WorldWideScience

Sample records for methods tested included

  1. Evaluation and comparison of multiple test methods, including real-time PCR, for Legionella detection in clinical specimens.

    Directory of Open Access Journals (Sweden)

    Adriana Peci

    2016-08-01

    Full Text Available Legionella is a gram-negative bacterium that can cause Pontiac fever, a mild upper respiratory infection and Legionnaire’s disease, a more severe illness. We aimed to compare the performance of urine antigen, culture and PCR test methods and to determine if sputum is an alternative to the use of more invasive bronchoalveolar lavage (BAL. Data for this study included specimens tested for Legionella at PHOL from January 1, 2010 to April 30, 2014, as part of routine clinical testing. We found sensitivity of UAT compared to culture to be 87%, specificity 94.7%, positive predictive value (PPV 63.8% and negative predictive value (NPV 98.5%. Sensitivity of UAT compared to PCR was 74.7%, specificity 98.3%, PPV 77.7% and NPV 98.1%. Of 146 patients who had a Legionella positive result by PCR, only 66(45.2% also had a positive result by culture. Sensitivity for culture was the same using either sputum or BAL (13.6%; sensitivity for PCR was 10.3% for sputum and 12.8% for BAL. Both sputum and BAL yield similar results despite testing methods (Fisher Exact p-values=1.0, for each test. In summary, all test methods have inherent weaknesses in identifying Legionella; thereforemore than one testing method should be used. Obtaining a single specimen type from patients with pneumonia limits the ability to diagnose Legionella, particularly when urine is the specimen type submitted. Given ease of collection, and similar sensitivity to BAL, clinicians are encouraged to submit sputum in addition to urine when BAL submission is not practical, from patients being tested for Legionella.

  2. Evaluation and Comparison of Multiple Test Methods, Including Real-time PCR, for Legionella Detection in Clinical Specimens

    Science.gov (United States)

    Peci, Adriana; Winter, Anne-Luise; Gubbay, Jonathan B.

    2016-01-01

    Legionella is a Gram-negative bacterium that can cause Pontiac fever, a mild upper respiratory infection and Legionnaire’s disease, a more severe illness. We aimed to compare the performance of urine antigen, culture, and polymerase chain reaction (PCR) test methods and to determine if sputum is an acceptable alternative to the use of more invasive bronchoalveolar lavage (BAL). Data for this study included specimens tested for Legionella at Public Health Ontario Laboratories from 1st January, 2010 to 30th April, 2014, as part of routine clinical testing. We found sensitivity of urinary antigen test (UAT) compared to culture to be 87%, specificity 94.7%, positive predictive value (PPV) 63.8%, and negative predictive value (NPV) 98.5%. Sensitivity of UAT compared to PCR was 74.7%, specificity 98.3%, PPV 77.7%, and NPV 98.1%. Out of 146 patients who had a Legionella-positive result by PCR, only 66 (45.2%) also had a positive result by culture. Sensitivity for culture was the same using either sputum or BAL (13.6%); sensitivity for PCR was 10.3% for sputum and 12.8% for BAL. Both sputum and BAL yield similar results regardless testing methods (Fisher Exact p-values = 1.0, for each test). In summary, all test methods have inherent weaknesses in identifying Legionella; therefore, more than one testing method should be used. Obtaining a single specimen type from patients with pneumonia limits the ability to diagnose Legionella, particularly when urine is the specimen type submitted. Given ease of collection and similar sensitivity to BAL, clinicians are encouraged to submit sputum in addition to urine when BAL submission is not practical from patients being tested for Legionella. PMID:27630979

  3. More Than Just Accuracy: A Novel Method to Incorporate Multiple Test Attributes in Evaluating Diagnostic Tests Including Point of Care Tests.

    Science.gov (United States)

    Thompson, Matthew; Weigl, Bernhard; Fitzpatrick, Annette; Ide, Nicole

    2016-01-01

    Current frameworks for evaluating diagnostic tests are constrained by a focus on diagnostic accuracy, and assume that all aspects of the testing process and test attributes are discrete and equally important. Determining the balance between the benefits and harms associated with new or existing tests has been overlooked. Yet, this is critically important information for stakeholders involved in developing, testing, and implementing tests. This is particularly important for point of care tests (POCTs) where tradeoffs exist between numerous aspects of the testing process and test attributes. We developed a new model that multiple stakeholders (e.g., clinicians, patients, researchers, test developers, industry, regulators, and health care funders) can use to visualize the multiple attributes of tests, the interactions that occur between these attributes, and their impacts on health outcomes. We use multiple examples to illustrate interactions between test attributes (test availability, test experience, and test results) and outcomes, including several POCTs. The model could be used to prioritize research and development efforts, and inform regulatory submissions for new diagnostics. It could potentially provide a way to incorporate the relative weights that various subgroups or clinical settings might place on different test attributes. Our model provides a novel way that multiple stakeholders can use to visualize test attributes, their interactions, and impacts on individual and population outcomes. We anticipate that this will facilitate more informed decision making around diagnostic tests.

  4. Cathodic Delamination Accelerated Life Test Method

    National Research Council Canada - National Science Library

    Ramotowski, Thomas S

    2007-01-01

    A method for conducting an accelerated life test of a polymer coated metallic sample includes placing the sample below the water surface in a test tank containing water and an oxygen containing gas...

  5. Methods for Equating Mental Tests.

    Science.gov (United States)

    1984-11-01

    1983) compared conventional and IRT methods for equating the Test of English as a Foreign Language ( TOEFL ) after chaining. Three conventional and...three IRT equating methods were examined in this study; two sections of TOEFL were each (separately) equated. The IRT methods included the following: (a...group. A separate base form was established for each of the six equating methods. Instead of equating the base-form TOEFL to itself, the last (eighth

  6. Nondestructive testing method

    International Nuclear Information System (INIS)

    Porter, J.F.

    1996-01-01

    Nondestructive testing (NDT) is the use of physical and chemical methods for evaluating material integrity without impairing its intended usefulness or continuing service. Nondestructive tests are used by manufaturer's for the following reasons: 1) to ensure product reliability; 2) to prevent accidents and save human lives; 3) to aid in better product design; 4) to control manufacturing processes; and 5) to maintain a uniform quality level. Nondestructive testing is used extensively on power plants, oil and chemical refineries, offshore oil rigs and pipeline (NDT can even be conducted underwater), welds on tanks, boilers, pressure vessels and heat exchengers. NDT is now being used for testing concrete and composite materials. Because of the criticality of its application, NDT should be performed and the results evaluated by qualified personnel. There are five basic nondestructive examination methods: 1) liquid penetrant testing - method used for detecting surface flaws in materials. This method can be used for metallic and nonmetallic materials, portable and relatively inexpensive. 2) magnetic particle testing - method used to detect surface and subsurface flaws in ferromagnetic materials; 3) radiographic testing - method used to detect internal flaws and significant variation in material composition and thickness; 4) ultrasonic testing - method used to detect internal and external flaws in materials. This method uses ultrasonics to measure thickness of a material or to examine the internal structure for discontinuities. 5) eddy current testing - method used to detect surface and subsurface flaws in conductive materials. Not one nondestructive examination method can find all discontinuities in all of the materials capable of being tested. The most important consideration is for the specifier of the test to be familiar with the test method and its applicability to the type and geometry of the material and the flaws to be detected

  7. Testing and assessment strategies, including alternative and new approaches

    DEFF Research Database (Denmark)

    Meyer, Otto A.

    2003-01-01

    The object of toxicological testing is to predict possible adverse effect in humans when exposed to chemicals whether used as industrial chemicals, pharmaceuticals or pesticides. Animal models are predominantly used in identifying potential hazards of chemicals. The use of laboratory animals raises...... ethical concern. However, irrespective of animal welfare it is an important aspect of the discipline of toxicology that the primary object is human health. The ideal testing and assessment strategy is simple to use all the available test methods and preferably more in laboratory animal species from which...... uses and of the absence of health problems involved with their use. Thus, the regulatory toxicology is a cocktail of science and pragmatism added a crucial concern for animal welfare. Test methods are most often used in a testing sequence as bricks in a testing strategy. The main key driving forces...

  8. Methods for testing transport models

    International Nuclear Information System (INIS)

    Singer, C.; Cox, D.

    1993-01-01

    This report documents progress to date under a three-year contract for developing ''Methods for Testing Transport Models.'' The work described includes (1) choice of best methods for producing ''code emulators'' for analysis of very large global energy confinement databases, (2) recent applications of stratified regressions for treating individual measurement errors as well as calibration/modeling errors randomly distributed across various tokamaks, (3) Bayesian methods for utilizing prior information due to previous empirical and/or theoretical analyses, (4) extension of code emulator methodology to profile data, (5) application of nonlinear least squares estimators to simulation of profile data, (6) development of more sophisticated statistical methods for handling profile data, (7) acquisition of a much larger experimental database, and (8) extensive exploratory simulation work on a large variety of discharges using recently improved models for transport theories and boundary conditions. From all of this work, it has been possible to define a complete methodology for testing new sets of reference transport models against much larger multi-institutional databases

  9. Comparison of high efficiency particulate filter testing methods

    International Nuclear Information System (INIS)

    1985-01-01

    High Efficiency Particulate Air (HEPA) filters are used for the removal of submicron size particulates from air streams. In nuclear industry they are used as an important engineering safeguard to prevent the release of air borne radioactive particulates to the environment. HEPA filters used in the nuclear industry should therefore be manufactured and operated under strict quality control. There are three levels of testing HEPA filters: i) testing of the filter media; ii) testing of the assembled filter including filter media and filter housing; and iii) on site testing of the complete filter installation before putting into operation and later for the purpose of periodic control. A co-ordinated research programme on particulate filter testing methods was taken up by the Agency and contracts were awarded to the Member Countries, Belgium, German Democratic Republic, India and Hungary. The investigations carried out by the participants of the present co-ordinated research programme include the results of the nowadays most frequently used HEPA filter testing methods both for filter medium test, rig test and in-situ test purposes. Most of the experiments were carried out at ambient temperature and humidity, but indications were given to extend the investigations to elevated temperature and humidity in the future for the purpose of testing the performance of HEPA filter under severe conditions. A major conclusion of the co-ordinated research programme was that it was not possible to recommend one method as a reference method for in situ testing of high efficiency particulate air filters. Most of the present conventional methods are adequate for current requirements. The reasons why no method is to be recommended were multiple, ranging from economical aspects, through incompatibility of materials to national regulations

  10. Integrated Data Collection Analysis (IDCA) Program - SSST Testing Methods

    Energy Technology Data Exchange (ETDEWEB)

    Sandstrom, Mary M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Brown, Geoffrey W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Preston, Daniel N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pollard, Colin J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Warner, Kirstin F. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Remmers, Daniel L. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Sorensen, Daniel N. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Whinnery, LeRoy L. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Phillips, Jason J. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Shelley, Timothy J. [Bureau of Alcohol, Tobacco and Firearms (ATF), Huntsville, AL (United States); Reyes, Jose A. [Applied Research Associates, Tyndall AFB, FL (United States); Hsu, Peter C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Reynolds, John G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-03-25

    The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the methods used for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis during the IDCA program. These methods changed throughout the Proficiency Test and the reasons for these changes are documented in this report. The most significant modifications in standard testing methods are: 1) including one specified sandpaper in impact testing among all the participants, 2) diversifying liquid test methods for selected participants, and 3) including sealed sample holders for thermal testing by at least one participant. This effort, funded by the Department of Homeland Security (DHS), is putting the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study will suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. The testing performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent.

  11. Review of Artificial Abrasion Test Methods for PV Module Technology

    Energy Technology Data Exchange (ETDEWEB)

    Miller, David C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Muller, Matt T. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Simpson, Lin J. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-08-01

    This review is intended to identify the method or methods--and the basic details of those methods--that might be used to develop an artificial abrasion test. Methods used in the PV literature were compared with their closest implementation in existing standards. Also, meetings of the International PV Quality Assurance Task Force Task Group 12-3 (TG12-3, which is concerned with coated glass) were used to identify established test methods. Feedback from the group, which included many of the authors from the PV literature, included insights not explored within the literature itself. The combined experience and examples from the literature are intended to provide an assessment of the present industry practices and an informed path forward. Recommendations toward artificial abrasion test methods are then identified based on the experiences in the literature and feedback from the PV community. The review here is strictly focused on abrasion. Assessment methods, including optical performance (e.g., transmittance or reflectance), surface energy, and verification of chemical composition were not examined. Methods of artificially soiling PV modules or other specimens were not examined. The weathering of artificial or naturally soiled specimens (which may ultimately include combined temperature and humidity, thermal cycling and ultraviolet light) were also not examined. A sense of the purpose or application of an abrasion test method within the PV industry should, however, be evident from the literature.

  12. Standard Test Method for Hot Spot Protection Testing of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method provides a procedure to determine the ability of a photovoltaic (PV) module to endure the long-term effects of periodic “hot spot” heating associated with common fault conditions such as severely cracked or mismatched cells, single-point open circuit failures (for example, interconnect failures), partial (or non-uniform) shadowing or soiling. Such effects typically include solder melting or deterioration of the encapsulation, but in severe cases could progress to combustion of the PV module and surrounding materials. 1.2 There are two ways that cells can cause a hot spot problem; either by having a high resistance so that there is a large resistance in the circuit, or by having a low resistance area (shunt) such that there is a high-current flow in a localized region. This test method selects cells of both types to be stressed. 1.3 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method....

  13. Standard test method for tension testing of structural alloys in liquid helium

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method describes procedures for the tension testing of structural alloys in liquid helium. The format is similar to that of other ASTM tension test standards, but the contents include modifications for cryogenic testing which requires special apparatus, smaller specimens, and concern for serrated yielding, adiabatic heating, and strain-rate effects. 1.2 To conduct a tension test by this standard, the specimen in a cryostat is fully submerged in normal liquid helium (He I) and tested using crosshead displacement control at a nominal strain rate of 10−3 s−1 or less. Tests using force control or high strain rates are not considered. 1.3 This standard specifies methods for the measurement of yield strength, tensile strength, elongation, and reduction of area. The determination of the elastic modulus is treated in Test Method E 111. Note 1—The boiling point of normal liquid helium (He I) at sea level is 4.2 K (−269°C or −452.1°F or 7.6°R). It decreases with geographic elevation and is...

  14. Standard test method for creep-fatigue testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of mechanical properties pertaining to creep-fatigue deformation or crack formation in nominally homogeneous materials, or both by the use of test specimens subjected to uniaxial forces under isothermal conditions. It concerns fatigue testing at strain rates or with cycles involving sufficiently long hold times to be responsible for the cyclic deformation response and cycles to crack formation to be affected by creep (and oxidation). It is intended as a test method for fatigue testing performed in support of such activities as materials research and development, mechanical design, process and quality control, product performance, and failure analysis. The cyclic conditions responsible for creep-fatigue deformation and cracking vary with material and with temperature for a given material. 1.2 The use of this test method is limited to specimens and does not cover testing of full-scale components, structures, or consumer products. 1.3 This test method is primarily ...

  15. Standard Test Method for Wet Insulation Integrity Testing of Photovoltaic Arrays

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers a procedure to determine the insulation resistance of a photovoltaic (PV) array (or its component strings), that is, the electrical resistance between the array's internal electrical components and is exposed, electrically conductive, non-current carrying parts and surfaces of the array. 1.2 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  16. Multipath interference test method for distributed amplifiers

    Science.gov (United States)

    Okada, Takahiro; Aida, Kazuo

    2005-12-01

    A method for testing distributed amplifiers is presented; the multipath interference (MPI) is detected as a beat spectrum between the multipath signal and the direct signal using a binary frequency shifted keying (FSK) test signal. The lightwave source is composed of a DFB-LD that is directly modulated by a pulse stream passing through an equalizer, and emits the FSK signal of the frequency deviation of about 430MHz at repetition rate of 80-100 kHz. The receiver consists of a photo-diode and an electrical spectrum analyzer (ESA). The base-band power spectrum peak appeared at the frequency of the FSK frequency deviation can be converted to amount of MPI using a calibration chart. The test method has improved the minimum detectable MPI as low as -70 dB, compared to that of -50 dB of the conventional test method. The detailed design and performance of the proposed method are discussed, including the MPI simulator for calibration procedure, computer simulations for evaluating the error caused by the FSK repetition rate and the fiber length under test and experiments on singlemode fibers and distributed Raman amplifier.

  17. Evaluation of snubber functional test methods: Tier 1

    International Nuclear Information System (INIS)

    Brown, D.P.

    1993-07-01

    The objective of the research is to establish technical bases in support of efforts on the part of the Snubber Utility Group (SNUG) and the Subsection ISTD Working Group of the ASME O ampersand M Code in developing guidelines and methodologies for snubber functional testing to ensure that snubbers are tested in a manner that ensures reliable and meaningful test results. The methodology used in this research includes both a review of available industry information as well as the testing of different snubber models using various test machines. Information is provided pertaining to current industry practices in regard to snubber testing including recommended test procedures, technical description of various test machines, and the number and types of snubbers used in the nuclear power industry. A review of previous test methodology research conducted by the Snubber Utility Group is also included. The effects of variations in controllable test parameters on snubber test results are discussed. Also included are the results of confirmatory tests in which various snubber models were tested using various test machines. Recommendations are provided for standard test methods to be included in Subsection ISTD of the ASME O ampersand M Code [4]. General information and recommendations are provided that may be used by utility personnel in specifying snubber test equipment that is most suited for plant-specific needs as well as information that may be effectively used in the review and interpretation of test results

  18. Standard test method for electrochemical critical pitting temperature testing of stainless steels

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method covers a procedure for the evaluation of the resistance of stainless steel and related alloys to pitting corrosion based on the concept of the determination of a potential independent critical pitting temperature (CPT). 1.2 This test methods applies to wrought and cast products including but not restricted to plate, sheet, tubing, bar, forgings, and welds, (see Note 1). Note 1—Examples of CPT measurements on sheet, plate, tubing, and welded specimens for various stainless steels can be found in Ref (1). See the research reports (Section 14). 1.3 The standard parameters recommended in this test method are suitable for characterizing the CPT of austenitic stainless steels and other related alloys with a corrosion resistance ranging from that corresponding to solution annealed UNS S31600 (Type 316 stainless steel) to solution annealed UNS S31254 (6 % Mo stainless steel). 1.4 This test method may be extended to stainless steels and other alloys related to stainless steel that have a CPT...

  19. Hydraulic testing of Type Q septifoils including modifications

    International Nuclear Information System (INIS)

    Steimke, J.L.; Fowley, M.D.; Guerrero, H.N.

    1992-09-01

    On May 25, 1992 a leak of moderator was detected as K Reactor was approaching initial criticality. The partial length control rods were being withdrawn when the leak detectors in the Process Room alarmed. The apparent location of the moderator leak was the top of the guide tubes which are positioned over the new Type Q septifoils. The reactor was shut down immediately. In response, a testing program was begun at the Heat Transfer Laboratory (HTL). The goals of the program were to determine the cause of the septifoil leak and to test methods for preventing future leaks. These tests are described in this report

  20. Test equating, scaling, and linking methods and practices

    CERN Document Server

    Kolen, Michael J

    2014-01-01

    This book provides an introduction to test equating, scaling, and linking, including those concepts and practical issues that are critical for developers and all other testing professionals.  In addition to statistical procedures, successful equating, scaling, and linking involves many aspects of testing, including procedures to develop tests, to administer and score tests, and to interpret scores earned on tests. Test equating methods are used with many standardized tests in education and psychology to ensure that scores from multiple test forms can be used interchangeably.  Test scaling is the process of developing score scales that are used when scores on standardized tests are reported. In test linking, scores from two or more tests are related to one another. Linking has received much recent attention, due largely to investigations of linking similarly named tests from different test publishers or tests constructed for different purposes. In recent years, researchers from the education, psychology, and...

  1. Comments on Thermal Physical Properties Testing Methods of Phase Change Materials

    Directory of Open Access Journals (Sweden)

    Jingchao Xie

    2013-01-01

    Full Text Available There is no standard testing method of the thermal physical properties of phase change materials (PCM. This paper has shown advancements in this field. Developments and achievements in thermal physical properties testing methods of PCM were commented, including differential scanning calorimetry, T-history measurement, the water bath method, and differential thermal analysis. Testing principles, advantages and disadvantages, and important points for attention of each method were discussed. A foundation for standardized testing methods for PCM was made.

  2. Reliability Verification of DBE Environment Simulation Test Facility by using Statistics Method

    International Nuclear Information System (INIS)

    Jang, Kyung Nam; Kim, Jong Soeg; Jeong, Sun Chul; Kyung Heum

    2011-01-01

    In the nuclear power plant, all the safety-related equipment including cables under the harsh environment should perform the equipment qualification (EQ) according to the IEEE std 323. There are three types of qualification methods including type testing, operating experience and analysis. In order to environmentally qualify the safety-related equipment using type testing method, not analysis or operation experience method, the representative sample of equipment, including interfaces, should be subjected to a series of tests. Among these tests, Design Basis Events (DBE) environment simulating test is the most important test. DBE simulation test is performed in DBE simulation test chamber according to the postulated DBE conditions including specified high-energy line break (HELB), loss of coolant accident (LOCA), main steam line break (MSLB) and etc, after thermal and radiation aging. Because most DBE conditions have 100% humidity condition, in order to trace temperature and pressure of DBE condition, high temperature steam should be used. During DBE simulation test, if high temperature steam under high pressure inject to the DBE test chamber, the temperature and pressure in test chamber rapidly increase over the target temperature. Therefore, the temperature and pressure in test chamber continue fluctuating during the DBE simulation test to meet target temperature and pressure. We should ensure fairness and accuracy of test result by confirming the performance of DBE environment simulation test facility. In this paper, in order to verify reliability of DBE environment simulation test facility, statistics method is used

  3. Nondestructive testing methods for 55-gallon, waste storage drums

    International Nuclear Information System (INIS)

    Ferris, R.H.; Hildebrand, B.P.; Hockey, R.L.; Riechers, D.M.; Spanner, J.C.; Duncan, D.R.

    1993-06-01

    The Westinghouse Hanford Company (WHC) authorized Pacific Northwest Laboratory (PNL) to conduct a feasibility study to identify promising nondestructive testing (NDT) methods for detecting general and localized (both pitting and pinhole) corrosion in the 55-gal drums that are used to store solid waste materials at the Hanford Site. This document presents results obtained during a literature survey, identifies the relevant reference materials that were reviewed, provides a technical description of the methods that were evaluated, describes the laboratory tests that were conducted and their results, identifies the most promising candidate methods along with the rationale for these selections, and includes a work plan for recommended follow-on activities. This report contains a brief overview and technical description for each of the following NDT methods: magnetic testing techniques; eddy current testing; shearography; ultrasonic testing; radiographic computed tomography; thermography; and leak testing with acoustic detection

  4. Standard test method for galling resistance of material couples

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers a laboratory test that ranks the galling resistance of material couples using a quantitative measure. Bare metals, alloys, nonmetallic materials, coatings, and surface modified materials may be evaluated by this test method. 1.2 This test method is not designed for evaluating the galling resistance of material couples sliding under lubricated conditions, because galling usually will not occur under lubricated sliding conditions using this test method. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. Including test errors in evaluating surveillance test intervals

    International Nuclear Information System (INIS)

    Kim, I.S.; Samanta, P.K.; Martorell, S.; Vesely, W.E.

    1991-01-01

    Technical Specifications require surveillance testing to assure that the standby systems important to safety will start and perform their intended functions in the event of plant abnormality. However, as evidenced by operating experience, the surveillance tests may be adversely impact safety because of their undesirable side effects, such as initiation of plant transients during testing or wearing-out of safety systems due to testing. This paper first defines the concerns, i.e., the potential adverse effects of surveillance testing, from a risk perspective. Then, we present a methodology to evaluate the risk impact of those adverse effects, focusing on two important kinds of adverse impacts of surveillance testing: (1) risk impact of test-caused trips and (2) risk impact of test-caused equipment wear. The quantitative risk methodology is demonstrated with several surveillance tests conducted at boiling water reactors, such as the tests of the main steam isolation valves, the turbine overspeed protection system, and the emergency diesel generators. We present the results of the risk-effectiveness evaluation of surveillance test intervals, which compares the adverse risk impact with the beneficial risk impact of testing from potential failure detection, along with insights from sensitivity studies

  6. Antifungal susceptibility testing method for resource constrained laboratories

    Directory of Open Access Journals (Sweden)

    Khan S

    2006-01-01

    Full Text Available Purpose: In resource-constrained laboratories of developing countries determination of antifungal susceptibility testing by NCCLS/CLSI method is not always feasible. We describe herein a simple yet comparable method for antifungal susceptibility testing. Methods: Reference MICs of 72 fungal isolates including two quality control strains were determined by NCCLS/CLSI methods against fluconazole, itraconazole, voriconazole, amphotericin B and cancidas. Dermatophytes were also tested against terbinafine. Subsequently, on selection of optimum conditions, MIC was determined for all the fungal isolates by semisolid antifungal agar susceptibility method in Brain heart infusion broth supplemented with 0.5% agar (BHIA without oil overlay and results were compared with those obtained by reference NCCLS/CLSI methods. Results: Comparable results were obtained by NCCLS/CLSI and semisolid agar susceptibility (SAAS methods against quality control strains. MICs for 72 isolates did not differ by more than one dilution for all drugs by SAAS. Conclusions: SAAS using BHIA without oil overlay provides a simple and reproducible method for obtaining MICs against yeast, filamentous fungi and dermatophytes in resource-constrained laboratories.

  7. Studies on Hepa filter test methods

    International Nuclear Information System (INIS)

    Lee, S.H.; Jon, K.S.; Park, W.J.; Ryoo, R.

    1981-01-01

    The purpose of this study is to compare testing methods of the HEPA filter adopted in other countries with each other, and to design and construct a test duct system to establish testing methods. The American D.O.P. test method, the British NaCl test method and several other independently developed methods are compared. It is considered that the D.O.P. method is most suitable for in-plant and leak tests

  8. Standardized waste form test methods

    International Nuclear Information System (INIS)

    Slate, S.C.

    1984-01-01

    The Materials Characterization Center (MCC) is developing standard tests to characterize nuclear waste forms. Development of the first thirteen tests was originally initiated to provide data to compare different high-level waste (HLW) forms and to characterize their basic performance. The current status of the first thirteen MCC tests and some sample test results are presented: the radiation stability tests (MCC-6 and 12) and the tensile-strength test (MCC-11) are approved; the static leach tests (MCC-1, 2, and 3) are being reviewed for full approval; the thermal stability (MCC-7) and microstructure evaluation (MCC-13) methods are being considered for the first time; and the flowing leach test methods (MCC-4 and 5), the gas generation methods (MCC-8 and 9), and the brittle fracture method (MCC-10) are indefinitely delayed. Sample static leach test data on the ARM-1 approved reference material are presented. Established tests and proposed new tests will be used to meet new testing needs. For waste form production, tests on stability and composition measurement are needed to provide data to ensure waste form quality. In transporation, data are needed to evaluate the effects of accidents on canisterized waste forms. The new MCC-15 accident test method and some data are presented. Compliance testing needs required by the recent draft repository waste acceptance specifications are described. These specifications will control waste form contents, processing, and performance

  9. Standardized waste form test methods

    International Nuclear Information System (INIS)

    Slate, S.C.

    1984-11-01

    The Materials Characterization Center (MCC) is developing standard tests to characterize nuclear waste forms. Development of the first thirteen tests was originally initiated to provide data to compare different high-level waste (HLW) forms and to characterize their basic performance. The current status of the first thirteen MCC tests and some sample test results is presented: The radiation stability tests (MCC-6 and 12) and the tensile-strength test (MCC-11) are approved; the static leach tests (MCC-1, 2, and 3) are being reviewed for full approval; the thermal stability (MCC-7) and microstructure evaluation (MCC-13) methods are being considered for the first time; and the flowing leach tests methods (MCC-4 and 5), the gas generation methods (MCC-8 and 9), and the brittle fracture method (MCC-10) are indefinitely delayed. Sample static leach test data on the ARM-1 approved reference material are presented. Established tests and proposed new tests will be used to meet new testing needs. For waste form production, tests on stability and composition measurement are needed to provide data to ensure waste form quality. In transportation, data are needed to evaluate the effects of accidents on canisterized waste forms. The new MCC-15 accident test method and some data are presented. Compliance testing needs required by the recent draft repository waste acceptance specifications are described. These specifications will control waste form contents, processing, and performance. 2 references, 2 figures

  10. Standard test method for drop-weight tear tests of ferritic steels

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This test method covers drop-weight tear tests (DWTT) on ferritic steels with thicknesses between 3.18 and 19.1 mm. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  11. Biostatistics with emphasis on life table survival rate calculations (including Kaplan Meier) and the logrank test

    International Nuclear Information System (INIS)

    Mould, Richard F.

    1995-01-01

    Purpose/Objective: To explain some of the most useful statistical calculation procedures which are relevant to radiation oncologists and to provide insights on what tests and procedures should be used in various situations such as when survival rates and their associated standard errors have to be determined. To describe some of the problems and pitfalls in clinical trial designs which have to be overcome if a trial is to have the possibility of reaching a successful conclusion. To review methods of computing criteria to quantitatively describe criteria of success (eg. quality of life, long-term survival, cure) of radiation oncology and to suggest possible future statistical improvements in this area. Chi-Squared Test: The chi-squared test is probably the most useful of the tests of statistical significance for the radiation oncologist. Applications will be described, including goodness of fit tests and 2x2 contingency tables which are the simplest of the generalized nxm contingency tables. Degrees of Freedom and P<0.05 for Significance Testing: An Introduction will be given to the meaning of P<0.05 in relation to significance testing and the use of tables of critical values of a test statistic (eg. chi-squared) which are given as a function of degrees of freedom and P-values. Survival Rate Calculations for Grouped and Ungrouped Data: The life-table method (sometimes termed the actuarial method) will be explained for both grouped data (eg. survival times grouped in annual intervals for patients who have died and for those who are still alive or lost to follow-up) and for ungrouped data (when individual survival times are used). The method for ungrouped data is variously termed the Kaplan-Meier or Product Limit method. Logrank Test: This is the most useful test for comparison of the survival experience of two groups of patients and its use will be explained. In part the computation is similar to that for the Kaplan-Meier/Product Limit method

  12. Biostatistics with emphasis on life table survival rate calculations (including Kaplan Meier) and the logrank test

    Energy Technology Data Exchange (ETDEWEB)

    Mould, Richard F

    1995-07-01

    Purpose/Objective: To explain some of the most useful statistical calculation procedures which are relevant to radiation oncologists and to provide insights on what tests and procedures should be used in various situations such as when survival rates and their associated standard errors have to be determined. To describe some of the problems and pitfalls in clinical trial designs which have to be overcome if a trial is to have the possibility of reaching a successful conclusion. To review methods of computing criteria to quantitatively describe criteria of success (eg. quality of life, long-term survival, cure) of radiation oncology and to suggest possible future statistical improvements in this area. Chi-Squared Test: The chi-squared test is probably the most useful of the tests of statistical significance for the radiation oncologist. Applications will be described, including goodness of fit tests and 2x2 contingency tables which are the simplest of the generalized nxm contingency tables. Degrees of Freedom and P<0.05 for Significance Testing: An Introduction will be given to the meaning of P<0.05 in relation to significance testing and the use of tables of critical values of a test statistic (eg. chi-squared) which are given as a function of degrees of freedom and P-values. Survival Rate Calculations for Grouped and Ungrouped Data: The life-table method (sometimes termed the actuarial method) will be explained for both grouped data (eg. survival times grouped in annual intervals for patients who have died and for those who are still alive or lost to follow-up) and for ungrouped data (when individual survival times are used). The method for ungrouped data is variously termed the Kaplan-Meier or Product Limit method. Logrank Test: This is the most useful test for comparison of the survival experience of two groups of patients and its use will be explained. In part the computation is similar to that for the Kaplan-Meier/Product Limit method.

  13. Semiconductor testing method

    International Nuclear Information System (INIS)

    Brown, Stephen.

    1992-01-01

    In a method of avoiding use of nuclear radiation, eg gamma rays, X-rays, electron beams, for testing semiconductor components for resistance to hard radiation, which hard radiation causes data corruption in some memory devices and 'latch-up' in others, similar fault effects can be achieved using a xenon or other 'light' flash gun even though the penetration of light is significantly less than that of gamma rays. The method involves treating a device with gamma radiation, measuring a particular fault current at the onset of a fault event, repeating the test with light to confirm the occurrence of the fault event at the same measured fault current, and using the fault current value as a reference for future tests using light on similar devices. (author)

  14. Comparative study of in-situ filter test methods

    International Nuclear Information System (INIS)

    Marshall, M.; Stevens, D.C.

    1981-01-01

    Available methods of testing high efficiency particulate aerosol (HEPA) filters in-situ have been reviewed. In order to understand the relationship between the results produced by different methods a selection has been compared. Various pieces of equipment for generating and detecting aerosols have been tested and their suitability assessed. Condensation-nuclei, DOP (di-octyl phthalate) and sodium-flame in-situ filter test methods have been studied, using the 500 cfm (9000 m 3 /h) filter test rig at Harwell and in the field. Both the sodium-flame and DOP methods measure the penetration through leaks and filter material. However the measured penetration through filtered leaks depends on the aerosol size distribution and the detection method. Condensation-nuclei test methods can only be used to measure unfiltered leaks since condensation nuclei have a very low penetration through filtered leaks. A combination of methods would enable filtered and unfiltered leaks to be measured. A condensation-nucleus counter using n-butyl alcohol as the working fluid has the advantage of being able to detect any particle up to 1 μm in diameter, including DOP, and so could be used for this purpose. A single-particle counter has not been satisfactory because of interference from particles leaking into systems under extract, particularly downstream of filters, and because the concentration of the input aerosol has to be severely limited. The sodium-flame method requires a skilled operator and may cause safety and corrosion problems. The DOP method using a total light scattering detector has so far been the most satisfactory. It is fairly easy to use, measures reasonably low values of penetration and gives rapid results. DOP has had no adverse effect on HEPA filters over a long series of tests

  15. Standard test method for damage to contacting solid surfaces under fretting conditions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the studying or ranking the susceptibility of candidate materials to fretting corrosion or fretting wear for the purposes of material selection for applications where fretting corrosion or fretting wear can limit serviceability. 1.2 This test method uses a tribological bench test apparatus with a mechanism or device that will produce the necessary relative motion between a contacting hemispherical rider and a flat counterface. The rider is pressed against the flat counterface with a loading mass. The test method is intended for use in room temperature air, but future editions could include fretting in the presence of lubricants or other environments. 1.3 The purpose of this test method is to rub two solid surfaces together under controlled fretting conditions and to quantify the damage to both surfaces in units of volume loss for the test method. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5...

  16. Environmental site assessments should include radon gas testing

    International Nuclear Information System (INIS)

    Nardi, M.A.

    1991-01-01

    There are two emerging influences that will require radon gas testing as part of many property transfers and most site assessments. These requirements come from lending regulators and state legislatures. Fannie Mae and others have developed environmental investigation guidelines for the purchase of environmentally contaminated real estate. These guidelines include radon gas testing for many properties. Several states have enacted laws that require environmental disclosure forms be prepared to ensure that the parties involved in certain real estate transactions are aware of the environmental liabilities that may come with the transfer of property. Indiana has recently enacted legislation that would require the disclosure of the presence of radon gas on many commercial real estate transactions. With more lenders and state governments likely to follow this trend, radon gas testing should be performed during all property transfers and site assessment to protect the parties involved from any legal liabilities

  17. Test report for cesium powder and pellets inner container decontamination method determination test

    International Nuclear Information System (INIS)

    Kelly, D.L.

    1998-01-01

    This report documents the decontamination method determination testing that was performed on three cesium powder and pellets inner container test specimens The test specimens were provided by B and W Hanford Company (BVMC). The tests were conducted by the Numatec Hanford Company (NHC), in the 305 Building. Photographic evidence was also provided by NHC. The Test Plan and Test Report were provided by Waste Management Federal Services, Inc., Northwest Operations. Witnesses to testing included a test engineer, a BC project engineer, and a BC Quality Assurance (QA) representative. The Test Plan was modified with the mutual decision of the test engineer, the BWHC project engineer, and the BVMC QA representative. The results of this decision were written in red (permanent type) ink on the official copy of the test procedure, Due to the extent of the changes, a summary of the test results are provided in Section 3.0 of this Test Report. In addition, a copy of the official copy field documentation obtained during testing is included in Appendix A. The original Test Plan (HNF-2945) will be revised to indicate that extensive changes were required in the field during testing, however, the test documentation will stand as is (i.e., it will not be retyped, text shaded, etc.) due to the inclusion of the test parameters and results into this Test Report

  18. Methodology for developing new test methods

    Directory of Open Access Journals (Sweden)

    A. I. Korobko

    2017-06-01

    Full Text Available The paper describes the methodology for developing new test methods and forming solutions for the development of new test methods. The basis of the methodology for developing new test methods is the individual elements of the system and process approaches. They contribute to the development of an effective research strategy for the object, the study of interrelations, the synthesis of an adequate model of the test method. The effectiveness of the developed test method is determined by the correct choice of the set of concepts, their interrelations and mutual influence. This allows you to solve the tasks assigned to achieve the goal. The methodology is based on the use of fuzzy cognitive maps. The question of the choice of the method on the basis of which the model for the formation of solutions is based is considered. The methodology provides for recording a model for a new test method in the form of a finite set of objects. These objects are significant for the test method characteristics. Then a causal relationship is established between the objects. Further, the values of fitness indicators and the observability of the method and metrological tolerance for the indicator are established. The work is aimed at the overall goal of ensuring the quality of tests by improving the methodology for developing the test method.

  19. Rheological Method for Alpha Test Evaluation of Developing Superplasticizers’ Performance: Channel Flow Test

    Directory of Open Access Journals (Sweden)

    Jae Hong Kim

    2017-01-01

    Full Text Available Advance in high-range water-reducing admixture revolutionizes the workability and constructability of conventional vibrated concrete as well as self-consolidating concrete. Its need from construction fields has increased, and consequently a variety of new-type polycarboxylates, base polymers for the admixture, are being formulated in these days. Synthesizing new polymers needs a quick, but reliable, test to evaluate its performance on concrete. The test is also asked for selecting the best applicable brand of them before a test concrete will be mixed. This paper proposes a “channel flow test” and its usage for the purpose. The proposed procedure for the test includes the mix proportion of a test mortar, the test method, and rheological interpretation of the test results.

  20. Tracers and Tracer Testing: Design, Implementation, Tracer Selection, and Interpretation Methods

    Energy Technology Data Exchange (ETDEWEB)

    G. Michael Shook; Shannon L.; Allan Wylie

    2004-01-01

    Conducting a successful tracer test requires adhering to a set of steps. The steps include identifying appropriate and achievable test goals, identifying tracers with the appropriate properties, and implementing the test as designed. When these steps are taken correctly, a host of tracer test analysis methods are available to the practitioner. This report discusses the individual steps required for a successful tracer test and presents methods for analysis. The report is an overview of tracer technology; the Suggested Reading section offers references to the specifics of test design and interpretation.

  1. Standard test methods for elevated temperature tension tests of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods cover procedure and equipment for the determination of tensile strength, yield strength, elongation, and reduction of area of metallic materials at elevated temperatures. 1.2 Determination of modulus of elasticity and proportional limit are not included. 1.3 Tension tests under conditions of rapid heating or rapid strain rates are not included. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. Study of test methods for radionuclide migration in aerated zone

    International Nuclear Information System (INIS)

    Li Shushen; Guo Zede; Wang Zhiming

    1993-01-01

    Aerated zone is an important natural barrier against transport of radionuclides released from disposal facilities of LLRW. This paper introduces study methods for radionuclide migration in aerated zone, including determination of water movement, laboratory simulation test, and field tracing test. For one purpose, results obtained with different methods are compared. These methods have been used in a five-year cooperative research project between CIRP and JAERI for an establishment of methodology for safety assessment on shallow land disposal of LLRW

  3. Property transfer assessments should include radon gas testing

    International Nuclear Information System (INIS)

    Nardi, M.A.

    1992-01-01

    There are two emerging influences that will require radon gas testing as part of many property transfers and most environmental assessments. These requirements come from lending regulators and state legislatures and affect single family, multifamily, and commercial properties. Fannie Mae and others have developed environmental investigation guidelines for protection from long term legal liabilities in the purchase of environmentally contaminated real estate. These guidelines include radon gas testing for many properties. Several states have enacted laws that require environmental disclosure forms be prepared to ensure that the parties involved in certain real estate transactions are aware of the environmental liabilities that may come with the transfer of property. Indiana has recently enacted legislation that would require the disclosure of the presence of radon gas on many commercial real estate transactions. With more banks and state governments following this trend, radon gas testing should be performed during all property transfers and environmental assessments to protect the parties involved from any long term legal liabilities

  4. Methods of producing adsorption media including a metal oxide

    Science.gov (United States)

    Mann, Nicholas R; Tranter, Troy J

    2014-03-04

    Methods of producing a metal oxide are disclosed. The method comprises dissolving a metal salt in a reaction solvent to form a metal salt/reaction solvent solution. The metal salt is converted to a metal oxide and a caustic solution is added to the metal oxide/reaction solvent solution to adjust the pH of the metal oxide/reaction solvent solution to less than approximately 7.0. The metal oxide is precipitated and recovered. A method of producing adsorption media including the metal oxide is also disclosed, as is a precursor of an active component including particles of a metal oxide.

  5. A Study on the Improvement of Safety Testing Standards and Methods for Mammography

    International Nuclear Information System (INIS)

    Choi, Seon Hyeong; Jung, Ah Young; Yong, Hwan Seok; Kim, Do Wan; Jang, Gi Won; Cha, Sang Hoon; Jo, Sang Won; Park, Ji Koon

    2012-01-01

    To establish the improved national safety testing standards and methods for mammography. We investigated and compared the current status of mammographic equipment installation with the national and international safety and quality control programs and methods. We established and verified the draft for safety testing standards and methods. We propose that the investigations of the conductor system, hardware leakage radiation profile, illumination intensity test, comparison between X-ray and light photon exposure, X-ray dose exposure on the chest wall, compression equipment size, timing equipment, and the average effective radiation dose, should all be maintained as they are in the present state without any changes. However, the exposure radiation dose reproducibility, kVp and mAs, and the half value layer tests should be reconsidered and revised. Moreover, compression pressure and autonomic exposure control system (AEC) tests should be included as new criteria. Other parameter controls included in the phantom image analysis which overlap with total quality assurance should be excluded. We recommend that AEC and compression pressure tests should be included as new criteria and the methods for the exposure radiation dose reproducibility, kVp, and mAs, and half value layer tests should be reconsidered and revised.

  6. Standard Test Method for Contamination Outgassing Characteristics of Spacecraft Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers a technique for generating data to characterize the kinetics of the release of outgassing products from materials. This technique will determine both the total mass flux evolved by a material when exposed to a vacuum environment and the deposition of this flux on surfaces held at various specified temperatures. 1.2 This test method describes the test apparatus and related operating procedures for evaluating the total mass flux that is evolved from a material being subjected to temperatures that are between 298 and 398 K. Pressures external to the sample effusion cell are less than 7 × 10−3 Pa (5 × 10−5 torr). Deposition rates are measured during material outgassing tests. A test procedure for collecting data and a test method for processing and presenting the collected data are included. 1.3 This test method can be used to produce the data necessary to support mathematical models used for the prediction of molecular contaminant generation, migration, and deposition. 1.4 Al...

  7. Standard test methods for bend testing of material for ductility

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods cover bend testing for ductility of materials. Included in the procedures are four conditions of constraint on the bent portion of the specimen; a guided-bend test using a mandrel or plunger of defined dimensions to force the mid-length of the specimen between two supports separated by a defined space; a semi-guided bend test in which the specimen is bent, while in contact with a mandrel, through a specified angle or to a specified inside radius (r) of curvature, measured while under the bending force; a free-bend test in which the ends of the specimen are brought toward each other, but in which no transverse force is applied to the bend itself and there is no contact of the concave inside surface of the bend with other material; a bend and flatten test, in which a transverse force is applied to the bend such that the legs make contact with each other over the length of the specimen. 1.2 After bending, the convex surface of the bend is examined for evidence of a crack or surface irregu...

  8. 49 CFR 383.133 - Testing methods.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Testing methods. 383.133 Section 383.133... STANDARDS; REQUIREMENTS AND PENALTIES Tests § 383.133 Testing methods. (a) All tests shall be constructed in... must be at least as stringent as the Federal standards. (c) States shall determine specific methods for...

  9. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  10. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  11. Microfluidic devices and methods including porous polymer monoliths

    Science.gov (United States)

    Hatch, Anson V; Sommer, Gregory J; Singh, Anup K; Wang, Ying-Chih; Abhyankar, Vinay V

    2014-04-22

    Microfluidic devices and methods including porous polymer monoliths are described. Polymerization techniques may be used to generate porous polymer monoliths having pores defined by a liquid component of a fluid mixture. The fluid mixture may contain iniferters and the resulting porous polymer monolith may include surfaces terminated with iniferter species. Capture molecules may then be grafted to the monolith pores.

  12. Standard Test Method for Testing Nonmetallic Seal Materials by Immersion in a Simulated Geothermal Test Fluid

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This test method covers a procedure for a laboratory test for performing an initial evaluation (screening) of nonmetallic seal materials by immersion in a simulated geothermal test fluid. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 6 and 11.7.

  13. Microbiological methods for the water recovery systems test, revision 1.1

    Science.gov (United States)

    Rhoads, Tim; Kilgore, M. V., Jr.; Mikell, A. T., Jr.

    1990-01-01

    Current microbiological parameters specified to verify microbiological quality of Space Station Freedom water quality include the enumeration of total bacteria, anaerobes, aerobes, yeasts and molds, enteric bacteria, gram positives, gram negatives, and E. coli. In addition, other parameters have been identified as necessary to support the Water Recovery Test activities to be conducted at the NASA/MSFC later this year. These other parameters include aerotolerant eutrophic mesophiles, legionellae, and an additional method for heterotrophic bacteria. If inter-laboratory data are to be compared to evaluate quality, analytical methods must be eliminated as a variable. Therefore, each participating laboratory must utilize the same analytical methods and procedures. Without this standardization, data can be neither compared nor validated between laboratories. Multiple laboratory participation represents a conservative approach to insure quality and completeness of data. Invariably, sample loss will occur in transport and analyses. Natural variance is a reality on any test of this magnitude and is further enhanced because biological entities, capable of growth and death, are specific parameters of interest. The large variation due to the participation of human test subjects has been noted with previous testing. The resultant data might be dismissed as 'out of control' unless intra-laboratory control is included as part of the method or if participating laboratories are not available for verification. The purpose of this document is to provide standardized laboratory procedures for the enumeration of certain microorganisms in water and wastewater specific to the water recovery systems test. The document consists of ten separate cultural methods and one direct count procedure. It is not intended nor is it implied to be a complete microbiological methods manual.

  14. 40 CFR 1039.505 - How do I test engines using steady-state duty cycles, including ramped-modal testing?

    Science.gov (United States)

    2010-07-01

    ...-state duty cycles, including ramped-modal testing? 1039.505 Section 1039.505 Protection of Environment... duty cycles, including ramped-modal testing? This section describes how to test engines under steady-state conditions. In some cases, we allow you to choose the appropriate steady-state duty cycle for an...

  15. Considerations and Methods for Usability Testing with Children

    DEFF Research Database (Denmark)

    Andersen, Malene Hjortboe; Khalid, Md. Saifuddin; Brooks, Eva Irene

    2017-01-01

    of these methods is that they are designed for adults and are not necessarily appropriate to investigations including children. The guiding questions for this systematic literature review are (1) the motivation for conducting usability tests with children, and (2) the kind of methodological, practical, and ethical...

  16. 40 CFR 63.547 - Test methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Test methods. 63.547 Section 63.547... Hazardous Air Pollutants from Secondary Lead Smelting § 63.547 Test methods. (a) The following test methods...), and 63.545(e): (1) Method 1 shall be used to select the sampling port location and the number of...

  17. Materials and test methods

    International Nuclear Information System (INIS)

    Kase, M.B.

    1985-01-01

    The objective of this study was to provide, in cooperation with ORNL and LANL, specimens required for studies to develop organic insulators having the cryogenic neutron irradiation resistance required for MFE systems utilizing superconducting magnetic confinement. To develop test methods and analytical procedures for assessing radiation damage. To stimulate and participate in international cooperation directed toward accomplishing these objectives. The system for producing uniaxially reinforced, 3-4 mm (0.125 in) diameter rod specimens has been refined and validated by production of excellent quality specimens using liquid-mix epoxy resin systems. The methodology is undergoing further modification to permit use of hot-melt epoxy and polyimide resin systems as will be required for the experimental program to be conducted in the NLTNIF reactor at ORNL. Preliminary studies indicate that short beam and torsional shear test methods will be useful in evaluating radiation degradation. Development of these and other applicable test methods are continuing. A cooperative program established with laboratories in Japan and in England has resulted in the production and testing of specimens having an identical configuration

  18. Radon barrier: Method of testing airtightness

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn; Buch-Hansen, Thomas Cornelius

    2017-01-01

    The test method NBI 167/02 Radon membrane: Test of airtightness can be used for determining the airtightness of a radon barrier as a system solution. The test determines the air infiltration through the radon barrier for a number of levels of air pressure differences. The airflow through versus...... of the barrier with the low air pressure, through a well-defined opening, as a modification of the test method in general. Results, obtained using the improved test method, are shown for a number of radon barriers tested....

  19. Preliminary Tests For Development Of A Non-Pertechnetate Analysis Method

    Energy Technology Data Exchange (ETDEWEB)

    Diprete, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); McCabe, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-09-28

    The objective of this task was to develop a non-pertechnetate analysis method that 222-S lab could easily implement. The initial scope involved working with 222-S laboratory personnel to adapt the existing Tc analytical method to fractionate the non-pertechnetate and pertechnetate. SRNL then developed and tested a method using commercial sorbents containing Aliquat® 336 to extract the pertechnetate (thereby separating it from non-pertechnetate), followed by oxidation, extraction, and stripping steps, and finally analysis by beta counting and Mass Spectroscopy. Several additional items were partially investigated, including impacts of a 137Cs removal step. The method was initially tested on SRS tank waste samples to determine its viability. Although SRS tank waste does not contain non-pertechnetate, testing with it was useful to investigate the compatibility, separation efficiency, interference removal efficacy, and method sensitivity.

  20. Test method research on weakening interface strength of steel - concrete under cyclic loading

    Science.gov (United States)

    Liu, Ming-wei; Zhang, Fang-hua; Su, Guang-quan

    2018-02-01

    The mechanical properties of steel - concrete interface under cyclic loading are the key factors affecting the rule of horizontal load transfer, the calculation of bearing capacity and cumulative horizontal deformation. Cyclic shear test is an effective method to study the strength reduction of steel - concrete interface. A test system composed of large repeated direct shear test instrument, hydraulic servo system, data acquisition system, test control software system and so on is independently designed, and a set of test method, including the specimen preparation, the instrument preparation, the loading method and so on, is put forward. By listing a set of test results, the validity of the test method is verified. The test system and the test method based on it provide a reference for the experimental study on mechanical properties of steel - concrete interface.

  1. Implementation aspects of the Boundary Element Method including viscous and thermal losses

    DEFF Research Database (Denmark)

    Cutanda Henriquez, Vicente; Juhl, Peter Møller

    2014-01-01

    The implementation of viscous and thermal losses using the Boundary Element Method (BEM) is based on the Kirchhoff’s dispersion relation and has been tested in previous work using analytical test cases and comparison with measurements. Numerical methods that can simulate sound fields in fluids...

  2. 40 CFR 80.3 - Test methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Test methods. 80.3 Section 80.3... FUELS AND FUEL ADDITIVES General Provisions § 80.3 Test methods. The lead and phosphorus content of gasoline shall be determined in accordance with test methods set forth in the appendices to this part. [47...

  3. 40 CFR 63.1546 - Test methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Test methods. 63.1546 Section 63.1546... Hazardous Air Pollutants for Primary Lead Smelting § 63.1546 Test methods. (a) The following procedure shall....1543(a)(1) through § 63.1543(a)(9) shall be determined according to the following test methods in...

  4. 30 CFR 27.31 - Testing methods.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Testing methods. 27.31 Section 27.31 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Test Requirements § 27.31 Testing methods. A methane...

  5. Audit of Trichomonas vaginalis test requesting by community referrers after a change from culture to molecular testing, including a cost analysis.

    Science.gov (United States)

    Bissessor, Liselle; Wilson, Janet; McAuliffe, Gary; Upton, Arlo

    2017-06-16

    Trichomonas vaginalis (TV) prevalence varies among different communities and peoples. The availability of robust molecular platforms for the detection of TV has advanced diagnosis; however, molecular tests are more costly than phenotypic methodologies, and testing all urogenital samples is costly. We recently replaced culture methods with the Aptima Trichomonas vaginalis nucleic acid amplification test on specific request and as reflex testing by the laboratory, and have audited this change. Data were collected from August 2015 (microbroth culture and microscopy) and August 2016 (Aptima TV assay) including referrer, testing volumes, results and test cost estimates. In August 2015, 10,299 vaginal swabs, and in August 2016, 2,189 specimens (urogenital swabs and urines), were tested. The positivity rate went from 0.9% to 5.3%, and overall more TV infections were detected in 2016. The number needed to test and cost for one positive TV result respectively was 111 and $902.55 in 2015, and 19 and $368.92 in 2016. Request volumes and positivity rates differed among referrers. The methodology change was associated with higher overall detection of TV, and reductions in the numbers needed to test/cost for one TV diagnosis. Our audit suggests that there is room for improvement with TV test requesting in our community.

  6. A Teaching Method on Basic Chemistry for Freshman : Teaching Method with Pre-test and Post-test

    OpenAIRE

    立木, 次郎; 武井, 庚二

    2003-01-01

    This report deals with a teaching method on basic chemistry for freshman. This teaching method contains guidance and instruction to how to understand basic chemistry. Pre-test and post-test have been put into practice each time. Each test was returned to students at class in the following weeks.

