WorldWideScience

Sample records for methods twenty-two eyes

  1. Comparison of two methods for composite score generation in dry eye syndrome.

    Science.gov (United States)

    See, Craig; Bilonick, Richard A; Feuer, William; Galor, Anat

    2013-09-19

    To compare two methods of composite score generation in dry eye syndrome (DES). Male patients seen in the Miami Veterans Affairs eye clinic with normal eyelid, corneal, and conjunctival anatomy were recruited to participate in the study. Patients filled out the Dry Eye Questionnaire 5 (DEQ5) and underwent measurement of tear film parameters. DES severity scores were generated by independent component analysis (ICA) and latent class analysis (LCA). A total of 247 men were included in the study. Mean age was 69 years (SD 9). Using ICA analysis, osmolarity was found to carry the largest weight, followed by eyelid vascularity and meibomian orifice plugging. Conjunctival injection and tear breakup time (TBUT) carried the lowest weights. Using LCA analysis, TBUT was found to be best at discriminating healthy from diseased eyes, followed closely by Schirmer's test. DEQ5, eyelid vascularity, and conjunctival injection were the poorest at discrimination. The adjusted correlation coefficient between the two generated composite scores was 0.63, indicating that the shared variance was less than 40%. Both ICA and LCA produced composite scores for dry eye severity, with weak to moderate agreement; however, agreement for the relative importance of single diagnostic tests was poor between the two methods.

  2. System and Method for Eye Tracking

    DEFF Research Database (Denmark)

    2017-01-01

    A method and system for monitoring the motion of one or both eyes, includes capturing a sequence of overlapping images of a subject's face including an eye and the corresponding non-eye region; identifying a plurality of keypoints in each image; mapping corresponding keypoints in two or more images...... of the sequence; assigning the keypoints to the eye and to the corresponding non-eye region; calculating individual velocities of the corresponding keypoints in the eye and the corresponding non-eye region to obtain a distribution of velocities; extracting at least one velocity measured for the eye and at least...... one velocity measured for the corresponding non-eye region; calculating the eye-in-head velocity for the eye based upon the measured velocity for the eye and the measured velocity for the corresponding non-eye region; and calculating the eye-in-head position based upon the eye- in-head velocity....

  3. Relationship between short-wavelength automatic perimetry and Heidelberg retina tomograph parameters in eyes with ocular hypertension

    Directory of Open Access Journals (Sweden)

    Christos Pitsas

    2015-10-01

    Full Text Available AIM:To compare and correlate optic nerve head parameters obtained byHeidelberg retina tomograph (HRT with short-wavelength automatic perimetry (SWAP indices in eyes with ocular hypertension (OHT.METHODS: One hundred and forty-six patients with OHT included in the present study. All subjects had reliable SWAP and HRT measurements performed within a 2wk period. The eyes were classified as normal/abnormal according to visual field criteria and Moorfields regression analysis (MRA. Correlations between visual field indices and HRT parameters were analyzed using Pearson correlation coefficient (r.RESULTS:Twenty-nine eyes (19.9% had SWAP defects. Twenty-nine eyes (19.9% were classified as abnormal according to global MRA. Six eyes (4.1% had abnormal global MRA and SWAP defects. The k statistic is 0.116 (P=0.12 indicating a very poor agreement between the methods. No statistical significant correlation between HRT and SWAP parameters was detected.CONCLUSION:SWAP defects may coexist with abnormalities of optic disc detected by HRT in eyes with OHT. In most eyes, however, the two methods detect different glaucoma properties.

  4. Aquaporins 6-12 in the human eye

    DEFF Research Database (Denmark)

    Tran, Thuy Linh; Bek, Toke; Holm, Lars

    2012-01-01

    Purpose: Aquaporins (AQPs) are widely expressed and have diverse distribution patterns in the eye. AQPs 0-5 have been localized at the cellular level in human eyes. We investigated the presence of the more recently discovered AQPs 6-12 in the human eye. Methods: RT-PCR was performed on fresh tissue...... from two human eyes divided into the cornea, corneal limbus, ciliary body and iris, lens, choroid, optic nerve, retina and sclera. Each structure was examined to detect the mRNA of AQPs 6-12. Twenty-one human eyes were examined using immunohistochemical and immunofluorescence techniques to determine...... was detected in the corneal epithelium, corneal endothelium, trabecular meshwork endothelium, ciliary epithelia, lens epithelium, the inner and outer limiting membrane of the retina, the retinal pigment epithelium and the capillary endothelium of all parts of the eye. AQP9 immunolabelling was detected...

  5. Eye movement perimetry in glaucoma.

    Science.gov (United States)

    Trope, G E; Eizenman, M; Coyle, E

    1989-08-01

    Present-day computerized perimetry is often inaccurate and unreliable owing to the need to maintain central fixation over long periods while repressing the normal response to presentation of peripheral stimuli. We tested a new method of perimetry that does not require prolonged central fixation. During this test eye movements were encouraged on presentation of a peripheral target. Twenty-three eyes were studied with an Octopus perimeter, with a technician monitoring eye movements. The sensitivity was 100% and the specificity 23%. The low specificity was due to the technician's inability to accurately monitor small eye movements in the central 6 degrees field. If small eye movements are monitored accurately with an eye tracker, eye movement perimetry could become an alternative method to standard perimetry.

  6. Study on the distribution of the dominant eye in people with myopia and astigmatism and the relationship between dominant eye and the two

    Directory of Open Access Journals (Sweden)

    Wen-Li Duan

    2015-11-01

    Full Text Available AIM:To study the distribution of the dominant eye in people with myopia and astigmatism and the relationship between dominant eye and the two. METHODS:Three hundred and eighty patients who went our hospital for optometry consecutively were enrolled, using hole-in-card method to detect the dominant eye. The records of age, gender, vision acuity and other related information were analyzed by SPSS 11.0 software. RESULTS: 1Most of the dominant eyes were right eyes which accounted for 66.84%, and the ametropia degree on right eyes was relatively higher; 2Dominant eyes had no significant association with gender, age and uncorrected vision acuity(P>0.05; 3There was no significant correlation between the dominant eyes and ametropia degree(P>0.05. But in the group which the difference of cylinder degree between two eyes were ≥1D, only 20% of the dominant eyes had higher ametropia degree, which was different from the other two groups. CONCLUSION:High cylinder of anisometropia may affect the choice of the dominant eye. High sphere of anisometropia may be the result of the choice of dominant eye.

  7. Genetic analyses of the human eye colours using a novel objective method for eye colour classification

    DEFF Research Database (Denmark)

    Andersen, Jeppe D.; Johansen, Peter; Harder, Stine

    2013-01-01

    In this study, we present a new objective method for measuring the eye colour on a continuous scale that allows researchers to associate genetic markers with different shades of eye colour. With the use of the custom designed software Digital Iris Analysis Tool (DIAT), the iris was automatically...... and TYR rs1393350) on the eye colour. We evaluated the two published prediction models for eye colour (IrisPlex [1] and Snipper[2]) and compared the predictions with the PIE-scores. We found good concordance with the prediction from individuals typed as HERC2 rs12913832 G. However, both methods had......-score ranged from −1 to 1 (brown to blue). The software eliminated the need for user based interpretation and qualitative eye colour categories. In 94% (570) of 605 analyzed eye images, the iris region was successfully extracted and a PIE-score was calculated. A very high correlation between the PIE...

  8. Red eyes in the necropsy floor: twenty cases of hyphema in dogs and cats

    Directory of Open Access Journals (Sweden)

    Tessie Beck Martins

    2015-01-01

    Full Text Available Hyphema (hemorrhage within the anterior chamber of the eye can be caused by several mechanisms and can easily be detected in routine ophthalmic or necroscopic examination as discolored red eye(s. The purpose of this study is to report the cause of hyphema diagnosed as a postmortem finding in dogs and cats. Twenty cases, 14 dogs and six cats of several ages and breeds and of both sexes were included in the study. Hyphema presented as a unilateral (14 cases out of 20 or bilateral (6/20 disorder in dogs and cats and extension of hemorrhage varied from minimal to diffuse. Hyphema was secondary to systemic disease (15/20 or occurred as a primary ocular lesion (5/20 in four dogs and one cat. Primary hyphema was always unilateral. In four of these cases, the cause of hyphema was trauma and remaining case was caused by phacoclastic uveitis in a dog with bilateral hypermature cataract. Various causes of bleeding disorders were found related to secondary hyphema: in decreasing order of frequency, they included vasculitis (8/15, systemic hypertension (5/15, and acquired coagulopathies (2/15. Vasculitis due to feline infectious peritonitis accounted for half of the cases (n=3 of systemic hyphema in cats. The various pathological aspects and pathogenesis of hyphema in dogs and cats are described and discussed.

  9. Staphylococcus aureus eye infections in two Indian hospitals: emergence of ST772 as a major clone

    Directory of Open Access Journals (Sweden)

    Nadig S

    2012-01-01

    Full Text Available Savitha Nadig1, Nithya Velusamy2, Prajna Lalitha2, Sarita Kar3, Savitri Sharma3, Gayathri Arakere11Society for Innovation and Development, Indian Institute of Science, Bengaluru, Karnataka, 2Aravind Eye Hospital, Madurai, Tamil Nadu, 3LV Prasad Eye Institute, Bhubaneswar, Odisha, IndiaPurpose: The purpose of this study was to perform molecular characterization of Staphylococcus aureus isolates causing a variety of eye infections from two major eye care hospitals in India.Methods: Twenty-four isolates from Aravind Eye Hospital, Madurai, India, and nine isolates from LV Prasad Eye Institute, Bhubaneswar, India, representing severe to nonsevere eye infections like microbial keratitis to lacrimal sac abscess, were characterized. Staphylococcal cassette chromosome mec typing, multilocus sequence typing, accessory gene regulator typing, staphylococcal protein A typing, and pulsed field gel electrophoresis were used, along with determination of the presence of Panton–Valentine leucocidin toxin and endotoxin gene cluster among each sequence type.Results: The majority of eye infections, both severe and nonsevere, were caused by sequence type (ST772, positive for the Panton–Valentine leucocidin gene, and carrying methicillin-resistant staphylococcal cassette chromosome mec type V cassette (22/33, 67%. Some of the other sequence types that caused severe eye infections were ST1 (9%, 5 (3%, 72 (6%, 88 (3%, 121 (3%, and 672 (3%. This is the first report of the presence of ST1 and 88 in India.Conclusion: Although the number of isolates included in this study was small, most of the eye infections were caused by community-associated S. aureus where patients had no history of hospitalization or treatment in the past year. In the case of six severe infections, patients were admitted for surgeries and there is probability of hospital infection. In addition, only methicillin-resistant S. aureus isolates carrying staphylococcal cassette chromosome mec type V were

  10. New Eye Cleansing Product Improves Makeup-Related Ocular Problems.

    Science.gov (United States)

    Okura, Masako; Kawashima, Motoko; Katagiri, Mikiyuki; Shirasawa, Takuji; Tsubota, Kazuo

    2015-01-01

    Purpose. This study evaluated the effects of using a newly developed eye cleansing formulation (Eye Shampoo) to cleanse the eyelids for 4 weeks in a parallel-group comparative study in women with chronic eye discomfort caused by heavy use of eye makeup and poor eye hygiene habits. Methods. Twenty women participants who met the inclusion criteria were randomly allocated to 2 groups comprising 10 participants each. The participants were asked to use either artificial tears alone or artificial tears in conjunction with Eye Shampoo for 4 weeks. The participants answered the questionnaire again and were reexamined, and changes in symptoms within each group and variations of symptoms between the two groups were statistically analyzed. Results. In the group using only artificial tears, improvements in subjective symptoms but not in ophthalmologic examination results were found. In the group using Eye Shampoo together with artificial tears, significant improvements were observed in the subjective symptoms, meibomian orifice obstruction, meibum secretion, tear breakup time, and superficial punctate keratopathy. Conclusion. In patients with chronic eye discomfort thought to be caused by heavy eye makeup, maintaining eyelid hygiene using Eye Shampoo caused a marked improvement in meibomian gland blockage and dry eye symptoms.

  11. A Novel Eye-Tracking Method to Assess Attention Allocation in Individuals with and without Aphasia Using a Dual-Task Paradigm

    Science.gov (United States)

    Heuer, Sabine; Hallowell, Brooke

    2015-01-01

    Numerous authors report that people with aphasia have greater difficulty allocating attention than people without neurological disorders. Studying how attention deficits contribute to language deficits is important. However, existing methods for indexing attention allocation in people with aphasia pose serious methodological challenges. Eye-tracking methods have great potential to address such challenges. We developed and assessed the validity of a new dual-task method incorporating eye tracking to assess attention allocation. Twenty-six adults with aphasia and 33 control participants completed auditory sentence comprehension and visual search tasks. To test whether the new method validly indexes well-documented patterns in attention allocation, demands were manipulated by varying task complexity in single- and dual-task conditions. Differences in attention allocation were indexed via eye-tracking measures. For all participants significant increases in attention allocation demands were observed from single- to dual-task conditions and from simple to complex stimuli. Individuals with aphasia had greater difficulty allocating attention with greater task demands. Relationships between eye-tracking indices of comprehension during single and dual tasks and standardized testing were examined. Results support the validity of the novel eye-tracking method for assessing attention allocation in people with and without aphasia. Clinical and research implications are discussed. PMID:25913549

  12. Wavefront Derived Refraction and Full Eye Biometry in Pseudophakic Eyes.

    Directory of Open Access Journals (Sweden)

    Xinjie Mao

    Full Text Available To assess wavefront derived refraction and full eye biometry including ciliary muscle dimension and full eye axial geometry in pseudophakic eyes using spectral domain OCT equipped with a Shack-Hartmann wavefront sensor.Twenty-eight adult subjects (32 pseudophakic eyes having recently undergone cataract surgery were enrolled in this study. A custom system combining two optical coherence tomography systems with a Shack-Hartmann wavefront sensor was constructed to image and monitor changes in whole eye biometry, the ciliary muscle and ocular aberration in the pseudophakic eye. A Badal optical channel and a visual target aligning with the wavefront sensor were incorporated into the system for measuring the wavefront-derived refraction. The imaging acquisition was performed twice. The coefficients of repeatability (CoR and intraclass correlation coefficient (ICC were calculated.Images were acquired and processed successfully in all patients. No significant difference was detected between repeated measurements of ciliary muscle dimension, full-eye biometry or defocus aberration. The CoR of full-eye biometry ranged from 0.36% to 3.04% and the ICC ranged from 0.981 to 0.999. The CoR for ciliary muscle dimensions ranged from 12.2% to 41.6% and the ICC ranged from 0.767 to 0.919. The defocus aberrations of the two measurements were 0.443 ± 0.534 D and 0.447 ± 0.586 D and the ICC was 0.951.The combined system is capable of measuring full eye biometry and refraction with good repeatability. The system is suitable for future investigation of pseudoaccommodation in the pseudophakic eye.

  13. New Eye Cleansing Product Improves Makeup-Related Ocular Problems

    Directory of Open Access Journals (Sweden)

    Masako Okura

    2015-01-01

    Full Text Available Purpose. This study evaluated the effects of using a newly developed eye cleansing formulation (Eye Shampoo to cleanse the eyelids for 4 weeks in a parallel-group comparative study in women with chronic eye discomfort caused by heavy use of eye makeup and poor eye hygiene habits. Methods. Twenty women participants who met the inclusion criteria were randomly allocated to 2 groups comprising 10 participants each. The participants were asked to use either artificial tears alone or artificial tears in conjunction with Eye Shampoo for 4 weeks. The participants answered the questionnaire again and were reexamined, and changes in symptoms within each group and variations of symptoms between the two groups were statistically analyzed. Results. In the group using only artificial tears, improvements in subjective symptoms but not in ophthalmologic examination results were found. In the group using Eye Shampoo together with artificial tears, significant improvements were observed in the subjective symptoms, meibomian orifice obstruction, meibum secretion, tear breakup time, and superficial punctate keratopathy. Conclusion. In patients with chronic eye discomfort thought to be caused by heavy eye makeup, maintaining eyelid hygiene using Eye Shampoo caused a marked improvement in meibomian gland blockage and dry eye symptoms.

  14. Post-destructive eye surgery, associated depression at Sekuru Kaguvi Hospital Eye Unit, Zimbabwe: Pilot Study

    Directory of Open Access Journals (Sweden)

    M. M. Kawome

    2013-12-01

    Full Text Available Destructive eye surgery is associated with more complications than just loss of visual functions of the eye and aesthetics. Currently there is very little published literature on post-destructive eye surgery associated depression. Zimbabwe has been experiencing a surge in the rate of destructive eye surgery done at the National Tertiary Eye Unit. This situation could be churning out lots of unrecognized depressed clients into the community who require assistance in one form or another. Objectives: To determine the prevalence of post-destructive eye surgery associated depression among patients attending Sekuru Kaguvi Hospital Eye Unit and assess if the current management protocol of patients undergoing destructive eye surgery at the Eye Unit addresses the problem adequately. Methods: A cross-sectional study of 28 randomly selected patients who had destructive eye surgeries at Sekuru Kaguvi Hospital was conducted over five months from 1st March 2012 to end of July 2012. A structured questionnaire containing 15 questions on the following items: gender, age, diagnosis, surgical procedure done, expectations before and after surgery, adequacy of counseling given and involvement of family was used to collect data. Nine questions to assess depression were adapted from the Patient Health Questionnaire (PHQ-9. Setting:  The study was conducted at SekuruKaguvi Hospital Eye Unit, Parirenyatwa Group of Hospitals in Harare. Results:  Twenty-eight patients who underwent destructive eye surgery during the study period were selected using systematic random sampling. The gender ratio was 1:1 and the mean age was 38.7 years with a range from 24 to 65 years. Fifty percent of the patients in the study had orbital exenteration while the rest had enucleation (14% and evisceration (36%. Twenty-eight percent of the study population had depression. Conclusion: Destructive eye surgery is frequently associated with depression and our current management protocol of

  15. Data eye monitor method and apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Gara, Alan G [Mount Kisco, NY; Marcella, James A [Rochester, MN; Ohmacht, Martin [Yorktown Heights, NY

    2012-01-31

    An apparatus and method for providing a data eye monitor. The data eye monitor apparatus utilizes an inverter/latch string circuit and a set of latches to save the data eye for providing an infinite persistent data eye. In operation, incoming read data signals are adjusted in the first stage individually and latched to provide the read data to the requesting unit. The data is also simultaneously fed into a balanced XOR tree to combine the transitions of all incoming read data signals into a single signal. This signal is passed along a delay chain and tapped at constant intervals. The tap points are fed into latches, capturing the transitions at a delay element interval resolution. Using XORs, differences between adjacent taps and therefore transitions are detected. The eye is defined by segments that show no transitions over a series of samples. The eye size and position can be used to readjust the delay of incoming signals and/or to control environment parameters like voltage, clock speed and temperature.

  16. Differences of accommodative responses between two eyes under binocular viewing condition mediated by polarizing glasses

    Directory of Open Access Journals (Sweden)

    Rui-Qing Wang

    2016-04-01

    Full Text Available AIM:To study the differences of accommodative responses between the two eyes under 3 different polarized viewing conditions. METHODS:Fifteen volunteers with emmetrope were recruited into this study(aged 18~38, 6 males and 9 females. Three different viewing conditions were set up by using polarizing glasses and liquid crystal display:(1right eye could see the visual target on the screen, but left eye cannot see it;(2left eye could see the visual target on the screen, but right eye cannot see it;(3both eyes could see the target. Accommodative responses were measured by infrared auto-refractor when fixating at the target at 5, 2, 1, 0.5 and 0.33m under the above 3 viewing conditions. The differences of accommodative responses under different viewing conditions were compared by using variance analysis of repeated measuring and t test. RESULTS:Significant differences of accommodative responses between the two eyes were found under condition(1and(2at all the fixating distance. The accommodative responses in used eyes which can see the visual target were higher than in non-used eyes which cannot see the visual target(PP>0.05. CONCLUSION:Ciliary muscles in the used eyes were more relatively tonic than non-used eyes under binocular open viewing condition. The imbalance of accommodative responses between two eyes may be one of the risk factors resulting into the occurrence of myopia.

  17. Systems and methods of eye tracking calibration

    DEFF Research Database (Denmark)

    2014-01-01

    Methods and systems to facilitate eye tracking control calibration are provided. One or more objects are displayed on a display of a device, where the one or more objects are associated with a function unrelated to a calculation of one or more calibration parameters. The one or more calibration...... parameters relate to a calibration of a calculation of gaze information of a user of the device, where the gaze information indicates where the user is looking. While the one or more objects are displayed, eye movement information associated with the user is determined, which indicates eye movement of one...... or more eye features associated with at least one eye of the user. The eye movement information is associated with a first object location of the one or more objects. The one or more calibration parameters are calculated based on the first object location being associated with the eye movement information....

  18. Long-term visual results in eyes cured for retinoblastoma by radiation

    International Nuclear Information System (INIS)

    Holbek, S.; Ehlers, N.

    1989-01-01

    Twenty-four eyes from 18 patients cured for retinoblastoma by radiation on an average 12 years previously, were re-examined with respect to visual performance. The macular functions, i.e. visual acuity, colour vision and contrast sensitivity demonstrated performances predictable from tumour localization and radiation dose to the macula. The rod functions, i.e. visual field and dark adaptation were found to be relatively resistant to the radiation treatment. A special problem encountered in two-eyed patients was the unavoidable amblyopia dut to unequal handicaps in the two eyes at the vulnerable age. (author)

  19. Long-term visual results in eyes cured for retinoblastoma by radiation

    Energy Technology Data Exchange (ETDEWEB)

    Holbek, S.; Ehlers, N. (Department of Ophthalmology, Aarhus University Hospital, Aarhus (Denmark))

    1989-01-01

    Twenty-four eyes from 18 patients cured for retinoblastoma by radiation on an average 12 years previously, were re-examined with respect to visual performance. The macular functions, i.e. visual acuity, colour vision and contrast sensitivity demonstrated performances predictable from tumour localization and radiation dose to the macula. The rod functions, i.e. visual field and dark adaptation were found to be relatively resistant to the radiation treatment. A special problem encountered in two-eyed patients was the unavoidable amblyopia dut to unequal handicaps in the two eyes at the vulnerable age. (author).

  20. Simplifying numerical ray tracing for two-dimensional non circularly symmetric models of the human eye.

    Science.gov (United States)

    Jesus, Danilo A; Iskander, D Robert

    2015-12-01

    Ray tracing is a powerful technique to understand the light behavior through an intricate optical system such as that of a human eye. The prediction of visual acuity can be achieved through characteristics of an optical system such as the geometrical point spread function. In general, its precision depends on the number of discrete rays and the accurate surface representation of each eye's components. Recently, a method that simplifies calculation of the geometrical point spread function has been proposed for circularly symmetric systems [Appl. Opt.53, 4784 (2014)]. An extension of this method to 2D noncircularly symmetric systems is proposed. In this method, a two-dimensional ray tracing procedure for an arbitrary number of surfaces and arbitrary surface shapes has been developed where surfaces, rays, and refractive indices are all represented in functional forms being approximated by Chebyshev polynomials. The Liou and Brennan anatomically accurate eye model has been adapted and used for evaluating the method. Further, real measurements of the anterior corneal surface of normal, astigmatic, and keratoconic eyes were substituted for the first surface in the model. The results have shown that performing ray tracing, utilizing the two-dimensional Chebyshev function approximation, is possible for noncircularly symmetric models, and that such calculation can be performed with a newly created Chebfun toolbox.

  1. Optics of the human cornea influence the accuracy of stereo eye-tracking methods: a simulation study.

    Science.gov (United States)

    Barsingerhorn, A D; Boonstra, F N; Goossens, H H L M

    2017-02-01

    Current stereo eye-tracking methods model the cornea as a sphere with one refractive surface. However, the human cornea is slightly aspheric and has two refractive surfaces. Here we used ray-tracing and the Navarro eye-model to study how these optical properties affect the accuracy of different stereo eye-tracking methods. We found that pupil size, gaze direction and head position all influence the reconstruction of gaze. Resulting errors range between ± 1.0 degrees at best. This shows that stereo eye-tracking may be an option if reliable calibration is not possible, but the applied eye-model should account for the actual optics of the cornea.

  2. MR-eyetracker: a new method for eye movement recording in functional magnetic resonance imaging.

    Science.gov (United States)

    Kimmig, H; Greenlee, M W; Huethe, F; Mergner, T

    1999-06-01

    We present a method for recording saccadic and pursuit eye movements in the magnetic resonance tomograph designed for visual functional magnetic resonance imaging (fMRI) experiments. To reliably classify brain areas as pursuit or saccade related it is important to carefully measure the actual eye movements. For this purpose, infrared light, created outside the scanner by light-emitting diodes (LEDs), is guided via optic fibers into the head coil and onto the eye of the subject. Two additional fiber optical cables pick up the light reflected by the iris. The illuminating and detecting cables are mounted in a plastic eyepiece that is manually lowered to the level of the eye. By means of differential amplification, we obtain a signal that covaries with the horizontal position of the eye. Calibration of eye position within the scanner yields an estimate of eye position with a resolution of 0.2 degrees at a sampling rate of 1000 Hz. Experiments are presented that employ echoplanar imaging with 12 image planes through visual, parietal and frontal cortex while subjects performed saccadic and pursuit eye movements. The distribution of BOLD (blood oxygen level dependent) responses is shown to depend on the type of eye movement performed. Our method yields high temporal and spatial resolution of the horizontal component of eye movements during fMRI scanning. Since the signal is purely optical, there is no interaction between the eye movement signals and the echoplanar images. This reasonably priced eye tracker can be used to control eye position and monitor eye movements during fMRI.

  3. Clinical Characteristics of Dry Eye Patients With Chronic Pain Syndromes

    NARCIS (Netherlands)

    Vehof, Jelle; Smitt-Kamminga, Nicole Sillevis; Kozareva, Diana; Nibourg, Simone A.; Hammond, Christopher J.

    PURPOSE: To investigate clinical characteristics of dry eye disease (DED) patients with a chronic pain syndrome. DESIGN: Cross-sectional. study. METHODS: Four hundred twenty-five patients of a tertiary care DED patient cohort in the Netherlands were included. Chronic pain syndromes irritable bowel

  4. Rapid assessment methods in eye care: An overview

    Directory of Open Access Journals (Sweden)

    Srinivas Marmamula

    2012-01-01

    Full Text Available Reliable information is required for the planning and management of eye care services. While classical research methods provide reliable estimates, they are prohibitively expensive and resource intensive. Rapid assessment (RA methods are indispensable tools in situations where data are needed quickly and where time- or cost-related factors prohibit the use of classical epidemiological surveys. These methods have been developed and field tested, and can be applied across almost the entire gamut of health care. The 1990s witnessed the emergence of RA methods in eye care for cataract, onchocerciasis, and trachoma and, more recently, the main causes of avoidable blindness and visual impairment. The important features of RA methods include the use of local resources, simplified sampling methodology, and a simple examination protocol/data collection method that can be performed by locally available personnel. The analysis is quick and easy to interpret. The entire process is inexpensive, so the survey may be repeated once every 5-10 years to assess the changing trends in disease burden. RA survey methods are typically linked with an intervention. This article provides an overview of the RA methods commonly used in eye care, and emphasizes the selection of appropriate methods based on the local need and context.

  5. Effects of megavoltage therapy of cancer on the eye

    International Nuclear Information System (INIS)

    Nordman, E.; Nordman, L.E.O.; Voutilainen, A.; Turku Univ.

    1976-01-01

    Twenty-two cases with carcinomas of the nasal cavity, sinuses, buccal and orbital regions treated in the Radiotherapy Clinic of University Central Hospital in Turku, are presented. The dose delivered to the eye was 1,400 to 6,300 rd. The most usual radiation complication was keratitis which appeared in 15 cases, cataract was diagnosed in seven cases, corneal ulcer in three, iritis in two, retinopathia in two, and glaucoma in three cases. Most of the complications could be relieved or cured with appropriate therapy. In only one case the eye was to be enucleated because of severe glaucoma and corneal ulceration. As the prognosis of malignant tumours in this area usually is bad, irradiation to the eye on the affected side is to be taken as a calculated risk to achieve a more effective cancer control. (orig.) [de

  6. Novel method for evaluation of eye movements in patients with narcolepsy

    DEFF Research Database (Denmark)

    Christensen, Julie A E; Kempfner, Lykke; Leonthin, Helle L

    2017-01-01

    BACKGROUND: Narcolepsy causes abnormalities in the control of wake-sleep, non-rapid-eye-movement (non-REM) sleep and REM sleep, which includes specific eye movements (EMs). In this study, we aim to evaluate EM characteristics in narcolepsy as compared to controls using an automated detector....... RESULTS: NT1 patients had significantly less EMs during wake, N1, and N2 sleep and more EMs during REM sleep compared to clinical controls, and significantly less EMs during wake and N1 sleep compared to NT2 patients. Furthermore, NT1 patients showed less EMs during NREM sleep in the first sleep cycle....... METHODS: We developed a data-driven method to detect EMs during sleep based on two EOG signals recorded as part of a polysomnography (PSG). The method was optimized using the manually scored hypnograms from 36 control subjects. The detector was applied on a clinical sample with subjects suspected...

  7. Optics of the human cornea influence the accuracy of stereo eye-tracking methods: a simulation study

    NARCIS (Netherlands)

    Barsingerhorn, A.D.; Boonstra, F.N.; Goossens, H.H.L.M.

    2017-01-01

    Current stereo eye-tracking methods model the cornea as a sphere with one refractive surface. However, the human cornea is slightly aspheric and has two refractive surfaces. Here we used ray-tracing and the Navarro eye-model to study how these optical properties affect the accuracy of different

  8. Localized whole eye radiotherapy for retinoblastoma using a 125I applicator, 'claws'

    International Nuclear Information System (INIS)

    Stannard, Clare; Sealy, Rossall; Hering, Egbert; Korrubel, Jan; Hill, John; Barron, Adrian; Knowles, Ruth

    2001-01-01

    Purpose: To treat children with retinoblastoma, who require whole eye radiotherapy, with a specially designed 125 I applicator that irradiates the eye while sparing the surrounding tissues. Methods and Materials: Under general anesthesia, a pericorneal ring is attached to the 4 extraocular muscles, and 4 appendages, each loaded with 125 I seeds, are inserted beneath the conjunctiva in-between each pair of muscles and attached anteriorly to the ring. Twenty-nine eyes were treated. Eighteen received a median dose of 28 Gy during 91 hours and 11 received 40 Gy during 122 hours, when the relative biologic effectiveness was taken as 1 instead of 1.5. Six had received prior chemotherapy. Results: Twenty-four eyes were followed up for 2-157 months (median 29). Although 22 eyes responded, local control was achieved in 13 patients, 3 of whom required additional treatment for new tumors; a further 3 required additional treatment for tumor recurrence as well as new tumors. One of these eyes was enucleated for neovascular glaucoma. All 6 Group I-III eyes and 6 of 18 Group V eyes were retained for 2-157 months (median 39), with good vision in 10 eyes. Three developed cataracts 7, 8, and 12 years later, 1 of which has been removed. Conclusions: This is a new way of irradiating the whole eye with a minimal dose to the surrounding tissues. The treatment time is only 5 days. It is effective in Groups I-III, but only 33% of Group V eyes retained vision. No late cosmetic defects occurred

  9. A novel evaluation of two related and two independent algorithms for eye movement classification during reading.

    Science.gov (United States)

    Friedman, Lee; Rigas, Ioannis; Abdulin, Evgeny; Komogortsev, Oleg V

    2018-05-15

    Nystrӧm and Holmqvist have published a method for the classification of eye movements during reading (ONH) (Nyström & Holmqvist, 2010). When we applied this algorithm to our data, the results were not satisfactory, so we modified the algorithm (now the MNH) to better classify our data. The changes included: (1) reducing the amount of signal filtering, (2) excluding a new type of noise, (3) removing several adaptive thresholds and replacing them with fixed thresholds, (4) changing the way that the start and end of each saccade was determined, (5) employing a new algorithm for detecting PSOs, and (6) allowing a fixation period to either begin or end with noise. A new method for the evaluation of classification algorithms is presented. It was designed to provide comprehensive feedback to an algorithm developer, in a time-efficient manner, about the types and numbers of classification errors that an algorithm produces. This evaluation was conducted by three expert raters independently, across 20 randomly chosen recordings, each classified by both algorithms. The MNH made many fewer errors in determining when saccades start and end, and it also detected some fixations and saccades that the ONH did not. The MNH fails to detect very small saccades. We also evaluated two additional algorithms: the EyeLink Parser and a more current, machine-learning-based algorithm. The EyeLink Parser tended to find more saccades that ended too early than did the other methods, and we found numerous problems with the output of the machine-learning-based algorithm.

  10. Pseudoexfoliation syndrome at a Singapore eye clinic

    Directory of Open Access Journals (Sweden)

    Lee JK

    2015-09-01

    Full Text Available Jason Kian Seng Lee, Elizabeth Poh Ying Wong, Su Ling HoNational Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore Background: The purpose of this study was to investigate the demographics of pseudoexfoliation syndrome (PXF and pseudoexfoliative glaucoma (PXG in a Singapore hospital eye outpatient clinic.Methods: A retrospective study of 93 consecutive patients (146 eyes with PXF was undertaken by a single ophthalmologist over a period of 37 months (July 1, 2006, to July 31, 2009.Results: Ninety-three (2.8% of 3,297 patients seen during the study period were diagnosed with PXF. Forty-three (46.2% of the 93 PXF patients were male. Indians were 5.04 times more likely to develop PXF than Chinese (P<0.001, 95% confidence interval 3.05–8.33, while Malays were 2.22 times more likely to develop PXF as compared with Chinese (P=0.029, 95% CI 1.08–4.55. Twenty-two (23.7% of the 93 PXF patients had PXG at the time of diagnosis. There was no statistically significant difference in mean age between PXF and PXG patients. There was a larger proportion of males with PXG than females (P<0.001.Conclusion: PXF is not infrequent in elderly Singapore eye clinic patients, and is more likely to occur in Indians than in Chinese. In the Singapore eye clinic setting, males may be more likely to develop PXG, although larger studies will be required to confirm this.Keywords: exfoliation syndrome, pseudoexfoliation syndrome, exfoliation glaucoma, glaucoma capsulare

  11. Clinical observation of two operation methods for neovascular glaucoma

    Directory of Open Access Journals (Sweden)

    Peng Zhang

    2013-11-01

    Full Text Available AIM: To evaluate the clinical effect of two different surgical treatments for neovascular glaucoma(NVG.METHODS: A total of 30 NVG inpatients(30 eyesat our hospital from April 2008 to December 2011 were reviewed. Patients were divided into two groups according to the different surgical treatments. In group A, 12 cases(12 eyeswere treated with Ahmed glaucoma valve(AGVimplantation and in group B, 18 cases(18 eyeswere treated with semiconductor diode laser photocoagulation transscleral cyclophotocoagulation(TSCPC. Intraocular pressure, visual acuity and complications were compared between two groups postoperatively.RESULTS: The postoperative IOP was significantly lower in each group(PPP>0.05in IOP 1 month after surgery. Visual acuity: in group A, the visual acuity was improved in 3 eyes, unchanged in 7 eyes and worsened in 2 eyes.; in group B, the visual acuity was improved in 3 eyes, unchanged in 12 eyes and worsened in 3 eyes. Postoperative complications: in group A, eyeball pain and corneal edema were found in 5 cases(41.7%, shallow anterior chamber in 3 cases(25%, anterior chamber fibroid exudation in 2 cases(16.7%, hyphema in 3 cases(25%; in group B, eyeball pain atearly stage after surgery were found in 10 cases(55.6% , corneal edema in 11 cases(61.1%, anterior chamber fibroid exudation in 5 cases(27.8%, hyphema in 6 cases(33.3%.CONCLUSION: AGV implantation and TSCPC are both effective surgical treatment methods for NVG. AGV implantation is a filtration surgery, which is relatively safe. TSCPC is more economical and suitable for glaucoma of advanced or absolute stage.

  12. Treatment of contact lens related dry eye with antibacterial honey.

    Science.gov (United States)

    Wong, Daniel; Albietz, Julie M; Tran, Huan; Du Toit, Cimonette; Li, Anita Hui; Yun, Tina; Han, Jee; Schmid, Katrina L

    2017-12-01

    Contact lens induced dry eye affects approximately 50% of contact lens wearers. The aim was to assess the effects of Manuka (Leptospermum sp.) honey eye drops (Optimel, Melcare, Australia) on dry eye in contact lens wearers. The safety of the honey eye drops in contact lens wear and contact lens wearers' compliance were also evaluated. Prospective, randomised, cross over study, examiner masked, pilot treatment trial. Twenty-four participants aged 20 to 55 years with contact lens related dry eye were recruited and randomised to two treatment groups; 20 completed the study. One group used Optimel eye drops twice a day for two weeks followed by conventional lubricant (Systane Ultra, Alcon) therapy for two weeks; the other group completed the treatments in the reverse order. Before and after each treatment dry eye symptomology, ocular surface inflammation, and tear quantity and quality were assessed. Participants completed a daily log detailing their usage of treatments and any issues. Dry eye symptoms improved significantly after Optimel treatment. Patients with more severe symptoms at baseline showed a greater improvement in symptoms. No significant differences were observed in the objective signs of dry eye; presumably because of the short treatment duration. Seventy-five% of contact lens wearers reported good adherence to Optimel treatment and 95% reported no issues using this product. Optimel Eye Drops reduce the symptoms of dry eye in contact lens wearers and are safe to use. A longer treatment period to assess the effect on clinical signs of dry eye is required. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  13. Two-Laser Interference Visible to the Naked Eye

    Science.gov (United States)

    Kawalec, Tomasz; Bartoszek-Bober, Dobroslawa

    2012-01-01

    An experimental setup allowing the observation of two-laser interference by the naked eye is described. The key concept is the use of an electronic phase lock between two external cavity diode lasers. The experiment is suitable both for undergraduate and graduate students, mainly in atomic physics laboratories. It gives an opportunity for…

  14. Two-Photon Autofluorescence Imaging Reveals Cellular Structures Throughout the Retina of the Living Primate Eye.

    Science.gov (United States)

    Sharma, Robin; Williams, David R; Palczewska, Grazyna; Palczewski, Krzysztof; Hunter, Jennifer J

    2016-02-01

    Although extrinsic fluorophores can be introduced to label specific cell types in the retina, endogenous fluorophores, such as NAD(P)H, FAD, collagen, and others, are present in all retinal layers. These molecules are a potential source of optical contrast and can enable noninvasive visualization of all cellular layers. We used a two-photon fluorescence adaptive optics scanning light ophthalmoscope (TPF-AOSLO) to explore the native autofluorescence of various cell classes spanning several layers in the unlabeled retina of a living primate eye. Three macaques were imaged on separate occasions using a custom TPF-AOSLO. Two-photon fluorescence was evoked by pulsed light at 730 and 920 nm excitation wavelengths, while fluorescence emission was collected in the visible range from several retinal layers and different locations. Backscattered light was recorded simultaneously in confocal modality and images were postprocessed to remove eye motion. All retinal layers yielded two-photon signals and the heterogeneous distribution of fluorophores provided optical contrast. Several structural features were observed, such as autofluorescence from vessel walls, Müller cell processes in the nerve fibers, mosaics of cells in the ganglion cell and other nuclear layers of the inner retina, as well as photoreceptor and RPE layers in the outer retina. This in vivo survey of two-photon autofluorescence throughout the primate retina demonstrates a wider variety of structural detail in the living eye than is available through conventional imaging methods, and broadens the use of two-photon imaging of normal and diseased eyes.

  15. Twenty lectures on thermodynamics

    CERN Document Server

    Buchdahl, H A

    2013-01-01

    Twenty Lectures on Thermodynamics is a course of lectures, parts of which the author has given various times over the last few years. The book gives the readers a bird's eye view of phenomenological and statistical thermodynamics. The book covers many areas in thermodynamics such as states and transition; adiabatic isolation; irreversibility; the first, second, third and Zeroth laws of thermodynamics; entropy and entropy law; the idea of the application of thermodynamics; pseudo-states; the quantum-static al canonical and grand canonical ensembles; and semi-classical gaseous systems. The text

  16. Practical Use of the Eye Camera in Pedagogical Research (Processing of Selected Data Using the Eye Tracking Method

    Directory of Open Access Journals (Sweden)

    Škrabánková Jana

    2016-06-01

    Full Text Available The paper deals with author’s pilot experiments using the eye tracking method for the primary school children examination. This method enables to gain a large amount of research data based on the tested people’s eye movements monitoring. In the paper, there are processed chosen research data of four gifted students’ examination in the context of their mathematical and logical intelligence.

  17. Hand-Eye LRF-Based Iterative Plane Detection Method for Autonomous Robotic Welding

    Directory of Open Access Journals (Sweden)

    Sungmin Lee

    2015-12-01

    Full Text Available This paper proposes a hand-eye LRF-based (laser range finder welding plane-detection method for autonomous robotic welding in the field of shipbuilding. The hand-eye LRF system consists of a 6 DOF manipulator and an LRF attached to the wrist of the manipulator. The welding plane is detected by the LRF with only the wrist's rotation to minimize a mechanical error caused by the manipulator's motion. A position on the plane is determined as an average position of the detected points on the plane, and a normal vector to the plane is determined by applying PCA (principal component analysis to the detected points. In this case, the accuracy of the detected plane is analysed by simulations with respect to the wrist's angle interval and the plane angle. As a result of the analysis, an iterative plane-detection method with the manipulator's alignment motion is proposed to improve the performance of plane detection. For verifying the feasibility and effectiveness of the proposed plane-detection method, experiments are carried out with a prototype of the hand-eye LRF-based system, which consists of a 1 DOF wrist's joint, an LRF system and a rotatable plane. In addition, the experimental results of the PCA-based plane detection method are compared with those of the two representative plane-detection methods, based on RANSAC (RANdom SAmple Consensus and the 3D Hough transform in both accuracy and computation time's points of view.

  18. Assessment of the Dutch organ-culture system of corneal preservation within the Eye Bank of South Australia.

    Science.gov (United States)

    Williams, K A; Noack, L M; Alfrich, S J; Danz, R; Erickson, S A; Coster, D J

    1988-02-01

    Thirteen per cent of all corneas harvested by the Eye Bank of South Australia during 1986 were discarded because storage time in McCarey-Kaufman medium exceeded four days. We have therefore examined the suitability of the Dutch method of long-term corneal storage for our purposes. Twenty-two human corneas that had been discarded from the Eye Bank were assessed using the trypan blue-sucrose staining technique, and then placed into long-term storage for 15 to 17 days. They were then reassessed by vital dye staining before permanent flat-mounts were prepared for silver staining of the endothelium. A good correlation (albeit subjective) was found between the non-destructive and destructive techniques of endothelial cell assessment. Those corneas that failed to survive organ culture storage were easily detected. The Dutch system of corneal preservation and post-storage assessment seems well-suited to Australian eye-banking.

  19. Enhancing Indigenous Health Promotion Research Through Two-Eyed Seeing: A Hermeneutic Relational Process.

    Science.gov (United States)

    Hovey, Richard B; Delormier, Treena; McComber, Alex M; Lévesque, Lucie; Martin, Debbie

    2017-07-01

    The intention of this article is to demonstrate how Indigenous and allied health promotion researchers learned to work together through a process of Two-Eyed Seeing. This process was first introduced as a philosophical hermeneutic research project on diabetes prevention within an Indigenous community in Quebec Canada. We, as a research team, became aware that hermeneutics and the principles of Haudenosaunee decision making were characteristic of Two-Eyed Seeing. This article describes our experiences while working with each other. Our learning from these interactions emphasized the relational aspects needed to ensure that we became a highly functional research team while working together and becoming Two-Eyed Seeing partners.

  20. Research on direct calibration method of eye-to-hand system of robot

    Science.gov (United States)

    Hu, Xiaoping; Xie, Ke; Peng, Tao

    2013-10-01

    In the position-based visual servoing control for robot, the hand-eye calibration is very important because it can affect the control precision of the system. According to the robot with eye-to-hand stereovision system, this paper proposes a direct method of hand-eye calibration. The method utilizes the triangle measuring principle to solve the coordinates in the camera coordinate system of scene point. It calculates the estimated coordinates by the hand-eye calibration equation set which indicates the transformational relation from the robot to the camera coordinate system, and then uses the error of actual and estimated coordinates to establish the objective function. Finally the method substitutes the parameters into the function repeatedly until it converged to optimize the result. The related experiment compared the measured coordinates with the actual coordinates, shows the efficiency and the precision of it.

  1. Changes of Corneal Wavefront Aberrations in Dry Eye Patients after Treatment with Artificial Lubricant Drops

    Directory of Open Access Journals (Sweden)

    Ning Lu

    2016-01-01

    Full Text Available Purpose. To evaluate the corneal aberration changes in dry eye patients after treatment with artificial eye drops. Methods. Thirty mild to moderate dry eye patients treated with artificial eye drops and twenty comparable dry eye patients were recruited as controls. Anterior corneal aberrations over 3 mm and 5 mm analytical zones including total, 3rd to 5th high order aberrations (HOAs, spherical aberration (SA, and vertical (V-coma and horizontal coma (H-coma obtained from corneal topography data at baseline and 2 weeks after treatment were evaluated. Results. For 3 mm zone, trefoils, V-coma, H-coma terms, and 3rd and 5th HOAs were significantly decreased (p0.05. Conclusions. Treatment with artificial eye drops can effectively improve the corneal optical quality of dry eye patients by ameliorating the HOAs of anterior corneal surface.

  2. An Assessment of Vitreous Degeneration in Eyes with Vitreomacular Traction and Macular Holes

    Directory of Open Access Journals (Sweden)

    Quraish Ghadiali

    2017-01-01

    Full Text Available Purpose. To compare the stages of vitreous degeneration in patients with vitreomacular traction (VMT and macular holes (MH. Methods. A retrospective study was performed analyzing stages of vitreous degeneration of eyes with VMT or MH using swept-source optical coherence tomography (SS-OCT and spectral-domain optical coherence tomography (SD-OCT. An analogous review was performed on a control group of eyes with contralateral posterior vitreous detachments. Thirty-four eyes with VMT/MH and 39 control eyes were reviewed. Results. Twenty-seven VMT/MH eyes and 31 control eyes were included. Eyes with VMT/MH demonstrated significantly earlier stages of vitreous degeneration when compared to the control group (p=0.048 despite significantly greater age (p=0.032. Conclusions. Vitreoretinal interface disease is more often associated with a formed vitreous and an intact premacular bursa. This is contrary to previous assumptions implicating degeneration of vitreous as a precipitating factor of interface disease when in conjunction with abnormal vitreomacular separation.

  3. The effect of vitamin A palmitate eye gel on ocular surface recovery after LASIK

    Directory of Open Access Journals (Sweden)

    Yan Lu

    2013-04-01

    Full Text Available AIM: To study the effect of vitamin A palmitate eye gel on ocular surface reconstruction after laser in situ keratomileusis(LASIK, and to evaluate the efficacy and safety. METHODS: One hundred and twenty patients(240 eyesperforming LASIK were enrolled in this study. The right and left eyes were randomly divided into experimental group and control group. The experimental group were treated with vitamin A palmitate eye gel for 1 month, four times a day after LASIK, and the same as control group in other treatments. The SchirmerⅠ test, break-up time(BUTand corneal sensation were detect at preoperation and the postoperative 1st day, 1st month, 3rd month in two groups. RESULTS: There were significant difference in BUT and tear secretion quantity between the experimental group and the control group at the postoperative 1st month and 3rd month(P0.05, which revealed that vitamin A palmitate eye gel had no obvious effect on recovery of corneal sensation after LASIK. During the treatment, there was no adverse drug event occurred. CONCLUSION: Early use of vitamin A palmitate eye gel postoperatively is applicable for ocular surface reconstruction, but has no obvious effect on the regeneration of corneal sensation.

  4. Expert System Diagnosis of Cataract Eyes Using Fuzzy Mamdani Method

    Science.gov (United States)

    Santosa, I.; Romla, L.; Herawati, S.

    2018-01-01

    Cataracts are eye diseases characterized by cloudy or opacity of the lens of the eye by changing the colour of black into grey-white which slowly continues to grow and develop without feeling pain and pain that can cause blindness in human vision. Therefore, researchers make an expert system of cataract eye disease diagnosis by using Fuzzy Mamdani and how to care. The fuzzy method can convert the crisp value to linguistic value by fuzzification and includes in the rule. So this system produces an application program that can help the public in knowing cataract eye disease and how to care based on the symptoms suffered. From the results of the design implementation and testing of expert system applications to diagnose eye disease cataracts, it can be concluded that from a trial of 50 cases of data, obtained test results accuracy between system predictions with expert predictions obtained a value of 78% truth.

  5. Two opsins from the compound eye of the crab Hemigrapsus sanguineus

    Science.gov (United States)

    Sakamoto; Hisatomi; Tokunaga; Eguchi

    1996-01-01

    The primary structures of two opsins from the brachyuran crab Hemigrapsus sanguineus were deduced from the cDNA nucleotide sequences. Both deduced proteins were composed of 377 amino acid residues and included residues highly conserved in visual pigments of other species, and the proteins were 75 % identical to each other. The distribution of opsin transcripts in the compound eye, determined by in situ hybridization, suggested that the mRNAs of the two opsins were expressed simultaneously in all of the seven retinular cells (R1-R7) forming the main rhabdom in each ommatidium. Two different visual pigments may be present in one photoreceptor cell in this brachyuran crab. The spectral sensitivity of the compound eye was also determined by recording the electroretinogram. The compound eye was maximally sensitive at about 480 nm. These and previous findings suggest that both opsins of this brachyuran crab produce visual pigments with maximal absorption in the blue-green region of the spectrum. Evidence is presented that crustaceans possess multiple pigment systems for vision.

  6. Lobster eye X-ray optics: Data processing from two 1D modules

    Science.gov (United States)

    Nentvich, O.; Urban, M.; Stehlikova, V.; Sieger, L.; Hudec, R.

    2017-07-01

    The X-ray imaging is usually done by Wolter I telescopes. They are suitable for imaging of a small part of the sky, not for all-sky monitoring. This monitoring could be done by a Lobster eye optics which can theoretically have a field of view up to 360 deg. All sky monitoring system enables a quick identification of source and its direction. This paper describes the possibility of using two independent one-dimensional Lobster Eye modules for this purpose instead of Wolter I and their post-processing into an 2D image. This arrangement allows scanning with less energy loss compared to Wolter I or two-dimensional Lobster Eye optics. It is most suitable especially for very weak sources.

  7. Images of photoreceptors in living primate eyes using adaptive optics two-photon ophthalmoscopy

    Science.gov (United States)

    Hunter, Jennifer J.; Masella, Benjamin; Dubra, Alfredo; Sharma, Robin; Yin, Lu; Merigan, William H.; Palczewska, Grazyna; Palczewski, Krzysztof; Williams, David R.

    2011-01-01

    In vivo two-photon imaging through the pupil of the primate eye has the potential to become a useful tool for functional imaging of the retina. Two-photon excited fluorescence images of the macaque cone mosaic were obtained using a fluorescence adaptive optics scanning laser ophthalmoscope, overcoming the challenges of a low numerical aperture, imperfect optics of the eye, high required light levels, and eye motion. Although the specific fluorophores are as yet unknown, strong in vivo intrinsic fluorescence allowed images of the cone mosaic. Imaging intact ex vivo retina revealed that the strongest two-photon excited fluorescence signal comes from the cone inner segments. The fluorescence response increased following light stimulation, which could provide a functional measure of the effects of light on photoreceptors. PMID:21326644

  8. Clinical effect observation of pranoprofen combined with deproteinized calf blood extract eye drops for moderate to severe dry eye

    Directory of Open Access Journals (Sweden)

    Jing-Hua Qiu

    2018-04-01

    Full Text Available AIM: To explore clinical effect of pranoprofen combined with deproteinized calf blood extract eye drops for moderate to severe dry eye. METHODS: A total of 84 patients(132 eyeswho received treatment at the Zhengzhou Second Hospital were selected from January 2016 to January 2017. According to random number table method they were divided into control group 42 cases(68 eyesand observation group 42 cases(64 eyes, the control group using polyvinyl alcohol eye drops with pranoprofen, observation group with pranoprofen with deproteinized extract of calf blood eye drops. Subjective and objective scores before and after treatment were recorded. RESULTS: There was no statistically significant difference on the four objective indicators of pretreatment FL, BUT, SⅠt, and vision between the two groups(P>0.05. Dry eye symptom scores of the two groups decreased after treatment, both with significantly different(PPPPCONCLUSION: The clinical effect of praprofen on the treatment of moderate to severe dry eye with the deproteinized calf blood extract is better.

  9. Eye tracking and the translation process

    DEFF Research Database (Denmark)

    Hvelplund, Kristian Tangsgaard

    2014-01-01

    Eye tracking has become increasingly popular as a quantitative research method in translation research. This paper discusses some of the major methodological issues involved in the use of eye tracking in translation research. It focuses specifically on challenges in the analysis and interpretation...... of eye-tracking data as reflections of cognitive processes during translation. Four types of methodological issues are discussed in the paper. The first part discusses the preparatory steps that precede the actual recording of eye-tracking data. The second part examines critically the general assumptions...... linking eye movements to cognitive processing in the context of translation research. The third part of the paper discusses two popular eye-tracking measures often used in translation research, fixations and pupil size, while the fourth part proposes a method to evaluate the quality of eye-tracking data....

  10. Outcome of surgery in post-cytomegalovirus retinal detachment: Experience before and in the era of highly active anti-retroviral therapy in Indian eyes

    Directory of Open Access Journals (Sweden)

    Ramandeep Singh

    2013-01-01

    Full Text Available Purpose: To evaluate the outcome of surgery for cytomegalovirus associated retinal detachment (CMVRD in human immunodeficiency virus (HIV-infected patients in pre-highly active antiretroviral therapy (HAART and HAART era in Indian eyes. Materials and Methods: Retrospective, we reviewed medical records of all consecutive HIV patients, who underwent surgical repair for CMVRD from July 1998 to June 2011. We divided patients into two groups, i.e. group 1, pre HAART era and group 2, HAART era. We compared two groups for various parameters like visual outcome, surgical success, additional procedures, follow-up, etc., Results: Twenty-eight eyes of 26 patients were included; 12 eyes of the 11 patients in group 1 and 16 eyes of the 15 patients in group 2. Significant visual acuity improvement was seen in both groups. Complete anatomic success was seen in 11 eyes in group 1 and 15 eyes in group 2. One additional procedure in group 1 and 29 additional procedures were done in group 2. A mean follow-up was 16 months in group 1 and 41 months in group 2. Conclusion: There was no difference in outcome in pre-HAART and HAART group, except for longer follow-up and additional surgical procedures in HAART group.

  11. Eye Movement Desensitization and Reprocessing (EMDR as a Neurorehabilitation Method

    Directory of Open Access Journals (Sweden)

    Afsaneh Zarghi

    2013-01-01

    Full Text Available   A variety of nervous system components such as medulla, pons, midbrain, cerebellum, basal ganglia, parietal, frontal and occipital lobes have role in Eye Movement Desensitization and Reprocessing (EMDR processes. The eye movement is done simultaneously for attracting client's attention to an external stimulus while concentrating on a certain internal subject. Eye movement guided by therapist is the most common attention stimulus. The role of eye movement has been documented previously in relation with cognitive processing mechanisms. A series of systemic experiments have shown that the eyes’ spontaneous movement is associated with emotional and cognitive changes and results in decreased excitement, flexibility in attention, memory processing, and enhanced semantic recalling. Eye movement also decreases the memory's image clarity and the accompanying excitement. By using EMDR, we can reach some parts of memory which were inaccessible before and also emotionally intolerable. Various researches emphasize on the effectiveness of EMDR in treating and curing phobias, pains, and dependent personality disorders. Consequently, due to the involvement of multiple neural system components, this palliative method of treatment can also help to rehabilitate the neuro-cognitive system.

  12. Vestibulo-tactile interactions regarding motion perception and eye movements in yaw

    NARCIS (Netherlands)

    Bos, J.E.; Erp, J.B.F. van; Groen, E.L.; Veen, H.J. van

    2005-01-01

    This paper shows that tactile stimulation can override vestibular information regarding spinning sensations and eye movements. However, we conclude that the current data do not support the hypothesis that tactile stimulation controls eye movements directly. To this end, twenty-four subjects were

  13. Effect of rb-bFGF eye drops and hydroxyl indican eye drops on tear film stability and dry eye symptoms after age-related cataract surgery

    Directory of Open Access Journals (Sweden)

    Yu Ling

    2018-01-01

    Full Text Available AIM: To investigate the effect of recombinant bovine basic fibroblast growth factor(rb-bFGFeye drops and hydroxyl indican eye drops on tear film stability and dry eye symptoms after age-related cataract surgery. METHODS: Totally 80 patients with 80 affected eyes undergoing age-related cataract surgery in our hospital from January 2015 to October 2016 were selected as study subjects, and they were randomly divided into control group and experimental group with 40 patients(40 affected eyesin each group. The two groups were treated with hydroxyl indican eye drops and rb-bFGF eye drops, respectively. The clinical curative effect, inflammation related factors \\〖interleukin 6(IL-6, tumor necrosis factor α(TNF-α\\〗, Schirmer test(SⅠt, break-up time(BUTof tear film, corneal sodium fluorescein staining(FLand scores of dry eye symptoms in the two groups were observed. RESULTS: The total treatment effective rate of experimental group after treatment was significantly higher than that of the control group(90.0% vs 72.5%; χ2=4.021, PP>0.05. After treatment, IL-6, TNF-α, SⅠt, FL score and scores of dry eye symptoms in two groups significantly decreased while BUT significantly increased(PPCONCLUSION: In the treatment of patients after age-related cataract after surgery, rb-bFGF eye drops has more advantages over hydroxyl indican eye drops in regulating the expression of inflammatory factors, improving the tear film stability and relieving dry eye symptoms.

  14. Aqueous proinflammatory cytokines in acute primary angle-closure eyes

    Directory of Open Access Journals (Sweden)

    Yao-Ming Liu

    2017-05-01

    Full Text Available AIM: To evaluate changes of proinflammatory cytokines in aqueous humor of patients with acute primary angle-closure (APAC and age-related cataracts. METHODS: Twenty eyes of 20 APAC patients and 15 eyes of 15 age-related cataract patients were included in this cross-sectional study. Aqueous humor samples were collected prospectively. The levels of 20 proinflammatory cytokines were evaluated in the aqueous humor of the APAC and cataract patients using the multiplex bead immunoassay technique. Clinical data were collected for correlation analysis. RESULTS: Seven of the 20 proinflammatory cytokines included in the magnetic bead panel were detectable in both APAC eyes and cataract eyes: interleukin (IL-10, IL-12, IL-15, IL-21, IL-6, chemokine (C-C motif ligand 20, and tumor necrosis factor alpha (TNF-α. IL-27 was only detectable in APAC eyes. Compared with the cataract eyes, the APAC eyes had significantly elevated concentrations of IL-12 (P=0.036, IL-15 (P=0.001, IL-6 (P=0.012, and IL-27 (only detectable in APAC eyes. Age was positively correlated with IL-12 (P=0.022 and IL-6 (P=0.037, and time elapsed between APAC onset and aqueous humor samples collection was positively correlated with IL-15 (P=0.037, IL-27 (P=0.040, and TNF-α (P=0.042. CONCLUSION: Several proinflammatory cytokines including IL-12,IL-15, IL-6 and IL-27, were elevated in the APAC eyes and may be implicated in its pathologic mechanism.

  15. Twenty years' delay of fellow eye involvement in herpes simplex virus type 2-associated bilateral acute retinal necrosis syndrome

    NARCIS (Netherlands)

    Schlingemann, R. O.; Bruinenberg, M.; Wertheim-van Dillen, P.; Feron, E.

    1996-01-01

    PURPOSE: To describe a case of acute retinal necrosis with concurrent encephalitis and determine the causative virus. The patient had a history of presumed acute retinal necrosis in the left eye at the age of 8 years and recurrent genital herpes. METHODS: Diagnostic anterior chamber puncture of the

  16. Two- and three-dimensional topographic analysis of pathologically myopic eyes with dome-shaped macula and inferior staphyloma by spectral domain optical coherence tomography.

    Science.gov (United States)

    García-Ben, Antonio; Kamal-Salah, Radua; García-Basterra, Ignacio; Gonzalez Gómez, Ana; Morillo Sanchez, María José; García-Campos, Jose Manuel

    2017-05-01

    To investigate the posterior anatomical structure of pathologically myopic eyes with dome-shaped macula and inferior staphyloma using spectral domain optical coherence tomography (SD-OCT). Our database of 260 pathologically myopic eyes was analyzed retrospectively to identify patients with dome-shaped macula and inferior staphyloma. All patients underwent vertical and horizontal SD-OCT scans across the central fovea, with three-dimensional macular map reconstruction. Best-corrected visual acuity, axial length, and choroidal thickness measurements were recorded. The macular bulge height was also analyzed in eyes with dome-shaped macula. In the three-dimensional images, the symmetry and orientation of the main plane of the inward incurvation of the macula were examined. Twenty-eight (10.7%) of the 260 pathologically myopic eyes had dome-shaped macula of one of three different types: a round radially symmetrical dome (eight eyes, 28.5%), a horizontal axially symmetrical oval-shaped dome (15 eyes, 53.5%), or a vertical axially symmetrical oval-shaped dome (five eyes, 17.8%). The macular bulge height was significantly greater in horizontal oval-shaped dome eyes (p = 0.01, for each comparison). Inferior posterior staphylomas were observed in ten (3.8%) of the 260 pathologically myopic eyes with asymmetrical macular bends. Vertical and horizontal OCT sectional scanning in combination with three-dimensional macular map reconstruction provides important information for understanding the posterior anatomical structure of dome-shaped macula and inferior staphyloma in pathologically myopic eyes.

  17. Statistical characteristics of aberrations of human eyes after small incision lenticule extraction surgery and analysis of visual performance with individual eye model.

    Science.gov (United States)

    Lou, Qiqi; Wang, Yan; Wang, Zhaoqi; Liu, Yongji; Zhang, Lin; Fang, Hui

    2015-09-01

    Preoperative and postoperative wavefront aberrations of 73 myopic eyes with small incision lenticule extraction surgery are analyzed in this paper. Twenty-eight postoperative individual eye models are constructed to investigate the visual acuity (VA) of human eyes. Results show that in photopic condition, residual defocus, residual astigmatism, and higher-order aberrations are relatively small. 100% of eyes reach a VA of 0.8 or better, and 89.3% of eyes reach a VA of 1.0 or better. In scotopic condition, the residual defocus and the higher-order aberrations are, respectively, 1.9 and 8.5 times the amount of that in photopic condition, and the defocus becomes the main factor attenuating visual performance.

  18. Relationship between abstract thinking and eye gaze pattern in patients with schizophrenia

    Science.gov (United States)

    2014-01-01

    Background Effective integration of visual information is necessary to utilize abstract thinking, but patients with schizophrenia have slow eye movement and usually explore limited visual information. This study examines the relationship between abstract thinking ability and the pattern of eye gaze in patients with schizophrenia using a novel theme identification task. Methods Twenty patients with schizophrenia and 22 healthy controls completed the theme identification task, in which subjects selected which word, out of a set of provided words, best described the theme of a picture. Eye gaze while performing the task was recorded by the eye tracker. Results Patients exhibited a significantly lower correct rate for theme identification and lesser fixation and saccade counts than controls. The correct rate was significantly correlated with the fixation count in patients, but not in controls. Conclusions Patients with schizophrenia showed impaired abstract thinking and decreased quality of gaze, which were positively associated with each other. Theme identification and eye gaze appear to be useful as tools for the objective measurement of abstract thinking in patients with schizophrenia. PMID:24739356

  19. Registration of eye reflection and scene images using an aspherical eye model.

    Science.gov (United States)

    Nakazawa, Atsushi; Nitschke, Christian; Nishida, Toyoaki

    2016-11-01

    This paper introduces an image registration algorithm between an eye reflection and a scene image. Although there are currently a large number of image registration algorithms, this task remains difficult due to nonlinear distortions at the eye surface and large amounts of noise, such as iris texture, eyelids, eyelashes, and their shadows. To overcome this issue, we developed an image registration method combining an aspherical eye model that simulates nonlinear distortions considering eye geometry and a two-step iterative registration strategy that obtains dense correspondence of the feature points to achieve accurate image registrations for the entire image region. We obtained a database of eye reflection and scene images featuring four subjects in indoor and outdoor scenes and compared the registration performance with different asphericity conditions. Results showed that the proposed approach can perform accurate registration with an average accuracy of 1.05 deg by using the aspherical cornea model. This work is relevant for eye image analysis in general, enabling novel applications and scenarios.

  20. Change in convergence and accommodation after two weeks of eye exercises in typical young adults

    OpenAIRE

    Horwood, Anna M.; Toor, Sonia S.; Riddell, Patricia M.

    2014-01-01

    Abstract: Introduction\\ud Although eye exercises appear to help heterophoria, convergence insufficiency and intermittent strabismus, true treatment effects can be confounded by placebo, practice and encouragement factors. This study assessed objective changes in vergence and accommodation responses in typical naïve young adults after two weeks of exercises compared to control conditions to assess the extent of treatment effects occur above other factors.\\ud Methods\\ud 156 asymptomatic young a...

  1. Eye-based head gestures

    DEFF Research Database (Denmark)

    Mardanbegi, Diako; Witzner Hansen, Dan; Pederson, Thomas

    2012-01-01

    A novel method for video-based head gesture recognition using eye information by an eye tracker has been proposed. The method uses a combination of gaze and eye movement to infer head gestures. Compared to other gesture-based methods a major advantage of the method is that the user keeps the gaze...... mobile phone screens. The user study shows that the method detects a set of defined gestures reliably.......A novel method for video-based head gesture recognition using eye information by an eye tracker has been proposed. The method uses a combination of gaze and eye movement to infer head gestures. Compared to other gesture-based methods a major advantage of the method is that the user keeps the gaze...

  2. Comparison of hyaluronic acid-containing topical eye drops with carbomer-based topical ocular gel as a tear replacement in canine keratoconjunctivitis sicca: A prospective study in twenty five dogs

    Directory of Open Access Journals (Sweden)

    David Williams

    2012-12-01

    Full Text Available The aim of this study was to evaluate the efficacy of a hyaluronic acid containing eye drop in ameliorating ocular surface pathology and discomfort in canine keratoconjunctivitis sicca (KCS. Twenty five dogs with KCS treated with a topical carbomer (CA-based tear replacement gel were moved to treatment with a hyaluronic acid (HA-containing tear replacement eye drop. Dogs were subject to a full ophthalmic examination at the beginning of the study and after two and four weeks of treatment, Schirmer tear tests (STTs were performed at each examination. Conjunctival hyperemia, ocular discharge and ocular irritation were evaluated and scored on a 0-3 semi-quantitative scale. Values were compared before and after 4 weeks of treatment using a paired t-test. Evaluation scores were compared using the Wilcoxon signed rank test. The transfer from CA-based to HA-containing tear replacement significantly decreased the conjunctival hyperemia score from 2.12 ± 0.73 to 1.26 ± 0.59 and ocular discomfort was lowered from 2.11 ± 0.97 to 0.93 ± 0.75. Ocular discharge was reduced from a score of 1.04 ± 0.82 to 0.70 ± 0.53, however, the decrease did not reach statistical significance. Schirmer tear test was increased with statistical significance (p < 0.001 but given that the increase was only from 5.42 ± 3.50 to 6.19 ± 3.86 mm min-1; this was not considered clinically significant. This study demonstrated that HA-containing eye drops used twice daily in dogs with KCS had greater ameliorative effects on ocular surface health and discomfort than did CA-based topical gels used as or more frequently.

  3. Paralysis of the orbicularis muscle of the eye using botulinum toxin type A in the treatment for dry eye.

    Science.gov (United States)

    Serna-Ojeda, Juan Carlos; Nava-Castaneda, Angel

    2017-03-01

    To evaluate the efficacy of botulinum toxin type A injection to cause orbicularis eyelid muscle paralysis to improve dry eye signs and symptoms. A prospective, randomized, comparative eye-to-eye and interventional study was performed. Patients with dry eye symptoms and positive fluorescein corneal staining were included. Randomly one eyelid received a subcutaneous injection of botulinum toxin in the medial orbicularis muscle portion of the lower eyelid, and the other eye received placebo. The subjective evaluation was achieved with a questionnaire assessing symptoms, quality of vision and ocular comfort level. The objective evaluation included the measurement of the tear film break-up time (TBUT), Schirmer's test and corneal and conjunctival staining. Twenty patients were included with a mean age of 59.5 years. Two weeks after the botulinum toxin injection, all patients showed a decrease in the horizontal movement of the lower eyelid when blinking. The eyes in the active treatment group showed better scores compared with the sham group in four symptoms 4 weeks after the treatment. The TBUT was higher at 1 and 3 months in the active treatment group. The corneal and conjunctival staining were significantly lower in the active treatment group at 1 and 3 months, and the Schirmer's test showed better measurements in the same group at 2 weeks, 1 month and 3 months. There were no adverse events reported. The injection of botulinum toxin A in the medial part of the lower eyelid is an effective and safe procedure that temporally improves some of the signs and symptoms of patients with dry eye. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  4. Recognition method of construction conflict based on driver's eye movement.

    Science.gov (United States)

    Xu, Yi; Li, Shiwu; Gao, Song; Tan, Derong; Guo, Dong; Wang, Yuqiong

    2018-04-01

    Drivers eye movement data in simulated construction conflicts at different speeds were collected and analyzed to find the relationship between the drivers' eye movement and the construction conflict. On the basis of the relationship between the drivers' eye movement and the construction conflict, the peak point of wavelet processed pupil diameter, the first point on the left side of the peak point and the first blink point after the peak point are selected as key points for locating construction conflict periods. On the basis of the key points and the GSA, a construction conflict recognition method so called the CCFRM is proposed. And the construction conflict recognition speed and location accuracy of the CCFRM are verified. The good performance of the CCFRM verified the feasibility of proposed key points in construction conflict recognition. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Two eyes, one vision: binocular motion perception in human visual cortex

    NARCIS (Netherlands)

    Barendregt, M.

    2016-01-01

    An important aspect of human vision is the fact that it is binocular, i.e. that we have two eyes. As a result, the brain nearly always receives two slightly different images of the same visual scene. Yet, we only perceive a single image and thus our brain has to actively combine the binocular visual

  6. Update on excimer laser photorefractive keratectomy (PRK) at Cedars-Sinai Medical Center: two-year experience

    Science.gov (United States)

    Maguen, Ezra I.; Salz, James J.; Warren, Cathy; Papaioannou, Thanassis; Nesburn, Anthony B.; Macy, Jonathan I.; Hofbauer, John; Grundfest, Warren S.

    1993-06-01

    Our two year experience with excimer laser photorefractive keratectomy for the correction of myopia on 160 eyes of 128 patients is described. All eyes were treated with a VISX Twenty- Twenty excimer laser, with the following parameters: radiant exposure 160 mJ/cm2, frequency 5 Hz, ablation zone diameter 5.0 to 5.5 mm, and stromal ablation rate 0.18 to 0.33 (mu) /pulse. A suction fixation ring was used in all cases either with nitrogen flow (79 eyes) or without nitrogen flow (81 eyes) across the cornea. Follow-up ranged from one month (152 eyes) to 24 months (12 eyes). The results are stable between 3 and 24 months with less than 0.25 D change in the mean postoperative spherical equivalents. In eyes with a follow-up of 6 to 24 months, 77% to 100% were 20/40 or better uncorrected, and 84% to 92% were corrected to within +/- 1 D of emmetropia. Further follow-up is needed to assess the long term safety and efficacy of the procedure.

