WorldWideScience

Sample records for methods include conventional

  1. Principles of cobalt-60 teletherapy including an introduction to the compendium. Definitions and conventions

    International Nuclear Information System (INIS)

    Cohen, M.; Mitchell, J.S.

    1984-01-01

    The convention used in the display of the transverse sections of the human body in the plans for radiotherapy follows the editorial policy of the Journal of Computer Assisted Tomography. For the purpose of this Compendium the convention is defined as: The ''seen from above'' convention is used for the head and upper neck, in which is included the oropharynx. This is the 'anatomical convention' now used with the computed tomography (CT) head scanner and is accepted generally by neuroradiologists, neurosurgeons and neurologists. This convention is also employed in the display of isotope scans of the head. The ''seen from below'' convention is used for the rest of the body, i.e. below the level of the lower border of the third cervical vertebral body; this includes the hypopharynx, larynx and thyroid. This is the usual 'radiological convention', i.e. the patient's right is on the observer's left. This is the convention generally used in total body CT scanning of the thorax and abdomen; the same convention is used in isotope and ultrasonic imaging

  2. Issues in identifying germ tube positive yeasts by conventional methods.

    Science.gov (United States)

    Yazdanpanah, Atta; Khaithir, Tzar Mohd Nizam

    2014-01-01

    Candida speciation is vital for epidemiology and management of candidiasis. Nonmolecular conventional methods often fail to identify closely related germ tube positive yeasts from clinical specimens. The present study was conducted to identify these yeasts and to highlight issues in conventional versus molecular methods of identification. A total of 98 germ tube positive yeasts from high vaginal swabs were studied over a 12-month period. Isolates were examined with various methods including growth at 42 °C and 45 °C on Sabouraud dextrose agar (SDA), color development on CHROMagar Candida medium, chlamydospore production on corn meal agar at 25 °C, carbohydrate assimilation using ID 32C system, and polymerase chain reaction using a single pair of primers targeting the hyphal wall protein 1 (Hwp1) gene. Of all the isolates studied, 97 were molecularly confirmed as C. albicans and one isolate was identified as C. dubliniensis. No C. africana was detected in this study. The molecular method used in our study was an accurate and useful tool for discriminating C. albicans, C. dubliniensis, and C. africana. The conventional methods, however, were less accurate and riddled with many issues that will be discussed in further details. © 2013 Wiley Periodicals, Inc.

  3. Fuzzy logic control to be conventional method

    International Nuclear Information System (INIS)

    Eker, Ilyas; Torun, Yunis

    2006-01-01

    Increasing demands for flexibility and fast reactions in modern process operation and production methods result in nonlinear system behaviour of partly unknown systems, and this necessitates application of alternative control methods to meet the demands. Fuzzy logic (FL) control can play an important role because knowledge based design rules can easily be implemented in systems with unknown structure, and it is going to be a conventional control method since the control design strategy is simple and practical and is based on linguistic information. Computational complexity is not a limitation any more because the computing power of computers has been significantly improved even for high speed industrial applications. This makes FL control an important alternative method to the conventional PID control method for use in nonlinear industrial systems. This paper presents a practical implementation of the FL control to an electrical drive system. Such drive systems used in industry are composed of masses moving under the action of position and velocity dependent forces. These forces exhibit nonlinear behaviour. For a multi-mass drive system, the nonlinearities, like Coulomb friction and dead zone, significantly influence the operation of the systems. The proposed FL control configuration is based on speed error and change of speed error. The feasibility and effectiveness of the control method are experimentally demonstrated. The results obtained from conventional FL control, fuzzy PID and adaptive FL control are compared with traditional PID control for the dynamic responses of the closed loop drive system

  4. Fuzzy logic control to be conventional method

    Energy Technology Data Exchange (ETDEWEB)

    Eker, Ilyas [University of Gaziantep, Gaziantep (Turkey). Department of Electrical and Electronic Engineering; Torun, Yunis [University of Gaziantep, Gaziantep (Turkey). Technical Vocational School of Higher Education

    2006-03-01

    Increasing demands for flexibility and fast reactions in modern process operation and production methods result in nonlinear system behaviour of partly unknown systems, and this necessitates application of alternative control methods to meet the demands. Fuzzy logic (FL) control can play an important role because knowledge based design rules can easily be implemented in systems with unknown structure, and it is going to be a conventional control method since the control design strategy is simple and practical and is based on linguistic information. Computational complexity is not a limitation any more because the computing power of computers has been significantly improved even for high speed industrial applications. This makes FL control an important alternative method to the conventional PID control method for use in nonlinear industrial systems. This paper presents a practical implementation of the FL control to an electrical drive system. Such drive systems used in industry are composed of masses moving under the action of position and velocity dependent forces. These forces exhibit nonlinear behaviour. For a multi-mass drive system, the nonlinearities, like Coulomb friction and dead zone, significantly influence the operation of the systems. The proposed FL control configuration is based on speed error and change of speed error. The feasibility and effectiveness of the control method are experimentally demonstrated. The results obtained from conventional FL control, fuzzy PID and adaptive FL control are compared with traditional PID control for the dynamic responses of the closed loop drive system. (author)

  5. The clinical significance of computerized axial tomography (CAT) in consideration of conventional diagnostic methods

    International Nuclear Information System (INIS)

    Huenig, R.

    1976-01-01

    Regarding CAT of the intracranial region, the article informs on a) techniques of examination including the production of normal structures, b) the recognizable pathological changes, c) possibilities of enhancement, d) possibilities of course observation, e) limitations of the methods, as well as on f) risk/benefit aspects g) benefit/cost calculations as compared to conventional methods, and on h) the influence of CAT on the frequency of conventional methods of examination. Regarding CAT of the extracranial region, the information available up to the meeting is reported on. (orig./LH) [de

  6. Strategy for identification & characterization of Bartonella henselae with conventional & molecular methods

    Directory of Open Access Journals (Sweden)

    Kavita Diddi

    2013-01-01

    Full Text Available Background & objectives: Bartonella henselae is a fastidious gram-negative bacterium usually causing self limiting infections in immunocompetent individuals but often causes potentially life threatening infection, such as bacillary angiomatosis in immunocompromised patients. Both diagnosis of infections and research into molecular mechanisms of pathogenesis have been hindered by lack of appropriate and reliable diagnostic techniques. We undertook this study to standardize methods to characterize B. henselae in clinical samples to diagnose Bartonella infection correctly. Methods: B. henselae ATCC 49882 strain was procured from American type culture collection, USA. This strain was revived and maintained in the laboratory, and identification and characterization of this strain was done by conventional and molecular techniques, which included culture on various media, staining by different methods including electron microscopy, biochemical analysis by conventional methods and API, polymerase chain reaction (PCR for amplification of citrate synthase gene followed by restriction fragment length polymorphism (RFLP. Results: This organism was biochemically inert due to slow growth and generated unique identification code with API. The amplification of the citrate-synthase gene with primers yielded a 381 bp product followed by specific RFLP profile for B. henselae. Interpretation & conclusions: Bartonella is fastidious and fragile organism and should be handled carefully. Extra effort and careful observation are required to isolate and characterize this organism.

  7. The comparative evaluation of patients′ body dry weight under hemodialysis using two methods: Bioelectrical impedance analysis and conventional method

    Directory of Open Access Journals (Sweden)

    Neda Alijanian

    2012-01-01

    Full Text Available Background: Dry weight (DW is an important concept related to patients undergoing hemodialysis. Conventional method seems to be time consuming and operator dependent. Bio impedance analysis (BIA is a new and simple method reported to be an accurate way for estimating DW. In this study, we aimed to compare the conventional estimation of DW with measuring DW by BIA. Materials and Methods: This study involved 130 uremic patients, performed in Isfahan, Iran. DW was calculated by both conventional (CDW and BIA (BIADW method and results were compared based on different grouping factors including sex, underlying cause of renal failure (RF (diabetic RF and non-diabetic RF, body mass index (BMI status, and sessions of hemodialysis. We also calculated the difference between DWs of 2 methods (DW diff = CDW-BIADW. Results: The mean of BIADW was significantly lower than CDW (57.20 ± 1.82 vs 59.36 ± 1.77, P value < 0.001. After grouping cases according to the underlying cause, BMI, sex, and dialysis sessions BIADW was significantly lower than CDW. Conclusion: Based on the combination of problems with CDW measurement which are corrected by BIA, and more clinical reliability of CDW, we concluded that although conventional method is a time-consuming and operator-dependent way to assess DW, DW could be estimated by combining both of these methods by finding the mathematic correlation between these methods.

  8. Interphase Chromosome Profiling: A Method for Conventional Banded Chromosome Analysis Using Interphase Nuclei.

    Science.gov (United States)

    Babu, Ramesh; Van Dyke, Daniel L; Dev, Vaithilingam G; Koduru, Prasad; Rao, Nagesh; Mitter, Navnit S; Liu, Mingya; Fuentes, Ernesto; Fuentes, Sarah; Papa, Stephen

    2018-02-01

    - Chromosome analysis on bone marrow or peripheral blood samples fails in a small proportion of attempts. A method that is more reliable, with similar or better resolution, would be a welcome addition to the armamentarium of the cytogenetics laboratory. - To develop a method similar to banded metaphase chromosome analysis that relies only on interphase nuclei. - To label multiple targets in an equidistant fashion along the entire length of each chromosome, including landmark subtelomere and centromere regions. Each label so generated by using cloned bacterial artificial chromosome probes is molecularly distinct with unique spectral characteristics, so the number and position of the labels can be tracked to identify chromosome abnormalities. - Interphase chromosome profiling (ICP) demonstrated results similar to conventional chromosome analysis and fluorescence in situ hybridization in 55 previously studied cases and obtained useful ICP chromosome analysis results on another 29 cases in which conventional methods failed. - ICP is a new and powerful method to karyotype peripheral blood and bone marrow aspirate preparations without reliance on metaphase chromosome preparations. It will be of particular value for cases with a failed conventional analysis or when a fast turnaround time is required.

  9. Energy indices in irrigated wheat production under conservation and conventional tillage and planting methods

    Directory of Open Access Journals (Sweden)

    S. M Hosseini

    2016-04-01

    Full Text Available Introduction: Conservation tillage system was recommended for soil erosion control in North America for the first time 60 years ago (Wang et al., 2006. Using this tillage system including minimum and zero tillage has been rapidly developed in recent years. Thearea covered by zero tillage in 2006 was 95 million ha all over the world (Dumanski et al., 2006. In addition to saving soil and water resources, conservation tillage system reduces energy consumption and improves energy indices by combining different tillage and planting operations. Results of research conducted in Fars province shows that conservation tillage saves fuel consumption for 77% compared to the conventional system (Afzalinia et al., 2009. Conservation tillage also reduces energy consumption from 23.6 to 42.8% in comparison to the conventional tillage (Rusu, 2005. Since energy indices would be affected by reduced input energies in conservation tillage, this research was conducted to evaluate the effect of different tillage and planting methods on energy inputs and energy indices in irrigated wheat production in Eghlid region. Materials and Methods: This research was performed to evaluate and compare the energy indices in irrigated wheat production under different tillage and planting methods. The study was conducted in the form of a randomized complete block experimental design with five treatments and three replications in Eghlid region. The treatments were included, conventional tillage and seed broadcasting (A, conventional tillage and planting with Machine Barzegar grain drill (B, reduced tillage and seeding with Roto-seeder (C, direct seeding with Jairan Sanaat grain drill (D, and direct seeding with Sfoggia direct drill (E. Experimental plots with 10 by 50 m dimensions were used in this study. Loss crop residues were taken out of the experimental plots and standing crop residues were retained in the plots. In the conventional tillage method, primary tillage was performed

  10. Non-conventional energy and propulsion methods

    International Nuclear Information System (INIS)

    Valone, T.

    1991-01-01

    From the disaster of the Space Shuttle, Challenger, to the Kuwaiti oil well fires, we are reminded constantly of our dependence on dangerous, combustible fuels for energy and propulsion. Over the past ten years, there has been a considerable production of new and exciting inventions which defy conventional analysis. The term non-conventional was coined in 1980 by a Canadian engineer to designate a separate technical discipline for this type of endeavor. Since then, several conferences have been devoted solely to these inventions. Integrity Research Corp., an affiliate of the Institute, has made an effort to investigate each viable product, develop business plans for several to facilitate development and marketing, and in some cases, assign an engineering student intern to building a working prototype. Each inventor discussed in this presentation has produced a unique device for free energy generation or highly efficient force production. Included in this paper is also a short summary for non-specialists explaining the physics of free energy generation along with a working definition. The main topics of discussion include: space power, inertial propulsion, kinetobaric force, magnetic motors, thermal fluctuations, over-unity hat pumps, ambient temperature superconductivity and nuclear battery

  11. Comparative study of the geostatistical ore reserve estimation method over the conventional methods

    International Nuclear Information System (INIS)

    Kim, Y.C.; Knudsen, H.P.

    1975-01-01

    Part I contains a comprehensive treatment of the comparative study of the geostatistical ore reserve estimation method over the conventional methods. The conventional methods chosen for comparison were: (a) the polygon method, (b) the inverse of the distance squared method, and (c) a method similar to (b) but allowing different weights in different directions. Briefly, the overall result from this comparative study is in favor of the use of geostatistics in most cases because the method has lived up to its theoretical claims. A good exposition on the theory of geostatistics, the adopted study procedures, conclusions and recommended future research are given in Part I. Part II of this report contains the results of the second and the third study objectives, which are to assess the potential benefits that can be derived by the introduction of the geostatistical method to the current state-of-the-art in uranium reserve estimation method and to be instrumental in generating the acceptance of the new method by practitioners through illustrative examples, assuming its superiority and practicality. These are given in the form of illustrative examples on the use of geostatistics and the accompanying computer program user's guide

  12. Review of conventional and novel food processing methods on food allergens.

    Science.gov (United States)

    Vanga, Sai Kranthi; Singh, Ashutosh; Raghavan, Vijaya

    2017-07-03

    With the turn of this century, novel food processing techniques have become commercially very important because of their profound advantages over the traditional methods. These novel processing methods tend to preserve the characteristic properties of food including their organoleptic and nutritional qualities better when compared with the conventional food processing methods. During the same period of time, there is a clear rise in the populations suffering from food allergies, especially infants and children. Though, this fact is widely attributed to the changing livelihood of population in both developed and developing nations and to the introduction of new food habits with advent of novel foods and new processing techniques, their complete role is still uncertain. Under the circumstance, it is very important to understand the structural changes in the protein as food is processed to comprehend whether the specific processing technique (conventional and novel) is increasing or mitigating the allergenicity. Various modern means are now being employed to understand the conformational changes in the protein which can affect the allergenicity. In this review, the processing effects on protein structure and allergenicity are discussed along with the insinuations of recent studies and techniques for establishing a platform to investigate future pathway to reduce or eliminate allergenicity in the population.

  13. Investigation of Industrialised Building System Performance in Comparison to Conventional Construction Method

    Directory of Open Access Journals (Sweden)

    Othuman Mydin M.A.

    2014-03-01

    Full Text Available Conventional construction methods are still widely practised, although many researches have indicated that this method is less effective compared to the IBS construction method. The existence of the IBS has added to the many techniques within the construction industry. This study is aimed at making comparisons between the two construction approaches. Case studies were conducted at four sites in the state of Penang, Malaysia. Two projects were IBS-based while the remaining two deployed the conventional method of construction. Based on an analysis of the results, it can be concluded that the IBS approach has more to offer compared to the conventional method. Among these advantages are shorter construction periods, reduced overall costs, less labour needs, better site conditions and the production of higher quality components.

  14. Comparison of Different Recruitment Methods for Sexual and Reproductive Health Research: Social Media-Based Versus Conventional Methods.

    Science.gov (United States)

    Motoki, Yoko; Miyagi, Etsuko; Taguri, Masataka; Asai-Sato, Mikiko; Enomoto, Takayuki; Wark, John Dennis; Garland, Suzanne Marie

    2017-03-10

    Prior research about the sexual and reproductive health of young women has relied mostly on self-reported survey studies. Thus, participant recruitment using Web-based methods can improve sexual and reproductive health research about cervical cancer prevention. In our prior study, we reported that Facebook is a promising way to reach young women for sexual and reproductive health research. However, it remains unknown whether Web-based or other conventional recruitment methods (ie, face-to-face or flyer distribution) yield comparable survey responses from similar participants. We conducted a survey to determine whether there was a difference in the sexual and reproductive health survey responses of young Japanese women based on recruitment methods: social media-based and conventional methods. From July 2012 to March 2013 (9 months), we invited women of ages 16-35 years in Kanagawa, Japan, to complete a Web-based questionnaire. They were recruited through either a social media-based (social networking site, SNS, group) or by conventional methods (conventional group). All participants enrolled were required to fill out and submit their responses through a Web-based questionnaire about their sexual and reproductive health for cervical cancer prevention. Of the 243 participants, 52.3% (127/243) were recruited by SNS, whereas 47.7% (116/243) were recruited by conventional methods. We found no differences between recruitment methods in responses to behaviors and attitudes to sexual and reproductive health survey, although more participants from the conventional group (15%, 14/95) chose not to answer the age of first intercourse compared with those from the SNS group (5.2%, 6/116; P=.03). No differences were found between recruitment methods in the responses of young Japanese women to a Web-based sexual and reproductive health survey. ©Yoko Motoki, Etsuko Miyagi, Masataka Taguri, Mikiko Asai-Sato, Takayuki Enomoto, John Dennis Wark, Suzanne Marie Garland. Originally

  15. Effect of conventional cooking methods on lipid oxidation indices in lamb meat

    OpenAIRE

    A Pourkhalili; M Mirlohi; E Rahimi; M Hojatoleslami

    2012-01-01

    Lipid oxidation is one of the most deteriorative reactions occurred in foodstuff which has harmful impacts on the both food quality and consumer's health. This study was designed to speculate the influence of three conventional cooking methods including boiling, frying and grilling on lipid oxidation parameters in cooked lamb meat. Sections of lamb meat from longissimus dorsi muscle, taken from native Lori-Bakhtiary sheep species were cut into uniform pieces and cooked using boiling, frying a...

  16. SU-F-J-86: Method to Include Tissue Dose Response Effect in Deformable Image Registration

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, J; Liang, J; Chen, S; Qin, A; Yan, D [Beaumont Health Systeml, Royal Oak, MI (United States)

    2016-06-15

    Purpose: Organ changes shape and size during radiation treatment due to both mechanical stress and radiation dose response. However, the dose response induced deformation has not been considered in conventional deformable image registration (DIR). A novel DIR approach is proposed to include both tissue elasticity and radiation dose induced organ deformation. Methods: Assuming that organ sub-volume shrinkage was proportional to the radiation dose induced cell killing/absorption, the dose induced organ volume change was simulated applying virtual temperature on each sub-volume. Hence, both stress and heterogeneity temperature induced organ deformation. Thermal stress finite element method with organ surface boundary condition was used to solve deformation. Initial boundary correspondence on organ surface was created from conventional DIR. Boundary condition was updated by an iterative optimization scheme to minimize elastic deformation energy. The registration was validated on a numerical phantom. Treatment dose was constructed applying both the conventional DIR and the proposed method using daily CBCT image obtained from HN treatment. Results: Phantom study showed 2.7% maximal discrepancy with respect to the actual displacement. Compared with conventional DIR, subvolume displacement difference in a right parotid had the mean±SD (Min, Max) to be 1.1±0.9(−0.4∼4.8), −0.1±0.9(−2.9∼2.4) and −0.1±0.9(−3.4∼1.9)mm in RL/PA/SI directions respectively. Mean parotid dose and V30 constructed including the dose response induced shrinkage were 6.3% and 12.0% higher than those from the conventional DIR. Conclusion: Heterogeneous dose distribution in normal organ causes non-uniform sub-volume shrinkage. Sub-volume in high dose region has a larger shrinkage than the one in low dose region, therefore causing more sub-volumes to move into the high dose area during the treatment course. This leads to an unfavorable dose-volume relationship for the normal organ

  17. Conservation Farming and Changing Climate: More Beneficial than Conventional Methods for Degraded Ugandan Soils

    Directory of Open Access Journals (Sweden)

    Drake N. Mubiru

    2017-06-01

    Full Text Available The extent of land affected by degradation in Uganda ranges from 20% in relatively flat and vegetation-covered areas to 90% in the eastern and southwestern highlands. Land degradation has adversely affected smallholder agro-ecosystems including direct damage and loss of critical ecosystem services such as agricultural land/soil and biodiversity. This study evaluated the extent of bare grounds in Nakasongola, one of the districts in the Cattle Corridor of Uganda and the yield responses of maize (Zea mays and common bean (Phaseolus vulgaris L. to different tillage methods in the district. Bare ground was determined by a supervised multi-band satellite image classification using the Maximum Likelihood Classifier (MLC. Field trials on maize and bean grain yield responses to tillage practices used a randomized complete block design with three replications, evaluating conventional farmer practice (CFP; permanent planting basins (PPB; and rip lines, with or without fertilizer in maize and bean rotations. Bare ground coverage in the Nakasongola District was 187 km2 (11% of the 1741 km2 of arable land due to extreme cases of soil compaction. All practices, whether conventional or the newly introduced conservation farming practices in combination with fertilizer increased bean and maize grain yields, albeit with minimal statistical significance in some cases. The newly introduced conservation farming tillage practices increased the bean grain yield relative to conventional practices by 41% in PPBs and 43% in rip lines. In maize, the newly introduced conservation farming tillage practices increased the grain yield by 78% on average, relative to conventional practices. Apparently, conservation farming tillage methods proved beneficial relative to conventional methods on degraded soils, with the short-term benefit of increasing land productivity leading to better harvests and food security.

  18. Comparison of the lysis centrifugation method with the conventional blood culture method in cases of sepsis in a tertiary care hospital.

    Science.gov (United States)

    Parikh, Harshal R; De, Anuradha S; Baveja, Sujata M

    2012-07-01

    Physicians and microbiologists have long recognized that the presence of living microorganisms in the blood of a patient carries with it considerable morbidity and mortality. Hence, blood cultures have become critically important and frequently performed test in clinical microbiology laboratories for diagnosis of sepsis. To compare the conventional blood culture method with the lysis centrifugation method in cases of sepsis. Two hundred nonduplicate blood cultures from cases of sepsis were analyzed using two blood culture methods concurrently for recovery of bacteria from patients diagnosed clinically with sepsis - the conventional blood culture method using trypticase soy broth and the lysis centrifugation method using saponin by centrifuging at 3000 g for 30 minutes. Overall bacteria recovered from 200 blood cultures were 17.5%. The conventional blood culture method had a higher yield of organisms, especially Gram positive cocci. The lysis centrifugation method was comparable with the former method with respect to Gram negative bacilli. The sensitivity of lysis centrifugation method in comparison to conventional blood culture method was 49.75% in this study, specificity was 98.21% and diagnostic accuracy was 89.5%. In almost every instance, the time required for detection of the growth was earlier by lysis centrifugation method, which was statistically significant. Contamination by lysis centrifugation was minimal, while that by conventional method was high. Time to growth by the lysis centrifugation method was highly significant (P value 0.000) as compared to time to growth by the conventional blood culture method. For the diagnosis of sepsis, combination of the lysis centrifugation method and the conventional blood culture method with trypticase soy broth or biphasic media is advocable, in order to achieve faster recovery and a better yield of microorganisms.

  19. Evaluation of positional plagiocephaly: Conventional anthropometric measurement versus laser scanning method.

    Science.gov (United States)

    Nahles, Susanne; Klein, Martin; Yacoub, Anke; Neyer, Julia

    2018-01-01

    The incidence of plagiocephaly has increased in the 25 years since the "Back to Sleep" campaign in 1991 to prevent sudden infant death. Plagiocephaly is not considered to be a pathological condition. It is more of an esthetic impairment and could have potentially negative psychological or psychosocial consequences; therefore, treatment is recommended. The aim of this study is to compare conventional anthropometry and laser scanning - two different measurement methods - as diagnostic instruments for plagiocephaly. The present study also tests the measurement time of both methods and whether one method is easier on the patient than the other. A total of 44 children (21 girls, 23 boys) with a mean age of 8.8 months were involved in the present study. Of all patients, the following parameters were routinely evaluated using a standard protocol with the conventional anthropometric method and the scan method: head circumference, head length, head width, head diagonals, and distances ex-t. Furthermore, the time required to obtain measurements and the behavior of the children during measurement were documented. For statistical analysis, a t-test and a Wilcoxon test were used to analyze differences between the two methods. The results for head circumference showed a mean of 441.5 mm for the anthropometric measurements and 441.6 mm for the scan method, with no significant difference between the two methods. A significant difference was found regarding the head width, head length, diagonals, and distance ex-t. The measurement process using the scan method needed a mean of 579.6 s in contrast to the manual anthropometric method, which required a mean time of 180.5 s. In comparison with the conventional anthropometric method, measurements made with a 3D laser scanner yield inconsistent results. Moreover, the current state of technology of 3D cephalometry has no advantages compared with the conventional anthropometric method. Disadvantages worth mentioning appear to be the

  20. Sectional localization of a small hepatocellular carcinoma in the right hepatic lobe by computed tomography: Comparison between the conventional and portal vein tracing methods

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Chun-Gao [Seoul National University Hospital, Department of Radiology, Jongro-gu, Seoul (Korea, Republic of); The First Affiliated Hospital of Nanjing Medical University, Department of Interventional Radiology, Nanjing (China); Chung, Jin Wook; Hur, Saebeom; Lee, Myungsu; Kim, Hyo-Cheol; Jae, Hwan Jun; Yin, Yong-Hu; Kim, Young Il [Seoul National University Hospital, Department of Radiology, Jongro-gu, Seoul (Korea, Republic of); Ahn, Sang-bu [Dongnam Institution of Radiological and Medical Sciences, Department of Radiology, Busan (Korea, Republic of); Cho, Baik Hwan [Chonbuk National University Hospital, Department of Radiology, Jeonju (Korea, Republic of)

    2016-12-15

    To compare the accuracy of the conventional and portal vein tracing methods in the right hepatic lobe in multidetector computed tomography (MDCT). This retrospective study included patients with hepatocellular carcinoma (HCC) lesions in the right hepatic lobe who underwent multiphasic MDCT and C-arm CT hepatic arteriography (C-arm CTHA) for chemoembolization. The accuracies of the conventional and portal vein tracing methods were evaluated using C-arm CTHA as the gold standard. A total of 147 patients with 205 HCC nodules were included. The C-arm CTHA could identify all the tumour-feeding arteries and consequently demonstrated that 120 lesions were located in the anterior section, 78 in the posterior section, and 7 in the border zone. The accuracy rates of conventional vs. portal vein tracing methods were 71.7 % vs. 98.3 % for the anterior section lesions, 67.9 % vs. 96.2 % for the posterior section, and 28.6 % vs. 57.1 % for the border zone. The portal vein tracing method was more accurate than the conventional method (P<0.001). The portal vein tracing method should be used for sectional localization of HCCs in the right lobe, because it predicts the location more accurately than the conventional method. (orig.)

  1. Selecting the patients for morning report sessions: case-based vs. conventional method.

    Science.gov (United States)

    Rabiei, Mehdi; Saeidi, Masumeh; Kiani, Mohammad Ali; Amin, Sakineh Mohebi; Ahanchian, Hamid; Jafari, Seyed Ali; Kianifar, Hamidreza

    2015-08-01

    One of the most important issues in morning report sessions is the number of patients. The aim of this study was to investigate and compare the number of cases reported in the morning report sessions in terms of case-based and conventional methods from the perspective of pediatric residents of Mashhad University of Medical Sciences. The present study was conducted on 24 pediatric residents of Mashhad University of Medical Sciences in the academic year 2014-2015. In this survey, the residents replied to a 20-question researcher-made questionnaire that had been designed to measure the views of residents regarding the number of patients in the morning report sessions using case-based and conventional methods. The validity of the questionnaire was confirmed by experts' views and its reliability by calculating Cronbach's alpha coefficients. Data were analyzed by t-test analysis. The mean age of the residents was 30.852 ± 2.506, and 66.6% of them were female. The results showed that there was no significant relationship among the variables of academic year, gender, and residents' perspective to choosing the number of patients in the morning report sessions (P > 0.05). T-test analysis showed a significant relationship among the average scores of residents in the selection of the case-based method in comparison to the conventional method (P case-based morning report was preferred compared to the conventional method. This method makes residents pay more attention to the details of patients' issues and therefore helps them to better plan how to address patient problems and improve their differential diagnosis skills.

  2. Comparison of multimedia system and conventional method in patients’ selecting prosthetic treatment

    Directory of Open Access Journals (Sweden)

    Baghai R

    2010-12-01

    Full Text Available "nBackground and Aims: Selecting an appropriate treatment plan is one of the most critical aspects of dental treatments. The purpose of this study was to compare multimedia system and conventional method in patients' selecting prosthetic treatment and the time consumed."nMaterials and Methods: Ninety patients were randomly divided into three groups. Patients in group A, once were instructed using the conventional method of dental office and once multimedia system and time was measured in seconds from the beginning of the instruction till the patient had came to decision. The patients were asked about the satisfaction of the method used for them. In group B, patients were only instructed using the conventional method, whereas they were only exposed to soft ware in group C. The data were analyzed with Paired-T-test"n(in group A and T-test and Mann-Whitney test (in groups B and C."nResult: There was a significant difference between multimedia system and conventional method in group A and also between groups B and C (P<0.001. In group A and between groups B and C, patient's satisfaction about multimedia system was better. However, in comparison between groups B and C, multimedia system did not have a significant effect in treatment selection score (P=0.08."nConclusion: Using multimedia system is recommended due to its high ability in giving answers to a large number of patient's questions as well as in terms of marketing.

  3. Why conventional detection methods fail in identifying the existence of contamination events.

    Science.gov (United States)

    Liu, Shuming; Li, Ruonan; Smith, Kate; Che, Han

    2016-04-15

    Early warning systems are widely used to safeguard water security, but their effectiveness has raised many questions. To understand why conventional detection methods fail to identify contamination events, this study evaluates the performance of three contamination detection methods using data from a real contamination accident and two artificial datasets constructed using a widely applied contamination data construction approach. Results show that the Pearson correlation Euclidean distance (PE) based detection method performs better for real contamination incidents, while the Euclidean distance method (MED) and linear prediction filter (LPF) method are more suitable for detecting sudden spike-like variation. This analysis revealed why the conventional MED and LPF methods failed to identify existence of contamination events. The analysis also revealed that the widely used contamination data construction approach is misleading. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions

    OpenAIRE

    Ender, Andreas; Attin, Thomas; Mehl, Albert

    2016-01-01

    STATEMENT OF PROBLEM: Digital impression systems have undergone significant development in recent years, but few studies have investigated the accuracy of the technique in vivo, particularly compared with conventional impression techniques. PURPOSE: The purpose of this in vivo study was to investigate the precision of conventional and digital methods for complete-arch impressions. MATERIAL AND METHODS: Complete-arch impressions were obtained using 5 conventional (polyether, POE; vinylsilox...

  5. Genetic improvement of olive (Olea europaea L.) by conventional and in vitro biotechnology methods.

    Science.gov (United States)

    Rugini, E; Cristofori, V; Silvestri, C

    2016-01-01

    In olive (Olea europaea L.) traditional methods of genetic improvement have up to now produced limited results. Intensification of olive growing requires appropriate new cultivars for fully mechanized groves, but among the large number of the traditional varieties very few are suitable. High-density and super high-density hedge row orchards require genotypes with reduced size, reduced apical dominance, a semi-erect growth habit, easy to propagate, resistant to abiotic and biotic stresses, with reliably high productivity and quality of both fruits and oil. Innovative strategies supported by molecular and biotechnological techniques are required to speed up novel hybridisation methods. Among traditional approaches the Gene Pool Method seems a reasonable option, but it requires availability of widely diverse germplasm from both cultivated and wild genotypes, supported by a detailed knowledge of their genetic relationships. The practice of "gene therapy" for the most important existing cultivars, combined with conventional methods, could accelerate achievement of the main goals, but efforts to overcome some technical and ideological obstacles are needed. The present review describes the benefits that olive and its products may obtain from genetic improvement using state of the art of conventional and unconventional methods, and includes progress made in the field of in vitro techniques. The uses of both traditional and modern technologies are discussed with recommendations. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Conventional cable testing methods: strengths, weaknesses and possibilities

    International Nuclear Information System (INIS)

    Reynolds, P.H.

    1988-01-01

    The paper reviews the major conventional methods that can be used to test power plant cables. It assesses their usefulness in diagnosing the condition of the insulation of the cable and then proposes some possible directions for innovation. The methods examined are dc insulation resistance measurement, ac signal injection for continuous monitoring and fault location, and the ac measurement of capacitance and loss angle. Specific subjects considered are the effects of temperature, cable construction and installation, and the validity of insulation resistance or loss angle measurement. The innovative proposals refer to the use of automation in the measurement and of computer-based Expert Systems for the evaluation of the results

  7. A Conceptual Design and Analysis Method for Conventional and Unconventional Airplanes

    NARCIS (Netherlands)

    Elmendorp, R.J.M.; Vos, R.; La Rocca, G.

    2014-01-01

    A design method is presented that has been implemented in a software program to investigate the merits of conventional and unconventional transport airplanes. Design and analysis methods are implemented in a design tool capable of creating a conceptual design based on a set of toplevel requirements.

  8. REMOVAL OF URANIUM FROM DRINKING WATER BY CONVENTIONAL TREATMENT METHODS

    Science.gov (United States)

    The USEPA currently does not regulate uranium in drinking water but will be revising the radionuclide regulations during 1989 and will propose a maximum contaminant level for uranium. The paper presents treatment technology information on the effectiveness of conventional method...

  9. Comparison of Concept Mapping and Conventional Teaching Methods on Critical Thinking Skills of Nursing Students

    Directory of Open Access Journals (Sweden)

    Masoumeh Delaram

    2017-06-01

    Full Text Available Background and Objective: Development of critical thinking and practical skills has remained a serious and considerable challenge throughout the nursing educational system in Iran. Conventional methods of teaching such as lectures as the dominant method used in higher education system is a passive style which ignores critical thinking. Therefore, the aim of this study was to compare the effect of instruction by Concept-Mapping and conventional Method on critical thinking skills of nursing students. Materials and Methods:This quasi-experimental study was carried out on 70 nursing students of Tehran Nursing and Midwifery schoolwho were selected through convenient sampling method, then were divided randomly into the two equal Experimental and Control groups. Educational content was presented in the form of Concept-Mapping in the Experimental group and Lecture,Demonstration and Practicalexercises in the control group. Data collection included a demographic information and California Critical Thinking Skills (form B questionnairewhich was completed at the beginning and at the end of the fourth week of Instructional period. Data were analyzed using SPSS software (V: 21, descriptive and analytical Statistics; at the significant level P<0.05. Results: Before the intervention, the mean of critical thinking skill score was 9.71±2.66 in concept mapping group and 9.64 ± 2.14 in conventional group and the difference was not significant (P=0.121, but after the intervention, a significant difference was found between the intervention and conventionalgroup (15.20±2.71 vs 10.25±2.06, P=0.003. Conclusion: Using Concept mapping strategy in the education of nursing students may lead to developing critical thinking skills as one of the important missions of higher education. So it is recommended to usethis method in clinical nursing education.

  10. In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions.

    Science.gov (United States)

    Ender, Andreas; Attin, Thomas; Mehl, Albert

    2016-03-01

    Digital impression systems have undergone significant development in recent years, but few studies have investigated the accuracy of the technique in vivo, particularly compared with conventional impression techniques. The purpose of this in vivo study was to investigate the precision of conventional and digital methods for complete-arch impressions. Complete-arch impressions were obtained using 5 conventional (polyether, POE; vinylsiloxanether, VSE; direct scannable vinylsiloxanether, VSES; digitized scannable vinylsiloxanether, VSES-D; and irreversible hydrocolloid, ALG) and 7 digital (CEREC Bluecam, CER; CEREC Omnicam, OC; Cadent iTero, ITE; Lava COS, LAV; Lava True Definition Scanner, T-Def; 3Shape Trios, TRI; and 3Shape Trios Color, TRC) techniques. Impressions were made 3 times each in 5 participants (N=15). The impressions were then compared within and between the test groups. The cast surfaces were measured point-to-point using the signed nearest neighbor method. Precision was calculated from the (90%-10%)/2 percentile value. The precision ranged from 12.3 μm (VSE) to 167.2 μm (ALG), with the highest precision in the VSE and VSES groups. The deviation pattern varied distinctly according to the impression method. Conventional impressions showed the highest accuracy across the complete dental arch in all groups, except for the ALG group. Conventional and digital impression methods differ significantly in the complete-arch accuracy. Digital impression systems had higher local deviations within the complete arch cast; however, they achieve equal and higher precision than some conventional impression materials. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  11. Changing perspective on tissue processing - comparison of microwave histoprocessing method with the conventional method

    Directory of Open Access Journals (Sweden)

    G Shrestha

    2015-09-01

    Full Text Available Background: Histopathological examination of tissues requires sliver of formalin fixed tissue that has been chemically processed and then stained with Haematoxylin and Eosin. The time honored conventional method of tissue processing, which requires 12 to 13 hours for completion, is employed at majority of laboratories but is now seeing the

  12. [A comparative study of blood culture conventional method vs. a modified lysis/centrifugation technique for the diagnosis of fungemias].

    Science.gov (United States)

    Santiago, Axel Rodolfo; Hernández, Betsy; Rodríguez, Marina; Romero, Hilda

    2004-12-01

    The purpose of this work was to compare the efficacy of blood culture conventional method vs. a modified lysis/centrifugation technique. Out of 450 blood specimens received in one year, 100 where chosen for this comparative study: 60 from patients with AIDS, 15 from leukemic patients, ten from febrile neutropenic patients, five from patients with respiratory infections, five from diabetics and five from septicemic patients. The specimens were processed, simultaneously, according to the above mentioned methodologies with daily inspections searching for fungal growth in order to obtain the final identification of the causative agent. The number (40) of isolates recovered was the same using both methods, which included; 18 Candida albicans (45%), ten Candida spp. (25%), ten Histoplasma capsulatum (25%), and two Cryptococcus neoformans (5%). When the fungal growth time was compared by both methods, growth was more rapid when using the modified lysis/centrifugation technique than when using the conventional method. Statistical analysis revealed a significant difference (pcentrifugation technique showed to be more efficacious than the conventional one, and therefore the implementation of this methodology is highly recommended for the isolation of fungi from blood.

  13. Conventional imaging in paediatric uroradiology

    International Nuclear Information System (INIS)

    Riccabona, M.; Lindbichler, F.; Sinzig, M.

    2002-01-01

    Objective: To briefly describe basic conventional imaging in paediatric uroradiology. Method: The state of the art performance of standard imaging techniques (intravenous urography (IVU), voiding cystourethrography (VCU), and ultrasound (US)) is described, with emphasis on technical aspects, indications, and patient preparation such as adequate hydration. Only basic applications as used in routine clinical work are included. Result and conclusion: Conventional imaging methods are irreplaceable. They cover the majority of daily clinical routine queries, with consecutive indication of more sophisticated modalities in those patients who need additional imaging for establishing the final diagnosis or outlining therapeutic options

  14. Conventional imaging in paediatric uroradiology

    Energy Technology Data Exchange (ETDEWEB)

    Riccabona, M. E-mail: michael.riccabona@kfunigraz.ac.at; Lindbichler, F.; Sinzig, M

    2002-08-01

    Objective: To briefly describe basic conventional imaging in paediatric uroradiology. Method: The state of the art performance of standard imaging techniques (intravenous urography (IVU), voiding cystourethrography (VCU), and ultrasound (US)) is described, with emphasis on technical aspects, indications, and patient preparation such as adequate hydration. Only basic applications as used in routine clinical work are included. Result and conclusion: Conventional imaging methods are irreplaceable. They cover the majority of daily clinical routine queries, with consecutive indication of more sophisticated modalities in those patients who need additional imaging for establishing the final diagnosis or outlining therapeutic options.

  15. Effect of conventional cooking methods on lipid oxidation indices in lamb meat

    Directory of Open Access Journals (Sweden)

    A Pourkhalili

    2012-05-01

    Full Text Available Lipid oxidation is one of the most deteriorative reactions occurred in foodstuff which has harmful impacts on the both food quality and consumer's health. This study was designed to speculate the influence of three conventional cooking methods including boiling, frying and grilling on lipid oxidation parameters in cooked lamb meat. Sections of lamb meat from longissimus dorsi muscle, taken from native Lori-Bakhtiary sheep species were cut into uniform pieces and cooked using boiling, frying and roasting methods according to the cooking routine and tradition in Iranian society, in terms of temperature and time. Proximate compositions (moisture, lipid, ash and protein in the raw and cooked meat were determined using the standard methods of analysis. Moreover, weight loss was measured after each treatment. Lipid oxidation parameters such as peroxide value, conjugated diene and TBARS indices were measured in the raw and cooked samples. Evaluation of lipid oxidation parameters showed that peroxide value was significantly decreased in all cooked samples. In contrast, conjugated diene value was significantly increased in the fried and grilled samples (p

  16. Development of Extended Ray-tracing method including diffraction, polarization and wave decay effects

    Science.gov (United States)

    Yanagihara, Kota; Kubo, Shin; Dodin, Ilya; Nakamura, Hiroaki; Tsujimura, Toru

    2017-10-01

    Geometrical Optics Ray-tracing is a reasonable numerical analytic approach for describing the Electron Cyclotron resonance Wave (ECW) in slowly varying spatially inhomogeneous plasma. It is well known that the result with this conventional method is adequate in most cases. However, in the case of Helical fusion plasma which has complicated magnetic structure, strong magnetic shear with a large scale length of density can cause a mode coupling of waves outside the last closed flux surface, and complicated absorption structure requires a strong focused wave for ECH. Since conventional Ray Equations to describe ECW do not have any terms to describe the diffraction, polarization and wave decay effects, we can not describe accurately a mode coupling of waves, strong focus waves, behavior of waves in inhomogeneous absorption region and so on. For fundamental solution of these problems, we consider the extension of the Ray-tracing method. Specific process is planned as follows. First, calculate the reference ray by conventional method, and define the local ray-base coordinate system along the reference ray. Then, calculate the evolution of the distributions of amplitude and phase on ray-base coordinate step by step. The progress of our extended method will be presented.

  17. New practical method for evaluation of a conventional flat plate continuous pistachio dryer

    Energy Technology Data Exchange (ETDEWEB)

    Kouchakzadeh, Ahmad [Agri Machinery Engineering, Ilam University, Ilam (Iran, Islamic Republic of); Tavakoli, Teymur [Agri Machinery Engineering, Tarbyat Modares University, Tehran (Iran, Islamic Republic of)

    2011-07-15

    Highlights: {yields} Evaluation of a conventional flat plate continuous pistachio dryer with a new feasible method. {yields} Using thermophysical properties of air and matter. {yields} This manner could be utilized in similar dryer for other agricultural products. {yields} Method shows the heat loss and power separately. -- Abstract: Testing a dryer is necessary to evaluate its absolute and comparative performance with other dryers. A conventional flat plate continuous pistachio dryer was tested by a new practical method of mass and energy equilibrium. Results showed that the average power consumption and heat loss in three tests are 62.13 and 18.99 kW, respectively. The ratio of heat loss on power consumption showed that the efficiency of practical pistachios flat plate dryer is about 69.4%.

  18. New practical method for evaluation of a conventional flat plate continuous pistachio dryer

    International Nuclear Information System (INIS)

    Kouchakzadeh, Ahmad; Tavakoli, Teymur

    2011-01-01

    Highlights: → Evaluation of a conventional flat plate continuous pistachio dryer with a new feasible method. → Using thermophysical properties of air and matter. → This manner could be utilized in similar dryer for other agricultural products. → Method shows the heat loss and power separately. -- Abstract: Testing a dryer is necessary to evaluate its absolute and comparative performance with other dryers. A conventional flat plate continuous pistachio dryer was tested by a new practical method of mass and energy equilibrium. Results showed that the average power consumption and heat loss in three tests are 62.13 and 18.99 kW, respectively. The ratio of heat loss on power consumption showed that the efficiency of practical pistachios flat plate dryer is about 69.4%.

  19. In-Patient Treatment of Fibromyalgia: A Controlled Nonrandomized Comparison of Conventional Medicine versus Integrative Medicine including Fasting Therapy

    Directory of Open Access Journals (Sweden)

    Andreas Michalsen

    2013-01-01

    Full Text Available Fibromyalgia poses a challenge for therapy. Recent guidelines suggest that fibromyalgia should be treated within a multidisciplinary therapy approach. No data are available that evaluated multimodal treatment strategies of Integrative Medicine (IM. We conducted a controlled, nonrandomized pilot study that compared two inpatient treatment strategies, an IM approach that included fasting therapy and a conventional rheumatology (CM approach. IM used fasting cure and Mind-Body-Medicine as specific methods. Of 48 included consecutive patients, 28 were treated with IM, 20 with CM. Primary outcome was change in the Fibromyalgia Impact Questionnaire (FIQ score after the 2-week hospital stay. Secondary outcomes included scores of pain, depression, anxiety, and well being. Assessments were repeated after 12 weeks. At 2 weeks, there were significant improvements in the FIQ (P<0.014 and for most of secondary outcomes for the IM group compared to the CM group. The beneficial effects for the IM approach were reduced after 12 weeks and no longer statistically significant with the exception of anxiety. Findings indicate that a multimodal IM treatment with fasting therapy might be superior to CM in the short term and not inferior in the mid term. Longer-term studies are warranted to assess the clinical impact of integrative multimodal treatment in fibromyalgia.

  20. A new method to characterize dopant profiles in NMOSFETs using conventional transmission electron microscopy

    International Nuclear Information System (INIS)

    Kawamura, Kazuo; Ikeda, Kazuto; Terauchi, Masami

    2004-01-01

    We have developed a new method using conventional transmission electron microscopy (TEM) to obtain two dimensional dopant profiles in silicon and applied it to 40 nm-gate-length N + /p metal oxide semiconductor field effect transistors (MOSFETs). The results are consistent with those of selective-chemically etched samples observed by TEM. This method, using focused ion beam (FIB) sample preparation and conventional TEM, has the great advantage of simple sample preparation and high spatial resolution compared to other characterization methods, such as atomic capacitance microscopy, spreading resistance microscopy, and TEM combined with selective chemical etching. This indicates that this method can be applicable to the analysis of FETs at the 65 nm or smaller node

  1. Evaluation of head and neck cancer with 18F-FDG PET: a comparison with conventional methods

    International Nuclear Information System (INIS)

    Kresnik, E.; Mikosch, P.; Gallowitsch, H.J.; Heinisch, M.; Unterweger, O.; Kumnig, G.; Gomez, I.; Lind, P.; Kogler, D.; Wieser, S.; Gruenbacher, G.; Raunik, W.

    2001-01-01

    The aim of this study was to evaluate the usefulness of 18 F-FDG PET in the diagnosis and staging of primary and recurrent malignant head and neck tumours in comparison with conventional imaging methods [including ultrasonography, radiography, computed tomography (CT) and magnetic resonance imaging (MRI)], physical examination, panendoscopy and biopsies in clinical routine. A total of 54 patients (13 female, 41 male, age 61.3±12 years) were investigated retrospectively. Three groups were formed. In group I, 18 F-FDG PET was performed in 15 patients to detect unknown primary cancers. In group II, 24 studies were obtained for preoperative staging of proven head and neck cancer. In group III, 18 F-FDG PET was used in 15 patients to monitor tumour recurrence after radiotherapy and/or chemotherapy. In all patients, imaging was obtained at 70 min after the intravenous administration of 180 MBq 18 F-FDG. In 11 of the 15 patients in group I, the primary cancer could be found with 18 F-FDG, yielding a detection rate of 73.3%. In 4 of the 15 patients, CT findings were also suggestive of the primary cancer but were nonetheless equivocal. In these patients, 18 F-FDG showed increased 18 F-FDG uptake by the primary tumour, which was confirmed by histology. One patient had recurrence of breast carcinoma that could not be detected with 18 F-FDG PET, but was detected by CT. In three cases, the primary cancer could not be found with any imaging method. Among the 24 patients in group II investigated for staging purposes, 18 F-FDG PET detected a total of 13 local and three distant lymph node metastases, whereas the conventional imaging methods detected only nine local and one distant lymph node metastases. The results of 18 F-FDG PET led to an upstaging in 5/24 (20.8%) patients. The conventional imaging methods were false positive in 5/24 (20.8%). There was one false positive result using 18 F-FDG PET. Among the 15 patients of group III with suspected recurrence after radiotherapy

  2. Effectiveness of Video Demonstration over Conventional Methods in Teaching Osteology in Anatomy.

    Science.gov (United States)

    Viswasom, Angela A; Jobby, Abraham

    2017-02-01

    Technology and its applications are the most happening things in the world. So, is it in the field of medical education. This study was an evaluation of whether the conventional methods can compete with the test of technology. A comparative study of traditional method of teaching osteology in human anatomy with an innovative visual aided method. The study was conducted on 94 students admitted to MBBS 2014 to 2015 batch of Travancore Medical College. The students were divided into two academically validated groups. They were taught using conventional and video demonstrational techniques in a systematic manner. Post evaluation tests were conducted. Analysis of the mark pattern revealed that the group taught using traditional method scored better when compared to the visual aided method. Feedback analysis showed that, the students were able to identify bony features better with clear visualisation and three dimensional view when taught using the video demonstration method. The students identified visual aided method as the more interesting one for learning which helped them in applying the knowledge gained. In most of the questions asked, the two methods of teaching were found to be comparable on the same scale. As the study ends, we discover that, no new technique can be substituted for time tested techniques of teaching and learning. The ideal method would be incorporating newer multimedia techniques into traditional classes.

  3. A method to determine the number of nanoparticles in a cluster using conventional optical microscopes

    International Nuclear Information System (INIS)

    Kang, Hyeonggon; Attota, Ravikiran; Tondare, Vipin; Vladár, András E.; Kavuri, Premsagar

    2015-01-01

    We present a method that uses conventional optical microscopes to determine the number of nanoparticles in a cluster, which is typically not possible using traditional image-based optical methods due to the diffraction limit. The method, called through-focus scanning optical microscopy (TSOM), uses a series of optical images taken at varying focus levels to achieve this. The optical images cannot directly resolve the individual nanoparticles, but contain information related to the number of particles. The TSOM method makes use of this information to determine the number of nanoparticles in a cluster. Initial good agreement between the simulations and the measurements is also presented. The TSOM method can be applied to fluorescent and non-fluorescent as well as metallic and non-metallic nano-scale materials, including soft materials, making it attractive for tag-less, high-speed, optical analysis of nanoparticles down to 45 nm diameter

  4. In vivo precision of conventional and digital methods for obtaining quadrant dental impressions

    OpenAIRE

    Ender, Andreas; Zimmermann, Moritz; Attin, Thomas; Mehl, Albert

    2016-01-01

    OBJECTIVES Quadrant impressions are commonly used as alternative to full-arch impressions. Digital impression systems provide the ability to take these impressions very quickly; however, few studies have investigated the accuracy of the technique in vivo. The aim of this study is to assess the precision of digital quadrant impressions in vivo in comparison to conventional impression techniques. MATERIALS AND METHODS Impressions were obtained via two conventional (metal full-arch tray, CI, ...

  5. Conventional and digital radiographic methods in the detection of simulated external root resorptions: A comparative study

    Directory of Open Access Journals (Sweden)

    C J Sanjay

    2009-01-01

    Full Text Available Objective : To evaluate and compare the efficacy of conventional and digital radiographic methods in the detection of simulated external root resorption cavities and also to evaluate whether the detectability was influenced by resorption cavity sizes. Methods : Thirty-two selected teeth from human dentate mandibles were radiographed in orthoradial, mesioradial and distoradial aspect using conventional film (Insight Kodak F-speed; Eastman Kodak, Rochester, NY and a digital sensor (Trophy RVG advanced imaging system with 0.7mm and 1.0mm deep cavities prepared on their vestibular, mesial and distal surfaces at the cervical, middle and apical thirds. Three dental professionals, an endodontist, a radiologist and a general practitioner, evaluated the images twice with a one-week time interval. Results : No statistical significance was seen in the first observation for both conventional and digital radiographic methods in the detection of simulated external root resorptions and for small and medium cavities but statistical difference was noted in the second observation (P< 0.001 for both the methods. Conclusion : Considering the methodology and the overall results, conventional radiographic method (F-speed performed slightly better than the digital radiographic method in the detection of simulated radiographic method but better consistency was seen with the digital system. Overall size of the resorption cavity had no influence on the performance of both methods and suggests that initial external root resorption lesion is not well-appreciated with both the methods as compared to the advanced lesion.

  6. Arthroscopic release using F and C method versus conventional open release method in the treatment of gluteal muscle contracture: a comparative study.

    Science.gov (United States)

    Rai, Saroj; Jin, Shengyang; Meng, Chunqing; Chaudhary, Nabin; Tamang, Nira; Wang, Xiaohong; Liu, Xianzhe; Wang, Hong; Yang, Shuhua

    2017-03-16

    Gluteal muscle contracture (GMC), a debilitating disease, usually starts in early childhood after variable dose of injections around the buttock, if left untreated it worsens gradually and persists throughout the life. Because the disease mostly affects adolescents and adults, there is always an aesthetic concerns. Purposeof the study was to introduce the arthroscopic F and C method of GMC release, and to compare its clinical efficiency with conventional open surgery in terms of clinical outcome, rate of complications, patient's satisfactions, and recurrence. Between Jan 2013 and July 2015, 75 patients received an arthroscopic release with F and C release method and 71 patients received conventional open release of GMC. Primary surgeries in 16 years or older patients were included in the study. Two groups were compared clinically using Hip Outcome Scores - Activities of Daily Living Subscale (HOS-ADL), Hip Outcome Scores - Sports Subscale (HOS-Sports), Visual Analogue Scale (VAS), and Ye et al. evaluation criteria. No statistically significant differences were observed in Hip Outcome Scores - Activities of Daily Living Subscale (HOS-ADL) (P = 0.078), Hip Outcome Scores - Sports Subscale (HOS-Sports) (P = 0.340), and Visual Analogue Scale (VAS) (P = 0.524) between the two groups. 74 (98.7%) patients in the arthroscopic surgery group had good to excellent results, whereas 69 (97.1%) patients in the conventional open surgery group had good to excellent results (P = 0.727). No statistically significant difference was observed in recurrence rate (P = 0.612). Statistically significant differences were observed in incision length, use of post-operative analgesia, post-operative off-bed activity, and hospital stay. Complications were significantly higher in the conventional open surgery group (n = 21) than in the arthroscopic surgery group (n = 10) (P = 0.016). More importantly, cosmetic satisfaction was 100% in arthroscopic release group

  7. Methods for assessing phosphorus overfeeding on organic and conventional dairy farms.

    Science.gov (United States)

    Nordqvist, M; Holtenius, K; Spörndly, R

    2014-02-01

    Phosphorus (P) losses from dairy farms can severely damage aquatic ecosystems, so it is important to have tools to assess overfeeding of P. This study screened P intake and faecal excretion of different P fractions in dairy cows on conventional and organic farms, compared the P feeding level of the herds against the recommendations and analysed different sampling and analysis methods for assessing the general status of P feeding on the farms. The organic (n=14) and conventional farms (n=15) were of comparable size and were located in southern Sweden. On each farm, feed intake was registered for 10 cows representing four different lactation stages and their P intake was calculated and related to current recommendations. Faecal samples taken from the same cows were analysed for total P (TP) and soluble P. Milk production data for the cows were obtained from the Swedish official milk recording scheme. TP was determined in one slurry sample per farm. More than 70% of the cows studied, representing both conventional and organic herds, consumed P in excess of the recommendations. Conventional herds had higher P content in the ration than organic herds, and lactating cows in conventional herds had higher faecal concentrations of total and soluble P than those in organic herds. However in dry cows, the P content of the ration and soluble P and TP in faeces did not differ between the two management systems. Soluble P was well correlated to TP in faeces, and both were good indicators of P overfeeding.

  8. Assessment of the hardness of different orthodontic wires and brackets produced by metal injection molding and conventional methods

    Directory of Open Access Journals (Sweden)

    Shiva Alavi

    2017-01-01

    Conclusion: MIM orthodontic brackets exhibited hardness values much lower than those of SS orthodontic archwires and were more compatible with NiTi and beta-titanium archwires. A wide range of microhardness values has been reported for conventional orthodontic brackets and it should be considered that the manufacturing method might be only one of the factors affecting the mechanical properties of orthodontic brackets including hardness.

  9. COMPARATIVE EVALUATION OF CONVENTIONAL VERSUS RAPID METHODS FOR AMPLIFIABLE GENOMIC DNA ISOLATION OF CULTURED Azospirillum sp. JG3

    Directory of Open Access Journals (Sweden)

    Stalis Norma Ethica

    2013-12-01

    Full Text Available As an initial attempt to reveal genetic information of Azospirillum sp. JG3 strain, which is still absence despite of the strains' ability in producing valued enzymes, two groups of conventional methods: lysis-enzyme and column-kit; and two rapid methods: thermal disruption and intact colony were evaluated. The aim is to determine the most practical method for obtaining high-grade PCR product using degenerate primers as part of routine-basis protocols for studying the molecular genetics of the Azospirillal bacteria. The evaluation includes the assessment of electrophoresis gel visualization, pellet appearance, preparation time, and PCR result of extracted genomic DNA from each method. Our results confirmed that the conventional methods were more superior to the rapid methods in generating genomic DNA isolates visible on electrophoresis gel. However, modification made in the previously developed DNA isolation protocol giving the simplest and most rapid method of all methods used in this study for extracting PCR-amplifiable DNA of Azospirillum sp. JG3. Intact bacterial cells (intact colony loaded on electrophoresis gel could present genomic DNA band, but could not be completely amplified by PCR without thermal treatment. It can also be inferred from our result that the 3 to 5-min heating in dH2O step is critical for the pre-treatment of colony PCR of Azospirillal cells.

  10. Comparison of digital radiography and apex locator with the conventional method in root length determination of primary teeth

    Directory of Open Access Journals (Sweden)

    I E Neena

    2011-01-01

    Full Text Available Aim: The purpose of this study was to compare the Working length in primary teeth endodontics using intra oral digital radiovisiography and apex locator with conventional method for accuracy. Materials and Methods: This in vivo study was conducted on 30 primary teeth which were indicated for pulpectomy in the patients of the age group of 5-11 years All experimental teeth had adequate remaining tooth structure for rubber dam isolation and radiographicaly visible canals. Endodontic treatment was required due to irreversible pulpitis or pulp necrosis. A standardized intraoral periapical radiograph of the tooth was taken using conventional method by paralleling technique. The distance between the source and the tooth, tooth and the films were standardized using X-ray positioning device. During the pulpectomy procedure, the working length was determined by digital radiograph and apex locator. The measurements were then compared with the conventional method of root canal measurement technique for accuracy Result: From the results obtained we can conclude that Working length determined in primary molars using digital radiography and Apex locator did not show any significant difference in the mean working length measurements when compared with the conventional radiographic method. Conclusions: Apex locator is comparable to conventional radiograph in determining the working length without radiation in the primary teeth. Intraoral digital radiography is the safest method in determining the working length with significant reduction in radiation exposure.Hence, both the techniques can be safely used as alternatives to conventional radiographic methods in determining working length in primary teeth.

  11. DNA extraction on bio-chip: history and preeminence over conventional and solid-phase extraction methods.

    Science.gov (United States)

    Ayoib, Adilah; Hashim, Uda; Gopinath, Subash C B; Md Arshad, M K

    2017-11-01

    This review covers a developmental progression on early to modern taxonomy at cellular level following the advent of electron microscopy and the advancement in deoxyribonucleic acid (DNA) extraction for expatiation of biological classification at DNA level. Here, we discuss the fundamental values of conventional chemical methods of DNA extraction using liquid/liquid extraction (LLE) followed by development of solid-phase extraction (SPE) methods, as well as recent advances in microfluidics device-based system for DNA extraction on-chip. We also discuss the importance of DNA extraction as well as the advantages over conventional chemical methods, and how Lab-on-a-Chip (LOC) system plays a crucial role for the future achievements.

  12. VOLATILE CONSTITUENTS OF GINGER OIL PREPARED ACCORDING TO IRANIAN TRADITIONAL MEDICINE AND CONVENTIONAL METHOD: A COMPARATIVE STUDY.

    Science.gov (United States)

    Shirooye, Pantea; Mokaberinejad, Roshanak; Ara, Leila; Hamzeloo-Moghadam, Maryam

    2016-01-01

    Herbal medicines formulated as oils were believed to possess more powerful effects than their original plants in Iranian Traditional Medicine (ITM). One of the popular oils suggested for treatment of various indications was ginger oil. In the present study, to suggest a more convenient method of oil preparation (compared to the traditional method), ginger oil has been prepared according to both the traditional and conventional maceration methods and the volatile oil constituents have been compared. Ginger oil was obtained in sesame oil according to both the traditional way and the conventional (maceration) methods. The volatile oil of dried ginger and both oils were obtained by hydro-distillation and analyzed by gas chromatography/mass spectroscopy. Fifty five, fifty nine and fifty one components consisting 94 %, 94 % and 98 % of the total compounds were identified in the volatile oil of ginger, traditional and conventional oils, respectively. The most dominant compounds of the traditional and conventional oils were almost similar; however they were different from ginger essential oil which has also been to possess limited amounts of anti-inflammatory components. It was concluded that ginger oil could be prepared through maceration method and used for indications mentioned in ITM.

  13. Survey and assessment of conventional software verification and validation methods

    International Nuclear Information System (INIS)

    Miller, L.A.; Groundwater, E.; Mirsky, S.M.

    1993-04-01

    By means of a literature survey, a comprehensive set of methods was identified for the verification and validation of conventional software. The 134 methods so identified were classified according to their appropriateness for various phases of a developmental lifecycle -- requirements, design, and implementation; the last category was subdivided into two, static testing and dynamic testing methods. The methods were then characterized in terms of eight rating factors, four concerning ease-of-use of the methods and four concerning the methods' power to detect defects. Based on these factors, two measurements were developed to permit quantitative comparisons among methods, a Cost-Benefit metric and an Effectiveness Metric. The Effectiveness Metric was further refined to provide three different estimates for each method, depending on three classes of needed stringency of V ampersand V (determined by ratings of a system's complexity and required-integrity). Methods were then rank-ordered for each of the three classes in terms of their overall cost-benefits and effectiveness. The applicability was then assessed of each method for the four identified components of knowledge-based and expert systems, as well as the system as a whole

  14. Use of non-conventional tests for the diagnosis of brucellosis

    International Nuclear Information System (INIS)

    Biancifiori, F.

    1998-01-01

    A number of non-conventional tests to complement traditional diagnostic methods for Brucellosis were established and assessed in order to verify whether the adoption of a panel of methods combined to alternative sampling strategies would increase the possibility of detecting low levels of Brucella spp. antibodies or microorganisms. The diagnostic performance of each test was established by means of reference standards and compared with conventional screening and confirmatory tests under field conditions. Non-conventional tests assessed for detecting Brucella organisms included: an agglutination method using a monoclonal antibody for an early and specific detection of Brucella spp. from colonies, polymerase chain reaction (PCR) for detection of Brucella spp in raw milk. Methods for detecting Brucella spp. antibodies included an ELISA test applied to cow milk, evaluation of milk-ELISA test through repeated sampling and ELISA in milk for the diagnosis of ovine brucellosis. The adopted strategy of repeated milk testing in dairy cows using ELISA increased the chance of identification of positive animals. (author)

  15. Influence of Detection Methods in Characterizing Escherichia coli O157:H7 in Raw Goat Meat Using Conventional and Molecular Methods.

    Science.gov (United States)

    Tabashsum, Zajeba; Nazneen, Mafruha; Ahsan, C R; Bari, M L; Yasmin, M

    2016-01-01

     Presence of Escherichia coli O157:H7 on fresh goat meat samples (n= 40) of Dhaka city was analyzed using conventional and molecular methods. A total of 86 presumptive E. coli O157:H7 colonies were isolated from 60% of the samples using selective agar plating method. After conventional biochemical assay followed by API 20E assay, only 11 isolates were found to be E. coli O157:H7. Further serological test identified only four isolates that has strong agglutination reaction against anti-H7 sensitized latex. The biochemically and serologically confirmed isolates were then screened for major virulence factors include eaeA, rfbE, fliC, stx1 and stx2 genes by PCR. PCR analysis of positive isolates showed, 10 isolates were eaeA and rfbE genes positive but fliC gene was only in six, indicating that these isolates were H7 positive with flagellum antigens which might not expressed or detected in serotyping tests. Multiplex PCR against eaeA, stx1 and stx2 genes of the isolates showed similar results as when done individually. These results revealed that only 7% of the primary presumptive E. coli O157:H7 was found to be stx producing E. coli O157:H7 and thus greatly influenced the detection of the pathogen in meat samples.

  16. Comparative evaluation of the anti-diabetic activity of Pterocarpus marsupium Roxb. heartwood in alloxan induced diabetic rats using extracts obtained by optimized conventional and non conventional extraction methods.

    Science.gov (United States)

    Devgan, Manish; Nanda, Arun; Ansari, Shahid Husain

    2013-09-01

    The aim of the present study was to assess the anti-diabetic activity of Pterocarpus marsupium Roxb. heartwood in alloxan induced diabetic rats using extracts obtained by optimized conventional and non conventional extraction methods. Aqueous and ethanol extracts of Pterocarpus marsupium heartwood were prepared by conventional methods (infusion, decoction, maceration and percolation) and non conventional methods, such as ultrasound-assisted extraction (UAE) and microwave-assisted extraction (MAE). The crude aqueous extracts were administered orally to both normal and alloxan induced male albino rats (Sprague-Dawley strain). The experimental set up consisted of 48 male albino rats divided into 6 groups: Normal control, diabetic control (sterile normal saline, 1 ml/100 g body weight), standard (gliclazide, 25 mg/1000g of body weight), groups 4-6 (crude aqueous percolation, optimized UAE and MAE extract, 250 mg/1000g of body weight). In acute treatment, the reduction of blood glucose level was statistically significant with the oral administration of UAE and percolation aqueous extracts to the hyperglycemic rats. In sub-acute treatment, the UAE aqueous extract led to consistent and statistically significant (p<0.001) reduction in the blood glucose levels. There was no abnormal change in body weight of the hyperglycemic animals after 10 days of administration of plant extracts and gliclazide. This study justifies the traditional claim and provides a rationale for the use of Pterocarpus marsupium to treat diabetes mellitus. The antidiabetic activity of Pterocarpus marsupium can be enhanced by extracting the heartwood by non conventional method of UAE.

  17. Comparison between laser terahertz emission microscope and conventional methods for analysis of polycrystalline silicon solar cell

    Directory of Open Access Journals (Sweden)

    Hidetoshi Nakanishi

    2015-11-01

    Full Text Available A laser terahertz emission microscope (LTEM can be used for noncontact inspection to detect the waveforms of photoinduced terahertz emissions from material devices. In this study, we experimentally compared the performance of LTEM with conventional analysis methods, e.g., electroluminescence (EL, photoluminescence (PL, and laser beam induced current (LBIC, as an inspection method for solar cells. The results showed that LTEM was more sensitive to the characteristics of the depletion layer of the polycrystalline solar cell compared with EL, PL, and LBIC and that it could be used as a complementary tool to the conventional analysis methods for a solar cell.

  18. Effect of Chemistry Triangle Oriented Learning Media on Cooperative, Individual and Conventional Method on Chemistry Learning Result

    Science.gov (United States)

    Latisma D, L.; Kurniawan, W.; Seprima, S.; Nirbayani, E. S.; Ellizar, E.; Hardeli, H.

    2018-04-01

    The purpose of this study was to see which method are well used with the Chemistry Triangle-oriented learning media. This quasi experimental research involves first grade of senior high school students in six schools namely each two SMA N in Solok city, in Pasaman and two SMKN in Pariaman. The sampling technique was done by Cluster Random Sampling. Data were collected by test and analyzed by one-way anova and Kruskall Wallish test. The results showed that the high school students in Solok learning taught by cooperative method is better than the results of student learning taught by conventional and Individual methods, both for students who have high initial ability and low-ability. Research in SMK showed that the overall student learning outcomes taught by conventional method is better than the student learning outcomes taught by cooperative and individual methods. Student learning outcomes that have high initial ability taught by individual method is better than student learning outcomes that are taught by cooperative method and for students who have low initial ability, there is no difference in student learning outcomes taught by cooperative, individual and conventional methods. Learning in high school in Pasaman showed no significant difference in learning outcomes of the three methods undertaken.

  19. Conventional and Alternative Disinfection Methods of Legionella in Water Distribution Systems – Review

    Directory of Open Access Journals (Sweden)

    Pūle Daina

    2016-12-01

    Full Text Available Prevalence of Legionella in drinking water distribution systems is a widespread problem. Outbreaks of Legionella caused diseases occur despite various disinfectants are used in order to control Legionella. Conventional methods like thermal disinfection, silver/copper ionization, ultraviolet irradiation or chlorine-based disinfection have not been effective in the long term for control of biofilm bacteria. Therefore, research to develop more effective disinfection methods is still necessary.

  20. Characterization and stability studies of a novel liposomal cyclosporin A prepared using the supercritical fluid method: comparison with the modified conventional Bangham method

    Directory of Open Access Journals (Sweden)

    Karn PR

    2013-01-01

    Full Text Available Pankaj Ranjan Karn,1,3 Wonkyung Cho,1,3 Hee-Jun Park,1,3 Jeong-Sook Park,3 Sung-Joo Hwang1,21Yonsei Institute of Pharmaceutical Sciences, Yonsei University, Yeonsu-gu, Incheon, Republic of Korea; 2College of Pharmacy, Yonsei University, Yeonsu-gu, Incheon, Republic of Korea; 3College of Pharmacy, Chungnam National University, Yuseong-gu, Daejeon, Republic of KoreaAbstract: A novel method to prepare cyclosporin A encapsulated liposomes was introduced using supercritical fluid of carbon dioxide (SCF-CO2 as an antisolvent. To investigate the strength of the newly developed SCF-CO2 method compared with the modified conventional Bangham method, particle size, zeta potential, and polydispersity index (PDI of both liposomal formulations were characterized and compared. In addition, entrapment efficiency (EE and drug loading (DL characteristics were analyzed by reversed-phase high-performance liquid chromatography. Significantly larger particle size and PDI were revealed from the conventional method, while EE (% and DL (% did not exhibit any significant differences. The SCF-CO2 liposomes were found to be relatively smaller, multilamellar, and spherical with a smoother surface as determined by transmission electron microscopy. SCF-CO2 liposomes showed no significant differences in their particle size and PDI after more than 3 months, whereas conventional liposomes exhibited significant changes in their particle size. The initial yield (%, EE (%, and DL (% of SCF-CO2 liposomes and conventional liposomes were 90.98 ± 2.94, 92.20 ± 1.36, 20.99 ± 0.84 and 90.72 ± 2.83, 90.24 ± 1.37, 20.47 ± 0.94, respectively, which changed after 14 weeks to 86.65 ± 0.30, 87.63 ± 0.72, 18.98 ± 0.22 and 75.04 ± 8.80, 84.59 ± 5.13, 15.94 ± 2.80, respectively. Therefore, the newly developed SCF-CO2 method could be a better alternative compared with the conventional method and may provide a promising approach for large-scale production of liposomes

  1. In-vitro evaluation of the accuracy of conventional and digital methods of obtaining full-arch dental impressions.

    Science.gov (United States)

    Ender, Andreas; Mehl, Albert

    2015-01-01

    To investigate the accuracy of conventional and digital impression methods used to obtain full-arch impressions by using an in-vitro reference model. Eight different conventional (polyether, POE; vinylsiloxanether, VSE; direct scannable vinylsiloxanether, VSES; and irreversible hydrocolloid, ALG) and digital (CEREC Bluecam, CER; CEREC Omnicam, OC; Cadent iTero, ITE; and Lava COS, LAV) full-arch impressions were obtained from a reference model with a known morphology, using a highly accurate reference scanner. The impressions obtained were then compared with the original geometry of the reference model and within each test group. A point-to-point measurement of the surface of the model using the signed nearest neighbour method resulted in a mean (10%-90%)/2 percentile value for the difference between the impression and original model (trueness) as well as the difference between impressions within a test group (precision). Trueness values ranged from 11.5 μm (VSE) to 60.2 μm (POE), and precision ranged from 12.3 μm (VSE) to 66.7 μm (POE). Among the test groups, VSE, VSES, and CER showed the highest trueness and precision. The deviation pattern varied with the impression method. Conventional impressions showed high accuracy across the full dental arch in all groups, except POE and ALG. Conventional and digital impression methods show differences regarding full-arch accuracy. Digital impression systems reveal higher local deviations of the full-arch model. Digital intraoral impression systems do not show superior accuracy compared to highly accurate conventional impression techniques. However, they provide excellent clinical results within their indications applying the correct scanning technique.

  2. Ergonomic evaluation of conventional and improved methods of aonla pricking with women workers.

    Science.gov (United States)

    Rai, Arpana; Gandhi, Sudesh; Sharma, D K

    2012-01-01

    Conventional and improved methods of aonla pricking were evaluated ergonomically on an experiment conducted for 20 minute with women workers. The working heart rate, energy expenditure rate, total cardiac cost of work and physiological cost of work with conventional tools varied from 93-102 beats.min-1, 6-7.5 kJ.min-1, 285-470 beats, 14 -23 beats.min-1 while with machine varied from 96-105 beats.min-1, 6.5-8 kJ.min-1 , 336-540 beats, 16-27 beats.min-1 respectively. OWAS score for conventional method was 2 indicating corrective measures in near future while with machine was 1 indicating no corrective measures. Result of Nordic Musculoskeletal Questionnaire revealed that subjects complaint of pain in back, neck, right shoulder and right hand due to unnatural body posture and repetitive movement with hand tool. Moreover pricking was carried out in improper lighting conditions (200-300 lux) resulting into finger injuries from sharp edges of hand tool, whereas with machine no such problems were observed. Output with machine increased thrice than hand pricking in a given time. Machine was found useful in terms of saving time, increased productivity, enhanced safety and comfort as involved improved posture, was easy to handle and operate, thus increasing efficiency of the worker leading to better quality of life.

  3. Comparison of the efficacy of conventional slow freezing and rapid cryopreservation methods for bovine embryos

    NARCIS (Netherlands)

    Wagtendonk-de Leeuw, van A.M.; Daas, den J.H.; Kruip, T.A.; Rail, W.F.

