WorldWideScience

Sample records for methods gas detection

  1. Minimum detectable gas concentration performance evaluation method for gas leak infrared imaging detection systems.

    Science.gov (United States)

    Zhang, Xu; Jin, Weiqi; Li, Jiakun; Wang, Xia; Li, Shuo

    2017-04-01

    Thermal imaging technology is an effective means of detecting hazardous gas leaks. Much attention has been paid to evaluation of the performance of gas leak infrared imaging detection systems due to several potential applications. The minimum resolvable temperature difference (MRTD) and the minimum detectable temperature difference (MDTD) are commonly used as the main indicators of thermal imaging system performance. This paper establishes a minimum detectable gas concentration (MDGC) performance evaluation model based on the definition and derivation of MDTD. We proposed the direct calculation and equivalent calculation method of MDGC based on the MDTD measurement system. We build an experimental MDGC measurement system, which indicates the MDGC model can describe the detection performance of a thermal imaging system to typical gases. The direct calculation, equivalent calculation, and direct measurement results are consistent. The MDGC and the minimum resolvable gas concentration (MRGC) model can effectively describe the performance of "detection" and "spatial detail resolution" of thermal imaging systems to gas leak, respectively, and constitute the main performance indicators of gas leak detection systems.

  2. Infrared video based gas leak detection method using modified FAST features

    Science.gov (United States)

    Wang, Min; Hong, Hanyu; Huang, Likun

    2018-03-01

    In order to detect the invisible leaking gas that is usually dangerous and easily leads to fire or explosion in time, many new technologies have arisen in the recent years, among which the infrared video based gas leak detection is widely recognized as a viable tool. However, all the moving regions of a video frame can be detected as leaking gas regions by the existing infrared video based gas leak detection methods, without discriminating the property of each detected region, e.g., a walking person in a video frame may be also detected as gas by the current gas leak detection methods.To solve this problem, we propose a novel infrared video based gas leak detection method in this paper, which is able to effectively suppress strong motion disturbances.Firstly, the Gaussian mixture model(GMM) is used to establish the background model.Then due to the observation that the shapes of gas regions are different from most rigid moving objects, we modify the Features From Accelerated Segment Test (FAST) algorithm and use the modified FAST (mFAST) features to describe each connected component. In view of the fact that the statistical property of the mFAST features extracted from gas regions is different from that of other motion regions, we propose the Pixel-Per-Points (PPP) condition to further select candidate connected components.Experimental results show that the algorithm is able to effectively suppress most strong motion disturbances and achieve real-time leaking gas detection.

  3. Anomaly Detection in Gas Turbine Fuel Systems Using a Sequential Symbolic Method

    Directory of Open Access Journals (Sweden)

    Fei Li

    2017-05-01

    Full Text Available Anomaly detection plays a significant role in helping gas turbines run reliably and economically. Considering the collective anomalous data and both sensitivity and robustness of the anomaly detection model, a sequential symbolic anomaly detection method is proposed and applied to the gas turbine fuel system. A structural Finite State Machine is used to evaluate posterior probabilities of observing symbolic sequences and the most probable state sequences they may locate. Hence an estimation-based model and a decoding-based model are used to identify anomalies in two different ways. Experimental results indicate that both models have both ideal performance overall, but the estimation-based model has a strong robustness ability, whereas the decoding-based model has a strong accuracy ability, particularly in a certain range of sequence lengths. Therefore, the proposed method can facilitate well existing symbolic dynamic analysis- based anomaly detection methods, especially in the gas turbine domain.

  4. Method and apparatus for continuously detecting and monitoring the hydrocarbon dew-point of gas

    Energy Technology Data Exchange (ETDEWEB)

    Boyle, G.J.; Pritchard, F.R.

    1987-08-04

    This patent describes a method and apparatus for continuously detecting and monitoring the hydrocarbon dew-point of a gas. A gas sample is supplied to a dew-point detector and the temperature of a portion of the sample gas stream to be investigated is lowered progressively prior to detection until the dew-point is reached. The presence of condensate within the flowing gas is detected and subsequently the supply gas sample is heated to above the dew-point. The procedure of cooling and heating the gas stream continuously in a cyclical manner is repeated.

  5. Establishment of analysis method for methane detection by gas chromatography

    Science.gov (United States)

    Liu, Xinyuan; Yang, Jie; Ye, Tianyi; Han, Zeyu

    2018-02-01

    The study focused on the establishment of analysis method for methane determination by gas chromatography. Methane was detected by hydrogen flame ionization detector, and the quantitative relationship was determined by working curve of y=2041.2x+2187 with correlation coefficient of 0.9979. The relative standard deviation of 2.60-6.33% and the recovery rate of 96.36%∼105.89% were obtained during the parallel determination of standard gas. This method was not quite suitable for biogas content analysis because methane content in biogas would be over the measurement range in this method.

  6. Methods and systems for detecting gas flow by photoacoustic signal generation

    Science.gov (United States)

    Choudhury, Niloy; Challener, William Albert

    2018-03-06

    A method for the detection of a gas flowing from a location in a structure is described. A hollow-core optical fiber is placed in a position adjacent the structure. The fiber includes a sound-conductive cladding layer; and further includes at least one aperture extending into its cross-sectional diameter. A beam of pulsed, optical is transmitted into the fiber with a tunable laser. The optical energy is characterized by a wavelength that can be absorbed by the gas that flows into the fiber through the aperture. This causes a temperature fluctuation in the region of gas absorption, which in turn generates an acoustic wave in the absorption region. The acoustic wave travels through the cladding layer, and can be detected with a microphone, so as to provide the location of gas flow, based on the recorded position and movement of the acoustic wave. A related system is also described.

  7. Dangerous gas detection based on infrared video

    Science.gov (United States)

    Ding, Kang; Hong, Hanyu; Huang, Likun

    2018-03-01

    As the gas leak infrared imaging detection technology has significant advantages of high efficiency and remote imaging detection, in order to enhance the detail perception of observers and equivalently improve the detection limit, we propose a new type of gas leak infrared image detection method, which combines background difference methods and multi-frame interval difference method. Compared to the traditional frame methods, the multi-frame interval difference method we proposed can extract a more complete target image. By fusing the background difference image and the multi-frame interval difference image, we can accumulate the information of infrared target image of the gas leak in many aspect. The experiment demonstrate that the completeness of the gas leakage trace information is enhanced significantly, and the real-time detection effect can be achieved.

  8. New method of leak detecting in diagnostic of gas pipeline system

    International Nuclear Information System (INIS)

    Kalinowski, K.; Dabrowski, A.; Sobkiewicz, D.; Oracz, H.

    2007-01-01

    This report describes new directions in gas transmission pipelines diagnostics as well as new methods and equipment used to detect leaks. It was also shown that efficient and functional diagnostics system is the necessary condition to keep the exploitation of transmission systems safe. (author)

  9. Main Achievements 2003-2004 - Interdisciplinary Research - Radiation detection methods for health, earth and environmental sciences - Detection methods in gas chromatography

    International Nuclear Information System (INIS)

    2005-01-01

    Detection methods in gas chromatography are under development, especially ultra-sensitive gas chromatography detection methods to monitor the atmosphere (with respect to gases active in the destruction of the Earth ozone layer). A new chromatographic method has been elaborated for Ne determination, and technique for determination of Ar and N 2 in groundwater has been significantly improved. Measurements of neon are performed by means of a chromatographic system equipped with a helium ionization detector (PD-HID) doped with neon pulse discharge, working with a modified sample introduction system. The Ar and N 2 contents are determined by a thermal-conductivity detector (TCD). The problem of separation of Ar from O 2 has been solved by catalytic removal of the latter from the sample. The measurement reproducibility is 1%, 2% and 0.5% for Ar, Ne and N 2 , respectively. Both methods were successfully applied in measurements of groundwaters in the Cracow area. The excess air contents are in the range of about 1 to 3 cm 3 STP L-1. The values of recharge temperatures for Holocen water agree reasonably well with the yearly mean long-term surface air temperature (8.2 o C)

  10. Detection of irradiated fruits and vegetables by gas-chromatographic methods and electron spin-resonance

    Energy Technology Data Exchange (ETDEWEB)

    Farag, S.E.A. (National Centre for Radiation Research and Technology, Cairo (Egypt))

    1993-01-01

    Gas chromatographic methods detected some hydrocarbons esp. 17:1, 16:2, 15:0 and 14:1 in irradiated, Avocado, Papaya, Mangoes with 0.75, 1.5, 3.0 kGy and Apricot with 0.5 and 3.0 kGy. The detection of hydrocarbons was clearly at high doses but the low doses need more sensitive conditions using Liquid-Liquid-Gas chromatographic method as used here. Using Electron Spin-Resonance, produce a specific signal from irradiated onion (dried leaves) as well as apricot (hard coat of kernels) after some weeks of irradiation process but not clear with the other foodstuffs. (orig.)

  11. Distributed gas detection system and method

    Science.gov (United States)

    Challener, William Albert; Palit, Sabarni; Karp, Jason Harris; Kasten, Ansas Matthias; Choudhury, Niloy

    2017-11-21

    A distributed gas detection system includes one or more hollow core fibers disposed in different locations, one or more solid core fibers optically coupled with the one or more hollow core fibers and configured to receive light of one or more wavelengths from a light source, and an interrogator device configured to receive at least some of the light propagating through the one or more solid core fibers and the one or more hollow core fibers. The interrogator device is configured to identify a location of a presence of a gas-of-interest by examining absorption of at least one of the wavelengths of the light at least one of the hollow core fibers.

  12. Use of nonlocal helium microplasma for gas impurities detection by the collisional electron spectroscopy method

    Energy Technology Data Exchange (ETDEWEB)

    Kudryavtsev, Anatoly A., E-mail: akud@ak2138.spb.edu [St. Petersburg State University, 7-9 Universitetskaya nab., 199034 St. Petersburg (Russian Federation); Stefanova, Margarita S.; Pramatarov, Petko M. [Institute of Solid State Physics, Bulgarian Academy of Sciences, 72 Tzarigradsko Chaussee blvd., 1784 Sofia (Bulgaria)

    2015-10-15

    The collisional electron spectroscopy (CES) method, which lays the ground for a new field for analytical detection of gas impurities at high pressures, has been verified. The CES method enables the identification of gas impurities in the collisional mode of electron movement, where the advantages of nonlocal formation of the electron energy distribution function (EEDF) are fulfilled. Important features of dc negative glow microplasma and probe method for plasma diagnostics are applied. A new microplasma gas analyzer design is proposed. Admixtures of 0.2% Ar, 0.6% Kr, 0.1% N{sub 2}, and 0.05% CO{sub 2} are used as examples of atomic and molecular impurities to prove the possibility for detecting and identifying their presence in high pressure He plasma (50–250 Torr). The identification of the particles under analysis is made from the measurements of the high energy part of the EEDF, where maxima appear, resulting from the characteristic electrons released in Penning reactions of He metastable atoms with impurity particles. Considerable progress in the development of a novel miniature gas analyzer for chemical sensing in gas phase environments has been made.

  13. Development of a real-time absorption method for detecting the mercaptan odorizing mixture of natural gas

    NARCIS (Netherlands)

    Kireev, SV; Petrov, NG; Podolyako, EM; Shnyrev, SL

    The absorption of mercaptan mixtures used for odorizing natural gas and mixtures of natural gas is experimentally studied in the spectral range 2.5-20 mu m. An absorption method for the real-time detection of the odorant concentration is proposed. The method is based on intensity measurements of the

  14. Corrective actions to gas accumulation in safety injection system pipings of PWRs and gas void detection method

    International Nuclear Information System (INIS)

    Maki, Nobuo

    2000-01-01

    In the US, gas accumulation events of safety injection systems of PWRs during plant operation are continuously reported. As the events may result in loss of safety function, the USNRC is alerting licensees by Information Notices. The cause of the events is coolant leakage to interfacing systems with lower pressure, or gas dissolution of primary coolant by partial pressure drop. In this study, it was clarified by the evaluation of the cause of the events of US plants, gas accumulation in piping between an accumulator and Residual Heat Removal System should be quantitatively investigated regarding Japanese plants. Also, effectiveness of ultrasonic testing which is used for monthly gas accumulation surveillance in US plants was demonstrated using a model loop. In addition, the method was confirmed applicable by an experiment carried out at INSS to detect cavitation voids in piping systems. (author)

  15. Hierarchical Leak Detection and Localization Method in Natural Gas Pipeline Monitoring Sensor Networks

    OpenAIRE

    Ning Yu; Renjian Feng; Jiangwen Wan; Yinfeng Wu; Yang Yu

    2011-01-01

    In light of the problems of low recognition efficiency, high false rates and poor localization accuracy in traditional pipeline security detection technology, this paper proposes a type of hierarchical leak detection and localization method for use in natural gas pipeline monitoring sensor networks. In the signal preprocessing phase, original monitoring signals are dealt with by wavelet transform technology to extract the single mode signals as well as characteristic parameters. In the initia...

  16. Field Tests of the Magnetotelluric Method to Detect Gas Hydrates, Mallik, Mackenzie Delta, Canada

    Science.gov (United States)

    Craven, J. A.; Roberts, B.; Bellefleur, G.; Spratt, J.; Wright, F.; Dallimore, S. R.

    2008-12-01

    The magnetotelluric method is not generally utilized at extreme latitudes due primarily to difficulties in making the good electrical contact with the ground required to measure the electric field. As such, the magnetotelluric technique has not been previously investigated to direct detect gas hydrates in on-shore permafrost environments. We present the results of preliminary field tests at Mallik, Northwest Territories, Canada, that demonstrate good quality magnetotelluric data can be obtained in this environment using specialized electrodes and buffer amplifiers similar to those utilized by Wannamaker et al (2004). This result suggests that subsurface images from larger magnetotelluric surveys will be useful to complement other techniques to detect, quantify and characterize gas hydrates.

  17. The gas filled separator as a separation method to detect transuranic elements

    International Nuclear Information System (INIS)

    Ninov, V.

    1992-08-01

    The mass spectrometer NASE (NAchSEparator) built as a post-separator and located behind the velocity filter SHIP at the GSI in Darmstadt, was taken into operation as a gas-filled separator, and its separation properties for fusion products from heavy ion reactions were studied. Chapter 2 describes the principle of separation in a gas-filled magnet. The technical specifications of the separator, the detectors and the setup of detection electronics are outlined in chapter 3. The studies of separation properties are described in chapter 4, and chapter 5 deals with preliminary applications of the gas-filled separator to detect isotopes poor in neutrons, with an atomic number Z = 92, 93. Chapter 6 is concerned with preliminary tests to detect heavy nuclei with an atomic number Z > = 100 by means of light radiation and actinide targets. The experimental results of comparative measurements between the velocity filter SHIP and the gas-filled separator are pointed out in chapter 7, and future application possibilities of gas-filled separators for synthesis of heaviest nuclei through asymmetric reactions are discussed. (orig./BBR) [de

  18. Gas detection system

    International Nuclear Information System (INIS)

    Allan, C.J.; Bayly, J.G.

    1975-01-01

    The gas detection system provides for the effective detection of gas leaks over a large area. It includes a laser which has a laser line corresponding to an absorption line of the gas to be detected. A He-Xe laser scans a number of retroreflectors which are strategically located around a D 2 O plant to detect H 2 S leaks. The reflected beam is focused by a telescope, filtered, and passed into an infrared detector. The laser may be made to emit two frequencies, one of which corresponds with an H 2 S absorption line; or it may be modulated on and off the H 2 S absorption line. The relative amplitude of the absorbed light will be a measure of the H 2 S present

  19. A new method for ultrasound detection of interfacial position in gas-liquid two-phase flow.

    Science.gov (United States)

    Coutinho, Fábio Rizental; Ofuchi, César Yutaka; de Arruda, Lúcia Valéria Ramos; Neves, Flávio; Morales, Rigoberto E M

    2014-05-22

    Ultrasonic measurement techniques for velocity estimation are currently widely used in fluid flow studies and applications. An accurate determination of interfacial position in gas-liquid two-phase flows is still an open problem. The quality of this information directly reflects on the accuracy of void fraction measurement, and it provides a means of discriminating velocity information of both phases. The algorithm known as Velocity Matched Spectrum (VM Spectrum) is a velocity estimator that stands out from other methods by returning a spectrum of velocities for each interrogated volume sample. Interface detection of free-rising bubbles in quiescent liquid presents some difficulties for interface detection due to abrupt changes in interface inclination. In this work a method based on velocity spectrum curve shape is used to generate a spatial-temporal mapping, which, after spatial filtering, yields an accurate contour of the air-water interface. It is shown that the proposed technique yields a RMS error between 1.71 and 3.39 and a probability of detection failure and false detection between 0.89% and 11.9% in determining the spatial-temporal gas-liquid interface position in the flow of free rising bubbles in stagnant liquid. This result is valid for both free path and with transducer emitting through a metallic plate or a Plexiglas pipe.

  20. Method of controlling weld chamber purge and cover gas atmosphere

    International Nuclear Information System (INIS)

    Yeo, D.

    1992-01-01

    A method of controlling the gas atmosphere in a welding chamber includes detecting the absence of a fuel rod from the welding chamber and, in response thereto, initiating the supplying of a flow of argon gas to the chamber to purge air therefrom. Further, the method includes detecting the entry of a fuel rod in the welding chamber and, in response thereto, terminating the supplying of the flow of argon gas to the chamber and initiating the supplying of a flow of helium gas to the chamber to purge argon gas therefrom and displace the argon gas in the chamber. Also, the method includes detecting the withdrawal of the fuel rod from the welding chamber and, in response thereto, terminating the supplying of the flow of helium gas to the chamber and initiating the supplying of argon to the chamber to purge the air therefrom. The method also includes detecting the initiation of a weld cycle and, in response thereto, momentarily supplying a flow of argon gas to the welding electrode tip for initiating the welding arc. (Author)

  1. Gas Leak Detection by Dilution of Atmospheric Oxygen

    Directory of Open Access Journals (Sweden)

    Armin Lambrecht

    2017-12-01

    Full Text Available Gas leak detection is an important issue in infrastructure monitoring and industrial production. In this context, infrared (IR absorption spectroscopy is a major measurement method. It can be applied in an extractive or remote detection scheme. Tunable laser spectroscopy (TLS instruments are able to detect CH4 leaks with column densities below 10 ppm·m from a distance of 30 m in less than a second. However, leak detection of non-IR absorbing gases such as N2 is not possible in this manner. Due to the fact that any leaking gas displaces or dilutes the surrounding background gas, an indirect detection is still possible. It is shown by sensitive TLS measurements of the ambient background concentration of O2 that N2 leaks can be localized with extractive and standoff methods for distances below 1 m. Minimum leak rates of 0.1 mbar·L/s were determined. Flow simulations confirm that the leakage gas typically effuses in a narrow jet. The sensitivity is mainly determined by ambient flow conditions. Compared to TLS detection of CH4 at 1651 nm, the indirect method using O2 at 761 nm is experimentally found to be less sensitive by a factor of 100. However, the well-established TLS of O2 may become a universal tool for rapid leakage screening of vessels that contain unknown or inexpensive gases, such as N2.

  2. Experimental study on a de-noising system for gas and oil pipelines based on an acoustic leak detection and location method

    International Nuclear Information System (INIS)

    Liu, Cuiwei; Li, Yuxing; Fang, Liping; Xu, Minghai

    2017-01-01

    To protect the pipelines from significant danger, the acoustic leak detection and location method for oil and gas pipelines is studied, and a de-noising system is established to extract leakage characteristics from signals. A test loop for gas and oil is established to carry out experiments. First, according to the measured signals, fitting leakage signals are obtained, and then, the objective signals are constructed by adding noises to the fitting signals. Based on the proposed evaluation indexes, the filtering methods are then applied to process the constructed signals and the de-noising system is established. The established leakage extraction system is validated and then applied to process signals measured in gas pipelines that include a straight pipe, elbow pipe and reducing pipe. The leak detection and location is carried out effectively. Finally, the system is applied to process signals measured in water pipelines. The results demonstrate that the proposed de-noising system is effective at extracting leakage signals from measured signals and that the proposed leak detection and location method has a higher detection sensitivity and localization accuracy. For a pipeline with an inner diameter of 42 mm, the smallest leakage orifice that can be detected is 0.1 mm for gas and water and the largest location error is 0.874% for gas and 0.176% for water. - Highlights: • Three evaluation indexes are proposed: SNR, RMSE and ALPD. • The de-noising system is established in the gas and oil pipelines. • The established system is used for gas pipeline effectively, including interference pipes. • The established de-noising system is used for water pipeline effectively.

  3. Hierarchical Leak Detection and Localization Method in Natural Gas Pipeline Monitoring Sensor Networks

    Science.gov (United States)

    Wan, Jiangwen; Yu, Yang; Wu, Yinfeng; Feng, Renjian; Yu, Ning

    2012-01-01

    In light of the problems of low recognition efficiency, high false rates and poor localization accuracy in traditional pipeline security detection technology, this paper proposes a type of hierarchical leak detection and localization method for use in natural gas pipeline monitoring sensor networks. In the signal preprocessing phase, original monitoring signals are dealt with by wavelet transform technology to extract the single mode signals as well as characteristic parameters. In the initial recognition phase, a multi-classifier model based on SVM is constructed and characteristic parameters are sent as input vectors to the multi-classifier for initial recognition. In the final decision phase, an improved evidence combination rule is designed to integrate initial recognition results for final decisions. Furthermore, a weighted average localization algorithm based on time difference of arrival is introduced for determining the leak point’s position. Experimental results illustrate that this hierarchical pipeline leak detection and localization method could effectively improve the accuracy of the leak point localization and reduce the undetected rate as well as false alarm rate. PMID:22368464

  4. Hierarchical leak detection and localization method in natural gas pipeline monitoring sensor networks.

    Science.gov (United States)

    Wan, Jiangwen; Yu, Yang; Wu, Yinfeng; Feng, Renjian; Yu, Ning

    2012-01-01

    In light of the problems of low recognition efficiency, high false rates and poor localization accuracy in traditional pipeline security detection technology, this paper proposes a type of hierarchical leak detection and localization method for use in natural gas pipeline monitoring sensor networks. In the signal preprocessing phase, original monitoring signals are dealt with by wavelet transform technology to extract the single mode signals as well as characteristic parameters. In the initial recognition phase, a multi-classifier model based on SVM is constructed and characteristic parameters are sent as input vectors to the multi-classifier for initial recognition. In the final decision phase, an improved evidence combination rule is designed to integrate initial recognition results for final decisions. Furthermore, a weighted average localization algorithm based on time difference of arrival is introduced for determining the leak point's position. Experimental results illustrate that this hierarchical pipeline leak detection and localization method could effectively improve the accuracy of the leak point localization and reduce the undetected rate as well as false alarm rate.

  5. Hierarchical Leak Detection and Localization Method in Natural Gas Pipeline Monitoring Sensor Networks

    Directory of Open Access Journals (Sweden)

    Ning Yu

    2011-12-01

    Full Text Available In light of the problems of low recognition efficiency, high false rates and poor localization accuracy in traditional pipeline security detection technology, this paper proposes a type of hierarchical leak detection and localization method for use in natural gas pipeline monitoring sensor networks. In the signal preprocessing phase, original monitoring signals are dealt with by wavelet transform technology to extract the single mode signals as well as characteristic parameters. In the initial recognition phase, a multi-classifier model based on SVM is constructed and characteristic parameters are sent as input vectors to the multi-classifier for initial recognition. In the final decision phase, an improved evidence combination rule is designed to integrate initial recognition results for final decisions. Furthermore, a weighted average localization algorithm based on time difference of arrival is introduced for determining the leak point’s position. Experimental results illustrate that this hierarchical pipeline leak detection and localization method could effectively improve the accuracy of the leak point localization and reduce the undetected rate as well as false alarm rate.

  6. Detection methods for atoms and radicals in the gas phase

    Science.gov (United States)

    Hack, W.

    This report lists atoms and free radicals in the gas phase which are of interest for environmental and flame chemistry and have been detected directly. The detection methods which have been used are discussed with respect to their range of application, specificity and sensitivity. In table 1, detection methods for the five atoms of group IV (C, Si, Ge, Sn, Pb) and about 60 radicals containing at least one atom of group IV are summarized (CH, Cd, Cf, CC1, CBr, Cn, Cs, CSe, CH2, CD2, Chf, Cdf, CHC1, CHBr, CF2, CC12, CBr2, CFC1, CFBr, CH3, CD3, CF3, CH2F, CH2C1, CH2Br, CHF2, CHC12, CHBr2, Hco, Fco, CH30, CD30, CH2OH, CH3S, Nco, CH4N, CH302, CF302; C2, C2N, C2H, C20, C2HO, C2H3, C2F3, C2H5, C2HsO, C2H4OH, CH3CO, CD3CO, C2H3O, C2H502, CH3COO2, C2H4N, C2H6N, C3; Si, SiF, SiF2, SiO, SiC, Si2; Ge, GeC, GeO, GeF, GeF2, GeCl2, Sn, SnF, SnO, SnF2, Pb, PbF, PbF2, PbO, PbS). In table 2 detection methods for about 25 other atoms and 60 radicals are listed: (H, D, O, O2, Oh, Od, HO2, DO2, F, Ci, Br, I, Fo, Cio, BrO, Io, FO2, C1O2, Li, Na, K, Rb, Cs, N, N3, Nh, Nd, Nf, Nci, NBr, NH2, ND2, Nhd, Nhf, NF2, NC12, N2H3, No, NO2, NO3, Hno, Dno, P, Ph, Pd, Pf, Pci, PH2, PD2, PF2, Po, As, AsO, AsS, Sb, Bi, S, S2, Sh, Sd, Sf, SF2, So, Hso, Dso, Sn, Se, Te, Se2, SeH, SeD, SeF, SeO, SeS, SeN, TeH, TeO, Bh, BH2, Bo, Bn, B02, Cd, Hg, UF5). The tables also cite some recent kinetic applications of the various methods.

  7. Novel Methods of Hydrogen Leak Detection

    International Nuclear Information System (INIS)

    Pushpinder S Puri

    2006-01-01

    For hydrogen to become a consumer fuel for automotive and domestic power generation, safety is paramount. Today's hydrogen systems are built with inherent safety measures and multiple levels of protection. However, human senses, in particular, the sense of smell, is considered the ultimate safeguards against leaks. Since hydrogen is an odorless gas, use of odorants to detect leaks, as is done in case of natural gas, is obvious solution. The odorants required for hydrogen used in fuel cells have a unique requirement which must be met. This is because almost all of the commercial odorants used in gas leak detection contain sulfur which acts as poison for the catalysts used in hydrogen based fuel cells, most specifically for the PEM (polymer electrolyte membrane or proton exchange membrane) fuel cells. A possible solution to this problem is to use non-sulfur containing odorants. Chemical compounds based on mixtures of acrylic acid and nitrogen compounds have been adopted to achieve a sulfur-free odorization of a gas. It is, therefore, desired to have a method and system for hydrogen leak detection using odorant which can incorporate a uniform concentration of odorant in the hydrogen gas, when odorants are mixed in the hydrogen storage or delivery means. It is also desired to develop methods where the odorant is not added to the bulk hydrogen, keeping it free of the odorization additives. A series of novel solutions are proposed which address the issues raised above. These solutions are divided into three categories as follows: 1. Methods incorporating an odorant in the path of hydrogen leak as opposed to adding it to the hydrogen gas. 2. Methods where odorants are generated in-situ by chemical reaction with the leaking hydrogen 3. Methods of dispensing and storing odorants in high pressure hydrogen gas which release odorants to the gas at a uniform and predetermined rates. Use of one or more of the methods described here in conjunction with appropriate engineering

  8. Methods for Gas Sensing with Single-Walled Carbon Nanotubes

    Science.gov (United States)

    Kaul, Anupama B. (Inventor)

    2013-01-01

    Methods for gas sensing with single-walled carbon nanotubes are described. The methods comprise biasing at least one carbon nanotube and exposing to a gas environment to detect variation in temperature as an electrical response.

  9. Development of the Raman lidar system for remote hydrogen gas detection

    Energy Technology Data Exchange (ETDEWEB)

    Choi, In Young; Baik, Sung Hoon; Park, Seung Kyu; Park, Nak Gyu; Choi, Young Soo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Detection of hydrogen (H{sub 2}) gas leakage is very important for safety of the nuclear power plant because H{sub 2} gas is very flammable and explosive. H{sub 2} gas is generated by oxidizing the nuclear fuel cladding during the critical accident and generated H{sub 2} gas leads to serious secondary damages in the containment building of nuclear power plant. Thus, various H{sub 2} gas detection techniques are used in the nuclear power plant such as catalytic combustion sensors, semiconducting oxide sensors, thermal conductivity sensors and electrochemical sensor. A Raman lidar (Light Detection And Ranging) system for remote detection of the H{sub 2} gas can cover the area in the containment building of a nuclear power plant. H{sub 2} gas has a very strong Raman Effect, and H{sub 2} Raman cells have been widely used for laser wavelength conversion. In this study, Raman lidar system was developed for H{sub 2} gas detection used in the containment building of nuclear power plant. In this study, remote hydrogen gas detection devices and measuring algorithm are developed by using the Raman lidar method. Through the experiment, we proved that our developed Raman lidar system was possible to measure the N{sub 2} and H{sub 2} gas scattering signal remotely.

  10. Two-phase xenon detector with gas amplification and electroluminescent signal detection

    International Nuclear Information System (INIS)

    Akimov, D.Yu.; Burenkov, A.A.; Grishkin, Yu.L.; Kovalenko, A.G.; Lebedenko, V.N.; Stekhanov, V.N.

    2008-01-01

    An optical technique for detecting ionization electrons produced during ionization of the liquid phase has been experimentally tested in two-phase (liquid-gas) xenon. The effects of gas and electroluminescent amplifications at the wire anode are simultaneously used for detection. This method allows construction of a supersensitive detector of small ionization signals-down to those corresponding to the detection of single electrons [ru

  11. Novel Methods of Hydrogen Leak Detection

    International Nuclear Information System (INIS)

    Pushpinder S Puri

    2006-01-01

    With the advent of the fuel cell technology and a drive for clean fuel, hydrogen gas is emerging as a leading candidate for the fuel of choice. For hydrogen to become a consumer fuel for automotive and domestic power generation, safety is paramount. It is, therefore, desired to have a method and system for hydrogen leak detection using odorant which can incorporate a uniform concentration of odorant in the hydrogen gas, when odorants are mixed in the hydrogen storage or delivery means. It is also desired to develop methods where the odorant is not added to the bulk hydrogen, keeping it free of the odorization additives. When odorants are not added to the hydrogen gas in the storage or delivery means, methods must be developed to incorporate odorant in the leaking gas so that leaks can be detected by small. Further, when odorants are not added to the stored hydrogen, it may also be desirable to observe leaks by sight by discoloration of the surface of the storage or transportation vessels. A series of novel solutions are proposed which address the issues raised above. These solutions are divided into three categories as follows: 1. Methods incorporating an odorant in the path of hydrogen leak as opposed to adding it to the hydrogen gas. 2. Methods where odorants are generated in-situ by chemical reaction with the leaking hydrogen 3. Methods of dispensing and storing odorants in high pressure hydrogen gas which release odorants to the gas at a uniform and predetermined rates. Use of one or more of the methods described here in conjunction with appropriate engineering solutions will assure the ultimate safety of hydrogen use as a commercial fuel. (authors)

  12. Detection of gas atoms with carbon nanotubes

    Science.gov (United States)

    Arash, B.; Wang, Q.

    2013-01-01

    Owning to their unparalleled sensitivity resolution, nanomechanical resonators have excellent capabilities in design of nano-sensors for gas detection. The current challenge is to develop new designs of the resonators for differentiating distinct gas atoms with a recognizably high sensitivity. In this work, the characteristics of impulse wave propagation in carbon nanotube-based sensors are investigated using molecular dynamics simulations to provide a new method for detection of noble gases. A sensitivity index based on wave velocity shifts in a single-walled carbon nanotube, induced by surrounding gas atoms, is defined to explore the efficiency of the nano-sensor. The simulation results indicate that the nano-sensor is able to differentiate distinct noble gases at the same environmental temperature and pressure. The inertia and the strengthening effects by the gases on wave characteristics of carbon nanotubes are particularly discussed, and a continuum mechanics shell model is developed to interpret the effects.

  13. Sulphur hexafluoride gas detection

    CSIR Research Space (South Africa)

    Stolper, R

    2006-02-01

    Full Text Available This poster describes the development process of an electro-optical based solution for detecting and locating SF6 gas leaks at gas insulated switch gear. The principal technologies that were researched are explained with their advantages...

  14. Detection blockages and valve statues in natural gas pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Dawson, Karl; Short, Gordon; Wang, Xuesong [Pipeline Engineering Ltd, North Yorkshire, (United Kingdom); Lennox, Barry; Lewis, Keith; Turner, John [University of Manchester, Manchester, (United Kingdom); Lewis, Chris [BP exploration, Aberdeen, (United Kingdom)

    2010-07-01

    Detecting features in pipelines containing flowing gas is difficult. This paper investigated a patented acoustic reflectometry technique for detecting defects in gas pipelines. The basic concept of this technique is to inject a pulse of sound into a pipeline and then measure the reflections produced while the signal travels along the length of the pipe. A modification in the internal section of the pipe will produce a reflection which, given with the speed of sound in the gas within the pipeline, provides the location of the feature. Laboratory tests on a 16m rigid PVC pipe and two field trials were undertaken to test this new method. The results showed that acoustic reflectometry can be used to identify features resulting from blockages and leakages. The field tests demonstrated that the method is capable of surveying both small and large diameter pipelines with lengths up to 10 km.

  15. State of the art of technologies for remote detection of natural gas

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-06-01

    There is an increasing awareness of the need to detect and survey gaseous fugitive emissions from production and distribution systems, industrial and energy processes, transportation systems for dangerous goods, leaks from landfill bodies,and from natural sources. Leaks may influence the function of production and distribution systems, or may be hazardous to human life or environment. It is important to be able to detect the leak source of gases,survey and quantify gaseous and fugitive emissions, and to visualise and map the spatial distribution of the gas plume. Most gases are not detectable by human sensor systems, and traditional surveying techniques and methods have poor accuracy, are labour intensive, and are normally not cost-efficient. Modern remote sensing techniques like high resolution thermography and powerful laser systems have opened up new possibilities to develop accurate, stable and cost-efficient handhold, land- mobile and airborne gas detection systems for a wide variety of applications. During the last decade research activities of remote gas detection have been performed in different high tech industrial countries round the world in order to meet the requests for remote gas detection technologies expressed by different civilian and military end users. In April 1996 a first meeting of a group of international researchers and end users was hold in Orlando, USA, in order to discuss the interest and the possibilities using passive and active remote sensing technologies for remote gas detection. The consensus of this meeting was that there is a need for highly sensitive and flexible remote gas detection techniques for detection of leaks from different gas sources, with ability to detect leak plumes at a sensitivity from 1-5 ppm and upwards, at an operating range from a few meters up to 500 m (1500 feet) or more, and with a geometric resolution from 1 mm{sup 2} for small scale surveying, up to 10-100 mm{sup 2} for large scale surveying. Furthermore

  16. Detection device for off-gas system accidents

    International Nuclear Information System (INIS)

    Kubota, Ryuji; Tsuruoka, Ryozo; Yamanari, Shozo.