  7. Using an eye tracker for accurate eye movement artifact correction

    NARCIS (Netherlands)

    Kierkels, J.J.M.; Riani, J.; Bergmans, J.W.M.; Boxtel, van G.J.M.

    2007-01-01

    We present a new method to correct eye movement artifacts in electroencephalogram (EEG) data. By using an eye tracker, whose data cannot be corrupted by any electrophysiological signals, an accurate method for correction is developed. The eye-tracker data is used in a Kalman filter to estimate which

  8. Efficacy of atropine and anisodamine eye drops for adolescent pseudomyopia

    OpenAIRE

    Hui-Jie Wang

    2017-01-01

    AIM:To investigate the effect and local influence of atropine and anisodamine eye drops on adolescent pseudomyopia. METHODS:Totally 110 cases of juvenile pseudomyopia were randomly divided into two groups, the control group was given 10g/L atropine sulfate eye gel, and the observation group was treated with 5g/L raceanisodamine eye drops. The efficacy of two methods, the changes of axial length and intraocular pressure before and after treatment, and the incidence of adverse reactions were co...

  9. Rhegmatogenous retinal detachments associated to Stickler syndrome in a tertiary eye care center in Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Alshahrani ST

    2015-12-01

    Full Text Available Saeed T Alshahrani,1 Nicola G Ghazi,2 Saba Al-Rashaed2 1Ophthalmology Department, King Fahad Specialist Hospital, Dammam, 2Vitreoretinal Department, King Khaled Eye Specialist Hospital, Riyadh, Kingdom of Saudi Arabia Purpose: To investigate the clinical findings and outcomes of rhegmatogenous retinal detachment (RRD in Stickler syndrome on affected and fellow eyes that underwent prophylactic retinopexy.Patients and methods: Chart review of 70 eyes (62 patients. Incidence of RRD, postoperative visual acuity, and risk factors were evaluated.Results: Twenty-two patients (35% had RRD in the fellow eye, 37% of the eyes had cataract, 93% had macular detachment, 50% had proliferative vitreoretinopathy, and 41% had posterior vitreous detachment. Success rates were: 60% of patients after scleral buckling; 57.1% after pars plana vitrectomy; and 75% after combined scleral buckling and pars plana vitrectomy. Sixty-one (93.8% of patients had successful surgery (including second surgery. Silicone oil tamponade was significantly associated with final anatomic outcome, with a protective odds ratio of 0.11 (P=0.027. Visual acuity improved in 54% of eyes and decreased in 5%. Statistically significant associations were present for eyes with final visual acuity ≥20/200, and total retinal detachment (P<0.001; preoperative cataract (P=0.023; and proliferative vitreoretinopathy (P<0.001. RRD developed in 16/44 eyes despite laser prophylaxis.Conclusion: Prophylactic retinopexy was not beneficial for Stickler syndrome patients. Success of primary surgery for RRD remains low. The primary surgery should be vitrectomy combined with scleral buckling and silicone oil tamponade. Keywords: Stickler syndrome, retinopexy, Gulf States, Saudi Arabia, ocular genetics, arthro-ophthalmopathy, collagen disorder

  10. Design, Sensing and Control of a Robotic Prosthetic Eye for Natural Eye Movement

    Directory of Open Access Journals (Sweden)

    J. J. Gu

    2006-01-01

    Full Text Available Loss of an eye is a tragedy for a person, who may suffer psychologically and physically. This paper is concerned with the design, sensing and control of a robotic prosthetic eye that moves horizontally in synchronization with the movement of the natural eye. Two generations of robotic prosthetic eye models have been developed. The first generation model uses an external infrared sensor array mounted on the frame of a pair of eyeglasses to detect the natural eye movement and to feed the control system to drive the artificial eye to move with the natural eye. The second generation model removes the impractical usage of the eye glass frame and uses the human brain EOG (electro-ocular-graph signal picked up by electrodes placed on the sides of a person's temple to carry out the same eye movement detection and control tasks as mentioned above. Theoretical issues on sensor failure detection and recovery, and signal processing techniques used in sensor data fusion, are studied using statistical methods and artificial neural network based techniques. In addition, practical control system design and implementation using micro-controllers are studied and implemented to carry out the natural eye movement detection and artificial robotic eye control tasks. Simulation and experimental studies are performed, and the results are included to demonstrate the effectiveness of the research project reported in this paper.

  11. Watching Eyes and Living up to Expectations: Unkind, Not Kind, Eyes Increase First Mover Cooperation in a Sequential Prisoner’s Dilemma

    Directory of Open Access Journals (Sweden)

    Loren Pauwels

    2017-04-01

    Full Text Available (1 Background: Why and when images of watching eyes encourage prosocial behavior is still subject to discussion, and two recent meta-analyses show no effect of watching eyes on generosity. This study aims to discern the effect of watching eyes of different valence on two separate aspects of prosocial behavior, and additionally investigates whether individuals’ social value orientation moderates the effect of eyes. (2 Methods: Individuals take on the role of either a first or second mover in an incentivized, anonymous sequential prisoner’s dilemma (n = 247, a two-person game which separates the need to form expectations about the other player (first mover cooperation, trust from the motive of greed (second mover cooperation, reciprocity. During decision-making, a picture of either kind eyes, unkind eyes, or a control picture is presented above each decision matrix. (3 Results: The results indicate that unkind eyes, and not kind eyes, significantly boost first mover cooperation. In contrast, neither type of eye cues increase second mover cooperation. Social value orientation does not moderate these effects. (4 Conclusions: Thus, the data suggest that the valence of eye cues matters, and we propose that unkind eyes urge first movers to live up to the interaction partner’s expectations.

  12. Impact of Air Movement on Eye Symptoms

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Sakoi, Tomonori; Kolencíková, Sona

    2013-01-01

    The impact of direction, oscillation and temperature of isothermal room air movement on eye discomfort and tear film quality was studied. Twenty-four male subjects participated in the experiment. Horizontal air movement against the face and chest was generated by a large desk fan – LDF and a small...... when the airflow was directed against the face and when against the chest, LDF with and without oscillation and PV. Eye tear film samples were taken and analyzed at the beginning and the end of the exposures. Eye irritation and dryness were reported by the subjects. The air movement under individual...... control did not change significantly the tear film quality though tendency for improvement was observed. Eye dryness increased much when the airflow was blowing constantly against the face compared to oscillating airflow, airflow directed against the chest and upward airflow against the face....

  13. Wide-field schematic eye models with gradient-index lens.

    Science.gov (United States)

    Goncharov, Alexander V; Dainty, Chris

    2007-08-01

    We propose a wide-field schematic eye model, which provides a more realistic description of the optical system of the eye in relation to its anatomical structure. The wide-field model incorporates a gradient-index (GRIN) lens, which enables it to fulfill properties of two well-known schematic eye models, namely, Navarro's model for off-axis aberrations and Thibos's chromatic on-axis model (the Indiana eye). These two models are based on extensive experimental data, which makes the derived wide-field eye model also consistent with that data. A mathematical method to construct a GRIN lens with its iso-indicial contours following the optical surfaces of given asphericity is presented. The efficiency of the method is demonstrated with three variants related to different age groups. The role of the GRIN structure in relation to the lens paradox is analyzed. The wide-field model with a GRIN lens can be used as a starting design for the eye inverse problem, i.e., reconstructing the optical structure of the eye from off-axis wavefront measurements. Anatomically more accurate age-dependent optical models of the eye could ultimately help an optical designer to improve wide-field retinal imaging.

  14. Eye Tracker Accuracy: Quantitative Evaluation of the Invisible Eye Center Location

    OpenAIRE

    Wyder, Stephan; Cattin, Philippe C.

    2017-01-01

    Purpose. We present a new method to evaluate the accuracy of an eye tracker based eye localization system. Measuring the accuracy of an eye tracker's primary intention, the estimated point of gaze, is usually done with volunteers and a set of fixation points used as ground truth. However, verifying the accuracy of the location estimate of a volunteer's eye center in 3D space is not easily possible. This is because the eye center is an intangible point hidden by the iris. Methods. We evaluate ...

  15. A portable device for measuring donor corneal transparency in eye banks.

    Science.gov (United States)

    Parekh, Mohit; Ferrari, Stefano; Ruzza, Alessandro; Pugliese, Mariarosaria; Ponzin, Diego; Salvalaio, Gianni

    2014-03-01

    To develop a portable device for measuring the donor corneal transparency and validate its efficacy for corneal evaluation in the eye-banks and for research. The transparency device (TD) has a light source, a detachable system for corneal insertion and a base for light transmission. The probe detects the transmitted light which is measured by a lux-meter. A contact lens was set as 'control' to reduce the light scattering concern, an empty petri-plate as 'blank' and the cornea as 'sample'. Two experts and non-experts (masked) observed the corneas for subjective analysis which was then compared using the TD. The parameters observed were scars, foreign-body, stromal-deformities, folds, thickness and opacity which were then converted to a relative overall percentage by the observer. Twenty corneas were evaluated for correlation, five tissues to obtain standard-deviation and twenty-four pairs for a comparative study. Experts mimicked the eye-banks with long-term experience while non-experts mimicked the emerging eye-banks. Subjective values by the experts closely resembled the measurements by TD. The average correlation between the experts and the non-experts to TD was 0.985 and 0.960 respectively. TD showed higher reproducibility than experts followed by the non-experts. The comparative study showed that increase in thickness reduces the transparency. TD is portable, easy, efficient, maintains sterility and less expensive hence the emerging eye-banks and researchers can use to raise their standards and evaluate the transparency for in vitro tests and comparative studies. The suitable transparency for the cornea deemed for clinical applications was found to be >75 %.

  16. Applying the decision moving window to risky choice: Comparison of eye-tracking and mousetracing methods

    Directory of Open Access Journals (Sweden)

    Ana M. Franco-Watkins

    2011-12-01

    Full Text Available Currently, a disparity exists between the process-level models decision researchers use to describe and predict decision behavior and the methods implemented and metrics collected to test these models. The current work seeks to remedy this disparity by combining the advantages of work in decision research (mouse-tracing paradigms with contingent information display and cognitive psychology (eye-tracking paradigms from reading and scene perception. In particular, we introduce a new decision moving-window paradigm that presents stimulus information contingent on eye fixations. We provide data from the first application of this method to risky decision making, and show how it compares to basic eye-tracking and mouse-tracing methods. We also enumerate the practical, theoretical, and analytic advantages this method offers above and beyond both mouse-tracing with occlusion and basic eye tracking of information without occlusion. We include the use of new metrics that offer more precision than those typically calculated on mouse-tracing data as well as those not possible or feasible within the mouse-tracing paradigm.

  17. Eye Movement Disorders

    Science.gov (United States)

    ... work properly. There are many kinds of eye movement disorders. Two common ones are Strabismus - a disorder ... in "crossed eyes" or "walleye." Nystagmus - fast, uncontrollable movements of the eyes, sometimes called "dancing eyes" Some ...

  18. Gastrointestinal tract volume measurement method using a compound eye type endoscope

    Science.gov (United States)

    Yoshimoto, Kayo; Yamada, Kenji; Watabe, Kenji; Kido, Michiko; Nagakura, Toshiaki; Takahashi, Hideya; Nishida, Tsutomu; Iijima, Hideki; Tsujii, Masahiko; Takehara, Tetsuo; Ohno, Yuko

    2015-03-01

    We propose an intestine volume measurement method using a compound eye type endoscope. This method aims at assessment of the gastrointestinal function. Gastrointestinal diseases are mainly based on morphological abnormalities. However, gastrointestinal symptoms are sometimes apparent without visible abnormalities. Such diseases are called functional gastrointestinal disorder, for example, functional dyspepsia, and irritable bowel syndrome. One of the major factors for these diseases is abnormal gastrointestinal motility. For the diagnosis of the gastrointestinal tract, both aspects of organic and functional assessment is important. While endoscopic diagnosis is essential for assessment of organic abnormalities, three-dimensional information is required for assessment of the functional abnormalities. Thus, we proposed the three dimensional endoscope system using compound eye. In this study, we forces on the volume of gastrointestinal tract. The volume of the gastrointestinal tract is thought to related its function. In our system, we use a compound eye type endoscope system to obtain three-dimensional information of the tract. The volume can be calculated by integrating the slice data of the intestine tract shape using the obtained three-dimensional information. First, we evaluate the proposed method by known-shape tube. Then, we confirm that the proposed method can measure the tract volume using the tract simulated model. Our system can assess the wall of gastrointestinal tract directly in a three-dimensional manner. Our system can be used for examination of gastric morphological and functional abnormalities.

  19. Demonstration of angle widening using EyeCam after laser peripheral iridotomy in eyes with angle closure.

    Science.gov (United States)

    Perera, Shamira A; Quek, Desmond T; Baskaran, Mani; Tun, Tin A; Kumar, Rajesh S; Friedman, David S; Aung, Tin

    2010-06-01

    To evaluate EyeCam in detecting changes in angle configuration after laser peripheral iridotomy (LPI) in comparison to gonioscopy, the reference standard. Prospective comparative study. Twenty-four subjects (24 eyes) with primary angle-closure glaucoma (PACG) were recruited. Gonioscopy and EyeCam (Clarity Medical Systems) imaging of all 4 angle quadrants were performed, before and 2 weeks after LPI. Images were graded according to angle structures visible by an observer masked to clinical data or the status of LPI, and were performed in a random order. Angle closure in a quadrant was defined as the inability to visualize the posterior trabecular meshwork. We determined the number of quadrants with closed angles and the mean number of clock hours of angle closure before and after LPI in comparison to gonioscopy. Using EyeCam, all 24 eyes showed at least 1 quadrant of angle widening after LPI. The mean number of clock hours of angle closure decreased significantly, from 8.15 +/- 3.47 clock hours before LPI to 1.75 +/- 2.27 clock hours after LPI (P gonioscopy showed 1.0 +/- 1.41 (95% CI, 0.43-1.57) quadrants opening from closed to open after LPI compared to 2.0 +/- 1.28 (95% CI, 1.49-2.51, P = .009) quadrants with EyeCam. Intra-observer reproducibility of grading the extent of angle closure in clock hours in EyeCam images was moderate to good (intraclass correlation coefficient 0.831). EyeCam may be used to document changes in angle configuration after LPI in eyes with PACG. Copyright 2010 Elsevier Inc. All rights reserved.

  20. Investigating emotion recognition and empathy deficits in Conduct Disorder using behavioural and eye-tracking methods

    OpenAIRE

    Martin-Key, Nayra, Anna

    2017-01-01

    The aim of this thesis was to characterise the nature of the emotion recognition and empathy deficits observed in male and female adolescents with Conduct Disorder (CD) and varying levels of callous-unemotional (CU) traits. The first two experiments employed behavioural tasks with concurrent eye-tracking methods to explore the mechanisms underlying facial and body expression recognition deficits. Having CD and being male independently predicted poorer facial expression recognition across all ...

  1. An Expert System for Diagnosing Eye Diseases using Forward Chaining Method

    Science.gov (United States)

    Munaiseche, C. P. C.; Kaparang, D. R.; Rompas, P. T. D.

    2018-02-01

    Expert System is a system that seeks to adopt human knowledge to the computer, so that the computer can solve problems which are usually done by experts. The purpose of medical expert system is to support the diagnosis process of physicians. It considers facts and symptoms to provide diagnosis. This implies that a medical expert system uses knowledge about diseases and facts about the patients to suggest diagnosis. The aim of this research is to design an expert system application for diagnosing eye diseases using forward chaining method and to figure out user acceptance to this application through usability testing. Eye is selected because it is one of the five senses which is very sensitive and important. The scope of the work is extended to 16 types of eye diseases with 41 symptoms of the disease, arranged in 16 rules. The computer programming language employed was the PHP programming language and MySQL as the Relational Database Management System (RDBMS). The results obtained showed that the expert system was able to successfully diagnose eye diseases corresponding to the selected symptoms entered as query and the system evaluation through usability testing showed the expert system for diagnosis eye diseases had very good rate of usability, which includes learnability, efficiency, memorability, errors, and satisfaction so that the system can be received in the operational environment.

  2. Clinical effect of 1g/L anthocyanin eye-patch for mild and moderate dry eye

    Directory of Open Access Journals (Sweden)

    Ke-Hua Wang

    2018-05-01

    Full Text Available AIM:To evaluate the clinic efficacy of 1g/L anthocyanin eye-patch for mild and moderate dry eye. METHODS: In this prospective and multicenter study, a total of 320 cases(640 eyeswith mild and moderate dry eye were enrolled from 8 Aier Eye Hospitals in Changsha, Chongqing, Wuhan and so on from October 2016 to April 2017. The patients were assigned to eye patch group(160 casesand artificial tears group(160 casesbased on random number table. The patients in eye-patch group used 1g/L of anthocyanin eye-patch for more than 6h during night sleep, while the patients in artificial tears group used polyvinyl alcohol eye drops for 4 times per day. The evaluation of symptoms and signs were conducted on 1d before the treatment and 14d after the treatment. The evaluation of symptoms adopted the Ocular Surface Disease Index(OSDI, while the observation of signs included tear secretion test(Schirmer Ⅰ test, SⅠt, first noninvasive tear breakup time(NITBUTfas well as average noninvasive tear breakup time(NITBUTavmeasured by Oculus ocular surface analyser. RESULTS: OSDI score, NITBUTf and NITBUTav in the two groups after treatment were significantly improved compared with that before treatment, and the difference had a statistical significance(PP>0.05. There was no significant difference in OSDI score, NITBUTf, NITBUTav and SⅠt between the two groups after treatment(P>0.05.CONCLUSION: The 1g/L anthocyanin eye-patch has similar efficacy with artificial tears for mild and moderate dry eye, which can effectively improve the symptoms and tear film stability.

  3. Comparison of novel lipid-based eye drops with aqueous eye drops for dry eye: a multicenter, randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Simmons PA

    2015-04-01

    Full Text Available Peter A Simmons, Cindy Carlisle-Wilcox, Joseph G Vehige Ophthalmology Research and Development, Allergan, Inc., Irvine, CA, USA Background: Dry eye may be caused or exacerbated by deficient lipid secretion. Recently, lipid-containing artificial tears have been developed to alleviate this deficiency. Our study compared the efficacy, safety, and acceptability of lipid-containing eye drops with that of aqueous eye drops.Methods: A non-inferiority, randomized, parallel-group, investigator-masked multicenter trial was conducted. Subjects with signs and symptoms of dry eye were randomized to use one of two lipid-containing artificial tears, or one of two aqueous artificial tears. Subjects instilled assigned drops in each eye at least twice daily for 30 days. The primary efficacy analysis tested non-inferiority of a preservative-free lipid tear formulation (LT UD to a preservative-free aqueous tear formulation (AqT UD for change in Ocular Surface Disease Index (OSDI score from baseline at day 30. Secondary measures included OSDI at day 7, tear break-up time (TBUT, corneal and conjunctival staining, Schirmer’s test, acceptability and usage questionnaires, and safety assessments.Results: A total of 315 subjects were randomized and included in the analyses. Subjects reported instilling a median of three doses of study eye drops per day in all groups. At days 7 and 30, all groups showed statistically significant improvements from baseline in OSDI (P<0.001 and TBUT (P≤0.005. LT UD was non-inferior to AqT UD for mean change from baseline in OSDI score at day 30. No consistent or clinically relevant differences for the other efficacy variables were observed. Acceptability was generally similar across the groups and there was a low incidence of adverse events.Conclusion: In this heterogeneous population of dry eye subjects, there were no clinically significant differences in safety, effectiveness, and acceptability between lipid-containing artificial tears

  4. Real-Time Control of a Video Game Using Eye Movements and Two Temporal EEG Sensors.

    Science.gov (United States)

    Belkacem, Abdelkader Nasreddine; Saetia, Supat; Zintus-art, Kalanyu; Shin, Duk; Kambara, Hiroyuki; Yoshimura, Natsue; Berrached, Nasreddine; Koike, Yasuharu

    2015-01-01

    EEG-controlled gaming applications range widely from strictly medical to completely nonmedical applications. Games can provide not only entertainment but also strong motivation for practicing, thereby achieving better control with rehabilitation system. In this paper we present real-time control of video game with eye movements for asynchronous and noninvasive communication system using two temporal EEG sensors. We used wavelets to detect the instance of eye movement and time-series characteristics to distinguish between six classes of eye movement. A control interface was developed to test the proposed algorithm in real-time experiments with opened and closed eyes. Using visual feedback, a mean classification accuracy of 77.3% was obtained for control with six commands. And a mean classification accuracy of 80.2% was obtained using auditory feedback for control with five commands. The algorithm was then applied for controlling direction and speed of character movement in two-dimensional video game. Results showed that the proposed algorithm had an efficient response speed and timing with a bit rate of 30 bits/min, demonstrating its efficacy and robustness in real-time control.

  5. Clinical study of 3g/L sodium hyaluronate eye drops with bromhexine hydrochloride tablets for dry eye

    Directory of Open Access Journals (Sweden)

    Hui-Qun Xu

    2018-04-01

    Full Text Available AIM:To investigate the clinical efficacy of 3g/L sodium hyaluronate eye drops combined with bromhexine hydrochloride tablets on the treatment of dry eye. METHODS:Totally 200 patients with dry eye were randomly divided into the control group(n=100and observation group(n=100. Patients in two groups were given 3g/L sodium hyaluronate eye drops and physiotherapy. On the basis of this, the observation group were treated with bromhexine hydrochloride tablets. The inflammatory factors(IL-6, IL-10, TNF-α and IL-1βlevels and ocular symptom scores(OSDI, BUT, SⅠt, FLin the two groups were compared between before and after treatment. And the clinical efficacy and adverse reactions were evaluated. RESULTS: After treatment, the IL-6, IL-10, TNF-α, IL-1β, OSDI and FL scores in two groups were significantly lower than those before treatment, and BUT and SⅠt were significantly higher than those before treatment. Moreover, the improvement degree of the above indexes in the observation group were better than those in the control group, showing statistically significant difference(Pχ2=5.531, P=0.019, but there was no significant difference in the incidence of adverse reactions between the two groups(χ2=0.307, P=0.579. CONCLUSION:As for the patients with dry eye, the combination of 3g/L sodium hyaluronate eye drops with bromhexine hydrochloride tablets can significantly decrease the level of inflammatory factors, improve the eye symptoms and the clinical total efficiency, without increasing treatment-related adverse effects.

  6. Eye Irritation Test of Bovis Calculus Pharmacopuncture Solutions for Eye Drop

    Directory of Open Access Journals (Sweden)

    Hyeong-sik Seo

    2008-06-01

    Full Text Available Objective : This study was done to investigate the safety of Bovis Calculus pharmacopuncture solution manufactured with freezing dryness method to use eye drop. Methods : The eye irritation test of this material was performed according to the Regulation of Korea Food & Drug Administration (2005. 10. 21, KFDA 2005-60. After Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, the auther observed eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Results : 1. After Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, there wasn’t physical problem at 9 rabbits. 2. After Bovis Calculus pharmacopuncture solutionwas medicated in the left eye of the rabbits, there wasn’t eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Conclusions : I suggested that Bovis Calculus pharmacopuncture solution didn’t induced eye irritation in rabbits.

  7. Intra-arterial chemotherapy for retinoblastoma: Two-year results from tertiary eye-care center in India

    Directory of Open Access Journals (Sweden)

    Pukhraj Rishi

    2017-01-01

    Full Text Available Aim: The aim of this study is to describe treatment outcomes and complications of selective intra-arterial chemotherapy (IAC for intraocular retinoblastoma (RB. Materials and Methods: A retrospective, interventional series of 10 eyes with RB which underwent IAC using melphalan (5 mg/7.5 mg and topotecan (1 mg, or melphalan (5 mg/7.5 mg alone. Treatment outcomes were evaluated in terms of tumor control, vitreous seeds (VS and subretinal seeds (SRS control, and globe salvage rates. Results: Ten eyes of 10 patients underwent 38 IAC sessions (mean = 3.8; median = 4; range = 3–5 sessions. Following IAC, complete regression of main tumor was seen in 9 eyes (90% and partial regression in 1 (10%. All four eyes with SRS showed complete regression (100%. Of 5 eyes with VS, 3 eyes (60% showed complete regression, 1 eye (20% showed relapse, while 1 eye (20% showed no response. Globe salvage was achieved in 8 of 10 eyes (80%. Complications included transient ophthalmic artery narrowing (n = 2, branched retinal vein occlusion (n = 1, forehead skin pigmentation (n = 1, and vitreous hemorrhage (n = 2. There was no case of stroke, hemiplegia, metastasis, or death. Transient hematological changes included relative pancytopenia (n = 4, relative leukopenia (n = 5, and relative thrombocytopenia (n = 4. Mean follow-up was 26 months (median = 28, range = 13–36 from the initiation of first IAC. Conclusions: IAC is an effective therapy for globe preservation in eyes with intraocular RB, in the setting of a developing country like India. Larger studies with longer follow-up are required to validate these results.

  8. EYE GAZE TRACKING

    DEFF Research Database (Denmark)

    2017-01-01

    This invention relates to a method of performing eye gaze tracking of at least one eye of a user, by determining the position of the center of the eye, said method comprising the steps of: detecting the position of at least three reflections on said eye, transforming said positions to spanning...... a normalized coordinate system spanning a frame of reference, wherein said transformation is performed based on a bilinear transformation or a non linear transformation e.g. a möbius transformation or a homographic transformation, detecting the position of said center of the eye relative to the position...... of said reflections and transforming this position to said normalized coordinate system, tracking the eye gaze by tracking the movement of said eye in said normalized coordinate system. Thereby calibration of a camera, such as knowledge of the exact position and zoom level of the camera, is avoided...

  9. Design of a new two element OSLD Badge for eye lens monitoring

    International Nuclear Information System (INIS)

    Kulkarni, M.S.; Munish Kumar; Ratna, P.; Babu, D.A.R.; Muthe, K.P.; Biju, K.; Sunil, C.; Sharma, D.N.

    2014-01-01

    Normally the dose to the vicinity of the eye is received by the occupational radiation workers who handle radioisotopes or doctors who perform interventional radiographic procedures. The Eye dosimeters provide an estimate of the radiation dose to the lens of the eye. In the recent ICRP-2011 recommendations, the equivalent dose limit for the lens of the eye has been reduced from 150 mSv in a year to 20 mSv in a year for all the occupational workers. To ensure that the dose limit for the eye lens does not exceed the prescribed dose limits, various eye lens dosimeters have been designed and are being used internationally. All these eye dosimeters consist of one natural LiF based thermoluminescence dosimeter (TLD) element sealed in a plastic holder. The design of the eye dosimeter and place of wear (near the eye) plays an important role in correct estimation of the dose to the lens of the eye. It is generally seen that the eye dosimeter when worn with the head strap on the forehead near the eye, the dose the element receives can be easily correlated to the eye dose. This paper presents the design of a new Eye lens dosimeter based on optically stimulated luminescence (OSL) detectors for its possible use by the occupational workers covering the medical, industrial and nuclear facilities for assessing the Hp(3)

  10. Lobster-eye infrared focusing optics

    Science.gov (United States)

    Grubsky, Victor; Gertsenshteyn, Michael; Jannson, Tomasz

    2006-08-01

    We propose a new imaging device for the long infrared spectral range, inspired by the natural eye of a lobster. Such a lobster-eye lens is composed of reflecting channels with a square cross section capable of wide angle of view and practically omni-directional imaging. As in large-aperture lenses, aberrations can significantly degrade the image. We show two methods of reducing aberrations: by selecting proper material for the mirrors and by making channels with absorbing sections.

  11. A comparison of two methods of logMAR visual acuity data scoring for statistical analysis

    Directory of Open Access Journals (Sweden)

    O. A. Oduntan

    2009-12-01

    Full Text Available The purpose of this study was to compare two methods of logMAR visual acuity (VA scoring. The two methods are referred to as letter scoring (method 1 and line scoring (method 2. The two methods were applied to VA data obtained from one hundred and forty (N=140 children with oculocutaneous albinism. Descriptive, correlation andregression statistics were then used to analyze the data.  Also, where applicable, the Bland and Altman analysis was used to compare sets of data from the two methods.  The right and left eyes data were included in the study, but because the findings were similar in both eyes, only the results for the right eyes are presented in this paper.  For method 1, the mean unaided VA (mean UAOD1 = 0.39 ±0.15 logMAR. The mean aided (mean ADOD1 VA = 0.50 ± 0.16 logMAR.  For method 2, the mean unaided (mean UAOD2 VA = 0.71 ± 0.15 logMAR, while the mean aided VA (mean ADOD2 = 0.60 ± 0.16 logMAR. The range and mean values of the improvement in VA for both methods were the same. The unaided VAs (UAOD1, UAOD2 and aided (ADOD1, ADOD2 for methods 1 and 2 correlated negatively (Unaided, r = –1, p<0.05, (Aided, r = –1, p<0.05.  The improvement in VA (differences between the unaided and aided VA values (DOD1 and DOD2 were positively correlated (r = +1, p <0.05. The Bland and Altman analyses showed that the VA improvement (unaided – aided VA values (DOD1 and DOD2 were similar for the two methods. Findings indicated that only the improvement in VA could be compared when different scoring methods are used. Therefore the scoring method used in any VA research project should be stated in the publication so that appropriate comparisons could be made by other researchers.

  12. An eye movement study for identification of suitable font characters for presentation on a computer screen.

    Science.gov (United States)

    Banerjee, Jayeeta; Majumdar, Dhurjati; Majumdar, Deepti; Pal, Madhu Sudan

    2010-06-01

    We are experiencing a shifting of media: from the printed paper to the computer screen. This transition is modifying the process of how we read and understand a text. It is very difficult to conclude on suitability of font characters based upon subjective evaluation method only. Present study evaluates the effect of font type on human cognitive workload during perception of individual alphabets on a computer screen. Twenty six young subjects volunteered for this study. Here, subjects have been shown individual characters of different font types and their eye movements have been recorded. A binocular eye movement recorder was used for eye movement recording. The results showed that different eye movement parameters such as pupil diameter, number of fixations, fixation duration were less for font type Verdana. The present study recommends the use of font type Verdana for presentation of individual alphabets on various electronic displays in order to reduce cognitive workload.

  13. Proteomic analysis of tears following acupuncture treatment for menopausal dry eye disease by two-dimensional nano-liquid chromatography coupled with tandem mass spectrometry.

    Science.gov (United States)

    Liu, Qingyu; Liu, Junling; Ren, Chengda; Cai, Wenting; Wei, Qingquan; Song, Yi; Yu, Jing

    2017-01-01

    The purpose of this study was to investigate whether acupuncture is effective at treating dry eye disease among postmenopausal women and to identify the possible mechanisms. Twenty-eight postmenopausal women with dry eye disease were randomly divided into two groups: an acupuncture plus artificial tears (AC + AT) group and an artificial tears (AT) only group. After baseline examination of clinical parameters and tear sample collection, each patient received the designated modality of topical therapy for 2 months. Post-treatment documentation of clinical parameters was recorded, and tear samples were collected. Tear samples from the AC + AT group were subjected to two-dimensional nano-liquid chromatography coupled with tandem mass spectrometry (2D nano-LC-MS/MS). Western blot analysis was also performed on tear samples from both groups. After treatment, the Ocular Surface Disease Index scores, symptom assessment scores, scores of sign assessment, and tear break-up time were significantly improved in both groups ( P =0.000). Symptom assessment scores were significantly improved in the AC + AT group ( P =0.000) compared with the AT group. 2D nano-LC-MS/MS identified 2,411 proteins, among which 142 were downregulated and 169 were upregulated. After combined AC + AT treatment, the abundance of secreted proteins was increased, whereas that of cytoplasmic proteins decreased (Pearson's χ 2 test, P =0.000, P =0.000, respectively). Proteins involved in immunity and regulation were also more abundant (Pearson's χ 2 test, P =0.040, P =0.016, respectively), while components and proliferation-related proteins were downregulated (Pearson's χ 2 test, P =0.003, P =0.011, respectively). AC + AT treatment increased protein synthesis and secretion, and improved clinical symptoms. These results indicate that acupuncture may be a complimentary therapy for treating postmenopausal dry eye disease.

  14. Patient satisfaction regarding eye care services at tertiary hospital of central India

    Directory of Open Access Journals (Sweden)

    Anand Sudhan

    2011-01-01

    Study Design : Descriptive study. Materials and Methods : This study was conducted between September 2005 and June 2006. Patients attending the eye clinic of Sadguru Netra Chikitsalaya, Chitrakoot, Madhya Pradesh, India, and admitted as in-patients in this hospital were our study population. Randomly selected patients were interviewed by trained staff. Close-ended questionnaire was used to conduct these structured interviews. Their responses were grouped into one of five categories and evaluated to determine satisfaction for different components of eye care services. Results : Three hundred and twenty persons were interviewed. The satisfaction was of excellent grade among 77 (48.1% patients attending clinic and 156 (97.5% patients who were admitted in the hospital. The participants expressed dissatisfaction for the long waiting period in clinics, poor cleanliness, and insufficient toilet facilities. Those admitted in the hospital felt that food facilities were less than the expected quality. Child-friendly facilities received high satisfaction scores. Conclusion : Although eye care services both in clinics and in the wards were satisfactory according to the end-users, there are scopes for improvement. Patient satisfaction surveys should be encouraged in hospitals for better accountability and also for strengthening the quality of eye care services.

  15. Eye tracking a comprehensive guide to methods and measures

    CERN Document Server

    Holmqvist, Kenneth; Andersson, Richard; Dewhurst, Richard; Jarodzka, Halszka; Weijer, Joost van de

    2011-01-01

    We make 3-5 eye movements per second, and these movements are crucial in helping us deal with the vast amounts of information we encounter in our everyday lives. In recent years, thanks to the development of eye tracking technology, there has been a growing interest in monitoring and measuring these movements, with a view to understanding how we attend to and process the visual information we encounter Eye tracking as a research tool is now more accessible than ever, and is growing in popularity amongst researchers from a whole host of different disciplines. Usability analysts, sports scientists, cognitive psychologists, reading researchers, psycholinguists, neurophysiologists, electrical engineers, and others, all have a vested interest in eye tracking for different reasons. The ability to record eye-movements has helped advance our science and led to technological innovations. However, the growth of eye tracking in recent years has also presented a variety of challenges - in particular the issue of how to d...

  16. Evaluation of Occupational Closed Globe Eye Injuries

    Directory of Open Access Journals (Sweden)

    Berna Akova-Budak

    2016-01-01

    Full Text Available Aim: To evaluate closed glob injuries related to occupational accidents of patients who had official occupational accident records. Material and Method: The medical records of patients with ocular injuries who referred to Department of Ophthalmology or emergency of Uludag University, School of Medicine between January 2010 and December 2013 with official occupational accident report were retrospectively reviewed. The patients with closed globe injuries following trauma were included. Age, sex, the injured eye, the cause of the trauma, whether the precautions were taken or not by the patient, the damage due to trauma were recorded. Results: According to the official records, 108 patients referred to our clinic with closed globe injury related to occupational accident. One hundred twenty eyes of 108 patients ( 2 females, 106 males were evaluated. The mean age of the patients was 33±8.6 years. The most frequent cause of injury was foreign bodies on the ocular surface followed by blunt trauma. The mean age of the patients injured with foreign bodies was found to be significantly lower than the patients injured with blunt objects (p=0.039. Thirteen patients reported that they had used preventive equipment. Discussion: It is of utmost importance that the awareness of the workers should be raised and they should be educated about the use of preventive equipment to prevent the occupational eye injuries. The education of particularly the younger patients about the occupational injuries when they begin to work may decrease the rate of occupational accident related eye injuries.

  17. Knowledge, Attitude, and Perception of Barriers for Eye Care among Diabetic Persons Registered at Employee Health Department of a Tertiary Eye Hospital of Central Saudi Arabia

    Science.gov (United States)

    Al-Alawi, Abeer; Al-Hassan, Arif; Chauhan, Deepti; Al-Futais, Muneera; Khandekar, Rajiv

    2016-01-01

    Purpose: To evaluate the level of knowledge, attitudes, and barriers to diabetic retinopathy (DR) screening among diabetic healthcare staff at a tertiary eye hospital in central Saudi Arabia. Methods: This was a descriptive survey using a closed-ended questionnaire. A. 5-grade. Likert scale was used for responses to each question. Data were collected on patient demographics and the status of diabetes. Survey responses related to knowledge, attitude, and barriers were grouped. Results: The study sample was comprised of 45 diabetics employed at the hospital. The mean age was 49 ± 11 years and 33 diabetics were males. One-third of the study population was referred to the eye clinic for DR screening. DR screening was performed in 25% of diabetics over the previous year. Twenty-nine (64%; 95% confidence intervals: 50–78) participants had excellent knowledge of eyecare for diabetic complications. Thirteen percent of participants had a positive attitude toward periodic eye checkups. Travel distance to an eyecare unit, no referral from family physicians for annual eye checkups and the lack of availability of gender-specific eyecare professionals were the main perceived barriers. Conclusion: Annual DR screening needs to be promoted to primary healthcare providers and diabetic patients. Barriers should be addressed to improve the uptake of DR screening. PMID:26957842

  18. Quantitative Assessment of Eye Phenotypes for Functional Genetic Studies Using Drosophila melanogaster

    Directory of Open Access Journals (Sweden)

    Janani Iyer

    2016-05-01

    Full Text Available About two-thirds of the vital genes in the Drosophila genome are involved in eye development, making the fly eye an excellent genetic system to study cellular function and development, neurodevelopment/degeneration, and complex diseases such as cancer and diabetes. We developed a novel computational method, implemented as Flynotyper software (http://flynotyper.sourceforge.net, to quantitatively assess the morphological defects in the Drosophila eye resulting from genetic alterations affecting basic cellular and developmental processes. Flynotyper utilizes a series of image processing operations to automatically detect the fly eye and the individual ommatidium, and calculates a phenotypic score as a measure of the disorderliness of ommatidial arrangement in the fly eye. As a proof of principle, we tested our method by analyzing the defects due to eye-specific knockdown of Drosophila orthologs of 12 neurodevelopmental genes to accurately document differential sensitivities of these genes to dosage alteration. We also evaluated eye images from six independent studies assessing the effect of overexpression of repeats, candidates from peptide library screens, and modifiers of neurotoxicity and developmental processes on eye morphology, and show strong concordance with the original assessment. We further demonstrate the utility of this method by analyzing 16 modifiers of sine oculis obtained from two genome-wide deficiency screens of Drosophila and accurately quantifying the effect of its enhancers and suppressors during eye development. Our method will complement existing assays for eye phenotypes, and increase the accuracy of studies that use fly eyes for functional evaluation of genes and genetic interactions.

  19. CUE: counterfeit-resistant usable eye movement-based authentication via oculomotor plant characteristics and complex eye movement patterns

    Science.gov (United States)

    Komogortsev, Oleg V.; Karpov, Alexey; Holland, Corey D.

    2012-06-01

    The widespread use of computers throughout modern society introduces the necessity for usable and counterfeit-resistant authentication methods to ensure secure access to personal resources such as bank accounts, e-mail, and social media. Current authentication methods require tedious memorization of lengthy pass phrases, are often prone to shouldersurfing, and may be easily replicated (either by counterfeiting parts of the human body or by guessing an authentication token based on readily available information). This paper describes preliminary work toward a counterfeit-resistant usable eye movement-based (CUE) authentication method. CUE does not require any passwords (improving the memorability aspect of the authentication system), and aims to provide high resistance to spoofing and shoulder-surfing by employing the combined biometric capabilities of two behavioral biometric traits: 1) oculomotor plant characteristics (OPC) which represent the internal, non-visible, anatomical structure of the eye; 2) complex eye movement patterns (CEM) which represent the strategies employed by the brain to guide visual attention. Both OPC and CEM are extracted from the eye movement signal provided by an eye tracking system. Preliminary results indicate that the fusion of OPC and CEM traits is capable of providing a 30% reduction in authentication error when compared to the authentication accuracy of individual traits.

  20. Real-Time Control of a Video Game Using Eye Movements and Two Temporal EEG Sensors

    Directory of Open Access Journals (Sweden)

    Abdelkader Nasreddine Belkacem

    2015-01-01

    Full Text Available EEG-controlled gaming applications range widely from strictly medical to completely nonmedical applications. Games can provide not only entertainment but also strong motivation for practicing, thereby achieving better control with rehabilitation system. In this paper we present real-time control of video game with eye movements for asynchronous and noninvasive communication system using two temporal EEG sensors. We used wavelets to detect the instance of eye movement and time-series characteristics to distinguish between six classes of eye movement. A control interface was developed to test the proposed algorithm in real-time experiments with opened and closed eyes. Using visual feedback, a mean classification accuracy of 77.3% was obtained for control with six commands. And a mean classification accuracy of 80.2% was obtained using auditory feedback for control with five commands. The algorithm was then applied for controlling direction and speed of character movement in two-dimensional video game. Results showed that the proposed algorithm had an efficient response speed and timing with a bit rate of 30 bits/min, demonstrating its efficacy and robustness in real-time control.

  1. Phacoemulsificatıon in eyes wıth cataract and high myopia

    Directory of Open Access Journals (Sweden)

    Servet Cetinkaya

    2015-10-01

    Full Text Available ABSTRACTPurpose:To evaluate the outcomes and complications following phacoemulsification surgery in eyes with cataract and high myopia.Methods:We retrospectively evaluated the data of 43 eyes of 28 consecutive patients (12 males, 16 females with cataract and high myopia who had undergone phacoemulsification and intraocular lens (IOL implantation. The mean [± standard deviation (range] age of the patients was 59.20 ± 11.08 (39-77 years.Results:The frequency of nuclear cataract was significantly higher than that of other cataract types (P=0.003. The mean axial length was 28.97 ± 1.99 (26-33 mm and the mean IOL power was 5.09 ± 4.78 (-3.0 to +14.0 diopters (D. The mean preoperative spherical equivalent (SE was -16.48 ± 5.23 (-8.00 to -25.00 D and the mean postoperative SE was -1.46 ± 0.93 (0.00 to -3.00 D (P=0.00. The mean preoperative best-corrected visual acuity (BCVA was 0.91 ± 0.37 (0.30 to -1.50 logMAR and the mean postoperative BCVA was 0.29 ± 0.25 (0.00-1.00 logMAR (P=0.00. Twenty-two eyes (51.2% achieved the target postoperative refraction (±1.0 D. The eyes were divided into 3 groups according to the axial length. The mean biometric error was significantly higher in the group with the greatest axial length than in the other groups (P=0.007. Preoperative argon laser photocoagulation was performed in 7 eyes (16% on account of retinal tears, retinal holes, or lattice degeneration. Postoperatively, retinal tears developed in 2 eyes (4% and were treated with photocoagulation. One eye (2% developed retinal detachment postoperatively, with the patient consequently referred for retinal surgery. Postoperatively, posterior capsule opacities developed in 11 eyes (25%, with all cases treated by laser capsulotomy.Conclusions:Good postoperative outcomes following phacoemulsification surgery were observed in patients with cataract and high myopia. However, clinicians should be aware of the risk of postoperative retinal tears and rhegmatogenous

  2. Evaluation of Approaches to Analyzing Continuous Correlated Eye Data When Sample Size Is Small.

    Science.gov (United States)

    Huang, Jing; Huang, Jiayan; Chen, Yong; Ying, Gui-Shuang

    2018-02-01

    To evaluate the performance of commonly used statistical methods for analyzing continuous correlated eye data when sample size is small. We simulated correlated continuous data from two designs: (1) two eyes of a subject in two comparison groups; (2) two eyes of a subject in the same comparison group, under various sample size (5-50), inter-eye correlation (0-0.75) and effect size (0-0.8). Simulated data were analyzed using paired t-test, two sample t-test, Wald test and score test using the generalized estimating equations (GEE) and F-test using linear mixed effects model (LMM). We compared type I error rates and statistical powers, and demonstrated analysis approaches through analyzing two real datasets. In design 1, paired t-test and LMM perform better than GEE, with nominal type 1 error rate and higher statistical power. In design 2, no test performs uniformly well: two sample t-test (average of two eyes or a random eye) achieves better control of type I error but yields lower statistical power. In both designs, the GEE Wald test inflates type I error rate and GEE score test has lower power. When sample size is small, some commonly used statistical methods do not perform well. Paired t-test and LMM perform best when two eyes of a subject are in two different comparison groups, and t-test using the average of two eyes performs best when the two eyes are in the same comparison group. When selecting the appropriate analysis approach the study design should be considered.

  3. Methods to reduce intraocular pressure on secondary glaucoma after severe eye burns

    Directory of Open Access Journals (Sweden)

    A. V. Solovieva

    2014-07-01

    Full Text Available Purpose: Show the results of treatment of secondary glaucoma after severe eye burns.Methods: We observed 70 patients (108 eyes with severe burns the eyes and their consequences, secondary glaucoma was observed in 40 patients (58 eyes. All patients with secondary glaucoma received traditional antihypertensive therapy, with its failure to resort to antiglaucomatous surgery. Cataract extraction performed in 24 cases, 16 of them in combination with other surgery: the reconstruction of the anterior chamber, penetrating keratoplasty, sinustrabeculectomy, diode laser cyclocoagulation. Diode laser cy- clocoagulation performed 42 times in 8 of them in combination with other antiglaucomatous surgery: cataract surgery, reconstruction of the anterior chamber. Sinustrabeculectomy in patients with secondary glaucoma was performed in 7 cases, 4 of them with collagen implant drainage. Ahmed glaucoma drainage implant performed in 5 cases.Results: In 23 out of 58 (39.6% of long-term compensation glaucoma IOP was achieved antihypertensive therapy without sur- gery. After cataract extraction resistant compensated IOP was achieved in 10 cases, a temporary (1 to 42 months — in 11 cases, IOP is not reduced in 2 cases. After completing diode laser cyclocoagulation stable normalization of IOP occurred in 16 cases, the temporary (from 1 month to 2 years — in 20 cases, 4 cases of IOP reduction was not achieved. As a result sinustrabeculectomy in 4 cases IOP decreased, in one case the hypotensive effect is not there. After implantation Ahmed glaucoma valve in 2 cases was achieved stable normalization of IOP, in the 2 cases — the temporary; in 1 case developed endophthalmitis, and the device was removed.Conclusion: the immediate effect of antiglaucomatous treatment was 96.6%, but the high incidence of IOP decompensation (73.7% suggesting the need for continuous follow-up patients after severe eye burn injury, and a readiness to use other methods to reduce IOP.

  4. Methods to reduce intraocular pressure on secondary glaucoma after severe eye burns

    Directory of Open Access Journals (Sweden)

    A. V. Solovieva

    2012-01-01

    Full Text Available Purpose: Show the results of treatment of secondary glaucoma after severe eye burns.Methods: We observed 70 patients (108 eyes with severe burns the eyes and their consequences, secondary glaucoma was observed in 40 patients (58 eyes. All patients with secondary glaucoma received traditional antihypertensive therapy, with its failure to resort to antiglaucomatous surgery. Cataract extraction performed in 24 cases, 16 of them in combination with other surgery: the reconstruction of the anterior chamber, penetrating keratoplasty, sinustrabeculectomy, diode laser cyclocoagulation. Diode laser cy- clocoagulation performed 42 times in 8 of them in combination with other antiglaucomatous surgery: cataract surgery, reconstruction of the anterior chamber. Sinustrabeculectomy in patients with secondary glaucoma was performed in 7 cases, 4 of them with collagen implant drainage. Ahmed glaucoma drainage implant performed in 5 cases.Results: In 23 out of 58 (39.6% of long-term compensation glaucoma IOP was achieved antihypertensive therapy without sur- gery. After cataract extraction resistant compensated IOP was achieved in 10 cases, a temporary (1 to 42 months — in 11 cases, IOP is not reduced in 2 cases. After completing diode laser cyclocoagulation stable normalization of IOP occurred in 16 cases, the temporary (from 1 month to 2 years — in 20 cases, 4 cases of IOP reduction was not achieved. As a result sinustrabeculectomy in 4 cases IOP decreased, in one case the hypotensive effect is not there. After implantation Ahmed glaucoma valve in 2 cases was achieved stable normalization of IOP, in the 2 cases — the temporary; in 1 case developed endophthalmitis, and the device was removed.Conclusion: the immediate effect of antiglaucomatous treatment was 96.6%, but the high incidence of IOP decompensation (73.7% suggesting the need for continuous follow-up patients after severe eye burn injury, and a readiness to use other methods to reduce IOP.

  5. Ipsiversive ictal eye deviation in inferioposterior temporal lobe epilepsy-Two SEEG cases report.

    Science.gov (United States)

    Zhang, Wei; Liu, Xingzhou; Zuo, Lijun; Guo, Qiang; Chen, Qi; Wang, Yongjun

    2017-02-21

    Versive seizure characterized by conjugate eye movement during epileptic seizure has been considered commonly as one of the most valuable semiological signs for epilepsy localization, especially for frontal lobe epilepsy. However, the lateralizing and localizing significance of ictaleye deviation has been questioned by clinical observation of a series of focal epilepsy studies, including frontal, central, temporal, parietal and occipital epilepsy. Two epileptic cases characterized by ipsiversive eye deviation as initial clinical sign during the habitual epileptic seizures are presented in this paper. The localization of the epileptogenic zone of both of the cases has been confirmed as inferioposterior temporal region by the findings of ictalstereoelectroencephalography (SEEG) and a good result after epileptic surgery. Detailed analysis of the exact position of the key contacts of the SEEG electrodes identified the overlap between the location of the epileptogenic zone and human MT/MST complex, which play a crucial role in the control of smooth pursuit eye movement. Ipsiversive eye deviation could be the initial clinical sign of inferioposterior temporal lobe epilepsy and attribute to the involvement of human MT/MST complex, especially human MST whichwas located on the anterior/dorsal bank of the anterior occipital sulcus (AOS).

  6. A retrospective study of low-vision cases in an Indian tertiary eye-care hospital

    Directory of Open Access Journals (Sweden)

    Khan Sarfaraz

    2000-01-01

    Full Text Available Purpose:To obtain data on the characteristics of low-vision patients seen at a tertiary eye care hospital in India. Methods:Records of 410 patients were retrospectively reviewed at the Centre for Sight Enhancement, L.V.Prasad Eye Institute, Hyderabad, India. Patients underwent a comprehensive clinical low-vision examination. Data obtained included age, gender, consangunity, visual acuity, visual fields, ocular conditions causing low vision and types of low-vision devices and methods prescribed. Results:Two hundred and ninety seven (72% of 450 patients were male. One-fifth were in the 11-20 years age group (21%. Visual acuity in the better eye was <6/18 - 6/60 in almost half these patients (49.3%. One hundred and twenty two patients (29.9% referred with a visual acuity of ≥ 6/18, either had difficulty in reading normal print or had restricted visual fields. The main causes for low vision were: retinitis pigmentosa (19%, diabetic retinopathy (13%, Macular diseases (17.7%, and degenerative myopia (9%. Visual rehabilitation was achieved using accurate correction of ametropia (174 patients, approach magnification (74 patients and telescopes (45 patients for recognising faces, watching television and board work. Spectacle magnifiers (187 patients, hand/stand magnifiers (9 patients, closed-circuit television (3 patients, overhead illumination lamp (143 patients and reading stand (24 patients were prescribed for reading tasks. Light control devices (146 patients were used for glare control, and cane (128 patients and flashlight (50 patients for mobility. Patients were trained in activities to improve their daily living skills, (54 patients; counselled in environmental modification (144 patients and ancillary care (63 patients for educational and vocational needs. Conclusion:Data obtained from this study elucidates the characteristics of low-vision patients. This information is likely to help in the development of appropriate low vision services.

  7. Quality indicators for eye bank

    Directory of Open Access Journals (Sweden)

    Manisha Acharya

    2018-01-01

    Full Text Available Purpose: The aim of this study is to identify quality indicators of the eye bank and validate their effectivity. Methods: Adverse reaction rate, discard rate, protocol deviation rate, and compliance rate were defined as Quality Indicators of the eye bank. These were identified based on definition of quality that captures two dimensions – “result quality” and “process quality.” The indicators were measured and tracked as part of quality assurance (QA program of the eye bank. Regular audits were performed to validate alignment of standard operating procedures (SOP with regulatory and surgeon acceptance standards and alignment of activities performed in the eye bank with the SOP. Prospective study of the indicators was performed by comparing their observed values over the period 2011–2016. Results: Adverse reaction rate decreased more than 8-fold (from 0.61% to 0.07%, discard rate decreased and stabilized at 30%, protocol deviation rate decreased from 1.05% to 0.08%, and compliance rate reported by annual quality audits improved from 59% to 96% at the same time. In effect, adverse reaction rate, discard rate, and protocol deviation rate were leading indicators, and compliance rate was the trailing indicator. Conclusion: These indicators fulfill an important gap in available literature on QA in eye banking. There are two ways in which these findings can be meaningful. First, eye banks which are new to quality measurement can adopt these indicators. Second, eye banks which are already deeply engaged in quality improvement can test these indicators in their eye bank, thereby incorporating them widely and improving them over time.

  8. An Open Conversation on Using Eye-Gaze Methods in Studies of Neurodevelopmental Disorders

    Science.gov (United States)

    Venker, Courtney E.; Kover, Sara T.

    2015-01-01

    Purpose: Eye-gaze methods have the potential to advance the study of neurodevelopmental disorders. Despite their increasing use, challenges arise in using these methods with individuals with neurodevelopmental disorders and in reporting sufficient methodological detail such that the resulting research is replicable and interpretable. Method: This…

  9. Effect of tonicity on 22NaCl solution uptake by rabbit eye in vivo and in vitro

    International Nuclear Information System (INIS)

    Obenberger, J.; Bartosova, D.; Babicky, A.

    1979-01-01

    Solutions of 22 NaCl in saline or distilled water differ with respect to their ocular uptake. Studies were performed on eyes of living rabbits as well on the enucleated rabbit eyes. Chromatographic paper strips (15x2 mm) were soaked in both solutions, stretched over the cornea and left in contact for 1 min. Radioactivities of paper strips and rabbit eyes were measured and the ocular uptake of 22 Na was expressed as percentual values of the total radioactivities contained in the paper strips before their application to the corneal surface. Values of the ocular uptake of 22 NaCl solved in distilled water exceeded more than twice the values found in experiments where 22 Na solution in saline was used. The use of carrier-free 22 NaCl solutions in distilled water is recommended for the method measuring the ocular uptake hydrodynamics on basis of ocular 22 Na clearance. Uptake of 22 Na in enucleated eyes was twenty-five per cent higher in comparison with the eyes of living rabitts. (author)

  10. [Guiding-qi acupuncture for dry eye syndrome].

    Science.gov (United States)

    Xie, Wenzhang; Zeng, Liang; Tao, Ying; Zhou, Yingfan; Zhao, Ran; Huang, Xinyun; Hou, Wenguang; Zhang, Ren; Zong, Lei

    2018-02-12

    To observe the clinical efficacy differences between different needling methods for dry eye syndrome. Sixty patients of dry eye syndrome were randomly divided into an observation group and a control group, 30 cases (60 eyes) in each group. Shangjingming (Extra), Xiajingming (Extra), Tongziliao (GB 1), Cuanzhu (BL 2), Fengchi (GB 20), Hegu (LI 4), Sanyinjiao (SP 6), Taixi (KI 3) and Taichong (LR 3) were selected in the two groups. The control group was treated with conventional acupuncture, while the observation group was treated with guiding- qi acupuncture. Electroacupuncture (EA) was used at bilateral Tongziliao (GB1) and Cuanzhu (BL 2), 30 min per treatment. The treatment was given three times per week. Totally 1-month treatment (12 treatments) was given. The eye symptom score, breakup time of tear film (BUT), Schirmer Ⅰ test (SⅠT) and visual analogue scale (VAS) score were compared before and after treatment in the two groups. The clinical efficacy was compared between the two groups. Compared before treatment, the eye symptom score, BUT, SⅠT and VAS score were improved after treatment in the two groups (all P eye symptom score and SⅠT in the observation group were superior to those in the control group (both P 0.05). The total effective rate was 86.7% (52/60) in the observation group, which was superior to 73.3% (44/60) in the control group ( P dry eye syndrome, and the efficacy of guiding- qi acupuncture combined with EA is superior to that of conventional EA.

  11. An eye model for computational dosimetry using a multi-scale voxel phantom

    International Nuclear Information System (INIS)

    Caracappa, P.F.; Rhodes, A.; Fiedler, D.

    2013-01-01

    The lens of the eye is a radiosensitive tissue with cataract formation being the major concern. Recently reduced recommended dose limits to the lens of the eye have made understanding the dose to this tissue of increased importance. Due to memory limitations, the voxel resolution of computational phantoms used for radiation dose calculations is too large to accurately represent the dimensions of the eye. A revised eye model is constructed using physiological data for the dimensions of radiosensitive tissues, and is then transformed into a high-resolution voxel model. This eye model is combined with an existing set of whole body models to form a multi-scale voxel phantom, which is used with the MCNPX code to calculate radiation dose from various exposure types. This phantom provides an accurate representation of the radiation transport through the structures of the eye. Two alternate methods of including a high-resolution eye model within an existing whole body model are developed. When the Lattice Overlay method, the simpler of the two to define, is utilized, the computational penalty in terms of speed is noticeable and the figure of merit for the eye dose tally decreases by as much as a factor of two. When the Voxel Substitution method is applied, the penalty in speed is nearly trivial and the impact on the tally figure of merit is comparatively smaller. The origin of this difference in the code behavior may warrant further investigation

  12. Treatment of dysfunctionally stored experiences with the method Eye Movement Desensitization and Reprocessing – EMDR

    Directory of Open Access Journals (Sweden)

    Robert Cvetek

    2002-09-01

    Full Text Available In this paper a new therapeutic method called EMDR (Eye Movement Desensitization and Reprocessing is described. The method was formed mainly for treatment of posttraumatic stress disorder, but there are also some reports about success with other mental disorders. The theoretical base of EMDR and especially the accelerated information processing model, the concept of memory networks and the explanations of effects of eye movements are presented. The process of EMDR is also described.

  13. Dry eye signs and symptoms in night-time workers

    OpenAIRE

    Ali Makateb; Hamed Torabifard

    2017-01-01

    Purpose: To determine the effect of night-time working on dry eye signs and symptoms. Methods: A total of 50 healthy subjects completed a dry eye questionnaire and underwent clinical examinations including basic Schirmer's test and tear breakup time (TBUT) test on two consecutive days, before and after the night shift (12-hrs night-shift). Results: All dry eye symptoms were aggravated significantly after the night shift (P 

  14. A rating scale is a proper method to evaluate changes in quality of life due to dry eye symptoms.

    Science.gov (United States)

    Xue, Wenwen; Xu, Xian; Zou, Haidong

    2018-02-07

    To determine which utility value assessment method is more suitable to evaluate changes in the quality of life due to dry eye symptoms. Dry eye outpatients with a presenting visual acuity of 20/25 or better in the worse-seeing eye were recruited. Presenting distance visual acuity, tear film break-up time, Schirmer I test and fluorescein were assessed. The severity of dry eye symptoms was assessed using the Ocular Surface Disease Index (OSDI), and utility values were measured using the time trade-off (TTO), standard gamble (SG1 and SG2) and rating scale (RS) methods. Different utility values were compared with each other. The most appropriate utility value method to evaluate quality-of-life changes solely due to dry eye symptoms is determined by calculating the correlation between the OSDI score and different utility values. A total of 104 patients were enrolled. The three sections of OSDI in the order of high to low scores were as follows: "environmental trigger," "eye discomfort" and "visual function." The utility scores measured with TTO, SG1, SG2 and RS were 0.95 ± 0.11, 0.96 ± 0.10, 0.99 ± 0.07 and 0.89 ± 0.10, respectively. The utility scores evaluated by the TTO, SG1, SG2 and RS methods were significantly different from each other (p eye discomfort" section scores (p dry eye symptoms.

  15. Assessment of the eye irritation potential of chemicals: A comparison study between two test methods based on human 3D hemi-cornea models.

    Science.gov (United States)

    Tandon, R; Bartok, M; Zorn-Kruppa, M; Brandner, J M; Gabel, D; Engelke, M

    2015-12-25

    We have recently developed two hemi-cornea models (Bartok et al., Toxicol in Vitro 29, 72, 2015; Zorn-Kruppa et al. PLoS One 9, e114181, 2014), which allow the correct prediction of eye irritation potential of chemicals according to the United Nations globally harmonized system of classification and labeling of chemicals (UN GHS). Both models comprise a multilayered epithelium and a stroma with embedded keratocytes in a collagenous matrix. These two models were compared, using a set of fourteen test chemicals. Their effects after 10 and 60 minutes (min) exposure were assessed from the quantification of cell viability using the MTT reduction assay. The first approach separately quantifies the damage inflicted to the epithelium and the stroma. The second approach quantifies the depth of injury by recording cell death as a function of depth. The classification obtained by the two models was compared to the Draize rabbit eye test and an ex vivo model using rabbit cornea (Jester et al. Toxicol in Vitro. 24, 597-604, 2010). With a 60 min exposure, both of our models are able to clearly differentiate UN GHS Category 1 and UN GHS Category 2 test chemicals. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. SU-G-IeP4-09: Method of Human Eye Aberration Measurement Using Plenoptic Camera Over Large Field of View

    International Nuclear Information System (INIS)

    Lv, Yang; Wang, Ruixing; Ma, Haotong; Zhang, Xuanzhe; Ning, Yu; Xu, Xiaojun

    2016-01-01

    Purpose: The measurement based on Shack-Hartmann wave-front sensor(WFS), obtaining both the high and low order wave-front aberrations simultaneously and accurately, has been applied in the detection of human eyes aberration in recent years. However, Its application is limited by the small field of view (FOV), slight eye movement leads the optical bacon image exceeds the lenslet array which result in uncertain detection error. To overcome difficulties of precise eye location, the capacity of detecting eye wave-front aberration over FOV much larger than simply a single conjugate Hartmann WFS accurately and simultaneously is demanded. Methods: Plenoptic camera’s lenslet array subdivides the aperture light-field in spatial frequency domain, capture the 4-D light-field information. Data recorded by plenoptic cameras can be used to extract the wave-front phases associated to the eyes aberration. The corresponding theoretical model and simulation system is built up in this article to discuss wave-front measurement performance when utilizing plenoptic camera as wave-front sensor. Results: The simulation results indicate that the plenoptic wave-front method can obtain both the high and low order eyes wave-front aberration with the same accuracy as conventional system in single visual angle detectionand over FOV much larger than simply a single conjugate Hartmann systems. Meanwhile, simulation results show that detection of eye aberrations wave-front in different visual angle can be achieved effectively and simultaneously by plenoptic method, by both point and extended optical beacon from the eye. Conclusion: Plenoptic wave-front method possesses the feasibility in eye aberrations wave-front detection. With larger FOV, the method can effectively reduce the detection error brought by imprecise eye location and simplify the eye aberrations wave-front detection system comparing with which based on Shack-Hartmann WFS. Unique advantage of the plenoptic method lies in obtaining

  17. SU-G-IeP4-09: Method of Human Eye Aberration Measurement Using Plenoptic Camera Over Large Field of View

    Energy Technology Data Exchange (ETDEWEB)

    Lv, Yang; Wang, Ruixing; Ma, Haotong; Zhang, Xuanzhe; Ning, Yu; Xu, Xiaojun [College of Optoelectronic Science and Engineering, National University of Defense Technology, Changsha (China)

    2016-06-15

    Purpose: The measurement based on Shack-Hartmann wave-front sensor(WFS), obtaining both the high and low order wave-front aberrations simultaneously and accurately, has been applied in the detection of human eyes aberration in recent years. However, Its application is limited by the small field of view (FOV), slight eye movement leads the optical bacon image exceeds the lenslet array which result in uncertain detection error. To overcome difficulties of precise eye location, the capacity of detecting eye wave-front aberration over FOV much larger than simply a single conjugate Hartmann WFS accurately and simultaneously is demanded. Methods: Plenoptic camera’s lenslet array subdivides the aperture light-field in spatial frequency domain, capture the 4-D light-field information. Data recorded by plenoptic cameras can be used to extract the wave-front phases associated to the eyes aberration. The corresponding theoretical model and simulation system is built up in this article to discuss wave-front measurement performance when utilizing plenoptic camera as wave-front sensor. Results: The simulation results indicate that the plenoptic wave-front method can obtain both the high and low order eyes wave-front aberration with the same accuracy as conventional system in single visual angle detectionand over FOV much larger than simply a single conjugate Hartmann systems. Meanwhile, simulation results show that detection of eye aberrations wave-front in different visual angle can be achieved effectively and simultaneously by plenoptic method, by both point and extended optical beacon from the eye. Conclusion: Plenoptic wave-front method possesses the feasibility in eye aberrations wave-front detection. With larger FOV, the method can effectively reduce the detection error brought by imprecise eye location and simplify the eye aberrations wave-front detection system comparing with which based on Shack-Hartmann WFS. Unique advantage of the plenoptic method lies in obtaining

  18. Photogrammetry System and Method for Determining Relative Motion Between Two Bodies

    Science.gov (United States)

    Miller, Samuel A. (Inventor); Severance, Kurt (Inventor)

    2014-01-01

    A photogrammetry system and method provide for determining the relative position between two objects. The system utilizes one or more imaging devices, such as high speed cameras, that are mounted on a first body, and three or more photogrammetry targets of a known location on a second body. The system and method can be utilized with cameras having fish-eye, hyperbolic, omnidirectional, or other lenses. The system and method do not require overlapping fields-of-view if two or more cameras are utilized. The system and method derive relative orientation by equally weighting information from an arbitrary number of heterogeneous cameras, all with non-overlapping fields-of-view. Furthermore, the system can make the measurements with arbitrary wide-angle lenses on the cameras.

  19. A new 3D reconstituted human corneal epithelium model as an alternative method for the eye irritation test.

    Science.gov (United States)

    Jung, Kyoung-Mi; Lee, Su-Hyon; Ryu, Yang-Hwan; Jang, Won-Hee; Jung, Haeng-Sun; Han, Ju-Hee; Seok, Seung-Hyeok; Park, Jae-Hak; Son, Youngsook; Park, Young-Ho; Lim, Kyung-Min

    2011-02-01

    Many efforts are being made to develop new alternative in vitro test methods for the eye irritation test. Here we report a new reconstructed human corneal epithelial model (MCTT HCE model) prepared from primary-cultured human limbal epithelial cells as a new alternative in vitro eye irritation test method. In histological and immunohistochemical observation, MCTT HCE model displayed a morphology and biomarker expressions similar to intact human cornea. Moreover, the barrier function was well preserved as measured by high transepithelial electrical resistance, effective time-50 for Triton X-100, and corneal thickness. To employ the model as a new alternative method for eye irritation test, protocol refinement was performed and optimum assay condition was determined including treatment time, treatment volume, post-incubation time and rinsing method. Using the refined protocol, 25 reference chemicals with known eye irritation potentials were tested. With the viability cut-off value at 50%, chemicals were classified to irritant or non-irritant. When compared with GHS classification, the MCTT HCE model showed the accuracy of 88%, sensitivity of 100% and specificity of 77%. These results suggest that the MCTT HCE model might be useful as a new alternative eye irritation test method. Copyright © 2010 Elsevier Ltd. All rights reserved.

  20. Herpetic Eye Disease in a Public Eye Hospital in Nigeria | Nwosu ...

    African Journals Online (AJOL)

    Objective: To determine the aetiology, pattern and complications of herpetic eye disease seen at the Guinness Eye Centre, Onitsha, Nigeria. Materials and Methods: The case files of all patients with herpetic eye disease who presented at the centre between January 1998 and December 2003 were reviewed. Information on ...

  1. Comparison of eye morphology and retinal topography in two species of new world vultures (Aves: Cathartidae)

    DEFF Research Database (Denmark)

    Lisney, Thomas J.; Stecyk, Karyn; Kolominsky, Jeffrey

    2013-01-01

    Vultures are highly reliant on their sensory systems for the rapid detection and localization of carrion before other scavengers can exploit the resource. In this study, we compared eye morphology and retinal topography in two species of New World vultures (Cathartidae), turkey vultures (Cathartes...... aura), with a highly developed olfactory sense, and black vultures (Coragyps atratus), with a less developed sense of olfaction. We found that eye size relative to body mass was the same in both species, but that black vultures have larger corneas relative to eye size than turkey vultures. However......, the overall retinal topography, the total number of cells in the retinal ganglion cell layer, peak and average cell densities, cell soma area frequency distributions, and the theoretical peak anatomical spatial resolving power were the same in both species. This suggests that the visual systems of these two...

  2. Efficacy of topical cyclosporine 0.05% eye drops in the treatment of dry eyes

    OpenAIRE

    Haitham Y Al-Nashar

    2015-01-01

    Purpose The aim of the present study was to evaluate the effectiveness of cyclosporine 0.05% in the treatment of dry-eye disease. Patients and methods A total of 35 eyes of 20 patients with dry-eye disease were included in the present study. Ten patients (20 eyes) had dry eyes associated with systemic rheumatologic disease (Sjögren′s syndrome), five patients (10 eyes) had dry eyes after undergoing laser in-situ keratomileusis, and five patients (five eyes) had dry eyes after cataract...

  3. The effects of two different types of bandage contact lenses on the healthy canine eye.

    Science.gov (United States)

    Braus, Barbara Katharina; Riedler, Daniela; Tichy, Alexander; Spergser, Joachim; Schwendenwein, Ilse

    2018-02-06

    To compare two types of bandage contact lenses on the healthy canine eye. Six healthy Beagles. Two different types of bandage contact lenses (single sized human silicone contact lens 'PureVision 2' (Bausch & Lomb Incorporated, Rochester, NY, USA) and specially designed veterinary hydrogel contact lens 'AcriVet Pat D' (Bausch & Lomb Incorporated) were placed in 12 eyes of healthy Beagle dogs. Retention times and the effects of the lenses regarding irritation of the eye, changes in tear production, impact of contact lenses on tonometric readings, and cytologic and microbiological alterations of the canine eye were investigated. Mean retention times for veterinary hydrogel lenses with special dimensions were significantly shorter (2 days) than for one size human silicon lenses (8.8 days). Irritation scores were overall low for both types of lenses apart from one human lens causing severe irritation and keratoconjunctivitis as a sequel to folding and displacement. Tear production remained stable in human contact lenses. Intraocular pressure readings with a contact lens in place were only slightly altered; the most accurate readings were obtained through a human lens with an applanation tonometer. Cytology revealed a slight, nonsignificant increase in neutrophilic granulocytes with both types of lenses; the microflora did not change significantly. Human silicone lenses have significantly longer retention times and are less expensive than veterinary hydrogel lenses. In regard to irritation, bacterial growth and inflammation, both types of lenses can be recommended for use in canine eyes. © 2018 American College of Veterinary Ophthalmologists.