    1995-01-01

    Day 7 bovine morulae and early blastocysts were randomly assigned to one of four cryopreservation methods: (i) a modified conventional controlled slow freezing and stepwise dilution after thawing; and three methods which enable direct transfer of the embryo into the recipient upon thawing: (ii)

  4. Evaluation of stream discharges measurement using radioisotope and conventional method at Sungai Weng catchment area, Kedah

    International Nuclear Information System (INIS)

    Nazrul Hizam Yusoff and Wan Zakaria Wan MuhdTahir

    2006-01-01

    A number of discharge measurements using radioisotope and current metering techniques at selected streams in Sg. Weng Experimental Catchment were conducted by MINT and JPS gauging teams starting from 2003-2005. This study aims to prepare stage-discharge relationships or rating curves of the selected streams during variable flow conditions. The rating curve of the stream is one of the important parameters and usually appraised in certain routine operations of hydrological studies. It may be used in the planning of water resources management and flood control scheme. The radioisotope method employed in this study involved the injection of short-lived radioisotope tracer, that is, technetium-99m ( 99m Tc having its half-life ∼ 6.023 hrs) which was supplied from a high activity technetium generator (55.5 Gbq). Measurement of stream discharges were concurrently undertaken by JPS staff using a current meter type 0TT-C2 mounted on a wading rod at selected gauging stations for comparison purposes. Methodologies from the two methods of discharge measurements, comparison of results and identifying the uncertainties (errors) in performing the measurement during low, medium and high turbulent flows were explained in this paper. Generally, the entire results of streamflow data (2003-2005) measured by both methods during low flows (Q 3 /s) exhibit almost comparable values to each other. However, for moderate flows (1.0 m 3 /s 3 /s), the different in gauging results are slightly higher using radioisotope method ( i.e. Q isotope > Q current meter and may goes up to 40%) , and during high turbulent flows (Q>6.0 m 3 /s) the radioisotope method presented more than 40% higher discharge values as compared to the measurement made by the conventional current-meter. Observation made on site anticipated that inaccurate gauging data measured by conventional means during high flow and turbulent conditions are expected. The average estimated measurement error associated with isotope method

  5. Calculation method of rate and area of sedimentation, by non-conventional mathematical process of data treatment

    International Nuclear Information System (INIS)

    Cota, P.L.

    1987-01-01

    The used methods for calculating the rate and area of sedimentation are based in techniques of graphical resolution. The solution of the problem by a mathematical resolution, using computational methods, is more fast and more accuracy. The comparison between the results from this methods and the conventional method is shown. (E.G.) [pt

  6. Paris Convention on third party liability in the field of nuclear energy and Brussels Convention Supplementary to the Paris Convention

    International Nuclear Information System (INIS)

    1989-01-01

    This new bilingual (English and French) edition of the 1960 Paris Convention and 1963 Brussels Supplementary Convention incorporates the provisions of the Protocols which amended each of them on two occasions, in 1964 and 1982. The Expose des motifs to the Paris Convention, as revised in 1982 is also included in this pubication. (NEA) [fr

  7. Climate change convention

    International Nuclear Information System (INIS)

    Russell, D.

    1992-01-01

    Principles that guide Canada's Green Plan with respect to global warming are outlined. These include respect for nature, meeting environmental goals in an economically beneficial manner, efficient use of resources, shared responsibilities, federal leadership, and informed decision making. The policy side of the international Framework Convention on Climate Change is then discussed and related to the Green Plan. The Convention has been signed by 154 nations and has the long-term objective of stabilizing anthropogenic greenhouse gas concentrations in the atmosphere at levels that prevent dangerous interference with the climate system. Some of the Convention's commitments toward achieving that objective are only applicable to the developed countries. Five general areas of commitment are emissions reductions, assistance to developing countries, reporting requirements, scientific and socioeconomic research, and education. The most controversial area is that of limiting emissions. The Convention has strong measures for public accountability and is open to future revisions. Canada's Green Plan represents one country's response to the Convention commitments, including a national goal to stabilize greenhouse gas emissions at the 1990 level by the year 2000

  8. Comparison of the Lysis Centrifugation Method with the Conventional Blood Culture Method in Cases of Sepsis in a Tertiary Care Hospital

    OpenAIRE

    Parikh, Harshal R; De, Anuradha S; Baveja, Sujata M

    2012-01-01

    Introduction : Physicians and microbiologists have long recognized that the presence of living microorganisms in the blood of a patient carries with it considerable morbidity and mortality. Hence, blood cultures have become critically important and frequently performed test in clinical microbiology laboratories for diagnosis of sepsis. Objectives: To compare the conventional blood culture method with the lysis centrifugation method in cases of sepsis. Materials and Methods: Two hundred ...

  9. Assessment of the hardness of different orthodontic wires and brackets produced by metal injection molding and conventional methods.

    Science.gov (United States)

    Alavi, Shiva; Kachuie, Marzie

    2017-01-01

    This study was conducted to assess the hardness of orthodontic brackets produced by metal injection molding (MIM) and conventional methods and different orthodontic wires (stainless steel, nickel-titanium [Ni-Ti], and beta-titanium alloys) for better clinical results. A total of 15 specimens from each brand of orthodontic brackets and wires were examined. The brackets (Elite Opti-Mim which is produced by MIM process and Ultratrimm which is produced by conventional brazing method) and the wires (stainless steel, Ni-Ti, and beta-titanium) were embedded in epoxy resin, followed by grinding, polishing, and coating. Then, X-ray energy dispersive spectroscopy (EDS) microanalysis was applied to assess their elemental composition. The same specimen surfaces were repolished and used for Vickers microhardness assessment. Hardness was statistically analyzed with Kruskal-Wallis test, followed by Mann-Whitney test at the 0.05 level of significance. The X-ray EDS analysis revealed different ferrous or co-based alloys in each bracket. The maximum mean hardness values of the wires were achieved for stainless steel (SS) (529.85 Vickers hardness [VHN]) versus the minimum values for beta-titanium (334.65 VHN). Among the brackets, Elite Opti-Mim exhibited significantly higher VHN values (262.66 VHN) compared to Ultratrimm (206.59 VHN). VHN values of wire alloys were significantly higher than those of the brackets. MIM orthodontic brackets exhibited hardness values much lower than those of SS orthodontic archwires and were more compatible with NiTi and beta-titanium archwires. A wide range of microhardness values has been reported for conventional orthodontic brackets and it should be considered that the manufacturing method might be only one of the factors affecting the mechanical properties of orthodontic brackets including hardness.

  10. Exposure to radiation through the residual activity of waste treated by conventional methods

    International Nuclear Information System (INIS)

    Deckert, A.; Hoppe, G.; John, T.; Thierfeldt, S.

    1993-01-01

    Data obtained by questionnaires provided information on the type, amount, nuclide vector and maximum permissible value of low-level radioactive residues that occur in nuclear installations of due to industrial, scientific and medical uses of radioactive materials and are officially released to be disposed of by conventional methods. The general legal background of waste disposal methods, in particular the official regulations surrounding the waste disposal law, were described. On this basis, parameters and maximum radioactive burdens were specifically defined for garbage dumps for refuse from private households and those for building rubbish. Investigations were carried out into exposure paths that may have a role in the radioactive doses taken up by personnel (inhalation) or the general population (ingestion) through contaminated water. The radiation dose attributable to those exposure paths were expressed in relation to a specific unit activity of waste (1 bq/G). A dose of 10 μ Sv/r was taken as a standard to define a threshold value for each individual nuclide released for conventional waste disposal. It appears reasonable that such values are determined for groups of nuclides. (HP) [de

  11. Comparison of Tooth Color Change After Bleaching With Conventional and Different Light-Activated Methods.

    Science.gov (United States)

    Shahabi, Sima; Assadian, Hadi; Mahmoudi Nahavandi, Alireza; Nokhbatolfoghahaei, Hanieh

    2018-01-01

    Introduction: The demand for esthetic dental treatments is increasing in recent years mainly due to improved oral hygiene and better maintenance of oral health and teeth in older individuals. Bleaching of discolored anterior teeth is the most popular among esthetic dental treatments. Even individuals with sound teeth and adequate esthetics seek to have whiter teeth in the anterior region. The aim of this study was to evaluate tooth color changes following conventional in-office bleaching techniques compared to light-activated methods using different light sources. Methods: Seventy sound anterior teeth (devoided of caries and/or fracture), extracted for periodontal and orthodontic reasons were selected and allocated to 7 groups: (A) control, (B) conventional bleaching (C) LED-activated bleaching, (D) KTP laser-activated bleaching, (E) diode laser-activated bleaching, (F) Nd:YAG laser-activated bleaching and (G) CO2 laser-activated bleaching. Colorimetric evaluation was carried out before and after treatment using a spectrophotoradiometer. Data were analyzed by one- and two-way analysis of variance (ANOVA) as well as multiple comparison methods. Results: The results showed that all bleaching procedures were effective in reducing the yellowness index. However, the KTP laser-activated bleaching was significantly more effective than the other techniques in 95% confidence level. It was also seen that CO2 laser activated method has outperformed groups E, F and G and the conventional bleaching without light activation was not effective at all and represented similar results with the control group. Furthermore, the groups E and G had almost the same results in decreasing the yellowness index. Conclusion: The results showed that all bleaching techniques were effective however, the KTP laser-activated bleaching was significantly more efficient, closely followed by the CO2 laser-activated bleaching technique.

  12. [Study on friction and wear properties of dental zirconia ceramics processed by microwave and conventional sintering methods].

    Science.gov (United States)

    Guoxin, Hu; Ying, Yang; Yuemei, Jiang; Wenjing, Xia

    2017-04-01

    This study evaluated the wear of an antagonist and friction and wear properties of dental zirconia ceramic that was subjected to microwave and conventional sintering methods. Ten specimens were fabricated from Lava brand zirconia and randomly assigned to microwave and conventional sintering groups. A profile tester for surface roughness was used to measure roughness of the specimens. Wear test was performed, and steatite ceramic was used as antagonist. Friction coefficient curves were recorded, and wear volume were calculated. Finally, optical microscope was used to observe the surface morphology of zirconia and steatite ceramics. Field emission scanning electron microscopy was used to observe the microstructure of zirconia. Wear volumes of microwave and conventionally sintered zirconia were (6.940±1.382)×10⁻², (7.952±1.815) ×10⁻² mm³, respectively. Moreover, wear volumes of antagonist after sintering by the considered methods were (14.189±4.745)×10⁻², (15.813±3.481)×10⁻² mm³, correspondingly. Statistically significant difference was not observed in the wear resistance of zirconia and wear volume of steatite ceramic upon exposure to two kinds of sintering methods. Optical microscopy showed that ploughed surfaces were apparent in zirconia. The wear surface of steatite ceramic against had craze, accompanied by plough. Scanning electron microscopy showed that zirconia was sintered compactly when subjected to both conventional sintering and microwave methods, whereas grains of zirconia sintered by microwave alone were smaller and more uniform. Two kinds of sintering methods are successfully used to produce dental zirconia ceramics with similar friction and wear properties.
.

  13. CAM visual stimulation with conventional method of occlusion treatment in amblyopia: a randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Ali Reza Jafari

    2014-04-01

    Conclusion: Using of CAM visual stimulation along with conventional occlusion will further improve visual acuity and stereopsis in amblyopic children. These findings recommended the CAM visual stimulation as an accompanying and complementary method in amblyopia treatment.

  14. Choledochal cyst: Comparison of MR and conventional cholangiography

    International Nuclear Information System (INIS)

    Kim, S.H.; Lim, J.H.; Yoon, H.-K.; Han, B.K.; Lee, S.K.; Kim, Y.I.

    2000-01-01

    AIMS: To assess the diagnostic value of magnetic resonance (MR) cholangiography versus conventional cholangiography in patients with choledochal cyst and to determine whether MR cholangiography can be considered an alternative to conventional cholangiography. MATERIALS AND METHODS: Thirteen patients with choledochal cyst were examined by MR cholangiography and conventional cholangiograms. Magnetic resonance cholangiography employed T2-weighted axial and coronal fast spin-echo, single and multislab single-shot fast spin-echo sequences, including source images with maximum intensity projections. The diagnostic value of MR cholangiography and conventional cholangiograms was assessed and compared using the criteria of depiction of morphology, anomalous pancreaticobiliary duct union and demonstration of complications such as stones. A four-point diagnostic scale was applied to the delineation of the ductal anatomy with the Wilcoxon signed-ranks test and McNemar's test used for statistical analysis. RESULTS: The depiction of the choledochal cyst was significantly better with MR cholangiography than with conventional cholangiography (P 0.03). The detection rate of an anomalous pancreaticobiliary duct union was not significantly different with either method (P = 0.641), nor was the detection rate of bile duct stones (P = 0.375). CONCLUSION: Magnetic resonance cholangiography provides data equivalent to or superior to those from conventional cholangiography in evaluating choledochal cyst. Magnetic resonance cholangiography is recommended as a non-invasive examination of choice for the evaluation of choledochal cyst. Kim, S.H. (2000). Clinical Radiology 55, 378-383

  15. In vivo precision of conventional and digital methods for obtaining quadrant dental impressions.

    Science.gov (United States)

    Ender, Andreas; Zimmermann, Moritz; Attin, Thomas; Mehl, Albert

    2016-09-01

    Quadrant impressions are commonly used as alternative to full-arch impressions. Digital impression systems provide the ability to take these impressions very quickly; however, few studies have investigated the accuracy of the technique in vivo. The aim of this study is to assess the precision of digital quadrant impressions in vivo in comparison to conventional impression techniques. Impressions were obtained via two conventional (metal full-arch tray, CI, and triple tray, T-Tray) and seven digital impression systems (Lava True Definition Scanner, T-Def; Lava Chairside Oral Scanner, COS; Cadent iTero, ITE; 3Shape Trios, TRI; 3Shape Trios Color, TRC; CEREC Bluecam, Software 4.0, BC4.0; CEREC Bluecam, Software 4.2, BC4.2; and CEREC Omnicam, OC). Impressions were taken three times for each of five subjects (n = 15). The impressions were then superimposed within the test groups. Differences from model surfaces were measured using a normal surface distance method. Precision was calculated using the Perc90_10 value. The values for all test groups were statistically compared. The precision ranged from 18.8 (CI) to 58.5 μm (T-Tray), with the highest precision in the CI, T-Def, BC4.0, TRC, and TRI groups. The deviation pattern varied distinctly depending on the impression method. Impression systems with single-shot capture exhibited greater deviations at the tooth surface whereas high-frame rate impression systems differed more in gingival areas. Triple tray impressions displayed higher local deviation at the occlusal contact areas of upper and lower jaw. Digital quadrant impression methods achieve a level of precision, comparable to conventional impression techniques. However, there are significant differences in terms of absolute values and deviation pattern. With all tested digital impression systems, time efficient capturing of quadrant impressions is possible. The clinical precision of digital quadrant impression models is sufficient to cover a broad variety of

  16. Comparison of conventional culture methods and two commercial enzyme immunoassays for detection of Salmonella in porcine fecal samples and cecal contents

    DEFF Research Database (Denmark)

    Wegener, Henrik Caspar; Baggesen, Dorte Lau

    1997-01-01

    Two commercial enzyme immunoassays, designated EIA-1 and EIA-2, for the detection of salmonella in feces and cecal contents were compared to conventional culture methods. Out of 362 cecal content samples, 35 were positive by EIA-1 and 30 were positive by EIA-2 and conventional methods. Out of 189...

  17. Root canal preparation in endodontics: conventional versus laser methods

    Science.gov (United States)

    Goodis, Harold E.; White, Joel M.; Marshall, Sally J.; Marshall, Grayson W.; Moskowitz, Emrey

    1992-06-01

    Conventional cleaning and shaping of root canal systems employs hand and/or rotary instrumentation to remove the contents of the canal and shape the canal to receive a filling material. With the advent of the Nd:YAG laser system another method of accomplishing proper cleaning and shaping is evaluated. Single rooted teeth were radiographed bucco- lingually and mesio-distally and were divided into 2 groups. The first group was accessed and the root canal systems cleaned and shaped with a step back technique utilizing hand files and gates glidden burs. At completion of the procedure the teeth were again radiographed at the same positions as those prior to the procedure. The teeth were split longitudinally and examined under scanning electron microscopy to assess cleaning. The second group of teeth were accessed, and cleaning and shaping was accomplished using the Nd:YAG laser in combination with hand files and rotary instruments. These teeth were subjected to the same analysis as those in the first group. The before and after radiographs of each group were subjected to image analysis to determine effectiveness of the two methods in shaping the canal systems. We will discuss the ability of Nd:YAG to clean and shape root canal spaces and remove smear layer and organic tissue remnants from those areas.

  18. Diagnostic utility of the cell block method versus the conventional smear study in pleural fluid cytology.

    Science.gov (United States)

    Shivakumarswamy, Udasimath; Arakeri, Surekha U; Karigowdar, Mahesh H; Yelikar, Br

    2012-01-01

    The cytological examinations of serous effusions have been well-accepted, and a positive diagnosis is often considered as a definitive diagnosis. It helps in staging, prognosis and management of the patients in malignancies and also gives information about various inflammatory and non-inflammatory lesions. Diagnostic problems arise in everyday practice to differentiate reactive atypical mesothelial cells and malignant cells by the routine conventional smear (CS) method. To compare the morphological features of the CS method with those of the cell block (CB) method and also to assess the utility and sensitivity of the CB method in the cytodiagnosis of pleural effusions. The study was conducted in the cytology section of the Department of Pathology. Sixty pleural fluid samples were subjected to diagnostic evaluation for over a period of 20 months. Along with the conventional smears, cell blocks were prepared by using 10% alcohol-formalin as a fixative agent. Statistical analysis with the 'z test' was performed to identify the cellularity, using the CS and CB methods. Mc. Naemer's χ(2)test was used to identify the additional yield for malignancy by the CB method. Cellularity and additional yield for malignancy was 15% more by the CB method. The CB method provides high cellularity, better architectural patterns, morphological features and an additional yield of malignant cells, and thereby, increases the sensitivity of the cytodiagnosis when compared with the CS method.

  19. Teaching Dental Students to Understand the Temporomandibular Joint Using MRI: Comparison of Conventional and Digital Learning Methods.

    Science.gov (United States)

    Arús, Nádia A; da Silva, Átila M; Duarte, Rogério; da Silveira, Priscila F; Vizzotto, Mariana B; da Silveira, Heraldo L D; da Silveira, Heloisa E D

    2017-06-01

    The aims of this study were to evaluate and compare the performance of dental students in interpreting the temporomandibular joint (TMJ) with magnetic resonance imaging (MRI) scans using two learning methods (conventional and digital interactive learning) and to examine the usability of the digital learning object (DLO). The DLO consisted of tutorials about MRI and anatomic and functional aspects of the TMJ. In 2014, dental students in their final year of study who were enrolled in the elective "MRI Interpretation of the TMJ" course comprised the study sample. After exclusions for nonattendance and other reasons, 29 of the initial 37 students participated in the study, for a participation rate of 78%. The participants were divided into two groups: a digital interactive learning group (n=14) and a conventional learning group (n=15). Both methods were assessed by an objective test applied before and after training and classes. Aspects such as support and training requirements, complexity, and consistency of the DLO were also evaluated using the System Usability Scale (SUS). A significant between-group difference in the posttest results was found, with the conventional learning group scoring better than the DLO group, indicated by mean scores of 9.20 and 8.11, respectively, out of 10. However, when the pretest and posttest results were compared, both groups showed significantly improved performance. The SUS score was 89, which represented a high acceptance of the DLO by the users. The students who used the conventional method of learning showed superior performance in interpreting the TMJ using MRI compared to the group that used digital interactive learning.

  20. Comparison of INSURE method with conventional mechanical ventilation after surfactant administration in preterm infants with respiratory distress syndrome: therapeutic challenge.

    Directory of Open Access Journals (Sweden)

    Fatemeh Sadat Nayeri

    2014-08-01

    Full Text Available Administration of endotracheal surfactant is potentially the main treatment for neonates suffering from RDS (Respiratory Distress Syndrome, which is followed by mechanical ventilation. Late and severe complications may develop as a consequence of using mechanical ventilation. In this study, conventional methods for treatment of RDS are compared with surfactant administration, use of mechanical ventilation for a brief period and NCPAP (Nasal Continuous Positive Airway Pressure, (INSURE method ((Intubation, Surfactant administration and extubation. A randomized clinical trial study was performed, including all newborn infants with diagnosed RDS and a gestational age of 35 weeks or less, who were admitted in NICU of Valiasr hospital. The patients were then divided randomly into two CMV (Conventional Mechanical Ventilation and INSURE groups. Surfactant administration and consequent long-term mechanical ventilation were done in the first group (CMV group. In the second group (INSURE group, surfactant was administered followed by a short-term period of mechanical ventilation. The infants were then extubated, and NCPAP was embedded. The comparison included crucial duration of mechanical ventilation and oxygen therapy, IVH (Intraventricular Hemorrhage, PDA (Patent Ductus Arteriosus, air-leak syndromes, BPD (Broncho-Pulmonary Dysplasia and mortality rate. The need for mechanical ventilation in 5th day of admission was 43% decreased (P=0.005 in INSURE group in comparison to CMV group. A decline (P=0.01 in the incidence of IVH and PDA was also achieved. Pneumothorax, chronic pulmonary disease and mortality rates, were not significantly different among two groups. (P=0.25, P=0.14, P=0.25, respectively. This study indicated that INSURE method in the treatment of RDS decreases the need for mechanical ventilation and oxygen-therapy in preterm neonates. Moreover, relevant complications as IVH and PDA were observed to be reduced. Thus, it seems rationale to

  1. Screening for depression in epilepsy clinics. A comparison of conventional and visual-analog methods.

    Science.gov (United States)

    Rampling, Jeremy; Mitchell, Alex J; Von Oertzen, Tim; Docker, James; Jackson, Jemima; Cock, Hannah; Agrawal, Niruj

    2012-10-01

    Depression is an important but underdiagnosed complication of epilepsy. This study compares potentially suitable screening tools head-to-head. We enrolled 266 attendees with a confirmed diagnosis of epilepsy at a specialized neurologic epilepsy service in London and compared verbal self-report and visual analog (VAS) screening methods for depression. These included two generic depression scales (Hospital Anxiety and Depression Scale [HADS], Beck Depression Inventory II [BDI-II]), one epilepsy specific scale (Neurological Disorders Depression Inventory for Epilepsy [NDDI-E]) and one new visual-analog scale (Emotional Thermometers [ET]). We used Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV) criteria for major depression and International Classification of Diseases, Tenth Revision (ICD-10) criteria for depressive episode as the reference standard. Against ICD-10-defined depression the most accurate scales by receiver operating characteristic (ROC) curve area were HADS Total (HADS-T, 0.924), BDI-II (0.898) and NDDI-E (0.897). New visual-analog methods had similar accuracy measured either in combination or individually. Although no test performed well in a case-finding role, several performed well as a rule-out initial step, owing to high negative predictive value and specificity. In this role, the optimal performing conventional tools were the HADS depression subsscale (HADS-D) and the NDDI-E and the optimal single VAS were the depression thermometer (DepT) and the distress thermometer (DT). Against DSM-IV- defined major depression, results were similar with optimal performance by the HADS-T, BDI-II, and NDDI-E, but here the anxiety thermometer (AnxT) as well as DepT and DT also offered good performance. Given that no test performed well in a case-finding role, we suggest that these tests are used as an initial first step to rule out patients who are unlikely to have depression. We suggest that the six-item NDDI-E or seven-item HADS

  2. Diagnostic utility of the cell block method versus the conventional smear study in pleural fluid cytology

    Directory of Open Access Journals (Sweden)

    Udasimath Shivakumarswamy

    2012-01-01

    Full Text Available Background: The cytological examinations of serous effusions have been well-accepted, and a positive diagnosis is often considered as a definitive diagnosis. It helps in staging, prognosis and management of the patients in malignancies and also gives information about various inflammatory and non-inflammatory lesions. Diagnostic problems arise in everyday practice to differentiate reactive atypical mesothelial cells and malignant cells by the routine conventional smear (CS method. Aims: To compare the morphological features of the CS method with those of the cell block (CB method and also to assess the utility and sensitivity of the CB method in the cytodiagnosis of pleural effusions. Materials and Methods: The study was conducted in the cytology section of the Department of Pathology. Sixty pleural fluid samples were subjected to diagnostic evaluation for over a period of 20 months. Along with the conventional smears, cell blocks were prepared by using 10% alcohol-formalin as a fixative agent. Statistical analysis with the ′z test′ was performed to identify the cellularity, using the CS and CB methods. Mc. Naemer′s χ2 test was used to identify the additional yield for malignancy by the CB method. Results: Cellularity and additional yield for malignancy was 15% more by the CB method. Conclusions: The CB method provides high cellularity, better architectural patterns, morphological features and an additional yield of malignant cells, and thereby, increases the sensitivity of the cytodiagnosis when compared with the CS method.

  3. Imaging method of brain surface anatomy structures using conventional T2-weighted MR images

    International Nuclear Information System (INIS)

    Hatanaka, Masahiko; Machida, Yoshio; Yoshida, Tadatoki; Katada, Kazuhiro.

    1992-01-01

    As a non-invasive technique for visualizing the brain surface structure by MRI, surface anatomy scanning (SAS) and the multislice SAS methods have been developed. Both techniques require additional MRI scanning to obtain images for the brain surface. In this paper, we report an alternative method to obtain the brain surface image using conventional T2-weighted multislice images without any additional scanning. The power calculation of the image pixel values, which is incorporated in the routine processing, has been applied in order to enhance the cerebrospinal fluid (CSF) contrast. We think that this method is one of practical approaches for imaging the surface anatomy of the brain. (author)

  4. National implementation of the UNECE convention on long-range transboundary air pollution (effects). Pt. 1. Deposition loads: methods, modelling and mapping results, trends

    Energy Technology Data Exchange (ETDEWEB)

    Gauger, Thomas [Federal Agricultural Research Centre, Braunschweig (DE). Inst. of Agroecology (FAL-AOE); Stuttgart Univ. (Germany). Inst. of Navigation; Haenel, Hans-Dieter; Roesemann, Claus [Federal Agricultural Research Centre, Braunschweig (DE). Inst. of Agroecology (FAL-AOE)

    2008-09-15

    The report on the implementation of the UNECE convention on long-range transboundary air pollution Pt.1, deposition loads (methods, modeling and mapping results, trends) includes the following chapters: Introduction, deposition on air pollutants used for the input for critical loads in exceeding calculations, methods applied for mapping total deposition loads, mapping wet deposition, wet deposition mapping results, mapping dry deposition, dry deposition mapping results, cloud and fog mapping results, total deposition mapping results, modeling the air concentration of acidifying components and heavy metals, agricultural emissions of acidifying and eutrophying species.

  5. Listeria spp. in broiler flocks: recovery rates and species distribution investigated by conventional culture and the EiaFoss method

    DEFF Research Database (Denmark)

    Petersen, Line Hedegård; Madsen, Mogens

    2000-01-01

    The occurrence of Listeria monocytogenes in samples from broiler houses and cloacal swabs taken at the abattoir was investigated. An automated immunobased method (EiaFoss) was used, and 42 samples were also analysed by conventional culture; both methods were based on a two-step selective enrichment....... monocytogenes in enrichment broths may lead to an underestimation of the prevalence of L. monocytogenes. Furthermore, as L. inocua was also detected by the EiaFoss method, a significant amount of bacterial confirmation work had to be done. Of 42 samples analysed by conventional culture, four yielded L. inocua......, of which two were not positive by EiaFoss....

  6. Detection of Staphylococcus aureus among coagulase positive staphylococci from animal origin based on conventional and molecular methods

    Directory of Open Access Journals (Sweden)

    Nikolina Velizarova Rusenova

    2017-03-01

    Full Text Available The present study aimed to detect Staphylococcus aureus (S. aureus among other coagulase positive staphylococci from animal origin by using conventional methods (biochemical tests and latex agglutination and a molecular method, based on the nuc gene, as the gold standard and to assess the usefulness of these methods. For this purpose, total of 344 staphylococcal isolates were collected and analysed. A total of 156 isolates suspicious for S. aureus were detected by a conventional biochemical method – 88 from cows, 18 from goats, 7 from pigs, 17 from poultry, 7 from rabbits and 19 from dogs. The majority of S. aureus strains gave typical biochemical reactions with the exception of 30 (19.2% and 25 (16% that were VP negative and weak positive in fermenting mannitol, respectively. Twelve strains were found to be non-haemolytic (7.7% and four strains did not ferment trehalose (2.6%. Other staphylococci were identified as S. pseudintermedius (n = 103, S. hyicus (n = 23 and the rest were coagulase-negative staphylococci. Latex agglutination test resulted in rapid positive reactions with S. aureus with exception of 5 strains (3.2% from cow mastitis milk. Positive agglutination reactions were also established with S. pseudintermedius, and S. hyicus. PCR confirmed all strains that were preliminary identified as S. aureus by amplification of 270 bp fragment of nuc gene specific for this species. The atypical reactions in certain strains established in this study have shown that the precise detection of S. aureus from animal origin should be done by combination of conventional and molecular methods.

  7. Comparative study on flow rate measurement by nuclear and conventional methods in selected rivers at Ulu Langat district, Selangor

    Energy Technology Data Exchange (ETDEWEB)

    Wan Mohamad Tahir, Wan Zakaria; Mohamad, Daud; Hamzah, Abdul Razak; Yusuf, Johari Mohamad; Aziz Wan Mohamad, Wan Abdul

    1986-06-01

    A radiotracer technique using Tc-99 to measure flows of small rivers was introduced in Malaysia. Three rivers in the Ulu Langat District were selected for a comparative study on flow rate determination by conventional and radioisotope methods. Radioisotopic approach, comprising injection procedures, calibration, mixing length and safety aspects are discussed. The results measured by radioisotope method are compared to the Drainage and Irrigation Department's (DID's) discharge curves data collected from 1980 to 1982 which is calibrated using a current meter. The results are comparable and fall within the range obtained by conventional method. Related to this study, a comprehensive work on stream gauging of moderate and high flow rates using both methods is proposed to be carried out directly.

  8. Development of a quantitative safety assessment method for nuclear I and C systems including human operators

    International Nuclear Information System (INIS)

    Kim, Man Cheol

    2004-02-01

    Conventional PSA (probabilistic safety analysis) is performed in the framework of event tree analysis and fault tree analysis. In conventional PSA, I and C systems and human operators are assumed to be independent for simplicity. But, the dependency of human operators on I and C systems and the dependency of I and C systems on human operators are gradually recognized to be significant. I believe that it is time to consider the interdependency between I and C systems and human operators in the framework of PSA. But, unfortunately it seems that we do not have appropriate methods for incorporating the interdependency between I and C systems and human operators in the framework of Pasa. Conventional human reliability analysis (HRA) methods are not developed to consider the interdependecy, and the modeling of the interdependency using conventional event tree analysis and fault tree analysis seem to be, event though is does not seem to be impossible, quite complex. To incorporate the interdependency between I and C systems and human operators, we need a new method for HRA and a new method for modeling the I and C systems, man-machine interface (MMI), and human operators for quantitative safety assessment. As a new method for modeling the I and C systems, MMI and human operators, I develop a new system reliability analysis method, reliability graph with general gates (RGGG), which can substitute conventional fault tree analysis. RGGG is an intuitive and easy-to-use method for system reliability analysis, while as powerful as conventional fault tree analysis. To demonstrate the usefulness of the RGGG method, it is applied to the reliability analysis of Digital Plant Protection System (DPPS), which is the actual plant protection system of Ulchin 5 and 6 nuclear power plants located in Republic of Korea. The latest version of the fault tree for DPPS, which is developed by the Integrated Safety Assessment team in Korea Atomic Energy Research Institute (KAERI), consists of 64

  9. Methods of producing adsorption media including a metal oxide

    Science.gov (United States)

    Mann, Nicholas R; Tranter, Troy J

    2014-03-04

    Methods of producing a metal oxide are disclosed. The method comprises dissolving a metal salt in a reaction solvent to form a metal salt/reaction solvent solution. The metal salt is converted to a metal oxide and a caustic solution is added to the metal oxide/reaction solvent solution to adjust the pH of the metal oxide/reaction solvent solution to less than approximately 7.0. The metal oxide is precipitated and recovered. A method of producing adsorption media including the metal oxide is also disclosed, as is a precursor of an active component including particles of a metal oxide.

  10. Efficacious and safe orotracheal intubation for laboratory mice using slim torqueable guidewire-based technique: comparisons between a modified and a conventional method.

    Science.gov (United States)

    Su, Chieh-Shou; Lai, Hui-Chin; Wang, Chih-Yen; Lee, Wen-Lieng; Wang, Kuo-Yang; Yang, Ya-Ling; Wang, Li-Chun; Liu, Chia-Ning; Liu, Tsun-Jui

    2016-01-18

    Tracheal intubation of laboratory mice remains essential yet challenging for most researchers. The aim of this study was to investigate whether this procedure can be more efficiently and safely accomplished by a novel method using slim and torqueable guidewires to guide access to the trachea. This study was carried out in an animal laboratory affiliated to a tertiary medical center. Mice weighing 22 to 28 g were subjected to various open-chest experiments after being anesthetized with intraperitoneal ketamine (100 mg/kg) and lidocaine hydrochloride (10 mg/kg). The oropharyngeal cavity was opened with angled tissue forceps, and the trachea was transilluminated using an external light. The vocal cords were then crossed using either the Conventional method with a 38-mm-long, end-blunted stiff needle as a guide for insertion of a 22-gauge, 25-mm-long intravenous catheter into the trachea, or the Modified method utilizing using a 0.014-inch-thin torqueable wire as the guide to introduce an identical tube over it into the trachea. The epithelial integrity of the trachea was later examined histologically when the animals were sacrificed either immediately after the surgery or at 28 days post-surgery, depending on the corresponding research protocols. Orotracheal intubation was successfully completed in all mice using either the Conventional (N = 42) or the Modified method (N = 50). With the Modified method, intubation took less time (1.73 vs. 2.17 min, Modified vs. Conventional, p Conventional method. Histological analysis revealed a significantly lower incidence of immediate (0% vs. 39%, p Conventional method. Tracheal intubation for laboratory mice can be completed efficiently, safely and atraumatically using the proposed Modified method employing readily available inexpensive instruments.

  11. MAXILLARY INCISORS CHANGES DURING SPACE CLOSURE WITH CONVENTIONAL AND SKELETAL ANCHORAGE METHODS: A SYSTEMATIC REVIEW

    Directory of Open Access Journals (Sweden)

    Yasas Shri Nalaka JAYARATNE

    2017-12-01

    Full Text Available Purpose: The objective of this systematic review was to compare the antero-posterior, vertical and angular changes of maxillary incisors with conventional anchorage control techniques and mini-implant based space closure methods. Materials and Methods: The electronic databases Pubmed, Scopus, ISI Web of knowledge, Cochrane Library and Open Grey were searched for potentially eligible studies using a set of predetermined keywords. Full texts meeting the inclusion criteria as well as their references were manually searched. The primary outcome data (linear, angular, and vertical maxillary incisor changes and secondary outcome data (overbite changes, soft tissue changes, biomechanical factors, root resorption and treatment duration were extracted from the selected articles and entered into spreadsheets based on the type of anchorage used. The methodological quality of each study was assessed. Results: Six studies met the inclusion criteria. The amount of incisor retraction was greater with buccally placed mini-implants than conventional anchorage techniques. The incisor retraction with indirect anchorage from palatal mini-implants was less when compared with buccally placed mini-implants. Incisor intrusion occurred with buccal mini-implants, whereas extrusion was seen with conventional anchorage. Limited data on the biomechanical variables or adverse effects such as root resorption were reported in these studies. Conclusion: More RCT’s that take in to account relevant biomechanical variables and employ three-dimensional quantification of tooth movements are required to provide information on incisor changes during space closure.

  12. Manufacturing and characterization of ceramic pigment Zn1-xFexCr2O4 by synthetic non conventional methods

    International Nuclear Information System (INIS)

    Nieves, Leidy Johana Jaramillo; Baena, Oscar Jaime Restrepo

    2012-01-01

    The ceramic pigment with structure Zn 1-x Fe x Cr 2 O 4 (x = 0, 0.5, 1) was synthesized by non conventional methods of coprecipitation assisted by ultrasound and milling of high energy. This pigment was characterized by XRD, XRF, SEM, UV-VIS spectrophotometry and CIELab colorimetry. The aim of this work was studied two alternative methods to the traditional method of synthesis, evaluating the pigment properties, varying the stoichiometry, such as structure, composition, morphology and colorimetric coordinates. The results showed that is possible to obtain the desired crystalline structure at temperatures below 1000 ° C in both cases, also expected hues are obtained according to each stoichiometry, which shows the advantages of using methods non conventional when produce these pigments, since it has a higher controlling the composition, stoichiometry and is obtained at temperatures below compared with traditional ceramic method

  13. Microfluidic devices and methods including porous polymer monoliths

    Science.gov (United States)

    Hatch, Anson V; Sommer, Gregory J; Singh, Anup K; Wang, Ying-Chih; Abhyankar, Vinay V

    2014-04-22

    Microfluidic devices and methods including porous polymer monoliths are described. Polymerization techniques may be used to generate porous polymer monoliths having pores defined by a liquid component of a fluid mixture. The fluid mixture may contain iniferters and the resulting porous polymer monolith may include surfaces terminated with iniferter species. Capture molecules may then be grafted to the monolith pores.

  14. Intestinal preparation for colon enema with fosfo-soda fleet versus the conventional method

    International Nuclear Information System (INIS)

    Vecchioli Caldazza, A.; Celi, G.; De Franco, A.; Parrella, A.; Minordi, L.M.; Marano, P.

    1999-01-01

    The authors evaluate the possible optimization of a well-tolerated and versatile method of intestinal preparation able to adequately free the lumen and consequently improve diagnostic results with a lower risk of prolonged hospital stay for incorrectly prepared patients. They examined 40 patients, namely 20 men and 20 women referred to the Institute of radiology of the 'Sacro Cuore' Catholic University of Rome (Italy), Gastrointestinal tract unit, to undergo double contrast colonic enema. The statistical analysis of all data was performed with Wilcoxon test. Intestinal preparation with fosfo-soda fleet appeared to be definitely better than the conventional method relative to tolerance, while providing similarly satisfactory data relative to the other parameters [it

  15. Observability-Enhanced PMU Placement Considering Conventional Measurements and Contingencies

    Directory of Open Access Journals (Sweden)

    M. Esmaili

    2014-12-01

    Full Text Available Phasor Measurement Units (PMUs are in growing attention in recent power systems because of their paramount abilities in state estimation. PMUs are placed in existing power systems where there are already installed conventional measurements, which can be helpful if they are considered in PMU optimal placement. In this paper, a method is proposed for optimal placement of PMUs incorporating conventional measurements of zero injection buses and branch flow measurements using a permutation matrix. Furthermore, the effect of single branch outage and single PMU failure is included in the proposed method. When a branch with a flow measurement goes out, the network loses one observability path (the branch and one conventional measurement (the flow measurement. The permutation matrix proposed here is able to model the outage of a branch equipped with a flow measurement or connected to a zero injection bus. Also, measurement redundancy, and consequently measurement reliability, is enhanced without increasing the number of PMUs this implies a more efficient usage of PMUs than previous methods. The PMU placement problem is formulated as a mixed-integer linear programming that results in the global optimal solution. Results obtained from testing the proposed method on four well-known test systems in diverse situations confirm its efficiency.

  16. A coupling method for a cardiovascular simulation model which includes the Kalman filter.

    Science.gov (United States)

    Hasegawa, Yuki; Shimayoshi, Takao; Amano, Akira; Matsuda, Tetsuya

    2012-01-01

    Multi-scale models of the cardiovascular system provide new insight that was unavailable with in vivo and in vitro experiments. For the cardiovascular system, multi-scale simulations provide a valuable perspective in analyzing the interaction of three phenomenons occurring at different spatial scales: circulatory hemodynamics, ventricular structural dynamics, and myocardial excitation-contraction. In order to simulate these interactions, multiscale cardiovascular simulation systems couple models that simulate different phenomena. However, coupling methods require a significant amount of calculation, since a system of non-linear equations must be solved for each timestep. Therefore, we proposed a coupling method which decreases the amount of calculation by using the Kalman filter. In our method, the Kalman filter calculates approximations for the solution to the system of non-linear equations at each timestep. The approximations are then used as initial values for solving the system of non-linear equations. The proposed method decreases the number of iterations required by 94.0% compared to the conventional strong coupling method. When compared with a smoothing spline predictor, the proposed method required 49.4% fewer iterations.

  17. Ayurvedic versus conventional dietary and lifestyle counseling for mothers with burnout-syndrome: A randomized controlled pilot study including a qualitative evaluation.

    Science.gov (United States)

    Kessler, Christian S; Eisenmann, Clemens; Oberzaucher, Frank; Forster, Martin; Steckhan, Nico; Meier, Larissa; Stapelfeldt, Elmar; Michalsen, Andreas; Jeitler, Michael

    2017-10-01

    Ayurveda claims to be effective in the treatment of psychosomatic disorders by means of lifestyle and nutritional counseling. In a randomized controlled study mothers with burnout were randomized into two groups: Ayurvedic nutritional counseling (according to tradition), and conventional nutritional counseling (following the recommendations of a family doctor). Patients received five counseling sessions over twelve weeks. Outcomes included levels of burnout, quality of life, sleep, stress, depression/anxiety, and spirituality at three and six months. It also included a qualitative evaluation of the communication processes. We randomized thirty four patients; twenty three participants were included in the per protocol analysis. No significant differences were observed between the groups. However, significant and clinically relevant intra-group mean changes for the primary outcome burnout, and secondary outcomes sleep, stress, depression and mental health were only found in the Ayurveda group. The qualitative part of the study identified different conversational styles and counseling techniques between the two study groups. In conventional consultations questions tended to be category bound, while counseling-advice was predominantly admonitory. The Ayurvedic practitioner used open-ended interrogative forms, devices for displaying understanding, and positive re-evaluation more frequently, leading to an overall less asymmetrical interaction. We found positive effects for both groups, which however were more pronounced in the Ayurvedic group. The conversational and counseling techniques in the Ayurvedic group offered more opportunities for problem description by patients as well as patient-centered practice and resource-oriented recommendations by the physician. NCT01797887. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Conventional and improved cytotoxicity test methods of newly developed biodegradable magnesium alloys

    Science.gov (United States)

    Han, Hyung-Seop; Kim, Hee-Kyoung; Kim, Yu-Chan; Seok, Hyun-Kwang; Kim, Young-Yul

    2015-11-01

    Unique biodegradable property of magnesium has spawned countless studies to develop ideal biodegradable orthopedic implant materials in the last decade. However, due to the rapid pH change and extensive amount of hydrogen gas generated during biocorrosion, it is extremely difficult to determine the accurate cytotoxicity of newly developed magnesium alloys using the existing methods. Herein, we report a new method to accurately determine the cytotoxicity of magnesium alloys with varying corrosion rate while taking in-vivo condition into the consideration. For conventional method, extract quantities of each metal ion were determined using ICP-MS and the result showed that the cytotoxicity due to pH change caused by corrosion affected the cell viability rather than the intrinsic cytotoxicity of magnesium alloy. In physiological environment, pH is regulated and adjusted within normal pH (˜7.4) range by homeostasis. Two new methods using pH buffered extracts were proposed and performed to show that environmental buffering effect of pH, dilution of the extract, and the regulation of eluate surface area must be taken into consideration for accurate cytotoxicity measurement of biodegradable magnesium alloys.

  19. Influence of Kosher (Shechita) and conventional slaughter ...

    African Journals Online (AJOL)

    Influence of Kosher (Shechita) and conventional slaughter techniques on shear force, drip and cooking loss of beef. ... South African Journal of Animal Science ... force values for meat samples from cattle slaughtered by the Kosher method compared to those from cattle slaughtered by the conventional slaughter method.

  20. Convention on nuclear safety

    International Nuclear Information System (INIS)

    1994-01-01

    The Convention on Nuclear Safety was adopted on 17 June 1994 by Diplomatic Conference convened by the International Atomic Energy Agency at its Headquarters from 14 to 17 June 1994. The Convention will enter into force on the ninetieth day after the date of deposit with the Depository (the Agency's Director General) of the twenty-second instrument of ratification, acceptance or approval, including the instruments of seventeen States, having each at leas one nuclear installation which has achieved criticality in a reactor core. The text of the Convention as adopted is reproduced in the Annex hereto for the information of all Member States

  1. A review on mathematical methods of conventional and Islamic derivatives

    Science.gov (United States)

    Hisham, Azie Farhani Badrol; Jaffar, Maheran Mohd

    2014-12-01

    Despite the impressive growth of risk management tools in financial institutions, Islamic finance remains miles away behind the conventional institutions. Islamic finance products need to comply with the syariah law and prohibitions, therefore they can use fewer of the available risk management tools compared to conventional. Derivatives have proven to be the effective hedging technique and instrument that broadly being used in the conventional institutions to manage their risks. However, derivatives are not generally accepted as the legitimate products in Islamic finance and they remain controversial issues among the Islamic scholars. This paper reviews the evolution of derivatives such as forwards, futures and options and then explores the mathematical models that being used to solve derivatives such as random walk model, asset pricing model that follows Brownian motion and Black-Scholes model. Other than that, this paper also critically discuss the perspective of derivatives from Islamic point of view. In conclusion, this paper delivers the traditional Islamic products such as salam, urbun and istijrar that can be used to create building blocks of Islamic derivatives.

  2. Reinforcing the role of the conventional C-arm - a novel method for simplified distal interlocking

    Directory of Open Access Journals (Sweden)

    Windolf Markus

    2012-01-01

    Full Text Available Abstract Background The common practice for insertion of distal locking screws of intramedullary nails is a freehand technique under fluoroscopic control. The process is technically demanding, time-consuming and afflicted to considerable radiation exposure of the patient and the surgical personnel. A new concept is introduced utilizing information from within conventional radiographic images to help accurately guide the surgeon to place the interlocking bolt into the interlocking hole. The newly developed technique was compared to conventional freehand in an operating room (OR like setting on human cadaveric lower legs in terms of operating time and radiation exposure. Methods The proposed concept (guided freehand, generally based on the freehand gold standard, additionally guides the surgeon by means of visible landmarks projected into the C-arm image. A computer program plans the correct drilling trajectory by processing the lens-shaped hole projections of the interlocking holes from a single image. Holes can be drilled by visually aligning the drill to the planned trajectory. Besides a conventional C-arm, no additional tracking or navigation equipment is required. Ten fresh frozen human below-knee specimens were instrumented with an Expert Tibial Nail (Synthes GmbH, Switzerland. The implants were distally locked by performing the newly proposed technique as well as the conventional freehand technique on each specimen. An orthopedic resident surgeon inserted four distal screws per procedure. Operating time, number of images and radiation time were recorded and statistically compared between interlocking techniques using non-parametric tests. Results A 58% reduction in number of taken images per screw was found for the guided freehand technique (7.4 ± 3.4 (mean ± SD compared to the freehand technique (17.6 ± 10.3 (p p = 0.001. Operating time per screw (from first shot to screw tightened was on average 22% reduced by guided freehand (p = 0

  3. [Comparison between conventional methods, ChromAgar Candida® and PCR method for the identification of Candida species in clinical isolates].

    Science.gov (United States)

    Estrada-Barraza, Deyanira; Dávalos Martínez, Arturo; Flores-Padilla, Luis; Mendoza-De Elias, Roberto; Sánchez-Vargas, Luis Octavio

    2011-01-01

    The increase in the incidence of yeast species causing fungemia in susceptible immunocompromised patients in the last two decades and the low sensitivity of conventional blood culture has led to the need to develop alternative approaches for the early detection and identification of causative species. The aim of this study was to compare the usefulness of molecular testing by the polymerase chain reaction (PCR) and conventional methods to identify clinical isolates of different species, using the ID32C ATB system (bioMérieux, France), chromogenic culture Chromagar Candida® (CHROMagar, France) and morphogenesis in corn meal agar. We studied 79 isolates, in which the most prevalent species using the system ID32C and PCR was C. albicans, followed by C. tropicalis, C. glabrata and C .krusei. PCR patterns obtained for the identification of clinical isolates were stable and consistent in the various independent studies and showed good reproducibility, concluding that PCR with species-specific primers that amplify genes ITS1 and ITS2 for rRNA or topoisomerase II primers is a very specific and sensitive method for the identification of C. glabrata, C. krusei, C. albicans, and with less specificity for C. tropicalis. Copyright © 2010 Revista Iberoamericana de Micología. Published by Elsevier Espana. All rights reserved.

  4. No major differences found between the effects of microwave-based and conventional heat treatment methods on two different liquid foods.

    Science.gov (United States)

    Géczi, Gábor; Horváth, Márk; Kaszab, Tímea; Alemany, Gonzalo Garnacho

    2013-01-01

    Extension of shelf life and preservation of products are both very important for the food industry. However, just as with other processes, speed and higher manufacturing performance are also beneficial. Although microwave heating is utilized in a number of industrial processes, there are many unanswered questions about its effects on foods. Here we analyze whether the effects of microwave heating with continuous flow are equivalent to those of traditional heat transfer methods. In our study, the effects of heating of liquid foods by conventional and continuous flow microwave heating were studied. Among other properties, we compared the stability of the liquid foods between the two heat treatments. Our goal was to determine whether the continuous flow microwave heating and the conventional heating methods have the same effects on the liquid foods, and, therefore, whether microwave heat treatment can effectively replace conventional heat treatments. We have compared the colour, separation phenomena of the samples treated by different methods. For milk, we also monitored the total viable cell count, for orange juice, vitamin C contents in addition to the taste of the product by sensory analysis. The majority of the results indicate that the circulating coil microwave method used here is equivalent to the conventional heating method based on thermal conduction and convection. However, some results in the analysis of the milk samples show clear differences between heat transfer methods. According to our results, the colour parameters (lightness, red-green and blue-yellow values) of the microwave treated samples differed not only from the untreated control, but also from the traditional heat treated samples. The differences are visually undetectable, however, they become evident through analytical measurement with spectrophotometer. This finding suggests that besides thermal effects, microwave-based food treatment can alter product properties in other ways as well.

  5. No major differences found between the effects of microwave-based and conventional heat treatment methods on two different liquid foods.

    Directory of Open Access Journals (Sweden)

    Gábor Géczi

    Full Text Available Extension of shelf life and preservation of products are both very important for the food industry. However, just as with other processes, speed and higher manufacturing performance are also beneficial. Although microwave heating is utilized in a number of industrial processes, there are many unanswered questions about its effects on foods. Here we analyze whether the effects of microwave heating with continuous flow are equivalent to those of traditional heat transfer methods. In our study, the effects of heating of liquid foods by conventional and continuous flow microwave heating were studied. Among other properties, we compared the stability of the liquid foods between the two heat treatments. Our goal was to determine whether the continuous flow microwave heating and the conventional heating methods have the same effects on the liquid foods, and, therefore, whether microwave heat treatment can effectively replace conventional heat treatments. We have compared the colour, separation phenomena of the samples treated by different methods. For milk, we also monitored the total viable cell count, for orange juice, vitamin C contents in addition to the taste of the product by sensory analysis. The majority of the results indicate that the circulating coil microwave method used here is equivalent to the conventional heating method based on thermal conduction and convection. However, some results in the analysis of the milk samples show clear differences between heat transfer methods. According to our results, the colour parameters (lightness, red-green and blue-yellow values of the microwave treated samples differed not only from the untreated control, but also from the traditional heat treated samples. The differences are visually undetectable, however, they become evident through analytical measurement with spectrophotometer. This finding suggests that besides thermal effects, microwave-based food treatment can alter product properties in other

  6. Clinical outcomes for patients finished with the SureSmile™ method compared with conventional fixed orthodontic therapy

    Science.gov (United States)

    Alford, Timothy J.; Roberts, W. Eugene; Hartsfield, James K.; Eckert, George J.; Snyder, Ronald J.

    2016-01-01

    Objective Utilize American Board of Orthodontics (ABO) cast/radiographic evaluation (CRE) to compare a series of 63 consecutive patients, finished with manual wire bending (conventional) treatment, vs a subsequent series of 69 consecutive patients, finished by the same orthodontist using the SureSmile™ (SS) method. Materials and Methods Records of 132 nonextraction patients were scored by a calibrated examiner blinded to treatment mode. Age and discrepancy index (DI) between groups were compared by t-tests. A chi-square test was used to compare for differences in sex and whether the patient was treated using braces only (no orthopedic correction). Analysis of covariance tested for differences in CRE outcomes and treatment times, with sex and DI included as covariates. A logarithmic transformation of CRE outcomes and treatment times was used because their distributions were skewed. Significance was defined as P space closure; however, second-order root angulation (RA) was inferior. Conclusion SS patients were treated in less time to better CRE scores for first-order rotation (AR) and interproximal space closure (IC) but on the average, malocclusions were less complex and second order root alignment was inferior, compared with patients finished with manual wire bending. PMID:21261488

  7. Radiosurgical fistulotomy; an alternative to conventional procedure in fistula in ano.

    Science.gov (United States)

    Gupta, Pravin J

    2003-01-01

    Most surgeons continue to prefer the classic lay open technique [fistulotomy] as the gold standard of treatment in anal fistula. In this randomized study, a comparison is made between conventional fistulotomy and fistulotomy performed by a radio frequency device. One hundred patients of low anal fistula posted for fistulotomy were randomized prospectively to either a conventional or radio frequency technique. Parameters measured included time taken for the procedure, amount of blood loss, postoperative pain, return to work, and recurrence rate. The patient demographic was comparable in 2 groups. The radio frequency fistulotomy was quicker as compared to a conventional one [22 versus 37 minutes, p = 0.001], amount of bleeding was significantly less [47 ml versus 134 ml, p = 0.002], and hospital stay was less when patient was operated by radio frequency method [37 hours versus 56 hours in conventional method, p = 0.001]. The postoperative pain in the first 24 hours was more in conventional group [2 to 5 versus 0 to 3 on visual analogue scale]. The patients from radio frequency group resumed their duties early with a reduced healing period of the wounds [47 versus 64 days, p = 0.01]. The recurrence or failure rates were comparable in the radio frequency and conventional groups [2% versus 6%]. Fistulotomy procedure using a radio frequency technique has significant advantages over a conventional procedure with regard to operation time, blood loss, return to normal activity, and healing time of the wound.

  8. International conventions for measuring radioactivity of building materials

    International Nuclear Information System (INIS)

    Tan Chenglong

    2004-01-01

    In buildings, whether civil or industrial, natural radioactivity always occurs at different degrees in the materials (main building materials, decorative materials). Concerns on radioactivity from building materials is unavoidable for human living and developing. As a member of WTO, China's measuring method of radioactivity for building materials, including radionuclides limitation for building materials, hazard evaluation system etc, should keep accordance with the international rules and conventions. (author)

  9. Towards non-conventional methods of designing register-based epidemiological studies: An application to pediatric research.

    Science.gov (United States)

    Gong, Tong; Brew, Bronwyn; Sjölander, Arvid; Almqvist, Catarina

    2017-07-01

    Various epidemiological designs have been applied to investigate the causes and consequences of fetal growth restriction in register-based observational studies. This review seeks to provide an overview of several conventional designs, including cohort, case-control and more recently applied non-conventional designs such as family-based designs. We also discuss some practical points regarding the application and interpretation of family-based designs. Definitions of each design, the study population, the exposure and the outcome measures are briefly summarised. Examples of study designs are taken from the field of low birth-weight research for illustrative purposes. Also examined are relative advantages and disadvantages of each design in terms of assumptions, potential selection and information bias, confounding and generalisability. Kinship data linkage, statistical models and result interpretation are discussed specific to family-based designs. When all information is retrieved from registers, there is no evident preference of the case-control design over the cohort design to estimate odds ratios. All conventional designs included in the review are prone to bias, particularly due to residual confounding. Family-based designs are able to reduce such bias and strengthen causal inference. In the field of low birth-weight research, family-based designs have been able to confirm a negative association not confounded by genetic or shared environmental factors between low birth weight and the risk of asthma. We conclude that there is a broader need for family-based design in observational research as evidenced by the meaningful contributions to the understanding of the potential causal association between low birth weight and subsequent outcomes.

  10. Novel versus conventional antipsychotic drugs.

    Science.gov (United States)

    Love, R C

    1996-01-01

    Novel antipsychotic agents differ from conventional ones in several key characteristics, including effectiveness, adverse reactions, and receptor-binding profile. Most of the newer agents have an affinity for the serotonin 5HT2 receptor that is at least 10 times greater than that for the dopamine D2 receptor. This increased affinity for the serotonin receptor may be responsible for another distinguishing characteristic of novel antipsychotic agents--decreased frequency of extrapyramidal side effects. These side effects, which include pseudoparkinsonism, acute dystonias, and akathisia, frequently are the reason for noncompliance with conventional drug therapy. The newer drugs are often effective in patients resistant to treatment with conventional agents. They also appear to reduce the negative symptoms of schizophrenia in many patients.

  11. Detection and enumeration of Salmonella enteritidis in homemade ice cream associated with an outbreak: comparison of conventional and real-time PCR methods.

    Science.gov (United States)

    Seo, K H; Valentin-Bon, I E; Brackett, R E

    2006-03-01

    Salmonellosis caused by Salmonella Enteritidis (SE) is a significant cause of foodborne illnesses in the United States. Consumption of undercooked eggs and egg-containing products has been the primary risk factor for the disease. The importance of the bacterial enumeration technique has been enormously stressed because of the quantitative risk analysis of SE in shell eggs. Traditional enumeration methods mainly depend on slow and tedious most-probable-number (MPN) methods. Therefore, specific, sensitive, and rapid methods for SE quantitation are needed to collect sufficient data for risk assessment and food safety policy development. We previously developed a real-time quantitative PCR assay for the direct detection and enumeration of SE and, in this study, applied it to naturally contaminated ice cream samples with and without enrichment. The detection limit of the real-time PCR assay was determined with artificially inoculated ice cream. When applied to the direct detection and quantification of SE in ice cream, the real-time PCR assay was as sensitive as the conventional plate count method in frequency of detection. However, populations of SE derived from real-time quantitative PCR were approximately 1 log higher than provided by MPN and CFU values obtained by conventional culture methods. The detection and enumeration of SE in naturally contaminated ice cream can be completed in 3 h by this real-time PCR method, whereas the cultural enrichment method requires 5 to 7 days. A commercial immunoassay for the specific detection of SE was also included in the study. The real-time PCR assay proved to be a valuable tool that may be useful to the food industry in monitoring its processes to improve product quality and safety.

  12. Conventional versus molecular methods for diagnosis of tuberculosis in a tertiary care center: A study from Punjab

    Directory of Open Access Journals (Sweden)

    Shavi Nagpal

    2016-01-01

    Full Text Available Background: A fast and accurate diagnosis is necessary to control and eliminate tuberculosis (TB. There have been various studies evaluating the efficacy of polymerase chain reaction (PCR testing in clinical practice. Most of these studies have found PCR as a useful tool to diagnose TB and more so for the extra-pulmonary cases. Aims and Objectives: The aim of the study was to evaluate the results of TB by real-time PCR versus the conventional methods of diagnosis in a tertiary care center in Punjab. Materials and Methods: This study was done in a tertiary care center of Punjab to look for the results of clinical samples tested for TB using PCR, Ziehl–Neelsen staining and culture on Lowenstein–Jensen medium. 16S rRNA gene was used for Mycobacterium tuberculosis detection in PCR. This study included all samples tested for TB from July 2015 to October 2015. Results: A total of 214 samples were tested for TB using smear microscopy, culture and PCR (including 194 [90.6%] extra-pulmonary and 20 [9.3%] pulmonary samples. These included 76 cerebrospinal fluid, 30 pleural fluid, 42 tissues, 17 ascitic fluid, 13 urine, 15 bronchoalveolar lavage (BAL, 16 pus, and 5 sputum samples. Smear microscopy was positive in a total of 4 samples out of 214 (1.8%, which included 2 sputum, 1 tissue, and 1 ascitic fluid samples, while culture was positive for 6 samples (2.8% which included 2 sputum, 1 pus, 1 BAL, 1 tissue, and 1 ascitic fluid sample. The TB PCR results were positive in a total of 71 (33.1% samples out of 214. In addition, three samples also tested positive for Mycobacteria other than TB. Conclusion: PCR is a very rapid and accurate diagnostic tool for early detection of TB in particularly for extrapulmonary TB.

  13. Comparison on extraction yield of sennoside A and sennoside B from senna (Cassia angustifolia) using conventional and non conventional extraction techniques and their quantification using a validated HPLC-PDA detection method.

    Science.gov (United States)

    Dhanani, Tushar; Singh, Raghuraj; Reddy, Nagaraja; Trivedi, A; Kumar, Satyanshu

    2017-05-01

    Senna is an important medicinal plant and is used in many Ayurvedic formulations. Dianthraquinone glucosides are the main bioactive phytochemicals present in leaves and pods of senna. The extraction efficiency in terms of yield and composition of the extract of senna prepared using both conventional (cold percolation at room temperature and refluxing) and non conventional (ultrasound and microwave assisted solvent extraction as well as supercritical fluid extraction) techniques were compared in the present study. Also a rapid reverse phase HPLC-PDA detection method was developed and validated for the simultaneous determination of sennoside A and sennoside B in the different extracts of senna leaves. Ultrasound and microwave assisted solvent extraction techniques were more effective in terms of yield and composition of the extracts compared to cold percolation at room temperature and refluxing methods of extraction.

  14. Comparison of conventional full spine radiographs and fluoroscopic scanning method in young patients with idiopathic scoliosis; Vergleich von konventioneller Wirbelsaeulenganzaufnahme und fluoroskopischer Scan-Methode bei jungen Patienten mit idiopathischer Skoliose

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, J.; Kottke, R.; Claussen, C. [Abt. fuer Radiologische Diagnostik, Universitaetsklinikum Tuebingen (Germany); Kluba, T.; Niemeyer, T.; Hahnfeldt, T. [Klinik und Poliklinik fuer Orthopaedie, Universitaetsklinikum Tuebingen (Germany); Vonthein, R. [Inst. fuer Medizinische Biometrie, Universitaetsklinikum Tuebingen (Germany); Kamm, K.F. [Philips Medizin Systeme GmbH, Hamburg (Germany)

    2005-08-01

    Purpose: evaluation of low-dose full spine radiographs using fluoroscopic images for the assessment of the Cobb angle measurement in patients with scoliosis. Material and methods: twenty-one consecutive patients (aged 10-27 years, mean age 14 years) with a conventional full spine examination (film speed class 800) underwent a follow-up exam using digital pulsed fluoroscopy (Multi Diagnost 4, Philips Medical Systems, Eindhoven, The Netherlands). The mean follow-up was 9 months. During a synchronized scan with a C-arm speed of 4 cm/sec fluoroscopic images were stored with a pulsed frequency of 3 images per second. The single images were merged and reconstructed to one image with the software easy spine (Philips medical Systems, Eindhoven, The Netherlands). The corresponding dose-area product values (DAP) of both methods were compared. Three independent observers assessed Cobb angles and image quality for each technique. Results: the mean DAP values for conventional imaging was 94.9 cGy x cm{sup 2} and for fluoroscopy 7.8 cGy x cm{sup 2}, respectively. A significant dose reduction of 91.8% (CI 91% to 95%) was calculated. The average absolute angle difference between the observers was found to be 2.7 for conventional imaging and 2.4 for the fluoroscopic method. Interobserver standard deviation of 2.9 was lower than the 5.3 for conventional images. Image quality was better in the conventional images. Conclusion: using the scanning method, we could achieve a mean reduction of the radiation dose of 92%, while the accuracy of the Cobb angle measurements was comparable for both techniques despite of reduced image quality of digital fluoroscopy. (orig.)

  15. Measuring serotonin synthesis: from conventional methods to PET tracers and their (pre)clinical implications

    Energy Technology Data Exchange (ETDEWEB)

    Visser, Anniek K.D.; Waarde, Aren van; Willemsen, Antoon T.M. [University of Groningen, University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Bosker, Fokko J. [University of Groningen, University Medical Center Groningen, University Center of Psychiatry, Groningen (Netherlands); Luiten, Paul G.M. [University of Groningen, Center for Behavior and Neurosciences, Department of Molecular Neurobiology, Haren (Netherlands); Boer, Johan A. den [University of Groningen, University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University of Groningen, University Medical Center Groningen, University Center of Psychiatry, Groningen (Netherlands); Kema, Ido P. [University of Groningen, University Medical Center Groningen, Department of Laboratory Medicine, Groningen (Netherlands); Dierckx, Rudi A.J.O. [University of Groningen, University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Hospital Ghent, Department of Nuclear Medicine, Ghent (Belgium)

    2011-03-15

    The serotonergic system of the brain is complex, with an extensive innervation pattern covering all brain regions and endowed with at least 15 different receptors (each with their particular distribution patterns), specific reuptake mechanisms and synthetic processes. Many aspects of the functioning of the serotonergic system are still unclear, partially because of the difficulty of measuring physiological processes in the living brain. In this review we give an overview of the conventional methods of measuring serotonin synthesis and methods using positron emission tomography (PET) tracers, more specifically with respect to serotonergic function in affective disorders. Conventional methods are invasive and do not directly measure synthesis rates. Although they may give insight into turnover rates, a more direct measurement may be preferred. PET is a noninvasive technique which can trace metabolic processes, like serotonin synthesis. Tracers developed for this purpose are {alpha}-[{sup 11}C]methyltryptophan ([{sup 11}C]AMT) and 5-hydroxy-L-[{beta}-{sup 11}C]tryptophan ([{sup 11}C]5-HTP). Both tracers have advantages and disadvantages. [{sup 11}C]AMT can enter the kynurenine pathway under inflammatory conditions (and thus provide a false signal), but this tracer has been used in many studies leading to novel insights regarding antidepressant action. [{sup 11}C]5-HTP is difficult to produce, but trapping of this compound may better represent serotonin synthesis. AMT and 5-HTP kinetics are differently affected by tryptophan depletion and changes of mood. This may indicate that both tracers are associated with different enzymatic processes. In conclusion, PET with radiolabelled substrates for the serotonergic pathway is the only direct way to detect changes of serotonin synthesis in the living brain. (orig.)

  16. A combination of small bowel imaging methods: conventional enteroclysis with complementary magnetic resonance enteroclysis

    Energy Technology Data Exchange (ETDEWEB)

    Akman, C. [Department of Radiology, Cerrahpasa Medical Faculty, Istanbul University, Istanbul (Turkey); Korman, U. [Department of Radiology, Cerrahpasa Medical Faculty, Istanbul University, Istanbul (Turkey)]. E-mail: ugurk9@istanbul.edu.tr; Oguet, G. [Department of Radiology, Cerrahpasa Medical Faculty, Istanbul University, Istanbul (Turkey); Kurugoglu, S. [Department of Radiology, Cerrahpasa Medical Faculty, Istanbul University, Istanbul (Turkey); Urger, E. [Department of Radiology, Cerrahpasa Medical Faculty, Istanbul University, Istanbul (Turkey); Ulus, S. [Department of Radiology, Cerrahpasa Medical Faculty, Istanbul University, Istanbul (Turkey); Esen, G. [Department of Radiology, Cerrahpasa Medical Faculty, Istanbul University, Istanbul (Turkey); Tasci, I. [Department of Surgery, Cerrahpasa Medical Faculty, Istanbul University, Istanbul (Turkey)

    2005-07-01

    AIM: The aim of this prospective study was to evaluate the overall findings of conventional enteroclysis (CE) with complementary magnetic resonance enteroclysis (MRE) in small bowel disease. METHODS: The study included 32 patients referred from various clinical departments, with known or suspected small bowel disease and abnormalities on CE. Immediately after CE, true fast imaging with steady-state precession (true FISP), and unenhanced and gadolinium-enhanced T1-weighted fast low-angle shot (FLASH) sequences with fat saturation were obtained. Mucosal, mural and luminal changes of the small bowel were evaluated by each technique. In addition, bowel wall thickening, bowel wall enhancement and perienteric changes were assessed by MRE. The radiological findings obtained were evaluated together as a combination, and the role of MRE in the determination of the activity and complications of the small bowel disease was assessed. Radiological findings were correlated with clinical evaluation and follow-up in all cases, including endoscopy in 14 cases and surgery in 5 cases. RESULTS: MRE provided important supplementary mural and extramural information, including degree of pathological wall thickness, mural enhancement pattern associated with disease activity, perivisceral collection, abscess formation, mesenteric fibrofatty proliferation, lymphadenopathy and increase in perienteric vascularity. Short strictures were not revealed on MRE; however, for patients with a history of abdominal malignancy, MRE helped characterize the level of any obstruction and the extent of the disease. CONCLUSION: We recommend MRE for patients who have findings of advanced inflammatory bowel disease or neoplasm on CE examination. The combination of these two techniques can provide important information on the degree and extent of the disorder.

  17. Guidelines for the verification and validation of expert system software and conventional software: Survey and assessment of conventional software verification and validation methods. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Mirsky, S.M.; Groundwater, E.H.; Hayes, J.E.; Miller, L.A. [Science Applications International Corp., McLean, VA (United States)

    1995-03-01

    By means of a literature survey, a comprehensive set of methods was identified for the verification and validation of conventional software. The 153 methods so identified were classified according to their appropriateness for various phases of a developmental life-cycle -- requirements, design, and implementation; the last category was subdivided into two, static testing and dynamic testing methods. The methods were then characterized in terms of eight rating factors, four concerning ease-of-use of the methods and four concerning the methods` power to detect defects. Based on these factors, two measurements were developed to permit quantitative comparisons among methods, a Cost-Benefit metric and an Effectiveness Metric. The Effectiveness Metric was further refined to provide three different estimates for each method, depending on three classes of needed stringency of V&V (determined by ratings of a system`s complexity and required-integrity). Methods were then rank-ordered for each of the three classes by terms of their overall cost-benefits and effectiveness. The applicability was then assessed of each for the identified components of knowledge-based and expert systems, as well as the system as a whole.

  18. Guidelines for the verification and validation of expert system software and conventional software: Survey and assessment of conventional software verification and validation methods. Volume 2

    International Nuclear Information System (INIS)

    Mirsky, S.M.; Groundwater, E.H.; Hayes, J.E.; Miller, L.A.

    1995-03-01

    By means of a literature survey, a comprehensive set of methods was identified for the verification and validation of conventional software. The 153 methods so identified were classified according to their appropriateness for various phases of a developmental life-cycle -- requirements, design, and implementation; the last category was subdivided into two, static testing and dynamic testing methods. The methods were then characterized in terms of eight rating factors, four concerning ease-of-use of the methods and four concerning the methods' power to detect defects. Based on these factors, two measurements were developed to permit quantitative comparisons among methods, a Cost-Benefit metric and an Effectiveness Metric. The Effectiveness Metric was further refined to provide three different estimates for each method, depending on three classes of needed stringency of V ampersand V (determined by ratings of a system's complexity and required-integrity). Methods were then rank-ordered for each of the three classes by terms of their overall cost-benefits and effectiveness. The applicability was then assessed of each for the identified components of knowledge-based and expert systems, as well as the system as a whole

  19. Membrane for distillation including nanostructures, methods of making membranes, and methods of desalination and separation

    KAUST Repository

    Lai, Zhiping; Huang, Kuo-Wei; Chen, Wei

    2016-01-01

    In accordance with the purpose(s) of the present disclosure, as embodied and broadly described herein, embodiments of the present disclosure provide membranes, methods of making the membrane, systems including the membrane, methods of separation, methods of desalination, and the like.

  20. Membrane for distillation including nanostructures, methods of making membranes, and methods of desalination and separation

    KAUST Repository

    Lai, Zhiping

    2016-01-21

    In accordance with the purpose(s) of the present disclosure, as embodied and broadly described herein, embodiments of the present disclosure provide membranes, methods of making the membrane, systems including the membrane, methods of separation, methods of desalination, and the like.

  1. Consumer acceptance and aroma characterization of navy bean (Phaseolus vulgaris) powders prepared by extrusion and conventional processing methods.

    Science.gov (United States)

    Szczygiel, Edward J; Harte, Janice B; Strasburg, Gale M; Cho, Sungeun

    2017-09-01

    Food products produced with bean ingredients are gaining in popularity among consumers due to the reported health benefits. Navy bean (Phaseolus vulgaris) powder produced through extrusion can be considered as a resource-efficient alternative to conventional methods, which often involve high water inputs. Therefore, navy bean powders produced with extrusion and conventional methods were assessed for the impact of processing on consumer liking in end-use products and odor-active compounds. Consumer acceptance results reveal significant differences in flavor, texture and overall acceptance scores of several products produced with navy bean powder. Crackers produced with extruded navy bean powder received higher hedonic flavor ratings than those produced with commercial navy bean powder (P < 0.001). GC-O data showed that the commercial powder produced through conventional processing had much greater contents of several aliphatic aldehydes commonly formed via lipid oxidation, such as hexanal, octanal and nonanal with descriptors of 'grassy', 'nutty', 'fruity', 'dusty', and 'cleaner', compared to the extruded powder. Extrusion processed navy bean powders were preferred over commercial powders for certain navy bean powder applications. This is best explained by substantial differences in aroma profiles of the two powders that may have been caused by lipid oxidation. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  2. A comparison of methods for demonstrating artificial bone lesions; conventional versus computer tomography

    International Nuclear Information System (INIS)

    Heller, M.; Wenk, M.; Jend, H.H.

    1984-01-01

    Conventional tomography (T) and computer tomography (CT) were used for examining 97 artificial bone lesions at various sites. The purpose of the study was to determine how far CT can replace T in the diagnosis of skeletal abnormalities. The results have shown that modern CT, particularly in its high resolution form, equals T and provides additional information (substrate of a lesion, its relationship to neighbouring tissues, simultaneous demonstration of soft tissue etc.). These cannot be shown successfully by T. It follows that CT is indicated as the primary method of examination for lesions of the facial skeleton, skull base, spine, pelvis and, to some extent, extremities. (orig.) [de

  3. Isolation and Identification of Campylobacter spp. from Poultry and Poultry By-Products in Tunisia by Conventional Culture Method and Multiplex Real-Time PCR.

    Science.gov (United States)

    Jribi, Hela; Sellami, Hanen; Mariam, Siala; Smaoui, Salma; Ghorbel, Asma; Hachicha, Salma; Benejat, Lucie; Messadi-Akrout, Feriel; Mégraud, Francis; Gdoura, Radhouane

    2017-10-01

    Thermophilic Campylobacter spp. are one of the primary causes of bacterial human diarrhea. The consumption of poultry meats, by-products, or both is suspected to be a major cause of human campylobacteriosis. The aims of this study were to determine the prevalence of thermophilic Campylobacter spp. in fresh poultry meat and poultry by-products by conventional culture methods and to confirm Campylobacter jejuni and Campylobacter coli isolates by using the multiplex PCR assay. Two hundred fifty fresh poultry samples were collected from a variety of supermarkets and slaughterhouses located in Sfax, Tunisia, including chicken (n =149) and turkey (n =101). The samples were analyzed using conventional microbiological examinations according to the 2006 International Organization for Standardization method (ISO 10272-1) for Campylobacter spp. Concurrently, a real-time PCR was used for identification of C. jejuni and C. coli . Of the 250 samples of poultry meat and poultry by-products, 25.6% (n = 64) were contaminated with Campylobacter spp. The highest prevalence of Campylobacter spp. was found in chicken meat (26.8%) followed by turkey meat (23.7%). Among the different products, poultry breasts showed the highest contamination (36.6%) followed by poultry by-products (30%), poultry wings (28%) and poultry legs (26%) showed the lowest contamination, and no contamination was found on neck skin. Of the 64 thermophilic Campylobacter isolates, C. jejuni (59.7%) was the most frequently isolated species and 10.9% of the isolates were identified as C. coli . All of the 64 Campylobacter isolates identified by the conventional culture methods were further confirmed by PCR. The seasonal peak of Campylobacter spp. contamination was in the warm seasons (spring and summer). The study concluded that high proportions of poultry meat and poultry by-products marketed in Tunisia are contaminated by Campylobacter spp. Furthermore, to ensure food safety, poultry meats must be properly cooked

  4. Maxillary incisors changes during space closure with conventional and skeletal anchorage methods: a systematic review.