  7. Field Testing of Compartmentalization Methods for Multifamily Construction

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K. [Building Science Corporation, Westford, MA (United States); Lstiburek, J. [Building Science Corporation, Westford, MA (United States)

    2015-03-01

    The 2012 IECC has an airtightness requirement of 3 air changes per hour at 50 Pascals test pressure for both single-family and multifamily construction in Climate Zones 3-8. Other programs (LEED, ASHRAE 189, ASHRAE 62.2) have similar or tighter compartmentalization requirements, driving the need for easier and more effective methods of compartmentalization in multifamily buildings. Builders and practitioners have found that fire-resistance rated wall assemblies are a major source of difficulty in air sealing/compartmentalization, particularly in townhouse construction. This problem is exacerbated when garages are “tucked in” to the units and living space is located over the garages. In this project, Building Science Corporation examined the taping of exterior sheathing details to improve air sealing results in townhouse and multifamily construction, when coupled with a better understanding of air leakage pathways. Current approaches are cumbersome, expensive, time consuming, and ineffective; these details were proposed as a more effective and efficient method. The effectiveness of these air sealing methods was tested with blower door testing, including “nulled” or “guarded” testing (adjacent units run at equal test pressure to null out inter-unit air leakage, or “pressure neutralization”). Pressure diagnostics were used to evaluate unit-to-unit connections and series leakage pathways (i.e., air leakage from exterior, into the fire-resistance rated wall assembly, and to the interior).

  8. Standard test methods for characterizing duplex grain sizes

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 These test methods provide simple guidelines for deciding whether a duplex grain size exists. The test methods separate duplex grain sizes into one of two distinct classes, then into specific types within those classes, and provide systems for grain size characterization of each type. 1.2 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns associated with its use. It is the responsibility of the user of this standard to consult appropriate safety and health practices and determine the applicability of regulatory limitations prior to its use.

  9. 40 CFR 63.344 - Performance test requirements and test methods.

    Science.gov (United States)

    2010-07-01

    ... electroplating tanks or chromium anodizing tanks. The sampling time and sample volume for each run of Methods 306... Chromium Anodizing Tanks § 63.344 Performance test requirements and test methods. (a) Performance test... Emissions From Decorative and Hard Chromium Electroplating and Anodizing Operations,” appendix A of this...

  10. Standard test method for isotopic analysis of uranium hexafluoride by double standard single-collector gas mass spectrometer method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This is a quantitative test method applicable to determining the mass percent of uranium isotopes in uranium hexafluoride (UF6) samples with 235U concentrations between 0.1 and 5.0 mass %. 1.2 This test method may be applicable for the entire range of 235U concentrations for which adequate standards are available. 1.3 This test method is for analysis by a gas magnetic sector mass spectrometer with a single collector using interpolation to determine the isotopic concentration of an unknown sample between two characterized UF6 standards. 1.4 This test method is to replace the existing test method currently published in Test Methods C761 and is used in the nuclear fuel cycle for UF6 isotopic analyses. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appro...

  11. Standard Test Methods for Properties of Continuous Filament Carbon and Graphite Fiber Tows

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 These test methods cover the preparation and tensile testing of resin-impregnated and consolidated test specimens made from continuous filament carbon and graphite yarns, rovings, and tows to determine their tensile properties. 1.2 These test methods also cover the determination of the density and mass per unit length of the yarn, roving, or tow to provide supplementary data for tensile property calculation. 1.3 These test methods include a procedure for sizing removal to provide the preferred desized fiber samples for density measurement. This procedure may also be used to determine the weight percent sizing. 1.4 These test methods include a procedure for determining the weight percent moisture adsorption of carbon or graphite fiber. 1.5 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of t...

  12. 7 CFR 58.644 - Test methods.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Test methods. 58.644 Section 58.644 Agriculture... Procedures § 58.644 Test methods. (a) Microbiological. Microbiological determinations shall be made in accordance with the methods described in the latest edition of Standard Methods for the Examination of Dairy...

  13. The influence of technical testing methods on perceptions of constructions

    International Nuclear Information System (INIS)

    Oestberg, Gustaf

    2002-01-01

    In principle, methods of testing the reliability and safety of constructions are designed with the aim of representing critical conditions for their use. Because of variations within technical systems, including the one for which a certain test was once developed, the validity of the method also varies. The adoption of a standardized test for different applications had to be based on the assumption that the test deals adequately with a real situation. As a consequence of this acceptance of a trustworthy relationship between test and reality, an imprint of the former on the latter occurs. This effect may even cause the perception of a reality to be defined by the corresponding test. Examples of such an influence may be found in the field of materials testing. Related phenomena can be dealt with by reference to current concepts of cognitive science and psychology of the perception of images

  14. Systematic evaluation of non-animal test methods for skin sensitisation safety assessment.

    Science.gov (United States)

    Reisinger, Kerstin; Hoffmann, Sebastian; Alépée, Nathalie; Ashikaga, Takao; Barroso, Joao; Elcombe, Cliff; Gellatly, Nicola; Galbiati, Valentina; Gibbs, Susan; Groux, Hervé; Hibatallah, Jalila; Keller, Donald; Kern, Petra; Klaric, Martina; Kolle, Susanne; Kuehnl, Jochen; Lambrechts, Nathalie; Lindstedt, Malin; Millet, Marion; Martinozzi-Teissier, Silvia; Natsch, Andreas; Petersohn, Dirk; Pike, Ian; Sakaguchi, Hitoshi; Schepky, Andreas; Tailhardat, Magalie; Templier, Marie; van Vliet, Erwin; Maxwell, Gavin

    2015-02-01

    The need for non-animal data to assess skin sensitisation properties of substances, especially cosmetics ingredients, has spawned the development of many in vitro methods. As it is widely believed that no single method can provide a solution, the Cosmetics Europe Skin Tolerance Task Force has defined a three-phase framework for the development of a non-animal testing strategy for skin sensitization potency prediction. The results of the first phase – systematic evaluation of 16 test methods – are presented here. This evaluation involved generation of data on a common set of ten substances in all methods and systematic collation of information including the level of standardisation, existing test data,potential for throughput, transferability and accessibility in cooperation with the test method developers.A workshop was held with the test method developers to review the outcome of this evaluation and to discuss the results. The evaluation informed the prioritisation of test methods for the next phase of the non-animal testing strategy development framework. Ultimately, the testing strategy – combined with bioavailability and skin metabolism data and exposure consideration – is envisaged to allow establishment of a data integration approach for skin sensitisation safety assessment of cosmetic ingredients.

  15. Test Methods for Evaluating Solid Waste, Physical/Chemical Methods. First Update. (3rd edition)

    International Nuclear Information System (INIS)

    Friedman; Sellers.

    1988-01-01

    The proposed Update is for Test Methods for Evaluating Solid Waste, Physical/Chemical Methods, SW-846, Third Edition. Attached to the report is a list of methods included in the proposed update indicating whether the method is a new method, a partially revised method, or a totally revised method. Do not discard or replace any of the current pages in the SW-846 manual until the proposed update I package is promulgated. Until promulgation of the update package, the methods in the update package are not officially part of the SW-846 manual and thus do not carry the status of EPA-approved methods. In addition to the proposed Update, six finalized methods are included for immediate inclusion into the Third Edition of SW-846. Four methods, originally proposed October 1, 1984, will be finalized in a soon to be released rulemaking. They are, however, being submitted to subscribers for the first time in the update. These methods are 7211, 7381, 7461, and 7951. Two other methods were finalized in the 2nd Edition of SW-846. They were inadvertantly omitted from the 3rd Edition and are not being proposed as new. These methods are 7081 and 7761

  16. A Test Method for Monitoring Modulus Changes during Durability Tests on Building Joint Sealants

    Science.gov (United States)

    Christopher C. White; Donald L. Hunston; Kar Tean Tan; Gregory T. Schueneman

    2012-01-01

    The durability of building joint sealants is generally assessed using a descriptive methodology involving visual inspection of exposed specimens for defects. It is widely known that this methodology has inherent limitations, including that the results are qualitative. A new test method is proposed that provides more fundamental and quantitative information about...

  17. [Inappropriate test methods in allergy].

    Science.gov (United States)

    Kleine-Tebbe, J; Herold, D A

    2010-11-01

    Inappropriate test methods are increasingly utilized to diagnose allergy. They fall into two categories: I. Tests with obscure theoretical basis, missing validity and lacking reproducibility, such as bioresonance, electroacupuncture, applied kinesiology and the ALCAT-test. These methods lack both the technical and clinical validation needed to justify their use. II. Tests with real data, but misleading interpretation: Detection of IgG or IgG4-antibodies or lymphocyte proliferation tests to foods do not allow to separate healthy from diseased subjects, neither in case of food intolerance, allergy or other diagnoses. The absence of diagnostic specificity induces many false positive findings in healthy subjects. As a result unjustified diets might limit quality of life and lead to malnutrition. Proliferation of lymphocytes in response to foods can show elevated rates in patients with allergies. These values do not allow individual diagnosis of hypersensitivity due to their broad variation. Successful internet marketing, infiltration of academic programs and superficial reporting by the media promote the popularity of unqualified diagnostic tests; also in allergy. Therefore, critical observation and quick analysis of and clear comments to unqualified methods by the scientific medical societies are more important than ever.

  18. Test methods for the dynamic mechanical properties of polymeric materials. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Baker, G.K.

    1980-06-01

    Various test geometries and procedures for the dynamic mechanical analysis of polymers employing a mechanical spectrometer have been evaluated. The methods and materials included in this work are forced torsional pendulum testing of Kevlar/epoxy laminates and rigid urethane foams, oscillatory parallel plate testing to determine the kinetics of the cure of VCE with Hylene MP, oscillatory compressive testing of B-3223 cellular silicone, and oscillatory tensile testing of Silastic E and single Kevlar filaments. Fundamental dynamic mechanical properties, including the storage and loss moduli and loss tangent of the materials tested, were determined as a function of temperature and sometimes of frequency.

  19. 30 CFR 36.41 - Testing methods.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Testing methods. 36.41 Section 36.41 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF... Requirements § 36.41 Testing methods. Mobile diesel-powered transportation equipment submitted for...

  20. Standard test method for determination of surface lubrication on flexible webs

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method has been used since 1988 as an ANSI/ISO standard test for determination of lubrication on processed photographic films. Its purpose was to determine the presence of process-surviving lubricants on photographic films. It is the purpose of this test method to expand the applicability of this test method to other flexible webs that may need lubrication for suitable performance. This test measures the breakaway (static) coefficient of friction of a metal rider on the web by the inclined plane method. The objectives of the test is to determine if a web surface has a lubricant present or not. It is not intended to assign a friction coefficient to a material. It is not intended to rank lubricants. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish ...

  1. Standard Test Method for Determining the Linearity of a Photovoltaic Device Parameter with Respect To a Test Parameter

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method determines the degree of linearity of a photovoltaic device parameter with respect to a test parameter, for example, short-circuit current with respect to irradiance. 1.2 The linearity determined by this test method applies only at the time of testing, and implies no past or future performance level. 1.3 This test method applies only to non-concentrator terrestrial photovoltaic devices. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. Including osteoprotegerin and collagen IV in a score-based blood test for liver fibrosis increases diagnostic accuracy.

    Science.gov (United States)

    Bosselut, Nelly; Taibi, Ludmia; Guéchot, Jérôme; Zarski, Jean-Pierre; Sturm, Nathalie; Gelineau, Marie-Christine; Poggi, Bernard; Thoret, Sophie; Lasnier, Elisabeth; Baudin, Bruno; Housset, Chantal; Vaubourdolle, Michel

    2013-01-16

    Noninvasive methods for liver fibrosis evaluation in chronic liver diseases have been recently developed, i.e. transient elastography (Fibroscan™) and blood tests (Fibrometer®, Fibrotest®, and Hepascore®). In this study, we aimed to design a new score in chronic hepatitis C (CHC) by selecting blood markers in a large panel and we compared its diagnostic performance with those of other noninvasive methods. Sixteen blood tests were performed in 306 untreated CHC patients included in a multicenter prospective study (ANRS HC EP 23 Fibrostar) using METAVIR histological fibrosis stage as reference. The new score was constructed by non linear regression using the most accurate biomarkers. Five markers (alpha-2-macroglobulin, apolipoprotein-A1, AST, collagen IV and osteoprotegerin) were included in the new function called Coopscore©. Using the Obuchowski Index, Coopscore© shows higher diagnostic performances than for Fibrometer®, Fibrotest®, Hepascore® and Fibroscan™ in CHC. Association between Fibroscan™ and Coopscore© might avoid 68% of liver biopsies for the diagnosis of significant fibrosis. Coopscore© provides higher accuracy than other noninvasive methods for the diagnosis of liver fibrosis in CHC. The association of Coopscore© with Fibroscan™ increases its predictive value. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Standard test method for nondestructive assay of special nuclear material holdup using Gamma-Ray spectroscopic methods

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method describes gamma-ray methods used to nondestructively measure the quantity of 235U, or 239Pu remaining as holdup in nuclear facilities. Holdup occurs in all facilities where nuclear material is processed, in process equipment, in exhaust ventilation systems and in building walls and floors. 1.2 This test method includes information useful for management, planning, selection of equipment, consideration of interferences, measurement program definition, and the utilization of resources (1, 2, 3, 4). 1.3 The measurement of nuclear material hold up in process equipment requires a scientific knowledge of radiation sources and detectors, transmission of radiation, calibration, facility operations and error analysis. It is subject to the constraints of the facility, management, budget, and schedule; plus health and safety requirements; as well as the laws of physics. The measurement process includes defining measurement uncertainties and is sensitive to the form and distribution of the material...

  4. Standard Test Methods for Wet Insulation Integrity Testing of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 These test methods provide procedures to determine the insulation resistance of a photovoltaic (PV) module, i.e. the electrical resistance between the module's internal electrical components and its exposed, electrically conductive, non-current carrying parts and surfaces. 1.2 The insulation integrity procedures are a combination of wet insulation resistance and wet dielectric voltage withstand test procedures. 1.3 These procedures are similar to and reference the insulation integrity test procedures described in Test Methods E 1462, with the difference being that the photovoltaic module under test is immersed in a wetting solution during the procedures. 1.4 These test methods do not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of these test methods. 1.5 The values stated in SI units are to be regarded as the standard. 1.6 There is no similar or equivalent ISO standard. 1.7 This standard does not purport to address all of the safety conce...

  5. Advantages and limitations of common testing methods for antioxidants.

    Science.gov (United States)

    Amorati, R; Valgimigli, L

    2015-05-01

    Owing to the importance of antioxidants in the protection of both natural and man-made materials, a large variety of testing methods have been proposed and applied. These include methods based on inhibited autoxidation studies, which are better followed by monitoring the kinetics of oxygen consumption or of the formation of hydroperoxides, the primary oxidation products. Analytical determination of secondary oxidation products (e.g. carbonyl compounds) has also been used. The majority of testing methods, however, do not involve substrate autoxidation. They are based on the competitive bleaching of a probe (e.g. ORAC assay, β-carotene, crocin bleaching assays, and luminol assay), on reaction with a different probe (e.g. spin-trapping and TOSC assay), or they are indirect methods based on the reduction of persistent radicals (e.g. galvinoxyl, DPPH and TEAC assays), or of inorganic oxidizing species (e.g. FRAP, CUPRAC and Folin-Ciocalteu assays). Yet other methods are specific for preventive antioxidants. The relevance, advantages, and limitations of these methods are critically discussed, with respect to their chemistry and the mechanisms of antioxidant activity. A variety of cell-based assays have also been proposed, to investigate the biological activity of antioxidants. Their importance and critical aspects are discussed, along with arguments for the selection of the appropriate testing methods according to the different needs.

  6. Myasthenia Gravis: Tests and Diagnostic Methods

    Science.gov (United States)

    ... Focus on MG Newsletter MG Quarterly Test & Diagnostic methods In addition to a complete medical and neurological ... How can I help? About MGFA Test & Diagnostic methods Treatment for MG FAQ's Upcoming Events 2018 MG ...

  7. A comprehensive review of regulatory test methods for endocrine adverse health effects.

    Science.gov (United States)

    Manibusan, M K; Touart, L W

    2017-07-01

    Development of new endocrine disruption-relevant test methods has been the subject of intensive research efforts for the past several decades, prompted in part by mandates in the 1996 Food Quality Protection Act (FQPA). While scientific understanding and test methods have advanced, questions remain on whether current scientific methods are capable of adequately addressing the complexities of the endocrine system for regulatory health and ecological risk assessments. The specific objective of this article is to perform a comprehensive, detailed evaluation of the adequacy of current test methods to inform regulatory risk assessments of whether a substance has the potential to perturb endocrine-related pathways resulting in human adverse effects. To that end,  approximately 42 existing test guidelines (TGs) were considered in the evaluation of coverage for endocrine-related adverse effects. In addition to evaluations of whether test methods are adequate to capture endocrine-related effects, considerations of further enhancements to current test methods, along with the need to develop novel test methods to address existing test method gaps are described. From this specific evaluation, up to 35 test methods are capable of informing whether a chemical substance perturbs known endocrine related biological pathways. Based on these findings, it can be concluded that current validated test methods are adequate to discern substances that may perturb the endocrine system, resulting in an adverse health effect. Together, these test methods predominantly form the core data requirements of a typical food-use pesticide registration submission. It is recognized, however, that the current state of science is rapidly advancing and there is a need to update current test methods to include added enhancements to ensure continued coverage and public health and environmental protection.

  8. Development of Dissolution Test Method for Drotaverine ...

    African Journals Online (AJOL)

    Development of Dissolution Test Method for Drotaverine ... Methods: Sink conditions, drug stability and specificity in different dissolution media were tested to optimize a dissolution test .... test by Prism 4.0 software, and differences between ...

  9. Allergic Contact Dermatitis to Ophthalmic Medications: Relevant Allergens and Alternative Testing Methods.

    Science.gov (United States)

    Grey, Katherine R; Warshaw, Erin M

    Allergic contact dermatitis is an important cause of periorbital dermatitis. Topical ophthalmic agents are relevant sensitizers. Contact dermatitis to ophthalmic medications can be challenging to diagnose and manage given the numerous possible offending agents, including both active and inactive ingredients. Furthermore, a substantial body of literature reports false-negative patch test results to ophthalmic agents. Subsequently, numerous alternative testing methods have been described. This review outlines the periorbital manifestations, causative agents, and alternative testing methods of allergic contact dermatitis to ophthalmic medications.

  10. New Graphical Methods and Test Statistics for Testing Composite Normality

    Directory of Open Access Journals (Sweden)

    Marc S. Paolella

    2015-07-01

    Full Text Available Several graphical methods for testing univariate composite normality from an i.i.d. sample are presented. They are endowed with correct simultaneous error bounds and yield size-correct tests. As all are based on the empirical CDF, they are also consistent for all alternatives. For one test, called the modified stabilized probability test, or MSP, a highly simplified computational method is derived, which delivers the test statistic and also a highly accurate p-value approximation, essentially instantaneously. The MSP test is demonstrated to have higher power against asymmetric alternatives than the well-known and powerful Jarque-Bera test. A further size-correct test, based on combining two test statistics, is shown to have yet higher power. The methodology employed is fully general and can be applied to any i.i.d. univariate continuous distribution setting.

  11. Membrane for distillation including nanostructures, methods of making membranes, and methods of desalination and separation

    KAUST Repository

    Lai, Zhiping; Huang, Kuo-Wei; Chen, Wei

    2016-01-01

    In accordance with the purpose(s) of the present disclosure, as embodied and broadly described herein, embodiments of the present disclosure provide membranes, methods of making the membrane, systems including the membrane, methods of separation, methods of desalination, and the like.

  12. Membrane for distillation including nanostructures, methods of making membranes, and methods of desalination and separation

    KAUST Repository

    Lai, Zhiping

    2016-01-21

    In accordance with the purpose(s) of the present disclosure, as embodied and broadly described herein, embodiments of the present disclosure provide membranes, methods of making the membrane, systems including the membrane, methods of separation, methods of desalination, and the like.

  13. Standard test methods for arsenic in uranium hexafluoride

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 These test methods are applicable to the determination of total arsenic in uranium hexafluoride (UF6) by atomic absorption spectrometry. Two test methods are given: Test Method A—Arsine Generation-Atomic Absorption (Sections 5-10), and Test Method B—Graphite Furnace Atomic Absorption (Appendix X1). 1.2 The test methods are equivalent. The limit of detection for each test method is 0.1 μg As/g U when using a sample containing 0.5 to 1.0 g U. Test Method B does not have the complete collection details for precision and bias data thus the method appears as an appendix. 1.3 Test Method A covers the measurement of arsenic in uranyl fluoride (UO2F2) solutions by converting arsenic to arsine and measuring the arsine vapor by flame atomic absorption spectrometry. 1.4 Test Method B utilizes a solvent extraction to remove the uranium from the UO2F2 solution prior to measurement of the arsenic by graphite furnace atomic absorption spectrometry. 1.5 Both insoluble and soluble arsenic are measured when UF6 is...

  14. Comparative study of durability test methods for pellets and briquettes

    Energy Technology Data Exchange (ETDEWEB)

    Temmerman, Michaeel; Rabier, Fabienne [Centre wallon de Recherches agronomiques (CRA-W), 146, chaussee de Namur, B-5030, Gembloux (Belgium); Jensen, Peter Daugbjerg [Forest and Landscape, The Royal Veterinary and Agricultural University, Rolighedsvej 23, DK-1958 Frederiksberg C (Denmark); Hartmann, Hans; Boehm, Thorsten [Technologie- und Foerderzentrum fuer Nachwachsende Rohstoffe-TFZ, Schulgasse 18, D-94315 Straubing (Germany)

    2006-11-15

    Different methods for the determination of the mechanical durability (DU) of pellets and briquettes were compared by international round robin tests including different laboratories. The DUs of five briquette and 26 pellet types were determined. For briquettes, different rotation numbers of a prototype tumbler and a calculated DU index are compared. For pellets testing, the study compares two standard methods, a tumbling device according to ASAE S 269.4, the Lignotester according to ONORM M 7135 and a second tumbling method with a prototype tumbler. For the tested methods, the repeatability, the reproducibility and the required minimum number of replications to achieve given accuracy levels were calculated. Additionally, this study evaluates the relation between DU and particle density. The results show for both pellets and briquettes, that the measured DU values and their variability are influenced by the applied method. Moreover, the variability of the results depend on the biofuel itself. For briquettes of DU above 90%, five replications lead to an accuracy of 2%, while 39 replications are needed to achieve an accuracy of 10%, when briquettes of DU below 90% are tested. For pellets, the tumbling device described by the ASAE standard allows to reach acceptable accuracy levels (1%) with a limited number of replications. Finally, for the tested pellets and briquettes no relation between DU and particle density was found. (author)

  15. 40 CFR 63.465 - Test methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Test methods. 63.465 Section 63.465... Halogenated Solvent Cleaning § 63.465 Test methods. (a) Except as provided in paragraphs (f) and (g) of this... Reference Method 307 in appendix A of this part. (b) Except as provided in paragraph (g) of this section for...

  16. A Method to Select Test Input Cases for Safety-critical Software

    International Nuclear Information System (INIS)

    Kim, Heeeun; Kang, Hyungook; Son, Hanseong

    2013-01-01

    This paper proposes a new testing methodology for effective and realistic quantification of RPS software failure probability. Software failure probability quantification is important factor in digital system safety assessment. In this study, the method for software test case generation is briefly described. The test cases generated by this method reflect the characteristics of safety-critical software and past inputs. Furthermore, the number of test cases can be reduced, but it is possible to perform exhaustive test. Aspect of software also can be reflected as failure data, so the final failure data can include the failure of software itself and external influences. Software reliability is generally accepted as the key factor in software quality since it quantifies software failures which can make a powerful system inoperative. In the KNITS (Korea Nuclear Instrumentation and Control Systems) project, the software for the fully digitalized reactor protection system (RPS) was developed under a strict procedure including unit testing and coverage measurement. Black box testing is one type of Verification and validation (V and V), in which given input values are entered and the resulting output values are compared against the expected output values. Programmable logic controllers (PLCs) were used in implementing critical systems and function block diagram (FBD) is a commonly used implementation language for PLC

  17. Standard test method for dynamic tear testing of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1983-01-01

    1.1 This test method covers the dynamic tear (DT) test using specimens that are 3/16 in. to 5/8 in. (5 mm to 16 mm) inclusive in thickness. 1.2 This test method is applicable to materials with a minimum thickness of 3/16 in. (5 mm). 1.3 The pressed-knife procedure described for sharpening the notch tip generally limits this test method to materials with a hardness level less than 36 HRC. Note 1—The designation 36 HRC is a Rockwell hardness number of 36 on Rockwell C scale as defined in Test Methods E 18. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  18. Alternative containment integrity test methods, an overview of possible techniques

    International Nuclear Information System (INIS)

    Spletzer, B.L.

    1986-01-01

    A study is being conducted to develop and analyze alternative methods for testing of containment integrity. The study is focused on techniques for continuously monitoring containment integrity to provide rapid detection of existing leaks, thus providing greater certainty of the integrity of the containment at any time. The study is also intended to develop techniques applicable to the currently required Type A integrated leakage rate tests. A brief discussion of the range of alternative methods currently being considered is presented. The methods include applicability to all major containment types, operating and shutdown plant conditions, and quantitative and qualitative leakage measurements. The techniques are analyzed in accordance with the current state of knowledge of each method. The bulk of the techniques discussed are in the conceptual stage, have not been tested in actual plant conditions, and are presented here as a possible future direction for evaluating containment integrity. Of the methods considered, no single method provides optimum performance for all containment types. Several methods are limited in the types of containment for which they are applicable. The results of the study to date indicate that techniques for continuous monitoring of containment integrity exist for many plants and may be implemented at modest cost

  19. 40 CFR 59.207 - Test methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Test methods. 59.207 Section 59.207 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... Compound Emission Standards for Consumer Products § 59.207 Test methods. Each manufacturer or importer...

  20. [Seed quality test methods of Paeonia suffruticosa].

    Science.gov (United States)

    Cao, Ya-Yue; Zhu, Zai-Biao; Guo, Qiao-Sheng; Liu, Li; Wang, Chang-Lin

    2014-11-01

    In order to optimize the testing methods for Paeonia suffruticosa seed quality, and provide basis for establishing seed testing rules and seed quality standard of P. suffruticosa. The seed quality of P. suffruticosa from different producing areas was measured based on the related seed testing regulations. The seed testing methods for quality items of P. suffruticosa was established preliminarily. The samples weight of P. suffruticosa was at least 7 000 g for purity analysis and was at least 700 g for test. The phenotypic observation and size measurement were used for authenticity testing. The 1 000-seed weight was determined by 100-seed method, and the water content was carried out by low temperature drying method (10 hours). After soaking in distilled water for 24 h, the seeds was treated with different temperature stratifications of day and night (25 degrees C/20 degrees C, day/night) in the dark for 60 d. After soaking in the liquor of GA3 300 mg x L(-1) for 24 h, the P. suffruticos seeds were cultured in wet sand at 15 degrees C for 12-60 days for germination testing. Seed viability was tested by TlC method.

  1. Standard Test Method for Sandwich Corrosion Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method defines the procedure for evaluating the corrosivity of aircraft maintenance chemicals, when present between faying surfaces (sandwich) of aluminum alloys commonly used for aircraft structures. This test method is intended to be used in the qualification and approval of compounds employed in aircraft maintenance operations. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information. 1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements appear in Section 9.

  2. 40 CFR 1048.505 - How do I test engines using steady-state duty cycles, including ramped-modal testing?

    Science.gov (United States)

    2010-07-01

    ...-state duty cycles, including ramped-modal testing? 1048.505 Section 1048.505 Protection of Environment... SPARK-IGNITION ENGINES Test Procedures § 1048.505 How do I test engines using steady-state duty cycles... some cases, we allow you to choose the appropriate steady-state duty cycle for an engine. In these...

  3. Standard test method for plutonium assay by plutonium (III) diode array spectrophotometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method describes the determination of total plutonium as plutonium(III) in nitrate and chloride solutions. The technique is applicable to solutions of plutonium dioxide powders and pellets (Test Methods C 697), nuclear grade mixed oxides (Test Methods C 698), plutonium metal (Test Methods C 758), and plutonium nitrate solutions (Test Methods C 759). Solid samples are dissolved using the appropriate dissolution techniques described in Practice C 1168. The use of this technique for other plutonium-bearing materials has been reported (1-5), but final determination of applicability must be made by the user. The applicable concentration range for plutonium sample solutions is 10–200 g Pu/L. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropria...

  4. Test Methods for Robot Agility in Manufacturing.

    Science.gov (United States)

    Downs, Anthony; Harrison, William; Schlenoff, Craig

    2016-01-01

    The paper aims to define and describe test methods and metrics to assess industrial robot system agility in both simulation and in reality. The paper describes test methods and associated quantitative and qualitative metrics for assessing robot system efficiency and effectiveness which can then be used for the assessment of system agility. The paper describes how the test methods were implemented in a simulation environment and real world environment. It also shows how the metrics are measured and assessed as they would be in a future competition. The test methods described in this paper will push forward the state of the art in software agility for manufacturing robots, allowing small and medium manufacturers to better utilize robotic systems. The paper fulfills the identified need for standard test methods to measure and allow for improvement in software agility for manufacturing robots.

  5. Automated Test Methods for XML Metadata

    Science.gov (United States)

    2017-12-28

    8933 Com (661) 277 8933 email jon.morgan.2.ctr@us.af.mil Secretariat, Range Commanders Council ATTN: TEDT-WS-RCC 1510 Headquarters Avenue White...Sands Missile Range, New Mexico 88002-5110 Phone: DSN 258-1107 Com (575) 678-1107 Fax: DSN 258-7519 Com (575) 678-7519 email ...Method for Testing Syntax The test method is as follows. 1. Initialize the programming environment. 2. Write test application code to use the

  6. New Rock Abrasivity Test Method for Tool Life Assessments on Hard Rock Tunnel Boring: The Rolling Indentation Abrasion Test (RIAT)

    Science.gov (United States)

    Macias, F. J.; Dahl, F.; Bruland, A.

    2016-05-01

    The tunnel boring machine (TBM) method has become widely used and is currently an important presence within the tunnelling industry. Large investments and high geological risk are involved using TBMs, and disc cutter consumption has a great influence on performance and cost, especially in hard rock conditions. Furthermore, reliable cutter life assessments facilitate the control of risk as well as avoiding delays and budget overruns. Since abrasive wear is the most common process affecting cutter consumption, good laboratory tests for rock abrasivity assessments are needed. A new abrasivity test method by rolling disc named Rolling Indentation Abrasion Test (RIAT) has been developed. The goal of the new test design and procedure is to reproduce wear behaviour on hard rock tunnel boring in a more realistic way than the traditionally used methods. Wear by rolling contact on intact rock samples is introduced and several rock types, covering a wide rock abrasiveness range, have been tested by RIAT. The RIAT procedure indicates a great ability of the testing method to assess abrasive wear on rolling discs. In addition and to evaluate the newly developed RIAT test method, a comprehensive laboratory testing programme including the most commonly used abrasivity test methods and the mineral composition were carried out. Relationships between the achieved results from conventional testing and RIAT results have been analysed.

  7. Method for assessment of stormwater treatment facilities - Synthetic road runoff addition including micro-pollutants and tracer.

    Science.gov (United States)

    Cederkvist, Karin; Jensen, Marina B; Holm, Peter E

    2017-08-01

    Stormwater treatment facilities (STFs) are becoming increasingly widespread but knowledge on their performance is limited. This is due to difficulties in obtaining representative samples during storm events and documenting removal of the broad range of contaminants found in stormwater runoff. This paper presents a method to evaluate STFs by addition of synthetic runoff with representative concentrations of contaminant species, including the use of tracer for correction of removal rates for losses not caused by the STF. A list of organic and inorganic contaminant species, including trace elements representative of runoff from roads is suggested, as well as relevant concentration ranges. The method was used for adding contaminants to three different STFs including a curbstone extension with filter soil, a dual porosity filter, and six different permeable pavements. Evaluation of the method showed that it is possible to add a well-defined mixture of contaminants despite different field conditions by having a flexibly system, mixing different stock-solutions on site, and use bromide tracer for correction of outlet concentrations. Bromide recovery ranged from only 12% in one of the permeable pavements to 97% in the dual porosity filter, stressing the importance of including a conservative tracer for correction of contaminant retention values. The method is considered useful in future treatment performance testing of STFs. The observed performance of the STFs is presented in coming papers. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Standard Test Method for Measuring Dose for Use in Linear Accelerator Pulsed Radiation Effects Tests

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers a calorimetric measurement of the total dose delivered in a single pulse of electrons from an electron linear accelerator or a flash X-ray machine (FXR, e-beam mode) used as an ionizing source in radiation-effects testing. The test method is designed for use with pulses of electrons in the energy range from 10 to 50 MeV and is only valid for cases in which both the calorimeter and the test specimen to be irradiated are“thin” compared to the range of these electrons in the materials of which they are constructed. 1.2 The procedure described can be used in those cases in which (1) the dose delivered in a single pulse is 5 Gy (matl) (500 rd (matl)) or greater, or (2) multiple pulses of a lower dose can be delivered in a short time compared to the thermal time constant of the calorimeter. Matl refers to the material of the calorimeter. The minimum dose per pulse that can be acceptably monitored depends on the variables of the particular test, including pulse rate, pulse uniformity...

  9. Examining Method Effect of Synonym and Antonym Test in Verbal Abilities Measure

    Directory of Open Access Journals (Sweden)

    Wahyu Widhiarso

    2015-08-01

    Full Text Available Many researchers have assumed that different methods could be substituted to measure the same attributes in assessment. Various models have been developed to accommodate the amount of variance attributable to the methods but these models application in empirical research is rare. The present study applied one of those models to examine whether method effects were presents in synonym and antonym tests. Study participants were 3,469 applicants to graduate school. The instrument used was the Graduate Academic Potential Test (PAPS, which includes synonym and antonym questions to measure verbal abilities. Our analysis showed that measurement models that using correlated trait–correlated methods minus one, CT-C(M–1, that separated trait and method effect into distinct latent constructs yielded slightly better values for multiple goodness-of-fit indices than one factor model. However, either for the synonym or antonym items, the proportion of variance accounted for by the method is smaller than trait variance. The correlation between factor scores of both methods is high (r = 0.994. These findings confirm that synonym and antonym tests represent the same attribute so that both tests cannot be treated as two unique methods for measuring verbal ability.

  10. Examining Method Effect of Synonym and Antonym Test in Verbal Abilities Measure.

    Science.gov (United States)

    Widhiarso, Wahyu; Haryanta

    2015-08-01

    Many researchers have assumed that different methods could be substituted to measure the same attributes in assessment. Various models have been developed to accommodate the amount of variance attributable to the methods but these models application in empirical research is rare. The present study applied one of those models to examine whether method effects were presents in synonym and antonym tests. Study participants were 3,469 applicants to graduate school. The instrument used was the Graduate Academic Potential Test (PAPS), which includes synonym and antonym questions to measure verbal abilities. Our analysis showed that measurement models that using correlated trait-correlated methods minus one, CT-C(M-1), that separated trait and method effect into distinct latent constructs yielded slightly better values for multiple goodness-of-fit indices than one factor model. However, either for the synonym or antonym items, the proportion of variance accounted for by the method is smaller than trait variance. The correlation between factor scores of both methods is high (r = 0.994). These findings confirm that synonym and antonym tests represent the same attribute so that both tests cannot be treated as two unique methods for measuring verbal ability.

  11. Dissolution testing of intermediary products in uranium dioxide production by the sol-gel method

    International Nuclear Information System (INIS)

    Melichar, F.; Landspersky, H.; Urbanek, V.

    1979-01-01

    A method was developed of dissolving polyuranates and uranium dioxides in sulphuric acid and in carbonate solutions for testing intermediate products in the sol-gel process preparation of uranium dioxide. A detailed granulometric analysis of spherical particle dispersion was included as part of the tests. Two different production methods were used for the two types of studied materials. The test results show that the test method is suitable for determining temperature sensitivity of the materials to dissolution reaction. The geometrical distribution of impurities in the spherical particles can be determined from the dissolution kinetics. The method allows the determination of the effect of carbon from impurities on the process of uranium dioxide leaching and is thus applicable for testing materials prepared by the sol-gel method. (Z.M.)

  12. Standard test method for wear testing with a pin-on-disk apparatus

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers a laboratory procedure for determining the wear of materials during sliding using a pin-on-disk apparatus. Materials are tested in pairs under nominally non-abrasive conditions. The principal areas of experimental attention in using this type of apparatus to measure wear are described. The coefficient of friction may also be determined. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  13. A Teaching Method on Basic Chemistry for Freshman (II) : Teaching Method with Pre-test and Post-test

    OpenAIRE

    立木, 次郎; 武井, 庚二

    2004-01-01

    This report deals with review of a teaching method on basic chemistry for freshman in this first semester. We tried to review this teaching method with pre-test and post-test by means of the official and private questionnaires. Several hints and thoughts on teaching skills are obtained from this analysis.

  14. Accuracy, Precision, Ease-Of-Use, and Cost of Methods to Test Ebola-Relevant Chlorine Solutions.

    Directory of Open Access Journals (Sweden)

    Emma Wells

    Full Text Available To prevent transmission in Ebola Virus Disease (EVD outbreaks, it is recommended to disinfect living things (hands and people with 0.05% chlorine solution and non-living things (surfaces, personal protective equipment, dead bodies with 0.5% chlorine solution. In the current West African EVD outbreak, these solutions (manufactured from calcium hypochlorite (HTH, sodium dichloroisocyanurate (NaDCC, and sodium hypochlorite (NaOCl have been widely used in both Ebola Treatment Unit and community settings. To ensure solution quality, testing is necessary, however test method appropriateness for these Ebola-relevant concentrations has not previously been evaluated. We identified fourteen commercially-available methods to test Ebola-relevant chlorine solution concentrations, including two titration methods, four DPD dilution methods, and six test strips. We assessed these methods by: 1 determining accuracy and precision by measuring in quintuplicate five different 0.05% and 0.5% chlorine solutions manufactured from NaDCC, HTH, and NaOCl; 2 conducting volunteer testing to assess ease-of-use; and, 3 determining costs. Accuracy was greatest in titration methods (reference-12.4% error compared to reference method, then DPD dilution methods (2.4-19% error, then test strips (5.2-48% error; precision followed this same trend. Two methods had an accuracy of <10% error across all five chlorine solutions with good precision: Hach digital titration for 0.05% and 0.5% solutions (recommended for contexts with trained personnel and financial resources, and Serim test strips for 0.05% solutions (recommended for contexts where rapid, inexpensive, and low-training burden testing is needed. Measurement error from test methods not including pH adjustment varied significantly across the five chlorine solutions, which had pH values 5-11. Volunteers found test strip easiest and titration hardest; costs per 100 tests were $14-37 for test strips and $33-609 for titration

  15. Valid methods: the quality assurance of test method development, validation, approval, and transfer for veterinary testing laboratories.

    Science.gov (United States)

    Wiegers, Ann L

    2003-07-01

    Third-party accreditation is a valuable tool to demonstrate a laboratory's competence to conduct testing. Accreditation, internationally and in the United States, has been discussed previously. However, accreditation is only I part of establishing data credibility. A validated test method is the first component of a valid measurement system. Validation is defined as confirmation by examination and the provision of objective evidence that the particular requirements for a specific intended use are fulfilled. The international and national standard ISO/IEC 17025 recognizes the importance of validated methods and requires that laboratory-developed methods or methods adopted by the laboratory be appropriate for the intended use. Validated methods are therefore required and their use agreed to by the client (i.e., end users of the test results such as veterinarians, animal health programs, and owners). ISO/IEC 17025 also requires that the introduction of methods developed by the laboratory for its own use be a planned activity conducted by qualified personnel with adequate resources. This article discusses considerations and recommendations for the conduct of veterinary diagnostic test method development, validation, evaluation, approval, and transfer to the user laboratory in the ISO/IEC 17025 environment. These recommendations are based on those of nationally and internationally accepted standards and guidelines, as well as those of reputable and experienced technical bodies. They are also based on the author's experience in the evaluation of method development and transfer projects, validation data, and the implementation of quality management systems in the area of method development.

  16. Standard test methods for the strong-base resins used in the recovery of uranium

    International Nuclear Information System (INIS)

    Ford, M.A.; Lombaard, L.R.

    1986-01-01

    There are no detailed specifications for the strong-base ion-exchange resins used in continuous ion-exchange plants, and it was considered that a very useful purpose would be served by the publication of a series of standard laboratory tests on which such specifications could be based. This report describes test methods that are relevant to the ion-exchange recovery of uranium. They include tests of the physical properties of strong-base resins (relative density, particle-size distribution, and moisture content) and of their chemical properties (theoretical capacity, equilibrium capacity, kinetics of loading and elution). Included are several supporting procedures that are used in conjunction with these methods

  17. Standard test methods for performance characteristics of metallic bonded resistance strain gages

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1992-01-01

    1.1 The purpose of this standard is to provide uniform test methods for the determination of strain gauge performance characteristics. Suggested testing equipment designs are included. 1.2 Test Methods E 251 describes methods and procedures for determining five strain gauge parameters: Section Part I—General Requirements 7 Part II—Resistance at a Reference Temperature 8 Part III—Gauge Factor at a Reference Temperature 9 Part IV—Temperature Coefficient of Gauge Factor\t10 Part V—Transverse Sensitivity\t11 Part VI—Thermal Output\t12 1.3 Strain gauges are very sensitive devices with essentially infinite resolution. Their response to strain, however, is low and great care must be exercised in their use. The performance characteristics identified by these test methods must be known to an acceptable accuracy to obtain meaningful results in field applications. 1.3.1 Strain gauge resistance is used to balance instrumentation circuits and to provide a reference value for measurements since all data are...

  18. Standard test method for creep-fatigue crack growth testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the determination of creep-fatigue crack growth properties of nominally homogeneous materials by use of pre-cracked compact type, C(T), test specimens subjected to uniaxial cyclic forces. It concerns fatigue cycling with sufficiently long loading/unloading rates or hold-times, or both, to cause creep deformation at the crack tip and the creep deformation be responsible for enhanced crack growth per loading cycle. It is intended as a guide for creep-fatigue testing performed in support of such activities as materials research and development, mechanical design, process and quality control, product performance, and failure analysis. Therefore, this method requires testing of at least two specimens that yield overlapping crack growth rate data. The cyclic conditions responsible for creep-fatigue deformation and enhanced crack growth vary with material and with temperature for a given material. The effects of environment such as time-dependent oxidation in enhancing the crack growth ra...

  19. Unsteady panel method for complex configurations including wake modeling

    CSIR Research Space (South Africa)

    Van Zyl, Lourens H

    2008-01-01

    Full Text Available implementations of the DLM are however not very versatile in terms of geometries that can be modeled. The ZONA6 code offers a versatile surface panel body model including a separated wake model, but uses a pressure panel method for lifting surfaces. This paper...

  20. The Validation of NAA Method Used as Test Method in Serpong NAA Laboratory

    International Nuclear Information System (INIS)

    Rina-Mulyaningsih, Th.

    2004-01-01

    The Validation Of NAA Method Used As Test Method In Serpong NAA Laboratory. NAA Method is a non standard testing method. The testing laboratory shall validate its using method to ensure and confirm that it is suitable with application. The validation of NAA methods have been done with the parameters of accuracy, precision, repeatability and selectivity. The NIST 1573a Tomato Leaves, NIES 10C Rice flour unpolished and standard elements were used in this testing program. The result of testing with NIST 1573a showed that the elements of Na, Zn, Al and Mn are met from acceptance criteria of accuracy and precision, whereas Co is rejected. The result of testing with NIES 10C showed that Na and Zn elements are met from acceptance criteria of accuracy and precision, but Mn element is rejected. The result of selectivity test showed that the value of quantity is between 0.1-2.5 μg, depend on the elements. (author)

  1. Evaluation of Test Method for Solar Collector Efficiency

    DEFF Research Database (Denmark)

    Fan, Jianhua; Shah, Louise Jivan; Furbo, Simon

    The test method of the standard EN12975-2 (European Committee for Standardization, 2004) is used by European test laboratories to determine the efficiency of solar collectors. In the test methods the mean solar collector fluid temperature in the solar collector, Tm is determined by the approximat...... and the sky temperature. Based on the investigations, recommendations for change of the test methods and test conditions are considered. The investigations are carried out within the NEGST (New Generation of Solar Thermal Systems) project financed by EU.......The test method of the standard EN12975-2 (European Committee for Standardization, 2004) is used by European test laboratories to determine the efficiency of solar collectors. In the test methods the mean solar collector fluid temperature in the solar collector, Tm is determined by the approximated...... equation where Tin is the inlet temperature to the collector and Tout is the outlet temperature from the collector. The specific heat of the solar collector fluid is in the test method as an approximation determined as a constant equal to the specific heat of the solar collector fluid at the temperature Tm...

  2. Thermal test requirements and their verification by different test methods

    International Nuclear Information System (INIS)

    Droste, B.; Wieser, G.; Probst, U.

    1993-01-01

    The paper discusses the parameters influencing the thermal test conditions for type B-packages. Criteria for different test methods (by analytical as well as by experimental means) will be developed. A comparison of experimental results from fuel oil pool and LPG fire tests will be given. (J.P.N.)

  3. An improved brine shrimp larvae lethality microwell test method.

    Science.gov (United States)

    Zhang, Yi; Mu, Jun; Han, Jinyuan; Gu, Xiaojie

    2012-01-01

    This article described an improved brine shrimp larvae lethality microwell test method. A simply designed connecting vessel with alternative photoperiod was used to culture and collect high yield of active Artemia parthenogenetica nauplii for brine shrimp larvae lethality microwell test. Using this method, pure A. parthenogenetica nauplii suspension was easily cultured and harvested with high density about 100-150 larvae per milliliter and the natural mortality was reduced to near zero by elimination of unnecessary artificial disturbance. And its sensitivity was validated by determination of LC(50)-24 h of different reference toxicants including five antitumor agents, two pesticides, three organic pollutants, and four heavy metals salts, most of which exhibited LC(50)-24 h between 0.07 and 58.43 mg/L except for bleomycin and mitomycin C with LC(50)-24 h over 300 mg/L.

  4. Bitumen rubber asphalt mix testing for South African pavement design method

    CSIR Research Space (South Africa)

    Anochie-Boateng, Joseph

    2011-07-01

    Full Text Available The South Africa National Road Agency Ltd has entered into a research and laboratory testing agreement with the CSIR to support the revision of the South African Pavement Design Method (SAPDM). The research includes characterising a bitumen...

  5. Advanced Testing Method for Ground Thermal Conductivity

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xiaobing [ORNL; Clemenzi, Rick [Geothermal Design Center Inc.; Liu, Su [University of Tennessee (UT)

    2017-04-01

    A new method is developed that can quickly and more accurately determine the effective ground thermal conductivity (GTC) based on thermal response test (TRT) results. Ground thermal conductivity is an important parameter for sizing ground heat exchangers (GHEXs) used by geothermal heat pump systems. The conventional GTC test method usually requires a TRT for 48 hours with a very stable electric power supply throughout the entire test. In contrast, the new method reduces the required test time by 40%–60% or more, and it can determine GTC even with an unstable or intermittent power supply. Consequently, it can significantly reduce the cost of GTC testing and increase its use, which will enable optimal design of geothermal heat pump systems. Further, this new method provides more information about the thermal properties of the GHEX and the ground than previous techniques. It can verify the installation quality of GHEXs and has the potential, if developed, to characterize the heterogeneous thermal properties of the ground formation surrounding the GHEXs.

  6. Alternative Test Method for Olefins in Gasoline

    Science.gov (United States)

    This action proposes to allow for an additional alternative test method for olefins in gasoline, ASTM D6550-05. The allowance of this additional alternative test method will provide more flexibility to the regulated industry.

  7. Catalyst support structure, catalyst including the structure, reactor including a catalyst, and methods of forming same

    Science.gov (United States)

    Van Norman, Staci A.; Aston, Victoria J.; Weimer, Alan W.

    2017-05-09

    Structures, catalysts, and reactors suitable for use for a variety of applications, including gas-to-liquid and coal-to-liquid processes and methods of forming the structures, catalysts, and reactors are disclosed. The catalyst material can be deposited onto an inner wall of a microtubular reactor and/or onto porous tungsten support structures using atomic layer deposition techniques.

  8. FY 2016 Status Report: Documentation of All CIRFT Data including Hydride Reorientation Tests (Draft M2)

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jy-An John [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Materials Science and Technology Division; Wang, Hong [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Materials Science and Technology Division; Jiang, Hao [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Materials Science and Technology Division; Yan, Yong [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Materials Science and Technology Division; Bevard, Bruce B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Materials Science and Technology Division; Scaglione, John M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Materials Science and Technology Division

    2016-09-04

    The first portion of this report provides a detailed description of fiscal year (FY) 2015 test result corrections and analysis updates based on FY 2016 updates to the Cyclic Integrated Reversible-Bending Fatigue Tester (CIRFT) program methodology, which is used to evaluate the vibration integrity of spent nuclear fuel (SNF) under normal conditions of transport (NCT). The CIRFT consists of a U-frame test setup and a real-time curvature measurement method. The three-component U-frame setup of the CIRFT has two rigid arms and linkages connecting to a universal testing machine. The curvature SNF rod bending is obtained through a three-point deflection measurement method. Three linear variable differential transformers (LVDTs) are clamped to the side connecting plates of the U-frame and used to capture deformation of the rod. The second portion of this report provides the latest CIRFT data, including data for the hydride reorientation test. The variations in fatigue life are provided in terms of moment, equivalent stress, curvature, and equivalent strain for the tested SNFs. The equivalent stress plot collapsed the data points from all of the SNF samples into a single zone. A detailed examination revealed that, at the same stress level, fatigue lives display a descending order as follows: H. B. Robinson Nuclear Power Station (HBR), LMK, and mixed uranium-plutonium oxide (MOX). Just looking at the strain, LMK fuel has a slightly longer fatigue life than HBR fuel, but the difference is subtle. The third portion of this report provides finite element analysis (FEA) dynamic deformation simulation of SNF assemblies . In a horizontal layout under NCT, the fuel assembly’s skeleton, which is formed by guide tubes and spacer grids, is the primary load bearing apparatus carrying and transferring vibration loads within an SNF assembly. These vibration loads include interaction forces between the SNF assembly and the canister basket walls. Therefore, the integrity of the guide

  9. Assessing Social Isolation: Pilot Testing Different Methods.

    Science.gov (United States)

    Taylor, Harry Owen; Herbers, Stephanie; Talisman, Samuel; Morrow-Howell, Nancy

    2016-04-01

    Social isolation is a significant public health problem among many older adults; however, most of the empirical knowledge about isolation derives from community-based samples. There has been less attention given to isolation in senior housing communities. The objectives of this pilot study were to test two methods to identify socially isolated residents in low-income senior housing and compare findings about the extent of isolation from these two methods. The first method, self-report by residents, included 47 out of 135 residents who completed in-person interviews. To determine self-report isolation, residents completed the Lubben Social Network Scale 6 (LSNS-6). The second method involved a staff member who reported the extent of isolation on all 135 residents via an online survey. Results indicated that 26% of residents who were interviewed were deemed socially isolated by the LSNS-6. Staff members rated 12% of residents as having some or a lot of isolation. In comparing the two methods, staff members rated 2% of interviewed residents as having a lot of isolation. The combination of self-report and staff report could be more informative than just self-report alone, particularly when participation rates are low. However, researchers should be aware of the potential discrepancy between these two methods.

  10. Evaluation of diagnostic tests when there is no gold standard. A review of methods

    NARCIS (Netherlands)

    Rutjes, A. W. S.; Reitsma, J. B.; Coomarasamy, A.; Khan, K. S.; Bossuyt, P. M. M.

    2007-01-01

    OBJECTIVE: To generate a classification of methods to evaluate medical tests when there is no gold standard. METHODS: Multiple search strategies were employed to obtain an overview of the different methods described in the literature, including searches of electronic databases, contacting experts

  11. Comparison of testing methods for particulate filters

    International Nuclear Information System (INIS)

    Ullmann, W.; Przyborowski, S.

    1983-01-01

    Four testing methods for particulate filters were compared by using the test rigs of the National Board of Nuclear Safety and Radiation Protection: 1) Measurement of filter penetration P as a function of particle size d by using a polydisperse NaC1 test aerosol and a scintillation particle counter; 2) Modified sodium flame test for measurement of total filter penetration P for various polydisperse NaC1 test aerosols; 3) Measurement of total filter penetration P for a polydisperse NaC1 test aerosol labelled with short-lived radon daughter products; 4) Measurement of total filter penetration P for a special paraffin oil test aerosol (oil fog test used in FRG according DIN 24 184, test aerosol A). The investigations were carried out on sheets of glass fibre paper (five grades of paper). Detailed information about the four testing methods and the used particle size distributions is given. The different results of the various methods are the base for the discussion of the most important parameters which influence the filter penetration P. The course of the function P=f(d) shows the great influence of the particle size. As expected there was also found a great dependence both from the test aerosol as well as from the principle and the measuring range of the aerosol-measuring device. The differences between the results of the various test methods are greater the lower the penetration. The use of NaCl test aerosol with various particle size distributions gives great differences for the respective penetration values. On the basis of these results and the values given by Dorman conclusions are made about the investigation of particulate filters both for the determination of filter penetration P as well as for the leak test of installed filters

  12. Error response test system and method using test mask variable

    Science.gov (United States)

    Gender, Thomas K. (Inventor)

    2006-01-01

    An error response test system and method with increased functionality and improved performance is provided. The error response test system provides the ability to inject errors into the application under test to test the error response of the application under test in an automated and efficient manner. The error response system injects errors into the application through a test mask variable. The test mask variable is added to the application under test. During normal operation, the test mask variable is set to allow the application under test to operate normally. During testing, the error response test system can change the test mask variable to introduce an error into the application under test. The error response system can then monitor the application under test to determine whether the application has the correct response to the error.

  13. Dynamic fracture testing of ferritic steels using direct current potential drop method

    International Nuclear Information System (INIS)

    Oh, Y. J.; Kim, J. H.; Hwang, I. S.; Park, Y. W.