  4. The influence of protein free calf blood extract eye gel on dry eye after pterygium surgery

    Directory of Open Access Journals (Sweden)

    Cai-Ni Ji

    2013-07-01

    Full Text Available AIM: To investigate the influence of protein free calf blood extract eye gel on dry eye after pterygium surgery. METHODS: Thirty six patients(40 eyeswith primary nasal pterygium were enrolled in this study, which were divided into study group and control group randomly, with 20 eyes in each group. All patients received pterygium excision and limbal stem cell autograft surgery and tobramicin dexamethasone eye drops after surgery. Patients of the study group received protein free calf blood extract eye gel while those of the control group received 0.1% sodium hyaluronate eye drops furthermore. Ocular surface disease index(OSDIquestionnaire, tear film break-up time(BUTand Schirmer's Ⅰ test Ⅰ(SⅠtwere carried before and 3 months after surgery to evaluate the dry eye degree of the patients. RESULTS: There was no statistical difference between the age, gender and size of the pterygium of the study and control groups preoperatively. There was no statistical difference between the OSDI(2.33±1.02 vs 2.32±0.93, BUT(8.80±2.48 vs 8.35±2.28seconds and SⅠt(4.30±2.30 vs 4.40±2.44of the two groups preoperatively. There was statistical difference between the OSDI(1.45±0.47 vs 1.81±0.60, BUT(11.20±2.07 vs 9.50±2.40seconds and SⅠt(8.35±3.13 vs 6.35±2.18of the two groups 3 months postoperatively, which was also different from that of the preoperative data correspondingly. CONCLUSION: Protein free calf blood extract eye gel could reduce the dry eye after pterygium surgery.

  5. Two Eyes, 3D: A New Project to Study Stereoscopy in Astronomy Education

    Science.gov (United States)

    Price, Aaron; SubbaRao, M.; Wyatt, R.

    2012-01-01

    "Two Eyes, 3D" is a 3-year NSF funded research project to study the educational impacts of using stereoscopic representations in informal settings. The project funds two experimental studies. The first is focused on how children perceive various spatial qualities of scientific objects displayed in static 2D and 3D formats. The second is focused on how adults perceive various spatial qualities of scientific objects and processes displayed in 2D and 3D movie formats. As part of the project, two brief high-definition films about variable stars will be developed. Both studies will be mixed-method and look at prior spatial ability and other demographic variables as covariates. The project is run by the American Association of Variable Star Observers, Boston Museum of Science and the Adler Planetarium and Astronomy Museum with consulting from the California Academy of Sciences. Early pilot results will be presented. All films will be released into the public domain, as will the assessment software designed to run on tablet computers (iOS or Android).

  6. The genetics of eye colours in an Italian population measured with an objective method for eye colour quantification

    DEFF Research Database (Denmark)

    Pietroni, C.; Andersen, J.D.; Johansen, P.

    2013-01-01

    Brown and blue eye colours are primarily explained by the single nucleotide polymorphism (SNP) HERC2 rs12913832. However, the genetics of eye colours that appear to be neither blue nor brown are not well understood. In this study, 230 unrelated Italian individuals were typed for 32 SNP loci...... in the iris region and calculated a Pixel Index of the Eye (PIE-score) that described the eye colours quantitatively. The PIE-score ranged from _1 to 1 (brown to blue). We investigated the association of the PIE-scores extracted from the eye images with the genotypes of the 32 pigmentary SNPs. We observed...

  7. TU-E-201-01: Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionists

    Energy Technology Data Exchange (ETDEWEB)

    Rehani, M. [Massachusetts General Hospital (United States)

    2015-06-15

    Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on

  8. TU-E-201-01: Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionists

    International Nuclear Information System (INIS)

    Rehani, M.

    2015-01-01

    Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on

  9. Uveal melanoma in the Saudi Arabian population: Two decades of management at the King Khaled Eye Specialist Hospital

    International Nuclear Information System (INIS)

    Alsuhaibani Adel H

    2009-01-01

    To present the experience of King Khaled Eye Specialist Hospital (KKESH) with uveal melanoma over the last two decades in a fashion similar to the result of the Collaborative Ocular Melanoma Study (COMS). Retrospective, non-comparative, interventional, case series. All patients were diagnosed with uveal melanoma at the King Khaled Eye Specialist Hospital (KKESH), Riyadh, Saudi Arabia from June 1983 to July 2005 and met the inclusion criteria of the COMS. A medical record review of clinical history, imaging studies, surgical procedures and treatment outcome was performed. Forty patients (24 males and 16 females) with uveal melanoma (average age 50 years; range 24-77 years) were included in the study; 28 (70%) were of Saudi Arabian descent and the remaining 12 (30%) patients were from neighboring Arab countries. Decreased vision was the main presenting complaint of 29 (72.5%) patients; the duration of this symptom was 3 months or more in 27 (67.5%) patients. The apical height of the tumor was 10 mm or more in nine (22.5%) of the affected eyes and the largest basal dimension was more than 16 mm in nine (22.5%) of the affected eyes. The posterior border of the tumor was 1-2 mmfrom the optic disc in three (7.5%) affected eyes. Primary enucleation was performed for 33 (82.5%) eyes, episcleral radiation plaque therapy for six (15%) of the eyes and endo resection of the uveal melanoma in one (2.5%) eye. Adjunct external beam radiation therapy was performed in two (5%) orbits for extrascleral extension. The histopathological diagnosis was available for 34 (84%) eyes in which surgery had been performed (33 patients underwent primary enucleation and one patient underwent endo resection of the uveal melanoma); 24 (70.6%) eyes had spindle cell and the remaining 10 (29.4%) had epithelioid or mixed cell types. Evidence of extraocular tumor extension was found in three eyes. The average follow-up was 33.7 months with a median of 19 months (range 0.5 months to 10 years). Two (5

  10. [Two cases of severe eye and cranial injuries due to firework explosions].

    Science.gov (United States)

    Saunte, J P; Trojaborg, N S; Nielsen, O A; Thygesen, J

    1999-12-20

    Two patients who sustained serious facial, cranial and eye trauma secondary to recreational fireworks injuries are reported. Initial assessment included axial and coronary computerized tomography, control of haemorrhage, debridement of wound and brain, and in one patient bilateral excenteration of the globe. Both patients suffered from intracranial haemorrhage, but both recovered without severe neurological sequelae.

  11. Efficacy and safety of short-term application of pranoprofen eye drops for senile patients with dry eyes

    Directory of Open Access Journals (Sweden)

    Yu-Chan Li

    2018-06-01

    Full Text Available AIM:To investigate the efficacy and safety of short-term application of pranoprofen eye drops in the treatment of dry eyes in senile patients. METHODS: Totally 100 elderly patients with dry eyes treated in our hospital from June 2016 to May 2017 were randomly divided into 2 groups. All cases were bilateral onset, and the right eyes were marked as the observation eyes. The 50 eyes in the observation group were treated with 1g/L pranoprofen eye drops combined with 1g/L sodium hyaluronate eye drops, while 50 in the control group were treated with 1g/L sodium hyaluronate eye drops. The results of Schirmer Ⅰ, ocular surface disease index(OSDI, break-up time(BUT, ocular surface staining(OSS, human leukocyte antigen-DR(HLA-DRand CD11b in conjunctival epithelial cells before and at 2wk after treatment, and adverse reactions in 2 groups were observed. RESULTS: Before treatment, results of Schirmer I, OSDI, BUT, OSS, HLA-DR and CD11b in the two groups were similar, there were no statistically significant differences(P>0.05. After treatment, OSDI, OSS, HLA-DR, CD11b significantly decreased, BUT significantly increased in both groups, the differences were statistically significant(PPPCONCLUSION: Short term application of pranoprofen eye drops can effectively enhance the efficacy in treating elderly patients with dry eyes, release clinical symptoms, and the therapeutic mechanism may be related to the inhibitory effect on HLA-DR.

  12. Treatment of Sjögren's syndrome dry eye using 0.03% tacrolimus eye drop: Prospective double-blind randomized study.

    Science.gov (United States)

    Moscovici, Bernardo Kaplan; Holzchuh, Ricardo; Sakassegawa-Naves, Fernando Eiji; Hoshino-Ruiz, Diego Ricardo; Albers, Marcos Bottene Villa; Santo, Ruth Miyuki; Hida, Richard Yudi

    2015-10-01

    To describe the clinical efficacy of the treatment of Sjögren's syndrome dry eye using 0.03% tacrolimus eye drop. Prospective double-blind randomized study. Institutional outpatient clinic. Forty-eight eyes of twenty-four patients with dry eye related to Sjögren syndrome were enrolled in this study. The patients were randomized in 2 groups: tacrolimus (n=14) and vehicle (n=10) group. The tacrolimus group received a vial containing tacrolimus 0.03% (almond oil as vehicle) and the other group received the almond oil vehicle. All patients were instructed to use the eye drops every 12h in the lower conjunctival sac. Schirmer I test, break-up-time (BUT), corneal fluorescein and Rose Bengal staining scores were evaluated in all patients one day before the treatment (baseline), 7, 14, 28 and 90 days after treatment with the eye drops. The average fluorescein and Rose Bengal scores improved statistically after 7 days of treatment and even more after 90 days. The average Schirmer I and BUT values were unchanged after 7, 14 and 21 days but did show an improvement relative to baseline after 28 days of treatment. Schirmer I, BUT, fluorescein and Rose Bengal did not show any statistical significance in the vehicle group. Topical 0.03% tacrolimus eye drop improved tear stability and ocular surface status in cases of inflammatory or SS-related dry eye. ClinicalTrials.gov Identifier: NCT01850979. Copyright © 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  13. Premotor neurons encode torsional eye velocity during smooth-pursuit eye movements

    Science.gov (United States)

    Angelaki, Dora E.; Dickman, J. David

    2003-01-01

    Responses to horizontal and vertical ocular pursuit and head and body rotation in multiple planes were recorded in eye movement-sensitive neurons in the rostral vestibular nuclei (VN) of two rhesus monkeys. When tested during pursuit through primary eye position, the majority of the cells preferred either horizontal or vertical target motion. During pursuit of targets that moved horizontally at different vertical eccentricities or vertically at different horizontal eccentricities, eye angular velocity has been shown to include a torsional component the amplitude of which is proportional to half the gaze angle ("half-angle rule" of Listing's law). Approximately half of the neurons, the majority of which were characterized as "vertical" during pursuit through primary position, exhibited significant changes in their response gain and/or phase as a function of gaze eccentricity during pursuit, as if they were also sensitive to torsional eye velocity. Multiple linear regression analysis revealed a significant contribution of torsional eye movement sensitivity to the responsiveness of the cells. These findings suggest that many VN neurons encode three-dimensional angular velocity, rather than the two-dimensional derivative of eye position, during smooth-pursuit eye movements. Although no clear clustering of pursuit preferred-direction vectors along the semicircular canal axes was observed, the sensitivity of VN neurons to torsional eye movements might reflect a preservation of similar premotor coding of visual and vestibular-driven slow eye movements for both lateral-eyed and foveate species.

  14. PERIPAPILLARY RETINAL NERVE FIBER THICKNESS CHANGES AFTER VITRECTOMY FOR EPIRETINAL MEMBRANE IN EYES WITH AND WITHOUT VITREOUS DETACHMENT.

    Science.gov (United States)

    Mariotti, Cesare; Nicolai, Michele; Longo, Antonio; Viti, Francesca; Bambini, Elisa; Saitta, Andrea; Pirani, Vittorio; Orsini, Emanuele; Baruffa, Daniela; Reibaldi, Michele

    2017-12-01

    To compare the changes in postoperative peripapillary retinal nerve fiber layer (p-RNFL) thickness after vitrectomy for epiretinal membrane in eyes with preexisting posterior vitreous detachment (PVD) and eyes with surgically induced PVD. This study included consecutive patients who underwent 25-gauge vitrectomy for epiretinal membrane. Eyes were divided, according to intraoperative PVD status, into a preexisting PVD group and surgically induced PVD group. Best-corrected visual acuity, p-RNFL thickness, and central retinal thickness were performed before and at 1, 3, and 6 months after surgery. One hundred and twenty eyes of 120 patients were enrolled: 64 eyes in the preexisting PVD group and 56 eyes in the surgically induced PVD group. In the preexisting PVD group at 6 months, the mean global p-RNFL thickness did not change, whereas it was reduced in the temporal sector (P = 0.034). In the surgically induced PVD group at 6 months, significant decreases were observed in global p-RNFL thickness (P = 0.027), temporal (P = 0.021), temporal inferior (P = 0.030), and nasal inferior sectors (P = 0.010). At 6 months, the two groups differed significantly in temporal (P PVD.

  15. Vitrectomy with internal limiting membrane peeling for macular hole in high myopia eyes

    Directory of Open Access Journals (Sweden)

    Chun-Mei Deng

    2015-08-01

    Full Text Available AIM: To compare the clinical effects between pars plana vitrectomy(PPVand PPV with internal limiting membrane peeling(ILMPfor macular hole in high myopia eyes. METHODS:The clinical data of 33 high myopia with macular hole patients(36 eyeswith or without retinal detachment caused by macular hole were retrospectively analyzed. The patients were divided into two groups according to different operation methods: 15 eyes in groupⅠhad undergone PPV; 21 eyes in groupⅡhad undergone PPV with ILMPP peeling. According to different conditions of patients,different auxiliary methods were accepted, such as silicone oil tamponade, C3F8 tamponade, photocoagulation, condensation, etc. The follow-up period was 3~12mo. Best corrected visual acuity(BCVA, macular hole closure rate and retinal reattachment rate were continuous checked after operation. Then we evaluated the outcome in the two groups by statistical analysis.RESULTS: The postoperative mean BCVA increased by 0.167 in group Ⅰand 0.456 in group Ⅱ than preoperative, the difference was significant(t=2.46,6.753; P=0.027,0.000. And the difference of BCVA improvement was significant between those two groups(t=-2.943, P=0.006. The macular hole closed in 7 eyes(46.67%in group Ⅰ,and 18 eyes(85.71%in group Ⅱ; The difference was significant between those two groups(χ2=6.287,P=0.025.Retinal reattachment was found in 11 eyes(91.67%in group Ⅰ and 19 eyes(94.73%in group Ⅱ. The difference was not significant between the two groups(χ2=0.856, P=0.418. CONCLUSION: PPV with ILMPP peeling for macular hole in high myopia eyes can obviously improve closure of macular hole and postoperative visual acuity. But the difference of retinal reattachment rate was not significant between peeling and unpeeling of ILMP.

  16. Comparison of Video Head Impulse Test (vHIT) Gains Between Two Commercially Available Devices and by Different Gain Analytical Methods.

    Science.gov (United States)

    Lee, Sang Hun; Yoo, Myung Hoon; Park, Jun Woo; Kang, Byung Chul; Yang, Chan Joo; Kang, Woo Suk; Ahn, Joong Ho; Chung, Jong Woo; Park, Hong Ju

    2018-06-01

    To evaluate whether video head impulse test (vHIT) gains are dependent on the measuring device and method of analysis. Prospective study. vHIT was performed in 25 healthy subjects using two devices simultaneously. vHIT gains were compared between these instruments and using five different methods of comparing position and velocity gains during head movement intervals. The two devices produced different vHIT gain results with the same method of analysis. There were also significant differences in the vHIT gains measured using different analytical methods. The gain analytic method that compares the areas under the velocity curve (AUC) of the head and eye movements during head movements showed lower vHIT gains than a method that compared the peak velocities of the head and eye movements. The former method produced the vHIT gain with the smallest standard deviation among the five procedures tested in this study. vHIT gains differ in normal subjects depending on the device and method of analysis used, suggesting that it is advisable for each device to have its own normal values. Gain calculations that compare the AUC of the head and eye movements during the head movements show the smallest variance.

  17. Two Eyes, 3D: Stereoscopic Design Principles

    Science.gov (United States)

    Price, Aaron; Subbarao, M.; Wyatt, R.

    2013-01-01

    Two Eyes, 3D is a NSF-funded research project about how people perceive highly spatial objects when shown with 2D or stereoscopic ("3D") representations. As part of the project, we produced a short film about SN 2011fe. The high definition film has been rendered in both 2D and stereoscopic formats. It was developed according to a set of stereoscopic design principles we derived from the literature and past experience producing and studying stereoscopic films. Study participants take a pre- and post-test that involves a spatial cognition assessment and scientific knowledge questions about Type-1a supernovae. For the evaluation, participants use iPads in order to record spatial manipulation of the device and look for elements of embodied cognition. We will present early results and also describe the stereoscopic design principles and the rationale behind them. All of our content and software is available under open source licenses. More information is at www.twoeyes3d.org.

  18. Combined fMRI- and eye movement-based decoding of bistable plaid motion perception.

    Science.gov (United States)

    Wilbertz, Gregor; Ketkar, Madhura; Guggenmos, Matthias; Sterzer, Philipp

    2018-05-01

    The phenomenon of bistable perception, in which perception alternates spontaneously despite constant sensory stimulation, has been particularly useful in probing the neural bases of conscious perception. The study of such bistability requires access to the observer's perceptual dynamics, which is usually achieved via active report. This report, however, constitutes a confounding factor in the study of conscious perception and can also be biased in the context of certain experimental manipulations. One approach to circumvent these problems is to track perceptual alternations using signals from the eyes or the brain instead of observers' reports. Here we aimed to optimize such decoding of perceptual alternations by combining eye and brain signals. Eye-tracking and functional magnetic resonance imaging (fMRI) was performed in twenty participants while they viewed a bistable visual plaid motion stimulus and reported perceptual alternations. Multivoxel pattern analysis (MVPA) for fMRI was combined with eye-tracking in a Support vector machine to decode participants' perceptual time courses from fMRI and eye-movement signals. While both measures individually already yielded high decoding accuracies (on average 86% and 88% correct, respectively) classification based on the two measures together further improved the accuracy (91% correct). These findings show that leveraging on both fMRI and eye movement data may pave the way for optimized no-report paradigms through improved decodability of bistable motion perception and hence for a better understanding of the neural correlates of consciousness. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. METHOD OF NON-CONTACT PHOTOLUMINESCENT DIAGNOSTICS OF THE EYE FIBROUS TUNIC CONDITION

    Directory of Open Access Journals (Sweden)

    S. Yu. Petrov

    2018-01-01

    Full Text Available Non-contact optical diagnostics of structural disorders of the eye has a number of advantages: high speed, accuracy and a large range of parameters available for analysis. The paper presents the results of studies of the photoluminescence of the fibrous tunic of the eye, excited by polarized light, depending on the intraocular pressure. In the experiments, isolated de-epithelized eyes of the rabbit were used, inside of which pressure up to 50 mm Hg was artificially created. Under these conditions, the cornea and sclera were illuminated with linearly polarized light at wavelengths of 250, 350 and 450 nm, exciting photoluminescence in the wavelength range up to 700 nm. Cross and co-polarized photoluminescence spectra excited by linearly polarized light were obtained. It has been established that, when excited by polarized light, the photoluminescence of the cornea is partially polarized. Depending on the wavelength of the photoluminescence, the degree of polarization varies from 0.2 to 0.35. It is shown that the degree of polarization of the photoluminescence of the cornea of the eye upon excitation by linearly polarized light can be used as a measurable parameter for assessing the physiological state of the eye. It is shown that the photoluminescence spectrum consists of two bands with maxima near 460-470 and 430-440 nm. These bands are assigned, respectively, to pyridinnucleotides and glycosylated collagen. A significant contribution can be made by the epithelium of the eye, which contains riboflavin with characteristic absorption bands near 450 and 365 nm. When excited at 450 nm, the photoluminescence maximum is located near 540 nm, which corresponds to the spectrum of fluorophores in the endothelium and epithelium. The spectrum of photoluminescence upon excitation at a wavelength of 250 nm can be attributed to tryptophan located in the intraocular lens.

  20. Autologous serum eye drops for dry eye

    Science.gov (United States)

    Pan, Qing; Angelina, Adla; Marrone, Michael; Stark, Walter J; Akpek, Esen K

    2017-01-01

    Background Theoretically, autologous serum eye drops (AS) offer a potential advantage over traditional therapies on the assumption that AS not only serve as a lacrimal substitute to provide lubrication but contain other biochemical components that allow them to mimic natural tears more closely. Application of AS has gained popularity as second-line therapy for patients with dry eye. Published studies on this subject indicate that autologous serum could be an effective treatment for dry eye. Objectives We conducted this review to evaluate the efficacy and safety of AS given alone or in combination with artificial tears as compared with artificial tears alone, saline, placebo, or no treatment for adults with dry eye. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 5), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to July 2016), Embase (January 1980 to July 2016), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to July 2016), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We also searched the Science Citation Index Expanded database (December 2016) and reference lists of included studies. We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 5 July 2016. Selection criteria We included randomized controlled trials (RCTs) that compared AS versus artificial tears for treatment of adults with dry eye. Data collection and analysis Two review authors independently screened all titles and abstracts and assessed full-text reports of potentially eligible trials. Two review authors extracted data and assessed risk of bias and characteristics of included

  1. Efficacy of combined pranoprofen eye drops and artificial tears on the treatment of mild to moderate dry eye syndrome after trabbeculectomy

    Directory of Open Access Journals (Sweden)

    Guang-Ming Zhao

    2015-02-01

    Full Text Available AIM:To evaluate the efficacy of combined pranoprofen eye drops and artificial tears on the treatment of mild to moderate dry eye syndrome after trabbeculectomy. METHODS: This prospective case control study included 63 cases(63 eyesof patients with mild to moderate dry eye syndrome after trabbeculectomy in our hospital from November 2013 to June 2013. All subjects were randomly divided into two groups. Observation group was treated with combined pranoprofen eye drops and artificial tears and control group received simple artificial tears marking the eyes at 1, 2, 4wk. The patient's symptoms, signs, BUT, SⅠt, and FL were observed before treatment and 1, 2, 4wk after treatment. RESULTS:After 2wk, the symptoms of observation group were improved, there was statistically significant difference(PPPPCONCLUSION: Artificial tears joint pranoprofen eye drops has good curative effect in the treatment of mild to moderate dry eye syndrome after trabbeculectomy.

  2. Twenty years on: Poverty and hardship in urban Fiji

    Directory of Open Access Journals (Sweden)

    Jenny Bryant-Tokalau

    2012-09-01

    Full Text Available Through ‘official statistics’, academic and donor interpretations as well as the eyes of Suva residents, this paper presents an overview and case study of twenty years of growing poverty and hardship in the contemporary Pacific. Focusing on the past two decades, the paper notes how much, and yet so little, has changed for those attempting to make a living in the rapidly developing towns and cities. Changing interpretations of poverty and hardship are presented, moving from the ‘no such thing’ view, to simplification, and finally to an understanding that Pacific island countries, especially Fiji, are no longer an ‘extension’ of Australia and New Zealand, but independent nations actively trying to find solutions to their issues of economic, social and political hardship whilst facing challenges to traditional institutions and networks. Fiji is in some respects a very particular case as almost half of the population has limited access to secure land, but the very nature of that vulnerability to hardship and poverty holds useful lessons for wider analysis.

  3. Evaluating two methods of digital photography in retinopathy screening

    Directory of Open Access Journals (Sweden)

    Li Chen

    2018-02-01

    Full Text Available AIM:To evaluate the advantages of non-mydriatic fundus photography(NMFCSand mydriatic fundus photography(MFCSas eye-bottom screening and diagnosis methods in compared with gold standard fluorescein fundus angiography(FFA. METHODS: A total of 276 patients which involved in Chronic Diabetes Management Achieves within 4 streets of Pudong District Shanghai, were enrolled for diabetic retinopathy(DRexamination including NMFCS, MFCS and FFA. These DR examinations were proceeded after vision, slit-lamp and dioptroscopy tests, and reported by professionals. For those with suspicious fundus diseases, we would make appointments with specialist for further treatment. RESULTS: A total of 1104 colorful fundus images, and 1056 images(95.65%could be used to analyze. There were 408 appreciable images, 116 basically appreciable images and 28 unusable images in 552 NMFCS images. In addition, there were 432 appreciable images, 100 basically appreciable images and 20 unusable images in 552 MFCS images. There was no significant differences between NMFCS and MFCS(P>0.05. Compared with FFA with DRⅠ as the critical value, the specificity of digital photography for NMFCS was 95.71%, the sensitivity was 93.56%; however, MFCS are 95.43% and 98.02%. There was no statistically significant difference between the two screening methods(P>0.05. Compared with FFA with DRⅡ as the critical value, the specificity of digital photography for NMFCS was 95.35% and the sensitivity was 93.44%; however, for MFCS were 95.81% and 98.36%. There was no statistically significant difference between the two screening methods(P>0.05. CONCLUSION: Both NMFCS and MFCS could be used for the diagnosis and screening for eye diseases. NMFCS is easier and faster for digital photography, which is suitable for mass screening. MFCS is more likely to provide detailed information about the follow-up of the disease.

  4. Greek mythology: the eye, ophthalmology, eye disease, and blindness.

    Science.gov (United States)

    Trompoukis, Constantinos; Kourkoutas, Dimitrios

    2007-06-01

    In distant eras, mythology was a form of expression used by many peoples. A study of the Greek myths reveals concealed medical knowledge, in many cases relating to the eye. An analysis was made of the ancient Greek texts for mythological references relating to an understanding of vision, visual abilities, the eye, its congenital and acquired abnormalities, blindness, and eye injuries and their treatment. The Homeric epics contain anatomical descriptions of the eyes and the orbits, and an elementary knowledge of physiology is also apparent. The concept of the visual field can be seen in the myth of Argos Panoptes. Many myths describe external eye disease ("knyzosis"), visual disorders (amaurosis), and cases of blinding that, depending on the story, are ascribed to various causes. In addition, ocular motility abnormalities, congenital anomalies (cyclopia), injuries, and special treatments, such as the "licking" method, are mentioned. The study of mythological references to the eye reveals reliable medical observations of the ancient Greeks, which are concealed within the myths.

  5. Efficacy of atropine and anisodamine eye drops for adolescent pseudomyopia

    Directory of Open Access Journals (Sweden)

    Hui-Jie Wang

    2017-03-01

    Full Text Available AIM:To investigate the effect and local influence of atropine and anisodamine eye drops on adolescent pseudomyopia. METHODS:Totally 110 cases of juvenile pseudomyopia were randomly divided into two groups, the control group was given 10g/L atropine sulfate eye gel, and the observation group was treated with 5g/L raceanisodamine eye drops. The efficacy of two methods, the changes of axial length and intraocular pressure before and after treatment, and the incidence of adverse reactions were compared. RESULTS: There was no significant difference in cure rate between the two groups(χ2=0.533, P=0.465, but the effective rate of observation group was significantly better than the control group(χ2=3.907, P=0.048. Compared with the same group before treatment, the length of the axial length of the two groups increased in different degrees,and the increase value of the observation group was significantly higher than that of the control group, the difference was statistically significant(PP>0.05. The intraocular pressure of the two groups was significantly lower than that of the same group before treatment, and the difference between the two groups after treatments was not statistically significant(P >0.05. The incidence of adverse reactions in the observation group was significantly lower than that in the control group(χ2=18.939, PCONCLUSION: Anisodamine eye drops in the treatment of juvenile pseudomyopia has obvious curative effect, its efficacy and safety are better than atropine eye gel.

  6. The Effect of Ocular Surface Regularity on Contrast Sensitivity and Straylight in Dry Eye

    OpenAIRE

    Koh, Shizuka; Maeda, Naoyuki; Ikeda, Chikako; Asonuma, Sanae; Ogawa, Mai; Hiraoka, Takahiro; Oshika, Tetsuro; Nishida, Kohji

    2017-01-01

    Purpose: To investigate the association between visual function and ocular surface regularity in dry eye.Methods: We enrolled 52 eyes of 52 dry eye patients (34 dry eyes with superficial punctate keratopathy [SPK] in the central corneal region [central SPK] and 18 dry eyes without central SPK) and 20 eyes of 20 normal control subjects. All eyes had a best-corrected distance visual acuity better than 20/20. We measured two indices of contrast sensitivity function under photopic conditions: con...

  7. Searching for Chaos Evidence in Eye Movement Signals

    Directory of Open Access Journals (Sweden)

    Katarzyna Harezlak

    2018-01-01

    Full Text Available Most naturally-occurring physical phenomena are examples of nonlinear dynamic systems, the functioning of which attracts many researchers seeking to unveil their nature. The research presented in this paper is aimed at exploring eye movement dynamic features in terms of the existence of chaotic nature. Nonlinear time series analysis methods were used for this purpose. Two time series features were studied: fractal dimension and entropy, by utilising the embedding theory. The methods were applied to the data collected during the experiment with “jumping point” stimulus. Eye movements were registered by means of the Jazz-novo eye tracker. One thousand three hundred and ninety two (1392 time series were defined, based on the horizontal velocity of eye movements registered during imposed, prolonged fixations. In order to conduct detailed analysis of the signal and identify differences contributing to the observed patterns of behaviour in time scale, fractal dimension and entropy were evaluated in various time series intervals. The influence of the noise contained in the data and the impact of the utilized filter on the obtained results were also studied. The low pass filter was used for the purpose of noise reduction with a 50 Hz cut-off frequency, estimated by means of the Fourier transform and all concerned methods were applied to time series before and after noise reduction. These studies provided some premises, which allow perceiving eye movements as observed chaotic data: characteristic of a space-time separation plot, low and non-integer time series dimension, and the time series entropy characteristic for chaotic systems.

  8. The Comparison of Four Different Methods of Perioperative Eye Protection under General Anesthesia in Prone Position

    Directory of Open Access Journals (Sweden)

    Özlem Kocatürk

    2012-04-01

    Full Text Available Aim: The purpose of this study was to compare and assess the efficacy of hypoallergen adhesive tape, antibiotic ointment, artificial tear liquid gel and ocular lubricant pomade for perioperative protection of eyes under general anesthesia in prone position. Material and Method: One hundred and eighty four patients (368 eyes undergoing general anesthesia for >90 min for spinal procedures were divided randomly into four groups. Hypoallergen adhesive tape, antibiotic ointment, artificial tear liquid gel or ocular lubricant pomade was applied into the eyes. The patients underwent complete ophthalmic examination, including corrected visual acuity measurement, basal tear production, corneal and conjunctival staining both before and after surgery. Results: Basal tear production was reduced in all groups compared to preoperative values (P0.05. There was no difference between pre and postoperative visual acuity. Discussion: All of the methods are suitable for protecting corneal injuries. But none of them is good enough to avoid temporary symptoms in postoperative period. During general anesthesia eyes need protection either by tape, gel, ointment or pomade to reduce the incidence of corneal injuries.

  9. Eye movements characteristics of Chinese dyslexic children in picture searching.

    Science.gov (United States)

    Huang, Xu; Jing, Jin; Zou, Xiao-Bing; Wang, Meng-Long; Li, Xiu-Hong; Lin, Ai-Hua

    2008-09-05

    Reading Chinese, a kind of ideogram, relies more on visual cognition. The visuospatial cognitive deficit of Chinese dyslexia is an interesting topic that has received much attention. The purpose of current research was to explore the visuopatial cognitive characteristics of Chinese dyslexic children by studying their eye movements via a picture searching test. According to the diagnostic criteria defined by ICD-10, twenty-eight dyslexic children (mean age (10.12 +/- 1.42) years) were enrolled from the Clinic of Children Behavioral Disorder in the third affiliated hospital of Sun Yat-sen University. And 28 normally reading children (mean age (10.06 +/- 1.29) years), 1:1 matched by age, sex, grade and family condition were chosen from an elementary school in Guangzhou as a control group. Four groups of pictures (cock, accident, canyon, meditate) from Picture Vocabulary Test were chosen as eye movement experiment targets. All the subjects carried out the picture searching task and their eye movement data were recorded by an Eyelink II High-Speed Eye Tracker. The duration time, average fixation duration, average saccade amplitude, fixation counts and saccade counts were compared between the two groups of children. The dyslexic children had longer total fixation duration and average fixation duration (F = 7.711, P < 0.01; F = 4.520, P < 0.05), more fixation counts and saccade counts (F = 7.498, P < 0.01; F = 11.040, P < 0.01), and a smaller average saccade amplitude (F = 29.743, P < 0.01) compared with controls. But their performance in the picture vocabulary test was the same as those of the control group. The eye movement indexes were affected by the difficulty of the pictures and words, all eye movement indexes, except saccade amplitude, had a significant difference within groups (P < 0.05). Chinese dyslexic children have abnormal eye movements in picture searching, applying slow fixations, more fixations and small and frequent saccades. Their abnormal eye movement

  10. Setting up a child eye care centre: the Mercy Eye Hospital, Abak ...

    African Journals Online (AJOL)

    Aim: To document and share our experience in setting up a Child Eye Care Centre within a rural mission eye hospital and document subsequent development of services. Method: The location of the project was Mercy Eye Hospital (MEH) Abak, Akwa Ibom State in the South South zone of Nigeria). Consent to commence ...

  11. A geometric method for computing ocular kinematics and classifying gaze events using monocular remote eye tracking in a robotic environment.

    Science.gov (United States)

    Singh, Tarkeshwar; Perry, Christopher M; Herter, Troy M

    2016-01-26

    Robotic and virtual-reality systems offer tremendous potential for improving assessment and rehabilitation of neurological disorders affecting the upper extremity. A key feature of these systems is that visual stimuli are often presented within the same workspace as the hands (i.e., peripersonal space). Integrating video-based remote eye tracking with robotic and virtual-reality systems can provide an additional tool for investigating how cognitive processes influence visuomotor learning and rehabilitation of the upper extremity. However, remote eye tracking systems typically compute ocular kinematics by assuming eye movements are made in a plane with constant depth (e.g. frontal plane). When visual stimuli are presented at variable depths (e.g. transverse plane), eye movements have a vergence component that may influence reliable detection of gaze events (fixations, smooth pursuits and saccades). To our knowledge, there are no available methods to classify gaze events in the transverse plane for monocular remote eye tracking systems. Here we present a geometrical method to compute ocular kinematics from a monocular remote eye tracking system when visual stimuli are presented in the transverse plane. We then use the obtained kinematics to compute velocity-based thresholds that allow us to accurately identify onsets and offsets of fixations, saccades and smooth pursuits. Finally, we validate our algorithm by comparing the gaze events computed by the algorithm with those obtained from the eye-tracking software and manual digitization. Within the transverse plane, our algorithm reliably differentiates saccades from fixations (static visual stimuli) and smooth pursuits from saccades and fixations when visual stimuli are dynamic. The proposed methods provide advancements for examining eye movements in robotic and virtual-reality systems. Our methods can also be used with other video-based or tablet-based systems in which eye movements are performed in a peripersonal

  12. [Firework-related eye trauma from 2005 to 2013].

    Science.gov (United States)

    Unterlauft, J D; Wiedemann, P; Meier, P

    2014-09-01

    Fireworks combusted during New Year's Eve festivities can cause different eye traumas which often need complex reconstructive surgery. It was our aim to systematically analyse these eye trauma cases which were treated at our clinic during the last eight years. Age, gender, side, trauma mechanism, treatment methods and outcome were analysed for all eye trauma cases caused by fireworks during the New Year's Eve celebrations from 2006 to 2013. For statistical analysis all trauma cases were divided into two groups of major and non-major eye trauma. The total number of patients treated was 122 (28 women, 94 men, mean age 26.2±13.0 years) with 137 traumatised eyes (77 right, 60 left). 24.6% of patients were ≤18 years of age. 76.2% were bystanders. 50 eyes from 46 patients (37.7%) suffered from major eye trauma. 26 patients (21.3%) were hospitalised. 8 eyes (5.8%) suffered from a penetrating injury or globe rupture and underwent primary reconstructive surgery. Further 16 eyes (11.7%) suffered from major eye trauma without open globe injury. In the aftermath 11 eyes (8.0%) went blind (visual acuityfireworks. However older patients suffer from major eye trauma more often. More education and prophylaxis of eye trauma caused by fireworks is desirable. Georg Thieme Verlag KG Stuttgart · New York.

  13. Binocular eye movement control and motion perception: what is being tracked?

    Science.gov (United States)

    van der Steen, Johannes; Dits, Joyce

    2012-10-19

    We investigated under what conditions humans can make independent slow phase eye movements. The ability to make independent movements of the two eyes generally is attributed to few specialized lateral eyed animal species, for example chameleons. In our study, we showed that humans also can move the eyes in different directions. To maintain binocular retinal correspondence independent slow phase movements of each eye are produced. We used the scleral search coil method to measure binocular eye movements in response to dichoptically viewed visual stimuli oscillating in orthogonal direction. Correlated stimuli led to orthogonal slow eye movements, while the binocularly perceived motion was the vector sum of the motion presented to each eye. The importance of binocular fusion on independency of the movements of the two eyes was investigated with anti-correlated stimuli. The perceived global motion pattern of anti-correlated dichoptic stimuli was perceived as an oblique oscillatory motion, as well as resulted in a conjugate oblique motion of the eyes. We propose that the ability to make independent slow phase eye movements in humans is used to maintain binocular retinal correspondence. Eye-of-origin and binocular information are used during the processing of binocular visual information, and it is decided at an early stage whether binocular or monocular motion information and independent slow phase eye movements of each eye are produced during binocular tracking.

  14. Optic Disc Change during Childhood Myopic Shift: Comparison between Eyes with an Enlarged Cup-To-Disc Ratio and Childhood Glaucoma Compared to Normal Myopic Eyes.

    Directory of Open Access Journals (Sweden)

    Hae-Young Lopilly Park

    Full Text Available Progressive disc tilting and the development or enlargement of peripapillary atrophy (PPA are observed during a myopic shift in children. This could be related to the changes around the optic nerve head during eyeball elongation. If the biomechanical properties at or around the optic nerve head are changed after exposure to elevated intraocular pressure (IOP in glaucoma eyes, different response of the disc tilting and PPA changes could take place during eyeball elongation by myopic shift. On the basis of this background, the aim of this study was to compare the morphological changes in the optic disc induced by a myopic shift during childhood between normal control eyes, eyes from disc suspects with an enlarged cup-to-disc ratio (CDR, and eyes with childhood glaucoma.Total of 82 eyes from 82 subjects younger than 14 years of age were included in the study. Serial disc photographs were classified into one of two groups: eyes with an optic nerve head (ONH or peripapillary atrophy (PPA change or without an ONH/PPA change. Using ImageJ software, the outlines of the optic disc and PPA were plotted, and the vertical disc diameter (VDD, horizontal disc diameter (HDD, and maximum PPA width (PPW were measured. The changes in the ratios of these parameters and the relationships between the degree of myopic shift or the ONH/PPA change were analyzed.Twenty-five eyes with normal optic disc appearance, 36 eyes with enlarged cup-to-disc ratio, and 21 eyes of glaucoma patients were analyzed. The initial intraocular pressure (IOP at diagnosis was significantly different among the groups (P<0.001. The degree of myopic shift during follow-up period was not significantly different among the groups (P=0.612. However, the changes in the HDD/VDD and PPW/VDD ratios were significantly greater in the disc suspect group and significantly smaller in the glaucoma group. Among the 42 eyes with an ONH/PPA change, 16 (38.1% were from the normal control group, 24 (57.1% were

  15. Preliminary Effects of Oral Uridine on the Ocular Surface in Dry Eye Patients

    OpenAIRE

    Chang, Ki Cheol; Oh, Joo Youn; In, Youn Seok; Kim, Mee Kum; Shin, Ki Cheul; Wee, Won Ryang; Lee, Jin Hak; Park, Myung Gyu

    2009-01-01

    We designed a randomized, double blinded, 3-months controlled prospective clinical study to investigate effects of oral uridine on the ocular surface in dry eye patients. Twenty-seven patients who diagnosed as dry eye with lower than 5 mm of wetting in the Schirmer strip, with corneal epithelial erosion and who completely followed-up till 3 months were enrolled. Corneal-conjunctival fluorescein staining, non-anesthetic Schirmer test, impression cytology, and Ocular Surface Disease Index (OSDI...

  16. The National Basketball Association eye injury study.

    Science.gov (United States)

    Zagelbaum, B M; Starkey, C; Hersh, P S; Donnenfeld, E D; Perry, H D; Jeffers, J B

    1995-06-01

    To investigate the epidemiology of eye injuries sustained by professional basketball players in the National Basketball Association (NBA). A prospective study involving all NBA athletes who sustained eye injuries between February 1, 1992, and June 20, 1993, was conducted. Twenty-seven NBA team athletic trainers, physicians, and ophthalmologists were provided data forms to complete for any player examined for an eye injury. Practice and game exposures during the preseason, regular season, playoffs, and championships were included. Of the 1092 injuries sustained by NBA players during the 17-month period, 59 (5.4%) involved the eye and adnexa. Eighteen (30.5%) of the injuries occurred while the player was in the act of rebounding, and 16 (27.1%) while the player was on offense. The most common diagnoses included 30 abrasions or lacerations to the eyelid (50.9%), 17 contusions (edema and/or ecchymosis) to the eyelid or periorbital region (28.8%), and seven corneal abrasions (11.9%). There were three orbital fractures (5.1%). Most injuries were caused by fingers (35.6%) or elbows (28.8%). Nine players (15.3%) missed subsequent games because of their injury. Fifty-seven players (96.6%) were not wearing protective eyewear at the time of injury. The incidence of eye injuries in NBA players during the 17-month period was 1.44 per 1000 game exposures. Frequent physical contact in professional basketball players leaves them at great risk for sustaining eye injuries. To prevent these injuries, protective eyewear is recommended.

  17. Two kinds of manual chopping methods applied in small incision extracapsular cataract extraction

    Directory of Open Access Journals (Sweden)

    Xia Jiang

    2016-02-01

    Full Text Available AIM:To research clinical effect of two manual chopping methods for small incision extracapsular cataract extraction. METHODS: We observed 143 cases(184 eyeswith grade Ⅳ or higher taken the small incision cataract extraction and intraocular lens implantation. Patients were given randomly knifed chopping with closed hook(92 eyesor double knifed chopping(92 eyes. The intra-operative posterior capsule rupture was observed and compared. At 1d, 1wk and 1mo postoperatively, visual acuity, corneal edema and corneal astigmatism were observed and analyzed. RESULTS:There were 10 eyes in patients accepting knifed chopping with closed hook with intra-operative posterior capsule rupture and 1 eye in patients accepting double knifed chopping. The difference between the two groups was statistically significant. The visual acuity of patients accepting knifed chopping with closed hook(92 eyesat 1d postoperatively was 0.380±0.105, and that of patients accepting double knifed chopping(92 eyeswas 0.420±0.095; the difference between the two groups was statistically significant. The visual acuity of patients accepting knifed chopping with closed hook(84 eyesat 1wk postoperatively was 0.480±0.123, and that of patients accepting double knifed chopping(86 eyeswas 0.520±0.085; the difference between the two groups was statistically significant. The visual acuity of patients accepting knifed chopping with closed hook(60 eyesat 1mo postoperatively was 0.610±0.083, and that of patients accepting double knifed chopping(52 eyeswas 0.643±0.072; the difference between the two groups was not statistically significant. The differences on corneal edema and corneal astigmatism between the two methods at 1d, 1wk and 1mo postoperatively were not statistically significant. CONCLUSION:The application of knifed chopping with closed hook and double knifed chopping in small incision extracapsular cataract extraction and intraocular lens implantation can effectively treat with

  18. A comparison of two approaches to managing acute primary angle closure in Asian eyes

    Directory of Open Access Journals (Sweden)

    Ho H

    2013-06-01

    Full Text Available Henrietta Ho,1 Paul T Chew,2 Chelvin Sng,1,2 Huiqi Huang,1 Tin Aung,1,2 Shamira A Perera1,21Singapore Eye Research Institute, Singapore National Eye Centre, Singapore; 2Yong Loo Lin School of Medicine, National University of Singapore and National University Health System, SingaporePurpose: To review the management regimes of acute primary angle closure (APAC in two hospitals in Singapore, and to identify the incidence of and risk factors for progression to glaucomatous optic neuropathy.Methods: We conducted a retrospective review of 40 patients from National University Hospital (NUH and 52 patients from Singapore National Eye Centre (SNEC who were diagnosed with APAC. Patients were treated with similar protocols of intensive medical therapy until laser peripheral iridotomy could be performed. In the event of failed medical treatment, patients at NUH only underwent laser iridoplasty. The 1-year outcomes were reviewed.Results: The demographic features of patients and presenting intraocular pressures (IOP were similar in both centers. More patients from NUH presented within 3 days of symptom onset, compared to those from SNEC (90.0% versus 71.2%, respectively (P = 0.037. The mean ± standard deviation time to break the attack was 18.2 ± 32.9 hours at SNEC and 9.80 ± 10.6 hours at NUH (P = 0.11. The mean follow up duration was 18.8 ± 14.0 months. Nineteen patients (36.5% from SNEC and six patients (22.5% from NUH developed raised IOP (P = 0.032 within 1-year of the attack. Of these, glaucomatous optic neuropathy developed in thirteen patients (68.4% from SNEC and all six patients (100% from NUH. At final review, the mean IOP of the APAC eye was 14.8 ± 4.3 mmHg from SNEC and 13.4 ± 3.0 mmHg from NUH. There was no significant difference in final visual acuity or IOP between both groups.Conclusion: Treatment strategies in both centers were effective in aborting an APAC attack. The development of raised IOP appears to be associated with a longer

  19. Eye blink frequency during different computer tasks quantified by electrooculography

    DEFF Research Database (Denmark)

    Skotte, J H; Nøjgaard, J K; Jørgensen, L V

    2007-01-01

    The purpose of the study was to evaluate electrooculography (EOG) as an automatic method to measure the human eye blink frequency (BF) during passive and interactive computer tasks performed at two screen heights. Ten healthy subjects (5 males and 5 females) participated in the study in a 23...... degrees C temperature and 30-35% relative humidity controlled simulated office environment. Each test subject completed a 2 x 10 min active task of computer work and a 3 x 10 min passive task of watching a film on a video display unit (VDU). Both tasks included two viewing angles: standard (the monitors...... counted manually from the video recordings and compared to the EOG measurements. The method showed a high validity to detect blinks during computer work: 95.4% of the blinks were retrieved by the EOG method and very few artefacts from eye movements were erroneously classified as eye blinks (2.4%). By use...

  20. Eye and orbital cavity

    International Nuclear Information System (INIS)

    Panfilova, G.V.; Koval', G.Yu.

    1984-01-01

    Radioanatomy of eyes and orbit is described. Diseases of the orbit (developmental anomalies, inflammatory diseases, lacrimal apparatus deseases, toxoplasmosis, tumors and cysts et al.), methods of foreign body localization in the eye are considered. Roentgenograms of the orbit and calculation table for foreign body localization in spherical eyes of dissimilar diameter are presented

  1. Design, Sensing and Control of a Robotic Prosthetic Eye for Natural Eye Movement

    OpenAIRE

    J. J. Gu; M. Meng; A. Cook; P. X. Liu

    2006-01-01

    Loss of an eye is a tragedy for a person, who may suffer psychologically and physically. This paper is concerned with the design, sensing and control of a robotic prosthetic eye that moves horizontally in synchronization with the movement of the natural eye. Two generations of robotic prosthetic eye models have been developed. The first generation model uses an external infrared sensor array mounted on the frame of a pair of eyeglasses to detect the natural eye movement and to feed the contro...

  2. EVALUATION OF DRY EYES IN DIABETES MELLITUS

    Directory of Open Access Journals (Sweden)

    Anshu Sharma

    2017-12-01

    Full Text Available BACKGROUND According to the National Eye Institute, dry eye is a condition in which the eye does not produce tears properly. It can also involve tears not having the right consistency or evaporating too quickly. Tears are necessary to help maintain moisture on the surface of the eye and for clear vision. Diabetes is often associated with several significant ocular conditions such as retinopathy, refractive changes, cataracts, glaucoma and macular oedema. However, one of the most common ocular complications associated with diabetes is dry eye. The aim of the study is to study the prevalence of dry eyes in diabetes mellitus and to evaluate ocular and other risk factors relevant to diabetic dry eyes. MATERIALS AND METHODS A hospital-based cross-sectional clinical study of 100 diabetic patients who presented to the Department of Ophthalmology, Santosh Medical College and Hospital, Ghaziabad, between January 2016 to June 2017 was conducted. Detailed diabetic history was recorded. Assessment of anterior segment via slit-lamp biomicroscopy was done. The examinations for dry eyes included Schirmer's test, tear breakup time, fluorescein and rose Bengal staining. RESULTS Sixty two (62% diabetic patients had dry eye. The prevalence in type I was 3% and prevalence in type II was 59%. Dry eye prevalence was maximum in those above 40 years of age. Symptoms like reduced corneal sensation (44% and meibomitis (20% were major attributable risk factors. Ocular surface damage was predominantly superficial punctate keratitis. Retinopathy was not statistically associated with the prevalence of dry eyes. CONCLUSION Diabetes and dry eye appears to be a common association. Reduction in the modifiable risk factors of dry eye is essential to reduce its prevalence. No significant statistical correlation was found between retinopathy and dry eyes. However, examination for dry eyes should be an integral part of the assessment of diabetic eye disease.

  3. Stability of epitheliotrophic factors in autologous serum eye drops from chronic Stevens-Johnson syndrome dry eye compared to non-autoimmune dry eye.

    Science.gov (United States)

    Phasukkijwatana, Nopasak; Lertrit, Patcharee; Liammongkolkul, Sompong; Prabhasawat, Pinnita

    2011-09-01

    To compare the concentrations of epitheliotrophic factors in autologous serum eye drops (ASE) prepared from sera of chronic Stevens-Johnson syndrome (SJS) patients with dry eyes to those prepared from non-autoimmune dry eye controls and to study the stability of the epitheliotrophic factors in different storage conditions. Twenty-percent ASE were prepared from 10 chronic SJS patients with dry eyes and 10 age-matched non-autoimmune dry eye controls. The concentrations of major epitheliotrophic factors comprising epidermal growth factor (EGF), transforming growth factor-beta1 (TGF-β1), transforming growth factor-beta2 (TGF-β2), and fibronectin in those ASE preparations were determined by enzyme-linked immunosorbent assay (ELISA) at baseline and after different storage conditions: at 4 °C for 1 week and 1 month; and at -20 °C for 1, 3 and 6 months. There were no significant differences in the concentrations of EGF, TGF-β1, TGF-β2 and fibronectin in 20% ASE between the SJS and control groups (EGF: 176.9 ± 40.9 vs. 185.5 ± 36.9 pg/mL, TGF-β1: 9.5 ± 2.1 vs. 9.5 ± 1.9 ng/mL, TGF-β2: 55.3 ± 30.0 vs. 63.91 ± 45.6 pg/mL and fibronectin: 70.5 ± 20.2 vs. 62.2 ± 21.3 µg/mL, respectively). These factors were stable at 4 °C for up to 1 month. Storage at -20 °C for up to 6 months resulted in a slight decrease in TGF-β1 (SJS: from 9.5-8.4 ng/mL, p dry eye patients, and that ASE should be sufficiently stable for up to 6 months, if stored properly at -20 °C.

  4. Screening method for the detection of a range of nitrofurans in avian eyes by optical biosensor

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, Colin S., E-mail: colin.thompson@afbini.gov.uk [Agri-Food and Biosciences Institute, Veterinary Sciences Division, Stormont, Belfast BT4 3SD, Northern Ireland (United Kingdom); Traynor, Imelda M.; Fodey, Terence L.; Crooks, Steven R.H.; Kennedy, D. Glenn [Agri-Food and Biosciences Institute, Veterinary Sciences Division, Stormont, Belfast BT4 3SD, Northern Ireland (United Kingdom)

    2011-08-26

    An immunobiosensor assay was developed for the multi-residue screening of a range of nitrofuran compounds in avian eyes. A polyclonal antibody which binds at least 5 of the major parent nitrofurans was raised in a rabbit after inoculation with a nitrofuran mimic-protein conjugate. Sample homogenates were extracted into 0.1 M hydrochloric acid and subjected to clean-up by solid phase extraction and micro-centrifugation prior to biosensor analysis. Validation data obtained from the analysis of 21 fortified samples has shown that the method has a detection capability (CC{beta}) of less than 1 ng eye{sup -1} for nitrofurazone (NFZ). In addition, cross-reactivity data and the analysis of a smaller number of fortified samples have shown that the method will also detect a range of other major parent nitrofurans including furazolidone (FZD), furaltadone (FTD), nitrofurantoin (NFA) and nifursol (NFS). Intra-assay variation (n = 10) was calculated at 12.9% and 10.1% at concentrations of 1 ng eye{sup -1} and 2 ng eye{sup -1} NFZ respectively. Inter-assay variation (n = 3) was determined to be 10.8% and 4.7% at the same NFZ concentrations respectively. The cross-reactivity profile and validation data for the detection of these nitrofurans are presented together with the results obtained following the analysis of a small number of incurred samples using the developed method.

  5. Comparison of eye morphology and retinal topography in two species of New World vultures (Aves: Cathartidae).

    Science.gov (United States)

    Lisney, Thomas J; Stecyk, Karyn; Kolominsky, Jeffrey; Graves, Gary R; Wylie, Douglas R; Iwaniuk, Andrew N

    2013-12-01

    Vultures are highly reliant on their sensory systems for the rapid detection and localization of carrion before other scavengers can exploit the resource. In this study, we compared eye morphology and retinal topography in two species of New World vultures (Cathartidae), turkey vultures (Cathartes aura), with a highly developed olfactory sense, and black vultures (Coragyps atratus), with a less developed sense of olfaction. We found that eye size relative to body mass was the same in both species, but that black vultures have larger corneas relative to eye size than turkey vultures. However, the overall retinal topography, the total number of cells in the retinal ganglion cell layer, peak and average cell densities, cell soma area frequency distributions, and the theoretical peak anatomical spatial resolving power were the same in both species. This suggests that the visual systems of these two species are similar and that vision plays an equally important role in the biology of both species, despite the apparently greater reliance on olfaction for finding carrion in turkey vultures. Copyright © 2013 Wiley Periodicals, Inc.

  6. Pseudoexfoliation Glaucoma in the National Eye Center, Cicendo Eye Hospital, January–October 2012

    Directory of Open Access Journals (Sweden)

    Rizki Fasa Ramdhani

    2015-03-01

    Full Text Available Background: Pseudoexfoliation syndrome is characterized by the deposition of a distinctive fibrillar material in the anterior segment of the eye. This condition is a major risk factor for development of glaucoma, termed pseudoexfoliation glaucoma (PEXG. The aim of this study was to describe the characteristic and management of PEXG in the National Eye Center Cicendo Eye Hospital. Methods: A descriptive retrospective study was conducted in October–November 2012 using medical records of PEXG patients in the National Eye Center Cicendo Eye Hospital during January–October 2012. Results: There were 32 patients (43 eyes diagnosed as PEXG, most of them were male (78.1%, age 70–74 years old (34.4% and followed by those in the range of age 65–69 years old (21.9%. Most of the cases were unilateral (65.6% decrease of visual acuity less than 3/60 (76.7%, increase of intraocular pressure (IOP with majority in the range of 31–40 mmHg (32.6% and 41–50 mmHg (32.6%, Cup/Disc Ratio 0.9–1.0 (46.51% and followed by those classified as majority which were hard to assess because of the presence of opaque media (34.89%. The type of glaucoma was open angle glaucoma (88.4%. The treatment received was a combination of two types of antiglaucoma medication and surgery IOP Conclusion: PEXG is mostly found in elderly patients. While most of the patients come with high IOP and late stage of the disease IOP

  7. Comparison of postoperative corneal changes between dry eye and non-dry eye in a murine cataract surgery model

    Science.gov (United States)

    Kwon, Jin Woo; Chung, Yeon Woong; Choi, Jin A; La, Tae Yoon; Jee, Dong Hyun; Cho, Yang Kyung

    2016-01-01

    AIM To compare the effects of the surgical insult of cataract surgery on corneal inflammatory infiltration, neovascularization (NV) and lymphangiogenesis (LY) between the dry eye and non-dry eye in murine cataract surgery models. METHODS We established two groups of animals, one with normal eyes (non-dry eye) and the second with induced dry eyes. In both groups, we used surgical insults to mimic human cataract surgery, which consisted of lens extraction, corneal incision and suture. After harvesting of corneas on the 9th postoperative day and immunohistochemical staining, we compared NV, LY and CD11b+ cell infiltration in the corneas. RESULTS Dry eye group had significantly more inflammatory infiltration (21.75%±7.17% vs 3.65%±1.49%; P=0.049). The dry eye group showed significantly more NV (48.21%±4.02% vs 26.24%±6.01%; P=0.016) and greater levels of LY (9.27%±0.48% vs 4.84%±1.15%; P=0.007). In corneas on which no surgery was performed, there was no induction of NV in both the dry and non-dry group, but dry eye group demonstrated more CD11b+ cells infiltration than the non-dry eye group (0.360%±0.160% vs 0.023%±0.006%; P=0.068). Dry eye group showed more NV than non-dry eye group in both topical PBS application and subconjunctival PBS injection (P=0.020 and 0.000, respectively). CONCLUSION In a murine cataract surgery model, preexisting dry eye can induce more postoperative NV, LY, and inflammation in corneal tissue. PMID:26949638

  8. Line-feature-based calibration method of structured light plane parameters for robot hand-eye system

    Science.gov (United States)

    Qi, Yuhan; Jing, Fengshui; Tan, Min

    2013-03-01

    For monocular-structured light vision measurement, it is essential to calibrate the structured light plane parameters in addition to the camera intrinsic parameters. A line-feature-based calibration method of structured light plane parameters for a robot hand-eye system is proposed. Structured light stripes are selected as calibrating primitive elements, and the robot moves from one calibrating position to another with constraint in order that two misaligned stripe lines are generated. The images of stripe lines could then be captured by the camera fixed at the robot's end link. During calibration, the equations of two stripe lines in the camera coordinate system are calculated, and then the structured light plane could be determined. As the robot's motion may affect the effectiveness of calibration, so the robot's motion constraints are analyzed. A calibration experiment and two vision measurement experiments are implemented, and the results reveal that the calibration accuracy can meet the precision requirement of robot thick plate welding. Finally, analysis and discussion are provided to illustrate that the method has a high efficiency fit for industrial in-situ calibration.

  9. Application of 3-Dimensional Printing Technology to Construct an Eye Model for Fundus Viewing Study

    OpenAIRE

    Xie, Ping; Hu, Zizhong; Zhang, Xiaojun; Li, Xinhua; Gao, Zhishan; Yuan, Dongqing; Liu, Qinghuai

    2014-01-01

    Objective To construct a life-sized eye model using the three-dimensional (3D) printing technology for fundus viewing study of the viewing system. Methods We devised our schematic model eye based on Navarro's eye and redesigned some parameters because of the change of the corneal material and the implantation of intraocular lenses (IOLs). Optical performance of our schematic model eye was compared with Navarro's schematic eye and other two reported physical model eyes using the ZEMAX optical ...

  10. Effects of eye drops of Buddleja officinalis Maxim. extract on lacrimal gland cell apoptosis in castrated rats with dry eye.

    Science.gov (United States)

    Peng, Qing-hua; Yao, Xiao-lei; Wu, Quan-long; Tan, Han-yu; Zhang, Jing-rong

    2010-03-01

    To explore the possible mechanism of eye drops of Buddleja officinalis extract in treating dry eye of castrated rats by analyzing the expressions of Bax and Bcl-2 proteins. Forty-five Wistar male rats were randomly divided into sham-operated group, untreated group and eye drops of Buddleja officinalis Maxim. extract (treatment) group. The dry eye model was established with orchiectomy in the untreated group and treatment group. Rats in the treatment group were treated with eye drops of Buddleja officinalis Maxim. extract, one drop once, three times daily. Eyes of rats in the sham-operated group and untreated group were instilled with normal saline. After one-, two-, or three-month treatment, five rats in each group were scarified respectively. Then samples were taken to detect related indices. Expressions of Bax and Bcl-2 of lacrimal gland were checked by immunohistochemical method and quantity of apoptotic cells was counted. After one-, two- or three-month treatment, the quantities of expressions of Bax in acinar epithelial cells and glandular tube cells were significantly lower, and those of Bcl-2 were significantly higher in the treatment group than in the untreated group, and the quantities of apoptotic cells of the treatment group were significantly lower than those of the untreated group (PBuddleja officinalis Maxim. are flavonoids, which can significantly inhibit cell apoptosis in lacrimal gland.

  11. Vitrigel-eye irritancy test method using HCE-T cells.

    Science.gov (United States)

    Yamaguchi, Hiroyuki; Kojima, Hajime; Takezawa, Toshiaki

    2013-10-01

    We previously reported that the time-dependent relative changes of transepithelial electrical resistance (TEER) after exposing four different chemicals to a human corneal epithelium (HCE) model were well correlated to the potential of ocular irritancy. Meanwhile, we recently developed a collagen vitrigel membrane (CVM) chamber possessing a scaffold composed of high-density collagen fibrils equivalent to connective tissues in vivo as a three-dimensional culture tool. The CVM chamber is useful for biomedical assays and immunohistology using cryosections that are inappropriate to be performed using the conventional Millicell chamber with a polyethylene terephthalate membrane. In this study, we aimed to develop a new eye irritancy test (EIT) method called "Vitrigel-EIT method" that can facilitate to briefly and accurately estimate the widespread irritancy of test chemicals by applying the TEER assay system to a HCE model fabricated in the CVM chamber. HCE-T cells (a HCE-derived cell strain) were cultured in the CVM chamber for 6 days, and consequently, the Vitrigel-HCE model possessing the following characteristics of HCE in vivo was formed: six cell layers with specific protein expressions and their barrier function. Time-dependent profiles of TEER values after exposing 30 test chemicals to the HCE model were converted into the scores of three indexes (time lag, intensity, and plateau level), and each chemical was successfully classified into irritant or nonirritant category by utilizing the criteria for the indexes, resulting in the excellent correlation with Globally Harmonized System of Classification and Labelling of Chemicals (GHS) classification (sensitivity: 100%, specificity: 75%, accuracy: 90%). These data suggest that the widespread eye irritancy of chemicals can be predicted without false negatives by the Vitrigel-EIT method. Interestingly, the disruption of tight junctions was immunohistologically observed after exposing not only irritants but also three

  12. In vitro eye corrosion study of agrochemicals on isolated chicken eye.

    Science.gov (United States)

    Buda, I; Budai, P; Szabó, R; Lehel, J

    2013-01-01

    Agrochemicals must undergo numberless toxicological tests before marketing. The eye irritation test is part of this test packet. Nowadays, OECD 405 can be used to classify the irritation potential of substances, the base of the OECD 405 guideline is the Draize test, which is one of the most criticized in vivo methods because of the injuries of the test animals and subjective nature of the test in recording the results. Therefore, several in vitro tests have been developed to replace totally or partly the in vivo eye irritation testing. The isolated chicken eye test method (OECD 438), which was used, is one of these alternative methods. Five different agrochemicals were examined in the following way: All test compounds were applied in a single dose onto the cornea of isolated chicken eyes in order to potentially classify the test compounds as ocular corrosive and/or severe irritant. The damages caused by the test substances were assessed by the determination of corneal swelling, opacity, fluorescein retention and morphological effects. These parameters were evaluated pre-treatment and starting at approximately 30, 75, 120, 180, and 240 minutes after the post-treatment rinse. The endpoints evaluated were corneal opacity, swelling, fluorescein retention and morphological effects. All of the endpoints, with the exception of fluorescein retention (which was determined only at pre-treatment and 30 minutes after test substance exposure) were determined at each of the above time points. Positive and negative controls were used and they showed the expected results in each study. In these in vitro eye corrosives and severe irritants studies, using the Isolated Chicken Eye model with five different products, no ocular corrosion or severe irritation potential were observed. These results correspond to the available information about the tested agrochemicals, so these studies with isolated chicken eye are considered to be successful.

  13. A GENERALIZED NON-LINEAR METHOD FOR DISTORTION CORRECTION AND TOP-DOWN VIEW CONVERSION OF FISH EYE IMAGES

    Directory of Open Access Journals (Sweden)

    Vivek Singh Bawa

    2017-06-01

    Full Text Available Advanced driver assistance systems (ADAS have been developed to automate and modify vehicles for safety and better driving experience. Among all computer vision modules in ADAS, 360-degree surround view generation of immediate surroundings of the vehicle is very important, due to application in on-road traffic assistance, parking assistance etc. This paper presents a novel algorithm for fast and computationally efficient transformation of input fisheye images into required top down view. This paper also presents a generalized framework for generating top down view of images captured by cameras with fish-eye lenses mounted on vehicles, irrespective of pitch or tilt angle. The proposed approach comprises of two major steps, viz. correcting the fish-eye lens images to rectilinear images, and generating top-view perspective of the corrected images. The images captured by the fish-eye lens possess barrel distortion, for which a nonlinear and non-iterative method is used. Thereafter, homography is used to obtain top-down view of corrected images. This paper also targets to develop surroundings of the vehicle for wider distortion less field of view and camera perspective independent top down view, with minimum computation cost which is essential due to limited computation power on vehicles.

  14. A randomized clinical evaluation of the safety of Systane® Lubricant Eye Drops for the relief of dry eye symptoms following LASIK refractive surgery

    Directory of Open Access Journals (Sweden)

    Daniel Durrie

    2008-12-01

    Full Text Available Daniel Durrie, Jason StahlDurrie Vision, Overland Park, Kansas, USAPurpose: To evaluate the safety of Systane® Lubricant Eye Drops in relieving the symptoms of dry eye following laser-assisted in situ keratomileusis (LASIK surgery.Methods: This was a randomized, double-masked, single-center, placebo-controlled, contralateral eye study of 30 patients undergoing LASIK surgery. The mean age of patients was 42.4 ± 10.7 years, and the mean spherical equivalent was −3.29 (range, +1.75 to −7.38. Patients’ right and left eyes were randomized to receive either Systane® or placebo – a preserved, thimerosal-free saline solution – beginning from the day of surgery and ending 30 days following surgery. Outcome measures included tear film break up time (TFBUT, visual acuity, degree of corneal and conjunctival staining, and treatment-related adverse events.Results: Preoperatively, placebo-treated eyes had statistically significantly higher sum corneal staining score than Systane®-treated eyes (p = 0.0464; however, the difference was clinically insignificant (p = 0.27. Two weeks post operatively, the average TFBUT in the Systane®-treated eyes was 1.23 seconds longer than that of the placebo-treated eyes (p = 0.028. All other evaluated variables were comparable between the two treatments. No adverse events were reported in the study.Conclusion: Systane® Lubricant Eye Drops are safe for use following LASIK surgery to relieve the discomfort symptoms of dry eye associated with the procedure.Keywords: Systane®, safety, dry eye, LASIK

  15. Preliminary effects of oral uridine on the ocular surface in dry eye patients.

    Science.gov (United States)

    Chang, Ki Cheol; Oh, Joo Youn; In, Youn Seok; Kim, Mee Kum; Shin, Ki Cheul; Wee, Won Ryang; Lee, Jin Hak; Park, Myung Gyu

    2009-08-01

    We designed a randomized, double blinded, 3-months controlled prospective clinical study to investigate effects of oral uridine on the ocular surface in dry eye patients. Twenty-seven patients who diagnosed as dry eye with lower than 5 mm of wetting in the Schirmer strip, with corneal epithelial erosion and who completely followed-up till 3 months were enrolled. Corneal-conjunctival fluorescein staining, non-anesthetic Schirmer test, impression cytology, and Ocular Surface Disease Index (OSDI) were evaluated in the experimental and placebo groups at the baseline, 1 and 3 months after start of medication in a double blinded manner. Fluorescein stain score of the cornea was markedly decreased in oral uridine group compared to the placebo group at 3 months after medication (P=0.032, Mann-Whitney U test). The Schirmer wetting score for the oral uridine group was significantly increased (P=0.001, Wilcoxon signed rank test) at 3 months and its difference between two groups was statistically significant (P=0.030, Mann-Whitney U test). OSDI scores were significantly decreased at 1 and 3 months in treatment group. Oral uridine is effective in treatment of dry eyes.

  16. The Comparison of Four Different Methods of Perioperative Eye Protection under General Anesthesia in Prone Position

    OpenAIRE

    Özlem Kocatürk; Tolga Kocatürk; Nil Kaan; Volkan Dayanır

    2012-01-01

    Aim: The purpose of this study was to compare and assess the efficacy of hypoallergen adhesive tape, antibiotic ointment, artificial tear liquid gel and ocular lubricant pomade for perioperative protection of eyes under general anesthesia in prone position. Material and Method: One hundred and eighty four patients (368 eyes) undergoing general anesthesia for >90 min for spinal procedures were divided randomly into four groups. Hypoallergen adhesive tape, antibiotic ointment, artificial tea...

  17. Clinical observation of Qiming granule combined with Dextran and Hypromellose eye drops for dry eye

    OpenAIRE

    Jin-Lan Wan; Ming-Chang Zhang

    2013-01-01

    AIM: To observe the efficacy of Qiming granule combined with Dextran and Hypromellose eye drops in treatment of dry eye.METHODS: A randomized, parallel-control approach was adopted, 100 cases of dry eye patients were divided into treatment group and control group equally, observation on the treatment of 3 months. The treatment group was applied Dextran and Hypromellose eye drops combined with oral Qiming granule, simply Dextran and Hypromellose eye drops for control group. Before and after tr...

  18. Tracking the Mind's Eye: A New Technology for Researching Twenty-First-Century Writing and Reading Processes

    Science.gov (United States)

    Anson, Chris M.; Schwegler, Robert A.

    2012-01-01

    This article describes the nature of eye-tracking technology and its use in the study of discourse processes, particularly reading. It then suggests several areas of research in composition studies, especially at the intersection of writing, reading, and digital media, that can benefit from the use of this technology. (Contains 2 figures.)