    Science.gov (United States)

    Jayaratne, Yasas Shri Nalaka; Uribe, Flavio; Janakiraman, Nandakumar

    2017-01-01

    The objective of this systematic review was to compare the antero-posterior, vertical and angular changes of maxillary incisors with conventional anchorage control techniques and mini-implant based space closure methods. The electronic databases Pubmed, Scopus, ISI Web of knowledge, Cochrane Library and Open Grey were searched for potentially eligible studies using a set of predetermined keywords. Full texts meeting the inclusion criteria as well as their references were manually searched. The primary outcome data (linear, angular, and vertical maxillary incisor changes) and secondary outcome data (overbite changes, soft tissue changes, biomechanical factors, root resorption and treatment duration) were extracted from the selected articles and entered into spreadsheets based on the type of anchorage used. The methodological quality of each study was assessed. Six studies met the inclusion criteria. The amount of incisor retraction was greater with buccally placed mini-implants than conventional anchorage techniques. The incisor retraction with indirect anchorage from palatal mini-implants was less when compared with buccally placed mini-implants. Incisor intrusion occurred with buccal mini-implants, whereas extrusion was seen with conventional anchorage. Limited data on the biomechanical variables or adverse effects such as root resorption were reported in these studies. More RCT's that take in to account relevant biomechanical variables and employ three-dimensional quantification of tooth movements are required to provide information on incisor changes during space closure.

  5. Reinforcing the role of the conventional C-arm--a novel method for simplified distal interlocking.

    Science.gov (United States)

    Windolf, Markus; Schroeder, Josh; Fliri, Ladina; Dicht, Benno; Liebergall, Meir; Richards, R Geoff

    2012-01-25

    shot to screw tightened) was on average 22% reduced by guided freehand (p = 0.018). In an experimental setting, the newly developed guided freehand technique for distal interlocking has proven to markedly reduce radiation exposure when compared to the conventional freehand technique. The method utilizes established clinical workflows and does not require cost intensive add-on devices or extensive training. The underlying principle carries potential to assist implant positioning in numerous other applications within orthopedics and trauma from screw insertions to placement of plates, nails or prostheses.

  6. 9th Structural Engineering Convention 2014

    CERN Document Server

    2015-01-01

    The book presents research papers presented by academicians, researchers, and practicing structural engineers from India and abroad in the recently held Structural Engineering Convention (SEC) 2014 at Indian Institute of Technology Delhi during 22 – 24 December 2014. The book is divided into three volumes and encompasses multidisciplinary areas within structural engineering, such as earthquake engineering and structural dynamics, structural mechanics, finite element methods, structural vibration control, advanced cementitious and composite materials, bridge engineering, and soil-structure interaction. Advances in Structural Engineering is a useful reference material for structural engineering fraternity including undergraduate and postgraduate students, academicians, researchers and practicing engineers.

  7. Toxoplasmosis: The value of molecular methods in diagnosis compared to conventional methods

    Directory of Open Access Journals (Sweden)

    Zineb Tlamçani

    2013-06-01

    Full Text Available Toxoplasmosis is a parasitic infection due to Toxoplasma gondii an obligate intracellular protozoan parasite. It is considerateone of the most common parasite worldwide. The contamination of the parasite is generally occurred via consumptionof infected food or water or, undercooked contaminated meat. Toxoplasma gondii infection may lead to seriousillness when the organism is contracted while pregnancy or when it is reactivated in immune-suppressed persons.Diagnosis of toxoplasmosis in humans is elaborated using various techniques such as detection of anti-Toxoplasmaantibodies, mouse inoculation, histological revelation of tachyzoites in tissue sections or smears of body fluid, but thedetection of Toxoplasma gondii DNA by molecular methods has revolutionized prenatal diagnosis of congenital toxoplasmosisand in immunocompromised patients. In this paper we will discuss the parasite and different methods ofdiagnosis including the usefulness of molecular methods. J Microbiol Infect Dis 2013; 3(2: 93-99Key words: Toxoplamosis, Toxoplasma gondii, diagnosis

  8. Clinical target volume localization using conventional methods (anatomy and palpation) and ultrasonography in early breast cancer post-operative external irradiation

    International Nuclear Information System (INIS)

    Valdagni, Riccardo; Italia, Corrado; Montanaro, Paolo; Ciocca, Mario; Morandi, Giovanni; Salvadori, Bruno

    1997-01-01

    %, respectively (P = 0.02). Also, in the subgroup of pre-menopausal patients the CTV defined by palpatory reference lines appeared to be more accurate than A-method (P < 0.01). Conclusions: Conventional methods frequently appear inadequate to localize residual mammary gland in EBC post-operative external irradiation. This analysis evidentiates the inaccuracy of empirical CTV definition, and suggests that palpation or anatomical reference borders should be critically used and that state of art imaging methods should be included in treatment planning, particularly in pre-menopausal pts. If economical or individual variables have to be taken into account, palpation might be considered in post-menopausal women

  9. A consistent response spectrum analysis including the resonance range

    International Nuclear Information System (INIS)

    Schmitz, D.; Simmchen, A.

    1983-01-01

    The report provides a complete consistent Response Spectrum Analysis for any component. The effect of supports with different excitation is taken into consideration, at is the description of the resonance ranges. It includes information explaining how the contributions of the eigenforms with higher eigenfrequencies are to be considered. Stocking of floor response spectra is also possible using the method described here. However, modified floor response spectra must now be calculated for each building mode. Once these have been prepared, the calculation of the dynamic component values is practically no more complicated than with the conventional, non-consistent methods. The consistent Response Spectrum Analysis can supply smaller and larger values than the conventional theory, a fact which can be demonstrated using simple examples. The report contains a consistent Response Spectrum Analysis (RSA), which, as far as we know, has been formulated in this way for the first time. A consistent RSA is so important because today this method is preferentially applied as an important tool for the earthquake proof of components in nuclear power plants. (orig./HP)

  10. Conventional laboratory methods for cyanotoxins.

    Science.gov (United States)

    Lawton, Linda A; Edwards, C

    2008-01-01

    It is clear from the literature that numerous methods are available for most cyanotoxins, although many publications on monitoring data indicate that the favored approach is the use proven, robust methods for individual toxins. The most effective approach is the utilization of a robust rapid screen, where positive samples are followed up by qualitative and quantitative analysis to provide the essential decision making data needed for successful management strategies (Fig. 2). Currently, rapid screens are available for microcystins, saxitoxins and anatoxin-a(s), whilst optimisation and validation is needed, many publications report good correlation with the mouse bioassay and HPLC. There is an urgent need for rapid, simple, and inexpensive assays for cylindrospermopsins, anatoxin-a and BMAA. Although methods exist for analysis of BMAA, the fact that a recent study showed 95% of cyanobacteria producing this, some at levels > 6,000 microg g(-1) dry wt, is of concern and rapid screening followed by robust analysis needed. An ideal approach would be a single method capable of extracting and detecting all cyanotoxins. Several publications describe such approaches using LC-MS, but as expected from a group of compounds with diverse chemistry, there are obvious limitations in recoveries during sample processing, chromatographic performance and sensitivity (Dahlmann et al. 2003, Dell'Aversano et al. 2004, Pietsch et al. 2001). Selection of methods must be based on the application requirements, equipment available and cost. For many organisations it may be more cost effective to out-source the occasional analysis. However, as the incidence of blooms appears to be increasing, the need for more rigorous monitoring is needed, sensible investment is needed to meet recommended guidelines. Most of the methods discussed in this paper are suitable for achieving this goal, although clean-up and concentration is usually necessary for physicochemical methods.

  11. Evaluation of osteoporosis using conventional radiographic methods and dual energy x-ray absorptiometry

    International Nuclear Information System (INIS)

    Anburajan, M.

    2001-01-01

    In India, conventional radiographs play a major part in evaluating osteoporosis since advanced bone densitometers are expensive and not widely available. Our aim in this study was to investigate the usefulness of conventional radiographic methods, viz., clavicle and metacarpal radiogrammetry, quantitative vertebral morphometry, Singh's index, hip geometry compared to a sophisticated method, viz., DXA for studying osteoporosis in south Indian men (n=663) and women (n=741). This study provides data on BMD of the proximal femur in normal south Indian females. In women, aged above 65 years, BMD of femoral neck, trochanter, and Ward's triangle decreased by 0.90%, 0.84%, and 1.66% per annum, respectively. In 45 pre- and post-menopausal women without fractures, total hip BMD correlated significantly ( p 2 =0.47), medial cortical thickness of the femoral shaft (r 2 =0.38) and neck (r 2 =0.29), combined cortical thickness (CCT) and %CCT of the clavicle (r 2 =0.54 each), and the second metacarpal (r 2 =0.51 and r 2 =0.53, respectively). On comparing variables studied for osteoporotic women with corresponding values in the premenopausal group, the average difference in SD from the mean was greatest for clavicle radiogrammetry (-3.7 SD for %CCT of the clavicle). An empirical formula for predicting total hip BMD with good sensitivity was derived from a multiple linear regression equation involving three independent variables, viz., CCT, %CCT of the clavicle (measured from the chest radiograph) and the patient's age. This author's equation, with modified weightings, has 82% sensitivity and 94% specificity and a positive and negative predictive value of 88% and 91% respectively. A chest radiograph in combination with the formula would serve as a readily available, inexpensive tool for assessing post-menopausal osteoporosis, especially in developing countries

  12. Minamata Convention on Mercury. Reporting obligations of the Parties to the Convention and the sources of data existing in Poland

    Directory of Open Access Journals (Sweden)

    Strzelecka-Jastrząb Ewa

    2018-01-01

    Full Text Available After that, when more than 60 years ago in the Japanese city of Minamata there was caused a mass poisoning of residents by seafood contaminated with mercury, Minamata Convention on Mercury came into force on August 16, 2017. To date, the Convention has been signed by 128 States, the signatories of the Convention and ratified by 83 States - Parties to the Convention. The Convention imposes a number of obligations on the Parties to the Convention, including the reporting obligation. The paper analyses the reporting obligations of the Parties to the Convention, which are in force after the entry into force of the Convention, pursuant to the provisions contained therein. In addition, the existing sources of quantitative data on mercury in Poland are characterized.

  13. Effect of amaranth dye on the growth and properties of conventional and SR method grown KAP single crystals

    Science.gov (United States)

    Babu Rao, G.; P., Rajesh; Ramasamy, P.

    2018-04-01

    The 0.1 mol% amaranth added KAP single crystals were grown from aqueous solutions by both slow evaporation solution technique and Sankaranarayanan-Ramasamy method. The single crystal having dimension of 45 mm length and 12 mm diameter was grown with growth rate of 1.5 mm/day using SR method. 87 % transmittance is obtained for SR method grown amaranth added KAP single crystal. The high intense luminescence at 661 nm is obtained from amaranth added conventional and SR method grown KAP single crystal. The amaranth added KAP single crystal possesses good mechanical and laser damage threshold stability.

  14. Comparison of a radiometric method (BACTEC) and conventional culture media for recovery of mycobacteria from smear-negative specimens

    International Nuclear Information System (INIS)

    Morgan, M.A.; Horstmeier, C.D.; DeYoung, D.R.; Roberts, G.D.

    1983-01-01

    The BACTEC system and three conventional media (Middlebrook 7H10, selective Middlebrook 7H11 [S7H11], and Lowenstein-Jensen [LJ] were compared for their mean recovery times and recovery rates of mycobacteria from acid-fast, smear-negative clinical specimens. Of the 71 smear-negative, culture-positive specimens recovered from 2,165 submitted smear-negative cultures, the BACTEC system detected 71.8%, compared with 88.7% for the conventional three-medium system. When media were individually compared, BACTEC medium (Middlebrook 7H12) was more successful in recovering mycobacteria (71.8%) than was LJ (62%), Middlebrook medium 7H10 (55.9%), or Middlebrook S7H11 medium (52.1%). Middlebrook 7H11 medium containing sodium selenate was also evaluated and did not increase the recovery rate or decrease the recovery time of mycobacterial species when compared with LJ, Middlebrook 7H10, S7H11, and 7H12 media. The mean detection time for the BACTEC system was less than that by conventional methods for the seven species of mycobacteria recovered. Detection times for Mycobacterium tuberculosis on the BACTEC system and conventional cultural systems were 13.7 and 26.3 days, respectively

  15. Familiarity Vs Trust: A Comparative Study of Domain Scientists' Trust in Visual Analytics and Conventional Analysis Methods.

    Science.gov (United States)

    Dasgupta, Aritra; Lee, Joon-Yong; Wilson, Ryan; Lafrance, Robert A; Cramer, Nick; Cook, Kristin; Payne, Samuel

    2017-01-01

    Combining interactive visualization with automated analytical methods like statistics and data mining facilitates data-driven discovery. These visual analytic methods are beginning to be instantiated within mixed-initiative systems, where humans and machines collaboratively influence evidence-gathering and decision-making. But an open research question is that, when domain experts analyze their data, can they completely trust the outputs and operations on the machine-side? Visualization potentially leads to a transparent analysis process, but do domain experts always trust what they see? To address these questions, we present results from the design and evaluation of a mixed-initiative, visual analytics system for biologists, focusing on analyzing the relationships between familiarity of an analysis medium and domain experts' trust. We propose a trust-augmented design of the visual analytics system, that explicitly takes into account domain-specific tasks, conventions, and preferences. For evaluating the system, we present the results of a controlled user study with 34 biologists where we compare the variation of the level of trust across conventional and visual analytic mediums and explore the influence of familiarity and task complexity on trust. We find that despite being unfamiliar with a visual analytic medium, scientists seem to have an average level of trust that is comparable with the same in conventional analysis medium. In fact, for complex sense-making tasks, we find that the visual analytic system is able to inspire greater trust than other mediums. We summarize the implications of our findings with directions for future research on trustworthiness of visual analytic systems.

  16. Dosimetry comparison of pelvimetry methods using conventional radiographs and CT

    International Nuclear Information System (INIS)

    Resten, A.; Suissa, M.; Musset, D.; Mausoleo, F.; Valero, M.; Taylor, S.

    2001-01-01

    To determine the fetal and maternal exposure to radiation by use of thermoluminescent dosimeters in order to compare conventional and CT-scan X-ray. Dosimetry was performed with an anthropomorph phantom. Thermoluminescent dosimeters were positioned on the surface and in the depth of the phantom. Digital radiography of the pelvis was performed according to a standard technique. CT-scan of the pelvis was performed according to the Buthiau's technique. With CT, the dose reached 0.31 to 4.95 mGy, with a dose of 2.32 mGy for the fetal gonads. With standard technique, the doses reached 0.03 to 0.39 mGy, with a dose of 0.39 mGy for the fetal gonads. With CT the fetus and the mother were exposed to 1/10. of the total dose delivered using conventional X-rays and the dose distribution was more homogeneous. (author)

  17. Digital Versus Conventional Impressions in Fixed Prosthodontics: A Review.

    Science.gov (United States)

    Ahlholm, Pekka; Sipilä, Kirsi; Vallittu, Pekka; Jakonen, Minna; Kotiranta, Ulla

    2018-01-01

    To conduct a systematic review to evaluate the evidence of possible benefits and accuracy of digital impression techniques vs. conventional impression techniques. Reports of digital impression techniques versus conventional impression techniques were systematically searched for in the following databases: Cochrane Central Register of Controlled Trials, PubMed, and Web of Science. A combination of controlled vocabulary, free-text words, and well-defined inclusion and exclusion criteria guided the search. Digital impression accuracy is at the same level as conventional impression methods in fabrication of crowns and short fixed dental prostheses (FDPs). For fabrication of implant-supported crowns and FDPs, digital impression accuracy is clinically acceptable. In full-arch impressions, conventional impression methods resulted in better accuracy compared to digital impressions. Digital impression techniques are a clinically acceptable alternative to conventional impression methods in fabrication of crowns and short FDPs. For fabrication of implant-supported crowns and FDPs, digital impression systems also result in clinically acceptable fit. Digital impression techniques are faster and can shorten the operation time. Based on this study, the conventional impression technique is still recommended for full-arch impressions. © 2016 by the American College of Prosthodontists.

  18. Antiseptic Effect of Conventional Povidone-Iodine Scrub, Chlorhexidine Scrub, and Waterless Hand Rub in a Surgical Room: A Randomized Controlled Trial.

    Science.gov (United States)

    Tsai, Jui-Chen; Lin, Yen-Kuang; Huang, Yen-Jung; Loh, El-Wui; Wen, Hsiao-Yun; Wang, Chia-Hui; Tsai, Yin-Tai; Hsieh, Wen-Shyang; Tam, Ka-Wai

    2017-04-01

    OBJECTIVE Effective perioperative hand antisepsis is crucial for the safety of patients and medical staff in surgical rooms. The antimicrobial effectiveness of different antiseptic methods, including conventional hand scrubs and waterless hand rubs, has not been well evaluated. DESIGN, SETTING, AND PARTICIPANTS A randomized controlled trial was conducted to investigate the effectiveness of the 3 antiseptic methods among surgical staff of Taipei Medical University-Shuang Ho Hospital. For each method used, a group of 80 participants was enrolled. INTERVENTION Surgical hand cleansing with conventional 10% povidone-iodine scrub, conventional 4% chlorhexidine scrub, or waterless hand rub (1% chlorhexidine gluconate and 61% ethyl alcohol). RESULTS Colony-forming unit (CFU) counts were collected using the hand imprinting method before and after disinfection and after surgery. After surgical hand disinfection, the mean CFU counts of the conventional chlorhexidine (0.5±0.2, Pantiseptic method (P=.0036), but not other variables, predicted the mean CFU count. CONCLUSIONS Conventional chlorhexidine scrub and waterless hand rub were superior to a conventional povidone-iodine product in bacterial inhibition. We recommend using conventional chlorhexidine scrub as a standard method for perioperative hand antisepsis. Waterless hand rub may be used if the higher cost is affordable. Infect Control Hosp Epidemiol 2017;38:417-422.

  19. Methods for Equating Mental Tests.

    Science.gov (United States)

    1984-11-01

    1983) compared conventional and IRT methods for equating the Test of English as a Foreign Language ( TOEFL ) after chaining. Three conventional and...three IRT equating methods were examined in this study; two sections of TOEFL were each (separately) equated. The IRT methods included the following: (a...group. A separate base form was established for each of the six equating methods. Instead of equating the base-form TOEFL to itself, the last (eighth

  20. Unsteady panel method for complex configurations including wake modeling

    CSIR Research Space (South Africa)

    Van Zyl, Lourens H

    2008-01-01

    Full Text Available implementations of the DLM are however not very versatile in terms of geometries that can be modeled. The ZONA6 code offers a versatile surface panel body model including a separated wake model, but uses a pressure panel method for lifting surfaces. This paper...

  1. Comparison of the Microbiological Quality and Safety between Conventional and Organic Vegetables Sold in Malaysia

    Directory of Open Access Journals (Sweden)

    Chee-Hao Kuan

    2017-07-01

    Full Text Available Given the remarkable increase of public interest in organic food products, it is indeed critical to evaluate the microbiological risk associated with consumption of fresh organic produce. Organic farming practices including the use of animal manures may increase the risk of microbiological contamination as manure can act as a vehicle for transmission of foodborne pathogens. This study aimed to determine and compare the microbiological status between organic and conventional fresh produce at the retail level in Malaysia. A total of 152 organic and conventional vegetables were purchased at retail markets in Malaysia. Samples were analyzed for mesophilic aerobic bacteria, yeasts and molds, and total coliforms using conventional microbiological methods. Combination methods of most probable number-multiplex polymerase chain reaction (MPN-mPCR were used to detect and quantify foodborne pathogens, including Escherichia coli O157:H7, Shiga toxin-producing E. coli (STEC, Listeria monocytogenes, Salmonella Typhimurium, and Salmonella Enteritidis. Results indicated that most types of organic and conventional vegetables possessed similar microbial count (P > 0.05 of mesophilic aerobic bacteria, yeasts and molds, and total coliforms. E. coli O157:H7 and S. Typhimurium were not detected in any sample analyzed in this study. Among the 152 samples tested, only the conventional lettuce and organic carrot were tested positive for STEC and S. Enteritidis, respectively. L. monocytogenes were more frequently detected in both organic (9.1% and conventional vegetables (2.7% as compared to E. coli O157:H7, S. Typhimurium, and S. Enteritidis. Overall, no trend was shown that either organically or conventionally grown vegetables have posed greater microbiological risks. These findings indicated that one particular type of farming practices would not affect the microbiological profiles of fresh produce. Therefore, regardless of farming methods, all vegetables should be

  2. Comparison of the Microbiological Quality and Safety between Conventional and Organic Vegetables Sold in Malaysia.

    Science.gov (United States)

    Kuan, Chee-Hao; Rukayadi, Yaya; Ahmad, Siti H; Wan Mohamed Radzi, Che W J; Thung, Tze-Young; Premarathne, Jayasekara M K J K; Chang, Wei-San; Loo, Yuet-Ying; Tan, Chia-Wanq; Ramzi, Othman B; Mohd Fadzil, Siti N; Kuan, Chee-Sian; Yeo, Siok-Koon; Nishibuchi, Mitsuaki; Radu, Son

    2017-01-01

    Given the remarkable increase of public interest in organic food products, it is indeed critical to evaluate the microbiological risk associated with consumption of fresh organic produce. Organic farming practices including the use of animal manures may increase the risk of microbiological contamination as manure can act as a vehicle for transmission of foodborne pathogens. This study aimed to determine and compare the microbiological status between organic and conventional fresh produce at the retail level in Malaysia. A total of 152 organic and conventional vegetables were purchased at retail markets in Malaysia. Samples were analyzed for mesophilic aerobic bacteria, yeasts and molds, and total coliforms using conventional microbiological methods. Combination methods of most probable number-multiplex polymerase chain reaction (MPN-mPCR) were used to detect and quantify foodborne pathogens, including Escherichia coli O157:H7, Shiga toxin-producing E. coli (STEC), Listeria monocytogenes, Salmonella Typhimurium, and Salmonella Enteritidis. Results indicated that most types of organic and conventional vegetables possessed similar microbial count ( P > 0.05) of mesophilic aerobic bacteria, yeasts and molds, and total coliforms. E. coli O157:H7 and S . Typhimurium were not detected in any sample analyzed in this study. Among the 152 samples tested, only the conventional lettuce and organic carrot were tested positive for STEC and S . Enteritidis, respectively. L. monocytogenes were more frequently detected in both organic (9.1%) and conventional vegetables (2.7%) as compared to E. coli O157:H7, S . Typhimurium, and S . Enteritidis. Overall, no trend was shown that either organically or conventionally grown vegetables have posed greater microbiological risks. These findings indicated that one particular type of farming practices would not affect the microbiological profiles of fresh produce. Therefore, regardless of farming methods, all vegetables should be subjected to

  3. Comparison of the Microbiological Quality and Safety between Conventional and Organic Vegetables Sold in Malaysia

    Science.gov (United States)

    Kuan, Chee-Hao; Rukayadi, Yaya; Ahmad, Siti H.; Wan Mohamed Radzi, Che W. J.; Thung, Tze-Young; Premarathne, Jayasekara M. K. J. K.; Chang, Wei-San; Loo, Yuet-Ying; Tan, Chia-Wanq; Ramzi, Othman B.; Mohd Fadzil, Siti N.; Kuan, Chee-Sian; Yeo, Siok-Koon; Nishibuchi, Mitsuaki; Radu, Son

    2017-01-01

    Given the remarkable increase of public interest in organic food products, it is indeed critical to evaluate the microbiological risk associated with consumption of fresh organic produce. Organic farming practices including the use of animal manures may increase the risk of microbiological contamination as manure can act as a vehicle for transmission of foodborne pathogens. This study aimed to determine and compare the microbiological status between organic and conventional fresh produce at the retail level in Malaysia. A total of 152 organic and conventional vegetables were purchased at retail markets in Malaysia. Samples were analyzed for mesophilic aerobic bacteria, yeasts and molds, and total coliforms using conventional microbiological methods. Combination methods of most probable number-multiplex polymerase chain reaction (MPN-mPCR) were used to detect and quantify foodborne pathogens, including Escherichia coli O157:H7, Shiga toxin-producing E. coli (STEC), Listeria monocytogenes, Salmonella Typhimurium, and Salmonella Enteritidis. Results indicated that most types of organic and conventional vegetables possessed similar microbial count (P > 0.05) of mesophilic aerobic bacteria, yeasts and molds, and total coliforms. E. coli O157:H7 and S. Typhimurium were not detected in any sample analyzed in this study. Among the 152 samples tested, only the conventional lettuce and organic carrot were tested positive for STEC and S. Enteritidis, respectively. L. monocytogenes were more frequently detected in both organic (9.1%) and conventional vegetables (2.7%) as compared to E. coli O157:H7, S. Typhimurium, and S. Enteritidis. Overall, no trend was shown that either organically or conventionally grown vegetables have posed greater microbiological risks. These findings indicated that one particular type of farming practices would not affect the microbiological profiles of fresh produce. Therefore, regardless of farming methods, all vegetables should be subjected to

  4. Evaluation of purity with its uncertainty value in high purity lead stick by conventional and electro-gravimetric methods.

    Science.gov (United States)

    Singh, Nahar; Singh, Niranjan; Tripathy, S Swarupa; Soni, Daya; Singh, Khem; Gupta, Prabhat K

    2013-06-26

    A conventional gravimetry and electro-gravimetry study has been carried out for the precise and accurate purity determination of lead (Pb) in high purity lead stick and for preparation of reference standard. Reference materials are standards containing a known amount of an analyte and provide a reference value to determine unknown concentrations or to calibrate analytical instruments. A stock solution of approximate 2 kg has been prepared after dissolving approximate 2 g of Pb stick in 5% ultra pure nitric acid. From the stock solution five replicates of approximate 50 g have been taken for determination of purity by each method. The Pb has been determined as PbSO4 by conventional gravimetry, as PbO2 by electro gravimetry. The percentage purity of the metallic Pb was calculated accordingly from PbSO4 and PbO2. On the basis of experimental observations it has been concluded that by conventional gravimetry and electro-gravimetry the purity of Pb was found to be 99.98 ± 0.24 and 99.97 ± 0.27 g/100 g and on the basis of Pb purity the concentration of reference standard solutions were found to be 1000.88 ± 2.44 and 1000.81 ± 2.68 mg kg-1 respectively with 95% confidence level (k = 2). The uncertainty evaluation has also been carried out in Pb determination following EURACHEM/GUM guidelines. The final analytical results quantifying uncertainty fulfills this requirement and gives a measure of the confidence level of the concerned laboratory. Gravimetry is the most reliable technique in comparison to titremetry and instrumental method and the results of gravimetry are directly traceable to SI unit. Gravimetric analysis, if methods are followed carefully, provides for exceedingly precise analysis. In classical gravimetry the major uncertainties are due to repeatability but in electro-gravimetry several other factors also affect the final results.

  5. The climate change convention and human health.

    Science.gov (United States)

    Rowbotham, E J

    1995-01-01

    The United Nations Framework Convention on Climate Change, signed at Rio in June 1992, is intended to minimize climate change and its impact. Much of its text is ambiguous and it is not specifically directed to health considerations. It is, however, recognized that adverse effects of climate change on health are a concern of humankind, and health is an integral part of the Convention. The Convention includes commitments by the developed countries to reduce emissions of greenhouse gases and to increase public awareness of these commitments. The significance of the Convention in these respects is discussed critically and future developments considered.

  6. Catalyst support structure, catalyst including the structure, reactor including a catalyst, and methods of forming same

    Science.gov (United States)

    Van Norman, Staci A.; Aston, Victoria J.; Weimer, Alan W.

    2017-05-09

    Structures, catalysts, and reactors suitable for use for a variety of applications, including gas-to-liquid and coal-to-liquid processes and methods of forming the structures, catalysts, and reactors are disclosed. The catalyst material can be deposited onto an inner wall of a microtubular reactor and/or onto porous tungsten support structures using atomic layer deposition techniques.

  7. Increased recovery of touch DNA evidence using FTA paper compared to conventional collection methods.

    Science.gov (United States)

    Kirgiz, Irina A; Calloway, Cassandra

    2017-04-01

    Tape lifting and FTA paper scraping methods were directly compared to traditional double swabbing for collecting touch DNA from car steering wheels (n = 70 cars). Touch DNA was collected from the left or right side of each steering wheel (randomized) using two sterile cotton swabs, while the other side was sampled using water-soluble tape or FTA paper cards. DNA was extracted and quantified in duplicate using qPCR. Quantifiable amounts of DNA were detected for 100% of the samples (n = 140) collected independent of the method. However, the DNA collection yield was dependent on the collection method. A statistically significant difference in DNA yield was observed between FTA scraping and double swabbing methods (p = 0.0051), with FTA paper collecting a two-fold higher amount. Statistical analysis showed no significant difference in DNA yields between the double swabbing and tape lifting techniques (p = 0.21). Based on the DNA concentration required for 1 ng input, 47% of the samples collected using FTA paper would be expected to yield a short tandem repeat (STR) profile compared to 30% and 23% using double swabbing or tape, respectively. Further, 55% and 77% of the samples collected using double swabbing or tape, respectively, did not yield a high enough DNA concentration for the 0.5 ng of DNA input recommended for conventional STR kits and would be expected to result in a partial or no profile compared to 35% of the samples collected using FTA paper. STR analysis was conducted for a subset of the higher concentrated samples to confirm that the DNA collected from the steering wheel was from the driver. 32 samples were selected with DNA amounts of at least 1 ng total DNA (100 pg/μl when concentrated if required). A mixed STR profile was observed for 26 samples (88%) and the last driver was the major DNA contributor for 29 samples (94%). For one sample, the last driver was the minor DNA contributor. A full STR profile of the last driver was observed for

  8. Standardizing Naming Conventions in Radiation Oncology

    Energy Technology Data Exchange (ETDEWEB)

    Santanam, Lakshmi [Department of Radiation Oncology, Washington University School of Medicine, St. Louis, MO (United States); Hurkmans, Coen [Department of Radiation Oncology, Catharina Hospital, Eindhoven (Netherlands); Mutic, Sasa [Department of Radiation Oncology, Washington University School of Medicine, St. Louis, MO (United States); Vliet-Vroegindeweij, Corine van [Department of Radiation Oncology, Thomas Jefferson University Hospital, Philadelphia, PA (United States); Brame, Scott; Straube, William [Department of Radiation Oncology, Washington University School of Medicine, St. Louis, MO (United States); Galvin, James [Department of Radiation Oncology, Thomas Jefferson University Hospital, Philadelphia, PA (United States); Tripuraneni, Prabhakar [Department of Radiation Oncology, Scripps Clinic, LaJolla, CA (United States); Michalski, Jeff [Department of Radiation Oncology, Washington University School of Medicine, St. Louis, MO (United States); Bosch, Walter, E-mail: wbosch@radonc.wustl.edu [Department of Radiation Oncology, Washington University School of Medicine, St. Louis, MO (United States); Advanced Technology Consortium, Image-guided Therapy QA Center, St. Louis, MO (United States)

    2012-07-15

    Purpose: The aim of this study was to report on the development of a standardized target and organ-at-risk naming convention for use in radiation therapy and to present the nomenclature for structure naming for interinstitutional data sharing, clinical trial repositories, integrated multi-institutional collaborative databases, and quality control centers. This taxonomy should also enable improved plan benchmarking between clinical institutions and vendors and facilitation of automated treatment plan quality control. Materials and Methods: The Advanced Technology Consortium, Washington University in St. Louis, Radiation Therapy Oncology Group, Dutch Radiation Oncology Society, and the Clinical Trials RT QA Harmonization Group collaborated in creating this new naming convention. The International Commission on Radiation Units and Measurements guidelines have been used to create standardized nomenclature for target volumes (clinical target volume, internal target volume, planning target volume, etc.), organs at risk, and planning organ-at-risk volumes in radiation therapy. The nomenclature also includes rules for specifying laterality and margins for various structures. The naming rules distinguish tumor and nodal planning target volumes, with correspondence to their respective tumor/nodal clinical target volumes. It also provides rules for basic structure naming, as well as an option for more detailed names. Names of nonstandard structures used mainly for plan optimization or evaluation (rings, islands of dose avoidance, islands where additional dose is needed [dose painting]) are identified separately. Results: In addition to its use in 16 ongoing Radiation Therapy Oncology Group advanced technology clinical trial protocols and several new European Organization for Research and Treatment of Cancer protocols, a pilot version of this naming convention has been evaluated using patient data sets with varying treatment sites. All structures in these data sets were

  9. Standardizing Naming Conventions in Radiation Oncology

    International Nuclear Information System (INIS)

    Santanam, Lakshmi; Hurkmans, Coen; Mutic, Sasa; Vliet-Vroegindeweij, Corine van; Brame, Scott; Straube, William; Galvin, James; Tripuraneni, Prabhakar; Michalski, Jeff; Bosch, Walter

    2012-01-01

    Purpose: The aim of this study was to report on the development of a standardized target and organ-at-risk naming convention for use in radiation therapy and to present the nomenclature for structure naming for interinstitutional data sharing, clinical trial repositories, integrated multi-institutional collaborative databases, and quality control centers. This taxonomy should also enable improved plan benchmarking between clinical institutions and vendors and facilitation of automated treatment plan quality control. Materials and Methods: The Advanced Technology Consortium, Washington University in St. Louis, Radiation Therapy Oncology Group, Dutch Radiation Oncology Society, and the Clinical Trials RT QA Harmonization Group collaborated in creating this new naming convention. The International Commission on Radiation Units and Measurements guidelines have been used to create standardized nomenclature for target volumes (clinical target volume, internal target volume, planning target volume, etc.), organs at risk, and planning organ-at-risk volumes in radiation therapy. The nomenclature also includes rules for specifying laterality and margins for various structures. The naming rules distinguish tumor and nodal planning target volumes, with correspondence to their respective tumor/nodal clinical target volumes. It also provides rules for basic structure naming, as well as an option for more detailed names. Names of nonstandard structures used mainly for plan optimization or evaluation (rings, islands of dose avoidance, islands where additional dose is needed [dose painting]) are identified separately. Results: In addition to its use in 16 ongoing Radiation Therapy Oncology Group advanced technology clinical trial protocols and several new European Organization for Research and Treatment of Cancer protocols, a pilot version of this naming convention has been evaluated using patient data sets with varying treatment sites. All structures in these data sets were

  10. Conventional and molecular methods used in the detection and subtyping of Yersinia enterocolitica in food.

    Science.gov (United States)

    Petsios, Stefanos; Fredriksson-Ahomaa, Maria; Sakkas, Hercules; Papadopoulou, Chrissanthy

    2016-11-21

    Yersinia enterocolitica is an important foodborne pathogen, but the prevalence in food is underestimated due to drawbacks in the detection methods. Problems arise from the low concentration of pathogenic strains present in food samples, similarities with other Enterobacteriaceae and Y. enterocolitica-like species and the heterogeneity of Y. enterocolitica as it comprises both pathogenic and non-pathogenic isolates. New rapid, cost-effective and more sensitive culture media and molecular techniques have been developed to overcome the drawbacks of conventional culture methods. Recent molecular subtyping methods have been applied to Y. enterocolitica strains to track infection sources and to investigate phylogenetic relationships between different Yersinia strains. Further application of modern subtyping tools such as WGS in a variety of bioserotypes, and comparison with other members of the genus will help to better understanding of the virulence determinants of pathogenic Y. enterocolitica, its mechanisms to cope in the host environments, and can contribute to the development of more specific detection and typing strategies.

  11. The Cost-Effectiveness of Conventional Discectomy Compared to Other Surgical Techniques for Lumbar Disk Herniation. A Systematic Review

    DEFF Research Database (Denmark)

    Thorsen, May Tone; Ødegaard-Olsen, Øystein; Leboeuf-Yde, Charlotte

    2018-01-01

    Background: The current study reviews the literature on the cost-effectiveness of conventional diskectomy compared to other surgical techniques, by assessing studies with economical evaluation and studies using proxy measures of cost-effectiveness. Methods: In April 2016, a comprehensive search w...... studies. The available evidence, however, suggests that any cost-effectiveness difference between conventional diskectomy and the alternatives is unlikely to be great.......Background: The current study reviews the literature on the cost-effectiveness of conventional diskectomy compared to other surgical techniques, by assessing studies with economical evaluation and studies using proxy measures of cost-effectiveness. Methods: In April 2016, a comprehensive search......-four articles were included in the review, 9 retrieved from the original search, and an additional 15 from reference lists. Four studies included an economical evaluation and 20 reported proxy measures of cost-effectiveness. The quality of studies varied considerably and results were ambiguous; the four...

  12. Conventional and CT angiography in children: dosimetry and dose comparisons

    International Nuclear Information System (INIS)

    Frush, Donald P.; Yoshizumi, Terry

    2006-01-01

    Tremendous advances have been made in imaging in children with both congenital and acquired heart disease. These include technical advances in cardiac catheterization and conventional angiography, especially with advancements in interventional procedures, as well as noninvasive imaging with MR and CT angiography. With rapid advances in multidetector CT (MDCT) technology, most recently 64-detector array systems (64-slice MDCT), have come a number of advantages over MR. However, both conventional and CT angiography impart radiation dose to children. Although the presence of radiation exposure to children has long been recognized, it is apparent that our ability to assess this dose, particularly in light of the rapid advancements, has been limited. Traditional methods of dosimetry for both conventional and CT angiography are somewhat cumbersome or involve a potential for substantial uncertainty. Recent developments in dosimetry, including metal oxide semiconductor field effect transistors (MOSFET) and the availability of anthropomorphic, tissue-equivalent phantoms have provided new opportunities for dosimetric assessments. Recent work with this technology in state-of-the-art cardiac angiography suites as well as with MDCT have offered direct comparisons of doses in infants and children undergoing diagnostic cardiac evaluation. It is with these dose data that assessment of risks, and ultimately the assessment of risk-benefit, can be better achieved. (orig.)

  13. Artificial neural networks versus conventional methods for boiling water reactor stability monitoring

    International Nuclear Information System (INIS)

    Hagen, T.H.J.J. van der

    1995-01-01

    The application of an artificial neural network (ANN) for boiling water reactor (BWR) stability monitoring was studied. A three-layer perceptron was trained on synthetic autocorrelation functions to estimate the decay ratio and the resonance frequency from measured neutron noise. Training of the ANN was improved by adding noise to the training patterns and by applying nonconventional error definitions in the generalized delta rule. The performance of the developed ANN was compared with those of conventional stability monitoring techniques. Explicit care was taken for generating unbiased test data. It is found that the trained ANN is capable of monitoring the stability of the Dodewaard BWR for four specific cases. By comparing properties such as the false alarm ratio, the alarm failure ratio, and the average time to alarm, it is shown that it performs worse than model-based methods in stability monitoring of exact second-order systems but that it is more robust (better resistant to corruptions of the input data and to deviations of the system at issue from an exact second-order system) than other methods. The latter explains its good performance on the Dodewaard BWR and is promising for the application of an ANN for stability monitoring of other reactors and for other operating conditions

  14. Comparison of conventional versus Hybrid knife peroral endoscopic myotomy methods for esophageal achalasia: a case-control study.

    Science.gov (United States)

    Tang, Xiaowei; Gong, Wei; Deng, Zhiliang; Zhou, Jieqiong; Ren, Yutang; Zhang, Qiang; Chen, Zhenyu; Jiang, Bo

    2016-01-01

    Peroral endoscopic myotomy (POEM) has been developed to treat achalasia as a novel less invasive modality. We aimed to compare the efficacy and safety of conventional knife versus Hybrid knife (HK) during POEM procedure. Between June 2012 and July 2014, 31 patients underwent POEM using HK in our department (HK group), and 36 patients underwent POEM using conventional method (injection needle and triangular tip [TT] knife, TT group). Procedure-related parameters, symptom relief, adverse events were compared between two groups. There were no significant differences in the age, sex and other baseline characteristics between the two groups. The mean procedural time was significantly shorter in HK group than TT group (53.0 ± 17.2 vs. 67.6 ± 28.4 min, p = 0.015). The mean frequency of devices exchange was 4.7 ± 1.7 in HK group and 10.9 ± 1.8 in TT group (p = 0.000). No serious adverse events occurred postoperatively in both groups. At one-year follow-up, a total of 94% treatment success was achieved in all patients (93.5% in HK group and 94.4% in TT group, p = 0.877). HK in POEM can shorten the procedural time, and achieve similar treatment success compared to conventional TT knife.

  15. Proceedings of the 2001 Canadian society of petroleum geologists annual convention

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    Founded in 1927 as the Alberta Society of Petroleum Geologists, the Canadian Society of Petroleum Geologists is dedicated to promote and further the study of petroleum and natural gas geology and all the study fields related to it. Its 3300 members represent Canada and 30 other countries. The annual convention is held to provide a forum for the exchange of information on topics related to petroleum geology and to foster the spirit of scientific research with the members. Another objective of the Society and annual convention is to make the general public aware of the need for professional and well-trained scientists. In excess of 100 presentations were made at the 2001 annual convention on topics that included petroleum potential in Somalia, seismic imaging, faulting and fault seal, multi-scale reservoir compartmentalization, non-invasive geochemical and remote sensing methods, and much more. refs., tabs., figs.

  16. A proposal on evaluation method of neutron absorption performance to substitute conventional neutron attenuation test

    International Nuclear Information System (INIS)

    Kim, Je Hyun; Shim, Chang Ho; Kim, Sung Hyun; Choe, Jung Hun; Cho, In Hak; Park, Hwan Seo; Park, Hyun Seo; Kim, Jung Ho; Kim, Yoon Ho

    2016-01-01

    For a verification of newly-developed neutron absorbers, one of guidelines on the qualification and acceptance of neutron absorbers is the neutron attenuation test. However, this approach can cause a problem for the qualifications that it cannot distinguish how the neutron attenuates from materials. In this study, an estimation method of neutron absorption performances for materials is proposed to detect both direct penetration and back-scattering neutrons. For the verification of the proposed method, MCNP simulations with the experimental system designed in this study were pursued using the polyethylene, iron, normal glass and the vitrified form. The results show that it can easily test neutron absorption ability using single absorber model. Also, from simulation results of single absorber and double absorbers model, it is verified that the proposed method can evaluate not only the direct thermal neutrons passing through materials, but also the scattered neutrons reflected to the materials. Therefore, the neutron absorption performances can be accurately estimated using the proposed method comparing with the conventional neutron attenuation test. It is expected that the proposed method can contribute to increase the reliability of the performance of neutron absorbers

  17. A proposal on evaluation method of neutron absorption performance to substitute conventional neutron attenuation test

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Je Hyun; Shim, Chang Ho [Dept. of Nuclear Engineering, Hanyang University, Seoul (Korea, Republic of); Kim, Sung Hyun [Nuclear Fuel Cycle Waste Treatment Research Division, Research Reactor Institute, Kyoto University, Osaka (Japan); Choe, Jung Hun; Cho, In Hak; Park, Hwan Seo [Ionizing Radiation Center, Nuclear Fuel Cycle Waste Treatment Research Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Park, Hyun Seo; Kim, Jung Ho; Kim, Yoon Ho [Ionizing Radiation Center, Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2016-12-15

    For a verification of newly-developed neutron absorbers, one of guidelines on the qualification and acceptance of neutron absorbers is the neutron attenuation test. However, this approach can cause a problem for the qualifications that it cannot distinguish how the neutron attenuates from materials. In this study, an estimation method of neutron absorption performances for materials is proposed to detect both direct penetration and back-scattering neutrons. For the verification of the proposed method, MCNP simulations with the experimental system designed in this study were pursued using the polyethylene, iron, normal glass and the vitrified form. The results show that it can easily test neutron absorption ability using single absorber model. Also, from simulation results of single absorber and double absorbers model, it is verified that the proposed method can evaluate not only the direct thermal neutrons passing through materials, but also the scattered neutrons reflected to the materials. Therefore, the neutron absorption performances can be accurately estimated using the proposed method comparing with the conventional neutron attenuation test. It is expected that the proposed method can contribute to increase the reliability of the performance of neutron absorbers.

  18. Overview of the IAEA Joint Convention and Implementation Status of the Obligation as the Contracting Party of the 5th Joint Convention

    International Nuclear Information System (INIS)

    Lee, Jeong Ken; Lee, Youn Keun; Ahn, Sang Myeon

    2016-01-01

    The Joint Convention on the Safety of Spent Fuel Management and on the Safety of Radioactive Waste Management (Joint Convention) was adopted on 5 September 1997 by a Diplomatic Conference convened by the International Atomic Energy Agency (IAEA). The Joint Convention was opened for signature at Vienna in September 1997 and will remain open for signature until its entry into force. Korean government signed the Joint Convention in 1997 and this Convention was effective in 2002 as the Convention No. 1612. This paper will show overview of the Joint Convention and implementation status of the obligation as a Contracting Party of the 5th Joint Convention. The Joint Convention is the inter-national convention organized by the IAEA. All contracting parties shall comply with rules of the Joint Convention and conduct the obligation of this convention. Korean government successfully conducted all obligation (attending Organization Meeting and Review Meeting, submitting paper including National Report, question paper and answer paper) of the 5th Joint Convention from May 2014 to May 2015, and will prepare the obligation of the 6th Joint Convention

  19. Precision Fit of Screw-Retained Implant-Supported Fixed Dental Prostheses Fabricated by CAD/CAM, Copy-Milling, and Conventional Methods.

    Science.gov (United States)

    de França, Danilo Gonzaga; Morais, Maria Helena; das Neves, Flávio D; Carreiro, Adriana Fonte; Barbosa, Gustavo As

    The aim of this study was to evaluate the effectiveness of fabrication methods (computer-aided design/computer-aided manufacture [CAD/CAM], copy-milling, and conventional casting) in the fit accuracy of three-unit, screw-retained fixed dental prostheses. Sixteen three-unit implant-supported screw-retained frameworks were fabricated to fit an in vitro model. Eight frameworks were fabricated using the CAD/CAM system, four in zirconia and four in cobalt-chromium. Four zirconia frameworks were fabricated using the copy-milled system, and four were cast in cobalt-chromium using conventional casting with premachined abutments. The vertical and horizontal misfit at the implant-framework interface was measured using scanning electron microscopy at ×250. The results for vertical misfit were analyzed using Kruskal-Wallis and Mann-Whitney tests. The horizontal misfits were categorized as underextended, equally extended, or overextended. Statistical analysis established differences between groups according to the chi-square test (α = .05). The mean vertical misfit was 5.9 ± 3.6 μm for CAD/CAM-fabricated zirconia, 1.2 ± 2.2 μm for CAD/CAM-fabricated cobalt-chromium frameworks, 7.6 ± 9.2 μm for copy-milling-fabricated zirconia frameworks, and 11.8 (9.8) μm for conventionally fabricated frameworks. The Mann-Whitney test revealed significant differences between all but the zirconia-fabricated frameworks. A significant association was observed between the horizontal misfits and the fabrication method. The percentage of horizontal misfits that were underextended and overextended was higher in milled zirconia (83.3%), CAD/CAM cobaltchromium (66.7%), cast cobalt-chromium (58.3%), and CAD/CAM zirconia (33.3%) frameworks. CAD/CAM-fabricated frameworks exhibit better vertical misfit and low variability compared with copy-milled and conventionally fabricated frameworks. The percentage of interfaces equally extended was higher when CAD/CAM and zirconia were used.

  20. Comparison of Vitek Matrix-assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry Versus Conventional Methods in Candida Identification.

    Science.gov (United States)

    Keçeli, Sema Aşkın; Dündar, Devrim; Tamer, Gülden Sönmez

    2016-02-01

    Candida species are generally identified by conventional methods such as germ tube or morphological appearance on corn meal agar, biochemical methods using API kits and molecular biological methods. Alternative to these methods, rapid and accurate identification methods of microorganisms called matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDİ-TOF MS) has recently been described. In this study, Candida identification results by API Candida kit, API 20C AUX kit and identifications on corn meal agar (CMA) are compared with the results obtained on Vitek-MS. All results were confirmed by sequencing internal transcribed spacer (ITS) regions of rDNA. Totally, 97 Candida strains were identified by germ tube test, CMA, API and Vitek-MS. Vitek-MS results were compatible with 74.2 % of API 20C AUX and 81.4 % of CMA results. The difference between the results of API Candida and API 20C AUX was detected. The ratio of discrepancy between Vitek-MS and API 20C AUX was 25.8 %. Candida species mostly identified as C. famata or C. tropicalis by and not compatible with API kits were identified as C. albicans by Vitek-MS. Sixteen Candida species having discrepant results with Vitek-MS, API or CMA were randomly chosen, and ITS sequence analysis was performed. The results of sequencing were compatible 56.2 % with API 20C AUX, 50 % with CMA and 93.7 % with Vitek-MS. When compared with conventional identification methods, MS results are more reliable and rapid for Candida identification. MS system may be used as routine identification method in clinical microbiology laboratories.

  1. Analysis of reverse heat transfer for conventional and optimized lubri-cooling methods during tangential surface grinding of ABNT 1020 steel

    Directory of Open Access Journals (Sweden)

    Henrique Cotait Razuk

    Full Text Available Abstract A numerical thermal model was developed to evaluate the heat flux which is conducted to a rectangular workpiece of steel plate ABNT 1020, thus making it possible to compute the maximum temperature in the grinding surface, taking into account the rectangular distribution of heat flux, the thermal properties of the grinding wheel conventional Al2O3, the piece to be machined and the lubri-refrigerating fluid. The finite volume method was employed for the discretization of the direct thermal problem from the heat diffusion equation associated with the two-dimensional problem of heat conduction in transient regime. The inverse thermal problem was solved by the Golden Section technique. The thermal flux, when compared to the conventional technique of method of application fluid, was reduced by 84.0% in the practices performed with cutting depth of 30µm, at 74.0% in practices with cutting depth of 45µm and 61.2% in the aggressive practices of 60µm, thus demonstrating the applicability of the optimized method for fluid application.

  2. Preliminary assessment on the differences of nuclear terrorism convention from the convention on the physical protection of nuclear material and amendment to the convention on the physical protection of nuclear material

    International Nuclear Information System (INIS)

    Midiana Ariethia; Muhamad Ilman A A; Mas Pungky Hendrawijaya

    2011-01-01

    The threat of acts of nuclear terrorism in all its forms and manifestations create the urgent need to enhance international cooperation between countries in designing and following practical and effective measures for the prevention of acts of terrorism and to counter and punish its offenders. Several United Nations Security Council Resolutions, such as UNSCR Number 1373 (2001), and UNSCR Number 1540 (2005), and the result of Nuclear Security Summit in 2010 that encourage the member countries of IAEA to ratify nuclear conventions as soon as possible, are the reasons that the Indonesian Government planning on ratifying The International Convention for The Suppression of Acts of Nuclear Terrorism (Nuclear Terrorism Convention). Nuclear Terrorism Convention is one of the 16 (sixteen) international instruments that must be ratified by the member countries of IAEA. Of the 16 (sixteen) international instruments, 3 (three) conventions are related to nuclear; Convention on the Physical Protection of Nuclear Material, Amendment to the Convention on the Physical Protection of Nuclear Material, dan Nuclear Terrorism Convention. This paper presents the preliminary assessment on the differences of Nuclear Terrorism Convention to The Convention on The Physical Protection of Nuclear Material and Amendment to The Convention on The Physical Protection of Nuclear Material. This assessment is important due to the plan of the Indonesian Government to ratify the Nuclear Terrorism Convention. The result of this assessment could be used by BAPETEN in the ratification process of the Nuclear Terrorism Convention. The method used in this assessment is references assessment. (author)

  3. Recent advances in conventional and contemporary methods for remediation of heavy metal-contaminated soils.

    Science.gov (United States)

    Sharma, Swati; Tiwari, Sakshi; Hasan, Abshar; Saxena, Varun; Pandey, Lalit M

    2018-04-01

    Remediation of heavy metal-contaminated soils has been drawing our attention toward it for quite some time now and a need for developing new methods toward reclamation has come up as the need of the hour. Conventional methods of heavy metal-contaminated soil remediation have been in use for decades and have shown great results, but they have their own setbacks. The chemical and physical techniques when used singularly generally generate by-products (toxic sludge or pollutants) and are not cost-effective, while the biological process is very slow and time-consuming. Hence to overcome them, an amalgamation of two or more techniques is being used. In view of the facts, new methods of biosorption, nanoremediation as well as microbial fuel cell techniques have been developed, which utilize the metabolic activities of microorganisms for bioremediation purpose. These are cost-effective and efficient methods of remediation, which are now becoming an integral part of all environmental and bioresource technology. In this contribution, we have highlighted various augmentations in physical, chemical, and biological methods for the remediation of heavy metal-contaminated soils, weighing up their pros and cons. Further, we have discussed the amalgamation of the above techniques such as physiochemical and physiobiological methods with recent literature for the removal of heavy metals from the contaminated soils. These combinations have showed synergetic effects with a many fold increase in removal efficiency of heavy metals along with economic feasibility.

  4. Minilaparotomy-Assisted Transmesenteric-Transjugular Intrahepatic Portosystemic Shunt: Comparison with Conventional Transjugular Approach

    Energy Technology Data Exchange (ETDEWEB)

    Jalaeian, Hamed, E-mail: hjalaeia@umn.edu; Talaie, Reza; D’Souza, Donna; Taleb, Shayandokht [University of Minnesota, Division of Interventional Radiology, Department of Radiology (United States); Noorbaloochi, Siamak [University of Minnesota, School of Medicine (United States); Flanagan, Siobhan; Hunter, David; Golzarian, Jafar [University of Minnesota, Division of Interventional Radiology, Department of Radiology (United States)

    2016-10-15

    PurposeThis study was performed to compare the intrahepatic shunt function outcome and procedural complications of minilaparotomy-assisted transmesenteric (MAT)-transjugular intrahepatic portosystemic shunt (TIPS) placement with the conventional transjugular method.MethodsThis is a retrospective review of all patients who had a MAT or conventional TIPS procedure over a 6-year period at our institute. The primary patency rate, fluoroscopy time, technical success, major procedure-related complications, and mortality data were compared between two treatment groups.ResultsWe included 49 patients with MAT-TIPS, and 63 with conventional TIPS, with an average follow-up of 21.43 months. The primary patency rates at 6 and 12 months were 82.9 and 66.7 % in the conventional TIPS group, and 81.0 and 76.5 % in the MAT-TIPS group (p = 1.000, and 0.529), respectively. There was no significant difference in technical success rate, post-procedure portosystemic pressure gradient, fluoroscopy time, and peri-procedural mortality rate between treatment groups. Major procedural-related complications were seen more frequently among MAT-TIPS patients (p = 0.012). In the MAT-TIPS group, 5 (10.2 %) patients developed post-procedure minilaparotomy, wound-related complications, and 5 (10.2 %) developed bacterial peritonitis; whereas, none of patients with conventional TIPS had either of these complications (p = 0.014).ConclusionWhile both MAT-TIPS and conventional TIPS had similar shunt primary patency rate and technical success rate, the MAT approach was associated with a significantly higher rate of minilaparotomy-related wound complications or infectious complications. These complications maybe prevented by a change in post-procedure monitoring and therapy.

  5. Extraction and comparison of proteins from natural rubber latex by conventional and ionizing radiation methods

    International Nuclear Information System (INIS)

    Rogero, Sizue O.; Spencer, Patrick J.; Campos, Vania E.; Lusvarghi, Fabio M.; Higa, Olga Z.

    1997-01-01

    Several proteins in natural rubber latex (NRL) have been assigned to be significant allergens. It is known that proteins submitted to ionizing radiation suffer denaturation and immunochemical modification resulting in low antigenic reactivity. The aim of this study was to extract and compare water extractable proteins from NRL films vulcanized by conventional and by ionizing radiation methods. SDS-polyacrylamide gel electrophoresis (SDS--PAGE) and high pressure liquid chromatography (HPLC) showed a diffuse protein band of about 14 KDa, which we believe is rubber elongation factor (REF), in both eluates, but smaller in latex film vulcanized by ionizing radiation. REF has been suggested to be a major latex allergen. These data suggest that ionizing radiation vulcanization could be an useful method for the production of NRL goods with low antigenicity. (author). 8 refs., 2 figs., 1 tab

  6. Comparative studies on conventional (water-hot acid) and non-conventional (ultrasonication) procedures for extraction and chemical characterization of pectin from peel waste of mango cultivar chaunsa

    International Nuclear Information System (INIS)

    Kausar, S.; Saeed, A.

    2015-01-01

    Pectin, a naturally occurring heteropolysaccharide, is widely used as a functional ingredient in food and pharmaceutical industries due to its gelling and stabilizing properties. During the present study pectin was extracted from peel of mango (cultivar Chaunsa) using conventional (water-hot acid) and non-conventional (ultrasonication) methods. In conventional method, HNO/sub 3/, H/sub 2/SO/sub 4/, or HCl was used under variable conditions of pH (2.0, 2.5, 3.0), temperature (70, 80, 90, 100 degree C), duration of extraction (30, 60, 90, 120 min), and solvents (ethanol, methanol, acetone, isopropyl alcohol). Maximum yield of 16.6 g pectin 100 g/sup -1/ peel was obtained with HNO/sub 3/ at pH 2.5, 90 degree C, 90 min extraction, and ethanol. Whereas in non-conventional method, ultrasonication was used for different time intervals (10, 20, 40 min) using HNO/sub 3/ at pH 2.5 and 90 degree C. Maximum yield of 15.8 g pectin 100 g/sup -1/ peel was obtained by this method in 20 min. Pectin extracted by the above two methods was found to be of high quality as was determined in respect of methoxyl and galacturonic acid contents, degree of esterification, equivalent weight, and FTIR spectra. Extraction of pectin from mango peel by employing non-conventional method (ultrasonication) was observed to be an energy efficient method due to its less extraction time (20 min as compared to 90 min in conventional method) suggesting its suitability on commercial scale for the extraction of pectin from mango and other available fruit peel wastes. (author)

  7. Methods to establish flaw tolerances

    International Nuclear Information System (INIS)

    Varga, T.

    1978-01-01

    Three conventional methods used to establish flaw tolerances are compared with new approaches using fracture mechanics. The conventional methods are those based on (a) non-destructive testing methods; (b) fabrication and quality assurance experience; and (c) service and damage experience. Pre-requisites of fracture mechanics methods are outlined, and summaries given of linear elastic mechanics (LEFM) and elastoplastic fracture mechanics (EPFM). The latter includes discussion of C.O.D.(crack opening displacement), the J-integral and equivalent energy. Proposals are made for establishing flaw tolerances. (U.K.)

  8. Technical Efficiency Performance of Conventional Banks

    OpenAIRE

    Endri, Endri

    2012-01-01

    This study aims to measure the performance of the technical efficiency of the conventional commercial banks during the period 2008-2009 by using non-parametric method of Data Envelopment Analysis (DEA). Test results showed that the total of all conventional commercial banks during the period 2008-2009 has not shown that optimal performance in which the level of technical efficiency is still below 100 percent. Appalling conditions, the efficiency of national banks experienced a decline of 73.5...

  9. Computed tomographic mammography using a conventional body scanner.

    Science.gov (United States)

    Chang, C H; Nesbit, D E; Fisher, D R; Fritz, S L; Dwyer, S J; Templeton, A W; Lin, F; Jewell, W R

    1982-03-01

    The technique for computed tomographic (CT) examination of the breasts using a conventional body scanner is described, and experience with 67 patients is reported. In the diagnosis of both malignant and benign breast lesions, the results with a body scanner were equal to those of a dedicated CT/M mammographic unit. Although the CT study of the breast cannot replace conventional mammography in screening or in routine diagnostic workup, the unique capability of demonstrating both anatomic changes and increased iodide concentration in a cancer provides many advantages over conventional mammography. CT mammography appears to have the capability to detect breast cancers that are occult to other methods. Indications for a CT study of the breasts are: (1) clinically suspected breast cancer, especially with a mammographically occult lesion; (2) questionable mammographic findings, including microcalcifications, tumor shape, architectural distortion, and uncertain lesion location; and (3) evaluation of postbiopsy or postlumpectomy breast cancers when a primary irradiation therapy is contemplated. Breast CT also appears to be a valuable diagnostic tool in searching for a second primary breast cancer, follow-up study of postirradiation of breast cancer, followup study for postmastectomy patients, and screening procedure for genetically high-risk patients, especially those with dense breasts.

  10. 15 CFR 742.18 - Chemical Weapons Convention (CWC or Convention).

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Chemical Weapons Convention (CWC or... REGULATIONS CONTROL POLICY-CCL BASED CONTROLS § 742.18 Chemical Weapons Convention (CWC or Convention). States... Use of Chemical Weapons and on Their Destruction, also known as the Chemical Weapons Convention (CWC...

  11. Analysis 'in vivo' of the employ of the Er:YAG laser and conventional method to remove carious tissue

    International Nuclear Information System (INIS)

    Ribeiro, Rafael Cardoso

    2002-01-01

    The aim of this study was to evaluate the removal of carious tissue employing the use of Er:YAG laser in comparison with the conventional burr rotary instrument. The wavelength of this laser is 2,64 μm and have a good absorption by the water and hydroxyapatite present in dental hard tissue. For this purpose were selected 24 molar teeth with occlusal carious, which were divided in random in two groups. For enamel, the laser energy used was in the interval from 250 mJ to 400 mJ, and the frequency range from 2 Hz to 4 Hz; for the dentine the energy laser range was from 150 mJ to 200 mJ and the laser frequency was in the range from 2 Hz to 6 Hz. For the evaluation of the results was used a questionaire to critical evaluation of the professional and another one to evaluation of the patient. The results have shown that the Er:YAG laser is able to remove carious enamel and dentin, without cause crunch or fracture and the irradiated surface was creasy. The patients reported greatest comfort when the cavity preparation was done with the Er:YAG laser than the conventional burr and all the patients treated reported prefer to future treatments the use of the Er:YAG laser. In conclusion, for the critical evaluation of the professional the treatment with the Er:YAG laser is a safe and effective method, and for the critical evaluation of the patient the treatment is one alternative more comfortable than the conventional method to remove caries. (author)

  12. Comparison of Conventional and Semi-Conventional Management ...

    African Journals Online (AJOL)

    Comparison of Conventional and Semi-Conventional Management Systems on the Performance and Carcass Yield of Broiler Chickens. ... TO AFRICAN RESEARCH. AFRICAN JOURNALS ONLINE (AJOL) · Journals · Advanced Search · USING AJOL · RESOURCES ... Journal Home > Vol 20, No 1 (2018) >. Log in or ...

  13. 10 CFR Appendix I to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Conventional Ranges, Conventional...

    Science.gov (United States)

    2010-01-01

    ... PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. I Appendix I to Subpart B of Part... between the center and the corners of the conventional gas oven on the diagonals of a horizontal plane...

  14. Guidelines for the verification and validation of expert system software and conventional software: Volume 2, Survey and assessment of conventional software verification and validation methods Revision 1, Final report

    International Nuclear Information System (INIS)

    Miller, L.A.; Groundwater, E.H.; Hayes, J.E.; Mirsky, S.M.

    1995-05-01

    By means of a literature survey, a comprehensive set of methods was identified for the verification and validation of conventional software. The 153 methods so identified were classified according to their appropriateness for various phases of a developmental life-cycle -- requirements, design, and implementation; the last category was subdivided into two, static testing and dynamic testing methods. The methods were then characterized in terms of eight rating factors, four concerning ease-of-use of the methods and four concerning the methods' power to detect defects. Based on these factors, two measurements were developed to permit quantitative comparisons among methods, a Cost-Benefit Metric and an Effectiveness Metric. The Effectiveness Metric was further refined to provide three different estimates for each method, depending on three classes of needed stringency of V ampersand V (determined by ratings of a system's complexity and required-integrity). Methods were then rank-ordered for each of the three classes in terms of their overall cost-benefits and effectiveness. The applicability was then assessed of each method for the four identified components of knowledge-based and expert systems, as well as the system as a whole

  15. Radiation exposure in X-ray angiography and comparisons between digital and conventional methods of imaging

    International Nuclear Information System (INIS)

    Schaberg, J.

    1987-01-01

    The more recent developments and techniques in the field of angiography are examined for associated radiation exposure risks for patients and investigators and then compared to the conventional methods of angiography. It could be shown that digital subtraction angiography is generally associated with a lesser risk of somatic exposure of the patient, provided that the equipment used offers an adjustable useful-beam range and focus. The fact that above-table X-ray tubes are now generally replaced with X-ray systems installed under the examination table permits the relatively high doses, to which investigators are exposed during angiography, to be reduced by a factor of 3. (DG) [de

  16. Guidelines for the verification and validation of expert system software and conventional software: Project summary. Volume 1

    International Nuclear Information System (INIS)

    Mirsky, S.M.; Hayes, J.E.; Miller, L.A.

    1995-03-01

    This eight-volume report presents guidelines for performing verification and validation (V ampersand V) on Artificial Intelligence (Al) systems with nuclear applications. The guidelines have much broader application than just expert systems; they are also applicable to object-oriented programming systems, rule-based systems, frame-based systems, model-based systems, neural nets, genetic algorithms, and conventional software systems. This is because many of the components of AI systems are implemented in conventional procedural programming languages, so there is no real distinction. The report examines the state of the art in verifying and validating expert systems. V ampersand V methods traditionally applied to conventional software systems are evaluated for their applicability to expert systems. One hundred fifty-three conventional techniques are identified and evaluated. These methods are found to be useful for at least some of the components of expert systems, frame-based systems, and object-oriented systems. A taxonomy of 52 defect types and their delectability by the 153 methods is presented. With specific regard to expert systems, conventional V ampersand V methods were found to apply well to all the components of the expert system with the exception of the knowledge base. The knowledge base requires extension of the existing methods. Several innovative static verification and validation methods for expert systems have been identified and are described here, including a method for checking the knowledge base open-quotes semanticsclose quotes and a method for generating validation scenarios. Evaluation of some of these methods was performed both analytically and experimentally. A V ampersand V methodology for expert systems is presented based on three factors: (1) a system's judged need for V ampersand V (based in turn on its complexity and degree of required integrity); (2) the life-cycle phase; and (3) the system component being tested

  17. Guidelines for the verification and validation of expert system software and conventional software: Project summary. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Mirsky, S.M.; Hayes, J.E.; Miller, L.A. [Science Applications International Corp., McLean, VA (United States)

    1995-03-01

    This eight-volume report presents guidelines for performing verification and validation (V&V) on Artificial Intelligence (Al) systems with nuclear applications. The guidelines have much broader application than just expert systems; they are also applicable to object-oriented programming systems, rule-based systems, frame-based systems, model-based systems, neural nets, genetic algorithms, and conventional software systems. This is because many of the components of AI systems are implemented in conventional procedural programming languages, so there is no real distinction. The report examines the state of the art in verifying and validating expert systems. V&V methods traditionally applied to conventional software systems are evaluated for their applicability to expert systems. One hundred fifty-three conventional techniques are identified and evaluated. These methods are found to be useful for at least some of the components of expert systems, frame-based systems, and object-oriented systems. A taxonomy of 52 defect types and their delectability by the 153 methods is presented. With specific regard to expert systems, conventional V&V methods were found to apply well to all the components of the expert system with the exception of the knowledge base. The knowledge base requires extension of the existing methods. Several innovative static verification and validation methods for expert systems have been identified and are described here, including a method for checking the knowledge base {open_quotes}semantics{close_quotes} and a method for generating validation scenarios. Evaluation of some of these methods was performed both analytically and experimentally. A V&V methodology for expert systems is presented based on three factors: (1) a system`s judged need for V&V (based in turn on its complexity and degree of required integrity); (2) the life-cycle phase; and (3) the system component being tested.

  18. Comparative evaluation of the efficacy of chemomechanical caries removal agent (Papacarie and conventional method of caries removal: An in vitro study

    Directory of Open Access Journals (Sweden)

    Jawa D

    2010-06-01

    Full Text Available Painless dentistry, minimal intervention and thus giving comfort, relief and solace and instill positive attitude toward dental treatments, are some of the factors justifying the specialty of pediatric dentistry. Thus, this in vitro study was undertaken to compare the efficacy of a new chemomechanical caries removal agent, Papacarie (Formula and Acao, with conventional slow-speed rotary instrument (bur. Papacarie is a new formulation and has the main active ingredient papain, an endoprotein with bactericidal, bacteriostatic and anti-inflammatory actions. Twenty extracted human molar teeth with deep dentine caries and no enamel coverage were selected for the study. After the preparation of the teeth and removal of the caries with the respective methods, they were decalcified, dehydrated and embedded in paraffin blocks for histologic studies. Serial sections of 5 μm thickness were examined for the presence of bacteria under light microscope. Though complete removal of caries was achieved significantly in both the methods, there was less marked destruction of dentinal tubules in chemomechanical caries removal method by Papacarie. Thus, Papacarie is recommended as an efficient, easy to perform, comfortable and less destructive solution for the patient seeking an alternative to the conventional method.

  19. Guidelines for the verification and validation of expert system software and conventional software. Volume 1: Project summary. Final report

    International Nuclear Information System (INIS)

    Miller, L.A.; Hayes, J.E.; Mirsky, S.M.

    1995-05-01

    This eight-volume report presents guidelines for performing verification and validation (V ampersand V) on Artificial Intelligence (AI) systems with nuclear applications. The guidelines have much broader application than just expert systems; they are also applicable to object-oriented programming systems, rule-based systems, frame-based systems, model-based systems, neural nets, genetic algorithms, and conventional software systems. This is because many of the components of AI systems are implemented in conventional procedural programming languages, so there is no real distinction. The report examines the state of the art in verifying and validating expert systems. V ampersand V methods traditionally applied to conventional software systems are evaluated for their applicability to expert systems. One hundred fifty-three conventional techniques are identified and evaluated. These methods are found to be useful for at least some of the components of expert systems, frame-based systems, and object-oriented systems. A taxonomy of 52 defect types and their delectability by the 153 methods is presented. With specific regard to expert systems, conventional V ampersand V methods were found to apply well to all the components of the expert system with the exception of the knowledge base. The knowledge base requires extension of the existing methods. Several innovative static verification and validation methods for expert systems have been identified and are described here, including a method for checking the knowledge base open-quotes semanticsclose quotes and a method for generating validation scenarios. Evaluation of some of these methods was performed both analytically and experimentally

  20. Rapid descriptive sensory methods – Comparison of Free Multiple Sorting, Partial Napping, Napping, Flash Profiling and conventional profiling

    DEFF Research Database (Denmark)

    Dehlholm, Christian; Brockhoff, Per B.; Meinert, Lene

    2012-01-01

    is a modal restriction of Napping to specific sensory modalities, directing sensation and still allowing a holistic approach to products. The new methods are compared to Flash Profiling, Napping and conventional descriptive sensory profiling. Evaluations are performed by several panels of expert assessors......Two new rapid descriptive sensory evaluation methods are introduced to the field of food sensory evaluation. The first method, free multiple sorting, allows subjects to perform ad libitum free sortings, until they feel that no more relevant dissimilarities among products remain. The second method...... are applied for the graphical validation and comparisons. This allows similar comparisons and is applicable to single-block evaluation designs such as Napping. The partial Napping allows repetitions on multiple sensory modalities, e.g. appearance, taste and mouthfeel, and shows the average...

  1. The comparative study of conventional and innovative phlebographies in lower extremity

    International Nuclear Information System (INIS)

    Chen Guoping; Gu Jianping; He Xu; Lou Wensheng; Chen Liang; Su Haobo; Song Jinghua

    2008-01-01

    Objective: The clinical values of conventional phlebography via percutaneous dorsal pedal vein access with scalp puncture was compared with innovative phlebography via a percutaneous great saphenous approach with retained catheter in lower extremity for detection of venous diseases. Methods: Conventional and innovative phlebographies in lower extremity were performed in 34 suffering lower extremities of 30 patients, and the efficacy of the two methods was compared in demonstrating the venous diseases in lower extremities. Results: The rates of vascular display of the common iliac vein, the valve of saphenous-femoral vein and the first couple valve of femoral vein were 100%, 100% and 91.18% respectively with innovative phlebography while the rates of vascular display were 32.25%, 73.53% and 64.71% respectively with conventional phlebography. Iliac vein compression syndrome (IVCS), venous valvular disfunction of saphenous-femoral vein and the venous valvular disfunction of the first couple valve of femoral vein were shown in 14, 25 and 21 cases respectively by innovative phlebography, and in 3, 14 and 12 cases respectively by conventional phlebography in patients suffering from varicose veins and chronic swelling of the lower extremities. There was significant difference between the innovative and conventional phlebographies (P < 0.05). Conclusion: The innovative phlebography possesses a higher efficacy in diagnosing IVCS, venous valvular disfunctions of saphenous-femoral vein and the first couple valve of femoral vein compared with conventional method. It would be an alternative method to the conventional one or percutaneous femoral venous approach. (authors)

  2. Force measuring valve assemblies, systems including such valve assemblies and related methods

    Science.gov (United States)

    DeWall, Kevin George [Pocatello, ID; Garcia, Humberto Enrique [Idaho Falls, ID; McKellar, Michael George [Idaho Falls, ID

    2012-04-17

    Methods of evaluating a fluid condition may include stroking a valve member and measuring a force acting on the valve member during the stroke. Methods of evaluating a fluid condition may include measuring a force acting on a valve member in the presence of fluid flow over a period of time and evaluating at least one of the frequency of changes in the measured force over the period of time and the magnitude of the changes in the measured force over the period of time to identify the presence of an anomaly in a fluid flow and, optionally, its estimated location. Methods of evaluating a valve condition may include directing a fluid flow through a valve while stroking a valve member, measuring a force acting on the valve member during the stroke, and comparing the measured force to a reference force. Valve assemblies and related systems are also disclosed.

  3. Quasimonochromatic x-ray computed tomography by the balanced filter method using a conventional x-ray source

    International Nuclear Information System (INIS)

    Saito, Masatoshi

    2004-01-01

    A quasimonochromatic x-ray computed tomography (CT) system utilizing balanced filters has recently been developed for acquiring quantitative CT images. This system consisted of basic components such as a conventional x-ray generator for radiography, a stage for mounting and rotating objects, and an x-ray line sensor camera. Metallic sheets of Er and Yb were used as the balanced filters for obtaining quasimonochromatic incident x rays that include the characteristic lines of the W Kα doublet from a tungsten target. The mean energy and energy width of the quasimonochromatic x rays were determined to be 59.0 and 1.9 keV, respectively, from x-ray spectroscopic measurements using a high-purity Ge detector. The usefulness of the present x-ray CT system was demonstrated by obtaining spatial distributions of the linear attenuation coefficients of three selected samples--a 20 cm diameter cylindrical water phantom, a 3.5 cm diameter aluminum rod, and a human head phantom. The results clearly indicate that this apparatus is surprisingly effective for estimating the distribution of the linear attenuation coefficients without any correction of the beam-hardening effect. Thus, implementing the balanced filter method on an x-ray CT scanner has promise in producing highly quantitative CT images

  4. The Burning Plasma Experiment conventional facilities

    International Nuclear Information System (INIS)

    Commander, J.C.