    1984-01-01

    Purpose: To rapidly isolate the off-gas system by detecting the off-gas system failure accident in a short time. Constitution: Radiation monitors are disposed to ducts connecting an exhaust gas area and an air conditioning system as a portion of a turbine building. The ducts are disposed independently such that they ventilate only the atmosphere in the exhaust gas area and do not mix the atmosphere in the turbine building. Since radioactivity issued upon off-gas accidents to the exhaust gas area is sucked to the duct, it can be detected by radiation detection monitors in a short time after the accident. Further, since the operator judges it as the off-gas system accident, the off-gas system can be isolated in a short time after the accident. (Moriyama, K.)

  17. Low-Cost Resonant Cavity Raman Gas Probe for Multi-Gas Detection

    Science.gov (United States)

    Thorstensen, J.; Haugholt, K. H.; Ferber, A.; Bakke, K. A. H.; Tschudi, J.

    2014-12-01

    Raman based gas sensing can be attractive in several industrial applications, due to its multi-gas sensing capabilities and its ability to detect O_2 and N_2. In this article, we have built a Raman gas probe, based on low-cost components, which has shown an estimated detection limit of 0.5 % for 30 second measurements of N_2 and O_2. While this detection limit is higher than that of commercially available equipment, our estimated component cost is approximately one tenth of the price of commercially available equipment. The use of a resonant Fabry-Pérot cavity increases the scattered signal, and hence the sensitivity, by a factor of 50. The cavity is kept in resonance using a piezo-actuated mirror and a photodiode in a feedback loop. The system described in this article was made with minimum-cost components to demonstrate the low-cost principle. However, it is possible to decrease the detection limit using a higher-powered (but still low-cost) laser and improving the collection optics. By applying these improvements, the detection limit and estimated measurement precision will be sufficient for e.g. the monitoring of input gases in combustion processes, such as e.g. (bio-)gas power plants. In these processes, knowledge about gas compositions with 0.1 % (absolute) precision can help regulate and optimize process conditions. The system has the potential to provide a low-cost, industrial Raman sensor that is optimized for specific gas-detection applications.

  18. Nanoparticle-based gas sensors and methods of using the same

    Science.gov (United States)

    Mickelson, William; Zettl, Alex

    2017-10-17

    Gas sensors are provided. The gas sensors include a gas sensing element having metal oxide nanoparticles and a thin-film heating element. Systems that include the gas sensors, as well as methods of using the gas sensors, are also provided. Embodiments of the present disclosure find use in a variety of different applications, including detecting whether an analyte is present in a gaseous sample.

  19. 46 CFR 154.1350 - Flammable gas detection system.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Flammable gas detection system. 154.1350 Section 154... Equipment Instrumentation § 154.1350 Flammable gas detection system. (a) The vessel must have a fixed flammable gas detection system that has sampling points in: (1) Each cargo pump room; (2) Each cargo...

  20. [Gas pipeline leak detection based on tunable diode laser absorption spectroscopy].

    Science.gov (United States)

    Zhang, Qi-Xing; Wang, Jin-Jun; Liu, Bing-Hai; Cai, Ting-Li; Qiao, Li-Feng; Zhang, Yong-Ming

    2009-08-01

    The principle of tunable diode laser absorption spectroscopy and harmonic detection technique was introduced. An experimental device was developed by point sampling through small multi-reflection gas cell. A specific line near 1 653. 7 nm was targeted for methane measurement using a distributed feedback diode laser as tunable light source. The linearity between the intensity of second harmonic signal and the concentration of methane was determined. The background content of methane in air was measured. The results show that gas sensors using tunable diode lasers provide a high sensitivity and high selectivity method for city gas pipeline leak detection.

  1. Fault Detection Using the Clustering-kNN Rule for Gas Sensor Arrays

    Directory of Open Access Journals (Sweden)

    Jingli Yang

    2016-12-01

    Full Text Available The k-nearest neighbour (kNN rule, which naturally handles the possible non-linearity of data, is introduced to solve the fault detection problem of gas sensor arrays. In traditional fault detection methods based on the kNN rule, the detection process of each new test sample involves all samples in the entire training sample set. Therefore, these methods can be computation intensive in monitoring processes with a large volume of variables and training samples and may be impossible for real-time monitoring. To address this problem, a novel clustering-kNN rule is presented. The landmark-based spectral clustering (LSC algorithm, which has low computational complexity, is employed to divide the entire training sample set into several clusters. Further, the kNN rule is only conducted in the cluster that is nearest to the test sample; thus, the efficiency of the fault detection methods can be enhanced by reducing the number of training samples involved in the detection process of each test sample. The performance of the proposed clustering-kNN rule is fully verified in numerical simulations with both linear and non-linear models and a real gas sensor array experimental system with different kinds of faults. The results of simulations and experiments demonstrate that the clustering-kNN rule can greatly enhance both the accuracy and efficiency of fault detection methods and provide an excellent solution to reliable and real-time monitoring of gas sensor arrays.

  2. Fault Detection Using the Clustering-kNN Rule for Gas Sensor Arrays

    Science.gov (United States)

    Yang, Jingli; Sun, Zhen; Chen, Yinsheng

    2016-01-01

    The k-nearest neighbour (kNN) rule, which naturally handles the possible non-linearity of data, is introduced to solve the fault detection problem of gas sensor arrays. In traditional fault detection methods based on the kNN rule, the detection process of each new test sample involves all samples in the entire training sample set. Therefore, these methods can be computation intensive in monitoring processes with a large volume of variables and training samples and may be impossible for real-time monitoring. To address this problem, a novel clustering-kNN rule is presented. The landmark-based spectral clustering (LSC) algorithm, which has low computational complexity, is employed to divide the entire training sample set into several clusters. Further, the kNN rule is only conducted in the cluster that is nearest to the test sample; thus, the efficiency of the fault detection methods can be enhanced by reducing the number of training samples involved in the detection process of each test sample. The performance of the proposed clustering-kNN rule is fully verified in numerical simulations with both linear and non-linear models and a real gas sensor array experimental system with different kinds of faults. The results of simulations and experiments demonstrate that the clustering-kNN rule can greatly enhance both the accuracy and efficiency of fault detection methods and provide an excellent solution to reliable and real-time monitoring of gas sensor arrays. PMID:27929412

  3. Gas Detection Instrument Based on Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    ANSONG FENG

    2013-06-01

    Full Text Available The wireless sensor network is used to simulate poisonous gas generating system in the Fire-Fighting Simulated Training System. In the paper, we use the wireless signal to simulate the poisonous gas source and use received signal strength indicator (RSSI to simulate the distance between the fireman and the gas source. The gas detection instrument samples the temperature and sphygmus of the trainee and uses the wireless signal as poisonous gas signal. When the trainee enters into the poisonous gas area, the gas detection instrument warns with sound and light and sends the type, density value, the location of the poisonous gas and vital signs of the trainee to host. The paper discusses the software and hardware design of the gas detection instrument. The system has been used to the several of Fire-Fighting training systems.

  4. On camera-based smoke and gas leakage detection

    Energy Technology Data Exchange (ETDEWEB)

    Nyboe, Hans Olav

    1999-07-01

    Gas detectors are found in almost every part of industry and in many homes as well. An offshore oil or gas platform may host several hundred gas detectors. The ability of the common point and open path gas detectors to detect leakages depends on their location relative to the location of a gas cloud. This thesis describes the development of a passive volume gas detector, that is, one than will detect a leakage anywhere in the area monitored. After the consideration of several detection techniques it was decided to use an ordinary monochrome camera as sensor. Because a gas leakage may perturb the index of refraction, parts of the background appear to be displaced from their true positions, and it is necessary to develop algorithms that can deal with small differences between images. The thesis develops two such algorithms. Many image regions can be defined and several feature values can be computed for each region. The value of the features depends on the pattern in the image regions. The classes studied in this work are: reference, gas, smoke and human activity. Test show that observation belonging to these classes can be classified fairly high accuracy. The features in the feature set were chosen and developed for this particular application. Basically, the features measure the magnitude of pixel differences, size of detected phenomena and image distortion. Interesting results from many experiments are presented. Most important, the experiments show that apparent motion caused by a gas leakage or heat convection can be detected by means of a monochrome camera. Small leakages of methane can be detected at a range of about four metres. Other gases, such as butane, where the densities differ more from the density of air than the density of methane does, can be detected further from the camera. Gas leakages large enough to cause condensation have been detected at a camera distance of 20 metres. 59 refs., 42 figs., 13 tabs.

  5. An Atmosphere-based Method for Detection and Quantification of Methane Emisions from Natural Gas Infrastructure in an Urban Environment

    Science.gov (United States)

    McKain, K.; Down, A.; Raciti, S. M.; Budney, J.; Hutyra, L.; Floerchinger, C. R.; Herndon, S. C.; Nehrkorn, T.; Zahniser, M. S.; Sargent, M. R.; Jackson, R. B.; Phillips, N. G.; Wofsy, S. C.

    2015-12-01

    Methane emissions from the natural gas supply-chain are highly uncertain and can vary widely among components and processes. We present an atmosphere-based method for detecting and quantifying the area and time-averaged surface flux of methane from natural gas infrastructure, and its application to the case-study of Boston, Massachusetts. Continuous measurements of atmospheric methane at a network of stations, inside and outside the city, are used to quantify the atmospheric methane gradient due to emissions from the urban area. Simultaneous observations of atmospheric ethane, and data on the ethane and methane content of the pipeline gas flowing through the region, are used to trace the atmospheric methane enhancement to the natural gas source. An atmospheric transport model is used to quantitatively relate the observed methane enhancement to a surface flux from the whole urban region. We find that methane emissions from natural gas in the urban region over one year was equal to 2.7 ± 0.6 % of the natural gas delivered to the region. Our findings for Boston suggest natural-gas-consuming regions, generally, may be larger sources of methane to the atmosphere than is current estimated and represent areas of significant resource loss.

  6. Signal-based Gas Leakage Detection for Fluid Power Accumulators in Wind Turbines

    DEFF Research Database (Denmark)

    Liniger, Jesper; Sepehri, Nariman; N. Soltani, Mohsen

    2017-01-01

    This paper describes the development and application of a signal-based fault detection method for identifying gas leakage in hydraulic accumulators used in wind turbines. The method uses Multiresolution Signal Decomposition (MSD) based on wavelets for feature extraction from a~single fluid pressure...... measurement located close to the accumulator. Gas leakage is shown to create increased variations in this pressure signal. The Root Mean Square (RMS) of the detail coefficient Level 9 from the MSD is found as the most sensitive and robust fault indicator of gas leakage. The method is verified...... on an experimental setup allowing for the replication of the conditions for accumulators in wind turbines. Robustness is tested in a multi-fault environment where gas and external fluid leakage occurs simultaneously. In total, 24 experiments are performed, which show that the method is sensitive to gas leakage...

  7. Method of detecting irradiated pepper

    International Nuclear Information System (INIS)

    Doumaru, Takaaki; Furuta, Masakazu; Katayama, Tadashi; Toratani, Hirokazu; Takeda, Atsuhiko

    1989-01-01

    Spices represented by pepper are generally contaminated by microorganisms, and for using them as foodstuffs, some sterilizing treatment is indispensable. However, heating is not suitable to spices, accordingly ethylene oxide gas sterilization has been inevitably carried out, but its carcinogenic property is a problem. Food irradiation is the technology for killing microorganisms and noxious insects which cause the rotting and spoiling of foods and preventing the germination, which is an energy-conserving method without the fear of residual chemicals, therefore, it is most suitable to the sterilization of spices. In the irradiation of lower than 10 kGy, the toxicity test is not required for any food, and the irradiation of spices is permitted in 20 countries. However, in order to establish the international distribution organization for irradiated foods, the PR to consumers and the development of the means of detecting irradiation are the important subjects. The authors used pepper, and examined whether the hydrogen generated by irradiation remains in seeds and it can be detected or not. The experimental method and the results are reported. From the samples without irradiation, hydrogen was scarcely detected. The quantity of hydrogen generated was proportional to dose. The measuring instrument is only a gas chromatograph. (K.I.)

  8. Detection of gas leakage

    Science.gov (United States)

    Thornberg, Steven [Peralta, NM; Brown, Jason [Albuquerque, NM

    2012-06-19

    A method of detecting leaks and measuring volumes as well as an apparatus, the Power-free Pump Module (PPM), that is a self-contained leak test and volume measurement apparatus that requires no external sources of electrical power during leak testing or volume measurement, where the invention is a portable, pneumatically-controlled instrument capable of generating a vacuum, calibrating volumes, and performing quantitative leak tests on a closed test system or device, all without the use of alternating current (AC) power. Capabilities include the ability is to provide a modest vacuum (less than 10 Torr), perform a pressure rise leak test, measure the gas's absolute pressure, and perform volume measurements. All operations are performed through a simple rotary control valve which controls pneumatically-operated manifold valves.

  9. Detection of Volatile Organic Compound Gas Using Localized Surface Plasmon Resonance of Gold Nanoparticles

    International Nuclear Information System (INIS)

    Sri Nengsih; Akrajas Ali Umar; Muhamad Mat Salleh; Muhammad Yahaya

    2011-01-01

    This paper reports on the detection of several organic vapors using the unique characteristic of localized surface plasmon resonance (LSPR) gold nanoparticles. Gold nanoparticles on quartz substrate were prepared using seed mediated growth method. In a typical process, gold nanoparticles with average size ca. 36 nm were obtained to densely grown on the substrate. Detection of gas was based on the change in the LSPR of the gold nanoparticles film upon the exposure to the gas sample. It was found that gold nanoparticles were sensitive to the presence of volatile organic compound (VOC) gas from the change in the surface plasmon resonance (SPR) intensity. The mechanism for the detection of VOCs gas will be discussed. (author)

  10. Real-Time Pore Pressure Detection: Indicators and Improved Methods

    Directory of Open Access Journals (Sweden)

    Jincai Zhang

    2017-01-01

    Full Text Available High uncertainties may exist in the predrill pore pressure prediction in new prospects and deepwater subsalt wells; therefore, real-time pore pressure detection is highly needed to reduce drilling risks. The methods for pore pressure detection (the resistivity, sonic, and corrected d-exponent methods are improved using the depth-dependent normal compaction equations to adapt to the requirements of the real-time monitoring. A new method is proposed to calculate pore pressure from the connection gas or elevated background gas, which can be used for real-time pore pressure detection. The pore pressure detection using the logging-while-drilling, measurement-while-drilling, and mud logging data is also implemented and evaluated. Abnormal pore pressure indicators from the well logs, mud logs, and wellbore instability events are identified and analyzed to interpret abnormal pore pressures for guiding real-time drilling decisions. The principles for identifying abnormal pressure indicators are proposed to improve real-time pore pressure monitoring.

  11. Automated Peak Detection and Matching Algorithm for Gas Chromatography–Differential Mobility Spectrometry

    Science.gov (United States)

    Fong, Sim S.; Rearden, Preshious; Kanchagar, Chitra; Sassetti, Christopher; Trevejo, Jose; Brereton, Richard G.

    2013-01-01

    A gas chromatography–differential mobility spectrometer (GC-DMS) involves a portable and selective mass analyzer that may be applied to chemical detection in the field. Existing approaches examine whole profiles and do not attempt to resolve peaks. A new approach for peak detection in the 2D GC-DMS chromatograms is reported. This method is demonstrated on three case studies: a simulated case study; a case study of headspace gas analysis of Mycobacterium tuberculosis (MTb) cultures consisting of three matching GC-DMS and GC-MS chromatograms; a case study consisting of 41 GC-DMS chromatograms of headspace gas analysis of MTb culture and media. PMID:21204557

  12. Ion counting method and it's operational characteristics in gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    Fujii, Toshihiro

    1976-01-01

    Ion counting method with continuous channel electron multiplier which affords the direct detection of very small ion currents and it's operational characteristics were studied in gas chromatography-mass spectrometry. Then this method was applied to the single ion detection technique of GC-MS. A detection limit was measured, using various standard samples of low level concentration. (auth.)

  13. Detection of gas leakage

    Science.gov (United States)

    Thornberg, Steven M; Brown, Jason

    2015-02-17

    A method of detecting leaks and measuring volumes as well as a device, the Power-free Pump Module (PPM), provides a self-contained leak test and volume measurement apparatus that requires no external sources of electrical power during leak testing or volume measurement. The PPM is a portable, pneumatically-controlled instrument capable of generating a vacuum, calibrating volumes, and performing quantitative leak tests on a closed test system or device, all without the use of alternating current (AC) power. Capabilities include the ability is to provide a modest vacuum (less than 10 Torr) using a venturi pump, perform a pressure rise leak test, measure the gas's absolute pressure, and perform volume measurements. All operations are performed through a simple rotary control valve which controls pneumatically-operated manifold valves.

  14. Development of conjugate methods with gas chromatography for inorganic compounds analysis

    International Nuclear Information System (INIS)

    Baccan, N.

    1975-01-01

    The application of gas chromatography combined with mass spectrometry or with nuclear methods for the analysis of inorganic compounds is studied. The advantages of the use of a gas chromatograph coupled with a quadrupole mass spectrometer or with a high resolution radiation detector, are discussed. We also studied the formation and solvent extraction of metal chelates; an aliquot of the organic phase was directly injected into the gas chromatograph and the eluted compounds were detected by mass spectrometry or, when radioactive, by nuclear methods. (author)

  15. Sonographic detection of portal venous gas

    International Nuclear Information System (INIS)

    Lee, Wang Yul; Lee, S. K.; Cho, O. K.

    1989-01-01

    Portal venous gas suggests underlying bowel disease such as strangulating intestinal obstruction and its demonstration carries with it an important implications with respect to patient management. Radiography has been the gold standard for the detection of portal venous gas. We have experienced two cases of portal venous gas diagnosed by ultrasound. Sonographic findings were floating echoes in the main portal vein and highly echogenic linear or patchy echoes within the hepatic parenchyma. Simple abdominal films of those cases failed to demonstrate gas in the portal venous system

  16. A Gas Chromatographic System for the Detection of Ethylene Gas Using Ambient Air as a Carrier Gas.

    Science.gov (United States)

    Zaidi, Nayyer Abbas; Tahir, Muhammad Waseem; Vellekoop, Michael J; Lang, Walter

    2017-10-07

    Ethylene gas is a naturally occurring gas that has an influence on the shelf life of fruit during their transportation in cargo ships. An unintentional exposure of ethylene gas during transportation results in a loss of fruit. A gas chromatographic system is presented here for the detection of ethylene gas. The gas chromatographic system was assembled using a preconcentrator, a printed 3D printed gas chromatographic column, a humidity sensor, solenoid valves, and an electrochemical ethylene gas sensor. Ambient air was used as a carrier gas in the gas chromatographic system. The flow rate was fixed to 10 sccm. It was generated through a mini-pump connected in series with a mass flow controller. The metal oxide gas sensor is discussed with its limitation in ambient air. The results show the chromatogram obtained from metal oxide gas sensor has low stability, drifts, and has uncertain peaks, while the chromatogram from the electrochemical sensor is stable and precise. Furthermore, ethylene gas measurements at higher ppb concentration and at lower ppb concentration were demonstrated with the electrochemical ethylene gas sensor. The system separates ethylene gas and humidity. The chromatograms obtained from the system are stable, and the results are 1.2% repeatable in five similar measurements. The statistical calculation of the gas chromatographic system shows that a concentration of 2.3 ppb of ethylene gas can be detected through this system.

  17. Leak detection for city gas pipelines based on instantaneous energy distribution characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Zhigang, Chen [Deijing University of Civil Engineering and Architecture, Beijing, (China)

    2010-07-01

    Many natural gas pipelines are used in our cities. The development of efficient leakage detection systems is fundamental for safety issues avoidance. This paper investigated a new solution to the leak detection problem in city gas pipelines based on instantaneous energy distribution. In a theoretical approach, the Hilbert-Huang transform (HHT) was used to provide the instantaneous energy distribution feature of an unstable pressure signal. The signal noise was eliminated thanks to the instantaneous energy contribution. A leakage detection model with instantaneous energy distribution (IED) was then established. The correlation coefficients of instantaneous energy distribution were through correlation analysis. It was found that in different pipeline states, the instantaneous energy distribution characteristics are different. A strong correlation of IED signal characteristics was found of the two ends of a city gas pipeline in the same operation. The test results demonstrated the reliability and validity of the method.

  18. Thermally modulated nano-trampoline material as smart skin for gas molecular mass detection

    Science.gov (United States)

    Xia, Hua

    2012-06-01

    Conventional multi-component gas analysis is based either on laser spectroscopy, laser and photoacoustic absorption at specific wavelengths, or on gas chromatography by separating the components of a gas mixture primarily due to boiling point (or vapor pressure) differences. This paper will present a new gas molecular mass detection method based on thermally modulated nano-trampoline material as smart skin for gas molecular mass detection by fiber Bragg grating-based gas sensors. Such a nanomaterial and fiber Bragg grating integrated sensing device has been designed to be operated either at high-energy level (highly thermal strained status) or at low-energy level (low thermal strained status). Thermal energy absorption of gas molecular trigs the sensing device transition from high-thermal-energy status to low-thermal- energy status. Experiment has shown that thermal energy variation due to gas molecular thermal energy absorption is dependent upon the gas molecular mass, and can be detected by fiber Bragg resonant wavelength shift with a linear function from 17 kg/kmol to 32 kg/kmol and a sensitivity of 0.025 kg/kmol for a 5 micron-thick nano-trampoline structure and fiber Bragg grating integrated gas sensing device. The laboratory and field validation data have further demonstrated its fast response characteristics and reliability to be online gas analysis instrument for measuring effective gas molecular mass from single-component gas, binary-component gas mixture, and multi-gas mixture. The potential industrial applications include fouling and surge control for gas charge centrifugal compressor ethylene production, gas purity for hydrogen-cooled generator, gasification for syngas production, gasoline/diesel and natural gas fuel quality monitoring for consumer market.

  19. Gas leak detection in infrared video with background modeling

    Science.gov (United States)

    Zeng, Xiaoxia; Huang, Likun

    2018-03-01

    Background modeling plays an important role in the task of gas detection based on infrared video. VIBE algorithm is a widely used background modeling algorithm in recent years. However, the processing speed of the VIBE algorithm sometimes cannot meet the requirements of some real time detection applications. Therefore, based on the traditional VIBE algorithm, we propose a fast prospect model and optimize the results by combining the connected domain algorithm and the nine-spaces algorithm in the following processing steps. Experiments show the effectiveness of the proposed method.

  20. Detection and identification of radiation induced hydrocarbons in meets with the use of gas chromatography as one of methods for the detection of irradiated food

    International Nuclear Information System (INIS)

    Lehner, K.; Stachowicz, W.

    2000-01-01

    Results of the determination of the content of radiation induced hydrocarbons in meat samples (chicken, pork, beef) as well as proportion between the concentration of individual hydrocarbons in relation to the content of fatty acids in a given product are presented. The measurements have been done with the use of a Perkin Elmer model 8700 gas chromatograph equipped with a FID detector. The present study is a preliminary work on the implementation of a routine method for the detection of irradiation in foods that contain fats. (author)

  1. Alcohol Detection in Exhaled Air by NDIR Method

    Science.gov (United States)

    Fujitsuka, Norio; Yonemura, Masatoshi; Sakakibara, Kiyomi; Taguchi, Toshiyuki; Wakita, Toshihiro

    In recent years, the increase in traffic accidents associated with drunk driving has become a serious social issue. Therefore, there is a need for an in-vehicle system that can detect the fact that the driver is under the influence of alcohol. We thought a method for alcohol detection in the breath of the driver, based on a nondispersive infrared (NDIR) method, is suitable for this system. Since alcohol content in the driver's breath is significantly diluted at the sensor device, it is necessary that the sensor is highly sensitive to detect diluted alcohol. A quantum cascade laser was used to produce highly intense infrared light source. An infrared hollow fiber used in medical treatment was utilized as a gas absorption cell. Since the core of the fiber is hollow, gas is introduced for analyzer. The flexibility of the fiber allowed it to be looped so that 2 m fiber in length could be formed into a compact coil of 29 cm in diameter. It was clarified that the light intensity change of light output from the hollow fiber with ethanol density, and rarefied ethanol as small as 1 ppm in density was detected.

  2. Leakage detection in underground gas mains with radioaktive argon

    International Nuclear Information System (INIS)

    Schmitz, J.

    1975-01-01

    In the field of gas supply, radionuclide techniques are suitable for the routine monitoring of transport mains by means of highly active tracer clouds and a measuring scraper as well as for exact leakage detection in local gas distribution systems. Very good results are obtained in the case of mains lying lower than 1.5 m if the length and alignment of the pipe section allow a towing probe to be pulled through. This was investigated systematically on a model stretch under practical conditions. The attempts to detect leakages were made with the aid of the radioactive isotope 41 Ar. Under conditions close to practice concerning pipe bedding, branching, pre-pressure, and leakage diameter, a leak with leakage rates as small as approx. 1 l/min could be measured with the aid of a towing probe with a precision of +-0.5 m. This accuracy is another advantage of this method. Branching and fittings with a big dead volume do not interfere with the evaluation. The investment for this method can be compared to other physical/technical investigations on mains, e.g. weld seam tests. (orig./LN) [de

  3. Leak detection in gas pipeline by acoustic and signal processing - A review

    Science.gov (United States)

    Adnan, N. F.; Ghazali, M. F.; Amin, M. M.; Hamat, A. M. A.

    2015-12-01

    The pipeline system is the most important part in media transport in order to deliver fluid to another station. The weak maintenance and poor safety will contribute to financial losses in term of fluid waste and environmental impacts. There are many classifications of techniques to make it easier to show their specific method and application. This paper's discussion about gas leak detection in pipeline system using acoustic method will be presented in this paper. The wave propagation in the pipeline is a key parameter in acoustic method when the leak occurs and the pressure balance of the pipe will generated by the friction between wall in the pipe. The signal processing is used to decompose the raw signal and show in time- frequency. Findings based on the acoustic method can be used for comparative study in the future. Acoustic signal and HHT is the best method to detect leak in gas pipelines. More experiments and simulation need to be carried out to get the fast result of leaking and estimation of their location.

  4. Detection of outliers in gas centrifuge experimental data

    International Nuclear Information System (INIS)

    Andrade, Monica C.V.; Nascimento, Claudio A.O.

    2005-01-01

    Isotope separation in a gas centrifuge is a very complex process. Development and optimization of a gas centrifuge requires experimentation. These data contain experimental errors, and like other experimental data, there may be some gross errors, also known as outliers. The detection of outliers in gas centrifuge experimental data may be quite complicated because there is not enough repetition for precise statistical determination and the physical equations may be applied only on the control of the mass flows. Moreover, the concentrations are poorly predicted by phenomenological models. This paper presents the application of a three-layer feed-forward neural network to the detection of outliers in a very extensive experiment for the analysis of the separation performance of a gas centrifuge. (author)

  5. Materials For Gas Capture, Methods Of Making Materials For Gas Capture, And Methods Of Capturing Gas

    KAUST Repository

    Polshettiwar, Vivek

    2013-06-20

    In accordance with the purpose(s) of the present disclosure, as embodied and broadly described herein, embodiments of the present disclosure, in one aspect, relate to materials that can be used for gas (e.g., CO.sub.2) capture, methods of making materials, methods of capturing gas (e.g., CO.sub.2), and the like, and the like.

  6. Fabrication of a P3HT-ZnO Nanowires Gas Sensor Detecting Ammonia Gas

    Directory of Open Access Journals (Sweden)

    Chin-Guo Kuo

    2017-12-01

    Full Text Available In this study, an organic-inorganic semiconductor gas sensor was fabricated to detect ammonia gas. An inorganic semiconductor was a zinc oxide (ZnO nanowire array produced by atomic layer deposition (ALD while an organic material was a p-type semiconductor, poly(3-hexylthiophene (P3HT. P3HT was suitable for the gas sensing application due to its high hole mobility, good stability, and good electrical conductivity. In this work, P3HT was coated on the zinc oxide nanowires by the spin coating to form an organic-inorganic heterogeneous interface of the gas sensor for detecting ammonia gas. The thicknesses of the P3HT were around 462 nm, 397 nm, and 277 nm when the speeds of the spin coating were 4000 rpm, 5000 rpm, and 6000 rpm, respectively. The electrical properties and sensing characteristics of the gas sensing device at room temperature were evaluated by Hall effect measurement and the sensitivity of detecting ammonia gas. The results of Hall effect measurement for the P3HT-ZnO nanowires semiconductor with 462 nm P3HT film showed that the carrier concentration and the mobility were 2.7 × 1019 cm−3 and 24.7 cm2∙V−1∙s−1 respectively. The gas sensing device prepared by the P3HT-ZnO nanowires semiconductor had better sensitivity than the device composed of the ZnO film and P3HT film. Additionally, this gas sensing device could reach a maximum sensitivity around 11.58 per ppm.

  7. Gas detection in sands of high silt-clay content in the Cook Inlet area

    International Nuclear Information System (INIS)

    Bettis, F.

    1976-01-01

    When a sand contains a large amount of silt and clay it is often difficult to detect zones that contain gas using only the Archie Saturation Relationship. However, gas may be detected in these shaly formations using certain quick-look techniques. Log examples of these are presented in this paper. The first quick-look technique is an overlay of the neutron log on a density log. The neutron log is shifted relative to the density log to make the two porosity curves track in shaly water sands. Gas-bearing intervals become readily apparent from separations of the two curves where the density porosity is reading higher than the shifted neutron porosity. The second is an overlay of a neutron log on the sonic interval-transit-time log. The sonic log is shifted so as to match the neutron log in average tight sands in the section. This method has proved to be more optimistic than the density-neutron overlay above. It will find the gas-bearing zones, but may result in testing a zone or two which is nonproductive. The third method, used when no neutron log has been run, is a crossplot of the difference, sonic porosity minus density porosity, versus gamma ray API units. This is the most unreliable of the three methods because of the difficulty of determining the end points and the slope of the line on the plot which separates the gas zones from the non-gas zones

  8. Snowflake-Shaped ZnO Nanostructures-Based Gas Sensor for Sensitive Detection of Volatile Organic Compounds

    Directory of Open Access Journals (Sweden)

    Tianli Han

    2017-01-01

    Full Text Available Volatile organic compounds (VOCs have been considered severe risks to human health. Gas sensors for the sensitive detection of VOCs are highly required. However, the preparation of gas-sensing materials with a high gas diffusion performance remains a great challenge. Here, through a simple hydrothermal method accompanied with a subsequent thermal treatment, a special porous snowflake-shaped ZnO nanostructure was presented for sensitive detection of VOCs including diethyl ether, methylbenzene, and ethanol. The fabricated gas sensors exhibit a good sensing performance including high responses to VOCs and a short response/recovery time. The responses of the ZnO-based gas sensor to 100 ppm ethanol, methylbenzene, and diethyl ether are about 27, 21, and 11, respectively, while the response times to diethyl ether and methylbenzene are less than 10 seconds. The gas adsorption-desorption kinetics is also investigated, which shows that the gas-sensing behaviors to different target gases are remarkably different, making it possible for target recognition in practical applications.

  9. Wavelength modulation spectroscopy--digital detection of gas absorption harmonics based on Fourier analysis.

    Science.gov (United States)

    Mei, Liang; Svanberg, Sune

    2015-03-20

    This work presents a detailed study of the theoretical aspects of the Fourier analysis method, which has been utilized for gas absorption harmonic detection in wavelength modulation spectroscopy (WMS). The lock-in detection of the harmonic signal is accomplished by studying the phase term of the inverse Fourier transform of the Fourier spectrum that corresponds to the harmonic signal. The mathematics and the corresponding simulation results are given for each procedure when applying the Fourier analysis method. The present work provides a detailed view of the WMS technique when applying the Fourier analysis method.

  10. Novel gas-based detection techniques

    International Nuclear Information System (INIS)

    Graaf, Harry van der

    2009-01-01

    This year we celebrate the 100th birthday of gaseous detectors: Hans Geiger operated the first gas-filled counter in Manchester in 1908. The thin wires, essential for obtaining gas amplification, have been replaced by Micro Pattern Gas Detectors (MPGDs): Micromegas (1995) and GEM (1996). In the GridPix detector, each of the grid holes of a MPGD is equipped with its own electronic readout channel in the form of an active pixel in suitable pixel CMOS chips. By means of MEMS technology, the grid has been integrated with the chip, forming a monolithic readout device for gas volumes. By applying a protection layer made of hydrogenated amorphous silicon, the chips can be made spark proof. New protection layers have been made of silicon nitride. The use of gas as detection material for trackers is compared to Si, and the issue of chamber aging is addressed. New developments are set out: the development of Micro Channel Plates, integrated on pixel chips, the development of electron emission foil, and the realization of TimePix-2: a general-purpose pixel chip with time and amplitude measurement, per pixel, of charge signals.

  11. Fundamental study on leak detection of underground gas pipeline using passive acoustic method; Judogata onkyo keisoku ni yoru maisetsu gas dokan hason kasho no kenshutsu ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Jinguji, M; Imaizumi, H; Kunimatsu, S; Isei, T [National Institute for Resources and Environment, Tsukuba (Japan)

    1997-05-27

    With an objective to detect gas leaking from an underground gas pipeline, discussions have been given on a method which utilizes acoustic characteristics of leakage. On leaking sound generated from damaged portions, the form of damaging was hypothesized as pinholes, and spectra of leaking sounds from holes with different diameters were measured. The dominant frequency decreases as the hole diameter increases, while it is in a region of relatively high frequency of 1 kHz or higher. However, detection from the ground surface was impossible when cover soil has thickness from 0.5 to 1.5 m. In an experiment to measure leaking sound inside the pipe, pressure in the pipe was adjusted to 0.02 atm which is a standard pressure for a low-pressure pipe, and the sound was measured when the hole diameters were varied. In any of the results obtained by varying the hole diameter, spectra having the dominant frequency in the region of 1 kHz or higher were measured. In addition, it was found that sound pressure difference of as much as 50 dB at maximum is generated as compared with a case of no sound leakage. The above results verified that monitoring the high frequency of 1 kHz or higher is effective in detecting leakage from small damages. 2 refs., 4 figs.