  19. Daytime Variations of Tear Osmolarity Measurement in Dry Eye Patients

    Directory of Open Access Journals (Sweden)

    Ulviye Yiğit

    2013-12-01

    Full Text Available Purpose: We have targeted primarily to show the variations of tear osmolarity during the daytime period in subjects with dry eyes and non-dry eyes and, secondarily, to evaluate the relationship of these variations with Schirmer’s test and break-up time (BUT. Material and Method: Twenty newly diagnosed dry eye patients and 20 healthy voluntary subjects with similar age and gender were included in this prospective study. In addition to the full ophthalmic examination, Schirmer’s test and BUT test were applied to all participants. Tear osmolarity measurements were done after pre-examination but in different day. The measurements were registered with TearLab Osmolarity System (TearLab Corporation, San Diego, CA, USA every 3 hours within 8:00 AM and 5:00 PM. The results were evaluated statistically. Results: No statistically significant difference was found between the mean age and gender of dry eye syndrome (DES and control groups (p>0.05. The mean measurements of Schirmer’s test and BUT in the DES group were statistically significantly lower than those in the control group (p=0.0001. The mean measurements of tear osmolarity at 8:00 AM, 11:00 AM, 2:00 PM, and 5:00 PM in the DES group were statistically significantly higher than those in the control group (p=0.001, p=0.0001. No statistically significant difference in tear osmolarity at 8:00 AM, 11: 00 AM, 2:00 PM, and 5:00 PM was found between the groups, and within DES and control groups (p>0.05. Discussion: We did not determine significant change in daytime variations of the tear osmolarity in dry eye patients and healthy subjects. As a secondary result, we can conclude that there is no difference among tear osmolarity, Shirmer’s and BUT tests in the diagnosis of DES. (Turk J Ophthalmol 2013; 43: 437-41

  20. A Scoping Review of the Associations of Golf with Eye Injuries in Adults and Children

    Science.gov (United States)

    2016-01-01

    Introduction. Sport presents a risk of ocular trauma and accounts for a significant number of eye injuries that require hospital admission. The sport of golf presents a risk to eyesight from fast moving objects such as golf clubs and balls. This study aims to investigate the associations of golf with eye injuries and the reasons that these injuries occur. Material/Methods. A literature search was conducted using the databases MEDLINE, Web of Science, SPORTDiscus, and PsycINFO. Grey literature was searched using the WHO international clinical trials registry platform, Google Scholar, and ProQuest. Data was extracted using a standardised form and summarised into a report. Results and Discussion. Twenty-three studies were found relating to eye injuries in golf. Injuries appear to be rare, but more frequent in men and children. Injuries resulted in high rates of enucleation and visual impairment. Children sustained more injury from golf clubs whereas adults sustained more injuries from golf balls. Conclusion. Efforts are needed to encourage golf participants to understand the risks of ocular and indeed other head injuries. Initiatives to provide appropriate supervision and education on this topic are merited. Further research is needed to investigate the circumstances of eye injury in golf and assess the effects of interventions aimed at reducing risk of injury. PMID:27504485

  1. The study of myocardial ischemic quality with weighted-subtraction-bull's-eye analysis

    International Nuclear Information System (INIS)

    Chen Wuduan; Tian Jiahe; Hou Qingtian

    1993-01-01

    Weighted-Subtraction-Bull's-eye analysis was studied in 33 normal subjects and 58 patients with coronary artery disease after dipyridamole 99m Tc-MIBI myocardial SPECT imaging. Two kinds of Bull's-eye were produced: (1) subtract rest from 1.2 times dipyridamole from 1.2 times rest Bull's-eye; (2) subtract dipyridamole Bull's-eye. The results showed that the weighted-subtraction-Bull's-eye could clearly displayed the location and puality of ischemic myocardium. And also 74% segments showed so called combined ischemic i.e the blood perfusion reduced, increased and sustained simultaneously after dipyridamole. Therefore weighted-subtraction-Bull's-eye analysis had provided a new method for determination of the quality of ischemia

  2. Comparative Study of Anterior Eye Segment Measurements with Spectral Swept-Source and Time-Domain Optical Coherence Tomography in Eyes with Corneal Dystrophies

    Directory of Open Access Journals (Sweden)

    Anna K. Nowinska

    2015-01-01

    Full Text Available Purpose. To compare anterior eye segment measurements and morphology obtained with two optical coherence tomography systems (TD OCT, SS OCT in eyes with corneal dystrophies (CDs. Methods. Fifty healthy volunteers (50 eyes and 54 patients (96 eyes diagnosed with CD (epithelial basement membrane dystrophy, EBMD = 12 eyes; Thiel-Behnke CD = 6 eyes; lattice CD TGFBI type = 15 eyes; granular CD type 1 = 7 eyes, granular CD type 2 = 2 eyes; macular CD = 23 eyes; and Fuchs endothelial CD = 31 eyes were recruited for the study. Automated and manual central corneal thickness (aCCT, mCCT, anterior chamber depth (ACD, and nasal and temporal trabecular iris angle (nTIA, tTIA were measured and compared with Bland-Altman plots. Results. Good agreement between the TD and SS OCT measurements was demonstrated for mCCT and aCCT in normal individuals and for mCCT in the CDs group. The ACD, nTIA, and tTIA measurements differed significantly in both groups. TBCD, LCD, and FECD caused increased CCT. MCD caused significant corneal thinning. FECD affected all analyzed parameters. Conclusions. Better agreement between SS OCT and TD OCT measurements was demonstrated in normal individuals compared to the CDs group. OCT provides comprehensive corneal deposits analysis and demonstrates the association of CD with CCT, ACD, and TIA measurements.

  3. Reading strategies in mild to moderate strabismic amblyopia: an eye movement investigation.

    Science.gov (United States)

    Kanonidou, Evgenia; Proudlock, Frank A; Gottlob, Irene

    2010-07-01

    PURPOSE. To investigate oculomotor strategies in strabismic amblyopia and evaluate abnormalities during monocular and binocular reading. METHODS. Eye movements were recorded with a head-mounted infrared video eye-tracker (250 Hz, amblyopia, reading is impaired, not only during monocular viewing with the amblyopic eye, but also with the nonamblyopic eye and binocularly, even though normal visual acuity pertains to the latter two conditions. The impaired reading performance is associated with differences in both the saccadic and fixational patterns, most likely as adaptation strategies to abnormal sensory experiences such as crowding and suppression.

  4. Effect of rb-bFGF eye drops and hydroxyl indican eye drops on tear film stability and dry eye symptoms after age-related cataract surgery

    Directory of Open Access Journals (Sweden)

    Jing Chen

    2017-10-01

    Full Text Available AIM: To compare and analyze the effect of recombinant bovine basic fibroblast growth factor(bFGFeye drops and hydroxyl indican eye drops on the tear film stability and dry eye symptoms after age-related cataract surgery. METHODS: A total of 115 patients(115 affected eyeswith dry eyes after age-related cataract surgery were divided into the bFGF group, the hydroxyl indican group and the blank control group by the random number table method. The blank control group was only given routine anti-inflammatory treatment, and on the basis, the bFGF group and the hydroxyl indican group were treated with bFGF eye drops and hydroxyl indican eye drops respectively. The clinical efficacy, adverse reactions, changes in scores of dry eye symptoms, Schirmer test(SⅠt, tear film break-up time(BUTand corneal fluorescein staining(CFSscores at different time points were compared among the three groups. RESULTS: The total markedly effective rates in the bFGF group(89.5%was higher than that in the hydroxyl indican group(70.3%or the blank control group(47.5%(PPPCONCLUSION: The tear film is unstable in early stage after age-related cataract surgery, and there are dry eye symptoms. The intervention with bFGF eye drops and hydroxyl indican eye drops can effectively restore the tear film stability and significantly relieve dry eye symptoms, and the effect of bFGF eye drops is more significant.

  5. Parent Perception of Two Eye-Gaze Control Technology Systems in Young Children with Cerebral Palsy: Pilot Study.

    Science.gov (United States)

    Karlsson, Petra; Wallen, Margaret

    2017-01-01

    Eye-gaze control technology enables people with significant physical disability to access computers for communication, play, learning and environmental control. This pilot study used a multiple case study design with repeated baseline assessment and parents' evaluations to compare two eye-gaze control technology systems to identify any differences in factors such as ease of use and impact of the systems for their young children. Five children, aged 3 to 5 years, with dyskinetic cerebral palsy, and their families participated. Overall, families were satisfied with both the Tobii PCEye Go and myGaze® eye tracker, found them easy to position and use, and children learned to operate them quickly. This technology provides young children with important opportunities for learning, play, leisure, and developing communication.

  6. The "hypnotic state" and eye movements : Less there than meets the eye?

    NARCIS (Netherlands)

    Cardea, Etzel; Nordhjem, Barbara; Marcusson-Clavertz, David; Holmqvist, Kenneth

    2017-01-01

    Responsiveness to hypnotic procedures has been related to unusual eye behaviors for centuries. Kallio and collaborators claimed recently that they had found a reliable index for "the hypnotic state" through eye-tracking methods. Whether or not hypnotic responding involves a special state of

  7. An exploratory study on the driving method of speech synthesis based on the human eye reading imaging data

    Science.gov (United States)

    Gao, Pei-pei; Liu, Feng

    2016-10-01

    With the development of information technology and artificial intelligence, speech synthesis plays a significant role in the fields of Human-Computer Interaction Techniques. However, the main problem of current speech synthesis techniques is lacking of naturalness and expressiveness so that it is not yet close to the standard of natural language. Another problem is that the human-computer interaction based on the speech synthesis is too monotonous to realize mechanism of user subjective drive. This thesis introduces the historical development of speech synthesis and summarizes the general process of this technique. It is pointed out that prosody generation module is an important part in the process of speech synthesis. On the basis of further research, using eye activity rules when reading to control and drive prosody generation was introduced as a new human-computer interaction method to enrich the synthetic form. In this article, the present situation of speech synthesis technology is reviewed in detail. Based on the premise of eye gaze data extraction, using eye movement signal in real-time driving, a speech synthesis method which can express the real speech rhythm of the speaker is proposed. That is, when reader is watching corpora with its eyes in silent reading, capture the reading information such as the eye gaze duration per prosodic unit, and establish a hierarchical prosodic pattern of duration model to determine the duration parameters of synthesized speech. At last, after the analysis, the feasibility of the above method is verified.

  8. Evaluation of refractive correction for standard automated perimetry in eyes wearing multifocal contact lenses

    Directory of Open Access Journals (Sweden)

    Kazunori Hirasawa

    2017-10-01

    Full Text Available AIM: To evaluate the refractive correction for standard automated perimetry (SAP in eyes with refractive multifocal contact lenses (CL in healthy young participants. METHODS: Twenty-nine eyes of 29 participants were included. Accommodation was paralyzed in all participants with 1% cyclopentolate hydrochloride. SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions: monofocal CL corrected for near distance (baseline; multifocal CL corrected for distance (mCL-D; and mCL-D corrected for near vision using a spectacle lens (mCL-N. Primary outcome measures were the foveal threshold, mean deviation (MD, and pattern standard deviation (PSD. RESULTS: The foveal threshold of mCL-N with both the 24-2 and 10-2 protocols significantly decreased by 2.2-2.5 dB CONCLUSION: Despite the induced mydriasis and the optical design of the multifocal lens used in this study, our results indicated that, when the dome-shaped visual field test is performed with eyes with large pupils and wearing refractive multifocal CLs, distance correction without additional near correction is to be recommended.

  9. Clinical efficacy of pranoprofen and sodium hyaluronate for dry eye

    Directory of Open Access Journals (Sweden)

    Hong-Chao Hou

    2016-01-01

    Full Text Available AIM:To observe the clinical efficacy of pranoprofen and sodium hyaluronate for dry eye, and to provide the reference for clinical treatment of dry eye. METHODS: From January 2012 to January 2015 inour hospital, 106 patients with dry eye were tested and observed. In accordance with the number table, patients were divided into observation group and control group, 53 patients in the control group using conventional treatment plus single sodium hyaluronate eye drops, observation group using pranoprofen combined sodium hyaluronate eye drops, besides conventional treatment. Clinical outcomes between the two groups before and after treatments, dry eye score, fluorescein staining score, Schirmer I test and tear film break up time(BUTwere observed and analyzed. RESULTS:The effective rates of the two groups were 94.3%(50/53and 84.9%(45/53. Dry eye score of observation group before and after treatment were 3.24±0.52 and 0.32±0.06points, those of the control group were 3.26±0.48 and 0.75±0.24points. BUT of the experimental group before and after treatments were 5.67±3.052 and 12.95±2.865s, those of the control group were 6.23±2.985 and 9.85±2.714s.The differences between the two groups on the indicators above were statistically significant(PCONCLUSION: The combination of pranoprofen and sodium hyaluronate for the treatment of dry eye is effective, with high security and water holding capacity, which can improve the symptoms of dry eye and the patients' life quality.

  10. Basal ganglia neuronal activity during scanning eye movements in Parkinson's disease.

    Directory of Open Access Journals (Sweden)

    Tomáš Sieger

    Full Text Available The oculomotor role of the basal ganglia has been supported by extensive evidence, although their role in scanning eye movements is poorly understood. Nineteen Parkinsońs disease patients, which underwent implantation of deep brain stimulation electrodes, were investigated with simultaneous intraoperative microelectrode recordings and single channel electrooculography in a scanning eye movement task by viewing a series of colored pictures selected from the International Affective Picture System. Four patients additionally underwent a visually guided saccade task. Microelectrode recordings were analyzed selectively from the subthalamic nucleus, substantia nigra pars reticulata and from the globus pallidus by the WaveClus program which allowed for detection and sorting of individual neurons. The relationship between neuronal firing rate and eye movements was studied by crosscorrelation analysis. Out of 183 neurons that were detected, 130 were found in the subthalamic nucleus, 30 in the substantia nigra and 23 in the globus pallidus. Twenty percent of the neurons in each of these structures showed eye movement-related activity. Neurons related to scanning eye movements were mostly unrelated to the visually guided saccades. We conclude that a relatively large number of basal ganglia neurons are involved in eye motion control. Surprisingly, neurons related to scanning eye movements differed from neurons activated during saccades suggesting functional specialization and segregation of both systems for eye movement control.

  11. Basal ganglia neuronal activity during scanning eye movements in Parkinson's disease.

    Science.gov (United States)

    Sieger, Tomáš; Bonnet, Cecilia; Serranová, Tereza; Wild, Jiří; Novák, Daniel; Růžička, Filip; Urgošík, Dušan; Růžička, Evžen; Gaymard, Bertrand; Jech, Robert

    2013-01-01

    The oculomotor role of the basal ganglia has been supported by extensive evidence, although their role in scanning eye movements is poorly understood. Nineteen Parkinsońs disease patients, which underwent implantation of deep brain stimulation electrodes, were investigated with simultaneous intraoperative microelectrode recordings and single channel electrooculography in a scanning eye movement task by viewing a series of colored pictures selected from the International Affective Picture System. Four patients additionally underwent a visually guided saccade task. Microelectrode recordings were analyzed selectively from the subthalamic nucleus, substantia nigra pars reticulata and from the globus pallidus by the WaveClus program which allowed for detection and sorting of individual neurons. The relationship between neuronal firing rate and eye movements was studied by crosscorrelation analysis. Out of 183 neurons that were detected, 130 were found in the subthalamic nucleus, 30 in the substantia nigra and 23 in the globus pallidus. Twenty percent of the neurons in each of these structures showed eye movement-related activity. Neurons related to scanning eye movements were mostly unrelated to the visually guided saccades. We conclude that a relatively large number of basal ganglia neurons are involved in eye motion control. Surprisingly, neurons related to scanning eye movements differed from neurons activated during saccades suggesting functional specialization and segregation of both systems for eye movement control.

  12. Extended release of hyaluronic acid from hydrogel contact lenses for dry eye syndrome.

    Science.gov (United States)

    Maulvi, Furqan A; Soni, Tejal G; Shah, Dinesh O

    2015-01-01

    Current dry eye treatment includes delivering comfort enhancing agents to the eye via eye drops, but low residence time of eye drops leads to low bioavailability. Frequent administration leads to incompliance in patients, so there is a great need for medical device such as contact lenses to treat dry eye. Studies in the past have demonstrated the efficacy of hyaluronic acid (HA) in the treatment of dry eyes using eye drops. In this paper, we present two methods to load HA in hydrogel contact lenses, soaking method and direct entrapment. The contact lenses were characterized by studying their optical and physical properties to determine their suitability as extended wear contact lenses. HA-laden hydrogel contact lenses prepared by soaking method showed release up to 48 h with acceptable physical and optical properties. Hydrogel contact lenses prepared by direct entrapment method showed significant sustained release in comparison to soaking method. HA entrapped in hydrogels resulted in reduction in % transmittance, sodium ion permeability and surface contact angle, while increase in % swelling. The impact on each of these properties was proportional to HA loading. The batch with 200-μg HA loading showed all acceptable values (parameters) for contact lens use. Results of cytotoxicity study indicated the safety of hydrogel contact lenses. In vivo pharmacokinetics studies in rabbit tear fluid showed dramatic increase in HA mean residence time and area under the curve with lenses in comparison to eye drop treatment. The study demonstrates the promising potential of delivering HA through contact lenses for the treatment of dry eye syndrome.

  13. EyeGrip: Detecting Targets in a Series of Uni-directional Moving Objects Using Optokinetic Nystagmus Eye Movements

    DEFF Research Database (Denmark)

    Jalaliniya, Shahram; Mardanbeigi, Diako

    2016-01-01

    computers. In this paper, we demonstrate the rich capabilities of EyeGrip with two example applications: 1) a mind reading game, and 2) a picture selection system. Our study shows that by selecting an appropriate speed and maximum number of visible images in the screen the proposed method can be used...

  14. Personality and Total Health Through Life Project Eye Substudy: Methodology and Baseline Retinal Features.

    Science.gov (United States)

    Wijngaarden, Peter Van; Keel, Stuart; Hodgson, Lauren A B; Kumar, Dinesh K; Aliahmad, Behzad; Paim, Cistiane C; Kiely, Kim M; Cherbuin, Nicolas; Anstey, Kaarin J; Dirani, Mohamed

    2017-01-01

    To describe the methodology and present the retinal grading findings of an older sample of australians with well-defined indices of neurocognitive function in the Personality and total Health (PATH) through life project. A cross-sectional study. Three hundred twenty-six individuals from the PatH through life project were invited to participate. Participants completed a general questionnaire and 2-field, 45-degree nonmydriatic color digital retinal photography. Photographs were graded for retinal pathology according to established protocols. Two hundred fifty-four (77.9%) subjects, aged 72 to 78 years, agreed to participate in the eye substudy. gradable images of at least 1 eye were acquired in 211 of 254 subjects (83.1%). retinal photographic screening identified 1 or more signs of pathology in 130 of the 174 subjects (74.7%) with gradable images of both eyes. a total of 45 participants (17.7%) had self-reported diabetes and diabetic retinopathy was observed in 22 (48.9%) of these participants. This well-defined sample of older australians provides a unique opportunity to interrogate associations between retinal findings, including retinal vascular geometric parameters, and indices of neurocognitive function. Copyright 2017 Asia-Pacific Academy of Ophthalmology.

  15. Eye wash water flow direction study: an evaluation of the effectiveness of eye wash devices with opposite directional water flow.

    Science.gov (United States)

    Fogt, Jennifer S; Jones-Jordan, Lisa A; Barr, Joseph T

    2018-01-01

    New designs of eye wash stations have been developed in which the direction of water flow from the fountain has been reversed, with two water streams originating nasally in both eyes and flowing toward the temporal side of each eye. No study has been done to determine the ideal direction of water flow coming from the eye wash in relation to the eye. Ophthalmic eye examinations were conducted before and after the use of two eye wash stations with opposite water flow directionality. Fluorescein was instilled in both eyes before using an eye wash to measure the effectiveness of the water flow. Subjects were surveyed upon their experiences using the eye washes. Ophthalmic examination found no significant difference in the efficacy of the eye washes with nasal-to-temporal water flow when compared to temporal-to-nasal water flow direction.

  16. Analysis of stress-strain state of a human eye by the method of elastotonometry after the surgical correction of hyperopia

    Science.gov (United States)

    Bauer, S. M.; Venatovskaya, L. A.

    2018-05-01

    The mathematical model of measuring of the intraocular pressure (IOP) by Maklakoff tonometer in the software package ANSYS, Inc. is presented. The dependence of the tonometric pressure on the weight of the tonometer before and after LASIK and Femto LASIK surgical corrections of hyperopia is analized. Cornea-scleral eye shell is modeled as two thin transversely isotropic joint spherical shells with different radii of curvature and biomechanical properties. To analyze the biomechanical state of the corneoscleral shell of the eye after the surgery the elastotonometry method is used. Firstly sequential measurements of intraocular pressure by Maklakoff tonometers weighting 5; 7.5; 10 and 15 g is carried out, then the dependence curve of tonometric IOP vs. tonometer weight is plotted and analyzed. The results of the calculations are compared with the clinical data.

  17. Severe dry-eye syndrome following external beam irradiation

    International Nuclear Information System (INIS)

    Parsons, J.T.; Bova, F.J.; Million, R.R.

    1994-01-01

    There are limited data in the literature on the probability of dry-eye complications according to radiotherapy dose. This study investigates the risk of radiation-induced severe dry-eye syndrome in patients in whom an entire orbit was exposed to fractionated external beam irradiation. Between October 1964 and May 1989, 33 patients with extracranial head and neck tumors received irradiation of an entire orbit. Most patients were treated with 60 Co. The dose to the lacrimal apparatus was calculated at a depth of 1 cm from the anterior skin surface, the approximate depth of the major lacrimal gland. The end point of the study was severe dry-eye syndrome sufficient to produce visual loss secondary to corneal opacification, ulceration, or vascularization. Twenty patients developed severe dry-eye syndrome. All 17 patients who received dose ≥57Gy developed severe dry-eye syndrome. Three (19%) of 16 patients who received doses ≥45 Gy developed severe dry-eye syndrome; injuries in the latter group were much more slower to develop (4 to 11 years) than in the higher dose group, in whom corneal vascularization and opacification were usually pronounced within 9-10 months. There were no data for the range of doses between 45.01 and 56.99 Gy. The data did not suggest an increased risk of severe dry-eye syndrome with increasing age. Data from the current series and the literature are combined to construct a sigmoid dose response curve. The incidence of injury increases from 0% reported after doses ≥30 Gy to 100% after doses ≥57 Gy. 13 refs., 3 figs., 5 tabs

  18. Two-step method for creating a gastric tube during laparoscopic-thoracoscopic Ivor-Lewis esophagectomy.

    Science.gov (United States)

    Liu, Yu; Li, Ji-Jia; Zu, Peng; Liu, Hong-Xu; Yu, Zhan-Wu; Ren, Yi

    2017-12-07

    To introduce a two-step method for creating a gastric tube during laparoscopic-thoracoscopic Ivor-Lewis esophagectomy and assess its clinical application. One hundred and twenty-two patients with middle or lower esophageal cancer who underwent laparoscopic-thoracoscopic Ivor-Lewis esophagectomy at Liaoning Cancer Hospital and Institute from March 2014 to March 2016 were included in this study, and divided into two groups based on the procedure used for creating a gastric tube. One group used a two-step method for creating a gastric tube, and the other group used the conventional method. The two groups were compared regarding the operating time, surgical complications, and number of stapler cartridges used. The mean operating time was significantly shorter in the two-step method group than in the conventional method group [238 (179-293) min vs 272 (189-347) min, P creating a gastric tube during laparoscopic-thoracoscopic Ivor-Lewis esophagectomy has the advantages of simple operation, minimal damage to the tubular stomach, and reduced use of stapler cartridges.

  19. Different schematic eyes and their accuracy to the in vivo eye: a quantitative comparison study

    OpenAIRE

    Almeida, Marina Storani de; Carvalho, Luis Alberto

    2007-01-01

    Current ophthalmic technology allows the manipulation of eye components, such as anterior cornea and lens, of the human eye with a considerable precision and customization. This technology opens up the possibility of exploiting some characteristics of the eye in order to improve the methods of correcting optical aberrations. Moreover, product development and research for the eye-care professional has reached very high standards, since there is nowadays software available to design and simulat...

  20. Effects of PUVA on the eye

    International Nuclear Information System (INIS)

    Backman, H.A.

    1982-01-01

    Psoriasis is a common skin disease which may be treated with 8-methoxy psoralen and long-wave ultraviolet light (PUVA). Eye protection is provided during and after treatment to prevent the development of photokeratitis and cataracts. Fifteen patients, treated with medication and ultraviolet A (UVA) had an initial complete eye examination and a repeat examination after each treatment. No patients developed cataracts but almost one-half of the patients had a mild form of photokeratoconjunctivitis. The ocular manifestations included photophobia, conjunctivitis, keratitis, and dry eyes. Tear break-up time was reduced significantly immediately after treatment for two patients but returned to normal 8 hr later. Dermatologists who employ PUVA treatments should be concerned about photokeratoconjunctivitis and the dry-eye ocular manifestations included photophobia, conjunctivitis, keratitis, and dry eyes. Tear break-up time was reduced significantly immediately after treatment for two patients but returned to normal 8 hr later. Dermatologists who employ PUVA treatments should be concerned about photokeratoconjunctivitis and the dry-eye ocular manifestations included photophobia, conjunctivitis, keratitis, and dry eyes. Tear break-up time was reduced significantly immediately after treatment for two patients but returned to normal 8 hr later. Dermatologists who employ PUVA treatments should be concerned about photokeratoconjunctivitis and the dry-eye syndrome

  1. Chapter 2. Eyes

    International Nuclear Information System (INIS)

    Blanquet, P.

    1975-01-01

    Ocular scintigraphy can now be carried out with several tracers: 131 I diiodofluorescein and sup(99m)Tc, hypervascularisation indicators; 131 I iodinated chloroquine, melanoma selective. The detector used is an Anger scintillation camera coupled to a multiparameter analysis chain or a computer. The ''pin-hole'' type collimator, which has a stenopaeic opening in front of each eye, is adaptable to any inter-pupil distance. The very simple scintigraphic procedure is described. The results, taken from two statistical studies on 198 and 80 patients respectively, concern the main types of eye disease encountered: malignant melanic tumours, other tumours, metastases, choroiditis, idiopathic detachments of the retina etc... The interpretation of the scintigrams and the problems involved are considered. Finally the main indications of the method are defined with emphasis on the possibilities of double scintigraphy, diiodofluorescein only showing up the hypervascularisation often associated with the tumour whereas iodinated chloroquine, when the result is positive, points to the presence of a malignant melanoma [fr

  2. The Tromsø Eye Study

    DEFF Research Database (Denmark)

    Bertelsen, Geir; Erke, Maja G; von Hanno, Therese

    2013-01-01

    Purpose:  To describe the study design and methodology of the Tromsø Eye Study (TES), and to describe visual acuity and refractive error in the study population. Methods:  The Tromsø Eye Study is a sub-study of the Tromsø Study, a population-based multipurpose longitudinal study in the municipality...... of Tromsø, Norway. The Tromsø Eye Study was a part of the sixth survey of the Tromsø Study, conducted from October 2007 through December 2008. The eye examination included information on self-reported eye diseases, assessment of visual acuity and refractive errors, retinal photography and optical coherence...

  3. Tear osmolarity measurements in dry eye related to primary Sjögren's syndrome.

    Science.gov (United States)

    Utine, Canan Asli; Bıçakçıgil, Müge; Yavuz, Sule; Çiftçi, Ferda

    2011-08-01

    To evaluate the tear osmolarity in patients with dry eye syndrome related to primary Sjögren's Syndrome (SS). Twenty eyes of 10 patients with dry eye and primary SS (Group 1) and 20 eyes of 20 subjects who do not have dry eye syndrome (Group 2) were included in this cross-sectional study. In all eyes, ophthalmic examination was performed in the same order: International Ocular Surface Disease Index survey, visual acuity assessment, conjunctival hyperemia scoring, tear osmolarity measurement with TearLab(™) Osmolarity System, tear film break-up time assessment, corneal fluorescein staining scoring, ocular surface Lissamine Green staining scoring, anesthetized Schirmer test. Dry eye severity was graded according to Dry Eye Workshop (DEWS) classification system. Four eyes with grade 1, four eyes with grade 2, seven eyes with grade 3, and five eyes with grade 4 dryness, according to DEWS system, were included. The mean tear osmolarity value was 301.9 ± 11.40 mOsm/L (range: 290-328) in Group 1, and 294.85 ± 8.33 mOsm/L (range: 283-311) in Group 2 (p = 0.03). In Group 1, tear osmolarity values were positively correlated with OSDI scores (r(18) = 0.55, r(2) = 0.31, p = 0.01), DEWS classification grades (r(18) = 0.73, r(2) = 0.54, p dry eye syndrome related to primary SS compared to control subjects, and positively correlated with the severity of dry eye.

  4. [Observation on therapeutic effect of dry eye syndrome treated with acupuncture on the acupoints around the eyes].

    Science.gov (United States)

    Gao, Wei-Ping; Liu, Min; Zhang, Yi-Biao

    2010-06-01

    To observed the clinical efficacy on dry eye syndrome treated with acupuncture on the acupoints around the eyes. Fifty-six cases of dry eye syndrome were divided into two groups, acupuncture group and western medicine group, 28 cases in each one. In acupuncture group, acupuncture was applied to Jingming (BL 1), Cuanzhu (BL 2), Sizhukong (TE 23), Tongziliao (GB 1), etc. In western medicine group, the topical artificial tear eye drops were administered. The corneal fluorescein staining, breaking-up time (BUT), tear volume and the symptom score were observed before and after treatment in two groups. In comparison before and after treatment in acupuncture group, the statistical significant difference presented in BUT, tear volume and the symptom score (all P eyes achieves a quite good efficacy on dry eye syndrome.

  5. Agreement between optical coherence tomography and fundus fluorescein angiography in post-cataract surgery cystoid macular edema

    Directory of Open Access Journals (Sweden)

    Mitne Somaia

    2003-01-01

    Full Text Available PURPOSE: To evaluate the agreement between optical coherence tomography (OCT and fundus fluorescein angiography (FFA regarding the detection of cystoid macular edema (CME following cataract surgery. METHODS: Retrospective comparative observational series of 25 eyes with suspected CME. Patients with low visual acuity and alterations in fundus biomicroscopy after cataract surgery underwent OCT scanning followed by FFA on the same visit. The diagnosis of CME was established considering fluorescein leakage on FFA and retinal thickness and/or cystoid spaces and/or subretinal fluid on OCT. RESULTS: Twenty-five eyes of 25 patients were enrolled. Twenty-two eyes had similar results on both OCT and FFA, of which 15 eyes had CME and 7 eyes had no CME. Two eyes had CME detected only by FFA and one eye only by OCT. The agreement between the two examinations was good (Kappa = 0.7331; p=0.0001 with no tendency to have neither more positive nor negative findings (p=1.0. CONCLUSION: According to these preliminary data, OCT seems to be as effective as FFA to detect CME with a good agreement between the two techniques.

  6. Intermediate view synthesis for eye-gazing

    Science.gov (United States)

    Baek, Eu-Ttuem; Ho, Yo-Sung

    2015-01-01

    Nonverbal communication, also known as body language, is an important form of communication. Nonverbal behaviors such as posture, eye contact, and gestures send strong messages. In regard to nonverbal communication, eye contact is one of the most important forms that an individual can use. However, lack of eye contact occurs when we use video conferencing system. The disparity between locations of the eyes and a camera gets in the way of eye contact. The lock of eye gazing can give unapproachable and unpleasant feeling. In this paper, we proposed an eye gazing correction for video conferencing. We use two cameras installed at the top and the bottom of the television. The captured two images are rendered with 2D warping at virtual position. We implement view morphing to the detected face, and synthesize the face and the warped image. Experimental results verify that the proposed system is effective in generating natural gaze-corrected images.

  7. Efficacy of corneal eye shields in protecting patients' eyes from laser irradiation.

    Science.gov (United States)

    Russell, S W; Dinehart, S M; Davis, I; Flock, S T

    1996-07-01

    The continuing development of new types and applications of lasers has appeared to surpass the development of specific eye protection for these lasers. There are a variety of eye shields on the market, but few are specifically designed for laser protection. Our purpose was to test a variety of eye shields by two parameters, light transmission and temperature rise, and to determine from these measurements the most protective shield for patients. We tested four plastic shields, one metal shield, and two sets of tanning goggles for temperature rise and light transmission when irradiated with a beam from a flashlamp-pumped, pulsed-dye laser. The temperature rise at the surface of the shield opposite the laser impacts was no more than 0.2 degree C in any case. White light was transmitted at significant levels through several of the shields, but yellow light transmittance was noted only through the green eye shield. Our measurements indicate that all except the green shield appeared safe from transmission of the 585-nm radiant energy. However, the optimal laser eye shield, in our opinion, would be a composite of several different shields' characteristics.

  8. Evaluation of a new electronic preoperative reference marker for toric intraocular lens implantation by two different methods of analysis: Adobe Photoshop versus iTrace.

    Science.gov (United States)

    Farooqui, Javed Hussain; Sharma, Mansi; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2017-01-01

    The aim of this study is to compare two different methods of analysis of preoperative reference marking for toric intraocular lens (IOL) after marking with an electronic marker. Cataract and IOL Implantation Service, Shroff Eye Centre, New Delhi, India. Fifty-two eyes of thirty patients planned for toric IOL implantation were included in the study. All patients had preoperative marking performed with an electronic preoperative two-step toric IOL reference marker (ASICO AE-2929). Reference marks were placed at 3-and 9-o'clock positions. Marks were analyzed with two systems. First, slit-lamp photographs taken and analyzed using Adobe Photoshop (version 7.0). Second, Tracey iTrace Visual Function Analyzer (version 5.1.1) was used for capturing corneal topograph examination and position of marks noted. Amount of alignment error was calculated. Mean absolute rotation error was 2.38 ± 1.78° by Photoshop and 2.87 ± 2.03° by iTrace which was not statistically significant ( P = 0.215). Nearly 72.7% of eyes by Photoshop and 61.4% by iTrace had rotation error ≤3° ( P = 0.359); and 90.9% of eyes by Photoshop and 81.8% by iTrace had rotation error ≤5° ( P = 0.344). No significant difference in absolute amount of rotation between eyes when analyzed by either method. Difference in reference mark positions when analyzed by two systems suggests the presence of varying cyclotorsion at different points of time. Both analysis methods showed an approximately 3° of alignment error, which could contribute to 10% loss of astigmatic correction of toric IOL. This can be further compounded by intra-operative marking errors and final placement of IOL in the bag.

  9. A Fuzzy-Based Fusion Method of Multimodal Sensor-Based Measurements for the Quantitative Evaluation of Eye Fatigue on 3D Displays

    Directory of Open Access Journals (Sweden)

    Jae Won Bang

    2015-05-01

    Full Text Available With the rapid increase of 3-dimensional (3D content, considerable research related to the 3D human factor has been undertaken for quantitatively evaluating visual discomfort, including eye fatigue and dizziness, caused by viewing 3D content. Various modalities such as electroencephalograms (EEGs, biomedical signals, and eye responses have been investigated. However, the majority of the previous research has analyzed each modality separately to measure user eye fatigue. This cannot guarantee the credibility of the resulting eye fatigue evaluations. Therefore, we propose a new method for quantitatively evaluating eye fatigue related to 3D content by combining multimodal measurements. This research is novel for the following four reasons: first, for the evaluation of eye fatigue with high credibility on 3D displays, a fuzzy-based fusion method (FBFM is proposed based on the multimodalities of EEG signals, eye blinking rate (BR, facial temperature (FT, and subjective evaluation (SE; second, to measure a more accurate variation of eye fatigue (before and after watching a 3D display, we obtain the quality scores of EEG signals, eye BR, FT and SE; third, for combining the values of the four modalities we obtain the optimal weights of the EEG signals BR, FT and SE using a fuzzy system based on quality scores; fourth, the quantitative level of the variation of eye fatigue is finally obtained using the weighted sum of the values measured by the four modalities. Experimental results confirm that the effectiveness of the proposed FBFM is greater than other conventional multimodal measurements. Moreover, the credibility of the variations of the eye fatigue using the FBFM before and after watching the 3D display is proven using a t-test and descriptive statistical analysis using effect size.

  10. [Boston keratoprosthesis: 73 eyes from Germany : An overview of experiences from two centers].

    Science.gov (United States)

    Schaub, F; Neuhann, I; Enders, P; Bachmann, B O; Koller, B; Neuhann, T; Cursiefen, C

    2017-10-17

    The Boston Keratoprosthesis (B-KPro) is a therapeutic option for corneal replacement for visual rehabilitation in eyes with poor a prognosis for penetrating keratoplasty (high-risk eyes). Since 2009, this approach has been used in the MVZ Prof. Neuhann, Munich, and since 2013 also at the Department of Ophthalmology, University of Cologne. An overview of results from the first 73 eyes in these departments is presented. All recipient eyes of both centers which received a B-KPro type I (BI-KPro) between November 2009 and March 2017 were included. Indications, preoperative findings, intraoperative procedures, and clinical results, as well as postoperative complication and retention rates were documented and analyzed. A total of 73 eyes from 68 patients (mean age 55 ± 21.1 years, range 7 months-93 years; 26 women, 42 men) were treated with a BI-KPro. In 53 eyes (72.6%) the BI-KPro was implanted due to corneal graft failure, whereas BI-KPro was used as the primary corneal replacement in 20 eyes (27.4%). In 46 eyes (63.0%) a long-term increase in visual acuity was achieved and in 21.9% visual acuity was stabilized, while a decrease in preoperative visual acuity occurred in 15.1% of cases. During an average follow-up of 24.7 ± 23.0 months (range 1-78 months), 1.7 ± 2.4 re-interventions (range 0-9) were required. Only 4 keratoprostheses (5.5%) could not be retained. In 3 eyes (4.2%), a change of the BI-KPro device was necessary. There is a wide range of indications for BI-KPro in eyes with a poor prognosis for conventional keratoplasty. The surgical technique is safe but with a notable postoperative complication rate, which does not seem to decrease in the medium or long term. The retention rate is excellent for eyes without stem cell deficiency. Nevertheless, the BI-KPro is the only therapeutic option for high-risk eyes and leads to a gain in visual acuity in most cases.

  11. Keratomycosis after incidental spillage of vegetative material into the eye: Report of two cases

    Directory of Open Access Journals (Sweden)

    Ali Tabatabaee

    2013-01-01

    Full Text Available Fungal corneal ulcers mostly occur after incidental corneal trauma by plant leaves in farm lands or the use of topical corticosteroids or antibiotics. The infection is more prevalent among farmers and harvesters and in some parts of the world is considered as an occupational disease; however, there have been a few reports on the occurrence of such ulcers in healthy individuals after incidental spillage of vegetative material into the eye. The importance of these ulcers is their long-term and refractory course, which makes the visual prognosis unfavorable in most patients, even after appropriate antifungal therapy or ocular interventions. Herein, we present two rare cases of fungal ulcers caused by incidental spillage of vegetative material into the eye while eating nuts and corn. We also discuss the diagnostic and therapeutic approaches, as well as visual outcome reviewing the relevant literature.

  12. Benefits of switching from latanoprost to preservative-free tafluprost eye drops: a meta-analysis of two Phase IIIb clinical trials

    Directory of Open Access Journals (Sweden)

    Uusitalo H

    2016-03-01

    Full Text Available Hannu Uusitalo,1 Evgeniy Egorov,2 Kai Kaarniranta,3 Yuri Astakhov,4 Auli Ropo5 On behalf of the Switch Study Tafluprost Study Groups 1Department of Ophthalmology, SILK, University of Tampere, Tampere University Hospital, Tampere, Finland; 2Department of Ophthalmology, The Russian National Research Medical University, Moscow, Russia; 3Department of Ophthalmology, University of Eastern Finland, Kuopio University Hospital, Kuopio, Finland, 4Department of Ophthalmology, First Pavlov State Medical University of St Petersburg, Saint Petersburg, Russia, 5Global Medical Affairs, Santen Oy, Tampere, Finland Introduction: Glaucoma patients frequently exhibit ocular surface side effects during treatment with prostaglandin eye drops. The present work investigated whether glaucoma patients suffering from signs and symptoms of ocular surface disease while using preserved latanoprost eye drops benefited from switching to preservative-free tafluprost eye drops. Patients and methods: The analysis was based on 339 glaucoma patients enrolled in two Phase IIIb trials. The patients were required to have two symptoms, or one sign and one symptom of ocular surface disease at baseline, and at least 6 months preceding treatment with latanoprost eye drops preserved with benzalkonium chloride. All eligible patients were switched from latanoprost to preservative-free tafluprost for a total of 12 weeks. Ocular symptoms and ocular signs were evaluated at baseline and at 2 weeks, 6 weeks, and 12 weeks after commencing treatment with tafluprost. Intraocular pressure (IOP, drop discomfort, and treatment preference were evaluated to investigate the clinical efficacy and patient-related outcomes. Results: After 12 weeks of treatment with preservative-free tafluprost, the incidences of irritation/burning/stinging, foreign body sensation, tearing, itching, and dry eye sensation had diminished to one-third of those reported for preserved latanoprost at baseline. The incidences

  13. Clinical observation of Qiming granule combined with Dextran and Hypromellose eye drops for dry eye

    Directory of Open Access Journals (Sweden)

    Jin-Lan Wan

    2013-09-01

    Full Text Available AIM: To observe the efficacy of Qiming granule combined with Dextran and Hypromellose eye drops in treatment of dry eye.METHODS: A randomized, parallel-control approach was adopted, 100 cases of dry eye patients were divided into treatment group and control group equally, observation on the treatment of 3 months. The treatment group was applied Dextran and Hypromellose eye drops combined with oral Qiming granule, simply Dextran and Hypromellose eye drops for control group. Before and after treatment, tear secretion volume, break-up time, corneal fluorescein staining and symptom were observed.RESULTS: After treatment, there was statistical significance for the break-up time, SⅠt and corneal fluorescein staining in both groups when compared with before treatment(PPCONCLUSION: The combined Dextran and Hypromellose eye drops and Qiming granule perform better than Dextran and Hypromellose eye drops only in treatment of dry eye.

  14. Flexible fabrication of biomimetic compound eye array via two-step thermal reflow of simply pre-modeled hierarchic microstructures

    Science.gov (United States)

    Huang, Shengzhou; Li, Mujun; Shen, Lianguan; Qiu, Jinfeng; Zhou, Youquan

    2017-06-01

    A flexible fabrication method for the biomimetic compound eye (BCE) array is proposed. In this method, a triple-layer sandwich-like coating configuration was introduced, and the required hierarchic microstructures are formed with a simple single-scan exposure in maskless digital lithography. Taking advantage of the difference of glass transition point (Tg) between photoresists of each layer, the pre-formed hierarchic microstructures are in turn reflowed to the curved substrate and the BCE ommatidia in a two-step thermal reflow process. To avoid affecting the spherical substrate formed in the first thermal reflow, a non-contact strategy was proposed in the second reflow process. The measurement results were in good agreement with the designed BCE profiles. Results also showed that the fabricated BCE had good performances in optical test. The presented method is flexible, convenient, low-cost and can easily adapt to the fabrications of other optical elements with hierarchic microstructures.

  15. Contact-Free Cognitive Load Recognition Based on Eye Movement

    Directory of Open Access Journals (Sweden)

    Xin Liu

    2016-01-01

    Full Text Available The cognitive overload not only affects the physical and mental diseases, but also affects the work efficiency and safety. Hence, the research of measuring cognitive load has been an important part of cognitive load theory. In this paper, we proposed a method to identify the state of cognitive load by using eye movement data in a noncontact manner. We designed a visual experiment to elicit human’s cognitive load as high and low state in two light intense environments and recorded the eye movement data in this whole process. Twelve salient features of the eye movement were selected by using statistic test. Algorithms for processing some features are proposed for increasing the recognition rate. Finally we used the support vector machine (SVM to classify high and low cognitive load. The experimental results show that the method can achieve 90.25% accuracy in light controlled condition.

  16. Intraocular Telescopic System Design: Optical and Visual Simulation in a Human Eye Model

    OpenAIRE

    Zoulinakis, Georgios; Ferrer-Blasco, Teresa

    2017-01-01

    Purpose. To design an intraocular telescopic system (ITS) for magnifying retinal image and to simulate its optical and visual performance after implantation in a human eye model. Methods. Design and simulation were carried out with a ray-tracing and optical design software. Two different ITS were designed, and their visual performance was simulated using the Liou-Brennan eye model. The difference between the ITS was their lenses’ placement in the eye model and their powers. Ray tracing in bot...

  17. Importance of non-synonymous OCA2 variants in human eye colour prediction

    DEFF Research Database (Denmark)

    Andersen, Jeppe Dyrberg; Pietroni, Carlotta; Johansen, Peter

    2016-01-01

    in the promotor region of OCA2 (OMIM #611409). Nevertheless, many eye colors cannot be explained by only considering rs12913832:A>G. Methods: In this study, we searched for additional variants in OCA2 to explain human eye color by sequencing a 500 kbp region, encompassing OCA2 and its promotor region. Results: We...... identified three nonsynonymous OCA2 variants as important for eye color, including rs1800407:G>A (p.Arg419Gln) and two variants, rs74653330:A>T (p.Ala481Thr) and rs121918166:G>A (p.Val443Ile), not previously described as important for eye color variation. It was shown that estimated haplotypes consisting...

  18. How to Research People's First Impressions of Websites? Eye-Tracking as a Usability Inspection Method and Online Focus Group Research

    Science.gov (United States)

    Herendy, Csilla

    The visual surface of the Hungarian governmental portal - magyarorszag.hu - was inspected in 2007 with two different inspection methods: Eye tacking research and Online focus group research. Both methods help to understand and to chart not only the usability of different websites but also the affective imp ressions associated with the websites. In this study, an Experimental and a Control-group were tested to assess the usability of the site and the emotional re actions to it. The results reveal that the Hungarian government website is too complicated, dull and difficult to apprehend at a glance.

  19. How are learning strategies reflected in the eyes? Combining results from self-reports and eye-tracking.

    Science.gov (United States)

    Catrysse, Leen; Gijbels, David; Donche, Vincent; De Maeyer, Sven; Lesterhuis, Marije; Van den Bossche, Piet

    2018-03-01

    Up until now, empirical studies in the Student Approaches to Learning field have mainly been focused on the use of self-report instruments, such as interviews and questionnaires, to uncover differences in students' general preferences towards learning strategies, but have focused less on the use of task-specific and online measures. This study aimed at extending current research on students' learning strategies by combining general and task-specific measurements of students' learning strategies using both offline and online measures. We want to clarify how students process learning contents and to what extent this is related to their self-report of learning strategies. Twenty students with different generic learning profiles (according to self-report questionnaires) read an expository text, while their eye movements were registered to answer questions on the content afterwards. Eye-tracking data were analysed with generalized linear mixed-effects models. The results indicate that students with an all-high profile, combining both deep and surface learning strategies, spend more time on rereading the text than students with an all-low profile, scoring low on both learning strategies. This study showed that we can use eye-tracking to distinguish very strategic students, characterized using cognitive processing and regulation strategies, from low strategic students, characterized by a lack of cognitive and regulation strategies. These students processed the expository text according to how they self-reported. © 2017 The British Psychological Society.

  20. Surgical and visual outcomes of retinal detachment surgery in eyes with chorio-retinal coloboma

    International Nuclear Information System (INIS)

    Zafar, S.A.; Qureshi, N.A.; Pathan, A.H.K.

    2016-01-01

    Objective: To evaluate the anatomical and visual outcome of surgical management of retinal detachment associated with chorio-retinal coloboma. Study Design: Prospective interventional case series Place and Duration of Study: This study was conducted at Al-Shifa Trust Eye Hospital Rawalpindi from Jan 2012 to Dec 2013. Material and Methods: Twenty one eyes (21 patients) that underwent surgery for retinal detachment associated with chorio-retinal colobomas were selected. Evaluation was done on the basis of type of intervention, final visual acuity and anatomical outcome and complications. Out of 21, 19(90.47 percent) eyes underwent pars plana vitrectomy with silicone oil (SO) and 2(9.52 percent) underwent primary scleral buckling surgery. SO was removed in 9 (47.36 percent) eyes at final follow up. Encircling band was placed in 12 (63.15 percent) eyes based on peroperative judgment of surgeon. Intra-operative lensectomy was performed in 6 (28.57 percent) eyes. The main outcome measures were retinal re-attachment and visual recovery. Statistical analysis was performed using IBM statistical package for social sciences (SPSS) Statistics (version 17.0, Chicago, Illinois, USA). Qualitative variables were described using percentage; quantitative data were defined using mean +- standard deviation. The pre op and post op frequency of best corrected visual acuity (BVA) was compared using Wilcoxan Signed Ranks Test. Confidence interval was 95 percent (level of significance p<0.05). Results: The mean number of operations per eye were 1.57+- 0.74; mean follow-up was 13.1 months (range 12-18). The retina remained attached in 18 eyes (85.71 percent) at final follow-up. The post op BCVA improved significantly as compared to pre op BCVA (p< 0.01). Mean pre op BCVA was counting fingers (CF) and mean post op value of BCVA was 3/60. Conclusion: Pars plana vitrectomy along with silicon oil tamponade for retinal detachment related to choroiretinal coloboma improves the long

  1. Establishment of a new in vitro test method for evaluation of eye irritancy using a reconstructed human corneal epithelial model, LabCyte CORNEA-MODEL.

    Science.gov (United States)

    Katoh, Masakazu; Hamajima, Fumiyasu; Ogasawara, Takahiro; Hata, Ken-ichiro

    2013-12-01

    Finding in vitro eye irritation testing alternatives to animal testing such as the Draize eye test, which uses rabbits, is essential from the standpoint of animal welfare. It has been developed a reconstructed human corneal epithelial model, the LabCyte CORNEA-MODEL, which has a representative corneal epithelium-like structure. Protocol optimization (pre-validation study) was examined in order to establish a new alternative method for eye irritancy evaluation with this model. From the results of the optimization experiments, the application periods for chemicals were set at 1min for liquid chemicals or 24h for solid chemicals, and the post-exposure incubation periods were set at 24h for liquids or zero for solids. If the viability was less than 50%, the chemical was judged to be an eye irritant. Sixty-one chemicals were applied in the optimized protocol using the LabCyte CORNEA-MODEL and these results were evaluated in correlation with in vivo results. The predictions of the optimized LabCyte CORNEA-MODEL eye irritation test methods were highly correlated with in vivo eye irritation (sensitivity 100%, specificity 80.0%, and accuracy 91.8%). These results suggest that the LabCyte CORNEA-MODEL eye irritation test could be useful as an alternative method to the Draize eye test. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Dry eye following cataract surgery in Women Over 50 Years Old

    Directory of Open Access Journals (Sweden)

    N. Bazzazi

    2016-11-01

    Full Text Available Introduction: Dry eye is a common problem amongst post-menopausal women. Cataract surgery may worsen symptoms of dry eye and this can inflence the quality of life in patients. Ths study was performed to evaluate the incidence and severity of dry eye symptoms aftr phacoemulsifiation surgery. Methods: Ths case-series study was performed on 43 women aged over 50 years during 2013-2014. Patients underwent phacoemulsifiation surgery on one eye. Symptoms of the operated and contra lateral eye were analyzed by χ2 statistical test and SPSS softare, preoperative and one month aftr the surgery. Results: One month aftr the surgery, the mean value of incidence and severity of dry eye in operated and non-operated eyes were 90.06 ± 3.5, 80.96 ± 3.55, 71.11 ± 3.52, and 63.51 ± 3.04, respectively. Th diffrence between the two groups was signifiant (P > 0.001. Schirmer’s test, TBUT and corneal staining showed no signifiant diffrence (P ≥ 0.05. conclusions: Cataract surgery may lead to worsening of dry eye symptoms. Treatment of dry eye before cataract surgery is an important issue to prevent ocular surface damage.

  3. Influence of preoperative artificial tears on tear film after phacoemulsification on dry eye of diabetes patients

    Directory of Open Access Journals (Sweden)

    Rui Su

    2015-05-01

    Full Text Available AIM: To discuss the artificial tears on the tear film of diabetic patients with dry eye preoperatively, and the influence on the tear film's fuctional after phacoemulsification.METHODS: Fifty-four diabetic patients with dry eye(60 eyeswere followed up before phacoemulsification. Preoperatively, group A(30 eyes in 28 caseswas treated with Hydroxyl Indican eye drops and group B(30 eyes in 26 caseswas not treated. Postoperatively, both group A and B were treated with Tobramycin Dexamethasone eye drops, Oprah Winfrey Ibuprofen eye drops and Hydroxyl Indican eye drops. Dry eye symptoms, break up time(BUT, Schirmer Ⅰ test(S Ⅰ t, fluorescein stain test(FIwere measured at 3d preoperatively, and 1, 7, 30, 90d postoperatively.RESULTS: At 3d preoperatively, there was no statistical differences between the two groups for dry eye symptoms, BUT, SⅠt, FI(P>0.05. At 1 and 7d postoperatively, there were significant statistical differents between the two groups for dry eye symptoms(PPP>0.05.CONCLUSION: Using artificial tears before phacoemulsification can improve symptoms of the diabetic patients with dry eye and accelerate the recovery of the tear film.

  4. Ropes eye plaque brachytherapy dosimetry for two models of 103Pd seeds

    International Nuclear Information System (INIS)

    Saidi, P.; Sadeghi, M.; Shirazi, A.; Tenreiro, C.

    2011-01-01

    Full text: Brachytherapy dose distributions are calculated for I5 m m ROPES eye plaque loaded with model Theragenics200 and IR06-103Pd seeds. The effects of stainless steel backing and Acrylic insert on dose distribution along the central axis of the eye plaque and at critical ocular structure are investigated. Monte Carlo simulation was carried out with the Version 5 of the MCNP. The dose at critical ocular structure by considering the eye composition was calculated. Results are compared with the calculated data for CaMS eye plaque loaded with Theragenics200 palladium-103 seeds and model 6711 iodine-125 seed. The air kerma strength of the IR06- 103Pd seed to deliver 85 Gy in apex of tumor in water medium was calculated to be 4.10 U/seed. Along the central axis of stainless steel plaque loaded with new 103Pd seeds in Acrylic insert, the dose reduction relative to water is 6.9% at 5 mm (apex). Removal of the Acrylic insert from the plaque (replacing with water) did not make significantly difference in dose reduction results (O.2%). The presence of the stainless steel backing results in dose enhancement near the plaque relative to water. Doses at points of interest are higher for ROPES eye plaque when compared to CaMS eye plaque. The dosimetric parameters calculated in this work for the new palladium seed, showed that in dosimetry point of view, the IR06-103Pd seed is suitable for use in brachytherapy. The effect of Acrylic insert on dose distribution is negligible and the main effect on dose reduction is due to the presence of stainless steel plaque backing. (author)

  5. Accuracy and reliability of the Keeler Pulsair EasyEye non-contact tonometer.

    Science.gov (United States)

    Ogbuehi, Kelechi C; Almubrad, Turki M

    2008-01-01

    To evaluate the accuracy and reliability of the Keeler Pulsair EasyEye noncontact tonometer in a normotensive population. This masked prospective clinical study included 72 right eyes of 72 subjects. Two sets of intraocular pressure measurements were made 1 week apart. Intraocular pressure assessment with the Goldmann tonometer was always subsequent to that with the noncontact tonometer. Each method was assessed for within-session and test-retest repeatability and both methods were assessed for limits of agreement, twice. The level of significance for this study was 0.05. Both methods were repeatable within-sessions to within +/-2 mm Hg, and between sessions to within +/-3 mm Hg. Neither the within-session differences nor the between session differences differed significantly between the Goldmann tonometer and the Pulsair EasyEye noncontact tonometer. The mean differences (+/-SD) between both methods (0.1 +/- 1.6 mm Hg and 0.05 +/- 1.7 mm Hg, for the first and second sessions, respectively) were not statistically significant, but the intraocular pressure measured with the Pulsair EasyEye tonometer was consistently higher than that measured with the Goldmann tonometer. The Pulsair EasyEye noncontact tonometer is considered an accurate reliable method in the normotensive population studied but because of a systematic bias in a small number of subjects, it cannot be used interchangeably with the Goldmann tonometer.

  6. Clinical observation on individualized therapy for dry eye

    Directory of Open Access Journals (Sweden)

    Jing Tang

    2013-05-01

    Full Text Available AIM:To evaluate the efficacy of individualized therapy on dry eye induced by different reasons. METHODS: Totally 140 cases(140 eyesof dry eye were divided into three categories according to eye symptoms. First category: 60 cases(60 eyeswith meibomian gland dysfunction(MGDwere divided into A1 group(palpebralis margin treatment groupand B1 group(control group; Second category: 50 cases(50 eyeswith corneal epithelium damage(corneal fluorescence staining FL Score≥5were divided into A2 group(bandage contact lens groupand B2 group(control group; Third category: 30 cases(30 eyeswith low Schirmer test(Schirmer Ⅰ≤5mmwere divided into A3 group(lacrimal punctum plug groupand B3 group(control group. Both former categories treated by 1g/L fluorometholone eye drops and 1g/L hyaluronate sodium eye drops, but received limbus palpebralis cleaning, oral doxycycline in A1 group and bandage contact lens in A2 group else. The third category was treated by 10g/L cyclosporine A and carbomer eye gel, but lacrimal punctum plug in A3 group before received the drug treatment. Two weeks follow up, each case was examined by subjective symptom, cornea fluorescence colouration test, tear break-up time(BUT, and Schirmer test Ⅰ(SⅠtin the treatment groups(A1,A2,A3and the control groups(B1,B2,B3, the results pre- and post-treatment were compared. The t test was used for inferential statistics. RESULTS: There was no statistical difference between treatment groups(A1, A2, A3and control groups(B1, B2, B3before treatment. Two weeks after treatment, there was statistical difference between the treatment groups(A1, A2, A3and control groups(B1, B2, B3in subjective symptoms and BUT. The difference among A3 group(lacrimal punctum plug group, in which the lacrimal river line formed were observed 2 weeks after treatmentand B3 (control groupwas statistically significant in SⅠt. CONCLUSION:On base of anti-inflammatory and use of artificial tears, individualized therapy is an

  7. Organization of eye bank

    International Nuclear Information System (INIS)

    Reddy, S.C.

    1999-01-01

    Comeal transplantation is the only method of combating the blindness due to corneal opacity caused by infections, malnutrition, trauma and hereditary diseases. Comeal blindness is more prevalent in the developing countries. The availability of the donor cornea, trained ophthalmic surgeons and microsurgery facilities are the key factors in restoring vision in-patients with comeal blindness. The eye bank organization is somewhat similar to that of blood bank. The eye bank should be located in a hospital or a medical centre in which a laboratory may be established for the evaluation and storage of donor tissue. The medical director (Ophthalmologist), technician, secretary and public relation officer are the persons who play an important role in the successful organization of eye bank. The function of the eye bank are procurement, assessment, processing, distribution of donor eyes/corneas, training of technicians/doctors, and conducting research related to storage of donor tissue and corneal transplantation. The necessary infrastructure required for the organization of an eye bank include separate accommodation area for the personnel and the laboratory, telephone, computer, refrigerator, laminar air flow hood. Slitlamp, specular microscope, storage media and equipment, instrument for enucleation of donor eyes, and a motor vehicle. The details of responsibilities of the staff of eye bank, source of donor eyes, suitability of donor material, procurement of the donor cornea, tissue assessment, storage and preservation, distribution of donor tissue, and limitation of eye bank will be discussed at the time of presentation

  8. Seamless interaction with scrolling contents on eyewear computers using optokinetic nystagmus eye movements

    DEFF Research Database (Denmark)

    Jalaliniya, Shahram; Mardanbegi, Diako

    2016-01-01

    In this paper we investigate the utility of an eye-based interaction technique (EyeGrip) for seamless interaction with scrolling contents on eyewear computers. EyeGrip uses Optokinetic Nystagmus (OKN) eye movements to detect object of interest among a set of scrolling contents and automatically s...... a well-known input device. Moreover, the accuracy of the EyeGrip method for menu item selection was higher while in the Facebook study participants found keyboard more accurate.......In this paper we investigate the utility of an eye-based interaction technique (EyeGrip) for seamless interaction with scrolling contents on eyewear computers. EyeGrip uses Optokinetic Nystagmus (OKN) eye movements to detect object of interest among a set of scrolling contents and automatically...... stops scrolling for the user. We empirically evaluated the usability of EyeGrip in two different applications for eyewear computers: 1) a menu scroll viewer and 2) a Facebook newsfeed reader. The results of our study showed that the EyeGrip technique performs as good as keyboard which has long been...

  9. Dynamic scanpaths: eye movement analysis methods

    Science.gov (United States)

    Blackmon, Theodore T.; Ho, Yeuk F.; Chernyak, Dimitri A.; Azzariti, Michela; Stark, Lawrence W.

    1999-05-01

    An eye movements sequence, or scanpath, during viewing of a stationary stimulus has been described as a set of fixations onto regions-of-interest, ROIs, and the saccades or transitions between them. Such scanpaths have high similarity for the same subject and stimulus both in the spatial loci of the ROIs and their sequence; scanpaths also take place during recollection of a previously viewed stimulus, suggesting that they play a similar role in visual memory and recall.

  10. Covering one eye in fixation-disparity measurement causes slight movement of fellow eye

    NARCIS (Netherlands)

    Simonsz, H. J.; Bour, L. J.

    1991-01-01

    In the subjective measurement of fixation disparity (FD), the subject fuses contours presented in the peripheral macular areas of both eyes (fusion lock). The position of the eyes relative to each other is monitored by means of two haploscopically seen vertical lines presented in the central macular

  11. Tracking Eyes using Shape and Appearance

    DEFF Research Database (Denmark)

    Hansen, Dan Witzner; Nielsen, Mads; Hansen, John Paulin

    2002-01-01

    to infer the state of the eye such as eye corners and the pupil location under scale and rotational changes. We use a Gaussian Process interpolation method for gaze determination, which facilitates stability feedback from the system. The use of a learning method for gaze estimation gives more flexibility...

  12. EyeMusic: Making Music with the Eyes

    OpenAIRE

    Hornof, Anthony J.; Sato, Linda

    2004-01-01

    Though musical performers routinely use eye movements to communicate with each other during musical performances, very few performers or composers have used eye tracking devices to direct musical compositions and performances. EyeMusic is a system that uses eye movements as an input to electronic music compositions. The eye movements can directly control the music, or the music can respond to the eyes moving around a visual scene. EyeMusic is implemented so that any composer using established...

  13. Comparative evaluation of twenty pilot workload assessment measure using a psychomotor task in a moving base aircraft simulator

    Science.gov (United States)

    Connor, S. A.; Wierwille, W. W.

    1983-01-01

    A comparison of the sensitivity and intrusion of twenty pilot workload assessment techniques was conducted using a psychomotor loading task in a three degree of freedom moving base aircraft simulator. The twenty techniques included opinion measures, spare mental capacity measures, physiological measures, eye behavior measures, and primary task performance measures. The primary task was an instrument landing system (ILS) approach and landing. All measures were recorded between the outer marker and the middle marker on the approach. Three levels (low, medium, and high) of psychomotor load were obtained by the combined manipulation of windgust disturbance level and simulated aircraft pitch stability. Six instrument rated pilots participated in four seasons lasting approximately three hours each.

  14. Fellow eye treatment in excimer photo refractive keratectomy

    Directory of Open Access Journals (Sweden)

    Rao Srinivas

    2000-01-01

    Full Text Available Purpose: To describe symmetry of response in fellow eyes of patients undergoing photorefractive keratectomy (PRK for myopia, analyse the risk factors leading to asymmetry in response and to determine if delayed treatment of the second eye increases safety and predictability of PRK. Methods: Retrospective review of case records of 133 patients who underwent bilateral myopic PRK and had a minimum follow up of 6 months in both eyes. Results: Postoperative uncorrected visual acuity, spherical equivalent (SE refraction within ±1D of emmetropia, best-corrected visual acuity (BCVA and corneal haze were not significantly different in fellow eyes of patients undergoing PRK for myopia. Of 87 eyes in group 1 (myopia <6D, 96.6% had uncorrected visual acuity ≥6/ 12, 89.7% were within ±1D of emmetropia, none lost ≥1 line BCVA, and none had haze ≥grade 3. Similar results for 98 eyes in group II (myopia 6 to 9.9D were 75.6%, 55.1%, 2.0% and 2.0% respectively. For 81 eyes in group III (myopia ≥ 10D the results were 42.7%, 33.3%, 8.6%, and 4.9% respectively. Among 84 patients with similar preoperative myopia in both eyes, 54 (64.3% patients had a postoperative SE difference ≤ ID in fellow eyes. Risk factors for asymmetric response among fellow eyes included increasing preoperative myopia (p<0.001 and dissimilar treatment technique in the two eyes (p=0.03. Corneal haze did not increase significantly after the third postoperative month. Conclusion: This study demonstrates that considerable symmetry of response exists in fellow eyes of patients undergoing myopic PRK. Early PRK in the fellow eye of patients with < 6 D myopia is safe and allows quick visual rehabilitation of the patient. In patients with myopia ≥6D, a 3-month interval before treating the second eye may improve the safety of the procedure.

  15. Exposure of eyes to perfume: a double-blind, placebo-controlled experiment.

    Science.gov (United States)

    Elberling, J; Duus Johansen, J; Dirksen, A; Mosbech, H

    2006-08-01

    Environmental perfume exposure can elicit bothersome respiratory symptoms. Symptoms are induced at exposure levels which most people find tolerable, and the mechanisms are unclear. The aim of the study was to investigate patients with eye and respiratory symptoms related to environmental perfume, by exposing the eyes to perfume in a double-blind, placebo-controlled study.Twenty-one eczema patients with respiratory symptoms elicited by perfume were compared with 21 healthy volunteers in a sex- and age-matched case-control study. The participants completed a symptom questionnaire, and underwent a double-blind, placebo-controlled exposure to perfume. Of the 42 individuals tested, 10 had more eye symptoms (irritation, itching, and tears) during perfume exposure than during placebo exposures, and eight of these individuals (P = 0.07, Fisher's exact test) belonged to the patient group. A true positive eye reaction to perfume was significantly associated with identification of perfume as an active exposure (P perfume elicited irritation in the eyes independently of olfaction, but the relative importance of ocular chemoperception in relation to elicitation of respiratory symptoms from common environmental exposures to perfume remains unclear. We investigated the hypothesis of an association between respiratory symptoms related to perfume and ocular perfume sensitivity by exposing the eyes to perfume in a double blind, placebo-controlled experiment. Vapors of perfume provoked symptoms in the relevant eye in some patients and healthy control persons, but under our exposure conditions, ocular chemesthesis failed to elicit respiratory symptoms.

  16. Comparison of the biometric values obtained by two different A-mode ultrasound devices (Eye Cubed vs. PalmScan): a transversal, descriptive, and comparative study.

    Science.gov (United States)

    Velez-Montoya, Raul; Shusterman, Eugene Mark; López-Miranda, Miriam Jessica; Mayorquin-Ruiz, Mariana; Salcedo-Villanueva, Guillermo; Quiroz-Mercado, Hugo; Morales-Cantón, Virgilio

    2010-03-24

    To assess the reliability of the measurements obtained with the PalmScan, when compared with another standardized A-mode ultrasound device, and assess the consistency and correlation between the two methods. Transversal, descriptive, and comparative study. We recorded the axial length (AL), anterior chamber depth (ACD) and lens thickness (LT) obtained with two A-mode ultrasounds (PalmScan A2000 and Eye Cubed) using an immersion technique. We compared the measurements with a two-sample t-test. Agreement between the two devices was assessed with Bland-Altman plots and 95% limits of agreement. 70 eyes of 70 patients were enrolled in this study. The measurements with the Eye Cubed of AL and ACD were shorter than the measurements taken by the PalmScan. The differences were not statistically significant regarding AL (p < 0.4) but significant regarding ACD (p < 0.001). The highest agreement between the two devices was obtained during LT measurement. The PalmScan measurements were shorter, but not statistically significantly (p < 0.2). The values of AL and LT, obtained with both devices are not identical, but within the limits of agreement. The agreement is not affected by the magnitude of the ocular dimensions (but only between range of 20 mm to 27 mm of AL and 3.5 mm to 5.7 mm of LT). A correction of about 0.5 D could be considered if an intraocular lens is being calculated. However due to the large variability of the results, the authors recommend discretion in using this conversion factor, and to adjust the power of the intraocular lenses based upon the personal experience of the surgeon.

  17. Investigating the Construct Measured by Banked Gap-Fill Items: Evidence from Eye-Tracking

    Science.gov (United States)

    McCray, Gareth; Brunfaut, Tineke

    2018-01-01

    This study investigates test-takers' processing while completing banked gap-fill tasks, designed to test reading proficiency, in order to test theoretically based expectations about the variation in cognitive processes of test-takers across levels of performance. Twenty-eight test-takers' eye traces on 24 banked gap-fill items (on six tasks) were…

  18. Phacoemulsificatıon in eyes wıth cataract and high myopia.

    Science.gov (United States)

    Cetinkaya, Servet; Acir, Nursen Oncel; Cetinkaya, Yasemin Fatma; Dadaci, Zeynep; Yener, Halil İbrahim; Saglam, Faik

    2015-01-01

    To evaluate the outcomes and complications following phacoemulsification surgery in eyes with cataract and high myopia. We retrospectively evaluated the data of 43 eyes of 28 consecutive patients (12 males, 16 females) with cataract and high myopia who had undergone phacoemulsification and intraocular lens (IOL) implantation. The mean [± standard deviation (range)] age of the patients was 59.20 ± 11.08 (39-77) years. The frequency of nuclear cataract was significantly higher than that of other cataract types (P=0.003). The mean axial length was 28.97 ± 1.99 (26-33) mm and the mean IOL power was 5.09 ± 4.78 (-3.0 to +14.0) diopters (D). The mean preoperative spherical equivalent (SE) was -16.48 ± 5.23 (-8.00 to -25.00) D and the mean postoperative SE was -1.46 ± 0.93 (0.00 to -3.00) D (P=0.00). The mean preoperative best-corrected visual acuity (BCVA) was 0.91 ± 0.37 (0.30 to -1.50) logMAR and the mean postoperative BCVA was 0.29 ± 0.25 (0.00-1.00) logMAR (P=0.00). Twenty-two eyes (51.2%) achieved the target postoperative refraction (±1.0 D). The eyes were divided into 3 groups according to the axial length. The mean biometric error was significantly higher in the group with the greatest axial length than in the other groups (P=0.007). Preoperative argon laser photocoagulation was performed in 7 eyes (16%) on account of retinal tears, retinal holes, or lattice degeneration. Postoperatively, retinal tears developed in 2 eyes (4%) and were treated with photocoagulation. One eye (2%) developed retinal detachment postoperatively, with the patient consequently referred for retinal surgery. Postoperatively, posterior capsule opacities developed in 11 eyes (25%), with all cases treated by laser capsulotomy. Good postoperative outcomes following phacoemulsification surgery were observed in patients with cataract and high myopia. However, clinicians should be aware of the risk of postoperative retinal tears and rhegmatogenous retinal detachment. Preoperative

  19. Effects of Punctal Occlusion on Clinical Signs and Symptoms and on Tear Cytokine Levels in Patients with Dry Eye.

    Science.gov (United States)

    Tong, Louis; Beuerman, Roger; Simonyi, Susan; Hollander, David A; Stern, Michael E

    2016-04-01

    To investigate changes in signs, symptoms, and tear cytokines following punctal plug occlusion in patients with dry eye. A single-center study was conducted at Singapore Eye Research Institute. Nonabsorbable punctal plugs were inserted in the lower punctum of both eyes in patients with moderate dry eye. Over 3 weeks, in the more severe eye, dry eye symptoms, fluorescein corneal staining, Schirmer I (without topical anesthesia) test, tear film breakup time (TFBUT), and safety were assessed. Cytokine and matrix metalloproteinase-9 (MMP-9) levels in tear samples were measured. Twenty-nine patients (mean age 49.8 years) with moderate dry eye were evaluated. At baseline, mean (standard deviation) global symptoms score was 53.8 (26.5), Schirmer I test score was 5.1 (2.8) mm, and TFBUT was 2.2 (0.6) seconds. After 3 weeks, punctal occlusion significantly reduced global irritation symptoms score (Pdry eye disease. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  20. Evaluating Eye Drop Instillation Technique and Its Determinants in Glaucoma Patients

    Directory of Open Access Journals (Sweden)

    Xinbo Gao

    2018-01-01

    Full Text Available Aim. To evaluate eye drop instillation technique and to explore its determinants in glaucoma patients. Methods. One hundred and thirteen patients diagnosed with glaucoma and self-administering topical antiglaucoma eye drops for at least 1 month were evaluated. All patients instilled artificial tear solution in one eye as they would do at home. The whole process was evaluated by two study staff. A comprehensive score system associated with eye drop instillation techniques was used to quantify the instillation technique and explore its determinants such as demographic and clinical characteristics. Results. Half of the patients (48.67% finished the administration of eye drop on first attempt.1.7 eye drops were squeezed out on average. 43 patients (37.17% got contact with ocular surface or adnexa. Only 19.7% patients had eye drop instillation techniques being defined as well. 11 patients (9.7% had prior instruction regarding using eye drops, while only 4 patients knew to occlude the tear duct by pressing the dacryocyst area. Older age and worse visual acuity were found to be independent risk factors for worse instillation technique. Conclusions. Eye drop instillation technique in glaucoma patients deserves great attention from eye care practitioners during their lifelong follow-up, especially those aged older and have worse visual acuity.