    2000-01-01

    To apply leak-before-break (LBB) concept to nuclear pipes, the dynamic strain aging of low carbon steel materials has to be considered. For this goal, the J-R tests are needed over a range of temperatures and loading rates, including rapid dynamic loading conditions. In dynamic J-R tests, the unloading compliance method can not be applied and usually the direct current potential drop (DCPD) method has been used. But, even the DCPD method was known to have the problem in defining the crack initiation point due to a potential peak arising in early part of loading of ferromagnetic materials. In this study, potential peaks characteristics were investigated for SA106Gr.C piping steels, and the definition of crack initiation point was made by back tracking from final physical crack length, and it was proposed that this technique could be applied to DCPD method in dynamic loading J-R test

  14. Lessons learned in preparing method 29 filters for compliance testing audits.

    Science.gov (United States)

    Martz, R F; McCartney, J E; Bursey, J T; Riley, C E

    2000-01-01

    Companies conducting compliance testing are required to analyze audit samples at the time they collect and analyze the stack samples if audit samples are available. Eastern Research Group (ERG) provides technical support to the EPA's Emission Measurements Center's Stationary Source Audit Program (SSAP) for developing, preparing, and distributing performance evaluation samples and audit materials. These audit samples are requested via the regulatory Agency and include spiked audit materials for EPA Method 29-Metals Emissions from Stationary Sources, as well as other methods. To provide appropriate audit materials to federal, state, tribal, and local governments, as well as agencies performing environmental activities and conducting emission compliance tests, ERG has recently performed testing of blank filter materials and preparation of spiked filters for EPA Method 29. For sampling stationary sources using an EPA Method 29 sampling train, the use of filters without organic binders containing less than 1.3 microg/in.2 of each of the metals to be measured is required. Risk Assessment testing imposes even stricter requirements for clean filter background levels. Three vendor sources of quartz fiber filters were evaluated for background contamination to ensure that audit samples would be prepared using filters with the lowest metal background levels. A procedure was developed to test new filters, and a cleaning procedure was evaluated to see if a greater level of cleanliness could be achieved using an acid rinse with new filters. Background levels for filters supplied by different vendors and within lots of filters from the same vendor showed a wide variation, confirmed through contact with several analytical laboratories that frequently perform EPA Method 29 analyses. It has been necessary to repeat more than one compliance test because of suspect metals background contamination levels. An acid cleaning step produced improvement in contamination level, but the

  15. New methods of pregnancy testing in adolescent girls.

    Science.gov (United States)

    Saxena, B B

    1981-05-01

    The knowledge and use of newer, more sensitive, and reliable pregnancy tests which are easily accessible and of moderate cost are the 1st steps in the early diagnosis and management of pregnancy, especially in adolescent girls. Accurate diagnosis of pregnancy soon after conception offers the option of abortion by simple, effective, and inexpensive procedures or early initiation of prenatal maternity care. Discussion focuses on the symptoms of pregnancy and the historical development and basis of pregnancy tests as well as the specific types of pregnancy tests. The most familiar sign of pregnancy is the missed period. Other symptoms that provide presumptive evidence of pregnancy include fatigue and lassitude, increased body temperature, and breast fullness or pain. Feelings of nausea, vomiting, and weight gain may appear after 2 weeks. The diagnosis of pregnancy by the detection of the human chorionic gonadotropin was initially described 53 years ago by Selmar Aschheim and Bernhardt Zondek. Improvements in the techniques for the measurement of human chorionic gonadotropin (hCG) have been directly related to the progress in the purification and isolation of hCG and elucidation of the amino acid sequence of the hormone-nonspecific alpha subunit and hormone-specific beta subunit of hCG. The history, physical examination, and pregnancy tests will generally provide sufficient information for a definite diagnosis of pregnancy. The presence of hCG in the urine or blood is the most accurate of all the indications of pregnancy. During the last century, 4 different techniques for the determination of hCG in blood and/or urine have been developed. These include the following and are reviewed in detail: 1) bioassays in intact laboratory animals; 2) immunologic tube or slide methods with heme- or latex-agglutination inhibition, as well as the more recently developed competitive protein binding method such as 3) radioimmunoassay (RIA) for the use of radioisotope labeled hormone

  16. Two micro fatigue test methods for irradiated materials

    International Nuclear Information System (INIS)

    Nunomura, Shigetomo; Noguchi, Shinji; Okamura, Yuichi; Kumai, Shinji

    1993-01-01

    This paper demonstrates two miniature fatigue test methods in response to the requirements of the fusion reactor wall materials development program. It is known that the fatigue strength evaluated by the axial loading test is independent of the specimen size, while that evaluated by the bend test or torsion test is dependent upon the size of specimen. The new type of gripping system for the axial, tension-tension, fatigue testing of TEM disk-size specimens that has been developed is described in this paper. An alignment tool assists in gripping the miniature specimen. The miniature tension-tension fatigue test method seems to provide reliable S-N curves for SUS304 and SUS316L stainless steels. An indentation method has also been developed to determine fatigue properties. A hard steel ball or ceramic ball was used for cyclically loading the specimen, and an S-N curve was subsequently obtained. The merit of this method is primarily simple handling. S-N curves obtained from four materials by this indentation method compared well with those obtained from the rotary bend fatigue test employing a standard-size specimen

  17. HER2 testing in the UK: recommendations for breast and gastric in-situ hybridisation methods

    LENUS (Irish Health Repository)

    Bartlett, J. M. S.

    2011-01-01

    These guidelines supplement existing guidelines on HER2 testing by immunohistochemistry and in-situ hybridisation(ISH) methods in the UK. They provide a specific focus on aspects of guidance relevant to HER2 ISH testing methods, both fluorescent and chromogenic. They are formulated to give advice on methodology, interpretation and quality control for ISH-based testing of HER2 status in common tumour types, including both breast and gastric tumours. The aim is to ensure that all ISH-based testing is accurate, reliable and timely.

  18. Improved ASTM G72 Test Method for Ensuring Adequate Fuel-to-Oxidizer Ratios

    Science.gov (United States)

    Juarez, Alfredo; Harper, Susana Tapia

    2016-01-01

    The ASTM G72/G72M-15 Standard Test Method for Autogenous Ignition Temperature of Liquids and Solids in a High-Pressure Oxygen-Enriched Environment is currently used to evaluate materials for the ignition susceptibility driven by exposure to external heat in an enriched oxygen environment. Testing performed on highly volatile liquids such as cleaning solvents has proven problematic due to inconsistent test results (non-ignitions). Non-ignition results can be misinterpreted as favorable oxygen compatibility, although they are more likely associated with inadequate fuel-to-oxidizer ratios. Forced evaporation during purging and inadequate sample size were identified as two potential causes for inadequate available sample material during testing. In an effort to maintain adequate fuel-to-oxidizer ratios within the reaction vessel during test, several parameters were considered, including sample size, pretest sample chilling, pretest purging, and test pressure. Tests on a variety of solvents exhibiting a range of volatilities are presented in this paper. A proposed improvement to the standard test protocol as a result of this evaluation is also presented. Execution of the final proposed improved test protocol outlines an incremental step method of determining optimal conditions using increased sample sizes while considering test system safety limits. The proposed improved test method increases confidence in results obtained by utilizing the ASTM G72 autogenous ignition temperature test method and can aid in the oxygen compatibility assessment of highly volatile liquids and other conditions that may lead to false non-ignition results.

  19. Falsification Testing of Instrumental Variables Methods for Comparative Effectiveness Research.

    Science.gov (United States)

    Pizer, Steven D

    2016-04-01

    To demonstrate how falsification tests can be used to evaluate instrumental variables methods applicable to a wide variety of comparative effectiveness research questions. Brief conceptual review of instrumental variables and falsification testing principles and techniques accompanied by an empirical application. Sample STATA code related to the empirical application is provided in the Appendix. Comparative long-term risks of sulfonylureas and thiazolidinediones for management of type 2 diabetes. Outcomes include mortality and hospitalization for an ambulatory care-sensitive condition. Prescribing pattern variations are used as instrumental variables. Falsification testing is an easily computed and powerful way to evaluate the validity of the key assumption underlying instrumental variables analysis. If falsification tests are used, instrumental variables techniques can help answer a multitude of important clinical questions. © Health Research and Educational Trust.

  20. Systematic reviews of diagnostic tests in endocrinology: an audit of methods, reporting, and performance.

    Science.gov (United States)

    Spencer-Bonilla, Gabriela; Singh Ospina, Naykky; Rodriguez-Gutierrez, Rene; Brito, Juan P; Iñiguez-Ariza, Nicole; Tamhane, Shrikant; Erwin, Patricia J; Murad, M Hassan; Montori, Victor M

    2017-07-01

    Systematic reviews provide clinicians and policymakers estimates of diagnostic test accuracy and their usefulness in clinical practice. We identified all available systematic reviews of diagnosis in endocrinology, summarized the diagnostic accuracy of the tests included, and assessed the credibility and clinical usefulness of the methods and reporting. We searched Ovid MEDLINE, EMBASE, and Cochrane CENTRAL from inception to December 2015 for systematic reviews and meta-analyses reporting accuracy measures of diagnostic tests in endocrinology. Experienced reviewers independently screened for eligible studies and collected data. We summarized the results, methods, and reporting of the reviews. We performed subgroup analyses to categorize diagnostic tests as most useful based on their accuracy. We identified 84 systematic reviews; half of the tests included were classified as helpful when positive, one-fourth as helpful when negative. Most authors adequately reported how studies were identified and selected and how their trustworthiness (risk of bias) was judged. Only one in three reviews, however, reported an overall judgment about trustworthiness and one in five reported using adequate meta-analytic methods. One in four reported contacting authors for further information and about half included only patients with diagnostic uncertainty. Up to half of the diagnostic endocrine tests in which the likelihood ratio was calculated or provided are likely to be helpful in practice when positive as are one-quarter when negative. Most diagnostic systematic reviews in endocrine lack methodological rigor, protection against bias, and offer limited credibility. Substantial efforts, therefore, seem necessary to improve the quality of diagnostic systematic reviews in endocrinology.

  1. Test equating methods and practices

    CERN Document Server

    Kolen, Michael J

    1995-01-01

    In recent years, many researchers in the psychology and statistical communities have paid increasing attention to test equating as issues of using multiple test forms have arisen and in response to criticisms of traditional testing techniques This book provides a practically oriented introduction to test equating which both discusses the most frequently used equating methodologies and covers many of the practical issues involved The main themes are - the purpose of equating - distinguishing between equating and related methodologies - the importance of test equating to test development and quality control - the differences between equating properties, equating designs, and equating methods - equating error, and the underlying statistical assumptions for equating The authors are acknowledged experts in the field, and the book is based on numerous courses and seminars they have presented As a result, educators, psychometricians, professionals in measurement, statisticians, and students coming to the subject for...

  2. A well test analysis method accounting for pre-test operations

    International Nuclear Information System (INIS)

    Silin, D.B.; Tsang, C.-F.

    2003-01-01

    We propose to use regular monitoring data from a production or injection well for estimating the formation hydraulic properties in the vicinity of the wellbore without interrupting the operations. In our approach, we select a portion of the pumping data over a certain time interval and then derive our conclusions from analysis of these data. A distinctive feature of the proposed approach differing it form conventional methods is in the introduction of an additional parameter, an effective pre-test pumping rate. The additional parameter is derived based on a rigorous asymptotic analysis of the flow model. Thus, we account for the non-uniform pressure distribution at the beginning of testing time interval caused by pre-test operations at the well. By synthetic and field examples, we demonstrate that deviation of the matching curve from the data that is usually attributed to skin and wellbore storage effects, can also be interpreted through this new parameter. Moreover, with our method, the data curve is matched equally well and the results of the analysis remain stable when the analyzed data interval is perturbed, whereas traditional methods are sensitive to the choice of the data interval. A special efficient minimization procedure has been developed for searching the best fitting parameters. We enhanced our analysis above with a procedure of estimating ambient reservoir pressure and dimensionless wellbore radius. The methods reported here have been implemented in code ODA (Operations Data Analysis). A beta version of the code is available for free testing and evaluation to interested parties

  3. Standard Test Methods for Measurement of Electrical Performance and Spectral Response of Nonconcentrator Multijunction Photovoltaic Cells and Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 These test methods provide special techniques needed to determine the electrical performance and spectral response of two-terminal, multijunction photovoltaic (PV) devices, both cell and modules. 1.2 These test methods are modifications and extensions of the procedures for single-junction devices defined by Test Methods E948, E1021, and E1036. 1.3 These test methods do not include temperature and irradiance corrections for spectral response and current-voltage (I-V) measurements. Procedures for such corrections are available in Test Methods E948, E1021, and E1036. 1.4 These test methods may be applied to cells and modules intended for concentrator applications. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and ...

  4. Standard Test Method for Oxyacetylene Ablation Testing of Thermal Insulation Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers the screening of ablative materials to determine the relative thermal insulation effectiveness when tested as a flat panel in an environment of a steady flow of hot gas provided by an oxyacetylene burner. 1.2 This test method should be used to measure and describe the properties of materials, products, or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard of materials, products, or assemblies under actual fire conditions. However, results of this test method may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limi...

  5. Using a fuzzy comprehensive evaluation method to determine product usability: A test case.

    Science.gov (United States)

    Zhou, Ronggang; Chan, Alan H S

    2017-01-01

    In order to take into account the inherent uncertainties during product usability evaluation, Zhou and Chan [1] proposed a comprehensive method of usability evaluation for products by combining the analytic hierarchy process (AHP) and fuzzy evaluation methods for synthesizing performance data and subjective response data. This method was designed to provide an integrated framework combining the inevitable vague judgments from the multiple stages of the product evaluation process. In order to illustrate the effectiveness of the model, this study used a summative usability test case to assess the application and strength of the general fuzzy usability framework. To test the proposed fuzzy usability evaluation framework [1], a standard summative usability test was conducted to benchmark the overall usability of a specific network management software. Based on the test data, the fuzzy method was applied to incorporate both the usability scores and uncertainties involved in the multiple components of the evaluation. Then, with Monte Carlo simulation procedures, confidence intervals were used to compare the reliabilities among the fuzzy approach and two typical conventional methods combining metrics based on percentages. This case study showed that the fuzzy evaluation technique can be applied successfully for combining summative usability testing data to achieve an overall usability quality for the network software evaluated. Greater differences of confidence interval widths between the method of averaging equally percentage and weighted evaluation method, including the method of weighted percentage averages, verified the strength of the fuzzy method.

  6. MODERN METHODS OF FOOD INTOLERANCE TESTING

    Directory of Open Access Journals (Sweden)

    M. Yu. Rosensteyn

    2016-01-01

    Full Text Available Аn analytical review of modern methods of food intolerance diagnostics based on interpretation of markers used in the various tests is рresented. It is shown that tests based on observation of the reaction of specific antibodies of the immune system to food antigens tested, are the most accurate, reliable and representative for the diagnosis of food intolerance.

  7. Force measuring valve assemblies, systems including such valve assemblies and related methods

    Science.gov (United States)

    DeWall, Kevin George [Pocatello, ID; Garcia, Humberto Enrique [Idaho Falls, ID; McKellar, Michael George [Idaho Falls, ID

    2012-04-17

    Methods of evaluating a fluid condition may include stroking a valve member and measuring a force acting on the valve member during the stroke. Methods of evaluating a fluid condition may include measuring a force acting on a valve member in the presence of fluid flow over a period of time and evaluating at least one of the frequency of changes in the measured force over the period of time and the magnitude of the changes in the measured force over the period of time to identify the presence of an anomaly in a fluid flow and, optionally, its estimated location. Methods of evaluating a valve condition may include directing a fluid flow through a valve while stroking a valve member, measuring a force acting on the valve member during the stroke, and comparing the measured force to a reference force. Valve assemblies and related systems are also disclosed.

  8. A comparative study of three cytotoxicity test methods for nanomaterials using sodium lauryl sulfate.

    Science.gov (United States)

    Kwon, Jae-Sung; Kim, Kwang-Mahn; Kim, Kyoung-Nam

    2014-10-01

    The biocompatibility evaluation of nanomaterials is essential for their medical diagnostic and therapeutic usage, where a cytotoxicity test is the simplest form of biocompatibility evaluation. Three methods have been commonly used in previous studies for the cytotoxicity testing of nanomaterials: trypan blue exclusion, colorimetric assay using water soluble tetrazolium (WST), and imaging under a microscope following calcein AM/ethidium homodimer-1 staining. However, there has yet to be a study to compare each method. Therefore, in this study three methods were compared using the standard reference material of sodium lauryl sulfate (SLS). Each method of the cytotoxicity test was carried out using mouse fibroblasts of L-929 exposed to different concentrations of SLS. Compared to the gold standard trypan blue exclusion test, both colorimetric assay using water soluble tetrazolium (WST) and imaging under microscope with calcein AM/ethidium homodimer-1 staining showed results that were not statistically different. Also, each method exhibited various advantages and disadvantages, which included the need of equipment, time taken for the experiment, and provision of additional information such as cell morphology. Therefore, this study concludes that all three methods of cytotoxicity testing may be valid, though careful consideration will be needed when selecting tests with regard to time, finances, and the amount of information required by the researcher(s).

  9. On sine dwell or broadband methods for modal testing

    Science.gov (United States)

    Chen, Jay-Chung; Wada, Ben K.

    1987-01-01

    For large, complex spacecraft structural systems, the objectives of the modal test are outlined. Based on these objectives, the comparison criteria for the modal test methods, namely, the broadband excitation and the sine dwell methods are established. Using the Galileo spacecraft modal test and the Centaur G Prime upper stage vehicle modal test as examples, the relative advantages or disadvantages of each method are examined. The usefulness or shortcoming of the methods are given from a practicing engineer's view point.

  10. Methods Used in Economic Evaluations of Chronic Kidney Disease Testing — A Systematic Review

    Science.gov (United States)

    Sutton, Andrew J.; Breheny, Katie; Deeks, Jon; Khunti, Kamlesh; Sharpe, Claire; Ottridge, Ryan S.; Stevens, Paul E.; Cockwell, Paul; Kalra, Philp A.; Lamb, Edmund J.

    2015-01-01

    Background The prevalence of chronic kidney disease (CKD) is high in general populations around the world. Targeted testing and screening for CKD are often conducted to help identify individuals that may benefit from treatment to ameliorate or prevent their disease progression. Aims This systematic review examines the methods used in economic evaluations of testing and screening in CKD, with a particular focus on whether test accuracy has been considered, and how analysis has incorporated issues that may be important to the patient, such as the impact of testing on quality of life and the costs they incur. Methods Articles that described model-based economic evaluations of patient testing interventions focused on CKD were identified through the searching of electronic databases and the hand searching of the bibliographies of the included studies. Results The initial electronic searches identified 2,671 papers of which 21 were included in the final review. Eighteen studies focused on proteinuria, three evaluated glomerular filtration rate testing and one included both tests. The full impact of inaccurate test results was frequently not considered in economic evaluations in this setting as a societal perspective was rarely adopted. The impact of false positive tests on patients in terms of the costs incurred in re-attending for repeat testing, and the anxiety associated with a positive test was almost always overlooked. In one study where the impact of a false positive test on patient quality of life was examined in sensitivity analysis, it had a significant impact on the conclusions drawn from the model. Conclusion Future economic evaluations of kidney function testing should examine testing and monitoring pathways from the perspective of patients, to ensure that issues that are important to patients, such as the possibility of inaccurate test results, are properly considered in the analysis. PMID:26465773

  11. Analysis of Within-Test Variability of Non-Destructive Test Methods to Evaluate Compressive Strength of Normal Vibrated and Self-Compacting Concretes

    Science.gov (United States)

    Nepomuceno, Miguel C. S.; Lopes, Sérgio M. R.

    2017-10-01

    Non-destructive tests (NDT) have been used in the last decades for the assessment of in-situ quality and integrity of concrete elements. An important step in the application of NDT methods concerns to the interpretation and validation of the test results. In general, interpretation of NDT results should involve three distinct phases leading to the development of conclusions: processing of collected data, analysis of within-test variability and quantitative evaluation of property under investigation. The analysis of within-test variability can provide valuable information, since this can be compared with that of within-test variability associated with the NDT method in use, either to provide a measure of the quality control or to detect the presence of abnormal circumstances during the in-situ application. This paper reports the analysis of the experimental results of within-test variability of NDT obtained for normal vibrated concrete and self-compacting concrete. The NDT reported includes the surface hardness test, ultrasonic pulse velocity test, penetration resistance test, pull-off test, pull-out test and maturity test. The obtained results are discussed and conclusions are presented.

  12. Methods for testing transport models

    International Nuclear Information System (INIS)

    Singer, C.; Cox, D.

    1991-01-01

    Substantial progress has been made over the past year on six aspects of the work supported by this grant. As a result, we have in hand for the first time a fairly complete set of transport models and improved statistical methods for testing them against large databases. We also have initial results of such tests. These results indicate that careful application of presently available transport theories can reasonably well produce a remarkably wide variety of tokamak data

  13. A Proposal for a Methodology to Develop a Cyber-Attack Penetration Test Scenario Including NPPs Safety

    Energy Technology Data Exchange (ETDEWEB)

    Lee, In Hyo [KAIST, Daejeon (Korea, Republic of); Son, Han Seong [Joongbu Univ., Geumsan (Korea, Republic of); Kim, Si Won [Korea Institute of Nuclear Nonproliferation and Control, Daejeon (Korea, Republic of); Kang, Hyun Gook [Rensselaer Polytechnic Institute, Troy (United States)

    2016-10-15

    Penetration test is a method to evaluate the cyber security of NPPs; so, this approach was performed in some studies. Because they focused on vulnerability finding or test bed construction, scenario based approach was not performed. However, to test the cyber security of NPPs, a proper test scenario should be needed. Ahn et al. developed cyber-attack scenarios but those scenarios couldn't be applied in penetration test because they developed the scenarios based on past incidents of NPPs induced by cyber-attack. That is, those scenarios only covered scenarios which were happened before; so, they couldn't cover other various scenarios and couldn't reflect them into a penetration test. In this study, a method to develop a cyber-attack penetration test scenario of NPPs especially focused on safety point of view is suggested. To evaluate the cyber security of NPPs, penetration test can be a possible way. In this study, a method to develop a penetration test scenario was explained. Especially, the goal of hacker was focused on nuclear fuel integrity deterioration. So, in the methodology, Level 1 PSA results were utilized to reflect plant safety into the security. From the PSA results, basic event was post processed and possible cyber-attacks were reviewed with vulnerabilities of digital control system.

  14. A Proposal for a Methodology to Develop a Cyber-Attack Penetration Test Scenario Including NPPs Safety

    International Nuclear Information System (INIS)

    Lee, In Hyo; Son, Han Seong; Kim, Si Won; Kang, Hyun Gook

    2016-01-01

    Penetration test is a method to evaluate the cyber security of NPPs; so, this approach was performed in some studies. Because they focused on vulnerability finding or test bed construction, scenario based approach was not performed. However, to test the cyber security of NPPs, a proper test scenario should be needed. Ahn et al. developed cyber-attack scenarios but those scenarios couldn't be applied in penetration test because they developed the scenarios based on past incidents of NPPs induced by cyber-attack. That is, those scenarios only covered scenarios which were happened before; so, they couldn't cover other various scenarios and couldn't reflect them into a penetration test. In this study, a method to develop a cyber-attack penetration test scenario of NPPs especially focused on safety point of view is suggested. To evaluate the cyber security of NPPs, penetration test can be a possible way. In this study, a method to develop a penetration test scenario was explained. Especially, the goal of hacker was focused on nuclear fuel integrity deterioration. So, in the methodology, Level 1 PSA results were utilized to reflect plant safety into the security. From the PSA results, basic event was post processed and possible cyber-attacks were reviewed with vulnerabilities of digital control system

  15. Fluorescent penetration crack testing method

    International Nuclear Information System (INIS)

    Roth, A.

    1979-01-01

    The same cleaning, penetration, washing, development and evaluation agents are used in this method as for known methods. In order to accelerate or shorten the testing, the drying process is performed only to optical dryness of the material surface by blowing on it with pressurized air, the development by simple pressing into or dusting of the material with the developer and the temperature of the washing water is selected within room temperature range. (RW) [de

  16. Improved sensitivity testing of explosives using transformed Up-Down methods

    International Nuclear Information System (INIS)

    Brown, Geoffrey W

    2014-01-01

    Sensitivity tests provide data that help establish guidelines for the safe handling of explosives. Any sensitivity test is based on assumptions to simplify the method or reduce the number of individual sample evaluations. Two common assumptions that are not typically checked after testing are 1) explosive response follows a normal distribution as a function of the applied stimulus levels and 2) the chosen test level spacing is close to the standard deviation of the explosive response function (for Bruceton Up-Down testing for example). These assumptions and other limitations of traditional explosive sensitivity testing can be addressed using Transformed Up-Down (TUD) test methods. TUD methods have been developed extensively for psychometric testing over the past 50 years and generally use multiple tests at a given level to determine how to adjust the applied stimulus. In the context of explosive sensitivity we can use TUD methods that concentrate testing around useful probability levels. Here, these methods are explained and compared to Bruceton Up-Down testing using computer simulation. The results show that the TUD methods are more useful for many cases but that they do require more tests as a consequence. For non-normal distributions, however, the TUD methods may be the only accurate assessment method.

  17. In Silico Toxicology – Non-Testing Methods

    Science.gov (United States)

    Raunio, Hannu

    2011-01-01

    In silico toxicology in its broadest sense means “anything that we can do with a computer in toxicology.” Many different types of in silico methods have been developed to characterize and predict toxic outcomes in humans and environment. The term non-testing methods denote grouping approaches, structure–activity relationship, and expert systems. These methods are already used for regulatory purposes and it is anticipated that their role will be much more prominent in the near future. This Perspective will delineate the basic principles of non-testing methods and evaluate their role in current and future risk assessment of chemical compounds. PMID:21772821

  18. Standard Test Method for Electrical Performance of Photovoltaic Cells Using Reference Cells Under Simulated Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of the electrical performance of a photovoltaic cell under simulated sunlight by means of a calibrated reference cell procedure. 1.2 Electrical performance measurements are reported with respect to a select set of standard reporting conditions (SRC) (see Table 1) or to user-specified conditions. 1.2.1 The SRC or user-specified conditions include the cell temperature, the total irradiance, and the reference spectral irradiance distribution. 1.3 This test method is applicable only to photovoltaic cells with a linear response over the range of interest. 1.4 The cell parameters determined by this test method apply only at the time of test, and imply no past or future performance level. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this s...

  19. Standard test method for measurement of web/roller friction characteristics

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This test method covers the simulation of a roller/web transport tribosystem and the measurement of the static and kinetic coefficient of friction of the web/roller couple when sliding occurs between the two. The objective of this test method is to provide users with web/roller friction information that can be used for process control, design calculations, and for any other function where web/roller friction needs to be known. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  20. Composite materials and bodies including silicon carbide and titanium diboride and methods of forming same

    Science.gov (United States)

    Lillo, Thomas M.; Chu, Henry S.; Harrison, William M.; Bailey, Derek

    2013-01-22

    Methods of forming composite materials include coating particles of titanium dioxide with a substance including boron (e.g., boron carbide) and a substance including carbon, and reacting the titanium dioxide with the substance including boron and the substance including carbon to form titanium diboride. The methods may be used to form ceramic composite bodies and materials, such as, for example, a ceramic composite body or material including silicon carbide and titanium diboride. Such bodies and materials may be used as armor bodies and armor materials. Such methods may include forming a green body and sintering the green body to a desirable final density. Green bodies formed in accordance with such methods may include particles comprising titanium dioxide and a coating at least partially covering exterior surfaces thereof, the coating comprising a substance including boron (e.g., boron carbide) and a substance including carbon.

  1. Reduction Methods for Real-time Simulations in Hybrid Testing

    DEFF Research Database (Denmark)

    Andersen, Sebastian

    2016-01-01

    Hybrid testing constitutes a cost-effective experimental full scale testing method. The method was introduced in the 1960's by Japanese researchers, as an alternative to conventional full scale testing and small scale material testing, such as shake table tests. The principle of the method...... is performed on a glass fibre reinforced polymer composite box girder. The test serves as a pilot test for prospective real-time tests on a wind turbine blade. The Taylor basis is implemented in the test, used to perform the numerical simulations. Despite of a number of introduced errors in the real...... is to divide a structure into a physical substructure and a numerical substructure, and couple these in a test. If the test is conducted in real-time it is referred to as real time hybrid testing. The hybrid testing concept has developed significantly since its introduction in the 1960', both with respect...

  2. Test Method for Spalling of Fire Exposed Concrete

    DEFF Research Database (Denmark)

    Hertz, Kristian Dahl; Sørensen, Lars Schiøtt

    2005-01-01

    A new material test method is presented for determining whether or not an actual concrete may suffer from explosive spalling at a specified moisture level. The method takes into account the effect of stresses from hindered thermal expansion at the fire-exposed surface. Cylinders are used, which...... in many countries serve as standard specimens for testing the compressive strength. Consequently, the method is quick, cheap and easy to use in comparison to the alternative of testing full-scale or semi full-scale structures with correct humidity, load and boundary conditions. A number of concretes have...

  3. Initiation devices, initiation systems including initiation devices and related methods

    Energy Technology Data Exchange (ETDEWEB)

    Daniels, Michael A.; Condit, Reston A.; Rasmussen, Nikki; Wallace, Ronald S.

    2018-04-10

    Initiation devices may include at least one substrate, an initiation element positioned on a first side of the at least one substrate, and a spark gap electrically coupled to the initiation element and positioned on a second side of the at least one substrate. Initiation devices may include a plurality of substrates where at least one substrate of the plurality of substrates is electrically connected to at least one adjacent substrate of the plurality of substrates with at least one via extending through the at least one substrate. Initiation systems may include such initiation devices. Methods of igniting energetic materials include passing a current through a spark gap formed on at least one substrate of the initiation device, passing the current through at least one via formed through the at least one substrate, and passing the current through an explosive bridge wire of the initiation device.

  4. Evaluation of field test kits including immunoassays for the detection of contaminants in soil and water

    International Nuclear Information System (INIS)

    Waters, L.C.; Smith, R.R.; Counts, R.W.; Stewart, J.H.; Jenkins, R.A.

    1993-01-01

    Effective field test methods are needed for hazardous waste site characterization and remediation. Useful field methods should be rapid, analyte-specific, cost-effective and accurate in the concentration range at which the analyte is regulated. In this study, field test kits for polychlorinated biphenyls (PCBs), mercury, lead and nitrate were evaluated with reference to these criteria. PCBs and mercury, in soils, were analyzed by immunoassay. Ionic lead and nitrate, in water, were measured chemically using test strips. Except for lead, each analyte was measured in both spiked and actual field samples. Twenty to 40 samples per day can be analyzed with the immunoassays and even more with the strip tests. The sensitivity of the immunoassays is in the 1-3 ppM range. Nitrate was consistently detected at ≥5 ppM; lead ions at ≥20 ppM. Results obtained using these methods compared favorably with those obtained by standard laboratory methods. In addition to being useful field screening methods, these kits can be used in the laboratory to sort out negative samples and/or to define proper dilutions for positive samples requiring further analysis

  5. 40 CFR Table 3 of Subpart Aaaaaaa... - Test Methods

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 14 2010-07-01 2010-07-01 false Test Methods 3 Table 3 of Subpart..., Subpt. AAAAAAA, Table 3 Table 3 of Subpart AAAAAAA of Part 63—Test Methods For * * * You must use * * * 1. Selecting the sampling locations a and the number of traverse points EPA test method 1 or 1A in...

  6. Standard Test Method for Application and Analysis of Solid State Track Recorder (SSTR) Monitors for Reactor Surveillance, E706(IIIB)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This test method describes the use of solid-state track recorders (SSTRs) for neutron dosimetry in light-water reactor (LWR) applications. These applications extend from low neutron fluence to high neutron fluence, including high power pressure vessel surveillance and test reactor irradiations as well as low power benchmark field measurement. (1) This test method replaces Method E 418. This test method is more detailed and special attention is given to the use of state-of-the-art manual and automated track counting methods to attain high absolute accuracies. In-situ dosimetry in actual high fluence-high temperature LWR applications is emphasized. 1.2 This test method includes SSTR analysis by both manual and automated methods. To attain a desired accuracy, the track scanning method selected places limits on the allowable track density. Typically good results are obtained in the range of 5 to 800 000 tracks/cm2 and accurate results at higher track densities have been demonstrated for some cases. (2) Trac...

  7. Test methods and load simulation at roller test stand; Pruefmethoden und Lastsimulation auf Rollenpruefstaenden

    Energy Technology Data Exchange (ETDEWEB)

    Engelmann, Juergen [BMW AG, Muenchen (Germany); Koenig, Manfred [VISPIRON AG, Muenchen (Germany)

    2012-11-01

    The development of vehicles is a time expensive process and requires a worldwide mobility, since the vehicles are tested for different environmental conditions, which only occur in specified regions and within predefined seasonal periods. To become independent of weather conditions and the local and seasonal variation, it is necessary to shift particular tests to a climatic wind tunnel. Although this offers an ideal environment for precise and reproducible results, many tests need to be performed in order to acquire knowledge about the differences between real road investigations and wind tunnel experiments. It is the work of Method developers to properly transfer specified road tests to the test facility such that comparable results are obtained. These details will be discussed in the first chapter. An important aspect, within this objective, is the realistic simulation of drive resistance on the road by dynamometers. Therefore the different forces, contributing to the drive resistance on the road, are determined in order to simulate the realistic load on the vehicle drive train by the electric drive units of the dynamometers. To increase the accuracy of the load simulation, a special feature has been added to the dyno-control. This feature includes the influence of air-density on the drive resistance at a given environmental temperature, pressure and humidity. (orig.)

  8. Comparison of test methods for mould growth in buildings

    DEFF Research Database (Denmark)

    Bonderup, Sirid; Gunnarsen, Lars Bo; Knudsen, Sofie Marie

    2016-01-01

    renovation needs. This is of importance when hidden surface testing would require destructive measures and subsequent renovation. After identifying available methods on the Danish market for assessing mould growth in dwellings, a case study was conducted to test the usefulness of the methods in four......The purpose of this work is to compare a range of test methods and kits for assessing whether a building structure is infested by mould fungi. A further purpose of this work is to evaluate whether air-based methods for sampling fungal emissions provide information qualifying decisions concerning...... methods measure different aspects relating to mould growth and vary in selectivity and precision. The two types of air samples indicated low levels of mould growth, even where the results of the other methods indicated high to moderate growth. With methods based on culture and DNA testing some differences...

  9. 40 CFR Appendix A to Part 63 - Test Methods

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 14 2010-07-01 2010-07-01 false Test Methods A Appendix A to Part 63... to Part 63—Test Methods Method 301—Field Validation of Pollutant Measurement Methods from Various Waste Media 1. Applicability and principle 1.1Applicability. This method, as specified in the applicable...

  10. Experimental method for testing diffraction properties of reflection waveguide holograms.

    Science.gov (United States)

    Xie, Yi; Kang, Ming-Wu; Wang, Bao-Ping

    2014-07-01

    Waveguide holograms' diffraction properties include peak wavelength and diffraction efficiency, which play an important role in determining their display performance. Based on the record and reconstruction theory of reflection waveguide holograms, a novel experimental method for testing diffraction properties is introduced and analyzed in this paper, which uses a plano-convex lens optically contacted to the surface of the substrate plate of the waveguide hologram, so that the diffracted light beam can be easily detected. Then an experiment is implemented. The designed reconstruction wavelength of the test sample is 530 nm, and its diffraction efficiency is 100%. The experimental results are a peak wavelength of 527.7 nm and a diffraction efficiency of 94.1%. It is shown that the tested value corresponds well with the designed value.

  11. Diagnostic Methods of Helicobacter pylori Infection for Epidemiological Studies: Critical Importance of Indirect Test Validation.

    Science.gov (United States)

    Miftahussurur, Muhammad; Yamaoka, Yoshio

    2016-01-01

    Among the methods developed to detect H. pylori infection, determining the gold standard remains debatable, especially for epidemiological studies. Due to the decreasing sensitivity of direct diagnostic tests (histopathology and/or immunohistochemistry [IHC], rapid urease test [RUT], and culture), several indirect tests, including antibody-based tests (serology and urine test), urea breath test (UBT), and stool antigen test (SAT) have been developed to diagnose H. pylori infection. Among the indirect tests, UBT and SAT became the best methods to determine active infection. While antibody-based tests, especially serology, are widely available and relatively sensitive, their specificity is low. Guidelines indicated that no single test can be considered as the gold standard for the diagnosis of H. pylori infection and that one should consider the method's advantages and disadvantages. Based on four epidemiological studies, culture and RUT present a sensitivity of 74.2-90.8% and 83.3-86.9% and a specificity of 97.7-98.8% and 95.1-97.2%, respectively, when using IHC as a gold standard. The sensitivity of serology is quite high, but that of the urine test was lower compared with that of the other methods. Thus, indirect test validation is important although some commercial kits propose universal cut-off values.

  12. ASTM Validates Air Pollution Test Methods

    Science.gov (United States)

    Chemical and Engineering News, 1973

    1973-01-01

    The American Society for Testing and Materials (ASTM) has validated six basic methods for measuring pollutants in ambient air as the first part of its Project Threshold. Aim of the project is to establish nationwide consistency in measuring pollutants; determining precision, accuracy and reproducibility of 35 standard measuring methods. (BL)

  13. Finite test sets development method for test execution of safety critical software

    International Nuclear Information System (INIS)

    Shin, Sung Min; Kim, Hee Eun; Kang, Hyun Gook; Lee, Sung Jiun

    2014-01-01

    The V and V method has been utilized for this safety critical software, while SRGM has difficulties because of lack of failure occurrence data on developing phase. For the safety critical software, however, failure data cannot be gathered after installation in real plant when we consider the severe consequence. Therefore, to complement the V and V method, the test-based method need to be developed. Some studies on test-based reliability quantification method for safety critical software have been conducted in nuclear field. These studies provide useful guidance on generating test sets. An important concept of the guidance is that the test sets represent 'trajectories' (a series of successive values for the input variables of a program that occur during the operation of the software over time) in the space of inputs to the software.. Actually, the inputs to the software depends on the state of plant at that time, and these inputs form a new internal state of the software by changing values of some variables. In other words, internal state of the software at specific timing depends on the history of past inputs. Here the internal state of the software which can be changed by past inputs is named as Context of Software (CoS). In a certain CoS, a software failure occurs when a fault is triggered by some inputs. To cover the failure occurrence mechanism of a software, preceding researches insist that the inputs should be a trajectory form. However, in this approach, there are two critical problems. One is the length of the trajectory input. Input trajectory should long enough to cover failure mechanism, but the enough length is not clear. What is worse, to cover some accident scenario, one set of input should represent dozen hours of successive values. The other problem is number of tests needed. To satisfy a target reliability with reasonable confidence level, very large number of test sets are required. Development of this number of test sets is a herculean

  14. Efficiency Test Method for Electric Vehicle Chargers

    DEFF Research Database (Denmark)

    Kieldsen, Andreas; Thingvad, Andreas; Martinenas, Sergejus

    2016-01-01

    This paper investigates different methods for measuring the charger efficiency of mass produced electric vehicles (EVs), in order to compare the different models. The consumers have low attention to the loss in the charger though the impact on the driving cost is high. It is not a high priority...... different vehicles. A unified method for testing the efficiency of the charger in EVs, without direct access to the component, is presented. The method is validated through extensive tests of the models Renault Zoe, Nissan LEAF and Peugeot iOn. The results show a loss between 15 % and 40 %, which is far...

  15. Standard test method for determining elements in waste streams by inductively coupled plasma-atomic emission spectroscopy

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    This test method covers the determination of trace, minor, and major elements in waste streams by inductively coupled plasma-atomic emission spectroscopy (ICP-AES) following an acid digestion of the specimen. Waste streams from manufacturing processes of nuclear and nonnuclear materials can be analyzed. This test method is applicable to the determination of total metals. Results from this test method can be used to characterize waste received by treatment facilities and to formulate appropriate treatment recipes. The results are also usable to process control within waste treatment facilities. This test method is applicable only to waste streams that contain radioactivity levels which do not require special personnel or environmental protection. A list of the elements determined in waste streams and the corresponding lower reporting limit is included

  16. 40 CFR Table 3 of Subpart Bbbbbbb... - Test Methods

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 14 2010-07-01 2010-07-01 false Test Methods 3 Table 3 of Subpart... 3 Table 3 of Subpart BBBBBBB of Part 63—Test Methods For * * * You must use * * * 1. Selecting the sampling locations a and the number of traverse points EPA test method 1 or 1A in appendix A to part 60. 2...

  17. 26 CFR 1.401(a)(26)-7 - Testing methods.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 5 2010-04-01 2010-04-01 false Testing methods. 1.401(a)(26)-7 Section 1.401(a... (CONTINUED) INCOME TAXES Pension, Profit-Sharing, Stock Bonus Plans, Etc. § 1.401(a)(26)-7 Testing methods... the rules in § 1.401(a)(26)-5. (b) Simplified testing method. A plan is treated as satisfying the...

  18. Helium leak testing methods in nuclear applications

    International Nuclear Information System (INIS)

    Ahmad, Anis

    2004-01-01

    Helium mass-spectrometer leak test is the most sensitive leak test method. It gives very reliable and sensitive test results. In last few years application of helium leak testing has gained more importance due to increased public awareness of safety and environment pollution caused by number of growing chemical and other such industries. Helium leak testing is carried out and specified in most of the critical area applications like nuclear, space, chemical and petrochemical industries

  19. Specific binding-adsorbent assay method and test means

    International Nuclear Information System (INIS)

    1981-01-01

    A description is given of an improved specific binding assay method and test means employing a nonspecific adsorbent for the substance to be determined, particularly hepatitis B surface (HBsub(s)) antigen, in its free state or additionally in the form of its immune complex. The invention is illustrated by 1) the radioimmunoadsorbent assay for HBsub(s) antigen, 2) the radioimmunoadsorbent assay for HBsub(s) antigen in the form of immune complex with antibody, 3) a study of adsorption characteristics of various anion exchange materials for HBsub(s) antigen, 4) the use of hydrophobic adsorbents in a radioimmunoadsorbent assay for HBsub(s) antigen and 5) the radioimmunoadsorbent assay for antibody to HBsub(s) antigen. The advantages of the present method for detecting HBsub(s) antigen compared to previous methods include the manufacturing advantages of eliminating the need for insolubilised anti-HBsub(s) and the advantages of a single incubation step, fewer manipulations, storability of adsorbent materials, increased sensitivity and versatility of detecting HBsub(s) antigen in the form of its immune complex if desired. (U.K.)

  20. Nuclear EMP: stripline test method for measuring transfer impedance

    International Nuclear Information System (INIS)

    Miller, J.S.

    1975-11-01

    A method for measuring the transfer impedance of flat metal joints for frequencies to 100 MHz has been developed which makes use of striplines. The stripline method, which has similarities to the quadraxial method used for cylindrical components, is described and sets of test results are given. The transfer impedance of a simple joint is modeled as a spurious hyperbolic curve, and a close curve fit to transfer impedance test data from various samples is demonstrated for both the stripline and the quadraxial methods. Validity checks of the test data are discussed using the curve model and other criteria. The method was developed for testing riveted joints which form the avionics bays on B-1s. The joints must provide shielding from EMP currents

  1. Alternative method of inservice hydraulic testing of difficult to test pumps

    International Nuclear Information System (INIS)

    Stockton, N.B.; Shangari, S.

    1994-01-01

    The pump test codes require that system resistance be varied until the independent variable (either the pump flow rate or differential pressure) equals its reference value. Variance from this fixed reference value is not specifically allowed. However, the design of many systems makes it impractical to set the independent variable to an exact value. Over a limited range of pump operation about the fixed reference value, linear interpolation between two points of pump operation can be used to accurately determine degradation at the reference value without repeating reference test conditions. This paper presents an overview of possible alternatives for hydraulic testing of pumps and a detailed discussion of the linear interpolation method. The approximation error associated with linear interpolation is analyzed. Methods to quantify and minimize approximation error are presented

  2. Observational constraint on the interacting dark energy models including the Sandage-Loeb test

    Science.gov (United States)

    Zhang, Ming-Jian; Liu, Wen-Biao

    2014-05-01

    Two types of interacting dark energy models are investigated using the type Ia supernova (SNIa), observational data (OHD), cosmic microwave background shift parameter, and the secular Sandage-Loeb (SL) test. In the investigation, we have used two sets of parameter priors including WMAP-9 and Planck 2013. They have shown some interesting differences. We find that the inclusion of SL test can obviously provide a more stringent constraint on the parameters in both models. For the constant coupling model, the interaction term has been improved to be only a half of the original scale on corresponding errors. Comparing with only SNIa and OHD, we find that the inclusion of the SL test almost reduces the best-fit interaction to zero, which indicates that the higher-redshift observation including the SL test is necessary to track the evolution of the interaction. For the varying coupling model, data with the inclusion of the SL test show that the parameter at C.L. in Planck priors is , where the constant is characteristic for the severity of the coincidence problem. This indicates that the coincidence problem will be less severe. We then reconstruct the interaction , and we find that the best-fit interaction is also negative, similar to the constant coupling model. However, for a high redshift, the interaction generally vanishes at infinity. We also find that the phantom-like dark energy with is favored over the CDM model.

  3. 40 CFR 60.1300 - What test methods must I use to stack test?

    Science.gov (United States)

    2010-07-01

    ... to the Administrator for approval under § 60.8(b) to use a reference method with minor changes in... 40 Protection of Environment 6 2010-07-01 2010-07-01 false What test methods must I use to stack test? 60.1300 Section 60.1300 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR...

  4. 40 CFR 76.15 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Test methods and procedures. 76.15 Section 76.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.15 Test methods and procedures. (a) The...

  5. Applications of Automation Methods for Nonlinear Fracture Test Analysis

    Science.gov (United States)

    Allen, Phillip A.; Wells, Douglas N.

    2013-01-01

    Using automated and standardized computer tools to calculate the pertinent test result values has several advantages such as: 1. allowing high-fidelity solutions to complex nonlinear phenomena that would be impractical to express in written equation form, 2. eliminating errors associated with the interpretation and programing of analysis procedures from the text of test standards, 3. lessening the need for expertise in the areas of solid mechanics, fracture mechanics, numerical methods, and/or finite element modeling, to achieve sound results, 4. and providing one computer tool and/or one set of solutions for all users for a more "standardized" answer. In summary, this approach allows a non-expert with rudimentary training to get the best practical solution based on the latest understanding with minimum difficulty.Other existing ASTM standards that cover complicated phenomena use standard computer programs: 1. ASTM C1340/C1340M-10- Standard Practice for Estimation of Heat Gain or Loss Through Ceilings Under Attics Containing Radiant Barriers by Use of a Computer Program 2. ASTM F 2815 - Standard Practice for Chemical Permeation through Protective Clothing Materials: Testing Data Analysis by Use of a Computer Program 3. ASTM E2807 - Standard Specification for 3D Imaging Data Exchange, Version 1.0 The verification, validation, and round-robin processes required of a computer tool closely parallel the methods that are used to ensure the solution validity for equations included in test standard. The use of automated analysis tools allows the creation and practical implementation of advanced fracture mechanics test standards that capture the physics of a nonlinear fracture mechanics problem without adding undue burden or expense to the user. The presented approach forms a bridge between the equation-based fracture testing standards of today and the next generation of standards solving complex problems through analysis automation.

  6. A novel technique for including surface tension in PLIC-VOF methods

    Energy Technology Data Exchange (ETDEWEB)

    Meier, M.; Yadigaroglu, G. [Swiss Federal Institute of Technology, Nuclear Engineering Lab. ETH-Zentrum, CLT, Zurich (Switzerland); Smith, B. [Paul Scherrer Inst. (PSI), Villigen (Switzerland). Lab. for Thermal-Hydraulics

    2002-02-01

    Various versions of Volume-of-Fluid (VOF) methods have been used successfully for the numerical simulation of gas-liquid flows with an explicit tracking of the phase interface. Of these, Piecewise-Linear Interface Construction (PLIC-VOF) appears as a fairly accurate, although somewhat more involved variant. Including effects due to surface tension remains a problem, however. The most prominent methods, Continuum Surface Force (CSF) of Brackbill et al. and the method of Zaleski and co-workers (both referenced later), both induce spurious or 'parasitic' currents, and only moderate accuracy in regards to determining the curvature. We present here a new method to determine curvature accurately using an estimator function, which is tuned with a least-squares-fit against reference data. Furthermore, we show how spurious currents may be drastically reduced using the reconstructed interfaces from the PLIC-VOF method. (authors)

  7. Stopping test of iterative methods for solving PDE

    International Nuclear Information System (INIS)

    Wang Bangrong

    1991-01-01

    In order to assure the accuracy of the numerical solution of the iterative method for solving PDE (partial differential equation), the stopping test is very important. If the coefficient matrix of the system of linear algebraic equations is strictly diagonal dominant or irreducible weakly diagonal dominant, the stopping test formulas of the iterative method for solving PDE is proposed. Several numerical examples are given to illustrate the applications of the stopping test formulas

  8. A robust two-node, 13 moment quadrature method of moments for dilute particle flows including wall bouncing

    Science.gov (United States)

    Sun, Dan; Garmory, Andrew; Page, Gary J.

    2017-02-01

    For flows where the particle number density is low and the Stokes number is relatively high, as found when sand or ice is ingested into aircraft gas turbine engines, streams of particles can cross each other's path or bounce from a solid surface without being influenced by inter-particle collisions. The aim of this work is to develop an Eulerian method to simulate these types of flow. To this end, a two-node quadrature-based moment method using 13 moments is proposed. In the proposed algorithm thirteen moments of particle velocity, including cross-moments of second order, are used to determine the weights and abscissas of the two nodes and to set up the association between the velocity components in each node. Previous Quadrature Method of Moments (QMOM) algorithms either use more than two nodes, leading to increased computational expense, or are shown here to give incorrect results under some circumstances. This method gives the computational efficiency advantages of only needing two particle phase velocity fields whilst ensuring that a correct combination of weights and abscissas is returned for any arbitrary combination of particle trajectories without the need for any further assumptions. Particle crossing and wall bouncing with arbitrary combinations of angles are demonstrated using the method in a two-dimensional scheme. The ability of the scheme to include the presence of drag from a carrier phase is also demonstrated, as is bouncing off surfaces with inelastic collisions. The method is also applied to the Taylor-Green vortex flow test case and is found to give results superior to the existing two-node QMOM method and is in good agreement with results from Lagrangian modelling of this case.

  9. Methods of Usability Testing in Libraries Web Sites

    Directory of Open Access Journals (Sweden)

    Eman Fawzy

    2006-03-01

    Full Text Available A Study about libraries' web sites evaluation, that is the Usability, the study talking about methods of usability testing and define it, and its important in web sites evaluation, then details the methods of usability: questionnaire, core groups, testing experimental model, cards arrangement, and composed evaluation.

  10. Validation of Alternative In Vitro Methods to Animal Testing: Concepts, Challenges, Processes and Tools.

    Science.gov (United States)

    Griesinger, Claudius; Desprez, Bertrand; Coecke, Sandra; Casey, Warren; Zuang, Valérie

    This chapter explores the concepts, processes, tools and challenges relating to the validation of alternative methods for toxicity and safety testing. In general terms, validation is the process of assessing the appropriateness and usefulness of a tool for its intended purpose. Validation is routinely used in various contexts in science, technology, the manufacturing and services sectors. It serves to assess the fitness-for-purpose of devices, systems, software up to entire methodologies. In the area of toxicity testing, validation plays an indispensable role: "alternative approaches" are increasingly replacing animal models as predictive tools and it needs to be demonstrated that these novel methods are fit for purpose. Alternative approaches include in vitro test methods, non-testing approaches such as predictive computer models up to entire testing and assessment strategies composed of method suites, data sources and decision-aiding tools. Data generated with alternative approaches are ultimately used for decision-making on public health and the protection of the environment. It is therefore essential that the underlying methods and methodologies are thoroughly characterised, assessed and transparently documented through validation studies involving impartial actors. Importantly, validation serves as a filter to ensure that only test methods able to produce data that help to address legislative requirements (e.g. EU's REACH legislation) are accepted as official testing tools and, owing to the globalisation of markets, recognised on international level (e.g. through inclusion in OECD test guidelines). Since validation creates a credible and transparent evidence base on test methods, it provides a quality stamp, supporting companies developing and marketing alternative methods and creating considerable business opportunities. Validation of alternative methods is conducted through scientific studies assessing two key hypotheses, reliability and relevance of the

  11. Standard test method for radiochemical determination of uranium isotopes in urine by alpha spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method is applicable to the determination of uranium in urine at levels of detection dependent on sample size, count time, detector background, and tracer yield. It is designed as a screening tool for detection of possible exposure of occupational workers. 1.2 This test method is designed for 50 mL of urine. This test method does not address the sampling protocol or sample preservation methods associated with its use. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  12. Methods for testing of geometrical down-scaled rotor blades

    DEFF Research Database (Denmark)

    Branner, Kim; Berring, Peter

    further developed since then. Structures in composite materials are generally difficult and time consuming to test for fatigue resistance. Therefore, several methods for testing of blades have been developed and exist today. Those methods are presented in [1]. Current experimental test performed on full...

  13. Testing method for ceramic armour and bare ceramic tiles

    NARCIS (Netherlands)

    Carton, E.P.; Roebroeks, G.H.J.J.

    2016-01-01

    TNO developed an alternative, more configuration independent ceramic test method than the Depth-of-Penetration test method. In this alternative test ceramic tiles and ceramic based armour are evaluated as target without a semi-infinite backing layer. An energy approach is chosen to evaluate and rank

  14. Testing method for ceramic armor and bare ceramic tiles

    NARCIS (Netherlands)

    Carton, E.P.; Roebroeks, G.H.J.J.

    2014-01-01

    TNO has developed an alternative, more configuration independent ceramic test method than the standard Depth-of-Penetration test method. In this test ceramic tiles and ceramic based armor are evaluated as target without a semi-infinite backing layer. An energy approach is chosen to evaluate and rank

  15. Comparison of sine dwell and broadband methods for modal testing

    Science.gov (United States)

    Chen, Jay-Chung

    1989-01-01

    The objectives of modal tests for large complex spacecraft structural systems are outlined. The comparison criteria for the modal test methods, namely, the broadband excitation and the sine dwell methods, are established. Using the Galileo spacecraft modal test and the Centaur G Prime upper stage vehicle modal test as examples, the relative advantage or disadvantage of each method is examined. The usefulness or shortcomings of the methods are given from a practical engineering viewpoint.

  16. Standard test method for guided bend test for ductility of welds

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers a guided bend test for the determination of soundness and ductility of welds in ferrous and nonferrous products. Defects, not shown by X rays, may appear in the surface of a specimen when it is subjected to progressive localized overstressing. This guided bend test has been developed primarily for plates and is not intended to be substituted for other methods of bend testing. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. Note 1—For additional information see Terminology E 6, and American Welding Society Standard D 1.1. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  17. PID Testing Method Suitable for Process Control of Solar Cells Mass Production

    Directory of Open Access Journals (Sweden)

    Xianfang Gou

    2015-01-01

    Full Text Available Voltage bias of several hundred volts which are applied between solar cells and module frames may lead to significant power losses, so-called potential-induced degradation (PID, in normal photovoltaic (PV installations system. Modules and minimodules are used to conduct PID test of solar cells. The test procedure is time consuming and of high cost, which cannot be used as process monitoring method during solar cells fabrication. In this paper, three kinds of test including minimodule, Rsh, and V-Q test are conducted on solar cells or wafers with SiNx of different refractive index. All comparisons between test results of Rsh, V-Q, and minimodule tests have shown equal results. It is shown that Rsh test can be used as quality inspection of solar cells and V-Q test of coated wafer can be used as process control of solar cells.