  12. Microstructuring of piezoresistive cantilevers for gas detection and analysis

    International Nuclear Information System (INIS)

    Sarov, Y.; Sarova, V.; Bitterlich, Ch.; Richter, O.; Guliyev, E.; Zoellner, J.-P.; Rangelow, I. W.; Andok, R.; Bencurova, A.

    2011-01-01

    In this work we report on a design and fabrication of cantilevers for gas detection and analysis. The cantilevers have expanded area of interaction with the gas, while the signal transduction is realized by an integrated piezoresistive deflection sensor, placed at the narrowed cantilever base with highest stress along the cantilever. Moreover, the cantilevers have integrated bimorph micro-actuator detection in a static and dynamic mode. The cantilevers are feasible as pressure, temperature and flow sensors and under chemical functionalization - for gas recognition, tracing and composition analysis. (authors)

  13. Detection of greenhouse-gas-induced climatic change

    International Nuclear Information System (INIS)

    Wigley, T.M.L.; Jones, P.D.

    1992-01-01

    The aims of the US Department of Energy's Carbon Dioxide Research Program are to improve assessments of greenhouse-gas-induced climatic change and to define and reduce uncertainties through selected research. This project will address: The regional and seasonal details of the expected climatic changes; how rapidly will these changes occur; how and when will the climatic effects of CO 2 and other greenhouse gases be first detected; and the relationships between greenhouse-gas-induced climatic change and changes caused by other external and internal factors. The present project addresses all of these questions. Many of the diverse facets of greenhouse-gas-related climate research can be grouped under three interlinked subject areas: modeling, first detection and supporting data. This project will include the analysis of climate forcing factors, the development and refinement of transient response climate models, and the use of instrumental data in validating General Circulation Models (GCMs)

  14. Remote flammable gas detection/measuring device.

    CSIR Research Space (South Africa)

    Kononov, VA

    1999-11-01

    Full Text Available This research report presents the results of an evaluation of the existing open path remote flammable gas detection/monitoring technology and provides recommendations on possible limited implementation of this technology and future development...

  15. Gas detection by correlation spectroscopy employing a multimode diode laser.

    Science.gov (United States)

    Lou, Xiutao; Somesfalean, Gabriel; Zhang, Zhiguo

    2008-05-01

    A gas sensor based on the gas-correlation technique has been developed using a multimode diode laser (MDL) in a dual-beam detection scheme. Measurement of CO(2) mixed with CO as an interfering gas is successfully demonstrated using a 1570 nm tunable MDL. Despite overlapping absorption spectra and occasional mode hops, the interfering signals can be effectively excluded by a statistical procedure including correlation analysis and outlier identification. The gas concentration is retrieved from several pair-correlated signals by a linear-regression scheme, yielding a reliable and accurate measurement. This demonstrates the utility of the unsophisticated MDLs as novel light sources for gas detection applications.

  16. A fast, comprehensive screening method for doping agents in urine by gas chromatography-triple quadrupole mass spectrometry.

    Science.gov (United States)

    Van Eenoo, Peter; Van Gansbeke, Wim; De Brabanter, Nik; Deventer, Koen; Delbeke, Frans T

    2011-05-27

    The use of performance enhancing drugs in sports is prohibited. For the detection of misuse of such substances gas chromatography or liquid chromatography coupled to mass spectrometry are the most frequently used detection techniques. In this work the development and validation of a fast gas chromatography tandem mass spectrometric method for the detection of a wide range of doping agents is described. The method can determine 13 endogenous steroids (the steroid profile), 19-norandrosterone, salbutamol and 11-nor-Δ9-tetrahydrocannabinol.9carboxylic acid in the applicable ranges and to detect qualitatively over 140 substances in accordance with the minimum required performance levels of the World Anti-Doping Agency in 1ml of urine. The classes of substances included in the method are anabolic steroids, β2-agonists, stimulants, narcotics, hormone antagonists and modulators and beta-blockers. Moreover, using a short capillary column and hydrogen as a carrier gas the run time of the method is less than 8min. Copyright © 2010 Elsevier B.V. All rights reserved.

  17. Oxidative stress and pathogenic attack in plants, studied by laser based photoacoustic trace gas detection

    NARCIS (Netherlands)

    Santosa, Ignatius Edi

    2002-01-01

    Photoacoustic detection has proven to be a sensitive method, which is suitable for trace gas measurement. In this thesis, we improved the photoacoustic detection system to measure new biologically interesting gases, ethane (C2H6) and nitric oxide (NO). A new design of grating holder is incorporated

  18. Cross validation of gas chromatography-flame photometric detection and gas chromatography-mass spectrometry methods for measuring dialkylphosphate metabolites of organophosphate pesticides in human urine.

    Science.gov (United States)

    Prapamontol, Tippawan; Sutan, Kunrunya; Laoyang, Sompong; Hongsibsong, Surat; Lee, Grace; Yano, Yukiko; Hunter, Ronald Elton; Ryan, P Barry; Barr, Dana Boyd; Panuwet, Parinya

    2014-01-01

    We report two analytical methods for the measurement of dialkylphosphate (DAP) metabolites of organophosphate pesticides in human urine. These methods were independently developed/modified and implemented in two separate laboratories and cross validated. The aim was to develop simple, cost effective, and reliable methods that could use available resources and sample matrices in Thailand and the United States. While several methods already exist, we found that direct application of these methods required modification of sample preparation and chromatographic conditions to render accurate, reliable data. The problems encountered with existing methods were attributable to urinary matrix interferences, and differences in the pH of urine samples and reagents used during the extraction and derivatization processes. Thus, we provide information on key parameters that require attention during method modification and execution that affect the ruggedness of the methods. The methods presented here employ gas chromatography (GC) coupled with either flame photometric detection (FPD) or electron impact ionization-mass spectrometry (EI-MS) with isotopic dilution quantification. The limits of detection were reported from 0.10ng/mL urine to 2.5ng/mL urine (for GC-FPD), while the limits of quantification were reported from 0.25ng/mL urine to 2.5ng/mL urine (for GC-MS), for all six common DAP metabolites (i.e., dimethylphosphate, dimethylthiophosphate, dimethyldithiophosphate, diethylphosphate, diethylthiophosphate, and diethyldithiophosphate). Each method showed a relative recovery range of 94-119% (for GC-FPD) and 92-103% (for GC-MS), and relative standard deviations (RSD) of less than 20%. Cross-validation was performed on the same set of urine samples (n=46) collected from pregnant women residing in the agricultural areas of northern Thailand. The results from split sample analysis from both laboratories agreed well for each metabolite, suggesting that each method can produce

  19. Research on fiber-optic cantilever-enhanced photoacoustic spectroscopy for trace gas detection

    Science.gov (United States)

    Chen, Ke; Zhou, Xinlei; Gong, Zhenfeng; Yu, Shaochen; Qu, Chao; Guo, Min; Yu, Qingxu

    2018-01-01

    We demonstrate a new scheme of cantilever-enhanced photoacoustic spectroscopy, combining a sensitivity-improved fiber-optic cantilever acoustic sensor with a tunable high-power fiber laser, for trace gas detection. The Fabry-Perot interferometer based cantilever acoustic sensor has advantages such as high sensitivity, small size, easy to install and immune to electromagnetic. Tunable erbium-doped fiber ring laser with an erbium-doped fiber amplifier is used as the light source for acoustic excitation. In order to improve the sensitivity for photoacoustic signal detection, a first-order longitudinal resonant photoacoustic cell with the resonant frequency of 1624 Hz and a large size cantilever with the first resonant frequency of 1687 Hz are designed. The size of the cantilever is 2.1 mm×1 mm, and the thickness is 10 μm. With the wavelength modulation spectrum and second-harmonic detection methods, trace ammonia (NH3) has been measured. The gas detection limits (signal-to-noise ratio = 1) near the wavelength of 1522.5 nm is achieved to be 3 ppb.

  20. Determination of daminozide residues in apples using gas chromatography with nitrogen-phosphorus detection

    NARCIS (Netherlands)

    Brinkman, J.H.W.; Dijk, A.G. van; Wagenaar, R.; Quirijns, J.K.

    1996-01-01

    A method was developed for the determination of daminozide in apples using gas chromatography (GC) with nitrogen-phosphorus detection (NPD). Daminozide is hydrolysed to 1,1-dimethylhydrazine (UDMH) by alkaline digestion. The UDMH generated is distilled from the apple matrix, derivatized with

  1. Liquid metal-to-gas leak-detection instruments

    International Nuclear Information System (INIS)

    Matlin, E.; Witherspoon, J.E.; Johnson, J.L.

    1982-01-01

    It is desirable for liquid-metal-cooled reactors that small liquid metal-to-gas leaks be reliably detected. Testing has been performed on a number of detection systems to evaluate their sensitivity, response time, and performance characteristics. This testing has been scheduled in three phases. The first phase was aimed at screening out the least suitable detectors and optimizing the performance of the most promising. In the second phase, candidates were tested in a 1500 ft 3 walk-in type enclosure in which leaks were simulated on 24-in. and 3-in. piping. In the third phase of testing, selected type detectors were tested in the 1500-ft 3 enclosure with Clinch River Breeder Reactor Plant (CRBRP) pipe insulation configurations and detector tubing configuration with cell gas recirculation simulated. Endurance testing of detection equipment was also performed as part of this effort. Test results have been shown that aerosol-type detectors will reliably detect leaks as small as a few grams per hour when sampling pipe insulation annuli

  2. Methods of natural gas liquefaction and natural gas liquefaction plants utilizing multiple and varying gas streams

    Science.gov (United States)

    Wilding, Bruce M; Turner, Terry D

    2014-12-02

    A method of natural gas liquefaction may include cooling a gaseous NG process stream to form a liquid NG process stream. The method may further include directing the first tail gas stream out of a plant at a first pressure and directing a second tail gas stream out of the plant at a second pressure. An additional method of natural gas liquefaction may include separating CO.sub.2 from a liquid NG process stream and processing the CO.sub.2 to provide a CO.sub.2 product stream. Another method of natural gas liquefaction may include combining a marginal gaseous NG process stream with a secondary substantially pure NG stream to provide an improved gaseous NG process stream. Additionally, a NG liquefaction plant may include a first tail gas outlet, and at least a second tail gas outlet, the at least a second tail gas outlet separate from the first tail gas outlet.

  3. Photoacoustic Spectroscopy with Quantum Cascade Lasers for Trace Gas Detection

    Directory of Open Access Journals (Sweden)

    Gaetano Scamarcio

    2006-10-01

    Full Text Available Various applications, such as pollution monitoring, toxic-gas detection, noninvasive medical diagnostics and industrial process control, require sensitive and selectivedetection of gas traces with concentrations in the parts in 109 (ppb and sub-ppb range.The recent development of quantum-cascade lasers (QCLs has given a new aspect toinfrared laser-based trace gas sensors. In particular, single mode distributed feedback QCLsare attractive spectroscopic sources because of their excellent properties in terms of narrowlinewidth, average power and room temperature operation. In combination with these lasersources, photoacoustic spectroscopy offers the advantage of high sensitivity and selectivity,compact sensor platform, fast time-response and user friendly operation. This paper reportsrecent developments on quantum cascade laser-based photoacoustic spectroscopy for tracegas detection. In particular, different applications of a photoacoustic trace gas sensoremploying a longitudinal resonant cell with a detection limit on the order of hundred ppb ofozone and ammonia are discussed. We also report two QC laser-based photoacousticsensors for the detection of nitric oxide, for environmental pollution monitoring andmedical diagnostics, and hexamethyldisilazane, for applications in semiconductormanufacturing process.

  4. Gas chromatography with flame photometric detection of 31 organophosphorus pesticide residues in Alpinia oxyphylla dried fruits.

    Science.gov (United States)

    Zhao, Xiangsheng; Kong, Weijun; Wei, Jianhe; Yang, Meihua

    2014-11-01

    A simple, rapid and effective gas chromatography-flame photometric detection method was established for simultaneous multi-component determination of 31 organophosphorus pesticides (OPPs) residues in Alpinia oxyphylla, which is widely consumed as a traditional medicine and food in China. Sample preparation was completed in a single step without any clean-up procedure. All pesticides expressed good linear relationships between 0.004 and 1.0 μg/mL with correlation coefficients higher than 0.9973. The method gave satisfactory recoveries for most pesticides. The limits of detection varied from 1 to 10 ng/mL, and the limits of quantification (LOQs) were between 4 and 30 ng/mL. The proposed method was successfully applied to 55 commercial samples purchased from five different areas. Five pesticide residues were detected in four (7.27%) samples. The positive samples were confirmed by gas chromatography with tandem mass spectrometry (GC-MS/MS). Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Active mems microbeam device for gas detection

    KAUST Repository

    Bouchaala, Adam M.

    2017-10-05

    Sensors and active switches for applications in gas detection and other fields are described. The devices are based on the softening and hardening nonlinear response behaviors of microelectromechanical systems (MEMS) clamped-clamped microbeams. In that context, embodiments of gas-triggered MEMS microbeam sensors and switches are described. The microbeam devices can be coated with a Metal-Organic Framework to achieve high sensitivity. For gas sensing, an amplitude-based tracking algorithm can be used to quantify an amount of gas captured by the devices according to frequency shift. Noise analysis is also conducted according to the embodiments, which shows that the microbeam devices have high stability against thermal noise. The microbeam devices are also suitable for the generation of binary sensing information for alarming, for example.

  6. A new method for calculating gas saturation of low-resistivity shale gas reservoirs

    Directory of Open Access Journals (Sweden)

    Jinyan Zhang

    2017-09-01

    Full Text Available The Jiaoshiba shale gas field is located in the Fuling area of the Sichuan Basin, with the Upper Ordovician Wufeng–Lower Silurian Longmaxi Fm as the pay zone. At the bottom of the pay zone, a high-quality shale gas reservoir about 20 m thick is generally developed with high organic contents and gas abundance, but its resistivity is relatively low. Accordingly, the gas saturation calculated by formulas (e.g. Archie using electric logging data is often much lower than the experiment-derived value. In this paper, a new method was presented for calculating gas saturation more accurately based on non-electric logging data. Firstly, the causes for the low resistivity of shale gas reservoirs in this area were analyzed. Then, the limitation of traditional methods for calculating gas saturation based on electric logging data was diagnosed, and the feasibility of the neutron–density porosity overlay method was illustrated. According to the response characteristics of neutron, density and other porosity logging in shale gas reservoirs, a model for calculating gas saturation of shale gas was established by core experimental calibration based on the density logging value, the density porosity and the difference between density porosity and neutron porosity, by means of multiple methods (e.g. the dual-porosity overlay method by optimizing the best overlay coefficient. This new method avoids the effect of low resistivity, and thus can provide normal calculated gas saturation of high-quality shale gas reservoirs. It works well in practical application. This new method provides a technical support for the calculation of shale gas reserves in this area. Keywords: Shale gas, Gas saturation, Low resistivity, Non-electric logging, Volume density, Compensated neutron, Overlay method, Reserves calculation, Sichuan Basin, Jiaoshiba shale gas field

  7. Development of a detection sensor for lethal H2S gas.

    Science.gov (United States)

    Park, Young-Ho; Kim, Yong-Jae; Lee, Chang-Seop

    2012-07-01

    The gas which may be lethal to human body with short-term exposure in common industrial fields or workplaces in LAB may paralyze the olfactory sense and impose severe damages to central nervous system and lung. This study is concerned with the gas sensor which allows individuals to avoid the toxic gas that may be generated in the space with residues of organic wastes under 50 degrees C or above. This study investigates response and selectivity of the sensor to hydrogen sulfide gas with operating temperatures and catalysts. The thick-film semiconductor sensor for hydrogen sulfide gas detection was fabricated WO3/SnO2 prepared by sol-gel and precipitation methods. The nanosized SnO2 powder mixed with the various metal oxides (WO3, TiO2, and ZnO) and doped with transition metals (Au, Ru, Pd Ag and In). Particle sizes, specific surface areas and phases of sensor materials were investigated by SEM, BET and XRD analyses. The metal-WO3/SnO2 thick films were prepared by screen-printing method. The measured response to hydrogen sulfide gas is defined as the ratio (Ra/R,) of the resistance of WO3ISnO2 film in air to the resistance of WO3/SnO2 film in a hydrogen sulfide gas. It was shown that the highest response and selectivity of the sensor for hydrogen sulfide by doping with 1 wt% Ru and 10 wt% WO3 to SnO2 at the optimum operating temperature of 200 degrees C.

  8. Reduction of gas flow nonuniformity in gas turbine engines by means of gas-dynamic methods

    Science.gov (United States)

    Matveev, V.; Baturin, O.; Kolmakova, D.; Popov, G.

    2017-08-01

    Gas flow nonuniformity is one of the main sources of rotor blade vibrations in the gas turbine engines. Usually, the flow circumferential nonuniformity occurs near the annular frames, located in the flow channel of the engine. This leads to the increased dynamic stresses in blades and as a consequence to the blade damage. The goal of the research was to find an acceptable method of reducing the level of gas flow nonuniformity as the source of dynamic stresses in the rotor blades. Two different methods were investigated during this research. Thus, this study gives the ideas about methods of improving the flow structure in gas turbine engine. On the basis of existing conditions (under development or existing engine) it allows the selection of the most suitable method for reducing gas flow nonuniformity.

  9. Detection of outliers in a gas centrifuge experimental data

    Directory of Open Access Journals (Sweden)

    M. C. V. Andrade

    2005-09-01

    Full Text Available Isotope separation with a gas centrifuge is a very complex process. Development and optimization of a gas centrifuge requires experimentation. These data contain experimental errors, and like other experimental data, there may be some gross errors, also known as outliers. The detection of outliers in gas centrifuge experimental data is quite complicated because there is not enough repetition for precise statistical determination and the physical equations may be applied only to control of the mass flow. Moreover, the concentrations are poorly predicted by phenomenological models. This paper presents the application of a three-layer feed-forward neural network to the detection of outliers in analysis of performed on a very extensive experiment.

  10. FFTF fuel failure detection and characterization by cover gas monitoring. Final report

    International Nuclear Information System (INIS)

    Miller, W.C.; Holt, F.E.

    1977-01-01

    The Fast Flux Test Facility (FFTF) will include a Fuel Failure Monitoring (FFM) System designed to detect, characterize, and locate fuel and absorber pin failures (i.e., cladding breaches) using a combination of delayed neutron detection, cover gas radioisotope monitoring, and gas tagging. During the past several years the Hanford Engineering Development Laboratory has been involved in the development, design, procurement, and installation of this integrated system. The paper describes one portion of the FFM System, the Cover Gas Monitoring System (CGMS), which has the primary function of fuel failure detection and characterization in the FFTF. By monitoring the various radioisotopes in the cover gas, the CGMS will both detect fuel and absorber pin failures and characterize those failures as to magnitude and severity

  11. Active mems microbeam device for gas detection

    KAUST Repository

    Bouchaala, Adam M.; Jaber, Nizar; Younis, Mohammad I.

    2017-01-01

    Sensors and active switches for applications in gas detection and other fields are described. The devices are based on the softening and hardening nonlinear response behaviors of microelectromechanical systems (MEMS) clamped-clamped microbeams

  12. Soft X-ray-assisted detection method for airborne molecular contaminations (AMCs)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Changhyuk; Zuo, Zhili [University of Minnesota, Department of Mechanical Engineering (United States); Finger, Hartmut; Haep, Stefan; Asbach, Christof; Fissan, Heinz [Institute of Energy and Environmental Technology (IUTA e. V.) (Germany); Pui, David Y. H., E-mail: dyhpui@umn.edu [University of Minnesota, Department of Mechanical Engineering (United States)

    2015-03-15

    Airborne molecular contaminations (AMCs) represent a wide range of gaseous contaminants in cleanrooms. Due to the unintentional nanoparticle or haze formation as well as doping caused by AMCs, improved monitoring and controlling methods for AMCs are urgent in the semiconductor industry. However, measuring ultra-low concentrations of AMCs in cleanrooms is difficult, especially, behind a gas filter. In this study, a novel detection method for AMCs, which is on-line, economical, and applicable for diverse AMCs, was developed by employing gas-to-particle conversion with soft X-ray, and then measuring the generated nanoparticles. Feasibility study of this method was conducted through the evaluations of granular-activated carbons (GACs), which are widely used AMC filter media. Sulfur dioxide (SO{sub 2}) was used as an AMC for the feasibility study. Using this method, the ultra-low concentrations of SO{sub 2} behind GACs were determined in terms of concentrations of generated sulfuric acid (H{sub 2}SO{sub 4}) nanoparticles. By calculating SO{sub 2} concentrations from the nanoparticle concentrations using empirical correlation equations between them, remarkable sensitivity of this method to SO{sub 2} was shown, down to parts-per-trillions, which are too low to detect using commercial gas sensors. Also, the calculated SO{sub 2} concentrations showed good agreement with those measured simultaneously by a commercial SO{sub 2} monitor at parts-per-billions.

  13. Gas-Dynamic Methods to Reduce Gas Flow Nonuniformity from the Annular Frames of Gas Turbine Engines

    Science.gov (United States)

    Kolmakova, D.; Popov, G.

    2018-01-01

    Gas flow nonuniformity is one of the main sources of rotor blade vibrations in the gas turbine engines. Usually, the flow circumferential nonuniformity occurs near the annular frames, located in the flow channel of the engine. This leads to the increased dynamic stresses in blades and consequently to the blade damage. The goal of the research was to find an acceptable method of reducing the level of gas flow nonuniformity. Two different methods were investigated during this research. Thus, this study gives the ideas about methods of improving the flow structure in gas turbine engine. Based on existing conditions (under development or existing engine) it allows the selection of the most suitable method for reducing gas flow nonuniformity.

  14. An attempt to detect the greenhouse-gas signal in a transient GCM simulation

    International Nuclear Information System (INIS)

    Barnett, T.P.

    1990-01-01

    Results from the GISS model forced by transient greenhouse-gas (GHG) increases are used to demonstrate methods of detecting the theoretically predicted GHG signal. The signal predicted to occur in the surface temperature of the world's ocean since 1958 is not found in the observations but this is not surprising since the signal was small in the first place. The main result of the study is to demonstrate many of the key issues/difficulties that attend the detection problem

  15. A novel analytical method of 1-(3-trifluoromethylphenyl piperazine and 1-(3-chlorophenyl piperazine in fluids of drug addicts using liquid-liquid extraction-gas chromatographic/nitrogen-phosphorous detection

    Directory of Open Access Journals (Sweden)

    Jing Chang

    2017-01-01

    Full Text Available In accordance with the research specifications and guidelines in China, we developed a novel experimental method to detect new piperazine-type drugs, such as 1-(3-trifluoromethylphenyl piperazine and 1-(3-chlorophenyl piperazine. In this study, a new pretreatment method and gas chromatography (GC/nitrogen-phosphorus detector detection technique were used to characterize these two kinds of drugs in urine and blood samples. For the purpose of isolation of these trace drugs from the samples, liquid-liquid extraction/solid-phase extraction was modified and validated for this specific study. The pretreatment method presented in this paper has many advantages, such as high recovery rate, high extraction efficiency, high detection sensitivity, low limit of detection, and simple operation. The GC/NPD instrument is popular in most laboratories because it can meet the routine requirements of forensic science. All these aspects make this combination of sample pretreatment and GC/NPD technique the most suitable choice for drug detection in biological samples.

  16. Gas evolution as a rapid screening method for detection of irradiated foods

    International Nuclear Information System (INIS)

    Roberts, P.B.; Chambers, D.M.; Brailsford, G.W.

    1996-01-01

    A number of detection methods for irradiated foods are in advanced state of development. No single method is likely to be universally applicable but a battery of tests such as thermoluminescence, electron spin resonance and analysis of lipid radiolytic products may soon be available for most foods and technical uses of irradiation. Most of these proposed tests require relatively sophisticated equipment or technical skills and are often time consuming and costly. There would be value in relatively simple tests which could be used as a rapid screening system or confirmatory method. The literature on the use of radiolytic gases as a detection method is limited and this paper extends the above studies. In particular, it extends the work to frozen shellfish, for which irradiation has been used as a commercial decontaminant technique for many years, and considers the effect of storage temperature. Work on poultry is also reported as a cross-reference to earlier work and because irradiated poultry has recently been released into the US retail trade. (author)

  17. ACOUSTIC DETECTING AND LOCATING GAS PIPE LINE INFRINGEMENT

    Energy Technology Data Exchange (ETDEWEB)

    John L. Loth; Gary J. Morris; George M. Palmer; Richard Guiler; Patrick Browning

    2004-10-31

    The extensive network of high-pressure natural gas transmission pipelines covering the United States provides an important infrastructure for our energy independence. Early detection of pipeline leaks and infringements by construction equipment, resulting in corrosion fractures, presents an important aspect of our national security policy. The National Energy Technology Laboratory Strategic Center for Natural Gas (SCVG) is and has been funding research on various applicable techniques. The WVU research team has focused on monitoring pipeline background acoustic signals generated and transmitted by gas flowing through the gas inside the pipeline. In case of a pipeline infringement, any mechanical impact on the pipe wall, or escape of high-pressure gas, generates acoustic signals traveling both up and down stream through the gas. Sudden changes in flow noise are detectable with a Portable Acoustic Monitoring Package (PAMP), developed under this contract. It incorporates a pressure compensating microphone and a signal- recording device. Direct access to the gas inside the line is obtained by mounting such a PAMP, with a 1/2 inch NPT connection, to a pipeline pressure port found near most shut-off valves. An FFT of the recorded signal subtracted by that of the background noise recorded one-second earlier appears to sufficiently isolate the infringement signal to allow source interpretation. Using cell phones for data downloading might allow a network of such 1000-psi rated PAMP's to acoustically monitor a pipeline system and be trained by neural network software to positively identify and locate any pipeline infringement.

  18. ACOUSTIC DETECTING AND LOCATING GAS PIPE LINE INFRINGEMENT

    Energy Technology Data Exchange (ETDEWEB)

    John L. Loth; Gary J. Morris; George M. Palmer; Richard Guiler; Patrick Browning

    2004-12-01

    The extensive network of high-pressure natural gas transmission pipelines covering the United States provides an important infrastructure for our energy independence. Early detection of pipeline leaks and infringements by construction equipment, resulting in corrosion fractures, presents an important aspect of our national security policy. The National Energy Technology Laboratory Strategic Center for Natural Gas (SCVG) is and has been funding research on various applicable techniques. The WVU research team has focused on monitoring pipeline background acoustic signals generated and transmitted by gas flowing through the gas inside the pipeline. In case of a pipeline infringement, any mechanical impact on the pipe wall, or escape of high-pressure gas, generates acoustic signals traveling both up and down stream through the gas. Sudden changes in flow noise are detectable with a Portable Acoustic Monitoring Package (PAMP), developed under this contract. It incorporates a pressure compensating microphone and a signal- recording device. Direct access to the gas inside the line is obtained by mounting such a PAMP, with a 1/2 inch NPT connection, to a pipeline pressure port found near most shut-off valves. An FFT of the recorded signal subtracted by that of the background noise recorded one-second earlier appears to sufficiently isolate the infringement signal to allow source interpretation. Using cell phones for data downloading might allow a network of such 1000-psi rated PAMP's to acoustically monitor a pipeline system and be trained by neural network software to positively identify and locate any pipeline infringement.

  19. [A mobile sensor for remote detection of natural gas leakage].

    Science.gov (United States)

    Zhang, Shuai; Liu, Wen-qing; Zhang, Yu-jun; Kan, Rui-feng; Ruan, Jun; Wang, Li-ming; Yu, Dian-qiang; Dong, Jin-ting; Han, Xiao-lei; Cui, Yi-ben; Liu, Jian-guo

    2012-02-01

    The detection of natural gas pipeline leak becomes a significant issue for body security, environmental protection and security of state property. However, the leak detection is difficult, because of the pipeline's covering many areas, operating conditions and complicated environment. A mobile sensor for remote detection of natural gas leakage based on scanning wavelength differential absorption spectroscopy (SWDAS) is introduced. The improved soft threshold wavelet denoising was proposed by analyzing the characteristics of reflection spectrum. And the results showed that the signal to noise ratio (SNR) was increased three times. When light intensity is 530 nA, the minimum remote sensitivity will be 80 ppm x m. A widely used SWDAS can make quantitative remote sensing of natural gas leak and locate the leak source precisely in a faster, safer and more intelligent way.

  20. THIN FILM-BASED SENSOR FOR MOTOR VEHICLE EXHAUST GAS, NH3, AND CO DETECTION

    Directory of Open Access Journals (Sweden)

    S. Sujarwata

    2016-10-01

    Full Text Available A copper phthalocyanine (CuPc thin film based gas sensor with FET structure and channel length 100 μm has been prepared by VE method and lithography technique to detect NH3, motor cycle exhaust gases and CO. CuPc material layer was deposited on SiO2 by the vacuum evaporator (VE method at room temperature and pressure of 8 x10-4 Pa. The stages of manufacturing gas sensor were Si/SiO2 substrate blenching with ethanol in an ultrasonic cleaner, source, and drain electrodes deposition on the substrate by using a vacuum evaporator, thin film deposition between the source/drain and gate deposition. The sensor response times to NH3, motorcycle exhaust gases and CO were 75 s, 135 s, and 150, respectively. The recovery times were 90 s, 150 s and 225, respectively. It is concluded that the CuPc thin film-based gas sensor with FET structure is the best sensor to detect the NH3 gas.Sensor gas berbasis film tipis copper phthalocyanine (CuPc berstruktur FET dengan panjang channel 100 μm telah dibuatdengan metode VE dan teknik lithography untuk mendeteksi NH3 gas buang kendaraan bermotor dan CO. Lapisan bahan CuPc dideposisikan pada permukaan silikon dioksida (SiO2 dengan metode vacuum evaporator (VE pada temperatur ruang dengan tekanan 8 x10-4 Pa. Tahapan pembuatan sensor gas adalah pencucian substrat Si/SiO2 dengan etanol dalam ultrasonic cleaner, deposisi elektroda source dan drain di atas substrat dengan metode vacuum evaporator, deposisi film tipis diantara source/drain dan deposisi gate. Waktu tanggap sensor terhadap NH3, gas buang kendaraan bermotor dan CO berturut-turut adalah 75 s, 135 s,dan 150 s. Waktu pemulihan berturut-turut adalah 90 s, 150 s,dan 225 s. Disimpulkan bahwa sensor gas berstruktur FET berbasis film tipis CuPc merupakan sensor paling baik untuk mendeteksi adanya gas NH3.

  1. Methods of detecting tritium in gases and liquids

    Energy Technology Data Exchange (ETDEWEB)

    Petr, I

    1977-07-01

    Tritium mainly occurs in gases in two chemical forms, i.e., as water vapour (HTO) or elemental hydrogen (HT). Two methods for tritium gas measuring are described. The first consists in the use of an ionization chamber or a proportional counter with the sample sucked in through a filter to the detector working volume. The second consists in the separation of tritium (in the form of HTO) from the gas sample by sorption on silica gel or on molecular sieves and its detection using a liquid or a plastic scintillation detector. Tritium in the form of HT and gaseous organic tritium compounds are determined using the same measuring method after oxidation of the gaseous samples to HTO by burning. A description is given of detectors and measuring methods. Tritium in liquids mainly occurs in the form of tritiated water (HTO). The most commonly used method of tritium detection in liquids is the application of liquid scintillation detectors in which the sample is dissolved or suspended and measured with two photomultipliers in time-coincidence connection. The main advantage of liquid scintillators is the possibility to achieve the 4..pi.. measurement geometry. The methods of calibration and of checking the stability of a measuring system with liquid scintillators are described as are the applications of plastic scintillators in measuring tritium in liquids. Plastic scintillators are less costly in operation and show a more rapid response but their sensitivity is lower. The threshold values of activity are shown in dependence on the detector applied, the chemical form of tritium and the sampling method.

  2. Remote laser detection of natural gas leakages from pipelines

    International Nuclear Information System (INIS)

    Petukhov, V O; Gorobets, V A; Andreev, Yu M; Lanskii, G V

    2010-01-01

    A differential absorption lidar based on a tunable TEA CO 2 laser emitting at 42 lines of the 'hot' 01 1 1 - 11 1 0 band in the range from 10.9 to 11.4 μm is developed for detecting natural gas leakages from oil pipelines by measuring the ethane content in the atmosphere. The ethane detection sensitivity is 0.9 ppm km. The presence of methane does not distort the measurement results. The developed lidar can detect the natural gas leakage from kilometre heights at the flying velocities up to 200 km h -1 and a probe pulse repetition rate of 5 Hz. (laser applications and other topics in quantum electronics)

  3. Quantum-cascade laser photoacoustic detection of methane emitted from natural gas powered engines

    Science.gov (United States)

    Rocha, M. V.; Sthel, M. S.; Silva, M. G.; Paiva, L. B.; Pinheiro, F. W.; Miklòs, A.; Vargas, H.

    2012-03-01

    In this work we present a laser photoacoustic arrangement for the detection of the important greenhouse gas methane. A quantum-cascade laser and a differential photoacoustic cell were employed. A detection limit of 45 ppbv in nitrogen was achieved as well as a great selectivity. The same methodology was also tested in the detection of methane issued from natural gas powered vehicles (VNG) in Brazil, which demonstrates the excellent potential of this arrangement for greenhouse gas detection emitted from real sources.

  4. Electrospun ZnO Nanowires as Gas Sensors for Ethanol Detection

    Directory of Open Access Journals (Sweden)

    Huang Po-Jung

    2009-01-01

    Full Text Available Abstract ZnO nanowires were produced using an electrospinning method and used in gas sensors for the detection of ethanol at 220 °C. This electrospinning technique allows the direct placement of ZnO nanowires during their synthesis to bridge the sensor electrodes. An excellent sensitivity of nearly 90% was obtained at a low ethanol concentration of 10 ppm, and the rest obtained at higher ethanol concentrations, up to 600 ppm, all equal to or greater than 90%.

  5. Gas Detection for Experiments

    CERN Document Server

    Hay, D

    2001-01-01

    Flammable gases are often used in detectors for physics experiments. The storage, distribution and manipulation of such flammable gases present several safety hazards. As most flammable gases cannot be detected by human senses, specific well-placed gas detection systems must be installed. Following a request from the user group and in collaboration with CERN safety officers, risk analyses are performed. An external contractor, who needs to receive detailed user requirements from CERN, performs the installations. The contract is passed on a guaranteed results basis. Co-ordination between all the CERN groups and verification of the technical installation is done by ST/AA/AS. This paper describes and focuses on the structured methodology applied to implement such installations based on goal directed project management techniques (GDPM). This useful supervision tool suited to small to medium sized projects facilitates the task of co-ordinating numerous activities to achieve a completely functional system.