    1991-01-01

    The Burning Program Plasma Experiment (BPX) is phased to start construction of conventional facilities in July 1994, in conjunction with the conclusion of the Tokamak Fusion Test Reactor (TFTR) project. This paper deals with the conceptual design of the BPX Conventional Facilities, for which Functional and Operational Requirements (F ampersand ORs) were developed. Existing TFTR buildings and utilities will be adapted and used to satisfy the BPX Project F ampersand ORs to the maximum extent possible. However, new conventional facilities will be required to support the BPX project. These facilities include: The BPX building; Site improvements and utilities; the Field Coil Power Conversion (FCPC) building; the TFTR modifications; the Motor Generation (MG) building; Liquid Nitrogen (LN 2 ) building; and the associated Instrumentation and Control (I ampersand C) systems. The BPX building will provide for safe and efficient shielding, housing, operation, handling, maintenance and decontamination of the BPX and its support systems. Site improvements and utilities will feature a utility tunnel which will provide a space for utility services--including pulse power duct banks and liquid nitrogen coolant lines. The FCPC building will house eight additional power supplied for the Toroidal Field (TF) coils. The MG building will house the two MG sets larger than the existing TFTR MG sets. This paper also addresses the conventional facility cost estimating methodology and the rationale for the construction schedule developed. 6 figs., 1 tab

  5. National nuclear safety report 2004. Convention on nuclear safety

    International Nuclear Information System (INIS)

    2004-01-01

    The second National Nuclear Safety Report was presented at the second review meeting of the Nuclear Safety Convention. At that time it was concluded that Argentina met the obligations of the Convention. This third National Nuclear Safety Report is an updated report which includes all safety aspects of the Argentinian nuclear power plants and the measures taken to enhance the safety of the plants. The present report also takes into account the observations and discussions maintained during the second review meeting. The conclusion made in the first review meeting about the compliance by Argentina of the obligations of the Convention are included as Annex I and those belonging to the second review meeting are included as Annex II. In general, the information contained in this Report has been updated since March 31, 2001 to April 30, 2004. Those aspects that remain unchanged were not addressed in this third report. As a result of the detailed analysis of all the Articles, it can be stated that the country fulfils all the obligations imposed by the Nuclear Safety Convention. The questions and answers originated at the Second Review Meeting are included as Annex III

  6. Guidelines regarding National Reports under the Convention on Nuclear Safety

    International Nuclear Information System (INIS)

    2013-01-01

    These Guidelines, established by the Contracting Parties pursuant to Article 22 of the Convention on Nuclear Safety (hereinafter called the Convention), are intended to be read in conjunction with the text of the Convention. Their purpose is to provide guidance to the Contracting Parties regarding material that may be useful to include in the National Reports required under Article 5 of the Convention and thereby to facilitate the most efficient review of implementation by the Contracting Parties of their obligations under the Convention.

  7. Blood culture bottles are superior to conventional media for vitreous culture.

    Science.gov (United States)

    Thariya, Patsuda; Yospaiboon, Yosanan; Sinawat, Suthasinee; Sanguansak, Thuss; Bhoomibunchoo, Chavakij; Laovirojjanakul, Wipada

    2016-08-01

    To compare blood culture bottles and conventional media for the vitreous culture in patients with clinically suspected infectious endophthalmitis. Retrospective comparative study at KKU Eye Center, Khon Kaen University. There were 342 patients with clinically suspected infectious endophthalmitis participated in the study. The vitreous specimens were inoculated in both blood culture bottles and on conventional culture media (blood agar, MacConkey agar, chocolate agar, Sabouraud dextrose agar and thioglycolate broth). The number of positive culture yields in both blood culture bottles and conventional media. Positive culture yields in both methods were found in 151 eyes (49.5%). There were 136 of 151 eyes (90.1%) with positive culture in blood culture bottles, whereas 99 of 151 eyes (65.6%) yielded positive cultures in conventional media. These findings were different with a statistical significance (P culture bottles and conventional media improved the yield. Blood culture bottles are superior to conventional media for vitreous culture in clinically suspected infectious endophthalmitis. Vitreous culture using blood culture bottles should be recommended as the primary method for microbiological diagnosis. A combination of both methods further improves the positive culture yield. © 2016 Royal Australian and New Zealand College of Ophthalmologists.

  8. Has the ThinPrep method of cervical screening maintained its improvement over conventional smears in terms of specimen adequacy?

    LENUS (Irish Health Repository)

    Treacy, A

    2009-04-01

    Liquid-based cytology (LBC) has replaced conventional smear assessment in many centers over recent years. In our laboratory this transfer took place in 1999. At that time we performed a split sample study comparing the conventional method of cervical smear evaluation with the ThinPrep system. This split sample study identified a dramatic improvement in specimen adequacy with LBC. While 11% of conventional preparations were reported as unsatisfactory and almost 9% were reported as suboptimal, evaluation of the same cases using LBC saw this combined figure reduced to 2.3%. AIM: To evaluate whether this dramatic fall in unsatisfactory smears has been maintained with the use of LBC. The database for all smears reported for 2005 (100% LBC) was interrogated. The number of unsatisfactory reports was calculated. The reason for an unsatisfactory report was recorded for each case. The overall unsatisfactory rate was compared with that reported in the 1999 split sample study. A total of 41,312 smear tests were reported in 2005. 1,342 (3.25%) were reported as unsatisfactory. Our findings support the ongoing value of LBC in a routine cervical screening laboratory in terms of continuing to maintain a low rate of unsatisfactory smears.

  9. Composite materials and bodies including silicon carbide and titanium diboride and methods of forming same

    Science.gov (United States)

    Lillo, Thomas M.; Chu, Henry S.; Harrison, William M.; Bailey, Derek

    2013-01-22

    Methods of forming composite materials include coating particles of titanium dioxide with a substance including boron (e.g., boron carbide) and a substance including carbon, and reacting the titanium dioxide with the substance including boron and the substance including carbon to form titanium diboride. The methods may be used to form ceramic composite bodies and materials, such as, for example, a ceramic composite body or material including silicon carbide and titanium diboride. Such bodies and materials may be used as armor bodies and armor materials. Such methods may include forming a green body and sintering the green body to a desirable final density. Green bodies formed in accordance with such methods may include particles comprising titanium dioxide and a coating at least partially covering exterior surfaces thereof, the coating comprising a substance including boron (e.g., boron carbide) and a substance including carbon.

  10. Initiation devices, initiation systems including initiation devices and related methods

    Energy Technology Data Exchange (ETDEWEB)

    Daniels, Michael A.; Condit, Reston A.; Rasmussen, Nikki; Wallace, Ronald S.

    2018-04-10

    Initiation devices may include at least one substrate, an initiation element positioned on a first side of the at least one substrate, and a spark gap electrically coupled to the initiation element and positioned on a second side of the at least one substrate. Initiation devices may include a plurality of substrates where at least one substrate of the plurality of substrates is electrically connected to at least one adjacent substrate of the plurality of substrates with at least one via extending through the at least one substrate. Initiation systems may include such initiation devices. Methods of igniting energetic materials include passing a current through a spark gap formed on at least one substrate of the initiation device, passing the current through at least one via formed through the at least one substrate, and passing the current through an explosive bridge wire of the initiation device.

  11. NON-CONVENTIONAL MACHINING PROCESSES SELECTION USING MULTI-OBJECTIVE OPTIMIZATION ON THE BASIS OF RATIO ANALYSIS METHOD

    Directory of Open Access Journals (Sweden)

    MILOŠ MADIĆ

    2015-11-01

    Full Text Available The role of non-conventional machining processes (NCMPs in today’s manufacturing environment has been well acknowledged. For effective utilization of the capabilities and advantages of different NCMPs, selection of the most appropriate NCMP for a given machining application requires consideration of different conflicting criteria. The right choice of the NCMP is critical to the success and competitiveness of the company. As the NCMP selection problem involves consideration of different conflicting criteria, of different relative importance, the multi-criteria decision making (MCDM methods are very useful in systematical selection of the most appropriate NCMP. This paper presents the application of a recent MCDM method, i.e., the multi-objective optimization on the basis of ratio analysis (MOORA method to solve NCMP selection which has been defined considering different performance criteria of four most widely used NCMPs. In order to determine the relative significance of considered quality criteria a pair-wise comparison matrix of the analytic hierarchy process was used. The results obtained using the MOORA method showed perfect correlation with those obtained by the technique for order preference by similarity to ideal solution (TOPSIS method which proves the applicability and potentiality of this MCDM method for solving complex NCMP selection problems.

  12. Reframing less conventional speech to disrupt conventions of "compulsory fluency": A conversation analysis approach

    Directory of Open Access Journals (Sweden)

    Camille Duque

    2018-05-01

    Full Text Available Our purpose is to illuminate compliances with, and resistances to, what we are calling "compulsory fluency" which we define as conventions for what constitutes competent speech. We achieve our purpose through a study of day-to-day communication between a woman with less conventional speech and her support providing family members and friends. Drawing from McRuer's (2006 compulsory ablebodiedness and Kafer's (2013 compulsory able-mindedness, we use "compulsory fluency" to refer to a form of articulation that is standardized and idealized and imposed on all speakers including those whose speech is less conventional. We see compulsory fluency as central to North American conceptions of personhood which are tied to individual ability to speak for one's self (Brueggemann, 2005. In this paper, we trace some North American principles for linguistic competence to outline widely held ideals of receptive and expressive language use, namely, conventions for how language should be understood and expressed. Using Critical Disability Studies (Goodley, 2013; McRuer, 2006 together with a feminist framework of relational autonomy (Nedelsky, 1989, our goal is to focus on experiences of people with less conventional speech and draw attention to power in communication as it flows in idiosyncratic and intersubjective fashion (Mackenzie & Stoljar, 2000; Westlund, 2009. In other words, we use a critical disability and feminist framing to call attention to less conventional forms of communication competence and, in this process, we challenge assumptions about what constitutes competent speech. As part of a larger qualitative study, we conduct a conversation analysis informed by Rapley and Antaki (1996 to examine day-to-day verbal, vocal and non-verbal communications of a young woman who self identifies as "having autism" - pseudonym Addison - in interaction with her support-providing family members and friends. We illustrate a multitude of Addison's compliances with

  13. A simple gold nanoparticle-mediated immobilization method to fabricate highly homogeneous DNA microarrays having higher capacities than those prepared by using conventional techniques

    International Nuclear Information System (INIS)

    Jung, Cheulhee; Mun, Hyo Young; Li, Taihua; Park, Hyun Gyu

    2009-01-01

    A simple, highly efficient immobilization method to fabricate DNA microarrays, that utilizes gold nanoparticles as the mediator, has been developed. The fabrication method begins with electrostatic attachment of amine-modified DNA to gold nanoparticles. The resulting gold-DNA complexes are immobilized on conventional amine or aldehyde functionalized glass slides. By employing gold nanoparticles as the immobilization mediator, implementation of this procedure yields highly homogeneous microarrays that have higher binding capacities than those produced by conventional methods. This outcome is due to the increased three-dimensional immobilization surface provided by the gold nanoparticles as well as the intrinsic effects of gold on emission properties. This novel immobilization strategy gives microarrays that produce more intense hybridization signals for the complementary DNA. Furthermore, the silver enhancement technique, made possible only in the case of immobilized gold nanoparticles on the microarrays, enables simple monitoring of the integrity of the immobilized DNA probe.

  14. Beyond Vienna and Montreal: A global framework convention on greenhouse gases

    International Nuclear Information System (INIS)

    Wirth, D.A.; Lashof, D.A.

    1993-01-01

    This chapter discusses the need for a framework treaty analogous to the Vienna Convention and to the Montreal Protocol for greenhouse gases. Discussed are the following topics: (1) the immediate need for multilateral greenhouse gas controls, including policy implications of scientific uncertainties; (2) recent steps toward a greenhouse gas convention; (3) an environmentally meaningful plan for a greenhouse gase conventions, including the ozone precident, CO 2 targets, resource transfers, trading emissions allocations, institutional issues

  15. Pest management strategies: Area-wide and conventional

    International Nuclear Information System (INIS)

    Lindquist, D.A.

    2000-01-01

    part of the cost of an area-wide programme will be fighting the target pest away from the commercial production - before the commercial crops are susceptible - on wild or alternate hosts or abandoned orchards, untreated host plants in homeowners' gardens, etc. In most cases, area-wide insect control will be the responsibility of a separate organisation hired by the producers. A separate organisation can plan an aggressive offense against the target pest population over the entire area. High technology systems can be effectively utilised to plan the population management programme. Included will be satellite imagery to detect alternate hosts, sensitive methods to detect movement of the pest populations, computer programmes to predict changes in the pest insect population based on biological parameters, a systems approach to utilise natural enemies on an area-wide basis, genetic analysis to detect the development of resistance and utilisation of systems to delay the development of resistance over the total area. Further, area-wide programmes encourage the use of specialised methods of insect control that are not effective or are not used on a farm by farm basis. These include the sterile insect technique (SIT), male annihilation, inundative releases of parasites, mating inhibitors, large-scale trap cropping with very attractive plants, treatment of alternate hosts on public lands and hosts in private gardens, etc. The objective of area-wide control is to reduce the pest population within the target area to a non-economic level. This is accomplished by attacking the entire insect pest population in the target area. Conventional insect control attempts to protect the plant or animal, is carried out by individual producers over a small area with little planning, is short-term, low technology and is a reactive (defense) approach to insect control. Area-wide insect control attempts to reduce the pest population to a non-economic level over a large area involving many

  16. National report of Brazil. Nuclear Safety Convention

    International Nuclear Information System (INIS)

    1998-09-01

    This document represents the national report prepared as a fulfillment of the brazilian obligations related to the Convention on Nuclear Safety. In chapter 2 some details are given about the existing nuclear installations. Chapter 3 provides details about the legislation and regulations, including the regulatory framework and the regulatory body. Chapter 4 covers general safety considerations as described in articles 10 to 16 of the Convention. Chapter 5 addresses to the safety of the installations during siting, design, construction and operation. Chapter 6 describes planned activities to further enhance nuclear safety. Chapter 7 presents the final remarks related to the degree of compliance with the Convention obligations

  17. Correlation and agreement of a digital and conventional method to measure arch parameters.

    Science.gov (United States)

    Nawi, Nes; Mohamed, Alizae Marny; Marizan Nor, Murshida; Ashar, Nor Atika

    2018-01-01

    The aim of the present study was to determine the overall reliability and validity of arch parameters measured digitally compared to conventional measurement. A sample of 111 plaster study models of Down syndrome (DS) patients were digitized using a blue light three-dimensional (3D) scanner. Digital and manual measurements of defined parameters were performed using Geomagic analysis software (Geomagic Studio 2014 software, 3D Systems, Rock Hill, SC, USA) on digital models and with a digital calliper (Tuten, Germany) on plaster study models. Both measurements were repeated twice to validate the intraexaminer reliability based on intraclass correlation coefficients (ICCs) using the independent t test and Pearson's correlation, respectively. The Bland-Altman method of analysis was used to evaluate the agreement of the measurement between the digital and plaster models. No statistically significant differences (p > 0.05) were found between the manual and digital methods when measuring the arch width, arch length, and space analysis. In addition, all parameters showed a significant correlation coefficient (r ≥ 0.972; p digital and manual measurements. Furthermore, a positive agreement between digital and manual measurements of the arch width (90-96%), arch length and space analysis (95-99%) were also distinguished using the Bland-Altman method. These results demonstrate that 3D blue light scanning and measurement software are able to precisely produce 3D digital model and measure arch width, arch length, and space analysis. The 3D digital model is valid to be used in various clinical applications.

  18. [A comparative study between the Vitek YBC and Microscan Walk Away RYID automated systems with conventional phenotypic methods for the identification of yeasts of clinical interest].

    Science.gov (United States)

    Ferrara, Giuseppe; Mercedes Panizol, Maria; Mazzone, Marja; Delia Pequeneze, Maria; Reviakina, Vera

    2014-12-01

    The aim of this study was to compare the identification of clin- ically relevant yeasts by the Vitek YBC and Microscan Walk Away RYID automated methods with conventional phenotypic methods. One hundred and ninety three yeast strains isolated from clinical samples and five controls strains were used. All the yeasts were identified by the automated methods previously mentioned and conventional phenotypic methods such as carbohydrate assimilation, visualization of microscopic morphology on corn meal agar and the use of chromogenic agar. Variables were assessed by 2 x 2 contingency tables, McNemar's Chi square, the Kappa index, and concordance values were calculated, as well as major and minor errors for the automated methods. Yeasts were divided into two groups: (1) frequent isolation and (2) rare isolation. The Vitek YBC and Microscan Walk Away RYID systems were concordant in 88.4 and 85.9% respectively, when compared to conventional phenotypic methods. Although both automated systems can be used for yeasts identification, the presence of major and minor errors indicates the possibility of misidentifications; therefore, the operator of this equipment must use in parallel, phenotypic tests such as visualization of microscopic morphology on corn meal agar and chromogenic agar, especially against infrequently isolated yeasts. Automated systems are a valuable tool; however, the expertise and judgment of the microbiologist are an important strength to ensure the quality of the results.

  19. Convention on nuclear safety. Final act

    International Nuclear Information System (INIS)

    1994-01-01

    The Diplomatic Conference, which was convened by the International Atomic Energy Agency at its Headquarters from 14 to 17 June 1994, adopted the Convention on Nuclear Safety reproduced in document INFCIRC/449 and the Final Act of the Conference. The text of the Final Act of the Conference, including an annexed document entitled ''Some clarification with respect to procedural and financial arrangements, national reports, and the conduct of review meetings, envisaged in the Convention on Nuclear Safety'', is reproduced in the Attachment hereto for the information of all Member States

  20. A novel technique for including surface tension in PLIC-VOF methods

    Energy Technology Data Exchange (ETDEWEB)

    Meier, M.; Yadigaroglu, G. [Swiss Federal Institute of Technology, Nuclear Engineering Lab. ETH-Zentrum, CLT, Zurich (Switzerland); Smith, B. [Paul Scherrer Inst. (PSI), Villigen (Switzerland). Lab. for Thermal-Hydraulics

    2002-02-01

    Various versions of Volume-of-Fluid (VOF) methods have been used successfully for the numerical simulation of gas-liquid flows with an explicit tracking of the phase interface. Of these, Piecewise-Linear Interface Construction (PLIC-VOF) appears as a fairly accurate, although somewhat more involved variant. Including effects due to surface tension remains a problem, however. The most prominent methods, Continuum Surface Force (CSF) of Brackbill et al. and the method of Zaleski and co-workers (both referenced later), both induce spurious or 'parasitic' currents, and only moderate accuracy in regards to determining the curvature. We present here a new method to determine curvature accurately using an estimator function, which is tuned with a least-squares-fit against reference data. Furthermore, we show how spurious currents may be drastically reduced using the reconstructed interfaces from the PLIC-VOF method. (authors)

  1. A rigorous assessment of tree height measurements obtained using airborne LIDAR and conventional field methods.

    Science.gov (United States)

    Hans-Erik Andersen; Stephen E. Reutebuch; Robert J. McGaughey

    2006-01-01

    Tree height is an important variable in forest inventory programs but is typically time-consuming and costly to measure in the field using conventional techniques. Airborne light detection and ranging (LIDAR) provides individual tree height measurements that are highly correlated with field-derived measurements, but the imprecision of conventional field techniques does...

  2. Comparison of conventional gauze therapy with vacuum assisted closure wound therapy in acute traumatic wounds

    International Nuclear Information System (INIS)

    Naqvi, S.H.; Jalil, M.; Butt, Q.; Malik, Z.U

    2013-01-01

    Objective: To compare the Vacuum Assisted Closure (Vac) wound therapy with Conventional Gauze Therapy (CGT) in management of acute traumatic wounds on the basis of time taken to achieve a vital red wound ready for definitive surgical closure. Study Design: Randomized control trial. Place and Duration of Study: Department of Surgery Combined Military Hospital Rawalpindi from Mar 2009 to Sep 2009. Patients and Methods: This study included 82 patients of acute traumatic wounds. Patients were randomly allotted to group A, in which wound was treated with new method of vacuum assisted closure (VAC) wound therapy and to group B, in which wound was managed by conventional gauze therapy (CGT). Outcomes were measured by the presence of vital red wound ready to be closed by surgical intervention. Patients with concomitant systemic pathology were not included in study. Results: Comparison between the two groups revealed mean time for wound healing 13 days in group A and 16.9 days in group B with significant difference (p value =0.029). Conclusion: Vacuum assisted closure wound therapy is an effective method in reducing time of wound healing for definitive surgical closure. (author)

  3. Comparative study of long-term outcomes of accelerated and conventional collagen crosslinking for progressive keratoconus.

    Science.gov (United States)

    Males, J J; Viswanathan, D

    2018-01-01

    PurposeTo compare the long-term outcomes of accelerated corneal collagen crosslinking (CXL) to conventional CXL for progressive keratoconus.Patients and methodsComparative clinical study of consecutive progressive keratoconic eyes that underwent either accelerated CXL (9 mW/cm 2 ultraviolet A (UVA) light irradiance for 10 min) or conventional CXL (3 mW/cm 2 UVA light irradiance for 30 min). Eyes with minimum 12 months' follow-up were included. Post-procedure changes in keratometry readings (Flat meridian: K1; steep meridian: K2), central corneal thickness (CCT), best spectacle-corrected visual acuity (BSCVA), and manifest refraction spherical equivalent (MRSE) were analysed.ResultsA total of 42 eyes were included. In all, 21 eyes had accelerated CXL (20.5±5.5 months' follow-up) and 21 eyes had conventional CXL group (20.2±5.6 months' follow-up). In the accelerated CXL group, a significant reduction in K2 (P=0.02), however no significant change in K1 (P=0.35) and CCT (P=0.62) was noted. In the conventional CXL group, a significant reduction was seen in K1 (P=0.01) and K2 (P=0.04), but not in CCT (P=0.95). Although both groups exhibited significant reductions in K2 readings, no noteworthy differences were noted between them (P=0.36). Improvements in BSCVA (accelerated CXL; P=0.22 and conventional CXL; P=0.20) and MRSE (accelerated CXL; P=0.97 and conventional CXL; P=0.54) were noted, however were not significant in either group.ConclusionAccelerated and conventional CXL appear to be effective procedures for stabilising progressive keratoconus in the long-term.

  4. Synthesis of novel chalcone derivatives by conventional and microwave irradiation methods and their pharmacological activities

    Directory of Open Access Journals (Sweden)

    Mohammed Rayees Ahmad

    2016-09-01

    Full Text Available Chalcones are abundant in edible plants and are considered to be the precursors of flavonoids and isoflavonoids. Chalcones belong to an important class of flavonoids, which may be prepared by Claisen–Schmidt condensation. They possess a wide range of biological activities and industrial applications. The cytotoxicity against tumour cell lines may be the result of disruption of the cell cycle, inhibition of angiogenesis, interference with p53-MDM2 interaction, mitochondrial uncoupling or induction of apoptosis. Chalcones are synthesized by conventional and microwave assisted synthesis methods. By microwave assisted synthesis, a considerable increase in the reaction rate has been observed and that too, with better yields. The compounds have been screened for cytotoxic activity and antioxidant activity.

  5. Tailings dams from the perspective of conventional dam engineering

    International Nuclear Information System (INIS)

    Szymanski, M.B.

    1999-01-01

    A guideline intended for conventional dams such as hydroelectric, water supply, flood control, or irrigation is used sometimes for evaluating the safety of a tailings dam. Differences between tailings dams and conventional dams are often substantial and, as such, should not be overlooked when applying the techniques or safety requirements of conventional dam engineering to tailings dams. Having a dam safety evaluation program developed specifically for tailings dams is essential, if only to reduce the chance of potential errors or omissions that might occur when relying on conventional dam engineering practice. This is not to deny the merits of using the Canadian Dam Safety Association Guidelines (CDSA) and similar conventional dam guidelines for evaluating the safety of tailings dams. Rather it is intended as a warning, and as a rationale underlying basic requirement of tailings dam emgineering: specific experience in tailings dams is essential when applying conventional dam engineering practice. A discussion is included that focuses on the more remarkable tailings dam safety practics. It is not addressed to a technical publications intended for such dams, or significantly different so that the use of conventional dam engineering practice would not be appropriate. The CDSA Guidelines were recently revised to include tailings dams. But incorporating tailings dams into the 1999 revision of the CDSA Guidelines is a first step only - further revision is necessary with respect to tailings dams. 11 refs., 2 tabs

  6. Treatment of waste water by a combined technique of radiation and conventional method

    International Nuclear Information System (INIS)

    Sakumoto, A.; Miyata, T.

    1984-01-01

    Treatment of waste water by radiation in combination with a conventional method such as biological oxidation, coagulation with Fe 2 (SO 4 ) 3 , and ozonation has been studied for reducing necessary dose. Ethylene glycol ethers, polyoxyethylene n-nonyl phenyl ether (NPE), polyvinyl alcohol (PVA), ethylene glycol, phenol, and oxalic acid were used as a model pollutant. The combined use of radiation and biological oxidation markedly improved the removal of TOC in aqueous oxygenated solution of ethylene glycol ethers. The combined use of radiation and coagulation had remarkable effects on the reduction of TOC in aqueous deoxygenated solution of NPE or PVA. The simultaneous use of radiation and ozone gave a synergistic effect on oxidative degradation of organic pollutants. The synergistic effect was suggested to arise from chain reactions having a powerful oxidizing agent (OH radical). The rate of TOC removal by the process depended on dose rate. Aqueous solution of 150 mg/l oxalic acid was treated by the combined use of electron beams and ozone using a new type of irradiation vessel to reduce TOC with G(-TOC) of 87 at 2.3 x 10 7 rad/h. The simultaneous use of radiation and ozone is superior to the removal of TOC by other combined methods and can be applied irrespective of the type of organic matter. (author)

  7. Guidelines regarding National Reports under the Convention on Nuclear Safety

    International Nuclear Information System (INIS)

    2011-01-01

    These guidelines, established by the Contracting Parties pursuant to Article 22 of the Convention on Nuclear Safety (hereinafter called the Convention), are intended to be read in conjunction with the text of the Convention. Their purpose is to provide guidance to the Contracting Parties regarding material that it may be useful to include in the National Reports required under Article 5 and thereby to facilitate the most efficient review of implementation by the Contracting Parties of their obligations under the Convention [es

  8. Guidelines regarding National Reports under the Convention on Nuclear Safety

    International Nuclear Information System (INIS)

    2011-01-01

    These guidelines, established by the Contracting Parties pursuant to Article 22 of the Convention on Nuclear Safety (hereinafter called the Convention), are intended to be read in conjunction with the text of the Convention. Their purpose is to provide guidance to the Contracting Parties regarding material that it may be useful to include in the National Reports required under Article 5 and thereby to facilitate the most efficient review of implementation by the Contracting Parties of their obligations under the Convention

  9. International practice patterns and factors associated with non-conventional hemodialysis utilization

    Directory of Open Access Journals (Sweden)

    Allen Nathan

    2011-12-01

    Full Text Available Abstract Background The purpose of our study was to determine characteristics that influence the utilization of non-conventional hemodialysis (NCHD therapies and its subtypes (nocturnal (NHD, short daily (SDHD, long conventional (LCHD and conventional hemodialysis (CHD as well as provider attitudes regarding the evidence for NCHD use. Methods An international cohort of subscribers of a nephrology education website http://www.nephrologynow.com was invited to participate in an online survey. Non-conventional hemodialysis was defined as any forms of hemodialysis delivered > 3 treatments per week and/or > 4 hours per session. NHD and SDHD included both home and in-centre. Respondents were categorized as CHD if their centre only offered conventional thrice weekly hemodialysis. Variables associated with NCHD and its subtypes were determined using multivariate logistic regression analysis. The survey assessed multiple domains regarding NCHD including reasons for initiating and discontinuing, for not offering and attitudes regarding evidence. Results 544 surveys were completed leading to a 15.6% response rate. The final cohort was limited to 311 physicians. Dialysis modalities utilized among the respondents were as follows: NCHD194 (62.4%, NHD 83 (26.7%, SDHD 107 (34.4%, LCHD 81 (26% and CHD 117 (37.6%. The geographic regions of participants were as follows: 11.9% Canada, 26.7% USA, 21.5% Europe, 6.1% Australia/New Zealand, 10% Africa/Middle East, 10.9% Asia and 12.9% South America. Variables associated with NCHD utilization included NCHD training (OR 2.47 CI 1.25-4.16, government physician reimbursement (OR 2.66, CI 1.11-6.40, practicing at an academic centre (OR 2.28 CI 1.25-4.16, higher national health care expenditure and number of ESRD patients per centre. Hemodialysis providers with patients on NCHD were significantly more likely to agree with the statements that NCHD improves quality of life, improves nutritional status, reduces EPO requirements

  10. Financing options to develop non-conventional reserves

    International Nuclear Information System (INIS)

    Tricoli, C.

    1997-01-01

    The economics of non-conventional natural gas reserves such as coalbed methane, gas shales and tight gas were discussed, with special reference to financing options to develop such reserves. Before 1992, tax credits were used to stimulate the development of non-conventional gas. The requirements for section 29 tax credits, the objectives of investors and producers, and the methods used to monetize section 29 tax credits, such as public royalty trusts, partnership structures, and up-front payment mechanisms were described. The capital gains implications of gas sales were also reviewed. It was noted that in the absence of tax credits, financing the development of non-conventional reserves must undergo the same economic scrutiny as any other oil and gas project

  11. An elemental concentration open source database for Hogdahl-Convention and Westcott-Formalism based on K0-INAA method in Malaysia

    International Nuclear Information System (INIS)

    Yavar, A.R.; Sukiman Sarmani; Tan, C.Y.; Rafie, N.N.; Lim, S.W.E.; Khoo, K.S.

    2012-01-01

    An electronic database has been developed and implemented for K 0 -INAA method in Malaysia. Databases are often developed according to national requirements. This database contains constant nuclear data for k 0 -INAA method. Hogdahl-convention and Westcott-formalism as 3 separate command user interfaces. It has been created using Microsoft Access 2007 under a Windows operating system. This database saves time and the quality of results can be assured when the calculation of neutron flux parameters and concentration of elements by k 0 -INAA method are utilised. An evaluation of the database was conducted by IAEA Soil7 where the results published which showed a high level of consistency. (Author)

  12. A new international convention against terrorism: the International Convention for the Suppression of Acts of Nuclear Terrorism. Full text in French, English and Spanish. Introduction to the main elements of the convention

    International Nuclear Information System (INIS)

    Laborde, Jean-Paul; )

    2005-01-01

    The International Convention for the Suppression of Acts of Nuclear Terrorism is a 2005 United Nations treaty designed to criminalize acts of nuclear terrorism and to promote police and judicial cooperation to prevent, investigate and punish those acts. As of September 2016, the convention has 115 signatories and 106 state parties, including the nuclear powers China, France, India, Russia, the United Kingdom, and the United States. The Convention covers a broad range of acts and possible targets, including nuclear power plants and nuclear reactors; covers threats and attempts to commit such crimes or to participate in them, as an accomplice; stipulates that offenders shall be either extradited or prosecuted; encourages States to cooperate in preventing terrorist attacks by sharing information and assisting each other in connection with criminal investigations and extradition proceedings; and, deals with both crisis situations, assisting States to solve the situations and post-crisis situations by rendering nuclear material safe through the International Atomic Energy Agency (IAEA)

  13. A review of conventional explosives detection using active neutron interrogation

    International Nuclear Information System (INIS)

    Whetstone, Z.D.; Kearfott, K.J.

    2014-01-01

    Conventional explosives are relatively easy to obtain and may cause massive harm to people and property. There are several tools employed by law enforcement to detect explosives, but these can be subverted. Active neutron interrogation is a viable alternative to those techniques, and includes: fast neutron analysis, thermal neutron analysis, pulsed fast/thermal neutron analysis, neutron elastic scatter, and fast neutron radiography. These methods vary based on neutron energy and radiation detected. A thorough review of the principles behind, advantages, and disadvantages of the different types of active neutron interrogation is presented. (author)

  14. Neutron activation analysis of archaeological artifacts using the conventional relative method: a realistic approach for analysis of large samples

    International Nuclear Information System (INIS)

    Bedregal, P.S.; Mendoza, A.; Montoya, E.H.; Cohen, I.M.; Universidad Tecnologica Nacional, Buenos Aires; Oscar Baltuano

    2012-01-01

    A new approach for analysis of entire potsherds of archaeological interest by INAA, using the conventional relative method, is described. The analytical method proposed involves, primarily, the preparation of replicates of the original archaeological pottery, with well known chemical composition (standard), destined to be irradiated simultaneously, in a well thermalized external neutron beam of the RP-10 reactor, with the original object (sample). The basic advantage of this proposal is to avoid the need of performing complicated effect corrections when dealing with large samples, due to neutron self shielding, neutron self-thermalization and gamma ray attenuation. In addition, and in contrast with the other methods, the main advantages are the possibility of evaluating the uncertainty of the results and, fundamentally, validating the overall methodology. (author)

  15. Deviation Value for Conventional X-ray in Hospitals in South Sulawesi Province from 2014 to 2016

    Science.gov (United States)

    Bachtiar, Ilham; Abdullah, Bualkar; Tahir, Dahlan

    2018-03-01

    This paper describes the conventional X-ray machine parameters tested in the region of South Sulawesi from 2014 to 2016. The objective of this research is to know deviation of every parameter of conventional X-ray machine. The testing parameters were analyzed by using quantitative methods with participatory observational approach. Data collection was performed by testing the output of conventional X-ray plane using non-invasive x-ray multimeter. The test parameters include tube voltage (kV) accuracy, radiation output linearity, reproducibility and radiation beam value (HVL) quality. The results of the analysis show four conventional X-ray test parameters have varying deviation spans, where the tube voltage (kV) accuracy has an average value of 4.12%, the average radiation output linearity is 4.47% of the average reproducibility of 0.62% and the averaged of the radiation beam (HVL) is 3.00 mm.

  16. Transfer of pharmacopoeial liquid chromatography reversedphase methods for determination of related compounds in diclofenac sodium and metamizole sodium from conventional to core-shell column

    Directory of Open Access Journals (Sweden)

    Katerina Brezovska

    2015-04-01

    Full Text Available Core-shell silica particles were developed as a new material for chromatographic stationary phases in order to provide fast and high efficiency separations of small and large molecules and complex samples, at pressures compatible with conventional HPLC equipment. The aim of our work was to show the applicability of the HPLC columns based on a core-shell technology for determination of related substances in diclofenac sodium and in metamizole sodium using the methods described in the corresponding monographs of the European pharmacopoeia. The obtained results have shown that the proposed methods can be successfully transferred on core shell column, with suitable adjustment of injection volume and flow rate. The advantage of using core-shell column is fast and highly efficient separation on conventional HPLC equipment with increased sensitivity of the method and high throughput of the analysis, providing enhanced lab productivity and reduced costs.

  17. Shared and task-specific muscle synergies of Nordic walking and conventional walking.

    Science.gov (United States)

    Boccia, G; Zoppirolli, C; Bortolan, L; Schena, F; Pellegrini, B

    2018-03-01

    Nordic walking is a form of walking that includes a poling action, and therefore an additional subtask, with respect to conventional walking. The aim of this study was to assess whether Nordic walking required a task-specific muscle coordination with respect to conventional walking. We compared the electromyographic (EMG) activity of 15 upper- and lower-limb muscles of 9 Nordic walking instructors, while executing Nordic walking and conventional walking at 1.3 ms -1 on a treadmill. Non-negative matrix factorization method was applied to identify muscle synergies, representing the spatial and temporal organization of muscle coordination. The number of muscle synergies was not different between Nordic walking (5.2 ± 0.4) and conventional walking (5.0 ± 0.7, P = .423). Five muscle synergies accounted for 91.2 ± 1.1% and 92.9 ± 1.2% of total EMG variance in Nordic walking and conventional walking, respectively. Similarity and cross-reconstruction analyses showed that 4 muscle synergies, mainly involving lower-limb and trunk muscles, are shared between Nordic walking and conventional walking. One synergy acting during upper limb propulsion is specific to Nordic walking, modifying the spatial organization and the magnitude of activation of upper limb muscles compared to conventional walking. The inclusion of the poling action in Nordic walking does not increase the complexity of movement control and does not change the coordination of lower limb muscles. This makes Nordic walking a physical activity suitable also for people with low motor skill. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Comparison of conventional liquid chromatography-tandem mass spectrometry versus microflow liquid chromatography-tandem mass spectrometry within the framework of full method validation for simultaneous quantification of 40 antidepressants and neuroleptics in whole blood.

    Science.gov (United States)

    Steuer, Andrea E; Poetzsch, Michael; Koenig, Magdalena; Tingelhoff, Eva; Staeheli, Sandra N; Roemmelt, Andreas T; Kraemer, Thomas

    2015-02-13

    Microflow liquid chromatography (MFLC) coupled to mass spectrometry (MS) is claimed to improve analysis throughput, reduce matrix effects and lower mobile phase consumption. This statement was checked within the framework of method validation of a multi-analyte procedure in clinical and forensic toxicology employing MFLC-MS/MS and conventional LC-MS/MS. 200 μL whole blood were spiked with 50 μL internal standard mixture and extracted by protein precipitation. The concentrated extract was separated into two vials. One was analyzed using a Thermo Fisher Ultimate liquid chromatography system coupled to an ABSciex 5500 QTrap mass spectrometer (LC-MS/MS) and one by an ABSciex Eksigent Microflow LC system coupled to an ABSciex 4500 linear ion trap quadrupole MS (MFLC-MS/MS). Both methods were fully validated and compared in terms of selectivity, stability, limits, calibration model, recovery (RE), matrix effects (ME), bias, imprecision and beta tolerance interval for 40 antidepressants and neuroleptics including 9 metabolites. Both methods had comparable LODs, LOQs and calibration models with some exceptions. The MFLC system showed slightly higher coefficients of variation (CVs) in the RE experiments. ME were reproducible in both systems but with lower CVs in the conventional LC system. Acceptance criteria for imprecision and bias were fulfilled for 32 analytes on the LC and for 28 analytes on the MFLC system. Beta tolerance intervals indicated better reproducibility in terms of narrower intervals for the conventional LC system. The advantages of the MFLC system were low mobile phase consumption, short run time, and better peak separation. The systems were comparable in terms of peak interference, LOD, ME, bias and imprecision. The advantages of the conventional LC system were more data points per peak, linear calibration models, stable retention times and better beta tolerance intervals. Due to higher robustness, the conventional LC system was finally chosen for

  19. Dental Students' Perceptions of Digital and Conventional Impression Techniques: A Randomized Controlled Trial.

    Science.gov (United States)

    Zitzmann, Nicola U; Kovaltschuk, Irina; Lenherr, Patrik; Dedem, Philipp; Joda, Tim

    2017-10-01

    The aim of this randomized controlled trial was to analyze inexperienced dental students' perceptions of the difficulty and applicability of digital and conventional implant impressions and their preferences including performance. Fifty undergraduate dental students at a dental school in Switzerland were randomly divided into two groups (2×25). Group A first took digital impressions in a standardized phantom model and then conventional impressions, while the procedures were reversed for Group B. Participants were asked to complete a VAS questionnaire (0-100) on the level of difficulty and applicability (user/patient-friendliness) of both techniques. They were asked which technique they preferred and perceived to be more efficient. A quotient of "effective scan time per software-recorded time" (TRIOS) was calculated as an objective quality indicator for intraoral optical scanning (IOS). The majority of students perceived IOS as easier than the conventional technique. Most (72%) preferred the digital approach using IOS to take the implant impression to the conventional method (12%) or had no preference (12%). Although total work was similar for males and females, the TRIOS quotient indicated that male students tended to use their time more efficiently. In this study, dental students with no clinical experience were very capable of acquiring digital tools, indicating that digital impression techniques can be included early in the dental curriculum to help them catch up with ongoing development in computer-assisted technologies used in oral rehabilitation.

  20. Strategies for Solving Potential Problems Associated with Laboratory Diffusion and Batch Experiments - Part 1: An Overview of Conventional Test Methods

    International Nuclear Information System (INIS)

    Zhang, M.; Takeda, M.; Nakajima, H.

    2006-01-01

    Laboratory diffusion testing as well as batch experiments are well established and widely adopted techniques for characterizing the diffusive and adsorptive properties of geological, geotechnical, and synthetic materials in both scientific and applied fields, including geological disposal of radioactive waste. Although several types of diffusion test, such as the through- diffusion test, in-diffusion test, out-diffusion test, and column test, are currently available, different methods may have different advantages and disadvantages. In addition, traditional methods may have limitations, such as the need for relatively long test times, cumbersome test procedures, and the possibility of errors due to differences between analytical assumptions and actual test conditions. Furthermore, traditional batch experiments using mineral powders are known to overestimate the sorption coefficient. In part 1 of this report, we present a brief overview of laboratory diffusion and batch experiments. The advantages, disadvantages, limitations, and/or potential problems associated with individual tests were compared and summarized. This comprehensive report will provide practical references for reviewing the results obtained from relevant experiments, especially from the viewpoint of regulation. To solve and/or eliminate the potential problems associated with conventional methods, and to obtain the diffusion coefficient and rock capacity factor from a laboratory test both rapidly and accurately, part 2 of this study discusses possible strategies involving the development of rigorous solutions to some relevant test methods, and sensitivity analyses for the related tests that may be helpful to judge the accuracy of the two parameters to be determined from individual tests. (authors)

  1. Conventional versus combined apgar scores in neonatal asphyxia: a prospective study

    Directory of Open Access Journals (Sweden)

    Amir Kamal Hardani

    2015-01-01

    Conclusion: In asphyxiated neonates sensitivity and specificity of combined apgar were more than conventional apgar. With respect to this study, better assessment could be achieved by combined apgar score method instead of conventional Apgar.

  2. Imaging in hematology. Part 1: Ultrasonography and conventional radiology

    International Nuclear Information System (INIS)

    Zhechev, Y.

    2003-01-01

    Applications of conventional ultrasonography techniques (B-mode or real time) in oncohematology are presented. The newer adaptations (in particular colour Doppler) provide incremental advantages that support their inclusion in the imaging techniques available to modern hematology. Conventional radiologic studies include chest and bone X-ray, gastrointestinal contrast examination and bipedal lymphangiography

  3. Compact Ignition Tokamak conventional facilities optimization

    International Nuclear Information System (INIS)

    Commander, J.C.; Spang, N.W.

    1987-01-01

    A high-field ignition machine with liquid-nitrogen-cooled copper coils, designated the Compact Ignition Tokamak (CIT), is proposed for the next phase of the United States magnetically confined fusion program. A team of national laboratory, university, and industrial participants completed the conceptual design for the CIT machine, support systems and conventional facilities. Following conceptual design, optimization studies were conducted with the goal of improving machine performance, support systems design, and conventional facilities configuration. This paper deals primarily with the conceptual design configuration of the CIT conventional facilities, the changes that evolved during optimization studies, and the revised changes resulting from functional and operational requirements (F and ORs). The CIT conventional facilities conceptual design is based on two premises: (1) satisfaction of the F and ORs developed in the CIT building and utilities requirements document, and (2) the assumption that the CIT project will be sited at the Princeton Plasma Physics Laboratory (PPPL) in order that maximum utilization can be made of existing Tokamak Fusion Test Reactor (TFTR) buildings and utilities. The optimization studies required reevaluation of the F and ORs and a second look at TFTR buildings and utilities. Some of the high-cost-impact optimization studies are discussed, including the evaluation criteria for a change from the conceptual design baseline configuration. The revised conventional facilities configuration are described and the estimated cost impact is summarized

  4. Comparison of Polyacetylene Content in Organically and Conventionally Grown Carrots Using a Fast Ultrasonic Liquid Extraction Method

    DEFF Research Database (Denmark)

    Søltoft, Malene; Eriksen, Morten Rosbjørn; Träger, Anne Wibe Brændholt

    2010-01-01

    deviations (RSDs) of 2.3−3.6%], and recovery (93% of falcarindiol) of the polyacetylenes. The applicability of the method was documented by comparative analyses of carrots grown organically or conventionally in a 2 year field trial study. The average concentrations of falcarindiol, falcarindiol-3-acetate......, and falcarinol in year 1 were 222, 30, and 94 μg of falcarindiol equiv/g of dry weight, respectively, and 3−15% lower in year 2. The concentrations were not significantly influenced by the growth system, but a significant year−year variation was observed for falcarindiol-3-acetate....

  5. An in vitro comparison of photogrammetric and conventional complete-arch implant impression techniques.

    Science.gov (United States)

    Bergin, Junping Ma; Rubenstein, Jeffrey E; Mancl, Lloyd; Brudvik, James S; Raigrodski, Ariel J

    2013-10-01

    Conventional impression techniques for recording the location and orientation of implant-supported, complete-arch prostheses are time consuming and prone to error. The direct optical recording of the location and orientation of implants, without the need for intermediate transfer steps, could reduce or eliminate those disadvantages. The objective of this study was to assess the feasibility of using a photogrammetric technique to record the location and orientation of multiple implants and to compare the results with those of a conventional complete-arch impression technique. A stone cast of an edentulous mandibular arch containing 5 implant analogs was fabricated to create a master model. The 3-dimensional (3D) spatial orientations of implant analogs on the master model were measured with a coordinate measuring machine (CMM) (control). Five definitive casts were made from the master model with a splinted impression technique. The positions of the implant analogs on the 5 casts were measured with a NobelProcera scanner (conventional method). Prototype optical targets were attached to the master model implant analogs, and 5 sets of images were recorded with a digital camera and a standardized image capture protocol. Dimensional data were imported into commercially available photogrammetry software (photogrammetric method). The precision and accuracy of the 2 methods were compared with a 2-sample t test (α=.05) and a 95% confidence interval. The location precision (standard error of measurement) for CMM was 3.9 µm (95% CI 2.7 to 7.1), for photogrammetry, 5.6 µm (95% CI 3.4 to 16.1), and for the conventional method, 17.2 µm (95% CI 10.3 to 49.4). The average measurement error was 26.2 µm (95% CI 15.9 to 36.6) for the conventional method and 28.8 µm (95% CI 24.8 to 32.9) for the photogrammetric method. The overall measurement accuracy was not significantly different when comparing the conventional to the photogrammetric method (mean difference = -2.6 µm, 95% CI

  6. Late toxicities after conventional radiation therapy alone for nasopharyngeal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Tuan, Jeffrey Kit Loong, E-mail: ntrtkl@nccs.com.sg [Department of Radiation Oncology, National Cancer Centre Singapore (Singapore); Ha, Tam Cam [Division of Clinical Trials and Epidemiological Sciences, National Cancer Centre Singapore (Singapore); Duke-NUS Graduate Medical School (Singapore); Ong, Whee Sze [Division of Clinical Trials and Epidemiological Sciences, National Cancer Centre Singapore (Singapore); Siow, Tian Rui [Department of Radiation Oncology, National Cancer Centre Singapore (Singapore); Tham, Ivan Weng Keong [National University Health System Singapore (Singapore); Yap, Swee Peng; Tan, Terence Wee Kiat; Chua, Eu Tiong; Fong, Kam Weng [Department of Radiation Oncology, National Cancer Centre Singapore (Singapore); Wee, Joseph Tien Seng [Department of Radiation Oncology, National Cancer Centre Singapore (Singapore); Division of Clinical Trials and Epidemiological Sciences, National Cancer Centre Singapore (Singapore); Duke-NUS Graduate Medical School (Singapore)

    2012-09-15

    Background and purpose: We sought to evaluate the nature and frequency of late toxicities in a cohort of nasopharyngeal cancer (NPC) patients treated with conventional radiotherapy alone. Methods and materials: Seven-hundred and ninety-six consecutive NPC patients treated using conventional radiotherapy at a single center from 1992 to 1995 were retrospectively analyzed. Patients with histology proven, completely staged, Stage I-IVB World Health Organization Type I-III NPC and completed radical radiotherapy were included. Patients with incomplete staging investigations, distant metastases at diagnosis, previous treatment, and incomplete radiotherapy were excluded. Radiotherapy-related complications were categorized using the RTOG Late Radiation Morbidity Scoring Criteria. Results: Median follow-up was 7.2 years. The 5-year overall survival and disease free survival were 69% and 56%, respectively, and the corresponding 10-year rates were 52% and 44%. Among 771 patients with at least 3 months of follow-up post treatment, 565 (73%) developed RT-related complications. Diagnosed neurological complications were cranial nerve palsies (n = 70; 9%), temporal lobe necrosis (n = 37; 5%), Lhermitte's syndrome (n = 7; 1%), and brachial plexopathy (n = 2; 0.3%). Non-neurological complications included xerostomia (n = 353; 46%), neck fibrosis (n = 169; 22%), hypo-pituitarism (n = 48; 6%), hearing loss (n = 120; 16%), dysphagia (n = 116; 15%), otorrhea (n = 101; 13%), tinnitus (n = 94; 12%), permanent tube feeding (n = 61; 8%), trismus (n = 45; 6%), second malignancies within treatment field (n = 17; 2%), and osteo-radionecrosis (n = 13; 2%). Conclusions: While radiotherapy is curative in NPC, many patients suffer significant late treatment morbidities with conventional radiotherapy techniques.

  7. Late toxicities after conventional radiation therapy alone for nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Tuan, Jeffrey Kit Loong; Ha, Tam Cam; Ong, Whee Sze; Siow, Tian Rui; Tham, Ivan Weng Keong; Yap, Swee Peng; Tan, Terence Wee Kiat; Chua, Eu Tiong; Fong, Kam Weng; Wee, Joseph Tien Seng

    2012-01-01

    Background and purpose: We sought to evaluate the nature and frequency of late toxicities in a cohort of nasopharyngeal cancer (NPC) patients treated with conventional radiotherapy alone. Methods and materials: Seven-hundred and ninety-six consecutive NPC patients treated using conventional radiotherapy at a single center from 1992 to 1995 were retrospectively analyzed. Patients with histology proven, completely staged, Stage I–IVB World Health Organization Type I–III NPC and completed radical radiotherapy were included. Patients with incomplete staging investigations, distant metastases at diagnosis, previous treatment, and incomplete radiotherapy were excluded. Radiotherapy-related complications were categorized using the RTOG Late Radiation Morbidity Scoring Criteria. Results: Median follow-up was 7.2 years. The 5-year overall survival and disease free survival were 69% and 56%, respectively, and the corresponding 10-year rates were 52% and 44%. Among 771 patients with at least 3 months of follow-up post treatment, 565 (73%) developed RT-related complications. Diagnosed neurological complications were cranial nerve palsies (n = 70; 9%), temporal lobe necrosis (n = 37; 5%), Lhermitte’s syndrome (n = 7; 1%), and brachial plexopathy (n = 2; 0.3%). Non-neurological complications included xerostomia (n = 353; 46%), neck fibrosis (n = 169; 22%), hypo-pituitarism (n = 48; 6%), hearing loss (n = 120; 16%), dysphagia (n = 116; 15%), otorrhea (n = 101; 13%), tinnitus (n = 94; 12%), permanent tube feeding (n = 61; 8%), trismus (n = 45; 6%), second malignancies within treatment field (n = 17; 2%), and osteo-radionecrosis (n = 13; 2%). Conclusions: While radiotherapy is curative in NPC, many patients suffer significant late treatment morbidities with conventional radiotherapy techniques.

  8. A comparison of conventional and retrospective measures of change in symptoms after elective surgery

    Directory of Open Access Journals (Sweden)

    Dörning Hans

    2011-04-01

    Full Text Available Abstract Background Measuring change is fundamental to evaluations, health services research and quality management. To date, the Gold-Standard is the prospective assessment of pre- to postoperative change. However, this is not always possible (e.g. in emergencies. Instead a retrospective approach to the measurement of change is one alternative of potential validity. In this study, the Gold-Standard 'conventional' method was compared with two variations of the retrospective approach: a perceived-change design (model A and a design that featured observed follow-up minus baseline recall (model B. Methods In a prospective longitudinal observational study of 185 hernia patients and 130 laparoscopic cholecystectomy patients (T0: 7-8 days pre-operative; T1: 14 days post-operative and T2: 6 months post-operative changes in symptoms (Hernia: 9 Items, Cholecystectomy: 8 Items were assessed at the three time points by patients and the conventional method was compared to the two alternatives. Comparisons were made regarding the percentage of missing values per questionnaire item, correlation between conventional and retrospective measurements, and the degree to which retrospective measures either over- or underestimated changes and time-dependent effects. Results Single item missing values in model A were more frequent than in model B (e.g. Hernia repair at T1: model A: 23.5%, model B: 7.9%. In all items and at both postoperative points of measurement, correlation of change between the conventional method and model B was higher than between the conventional method and model A. For both models A and B, correlation with the change calculated with the conventional method was higher at T1 than at T2. Compared to the conventional model both models A and B also overestimated symptom-change (i.e. improvement with similar frequency, but the overestimation was higher in model A than in model B. In both models, overestimation was lower at T1 than at T2 and lower

  9. HMB-45 reactivity in conventional uterine leiomyosarcomas.

    Science.gov (United States)

    Simpson, Karen W; Albores-Saavedra, Jorge

    2007-01-01

    We studied the human melanoma black-45 (HMB-45) reactivity in 25 uterine leiomyosarcomas including 23 conventional and 2 myxoid variants. Eleven tumors were poorly differentiated, and 14 were well to moderately differentiated. Nine uterine leiomyosarcomas labeled with HMB-45 in 10% or less of the tumor cells. Six were poorly differentiated and 3 were well differentiated. Our study indicates that 36% of conventional leiomyosarcomas focally express HMB-45. HMB-45 reactivity was more common in the poorly differentiated than in the well-differentiated group of leiomyosarcomas. In light of our findings and of those recently reported in the literature, we believe that the term PEComa should not be used for uterine leiomyosarcomas with clear cells or for conventional leiomyosarcomas that stain positively with HMB-45.

  10. In Vitro Comparative Study of the Working Length Determination with Radiovisiography and Conventional Radiography in Dilacerated Canals

    Directory of Open Access Journals (Sweden)

    Ali Bagherpour

    2015-06-01

    Full Text Available Introduction: The aim of this study was to compare digital and conventional radiography in determining the working length of dilacerated canals.Methods: Thirty nine human extracted single-rooted teeth with root curvature more than 35 degrees were included in this study. After access preparation, a file was inserted into the canal and advanced until the file tip was visualized at the foramen. With measurement of the file length using a millimeter ruler, true canal length was determined for each canal. Then, teeth were mounted in acrylic blocks and canal length was estimated by using on-screen digital radiography with both 3- and 6-clicks measurement and from conventional radiography by conforming a preserved file on the image of the root canal.Results: There were no significant differences in measurement accuracy between the true canal length and conventional radiographic length, but there were significant difference between both digital radiographic techniques with true canal length. There was no significant correlation between root curvature and canal length estimation error of studied methods.Conclusion: In dilacerated canals, the accuracy of determination of working length by using conventional radiography is higher than digital radiography

  11. Identification and quantification of genetically modified Moonshade carnation lines using conventional and TaqMan real-time polymerase chain reaction methods.

    Science.gov (United States)

    Li, Peng; Jia, Junwei; Bai, Lan; Pan, Aihu; Tang, Xueming

    2013-07-01

    Genetically modified carnation (Dianthus caryophyllus L.) Moonshade was approved for planting and commercialization in several countries from 2004. Developing methods for analyzing Moonshade is necessary for implementing genetically modified organism labeling regulations. In this study, the 5'-transgene integration sequence was isolated using thermal asymmetric interlaced (TAIL)-PCR. Based upon the 5'-transgene integration sequence, conventional and TaqMan real-time PCR assays were established. The relative limit of detection for the conventional PCR assay was 0.05 % for Moonshade using 100 ng total carnation genomic DNA, corresponding to approximately 79 copies of the carnation haploid genome, and the limits of detection and quantification of the TaqMan real-time PCR assay were estimated to be 51 and 254 copies of haploid carnation genomic DNA, respectively. These results are useful for identifying and quantifying Moonshade and its derivatives.

  12. Comparison of conventional straight and swan-neck straight catheters inserted by percutaneous method for continuous ambulatory peritoneal dialysis: a single-center study.

    Science.gov (United States)

    Singh, Shivendra; Prakash, Jai; Singh, R G; Dole, P K; Pant, Pragya

    2015-10-01

    To evaluate the incidence of mechanical and infectious complications of conventional straight catheter (SC) versus swan-neck straight catheter (SNSC) implanted by percutaneous method. We retrospectively analyzed 45 catheter insertions being done by percutaneous method from January 1, 2011, to May 31, 2014. SC was inserted in 24 patients, and SNSC was inserted in 21 patients. Baseline characteristics for the two groups were similar with respect to age, sex and diabetic nephropathy as the cause for end-stage renal disease. Incidence of mechanical and infectious complications in SNSC group was found to be low as compared to the SC group and was statistically significant (1 in 11.6 patient months vs. 1 in 14.4 patient months, p = 0.02). Catheter migration was found to be the most common mechanical complication (20 %), and peritonitis was found to be the most common infectious complication in conventional SC group (27 episodes in 420 patient months vs. 11 episodes in 333 patient months, p = 0.03). The incidence of exit site and tunnel infection rates revealed no difference between the groups. SNSC insertion by percutaneous method is associated with low mechanical and infectious complications.

  13. Comparison of conventional methods for diagnosis of visceral leishmaniasis in children of the Center-West Region of Brazil

    Directory of Open Access Journals (Sweden)

    Yvone M. Brustoloni

    Full Text Available In Brazil, sophisticated techniques currently employed for diagnosis of visceral leishmaniasis, such as polymerase chain reaction-based assays, are only available in major research centers, whereas conventional methods are still used in many areas where the disease occurs. In the state of Mato Grosso do Sul, in the country's Center-West Region, visceral leishmaniasis has recently emerged in many cities, and duration of the disease, from the onset of symptoms to diagnosis, has been short. Considering that results of diagnostic tests may depend on the phase of the disease, we compared direct examination of bone marrow aspirates (BMAs, BMA culture, and serology by Indirect Immunofluorescence Antibody Test (IFAT for diagnosis in children, according to time of evolution (30 days and to spleen size ( 5 cm at admission. Duration of the illness did not interfere with test positivity: direct smear examination and IFAT were positive in more than 80% of patients, as was culture in around 60%. Results of positive microscopy, however, where predominant in patients with larger spleens. Thanks to the association of traditional techniques, only a few patients had to begin a treatment trial without confirming the diagnosis. Conventional methods for diagnosis of visceral leishmaniasis are still indispensable in our region, and training professionals in basic techniques should be incremented. The highest sensitivity in laboratory diagnosis among the cases investigated was that obtained with a combination of BMA direct examination and IFAT, nearing 100%.

  14. Islamic and conventional equity index co-movement and volatility transmission: Evidence from Pakistan

    Directory of Open Access Journals (Sweden)

    Khalil Jebran

    2017-12-01

    Full Text Available This study investigates the Islamic and conventional Index integration over the period 3rd September, 2008 to 30th September, 2015. This study uses Johansen and Juselius cointegration method for exploring the long run association. The short run association is explored using VECM model. The volatility spillover dynamics is examined using the GARCH and EGARCH models. The robustness of the results is analyzed by using Granger causality method, Variance Decomposition method, and Impulse Response Function. The estimation results show significant long run and short run association between Islamic and Conventional index. Furthermore, this study finds asymmetric bidirectional volatility spillovers between Islamic and conventional index. The findings suggest that domestic investors have low diversification opportunities by adding both Islamic and conventional index in their portfolios. However, international investors can add one of the indices in their portfolios, in order to benefit from portfolio diversification. Keywords: Islamic index, Conventional index, EGARCH, GARCH, Pakistan

  15. Objective structured clinical examination "Death Certificate" station - Computer-based versus conventional exam format.

    Science.gov (United States)

    Biolik, A; Heide, S; Lessig, R; Hachmann, V; Stoevesandt, D; Kellner, J; Jäschke, C; Watzke, S

    2018-04-01

    One option for improving the quality of medical post mortem examinations is through intensified training of medical students, especially in countries where such a requirement exists regardless of the area of specialisation. For this reason, new teaching and learning methods on this topic have recently been introduced. These new approaches include e-learning modules or SkillsLab stations; one way to objectify the resultant learning outcomes is by means of the OSCE process. However, despite offering several advantages, this examination format also requires considerable resources, in particular in regards to medical examiners. For this reason, many clinical disciplines have already implemented computer-based OSCE examination formats. This study investigates whether the conventional exam format for the OSCE forensic "Death Certificate" station could be replaced with a computer-based approach in future. For this study, 123 students completed the OSCE "Death Certificate" station, using both a computer-based and conventional format, half starting with the Computer the other starting with the conventional approach in their OSCE rotation. Assignment of examination cases was random. The examination results for the two stations were compared and both overall results and the individual items of the exam checklist were analysed by means of inferential statistics. Following statistical analysis of examination cases of varying difficulty levels and correction of the repeated measures effect, the results of both examination formats appear to be comparable. Thus, in the descriptive item analysis, while there were some significant differences between the computer-based and conventional OSCE stations, these differences were not reflected in the overall results after a correction factor was applied (e.g. point deductions for assistance from the medical examiner was possible only at the conventional station). Thus, we demonstrate that the computer-based OSCE "Death Certificate" station

  16. The Conventional and Unconventional about Disability Conventions: A Reflective Analysis of United Nations Convention on the Rights of Persons with Disabilities

    Science.gov (United States)

    Umeasiegbu, Veronica I.; Bishop, Malachy; Mpofu, Elias

    2013-01-01

    This article presents an analysis of the United Nations Convention on the Rights of Persons with Disabilities (CRPD) in relation to prior United Nations conventions on disability and U.S. disability policy law with a view to identifying the conventional and also the incremental advances of the CRPD. Previous United Nations conventions related to…

  17. Preparation of nickel and Ni_3Sn nanoparticles via extension of conventional citric acid and ethylene diamine tetraacetic acid mediated sol–gel method

    International Nuclear Information System (INIS)

    Li, Pingyun; Deng, Guodong; Guo, Xiaode; Liu, Hongying; Jiang, Wei; Li, Fengsheng

    2016-01-01

    This work aims to extend the application field of sol–gel process from conventional oxides, carbides, sulfides to metallic nanocrystalline materials. Metallic ions were coordinated with chelating agents of citric acid (CA) and ethylene diamine tetraacetic acid (EDTA) in aqueous solution. Then the solutions were dried at 383 K, resulting in the formation of sol and gel. Heating treatments of dried gels were then carried out with protection of N_2 atmosphere. Ni and Ni_3Sn alloy nanoparticles were obtained by this sol–gel method in the range of 623–823 K. The as-prepared Ni and Ni_3Sn alloy nanoparticles have average grain sizes of 15 and 30 nm, and have face-centred-cubic (fcc) crystalline phase. Our results provide new insight into the application of conventional sol–gel method. - Graphical abstract: Sol–gel method is conventionally applied to prepare oxides, carbides, and sulfides. In this work, the application field of sol–gel method is extended to metallic nanoparticles. By using citric acid (CA) and ethylene diamine tetraacetic acid (EDTA) mediated sol–gel method, metallic Ni (a and c) and Ni_3Sn (b and d) alloy nanoparticles can be prepared when the heating treatments are performed under N_2 protecting atmosphere. The Ni and Ni_3Sn nanoparticles have face-centered-cubic (fcc) crystalline phase and ultrafine grain sizes. Diffraction peaks of (110) superstructure reflection plane of Ni_3Sn nanoparticles can also be observed in Figure b, which can be considered as direct evidence of formation of alloy crystalline phase by performing this sol–gel method. - Highlights: • Ni and Ni_3Sn alloy nanoparticles have been prepared by sol–gel processes. • Citric acid and ethylene diamine tetraacetic acid were applied as chelating agent. • Diffraction peak of superstructure reflection plane of Ni_3Sn was detected by XRD. • A novel strategy for preparation of alloy nanoparticles has been presented.

  18. 77 FR 59891 - Proposed Information Collection; Comment Request; Chemical Weapons Convention Declaration and...

    Science.gov (United States)

    2012-10-01

    ... Request; Chemical Weapons Convention Declaration and Report Handbook and Forms AGENCY: Bureau of Industry.... Abstract The Chemical Weapons Convention Implementation Act of 1998 and Commerce Chemical Weapons... Chemical Weapons Convention (CWC), an international arms control treaty. II. Method of Collection Submitted...

  19. Revision of the Paris Convention and the Brussels Supplementary Convention

    International Nuclear Information System (INIS)

    Busekist, Otto von.

    1977-01-01

    The Paris Convention and the Brussels Supplementary Convention have in substance remained unchanged since their adoption in 1960 and 1963, respectively. During that period, nuclear industry and technology have developed considerably while the financial and monetary bases of the Conventions have been shattered. The amounts of liability and compensation have been eroded by inflation, and the gold-based unit of account in which these amounts are expressed has lost its original meaning after the abolition of the official gold price. The question of revising the Conventions, in particular of raising those amounts and of replacing the unit of account, is therefore being studied by the Group of Governmental Experts on Third party Liability in the Field of Nuclear Energy of the OECD Nuclear Energy Agency. (auth.) [fr

  20. Comparative study between manual injection intraosseous anesthesia and conventional oral anesthesia

    OpenAIRE

    Peñarrocha-Oltra, David; Ata-Ali, Javier; Oltra-Moscardó, María J.; Peñarrocha-Diago, María; Peñarrocha, Miguel

    2011-01-01

    Objective: To compare intraosseous anesthesia (IA) with the conventional oral anesthesia techniques. Materials and methods: A simple-blind, prospective clinical study was carried out. Each patient underwent two anesthetic techniques: conventional (local infiltration and locoregional anesthetic block) and intraosseous, for res-pective dental operations. In order to allow comparison of IA versus conventional anesthesia, the two operations were similar and affected the same two teeth in opposite...

  1. Side effects and complications of intraosseous anesthesia and conventional oral anesthesia

    OpenAIRE

    Peñarrocha-Oltra, David; Ata-Ali, Javier; Oltra-Moscardó, María J.; Peñarrocha-Diago, María; Peñarrocha, Miguel

    2011-01-01

    Objective: To analyze the side effects and complications following intraosseous anesthesia (IA), comparing them with those of the conventional oral anesthesia techniques. Material and method: A simple-blind, prospective clinical study was carried out. Each patient underwent two anesthetic techniques: conventional (local infiltration and locoregional anesthetic block) and intraosseous, for respective dental operations. In order to allow comparison of IA versus conventional anesthesia, the two ...

  2. Clinical research on abdominal acupuncture plus conventional acupuncture for knee osteoarthritis

    DEFF Research Database (Denmark)

    Meng, Chang-rong; Fan, Li; Fu, Wen-bin

    2009-01-01

    OBJECTIVE: To probe the therapeutic effect of abdominal acupuncture plus conventional acupuncture on knee osteoarthritis. METHODS: PEMS3.1 software was used. The 105 patients with knee osteoarthritis were randomly divided into an abdominal acupuncture group, a conventional acupuncture group...... and a combined group (abdominal acupuncture plus conventional acupuncture). For the abdominal acupuncture group, the abdominal acupuncture was performed at Zhongwan (CV 12), Guanyuan (CV 4), Wailing (ST 26), Daheng (SP 15), Lower Rheumatism point and Qipang with needles retained for 30 minutes....... For the conventional acupuncture group, the acupuncture was practiced at Neixiyan (EX-LE4) and Dubi (ST 35) of the affected limb, Yanglingquan (GB 34), Liangqiu (ST 34), Xuehai (SP 10) and Xiyangguan (GB 33). For the combined group, both methods were applied. Treatment was given once a day, 6 times a week, for 4 weeks...

  3. Guidelines regarding National Reports under the Convention on Nuclear Safety

    International Nuclear Information System (INIS)

    1999-01-01

    These guidelines, established by the Contracting Parties pursuant to Article 22 of the Convention, are intended to be read in conjunction with the text of the Convention. Their purpose is to provide guidance to the Contracting Parties regarding material which it may be useful to include in the national reports required by Article 5 and thereby to facilitate the most efficient review of implementation by the Contracting Parties of their obligations under the Convention

  4. Guidelines regarding national reports under the convention on nuclear safety

    International Nuclear Information System (INIS)

    1998-01-01

    These guidelines, established by the Contracting Parties pursuant to Article 22 of the Convention, are intended to be read in conjunction with the text of the Convention. Their purpose is to provide guidance to the Contracting Parties regarding material which it may be useful to include in the national reports required by Article 5 and thereby to facilitate the most efficient review of implementation by the Contracting Parties of their obligations under the Convention

  5. Guidelines regarding National Reports under the Convention on Nuclear Safety

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-10-15

    These guidelines, established by the Contracting Parties pursuant to Article 22 of the Convention, are intended to be read in conjunction with the text of the Convention. Their purpose is to provide guidance to the Contracting Parties regarding material which it may be useful to include in the national reports required by Article 5 and thereby to facilitate the most efficient review of implementation by the Contracting Parties of their obligations under the Convention.

  6. Antioxidant activity in selected Slovenian organic and conventional crops

    Directory of Open Access Journals (Sweden)

    Manca KNAP

    2015-12-01

    Full Text Available The demand for organically produced food is increasing. There is widespread belief that organic food is substantially healthier and safer than conventional food. According to literature organic food is free of phytopharmaceutical residues, contain less nitrates and more antioxidants. The aim of the present study was to verify if there are any differences in the antioxidant activity between selected Slovenian organic and conventional crops. Method of DPPH (2,2-diphenyl-1-picryhydrazyl was used to determine the antioxidant activity of 16 samples from organic and conventional farms. The same varieties of crops were analysed. DPPH method was employed to measure the antioxidant activity of polar antioxidants (AAp and antioxidant activity of fraction in ethyl acetate soluble antioxidants (EA AA. Descriptive statistics and variance analysis were used to describe differences between farming systems. Estimated differences between interactions for the same crop and different farming practice were mostly not statistically significant except for the AAp for basil and beetroot. Higher statistically significant values were estimated for conventional crops. For the EA AA in broccoli, cucumber, rocket and cherry statistically significant higher values were estimated for organic production.

  7. Radiopacity of restorative composites by conventional radiography and digital images with different resolutions

    Energy Technology Data Exchange (ETDEWEB)

    Dantas, Raquel Venancio; Samento, Hugo Ramalho [Graduate Program in Dentistry, Federal University of Pelotas, Pelotas (Brazil); Duarte, Rosangela Marques; Raso, Sonia Saeger Meireles Monte; De Andrade Ana Karina Maciel; Anjos-Pontual Maria Luiza Dos [Dept. of Operative Dentistry, Federal University of Paraiba, Pelotas (Brazil)

    2013-09-15

    This study was performed to evaluate and compare the radiopacity of dentin, enamel, and 8 restorative composites on conventional radiograph and digital images with different resolutions. Specimens were fabricated from 8 materials and human molars were longitudinally sectioned 1.0 mm thick to include both enamel and dentin. The specimens and tooth sections were imaged by conventional radiograph using 4 sized intraoral film and digital images were taken in high speed and high resolution modes using a phosphor storage plate. Densitometric evaluation of the enamel, dentin, restorative materials, a lead sheet, and an aluminum step wedge was performed on the radiographic images. For the evaluation, the Al equivalent (mm) for each material was calculated. The data were analyzed using one-way ANOVA and Tukey's test (p<0.05), considering the material factor and then the radiographic method factor, individually. The high speed mode allowed the highest radiopacity, while the high resolution mode generated the lowest values. Furthermore, the high resolution mode was the most efficient method for radiographic differentiation between restorative composites and dentin. The conventional radiograph was the most effective in enabling differentiation between enamel and composites. The high speed mode was the least effective in enabling radiographic differentiation between the dental tissues and restorative composites. The high speed mode of digital imaging was not effective for differentiation between enamel and composites. This made it less effective than the high resolution mode and conventional radiographs. All of the composites evaluated showed radiopacity values that fit the ISO 4049 recommendations.

  8. Clinical comparative study between the use of lasers and conventional methods of diagnosis and treatment in deciduous teeth with presence of carious lesion

    International Nuclear Information System (INIS)

    Pulga, Fabiane Galvao

    2001-01-01

    The aim of this work was to evaluate the efficiency of deciduous tooth cavity preparation by the Er:YAG laser in comparison with the conventional burr rotary instrument. Besides, we have used the laser fluorescence technique (DIAGNOdent equipment) for diagnosis and compared it to the usual tactile and visual examination as well as X-ray diagnosis. For this purpose, 20 chronic occlusal carious deciduous molar teeth from children with the ages between 5 to 10 years old were selected. Selection was ma de according to visual inspection, X-ray periapical image and measures of the DIAGNOdent. For treatment the teeth were divided in two groups, 10 to be treated by the Er:YAG laser and 10 with conventional burr. For enamel, the laser energy used was in the interval from 200 to 300 mJ; for the dentine the range was from 100 mJ to 200 mJ. In both cases, the laser frequency was in the range from 2 to 4 Hz. The results have shown that the laser treatment was more accepted by the children than the conventional burro Clinical evaluation of the cavity preparation indicates that the Er:YAG laser treatment is recommend. The DIAGNOdent evaluation method was very effective for diagnosis of carious tissue for initial detection. After successful removal of the carious tissue, confirmed by visual inspection, the DIAGNOdent evaluation method was only effective for the treatment with conventional burro For evaluation of the tooth after cavity preparation with the Er:YAG laser, the measurements oscillate covering the full range of the equipment. Therefore, the use of the DIAGNOdent equipment is indicated only for initial caries diagnosis. (author)

  9. Needs-based sewerage prioritization: alternative to conventional cost-benefit analysis.

    Science.gov (United States)

    Rashid, Md M; Hayes, Donald F

    2011-10-01

    This paper presents an empirical approach to select and prioritize sewerage projects within set budgetary limitations. The methodology includes a model which quantifies benefits of a sewerage project as an index or dimensionless number. The index considers need and urgency of sewerage and other project goals. Benefit is defined as the difference in anticipated impact between the current condition (without the project) and the expected condition with the project. Anticipated benefits primarily include reduction in environmental pollution, reduction of human diseases and morbidity, and other tangible and intangible improvement. This approach is a powerful decision tool for sewerage prioritization and an effective alternative to conventional cost-benefit analysis. Unlike conventional analysis, this approach makes no attempt to convert project benefits and other impacts into a monetary measure. This work recognizes that the decision to provide sewerage based solely on net benefits is not practical. Instead, benefit-cost ratios (B/C) are calculated utilizing cost-effectiveness approach. Using these ratios, 16 unserviced areas of Ensenada, Mexico are ranked. The prioritization rankings produced by this method must be further scrutinized and carefully reviewed for logic, accuracy of input data, and practicality of implementation. A similar framework may also be useful for prioritizing other public works projects. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Comparison of conventional, model-based quantitative planar, and quantitative SPECT image processing methods for organ activity estimation using In-111 agents

    International Nuclear Information System (INIS)

    He, Bin; Frey, Eric C

    2006-01-01

    Accurate quantification of organ radionuclide uptake is important for patient-specific dosimetry. The quantitative accuracy from conventional conjugate view methods is limited by overlap of projections from different organs and background activity, and attenuation and scatter. In this work, we propose and validate a quantitative planar (QPlanar) processing method based on maximum likelihood (ML) estimation of organ activities using 3D organ VOIs and a projector that models the image degrading effects. Both a physical phantom experiment and Monte Carlo simulation (MCS) studies were used to evaluate the new method. In these studies, the accuracies and precisions of organ activity estimates for the QPlanar method were compared with those from conventional planar (CPlanar) processing methods with various corrections for scatter, attenuation and organ overlap, and a quantitative SPECT (QSPECT) processing method. Experimental planar and SPECT projections and registered CT data from an RSD Torso phantom were obtained using a GE Millenium VH/Hawkeye system. The MCS data were obtained from the 3D NCAT phantom with organ activity distributions that modelled the uptake of 111 In ibritumomab tiuxetan. The simulations were performed using parameters appropriate for the same system used in the RSD torso phantom experiment. The organ activity estimates obtained from the CPlanar, QPlanar and QSPECT methods from both experiments were compared. From the results of the MCS experiment, even with ideal organ overlap correction and background subtraction, CPlanar methods provided limited quantitative accuracy. The QPlanar method with accurate modelling of the physical factors increased the quantitative accuracy at the cost of requiring estimates of the organ VOIs in 3D. The accuracy of QPlanar approached that of QSPECT, but required much less acquisition and computation time. Similar results were obtained from the physical phantom experiment. We conclude that the QPlanar method, based

  11. Digital hilar tomography. Comparison with conventional technique

    International Nuclear Information System (INIS)

    Schaefer, C.B.; Braunschweig, R.; Teufl, F.; Kaiser, W.; Claussen, C.D.