  18. Standardized methods for in-place filter testing

    Energy Technology Data Exchange (ETDEWEB)

    Dykes, M.; Fretthold, J.K.; Slawski, J.

    1997-08-01

    The conference minutes of a US DOE meeting held on in-place filter testing are presented. The purpose of the conference was to transfer technical in-place testing knowledge throughout the DOE complex. Major items discussed included purchase requisitions, in-place testing, instrumentation, and in-place test personnel qualifications and training. Future actions identified by conference attendees centered on establishing complex-wide DOE policies on training, inspection and testing, and filter specifications.

  19. Antimicrobial Testing Methods & Procedures Developed by EPA's Microbiology Laboratory

    Science.gov (United States)

    We develop antimicrobial testing methods and standard operating procedures to measure the effectiveness of hard surface disinfectants against a variety of microorganisms. Find methods and procedures for antimicrobial testing.

  20. Evaluation of clinical methods for peroneal muscle testing.

    Science.gov (United States)

    Sarig-Bahat, Hilla; Krasovsky, Andrei; Sprecher, Elliot

    2013-03-01

    Manual muscle testing of the peroneal muscles is well accepted as a testing method in musculoskeletal physiotherapy for the assessment of the foot and ankle. The peroneus longus and brevis are primary evertors and secondary plantar flexors of the ankle joint. However, some international textbooks describe them as dorsi flexors, when instructing peroneal muscle testing. The identified variability raised a question whether these educational texts are reflected in the clinical field. The purposes of this study were to investigate what are the methods commonly used in the clinical field for peroneal muscle testing and to evaluate their compatibility with functional anatomy. A cross-sectional study was conducted, using an electronic questionnaire sent to 143 Israeli physiotherapists in the musculoskeletal field. The survey questioned on the anatomical location of manual resistance and the combination of motions resisted. Ninety-seven responses were received. The majority (69%) of respondents related correctly to the peronei as evertors, but asserted that resistance should be located over the dorsal aspect of the fifth metatarsus, thereby disregarding the peroneus longus. Moreover, 38% of the respondents described the peronei as dorsi flexors, rather than plantar flexors. Only 2% selected the correct method of resisting plantarflexion and eversion at the base of the first metatarsus. We consider this technique to be the most compatible with the anatomy of the peroneus longus and brevis. The Fisher-Freeman-Halton test indicated that there was a significant relationship between responses on the questions (P = 0.0253, 95% CI 0.0249-0.0257), thus justifying further correspondence analysis. The correspondence analysis found no clustering of the answers that were compatible with anatomical evidence and were applied in the correct technique, but did demonstrate a common error, resisting dorsiflexion rather than plantarflexion, which was in agreement with the described

  1. Well test imaging - a new method for determination of boundaries from well test data

    Energy Technology Data Exchange (ETDEWEB)

    Slevinsky, B.A.

    1997-08-01

    A new method has been developed for analysis of well test data, which allows the direct calculation of the location of arbitrary reservoir boundaries which are detected during a well test. The method is based on elements of ray tracing and information theory, and is centered on the calculation of an instantaneous {open_quote}angle of view{close_quote} of the reservoir boundaries. In the absence of other information, the relative reservoir shape and boundary distances are retrievable in the form of a Diagnostic Image. If other reservoir information, such as 3-D seismic, is available; the full shape and orientation of arbitrary (non-straight line or circular arc) boundaries can be determined in the form of a Reservoir Image. The well test imaging method can be used to greatly enhance the information available from well tests and other geological data, and provides a method to integrate data from multiple disciplines to improve reservoir characterization. This paper covers the derivation of the analytical technique of well test imaging and shows examples of application of the technique to a number of reservoirs.

  2. Standard Test Methods for Constituent Content of Composite Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods determine the constituent content of composite materials by one of two approaches. Method I physically removes the matrix by digestion or ignition by one of seven procedures, leaving the reinforcement essentially unaffected and thus allowing calculation of reinforcement or matrix content (by weight or volume) as well as percent void volume. Method II, applicable only to laminate materials of known fiber areal weight, calculates reinforcement or matrix content (by weight or volume), and the cured ply thickness, based on the measured thickness of the laminate. Method II is not applicable to the measurement of void volume. 1.1.1 These test methods are primarily intended for two-part composite material systems. However, special provisions can be made to extend these test methods to filled material systems with more than two constituents, though not all test results can be determined in every case. 1.1.2 The procedures contained within have been designed to be particularly effective for ce...

  3. An evaluation of the whole effluent toxicity test method

    International Nuclear Information System (INIS)

    Osteen, D.V.

    1999-01-01

    Whole effluent toxicity (WET) testing has become increasingly more important to the Environmental Protection Agency (EPA) and the States in the permitting of wastewater discharges from industry and municipalities. The primary purpose of the WET test is to protect aquatic life by predicting the effect of an effluent on the receiving stream. However, there are both scientific and regulatory concerns that using WET tests to regulate industrial effluents may result in either false positives and/or false negatives. In order to realistically predict the effect of an effluent on the receiving stream, the test should be as representative as possible of the conditions in the receiving stream. Studies (Rand and Petrocelli 1985) suggested several criteria for an ideal aquatic toxicity test organism, one of which is that the organism be indigenous to, or representative of, the ecosystem receiving the effluent. The other component needed in the development of a predictive test is the use of the receiving stream water or similar synthetic water as the control and dilution water in the test method. Use of an indigenous species and receiving water in the test should help reduce the variability in the method and allow the test to predict the effect of the effluent on the receiving stream. The experience with toxicity testing at the Savannah River Site (SRS) has yielded inconclusive data because of the inconsistency and unreliability of the results. The SRS contention is that the WET method in its present form does not adequately mimic actual biological/chemical conditions of the receiving streams and is neither reasonable nor accurate. This paper discusses the rationale for such a position by SRS on toxicity testing in terms of historical permitting requirements, outfall effluent test results, standard test method evaluation, scientific review of alternate test species, and concerns over the test method expressed by other organizations. This paper presents the Savannah River Site

  4. Comments on the sequential probability ratio testing methods

    Energy Technology Data Exchange (ETDEWEB)

    Racz, A. [Hungarian Academy of Sciences, Budapest (Hungary). Central Research Inst. for Physics

    1996-07-01

    In this paper the classical sequential probability ratio testing method (SPRT) is reconsidered. Every individual boundary crossing event of the SPRT is regarded as a new piece of evidence about the problem under hypothesis testing. The Bayes method is applied for belief updating, i.e. integrating these individual decisions. The procedure is recommended to use when the user (1) would like to be informed about the tested hypothesis continuously and (2) would like to achieve his final conclusion with high confidence level. (Author).

  5. Seismic test qualification of electrical equipment - testing methods in use to EDF

    International Nuclear Information System (INIS)

    Fabries, R.

    1981-01-01

    At the beginning, for the 900 MW Power Plant level, the testing method in application used the single axis test by sine beat of 10 cycles according to the specifications of the guide IEEE 344-71. When the french guide UTEC 20-420 came into force we have had to define another testing method (EDF standard: HN20 E52) which utilize the single-axis test either by a sine beat of 5-cycles or by a synthetized time history. We present here the mains criterions allowing to justify: -The single-axis test. The single frequency wave (when the Initial Response Spectrum (IRS) present a narrow band). The use of one sine beat of 5-cycles or one synthetized time history. The need of taking into account the high stress level. This oligocyclic stress fatigue explains why one beat of 5-cycles may be as severe as one time history of 20 seconds (with the same level of strong response spectrum). Then, we conclude that the durating of the testing wave applied to the equipment shall be considered as a relative parameter only. The weight of the SSE tests by respect to the OBE tests. The precautions to take in order to: generate and check accurately the synthetized time history, choice the test frequencies when the sine beat is used. (orig./HP)

  6. From the Kirsch-Kress potential method via the range test to the singular sources method

    International Nuclear Information System (INIS)

    Potthast, R; Schulz, J

    2005-01-01

    We review three reconstruction methods for inverse obstacle scattering problems. We will analyse the relation between the Kirsch-Kress potential method 1986, the range test of Kusiak, Potthast and Sylvester (2003) and the singular sources method of Potthast (2000). In particular, we show that the range test is a logical extension of the Kirsch-Kress method into the category of sampling methods employing the tool of domain sampling. Then we will show how a multi-wave version of the range test can be set up and we will work out its relation to the singular sources method. Numerical examples and demonstrations will be provided

  7. Accelerated Test Method for Corrosion Protective Coatings Project

    Science.gov (United States)

    Falker, John; Zeitlin, Nancy; Calle, Luz

    2015-01-01

    This project seeks to develop a new accelerated corrosion test method that predicts the long-term corrosion protection performance of spaceport structure coatings as accurately and reliably as current long-term atmospheric exposure tests. This new accelerated test method will shorten the time needed to evaluate the corrosion protection performance of coatings for NASA's critical ground support structures. Lifetime prediction for spaceport structure coatings has a 5-year qualification cycle using atmospheric exposure. Current accelerated corrosion tests often provide false positives and negatives for coating performance, do not correlate to atmospheric corrosion exposure results, and do not correlate with atmospheric exposure timescales for lifetime prediction.

  8. Generating and testing methods for consumer-oriented product development

    International Nuclear Information System (INIS)

    2001-10-01

    In order to obtain a good insight into various design methods that can be used by product developers to enable them to develop and test useful domotics products (domotics: intelligent systems for the home), an inventory has been made of the methods used in the Netherlands. The inventory is directed at two categories of methods: (1) Methods of getting better acquainted with the user and/or the problem, and of generating novel solutions: generative methods; and (2) Methods of assessing solutions (through various phases of the designing process): testing methods. The first category of methods concentrates on the designing process. In other words: how can the designer realise as much as possible of the workability of (domotics) products during the designing process? The second category aims at testing a design (in whatever shape: drawing, prototype, functional computer animation, etc.) through its users. These are methods of assessing a design at various stages of the designing process [nl

  9. Latency in Visionic Systems: Test Methods and Requirements

    Science.gov (United States)

    Bailey, Randall E.; Arthur, J. J., III; Williams, Steven P.; Kramer, Lynda J.

    2005-01-01

    A visionics device creates a pictorial representation of the external scene for the pilot. The ultimate objective of these systems may be to electronically generate a form of Visual Meteorological Conditions (VMC) to eliminate weather or time-of-day as an operational constraint and provide enhancement over actual visual conditions where eye-limiting resolution may be a limiting factor. Empirical evidence has shown that the total system delays or latencies including the imaging sensors and display systems, can critically degrade their utility, usability, and acceptability. Definitions and measurement techniques are offered herein as common test and evaluation methods for latency testing in visionics device applications. Based upon available data, very different latency requirements are indicated based upon the piloting task, the role in which the visionics device is used in this task, and the characteristics of the visionics cockpit display device including its resolution, field-of-regard, and field-of-view. The least stringent latency requirements will involve Head-Up Display (HUD) applications, where the visionics imagery provides situational information as a supplement to symbology guidance and command information. Conversely, the visionics system latency requirement for a large field-of-view Head-Worn Display application, providing a Virtual-VMC capability from which the pilot will derive visual guidance, will be the most stringent, having a value as low as 20 msec.

  10. New test and characterization methods for PV modules and cells

    Energy Technology Data Exchange (ETDEWEB)

    Van Aken, B.; Sommeling, P. [ECN Solar Energy, Petten (Netherlands); Scholten, H. [Solland, Heerlen (Netherlands); Muller, J. [Moser-Baer, Eindhoven (Netherlands); Grossiord, N. [Holst Centre, Eindhoven (Netherlands); Smits, C.; Blanco Mantecon, M. [Holland Innovative, Eindhoven (Netherlands); Verheijen, M.; Van Berkum, J. [Philips Innovation Services, Eindhoven (Netherlands)

    2012-08-15

    The results of the project geZONd (shared facility for solar module analysis and reliability testing) are described. The project was set up by Philips, ECN, Holst, Solland, OM and T and Holland Innovative. The partners have shared most of their testing and analysis equipment for PV modules and cells, and together developed new or improved methods (including the necessary application know-how). This enables faster and more efficient innovation projects for each partner, and via commercial exploitation for other interested parties. The project has concentrated on five failure modes: corrosion, delamination, moisture ingress, UV irradiation, and mechanical bending. Test samples represented all main PV technologies: wafer based PV and rigid and flexible thin-film PV. Breakthroughs are in very early detection of corrosion, in quantitative characterization of adhesion, in-situ detection of humidity and oxygen inside modules, and ultra-fast screening of materials on UV stability.

  11. Standard Test Method for Saltwater Pressure Immersion and Temperature Testing of Photovoltaic Modules for Marine Environments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method provides a procedure for determining the ability of photovoltaic modules to withstand repeated immersion or splash exposure by seawater as might be encountered when installed in a marine environment, such as a floating aid-to-navigation. A combined environmental cycling exposure with modules repeatedly submerged in simulated saltwater at varying temperatures and under repetitive pressurization provides an accelerated basis for evaluation of aging effects of a marine environment on module materials and construction. 1.2 This test method defines photovoltaic module test specimens and requirements for positioning modules for test, references suitable methods for determining changes in electrical performance and characteristics, and specifies parameters which must be recorded and reported. 1.3 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method. 1.4 The values stated in SI units are to be ...

  12. Development of standard testing methods for nuclear-waste forms

    International Nuclear Information System (INIS)

    Mendel, J.E.; Nelson, R.D.

    1981-11-01

    Standard test methods for waste package component development and design, safety analyses, and licensing are being developed for the Nuclear Waste Materials Handbook. This paper describes mainly the testing methods for obtaining waste form materials data

  13. Comparative study of fracture mechanical test methods for concrete

    DEFF Research Database (Denmark)

    Østergaard, Lennart; Olesen, John Forbes

    2004-01-01

    and the interpretation, i.e. the analysis needed to extract the stress-crack opening relationship, the fracture energy etc. Experiments are carried out with each test configuration using mature, high performance concrete. The results show that the UTT is a highly complicated test, which only under very well controlled...... circumstances will yield the true fracture mechanical properties. It is also shown that both the three point bending test and the WST are well-suited substitutes for the uniaxial tension test.......This paper describes and compares three different fracture mechanical test methods; the uniaxial tension test (UTT), the three point bending test (TPBT) and the wedge splitting test (WST). Potentials and problems with the test methods will be described with regard to the experiment...

  14. A method for evaluating horizontal well pumping tests.

    Science.gov (United States)

    Langseth, David E; Smyth, Andrew H; May, James

    2004-01-01

    Predicting the future performance of horizontal wells under varying pumping conditions requires estimates of basic aquifer parameters, notably transmissivity and storativity. For vertical wells, there are well-established methods for estimating these parameters, typically based on either the recovery from induced head changes in a well or from the head response in observation wells to pumping in a test well. Comparable aquifer parameter estimation methods for horizontal wells have not been presented in the ground water literature. Formation parameter estimation methods based on measurements of pressure in horizontal wells have been presented in the petroleum industry literature, but these methods have limited applicability for ground water evaluation and are based on pressure measurements in only the horizontal well borehole, rather than in observation wells. This paper presents a simple and versatile method by which pumping test procedures developed for vertical wells can be applied to horizontal well pumping tests. The method presented here uses the principle of superposition to represent the horizontal well as a series of partially penetrating vertical wells. This concept is used to estimate a distance from an observation well at which a vertical well that has the same total pumping rate as the horizontal well will produce the same drawdown as the horizontal well. This equivalent distance may then be associated with an observation well for use in pumping test algorithms and type curves developed for vertical wells. The method is shown to produce good results for confined aquifers and unconfined aquifers in the absence of delayed yield response. For unconfined aquifers, the presence of delayed yield response increases the method error.

  15. Evaluation of methods to leak test sealed radiation sources

    International Nuclear Information System (INIS)

    Arbeau, N.D.; Scott, C.K.

    1987-04-01

    The methods for the leak testing of sealed radiation sources were reviewed. One hundred and thirty-one equipment vendors were surveyed to identify commercially available leak test instruments. The equipment is summarized in tabular form by radiation type and detector type for easy reference. The radiation characteristics of the licensed sources were reviewed and summarized in a format that can be used to select the most suitable detection method. A test kit is proposed for use by inspectors when verifying a licensee's test procedures. The general elements of leak test procedures are discussed

  16. Testing and Validation of the Dynamic Inertia Measurement Method

    Science.gov (United States)

    Chin, Alexander W.; Herrera, Claudia Y.; Spivey, Natalie D.; Fladung, William A.; Cloutier, David

    2015-01-01

    The Dynamic Inertia Measurement (DIM) method uses a ground vibration test setup to determine the mass properties of an object using information from frequency response functions. Most conventional mass properties testing involves using spin tables or pendulum-based swing tests, which for large aerospace vehicles becomes increasingly difficult and time-consuming, and therefore expensive, to perform. The DIM method has been validated on small test articles but has not been successfully proven on large aerospace vehicles. In response, the National Aeronautics and Space Administration Armstrong Flight Research Center (Edwards, California) conducted mass properties testing on an "iron bird" test article that is comparable in mass and scale to a fighter-type aircraft. The simple two-I-beam design of the "iron bird" was selected to ensure accurate analytical mass properties. Traditional swing testing was also performed to compare the level of effort, amount of resources, and quality of data with the DIM method. The DIM test showed favorable results for the center of gravity and moments of inertia; however, the products of inertia showed disagreement with analytical predictions.

  17. Application of the X-in-the-Loop Testing Method in the FCV Hybrid Degree Test

    Directory of Open Access Journals (Sweden)

    Haiyu Gao

    2018-02-01

    Full Text Available With the development of fuel cell vehicle technology, an effective testing method that can be applied to develop and verify the fuel cell vehicle powertrain system is urgently required. This paper presents the X-in-the-Loop (XiL testing method in the fuel cell vehicle (FCV hybrid degree test to resolve the first and key issues for the powertrain system design, and the test process and scenarios were designed. The hybrid degree is redefined into the static hybrid degree for system architecture design and the dynamic hybrid degree for vehicle control strategy design, and an integrated testing platform was introduced and a testing application was implemented by following the designed testing flowchart with two loops. Experimental validations show that the sizing of the FCE (Fuel Cell Engine, battery pack, and traction motor with the powertrain architecture can be determined, the control strategy can be evaluated seamlessly, and a systematic powertrain testing solution can be achieved through the whole development process. This research has developed a new testing platform and proposed a novel testing method on the fuel cell vehicle powertrain system, which will be a contribution to fuel cell vehicle technology and its industrialization.

  18. Computerized test versus personal interview as admission methods for graduate nursing studies: A retrospective cohort study.

    Science.gov (United States)

    Hazut, Koren; Romem, Pnina; Malkin, Smadar; Livshiz-Riven, Ilana

    2016-12-01

    The purpose of this study was to compare the predictive validity, economic efficiency, and faculty staff satisfaction of a computerized test versus a personal interview as admission methods for graduate nursing studies. A mixed method study was designed, including cross-sectional and retrospective cohorts, interviews, and cost analysis. One hundred and thirty-four students in the Master of Nursing program participated. The success of students in required core courses was similar in both admission method groups. The personal interview method was found to be a significant predictor of success, with cognitive variables the only significant contributors to the model. Higher satisfaction levels were reported with the computerized test compared with the personal interview method. The cost of the personal interview method, in annual hourly work, was 2.28 times higher than the computerized test. These findings may promote discussion regarding the cost benefit of the personal interview as an admission method for advanced academic studies in healthcare professions. © 2016 John Wiley & Sons Australia, Ltd.

  19. Feasibility of supervised self-testing using an oral fluid-based HIV rapid testing method: a cross-sectional, mixed method study among pregnant women in rural India.

    Science.gov (United States)

    Sarkar, Archana; Mburu, Gitau; Shivkumar, Poonam Varma; Sharma, Pankhuri; Campbell, Fiona; Behera, Jagannath; Dargan, Ritu; Mishra, Surendra Kumar; Mehra, Sunil

    2016-01-01

    HIV self-testing can increase coverage of essential HIV services. This study aimed to establish the acceptability, concordance and feasibility of supervised HIV self-testing among pregnant women in rural India. A cross-sectional, mixed methods study was conducted among 202 consenting pregnant women in a rural Indian hospital between August 2014 and January 2015. Participants were provided with instructions on how to self-test using OraQuick(®) HIV antibody test, and subsequently asked to self-test under supervision of a community health worker. Test results were confirmed at a government-run integrated counselling and testing centre. A questionnaire was used to obtain information on patient demographics and the ease, acceptability and difficulties of self-testing. In-depth interviews were conducted with a sub-sample of 35 participants to understand their experiences. In total, 202 participants performed the non-invasive, oral fluid-based, rapid test under supervision for HIV screening. Acceptance rate was 100%. Motivators for self-testing included: ease of testing (43.4%), quick results (27.3%) and non-invasive procedure (23.2%). Sensitivity and specificity were 100% for 201 tests, and one test was invalid. Concordance of test result interpretation between community health workers and participants was 98.5% with a Cohen's Kappa (k) value of k=0.566 with pwomen in rural India. Participants were supportive of making self-testing publicly available. Policy guidelines and implementation research are required to advance HIV self-testing for larger populations at scale.

  20. State of the art in non-animal approaches for skin sensitization testing: from individual test methods towards testing strategies.

    Science.gov (United States)

    Ezendam, Janine; Braakhuis, Hedwig M; Vandebriel, Rob J

    2016-12-01

    The hazard assessment of skin sensitizers relies mainly on animal testing, but much progress is made in the development, validation and regulatory acceptance and implementation of non-animal predictive approaches. In this review, we provide an update on the available computational tools and animal-free test methods for the prediction of skin sensitization hazard. These individual test methods address mostly one mechanistic step of the process of skin sensitization induction. The adverse outcome pathway (AOP) for skin sensitization describes the key events (KEs) that lead to skin sensitization. In our review, we have clustered the available test methods according to the KE they inform: the molecular initiating event (MIE/KE1)-protein binding, KE2-keratinocyte activation, KE3-dendritic cell activation and KE4-T cell activation and proliferation. In recent years, most progress has been made in the development and validation of in vitro assays that address KE2 and KE3. No standardized in vitro assays for T cell activation are available; thus, KE4 cannot be measured in vitro. Three non-animal test methods, addressing either the MIE, KE2 or KE3, are accepted as OECD test guidelines, and this has accelerated the development of integrated or defined approaches for testing and assessment (e.g. testing strategies). The majority of these approaches are mechanism-based, since they combine results from multiple test methods and/or computational tools that address different KEs of the AOP to estimate skin sensitization potential and sometimes potency. Other approaches are based on statistical tools. Until now, eleven different testing strategies have been published, the majority using the same individual information sources. Our review shows that some of the defined approaches to testing and assessment are able to accurately predict skin sensitization hazard, sometimes even more accurate than the currently used animal test. A few defined approaches are developed to provide an

  1. ASTM test methods for composite characterization and evaluation

    Science.gov (United States)

    Masters, John E.

    1994-01-01

    A discussion of the American Society for Testing and Materials is given. Under the topic of composite materials characterization and evaluation, general industry practice and test methods for textile composites are presented.

  2. 49 CFR Appendix B to Part 178 - Alternative Leakproofness Test Methods

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Alternative Leakproofness Test Methods B Appendix... FOR PACKAGINGS Pt. 178, App. B Appendix B to Part 178—Alternative Leakproofness Test Methods In addition to the method prescribed in § 178.604 of this subchapter, the following leakproofness test methods...

  3. New methods of testing nonlinear hypothesis using iterative NLLS estimator

    Science.gov (United States)

    Mahaboob, B.; Venkateswarlu, B.; Mokeshrayalu, G.; Balasiddamuni, P.

    2017-11-01

    This research paper discusses the method of testing nonlinear hypothesis using iterative Nonlinear Least Squares (NLLS) estimator. Takeshi Amemiya [1] explained this method. However in the present research paper, a modified Wald test statistic due to Engle, Robert [6] is proposed to test the nonlinear hypothesis using iterative NLLS estimator. An alternative method for testing nonlinear hypothesis using iterative NLLS estimator based on nonlinear hypothesis using iterative NLLS estimator based on nonlinear studentized residuals has been proposed. In this research article an innovative method of testing nonlinear hypothesis using iterative restricted NLLS estimator is derived. Pesaran and Deaton [10] explained the methods of testing nonlinear hypothesis. This paper uses asymptotic properties of nonlinear least squares estimator proposed by Jenrich [8]. The main purpose of this paper is to provide very innovative methods of testing nonlinear hypothesis using iterative NLLS estimator, iterative NLLS estimator based on nonlinear studentized residuals and iterative restricted NLLS estimator. Eakambaram et al. [12] discussed least absolute deviation estimations versus nonlinear regression model with heteroscedastic errors and also they studied the problem of heteroscedasticity with reference to nonlinear regression models with suitable illustration. William Grene [13] examined the interaction effect in nonlinear models disused by Ai and Norton [14] and suggested ways to examine the effects that do not involve statistical testing. Peter [15] provided guidelines for identifying composite hypothesis and addressing the probability of false rejection for multiple hypotheses.

  4. Formal Functional Test Designs: Bridging the Gap Between Test Requirements and Test Specifications

    Science.gov (United States)

    Hops, Jonathan

    1993-01-01

    This presentation describes the testing life cycle, the purpose of the test design phase, and test design methods and gives an example application. Also included is a description of Test Representation Language (TRL), a summary of the language, and an example of an application of TRL. A sample test requirement and sample test design are included.

  5. Standard Test Method for Bond Strength of Ceramic Tile to Portland Cement Paste

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of the ability of glazed ceramic wall tile, ceramic mosaic tile, quarry tile, and pavers to be bonded to portland cement paste. This test method includes both face-mounted and back-mounted tile. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  6. 77 FR 8865 - Recent Postings of Broadly Applicable Alternative Test Methods

    Science.gov (United States)

    2012-02-15

    ... Applicable Alternative Test Methods AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of availability. SUMMARY: This notice announces the broadly applicable alternative test method approval decisions... INFORMATION CONTACT: An electronic copy of each alternative test method approval document is available on the...

  7. Overview of multi-input frequency domain modal testing methods with an emphasis on sine testing

    Science.gov (United States)

    Rost, Robert W.; Brown, David L.

    1988-01-01

    An overview of the current state of the art multiple-input, multiple-output modal testing technology is discussed. A very brief review of the current time domain methods is given. A detailed review of frequency and spatial domain methods is presented with an emphasis on sine testing.

  8. Validation of qualitative microbiological test methods

    NARCIS (Netherlands)

    IJzerman-Boon, Pieta C.; van den Heuvel, Edwin R.

    2015-01-01

    This paper considers a statistical model for the detection mechanism of qualitative microbiological test methods with a parameter for the detection proportion (the probability to detect a single organism) and a parameter for the false positive rate. It is demonstrated that the detection proportion

  9. A review of a radioactive material shipping container including design, testing, upgrading compliance program and shipping logistics

    International Nuclear Information System (INIS)

    Celovsky, A.; Lesco, R.; Gale, B.; Sypes, J.

    2003-01-01

    Ten years ago Atomic Energy of Canada developed a Type B(U)-85 shipping container for the global transport of highly radioactive materials. This paper reviews the development of the container, including a summary of the design requirements, a review of the selected materials and key design elements, and the results of the major qualification tests (drop testing, fire test, leak tightness testing, and shielding integrity tests). As a result of the testing, improvements to the structural, thermal and containment design were made. Such improvements, and reasons thereof, are noted. Also provided is a summary of the additional analysis work required to upgrade the package from a Type B(U) to a Type B(F), i.e. essentially upgrading the container to include fissile radioisotopes to the authorized radioactive contents list. Having a certified shipping container is only one aspect governing the global shipments of radioactive material. By necessity the shipment of radioactive material is a highly regulated environment. This paper also explores the experiences with other key aspects of radioactive shipments, including the service procedures used to maintain the container certification, the associated compliance program for radioactive material shipments, and the shipping logistics involved in the transport. (author)

  10. 46 CFR 57.06-3 - Method of performing production testing.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Method of performing production testing. 57.06-3 Section 57.06-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING WELDING AND BRAZING Production Tests § 57.06-3 Method of performing production testing. (a) Except as...

  11. A new modification of summary-based analysis method for large software system testing

    Directory of Open Access Journals (Sweden)

    A. V. Sidorin

    2015-01-01

    Full Text Available The automated testing tools becoming a frequent practice require thorough computer-aided testing of large software systems, including system inter-component interfaces. To achieve a good coverage, one should overcome scalability problems of different methods of analysis. These problems arise from impossibility to analyze all the execution paths. The objective of this research is to build a method for inter-procedural analysis, which efficiency enables us to analyse large software systems (such as Android OS codebase as a whole for a reasonable time (no more than 4 hours. This article reviews existing methods of software analysis to detect their potential defects. It focuses on the symbolic execution method since it is widely used both in static analysis of source code and in hybrid analysis of object files and intermediate representation (concolic testing. The method of symbolic execution involves separation of a set of input data values into equivalence classes while choosing an execution path. The paper also considers advantages of this method and its shortcomings. One of the main scalability problems is related to inter-procedural analysis. Analysis time grows rapidly if an inlining method is used for inter-procedural analysis. So this work proposes a summary-based analysis method to solve scalability problems. Clang Static Analyzer, an open source static analyzer (a part of the LLVM project, has been chosen as a target system. It allows us to compare performance of inlining and summary-based inter-procedural analysis. A mathematical model for preliminary estimations is described in order to identify possible factors of performance improvement.

  12. Finite test sets development method for test execution of safety critical software

    International Nuclear Information System (INIS)

    El-Bordany Ayman; Yun, Won Young

    2014-01-01

    It reads inputs, computes new states, and updates output for each scan cycle. Korea Nuclear Instrumentation and Control System (KNICS) has recently developed a fully digitalized Reactor Protection System (RPS) based on PLD. As a digital system, this RPS is equipped with a dedicated software. The Reliability of this software is crucial to NPPs safety where its malfunction may cause irreversible consequences and affect the whole system as a Common Cause Failure (CCF). To guarantee the reliability of the whole system, the reliability of this software needs to be quantified. There are three representative methods for software reliability quantification, namely the Verification and Validation (V and V) quality-based method, the Software Reliability Growth Model (SRGM), and the test-based method. An important concept of the guidance is that the test sets represent 'trajectories' (a series of successive values for the input variables of a program that occur during the operation of the software over time) in the space of inputs to the software.. Actually, the inputs to the software depends on the state of plant at that time, and these inputs form a new internal state of the software by changing values of some variables. In other words, internal state of the software at specific timing depends on the history of past inputs. Here the internal state of the software which can be changed by past inputs is named as Context of Software (CoS). In a certain CoS, a software failure occurs when a fault is triggered by some inputs. To cover the failure occurrence mechanism of a software, preceding researches insist that the inputs should be a trajectory form. However, in this approach, there are two critical problems. One is the length of the trajectory input. Input trajectory should long enough to cover failure mechanism, but the enough length is not clear. What is worse, to cover some accident scenario, one set of input should represent dozen hours of successive values

  13. Moisture distribution in sludges based on different testing methods

    Institute of Scientific and Technical Information of China (English)

    Wenyi Deng; Xiaodong Li; Jianhua Yan; Fei Wang; Yong Chi; Kefa Cen

    2011-01-01

    Moisture distributions in municipal sewage sludge, printing and dyeing sludge and paper mill sludge were experimentally studied based on four different methods, i.e., drying test, thermogravimetric-differential thermal analysis (TG-DTA) test, thermogravimetricdifferential scanning calorimetry (TG-DSC) test and water activity test. The results indicated that the moistures in the mechanically dewatered sludges were interstitial water, surface water and bound water. The interstitial water accounted for more than 50% wet basis (wb) of the total moisture content. The bond strength of sludge moisture increased with decreasing moisture content, especially when the moisture content was lower than 50% wb. Furthermore, the comparison among the four different testing methods was presented.The drying test was advantaged by its ability to quantify free water, interstitial water, surface water and bound water; while TG-DSC test, TG-DTA test and water activity test were capable of determining the bond strength of moisture in sludge. It was found that the results from TG-DSC and TG-DTA test are more persuasive than water activity test.

  14. [Testing methods for seed quality of Bletilla striata].

    Science.gov (United States)

    Zhang, Zhi-Hui; Liu, Da-Hui; Zhu, Xin-Yan; Ji, Peng-Zhang; Wang, Li; Shi, Ya-Na; Ma, Cong-Ji

    2016-06-01

    In order to provide a basis for establishing seed testing rules and seed quality standard of Bletilla striata, the seed quality of B.striata from different producing area was measured referring to the Rules for Agricultural Seed Testing(GB/T 3543-1995).The results showed that the seeds of B.striata passed through 20-mesh sieve for purity analysis.The weight of seeds was measured by 1000-seed method and the water content was measured at the higher temperature (133±2) ℃ for 3 hours.The seeds were cultured on the wet filter paper at 30 ℃ for 4-20 days in light for germination testing.The method of testing seed viability was that seeds were dipped into 1% TTC solution for 7 hours at temperature of 40 ℃. Copyright© by the Chinese Pharmaceutical Association.

  15. Comparison of System Identification Methods using Ambient Bridge Test Data

    DEFF Research Database (Denmark)

    Andersen, P.; Brincker, Rune; Peeters, B.

    1999-01-01

    In this paper the performance of four different system identification methods is compared using operational data obtained from an ambient vibration test of the Swiss Z24 highway bridge. The four methods are the frequency domain based peak-picking methods, the polyreference LSCE method, the stocha......In this paper the performance of four different system identification methods is compared using operational data obtained from an ambient vibration test of the Swiss Z24 highway bridge. The four methods are the frequency domain based peak-picking methods, the polyreference LSCE method...

  16. Supplementary test method for carbon filters

    International Nuclear Information System (INIS)

    Normann, B.; Pettersson, S.-O.

    1980-11-01

    A test method for carbon filters using freon to detect leakage is described. The filters are used in nuclear power plants and in air-raid shelters to separate radioactive iodine.Sampling and detection limits are described and a proposal for a complete equipment is made.(G.B.)

  17. Local tolerance testing under REACH: Accepted non-animal methods are not on equal footing with animal tests.

    Science.gov (United States)

    Sauer, Ursula G; Hill, Erin H; Curren, Rodger D; Raabe, Hans A; Kolle, Susanne N; Teubner, Wera; Mehling, Annette; Landsiedel, Robert

    2016-07-01

    In general, no single non-animal method can cover the complexity of any given animal test. Therefore, fixed sets of in vitro (and in chemico) methods have been combined into testing strategies for skin and eye irritation and skin sensitisation testing, with pre-defined prediction models for substance classification. Many of these methods have been adopted as OECD test guidelines. Various testing strategies have been successfully validated in extensive in-house and inter-laboratory studies, but they have not yet received formal acceptance for substance classification. Therefore, under the European REACH Regulation, data from testing strategies can, in general, only be used in so-called weight-of-evidence approaches. While animal testing data generated under the specific REACH information requirements are per se sufficient, the sufficiency of weight-of-evidence approaches can be questioned under the REACH system, and further animal testing can be required. This constitutes an imbalance between the regulatory acceptance of data from approved non-animal methods and animal tests that is not justified on scientific grounds. To ensure that testing strategies for local tolerance testing truly serve to replace animal testing for the REACH registration 2018 deadline (when the majority of existing chemicals have to be registered), clarity on their regulatory acceptance as complete replacements is urgently required. 2016 FRAME.

  18. Systems and Methods for Fabricating Structures Including Metallic Glass-Based Materials Using Low Pressure Casting

    Science.gov (United States)

    Hofmann, Douglas C. (Inventor); Kennett, Andrew (Inventor)

    2018-01-01

    Systems and methods to fabricate objects including metallic glass-based materials using low-pressure casting techniques are described. In one embodiment, a method of fabricating an object that includes a metallic glass-based material includes: introducing molten alloy into a mold cavity defined by a mold using a low enough pressure such that the molten alloy does not conform to features of the mold cavity that are smaller than 100 microns; and cooling the molten alloy such that it solidifies, the solid including a metallic glass-based material.

  19. Method of measurement on materials shielding effectiveness test in time domain

    International Nuclear Information System (INIS)

    Liu Shunkun; Han Jun; Chen Xiangyue

    2009-01-01

    Windows method is a measurement of slot coupling effect in nature when it is used to measure material's shielding effectiveness. The error of measurement will become serious when it is used to measure material's shielding effectiveness in low frequency band. It is difficult to measure material's shielding effectiveness of electromagnetic pulse with Windows method. Device under test method (DUT method) was presented in this paper to overcome the limitations of Windows method in material's shielding effectiveness test. The method can be used to measure any material's shielding Effectiveness effectively through the design and the test of the DUT.The method was used to measure shielding effectiveness of special cement .Compared with theoretical analysis,the measurement result prove the DUT method to be very efficient in material's shielding effectiveness test. (authors)

  20. Characterization methods for ultrasonic test systems

    International Nuclear Information System (INIS)

    Busse, L.J.; Becker, F.L.; Bowey, R.E.; Doctor, S.R.; Gribble, R.P.; Posakony, G.J.

    1982-07-01

    Methods for the characterization of ultrasonic transducers (search units) and instruments are presented. The instrument system is considered as three separate components consisting of a transducer, a receiver-display, and a pulser. The operation of each component is assessed independently. The methods presented were chosen because they provide the greatest amount of information about component operation and were not chosen based upon such conditions as cost, ease of operation, field implementation, etc. The results of evaluating a number of commercially available ultrasonic test instruments are presented

  1. Standard test method for evaluating stress-corrosion cracking of stainless alloys with different nickel content in boiling acidified sodium chloride solution

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This test method describes a procedure for conducting stress-corrosion cracking tests in an acidified boiling sodium chloride solution. This test method is performed in 25% (by mass ) sodium chloride acidified to pH 1.5 with phosphoric acid. This test method is concerned primarily with the test solution and glassware, although a specific style of U-bend test specimen is suggested. 1.2 This test method is designed to provide better correlation with chemical process industry experience for stainless steels than the more severe boiling magnesium chloride test of Practice G36. Some stainless steels which have provided satisfactory service in many environments readily crack in Practice G36, but have not cracked during interlaboratory testing using this sodium chloride test method. 1.3 This boiling sodium chloride test method was used in an interlaboratory test program to evaluate wrought stainless steels, including duplex (ferrite-austenite) stainless and an alloy with up to about 33% nickel. It may also b...

  2. A test case of the deformation rate analysis (DRA) stress measurement method

    Energy Technology Data Exchange (ETDEWEB)

    Dight, P.; Hsieh, A. [Australian Centre for Geomechanics, Univ. of WA, Crawley (Australia); Johansson, E. [Saanio and Riekkola Oy, Helsinki (Finland); Hudson, J.A. [Rock Engineering Consultants (United Kingdom); Kemppainen, K.

    2012-01-15

    As part of Posiva's site and ONKALO investigations, the in situ rock stress has been measured by a variety of techniques, including hydraulic fracturing, overcoring, and convergence measurements. All these techniques involve direct measurements in a drillhole or at the rock surface. An alternative method is to test drillhole core in a way that enables estimation of the magnitudes and orientations of the in situ rock stress. The Kaiser Effect (KE) and Deformation Rate Analysis (DRA) are two ways to do this. In the work reported here, a 'blind' DRA test was conducted on core obtained from the POSE (Posiva's Olkiluoto Spalling Experiment) niche in the ONKALO. The term 'blind' means that the two first authors of this report, who conducted the tests at the Australian Centre for Geomechanics, did not know the depths below surface at which the cores had been obtained. The results of this DRA Test Case are presented, together with an explanation of the DRA procedure. Also, additional information that would help in such DRA testing and associated analysis is explained. One of the problems in comparing the DRA results with the known Olkiluoto stress field is that the latter is highly variable across the site, as experienced by the previous in situ stress measurements and as predicted by numerical analysis. The variability is mainly caused by the presence of the large brittle deformation zones which perturb the local stress state. However, this variability reduces with depth and the stress field becomes more stable at the {approx} 350 m at which the drillhole cores were obtained. Another compounding difficulty is that the stress quantity, being a second order tensor, requires six independent components for its specification. In other words, comparison of the DRA results and the known stress field requires comparison of six different quantities. In terms of the major principal stress orientation, the DRA results predict an orientation completely

  3. A test case of the deformation rate analysis (DRA) stress measurement method

    International Nuclear Information System (INIS)

    Dight, P.; Hsieh, A.; Johansson, E.; Hudson, J.A.; Kemppainen, K.

    2012-01-01

    As part of Posiva's site and ONKALO investigations, the in situ rock stress has been measured by a variety of techniques, including hydraulic fracturing, overcoring, and convergence measurements. All these techniques involve direct measurements in a drillhole or at the rock surface. An alternative method is to test drillhole core in a way that enables estimation of the magnitudes and orientations of the in situ rock stress. The Kaiser Effect (KE) and Deformation Rate Analysis (DRA) are two ways to do this. In the work reported here, a 'blind' DRA test was conducted on core obtained from the POSE (Posiva's Olkiluoto Spalling Experiment) niche in the ONKALO. The term 'blind' means that the two first authors of this report, who conducted the tests at the Australian Centre for Geomechanics, did not know the depths below surface at which the cores had been obtained. The results of this DRA Test Case are presented, together with an explanation of the DRA procedure. Also, additional information that would help in such DRA testing and associated analysis is explained. One of the problems in comparing the DRA results with the known Olkiluoto stress field is that the latter is highly variable across the site, as experienced by the previous in situ stress measurements and as predicted by numerical analysis. The variability is mainly caused by the presence of the large brittle deformation zones which perturb the local stress state. However, this variability reduces with depth and the stress field becomes more stable at the ∼ 350 m at which the drillhole cores were obtained. Another compounding difficulty is that the stress quantity, being a second order tensor, requires six independent components for its specification. In other words, comparison of the DRA results and the known stress field requires comparison of six different quantities. In terms of the major principal stress orientation, the DRA results predict an orientation completely different to the NW-SE regional

  4. Solar cells, structures including organometallic halide perovskite monocrystalline films, and methods of preparation thereof

    KAUST Repository

    Bakr, Osman; Peng, Wei; Wang, Lingfei

    2017-01-01

    Embodiments of the present disclosure provide for solar cells including an organometallic halide perovskite monocrystalline film (see fig. 1.1B), other devices including the organometallic halide perovskite monocrystalline film, methods of making

  5. In Situ Estuarine and Marine Toxicity Testing: A Review, Including Recommendations for Future Use in Ecological Risk Assessment

    Science.gov (United States)

    2009-09-01

    field and microcosms than they do under laboratory test conditions. In the case of tributyltin ( TBT ) exposures in San Diego Bay, he found that...TECHNICAL REPORT 1986 September 2009 In Situ Estuarine and Marine Toxicity Testing A Review, Including Recommendations for Future Use in...Pacific TECHNICAL REPORT 1986 September 2009 In Situ Estuarine and Marine Toxicity Testing A Review, Including Recommendations for Future Use in

  6. Test strip and method for its use

    International Nuclear Information System (INIS)

    1981-01-01

    A test strip device is described which is useful in performing binding assays involving antigens, antibodies, hormones, vitamins, metabolites or pharmacological agents. The device is capable of application to analytical methods in which a set of sequential test reactions is involved and in which a minute sample size may be used. This test strip is particularly useful in radioimmunoassays. The use of the device is illustrated in radioimmunoassays for 1) thyroxine in serum, 2) the triiodothyronine binding capacity of serum and 3) folic acid and its analogues in serum. (U.K.)

  7. Standard Test Methods for Photovoltaic Modules in Cyclic Temperature and Humidity Environments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods provide procedures for stressing photovoltaic modules in simulated temperature and humidity environments. Environmental testing is used to simulate aging of module materials on an accelerated basis. 1.2 Three individual environmental test procedures are defined by these test methods: a thermal cycling procedure, a humidity-freeze cycling procedure, and an extended duration damp heat procedure. Electrical biasing is utilized during the thermal cycling procedure to simulate stresses that are known to occur in field-deployed modules. 1.3 These test methods define mounting methods for modules undergoing environmental testing, and specify parameters that must be recorded and reported. 1.4 These test methods do not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of these test methods. 1.5 Any of the individual environmental tests may be performed singly, or may be combined into a test sequence with other environmental or non-envir...

  8. Standard test method for determining nodularity and nodule count in ductile iron using image analysis

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method is used to determine the percent nodularity and the nodule count per unit area (that is, number of nodules per mm2) using a light microscopical image of graphite in nodular cast iron. Images generated by other devices, such as a scanning electron microscope, are not specifically addressed, but can be utilized if the system is calibrated in both x and y directions. 1.2 Measurement of secondary or temper carbon in other types of cast iron, for example, malleable cast iron or in graphitic tool steels, is not specifically included in this standard because of the different graphite shapes and sizes inherent to such grades 1.3 This standard deals only with the recommended test method and nothing in it should be construed as defining or establishing limits of acceptability or fitness for purpose of the material tested. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address al...

  9. Influence of Specimen Preparation and Test Methods on the Flexural Strength Results of Monolithic Zirconia Materials.

    Science.gov (United States)

    Schatz, Christine; Strickstrock, Monika; Roos, Malgorzata; Edelhoff, Daniel; Eichberger, Marlis; Zylla, Isabella-Maria; Stawarczyk, Bogna

    2016-03-09

    The aim of this work was to evaluate the influence of specimen preparation and test method on the flexural strength results of monolithic zirconia. Different monolithic zirconia materials (Ceramill Zolid (Amann Girrbach, Koblach, Austria), Zenostar ZrTranslucent (Wieland Dental, Pforzheim, Germany), and DD Bio zx² (Dental Direkt, Spenge, Germany)) were tested with three different methods: 3-point, 4-point, and biaxial flexural strength. Additionally, different specimen preparation methods were applied: either dry polishing before sintering or wet polishing after sintering. Each subgroup included 40 specimens. The surface roughness was assessed using scanning electron microscopy (SEM) and a profilometer whereas monoclinic phase transformation was investigated with X-ray diffraction. The data were analyzed using a three-way Analysis of Variance (ANOVA) with respect to the three factors: zirconia, specimen preparation, and test method. One-way ANOVA was conducted for the test method and zirconia factors within the combination of two other factors. A 2-parameter Weibull distribution assumption was applied to analyze the reliability under different testing conditions. In general, values measured using the 4-point test method presented the lowest flexural strength values. The flexural strength findings can be grouped in the following order: 4-point strength values than prepared before sintering. The Weibull moduli ranged from 5.1 to 16.5. Specimens polished before sintering showed higher surface roughness values than specimens polished after sintering. In contrast, no strong impact of the polishing procedures on the monoclinic surface layer was observed. No impact of zirconia material on flexural strength was found. The test method and the preparation method significantly influenced the flexural strength values.

  10. Test methods for determining asphaltene stability in crude oils

    Energy Technology Data Exchange (ETDEWEB)

    Asomaning, S. [Baker Petrolite, Sugar Land, TX (United States)

    2001-07-01

    The development of test methods for the determination of the stability of asphaltenes in crude oils was rendered necessary, due to the high cost of remediating asphaltene deposition in harsh production environments, namely the underwater systems in offshore deepwater. The Oliensis Spot Test, two saturates, aromatics, resins and asphaltenes (SARA)-based screens (the Colloidal Instability Index and Asphaltene-Resin ratio), a solvent titration method with near infrared radiation (NIR) solids detection, and live oil depressurization were used for the purposes of this study, to predict the stability of asphaltenes in crude oils with different API gravity. A complete description of the test methods was provided, and the experimental data obtained as a result was presented. Correlation with data on the deposition histories of the oils was used to validate the experimental stability data. The author discussed the effectiveness of the different tests for the prediction of the stability of asphaltenes in crude oils. The prediction of a crude oil's propensity towards asphaltene precipitation was more accurate with the Colloidal Instability Index and the solvent titration method. Live oil depressurization proved to be very effective for the prediction of the stability of asphaltenes for light oils, where most stability tests fail. tabs., 31 figs.

  11. Electrode assemblies, plasma apparatuses and systems including electrode assemblies, and methods for generating plasma

    Science.gov (United States)

    Kong, Peter C; Grandy, Jon D; Detering, Brent A; Zuck, Larry D

    2013-09-17

    Electrode assemblies for plasma reactors include a structure or device for constraining an arc endpoint to a selected area or region on an electrode. In some embodiments, the structure or device may comprise one or more insulating members covering a portion of an electrode. In additional embodiments, the structure or device may provide a magnetic field configured to control a location of an arc endpoint on the electrode. Plasma generating modules, apparatus, and systems include such electrode assemblies. Methods for generating a plasma include covering at least a portion of a surface of an electrode with an electrically insulating member to constrain a location of an arc endpoint on the electrode. Additional methods for generating a plasma include generating a magnetic field to constrain a location of an arc endpoint on an electrode.

  12. A Novel Complementary Method for the Point-Scan Nondestructive Tests Based on Lamb Waves

    Directory of Open Access Journals (Sweden)

    Rahim Gorgin

    2014-01-01

    Full Text Available This study presents a novel area-scan damage identification method based on Lamb waves which can be used as a complementary method for point-scan nondestructive techniques. The proposed technique is able to identify the most probable locations of damages prior to point-scan test which lead to decreasing the time and cost of inspection. The test-piece surface was partitioned with some smaller areas and the damage probability presence of each area was evaluated. A0 mode of Lamb wave was generated and collected using a mobile handmade transducer set at each area. Subsequently, a damage presence probability index (DPPI based on the energy of captured responses was defined for each area. The area with the highest DPPI value highlights the most probable locations of damages in test-piece. Point-scan nondestructive methods can then be used once these areas are found to identify the damage in detail. The approach was validated by predicting the most probable locations of representative damages including through-thickness hole and crack in aluminum plates. The obtained experimental results demonstrated the high potential of developed method in defining the most probable locations of damages in structures.

  13. Leak test method for radioactive material packagings without pressure valve connections

    International Nuclear Information System (INIS)

    Johnson, S.F.; Stenbaeck, A.

    1976-01-01

    A leak test method has been developed at Studsvik which provides the possibility of testing Type B packagings unequipped with valves for evacuation or pressurizing. Even large packagings with pressure valve connections can be leak tested by this method. The method is a pressure test method. The test gas comprises a mixture of helium and nitrogen or helium and air. Excess pressure in a valveless packaging is achieved by vaporization of liquid nitrogen. All parts of the packaging or package where leaks might be expected are covered by plastic sheet. Samples of the gas accumulated under the plastic sheets are taken using evacuated glass ampoules which are initially sealed off to a breakable point. The gas samples are measured with a He-mass spectrometer. The sensitivity of this method of leak testing is, in practice, of the order of 10 -7 atmcm 3 s -1 . (author)

  14. Thermal Testing Methods for Solar Dryers

    DEFF Research Database (Denmark)

    Singh, Shobhana

    2017-01-01

    Solar food drying is a complex heat and mass transfer phenomena which depend on a number of drying process-dependent parameters such as operating conditions and characteristics of the food product to be dried. The variation in these parameters significantly affects the overall performance...... of the dryer system. Since commercial growth and acceptance of any solar dryer system momentously depend on its performance guarantee, the development of a standard methodology for their thermal testing has become necessary. The standard testing method not only provides better performance management...... of the dryer system but allows the manufacturers to achieve competitive efficiency and good product quality by comparing the available designs. In this chapter, an extensive review of solar dryer performance evaluation has been carried out. Furthermore, the chapter describes the existing testing procedures...

  15. "Comparison of some Structural Analyses Methods used for the Test Pavement in the Danish Road Testing Machine

    DEFF Research Database (Denmark)

    Baltzer, S.; Zhang, W.; Macdonald, R.

    1998-01-01

    A flexible test pavement, instrumented to measure stresses and strains in the three primary axes with the upper 400 mm of the subgrade, has been constructed and load tested in the Danish Road Testing Machine (RTM). One objective of this research, which is part of the International Pavement Subgrade...... Pressure Cells, Thermistors and Pore Pressure Sensors. Routine monitoring of instrument responses and surface profiles with a Profilometer and FWD/LWD structural testing were undertaken at regular intervals during the construction and load testing programmes.This paper compares various structural analysis...... methods used for the RTM test pavement with data from FWD testing undertaken after the construction and loading programmes. Multilayer linear elastic forward and backcalculation methods, a finite element program and MS Excel spreadsheet based methods are compared....

  16. Comparative study of flexural strength test methods on CAD/CAM Y-TZP dental ceramics

    Science.gov (United States)

    Xu, Yongxiang; Han, Jianmin; Lin, Hong; An, Linan

    2015-01-01

    Clinically, fractures are the main cause of computer-aided design and computer-aided manufacturing (CAD/CAM) 3 mol%-yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) all-ceramic dental restorations failure because of repetitive occlusal loading. The goal of this work is to study the effect of test methods and specimen’s size on the flexural strength of five ceramic products. Both bi-axial flexure test (BI) and uni-axial flexure tests (UNI), including three-point flexure test (3PF) and four-point flexure test (4PF), are used in this study. For all five products, the flexural strength is as follows: BI > 3PF > 4PF. Furthermore, specimens with smaller size (3PF-s) have higher values than the bigger ones (3PF). The difference between BI and UNI resulted from the edge flaws in ceramic specimens. The relationship between different UNI (including 3PF-s, 3PF and 4PF) can be explained according to Weibull statistical fracture theory. BI is recommended to evaluate the flexural strength of CAD/CAM Y-TZP dental ceramics. PMID:26816646

  17. Comparative study of flexural strength test methods on CAD/CAM Y-TZP dental ceramics.

    Science.gov (United States)

    Xu, Yongxiang; Han, Jianmin; Lin, Hong; An, Linan

    2015-12-01

    Clinically, fractures are the main cause of computer-aided design and computer-aided manufacturing (CAD/CAM) 3 mol%-yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) all-ceramic dental restorations failure because of repetitive occlusal loading. The goal of this work is to study the effect of test methods and specimen's size on the flexural strength of five ceramic products. Both bi-axial flexure test (BI) and uni-axial flexure tests (UNI), including three-point flexure test (3PF) and four-point flexure test (4PF), are used in this study. For all five products, the flexural strength is as follows: BI > 3PF > 4PF. Furthermore, specimens with smaller size (3PF-s) have higher values than the bigger ones (3PF). The difference between BI and UNI resulted from the edge flaws in ceramic specimens. The relationship between different UNI (including 3PF-s, 3PF and 4PF) can be explained according to Weibull statistical fracture theory. BI is recommended to evaluate the flexural strength of CAD/CAM Y-TZP dental ceramics.

  18. Wada-test, functional magnetic resonance imaging and direct electrical stimulation - brain mapping methods

    International Nuclear Information System (INIS)

    Minkin, K.; Tanova, R.; Busarski, A.; Penkov, M.; Penev, L.; Hadjidekov, V.