  6. Detection of Greenhouse-Gas-Induced Climatic Change

    Energy Technology Data Exchange (ETDEWEB)

    Jones, P.D.; Wigley, T.M.L.

    1998-05-26

    The objective of this report is to assemble and analyze instrumental climate data and to develop and apply climate models as a basis for (1) detecting greenhouse-gas-induced climatic change, and (2) validation of General Circulation Models.

  7. Is Optical Gas Imaging Effective for Detecting Fugitive Methane Emissions? - A Technological and Policy Perspective

    Science.gov (United States)

    Ravikumar, A. P.; Wang, J.; Brandt, A. R.

    2016-12-01

    Mitigating fugitive methane emissions from the oil and gas industry has become an important concern for both businesses and regulators. While recent studies have improved our understanding of emissions from all sectors of the natural gas supply chain, cost-effectively identifying leaks over expansive natural gas infrastructure remains a significant challenge. Recently, the Environmental Protection Agency (EPA) has recommended the use of optical gas imaging (OGI) technologies to be used in industry-wide leak detection and repair (LDAR) programs. However, there has been little to no systematic study of the effectiveness of infrared-camera-based OGI technology for leak detection applications. Here, we develop a physics-based model that simulates a passive infrared camera imaging a methane leak against varying background and ambient conditions. We verify the simulation tool through a series of large-volume controlled release field experiments wherein known quantities of methane were released and imaged from a range of distances. After simulator verification, we analyze the effects of environmental conditions like temperature, wind, and imaging background on the amount of methane detected from a statistically representative survey program. We also examine the effects of LDAR design parameters like imaging distance, leak size distribution, and gas composition. We show that imaging distance strongly affects leak detection - EPA's expectation of a 60% reduction in fugitive emissions based on a semi-annual LDAR survey will be realized only if leaks are imaged at a distance less than 10 m from the source under ideal environmental conditions. Local wind speed is also shown to be important. We show that minimum detection limits are 3 to 4 times higher for wet-gas compositions that contain a significant fraction of ethane and propane, resulting a significantly large leakage rate. We also explore the importance of `super-emitters' on the performance of an OGI-based leak

  8. Laser Calorimetry Spectroscopy for ppm-level Dissolved Gas Detection and Analysis.

    Science.gov (United States)

    K S, Nagapriya; Sinha, Shashank; R, Prashanth; Poonacha, Samhitha; Chaudhry, Gunaranjan; Bhattacharya, Anandaroop; Choudhury, Niloy; Mahalik, Saroj; Maity, Sandip

    2017-02-20

    In this paper we report a newly developed technique - laser calorimetry spectroscopy (LCS), which is a combination of laser absorption spectroscopy and calorimetry - for the detection of gases dissolved in liquids. The technique involves determination of concentration of a dissolved gas by irradiating the liquid with light of a wavelength where the gas absorbs, and measuring the temperature change caused by the absorbance. Conventionally, detection of dissolved gases with sufficient sensitivity and specificity was done by first extracting the gases from the liquid and then analyzing the gases using techniques such as gas chromatography. Using LCS, we have been able to detect ppm levels of dissolved gases without extracting them from the liquid. In this paper, we show the detection of dissolved acetylene in transformer oil in the mid infrared (MIR) wavelength (3021 nm) region.

  9. Development of failure detection system for gas-cooled reactor

    International Nuclear Information System (INIS)

    Feirreira, M.P.

    1990-01-01

    This work presents several kinds of Failure Detection Systems for Fuel Elements, stressing their functional principles and major applications. A comparative study indicates that the method of electrostatic precipitation of the fission gases Kr and Xe is the most efficient for fuel failure detection in gas-cooled reactors. A detailed study of the physical phenomena involved in electrostatic precipitation led to the derivation of an equation for the measured counting rate. The emission of fission products from the fuel and the ion recombination inside the chamber are evaluated. A computer program, developed to simulate the complete operation of the system, relates the counting rate to the concentration of Kr and Xe isotopes. The project of a mock-up is then presented. Finally, the program calculations are compared to experimental data, available from the literature, yielding a close agreement. (author)

  10. Modelling and interpretation of gas detection using remote laser pointers.

    Science.gov (United States)

    Hodgkinson, J; van Well, B; Padgett, M; Pride, R D

    2006-04-01

    We have developed a quantitative model of the performance of laser pointer style gas leak detectors, which are based on remote detection of backscattered radiation. The model incorporates instrumental noise limits, the reflectivity of the target background surface and a mathematical description of gas leak dispersion in constant wind speed and turbulence conditions. We have investigated optimum instrument performance and limits of detection in simulated leak detection situations. We predict that the optimum height for instruments is at eye level or above, giving an operating range of 10 m or more for most background surfaces, in wind speeds of up to 2.5 ms(-1). For ground based leak sources, we find laser pointer measurements are dominated by gas concentrations over a short distance close to the target surface, making their readings intuitive to end users in most cases. This finding is consistent with the results of field trials.

  11. Recent and innovative methods for detection of bacteremia and fungemia

    International Nuclear Information System (INIS)

    Reller, L.B.

    1983-01-01

    Advances continue to be made in methods for more reliable or more rapid means of detecting bacteremia and fungemia. The importance of blood sample volume and broth dilution has been established in controlled studies. New technology includes the use of resins that remove antimicrobials from blood samples, detection of radioactivity from organisms given radiolabeled substrate, use of dyes that stain microbial DNA and RNA, use of slides coated with growth media, and lysis-centrifugation for trapping microorganisms. Technology now being considered includes counterimmunoelectrophoresis, head-space gas chromatography, electrical impedance, microcalorimetry, and the use of lasers to detect pH changes and turbidity

  12. [Determination of 44 organophosphorus pesticides in food by SPE disk extraction-capillary gas chromatography with pulsed flame photometric detection].

    Science.gov (United States)

    Luo, Xiao-Fei; Yang, Yuan; Sun, Cheng-Jun

    2012-01-01

    To develop a method for the simultaneous determination of 44 organophosphorus pesticides in food by SPE disk extraction-capillary gas chromatography with pulsed flame photometric detection. Organophosphorus pesticides in food were extracted ultrasonically with water. Then the extract was cleaned-up with SPE disk and eluted with ethyl acetate. Finally the eluent was condensed to 1mL under N2 at 55 degrees C. Gas chromatography was applied for quantitative detection of the organophosphorus pesticides in the sample. The linear range of the method for all the pesticides were in the range of 0.01-0.5 mg/kg with correlation coefficients of 0.992-1.000. The detection limits of the method were in the range of 0.0005-0.01 mg/kg. The recoveries for most pesticides were 60%-120% with relative standard deviations of less than 15%. The method is simple, sensitive, environmentally friendly and suitable for the determination of organophosphorous pesticides in food.

  13. Time reversal technique for gas leakage detection.

    Science.gov (United States)

    Maksimov, A O; Polovinka, Yu A

    2015-04-01

    The acoustic remote sensing of subsea gas leakage traditionally uses sonars as active acoustic sensors and hydrophones picking up the sound generated by a leak as passive sensors. When gas leaks occur underwater, bubbles are produced and emit sound at frequencies intimately related to their sizes. The experimental implementation of an acoustic time-reversal mirror (TRM) is now well established in underwater acoustics. In the basic TRM experiment, a probe source emits a pulse that is received on an array of sensors, time reversed, and re-emitted. After time reversal, the resulting field focuses back at the probe position. In this study, a method for enhancing operation of the passive receiving system has been proposed by using it in the regime of TRM. Two factors, the local character of the acoustic emission signal caused by the leakage and a resonant nature of the bubble radiation at their birth, make particularly effective scattering with the conjugate wave (CW). Analytical calculations are performed for the scattering of CW wave on a single bubble when CW is formed by bubble birthing wail received on an array, time reversed, and re-emitted. The quality of leakage detection depends on the spatio-temporal distribution of ambient noise.

  14. Development of detection techniques for the Swedish noble gas sampler

    International Nuclear Information System (INIS)

    Ringbom, A.

    1998-11-01

    A short review on the radioactive properties of noble gas isotopes relevant for monitoring of nuclear activities is given, together with a brief discussion of the existing systems for detection of radioactive noble gases. A 4π detection system to be used in the automatic version of the Swedish noble gas sampling device is described. Monte Carlo calculations of the total gamma and beta efficiency for different detector designs have been performed, together with estimates of the resulting minimum detectable concentration (MDC). The estimated MDC values for detection of the 133g Xe 81 keV and the 135g Xe 250 keV gamma lines are around 0.3 mBq/m 3 in both cases. This is a factor of three lower than the detection limit required for a sampling station in the Comprehensive Nuclear-Test-Ban Treaty monitoring network. The possibility to modify the system to detect 85 Kr is also discussed

  15. Development of detection techniques for the Swedish noble gas sampler

    Energy Technology Data Exchange (ETDEWEB)

    Ringbom, A

    1998-11-01

    A short review on the radioactive properties of noble gas isotopes relevant for monitoring of nuclear activities is given, together with a brief discussion of the existing systems for detection of radioactive noble gases. A 4{pi} detection system to be used in the automatic version of the Swedish noble gas sampling device is described. Monte Carlo calculations of the total gamma and beta efficiency for different detector designs have been performed, together with estimates of the resulting minimum detectable concentration (MDC). The estimated MDC values for detection of the {sup 133g}Xe 81 keV and the {sup 135g}Xe 250 keV gamma lines are around 0.3 mBq/m{sup 3} in both cases. This is a factor of three lower than the detection limit required for a sampling station in the Comprehensive Nuclear-Test-Ban Treaty monitoring network. The possibility to modify the system to detect {sup 85}Kr is also discussed 27 refs, 13 figs, 3 tabs

  16. Fiber optic gas detection system for health monitoring of oil-filled transformer

    Science.gov (United States)

    Ho, H. L.; Ju, J.; Jin, W.

    2009-10-01

    This paper reports the development of a fiber-optic gas detection system capable of detecting three types of dissolved fault gases in oil-filled power transformers or equipment. The system is based on absorption spectroscopy and the target gases include acetylene (C2H2), methane (CH4) and ethylene (C2H4). Low-cost multi-pass sensor heads using fiber coupled micro-optic cells are employed for which the interaction length is up to 4m. Also, reference gas cells made of photonic bandgap (PBG) fiber are implemented. The minimum detectable gas concentrations for methane, acetylene and ethylene are 5ppm, 2ppm and 50ppm respectively.

  17. The Analysis of Pyrrolizidine Alkaloids in Jacobaea vulgaris; a Comparison of Extraction and Detection Methods

    NARCIS (Netherlands)

    Joosten, L.; Mulder, P.P.J.; Vrieling, K.; Veen, van der M.R.; Klinkhamer, P.G.L.

    2010-01-01

    Introduction – Pyrrolizidine alkaloids (PAs) serve an important function in plant defence. Objective – To compare different extraction methods and detection techniques, namely gas chromatography with nitrogen phosphorus detection (GC-NPD) and liquid chromatography tandem mass spectrometry (LC-MS/MS)

  18. Comparative Study of Gas Reconstruction Robust Methods for Multicomponent Gas Mixtures

    Directory of Open Access Journals (Sweden)

    V. A. Gorodnichev

    2015-01-01

    Full Text Available When using laser methods of gas analysis, one of the arising problems is instability in results of defining a quantitative composition of gases under control of multicomponent mixes in the conditions of real noise of measurements. It leads to demand for using the special algorithms to process results of laser measurements.For multicomponent gaseous mixes, when solving a problem of quantitative gas analysis based on the results of multispectral laser measurements, use of methods for solving incorrect mathematical tasks is efficient.If mix is stationary (i.e. there is a possibility for a series of measurements it is possible to use a much simpler method to determine concentration of gases, i.e. the least-squares method based on the minimization of residual function.However, the estimates obtained by the least-squares method are effective if distribution of measurement errors is according to the normal law. In practice, the law of errors distribution is often non-normal, and loss of estimate efficiency achieved by the least-squares method occurs even at a small share of bursts.With bursts available in the measuring signal, it is necessary to use the stationary estimation methods allowing the significantly reduced impact on the estimate of considerable bursts.To estimate an efficiency of the robust methods for defining a quantitative composition of the multicomponent stationary gas mixes from multispectral laser measurements a mathematical simulation was performed. A gas mixture was considered to be stationary, and n measurements (at each wavelength were taken ( n were specified from 2 to 6 to define a quantitative composition of gases in the mixture. Simulation was implemented for gas mixes with the number of components from 4 to 6.Results of mathematical simulation show that the robust estimate based on the residual function ( x  arctg x , allows us, in conditions of the bursts of a variable signal, to reduce significantly the error of

  19. Leakage detection of Marcellus Shale natural gas at an Upper Devonian gas monitoring well: a 3-d numerical modeling approach.

    Science.gov (United States)

    Zhang, Liwei; Anderson, Nicole; Dilmore, Robert; Soeder, Daniel J; Bromhal, Grant

    2014-09-16

    Potential natural gas leakage into shallow, overlying formations and aquifers from Marcellus Shale gas drilling operations is a public concern. However, before natural gas could reach underground sources of drinking water (USDW), it must pass through several geologic formations. Tracer and pressure monitoring in formations overlying the Marcellus could help detect natural gas leakage at hydraulic fracturing sites before it reaches USDW. In this study, a numerical simulation code (TOUGH 2) was used to investigate the potential for detecting leaking natural gas in such an overlying geologic formation. The modeled zone was based on a gas field in Greene County, Pennsylvania, undergoing production activities. The model assumed, hypothetically, that methane (CH4), the primary component of natural gas, with some tracer, was leaking around an existing well between the Marcellus Shale and the shallower and lower-pressure Bradford Formation. The leaky well was located 170 m away from a monitoring well, in the Bradford Formation. A simulation study was performed to determine how quickly the tracer monitoring could detect a leak of a known size. Using some typical parameters for the Bradford Formation, model results showed that a detectable tracer volume fraction of 2.0 × 10(-15) would be noted at the monitoring well in 9.8 years. The most rapid detection of tracer for the leak rates simulated was 81 days, but this scenario required that the leakage release point was at the same depth as the perforation zone of the monitoring well and the zones above and below the perforation zone had low permeability, which created a preferred tracer migration pathway along the perforation zone. Sensitivity analysis indicated that the time needed to detect CH4 leakage at the monitoring well was very sensitive to changes in the thickness of the high-permeability zone, CH4 leaking rate, and production rate of the monitoring well.

  20. Experimental study on engine gas-path component fault monitoring using exhaust gas electrostatic signal

    International Nuclear Information System (INIS)

    Sun, Jianzhong; Zuo, Hongfu; Liu, Pengpeng; Wen, Zhenhua

    2013-01-01

    This paper presents the recent development in engine gas-path components health monitoring using electrostatic sensors in combination with signal-processing techniques. Two ground-based engine electrostatic monitoring experiments are reported and the exhaust gas electrostatic monitoring signal-based fault-detection method is proposed. It is found that the water washing, oil leakage and combustor linear cracking result in an increase in the activity level of the electrostatic monitoring signal, which can be detected by the electrostatic monitoring system. For on-line health monitoring of the gas-path components, a baseline model-based fault-detection method is proposed and the multivariate state estimation technique is used to establish the baseline model for the electrostatic monitoring signal. The method is applied to a data set from a turbo-shaft engine electrostatic monitoring experiment. The results of the case study show that the system with the developed method is capable of detecting the gas-path component fault in an on-line fashion. (paper)

  1. Comparison of gas dehydration methods based on energy ...

    African Journals Online (AJOL)

    Comparison of gas dehydration methods based on energy consumption. ... PROMOTING ACCESS TO AFRICAN RESEARCH ... This study compares three conventional methods of natural gas (Associated Natural Gas) dehydration to carry out ...

  2. Two different hematocrit detection methods: Different methods, different results?

    Directory of Open Access Journals (Sweden)

    Schuepbach Reto A

    2010-03-01

    Full Text Available Abstract Background Less is known about the influence of hematocrit detection methodology on transfusion triggers. Therefore, the aim of the present study was to compare two different hematocrit-assessing methods. In a total of 50 critically ill patients hematocrit was analyzed using (1 blood gas analyzer (ABLflex 800 and (2 the central laboratory method (ADVIA® 2120 and compared. Findings Bland-Altman analysis for repeated measurements showed a good correlation with a bias of +1.39% and 2 SD of ± 3.12%. The 24%-hematocrit-group showed a correlation of r2 = 0.87. With a kappa of 0.56, 22.7% of the cases would have been transfused differently. In the-28%-hematocrit group with a similar correlation (r2 = 0.8 and a kappa of 0.58, 21% of the cases would have been transfused differently. Conclusions Despite a good agreement between the two methods used to determine hematocrit in clinical routine, the calculated difference of 1.4% might substantially influence transfusion triggers depending on the employed method.

  3. Research on Distributed Gas Detection Based on Hollow-core Photonic Crystal Fiber

    Directory of Open Access Journals (Sweden)

    Gui XIN

    2014-07-01

    Full Text Available We have demonstrated a distributed gas detection system by using hollow-core photonic crystal fiber (HC-PCF as a gas chamber. The HC-PCF gas chamber has several lateral micro- channels fabricated by the femtosecond laser. The HC-PCF is connected to the single mode fiber by thermal splicing, and gas can diffuse in hollow-core of PCF via micro-channels. Compared to the traditional gas chamber, the HC-PCF gas chamber has relatively simpler construction and quite stability. According to experiment results, the system response time of 15 s has been achieved for a 5 cm HC-PCF which has ten channels with 4mm channel distance. It would construct long sensing length fiber gas sensor that the side holes and the splicer have introduced very little loss. Thus make it possible to achieve highly sensitive sensing system without influencing the response time. By using self-reference demodulation algorithm and space division multiplexing technique, distributed gas detection system with fast response was achieved.

  4. Method and apparatus for manufacturing gas tags

    International Nuclear Information System (INIS)

    Gross, K.C.; Laug, M.T.

    1996-01-01

    For use in the manufacture of gas tags employed in a gas tagging failure detection system for a nuclear reactor, a plurality of commercial feed gases each having a respective noble gas isotopic composition are blended under computer control to provide various tag gas mixtures having selected isotopic ratios which are optimized for specified defined conditions such as cost. Using a new approach employing a discrete variable structure rather than the known continuous-variable optimization problem, the computer controlled gas tag manufacturing process employs an analytical formalism from condensed matter physics known as stochastic relaxation, which is a special case of simulated annealing, for input feed gas selection. For a tag blending process involving M tag isotopes with N distinct feed gas mixtures commercially available from an enriched gas supplier, the manufacturing process calculates the cost difference between multiple combinations and specifies gas mixtures which approach the optimum defined conditions. The manufacturing process is then used to control tag blending apparatus incorporating tag gas canisters connected by stainless-steel tubing with computer controlled valves, with the canisters automatically filled with metered quantities of the required feed gases. 4 figs

  5. [System design of open-path natural gas leakage detection based on Fresnel lens].

    Science.gov (United States)

    Xia, Hui; Liu, Wen-Qing; Zhang, Yu-Jun; Kan, Rui-Feng; Cui, Yi-Ben; Wang, Min; He, Ying; Cui, Xiao-Juan; Ruan, Jun; Geng, Hui

    2009-03-01

    Based on the technology of tunable diode laser absorption spectroscopy (TDLAS) in conjunction with second harmonic wave detection, a long open-path TDLAS system using a 1.65 microm InGaAsP distributed feedback laser was developed, which is used for detecting pipeline leakage. In this system, a high cost performance Fresnel lens is used as the receiving optical system, which receives the laser-beam reflected by a solid corner cube reflector, and focuses the receiving laser-beam to the InGaAs detector. At the same time, the influences of the concentration to the fluctuation of light intensity were taken into account in the process of measurement, and were eliminated by the method of normalized light intensity. As a result, the measurement error caused by the fluctuation of light intensity was made less than 1%. The experiment of natural gas leakage detection was simulated, and the detection sensitivity is 0.1 x 10(-6) (ratio by volume) with a total path of 320 m. According to the receiving light efficiency of the optical system and the detectable minimum light intensity of the detector, the detectable maximal optical path of the system was counted to be 2 000 m. The results of experiment show that it is a feasible design to use the Fresnel lens as the receiving optical system and can satisfy the demand of the leakage detection of natural gas.

  6. Gas-phase polynuclear aromatic hydrocarbons (PAH) in vehicle exhaust: A method for collection and analysis

    International Nuclear Information System (INIS)

    Seigl, W.O.; Chladek, E.

    1990-01-01

    Gas-phase polynuclear aromatic hydrocarbons (PAH) are emitted at low levels in vehicle exhaust compared to other hydrocarbon emissions. A method has been developed involving the trapping of gas phase emissions on Tenax, a macrorecticular porous polymer, followed by thermal desorption onto a capillary gas chromatography column. Gas chromatography/mass spectrometry (GC/MS) was used for the chemical analysis. A detection limit of 0.05 ng was achieved for several gas-phase PAH. This high sensitivity enables the speciation and quantitation of gas-phase PAH collected from a dilution tube during standard driving (test) cycles. The method was demonstrated for the analysis of 9 PAH in the exhaust from a 1987 vehicle (with and without catalyst) during the hot start transient phase of the EPA urban dynamometer driving schedule. The PAH measured include naphthalene, 2-methyl- and 1-methylnaphthalene, biphenyl, fluorene, phenanthrene, anthracene, fluoranthene and pyrene. The four most abundant PAH observed are naphthalene, 2-methyl and 1-methylnaphthalene, and biphenyl, in that order

  7. Detection and on-line prediction of leak magnitude in a gas pipeline using an acoustic method and neural network data processing

    Directory of Open Access Journals (Sweden)

    R. B. Santos

    2014-03-01

    Full Text Available Considering the importance of monitoring pipeline systems, this work presents the development of a technique to detect gas leakage in pipelines, based on an acoustic method, and on-line prediction of leak magnitude using artificial neural networks. On-line audible noises generated by leakage were obtained with a microphone installed in a 60 m long pipeline. The sound noises were decomposed into sounds of different frequencies: 1 kHz, 5 kHz and 9 kHz. The dynamics of these noises in time were used as input to the neural model in order to determine the occurrence and the leak magnitude. The results indicated the great potential of the technique and of the developed neural network models. For all on-line tests, the models showed 100% accuracy in leak detection, except for a small orifice (1 mm under 4 kgf/cm² of nominal pressure. Similarly, the neural network models could adequately predict the magnitude of the leakages.

  8. A Portable Array-Type Optical Fiber Sensing Instrument for Real-Time Gas Detection

    Directory of Open Access Journals (Sweden)

    San-Shan Hung

    2016-12-01

    Full Text Available A novel optical fiber array-type of sensing instrument with temperature compensation for real-time detection was developed to measure oxygen, carbon dioxide, and ammonia simultaneously. The proposed instrument is multi-sensing array integrated with real-time measurement module for portable applications. The sensing optical fibers were etched and polished before coating to increase sensitivities. The ammonia and temperature sensors were each composed of a dye-coated single-mode fiber with constructing a fiber Bragg grating and a long-period filter grating for detecting light intensity. Both carbon dioxide and oxygen sensing structures use multimode fibers where 1-hydroxy-3,6,8-pyrene trisulfonic acid trisodium salt is coated for carbon dioxide sensing and Tris(2,2′-bipyridyl dichlororuthenium(II hexahydrate and Tris(bipyridineruthenium(II chloride are coated for oxygen sensing. Gas-induced fluorescent light intensity variation was applied to detect gas concentration. The portable gas sensing array was set up by integrating with photo-electronic measurement modules and a human-machine interface to detect gases in real time. The measured data have been processed using piecewise-linear method. The sensitivity of the oxygen sensor were 1.54%/V and 9.62%/V for concentrations less than 1.5% and for concentrations between 1.5% and 6%, respectively. The sensitivity of the carbon dioxide sensor were 8.33%/V and 9.62%/V for concentrations less than 2% and for concentrations between 2% and 5%, respectively. For the ammonia sensor, the sensitivity was 27.78%/V, while ammonia concentration was less than 2%.

  9. A Portable Array-Type Optical Fiber Sensing Instrument for Real-Time Gas Detection.

    Science.gov (United States)

    Hung, San-Shan; Chang, Hsing-Cheng; Chang, I-Nan

    2016-12-08

    A novel optical fiber array-type of sensing instrument with temperature compensation for real-time detection was developed to measure oxygen, carbon dioxide, and ammonia simultaneously. The proposed instrument is multi-sensing array integrated with real-time measurement module for portable applications. The sensing optical fibers were etched and polished before coating to increase sensitivities. The ammonia and temperature sensors were each composed of a dye-coated single-mode fiber with constructing a fiber Bragg grating and a long-period filter grating for detecting light intensity. Both carbon dioxide and oxygen sensing structures use multimode fibers where 1-hydroxy-3,6,8-pyrene trisulfonic acid trisodium salt is coated for carbon dioxide sensing and Tris(2,2'-bipyridyl) dichlororuthenium(II) hexahydrate and Tris(bipyridine)ruthenium(II) chloride are coated for oxygen sensing. Gas-induced fluorescent light intensity variation was applied to detect gas concentration. The portable gas sensing array was set up by integrating with photo-electronic measurement modules and a human-machine interface to detect gases in real time. The measured data have been processed using piecewise-linear method. The sensitivity of the oxygen sensor were 1.54%/V and 9.62%/V for concentrations less than 1.5% and for concentrations between 1.5% and 6%, respectively. The sensitivity of the carbon dioxide sensor were 8.33%/V and 9.62%/V for concentrations less than 2% and for concentrations between 2% and 5%, respectively. For the ammonia sensor, the sensitivity was 27.78%/V, while ammonia concentration was less than 2%.

  10. Validation of an analytical method for simultaneous high-precision measurements of greenhouse gas emissions from wastewater treatment plants using a gas chromatography-barrier discharge detector system.

    Science.gov (United States)

    Pascale, Raffaella; Caivano, Marianna; Buchicchio, Alessandro; Mancini, Ignazio M; Bianco, Giuliana; Caniani, Donatella

    2017-01-13

    Wastewater treatment plants (WWTPs) emit CO 2 and N 2 O, which may lead to climate change and global warming. Over the last few years, awareness of greenhouse gas (GHG) emissions from WWTPs has increased. Moreover, the development of valid, reliable, and high-throughput analytical methods for simultaneous gas analysis is an essential requirement for environmental applications. In the present study, an analytical method based on a gas chromatograph (GC) equipped with a barrier ionization discharge (BID) detector was developed for the first time. This new method simultaneously analyses CO 2 and N 2 O and has a precision, measured in terms of relative standard of variation RSD%, equal to or less than 6.6% and 5.1%, respectively. The method's detection limits are 5.3ppm v for CO 2 and 62.0ppb v for N 2 O. The method's selectivity, linearity, accuracy, repeatability, intermediate precision, limit of detection and limit of quantification were good at trace concentration levels. After validation, the method was applied to a real case of N 2 O and CO 2 emissions from a WWTP, confirming its suitability as a standard procedure for simultaneous GHG analysis in environmental samples containing CO 2 levels less than 12,000mg/L. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. A new method for detecting pressure tube failures in Indian PHWRs

    International Nuclear Information System (INIS)

    Sharma, V.K.; Gupta, V.K.

    2000-01-01

    For the annulus gas system (AGS) of the standardised Indian pressurised heavy water reactor, an elaborate pressure tube (PT) crack monitoring and detection system is envisaged to ensure safety through leak-before-break. The parameters that are monitored relate to the detection of D 2 O moisture leaking in from the primary heat transport (PHT) system through a cracked PT. Since a slow build-up of moisture in the AGS may also occur for reasons other than PT failure, it is desirable that a diverse measurement technique should be available. This paper suggests such a technique, based on the observation that a small reference concentration of fission gases is normally present in the annulus gas. This concentration would change sharply upon PT failure, when the heavy water from the leaking PHT system releases the dissolved fission gas content into the annulus. This paper presents a theoretical study of the parameters that influence the build-up of fission product noble gases in the AGS and shows that leakage rates as low as 10 g h -1 from a PT crack can be detected in a few tens of minutes by this method. This is expected to substantially increase the available time between the leak detection and the PT failure, thus serving as an important tool in meeting the leak-before-break criterion of a critical component in PHWRs. (orig.)

  12. Detection of gas molecules on single Mn adatom adsorbed graphyne: a DFT-D study

    Science.gov (United States)

    Lu, Zhansheng; Lv, Peng; Ma, Dongwei; Yang, Xinwei; Li, Shuo; Yang, Zongxian

    2018-02-01

    As one of the prominent applications in intelligent systems, gas sensing technology has attracted great interest in both industry and academia. In the current study, the pristine graphyne (GY) without and with a single Mn atom is investigated to detect the gas molecules (CO, CH4, CO2, NH3, NO and O2). The pristine GY is promising to detect O2 molecules because of its chemical adsorption on GY with large electron transfer. The great stability of the Mn/GY is found, and the Mn atom prefers to anchor at the alkyne ring as a single atom. Upon single Mn atom anchoring, the sensitivity and selectivity of GY based gas sensors is significantly improved for various molecules, except CH4. The recovery time of the Mn/GY after detecting the gas molecules may help to appraise the detection efficiency for the Mn/GY. The current study will help to understand the mechanism of detecting the gas molecules, and extend the potentially fascinating applications of GY-based materials.

  13. A design of toxic gas detecting security robot car based on wireless path-patrol

    Directory of Open Access Journals (Sweden)

    Cheng Ho-Chih

    2017-01-01

    Full Text Available Because a toxic gas detecting/monitoring system in a chemical plant is not movable, a gas detecting/monitoring system will be passive and the detecting range will also be constrained. This invention is an active multi-functional wireless patrol car that can substitute for humans that inspect a plant's security. In addition, to widen the monitoring vision within the environment, two motors used to rotate a wireless IPCAM with two axes are presented. Also, to control the robot car's movement, two axis motors used to drive the wheel of the robot car are also installed. Additionally, a toxic gas detector is linked to the microcontroller of the patrol car. The detected concentration of the gas will be fed back to the server pc. To enhance the robot car's patrolling duration, a movable electrical power unit in conjunction with a wireless module is also used. Consequently, this paper introduces a wireless path-patrol and toxic gas detecting security robot car that can assure a plant's security and protect workers when toxic gases are emitted.

  14. Mobile Measurement of Methane and Ethane for the Detection and Attribution of Natural Gas Pipeline Leaks Using Off-Axis Integrated Output Spectroscopy

    Science.gov (United States)

    Leen, J. B.; Spillane, S.; Gardner, A.; Hansen, P. C.; Gupta, M.; Baer, D. S.

    2015-12-01

    Natural gas leaks pose a risk to public safety both because of potential explosions as well as from the greenhouse gas potential of fugitive methane. The rapid and cost effective detection of leaks in natural gas distribution is critical to providing a system that is safe for the public and the environment. Detection of methane from a mobile platform (vehicles, aircraft, etc.) is an accepted method of identifying leaks. A robust approach to differentiating pipeline gas (thermogenic) from other biogenic sources is the detection of ethane along with methane. Ethane is present in nearly all thermogenic gas but not in biogenic sources and its presence can be used to positively identify a gas sample. We present a mobile system for the simultaneous measurement of methane and ethane that is capable of detecting pipeline leaks and differentiating pipeline gas from other biogenic sources such as landfills, swamps, sewers, and enteric fermentation. The mobile system consists of a high precision GPS, sonic anemometer, and methane/ethane analyzer based on off-axis integrated cavity output spectroscopy (OA-ICOS). In order to minimize the system cost and facilitate the wide use of mobile leak detection, the analyzer operates in the near-infrared portion of the spectrum where lasers and optics are significantly less costly than in the mid-infrared. The analyzer is capable of detecting methane with a precision of detecting ethane with a precision of detection of leaks at speeds up to 50 mph. The sonic anemometer, GPS and analyzer inlet are mounted to a generic roof rack for attachment to available fleet vehicles. The system can detect leaks having a downwind concentration of as little as 10 ppb of methane above ambient, while leaks 500 ppb above ambient can be identified as thermogenic with greater than 99% certainty (for gas with 6% ethane). Finally, analysis of wind data provides an estimate of leak direction and distance. The system presented provides a robust, cost effective

  15. Detection of food irradiation - two analytical methods

    International Nuclear Information System (INIS)

    1994-01-01

    This publication summarizes the activities of Nordic countries in the field of detection of irradiated food. The National Food Agency of Denmark has coordinated the project. The two analytical methods investigated were: the gas-chromatographic determination of the hydrocarbon/lipid ratio in irradiated chicken meat, and a bioassay based on microelectrophoresis of DNA from single cells. Also a method for determination of o-tyrosine in the irradiated and non-irradiated chicken meat has been tested. The first method based on radiolytical changes in fatty acids, contained in chicken meat, has been tested and compared in the four Nordic countries. Four major hydrocarbons (C16:2, C16:3, C17:1 and C17:2) have been determined and reasonable agreement was observed between the dose level and hydrocarbons concentration. Results of a bioassay, where strand breaks of DNA are demonstrated by microelectrophoresis of single cells, prove a correlation between the dose levels and the pattern of DNA fragments migration. The hydrocarbon method can be applied to detect other irradiated, fat-containing foods, while the DNA method can be used for some animal and some vegetable foods as well.Both methods allow to determine the fact of food irradiation beyond any doubt, thus making them suitable for food control analysis. The detailed determination protocols are given. (EG)

  16. Gas centrifuge purge method

    Science.gov (United States)

    Theurich, Gordon R.

    1976-01-01

    1. In a method of separating isotopes in a high speed gas centrifuge wherein a vertically oriented cylindrical rotor bowl is adapted to rotate about its axis within an evacuated chamber, and wherein an annular molecular pump having an intake end and a discharge end encircles the uppermost portion of said rotor bowl, said molecular pump being attached along its periphery in a leak-tight manner to said evacuated chamber, and wherein end cap closure means are affixed to the upper end of said rotor bowl, and a process gas withdrawal and insertion system enters said bowl through said end cap closure means, said evacuated chamber, molecular pump and end cap defining an upper zone at the discharge end of said molecular pump, said evacuated chamber, molecular pump and rotor bowl defining a lower annular zone at the intake end of said molecular pump, a method for removing gases from said upper and lower zones during centrifuge operation with a minimum loss of process gas from said rotor bowl, comprising, in combination: continuously measuring the pressure in said upper zone, pumping gas from said lower zone from the time the pressure in said upper zone equals a first preselected value until the pressure in said upper zone is equal to a second preselected value, said first preselected value being greater than said second preselected value, and continuously pumping gas from said upper zone from the time the pressure in said upper zone equals a third preselected value until the pressure in said upper zone is equal to a fourth preselected value, said third preselected value being greater than said first, second and fourth preselected values.