    1993-01-01

    The aim of the following study was to compare conventional hilar tomography and digital hilar tomography. 20 patients were examined both with conventional and digital hilar tomography using the same tomographic technique and the identical exposure dose. All patients underwent computed tomography of the chest as a golden standard. The digital technique, especially the edge-enhanced image version, showed superior image quality. ROC-analysis by 4 readers found equal diagnostic performance without any statistical difference. Digital hilar tomography shows a superior and constant image quality and lowers the rate of re-exposure. Therefore, digital hilar tomography is the preferable method. (orig.) [de

  12. A multileaf collimator field prescription preparation system for conventional radiotherapy

    International Nuclear Information System (INIS)

    Du, M.N.; Yu, C. X.; Symons, M.; Yan, D.; Taylor, R.; Matter, R.C.; Gustafson, G.; Martinez, A.; Wong, J.W.

    1995-01-01

    Purpose: The purpose of this work is to develop a prescription preparation system for efficient field shaping using a multileaf collimator that can be used in community settings as well as research institutions. The efficiency advantage of the computer-controlled multileaf collimator, over cerrobend blocks, to shape radiation fields has been shown in conformal treatments, which typically require complete volumetric computerized tomographic data for three-dimensional radiation treatment planning--a utility not readily available to the general community. As a result, most patients today are treated with conventional radiation therapy. Therefore, we believe that it is very important to fully use the same efficiency advantage of multileaf collimator as a block replacement in conventional practice. Methods and Material: The multileaf collimator prescription preparation system developed by us acquires prescription images from different sources, including film scanner and radiation treatment planning systems. The multileaf collimator angle and leaf positions are set from the desired field contour defined on the prescription image, by minimizing the area discrepancies. Interactive graphical tools include manual adjustment of collimator angle and leaf positions, and definition of portions of the field edges that require maximal conformation. Data files of the final leaf positions are transferred to the multileaf collimator controller via a dedicated communication link. Results: We have implemented the field prescription preparation system and a network model for integrating the multileaf collimator and other radiotherapy modalities for routine treatments. For routine plan evaluation, isodose contours measured with film in solid water phantom at prescription depth are overlaid on the prescription image. Preliminary study indicates that the efficiency advantage of the MLC over cerrobend blocks in conformal therapy also holds true for conventional treatments. Conclusion: Our

  13. Conventional natural gas resources of the Western Canada Sedimentary Basin

    International Nuclear Information System (INIS)

    Bowers, B.

    1999-01-01

    The use of decline curve analysis to analyse and extrapolate the production performance of oil and gas reservoirs was discussed. This mathematical analytical tool has been a valid method for estimating the conventional crude oil resources of the Western Canada Sedimentary Basin (WCSB). However, it has failed to provide a generally acceptable estimate of the conventional natural gas resources of the WCSB. This paper proposes solutions to this problem and provides an estimate of the conventional natural gas resources of the basin by statistical analysis of the declining finding rates. Although in the past, decline curve analysis did not reflect the declining finding rates of natural gas in the WCSB, the basin is now sufficiently developed that estimates of conventional natural gas resources can be made by this analytical tool. However, the analysis must take into account the acceleration of natural gas development drilling that has occurred over the lifetime of the basin. It was concluded that ultimate resources of conventional marketable natural gas of the WCSB estimated by decline analysis amount to 230 tcf. It was suggested that further research be done to explain why the Canadian Gas Potential Committee (CGPC) estimate for Alberta differs from the decline curve analysis method. 6 refs., 35 figs

  14. Fifth national report of Brazil for the nuclear safety convention

    International Nuclear Information System (INIS)

    2010-01-01

    This Fifth National Report is a new update to include relevant information for the period of 2007/2009. This document represents the national report prepared as a fulfillment of the Brazilian obligations related to the Convention on Nuclear Safety. In chapter 2 some details are given about the existing nuclear installations. Chapter 3 provides details about the legislation and regulations, including the regulatory framework and the regulatory body. Chapter 4 covers general safety considerations as described in articles 10 to 16 of the Convention. Chapter 5 addresses to the safety of the installations during siting, design, construction and operation. Chapter 6 describes planned activities to further enhance nuclear safety. Chapter 7 presents the final remarks related to the degree of compliance with the Convention obligations

  15. Survival of self-etch adhesive Class II composite restorations using ART and conventional cavity preparations in primary molars.

    NARCIS (Netherlands)

    Eden, E.; Topaloglu-Ak, A.; Frencken, J.E.F.M.; Hof, M.A. van 't

    2006-01-01

    PURPOSE: To test the null-hypothesis that there was no difference in the survival percentages of Class II composite restorations in primary teeth produced through either ART or conventional approaches after 2 years. METHODS: 157 children with 325 Class II cavitated dentin lesions were included in a

  16. Laparoscopic splenectomy using conventional instruments

    Directory of Open Access Journals (Sweden)

    Dalvi A

    2005-01-01

    Full Text Available INTRODUCTION : Laparoscopic splenectomy (LS is an accepted procedure for elective splenectomy. Advancement in technology has extended the possibility of LS in massive splenomegaly [Choy et al., J Laparoendosc Adv Surg Tech A 14(4, 197-200 (2004], trauma [Ren et al., Surg Endosc 15(3, 324 (2001; Mostafa et al., Surg Laparosc Endosc Percutan Tech 12(4, 283-286 (2002], and cirrhosis with portal hypertension [Hashizume et al., Hepatogastroenterology 49(45, 847-852 (2002]. In a developing country, these advanced gadgets may not be always available. We performed LS using conventional and reusable instruments in a public teaching the hospital without the use of the advanced technology. The technique of LS and the outcome in these patients is reported. MATERIALS AND METHODS : Patients undergoing LS for various hematological disorders from 1998 to 2004 were included. Electrocoagulation, clips, and intracorporeal knotting were the techniques used for tackling short-gastric vessels and splenic pedicle. Specimen was delivered through a Pfannensteil incision. RESULTS : A total of 26 patients underwent LS. Twenty-two (85% of patients had spleen size more than 500 g (average weight being 942.55 g. Mean operative time was 214 min (45-390 min. The conversion rate was 11.5% ( n = 3. Average duration of stay was 5.65 days (3-30 days. Accessory spleen was detected and successfully removed in two patients. One patient developed subphrenic abscess. There was no mortality. There was no recurrence of hematological disease. CONCLUSION : Laparoscopic splenectomy using conventional equipment and instruments is safe and effective. Advanced technology has a definite advantage but is not a deterrent to the practice of LS.

  17. A comparison of diamond growth rate using in-liquid and conventional plasma chemical vapor deposition methods

    International Nuclear Information System (INIS)

    Takahashi, Yoshiyuki; Toyota, Hiromichi; Nomura, Shinfuku; Mukasa, Shinobu; Inoue, Toru

    2009-01-01

    In order to make high-speed deposition of diamond effective, diamond growth rates for gas-phase microwave plasma chemical vapor deposition and in-liquid microwave plasma chemical vapor deposition are compared. A mixed gas of methane and hydrogen is used as the source gas for the gas-phase deposition, and a methanol solution of ethanol is used as the source liquid for the in-liquid deposition. The experimental system pressure is in the range of 60-150 kPa. While the growth rate of diamond increases as the pressure increases, the amount of input microwave energy per unit volume of diamond is 1 kW h/mm 3 regardless of the method used. Since the in-liquid deposition method provides a superior cooling effect through the evaporation of the liquid itself, a higher electric input power can be applied to the electrodes under higher pressure environments. The growth rate of in-liquid microwave plasma chemical vapor deposition process is found to be greater than conventional gas-phase microwave plasma chemical vapor deposition process under the same pressure conditions.

  18. A comparison of diamond growth rate using in-liquid and conventional plasma chemical vapor deposition methods

    Science.gov (United States)

    Takahashi, Yoshiyuki; Toyota, Hiromichi; Nomura, Shinfuku; Mukasa, Shinobu; Inoue, Toru

    2009-06-01

    In order to make high-speed deposition of diamond effective, diamond growth rates for gas-phase microwave plasma chemical vapor deposition and in-liquid microwave plasma chemical vapor deposition are compared. A mixed gas of methane and hydrogen is used as the source gas for the gas-phase deposition, and a methanol solution of ethanol is used as the source liquid for the in-liquid deposition. The experimental system pressure is in the range of 60-150 kPa. While the growth rate of diamond increases as the pressure increases, the amount of input microwave energy per unit volume of diamond is 1 kW h/mm3 regardless of the method used. Since the in-liquid deposition method provides a superior cooling effect through the evaporation of the liquid itself, a higher electric input power can be applied to the electrodes under higher pressure environments. The growth rate of in-liquid microwave plasma chemical vapor deposition process is found to be greater than conventional gas-phase microwave plasma chemical vapor deposition process under the same pressure conditions.

  19. Microstructural and Mechanical Properties of Porous 60NiTi Prepared by Conventional Press-and-sinter Method

    Directory of Open Access Journals (Sweden)

    Khanlari Khashayar

    2017-01-01

    Full Text Available An intermetallic nickel-titanium alloy, 60NiTi, comprised of approximately 60 wt.% Ni and 40 wt.% Ti, contains a broad combination of physical and mechanical properties such as high hardness, low elastic modulus, resistance to aqueous corrosion and good biocompatibility. These unique combinations make this alloy an attractive candidate for medical components such as implants and prosthesis, where biocompatible materials with high hardness and low stiffness are typically used. The conventional press-and-sinter method which represents the least complex, most flexible and economic powder metallurgy method was used to produce porous 60NiTi parts suitable for biomedical applications. The effect of sintering holding time on the microstructure and mechanical properties is investigated. The structure of the as sintered parts is quite porous which is beneficial based on the medical point of view. The ultimate compressive strength of the samples is higher than that of the compact human bone and can, therefore, meet the strength demand of implants for general bone replacement applications.

  20. Probiotic or Conventional Yogurt for Treating Antibiotic-associated Diarrhea: A Clinical Trial Study

    Directory of Open Access Journals (Sweden)

    Majid Khademian

    2018-03-01

    Full Text Available Background The popularity of probiotics is on the rise. Despite the beneficial effects of antibiotics, gastrointestinal health is at risk of diarrhea. This study aimed to investigate whether probiotic yogurt is of capability to prevent the incidence of diarrhea versus conventional yogurt. Materials and Methods This controlled, randomized, double-blind trial was designed to recruit 48 hospitalized children, whose treatments included different types of antibiotics. They were subsequently assigned into a 1:1 ratio into groups A and B at random. The first group was instructed to consume probiotic yogurt (Bifidobacterium strains and Lactobacillus acidophilus, while the second were on conventional yogurt (placebo containing Streptococcus thermophiles and Lactobacillus bulgaricus at least for 7 days. The incidence of diarrhea, its onset and duration were compared between the two groups. Results The findings indicated that there was no statistically significant difference between the experimental and control groups (p > 0.05. No significant decrease was observed in the incidence of diarrhea between the groups following adjustment for negative C-reactive protein (CRP (p > 0.05. Conclusion According to the results, the consumption of yogurt, either probiotic or conventional, reduced the incidence, duration, and onset of antibiotic-associated diarrhea in pediatric population. This study showed no significantly better performance for probiotic yogurt than conventional yogurt.

  1. Chemical Weapons Convention

    National Research Council Canada - National Science Library

    1997-01-01

    On April 29, 1997, the Convention on the Prohibition of the Development, Production, Stockpiling, and Use of Chemical Weapons and on Their Destruction, known as the Chemical Weapons Convention (CWC...

  2. Implementing the chemical weapons convention

    Energy Technology Data Exchange (ETDEWEB)

    Kellman, B.; Tanzman, E. A.

    1999-12-07

    In 1993, as the CWC ratification process was beginning, concerns arose that the complexity of integrating the CWC with national law could cause each nation to implement the Convention without regard to what other nations were doing, thereby causing inconsistencies among States as to how the CWC would be carried out. As a result, the author's colleagues and the author prepared the Manual for National Implementation of the Chemical Weapons Convention and presented it to each national delegation at the December 1993 meeting of the Preparatory Commission in The Hague. During its preparation, the Committee of CWC Legal Experts, a group of distinguished international jurists, law professors, legally-trained diplomats, government officials, and Parliamentarians from every region of the world, including Central Europe, reviewed the Manual. In February 1998, they finished the second edition of the Manual in order to update it in light of developments since the CWC entered into force on 29 April 1997. The Manual tries to increase understanding of the Convention by identifying its obligations and suggesting methods of meeting them. Education about CWC obligations and available alternatives to comply with these requirements can facilitate national response that are consistent among States Parties. Thus, the Manual offers options that can strengthen international realization of the Convention's goals if States Parties act compatibly in implementing them. Equally important, it is intended to build confidence that the legal issues raised by the Convention are finite and addressable. They are now nearing competition of an internet version of this document so that interested persons can access it electronically and can view the full text of all of the national implementing legislation it cites. The internet address, or URL, for the internet version of the Manual is http: //www.cwc.ard.gov. This paper draws from the Manual. It comparatively addresses approximately thirty

  3. Implementing the chemical weapons convention

    International Nuclear Information System (INIS)

    Kellman, B.; Tanzman, E. A.

    1999-01-01

    In 1993, as the CWC ratification process was beginning, concerns arose that the complexity of integrating the CWC with national law could cause each nation to implement the Convention without regard to what other nations were doing, thereby causing inconsistencies among States as to how the CWC would be carried out. As a result, the author's colleagues and the author prepared the Manual for National Implementation of the Chemical Weapons Convention and presented it to each national delegation at the December 1993 meeting of the Preparatory Commission in The Hague. During its preparation, the Committee of CWC Legal Experts, a group of distinguished international jurists, law professors, legally-trained diplomats, government officials, and Parliamentarians from every region of the world, including Central Europe, reviewed the Manual. In February 1998, they finished the second edition of the Manual in order to update it in light of developments since the CWC entered into force on 29 April 1997. The Manual tries to increase understanding of the Convention by identifying its obligations and suggesting methods of meeting them. Education about CWC obligations and available alternatives to comply with these requirements can facilitate national response that are consistent among States Parties. Thus, the Manual offers options that can strengthen international realization of the Convention's goals if States Parties act compatibly in implementing them. Equally important, it is intended to build confidence that the legal issues raised by the Convention are finite and addressable. They are now nearing competition of an internet version of this document so that interested persons can access it electronically and can view the full text of all of the national implementing legislation it cites. The internet address, or URL, for the internet version of the Manual is http: //www.cwc.ard.gov. This paper draws from the Manual. It comparatively addresses approximately thirty

  4. CT and conventional radiographic techniques in interstitial pulmonary disease

    International Nuclear Information System (INIS)

    Leipner, N.; Schueller, H.; Uexkuell-Gueldenband, V. v.; Schlolaut, K.H.; Overlack, A.; Bonn Univ.

    1988-01-01

    One hundred and sixty-four patients with pulmonary fibrosis were examined by CT and by conventional radiological methods. Sixty patients had asbestosis, thirty-nine silicosis, forty sarcoidosis and twenty-five had idiopathic pulmonary fibrosis. CT is superior to conventional radiography in evaluating interstitial pulmonary changes, particularly of the pleura and the lung parenchyma. In sixty-nine patients there were some findings which could only be demonstrated by CT. In asbestosis, silicosis and sarcoidosis the CT classification of the lung parenchyma which we have suggested produces significantly better correlation with vital capacity than can be achieved from conventional chest films, according to the guidelines of the I.L.O. (orig./GDG) [de

  5. National Nuclear Safety Report 2001. Convention on Nuclear Safety

    International Nuclear Information System (INIS)

    2001-01-01

    The First National Nuclear Safety Report was presented at the first review meeting of the Nuclear Safety Convention. At that time it was concluded that Argentina met the obligations of the Convention. This second National Nuclear Safety Report is an updated report which includes all safety aspects of the Argentinian nuclear power plants and the measures taken to enhance the safety of the plants. The present report also takes into account the observations and discussions maintained during the first review meeting. The conclusion made in the first review meeting about the compliance by Argentina of the obligations of the Convention are included as Annex 1. In general, the information contained in this Report has been updated since March 31, 1998 to March 31, 2001. Those aspects that remain unchanged were not addressed in this second report with the objective of avoiding repetitions and in order to carry out a detailed analysis considering article by article. As a result of the above mentioned detailed analysis of all the Articles, it can be stated that the country fulfils all the obligations imposed by the Nuclear Safety Convention

  6. Secondary waste minimization in analytical methods

    International Nuclear Information System (INIS)

    Green, D.W.; Smith, L.L.; Crain, J.S.; Boparai, A.S.; Kiely, J.T.; Yaeger, J.S.; Schilling, J.B.

    1995-01-01

    The characterization phase of site remediation is an important and costly part of the process. Because toxic solvents and other hazardous materials are used in common analytical methods, characterization is also a source of new waste, including mixed waste. Alternative analytical methods can reduce the volume or form of hazardous waste produced either in the sample preparation step or in the measurement step. The authors are examining alternative methods in the areas of inorganic, radiological, and organic analysis. For determining inorganic constituents, alternative methods were studied for sample introduction into inductively coupled plasma spectrometers. Figures of merit for the alternative methods, as well as their associated waste volumes, were compared with the conventional approaches. In the radiological area, the authors are comparing conventional methods for gross α/β measurements of soil samples to an alternative method that uses high-pressure microwave dissolution. For determination of organic constituents, microwave-assisted extraction was studied for RCRA regulated semivolatile organics in a variety of solid matrices, including spiked samples in blank soil; polynuclear aromatic hydrocarbons in soils, sludges, and sediments; and semivolatile organics in soil. Extraction efficiencies were determined under varying conditions of time, temperature, microwave power, moisture content, and extraction solvent. Solvent usage was cut from the 300 mL used in conventional extraction methods to about 30 mL. Extraction results varied from one matrix to another. In most cases, the microwave-assisted extraction technique was as efficient as the more common Soxhlet or sonication extraction techniques

  7. Systems and Methods for Fabricating Structures Including Metallic Glass-Based Materials Using Low Pressure Casting

    Science.gov (United States)

    Hofmann, Douglas C. (Inventor); Kennett, Andrew (Inventor)

    2018-01-01

    Systems and methods to fabricate objects including metallic glass-based materials using low-pressure casting techniques are described. In one embodiment, a method of fabricating an object that includes a metallic glass-based material includes: introducing molten alloy into a mold cavity defined by a mold using a low enough pressure such that the molten alloy does not conform to features of the mold cavity that are smaller than 100 microns; and cooling the molten alloy such that it solidifies, the solid including a metallic glass-based material.

  8. System Response Analysis and Model Order Reduction, Using Conventional Method, Bond Graph Technique and Genetic Programming

    Directory of Open Access Journals (Sweden)

    Lubna Moin

    2009-04-01

    Full Text Available This research paper basically explores and compares the different modeling and analysis techniques and than it also explores the model order reduction approach and significance. The traditional modeling and simulation techniques for dynamic systems are generally adequate for single-domain systems only, but the Bond Graph technique provides new strategies for reliable solutions of multi-domain system. They are also used for analyzing linear and non linear dynamic production system, artificial intelligence, image processing, robotics and industrial automation. This paper describes a unique technique of generating the Genetic design from the tree structured transfer function obtained from Bond Graph. This research work combines bond graphs for model representation with Genetic programming for exploring different ideas on design space tree structured transfer function result from replacing typical bond graph element with their impedance equivalent specifying impedance lows for Bond Graph multiport. This tree structured form thus obtained from Bond Graph is applied for generating the Genetic Tree. Application studies will identify key issues and importance for advancing this approach towards becoming on effective and efficient design tool for synthesizing design for Electrical system. In the first phase, the system is modeled using Bond Graph technique. Its system response and transfer function with conventional and Bond Graph method is analyzed and then a approach towards model order reduction is observed. The suggested algorithm and other known modern model order reduction techniques are applied to a 11th order high pass filter [1], with different approach. The model order reduction technique developed in this paper has least reduction errors and secondly the final model retains structural information. The system response and the stability analysis of the system transfer function taken by conventional and by Bond Graph method is compared and

  9. Uncertainties in the dosimetric assessments of NORM management in conventional waste repository

    International Nuclear Information System (INIS)

    Mora, J. C.; Robles, B.

    2012-01-01

    Naturally Occurring Radioactive Materials (NORM) are generated in huge quantities in several industries-NORM industries-and their management has been formerly carried out in most countries under considerations of industrial non radioactive wastes, with varying considerations on their radioactive content. As the concentration of non radioactive tonics in several of those materials is relatively high, they were treated as toxic materials. This implies that the materials must be previously conditioned using conventional methods and that the waste disposal itself must be prepared to isolate the toxic from the environment for long periods of time. Spanish regulation for these conventional toxic waste disposals include conditions that assure adequate isolation, also including considerations on their radioactive content in such a way that their management way guarantee radiological protection on the people and the environment. After the 96/29 European Directive (the European BSS), radiological implications on NORM industries and their residual materials must be considered. One option that can be considered for the disposal of NORM with activity concentrations above the established unconditional clearance level is the use of the same industrial waste disposals, if guarantees for corresponding radiological criteria are accomplished, according to Authorities establishment. This work analyses the radiological implications of the management of NORM under the considerations applicable for their management as conventional waste, emphasising in activity concentrations slightly over unconditional clearance levels specifically from 1 Bq up to 50 Bq.g - 1. Resulting generic dose assessments are usually carried out under highly conservative hypothesis. This study discusses uncertainties that should be considered to include possible variation due to climate factors or other parameters used in the assessment models. (Author)13 refs.

  10. Solar cells, structures including organometallic halide perovskite monocrystalline films, and methods of preparation thereof

    KAUST Repository

    Bakr, Osman; Peng, Wei; Wang, Lingfei

    2017-01-01

    Embodiments of the present disclosure provide for solar cells including an organometallic halide perovskite monocrystalline film (see fig. 1.1B), other devices including the organometallic halide perovskite monocrystalline film, methods of making

  11. The Hague Judgments Convention

    DEFF Research Database (Denmark)

    Nielsen, Peter Arnt

    2011-01-01

    The Hague Judgments Convention of 2005 is the first global convention on international jurisdiction and recognition and enforcement of judgments in civil and commercial matters. The author explains the political and legal background of the Convention, its content and certain crucial issues during...

  12. Electrode assemblies, plasma apparatuses and systems including electrode assemblies, and methods for generating plasma

    Science.gov (United States)

    Kong, Peter C; Grandy, Jon D; Detering, Brent A; Zuck, Larry D

    2013-09-17

    Electrode assemblies for plasma reactors include a structure or device for constraining an arc endpoint to a selected area or region on an electrode. In some embodiments, the structure or device may comprise one or more insulating members covering a portion of an electrode. In additional embodiments, the structure or device may provide a magnetic field configured to control a location of an arc endpoint on the electrode. Plasma generating modules, apparatus, and systems include such electrode assemblies. Methods for generating a plasma include covering at least a portion of a surface of an electrode with an electrically insulating member to constrain a location of an arc endpoint on the electrode. Additional methods for generating a plasma include generating a magnetic field to constrain a location of an arc endpoint on an electrode.

  13. POSITIONING ANALYSIS OF ISLAMIC BANK vis-àvis CONVENTIONAL BANK IN INDONESIA USING PARAMETRIC SFA AND DFA METHODS15

    Directory of Open Access Journals (Sweden)

    Ir Ascarya

    2014-03-01

    Full Text Available This study will measure and compare the efficiency of Conventional and Islamic banks in Indonesia using parametric approach stochastic frontier approach (SFA and distribution free approach (DFA. These measurements will provide comprehensive and robust results of efficiency of individual bank compare to its peer group. The results using parametric SFA show that in 2002, conventional banks (0.79 were slightly more efficient than Islamic banks (0.77, while in 2003, the efficiency of Islamic banks improved to 0.84 and the efficiency of conventional banks worsen to 0.76, so that Islamic banks have become more efficient than conventional banks. Conventional and Islamic banks have been improving and converged to the highest level of efficiency (1.00 since 2004. The DFA results show that conventional banks (0.89 are only slightly more efficient than Islamic banks (0.87. Conventional public bank (0.93 is the most efficient, while Islamic regional bank (0.84 is the least efficient. Moreover, efficient banks (conventional and Islamic do not always have lower OCOI (operating costs divided by operating income, while banks with better OCOI usually are more profitable (have better return on assets or ROA. Therefore, technically, Islamic banks have shown their readiness to compete head to head with their conventional counterparts. However, other aspects, such as, number of networks and branches, service quality, convenience, products and services provided, human resources, and pricing, should have become the next priorities for improvements.JEL Classification : C10, C33, G21, G28Keywords : Islamic Banking, Efficiency, Stochastic Frontier Approach, Distribution Free Approach

  14. Ex Vivo Comparison of Mtwo and RaCe Rotary File Systems in Root Canal Deviation: One File Only versus the Conventional Method.

    Science.gov (United States)

    Aminsobhani, Mohsen; Razmi, Hasan; Nozari, Solmaz

    2015-07-01

    Cleaning and shaping of the root canal system is an important step in endodontic therapy. New instruments incorporate new preparation techniques that can improve the efficacy of cleaning and shaping. The aim of this study was to compare the efficacy of Mtwo and RaCe rotary file systems in straightening the canal curvature using only one file or the conventional method. Sixty mesial roots of extracted human mandibular molars were prepared by RaCe and Mtwo nickel-titanium (NiTi) rotary files using the conventional and only one rotary file methods. The working length was 18 mm and the curvatures of the root canals were between 15-45°. By superimposing x-ray images before and after the instrumentation, deviation of the canals was assessed using Adobe Photoshop CS3 software. Preparation time was recorded. Data were analyzed using three-way ANOVA and Tukey's post hoc test. There were no significant differences between RaCe and Mtwo or between the two root canal preparation methods in root canal deviation in buccolingual and mesiodistal radiographs (P>0.05). Changes of root canal curvature in >35° subgroups were significantly more than in other subgroups with smaller canal curvatures. Preparation time was shorter in one file only technique. According to the results, the two rotary systems and the two root canal preparation methods had equal efficacy in straightening the canals; but the preparation time was shorter in one file only group.

  15. An approach to include soil carbon changes in life cycle assessments

    DEFF Research Database (Denmark)

    Petersen, Bjorn Molt; Knudsen, Marie Trydeman; Hermansen, John Erik

    2013-01-01

    to estimate carbon sequestration to be included in LCA is suggested and applied to two examples where the inclusion of carbon sequestration is especially relevant: 1) Bioenergy: removal of straw from a Danish soil for energy purposes and 2) Organic versus conventional farming: comparative study of soybean...... comparable to the IPCC 2006 tier I approach in a time perspective of 20 year, where after the suggested methodology showed a continued soil carbon change toward a new steady state. The suggested method estimated a carbon sequestration for the first example when storing straw in the soil instead of using...... it for bioenergy of 54, 97 and 213 kg C t(-1) straw C in a 200, 100 and 20 years perspective, respectively. For the conversion from conventional to organic soybean production, a difference of 32, 60 or 143 kg soil C ha(-1) yr(-1) in a 200,100 or 20 years perspective, respectively was found. The study indicated...

  16. The Aarhus Convention: A new regional convention on citizens' environmental rights

    International Nuclear Information System (INIS)

    Wates, J.

    2000-01-01

    The UN ECE Convention on Access to Information, Public Participation in Decision-making and Access to Justice in Environmental Matters had been adopted at Arhus, Denmark, at the Fourth Ministerial Conference in the 'Environment for Europe' process, and signed by thirty-five countries and the European Community. This paper summarises the main features of the Convention and briefly discusses its relevance to radioactive waste management issues. It then describes some of the activities currently being undertaken under the auspices of the Convention. (author)

  17. Build green and conventional materials off-gassing tests: A final report

    Energy Technology Data Exchange (ETDEWEB)

    Piersol, P.

    1995-12-31

    Build Green is a certification program that will identify and label building products with a known recycled content. The introduction of these recycled materials has raised the concern that they may emit more indoor pollutants than conventional materials. This study addresses that concern by analyzing Build Green and conventional materials to assess their potential for off-gassing. The study involved emission tests of 37 materials including carpets, carpet undercushions, structural lumber, foundation material, insulation, drywall, fiberboard, counter tops, and cabinetry. The results presented in this report include comparisons of Build Green and conventional materials in terms of emissions of volatile organic compounds and formaldehyde, the material loading ratio, and discussion of the specific sources of the emissions.

  18. Comparison of diagnostic value of conventional ultrasonography and shear wave elastography in the prediction of thyroid lesions malignancy.

    Directory of Open Access Journals (Sweden)

    Ewelina Szczepanek-Parulska

    Full Text Available INTRODUCTION: Thyroid nodular disease (TND is a very common disorder. However, since the rate of malignancy is reported to be 3-10%, only a minority of patients require aggressive surgical treatment. As a result, there is a need for diagnostic tools which would allow for a reliable differentiation between benign and malignant nodules. Although a number of conventional ultrasonographic (US features are proved to be markers of malignancy, Shear Wave Elastography (SWE is considered to be an improvement of conventional US. The aim of this study was to compare conventional US markers and SWE diagnostic values in the differentiation of benign and malignant thyroid nodules. MATERIALS AND METHODS: All patients referred for thyroidectomy, irrespective of the indications, underwent a US thyroid examination prospectively. Patients with TND were included into the study. Results of the US and SWE examinations were compared with post-surgical histopathology. RESULTS: One hundred and twenty two patients with 393 thyroid nodules were included into the study. Twenty two patients were diagnosed with cancer. SWE turned out to be a predictor of malignancy superior to any other conventional US markers (OR=54.5 using qualitative scales and 40.8 using quantitative data on maximal stiffness with a threshold of 50 kPa. CONCLUSIONS: Although most conventional US markers of malignancy prove to be significant, none of them are characterized by both high sensitivity and specificity. SWE seems to be an important step forward, allowing for a more reliable distinction of benign and malignant thyroid nodules. Our study, assessing SWE properties on the highest number of thyroid lesions at the time of publication, confirms the high diagnostic value of this technique. It also indicates that a quantitative evaluation of thyroid lesions is not superior to simpler qualitative methods.

  19. Comparison of E-test with other conventional susceptibility testing methods for ciprofloxacin and gentamicin against gram negative enteric bacilli.

    Science.gov (United States)

    Ogbolu, D O; Terry-Alli, O A; Daini, O A; Olabiyi, F A; Igharo, E A

    2012-06-01

    Increasing antibiotic resistance in Gram negative bacteria has led to the need for a faster and reliable method for determining antimicrobial susceptibility testing. In a resource poor setting like ours, it's also important to look for methods that will be clinically and economically beneficial to the patient. This study was aimed at evaluating the Epsilometer test (E-test) and conventional methods for determining antimicrobial susceptibility of isolates of Gram-negative enteric bacteria to ciprofloxacin and gentamicin. Disc diffusion, E-test, broth dilution and agar dilution methods were performed on 54 bacterial isolates. Using the E-test, 88.9% of bacterial isolates were resistant to ciprofloxacin, 92.6% were resistant using broth microdilution, 96.3% were resistant using agar dilution and 72.2% were resistant using disc diffusion. Minimum inhibitory concentration (MIC50) of isolates for gentamicin showed significant difference for all the techniques (p 0.05). Both E-test and broth dilution methods showed high levels of agreement (p > 0.05), there were low levels of agreement between E-test and agar dilution method (p < 0.05), especially at MIC50. The E-test can therefore be considered a reliable method to determine antimicrobial susceptibility testing and it gives results which are at least as accurate as those obtained by the broth dilution method.

  20. Convention on nuclear safety. Rules of procedure and financial rules

    International Nuclear Information System (INIS)

    1998-01-01

    The document presents the Rules of Procedure and Financial Rules that apply mutatis mutandis to any meeting of the Contracting Parties to the Convention on Nuclear Safety (INFCIRC/449) convened in accordance with Chapter 3 of the Convention. It includes four parts: General provisions, Preparatory process for review meetings, Review meetings, and Amendment and interpretation of rules

  1. Conventional diagnostic imaging of the temporal bone. A historical review

    International Nuclear Information System (INIS)

    Canigiani, G.

    1997-01-01

    The Viennese Medical School played an important role in the development of radiological examinations and signs of the temporal bone with conventional X-rays. Famous pioneers include E.G. Mayer (1893-1969) and L. Psenner (1910-1986). Nowadays conventional X-rays and tomography have lost their important role in diagnostic radiology of the temporal bone, but the basic principles established in those early years of radiology are still used now. This statement is correct not only for conventional X-rays, but particularly for 'poly'-tomography in comparison with CT. (orig.) [de

  2. International Convention for the Suppression of Acts of Nuclear Terrorism. United Nations 2005: International Convention for the Suppression of Acts of Nuclear Terrorism

    International Nuclear Information System (INIS)

    Anon.

    2005-01-01

    The International Convention for the Suppression of Acts of Nuclear Terrorism is a 2005 United Nations treaty designed to criminalize acts of nuclear terrorism and to promote police and judicial cooperation to prevent, investigate and punish those acts. As of September 2016, the convention has 115 signatories and 106 state parties, including the nuclear powers China, France, India, Russia, the United Kingdom, and the United States. The Convention covers a broad range of acts and possible targets, including nuclear power plants and nuclear reactors; covers threats and attempts to commit such crimes or to participate in them, as an accomplice; stipulates that offenders shall be either extradited or prosecuted; encourages States to cooperate in preventing terrorist attacks by sharing information and assisting each other in connection with criminal investigations and extradition proceedings; and, deals with both crisis situations, assisting States to solve the situations and post-crisis situations by rendering nuclear material safe through the International Atomic Energy Agency (IAEA)

  3. microRNA biosensors: Opportunities and challenges among conventional and commercially available techniques.

    Science.gov (United States)

    Kilic, Tugba; Erdem, Arzum; Ozsoz, Mehmet; Carrara, Sandro

    2018-01-15

    As being the most extensively studied, non-coding, evolutionary conserved, post-transcriptional gene regulators of genome, microRNAs (miRNAs) have taken great attention among various disciplines due to their important roles in biological processes and link with cancer. Due to their diagnostic value, there have been many conventional methods used in detection of miRNAs including northern blotting, quantitative real time PCR (qRT-PCR) and microarray technology besides novel techniques based on various nanotechnology approaches and molecular biology tools including miRNA biosensors. The aim of this review is to explain the importance of miRNAs in biomedical field with an emphasis on early cancer diagnosis by overviewing both research based and commercially available miRNA detection methods in the last decade considering their strengths and weakness with an emphasis on miRNA biosensors. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. On-line high-performance liquid chromatography-ultraviolet-nuclear magnetic resonance method of the markers of nerve agents for verification of the Chemical Weapons Convention.

    Science.gov (United States)

    Mazumder, Avik; Gupta, Hemendra K; Garg, Prabhat; Jain, Rajeev; Dubey, Devendra K

    2009-07-03

    This paper details an on-flow liquid chromatography-ultraviolet-nuclear magnetic resonance (LC-UV-NMR) method for the retrospective detection and identification of alkyl alkylphosphonic acids (AAPAs) and alkylphosphonic acids (APAs), the markers of the toxic nerve agents for verification of the Chemical Weapons Convention (CWC). Initially, the LC-UV-NMR parameters were optimized for benzyl derivatives of the APAs and AAPAs. The optimized parameters include stationary phase C(18), mobile phase methanol:water 78:22 (v/v), UV detection at 268nm and (1)H NMR acquisition conditions. The protocol described herein allowed the detection of analytes through acquisition of high quality NMR spectra from the aqueous solution of the APAs and AAPAs with high concentrations of interfering background chemicals which have been removed by preceding sample preparation. The reported standard deviation for the quantification is related to the UV detector which showed relative standard deviations (RSDs) for quantification within +/-1.1%, while lower limit of detection upto 16mug (in mug absolute) for the NMR detector. Finally the developed LC-UV-NMR method was applied to identify the APAs and AAPAs in real water samples, consequent to solid phase extraction and derivatization. The method is fast (total experiment time approximately 2h), sensitive, rugged and efficient.

  5. Lateral sesamoid position in hallux valgus: correlation with the conventional radiological assessment.

    Science.gov (United States)

    Agrawal, Yuvraj; Desai, Aravind; Mehta, Jaysheel

    2011-12-01

    We aimed to quantify the severity of the hallux valgus based on the lateral sesamoid position and to establish a correlation of our simple assessment method with the conventional radiological assessments. We reviewed one hundred and twenty two dorso-plantar weight bearing radiographs of feet. The intermetatarsal and hallux valgus angles were measured by the conventional methods; and the position of lateral sesamoid in relation to first metatarsal neck was assessed by our new and simple method. Significant correlation was noted between intermetatarsal angle and lateral sesamoid position (Rho 0.74, p lateral sesamoid position and hallux valgus angle (Rho 0.56, p lateral sesamoid position is simple, less time consuming and has statistically significant correlation with that of the established conventional radiological measurements. Copyright © 2011 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  6. Measures to implement the Chemical Weapons Convention

    International Nuclear Information System (INIS)

    Tanzman, E.; Kellman, B.

    1999-01-01

    This seminar is another excellent opportunity for those involved in preventing chemical weapons production and use to learn from each other about how the Chemical Weapons Convention (CWC) can become a foundation of arms control in Africa and around the world. The author is grateful to the staff of the Organization for the Prohibition of Chemical Weapons (OPCW) for inviting him to address this distinguished seminar. The views expressed in this paper are those of the authors alone, and do not represent the position of the government of the US nor or of any other institution. In 1993, as the process of CWC ratification was beginning, concerns arose that the complexity of integrating the treaty with national law would cause each nation to implement the Convention without regard to what other nations were doing, thereby causing inconsistencies among States Parties in how the Convention would be carried out. As a result the Manual for National Implementation of the Chemical Weapons Convention was prepared and presented it to each national delegation at the December 1993 meeting of the Preparatory Commission in The Hague. During its preparation, the Manual was reviewed by the Committee of Legal Experts on National Implementation of the Chemical Weapons Convention, a group of distinguished international jurists, law professors, legally-trained diplomats, government officials, and Parliamentarians from every region of the world, including Mica. In February 1998, the second edition of the Manual was published in order to update it in light of developments since the CWC entered into force on 29 April 1997. The second edition 1998 clarified the national implementation options to reflect post-entry-into-force thinking, added extensive references to national implementing measures that had been enacted by various States Parties, and included a prototype national implementing statute developed by the authors to provide a starting point for those whose national implementing

  7. Measures to implement the Chemical Weapons Convention

    Energy Technology Data Exchange (ETDEWEB)

    Tanzman, E.; Kellman, B.

    1999-11-05

    This seminar is another excellent opportunity for those involved in preventing chemical weapons production and use to learn from each other about how the Chemical Weapons Convention (CWC) can become a foundation of arms control in Africa and around the world. The author is grateful to the staff of the Organization for the Prohibition of Chemical Weapons (OPCW) for inviting him to address this distinguished seminar. The views expressed in this paper are those of the authors alone, and do not represent the position of the government of the US nor or of any other institution. In 1993, as the process of CWC ratification was beginning, concerns arose that the complexity of integrating the treaty with national law would cause each nation to implement the Convention without regard to what other nations were doing, thereby causing inconsistencies among States Parties in how the Convention would be carried out. As a result the Manual for National Implementation of the Chemical Weapons Convention was prepared and presented it to each national delegation at the December 1993 meeting of the Preparatory Commission in The Hague. During its preparation, the Manual was reviewed by the Committee of Legal Experts on National Implementation of the Chemical Weapons Convention, a group of distinguished international jurists, law professors, legally-trained diplomats, government officials, and Parliamentarians from every region of the world, including Mica. In February 1998, the second edition of the Manual was published in order to update it in light of developments since the CWC entered into force on 29 April 1997. The second edition 1998 clarified the national implementation options to reflect post-entry-into-force thinking, added extensive references to national implementing measures that had been enacted by various States Parties, and included a prototype national implementing statute developed by the authors to provide a starting point for those whose national implementing

  8. Contrast-Enhanced Spectral Mammography: Comparison with Conventional Mammography and Histopathology in 152 Women

    OpenAIRE

    Luczyńska, Elzbieta; Heinze-Paluchowska, Sylwia; Dyczek, Sonia; Blecharz, Pawel; Rys, Janusz; Reinfuss, Marian

    2014-01-01

    Objective The goal of the study was to compare conventional mammography (MG) and contrast-enhanced spectral mammography (CESM) in preoperative women. Materials and Methods The study was approved by the local Ethics Committee and all participants provided informed consent. The study included 152 consecutive patients with 173 breast lesions diagnosed on MG or CESM. All MG examinations and consults were conducted in one oncology centre. Non-ionic contrast agent, at a total dose of 1.5 mL/kg body...

  9. Solar cells, structures including organometallic halide perovskite monocrystalline films, and methods of preparation thereof

    KAUST Repository

    Bakr, Osman M.

    2017-03-02

    Embodiments of the present disclosure provide for solar cells including an organometallic halide perovskite monocrystalline film (see fig. 1.1B), other devices including the organometallic halide perovskite monocrystalline film, methods of making organometallic halide perovskite monocrystalline film, and the like.

  10. Non-conventional solvents in liquid phase microextraction and aqueous biphasic systems.

    Science.gov (United States)

    An, Jiwoo; Trujillo-Rodríguez, María J; Pino, Verónica; Anderson, Jared L

    2017-06-02

    The development of rapid, convenient, and high throughput sample preparation approaches such as liquid phase microextraction techniques have been continuously developed over the last decade. More recently, significant attention has been given to the replacement of conventional organic solvents used in liquid phase microextraction techniques in order to reduce toxic waste and to improve selectivity and/or extraction efficiency. With these objectives, non-conventional solvents have been explored in liquid phase microextraction and aqueous biphasic systems. The utilized non-conventional solvents include ionic liquids, magnetic ionic liquids, and deep eutectic solvents. They have been widely used as extraction solvents or additives in various liquid phase microextraction modes including dispersive liquid-liquid microextraction, single-drop microextraction, hollow fiber-liquid phase microextraction, as well as in aqueous biphasic systems. This review provides an overview into the use of non-conventional solvents in these microextraction techniques in the past 5 years (2012-2016). Analytical applications of the techniques are also discussed. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method

    Energy Technology Data Exchange (ETDEWEB)

    You, Sung Hye; Son, Gyu Ri; Lee, Nam Joon [Dept. of Radiology, Korea University Anam Hospital, Seoul (Korea, Republic of); Suh, Sangil; Ryoo, In Seon; Seol, Hae Young [Dept. of Radiology, Korea University Guro Hospital, Seoul (Korea, Republic of); Lee, Young Hen; Seo, Hyung Suk [Dept. of Radiology, Korea University Ansan Hospital, Ansan (Korea, Republic of)

    2017-01-15

    The purpose of this study was to investigate the accuracy and reliability of the semi-automated ultrasonographic volume measurement tool, virtual organ computer-aided analysis (VOCAL), for measuring the volume of parathyroid glands. Volume measurements for 40 parathyroid glands were performed in patients with secondary hyperparathyroidism caused by chronic renal failure. The volume of the parathyroid glands was measured twice by experienced radiologists by two-dimensional (2D) and three-dimensional (3D) methods using conventional sonograms and the VOCAL with 30°angle increments before parathyroidectomy. The specimen volume was also measured postoperatively. Intraclass correlation coefficients (ICCs) and the absolute percentage error were used for estimating the reproducibility and accuracy of the two different methods. The ICC value between two measurements of the 2D method and the 3D method was 0.956 and 0.999, respectively. The mean absolute percentage error of the 2D method and the 3D VOCAL technique was 29.56% and 5.78%, respectively. For accuracy and reliability, the plots of the 3D method showed a more compact distribution than those of the 2D method on the Bland-Altman graph. The rotational VOCAL method for measuring the parathyroid gland is more accurate and reliable than the conventional 2D measurement. This VOCAL method could be used as a more reliable follow-up imaging modality in a patient with hyperparathyroidism.

  12. Assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method

    International Nuclear Information System (INIS)

    You, Sung Hye; Son, Gyu Ri; Lee, Nam Joon; Suh, Sangil; Ryoo, In Seon; Seol, Hae Young; Lee, Young Hen; Seo, Hyung Suk

    2017-01-01

    The purpose of this study was to investigate the accuracy and reliability of the semi-automated ultrasonographic volume measurement tool, virtual organ computer-aided analysis (VOCAL), for measuring the volume of parathyroid glands. Volume measurements for 40 parathyroid glands were performed in patients with secondary hyperparathyroidism caused by chronic renal failure. The volume of the parathyroid glands was measured twice by experienced radiologists by two-dimensional (2D) and three-dimensional (3D) methods using conventional sonograms and the VOCAL with 30°angle increments before parathyroidectomy. The specimen volume was also measured postoperatively. Intraclass correlation coefficients (ICCs) and the absolute percentage error were used for estimating the reproducibility and accuracy of the two different methods. The ICC value between two measurements of the 2D method and the 3D method was 0.956 and 0.999, respectively. The mean absolute percentage error of the 2D method and the 3D VOCAL technique was 29.56% and 5.78%, respectively. For accuracy and reliability, the plots of the 3D method showed a more compact distribution than those of the 2D method on the Bland-Altman graph. The rotational VOCAL method for measuring the parathyroid gland is more accurate and reliable than the conventional 2D measurement. This VOCAL method could be used as a more reliable follow-up imaging modality in a patient with hyperparathyroidism

  13. Fracture healing: direct magnification versus conventional radiography

    International Nuclear Information System (INIS)

    Link, T.M.; Kessler, T.; Lange, T.; Overbeck, J.; Fiebich, M.; Peters, P.E.

    1994-01-01

    The aim of the study was to evaluate the potential of magnification radiography in diagnosing fracture healing and assessing its complications. Seventy-three patients with fractures or who had undergone osteotomy were radiographed with both conventional (non-magnified) and magnification (5-fold) techniques. Since 10 patients were radiographed twice and 1 three times, 83 radiographs using each technique were obtained. All radiographs were analysed and the findings correlated with the patients' follow-up studies. The microfocal X-ray unit used for magnification radiography had a focal spot size of 20-130 μm. As an imaging system, digital luminescence radiography was employed with magnification, while normal film-screen systems were used with conventional radiography. Magnification radiography proved superior to conventional radiography in 47% of cases: endosteal and periosteal callus formations were seen earlier and better in 26 cases, and osseous union could be evaluated with greater certainty in 33 cases. In 49% of cases magnification radiography was equal and in 4% inferior to conventional radiography. Additionally an ''inter-observer analysis'' was carried out. Anatomical and pathological structures were classified into one of four grades. Results were significantly (P < 0.01) better using magnification radiography. We conclude that the magnification technique is a good method for monitoring fracture healing in its early stages. (orig.)

  14. Kinetics study of hydrochlorothiazide lactose liquid state interaction using conventional isothermal arrhenius method under basic and neutral conditions

    Directory of Open Access Journals (Sweden)

    Faranak Ghaderi

    Full Text Available ABSTRACT The Maillard reaction of hydrochlorothiazide (HCTZ and lactose has been previously demonstrated in pharmaceutical formulations. In this study, the activation energy of - hydrohlorothiazide and lactose interaction in the liquid state was ascertained under basic and neutral conditions. Conventional isothermal High Performance Liquid Chromatography (HPLC technique was employed to ascertain the kinetic parameters using Arrhenius method. Results: The activation energy obtained was 82.43 and 100.28 kJ/mol under basic and neutral conditions, respectively. Consequently, it can be inferred that Maillard reaction is significantly affected by pH, which can be used as a control factor whenever the reaction potentially occurs.

  15. Young children's inclusion decisions in moral and social-conventional group norm contexts.

    Science.gov (United States)

    Rizzo, Michael T; Cooley, Shelby; Elenbaas, Laura; Killen, Melanie

    2018-01-01

    Being a member of a peer group involves making decisions about whom to include in or exclude from the group. Sometimes these decisions are related to whether members of the group support or challenge the norms of the group. To examine how young children weigh concerns for group norms and group membership in both moral and social-conventional norm contexts, children (3- to 6-year-olds; N=73) were asked to decide between including an ingroup member who challenged the group's norm or an outgroup member who supported the norm. Groups held either moral (equal or unequal resource allocation) or social-conventional (traditional or nontraditional) norms. In the moral contexts, children were more likely to include the peer who advocated for the moral concern for equality regardless of the peer's group membership or their group's specific norm. In the social-conventional contexts, however, children were more likely to include the peer who advocated for the conventional concern for maintaining traditions but only at the group-specific level. Furthermore, with age children increasingly based their inclusion decisions on normative concerns, rather than on group membership concerns, and differed in their inclusion decisions for ingroups and outgroups. Finally, children reasoned about their decisions by referencing concerns for fairness, group norms, and group membership, suggesting that preschool children weigh multiple concerns when deciding whom to include in their groups. Overall, the current study revealed differences in how preschool children weigh moral and social-conventional concerns in intergroup contexts. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Comparison of Radiofrequency and Electrocautery With Conventional Scalpel Incisions.

    Science.gov (United States)

    Hasar, Zafer Burak; Ozmeric, Nurdan; Ozdemir, Burcu; Gökmenoğlu, Ceren; Baris, Emre; Altan, Gökçen; Kahraman, Sevil

    2016-11-01

    The disadvantages of conventional scalpels, including insufficient control of bleeding, prompted us to search for new alternative methods such as electrosurgery and radiosurgery. In this study, the conventional scalpel was compared with radiosurgery and electrosurgery for wound healing with assessment of lateral heat production, inflammation, and instrument performance. Incisions were made in the palatal mucosa of 42 Wistar rats using a scalpel, electrocautery instrument, or radiofrequency instrument. Postoperative hemostasis, tissue coagulation, and tissue sticking were measured, and pain evaluation through weight loss was recorded. Gingival biopsy specimens from the surgical area were obtained at the time of surgery and 2, 4, 7, and 14 days postoperatively and were evaluated immunohistochemically for inducible nitric oxide synthase and heat shock protein 70. Kruskal-Wallis, 1-way analysis of variance, and Mann-Whitney U tests were used for statistical evaluation. The rats in the electrosurgery and radiosurgery groups had aggressively greater weight loss when compared with the scalpel group in the first 7 days. Hemostasis was better in the electrocautery group, tissue coagulation was greater in the radiofrequency group (P < .001), and tissue sticking was lesser in the scalpel group (P < .001) compared with the other groups. Inducible nitric oxide synthase expression and heat shock protein 70 expression were similar in all 3 groups. Electrosurgery performed better regarding hemostasis, whereas a scalpel was superior in terms of tissue sticking and tissue coagulation. Radiosurgery was superior regarding hemostasis when compared with a conventional scalpel, but it was not as successful as electrosurgery. Copyright © 2016. Published by Elsevier Inc.

  17. Comparison between mechanical freezer and conventional freezing using liquid nitrogen in normozoospermia.

    Science.gov (United States)

    Rahana, A R; Ng, S P; Leong, C F; Rahimah, M D

    2011-10-01

    This study evaluated the effect of human semen cryopreservation using an ultra-low temperature technique with a mechanical freezer at -85°C as an alternative method to the conventional liquid nitrogen technique at -196°C. This was a prospective experimental study conducted in the Medically Assisted Conception unit, Department of Obstetrics and Gynaecology, National University Hospital, Malaysia from January 1, 2006 to April 30, 2007. All normozoospermic semen samples were included in the study. The concentration, motility and percentage of intact DNA of each semen sample were assessed before and after freezing and thawing on Days 7 and 30 post freezing. Sperm cryopreservation at -85°C was comparable to the conventional liquid nitrogen technique for a period of up to 30 days in a normozoospermic sample. There was no statistical difference in concentration (Day 7 p-value is 0.1, Day 30 p-value is 0.2), motility (Day 7 p-value is 0.9, Day 30 p-value is 0.5) and proportion of intact DNA (Day 7 p-value is 0.1, Day 30 p-value is 0.2) between the ultra-low temperature technique and conventional liquid nitrogen cryopreservation at Days 7 and 30 post thawing. This study clearly demonstrates that short-term storage of sperm at -85°C could be a viable alternative to conventional liquid nitrogen cryopreservation at -196°C due to their comparable post-thaw results.

  18. Impact of replacement of conventional Recloser with PulseCloser

    OpenAIRE

    Olgert Metko; Rajmonda Bualoti; Engjell Zeqo

    2011-01-01

    Conventional recloser stresses the circuit with current fault every time they reclose into a fault. After clearing a fault, a conventional recloser simply recloses the interrupters to continuously test the presence of the fault. If the fault is still there, the interrupters are tripped again. Then, after a time delay, the interrupters are reclosed. During reclosing operation of Automatic Recloser, including the faster recloser one, powerful transient processes occurs and significant amount of...

  19. Image quality in conventional film screen system, digital phosphor storage plate mammography in magnification technique and digital mammography in CCD-technique

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Aichinger, U.; Boehner, C.; Dobritz, M.; Bautz, W.; Saebel, M.

    2000-01-01

    Purpose: Comparison of image quality between conventional film screen system, digital phosphor storage plate mammography in magnification technique and digital mammography in CCD-technique. Materials and Methods: Radiograms of a RMI-mammography phantom were acquired using a conventional film screen system, two digital storage plate systems and two digital systems in CCD-technique. Additionally, the radiograms of one digital phosphor storage plate system were post-processed emphasizing contrast and included in the comparison. Results: The detectability of details was the best with the digital mammography in CCD-technique in comparison with the conventional film screen technique resp. digital phosphor storage plate in magnification technique. Conclusions: Based on these results there is the possibility to replace the conventional film screen system by further studies - this has to be confirmed. (orig.) [de

  20. Magnetic resonance dacryocystography: comparison between conventional surface coils and microscopic coils

    International Nuclear Information System (INIS)

    Abreu Junior, Luiz de; Wolosker, Angela Maria Borri; Borri, Maria Lucia; Galvao Filho, Mario de Melo; Hartmann, Luiz Guilherme de Carvalho; D'Ippolito, Giuseppe; Castro, Claudio Campi de

    2008-01-01

    Objective: Magnetic resonance imaging has been utilized in the evaluation of the lacrimal apparatus with some advantages over conventional dacryocystography. The present study was aimed at acquiring high resolution images utilizing microscopic coils for evaluating typical structures of the lacrimal apparatus as compared with the findings observed with conventional surface coils. Materials and methods: Five asymptomatic volunteers with no history of epiphora were submitted to high-field magnetic resonance imaging with microscopic and conventional surface coils, and STIR sequence after instillation of saline solution. The definition of normal anatomic structures of lacrimal apparatuses was compared utilizing conventional and microscopic surface coils. Based on a consensual scoring system, the mean values for each structure were calculated by two observers. Results: In 90% of cases, higher scores were attributed to images acquired with the microscopic coil. On average, a 1.17 point increase was observed in the scoring of anatomic structures imaged with the microscopic coil. Additionally, a subjective improvement was observed in the signal-to-noise ratio with the microscopic coil. Conclusion: Magnetic resonance dacryocystography with microscopic coils is the appropriate method for evaluating the lacrimal apparatus, providing images with better quality as compared with those acquired with conventional surface coils. (author)

  1. The efficiency of conventional microscopic selection is comparable to the hyaluronic acid binding method in selecting spermatozoa for male infertility patients

    OpenAIRE

    Meng-Ting Huang; Robert Kuo-Kuang Lee; Chung-Hao Lu; Ying-Jie Chen; Sheng-Hsiang Li; Yuh-Ming Hwu

    2015-01-01

    Objective: To evaluate if hyaluronic acid (HA)-bound spermatozoa surpassed conventional microscopy-selected spermatozoa in the status of sperm DNA integrity by acridine orange (AO) fluorescence staining. Materials and methods: Spermatozoa obtained from couples with indication for the intracytoplasmic sperm injection (ICSI) procedure due to male infertility (n = 34) and control males with normal sperm parameters (n = 12) were analyzed using AO fluorescence staining after density-gradient ce...

  2. Evaluation of the effect of salts on chemical, structural, textural, sensory and heating properties of cheese: Contribution of conventional methods and spectral ones.

    Science.gov (United States)

    Loudiyi, M; Aït-Kaddour, A

    2018-03-21

    Chemical composition, sensory characteristics, textural and functional properties are among the most important characteristics, which directly relates to the global quality of cheese and to consumer acceptability. A number of factors including milk composition, processing conditions and salt content, influences these properties. The past decades many investigations were performed on the possibilities to reduce salt content of cheese due to its adverse health effects, the current lifestyle and the awareness of the consumers for nutrition quality products. Due to the multiple potential effects of reducing NaCl (simple reduction or substitution) on cheese attributes, it is of utmost importance to identify and understand those effects in order to control the global quality and safety of the final product. In the present review a collection of the different results and conclusions drawn after studying the effect of salts by conventional (e.g. wet chemistry) and instrumental (e.g. spectral) methods on chemical, structural, textural, sensory and heating properties of cheese are presented.

  3. Conventional RF system design

    International Nuclear Information System (INIS)

    Puglisi, M.

    1994-01-01

    The design of a conventional RF system is always complex and must fit the needs of the particular machine for which it is planned. It follows that many different design criteria should be considered and analyzed, thus exceeding the narrow limits of a lecture. For this reason only the fundamental components of an RF system, including the generators, are considered in this short seminar. The most common formulas are simply presented in the text, while their derivations are shown in the appendices to facilitate, if desired, a more advanced level of understanding. (orig.)

  4. Concurrent Complementary and Alternative Medicine CAM and Conventional Rehabilitation Therapy in the Management of Children with Developmental Disorders

    Directory of Open Access Journals (Sweden)

    Soo Yeon Kim

    2013-01-01

    Full Text Available Background. We investigated the concurrent use of conventional rehabilitations and complementary and alternative medicine (CAM therapies for the long-term management of children with developmental disorders (DDs. Methods. The parents or caregivers of 533 children with DDs (age range, 1–19 years who visited the rehabilitation centers were surveyed using in depth face-to-face interviews. Results. Of the 533 patients enrolled, 520 completed the questionnaire (97% response rate. A total of 292 (56% children were receiving multiple therapies, more than two conventional rehabilitations and CAM, at the time of the interview. A total of 249 (48% children reported lifetime CAM use, 23% used CAM at the time of the interview, and 62% of the patients planned to use CAM therapy in the future. Conventional rehabilitation therapies used at the time of the interview included physical therapy (30%, speech therapy (28%, and occupational therapy (19%, and the CAM therapies included herbal medicine (5% and acupuncture or moxibustion (3%. The respondents indicated that in the future they planned to use acupuncture or moxibustion (57%, occupational therapy (18%, cognitive behavioral therapy (16%, speech therapy (10%, and physical therapy (8%. Conclusion. Concurrent management as conventional rehabilitations and CAM therapies is widely used by children with DDs.

  5. Earthquake analysis of structures including structure-soil interaction by a substructure method

    International Nuclear Information System (INIS)

    Chopra, A.K.; Guttierrez, J.A.

    1977-01-01

    A general substructure method for analysis of response of nuclear power plant structures to earthquake ground motion, including the effects of structure-soil interaction, is summarized. The method is applicable to complex structures idealized as finite element systems and the soil region treated as either a continuum, for example as a viscoelastic halfspace, or idealized as a finite element system. The halfspace idealization permits reliable analysis for sites where essentially similar soils extend to large depths and there is no rigid boundary such as soil-rock interface. For sites where layers of soft soil are underlain by rock at shallow depth, finite element idealization of the soil region is appropriate; in this case, the direct and substructure methods would lead to equivalent results but the latter provides the better alternative. Treating the free field motion directly as the earthquake input in the substructure eliminates the deconvolution calculations and the related assumption-regarding type and direction of earthquake waves-required in the direct method. (Auth.)

  6. Reversing the conventional leather processing sequence for cleaner leather production.

    Science.gov (United States)

    Saravanabhavan, Subramani; Thanikaivelan, Palanisamy; Rao, Jonnalagadda Raghava; Nair, Balachandran Unni; Ramasami, Thirumalachari

    2006-02-01

    Conventional leather processing generally involves a combination of single and multistep processes that employs as well as expels various biological, inorganic, and organic materials. It involves nearly 14-15 steps and discharges a huge amount of pollutants. This is primarily due to the fact that conventional leather processing employs a "do-undo" process logic. In this study, the conventional leather processing steps have been reversed to overcome the problems associated with the conventional method. The charges of the skin matrix and of the chemicals and pH profiles of the process have been judiciously used for reversing the process steps. This reversed process eventually avoids several acidification and basification/neutralization steps used in conventional leather processing. The developed process has been validated through various analyses such as chromium content, shrinkage temperature, softness measurements, scanning electron microscopy, and physical testing of the leathers. Further, the performance of the leathers is shown to be on par with conventionally processed leathers through bulk property evaluation. The process enjoys a significant reduction in COD and TS by 53 and 79%, respectively. Water consumption and discharge is reduced by 65 and 64%, respectively. Also, the process benefits from significant reduction in chemicals, time, power, and cost compared to the conventional process.

  7. Torque expression in self-ligating orthodontic brackets and conventionally ligated brackets: A systematic review

    OpenAIRE

    Al-Thomali, Yousef; Mohamed, Roshan-Noor; Basha, Sakeenabi

    2017-01-01

    Background To evaluate the torque expression of self ligating (SL) orthodontic brackets and conventionally ligated brackets and the torque expression in active and passive SL brackets. Material and Methods Our systematic search included MEDLINE, EMBASE, CINAHL, PsychINFO, Scopus, and key journals and review articles; the date of the last search was April 4th 2016. We graded the methodological quality of the studies by means of the Quality Assessment Tool for Quantitative Studies, developed fo...

  8. An Alternative to Conventional Rock Fragmentation Methods Using SCDA: A Review

    Directory of Open Access Journals (Sweden)

    Radhika Vidanage De Silva

    2016-11-01

    Full Text Available Global energy and material consumption are expected to rise in exponential proportions during the next few decades, generating huge demands for deep earth energy (oil/gas recovery and mineral processing. Under such circumstances, the continuation of existing methods in rock fragmentation in such applications is questionable due to the proven adverse environmental impacts associated with them. In this regard; the possibility of using more environmentally friendly options as Soundless Chemical Demolition Agents (SCDAs play a vital role in replacing harmful conventional rock fragmentation techniques for gas; oil and mineral recovery. This study reviews up to date research on soundless cracking demolition agent (SCDA application on rock fracturing including its limitations and strengths, possible applications in the petroleum industry and the possibility of using existing rock fragmentation models for SCDA-based rock fragmentation; also known as fracking. Though the expansive properties of SCDAs are currently used in some demolition works, the poor usage guidelines available reflect the insufficient research carried out on its material’s behavior. SCDA is a cementitious powdery substance with quicklime (CaO as its primary ingredient that expands upon contact with water; which results in a huge expansive pressure if this CaO hydration reaction occurs in a confined condition. So, the mechanism can be used for rock fragmentation by injecting the SCDA into boreholes of a rock mass; where the resulting expansive pressure is sufficient to create an effective fracture network in the confined rock mass around the borehole. This expansive pressure development, however, dependent on many factors, where formation water content creates a negative influence on this due to required greater degree of hydration under greater water contents and temperature creates a positive influence by accelerating the reaction. Having a precise understanding of the fracture

  9. Deep pelvic endometriosis: Limited additional diagnostic value of postcontrast in comparison with conventional MR images

    International Nuclear Information System (INIS)

    Bazot, Marc; Gasner, Adeline; Lafont, Clarisse; Ballester, Marcos; Daraï, Emile

    2011-01-01

    Objectives: To determine the value of postcontrast MR imaging (MRI) in cases of suspected pelvic endometriosis by assessing interobserver variability of MR imaging according to the endometriotic locations. Methods: This retrospective study included 158 patients with clinical suspicion of endometriosis who had undergone surgery after MRI between January 2004 and April 2009. Three radiologists with different degrees of experience were independently asked to determine the presence of rectosigmoid colon, vaginal, and bladder endometriosis using both conventional and a combination of conventional and postcontrast MRI. Descriptive analysis, ROC analysis and interobserver agreements (kappa values) were calculated. Results: Rectosigmoid colon, vaginal, and bladder endometriosis was present in 65, 39 and eight patients, respectively. The accuracy of conventional assessment for readers 1, 2, and 3 for rectosigmoid colon, vaginal and bladder endometriosis was 77.2%, 74.1% and 96.8%, and 73.4%, 76.6% and 98.7%, and 86.1%, 88.6% and 99.4%, respectively. The accuracy of conventional and postcontrast MR images for readers 1, 2, and 3 for rectosigmoid colon, vaginal and bladder endometriosis was 77.8%, 78.5% and 98.1%, and 83.5%, 83.5% and 99.4%, and 87.3%, 89.2% and 99.4%, respectively. Conclusions: Interobserver variability of MRI using conventional MRI alone is excellent for the diagnosis of DPE. No significant benefit of intravenous gadolinium, rectal or vaginal administration has been demonstrated.

  10. Beyond the conventional: meeting the challenges of landscape governance within the European Landscape Convention?

    Science.gov (United States)

    Scott, Alister

    2011-10-01

    Academics and policy makers seeking to deconstruct landscape face major challenges conceptually, methodologically and institutionally. The meaning(s), identity(ies) and management of landscape are controversial and contested. The European Landscape Convention provides an opportunity for action and change set within new governance agendas addressing interdisciplinarity and spatial planning. This paper critically reviews the complex web of conceptual and methodological frameworks that characterise landscape planning and management and then focuses on emerging landscape governance in Scotland within a mixed method approach involving policy analyses, semi-structured interviews and best practice case studies. Using Dower's (2008) criteria from the Articles of the European Landscape Convention, the results show that whilst some progress has been made in landscape policy and practice, largely through the actions of key individuals and champions, there are significant institutional hurdles and resource limitations to overcome. The need to mainstream positive landscape outcomes requires a significant culture change where a one-size-fits-all approach does not work. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Comparison of Land, Water, and Energy Requirements of Lettuce Grown Using Hydroponic vs. Conventional Agricultural Methods.

    Science.gov (United States)

    Barbosa, Guilherme Lages; Gadelha, Francisca Daiane Almeida; Kublik, Natalya; Proctor, Alan; Reichelm, Lucas; Weissinger, Emily; Wohlleb, Gregory M; Halden, Rolf U

    2015-06-16

    The land, water, and energy requirements of hydroponics were compared to those of conventional agriculture by example of lettuce production in Yuma, Arizona, USA. Data were obtained from crop budgets and governmental agricultural statistics, and contrasted with theoretical data for hydroponic lettuce production derived by using engineering equations populated with literature values. Yields of lettuce per greenhouse unit (815 m2) of 41 ± 6.1 kg/m2/y had water and energy demands of 20 ± 3.8 L/kg/y and 90,000 ± 11,000 kJ/kg/y (±standard deviation), respectively. In comparison, conventional production yielded 3.9 ± 0.21 kg/m2/y of produce, with water and energy demands of 250 ± 25 L/kg/y and 1100 ± 75 kJ/kg/y, respectively. Hydroponics offered 11 ± 1.7 times higher yields but required 82 ± 11 times more energy compared to conventionally produced lettuce. To the authors' knowledge, this is the first quantitative comparison of conventional and hydroponic produce production by example of lettuce grown in the southwestern United States. It identified energy availability as a major factor in assessing the sustainability of hydroponics, and it points to water-scarce settings offering an abundance of renewable energy (e.g., from solar, geothermal, or wind power) as particularly attractive regions for hydroponic agriculture.

  12. Assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method

    Directory of Open Access Journals (Sweden)

    Sung-Hye You

    2017-01-01

    Full Text Available Purpose The purpose of this study was to investigate the accuracy and reliability of the semi-automated ultrasonographic volume measurement tool, virtual organ computer-aided analysis (VOCAL, for measuring the volume of parathyroid glands. Methods Volume measurements for 40 parathyroid glands were performed in patients with secondary hyperparathyroidism caused by chronic renal failure. The volume of the parathyroid glands was measured twice by experienced radiologists by two-dimensional (2D and three-dimensional (3D methods using conventional sonograms and the VOCAL with 30°angle increments before parathyroidectomy. The specimen volume was also measured postoperatively. Intraclass correlation coefficients (ICCs and the absolute percentage error were used for estimating the reproducibility and accuracy of the two different methods. Results The ICC value between two measurements of the 2D method and the 3D method was 0.956 and 0.999, respectively. The mean absolute percentage error of the 2D method and the 3D VOCAL technique was 29.56% and 5.78%, respectively. For accuracy and reliability, the plots of the 3D method showed a more compact distribution than those of the 2D method on the Bland-Altman graph. Conclusion The rotational VOCAL method for measuring the parathyroid gland is more accurate and reliable than the conventional 2D measurement. This VOCAL method could be used as a more reliable follow-up imaging modality in a patient with hyperparathyroidism.

  13. Efficacy evaluation of fluoxetine combined with conventional drug treatment on unstable angina patients complicated with depression

    Institute of Scientific and Technical Information of China (English)

    Chun-Hua Liao

    2015-01-01

    Objective:To study the efficacy of fluoxetine combined with conventional drug treatment on unstable angina patients complicated with depression. Methods:120 cases of unstable angina patients with depression were randomly divided into two groups. The anti-depression group received fluoxetine combined with conventional drug therapy; the conventional group received conventional drug therapy. Then contents of monoamine neurotransmitters and their metabolites, antioxidants and inflammatory mediators of both groups were compared. Results:Serum monoamine neurotransmitters NE, 5-HT and HA levels of the anti-depression group were higher than those of the conventional group and metabolites 5-HIAA and HVA contents were lower than those of the conventional group; serum SOD, CAT, GSH and HSP-70 contents of the anti-depression group were higher than those of the conventional group, and hs-CRP, MMP9, MCP1 and HMGB1 contents were lower than those of the conventional group. Conclusion:Fluoxetine combined with conventional drug therapy can increase the contents of monoamine neurotransmitters and antioxidants, and reduce oxidative stress response and inflammatory response; it is an ideal method for treating unstable angina complicated with depression.

  14. A Framework for Including Family Health Spillovers in Economic Evaluation.

    Science.gov (United States)

    Al-Janabi, Hareth; van Exel, Job; Brouwer, Werner; Coast, Joanna

    2016-02-01

    Health care interventions may affect the health of patients' family networks. It has been suggested that these "health spillovers" should be included in economic evaluation, but there is not a systematic method for doing this. In this article, we develop a framework for including health spillovers in economic evaluation. We focus on extra-welfarist economic evaluations where the objective is to maximize health benefits from a health care budget (the "health care perspective"). Our framework involves adapting the conventional cost-effectiveness decision rule to include 2 multiplier effects to internalize the spillover effects. These multiplier effects express the ratio of total health effects (for patients and their family networks) to patient health effects. One multiplier effect is specified for health benefit generated from providing a new intervention, one for health benefit displaced by funding this intervention. We show that using multiplier effects to internalize health spillovers could change the optimal funding decisions and generate additional health benefits to society. © The Author(s) 2015.

  15. Comparison of porcelain bond strength of different metal frameworks prepared by using conventional and recently introduced fabrication methods.

    Science.gov (United States)

    Kaleli, Necati; Saraç, Duygu

    2017-07-01

    Most studies evaluating dental laser sintering systems have focused on the marginal accuracy of the restorations. However, the bond strength at the metal-ceramic interface is another important factor that affects the survival of restorations, and currently, few studies focus on this aspect. The purpose of this in vitro study was to compare the porcelain bond strength of cobalt-chromium (Co-Cr) metal frameworks prepared by using the conventional lost-wax technique, milling, direct metal laser sintering (DMLS), and laser cusing, a direct process powder-bed system. A total of 96 metal frameworks (n=24 in each group) were prepared by using conventional lost-wax (group C), milling (group M), DMLS (group LS), and direct process powder-bed (group LC) methods according to International Organization for Standardization standard ISO 9693-1. After porcelain application, a 3-point bend test was applied to each specimen by using a universal testing machine. Data were statistically analyzed using 1-way ANOVA and Tukey honest significant difference tests (α=.05). Failure types at the metal-ceramic interfaces were examined using stereomicroscopy. Additionally, 1 specimen from each group was prepared for scanning electron microscopy analysis to evaluate the surface topography of metal frameworks. The mean bond strength was 38.08 ±3.82 MPa for group C, 39.29 ±3.51 MPa for group M, 40.73 ±3.58 MPa for group LS, and 41.24 ±3.75 MPa for group LC. Statistically significant differences were observed among the 4 groups (P=.016). All groups, except for LS, exhibited adhesive and mixed type bond failure. Both of the laser sintering methods were found to be successful in terms of metal-ceramic bond strength. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  16. Effects of microwaves on changes in foodstuffs as compared with conventional heat treatment. Pt. 2

    International Nuclear Information System (INIS)

    Kalb, M.; Dehne, L.; Boegl, W.

    1980-01-01

    It is purpose of this study to contribute to the discussion and to answer the question as to whether changes are caused by microwave-heating of foodstuffs, which differ from those caused by conventional heating. This is achieved by summarizing extensive test materials. In the relevant literature, a great number of tests are listed on the cooking and reheating of foodstuffs by means of micro-waves, as compared to conventional methods. The subject of these tests is the determination of quantitative changes of certain ingredients (vitamins, fatty acids etc.) and sensory characteristics (flavour, colour etc.) due to the different heating methods. In addition to cooking and heating, a more comprehensive use of microwaves in preparation of food is discussed in this study. Works on the thawing, blanching, freeze-drying, and pasteurization are taken into account when comparing the different heating methods. Moreover, this study includes a comaprison as to the formation of volatile aromatic compounds, the thermic decomposition of pesticide residues, and the physiological effect of lipids. It was determined that there is no indication of radiation-specific effects, i. e. athermic effects, of microwaves contained in any of the studies reviewed up to now. (orig./MG) [de

  17. Cost comparison of dry-type and conventional cooling systems for representative nuclear generating plans

    International Nuclear Information System (INIS)

    Rossie, J.P.; Cecil, E.A.; Young, R.O.