    2009-01-01

    Modern neurosurgery requires accurate preoperative and intraoperative localization of brain pathologies but also of brain functions. The presence of individual variations in healthy subjects and the shift of brain functions in brain diseases provoke the introduction of various methods for brain mapping. The aim of this paper was to analyze the most widespread methods for brain mapping: Wada-test, functional magnetic resonance imaging (fMRI) and intraoperative direct electrical stimulation (DES). This study included 4 patients with preoperative brain mapping using Wada-test and fMRI. Intraoperative mapping with DES during awake craniotomy was performed in one case. The histopathological diagnosis was low-grade glioma in 2 cases, cortical dysplasia (1 patient) and arteriovenous malformation (1 patient). The brain mapping permits total lesion resection in three of four patients. There was no new postoperative deficit despite surgery near or within functional brain areas. Brain plasticity provoking shift of eloquent areas from their usual locations was observed in two cases. The brain mapping methods allow surgery in eloquent brain areas recognized in the past as 'forbidden areas'. Each method has advantages and disadvantages. The precise location of brain functions and pathologies frequently requires combination of different brain mapping methods. (authors)

  19. testing a consensus conference method by discussing

    African Journals Online (AJOL)

    hi-tech

    2000-10-10

    Oct 10, 2000 ... Objectives: To test the recommended consensus conference methods in Tanzania by discussing the management ... “wrong”, based on recommendations advocated in western ..... future scenarios sponsored the conference.

  20. Test Methods for Effects on Organisms:Springtails

    OpenAIRE

    Krogh, P. H.

    1997-01-01

    NORD-UTTE er Nordisk koordineringsgrupp för utvekling av testmetoder inom toxicologi och ekotoxicology. The Nordic Co-ordination Group for the Development of Test Methods for Toxicology and Ecotoxicology

  1. Accelerated Test Method for Corrosion Protective Coatings

    Data.gov (United States)

    National Aeronautics and Space Administration — This project seeks to develop a new accelerated corrosion test method that predicts the long-term corrosion protection performance of spaceport structure coatings as...

  2. Numerical simulations of granular dynamics: I. Hard-sphere discrete element method and tests

    Science.gov (United States)

    Richardson, Derek C.; Walsh, Kevin J.; Murdoch, Naomi; Michel, Patrick

    2011-03-01

    We present a new particle-based (discrete element) numerical method for the simulation of granular dynamics, with application to motions of particles on small solar system body and planetary surfaces. The method employs the parallel N-body tree code pkdgrav to search for collisions and compute particle trajectories. Collisions are treated as instantaneous point-contact events between rigid spheres. Particle confinement is achieved by combining arbitrary combinations of four provided wall primitives, namely infinite plane, finite disk, infinite cylinder, and finite cylinder, and degenerate cases of these. Various wall movements, including translation, oscillation, and rotation, are supported. We provide full derivations of collision prediction and resolution equations for all geometries and motions. Several tests of the method are described, including a model granular “atmosphere” that achieves correct energy equipartition, and a series of tumbler simulations that show the expected transition from tumbling to centrifuging as a function of rotation rate.

  3. VALIDATION OF THE ASSR TEST THROUGH COMPLEMENTARY AUDIOLOGYICAL METHODS

    Directory of Open Access Journals (Sweden)

    C. Mârtu

    2016-04-01

    Full Text Available Introduction: Auditory Steady State Response (ASSR is an objective method for determining the auditive threshold, applicable and necessary especially in children. The test is extremely important for recommending cochlear implant in children. The aim of the study was to compare pure tone audiometry responses and auditory steady-state thresholds. Materials and method: The study was performed on a group including both patients with normal hearing and with hearing loss. The main inclusion criteria accepted only patients with normal otomicroscopic aspect, normal tympanogram, capable to respond to pure tone audiometry, and with ear conduction thresholds between 0 and 80 dB NHL. The patients with suppurative otic processes or ear malformations were excluded. The research protocol was followed, the tests being performed in soundproofed rooms, starting with pure tone audiometry followed, after a pause, by ASSR determinations at frequencies of 0.5, 1.2 and 4 KHz. The audiological instruments were provided by a single manufacturer. ASSR was recorded at least two times for both borderline intensities, namely the one defining the auditory threshold and the first no-response intensity. The recorded responses were stored in a database and further processed in Excel. Discussion: The differences observed between pure tone audiometry and ASSR thresholds are important at 500 Hz and insignificant at the other frequencies. When approaching the PTA-ASSR relation, whatever the main characteristic between the PTA and ASSR thresholds in one ear, the profile of the lines gap maintains the same shape on the opposite ear. Conclusions: ASSR is a confident objective test, maintaining attention to low frequencies, where some differences might occur.

  4. On the assessment of usability testing methods for children

    NARCIS (Netherlands)

    Markopoulos, P.; Bekker, M.M.

    2003-01-01

    The paper motivates the need to acquire methodological knowledge for involving children as test users in usability testing. It introduces a methodological framework for delineating comparative assessments of usability testing methods for children participants. This framework consists in three

  5. Statistical methods in epidemiology. VII. An overview of the chi2 test for 2 x 2 contingency table analysis.

    Science.gov (United States)

    Rigby, A S

    2001-11-10

    The odds ratio is an appropriate method of analysis for data in 2 x 2 contingency tables. However, other methods of analysis exist. One such method is based on the chi2 test of goodness-of-fit. Key players in the development of statistical theory include Pearson, Fisher and Yates. Data are presented in the form of 2 x 2 contingency tables and a method of analysis based on the chi2 test is introduced. There are many variations of the basic test statistic, one of which is the chi2 test with Yates' continuity correction. The usefulness (or not) of Yates' continuity correction is discussed. Problems of interpretation when the method is applied to k x m tables are highlighted. Some properties of the chi2 the test are illustrated by taking examples from the author's teaching experiences. Journal editors should be encouraged to give both observed and expected cell frequencies so that better information comes out of the chi2 test statistic.

  6. Testing and Validation of the Dynamic Interia Measurement Method

    Science.gov (United States)

    Chin, Alexander; Herrera, Claudia; Spivey, Natalie; Fladung, William; Cloutier, David

    2015-01-01

    This presentation describes the DIM method and how it measures the inertia properties of an object by analyzing the frequency response functions measured during a ground vibration test (GVT). The DIM method has been in development at the University of Cincinnati and has shown success on a variety of small scale test articles. The NASA AFRC version was modified for larger applications.

  7. Comparison of E-test with other conventional susceptibility testing methods for ciprofloxacin and gentamicin against gram negative enteric bacilli.

    Science.gov (United States)

    Ogbolu, D O; Terry-Alli, O A; Daini, O A; Olabiyi, F A; Igharo, E A

    2012-06-01

    Increasing antibiotic resistance in Gram negative bacteria has led to the need for a faster and reliable method for determining antimicrobial susceptibility testing. In a resource poor setting like ours, it's also important to look for methods that will be clinically and economically beneficial to the patient. This study was aimed at evaluating the Epsilometer test (E-test) and conventional methods for determining antimicrobial susceptibility of isolates of Gram-negative enteric bacteria to ciprofloxacin and gentamicin. Disc diffusion, E-test, broth dilution and agar dilution methods were performed on 54 bacterial isolates. Using the E-test, 88.9% of bacterial isolates were resistant to ciprofloxacin, 92.6% were resistant using broth microdilution, 96.3% were resistant using agar dilution and 72.2% were resistant using disc diffusion. Minimum inhibitory concentration (MIC50) of isolates for gentamicin showed significant difference for all the techniques (p 0.05). Both E-test and broth dilution methods showed high levels of agreement (p > 0.05), there were low levels of agreement between E-test and agar dilution method (p < 0.05), especially at MIC50. The E-test can therefore be considered a reliable method to determine antimicrobial susceptibility testing and it gives results which are at least as accurate as those obtained by the broth dilution method.

  8. Satellite Vibration Testing: Angle optimisation method to Reduce Overtesting

    Science.gov (United States)

    Knight, Charly; Remedia, Marcello; Aglietti, Guglielmo S.; Richardson, Guy

    2018-06-01

    Spacecraft overtesting is a long running problem, and the main focus of most attempts to reduce it has been to adjust the base vibration input (i.e. notching). Instead this paper examines testing alternatives for secondary structures (equipment) coupled to the main structure (satellite) when they are tested separately. Even if the vibration source is applied along one of the orthogonal axes at the base of the coupled system (satellite plus equipment), the dynamics of the system and potentially the interface configuration mean the vibration at the interface may not occur all along one axis much less the corresponding orthogonal axis of the base excitation. This paper proposes an alternative testing methodology in which the testing of a piece of equipment occurs at an offset angle. This Angle Optimisation method may have multiple tests but each with an altered input direction allowing for the best match between all specified equipment system responses with coupled system tests. An optimisation process that compares the calculated equipment RMS values for a range of inputs with the maximum coupled system RMS values, and is used to find the optimal testing configuration for the given parameters. A case study was performed to find the best testing angles to match the acceleration responses of the centre of mass and sum of interface forces for all three axes, as well as the von Mises stress for an element by a fastening point. The angle optimisation method resulted in RMS values and PSD responses that were much closer to the coupled system when compared with traditional testing. The optimum testing configuration resulted in an overall average error significantly smaller than the traditional method. Crucially, this case study shows that the optimum test campaign could be a single equipment level test opposed to the traditional three orthogonal direction tests.

  9. Influence of lubricant on the pitting capacity of gears. Comparison and discussion of main pitting test methods

    Energy Technology Data Exchange (ETDEWEB)

    Hoehn, Bernd-Robert; Oster, Peter; Tobie, Thomas; Hergesell, Maria [Forschungsstelle fuer Zahnraeder und Getriebebau, Technische Univ. Muenchen, Garching (Germany)

    2009-07-01

    The lubricant in a gearbox should provide a separating lubricating film between the meshing teeth. Furthermore its main task is the evacuation of the developing heat. Hence the lubricant is also an important influence parameter on the pitting life time of gearsets. Due to the constantly rising demands for higher power transmission of gearsets, also higher demands are made against the performance of the lubricants. In order to quantify the capability and to choose the appropriate lubricant for each application, reliable testing methods are necessary. Therefor today different testing methods are available. Two of the main pitting testing methods are the Standard Pittingtest according to FVA 2/IV [2] and its advancement, the Practice Relevant Pittingtest according to FVA 371 [4]. For the Practice Relevant Pittingtest test gears with profile modification and lengthwise crowning are used, which are superfinished. For the introduction of the Practice Relevant Pittingtest into industrial application a round robin test was performed in co-operation with FVA and DGMK. This paper is discussing the today usual testing methods regarding the pitting load capacity of lubricants and their characteristics in comparison. Furthermore the results of the round robin test and further example results, including pictures of typical pittings, are presented. In addition it is demonstrated, how to deal with the results. On the basis of test experience, knowledge from research projects and other examples typical questions concerning the different testing methods are discussed. Thereby essential requirements for reliable and reproducible results are pointed out and possible limits for the application of the test methods are represented. (orig.)

  10. What Happened to Remote Usability Testing? An Empirical Study of Three Methods

    DEFF Research Database (Denmark)

    Stage, Jan; Andreasen, M. S.; Nielsen, H. V.

    2007-01-01

    The idea of conducting usability tests remotely emerged ten years ago. Since then, it has been studied empirically, and some software organizations employ remote methods. Yet there are still few comparisons involving more than one remote method. This paper presents results from a systematic...... empirical comparison of three methods for remote usability testing and a conventional laboratorybased think-aloud method. The three remote methods are a remote synchronous condition, where testing is conducted in real time but the test monitor is separated spatially from the test subjects, and two remote...

  11. Development of an Antimicrobial Susceptibility Testing Method Suitable for Performing During Space Flight

    Science.gov (United States)

    Jorgensen, James H.; Skweres, Joyce A.; Mishra S. K.; McElmeel, M. Letticia; Maher, Louise A.; Mulder, Ross; Lancaster, Michael V.; Pierson, Duane L.

    1997-01-01

    Very little is known regarding the affects of the microgravity environment of space flight upon the action of antimicrobial agents on bacterial pathogens. This study was undertaken to develop a simple method for conducting antibacterial susceptibility tests during a Space Shuttle mission. Specially prepared susceptibility test research cards (bioMerieux Vitek, Hazelwood, MO) were designed to include 6-11 serial two-fold dilutions of 14 antimicrobial agents, including penicillins, cephalosporins, a Beta-lactamase inhibitor, vancomycin, erythromycin, tetracycline, gentamicin, ciprofloxacin, and trimethoprim/sulfamethoxazole. Minimal inhibitory concentrations (MICS) of the drugs were determined by visual reading of color endpoints in the Vitek research cards made possible by incorporation of a colorimetric growth indicator (alamarBlue(Trademark), Accumed International, Westlake, OH). This study has demonstrated reproducible susceptibility results when testing isolates of Staphylococcus aurezis, Group A Streptococcus, Enterococcusfaecalis, Escherichia coli (beta-lactamase positive and negative strains), Klebsiella pneumoniae, Enterobacter cloacae, and Pseudomoiias aeruginosa. In some instances, the MICs were comparable to those determined using a standard broth microdilution method, while in some cases the unique test media and format yielded slightly different values, that were themselves reproducible. The proposed in-flight experiment will include inoculation of the Vitek cards on the ground prior to launch of the Space Shuttle, storage of inoculated cards at refrigeration temperature aboard the Space Shuttle until experiment initiation, then incubation of the cards for 18-48 h prior to visual interpretation of MICs by the mission's astronauts. Ground-based studies have shown reproducible MICs following storage of inoculated cards for 7 days at 4-8 C to accommodate the mission's time schedule and the astronauts' activities. For comparison, ground-based control

  12. Standard Test Method for Measuring Heat Flux Using Flush-Mounted Insert Temperature-Gradient Gages

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method describes the measurement of the net heat flux normal to a surface using gages inserted flush with the surface. The geometry is the same as heat-flux gages covered by Test Method E 511, but the measurement principle is different. The gages covered by this standard all use a measurement of the temperature gradient normal to the surface to determine the heat that is exchanged to or from the surface. Although in a majority of cases the net heat flux is to the surface, the gages operate by the same principles for heat transfer in either direction. 1.2 This general test method is quite broad in its field of application, size and construction. Two different gage types that are commercially available are described in detail in later sections as examples. A summary of common heat-flux gages is given by Diller (1). Applications include both radiation and convection heat transfer. The gages used for aerospace applications are generally small (0.155 to 1.27 cm diameter), have a fast time response ...

  13. INTER LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON

    Science.gov (United States)

    2018-03-26

    data by Instrumentation for Impact  Test , SAE standard J211‐1 [4]. Although the entire curve is collected, the interest of this  project  team  solely...HELMET BLUNT IMPACT TEST METHOD COMPARISON by Tony J. Kayhart Charles A. Hewitt and Jonathan Cyganik March 2018 Final...INTER-LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR

  14. Application of WST-method fore fracture testing of fibre-reinforced concrete

    DEFF Research Database (Denmark)

    Löfgren, Ingemar; Olesen, John Forbes; Flansbjer, Mathias

    be drawn from this study are that: § the wedge-splitting test method is a suitable test method for assessment of fracture properties of steel fibre-reinforced concrete; § the test method is easy to handle and relatively fast to execute § the test can be run with CMOD-control or without, in a machine...... more than three times the fibre length; § using inverse analysis, the tensile fracture properties can be interpreted from the test result as a bi-linear stress-crack opening relationship.......To evaluate the reproducibility of the wedge-splitting test method and to provide guidelines, a round robin study was conducted in which three labs participated. The participating labs were: § DTU – the Technical University of Denmark, Department of Civil Engineering; § CTH – Chalmers University...

  15. Lactose tolerance tests

    Science.gov (United States)

    Hydrogen breath test for lactose tolerance ... Two common methods include: Lactose tolerance blood test Hydrogen breath test The hydrogen breath test is the preferred method. It measures the amount of hydrogen ...

  16. Validation and Verification (V and V) Testing on Midscale Flame Resistant (FR) Test Method

    Science.gov (United States)

    2016-12-16

    materials . The results demonstrated that the Midscale test is a quick and cost-effective method for evaluation of FR performance of design features...standard and novel FR materials and design configurations during fire engulfment. Details of the test method and its development can be found in the...employed in the FRACU is a ripstop fabric blend of 65% FR rayon, 25% para- aramid and 10% nylon. The iCVC material is Nylon/Cotton/Nomex. All three

  17. Standard test method for calibration of surface/stress measuring devices

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    Return to Contents page 1.1 This test method covers calibration or verification of calibration, or both, of surface-stress measuring devices used to measure stress in annealed and heat-strengthened or tempered glass using polariscopic or refractometry based principles. 1.2 This test method is nondestructive. 1.3 This test method uses transmitted light, and therefore, is applicable to light-transmitting glasses. 1.4 This test method is not applicable to chemically tempered glass. 1.5 Using the procedure described, surface stresses can be measured only on the “tin” side of float glass. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  18. Small punch test evaluation methods for material characterisation

    Energy Technology Data Exchange (ETDEWEB)

    Janča, Adam, E-mail: adam.janca@fjfi.cvut.cz; Siegl, Jan, E-mail: jan.siegl@fjfi.cvut.cz; Haušild, Petr, E-mail: petr.hausild@fjfi.cvut.cz

    2016-12-01

    The Small Punch Test (SPT) is one of the most widespread mechanical testing methods using miniaturized specimens. The paper presented deals with the time independent SPT, in which a flat specimen is bent by means of a (hemi)spherical punch moving at a constant velocity. The main goal is to relate the measured data to deformation processes taking place during specimen loading. Understanding of such relations is crucial for characterizing a material using any non-standardized experimental procedure. Using enhanced instrumentation, not only traditional load-displacement or load-deflection curves could be obtained, but also specimen thinning could be continuously measured and evaluated. Five alloys having a broad range of mechanical properties were tested. The results obtained were evaluated using both traditional and newly proposed methods and they were correlated with results of the conventional tensile test. The methods proposed seem to lead to a universal correlation between SPT results and tensile characteristics. - Highlights: • The newly proposed methodology significantly improved results of SPT. • Plastic deformation starts inside the specimen from the very beginning of loading. • Specimen thinning = punch displacement−specimen deflection. • Material response to loading is well illustrated by the novel load-thinning curve.

  19. A frequency domain linearized Navier-Stokes method including acoustic damping by eddy viscosity using RANS

    Science.gov (United States)

    Holmberg, Andreas; Kierkegaard, Axel; Weng, Chenyang

    2015-06-01

    In this paper, a method for including damping of acoustic energy in regions of strong turbulence is derived for a linearized Navier-Stokes method in the frequency domain. The proposed method is validated and analyzed in 2D only, although the formulation is fully presented in 3D. The result is applied in a study of the linear interaction between the acoustic and the hydrodynamic field in a 2D T-junction, subject to grazing flow at Mach 0.1. Part of the acoustic energy at the upstream edge of the junction is shed as harmonically oscillating disturbances, which are conveyed across the shear layer over the junction, where they interact with the acoustic field. As the acoustic waves travel in regions of strong shear, there is a need to include the interaction between the background turbulence and the acoustic field. For this purpose, the oscillation of the background turbulence Reynold's stress, due to the acoustic field, is modeled using an eddy Newtonian model assumption. The time averaged flow is first solved for using RANS along with a k-ε turbulence model. The spatially varying turbulent eddy viscosity is then added to the spatially invariant kinematic viscosity in the acoustic set of equations. The response of the 2D T-junction to an incident acoustic field is analyzed via a plane wave scattering matrix model, and the result is compared to experimental data for a T-junction of rectangular ducts. A strong improvement in the agreement between calculation and experimental data is found when the modification proposed in this paper is implemented. Discrepancies remaining are likely due to inaccuracies in the selected turbulence model, which is known to produce large errors e.g. for flows with significant rotation, which the grazing flow across the T-junction certainly is. A natural next step is therefore to test the proposed methodology together with more sophisticated turbulence models.

  20. Solar cells, structures including organometallic halide perovskite monocrystalline films, and methods of preparation thereof

    KAUST Repository

    Bakr, Osman M.

    2017-03-02

    Embodiments of the present disclosure provide for solar cells including an organometallic halide perovskite monocrystalline film (see fig. 1.1B), other devices including the organometallic halide perovskite monocrystalline film, methods of making organometallic halide perovskite monocrystalline film, and the like.

  1. Simplified pressure method for respirator fit testing.

    Science.gov (United States)

    Han, D; Xu, M; Foo, S; Pilacinski, W; Willeke, K

    1991-08-01

    A simplified pressure method has been developed for fit testing air-purifying respirators. In this method, the air-purifying cartridges are replaced by a pressure-sensing attachment and a valve. While wearers hold their breath, a small pump extracts air from the respirator cavity until a steady-state pressure is reached in 1 to 2 sec. The flow rate through the face seal leak is a unique function of this pressure, which is determined once for all respirators, regardless of the respirator's cavity volume or deformation because of pliability. The contaminant concentration inside the respirator depends on the degree of dilution by the flow through the cartridges. The cartridge flow varies among different brands and is measured once for each brand. The ratio of cartridge to leakflow is a measure of fit. This flow ratio has been measured on human subjects and has been compared to fit factors determined on the same subjects by means of photometric and particle count tests. The aerosol tests gave higher values of fit.

  2. Alternative Testing Methods for Predicting Health Risk from Environmental Exposures

    Directory of Open Access Journals (Sweden)

    Annamaria Colacci

    2014-08-01

    Full Text Available Alternative methods to animal testing are considered as promising tools to support the prediction of toxicological risks from environmental exposure. Among the alternative testing methods, the cell transformation assay (CTA appears to be one of the most appropriate approaches to predict the carcinogenic properties of single chemicals, complex mixtures and environmental pollutants. The BALB/c 3T3 CTA shows a good degree of concordance with the in vivo rodent carcinogenesis tests. Whole-genome transcriptomic profiling is performed to identify genes that are transcriptionally regulated by different kinds of exposures. Its use in cell models representative of target organs may help in understanding the mode of action and predicting the risk for human health. Aiming at associating the environmental exposure to health-adverse outcomes, we used an integrated approach including the 3T3 CTA and transcriptomics on target cells, in order to evaluate the effects of airborne particulate matter (PM on toxicological complex endpoints. Organic extracts obtained from PM2.5 and PM1 samples were evaluated in the 3T3 CTA in order to identify effects possibly associated with different aerodynamic diameters or airborne chemical components. The effects of the PM2.5 extracts on human health were assessed by using whole-genome 44 K oligo-microarray slides. Statistical analysis by GeneSpring GX identified genes whose expression was modulated in response to the cell treatment. Then, modulated genes were associated with pathways, biological processes and diseases through an extensive biological analysis. Data derived from in vitro methods and omics techniques could be valuable for monitoring the exposure to toxicants, understanding the modes of action via exposure-associated gene expression patterns and to highlight the role of genes in key events related to adversity.

  3. A Modified Generalized Fisher Method for Combining Probabilities from Dependent Tests

    Directory of Open Access Journals (Sweden)

    Hongying (Daisy eDai

    2014-02-01

    Full Text Available Rapid developments in molecular technology have yielded a large amount of high throughput genetic data to understand the mechanism for complex traits. The increase of genetic variants requires hundreds and thousands of statistical tests to be performed simultaneously in analysis, which poses a challenge to control the overall Type I error rate. Combining p-values from multiple hypothesis testing has shown promise for aggregating effects in high-dimensional genetic data analysis. Several p-value combining methods have been developed and applied to genetic data; see [Dai, et al. 2012b] for a comprehensive review. However, there is a lack of investigations conducted for dependent genetic data, especially for weighted p-value combining methods. Single nucleotide polymorphisms (SNPs are often correlated due to linkage disequilibrium. Other genetic data, including variants from next generation sequencing, gene expression levels measured by microarray, protein and DNA methylation data, etc. also contain complex correlation structures. Ignoring correlation structures among genetic variants may lead to severe inflation of Type I error rates for omnibus testing of p-values. In this work, we propose modifications to the Lancaster procedure by taking the correlation structure among p-values into account. The weight function in the Lancaster procedure allows meaningful biological information to be incorporated into the statistical analysis, which can increase the power of the statistical testing and/or remove the bias in the process. Extensive empirical assessments demonstrate that the modified Lancaster procedure largely reduces the Type I error rates due to correlation among p-values, and retains considerable power to detect signals among p-values. We applied our method to reassess published renal transplant data, and identified a novel association between B cell pathways and allograft tolerance.

  4. Methods and characteristics of assembly language software testing

    International Nuclear Information System (INIS)

    Wang Lingfang

    2001-01-01

    Single chip micro-controllers are widely implemented to the controlling and testing products in industrial controlling and national defence embedded controlling systems. The invalidation of the source programs could lead to the unreliability of the whole systems, even to cause fatal results. Therefore, software testing is the necessary measures to reduce the mistakes and to improve the quality of the software. In the paper, the development of the software testing is presented. The distinctions between the assembly language testing and those of the high level languages is introduced. And the essential flow and methods of software testing are discussed in detail

  5. Study on operation I and C DCS test method of EPR project

    International Nuclear Information System (INIS)

    Meng Ying; Lv Zhihong; Huang Xinnian; Fan Haiying; Li Zhuojia; Xiao Shushu

    2014-01-01

    Through summarization and optimization of the method for operation I and C DCS test of the European pressurized reactor project, the conclusions play a guiding role on the operation I and C DCS test of the domestic advanced nuclear power plant. The study of the method focuses on the test platform, the test process and the optimization of method of operation I and C DCS test with the practical experience. The reasonable and reliable test method for operation I and C DCS test of the European pressurized reactor project is worthy of the reference and the development in the project of the domestic advanced nuclear power plant. (authors)

  6. 40 CFR 63.1046 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ...) National Emission Standards for Oil-Water Separators and Organic-Water Separators § 63.1046 Test methods... vapor leakage could occur) on the cover and associated closure devices shall be checked. Potential leak... test, the cover and closure devices shall be secured in the closed position. (3) The detection...

  7. Methods and models for the construction of weakly parallel tests

    NARCIS (Netherlands)

    Adema, J.J.; Adema, Jos J.

    1990-01-01

    Methods are proposed for the construction of weakly parallel tests, that is, tests with the same test information function. A mathematical programing model for constructing tests with a prespecified test information function and a heuristic for assigning items to tests such that their information

  8. Standard Test Method for Normal Spectral Emittance at Elevated Temperatures

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1972-01-01

    1.1 This test method describes a highly accurate technique for measuring the normal spectral emittance of electrically conducting materials or materials with electrically conducting substrates, in the temperature range from 600 to 1400 K, and at wavelengths from 1 to 35 μm. 1.2 The test method requires expensive equipment and rather elaborate precautions, but produces data that are accurate to within a few percent. It is suitable for research laboratories where the highest precision and accuracy are desired, but is not recommended for routine production or acceptance testing. However, because of its high accuracy this test method can be used as a referee method to be applied to production and acceptance testing in cases of dispute. 1.3 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this stan...

  9. Standard Test Methods for Determining Mechanical Integrity of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods cover procedures for determining the ability of photovoltaic modules to withstand the mechanical loads, stresses and deflections used to simulate, on an accelerated basis, high wind conditions, heavy snow and ice accumulation, and non-planar installation effects. 1.1.1 A static load test to 2400 Pa is used to simulate wind loads on both module surfaces 1.1.2 A static load test to 5400 Pa is used to simulate heavy snow and ice accumulation on the module front surface. 1.1.3 A twist test is used to simulate the non-planar mounting of a photovoltaic module by subjecting it to a twist angle of 1.2°. 1.1.4 A cyclic load test of 10 000 cycles duration and peak loading to 1440 Pa is used to simulate dynamic wind or other flexural loading. Such loading might occur during shipment or after installation at a particular location. 1.2 These test methods define photovoltaic test specimens and mounting methods, and specify parameters that must be recorded and reported. 1.3 Any individual mech...

  10. An Alternative Corrosion Resistance Test Method for Solar Cells and Interconnection Materials Limiting the Number of Long-lasting and Expensive Damp-Heat Climate Chamber Tests

    Energy Technology Data Exchange (ETDEWEB)

    Van Aken, B.B.; Gouwen, R.J.; Veldman, D.; Bende, E.E.; Eerenstein, W. [ECN Solar Energy, Petten (Netherlands)

    2013-06-15

    Damp-heat testing of PV modules is a time-consuming process, taking months. We present an alternative test method: electrochemical noise (EcN) measurements. Data acquisition times vary between minutes for direct exposure to several tens of hours for encapsulated samples. EcN measurements are presented for several solar cell concepts and different environments. We have found that the degradation in damp-heat testing is proportional to the electrochemical noise signal. In conclusion, the electrochemical noise measurements are a fast, versatile tool to test the corrosion resistance of solar cells, which can be tested for different environments including encapsulation.

  11. Standard Test Method for Measuring Heat-Transfer Rate Using a Thermal Capacitance (Slug) Calorimeter

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method describes the measurement of heat transfer rate using a thermal capacitance-type calorimeter which assumes one-dimensional heat conduction into a cylindrical piece of material (slug) with known physical properties. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. Note 1—For information see Test Methods E 285, E 422, E 458, E 459, and E 511.

  12. Further comments on the sequential probability ratio testing methods

    Energy Technology Data Exchange (ETDEWEB)

    Kulacsy, K. [Hungarian Academy of Sciences, Budapest (Hungary). Central Research Inst. for Physics

    1997-05-23

    The Bayesian method for belief updating proposed in Racz (1996) is examined. The interpretation of the belief function introduced therein is found, and the method is compared to the classical binary Sequential Probability Ratio Testing method (SPRT). (author).

  13. Test cases for interface tracking methods: methodology and current status

    International Nuclear Information System (INIS)

    Lebaigue, O.; Jamet, D.; Lemonnier, E.

    2004-01-01

    Full text of publication follows:In the past decade, a large number of new methods have been developed to deal with interfaces in the numerical simulation of two-phase flows. We have collected a set of 36 test cases, which can be seen as a tool to help engineers and researchers selecting the most appropriate method(s) for their specific fields of application. This set can be use: - To perform an initial evaluation of the capabilities of available methods with regard to the specificity of the final application and the most important features to be recovered from the simulation. - To measure the maximum mesh size to be used for a given physical problem in order to obtain an accurate enough solution. - To assess and quantify the performances of a selected method equipped with its set of physical models. The computation of a well-documented test case allows estimating the error due to the numerical technique by comparison with reference solutions. This process is compulsory to gain confidence and credibility on the prediction capabilities of a numerical method and its physical models. - To broaden the capabilities of a given numerical technique. The test cases may be used to identify the need for improvement of the overall numerical scheme or to determine the physical part of the model, which is responsible for the observed limitations. Each test case falls within one of the following categories: - Analytical solutions of well-known sets of equations corresponding to simple geometrical situations. - Reference numerical solutions of moderately complex problems, produced by accurate methods (e.g., boundary Fitted coordinate method) on refined meshes. - Separate effects analytical experiments. The presentation will suggest how to use the test cases for assessing the physical models and the numerical methods. The expected fallout of using test cases is indeed on the one hand to identify the merits of existing methods and on the other hand to orient further research towards

  14. Test methods for protective footwear against AP mine blast

    NARCIS (Netherlands)

    Cronin, D.S.; Williams, K.; Bass, C.R.; Magnan, P.; Dosquet, F.; Bergeron, D.M.; Bree, J.L.M.J. van

    2003-01-01

    The testing and development of protective footwear for anti-personnel landmine blast threats is of great importance to civilian and military deminers, and peacekeepers. This study will review the wide range of test methods that have been developed by NATO countries to test footwear against the

  15. Standardization of waste acceptance test methods by the Materials Characterization Center

    International Nuclear Information System (INIS)

    Slate, S.C.

    1985-01-01

    This paper describes the role of standardized test methods in demonstrating the acceptability of high-level waste (HLW) forms for disposal. Key waste acceptance tests are standardized by the Materials Characterization Center (MCC), which the US Department of Energy (DOE) has established as the central agency in the United States for the standardization of test methods for nuclear waste materials. This paper describes the basic three-step process that is used to show that waste is acceptable for disposal and discusses how standardized tests are used in this process. Several of the key test methods and their areas of application are described. Finally, future plans are discussed for using standardized tests to show waste acceptance. 9 refs., 1 tab

  16. Standard Test Method for Measuring Binocular Disparity in Transparent Parts

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the amount of binocular disparity that is induced by transparent parts such as aircraft windscreens, canopies, HUD combining glasses, visors, or goggles. This test method may be applied to parts of any size, shape, or thickness, individually or in combination, so as to determine the contribution of each transparent part to the overall binocular disparity present in the total “viewing system” being used by a human operator. 1.2 This test method represents one of several techniques that are available for measuring binocular disparity, but is the only technique that yields a quantitative figure of merit that can be related to operator visual performance. 1.3 This test method employs apparatus currently being used in the measurement of optical angular deviation under Method F 801. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not con...

  17. Development and Validation of a Dissolution Test Method for ...

    African Journals Online (AJOL)

    Purpose: To develop and validate a dissolution test method for dissolution release of artemether and lumefantrine from tablets. Methods: A single dissolution method for evaluating the in vitro release of artemether and lumefantrine from tablets was developed and validated. The method comprised of a dissolution medium of ...

  18. Radiative transfer with finite elements. Pt. 1. Basic method and tests

    Energy Technology Data Exchange (ETDEWEB)

    Richling, S. [Heidelberg Univ. (Germany). Inst. fuer Theoretische Astrophysik; Meinkoehn, E. [Heidelberg Univ. (Germany). Inst. fuer Theoretische Astrophysik]|[Heidelberg Univ. (Germany). Inst. fuer Angewandte Mathematik; Kryzhevoi, N. [Heidelberg Univ. (Germany). Inst. fuer Theoretische Astrophysik]|[Heidelberg Univ. (DE). Interdisziplinaeres Zentrum fuer Wissenschaftliches Rechnen (IWR); Kanschat, G. [Heidelberg Univ. (Germany). Inst. fuer Angewandte Mathematik]|[Heidelberg Univ. (DE). Interdisziplinaeres Zentrum fuer Wissenschaftliches Rechnen (IWR)

    2001-10-01

    A finite element method for solving the monochromatic radiation transfer equation including scattering in three dimensions is presented. The algorithm employs unstructured grids which are adaptively refined. Adaptivity as well as ordinate parallelization reduce memory requirements and execution time and make it possible to calculate the radiation field across several length scales for objects with strong opacity gradients. An a posteriori error estimate for one particular quantity is obtained by solving the dual problem. The application to a sample of test problems reveals the properties of the implementation. (orig.)

  19. Earthquake analysis of structures including structure-soil interaction by a substructure method

    International Nuclear Information System (INIS)

    Chopra, A.K.; Guttierrez, J.A.

    1977-01-01

    A general substructure method for analysis of response of nuclear power plant structures to earthquake ground motion, including the effects of structure-soil interaction, is summarized. The method is applicable to complex structures idealized as finite element systems and the soil region treated as either a continuum, for example as a viscoelastic halfspace, or idealized as a finite element system. The halfspace idealization permits reliable analysis for sites where essentially similar soils extend to large depths and there is no rigid boundary such as soil-rock interface. For sites where layers of soft soil are underlain by rock at shallow depth, finite element idealization of the soil region is appropriate; in this case, the direct and substructure methods would lead to equivalent results but the latter provides the better alternative. Treating the free field motion directly as the earthquake input in the substructure eliminates the deconvolution calculations and the related assumption-regarding type and direction of earthquake waves-required in the direct method. (Auth.)

  20. Solar panel thermal cycling testing by solar simulation and infrared radiation methods

    Science.gov (United States)

    Nuss, H. E.

    1980-01-01

    For the solar panels of the European Space Agency (ESA) satellites OTS/MAROTS and ECS/MARECS the thermal cycling tests were performed by using solar simulation methods. The performance data of two different solar simulators used and the thermal test results are described. The solar simulation thermal cycling tests for the ECS/MARECS solar panels were carried out with the aid of a rotatable multipanel test rig by which simultaneous testing of three solar panels was possible. As an alternative thermal test method, the capability of an infrared radiation method was studied and infrared simulation tests for the ultralight panel and the INTELSAT 5 solar panels were performed. The setup and the characteristics of the infrared radiation unit using a quartz lamp array of approx. 15 sq and LN2-cooled shutter and the thermal test results are presented. The irradiation uniformity, the solar panel temperature distribution, temperature changing rates for both test methods are compared. Results indicate the infrared simulation is an effective solar panel thermal testing method.

  1. Evaluation of PDA Technical Report No 33. Statistical Testing Recommendations for a Rapid Microbiological Method Case Study.

    Science.gov (United States)

    Murphy, Thomas; Schwedock, Julie; Nguyen, Kham; Mills, Anna; Jones, David

    2015-01-01

    New recommendations for the validation of rapid microbiological methods have been included in the revised Technical Report 33 release from the PDA. The changes include a more comprehensive review of the statistical methods to be used to analyze data obtained during validation. This case study applies those statistical methods to accuracy, precision, ruggedness, and equivalence data obtained using a rapid microbiological methods system being evaluated for water bioburden testing. Results presented demonstrate that the statistical methods described in the PDA Technical Report 33 chapter can all be successfully applied to the rapid microbiological method data sets and gave the same interpretation for equivalence to the standard method. The rapid microbiological method was in general able to pass the requirements of PDA Technical Report 33, though the study shows that there can be occasional outlying results and that caution should be used when applying statistical methods to low average colony-forming unit values. Prior to use in a quality-controlled environment, any new method or technology has to be shown to work as designed by the manufacturer for the purpose required. For new rapid microbiological methods that detect and enumerate contaminating microorganisms, additional recommendations have been provided in the revised PDA Technical Report No. 33. The changes include a more comprehensive review of the statistical methods to be used to analyze data obtained during validation. This paper applies those statistical methods to analyze accuracy, precision, ruggedness, and equivalence data obtained using a rapid microbiological method system being validated for water bioburden testing. The case study demonstrates that the statistical methods described in the PDA Technical Report No. 33 chapter can be successfully applied to rapid microbiological method data sets and give the same comparability results for similarity or difference as the standard method. © PDA, Inc

  2. Standard test method for distribution coefficients of inorganic species by the batch method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the determination of distribution coefficients of chemical species to quantify uptake onto solid materials by a batch sorption technique. It is a laboratory method primarily intended to assess sorption of dissolved ionic species subject to migration through pores and interstices of site specific geomedia. It may also be applied to other materials such as manufactured adsorption media and construction materials. Application of the results to long-term field behavior is not addressed in this method. Distribution coefficients for radionuclides in selected geomedia are commonly determined for the purpose of assessing potential migratory behavior of contaminants in the subsurface of contaminated sites and waste disposal facilities. This test method is also applicable to studies for parametric studies of the variables and mechanisms which contribute to the measured distribution coefficient. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement a...

  3. Standard test method for liquid impingement erosion using rotating apparatus

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers tests in which solid specimens are eroded or otherwise damaged by repeated discrete impacts of liquid drops or jets. Among the collateral forms of damage considered are degradation of optical properties of window materials, and penetration, separation, or destruction of coatings. The objective of the tests may be to determine the resistance to erosion or other damage of the materials or coatings under test, or to investigate the damage mechanisms and the effect of test variables. Because of the specialized nature of these tests and the desire in many cases to simulate to some degree the expected service environment, the specification of a standard apparatus is not deemed practicable. This test method gives guidance in setting up a test, and specifies test and analysis procedures and reporting requirements that can be followed even with quite widely differing materials, test facilities, and test conditions. It also provides a standardized scale of erosion resistance numbers applicab...

  4. Standard test methods for analysis of sintered gadolinium oxide-uranium dioxide pellets

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 These test methods cover procedures for the analysis of sintered gadolinium oxide-uranium dioxide pellets to determine compliance with specifications. 1.2 The analytical procedures appear in the following order: Section Carbon (Total) by Direct CombustionThermal Conductivity Method C1408 Test Method for Carbon (Total) in Uranium Oxide Powders and Pellets By Direct Combustion-Infrared Detection Method Chlorine and Fluorine by Pyrohydrolysis Ion-Selective Electrode Method C1502 Test Method for Determination of Total Chlorine and Fluorine in Uranium Dioxide and Gadolinium Oxide Gadolinia Content by Energy-Dispersive X-Ray Spectrometry C1456 Test Method for Determination of Uranium or Gadolinium, or Both, in Gadolinium Oxide-Uranium Oxide Pellets or by X-Ray Fluorescence (XRF) Hydrogen by Inert Gas Fusion C1457 Test Method for Determination of Total Hydrogen Content of Uranium Oxide Powders and Pellets by Carrier Gas Extraction Isotopic Uranium Composition by Multiple-Filament Surface-Ioni...

  5. Integrated circuit test-port architecture and method and apparatus of test-port generation

    Science.gov (United States)

    Teifel, John

    2016-04-12

    A method and apparatus are provided for generating RTL code for a test-port interface of an integrated circuit. In an embodiment, a test-port table is provided as input data. A computer automatically parses the test-port table into data structures and analyzes it to determine input, output, local, and output-enable port names. The computer generates address-detect and test-enable logic constructed from combinational functions. The computer generates one-hot multiplexer logic for at least some of the output ports. The one-hot multiplexer logic for each port is generated so as to enable the port to toggle between data signals and test signals. The computer then completes the generation of the RTL code.

  6. Methods and models for the construction of weakly parallel tests

    NARCIS (Netherlands)

    Adema, J.J.; Adema, Jos J.

    1992-01-01

    Several methods are proposed for the construction of weakly parallel tests [i.e., tests with the same test information function (TIF)]. A mathematical programming model that constructs tests containing a prespecified TIF and a heuristic that assigns items to tests with information functions that are

  7. Standard Test Method for Hydrophobic Surface Films by the Atomizer Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1965-01-01

    1.1 This test method covers the detection of the presence of hydrophobic (nonwetting) films on surfaces and the presence of hydrophobic organic materials in processing ambients. When properly conducted, the test will enable detection of fractional molecular layers of hydrophobic organic contaminants. On very rough or porous surfaces the sensitivity of the test may be significantly decreased. 1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  8. A Fuzzy Logic Based Method for Analysing Test Results

    Directory of Open Access Journals (Sweden)

    Le Xuan Vinh

    2017-11-01

    Full Text Available Network operators must perform many tasks to ensure smooth operation of the network, such as planning, monitoring, etc. Among those tasks, regular testing of network performance, network errors and troubleshooting is very important. Meaningful test results will allow the operators to evaluate network performanceof any shortcomings and to better plan for network upgrade. Due to the diverse and mainly unquantifiable nature of network testing results, there is a needs to develop a method for systematically and rigorously analysing these results. In this paper, we present STAM (System Test-result Analysis Method which employs a bottom-up hierarchical processing approach using Fuzzy logic. STAM is capable of combining all test results into a quantitative description of the network performance in terms of network stability, the significance of various network erros, performance of each function blocks within the network. The validity of this method has been successfully demonstrated in assisting the testing of a VoIP system at the Research Instiute of Post and Telecoms in Vietnam. The paper is organized as follows. The first section gives an overview of fuzzy logic theory the concepts of which will be used in the development of STAM. The next section describes STAM. The last section, demonstrating STAM’s capability, presents a success story in which STAM is successfully applied.

  9. 77 FR 4544 - CPSC Symposium on Phthalates Screening and Testing Methods

    Science.gov (United States)

    2012-01-30

    ... Screening and Testing Methods AGENCY: Consumer Product Safety Commission. ACTION: Notice. SUMMARY: The... symposium on phthalates screening and testing methods. The symposium will be held at the CPSC's National... submit comments, identified by Docket No. CPSC-2012-0008, by any of the following methods: Electronic...

  10. An accelerated test method for efflorescence in clay bricks

    International Nuclear Information System (INIS)

    Beggan, John Edward

    1998-01-01

    An investigation into the creation of accelerated efflorescence in clay bricks was undertaken with a view to creating a viable test procedure for determining efflorescence potential. The testing programme incorporated ambient conditions similar to those which promote efflorescence growth in bricks in use. Theoretical investigations into the physical mechanism underlying the creation of efflorescence directed the attempts to accelerate the process. It was found that calcium sulphate efflorescence could not be sufficiently accelerated such that a useful efflorescence test procedure could be proposed. The inability to produce accelerated efflorescence in brick samples was attributed to limitations associated with time dependent salt diffusion in the efflorescence mechanism. The preliminary testing that was undertaken into the creation of efflorescence prompted the use of acid assisted methods to accelerate efflorescence. The acid assisted method that was adopted to provide a possible indication of efflorescence potential relies upon the transformation of low solubility calcium to a more soluble form. The movement of the transformed salt is then induced by cyclic temperature exposure at temperatures similar to those experienced in Spring. The appearance of the transformed calcium salt on the surface of the brick specimen provides an indication of the efflorescence potential. Brick piers constructed on an exposed site and monitored over a 12 month period provided information on the validity of the acid assisted test method. The efflorescence observed on the piers correlated well with that predicted by the acid assisted test, suggesting that the new test has the potential to accurately predict the efflorescence potential of clay bricks Relationships between other properties such as air permeability, sorptivity and tensile strength were investigated such that an alternative method of predicting efflorescence could be achieved. It was found that (within the bounds of the

  11. Intercomparison of leach-testing methods and the effects of waste-form composition on test type and duration

    International Nuclear Information System (INIS)

    Harvey, K.B.; Jensen, C.D.

    1982-01-01

    Several leach-testing methods were evaluated for their relevance as scoping tests appropriate to proposed Canadian conditions for the disposal of high-level nuclear waste, and a static, terminated leach test was chosen. For a particular glass composition, methods in which the leachant was replenished gave apparent leach rates up to ten times less than did the static test. Under static leaching conditions, the leach rate of a number of sodium borosilicate glasses was observed to first rise and then fall with leaching time. This behavior is explained in terms of a pH change in the leachant, which is itself a function of the glass composition. The implications of these observations on glass compositions and on leach-testing methods that are relevant to the needs of final disposal are briefly discussed

  12. Seismic testing

    International Nuclear Information System (INIS)

    Sollogoub, Pierre

    2001-01-01

    This lecture deals with: qualification methods for seismic testing; objectives of seismic testing; seismic testing standards including examples; main content of standard; testing means; and some important elements of seismic testing

  13. A simple and cost-effective method of DNA extraction from small formalin-fixed paraffin-embedded tissue for molecular oncologic testing.

    Science.gov (United States)

    Snow, Anthony N; Stence, Aaron A; Pruessner, Jonathan A; Bossler, Aaron D; Ma, Deqin

    2014-01-01

    Extraction of DNA from formalin-fixed, paraffin-embedded (FFPE) tissue is a critical step in molecular oncologic testing. As molecular oncology testing becomes more important for prognostic and therapeutic decision making and tissue specimens become smaller due to earlier detection of suspicious lesions and the use of fine needle aspiration methods for tissue collection, it becomes more challenging for the typical molecular pathology laboratory to obtain reliable test results. We developed a DNA extraction method to obtain sufficient quantity and high quality genomic DNA from limited FFPE tissue for molecular oncology testing using a combination of H&E stained slides, a matrix capture method and the Qiagen DNA column. THREE DNA EXTRACTION METHODS WERE COMPARED: our standard procedure of manually scraping tissue from unstained slides followed by DNA extraction using the QIAamp FFPE column (Qiagen, Valencia, CA), a glue capture method (Pinpoint Solution, Zymo Research Corp, Inc) on H&E stained slides followed by DNA extraction using either the QIAamp column or the column included with the Pinpoint kit (Zymo Research). The DNA extraction protocol was optimized. Statistical analysis was performed using the paired two-sample student's t-test. The combination of the matrix capture method with the QIAamp column gave an equivalent amount of DNA as our standard extraction method using the unstained slides and a 4.6-fold higher DNA yield than using the Zymo column included in the Pinpoint Slide Solution kit. Several molecular tests were performed and DNA purified using the new method gave the same results as for the previous methods. Using H&E stained slides allows visual confirmation of tumor cells during microdissection. The Pinpoint solution made removal of specific tissue from the slides easier and reduced the risk of contamination and tissue loss. This DNA extraction method is simple, cost-effective, and blends with our current workflow requiring no additional equipment.

  14. Review of Test Theory and Methods.

    Science.gov (United States)

    1981-01-01

    literature, although some books , technical reports, and unpub- lished literature have been included where relevant. The focus of the review is on practical...1977) and Abu-Sayf (1977) developed new versions of formula scores, and Molenaar (1977) took a Bayesian approach to correcting for random guessing. The...Snow’s (1977) book on aptitude and instructional methods is a landmark review of the research on the interaction between instructional methods and

  15. 40 CFR 63.750 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... method in production on actual production parts or assemblies for a period of time sufficient to coat an... a laboratory or pilot production area, using parts and coatings representative of the process(es) where the alternative method is to be used. The laboratory test will use the same part configuration(s...

  16. 40 CFR 63.1257 - Test methods and compliance procedures.

    Science.gov (United States)

    2010-07-01

    ... chemical engineering principles, measurable process parameters, or physical or chemical laws or properties... flow rate and concentration; temperature; and the reaction kinetics of the constituents with the... Method 8260 or 8270 in “Test Methods for Evaluating Solid Waste, Physical/Chemical Methods,” EPA...

  17. An analytic data analysis method for oscillatory slug tests.

    Science.gov (United States)

    Chen, Chia-Shyun

    2006-01-01

    An analytical data analysis method is developed for slug tests in partially penetrating wells in confined or unconfined aquifers of high hydraulic conductivity. As adapted from the van der Kamp method, the determination of the hydraulic conductivity is based on the occurrence times and the displacements of the extreme points measured from the oscillatory data and their theoretical counterparts available in the literature. This method is applied to two sets of slug test response data presented by Butler et al.: one set shows slow damping with seven discernable extremities, and the other shows rapid damping with three extreme points. The estimates of the hydraulic conductivity obtained by the analytic method are in good agreement with those determined by an available curve-matching technique.

  18. Linear shrinkage test: justification for its reintroduction as a standard South African test method

    CSIR Research Space (South Africa)

    Sampson, LR

    2009-06-04

    Full Text Available Several problems with the linear shrinkage test specified in Method A4 of the THM 1 1979 were addressed as part of this investigation in an effort to improve the alleged poor reproducibility of the test and justify its reintroduction into THM 1. A...

  19. 40 CFR 63.425 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... maximum allowable 5-minute pressure increase is 130 mm H2 O (5 in. H2 O). (f) Leak detection test. The leak detection test shall be performed using Method 21, appendix A, 40 CFR part 60, except omit section... between each leak detection. The duration of the purge shall be in excess of two instrument response times...

  20. Practical test set-up and method for determining the response characteristics of a log rate channel over 6 decades

    International Nuclear Information System (INIS)

    Kemp, J.

    1996-01-01

    A test method was developed using modern, readily available instrumentation to produce an exponentially rising signal over 6 1/2 decades. The method includes validation and calibration tests. It was used to simulate the current signal that would be produced from an ion chamber during a hypothetical loss of Regulation event for a reactor from a shutdown state. This simulation scenario was then used to test the log rate channel of the new ion chamber amplifiers for the NRU research reactor second trip system upgrade. (author)

  1. TESTING METHODS FOR MECHANICALLY IMPROVED SOILS: RELIABILITY AND VALIDITY

    Directory of Open Access Journals (Sweden)

    Ana Petkovšek

    2017-10-01

    Full Text Available A possibility of in-situ mechanical improvement for reducing the liquefaction potential of silty sands was investigated by using three different techniques: Vibratory Roller Compaction, Rapid Impact Compaction (RIC and Soil Mixing. Material properties at all test sites were investigated before and after improvement with the laboratory and the in situ tests (CPT, SDMT, DPSH B, static and dynamic load plate test, geohydraulic tests. Correlation between the results obtained by different test methods gave inconclusive answers.

  2. Comparison of manual mycobacteria growth indicator tube and epsilometer test with agar proportion method for susceptibility testing of Mycobacterium tuberculosis

    Directory of Open Access Journals (Sweden)

    N Karabulut

    2014-01-01

    Full Text Available Background and Objectives: Antimycobacterial susceptibility tests take weeks, and delayed therapy can lead to spread of Mycobacterium tuberculosis. Therefore, rapid, accurate and cost-effective methods are required for proper therapy selection. In this study, the Mycobacteria growth indicator tube (MGIT and epsilometer test (Etest methods were compared to the agar proportion method for susceptibility testing of Mycobacterium tuberculosis. Materials and Methods: The susceptibility tests against isoniazid (INH, rifampin (RIF, streptomycin (STM and ethambutol (ETM of 51 M. tuberculosis complex isolates were analyzed by the MGIT, Etest and agar proportion methods. Results: The concordance between MGIT/Etest and agar proportion methods was 98% for INH and 100% for RIF, STM, ETM. There were not statistically significant differences in results of the susceptibility tests between MGIT/Etest and the reference agar proportion method. Conclusion: The results have shown that MGIT and Etest methods can be used instead of the agar proportion method, because these two methods are more rapid and easier than the agar proportion method.

  3. Impact Strength of Natural Fibre Composites Measured by Different Test Methods: A Review

    Directory of Open Access Journals (Sweden)

    Navaranjan Namasivayam

    2017-01-01

    Full Text Available Different types of impact test methods have been used in recent years to measure the impact resistance of natural fibre composites (NFCs. After reviewing the literature, the impact resistance of flax, hemp, sisal, wood and jute fibre composites that were measured using different test methods have been compared and discussed. It has been learned that the test methods were selected for research interest, industry requirement or availability of test equipment. Each method had its own advantages and limitations. The result from a particular test could be compared but not with the result from other test methods. Most impact test methods were developed for testing ductile-brittle transition of metals. However, each NFC has a different morphology and cannot be comparable to metals in failure mode and energy absorption characteristic during an impact test. A post evaluation of morphology of an NFC sample after an impact test is important to characterise the material.

  4. Feasibility of supervised self-testing using an oral fluid-based HIV rapid testing method: a cross-sectional, mixed method study among pregnant women in rural India

    OpenAIRE

    Sarkar, Archana; Mburu, Gitau; Shivkumar, Poonam Varma; Sharma, Pankhuri; Campbell, Fiona; Behera, Jagannath; Dargan, Ritu; Mishra, Surendra Kumar; Mehra, Sunil

    2016-01-01

    Introduction: HIV self-testing can increase coverage of essential HIV services. This study aimed to establish the acceptability, concordance and feasibility of supervised HIV self-testing among pregnant women in rural India. Methods: A cross-sectional, mixed methods study was conducted among 202 consenting pregnant women in a rural Indian hospital between August 2014 and January 2015. Participants were provided with instructions on how to self-test using OraQuick® HIV antibody test, and subse...