  1. Social Attention in the Two Species of Pan: Bonobos Make More Eye Contact than Chimpanzees.

    Directory of Open Access Journals (Sweden)

    Fumihiro Kano

    Full Text Available Humans' two closest primate living relatives, bonobos and chimpanzees, differ behaviorally, cognitively, and emotionally in several ways despite their general similarities. While bonobos show more affiliative behaviors towards conspecifics, chimpanzees display more overt and severe aggression against conspecifics. From a cognitive standpoint, bonobos perform better in social coordination, gaze-following and food-related cooperation, while chimpanzees excel in tasks requiring extractive foraging skills. We hypothesized that attention and motivation play an important role in shaping the species differences in behavior, cognition, and emotion. Thus, we predicted that bonobos would pay more attention to the other individuals' face and eyes, as those are related to social affiliation and social coordination, while chimpanzees would pay more attention to the action target objects, as they are related to foraging. Using eye-tracking we examined the bonobos' and chimpanzees' spontaneous scanning of pictures that included eyes, mouth, face, genitals, and action target objects of conspecifics. Although bonobos and chimpanzees viewed those elements overall similarly, bonobos viewed the face and eyes longer than chimpanzees, whereas chimpanzees viewed the other elements, the mouth, action target objects and genitals, longer than bonobos. In a discriminant analysis, the individual variation in viewing patterns robustly predicted the species of individuals, thus clearly demonstrating species-specific viewing patterns. We suggest that such attentional and motivational differences between bonobos and chimpanzees could have partly contributed to shaping the species-specific behaviors, cognition, and emotion of these species, even in a relatively short period of evolutionary time.

  2. Human eye colour and HERC2, OCA2 and MATP

    DEFF Research Database (Denmark)

    Mengel-From, Jonas; Børsting, Claus; Sanchez, Juan J.

    2010-01-01

    Prediction of human eye colour by forensic genetic methods is of great value in certain crime investigations. Strong associations between blue/brown eye colour and the SNP loci rs1129038 and rs12913832 in the HERC2 gene were recently described. Weaker associations between eye colour and other...... value of typing either the HERC2 SNPs rs1129038 and/or rs12913832 that are in strong linkage disequilibrium was observed when eye colour was divided into two groups, (1) blue, grey and green (light) and (2) brown and hazel (dark). Sequence variations in rs11636232 and rs7170852 in HERC2, rs1800407...... genetic markers also exist. In 395 randomly selected Danes, we investigated the predictive values of various combinations of SNP alleles in the HERC2, OCA2 and MATP (SLC45A2) genes and compared the results to the eye colours as they were described by the individuals themselves. The highest predictive...

  3. [Age factor in eye regeneration of the gastropod mollusk Achatina fulica].

    Science.gov (United States)

    Tartakovskaia, O S; Borisenko, S L; Zhukov, V V

    2003-01-01

    The dependence of the ability to regenerate the eye on the age of experimental animals was studied in the snail Achatina fulica. The degree of regeneration was estimated by light-microscopic and electrophysiological methods and by analyzing the motor response to visual stimuli. In older age groups, the number of regenerated eye-bearing tentacles decreased, whereas the period of regeneration increased. The regenerated eyes of the snails operated at the age of more than two months remained smaller than normal eyes even after six months. Regeneration of the distal part of the optic nerve was observed, and the regenerated eyes recovered the ability to respond to stimulation by light. In the electroretinogram, the responses of the regenerated eye, compared to the control, were characterised by a lower amplitude and longer repolarization and refractory periods. Manifestations of the motor response to visual stimuli in the young snails with regenerating eyes could be regarded as evidence for the recovery of connection between the organ of sight and the central ganglia.

  4. Characterization of new eye drops with choline salicylate and assessment of their irritancy by in vitro short time exposure tests.

    Science.gov (United States)

    Wroblewska, Katarzyna; Kucinska, Małgorzata; Murias, Marek; Lulek, Janina

    2015-09-01

    The aim of our study was to examine the irritation potential of new eye drops containing 2% choline salicylate (CS) as an active pharmaceutical ingredient (API) and various polymers increasing eye drop viscosity (hydroxyethylcellulose, hydroxypropyl methylcellulose, methylcellulose, polyvinyl alcohol, polyvinylpyrrolidone). The standard method for assessing the potential of irritating substances has been the Draize rabbit eye test. However the European Centre for Validation of Alternative Methods and the Coordinating Committee for Validation of Alternative Methods recommend, short time exposure (STE) in vitro tests as an alternative method for assessing eye irritation. The eye irritation potential was determined using cytotoxicity test methods for rabbit corneal cell line (SIRC) after 5 min exposure. The viability of cells was determined using two cytotoxicity assays: MTT and Neutral Red Uptake. According to the irritation rankings for the short time exposure test, all tested eye drops are classified as non-irritating (cell viability >70%).

  5. Juvenile eye growth, when completed?

    DEFF Research Database (Denmark)

    Fledelius, Hans C; Christensen, Anders S; Fledelius, Christian

    2014-01-01

    PURPOSE: To test Sorsby's classical statement of axial eye growth as completed at the age of 13 years, with a view also to differentiating between basic eye growth and juvenile elongation associated with eventual refractive change towards myopia. METHODS: (i) A total of 160 healthy eyes close...... about age 13 as general limit found support from the cross-sectional data, which suggested stable emmetropic eye size from about 11-12 years, with an average apparently outgrown male emmetropic value of 23.5 mm versus females' 22.9 mm. The longitudinal data, however, showed emmetropic growth also beyond...

  6. Photorefraction of the Eye

    Science.gov (United States)

    Colicchia, Giuseppe; Wiesner, Hartmut; Zollman, Dean

    2015-01-01

    Photorefraction is a method to easily estimate the refractive state of the eye. The principle of photorefraction involves projecting light into the eye during flash photography and then examining the paths of light that emerge from the pupil after scattering on the back portion of the interior of the eyeball (fundus). We will explain the optical…

  7. Functional magnetic resonance imaging of the frontal eye fields during saccadic eye movements

    International Nuclear Information System (INIS)

    Miki, Atsushi; Takagi, Mineo; Abe, Haruki; Nakajima, Takashi; Miyauchi, Satoru.

    1996-01-01

    We evaluated activity-induced signal intensity changes in the human cerebral cortex during horizontal saccadic eye movements using functional magnetic resonance imaging (fMRI) based on the blood-oxygenation-level-dependent (BOLD) contrast method. Compared with central fixation, significant signal increases were observed bilaterally in the middle frontal gyrus (Brodmann area 8) during saccadic conditions. The location of the activated area was consistent with that of previously reported frontal eye fields (FEF). These results suggest that fMRI has potential merit for the study of cortical control of eye movements in humans. (author)

  8. Cyclooxygenase-2 expression in the normal human eye and its expression pattern in selected eye tumours

    DEFF Research Database (Denmark)

    Wang, Jinmei; Wu, Yazhen; Heegaard, Steffen

    2011-01-01

    Purpose: Cyclooxygenase-2 (COX-2) is an enzyme involved in neoplastic processes. The purpose of the present study is to investigate COX-2 expression in the normal human eye and the expression pattern in selected eye tumours involving COX-2 expressing cells. Methods: Immunohistochemical staining...... using antibodies against COX-2 was performed on paraffin sections of normal human eyes and selected eye tumours arising from cells expressing COX-2. Results: Cyclooxygenase-2 expression was found in various structures of the normal eye. Abundant expression was seen in the cornea, iris, ciliary body...... and retina. The COX-2 expression was less in tumours deriving from the ciliary epithelium and also in retinoblastoma. Conclusion: Cyclooxygenase-2 is constitutively expressed in normal human eyes. The expression of COX-2 is much lower in selected eye tumours involving COX-2 expressing cells....

  9. Connecting eye to eye

    DEFF Research Database (Denmark)

    Dau, Susanne; Rask, Anders Bindslev

    2017-01-01

    Computer Supported Collaborative Learning (CSCL) is used a frame for supporting online and blended learning in educations. The online communication and collaboration are afforded by the social collaboration. However, the social collaboration is based on the establishment of direct eye contact...... (Khalid, Deska & Hugenberg, 2016), but direct eye contact is challenged by the position of the digital devices and thus CSCL. Lack of eye contact is the chief contributor to the negative effects of online disinhibition (Lapidot-Lefler & Barak, 2012) and the problem is the location of the web camera...... at the computer. Eye contact is challenged by the displacement between the senders´ and receivers´ focus on the screen picture and the camera's location at the top or bottom of screens on all digital devices. The aim of this paper is accordingly to investigate the influence of the displacement in eye contact...

  10. Quality indicators for eye bank.

    Science.gov (United States)

    Acharya, Manisha; Biswas, Saurabh; Das, Animesh; Mathur, Umang; Dave, Abhishek; Singh, Ashok; Dubey, Suneeta

    2018-03-01

    The aim of this study is to identify quality indicators of the eye bank and validate their effectivity. Adverse reaction rate, discard rate, protocol deviation rate, and compliance rate were defined as Quality Indicators of the eye bank. These were identified based on definition of quality that captures two dimensions - "result quality" and "process quality." The indicators were measured and tracked as part of quality assurance (QA) program of the eye bank. Regular audits were performed to validate alignment of standard operating procedures (SOP) with regulatory and surgeon acceptance standards and alignment of activities performed in the eye bank with the SOP. Prospective study of the indicators was performed by comparing their observed values over the period 2011-2016. Adverse reaction rate decreased more than 8-fold (from 0.61% to 0.07%), discard rate decreased and stabilized at 30%, protocol deviation rate decreased from 1.05% to 0.08%, and compliance rate reported by annual quality audits improved from 59% to 96% at the same time. In effect, adverse reaction rate, discard rate, and protocol deviation rate were leading indicators, and compliance rate was the trailing indicator. These indicators fulfill an important gap in available literature on QA in eye banking. There are two ways in which these findings can be meaningful. First, eye banks which are new to quality measurement can adopt these indicators. Second, eye banks which are already deeply engaged in quality improvement can test these indicators in their eye bank, thereby incorporating them widely and improving them over time.

  11. Teaching Idiomatic Expressions: A Comparison of Two Instructional Methods.

    Science.gov (United States)

    Rittenhouse, Robert K.; Kenyon, Patricia L.

    1990-01-01

    Twenty hearing-impaired adolescents were taught idiomatic expressions using captioned videotape presentations followed by classroom discussion, or by extended classroom discussions. Improvement in understanding idioms was significantly greater under the videotape method. (Author/JDD)

  12. How to ensure equitable access to eye health for children with disabilities

    Directory of Open Access Journals (Sweden)

    Hannah Kuper

    2016-07-01

    Full Text Available All children need access to good quality eye care, and this must include children with disabilities. Childhood disability is very common. The World Health Organization (WHO estimates that there are at least 93 million children with disabilities worldwide, which equates to one in twenty children.1 Childhood disability is particularly common in low- and middle-income countries.

  13. Retinal vessel caliber and myopic retinopathy: the blue mountains eye study.

    Science.gov (United States)

    Li, Haitao; Mitchell, Paul; Rochtchina, Elena; Burlutsky, George; Wong, Tien Y; Wang, Jie Jin

    2011-12-01

    To evaluate changes in the retinal vasculature in eyes with myopic retinopathy. Population-based, cross-sectional study. Emmetropic and myopic participants from the Blue Mountains Eye Study baseline survey were included in this study. Myopia was defined as a refractive error of less than -1.00 diopter. Myopic retinopathy was defined if either staphyloma, lacquer crack, Fuchs' spot or chorioretinal atrophy were present in myopic eyes. Retinal vascular caliber was measured from fundus photographs using standardized methods. The association of retinal vascular caliber with myopic retinopathy was assessed using generalized estimating equation models. A total of 2598 eyes of 1409 subjects were selected from 3654 baseline participants, with 2076 emmetropic eyes (normal controls), 486 myopic eyes without myopic retinopathy (myopic controls) and 36 myopic eyes with myopic retinopathy (cases). After adjusting for age, gender, height, body mass index and blood pressure, eyes with myopic retinopathy had significantly narrower mean arteriolar (166.6μm) and venular caliber (213.3μm), compared to normal (188.1μm and 226.9μm, respectively) or myopic control eyes (190.4μm and 227.0μm, respectively) (all P retinopathy and the two control groups remained significant after additional adjustment for refraction (all P retinopathy is associated with attenuation of retinal vessels.

  14. Eye Allergies

    Science.gov (United States)

    ... Español Eye Health / Eye Health A-Z Eye Allergies Sections What Are Eye Allergies? Eye Allergy Symptoms ... allergy diagnosis Eye allergy treatment What Are Eye Allergies? Leer en Español: ¿Qué son las alergias de ...

  15. Real Time Eye Detector with Cascaded Convolutional Neural Networks

    Directory of Open Access Journals (Sweden)

    Bin Li

    2018-01-01

    Full Text Available An accurate and efficient eye detector is essential for many computer vision applications. In this paper, we present an efficient method to evaluate the eye location from facial images. First, a group of candidate regions with regional extreme points is quickly proposed; then, a set of convolution neural networks (CNNs is adopted to determine the most likely eye region and classify the region as left or right eye; finally, the center of the eye is located with other CNNs. In the experiments using GI4E, BioID, and our datasets, our method attained a detection accuracy which is comparable to existing state-of-the-art methods; meanwhile, our method was faster and adaptable to variations of the images, including external light changes, facial occlusion, and changes in image modality.

  16. Communication Aid with Human Eyes Only

    Science.gov (United States)

    Arai, Kohei; Yajima, Kenro

    A communication aid with human eyes only is proposed. A set of candidate character is displayed onto computer screen of relatively small and light Head Mount Display: HMD that is mounted on glasses of which user wears on. When user looks at a candidate character with his/hers left eye while right eye picture is taken with small and light web camera that also is mounted on the glasses. The proposed system can selects 81 characters with two layers of 9 by 9 character candidate image. Other than these there is another selective image including control keys and frequently use of sentences. By using image matching between previously acquired template image for each candidate character and the currently acquired image, the proposed system realizes that which character in the candidates is selected. By using blinking and fix one's eye on combine together, the proposed system recognizes that user determines the selected key from the candidates. The blinking detection method employs a morphologic filter to avoid misunderstanding of dark eye detection due to eyebrows and shadows. Thus user can input sentences. User also may edit the sentences and then the sentences are read with Text to Speech: TTS software tool. Thus the system allows support conversations between handicapped and disabled persons without voice and the others peoples because only the function required for conversation is human eyes. Also the proposed system can be used as an input system for wearable computing systems. Test results by the 6 different able persons show that the proposed system does work with acceptable speed, around 1.5 second / character.

  17. An improved likelihood model for eye tracking

    DEFF Research Database (Denmark)

    Hammoud, Riad I.; Hansen, Dan Witzner

    2007-01-01

    While existing eye detection and tracking algorithms can work reasonably well in a controlled environment, they tend to perform poorly under real world imaging conditions where the lighting produces shadows and the person's eyes can be occluded by e.g. glasses or makeup. As a result, pixel clusters...... associated with the eyes tend to be grouped together with background-features. This problem occurs both for eye detection and eye tracking. Problems that especially plague eye tracking include head movement, eye blinking and light changes, all of which can cause the eyes to suddenly disappear. The usual...... approach in such cases is to abandon the tracking routine and re-initialize eye detection. Of course this may be a difficult process due to missed data problem. Accordingly, what is needed is an efficient method of reliably tracking a person's eyes between successively produced video image frames, even...

  18. Maxwellian Eye Fixation during Natural Scene Perception

    Directory of Open Access Journals (Sweden)

    Jean Duchesne

    2012-01-01

    Full Text Available When we explore a visual scene, our eyes make saccades to jump rapidly from one area to another and fixate regions of interest to extract useful information. While the role of fixation eye movements in vision has been widely studied, their random nature has been a hitherto neglected issue. Here we conducted two experiments to examine the Maxwellian nature of eye movements during fixation. In Experiment 1, eight participants were asked to perform free viewing of natural scenes displayed on a computer screen while their eye movements were recorded. For each participant, the probability density function (PDF of eye movement amplitude during fixation obeyed the law established by Maxwell for describing molecule velocity in gas. Only the mean amplitude of eye movements varied with expertise, which was lower in experts than novice participants. In Experiment 2, two participants underwent fixed time, free viewing of natural scenes and of their scrambled version while their eye movements were recorded. Again, the PDF of eye movement amplitude during fixation obeyed Maxwell’s law for each participant and for each scene condition (normal or scrambled. The results suggest that eye fixation during natural scene perception describes a random motion regardless of top-down or of bottom-up processes.

  19. Maxwellian Eye Fixation during Natural Scene Perception

    Science.gov (United States)

    Duchesne, Jean; Bouvier, Vincent; Guillemé, Julien; Coubard, Olivier A.

    2012-01-01

    When we explore a visual scene, our eyes make saccades to jump rapidly from one area to another and fixate regions of interest to extract useful information. While the role of fixation eye movements in vision has been widely studied, their random nature has been a hitherto neglected issue. Here we conducted two experiments to examine the Maxwellian nature of eye movements during fixation. In Experiment 1, eight participants were asked to perform free viewing of natural scenes displayed on a computer screen while their eye movements were recorded. For each participant, the probability density function (PDF) of eye movement amplitude during fixation obeyed the law established by Maxwell for describing molecule velocity in gas. Only the mean amplitude of eye movements varied with expertise, which was lower in experts than novice participants. In Experiment 2, two participants underwent fixed time, free viewing of natural scenes and of their scrambled version while their eye movements were recorded. Again, the PDF of eye movement amplitude during fixation obeyed Maxwell's law for each participant and for each scene condition (normal or scrambled). The results suggest that eye fixation during natural scene perception describes a random motion regardless of top-down or of bottom-up processes. PMID:23226987

  20. Application of hydrochloric cyclopentolate eye drops in the mydriasis test and optometry for children with hyperopia

    Directory of Open Access Journals (Sweden)

    Hong-Ping Yin

    2016-02-01

    Full Text Available AIM:To observe and study the comprehensive application effect of hydrochloric cyclopentolate eye drops in the mydriasis test and optometry for children with hyperopia.METHODS:Eighty-four children with hyperopia who were intervened with mydriasis test and optometry in our hospital from February 2014 to March 2015 were selected as the research object,and they were intervened with mydriasis test and optometry by tropicamide or hydrochloric cyclopentolate eye drops. The diopter, pupil diameter and residual regulation before administration and at different time after administration of the two methods were compared,and the detected results of the two groups with different severity degree were compared too.RESULTS:The diopter, pupil diameter and residual regulation before administration of the two eye drops had no significant differences(all P>0.05,while the residual regulation after using hydrochloric cyclopentolate eye drops at 20, 40, 60min and 24h were all smaller than those after using tropicamide(all PP>0.05. The pupil diameter of the two groups at 48h after administration both had no significant differences to those before administration(all P>0.05.CONCLUSION:The comprehensive application effect of hydrochloric cyclopentolate eye drops in the mydriasis test and optometry of children with hyperopia is better,and its paralysis effect for ciliaris is obvious.

  1. Dry Eye

    Science.gov (United States)

    ... Eye » Facts About Dry Eye Listen Facts About Dry Eye Fact Sheet Blurb The National Eye Institute (NEI) ... and their families search for general information about dry eye. An eye care professional who has examined the ...

  2. Attentional bias to betel quid cues: An eye tracking study.

    Science.gov (United States)

    Shen, Bin; Chiu, Meng-Chun; Li, Shuo-Heng; Huang, Guo-Joe; Liu, Ling-Jun; Ho, Ming-Chou

    2016-09-01

    The World Health Organization regards betel quid as a human carcinogen, and DSM-IV and ICD-10 dependence symptoms may develop with heavy use. This study, conducted in central Taiwan, investigated whether betel quid chewers can exhibit overt orienting to selectively respond to the betel quid cues. Twenty-four male chewers' and 23 male nonchewers' eye movements to betel-quid-related pictures and matched pictures were assessed during a visual probe task. The eye movement index showed that betel quid chewers were more likely to initially direct their gaze to the betel quid cues, t(23) = 3.70, p betel quid chewers' attentional bias. The results demonstrated that the betel quid chewers (but not the nonchewers) were more likely to initially direct their gaze to the betel quid cues, and spent more time and were more fixated on them. These findings suggested that when attention is directly measured through the eye tracking technique, this methodology may be more sensitive to detecting attentional biases in betel quid chewers. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  3. Multi-resolution voxel phantom modeling: a high-resolution eye model for computational dosimetry.

    Science.gov (United States)

    Caracappa, Peter F; Rhodes, Ashley; Fiedler, Derek

    2014-09-21

    Voxel models of the human body are commonly used for simulating radiation dose with a Monte Carlo radiation transport code. Due to memory limitations, the voxel resolution of these computational phantoms is typically too large to accurately represent the dimensions of small features such as the eye. Recently reduced recommended dose limits to the lens of the eye, which is a radiosensitive tissue with a significant concern for cataract formation, has lent increased importance to understanding the dose to this tissue. A high-resolution eye model is constructed using physiological data for the dimensions of radiosensitive tissues, and combined with an existing set of whole-body models to form a multi-resolution voxel phantom, which is used with the MCNPX code to calculate radiation dose from various exposure types. This phantom provides an accurate representation of the radiation transport through the structures of the eye. Two alternate methods of including a high-resolution eye model within an existing whole-body model are developed. The accuracy and performance of each method is compared against existing computational phantoms.

  4. Assessment of Corneal Epithelial Thickness in Asymmetric Keratoconic Eyes and Normal Eyes Using Fourier Domain Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    S. Catalan

    2016-01-01

    Full Text Available Purpose. To compare the characteristics of asymmetric keratoconic eyes and normal eyes by Fourier domain optical coherence tomography (OCT corneal mapping. Methods. Retrospective corneal and epithelial thickness OCT data for 74 patients were compared in three groups of eyes: keratoconic (n=22 and normal fellow eyes (n=22 in patients with asymmetric keratoconus and normal eyes (n=104 in healthy subjects. Areas under the curve (AUC of receiver operator characteristic (ROC curves for each variable were compared across groups to indicate their discrimination capacity. Results. Three variables were found to differ significantly between fellow eyes and normal eyes (all p<0.05: minimum corneal thickness, thinnest corneal point, and central corneal thickness. These variables combined showed a high discrimination power to differentiate fellow eyes from normal eyes indicated by an AUC of 0.840 (95% CI: 0.762–0.918. Conclusions. Our findings indicate that topographically normal fellow eyes in patients with very asymmetric keratoconus differ from the eyes of healthy individuals in terms of their corneal epithelial and pachymetry maps. This type of information could be useful for an early diagnosis of keratoconus in topographically normal eyes.

  5. A method to reduce patient's eye lens dose in neuro-interventional radiology procedures

    International Nuclear Information System (INIS)

    Safari, M.J.; Wong, J.H.D.; Kadir, K.A.A.; Sani, F.M.; Ng, K.H.

    2016-01-01

    Complex and prolonged neuro-interventional radiology procedures using the biplane angiography system increase the patient's risk of radiation-induced cataract. Physical collimation is the most effective way of reducing the radiation dose to the patient's eye lens, but in instances where collimation is not possible, an attenuator may be useful in protecting the eyes. In this study, an eye lens protector was designed and fabricated to reduce the radiation dose to the patients’ eye lens during neuro-interventional procedures. The eye protector was characterised before being tested on its effectiveness in a simulated aneurysm procedure on an anthropomorphic phantom. Effects on the automatic dose rate control (ADRC) and image quality are also evaluated. The eye protector reduced the radiation dose by up to 62.1% at the eye lens. The eye protector is faintly visible in the fluoroscopy images and increased the tube current by a maximum of 3.7%. It is completely invisible in the acquisition mode and does not interfere with the clinical procedure. The eye protector placed within the radiation field of view was able to reduce the radiation dose to the eye lens by direct radiation beam of the lateral x-ray tube with minimal effect on the ADRC system. - Highlights: • The eye protector can considerably reduce the patient's eye lens dose during neuro-interventional procedures. • This protector does not significantly perturb the fluoroscopy image and was completely invisible on the acquisition image due to image subtraction. • The eye protector does not significantly change the exposure parameters (kV and mAs).

  6. [Clinical characteristics of short tear film breakup time (BUT) -type dry eye].

    Science.gov (United States)

    Yamamoto, Yuji; Yokoi, Norihiko; Higashihara, Hisayo; Inagaki, Kayoko; Sonomura, Yukiko; Komuro, Aoi; Kinoshita, Shigeru

    2012-12-01

    To evaluate the clinical characteristics and management of short tear film breakup time (BUT) -type dry eye. Clinical background and post-treatment changes of symptoms in 77 patients with short BUT -type dry eye were investigated. Treatment consisted of artificial-tear eye-drop instillation and, if necessary, the addition of a low-density-level steroid, hyaluronic acid, a low-density-level cyclopentolate prepared by ourselves and punctal plugs inserted into the upper and lower lacrimal puncta. There were three times more women than men among the patients, and the peak age of occurrence was in the twenties in the men and in the sixties in the women. Our findings show that visual display terminal (VDT) work, contact lens (CL) wear, and changes in the sex hormones may initiate subjective symptoms. Some patients had simultaneous conjunctivochalasis, allergic conjunctivitis, and meibomian gland dysfunction. Nineteen patients (24.7%) were effectively treated with eye-drop instillation alone. Thirty-seven patients (48.1%) required punctal-plug insertion, which was completely effective in only 8 of them (21.6%). Mainly young men and menopausal women contract short BUT -type dry eye. Changes in sex hormones, VDT work and CL wear may be causal, and the disease cannot be controlled by eyedrop and punctal-plug treatment alone.

  7. Dry eye syndrome in thyroid-associated ophthalmopathy

    Directory of Open Access Journals (Sweden)

    A. F. Brovkina

    2015-01-01

    Full Text Available Purpose: The pathogenesis of keratoconjunctivitis sicca in patients with thyroid eye disease is presented. The influence of therapy by a HYLO-PARIN® on a condition of a tear film in patients with various forms of thyroid eye disease is assessed. Methods: 34 eyes (17 patients with thyroid eye disease were investigated. Dry eye evaluations included Shirmer and Jhones testing, tear film break-up time, corneal fluorescein staining. Patients were treated with HYLOPARIN ® (Ursapharm, Germany.Results: Study showed that HYLO-PARIN® resulted in marked improvement as assessed by subjective complaints, Schirmer’s test, tear film break-up test.Conclusion: HYLO-PARIN® provided relief from the signsand symptoms of dry eye syndrome at patients with various forms of thyroid eye disease.

  8. Dry eye syndrome in thyroid-associated ophthalmopathy

    Directory of Open Access Journals (Sweden)

    A. F. Brovkina

    2014-01-01

    Full Text Available Purpose: The pathogenesis of keratoconjunctivitis sicca in patients with thyroid eye disease is presented. The influence of therapy by a HYLO-PARIN® on a condition of a tear film in patients with various forms of thyroid eye disease is assessed. Methods: 34 eyes (17 patients with thyroid eye disease were investigated. Dry eye evaluations included Shirmer and Jhones testing, tear film break-up time, corneal fluorescein staining. Patients were treated with HYLOPARIN ® (Ursapharm, Germany.Results: Study showed that HYLO-PARIN® resulted in marked improvement as assessed by subjective complaints, Schirmer’s test, tear film break-up test.Conclusion: HYLO-PARIN® provided relief from the signsand symptoms of dry eye syndrome at patients with various forms of thyroid eye disease.

  9. Iris coloboma in one eye and pigment dispersion syndrome in the fellow eye.

    Science.gov (United States)

    Galvis, Virgilio; Tello, Alejandro; Valarezo, Paul; Prada, Angélica M

    2013-05-22

    We report a case of a 43-year-old patient with coloboma of the iris, zonule, ciliary body, choroid and retina in the right eye and pigment dispersion syndrome in the left eye. Considering the hypothesis of the pigment dispersion syndrome pathogenesis in which a difference of pressures in the anterior and posterior chambers creates a posterior convexity of the iris leading to reverse pupillary block, iris touch and consequently causing pigment dispersion, we suggest that the presence of an iris coloboma, by equalising the pressures in the two chambers, prevented the onset of syndrome in that eye.

  10. Are Eyes a Mirror of the Soul? What Eye Wrinkles Reveal about a Horse's Emotional State.

    Directory of Open Access Journals (Sweden)

    Sara Hintze

    Full Text Available Finding valid indicators of emotional states is one of the biggest challenges in animal welfare science. Here, we investigated in horses whether variation in the expression of eye wrinkles caused by contraction of the inner eyebrow raiser reflects emotional valence. By confronting horses with positive and negative conditions, we aimed to induce positive and negative emotional states, hypothesising that positive emotions would reduce whereas negative emotions would increase eye wrinkle expression. Sixteen horses were individually exposed in a balanced order to two positive (grooming, food anticipation and two negative conditions (food competition, waving a plastic bag. Each condition lasted for 60 seconds and was preceded by a 60 second control phase. Throughout both phases, pictures of the eyes were taken, and for each horse four pictures per condition and phase were randomly selected. Pictures were scored in random order and by two experimenters blind to condition and phase for six outcome measures: qualitative impression, eyelid shape, markedness of the wrinkles, presence of eye white, number of wrinkles, and the angle between the line through the eyeball and the highest wrinkle. The angle decreased during grooming and increased during food competition compared to control phases, whereas the two phases did not differ during food anticipation and the plastic bag condition. No effects on the other outcome measures were detected. Taken together, we have defined a set of measures to assess eye wrinkle expression reliably, of which one measure was affected by the conditions the horses were exposed to. Variation in eye wrinkle expression might provide valuable information on horse welfare but further validation of specific measures across different conditions is needed.

  11. Determination of positions of optical elements of the human eye

    International Nuclear Information System (INIS)

    Galetskii, S O; Cherezova, T Yu

    2009-01-01

    An original method for noninvasive determining the positions of elements of intraocular optics is proposed. The analytic dependence of the measurement error on the optical-scheme parameters and the restriction in distance from the element being measured are determined within the framework of the method proposed. It is shown that the method can be efficiently used for determining the position of elements in the classical Gullstrand eye model and personalised eye models. The positions of six optical surfaces of the Gullstrand eye model and four optical surfaces of the personalised eye model can be determined with an error of less than 0.25 mm. (human eye optics)

  12. Ecomorphology of the eyes and skull in zooplanktivorous labrid fishes

    Science.gov (United States)

    Schmitz, L.; Wainwright, P. C.

    2011-06-01

    Zooplanktivory is one of the most distinct trophic niches in coral reef fishes, and a number of skull traits are widely recognized as being adaptations for feeding in midwater on small planktonic prey. Previous studies have concluded that zooplanktivores have larger eyes for sharper visual acuity, reduced mouth structures to match small prey sizes, and longer gill rakers to help retain captured prey. We tested these three traditional hypotheses plus two novel adaptive hypotheses in labrids, a clade of very diverse coral reef fishes that show multiple independent evolutionary origins of zooplanktivory. Using phylogenetic comparative methods with a data set from 21 species, we failed to find larger eyes in three independent transitions to zooplanktivory. Instead, an impression of large eyes may be caused by a size reduction of the anterior facial region. However, two zooplanktivores ( Clepticus parrae and Halichoeres pictus) possess several features interpreted as adaptations to zooplankton feeding, namely large lens diameters relative to eye axial length, round pupil shape, and long gill rakers. The third zooplanktivore in our analysis, Cirrhilabrus solorensis, lacks all above features. It remains unclear whether Cirrhilabrus shows optical specializations for capturing planktonic prey. Our results support the prediction that increased visual acuity is adaptive for zooplanktivory, but in labrids increases in eye size are apparently not part of the evolutionary response.

  13. Serum components and clinical efficacies of autologous serum eye drops in dry eye patients with active and inactive Sjogren syndrome.

    Science.gov (United States)

    Ma, I-Hsin; Chen, Lily Wei; Tu, Wen-Hui; Lu, Chia-Ju; Huang, Chien-Jung; Chen, Wei-Li

    2017-01-01

    Autologous serum eye drops are considered safe and efficient for the treatment of various ocular surface disorders, including dry eye diseases (DED) caused by the primary and secondary Sjogren syndrome (SS). However, the serum components in patients of SS may be different from those of normal patients and can thus lead to unpredictable therapeutic effects. This study divided the SS patients into active and inactive types based on the erythrocyte sedimentation rate and the presence or absence of active rheumatoid arthritis. We compared the serum components of these two groups with standard and multiplex enzyme linked immunosorbent assay arrays and predicted the therapeutic effects of topical autologous serum for the treatment of DED with ocular surface disease index (OSDI) and Oxford Schema scale (OSS). Hyaluronic acid and transforming growth factor b1 levels were significantly higher in the active SS group compared to the inactive SS group ( P Sjogren dry eye patients into active and inactive groups may appear as a reasonable method to predict the quality of autologous serum eye drops, but there seems to be no significant predictability to the therapeutic effects.

  14. Tear proteomic analysis of patients with type 2 diabetes and dry eye syndrome by two-dimensional nano-liquid chromatography coupled with tandem mass spectrometry.

    Science.gov (United States)

    Li, Bing; Sheng, Minjie; Xie, Liqi; Liu, Feng; Yan, Guoquan; Wang, Weifang; Lin, Anjuan; Zhao, Fei; Chen, Yihui

    2014-01-09

    Diabetes mellitus has been shown to be associated with and complicated by dry eye syndrome. We sought to examine and compare the tear film proteome of type 2 diabetic patients with or without dry eye syndrome and normal subjects using two-dimensional nano-liquid chromatography coupled with tandem mass spectrometry (MS)-based proteomics. Tears were collected from eight type 2 diabetes patients with dry eye syndrome, eight type 2 diabetes patients without dry eye syndrome, and eight normal subjects. Tear breakup time (BUT) was determined, and tear proteins were prepared and analyzed using two-dimensional strong cation-exchange/reversed-phase nano-scale liquid chromatography MS. All MS/MS spectra were identified by using SEQUEST against the human International Protein Index (IPI) database and the relative abundance of individual proteins was assessed by spectral counting. Tear BUT was significantly lower in patients with diabetes and dry eye syndrome than in patients with diabetes only and normal subjects. Analysis of spectral counts of tear proteins showed that, compared to healthy controls, patients with diabetes and dry eye syndrome had increased expression of apoptosis-related proteins, like annexin A1, and immunity- and inflammation-related proteins, including neutrophil elastase 2 and clusterin, and glycometabolism-related proteins, like apolipoprotein A-II. Dry eye syndrome in diabetic patients is associated with aberrant expression of tear proteins, and the findings could lead to identification of novel pathways for therapeutic targeting and new diagnostic markers.

  15. Keep an Eye on Your Eyes: Technologies for Protecting Vision

    Science.gov (United States)

    ... disease,” Miller says. “With current technology, thousands of cells must die before it’s detected.” His team’s new method would allow eye doctors to see the damage earlier. In glaucoma, ...

  16. Predictive factors for final outcome of severely traumatized eyes with no light perception

    Directory of Open Access Journals (Sweden)

    Agrawal Rupesh

    2012-06-01

    Full Text Available Abstract Background An eye injury that causes no light perception (NLP typically carries an unfavorable prognosis, and NLP because of trauma is a common indication for enucleation. With advances in vitreoretinal surgical techniques, however, the indication for enucleation is no longer determined by posttrauma NLP vision alone. There are limited studies in the literature to analyse the outcome of NLP eyes following open globe injury. The current study was aimed to evaluate the outcome of surgical repair of severely traumatized eyes with no light perception vision as preoperative visual acuity. Secondary objective was to possibly predict the factors affecting the final vision outcome in this eyes. Methods Retrospective case analysis of patients with surgical repair of open globe injury over last ten years at a tertiary referral eye care centre in Singapore. Results Out of one hundred and seventy two eyes with open globe injury 27 (15.7% eyes had no light perception (NLP. After surgical repair, final visual acuity remained NLP in 18 (66.7% eyes. Final vision improved to Light perception/ Hand movement (LP/HM in 2(7.4% eyes, 1/200 to 19/200(11.1% in 3 eyes and 20/50-20/200(14.8% in 4 eyes. The median follow up was 18.9 months (range: 4–60 months. The factors contributing to poor postoperative outcome were presence of RAPD (p = 0.014, wound extending into zone III (p = 0.023 and associated vitreoretinal trauma (p = 0.008. Conclusions One third of eyes had ambulatory vision or better though two third of eyes still remained NLP. Pre-operative visual acuity of NLP should not be an indication for primary enucleation or evisceration for severely traumatized eyes. Presence of afferent papillary defect, wound extending posterior to rectus insertion and associated vitreoretinal trauma can adversely affect the outcome in severely traumatized eyes with NLP. Timely intervention and state of art surgery may restore useful vision in severely

  17. Analysis of Eye Care Services in Yemen

    OpenAIRE

    Saleh A. Al-Akily; Mutahar Y. Al-Shaer; Mahfouth A. Bamashmus; Abdulmoghni O. Al-Barrag; Tawfik K. Alkhatib; Hisham A. Al-Akhlee

    2017-01-01

    Purpose: The objective of this study was to undertake an analysis of the eye care services situation in Yemen and to assess ophthalmic human resources, eye units’ ownership and ophthalmic equipments. Methods: Eye care providers were surveyed by a standardized questionnaire which was sent to the 184 eye units in governmental, university, military, private and charity clinics and hospitals in Yemen and covered the period between 01 January to 31 December 2012. The questionnaire determined l...

  18. Routine monitoring of eye dose; and reply

    Energy Technology Data Exchange (ETDEWEB)

    Palmer, K; Jeans, S P; Faulkner, K; Bardsley, R A; Love, H G

    1985-12-01

    This letter briefly reports the assessment at Papworth Hospital of the feasibility of monitoring eye doses of staff using a film badge worn on the shoulder in addition to the badge worn under the lead apron. For three consecutive months hand and eye (forehead) dose were monitored using TLDs, while shoulder and body dose, recorded under the lead apron, were measured with film badges. For the four doctors monitored, (two radiologists and two cardiologists) the shoulder badge somewhat overestimated the eye dose. In the case of nurses, the dose recorded by the shoulder badge was of a similar order to the TLD-recorded eye dose. The reply from the Christie Hospital at Manchester comments on the use of the shoulder badge and contends that the use of forehead dosemeters to measure eye dose is to be preferred whenever possible.

  19. Eye movement identification based on accumulated time feature

    Science.gov (United States)

    Guo, Baobao; Wu, Qiang; Sun, Jiande; Yan, Hua

    2017-06-01

    Eye movement is a new kind of feature for biometrical recognition, it has many advantages compared with other features such as fingerprint, face, and iris. It is not only a sort of static characteristics, but also a combination of brain activity and muscle behavior, which makes it effective to prevent spoofing attack. In addition, eye movements can be incorporated with faces, iris and other features recorded from the face region into multimode systems. In this paper, we do an exploring study on eye movement identification based on the eye movement datasets provided by Komogortsev et al. in 2011 with different classification methods. The time of saccade and fixation are extracted from the eye movement data as the eye movement features. Furthermore, the performance analysis was conducted on different classification methods such as the BP, RBF, ELMAN and SVM in order to provide a reference to the future research in this field.

  20. Eye Movements in Darkness Modulate Self-Motion Perception.

    Science.gov (United States)

    Clemens, Ivar Adrianus H; Selen, Luc P J; Pomante, Antonella; MacNeilage, Paul R; Medendorp, W Pieter

    2017-01-01

    During self-motion, humans typically move the eyes to maintain fixation on the stationary environment around them. These eye movements could in principle be used to estimate self-motion, but their impact on perception is unknown. We had participants judge self-motion during different eye-movement conditions in the absence of full-field optic flow. In a two-alternative forced choice task, participants indicated whether the second of two successive passive lateral whole-body translations was longer or shorter than the first. This task was used in two experiments. In the first ( n = 8), eye movements were constrained differently in the two translation intervals by presenting either a world-fixed or body-fixed fixation point or no fixation point at all (allowing free gaze). Results show that perceived translations were shorter with a body-fixed than a world-fixed fixation point. A linear model indicated that eye-movement signals received a weight of ∼25% for the self-motion percept. This model was independently validated in the trials without a fixation point (free gaze). In the second experiment ( n = 10), gaze was free during both translation intervals. Results show that the translation with the larger eye-movement excursion was judged more often to be larger than chance, based on an oculomotor choice probability analysis. We conclude that eye-movement signals influence self-motion perception, even in the absence of visual stimulation.

  1. Template aging in eye movement-driven biometrics

    Science.gov (United States)

    Komogortsev, Oleg V.; Holland, Corey D.; Karpov, Alex

    2014-05-01

    This paper presents a template aging study of eye movement biometrics, considering three distinct biometric techniques on multiple stimuli and eye tracking systems. Short-to-midterm aging effects are examined over two-weeks, on a highresolution eye tracking system, and seven-months, on a low-resolution eye tracking system. We find that, in all cases, aging effects are evident as early as two weeks after initial template collection, with an average 28% (±19%) increase in equal error rates and 34% (±12%) reduction in rank-1 identification rates. At seven months, we observe an average 18% (±8%) increase in equal error rates and 44% (±20%) reduction in rank-1 identification rates. The comparative results at two-weeks and seven-months suggests that there is little difference in aging effects between the two intervals; however, whether the rate of decay increases more drastically in the long-term remains to be seen.

  2. Comparison of efficacy, safety, and predictability of laser in situ keratomileusis using two laser suites

    Directory of Open Access Journals (Sweden)

    Meidani A

    2016-08-01

    Full Text Available Alexandra Meidani,1–3 Chara Tzavara3 1Hypervision Laser Centre, 2Eye Day Clinic, 3Department of Hygiene, University of Athens Medical School, Centre for Health Services Research, Epidemiology and Medical Statistics, Athens, Greece Purpose: The main aim of this study was to compare the efficacy, safety, and predictability of femtosecond laser-assisted in situ keratomileusis performed by two different laser suites in the treatment of myopia for up to 6 months.Methods: In this two-site retrospective nonrandomized study, myopic eyes that underwent laser-assisted in situ keratomileusis using IntraLase FS 60 kHz formed group 1 and those using WaveLight FS200 femtosecond laser system formed group 2. Ablation was performed with Visx Star S4 IR and WaveLight EX500 Excimer lasers, respectively, in groups 1 and 2. Both groups were well matched for age, sex, and mean level of preoperative refractive spherical equivalent (MRSE. Uncorrected distance visual acuity, corrected distance visual acuity, and MRSE were evaluated preoperatively and at 1 week, 1 month, and 6 months after treatment.Results: Fifty-six eyes of 28 patients were included in the study. At 6-month follow-up postop, 78.6% of eyes in group 1 and 92.8% of eyes in group 2 achieved an uncorrected distance visual acuity of 20/20 or better (P=0.252. 35.7% and 50% in group 1 and group 2, respectively, gained one line (P=0.179. No eye lost lines of corrected distance visual acuity. Twenty-five eyes in group 1 (92.7% and 27 eyes in group 2 (96.3% had MRSE within ±0.5 D in the 6-month follow-up (P>0.999. The mean efficacy index at 6 months was similar in group 1 and group 2 (mean 1.10±0.12 [standard deviation] vs 1.10±0.1 (P=0.799. The mean safety index was similar in group 1 and group 2 (mean 1.10±0.10 [standard deviation] vs 1.10±0.09 (P=0.407.Conclusion: The outcomes were excellent between the two laser suites. There were no significant differences at 6-month follow-up postop between the two

  3. A novel method for measuring anterior segment area of the eye on ultrasound biomicroscopic images using photoshop.

    Science.gov (United States)

    Wang, Zhonghao; Liang, Xuanwei; Wu, Ziqiang; Lin, Jialiu; Huang, Jingjing

    2015-01-01

    To describe a novel method for quantitative measurement of area parameters in ocular anterior segment ultrasound biomicroscopy (UBM) images using Photoshop software and to assess its intraobserver and interobserver reproducibility. Twenty healthy volunteers with wide angles and twenty patients with narrow or closed angles were consecutively recruited. UBM images were obtained and analyzed using Photoshop software by two physicians with different-level training on two occasions. Borders of anterior segment structures including cornea, iris, lens, and zonules in the UBM image were semi-automatically defined by the Magnetic Lasso Tool in the Photoshop software according to the pixel contrast and modified by the observers. Anterior chamber area (ACA), posterior chamber area (PCA), iris cross-section area (ICA) and angle recess area (ARA) were drawn and measured. The intraobserver and interobserver reproducibilities of the anterior segment area parameters and scleral spur location were assessed by limits of agreement, coefficient of variation (CV), and intraclass correlation coefficient (ICC). All of the parameters were successfully measured by Photoshop. The intraobserver and interobserver reproducibilities of ACA, PCA, and ICA were good, with no more than 5% CV and more than 0.95 ICC, while the CVs of ARA were within 20%. The intraobserver and interobserver reproducibilities for defining the spur location were more than 0.97 ICCs. Although the operating times for both observers were less than 3 minutes per image, there was significant difference in the measuring time between two observers with different levels of training (pPhotoshop showed good intraobserver and interobserver reproducibilties. The methodology was easy to adopt and effective in measuring.

  4. Depression screening among older adults attending low-vision rehabilitation and eye-care services: Characteristics of those who screen positive and client acceptability of screening.

    Science.gov (United States)

    Holloway, Edith E; Sturrock, Bonnie A; Lamoureux, Ecosse L; Keeffe, Jill E; Rees, Gwyneth

    2015-12-01

    To investigate characteristics associated with screening positive for depressive symptoms among older adults accessing low-vision rehabilitation and eye-care services and to determine client acceptability of depression screening using the Patient Health Questionnaire-2 (PHQ-2) in these settings. One-hundred and twenty-four older adults (mean = 77.02 years, SD = 9.12) attending low-vision rehabilitation and eye-care services across Australia were screened for depression and invited to complete a telephone-administered questionnaire to determine characteristics associated with depressive symptoms and client acceptability of screening in these settings. Thirty-seven per cent (n = 46/124) of participants screened positive for depressive symptoms, and the majority considered the new depression screening method to be a 'good idea' in vision services (85%). Severe vision loss (<6/60 in the better eye) was associated with an increased odds of screening positive for depressive symptoms (odds ratio 2.37; 95% confidence interval 1.08-6.70) even after adjusting for potential confounders. Participants who screened positive had a preference for 'talking' therapy or a combination of medication and 'talking therapy' delivered within their own home (73%) or via telephone (67%). The PHQ-2 appears to be an acceptable method for depression screening in eye-care settings among older adults. Targeted interventions that incorporate home-based or telephone delivered therapy sessions may improve outcomes for depression in this group. © 2014 ACOTA.

  5. Eye dosimetry and protective eye wear for interventional clinicians

    International Nuclear Information System (INIS)

    Martin, C.J.; Magee, J.S.; Sandblom; Almen, A.; Lundh, C.

    2015-01-01

    Doses to the eyes of interventional clinicians can exceed 20 mSv. Various protective devices can afford protection to the eyes with the final barrier being protective eye wear. The protection provided by lead glasses is difficult to quantify, and the majority of dosimeters are not designed to be worn under lead glasses. This study has measured dose reduction factors (DRFs) equal to the ratio of the dose with no protection, divided by that when lead glasses are worn. Glasses have been tested in X-ray fields using anthropomorphic phantoms to simulate the patient and clinician. DRFs for X-rays incident from the front vary from 5.2 to 7.6, while values for orientations reminiscent of clinical practice are between 1.4 and 5.2. Results suggest that a DRF of two is a conservative factor that could be applied to personal dosimeter measurements to account for the dose reduction provided by most types of lead glasses. (authors)

  6. Knowledge, Attitude, and Perception of Barriers for Eye Care among Diabetic Persons Registered at Employee Health Department of a Tertiary Eye Hospital of Central Saudi Arabia.

    Science.gov (United States)

    Al-Alawi, Abeer; Al-Hassan, Arif; Chauhan, Deepti; Al-Futais, Muneera; Khandekar, Rajiv

    2016-01-01

    To evaluate the level of knowledge, attitudes, and barriers to diabetic retinopathy (DR) screening among diabetic healthcare staff at a tertiary eye hospital in central Saudi Arabia. This was a descriptive survey using a closed-ended questionnaire. A. 5-grade. Likert scale was used for responses to each question. Data were collected on patient demographics and the status of diabetes. Survey responses related to knowledge, attitude, and barriers were grouped. The study sample was comprised of 45 diabetics employed at the hospital. The mean age was 49 ± 11 years and 33 diabetics were males. One-third of the study population was referred to the eye clinic for DR screening. DR screening was performed in 25% of diabetics over the previous year. Twenty-nine (64%; 95% confidence intervals: 50-78) participants had excellent knowledge of eyecare for diabetic complications. Thirteen percent of participants had a positive attitude toward periodic eye checkups. Travel distance to an eyecare unit, no referral from family physicians for annual eye checkups and the lack of availability of gender-specific eyecare professionals were the main perceived barriers. Annual DR screening needs to be promoted to primary healthcare providers and diabetic patients. Barriers should be addressed to improve the uptake of DR screening.

  7. Possibilities of radiotherapy in eye inflammations

    International Nuclear Information System (INIS)

    Todorov, J.; Ruseva, Ts.; Gocheva, L.; Marinova, L.; Suchkova, P.; Khristova, R.; Bildirev, N.; Savov, S.

    1994-01-01

    The effect of X-ray therapy on 66 patients with chronic eye inflammations having unsatisfactory results from applied chemical treatment is analysed. X-ray generated at 200 kV with half-attenuation layer of 3 mm Al is used. By a direct field on the eyeball a single skin exposition of 25-50 P (in two days) up to a total exposition of 100-150-200 P has been applied. All patients are followed up as many as three years. The following subjective indicators are used as criteria for detecting the effect: pain, lacrimation, photophobia, eye pressure and lens transparency. It is concluded that the X-ray therapy is a reliable method and has a good influence on the subjective and objective symptoms with a stable therapeutic effect without any complications. 2 tabs., 5 refs. (orig.)

  8. Dosimetric study of the 15 mm ROPES eye plaque

    International Nuclear Information System (INIS)

    Granero, D.; Perez-Calatayud, J.; Ballester, F.; Casal, E.; Frutos, J.M. de

    2004-01-01

    The main aim of this paper is to make a study of dose-rate distributions obtained around the 15 mm, radiation oncology physics and engineering services, Australia (ROPES) eye plaque loaded with 125 I model 6711 radioactive seeds. In this study, we have carried out a comparison of the dose-rate distributions obtained by the algorithm used by the Plaque Simulator (PS) (BEBIG GmbH, Berlin, Germany) treatment planning system with those obtained by means of the Monte Carlo method for the ROPES eye plaque. A simple method to obtain the dose-rate distributions in a treatment planning system via the superposition of the dose-rate distributions of a seed placed in the eye plaque has been developed. The method uses eye plaque located in a simplified geometry of the head anatomy and distributions obtained by means of the Monte Carlo code GEANT4. The favorable results obtained in the development of this method suggest that it could be implemented on a treatment planning system to improve dose-rate calculations. We have also found that the dose-rate falls sharply along the eye and that outside the eye the dose-rate is very low. Furthermore, the lack of backscatter photons from the air located outside the eye-head phantom produces a dose reduction negligible for distances from the eye-plaque r<1 cm but reaches up to 20% near the air-eye interface. Results showed that the treatment planning system lacks accuracy around the border of the eye (in the sclera and the surrounding area) due to the simplicity of the algorithm used. The BEBIG treatment planning system uses a global attenuation factor that takes into account the effect of the eye plaque seed carrier and the lack of backscatter photons caused by the metallic cover, which in the case of a ROPES eye plaque has a default value of T=1 (no correction). In the present study, a global attenuation factor T=0.96 and an air-interface correction factor which improve on treatment planning system calculations were obtained

  9. Assessment of Corneal Biomechanical Properties by CorVis ST in Patients with Dry Eye and in Healthy Subjects

    Directory of Open Access Journals (Sweden)

    Qin Long

    2015-01-01

    Full Text Available Purpose. To investigate corneal biomechanical properties in patients with dry eye and in healthy subjects using Corneal Visualization Scheimpflug Technology (CorVis ST. Methods. Biomechanical parameters were measured using CorVis ST in 28 eyes of 28 patients with dry eye (dry eye group and 26 normal subjects (control group. The Schirmer I test value, tear film break-up time (TBUT, and corneal staining score (CSS were recorded for each eye. Biomechanical properties were compared between the two groups and bivariate correlation analysis was used to assess the relationship between biomechanical parameters and dry eye signs. Results. Only one of the ten biomechanical parameters was significantly different between the two groups. Patients in the dry eye group had significantly lower highest concavity time (HC-time (P=0.02 than the control group. Correlation analysis showed a significant negative correlation between HC-time and CSS with marginal P value (ρ=-0.39, P=0.04 in the dry eye group. Conclusions. The corneal biomechanical parameter of HC-time is reduced in dry eyes compared to normal eyes. There was also a very weak but significant negative correlation between HC-time and CSS in the dry eye group, indicating that ocular surface damage can give rise to a more compliant cornea in dry eyes.

  10. Understanding Your Vision: The "Imperfect Eye"

    Science.gov (United States)

    ... eye," amblyopia is the most common cause of visual impairment among children. The condition affects about two-to-three out ... the most common cause of monocular (one-eye) visual impairment among children and young and middle-aged adults. Helping kids ...

  11. iTemplate: A template-based eye movement data analysis approach.

    Science.gov (United States)

    Xiao, Naiqi G; Lee, Kang

    2018-02-08

    Current eye movement data analysis methods rely on defining areas of interest (AOIs). Due to the fact that AOIs are created and modified manually, variances in their size, shape, and location are unavoidable. These variances affect not only the consistency of the AOI definitions, but also the validity of the eye movement analyses based on the AOIs. To reduce the variances in AOI creation and modification and achieve a procedure to process eye movement data with high precision and efficiency, we propose a template-based eye movement data analysis method. Using a linear transformation algorithm, this method registers the eye movement data from each individual stimulus to a template. Thus, users only need to create one set of AOIs for the template in order to analyze eye movement data, rather than creating a unique set of AOIs for all individual stimuli. This change greatly reduces the error caused by the variance from manually created AOIs and boosts the efficiency of the data analysis. Furthermore, this method can help researchers prepare eye movement data for some advanced analysis approaches, such as iMap. We have developed software (iTemplate) with a graphic user interface to make this analysis method available to researchers.

  12. Eye gazing direction inspection based on image processing technique

    Science.gov (United States)

    Hao, Qun; Song, Yong

    2005-02-01

    According to the research result in neural biology, human eyes can obtain high resolution only at the center of view of field. In the research of Virtual Reality helmet, we design to detect the gazing direction of human eyes in real time and feed it back to the control system to improve the resolution of the graph at the center of field of view. In the case of current display instruments, this method can both give attention to the view field of virtual scene and resolution, and improve the immersion of virtual system greatly. Therefore, detecting the gazing direction of human eyes rapidly and exactly is the basis of realizing the design scheme of this novel VR helmet. In this paper, the conventional method of gazing direction detection that based on Purklinje spot is introduced firstly. In order to overcome the disadvantage of the method based on Purklinje spot, this paper proposed a method based on image processing to realize the detection and determination of the gazing direction. The locations of pupils and shapes of eye sockets change with the gazing directions. With the aid of these changes, analyzing the images of eyes captured by the cameras, gazing direction of human eyes can be determined finally. In this paper, experiments have been done to validate the efficiency of this method by analyzing the images. The algorithm can carry out the detection of gazing direction base on normal eye image directly, and it eliminates the need of special hardware. Experiment results show that the method is easy to implement and have high precision.

  13. Speaking and Listening with the Eyes: Gaze Signaling during Dyadic Interactions.

    Science.gov (United States)

    Ho, Simon; Foulsham, Tom; Kingstone, Alan

    2015-01-01

    Cognitive scientists have long been interested in the role that eye gaze plays in social interactions. Previous research suggests that gaze acts as a signaling mechanism and can be used to control turn-taking behaviour. However, early research on this topic employed methods of analysis that aggregated gaze information across an entire trial (or trials), which masks any temporal dynamics that may exist in social interactions. More recently, attempts have been made to understand the temporal characteristics of social gaze but little research has been conducted in a natural setting with two interacting participants. The present study combines a temporally sensitive analysis technique with modern eye tracking technology to 1) validate the overall results from earlier aggregated analyses and 2) provide insight into the specific moment-to-moment temporal characteristics of turn-taking behaviour in a natural setting. Dyads played two social guessing games (20 Questions and Heads Up) while their eyes were tracked. Our general results are in line with past aggregated data, and using cross-correlational analysis on the specific gaze and speech signals of both participants we found that 1) speakers end their turn with direct gaze at the listener and 2) the listener in turn begins to speak with averted gaze. Convergent with theoretical models of social interaction, our data suggest that eye gaze can be used to signal both the end and the beginning of a speaking turn during a social interaction. The present study offers insight into the temporal dynamics of live dyadic interactions and also provides a new method of analysis for eye gaze data when temporal relationships are of interest.

  14. Speaking and Listening with the Eyes: Gaze Signaling during Dyadic Interactions.

    Directory of Open Access Journals (Sweden)

    Simon Ho

    Full Text Available Cognitive scientists have long been interested in the role that eye gaze plays in social interactions. Previous research suggests that gaze acts as a signaling mechanism and can be used to control turn-taking behaviour. However, early research on this topic employed methods of analysis that aggregated gaze information across an entire trial (or trials, which masks any temporal dynamics that may exist in social interactions. More recently, attempts have been made to understand the temporal characteristics of social gaze but little research has been conducted in a natural setting with two interacting participants. The present study combines a temporally sensitive analysis technique with modern eye tracking technology to 1 validate the overall results from earlier aggregated analyses and 2 provide insight into the specific moment-to-moment temporal characteristics of turn-taking behaviour in a natural setting. Dyads played two social guessing games (20 Questions and Heads Up while their eyes were tracked. Our general results are in line with past aggregated data, and using cross-correlational analysis on the specific gaze and speech signals of both participants we found that 1 speakers end their turn with direct gaze at the listener and 2 the listener in turn begins to speak with averted gaze. Convergent with theoretical models of social interaction, our data suggest that eye gaze can be used to signal both the end and the beginning of a speaking turn during a social interaction. The present study offers insight into the temporal dynamics of live dyadic interactions and also provides a new method of analysis for eye gaze data when temporal relationships are of interest.

  15. Evaluation of treatment for dry eye with 2-hydroxyestradiol using a dry eye rat model.

    Science.gov (United States)

    Higuchi, Akihiro; Oonishi, Erina; Kawakita, Tetsuya; Tsubota, Kazuo

    2016-01-01

    2-hydroxy estradiol (2-OHE2) is a catechol derivative of 17β -Estradiol (E2) and it is synthesized from E2 catalyzed by cytochrome P4501A1. Previous studies reported that 2-OHE2 is a physiologic antioxidant in lipoproteins, liver microsomes, and the brain. Catechol derivatives show an anti-inflammatory effect through the inhibition of prostaglandin endoperoxide synthase (PGS) activity. Corneal erosion caused by dry eye is related to an increase in oxidative stress and inflammation in ocular surface cells. We investigated the therapeutic effects of 2-OHE2 on corneal damage caused by dry eye. Steroidal radical scavenging activity was confirmed through the electron spin resonance (ESR) method. PGS activity was measured using the COX Fluorescent Activity Assay Kit. To evaluate the effect of 2-OHE2 on the treatment for dry eye, 2-OHE2 was applied as an eye drop experiment using dry eye model rats. 2-OHE2 scavenged tyrosyl radical and possibly suppressed oxidative stress in corneal epithelial cells. In addition, 2-OHE2 inhibited PGS activity, and 2-OHE2 is probably a competitive inhibitor of PGS. Corneal PGS activity was upregulated in the dry eye group. Therefore, 2-OHE2 eye drops improved corneal erosion in dry eye model rats. 2-OHE2 is a candidate for the treatment of dry eye through the suppression of inflammation and oxidative stress in the cornea.

  16. Eye wash water flow direction study: an evaluation of the effectiveness of eye wash devices with opposite directional water flow

    OpenAIRE

    Fogt JS; Jones-Jordan LA; Barr JT

    2018-01-01

    Jennifer S Fogt, Lisa A Jones-Jordan, Joseph T Barr The Ohio State University College of Optometry, Columbus, OH, USA Introduction: New designs of eye wash stations have been developed in which the direction of water flow from the fountain has been reversed, with two water streams originating nasally in both eyes and flowing toward the temporal side of each eye. No study has been done to determine the ideal direction of water flow coming from the eye wash in relation to the eye. Materials ...

  17. Fish freshness estimation using eye image processing under white and UV lightings

    Science.gov (United States)

    Kanamori, Katsuhiro; Shirataki, Yuri; Liao, Qiuhong; Ogawa, Yuichi; Suzuki, Tetsuhito; Kondo, Naoshi

    2017-05-01

    A non-destructive method of estimating the freshness of fish is required for appropriate price setting and food safety. In particular, for determining the possibility of eating raw fish (sashimi), freshness estimation is critical. We studied such an estimation method by capturing images of fish eyes and performing image processing using the temporal changes of the luminance of pupil and iris. To detect subtle non-visible changes of these features, we used UV (375 nm) light illumination in addition to visible white light illumination. Polarization and two-channel LED techniques were used to remove strong specular reflection from the cornea of the eye and from clear-plastic wrap used to cover the fish to maintain humidity. Pupil and iris regions were automatically detected separately by image processing after the specular reflection removal process, and two types of eye contrast were defined as the ratio of mean and median pixel values of each region. Experiments using 16 Japanese dace (Tribolodon hakonensis) at 23° and 85% humidity for 24 hours were performed. The eye contrast of raw fish increase non-linearly in the initial period and then decreased; however, that of frozen-thawed fish decreased linearly throughout 24 hours, regardless of the lighting. Interestingly, the eye contrast using UV light showed a higher correlation with time than that using white light only in the case of raw fish within the early 6- hour period postmortem. These results show the possibility of estimating fish freshness in the initial stage when fish are eaten raw using white and UV lightings.

  18. Does the 'P300' speller depend on eye gaze?

    Science.gov (United States)

    Brunner, P.; Joshi, S.; Briskin, S.; Wolpaw, J. R.; Bischof, H.; Schalk, G.

    2010-10-01

    Many people affected by debilitating neuromuscular disorders such as amyotrophic lateral sclerosis, brainstem stroke or spinal cord injury are impaired in their ability to, or are even unable to, communicate. A brain-computer interface (BCI) uses brain signals, rather than muscles, to re-establish communication with the outside world. One particular BCI approach is the so-called 'P300 matrix speller' that was first described by Farwell and Donchin (1988 Electroencephalogr. Clin. Neurophysiol. 70 510-23). It has been widely assumed that this method does not depend on the ability to focus on the desired character, because it was thought that it relies primarily on the P300-evoked potential and minimally, if at all, on other EEG features such as the visual-evoked potential (VEP). This issue is highly relevant for the clinical application of this BCI method, because eye movements may be impaired or lost in the relevant user population. This study investigated the extent to which the performance in a 'P300' speller BCI depends on eye gaze. We evaluated the performance of 17 healthy subjects using a 'P300' matrix speller under two conditions. Under one condition ('letter'), the subjects focused their eye gaze on the intended letter, while under the second condition ('center'), the subjects focused their eye gaze on a fixation cross that was located in the center of the matrix. The results show that the performance of the 'P300' matrix speller in normal subjects depends in considerable measure on gaze direction. They thereby disprove a widespread assumption in BCI research, and suggest that this BCI might function more effectively for people who retain some eye-movement control. The applicability of these findings to people with severe neuromuscular disabilities (particularly in eye-movements) remains to be determined.

  19. Generating and Describing Affective Eye Behaviors

    Science.gov (United States)

    Mao, Xia; Li, Zheng

    The manner of a person's eye movement conveys much about nonverbal information and emotional intent beyond speech. This paper describes work on expressing emotion through eye behaviors in virtual agents based on the parameters selected from the AU-Coded facial expression database and real-time eye movement data (pupil size, blink rate and saccade). A rule-based approach to generate primary (joyful, sad, angry, afraid, disgusted and surprise) and intermediate emotions (emotions that can be represented as the mixture of two primary emotions) utilized the MPEG4 FAPs (facial animation parameters) is introduced. Meanwhile, based on our research, a scripting tool, named EEMML (Emotional Eye Movement Markup Language) that enables authors to describe and generate emotional eye movement of virtual agents, is proposed.

  20. Eyes and ears: Using eye tracking and pupillometry to understand challenges to speech recognition.

    Science.gov (United States)

    Van Engen, Kristin J; McLaughlin, Drew J

    2018-05-04

    Although human speech recognition is often experienced as relatively effortless, a number of common challenges can render the task more difficult. Such challenges may originate in talkers (e.g., unfamiliar accents, varying speech styles), the environment (e.g. noise), or in listeners themselves (e.g., hearing loss, aging, different native language backgrounds). Each of these challenges can reduce the intelligibility of spoken language, but even when intelligibility remains high, they can place greater processing demands on listeners. Noisy conditions, for example, can lead to poorer recall for speech, even when it has been correctly understood. Speech intelligibility measures, memory tasks, and subjective reports of listener difficulty all provide critical information about the effects of such challenges on speech recognition. Eye tracking and pupillometry complement these methods by providing objective physiological measures of online cognitive processing during listening. Eye tracking records the moment-to-moment direction of listeners' visual attention, which is closely time-locked to unfolding speech signals, and pupillometry measures the moment-to-moment size of listeners' pupils, which dilate in response to increased cognitive load. In this paper, we review the uses of these two methods for studying challenges to speech recognition. Copyright © 2018. Published by Elsevier B.V.

  1. Comparison of two methods of tonometry in glaucoma patients: Goldmann applanation tonometer and non-contact tonometer

    Directory of Open Access Journals (Sweden)

    Hong-Feng Li

    2015-01-01

    Full Text Available AIM: To compare the two methods for the measurement of glaucoma patients' intraocular pressure(IOPbetween Goldmann applanation tonometer(GATand non-contact tonometer(NCTand find the laws of the two methods.METHODS: The IOP of 108 glaucoma patients(206 eyeswere measured by GAT and NCT respectively. RESULTS: In 108 glaucoma patients, the average IOP of 206 eyes was 29.77±10.27mmHg by GAT and 24.59±8.58mmHg by NCT. There was significant difference between GAT and NCT(PCONCLUSION: The measurement results with NCT were lower than that of GAT. The higher of IOP, the difference between GAT and NCT was greater. It's better to measure IOP by GAT for the glaucoma patients, in order to avoid the misdiagnosis and mistreatment of glaucoma.

  2. BEDVH--A method for evaluating biologically effective dose volume histograms: Application to eye plaque brachytherapy implants

    International Nuclear Information System (INIS)

    Gagne, Nolan L.; Leonard, Kara L.; Huber, Kathryn E.; Mignano, John E.; Duker, Jay S.; Laver, Nora V.; Rivard, Mark J.

    2012-01-01

    Purpose: A method is introduced to examine the influence of implant duration T, radionuclide, and radiobiological parameters on the biologically effective dose (BED) throughout the entire volume of regions of interest for episcleral brachytherapy using available radionuclides. This method is employed to evaluate a particular eye plaque brachytherapy implant in a radiobiological context. Methods: A reference eye geometry and 16 mm COMS eye plaque loaded with 103 Pd, 125 I, or 131 Cs sources were examined with dose distributions accounting for plaque heterogeneities. For a standardized 7 day implant, doses to 90% of the tumor volume ( TUMOR D 90 ) and 10% of the organ at risk volumes ( OAR D 10 ) were calculated. The BED equation from Dale and Jones and published α/β and μ parameters were incorporated with dose volume histograms (DVHs) for various T values such as T = 7 days (i.e., TUMOR 7 BED 10 and OAR 7 BED 10 ). By calculating BED throughout the volumes, biologically effective dose volume histograms (BEDVHs) were developed for tumor and OARs. Influence of T, radionuclide choice, and radiobiological parameters on TUMOR BEDVH and OAR BEDVH were examined. The nominal dose was scaled for shorter implants to achieve biological equivalence. Results: TUMOR D 90 values were 102, 112, and 110 Gy for 103 Pd, 125 I, and 131 Cs, respectively. Corresponding TUMOR 7 BED 10 values were 124, 140, and 138 Gy, respectively. As T decreased from 7 to 0.01 days, the isobiologically effective prescription dose decreased by a factor of three. As expected, TUMOR 7 BEDVH did not significantly change as a function of radionuclide half-life but varied by 10% due to radionuclide dose distribution. Variations in reported radiobiological parameters caused TUMOR 7 BED 10 to deviate by up to 46%. Over the range of OAR α/β values, OAR 7 BED 10 varied by up to 41%, 3.1%, and 1.4% for the lens, optic nerve, and lacrimal gland, respectively. Conclusions: BEDVH permits evaluation of the

  3. Twenty-One at TREC-8: using Language Technology for Information Retrieval

    NARCIS (Netherlands)

    Kraaij, Wessel; Pohlmann, Renée; Hiemstra, Djoerd; Voorhees, E.M; Harman, D.K.

    2000-01-01

    This paper describes the official runs of the Twenty-One group for TREC-8. The Twenty-One group participated in the Ad-hoc, CLIR, Adaptive Filtering and SDR tracks. The main focus of our experiments is the development and evaluation of retrieval methods that are motivated by natural language

  4. Acanthamoeba Keratitis at the King Khaled Eye Specialist Hospital

    International Nuclear Information System (INIS)

    Al-Mezaine, H.; Al-Muteb, M.; Al-Motowa, S.; Wagoner, M. D.

    2005-01-01

    To quantify the number of cases and clinical courses of Acanthamoeba keratitis treated at the King Khaled Eye Specialist Hospital (KKESH) between December 1982 and May 2005, and to review their clinical course and response to medical and surgical therapy. Retrospective review of medical records of all patients with Acanthamoeba keratitis diagnosed by the KKESH Microbiology or Pathology or Pathology Laboratory since the opening of the hospital. During a period of over 22 years, only six cases of confirmed. Acanthamoeba keratitis were diagnosedand treated at KKESH. In two cases the diagnosis was made by corneal biopsy, while four cases required examination of a histopathology specimen obtained at the time of therapeutic keratoplasty to establish the diagnosis. One eye was cured by medical therapy, while five eyes required one (4eyes) or two (1 eye) therapeutic penetrating keratoplasty (PKP) to achieve a clinical cure. Three eyes achieved good visual acuity (20/40, 20/50, 20/60), one eye achieved fair visual acuity (20/160), and two eyes suffered profound visual loss (hand motions). The incidence of Acanthamoeba keratitis may be less in Saudi Arabia than reported in Western countries although the clinical is similarly complicated, with most cases requiring therapeutic keratoplasty for definitive education of the organism. (author)

  5. Eye tracking in user experience design

    CERN Document Server

    Romano Bergstorm, Jennifer

    2014-01-01

    Eye Tracking for User Experience Design explores the many applications of eye tracking to better understand how users view and interact with technology. Ten leading experts in eye tracking discuss how they have taken advantage of this new technology to understand, design, and evaluate user experience. Real-world stories are included from these experts who have used eye tracking during the design and development of products ranging from information websites to immersive games. They also explore recent advances in the technology which tracks how users interact with mobile devices, large-screen displays and video game consoles. Methods for combining eye tracking with other research techniques for a more holistic understanding of the user experience are discussed. This is an invaluable resource to those who want to learn how eye tracking can be used to better understand and design for their users. * Includes highly relevant examples and information for those who perform user research and design interactive experi...