    1974-01-01

    Results are presented of studies comparing the use of dry-type cooling towers with conventional cooling methods for representative pressurized-water-reactor nuclear power plants. The studies were based on the hypothetical use of dry-type cooling towers for three nuclear power plants now under construction which were designed and are being built to use conventional cooling methods. One of the plants is located in the northeastern United States, one in the Southeast and one in the West. The report also presents the results of comparisons based on a hypothetical plant at a typical eastern United States site. The three electric utilities which participated in these studies have furnished actual construction cost information for the conventional cooling systems being constructed, and the authors have made construction estimates for economically optimum dry cooling systems which might have been built in place of the conventional cooling systems being constructed. The report compares the physical and operating characteristics of dry-type and conventional cooling systems as well as the relative economics of the different cooling methods. The effect of dry cooling on the bus-bar cost of power has been computed for the three selected plants and for the typical eastern plant

  18. Transformation From a Conventional Clinical Microbiology Laboratory to Full Automation.

    Science.gov (United States)

    Moreno-Camacho, José L; Calva-Espinosa, Diana Y; Leal-Leyva, Yoseli Y; Elizalde-Olivas, Dolores C; Campos-Romero, Abraham; Alcántar-Fernández, Jonathan

    2017-12-22

    To validate the performance, reproducibility, and reliability of BD automated instruments in order to establish a fully automated clinical microbiology laboratory. We used control strains and clinical samples to assess the accuracy, reproducibility, and reliability of the BD Kiestra WCA, the BD Phoenix, and BD Bruker MALDI-Biotyper instruments and compared them to previously established conventional methods. The following processes were evaluated: sample inoculation and spreading, colony counts, sorting of cultures, antibiotic susceptibility test, and microbial identification. The BD Kiestra recovered single colonies in less time than conventional methods (e.g. E. coli, 7h vs 10h, respectively) and agreement between both methodologies was excellent for colony counts (κ=0.824) and sorting cultures (κ=0.821). Antibiotic susceptibility tests performed with BD Phoenix and disk diffusion demonstrated 96.3% agreement with both methods. Finally, we compared microbial identification in BD Phoenix and Bruker MALDI-Biotyper and observed perfect agreement (κ=1) and identification at a species level for control strains. Together these instruments allow us to process clinical urine samples in 36h (effective time). The BD automated technologies have improved performance compared with conventional methods, and are suitable for its implementation in very busy microbiology laboratories. © American Society for Clinical Pathology 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  19. The 1968 Brussels convention and liability for nuclear damage

    International Nuclear Information System (INIS)

    Sands, Ph.; Galizzi, P.

    2000-01-01

    The legal regime governing civil liability for transboundary nuclear damage is expressly addressed by two instruments adopted in the 1960's: the 1960 Paris Convention on Third Party Liability in the Field of Nuclear Energy and the 1963 Vienna Convention on Civil Liability for Nuclear Damage These establish particular rules governing the jurisdiction of national courts and other matters, including channelling of liability to nuclear operators, definitions of nuclear damage, the applicable standard of care, and limitations on liability. Another instrument - the 1968 Brussels Convention on Jurisdiction and the Enforcement of Judgements in Civil and Commercial Matters (hereinafter referred to as 'the Brussels Convention') - which is not often mentioned in the nuclear context will nevertheless also be applicable in certain cases. It is premised upon different rules as to forum and applicable law, and presents an alternate vision of the appropriate arrangements governing civil liability for nuclear damage. In this paper we consider the relative merits and demerits of the Brussels Convention from the perspective of non-nuclear states which might suffer damage as a result of a nuclear accident in another state. We conclude that in the context of the applicability of the Brussels Convention the dedicated nuclear liability conventions present few attractions to non-nuclear states in Europe. We focus in particular on issues relating to jurisdiction and applicable law, and do so by reference to a hypothetical accident in the United Kingdom which has transboundary effects in Ireland. (author)

  20. Conventional myelography - evaluation of risk and benefit

    International Nuclear Information System (INIS)

    Hentschel, F.

    1989-01-01

    While the benefit and methodic risk of conventional myelography (KMG) are known, a radiation risk of 0.04 to 0.9 annual radiation-induced cancers can be estimated for all inhabitants of the GDR, dependent on the investigated region and the technique used. An optimized technique can reduce the radiation burden to 50 or 25%. With comparable values of benefit and radiation risk spinal CT and KMG are not contradictory but complementary investigations. Alternative methods (MRT, US) must not be discussed from the standpoint of radiation burden, but according to their availability and their methodic limitations. (author)

  1. Topical opinion paper - Apparent Discrepancies Between Nuclear and Conventional Seismic Standards

    International Nuclear Information System (INIS)

    Donald, John; Smith, Ian

    2003-01-01

    The differences between nuclear and conventional seismic standards are considered and their potential significance discussed. The approach to the design of nuclear facilities is appropriately both more rigorous and conservative than that required by conventional seismic standards and codes. For nuclear seismic design the requirements can be presented as assessment principles, e.g., NII SAPs or a safety guide e.g. IAEA; Seismic Design and Qualification for Nuclear Power Plants. The adoption of novel methods or designs are required to be supported by appropriate research and development with the ability to cite a precedent within the industry being a powerful endorsement. The method adopted must reliably predict the seismic response of the item to be qualified, including the seismic response of attached or supported Structures, Systems and Components. (SSC's) The traditional method adopted for seismic qualification by analysis has been based on linear elastic analyses. This is justified on the basis that the response is reliably predicted and realistic, provided that the elements remain elastic. In contrast the benefit of ductile behaviour of conventional structures within the design envelope has long been recognised and used as the basis to justify significant reductions in the seismic demand. Provided the acceptance criteria are met, the SAPs do not preclude and the IAEA safety guide specifically permits non linear behaviour within the design envelope for category 1 items. Both the current nuclear practice and the current conventional seismic standards can be classified as 'force based'. The displacement based approach, also referred to as performance based engineering (PBE), has been developed as a powerful tool in the evaluation and seismic retrofit of existing structures. This approach could be equally valid to the design of new structures and can be used to represent elastic or non linear behaviour although the full benefit will only be realised in the latter

  2. Treatment of children with Helicobacter infection and malabsorption syndromes with probiotics: Comparison with conventional methods

    Energy Technology Data Exchange (ETDEWEB)

    Lawson, P F [Clinique des Maladies de l' Appareil Digestif, Cotonou (Benin); Lawson, W [Clinique des Maladies de l' Appareil Digestif, Cotonou (Benin); De Maio, G; Andriulli, A [Ospedale Casa Sollievo della Sofferenza, San Giovanni Rotondo (Italy); Ghoos, Y [Lab. Digestie Absoptie, Leuven (Belgium); Brunser, O [Institute of Nutrition and Food Technology, Santiago (Chile)

    2004-07-01

    There is a large interest about Heliobacter pylori infection in childhood nowadays. The prevalence of infection is very high in developing countries and this is extremely correlated to the living conditions with consequences on the future health of children. Contamination mode is not well known but environment factors are involved. We used {sup 13}C Urea Breath Test to assess the prevalence rate in beninese asymptomatic children aged 7-11 years old (about 86%). We evaluated the influence of either conventional or probiotics therapy in eradicating Hp infection and some relationships with growth parameters. We concluded that conventional therapy or use of probiotics might improve infection status and probably influence growth factors in childhood. (author)

  3. Method for automatic localization of MR-visible markers using morphological image processing and conventional pulse sequences: feasibility for image-guided procedures.

    Science.gov (United States)

    Busse, Harald; Trampel, Robert; Gründer, Wilfried; Moche, Michael; Kahn, Thomas

    2007-10-01

    To evaluate the feasibility and accuracy of an automated method to determine the 3D position of MR-visible markers. Inductively coupled RF coils were imaged in a whole-body 1.5T scanner using the body coil and two conventional gradient echo sequences (FLASH and TrueFISP) and large imaging volumes up to (300 mm(3)). To minimize background signals, a flip angle of approximately 1 degrees was used. Morphological 2D image processing in orthogonal scan planes was used to determine the 3D positions of a configuration of three fiducial markers (FMC). The accuracies of the marker positions and of the orientation of the plane defined by the FMC were evaluated at various distances r(M) from the isocenter. Fiducial marker detection with conventional equipment (pulse sequences, imaging coils) was very reliable and highly reproducible over a wide range of experimental conditions. For r(M) method is found to be useful for image-guided procedures. (c) 2007 Wiley-Liss, Inc.

  4. A Critical Analysis of the Conventionally Employed Creep Lifing Methods.

    Science.gov (United States)

    Abdallah, Zakaria; Gray, Veronica; Whittaker, Mark; Perkins, Karen

    2014-04-29

    The deformation of structural alloys presents problems for power plants and aerospace applications due to the demand for elevated temperatures for higher efficiencies and reductions in greenhouse gas emissions. The materials used in such applications experience harsh environments which may lead to deformation and failure of critical components. To avoid such catastrophic failures and also increase efficiency, future designs must utilise novel/improved alloy systems with enhanced temperature capability. In recognising this issue, a detailed understanding of creep is essential for the success of these designs by ensuring components do not experience excessive deformation which may ultimately lead to failure. To achieve this, a variety of parametric methods have been developed to quantify creep and creep fracture in high temperature applications. This study reviews a number of well-known traditionally employed creep lifing methods with some more recent approaches also included. The first section of this paper focuses on predicting the long-term creep rupture properties which is an area of interest for the power generation sector. The second section looks at pre-defined strains and the re-production of full creep curves based on available data which is pertinent to the aerospace industry where components are replaced before failure.

  5. Single-incision laparoscopic surgery and conventional laparoscopic ...

    African Journals Online (AJOL)

    Indications for surgery included grades II-III varicocele or ipsilateral testicular hypotrophy. The SIL-V procedure was performed in 44 patients with roticulating and conventional 5 mm instruments. Testicular vessels were isolated “en bloc,” clipped and cut. Operating time, visual analogue scale and post-operative results were ...

  6. Technologies for the future : conventional recovery enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Isaacs, E. [Alberta Energy Research Inst., Edmonton, AB (Canada)

    2005-07-01

    This conference presentation examined Alberta's oil production and water use; global finding and development costs across continents; and current trends for conventional oil. The presentation examined opportunities for testing new technologies for enhanced oil recovery (EOR) and provided several tables of data on EOR production in the United States. The evolution of United States EOR production, and the number of EOR projects in Canada were also addressed. The presentation also discussed where EOR goes from here as well as the different EOR mechanisms to alter phase behaviour and to alter relative flow. It also discussed chemical methods and major challenges for chemical EOR and examined EOR technologies needing a major push in the Western Canada Sedimentary Basin. Lessons learned from the Joffre site regarding carbon dioxide miscible flood were revealed along with how coal gasification produces substitute natural gas and carbon dioxide for EOR. Suggestions for research and technology and enhanced water management were included. tabs., figs.

  7. Evaluation of various conventional methods for sampling weeds in potato and spinach crops

    Directory of Open Access Journals (Sweden)

    David Jamaica

    2014-04-01

    Full Text Available This study aimed to evaluate (at an exploratory level, some of the different conventional sampling designs in a section of a potato crop and in a commercial crop of spinach. Weeds were sampled in a 16 x 48 m section of a potato crop with a set grid of 192 sections. The cover and density of the weeds were registered in squares of from 0.25 to 64 m². The results were used to create a database that allowed for the simulation of different sampling designs: variables and square size. A second sampling was carried out with these results in a spinach crop of 1.16 ha with a set grid of 6 x 6 m cells, evaluating the cover in 4 m² squares. Another database was created with this information, which was used to simulate other sampling designs such as distribution and quantity of sampling squares. According to the obtained results, a good method for approximating the quantity of squares for diverse samples is 10-12 squares (4 m² for richness per ha and 18 or more squares for abundance per hectare. This square size is optimal since it allows for a sampling of more area without losing sight of low-profile species, with the cover variable best representing the abundance of the weeds.

  8. Discrete event simulation versus conventional system reliability analysis approaches

    DEFF Research Database (Denmark)

    Kozine, Igor

    2010-01-01

    Discrete Event Simulation (DES) environments are rapidly developing and appear to be promising tools for building reliability and risk analysis models of safety-critical systems and human operators. If properly developed, they are an alternative to the conventional human reliability analysis models...... and systems analysis methods such as fault and event trees and Bayesian networks. As one part, the paper describes briefly the author’s experience in applying DES models to the analysis of safety-critical systems in different domains. The other part of the paper is devoted to comparing conventional approaches...

  9. Blood pressure response to conventional and low-dose enalapril in chronic renal failure

    DEFF Research Database (Denmark)

    Elung-Jensen, Thomas; Heisterberg, Jens; Kamper, Anne-Lise

    2003-01-01

    AIMS: In chronic renal failure, the clearance of most ACE inhibitors including enalapril is reduced. Hence, with conventional dosage, plasma enalaprilat may be markedly elevated. It is unclear whether this excess of drug exposure affords an improved control of blood pressure. The aim of the present...... study was to evaluate short-term blood pressure response to two different plasma levels of enalaprilat. METHODS: As part of an open, randomized, controlled trial of the effect of high and low dosage of enalapril on the progression of renal failure, short-term blood pressure response was evaluated. Data...

  10. Comparison of accuracies of an intraoral spectrophotometer and conventional visual method for shade matching using two shade guide systems.

    Science.gov (United States)

    Parameswaran, Vidhya; Anilkumar, S; Lylajam, S; Rajesh, C; Narayan, Vivek

    2016-01-01

    This in vitro study compared the shade matching abilities of an intraoral spectrophotometer and the conventional visual method using two shade guides. The results of previous investigations between color perceived by human observers and color assessed by instruments have been inconclusive. The objectives were to determine accuracies and interrater agreement of both methods and effectiveness of two shade guides with either method. In the visual method, 10 examiners with normal color vision matched target control shade tabs taken from the two shade guides (VITAPAN Classical™ and VITAPAN 3D Master™) with other full sets of the respective shade guides. Each tab was matched 3 times to determine repeatability of visual examiners. The spectrophotometric shade matching was performed by two independent examiners using an intraoral spectrophotometer (VITA Easyshade™) with five repetitions for each tab. Results revealed that visual method had greater accuracy than the spectrophotometer. The spectrophotometer; however, exhibited significantly better interrater agreement as compared to the visual method. While VITAPAN Classical shade guide was more accurate with the spectrophotometer, VITAPAN 3D Master shade guide proved better with visual method. This in vitro study clearly delineates the advantages and limitations of both methods. There were significant differences between the methods with the visual method producing more accurate results than the spectrophotometric method. The spectrophotometer showed far better interrater agreement scores irrespective of the shade guide used. Even though visual shade matching is subjective, it is not inferior and should not be underrated. Judicious combination of both techniques is imperative to attain a successful and esthetic outcome.

  11. Application of the Aarhus Convention

    Directory of Open Access Journals (Sweden)

    Tubić Bojan

    2011-01-01

    Full Text Available Convention on access to information, public participation in decision-making and access to justice in environmental matters (Aarhus Convention has been adopted in 1998 and entered into force three years later. It envisages three elements for strengthening democratic procedures in decision-making: access to information, public participation and access to justice. At the first meeting of the Member States the Aarhus Convention Compliance Committee was founded. The European Union is a party of the Convention and it has implemented the provisions in its legal order. After entering into force of the Convention, several Directives that regulate these issues in the EU have been enacted. Republic of Serbia has ratified the Convention in 2009 and it is currently in the process of its implementation by involving private subjects in decision-making on environmental issues.

  12. ''Augmented reality'' in conventional simulation by projection of 3-D structures into 2-D images. A comparison with virtual methods

    International Nuclear Information System (INIS)

    Deutschmann, H.; Nairz, O.; Zehentmayr, F.; Fastner, G.; Sedlmayer, F.; Steininger, P.; Kopp, P.; Merz, F.; Wurstbauer, K.; Kranzinger, M.; Kametriser, G.; Kopp, M.

    2008-01-01

    Background and purpose: in this study, a new method is introduced, which allows the overlay of three-dimensional structures, that have been delineated on transverse slices, onto the fluoroscopy from conventional simulators in real time. Patients and methods: setup deviations between volumetric imaging and simulation were visualized, measured and corrected for 701 patient isocenters. Results: comparing the accuracy to mere virtual simulation lacking additional X-ray imaging, a clear benefit of the new method could be shown. On average, virtual prostate simulations had to be corrected by 0.48 cm (standard deviation [SD] 0.38), and those of the breast by 0.67 cm (SD 0.66). Conclusion: the presented method provides an easy way to determine entity-specific safety margins related to patient setup errors upon registration of bony anatomy (prostate 0.9 cm for 90% of cases, breast 1.3 cm). The important role of planar X-ray imaging was clearly demonstrated. The innovation can also be applied to adaptive image-guided radiotherapy (IGRT) protocols. (orig.)

  13. Planning, design and technological criteria of conventional and nuclear shelters

    International Nuclear Information System (INIS)

    Sadoon, A.S.

    1989-01-01

    The thesis aims to establish a special criteria for building the shelters in two types. The conventional and nuclear, in respect to planning design and technological aspects, and finally establishing a special reference of planning, design and technology for Iraq which can be used when planning or designing a conventional or nuclear shelter. The thesis included four chapters, the first chapter included definition of shelters, and explanation of the effects of all types of weapons on buildings, and the second chapter included definition of planning and design concepts of shelters in its two types and analytical studies for international examples. The third chapter covered definition for technologies of structural, mechanical, electrical and sanitary systems. The fourth chapter included details of a case study in order to approach the results of research which included the conclusions, recommendations, criteria and prospects of planning design and technological aspects. 51 tabs.; 180 figs.; 32 refs.; 15 apps

  14. Nuclear liability: Joint protocol relating to the application of the Vienna Convention and the Paris Convention, 1988

    International Nuclear Information System (INIS)

    1989-10-01

    The Joint Protocol Relating to the Application of the Vienna Convention and the Paris Convention was adopted by the Conference on the Relationship between the Paris Convention and the Vienna Convention, which met in Vienna, at the Headquarters of the International Atomic Energy Agency on 21 September 1988. The Joint Protocol establishes a link between the Paris Convention on Third Party Liability in the Field of Nuclear Energy of 1960 and the Vienna Convention on Civil Liability for Nuclear Damage of 1963. The Joint Protocol will extend to the States adhering to it the coverage of the two Conventions. It will also resolve potential conflicts of law, which could result from the simultaneous application of the two Conventions to the same nuclear accident. The Conference on the Relationship between the Paris Convention and the Vienna Convention was jointly organized by the International Atomic Energy Agency and the OECD Nuclear Energy Agency. This publication contains the text of the Final Act of the Conference in the six authentic languages, the Joint Protocol Relating to the Application of the Vienna Convention and the Paris Convention, also in the six authentic languages and an explanatory note, prepared by the IAEA and NEA Secretariats, providing background information on the content of the Joint Protocol

  15. Sixth national report of Brazil for the nuclear safety convention

    International Nuclear Information System (INIS)

    2013-01-01

    Brazil has presented periodically its National Report prepared by a group composed of representatives of the various Brazilian organizations with responsibilities related to nuclear safety. Due to the implications of the Fukushima nuclear accident in 2011, an Extraordinary National Report was presented in 2012. This Sixth National Report is an update of the Fifth National Report in relation to the Convention on Nuclear Safety articles and also an update of the Extraordinary Report with respect to the action taken related to lesson learned from the Fukushima accident. It includes relevant information for the period of 2010/2012. This document represents the national report prepared as a fulfillment of the brazilian obligations related to the Convention on Nuclear Safety. In chapter 2 some details are given about the existing nuclear installations. Chapter 3 provides details about the legislation and regulations, including the regulatory framework and the regulatory body. Chapter 4 covers general safety considerations as described in articles 10 to 16 of the Convention. Chapter 5 addresses to the safety of the installations during siting, design, construction and operation. Chapter 6 describes planned activities to further enhance nuclear safety. Chapter 7 presents the final remarks related to the degree of compliance with the Convention obligations

  16. Sixth national report of Brazil for the nuclear safety convention

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-07-01

    Brazil has presented periodically its National Report prepared by a group composed of representatives of the various Brazilian organizations with responsibilities related to nuclear safety. Due to the implications of the Fukushima nuclear accident in 2011, an Extraordinary National Report was presented in 2012. This Sixth National Report is an update of the Fifth National Report in relation to the Convention on Nuclear Safety articles and also an update of the Extraordinary Report with respect to the action taken related to lesson learned from the Fukushima accident. It includes relevant information for the period of 2010/2012. This document represents the national report prepared as a fulfillment of the brazilian obligations related to the Convention on Nuclear Safety. In chapter 2 some details are given about the existing nuclear installations. Chapter 3 provides details about the legislation and regulations, including the regulatory framework and the regulatory body. Chapter 4 covers general safety considerations as described in articles 10 to 16 of the Convention. Chapter 5 addresses to the safety of the installations during siting, design, construction and operation. Chapter 6 describes planned activities to further enhance nuclear safety. Chapter 7 presents the final remarks related to the degree of compliance with the Convention obligations.

  17. Global climate convention

    International Nuclear Information System (INIS)

    Simonis, U.E.

    1991-01-01

    The effort of negotiate a global convention on climate change is one of mankind's great endeavours - and a challenge to economists and development planners. The inherent linkages between climate and the habitability of the earth are increasingly well recognized, and a convention could help to ensure that conserving the environment and developing the economy in the future must go hand in hand. Due to growing environmental concern the United Nations General Assembly has set into motion an international negotiating process for a framework convention on climate change. One the major tasks in these negotiations is how to share the duties in reducing climate relevant gases, particularly carbon dioxide (CO 2 ), between the industrial and the developing countries. The results and proposals could be among the most far-reaching ever for socio-economic development, indeed for global security and survival itself. While the negotiations will be about climate and protection of the atmosphere, they will be on fundamental global changes in energy policies, forestry, transport, technology, and on development pathways with low greenhouse gas emissions. Some of these aspects of a climate convention, particularly the distributional options and consequences for the North-South relations, are addressed in this chapter. (orig.)

  18. Fourth national report of Brazil for the nuclear safety convention. Sep. 2007

    International Nuclear Information System (INIS)

    2007-09-01

    This Fourth National Report of Brazil is a new update to include relevant information of the period of 2004-2007. This document represents the national report prepared as a fulfillment of the brazilian obligations related to the Convention on Nuclear Safety. In chapter 2 some details are given about the existing nuclear installations. Chapter 3 provides details about the legislation and regulations, including the regulatory framework and the regulatory body. Chapter 4 covers general safety considerations as described in articles 10 to 16 of the Convention. Chapter 5 addresses to the safety of the installations during siting, design, construction and operation. Chapter 6 describes planned activities to further enhance nuclear safety. Chapter 7 presents the final remarks related to the degree of compliance with the Convention obligations

  19. Fourth national report of Brazil for the nuclear safety convention. Sep. 2007

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-09-15

    This Fourth National Report of Brazil is a new update to include relevant information of the period of 2004-2007. This document represents the national report prepared as a fulfillment of the brazilian obligations related to the Convention on Nuclear Safety. In chapter 2 some details are given about the existing nuclear installations. Chapter 3 provides details about the legislation and regulations, including the regulatory framework and the regulatory body. Chapter 4 covers general safety considerations as described in articles 10 to 16 of the Convention. Chapter 5 addresses to the safety of the installations during siting, design, construction and operation. Chapter 6 describes planned activities to further enhance nuclear safety. Chapter 7 presents the final remarks related to the degree of compliance with the Convention obligations

  20. Buffer-free therapeutic antibody preparations provide a viable alternative to conventionally buffered solutions: from protein buffer capacity prediction to bioprocess applications.

    Science.gov (United States)

    Bahrenburg, Sven; Karow, Anne R; Garidel, Patrick

    2015-04-01

    Protein therapeutics, including monoclonal antibodies (mAbs), have significant buffering capacity, particularly at concentrations>50 mg/mL. This report addresses pH-related issues critical to adoption of self-buffered monoclonal antibody formulations. We evaluated solution conditions with protein concentrations ranging from 50 to 250 mg/mL. Samples were both buffer-free and conventionally buffered with citrate. Samples were non-isotonic or adjusted for isotonicity with NaCl or trehalose. Studies included accelerated temperature stability tests, shaking stability studies, and pH changes in infusion media as protein concentrate is added. We present averaged buffering slopes of capacity that can be applied to any mAb and present a general method for calculating buffering capacity of buffer-free, highly concentrated antibody liquid formulations. In temperature stability tests, neither buffer-free nor conventionally buffered solution conditions showed significant pH changes. Conventionally buffered solutions showed significantly higher opalescence than buffer-free ones. In general, buffer-free solution conditions showed less aggregation than conventionally buffered solutions. Shaking stability tests showed no differences between buffer-free and conventionally buffered solutions. "In-use" preparation experiments showed that pH in infusion bag medium can rapidly approximate that of self-buffered protein concentrate as concentrate is added. In summary, the buffer capacity of proteins can be predicted and buffer-free therapeutic antibody preparations provide a viable alternative to conventionally buffered solutions. Copyright © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Using spatial metrics to assess the efficacy of biodiversity conservation within the Romanian Carpathian Convention area

    Directory of Open Access Journals (Sweden)

    Petrişor Alexandru-Ionuţ

    2017-06-01

    Full Text Available The alpine region is of crucial importance for the European Union; as a result, the Carpathian Convention aims at its sustainable development. Since sustainability implies also conservation through natural protected areas, aimed at including regions representative for the national biogeographical space, this article aims at assessing the efficiency of conservation. The methodology consisted of using spatial metrics applied to Romanian and European data on the natural protected areas, land cover and use and their transitional dynamics. The findings show a very good coverage of the Alpine biogeographical region (98% included in the Convention area, and 43% of it protected within the Convention area and of the ecological region of Carpathian montane coniferous forests (88% included in the Convention area, and 42% of it protected within the Convention area. The dominant land cover is represented by forests (63% within the Convention area, and 70% of the total protected area. The main transitional dynamics are deforestation (covering 50% of all changes area within the Convention area and 46% from the changed area within its protected area and forestations – including afforestation, reforestation and colonization of abandoned agricultural areas by forest vegetation (covering 44% of all changes area within the Convention area and 51% from the changed area within its protected area during 1990-2000 and deforestation (covering 97% of all changes area within the Convention area and 99% from the changed area within its protected area during 1990-2000. The results suggest that the coverage of biogeographical and ecological zones is good, especially for the most relevant ones, but deforestations are a serious issue, regardless of occurring before or after achieving the protection status.

  2. Conventional radiotherapy of localized right side breast cancer after radical mastectomy: development of innovative “field in field” technique

    Directory of Open Access Journals (Sweden)

    Goran Marošević

    2011-12-01

    Full Text Available Introduction: The aim of this paper is to study the distribution of the therapy dosage applied by a modified conventional “field in field” technique and compare it to the distribution of the dosage applied by the standard conventional technique.Methods: The study included ten patients with right side breast cancer, after they were exposed to radical mastectomy and chemotherapy. Radiotherapy dosage of TD 50 Gy in 25 fractions was applied to the anterolateral side of the right thoracic wall, with two opposite conventional tangential fields by the linear accelerator Elekta Synergy and the energy of 6 megavolts (MV. A delineation of the target volume (CTV – Clinical Target Volume was done within conventional fields. At the XiO system for planning we included additional fields within the existing conventional fields, which was the so called “field in field” technique. On the basis of CTV the Dose Volume  Histogram (DVH was calculated for conventional and “field in field” plans. VD90%, VD95%, VD107%, VD115%, CI and HI were calculated for both techniques. Means were pared with the paired Student's t-test. The results were considered significantly different if p<0.05.Results: VD90% and VD 95% were significantly higher for the “field in field” technique. Therefore, CI also favored the “field in field” technique (p=0.02. There was no difference in VD107% and VD115% between the compared groups. Consequently, there was no statistically significant difference in HI (1.13±0.03 vs.1.13±0.03, p=0.06.Conclusion: Conventional postoperative radiotherapy of localized right side breast cancer by “field in field” technique provides excellent coverage of the target volume by radiotherapy isodose.

  3. The efficacy of selective calculus ablation at 400 nm: comparison to conventional calculus removal methods

    Science.gov (United States)

    Schoenly, Joshua E.; Seka, Wolf; Romanos, Georgios; Rechmann, Peter

    A desired outcome of scaling and root planing is the complete removal of calculus and infected root tissue and preservation of healthy cementum for rapid healing of periodontal tissues. Conventional periodontal treatments for calculus removal, such as hand instrument scaling and ultrasonic scaling, often deeply scrape the surface of the underlying hard tissue and may leave behind a smear layer. Pulsed lasers emitting at violet wavelengths (specifically, 380 to 400 nm) are a potential alternative treatment since they can selectively ablate dental calculus without ablating pristine hard tissue (i.e., enamel, cementum, and dentin). In this study, light and scanning electron microscopy are used to compare and contrast the efficacy of in vitro calculus removal for several conventional periodontal treatments (hand instruments, ultrasonic scaler, and Er:YAG laser) to calculus removal with a frequency-doubled Ti:sapphire (λ = 400 nm). After calculus removal, enamel and cementum surfaces are investigated for calculus debris and damage to the underlying hard tissue surface. Compared to the smear layer, grooves, and unintentional hard tissue removal typically found using these conventional treatments, calculus removal using the 400-nm laser is complete and selective without any removal of pristine dental hard tissue. Based on these results, selective ablation from the 400-nm laser appears to produce a root surface that would be more suitable for successful healing of periodontal tissues.

  4. Early versus conventional stoma closure following bowel surgery: A randomized controlled trial

    Science.gov (United States)

    Nelson, Thirugnanasambandam; Pranavi, Amuda R.; Sureshkumar, Sathasivam; Sreenath, Gubbi S.; Kate, Vikram

    2018-01-01

    Background/Aim: To compare early stoma closure with conventional stoma closure following defunctioning diversion stoma surgery with respect to the frequency of complications, health-related quality of life (QoL), and length of hospitalization (LoH). Patients and Methods: This study was designed as a prospective parallel-arm randomized controlled trial. Patients who underwent temporary stoma following bowel surgery between February 2014 and November 2015 were included. The rate of complications (medical and surgical) following early and conventional stoma closure was assessed. Health-related QoL and LoH were also measured. Results: One hundred patients were included, with 50 cases in each group. Postoperative complications including laparostoma (6% vs. 2%;P = 0.307), wound infection (32% vs. 18%; P = 0.106), intra-abdominal collection (14% vs. 18%; P = 0.585), anastomotic leak (4%vs. 8%;P = 0.400), and medical complications were comparable (22% vs. 32%;P = 0.257). The length of hospital stay, overall mortality and morbidity (64% vs. 44%; P = 0.05) were similar across the two groups. There was a significant reduction in the cost towards stoma care (96% vs. 2%; P = 0.001) in the early stoma closure group. Patients in the early stoma closure group also had a significantly better QoL. Conclusion: Early stoma closure does not carry an increased risk of postoperative complications, reduces cost towards stoma care, and leads to better a QoL. PMID:29451185

  5. U.S. Perspectives on the Joint Convention

    International Nuclear Information System (INIS)

    Strosnider, J.; Federline, M.; Camper, L.; Abu-Eid, R.; Gnugnoli, G.; Gorn, J.; Bubar, P.; Tonkay, D.

    2006-01-01

    The Joint Convention on the Safety of Spent Fuel Management and on the Safety of Radioactive Waste Management (Joint Convention) is an international convention, under the auspices of the International Atomic Energy Agency (IAEA). It is a companion to a suite of international conventions on nuclear safety and physical security, which serve to promote a global culture for the safe use of radioactive materials. Although the U.S. was the first nation to sign the Joint Convention on September 29, 1997, the ratification process was a challenging experience for the U.S., in the face of legislative priorities dominated by concerns for national security and threats from terrorism after September 11, 2001. Notwithstanding these prevailing circumstances, the U.S. ratified the Joint Convention in 2003, just prior to the First Review Meeting of the Contracting Parties, and participated fully therein. For the United States, participation as a Contracting Party provides many benefits. These range from working with other Parties to harmonize international approaches to achieve strong and effective nuclear safety programs on a global scale, to stimulating initiatives to improve safety systems within our own domestic programs, to learning about technical innovations by other Parties that can be useful to U.S. licensees, utilities, and industry in managing safety and its associated costs in our waste management activities. The Joint Convention process also provides opportunities to identify future areas of bilateral and multilateral technical and regulatory cooperation with other Parties, as well as an opportunity for U.S. vendors and suppliers to broaden their market to include foreign clients for safety improvement equipment and services. The Joint Convention is consistent with U.S. foreign policy considerations to support, as a priority, the strengthening of the worldwide safety culture in the use of nuclear energy. Because of its many benefits, we believe it is important to take

  6. Conventional vs. e-learning in nursing education: A systematic review and meta-analysis.

    Science.gov (United States)

    Voutilainen, Ari; Saaranen, Terhi; Sormunen, Marjorita

    2017-03-01

    By and large, in health professions training, the direction of the effect of e-learning, positive or negative, strongly depends on the learning outcome in question as well as on learning methods which e-learning is compared to. In nursing education, meta-analytically generated knowledge regarding the comparisons between conventional and e-learning is scarce. The aim of this review is to discover the size of the effect of e-learning on learning outcomes in nursing education and to assess the quality of studies in which e-learning has been compared to conventional learning. A systematic search of six electronic databases, PubMed, Ovid MEDLINE®, CINAHL (EBSCOhost), Cochrane Library, PsycINFO, and ERIC, was conducted in order to identify relevant peer-reviewed English language articles published between 2011 and 2015. The quality of the studies included as well as the risk of bias in each study was assessed. A random-effects meta-analysis was performed to generate a pooled mean difference in the learning outcome. Altogether, 10 studies were eligible for the quality assessment and meta-analysis. Nine studies were evaluated as good quality studies, but not without a risk of bias. Performance bias caused a high risk in nearly all the studies. In the meta-analysis, an e-learning method resulted in test scores that were, on average, five points higher than a conventional method on a 0-100 scale. Heterogeneity between the studies was very large. The size and direction of the effect of a learning method on learning outcomes appeared to be strongly situational. We suggest that meta-regressions should be performed instead of basic meta-analyses in order to reveal factors that cause variation in the learning outcomes of nursing education. It might be necessary to perform separate meta-analyses between e-learning interventions aimed at improving nursing knowledge and those aimed at improving nursing skills. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Earthquake analysis of structures including structure-soil interaction by a substructure method

    International Nuclear Information System (INIS)

    Chopra, A.K.; Guttierrez, J.A.

    1977-01-01

    A general substructure method for analysis of response of nuclear power plant structures to earthquake ground motion, including the effects of structure-soil interaction, is summarized. The method is applicable to complex structures idealized as finite element systems and the soil region treated as either a continuum, for example as a viscoelastic halfspace, or idealized as a finite element system. The halfspace idealization permits reliable analysis for sites where essentially similar soils extend to large depths and there is no rigid boundary such as soil-rock interface. For sites where layers of soft soil are underlain by rock at shallow depth, finite element idealization of the soil region is appropriate; in this case, the direct and substructure methods would lead to equivalent results but the latter provides the better alternative. Treating the free field motion directly as the earthquake input in the substructure method eliminates the deconvolution calculations and the related assumption -regarding type and direction of earthquake waves- required in the direct method. The substructure method is computationally efficient because the two substructures-the structure and the soil region- are analyzed separately; and, more important, it permits taking advantage of the important feature that response to earthquake ground motion is essentially contained in the lower few natural modes of vibration of the structure on fixed base. For sites where essentially similar soils extend to large depths and there is no obvious rigid boundary such as a soil-rock interface, numerical results for earthquake response of a nuclear reactor structure are presented to demonstrate that the commonly used finite element method may lead to unacceptable errors; but the substructure method leads to reliable results

  8. Standardizing naming conventions in radiation oncology.

    Science.gov (United States)

    Santanam, Lakshmi; Hurkmans, Coen; Mutic, Sasa; van Vliet-Vroegindeweij, Corine; Brame, Scott; Straube, William; Galvin, James; Tripuraneni, Prabhakar; Michalski, Jeff; Bosch, Walter

    2012-07-15

    The aim of this study was to report on the development of a standardized target and organ-at-risk naming convention for use in radiation therapy and to present the nomenclature for structure naming for interinstitutional data sharing, clinical trial repositories, integrated multi-institutional collaborative databases, and quality control centers. This taxonomy should also enable improved plan benchmarking between clinical institutions and vendors and facilitation of automated treatment plan quality control. The Advanced Technology Consortium, Washington University in St. Louis, Radiation Therapy Oncology Group, Dutch Radiation Oncology Society, and the Clinical Trials RT QA Harmonization Group collaborated in creating this new naming convention. The International Commission on Radiation Units and Measurements guidelines have been used to create standardized nomenclature for target volumes (clinical target volume, internal target volume, planning target volume, etc.), organs at risk, and planning organ-at-risk volumes in radiation therapy. The nomenclature also includes rules for specifying laterality and margins for various structures. The naming rules distinguish tumor and nodal planning target volumes, with correspondence to their respective tumor/nodal clinical target volumes. It also provides rules for basic structure naming, as well as an option for more detailed names. Names of nonstandard structures used mainly for plan optimization or evaluation (rings, islands of dose avoidance, islands where additional dose is needed [dose painting]) are identified separately. In addition to its use in 16 ongoing Radiation Therapy Oncology Group advanced technology clinical trial protocols and several new European Organization for Research and Treatment of Cancer protocols, a pilot version of this naming convention has been evaluated using patient data sets with varying treatment sites. All structures in these data sets were satisfactorily identified using this

  9. Phenolic content and antioxidant capacity in organically and conventionally grown eggplant (Solanum melongena fruits following thermal processing

    Directory of Open Access Journals (Sweden)

    Erika Leonor Zambrano-Moreno

    2015-09-01

    Full Text Available AbstractThermal processing and production practices used in vegetables can cause changes in their phytochemical contents. Eggplant is characterized by its high antioxidant content. The objective of this work was to determine levels of anthocyanins, polyphenols, and flavonoids and antioxidant capacity in organically and conventionally grown eggplant prepared fresh or subjected to one of three thermal preparation methods: boiling, baking or steaming. The soluble and hydrolyzable polyphenols and flavonoids content were quantified by Folin-Ciocalteu and Aluminum chloride methods, respectively. Anthocyanins were quantified according to the pH differential method. Antioxidant capacity was determined by DPPH and ORAC methods. The results showed differences between organic and conventional eggplant for some variables although cultivation method did not have a consistent effect. Hydrolysable polyphenol content was greater, and soluble and hydrolysable antioxidant capacities were higher in organically grown eggplant, while anthocyanin content was greater in conventionally grown eggplant. Fresh eggplant produced under conventional cultivation had a much greater content of anthocyanins compared to that of other cultivation method-thermal treatment combination. In general, steamed eggplant contained higher total polyphenol and flavonoid levels as well as greater antioxidant capacity. Steamed eggplant from both conventional and organic systems also had high amounts of anthocyanins compared to other thermal treatments.

  10. A Comparative Study of Reduced-Variables-Based Flash and Conventional Flash

    DEFF Research Database (Denmark)

    Yan, Wei; Stenby, Erling Halfdan; Michelsen, Michael Locht

    2013-01-01

    ) with zero binary-interaction parameters (BIPs) and later generalized to situations with nonzero-BIP matrices. Most of the studies in the last decade suggest that the reduced-variables methods are much more efficient than the conventional flash method. However, Haugen and Beckner (2011) questioned...... with the conventional minimization-based flash. A test with the use of the SPE 3 example (Kenyon and Behie 1987) showed that the best reduction in time was less than 20% for the extreme situation of 25 components and just one row/column with nonzero BIPs. A better performance can be achieved by a simpler implementation...... directly using the sparsity of the BIP matrix....

  11. Aarhus and Espoo Conventions: The role in promoting effective public participation in nuclear decision-making. The role of the Aarhus and Espoo Conventions in promoting effective public participation in nuclear decision-making

    International Nuclear Information System (INIS)

    Yanush, Maryna; Jendroska, Jerzy

    2017-01-01

    Ms Yanush and Mr Jendroska highlighted the role and importance of the Convention on Access to Information, Public Participation in Decision-Making and Access to Justice in Environmental Matters (the Aarhus Convention) and that of the Convention on Environmental Impact Assessment in a Transboundary Context (the Espoo Convention). These two conventions are open for global accession and, at present, have been ratified mainly by European and Central Asian countries within the United Nations Economic Commission for Europe (UNECE) region. Those two conventions, which apply to a wide range of activities including nuclear, are the only two binding international instruments setting minimum standards for public access to environmental information and public participation in decision making. The Maastricht Recommendations on Promoting Effective Public Participation in Decision-Making in Environmental Matters under the Aarhus Convention and the Good Practice Recommendations on the Application of the Convention to Nuclear Energy-related Activities under the Espoo Convention are instrumental in advancing the implementation in this area. Public participation under the Aarhus Convention goes beyond information or consultation: the decision maker must take into account the views of the 'public concerned' (i.e. the members of the public affected or likely to be affected by the decision making or having an interest in it). As the 'public concerned' is assessed through the potential impact of the proposed activity, including in the case of an accident, the obligation to notify and provide opportunity for public participation is not limited to the territory of the country hosting the proposed activity. Mr Jendroska indicated a particular finding of the Espoo Convention Implementation Committee that decisions regarding modifications, upgrades or extensions to the lifetime/operation of a nuclear installation would be subject to these obligations even though the activity remains exactly

  12. Conventional Complete Denture in Patients with Ectodermal Dysplasia

    Directory of Open Access Journals (Sweden)

    Larissa Soares Reis Vilanova

    2015-01-01

    Full Text Available Ectodermal dysplasia is described as heritable conditions that involve anomalies of structures derived from the ectoderm, including hypodontia. In the cases of edentulous young patients, who did not finish their craniofacial growth, treatment with conventional complete denture is a suitable alternative. The aim of this study was to report a case of mandibular edentulism treated with conventional complete denture in a thirteen-year-old patient diagnosed with hidrotic ectodermal dysplasia. Typical features, such as frontal bossing, depressed nasal bridge, protuberant lips, scarce hair, and brittle nails, were visualized during the extraoral examination. The intraoral inspection and radiographic analysis revealed oligodontia, dental malformation, and prolonged retention of deciduous teeth at maxilla and total edentulism at mandible. A conventional complete denture was planned and constructed following the same steps of technique as recommended in adults. Although this option is not a definitive treatment, the patient and his parents were satisfied with his improvement in chewing and speech, as well as with the aesthetic benefits.

  13. ESD and the Rio Conventions

    Science.gov (United States)

    Sarabhai, Kartikeya V.; Ravindranath, Shailaja; Schwarz, Rixa; Vyas, Purvi

    2012-01-01

    Chapter 36 of Agenda 21, a key document of the 1992 Earth Summit, emphasised reorienting education towards sustainable development. While two of the Rio conventions, the Convention on Biological Diversity (CBD) and the United Nations Framework Convention on Climate Change (UNFCCC), developed communication, education and public awareness (CEPA)…

  14. Three types of children’s informational web sites: an inventory of design conventions

    NARCIS (Netherlands)

    Jochmann-Mannak, Hanna; Lentz, Leo; Huibers, Theo W.C.; Sanders, Ted

    2012-01-01

    "Purpose: Research on Web design conventions has an almost exclusive focus on Web design for adults. There is far less knowledge about Web design for children. For the first time, an overview is presented of the current design conventions for children's informational Web sites. Method: In this study

  15. Conventional and Non-Conventional Yeasts in Beer Production

    Directory of Open Access Journals (Sweden)

    Angela Capece

    2018-06-01

    Full Text Available The quality of beer relies on the activity of fermenting yeasts, not only for their good fermentation yield-efficiency, but also for their influence on beer aroma, since most of the aromatic compounds are intermediate metabolites and by-products of yeast metabolism. Beer production is a traditional process, in which Saccharomyces is the sole microbial component, and any deviation is considered a flaw. However, nowadays the brewing sector is faced with an increasing demand for innovative products, and it is diffusing the use of uncharacterized autochthonous starter cultures, spontaneous fermentation, or non-Saccharomyces starters, which leads to the production of distinctive and unusual products. Attempts to obtain products with more complex sensory characteristics have led one to prospect for non-conventional yeasts, i.e., non-Saccharomyces yeasts. These generally are characterized by low fermentation yields and are more sensitive to ethanol stress, but they provide a distinctive aroma and flavor. Furthermore, non-conventional yeasts can be used for the production of low-alcohol/non-alcoholic and light beers. This review aims to present the main findings about the role of traditional and non-conventional yeasts in brewing, demonstrating the wide choice of available yeasts, which represents a new biotechnological approach with which to target the characteristics of beer and to produce different or even totally new beer styles.

  16. Ultrasound-assisted extraction of natural antioxidants from the flower of Limonium sinuatum: Optimization and comparison with conventional methods.

    Science.gov (United States)

    Xu, Dong-Ping; Zheng, Jie; Zhou, Yue; Li, Ya; Li, Sha; Li, Hua-Bin

    2017-02-15

    Natural antioxidants are widely used as dietary supplements or food additives. An optimized method of ultrasound-assisted extraction (UAE) was proposed for the effective extraction of antioxidants from the flowers of Limonium sinuatum and evaluated by response surface methodology. In this study, ethanol concentration, ratio of solvent to solid, ultrasonication time and temperature were investigated and optimized using a central composite rotatable design. The optimum extraction conditions were as follows: ethanol concentration, 60%; ratio of solvent to solid, 56.9:1mL/g; ultrasonication time, 9.8min; and temperature, 40°C. Under the optimal UAE conditions, the experimental values (483.01±15.39μmolTrolox/gDW) matched with those predicted (494.13μmolTrolox/gDW) within a 95% confidence level. In addition, the antioxidant activities of UAE were compared with those of conventional maceration and Soxhlet extraction methods, and the ultrasound-assisted extraction could give higher yield of antioxidants and markedly reduce the extraction time. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Determinants of Liquidity Risk in Indonesian Islamic and Conventional Banks

    Directory of Open Access Journals (Sweden)

    Raditya Sukmana

    2016-07-01

    Full Text Available The purpose of the study is to examine the causes of the liquidity risk  in Islamic and conventional banks in Indonesia using panel data regression method. The study found the significant and positive relation of ROA and NPF with the liquidity risk, whereas the negative and significant relation of CAR with the liquidity risk in Indonesian Conventional Banks. Meanwhile in Islamic banks, CAR result significantly positive effect on liquidity risk, while ROA shows negative and significant result. Possible explanation for this is that, given the huge profit by the conventional banks, it has more chance to allocate it as liquidity reserve as well as increasing the facilities (improvement on technology. When the NPL is high, conventional banks will increase the liquid assets as a buffer. Unlike that of conventional banks, the Islamic banks in Indonesia might allocate capital as liquidity reserves and might allocate ROA in fixed assets or financing or technology. The result confirm that the role of capital and bank’s performance in indeed important to the banking liquidityDOI: 10.15408/aiq.v8i2.2871

  18. Implementation of a new rapid tissue processing method--advantages and challenges

    DEFF Research Database (Denmark)

    Munkholm, Julie; Talman, Maj-Lis; Hasselager, Thomas

    2008-01-01

    Conventional tissue processing of histologic specimens has been carried out in the same manner for many years. It is a time-consuming process involving batch production, resulting in a 1-day delay of the diagnosis. Microwave-assisted tissue processing enables a continuous high flow of histologic...... specimens through the processor with a processing time of as low as 1h. In this article, we present the effects of the automated microwave-assisted tissue processor on the histomorphologic quality and the turnaround time (TAT) for histopathology reports. We present a blind comparative study regarding...... the histomorphologic quality of microwave-processed and conventionally processed tissue samples. A total of 333 specimens were included. The microwave-assisted processing method showed a histomorphologic quality comparable to the conventional method for a number of tissue types, including skin and specimens from...

  19. User requirement analysis of social conventions learning applications for Non-natives and low-literates

    NARCIS (Netherlands)

    Schouten, D.; Smets, N.; Driessen, M.; Hanekamp, M.; Cremers, A.H.M.; Neerincx, M.A.

    2013-01-01

    Learning and acting on social conventions is problematic for low-literates and non-natives, causing problems with societal participation and citizenship. Using the Situated Cognitive Engineering method, requirements for the design of social conventions learning software are derived from demographic

  20. Digitization of conventional radiographs

    International Nuclear Information System (INIS)

    Wenz, W.; Buitrago-Tellez, C.; Blum, U.; Hauenstein, K.H.; Gufler, H.; Meyer, E.; Ruediger, K.

    1992-01-01

    The diagnostic value of a digitization system for analogue films based on a charge-coupled-device (CCD) scanner with adjustable resolution of 2.5 or 5 lp/mm was assessed. Some 110 skeletal radiographs, 50 contrast studies, including 25 of patients with Crohn's disease, and 70 abdominal plain films before and after successful lithotripsy for renal stones were digitized. Receiver operating characteristic (ROC) studies showed improved detection of cortical and trabecular defects with contrast-optimized digitized films. Edge enhancement algorithms yielded no additional information. Inflammatory lesions of Crohn's disease were detected equally well by conventional films and digitized images. A statistically significant improvement (p [de

  1. Conventional magnets. Pt. 1

    International Nuclear Information System (INIS)

    Marks, N.

    1994-01-01

    The design and construction of conventional, steel-cored, direct-current magnets are discussed. Laplace's equation and the associated cylindrical harmonic solutions in two dimensions are established. The equations are used to define the ideal pole shapes and required excitation for dipole, quadrupole and sextupole magnets. Standard magnet geometries are then considered and criteria determining the coil design are presented. The use of codes for predicting flux density distributions and the iterative techniques used for pole face design are then discussed. This includes a description of the use of two-dimensional codes to generate suitable magnet end geometries. Finally, standard constructional techniques for cores and coils are described. (orig.)

  2. Limits of radiobiology in conventional postirradiation of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    van der Wall, H [Bezirkskrankenhaus Schwerin (German Democratic Republic)

    1982-08-01

    The conventional postirradiation of breast cancer including radiation pneumonitis in relation to age and irradiation method, are discussed. The risk of radiation pneumonitis is with a single surface dose of 65 mC/kg higher than with 52 mC/kg. The dose at the chest wall is for the development of a radiation pneumonitis of lower importance than the dose at the supra- and intraclavicular field. At both these fields intersections of the cones of radiation in the lungs, which could cause dose peaks not possible to evaluate, must be taken into consideration. At the reported and wanted tumor dose of 1032 mC/kg at the deferent axillary lymph tracts a more indulgent method with a single dose of 65 mC/kg and with a prolongation by 3 series a pneumonitis could not be avoided in 30% of the irradiated women. Because of the harmless process one could answer for the risk of a radiation pneumonitis, if other therapeutic possibilities are not available. The age of the patients is not a special risk as to radiation pneumonitis.

  3. Limits of radiobiology in conventional postirradiation of breast cancer

    International Nuclear Information System (INIS)

    Wall, H. van der

    1982-01-01

    The conventional postirradiation of breast cancer including radiation pneumonitis in relation to age and irradiation method, are discussed. The risk of radiation pneumonitis is with a single surface dose of 65 mC/kg higher than with 52 mC/kg. The dose at the chest wall is for the development of a radiation pneumonitis of lower importance than the dose at the supra- and intraclavicular field. At both these fields intersections of the cones of radiation in the lungs, which could cause dose peaks not possible to evaluate, must be taken into consideration. At the reported and wanted tumor dose of 1032 mC/kg at the deferent axillary lymph tracts a more indulgent method with a single dose of 65 mC/kg and with a prolongation by 3 series a pneumonitis could not be avoided in 30% of the irradiated women. Because of the harmless process one could answer for the risk of a radiation pneumonitis, if other therapeutic possibilities are not available. The age of the patients is not a special risk as to radiation pneumonitis. (author)

  4. Conventional operation and laser therapy in the treatment of varicose veins

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Objective: To evaluate the effectiveness of endovenous laser therapy and conventional therapy on the varicose of great saphenous vein. Methods: Thirty-two patients received endovenous laser therapy and 32 patients were operated by conventional therapy (high ligation and stripping). The observation results of great saphenous vein(GSV) were recorded by clinical evaluation and duplex ultrasound examination. And the operating time, intraoperative blood loss, time to become moveable, duration of hospitalization and degree of feeling pain were compared between the two groups. Results: Compared with conventional therapy, laser therapy had good curative effect with less complications and no scars and no pains. There were significant differences between the two groups (P<0.01). Conclusion: Laser therapy for varicose of great saphenous vein is better than the conventional therapy. It deserves to be widely used in clinical treatment.

  5. Computer simulations of the influence of geometry in the performance of conventional and unconventional lithium-ion batteries

    International Nuclear Information System (INIS)

    Miranda, D.; Costa, C.M.; Almeida, A.M.; Lanceros-Méndez, S.

    2016-01-01

    Highlights: • The influence of geometries in lithium-ion battery performance is analyzed. • Conventional and unconventional battery geometries are investigated. • Unconventional geometries include horseshoe, spiral, ring, antenna and gear batteries. • The best capacity value at 330 C is obtained for the interdigitated geometry. • The capacity value is dependent on thickness and collectors position. - Abstract: In order to optimize battery performance, different geometries have been evaluated taking into account their suitability for different applications. These different geometries include conventional, interdigitated batteries and unconventional geometries such as horseshoe, spiral, ring, antenna and gear batteries. The geometry optimization was performed by the finite element method, applying the Doyle/Fuller/Newman model. At 330 C, the capacity values for conventional, ring, spiral, horseshoe, gear and interdigitated geometries are 0.58 A h m"−"2, 149 A h m"−"2, 182 A h m"−"2, 216 A h m"−"2, 289 A h m"−"2 and 318 A h m"−"2, respectively. The delivered capacity depends on geometrical parameters such as maximum distance for the ions to move to the current collector, d-max, distance between of current collectors, d-cc, as well as the thickness of separator and electrodes, allowing to tailor battery performance and geometry for specific applications.

  6. Comparison of different methods to include recycling in LCAs of aluminium cans and disposable polystyrene cups

    NARCIS (Netherlands)

    Harst-Wintraecken, van der Eugenie; Potting, José; Kroeze, Carolien

    2016-01-01

    Many methods have been reported and used to include recycling in life cycle assessments (LCAs). This paper evaluates six widely used methods: three substitution methods (i.e. substitution based on equal quality, a correction factor, and alternative material), allocation based on the number of

  7. Pain score of patients undergoing single spot, short pulse laser versus conventional laser for diabetic retinopathy.

    Science.gov (United States)

    Mirshahi, Ahmad; Lashay, Alireza; Roozbahani, Mehdi; Fard, Masoud Aghsaei; Molaie, Saber; Mireshghi, Meysam; Zaferani, Mohamad Mehdi

    2013-04-01

    To compare pain score of single spot short duration time (20 milliseconds) panretinal photocoagulation (PRP) with conventional (100 milliseconds) PRP in diabetic retinopathy. Sixty-six eyes from 33 patients with symmetrical severe non-proliferative diabetic retinopathy (non-PDR) or proliferative diabetic retinopathy (PDR) were enrolled in this prospective randomized controlled trial. One eye of each patient was randomized to undergo conventional and the other eye to undergo short time PRP. Spot size of 200 μm was used in both laser types, and energy was adjusted to achieve moderate burn on the retina. Patients were asked to mark the level of pain felt during the PRP session for each eye on the visual analog scale (VAS) and were examined at 1 week, and at 1, 2, 4 and 6 months. Sixteen women and 17 men with mean age 58.9 ± 7.8 years were evaluated. The conventional method required a mean power of 273 ± 107 mW, whereas the short duration method needed 721 ± 406 mW (P = 0.001). An average of 1,218 ± 441 spots were delivered with the conventional method and an average of 2,125 ± 503 spots were required with the short duration method (P = 0.001). Average pain score was 7.5 ± 1.14 in conventional group and 1.75 ± 0.87 in the short duration group (P = 0.001). At 1 week, 1 month, and 4 months following PRP, the mean changes of central macular thickness (CMT) from baseline in the conventional group remained 29.2 μm (P = 0.008), 40.0 μm (P = 0.001), and 40.2 μm (P = 0.007) greater than the changes in CMT for short time group. Patient acceptance of short time single spot PRP was high, and well-tolerated in a single session by all patients. Moreover, this method is significantly less painful than but just as effective as conventional laser during 6 months of follow-up. The CMT change was more following conventional laser than short time laser.

  8. Comparison of LED and Conventional Fluorescence Microscopy for Detection of Acid Fast Bacilli in a Low-Incidence Setting

    Science.gov (United States)

    Minion, Jessica; Pai, Madhukar; Ramsay, Andrew; Menzies, Dick; Greenaway, Christina

    2011-01-01

    Introduction Light emitting diode fluorescence microscopes have many practical advantages over conventional mercury vapour fluorescence microscopes, which would make them the preferred choice for laboratories in both low- and high-resource settings, provided performance is equivalent. Methods In a nested case-control study, we compared diagnostic accuracy and time required to read slides with the Zeiss PrimoStar iLED, LW Scientific Lumin, and a conventional fluorescence microscope (Leica DMLS). Mycobacterial culture was used as the reference standard, and subgroup analysis by specimen source and organism isolated were performed. Results There was no difference in sensitivity or specificity between the three microscopes, and agreement was high for all comparisons and subgroups. The Lumin and the conventional fluorescence microscope were equivalent with respect to time required to read smears, but the Zeiss iLED was significantly time saving compared to both. Conclusions Light emitting diode microscopy should be considered by all tuberculosis diagnostic laboratories, including those in high income countries, as a replacement for conventional fluorescence microscopes. Our findings provide support to the recent World Health Organization policy recommending that conventional fluorescence microscopy be replaced by light emitting diode microscopy using auramine staining in all settings where fluorescence microscopy is currently used. PMID:21811622

  9. Comparison of LED and conventional fluorescence microscopy for detection of acid fast bacilli in a low-incidence setting.

    Directory of Open Access Journals (Sweden)

    Jessica Minion

    Full Text Available INTRODUCTION: Light emitting diode fluorescence microscopes have many practical advantages over conventional mercury vapour fluorescence microscopes, which would make them the preferred choice for laboratories in both low- and high-resource settings, provided performance is equivalent. METHODS: In a nested case-control study, we compared diagnostic accuracy and time required to read slides with the Zeiss PrimoStar iLED, LW Scientific Lumin, and a conventional fluorescence microscope (Leica DMLS. Mycobacterial culture was used as the reference standard, and subgroup analysis by specimen source and organism isolated were performed. RESULTS: There was no difference in sensitivity or specificity between the three microscopes, and agreement was high for all comparisons and subgroups. The Lumin and the conventional fluorescence microscope were equivalent with respect to time required to read smears, but the Zeiss iLED was significantly time saving compared to both. CONCLUSIONS: Light emitting diode microscopy should be considered by all tuberculosis diagnostic laboratories, including those in high income countries, as a replacement for conventional fluorescence microscopes. Our findings provide support to the recent World Health Organization policy recommending that conventional fluorescence microscopy be replaced by light emitting diode microscopy using auramine staining in all settings where fluorescence microscopy is currently used.

  10. The EU Arbitration Convention : An evaluating assessment of the governance and functioning of the EU Arbitration Convention

    NARCIS (Netherlands)

    Pit, Harm Mark

    2017-01-01

    The EU Arbitration Convention An evaluating assessment of the governance and functioning of the EU Arbitration Convention Summary for non-experts The EU Arbitration Convention is a convention between EU Member States to eliminate double taxation arising from – for tax purposes – transfer pricing

  11. In vivo evaluation of inter-operator reproducibility of digital dental and conventional impression techniques

    Science.gov (United States)

    Kamimura, Emi; Tanaka, Shinpei; Takaba, Masayuki; Tachi, Keita; Baba, Kazuyoshi

    2017-01-01

    Purpose The aim of this study was to evaluate and compare the inter-operator reproducibility of three-dimensional (3D) images of teeth captured by a digital impression technique to a conventional impression technique in vivo. Materials and methods Twelve participants with complete natural dentition were included in this study. A digital impression of the mandibular molars of these participants was made by two operators with different levels of clinical experience, 3 or 16 years, using an intra-oral scanner (Lava COS, 3M ESPE). A silicone impression also was made by the same operators using the double mix impression technique (Imprint3, 3M ESPE). Stereolithography (STL) data were directly exported from the Lava COS system, while STL data of a plaster model made from silicone impression were captured by a three-dimensional (3D) laboratory scanner (D810, 3shape). The STL datasets recorded by two different operators were compared using 3D evaluation software and superimposed using the best-fit-algorithm method (least-squares method, PolyWorks, InnovMetric Software) for each impression technique. Inter-operator reproducibility as evaluated by average discrepancies of corresponding 3D data was compared between the two techniques (Wilcoxon signed-rank test). Results The visual inspection of superimposed datasets revealed that discrepancies between repeated digital impression were smaller than observed with silicone impression. Confirmation was forthcoming from statistical analysis revealing significantly smaller average inter-operator reproducibility using a digital impression technique (0.014± 0.02 mm) than when using a conventional impression technique (0.023 ± 0.01 mm). Conclusion The results of this in vivo study suggest that inter-operator reproducibility with a digital impression technique may be better than that of a conventional impression technique and is independent of the clinical experience of the operator. PMID:28636642

  12. Imaging methods in otorhinolaryngology

    International Nuclear Information System (INIS)

    Frey, K.W.; Mees, K.; Vogl, T.

    1989-01-01

    This book is the work of an otorhinolaryngologist and two radiologists, who combined their experience and efforts in order to solve a great variety and number of problems encountered in practical work, taking into account the latest technical potentials and the practical feasibility, which is determined by the equipment available. Every chapter presents the full range of diagnostic methods applicable, starting with the suitable plain radiography methods and proceeding to the various tomographic scanning methods, including conventional tomography. Every technique is assessed in terms of diagnostic value and drawbacks. (orig./MG) With 778 figs [de

  13. Randomized controlled within-subject evaluation of digital and conventional workflows for the fabrication of lithium disilicate single crowns. Part I: digital versus conventional unilateral impressions.

    Science.gov (United States)

    Benic, Goran I; Mühlemann, Sven; Fehmer, Vincent; Hämmerle, Christoph H F; Sailer, Irena

    2016-11-01

    Trials comparing the overall performance of fully digital and conventional workflows in reconstructive dentistry are needed. The purpose of the first part of this randomized controlled clinical trial was to determine whether optical impressions produce different results from conventional impressions with respect to time efficiency and patient and operator perceptions of the clinical workflow. Three digital impressions and 1 conventional impression were made in each of 10 participants according to a randomly generated sequence. The digital systems were Lava COS, iTero, and Cerec Bluecam. The conventional impression was made with the closed-mouth technique and polyvinyl siloxane material. The time needed for powdering, impressions, and interocclusal record was recorded. Patient and clinician perceptions of the procedures were rated by means of visual analog scales. The paired t test with Bonferroni correction was applied to detect differences (α=.05/6=.0083). The mean total working time ±standard deviation amounted to 260 ±66 seconds for the conventional impression, 493 ±193 seconds for Lava, 372 ±126 seconds for iTero, and 357 ±55 seconds for Cerec. The total working time for the conventional impression was significantly lower than that for Lava and Cerec. With regard to the working time without powdering, the differences between the methods were not statistically significant. The patient rating (very uncomfortable=0; comfortable=100) measured 61 ±34 for conventional impression, 71 ±18 for Lava, 66 ±20 for iTero, and 48 ±18 for Cerec. The differences were not statistically significant. The clinician rating (simple=0; very difficult=100) was 13 ±13 for the conventional impression, 54 ±27 for Lava, 22 ±11 for iTero, and 36 ±23 for Cerec. The differences between the conventional impression and Lava and between iTero and Lava were statistically significant. The conventional impression was more time-effective than the digital impressions. In terms of

  14. Plasma gasification process: Modeling, simulation and comparison with conventional air gasification

    International Nuclear Information System (INIS)

    Janajreh, Isam; Raza, Syed Shabbar; Valmundsson, Arnar Snaer

    2013-01-01

    Highlights: ► Plasma/conventional gasification are modeled via Gibbs energy minimization. ► The model is applied to wide range of feedstock, tire, biomass, coal, oil shale. ► Plasma gasification show high efficiency for tire waste and coal. ► Efficiency is around 42% for plasma and 72% for conventional gasification. ► Lower plasma gasification efficiency justifies hazardous waste energy recovery. - Abstract: In this study, two methods of gasification are developed for the gasification of various feedstock, these are plasma gasification and conventional air gasification. The two methods are based on non-stoichiometric Gibbs energy minimization approach. The model takes into account the different type of feedstocks, which are analyzed at waste to energy lab at Masdar Institute, oxidizer used along with the plasma energy input and accurately evaluates the syngas composition. The developed model is applied for several types of feedstock, i.e. waste tire material, coal, plywood, pine needles, oil shale, and municipal solid waste (MSW), algae, treated/untreated wood, instigating air/steam as the plasma gas and only air as oxidizer for conventional gasification. The results of plasma gasification and conventional air gasification are calculated on the bases of product gas composition and the process efficiency. Results of plasma gasification shows that high gasification efficiency is achievable using both tire waste material and coal, also, the second law efficiency is calculated for plasma gasification that shows a relative high efficiency for tire and coal as compare to other feedstock. The average process efficiency for plasma gasification is calculated to be around 42%. On other hand the result of conventional gasification shows an average efficiency of 72%. The low efficiency of plasma gasification suggest that if only the disposal of hazard waste material is considered then plasma gasification can be a viable option to recover energy.

  15. Game-based e-learning is more effective than a conventional instructional method: a randomized controlled trial with third-year medical students.

    Directory of Open Access Journals (Sweden)

    Martin Boeker

    Full Text Available BACKGROUND: When compared with more traditional instructional methods, Game-based e-learning (GbEl promises a higher motivation of learners by presenting contents in an interactive, rule-based and competitive way. Most recent systematic reviews and meta-analysis of studies on Game-based learning and GbEl in the medical professions have shown limited effects of these instructional methods. OBJECTIVES: To compare the effectiveness on the learning outcome of a Game-based e-learning (GbEl instruction with a conventional script-based instruction in the teaching of phase contrast microscopy urinalysis under routine training conditions of undergraduate medical students. METHODS: A randomized controlled trial was conducted with 145 medical students in their third year of training in the Department of Urology at the University Medical Center Freiburg, Germany. 82 subjects where allocated for training with an educational adventure-game (GbEl group and 69 subjects for conventional training with a written script-based approach (script group. Learning outcome was measured with a 34 item single choice test. Students' attitudes were collected by a questionnaire regarding fun with the training, motivation to continue the training and self-assessment of acquired knowledge. RESULTS: The students in the GbEl group achieved significantly better results in the cognitive knowledge test than the students in the script group: the mean score was 28.6 for the GbEl group and 26.0 for the script group of a total of 34.0 points with a Cohen's d effect size of 0.71 (ITT analysis. Attitudes towards the recent learning experience were significantly more positive with GbEl. Students reported to have more fun while learning with the game when compared to the script-based approach. CONCLUSIONS: Game-based e-learning is more effective than a script-based approach for the training of urinalysis in regard to cognitive learning outcome and has a high positive motivational impact on

  16. A comparison study on the densification behavior and mechanical properties of gelcast vs conventionally formed B4C sintered conventionally and by microwaves

    International Nuclear Information System (INIS)

    Menchhofer, P.A.; Kiggans, J.O.; Morrow, M.S.; Schechter, D.E.

    1996-01-01

    The utilization of microwave energy for reaching high temperatures necessary to densify B 4 C powder is compared with conventional means of sintering by evaluating the mechanical properties after densification. Microwave energy has been shown to be an effective means for achieving high sintered densities, even though temperatures of ∼ 2,250 C are required. In this study, green preforms of B 4 C specimens were sintered by both conventional and microwave heating. This study also utilized an advanced forming method called ''Gelcasting'' developed at ORNL. Gelcasting is a fluid forming process whereby high solids suspensions of powders containing dissolved monomers are cast into a mold, then polymerized or ''gelled'' in situ. This investigation compares microstructures and mechanical properties of both Gelcast B 4 C and ''conventionally'' die-pressed B 4 C. The microstructures and final mechanical properties of B 4 C specimens are discussed

  17. Conventional U-Pb dating versus SHRIMP of the Santa Barbara Granite Massif, Rondonia, Brazil

    Science.gov (United States)

    Sparrenberger, I.; Bettencourt, Jorge S.; Tosdal, R.M.; Wooden, J.L.

    2002-01-01

    The Santa Ba??rbara Granite Massif is part of the Younger Granites of Rondo??nia (998 - 974 Ma) and is included in the Rondo??nia Tin Province (SW Amazonian Craton). It comprises three highly fractionated metaluminous to peraluminous within-plate A-type granite units emplaced in older medium-grade metamorphic rocks. Sn-mineralization is closely associated with the late-stage unit. U-Pb monazite conventional dating of the early-stage Serra do Cicero facies and late-stage Serra Azul facies yielded ages of 993 ?? 5 Ma and 989 ?? 13 Ma, respectively. Conventional multigrain U-Pb isotope analyses of zircon demonstrate isotopic disturbance (discordance) and the preservation of inherited older zircons of several different ages and thus yield little about the ages of Sn-granite magmatism. SHRIMP U-Pb ages for the Santa Ba??rbara facies association yielded a 207Pb/206Pb weighted-mean age of 978 ?? 13 Ma. The textural complexity of the zircon crystals of the Santa Ba??rbara facies association, the variable concentrations of U, Th and Pb, as well as the mixed inheritance of zircon populations are major obstacles to using conventional multigrain U-Pb isotopic analyses. Sm-Nd model ages and ??Nd (T) values reveal anomalous isotopic data, attesting to the complex isotopic behaviour within these highly fractionated granites. Thus, SHRIMP U-Pb zircon and conventional U-Pb monazite dating methods are the most appropriate to constrain the crystallization age of the Sn-bearing granite systems in the Rondo??nia Tin Province.

  18. IAEA Director General welcomes landmark convention to combat nuclear terrorism

    International Nuclear Information System (INIS)

    2005-01-01

    Full text: IAEA Director General Mohamed ElBaradei welcomed the adoption of an International convention against nuclear terrorism. 'This is a landmark achievement which will bolster global efforts to combat nuclear terrorism,' Dr. ElBaradei said. 'It will be a key part of international efforts to prevent terrorists from gaining access to nuclear weapons'. The United Nations General Assembly adopted the convention, The International Convention for the Suppression of Acts of Nuclear Terrorism, on 13 April 2005. The Convention strengthens the global legal framework to counter terrorist threats. Based on a proposal by the Russian Federation in 1998, the Convention focuses on criminal offences related to nuclear terrorism and covers a broad range of possible targets, including nuclear reactors as well as nuclear material and radioactive substances. Under its provisions, alleged offenders - for example any individual or group that unlawfully and intentionally possesses or uses radioactive material with the intent to cause harm - must be either extradited or prosecuted. States are also encouraged to cooperate with each other in connection with criminal investigations and extradition proceedings. The Convention further requires that any seized nuclear or radiological material be held in accordance with IAEA safeguards, and handled in keeping with the IAEA's health, safety and physical protection standards. Dr. ElBaradei also recalled that the Agency is in the process of amending the Convention on the Physical Protection of Nuclear Material, in order to broaden its scope, and in so doing, strengthen the current legal framework for securing nuclear material against illicit uses. A conference will be held from 4 to 8 July in Vienna to consider and adopt the amendments. The Convention opens for signature in September this year. Dr ElBaradei urged all States to 'sign and ratify the Convention without delay so nuclear terrorism will have no chance'. (IAEA)

  19. The economics of developing non-conventional reserves

    International Nuclear Information System (INIS)

    Kuuskraa, V.A.

    1997-01-01

    A fact-based perspective on the economics of non-conventional natural gas reserves such as coalbed methane, gas shales and tight gas was presented. Traditionally, tax credits stimulate the development of non-conventional gas. Although tax credits for non-conventional gas development stopped at the end of 1992, because of improved technologies, improved finding rates and well productivities, non-conventional reserves continue to play a major role in the U.S. gas drilling development. Non-conventional reserves account for three out of five gas wells drilled in the U.S. The non-conventional gas industry competes directly with the conventional natural gas industry. This paper examined how well non-conventional gas compares to the current replacement costs of conventional natural gas. Investment costs for a non-conventional operation were studied, illustrated by an overview of the costs and economics of non-conventional reserves in the San Juan coal basin, the Piceance tight gas basin and the Michigan and Ft. Worth gas shales basins. 9 tabs

  20. Opportunities for utilization of non-conventional energy sources for biomass pretreatment.

    Science.gov (United States)

    Singh, Rawel; Krishna, Bhavya B; Kumar, Jitendra; Bhaskar, Thallada

    2016-01-01

    The increasing concerns over the depletion of fossil resources and its associated geo-political issues have driven the entire world to move toward sustainable forms of energy. Pretreatment is the first step in any biochemical conversion process for the production of valuable fuels/chemicals from lignocellulosic biomass to eliminate the lignin and produce fermentable sugars by hydrolysis. Conventional techniques have several limitations which can be addressed by using them in tandem with non-conventional methods for biomass pretreatment. Electron beam and γ (gamma)-irradiation, microwave and ultrasound energies have certain advantages over conventional source of energy and there is an opportunity that these energies can be exploited for biomass pretreatment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Adjuvant radiotherapy for cutaneous melanoma: Comparing hypofractionation to conventional fractionation

    International Nuclear Information System (INIS)

    Chang, Daniel T.; Amdur, Robert J.; Morris, Christopher G. M.S.; Mendenhall, William M.