  17. Method of processing radioactive gas

    International Nuclear Information System (INIS)

    Saito, Masayuki.

    1978-01-01

    Purpose: To reduce the quantity of radioactive gas discharged at the time of starting a nuclear power plant. Method: After the stoppage of a nuclear power plant air containing a radioactive gas is extracted from a main condenser by operating an air extractor. The air is sent into a gaseous waste disposal device, and then introduced into the activated carbon adsorptive tower of a rare gas holdup device where xenon and krypton are trapped. Thereafter, the air passes through pipelines and returned to the main condenser. In this manner, the radioactive gas contained in air within the main condenser is removed during the stoppage of the operation of the nuclear power plant. After the plant has been started, when it enters the normal operation, a flow control valve is closed and another valve is opened, and a purified gas exhausted from the rare gas holdup device is discharged into the atmosphere through an exhaust cylinder. (Aizawa, K.)

  18. Empirical Methods for Detecting Regional Trends and Other Spatial Expressions in Antrim Shale Gas Productivity, with Implications for Improving Resource Projections Using Local Nonparametric Estimation Techniques

    Science.gov (United States)

    Coburn, T.C.; Freeman, P.A.; Attanasi, E.D.

    2012-01-01

    The primary objectives of this research were to (1) investigate empirical methods for establishing regional trends in unconventional gas resources as exhibited by historical production data and (2) determine whether or not incorporating additional knowledge of a regional trend in a suite of previously established local nonparametric resource prediction algorithms influences assessment results. Three different trend detection methods were applied to publicly available production data (well EUR aggregated to 80-acre cells) from the Devonian Antrim Shale gas play in the Michigan Basin. This effort led to the identification of a southeast-northwest trend in cell EUR values across the play that, in a very general sense, conforms to the primary fracture and structural orientations of the province. However, including this trend in the resource prediction algorithms did not lead to improved results. Further analysis indicated the existence of clustering among cell EUR values that likely dampens the contribution of the regional trend. The reason for the clustering, a somewhat unexpected result, is not completely understood, although the geological literature provides some possible explanations. With appropriate data, a better understanding of this clustering phenomenon may lead to important information about the factors and their interactions that control Antrim Shale gas production, which may, in turn, help establish a more general protocol for better estimating resources in this and other shale gas plays. ?? 2011 International Association for Mathematical Geology (outside the USA).

  19. A pyrolysis/gas chromatographic method for the determination of hydrogen in solid samples

    Science.gov (United States)

    Carr, R. H.; Bustin, R.; Gibson, E. K.

    1987-01-01

    A method is described for the determination of hydrogen in solid samples. The sample is heated under vacuum after which the evolved gases are separated by gas chromatography with a helium ionization detector. The system is calibrated by injecting known amounts of hydrogen, as determined manometrically. The method, which is rapid and reliable, was checked for a variety of lunar soils; the limit of detection is about 10 ng of hydrogen.

  20. Materials For Gas Capture, Methods Of Making Materials For Gas Capture, And Methods Of Capturing Gas

    KAUST Repository

    Polshettiwar, Vivek; Patil, Umesh

    2013-01-01

    In accordance with the purpose(s) of the present disclosure, as embodied and broadly described herein, embodiments of the present disclosure, in one aspect, relate to materials that can be used for gas (e.g., CO.sub.2) capture, methods of making

  1. Methods for Detecting Microbial Methane Production and Consumption by Gas Chromatography.

    Science.gov (United States)

    Aldridge, Jared T; Catlett, Jennie L; Smith, Megan L; Buan, Nicole R

    2016-04-05

    Methane is an energy-dense fuel but is also a greenhouse gas 25 times more detrimental to the environment than CO 2 . Methane can be produced abiotically by serpentinization, chemically by Sabatier or Fisher-Tropsh chemistry, or biotically by microbes (Berndt et al. , 1996; Horita and Berndt, 1999; Dry, 2002; Wolfe, 1982; Thauer, 1998; Metcalf et al. , 2002). Methanogens are anaerobic archaea that grow by producing methane gas as a metabolic byproduct (Wolfe, 1982; Thauer, 1998). Our lab has developed and optimized three different gas chromatograph-utilizing assays to characterize methanogen metabolism (Catlett et al. , 2015). Here we describe the end point and kinetic assays that can be used to measure methane production by methanogens or methane consumption by methanotrophic microbes. The protocols can be used for measuring methane production or consumption by microbial pure cultures or by enrichment cultures.

  2. Hydrogen Gas Sensing Characteristics of Nanostructured NiO Thin Films Synthesized by SILAR Method

    Science.gov (United States)

    Karaduman, Irmak; Çorlu, Tugba; Yıldırım, M. Ali; Ateş, Aytunç; Acar, Selim

    2017-07-01

    Nanostructured NiO thin films have been synthesized by a facile, low-cost successive ionic layer adsorption and reaction (SILAR) method, and the effects of the film thickness on their hydrogen gas sensing properties investigated. The samples were characterized by scanning electron microscopy (SEM), x-ray diffraction (XRD) analysis, and energy-dispersive x-ray analysis. The XRD results revealed that the crystallinity improved with increasing thickness, exhibiting polycrystalline structure. SEM studies showed that all the films covered the glass substrate well. According to optical absorption measurements, the optical bandgap decreased with increasing film thickness. The gas sensing properties of the nanostructured NiO thin films were studied as a function of operating temperature and gas concentration. The samples showed good sensing performance of H2 gas with high response. The maximum response was 75% at operating temperature of 200°C for hydrogen gas concentration of 40 ppm. These results demonstrate that nanostructured NiO thin films synthesized by the SILAR method have potential for application in hydrogen detection.

  3. Analytical method validation of GC-FID for the simultaneous measurement of hydrocarbons (C2-C4) in their gas mixture

    OpenAIRE

    Oman Zuas; Harry budiman; Muhammad Rizky Mulyana

    2016-01-01

    An accurate gas chromatography coupled to a flame ionization detector (GC-FID) method was validated for the simultaneous analysis of light hydrocarbons (C2-C4) in their gas mixture. The validation parameters were evaluated based on the ISO/IEC 17025 definition including method selectivity, repeatability, accuracy, linearity, limit of detection (LOD), limit of quantitation (LOQ), and ruggedness. Under the optimum analytical conditions, the analysis of gas mixture revealed that each target comp...

  4. Nanomolecular gas sensor architectures based on functionalized carbon nanotubes for vapor detection

    Science.gov (United States)

    Hines, Deon; Zhang, Henan; Rümmeli, Mark H.; Adebimpe, David; Akins, Daniel L.

    2015-05-01

    There is enormous interest in detection of simple & complex odors by mean of electronic instrumentation. Specifically, our work focuses on creating derivatized-nanotube-based "electronic noses" for the detection and identification of gases, and other materials. We have grafted single-walled carbon nanotubes (SWNTs) with an array of electron-donating and electron withdrawing moieties and have characterized some of the physicochemical properties of the modified nanotubes. Gas sensing elements have been fabricated by spin coating the functionalized nanotubes onto interdigitated electrodes (IDE's), creating an array of sensors. Each element in the sensor array can contain a different functionalized matrix. This facilitates the construction of chemical sensor arrays with high selectivity and sensitivity; a methodology that mimics the mammalian olfactory system. Exposure of these coated IDEs to organic vapors and the successful classification of the data obtained under DC monitoring, indicate that the system can function as gas sensors of high repeatability and selectivity for a wide range of common analytes. Since the detection of explosive materials is also of concern in this research, our next phase focuses on explosives such as, TNT, RDX, and Triacetone Triperoxide (TATP). Sensor data from individual detection are assessed on their own individual merits, after which they are amalgamated and reclassified to present each vapor as unique data point on a 2-dimensional map and with minimum loss of information. This approach can assist the nation's need for a technology to defeat IEDs through the use of methods that detect unique chemical signatures associated with explosive molecules and byproducts.

  5. Development of the infrared instrument for gas detection

    Science.gov (United States)

    Chen, Ching-Wei; Chen, Chia-Ray

    2017-08-01

    MWIR (Mid-Wave Infrared) spectroscopy shows a large potential in the current IR devices market, due to its multiple applications, such as gas detection, chemical analysis, industrial monitoring, combustion and flame characterization. It opens this technique to the fields of application, such as industrial monitoring and control, agriculture and environmental monitoring. However, a major barrier, which is the lack of affordable specific key elements such a MWIR light sources and low cost uncooled detectors, have held it back from its widespread use. In this paper an uncooled MWIR detector combined with image enhancement technique is reported. This investigation shows good results in gas leakage detection test. It also verify the functions of self-developed MWIR lens and optics. A good agreement in theoretical design and experiment give us the lessons learned for the potential application in infrared satellite technology. A brief discussions will also be presented in this paper.

  6. A Novel Acoustic Liquid Level Determination Method for Coal Seam Gas Wells Based on Autocorrelation Analysis

    Directory of Open Access Journals (Sweden)

    Ximing Zhang

    2017-11-01

    Full Text Available In coal seam gas (CSG wells, water is periodically removed from the wellbore in order to keep the bottom-hole flowing pressure at low levels, facilitating the desorption of methane gas from the coal bed. In order to calculate gas flow rate and further optimize well performance, it is necessary to accurately monitor the liquid level in real-time. This paper presents a novel method based on autocorrelation function (ACF analysis for determining the liquid level in CSG wells under intense noise conditions. The method involves the calculation of the acoustic travel time in the annulus and processing the autocorrelation signal in order to extract the weak echo under high background noise. In contrast to previous works, the non-linear dependence of the acoustic velocity on temperature and pressure is taken into account. To locate the liquid level of a coal seam gas well the travel time is computed iteratively with the non-linear velocity model. Afterwards, the proposed method is validated using experimental laboratory investigations that have been developed for liquid level detection under two scenarios, representing the combination of low pressure, weak signal, and intense noise generated by gas flowing and leakage. By adopting an evaluation indicator called Crest Factor, the results have shown the superiority of the ACF-based method compared to Fourier filtering (FFT. In the two scenarios, the maximal measurement error from the proposed method was 0.34% and 0.50%, respectively. The latent periodic characteristic of the reflected signal can be extracted by the ACF-based method even when the noise is larger than 1.42 Pa, which is impossible for FFT-based de-noising. A case study focused on a specific CSG well is presented to illustrate the feasibility of the proposed approach, and also to demonstrate that signal processing with autocorrelation analysis can improve the sensitivity of the detection system.

  7. Fast and safe gas detection from underground coal fire by drone fly over

    International Nuclear Information System (INIS)

    Dunnington, Lucila; Nakagawa, Masami

    2017-01-01

    Underground coal fires start naturally or as a result of human activities. Besides burning away the important non-renewable energy resource and causing financial losses, burning coal seams emit carbon dioxide, carbon monoxide, sulfur oxide and methane, and is a leading cause of smog, acid rain, global warming, and air toxins. In the U.S. alone, the combined cost of coal-fire remediation projects that have been completed, budgeted, or projected by the U.S. Department of the Interior's Office of Surface Mining Remediation and Enforcement (OSM), exceeds $1 billion. It is estimated that these fires generate as much as 3% of the world's annual carbon dioxide emissions and consume as much as 5% of its minable coal. Considering the magnitude of environmental impact and economic loss caused by burning underground coal seams, we have developed a new, safe, reliable surface measurement of coal fire gases to assess the nature of underground coal fires. We use a drone mounted with gas sensors. Drone collected gas concentration data provides a safe alternative for evaluating the rank of a burning coal seam. In this study, a new method of determining coal rank by gas ratios is developed. Coal rank is valuable for defining parameters of a coal seam such as burn temperature, burn rate, and volume of burning seam. - Graphical abstract: Concluding Figure for Gas Ratios: Plotted points and ranges of adjusted literature data. Stars represent bituminous and subbituminous coal types; Ovals represent lignite. - Highlights: • Recognize underground coal fire as a potential source of energy. • Developed a creative, safe, reliable and fast gas detection method. • Developed a concept of gas ratio measurement method that can provide more accurate description of underground burning coal resource.

  8. Electron density measurement in gas discharge plasmas by optical and acoustic methods

    International Nuclear Information System (INIS)

    Biagioni, A.; Anania, M.P.; Bellaveglia, M.; Chiadroni, E.; Giovenale, D. Di; Pirro, G. Di; Ferrario, M.; Pompili, R.; Shpakov, V.; Vaccarezza, C.; Villa, F.; Cianchi, A.; Filippi, F.; Mostacci, A.; Zigler, A.

    2016-01-01

    Plasma density represents a very important parameter for both laser wakefield and plasma wakefield acceleration, which use a gas-filled capillary plasma source. Several techniques can be used to measure the plasma density within a capillary discharge, which are mainly based on optical diagnostic methods, as for example the well-known spectroscopic method using the Stark broadening effect. In this work, we introduce a preliminary study on an alternative way to detect the plasma density, based on the shock waves produced by gas discharge in a capillary. Firstly, the measurements of the acoustic spectral content relative to the laser-induced plasmas by a solid target allowed us to understand the main properties of the acoustic waves produced during this kind of plasma generation; afterwards, we have extended such acoustic technique to the capillary plasma source in order to calibrate it by comparison with the stark broadening method.

  9. Determination of ifosfamide, 2-and 3-dechloroethyifosfamide using gas chromatography with nitrogen-phosphorus or mass spectrometry detection

    NARCIS (Netherlands)

    Kerbusch, T; Jeuken, MJ; Derraz, J; van Putten, JWG; Huitema, ADR; Beijnen, JH

    2000-01-01

    A comparison was made between methods for determining ifosfamide (IF), 2- (2DCE) and 3-dechloroethylifosfamide (3DCE) using gas chromatography with nitrogen-phosphorus detection (GC-NPD) versus positive ion electron-impact ion-trap mass spectrometry (GC-MS'). Sample pretreatment involved

  10. Risk assessment of failure modes of gas diffuser liner of V94.2 siemens gas turbine by FMEA method

    Science.gov (United States)

    Mirzaei Rafsanjani, H.; Rezaei Nasab, A.

    2012-05-01

    Failure of welding connection of gas diffuser liner and exhaust casing is one of the failure modes of V94.2 gas turbines which are happened in some power plants. This defect is one of the uncertainties of customers when they want to accept the final commissioning of this product. According to this, the risk priority of this failure evaluated by failure modes and effect analysis (FMEA) method to find out whether this failure is catastrophic for turbine performance and is harmful for humans. By using history of 110 gas turbines of this model which are used in some power plants, the severity number, occurrence number and detection number of failure determined and consequently the Risk Priority Number (RPN) of failure determined. Finally, critically matrix of potential failures is created and illustrated that failure modes are located in safe zone.

  11. Express method and radon gas measurement detector

    International Nuclear Information System (INIS)

    Khajdarov, R.A.; Khajdarov, R.R.

    2004-01-01

    The purpose of this work was to improve the activated charcoal adsorption method. The detector consisted of an electronic unit (200 mm x 180 mm x 80 mm) and a scintillation cell (a tube 200 mm long, 60 mm diam.). The electronic unit contained a power supply, amplifier, discriminator, timer, counter and indicator. The scintillation cell contained a zinc sulfide scintillator, photomultiplier, preamplifier, high voltage power supply and a 200 ml chamber above the scintillator. This chamber was intended to situate activated carbon fibrous absorber and air compressor. In this method, air is drawn through a filter to remove radon decay products and then through the activated carbon cloth by using a compressor. Sampling takes between 5 and 15 minutes. After the sampling, the cloth is heated for 5-10 sec up to 200-250 deg C by electric current passing through the fiber. Radon gas evaporates from the cloth and the device detects scintillation pulses. Owing to a high radon preconcentration factor (by adsorption of radon on the activated carbon cloth from 50-150 L of air of and evaporation into the small volume of the chamber), the detection limit of the method is 2-4 Bq/m 3 . Since the distance between the filter, cloth and scintillator is over 80 mm, the detector only measures radiation from radon without interference from the radon decay products, remaining in the filter and cloth

  12. System and method for treatment of a flue gas

    Science.gov (United States)

    Spiry, Irina Pavlovna; Wood, Benjamin Rue; Singh, Surinder Prabhjot; Perry, Robert James; McDermott, John Brian

    2017-09-19

    A method for treatment of a flue gas involves feeding the flue gas and a lean solvent to an absorber. The method further involves reacting the flue gas with the lean solvent within the absorber to generate a clean flue gas and a rich solvent. The method also involves feeding the clean flue gas from the absorber and water from a source, to a wash tower to separate a stripped portion of the lean solvent from the clean flue gas to generate a washed clean flue gas and a mixture of the water and the stripped portion of the lean solvent. The method further involves treating at least a portion of the mixture of the water and the stripped portion of the lean solvent via a separation system to separate the water from the stripped portion of the lean solvent.

  13. Plasma wave detection in laser spectroscopy and gas chromatography

    International Nuclear Information System (INIS)

    Franzke, J.; Irmer, A. von; Veza, D.; Niemax, K.

    1995-01-01

    Frequency changes of plasma oscillations in low-pressure discharges are used for sensitive detection of atomic or molecular trace gases. Analyte selectivity can be either obtained by resonant laser excitation or by gas chromatography

  14. The study on the lidar's detection limit for Iodine Gas

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong-lyul; Baik, Seung-Hoon; Park, Seung-Kyu; Park, Nak-Gyu; Ahn, Yong-Jin [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    A powerful and reliable tool for range-resolved remote sensing of gas concentrations that has proven its capabilities in a variety of studies is the differential absorption lidar (DIAL). Differential absorption lidar (DIAL) is frequently used for atmospheric gas monitoring to detect impurities such as nitrogen dioxide, sulfur dioxide, iodine, and ozone. DIAL can measure air pollutant concentrations with a high spatial resolution by adopting two laser systems with different degrees of absorption between the two different wavelengths. The absorption of the reference wavelength is very weak, while the absorption of the other wavelength is very strong. In this paper, we measured the limit of detection capability of our designed DIAL system. The DIAL measurements were performed using a target iodine cell in the laboratory. We confirmed that the concentration of iodine gas ratio increased after the laser passed through the iodine cell. The system of DIAL(Differential Absorption Lidar) was effective to detect the iodine gas. We obtained the signals from the iodine target cell and the lidar signal from the iodine target cell was proportional to frequency locking ratios.

  15. Risetime discrimination applied to pressurized Xe gas proportional counter for hard x-ray detection

    International Nuclear Information System (INIS)

    Fujii, Masami; Doi, Kosei

    1978-01-01

    A high pressure Xe proportional counter has been developed for hard X-ray observation. This counter has better energy-resolving power than a NaI scintillation counter, and the realization of large area is relatively easy. This counter is constructed with a cylindrical aluminum tube, and this tube can be used at 40 atmospheric pressure. The detection efficiency curves were obtained in relation to gas pressure. It is necessary to reduce impurities in the Xe gas to increase the energy-resolving power of the counter. The increase of gas pressure made the resolving power worse. The characteristics of the counter were stable for at least a few months. The wave form discrimination was applied to reduce the background signals such as pulses caused by charged particles and gamma-ray. This method has been used for normal pressure counter, and in the present study, it was applied for the high pressure counter. It was found that the discrimination method was able to be applied to this case. (Kato, T.)

  16. Upconversion enhanced degenerate four-wave mixing in the mid-infrared for sensitive detection of acetylene in gas flows

    DEFF Research Database (Denmark)

    Høgstedt, Lasse; Dam, Jeppe Seidelin; Sahlberg, Anna-Lena

    2014-01-01

    We present a new background free method for in situ gas detection that combines degenerate four-wave mixing with an infra-red light detector based on parametric frequency upconversion of infra-red light. The system is demonstrated at mid infrared wavelengths for low concentration measurements...... of acetylene diluted in a N2 gas flow at ambient conditions. It is demonstrated that the system is able to cover more than 100 nm in scanning range and detect concentrations as low as 3 ppm based on the R9e line. A major issue in small signal measurements is scattered light and it is showed how a spatial...

  17. Powers of detection : technology companies vie to capture leak survey business for natural gas pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Byfield, M.

    2005-09-01

    ITT Industries Inc., Physical Sciences Inc., and LaSen Inc. are 3 American companies leading the way to find more efficient methods for identifying leaks from natural gas pipelines. Edmonton-based Synodon Inc. has recently joined the leaders with its newly developed and more sensitive equipment that it hopes to have on the market by the summer of 2006. Leak detection technology was first developed in 1993 in response to concerns about the reliability of aging pipeline infrastructure. In addition to safety concerns, there are concerns over global warming. Methane is a potential greenhouse gas and the United states Environmental Protection Agency estimates that 300 billion cubic feet escape into the atmosphere every year from pipeline leaks. The 2002 Pipeline Safety Improvement Bill in the United States stipulates that leak inspections must be conducted up to 4 times per year in densely populated areas. Violators face fines as high as $1 million. In response to the pipeline safety bill, Synodon raised private equity financing to commercialize an airborne leak detection technology stemming from Canada's space program. In the United States, leak detection technologies that appear likely to take 5 to 20 years for commercialization have been been financed by the Department of Energy and the Office of Pipeline Safety. This paper summarized 5 leak detection prototypes, including ITT's Airborne Natural Gas Emission LiDAR (ANGEL) system which targets high-pressure, long-distance pipelines in North America, LaSen's Airborne LiDAR Pipeline Inspection System (ALPIS) based on DIAL Technology, and a hand-held remote methane leak detector developed jointly by Physical Sciences Inc. of Massachusetts and Houston-based Heath Consultants Inc. Synodon claims that hand-held detectors are too slow and that LiDAR systems still aren't reliable for detection of leaks much below 500 scf/h. Synodon's realSens technology may be more difficult to develop, but it detects

  18. Visual detection of gas shows from coal core and cuttings using liquid leak detector

    Energy Technology Data Exchange (ETDEWEB)

    Barker, C.E. [United States Geological Survey, Denver, CO (United States)

    2006-09-15

    Coal core descriptions are difficult to obtain, as they must be obtained immediately after the core is retrieved and before the core is closed in a canister. This paper described a method of marking gas shows on a core surface by coating the core with a water-based liquid leak detector and photographing the subsequent foam developed on the core surface while the core is still in the core tray. Coals from a borehole at the Yukon Flats Basin in Alaska and the Maverick Basin in Texas were used to illustrate the method. Drilling mud and debris were removed from the coal samples before the leak detector solution was applied onto the core surfaces. A white froth or dripping foam developed rapidly at gas shows on the sample surfaces. A hand-held lens and a binocular microscope were used to magnify the foaming action. It was noted that foaming was not continuous across the core surface, but was restricted to localized points along the surface. It was suggested that the localized point foaming may have resulted from the coring process. However, the same tendency toward point gas show across the sample surface was found in some hard, well-indurated samples that still had undisturbed bedding and other sedimentary structures. It was concluded that gas shows marked as separate foam centres may indicate a real condition of local permeability paths. Results suggested that the new gas show detection method could be used in core selection studies to reduce the costs of exploration programs. 6 refs., 4 figs.

  19. Combined raman and IR fiber-based sensor for gas detection

    Science.gov (United States)

    Carter, Jerry C; Chan, James W; Trebes, James E; Angel, Stanley M; Mizaikoff, Boris

    2014-06-24

    A double-pass fiber-optic based spectroscopic gas sensor delivers Raman excitation light and infrared light to a hollow structure, such as a hollow fiber waveguide, that contains a gas sample of interest. A retro-reflector is placed at the end of this hollow structure to send the light back through the waveguide where the light is detected at the same end as the light source. This double pass retro reflector design increases the interaction path length of the light and the gas sample, and also reduces the form factor of the hollow structure.

  20. Detecting buried radium contamination using soil-gas and surface-flux radon meaurements

    International Nuclear Information System (INIS)

    Karp, K.E.

    1988-06-01

    The Technical Measurements Center (TMC) has investigated the effectiveness of using radon soil-gas under surface-flux measurments to locate radium contamination that is buried sufficiently deep to be undetectable by surface gamma methods. At the first test site studied, an indication of a buried source was revealed by mapping anomalous surface-flux and soil-gas concentrations in the near surface overburden. The mapped radon anomalies were found to correspond in rough outline to the shape of the areal extent of the deposit as determined by borehole gamma-ray logs. The 5.9pCi/g radium deposit, buried 2 feet below the surface, went undetected by conventional surface gamma measurements. Similar results were obtained at the second test site where radon and conventional surface gamma measurements were taken in an area having radium concentrations ranging from 13.3 to 341.0 pCi/g at a depth of 4 feet below the surface. The radon methods were found to have a detection limit for buried radium lower than that of the surface gamma methods, as evidenced by the discovery of the 13.3 pCi/g deposit which went undetected by the surface gamma methods. 15 refs., 33 figs., 8 tabs

  1. Detection of gases and gas mixtures by correlation spectroscopy

    OpenAIRE

    Dakin, J.P.; Gunning, M.J.; Chambers, P.

    2002-01-01

    The reliable detection and monitoring of gases and gas mixtures is known to play a crucial role in many real-world environmental and industrial applications. It is of considerable importance to utilise techniques that are not susceptible to poisoning, are specific to a target gas in a mixture, are unaffected by contaminants, and can be adapted for in-process monitoring. Ever-more stringent requirements in this field dictate a need for ongoing research in this area. As many common gases exhibi...

  2. Gas sensors for ammonia detection based on polyaniline-coated multi-wall carbon nanotubes

    International Nuclear Information System (INIS)

    He Lifang; Jia Yong; Meng Fanli; Li Minqiang; Liu Jinhuai

    2009-01-01

    Polyaniline-coated multi-wall carbon nanotubes (PANI-coated MWNTs) were prepared by in situ polymerization method. Field emission scanning electron microscopy, transmission electron microscopy, Raman spectroscopy, and thermogravimetric analysis were used to characterize the as-prepared PANI-coated MWNTs. Obtained results indicated that PANI was uniformly coated on MWNTs, and the thickness of the coatings can be controlled by changing the weight ratios of aniline monomer and MWNTs in the polymerization process. Sensors were fabricated by spin-coating onto pre-patterned electrodes, and ammonia gas sensing properties of the as-prepared PANI-coated MWNTs were studied. The results showed a good response and reproducibility towards ammonia at room temperature. In addition, PANI-coated MWNTs exhibited a linear response to ammonia in the range of 0.2-15 ppm. The effects of the thickness of PANI coatings on the gas sensing properties were also investigated in detail. The results suggest a potential application of PANI-coated MWNTs in gas sensor for detecting ammonia.

  3. Gas detection by means of surface plasmon resonance enhanced ellipsometry

    Energy Technology Data Exchange (ETDEWEB)

    Nooke, Alida

    2012-11-01

    This thesis investigated gas sensing by means of surface plasmon resonance enhanced ellipsometry. Surface plasmons were excited in a 40 - 50 nm gold layer by a He-Ne-laser using the Kretschmann configuration, which was arranged on a self-made copper measuring cell. A fixed angle of incidence and the ellipsometric parameter {Delta} as the measured value were used to monitor changes in the gas phase. Different types of gases were investigated: flammable (hydrocarbons and hydrogen), oxidising (oxygen and ozone), toxic (carbon monoxide) and inert (helium and nitrogen). The gas types can be distinguished by their refractive indices, whereas the sensor responds instantly relative to the reference gas with an increase or a decrease in {Delta}. Diluting the analyte gas with a reference gas (nitrogen or air) allowed the detection limits to be determined, these lay in the low % range. The sensor stability was also enhanced as well as the sensitivity by modifying the gold layers with a 3-10 nm additional layer. These additional layers consisted of the inorganic materials TiO{sub 2}, ZrO{sub 2}, MgF{sub 2} and Fe: SnO{sub 2} which were deposited by different coating processes. Surface investigations were made of every utilised layer: scanning electron microscope and atomic force microscope measurements for surface topology and spectroscopic ellipsometry mapping to determine the optical constants and the layer thicknesses. All applied materials protected the gold layer from contaminations and thus prolonged the life span of the sensor. Furthermore, the detection limits were reduced significantly, to the low ppm range. The material Fe: SnO{sub 2} demonstrates a special behaviour in reaction with the toxic gas carbon monoxide: Due to the iron doping, the response to carbon monoxide is extraordinary and concentrations below 1 ppm were detected. In order to approach a future application in industry, the sensor system was adapted to a stainless steel tube. With this measuring

  4. Rapid method for Detection of Irradiation Mango Fruits

    International Nuclear Information System (INIS)

    El Salhy, F.T.

    2011-01-01

    To detect mango fruits which have been exposed to low doses of gamma rays (0.5-3.0 kGy), three recommended methods by European Committee for Standardization (EN 1784:1996, EN 1785:1996 and EN 1787:2000) were used to study the possibility for identification of irradiated mango fruits (Ewais variety). Fresh mangoes were irradiated to different doses (0.5, 0.75, 1.0 and 3.0 kGy). The first method for determining the volatile hydrocarbons (VHC) was carried out by using florisil column then identified by gas chromatography and mass spectrometry (GC-MS). The major VHCs were C14:1, C15:0 and C17:1 at different doses which increased linearly with increasing doses either at low or high doses. The second one for determining the 2-alkyl cyclobutanone (2-DCB) was carried out using florisil chromatography method activated with 20% for separation and identified by GC-MS. 2-DCB bio marker specific for irradiated food proved its presence at the applied doses from 0.75-3.0 kGy but not at 0.5 kGy. All the mentioned compounds could not detected in non-irradiated samples, which mean that these radiolytic products (VHC and 2-DCB) can be used as a detection markers for irradiated mangoes even at low doses. The third one (EN 1787:2000) was conducted by electron spin resonance (ESR) on dried petioles of mangoes. The results proved that ESR was more sensitive for all applied doses.It could be concluded that using the three methods can be succeeded for detection of irradiated mangoes but the rapid one even at low doses with high accuracy was ESR.

  5. Investigation of Natural Gas Fugitive Leak Detection Using an Unmanned Aerial Vehicle

    Science.gov (United States)

    Yang, S.; Talbot, R. W.; Frish, M. B.; Golston, L.; Aubut, N. F.; Zondlo, M. A.

    2017-12-01

    The U.S is now the world's largest natural gas producer, of which methane (CH4) is the main component. About 2% of the CH4 is lost through fugitive leaks. This research is under the DOE Methane Observation Networks with Innovative Technology to Obtain Reductions (MONITOR) program of ARPA-E. Our sentry measurement system is composed of four state-of-the-art technologies centered around the RMLDTM (Remote Methane Leak Detector). An open path RMLDTM measures column-integrated CH4 concentration that incorporates fluctuations in the vertical CH4 distribution. Based on Backscatter Tunable Diode Laser Absorption Spectroscopy and Small Unmanned Aerial Vehicles, the sentry system can autonomously, consistently and cost-effectively monitor and quantify CH4 leakage from sites associated with natural gas production. This system provides an advanced capability in detecting leaks at hard-to-access sites (e.g., wellheads) compared to traditional manual methods. Automated leak detecting and reporting algorithms combined with wireless data link implement real-time leak information reporting. Early data were gathered to set up and test the prototype system, and to optimize the leak localization and calculation strategies. The flight pattern is based on a raster scan which can generate interpolated CH4 concentration maps. The localization and quantification algorithms can be derived from the plume images combined with wind vectors. Currently, the accuracy of localization algorithm can reach 2 m and the calculation algorithm has a factor of 2 accuracy. This study places particular emphasis on flux quantification. The data collected at Colorado and Houston test fields were processed, and the correlation between flux and other parameters analyzed. Higher wind speeds and lower wind variation are preferred to optimize flux estimation. Eventually, this system will supply an enhanced detection capability to significantly reduce fugitive CH4 emissions in the natural gas industry.

  6. The Precise Mechanisms of a High-Speed Ultrasound Gas Sensor and Detecting Human-Specific Lung Gas Exchange

    Directory of Open Access Journals (Sweden)

    Hideki Toda

    2012-12-01

    Full Text Available In this paper, we propose and develop a new real-time human respiration process analysis method using a high-time-sampling gas concentration sensor based on ultrasound. A unique point about our proposed gas concentration sensor is its 1 kHz gas concentration sampling speed. This figure could not have been attained by previously proposed gas concentration measurement methods such as InfraRed, semiconductor gas sensors, or GC-MS, because the gas analysis speeds were a maximum of a few hundred milliseconds. First, we describe the proposed new ultrasound sound speed measurement method and the signal processing, and present the measurement circuit diagram. Next, we analyse the human respiration gas variation patterns of five healthy subjects using a newly developed gas-mask-type respiration sensor. This reveals that the rapid gas exchange from H2O to CO2 contains air specific to the human being. In addition, we also measured medical symptoms in subjects suffering from asthma, hyperventilation and bronchial asthma. The millisecond level high-speed analysis of the human respiration process will be useful for the next generation of healthcare, rehabilitation and sports science technology.

  7. Instrument for detecting gas bubbles in sodium filled pipework

    Energy Technology Data Exchange (ETDEWEB)

    Stapleton, D

    1973-08-01

    An instrument employing an electromagnetic sensor is described. Gas bubbles down to 0.5 mm diameter can be detected in sodium filled pipework of 1 in. nominal bore at temperatures up to 400 deg C. Installation of the sensing head involves no break in the integrity of the pipework. Facilities to enable bubble size discrimination, bubble counting and timing pulse generation are provided in the signal processing unit. Initial operating experience has been gained on a sodium loop used for gas entrainment studies. (auth)

  8. Particle detection systems and methods

    Science.gov (United States)

    Morris, Christopher L.; Makela, Mark F.

    2010-05-11

    Techniques, apparatus and systems for detecting particles such as muons and neutrons. In one implementation, a particle detection system employs a plurality of drift cells, which can be for example sealed gas-filled drift tubes, arranged on sides of a volume to be scanned to track incoming and outgoing charged particles, such as cosmic ray-produced muons. The drift cells can include a neutron sensitive medium to enable concurrent counting of neutrons. The system can selectively detect devices or materials, such as iron, lead, gold, uranium, plutonium, and/or tungsten, occupying the volume from multiple scattering of the charged particles passing through the volume and can concurrently detect any unshielded neutron sources occupying the volume from neutrons emitted therefrom. If necessary, the drift cells can be used to also detect gamma rays. The system can be employed to inspect occupied vehicles at border crossings for nuclear threat objects.