  6. Effect of lipid-based dry eye supplements on the tear film in wearers of eye cosmetics.

    Science.gov (United States)

    Wang, Michael T M; Cho, Irene Sung Hee; Jung, Soo Hee; Craig, Jennifer P

    2017-08-01

    To compare the effects on tear film parameters and contamination in cosmetic eyeliner wearers, after single application of two lipid-based dry eye treatments: a lipid-containing lubricant eye drop and a phospholipid liposomal spray. Fifty participants were enrolled in a prospective, randomised, paired-eye, investigator-masked trial. Pencil eyeliner (Body Shop ® Crayon Eye Definer) was applied to the upper eyelid periocular skin of both eyes, anterior to the lash line. Baseline tear film quality was assessed fifteen minutes after eyeliner application. A lubricant drop (Systane ® Balance) was then applied to one eye (randomised), and liposomal spray (Tears Again ® ) to the contralateral eye. Tear film contamination, lipid layer grade, non-invasive tear film break-up time and tear evaporation rate were evaluated fifteen minutes post-treatment and compared to pre-treatment values. Pre-treatment measurements did not differ between eyes assigned to lubricant drop and liposomal spray. Tear film contamination was observed in a greater proportion of eyes following both treatments (both p0.05). Changes in tear film parameters did not differ between treatments (all p>0.05). Both the lipid-containing lubricant eye drop and phospholipid liposomal spray result in clinically apparent tear film contamination in eyeliner cosmetic wearers. Although both treatments effected an increase in lipid layer thickness, neither displayed clinical efficacy in improving tear film stability. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  7. The Role of Eye Movement Desensitization and Reprocessing (EMDR) Therapy in Medicine: Addressing the Psychological and Physical Symptoms Stemming from Adverse Life Experiences

    OpenAIRE

    Shapiro, Francine

    2014-01-01

    A substantial body of research shows that adverse life experiences contribute to both psychological and biomedical pathology. Twenty-four randomized controlled trials support the positive effects of eye movement desensitization and reprocessing therapy in the treatment of emotional trauma and other adverse life experiences relevant to clinical practice. Twelve randomized studies of the eye movement component noted rapid decreases in negative emotions and/or vividness of disturbing images.

  8. Eye Protection

    OpenAIRE

    Pashby, Tom

    1986-01-01

    Eye injuries frequently occur in the home, at work and at play. Many result in legally blind eyes, and most are preventable. Awareness of potential hazards is essential to preventing eye injuries, particularly in children. In addition, protective devices must be used appropriately. We have developed eye protectors that have proved effective in reducing both the overall incidence and the severity of sports eye injuries.

  9. A novel method for measuring anterior segment area of the eye on ultrasound biomicroscopic images using photoshop.

    Directory of Open Access Journals (Sweden)

    Zhonghao Wang

    Full Text Available To describe a novel method for quantitative measurement of area parameters in ocular anterior segment ultrasound biomicroscopy (UBM images using Photoshop software and to assess its intraobserver and interobserver reproducibility.Twenty healthy volunteers with wide angles and twenty patients with narrow or closed angles were consecutively recruited. UBM images were obtained and analyzed using Photoshop software by two physicians with different-level training on two occasions. Borders of anterior segment structures including cornea, iris, lens, and zonules in the UBM image were semi-automatically defined by the Magnetic Lasso Tool in the Photoshop software according to the pixel contrast and modified by the observers. Anterior chamber area (ACA, posterior chamber area (PCA, iris cross-section area (ICA and angle recess area (ARA were drawn and measured. The intraobserver and interobserver reproducibilities of the anterior segment area parameters and scleral spur location were assessed by limits of agreement, coefficient of variation (CV, and intraclass correlation coefficient (ICC.All of the parameters were successfully measured by Photoshop. The intraobserver and interobserver reproducibilities of ACA, PCA, and ICA were good, with no more than 5% CV and more than 0.95 ICC, while the CVs of ARA were within 20%. The intraobserver and interobserver reproducibilities for defining the spur location were more than 0.97 ICCs. Although the operating times for both observers were less than 3 minutes per image, there was significant difference in the measuring time between two observers with different levels of training (p<0.001.Measurements of ocular anterior segment areas on UBM images by Photoshop showed good intraobserver and interobserver reproducibilties. The methodology was easy to adopt and effective in measuring.

  10. 1st Workshop on Eye Tracking and Visualization

    CERN Document Server

    Chuang, Lewis; Fisher, Brian; Schmidt, Albrecht; Weiskopf, Daniel

    2017-01-01

    This book discusses research, methods, and recent developments in the interdisciplinary field that spans research in visualization, eye tracking, human-computer interaction, and psychology. It presents extended versions of papers from the First Workshop on Eye Tracking and Visualization (ETVIS), which was organized as a workshop of the IEEE VIS Conference 2015. Topics include visualization and visual analytics of eye-tracking data, metrics and cognitive models, eye-tracking experiments in the context of visualization interfaces, and eye tracking in 3D and immersive environments. The extended ETVIS papers are complemented by a chapter offering an overview of visualization approaches for analyzing eye-tracking data and a chapter that discusses electrooculography (EOG) as an alternative of acquiring information about eye movements. Covering scientific visualization, information visualization, and visual analytics, this book is a valuable resource for eye-tracking researchers within the visualization community.

  11. Diabetes eye exams

    Science.gov (United States)

    Diabetic retinopathy - eye exams; Diabetes - eye exams; Glaucoma - diabetic eye exam; Macular edema - diabetic eye exam ... if the doctor who takes care of your diabetes checks your eyes, you need an eye exam ...

  12. Combined eye-atmosphere visibility model

    Science.gov (United States)

    Kaufman, Y. J.

    1981-01-01

    Existing models of the optical characteristics of the eye are combined with a recent model of optical characteristics of the atmosphere given by its modulation transfer function. This combination results in the combined eye-atmosphere performance given by the product of their modulation transfer functions. An application for the calculation of visibility thresholds in the case of a two-halves field is given.

  13. Twenty-five gauge vitrectomy in uveitis

    Directory of Open Access Journals (Sweden)

    Roger Roberto Wada Kamei

    2012-04-01

    Full Text Available PURPOSE: To evaluate anatomical and functional results of 25-gauge transconjunctival sutureless pars plana vitrectomy in patients with uveitis. METHODS: Vitrectomy was performed on 20 eyes with residual vitritis secondary to infectious and noninfectious uveitis. Patients were evaluated 1 week before surgery and after surgery at day 1, week 1, week 4 and week 12. Visual acuity (VA, intraocular pressure, anterior chamber cells and flare and vitreous haze were measured. RESULTS: Mean VA improved from 2.06 ± 0.94 logMAR before surgery to 0.58 ± 0.46 logMAR at week 12 (p<0.05. No case required conversion to standard 20-gauge instrumentation or suture placement, no intraoperative complications were noted. Transient postoperative hypotony was seen in three eyes. One patient with toxoplasmic retinochoroiditis had a relapse during follow-up. CONCLUSION: 25-gauge vitrectomy has proven its efficacy on cleansing vitreous opacities and improving visual acuity on patients with residual vitritis secondary to uveitis with minimal postoperative inflammation and complications.

  14. Protecting the ocular surface and improving the quality of life of dry eye patients: a study of the efficacy of an HP-guar containing ocular lubricant in a population of dry eye patients.

    Science.gov (United States)

    Rolando, Maurizio; Autori, Silvia; Badino, Francesco; Barabino, Stefano

    2009-06-01

    The aim of this study was to evaluate the efficacy of a non-Newtonian tear substitute containing 0.4% polyethylene glycol 400 (PEG 400) and 0.3% propylene glycol in an 0.18% hydroxypropyl-guar (HPG) containing vehicle (Systane Lubricant Eye Drops; Alcon) in reducing the signs and symptoms of dry eye, as well as its effect on ocular protection. Twenty patients with moderate to severe dry eye were enrolled in a 28-day prospective, randomized, controlled study. Subjects self-administered the HPG containing ocular lubricant four times daily (QID) over the study duration. After 28 days, the effect of the HPG containing ocular lubricant was evaluated by means of the Global Staining Score (a measure of the corneal and conjunctival staining), inter-blink tear film stability, Ocular Protection Index (OPI), and subjective symptoms. The HPG containing ocular lubricant produced statistically significant improvements compared with baseline in dry eye symptoms (P eye symptoms with the HPG containing ocular lubricant -- evident as early as the first follow-up visit (Day 7) and continued throughout the 28 days of the study with a concurrent, increase in OPI to a level greater than unity -- indicate that this preparation is a fast-acting, long-lasting, and effective treatment for dry eye. In concurrence with the results from previously published clinical studies, the HPG containing ocular lubricant has shown efficacy in alleviating the signs and symptoms of dry eye as well as affording improved ocular surface protection.

  15. A novel algorithm for automatic localization of human eyes

    Institute of Scientific and Technical Information of China (English)

    Liang Tao (陶亮); Juanjuan Gu (顾涓涓); Zhenquan Zhuang (庄镇泉)

    2003-01-01

    Based on geometrical facial features and image segmentation, we present a novel algorithm for automatic localization of human eyes in grayscale or color still images with complex background. Firstly, a determination criterion of eye location is established by the prior knowledge of geometrical facial features. Secondly,a range of threshold values that would separate eye blocks from others in a segmented face image (I.e.,a binary image) are estimated. Thirdly, with the progressive increase of the threshold by an appropriate step in that range, once two eye blocks appear from the segmented image, they will be detected by the determination criterion of eye location. Finally, the 2D correlation coefficient is used as a symmetry similarity measure to check the factuality of the two detected eyes. To avoid the background interference, skin color segmentation can be applied in order to enhance the accuracy of eye detection. The experimental results demonstrate the high efficiency of the algorithm and correct localization rate.

  16. CON4EI: SkinEthic™ Human Corneal Epithelium Eye Irritation Test (SkinEthic™ HCE EIT) for hazard identification and labelling of eye irritating chemicals.

    Science.gov (United States)

    Van Rompay, A R; Alépée, N; Nardelli, L; Hollanders, K; Leblanc, V; Drzewiecka, A; Gruszka, K; Guest, R; Kandarova, H; Willoughby, J A; Verstraelen, S; Adriaens, E

    2018-06-01

    Assessment of ocular irritancy is an international regulatory requirement and a necessary step in the safety evaluation of industrial and consumer products. Although a number of in vitro ocular irritation assays exist, none are capable of fully categorizing chemicals as a stand-alone assay. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was developed with the goal of assessing the reliability of eight in vitro/alternative test methods as well as establishing an optimal tiered-testing strategy. One of the in vitro assays selected was the validated SkinEthic™ Human Corneal Epithelium Eye Irritation Test method (SkinEthic™ HCE EIT). The SkinEthic™ HCE EIT has already demonstrated its capacity to correctly identify chemicals (both substances and mixtures) not requiring classification and labelling for eye irritation or serious eye damage (No Category). The goal of this study was to evaluate the performance of the SkinEthic™ HCE EIT test method in terms of the important in vivo drivers of classification. For the performance with respect to the drivers all in vivo Cat 1 and No Cat chemicals were 100% correctly identified. For Cat 2 chemicals the liquids and the solids had a sensitivity of 100% and 85.7%, respectively. For the SkinEthic™ HCE EIT test method, 100% concordance in predictions (No Cat versus No prediction can be made) between the two participating laboratories was obtained. The accuracy of the SkinEthic™ HCE EIT was 97.5% with 100% sensitivity and 96.9% specificity. The SkinEthic™ HCE EIT confirms its excellent results of the validation studies. Copyright © 2017. Published by Elsevier Ltd.

  17. Reading paths, eye drawings, and word islands: Movement in Un coup de dés.

    Science.gov (United States)

    Loos, Ruth

    2012-01-01

    In the framework of an artistic-scientific project on eye-movements during reading, my collaborators from the psychology department at the KU Leuven and I had a close look at the poem "Un coup de dés jamais n'abolira le hasard" ("A throw of the dice will never abolish chance") by Stéphane Mallarmé. The poem is an intriguing example of nonlinear writing, of a typographic game with white and space, and of an interweaving of different reading lines. These specific features evoke multiple reading methods. The animation, Movement in Un coup de dés, created during the still-ongoing collaboration interweaves a horizontal and a vertical reading method, two spontaneous ways of reading that point at the poem's intriguing ambiguity. Not only are we interested in different methods of reading; the scientific representations of eye movements themselves are a rich source of images with much artistic potential. We explore eye movements as "eye drawings" in new images characterized both by a scientific and by an artistic perspective.

  18. Reading Paths, Eye Drawings, and Word Islands: Movement in Un coup de dés

    Directory of Open Access Journals (Sweden)

    Ruth Loos

    2012-01-01

    Full Text Available In the framework of an artistic–scientific project on eye-movements during reading, my collaborators from the psychology department at the KU Leuven and I had a close look at the poem “Un coup de dés jamais n'abolira le hasard” (“A throw of the dice will never abolish chance” by Stéphane Mallarmé. The poem is an intriguing example of nonlinear writing, of a typographic game with white and space, and of an interweaving of different reading lines. These specific features evoke multiple reading methods. The animation, Movement in Un coup de dés, created during the still-ongoing collaboration interweaves a horizontal and a vertical reading method, two spontaneous ways of reading that point at the poem's intriguing ambiguity. Not only are we interested in different methods of reading; the scientific representations of eye movements themselves are a rich source of images with much artistic potential. We explore eye movements as “eye drawings” in new images characterized both by a scientific and by an artistic perspective.

  19. Use of EyeCam for imaging the anterior chamber angle.

    Science.gov (United States)

    Perera, Shamira A; Baskaran, Mani; Friedman, David S; Tun, Tin A; Htoon, Hla M; Kumar, Rajesh S; Aung, Tin

    2010-06-01

    To compare EyeCam (Clarity Medical Systems, Pleasanton, CA) imaging with gonioscopy for detecting angle closure. In this prospective, hospital-based study, subjects underwent gonioscopy by a single observer and EyeCam imaging by a different operator. EyeCam images were graded by two masked observers. The anterior chamber angle in a quadrant was classified as closed if the trabecular meshwork could not be seen. The eye was classified as having angle closure if two or more quadrants were closed. One hundred fifty-two subjects were studied. The mean age was 57.4 years (SD 12.9) and there were 82 (54%) men. Of the 152 eyes, 21 (13.8%) had angle closure. The EyeCam provided clear images of the angles in 98.8% of subjects. The agreement between the EyeCam and gonioscopy for detecting angle closure in the superior, inferior, nasal, and temporal quadrants based on agreement coefficient (AC1) statistics was 0.73, 0.75, 0.76, and 0.72, respectively. EyeCam detected more closed angles than did gonioscopy in all quadrants (P gonioscopy, 21/152 (13.8%) eyes were diagnosed as angle closure compared to 41 (27.0%) of 152 with EyeCam (P gonioscopy for detecting angle closure. However, it detected more closed angles than did gonioscopy in all quadrants.

  20. Implicit prosody mining based on the human eye image capture technology

    Science.gov (United States)

    Gao, Pei-pei; Liu, Feng

    2013-08-01

    The technology of eye tracker has become the main methods of analyzing the recognition issues in human-computer interaction. Human eye image capture is the key problem of the eye tracking. Based on further research, a new human-computer interaction method introduced to enrich the form of speech synthetic. We propose a method of Implicit Prosody mining based on the human eye image capture technology to extract the parameters from the image of human eyes when reading, control and drive prosody generation in speech synthesis, and establish prosodic model with high simulation accuracy. Duration model is key issues for prosody generation. For the duration model, this paper put forward a new idea for obtaining gaze duration of eyes when reading based on the eye image capture technology, and synchronous controlling this duration and pronunciation duration in speech synthesis. The movement of human eyes during reading is a comprehensive multi-factor interactive process, such as gaze, twitching and backsight. Therefore, how to extract the appropriate information from the image of human eyes need to be considered and the gaze regularity of eyes need to be obtained as references of modeling. Based on the analysis of current three kinds of eye movement control model and the characteristics of the Implicit Prosody reading, relative independence between speech processing system of text and eye movement control system was discussed. It was proved that under the same text familiarity condition, gaze duration of eyes when reading and internal voice pronunciation duration are synchronous. The eye gaze duration model based on the Chinese language level prosodic structure was presented to change previous methods of machine learning and probability forecasting, obtain readers' real internal reading rhythm and to synthesize voice with personalized rhythm. This research will enrich human-computer interactive form, and will be practical significance and application prospect in terms of

  1. Eye Absence Does Not Regulate Planarian Stem Cells during Eye Regeneration.

    Science.gov (United States)

    LoCascio, Samuel A; Lapan, Sylvain W; Reddien, Peter W

    2017-02-27

    Dividing cells called neoblasts contain pluripotent stem cells and drive planarian flatworm regeneration from diverse injuries. A long-standing question is whether neoblasts directly sense and respond to the identity of missing tissues during regeneration. We used the eye to investigate this question. Surprisingly, eye removal was neither sufficient nor necessary for neoblasts to increase eye progenitor production. Neoblasts normally increase eye progenitor production following decapitation, facilitating regeneration. Eye removal alone, however, did not induce this response. Eye regeneration following eye-specific resection resulted from homeostatic rates of eye progenitor production and less cell death in the regenerating eye. Conversely, large head injuries that left eyes intact increased eye progenitor production. Large injuries also non-specifically increased progenitor production for multiple uninjured tissues. We propose a model for eye regeneration in which eye tissue production by planarian stem cells is not directly regulated by the absence of the eye itself. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Curative effect of moisturizing eye decoction combined with artificial tears in treatment on ophthalmoxerosis

    Directory of Open Access Journals (Sweden)

    Yu-Ping Ren

    2017-08-01

    Full Text Available AIM: To observe the clinical effects of moisturizing eye decoction combined with artificial tears in the treatment of ophthalmoxerosis.METHODS: A randomized controlled clinical research method was employed. One hundred-sixty patients diagnosed with ophthalmoxerosis were equally divided into a treatment group and a control group. In the treatment group, patients were given one dose per day of the moisturizing eye decoction as well as artificial tear drops three times a day. The patients in the control group were treated with artificial tears drops three times a day. The course of treatment was 3mo. Dry-eye symptoms, tear break-up time(BUTby the slit lamp, the time of tear secretion(Schirmers Ⅰ test, corneal fluorescein staining(FL, and curative effects were observed before treatment as well as in the first and third months after treatment.RESULTS: There were no significant differences between the two groups in terms of BUT, SⅠt, and FL before treatment(P>0.05. After treatment in the first and the third months, the BUT, SⅠt, FL, and curative effects were significantly different between the two groups(PCONCLUSION: Moisturizing eye decoction combined with artificial tears in the treatment of ophthalmoxerosis can improve efficacy.

  3. Assessment of minimum permissible geometrical parameters of a near-to-eye display.

    Science.gov (United States)

    Valyukh, Sergiy; Slobodyanyuk, Oleksandr

    2015-07-20

    Light weight and small dimensions are some of the most important characteristics of near-to-eye displays (NEDs). These displays consist of two basic parts: a microdisplay for generating an image and supplementary optics in order to see the image. Nowadays, the pixel size of microdisplays may be less than 4 μm, which makes the supplementary optics the major factor in defining restrictions on a NED dimensions or at least on the distance between the microdisplay and the eye. The goal of the present work is to find answers to the following two questions: how small this distance can be in principle and what is the microdisplay maximum resolution that stays effective to see through the supplementary optics placed in immediate vicinity of the eye. To explore the first question, we consider an aberration-free magnifier, which is the initial stage in elaboration of a real optical system. In this case, the paraxial approximation and the transfer matrix method are ideal tools for simulation of light propagation from the microdisplay through the magnifier and the human eye's optical system to the retina. The human eye is considered according to the Gullstrand model. Parameters of the magnifier, its location with respect to the eye and the microdisplay, and the depth of field, which can be interpreted as the tolerance of the microdisplay position, are determined and discussed. The second question related to the microdisplay maximum resolution is investigated by using the principles of wave optics.

  4. Outcomes of Thermal Pulsation Treatment for Dry Eye Syndrome in Patients With Sjogren Disease.

    Science.gov (United States)

    Godin, Morgan R; Stinnett, Sandra S; Gupta, Preeya K

    2018-04-26

    To evaluate the clinical outcomes of thermal pulsation treatment in patients with meibomian gland dysfunction (MGD) and dry eye secondary to Sjogren disease. Twenty-four eyes from 13 patients with previously diagnosed Sjogren disease who presented to our institution with dry eye symptoms and had thermal pulsation treatment were prospectively followed up. Patients underwent comprehensive slit-lamp examination, including MGD grading, gland oil flow, corneal and conjunctival staining scores, and tear break-up time (TBUT). Tear osmolarity was tested before and after treatment. The average patient age was 62.4 years (range, 31-78 yrs); 12 were women and 1 a man. The average meibomian gland oil flow score showed an increase from pretreatment 0.71 to 1.75 at 1 year posttreatment (range 9-15 months) (P = 0.001). The average corneal staining score decreased from a pretreatment grade of 1.04 to a posttreatment grade of 0.36 (P dry eye disease in patients with Sjogren disease and should not be overlooked when considering treatment options. Thermal pulsation is a therapeutic option for patients with Sjogren disease who have MGD and dry eye symptoms. After a single treatment, patients exhibited increased oil flow and tear break-up time with an associated decrease in corneal and conjunctival staining.

  5. A role of the human thalamus in predicting the perceptual consequences of eye movements

    Directory of Open Access Journals (Sweden)

    Florian eOstendorf

    2013-04-01

    Full Text Available Internal monitoring of oculomotor commands may help to anticipate and keep track of changes in perceptual input imposed by our eye movements. Neurophysiological studies in non-human primates identified corollary discharge signals of oculomotor commands that are conveyed via thalamus to frontal cortices. We tested whether disruption of these monitoring pathways on the thalamic level impairs the perceptual matching of visual input before and after an eye movement in human subjects. Fourteen patients with focal thalamic stroke and twenty healthy control subjects performed a task requiring a perceptual judgment across eye movements. Subjects reported the apparent displacement of a target cue that jumped unpredictably in sync with a saccadic eye movement. In a critical condition of this task, six patients exhibited clearly asymmetric perceptual performance for rightward versus leftward saccade direction. Furthermore, perceptual judgments in seven patients systematically depended on oculomotor targeting errors, with self-generated targeting errors erroneously attributed to external stimulus jumps. Voxel-based lesion-symptom mapping identified an area in right central thalamus as critical for the perceptual matching of visual space across eye movements. Our findings suggest that trans-thalamic corollary discharge transmission decisively contributes to a correct prediction of the perceptual consequences of oculomotor actions.

  6. Topography and Higher Order Corneal Aberrations of the Fellow Eye in Unilateral Keratoconus.

    Science.gov (United States)

    Aksoy, Sibel; Akkaya, Sezen; Özkurt, Yelda; Kurna, Sevda; Açıkalın, Banu; Şengör, Tomris

    2017-10-01

    Comparison of topography and corneal higher order aberrations (HOA) data of fellow normal eyes of unilateral keratoconus patients with keratoconus eyes and control group. The records of 196 patients with keratoconus were reviewed. Twenty patients were identified as unilateral keratoconus. The best corrected visual acuity (BCVA), topography and aberration data of the unilateral keratoconus patients' normal eyes were compared with their contralateral keratoconus eyes and with control group eyes. For statistical analysis, flat and steep keratometry values, average corneal power, cylindrical power, surface regularity index (SRI), surface asymmetry index (SAI), inferior-superior ratio (I-S), keratoconus prediction index, and elevation-depression power (EDP) and diameter (EDD) topography indices were selected. Mean age of the unilateral keratoconus patients was 26.05±4.73 years and that of the control group was 23.6±8.53 years (p>0.05). There was no statistical difference in BCVA between normal and control eyes (p=0.108), whereas BCVA values were significantly lower in eyes with keratoconus (p=0.001). Comparison of quantitative topographic indices between the groups showed that all indices except the I-S ratio were significantly higher in the normal group than in the control group (p<0.05). The most obvious differences were in the SRI, SAI, EDP, and EDD values. All topographic indices were higher in the keratoconus eyes compared to the normal fellow eyes. There was no difference between normal eyes and the control group in terms of spherical aberration, while coma, trefoil, irregular astigmatism, and total HOA values were higher in the normal eyes of unilateral keratoconus patients (p<0.05). All HOA values were higher in keratoconus eyes than in the control group. According to our study, SRI, SAI, EDP, EDD values, and HOA other than spherical aberration were higher in the clinically and topographically normal fellow eyes of unilateral keratoconus patients when compared

  7. Eye-Drops for Activation of DREADDs

    Directory of Open Access Journals (Sweden)

    William T. Keenan

    2017-11-01

    Full Text Available Designer Receptors Exclusively Activated by Designer Drugs (DREADDs are an important tool for modulating and understanding neural circuits. Depending on the DREADD system used, DREADD-targeted neurons can be activated or repressed in vivo following a dose of the DREADD agonist clozapine-N-oxide (CNO. Because DREADD experiments often involve behavioral assays, the method of CNO delivery is important. Currently, the most common delivery method is intraperitoneal (IP injection. IP injection is both a fast and reliable technique, but it is painful and stressful particularly when many injections are required. We sought an alternative CNO delivery paradigm, which would retain the speed and reliability of IP injections without being as invasive. Here, we show that CNO can be effectively delivered topically via eye-drops. Eye-drops robustly activated DREADD-expressing neurons in the brain and peripheral tissues and does so at the same dosages as IP injection. Eye-drops provide an easier, less invasive and less stressful method for activating DREADDs in vivo.

  8. Meta analysis of traditional Chinese medicine in the treatment of dry eye in recent years

    Directory of Open Access Journals (Sweden)

    Peng-Fei Jiang

    2018-06-01

    Full Text Available AIM: To evaluate the traditional Chinese medicine(TCMfor the treatment of dry eye effect in the past five years by using meta analysis method. METHODS: According to the Cochrane evaluation system method, we searched Medline(January 2013 to October 2017, EMbase(2013-2017, Cochrane Library(2017, Wanfang database(2013-2017, VIP(2013-2017, and CNKI(2013-2017for studies published. We included randomized controlled trials conducted the TCM in the treatment of dry eye. RevMan 5.0 statistical software data extraction and Meta analysis were conducted. RESULTS: A total of 10 studies were identified, nine were from Chinese literature and one was from English literature, of which including 1 229 eyes. Nine of these studies performed BUT measurements at the end of the course of treatment. The results showed a statistically significant difference(PPP=0.25. Three studies performed dry eye symptoms after the end of the course of treatment; the results showed that the differences were statistically significant(P=0.0003; the overall efficacy comparison, the difference between the two groups was statistically significant(PCONCLUSION: TCM treatment can significantly prolong BUT and increase tear flow, and has more advantages in the treatment of dry eye.

  9. A new cell-based method for assessing the eye irritation potential of chemicals: an alternative to the Draize test.

    Science.gov (United States)

    Cho, Sun-A; An, Susun; Lee, Eunyoung; Shin, Kyeho; Cho, Jun-Cheol; Lee, Tae Ryong

    2012-07-20

    Using a human corneal cell line (HCE-T cells) and 2 evaluation criteria, we developed a new alternative method to assess the eye irritation potential of chemicals. We exposed HCE-T cells to different concentrations of 38 chemicals for 1h and measured relative cell viability (RCV) as an endpoint at each concentration. Using the RCV values, we calculated the RCV50. We also exposed HCE-T cells to 3 fixed concentrations of the 38 chemicals (5%, 0.5%, and 0.05%) for 1h and measured the RCV at each concentration. Using the RCV values at 5%, 0.5%, and 0.05%, we developed a new criterion for eye irritation potential (total eye irritation score, TEIS) and estimated the ocular irritancy. We then assessed the correlation of the results of RCV50 and TEIS with those of the Draize rabbit eye irritation. Both the RCV50 and TEIS results exhibited good positive correlations (sensitivity: 80.77%, specificity: 83.33%, and accuracy: 81.58% for TEIS; sensitivity: 73.08-76.92%, specificity: 75.00%, and accuracy: 73.68-76.32% for RCV50). We conclude that the new in vitro model using HCE-T cells is a good alternative evaluation model for the prediction of the eye irritation potential of chemicals. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  10. Antibacterial effects of the artificial surface of nanoimprinted moth-eye film.

    Directory of Open Access Journals (Sweden)

    Kiyoshi Minoura

    Full Text Available The antibacterial effect of a nanostructured film, known as "moth-eye film," was investigated. The moth-eye film has artificially formed nano-pillars, consisting of hydrophilic resin with urethane acrylate and polyethylene glycol (PEG derivatives, all over its surface that replicates a moth's eye. Experiments were performed to compare the moth-eye film with a flat-surfaced film produced from the same materials. The JIS Z2801 film-covering method revealed that the two films produced a decrease in Staphylococcus aureus and Esherichia coli titers of over 5 and 3 logs, respectively. There was no marked difference in the antibacterial effects of the two surfaces. However, the antibacterial effects were reduced by immersion of the films in water. These results indicated that a soluble component(s of the resin possessed the antibacterial activity, and this component was identified as PEG derivatives by time-of-flight secondary ion mass spectrometry (TOF-SIMS and Fourier transform infrared spectroscopy (FT-IR. When a small volume of bacterial suspension was dropped on the films as an airborne droplet model, both films showed antibacterial effects, but that of the moth-eye film was more potent. It was considered that the moth-eye structure allowed the bacteria-loaded droplet to spread and allow greater contact between the bacteria and the film surface, resulting in strong adherence of the bacteria to the film and synergistically enhanced bactericidal activity with chemical components. The antibacterial effect of the moth-eye film has been thus confirmed under a bacterial droplet model, and it appears attractive due to its antibacterial ability, which is considered to result not only from its chemical make-up but also from physical adherence.

  11. Eyes Wide Open

    Directory of Open Access Journals (Sweden)

    Zoi Manesi

    2016-04-01

    Full Text Available Research from evolutionary psychology suggests that the mere presence of eye images can promote prosocial behavior. However, the “eye images effect” is a source of considerable debate, and findings across studies have yielded somewhat inconsistent support. We suggest that one critical factor may be whether the eyes really need to be watching to effectively enhance prosocial behavior. In three experiments, we investigated the impact of eye images on prosocial behavior, assessed in a laboratory setting. Participants were randomly assigned to view an image of watching eyes (eyes with direct gaze, an image of nonwatching eyes (i.e., eyes closed for Study 1 and averted eyes for Studies 2 and 3, or an image of flowers (control condition. Upon exposure to the stimuli, participants decided whether or not to help another participant by completing a dull cognitive task. Three independent studies produced somewhat mixed results. However, combined analysis of all three studies, with a total of 612 participants, showed that the watching component of the eyes is important for decision-making in this context. Images of watching eyes led to significantly greater inclination to offer help as compared to images of nonwatching eyes (i.e., eyes closed and averted eyes or images of flowers. These findings suggest that eyes gazing at an individual, rather than any proxy to social presence (e.g., just the eyes, serve as a reminder of reputation. Taken together, we conclude that it is “eyes that pay attention” that can lift the veil of anonymity and potentially facilitate prosocial behavior.

  12. Head-mounted eye tracking of a chimpanzee under naturalistic conditions.

    Directory of Open Access Journals (Sweden)

    Fumihiro Kano

    Full Text Available This study offers a new method for examining the bodily, manual, and eye movements of a chimpanzee at the micro-level. A female chimpanzee wore a lightweight head-mounted eye tracker (60 Hz on her head while engaging in daily interactions with the human experimenter. The eye tracker recorded her eye movements accurately while the chimpanzee freely moved her head, hands, and body. Three video cameras recorded the bodily and manual movements of the chimpanzee from multiple angles. We examined how the chimpanzee viewed the experimenter in this interactive setting and how the eye movements were related to the ongoing interactive contexts and actions. We prepared two experimentally defined contexts in each session: a face-to-face greeting phase upon the appearance of the experimenter in the experimental room, and a subsequent face-to-face task phase that included manual gestures and fruit rewards. Overall, the general viewing pattern of the chimpanzee, measured in terms of duration of individual fixations, length of individual saccades, and total viewing duration of the experimenter's face/body, was very similar to that observed in previous eye-tracking studies that used non-interactive situations, despite the differences in the experimental settings. However, the chimpanzee viewed the experimenter and the scene objects differently depending on the ongoing context and actions. The chimpanzee viewed the experimenter's face and body during the greeting phase, but viewed the experimenter's face and hands as well as the fruit reward during the task phase. These differences can be explained by the differential bodily/manual actions produced by the chimpanzee and the experimenter during each experimental phase (i.e., greeting gestures, task cueing. Additionally, the chimpanzee's viewing pattern varied depending on the identity of the experimenter (i.e., the chimpanzee's prior experience with the experimenter. These methods and results offer new

  13. NMR spectroscopy applied to the eye: Drugs and metabolic studies

    Energy Technology Data Exchange (ETDEWEB)

    Saether, Oddbjoern

    2005-07-01

    NMR spectroscopy has been extensively applied in biomedical research during the last decades. It has proved to be an analytical tool of great value. From being mainly used in chemistry, technological developments have expanded the application of NMR spectroscopy to a great wealth of disciplines. With this method, biochemical information can be obtained by analysing tissue extracts. Moreover, NMR spectroscopy is increasingly employed for pharmacokinetic studies and analysis of biofluids. Technological progress has provided increased sensitivity and resolution in the spectra, which enable even more of the complexity of biological samples to be elucidated. With the implementation of high-resolution magic angle spinning (HR-MAS) NMR spectroscopy in biomedicine, intact tissue samples or biopsies can be investigated. Thus, NMR spectroscopy has an ever-increasing impact in metabolic screening of human samples and in animal models, and methods are also increasingly realised in vivo. The present work, NMR spectroscopy applied to eye research, consists of two main parts. Firstly, the feasibility to monitor fluorinated ophthalmic drugs directly in the eye was assessed. Secondly, HR-MAS H1 NMR spectroscopy was applied for metabolic profiling of the anterior eye segment, specifically to analyse metabolic changes in intact corneal and lenticular samples after cataractogenic insults. This work included metabonomics with the application of pattern recognition methods to analyse HR-MAS spectra of eye tissues. Optimisation strategies were explored for F19 NMR detection of fluorinated drugs in a phantom eye. S/N gains in F19 NMR spectroscopy were achieved by implementing time-share H1 decoupling at 2.35 T. The method is advantageous for compounds displaying broad spectral coupling patterns, though detection of drugs at concentrations encountered in the anterior eye segment after topical application was not feasible. Higher magnetic fields and technological improvements could enable

  14. NMR spectroscopy applied to the eye: Drugs and metabolic studies

    International Nuclear Information System (INIS)

    Saether, Oddbjoern

    2005-01-01

    NMR spectroscopy has been extensively applied in biomedical research during the last decades. It has proved to be an analytical tool of great value. From being mainly used in chemistry, technological developments have expanded the application of NMR spectroscopy to a great wealth of disciplines. With this method, biochemical information can be obtained by analysing tissue extracts. Moreover, NMR spectroscopy is increasingly employed for pharmacokinetic studies and analysis of biofluids. Technological progress has provided increased sensitivity and resolution in the spectra, which enable even more of the complexity of biological samples to be elucidated. With the implementation of high-resolution magic angle spinning (HR-MAS) NMR spectroscopy in biomedicine, intact tissue samples or biopsies can be investigated. Thus, NMR spectroscopy has an ever-increasing impact in metabolic screening of human samples and in animal models, and methods are also increasingly realised in vivo. The present work, NMR spectroscopy applied to eye research, consists of two main parts. Firstly, the feasibility to monitor fluorinated ophthalmic drugs directly in the eye was assessed. Secondly, HR-MAS H1 NMR spectroscopy was applied for metabolic profiling of the anterior eye segment, specifically to analyse metabolic changes in intact corneal and lenticular samples after cataractogenic insults. This work included metabonomics with the application of pattern recognition methods to analyse HR-MAS spectra of eye tissues. Optimisation strategies were explored for F19 NMR detection of fluorinated drugs in a phantom eye. S/N gains in F19 NMR spectroscopy were achieved by implementing time-share H1 decoupling at 2.35 T. The method is advantageous for compounds displaying broad spectral coupling patterns, though detection of drugs at concentrations encountered in the anterior eye segment after topical application was not feasible. Higher magnetic fields and technological improvements could enable

  15. Impact of dry eye on work productivity

    Directory of Open Access Journals (Sweden)

    Yamada M

    2012-10-01

    Full Text Available Masakazu Yamada, Yoshinobu Mizuno, Chika ShigeyasuNational Institute of Sensory Organs, National Hospital Organization Tokyo Medical Center, Tokyo, JapanBackground: The purpose of this study was to evaluate the impact of dry eye on work productivity of office workers, especially in terms of presenteeism.Methods: A total of 396 individuals aged ≥20 years (258 men and 138 women, mean age 43.4 ± 13.0 years were recruited through an online survey. Data from 355 responders who did not have missing values were included in the analysis. They were classified into the following four groups according to the diagnostic status and subjective symptoms of dry eye: a definite dry eye group; a marginal dry eye group; a self-reported dry eye group; and a control group. The impact of dry eye on work productivity was evaluated using the Japanese version of the Work Limitations Questionnaire. The cost of work productivity loss associated with dry eye and the economic benefits of providing treatment for dry eye were also assessed.Results: The degree of work performance loss was 5.65% in the definite dry eye group, 4.37% in the marginal dry eye group, 6.06% in the self-reported dry eye group, and 4.27% in the control group. Productivity in the self-reported dry eye group was significantly lower than that in the control group (P < 0.05. The annual cost of work productivity loss associated with dry eye was estimated to be USD 741 per person.Conclusion: Dry eye impairs work performance among office workers, which may lead to a substantial loss to industry. Management of symptoms of dry eye by providing treatment may contribute to improvement in work productivity.Keywords: burden of disease, dry eye, presenteeism, quality of life

  16. Interim report of the JHPS expert committee on radiation protection of the lens of the eye (2). The dosimetry method for the lens of the eye of workers in Japan

    International Nuclear Information System (INIS)

    Akahane, Keiichi; Tatsuzaki, Hideo; Iimoto, Takeshi; Ichiji, Takeshi; Hamada, Nobuyuki; Fujimichi, Yuki; Iwai, Satoshi; Ohguchi, Hiroyuki; Ohno, Kazuko; Yamauchi, Chiyo; Tsujimura, Norio; Hotta, Yutaka; Yamasaki, Tadashi; Yokoyama, Sumi

    2014-01-01

    A brief review is given of the history and methodology of external dosimetry for the lens of the eye. Under the 1989 revision to domestic radiological protection regulations, the concept on the effective dose equivalent and the dose limit to the lens of the eye (150 mSv/y) both introduced in the ICRP 1977 recommendations has changed nationwide the external monitoring methodology in non-uniform exposure situations to the trunk of a radiological worker. In such situations, which are often created by the presence of a protective apron, the worker is required to use at least two personal dosemeters, one worn on the trunk under the apron and the other, typically, at the collar over the apron. The latter dosemeter serves the dual purpose of providing the dose profile across the trunk for improved effective dose equivalent assessment and of estimating the dose to lens of the eye. The greater or appropriate value between H p (10) and H p (0.07), given by the dosemeter, is generally used as a surrogate of H p (3) for recording the dose to the lens of the eye. The above-mentioned methodology was continued in the latest 2001 revision to the relevant regulations. (author)

  17. Natural history of choroidal neovascularization after surgical induction in an animal model

    DEFF Research Database (Denmark)

    Lassota, Nathan; Kiilgaard, Jens Folke; la Cour, Morten

    2008-01-01

    PURPOSE: To study an expanded time course of surgically induced choroidal neovascularization (CNV) in a porcine model applying fluorescence angiography and immunohistology. METHODS: Twenty-two porcine eyes underwent vitrectomy, a retinal bleb was raised and the detached retina perforated using en...

  18. Reliability of corneal dynamic scheimpflug analyser measurements in virgin and post-PRK eyes.

    Directory of Open Access Journals (Sweden)

    Xiangjun Chen

    Full Text Available PURPOSE: To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK eyes and compare the results between these two groups. METHODS: Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs were calculated. Univariate analysis of covariance (ANCOVA was used to compare measured parameters between virgin and post-PRK eyes. RESULTS: The intraocular pressure (IOP, central corneal thickness (CCT and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC ≧ 0.90 in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC ≧ 0.88. The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, p<0.05 and negatively with deformation amplitude (r = -0.384 and -0.375, respectively, p<0.05 in both groups. Compared to post-PRK eyes, virgin eyes showed longer 1st applanation time (7.29 ± 0.21 vs. 6.96 ± 0.17 ms, p<0.05 and lower deformation amplitude (1.06 ± 0.07 vs. 1.17 ± 0.08 mm, p < 0.05. CONCLUSIONS: CorVis ST demonstrated reliable measurements for CCT, IOP, and 1st applanation time, as well as relatively reliable measurement for deformation amplitude in both virgin and post-PRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter.

  19. Tromsø eye study

    DEFF Research Database (Denmark)

    Bertelsen, Geir; Peto, Tunde; Lindekleiv, Haakon

    2013-01-01

    Purpose:  To determine the prevalence of visual impairment, retinopathy and macular oedema, and assess risk factors for retinopathy in persons with diabetes. Methods:  The present study included 514 participants with diabetes aged 46-87 years from the Tromsø Eye Study, a sub-study of the population......-based Tromsø Study in Norway. Visual acuity was measured using an auto-refractor. Retinal images from both eyes were graded for retinopathy and macular oedema. We collected data on risk factor exposure from self-report questionnaires, clinical examinations, laboratory measurements and case note reviews...

  20. The Twenty Statement Test in Teacher Development

    Directory of Open Access Journals (Sweden)

    Ahmet Aypay

    2011-10-01

    Full Text Available The purpose of this study is to describe teacher characteristics using Twenty Statements Test (TST. Study group includes a total of thirty-five individuals, including teachers, guidance and counselors and research assistants. The study used a qualitative approach on teacher identity. TST is one of the qualitative methods that were used to determine individual self-conceptualization. Study group were requested to write twenty statements that describe themselves responding to the question “Who I am?” in a free format. The findings indicated that teachers were overwhelmingly in group c (reflective. No differences were found in terms of gender and profession. Only few significant differences have been found based on marital status. The utility of TST in teacher training and development was discussed.

  1. The Twenty Statement Test in Teacher Development

    Directory of Open Access Journals (Sweden)

    Ahmet Aypay

    2011-04-01

    Full Text Available The purpose of this study is to describe teacher characteristics using Twenty Statements Test (TST. Study group includes a total of thirty-five individuals, including teachers, guidance and counselors and research assistants. The study used a qualitative approach on teacher identity. TST is one of the qualitative methods that were used to determine individual self-conceptualization. Study group were requested to write twenty statements that describe themselves responding to the question “Who I am?” in a free format. The findings indicated that teachers were overwhelmingly in group c (reflective. No differences were found in terms of gender and profession. Only few significant differences have been found based on marital status. The utility of TST in teacher training and development was discussed

  2. An Interactive Method for Teaching Anatomy of the Human Eye for Medical Students in Ophthalmology Clinical Rotations

    Science.gov (United States)

    Kivell, Tracy L.; Doyle, Sara K.; Madden, Richard H.; Mitchell, Terry L.; Sims, Ershela L.

    2009-01-01

    Much research has shown the benefits of additional anatomical learning and dissection beyond the first year of medical school human gross anatomy, all the way through postgraduate medical training. We have developed an interactive method for teaching eye and orbit anatomy to medical students in their ophthalmology rotation at Duke University…

  3. Multimodal imaging of ocular surface of dry eye subjects

    Science.gov (United States)

    Zhang, Aizhong; Salahura, Gheorghe; Kottaiyan, Ranjini; Yoon, Geunyoung; Aquavella, James V.; Zavislan, James M.

    2016-03-01

    To study the relationship between the corneal lipid layer and the ocular surface temperature (OST), we conducted a clinical trial for 20 subjects. Subjects were clinically screened prior to the trial. Of the 20 subjects, 15 have Meibomian gland dysfunction (MGD), and 5 have aqueous-deficient dry eye (ADDE). A custom, circularly polarized illumination video tearscope measured the lipid layer thickness of the ocular tear film. A long-wave infrared video camera recorded the dynamic thermal properties of the ocular team film. The results of these two methods were analyzed and compared. Using principal component analysis (PCA) of the lipid layer distribution, we find that the 20 subjects could be categorized into five statistically significant groups, independent of their original clinical classification: thin (6 subjects), medium (5 subjects), medium and homogenous (3 subjects), thick (4 subjects), and very thick (2 subjects) lipids, respectively. We also conducted PCA of the OST data, and recategorized the subjects into two thermal groups by k-means clustering: one includes all ADDE subjects and some MGD subjects; the other includes the remaining MGD subjects. By comparing these two methods, we find that dry eye subjects with thin ( 40 nm), there is no strong correlation between the lipid layer thickness and heterogeneity and the OST patterns.

  4. Toxicity of twenty-two plant essential oils against pathogenic bacteria of vegetables and mushrooms.

    Science.gov (United States)

    Todorović, Biljana; Potočnik, Ivana; Rekanović, Emil; Stepanović, Miloš; Kostić, Miroslav; Ristić, Mihajlo; Milijašević-Marčić, Svetlana

    2016-12-01

    ASBTRACT Toxicity of twenty-two essential oils to three bacterial pathogens in different horticultural systems: Xanthomonas campestris pv. phaseoli (causing blight of bean), Clavibacter michiganensis subsp. michiganensis (bacterial wilt and canker of tomato), and Pseudomonas tolaasii (causal agent of bacterial brown blotch on cultivated mushrooms) was tested. Control of bacterial diseases is very difficult due to antibiotic resistance and ineffectiveness of chemical products, to that essential oils offer a promising alternative. Minimal inhibitory and bactericidal concentrations are determined by applying a single drop of oil onto the inner side of each plate cover in macrodilution assays. Among all tested substances, the strongest and broadest activity was shown by the oils of wintergreen (Gaultheria procumbens), oregano (Origanum vulgare), and lemongrass (Cymbopogon flexuosus. Carvacrol (64.0-75.8%) was the dominant component of oregano oils, while geranial (40.7%) and neral (26.7%) were the major constituents of lemongrass oil. Xanthomonas campestris pv. phaseoli was the most sensitive to plant essential oils, being susceptible to 19 oils, while 11 oils were bactericidal to the pathogen. Sixteen oils inhibited the growth of Clavibacter michiganensis subsp. michiganensis and seven oils showed bactericidal effects to the pathogen. The least sensitive species was Pseudomonas tolaasii as five oils inhibited bacterial growth and two oils were bactericidal. Wintergreen, oregano, and lemongrass oils should be formulated as potential biochemical bactericides against different horticultural pathogens.

  5. Comparison of postoperative corneal changes between dry eye and non-dry eye in a murine cataract surgery model.

    Science.gov (United States)

    Kwon, Jin Woo; Chung, Yeon Woong; Choi, Jin A; La, Tae Yoon; Jee, Dong Hyun; Cho, Yang Kyung

    2016-01-01

    To compare the effects of the surgical insult of cataract surgery on corneal inflammatory infiltration, neovascularization (NV) and lymphangiogenesis (LY) between the dry eye and non-dry eye in murine cataract surgery models. We established two groups of animals, one with normal eyes (non-dry eye) and the second with induced dry eyes. In both groups, we used surgical insults to mimic human cataract surgery, which consisted of lens extraction, corneal incision and suture. After harvesting of corneas on the 9(th) postoperative day and immunohistochemical staining, we compared NV, LY and CD11b+ cell infiltration in the corneas. Dry eye group had significantly more inflammatory infiltration (21.75%±7.17% vs 3.65%±1.49%; P=0.049). The dry eye group showed significantly more NV (48.21%±4.02% vs 26.24%±6.01%; P=0.016) and greater levels of LY (9.27%±0.48% vs 4.84%±1.15%; P=0.007). In corneas on which no surgery was performed, there was no induction of NV in both the dry and non-dry group, but dry eye group demonstrated more CD11b+ cells infiltration than the non-dry eye group (0.360%±0.160% vs 0.023%±0.006%; P=0.068). Dry eye group showed more NV than non-dry eye group in both topical PBS application and subconjunctival PBS injection (P=0.020 and 0.000, respectively). In a murine cataract surgery model, preexisting dry eye can induce more postoperative NV, LY, and inflammation in corneal tissue.

  6. Fast cat-eye effect target recognition based on saliency extraction

    Science.gov (United States)

    Li, Li; Ren, Jianlin; Wang, Xingbin

    2015-09-01

    Background complexity is a main reason that results in false detection in cat-eye target recognition. Human vision has selective attention property which can help search the salient target from complex unknown scenes quickly and precisely. In the paper, we propose a novel cat-eye effect target recognition method named Multi-channel Saliency Processing before Fusion (MSPF). This method combines traditional cat-eye target recognition with the selective characters of visual attention. Furthermore, parallel processing enables it to achieve fast recognition. Experimental results show that the proposed method performs better in accuracy, robustness and speed compared to other methods.

  7. Twenty-First Century Literacy: A Matter of Scale from Micro to Mega

    Science.gov (United States)

    Brown, Abbie; Slagter van Tryon, Patricia J.

    2010-01-01

    Twenty-first century technologies require educators to look for new ways to teach literacy skills. Current communication methods are combinations of traditional and newer, network-driven forms. This article describes the changes twenty-first century technologies cause in the perception of time, size, distance, audience, and available data, and…

  8. Clinical effect of vitamin A palmitate eye gel on early ocular surface reconstruction after thermal or chemical injuries

    Directory of Open Access Journals (Sweden)

    Fen-Dui Zhang

    2015-11-01

    Full Text Available AIM: To evaluate the clinical effect of vitamin A palmitate eye gel on early ocular surface reconstruction after thermal or chemical injuries. METHODS: Seventy-eight cases with thermal or chemical injuries to eyes were selected and divided into two groups by randomized, double-blind, positive drug parallel controlled method: group A(40 cases were treated with vitamin A palmitate eye geland group B \\〖38 cases were treated with basic fibroblast growth factor(bFGF\\〗. The bFGF and vitamin A palmitate eye gel were used 4 times a day. The treatment course was 14d. Restoration of epithelial defect, Schirmer's test values, tear break-up time(BUT, and subjective assessment of symptoms and signs were observed on D1, D3, D5, D7, D10 and D14.RESULTS: In group A, 31 cases were cured, 5 cases were effective, with the cure rate of 76% and efficiency 90%. In group B, 32 cases were cured, 3 cases were effective, with the cure rate of 84% and efficiency 92%. There were no significant differences between the two groups(P>0.05. However, there were significant differences on the results of Schirmer's test and BUT(PPCONCLUSION: Vitamin A palmitate eye gel is valuable and safe on early ocular surface reconstruction of the eyes suffered from thermal or chemical injuries.

  9. Novel shadowless imaging for eyes-like diagnosis in vivo

    Science.gov (United States)

    Xue, Ning; Jiang, Kai; Li, Qi; Zhang, Lili; Ma, Li; Huang, Guoliang

    2016-10-01

    Eyes-like diagnosis was a traditional Chinese medicine method for many diseases, such as chronic gastritis, diabetes, hypertension etc. There was a close relationship between viscera and eyes-like. White-Eye was divided into fourteen sections, which corresponded to different viscera, so eyes-like was the reflection of status of viscera, in another words, it was an epitome of viscera health condition. In this paper, we developed a novel shadowless imaging technology and system for eyes-like diagnosis in vivo, which consisted of an optical shadowless imaging device for capturing and saving images of patients' eyes-like, and a computer linked to the device for image processing. A character matching algorithm was developed to extract the character of white-eye in corresponding sections of eyes-like images taken by the optical shadowless imaging device, according to the character of eyes-like, whether there were viscera diseases could be learned. A series of assays were carried out, and the results verified the feasibility of eyes-like diagnosis technique.

  10. A novel strong tracking finite-difference extended Kalman filter for nonlinear eye tracking

    Institute of Scientific and Technical Information of China (English)

    ZHANG ZuTao; ZHANG JiaShu

    2009-01-01

    Non-Intrusive methods for eye tracking are Important for many applications of vision-based human computer interaction. However, due to the high nonlinearity of eye motion, how to ensure the robust-ness of external interference and accuracy of eye tracking poses the primary obstacle to the integration of eye movements into today's interfaces. In this paper, we present a strong tracking finite-difference extended Kalman filter algorithm, aiming to overcome the difficulty In modeling nonlinear eye tracking. In filtering calculation, strong tracking factor is introduced to modify a priori covariance matrix and im-prove the accuracy of the filter. The filter uses finite-difference method to calculate partial derivatives of nonlinear functions for eye tracking. The latest experimental results show the validity of our method for eye tracking under realistic conditions.

  11. [Ablation on the undersurface of a LASIK flap. Instrument and method for continuous eye tracking].

    Science.gov (United States)

    Taneri, S; Azar, D T

    2007-02-01

    The risk of iatrogenic keratectasia after laser in situ keratomileusis (LASIK) increases with thinner posterior stromal beds. Ablations on the undersurface of a LASIK flap could only be performed without the guidance of an eye tracker, which may lead to decentration. A new method for laser ablation with flying spot lasers on the undersurface of a LASIK flap was developed that enables the use of an active eye tracker by utilizing a novel instrument. The first clinical results are reported. Patients wishing an enhancement procedure were eligible for a modified repeat LASIK procedure if the flaps cut in the initial procedure were thick enough to perform the intended additional ablation on the undersurface leaving at least 90 microm of flap thickness behind. (1) The horizontal axis and the center of the entrance pupil were marked on the epithelial side of the flap using gentian violet dye. (2) The flap was reflected on a newly designed flap holder which had a donut-shaped black marking. (3) The eye tracker was centered on the mark visible in transparency on the flap. (4) Ablation with a flying spot Bausch & Lomb Technolas 217z laser was performed on the undersurface of the flap with a superior hinge taking into account that in astigmatic ablations the cylinder axis had to be mirrored according to the formula: axis on the undersurface=180 degrees -axis on the stromal bed. (5) The flap was repositioned. Detection of the marking on the modified flap holder and continuous tracking instead of the real pupil was possible in all of the 12 eyes treated with this technique. It may be necessary to cover the real pupil during ablation in order not to confuse the eye tracker. Ablation could be performed without decentration or loss of best spectacle-corrected visual acuity. Refractive results in minor corrections were good without nomogram adjustment. Using this novel flap holder with a marking that is tracked instead of the real pupil, centered ablations with a flying spot laser

  12. Change in convergence and accommodation after two weeks of eye exercises in typical young adults.

    Science.gov (United States)

    Horwood, Anna M; Toor, Sonia S; Riddell, Patricia M

    2014-04-01

    Although eye exercises appear to help heterophoria, convergence insufficiency, and intermittent strabismus, results can be confounded by placebo, practice, and encouragement effects. This study assessed objective changes in vergence and accommodation responses in naive young adults after a 2-week period of eye exercises under controlled conditions to determine the extent to which treatment effects occur over other factors. Asymptomatic young adults were randomly assigned to one of two no-treatment (control) groups or to one of six eye exercise groups: accommodation, vergence, both, convergence in excess of accommodation, accommodation in excess of convergence, and placebo. Subjects were tested and retested under identical conditions, except for the second control group, who were additionally encouraged. Objective accommodation and vergence were assessed to a range of targets moving in depth containing combinations of blur, disparity, and proximity/looming cues. A total of 156 subjects were included. Response gain improved more for less naturalistic targets where more improvement was possible. Convergence exercises improved vergence for near across all targets (P = 0.035). Mean accommodation changed similarly but nonsignificantly. No other treatment group differed significantly from the nonencouraged control group, whereas encouraging effort produced significantly increased vergence (P = 0.004) and accommodation (P = 0.005) gains in the second control group. True treatment effects were small, significantly better only after vergence exercises to a nonaccommodative target, and rarely related to the response they were designed to improve. Exercising accommodation without convergence made no difference to accommodation to cues containing detail. Additional effort improved objective responses the most. Copyright © 2014 American Association for Pediatric Ophthalmology and Strabismus. Published by Mosby, Inc. All rights reserved.

  13. An Integrative Model for the Neural Mechanism of Eye Movement Desensitization and Reprocessing (EMDR)

    OpenAIRE

    Coubard, Olivier A.

    2016-01-01

    Since the seminal report by Shapiro that bilateral stimulation induces cognitive and emotional changes, twenty-six years of basic and clinical research have examined the effects of Eye Movement Desensitization and Reprocessing (EMDR) in anxiety disorders, particularly in Post-Traumatic Stress Disorder (PTSD). The present article aims at better understanding EMDR neural mechanism. I first review procedural aspects of EMDR protocol and theoretical hypothesis about EMDR effects, and develop the ...

  14. Microbiological Safety of Commercial Prime Rib Preparation Methods: Thermal Inactivation of Salmonella in Mechanically Tenderized Rib Eye.

    Science.gov (United States)

    Calle, Alexandra; Porto-Fett, Anna C S; Shoyer, Bradley A; Luchansky, John B; Thippareddi, Harshavardhan

    2015-12-01

    Boneless beef rib eye roasts were surface inoculated on the fat side with ca. 5.7 log CFU/g of a five-strain cocktail of Salmonella for subsequent searing, cooking, and warm holding using preparation methods practiced by restaurants surveyed in a medium-size Midwestern city. A portion of the inoculated roasts was then passed once through a mechanical blade tenderizer. For both intact and nonintact roasts, searing for 15 min at 260°C resulted in reductions in Salmonella populations of ca. 0.3 to 1.3 log CFU/g. For intact (nontenderized) rib eye roasts, cooking to internal temperatures of 37.8 or 48.9°C resulted in additional reductions of ca. 3.4 log CFU/g. For tenderized (nonintact) rib eye roasts, cooking to internal temperatures of 37.8 or 48.9°C resulted in additional reductions of ca. 3.1 or 3.4 log CFU/g, respectively. Pathogen populations remained relatively unchanged for intact roasts cooked to 37.8 or 48.9°C and for nonintact roasts cooked to 48.9°C when held at 60.0°C for up to 8 h. In contrast, pathogen populations increased ca. 2.0 log CFU/g in nonintact rib eye cooked to 37.8°C when held at 60.0°C for 8 h. Thus, cooking at low temperatures and extended holding at relatively low temperatures as evaluated herein may pose a food safety risk to consumers in terms of inadequate lethality and/or subsequent outgrowth of Salmonella, especially if nonintact rib eye is used in the preparation of prime rib, if on occasion appreciable populations of Salmonella are present in or on the meat, and/or if the meat is not cooked adequately throughout.

  15. EyeGENE

    Data.gov (United States)

    U.S. Department of Health & Human Services — The eyeGENE® Biorepository and corresponding Database contain family history and clinical eye exam data from subjects enrolled in eyeGENE® Program coupled to...

  16. In the twinkling of an eye: synchronization of EEG and eye tracking based on blink signatures

    DEFF Research Database (Denmark)

    Bækgaard, Per; Petersen, Michael Kai; Larsen, Jakob Eg

    2014-01-01

    function based algorithm to correlate the signals. Comparing the accuracy of the method against a state of the art EYE-EEG plug-in for offline analysis of EEG and eye tracking data, we propose our approach could be applied for robust synchronization of biometric sensor data collected in a mobile context.......ACHIEVING ROBUST ADAPTIVE SYNCHRONIZATION OF MULTIMODAL BIOMETRIC INPUTS: The recent arrival of wireless EEG headsets that enable mobile real-time 3D brain imaging on smartphones, and low cost eye trackers that provide gaze control of tablets, will radically change how biometric sensors might...... be integrated into next generation user interfaces. In experimental lab settings EEG neuroimaging and eye tracking data are traditionally combined using external triggers to synchronize the signals. However, with biometric sensors increasingly being applied in everyday usage scenarios, there will be a need...

  17. Temporal properties of the lens eyes of the box jellyfish Tripedalia cystophora

    DEFF Research Database (Denmark)

    O'Connor, Megan; Nilsson, Dan-E; Garm, Anders Lydik

    2010-01-01

    Box jellyWsh (Cubomedusae) are visually orientating animals which posses a total of 24 eyes of 4 morphological types; 2 pigment cup eyes (pit eye and slit eye) and 2 lens eyes [upper lens-eye (ule) and lower lens-eye (lle)]. In this study, we use electroretinograms (ERGs) to explore temporal...... properties of the two lens eyes. We Wnd that the ERG of both lens eyes are complex and using sinusoidal Xicker stimuli we Wnd that both lens eyes have slow temporal resolution. The average Xicker fusion frequency (FFF) was found to be approximately 10 Hz for the ule and 8 Hz for the lle. Di......Verences in the FFF and response patterns between the two lens eyes suggest that the ule and lle Wlter information diVerently in the temporal domain and thus are tuned to perform diVerent visual tasks. The data collected in this study support the idea that the visual system of box jellyWsh is a collection of special...

  18. Bags Under Eyes

    Science.gov (United States)

    Bags under eyes Overview Bags under eyes — mild swelling or puffiness under the eyes — are common as you age. With aging, the tissues around your ... space below your eyes, adding to the swelling. Bags under eyes are usually a cosmetic concern and ...

  19. [Cyclorotation of the eye in wavefront-guided LASIK using a static eyetracker with iris recognition].

    Science.gov (United States)

    Kohnen, T; Kühne, C; Cichocki, M; Strenger, A

    2007-01-01

    Centration of the ablation zone decisively influences the result of wavefront-guided LASIK. Cyclorotation of the eye occurs as the patient changes from the sitting position during aberrometry to the supine position during laser surgery and may lead to induction of lower and higher order aberrations. Twenty patients (40 eyes) underwent wavefront-guided LASIK (B&L 217z 100 excimer laser) with a static eyetracker driven by iris recognition (mean preoperative SE: -4.72+/-1.45 D; range: -1.63 to -7.00 D). The iris patterns of the patients' eyes were memorized during aberrometry and after flap creation. The mean absolute value of the measured cyclorotation was -1.5+/-4.2 degrees (range: -11.0 to 6.9 degrees ). The mean cyclorotation was 3.5+/-2.7 masculine (range: 0.1 to 11.0 degrees ). In 65% of all eyes cyclorotation was >2 masculine. A static eyetracker driven by iris recognition demonstrated that cyclorotation of up to 11 degrees may occur in myopic and myopic astigmatic eyes when changing from a sitting to a supine position. Use of static eyetrackers with iris recognition may provide a more precise positioning of the ablation profile as they detect and compensate cyclorotation.

  20. The relief of dry eye signs and symptoms using a combination of lubricants, lid hygiene and ocular nutraceuticals.

    Science.gov (United States)

    Ngo, William; Srinivasan, Sruthi; Houtman, Diane; Jones, Lyndon

    To determine the combined effect of TheraTears ® Lubricant Eye Drops, TheraTears ® SteriLid Eyelid Cleanser, and TheraTears ® Nutrition on dry eye signs and symptoms. This prospective study enrolled 28 dry eye participants. Participants were instructed to use the Lubricant Eye Drops at least 2-4× a day, SteriLid 1-2× a day, and Nutrition 3 gel caps once a day. Participants were followed up at baseline, 1 month and 3 months. Outcome variables were the Ocular Surface Disease Index (OSDI), Symptom Assessment iN Dry Eye (SANDE) questionnaire, non-invasive tear break-up time (NIBUT), osmolarity, number of meibomian glands blocked (#MG blocked), meibum quality, eyelid margin features, Schirmer's test, tear film lipid layer thickness (LLT), meniscus height, corneal and conjunctival staining. Twenty participants (mean age=43, from 23 to 66, 17F, 3M) completed the study. Participants reported having used, on average, the Lubricant Eye Drop 2.4×/day, the SteriLid 1.1×/day, and the Nutrition 3 gel caps 1×/day. There was a significant change over time (pEye Drop, SteriLid, and Nutrition, patients experience significant relief in both dry eye symptoms and signs. Copyright © 2016 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.

  1. Lenses matching of compound eye for target positioning

    Science.gov (United States)

    Guo, Fang; Zheng, Yan Pei; Wang, Keyi

    2012-10-01

    Compound eye, as a new imaging method with multi-lens for a large field of view, could complete target positioning and detection fastly, especially at close range. Therefore it could be applicated in the fields of military and medical treatment and aviation with vast market potential and development prospect. Yet the compound eye imaging method designed use three layer construction of multiple lens array arranged in a curved surface and refractive lens and imaging sensor of CMOS. In order to simplify process structure and increase the imaging area of every sub-eye, the imaging area of every eye is coved with the whole CMOS. Therefore, for several imaging point of one target, the corresponding lens of every imaging point is unkonown, and thus to identify. So an algorithm was put forward. Firstly, according to the Regular Geometry relationship of several adjacent lenses, data organization of seven lenses with a main lens was built. Subsequently, by the data organization, when one target was caught by several unknown lenses, we search every combined type of the received lenses. And for every combined type, two lenses were selected to combine and were used to calculate one three-dimensional (3D) coordinate of the target. If the 3D coordinates are same to the some combine type of the lenses numbers, in theory, the lenses and the imaging points are matched. So according to error of the 3D coordinates is calculated by the different seven lenses numbers combines, the unknown lenses could be distinguished. The experimental results show that the presented algorithm is feasible and can complete matching task for imaging points and corresponding lenses.

  2. Structural and functional changes in corneal innervation after laser in situ keratomileusis and their relationship with dry eye.

    Science.gov (United States)

    Chao, Cecilia; Stapleton, Fiona; Zhou, Xiangtian; Chen, Shihao; Zhou, Shi; Golebiowski, Blanka

    2015-11-01

    The most likely etiology of post-LASIK dry eye is corneal nerve damage; however, no direct relationship between post-LASIK dry eye symptoms and nerve damage has been established, and limited information is available about the relationship between dry eye signs and corneal reinnervation after LASIK. Tear neuropeptides (SP and CGRP) are important in the maintenance of corneal nerve health, but the impact of LASIK has not yet been studied. This study evaluated changes in nerve morphology, tear neuropeptide, and dry eye, so as to establish the relationship between reinnervation and dry eye and to assess the role of tear neuropeptides in reinnervation post-LASIK. Twenty non-dry eye volunteers who had undergone bilateral myopic-LASIK completed this study. Corneal nerve morphology (density, width, interconnections, and tortuosity), SP and CGRP concentration, and dry eye were monitored over time prior to, 1 day, 1 week, 1, 3, and 6 months post-LASIK. Dry eye symptoms and tear function, except for osmolarity (P = 0.003), remained unchanged post-LASIK. Corneal nerve morphology decreased immediately, and did not return to preoperative levels by 6 months post-LASIK (P dry eye symptoms (P = 0.01) were found post-LASIK. An inverse relationship between reinnervation post-LASIK and dry eye symptoms was found, confirming that post-LASIK dry eye is a neuropathic disease. This study is the first to demonstrate an association between tear SP and post-LASIK reinnervation, suggesting that strategies for manipulating neuropeptide concentration to improve reinnervation may improve ocular comfort post-LASIK.

  3. Biometric recognition via texture features of eye movement trajectories in a visual searching task.

    Science.gov (United States)

    Li, Chunyong; Xue, Jiguo; Quan, Cheng; Yue, Jingwei; Zhang, Chenggang

    2018-01-01

    Biometric recognition technology based on eye-movement dynamics has been in development for more than ten years. Different visual tasks, feature extraction and feature recognition methods are proposed to improve the performance of eye movement biometric system. However, the correct identification and verification rates, especially in long-term experiments, as well as the effects of visual tasks and eye trackers' temporal and spatial resolution are still the foremost considerations in eye movement biometrics. With a focus on these issues, we proposed a new visual searching task for eye movement data collection and a new class of eye movement features for biometric recognition. In order to demonstrate the improvement of this visual searching task being used in eye movement biometrics, three other eye movement feature extraction methods were also tested on our eye movement datasets. Compared with the original results, all three methods yielded better results as expected. In addition, the biometric performance of these four feature extraction methods was also compared using the equal error rate (EER) and Rank-1 identification rate (Rank-1 IR), and the texture features introduced in this paper were ultimately shown to offer some advantages with regard to long-term stability and robustness over time and spatial precision. Finally, the results of different combinations of these methods with a score-level fusion method indicated that multi-biometric methods perform better in most cases.

  4. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Español Eye Health / Eye Health A-Z Dry Eye Sections What Is Dry Eye? Dry Eye Symptoms ... Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué es el ojo seco? ...

  5. Preservation of enucleated porcine eyes for use in a wet laboratory

    NARCIS (Netherlands)

    Nibourg, Lisanne M.; Koopmans, Steven A.

    PURPOSE: To design a method to preserve enucleated porcine eyes for use in a wet laboratory. SETTING: Laboratory of Experimental Ophthalmology, University Medical Center Groningen, the Netherlands. DESIGN: Experimental study. METHODS: Porcine eyes were preserved using 15 methods including salt

  6. Robustifying eye interaction

    DEFF Research Database (Denmark)

    Hansen, Dan Witzner; Hansen, John Paulin

    2006-01-01

    This paper presents a gaze typing system based on consumer hardware. Eye tracking based on consumer hardware is subject to several unknown factors. We propose methods using robust statistical principles to accommodate uncertainties in image data as well as in gaze estimates to improve accuracy. We...

  7. Danish Rural Eye Study

    DEFF Research Database (Denmark)

    Høeg, Tracy B; Moldow, Birgitte; Ellervik, Christina

    2015-01-01

    and older from a Danish rural municipality received a complete general health examination and an ophthalmological interview and examination. This study included a comprehensive ophthalmologic interview, measurement of best corrected visual acuity (BCVA) in each eye, Hirschberg's test for strabismus and two...... 45-degree retinal fundus photographs of each eye. A complete ophthalmologic examination was performed when indicated. RESULTS: The prevalence of monocular visual impairment (MVI) was 4.26% (95% CI, 3.66-4.95, n = 163). Amblyopia was the most common cause, accounting for 33%. The prevalence...

  8. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Stories Español Eye Health / Eye Health A-Z Dry Eye Sections What Is Dry Eye? Dry Eye Symptoms ... of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué es el ojo seco? ...

  9. The oculomotor system of decapod cephalopods: eye muscles, eye muscle nerves, and the oculomotor neurons in the central nervous system.

    Science.gov (United States)

    Budelmann, B U; Young, J Z

    1993-04-29

    Fourteen extraocular eye muscles are described in the decapods Loligo and Sepioteuthis, and thirteen in Sepia; they are supplied by four eye muscle nerves. The main action of most of the muscles is a linear movement of the eyeball, only three muscles produce strong rotations. The arrangement, innervation and action of the decapod eye muscles are compared with those of the seven eye muscles and seven eye muscle nerves in Octopus. The extra muscles in decapods are attached to the anterior and superior faces of the eyes. At least, the anterior muscles, and presumably also the superior muscles, are concerned with convergent eye movements for binocular vision during fixation and capture of prey by the tentacles. The remaining muscles are rather similar in the two cephalopod groups. In decapods, the anterior muscles include conjunctive muscles; these cross the midline and each presumably moves both eyes at the same time during fixation. In the squids Loligo and Sepioteuthis there is an additional superior conjunctive muscle of perhaps similar function. Some of the anterior muscles are associated with a narrow moveable plate, the trochlear cartilage; it is attached to the eyeball by trochlear membranes. Centripetal cobalt fillings showed that all four eye muscle nerves have fibres that originate from somata in the ipsilateral anterior lateral pedal lobe, which is the oculomotor centre. The somata of the individual nerves show different but overlapping distributions. Bundles of small presumably afferent fibres were seen in two of the four nerves. They do not enter the anterior lateral pedal lobe but run to the ventral magnocellular lobe; some afferent fibres enter the brachio-palliovisceral connective and run perhaps as far as the palliovisceral lobe.

  10. About the Eye

    Medline Plus

    Full Text Available ... Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun Stuff Cool Eye Tricks Links to More Information Optical Illusions Printables About the Eye Your eyes ...