  5. Standard test method for exfoliation corrosion susceptibility in 2XXX and 7XXX Series Aluminum Alloys (EXCO Test)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method covers a procedure for constant immersion exfoliation corrosion (EXCO) testing of high-strength 2XXX and 7XXX series aluminum alloys. Note 1—This test method was originally developed for research and development purposes; however, it is referenced, in specific material specifications, as applicable for evaluating production material (refer to Section 14 on Precision and Bias). 1.2 This test method applies to all wrought products such as sheet, plate, extrusions, and forgings produced from conventional ingot metallurgy process. 1.3 This test method can be used with any form of specimen or part that can be immersed in the test solution. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  6. Nondestructive testing method for a new generation of electronics

    Directory of Open Access Journals (Sweden)

    Azin Anton

    2018-01-01

    Full Text Available The implementation of the Smart City system needs reliable and smoothly operating electronic equipment. The study is aimed at developing a nondestructive testing method for electronic equipment and its components. This method can be used to identify critical design defects of printed circuit boards (PCB and to predict their service life, taking into account the nature of probable operating loads. The study uses an acoustic emission method to identify and localize critical design defects of printed circuit boards. Geometric dimensions of detected critical defects can be determined by the X-ray tomography method. Based on the results of the study, a method combining acoustic emission and X-ray tomography was developed for nondestructive testing of printed circuit boards. The stress-strain state of solder joints containing detected defects was analyzed. This paper gives an example of using the developed method for estimating the degree of damage to joints between PCB components and predicting the service life of the entire PCB.

  7. Comparative study of heuristic evaluation and usability testing methods.

    Science.gov (United States)

    Thyvalikakath, Thankam Paul; Monaco, Valerie; Thambuganipalle, Himabindu; Schleyer, Titus

    2009-01-01

    Usability methods, such as heuristic evaluation, cognitive walk-throughs and user testing, are increasingly used to evaluate and improve the design of clinical software applications. There is still some uncertainty, however, as to how those methods can be used to support the development process and evaluation in the most meaningful manner. In this study, we compared the results of a heuristic evaluation with those of formal user tests in order to determine which usability problems were detected by both methods. We conducted heuristic evaluation and usability testing on four major commercial dental computer-based patient records (CPRs), which together cover 80% of the market for chairside computer systems among general dentists. Both methods yielded strong evidence that the dental CPRs have significant usability problems. An average of 50% of empirically-determined usability problems were identified by the preceding heuristic evaluation. Some statements of heuristic violations were specific enough to precisely identify the actual usability problem that study participants encountered. Other violations were less specific, but still manifested themselves in usability problems and poor task outcomes. In this study, heuristic evaluation identified a significant portion of problems found during usability testing. While we make no assumptions about the generalizability of the results to other domains and software systems, heuristic evaluation may, under certain circumstances, be a useful tool to determine design problems early in the development cycle.

  8. The research of the test-class method based on interface object in the software integration test of the large container inspection system

    International Nuclear Information System (INIS)

    Sun Shaohua; Chen Zhiqiang; Zhang Li; Gao Wenhuan; Kang Kejun

    2000-01-01

    Software test is the important stage in software process. The has been mature theory, method and model for unit test in practice. But for integration test, there is not regular method to adhere to. The author presents a new method, developed during the development of the large container inspection system, named test class method based on interface object. In this method a set of basic test-class based on the concept of class in the object-oriented method is established and the method of combining the interface graph and the class set is used to describe the test process. So the strict control and the scientific management for the test process are achieved. The conception of test database is introduced in this method, thus the traceability and the repeatability of test process are improved

  9. Evaluation of rapid radiometric method for drug susceptibility testing of Mycobacterium tuberculosis

    International Nuclear Information System (INIS)

    Siddiqi, S.H.; Libonati, J.P.; Middlebrook, G.

    1981-01-01

    A total of 106 isolates of Mycobacterium tuberculosis were tested for drug susceptibility by the conventional 7H11 plate method and by a new rapid radiometric method using special 7H12 liquid medium with 14 C-labeled substrate. Results obtained by the two methods were compared for rapidity, sensitivity, and specificity of the new test method. There was 98% overall agreement between the results obtained by the two methods. Of a total of 424 drug tests, only 8 drug results did not agree, mostly in the case of streptomycin. This new procedure was found to be rapid, with 87% of the tests results reportable within 4 days and 98% reportable within 5 days as compared to the usual 3 weeks required with the conventional indirect susceptibility test method. The results of this preliminary study indicate that the rapid radiometric method seems to have the potential for routine laboratory use and merits further investigations

  10. Comparison and clinical utility evaluation of four multiple allergen simultaneous tests including two newly introduced fully automated analyzers

    Directory of Open Access Journals (Sweden)

    John Hoon Rim

    2016-04-01

    Full Text Available Background: We compared the diagnostic performances of two newly introduced fully automated multiple allergen simultaneous tests (MAST analyzers with two conventional MAST assays. Methods: The serum samples from a total of 53 and 104 patients were tested for food panels and inhalant panels, respectively, in four analyzers including AdvanSure AlloScreen (LG Life Science, Korea, AdvanSure Allostation Smart II (LG Life Science, PROTIA Allergy-Q (ProteomeTech, Korea, and RIDA Allergy Screen (R-Biopharm, Germany. We compared not only the total agreement percentages but also positive propensities among four analyzers. Results: Evaluation of AdvanSure Allostation Smart II as upgraded version of AdvanSure AlloScreen revealed good concordance with total agreement percentages of 93.0% and 92.2% in food and inhalant panel, respectively. Comparisons of AdvanSure Allostation Smart II or PROTIA Allergy-Q with RIDA Allergy Screen also showed good concordance performance with positive propensities of two new analyzers for common allergens (Dermatophagoides farina and Dermatophagoides pteronyssinus. The changes of cut-off level resulted in various total agreement percentage fluctuations among allergens by different analyzers, although current cut-off level of class 2 appeared to be generally suitable. Conclusions: AdvanSure Allostation Smart II and PROTIA Allergy-Q presented favorable agreement performances with RIDA Allergy Screen, although positive propensities were noticed in common allergens. Keywords: Multiple allergen simultaneous test, Automated analyzer

  11. Critical wall shear stress for the EHEDG test method

    DEFF Research Database (Denmark)

    Jensen, Bo Boye Busk; Friis, Alan

    2004-01-01

    In order to simulate the results of practical cleaning tests on closed processing equipment, based on wall shear stress predicted by computational fluid dynamics, a critical wall shear stress is required for that particular cleaning method. This work presents investigations that provide a critical...... wall shear stress of 3 Pa for the standardised EHEDG cleaning test method. The cleaning tests were performed on a test disc placed in a radial flowcell assay. Turbulent flow conditions were generated and the corresponding wall shear stresses were predicted from CFD simulations. Combining wall shear...... stress predictions from a simulation using the low Re k-epsilon and one using the two-layer model of Norris and Reynolds were found to produce reliable predictions compared to empirical solutions for the ideal flow case. The comparison of wall shear stress curves predicted for the real RFC...

  12. Standard test method for laboratory evaluation of magnesium sacrificial anode test specimens for underground applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers a laboratory procedure that measures the two fundamental performance properties of magnesium sacrificial anode test specimens operating in a saturated calcium sulfate, saturated magnesium hydroxide environment. The two fundamental properties are electrode (oxidation potential) and ampere hours (Ah) obtained per unit mass of specimen consumed. Magnesium anodes installed underground are usually surrounded by a backfill material that typically consists of 75 % gypsum (CaSO4·2H2O), 20 % bentonite clay, and 5 % sodium sulfate (Na2SO4). The calcium sulfate, magnesium hydroxide test electrolyte simulates the long term environment around an anode installed in the gypsum-bentonite-sodium sulfate backfill. 1.2 This test method is intended to be used for quality assurance by anode manufacturers or anode users. However, long term field performance properties may not be identical to property measurements obtained using this laboratory test. Note 1—Refer to Terminology G 15 for terms used ...

  13. A new 3D reconstituted human corneal epithelium model as an alternative method for the eye irritation test.

    Science.gov (United States)

    Jung, Kyoung-Mi; Lee, Su-Hyon; Ryu, Yang-Hwan; Jang, Won-Hee; Jung, Haeng-Sun; Han, Ju-Hee; Seok, Seung-Hyeok; Park, Jae-Hak; Son, Youngsook; Park, Young-Ho; Lim, Kyung-Min

    2011-02-01

    Many efforts are being made to develop new alternative in vitro test methods for the eye irritation test. Here we report a new reconstructed human corneal epithelial model (MCTT HCE model) prepared from primary-cultured human limbal epithelial cells as a new alternative in vitro eye irritation test method. In histological and immunohistochemical observation, MCTT HCE model displayed a morphology and biomarker expressions similar to intact human cornea. Moreover, the barrier function was well preserved as measured by high transepithelial electrical resistance, effective time-50 for Triton X-100, and corneal thickness. To employ the model as a new alternative method for eye irritation test, protocol refinement was performed and optimum assay condition was determined including treatment time, treatment volume, post-incubation time and rinsing method. Using the refined protocol, 25 reference chemicals with known eye irritation potentials were tested. With the viability cut-off value at 50%, chemicals were classified to irritant or non-irritant. When compared with GHS classification, the MCTT HCE model showed the accuracy of 88%, sensitivity of 100% and specificity of 77%. These results suggest that the MCTT HCE model might be useful as a new alternative eye irritation test method. Copyright © 2010 Elsevier Ltd. All rights reserved.

  14. Non-destructive vacuum decay method for pre-filled syringe closure integrity testing compared with dye ingress testing and high-voltage leak detection.

    Science.gov (United States)

    Simonetti, Andrea; Amari, Filippo

    2015-01-01

    solution, preventing possible prefilled syringe plunger movement during container closure integrity testing execution, is presented as well. The growing need to meet sterile drug products' regulatory, quality, and safety expectations has progressively driven new developments and improvements both in container closure integrity testing methods and in the respective equipment, over the last years. Indeed, container closure integrity testing establishes the container closure system capability to provide required protection to the drug product and to demonstrate maintenance of product sterility over its shelf life. This article describes the development of four container closure integrity testing approaches for the evaluation of glass prefilled syringe closure integrity, including two destructive (pharmacopoeial and Novartis specific dye ingress test) and two non-destructive (vacuum decay and high-voltage leak detection) methods. The important finding from the validation of comparative studies was that the vacuum decay method resulted in the most effective, reliable and repeatable detection of defective samples, whether the defect was exposed to sterile water, to drug product, or to air. Complete sets of known defects were created for this purpose (5 μm, 10 μm, 20 μm certified leakages by laser drilled holes and capillary tubes). All investigations and studies were conducted at Bonfiglioli Engineering S.r.l. (Vigarano Pieve, Ferrara, Italy) and at Novartis Vaccines (Sovicille, Siena, Italy). © PDA, Inc. 2015.

  15. CONSTOR registered V/TC drop tests. Pre-test analysis by finite element method

    International Nuclear Information System (INIS)

    Voelzer, W.; Koenig, S.; Klein, K.; Tso, C.F.; Owen, S.; Monk, C.

    2004-01-01

    The CONSTOR registered family of steel-concrete-steel sandwich cask designs have been developed to fulfil both the internationally valid IAEA criteria for transportation and the requirements for long-term intermediate storage in the US and various European countries. A comprehensive drop testing programme using a full-scale prototype test cask (CONSTOR registered V/TC) has been developed as part of the application for a transport license in both Germany and the US. The drop tests using the full-scale cask will be performed by BAM at test facilities in Horstwalde. The tests will include five different 9m drops onto flat unyielding targets and seven different 1m drops onto a punch. The first drop test, a 9m side drop, will be performed during PATRAM 2004. The other drop tests will take place during the following year. The development of the cask design and the formulation of the drop test programme has been supported by an extensive series of finite element analyses. The objectives of the finite element analyses were; to provide an intermediate step in demonstrating the performance of the CONSTOR registered in fulfilling the requirements of 10 CFR 71 and the IAEA transport regulations. To justify the selection of drop tests. To predict the performance of V/TC during the drop tests. To estimate the strain and acceleration time histories at measuring points on the test cask and to aid in the setting up of the test instrumentation. To develop an analysis model that can be used in future safety analyses for transport and storage license applications and which can confidently be used to demonstrate the performance of the package. This paper presents an overview of the analyses performed, including a summary of all the different drop orientations that were considered. The major assumptions employed during the analyses are also discussed, as are the specifics of the modelling techniques that were employed. At the end of the paper, the key results obtained from the analyses

  16. A novel test tube method of screening for hemoglobin E.

    Science.gov (United States)

    Tatu, T; Kasinrerk, W

    2012-02-01

    Hemoglobin (Hb) E is a β-structural variant common worldwide. This Hb disorder can form a compound heterozygous state with the β-thalassemia gene, leading to life-threatening hereditary hemolytic anemia, HbE/β-thalassemia. Screening of HbE has proven to be a challenging practice in prevention and control of the HbE/β-thalassemia. A novel test tube method for HbE screening using diethyl aminoethyl (DEAE)-cellulose resin was described. With the developed system, HbE/A(2) did not bind to the resin and remained dissolved in the supernatant, whereas other Hbs completely bound to the resin. The red color of the supernatant observed in the test tube indicated the presence of HbE. Colorless or markedly pale color of the supernatant indicates the absence of HbE. Accuracy and efficiency of the established method in detecting HbE was comparable with the standard cellulose acetate electrophoresis method. The developed method is cheap and simple with no requirement of sophisticated equipment. The reagent could be stored at 4 °C for up to 5 months. Hemolysate samples aged up to 5 months were still suitable for this test. The described novel test tube method could be an alternative method of mass population screening for HbE, particularly in small health care facilities. © 2011 Blackwell Publishing Ltd.

  17. 40 CFR 60.46 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... material balance over the steam generating system shall be used to confirm the rate. (d) The owner or...-Fired Steam Generators for Which Construction Is Commenced After August 17, 1971 § 60.46 Test methods... D2015, or D5865 (solid fuels), D240 (liquid fuels), or D1826 (gaseous fuels) (all of these methods are...

  18. The research of the test-class method based on interface object in the software integration test of the large container inspection system

    International Nuclear Information System (INIS)

    Sun Shaohua; Chen Zhiqiang; Zhang Li; Gao Wenhuan; Kang Kejun

    2001-01-01

    Software test is the important stage in software process. There has been mature theory, method and model for unit test in practice. But for integration test, there is not regular method to adhere to. The author presents a new method, developed during the development of the large container inspection system, named test-class method based on interface object. A set of basis test-class based on the concept of class in the object-oriented method is established and the method of combining the interface graph and the class set is used to describe the test process. So the strict control and the scientific management for the test process are achieved. The conception of test database is introduced in this method, thus the traceability and the repeatability of test process are improved

  19. Standard test method for plane-strain (Chevron-Notch) fracture toughness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers the determination of plane-strain (chevron-notch) fracture toughnesses, KIv or KIvM, of metallic materials. Fracture toughness by this method is relative to a slowly advancing steady state crack initiated at a chevron-shaped notch, and propagating in a chevron-shaped ligament (Fig. 1). Some metallic materials, when tested by this method, exhibit a sporadic crack growth in which the crack front remains nearly stationary until a critical load is reached. The crack then becomes unstable and suddenly advances at high speed to the next arrest point. For these materials, this test method covers the determination of the plane-strain fracture toughness, KIvj or KIvM, relative to the crack at the points of instability. Note 1—One difference between this test method and Test Method E 399 (which measures KIc) is that Test Method E 399 centers attention on the start of crack extension from a fatigue precrack. This test method makes use of either a steady state slowly propagating crack, or a...

  20. Development of new testing methods for the numerical load analysis for the drop test of steel sheet containers for the final repository Konrad

    International Nuclear Information System (INIS)

    Protz, C.; Voelzke, H.; Zencker, U.; Hagenow, P.; Gruenewald, H.

    2011-01-01

    The qualification of steel sheet containers as intermediate-level waste container for the final repository is performed by the BAM (Bundeasmt fuer Materialpruefung) according to the BfS (Bundesamt fuer Strahlenschutz) requirements. The testing requirements include the stacking pressure tests, lifting tests, drop tests thermal tests (fire resistance) and tightness tests. Besides the verification using model or prototype tests and transferability considerations numerical safety analyses may be performed alternatively. The authors describe the internal BAM research project ConDrop aimed to develop extended testing methods for the drop test of steel sheet containers for the final repository Konrad using numerical load analyses. A finite element model was developed using The FE software LS-PrePost 3.0 and ANSYS 12.0 and the software FE-Code LS-DYNA for the simulation of the drop test (5 m height). The results were verified by experimental data from instrumented drop tests. The container preserves its integrity after the drop test, plastic deformation occurred at the bottom plate, the side walls, the cask cover and the lateral uprights.

  1. Analysis of Power Transfer Efficiency of Standard Integrated Circuit Immunity Test Methods

    Directory of Open Access Journals (Sweden)

    Hai Au Huynh

    2015-01-01

    Full Text Available Direct power injection (DPI and bulk current injection (BCI methods are defined in IEC 62132-3 and IEC 62132-4 as the electromagnetic immunity test method of integrated circuits (IC. The forward power measured at the RF noise generator when the IC malfunctions is used as the measure of immunity level of the IC. However, the actual power that causes failure in ICs is different from forward power measured at the noise source. Power transfer efficiency is used as a measure of power loss of the noise injection path. In this paper, the power transfer efficiencies of DPI and BCI methods are derived and validated experimentally with immunity test setup of a clock divider IC. Power transfer efficiency varies significantly over the frequency range as a function of the test method used and the IC input impedance. For the frequency range of 15 kHz to 1 GHz, power transfer efficiency of the BCI test was constantly higher than that of the DPI test. In the DPI test, power transfer efficiency is particularly low in the lower test frequency range up to 10 MHz. When performing the IC immunity tests following the standards, these characteristics of the test methods need to be considered.

  2. Developing a Standard Method of Test for Packaged, Solid-Desiccant Based Dehumidification Systems

    International Nuclear Information System (INIS)

    Sand, J.R.

    2001-01-01

    A draft Method of Test (MOT) has been proposed for packaged, air-to-air, desiccant-based dehumidifier systems that incorporate a thermally-regenerated desiccant material for dehumidification. This MOT is intended to function as the ''system'' testing and rating compliment to the desiccant ''component'' (desiccant wheels and/or cassettes) MOT (ASHRAE 1998) and rating standard (ARI 1998) already adopted by industry. This draft standard applies to ''packaged systems'' that: Use desiccants for dehumidification of conditioned air for buildings; Use heated air for regeneration of the desiccant material; Include fans for moving process and regeneration air; May include other system components for filtering, pre-cooling, post-cooling, or heating conditioned air; and May include other components for humidification of conditioned air. The proposed draft applies to four different system operating modes depending on whether outdoor or indoor air is used for process air and regeneration air streams . Only the ''ventilation'' mode which uses outdoor air for both process and regeneration inlets is evaluated in this paper. Performance of the dehumidification system is presented in terms that would be most familiar and useful to designers of building HVAC systems to facilitate integration of desiccant equipment with more conventional hardware. Parametric performance results from a modified, commercial desiccant dehumidifier undergoing laboratory testing were used as data input to evaluate the draft standard. Performance results calculated from this experimental input, results from an error-checking/heat-balance verification test built into the standard, and estimated comparisons between desiccant and similarly performing conventional dehumidification equipment are calculated and presented. Some variations in test procedures are suggested to aid in analytical assessment of individual component performance

  3. Standard Test Method for Solar Photometric Transmittance of Sheet Materials Using Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1996-01-01

    1.1 This test method covers the measurement of solar photometric transmittance of materials in sheet form. Solar photometric transmittance is measured using a photometer (illuminance meter) in an enclosure with the sun and sky as the source of radiation. The enclosure and method of test is specified in Test Method E 1175 (or Test Method E 1084). 1.2 The purpose of this test method is to specify a photometric sensor to be used with the procedure for measuring the solar photometric transmittance of sheet materials containing inhomogeneities in their optical properties. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  4. Usability Testing as a Method to Refine a Health Sciences Library Website.

    Science.gov (United States)

    Denton, Andrea H; Moody, David A; Bennett, Jason C

    2016-01-01

    User testing, a method of assessing website usability, can be a cost-effective and easily administered process to collect information about a website's effectiveness. A user experience (UX) team at an academic health sciences library has employed user testing for over three years to help refine the library's home page. Test methodology used in-person testers using the "think aloud" method to complete tasks on the home page. Review of test results revealed problem areas of the design and redesign; further testing was effective in refining the page. User testing has proved to be a valuable method to engage users and provide feedback to continually improve the library's home page.

  5. Studying the properties of Variational Data Assimilation Methods by Applying a Set of Test-Examples

    DEFF Research Database (Denmark)

    Thomsen, Per Grove; Zlatev, Zahari

    2007-01-01

    and backward computations are carried out by using the model under consideration and its adjoint equations (both the model and its adjoint are defined by systems of differential equations). The major difficulty is caused by the huge increase of the computational load (normally by a factor more than 100...... assimilation method (numerical algorithms for solving differential equations, splitting procedures and optimization algorithms) have been studied by using these tests. The presentation will include results from testing carried out in the study.......he variational data assimilation methods can successfully be used in different fields of science and engineering. An attempt to utilize available sets of observations in the efforts to improve (i) the models used to study different phenomena (ii) the model results is systematically carried out when...

  6. Further development of LLNA:DAE method as stand-alone skin-sensitization testing method and applied for evaluation of relative skin-sensitizing potency between chemicals.

    Science.gov (United States)

    Yamashita, Kunihiko; Shinoda, Shinsuke; Hagiwara, Saori; Itagaki, Hiroshi

    2015-04-01

    To date, there has been no well-established local lymph node assay (LLNA) that includes an elicitation phase. Therefore, we developed a modified local lymph node assay with an elicitation phase (LLNA:DAE) to discriminate true skin sensitizers from chemicals that gave borderline positive results and previously reported this assay. To develop the LLNA:DAE method as a useful stand-alone testing method, we investigated the complete procedure for the LLNA:DAE method using hexyl cinnamic aldehyde (HCA), isoeugenol, and 2,4-dinitrochlorobenzene (DNCB) as test compounds. We defined the LLNA:DAE procedure as follows: in the dose-finding test, four concentrations of chemical applied to dorsum of the right ear on days 1, 2, and 3 and dorsum of both ears on day 10. Ear thickness and skin irritation score were measured on days 1, 3, 5, 10, and 12. Local lymph nodes were excised and weighed on day 12. The test dose for the primary LLNA:DAE study was selected as the dose that gave the highest left ear lymph node weight in the dose-finding study, or the lowest dose that produced a left ear lymph node of over 4 mg. This procedure was validated using nine different chemicals. Furthermore, qualitative relationship was observed between the degree of elicitation response in the left ear lymph node and the skin sensitizing potency of 32 chemicals tested in this study and the previous study. These results indicated that LLNA:DAE method was as first LLNA method that was able to evaluate the skin sensitizing potential and potency in elicitation response.

  7. A comparison of sediment toxicity test methods at three Great Lake Areas of Concern

    Science.gov (United States)

    Burton, G. Allen; Ingersoll, Christopher G.; Burnett, LouAnn C.; Henry, Mary; Hinman, Mark L.; Klaine, Stephen J.; Landrum, Peter F.; Ross, Phillipe; Tuchman, Marc

    1996-01-01

    The significance of sediment contamination is often evaluated using sediment toxicity (bioassay) testing. There are relatively few “standardized” test methods for evaluating sediments. Popular sediment toxicity methods examine the extractable water (elutriate), interstitial water, or whole (bulk) sediment phases using test species spanning the aquatic food chain from bacteria to fish. The current study was designed to evaluate which toxicity tests were most useful in evaluations of sediment contamination at three Great Lake Areas of Concern. Responses of 24 different organisms including fish, mayflies, amphipods, midges, cladocerans, rotifers, macrophytes, algae, and bacteria were compared using whole sediment or elutriate toxicity assays. Sediments from several sites in the Buffalo River, Calumet River (Indiana Harbor), and Saginaw River were tested, as part of the U.S. Environmental Protection Agency's (USEPA) Assessment and Remediation of Contaminated Sediments (ARCS) Project. Results indicated several assays to be sensitive to sediment toxicity and able to discriminate between differing levels of toxicity. Many of the assay responses were significantly correlated to other toxicity responses and were similar based on factor analysis. For most applications, a test design consisting of two to three assays should adequately detect sediment toxicity, consisting of various groupings of the following species: Hyalella azteca, Ceriodaphnia dubia, Chironomus riparius, Chironomus tentans, Daphnia magna, Pimephales promelas, Hexagenia bilineata, Diporeia sp., Hydrilla verticillata, or Lemna minor.

  8. Study on the system-level test method of digital metering in smart substation

    Science.gov (United States)

    Zhang, Xiang; Yang, Min; Hu, Juan; Li, Fuchao; Luo, Ruixi; Li, Jinsong; Ai, Bing

    2017-03-01

    Nowadays, the test methods of digital metering system in smart substation are used to test and evaluate the performance of a single device, but these methods can only effectively guarantee the accuracy and reliability of the measurement results of a digital metering device in a single run, it does not completely reflect the performance when each device constitutes a complete system. This paper introduced the shortages of the existing test methods. A system-level test method of digital metering in smart substation was proposed, and the feasibility of the method was proved by the actual test.

  9. Testing of VVER reactor pressure vessels by TOFD method

    International Nuclear Information System (INIS)

    Skala, Z.; Vit, J.

    2002-01-01

    The Time of Flight Diffraction Method (TOFD) - one of the new testing methods capable to obtain the real dimensions of flaws - is presented in the paper.The laboratory experiments on samples with artificial flaws and samples with artificially prepared cracks confirmed the high accuracy of flaw through wall extent sizing by TOFD. This accuracy was confirmed by qualification of methods and systems used by Skoda JS for the in-service inspections of WWER 440 vessel circumferential weld. The qualification also confirmed the ability of TOFD to detect reliably flaws, which can are not reliably detected by standard pulse echo testing. Based on the result of experiments and qualification, the TOFD method shall be used routinely by Skoda JS for the inspection of vessel circumferential welds root area and for sizing of flaws exceeding the acceptance level

  10. Standard practice for measurement of the glass dissolution rate using the single-pass flow-through test method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice describes a single-pass flow-through (SPFT) test method that can be used to measure the dissolution rate of a homogeneous silicate glass, including nuclear waste glasses, in various test solutions at temperatures less than 100°C. Tests may be conducted under conditions in which the effects from dissolved species on the dissolution rate are minimized to measure the forward dissolution rate at specific values of temperature and pH, or to measure the dependence of the dissolution rate on the concentrations of various solute species. 1.2 Tests are conducted by pumping solutions in either a continuous or pulsed flow mode through a reaction cell that contains the test specimen. Tests must be conducted at several solution flow rates to evaluate the effect of the flow rate on the glass dissolution rate. 1.3 This practice excludes static test methods in which flow is simulated by manually removing solution from the reaction cell and replacing it with fresh solution. 1.4 Tests may be conducted wit...

  11. Improving Papanicolaou test quality and reducing medical errors by using Toyota production system methods.

    Science.gov (United States)

    Raab, Stephen S; Andrew-Jaja, Carey; Condel, Jennifer L; Dabbs, David J

    2006-01-01

    The objective of the study was to determine whether the Toyota production system process improves Papanicolaou test quality and patient safety. An 8-month nonconcurrent cohort study that included 464 case and 639 control women who had a Papanicolaou test was performed. Office workflow was redesigned using Toyota production system methods by introducing a 1-by-1 continuous flow process. We measured the frequency of Papanicolaou tests without a transformation zone component, follow-up and Bethesda System diagnostic frequency of atypical squamous cells of undetermined significance, and diagnostic error frequency. After the intervention, the percentage of Papanicolaou tests lacking a transformation zone component decreased from 9.9% to 4.7% (P = .001). The percentage of Papanicolaou tests with a diagnosis of atypical squamous cells of undetermined significance decreased from 7.8% to 3.9% (P = .007). The frequency of error per correlating cytologic-histologic specimen pair decreased from 9.52% to 7.84%. The introduction of the Toyota production system process resulted in improved Papanicolaou test quality.

  12. Phototoxicity: Its Mechanism and Animal Alternative Test Methods

    Science.gov (United States)

    Park, Hyeonji; Lim, Kyung-Min

    2015-01-01

    The skin exposure to solar irradiation and photoreactive xenobiotics may produce abnormal skin reaction, phototoxicity. Phototoxicity is an acute light-induced response, which occurs when photoreacive chemicals are activated by solar lights and transformed into products cytotoxic against the skin cells. Multifarious symptoms of phototoxicity are identified, skin irritation, erythema, pruritis, and edema that are similar to those of the exaggerated sunburn. Diverse organic chemicals, especially drugs, are known to induce phototoxicity, which is probably from the common possession of UV-absorbing benzene or heterocyclic rings in their molecular structures. Both UVB (290~320 nm) and UVA (320~400 nm) are responsible for the manifestation of phototoxicity. Absorption of photons and absorbed energy (hv) by photoactive chemicals results in molecular changes or generates reactive oxygen species and depending on the way how endogenous molecules are affected by phototoxicants, mechanisms of phototoxcity is categorized into two modes of action: Direct when unstable species from excited state directly react with the endogenous molecules, and indirect when endogeneous molecules react with secondary photoproducts. In order to identify phototoxic potential of a chemical, various test methods have been introduced. Focus is given to animal alternative test methods, i.e., in vitro, and in chemico assays as well as in vivo. 3T3 neutral red uptake assay, erythrocyte photohemolysis test, and phototoxicity test using human 3-dimensional (3D) epidermis model are examples of in vitro assays. In chemico methods evaluate the generation of reactive oxygen species or DNA strand break activity employing plasmid for chemicals, or drugs with phototoxic potential. PMID:26191378

  13. Comparison of shear-wave velocity measurements by crosshole, downhole and seismic cone penetration test methods

    Energy Technology Data Exchange (ETDEWEB)

    Suthaker, N.; Tweedie, R. [Thurber Engineering Ltd., Edmonton, AB (Canada)

    2009-07-01

    Shear wave velocity measurements are an integral part of geotechnical studies for major structures and are an important tool in their design for site specific conditions such as site-specific earthquake response. This paper reported on a study in which shear wave velocities were measured at a proposed petrochemical plant site near Edmonton, Alberta. The proposed site is underlain by lacustrine clay, glacial till and upper Cretaceous clay shale and sandstone bedrock. The most commonly used methods for determining shear wave velocity include crosshole seismic tests, downhole seismic tests, and seismic cone penetration tests (SCPT). This paper presented the results of all 3 methods used in this study and provided a comparison of the various test methods and their limitations. The crosshole test results demonstrated a common trend of increasing shear wave velocity with depth to about 15 m, below which the velocities remained relatively constant. An anomaly was noted at one site, where the shear wave velocity was reduced at a zone corresponding to clay till containing stiff high plastic clay layers. The field study demonstrated that reasonable agreement in shear wave velocity measurements can be made using crosshole, downhole and seismic tests in the same soil conditions. The National Building Code states that the shear wave velocity is the fundamental method for determining site classification, thus emphasizing the importance of obtaining shear wave velocity measurements for site classification. It was concluded that an SCPT program can be incorporated into the field program without much increase in cost and can be supplemented by downhole or crosshole techniques. 5 refs., 2 tabs., 10 figs.

  14. Nondestructive testing methods in building industry '83. Part 1

    International Nuclear Information System (INIS)

    1983-10-01

    The conference heard 52 papers of which 11 were incorporated in INIS. The subject of these was the use of radiometric methods and instruments for nondestructive testing of building materials and ways of testing the quality of concrete during nuclear power plant construction. (J.P.)

  15. Method for determining detailed rod worth profiles at low power in the fast test reactor

    International Nuclear Information System (INIS)

    Sevenich, R.A.

    1975-08-01

    A method for obtaining a detailed rod worth profile at low power for a slow control rod insertion is presented. The accuracy of the method depends on a preparatory experiment in which the test rod is dropped quickly to yield, upon analysis, the magnitude of the rod worth and an effective source value. These numbers are employed to initialize the inverse kinetics analysis for the slow insertion. Corrections for changes in detection efficiency are not included for the simulated experiments. (U.S.)

  16. Earthquake analysis of structures including structure-soil interaction by a substructure method

    International Nuclear Information System (INIS)

    Chopra, A.K.; Guttierrez, J.A.

    1977-01-01

    A general substructure method for analysis of response of nuclear power plant structures to earthquake ground motion, including the effects of structure-soil interaction, is summarized. The method is applicable to complex structures idealized as finite element systems and the soil region treated as either a continuum, for example as a viscoelastic halfspace, or idealized as a finite element system. The halfspace idealization permits reliable analysis for sites where essentially similar soils extend to large depths and there is no rigid boundary such as soil-rock interface. For sites where layers of soft soil are underlain by rock at shallow depth, finite element idealization of the soil region is appropriate; in this case, the direct and substructure methods would lead to equivalent results but the latter provides the better alternative. Treating the free field motion directly as the earthquake input in the substructure method eliminates the deconvolution calculations and the related assumption -regarding type and direction of earthquake waves- required in the direct method. The substructure method is computationally efficient because the two substructures-the structure and the soil region- are analyzed separately; and, more important, it permits taking advantage of the important feature that response to earthquake ground motion is essentially contained in the lower few natural modes of vibration of the structure on fixed base. For sites where essentially similar soils extend to large depths and there is no obvious rigid boundary such as a soil-rock interface, numerical results for earthquake response of a nuclear reactor structure are presented to demonstrate that the commonly used finite element method may lead to unacceptable errors; but the substructure method leads to reliable results

  17. Proposed waste form performance criteria and testing methods for low-level mixed waste

    International Nuclear Information System (INIS)

    Franz, E.M.; Fuhrmann, M.; Bowerman, B.; Bates, S.; Peters, R.

    1994-08-01

    This document describes proposed waste form performance criteria and testing method that could be used as guidance in judging viability of a waste form as a physico-chemical barrier to releases of radionuclides and RCRA regulated hazardous components. It is assumed that release of contaminants by leaching is the single most important property by which the effectiveness of a waste form is judged. A two-tier regimen is proposed. The first tier includes a leach test required by the Environmental Protection Agency and a leach test designed to determine the net forward leach rate for a variety of materials. The second tier of tests are to determine if a set of stresses (i.e., radiation, freeze-thaw, wet-dry cycling) on the waste form adversely impact its ability to retain contaminants and remain physically intact. It is recommended that the first tier tests be performed first to determine acceptability. Only on passing the given specifications for the leach tests should other tests be performed. In the absence of site-specific performance assessments (PA), two generic modeling exercises are described which were used to calculate proposed acceptable leach rates

  18. Stress corrosion evaluation of powder metallurgy aluminum alloy 7091 with the breaking load test method

    Science.gov (United States)

    Domack, Marcia S.

    1987-01-01

    The stress corrosion behavior of the P/M aluminum alloy 7091 is evaluated in two overaged heat treatment conditions, T7E69 and T7E70, using an accelerated test technique known as the breaking load test method. The breaking load data obtained in this study indicate that P/M 7091 alloy is highly resistant to stress corrosion in both longitudinal and transverse orientations at stress levels up to 90 percent of the material yield strength. The reduction in mean breaking stress as a result of corrosive attack is smallest for the more overaged T7E70 condition. Details of the test procedure are included.

  19. Standard test method for determining residual stresses by the hole-drilling strain-gage method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 Residual Stress Determination: 1.1.1 This test method specifies a hole-drilling procedure for determining residual stress profiles near the surface of an isotropic linearly elastic material. The test method is applicable to residual stress profile determinations where in-plane stress gradients are small. The stresses may remain approximately constant with depth (“uniform” stresses) or they may vary significantly with depth (“non-uniform” stresses). The measured workpiece may be “thin” with thickness much less than the diameter of the drilled hole or “thick” with thickness much greater than the diameter of the drilled hole. Only uniform stress measurements are specified for thin workpieces, while both uniform and non-uniform stress measurements are specified for thick workpieces. 1.2 Stress Measurement Range: 1.2.1 The hole-drilling method can identify in-plane residual stresses near the measured surface of the workpiece material. The method gives localized measurements that indicate the...

  20. Application of ISRM testing methods to fracture toughness testing of graphite

    International Nuclear Information System (INIS)

    Hashida, T.; Fukasawa, T.; Takahashi, H.; Ishiyama, S.; Oku, T.

    1987-01-01

    Fracture toughness measurements of nuclear grade graphites, IG11 and PGX, were made by means of AE technique. Tests were conducted on edge-notched round bend bar, edge-notched short bar and round compact tension specimens. These round-shaped specimens used in this study have been proposed for standard fracture toughness tests of rock as a draft of testing standard of International Society for Rock Mechanics (ISRM). Taking the observed nonlinear deformation behavior into account, J-integral approach was utilized to determine the fracture toughness of the graphites. It is shown that the critical J integral determined by AE technique, J iAE , is independent of specimen geometry. Based on this experimental results, the fracture toughness K IC of the graphites was determined from the J iAE values. K IC value of IG11 was 1.04 MPa√m, and 0.77 MPa√m for PGX respectively. Furthermore, the specimen size effect of the fracture toughness determined by the J-integral/AE method is discussed. (author)

  1. Masonry fireplace emissions test method: Repeatability and sensitivity to fueling protocol.

    Science.gov (United States)

    Stern, C H; Jaasma, D R; Champion, M R

    1993-03-01

    A test method for masonry fireplaces has been evaluated during testing on six masonry fireplace configurations. The method determines carbon monoxide and particulate matter emission rates (g/h) and factors (g/kg) and does not require weighing of the appliance to determine the timing of fuel loading.The intralaboratory repeatability of the test method has been determined from multiple tests on the six fireplaces. For the tested fireplaces, the ratio of the highest to lowest measured PM rate averaged 1.17 and in no case was greater than 1.32. The data suggest that some of the variation is due to differences in fuel properties.The influence of fueling protocol on emissions has also been studied. A modified fueling protocol, tested in large and small fireplaces, reduced CO and PM emission factors by roughly 40% and reduced CO and PM rates from 0 to 30%. For both of these fireplaces, emission rates were less sensitive to fueling protocol than emission factors.

  2. New engine method for biodiesel cetane number testing

    Directory of Open Access Journals (Sweden)

    Pešić Radivoje B.

    2008-01-01

    Full Text Available Substitution of fossil fuels with fuels that come from part renewable sources has been a subject of many studies and researches in the past decade. Considering the higher cost and limits of production resources, a special attention is focused on raising the energy efficiency of biofuel usage, mainly through optimization of the combustion process. Consequently, in biofuel applications, there is a need for determination of auto-ignition quality expressed by cetane number as a dominant characteristic that influences combustion parameters. The fact that the method for cetane number determination is comparative in nature has led us to try to develop substitute engine method for cetane number determination, by the use of the available laboratory equipment and serial, mono-cylinder engine with direct injection, DMB LDA 450. Description of the method, results of optimization of engine’s working parameters for conduction of the test and method’s Accuracy estimation are given in the paper. The paper also presents the results of domestic biodiesel fuels cetane number testing with the application of described engine method, developed at the Laboratory for internal combustion engines and fuels and lubricants of the Faculty of Mechanical Engineering from Kragujevac, Serbia.

  3. Testing methods of steel wi re ropes at the anchor

    Directory of Open Access Journals (Sweden)

    Stanislav Kropuch

    2012-12-01

    Full Text Available The present paper introduces an application of the acoustic andthermographic method in the defectoscopic testing of immobilesteel wire ropes at the most critical point, the anchor. Firstmeasurements and their results by these new defectoscopic methodsare shown. In defectoscopic tests at the anchor, the widelyused magnetic method gives unreliable results, and therefore presentsa problem for steel wire defectoscopy. Application of the two new methods in the steel wire defectoscopy at the anchor point will enableincreased safety measures at the anchor of steel wire ropes in bridge, roof, tower and aerial cable lift constructions.

  4. Effects of test method and participant musical training on preference ratings of stimuli with different reverberation times.

    Science.gov (United States)

    Lawless, Martin S; Vigeant, Michelle C

    2017-10-01

    Selecting an appropriate listening test design for concert hall research depends on several factors, including listening test method and participant critical-listening experience. Although expert listeners afford more reliable data, their perceptions may not be broadly representative. The present paper contains two studies that examined the validity and reliability of the data obtained from two listening test methods, a successive and a comparative method, and two types of participants, musicians and non-musicians. Participants rated their overall preference of auralizations generated from eight concert hall conditions with a range of reverberation times (0.0-7.2 s). Study 1, with 34 participants, assessed the two methods. The comparative method yielded similar results and reliability as the successive method. Additionally, the comparative method was rated as less difficult and more preferable. For study 2, an additional 37 participants rated the stimuli using the comparative method only. An analysis of variance of the responses from both studies revealed that musicians are better than non-musicians at discerning their preferences across stimuli. This result was confirmed with a k-means clustering analysis on the entire dataset that revealed five preference groups. Four groups exhibited clear preferences to the stimuli, while the fifth group, predominantly comprising non-musicians, demonstrated no clear preference.

  5. The former Semipalatinsk Test Site survey by field γ-spectrometry method

    International Nuclear Information System (INIS)

    Pakhomov, S.A.; Dubasov, Yu.V.; Biryukov, E.I.; Gavrilin, S.S.; Ilyin, L.I.

    2001-01-01

    Full text: Field γ-spectrometry method is the most productive method of getting an information on gamma-irradiating radionuclides contents in objects under survey. For many years the Radium Institute was the most active participant of works on radiation survey of the Semipalatinsk Test Site, field γ-spectrometry method including. In field γ-spectrometry method realization the existence of corresponding apparatus, and methodic software is supposed to be allowing to carry out both measurement, recording of γ-spectrometry energetic characteristics in field conditions and final treatment (using corresponding physical models) ensuring obtaining the information on radionuclides' contents. Different variants of such apparatus were developed and made at the Radium Institute. Under conditions of complex spectral structure and high intensity existence a portable variant of Ge(Li)-detector spectrometer fed by alkaline accumulators and allowing to record a spectrum at high load was elaborated. For walk γ-survey in common with the University two variants of portable spectrometers 'Skif-3' were elaborated: one of them with a standard scintillation detector on the base of Nal(Ti) crystal, having the size of 63x63 mm, and the other is an 'X-ray' detector of large dimension on the base of CsI crystal with a diameter of 165 mm, designated for soft gamma-irradiation registration, 241 Am including. During 8 hours of independent works 'Skif-3' is able to record into internal memory up to 100 spectra with an exposure up to 9999 s. At 10 min exposure in its sensitivity of 241 Am finding (10 Bq/kg) a spectrometer 'Skif-3' excels a portable spectrometer 'InSpector' (Canberra) working with the exposure of 1 hour. For automobile measurements a car spectrometer was elaborated fed. from car board supply and having four detectors based on NaI crystals with the dimensions 200x110 mm and total volume of about 121. For express treatment of a 'Skif-3' spectrometer scintillation spectra special

  6. Standard Test Method for Hydrophobic Surface Films by the Water-Break Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the detection of the presence of hydrophobic (nonwetting) films on surfaces and the presence of hydrophobic organic materials in processing ambients. When properly conducted, the test will enable detection of molecular layers of hydrophobic organic contaminants. On very rough or porous surfaces, the sensitivity of the test may be significantly decreased. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  7. Standard test method for measurement of soil resistivity using the two-electrode soil box method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the equipment and a procedure for the measurement of soil resistivity, for samples removed from the ground, for use in the control of corrosion of buried structures. 1.2 Procedures allow for this test method to be used n the field or in the laboratory. 1.3 The test method procedures are for the resistivity measurement of soil samples in the saturated condition and in the as-received condition. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. Soil resistivity values are reported in ohm-centimeter. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

  8. STANDARD METHODS FOR THE DETERMINATION OF THE RUNWAY AND SEAKEEPING CHARACTERISTICS OF A SEAPLANE ON THE WATERS DURING FULL-SCALE TESTS

    Directory of Open Access Journals (Sweden)

    A. A. Khokhlov

    2015-01-01

    Full Text Available One of the main stages of the creation of seaplanes and amphibious aircraft are flight certification tests, including tests to determine their landing and sailing characteristics on the water. In accordance with aviation regulations (part 21 certification work is carried out according to the methods of determination of compliance (MOC, which are the main organizational and methodological document for testing. The paper discusses the main provisions of the standard methods for the determination of the runway and sea keeping characteristics of seaplanes and amphibians on water areas with full-scale tests.

  9. Adverse reactions to cosmetics and methods of testing.

    Science.gov (United States)

    Nigam, P K

    2009-01-01

    Untoward reactions to cosmetics, toiletries, and topical applications are the commonest single reason for hospital referrals with allergic contact dermatitis. In most cases, these are only mild or transient and most reactions being irritant rather than allergic in nature. Various adverse effects may occur in the form of acute toxicity, percutaneous absorption, skin irritation, eye irritation, skin sensitization and photosensitization, subchronic toxicity, mutagenicity/genotoxicity, and phototoxicity/photoirritation. The safety assessment of a cosmetic product clearly depends upon how it is used, since it determines the amount of substance which may be ingested, inhaled, or absorbed through the skin or mucous membranes. Concentration of ingredients used in the different products is also important. Various test procedures include in vivo animal models and in vitro models, such as open or closed patch test, in vivo skin irritation test, skin corrosivity potential tests (rat skin transcutaneous electrical resistance test, Episkin test), eye irritation tests (in vivo eye irritancy test and Draize eye irritancy test), mutagenicity/genotoxicity tests (in vitro bacterial reverse mutation test and in vitro mammalian cell chromosome aberration test), and phototoxicity/photoirritation test (3T3 neutral red uptake phototoxicity test). Finished cosmetic products are usually tested in small populations to confirm the skin and mucous membrane compatibility, and to assess their cosmetic acceptability.

  10. Comparison of different methods to include recycling in LCAs of aluminium cans and disposable polystyrene cups

    NARCIS (Netherlands)

    Harst-Wintraecken, van der Eugenie; Potting, José; Kroeze, Carolien

    2016-01-01

    Many methods have been reported and used to include recycling in life cycle assessments (LCAs). This paper evaluates six widely used methods: three substitution methods (i.e. substitution based on equal quality, a correction factor, and alternative material), allocation based on the number of

  11. Standard test method for measuring waste glass or glass ceramic durability by vapor hydration test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 The vapor hydration test method can be used to study the corrosion of a waste forms such as glasses and glass ceramics upon exposure to water vapor at elevated temperatures. In addition, the alteration phases that form can be used as indicators of those phases that may form under repository conditions. These tests; which allow altering of glass at high surface area to solution volume ratio; provide useful information regarding the alteration phases that are formed, the disposition of radioactive and hazardous components, and the alteration kinetics under the specific test conditions. This information may be used in performance assessment (McGrail et al, 2002 (1) for example). 1.2 This test method must be performed in accordance with all quality assurance requirements for acceptance of the data. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practice...

  12. Evaluation of the Thermo Scientific SureTect Listeria species assay. AOAC Performance Tested Method 071304.

    Science.gov (United States)

    Cloke, Jonathan; Evans, Katharine; Crabtree, David; Hughes, Annette; Simpson, Helen; Holopainen, Jani; Wickstrand, Nina; Kauppinen, Mikko; Leon-Velarde, Carlos; Larson, Nathan; Dave, Keron

    2014-01-01

    The Thermo Scientific SureTect Listeria species Assay is a new real-time PCR assay for the detection of all species of Listeria in food and environmental samples. This validation study was conducted using the AOAC Research Institute (RI) Performance Tested Methods program to validate the SureTect Listeria species Assay in comparison to the reference method detailed in International Organization for Standardization 11290-1:1996 including amendment 1:2004 in a variety of foods plus plastic and stainless steel. The food matrixes validated were smoked salmon, processed cheese, fresh bagged spinach, cantaloupe, cooked prawns, cooked sliced turkey meat, cooked sliced ham, salami, pork frankfurters, and raw ground beef. All matrixes were tested by Thermo Fisher Scientific, Microbiology Division, Basingstoke, UK. In addition, three matrixes (pork frankfurters, fresh bagged spinach, and stainless steel surface samples) were analyzed independently as part of the AOAC-RI-controlled independent laboratory study by the University ofGuelph, Canada. Using probability of detection statistical analysis, a significant difference in favour of the SureTect assay was demonstrated between the SureTect and reference method for high level spiked samples of pork frankfurters, smoked salmon, cooked prawns, stainless steel, and low-spiked samples of salami. For all other matrixes, no significant difference was seen between the two methods during the study. Inclusivity testing was conducted with 68 different isolates of Listeria species, all of which were detected by the SureTect Listeria species Assay. None of the 33 exclusivity isolates were detected by the SureTect Listeria species Assay. Ruggedness testing was conducted to evaluate the performance of the assay with specific method deviations outside of the recommended parameters open to variation, which demonstrated that the assay gave reliable performance. Accelerated stability testing was additionally conducted, validating the assay

  13. Testing a Preliminary Live with Love Conceptual Framework for cancer couple dyads: A mixed-methods study.

    Science.gov (United States)

    Li, Qiuping; Xu, Yinghua; Zhou, Huiya; Loke, Alice Yuen

    2015-12-01

    The purpose of this study was to test the previous proposed Preliminary Live with Love Conceptual Framework (P-LLCF) that focuses on spousal caregiver-patient couples in their journey of coping with cancer as dyads. A mixed-methods study that included qualitative and quantitative approaches was conducted. Methods of concept and theory analysis, and structural equation modeling (SEM) were applied in testing the P-LLCF. In the qualitative approach in testing the concepts included in the P-LLCF, a comparison was made between the P-LLCF with a preliminary conceptual framework derived from focus group interviews among Chinese couples' coping with cancer. The comparison showed that the concepts identified in the P-LLCF are relevant to the phenomenon under scrutiny, and attributes of the concepts are consistent with those identified among Chinese cancer couple dyads. In the quantitative study, 117 cancer couples were recruited. The findings showed that inter-relationships exist among the components included in the P-LLCF: event situation, dyadic mediators, dyadic appraisal, dyadic coping, and dyadic outcomes. In that the event situation will impact the dyadic outcomes directly or indirectly through Dyadic Mediators. The dyadic mediators, dyadic appraisal, and dyadic coping are interrelated and work together to benefit the dyadic outcomes. This study provides evidence that supports the interlinked components and the relationship included in the P-LLCF. The findings of this study are important in that they provide healthcare professionals with guidance and directions according to the P-LLCF on how to plan supportive programs for couples coping with cancer. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. An accelerated test method of luminous flux depreciation for LED luminaires and lamps

    International Nuclear Information System (INIS)

    Qian, C.; Fan, X.J.; Fan, J.J.; Yuan, C.A.; Zhang, G.Q.

    2016-01-01

    Light Emitting Diode (LED) luminaires and lamps are energy-saving and environmental friendly alternatives to traditional lighting products. However, current luminous flux depreciation test at luminaire and lamp level requires a minimum of 6000 h testing, which is even longer than the product development cycle time. This paper develops an accelerated test method for luminous flux depreciation to reduce the test time within 2000 h at an elevated temperature. The method is based on lumen maintenance boundary curve, obtained from a collection of LED source lumen depreciation data, known as LM-80 data. The exponential decay model and Arrhenius acceleration relationship are used to determine the new threshold of lumen maintenance and acceleration factor. The proposed method has been verified by a number of simulation studies and experimental data for a wide range of LED luminaire and lamp types from both internal and external experiments. The qualification results obtained by the accelerated test method agree well with traditional 6000 h tests. - Highlights: • We develop an accelerated test method for LED luminaires and lamps. • The method is proposed based on a “Boundary Curve” concept. • The parameters of the boundary curve are extracted from LM-80 test reports. • Qualification results from the proposed method agree with ES requirements.

  15. Contrast sensitivity measured by two different test methods in healthy, young adults with normal visual acuity.

    Science.gov (United States)

    Koefoed, Vilhelm F; Baste, Valborg; Roumes, Corinne; Høvding, Gunnar

    2015-03-01

    This study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy, young adults with normal uncorrected visual acuity. Based on these results, the index of contrast sensitivity (ICS) is calculated, aiming to establish ICS reference values for this population and to evaluate the possible usefulness of ICS as a tool to compare the degree of agreement between different CS test methods. Military recruits with best eye uncorrected visual acuity 0.00 LogMAR or better, normal colour vision and age 18-25 years were included in a study to record contrast sensitivity using Optec 6500 (FACT) at spatial frequencies of 1.5, 3, 6, 12 and 18 cpd in photopic and mesopic light and CSV-1000E at spatial frequencies of 3, 6, 12 and 18 cpd in photopic light. Index of contrast sensitivity was calculated based on data from the three tests, and the Bland-Altman technique was used to analyse the agreement between ICS obtained by the different test methods. A total of 180 recruits were included. Contrast sensitivity frequency data for all tests were highly skewed with a marked ceiling effect for the photopic tests. The median ICS for Optec 6500 at 85 cd/m2 was -0.15 (95% percentile 0.45), compared with -0.00 (95% percentile 1.62) for Optec at 3 cd/m2 and 0.30 (95% percentile 1.20) FOR CSV-1000E. The mean difference between ICSFACT 85 and ICSCSV was -0.43 (95% CI -0.56 to -0.30, p<0.00) with limits of agreement (LoA) within -2.10 and 1.22. The regression line on the difference of average was near to zero (R2=0.03). The results provide reference CS and ICS values in a young, adult population with normal visual acuity. The agreement between the photopic tests indicated that they may be used interchangeably. There was little agreement between the mesopic and photopic tests. The mesopic test seemed best suited to differentiate between candidates and may therefore possibly be useful for medical selection purposes.

  16. Standard test method for measurement of fatigue crack growth rates

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2015-01-01

    1.1 This test method covers the determination of fatigue crack growth rates from near-threshold to Kmax controlled instability. Results are expressed in terms of the crack-tip stress-intensity factor range (ΔK), defined by the theory of linear elasticity. 1.2 Several different test procedures are provided, the optimum test procedure being primarily dependent on the magnitude of the fatigue crack growth rate to be measured. 1.3 Materials that can be tested by this test method are not limited by thickness or by strength so long as specimens are of sufficient thickness to preclude buckling and of sufficient planar size to remain predominantly elastic during testing. 1.4 A range of specimen sizes with proportional planar dimensions is provided, but size is variable to be adjusted for yield strength and applied force. Specimen thickness may be varied independent of planar size. 1.5 The details of the various specimens and test configurations are shown in Annex A1-Annex A3. Specimen configurations other than t...

  17. Test Method for High β Particle Emission Rate of 63Ni Source Plate

    OpenAIRE

    ZHANG Li-feng

    2015-01-01

    For the problem of measurement difficulties of β particle emission rate of Ni-63 source plate used for Ni-63 betavoltaic battery, a relative test method of scintillation current method was erected according to the measurement principle of scintillation detector.β particle emission rate of homemade Ni-63 source plate was tested by the method, and the test results were analysed and evaluated, it was initially thought that scintillation current method was a feasible way of testing β particle emi...