  9. Gas Analysis and Control Methods for Thermal Batteries

    Science.gov (United States)

    2013-09-01

    when using highly efficient microporous thermal insulation packages. An easily implemented method of H2 gas removal from vendor thermal batteries is... microporous thermal insulation packages (1, 4, 5) or reduce volume requirements significantly. More rigorous gas control methods combined with...measured from the DCM pressures and known internal volumes of the 3 GHS that were measured using the ideal gas law with a 10-cc internal volume SS

  10. Energy resolution in X-ray detecting micro-strip gas counters

    CERN Document Server

    Bateman, J E; Derbyshire, G E; Duxbury, D M; Mir, J A; Spill, E J; Stephenson, R

    2002-01-01

    Systematic measurements of the energy resolution available from a Micro-Strip Gas Counter (MSGC) are presented. The effect of factors such as bias potential, gas filling and strip geometry on the energy resolution are examined in detail and related to a simple model. The geometry of the MSGC is adapted to permit 'wall-less' detection of X-rays and this results in useful improvements in the pulse height spectra.

  11. CO and CO2 dual-gas detection based on mid-infrared wideband absorption spectroscopy

    Science.gov (United States)

    Dong, Ming; Zhong, Guo-qiang; Miao, Shu-zhuo; Zheng, Chuan-tao; Wang, Yi-ding

    2018-03-01

    A dual-gas sensor system is developed for CO and CO2 detection using a single broadband light source, pyroelectric detectors and time-division multiplexing (TDM) technique. A stepper motor based rotating system and a single-reflection spherical optical mirror are designed and adopted for realizing and enhancing dual-gas detection. Detailed measurements under static detection mode (without rotation) and dynamic mode (with rotation) are performed to study the performance of the sensor system for the two gas samples. The detection period is 7.9 s in one round of detection by scanning the two detectors. Based on an Allan deviation analysis, the 1σ detection limits under static operation are 3.0 parts per million (ppm) in volume and 2.6 ppm for CO and CO2, respectively, and those under dynamic operation are 9.4 ppm and 10.8 ppm for CO and CO2, respectively. The reported sensor has potential applications in various fields requiring CO and CO2 detection such as in the coal mine.

  12. Identification of defluidization region in a gas-solid fluidized bed using a method based on pressure fluctuation measurements

    Directory of Open Access Journals (Sweden)

    M. R. Parise

    2009-09-01

    Full Text Available Industrial applications that involve fluidized bed operations must prevent the undesirable phenomenon of partial or complete bed defluidization. Defluidization can be avoided by increasing the gas velocity and/or, in some cases, changing the solid feed conditions in the system, provided that the changes in the hydrodynamics of the flow are detected early enough. The use of a technique that can perform an early detection of the defluidization condition in industrial applications is important, in order to avoid the loss of efficiency or even an undesirable shutting down of the process. The objective of this work is to show the application of a method for early detection of the condition where the bed is tending to the defluidization, in a gas-solid fluidized bed flow. The method is based on pressure fluctuation measurements. Experimental tests are carried out using two solid particles: microcrystalline cellulose and sand. Results show that the proposed method is efficient in detecting the fluidization condition in a conventional bubbling bed regime. The potential of application of the technique is also shown for the control of the defluidization phenomenon in industry.

  13. Detection of lysergic acid diethylamide (LSD) in urine by gas chromatography-ion trap tandem mass spectrometry.

    Science.gov (United States)

    Sklerov, J H; Kalasinsky, K S; Ehorn, C A

    1999-10-01

    A confirmatory method for the detection and quantitation of lysergic acid diethylamide (LSD) is presented. The method employs gas chromatography-tandem mass spectrometry (GC-MS-MS) using an internal ionization ion trap detector for sensitive MS-MS-in-time measurements of LSD extracted from urine. Following a single-step solid-phase extraction of 5 mL of urine, underivatized LSD can be measured with limits of quantitation and detection of 80 and 20 pg/mL, respectively. Temperature-programmed on-column injections of urine extracts were linear over the concentration range 20-2000 pg/mL (r2 = 0.999). Intraday and interday coefficients of variation were LSD-positive samples in this laboratory. Comparisons with alternate GC-MS methods and extraction procedures are discussed.

  14. Graphene oxide for gas detection under standard humidity conditions

    International Nuclear Information System (INIS)

    Donarelli, Maurizio; Prezioso, Stefano; Perrozzi, Francesco; Ottaviano, Luca; Giancaterini, Luca; Cantalini, Carlo; Treossi, Emanuele; Palermo, Vincenzo; Santucci, Sandro

    2015-01-01

    Graphene oxide (GO) synthesis is the easiest way to functionalize graphene, preserving the high graphene surface to volume ratio. Therefore, GO is a promising candidate for gas sensing applications. In this paper, an easy-to-fabricate and high sensitivity GO-based gas sensor is proposed. The device is fabricated by drop-casting a solution of GO flakes dispersed in water on a prepatterned Si 3 N 4 substrate with 30 μm spaced Pt electrodes. The sensing material has been studied using scanning electron microscopy and x-ray photoelectron spectroscopy. The large lateral dimensions of the flakes (tens of microns) allow single GO flake to bridge adjacent electrodes. The high quality of the synthesized flakes results in the gas sensor high sensitivity to and low detection limit (20 ppb) of NO 2 . The gas sensor response to NO 2 has been studied in various relative humidity environments and it is demonstrated not to be affected by the presence of water vapor. Finally, the gas sensor responses to acetone, toluene, ethanol, and ammonia are reported. (paper)

  15. Selective gas exhaustion method

    International Nuclear Information System (INIS)

    Hirano, Yoichi

    1998-01-01

    The present invention provides a method capable of evacuating gases at an exhaustion rate which varies depending on the kind of gases. For example, in a thermonuclear experimental device, a hydrogen gas exhaustion rate is determined to 0 and an exhaustion rate for other impure gases is made greater. Namely, a baffle plate is cooled to a temperature to a level at which the vapor pressure of gases to evacuate a baffle plate is required in a pump incorporating a baffle plate, for example, a cryopump or a sorption pump. In this case, the level of the vapor pressure required for evacuating the exhaustion gas ingredients is 1 x 10 -8 Torr or less, preferably, 1 x 10 -9 Torr. In a thermonuclear experimental device, a gas having a lower boiling point next to hydrogen is neon, but neon is scarcely present in natural world. Nitrogen has a lower boiling point next thereto, and if the temperature is lowered to such a level that the vapor pressure for evacuating gases such as nitrogen, and carbon monoxide, oxygen, fluorine, argon or methane having a boiling point at or lower than nitrogen is required. Then, evacuation rate sufficient for gases other than hydrogen gas can be obtained. (I.S.)

  16. Can-rupture detection in gas-cooled nuclear reactors; La detection des ruptures de gaine dans les piles nucleaires refroidies par gaz

    Energy Technology Data Exchange (ETDEWEB)

    Roguin, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    Can-rupture detection (DRG) is one important aspect of pile safety, more particularly so in the case of gas-cooled reactors. A rapid and sure detection constitutes also an improvement as far as the efficiency of electricity-producing nuclear power stations are concerned. Among the numerous can-rupture detection methods, that based on the measurement of the concentration of short-lived fission gases in the heat-carrying fluid has proved to be the most sensitive and the most rapid. A systematic study of detectors based on the electrostatic collection of the daughter products of fission gases has been undertaken with a view to equip the reactors EL 2, G 3, EDF 1, EDF 2 and EDF 3, the gas loops of PEGASE and EL 4. The different parameters are studied in detail in order to obtain a maximum sensitivity and to make it possible to construct detection devices having the maximum operational reliability and requiring the minimum maintenance. The primary applications of these devices are examined in the case of the above-mentioned reactors. (author) [French] La Detection des Ruptures de Gaines (D. R. G.) est un aspect important de la securite des piles et plus particulierement des piles refroidies par un gaz. Une detection rapide et sure constitue aussi un element d'amelioration du rendement des centrales nucleaires productrices d'energie electrique. Parmi les nombreuses methodes de detection des ruptures de gaines, la mesure de la concentration dans le fluide caloporteur des gaz de fission a vie courte s'est revelee comme la plus sensible et la plus rapide. Une etude systematique des detecteurs a collection electrostatique des descendants des gaz de fission a ete entreprise en vue d'equiper les piles EL 2, G 3, EDF 1, EDF 2 et EDF 3, les boucles a gaz de la pile Pegase et la pile EL 4. Les divers parametres sont etudies en detail pour obtenir une sensibilite maximum et permettre la realisation de dispositifs de detection ayant le maximum de securite de fonctionnement et le

  17. Can-rupture detection in gas-cooled nuclear reactors; La detection des ruptures de gaine dans les piles nucleaires refroidies par gaz

    Energy Technology Data Exchange (ETDEWEB)

    Roguin, A. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    Can-rupture detection (DRG) is one important aspect of pile safety, more particularly so in the case of gas-cooled reactors. A rapid and sure detection constitutes also an improvement as far as the efficiency of electricity-producing nuclear power stations are concerned. Among the numerous can-rupture detection methods, that based on the measurement of the concentration of short-lived fission gases in the heat-carrying fluid has proved to be the most sensitive and the most rapid. A systematic study of detectors based on the electrostatic collection of the daughter products of fission gases has been undertaken with a view to equip the reactors EL 2, G 3, EDF 1, EDF 2 and EDF 3, the gas loops of PEGASE and EL 4. The different parameters are studied in detail in order to obtain a maximum sensitivity and to make it possible to construct detection devices having the maximum operational reliability and requiring the minimum maintenance. The primary applications of these devices are examined in the case of the above-mentioned reactors. (author) [French] La Detection des Ruptures de Gaines (D. R. G.) est un aspect important de la securite des piles et plus particulierement des piles refroidies par un gaz. Une detection rapide et sure constitue aussi un element d'amelioration du rendement des centrales nucleaires productrices d'energie electrique. Parmi les nombreuses methodes de detection des ruptures de gaines, la mesure de la concentration dans le fluide caloporteur des gaz de fission a vie courte s'est revelee comme la plus sensible et la plus rapide. Une etude systematique des detecteurs a collection electrostatique des descendants des gaz de fission a ete entreprise en vue d'equiper les piles EL 2, G 3, EDF 1, EDF 2 et EDF 3, les boucles a gaz de la pile Pegase et la pile EL 4. Les divers parametres sont etudies en detail pour obtenir une sensibilite maximum et permettre la realisation de dispositifs de detection ayant le maximum de securite de

  18. High gain gas microstrip detectors for soft x-ray detection

    International Nuclear Information System (INIS)

    Bateman, J.; Barlow, R.; Derbyshire, G.

    2001-01-01

    This report describes development work in which systematic changes in the pitch of the electrode pattern of a Gas Microstrip Detector are explored in the search for higher avalanche gains and enhanced stability. With the cathode width set to half of the pitch, gas gains of >50 000 are comfortably attainable with low detector noise so that x-rays can potentially be detected down to the limit of a single x-ray-produced photoelectron. (author)

  19. Carbon nanotubes for gas detection: materials preparation and device assembly

    International Nuclear Information System (INIS)

    Terranova, M L; Lucci, M; Orlanducci, S; Tamburri, E; Sessa, V; Reale, A; Carlo, A Di

    2007-01-01

    An efficient sensing device for NH 3 and NO x detection has been realized using ordered arrays of single-walled C nanotubes deposited onto an interdigitated electrode platform operating at room temperature. The sensing material has been prepared using several chemical-physical techniques for purification and positioning of the nanotubes inside the electrode gaps. In particular, both DC and AC fields have been applied in order to move and to align the nanostructures by electrophoresis and dielectrophoresis processes. We investigated the effects of different voltages applied to a gate contact on the back side of the substrate on the performances of the device and found that for different gas species (NH 3 , NO x ) a constant gate bias increases the sensitivity for gas detection. Moreover, in this paper we demonstrate that a pulsed bias applied to the gate contact facilitates the gas interaction with the nanotubes, either reducing the absorption times or accelerating the desorption times, thus providing a fast acceleration and a dramatic improvement of the time dependent behaviour of the device

  20. Neonatal blood gas sampling methods | Goenka | South African ...

    African Journals Online (AJOL)

    There is little published guidance that systematically evaluates the different methods of neonatal blood gas sampling, where each method has its individual benefits and risks. This review critically surveys the available evidence to generate a comparison between arterial and capillary blood gas sampling, focusing on their ...

  1. Method of determining the depth of gas entry into the lifter of a gas lift well

    Energy Technology Data Exchange (ETDEWEB)

    Mishalov, N F; Popov, V A

    1981-01-01

    A method is proposed for determining the depth of gas entry into the lifter of a gas lift well, based on the data for measuring downhole and effective pressures. The method is used when analyzing and selecting operating conditions for gas lift wells at the Pravdinsk field.

  2. Leak detection technologies for oil and gas pipelines; Tecnologias para deteccao e localizacao de vazamento em dutos de oleo e ou gas

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, Julio R. [MTT Aselco Automacao Ltda., Sao Paulo, SP (Brazil)

    2005-07-01

    Two concepts are available for leak detection in oil and/or gas pipelines: On-line leak detection system and off-line leak detection technique. The off-line leak detection technique is, usually, portable and does net configure a 'system'. This technique includes hydro-test, acoustic emission of high frequency, tracer of chemical substances, ultrasonic flow meter (UT), thermographic infra-red mapping, electromagnetic offset registration, etc. Since most of those methods requests stop of the system or depend on direct and detailed inspection of the whole monitored piping they are limited to the off-line inspection. In the current days there are only two technologies applied to detect and locate leaks on-line: The acoustic Leak Detection System and the modeling of computerized simulation also called as RTM (Real Time Modeling), RTTM or Mass Balance. There are still other techniques in the market, as acoustic emission, pressure analysis (PPA) beyond other rough techniques, without good results. Even some of these techniques are working without success, they are still used to accomplish with government standards. (author)

  3. Detection of gas in landfills using resistivity measurements; Detektering av gas i deponier med resistivitet

    Energy Technology Data Exchange (ETDEWEB)

    Rosqvist, Haakan; Leroux, Virginie; Lindsjoe, Magnus (NSR AB, Helsingborg (Sweden)); Dahlin, Torleif (Lund Univ., LTH (Sweden)); Svensson, Mats; Maansson, Carl-Henrik (Tyrens AB, Stockholm (Sweden))

    2009-05-15

    The main objective with the research project was to develop a methodology to improve the understanding of landfill gas migration in landfills, based on measurements with electrical resistivity. Consequently, the project aimed at an improvement of the utilisation of the energy potential in landfill gas, and to reduce the environmental impact to the atmosphere. Further more, the objective was to improve techniques for investigations of internal structures in landfills. The project also aimed at better understanding of gas migration in the waste body and the mitigation through a landfill cover. Measurements were performed at four landfills; the Biocell reactor (NSR, Helsingborg), the Filborna landfill (NSR, Helsingborg), the Hyllstofta landfill (Naarab, Klippan) and the Flishult landfill (Vetab, Vetlanda). Three dimensional (3D) measurements and analysis were performed. The measurements were repeated in time in order to study changes with time for the resistivity. Supplementary information was created by measurement of other parameters, such as, groundwater table and soil temperature. The results from the resistivity measurements agreed with previous measurements performed at landfills, and thus, the results are therefore regarded as reliable. The measurements showed large temporal and spatial variations, and all of the measurements showed the highest variability near the surface. The results show that the resistivity technique is a powerful tool for investigations of the internal of landfills. Water and gas migration are important features in landfill management and both processes can be detected by using resistivity. Degradation of organic waste results in process with high variability in time and space. Also the degradation rate varies in a landfill and high variability was registered during the resistivity measurements. The high variability in resistivity is likely to be explained by changes in gas pressure and thus indicating gas migration. Therefore, the project

  4. Normal-Gamma-Bernoulli Peak Detection for Analysis of Comprehensive Two-Dimensional Gas Chromatography Mass Spectrometry Data.

    Science.gov (United States)

    Kim, Seongho; Jang, Hyejeong; Koo, Imhoi; Lee, Joohyoung; Zhang, Xiang

    2017-01-01

    Compared to other analytical platforms, comprehensive two-dimensional gas chromatography coupled with mass spectrometry (GC×GC-MS) has much increased separation power for analysis of complex samples and thus is increasingly used in metabolomics for biomarker discovery. However, accurate peak detection remains a bottleneck for wide applications of GC×GC-MS. Therefore, the normal-exponential-Bernoulli (NEB) model is generalized by gamma distribution and a new peak detection algorithm using the normal-gamma-Bernoulli (NGB) model is developed. Unlike the NEB model, the NGB model has no closed-form analytical solution, hampering its practical use in peak detection. To circumvent this difficulty, three numerical approaches, which are fast Fourier transform (FFT), the first-order and the second-order delta methods (D1 and D2), are introduced. The applications to simulated data and two real GC×GC-MS data sets show that the NGB-D1 method performs the best in terms of both computational expense and peak detection performance.

  5. Mixed gamma emitting gas standard and method

    International Nuclear Information System (INIS)

    McFarland, R.C.; McFarland, P.A.

    1986-01-01

    The invention in one aspect pertains to a method of calibrating gamma spectroscopy systems for gas counting in a variety of counting containers comprising withdrawing a precision volume of a mixed gamma-emitting gas standard from a precision volume vial and delivering the withdrawn precision volume of the gas standard to the interior of a gas counting container. Another aspect of the invention pertains to a mixed gamma-emitting gas standard, comprising a precision spherical vial of predetermined volume, multiple mixed emitting gas components enclosed within the vial, and means for withdrawing from the vial a predetermined amount of the components wherein the gas standard is used to calibrate a gamma spectrometer system for gas counting over a wide energy range without the use of additional standards. A third aspect comprehends a gamma spectrometer calibration system for gas counting, comprising a precision volume spherical glass vial for receiving mixed multiisotope gas components, and two tubular arms extending from the vial. A ground glass stopcock is positioned on each arm, and the outer end of one arm is provided with a rubber septum port

  6. Method and apparatus for preventing overspeed in a gas turbine

    Science.gov (United States)

    Walker, William E.

    1976-01-01

    A method and apparatus for preventing overspeed in a gas turbine in response to the rapid loss of applied load is disclosed. The method involves diverting gas from the inlet of the turbine, bypassing the same around the turbine and thereafter injecting the diverted gas at the turbine exit in a direction toward or opposing the flow of gas through the turbine. The injected gas is mixed with the gas exiting the turbine to thereby minimize the thermal shock upon equipment downstream of the turbine exit.

  7. Method for improved gas-solids separation

    Science.gov (United States)

    Kusik, C.L.; He, B.X.

    1990-11-13

    Methods are disclosed for the removal of particulate solids from a gas stream at high separation efficiency, including the removal of submicron size particles. The apparatus includes a cyclone separator type of device which contains an axially mounted perforated cylindrical hollow rotor. The rotor is rotated at high velocity in the same direction as the flow of an input particle-laden gas stream to thereby cause enhanced separation of particulate matter from the gas stream in the cylindrical annular space between the rotor and the sidewall of the cyclone vessel. Substantially particle-free gas passes through the perforated surface of the spinning rotor and into the hollow rotor, from where it is discharged out of the top of the apparatus. Separated particulates are removed from the bottom of the vessel. 4 figs.

  8. Measurement method for benzene, toluene, and xylene in the atmosphere by the gas chromatographic method

    Energy Technology Data Exchange (ETDEWEB)

    Shiroyama, H

    1975-08-01

    The chromatographic method for measuring benzene, toluene, and xylene (three isomers) in the atmosphere was evaluated using the Varian model 2740-10 gas chromatograph. As a solvent, n-hexane was most suitable, and the detection limit was improved by increasing the purity of n-hexane. The calibration curves were prepared, the recovery rate was calculated (76.0-99.4 percent), and the correlation coefficient was obtained from regression curves (r equals 0.97-0.99). Samples collected at a naphtha cracking plant, an aluminum smelting mill, a pharmaceutical plant, a carbon electrode manufacturing plant, a plywood manufacturing plant, a plastic bathtub manufacturing plant, and along a major highway were analyzed. All three substances were detected in all samples with the concentration of toluene high compared to the other two. Among xylene isomers, the concentration of p-xylene was always the lowest while m- and o-xylene varied from place to place. In the atmosphere along the highway, the benzene, toluene, and xylene determined were 0.01-0.09 ppM. No benzene, toluene, and xylene were detected in atmospheric samples used as controls.

  9. Resonant optical transducers for in-situ gas detection

    Science.gov (United States)

    Bond, Tiziana C; Cole, Garrett; Goddard, Lynford

    2016-06-28

    Configurations for in-situ gas detection are provided, and include miniaturized photonic devices, low-optical-loss, guided-wave structures and state-selective adsorption coatings. High quality factor semiconductor resonators have been demonstrated in different configurations, such as micro-disks, micro-rings, micro-toroids, and photonic crystals with the properties of very narrow NIR transmission bands and sensitivity up to 10.sup.-9 (change in complex refractive index). The devices are therefore highly sensitive to changes in optical properties to the device parameters and can be tunable to the absorption of the chemical species of interest. Appropriate coatings applied to the device enhance state-specific molecular detection.

  10. Resonant optical transducers for in-situ gas detection

    Energy Technology Data Exchange (ETDEWEB)

    Bond, Tiziana C.; Cole, Garrett; Goddard, Lynford

    2018-01-30

    Configurations for in-situ gas detection are provided, and include miniaturized photonic devices, low-optical-loss, guided-wave structures and state-selective adsorption coatings. High quality factor semiconductor resonators have been demonstrated in different configurations, such as micro-disks, micro-rings, micro-toroids, and photonic crystals with the properties of very narrow NIR transmission bands and sensitivity up to 10.sup.-9 (change in complex refractive index). The devices are therefore highly sensitive to changes in optical properties to the device parameters and can be tunable to the absorption of the chemical species of interest. Appropriate coatings applied to the device enhance state-specific molecular detection.

  11. Intercomparisons to establish official methods for the detection of irradiated foods

    International Nuclear Information System (INIS)

    Spiegelberg, A.; Schulzki, G.; Bogl, K.W.; Schreiber, G.A.

    1994-01-01

    Irradiation of food for the purpose of extension of shelf life, control of microbial load, reduction of pathogenic microorganisms and disinfection is considered by many consumers with suspicion. Our studies concentrate on the establishment of official methods suitable for routine control measurements. Special emphasis is given to following methods: thermoluminescence (TL) analysis of minerals isolated from various foods, like spices, herbs, dried vegetables, teas, fruits or vegetables; electron spin resonance (ESR) spectroscopy of food components or whole foods that have a low water content, such as bones, first bones, shells, peels seeds, pips or dried fruits and detection of volatile hydrocarbons in the lipid fraction of fat containing food by gas-chromatographic analysis (GC). All three methods have been tested on a variety of foods within large scale intercomparisons between German food controlling laboratories. In Germany official methods could be established for detection of irradiated spices, spice mixtures and fruits by TL, of meat with bones, nuts and fish by ESR, and of chicken, pork and beef meat by GC. The latest intercomparisons have tested these methods for the detection of potatoes and shrimps by TL, of red paper and shrimps by ESR and of mangoes, papayas, avocados and cheese - by GC. Results were presented. (author)

  12. Consideration on developing of leaked inflammable gas detection system for HTGR hydrogen production system

    International Nuclear Information System (INIS)

    Nishihara, Tetsuo; Nakamura, Masashi

    1999-09-01

    One of most important safety design issues for High Temperature Gas-cooled Reactor (HTGR) - Hydrogen Production System (HTGR-HPS) is to ensure reactor safety against fire and explosion at the hydrogen production plant. The inflammable gas mixture in the HTGR-HPS does not use oxygen in any condition and are kept in high pressure in the normal operation. The piping system and/or heat transfer tubes which have the potential possibility of combustible materials ingress into the Reactor Building (R/B) due to the failure are designed to prevent the failure against any events. Then, it is not necessary to consider their self-combustion in vessels nor leakage in the R/B. The only one case which we must consider is the ex-building fire or explosion caused by their leakage from piping or vessel. And it is important to mitigate their effects by means of early detection of gas leakage. We investigated our domestic standards on gas detection, applications of gas detectors, their detection principles, performance, sensitivity, reliability, their technical trends, and so on. We proposed three gas detection systems which may be applied in HTGR-HPS. The first one is the universal solid sensor system; it may be applied when there is no necessity to request their safety credits. The second is the combination of the improved solid sensor system and enhanced beam detector system; it may be applied when it is necessary to request their safety credit. And the third is the combination of the universal solid sensor system and the existing beam detector system; it may be applied when the plant owner request higher detector sensitivity than usual, from the view point of public acceptance, though there is not necessity to request their safety credits. To reduce the plant cost by refusing of safety credits to the gas leakage detection system, we proposed that the equipment required to isolate from others should be installed in the inertrized compartments. (author)

  13. Supercompressibility factor program. A new calculation method for real gas factors developed by the American Gas Association/Gas Research Institute

    Energy Technology Data Exchange (ETDEWEB)

    Luebbe, D.

    1987-07-01

    The innovative US calculation method for natural gas real gas factors is applicable to great pressure and temperature ranges and does not involve any restrictions as to the quality of natural gas. The results obtained for natural gas coming from Northern Germany or for imported natural gas are well consistent with actual measuring results. The model can therefore be applied as a rule for computing in a new technical recommendation and determine real gas factors whenever they are relevant to trading. The respective calculations must be preceded by a complete analysis characterizing the quality of gases. However, the new method allows for the alternative calculation of real gas factors on the basis of a small number of easily measurable factors (for example H/sub 0/, d, CO/sub 2/). This quality seams to be all the more attractive as it allows for an automatic translation of parametric sets at changing gas qualities which for the first time can manage without an expensive online gas chromatography or density translators, respectively.

  14. A Gas Cell Based on Hollow-Core Photonic Crystal Fiber (PCF and Its Application for the Detection of Greenhouse Gas (GHG: Nitrous Oxide (N2O

    Directory of Open Access Journals (Sweden)

    Jonas K. Valiunas

    2016-01-01

    Full Text Available The authors report the detection of nitrous oxide gas using intracavity fiber laser absorption spectroscopy. A gas cell based on a hollow-core photonic crystal fiber was constructed and used inside a fiber ring laser cavity as an intracavity gas cell. The fiber laser in the 1.55 μm band was developed using a polarization-maintaining erbium-doped fiber as the gain medium. The wavelength of the laser was selected by a fiber Bragg grating (FBG, and it matches one of the absorption lines of the gas under investigation. The laser wavelength contained multilongitudinal modes, which increases the sensitivity of the detection system. N2O gas has overtones of the fundamental absorption bands and rovibrational transitions in the 1.55 μm band. The system was operated at room temperature and was capable of detecting nitrous oxide gas at sub-ppmv concentration level.

  15. Improvement of gas entrainment prediction method. Introduction of surface tension effect

    International Nuclear Information System (INIS)

    Ito, Kei; Sakai, Takaaki; Ohshima, Hiroyuki; Uchibori, Akihiro; Eguchi, Yuzuru; Monji, Hideaki; Xu, Yongze

    2010-01-01

    A gas entrainment (GE) prediction method has been developed to establish design criteria for the large-scale sodium-cooled fast reactor (JSFR) systems. The prototype of the GE prediction method was already confirmed to give reasonable gas core lengths by simple calculation procedures. However, for simplification, the surface tension effects were neglected. In this paper, the evaluation accuracy of gas core lengths is improved by introducing the surface tension effects into the prototype GE prediction method. First, the mechanical balance between gravitational, centrifugal, and surface tension forces is considered. Then, the shape of a gas core tip is approximated by a quadratic function. Finally, using the approximated gas core shape, the authors determine the gas core length satisfying the mechanical balance. This improved GE prediction method is validated by analyzing the gas core lengths observed in simple experiments. Results show that the analytical gas core lengths calculated by the improved GE prediction method become shorter in comparison to the prototype GE prediction method, and are in good agreement with the experimental data. In addition, the experimental data under different temperature and surfactant concentration conditions are reproduced by the improved GE prediction method. (author)

  16. A rapid detection method for policy-sensitive amines real-time supervision.

    Science.gov (United States)

    Zhang, Haixu; Shu, Jinian; Yang, Bo; Zhang, Peng; Ma, Pengkun

    2018-02-01

    Many organic amines that comprise a benzene ring are policy-sensitive because of their toxicity and links to social harm. However, to date, detection of such compounds mainly relies on offline methods. This study proposes an online pptv (parts per trillion by volume) level of detection method for amines, using the recently-built vacuum ultraviolet photoionization mass spectrometer (VUV-PIMS) combined with a new doping technique. Thus, the dichloromethane doping-assisted photoionization mass spectra of aniline, benzylamine, phenethylamine, amphetamine, and their structural isomers were recorded. The dominant characteristic mass peaks for all amines are those afforded by protonated amines and the amino radical-loss. The signal intensities of the amines were enhanced by 60-130 times compared to those recorded without doping assistance. Under 10s detection time, the sensitivities of aniline and benzylamine in the gas phase were determined as 4.0 and 2.7 countspptv -1 , with limits of detection (LODs) of 36 and 22 pptv, respectively. Notably, the detection efficiency of this method can be tenfold better in future applications since the ion transmission efficiency of the mass spectrometer was intentionally reduced to ~ 10% in this study. Therefore, dichloromethane doping-assisted photoionization mass spectrometry has proven to be a highly promising on-line approach to amine detection in environmental and judicial supervision and shows great potential for application in the biological field. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Determination of sulfur dioxide in wine using headspace gas chromatography and electron capture detection.

    Science.gov (United States)

    Aberl, A; Coelhan, M

    2013-01-01

    Sulfites are routinely added as preservatives and antioxidants in wine production. By law, the total sulfur dioxide content in wine is restricted and therefore must be monitored. Currently, the method of choice for determining the total content of sulfur dioxide in wine is the optimised Monier-Williams method, which is time consuming and laborious. The headspace gas chromatographic method described in this study offers a fast and reliable alternative method for the detection and quantification of the sulfur dioxide content in wine. The analysis was performed using an automatic headspace injection sampler, coupled with a gas chromatograph and an electron capture detector. The method is based on the formation of gaseous sulfur dioxide subsequent to acidification and heating of the sample. In addition to free sulfur dioxide, reversibly bound sulfur dioxide in carbonyl compounds, such as acetaldehyde, was also measured with this method. A total of 20 wine samples produced using diverse grape varieties and vintages of varied provenance were analysed using the new method. For reference and comparison purposes, 10 of the results obtained by the proposed method were compared with those acquired by the optimised Monier-Williams method. Overall, the results from the headspace analysis showed good correlation (R = 0.9985) when compared with the conventional method. This new method requires minimal sample preparation and is simple to perform, and the analysis can also be completed within a short period of time.

  18. Naturally fractured tight gas: Gas reservoir detection optimization. Quarterly report, January 1--March 31, 1997

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-31

    Economically viable natural gas production from the low permeability Mesaverde Formation in the Piceance Basin, Colorado requires the presence of an intense set of open natural fractures. Establishing the regional presence and specific location of such natural fractures is the highest priority exploration goal in the Piceance and other western US tight, gas-centered basins. Recently, Advanced Resources International, Inc. (ARI) completed a field program at Rulison Field, Piceance Basin, to test and demonstrate the use of advanced seismic methods to locate and characterize natural fractures. This project began with a comprehensive review of the tectonic history, state of stress and fracture genesis of the basin. A high resolution aeromagnetic survey, interpreted satellite and SLAR imagery, and 400 line miles of 2-D seismic provided the foundation for the structural interpretation. The central feature of the program was the 4.5 square mile multi-azimuth 3-D seismic P-wave survey to locate natural fracture anomalies. The interpreted seismic attributes are being tested against a control data set of 27 wells. Additional wells are currently being drilled at Rulison, on close 40 acre spacings, to establish the productivity from the seismically observed fracture anomalies. A similar regional prospecting and seismic program is being considered for another part of the basin. The preliminary results indicate that detailed mapping of fault geometries and use of azimuthally defined seismic attributes exhibit close correlation with high productivity gas wells. The performance of the ten new wells, being drilled in the seismic grid in late 1996 and early 1997, will help demonstrate the reliability of this natural fracture detection and mapping technology.

  19. RPC gas recovery by open loop method

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Avinash [Alpha Pneumatics, 11, Krishna Kutir, Madanlal Dhigra Road, Panch Pakhadi (India)], E-mail: alpha_pneumatics@hotmail.com

    2009-05-01

    RPC detectors require to be flushed with small but continuous flow of gas mixture. Dealing with large number of detectors, gas consumption to very large volumes. Gas flow is a running expense and constituent gases are too expensive to be treated as consumables. Exhaust gas mixture from detectors is a potential environmental hazard if discharged directly into the atmosphere. Storage of gases on a large scale also leads to inventory- and safety-related problems. A solution to these problems is the recovery and reuse of exhaust gas mixture from RPC detectors. Close loop method employs recirculation of exhausted gas mixture after purification, analysis and addition of top-up quantities. In open loop method, under consideration here, individual component gases are separated from gas mixture and reused as source. During open loop process, gases liquefiable at low pressures are separated from ones liquefiable at high pressure. The gas phase components within each group are successively separated by either fractional condensation or gravity separation. Gas mixture coming from RPC exhaust is first desiccated by passage through molecular sieve adsorbent type (3A+4A). Subsequent scrubbing over basic activated alumina removes toxic and acidic contaminants such as S{sub 2}F{sub 10} produced during corona (arcing) discharge. In the first stage of separation isobutane and freon are concentrated by diffusion and liquefied by fractional condensation by cooling upto -30 deg. C. Liquefied gases are returned to source tanks. In the second stage of separation, argon and sulphur hexafluoride, the residual gases, are concentrated by settling due to density difference. SF{sub 6} is stored for recovery by condensation at high pressure while argon is further purified by thermal cracking of crossover impurities at 1000 deg. C followed by wet scrubbing.

  20. RPC gas recovery by open loop method

    International Nuclear Information System (INIS)

    Joshi, Avinash

    2009-01-01

    RPC detectors require to be flushed with small but continuous flow of gas mixture. Dealing with large number of detectors, gas consumption to very large volumes. Gas flow is a running expense and constituent gases are too expensive to be treated as consumables. Exhaust gas mixture from detectors is a potential environmental hazard if discharged directly into the atmosphere. Storage of gases on a large scale also leads to inventory- and safety-related problems. A solution to these problems is the recovery and reuse of exhaust gas mixture from RPC detectors. Close loop method employs recirculation of exhausted gas mixture after purification, analysis and addition of top-up quantities. In open loop method, under consideration here, individual component gases are separated from gas mixture and reused as source. During open loop process, gases liquefiable at low pressures are separated from ones liquefiable at high pressure. The gas phase components within each group are successively separated by either fractional condensation or gravity separation. Gas mixture coming from RPC exhaust is first desiccated by passage through molecular sieve adsorbent type (3A+4A). Subsequent scrubbing over basic activated alumina removes toxic and acidic contaminants such as S 2 F 10 produced during corona (arcing) discharge. In the first stage of separation isobutane and freon are concentrated by diffusion and liquefied by fractional condensation by cooling upto -30 deg. C. Liquefied gases are returned to source tanks. In the second stage of separation, argon and sulphur hexafluoride, the residual gases, are concentrated by settling due to density difference. SF 6 is stored for recovery by condensation at high pressure while argon is further purified by thermal cracking of crossover impurities at 1000 deg. C followed by wet scrubbing.