  11. Automatic removal of eye-movement and blink artifacts from EEG signals.

    Science.gov (United States)

    Gao, Jun Feng; Yang, Yong; Lin, Pan; Wang, Pei; Zheng, Chong Xun

    2010-03-01

    Frequent occurrence of electrooculography (EOG) artifacts leads to serious problems in interpreting and analyzing the electroencephalogram (EEG). In this paper, a robust method is presented to automatically eliminate eye-movement and eye-blink artifacts from EEG signals. Independent Component Analysis (ICA) is used to decompose EEG signals into independent components. Moreover, the features of topographies and power spectral densities of those components are extracted to identify eye-movement artifact components, and a support vector machine (SVM) classifier is adopted because it has higher performance than several other classifiers. The classification results show that feature-extraction methods are unsuitable for identifying eye-blink artifact components, and then a novel peak detection algorithm of independent component (PDAIC) is proposed to identify eye-blink artifact components. Finally, the artifact removal method proposed here is evaluated by the comparisons of EEG data before and after artifact removal. The results indicate that the method proposed could remove EOG artifacts effectively from EEG signals with little distortion of the underlying brain signals.

  12. Multifocal Visual Evoked Potential in Eyes With Temporal Hemianopia From Chiasmal Compression: Correlation With Standard Automated Perimetry and OCT Findings.

    Science.gov (United States)

    Sousa, Rafael M; Oyamada, Maria K; Cunha, Leonardo P; Monteiro, Mário L R

    2017-09-01

    To verify whether multifocal visual evoked potential (mfVEP) can differentiate eyes with temporal hemianopia due to chiasmal compression from healthy controls. To assess the relationship between mfVEP, standard automated perimetry (SAP), and Fourier domain-optical coherence tomography (FD-OCT) macular and peripapillary retinal nerve fiber layer (RNFL) thickness measurements. Twenty-seven eyes with permanent temporal visual field (VF) defects from chiasmal compression on SAP and 43 eyes of healthy controls were submitted to mfVEP and FD-OCT scanning. Multifocal visual evoked potential was elicited using a stimulus pattern of 60 sectors and the responses were averaged for the four quadrants and two hemifields. Optical coherence tomography macular measurements were averaged in quadrants and halves, while peripapillary RNFL thickness was averaged in four sectors around the disc. Visual field loss was estimated in four quadrants and each half of the 24-2 strategy test points. Multifocal visual evoked potential measurements in the two groups were compared using generalized estimated equations, and the correlations between mfVEP, VF, and OCT findings were quantified. Multifocal visual evoked potential-measured temporal P1 and N2 amplitudes were significantly smaller in patients than in controls. No significant difference in amplitude was observed for nasal parameters. A significant correlation was found between mfVEP amplitudes and temporal VF loss, and between mfVEP amplitudes and the corresponding OCT-measured macular and RNFL thickness parameters. Multifocal visual evoked potential amplitude parameters were able to differentiate eyes with temporal hemianopia from controls and were significantly correlated with VF and OCT findings, suggesting mfVEP is a useful tool for the detection of visual abnormalities in patients with chiasmal compression.

  13. Eye injury treatment in intensive care unit patients

    Directory of Open Access Journals (Sweden)

    L. K. Moshetova

    2015-01-01

    Full Text Available Aim. To describe eye injuries in intensive care unit (ICU patients with multitrauma, to study conjunctival microflora in these patients, and to develop etiologically and pathogenically targeted treatment and prevention of wound complications.Materials and methods. Study group included 50 patients (54 eyes with combined mechanical cerebral and eye injury. All patients underwent possible ophthalmological examination (biomicroscopy, ophthalmoscopy and ocular fundus photographing with portative fundus camera, tonometry, cranial CT and MRT, and bacteriological study of conjunctival smears. Results. Modern methods of ophthalmological examination of ICU patients provided correct diagnosis and prediction of wound healing. Eye injury treatment schedule provided maximum possible results in all ICU patients. Hospitalacquired infection results in asymptomatic dissemination of pathogenic microbes on ocular surface. Conclusions. 14-day topical treatment with antimicrobials, steroids, and NSAIDs reduces posttraumatic inflammation caused by mechanical eye injuries in ICU patients. Bacteriological studies of conjunctival smears demonstrate the presence of pathogenic flora in ICU patients. In these patients, the most effective antibacterial agents are third-generation fluoroquinolones. 

  14. Eye Care Professionals' Perspectives on Eye Donation and an Eye Donation Registry for Research: A Single-Institution, Cross-Sectional Study.

    Science.gov (United States)

    Williams, Andrew M; Allingham, R Rand; Stamer, W Daniel; Muir, Kelly W

    2016-06-01

    A centralized eye donation registry for research could help to bridge the gap between patients interested in donating their eyes to science and scientists who conduct research on human eye tissue. Previous research has demonstrated patient and family support for such a registry. In this study, we assessed the views that eye care professionals have toward an eye donation registry for research. Surveys were distributed to all 46 clinical faculty members of the Duke University Eye Center. In addition to collecting demographic information, the surveys assessed clinicians' experience with discussing eye donation with patients, described the proposed eye donation registry for research and asked how the registry would affect the clinicians' practice. A total of 21 eye care professionals returned the survey. Thirty-three percent reported discussing eye donation with patients, and 43% reported that a patient has asked about donating their eyes for research on their disease. Eighty-six percent of eye care professionals reported that a centralized registry would improve the way they work with patients who express a desire to donate their eyes for research. The majority of eye care professionals at our academic institution indicated that an eye donation registry for research would improve how they work with patients who are interested in donating their eyes for research on their disease. Future research should examine how best to communicate this registry to ophthalmic patients.

  15. Automatic measurement of axial length of human eye using three-dimensional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Watanabe, Masaki; Kiryu, Tohru

    2011-01-01

    The measurement of axial length and the evaluation of three dimensional (3D) form of an eye are essential to evaluate the mechanism of myopia progression. We propose a method of automatic measurement of axial length including adjustment of the pulse sequence of short-term scan which could suppress influence of eyeblink, using a magnetic resonance imaging (MRI) which acquires 3D images noninvasively. Acquiring T 2 -weighted images with 3.0 tesla MRI device and eight-channel phased-array head coil, we extracted left and right eye ball images, and then reconstructed 3D volume. The surface coordinates were calculated from 3D volume, fitting the ellipsoid model coordinates with the surface coordinates, and measured the axial length automatically. Measuring twenty one subjects, we compared the automatically measured values of axial length with the manually measured ones, then confirmed significant elongation in the axial length of myopia compared with that of emmetropia. Furthermore, there were no significant differences (P<0.05) between the means of automatic measurements and the manual ones. Accordingly, the automatic measurement process of axial length could be a tool for the elucidation of the mechanism of myopia progression, which would be suitable for evaluating the axial length easily and noninvasively. (author)

  16. The highly myopic eye--oculometric considerations

    DEFF Research Database (Denmark)

    Fledelius, Hans C; Goldschmidt, Ernst

    2012-01-01

    (n=39) in 1962. Clinical follow-up studies were conducted in 1976, 1986, 1995 and 2002, with A-scan ultrasound oculometry (Kretztechnik 7000, immersion method; and Sonometrics 400, contact method) as a regular part of the schedule. For comparison, IOL Master evaluations were added in 2002...... by Francois and Goes, not all long eyes have flat corneas. In our high myopia series, a significant subgroup could thus be discerned who had peaked corneas, which led to mathematically slight reduction of the usual positive correlation between axial length and curvature radius in the ametropia population......; and (d) we found positive correlation between myopia increase in adult age and axial elongation, stressing that, in contrast to other outgrown body structures, the adult eye globes may still expand in size. This feature seems to be found not only in the eyes with posterior staphyloma, but also in myopic...

  17. Automated quantification of optic nerve axons in primate glaucomatous and normal eyes--method and comparison to semi-automated manual quantification.

    Science.gov (United States)

    Reynaud, Juan; Cull, Grant; Wang, Lin; Fortune, Brad; Gardiner, Stuart; Burgoyne, Claude F; Cioffi, George A

    2012-05-01

    To describe an algorithm and software application (APP) for 100% optic nerve axon counting and to compare its performance with a semi-automated manual (SAM) method in optic nerve cross-section images (images) from normal and experimental glaucoma (EG) nonhuman primate (NHP) eyes. ON cross sections from eight EG eyes from eight NHPs, five EG and five normal eyes from five NHPs, and 12 normal eyes from 12 NHPs were imaged at 100×. Calibration (n = 500) and validation (n = 50) image sets ranging from normal to end-stage damage were assembled. Correlation between APP and SAM axon counts was assessed by Deming regression within the calibration set and a compensation formula was generated to account for the subtle, systematic differences. Then, compensated APP counts for each validation image were compared with the mean and 95% confidence interval of five SAM counts of the validation set performed by a single observer. Calibration set APP counts linearly correlated to SAM counts (APP = 10.77 + 1.03 [SAM]; R(2) = 0.94, P < 0.0001) in normal to end-stage damage images. In the validation set, compensated APP counts fell within the 95% confidence interval of the SAM counts in 42 of the 50 images and were within 12 axons of the confidence intervals in six of the eight remaining images. Uncompensated axon density maps for the normal and EG eyes of a representative NHP were generated. An APP for 100% ON axon counts has been calibrated and validated relative to SAM counts in normal and EG NHP eyes.

  18. Analysis of the correlation between tear film changes of allergic conjunctivitis and dry eye

    Directory of Open Access Journals (Sweden)

    Yong Li

    2014-07-01

    Full Text Available AIM: To analyze the correlation between tear film changes of allergic conjunctivitis and dry eye, then provide clinical references for better treatment. METHODS: Fifty patients with allergic conjunctivitis were taken as the observation group, the control group was selected based on 1:1 case control theory, and we chose 50 health volunteers without ocular surface diseases, xerophthalmia and systematic diseases randomly, then fluorescein(FLstaining, break-up time(BUT, Schirner I test(SⅠt, tear meniscus high(TMHand slit-lamp examinations were performed in the two groups. RESULTS: In the observation group, FL, BUT, SIt, TMH of right eyes and left eyes were statistically significant correlated(PPPCONCLUSION: Due to inflammatory mediators participation, allergic conjunctivitis could lead to the stability changes of tear film which cause in dry eye. The stability changes of allergic conjunctivitis correlate to the damage degree of epithelium.

  19. Eye movement instructions modulate motion illusion and body sway with Op Art.

    Science.gov (United States)

    Kapoula, Zoï; Lang, Alexandre; Vernet, Marine; Locher, Paul

    2015-01-01

    Op Art generates illusory visual motion. It has been proposed that eye movements participate in such illusion. This study examined the effect of eye movement instructions (fixation vs. free exploration) on the sensation of motion as well as the body sway of subjects viewing Op Art paintings. Twenty-eight healthy adults in orthostatic stance were successively exposed to three visual stimuli consisting of one figure representing a cross (baseline condition) and two Op Art paintings providing sense of motion in depth-Bridget Riley's Movements in Squares and Akiyoshi Kitaoka's Rollers. Before their exposure to the Op Art images, participants were instructed either to fixate at the center of the image (fixation condition) or to explore the artwork (free viewing condition). Posture was measured for 30 s per condition using a body fixed sensor (accelerometer). The major finding of this study is that the two Op Art paintings induced a larger antero-posterior body sway both in terms of speed and displacement and an increased motion illusion in the free viewing condition as compared to the fixation condition. For body sway, this effect was significant for the Riley painting, while for motion illusion this effect was significant for Kitaoka's image. These results are attributed to macro-saccades presumably occurring under free viewing instructions, and most likely to the small vergence drifts during fixations following the saccades; such movements in interaction with visual properties of each image would increase either the illusory motion sensation or the antero-posterior body sway.

  20. Primary non-Hodgkins lymphoma of eye and adnexa. Effect of method of treatment for prognosis

    Directory of Open Access Journals (Sweden)

    E. E. Grishina

    2013-01-01

    Full Text Available Purpose: To identify predictors of NHL of the vision associated with treatment choice for prognosis of primary non-Hodgkin’s lymphoma eye and adnexa.Methods: A retrospective and prospective study characteristics of the disease in 94 patients with primary lymphoma of the vision. Orbital lymphoma diagnosed in 35 patients (36 %, conjunctival — in 48 patients (52 %, the least damage observed age — 11 patients (12 %. Among the various types of malignant lymphomas morphologic immunological dominated B-cell lymphoma or marginal zone MALT-lymphoma, which were diagnosed in 70 (75 %. Patients were treated with radiation, chemotherapy and combined chemoradiotherapy.Results: During the follow-up period of 1 year to 26 years (median follow-up 5 years of the 94 patients the primary lymphoma of the vision in 22 cases (23 % relapses occurred in a period of 6 months to 10 years (median 2 years. In analyzing the data we found that the 5‑year disease-free survival with radiation therapy, chemotherapy, and combination therapy is the same and is equal to — 70 %.Conclusion: The treatment and monitoring of patients with primary non-Hodgkin’s lymphoma eye and adnexa should be implemented jointly ophthalmologist and oncology. The choice of treatment, with adequate treatment is prescribed, can not be associated with the weather and can not be a predictor of the primary non-Hodgkin’s lymphoma eye and adnexa.

  1. Coping with dry eyes: a qualitative approach.

    Science.gov (United States)

    Yeo, Sharon; Tong, Louis

    2018-01-16

    Dry eye is a common problem that affects many people worldwide, reducing quality of life and impacting daily activities. A qualitative approach often used in medicine and other disciplines is used to evaluate how people with dry eye cope with this impact. Six focus group sessions were conducted at the Singapore National Eye Centre (SNEC), premises of an eye research institute. These focus groups consist of a spectrum of dry eye sufferers (30 women, 8 men, aged 61 ± 11.8 years). Standard methods of coding followed by determination of themes were adhered to. Where classification was difficult, consensus was made between 3 assessors. Audio-recorded transcripts were coded in 10 themes by 3 assessors independently. Four of the themes involved traditional measures such as lid warming, cleansing, lubrication and oral dietary supplements. The other themes discovered were Traditional Chinese Medicine, modification of eye-care habits (e.g. wearing sunglasses), environmental humidity, lifestyle (e.g. sleeping habits), psychological attitude, and lastly sharing and communication. Holistic coping strategies were found to be prominent in dry eye sufferers from these focus groups, and people tend to find personalised ways of coping with the impact of dry eye on daily living.

  2. Eye movements during art appreciation by students taking a photo creation course

    Directory of Open Access Journals (Sweden)

    Chiaki Ishiguro

    2016-07-01

    Full Text Available Previous studies have focused on the differences in the art appreciation process between individuals, and indicated that novice viewers of artworks, in comparison to experts, rarely consider the creation process of the artwork or how this may relate to style. However, behavioral changes in individuals after educational interventions have not been examined. Art education researchers claim that technical knowledge and creation experiences help novice viewers to pay attention to technical features of artwork. Therefore, an artistic photo creation course was designed and conducted to help students acquire techniques and procedural knowledge of photo creation. The present study verified whether students’ viewing strategies during appreciation of photographs changed after the course. Twenty-one students participated in two sessions, viewing the same 12 photographs before and after the course. Based on the analysis of recorded eye movements, the results indicated that the students’ perceptual exploration became more active with photographs containing recognizable subjects (i.e., humans and objects, and their global saccades increased when they viewed classic photography, one of the categories of photography covered in the course. Interview data after the course indicated that students became aware of the technical effects in photographs. These results suggest that students’ viewing strategies may change following a course, as assessed by behavioral measures of eye movements. Further examination is needed to validate this approach to educational effect measurement.

  3. Graves' ophthalmopathy evaluated by infrared eye-movement recordings

    International Nuclear Information System (INIS)

    Feldon, S.E.; Unsoeld, R.

    1982-01-01

    Thirteen patients with varying degrees of Graves' ophthalmopathy were examined using high-resolution infrared oculography to determine peak velocities for horizontal eye movements between 3 degrees and 30 degrees. As severity of the orbital disease increased, peak velocities became substantially lower. Vertical-muscle surgery failed to have any effect on peak velocity of horizontal eye movements. In contrast, orbital decompression caused notable improvement in peak velocity of eye movements. Eye-movement recordings, which provide a measure of extraocular muscle function rather than structure, may provide a safe, sensitive, and accurate method for classifying and following up patients with Graves' ophthalmopathy

  4. 59 eyes with endogenous endophthalmitis

    DEFF Research Database (Denmark)

    Bjerrum, Søren Solborg; la Cour, Morten

    2017-01-01

    BACKGROUND: To study the epidemiology of patients with endogenous endophthalmitis in Denmark. MATERIAL AND METHODS: Retrospective and prospective case series of 59 eyes in patients with endogenous endophthalmitis in Denmark between 2000 and 2016. RESULTS: The age of the patients ranged from 28 to......, the visual outcome and the mortality of the patients. The epidemiology of the disease is very different in Scandinavia compared to Asia. The visual prognosis remains grave and the majority of the eyes lose useful vision....

  5. Short-term memory across eye blinks.

    Science.gov (United States)

    Irwin, David E

    2014-01-01

    The effect of eye blinks on short-term memory was examined in two experiments. On each trial, participants viewed an initial display of coloured, oriented lines, then after a retention interval they viewed a test display that was either identical or different by one feature. Participants kept their eyes open throughout the retention interval on some blocks of trials, whereas on others they made a single eye blink. Accuracy was measured as a function of the number of items in the display to determine the capacity of short-term memory on blink and no-blink trials. In separate blocks of trials participants were instructed to remember colour only, orientation only, or both colour and orientation. Eye blinks reduced short-term memory capacity by approximately 0.6-0.8 items for both feature and conjunction stimuli. A third, control, experiment showed that a button press during the retention interval had no effect on short-term memory capacity, indicating that the effect of an eye blink was not due to general motoric dual-task interference. Eye blinks might instead reduce short-term memory capacity by interfering with attention-based rehearsal processes.

  6. Structure and optics of the eyes of the box jellyfish Chiropsella bronzie

    DEFF Research Database (Denmark)

    O’Connor, Megan; Garm, Anders Lydik; Nilsson, Dan-E.

    2009-01-01

    Cubomedusae have a total of 24 eyes of four morphologically different types. Two of these eye types are camera-type eyes (upper and lower lens-eye), while the other two eye types are simpler pigment pit eyes (pit and slit eye). Here, we give a description of the visual system of the box jellyfish...... those in the previously investigated species Tripedalia cystophora. In the lower lens-eye of C. bronzie, blur circles subtend 20 and 52° for closed and open pupil, respectively, effectively removing all but the coarsest structures of the image. Histology reveals that the retina of the lower lens...

  7. Successful treatment of dry eye in two patients with chronic graft-versus-host disease with systemic administration of FK506 and corticosteroids.

    Science.gov (United States)

    Ogawa, Y; Okamoto, S; Kuwana, M; Mori, T; Watanabe, R; Nakajima, T; Yamada, M; Mashima, Y; Tsubota, K; Oguchi, Y

    2001-05-01

    We present two cases of severe dry eye in patients with chronic graft-versus-host disease (CGVHD) after hematopoietic stem cell transplantation (SCT) who were successfully treated by the systemic administration of FK506 and corticosteroids. A 29-year-old man with chronic myelogenous leukemia underwent SCT. Oral and lung CGVHD developed on approximately day 130, and dry eye associated with CGVHD was diagnosed on day 168. The patient began receiving cyclosporin A (150 mg/d) for the treatment of oral and lung CGVHD. Treatment with prednisolone (1 mg/kg/d) began on approximately day 300. Oral and lung GVHD improved slightly, but worsened again although systemic administration of cyclosporin A and prednisolone were continued. Cyclosporin A was discontinued, and systemic administration of FK506 was started on day 376. Forty-four days later, marked improvement in the ocular surface and other organs was observed. However, the dry eye worsened while tapering FK506, with no flare of other affected organs. A 43-year-old woman with myelodysplastic syndrome underwent SCT. She received FK506 for prophylaxis of CGVHD. She had mild dry eye before SCT. Oral and intestinal CGVHD developed, and the dry eye worsened significantly on approximately day 150 while tapering FK506. Treatment with prednisolone (1 mg/kg/d) began, and the dose of FK506 was increased. By day 240, the symptoms of dry eye and the findings of the ocular surface markedly improved, and CGVHD in other organs was completely resolved. However, the improvement in the dry eye was lost when FK506 was tapered for the second time. Systemic administration of FK506 with corticosteroids is an effective treatment of severe dry eye in patients with CGVHD, but long-term administration may be required to achieve a lasting response. These cases also suggest that further investigation into the use of topical FK506 and prednisolone as a maintenance therapy should be pursued.

  8. Does Dry Eye Affect Repeatability of Corneal Topography Measurements?

    Directory of Open Access Journals (Sweden)

    Aysun Şanal Doğan

    2018-04-01

    Full Text Available Objectives: The purpose of this study was to assess the repeatability of corneal topography measurements in dry eye patients and healthy controls. Materials and Methods: Participants underwent consecutive corneal topography measurements (Sirius; Costruzione Strumenti Oftalmici, Florence, Italy. Two images with acquisition quality higher than 90% were accepted. The following parameters were evaluated: minimum and central corneal thickness, aqueous depth, apex curvature, anterior chamber volume, horizontal anterior chamber diameter, iridocorneal angle, cornea volume, and average simulated keratometry. Repeatability was assessed by calculating intra-class correlation coefficient. Results: Thirty-three patients with dry eye syndrome and 40 healthy controls were enrolled to the study. The groups were similar in terms of age (39 [18-65] vs. 30.5 [18-65] years, p=0.198 and gender (M/F: 4/29 vs. 8/32, p=0.366. Intra-class correlation coefficients among all topography parameters within both groups showed excellent repeatability (>0.90. Conclusion: The anterior segment measurements provided by the Sirius corneal topography system were highly repeatable for dry eye patients and are sufficiently reliable for clinical practice and research.

  9. Gaze Estimation Method Using Analysis of Electrooculogram Signals and Kinect Sensor

    Directory of Open Access Journals (Sweden)

    Keiko Sakurai

    2017-01-01

    Full Text Available A gaze estimation system is one of the communication methods for severely disabled people who cannot perform gestures and speech. We previously developed an eye tracking method using a compact and light electrooculogram (EOG signal, but its accuracy is not very high. In the present study, we conducted experiments to investigate the EOG component strongly correlated with the change of eye movements. The experiments in this study are of two types: experiments to see objects only by eye movements and experiments to see objects by face and eye movements. The experimental results show the possibility of an eye tracking method using EOG signals and a Kinect sensor.

  10. Examining the Effects of Chromatic Aberration, Object Distance, and Eye Shape on Image-Formation in the Mirror-Based Eyes of the Bay Scallop Argopecten irradians.

    Science.gov (United States)

    Speiser, Daniel I; Gagnon, Yakir Luc; Chhetri, Raghav K; Oldenburg, Amy L; Johnsen, Sönke

    2016-11-01

    The eyes of scallops form images using a concave spherical mirror and contain two separate retinas, one layered on top of the other. Behavioral and electrophysiological studies indicate that the images formed by these eyes have angular resolutions of about 2°. Based on previous ray-tracing models, it has been thought that the more distal of the two retinas lies near the focal point of the mirror and that the proximal retina, positioned closer to the mirror at the back of the eye, receives light that is out-of-focus. Here, we propose three mechanisms through which both retinas may receive focused light: (1) chromatic aberration produced by the lens may cause the focal points for longer and shorter wavelengths to fall near the distal and proximal retinas, respectively; (2) focused light from near and far objects may fall on the distal and proximal retinas, respectively; and (3) the eyes of scallops may be dynamic structures that change shape to determine which retina receives focused light. To test our hypotheses, we used optical coherence tomography (OCT), a method of near-infrared optical depth-ranging, to acquire virtual cross-sections of live, intact eyes from the bay scallop Argopecten irradians Next, we used a custom-built ray-tracing model to estimate the qualities of the images that fall on an eye's distal and proximal retinas as functions of the wavelengths of light entering the eye (400-700 nm), object distances (0.01-1 m), and the overall shape of the eye. When we assume 550 nm wavelength light and object distances greater than 0.01 m, our model predicts that the angular resolutions of the distal and proximal retinas are 2° and 7°, respectively. Our model also predicts that neither chromatic aberration nor differences in object distance lead to focused light falling on the distal and proximal retinas simultaneously. However, if scallops can manipulate the shapes of their eyes, perhaps through muscle contractions, we speculate that they may be able

  11. [Objective assessment of the functional impact of dry eye severity on the quality of vision by double-pass aberrometry].

    Science.gov (United States)

    Habay, T; Majzoub, S; Perrault, O; Rousseau, C; Pisella, P J

    2014-03-01

    To assess the functional impact of the severity of dry eye on the quality of vision by measuring an Objective Scatter Index (OSI) using double pass aberrometry. Twenty-eight patients (56 eyes) with dry eye syndromes of varying severity participated in this study. A double-pass aberrometer was used to measure the dynamic changes in the OSI for 20 seconds. The mean and standard deviations of the OSI and the number of blinks occurring during the examination were compared as a function of the clinical severity of dry eye disease. The mean OSI increased with the severity of dry eye syndrome with a significant difference for stages 3 (P0.8) or visual acuity (P>0.2). Standard deviation of the OSI also increased with the severity of dry eye disease, with a significant difference for stages 3 (P0.2). The values of the OSI standard deviation represented the dynamic nature of aberrometric changes related to the instability of the tear film. Quality of vision of patients deteriorated in relation to the severity of their dry eye. The analysis of OSI standard deviation appears to be an objective way to assess the intensity of subjective visual disturbances reported by patients with dry eye syndrome. It also provides a new tool to assess the severity of damage to the ocular surface. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  12. About the Eye

    Medline Plus

    Full Text Available ... for Kids >> About the Eye Listen All About Vision About the Eye Ask a Scientist Video Series ... Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun ...

  13. About the Eye

    Medline Plus

    Full Text Available ... eye behind the iris that helps to focus light on the retina. It allows the eye to ... of the eye. It regulates the amount of light entering the eye through the pupil. Pupil (PYOO- ...

  14. Do children with SLI use verbs to predict arguments and adjuncts: evidence from eye movements during listening.

    Directory of Open Access Journals (Sweden)

    Llorenç eAndreu

    2016-01-01

    Full Text Available Different psycholinguistic theories have suggested the importance of verb semantics in rapidly anticipating upcoming information during real-time sentence comprehension. To date, no study has examined if children use verbs to predict arguments and adjuncts in sentence comprehension using children with specific language impairment (SLI.Twenty-five children with SLI (aged 5 years and 3 months to 8 years and 2 months, twenty-five age-matched controls (aged 5 years and 3 months to 8 years and 2 months, twenty-five MLU-w controls (aged 3 years and 3 months to 7 years and 1 month, and 31 adults took part in the study. The eye movements of participants were monitored while they heard twenty-four sentences, such as El hombre lee con atención un cuento en la cama (translation: The man carefully reads a storybook in bed, in the presence of four depicted objects, one of which was the target (storybook, another, the competitor (bed, and another two, distracters (wardrobe and grape. The proportion of looks revealed that, when the meaning of the verb was retrieved, the upcoming argument and adjunct referents were rapidly anticipated. However, the proportion of looks at the theme, source/goal and instrument referents were significantly higher than the looks at the locatives. This pattern was found in adults as well as children with and without language impairment. The present results suggest that, in terms of sentence comprehension, the ability to understand verb information is not severely impaired in children with SLI.

  15. Using Genetic Algorithm for Eye Detection and Tracking in Video Sequence

    Directory of Open Access Journals (Sweden)

    Takuya Akashi

    2007-04-01

    Full Text Available We propose a high-speed size and orientation invariant eye tracking method, which can acquire numerical parameters to represent the size and orientation of the eye. In this paper, we discuss that high tolerance in human head movement and real-time processing that are needed for many applications, such as eye gaze tracking. The generality of the method is also important. We use template matching with genetic algorithm, in order to overcome these problems. A high speed and accuracy tracking scheme using Evolutionary Video Processing for eye detection and tracking is proposed. Usually, a genetic algorithm is unsuitable for a real-time processing, however, we achieved real-time processing. The generality of this proposed method is provided by the artificial iris template used. In our simulations, an eye tracking accuracy is 97.9% and, an average processing time of 28 milliseconds per frame.

  16. Diabetic Eye Disease

    Science.gov (United States)

    ... Disease, & Other Dental Problems Diabetes & Sexual & Urologic Problems Diabetic Eye Disease What is diabetic eye disease? Diabetic eye disease is a group ... eye diseases that can threaten your sight are Diabetic retinopathy The retina is the inner lining at ...

  17. Antioxidant and inflammatory cytokine in tears of patients with dry eye syndrome treated with preservative-free versus preserved eye drops.

    Science.gov (United States)

    Jee, Donghyun; Park, Sang Hee; Kim, Man Soo; Kim, Eun Chul

    2014-07-03

    To compare the antioxidant and inflammatory cytokine activities in tears of patients with dry eye syndrome treated with preservative-free versus preserved eye drops. A total of 100 patients with moderate to severe dry eye syndrome were randomly divided into two groups. Fifty patients (group 1) were treated four times with preservative-free 0.1% sodium hyaluronate and 0.1% fluorometholone eye drops in the first month and with preservative-free 0.1% sodium hyaluronate and 0.05% cyclosporine eye drops in the second and third months. Another 50 patients (group 2) were treated with preserved eye drops on the same schedule. Ocular Surface Disease Index, corneal fluorescein staining, Schirmer I test, tear film breakup time, impression cytology, and antioxidant and inflammatory cytokine activities in tears were evaluated. Treatment with preservative-free eye drops led to significant improvements in symptoms, tear film breakup time, Schirmer I score, and impression cytologic findings compared to treatment with preserved eye drops (P dry eye syndrome. There was a statistically significant decrease in the IL-1β, IL-6, IL-12, and TNF-α concentrations and a statistically significant increase in the catalase, peroxiredoxin 2, superoxide dismutase 2 (SOD 2), and thioredoxin mean fluorescence intensity (MFI) of tears in the preservative-free group at 1, 2, and 3 months compared to initial values, respectively (P eye drops is effective against the dry eye syndrome. Preservative-free eye drops seem to be more effective than preserved eye drops in decreasing ocular inflammation and in increasing antioxidant contents in tears of patients with dry eye syndrome. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  18. Effect of Anterior Chamber Depth on Intraocular Pressure after Uneventful Phacoemulsification Surgery in Nonglaucomatous Eyes with CataractEffect of Anterior Chamber Depth on Intraocular Pressure after Uneventful Phacoemulsification Surgery in Nonglaucomatous Eyes with CataractEffect of Anterior Chamber Depth on Intraocular Pressure after Uneventful Phacoemulsification Surgery in Nonglaucomatous Eyes with Cataract

    Directory of Open Access Journals (Sweden)

    Tansu Gönen

    2011-08-01

    Full Text Available Purpose: To evaluate the effect of preoperative anterior chamber depth (ACD on intraocular pressure (IOP after uneventful phacoemulsification and intraocular lens (IOL implantation in nonglaucomatous eyes. Material and Method: The medical records of fifty-five patients (30 male and 25 female were reviewed retrospectively. The patients who had undergone uneventful phacoemulsification and IOL implantation were divided into two groups according to the values of preoperative ACD: 30 eyes in group 1 (ACD≤3.27 mm and 25 eyes in group 2 (ACD>3.27 mm. IOP was measured using non-contact tonometer preoperatively and postoperatively (1 day, 1 week, 1 month, and 3 months. Results: Three months after phacoemulsification and IOL implantation, the mean IOP decreased 23.6% in group 1 and 13.7% in group 2. There was a statistically significant difference between the groups (p= 0.025. Discussion: The mean IOP decreases in eyes with shallow anterior chamber more than in normal eyes after uncomplicated phacoemulsification and IOL implantation. (Turk J Ophthalmol 2011; 41: 207-12

  19. Optimized Two-Party Video Chat with Restored Eye Contact Using Graphics Hardware

    Science.gov (United States)

    Dumont, Maarten; Rogmans, Sammy; Maesen, Steven; Bekaert, Philippe

    We present a practical system prototype to convincingly restore eye contact between two video chat participants, with a minimal amount of constraints. The proposed six-fold camera setup is easily integrated into the monitor frame, and is used to interpolate an image as if its virtual camera captured the image through a transparent screen. The peer user has a large freedom of movement, resulting in system specifications that enable genuine practical usage. Our software framework thereby harnesses the powerful computational resources inside graphics hardware, and maximizes arithmetic intensity to achieve over real-time performance up to 42 frames per second for 800 ×600 resolution images. Furthermore, an optimal set of fine tuned parameters are presented, that optimizes the end-to-end performance of the application to achieve high subjective visual quality, and still allows for further algorithmic advancement without loosing its real-time capabilities.

  20. Model-based dose calculations for COMS eye plaque brachytherapy using an anatomically realistic eye phantom

    International Nuclear Information System (INIS)

    Lesperance, Marielle; Inglis-Whalen, M.; Thomson, R. M.

    2014-01-01

    Purpose : To investigate the effects of the composition and geometry of ocular media and tissues surrounding the eye on dose distributions for COMS eye plaque brachytherapy with 125 I, 103 Pd, or 131 Cs seeds, and to investigate doses to ocular structures. Methods : An anatomically and compositionally realistic voxelized eye model with a medial tumor is developed based on a literature review. Mass energy absorption and attenuation coefficients for ocular media are calculated. Radiation transport and dose deposition are simulated using the EGSnrc Monte Carlo user-code BrachyDose for a fully loaded COMS eye plaque within a water phantom and our full eye model for the three radionuclides. A TG-43 simulation with the same seed configuration in a water phantom neglecting the plaque and interseed effects is also performed. The impact on dose distributions of varying tumor position, as well as tumor and surrounding tissue media is investigated. Each simulation and radionuclide is compared using isodose contours, dose volume histograms for the lens and tumor, maximum, minimum, and average doses to structures of interest, and doses to voxels of interest within the eye. Results : Mass energy absorption and attenuation coefficients of the ocular media differ from those of water by as much as 12% within the 20–30 keV photon energy range. For all radionuclides studied, average doses to the tumor and lens regions in the full eye model differ from those for the plaque in water by 8%–10% and 13%–14%, respectively; the average doses to the tumor and lens regions differ between the full eye model and the TG-43 simulation by 2%–17% and 29%–34%, respectively. Replacing the surrounding tissues in the eye model with water increases the maximum and average doses to the lens by 2% and 3%, respectively. Substituting the tumor medium in the eye model for water, soft tissue, or an alternate melanoma composition affects tumor dose compared to the default eye model simulation by up

  1. Penetrating eye injuries from writing instruments

    Directory of Open Access Journals (Sweden)

    Kelly SP

    2011-12-01

    Full Text Available Simon P Kelly, Graham MB ReevesThe Royal Bolton Hospital, Bolton, UKPurpose: To consider the potential for ocular injury from writing implements by presenting four such cases, and to consider the incidence of such eye injuries from analysis of a national trauma database.Methods: The Home and Leisure Accident Surveillance System was searched for records of eye injuries from writing instruments to provide UK estimates of such injuries. Four patients with ocular penetrating injury from pens or pencils (especially when caused by children, and examined by the authors, are described which illustrate mechanisms of injury.Results: It is estimated that around 748 ocular pen injuries and 892 ocular pencil injuries of undetermined severity occurred annually in the UK during the database surveillance period 2000–2002. No eye injuries from swords, including toy swords and fencing foils, were reported.Conclusion: Ocular perforation sometimes occur from writing instruments that are thrown in the community, especially by children. Implications for policy and prevention are discussed. Non-specialists should have a low threshold for referring patients with eye injuries if suspicious of ocular penetration, even where caused by everyday objects, such as writing instruments.Keywords: eye injury, eye, children, mechanism, writing instruments, prevention

  2. Angle assessment by EyeCam, goniophotography, and gonioscopy.

    Science.gov (United States)

    Baskaran, Mani; Perera, Shamira A; Nongpiur, Monisha E; Tun, Tin A; Park, Judy; Kumar, Rajesh S; Friedman, David S; Aung, Tin

    2012-09-01

    To compare EyeCam (Clarity Medical Systems, Pleasanton, CA) and goniophotography in detecting angle closure, using gonioscopy as the reference standard. In this hospital-based, prospective, cross-sectional study, participants underwent gonioscopy by a single observer, and EyeCam imaging and goniophotography by different operators. The anterior chamber angle in a quadrant was classified as closed if the posterior trabecular meshwork could not be seen. A masked observer categorized the eyes as per the number of closed quadrants, and an eye was classified as having angle closure if there were 2 or more quadrants of closure. Agreement between the methods was analyzed by κ statistic and comparison of area under receiver operating characteristic curves (AUC). Eighty-five participants (85 eyes) were included, the majority of whom were Chinese. Angle closure was detected in 38 eyes (45%) with gonioscopy, 40 eyes (47%) using EyeCam, and 40 eyes (47%) with goniophotography (P=0.69 in both comparisons, McNemar test). The agreement for angle closure diagnosis (by eye) between gonioscopy and the 2 imaging modalities was high (κ=0.86; 95% Confidence Interval (CI), 0.75-0.97), whereas the agreement between EyeCam and goniophotography was not as good (κ=0.72; 95% CI, 0.57-0.87); largely due to lack of agreement in the nasal and temporal quadrants (κ=0.55 to 0.67). The AUC for detecting eyes with gonioscopic angle closure was similar for goniophotography and EyeCam (AUC 0.93, sensitivity=94.7%, specificity=91.5%; P>0.95). EyeCam and goniophotography have similarly high sensitivity and specificity for the detection of gonioscopic angle closure.

  3. What Is Dry Eye?

    Science.gov (United States)

    ... Eye? Dry Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ... Inside of Your Eyelid Nov 29, 2017 New Dry Eye Treatment is a Tear-Jerker Jul 21, 2017 Three ...

  4. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye Health A-Z Symptoms Glasses & Contacts Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye ... Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ...

  5. The Effect of Tear Supplementation on Ocular Surface Sensations during the Interblink Interval in Patients with Dry Eye.

    Directory of Open Access Journals (Sweden)

    Lóránt Dienes

    Full Text Available To investigate the characteristics of ocular surface sensations and corneal sensitivity during the interblink interval before and after tear supplementation in dry eye patients.Twenty subjects (41.88±14.37 years with dry eye symptoms were included in the dry eye group. Fourteen subjects (39.13±11.27 years without any clinical signs and/or symptoms of dry eye were included in the control group. Tear film dynamics was assessed by non-invasive tear film breakup time (NI-BUT in parallel with continuous recordings of ocular sensations during forced blinking. Corneal sensitivity to selective stimulation of corneal mechano-, cold and chemical receptors was assessed using a gas esthesiometer. All the measurements were made before and 5 min after saline and hydroxypropyl-guar (HP-guar drops.In dry eye patients the intensity of irritation increased rapidly after the last blink during forced blinking, while in controls there was no alteration in the intensity during the first 10 sec followed by an exponential increase. Irritation scores were significantly higher in dry eye patients throughout the entire interblink interval compared to controls (p0.05.Ocular surface irritation responses due to tear film drying are considerably increased in dry eye patients compared to normal subjects. Although tear supplementation improves the protective tear film layer, and thus reduce unpleasant sensory responses, the rapid rise in discomfort is still maintained and might be responsible for the remaining complaints of dry eye patients despite the treatment.

  6. Two-dimensional simulation of broad-band ferrite electromagnetic wave absorbers by using the FDTD method

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Hyun Jin; Kim, Dong Il [Korea Maritime University, Busan (Korea, Republic of)

    2004-10-15

    The purpose of this simulation study is to design and fabricate an electromagnetic (EM) wave absorber in order to develop a wide-band absorber. We have proposed and modeled a bird-eye-type and cutting-cone-type EM wave absorber by using the equivalent material constants method (EMCM), and we simulated them by using a finite-difference time-domain (FDTD) method. A two or a three-dimensional simulation would be desirable to analyze the EM wave absorber characteristics and to develop new structures. The two-dimensional FDTD simulation requires less computer resources than a three-dimensional simulation to consider the structural effects of the EM wave absorbers. The numerical simulation by using the FDTD method shows propagating EM waves in various types of periodic structure EM wave absorbers. Simultaneously, a Fourier analysis is used to characterize the input pulse and the reflected EM waves for ferrite absorbers with various structures. The results have a wide-band reflection-reducing characteristic. The validity of the proposed model was confirmed by comparing the two-dimensional simulation with the experimental results. The simulations were carried out in the frequency band from 30 MHz to 10 GHz.

  7. Two-dimensional simulation of broad-band ferrite electromagnetic wave absorbers by using the FDTD method

    International Nuclear Information System (INIS)

    Yoon, Hyun Jin; Kim, Dong Il

    2004-01-01

    The purpose of this simulation study is to design and fabricate an electromagnetic (EM) wave absorber in order to develop a wide-band absorber. We have proposed and modeled a bird-eye-type and cutting-cone-type EM wave absorber by using the equivalent material constants method (EMCM), and we simulated them by using a finite-difference time-domain (FDTD) method. A two or a three-dimensional simulation would be desirable to analyze the EM wave absorber characteristics and to develop new structures. The two-dimensional FDTD simulation requires less computer resources than a three-dimensional simulation to consider the structural effects of the EM wave absorbers. The numerical simulation by using the FDTD method shows propagating EM waves in various types of periodic structure EM wave absorbers. Simultaneously, a Fourier analysis is used to characterize the input pulse and the reflected EM waves for ferrite absorbers with various structures. The results have a wide-band reflection-reducing characteristic. The validity of the proposed model was confirmed by comparing the two-dimensional simulation with the experimental results. The simulations were carried out in the frequency band from 30 MHz to 10 GHz.

  8. ASSESSMENT OF FUNCTIONAL CHANGES TEAR PRODUCTION UNDER THE ACTION OF THE EYE DROPS ON THE BASE OF NATURAL MOLECULE OF ECTOINE AND ARTIFICIAL TEARS IN PATIENTS WITH DRY EYE SYNDROME ON THE BACKGROUND OF ENDOCRINE OPHTHALMOPATHY.

    Science.gov (United States)

    Veselovskaya, N N; Zherebko, I B

    Conducted a comparative analysis of functional changes in tear production in patients with dry eye syndrome and endocrine ophthalmopathy in the conditions of the long-term acting of preservative free medications based on natural substances. A total of 30 people, aged 35 to 53 years old with clinical manifestations of DES on the background of EO were divided on two groups. In I group eye drops of ectoine and in II - artificial tears were administered. The examination included general and specific methods. The term of follow up - 30 days. It was found that long-term use of preservative free eye drops based on ectoine leads to more expressive positive changes in the condition of the anterior surface of the eye and the secretion and quality of the tear.

  9. Lost to follow-up for appointments in a dedicated dry eye clinic

    Science.gov (United States)

    Poon, Kip Hoe; Yeo, Sharon; Tong, Louis

    2014-01-01

    Objective Dry eye is a prevalent condition with significant socioeconomic burden. This study evaluates the extent and reasons for loss to follow-up (LTF) in a dedicated dry eye clinic. LTF refers to patient who discontinued visits for >2 years. Method The proportion of patients LTF and the demographics in a cohort of dry eye patients (2006 to 2010) were determined. A telephone survey was prospectively conducted for patients who were LTF. Results Of 505 patients, 240 (47.5%) were LTF. Associated demographic factors for LTF were male sex, non-Chinese ethnicity, and age group dry eye condition (47%), personal/social factors (25%) and perceived insufficiency of healthcare delivery (28%). Only two (1.1%) were considered as management failures. The younger patients (age dry eye disease, compared to older patients who were more likely to be LTF due to personal/social reasons (P=0.02). Poor communication and service factors under healthcare delivery were found to be higher (P=0.002) in those who visited once before they were LTF (8.5%) compared to those who visited multiple times before they were LTF (0.1%). Conclusion LTF was relatively common in hospital-based dry eye management. Female and older patients were less likely to stop consultation. Stabilized dry eye condition, common in younger patients, was the most common reason for LTF. Elderly patients have difficulty attending clinics due to nonmedical problems, which may require a more holistic approach. PMID:25336929

  10. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye? Dry Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ... Inside of Your Eyelid Nov 29, 2017 New Dry Eye Treatment is a Tear-Jerker Jul 21, 2017 Three ...

  11. Your Eyes

    Science.gov (United States)

    ... away? If you guessed the eye, you're right! Your eyes are at work from the moment you wake up to the ... the eye is seeing. A Muscle Makes It Work The lens is suspended in ... of the lens. That's right — the lens actually changes shape right inside your ...

  12. Eye shape and the nocturnal bottleneck of mammals.

    Science.gov (United States)

    Hall, Margaret I; Kamilar, Jason M; Kirk, E Christopher

    2012-12-22

    Most vertebrate groups exhibit eye shapes that vary predictably with activity pattern. Nocturnal vertebrates typically have large corneas relative to eye size as an adaptation for increased visual sensitivity. Conversely, diurnal vertebrates generally demonstrate smaller corneas relative to eye size as an adaptation for increased visual acuity. By contrast, several studies have concluded that many mammals exhibit typical nocturnal eye shapes, regardless of activity pattern. However, a recent study has argued that new statistical methods allow eye shape to accurately predict activity patterns of mammals, including cathemeral species (animals that are equally likely to be awake and active at any time of day or night). Here, we conduct a detailed analysis of eye shape and activity pattern in mammals, using a broad comparative sample of 266 species. We find that the eye shapes of cathemeral mammals completely overlap with nocturnal and diurnal species. Additionally, most diurnal and cathemeral mammals have eye shapes that are most similar to those of nocturnal birds and lizards. The only mammalian clade that diverges from this pattern is anthropoids, which have convergently evolved eye shapes similar to those of diurnal birds and lizards. Our results provide additional evidence for a nocturnal 'bottleneck' in the early evolution of crown mammals.

  13. Validation of a chromatographic method for quantitation of 50 μg/mL Latanoprost in a Cuban eye drops

    International Nuclear Information System (INIS)

    Garcia Penna, Caridad Margarita; Martinez Espinosa, Vivian; Gonzalez Cortezon, Ania

    2012-01-01

    Latanoprost is indicated to treat high intraocular pressure in patients suffering from ocular hypertension or from open angle glaucoma. To develop and to validate a high performance liquid chromatography-based analytical method for quality control of 50 μg/mL Latanoprost eye drops

  14. Awareness of eye donation in an adult population of southern India. A pilot study.

    Directory of Open Access Journals (Sweden)

    Priyadarshini Brinda

    2003-01-01

    Full Text Available Purpose: To determine "awareness of eye donation" and corneal transplantation in an adult population of southern India. Methods: 507 participants chosen by systematic random sampling were interviewed using a structured questionnaire. Participants were selected among patients attending two community outreach programmes at different sites, and from patients presenting directly to the hospital. Results: 257 participants (50.69% were aware of eye donations. The major source of awareness was publicity campaigns (n=105. Only 22 (4.34% participants were aware that eye donation had to be done within 6 hours of death. Four hundred and three (79.50% participants were not aware of corneal transplantation. Illiteracy and rural residence were more likely predictors of ignorance. Conclusion: Although multiple strategies are currently followed to increase awareness of eye donations and corneal transplants, more innovative strategies have to be developed, especially to target illiterate and rural populations.

  15. The effects of simulating a realistic eye model on the eye dose of an adult male undergoing head computed tomography.

    Science.gov (United States)

    Akhlaghi, Parisa; Ebrahimi-Khankook, Atiyeh; Vejdani-Noghreiyan, Alireza

    2017-05-01

    In head computed tomography, radiation upon the eye lens (as an organ with high radiosensitivity) may cause lenticular opacity and cataracts. Therefore, quantitative dose assessment due to exposure of the eye lens and surrounding tissue is a matter of concern. For this purpose, an accurate eye model with realistic geometry and shape, in which different eye substructures are considered, is needed. To calculate the absorbed radiation dose of visual organs during head computed tomography scans, in this study, an existing sophisticated eye model was inserted at the related location in the head of the reference adult male phantom recommended by the International Commission on Radiological Protection (ICRP). Then absorbed doses and distributions of energy deposition in different parts of this eye model were calculated and compared with those based on a previous simple eye model. All calculations were done using the Monte Carlo code MCNP4C for tube voltages of 80, 100, 120 and 140 kVp. In spite of the similarity of total dose to the eye lens for both eye models, the dose delivered to the sensitive zone, which plays an important role in the induction of cataracts, was on average 3% higher for the sophisticated model as compared to the simple model. By increasing the tube voltage, differences between the total dose to the eye lens between the two phantoms decrease to 1%. Due to this level of agreement, use of the sophisticated eye model for patient dosimetry is not necessary. However, it still helps for an estimation of doses received by different eye substructures separately.

  16. Fumigation treatment of Four Yellow Qing Ling Water with artificial tears for dry eyes

    Directory of Open Access Journals (Sweden)

    Yan-Yan Chen

    2018-04-01

    Full Text Available AIM: To observe the clinical efficacy of fumigation treatment of traditional Chinese medicine(Four Yellow Qing Ling Waterfor dry eye, and to provide the reference for clinical treatment of dry eye. METHODS: Totally 82 patients(164 eyeswere randomly divided into two groups from June 2016 to December 2016 in Ophthalmology Department of our hospital. The patients in control group were given artificial tears; the patients in the observation group were given artificial tears and fumigation treatment of traditional Chinese(Four Yellow Qing Ling Wateronce a day. After treatment for 14d, the Schirmer Ⅰ test(SⅠt, break-up time(BUT, cornea fluorescein staining(FLand clinical efficacy of two groups were compared. RESULTS: The efficiency rate of observation group was significantly better than the control group(87.8% vs 70.7%, Pvs 6.38±2.52mm/5min, Pvs 6.35±2.29s, Pvs 1.26±0.84, PCONCLUSION: The fumigation treatment of traditional Chinese medicine(Four Yellow Qing Ling Watercombined with artificial tears for dry eyes can improve the clinical symptoms of dry eye syndrome.

  17. Comparative Study of Anterior Eye Segment Measurements with Spectral Swept-Source and Time-Domain Optical Coherence Tomography in Eyes with Corneal Dystrophies.

    Science.gov (United States)

    Nowinska, Anna K; Teper, Sławomir J; Janiszewska, Dominika A; Lyssek-Boron, Anita; Dobrowolski, Dariusz; Koprowski, Robert; Wylegala, Edward

    2015-01-01

    To compare anterior eye segment measurements and morphology obtained with two optical coherence tomography systems (TD OCT, SS OCT) in eyes with corneal dystrophies (CDs). Fifty healthy volunteers (50 eyes) and 54 patients (96 eyes) diagnosed with CD (epithelial basement membrane dystrophy, EBMD = 12 eyes; Thiel-Behnke CD = 6 eyes; lattice CD TGFBI type = 15 eyes; granular CD type 1 = 7 eyes, granular CD type 2 = 2 eyes; macular CD = 23 eyes; and Fuchs endothelial CD = 31 eyes) were recruited for the study. Automated and manual central corneal thickness (aCCT, mCCT), anterior chamber depth (ACD), and nasal and temporal trabecular iris angle (nTIA, tTIA) were measured and compared with Bland-Altman plots. Good agreement between the TD and SS OCT measurements was demonstrated for mCCT and aCCT in normal individuals and for mCCT in the CDs group. The ACD, nTIA, and tTIA measurements differed significantly in both groups. TBCD, LCD, and FECD caused increased CCT. MCD caused significant corneal thinning. FECD affected all analyzed parameters. Better agreement between SS OCT and TD OCT measurements was demonstrated in normal individuals compared to the CDs group. OCT provides comprehensive corneal deposits analysis and demonstrates the association of CD with CCT, ACD, and TIA measurements.

  18. Measuring miniature eye movements by means of a SQUID magnetometer

    NARCIS (Netherlands)

    Peters, M.J.; Dunajski, Z.; Meijzssen, T.E.M.; Breukink, E.W.; Wevers-Henke, J.J.

    1982-01-01

    A new technique to measure small eye movements is reported. The precise recording of human eye movements is necessary for research on visual fatigue induced by visual display units.1 So far all methods used have disadvantages: especially those which are sensitive or are rather painful.2,3 Our method

  19. Deformable Models for Eye Tracking

    DEFF Research Database (Denmark)

    Vester-Christensen, Martin; Leimberg, Denis; Ersbøll, Bjarne Kjær

    2005-01-01

    A deformable template method for eye tracking on full face images is presented. The strengths of the method are that it is fast and retains accuracy independently of the resolution. We compare the me\\$\\backslash\\$-thod with a state of the art active contour approach, showing that the heuristic...

  20. Clinical observation of vitamin B12 eye drops for vision fatigue caused by visual display terminals

    Directory of Open Access Journals (Sweden)

    Qiang Guo

    2016-07-01

    Full Text Available AIM: To investigate the clinical effect of vitamin B12 eye drops for vision fatigue caused by visual display terminals(VDT. METHODS: Totally 50 patients(100 eyeswith vision fatigue caused by VDT were averagely divided into two groups. The control group were treated with normal saline,the treatment group were treated with vitamin B12 eye drops,3 times per day, one drop each time, continuous for 60d. Accommodative parameters and Schirmer Ⅰtest were measured and analyzed before and after treatment. RESULTS:After treatment, the results of Schirmer Ⅰtest, accommodative amplitude and accommodative facility of the treatment group were higher than those of the control group(all PPCONCLUSION: Vitamin B12 eye drops can lessen symptoms of dry eye, improve accommodative function and treat vision fatigue caused by VDT.

  1. Prophylactic treatment to the fellow eye of patients with phakic lattice retinal detachment: analysis of failures and risks of treatment.

    Science.gov (United States)

    Folk, J C; Bennett, S R; Klugman, M R; Arrindell, E L; Boldt, H C

    1990-01-01

    The authors performed a retrospective analysis on 296 phakic patients who had bilateral lattice degeneration and a retinal detachment in one eye. The analysis was done to determine the complications of full prophylactic treatment to lattice and breaks in the fellow eye and to explain the reasons that this treatment sometimes did not prevent new retinal breaks or detachments. The patients were followed for a mean +/- SD of 7.415 +/- 5.422 years after their first detachment. Twenty-four new tears occurred in the fellow eyes during this time, seven (29.2%) of which were away from areas of visible lattice. Prophylactic treatment did not appear to cause new tears or increase the risk of detachment if a new tear occurred. It also did not compromise the surgical repair in those patients who had eyes in which new breaks or detachments developed. The risk of visual loss was similar in those patients receiving prophylactic treatment compared with those not receiving treatment.

  2. CON4EI: EpiOcular™ Eye Irritation Test (EpiOcular™ EIT) for hazard identification and labelling of eye irritating chemicals.

    Science.gov (United States)

    Kandarova, H; Letasiova, S; Adriaens, E; Guest, R; Willoughby, J A; Drzewiecka, A; Gruszka, K; Alépée, Nathalie; Verstraelen, Sandra; Van Rompay, An R

    2018-06-01

    Assessment of the acute eye irritation potential is part of the international regulatory requirements for testing of chemicals. The objective of the CON4EI project was to develop tiered testing strategies for eye irritation assessment. A set of 80 reference chemicals (38 liquids and 42 solids) was tested with eight different methods. Here, the results obtained with the EpiOcular™ Eye Irritation Test (EIT), adopted as OECD TG 492, are shown. The primary aim of this study was to evaluate of the performance of the test method to discriminate between chemicals not requiring classification for serious eye damage/eye irritancy (No Category) and chemicals requiring classification and labelling. In addition, the predictive capacity in terms of in vivo drivers of classification (i.e. corneal opacity, conjunctival redness and persistence at day 21) was investigated. EpiOcular™ EIT achieved a sensitivity of 97%, a specificity of 87% and accuracy of 95% and also confirmed its excellent reproducibility (100%) from the original validation. The assay was applicable to all chemical categories tested in this project and its performance was not limited to the particular driver of the classification. In addition to the existing prediction model for dichotomous categorization, a new prediction model for Cat 1 is suggested. Copyright © 2017. Published by Elsevier Ltd.

  3. [Transpalpebral tonometry with a digital tonometer in healthy eyes and after penetrating keratoplasty].

    Science.gov (United States)

    Amm, M; Hedderich, J

    2005-01-01

    The Goldmann applanation technique established itself as gold standard for clinical intraocular pressure (IOP) measurement. But the device measures by corneal touch and presupposes corneal conditions within a normal range. So precise determination of IOP is crucial in corneal disorders and after corneal surgery. This pilot study presents tonometry data of normal and postkeratoplasty eyes measured transpalpebrally with a digital tonometer in comparison to Goldmann tonometry. The TGDc-01 tonometer is based on a ballistic principle of measurement. IOP was measured in 50 healthy eyes (group 1) and 40 eyes after penetrating keratoplasty (group 2) first by the TGDc-01 and after 3 minutes by Goldmann tonometry (Haag-Streit). Subjective refraction, keratometry and ultrasonic pachymetry were performed in all eyes. The IOP measurements in the postkeratoplasty eyes were done when corneal epithelium was fully closed and only a medium suture edema could be observed. The Pearson's product-moment correlation was r=0,46 for group 1 and 0,65 for group 2. Using the concordance correlation coefficient the value showed a reproducibility index of r(c)=0,44 in group 1 and r(c)=0,60 in group 2. Following the Bland-Altman-analysis 58% of the cases in group 1 had a difference between the two instruments of maximum 3 mmHg. In group 2, 53,5% of the eyes showed an absolute difference between Goldmann and TDGc-01 of 3 mmHg or less. A transpalpebral measurement technique-avoiding corneal contact-seems to be an alternative choice in patients with corneal pathologies and after corneal surgery. The TGDc-01 tonometer provided mostly similar results compared to the Goldmann device, but with fluctuations. Keeping the deviations between the two methods in mind we recommend, however, the use of the transpalpebral approach only in combination with other techniques (palpation, indentation) to obtain enough reliability of IOP information in problem eyes.

  4. Fetal Eye Movements on Magnetic Resonance Imaging

    Science.gov (United States)

    Woitek, Ramona; Kasprian, Gregor; Lindner, Christian; Stuhr, Fritz; Weber, Michael; Schöpf, Veronika; Brugger, Peter C.; Asenbaum, Ulrika; Furtner, Julia; Bettelheim, Dieter; Seidl, Rainer; Prayer, Daniela

    2013-01-01

    Objectives Eye movements are the physical expression of upper fetal brainstem function. Our aim was to identify and differentiate specific types of fetal eye movement patterns using dynamic MRI sequences. Their occurrence as well as the presence of conjugated eyeball motion and consistently parallel eyeball position was systematically analyzed. Methods Dynamic SSFP sequences were acquired in 72 singleton fetuses (17–40 GW, three age groups [17–23 GW, 24–32 GW, 33–40 GW]). Fetal eye movements were evaluated according to a modified classification originally published by Birnholz (1981): Type 0: no eye movements; Type I: single transient deviations; Type Ia: fast deviation, slower reposition; Type Ib: fast deviation, fast reposition; Type II: single prolonged eye movements; Type III: complex sequences; and Type IV: nystagmoid. Results In 95.8% of fetuses, the evaluation of eye movements was possible using MRI, with a mean acquisition time of 70 seconds. Due to head motion, 4.2% of the fetuses and 20.1% of all dynamic SSFP sequences were excluded. Eye movements were observed in 45 fetuses (65.2%). Significant differences between the age groups were found for Type I (p = 0.03), Type Ia (p = 0.031), and Type IV eye movements (p = 0.033). Consistently parallel bulbs were found in 27.3–45%. Conclusions In human fetuses, different eye movement patterns can be identified and described by MRI in utero. In addition to the originally classified eye movement patterns, a novel subtype has been observed, which apparently characterizes an important step in fetal brainstem development. We evaluated, for the first time, eyeball position in fetuses. Ultimately, the assessment of fetal eye movements by MRI yields the potential to identify early signs of brainstem dysfunction, as encountered in brain malformations such as Chiari II or molar tooth malformations. PMID:24194885

  5. In vivo longitudinal chromatic aberration of pseudophakic eyes.

    Science.gov (United States)

    Siedlecki, Damian; Jóźwik, Agnieszka; Zając, Marek; Hill-Bator, Aneta; Turno-Kręcicka, Anna

    2014-02-01

    To present the results of longitudinal chromatic aberration measurements on two groups of pseudophakic eyes in comparison to healthy eyes. The longitudinal chromatic aberration of the eye, defined as chromatic difference of refraction with disabled accommodation, was measured with the use of a visual refractometer with a custom-designed target illuminator consisting of a narrow-band RGB diode (blue λb = 470 ± 15 nm; green λg = 525 ± 18 nm; red λr = 660 ± 10 nm). The measurements were performed on nine eyes implanted with AcrySof IQ SN60WF, 14 eyes implanted with AcrySof SA60AT, and 10 phakic eyes under cycloplegia. The mean values of the longitudinal chromatic aberration between 470 and 660 nm for the control group was 1.12 ± 0.14 D. For SA60AT group, it was 1.45 ± 0.42 D whereas for SN60WF it was 1.17 ± 0.52 D. The statistical test showed significant difference between SA60AT and the control group (p chromatic aberration in vivo can be easily and reliably estimated with an adapted visual refractometer. The two groups of pseudophakic eyes measured in this study showed different values of chromatic aberration. Its magnitude for SA60AT group was significantly larger than for the control group whereas for SN60WF the difference was not significant. The optical material used for intraocular lens design may have significant influence on the magnitude of the chromatic aberration of the pseudophakic eye, and therefore on its optical and visual performance in polychromatic light.

  6. Perceptions of eye health in schools in Pakistan

    Directory of Open Access Journals (Sweden)

    Qureshi Mohammad

    2006-03-01

    Full Text Available Abstract Background Research exploring children's and their teachers' perceptions of eye health is lacking. This paper reports for the first time on perceptions of primary schoolchildren and their teachers of healthy and diseased eyes, things that keep eyes healthy and damage them, and what actions to be taken in case of an eye injury. Methods Using draw and write technique, 160 boys and girls (9–12 years old attending four primary schools in Abbottabad district, northern Pakistan, were invited to draw pictures in response to a set of semi-structured questions and then label them. Sixteen teachers who were currently teaching the selected students were interviewed one-on-one. Results Analysis of text accompanying 800 drawings and of the interview scripts revealed that most children and teachers perceived healthy eyes to be those which could see well, and diseased eyes to be those which have redness, watering, dirty discharge, pain, and itching; or those which have "weak eyesight" and blindness. Among things that students and teachers thought damage the eyes included sun, television, and sharp pointed objects, particularly pencils. Teachers noted that children with eye problems "have difficulty seeing the blackboard well", "screw up their eyes", and "hold their books too close". Conclusion We conclude that schoolchildren and their teachers had a good knowledge of eye health, but many of them had serious misconceptions e.g., use of kohl, medicines and eye drops keeps eyes healthy. Kohl is an important source of lead and can reduce children's intelligence even at low blood levels. Health education in schools must take into account children's existing knowledge of and misconceptions about various aspects of eye health. Such steps if taken could improve the relevance of eye health education to schoolchildren.

  7. Optical, gravitational, and kinesthetic determinants of judged eye level

    Science.gov (United States)

    Stoper, Arnold E.; Cohen, Malcolm M.

    1989-01-01

    Subjects judged eye level, defined in three distinct ways relative to three distinct reference planes: a gravitational horizontal, giving the gravitationally referenced eye level (GREL); a visible surface, giving the surface-referenced eye level (SREL); and a plane fixed with respect to the head, giving the head-referenced eye level (HREL). The information available for these judgements was varied by having the subjects view an illuminated target that could be placed in a box which: (1) was pitched at various angles, (2) was illuminated or kept in darkness, (3) was moved to different positions along the subject's head-to-foot body axis, and (4) was viewed with the subjects upright or reclining. The results showed: (1) judgements of GREL made in the dark were 2.5 deg lower than in the light, with a significantly greater variability; (2) judged GREL was shifted approximately half of the way toward SREL when these two eye levels did not coincide; (3) judged SREL was shifted about 12 percent of the way toward HREL when these two eye levels did not coincide, (4) judged HREL was shifted about half way toward SREL when these two eye level did not coincide and when the subject was upright (when the subject was reclining, HREL was shifted approx. 90 percent toward SREL); (5) the variability of the judged HREL in the dark was nearly twice as great with the subject reclining than with the subject upright. These results indicate that gravity is an important source of information for judgement of eye level. In the absence of information concerning the direction of gravity, the ability to judge HREL is extremely poor. A visible environment does not seem to afford precise information as to judgements of direction, but it probably does afford significant information as to the stability of these judgements.

  8. Unilateral Keratoconus after Chronic Eye Rubbing by the Nondominant Hand

    Directory of Open Access Journals (Sweden)

    Nathalie Bral

    2017-12-01

    Full Text Available Introduction: To report the development of unilateral keratoconus in a healthy male after persistent unilateral eye rubbing by the nondominant hand which was not needed for professional activities. Methods: Observational case report. Results: A 60-year-old male was first seen in our clinic due to decreased vision in his left eye. Slit-lamp biomicroscopy of the left eye revealed Vogt’s striae, stromal thinning, and a stromal scar. Corneal topography showed a stage 4 keratoconus. Clinical examination and corneal topography of the right eye were normal. Medical history revealed a habit of chronic eye rubbing only in the left eye because of the right hand being occupied for professional needs. During follow-up of 5 years, Scheimpflug images of the right eye stayed normal while the left eye showed a stable cone. Discussion: This case report supports the hypothesis of mechanical fatigue of the cornea due to repetitive shear stress on the surface caused by eye-rubbing.

  9. Phantom pain after eye amputation

    DEFF Research Database (Denmark)

    Rasmussen, Marie L R; Prause, Jan U; Toft, Peter B

    2011-01-01

    Purpose: To characterize the quality of phantom pain, its intensity and frequency following eye amputation. Possible triggers and relievers of phantom pain are investigated. Methods: The hospital database was searched using surgery codes for patients who received ocular evisceration, enucleation...... was conducted by a trained interviewer. Results: Of the 173 patients in the study, 39 experienced phantom pain. The median age of patients who had experienced phantom pain was 45 years (range: 19–88). Follow-up time from eye amputation to participation in the investigation was 4 years (range: 2–46). Phantom...... scale, ranging from 0 to 100, was 36 (range: 1–89). One-third of the patients experienced phantom pain every day. Chilliness, windy weather and psychological stress/fatigue were the most commonly reported triggers for pain. Conclusions: Phantom pain after eye amputation is relatively common. The pain...

  10. Comparison of the efficacy of topical cyclosporine with fluromethalone in treatment of dry eye disease

    International Nuclear Information System (INIS)

    Erum, N.; Rasul, A.; Yaqub, A.; Malik, A. M.

    2017-01-01

    Objective: To compare the efficacy of 0.05 percent cyclosporine eye drops with 0.1 percentage fluromethalone eye drops on keratoconjunctivitis sicca (dry eye disease). Study Design: Randomized controlled trial. Place and Duration of Study: Ophthalmology department of HIT Hospital Taxila, from Oct 2014 to May 2015. Material and Methods: The patients with keratoconjunctivitis sicca (KCS) were selected from outpatient and divided in two treatment groups. The dry eye disease was defined according to criteria set by International task force for dry eye disease (ITF). The group I was treated with 0.05 percent cyclosporine drops while group-II was treated with 0.1 percent fluromethalone eye drops three times a day after informed written consent. The patients were followed up after three months and six months. Results: At the start of treatment 94 patients were placed in two treatment groups (n=47 in each group) and all the patients with KCS were graded according to severity following rules set by ITF. There were 46 patients in grade III (severe) KCS and 20 patients in grade IV (very severe) KCS. At the end of study only 24 were in grade II (moderate) KCS and 2 in grade III KCS. Of these only 5 patients in grade II and none in grade III were in treatment group I (cyclosporine). The remaining 19 patients in grade II and 5 patients in grade III KCS belonged to group II (fluromethalone). Conclusion: Cyclosporine eye drops are better than fluromethalone in treatment of keratoconjunctivitis sicca. (author)

  11. A prospective, comparative, observational study on optical coherence tomography of the anterior eye segment

    NARCIS (Netherlands)

    Theelen, T.; Hoyng, C.B.

    2013-01-01

    BACKGROUND: We compared two commercially available spectral-domain optical coherence tomography (OCT) devices according to their capacity of imaging the anterior segment of the eye with the same detail and quality. METHODS: A prospective, observational, single-visit study with individuals aged 18

  12. Central crosstalk for somatic tinnitus: abnormal vergence eye movements.

    Directory of Open Access Journals (Sweden)

    Qing Yang

    Full Text Available BACKGROUND: Frequent oulomotricity problems with orthoptic testing were reported in patients with tinnitus. This study examines with objective recordings vergence eye movements in patients with somatic tinnitus patients with ability to modify their subjective tinnitus percept by various movements, such as jaw, neck, eye movements or skin pressure. METHODS: Vergence eye movements were recorded with the Eyelink II video system in 15 (23-63 years control adults and 19 (36-62 years subjects with somatic tinnitus. FINDINGS: 1 Accuracy of divergence but not of convergence was lower in subjects with somatic tinnitus than in control subjects. 2 Vergence duration was longer and peak velocity was lower in subjects with somatic tinnitus than in control subjects. 3 The number of embedded saccades and the amplitude of saccades coinciding with the peak velocity of vergence were higher for tinnitus subjects. Yet, saccades did not increase peak velocity of vergence for tinnitus subjects, but they did so for controls. 4 In contrast, there was no significant difference of vergence latency between these two groups. INTERPRETATION: The results suggest dysfunction of vergence areas involving cortical-brainstem-cerebellar circuits. We hypothesize that central auditory dysfunction related to tinnitus percept could trigger mild cerebellar-brainstem dysfunction or that tinnitus and vergence dysfunction could both be manifestations of mild cortical-brainstem-cerebellar syndrome reflecting abnormal cross-modality interactions between vergence eye movements and auditory signals.

  13. Analysis and implementation of the foveated vision of the raptor eye

    Science.gov (United States)

    Long, Aaron D.; Narayanan, Ram M.; Kane, Timothy J.; Rice, Terence F.; Tauber, Michael J.

    2016-05-01

    A foveated optical system has non-uniform resolution across its field of view. Typically, the resolution of such a lens is peaked in the center region of field of view, such as in the human eye. In biological systems this is often a result of localized depressions on the retina called foveae. Birds of prey, or raptors, have two foveae in each eye, each of which accounts for a localized region of high magnification within the raptor's field of view. This paper presents an analysis of the bifoveated vision of raptors and presents a method whereby this unique optical characteristic may be achieved in an optical system using freeform optics and aberration correction techniques.

  14. The Effect of Immunologically Safe Plasma Rich in Growth Factor Eye Drops in Patients with Sjögren Syndrome.

    Science.gov (United States)

    Sanchez-Avila, Ronald Mauricio; Merayo-Lloves, Jesus; Riestra, Ana Cristina; Anitua, Eduardo; Muruzabal, Francisco; Orive, Gorka; Fernández-Vega, Luis

    2017-06-01

    The objective was to provide preliminary information about the efficacy and safety of immunologically safe plasma rich in growth factor (immunosafe PRGF) eye drops in the treatment of moderate to severe dry eye in patients with primary and secondary Sjögren's syndrome (SS) and to analyze the influence of several variables on treatment outcomes. This retrospective study included patients with SS. All patients were treated with previously immunosafe PRGF eye drops to reduce the immunologic component contents. Ocular Surface Disease Index (OSDI) scale, best-corrected visual acuity (BCVA), visual analog scale (VAS) frequency, and VAS severity outcome measures were evaluated before and after treatment with immunosafe PRGF. The potential influence of some patient clinical variables on results was also assessed. Safety assessment was also performed reporting all adverse events. Twenty-six patients (12 patients with primary SS, and 14 patients suffering secondary SS) with a total of 52 affected eyes were included and evaluated. Immunosafe PRGF treatment showed a significant reduction (P PRGF with corticosteroids. Only 2 adverse events were reported in 2 patients (7.7% of patients). Signs and symptoms of dry eye syndrome in patients with SS were reduced after treatment with PRGF-Endoret eye drops. Immunosafe PRGF-Endoret is safe and effective for treating patients with primary and secondary SS.