  18. Interesting Developments in Testing Methods Applied to Foundation Piles

    Science.gov (United States)

    Sobala, Dariusz; Tkaczyński, Grzegorz

    2017-10-01

    Both: piling technologies and pile testing methods are a subject of current development. New technologies, providing larger diameters or using in-situ materials, are very demanding in terms of providing proper quality of execution of works. That concerns the material quality and continuity which define the integral strength of pile. On the other side we have the capacity of the ground around the pile and its ability to carry the loads transferred by shaft and pile base. Inhomogeneous nature of soils and a relatively small amount of tested piles imposes very good understanding of small amount of results. In some special cases the capacity test itself form an important cost in the piling contract. This work presents a brief description of selected testing methods and authors remarks based on cooperation with Universities constantly developing new ideas. Paper presents some experience based remarks on integrity testing by means of low energy impact (low strain) and introduces selected (Polish) developments in the field of closed-end pipe piles testing based on bi-directional loading, similar to Osterberg idea, but without sacrificial hydraulic jack. Such test is suitable especially when steel piles are used for temporary support in the rivers, where constructing of conventional testing appliance with anchor piles or kentledge meets technical problems. According to the author’s experience, such tests were not yet used on the building site but they bring a real potential especially, when the displacement control can be provided from the river bank using surveying techniques.

  19. Standard Test Method for Testing Polymeric Seal Materials for Geothermal and/or High Temperature Service Under Sealing Stress

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This test method covers the initial evaluation of (screening) polymeric materials for seals under static sealing stress and at elevated temperatures. 1.2 This test method applies to geothermal service only if used in conjunction with Test Method E 1068. 1.3 The test fluid is distilled water. 1.4 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  20. Development of test bolus tracking method and usefulness in coronary CT angiography

    International Nuclear Information System (INIS)

    Yamaguchi, Takayoshi; Takahashi, Daichi

    2009-01-01

    The test bolus tracking (TBT) method is a new injection method of contrast medium that we developed. The TBT method is an injection technique that continuously performs the test bolus injection and the main bolus injection, such that the best acquisition of scan timing and the improvement of examination efficiency can be expected. We compared the TBT method and the test injection method by coronary CT angiography. The results demonstrated that the contrast enhancement of the coronary arteries was high and the variation of the CT value was also small in the TBT method. When the scan timing expected by the TI method and the TBT method were compared, it was different of two seconds or more by the case with 43%. However, the variation of CT value was small for the TBT method in these cases. Therefore, the TBT method is a very useful method for coronary CT angiography (CCTA). (author)

  1. Resampling-based methods in single and multiple testing for equality of covariance/correlation matrices.

    Science.gov (United States)

    Yang, Yang; DeGruttola, Victor

    2012-06-22

    Traditional resampling-based tests for homogeneity in covariance matrices across multiple groups resample residuals, that is, data centered by group means. These residuals do not share the same second moments when the null hypothesis is false, which makes them difficult to use in the setting of multiple testing. An alternative approach is to resample standardized residuals, data centered by group sample means and standardized by group sample covariance matrices. This approach, however, has been observed to inflate type I error when sample size is small or data are generated from heavy-tailed distributions. We propose to improve this approach by using robust estimation for the first and second moments. We discuss two statistics: the Bartlett statistic and a statistic based on eigen-decomposition of sample covariance matrices. Both statistics can be expressed in terms of standardized errors under the null hypothesis. These methods are extended to test homogeneity in correlation matrices. Using simulation studies, we demonstrate that the robust resampling approach provides comparable or superior performance, relative to traditional approaches, for single testing and reasonable performance for multiple testing. The proposed methods are applied to data collected in an HIV vaccine trial to investigate possible determinants, including vaccine status, vaccine-induced immune response level and viral genotype, of unusual correlation pattern between HIV viral load and CD4 count in newly infected patients.

  2. A new Laplace transformation method for dynamic testing of solar collectors

    DEFF Research Database (Denmark)

    Kong, Weiqiang; Perers, Bengt; Fan, Jianhua

    2015-01-01

    A new dynamic method for solar collector testing is developed. It is characterized by using the Laplace transformation technique to solve the differential governing equation. The new method was inspired by the so called New Dynamic Method (NDM) (Amer E. et al (1999) [1]) but totally different....... By integration of the Laplace transformation technique with the Quasi Dynamic Test (QDT) model (Fischer S. et al (2004) [2]), the Laplace – QDT (L-QDT) model is derived. Two experimental methods are then introduced. One is the shielding method which needs to shield and un-shield solar collector continuously...

  3. Single well surfactant test to evaluate surfactant floods using multi tracer method

    Science.gov (United States)

    Sheely, Clyde Q.

    1979-01-01

    Data useful for evaluating the effectiveness of or designing an enhanced recovery process said process involving mobilizing and moving hydrocarbons through a hydrocarbon bearing subterranean formation from an injection well to a production well by injecting a mobilizing fluid into the injection well, comprising (a) determining hydrocarbon saturation in a volume in the formation near a well bore penetrating formation, (b) injecting sufficient mobilizing fluid to mobilize and move hydrocarbons from a volume in the formation near the well bore, and (c) determining the hydrocarbon saturation in a volume including at least a part of the volume of (b) by an improved single well surfactant method comprising injecting 2 or more slugs of water containing the primary tracer separated by water slugs containing no primary tracer. Alternatively, the plurality of ester tracers can be injected in a single slug said tracers penetrating varying distances into the formation wherein the esters have different partition coefficients and essentially equal reaction times. The single well tracer method employed is disclosed in U.S. Pat. No. 3,623,842. This method designated the single well surfactant test (SWST) is useful for evaluating the effect of surfactant floods, polymer floods, carbon dioxide floods, micellar floods, caustic floods and the like in subterranean formations in much less time and at much reduced cost compared to conventional multiwell pilot tests.

  4. Application of Bayesian Methods for Detecting Fraudulent Behavior on Tests

    Science.gov (United States)

    Sinharay, Sandip

    2018-01-01

    Producers and consumers of test scores are increasingly concerned about fraudulent behavior before and during the test. There exist several statistical or psychometric methods for detecting fraudulent behavior on tests. This paper provides a review of the Bayesian approaches among them. Four hitherto-unpublished real data examples are provided to…

  5. Methods study of homogeneity and stability test from cerium oxide CRM candidate

    International Nuclear Information System (INIS)

    Samin; Susanna TS

    2016-01-01

    The methods study of homogeneity and stability test from cerium oxide CRM candidate has been studied based on ISO 13258 and KAN DP. 01. 34. The purpose of this study was to select the test method homogeneity and stability tough on making CRM cerium oxide. Prepared 10 sub samples of cerium oxide randomly selected types of analytes which represent two compounds, namely CeO_2 and La_2O_3. At 10 sub sample is analyzed CeO_2 and La_2O_3 contents in duplicate with the same analytical methods, by the same analyst, and in the same laboratory. Data analysis results calculated statistically based on ISO 13528 and KAN DP.01.34. According to ISO 13528 Cerium Oxide samples said to be homogeneous if Ss ≤ 0.3 σ and is stable if | Xr – Yr | ≤ 0.3 σ. In this study, the data of homogeneity test obtained CeO_2 is Ss = 2.073 x 10-4 smaller than 0.3 σ (0.5476) and the stability test obtained | Xr - Yr | = 0.225 and the price is < 0.3 σ. Whereas for La_2O_3, the price for homogeneity test obtained Ss = 1.649 x 10-4 smaller than 0.3 σ (0.4865) and test the stability of the price obtained | Xr - Yr | = 0.2185 where the price is < 0.3 σ. Compared with the method from KAN, a sample of cerium oxide has also been homogenized for Fcalc < Ftable and stable, because | Xi - Xhm | < 0.3 x n IQR. Provided that the results of the evaluation homogeneity and stability test from CeO_2 CRM candidate test data were processed using statistical methods ISO 13528 is not significantly different with statistical methods from KAN DP.01.34, which together meet the requirements of a homogeneous and stable. So the test method homogeneity and stability test based on ISO 13528 can be used to make CRM cerium oxide. (author)

  6. Self-test Monte Carlo method

    International Nuclear Information System (INIS)

    Ohta, Shigemi

    1996-01-01

    The Self-Test Monte Carlo (STMC) method resolves the main problems in using algebraic pseudo-random numbers for Monte Carlo (MC) calculations: that they can interfere with MC algorithms and lead to erroneous results, and that such an error often cannot be detected without known exact solution. STMC is based on good randomness of about 10 10 bits available from physical noise or transcendental numbers like π = 3.14---. Various bit modifiers are available to get more bits for applications that demands more than 10 10 random bits such as lattice quantum chromodynamics (QCD). These modifiers are designed so that a) each of them gives a bit sequence comparable in randomness as the original if used separately from each other, and b) their mutual interference when used jointly in a single MC calculation is adjustable. Intermediate data of the MC calculation itself are used to quantitatively test and adjust the mutual interference of the modifiers in respect of the MC algorithm. STMC is free of systematic error and gives reliable statistical error. Also it can be easily implemented on vector and parallel supercomputers. (author)

  7. Multifrequency Excitation Method for Rapid and Accurate Dynamic Test of Micromachined Gyroscope Chips

    Directory of Open Access Journals (Sweden)

    Yan Deng

    2014-10-01

    Full Text Available A novel multifrequency excitation (MFE method is proposed to realize rapid and accurate dynamic testing of micromachined gyroscope chips. Compared with the traditional sweep-frequency excitation (SFE method, the computational time for testing one chip under four modes at a 1-Hz frequency resolution and 600-Hz bandwidth was dramatically reduced from 10 min to 6 s. A multifrequency signal with an equal amplitude and initial linear-phase-difference distribution was generated to ensure test repeatability and accuracy. The current test system based on LabVIEW using the SFE method was modified to use the MFE method without any hardware changes. The experimental results verified that the MFE method can be an ideal solution for large-scale dynamic testing of gyroscope chips and gyroscopes.

  8. Testing methods of ECR ion source experimental platform

    International Nuclear Information System (INIS)

    Zhou Changgeng; Hu Yonghong; Li Yan

    2006-12-01

    The principle and structure of ECR ion source experimental platform were introduce. The testing methods of the parameters of single main component and the comprehensive parameters under the condition of certain beam current and beam spot diameter were summarized in process of manufacturing. Some appropriate testing dates were given. The existent questions (the parameters of plasma density in discharge chamber and accurate hydrogen flow, etc. can not be measured in operation) and resolutions were also put forward. (authors)

  9. Effect of testing methods on the bond strength of resin to zirconia-alumina ceramic : microtensile versus shear test

    NARCIS (Netherlands)

    Valandro, Luiz F.; Ozcan, Mutlu; Amaral, Regina; Vanderlei, Aleska; Bottino, Marco A.

    2008-01-01

    This study tested the bond strength of a resin cement to a glass-infiltrated zirconia-alumina ceramic after three conditioning methods and using two test methods (shear-SBS versus microtensile-MTBS). Ceramic blocks for MTBS and ceramic disks for SBS were fabricated. Three surface conditioning (SC)

  10. Quantitative Evaluation of gamma-Spectrum Analysis Methods using IAEA Test Spectra

    DEFF Research Database (Denmark)

    Nielsen, Sven Poul

    1982-01-01

    A description is given of a γ-spectrum analysis method based on nonlinear least-squares fitting. The quality of the method is investigated by using statistical tests on the results from analyses of IAEA test spectra. By applying an empirical correction factor of 0.75 to the calculated peak-area u...

  11. Adverse reactions to cosmetics and methods of testing

    Directory of Open Access Journals (Sweden)

    Nigam P

    2009-01-01

    Full Text Available Untoward reactions to cosmetics, toiletries, and topical applications are the commonest single reason for hospital referrals with allergic contact dermatitis. In most cases, these are only mild or transient and most reactions being irritant rather than allergic in nature. Various adverse effects may occur in the form of acute toxicity, percutaneous absorption, skin irritation, eye irritation, skin sensitization and photosensitization, subchronic toxicity, mutagenicity/genotoxicity, and phototoxicity/photoirritation. The safety assessment of a cosmetic product clearly depends upon how it is used, since it determines the amount of substance which may be ingested, inhaled, or absorbed through the skin or mucous membranes. Concentration of ingredients used in the different products is also important. Various test procedures include in vivo animal models and in vitro models, such as open or closed patch test, in vivo skin irritation test, skin corrosivity potential tests (rat skin transcutaneous electrical resistance test, Episkin test, eye irritation tests (in vivo eye irritancy test and Draize eye irritancy test, mutagenicity/genotoxicity tests (in vitro bacterial reverse mutation test and in vitro mammalian cell chromosome aberration test, and phototoxicity/photoirritation test (3T3 neutral red uptake phototoxicity test. Finished cosmetic products are usually tested in small populations to confirm the skin and mucous membrane compatibility, and to assess their cosmetic acceptability.

  12. Post-Decontamination Vapor Sampling and Analytical Test Methods

    Science.gov (United States)

    2015-08-12

    is decontaminated that could pose an exposure hazard to unprotected personnel. The chemical contaminants may include chemical warfare agents (CWAs... decontamination process. Chemical contaminants can include chemical warfare agents (CWAs) or their simulants, nontraditional agents (NTAs), toxic industrial...a range of test articles from coupons, panels, and small fielded equipment items. 15. SUBJECT TERMS Vapor hazard; vapor sampling; chemical warfare

  13. Mirror bootstrap method for testing hypotheses of one mean

    OpenAIRE

    Varvak, Anna

    2012-01-01

    The general philosophy for bootstrap or permutation methods for testing hypotheses is to simulate the variation of the test statistic by generating the sampling distribution which assumes both that the null hypothesis is true, and that the data in the sample is somehow representative of the population. This philosophy is inapplicable for testing hypotheses for a single parameter like the population mean, since the two assumptions are contradictory (e.g., how can we assume both that the mean o...

  14. Assessment of Advanced Life Support competence when combining different test methods--reliability and validity

    DEFF Research Database (Denmark)

    Ringsted, C; Lippert, F; Hesselfeldt, R

    2007-01-01

    Cardiac Arrest Simulation Test (CASTest) scenarios for the assessments according to guidelines 2005. AIMS: To analyse the reliability and validity of the individual sub-tests provided by ERC and to find a combination of MCQ and CASTest that provides a reliable and valid single effect measure of ALS...... that possessed high reliability, equality of test sets, and ability to discriminate between the two groups of supposedly different ALS competence. CONCLUSIONS: ERC sub-tests of ALS competence possess sufficient reliability and validity. A combined ALS score with equal weighting of one MCQ and one CASTest can...... competence. METHODS: Two groups of participants were included in this randomised, controlled experimental study: a group of newly graduated doctors, who had not taken the ALS course (N=17) and a group of students, who had passed the ALS course 9 months before the study (N=16). Reliability in terms of inter...

  15. Standard test method for nondestructive assay of special nuclear material in low density scrap and waste by segmented passive gamma-Ray scanning

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the transmission-corrected nondestructive assay (NDA) of gamma-ray emitting special nuclear materials (SNMs), most commonly 235U, 239Pu, and 241Am, in low-density scrap or waste, packaged in cylindrical containers. The method can also be applied to NDA of other gamma-emitting nuclides including fission products. High-resolution gamma-ray spectroscopy is used to detect and measure the nuclides of interest and to measure and correct for gamma-ray attenuation in a series of horizontal segments (collimated gamma detector views) of the container. Corrections are also made for counting losses occasioned by signal processing limitations (1-3). 1.2 There are currently several systems in use or under development for determining the attenuation corrections for NDA of radioisotopic materials (4-8). A related technique, tomographic gamma-ray scanning (TGS), is not included in this test method (9, 10, 11). 1.2.1 This test method will cover two implementations of the Segmented Gamma Scanning ...

  16. Standard test methods for determining chemical durability of nuclear, hazardous, and mixed waste glasses and multiphase glass ceramics: The product consistency test (PCT)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 These product consistency test methods A and B evaluate the chemical durability of homogeneous glasses, phase separated glasses, devitrified glasses, glass ceramics, and/or multiphase glass ceramic waste forms hereafter collectively referred to as “glass waste forms” by measuring the concentrations of the chemical species released to a test solution. 1.1.1 Test Method A is a seven-day chemical durability test performed at 90 ± 2°C in a leachant of ASTM-Type I water. The test method is static and conducted in stainless steel vessels. Test Method A can specifically be used to evaluate whether the chemical durability and elemental release characteristics of nuclear, hazardous, and mixed glass waste forms have been consistently controlled during production. This test method is applicable to radioactive and simulated glass waste forms as defined above. 1.1.2 Test Method B is a durability test that allows testing at various test durations, test temperatures, mesh size, mass of sample, leachant volume, a...

  17. A permutation-based multiple testing method for time-course microarray experiments

    Directory of Open Access Journals (Sweden)

    George Stephen L

    2009-10-01

    Full Text Available Abstract Background Time-course microarray experiments are widely used to study the temporal profiles of gene expression. Storey et al. (2005 developed a method for analyzing time-course microarray studies that can be applied to discovering genes whose expression trajectories change over time within a single biological group, or those that follow different time trajectories among multiple groups. They estimated the expression trajectories of each gene using natural cubic splines under the null (no time-course and alternative (time-course hypotheses, and used a goodness of fit test statistic to quantify the discrepancy. The null distribution of the statistic was approximated through a bootstrap method. Gene expression levels in microarray data are often complicatedly correlated. An accurate type I error control adjusting for multiple testing requires the joint null distribution of test statistics for a large number of genes. For this purpose, permutation methods have been widely used because of computational ease and their intuitive interpretation. Results In this paper, we propose a permutation-based multiple testing procedure based on the test statistic used by Storey et al. (2005. We also propose an efficient computation algorithm. Extensive simulations are conducted to investigate the performance of the permutation-based multiple testing procedure. The application of the proposed method is illustrated using the Caenorhabditis elegans dauer developmental data. Conclusion Our method is computationally efficient and applicable for identifying genes whose expression levels are time-dependent in a single biological group and for identifying the genes for which the time-profile depends on the group in a multi-group setting.

  18. Applicability and interpretation of fracture test methods for metals

    International Nuclear Information System (INIS)

    Langford, W.J.

    1978-05-01

    Fracture tests are conducted usually out of a conviction (sometimes only vaguely defined) that they will guarantee a certain level of protecton from metal failure. Qualitative tests, such as the Charpy V-notch, produce results which cannot be rigorously related to a measure of fracture tolerance: rather, they indicate metal quality so that fracture tolerance may be inferred. Quantitative tests on the other hand provide parameters which may be used directly in equations to determine the likelihood of fracture. Both types of tests have limitations which should be understood: the paper tries to provide guidance on the relative merits of either approach for a particular purpose, and gives an insight into near-future test methods which will extend the range of usefullness of quantitative tests. (author)

  19. A method for the computation of turbulent polymeric liquids including hydrodynamic interactions and chain entanglements

    Energy Technology Data Exchange (ETDEWEB)

    Kivotides, Demosthenes, E-mail: demosthenes.kivotides@strath.ac.uk

    2017-02-12

    An asymptotically exact method for the direct computation of turbulent polymeric liquids that includes (a) fully resolved, creeping microflow fields due to hydrodynamic interactions between chains, (b) exact account of (subfilter) residual stresses, (c) polymer Brownian motion, and (d) direct calculation of chain entanglements, is formulated. Although developed in the context of polymeric fluids, the method is equally applicable to turbulent colloidal dispersions and aerosols. - Highlights: • An asymptotically exact method for the computation of polymer and colloidal fluids is developed. • The method is valid for all flow inertia and all polymer volume fractions. • The method models entanglements and hydrodynamic interactions between polymer chains.

  20. Development of calculation method for one-dimensional kinetic analysis in fission reactors, including feedback effects

    International Nuclear Information System (INIS)

    Paixao, S.B.; Marzo, M.A.S.; Alvim, A.C.M.

    1986-01-01

    The calculation method used in WIGLE code is studied. Because of the non availability of such a praiseworthy solution, expounding the method minutely has been tried. This developed method has been applied for the solution of the one-dimensional, two-group, diffusion equations in slab, axial analysis, including non-boiling heat transfer, accountig for feedback. A steady-state program (CITER-1D), written in FORTRAN 4, has been implemented, providing excellent results, ratifying the developed work quality. (Author) [pt

  1. Standard test method for splitting tensile strength for brittle nuclear waste forms

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1989-01-01

    1.1 This test method is used to measure the static splitting tensile strength of cylindrical specimens of brittle nuclear waste forms. It provides splitting tensile-strength data that can be used to compare the strength of waste forms when tests are done on one size of specimen. 1.2 The test method is applicable to glass, ceramic, and concrete waste forms that are sufficiently homogeneous (Note 1) but not to coated-particle, metal-matrix, bituminous, or plastic waste forms, or concretes with large-scale heterogeneities. Cementitious waste forms with heterogeneities >1 to 2 mm and 5 mm can be tested using this procedure provided the specimen size is increased from the reference size of 12.7 mm diameter by 6 mm length, to 51 mm diameter by 100 mm length, as recommended in Test Method C 496 and Practice C 192. Note 1—Generally, the specimen structural or microstructural heterogeneities must be less than about one-tenth the diameter of the specimen. 1.3 This test method can be used as a quality control chec...

  2. Review on applied foods and analyzed methods in identification testing of irradiated foods

    International Nuclear Information System (INIS)

    Kim, Kwang Hoon; Lee, Hoo Chul; Park, Sung Hyun; Kim, Soo Jin; Kim, Kwan Soo; Jeong, Il Yun; Lee, Ju Woon; Yook, Hong Sun

    2010-01-01

    Identification methods of irradiated foods have been adopted as official test by EU and Codex. PSL, TL, ESR and GC/MS methods were registered in Korea food code on 2009 and put in force as control system of verification for labelling of food irradiation. But most generally applicable PSL and TL methods are specified applicable foods according to domestic approved items. Unlike these specifications, foods unpermitted in Korea are included in applicable items of ESR and GC/MS methods. According to recent research data, numerous food groups are possible to effective legal control by identification and these items are demanded to permit regulations for irradiation additionally. Especially, the prohibition of irradiation for meats or seafoods is not harmonized with international standards and interacts as trade friction or industrial restrictions due to unprepared domestic regulation. Hence, extension of domestic legal permission for food irradiation can contrive to related industrial development and also can reduce trade friction and enhance international competitiveness

  3. THE USEFULNESS OF USER TESTING METHODS IN IDENTIFYING PROBLEMS ON UNIVERSITY WEBSITES

    Directory of Open Access Journals (Sweden)

    Layla Hasan

    2014-10-01

    Full Text Available This paper aims to investigate the usefulness of three user testing methods (observation, and using both quantitative and qualitative data from a post-test questionnaire in terms of their ability or inability to find specific usability problems on university websites. The results showed that observation was the best method, compared to the other two, in identifying large numbers of major and minor usability problems on university websites. The results also showed that employing qualitative data from a post-test questionnaire was a useful complementary method since this identified additional usability problems that were not identified by the observation method. However, the results showed that the quantitative data from the post-test questionnaire were inaccurate and ineffective in terms of identifying usability problems on such websites.

  4. Instrumentation and measurement method for the ATLAS test facility

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Byong Jo; Chu, In Chul; Eu, Dong Jin; Kang, Kyong Ho; Kim, Yeon Sik; Song, Chul Hwa; Baek, Won Pil

    2007-03-15

    An integral effect test loop for pressurized water reactors (PWRs), the ATLAS is constructed by thermal-hydraulic safety research division in KAERI. The ATLAS facility has been designed to have the length scale of 1/2 and area scale of 1/144 compared with the reference plant, APR1400 which is a Korean evolution type nuclear reactors. A total 1300 instrumentations is equipped in the ATLAS test facility. In this report, the instrumentation of ATLAS test facility and related measurement methods were introduced.

  5. Standard Test Method for Measuring Heat Flux Using a Water-Cooled Calorimeter

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the measurement of a steady heat flux to a given water-cooled surface by means of a system energy balance. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  6. Standard test method for measuring pH of soil for use in corrosion testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1995-01-01

    1.1 This test method covers a procedure for determining the pH of a soil in corrosion testing. The principle use of the test is to supplement soil resistivity measurements and thereby identify conditions under which the corrosion of metals in soil may be accentuated (see G 57 - 78 (1984)). 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  7. Development of laboratory acceleration test method for service life prediction of concrete structures

    International Nuclear Information System (INIS)

    Cho, M. S.; Song, Y. C.; Bang, K. S.; Lee, J. S.; Kim, D. K.

    1999-01-01

    Service life prediction of nuclear power plants depends on the application of history of structures, field inspection and test, the development of laboratory acceleration tests, their analysis method and predictive model. In this study, laboratory acceleration test method for service life prediction of concrete structures and application of experimental test results are introduced. This study is concerned with environmental condition of concrete structures and is to develop the acceleration test method for durability factors of concrete structures e.g. carbonation, sulfate attack, freeze-thaw cycles and shrinkage-expansion etc

  8. A Novel Vibration Mode Testing Method for Cylindrical Resonators Based on Microphones

    Directory of Open Access Journals (Sweden)

    Yongmeng Zhang

    2015-01-01

    Full Text Available Non-contact testing is an important method for the study of the vibrating characteristic of cylindrical resonators. For the vibratory cylinder gyroscope excited by piezo-electric electrodes, mode testing of the cylindrical resonator is difficult. In this paper, a novel vibration testing method for cylindrical resonators is proposed. This method uses a MEMS microphone, which has the characteristics of small size and accurate directivity, to measure the vibration of the cylindrical resonator. A testing system was established, then the system was used to measure the vibration mode of the resonator. The experimental results show that the orientation resolution of the node of the vibration mode is better than 0.1°. This method also has the advantages of low cost and easy operation. It can be used in vibration testing and provide accurate results, which is important for the study of the vibration mode and thermal stability of vibratory cylindrical gyroscopes.

  9. Comparison of methods for estimating the cost of human immunodeficiency virus-testing interventions.

    Science.gov (United States)

    Shrestha, Ram K; Sansom, Stephanie L; Farnham, Paul G

    2012-01-01

    The Centers for Disease Control and Prevention (CDC), Division of HIV/AIDS Prevention, spends approximately 50% of its $325 million annual human immunodeficiency virus (HIV) prevention funds for HIV-testing services. An accurate estimate of the costs of HIV testing in various settings is essential for efficient allocation of HIV prevention resources. To assess the costs of HIV-testing interventions using different costing methods. We used the microcosting-direct measurement method to assess the costs of HIV-testing interventions in nonclinical settings, and we compared these results with those from 3 other costing methods: microcosting-staff allocation, where the labor cost was derived from the proportion of each staff person's time allocated to HIV testing interventions; gross costing, where the New York State Medicaid payment for HIV testing was used to estimate program costs, and program budget, where the program cost was assumed to be the total funding provided by Centers for Disease Control and Prevention. Total program cost, cost per person tested, and cost per person notified of new HIV diagnosis. The median costs per person notified of a new HIV diagnosis were $12 475, $15 018, $2697, and $20 144 based on microcosting-direct measurement, microcosting-staff allocation, gross costing, and program budget methods, respectively. Compared with the microcosting-direct measurement method, the cost was 78% lower with gross costing, and 20% and 61% higher using the microcosting-staff allocation and program budget methods, respectively. Our analysis showed that HIV-testing program cost estimates vary widely by costing methods. However, the choice of a particular costing method may depend on the research question being addressed. Although program budget and gross-costing methods may be attractive because of their simplicity, only the microcosting-direct measurement method can identify important determinants of the program costs and provide guidance to improve

  10. Apparatus and test method for characterizing the temperature regulating properties of thermal functional porous polymeric materials.

    Science.gov (United States)

    Yao, Bao-Guo; Zhang, Shan; Zhang, De-Pin

    2017-05-01

    In order to evaluate the temperature regulating properties of thermal functional porous polymeric materials such as fabrics treated with phase change material microcapsules, a new apparatus was developed. The apparatus and the test method can measure the heat flux, temperature, and displacement signals during the dynamic contact and then quickly give an evaluation for the temperature regulating properties by simulating the dynamic heat transfer and temperature regulating process when the materials contact the body skin. A series of indices including the psychosensory intensity, regulating capability index, and relative regulating index were defined to characterize the temperature regulating properties. The measurement principle, the evaluation criteria and grading method, the experimental setup and the test results discussion, and the gage capability analysis of the apparatus are presented. The new apparatus provides a method for the objective measurement and evaluation of the temperature regulating properties of thermal functional porous polymeric materials.

  11. Drop Test Using Finite Element Method for Transport Package of Radioactive Material

    International Nuclear Information System (INIS)

    Xu Xiaoxiao; Zhao Bing; Zhang Jiangang; Li Gouqiang; Wang Xuexin; Tang Rongyao

    2010-01-01

    Mechanical test for transport package of radioactive material is one of the important tests for demonstrating package structure design. Drop test of package is a kind of destructive test. It is a common method of adopting the pre-analysis to determine drop orientation.Mechanical test of a sealed source package was calculated with finite element method (FEM) software. Based on the analysis of the calculation results, some values were obtained such as the stress, strain, acceleration and the drop orientation which causes the most severe damage, and the calculation results were compared with the results of test. (authors)

  12. Automatically stable discontinuous Petrov-Galerkin methods for stationary transport problems: Quasi-optimal test space norm

    KAUST Repository

    Niemi, Antti H.

    2013-12-01

    We investigate the application of the discontinuous Petrov-Galerkin (DPG) finite element framework to stationary convection-diffusion problems. In particular, we demonstrate how the quasi-optimal test space norm improves the robustness of the DPG method with respect to vanishing diffusion. We numerically compare coarse-mesh accuracy of the approximation when using the quasi-optimal norm, the standard norm, and the weighted norm. Our results show that the quasi-optimal norm leads to more accurate results on three benchmark problems in two spatial dimensions. We address the problems associated to the resolution of the optimal test functions with respect to the quasi-optimal norm by studying their convergence numerically. In order to facilitate understanding of the method, we also include a detailed explanation of the methodology from the algorithmic point of view. © 2013 Elsevier Ltd. All rights reserved.

  13. Automatically stable discontinuous Petrov-Galerkin methods for stationary transport problems: Quasi-optimal test space norm

    KAUST Repository

    Niemi, Antti H.; Collier, Nathan; Calo, Victor M.

    2013-01-01

    We investigate the application of the discontinuous Petrov-Galerkin (DPG) finite element framework to stationary convection-diffusion problems. In particular, we demonstrate how the quasi-optimal test space norm improves the robustness of the DPG method with respect to vanishing diffusion. We numerically compare coarse-mesh accuracy of the approximation when using the quasi-optimal norm, the standard norm, and the weighted norm. Our results show that the quasi-optimal norm leads to more accurate results on three benchmark problems in two spatial dimensions. We address the problems associated to the resolution of the optimal test functions with respect to the quasi-optimal norm by studying their convergence numerically. In order to facilitate understanding of the method, we also include a detailed explanation of the methodology from the algorithmic point of view. © 2013 Elsevier Ltd. All rights reserved.

  14. A multi-frequency fatigue testing method for wind turbine rotor blades

    Science.gov (United States)

    Eder, M. A.; Belloni, F.; Tesauro, A.; Hanis, T.

    2017-02-01

    Rotor blades are among the most delicate components of modern wind turbines. Reliability is a crucial aspect, since blades shall ideally remain free of failure under ultra-high cycle loading conditions throughout their designated lifetime of 20-25 years. Full-scale blade tests are the most accurate means to experimentally simulate damage evolution under operating conditions, and are therefore used to demonstrate that a blade type fulfils the reliability requirements to an acceptable degree of confidence. The state-of-the-art testing method for rotor blades in industry is based on resonance excitation where typically a rotating mass excites the blade close to its first natural frequency. During operation the blade response due to external forcing is governed by a weighted combination of its eigenmodes. Current test methodologies which only utilise the lowest eigenfrequency induce a fictitious damage where additional tuning masses are required to recover the desired damage distribution. Even with the commonly adopted amplitude upscaling technique fatigue tests remain a time-consuming and costly endeavour. The application of tuning masses increases the complexity of the problem by lowering the natural frequency of the blade and therefore increasing the testing time. The novel method presented in this paper aims at shortening the duration of the state-of-the-art fatigue testing method by simultaneously exciting the blade with a combination of two or more eigenfrequencies. Taking advantage of the different shapes of the excited eigenmodes, the actual spatial damage distribution can be more realistically simulated in the tests by tuning the excitation force amplitudes rather than adding tuning masses. This implies that in portions of the blade the lowest mode is governing the damage whereas in others higher modes contribute more significantly due to their higher cycle count. A numerical feasibility study based on a publicly available large utility rotor blade is used to

  15. Significance tests in mutagen screening: another method considering historical control frequencies

    International Nuclear Information System (INIS)

    Traut, H.

    1983-01-01

    Recently a method has been devised for testing the significance of the difference between a mutation frequency observed after chemical treatment or iradiation and the historical ('stable') control frequency. Another test is proposed serving the same purpose. Both methods are applied to several examples (experimental frequency versus historical control frequency). The results (P values) obtained agree well. (author)

  16. Testing the multi-configuration time-dependent Hartree-Fock method

    International Nuclear Information System (INIS)

    Zanghellini, Juergen; Kitzler, Markus; Brabec, Thomas; Scrinzi, Armin

    2004-01-01

    We test the multi-configuration time-dependent Hartree-Fock method as a new approach towards the numerical calculation of dynamical processes in multi-electron systems using the harmonic quantum dot and one-dimensional helium in strong laser pulses as models. We find rapid convergence for quantities such as ground-state population, correlation coefficient and single ionization towards the exact results. The method converges, where the time-dependent Hartree-Fock method fails qualitatively

  17. The anchors of steel wire ropes, testing methods and their results

    Directory of Open Access Journals (Sweden)

    J. Krešák

    2012-10-01

    Full Text Available The present paper introduces an application of the acoustic and thermographic method in the defectoscopic testing of immobile steel wire ropes at the most critical point, the anchor. First measurements and their results by these new defectoscopic methods are shown. In defectoscopic tests at the anchor, the widely used magnetic method gives unreliable results, and therefore presents a problem for steel wire defectoscopy. Application of the two new methods in the steel wire defectoscopy at the anchor point will enable increased safety measures at the anchor of steel wire ropes in bridge, roof, tower and aerial cable lift constructions.

  18. Test of a method for phase retrieval in HRTEM

    International Nuclear Information System (INIS)

    Beeching, M.J.; Spargo, A.E.C.

    1992-01-01

    Several methods of phase retrieval from the high resolution transmission electron microscopy image intensity distributions have been proposed but no standard method has emerged. The results achieved using a technique based on a development of the focus variation method, are reported. The dependence of the retrieved wavefunction on various experimental parameters is investigated and the method tested using computer simulated images. The method is shown to be useful in finding the complex wavefield at the exit surface of the specimen but the relationship of this to the specimen structure is considered as a separate issue. 1 ref., 3 figs

  19. Explaining Post-Communist Respect for Civil Liberty: A Multi-Methods Test

    DEFF Research Database (Denmark)

    Skaaning, Svend Erik

    2007-01-01

    This article explains the level of respect for civil liberty in post-communist countries. The methodological triangulation employs both QCA methods and OLS-regression to test the influence of structural conditions, the democratization literature emphasizes. The results show that the political leg...... the results of the methods applied diverge. Expect a lack of congruence given their different assumptions and logics. As to the QCA methods in specific, they are apparently valuable supplements, and at times even plausible alternatives, to standard statistical tests....

  20. Note on a simple test method for estimaing J/sub Ic/

    International Nuclear Information System (INIS)

    Whipple, T.A.; McHenry, H.I.

    1980-01-01

    Fracture toughness testing is generally a time-consuming and expensive procedure; therefore, there has been a significant amount of effort directed toward developing an inexpensive and rapid method of estimating the fracture toughness of materials. In this paper, a simple method for estimating J/sub Ic/ through the use of small, notched, bend bars is evaluated. The test only involves the measurement of the energy necessary to fracture the sample. Initial tests on Fe-18Cr-3Ni-13Mn and 304L stainless steel at 76 and 4 0 K have yielded results consistent with other fracture toughness tests, for materials in the low- to medium-toughness range

  1. DEPIVIH 2: Use of three HIV testing methods in French primary care settings - ELISA laboratory screening versus two rapid point-of-care HIV tests.

    Science.gov (United States)

    Papadima, D; Gauthier, R; Prévoteau du Clary, F; Bouée, S; Conort, G; Livrozet, J-M; Taulera, O; Wajsbrot, A; Majerholc, C; Peter, J-M; Aubert, J-P

    2018-03-01

    The primary endpoint was to evaluate the use of HIV testing methods by French primary care providers: Elisa laboratory screening, instant result HIV diagnostic test and rapid result HIV diagnostic test. The secondary endpoints were the population screening rate of unknown HIV status consulting during the study period, reasons for screening and for choosing the specific screening method, the investigators' satisfaction with the rapid diagnostic test (RDT) and problems encountered. National prospective interventional study with French family physicians (FP) from December 2013 to December 2014. FPs enrolled all consenting adults consulting for an HIV screening test during a 6-month period: the choice was an Elisa laboratory test or one of the two RDTs. During the study period, 43 FPs included 981 patients. HIV screening was performed for the first time for 31.6% of patients; 767 (78.2%) Elisa laboratory test prescriptions and 214 (21.8%) RDTs were performed, leading to a screening rate of 1.3%. For 120 (15.7%) of the Elisa laboratory tests, the result was not reported and six RDTs were not valid. Nine patients were diagnosed as HIV-infected (0.9%): five with Elisa laboratory test and four with RDT. Almost 90% of FPs were willing to keep on using RDTs in their daily practice. In general practice, RDTs may be an important additional tool to traditional HIV screening. They could account for one in five tests prescribed in this context. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  2. Research on Generating Method of Embedded Software Test Document Based on Dynamic Model

    Science.gov (United States)

    Qu, MingCheng; Wu, XiangHu; Tao, YongChao; Liu, Ying

    2018-03-01

    This paper provides a dynamic model-based test document generation method for embedded software that provides automatic generation of two documents: test requirements specification documentation and configuration item test documentation. This method enables dynamic test requirements to be implemented in dynamic models, enabling dynamic test demand tracking to be easily generated; able to automatically generate standardized, standardized test requirements and test documentation, improved document-related content inconsistency and lack of integrity And other issues, improve the efficiency.

  3. 16 CFR 1509.6 - Component-spacing test method.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Component-spacing test method. 1509.6 Section 1509.6 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT... applied to the wedge perpendicular to the plane of the crib side. ...

  4. Development and Testing of Physically-Based Methods for Filling Gaps in Remotely Sensed River Data

    Science.gov (United States)

    2011-09-30

    Filling Gaps in Remotely Sensed River Data Jonathan M. Nelson US Geological Survey National Research Program Geomorphology and Sediment Transport...the research work carried out under this grant are to develop and test two methods for filling in gaps in remotely sensed river data. The first...information, including suggestions for reducing this burden, to Washington Headquarters Services, Directorate for Information Operations and Reports, 1215

  5. Verification methods for treaties limiting and banning nuclear tests

    International Nuclear Information System (INIS)

    Voloshin, N.P.

    1998-01-01

    Treaty on limitation of underground nuclear weapon tests and treaty on world banning of nuclear tests contribute to and accompany the process of nuclear disarmament. Test ban in three (Moscow treaty of 1963) as well as the Threshold Test Ban up to 1991 was controlled only with national means. But since 1991 nuclear test threshold of 150 kt has been measured with hydrodynamic and tele seismic methods and checked by the inspection. Distinctive feature of this control is that control is that it is bilateral. This conforms to Treaty on limitation of underground nuclear weapon tests signed by two countries - USA and USSR. The inspection at the place of tests requires monitoring of the test site of the party conducting a test and geological information of rock in the area of explosion. In the treaty of the World Nuclear Test Ban the following ways of international control are provided for: - seismologic measurements; - radionuclide measurements; - hydro-acoustics measurements; - infra-sound measurements; - inspection at the place of the tests conduction

  6. Complete Tangent Stiffness for eXtended Finite Element Method by including crack growth parameters

    DEFF Research Database (Denmark)

    Mougaard, J.F.; Poulsen, P.N.; Nielsen, L.O.

    2013-01-01

    the crack geometry parameters, such as the crack length and the crack direction directly in the virtual work formulation. For efficiency, it is essential to obtain a complete tangent stiffness. A new method in this work is presented to include an incremental form the crack growth parameters on equal terms......The eXtended Finite Element Method (XFEM) is a useful tool for modeling the growth of discrete cracks in structures made of concrete and other quasi‐brittle and brittle materials. However, in a standard application of XFEM, the tangent stiffness is not complete. This is a result of not including...... with the degrees of freedom in the FEM‐equations. The complete tangential stiffness matrix is based on the virtual work together with the constitutive conditions at the crack tip. Introducing the crack growth parameters as direct unknowns, both equilibrium equations and the crack tip criterion can be handled...

  7. Method-independent, Computationally Frugal Convergence Testing for Sensitivity Analysis Techniques

    Science.gov (United States)

    Mai, J.; Tolson, B.

    2017-12-01

    The increasing complexity and runtime of environmental models lead to the current situation that the calibration of all model parameters or the estimation of all of their uncertainty is often computationally infeasible. Hence, techniques to determine the sensitivity of model parameters are used to identify most important parameters. All subsequent model calibrations or uncertainty estimation procedures focus then only on these subsets of parameters and are hence less computational demanding. While the examination of the convergence of calibration and uncertainty methods is state-of-the-art, the convergence of the sensitivity methods is usually not checked. If any, bootstrapping of the sensitivity results is used to determine the reliability of the estimated indexes. Bootstrapping, however, might as well become computationally expensive in case of large model outputs and a high number of bootstraps. We, therefore, present a Model Variable Augmentation (MVA) approach to check the convergence of sensitivity indexes without performing any additional model run. This technique is method- and model-independent. It can be applied either during the sensitivity analysis (SA) or afterwards. The latter case enables the checking of already processed sensitivity indexes. To demonstrate the method's independency of the convergence testing method, we applied it to two widely used, global SA methods: the screening method known as Morris method or Elementary Effects (Morris 1991) and the variance-based Sobol' method (Solbol' 1993). The new convergence testing method is first scrutinized using 12 analytical benchmark functions (Cuntz & Mai et al. 2015) where the true indexes of aforementioned three methods are known. This proof of principle shows that the method reliably determines the uncertainty of the SA results when different budgets are used for the SA. The results show that the new frugal method is able to test the convergence and therefore the reliability of SA results in an

  8. Flight Test Results of a GPS-Based Pitot-Static Calibration Method Using Output-Error Optimization for a Light Twin-Engine Airplane

    Science.gov (United States)

    Martos, Borja; Kiszely, Paul; Foster, John V.

    2011-01-01

    As part of the NASA Aviation Safety Program (AvSP), a novel pitot-static calibration method was developed to allow rapid in-flight calibration for subscale aircraft while flying within confined test areas. This approach uses Global Positioning System (GPS) technology coupled with modern system identification methods that rapidly computes optimal pressure error models over a range of airspeed with defined confidence bounds. This method has been demonstrated in subscale flight tests and has shown small 2- error bounds with significant reduction in test time compared to other methods. The current research was motivated by the desire to further evaluate and develop this method for full-scale aircraft. A goal of this research was to develop an accurate calibration method that enables reductions in test equipment and flight time, thus reducing costs. The approach involved analysis of data acquisition requirements, development of efficient flight patterns, and analysis of pressure error models based on system identification methods. Flight tests were conducted at The University of Tennessee Space Institute (UTSI) utilizing an instrumented Piper Navajo research aircraft. In addition, the UTSI engineering flight simulator was used to investigate test maneuver requirements and handling qualities issues associated with this technique. This paper provides a summary of piloted simulation and flight test results that illustrates the performance and capabilities of the NASA calibration method. Discussion of maneuver requirements and data analysis methods is included as well as recommendations for piloting technique.

  9. High level helium leak testing methods developed at ICSI Rm. Valcea

    International Nuclear Information System (INIS)

    Saros, Gili; Armeanu, Adrian; Saros, Irina; Ciortea, Constantin

    2007-01-01

    Full text: Helium leak detection is one of the most widely used methods of nondestructive testing in use today. In principle two methods are applied for leak testing and localization of leaks, the 'Vacuum method' and the 'Overpressure method'. In case of the 'Vacuum method' the object to be examined for leaks is evacuated and filled instead with Helium. The gas penetrates through any leaks found in the object and is detected by the leak test instrument. In case of the 'Overpressure method' the object to be examined for leaks is filled with Helium, under slight overpressure. The gas escapes through any leaks present and it is detected by a detector probe. This detector probe sometimes called a 'sniffer' acting as a gas sampling probe. Varian 979 Helium Leak Detector has a built-in turbo pump and an externally mounted dry forepump located below the system. The leak detector is configured for the evacuation type leak testing. In this case, the vacuum system under test is evacuated by the leak detector. Helium is then sprayed on the outside of the vacuum system and is pumped into the leak detector if a leak is present. The leak detector is capable to detect leaks down to 10 -9 atm-cc/sec range. The Specton 300E is a strong, rugged leak detector designed to operate in dirty industrial conditions as well as clean research areas. A number of applications are mentioned: - Generators; - Buried Pipelines; - Chemical and power plants; - Vacuum furnace installations; - Heat Exchangers; - Tank Floors; - Nuclear research centers; - Refrigeration installations; - Any type of industrial vacuum system. (authors)

  10. High sensitive quench detection method using an integrated test wire

    International Nuclear Information System (INIS)

    Fevrier, A.; Tavergnier, J.P.; Nithart, H.; Kiblaire, M.; Duchateau, J.L.

    1981-01-01

    A high sensitive quench detection method which works even in the presence of an external perturbing magnetic field is reported. The quench signal is obtained from the difference in voltages at the superconducting winding terminals and at the terminals at a secondary winding strongly coupled to the primary. The secondary winding could consist of a ''zero-current strand'' of the superconducting cable not connected to one of the winding terminals or an integrated normal test wire inside the superconducting cable. Experimental results on quench detection obtained by this method are described. It is shown that the integrated test wire method leads to efficient and sensitive quench detection, especially in the presence of an external perturbing magnetic field

  11. NNWSI waste form test method for unsaturated disposal conditions

    International Nuclear Information System (INIS)

    Bates, J.K.; Gerding, T.J.

    1985-03-01

    A test method has been developed to measure the release of radionuclides from the waste package under simulated NNWSI repository conditions, and to provide information concerning materials interactions that may occur in the repository. Data are presented from Unsaturated testing of simulated Savannah River Laboratory 165 glass completed through 26 weeks. The relationship between these results and those from parametric and analog testing are described. The data indicate that the waste form test is capable of producing consistent, reproducible results that will be useful in evaluating the role of the waste package in the long-term performance of the repository. 6 refs., 7 figs., 5 tabs

  12. Testing Faith: A Mixed Methods Study Investigating the Relationship between Prayer and Test Anxiety amongst College Students

    Science.gov (United States)

    Campbell, Drey

    2016-01-01

    Test anxiety is problem that affects college students. Explanatory mixed methods research was completed with the objective of understanding the interrelationship of prayer and test anxiety as well as the potential therapeutic effects of Christian prayer on test anxiety. It was hypothesized that Christian prayer would have significant effects on…

  13. 2-d Simulations of Test Methods

    DEFF Research Database (Denmark)

    Thrane, Lars Nyholm

    2004-01-01

    One of the main obstacles for the further development of self-compacting concrete is to relate the fresh concrete properties to the form filling ability. Therefore, simulation of the form filling ability will provide a powerful tool in obtaining this goal. In this paper, a continuum mechanical...... approach is presented by showing initial results from 2-d simulations of the empirical test methods slump flow and L-box. This method assumes a homogeneous material, which is expected to correspond to particle suspensions e.g. concrete, when it remains stable. The simulations have been carried out when...... using both a Newton and Bingham model for characterisation of the rheological properties of the concrete. From the results, it is expected that both the slump flow and L-box can be simulated quite accurately when the model is extended to 3-d and the concrete is characterised according to the Bingham...

  14. Standard test method for analysis of isotopic composition of uranium in nuclear-grade fuel material by quadrupole inductively coupled plasma-mass spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This test method is applicable to the determination of the isotopic composition of uranium (U) in nuclear-grade fuel material. The following isotopic weight percentages are determined using a quadrupole inductively coupled plasma-mass spectrometer (Q-ICP-MS): 233U, 234U, 235U, 236U, and 238U. The analysis can be performed on various material matrices after acid dissolution and sample dilution into water or dilute nitric (HNO3) acid. These materials include: fuel product, uranium oxide, uranium oxide alloys, uranyl nitrate (UNH) crystals, and solutions. The sample preparation discussed in this test method focuses on fuel product material but may be used for uranium oxide or a uranium oxide alloy. Other preparation techniques may be used and some references are given. Purification of the uranium by anion-exchange extraction is not required for this test method, as it is required by other test methods such as radiochemistry and thermal ionization mass spectroscopy (TIMS). This test method is also described i...

  15. Development of a suitable test method for evaluating the toxicity of contaminated soils to earthworms in Canada

    Energy Technology Data Exchange (ETDEWEB)

    Stephenson, G.L. [Univ. of Guelph, Ontario (Canada); Scroggins, R. [Environment Canada, Gloucester, Ontario (Canada). Method Development and Application Section

    1995-12-31

    Environment Canada has embarked on a five year program to develop, standardize, and validate a battery of soil toxicity tests which can be used to assess the relative toxicity of contaminants in soils to terrestrial organisms. These tests must be applicable to soil conditions typically found in Canadian environments and the test species must be representative of the species of soil invertebrates or plants inhabiting soil ecosystems in Canada. One of the toxicity tests being developed is designed to assess the toxicity of contaminated soils to earthworms. Five of the potential test species belong to the Lumbricidae family and include the Canadian worm (Allobophora calignosa/Aporrectodea tuberculate), the European bark worm (Dendrodtilus rubidus (rubida)), the pink soil worm (Eisenia rosea), the red marsh worm (Lumbricus rubellus), and the Canadian night crawler or dew worm (Lumbricus terrestris). The sixth species, the white pot worm (Enchytraeus albidus), belongs to the Enchytraeidae family. Further assessment reduced the number of representative species to three. Most earthworm test methods have been developed to assess the toxicity of chemically-spiked artificial soils to Eisenia fetida or E. andrei. Test methods have also been developed to assess the relative toxicity of contaminated soils from hazardous waste sites. Comparative acute toxicity data for three species of earthworm exposed to a hydrocarbon contamination will be presented. Comparative toxicity data for the same three species of earthworm will also be presented using test procedures and conditions that have been modified to accommodate biological differences among the species of earthworm. Recommendations regarding test design, methods, and conditions optimal for each test species will be summarized and discussed with respect to the precision of test results.

  16. Disintegration of sublingual tablets: proposal for a validated test method and acceptance criterion.

    Science.gov (United States)

    Weda, M; van Riet-Nales, D A; van Aalst, P; de Kaste, D; Lekkerkerker, J F F

    2006-12-01

    In the Netherlands the market share of isosorbide dinitrate 5 mg sublingual tablets is dominated by 2 products (A and B). In the last few years complaints have been received from health care professionals on product B. During patient use the disintegration of the tablet was reported to be slow and/or incomplete, and ineffectiveness was experienced. In the European Pharmacopoeia (Ph. Eur.) no requirement is present for the disintegration time of sublingual tablets. The purpose of this study was to compare the in vitro disintegration time of products A and B, and to establish a suitable test method and acceptance criterion. A and B were tested with the Ph. Eur. method described in the monograph on disintegration of tablets and capsules as well as with 3 modified tests using the same Ph. Eur. apparatus, but without movement of the basket-rack assembly. In modified test 1 and modified test 2 water was used as medium (900 ml and 50 ml respectively), whereas in modified test 3 artificial saliva was used (50 ml). In addition, disintegration was tested in Nessler tubes with 0.5 and 2 ml of water. Finally, the Ph. Eur. method was also applied to other sublingual tablets with other drug substances on the Dutch market. With modified test 3 no disintegration could be achieved within 20 min. With the Ph. Eur. method and modified tests 1 and 2 product A and B differed significantly (p disintegration times. These 3 methods were capable of discriminating between products and between batches. The time measured with the Ph. Eur. method was significantly lower compared to modified tests 1 and 2 (p tablets the disintegration time should be tested. The Ph. Eur. method is considered suitable for this test. In view of the products currently on the market and taking into consideration requirements in the United States Pharmacopeia and Japanese Pharmacopoeia, an acceptance criterion of not more than 2 min is proposed.

  17. Design of New Test Function Model Based on Multi-objective Optimization Method

    Directory of Open Access Journals (Sweden)

    Zhaoxia Shang

    2017-01-01

    Full Text Available Space partitioning method, as a new algorism, has been applied to planning and decision-making of investment portfolio more and more often. But currently there are so few testing function for this algorism, which has greatly restrained its further development and application. An innovative test function model is designed in this paper and is used to test the algorism. It is proved that for evaluation of space partitioning method in certain applications, this test function has fairly obvious advantage.

  18. Results of a Saxitoxin Proficiency Test Including Characterization of Reference Material and Stability Studies

    Directory of Open Access Journals (Sweden)

    Kirsi Harju

    2015-11-01

    Full Text Available A saxitoxin (STX proficiency test (PT was organized as part of the Establishment of Quality Assurance for the Detection of Biological Toxins of Potential Bioterrorism Risk (EQuATox project. The aim of this PT was to provide an evaluation of existing methods and the European laboratories’ capabilities for the analysis of STX and some of its analogues in real samples. Homogenized mussel material and algal cell materials containing paralytic shellfish poisoning (PSP toxins were produced as reference sample matrices. The reference material was characterized using various analytical methods. Acidified algal extract samples at two concentration levels were prepared from a bulk culture of PSP toxins producing dinoflagellate Alexandrium ostenfeldii. The homogeneity and stability of the prepared PT samples were studied and found to be fit-for-purpose. Thereafter, eight STX PT samples were sent to ten participating laboratories from eight countries. The PT offered the participating laboratories the possibility to assess their performance regarding the qualitative and quantitative detection of PSP toxins. Various techniques such as official Association of Official Analytical Chemists (AOAC methods, immunoassays, and liquid chromatography-mass spectrometry were used for sample analyses.