    2006-01-01

    Purpose: To examine locoregional control after adjuvant radiotherapy (RT) for cutaneous melanoma and compare outcomes between conventional fractionation and hypofractionation. Methods and Materials: Between January 1980 and June 2004, 56 patients with high-risk disease were treated with adjuvant RT. Indications for RT included: recurrent disease, cervical lymph node involvement, lymph nodes >3 cm, more than three lymph nodes involved, extracapsular extension, gross residual disease, close or positive margins, or satellitosis. Hypofractionation was used in 41 patients (73%) and conventional fractionation was used in 15 patients (27%). Results: The median age was 61 years (21->90). The median follow-up among living patients was 4.4 years (range, 0.6-14.4 years). The primary site was located in the head and neck in 49 patients (87%) and below the clavicles in 7 patients (13%). There were 7 in-field locoregional failures (12%), 3 out-of-field regional failures (5%), and 24 (43%) distant failures. The 5-year in-field locoregional control (ifLRC) and freedom from distant metastases (FFDM) rates were 87% and 43%, respectively. The 5-year cause-specific (CSS) and overall survival (OS) was 57% and 46%, respectively. The only factor associated with ifLRC was satellitosis (p = 0.0002). Nodal involvement was the only factor associated with FFDM (p = 0.0007), CSS (p = 0.0065), and OS (p = 0.016). Two patients (4%) who experienced severe late complications, osteoradionecrosis of the temporal bone and radiation plexopathy, and both received hypofractionation (5%). Conclusions: Although surgery and adjuvant RT provides excellent locoregional control, distant metastases remain the major cause of mortality. Hypofractionation and conventional fractionation are equally efficacious

  2. Positron range in PET imaging: non-conventional isotopes

    International Nuclear Information System (INIS)

    Jødal, L; Le Loirec, C; Champion, C

    2014-01-01

    In addition to conventional short-lived radionuclides, longer-lived isotopes are becoming increasingly important to positron emission tomography (PET). The longer half-life both allows for circumvention of the in-house production of radionuclides, and expands the spectrum of physiological processes amenable to PET imaging, including processes with prohibitively slow kinetics for investigation with short-lived radiotracers. However, many of these radionuclides emit ‘high-energy’ positrons and gamma rays which affect the spatial resolution and quantitative accuracy of PET images. The objective of the present work is to investigate the positron range distribution for some of these long-lived isotopes. Based on existing Monte Carlo simulations of positron interactions in water, the probability distribution of the line of response displacement have been empirically described by means of analytic displacement functions. Relevant distributions have been derived for the isotopes 22 Na, 52 Mn, 89 Zr, 45 Ti, 51 Mn, 94m Tc, 52m Mn, 38 K, 64 Cu, 86 Y, 124 I, and 120 I. It was found that the distribution functions previously found for a series of conventional isotopes (Jødal et al 2012 Phys. Med. Bio. 57 3931–43), were also applicable to these non-conventional isotopes, except that for 120 I, 124 I, 89 Zr, 52 Mn, and 64 Cu, parameters in the formulae were less well predicted by mean positron energy alone. Both conventional and non-conventional range distributions can be described by relatively simple analytic expressions. The results will be applicable to image-reconstruction software to improve the resolution. (paper)

  3. Microwave heat treatment as a substitute for conventional treatment of palm oil fruits

    International Nuclear Information System (INIS)

    Mujahid H Al-Fayadh; Nor Azura Masabbir Ali

    1996-01-01

    Microwave energy has become a sound method of heat treatment because of its high penetration power, cleanliness and possible economic significance. In this research, microwave heat was used as a substitute for conventional blanching method of palm oil fruits. Microwave treatment at 2450 MHz and 800 watts gave very close color and frn,frying characteristics to oil of blanched fruits after one minute exposure time. However, five minutes of microwave heat gave severe husk oil discoloration after 49 hours of deep frying, compared to all oils extracted from fruits treated by either low, microwave exposure time or conventional steam treatment. Kernel oil, after five minutes of microwave treatment, was less discolored than both steam or microwave-treated fruits for one minute. More carotenes and discoloration compounds may be contributed to discoloration during microwave treatments. Oil chemical constants of both husk and kernel oils treated by microwave heat were close to those treated by conventional heat. Further research is needed to investigate detailed oil characteristics and evaluate the feasibility study for using microwave energy, as a substitute for conventional heat in palm oil industry

  4. Scalable parallel elastic-plastic finite element analysis using a quasi-Newton method with a balancing domain decomposition preconditioner

    Science.gov (United States)

    Yusa, Yasunori; Okada, Hiroshi; Yamada, Tomonori; Yoshimura, Shinobu

    2018-04-01

    A domain decomposition method for large-scale elastic-plastic problems is proposed. The proposed method is based on a quasi-Newton method in conjunction with a balancing domain decomposition preconditioner. The use of a quasi-Newton method overcomes two problems associated with the conventional domain decomposition method based on the Newton-Raphson method: (1) avoidance of a double-loop iteration algorithm, which generally has large computational complexity, and (2) consideration of the local concentration of nonlinear deformation, which is observed in elastic-plastic problems with stress concentration. Moreover, the application of a balancing domain decomposition preconditioner ensures scalability. Using the conventional and proposed domain decomposition methods, several numerical tests, including weak scaling tests, were performed. The convergence performance of the proposed method is comparable to that of the conventional method. In particular, in elastic-plastic analysis, the proposed method exhibits better convergence performance than the conventional method.

  5. Establishment of Cancer Stem Cell Cultures from Human Conventional Osteosarcoma.

    Science.gov (United States)

    Palmini, Gaia; Zonefrati, Roberto; Mavilia, Carmelo; Aldinucci, Alessandra; Luzi, Ettore; Marini, Francesca; Franchi, Alessandro; Capanna, Rodolfo; Tanini, Annalisa; Brandi, Maria Luisa

    2016-10-14

    The current improvements in therapy against osteosarcoma (OS) have prolonged the lives of cancer patients, but the survival rate of five years remains poor when metastasis has occurred. The Cancer Stem Cell (CSC) theory holds that there is a subset of tumor cells within the tumor that have stem-like characteristics, including the capacity to maintain the tumor and to resist multidrug chemotherapy. Therefore, a better understanding of OS biology and pathogenesis is needed in order to advance the development of targeted therapies to eradicate this particular subset and to reduce morbidity and mortality among patients. Isolating CSCs, establishing cell cultures of CSCs, and studying their biology are important steps to improving our understanding of OS biology and pathogenesis. The establishment of human-derived OS-CSCs from biopsies of OS has been made possible using several methods, including the capacity to create 3-dimensional stem cell cultures under nonadherent conditions. Under these conditions, CSCs are able to create spherical floating colonies formed by daughter stem cells; these colonies are termed "cellular spheres". Here, we describe a method to establish CSC cultures from primary cell cultures of conventional OS obtained from OS biopsies. We clearly describe the several passages required to isolate and characterize CSCs.

  6. Non-invasive or minimally invasive autopsy compared to conventional autopsy of suspected natural deaths in adults: a systematic review.

    Science.gov (United States)

    Blokker, Britt M; Wagensveld, Ivo M; Weustink, Annick C; Oosterhuis, J Wolter; Hunink, M G Myriam

    2016-04-01

    Autopsies are used for healthcare quality control and improving medical knowledge. Because autopsy rates are declining worldwide, various non-invasive or minimally invasive autopsy methods are now being developed. To investigate whether these might replace the invasive autopsies conventionally performed in naturally deceased adults, we systematically reviewed original prospective validation studies. We searched six databases. Two reviewers independently selected articles and extracted data. Methods and patient groups were too heterogeneous for meaningful meta-analysis of outcomes. Sixteen of 1538 articles met our inclusion criteria. Eight studies used a blinded comparison; ten included less than 30 appropriate cases. Thirteen studies used radiological imaging (seven dealt solely with non-invasive procedures), two thoracoscopy and laparoscopy, and one sampling without imaging. Combining CT and MR was the best non-invasive method (agreement for cause of death: 70 %, 95%CI: 62.6; 76.4), but minimally invasive methods surpassed non-invasive methods. The highest sensitivity for cause of death (90.9 %, 95%CI: 74.5; 97.6, suspected duplicates excluded) was achieved in recent studies combining CT, CT-angiography and biopsies. Minimally invasive autopsies including biopsies performed best. To establish a feasible alternative to conventional autopsy and to increase consent to post-mortem investigations, further research in larger study groups is needed. • Health care quality control benefits from clinical feedback provided by (alternative) autopsies. • So far, sixteen studies investigated alternative autopsy methods for naturally deceased adults. • Thirteen studies used radiological imaging modalities, eight tissue biopsies, and three CT-angiography. • Combined CT, CT-angiography and biopsies were most sensitive diagnosing cause of death.

  7. Polyphenol content and antioxidant capacity in organically and conventionally grown vegetables

    Directory of Open Access Journals (Sweden)

    Kevser Unal

    2014-11-01

    Full Text Available Objective: To evaluate the polyphenol content and antioxidant capacity of ethanol extracts of some organically and conventionally grown leafy vegetables. Methods: The ethanol extracts of kailan (Brassica alboglabra, bayam (Amaranthus spp. and sawi (Brassica parachinensis were tested for total phenolic content (TPC, total flavonoid content (TFC, and total anthocyanin content (TAC and the antioxidant capacity of the extracts measured using 2,2-diphenyl-1-picrylhydrazyl assay. Results: In TPC test, sawi extract showed the highest phenolic content while bayam contained the least phenolic content for both organically and conventionally grown types. In TFC test, organically grown sawi extract showed the highest flavonoid content, while organically grown kailan extract showed the least flavonoid content among all types of vegetables. The flavonoid content of the conventionally grown types of vegetable extracts was the highest in kalian and the least in sawi. For 2,2-diphenyl-1-picrylhydrazyl radical scavenging activity, the activity increased with the increasing concentration of each extract. All conventionally grown vegetable extracts showed higher antioxidant activity compared to their organically grown counterparts. Extracts of conventionally grown sawi showed the highest percentage inhibition followed by conventionally grown kailan and organically grown sawi. There were no correlation between TPC, TFC, TAC and IC25 of both organically and conventionally grown vegetables. However, there was a correlation between TAC and IC25 of conventionally grown vegetable extracts. The results showed relatively similar polyphenol content between organically and conventionally grown vegetable extracts. However, the conventionally grown vegetables extracts generally have higher antioxidant activity compared to the organically grown extracts. Conclusions: These results suggested that the different types of agricultural practice had a significant contribution to the

  8. A method for the computation of turbulent polymeric liquids including hydrodynamic interactions and chain entanglements

    Energy Technology Data Exchange (ETDEWEB)

    Kivotides, Demosthenes, E-mail: demosthenes.kivotides@strath.ac.uk

    2017-02-12

    An asymptotically exact method for the direct computation of turbulent polymeric liquids that includes (a) fully resolved, creeping microflow fields due to hydrodynamic interactions between chains, (b) exact account of (subfilter) residual stresses, (c) polymer Brownian motion, and (d) direct calculation of chain entanglements, is formulated. Although developed in the context of polymeric fluids, the method is equally applicable to turbulent colloidal dispersions and aerosols. - Highlights: • An asymptotically exact method for the computation of polymer and colloidal fluids is developed. • The method is valid for all flow inertia and all polymer volume fractions. • The method models entanglements and hydrodynamic interactions between polymer chains.

  9. Comparison of the Debonding Characteristics of Conventional and New Debonding Instrument used for Ceramic, Composite and Metallic Brackets - An Invitro Study.

    Science.gov (United States)

    Choudhary, Garima; Gill, Vikas; Reddy, Y N N; Sanadhya, Sudhanshu; Aapaliya, Pankaj; Sharma, Nidhi

    2014-07-01

    Debonding procedure is time consuming and damaging to the enamel if performed with improper technique. Various debonding methods include: the conventional methods that use pliers or wrenches, an ultrasonic method, electrothermal devices, air pressure impulse devices, diamond burs to grind the brackets off the tooth surface and lasers. Among all these methods, using debonding pliers is most convenient and effective method but has been reported to cause damage to the teeth. Recently, a New Debonding Instrument designed specifically for ceramic and composite brackets has been introduced. As this is a new instrument, little information is available on efficacy of this instrument. The purpose of this study was to evaluate the debonding characteristics of both "the conventional debonding Pliers" and "the New debonding instrument" when removing ceramic, composite and metallic brackets. One Hundred Thirty eight extracted maxillary premolar teeth were collected and divided into two Groups: Group A and Group B (n = 69) respectively. They were further divided into 3 subGroups (n = 23) each according to the types of brackets to be bonded. In subGroups A1 and B1{stainless steel};A2 and B2{ceramic};A3 and B3{composite}adhesive precoated maxillary premolar brackets were used. Among them {ceramic and composite} adhesive pre-coated maxillary premolar brackets were bonded. All the teeth were etched using 37% phosphoric acid for 15 seconds and the brackets were bonded using Transbond XT primer. Brackets were debonded using Conventional Debonding Plier and New Debonding Instrument (Group B). After debonding, the enamel surface of each tooth was examined under stereo microscope (10X magnifications). Amodifiedadhesive remnant index (ARI) was used to quantify the amount of remaining adhesive on each tooth. The observations demonstrate that the results of New Debonding Instrument for debonding of metal, ceramic and composite brackets were statistically significantly different (p = 0

  10. Development of calculation method for one-dimensional kinetic analysis in fission reactors, including feedback effects

    International Nuclear Information System (INIS)

    Paixao, S.B.; Marzo, M.A.S.; Alvim, A.C.M.

    1986-01-01

    The calculation method used in WIGLE code is studied. Because of the non availability of such a praiseworthy solution, expounding the method minutely has been tried. This developed method has been applied for the solution of the one-dimensional, two-group, diffusion equations in slab, axial analysis, including non-boiling heat transfer, accountig for feedback. A steady-state program (CITER-1D), written in FORTRAN 4, has been implemented, providing excellent results, ratifying the developed work quality. (Author) [pt

  11. Interrogating the Conventional Boundaries of Research Methods in Social Sciences: The Role of Visual Representation in Ethnography

    Directory of Open Access Journals (Sweden)

    Nel Glass

    2008-05-01

    Full Text Available The author will propose that the use of performative social science is a means to deliberately interrogate long held conventions of established research. The innovative role of visual art representation in data collection, analysis and public engagement with research will be discussed. Examples will be drawn from two postmodern feminist ethnographic research which investigated academic professional development, resilience, hope and optimism in the UK, US, Australia and New Zealand from 1997-2005. Artwork was initially created as data collection and digitalised as representation to intentionally validate the voices of research participants, the researcher and viewers of the work. The research participants and viewers were given opportunities to actively engage with the visual work. Artwork complimented two additional research methods: critical conversational interviewing and reflective journaling. This paper will address the ways inclusion of art methods contributed and deepened data representation. The role of crafting artwork in the field, the artistic changes that represented the complexity of data analysis and engagement with the work will be explored. It will be argued that the creation and engagement with artwork in research is an empowering and dynamic process for researchers and participants. It is an innovative means of representing intersubjectivity that results in reciprocity. URN: urn:nbn:de:0114-fqs0802509

  12. Retrieval of buried waste using conventional equipment

    International Nuclear Information System (INIS)

    Valentich, D.J.

    1994-01-01

    A field test was conducted to determine the effectiveness of using conventional type construction equipment for the retrieval of buried transuranic (TRU) waste. A cold (nonhazardous and nonradioactive test pit 841 m 3 in volume) was constructed with boxes and drums filled with simulated waste materials, such as metal, plastic, wood, concrete, and sludge. Large objects, including truck beds, vessels, vaults, pipes, and beams were also placed in the pit. These materials were intended to simulate the type of waste found in existing TRU buried waste pits and trenches. A series of commercially available equipment items, such as excavators and tracked loaders outfitted with different end effectors, were used to remove the simulated waste. Work was performed from both the abovegrade and belowgrade positions. During the demonstration, a number of observations, measurements, and analyses were performed to determine which equipment was the most effective in removing the waste. The retrieval rates for the various excavation techniques were recorded. The inherent dust control capabilities of the excavation methods used were also observed

  13. Neural correlates of conventional and harm/welfare-based moral decision-making.

    Science.gov (United States)

    White, Stuart F; Zhao, Hui; Leong, Kelly Kimiko; Smetana, Judith G; Nucci, Larry P; Blair, R James R

    2017-12-01

    The degree to which social norms are processed by a unitary system or dissociable systems remains debated. Much research on children's social-cognitive judgments has supported the distinction between "moral" (harm/welfare-based) and "conventional" norms. However, the extent to which these norms are processed by dissociable neural systems remains unclear. To address this issue, 23 healthy participants were scanned with functional magnetic resonance imaging (fMRI) while they rated the wrongness of harm/welfare-based and conventional transgressions and neutral vignettes. Activation significantly greater than the neutral vignette baseline was observed in regions implicated in decision-making regions including rostral/ventral medial frontal, anterior insula and dorsomedial frontal cortices when evaluating both harm/welfare-based and social-conventional transgressions. Greater activation when rating harm/welfare-based relative to social-conventional transgressions was seen through much of ACC and bilateral inferior frontal gyrus. Greater activation was observed in superior temporal gyrus, bilateral middle temporal gyrus, left PCC, and temporal-parietal junction when rating social-conventional transgressions relative to harm/welfare-based transgressions. These data suggest that decisions regarding the wrongness of actions, irrespective of whether they involve care/harm-based or conventional transgressions, recruit regions generally implicated in affect-based decision-making. However, there is neural differentiation between harm/welfare-based and conventional transgressions. This may reflect the particular importance of processing the intent of transgressors of conventional norms and perhaps the greater emotional content or salience of harm/welfare-based transgressions.

  14. A comparison of piezosurgery with conventional techniques for internal osteotomy.

    Science.gov (United States)

    Koçak, I; Doğan, R; Gökler, O

    2017-06-01

    To compare conventional osteotomy with the piezosurgery medical device, in terms of postoperative edema, ecchymosis, pain, operation time, and mucosal integrity, in rhinoplasty patients. In this prospective study, 49 rhinoplasty patients were randomly divided into two groups according to osteotomy technique used, either conventional osteotomy or piezosurgery. For all patients, the total duration of the operation was recorded, and photographs were taken and scored for ecchymosis and edema on postoperative days 2, 4, and 7. In addition, pain level was evaluated on postoperative day 2, and mucosal integrity was assessed on day 4. All scoring and evaluation was conducted by a physician who was blinded to the osteotomy procedure. In the piezosurgery group, edema scores on postoperative day 2 and ecchymosis scores on postoperative days 2, 4, and 7 were significantly lower than in the conventional osteotomy group (p piezosurgery group than in the conventional osteotomy group (p piezosurgery group. When total operation duration was compared, there was no significant difference between the groups (p > 0.05). Piezosurgery is a safe osteotomy method, with less edema (in the early postoperative period) and ecchymosis compared with conventional osteotomy, as well as less pain, a similar operation duration, and no mucosal damage.

  15. Metal ion implantation: Conventional versus immersion

    International Nuclear Information System (INIS)

    Brown, I.G.; Anders, A.; Anders, S.; Dickinson, M.R.; MacGill, R.A.

    1994-01-01

    Vacuum-arc-produced metal plasma can be used as the ion feedstock material in an ion source for doing conventional metal ion implantation, or as the immersing plasma for doing plasma immersion ion implantation. The basic plasma production method is the same in both cases; it is simple and efficient and can be used with a wide range of metals. Vacuum arc ion sources of different kinds have been developed by the authors and others and their suitability as a metal ion implantation tool has been well established. Metal plasma immersion surface processing is an emerging tool whose characteristics and applications are the subject of present research. There are a number of differences between the two techniques, both in the procedures used and in the modified surfaces created. For example, the condensibility of metal plasma results in thin film formation and subsequent energetic implantation is thus done through the deposited layer; in the usual scenario, this recoil implantation and the intermixing it produces is a feature of metal plasma immersion but not of conventional energetic ion implantation. Metal plasma immersion is more suited (but not limited) to higher doses (>10 17 cm -2 ) and lower energies (E i < tens of keV) than the usual ranges of conventional metal ion implantation. These and other differences provide these vacuum-arc-based surface modification tools with a versatility that enhances the overall technological attractiveness of both

  16. The nuclear liability conventions revised

    International Nuclear Information System (INIS)

    Reyners, P.

    2004-01-01

    The signature on 12 February 2004 of the Protocols amending respectively the 1960 Paris Convention and the 1963 Brussels Supplementary Convention was the second step of the process of modernisation of the international nuclear liability regime after the adoption in September 1997 of a Protocol revising the 1963 Vienna Convention and of a new Convention on Supplementary Compensation for Nuclear Damage. The common objective of the new instruments is to provide more funds to compensate a larger number of potential victims in respect of a broader range of damage. Another goal of the revision exercise was to maintain the compatibility between the Paris and Vienna based systems, a commitment enshrined in the 1988 Joint Protocol, as well as to ascertain that Paris/Brussels countries could also become a Party to the Convention on Supplementary Compensation. However, while generally consistent vis a vis the Joint Protocol, the provisions of the Paris and Vienna Conventions, as revised, differ on some significant aspects. Another remaining issue is whether the improved international nuclear liability regime will succeed in attracting in the future a larger number of countries, particularly outside Europe, and will so become truly universal. Therefore, the need for international co-operation to address these issues, to facilitate the adoption of new implementing legislation and to ensure that this special regime keeps abreast of economic and technological developments, is in no way diminished after the revision of the Conventions.(author)

  17. Limitations of the Conventional Phase Advance Method for Constant Power Operation of the Brushless DC Motor

    International Nuclear Information System (INIS)

    Lawler, J.S.

    2001-01-01

    The brushless dc motor (BDCM) has high-power density and efficiency relative to other motor types. These properties make the BDCM well suited for applications in electric vehicles provided a method can be developed for driving the motor over the 4 to 6:1 constant power speed range (CPSR) required by such applications. The present state of the art for constant power operation of the BDCM is conventional phase advance (CPA)[1]. In this paper, we identify key limitations of CPA. It is shown that the CPA has effective control over the developed power but that the current magnitude is relatively insensitive to power output and is inversely proportional to motor inductance. If the motor inductance is low, then the rms current at rated power and high speed may be several times larger than the current rating. The inductance required to maintain rms current within rating is derived analytically and is found to be large relative to that of BDCM designs using high-strength rare earth magnets. Th us, the CPA requires a BDCM with a large equivalent inductance

  18. Jet-calculus approach including coherence effects

    International Nuclear Information System (INIS)

    Jones, L.M.; Migneron, R.; Narayanan, K.S.S.

    1987-01-01

    We show how integrodifferential equations typical of jet calculus can be combined with an averaging procedure to obtain jet-calculus-based results including the Mueller interference graphs. Results in longitudinal-momentum fraction x for physical quantities are higher at intermediate x and lower at large x than with the conventional ''incoherent'' jet calculus. These results resemble those of Marchesini and Webber, who used a Monte Carlo approach based on the same dynamics

  19. Influence of abutment tooth geometry on the accuracy of conventional and digital methods of obtaining dental impressions.

    Science.gov (United States)

    Carbajal Mejía, Jeison B; Wakabayashi, Kazumichi; Nakamura, Takashi; Yatani, Hirofumi

    2017-09-01

    Direct (intraoral) and indirect (desktop) digital scanning can record abutment tooth preparations despite their geometry. However, little peer-reviewed information is available regarding the influence of abutment tooth geometry on the accuracy of digital methods of obtaining dental impressions. The purpose of this in vitro study was to evaluate the influence of abutment tooth geometry on the accuracy of conventional and digital methods of obtaining dental impressions in terms of trueness and precision. Crown preparations with known total occlusal convergence (TOC) angles (-8, -6, -4, 0, 4, 8, 12, 16, and 22 degrees) were digitally created from a maxillary left central incisor and printed in acrylic resin. Each of these 9 reference models was scanned with a highly accurate reference scanner and saved in standard tessellation language (STL) format. Then, 5 conventional polyvinyl siloxane (PVS) impressions were made from each reference model, which was poured with Type IV dental stone scanned using both the reference scanner (group PVS) and the desktop scanner and exported as STL files. Additionally, direct digital impressions (intraoral group) of the reference models were made, and the STL files were exported. The STL files from the impressions obtained were compared with the original geometry of the reference model (trueness) and within each test group (precision). Data were analyzed using 2-way ANOVA with the post hoc least significant difference test (α=.05). Overall trueness values were 19.1 μm (intraoral scanner group), 23.5 μm (desktop group), and 26.2 μm (PVS group), whereas overall precision values were 11.9 μm (intraoral), 18.0 μm (PVS), and 20.7 μm (desktop). Simple main effects analysis showed that impressions made with the intraoral scanner were significantly more accurate than those of the PVS and desktop groups when the TOC angle was less than 8 degrees (Pimpression and the TOC angle on the precision of single-tooth dental impressions (F=2

  20. Efficacy of adding the Kinesio Taping method to guideline-endorsed conventional physiotherapy in patients with chronic nonspecific low back pain: a randomised controlled trial.

    Science.gov (United States)

    Added, Marco Aurélio Nemitalla; Costa, Leonardo Oliveira Pena; Fukuda, Thiago Yukio; de Freitas, Diego Galace; Salomão, Evelyn Cassia; Monteiro, Renan Lima; Costa, Lucíola da Cunha Menezes

    2013-10-24

    Chronic nonspecific low back pain is a significant health condition with high prevalence worldwide and it is associated with enormous costs to society. Clinical practice guidelines show that many interventions are available to treat patients with chronic low back pain, but the vast majority of these interventions have a modest effect in reducing pain and disability. An intervention that has been widespread in recent years is the use of elastic bandages called Kinesio Taping. Although Kinesio Taping has been used extensively in clinical practice, current evidence does not support the use of this intervention; however these conclusions are based on a small number of underpowered studies. Therefore, questions remain about the effectiveness of the Kinesio Taping method as an additional treatment to interventions, such as conventional physiotherapy, that have already been recommended by the current clinical practice guidelines in robust and high-quality randomised controlled trials. We aim to determine the effectiveness of the addition of the use of Kinesio Taping in patients with chronic nonspecific low back pain who receive guideline-endorsed conventional physiotherapy. One hundred and forty-eight patients will be randomly allocated to receive either conventional physiotherapy, which consists of a combination of manual therapy techniques, general exercises, and specific stabilisation exercises (Guideline-Endorsed Conventional Physiotherapy Group) or to receive conventional physiotherapy with the addition of Kinesio Taping to the lumbar spine (Conventional Physiotherapy plus Kinesio Taping Group) over a period of 5 weeks (10 sessions of treatment). Clinical outcomes (pain intensity, disability and global perceived effect) will be collected at baseline and at 5 weeks, 3 months, and 6 months after randomisation. We will also collect satisfaction with care and adverse effects after treatment. Data will be collected by a blinded assessor. All statistical analysis will be

  1. Flow Rate Measurement in Multiphase Flow Rig: Radiotracer and Conventional

    International Nuclear Information System (INIS)

    Nazrul Hizam Yusoff; Noraishah Othman; Nurliyana Abdullah; Amirul Syafiq Mohd Yunos; Rasif Mohd Zain; Roslan Yahya

    2015-01-01

    Applications of radiotracer technology are prevalent throughout oil refineries worldwide, and this industry is one of the main users and beneficiaries of the technology. Radioactive tracers have been used to a great extent in many applications i.e. flow rate measurement, RTD, plant integrity evaluation and enhancing oil production in oil fields. Chemical and petrochemical plants are generally continuously operating and technically complex where the radiotracer techniques are very competitive and largely applied for troubleshooting inspection and process analysis. Flow rate measurement is a typical application of radiotracers. For flow measurements, tracer data are important, rather than the RTD models. Research is going on in refining the existing methods for single phase flow measurement, and in developing new methods for multiphase flow without sampling. The tracer techniques for single phase flow measurements are recognized as ISO standards. This paper presents technical aspect of laboratory experiments, which have been carried out using Molybdenum-99 - Mo99 (radiotracer) to study and determine the flow rate of liquid in multiphase flow rig. The multiphase flow rig consists of 58.7 m long and 20 cm diameter pipeline that can accommodate about 0.296 m 3 of liquid. Tap water was used as liquid flow in pipeline and conventional flow meters were also installed at the flow rig. The flow rate results; radiotracer and conventional flow meter were compared. The total count method was applied for radiotracer technique and showed the comparable results with conventional flow meter. (author)

  2. Comparison between piezosurgery and conventional osteotomy in cranioplasty with fronto-orbital advancement.

    Science.gov (United States)

    Martini, Markus; Röhrig, Andreas; Reich, Rudolf Hermann; Messing-Jünger, Martina

    2017-03-01

    Cranioplasty of patients with craniosynostosis requires rapid, precise and gentle osteotomy of the skull to avoid complications and benefit the healing process. The aim of this prospective clinical study was to compare two different methods of osteotomy. Piezosurgery and conventional osteotomy were compared using an oscillating saw and high speed drill while performing cranioplasties with fronto-orbital advancement. Thirty-four children who required cranioplasty with fronto-orbital advancement were recruited consecutively. The operations were conducted using piezosurgery or a conventional surgical technique, alternately. Operative time, blood count, CRP and transfusion rate, as well as soft tissue injuries, postoperative edema, pain development and secondary bone healing were investigated. The average age of patients was 9.7 months. The following indications for craniosynostosis were surgically corrected: trigonocephaly (23), anterior plagiocephaly (8), brachycephaly (1), and syndromic craniosynostosis (2). Piezosurgery was utilized in 18 cases. There were no group differences with regard to the incidence of soft tissue injuries (dura, periorbita), pain, swelling, blood loss or bony integration. The duration of osteotomy was significantly longer in the piezosurgery group, leading to slightly increased blood loss, while the postoperative CRP increase was higher using the conventional method. The piezosurgery method is a comparatively safe surgical method for conducting osteotomy during cranioplasty. With regard to soft tissue protection and postoperative clinical course, the same procedural precautions and controls are necessary as those needed for conventional methods. The osteotomy duration is considerably longer using piezosurgery, although it is accompanied by lower initial postoperative CRP values. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  3. Recurrent unexplained palpitations (RUP) study comparison of implantable loop recorder versus conventional diagnostic strategy.

    Science.gov (United States)

    Giada, Franco; Gulizia, Michele; Francese, Maura; Croci, Francesco; Santangelo, Lucio; Santomauro, Maurizio; Occhetta, Eraldo; Menozzi, Carlo; Raviele, Antonio

    2007-05-15

    The aim of the study was to compare the diagnostic yield and the costs of implantable loop recorder (ILR) with those of the conventional strategy in patients with unexplained palpitations. In patients with unexplained palpitations, especially in those with infrequent symptoms, the conventional strategy, including short-term ambulatory electrocardiogram (ECG) monitoring and electrophysiological study, sometimes fails to establish a diagnosis. We studied 50 patients with infrequent (1 min) palpitations. Before enrollment, patients had a negative initial evaluation, including history, physical examination, and ECG. Patients were randomized either to conventional strategy (24-h Holter recording, a 4-week period of ambulatory ECG monitoring with an external recorder, and electrophysiological study) (n = 24) or to ILR implantation with 1-year monitoring (n = 26). Hospital costs of the 2 strategies were calculated. A diagnosis was obtained in 5 patients in the conventional strategy group, and in 19 subjects in the ILR group (21% vs. 73%, p < 0.001). Despite the higher initial cost, the cost per diagnosis in the ILR group was lower than in the conventional strategy group (euro 3,056 +/- euro 363 vs. euro 6,768 +/- euro 6,672, p = 0.012). In subjects without severe heart disease and with infrequent palpitations, ILR is a safe and more cost-effective diagnostic approach than conventional strategy.

  4. The Ultimate Pile Bearing Capacity from Conventional and Spectral Analysis of Surface Wave (SASW) Measurements

    Science.gov (United States)

    Faizah Bawadi, Nor; Anuar, Shamilah; Rahim, Mustaqqim A.; Mansor, A. Faizal

    2018-03-01

    A conventional and seismic method for determining the ultimate pile bearing capacity was proposed and compared. The Spectral Analysis of Surface Wave (SASW) method is one of the non-destructive seismic techniques that do not require drilling and sampling of soils, was used in the determination of shear wave velocity (Vs) and damping (D) profile of soil. The soil strength was found to be directly proportional to the Vs and its value has been successfully applied to obtain shallow bearing capacity empirically. A method is proposed in this study to determine the pile bearing capacity using Vs and D measurements for the design of pile and also as an alternative method to verify the bearing capacity from the other conventional methods of evaluation. The objectives of this study are to determine Vs and D profile through frequency response data from SASW measurements and to compare pile bearing capacities obtained from the method carried out and conventional methods. All SASW test arrays were conducted near the borehole and location of conventional pile load tests. In obtaining skin and end bearing pile resistance, the Hardin and Drnevich equation has been used with reference strains obtained from the method proposed by Abbiss. Back analysis results of pile bearing capacities from SASW were found to be 18981 kN and 4947 kN compared to 18014 kN and 4633 kN of IPLT with differences of 5% and 6% for Damansara and Kuala Lumpur test sites, respectively. The results of this study indicate that the seismic method proposed in this study has the potential to be used in estimating the pile bearing capacity.

  5. Mercury Distribution in the Deûle River (Northern France) Measured by the Diffusive Gradients in Thin Films Technique and Conventional Methods.

    Science.gov (United States)

    Diviš, Pavel; Kadlecová, Milada; Ouddane, Baghdad

    2016-05-01

    The distribution of mercury in surface water and in sediment from Deûle River in Northern France was studied by application of conventional sampling methods and by diffusive gradients in thin films technique (DGT). Concentration of total dissolved mercury in surface water was 20.8 ± 0.8 ng l(-1). The particulate mercury concentration was 6.2 ± 0.6 µg g(-1). The particulate mercury was accumulated in sediment (9.9 ± 2.3 mg kg(-1)), and it was transformed by methylating bacteria to methylmercury, mainly in the first 2-cm layer of the sediment. Total dissolved concentration of mercury in sediment pore water obtained by application of centrifugation extraction was 17.6 ± 4.1 ng l(-1), and it was comparable with total dissolved pore water mercury concentration measured by DGT probe containing Duolite GT-73 resin gel (18.2 ± 4.3 ng l(-1)), taking the sediment heterogeneity and different principles of the applied methods into account. By application of two DGT probes with different resin gels specific for mercury, it was found that approximately 30% of total dissolved mercury in sediment pore water was present in labile forms easy available for biota. The resolution of mercury DGT depth profiles was 0.5 cm, which allows, unlike conventional techniques, to study the connection of the geochemical cycle of mercury with geochemical cycles of iron and manganese.

  6. Beneficial effects of microwave-assisted heating versus conventional heating in noble metal nanoparticle synthesis.

    Science.gov (United States)

    Dahal, Naween; García, Stephany; Zhou, Jiping; Humphrey, Simon M

    2012-11-27

    An extensive comparative study of the effects of microwave versus conventional heating on the nucleation and growth of near-monodisperse Rh, Pd, and Pt nanoparticles has revealed distinct and preferential effects of the microwave heating method. A one-pot synthetic method has been investigated, which combines nucleation and growth in a single reaction via precise control over the precursor addition rate. Using this method, microwave-assisted heating enables the convenient preparation of polymer-capped nanoparticles with improved monodispersity, morphological control, and higher crystallinity, compared with samples heated conventionally under otherwise identical conditions. Extensive studies of Rh nanoparticle formation reveal fundamental differences during the nucleation phase that is directly dependent on the heating method; microwave irradiation was found to provide more uniform seeds for the subsequent growth of larger nanostructures of desired size and surface structure. Nanoparticle growth kinetics are also markedly different under microwave heating. While conventional heating generally yields particles with mixed morphologies, microwave synthesis consistently provides a majority of tetrahedral particles at intermediate sizes (5-7 nm) or larger cubes (8+ nm) upon further growth. High-resolution transmission electron microscopy indicates that Rh seeds and larger nanoparticles obtained from microwave-assisted synthesis are more highly crystalline and faceted versus their conventionally prepared counterparts. Microwave-prepared Rh nanoparticles also show approximately twice the catalytic activity of similar-sized conventionally prepared particles, as demonstrated in the vapor-phase hydrogenation of cyclohexene. Ligand exchange reactions to replace polymer capping agents with molecular stabilizing agents are also easily facilitated under microwave heating, due to the excitation of polar organic moieties; the ligand exchange proceeds with excellent retention of

  7. Complete Tangent Stiffness for eXtended Finite Element Method by including crack growth parameters

    DEFF Research Database (Denmark)

    Mougaard, J.F.; Poulsen, P.N.; Nielsen, L.O.

    2013-01-01

    the crack geometry parameters, such as the crack length and the crack direction directly in the virtual work formulation. For efficiency, it is essential to obtain a complete tangent stiffness. A new method in this work is presented to include an incremental form the crack growth parameters on equal terms......The eXtended Finite Element Method (XFEM) is a useful tool for modeling the growth of discrete cracks in structures made of concrete and other quasi‐brittle and brittle materials. However, in a standard application of XFEM, the tangent stiffness is not complete. This is a result of not including...... with the degrees of freedom in the FEM‐equations. The complete tangential stiffness matrix is based on the virtual work together with the constitutive conditions at the crack tip. Introducing the crack growth parameters as direct unknowns, both equilibrium equations and the crack tip criterion can be handled...

  8. Direct cost of monitoring conventional hemodialysis conducted by nursing professionals

    Directory of Open Access Journals (Sweden)

    Antônio Fernandes Costa Lima

    Full Text Available ABSTRACT Objective: to analyze the mean direct cost of conventional hemodialysis monitored by nursing professionals in three public teaching and research hospitals in the state of São Paulo, Brazil. Method: this was a quantitative, explorative and descriptive investigation, based on a multiple case study approach. The mean direct cost was calculated by multiplying (clocked time spent per procedure by the unit cost of direct labor. Values were calculated in Brazilian real (BRL. Results: Hospital C presented the highest mean direct cost (BRL 184.52, 5.23 times greater than the value for Hospital A (BRL 35.29 and 3.91 times greater than Hospital B (BRL 47.22. Conclusion: the costing method used in this study can be reproduced at other dialysis centers to inform strategies aimed at efficient allocation of necessary human resources to successfully monitor conventional hemodialysis.

  9. Multiple objective optimization of hydro-thermal systems using Ritz's method

    Directory of Open Access Journals (Sweden)

    Arnáu L. Bayón

    1999-01-01

    Full Text Available This paper examines the applicability of the Ritz method to multi-objective optimization of hydro-thermal systems. The algorithm proposed is aimed to minimize an objective functional that incorporates the cost of energy losses, the conventional fuel cost and the production of atmospheric emissions such as NO x and SO 2 caused by the operation of fossil-fueled thermal generation. The formulation includes a general layout of hydro-plants that may form multi-chains of reservoir network. Time-delays are included and the electric network is considered by using the active power balance equation. The volume of water discharge for each hydro-plant is a given constant amount from the optimization interval. The generic minimization algorithm, which is not difficult to construct on the basis of the Ritz method, has certain advantages in comparison with the conventional methods.

  10. Dividend Payout Policy of Conventional Banking and Islamic Banking in Pakistan

    Directory of Open Access Journals (Sweden)

    Farhan Ahmed

    2018-01-01

    Full Text Available This paper investigates the difference between the dividend payout policy of Islamic banks and conventional banks in Pakistan for a period from 2012 to 2016 analyzing the data through regression using Least Square Method (OLS. Specifically, the study aims to study the impact of the profitability, liquidity, revenue growth and financial leverage on the dividend payout policy of the Islamic Banks and conventional banks of Pakistan and how Islamic banks dividend policy differs from conventional banks. This study concludes that the factors like liquidity and financial leverage should be considered and addressed accordingly, because these are key indicators to help policymakers and investors in assessing the performance of the Islamic Banking Industry. DOI: 10.15408/aiq.v10i1.6103

  11. Storage stability of margarines produced from enzymatically interesterified fats compared to those prepared by conventional methods - Chemical properties

    DEFF Research Database (Denmark)

    Zhang, Hong; Jacobsen, Charlotte; Pedersen, Lars Saaby

    2006-01-01

    margarines in a pilot plant. Storage stability studies were carried out at storage temperatures of 5 and 25øC for 12wk. Margarines from the enzymatically interesterified fats were compared to the margarines produced by the conventional methods (chemical interesterification and physical blending......In this study, four margarine hardstocks were produced, two from enzymatically interesterified fats at 80 and 100% conversion, one from chemically randomized fat and one from physically mixed fat. These four hardstocks, blended with 50% sunflower oil, were mainly used for the production of table...... interesterified fat had higher PV in weeks4, 8 and10 than the margarines produced from the enzymatically interesterified fats and the physically blended fat. These differences were not caused by different contents of tocopherols in the hardstocks. The differences between the processes for chemical and enzymatic...

  12. A systematic review and meta-analysis of Harmonic technology compared with conventional techniques in mastectomy and breast-conserving surgery with lymphadenectomy for breast cancer.

    Science.gov (United States)

    Cheng, Hang; Clymer, Jeffrey W; Ferko, Nicole C; Patel, Leena; Soleas, Ireena M; Cameron, Chris G; Hinoul, Piet

    2016-01-01

    Mastectomy and breast-conserving surgery (BCS) are important treatment options for breast cancer patients. A previous meta-analysis demonstrated that the risk of certain complications can be reduced with the Harmonic technology compared with conventional methods in mastectomy. However, the meta-analysis did not include studies of BCS patients and focused on a subset of surgical complications. The objective of this study was to compare Harmonic technology and conventional techniques for a range of clinical outcomes and complications in both mastectomy and BCS patients, including axillary lymph node dissection. A comprehensive literature search was performed for randomized controlled trials comparing Harmonic technology and conventional methods in breast cancer surgery. Outcome measures included blood loss, drainage volume, total complications, seroma, necrosis, wound infections, ecchymosis, hematoma, hospital length of stay, and operating time. Risk of bias was analyzed for all studies. Meta-analysis was performed using random-effects models for mean differences of continuous variables and a fixed-effects model for risk ratios of dichotomous variables. Twelve studies met the inclusion criteria. Across surgery types, compared to conventional techniques, Harmonic technology reduced total complications by 52% (P=0.002), seroma by 46% (Pmastectomy patients with lymph node dissection, Harmonic technology showed significant reductions in complications in the BCS study subgroup. In this meta-analysis of both mastectomy and BCS procedures, the use of Harmonic technology reduced the risk of most complications by about half across breast cancer surgery patients. These benefits may be due to superior hemostatic capabilities of Harmonic technology and better dissection, particularly lymph node dissection. Reduction in complications and other resource outcomes may engender lower downstream health care costs.

  13. Randomized controlled pilot study to compare Homeopathy and Conventional therapy in Acute Otitis Media.

    Science.gov (United States)

    Sinha, M N; Siddiqui, V A; Nayak, C; Singh, Vikram; Dixit, Rupali; Dewan, Deepti; Mishra, Alok

    2012-01-01

    To compare the effectiveness of Homeopathy and Conventional therapy in Acute Otitis Media (AOM). A randomized placebo-controlled parallel group pilot study of homeopathic vs conventional treatment for AOM was conducted in Jaipur, India. Patients were randomized by a computer generated random number list to receive either individualized homeopathic medicines in fifty millesimal (LM) potencies, or conventional treatment including analgesics, antipyretics and anti-inflammatory drugs. Patients who did not improve were prescribed antibiotics at the 3rd day. Outcomes were assessed by the Acute Otitis Media-Severity of Symptoms (AOM-SOS) Scale and Tympanic Membrane Examination over 21 days. 81 patients were included, 80 completed follow-up: 41 for conventional and 40 for homeopathic treatment. In the Conventional group, all 40 (100%) patients were cured, in the Homeopathy group, 38 (95%) patients were cured while 02 (5%) patients were lost to the last two follow-up. By the 3rd day of treatment, 4 patients were cured in Homeopathy group but in Conventional group only one patient was cured. In the Conventional group antibiotics were prescribed in 39 (97.5%), no antibiotics were required in the Homeopathy group. 85% of patients were prescribed six homeopathic medicines. Individualized homeopathy is an effective conventional treatment in AOM, there were no significant differences between groups in the main outcome. Symptomatic improvement was quicker in the Homeopathy group, and there was a large difference in antibiotic requirements, favouring homeopathy. Further work on a larger scale should be conducted. Copyright © 2011 The Faculty of Homeopathy. Published by Elsevier Ltd. All rights reserved.

  14. Comparative Effectiveness of Homoeopathic vs. Conventional Therapy in Usual Care of Atopic Eczema in Children: Long-Term Medical and Economic Outcomes

    Science.gov (United States)

    Roll, Stephanie; Reinhold, Thomas; Pach, Daniel; Brinkhaus, Benno; Icke, Katja; Staab, Doris; Jäckel, Tanja; Wegscheider, Karl; Willich, Stefan N.; Witt, Claudia M.

    2013-01-01

    Background One in five children visiting a homeopathic physician suffers from atopic eczema. Objectives We aimed to examine the long-term effectiveness, safety and costs of homoeopathic vs. conventional treatment in usual medical care of children with atopic eczema. Methods In this prospective multi-centre comparative observational non-randomized rater-blinded study, 135 children (48 homoeopathy, 87 conventional) with mild to moderate atopic eczema were included by their respective physicians. Depending on the specialisation of the physician, the primary treatment was either standard conventional treatment or individualized homeopathy as delivered in routine medical care. The main outcome was the SCORAD (SCORing Atopic Dermatitis) at 36 months by a blinded rater. Further outcomes included quality of life, conventional medicine consumption, safety and disease related costs at six, 12 and 36 months after baseline. A multilevel ANCOVA was used, with physician as random effect and the following fixed effects: age, gender, baseline value, severity score, social class and parents’ expectation. Results The adjusted mean SCORAD showed no significant differences between the groups at 36 months (13.7 95% CI [7.9–19.5] vs. 14.9 [10.4–19.4], p = 0.741). The SCORAD response rates at 36 months were similar in both groups (33% response: homoeopathic 63.9% vs. conventional 64.5%, p = 0.94; 50% response: 52.0% vs. 52.3%, p = 0.974). Total costs were higher in the homoeopathic versus the conventional group (months 31–36 200.54 Euro [132.33–268.76] vs. 68.86 Euro [9.13–128.58], p = 0.005). Conclusions Taking patient preferences into account, while being unable to rule out residual confounding, in this long-term observational study, the effects of homoeopathic treatment were not superior to conventional treatment for children with mild to moderate atopic eczema, but involved higher costs. PMID:23383019

  15. Full arch scans: conventional versus digital impressions--an in-vitro study.

    Science.gov (United States)

    Ender, A; Mehl, A

    2011-01-01

    The digital intraoral impression has become a central part of the CAD/CAM technique. The objective of the present study was to compare the accuracy (trueness and precision) of digital impressions of the full arch with that of conventional impressions on the in-vitro model. For this purpose, a master model was acquired with a new reference scanning process, the measuring trueness of which was +/- 4.1 microm and the precision +/- 2.5 microm. On the one hand, conventional impressions and then plaster models (n = 5) were produced from this master model, and on the other hand, digital impressions were made with the Cerec AC Bluecam and the Lava COS system (each n = 5). The plaster models were also scanned with the reference scanner. The available data records were superimposed and the differences determined. The deviation from the master model defines the trueness of the impression method. The deviations of the models among one another demonstrate the precision of the method. The trueness of the impressions was 55 +/- 21.8 microm in the conventional impression group, for digital impressions with Cerec Bluecam it was 49 +/- 14.2 microm and for digital impressions with Lava COS 40.3 +/- 14.1 microm. The precision was 61.3 +/- 17.9 microm for conventional impression with Impregum, 30.9 +/- 7.1 microm for digital impression with the Cerec Bluecam and 60.1 +/- 31.3 microm for digital impression with Lava COS. These in-vitro results show that accuracy of the digital impression is similar to that of the conventional impression. These results will have to be confirmed in further clinical studies.

  16. Method for assessment of stormwater treatment facilities - Synthetic road runoff addition including micro-pollutants and tracer.

    Science.gov (United States)

    Cederkvist, Karin; Jensen, Marina B; Holm, Peter E

    2017-08-01

    Stormwater treatment facilities (STFs) are becoming increasingly widespread but knowledge on their performance is limited. This is due to difficulties in obtaining representative samples during storm events and documenting removal of the broad range of contaminants found in stormwater runoff. This paper presents a method to evaluate STFs by addition of synthetic runoff with representative concentrations of contaminant species, including the use of tracer for correction of removal rates for losses not caused by the STF. A list of organic and inorganic contaminant species, including trace elements representative of runoff from roads is suggested, as well as relevant concentration ranges. The method was used for adding contaminants to three different STFs including a curbstone extension with filter soil, a dual porosity filter, and six different permeable pavements. Evaluation of the method showed that it is possible to add a well-defined mixture of contaminants despite different field conditions by having a flexibly system, mixing different stock-solutions on site, and use bromide tracer for correction of outlet concentrations. Bromide recovery ranged from only 12% in one of the permeable pavements to 97% in the dual porosity filter, stressing the importance of including a conservative tracer for correction of contaminant retention values. The method is considered useful in future treatment performance testing of STFs. The observed performance of the STFs is presented in coming papers. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Comparison Of INAA Methods (Long Conventional, Cyclic And Pseudo-Cyclic) For The Determination Of Se In Biological Samples

    International Nuclear Information System (INIS)

    Sarheel, A.

    2004-01-01

    Selenium content in serum blood, sample were received from international comparison programme (SABC) has been determined by Cyclic irradiation, pseudo-cyclic irradiation and long irradiation conventional Instrumental neutron activation analysis through the 162 keV gamma ray of the 77m Se nuclide for both cyclic and pseudo-cyclic and 264 keV gamma ray of 75 Se nuclide for conventional (long irradiation). The CINAA involve irradiation of samples for 20 s, decay for 15 s and counting for 20 s, samples recycling four times to improve the precision. The PCINAA involve irradiation of samples for 20 s, decay for 20 s and counting for 30s, samples recycling four times day by day. The Conventional (long irradiation) involve irradiation of samples for 20 hr (1 week), decay for 4 weeks and counting for 20 hr. The accuracy has been evaluated by analyzing the certified reference materials. (Author)

  18. The nuclear safety convention. Results for Argentine as contracting party

    International Nuclear Information System (INIS)

    Caruso, Gustavo

    2002-01-01

    A powerful mechanism for increasing safety worldwide is through the development and adoption of legally binding Safety Conventions. Since 1986 four Conventions were ratified in the areas of Nuclear, Radiation and Waste Safety. The Nuclear Safety Convention establishes an international co-operation mechanism to maintain safety nuclear installations, focused on: to achieve and maintain a high level of nuclear safety worldwide through the enhancement of national measures and international co-operation including, where appropriate, safety-related technical co-operation; to establish and maintain effective defences in nuclear installations against potential radiological hazards in order to protect individuals, society and the environment from harmful effects of ionizing radiation from such installations and to prevent accidents with radiological consequences and to mitigate such consequences should they occur. Each contracting party shall take, within the framework of its national law, the legislative, regulatory and administrative measures and other steps necessary for implementing its obligations under this Convention. Moreover, each contracting parties shall submit for review prior to each review meeting, a National Report on the measures it has taken to implement each of the obligations of the Convention. The contracting parties concluded that the review process had proven to be of great value to their national nuclear safety programmes. (author)

  19. Gonad Shielding for Patients Undergoing Conventional Radiological Examinations: Is There Cause for Concern?

    OpenAIRE

    Karami; Zabihzadeh; Gholami

    2016-01-01

    Background Gonad shielding is one of the fundamental methods by which to protect reproductive organs in patients undergoing conventional radiological examinations. A lack of or inadequate shielding of the gonads may increase the exposure of these organs and result in malignancies future generations. Objectives The aim of this study is to investigate the prevalence of gonad shielding in patients undergoing conventional radiological...

  20. Convention on Nuclear Safety. Second National Report, October 2001

    International Nuclear Information System (INIS)

    2001-01-01

    The present document is the second Spanish national report prepared in order to comply with the obligations deriving from the convention on Nuclear Safety, made in Vienna on 20th September 1994. This convention was signed by Spain on 15th October 1994 and ratified by way of an instrument issued by the Ministry of Foreign Affairs, signed by H. M. the King on 19th June 1995. The convention, which entered into force on 24th October 1996, following ratification by a minimum number of countries, as set out in articles 20, 21 and 22 includes 51 countries and Euratom, in addition to Spain. The first review meeting, organised in accordance with chapter 3 of the Convention, was held in vienna in April 1999. Spain was represented by the CSN, the State organisation solely responsible for nuclear safety, both for the drawing up of the national report and for participation in the meeting held between the parties. In accordance with article 21, the second review meeting has been scheduled for April 2002, also in Vienna. At the review meeting, the countries party to the Convention review the national reports required by article 5, Spain submitted its first national report in September 1998. The present document is an update of that first report, and is to be submitted by 15th October 2001, as agreed on during the first review meeting. This report will be reviewed by the interested countries, which will forward their comments and questions. In April 2002, the Spanish report and the questions received will be subjected to the review process contemplated by the convention, along with the reports submitted by the other countries

  1. Dumping convention

    International Nuclear Information System (INIS)

    Roche, P.

    1992-01-01

    Sea dumping of radioactive waste has, since 1983, been precluded under a moratorium established by the London Dumping Convention. Pressure from the nuclear industry to allow ocean dumping of nuclear waste is reported in this article. (author)

  2. Comparison of several plant nutrient elements in conventionally and ...

    African Journals Online (AJOL)

    Organic citrus production has been increasing recently in Turkey. In this study, we compared several nutri-elements concentrations of organically (ORG) and conventionally (CON) grown citrus orchards in the Mediterranean region of Turkey. The samples included Satsuma mandarins (Citrus unshiu L.) and Washington ...

  3. Comparison of several plant nutrient elements in conventionally and ...

    African Journals Online (AJOL)

    STORAGESEVER

    2009-04-20

    Apr 20, 2009 ... Organic citrus production has been increasing recently in Turkey. In this study, we compared several nutri-elements concentrations of organically (ORG) and conventionally (CON) grown citrus orchards in the Mediterranean region of Turkey. The samples included Satsuma mandarins (Citrus unshiu L.) and.

  4. Scientific and technical development and the chemical weapon convention

    International Nuclear Information System (INIS)

    Siddiqui, P.H.

    2008-01-01

    The Chemical Weapons Convention (CWC) was drafted with the recognition that it is impossible to envision every way in which toxic chemicals might be used for aggressive purposes. As terrorist organizations and rogue states replace the major powers as the most likely candidates to employ chemical weapons, the agents of choice may differ from those developed for battlefield use. Twenty- first century chemical warfare may target civilians or agricultural production, and clandestine production-facilities may manufacture toxic agents from chemical precursors, not monitored under the CWC control regime. The effects (on CWC implementation) of changing industrial technologies, including ongoing developments in chemical process technology, dual-use industrial chemicals, and rapid methods for discovering biologically active chemicals, are considerable Also considered is how commercial technologies could be misused for the development of novel chemical weapons, and how such abuses might be detected and monitored. (author)

  5. Understanding the conventional arms trade

    Science.gov (United States)

    Stohl, Rachel

    2017-11-01

    The global conventional arms trade is worth tens of billions of dollars every year and is engaged in by every country in the world. Yet, it is often difficult to control the legal trade in conventional arms and there is a thriving illicit market, willing to arm unscrupulous regimes and nefarious non-state actors. This chapter examines the international conventional arms trade, the range of tools that have been used to control it, and challenges to these international regimes.

  6. One-year results of total arterial revascularization vs. conventional coronary surgery: CARRPO trial

    DEFF Research Database (Denmark)

    Damgaard, Sune; Wetterslev, Jørn; Lund, Jens T

    2009-01-01

    +/- 18% in the conventional group (P = 0.52). In 72% of TAR patients and 67% of the conventional group, all grafts were patent (P = 0.45). Multiple imputation of missing angiographic data did not influence on results. Within 1 year, 37 (23%) TAR patients and 43 (25%) conventional group patients suffered...... cardiac events (HR 1.09, 95% CI 0.70-1.69, P = 0.70). One patient (0.6%) in the TAR group and two (1.2%) in the conventional group died (P = 1.00). CONCLUSION: Within 1 year post-operatively, TAR seems at least as safe and effective as CR. Prolonged follow-up will reveal whether this is sustained......AIMS: To investigate clinical and angiographic outcomes after coronary surgery using total arterial revascularization (TAR). METHODS AND RESULTS: We randomized 331 patients with multivessel or isolated left main disease to TAR [internal thoracic (ITA) and radial arteries] vs. conventional...

  7. Method and apparatus for controlling a powertrain system including a multi-mode transmission

    Science.gov (United States)

    Hessell, Steven M.; Morris, Robert L.; McGrogan, Sean W.; Heap, Anthony H.; Mendoza, Gil J.

    2015-09-08

    A powertrain including an engine and torque machines is configured to transfer torque through a multi-mode transmission to an output member. A method for controlling the powertrain includes employing a closed-loop speed control system to control torque commands for the torque machines in response to a desired input speed. Upon approaching a power limit of a power storage device transferring power to the torque machines, power limited torque commands are determined for the torque machines in response to the power limit and the closed-loop speed control system is employed to determine an engine torque command in response to the desired input speed and the power limited torque commands for the torque machines.

  8. Reliability and limitation of various diagnostic methods including nuclear medicine in myocardial disease

    International Nuclear Information System (INIS)

    Tokuyasu, Yoshiki; Kusakabe, Kiyoko; Yamazaki, Toshio

    1981-01-01

    Electrocardiography (ECG), echocardiography, nuclear method, cardiac catheterization, left ventriculography and endomyocardial biopsy (biopsy) were performed in 40 cases of cardiomyopathy (CM), 9 of endocardial fibroelastosis and 19 of specific heart muscle disease, and the usefulness and limitation of each method was comparatively estimated. In CM, various methods including biopsy were performed. The 40 patients were classified into 3 groups, i.e., hypertrophic (17), dilated (20) and non-hypertrophic.non-dilated (3) on the basis of left ventricular ejection fraction and hypertrophy of the ventricular wall. The hypertrophic group was divided into 4 subgroups: 9 septal, 4 apical, 2 posterior and 2 anterior. The nuclear study is useful in assessing the site of the abnormal ventricular thickening, perfusion defect and ventricular function. Echocardiography is most useful in detecting asymmetric septal hypertrophy. The biopsy gives the sole diagnostic clue, especially in non-hypertrophic.non-dilated cardiomyopathy. ECG is useful in all cases but correlation with the site of disproportional hypertrophy was not obtained. (J.P.N.)

  9. Development of measure methods of radon in indoor air

    International Nuclear Information System (INIS)

    Yaginuma, L.T.; Pela, C.A.; Navas, E.A.; Ghilardi, A.J.P.

    1992-01-01

    The development of some conventional measuring methods, aiming obtain an estimation of radon concentration in air, mainly in indoor air is described, including the charcoal absorption collector, Lucas cell and thermoluminescent dosemeters. (C.G.C)

  10. Digital subtraction ventriculography for assessment of global and regional leftventricular parameters in comparison to conventional contrast ventriculography

    International Nuclear Information System (INIS)

    Eichstaedt, H.; Langer, M.; Felix, R.

    1984-01-01

    Since May 1982 we studied more than 100 patients with heart diseases by means of digital angiography, out of them 46 patients with a history of transmural myocardial infarction were selected. Urografin 76, 30 ml, was administered at a flow rate of 18 ml/s by means of a catheter in the superior vena cava during digital subtraction ventriculography. Results were compared with conventional contrast ventriculograms. The correlation coefficient was r=0.93 (p 0.001) for determination of ejection fraction with both methods. The data in individual cases suggest that DSV is more sensitive than conventional contrast ventriculography in determination of severely reduced ejection fractions. The methods are practically identical in qualitative evaluation of disorders of regional wall motion in the anterolateral region, while DSV is more sensitive than conventional ventriculography in evaluating the apical region. Sensitivity was 85.7% when the two methods were compared in evaluation of the inferior region of the left ventricle. Both methods are identical in demonstration of severely deformed ventricles. Digital subtraction ventriculography may replace conventional contrast ventriculography in some of situations discussed above. (orig.)

  11. Comparison of the CoaguChek XS handheld coagulation analyzer and conventional laboratory methods measuring international normalised ratio (INR) values during the time to therapeutic range after mechanical valve surgery.

    Science.gov (United States)

    Bardakci, Hasmet; Altıntaş, Garip; Çiçek, Omer Faruk; Kervan, Umit; Yilmaz, Sevinc; Kaplan, Sadi; Birincioglu, Cemal Levent

    2013-05-01

    To compare the international normalised ratio (INR) value of patients evaluated using the CoaguChek XS versus conventional laboratory methods, in the period after open-heart surgery for mechanical valve replacement until a therapeutic range is achieved using vitamin K antagonists (VKA) together with low molecular weight heparin (LMWH). One hundred and five patients undergoing open-heart surgery for mechanical valve replacement were enrolled. Blood samples were collected from patients before surgery, and on the second and fifth postoperative days, simultaneously for both the point of care device and conventional laboratory techniques. Patients were administered VKA together with LMWH at therapeutic doses (enoxaparin 100 IU/kg twice daily) subcutaneously, until an effective range was achieved on approximately the fifth day after surgery. The mean INR values using the CoaguChek XS preoperatively and on the second and fifth days postoperatively were 1.20 (SD ± 0.09), 1.82 (SD ± 0.45), and 2.55 (SD ± 0.55), respectively. Corresponding results obtained using conventional laboratory techniques were 1.18 (SD ± 0.1), 1.81 (SD ± 0.43), and 2.51 (SD ± 0.58). The correlation coefficient was r = 0.77 preoperatively, r = 0.981 on postoperative day 2, and r = 0.983 on postoperative day 5. Results using the CoaguChek XS Handheld Coagulation Analyzer correlated strongly with conventional laboratory methods, in the bridging period between open-heart surgery for mechanical valve replacement and the achievement of a therapeutic range on warfarin and LMWH. © 2013 Wiley Periodicals, Inc.

  12. Patient satisfaction and side effects in primary care: An observational study comparing homeopathy and conventional medicine

    Directory of Open Access Journals (Sweden)

    Thurneysen André

    2008-09-01

    Full Text Available Abstract Background This study is part of a nationwide evaluation of complementary medicine in Switzerland (Programme Evaluation of Complementary Medicine PEK and was funded by the Swiss Federal Office of Public Health. The main objective of this study is to investigate patient satisfaction and perception of side effects in homeopathy compared with conventional care in a primary care setting. Methods We examined data from two cross-sectional studies conducted in 2002–2003. The first study was a physician questionnaire assessing structural characteristics of practices. The second study was conducted on four given days during a 12-month period in 2002/2003 using a physician and patient questionnaire at consultation and a patient questionnaire mailed to the patient one month later (including Europep questionnaire. The participating physicians were all trained and licensed in conventional medicine. An additional qualification was required for medical doctors providing homeopathy (membership in the Swiss association of homeopathic physicians SVHA. Results A total of 6778 adult patients received the questionnaire and 3126 responded (46.1%. Statistically significant differences were found with respect to health status (higher percentage of chronic and severe conditions in the homeopathic group, perception of side effects (higher percentage of reported side effects in the conventional group and patient satisfaction (higher percentage of satisfied patients in the homeopathic group. Conclusion Overall patient satisfaction was significantly higher in homeopathic than in conventional care. Homeopathic treatments were perceived as a low-risk therapy with two to three times fewer side effects than conventional care

  13. Comparison of the method of diffusive gels in thin films with conventional extraction techniques for evaluating zinc accumulation in plants and isopods

    Energy Technology Data Exchange (ETDEWEB)

    Koster, Marijke [National Institute of Public Health and the Environment, Laboratory for Ecological Risk Assessment, P.O. Box 1, 3720 BA Bilthoven (Netherlands); Open University Netherlands, Heerlen (Netherlands); Reijnders, Lucas [Open University Netherlands, Heerlen (Netherlands); Oost, Nathalie R. van [National Institute of Public Health and the Environment, Laboratory for Ecological Risk Assessment, P.O. Box 1, 3720 BA Bilthoven (Netherlands); Peijnenburg, Willie J.G.M. [National Institute of Public Health and the Environment, Laboratory for Ecological Risk Assessment, P.O. Box 1, 3720 BA Bilthoven (Netherlands)]. E-mail: wjgm.peijnenburg@rivm.nl

    2005-01-01

    The measurement of diffusive gels in thin films (DGT) has recently been developed to assess metal bioavailability in soils. The DGT-method is based on diffusion in a porous matrix. To test the predictive capabilities of the method with regard to metal bioavailability, a study was set up with 28 soils having a variety of textures and amounts of zinc salts added. Correlation and regression analyses were performed to compare DGT-extracted zinc levels to zinc concentrations obtained by extraction with 0.01 M CaCl{sub 2} and 0.43 M HNO{sub 3}, digestion with aqua regia and the zinc concentration in pore water. The amount of zinc extracted with CaCl{sub 2} correlated well with DGT-extracted zinc levels in all soils spiked with different amounts of ZnCl{sub 2}. A similar correlation was not found for zinc concentrations in soil samples collected in the field. Experiments were performed to compare zinc content in organisms and in soils. The organisms tested were plants (grass, lettuce and lupine) and the hard bodied soil dwelling isopod Oniscus asellus. Good correlations were found between zinc accumulation in grass and lettuce and the C{sub E} (effective concentration) measured by a DGT-device, CaCl{sub 2} extracted zinc and the zinc content in the pore water of all soils. The correlation with C{sub E} was not significant for lupine, neither for spiked soils, nor for field soils (p {<=} 0.001). Zinc levels in the isopods were not significantly related to any set of zinc measurements. From a synthesis of all results obtained it is concluded that the DGT-methodology does not have an additional value in predicting bioavailability of zinc in terrestrial ecosystems as compared to conventional extraction methods. - Capsule: The newly developed method of diffusive gels in Thin films (DGT) does not have an added value over conventional extraction techniques in predicting zinc uptake by plants and isopods.

  14. Comparison of the method of diffusive gels in thin films with conventional extraction techniques for evaluating zinc accumulation in plants and isopods

    International Nuclear Information System (INIS)

    Koster, Marijke; Reijnders, Lucas; Oost, Nathalie R. van; Peijnenburg, Willie J.G.M.

    2005-01-01

    The measurement of diffusive gels in thin films (DGT) has recently been developed to assess metal bioavailability in soils. The DGT-method is based on diffusion in a porous matrix. To test the predictive capabilities of the method with regard to metal bioavailability, a study was set up with 28 soils having a variety of textures and amounts of zinc salts added. Correlation and regression analyses were performed to compare DGT-extracted zinc levels to zinc concentrations obtained by extraction with 0.01 M CaCl 2 and 0.43 M HNO 3 , digestion with aqua regia and the zinc concentration in pore water. The amount of zinc extracted with CaCl 2 correlated well with DGT-extracted zinc levels in all soils spiked with different amounts of ZnCl 2 . A similar correlation was not found for zinc concentrations in soil samples collected in the field. Experiments were performed to compare zinc content in organisms and in soils. The organisms tested were plants (grass, lettuce and lupine) and the hard bodied soil dwelling isopod Oniscus asellus. Good correlations were found between zinc accumulation in grass and lettuce and the C E (effective concentration) measured by a DGT-device, CaCl 2 extracted zinc and the zinc content in the pore water of all soils. The correlation with C E was not significant for lupine, neither for spiked soils, nor for field soils (p ≤ 0.001). Zinc levels in the isopods were not significantly related to any set of zinc measurements. From a synthesis of all results obtained it is concluded that the DGT-methodology does not have an additional value in predicting bioavailability of zinc in terrestrial ecosystems as compared to conventional extraction methods. - Capsule: The newly developed method of diffusive gels in Thin films (DGT) does not have an added value over conventional extraction techniques in predicting zinc uptake by plants and isopods

  15. Study of the magnetic microstructure of high-coercivity sintered SmCo5 permanent magnets with the conventional Bitter pattern technique and the colloid-SEM method

    International Nuclear Information System (INIS)

    Szmaja, Witold

    2007-01-01

    The magnetic microstructure of high-coercivity sintered SmCo 5 permanent magnets was studied with the conventional Bitter pattern technique, and also for the first time with the colloid-scanning electron microscopy (colloid-SEM) method. Both techniques were supported by digital image acquisition, enhancement and analysis. Thanks to this, it was possible to obtain high-contrast and clear images of the magnetic microstructure and to analyze them in detail, and consequently also to achieve improvements over earlier results. In the thermally demagnetized state the grains were composed of magnetic domains. On the surface perpendicular to the alignment axis, the main domains forming a maze pattern and surface reverse spikes were observed. Investigations on the surface parallel to the alignment axis, especially by the colloid-SEM technique, provided a detailed insight into the orientation of grains. The alignment of grains was good, but certainly not perfect; there were also strongly misaligned grains, although generally very rare. In most cases the domain structures within grains were independent of their neighbors, but in some cases (not so rare) the domain walls were observed to continue through the grain boundaries, indicating significant magnetostatic interaction between neighboring grains. Studies of the behavior of the magnetic microstructure under the influence of an external magnetic field, performed for the first time on the surface parallel to the alignment axis (with the conventional Bitter pattern method), showed that the domain walls move easily within the grains and that the magnetization reversal mechanism is mainly related to the nucleation and growth of reverse domains, i.e. that sintered SmCo 5 magnets are nucleation-dominated systems. Groupwise magnetization reversal of adjacent magnetically coupled grains was observed, an unfavorable effect for high-coercivity magnets. Images obtained by the colloid-SEM technique and the conventional Bitter pattern

  16. Comparison of Conventional and ANN Models for River Flow Forecasting

    Science.gov (United States)

    Jain, A.; Ganti, R.

    2011-12-01

    Hydrological models are useful in many water resources applications such as flood control, irrigation and drainage, hydro power generation, water supply, erosion and sediment control, etc. Estimates of runoff are needed in many water resources planning, design development, operation and maintenance activities. River flow is generally estimated using time series or rainfall-runoff models. Recently, soft artificial intelligence tools such as Artificial Neural Networks (ANNs) have become popular for research purposes but have not been extensively adopted in operational hydrological forecasts. There is a strong need to develop ANN models based on real catchment data and compare them with the conventional models. In this paper, a comparative study has been carried out for river flow forecasting using the conventional and ANN models. Among the conventional models, multiple linear, and non linear regression, and time series models of auto regressive (AR) type have been developed. Feed forward neural network model structure trained using the back propagation algorithm, a gradient search method, was adopted. The daily river flow data derived from Godavari Basin @ Polavaram, Andhra Pradesh, India have been employed to develop all the models included here. Two inputs, flows at two past time steps, (Q(t-1) and Q(t-2)) were selected using partial auto correlation analysis for forecasting flow at time t, Q(t). A wide range of error statistics have been used to evaluate the performance of all the models developed in this study. It has been found that the regression and AR models performed comparably, and the ANN model performed the best amongst all the models investigated in this study. It is concluded that ANN model should be adopted in real catchments for hydrological modeling and forecasting.

  17. Selections from the ABC 2012 Annual Convention, Honolulu, Hawaii

    Science.gov (United States)

    Whalen, D. Joel

    2013-01-01

    The 13 Favorite Assignments featured here were presented at the 2012 Association for Business Communication (ABC) Annual Convention, Honolulu, Hawaii. A variety of learning objectives are featured, including the following: enhancing resume's visual impact, interpersonal skills, social media, team building, web design, community service projects,…

  18. Comparing Amazon's Mechanical Turk Platform to Conventional Data Collection Methods in the Health and Medical Research Literature.

    Science.gov (United States)

    Mortensen, Karoline; Hughes, Taylor L

    2018-04-01

    The goal of this article is to conduct an assessment of the peer-reviewed primary literature with study objectives to analyze Amazon.com 's Mechanical Turk (MTurk) as a research tool in a health services research and medical context. Searches of Google Scholar and PubMed databases were conducted in February 2017. We screened article titles and abstracts to identify relevant articles that compare data from MTurk samples in a health and medical context to another sample, expert opinion, or other gold standard. Full-text manuscript reviews were conducted for the 35 articles that met the study criteria. The vast majority of the studies supported the use of MTurk for a variety of academic purposes. The literature overwhelmingly concludes that MTurk is an efficient, reliable, cost-effective tool for generating sample responses that are largely comparable to those collected via more conventional means. Caveats include survey responses may not be generalizable to the US population.

  19. 'Augmented reality' in conventional simulation by projection of 3-D structures into 2-D images. A comparison with virtual methods

    Energy Technology Data Exchange (ETDEWEB)

    Deutschmann, H.; Nairz, O.; Zehentmayr, F.; Fastner, G.; Sedlmayer, F. [Univ. Clinic for Radiotherapy and Radio-Oncology, Salzburg (Austria); radART - Inst. for research and development on Advanced Radiation Technologies at the Paracelsus Medical Univ., Salzburg (Austria); Steininger, P. [radART - Inst. for research and development on Advanced Radiation Technologies at the Paracelsus Medical Univ., Salzburg (Austria); Dept. of Medical Computer Science and Technology, Univ. for Health Sciences, Hall i. T. (Austria); Kopp, P.; Merz, F.; Wurstbauer, K.; Kranzinger, M.; Kametriser, G.; Kopp, M. [Univ. Clinic for Radiotherapy and Radio-Oncology, Salzburg (Austria)

    2008-02-15

    Background and purpose: in this study, a new method is introduced, which allows the overlay of three-dimensional structures, that have been delineated on transverse slices, onto the fluoroscopy from conventional simulators in real time. Patients and methods: setup deviations between volumetric imaging and simulation were visualized, measured and corrected for 701 patient isocenters. Results: comparing the accuracy to mere virtual simulation lacking additional X-ray imaging, a clear benefit of the new method could be shown. On average, virtual prostate simulations had to be corrected by 0.48 cm (standard deviation [SD] 0.38), and those of the breast by 0.67 cm (SD 0.66). Conclusion: the presented method provides an easy way to determine entity-specific safety margins related to patient setup errors upon registration of bony anatomy (prostate 0.9 cm for 90% of cases, breast 1.3 cm). The important role of planar X-ray imaging was clearly demonstrated. The innovation can also be applied to adaptive image-guided radiotherapy (IGRT) protocols. (orig.)

  20. Quality characteristics of battered and fried chicken: comparison of pressure frying and conventional frying.

    Science.gov (United States)

    Das, Rashmi; Pawar, Deepthi P; Modi, Vinod Kumar

    2013-04-01

    The marinated and battered chicken leg meat and breast meat were pressure fried and their physico-chemical qualities were compared to the conventional fried product (open pan deep fat frying). Shrinkage due to frying process was significantly lesser in case of pressure fried leg meat (PLM) and breast meat (PBM) as compared to products prepared by conventional frying leg meat (CLM) and breast meat (CBM). Also, juiciness of pressure fried chicken products was superior (p ≤ 0.05) than fried products obtained by the conventional method. PLM and PBM had lower fat content (p ≤ 0.05) compared to conventionally fried CLM and CBM. Lipid oxidation was higher (p ≤ 0.05) in conventional frying as compared to pressure frying. Irrespective of the type of chicken meat, conventionally fried meat required higher shear force as compared to pressure fried products. Salmonella, Staphylococcus aureus, Shigella and E. coli were not detected. The study indicates the usefulness and superiority of pressure frying in comparison to conventional deep fat frying.

  1. Comparison between conventional and ultrasonic preparation of beef tallow biodiesel

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Leonardo S.G. [Instituto de Quimica - Universidade Federal da Bahia, Campus Universitario de Ondina, 40.170-280 - Salvador, Bahia (Brazil); Assis, Julio C.R.; Santos, Iran T.V.; Guimaraes, Paulo R.B.; Pontes, Luiz A.M. [Universidade Salvador - UNIFACS - Departamento de Engenharia e Arquitetura, - Av. Cardeal da Silva 132, 40.220-141 - Salvador, Bahia (Brazil); Mendonca, Daniel R. [Escola Politecnica - Universidade Federal da Bahia, Av. Aristides Novis 2, 40.210-630, Salvador, Bahia (Brazil); Teixeira, Josanaide S.R. [Instituto Federal de Educacao Ciencia e Tecnologica da Bahia - IFBAHIA - Rua Emidio de Morais S/N, 40.625-650, Salvador - BA (Brazil)

    2009-09-15

    Tallow is biodiesel feedstock that, due to its highly centralized generation in slaughter/processing facilities and historically low prices, may have energetic, environmental, and economic advantages that could be exploited. Transesterification of fatty acids by means of ultrasonic energy has been used for biodiesel production from different vegetable oils. However, application of ultrasonic irradiation for biodiesel production from beef tallow has received little attention. In this work, the transesterification of beef tallow with methanol was performed in the presence of potassium hydroxide as a catalyst using ultrasound irradiation (400 W, 24 kHz). The reaction time, conversion and biodiesel quality were compared with that seen in conventional transesterification. The results indicated that the reaction conversion and biodiesel quality were similar; however, the use of ultrasonic irradiation decreased the reaction time, showing that this method may be a promising alternative to the conventional method. (author)

  2. Comparison between conventional and ultrasonic preparation of beef tallow biodiesel

    International Nuclear Information System (INIS)

    Teixeira, Leonardo S.G.; Assis, Julio C.R.; Santos, Iran T.V.; Guimaraes, Paulo R.B.; Pontes, Luiz A.M.; Mendonca, Daniel R.; Teixeira, Josanaide S.R.