  15. Cosmetics Europe compilation of historical serious eye damage/eye irritation in vivo data analysed by drivers of classification to support the selection of chemicals for development and evaluation of alternative methods/strategies: the Draize eye test Reference Database (DRD).

    Science.gov (United States)

    Barroso, João; Pfannenbecker, Uwe; Adriaens, Els; Alépée, Nathalie; Cluzel, Magalie; De Smedt, Ann; Hibatallah, Jalila; Klaric, Martina; Mewes, Karsten R; Millet, Marion; Templier, Marie; McNamee, Pauline

    2017-02-01

    A thorough understanding of which of the effects assessed in the in vivo Draize eye test are responsible for driving UN GHS/EU CLP classification is critical for an adequate selection of chemicals to be used in the development and/or evaluation of alternative methods/strategies and for properly assessing their predictive capacity and limitations. For this reason, Cosmetics Europe has compiled a database of Draize data (Draize eye test Reference Database, DRD) from external lists that were created to support past validation activities. This database contains 681 independent in vivo studies on 634 individual chemicals representing a wide range of chemical classes. A description of all the ocular effects observed in vivo, i.e. degree of severity and persistence of corneal opacity (CO), iritis, and/or conjunctiva effects, was added for each individual study in the database, and the studies were categorised according to their UN GHS/EU CLP classification and the main effect driving the classification. An evaluation of the various in vivo drivers of classification compiled in the database was performed to establish which of these are most important from a regulatory point of view. These analyses established that the most important drivers for Cat 1 Classification are (1) CO mean ≥ 3 (days 1-3) (severity) and (2) CO persistence on day 21 in the absence of severity, and those for Cat 2 classification are (3) CO mean ≥ 1 and (4) conjunctival redness mean ≥ 2. Moreover, it is shown that all classifiable effects (including persistence and CO = 4) should be present in ≥60 % of the animals to drive a classification. As a consequence, our analyses suggest the need for a critical revision of the UN GHS/EU CLP decision criteria for the Cat 1 classification of chemicals. Finally, a number of key criteria are identified that should be taken into consideration when selecting reference chemicals for the development, evaluation and/or validation of alternative methods and

  16. A two-step patterning process increases the robustness of periodic patterning in the fly eye.

    Science.gov (United States)

    Gavish, Avishai; Barkai, Naama

    2016-06-01

    Complex periodic patterns can self-organize through dynamic interactions between diffusible activators and inhibitors. In the biological context, self-organized patterning is challenged by spatial heterogeneities ('noise') inherent to biological systems. How spatial variability impacts the periodic patterning mechanism and how it can be buffered to ensure precise patterning is not well understood. We examine the effect of spatial heterogeneity on the periodic patterning of the fruit fly eye, an organ composed of ∼800 miniature eye units (ommatidia) whose periodic arrangement along a hexagonal lattice self-organizes during early stages of fly development. The patterning follows a two-step process, with an initial formation of evenly spaced clusters of ∼10 cells followed by a subsequent refinement of each cluster into a single selected cell. Using a probabilistic approach, we calculate the rate of patterning errors resulting from spatial heterogeneities in cell size, position and biosynthetic capacity. Notably, error rates were largely independent of the desired cluster size but followed the distributions of signaling speeds. Pre-formation of large clusters therefore greatly increases the reproducibility of the overall periodic arrangement, suggesting that the two-stage patterning process functions to guard the pattern against errors caused by spatial heterogeneities. Our results emphasize the constraints imposed on self-organized patterning mechanisms by the need to buffer stochastic effects. Author summary Complex periodic patterns are common in nature and are observed in physical, chemical and biological systems. Understanding how these patterns are generated in a precise manner is a key challenge. Biological patterns are especially intriguing, as they are generated in a noisy environment; cell position and cell size, for example, are subject to stochastic variations, as are the strengths of the chemical signals mediating cell-to-cell communication. The need

  17. The role of eye protection in work-related eye injuries.

    Science.gov (United States)

    Fong, L P; Taouk, Y

    1995-05-01

    A recent survey of general hospitals by the Victorian Injury Surveillance System found that ocular trauma represented 15% of work-related injuries. As circumstances surrounding occupational eye injuries have been poorly documented previously, their associations to occupation, industry and work-safety practices, including safety eyewear use, need to be identified to develop appropriate preventive strategies for high-risk groups. From a prospective cross-sectional survey of all eye injuries treated at the Royal Victorian Eye and Ear Hospital, work-related cases were analysed for demographic, occupational and safety eye-wear information. Hospital-based data were supplemented by information from WorkCover Authorities and Labour Force statistics to derive incidence and cost estimates. There were 9390 eye injuries during the 18-month survey period; 42% (n=3923) of total and 29% (n=52) of penetrating ocular injuries occurred at work. The most frequently injured were metal, automotive and building trades workers grinding and drilling (41% of outpatients) and hammering (53% of penetrating eye injuries). Automotive workers had the highest frequency for penetrating injuries, and most were exposed to hammering and were also the least likely to wear safety eye-wear. Eye injuries are frequent (10% of work-related injuries) and highly preventable by the correct use of safety eye-wear, a cost-effective intervention that may result in cost savings of $59 million for work-type activities in the occupational and domestic settings in Australia each year.

  18. Risk factors for prelacteal feeding in sub-Saharan Africa: a multilevel analysis of population data from twenty-two countries.

    Science.gov (United States)

    Berde, Anselm S; Ozcebe, Hilal

    2017-08-01

    To examine the risk factors of prelacteal feeding (PLF) among mothers in sub-Saharan Africa (SSA). We pooled data from Demographic and Health Surveys in twenty-two SSA countries. The key outcome variable was PLF. A multilevel logistic regression model was used to explore factors associated with PLF. Demographic and Health Surveys in twenty-two SSA countries. Mother-baby pairs (n 95348). Prevalence of PLF in SSA was 32·2 %. Plain water (22·1 %), milk other than breast milk (5·0 %) and sugar or glucose water (4·1 %) were the predominant prelacteal feeds. In the multivariable analysis, mothers who had caesarean section delivery had 2·25 times the odds of giving prelacteal feeds compared with mothers who had spontaneous vaginal delivery (adjusted OR=2·25; 95 % CI 2·06, 2·46). Other factors that were significantly associated with increased likelihood of PLF were mother's lower educational status, first birth rank, fourth or above birth rank with preceding birth interval less than or equal to 24 months, lower number of antenatal care visits, home delivery, multiple birth, male infant, as well as having an average or small sized baby at birth. Mothers aged 20-34 years were less likely to give prelacteal feeds compared with mothers aged ≤19 years. Belonging to the second, middle or fourth wealth quintile was associated with lower likelihood of PLF compared with the highest quintile. To achieve optimal breast-feeding, there is a need to discourage breast-feeding practices such as PLF. Breast-feeding promotion programmes should target the at-risk sub-population groups discovered in our study.

  19. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ... Your Eyelid Nov 29, 2017 New Dry Eye Treatment is a Tear-Jerker Jul 21, 2017 Three ...

  20. Analysis of Ocular Firework-Related Injuries and Common Eye Traumata: a 5-year Clinical Study.

    Science.gov (United States)

    Frimmel, S; Theusinger, O M; Kniestedt, C

    2017-04-01

    Background A comparative study of eye injuries related to fireworks or acts of violence around New Year's Eve and the Swiss National Day on August 1st. The two groups were compared with respect to the overall numbers of eye accidents within the period of review. Patients and Methods Retrospective analysis of emergency consultations at the Department of Ophthalmology, University Hospital Zurich with eye accidents around the Swiss National Day on August 1st and New Year's Eve over the last 5 years. Two subgroups were formed: (1) Firework-related eye traumata, (2) Eye injuries due to acts of violence. The groups were analysed by age, gender, active participant or bystander, eye involved, severity of trauma (from clinical findings), surgical interventions, time of follow-up and visits, visual acuity and outcome. Results The study included 97 patients (100 eyes) with 74 male (76 %) and 23 female (24 %) victims. After filtering out 67 common traumata cases (all unilateral), 17 patients (18 eyes) with firework-related injuries and 13 patients (15 eyes) with damage due to an act of violence remained. Firework injuries accounted for 18 % of cases (65 % men); eye injuries caused by an act of violence accounted for 15 % of cases (92 % men). In the fireworks group, women were significantly older than men (mean age men 32 ± 14 years versus women 38 ± 16 years, p = 0.002). 65 % of cases were bystanders. The two subgroups contained 30 patients (33 eyes) with 22 left eyes (67 %, p fireworks group (28 %), than in the violence group (13 %). 87 % of the victims in the group of common traumata were mild trauma, 10 % moderate and 3 % severe. In the fireworks group the distribution was 53 % mild, 12 % moderate and 35 % severe, in the violence group 46 %, 23 % and 31 % respectively. Severe trauma cases occurred significantly more often around the New Year, with 36 % versus August 1st with 18 % (p = 0.0028). They are more often

  1. Effects of sodium hyaluronate on ocular inflammatory response and dry eye after phacoemulsification combined with IOL implantation for cataract

    Directory of Open Access Journals (Sweden)

    Xing-Guang He

    2018-04-01

    Full Text Available AIM: To investigate the effect of sodium hyaluronate eye drops on ocular inflammatory response and dry eye after phacoemulsification combined with intraocular lenses(IOLimplantation for age-related cataract. METHODS: The clinical data of age-related cataract patients treated with phacoemulsification combined with IOL implantation in 200 cases(200 eyesof our hospital from June 2016 to July 2017 were retrospectively analyzed. According to the different postoperative application of eye drops they were divided into observation group and control group(100 cases each. The observation group was given sodium hyaluronate eye drops and the control group was given tobramycin dexamethasone eye drops. The results of BUT, FL, proteins concentration in aqueous and ocular surface disease index(OSDIscore were compared before and at the first day, the seventh day and the fourteenth day after the operation. And the incidence of conjunctival hyperemia and ciliary hyperemia was compared between 1d after surgery and 14d after surgery. RESULTS: There was no significant difference in OSDI scores between the two groups before and at 1d after surgery(P>0.05. The OSDI score of the two groups was higher than that before the operation on the first, the seventh and the fourteenth day after surgery(PPPP>0.05. The levels of BUT in the two groups were lower than those before operation on the first, the seventh and the fourteenth day after surgery(PPPP>0.05. The levels of FL in the two groups were different from those before operation(PPPPP>0.05; the incidence of conjunctival hyperemia and ciliary hyperemia in the two groups on the fourteenth day after surgery was lower than that on the first day after surgery(PPPPPCONCLUSION: The effect of sodium hyaluronate eye drops on improving dry eye after age-related cataract phacoemulsification combined with IOL implantation is greater than that of tobramycin dexamethasone eye drops, but it is less effective for eye inflammation than

  2. Photorefraction of eyes: history and future prospects.

    Science.gov (United States)

    Howland, Howard C

    2009-06-01

    A brief history of photorefraction, i.e., the refraction of eyes by photography or computer image capture, is given. The method of photorefraction originated from an optical scheme for secret communication across the Berlin wall. This scheme used a lens whose focus about infinity was modulated by a movable reflecting surface. From this device, it was recognized that the vertebrate eye was such a reflector and that its double-pass pointspread could be used to compute its degree of defocus. Subsequently, a second, totally independent invention, more accurately termed "photoretinoscopy," used an eccentric light source and obtained retinoscopic-like images of the reflex in the pupil of the subject's eyes. Photoretinoscopy has become the preferred method of photorefraction and has been instantiated in a wide variety of devices used in vision screening and research. This has been greatly helped by the parallel development of computer and digital camera technology. It seems likely that photorefractive methods will continue to be refined and may eventually become ubiquitous in clinical practice.

  3. Access to eye health services among indigenous Australians: an area level analysis

    Directory of Open Access Journals (Sweden)

    Kelaher Margaret

    2012-09-01

    Full Text Available Abstract Background This project is a community-level study of equity of access to eye health services for Indigenous Australians. Methods The project used data on eye health services from multiple sources including Medicare Australia, inpatient and outpatient data and the National Indigenous Eye Health Survey. The analysis focused on the extent to which access to eye health services varied at an area level according to the proportion of the population that was Indigenous (very low = 0-1.0%, low = 1.1-3.0%, low medium = 3.1-6.0%, high medium = 6.1-10.0%, high = 10.1-20.0%, very high = 20 + %. The analysis of health service utilisation also took into account age, remoteness and the Socioeconomic Indices for Areas (SEIFA. Results The rate of eye exams provided in areas with very high Indigenous populations was two-thirds of the rate of eye exams for areas with very low indigenous populations. The cataract surgery rates in areas with high medium to very high Indigenous populations were less than half that reference areas. In over a third of communities with very high Indigenous populations the cataract surgery rate fell below the World Health Organization (WHO guidelines compared to a cataract surgery rate of 3% in areas with very low Indigenous populations. Conclusions There remain serious disparities in access to eye health service in areas with high Indigenous populations. Addressing disparities requires a co-ordinated approach to improving Indigenous people’s access to eye health services. More extensive take-up of existing Medicare provisions is an important step in this process. Along with improving access to health services, community education concerning the importance of eye health and the effectiveness of treatment might reduce reluctance to seek help.

  4. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye Health / Eye Health A-Z Dry Eye ... Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué es el ojo seco? Written By: Kierstan ...

  5. Dry Eye Management: Targeting the Ocular Surface Microenvironment

    Science.gov (United States)

    Zhang, Xiaobo; Jeyalatha M, Vimalin; Qu, Yangluowa; He, Xin; Ou, Shangkun; Bu, Jinghua; Jia, Changkai; Wang, Junqi; Wu, Han; Liu, Zuguo

    2017-01-01

    Dry eye can damage the ocular surface and result in mild corneal epithelial defect to blinding corneal pannus formation and squamous metaplasia. Significant progress in the treatment of dry eye has been made in the last two decades; progressing from lubricating and hydrating the ocular surface with artificial tear to stimulating tear secretion; anti-inflammation and immune regulation. With the increase in knowledge regarding the pathophysiology of dry eye, we propose in this review the concept of ocular surface microenvironment. Various components of the microenvironment contribute to the homeostasis of ocular surface. Compromise in one or more components can result in homeostasis disruption of ocular surface leading to dry eye disease. Complete evaluation of the microenvironment component changes in dry eye patients will not only lead to appropriate diagnosis, but also guide in timely and effective clinical management. Successful treatment of dry eye should be aimed to restore the homeostasis of the ocular surface microenvironment. PMID:28661456

  6. Dry Eye Management: Targeting the Ocular Surface Microenvironment.

    Science.gov (United States)

    Zhang, Xiaobo; M, Vimalin Jeyalatha; Qu, Yangluowa; He, Xin; Ou, Shangkun; Bu, Jinghua; Jia, Changkai; Wang, Junqi; Wu, Han; Liu, Zuguo; Li, Wei

    2017-06-29

    Dry eye can damage the ocular surface and result in mild corneal epithelial defect to blinding corneal pannus formation and squamous metaplasia. Significant progress in the treatment of dry eye has been made in the last two decades; progressing from lubricating and hydrating the ocular surface with artificial tear to stimulating tear secretion; anti-inflammation and immune regulation. With the increase in knowledge regarding the pathophysiology of dry eye, we propose in this review the concept of ocular surface microenvironment. Various components of the microenvironment contribute to the homeostasis of ocular surface. Compromise in one or more components can result in homeostasis disruption of ocular surface leading to dry eye disease. Complete evaluation of the microenvironment component changes in dry eye patients will not only lead to appropriate diagnosis, but also guide in timely and effective clinical management. Successful treatment of dry eye should be aimed to restore the homeostasis of the ocular surface microenvironment.

  7. Effects of diquafosol sodium eye drops on tear film stability in short BUT type of dry eye.

    Science.gov (United States)

    Shimazaki-Den, Seika; Iseda, Hiroyuki; Dogru, Murat; Shimazaki, Jun

    2013-08-01

    To investigate the effects of diquafosol sodium (DQS) eye drops, a purinergic P2Y2 receptor agonist, on tear film stability in patients with unstable tear film (UTF). Two prospective studies were conducted. One was an exploratory nonrandomized trial on 39 eyes with dry eye symptoms and short tear film break-up time (BUT), but without epithelial damage. Changes in symptoms, BUT, Schirmer value, and ocular surface fluorescein staining (FS) scores were studied for 3 months. The other was a randomized clinical trial of DQS and artificial tears (AT) in 17 eyes with short BUT. Eyes with decreased Schirmer values (≤ 5 mm) were excluded. Changes in symptoms, BUT, FS scores, and tear film stability using continuous corneal topographic analysis were studied for 4 weeks. In the exploratory study, while Schirmer values were not significantly increased, significant improvements in symptoms and BUT were noted at both 1 and 3 months. In the randomized clinical trial, significant improvements in symptoms were noted in the DQS group, but not in the AT group, at 2 weeks. BUT was significantly prolonged in the DQS group at 4 weeks but not in the AT group. No significant changes were noted in FS scores or tear film stability. DQS improved subjective symptoms and prolonged BUT in eyes with UTF not associated with low tear secretion and ocular surface epithelial damage. Because many patients who have UTF are refractory to conventional treatments, DQS may offer benefits in the treatment of dry eyes.

  8. Constructing a Computer Model of the Human Eye Based on Tissue Slice Images

    OpenAIRE

    Dai, Peishan; Wang, Boliang; Bao, Chunbo; Ju, Ying

    2010-01-01

    Computer simulation of the biomechanical and biological heat transfer in ophthalmology greatly relies on having a reliable computer model of the human eye. This paper proposes a novel method on the construction of a geometric model of the human eye based on tissue slice images. Slice images were obtained from an in vitro Chinese human eye through an embryo specimen processing methods. A level set algorithm was used to extract contour points of eye tissues while a principle component analysi...

  9. Ahmed Glaucoma Valve Implantation in Vitrectomized Eyes

    OpenAIRE

    Erçalık, Nimet Yeşim; İmamoğlu, Serhat

    2018-01-01

    Purpose. To evaluate the outcomes of Ahmed glaucoma valve (AGV) implantation in vitrectomized eyes. Materials and Methods. The medical records of 13 eyes that developed glaucoma due to emulsified silicon oil or neovascularization following pars plana vitrectomy and underwent AGV implantation were retrospectively reviewed. The main outcome measures were intraocular pressure (IOP), best-corrected visual acuity (BCVA), number of antiglaucoma medications, and postoperative complications. Surgical...

  10. Higher order aberrations of the eye: Part one

    Directory of Open Access Journals (Sweden)

    Marsha Oberholzer

    2016-06-01

    Full Text Available This article is the first in a series of two articles that provide a comprehensive literature review of higher order aberrations (HOAs of the eye. The present article mainly explains the general principles of such HOAs as well as HOAs of importance, and the measuring apparatus used to measure HOAs of the eye. The second article in the series discusses factors contributing to variable results in measurements of HOAs of the eye. Keywords: Higher order aberrations; wavefront aberrations; aberrometer

  11. Dry eyes : a commonly missed eye condition

    OpenAIRE

    Vella, Mario;

    2014-01-01

    Tears are an important component in providing moisture and lubrication for the eyes, thereby maintaining vision and comfort. Dry eyes (keratoconjunctivitis sicca) result when there is either decreased production of tears or by poor tear quality which in turn lead to more rapid evaporation.

  12. Optical Coherence Tomography Angiography Vessel Density in Healthy, Glaucoma Suspect, and Glaucoma Eyes

    Science.gov (United States)

    Yarmohammadi, Adeleh; Zangwill, Linda M.; Diniz-Filho, Alberto; Suh, Min Hee; Manalastas, Patricia Isabel; Fatehee, Naeem; Yousefi, Siamak; Belghith, Akram; Saunders, Luke J.; Medeiros, Felipe A.; Huang, David; Weinreb, Robert N.

    2016-01-01

    Purpose The purpose of this study was to compare retinal nerve fiber layer (RNFL) thickness and optical coherence tomography angiography (OCT-A) retinal vasculature measurements in healthy, glaucoma suspect, and glaucoma patients. Methods Two hundred sixty-one eyes of 164 healthy, glaucoma suspect, and open-angle glaucoma (OAG) participants from the Diagnostic Innovations in Glaucoma Study with good quality OCT-A images were included. Retinal vasculature information was summarized as a vessel density map and as vessel density (%), which is the proportion of flowing vessel area over the total area evaluated. Two vessel density measurements extracted from the RNFL were analyzed: (1) circumpapillary vessel density (cpVD) measured in a 750-μm-wide elliptical annulus around the disc and (2) whole image vessel density (wiVD) measured over the entire image. Areas under the receiver operating characteristic curves (AUROC) were used to evaluate diagnostic accuracy. Results Age-adjusted mean vessel density was significantly lower in OAG eyes compared with glaucoma suspects and healthy eyes. (cpVD: 55.1 ± 7%, 60.3 ± 5%, and 64.2 ± 3%, respectively; P glaucoma and healthy eyes, the age-adjusted AUROC was highest for wiVD (0.94), followed by RNFL thickness (0.92) and cpVD (0.83). The AUROCs for differentiating between healthy and glaucoma suspect eyes were highest for wiVD (0.70), followed by cpVD (0.65) and RNFL thickness (0.65). Conclusions Optical coherence tomography angiography vessel density had similar diagnostic accuracy to RNFL thickness measurements for differentiating between healthy and glaucoma eyes. These results suggest that OCT-A measurements reflect damage to tissues relevant to the pathophysiology of OAG. PMID:27409505

  13. The current status of eye lens dose measurement in interventional cardiology personnel in Thailand.

    Science.gov (United States)

    Krisanachinda, Anchali; Srimahachota, Suphot; Matsubara, Kosuke

    2017-06-01

    Workers involved in interventional cardiology procedures receive high eye lens doses if radiation protection tools are not properly utilized. Currently, there is no suitable method for routine measurement of eye dose. In Thailand, the eye lens equivalent doses in terms of Hp(3) of the interventional cardiologists, nurses, and radiographers participating in interventional cardiology procedures have been measured at 12 centers since 2015 in the pilot study. The optically stimulated luminescence (OSL) dosimeter was used for measurement of the occupational exposure and the eye lens dose of 42 interventional cardiology personnel at King Chulalongkorn Memorial Hospital as one of the pilot centers. For all personnel, it is recommended that a first In Light OSL badge is placed at waist level and under the lead apron for determination of Hp(10); a second badge is placed at the collar for determination of Hp(0.07) and estimation of Hp(3). Nano Dots OSL dosimeter has been used as an eye lens dosimeter for 16 interventional cardiology personnel, both with and without lead-glass eyewear. The mean effective dose at the body, equivalent dose at the collar, and estimated eye lens dose were 0.801, 5.88, and 5.70 mSv per year, respectively. The mean eye lens dose measured by the Nano Dots dosimeter was 8.059 mSv per year on the left eye and 3.552 mSv per year on the right eye. Two of 16 interventional cardiologists received annual eye lens doses on the left side without lead glass that were higher than 20 mSv per year, the new eye lens dose limit as recommended by ICRP with the risk of eye lens opacity and cataract.

  14. Early twenty-first-century droughts during the warmest climate

    Directory of Open Access Journals (Sweden)

    Felix Kogan

    2016-01-01

    Full Text Available The first 13 years of the twenty-first century have begun with a series of widespread, long and intensive droughts around the world. Extreme and severe-to-extreme intensity droughts covered 2%–6% and 7%–16% of the world land, respectively, affecting environment, economies and humans. These droughts reduced agricultural production, leading to food shortages, human health deterioration, poverty, regional disturbances, population migration and death. This feature article is a travelogue of the twenty-first-century global and regional droughts during the warmest years of the past 100 years. These droughts were identified and monitored with the National Oceanic and Atmospheric Administration operational space technology, called vegetation health (VH, which has the longest period of observation and provides good data quality. The VH method was used for assessment of vegetation condition or health, including drought early detection and monitoring. The VH method is based on operational satellites data estimating both land surface greenness (NDVI and thermal conditions. The twenty-first-century droughts in the USA, Russia, Australia and Horn of Africa were intensive, long, covered large areas and caused huge losses in agricultural production, which affected food security and led to food riots in some countries. This research also investigates drought dynamics presenting no definite conclusion about drought intensification or/and expansion during the time of the warmest globe.

  15. Eye movement analysis for activity recognition using electrooculography.

    Science.gov (United States)

    Bulling, Andreas; Ward, Jamie A; Gellersen, Hans; Tröster, Gerhard

    2011-04-01

    In this work, we investigate eye movement analysis as a new sensing modality for activity recognition. Eye movement data were recorded using an electrooculography (EOG) system. We first describe and evaluate algorithms for detecting three eye movement characteristics from EOG signals-saccades, fixations, and blinks-and propose a method for assessing repetitive patterns of eye movements. We then devise 90 different features based on these characteristics and select a subset of them using minimum redundancy maximum relevance (mRMR) feature selection. We validate the method using an eight participant study in an office environment using an example set of five activity classes: copying a text, reading a printed paper, taking handwritten notes, watching a video, and browsing the Web. We also include periods with no specific activity (the NULL class). Using a support vector machine (SVM) classifier and person-independent (leave-one-person-out) training, we obtain an average precision of 76.1 percent and recall of 70.5 percent over all classes and participants. The work demonstrates the promise of eye-based activity recognition (EAR) and opens up discussion on the wider applicability of EAR to other activities that are difficult, or even impossible, to detect using common sensing modalities.

  16. Eye tracking in Library and Information Science

    DEFF Research Database (Denmark)

    Lund, Haakon

    2016-01-01

    Purpose The purpose of this paper is to present a systematic literature review of the application of eye-tracking technology within the field of library and information science. Eye-tracking technology has now reached a level of maturity, which makes the use of the technology more accessible....... Subsequently, a growing interest in employing eye tracking as a methodology within library and information science research must be anticipated. Design/methodology/approach The review follows the guidelines set in the Preferred Reporting Items for Systematic Reviews and Meta-Analyses recommendations. Two...... reference databases are searched for relevant references: Library and Information Science Abstracts and Library, Information Science and Technology Abstracts. The main selection criteria are peer-reviewed literature that describes the experimental setting, including which eye-tracking equipment was used...

  17. Evaluating of Tear Meniscus Parameters with Optical Coherent Tomography in Dry-Eye Patients

    Directory of Open Access Journals (Sweden)

    Gülizar Soyugelen Demirok

    2013-08-01

    Full Text Available Purpose: To evaluate the changes in meniscus parameters with optical coherence tomography (OCT after treatment and consider the correlation between the OCT parameters and dry-eye tests. Material and Method: Thirty-two dry-eye patients and 30 healthy individuals were included. Visual acuities, biomicroscopic evaluation, Schirmer-I test, tear-break-up time (T-BUT, and lower-tear meniscus parameters measured with OCT were evaluated. Ocular surface disease index (OSDI was performed. The measurements were repeated on the 10th day and 1st month of the treatment. Lower tear meniscus height (LTMH, depth (LTMD, area (LTMA and α-angle were measured. The tear meniscus parameters of the dry-eye group were compared with the control group before treatment, and the correlation between the dry-eye tests and OCT measurements were evaluated. The change in the results of the dry-eye tests and OCT measurements with treatment were assessed. Results: There was statistically no significant difference between the age and gender of the patients in groups. Before treatment the mean Schirmer-I test, TBUT and OSDI scores were different. The LTMH and LTMA were higher in the control group. In the dry-eye group before treatment, there was a negative correlation between the OSDI score and OCT parameters, however, no meaningful correlation was observed between any other test and OCT parameters. Although there were no change in LTMD and α-angle with treatment, the 1st month values of LTMH and LTMA were significantly higher from the pre-treatment and 10th day values. Discussion: When diagnosing dry-eye, TBUT and OSDI scores were found to be more effective compared to Schirmer-I test for the diagnosis of dry eye. Although not adequate by itself, tear meniscus parameters measured with OCT, LTMH and LTMA, may be helpful for evaluating the efficacy of treatment, and the correlation of these two parameters with the OSDI score may increase the objectivity while questioning the

  18. Binocular eye movement control and motion perception: What is being tracked?

    NARCIS (Netherlands)

    J. van der Steen (Hans); J. Dits (Joyce)

    2012-01-01

    textabstractPURPOSE. We investigated under what conditions humans can make independent slow phase eye movements. The ability to make independent movements of the two eyes generally is attributed to few specialized lateral eyed animal species, for example chameleons. In our study, we showed that

  19. 'An eye, for eyes - mission' - From dream to reality

    Directory of Open Access Journals (Sweden)

    Parikumar P

    2013-10-01

    shortage of donor corneas [2]. At this juncture Yokoo et al isolated and expanded corneal endothelial precursors using the sphere forming assay in vitro [3] and demonstrated the in vivo transplantation of these corneal endothelial precursors in a rabbit model of bullous keratopathy [4]. Following this, we studied the transportation of cadaver donor derived corneal endothelial tissue (CET from human cadaver donors in a thermoreversible gelation polymer (TGP (4 based transportation cocktail without cool preservation and demonstrated the viability of human corneal endothelial precursor (HCEP cells isolated from these CETs even after 72 hours of transportation without cool preservation [5]. This was done to suit the conditions existing in developing nations like India where hospitals might be located far from eye banks and maintaining cold chain preservation is relatively difficult. Further, these HCEPs were expanded in vitro using a polymer based expansion protocol [5]. This was the first step in the realisation of the dream of 'Eye for eyes' in a manner suitable for Indian conditions. Hurdle faced in Clinical Translation and its solution: After HCEP transplantation, the eye balls need to be fixed 24- 36 hours facing down, to facilitate the gravity-assisted settling of the cells injected into the anterior chamber on to the endothelium which is possible in animals but difficult in humans. To overcome this hurdle, we used the nanocomposite gel sheet (D25-NC gel sheet developed by Haraguchi [6] as a supporting material to support the HCEP cells during transplantation and the HCEP transplantation using this NC gel sheet was successfully demonstrated in a cadaver bovine's eye cornea [7]. Thus the second step in the 'Eye for eyes' mission was accomplished. The Pilot Clinical study: The study was undertaken in three patients, two suffering from bullous keratopathy and one patient with congenital corneal dystrophy after proper informed consent. The right eye was affected in each

  20. STUDY OF PREVALENCE OF DRY EYE IN DIABETES

    Directory of Open Access Journals (Sweden)

    Vivek Mahadev Sahasrabudhe

    2017-06-01

    Full Text Available BACKGROUND Diabetes causes blindness in 20-74 year old persons. Blindness in diabetic patients may due to cataract or retinopathy. Dry eye is one of the ocular surface problem increasingly observed in diabetic patients. This study was performed to assess the prevalence of dry eye syndrome in type 2 diabetic patients and their contributing factors. MATERIALS AND METHODS A cross-sectional study was done between April 2016 to September 2016. 70 patients of type 2 diabetes diagnosed at Dr. Shankarrao Chavan Government Hospital, Nanded, were included in this study. Patients were assessed by questionnaire about other diseases and drugs. Dry eye syndrome was assessed with Tear Breakup Time (TBUT, Schirmer's test, lissamine green staining apart from routine ophthalmic examination. RESULTS Out of 60 patients, 32 (53% suffer from dry eye syndrome. CONCLUSION Diabetes and dry eyes appear to have a common association. Further studies need to be undertaken to establish an aetiologic relationship. As routine dilated fundus examination is an integral part of evaluation of diabetic patients in ophthalmic clinics, examination for dry eye should also be an integral part of the assessment of diabetic eye disease.

  1. Eye Movements During Everyday Behavior Predict Personality Traits.

    Science.gov (United States)

    Hoppe, Sabrina; Loetscher, Tobias; Morey, Stephanie A; Bulling, Andreas

    2018-01-01

    Besides allowing us to perceive our surroundings, eye movements are also a window into our mind and a rich source of information on who we are, how we feel, and what we do. Here we show that eye movements during an everyday task predict aspects of our personality. We tracked eye movements of 42 participants while they ran an errand on a university campus and subsequently assessed their personality traits using well-established questionnaires. Using a state-of-the-art machine learning method and a rich set of features encoding different eye movement characteristics, we were able to reliably predict four of the Big Five personality traits (neuroticism, extraversion, agreeableness, conscientiousness) as well as perceptual curiosity only from eye movements. Further analysis revealed new relations between previously neglected eye movement characteristics and personality. Our findings demonstrate a considerable influence of personality on everyday eye movement control, thereby complementing earlier studies in laboratory settings. Improving automatic recognition and interpretation of human social signals is an important endeavor, enabling innovative design of human-computer systems capable of sensing spontaneous natural user behavior to facilitate efficient interaction and personalization.

  2. Eye Movements During Everyday Behavior Predict Personality Traits

    Directory of Open Access Journals (Sweden)

    Sabrina Hoppe

    2018-04-01

    Full Text Available Besides allowing us to perceive our surroundings, eye movements are also a window into our mind and a rich source of information on who we are, how we feel, and what we do. Here we show that eye movements during an everyday task predict aspects of our personality. We tracked eye movements of 42 participants while they ran an errand on a university campus and subsequently assessed their personality traits using well-established questionnaires. Using a state-of-the-art machine learning method and a rich set of features encoding different eye movement characteristics, we were able to reliably predict four of the Big Five personality traits (neuroticism, extraversion, agreeableness, conscientiousness as well as perceptual curiosity only from eye movements. Further analysis revealed new relations between previously neglected eye movement characteristics and personality. Our findings demonstrate a considerable influence of personality on everyday eye movement control, thereby complementing earlier studies in laboratory settings. Improving automatic recognition and interpretation of human social signals is an important endeavor, enabling innovative design of human–computer systems capable of sensing spontaneous natural user behavior to facilitate efficient interaction and personalization.

  3. Greater Proptosis Is Not Associated With Improved Compressive Optic Neuropathy in Thyroid Eye Disease.

    Science.gov (United States)

    Nanda, Tavish; Dunbar, Kristen E; Campbell, Ashley A; Bathras, Ryan M; Kazim, Michael

    2018-05-18

    Despite the paucity of supporting data, it has generally been held that proptosis in thyroid eye disease (TED) may provide relative protection from compressive optic neuropathy (CON) by producing spontaneous decompression. The objective of this study was to investigate this phenomenon in patients with bilateral TED-CON. We retrospectively reviewed the charts of 67 patients (134 orbits) with bilateral TED-CON at Columbia-Presbyterian Medical Center. Significant asymmetric proptosis (Hertel) was defined as ≥ 2 mm. Significant asymmetric CON was defined first, as the presence of an relative afferent pupillary defect. Those without an relative afferent pupillary defect were evaluated according to the TED-CON formula y = -0.69 - 0.31 × (motility) - 0.2 × (mean deviation) - 0.02 × (color vision) as previously established for the diagnosis of TED-CON. A difference in the formula result ≥ 1.0 between eyes was considered significant. Patients were then divided into 4 groups. Forty-one of 67 patients demonstrated asymmetric CON (29 by relative afferent pupillary defect, 12 by formula). Twenty-one of 67 patients demonstrated asymmetric proptosis. Only 5 of 12 (41.6%) of the patients who had both asymmetric proptosis and asymmetric CON (group 1) showed greater proptosis in the eye with less CON. Twenty-nine patients (group 2) showed that asymmetric CON occurred despite symmetrical proptosis. Seventeen patients (group 3), showed the inverse, that asymmetric differences in proptosis occurred with symmetrical CON. Despite commonly held assumptions, our results suggest that greater proptosis is not associated with improved TED-CON. Combining groups 1 to 3-all of which demonstrated asymmetry of either proptosis, CON, or both-91.4% of patients did not show a relationship between greater proptosis and improved CON.

  4. Effect of 0.5g/L cyclosporine A for symptom and sign scores in patients with moderate to severe dry eye

    Directory of Open Access Journals (Sweden)

    Su-Ying Yu

    2016-05-01

    Full Text Available AIM:To investigate the effect of 0.5g/L cyclosporine A for symptom and sign scores in patients with moderate to severe dry eye.METHODS:Eighty patients(160 eyeswith moderate to severe dry eye were divided into two groups by double-blind and random principles:40 patients(80 eyesin observation group were treated with 10g/L sodium carboxymethyl cellulose and 0.5g/L cyclosporine A eye drops, 40 patients(80 eyesin the control group were treated with 10g/L sodium carboxymethyl cellulose eye drops. The changes of ocular sign and symptom scores were compared between the two groups.RESULTS:The total effective rate of observation group was 95.0%, which was significantly higher than that of control group(85.0%, PPPP>0.05. After treatment, the four parameters of observation group were improved significantly(PPPCONCLUSION:The 0.5g/L cyclosporine A eye drops can effectively relieve the symptoms and signs of moderate to severe dry eye, promote tear secretion, and improve ocular surface environment. The treatment effect is good.

  5. Evaluation of refractive correction for standard automated perimetry in eyes wearing multifocal contact lenses.

    Science.gov (United States)

    Hirasawa, Kazunori; Ito, Hikaru; Ohori, Yukari; Takano, Yui; Shoji, Nobuyuki

    2017-01-01

    To evaluate the refractive correction for standard automated perimetry (SAP) in eyes with refractive multifocal contact lenses (CL) in healthy young participants. Twenty-nine eyes of 29 participants were included. Accommodation was paralyzed in all participants with 1% cyclopentolate hydrochloride. SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions: monofocal CL corrected for near distance (baseline); multifocal CL corrected for distance (mCL-D); and mCL-D corrected for near vision using a spectacle lens (mCL-N). Primary outcome measures were the foveal threshold, mean deviation (MD), and pattern standard deviation (PSD). The foveal threshold of mCL-N with both the 24-2 and 10-2 protocols significantly decreased by 2.2-2.5 dB ( P correction without additional near correction is to be recommended.

  6. A novel method for observation by unaided eyes of nitrogen ion tracks and angular distribution in a plasma focus device using 50 Hz–HV electrochemically-etched polycarbonate detectors

    International Nuclear Information System (INIS)

    Sohrabi, M.; Habibi, M.; Roshani, G.H.; Ramezani, V.

    2012-01-01

    A novel ion detection method has been developed and studied in this paper for the first time to detect and observe tracks of nitrogen ions and their angular distribution by unaided eyes in the Amirkabir 4 kJ plasma focus device (PFD). The method is based on electrochemical etching (ECE) of nitrogen ion tracks in 1 mm thick large area polycarbonate (PC) detectors. The ECE method employed a specially designed and constructed large area ECE chamber by applying a 50 Hz–high voltage (HV) generator under optimized ECE conditions. The nitrogen ion tracks and angular distribution were efficiently (constructed for this study) amplified to a point observable by the unaided eyes. The beam profile and angular distribution of nitrogen ion tracks in the central axes of the beam and two- and three-dimensional iso-ion track density distributions showing micro-beam spots were determined. The distribution of ion track density along the central axes versus angular position shows double humps around a dip at the 0° angular positions. The method introduced in this paper proved to be quite efficient for ion beam profile and characteristic studies in PFDs with potential for ion detection studies and other relevant dosimetry applications.

  7. Radiation effects on eye components

    International Nuclear Information System (INIS)

    Durchschlag, H.; Fochler, C.; Abraham, K.; Kulawik, B.

    1998-01-01

    The radiation damage (X-ray, UV light) of the most important components of the vertebrate eye (crystallins and other proteins, hyaluronic acid, vitreous, aqueous humour, ascorbic acid) has been investigated by various methods of physical chemistry. UV absorption and fluorescence spectroscopy as well as circular dichroism unveiled changes of the chromophores/fluorophores of the constituent biopolymers and low-molecular components, together with alterations of helix content and the occurrence of aggregation. Size-exclusion chromatography, analytical ultracentrifugation, densimetry, viscometry and light scattering experiments monitored changes of the global structure of proteins and polysaccharides involved. Electrophoreses allowed conclusions on fragmentation, unfolding and crosslinking. Analytical methods provided information regarding the integrity of groups of special concern (SH, SS) and revealed the existence of stable noxious species (H 2 O 2 ). By means of various measures and additives, manifold modifications of the impact of both ionizing and nonionizing radiation may be achieved. Caused by differences in the primary reactions, eye polymers are protected efficaciously by typical OH radical scavengers against X-irradiation, whereas compounds which exhibit absorption behavior in the UV range turn out to act as potent protectives ('chemical filters') against UV light. A few substances, such as ascorbate, are able to provide protection against both sorts of radiation and are even able to exhibit a slight chemical repair of already damaged particles. The results obtained are of importance for understanding pathological alterations of the eye (loss of transparency, cataractogenesis) and for developing new strategies for protection and repair of eye components. (author)

  8. The Choroidal Eye Oximeter - An instrument for measuring oxygen saturation of choroidal blood in vivo

    Science.gov (United States)

    Laing, R. A.; Danisch, L. A.; Young, L. R.

    1975-01-01

    The Choroidal Eye Oximeter is an electro-optical instrument that noninvasively measures the oxygen saturation of choroidal blood in the back of the human eye by a spectrophotometric method. Since choroidal blood is characteristic of blood which is supplied to the brain, the Choroidal Eye Oximeter can be used to monitor the amount of oxygen which is supplied to the brain under varying external conditions. The instrument consists of two basic systems: the optical system and the electronic system. The optical system produces a suitable bi-chromatic beam of light, reflects this beam from the fundus of the subject's eye, and onto a low-noise photodetector. The electronic system amplifies the weak composite signal from the photodetector, computes the average oxygen saturation from the area of the fundus that was sampled, and displays the value of the computed oxygen saturation on a panel meter.

  9. EDEL: ENEA dosemeter for eye lens

    International Nuclear Information System (INIS)

    Ferrari, Paolo; Mariotti, Francesca; Campani, Lorenzo

    2016-01-01

    Since the publication of International Commission on Radiological Protection statement in 2011 on tissue reaction, eye lens radiation protection played an important role in exposed personnel dosimetry. For this reason, the Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA) Individual Monitoring Service decided to study a prototype to fulfil specific requests (e.g. for survey in interventional department and intercomparisons). On the basis of such preliminary investigation, a new eye lens dosemeter was developed. The new dosemeter, named EDEL (ENEA Dosemeter for Eye Lens), was characterised in terms of H p (3), the operational quantity related to eye lens monitoring. The investigation was performed experimentally and optimised using the Monte Carlo MCNP6 code. The new prototype was thought to fulfil two main requests: the reliability of the dosimetric data and the portability of the dosemeter itself. The new dosemeter will soon be supplied to the collaborating hospitals for workplace test measurements. (authors)

  10. Determining the frequency of dry eye in computer users and comparing with control group

    Directory of Open Access Journals (Sweden)

    Mohammad Hossein Davari

    2017-08-01

    Full Text Available AIM: To determine the frequency of dry eye in computer users and to compare them with control group. METHODS: This study was a case control research conducted in 2015 in the city of Birjand. Sample size of study was estimated to be 304 subjects(152 subjects in each group, computer user group and control group. Non-randomized method of sampling was used in both groups. Schirmer test was used to evaluate dry eye of subjects. Then, subjects completed questionnaire. This questionnaire was developed based on objectives and reviewing the literature. After collecting the data, they were entered to SPSS Software and they were analyzed using Chi-square test or Fisher's test at the alpha level of 0.05.RESULTS: In total, 304 subjects(152 subjects in each groupwere included in the study. Frequency of dry eyes in the control group was 3.3%(5 subjectsand it was 61.8% in computer users group(94 subjects. Significant difference was observed between two groups in this regard(Pn=12, and it was 34.2% in computer users group(n=52, which significant difference was observed between two groups in this regard(PP=0.8. The mean working hour with computer per day in patients with dry eye was 6.65±3.52h, while it was 1.62±2.54h in healthy group(T=13.25, PCONCLUSION: This study showed a significant relationship between using computer and dry eye and ocular symptoms. Thus, it is necessary that officials need to pay particular attention to working hours with computer by employees. They should also develop appropriate plans to divide the working hours with computer among computer users. However, due to various confounding factors, it is recommended that these factors to be controlled in future studies.

  11. Attentional biases in body dysmorphic disorder (BDD): Eye-tracking using the emotional Stroop task.

    Science.gov (United States)

    Toh, Wei Lin; Castle, David J; Rossell, Susan L

    2017-04-01

    Body dysmorphic disorder (BDD) is characterised by repetitive behaviours and/or mental acts occurring in response to preoccupations with perceived defects or flaws in physical appearance. This study aimed to examine attentional biases in BDD via the emotional Stroop task with two modifications: i) incorporating an eye-tracking paradigm, and ii) employing an obsessive-compulsive disorder (OCD) control group. Twenty-one BDD, 19 OCD and 21 HC participants, who were age-, sex-, and IQ-matched, were included. A card version of the emotional Stroop task was employed based on seven 10-word lists: (i) BDD-positive, (ii) BDD-negative, (iii) OCD-checking, (iv) OCD-washing, (v) general positive, (vi) general threat, and (vii) neutral (as baseline). Participants were asked to read aloud words and word colours consecutively, thereby yielding accuracy and latency scores. Eye-tracking parameters were also measured. Participants with BDD exhibited significant Stroop interference for BDD-negative words relative to HC participants, as shown by extended colour-naming latencies. In contrast, the OCD group did not exhibit Stroop interference for OCD-related nor general threat words. Only mild eye-tracking anomalies were uncovered in clinical groups. Inspection of individual scanning styles and fixation heat maps however revealed that viewing strategies adopted by clinical groups were generally disorganised, with avoidance of certain disorder-relevant words and considerable visual attention devoted to non-salient card regions. The operation of attentional biases to negative disorder-specific words was corroborated in BDD. Future replication studies using other paradigms are vital, given potential ambiguities inherent in emotional Stroop task interpretation. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Burning Eye Syndrome: Do Neuropathic Pain Mechanisms Underlie Chronic Dry Eye?

    Science.gov (United States)

    Kalangara, Jerry P; Galor, Anat; Levitt, Roy C; Felix, Elizabeth R; Alegret, Ramon; Sarantopoulos, Constantine D

    2016-04-01

    Dry eye is a multi-factorial disorder that manifests with painful ocular symptoms and visual disturbances, which can only be partly attributed to tear dysfunction. This disorder may also involve neuroplasticity in response to neuronal injury. This review will emphasize the key characteristics of dry eye pain and its pathologic mechanisms, making the argument that a subset of dry eye represents a neuropathic pain disorder of the eye, more appropriately called "burning eye syndrome." A literature review was conducted using a PubMed search focusing on dry eye, corneal nociception, and neuropathic pain. Articles were reviewed and those discussing clinical course, pathophysiology, and neuronal regulation of chronic ocular pain as related to dry eye were summarized. We found that there is a discordance between ocular pain and dryness on the ocular surface. Although tear dysfunction may be one of the initial insults, its persistence may be associated with repeated ocular sensory nerve injury leading to an acute-to-chronic pain transition associated with neuropathologic changes (peripheral and central sensitization), neuronal dysfunction, and spontaneous ocular pain. Dry eye is becoming a major health concern due to its increasing incidence, significant morbidity, and economic burden. Recent evidence suggests that a subset of dry eye may be better represented as a chronic neuropathic pain disorder due to its features of dysesthesia, spontaneous pain, allodynia, and hyperalgesia. Future therapies targeted at the underlying neuroplasticity may yield improved efficacy for patients with this subset of dry eye, which we term "burning eye syndrome." © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  13. The Watching-Eye Effect on Prosocial Lying

    Directory of Open Access Journals (Sweden)

    Ryo Oda

    2015-07-01

    Full Text Available Evidence shows that people tend to behave prosocially when they are in the presence of images depicting eyes. There are two proximate causes of the eyes effect. One involves positive motivation to gain future reward and the other involves negative motivation to avoid violating a norm. Although several studies have suggested that positive motivation is a strong candidate, these studies were unable to distinguish between adherence to norms and prosocial behavior. We investigated the watching-eyes effect in an experimental setting to determine whether the tendency of humans to violate norms voluntarily could be understood as prosocial behavior. We compared the tendency to tell “prosocial lies” in the presence of a depiction of stylized eyes (eyes condition with that involving no such depiction (control condition. Under the control condition, participants tended to tell lies that benefitted others, whereas the tendency toward prosocial lying disappeared under the eyes condition. This suggests that the desire to avoid violating norms by being honest is stronger than the desire to pursue a good reputation by demonstrating generosity when such violation might lead to serious costs.

  14. Fluorescein eye stain

    Science.gov (United States)

    Abnormal results may point to: Abnormal tear production (dry eye) Blocked tear duct Corneal abrasion (a scratch on ... object in eye ) Infection Injury or trauma Severe dry eye associated with arthritis (keratoconjunctivitis sicca)

  15. Comparative Case Study of Diffusion of Eye Movement Desensitization and Reprocessing in Two Clinical Settings: Empirically Supported Treatment Status Is Not Enough

    NARCIS (Netherlands)

    Cook, Joan M.; Biyanova, Tatyana; Coyne, James C.

    2009-01-01

    An in-depth comparative case study was conducted of two attempts at diffusion of an empirically supported, but controversial, psychotherapy: eye movement desensitization and reprocessing (EMDR). One Department of Veterans Affairs (VA) treatment setting in which there was substantial uptake was

  16. Evaluation of a remote webcam-based eye tracker

    DEFF Research Database (Denmark)

    Skovsgaard, Henrik; Agustin, Javier San; Johansen, Sune Alstrup

    2011-01-01

    In this paper we assess the performance of an open-source gaze tracker in a remote (i.e. table-mounted) setup, and compare it with two other commercial eye trackers. An experiment with 5 subjects showed the open-source eye tracker to have a significantly higher level of accuracy than one...

  17. Comparison of intraocular pressure measured by non-contact air puff versus Goldmann applanation tonometers in gas-filled vitrectomized eyes.

    Science.gov (United States)

    Patikulsila, Direk; Taweemankongsab, Srisuda; Ngamtipakorn, Supob

    2003-05-01

    To compare intraocular pressure (IOP) measured by two different instruments, air puff tonometer (APT) versus Goldmann applanation tonometer (GAT), in gas-filled vitrectomized eyes. Three-month, prospective, comparative trial. Thirty-eight patients (38 eyes), who underwent a pars plana vitrectomy (PPV) with gas injection, were enrolled in the study. The IOP was measured by an APT, followed by GAT within 10 minutes by two different, masked investigators. IOPs were measured by two methods and then were compared. Overall, there was a high correlation between both measurements (r = 0.908, p 0.05). By a subgroup analysis of 17 eyes with IOP measured by a GAT of 21 mmHg or less, the APT readings (15.28 +/- 4.81) and GAT readings (14.47 +/- 3.89) were not significantly different (p > 0.05). Of 21 eyes, with IOP measured by a GAT of 22 mmHg or more, the APT readings (26.88 +/- 8.81) were significantly lower than those obtained by the GAT (29.62 +/- 7.69) (p < 0.05). In gas-filled vitrectomized eyes, IOP measurements obtained by an APT correlated well with those obtained by GAT, especially when the IOP was within normal range. However, in eyes with elevated IOP, the APT significantly underestimated the IOP measurement when compared to the gold standard, GAT.

  18. Late dislocation of in-the-bag intraocular lenses in uveitic eyes: An analysis of management and complications

    Directory of Open Access Journals (Sweden)

    Sudha K Ganesh

    2017-01-01

    Full Text Available Aim: An analysis of late in-the-bag dislocation of intraocular lenses (IOL, in uveitic eyes. Setting: Referral uveitis clinic. Design: Retrospective case series. Materials and Methods: All case records of eyes with chronic uveitis that had phacoemulsification with IOL implantation, at a referral uveitis clinic between February 1997 and January 2015 were retrieved and analyzed. Only those eyes with no documented intraoperative complication and no predisposing risks to IOL dislocation, such as pseudoexfoliation, high myopia, trauma, and prior VR surgery were included in this study. Results: A total of 581 eyes with chronic uveitis underwent phacoemulsification with IOL implantation under steroid cover from February 1997 to December 2015. Out of these 581 eyes, 10 patients (11 eyes had experienced late in-the-bag IOL dislocation (1.89%. All 11 eyes had chronic intermediate uveitis. The mean duration from the time of cataract surgery to IOL dislocation was 11.24 years. 5 out of 11 eyes had pars plana vitrectomy (PPV with IOL removal with 4-point sutured scleral fixated IOL. Two out of 11 eyes had PPV with in-the-bag IOL re-fixation. Out of 11, 2 eyes had PPV with IOL removal only. Remaining 2 eyes of 2 patients did not opt for surgery. Out of 11, 8 eyes had improved vision at last follow-up. Conclusions: In-the-bag dislocation of IOL is a rare late complication in uveitic eyes. With tight perioperative inflammatory control, scleral-fixated posterior chamber intraocular lens or IOL re-fixation are good options of restoring vision in these high-risk eyes.

  19. Morphology of the eye of the southern right whales (Eubalaena australis).

    Science.gov (United States)

    Buono, Mónica R; Fernández, Marta S; Herrera, Yanina

    2012-02-01

    Recently, there has been a growing interest in the anatomy and optics of the visual system of cetaceans. However, much of the new information has been focused on odontocetes, and relatively little is known about the visual anatomy of baleen whales. The aim of this study was describe the eye anatomy of the southern right whale (Eubalaena australis). Eye samples were collected from 26 calves, four adults with known body length, as well as two specimens of unknown body length that had stranded near their nursery ground at Península Valdés, Argentina, over 6 years. We provide anatomical descriptions of the eyeball and extraocular structures, as well as quantitative data in the form of eyeball, corneal, scleral, and lens measurements. To explore the sensitivity of the eye to light, the f-number was estimated in one specimen. We found that the eyes of the calves differed from those of the adults in having less periorbital fat surrounding the eyeball. We also observed variations in the abundance of periorbital fat among the adult specimens. The regression analysis revealed a correlation between body length and eyeball size. By contrast, the dimensions of the cornea were only weakly correlated with body length. The estimated f-number suggests that the optical sensitivity of the Eubalaena australis eye is relatively low. However, caution had to be taken in interpreting f-number as a proxy of eye sensitivity because it depends on the lens size, which can be affected by the fixation methods used. Copyright © 2011 Wiley Periodicals, Inc.

  20. Genuine eye contact elicits self-referential processing.

    Science.gov (United States)

    Hietanen, Jonne O; Hietanen, Jari K

    2017-05-01

    The effect of eye contact on self-awareness was investigated with implicit measures based on the use of first-person singular pronouns in sentences. The measures were proposed to tap into self-referential processing, that is, information processing associated with self-awareness. In addition, participants filled in a questionnaire measuring explicit self-awareness. In Experiment 1, the stimulus was a video clip showing another person and, in Experiment 2, the stimulus was a live person. In both experiments, participants were divided into two groups and presented with the stimulus person either making eye contact or gazing downward, depending on the group assignment. During the task, the gaze stimulus was presented before each trial of the pronoun-selection task. Eye contact was found to increase the use of first-person pronouns, but only when participants were facing a real person, not when they were looking at a video of a person. No difference in self-reported self-awareness was found between the two gaze direction groups in either experiment. The results indicate that eye contact elicits self-referential processing, but the effect may be stronger, or possibly limited to, live interaction. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Why the American public supports twenty-first century learning.

    Science.gov (United States)

    Sacconaghi, Michele

    2006-01-01

    Aware that constituent support is essential to any educational endeavor, the AOL Time Warner Foundation (now the Time Warner Foundation), in conjunction with two respected national research firms, measured Americans' attitudes toward the implementation of twenty-first century skills. The foundation's national research survey was intended to explore public perceptions of the need for changes in the educational system, in school and after school, with respect to the teaching of twenty-first century skills. The author summarizes the findings of the survey, which were released by the foundation in June 2003. One thousand adults were surveyed by telephone, including African Americans, Latinos, teachers, and business executives. In general, the survey found that Americans believe today's students need a "basics-plus" education, meaning communication, technology, and critical thinking skills in addition to the traditional basics of reading, writing, and math. In fact, 92 percent of respondents stated that students today need different skills from those of ten to twenty years ago. Also, after-school programs were found to be an appropriate vehicle to teach these skills. Furthermore, the survey explored how well the public perceives schools to be preparing youth for the workforce and postsecondary education, which twenty-first century skills are seen as being taught effectively, and the level of need for after-school and summer programs. The survey results provide conclusive evidence of national support for basics-plus education. Thus, a clear opportunity exists to build momentum for a new model of education for the twenty-first century.

  2. Glaucoma: Eye-to-Eye with Dr. Rachel Bishop

    Science.gov (United States)

    ... of this page please turn JavaScript on. Feature: Glaucoma Eye-to-Eye with Dr. Rachel Bishop Past ... nerves are pale and cupped—signs of advanced glaucoma. Yet the patient wasn't aware of any ...

  3. Outlook: The Next Twenty Years

    Energy Technology Data Exchange (ETDEWEB)

    Murayama, Hitoshi

    2003-12-07

    I present an outlook for the next twenty years in particle physics. I start with the big questions in our field, broken down into four categories: horizontal, vertical, heaven, and hell. Then I discuss how we attack the bigquestions in each category during the next twenty years. I argue for a synergy between many different approaches taken in our field.

  4. Release of Fluconazole from Contact Lenses Using a Novel In Vitro Eye Model.

    Science.gov (United States)

    Phan, Chau-Minh; Bajgrowicz, Magdalena; Gao, Huayi; Subbaraman, Lakshman N; Jones, Lyndon W

    2016-04-01

    Rapid drug release followed by a plateau phase is a common observation with drug delivery from contact lenses (CLs) when evaluated in a vial. The aim of this study was to compare the release of fluconazole from seven commercially available daily disposable CLs using a conventional vial-based method with a novel in vitro eye model. An eye model was created using two 3-dimensional printed molds, which were filled with polydimethylsiloxane to obtain an inexpensive model that would mimic the eyeball and eyelid. The model was integrated with a microfluidic syringe pump, and the flow-through was collected in a 12-well microliter plate. Four commercial daily disposable conventional hydrogels (nelfilcon A, omafilcon A, etafilcon A, ocufilcon B) and three silicone hydrogels (somofilcon A, narafilcon A, delefilcon A) were evaluated. These CLs were incubated with fluconazole for 24 h. The drug release was measured in a vial containing 4.8 mL of phosphate-buffered saline and in the polydimethylsiloxane eye model with a 4.8-mL tear flow across 24 h. Overall, conventional hydrogel CLs had a higher uptake and release of fluconazole than silicone hydrogel CLs (p eye model (p eye model under low tear volume was sustained and did not reach a plateau across 24 h (p eyes with fungal keratitis may have increased tearing, which would significantly accelerate drug release.

  5. Visual straight-ahead preference in saccadic eye movements.

    Science.gov (United States)

    Camors, Damien; Trotter, Yves; Pouget, Pierre; Gilardeau, Sophie; Durand, Jean-Baptiste

    2016-03-15

    Ocular saccades bringing the gaze toward the straight-ahead direction (centripetal) exhibit higher dynamics than those steering the gaze away (centrifugal). This is generally explained by oculomotor determinants: centripetal saccades are more efficient because they pull the eyes back toward their primary orbital position. However, visual determinants might also be invoked: elements located straight-ahead trigger saccades more efficiently because they receive a privileged visual processing. Here, we addressed this issue by using both pro- and anti-saccade tasks in order to dissociate the centripetal/centrifugal directions of the saccades, from the straight-ahead/eccentric locations of the visual elements triggering those saccades. Twenty participants underwent alternating blocks of pro- and anti-saccades during which eye movements were recorded binocularly at 1 kHz. The results confirm that centripetal saccades are always executed faster than centrifugal ones, irrespective of whether the visual elements have straight-ahead or eccentric locations. However, by contrast, saccades triggered by elements located straight-ahead are consistently initiated more rapidly than those evoked by eccentric elements, irrespective of their centripetal or centrifugal direction. Importantly, this double dissociation reveals that the higher dynamics of centripetal pro-saccades stem from both oculomotor and visual determinants, which act respectively on the execution and initiation of ocular saccades.

  6. Three-Dimensional Eye Tracking in a Surgical Scenario.

    Science.gov (United States)

    Bogdanova, Rositsa; Boulanger, Pierre; Zheng, Bin

    2015-10-01

    Eye tracking has been widely used in studying the eye behavior of surgeons in the past decade. Most eye-tracking data are reported in a 2-dimensional (2D) fashion, and data for describing surgeons' behaviors on stereoperception are often missed. With the introduction of stereoscopes in laparoscopic procedures, there is an increasing need for studying the depth perception of surgeons under 3D image-guided surgery. We developed a new algorithm for the computation of convergence points in stereovision by measuring surgeons' interpupillary distance, the distance to the view target, and the difference between gaze locations of the 2 eyes. To test the feasibility of our new algorithm, we recruited 10 individuals to watch stereograms using binocular disparity and asked them to develop stereoperception using a cross-eyed viewing technique. Participants' eye motions were recorded by the Tobii eye tracker while they performed the trials. Convergence points between normal and stereo-viewing conditions were computed using the developed algorithm. All 10 participants were able to develop stereovision after a short period of training. During stereovision, participants' eye convergence points were 14 ± 1 cm in front of their eyes, which was significantly closer than the convergence points under the normal viewing condition (77 ± 20 cm). By applying our method of calculating convergence points using eye tracking, we were able to elicit the eye movement patterns of human operators between the normal and stereovision conditions. Knowledge from this study can be applied to the design of surgical visual systems, with the goal of improving surgical performance and patient safety. © The Author(s) 2015.

  7. Video Conference System that Keeps Mutual Eye Contact Among Participants

    Directory of Open Access Journals (Sweden)

    Masahiko Yahagi

    2011-10-01

    Full Text Available A novel video conference system is developed. Suppose that three people A, B, and C attend the video conference, the proposed system enables eye contact among every pair. Furthermore, when B and C chat, A feels as if B and C were facing each other (eye contact seems to be kept among B and C. In the case of a triangle video conference, the respective video system is composed of a half mirror, two video cameras, and two monitors. Each participant watches other participants' images that are reflected by the half mirror. Cameras are set behind the half mirror. Since participants' image (face and the camera position are adjusted to be the same direction, eye contact is kept and conversation becomes very natural compared with conventional video conference systems where participants' eyes do not point to the other participant. When 3 participants sit at the vertex of an equilateral triangle, eyes can be kept even for the situation mentioned above (eye contact between B and C from the aspect of A. Eye contact can be kept not only for 2 or 3 participants but also any number of participants as far as they sit at the vertex of a regular polygon.

  8. About the Eye

    Medline Plus

    Full Text Available ... Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision ... to More Information Optical Illusions Printables About the Eye Your eyes are made up of many different ...

  9. About the Eye

    Medline Plus

    Full Text Available ... your eye. It helps your eye focus light so things look sharp and clear. Sclera (SKLEH-ruh) ... the different parts of your eye work together so you can see and make sense of the ...

  10. Eye absence does not regulate planarian stem cells during eye regeneration

    OpenAIRE

    LoCascio, Samuel A.; Lapan, Sylvain W.; Reddien, Peter W.

    2017-01-01

    Dividing cells called neoblasts contain pluripotent stem cells and drive planarian flatworm regeneration from diverse injuries. A long-standing question is whether neoblasts directly sense and respond to the identity of missing tissues during regeneration. We used the eye to investigate this question. Surprisingly, eye removal was neither sufficient nor necessary for neoblasts to increase eye progenitor production. Neoblasts normally increase eye progenitor production following decapitation, ...

  11. An integrative model for the neural mechanism of Eye Movement Desensitization and Reprocessing (EMDR

    Directory of Open Access Journals (Sweden)

    Olivier A. Coubard

    2016-04-01

    Full Text Available Since the seminal report by Shapiro that bilateral stimulation induces cognitive and emotional changes, twenty-six years of basic and clinical research have examined the effects of Eye Movement Desensitization and Reprocessing (EMDR in anxiety disorders, particularly in Post-Traumatic Stress Disorder (PTSD. The present article aims at better understanding EMDR neural mechanism. I first review procedural aspects of EMDR protocol and theoretical hypothesis about EMDR effects, and develop the reasons why the scientific community is still divided about EMDR. I then slide from psychology to physiology describing eye movements/emotion interaction from the physiological viewpoint, and introduce theoretical and technical tools used in movement research to re-examine EMDR neural mechanism. Using a recent physiological model for the neuropsychological architecture of motor and cognitive control, the Threshold Interval Modulation with Early Release-Rate of rIse Deviation with Early Release – TIMER-RIDER – model, I explore how attentional control and bilateral stimulation may participate to EMDR effects. These effects may be obtained by two processes acting in parallel: (i activity level enhancement of attentional control component; and (ii bilateral stimulation in any sensorimotor modality, both resulting in lower inhibition enabling dysfunctional information to be processed and anxiety to be reduced. The TIMER-RIDER model offers quantitative predictions about EMDR effects for future research about its underlying physiological mechanisms.

  12. Eye contact facilitates awareness of faces during interocular suppression

    NARCIS (Netherlands)

    Stein, T.; Senju, A.; Peelen, M.V.; Sterzer, P.

    Eye contact captures attention and receives prioritized visual processing. Here we asked whether eye contact might be processed outside conscious awareness. Faces with direct and averted gaze were rendered invisible using interocular suppression. In two experiments we found that faces with direct

  13. Relating Eye Activity Measures to Human Controller Remnant Characteristics

    NARCIS (Netherlands)

    Popovici, A; Zaal, P.M.T.; Pool, D.M.; Mulder, M.; Sawaragi, T

    2016-01-01

    This study attempts to partially explain the characteristics of the human perceptual remnant, following Levison’s representation of the remnant as an equivalent observation noise. Eye activity parameters are recorded using an eye tracker in two compensatory tracking tasks in which the visual

  14. [Preimplantation genetic diagnosis and monogenic inherited eye diseases].

    Science.gov (United States)

    Hlavatá, L; Ďuďáková, Ľ; Trková, M; Soldátová, I; Skalická, P; Kousal, B; Lišková, P

    Preimplantation genetic diagnosis (PGD) is an established application of genetic testing in the context of in vitro fertilization. PGD is an alternative method to prenatal diagnosis which aims to prevent the transmission of an inherited disorder to the progeny by implanting only embryos that do not carry genetic predisposition for a particular disease. The aim of this study is to provide an overview of eye disorders for which PGD has been carried out. The European literature search focused on best practices, ethical issues, risks and results of PGD for inherited eye disorders. PGD is performed for a number of ocular disorders; a prerequisite for its application is however, the knowledge of a disease-causing mutation(s). The main advantage of this method is that the couple is not exposed to a decision of whether or not to undergo an abortion. Qualified counselling must be provided prior to the PGD in order to completely understand the risk of disability in any child conceived, consequences of disease manifestation, and advantages as well as limitations of this method. In the group of non-syndromic eye diseases and diseases in which ocular findings dominate, PGD has been performed in European countries for aniridia, choroideremia, congenital fibrosis of extraocular muscles, Leber congenital amaurosis, ocular albinism, retinitis pigmentosa, X-linked retinoschisis, Stargardt disease, blepharophimosis-ptosis-inverse epicanthus syndrome and retinoblastoma. Sexing for X-linked or mitochondrial diseases has been carried out for blue cone monochromatism, choroideremia, familial exudative vitreoretinopathy, Leber hereditary optic neuropathy, macular dystrophy (not further specified), Norrie disease, X-linked congenital stationary night blindness, X-linked retinoschisis and nystagmus (not further specified). In recent years, there has been an increase in potential to use PGD. The spectrum of diseases for this method has widened to include severe inherited eye diseases

  15. Christoph Scheiner's eye studies.

    Science.gov (United States)

    Daxecker, F

    1992-01-01

    Christoph Scheiner was born in 1573 or 1575. In 1595 he entered into the Order of the Jesuits; he died in 1650. In 1619 his book Oculus, dealing with the optics of the eye, appeared in Innsbruck. The invention of the telescope was of utmost importance for progress in astronomical and physical research. Scheiner himself built telescopes and discovered the sunspots. As a result, an unpleasant priority dispute with Galilei ensued. From 1624 onwards, Scheiner was in Rome, where his main work Rosa Ursina was published in 1630. A part of this book deals with the physiological optics of the eye as well. Some of his discoveries and experiments are taken from these two books: determination of the radius of curvature of the cornea, discovery of the nasal exit of the optic nerve, increase in the radius of curvature of the lens in case of accommodation, Scheiner's procedure (double images with ametropia), refractive indices of various parts of the eye, Scheiner's experiment. Without any doubt, Christoph Scheiner belongs to the foremost scientists of the first half of the 17th century.

  16. A clinical study of the efficacy of topical corticosteroids on dry eye

    OpenAIRE

    Yang, Chong-qing; Sun, Wen; Gu, Yang-shun

    2006-01-01

    Objective: To evaluate the effect of topical corticosteroid for treatment of moderate or severe dry eye. Methods: Sixty eyes of 30 patients with moderate or severe dry eye, who were not sensitive to artificial tears, were treated with 0.1% fluorometholone eye drops. Subjective symptom and objective tests were used to evaluate the efficacy of treatment before and after application of 0.1% fluorometholone eye drops for 1 week and 1 month. Side effects were also evaluated. Results: After 1 week ...

  17. About the Eye

    Medline Plus

    Full Text Available ... other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health ... Eye Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and ...

  18. [Dry eye syndrome in patients with primary open-angle glaucoma].

    Science.gov (United States)

    Boyko, E V; Simakova, I L; Yakushev, D Yu; Ignat'ev, S A; Alekseev, I B; Mel'nikova, N V; Alyab'ev, M V; Mal'tsev, D S

    2015-01-01

    to determine the frequency and severity of dry eye syndrome (DES) in primary open-angle glaucoma (POAG) patients that are newly diagnosed or already receiving beta blocker instillation therapy. A total of 127 patients (190 eyes) with POAG were divided into two groups. Group 1 included 55 newly diagnosed patients (88 eyes), group 2-72 POAG patients (102 eyes) instilling timolol 0.5% twice daily into the affected eye. The control group included 20 patients (40 eyes) aged 60-88 years (73.6 ± 9.2 years on average) with early age-related cataract. DES was found in 69 POAG patients (79%) who was just starting their topical hypotensive therapy and 85 of those (84%) under treatment (p = 0.39). One should take into account when prescribing ocular hypotensive therapy that newly diagnosed POAG patients usually already suffer from a dry eye. The use of topical beta blockers that contain preservatives exacerbates dry eye signs and symptoms in these patients.

  19. The anisotropy of perceived distance: The eyes story

    Directory of Open Access Journals (Sweden)

    Tošković Oliver

    2011-01-01

    Full Text Available The aim of this study is to determine whether the eye position shift changes perceived distance, that is, whether kinesthetic information from eye muscles affects distance perception. Two experiments were done, in a dark room (reduced-cue situation, with 27 participants, psychology undergraduates. Participants had a task to match distances of three stimuli, on three viewing directions, 0, 30 and 60 deg rees relative to the body. Head and body of participants were fixed, and they changed viewing directions only by moving their eyes. Stimuli were 7cm

  20. Eye gaze tracking based on the shape of pupil image

    Science.gov (United States)

    Wang, Rui; Qiu, Jian; Luo, Kaiqing; Peng, Li; Han, Peng

    2018-01-01

    Eye tracker is an important instrument for research in psychology, widely used in attention, visual perception, reading and other fields of research. Because of its potential function in human-computer interaction, the eye gaze tracking has already been a topic of research in many fields over the last decades. Nowadays, with the development of technology, non-intrusive methods are more and more welcomed. In this paper, we will present a method based on the shape of pupil image to estimate the gaze point of human eyes without any other intrusive devices such as a hat, a pair of glasses and so on. After using the ellipse fitting algorithm to deal with the pupil image we get, we can determine the direction of the fixation by the shape of the pupil.The innovative aspect of this method is to utilize the new idea of the shape of the pupil so that we can avoid much complicated algorithm. The performance proposed is very helpful for the study of eye gaze tracking, which just needs one camera without infrared light to know the changes in the shape of the pupil to determine the direction of the eye gazing, no additional condition is required.