  19. SU-F-T-249: Application of Human Factors Methods: Usability Testing in the Radiation Oncology Environment

    International Nuclear Information System (INIS)

    Warkentin, H; Bubric, K; Giovannetti, H; Graham, G; Clay, C

    2016-01-01

    Purpose: As a quality improvement measure, we undertook this work to incorporate usability testing into the implementation procedures for new electronic documents and forms used by four affiliated radiation therapy centers. Methods: A human factors specialist provided training in usability testing for a team of medical physicists, radiation therapists, and radiation oncologists from four radiotherapy centers. A usability testing plan was then developed that included controlled scenarios and standardized forms for qualitative and quantitative feedback from participants, including patients. Usability tests were performed by end users using the same hardware and viewing conditions that are found in the clinical environment. A pilot test of a form used during radiotherapy CT simulation was performed in a single department; feedback informed adaptive improvements to the electronic form, hardware requirements, resource accessibility and the usability testing plan. Following refinements to the testing plan, usability testing was performed at three affiliated cancer centers with different vault layouts and hardware. Results: Feedback from the testing resulted in the detection of 6 critical errors (omissions and inability to complete task without assistance), 6 non-critical errors (recoverable), and multiple suggestions for improvement. Usability problems with room layout were detected at one center and problems with hardware were detected at one center. Upon amalgamation and summary of the results, three key recommendations were presented to the document’s authors for incorporation into the electronic form. Documented inefficiencies and patient safety concerns related to the room layout and hardware were presented to administration along with a request for funding to purchase upgraded hardware and accessories to allow a more efficient workflow within the simulator vault. Conclusion: By including usability testing as part of the process when introducing any new document

  20. SU-F-T-249: Application of Human Factors Methods: Usability Testing in the Radiation Oncology Environment

    Energy Technology Data Exchange (ETDEWEB)

    Warkentin, H [Cross Cancer Institute, Edmonton, AB (Canada); Bubric, K [Alberta Health Services, Calgary, AB (Canada); Giovannetti, H [Jack Ady Cancer Centre, Lethbridge, AB (Canada); Graham, G [Tom Baker Cancer Centre, Calgary, AB (Canada); Clay, C [Central Alberta Cancer Centre, Red Deer, AB (Canada)

    2016-06-15

    Purpose: As a quality improvement measure, we undertook this work to incorporate usability testing into the implementation procedures for new electronic documents and forms used by four affiliated radiation therapy centers. Methods: A human factors specialist provided training in usability testing for a team of medical physicists, radiation therapists, and radiation oncologists from four radiotherapy centers. A usability testing plan was then developed that included controlled scenarios and standardized forms for qualitative and quantitative feedback from participants, including patients. Usability tests were performed by end users using the same hardware and viewing conditions that are found in the clinical environment. A pilot test of a form used during radiotherapy CT simulation was performed in a single department; feedback informed adaptive improvements to the electronic form, hardware requirements, resource accessibility and the usability testing plan. Following refinements to the testing plan, usability testing was performed at three affiliated cancer centers with different vault layouts and hardware. Results: Feedback from the testing resulted in the detection of 6 critical errors (omissions and inability to complete task without assistance), 6 non-critical errors (recoverable), and multiple suggestions for improvement. Usability problems with room layout were detected at one center and problems with hardware were detected at one center. Upon amalgamation and summary of the results, three key recommendations were presented to the document’s authors for incorporation into the electronic form. Documented inefficiencies and patient safety concerns related to the room layout and hardware were presented to administration along with a request for funding to purchase upgraded hardware and accessories to allow a more efficient workflow within the simulator vault. Conclusion: By including usability testing as part of the process when introducing any new document

  1. Development of test practice requirements for a standard method on fracture toughness testing in the transition range

    International Nuclear Information System (INIS)

    McCabe, D.E.; Zerbst, U.; Heerens, J.

    1993-01-01

    This report covers the resolution of several issues that are relevant to the ductile to brittle transition range of structural steels. One of this issues was to compare a statistical-based weakest-link method to constraint data adjustment methods for modeling the specimen size effects on fracture toughness. Another was to explore the concept of a universal transition temperature curve shape (Master Curve). Data from a Materials Properties Council round robin activity were used to test the proposals empirically. The findings of this study are inclosed in an activity for the development of a draft standard test procedure ''Test Practice for Fracture Toughness in the Transition Range''. (orig.) [de

  2. Evaluation of semisolid agar method for antifungal susceptibility test of T. rubrum

    Directory of Open Access Journals (Sweden)

    Sultana Razia

    2016-08-01

    Full Text Available Background: With increasing fungal disease many newer antifungal drugs are available with different spectrum of activ­ity. Antifungal susceptibility test will help clinicians for selection of effective drug and thereby treatment of patient. Objective: The study was undertaken to perform a simple screening drug susceptibility test of T. rnbrum by Semi Solid Agar Antifungal Susceptibility (SAAS Method: Perfonnance of susceptibility method was assessed by comparing the MICs of three commonly prescribed antifungal agents namely- tluconazole (FCZ, itraconazole (ITZ and terbinafine (TER to the CLSI (Clinical and Laboratory Standard Institute recommended M-38, a broth microdilution method. Results: In SAAS method, among twenty nine T. rubrum, twenty five (86.2% were susceptible (MIC range 0.5-64 µg/ml to Fluconazole (FCZ and four (13.7% were resistant (MIC value >64 µg/ml. In broth microdilution method, among twenty nine T. rubrum, twenty six (89.6% were susceptible (MIC range 0.3-64 µg/ml to FCZ and three (10.3% were resistant (MIC value >64 µg/ml. In case of both ITZ and TER, all were susceptible (MIC range 0.3-64 µg/ml to both methods. The SAAS method demonstrated the susceptibility pattern of T. rubrum against FCZ, ITZ and TER usually within 72 to 96 hours after organism isolation and results were concordance with the results of CLSI broth microdilution method. Conclusion: Though it is a newer method with proper standardization of the test method, SAAS method is simple and easily applicable screening method for susceptibility testing of antifungal agents against dermatophytes in any microbiology laboratories.

  3. Towards Automatic Testing of Reference Point Based Interactive Methods

    OpenAIRE

    Ojalehto, Vesa; Podkopaev, Dmitry; Miettinen, Kaisa

    2016-01-01

    In order to understand strengths and weaknesses of optimization algorithms, it is important to have access to different types of test problems, well defined performance indicators and analysis tools. Such tools are widely available for testing evolutionary multiobjective optimization algorithms. To our knowledge, there do not exist tools for analyzing the performance of interactive multiobjective optimization methods based on the reference point approach to communicating ...

  4. Method and apparatus for controlling a powertrain system including a multi-mode transmission

    Science.gov (United States)

    Hessell, Steven M.; Morris, Robert L.; McGrogan, Sean W.; Heap, Anthony H.; Mendoza, Gil J.

    2015-09-08

    A powertrain including an engine and torque machines is configured to transfer torque through a multi-mode transmission to an output member. A method for controlling the powertrain includes employing a closed-loop speed control system to control torque commands for the torque machines in response to a desired input speed. Upon approaching a power limit of a power storage device transferring power to the torque machines, power limited torque commands are determined for the torque machines in response to the power limit and the closed-loop speed control system is employed to determine an engine torque command in response to the desired input speed and the power limited torque commands for the torque machines.

  5. Quality-control analytical methods: endotoxins: essential testing for pyrogens in the compounding laboratory, part 3: a simplified endotoxin test method for compounded sterile preparations.

    Science.gov (United States)

    Cooper, James F

    2011-01-01

    The first two parts of the IJPC series on endotoxin testing explained the nature of pyrogenic contamination and described various Limulus amebocyte lysate methods for detecting and measuring endotoxin levels with the bacterial endotoxin test described in the United States Pharmacopeia. This third article in that series describes the endotoxin test that is simplest to permorm for pharmacists who prefer to conduct an endotoxin assa at the time of compounding in the pharmacy setting.

  6. Accelerated test techniques for micro-circuits: Evaluation of high temperature (473 k - 573 K) accelerated life test techniques as effective microcircuit screening methods

    Science.gov (United States)

    Johnson, G. M.

    1976-01-01

    The application of high temperature accelerated test techniques was shown to be an effective method of microcircuit defect screening. Comprehensive microcircuit evaluations and a series of high temperature (473 K to 573 K) life tests demonstrated that a freak or early failure population of surface contaminated devices could be completely screened in thirty two hours of test at an ambient temperature of 523 K. Equivalent screening at 398 K, as prescribed by current Military and NASA specifications, would have required in excess of 1,500 hours of test. All testing was accomplished with a Texas Instruments' 54L10, low power triple-3 input NAND gate manufactured with a titanium- tungsten (Ti-W), Gold (Au) metallization system. A number of design and/or manufacturing anomalies were also noted with the Ti-W, Au metallization system. Further study of the exact nature and cause(s) of these anomalies is recommended prior to the use of microcircuits with Ti-W, Au metallization in long life/high reliability applications. Photomicrographs of tested circuits are included.

  7. Comparison of Three Different Methods for Pile Integrity Testing on a Cylindrical Homogeneous Polyamide Specimen

    Science.gov (United States)

    Lugovtsova, Y. D.; Soldatov, A. I.

    2016-01-01

    Three different methods for pile integrity testing are proposed to compare on a cylindrical homogeneous polyamide specimen. The methods are low strain pile integrity testing, multichannel pile integrity testing and testing with a shaker system. Since the low strain pile integrity testing is well-established and standardized method, the results from it are used as a reference for other two methods.

  8. Reliability and limitation of various diagnostic methods including nuclear medicine in myocardial disease

    International Nuclear Information System (INIS)

    Tokuyasu, Yoshiki; Kusakabe, Kiyoko; Yamazaki, Toshio

    1981-01-01

    Electrocardiography (ECG), echocardiography, nuclear method, cardiac catheterization, left ventriculography and endomyocardial biopsy (biopsy) were performed in 40 cases of cardiomyopathy (CM), 9 of endocardial fibroelastosis and 19 of specific heart muscle disease, and the usefulness and limitation of each method was comparatively estimated. In CM, various methods including biopsy were performed. The 40 patients were classified into 3 groups, i.e., hypertrophic (17), dilated (20) and non-hypertrophic.non-dilated (3) on the basis of left ventricular ejection fraction and hypertrophy of the ventricular wall. The hypertrophic group was divided into 4 subgroups: 9 septal, 4 apical, 2 posterior and 2 anterior. The nuclear study is useful in assessing the site of the abnormal ventricular thickening, perfusion defect and ventricular function. Echocardiography is most useful in detecting asymmetric septal hypertrophy. The biopsy gives the sole diagnostic clue, especially in non-hypertrophic.non-dilated cardiomyopathy. ECG is useful in all cases but correlation with the site of disproportional hypertrophy was not obtained. (J.P.N.)

  9. Standard Test Method for Calibration of Non-Concentrator Photovoltaic Secondary Reference Cells

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers calibration and characterization of secondary terrestrial photovoltaic reference cells to a desired reference spectral irradiance distribution. The recommended physical requirements for these reference cells are described in Specification E1040. Reference cells are principally used in the determination of the electrical performance of a photovoltaic device. 1.2 Secondary reference cells are calibrated indoors using simulated sunlight or outdoors in natural sunlight by reference to a primary reference cell previously calibrated to the same desired reference spectral irradiance distribution. 1.3 Secondary reference cells calibrated according to this test method will have the same radiometric traceability as the of the primary reference cell used for the calibration. Therefore, if the primary reference cell is traceable to the World Radiometric Reference (WRR, see Test Method E816), the resulting secondary reference cell will also be traceable to the WRR. 1.4 This test method appli...

  10. 40 CFR Appendix B to Part 80 - Test Methods for Lead in Gasoline

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Test Methods for Lead in Gasoline B... in Gasoline Method 1—Standard Method Test for Lead in Gasoline by Atomic Absorption Spectrometry 1. Scope. 1.1. This method covers the determination of the total lead content of gasoline. The procedure's...

  11. Accelerated in-vitro release testing methods for extended-release parenteral dosage forms.

    Science.gov (United States)

    Shen, Jie; Burgess, Diane J

    2012-07-01

    This review highlights current methods and strategies for accelerated in-vitro drug release testing of extended-release parenteral dosage forms such as polymeric microparticulate systems, lipid microparticulate systems, in-situ depot-forming systems and implants. Extended-release parenteral dosage forms are typically designed to maintain the effective drug concentration over periods of weeks, months or even years. Consequently, 'real-time' in-vitro release tests for these dosage forms are often run over a long time period. Accelerated in-vitro release methods can provide rapid evaluation and therefore are desirable for quality control purposes. To this end, different accelerated in-vitro release methods using United States Pharmacopeia (USP) apparatus have been developed. Different mechanisms of accelerating drug release from extended-release parenteral dosage forms, along with the accelerated in-vitro release testing methods currently employed are discussed. Accelerated in-vitro release testing methods with good discriminatory ability are critical for quality control of extended-release parenteral products. Methods that can be used in the development of in-vitro-in-vivo correlation (IVIVC) are desirable; however, for complex parenteral products this may not always be achievable. © 2012 The Authors. JPP © 2012 Royal Pharmaceutical Society.

  12. Accelerated in vitro release testing methods for extended release parenteral dosage forms

    Science.gov (United States)

    Shen, Jie; Burgess, Diane J.

    2012-01-01

    Objectives This review highlights current methods and strategies for accelerated in vitro drug release testing of extended release parenteral dosage forms such as polymeric microparticulate systems, lipid microparticulate systems, in situ depot-forming systems, and implants. Key findings Extended release parenteral dosage forms are typically designed to maintain the effective drug concentration over periods of weeks, months or even years. Consequently, “real-time” in vitro release tests for these dosage forms are often run over a long time period. Accelerated in vitro release methods can provide rapid evaluation and therefore are desirable for quality control purposes. To this end, different accelerated in vitro release methods using United States Pharmacopoeia (USP) apparatus have been developed. Different mechanisms of accelerating drug release from extended release parenteral dosage forms, along with the accelerated in vitro release testing methods currently employed are discussed. Conclusions Accelerated in vitro release testing methods with good discriminatory ability are critical for quality control of extended release parenteral products. Methods that can be used in the development of in vitro-in vivo correlation (IVIVC) are desirable, however for complex parenteral products this may not always be achievable. PMID:22686344

  13. Hydrocoin level 3 - Testing methods for sensitivity/uncertainty analysis

    International Nuclear Information System (INIS)

    Grundfelt, B.; Lindbom, B.; Larsson, A.; Andersson, K.

    1991-01-01

    The HYDROCOIN study is an international cooperative project for testing groundwater hydrology modelling strategies for performance assessment of nuclear waste disposal. The study was initiated in 1984 by the Swedish Nuclear Power Inspectorate and the technical work was finalised in 1987. The participating organisations are regulatory authorities as well as implementing organisations in 10 countries. The study has been performed at three levels aimed at studying computer code verification, model validation and sensitivity/uncertainty analysis respectively. The results from the first two levels, code verification and model validation, have been published in reports in 1988 and 1990 respectively. This paper focuses on some aspects of the results from Level 3, sensitivity/uncertainty analysis, for which a final report is planned to be published during 1990. For Level 3, seven test cases were defined. Some of these aimed at exploring the uncertainty associated with the modelling results by simply varying parameter values and conceptual assumptions. In other test cases statistical sampling methods were applied. One of the test cases dealt with particle tracking and the uncertainty introduced by this type of post processing. The amount of results available is substantial although unevenly spread over the test cases. It has not been possible to cover all aspects of the results in this paper. Instead, the different methods applied will be illustrated by some typical analyses. 4 figs., 9 refs

  14. Method and equipment for treating waste water resulting from the technological testing processes of NPP equipment

    International Nuclear Information System (INIS)

    Radulescu, M. C.; Valeca, S.; Iorga, C.

    2016-01-01

    Modern methods and technologies coupled together with advanced equipment for treating residual substances resulted from technological processes are mandatory measures for all industrial facilities. The correct management of the used working agents and of the all wastes resulted from the different technological process (preparation, use, collection, neutralization, discharge) is intended to reduce up to removal of their potential negative impact on the environment. The high pressure and temperature testing stands from INR intended for functional testing of nuclear components (fuel bundles, fuelling machines, etc.) were included in these measures since the use of oils, demineralized water chemically treated, greases, etc. This paper is focused on the method and equipment used at INR Pitesti in the chemical treatment of demineralized waters, as well as the equipment for collecting, neutralizing and discharging them after use. (authors)

  15. Standard test method for uranium by Iron (II) reduction in phosphoric acid followed by chromium (VI) titration in the presence of vanadium

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method, commonly referred to as the Modified Davies and Gray technique, covers the titration of uranium in product, fuel, and scrap materials after the material is dissolved. The test method is versatile and has been ruggedness tested. With appropriate sample preparation, this test method can give precise and unbiased uranium assays over a wide variety of material types (1, 2). Details of the titration procedure in the presence of plutonium with appropriate modifications are given in Test Method C1204. 1.2 Uranium levels titrated are usually 20 to 50 mg, but up to 200 mg uranium can be titrated using the reagent volumes stated in this test method. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determ...

  16. A New Testing Method for Lifetime Prediction of Automotive Exhaust Silencers

    Directory of Open Access Journals (Sweden)

    Muhammad Yasir

    2011-01-01

    Full Text Available The purpose of this paper is to highlight the problems associated with daily routine corrosion tests performed in an automotive exhaust industry. Estimation of the life time of a complete system under real conditions is always uncertain and often leads to a disagreement. A new testing setup was built in which simulation of external and internal corrosion with additional thermal cycles can be performed simultaneously. Simulation of all real conditions makes this test totally versatile and unique among all the existing testing methods. All test results were investigated quantitatively and a direct comparison was made between some field systems with different mileage and total life. Conformity was accomplished between the results from corrosion tests and parts from the vehicles. Studies carried out on the silencers have shown that the new component testing method could be used for life time estimation of parts having different material and design combinations. On the basis of obtained results it can be stated that the new testing setup can be applied for different materials and design rankings.

  17. Method of test signal design for estimating the aircraft aerodynamic parameters

    Science.gov (United States)

    Belokon', S. A.; Zolotukhin, Yu. N.; Filippov, M. N.

    2017-07-01

    A method of test signal design is proposed for studying the aircraft aerodynamic characteristics with the use of the technology of dynamically scaled free-flight models. Simultaneous excitation of all input channels in a prescribed frequency band by a set of mutually orthogonal signals is applied to increase the efficiency. A modified method of calculating the set of mutually orthogonal sinusoidal signals with a small normalized peak factor is presented. Results of simulating the aircraft motion in the MATLAB/Simulink environment with the use of the developed method of test signal design are reported.

  18. New method of thermal cycling stability test of phase change material

    Directory of Open Access Journals (Sweden)

    Putra Nandy

    2017-01-01

    Full Text Available Phase Change Material (PCM is the most promising material as thermal energy storage nowadays. As thermal energy storage, examination on endurance of material for long-term use is necessary to be carried out. Therefore, thermal cycling test is performed to ensure thermal stability of PCM. This study have found a new method on thermal cycling test of PCM sample by using thermoelectric as heating and cooling element. RT 22 HC was used as PCM sample on this thermal cycling test. The new method had many advantages compared to some references of the same test. It just needed a small container for PCM sample. The thermoelectric could release heat to PCM sample and absorb heat from PCM sample uniformly, respectively, was called as heating and cooling process. Hence, thermoelectric had to be supported by a relay control device to change its polarity so it could heat and cool PCM sample alternately and automatically. On the other hand, the thermoelectric was cheap, easy to be found and available in markets. It can be concluded that new method of thermal cycling test by using thermoelectric as source of heating and cooling can be a new reference for performing thermal cycling test on PCM.

  19. A True-False Test on Methods of Typewriting Instruction.

    Science.gov (United States)

    West, Leonard J.

    1984-01-01

    Presents a true-false test on typewriting instruction to illustrate the effects of educational lag, publishing practices, and deficiencies in preservice and inservice teacher education upon teaching methods. (SK)

  20. Testing methods for antimicrobial activity of TiO2 photocatalyst

    Directory of Open Access Journals (Sweden)

    Markov Siniša L.

    2014-01-01

    Full Text Available In recent years, a lot of commercial TiO2 photocatalyst products have been developed and extensively studied for prospective and safe antimicrobial application in daily life, medicine, laboratories, food and pharmaceutical industry, waste water treatments and in development of new self-cleaning and antimicrobial materials, surfaces and paints. This paper reviews the studies published worldwide on killing microorganisms, methods for testing the antimicrobial activity, light sources and intensities, as well as calculation methods usually used when evaluating the antimicrobial properties of the TiO2-based products. Additionally, some strengths and weaknesses of the available methods for testing the antimicrobial activity of TiO2 photocatalyst products have been pointed out.[Projekat Ministarstva nauke Republike Srbije, br. III45008

  1. Large Scale Leach Test Facility: Development of equipment and methods, and comparison to MCC-1 leach tests

    International Nuclear Information System (INIS)

    Pellarin, D.J.; Bickford, D.F.

    1985-01-01

    This report describes the test equipment and methods, and documents the results of the first large-scale MCC-1 experiments in the Large Scale Leach Test Facility (LSLTF). Two experiments were performed using 1-ft-long samples sectioned from the middle of canister MS-11. The leachant used in the experiments was ultrapure deionized water - an aggressive and well characterized leachant providing high sensitivity for liquid sample analyses. All the original test plan objectives have been successfully met. Equipment and procedures have been developed for large-sample-size leach testing. The statistical reliability of the method has been determined, and ''bench mark'' data developed to relate small scale leach testing to full size waste forms. The facility is unique, and provides sampling reliability and flexibility not possible in smaller laboratory scale tests. Future use of this facility should simplify and accelerate the development of leaching models and repository specific data. The factor of less than 3 for leachability, corresponding to a 200,000/1 increase in sample volume, enhances the credibility of small scale test data which precedes this work, and supports the ability of the DWPF waste form to meet repository criteria

  2. Note: An online testing method for lifetime projection of high power light-emitting diode under accelerated reliability test.

    Science.gov (United States)

    Chen, Qi; Chen, Quan; Luo, Xiaobing

    2014-09-01

    In recent years, due to the fast development of high power light-emitting diode (LED), its lifetime prediction and assessment have become a crucial issue. Although the in situ measurement has been widely used for reliability testing in laser diode community, it has not been applied commonly in LED community. In this paper, an online testing method for LED life projection under accelerated reliability test was proposed and the prototype was built. The optical parametric data were collected. The systematic error and the measuring uncertainty were calculated to be within 0.2% and within 2%, respectively. With this online testing method, experimental data can be acquired continuously and sufficient amount of data can be gathered. Thus, the projection fitting accuracy can be improved (r(2) = 0.954) and testing duration can be shortened.

  3. The new null testing method for the special optical window

    Science.gov (United States)

    Huang, Changchun

    2009-07-01

    The high speed, high precision and wide range specifications are requirement for the modern aircraft, which the traditional hemispherical dome can't achieve now, and the novel conformal window instead can enhance the aerodynamic performance of the aircraft obviously. To reduce the aerodynamic drag and radar cross-section, the window geometry is generally aspheric in shape. As a result, the involved fabrication and testing processes are much more challenging than that of conventional optics and must be mastered before these windows and systems can be implemented at an acceptable cost and risk. Metrology is one of the critical areas required to advance the conformal window technology. But as the surface of these conformal windows is not the traditional sphere lens, the measurement method for it is infeasible with the conventional optics measurement processes. This paper we express the development of testing technology for the special conformal windows in brief, and emphatically introduces one available novel testing method- a new null testing, and here based on the theory of compensation methods, The principle of Offner's refractive null lens has been extended to test the transmission wavefront through conformal window optics and provide feedback during surface fabrication. a compensator system for the was designed for the conformal window is given which parameters are 100mm for its aperture and two parabolic surface as conformal window, the final residual wavefront error(RMS) of which is less than 1/20λ(λ=632.8nm).

  4. Standard Test Method for Normal Spectral Emittance at Elevated Temperatures of Nonconducting Specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1971-01-01

    1.1 This test method describes an accurate technique for measuring the normal spectral emittance of electrically nonconducting materials in the temperature range from 1000 to 1800 K, and at wavelengths from 1 to 35 μm. It is particularly suitable for measuring the normal spectral emittance of materials such as ceramic oxides, which have relatively low thermal conductivity and are translucent to appreciable depths (several millimetres) below the surface, but which become essentially opaque at thicknesses of 10 mm or less. 1.2 This test method requires expensive equipment and rather elaborate precautions, but produces data that are accurate to within a few percent. It is particularly suitable for research laboratories, where the highest precision and accuracy are desired, and is not recommended for routine production or acceptance testing. Because of its high accuracy, this test method may be used as a reference method to be applied to production and acceptance testing in case of dispute. 1.3 This test metho...

  5. 78 FR 68076 - Request for Information on Alternative Skin Sensitization Test Methods and Testing Strategies and...

    Science.gov (United States)

    2013-11-13

    ... Laboratory for Alternatives to Animal Testing (EURL ECVAM), and by the industry organization Cosmetics Europe... products. Pesticides and other marketed chemicals, including cosmetic ingredients, are routinely tested for... sensitization. NICEATM collaboration with industry scientists to develop an open-source Bayesian network as an...

  6. Strategies for Solving Potential Problems Associated with Laboratory Diffusion and Batch Experiments - Part 1: An Overview of Conventional Test Methods

    International Nuclear Information System (INIS)

    Zhang, M.; Takeda, M.; Nakajima, H.

    2006-01-01

    Laboratory diffusion testing as well as batch experiments are well established and widely adopted techniques for characterizing the diffusive and adsorptive properties of geological, geotechnical, and synthetic materials in both scientific and applied fields, including geological disposal of radioactive waste. Although several types of diffusion test, such as the through- diffusion test, in-diffusion test, out-diffusion test, and column test, are currently available, different methods may have different advantages and disadvantages. In addition, traditional methods may have limitations, such as the need for relatively long test times, cumbersome test procedures, and the possibility of errors due to differences between analytical assumptions and actual test conditions. Furthermore, traditional batch experiments using mineral powders are known to overestimate the sorption coefficient. In part 1 of this report, we present a brief overview of laboratory diffusion and batch experiments. The advantages, disadvantages, limitations, and/or potential problems associated with individual tests were compared and summarized. This comprehensive report will provide practical references for reviewing the results obtained from relevant experiments, especially from the viewpoint of regulation. To solve and/or eliminate the potential problems associated with conventional methods, and to obtain the diffusion coefficient and rock capacity factor from a laboratory test both rapidly and accurately, part 2 of this study discusses possible strategies involving the development of rigorous solutions to some relevant test methods, and sensitivity analyses for the related tests that may be helpful to judge the accuracy of the two parameters to be determined from individual tests. (authors)

  7. Sensitivity analysis methods and a biosphere test case implemented in EIKOS

    Energy Technology Data Exchange (ETDEWEB)

    Ekstroem, P.A.; Broed, R. [Facilia AB, Stockholm, (Sweden)

    2006-05-15

    Computer-based models can be used to approximate real life processes. These models are usually based on mathematical equations, which are dependent on several variables. The predictive capability of models is therefore limited by the uncertainty in the value of these. Sensitivity analysis is used to apportion the relative importance each uncertain input parameter has on the output variation. Sensitivity analysis is therefore an essential tool in simulation modelling and for performing risk assessments. Simple sensitivity analysis techniques based on fitting the output to a linear equation are often used, for example correlation or linear regression coefficients. These methods work well for linear models, but for non-linear models their sensitivity estimations are not accurate. Usually models of complex natural systems are non-linear. Within the scope of this work, various sensitivity analysis methods, which can cope with linear, non-linear, as well as non-monotone problems, have been implemented, in a software package, EIKOS, written in Matlab language. The following sensitivity analysis methods are supported by EIKOS: Pearson product moment correlation coefficient (CC), Spearman Rank Correlation Coefficient (RCC), Partial (Rank) Correlation Coefficients (PCC), Standardized (Rank) Regression Coefficients (SRC), Sobol' method, Jansen's alternative, Extended Fourier Amplitude Sensitivity Test (EFAST) as well as the classical FAST method and the Smirnov and the Cramer-von Mises tests. A graphical user interface has also been developed, from which the user easily can load or call the model and perform a sensitivity analysis as well as uncertainty analysis. The implemented sensitivity analysis methods has been benchmarked with well-known test functions and compared with other sensitivity analysis software, with successful results. An illustration of the applicability of EIKOS is added to the report. The test case used is a landscape model consisting of several

  8. Sensitivity analysis methods and a biosphere test case implemented in EIKOS

    International Nuclear Information System (INIS)

    Ekstroem, P.A.; Broed, R.

    2006-05-01

    Computer-based models can be used to approximate real life processes. These models are usually based on mathematical equations, which are dependent on several variables. The predictive capability of models is therefore limited by the uncertainty in the value of these. Sensitivity analysis is used to apportion the relative importance each uncertain input parameter has on the output variation. Sensitivity analysis is therefore an essential tool in simulation modelling and for performing risk assessments. Simple sensitivity analysis techniques based on fitting the output to a linear equation are often used, for example correlation or linear regression coefficients. These methods work well for linear models, but for non-linear models their sensitivity estimations are not accurate. Usually models of complex natural systems are non-linear. Within the scope of this work, various sensitivity analysis methods, which can cope with linear, non-linear, as well as non-monotone problems, have been implemented, in a software package, EIKOS, written in Matlab language. The following sensitivity analysis methods are supported by EIKOS: Pearson product moment correlation coefficient (CC), Spearman Rank Correlation Coefficient (RCC), Partial (Rank) Correlation Coefficients (PCC), Standardized (Rank) Regression Coefficients (SRC), Sobol' method, Jansen's alternative, Extended Fourier Amplitude Sensitivity Test (EFAST) as well as the classical FAST method and the Smirnov and the Cramer-von Mises tests. A graphical user interface has also been developed, from which the user easily can load or call the model and perform a sensitivity analysis as well as uncertainty analysis. The implemented sensitivity analysis methods has been benchmarked with well-known test functions and compared with other sensitivity analysis software, with successful results. An illustration of the applicability of EIKOS is added to the report. The test case used is a landscape model consisting of several linked

  9. Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Titanium

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers procedures for measuring reaction rates by the activation reactions 46Ti(n,p) 46Sc + 47Ti(n, np)46Sc. Note 1—Since the cross section for the (n,np) reaction is relatively small for energies less than 12 MeV and is not easily distinguished from that of the (n,p) reaction, this test method will refer to the (n,p) reaction only. 1.2 The reaction is useful for measuring neutrons with energies above approximately 4.4 MeV and for irradiation times up to about 250 days (for longer irradiations, see Practice E 261). 1.3 With suitable techniques, fission-neutron fluence rates above 109 cm–2·s–1 can be determined. However, in the presence of a high thermal-neutron fluence rate, 46Sc depletion should be investigated. 1.4 Detailed procedures for other fast-neutron detectors are referenced in Practice E 261. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all...

  10. The microculture tetrazolium assay (MTA): another colorimetric method of testing Plasmodium falciparum chemosensitivity.

    Science.gov (United States)

    Delhaes, L; Lazaro, J E; Gay, F; Thellier, M; Danis, M

    1999-01-01

    Malarial lactate dehydrogenase (LDH), which uses 3-acetyl pyridine adenine dinucleotide as coenzyme in a reaction leading to the formation of pyruvate from L-lactate, may be used to study the susceptibility of Plasmodium falciparum to a drug in vitro. Several methods to determine the activity of this enzyme are available. One, the colorimetric method of Makler and colleagues, was modified slightly, by using sodium-2,3-bis-[2-methoxy-4-nitro-5-sulphophenyl]-2H-tetrazolium-5 - carboxanilide (XTT) and following the reaction by measuring the optical density at 450 nm. Using two, culture-adapted strains of P. falciparum, this LDH assay was compared with the unmodified Makler's assay and with the isotopic microtest based on the incorporation of tritium-labelled hypoxanthine. Fresh, clinical P. falciparum isolates were also tested in the presence of several drugs, including chloroquine, mefloquine, quinine, halofantrine, atovaquone and qinghaosu derivatives. The results of the three assays were correlated for all the drugs tested except atovaquone. The two enzymatic assays are non-radioactive, rapid, reliable, inexpensive to perform and semi-automatic. However, they do require an initial parasitaemia of 2% with a haematocrit of 1.8%.

  11. Standard Test Method for Gravimetric Determination of Nonvolatile Residue from Cleanroom Gloves

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of solvent extractable nonvolatile residue (NVR) from gloves used in cleanrooms where spacecraft are assembled, cleaned, or tested. 1.2 The NVR of interest is that which can be extracted from gloves using a specified solvent that has been selected for its extracting qualities, or because it is representative of solvents used in the particular facility. Alternative solvents may be used, but since their use may result in different values being generated, they must be identified in the procedure data sheet. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  12. Standard Test Method for Gravimetric Determination of Nonvolatile Residue From Cleanroom Wipers

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method covers the determination of solvent extractable nonvolatile residue (NVR) from wipers used in assembly, cleaning, or testing of spacecraft, but not from those used for analytical surface sampling of hardware. 1.2 The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard. 1.3 The NVR of interest is that which can be extracted from cleanroom wipers using a specified solvent that has been selected for its extractive qualities. Alternative solvents may be selected, but since their use may result in different values being generated, they must be identified in the procedure data sheet. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  13. Field and laboratory test methods for geomembranes during waste management facility construction

    International Nuclear Information System (INIS)

    Allen, S.R.; McCutchan, J.B.

    1991-01-01

    Hazardous waste management facilities are required to use approved lining and leak detection systems to prevent the migration of waste into the environment. Synthetic flexible membrane liners (FMLs) have effectively served as the critical barrier for waste containment and fluid migration. The U.S. EPA has established minimum technology requirements for the construction of lined facilities that include detailed and documented Construction Quality Assurance (CQA) plans. The U.S. EPA (EPA) recognizes that CQA during field construction is imperative for successful completion of project work and long-term facility operation. This paper discusses the importance of CQA during FML installation and the practical aspects of implementing a successful CQA program. Standard methods used for FML evaluation, in both the field and laboratory, are discussed and specific aspects of seam testing and data evaluation are addressed. The general importance of comprehensive definition of geomembrane seam field failures is strongly emphasized so that an appropriate response to test failures can be recommended

  14. Relative Merits of Four Methods for Scoring Cloze Tests.

    Science.gov (United States)

    Brown, James Dean

    1980-01-01

    Describes study comparing merits of exact answer, acceptable answer, clozentropy and multiple choice methods for scoring tests. Results show differences among reliability, mean item facility, discrimination and usability, but not validity. (BK)

  15. Entropy Based Test Point Evaluation and Selection Method for Analog Circuit Fault Diagnosis

    Directory of Open Access Journals (Sweden)

    Yuan Gao

    2014-01-01

    Full Text Available By simplifying tolerance problem and treating faulty voltages on different test points as independent variables, integer-coded table technique is proposed to simplify the test point selection process. Usually, simplifying tolerance problem may induce a wrong solution while the independence assumption will result in over conservative result. To address these problems, the tolerance problem is thoroughly considered in this paper, and dependency relationship between different test points is considered at the same time. A heuristic graph search method is proposed to facilitate the test point selection process. First, the information theoretic concept of entropy is used to evaluate the optimality of test point. The entropy is calculated by using the ambiguous sets and faulty voltage distribution, determined by component tolerance. Second, the selected optimal test point is used to expand current graph node by using dependence relationship between the test point and graph node. Simulated results indicate that the proposed method more accurately finds the optimal set of test points than other methods; therefore, it is a good solution to minimize the size of the test point set. To simplify and clarify the proposed method, only catastrophic and some specific parametric faults are discussed in this paper.

  16. The virtual fields method applied to spalling tests on concrete

    Directory of Open Access Journals (Sweden)

    Forquin P.

    2012-08-01

    Full Text Available For one decade spalling techniques based on the use of a metallic Hopkinson bar put in contact with a concrete sample have been widely employed to characterize the dynamic tensile strength of concrete at strain-rates ranging from a few tens to two hundreds of s−1. However, the processing method mainly based on the use of the velocity profile measured on the rear free surface of the sample (Novikov formula remains quite basic and an identification of the whole softening behaviour of the concrete is out of reach. In the present paper a new processing method is proposed based on the use of the Virtual Fields Method (VFM. First, a digital high speed camera is used to record the pictures of a grid glued on the specimen. Next, full-field measurements are used to obtain the axial displacement field at the surface of the specimen. Finally, a specific virtual field has been defined in the VFM equation to use the acceleration map as an alternative ‘load cell’. This method applied to three spalling tests allowed to identify Young’s modulus during the test. It was shown that this modulus is constant during the initial compressive part of the test and decreases in the tensile part when micro-damage exists. It was also shown that in such a simple inertial test, it was possible to reconstruct average axial stress profiles using only the acceleration data. Then, it was possible to construct local stress-strain curves and derive a tensile strength value.

  17. Creating IRT-Based Parallel Test Forms Using the Genetic Algorithm Method

    Science.gov (United States)

    Sun, Koun-Tem; Chen, Yu-Jen; Tsai, Shu-Yen; Cheng, Chien-Fen

    2008-01-01

    In educational measurement, the construction of parallel test forms is often a combinatorial optimization problem that involves the time-consuming selection of items to construct tests having approximately the same test information functions (TIFs) and constraints. This article proposes a novel method, genetic algorithm (GA), to construct parallel…

  18. A novel method for feasibility testing urban sustainable development policies

    Directory of Open Access Journals (Sweden)

    O’Doherty Travis

    2013-01-01

    Full Text Available Policy making to promote more sustainable development is a complex task due in part to the large number of both stakeholders and potential policies. Policy feasibility testing provides a guide to the viability and practicality of policy implementation and forms an important part of an evidence based policy making process. An extensive literature review has identified no standardized approach to feasibility testing. This paper addresses this knowledge gap by describing a novel method using Multi-Criteria Decision Analysis (MCDA for feasibility testing of policies aimed at increasing the sustainability of towns and villages in Ireland. Feasibility results are provided for 40 frequently cited policy interventions tested for 18 settlements in Ireland. Policies were selected in the arenas of transport, food, housing and urban form, energy, waste and water. Policies are feasibility tested through analysis of operational evidence from both quantitative and qualitative data sources. Following testing, policies are ranked in terms of feasibility. This research examines the effectiveness of local and national level policies and the importance of both local community involvement and central government regulation in policy success. The inter-settlement variation in feasibility testing scores prioritises policy selection and aims to reduce cherry-picking of policies to support the viewpoints of the decision maker. Although developed for an Irish urban context the methods described here may have applicability elsewhere.

  19. Simulation testing the robustness of stock assessment models to error: some results from the ICES strategic initiative on stock assessment methods

    DEFF Research Database (Denmark)

    Deroba, J. J.; Butterworth, D. S.; Methot, R. D.

    2015-01-01

    The World Conference on Stock Assessment Methods (July 2013) included a workshop on testing assessment methods through simulations. The exercise was made up of two steps applied to datasets from 14 representative fish stocks from around the world. Step 1 involved applying stock assessments to dat...

  20. Methods of forming aluminum oxynitride-comprising bodies, including methods of forming a sheet of transparent armor

    Science.gov (United States)

    Chu, Henry Shiu-Hung [Idaho Falls, ID; Lillo, Thomas Martin [Idaho Falls, ID

    2008-12-02

    The invention includes methods of forming an aluminum oxynitride-comprising body. For example, a mixture is formed which comprises A:B:C in a respective molar ratio in the range of 9:3.6-6.2:0.1-1.1, where "A" is Al.sub.2O.sub.3, "B" is AlN, and "C" is a total of one or more of B.sub.2O.sub.3, SiO.sub.2, Si--Al--O--N, and TiO.sub.2. The mixture is sintered at a temperature of at least 1,600.degree. C. at a pressure of no greater than 500 psia effective to form an aluminum oxynitride-comprising body which is at least internally transparent and has at least 99% maximum theoretical density.

  1. Path-Wise Test Data Generation Based on Heuristic Look-Ahead Methods

    Directory of Open Access Journals (Sweden)

    Ying Xing

    2014-01-01

    Full Text Available Path-wise test data generation is generally considered an important problem in the automation of software testing. In essence, it is a constraint optimization problem, which is often solved by search methods such as backtracking algorithms. In this paper, the backtracking algorithm branch and bound and state space search in artificial intelligence are introduced to tackle the problem of path-wise test data generation. The former is utilized to explore the space of potential solutions and the latter is adopted to construct the search tree dynamically. Heuristics are employed in the look-ahead stage of the search. Dynamic variable ordering is presented with a heuristic rule to break ties, values of a variable are determined by the monotonicity analysis on branching conditions, and maintaining path consistency is achieved through analysis on the result of interval arithmetic. An optimization method is also proposed to reduce the search space. The results of empirical experiments show that the search is conducted in a basically backtrack-free manner, which ensures both test data generation with promising performance and its excellence over some currently existing static and dynamic methods in terms of coverage. The results also demonstrate that the proposed method is applicable in engineering.

  2. Method for screening the Nevada Test Site and contiguous areas for nuclear waste repository locations

    International Nuclear Information System (INIS)

    Sinnock, S.; Fernandez, J.A.; Neal, J.T.; Stephens, H.P.; Hartway, B.L.; Los Alamos Technical Associates, Inc., NM)

    1982-01-01

    This paper outlines the general concepts of a technical method for systematic screening of the Nevada Test Site (NTS), Nye County, Nevada, for potentially suitable nuclear waste repository locations. After a general discussion of the organization and the purpose of the current screening activity, the paper addresses the steps of the screening method. These steps include: hierarchically organizing technical objectives for repository performance (an objectives tree); identifying and mapping pertinent physical characteristics of a site and its setting (physical attributes); relating the physical conditions to the objectives (favorability curves); identifying alternative locations and numerically evaluating their relative merits; investigating the effects of subjective judgments on the evaluations (sensitivity analyses); documenting the assumptions, logic, and results of the method. 19 references, 10 figures

  3. Standard Test Methods for Insulation Integrity and Ground Path Continuity of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 These test methods cover procedures for (1) testing for current leakage between the electrical circuit of a photovoltaic module and its external components while a user-specified voltage is applied and (2) for testing for possible module insulation breakdown (dielectric voltage withstand test). 1.2 A procedure is described for measuring the insulation resistance between the electrical circuit of a photovoltaic module and its external components (insulation resistance test). 1.3 A procedure is provided for verifying that electrical continuity exists between the exposed external conductive surfaces of the module, such as the frame, structural members, or edge closures, and its grounding point (ground path continuity test). 1.4 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method. 1.5 There is no similar or equivalent ISO standard. This standard does not purport to address all of the safety concerns, if a...

  4. Standard Test Method for Solar Transmittance (Terrestrial) of Sheet Materials Using Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1986-01-01

    1.1 This test method covers the measurement of solar transmittance (terrestrial) of materials in sheet form by using a pyranometer, an enclosure, and the sun as the energy source. 1.2 This test method also allows measurement of solar transmittance at angles other than normal incidence. 1.3 This test method is applicable to sheet materials that are transparent, translucent, textured, or patterned. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. Engine including hydraulically actuated valvetrain and method of valve overlap control

    Science.gov (United States)

    Cowgill, Joel [White Lake, MI

    2012-05-08

    An exhaust valve control method may include displacing an exhaust valve in communication with the combustion chamber of an engine to an open position using a hydraulic exhaust valve actuation system and returning the exhaust valve to a closed position using the hydraulic exhaust valve actuation assembly. During closing, the exhaust valve may be displaced for a first duration from the open position to an intermediate closing position at a first velocity by operating the hydraulic exhaust valve actuation assembly in a first mode. The exhaust valve may be displaced for a second duration greater than the first duration from the intermediate closing position to a fully closed position at a second velocity at least eighty percent less than the first velocity by operating the hydraulic exhaust valve actuation assembly in a second mode.

  6. Statistical Methods for the detection of answer copying on achievement tests

    NARCIS (Netherlands)

    Sotaridona, Leonardo

    2003-01-01

    This thesis contains a collection of studies where statistical methods for the detection of answer copying on achievement tests in multiple-choice format are proposed and investigated. Although all methods are suited to detect answer copying, each method is designed to address specific

  7. Comparison of a New and Rapid Method: Brucella Coombs Gel Test With Other Diagnostic Tests.

    Science.gov (United States)

    Kalem, Fatma; Ergün, Ayşe Gül; Durmaz, Süleyman; Doğan, Metin; Ertuğrul, Ömür; Gündem, Seval

    2016-09-01

    The aim of this study was to detect reliability of Brucella Coombs gel test (BCGT) by comparing with with ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination methods in serological diagnosis of brucellosis. Brucella Coombs gel test (BCGT), Brucella ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination tests of 78 patients with presumptive diagnosis of brucellosis which were sent to Microbiology Laboratory of Konya Numune Hospital from various regions of Konya were studied. Of 78 patients with ELISA IgG and IgM, STA, BICA and BCGT; 26, 21, 10, 12 and 12 were positive. When compared with BICA, the sensitivity and specifity of BCGT were 100% and 100%, respectively. According to results BCGT can be used as a diagnostic test in routine laboratories after more comprehensive studies in control groups and patients. © 2016 Wiley Periodicals, Inc.

  8. Standard test method for radiochemical determination of plutonium in Soil by alpha spectroscopy

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of plutonium in soils at levels of detection dependent on count time, sample size, detector, background, and tracer yield. This test method describes one acceptable approach to the determination of plutonium in soil. 1.2 This test method is designed for 10 g of soil, previously collected and treated as described in Practices C998 and C999, but sample sizes up to 50 g may be analyzed by this test method. This test method may not be able to completely dissolve all forms of plutonium in the soil matrix. 1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 9.

  9. 40 CFR 63.1365 - Test methods and initial compliance procedures.

    Science.gov (United States)

    2010-07-01

    ... permit limit applicable to the process vent. (D) Design analysis based on accepted chemical engineering... concentration, temperature, and the reaction kinetics of the constituents with the scrubbing liquid. The design... procedures specified in Method 8260 or 8270 in “Test Methods for Evaluating Solid Waste, Physical/Chemical...

  10. MCC-15: waste/canister accident testing and analysis method

    International Nuclear Information System (INIS)

    Slate, S.C.; Pulsipher, B.A.; Scott, P.A.

    1985-02-01

    The Materials Characterization Center (MCC) at the Pacific Northwest Laboratory (PNL) is developing standard tests to characterize the performance of nuclear waste forms under normal and accident conditions. As part of this effort, the MCC is developing MCC-15, Waste/Canister Accident Testing and Analysis. MCC-15 is used to test canisters containing simulated waste forms to provide data on the effects of accidental impacts on the waste form particle size and on canister integrity. The data is used to support the design of transportation and handling equipment and to demonstrate compliance with repository waste acceptance specifications. This paper reviews the requirements that led to the development of MCC-15, describes the test method itself, and presents some early results from tests on canisters representative of those proposed for the Defense Waste Processing Facility (DWPF). 13 references, 6 figures

  11. Apparatus and method for defect testing of integrated circuits

    Science.gov (United States)

    Cole, Jr., Edward I.; Soden, Jerry M.

    2000-01-01

    An apparatus and method for defect and failure-mechanism testing of integrated circuits (ICs) is disclosed. The apparatus provides an operating voltage, V.sub.DD, to an IC under test and measures a transient voltage component, V.sub.DDT, signal that is produced in response to switching transients that occur as test vectors are provided as inputs to the IC. The amplitude or time delay of the V.sub.DDT signal can be used to distinguish between defective and defect-free (i.e. known good) ICs. The V.sub.DDT signal is measured with a transient digitizer, a digital oscilloscope, or with an IC tester that is also used to input the test vectors to the IC. The present invention has applications for IC process development, for the testing of ICs during manufacture, and for qualifying ICs for reliability.

  12. Rock mechanics methods and in situ heater tests for design of a nuclear waste repository in basalt

    International Nuclear Information System (INIS)

    Board, M.P.

    1978-01-01

    Methods of integrating data from the Near-Surface Test Facility into the overall Waste Isolation Program are examined. Discussions are presented dealing primarily with the application of numerical models to the design of a waste repository. The various types of models currently available are discussed with reference to design in basalt and the breakdown of the problem of repository design is summarized. It is shown that the most efficient method for analyzing repository design is to break the problem down into several problems which are based on physical scale. These include the area directly surrounding a single waste canister (the very near field), the area including many canisters and canister emplacement rooms (the near field), and the area including the entire repository and the rock mass to the free surface (the far field). The methods by which numerical models are used for design are discussed. Flow charts are used to show the basic input data required, the calculational processes used, and the preliminary criteria for judgment of suitable repository performance. It is shown that the ultimate design of the allowable gross thermal loading density, and, thus, the layout of the underground workings is highly dependent upon the rock mass properties supplied as base line input data to the numerical models. Of the many input properties required, the thermal conductivity, the thermal expansion coefficient, and elastic moduli of the rock mass have, perhaps, the greatest effect on the calculation of induced temperatures, stresses, and displacements and, thus, repository design. To ensure that the design continues with confidence, field (in situ) values of input data must be obtained. The role of the Near-Surface Test Facility in situ testing in obtaining these basic required data is discussed

  13. Underground Nuclear Testing Program, Nevada Test Site

    International Nuclear Information System (INIS)

    1975-09-01

    The Energy Research and Development Administration (ERDA) continues to conduct an underground nuclear testing program which includes tests for nuclear weapons development and other tests for development of nuclear explosives and methods for their application for peaceful uses. ERDA also continues to provide nuclear explosive and test site support for nuclear effects tests sponsored by the Department of Defense. This Supplement extends the Environmental Statement (WASH-1526) to cover all underground nuclear tests and preparations for tests of one megaton (1 MT) or less at the Nevada Test Site (NTS) during Fiscal Year 1976. The test activities covered include numerous continuing programs, both nuclear and non-nuclear, which can best be conducted in a remote area. However, if nuclear excavation tests or tests of yields above 1 MT or tests away from NTS should be planned, these will be covered by separate environmental statements

  14. A probabilistic method for testing and estimating selection differences between populations.

    Science.gov (United States)

    He, Yungang; Wang, Minxian; Huang, Xin; Li, Ran; Xu, Hongyang; Xu, Shuhua; Jin, Li

    2015-12-01

    Human populations around the world encounter various environmental challenges and, consequently, develop genetic adaptations to different selection forces. Identifying the differences in natural selection between populations is critical for understanding the roles of specific genetic variants in evolutionary adaptation. Although numerous methods have been developed to detect genetic loci under recent directional selection, a probabilistic solution for testing and quantifying selection differences between populations is lacking. Here we report the development of a probabilistic method for testing and estimating selection differences between populations. By use of a probabilistic model of genetic drift and selection, we showed that logarithm odds ratios of allele frequencies provide estimates of the differences in selection coefficients between populations. The estimates approximate a normal distribution, and variance can be estimated using genome-wide variants. This allows us to quantify differences in selection coefficients and to determine the confidence intervals of the estimate. Our work also revealed the link between genetic association testing and hypothesis testing of selection differences. It therefore supplies a solution for hypothesis testing of selection differences. This method was applied to a genome-wide data analysis of Han and Tibetan populations. The results confirmed that both the EPAS1 and EGLN1 genes are under statistically different selection in Han and Tibetan populations. We further estimated differences in the selection coefficients for genetic variants involved in melanin formation and determined their confidence intervals between continental population groups. Application of the method to empirical data demonstrated the outstanding capability of this novel approach for testing and quantifying differences in natural selection. © 2015 He et al.; Published by Cold Spring Harbor Laboratory Press.

  15. A Comparison of Multidimensional Item Selection Methods in Simple and Complex Test Designs

    Directory of Open Access Journals (Sweden)

    Eren Halil ÖZBERK

    2017-03-01

    Full Text Available In contrast with the previous studies, this study employed various test designs (simple and complex which allow the evaluation of the overall ability score estimations across multiple real test conditions. In this study, four factors were manipulated, namely the test design, number of items per dimension, correlation between dimensions and item selection methods. Using the generated item and ability parameters, dichotomous item responses were generated in by using M3PL compensatory multidimensional IRT model with specified correlations. MCAT composite ability score accuracy was evaluated using absolute bias (ABSBIAS, correlation and the root mean square error (RMSE between true and estimated ability scores. The results suggest that the multidimensional test structure, number of item per dimension and correlation between dimensions had significant effect on item selection methods for the overall score estimations. For simple structure test design it was found that V1 item selection has the lowest absolute bias estimations for both long and short tests while estimating overall scores. As the model gets complex KL item selection method performed better than other two item selection method.

  16. Harmonisation of microbial sampling and testing methods for distillate fuels

    Energy Technology Data Exchange (ETDEWEB)

    Hill, G.C.; Hill, E.C. [ECHA Microbiology Ltd., Cardiff (United Kingdom)

    1995-05-01

    Increased incidence of microbial infection in distillate fuels has led to a demand for organisations such as the Institute of Petroleum to propose standards for microbiological quality, based on numbers of viable microbial colony forming units. Variations in quality requirements, and in the spoilage significance of contaminating microbes plus a tendency for temporal and spatial changes in the distribution of microbes, makes such standards difficult to implement. The problem is compounded by a diversity in the procedures employed for sampling and testing for microbial contamination and in the interpretation of the data obtained. The following paper reviews these problems and describes the efforts of The Institute of Petroleum Microbiology Fuels Group to address these issues and in particular to bring about harmonisation of sampling and testing methods. The benefits and drawbacks of available test methods, both laboratory based and on-site, are discussed.

  17. Application Study of Self-balanced Testing Method on Big Diameter Rock-socketed Piles

    Directory of Open Access Journals (Sweden)

    Qing-biao WANG

    2013-07-01

    Full Text Available Through the technological test of self-balanced testing method on big diameter rock-socketed piles of broadcasting centre building of Tai’an, this paper studies and analyzes the links of the balance position selection, the load cell production and installation, displacement sensor selection and installation, loading steps, stability conditions and determination of the bearing capacity in the process of self-balanced testing. And this paper summarizes key technology and engineering experience of self-balanced testing method of big diameter rock-socketed piles and, meanwhile, it also analyzes the difficult technical problems needed to be resolved urgently at present. Conclusion of the study has important significance to the popularization and application of self-balanced testing method and the similar projects.

  18. Standard test method for conducting drop-weight test to determine nil-ductility transition temperature of ferritic steels

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method covers the determination of the nil-ductility transition (NDT) temperature of ferritic steels, 5/8 in. (15.9 mm) and thicker. 1.2 This test method may be used whenever the inquiry, contract, order, or specification states that the steels are subject to fracture toughness requirements as determined by the drop-weight test. 1.3 The values stated in inch-pound units are to be regarded as the standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  19. Appropriate statistical methods are required to assess diagnostic tests for replacement, add-on, and triage

    NARCIS (Netherlands)

    Hayen, Andrew; Macaskill, Petra; Irwig, Les; Bossuyt, Patrick

    2010-01-01

    To explain which measures of accuracy and which statistical methods should be used in studies to assess the value of a new binary test as a replacement test, an add-on test, or a triage test. Selection and explanation of statistical methods, illustrated with examples. Statistical methods for

  20. Solubility tests and the peripheral blood film method for screening ...

    African Journals Online (AJOL)

    Objective. To determine the cost benefit of screening for sicklecell disease among infants at district health centres in Uganda using sickling, solubility tests and the peripheral blood film method. Methods. Pilot screening services were established at district health centres. Cost benefit analysis (CBA) was performed in four ...