    2009-01-01

    Tallow is biodiesel feedstock that, due to its highly centralized generation in slaughter/processing facilities and historically low prices, may have energetic, environmental, and economic advantages that could be exploited. Transesterification of fatty acids by means of ultrasonic energy has been used for biodiesel production from different vegetable oils. However, application of ultrasonic irradiation for biodiesel production from beef tallow has received little attention. In this work, the transesterification of beef tallow with methanol was performed in the presence of potassium hydroxide as a catalyst using ultrasound irradiation (400 W, 24 kHz). The reaction time, conversion and biodiesel quality were compared with that seen in conventional transesterification. The results indicated that the reaction conversion and biodiesel quality were similar; however, the use of ultrasonic irradiation decreased the reaction time, showing that this method may be a promising alternative to the conventional method. (author)

  3. Assessment for the management of NORM wastes in conventional hazardous and nonhazardous waste landfills

    Energy Technology Data Exchange (ETDEWEB)

    Mora, Juan C., E-mail: jc.mora@ciemat.es [Unit for Radiation Protection of the Public and the Environment (PRPYMA), CIEMAT, Avda. Complutense, 40, 28040 Madrid (Spain); Energy Engineering Department, Power Engineering, Nuclear Area, ETSII, UNED (Spain); Baeza, Antonio [LARUEX, Dpt. Applied Physics, Faculty of Veterinary Science, University of Extremadura, Avda. Universidad, s/n, 10071 Cáceres (Spain); Robles, Beatriz [Unit for Radiation Protection of the Public and the Environment (PRPYMA), CIEMAT, Avda. Complutense, 40, 28040 Madrid (Spain); Sanz, Javier [Energy Engineering Department, Power Engineering, Nuclear Area, ETSII, UNED (Spain)

    2016-06-05

    Highlights: • Before 2010 NORM waste is managed as non-radioactive, disposed in landfills. • After 2010 radiological impact of the management of NORM wastes must be assessed. • Quantities that can be disposed in hazardous or non-hazardous landfills are given. • Uncertainty analysis is included to provide consistency to the calculations. - Abstract: Naturally Occurring Radioactive Materials (NORM) wastes are generated in huge quantities in several industries and their management has been carried out under considerations of industrial non-radioactive wastes, before the concern on the radioactivity content was included in the legislation. Therefore these wastes were conditioned using conventional methods and the waste disposals were designed to isolate toxic elements from the environment for long periods of time. Spanish regulation for these conventional toxic waste disposals includes conditions that assure adequate isolation to minimize the impact of the wastes to the environment in present and future conditions. After 1996 the radiological impact of the management of NORM wastes is considered and all the aspects related with natural radiations and the radiological control regarding the management of residues from NORM industries were developed in the new regulation. One option to be assessed is the disposal of NORM wastes in hazardous and non-hazardous waste disposals, as was done before this new regulation. This work analyses the management of NORM wastes in these landfills to derive the masses that can be disposed without considerable radiological impact. Generic dose assessments were carried out under highly conservative hypothesis and a discussion on the uncertainty and variability sources was included to provide consistency to the calculations.

  4. Assessment for the management of NORM wastes in conventional hazardous and nonhazardous waste landfills

    International Nuclear Information System (INIS)

    Mora, Juan C.; Baeza, Antonio; Robles, Beatriz; Sanz, Javier

    2016-01-01

    Highlights: • Before 2010 NORM waste is managed as non-radioactive, disposed in landfills. • After 2010 radiological impact of the management of NORM wastes must be assessed. • Quantities that can be disposed in hazardous or non-hazardous landfills are given. • Uncertainty analysis is included to provide consistency to the calculations. - Abstract: Naturally Occurring Radioactive Materials (NORM) wastes are generated in huge quantities in several industries and their management has been carried out under considerations of industrial non-radioactive wastes, before the concern on the radioactivity content was included in the legislation. Therefore these wastes were conditioned using conventional methods and the waste disposals were designed to isolate toxic elements from the environment for long periods of time. Spanish regulation for these conventional toxic waste disposals includes conditions that assure adequate isolation to minimize the impact of the wastes to the environment in present and future conditions. After 1996 the radiological impact of the management of NORM wastes is considered and all the aspects related with natural radiations and the radiological control regarding the management of residues from NORM industries were developed in the new regulation. One option to be assessed is the disposal of NORM wastes in hazardous and non-hazardous waste disposals, as was done before this new regulation. This work analyses the management of NORM wastes in these landfills to derive the masses that can be disposed without considerable radiological impact. Generic dose assessments were carried out under highly conservative hypothesis and a discussion on the uncertainty and variability sources was included to provide consistency to the calculations.

  5. Methods of ammonia removal in anaerobic digestion: a review.

    Science.gov (United States)

    Krakat, Niclas; Demirel, Burak; Anjum, Reshma; Dietz, Donna

    2017-10-01

    The anaerobic digestion of substrates with high ammonia content has always been a bottleneck in the methanisation process of biomasses. Since microbial communities in anaerobic digesters are sensitive to free ammonia at certain conditions, the digestion of nitrogen-rich substrates such as livestock wastes may result in inhibition/toxicity eventually leading to process failures, unless appropriate engineering precautions are taken. There are many different options reported in literature to remove ammonia from anaerobic digesters to achieve a safe and stable process so that along with high methane yields, a good quality of effluents can also be obtained. Conventional techniques to remove ammonia include physical/chemical methods, immobilization and adaptation of microorganisms, while novel methods include ultrasonication, microwave, hollow fiber membranes and microbial fuel cell applications. This paper discusses conventional and novel methods of ammonia removal from anaerobic digesters using nitrogen-rich substrates, with particular focus on recent literature available about this topic.

  6. Comparison of root canal lathing measurement by conventional and digital radiology

    International Nuclear Information System (INIS)

    Mitrova, N.; Slavik, J.; Cecetkova, A.; Jenca, A.; Hanusinova, V.; Ondrasovicova, J.

    2006-01-01

    A correct working length is a critical factor within the endodontic treatment. The length of the root canal can be measured by different methods. The aim of this study was to compare methods used for measuring the length of root canals using conventional and digital radiology. The measurement was provided in both - in vitro and in vivo conditions. (authors)

  7. Comparison Between Physics and Conventional Forceps in Simple Dental Extraction.

    Science.gov (United States)

    El-Kenawy, Mohamed H; Ahmed, Wael Mohamed Said

    2015-12-01

    Atraumatic dental extraction preserves bone, gingival architecture, and allows for the option of future or immediate dental implant placement. A number of tools and techniques have been proposed for minimally invasive tooth removal such as physics forceps. The biomechanical design of physics forceps decreases the incidence of root fracture, and maintains the buccal bone plate, which is essential for the proper healing of an immediately placed dental implant. This study was conducted to evaluate the efficacy of physics forceps versus conventional forceps in simple dental extraction. 200 adult patients seeking simple dental extraction were selected from the Outpatient Clinic in the Oral and Maxillofacial Surgery Department, Faculty of Dentistry, Mansoura University, Egypt. The selected patients were randomly allocated into two groups: group I: included 100 patients, in this group extraction was done using physics forceps, and group II: included 100 patients, in this group extraction was done using conventional forceps. In physics forceps group: crown fracture occurred in three cases (3 %), buccal bone fracture occurred in three cases (3 %), and root fracture occurred in 14 roots (8.5 %), while in conventional forceps group: crown fracture occurred in 10 cases (10 %), buccal bone fracture occurred in seven cases (7 %), and root fracture occurred in 27 roots (16.6 %). Physics forceps are innovative extraction instruments. By using them, it is possible to perform difficult extractions, with predictable results, and without need to reflect a flap. Using physics forceps decreases the incidence of crown, root, and buccal bone plate fractures, in comparison to the conventional forceps.

  8. Wreck removal and the Nairobi Convention - a movement towards a unified framework?

    Directory of Open Access Journals (Sweden)

    Jhonnie Mikael Kern

    2016-02-01

    Full Text Available The Nairobi International Convention on the Removal of Wrecks came into force on the 14 of April 2015 and provides a framework for wreck removal. Three central questions arise when dealing with shipwrecks; Who is responsible? What measures can and are to be taken based on such a responsibility? And lastly; how can the responsibility be enforced? The Nairobi Convention on the Removal of Wrecks addresses these questions. The registered owner of a ship bears strict liability according to the convention but can be exonerated by certain limited defenses. Measures that are to be taken include locating, marking and subsequently removing the wreck. The onus to remove the wreck is on the registered owner, but there are also options available for the State affected by the wreck should the registered owner not cooperate or be unable to contact. Finally the convention strives to ensure enforceability by compulsory insurance for ships, wherever registered, with a gross tonnage of 300 tons and above calling any port or offshore facility in a State Party. The convention also enables an Affected State to claim the insurer directly. This article will analyze the convention by the use of the convention text, its preparatory works and legal writing. The article suggests that even though the convention provides a unified framework for wreck removal, it has inclusions that may actually inhibit harmonization. The convention is also in part unclear and ambiguous. Despite this the article concludes in the convention being a natural step forward in unifying the regulation of wrecks and providing a platform to deal with wreck removal in the future.

  9. A randomized trial of early versus delayed mediastinal drain removal after cardiac surgery using silastic and conventional tubes

    Science.gov (United States)

    Moss, Emmanuel; Miller, Corey S.; Jensen, Henrik; Basmadjian, Arsène; Bouchard, Denis; Carrier, Michel; Perrault, Louis P.; Cartier, Raymond; Pellerin, Michel; Demers, Philippe

    2013-01-01

    OBJECTIVES Mediastinal drainage following cardiac surgery with traditional large-bore plastic tubes can be painful and cumbersome. This study was designed to determine whether prolonged drainage (5 days) with a silastic tube decreased the incidence of significant pericardial effusion and tamponade following aortic or valvular surgery. METHODS One hundred and fifty patients undergoing valvular or aortic surgery in a tertiary cardiac surgery institution were randomized to receive a conventional mediastinal tube plus a silastic Blake drain (n = 75), or two conventional tubes (n = 75). Conventional drains were removed on postoperative day (POD) 1, while Blake drains were removed on POD 5. The primary end-point was the combined incidence of significant pericardial effusion (≥15 mm) or tamponade through POD 5. Secondary end-points included total mediastinal drainage, postoperative atrial fibrillation (AF) and pain. RESULTS Analysis was performed for 67 patients in the Blake group and 73 in the conventional group. There was no difference between the two groups in the combined end-point of significant effusion or tamponade (7.4 vs 8.3%, P = 0.74), or in the incidence of AF (47 vs 46%, P = 0.89). Mean 24-h drainage was greater in the Blake group than in the conventional group (749 ± 444 ml vs 645 ± 618 ml, P tubes is safe and does not increase postoperative pain. There was no difference between the Blake and conventional drains with regard to significant pericardial effusion or tamponade in this cohort; however, this conclusion is limited by the low overall incidence of the primary outcome in this cohort. PMID:23575759

  10. Game-based e-learning is more effective than a conventional instructional method: a randomized controlled trial with third-year medical students.

    Science.gov (United States)

    Boeker, Martin; Andel, Peter; Vach, Werner; Frankenschmidt, Alexander

    2013-01-01

    When compared with more traditional instructional methods, Game-based e-learning (GbEl) promises a higher motivation of learners by presenting contents in an interactive, rule-based and competitive way. Most recent systematic reviews and meta-analysis of studies on Game-based learning and GbEl in the medical professions have shown limited effects of these instructional methods. To compare the effectiveness on the learning outcome of a Game-based e-learning (GbEl) instruction with a conventional script-based instruction in the teaching of phase contrast microscopy urinalysis under routine training conditions of undergraduate medical students. A randomized controlled trial was conducted with 145 medical students in their third year of training in the Department of Urology at the University Medical Center Freiburg, Germany. 82 subjects where allocated for training with an educational adventure-game (GbEl group) and 69 subjects for conventional training with a written script-based approach (script group). Learning outcome was measured with a 34 item single choice test. Students' attitudes were collected by a questionnaire regarding fun with the training, motivation to continue the training and self-assessment of acquired knowledge. The students in the GbEl group achieved significantly better results in the cognitive knowledge test than the students in the script group: the mean score was 28.6 for the GbEl group and 26.0 for the script group of a total of 34.0 points with a Cohen's d effect size of 0.71 (ITT analysis). Attitudes towards the recent learning experience were significantly more positive with GbEl. Students reported to have more fun while learning with the game when compared to the script-based approach. Game-based e-learning is more effective than a script-based approach for the training of urinalysis in regard to cognitive learning outcome and has a high positive motivational impact on learning. Game-based e-learning can be used as an effective teaching

  11. Effects Of Using Non-Conventional Feedstuffs On The Productivity ...

    African Journals Online (AJOL)

    This study examines effects of privately producing layers mash by including such non-conventional feedstuff as cassava, brewers dried grain, etc on the productivity, cost and profit of poultry (eggs) farms. Primary data was collected from three categories of farms – 12” convcentional feedstuff users“ (CFU), ...

  12. Methods of forming aluminum oxynitride-comprising bodies, including methods of forming a sheet of transparent armor

    Science.gov (United States)

    Chu, Henry Shiu-Hung [Idaho Falls, ID; Lillo, Thomas Martin [Idaho Falls, ID

    2008-12-02

    The invention includes methods of forming an aluminum oxynitride-comprising body. For example, a mixture is formed which comprises A:B:C in a respective molar ratio in the range of 9:3.6-6.2:0.1-1.1, where "A" is Al.sub.2O.sub.3, "B" is AlN, and "C" is a total of one or more of B.sub.2O.sub.3, SiO.sub.2, Si--Al--O--N, and TiO.sub.2. The mixture is sintered at a temperature of at least 1,600.degree. C. at a pressure of no greater than 500 psia effective to form an aluminum oxynitride-comprising body which is at least internally transparent and has at least 99% maximum theoretical density.

  13. Evolutionary Games and Social Conventions

    DEFF Research Database (Denmark)

    Hansen, Pelle Guldborg

    2007-01-01

    -defined metaphors of individual learning and social imitation processes, from which a revised theory of convention may be erected (see Sugden 2004, Binmore 1993 and Young 1998). This paper makes a general argument in support of the evolutionary turn in the theory of convention by a progressive exposition of its...... in Aumann (1976) and which, together with the assumptions of perfect rationality, came to be defining of classical game theory. However, classical game theory is currently undergoing severe crisis as a tool for exploring social phenomena; a crisis emerging from the problem of equilibrium selection around......Some thirty years ago Lewis published his Convention: A Philosophical Study (Lewis, 2002). This laid the foundation for a game-theoretic approach to social conventions, but became more famously known for its seminal analysis of common knowledge; the concept receiving its canonical analysis...

  14. Effect of high-intensity pulsed electric fields processing and conventional heat treatment on orange-carrot juice carotenoids.

    Science.gov (United States)

    Torregrosa, Francisco; Cortés, Clara; Esteve, María J; Frígola, Ana

    2005-11-30

    Liquid chromatography (LC) was the method of choice for quantification of carotenoids (including geometrical isomers) to evaluate the effects of high-intensity pulsed electric field (HIPEF), a nonthermal preservation method, with different parameters (electric field intensities and treatment times), on an orange-carrot juice mixture (80:20, v/v). In parallel, a conventional heat treatment (98 degrees C, 21 s) was applied to the juice. HIPEF processing generally caused a significant increase in the concentrations of the carotenoids identified as treatment time increased. HIPEF treatment at 25 and 30 kV/cm provided a vitamin A concentration higher than that found in the pasteurized juice.

  15. Ultrasound-assisted phase-transfer catalysis method in an aqueous medium to promote the Knoevenagel reaction: advantages over the conventional and microwave-assisted solvent-free/catalyst-free method.

    Science.gov (United States)

    De-la-Torre, Pedro; Osorio, Edison; Alzate-Morales, Jans H; Caballero, Julio; Trilleras, Jorge; Astudillo-Saavedra, Luis; Brito, Iván; Cárdenas, Alejandro; Quiroga, Jairo; Gutiérrez, Margarita

    2014-09-01

    Given the broad spectrum of uses of acrylonitrile derivatives as fluorescent probes, AChE inhibitors, and others, it is necessary to find easy, efficient and simple methods to synthesize and diversify these compounds. We report the results of a comparative study of the effects of three techniques on the reactions between heterocyclic aldehydes and 2-(benzo[d]thiazol-2-yl)acetonitrile: stirring; ultrasound coupled to PTC conditions (US-PTC); and MW irradiation (MWI) under solvent and catalyst-free conditions. The effects of conditions on reaction parameters were evaluated and compared in terms of reaction time, yield, purity and outcomes. The US-PTC method is more efficient than the MWI and conventional methods. The reaction times were considerably shorter, with high yields (>90%) and good levels of purity. In addition, X-ray diffraction analysis and quantum mechanical calculations, at the level of density functional theory (DFT), ratify obtaining acrylonitrile isomers with E configurations. The crystal structure of 3c is stabilized by weak C-Ho⋯N intermolecular interactions (Ho⋯NC=2.45 Å, Co⋯NC=3.348(3) Å, Ho⋯NC=162°), forming centrosymmetric ring R2(2) (20) along the crystallographic a axis. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Applications of the rotating orientation XRD method to oriented materials

    International Nuclear Information System (INIS)

    Guo Zhenqi; Li Fei; Jin Li; Bai Yu

    2009-01-01

    The rotating orientation x-ray diffraction (RO-XRD) method, based on conventional XRD instruments by a modification of the sample stage, was introduced to investigate the orientation-related issues of such materials. In this paper, we show its applications including the determination of single crystal orientation, assistance in crystal cutting and evaluation of crystal quality. The interpretation of scanning patterns by RO-XRD on polycrystals with large grains, bulk material with several grains and oriented thin film is also presented. These results will hopefully expand the applications of the RO-XRD method and also benefit the conventional XRD techniques. (fast track communication)

  17. A philosophical and critical analysis of the European convention of bioethics.

    Science.gov (United States)

    Hottois, G

    2000-04-01

    The Convention for the Protection of Human Rights and Dignity of the Human Being with Regard to the Application of Biology and Medicine is now one of the most important bioethics texts from the point of view of international policy and law. It is the result of five years of discussions and negotiations between the different instances of the Council of Europe. In this article I analyze several problems. First, there are problems of articulation between the Convention and the joint Explanatory Report. The oriented exegesis of the Explanatory Report raises suspicion about the Convention, which appears as a smooth facade for an instrument actually serving ideological positions many people do not share. Second, there are problems of formulation within the Convention. These are mainly problems with articles that state prohibitions without any distinction, relativization, contextualization or sense of evolution. Finally, there are problems of substance, leading to the conclusion that the Convention is not a good illustration of the human rights philosophical tradition in the name of which it has been proclaimed. This tradition is the one of Enlightenment. And when Kant summarizes the motto of Enlightenment, the injunction is "Sapere Aude!": "Dare to know!" It is difficult to hear such a message through the Convention, and the Explanatory Report includes too many passages and sentences that mean the opposite.

  18. Preliminary report: prescription of prism-glasses by the Measurement and Correction Method of H.-J. Haase or by conventional orthoptic examination: a multicenter, randomized, double-blind, cross-over study

    NARCIS (Netherlands)

    Simonsz, H. J.; van Els, J.; Ruijter, J. M.; Bakker, D.; Spekreijse, H.

    2001-01-01

    In a multicenter, randomized, double-blind, cross-over study in the Netherlands, the effectiveness of (prism-)glasses prescribed by the Measurement and Correction Method of H.-J. Haase (MKH) was compared to that of glasses prescribed by conventional orthoptic examination. Nine pairs of

  19. Engine including hydraulically actuated valvetrain and method of valve overlap control

    Science.gov (United States)

    Cowgill, Joel [White Lake, MI

    2012-05-08

    An exhaust valve control method may include displacing an exhaust valve in communication with the combustion chamber of an engine to an open position using a hydraulic exhaust valve actuation system and returning the exhaust valve to a closed position using the hydraulic exhaust valve actuation assembly. During closing, the exhaust valve may be displaced for a first duration from the open position to an intermediate closing position at a first velocity by operating the hydraulic exhaust valve actuation assembly in a first mode. The exhaust valve may be displaced for a second duration greater than the first duration from the intermediate closing position to a fully closed position at a second velocity at least eighty percent less than the first velocity by operating the hydraulic exhaust valve actuation assembly in a second mode.

  20. Treatment of children with Helicobacter pylori infection and malabsorption syndromes with probiotics: Comparison with conventional methods

    International Nuclear Information System (INIS)

    Ghoos, Y.; Brunser, O.; Lawson, F.; Muzeke, A.; Ndjaye, M.F.

    2000-01-01

    It is stated that in developing countries a high rate of Helicobacter pylori infection among newborns and young children occurs. It is further assumed that this incidence may lead to inhibition of defense mechanism (inhibition of acid secretion) against bacteria, per orally ingested. This may result in excessive colonisation of the small intestine by bacteria. This situation may become a major cause for chronic malnutrition and diarrhoea syndrome with failure to thrive. This project aims at determining the occurrence of Helicobacter pylori infection in children at young age. It is aimed also at tracing the relationship between the Helicobacter pylori infection and the state of undernourishment. Finally it is aimed at comparing the usefulness of pre-/probiotics as anti-infection treatment. The methods used to demonstrate above mentioned parameters are based on stable isotopes, 13 CO 2 and H 2 breath tests mainly. To assess nutritional status and progress in growth conventional anthropometric techniques will be used, complementary to the results obtained by stable isotopes. It is put forward that the use of pre-/probiotics, instead of antibiotics, will suppress upper gastrointestinal infection and restore the intestinal cell capacity to assimilate all food ingredients. (author)

  1. Treatment of children with Helicobacter pylori infection and malabsorption syndromes with probiotics: Comparison with conventional methods

    Energy Technology Data Exchange (ETDEWEB)

    Ghoos, Y [UZ Gasthuisberg, Gastrointestinal Pathophysiology, Leuven (Belgium); Brunser, O [Institute of Nutrition and Food Technology, Santiago (Chile); Lawson, F [Clinique Padre Pio, Cotonou (Benin); Muzeke, A [Faculte de Medicine, University of Kinshasa, Kinshasa (Congo); Ndjaye, M F [Cercle Senegalais Gastroenterologie, Dakar (Senegal)

    2000-07-01

    It is stated that in developing countries a high rate of Helicobacter pylori infection among newborns and young children occurs. It is further assumed that this incidence may lead to inhibition of defense mechanism (inhibition of acid secretion) against bacteria, per orally ingested. This may result in excessive colonisation of the small intestine by bacteria. This situation may become a major cause for chronic malnutrition and diarrhoea syndrome with failure to thrive. This project aims at determining the occurrence of Helicobacter pylori infection in children at young age. It is aimed also at tracing the relationship between the Helicobacter pylori infection and the state of undernourishment. Finally it is aimed at comparing the usefulness of pre-/probiotics as anti-infection treatment. The methods used to demonstrate above mentioned parameters are based on stable isotopes, {sup 13}CO{sub 2} and H{sub 2} breath tests mainly. To assess nutritional status and progress in growth conventional anthropometric techniques will be used, complementary to the results obtained by stable isotopes. It is put forward that the use of pre-/probiotics, instead of antibiotics, will suppress upper gastrointestinal infection and restore the intestinal cell capacity to assimilate all food ingredients. (author)

  2. Comparing risk in conventional and organic dairy farming in the Netherlands: an empirical analysis.

    Science.gov (United States)

    Berentsen, P B M; Kovacs, K; van Asseldonk, M A P M

    2012-07-01

    This study was undertaken to contribute to the understanding of why most dairy farmers do not convert to organic farming. Therefore, the objective of this research was to assess and compare risks for conventional and organic farming in the Netherlands with respect to gross margin and the underlying price and production variables. To investigate the risk factors a farm accountancy database was used containing panel data from both conventional and organic representative Dutch dairy farms (2001-2007). Variables with regard to price and production risk were identified using a gross margin analysis scheme. Price risk variables were milk price and concentrate price. The main production risk variables were milk yield per cow, roughage yield per hectare, and veterinary costs per cow. To assess risk, an error component implicit detrending method was applied and the resulting detrended standard deviations were compared between conventional and organic farms. Results indicate that the risk included in the gross margin per cow is significantly higher in organic farming. This is caused by both higher price and production risks. Price risks are significantly higher in organic farming for both milk price and concentrate price. With regard to production risk, only milk yield per cow poses a significantly higher risk in organic farming. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  3. Dural ectasia and conventional radiography in the Marfan lumbosacral spine

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, N U [Dept. of Orthopaedic Surgery, Johns Hopkins Univ. School of Medicine, Baltimore (United States); Johns Hopkins Outpatient Center, Dept. of Orthopaedic Surgery, Baltimore, MD (United States); Nallamshetty, L; Ahn, U M; Buchowski, J M; Kebaish, K M; Sponseller, P D [Dept. of Orthopaedic Surgery, Johns Hopkins Univ. School of Medicine, Baltimore (United States); Rose, P S [Dept. of Orthopaedic Surgery, Johns Hopkins Univ. School of Medicine, Baltimore (United States); National Human Genome Research Institute, National Institutes of Health, Bethesda, MD (United States); Garrett, E S [Dept. of Oncology, Division of Biostatistics, Johns Hopkins University School of Medicine, Baltimore (United States)

    2001-06-01

    Objective. To determine how well conventional radiographic findings can predict the presence of dural ectasia in Marfan patients.Design and patients. Twelve Marfan patients without dural ectasia and 21 Marfan patients with dural ectasia were included in the study. Five radiographic measurements were made of the lumbosacral spine: interpediculate distance, scalloping value, sagittal canal diameter, vertebral body width, and transverse process width.Results. The following measurements were significantly larger in patients with dural ectasia: interpediculate distances at L3-L4 levels (P<0.03); scalloping values at the L1 and L5 levels (P<0.05); sagittal diameters of the vertebral canal at L5-S1 (P<0.03); transverse process to width ratios at L2 (P<0.03). Criteria were developed for diagnosis of dural ectasia in Marfan patients. These included presence of one of the following: interpediculate distance at L4 >38.0 mm, sagittal diameter at S1 >18.0 mm, or scalloping value at L5 >5.5 mm.Conclusion. Dural ectasia in Marfan syndrome is commonly associated with several osseous changes that are observable on conventional radiographs of the lumbosacral spine. Conventional radiography can detect dural ectasia in patients with Marfan syndrome with a very high specificity (91.7%) but a low sensitivity (57.1%). (orig.)

  4. Non-Conventional Yeast Strains Increase the Aroma Complexity of Bread

    Science.gov (United States)

    Rezaei, Mohammad Naser; Steensels, Jan; Courtin, Christophe M.; Verstrepen, Kevin J.

    2016-01-01

    Saccharomyces cerevisiae is routinely used yeast in food fermentations because it combines several key traits, including fermentation efficiency and production of desirable flavors. However, the dominance of S. cerevisiae in industrial fermentations limits the diversity in the aroma profiles of the end products. Hence, there is a growing interest in non-conventional yeast strains that can help generate the diversity and complexity desired in today’s diversified and consumer-driven markets. Here, we selected a set of non-conventional yeast strains to examine their potential for bread fermentation. Here, we tested ten non-conventional yeasts for bread fermentation, including two Saccharomyces species that are not currently used in bread making and 8 non-Saccharomyces strains. The results show that Torulaspora delbrueckii and Saccharomyces bayanus combine satisfactory dough fermentation with an interesting flavor profile. Sensory analysis and HS-SPME-GC-MS analysis confirmed that these strains produce aroma profiles that are very different from that produced by a commercial bakery strain. Moreover, bread produced with these yeasts was preferred by a majority of a trained sensory panel. These results demonstrate the potential of T. delbrueckii and S. bayanus as alternative yeasts for bread dough leavening, and provide a general experimental framework for the evaluation of more yeasts and bacteria. PMID:27776154

  5. Non-Conventional Yeast Strains Increase the Aroma Complexity of Bread.

    Science.gov (United States)

    Aslankoohi, Elham; Herrera-Malaver, Beatriz; Rezaei, Mohammad Naser; Steensels, Jan; Courtin, Christophe M; Verstrepen, Kevin J

    2016-01-01

    Saccharomyces cerevisiae is routinely used yeast in food fermentations because it combines several key traits, including fermentation efficiency and production of desirable flavors. However, the dominance of S. cerevisiae in industrial fermentations limits the diversity in the aroma profiles of the end products. Hence, there is a growing interest in non-conventional yeast strains that can help generate the diversity and complexity desired in today's diversified and consumer-driven markets. Here, we selected a set of non-conventional yeast strains to examine their potential for bread fermentation. Here, we tested ten non-conventional yeasts for bread fermentation, including two Saccharomyces species that are not currently used in bread making and 8 non-Saccharomyces strains. The results show that Torulaspora delbrueckii and Saccharomyces bayanus combine satisfactory dough fermentation with an interesting flavor profile. Sensory analysis and HS-SPME-GC-MS analysis confirmed that these strains produce aroma profiles that are very different from that produced by a commercial bakery strain. Moreover, bread produced with these yeasts was preferred by a majority of a trained sensory panel. These results demonstrate the potential of T. delbrueckii and S. bayanus as alternative yeasts for bread dough leavening, and provide a general experimental framework for the evaluation of more yeasts and bacteria.

  6. Non-Conventional Yeast Strains Increase the Aroma Complexity of Bread.

    Directory of Open Access Journals (Sweden)

    Elham Aslankoohi

    Full Text Available Saccharomyces cerevisiae is routinely used yeast in food fermentations because it combines several key traits, including fermentation efficiency and production of desirable flavors. However, the dominance of S. cerevisiae in industrial fermentations limits the diversity in the aroma profiles of the end products. Hence, there is a growing interest in non-conventional yeast strains that can help generate the diversity and complexity desired in today's diversified and consumer-driven markets. Here, we selected a set of non-conventional yeast strains to examine their potential for bread fermentation. Here, we tested ten non-conventional yeasts for bread fermentation, including two Saccharomyces species that are not currently used in bread making and 8 non-Saccharomyces strains. The results show that Torulaspora delbrueckii and Saccharomyces bayanus combine satisfactory dough fermentation with an interesting flavor profile. Sensory analysis and HS-SPME-GC-MS analysis confirmed that these strains produce aroma profiles that are very different from that produced by a commercial bakery strain. Moreover, bread produced with these yeasts was preferred by a majority of a trained sensory panel. These results demonstrate the potential of T. delbrueckii and S. bayanus as alternative yeasts for bread dough leavening, and provide a general experimental framework for the evaluation of more yeasts and bacteria.

  7. Atraumatic restorative treatment versus conventional restorative treatment for managing dental caries.

    Science.gov (United States)

    Dorri, Mojtaba; Martinez-Zapata, Maria José; Walsh, Tanya; Marinho, Valeria Cc; Sheiham Deceased, Aubrey; Zaror, Carlos

    2017-12-28

    Dental caries is a sugar-dependent disease that damages tooth structure and, due to loss of mineral components, may eventually lead to cavitation. Dental caries is the most prevalent disease worldwide and is considered the most important burden of oral health. Conventional treatment methods (drill and fill) involve the use of rotary burs under local anaesthesia. The need for an electricity supply, expensive handpieces and highly trained dental health personnel may limit access to dental treatment, especially in underdeveloped regions.To overcome the limitations of conventional restorative treatment, the Atraumatic Restorative Treatment (ART) was developed, mainly for treating caries in children living in under-served areas of the world where resources and facilities such as electricity and trained manpower are limited. ART is a minimally invasive approach which involves removal of decayed tissue using hand instruments alone, usually without use of anaesthesia and electrically driven equipment, and restoration of the dental cavity with an adhesive material (glass ionomer cement (GIC), composite resins, resin-modified glass-ionomer cement (RM-GICs) and compomers). To assess the effects of Atraumatic Restorative Treatment (ART) compared with conventional treatment for managing dental caries lesions in the primary and permanent teeth of children and adults. Cochrane Oral Health's Information Specialist searched the following databases: Cochrane Oral Health's Trials Register (to 22 February 2017), the Cochrane Central Register of Controlled Trials (CENTRAL) (the Cochrane Library, 2017, Issue 1), MEDLINE Ovid (1946 to 22 February 2017), Embase Ovid (1980 to 22 February 2017), LILACS BIREME Virtual Health Library (Latin American and Caribbean Health Science Information database; 1982 to 22 February 2017) and BBO BIREME Virtual Health Library (Bibliografia Brasileira de Odontologia; 1986 to 22 February 2017). The US National Institutes of Health Trials Registry (Clinical

  8. Progress towards a convention on the safe management of radioactive waste

    International Nuclear Information System (INIS)

    Webb, G.A.M.; Jankowitsch, O.

    1996-01-01

    The Convention on Nuclear Safety was prepared during the period 1992 to 1994 and after consideration by a diplomatic conference in June 1994 was opened for signature at the general conference of the IAEA in September 1994. The matter of the safety of radioactive waste was discussed many times during the development of the convention but it was eventually decided to restrict the coverage to matters concerned with nuclear safety of land-based civil nuclear power plants and those aspects of radioactive waste management directly connected with and carried out on the same site as the power plant. In the preamble to the convention, however, item (ix) affirms 'the need to begin promptly the development of an international convention on the safety of radioactive waste management as soon as the ongoing process to develop waste management safety fundamentals has resulted in broad international agreement'. In September 1994, the general conference of the IAEA also passed a resolution inviting the board of governors and the director general to commence preparations for a convention on the safety of radioactive waste management. The director general therefore organized a preparatory meeting of experts from member states to discuss the basic concepts and the possible scope of such a convention and to examine working methods and the procedures for its preparation. This meeting which took place in February 1995 prepared a paper entitled 'Inventory of Issues Raised' and proposed that the appropriate mechanism would be the setting up of an open-ended group of legal and technical experts to prepare the convention. The Safety Series document at the fundamentals level on the principles of radioactive waste management was approved by the Board of Governors in March 1995 and all the initial preconditions for starting work on the convention were then fulfilled. (author)

  9. Speech Perception Benefits of Internet Versus Conventional Telephony for Hearing-Impaired Individuals

    Science.gov (United States)

    Dubach, Patrick; Pfiffner, Flurin; Kompis, Martin; Caversaccio, Marco

    2012-01-01

    Background Telephone communication is a challenge for many hearing-impaired individuals. One important technical reason for this difficulty is the restricted frequency range (0.3–3.4 kHz) of conventional landline telephones. Internet telephony (voice over Internet protocol [VoIP]) is transmitted with a larger frequency range (0.1–8 kHz) and therefore includes more frequencies relevant to speech perception. According to a recently published, laboratory-based study, the theoretical advantage of ideal VoIP conditions over conventional telephone quality has translated into improved speech perception by hearing-impaired individuals. However, the speech perception benefits of nonideal VoIP network conditions, which may occur in daily life, have not been explored. VoIP use cannot be recommended to hearing-impaired individuals before its potential under more realistic conditions has been examined. Objective To compare realistic VoIP network conditions, under which digital data packets may be lost, with ideal conventional telephone quality with respect to their impact on speech perception by hearing-impaired individuals. Methods We assessed speech perception using standardized test material presented under simulated VoIP conditions with increasing digital data packet loss (from 0% to 20%) and compared with simulated ideal conventional telephone quality. We monaurally tested 10 adult users of cochlear implants, 10 adult users of hearing aids, and 10 normal-hearing adults in the free sound field, both in quiet and with background noise. Results Across all participant groups, mean speech perception scores using VoIP with 0%, 5%, and 10% packet loss were 15.2% (range 0%–53%), 10.6% (4%–46%), and 8.8% (7%–33%) higher, respectively, than with ideal conventional telephone quality. Speech perception did not differ between VoIP with 20% packet loss and conventional telephone quality. The maximum benefits were observed under ideal VoIP conditions without packet loss and

  10. Conventional and two step sintering of PZT-PCN ceramics

    Science.gov (United States)

    Keshavarzi, Mostafa; Rahmani, Hooman; Nemati, Ali; Hashemi, Mahdieh

    2018-02-01

    In this study, PZT-PCN ceramic was made via sol-gel seeding method and effects of conventional sintering (CS) as well as two-step sintering (TSS) were investigated on microstructure, phase formation, density, dielectric and piezoelectric properties. First, high quality powder was achieved by seeding method in which the mixture of Co3O4 and Nb2O5 powder was added to the prepared PZT sol to form PZT-PCN gel. After drying and calcination, pyrochlore free PZT-PCN powder was synthesized. Second, CS and TSS were applied to achieve dense ceramic. The optimum temperature used for 2 h of conventional sintering was obtained at 1150 °C; finally, undesired ZrO2 phase formed in CS procedure was removed successfully with TSS procedure and dielectric and piezoelectric properties were improved compared to the CS procedure. The best electrical properties obtained for the sample sintered by TSS in the initial temperature of T 1 = 1200 °C and secondary temperature of T 2 = 1000 °C for 12 h.

  11. Awareness and use of non-conventional tobacco products among U.S. students, 2012.

    Science.gov (United States)

    Wang, Baoguang; King, Brian A; Corey, Catherine G; Arrazola, René A; Johnson, Sarah E

    2014-08-01

    Increasing diversity of the tobacco product landscape, including electronic cigarettes (e-cigarettes), hookah, snus, and dissolvable tobacco products (dissolvables), raises concerns about the public health impact of these non-conventional tobacco products among youth. This study assessed awareness, ever use, and current use of non-conventional tobacco products among U.S. students in 2012, overall and by demographic and tobacco use characteristics. Data from the 2012 National Youth Tobacco Survey, a nationally representative survey of U.S. middle and high school students, were analyzed in 2013. Prevalence of awareness, ever use, and current use of e-cigarettes, hookah, snus, and dissolvables were calculated overall and by sex, school level, race/ethnicity, and conventional tobacco product use, including cigarettes, cigars, or smokeless tobacco (chewing tobacco, snuff, or dip). Overall, 50.3% of students were aware of e-cigarettes; prevalence of ever and current use of e-cigarettes was 6.8% and 2.1%, respectively. Awareness of hookah was 41.2% among all students, and that of ever and current use were 8.9% and 3.6%, respectively. Overall awareness; ever; and current use of snus (32%, 5.3%, 1.7%, respectively) and dissolvables (19.3%, 2.0%, 0.7%, respectively) were generally lower than those of e-cigarettes or hookah. Conventional tobacco product users were more likely to be aware of and to use non-conventional tobacco products. Many U.S. students are aware of and use non-conventional tobacco products. Evidence-based interventions should be implemented to prevent and reduce all tobacco use among youth. Published by Elsevier Inc.

  12. Comparisons of fully automated syphilis tests with conventional VDRL and FTA-ABS tests.

    Science.gov (United States)

    Choi, Seung Jun; Park, Yongjung; Lee, Eun Young; Kim, Sinyoung; Kim, Hyon-Suk

    2013-06-01

    Serologic tests are widely used for the diagnosis of syphilis. However, conventional methods require well-trained technicians to produce reliable results. We compared automated nontreponemal and treponemal tests with conventional methods. The HiSens Auto Rapid Plasma Reagin (AutoRPR) and Treponema Pallidum particle agglutination (AutoTPPA) tests, which utilize latex turbidimetric immunoassay, were assessed. A total of 504 sera were assayed by AutoRPR, AutoTPPA, conventional VDRL and FTA-ABS. Among them, 250 samples were also tested by conventional TPPA. The concordance rate between the results of VDRL and AutoRPR was 67.5%, and 164 discrepant cases were all VDRL reactive but AutoRPR negative. In the 164 cases, 133 showed FTA-ABS reactivity. Medical records of 106 among the 133 cases were reviewed, and 82 among 106 specimens were found to be collected from patients already treated for syphilis. The concordance rate between the results of AutoTPPA and FTA-ABS was 97.8%. The results of conventional TPPA and AutoTPPA for 250 samples were concordant in 241 cases (96.4%). AutoRPR showed higher specificity than that of VDRL, while VDRL demonstrated higher sensitivity than that of AutoRPR regardless of whether the patients had been already treated for syphilis or not. Both FTA-ABS and AutoTPPA showed high sensitivities and specificities greater than 98.0%. Automated RPR and TPPA tests could be alternatives to conventional syphilis tests, and AutoRPR would be particularly suitable in treatment monitoring, since results by AutoRPR in cases after treatment became negative more rapidly than by VDRL. Copyright © 2013. Published by Elsevier Inc.

  13. Rhegmatogenous retinal detachment and conventional surgical treatment.

    Science.gov (United States)

    Golubovic, M

    2013-01-01

    . According to the present risk factor, high myopia was found in 5 patients, which has been emphasized to be a significant risk factor for onset of retinal detachment. Lattice degeneration was the most common peripheral degenerative change. The most frequently found was horseshoe retinal hole with vitreous traction and the break location was most common in the upper retinal quadrants. The most commonly applied type was limbus radial buckle with encircling band, depending on the pathological process in the eye. The retina was postoperatively attached in 31 eyes. In two cases, the retina was not attached; in one eye due to the inadequately inserted implant and in the other case due to the larger number of breaks (3) with more distinct PVR (C2), and postoperative inflammation and proliferative components were more intensified. In one patient who did not have a total detachment, but had a larger break placed posterior to the equator and PVR C1, redetachment appeared one month later due to a manifested fibroproliferative reaction, although the break was closed. Regarding visual acuity, the day following the surgery there was no improvement; moreover, there was a small decline of visual acuity due to exudates in the vitreous body and vitreous hemorrhage. After 3 months, there was a significant improvement in the largest number of eyes. Intraoperative complications included intravitreous hemorrhage, and postoperative more distinct proliferative component in the vitreous body was found in two patients. Timely diagnosis and intervention in retinal detachment by application of an adequate method and less invasive technique gives excellent results in postoperative morbidity rate and rehabilitation of the vision. The results of the conventional treatment of retinal detachment justify its application in the treatment of this disease.

  14. Dural ectasia and conventional radiography in the Marfan lumbosacral spine

    International Nuclear Information System (INIS)

    Ahn, N.U.; Nallamshetty, L.; Ahn, U.M.; Buchowski, J.M.; Kebaish, K.M.; Sponseller, P.D.; Rose, P.S.; Garrett, E.S.

    2001-01-01

    Objective. To determine how well conventional radiographic findings can predict the presence of dural ectasia in Marfan patients.Design and patients. Twelve Marfan patients without dural ectasia and 21 Marfan patients with dural ectasia were included in the study. Five radiographic measurements were made of the lumbosacral spine: interpediculate distance, scalloping value, sagittal canal diameter, vertebral body width, and transverse process width.Results. The following measurements were significantly larger in patients with dural ectasia: interpediculate distances at L3-L4 levels (P 38.0 mm, sagittal diameter at S1 >18.0 mm, or scalloping value at L5 >5.5 mm.Conclusion. Dural ectasia in Marfan syndrome is commonly associated with several osseous changes that are observable on conventional radiographs of the lumbosacral spine. Conventional radiography can detect dural ectasia in patients with Marfan syndrome with a very high specificity (91.7%) but a low sensitivity (57.1%). (orig.)

  15. Comparison of the Debonding Characteristics of Conventional and New Debonding Instrument used for Ceramic, Composite and Metallic Brackets – An Invitro Study

    Science.gov (United States)

    Gill, Vikas; Reddy, Y. N. N.; Sanadhya, Sudhanshu; Aapaliya, Pankaj; Sharma, Nidhi

    2014-01-01

    Background: Debonding procedure is time consuming and damaging to the enamel if performed with improper technique. Various debonding methods include: the conventional methods that use pliers or wrenches, an ultrasonic method, electrothermal devices, air pressure impulse devices, diamond burs to grind the brackets off the tooth surface and lasers. Among all these methods, using debonding pliers is most convenient and effective method but has been reported to cause damage to the teeth. Recently, a New Debonding Instrument designed specifically for ceramic and composite brackets has been introduced. As this is a new instrument, little information is available on efficacy of this instrument. The purpose of this study was to evaluate the debonding characteristics of both “the conventional debonding Pliers” and “the New debonding instrument” when removing ceramic, composite and metallic brackets. Materials and Methods: One Hundred Thirty eight extracted maxillary premolar teeth were collected and divided into two Groups: Group A and Group B (n = 69) respectively. They were further divided into 3 subGroups (n = 23) each according to the types of brackets to be bonded. In subGroups A1 and B1{stainless steel};A2 and B2{ceramic};A3 and B3{composite}adhesive precoated maxillary premolar brackets were used. Among them {ceramic and composite} adhesive pre-coated maxillary premolar brackets were bonded. All the teeth were etched using 37% phosphoric acid for 15 seconds and the brackets were bonded using Transbond XT primer. Brackets were debonded using Conventional Debonding Plier and New Debonding Instrument (Group B). After debonding, the enamel surface of each tooth was examined under stereo microscope (10X magnifications). Amodifiedadhesive remnant index (ARI) was used to quantify the amount of remaining adhesive on each tooth. Results: The observations demonstrate that the results of New Debonding Instrument for debonding of metal, ceramic and composite brackets

  16. SELECTION OF NON-CONVENTIONAL MACHINING PROCESSES USING THE OCRA METHOD

    Directory of Open Access Journals (Sweden)

    Miloš Madić

    2015-04-01

    Full Text Available Selection of the most suitable nonconventional machining process (NCMP for a given machining application can be viewed as multi-criteria decision making (MCDM problem with many conflicting and diverse criteria. To aid these selection processes, different MCDM methods have been proposed. This paper introduces the use of an almost unexplored MCDM method, i.e. operational competitiveness ratings analysis (OCRA method for solving the NCMP selection problems. Applicability, suitability and computational procedure of OCRA method have been demonstrated while solving three case studies dealing with selection of the most suitable NCMP. In each case study the obtained rankings were compared with those derived by the past researchers using different MCDM methods. The results obtained using the OCRA method have good correlation with those derived by the past researchers which validate the usefulness of this method while solving complex NCMP selection problems.

  17. Tomographs based on non-conventional radiation sources and methods

    International Nuclear Information System (INIS)

    Barbuzza, R.; Fresno, M. del; Venere, Marcelo J.; Clausse, Alejandro; Moreno, C.

    2000-01-01

    Computer techniques for tomographic reconstruction of objects X-rayed with a compact plasma focus (PF) are presented. The implemented reconstruction algorithms are based on stochastic searching of solutions of Radon equation, using Genetic Algorithms and Monte Carlo methods. Numerical experiments using actual projections were performed concluding the feasibility of the application of both methods in tomographic reconstruction problem. (author)

  18. Optimal fuzzy logic-based PID controller for load-frequency control including superconducting magnetic energy storage units

    International Nuclear Information System (INIS)

    Pothiya, Saravuth; Ngamroo, Issarachai

    2008-01-01

    This paper proposes a new optimal fuzzy logic-based-proportional-integral-derivative (FLPID) controller for load frequency control (LFC) including superconducting magnetic energy storage (SMES) units. Conventionally, the membership functions and control rules of fuzzy logic control are obtained by trial and error method or experiences of designers. To overcome this problem, the multiple tabu search (MTS) algorithm is applied to simultaneously tune PID gains, membership functions and control rules of FLPID controller to minimize frequency deviations of the system against load disturbances. The MTS algorithm introduces additional techniques for improvement of search process such as initialization, adaptive search, multiple searches, crossover and restarting process. Simulation results explicitly show that the performance of the optimum FLPID controller is superior to the conventional PID controller and the non-optimum FLPID controller in terms of the overshoot, settling time and robustness against variations of system parameters

  19. Merchant shipping (Safety Convention) Act 1977

    International Nuclear Information System (INIS)

    1977-01-01

    When this Act comes into force, it will enable the United Kingdom to ratify and to give effect to the 1974 International Convention for the Safety of Life at Sea (the SOLAS Convention) which replaces the SOLAS Convention of 1960. Under the Act, the Secretary of State may make such rules as he considers appropriate regarding ships provided with nuclear power plants in accordance with Chapter VIII of the Annex to the 1974 Convention and to Recommendations attached to it, dealing with nuclear ships, and insofar as those provisions have not been implemented by the Merchant Shipping Acts 1894 to 1974. (NEA) [fr

  20. Dilution Confusion: Conventions for Defining a Dilution

    Science.gov (United States)

    Fishel, Laurence A.

    2010-01-01

    Two conventions for preparing dilutions are used in clinical laboratories. The first convention defines an "a:b" dilution as "a" volumes of solution A plus "b" volumes of solution B. The second convention defines an "a:b" dilution as "a" volumes of solution A diluted into a final volume of "b". Use of the incorrect dilution convention could affect…

  1. Low-dose phase contrast tomography with conventional x-ray sources

    Energy Technology Data Exchange (ETDEWEB)

    Hagen, C. K., E-mail: charlotte.hagen.10@ucl.ac.uk; Endrizzi, M.; Diemoz, P. C.; Olivo, A. [Department of Medical Physics and Bioengineering, University College London, Malet Place, Gower Street, London WC1E 6BT (United Kingdom); Munro, P. R. T. [Optical + Biomedical Engineering Laboratory, School of Electrical, Electronic and Computer Engineering, The University of Western Australia, 35 Stirling Highway, Crawley, Western Australia 6009, Australia and Centre for Microscopy, Characterisation, and Analysis, The University of Western Australia, 35 Stirling Highway, Crawley, Western Australia 6009 (Australia)

    2014-07-15

    Purpose: The edge illumination (EI) x-ray phase contrast imaging (XPCi) method has been recently further developed to perform tomographic and, thus, volumetric imaging. In this paper, the first tomographic EI XPCi images acquired with a conventional x-ray source at dose levels below that used for preclinical small animal imaging are presented. Methods: Two test objects, a biological sample and a custom-built phantom, were imaged with a laboratory-based EI XPCi setup in tomography mode. Tomographic maps that show the phase shift and attenuating properties of the object were reconstructed, and analyzed in terms of signal-to-noise ratio and quantitative accuracy. Dose measurements using thermoluminescence devices were performed. Results: The obtained images demonstrate that phase based imaging methods can provide superior results compared to attenuation based modalities for weakly attenuating samples also in 3D. Moreover, and, most importantly, they demonstrate the feasibility of low-dose imaging. In addition, the experimental results can be considered quantitative within the constraints imposed by polychromaticity. Conclusions: The results, together with the method's dose efficiency and compatibility with conventional x-ray sources, indicate that tomographic EI XPCi can become an important tool for the routine imaging of biomedical samples.

  2. The comparison of assessment of pigeon semen motility and sperm concentration by conventional methods and the CASA system (HTM IVOS).

    Science.gov (United States)

    Klimowicz, M D; Nizanski, W; Batkowski, F; Savic, M A

    2008-07-01

    The aim of these experiments was to compare conventional, microscopic methods of evaluating pigeon sperm motility and concentration to those measured by computer-assisted sperm analysis (CASA system). Semen was collected twice a week from two groups of pigeons, each of 40 males (group I: meat-type breed; group II: fancy pigeon) using the lumbo-sacral and cloacal region massage method. Ejaculates collected in each group were diluted 1:100 in BPSE solution and divided into two equal samples. One sample was examined subjectively by microscope and the second one was analysed using CASA system. The sperm concentration was measured by CASA using the anti-collision (AC) system and fluorescent staining (IDENT). There were not any significant differences between the methods of evaluation of sperm concentration. High positive correlations in both groups were observed between the sperm concentration estimated by Thom counting chamber and AC (r=0.87 and r=0.91, respectively), and between the sperm concentration evaluated by Thom counting chamber and IDENT (r=0.85 and r=0.90, respectively). The mean values for CASA measurement of proportion of motile spermatozoa (MOT) and progressive movement (PMOT) were significantly lower than the values estimated subjectively in both groups of pigeons (pCASA system is very rapid, objective and sensitive method in detecting subtle motility characteristics as well as sperm concentration and is recommended for future research into pigeon semen.

  3. Evaluation of marginal and internal gaps of metal ceramic crowns obtained from conventional impressions and casting techniques with those obtained from digital techniques

    Directory of Open Access Journals (Sweden)

    Rathika Rai

    2017-01-01

    Full Text Available Background: Accuracy in fit of cast metal restoration has always remained as one of the primary factors in determining the success of the restoration. A well-fitting restoration needs to be accurate both along its margin and with regard to its internal surface. Aim: The aim of the study is to evaluate the marginal fit of metal ceramic crowns obtained by conventional inlay casting wax pattern using conventional impression with the metal ceramic crowns obtained by computer-aided design and computer-aided manufacturing (CAD/CAM technique using direct and indirect optical scanning. Materials and Methods: This in vitro study on preformed custom-made stainless steel models with former assembly that resembles prepared tooth surfaces of standardized dimensions comprised three groups: the first group included ten samples of metal ceramic crowns fabricated with conventional technique, the second group included CAD/CAM-milled direct metal laser sintering (DMLS crowns using indirect scanning, and the third group included DMLS crowns fabricated by direct scanning of the stainless steel model. The vertical marginal gap and the internal gap were evaluated with the stereomicroscope (Zoomstar 4; post hoc Turkey's test was used for statistical analysis. One-way analysis of variance method was used to compare the mean values. Results and Conclusion: Metal ceramic crowns obtained from direct optical scanning showed the least marginal and internal gap when compared to the castings obtained from inlay casting wax and indirect optical scanning. Indirect and direct optical scanning had yielded results within clinically acceptable range.

  4. Spiral CT versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies

    International Nuclear Information System (INIS)

    Prokesch, R.; Bankier, A.; Ba-Ssalamah, A.; Imhof, H.; Lakits, A.; Scholda, C.

    1998-01-01

    Purpose: To compare the effectiveness of spiral CT versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies. Results: All foreign bodies were detected by each scanning modality on the axial and on the reconstructed planes. The quality of the axial images was similar for spiral and conventional CT. The spiral technique provided high-quality reconstructed images which allowed accurate localization of the foreign bodies in all cases. Reconstructions by conventional technique were inadequate for preoperative assessment. The examination time for the total orbital volume was 18 s for spiral CT and 52 s for conventional CT. Radiation dose delivered to the lens was 35 mGy for spiral CT and 56 mGy for conventional CT axial scanning. Conclusion: Spiral CT multiplanar offers several significant advantages for the preoperative assessment of metallic intraocular foreign bodies compared to the conventional CT technique in clinical practice, including short examination time, minimized motion artifacts, reduced radiation exposure, and accurate localization. (orig.) [de

  5. Comparative evaluation of matrix-assisted laser desorption ionisation-time of flight mass spectrometry and conventional phenotypic-based methods for identification of clinically important yeasts in a UK-based medical microbiology laboratory.

    Science.gov (United States)

    Fatania, Nita; Fraser, Mark; Savage, Mike; Hart, Jason; Abdolrasouli, Alireza

    2015-12-01

    Performance of matrix-assisted laser desorption ionisation-time of flight mass spectrometry (MALDI-TOF MS) was compared in a side-by side-analysis with conventional phenotypic methods currently in use in our laboratory for identification of yeasts in a routine diagnostic setting. A diverse collection of 200 clinically important yeasts (19 species, five genera) were identified by both methods using standard protocols. Discordant or unreliable identifications were resolved by sequencing of the internal transcribed spacer region of the rRNA gene. MALDI-TOF and conventional methods were in agreement for 182 isolates (91%) with correct identification to species level. Eighteen discordant results (9%) were due to rarely encountered species, hence the difficulty in their identification using traditional phenotypic methods. MALDI-TOF MS enabled rapid, reliable and accurate identification of clinically important yeasts in a routine diagnostic microbiology laboratory. Isolates with rare, unusual or low probability identifications should be confirmed using robust molecular methods. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  6. The evolution of development conventions

    Directory of Open Access Journals (Sweden)

    Fabio Stefano Erber

    2012-04-01

    Full Text Available This paper presents a conceptual view on development and its translation into development policies. It argues that society's perception of development is structured by conventions, which provide a view of the past, present and future and, at the same time, allows a certain hierarchy of problems and solutions to such problems. The prevalence of a specific convention depends on the international conditions faced by this society and on the distribution of economic and political power within that society. Therefore, in complex societies there is always a struggle for hegemony between competing development conventions.

  7. Differences between postmortem computed tomography and conventional autopsy in a stabbing murder case

    Directory of Open Access Journals (Sweden)

    Talita Zerbini

    2014-12-01

    Full Text Available Objective: The aim of the present work is to analyze the differences and similarities between the elements of a conventional autopsy and images obtained from postmortem computed tomography in a case of a homicide stab wound. Method: Comparison between the findings of different methods: autopsy and postmortem computed tomography. Results: In some aspects, autopsy is still superior to imaging, especially in relation to external examination and the description of lesion vitality. However, the findings of gas embolism, pneumothorax and pulmonary emphysema and the relationship between the internal path of the instrument of aggression and the entry wound are better demonstrated by postmortem computed tomography. Conclusions: Although multislice computed tomography has greater accuracy than autopsy, we believe that the conventional autopsy method is fundamental for providing evidence in criminal investigations.

  8. Near infrared hyperspectral imaging of blends of conventional and waxy hard wheats

    Directory of Open Access Journals (Sweden)

    Stephen R. Delwiche

    2018-02-01

    Full Text Available Recent development of hard winter waxy (amylose-free wheat adapted to the North American climate has prompted the quest to find a rapid method that will determine mixture levels of conventional wheat in lots of identity preserved waxy wheat. Previous work documented the use of conventional near infrared (NIR reflectance spectroscopy to determine the mixture level of conventional wheat in waxy wheat, with an examined range, through binary sample mixture preparation, of 0–100% (weight conventional / weight total. The current study examines the ability of NIR hyperspectral imaging of intact kernels to determine mixture levels. Twenty-nine mixtures (0, 1, 2, 3, 4, 5, 10, 15, …, 95, 96, 97, 98, 99, 100% were formed from known genotypes of waxy and conventional wheat. Two-class partial least squares discriminant analysis (PLSDA and statistical pattern recognition classifier models were developed for identifying each kernel in the images as conventional or waxy. Along with these approaches, conventional PLS1 regression modelling was performed on means of kernel spectra within each mixture test sample. Results indicated close agreement between all three approaches, with standard errors of prediction for the better preprocess transformations (PLSDA models or better classifiers (pattern recognition models of approximately 9 percentage units. Although such error rates were slightly greater than ones previously published using non-imaging NIR analysis of bulk whole kernel wheat and wheat meal, the HSI technique offers an advantage of its potential use in sorting operations.

  9. Teaching Methods in Biology Education and Sustainability Education Including Outdoor Education for Promoting Sustainability—A Literature Review

    Directory of Open Access Journals (Sweden)

    Eila Jeronen

    2016-12-01

    Full Text Available There are very few studies concerning the importance of teaching methods in biology education and environmental education including outdoor education for promoting sustainability at the levels of primary and secondary schools and pre-service teacher education. The material was selected using special keywords from biology and sustainable education in several scientific databases. The article provides an overview of 24 selected articles published in peer-reviewed scientific journals from 2006–2016. The data was analyzed using qualitative content analysis. Altogether, 16 journals were selected and 24 articles were analyzed in detail. The foci of the analyses were teaching methods, learning environments, knowledge and thinking skills, psychomotor skills, emotions and attitudes, and evaluation methods. Additionally, features of good methods were investigated and their implications for teaching were emphasized. In total, 22 different teaching methods were found to improve sustainability education in different ways. The most emphasized teaching methods were those in which students worked in groups and participated actively in learning processes. Research points toward the value of teaching methods that provide a good introduction and supportive guidelines and include active participation and interactivity.

  10. Chapter 29: Unproved and controversial methods and theories in allergy-immunology.

    Science.gov (United States)

    Shah, Rachna; Greenberger, Paul A

    2012-01-01

    Unproved methods and controversial theories in the diagnosis and management of allergy-immunology are those that lack scientific credibility. Some definitions are provided for perspective because in chronic medical conditions, frequently, nonscientifically based treatments are developed that can have a very positive psychological effect on the patients in the absence of objective physical benefit. Standard practice can be described as "the methods of diagnosis and treatment used by reputable physicians in a particular subspecialty or primary care practice" with the understanding that diagnosis and treatment options are consistent with established mechanisms of conditions or diseases.(3) Conventional medicine (Western or allopathic medicine) is that which is practiced by the majority of MDs, DOs, psychologists, RNs, and physical therapists. Complementary medicine uses the practice of conventional medicine with complementary and alternative medicine such as using acupuncture for pain relief in addition to opioids. Alternative medicine implies use of complementary and alternative practices in place of conventional medicine. Unproved and controversial methods and theories do not have supporting data, validation, and sufficient scientific scrutiny, and they should not be used in the practice of allergy-immunology. Some examples of unproven theories about allergic immunologic conditions include allergic toxemia, idiopathic environmental intolerance, association with childhood vaccinations, and adrenal fatigue. Unconventional (unproved) diagnostic methods for allergic-immunologic conditions include cytotoxic tests, provocation-neutralization, electrodermal diagnosis, applied kinesiology assessments, and serum IgG or IgG(4) testing. Unproven treatments and intervention methods for allergic-immunologic conditions include acupuncture, homeopathy ("likes cure likes"), halotherapy, and autologous urine injections.

  11. Meniscal tears: comparison of half-Fourier technique and conventional MR imaging

    International Nuclear Information System (INIS)

    Shabana, Wael; Maeseneer, Michel de; Machiels, Freddy; Ridder, Filip de; Osteaux, Michel

    2003-01-01

    Purpose: To determine whether half-Fourier MR image acquisition technique can provide similar information to that of conventional MR acquisition technique for evaluation of meniscal tears. Materials and methods: We studied 101 menisci in 52 patients who were referred for evaluation of meniscal tears. Sagittal MR images of the knee were obtained for all patients by using proton density and T2-weighted SE sequences on a 1-T clinical system. The half-Fourier technique and conventional technique were used for all patients. All other imaging parameters were identical for both sequences (TR/TE=2400/20,70; 3 mm slice thickness; 200x256 matrix; field of view, 200; one signal acquired). Both sets of images were filmed with standard window and level settings. Images were randomised and interpreted independently by two radiologists for the presence of meniscal tears. Images were also subjectively assessed for image quality using a five-point grading scale. Results: On half-Fourier images, Reader 1 interpreted 23 menisci as torn, compared to 28 for Reader 2. On conventional images, Reader 1 interpreted 24 menisci as torn, compared to 26 for Reader 2. Agreement between interpretation of the conventional and that of the half-Fourier images was 99% for Reader 1, and 98% for Reader 2. Agreement between readers for the half-Fourier images was 95%, and for the conventional images 96%. No statistically significant difference was found in the subjective evaluation of image quality between the conventional and half-Fourier images. Conclusion: The half-Fourier acquisition technique compares favourably with the conventional technique for the evaluation of meniscal tears

  12. The sustainability transition. Beyond conventional development

    Energy Technology Data Exchange (ETDEWEB)

    Raskin, P; Chadwick, M; Jackson, T; Leach, G

    1996-10-01

    This paper synthesizes findings of the first phase in SEI`s PoleStar Project - a project aimed at developing long-term strategies and policies for sustainable development. Taking a global and long-range perspective, the paper aims to describe a theoretical framework for addressing sustainability, to identify emerging issues and outline directions for future action. The paper begins by setting today`s development and environmental challenges in historical context, and describing the scenario method for envisioning and evaluating alternative futures, and identifying propitious areas for policy and action. It next summarizes a detailed scenario based on conventional development assumptions, and discusses the implications of this scenario for demographic and economic patterns, energy and water resources, land resources and agriculture, and pollution loads and the environment to the year 2050. The conventional scenario relies in part on the sectorally-oriented work discussed in Papers 3 through 6 of the PoleStar Project report series, and makes use of the PoleStar System, software designed for integrated resource, environment and socio-economic accounting and scenario analysis (described in Paper 2). The paper then examines the critical risks to social, resource and environmental systems lying ahead on the conventional development path. Finally, the paper surveys the requirements for sustainability across a number of policy dimensions, and raises key questions for the future. The PoleStar Project is proceeding to examine a range of alternative development scenarios, in the context of the work of the regionally-diverse Global Scenario Group, convened by SEI. The hope remains to offer wise counsel for a transition to an equitable, humane and sustainable future for the global community. 144 refs, 30 figs, 9 tabs

  13. The sustainability transition. Beyond conventional development

    International Nuclear Information System (INIS)

    Raskin, P.; Chadwick, M.; Jackson, T.; Leach, G.

    1996-01-01

    This paper synthesizes findings of the first phase in SEI's PoleStar Project - a project aimed at developing long-term strategies and policies for sustainable development. Taking a global and long-range perspective, the paper aims to describe a theoretical framework for addressing sustainability, to identify emerging issues and outline directions for future action. The paper begins by setting today's development and environmental challenges in historical context, and describing the scenario method for envisioning and evaluating alternative futures, and identifying propitious areas for policy and action. It next summarizes a detailed scenario based on conventional development assumptions, and discusses the implications of this scenario for demographic and economic patterns, energy and water resources, land resources and agriculture, and pollution loads and the environment to the year 2050. The conventional scenario relies in part on the sectorally-oriented work discussed in Papers 3 through 6 of the PoleStar Project report series, and makes use of the PoleStar System, software designed for integrated resource, environment and socio-economic accounting and scenario analysis (described in Paper 2). The paper then examines the critical risks to social, resource and environmental systems lying ahead on the conventional development path. Finally, the paper surveys the requirements for sustainability across a number of policy dimensions, and raises key questions for the future. The PoleStar Project is proceeding to examine a range of alternative development scenarios, in the context of the work of the regionally-diverse Global Scenario Group, convened by SEI. The hope remains to offer wise counsel for a transition to an equitable, humane and sustainable future for the global community. 144 refs, 30 figs, 9 tabs

  14. 2015 Plan. Project 7: the environmental issue and the electrical sector. The options of electrical power supply and their socio-environmental implications: sources/conventional and non-conventional technologies of generation

    International Nuclear Information System (INIS)

    1992-10-01

    The socio-environmental impacts caused by the uses of conventional sources (hydraulic, mineral coal, nuclear, petroleum by-products and natural gas) and non-conventional (biomass, solar, eolic, ocean and organic wastes) in electric power generation are presented. The main topics that integrate the environmental schedule in the last years are described, including some considerations about environmental legislation and atmospheric alterations. The reserves for each source are also cited. (C.G.C.)

  15. Comparison of peritoneal tumor imaging using conventional MR imaging and diffusion-weighted MR imaging with different b values

    Energy Technology Data Exchange (ETDEWEB)

    Bozkurt, Mahmut [Buhara Private Hospital Department of Radiology, Erzurum (Turkey); Doganay, Selim [Erciyes University, School of Medicine, Department of Radiology, Kayseri (Turkey); Kantarci, Mecit, E-mail: akkanrad@hotmail.com [Atatuerk University, School of Medicine, Department of Radiology, Erzurum (Turkey); Yalcin, Ahmet; Eren, Suat [Atatuerk University, School of Medicine, Department of Radiology, Erzurum (Turkey); Atamanalp, S. Selcuk [Atatuerk University, School of Medicine, Department of General Surgery, Erzurum (Turkey); Yuce, Ihsan [Atatuerk University, School of Medicine, Department of Radiology, Erzurum (Turkey); Yildirgan, M. Ilhan [Atatuerk University, School of Medicine, Department of General Surgery, Erzurum (Turkey)

    2011-11-15

    Purpose: The aim of this study was to evaluate the utility of DW MRI with two different b values in identifying peritoneal tumors in oncology patients. Materials and methods: Nineteen patients with known malignancy underwent abdominal and pelvic MRI before surgery. MRI included free-breathing DWI with b values of 400 and 800 s/mm{sup 2}, T1-weighted fat-suppressed spoiled gradient-echo, T2-weighted fat-saturated turbo spin-echo, and 5-min delayed gadolinium-enhanced imaging. Two observers reviewed images for peritoneal tumors at ten anatomic sites within consensus. The results of laparatomy and histopathological evaluation were compared with MRI results. Sensitivity, specificity, and accuracy of identifying peritoneal metastases were calculated for conventional MRI, combined DWI with a b value of 400 s/mm{sup 2} and conventional MRI, and combined DWI with a b value of 800 s/mm{sup 2} and conventional MRI by consensus of two observers. Results: One-hundred and twenty-five peritoneal metastasis sites were confirmed by surgical and histopathological findings. Conventional MRI alone identified 72 peritoneal metastases (sensitivity, 0.58; specificity, 0.87; accuracy, 0.67). Combined DWI with a b value of 400 s/mm{sup 2} and conventional MRI revealed 106 peritoneal metastases (sensitivity, 0.85; specificity, 0.88; accuracy, 0.85). Finally, combined DWI with a b value of 800 s/mm{sup 2} and conventional MRI revealed 103 peritoneal metastases (sensitivity, 0.83; specificity, 0.94; accuracy, 0.86). Conclusion: DWI with a high b value provides complementary information that can improve the detection of peritoneal tumors when combined with conventional MRI. We recommend combined MRI and DWI with a high b value for increasing the sensitivity and accuracy of the preoperative detection of peritoneal tumors.

  16. Comparison of peritoneal tumor imaging using conventional MR imaging and diffusion-weighted MR imaging with different b values

    International Nuclear Information System (INIS)

    Bozkurt, Mahmut; Doganay, Selim; Kantarci, Mecit; Yalcin, Ahmet; Eren, Suat; Atamanalp, S. Selcuk; Yuce, Ihsan; Yildirgan, M. Ilhan

    2011-01-01

    Purpose: The aim of this study was to evaluate the utility of DW MRI with two different b values in identifying peritoneal tumors in oncology patients. Materials and methods: Nineteen patients with known malignancy underwent abdominal and pelvic MRI before surgery. MRI included free-breathing DWI with b values of 400 and 800 s/mm 2 , T1-weighted fat-suppressed spoiled gradient-echo, T2-weighted fat-saturated turbo spin-echo, and 5-min delayed gadolinium-enhanced imaging. Two observers reviewed images for peritoneal tumors at ten anatomic sites within consensus. The results of laparatomy and histopathological evaluation were compared with MRI results. Sensitivity, specificity, and accuracy of identifying peritoneal metastases were calculated for conventional MRI, combined DWI with a b value of 400 s/mm 2 and conventional MRI, and combined DWI with a b value of 800 s/mm 2 and conventional MRI by consensus of two observers. Results: One-hundred and twenty-five peritoneal metastasis sites were confirmed by surgical and histopathological findings. Conventional MRI alone identified 72 peritoneal metastases (sensitivity, 0.58; specificity, 0.87; accuracy, 0.67). Combined DWI with a b value of 400 s/mm 2 and conventional MRI revealed 106 peritoneal metastases (sensitivity, 0.85; specificity, 0.88; accuracy, 0.85). Finally, combined DWI with a b value of 800 s/mm 2 and conventional MRI revealed 103 peritoneal metastases (sensitivity, 0.83; specificity, 0.94; accuracy, 0.86). Conclusion: DWI with a high b value provides complementary information that can improve the detection of peritoneal tumors when combined with conventional MRI. We recommend combined MRI and DWI with a high b value for increasing the sensitivity and accuracy of the preoperative detection of peritoneal tumors.

  17. Detection of lung nodules with low-dose spiral CT: comparison with conventional dose CT

    International Nuclear Information System (INIS)

    Zhu Tianzhao; Tang Guangjian; Jiang Xuexiang

    2004-01-01

    Objective: To investigate the effect of reducing scan dose on the lung nodules detection rate by scanning a lung nodule model at low dose and conventional dose. Methods: The lung and the thoracic cage were simulated by using a cyst filled with water surrounded by a roll bandage. Flour, butter, and paraffin wax were mixed together by a certain ratio to simulate lung nodules of 10 mm and 5 mm in diameter with the CT values ranging from -10 to 50 HU. Conventional-dose scan (240 mA, 140 kV) and low-dose scan of three different levels (43 mA, 140 kV; 50 mA, 120 kV; 75 mA, 80 kV) together with three different pitches (1.0, 1.5, and 2.0) were performed. The images of the simulated nodules were combined with the CT images of a normal adult's upper, middle, and inferior lung. Three radiologists read the images and the number of the nodules they detected including both the real ones and the false-positive ones was calculated to investigate weather there was any difference among different doses, pitch groups, and different locations. Results: The detection rate of the 10 mm and 5 mm nodules was 100% and 89.6% respectively by the low-dose scan. There was no difference between low-dose and conventional-dose CT (χ 2 =0.6907, P>0.70). The detection rate of 5 mm nodules declined when large pitch was used. Conclusion: The detection rates of 10 mm and 5 mm nodules had no difference between low-dose CT and conventional-dose CT. As the pitch augmented, the detection rate for the nodules declined

  18. The convention on the physical protection of nuclear material

    International Nuclear Information System (INIS)

    1980-05-01

    This document contains the full text of a convention to facilitate the safe transfer of nuclear material, and to insure the physical protection of nuclear material in domestic use, storage, and transport. Two annexes are included, which establish categories of nuclear materials and levels of physical protection to be applied in international transport

  19. Microwave and conventional preparation of Zinc borate glass: Eu3+ ion as luminescent probe

    International Nuclear Information System (INIS)

    Mandal, Ashis K.; Balaji, S.; Sen, Ranjan

    2014-01-01

    Highlights: • IR transparent Zinc borate glass is prepared using microwave heating. • Glass transition temperature of microwave melted glass is found higher than that of glass prepared in conventional melting. • Low OH concentration in glass can be prepared in microwave heating. • We report higher reduction of Eu 3+ to Eu 2+ in microwave processing of Zinc borate glass. - Abstract: Transparent Zinc borate glass is melted using microwave energy as an alternative heating route to conventional resistive heating. A comparative study of the properties of the glasses prepared by both the methods is conducted by adopting X-ray diffraction (XRD), Differential scanning calorimetry (DSC), UV–VIS–NIR spectroscopy, Fourier transform infrared (FTIR) spectroscopy, Refractive Indices (RI). Amorphous nature of samples is confirmed by X-ray diffraction study. Glass transition temperature (T g ) of microwave melted glass is found ∼7–9 °C higher than that of glass prepared in conventional melting. OH content is found less than 250 ppm in microwave melted glass whereas it is above 330 ppm in conventional melted glasses. Photoluminescence study of Eu 2 O 3 doped glass prepared in microwave heating indicates higher reduction of Eu 3+ → Eu 2+ than the glass melted in conventional route. Thus, microwave processing can be an alternative energy efficient, time saving, environmental friendly glass preparation method

  20. Strain elastography of abnormal axillary nodes in breast cancer patients does not improve diagnostic accuracy compared with conventional ultrasound alone.

    Science.gov (United States)

    Park, Young Mi; Fornage, Bruno D; Benveniste, Ana Paula; Fox, Patricia S; Bassett, Roland L; Yang, Wei Tse

    2014-12-01

    The purpose of this study was to determine the diagnostic value of strain elastography (SE) alone and in combination with gray-scale ultrasound in the diagnosis of benign versus metastatic disease for abnormal axillary lymph nodes in breast cancer patients. Patients with breast cancer and axillary lymph nodes suspicious for metastatic disease on conventional ultrasound who underwent SE of the suspicious node before ultrasound-guided fine-needle aspiration biopsy (FNAB) were included in this study. On conventional ultrasound, the long- and short-axis diameters, long-axis-to-short-axis ratio, cortical echogenicity, thickness, and evenness were documented. The nodal vascularity was assessed on power Doppler imaging. Elastograms were evaluated for the percentage of black (hard) areas in the lymph node, and the SE-ultrasound size ratio was calculated. Two readers assessed the images independently and then in consensus in cases of disagreement. ROC AUCs were calculated for conventional ultrasound, SE, and both methods combined. Interreader reliability was assessed using kappa statistics. A total of 101 patients with 104 nodes were examined; 35 nodes were benign, and 69 had metastases. SE alone showed a significantly lower AUC (62%) than did conventional ultrasound (92%) (pultrasound and the AUC of the combination of conventional ultrasound and SE (93%) (p=0.16). Interreader reliability was moderate for all variables (κ≥0.60) except the SE-ultrasound size ratio (κ=0.35). Added SE does not improve the diagnostic ability of conventional ultrasound when evaluating abnormal axillary lymph nodes.