  1. On-line fast response device and method for measuring dissolved gas in a fluid

    Science.gov (United States)

    Tutu, Narinder Kumar [Manorville, NY

    2011-01-11

    A method and device for the measurement of dissolved gas within a fluid. The fluid, substantially a liquid, is pumped into a pipe. The flow of the fluid is temporally restricted, creating one or more low pressure regions. A measurement indicative of trapped air is taken before and after the restriction. The amount of dissolved air is calculated from the difference between the first and second measurements. Preferably measurements indicative of trapped air is obtained from one or more pressure transducers, capacitance transducers, or combinations thereof. In the alternative, other methods such as those utilizing x-rays or gamma rays may also be used to detect trapped air. Preferably, the fluid is a hydraulic fluid, whereby dissolved air in the fluid is detected.

  2. Application of gas-coupled laser acoustic detection to gelatins and underwater sensing

    International Nuclear Information System (INIS)

    Caron, James N.; Kunapareddy, Pratima

    2014-01-01

    Gas-coupled Laser Acoustic Detection (GCLAD) has been used as a method to sense ultrasound waves in materials without contact of the material surface. To sense the waveform, a laser beam is directed parallel to the material surface and displaced or deflected when the radiated waveform traverses the beam. We present recent tests that demonstrate the potential of using this technique for detecting ultrasound in gelatin phantoms and in water. As opposed to interferometric detection, GCLAD operates independently of the optical surface properties of the material. This allows the technique to be used in cases where the material is transparent or semi-transparent. We present results on sensing ultrasound in gelatin phantoms that are used to mimic biological materials. As with air-coupled transducers, the frequency response of GCLAD at high frequencies is limited by the high attenuation of ultrasound in air. In contrast, water has a much lower attenuation. Here we demonstrate the use of a GCLAD-like system in water, measuring the directivity response at 1 MHz and sensing waveforms with higher frequency content

  3. Proseek single-plex protein assay kit system to detect sAxl and Gas6 in serological material of brain tumor patients

    Directory of Open Access Journals (Sweden)

    Heidi Jaksch-Bogensperger

    2018-06-01

    Full Text Available • The receptor tyrosine kinase (RTK Axl and its ligand Gas6 are critically involved in the pathogenesis of high-grade glioma (HGG. Both proteins were found to be overexpressed e.g. in tumor cells, mediating cell proliferation and migration as well as tumor angiogenesis and neuroinflammation. The extracellular domain of Axl (sAxl and Gas6 were found in the peri-tumoral edema and blood of animals as well as in human glioma tissue. Therefore, we monitored the level of sAxl and Gas6 in human blood samples. To increase the sensitivity of protein detection beyond commonly used standard methods we preliminary tested the innovative Proseek Single-Plex Protein Assay Kit System from Olink Bioscience together with new antibodies against the soluble RTK sAxl and its ligand Gas6. We conclude that the Proseek method is a highly sensitive and fast procedure that can be used as a possible powerful tool compared to routinely used ELISA-methods.

  4. High Altitude Aerial Natural Gas Leak Detection System

    Energy Technology Data Exchange (ETDEWEB)

    Richard T. Wainner; Mickey B. Frish; B. David Green; Matthew C. Laderer; Mark G. Allen; Joseph R. Morency

    2006-12-31

    The objective of this program was to develop and demonstrate a cost-effective and power-efficient advanced standoff sensing technology able to detect and quantify, from a high-altitude (> 10,000 ft) aircraft, natural gas leaking from a high-pressure pipeline. The advanced technology is based on an enhanced version of the Remote Methane Leak Detector (RMLD) platform developed previously by Physical Sciences Inc. (PSI). The RMLD combines a telecommunications-style diode laser, fiber-optic components, and low-cost DSP electronics with the well-understood principles of Wavelength Modulation Spectroscopy (WMS), to indicate the presence of natural gas located between the operator and a topographic target. The transceiver transmits a laser beam onto a topographic target and receives some of the laser light reflected by the target. The controller processes the received light signal to deduce the amount of methane in the laser's path. For use in the airborne platform, we modified three aspects of the RMLD, by: (1) inserting an Erbium-doped optical fiber laser amplifier to increase the transmitted laser power from 10 mW to 5W; (2) increasing the optical receiver diameter from 10 cm to 25 cm; and (3) altering the laser wavelength from 1653 nm to 1618 nm. The modified RMLD system provides a path-integrated methane concentration sensitivity {approx}5000 ppm-m, sufficient to detect the presence of a leak from a high capacity transmission line while discriminating against attenuation by ambient methane. In ground-based simulations of the aerial leak detection scenario, we demonstrated the ability to measure methane leaks within the laser beam path when it illuminates a topographic target 2000 m away. We also demonstrated simulated leak detection from ranges of 200 m using the 25 cm optical receiver without the fiber amplifier.

  5. Analytical method validation of GC-FID for the simultaneous measurement of hydrocarbons (C2-C4 in their gas mixture

    Directory of Open Access Journals (Sweden)

    Oman Zuas

    2016-09-01

    Full Text Available An accurate gas chromatography coupled to a flame ionization detector (GC-FID method was validated for the simultaneous analysis of light hydrocarbons (C2-C4 in their gas mixture. The validation parameters were evaluated based on the ISO/IEC 17025 definition including method selectivity, repeatability, accuracy, linearity, limit of detection (LOD, limit of quantitation (LOQ, and ruggedness. Under the optimum analytical conditions, the analysis of gas mixture revealed that each target component was well-separated with high selectivity property. The method was also found to be precise and accurate. The method linearity was found to be high with good correlation coefficient values (R2 ≥ 0.999 for all target components. It can be concluded that the GC-FID developed method is reliable and suitable for determination of light C2-C4 hydrocarbons (including ethylene, propane, propylene, isobutane, and n-butane in their gas mixture. The validated method has successfully been applied to the estimation of hydrocarbons light C2-C4 hydrocarbons in natural gas samples, showing high performance repeatability with relative standard deviation (RSD less than 1.0% and good selectivity with no interference from other possible components could be observed.

  6. Method of separating radioactive krypton gas

    International Nuclear Information System (INIS)

    Kimura, Shigeru; Awada, Yoshihisa.

    1975-01-01

    Object: To effectively and safely separate and recover Kr-85, which requires a long storage period for attenuating radioactivity, from a mixture gas consisting of Kr-85 and Xe by a liquefaction distillation method. Structure: A mixture gas consisting of Kr and Xe is subjected to heat exchange in a cooler with Freon gas from a plurality of distillation towers for its temperature reduction from normal temperature to a lower temperature, and then it is supplied to a distillation tower. The distillation tower is held at a pressure above 15 ata, preferably around 20 ata, and a condenser provided at the top of the distillation tower is furnished with Freon as cooling medium. The rare mixture gas is distilled by liquefaction within a distillation tower, and Kr-85 is obtained from a top duct while obtaining Xe from a bottom duct. Xe after separation by liquefaction is returned to a rare mixture gas supply inlet of a liquefaction distillation means for repeated refinement in the distillation tower. (Kamimura, M.)

  7. Bootstrap inversion technique for atmospheric trace gas source detection and quantification using long open-path laser measurements

    Science.gov (United States)

    Alden, Caroline B.; Ghosh, Subhomoy; Coburn, Sean; Sweeney, Colm; Karion, Anna; Wright, Robert; Coddington, Ian; Rieker, Gregory B.; Prasad, Kuldeep

    2018-03-01

    Advances in natural gas extraction technology have led to increased activity in the production and transport sectors in the United States and, as a consequence, an increased need for reliable monitoring of methane leaks to the atmosphere. We present a statistical methodology in combination with an observing system for the detection and attribution of fugitive emissions of methane from distributed potential source location landscapes such as natural gas production sites. We measure long (> 500 m), integrated open-path concentrations of atmospheric methane using a dual frequency comb spectrometer and combine measurements with an atmospheric transport model to infer leak locations and strengths using a novel statistical method, the non-zero minimum bootstrap (NZMB). The new statistical method allows us to determine whether the empirical distribution of possible source strengths for a given location excludes zero. Using this information, we identify leaking source locations (i.e., natural gas wells) through rejection of the null hypothesis that the source is not leaking. The method is tested with a series of synthetic data inversions with varying measurement density and varying levels of model-data mismatch. It is also tested with field observations of (1) a non-leaking source location and (2) a source location where a controlled emission of 3.1 × 10-5 kg s-1 of methane gas is released over a period of several hours. This series of synthetic data tests and outdoor field observations using a controlled methane release demonstrates the viability of the approach for the detection and sizing of very small leaks of methane across large distances (4+ km2 in synthetic tests). The field tests demonstrate the ability to attribute small atmospheric enhancements of 17 ppb to the emitting source location against a background of combined atmospheric (e.g., background methane variability) and measurement uncertainty of 5 ppb (1σ), when measurements are averaged over 2 min. The

  8. Rapid, Real-time Methane Detection in Ground Water Using a New Gas-Water Equilibrator Design

    Science.gov (United States)

    Ruybal, C. J.; DiGiulio, D. C.; Wilkin, R. T.; Hargrove, K. D.; McCray, J. E.

    2014-12-01

    Recent increases in unconventional gas development have been accompanied by public concern for methane contamination in drinking water wells near production areas. Although not a regulated pollutant, methane may be a marker contaminant for others that are less mobile in groundwater and thus may be detected later, or at a location closer to the source. In addition, methane poses an explosion hazard if exsolved concentrations reach 5 - 15% volume in air. Methods for determining dissolved gases, such as methane, have evolved over 60 years. However, the response time of these methods is insufficient to monitor trends in methane concentration in real-time. To enable rapid, real-time monitoring of aqueous methane concentrations during ground water purging, a new gas-water equilibrator (GWE) was designed that increases gas-water mass exchange rates of methane for measurement. Monitoring of concentration trends allows a comparison of temporal trends between sampling events and comparison of baseline conditions with potential post-impact conditions. These trends may be a result of removal of stored casing water, pre-purge ambient borehole flow, formation physical and chemical heterogeneity, or flow outside of well casing due to inadequate seals. Real-time information in the field can help focus an investigation, aid in determining when to collect a sample, save money by limiting costs (e.g. analytical, sample transport and storage), and provide an immediate assessment of local methane concentrations. Four domestic water wells, one municipal water well, and one agricultural water well were sampled for traditional laboratory analysis and compared to the field GWE results. Aqueous concentrations measured on the GWE ranged from non-detect to 1,470 μg/L methane. Some trends in aqueous methane concentrations measured on the GWE were observed during purging. Applying a paired t-test comparing the new GWE method and traditional laboratory analysis yielded a p-value 0

  9. Contribution to the study of a new X-ray detection method for medical imaging

    International Nuclear Information System (INIS)

    Bouteiller, Patrick.

    1977-01-01

    The present work is part of a joint effort to develop a quick and efficient tomographic technique. Our research is devoted to the feasibility of a new detection method applicable to such apparatus with a view to the short- or medium-term industrial development of these techniques. Following an outline of the basic principles of this image reconstruction method the fundamental parameters governing the choice of detection system are defined. Part two gives results relating to the first solutions examined and to their limits and disadvantages from the viewpoint of a possible industrial application. Part three reports and justifies, both theoretically and experimentally, a choice of detection method using a high-pressure gas ionisation chamber. Part four describes our participation in the building of an industrial prototype and the additional problems encountered. The final part deals with possibilities of improving the system either by perfecting the above methods or after studies on new structures developed in the laboratory [fr

  10. Method for treating a nuclear process off-gas stream

    International Nuclear Information System (INIS)

    Pence, D.T.; Chou, C.-C.

    1981-01-01

    A method is described for selectively removing and recovering the noble gas and other gaseous components typically emitted during nuclear process operations. The method is useful for treating dissolver off-gas effluents released during reprocessing of spent nuclear fuels to permit radioactive contaminant recovery prior to releasing the remaining off-gases to the atmosphere. The method involves a sequence of adsorption and desorption steps which are specified. Particular reference is made to the separation of xenon and krypton from the off-gas stream, and to the use of silver-exchanged mordenite as the adsorbent. (U.K.)

  11. Validation of a method to determine methylmercury in fish tissues using gas chromatography

    International Nuclear Information System (INIS)

    Vega Bolannos, Luisa O.; Arias Verdes, Jose A.; Beltran Llerandi, Gilberto; Castro Diaz, Odalys; Moreno Tellez, Olga L.

    2000-01-01

    We validated a method to determine methylmercury in fish tissues using gas chromatography with an electron capture detector as described by the Association of Official Analytical Chemist (AOAC) International. The linear curve range was 0.02 to 1 g/ml and linear correlation coefficient was 0.9979. A 1 mg/kg methylmercury-contaminated fish sample was analyzed 20 times to determine repeatability of the method. The quantification limit was 0.16 mg/kg and detection limit was 0.06 ppm. Fish samples contaminated with 0.2 to 10 mg/kg methylmercury showed recovery indexes from 94.66 to 108.8%

  12. Novel top-contact monolayer pentacene-based thin-film transistor for ammonia gas detection.

    Science.gov (United States)

    Mirza, Misbah; Wang, Jiawei; Li, Dexing; Arabi, S Atika; Jiang, Chao

    2014-04-23

    We report on the fabrication of an organic field-effect transistor (OFET) of a monolayer pentacene thin film with top-contact electrodes for the aim of ammonia (NH3) gas detection by monitoring changes in its drain current. A top-contact configuration, in which source and drain electrodes on a flexible stamp [poly(dimethylsiloxane)] were directly contacted with the monolayer pentacene film, was applied to maintain pentacene arrangement ordering and enhance the monolayer OFET detection performance. After exposure to NH3 gas, the carrier mobility at the monolayer OFET channel decreased down to one-third of its original value, leading to a several orders of magnitude decrease in the drain current, which tremendously enhanced the gas detection sensitivity. This sensitivity enhancement to a limit of the 10 ppm level was attributed to an increase of charge trapping in the carrier channel, and the amount of trapped states was experimentally evaluated by the threshold voltage shift induced by the absorbed NH3 molecular analyte. In contrast, a conventional device with a 50-nm-thick pentacene layer displayed much higher mobility but lower response to NH3 gas, arising from the impediment of analyte penetrating into the conductive channel, owing to the thick pentacene film.

  13. Gas Flow Detection System

    Science.gov (United States)

    Moss, Thomas; Ihlefeld, Curtis; Slack, Barry

    2010-01-01

    This system provides a portable means to detect gas flow through a thin-walled tube without breaking into the tubing system. The flow detection system was specifically designed to detect flow through two parallel branches of a manifold with only one inlet and outlet, and is a means for verifying a space shuttle program requirement that saves time and reduces the risk of flight hardware damage compared to the current means of requirement verification. The prototype Purge Vent and Drain Window Cavity Conditioning System (PVD WCCS) Flow Detection System consists of a heater and a temperature-sensing thermistor attached to a piece of Velcro to be attached to each branch of a WCCS manifold for the duration of the requirement verification test. The heaters and thermistors are connected to a shielded cable and then to an electronics enclosure, which contains the power supplies, relays, and circuit board to provide power, signal conditioning, and control. The electronics enclosure is then connected to a commercial data acquisition box to provide analog to digital conversion as well as digital control. This data acquisition box is then connected to a commercial laptop running a custom application created using National Instruments LabVIEW. The operation of the PVD WCCS Flow Detection System consists of first attaching a heater/thermistor assembly to each of the two branches of one manifold while there is no flow through the manifold. Next, the software application running on the laptop is used to turn on the heaters and to monitor the manifold branch temperatures. When the system has reached thermal equilibrium, the software application s graphical user interface (GUI) will indicate that the branch temperatures are stable. The operator can then physically open the flow control valve to initiate the test flow of gaseous nitrogen (GN2) through the manifold. Next, the software user interface will be monitored for stable temperature indications when the system is again at

  14. Method for filtering radon from a gas system

    International Nuclear Information System (INIS)

    Sowinski, R.F.

    1992-01-01

    This patent describes a method of filtering, adjacent to an end user-customer's residence, or business in which at least a single gas appliance is located, a natural gas stream in which benz-a-anthracene has been concentrated at sufficient levels to be a health threat in a natural gas gathering and distributing network. It comprises introducing the natural gas stream to a filter selected from a group that includes impingement, passing the filtered natural gas stream to the customer's gas appliance wherein safe use of the energy associated with the stream occurs, periodically and safely removing the filter for disposing of captured benz-a-anthracene, inserting a new filter in place of the removed filter of step

  15. Comparing Natural Gas Leakage Detection Technologies Using an Open-Source "Virtual Gas Field" Simulator.

    Science.gov (United States)

    Kemp, Chandler E; Ravikumar, Arvind P; Brandt, Adam R

    2016-04-19

    We present a tool for modeling the performance of methane leak detection and repair programs that can be used to evaluate the effectiveness of detection technologies and proposed mitigation policies. The tool uses a two-state Markov model to simulate the evolution of methane leakage from an artificial natural gas field. Leaks are created stochastically, drawing from the current understanding of the frequency and size distributions at production facilities. Various leak detection and repair programs can be simulated to determine the rate at which each would identify and repair leaks. Integrating the methane leakage over time enables a meaningful comparison between technologies, using both economic and environmental metrics. We simulate four existing or proposed detection technologies: flame ionization detection, manual infrared camera, automated infrared drone, and distributed detectors. Comparing these four technologies, we found that over 80% of simulated leakage could be mitigated with a positive net present value, although the maximum benefit is realized by selectively targeting larger leaks. Our results show that low-cost leak detection programs can rely on high-cost technology, as long as it is applied in a way that allows for rapid detection of large leaks. Any strategy to reduce leakage should require a careful consideration of the differences between low-cost technologies and low-cost programs.

  16. Application of cholesterol determination method to indirectly detect meat and bone meals in ruminant feeds

    Directory of Open Access Journals (Sweden)

    Cecília M. Bandeira

    2013-01-01

    Full Text Available The aim of this study was to verify the presence of meat and bone meal (MBM in ruminant feed, by identifying the cholesterol using gas chromatography with a flame ionization detector. The proposed method demonstrated precision, trueness, and capability to detect MBM in the ruminant feed.

  17. Ethanol analysis by headspace gas chromatography with simultaneous flame-ionization and mass spectrometry detection.

    Science.gov (United States)

    Tiscione, Nicholas B; Alford, Ilene; Yeatman, Dustin Tate; Shan, Xiaoqin

    2011-09-01

    Ethanol is the most frequently identified compound in forensic toxicology. Although confirmation involving mass spectrometry is desirable, relatively few methods have been published to date. A novel technique utilizing a Dean's Switch to simultaneously quantitate and confirm ethyl alcohol by flame-ionization (FID) and mass spectrometric (MS) detection after headspace sampling and gas chromatographic separation is presented. Using 100 μL of sample, the limits of detection and quantitation were 0.005 and 0.010 g/dL, respectively. The zero-order linear range (r(2) > 0.990) was determined to span the concentrations of 0.010 to 1.000 g/dL. The coefficient of variation of replicate analyses was less than 3.1%. Quantitative accuracy was within ±8%, ±6%, ±3%, and ±1.5% at concentrations of 0.010, 0.025, 0.080, and 0.300 g/dL, respectively. In addition, 1,1-difluoroethane was validated for qualitative identification by this method. The validated FID-MS method provides a procedure for the quantitation of ethyl alcohol in blood by FID with simultaneous confirmation by MS and can also be utilized as an identification method for inhalants such as 1,1-difluoroethane.

  18. Detection of gas-permeable fuel particles for highl 7490 temperature gas-cooled reactors

    International Nuclear Information System (INIS)

    Thiele, B.A.; Stinton, D.P.; Costanzo, D.A.

    1980-01-01

    Fuel for High-Temperature Gas-Cooled Reactors (HTGR) consists of uranium oxide-carbide and thoria microspheres coated with layers of pyrolytic carbon and silicon carbide. The pyrolytic carbon coatings must be gas-tight to perform properly during irradiation. Therefore, particles must be carefully characterized to determine the number of defective particles (ie bare kernels, and cracked or permeable coatings). Although techniques are available to determine the number of bare kernels or cracked coatings, no reliable technique has been available to measure coating permeability. This work describes a technique recently developed to determine whether coatings for a batch of particles are gas-tight or permeable. Although most of this study was performed on Biso-coated particles, the technique applies equally well to Triso-coated particles. About 150 randomly selected Biso-particle batches were studied in this work. These batches were first subjected to an 18-hr chlorination at 15000C, and the volatile thorium tetrachloride released through cracked or very permeable coatings was measured versus chlorination time. Chlorinated batches were also radiographed to detect any thorium that had migrated from the kernel into the coatings. From this work a technique was developed to determine coating permeability. This consists of an 18-hr chlorination of multiple samples without measurement of the heavy metal released. Each batch is then radiographed and the heavy metal diffusion within each particle is examined so it can be determined if a particle batch is permeable, slightly permeable, or gas-tight. (author)

  19. Comparison of information content of temporal response of chemoresistive gas sensor under three different temperature modulation regimes for gas detection of different feature reduction methods

    Science.gov (United States)

    Hosseini-Golgoo, S. M.; Salimi, F.; Saberkari, A.; Rahbarpour, S.

    2017-12-01

    In the present work the feature extraction of transient response of a resistive gas sensor under temperature cycling, temperature transient, and temperature combination methods were compared. So, the heater were stimulated by three pulse (cycling), ramp (transient) and staircase (combination) waveforms. The period or duration of all waves was equal to 40 s. Methanol, ethanol, 1-propanol, 1-butanol, toluene and acetone each at 11 different concentration levels in the range of 100 to 2000 ppm were used as the target gases. The utilized sensor was TGS-813 that made by Figaro Company. Recorded results were studied and heuristic features such as peak, rise time, slope and curvature of recorded responses were extracted for each heater waveform. Results showed that although application of this feature extraction method to all waveforms led to gas diagnoses, best results were achieved in the case of staircase waveform. The combination waveform had enough information to separate all examined target gases.

  20. A combined approach based on MAF analysis and AHP method to fault detection mapping: A case study from a gas field, southwest of Iran

    Science.gov (United States)

    Shakiba, Sima; Asghari, Omid; Khah, Nasser Keshavarz Faraj

    2018-01-01

    A combined geostatitical methodology based on Min/Max Auto-correlation Factor (MAF) analysis and Analytical Hierarchy Process (AHP) is presented to generate a suitable Fault Detection Map (FDM) through seismic attributes. Five seismic attributes derived from a 2D time slice obtained from data related to a gas field located in southwest of Iran are used including instantaneous amplitude, similarity, energy, frequency, and Fault Enhancement Filter (FEF). The MAF analysis is implemented to reduce dimension of input variables, and then AHP method is applied on three obtained de-correlated MAF factors as evidential layer. Three Decision Makers (DMs) are used to construct PCMs for determining weights of selected evidential layer. Finally, weights obtained by AHP were multiplied in normalized valued of each alternative (MAF layers) and the concluded weighted layers were integrated in order to prepare final FDM. Results proved that applying algorithm proposed in this study generate a map more acceptable than the each individual attribute and sharpen the non-surface discontinuities as well as enhancing continuity of detected faults.

  1. Strategies for Detecting Hidden Geothermal Systems by Near-Surface Gas Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lewicki, Jennifer L.; Oldenburg, Curtis M.

    2004-12-15

    the near-surface environment include (1) the infrared gas analyzer (IRGA) for measurement of concentrations at point locations, (2) the accumulation chamber (AC) method for measuring soil CO2 fluxes at point locations, (3) the eddy covariance (EC) method for measuring net CO2 flux over a given area, (4) hyperspectral imaging of vegetative stress resulting from elevated CO2 concentrations, and (5) light detection and ranging (LIDAR) that can measure CO2 concentrations over an integrated path. Technologies currently in developmental stages that have the potential to be used for CO2 monitoring include tunable lasers for long distance integrated concentration measurements and micro-electronic mechanical systems (MEMS) that can make widespread point measurements. To address the challenge of detecting potentially small-magnitude geothermal CO2 emissions within the natural background variability of CO2, we propose an approach that integrates available detection and monitoring methodologies with statistical analysis and modeling strategies. Within the area targeted for geothermal exploration, point measurements of soil CO2 fluxes and concentrations using the AC method and a portable IRGA, respectively, and measurements of net surface flux using EC should be made. Also, the natural spatial and temporal variability of surface CO2 fluxes and subsurface CO2 concentrations should be quantified within a background area with similar geologic, climatic, and ecosystem characteristics to the area targeted for geothermal exploration. Statistical analyses of data collected from both areas should be used to guide sampling strategy, discern spatial patterns that may be indicative of geothermal CO2 emissions, and assess the presence (or absence) of geothermal CO2 within the natural background variability with a desired confidence level. Once measured CO2 concentrations and fluxes have been determined to be of anomalous geothermal origin with high confidence, more expensive vertical

  2. Monitoring methods of drift chamber characteristics. Application to SPES III detection

    International Nuclear Information System (INIS)

    Kerboul, C.

    1984-05-01

    For the SPES III spectrometer at the Laboratoire National Saturne, a large detection system has been developed which consists of three drift chambers for localization of the particle trajectories. Performances of these detectors for high spatial resolution depend greatly on different parameters such as anode current, gas mixture, drift velocity, efficiency, etc. The present work summarizes a set of methods necessary to the control of these parameters, for achieving the high resolution essentiel for the nuclear physic at intermediate energy [fr

  3. Detection of outliers by neural network on the gas centrifuge experimental data of isotopic separation process

    International Nuclear Information System (INIS)

    Andrade, Monica de Carvalho Vasconcelos

    2004-01-01

    This work presents and discusses the neural network technique aiming at the detection of outliers on a set of gas centrifuge isotope separation experimental data. In order to evaluate the application of this new technique, the result obtained of the detection is compared to the result of the statistical analysis combined with the cluster analysis. This method for the detection of outliers presents a considerable potential in the field of data analysis and it is at the same time easier and faster to use and requests very less knowledge of the physics involved in the process. This work established a procedure for detecting experiments which are suspect to contain gross errors inside a data set where the usual techniques for identification of these errors cannot be applied or its use/demands an excessively long work. (author)

  4. Double layer films based on TiO{sub 2} and NiO{sub x} for gas detection

    Energy Technology Data Exchange (ETDEWEB)

    Kosc, I., E-mail: ivan.kosc@stuba.sk [Institute of Electronics and Photonics, Slovak University of Technology, Bratislava (Slovakia); Hotovy, I. [Institute of Electronics and Photonics, Slovak University of Technology, Bratislava (Slovakia); Roch, T.; Plecenik, T.; Gregor, M. [Faculty of Mathematics, Physics and Informatics, Comenius University, Bratislava (Slovakia); Predanocy, M. [Institute of Electronics and Photonics, Slovak University of Technology, Bratislava (Slovakia); Cehlarova, M.; Kus, P.; Plecenik, A. [Faculty of Mathematics, Physics and Informatics, Comenius University, Bratislava (Slovakia)

    2014-09-01

    Highlights: • Double layer films based on TiO{sub 2} and NiO{sub x} for gas detection were studied. • Structural, compositional and morphological properties were investigated. • XPS spectra of TiO{sub 2} and NiO{sub x} were identified. • P- and n-type of response to hydrogen were presented. • Inversion of conductivity response type was confirmed. - Abstract: Double layer films based on TiO{sub 2} and NiO{sub x} for gas detection were studied. Two layouts with opposite position of functional films were deposited via DC magnetron sputtering method and annealed at 600 °C. The compositional, structural, morphological, electrical and gas sensing parameters were investigated. The depth profiles and the chemical state of the thin films elements were explored by X-ray photoelectron spectroscopy (XPS). Differences between the surface and subsurface NiO{sub x} were confirmed. In this way the formation of surface oxides and subsurface metallic Ni were observed. The structural changes and polycrystalline character were noticed by X-ray diffraction (XRD). The atomic force microscopy (AFM) revealed nanocrystalline character of the examined surfaces (both layouts). Different position of TiO{sub 2} and NiO{sub x} functional films brought difference in the type of response to reducing gas. Moreover, inversion of response type due to different H{sub 2} concentrations was confirmed.

  5. Tunable photonic cavities for in-situ spectroscopic trace gas detection

    Science.gov (United States)

    Bond, Tiziana; Cole, Garrett; Goddard, Lynford

    2012-11-13

    Compact tunable optical cavities are provided for in-situ NIR spectroscopy. MEMS-tunable VCSEL platforms represents a solid foundation for a new class of compact, sensitive and fiber compatible sensors for fieldable, real-time, multiplexed gas detection systems. Detection limits for gases with NIR cross-sections such as O.sub.2, CH.sub.4, CO.sub.x and NO.sub.x have been predicted to approximately span from 10.sup.ths to 10s of parts per million. Exemplary oxygen detection design and a process for 760 nm continuously tunable VCSELS is provided. This technology enables in-situ self-calibrating platforms with adaptive monitoring by exploiting Photonic FPGAs.

  6. Remote detection device and detection method therefor

    International Nuclear Information System (INIS)

    Kogure, Sumio; Yoshida, Yoji; Matsuo, Takashiro; Takehara, Hidetoshi; Kojima, Shinsaku.

    1997-01-01

    The present invention provides a non-destructive detection device for collectively, efficiently and effectively conducting maintenance and detection for confirming the integrity of a nuclear reactor by way of a shielding member for shielding radiation rays generated from an objective portion to be detected. Namely, devices for direct visual detection using an under water TV camera as a sensor, an eddy current detection using a coil as a sensor and each magnetic powder flow detection are integrated and applied collectively. Specifically, the visual detection by using the TV camera and the eddy current flaw detection are adopted together. The flaw detection with magnetic powder is applied as a means for confirming the results of the two kinds of detections by other method. With such procedures, detection techniques using respective specific theories are combined thereby enabling to enhance the accuracy for the evaluation of the detection. (I.S.)

  7. Application of geoelectric methods for man-caused gas deposit mapping and monitoring

    Science.gov (United States)

    Yakymchuk, M. A.; Levashov, S. P.; Korchagin, I. N.; Syniuk, B. B.

    2009-04-01

    The rather new application of original geoelectric methods of forming of short-pulsed electromagnetic field (FSPEF) and vertical electric-resonance sounding (VERS) (FSPEF-VERS technology) (Levashov et al., 2003; 2004) is discussed. In 2008 the FSPEF-VERS methods were used for ascertaining the reasons of serious man-caused accident on gas field. The emission of water with gas has occurred near an operational well on one gas field. The assumption was discussed, that some part of gas from producing horizons has got into the upper horizons, in aquiferous stratum layers. It promoted creation of superfluous pressure in aquiferous stratums which has led to accident on the field. Operative geophysical investigations within an accident site were carried out by FSPEF and VERS geoelectric methods on 07.10.08 and 13.10.08 on the first stage. The primary goal of executed works was detection and mapping of gas penetration zones in aquiferous stratums of cross-section upper part, and also the determination of bedding depths and a total area of distribution of gas in upper aquiferous stratums. The anomalous zone were revealed and mapped by FSPEF survey. It is caused by raised migration of water in upper horizons of a cross-section. The depths of anomalous polarized layers (APL) of "gas" and „aquiferous stratum" type were defined by VERS method. The VERS data are presented by sounding diagram's and columns, by vertical cross-sections lengthways and transversely of gas penetration zones, by map of thicknesses of man-caused gas "deposit". The perforation on depths of 450 and 310 m was spent in a producing borehole on the first day investigation data. Gas discharges were received from 450 and 310 m depths. Three degassing boreholes have been drilled on 08.11.08 working day. Depths of wells are about 340 m. Gas inflows were received from 330 m depth. Drilling of fourth well was conducted. The anomalous zone area has decreased twice in comparison with two previous surveys. So, the

  8. A validated method for the quantitation of 1,1-difluoroethane using a gas in equilibrium method of calibration.

    Science.gov (United States)

    Avella, Joseph; Lehrer, Michael; Zito, S William

    2008-10-01

    1,1-Difluoroethane (DFE), also known as Freon 152A, is a member of a class of compounds known as halogenated hydrocarbons. A number of these compounds have gained notoriety because of their ability to induce rapid onset of intoxication after inhalation exposure. Abuse of DFE has necessitated development of methods for its detection and quantitation in postmortem and human performance specimens. Furthermore, methodologies applicable to research studies are required as there have been limited toxicokinetic and toxicodynamic reports published on DFE. This paper describes a method for the quantitation of DFE using a gas chromatography-flame-ionization headspace technique that employs solventless standards for calibration. Two calibration curves using 0.5 mL whole blood calibrators which ranged from A: 0.225-1.350 to B: 9.0-180.0 mg/L were developed. These were evaluated for linearity (0.9992 and 0.9995), limit of detection of 0.018 mg/L, limit of quantitation of 0.099 mg/L (recovery 111.9%, CV 9.92%), and upper limit of linearity of 27,000.0 mg/L. Combined curve recovery results of a 98.0 mg/L DFE control that was prepared using an alternate technique was 102.2% with CV of 3.09%. No matrix interference was observed in DFE enriched blood, urine or brain specimens nor did analysis of variance detect any significant differences (alpha = 0.01) in the area under the curve of blood, urine or brain specimens at three identical DFE concentrations. The method is suitable for use in forensic laboratories because validation was performed on instrumentation routinely used in forensic labs and due to the ease with which the calibration range can be adjusted. Perhaps more importantly it is also useful for research oriented studies because the removal of solvent from standard preparation eliminates the possibility for solvent induced changes to the gas/liquid partitioning of DFE or chromatographic interference due to the presence of solvent in specimens.

  9. Identification of volatiles by headspace gas chromatography with simultaneous flame ionization and mass spectrometric detection.

    Science.gov (United States)

    Tiscione, Nicholas B; Yeatman, Dustin Tate; Shan, Xiaoqin; Kahl, Joseph H

    2013-10-01

    Volatiles are frequently abused as inhalants. The methods used for identification are generally nonspecific if analyzed concurrently with ethanol or require an additional analytical procedure that employs mass spectrometry. A previously published technique utilizing a capillary flow technology splitter to simultaneously quantitate and confirm ethyl alcohol by flame ionization and mass spectrometric detection after headspace sampling and gas chromatographic separation was evaluated for the detection of inhalants. Methanol, isopropanol, acetone, acetaldehyde, toluene, methyl ethyl ketone, isoamyl alcohol, isobutyl alcohol, n-butyl alcohol, 1,1-difluoroethane, 1,1,1-trifluoroethane, 1,1,1,2-tetrafluoroethane (Norflurane, HFC-134a), chloroethane, trichlorofluoromethane (Freon®-11), dichlorodifluoromethane (Freon®-12), dichlorofluoromethane (Freon®-21), chlorodifluoromethane (Freon®-22) and 1,2-dichlorotetrafluoroethane (Freon®-114) were validated for qualitative identification by this method. The validation for qualitative identification included evaluation of matrix effects, sensitivity, carryover, specificity, repeatability and ruggedness/robustness.

  10. Rapid and selective detection of acetone using hierarchical ZnO gas sensor for hazardous odor markers application

    International Nuclear Information System (INIS)

    Jia, Qianqian; Ji, Huiming; Zhang, Ying; Chen, Yalu; Sun, Xiaohong; Jin, Zhengguo

    2014-01-01

    Highlights: • ZnO spheres fabricated via solvothermal method are with (0 0 2) polar facet exposed. • Response time of ZnO sensor for detecting 100 ppm acetone is as short as 3 s. • R a /R g toward 100 ppm acetone is 33 when operated at 230 °C. • ZnO sensor exhibits good selectivity against other toxic gases and water vapor. • Porous structure and exposure of polar facet contribute to good sensing properties. - Abstract: Hierarchical nanostructured ZnO dandelion-like spheres were synthesized via solvothermal reaction at 200 °C for 4 h. The products were pure hexagonal ZnO with large exposure of (0 0 2) polar facet. Side-heating gas sensor based on hierarchical ZnO spheres was prepared to evaluate the acetone gas sensing properties. The detection limit to acetone for the ZnO sensor is 0.25 ppm. The response (R a /R g ) toward 100 ppm acetone was 33 operated at 230 °C and the response time was as short as 3 s. The sensor exhibited remarkable acetone selectivity with negligible response toward other hazardous gases and water vapor. The high proportion of electron depletion region and oxygen vacancies contributed to high gas response sensitivity. The hollow and porous structure of dandelion-like ZnO spheres facilitated the diffusion of gas molecules, leading to a rapid response speed. The largely exposed (0 0 2) polar facets could adsorb acetone gas molecules easily and efficiently, resulting in a rapid response speed and good selectivity of hierarchical ZnO spheres gas sensor at low operating temperature

  11. Impedance Method for Leak Detection in Zigzag Pipelines

    Science.gov (United States)

    Lay-Ekuakille, A.; Vergallo, P.; Trotta, A.

    2010-01-01

    Transportation of liquids is a primary aspect of human life. The most important infrastructure used accordingly is the pipeline. It serves as an asset for transporting different liquids and strategic goods. The latter are for example: chemical substances, oil, gas and water. Thus, it is necessary to monitor such infrastructures by means of specific tools. Leakage detection methods are used to reveal liquid leaks in pipelines for many applications, namely, waterworks, oil pipelines, industry heat exchangers, etc. The configuration of pipelines is a key issue because it impacts on the effectiveness of the method to be used and, consequently, on the results to be counterchecked. This research illustrated an improvement of the impedance method for zigzag pipeline by carrying out an experimental frequency analysis that has been compared with other methods based on frequency response. Hence, the impedance method is generally used for simple (straight) pipeline configurations because complicated pipelines with many curves introduce difficulties and major uncertainties in the calculation of characteristic impedance and in the statement of boundary conditions. The paper illustrates the case of a water pipeline where the leakage is acquired thanks to pressure transducers.

  12. A sensitive and efficient method for trace analysis of some phenolic compounds using simultaneous derivatization and air-assisted liquid-liquid microextraction from human urine and plasma samples followed by gas chromatography-nitrogen phosphorous detection.

    Science.gov (United States)

    Farajzadeh, Mir Ali; Afshar Mogaddam, Mohammad Reza; Alizadeh Nabil, Ali Akbar

    2015-12-01

    In present study, a simultaneous derivatization and air-assisted liquid-liquid microextraction method combined with gas chromatography-nitrogen phosphorous detection has been developed for the determination of some phenolic compounds in biological samples. The analytes are derivatized and extracted simultaneously by a fast reaction with 1-flouro-2,4-dinitrobenzene under mild conditions. Under optimal conditions low limits of detection in the range of 0.05-0.34 ng mL(-1) are achievable. The obtained extraction recoveries are between 84 and 97% and the relative standard deviations are less than 7.2% for intraday (n = 6) and interday (n = 4) precisions. The proposed method was demonstrated to be a simple and efficient method for the analysis of phenols in biological samples. Copyright © 2015 John Wiley & Sons, Ltd.

  13. ZnO:Al Thin Film Gas Sensor for Detection of Ethanol Vapor

    Directory of Open Access Journals (Sweden)

    Min Hsiung Hon

    2006-10-01

    Full Text Available The ZnO:Al thin films were prepared by RF magnetron sputtering on Si substrateusing Pt as interdigitated electrodes. The structure was characterized by XRD and SEManalyses, and the ethanol vapor gas sensing as well as electrical properties have beeninvestigated and discussed. The gas sensing results show that the sensitivity for detecting400 ppm ethanol vapor was ~20 at an operating temperature of 250°C. The high sensitivity,fast recovery, and reliability suggest that ZnO:Al thin film prepared by RF magnetronsputtering can be used for ethanol vapor gas sensing.

  14. A NEW METHOD OF PEAK DETECTION FOR ANALYSIS OF COMPREHENSIVE TWO-DIMENSIONAL GAS CHROMATOGRAPHY MASS SPECTROMETRY DATA.

    Science.gov (United States)

    Kim, Seongho; Ouyang, Ming; Jeong, Jaesik; Shen, Changyu; Zhang, Xiang

    2014-06-01

    We develop a novel peak detection algorithm for the analysis of comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GC×GC-TOF MS) data using normal-exponential-Bernoulli (NEB) and mixture probability models. The algorithm first performs baseline correction and denoising simultaneously using the NEB model, which also defines peak regions. Peaks are then picked using a mixture of probability distribution to deal with the co-eluting peaks. Peak merging is further carried out based on the mass spectral similarities among the peaks within the same peak group. The algorithm is evaluated using experimental data to study the effect of different cut-offs of the conditional Bayes factors and the effect of different mixture models including Poisson, truncated Gaussian, Gaussian, Gamma, and exponentially modified Gaussian (EMG) distributions, and the optimal version is introduced using a trial-and-error approach. We then compare the new algorithm with two existing algorithms in terms of compound identification. Data analysis shows that the developed algorithm can detect the peaks with lower false discovery rates than the existing algorithms, and a less complicated peak picking model is a promising alternative to the more complicated and widely used EMG mixture models.

  15. A NEW METHOD OF PEAK DETECTION FOR ANALYSIS OF COMPREHENSIVE TWO-DIMENSIONAL GAS CHROMATOGRAPHY MASS SPECTROMETRY DATA*

    Science.gov (United States)

    Kim, Seongho; Ouyang, Ming; Jeong, Jaesik; Shen, Changyu; Zhang, Xiang

    2014-01-01

    We develop a novel peak detection algorithm for the analysis of comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GC×GC-TOF MS) data using normal-exponential-Bernoulli (NEB) and mixture probability models. The algorithm first performs baseline correction and denoising simultaneously using the NEB model, which also defines peak regions. Peaks are then picked using a mixture of probability distribution to deal with the co-eluting peaks. Peak merging is further carried out based on the mass spectral similarities among the peaks within the same peak group. The algorithm is evaluated using experimental data to study the effect of different cut-offs of the conditional Bayes factors and the effect of different mixture models including Poisson, truncated Gaussian, Gaussian, Gamma, and exponentially modified Gaussian (EMG) distributions, and the optimal version is introduced using a trial-and-error approach. We then compare the new algorithm with two existing algorithms in terms of compound identification. Data analysis shows that the developed algorithm can detect the peaks with lower false discovery rates than the existing algorithms, and a less complicated peak picking model is a promising alternative to the more complicated and widely used EMG mixture models. PMID:25264474

  16. Fission gas detection system

    International Nuclear Information System (INIS)

    Colburn, R.P.

    1984-01-01

    A device for collecting fission gas released by failed fuel rods which device uses a filter adapted to pass coolant but to block passage of fission gas bubbles due to the surface tension of the bubbles. The coolant may be liquid metal. (author)

  17. Power-generation method using combined gas and steam turbines

    Energy Technology Data Exchange (ETDEWEB)

    Liu, C; Radtke, K; Keller, H J

    1997-03-20

    The invention concerns a method of power generation using a so-called COGAS (combined gas and steam) turbine installation, the aim being to improve the method with regard to the initial costs and energy consumption so that power can be generated as cheaply as possible. This is achieved by virtue of the fact that air taken from the surrounding atmosphere is splint into an essentially oxygen-containing stream and an essentially nitrogen-containing stream and the two streams fed further at approximately atmospheric pressure. The essentially nitrogen-containing stream is mixed with an air stream to form a mixed nitrogen/air stream and the mixed-gas stream thus produced is brought to combustion chamber pressure in the compressor of the gas turbine, the combustion of the combustion gases in the combustion chamber of the gas turbine being carried out with the greater part of this compressed mixed-gas stream. (author) figs.

  18. Technical Note: Detection of gas bubble leakage via correlation of water column multibeam images

    Science.gov (United States)

    Schneider von Deimling, J.; Papenberg, C.

    2012-03-01

    Hydroacoustic detection of natural gas release from the seafloor has been conducted in the past by using singlebeam echosounders. In contrast, modern multibeam swath mapping systems allow much wider coverage, higher resolution, and offer 3-D spatial correlation. Up to the present, the extremely high data rate hampers water column backscatter investigations and more sophisticated visualization and processing techniques are needed. Here, we present water column backscatter data acquired with a 50 kHz prototype multibeam system over a period of 75 seconds. Display types are of swath-images as well as of a "re-sorted" singlebeam presentation. Thus, individual and/or groups of gas bubbles rising from the 24 m deep seafloor clearly emerge in the acoustic images, making it possible to estimate rise velocities. A sophisticated processing scheme is introduced to identify those rising gas bubbles in the hydroacoustic data. We apply a cross-correlation technique adapted from particle imaging velocimetry (PIV) to the acoustic backscatter images. Temporal and spatial drift patterns of the bubbles are assessed and are shown to match very well to measured and theoretical rise patterns. The application of this processing to our field data gives clear results with respect to unambiguous bubble detection and remote bubble rise velocimetry. The method can identify and exclude the main source of misinterpretations, i.e. fish-mediated echoes. Although image-based cross-correlation techniques are well known in the field of fluid mechanics for high resolution and non-inversive current flow field analysis, we present the first application of this technique as an acoustic bubble detector.

  19. Technical Note: Detection of gas bubble leakage via correlation of water column multibeam images

    Directory of Open Access Journals (Sweden)

    J. Schneider von Deimling

    2012-03-01

    Full Text Available Hydroacoustic detection of natural gas release from the seafloor has been conducted in the past by using singlebeam echosounders. In contrast, modern multibeam swath mapping systems allow much wider coverage, higher resolution, and offer 3-D spatial correlation. Up to the present, the extremely high data rate hampers water column backscatter investigations and more sophisticated visualization and processing techniques are needed. Here, we present water column backscatter data acquired with a 50 kHz prototype multibeam system over a period of 75 seconds. Display types are of swath-images as well as of a "re-sorted" singlebeam presentation. Thus, individual and/or groups of gas bubbles rising from the 24 m deep seafloor clearly emerge in the acoustic images, making it possible to estimate rise velocities. A sophisticated processing scheme is introduced to identify those rising gas bubbles in the hydroacoustic data. We apply a cross-correlation technique adapted from particle imaging velocimetry (PIV to the acoustic backscatter images. Temporal and spatial drift patterns of the bubbles are assessed and are shown to match very well to measured and theoretical rise patterns. The application of this processing to our field data gives clear results with respect to unambiguous bubble detection and remote bubble rise velocimetry. The method can identify and exclude the main source of misinterpretations, i.e. fish-mediated echoes. Although image-based cross-correlation techniques are well known in the field of fluid mechanics for high resolution and non-inversive current flow field analysis, we present the first application of this technique as an acoustic bubble detector.

  20. Advances in methods for detection of anaerobic ammonium oxidizing (anammox) bacteria.

    Science.gov (United States)

    Li, Meng; Gu, Ji-Dong

    2011-05-01

    Anaerobic ammonium oxidation (anammox), the biochemical process oxidizing ammonium into dinitrogen gas using nitrite as an electron acceptor, has only been recognized for its significant role in the global nitrogen cycle not long ago, and its ubiquitous distribution in a wide range of environments has changed our knowledge about the contributors to the global nitrogen cycle. Currently, several groups of methods are used in detection of anammox bacteria based on their physiological and biochemical characteristics, cellular chemical composition, and both 16S rRNA gene and selective functional genes as biomarkers, including hydrazine oxidoreductase and nitrite reductase encoding genes hzo and nirS, respectively. Results from these methods coupling with advances in quantitative PCR, reverse transcription of mRNA genes and stable isotope labeling have improved our understanding on the distribution, diversity, and activity of anammox bacteria in different environments both natural and engineered ones. In this review, we summarize these methods used in detection of anammox bacteria from various environments, highlight the strengths and weakness of these methods, and also discuss the new development potentials on the existing and new techniques in the future.

  1. Preparation of Gas Sensor Based on Polymer Nanocomposite for Qualitative Detection of Hydrogen Sulfide

    Directory of Open Access Journals (Sweden)

    Elaheh Ghazizadeh

    2016-11-01

    Full Text Available Hydrogen sulfide (H2S, a by-product often produced in petrochemical processes, is well known as a dangerous and highly toxic gas to living organisms. The smell of H2S concentration of higher than 100 ppm can cause severe biological condition. Therefore, the detection of this gas is a crucial issue. In this work, nanocomposite porous films of polyurethane/silver (PU/Ag and poly(vinylchloride/silver (PVC/Ag consisting of 7 wt% nanoparticles were fabricated by phase inversion method and studied its qualitative detection capacity for H2S. The results indicated that after exposure to 50 ppm H2S, black points appeared on the surface of the test films within 10 min. However, the color completely disappeared when the films were left in the air for 20 min. Structural characteristics of the nanocomposites were studied by scanning electron microscopy (SEM, Fourier transform infrared spectroscopy (FTIR, X-ray diffractometry (XRD and thermal gravimetric analysis (TGA to confirm possible interactions which may have formed between the polymers and nanoparticles. According to the results, Ag nanoparticles were well dispersed in PU and PVC matrices giving particle sizes of less than 62 and 76 nm, respectively. The observations revealed that two recommended nanocomposites (PU/Ag and PVC/Ag could be used for detection of hydrogen sulfide at low level concentration. The response of Ag-embedded polymer films toward H2S vapour showed a better detection by PU/Ag compared to PVC/Ag. Therefore, the suggested silver nanoparticle-loaded PU and PVC sensor films are easily portable, simple to use and cost-less compared with other types of hydrogen sulfide sensors.

  2. A prediction method of natural gas hydrate formation in deepwater gas well and its application

    Directory of Open Access Journals (Sweden)

    Yanli Guo

    2016-09-01

    Full Text Available To prevent the deposition of natural gas hydrate in deepwater gas well, the hydrate formation area in wellbore must be predicted. Herein, by comparing four prediction methods of temperature in pipe with field data and comparing five prediction methods of hydrate formation with experiment data, a method based on OLGA & PVTsim for predicting the hydrate formation area in wellbore was proposed. Meanwhile, The hydrate formation under the conditions of steady production, throttling and shut-in was predicted by using this method based on a well data in the South China Sea. The results indicate that the hydrate formation area decreases with the increase of gas production, inhibitor concentrations and the thickness of insulation materials and increases with the increase of thermal conductivity of insulation materials and shutdown time. Throttling effect causes a plunge in temperature and pressure in wellbore, thus leading to an increase of hydrate formation area.

  3. Vibrational methods of the overhead gas-pipelines technological equipment diagnostics

    International Nuclear Information System (INIS)

    Zakhezin, A.M.; Malysheva, T.V.

    2001-01-01

    The diagnostic methods of overhead gas-pipelines of the technical equipment of gas-compressor station are considered in this article by carrying out registration certification documentation. Some faults of overhead technical gas-pipelines have been proposed. This paper is devoted to the diagnostic methods of the whole gas- pipelines and their parts for some faults during expert checking fulfillment and carrying out registration certification documentation. The analysis of all defects allows to determine a 'between-repairs interval', to develop some operations to avoid these faults and to estimate the repair operation quality, to reduce failure probability. As an example of the effectiveness of technical condition service of vibrational methods by expertise fulfillment have been considered for some defects of the overhead pipelines. (author)

  4. Estimation of the limit of detection in semiconductor gas sensors through linearized calibration models.

    Science.gov (United States)

    Burgués, Javier; Jiménez-Soto, Juan Manuel; Marco, Santiago

    2018-07-12

    The limit of detection (LOD) is a key figure of merit in chemical sensing. However, the estimation of this figure of merit is hindered by the non-linear calibration curve characteristic of semiconductor gas sensor technologies such as, metal oxide (MOX), gasFETs or thermoelectric sensors. Additionally, chemical sensors suffer from cross-sensitivities and temporal stability problems. The application of the International Union of Pure and Applied Chemistry (IUPAC) recommendations for univariate LOD estimation in non-linear semiconductor gas sensors is not straightforward due to the strong statistical requirements of the IUPAC methodology (linearity, homoscedasticity, normality). Here, we propose a methodological approach to LOD estimation through linearized calibration models. As an example, the methodology is applied to the detection of low concentrations of carbon monoxide using MOX gas sensors in a scenario where the main source of error is the presence of uncontrolled levels of humidity. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Adenovirus Detection by the cGAS/STING/TBK1 DNA Sensing Cascade

    Science.gov (United States)

    Lam, Eric; Stein, Saskia

    2014-01-01

    Adenovirus (Ad) infection triggers a cell-specific antiviral response following exposure of viral DNA to the intracellular compartment. A variety of DNA sensors (DAI, AIM2, DDx41, RNA polymerase [Pol] III, and IFI16 [p204]) have been identified in recent years; however, the DNA sensor involved in detection of adenovirus has not been established. Cyclic GMP-AMP synthase (cGAS), a DNA sensor that produces a cyclic guanine-adenine dinucleotide (cGAMP) inducer of STING, has been examined to determine its role in generating an antiadenoviral response. Short hairpin RNA (shRNA) lentiviral vectors targeting TBK1, STING, and cGAS were established in murine MS1 endothelial and RAW 264.7 macrophage cell lines. Knockdown of TBK1, STING, and cGAS results in a dramatic reduction in the activation of the primary antiviral response marker phosphorylated interferon (IFN) response factor 3 (IRF3) following exposure to adenovirus. Furthermore, activation of secondary type I IFN signaling targets (ptyrSTAT1 and ptyrSTAT2 [ptyrSTAT1/2]) was also compromised. Consistent with compromised activation of primary and secondary response markers, transcriptional activation of IRF3-responsive genes (beta IFN [IFN-β], ISG15, ISG54) and secondary response transcripts were diminished in cells knocked down in cGAS, STING, or TBK1. These data establish cGAS as the dominant cytosolic DNA sensor responsible for detection of internalized adenovirus leading to induction of the type I interferon antiviral cascade. PMID:24198409

  6. Stochastic Industrial Source Detection Using Lower Cost Methods

    Science.gov (United States)

    Thoma, E.; George, I. J.; Brantley, H.; Deshmukh, P.; Cansler, J.; Tang, W.

    2017-12-01

    Hazardous air pollutants (HAPs) can be emitted from a variety of sources in industrial facilities, energy production, and commercial operations. Stochastic industrial sources (SISs) represent a subcategory of emissions from fugitive leaks, variable area sources, malfunctioning processes, and improperly controlled operations. From the shared perspective of industries and communities, cost-effective detection of mitigable SIS emissions can yield benefits such as safer working environments, cost saving through reduced product loss, lower air shed pollutant impacts, and improved transparency and community relations. Methods for SIS detection can be categorized by their spatial regime of operation, ranging from component-level inspection to high-sensitivity kilometer scale surveys. Methods can be temporally intensive (providing snap-shot measures) or sustained in both time-integrated and continuous forms. Each method category has demonstrated utility, however, broad adoption (or routine use) has thus far been limited by cost and implementation viability. Described here are a subset of SIS methods explored by the U.S EPA's next generation emission measurement (NGEM) program that focus on lower cost methods and models. An emerging systems approach that combines multiple forms to help compensate for reduced performance factors of lower cost systems is discussed. A case study of a multi-day HAP emission event observed by a combination of low cost sensors, open-path spectroscopy, and passive samplers is detailed. Early field results of a novel field gas chromatograph coupled with a fast HAP concentration sensor is described. Progress toward near real-time inverse source triangulation assisted by pre-modeled facility profiles using the Los Alamos Quick Urban & Industrial Complex (QUIC) model is discussed.

  7. Method of detecting stacks with leaky fuel elements in liquid-metal-cooled reactor and apparatus for effecting same

    International Nuclear Information System (INIS)

    Aristarkhov, N.N.; Efimov, I.A.; Zaistev, B.I.; Peters, I.G.; Tymosh, B.S.

    1976-01-01

    Described is a method of detecting stacks with leaky fuel elements in a liquid-metal-cooled reactor, consisting in that prior to withdrawing a coolant sample, gas is accumulated in the coolant of the stack being controlled, the reactor being shut down, separated from the sample by means of an inert carrier gas, and the radioactivity of the separated gas is measured. An apparatus for carrying out said method comprises a sampler in the form of a tube parallel to the reactor axis in the hole of a rotating plug and adapted to move along the reactor axis. Made in the top portion of the tube are holes for the introduction of the inert carrier gas and the removal thereof together with the gases evolved from the coolant, while the bottom portion of the tube is provided with a sealing member

  8. Characterization of Reduced Graphene Oxide (rGO-Loaded SnO2 Nanocomposite and Applications in C2H2 Gas Detection

    Directory of Open Access Journals (Sweden)

    Lingfeng Jin

    2016-12-01

    Full Text Available Acetylene (C2H2 gas sensors were developed by synthesizing a reduced graphene oxide (rGO-loaded SnO2 hybrid nanocomposite via a facile two-step hydrothermal method. Morphological characterizations showed the formation of well-dispersed SnO2 nanoparticles loaded on the rGO sheets with excellent transparency and obvious fold boundary. Structural analysis revealed good agreement with the standard crystalline phases of SnO2 and rGO. Gas sensing characteristics of the synthesized materials were carried out in a temperature range of 100–300 °C with various concentrations of C2H2 gas. At 180 °C, the SnO2–rGO hybrid showed preferable detection of C2H2 with high sensor response (12.4 toward 50 ppm, fast response-recovery time (54 s and 23 s, limit of detection (LOD of 1.3 ppm and good linearity, with good selectivity and long-term stability. Furthermore, the possible gas sensing mechanism of the SnO2–rGO nanocomposites for C2H2 gas were summarized and discussed in detail. Our work indicates that the addition of rGO would be effective in enhancing the sensing properties of metal oxide-based gas sensors for C2H2 and may make a contribution to the development of an excellent ppm-level gas sensor for on-line monitoring of dissolved C2H2 gas in transformer oil.

  9. Doppler method leak detection for LMFBR steam generators. Pt. 3. Investigation of detection sensitivity and method

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi; Kinoshita, Izumi

    2001-01-01

    To prevent the expansion of tube damage and to maintain structural integrity in the steam generators (SGs) of a fast breeder reactor (FBR), it is necessary to detect precisely and immediately any leakage of water from heat transfer tubes. Therefore, the Doppler method was developed. Previous studies have revealed that, in the SG full-sector model that simulates actual SGs, the Doppler method can detect bubbles of 0.4 l/s within a few seconds. However in consideration of the dissolution rate of hydrogen generated by a sodium-water reaction even from a small water leak, it is necessary to detect smaller leakages of water from the heat transfer tubes. The detection sensitivity of the Doppler method and the influence of background noise were experimentally investigated. In-water experiments were performed using the SG model. The results show that the Doppler method can detect bubbles of 0.01 l/s (equivalent to a water leak rate of about 0.01 g/s) within a few seconds and that the background noise has little effect on water leak detection performance. The Doppler method thus has great potential for the detection of water leakage in SGs. (author)

  10. Bootstrap inversion technique for atmospheric trace gas source detection and quantification using long open-path laser measurements

    Directory of Open Access Journals (Sweden)

    C. B. Alden

    2018-03-01

    Full Text Available Advances in natural gas extraction technology have led to increased activity in the production and transport sectors in the United States and, as a consequence, an increased need for reliable monitoring of methane leaks to the atmosphere. We present a statistical methodology in combination with an observing system for the detection and attribution of fugitive emissions of methane from distributed potential source location landscapes such as natural gas production sites. We measure long (> 500 m, integrated open-path concentrations of atmospheric methane using a dual frequency comb spectrometer and combine measurements with an atmospheric transport model to infer leak locations and strengths using a novel statistical method, the non-zero minimum bootstrap (NZMB. The new statistical method allows us to determine whether the empirical distribution of possible source strengths for a given location excludes zero. Using this information, we identify leaking source locations (i.e., natural gas wells through rejection of the null hypothesis that the source is not leaking. The method is tested with a series of synthetic data inversions with varying measurement density and varying levels of model–data mismatch. It is also tested with field observations of (1 a non-leaking source location and (2 a source location where a controlled emission of 3.1  ×  10−5 kg s−1 of methane gas is released over a period of several hours. This series of synthetic data tests and outdoor field observations using a controlled methane release demonstrates the viability of the approach for the detection and sizing of very small leaks of methane across large distances (4+ km2 in synthetic tests. The field tests demonstrate the ability to attribute small atmospheric enhancements of 17 ppb to the emitting source location against a background of combined atmospheric (e.g., background methane variability and measurement uncertainty of 5 ppb (1σ, when

  11. A Small Leak Detection Method Based on VMD Adaptive De-Noising and Ambiguity Correlation Classification Intended for Natural Gas Pipelines.

    Science.gov (United States)

    Xiao, Qiyang; Li, Jian; Bai, Zhiliang; Sun, Jiedi; Zhou, Nan; Zeng, Zhoumo

    2016-12-13

    In this study, a small leak detection method based on variational mode decomposition (VMD) and ambiguity correlation classification (ACC) is proposed. The signals acquired from sensors were decomposed using the VMD, and numerous components were obtained. According to the probability density function (PDF), an adaptive de-noising algorithm based on VMD is proposed for noise component processing and de-noised components reconstruction. Furthermore, the ambiguity function image was employed for analysis of the reconstructed signals. Based on the correlation coefficient, ACC is proposed to detect the small leak of pipeline. The analysis of pipeline leakage signals, using 1 mm and 2 mm leaks, has shown that proposed detection method can detect a small leak accurately and effectively. Moreover, the experimental results have shown that the proposed method achieved better performances than support vector machine (SVM) and back propagation neural network (BP) methods.

  12. Calibration method based on direct radioactivity measurement for radioactive gas monitoring instruments

    International Nuclear Information System (INIS)

    Yoshida, Makoto; Ohi, Yoshihiro; Chida, Tohru; Wu, Youyang.

    1993-01-01

    A calibration method for radioactive gas monitoring instruments was studied. In the method, gaseous radioactivity standards were provided on the basis of the direct radioactivity measurement by the diffusion-in long proportional counter method (DLPC method). The radioactivity concentration of the gas mixture through a monitoring instrument was determined by sampling the known volume of the gas mixture into the proportional counter used for the DLPC method. Since oxygen in the gas mixture decreased the counting efficiency in a proportional counter, the influence on calibration was experimentally estimated. It was not serious and able to be easily corrected. By the present method, the relation between radioactivity concentration and ionization current was determined for a gas-flow ionization chamber with 1.5 l effective volume. It showed good agreement with the results in other works. (author)

  13. Design of improved detection instrumentation for the annulus gas system for wolsong 2

    International Nuclear Information System (INIS)

    Kim, Seog Nam; Koo, Jun Mo; Chang, Ik Ho; Jung, Ho Chang; Han, Sang Joon

    1996-01-01

    The improved and advanced Annulus Gas System (AGS) has been developed for Wolsong 2 to satisfy the requirements of the regulatory body. The Atomic Energy Control Board (AECB) required a shorter detection time following a small leak from a pressure tube and/or calandria tube. This paper describes licensing requirements, functional requirements and detail design description for the AGS. The Wolsong unit No. 1 AGS was designed to operate as a stagnant system normally requiring only pressure regulation and having provisions for purging. The improved AGS involves the adoption of gas recirculation in AGS, duplication of dew point indicators with additional instrumentation and sampling provisions to prompt operator action. The improved system operates in the recirculation mode with continuous dew point measurement for leak detection. An AGS with improved detection instrumentation is provided. 8 refs., 3 figs. (author)

  14. Determination of Low Concentrations of Acetochlor in Water by Automated Solid-Phase Extraction and Gas Chromatography with Mass-Selective Detection

    Science.gov (United States)

    Lindley, C.E.; Stewart, J.T.; Sandstrom, M.W.

    1996-01-01

    A sensitive and reliable gas chromatographic/mass spectrometric (GC/MS) method for determining acetochlor in environmental water samples was developed. The method involves automated extraction of the herbicide from a filtered 1 L water sample through a C18 solid-phase extraction column, elution from the column with hexane-isopropyl alcohol (3 + 1), and concentration of the extract with nitrogen gas. The herbicide is quantitated by capillary/column GC/MS with selected-ion monitoring of 3 characteristic ions. The single-operator method detection limit for reagent water samples is 0.0015 ??g/L. Mean recoveries ranged from about 92 to 115% for 3 water matrixes fortified at 0.05 and 0.5 ??g/L. Average single-operator precision, over the course of 1 week, was better than 5%.

  15. DETECTION OF MOLECULAR GAS IN VOID GALAXIES: IMPLICATIONS FOR STAR FORMATION IN ISOLATED ENVIRONMENTS

    Energy Technology Data Exchange (ETDEWEB)

    Das, M.; Honey, M. [Indian Institute of Astrophysics, Bangalore (India); Saito, T. [Department of Astronomy, Graduate school of Science, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 133-0033 (Japan); Iono, D. [Chile Observatory, NAOJ (Japan); Ramya, S., E-mail: mousumi@iiap.res.in [Shanghai Astronomical Observatory, Shanghai (China)

    2015-12-10

    We present the detection of molecular gas from galaxies located in nearby voids using the CO(1–0) line emission as a tracer. The observations were performed using the 45 m single dish radio telescope of the Nobeyama Radio Observatory. Void galaxies lie in the most underdense parts of our universe and a significant fraction of them are gas rich, late-type spiral galaxies. Although isolated, they have ongoing star formation but appear to be slowly evolving compared to galaxies in denser environments. Not much is known about their star formation properties or cold gas content. In this study, we searched for molecular gas in five void galaxies. The galaxies were selected based on their relatively high IRAS fluxes or Hα line luminosities, both of which signify ongoing star formation. All five galaxies appear to be isolated and two lie within the Bootes void. We detected CO(1–0) emission from four of the five galaxies in our sample and their molecular gas masses lie between 10{sup 8} and 10{sup 9} M{sub ⊙}. We conducted follow-up Hα imaging observations of three detected galaxies using the Himalayan Chandra Telescope and determined their star formation rates (SFRs) from their Hα fluxes. The SFR varies from 0.2 to 1 M{sub ⊙} yr{sup −1}; which is similar to that observed in local galaxies. Our study indicates that although void galaxies reside in underdense regions, their disks contain molecular gas and have SFRs similar to galaxies in denser environments. We discuss the implications of our results.

  16. Derivatizations for improved detection of alcohols by gas chromatography and photoionization detection (GC-PID)

    International Nuclear Information System (INIS)

    Krull, I.S.; Swartz, M.; Driscoll, J.N.

    1984-01-01

    Pentafluorophenyldimethylsilyl chloride (flophemesyl chloride, Fl) is a well known derivatization reagent for improved electron capture detection (ECD) in gas chromatography (GC)(GC-ECD), but it has never been utilized for improved detectability and sensitivity in GC-photoionization detection (GC-PID). A wide variety of flophemesyl alcohol derivatives have been used in order to show a new approach for realizing greatly reduced minimum detection limits (MDL) of virtually all alcohol derivatives in GC-PID analysis. This particular derivatization approach is inexpensive and easy to apply, leading to quantitative or near 100% conversion of the starting alcohols to the expected flophemesyl ethers (silyl ethers). Detection limits can be lowered by 2-3 orders of magnitude for such derivatives when compared with the starting alcohols, along with calibration plots that are linear over 5-7 orders of magnitude. Specific GC conditions have been developed for many flophemesyl derivatives, in all cases using packed columns. Both ECD and PID relative response factors (RRFs) and normalized RRFs have been determined, and such ratios can now be used for improved analytic identification from complex sample matrices, where appropriate. 28 references, 2 figures, 5 tables

  17. Method to detect steam generator tube leakage

    International Nuclear Information System (INIS)

    Watabe, Kiyomi

    1994-01-01

    It is important for plant operation to detect minor leakages from the steam generator tube at an early stage, thus, leakage detection has been performed using a condenser air ejector gas monitor and a steam generator blow down monitor, etc. In this study highly-sensitive main steam line monitors have been developed in order to identify leakages in the steam generator more quickly and accurately. The performance of the monitors was verified and the demonstration test at the actual plant was conducted for their intended application to the plants. (author)

  18. Carbon Nanotube-Silicon Nanowire Heterojunction Solar Cells with Gas-Dependent Photovoltaic Performances and Their Application in Self-Powered NO2 Detecting.

    Science.gov (United States)

    Jia, Yi; Zhang, Zexia; Xiao, Lin; Lv, Ruitao

    2016-12-01

    A multifunctional device combining photovoltaic conversion and toxic gas sensitivity is reported. In this device, carbon nanotube (CNT) membranes are used to cover onto silicon nanowire (SiNW) arrays to form heterojunction. The porous structure and large specific surface area in the heterojunction structure are both benefits for gas adsorption. In virtue of these merits, gas doping is a feasible method to improve cell's performance and the device can also work as a self-powered gas sensor beyond a solar cell. It shows a significant improvement in cell efficiency (more than 200 times) after NO2 molecules doping (device working as a solar cell) and a fast, reversible response property for NO2 detection (device working as a gas sensor). Such multifunctional CNT-SiNW structure can be expected to open a new avenue for developing self-powered, efficient toxic gas-sensing devices in the future.

  19. A Small Leak Detection Method Based on VMD Adaptive De-Noising and Ambiguity Correlation Classification Intended for Natural Gas Pipelines

    Directory of Open Access Journals (Sweden)

    Qiyang Xiao

    2016-12-01

    Full Text Available In this study, a small leak detection method based on variational mode decomposition (VMD and ambiguity correlation classification (ACC is proposed. The signals acquired from sensors were decomposed using the VMD, and numerous components were obtained. According to the probability density function (PDF, an adaptive de-noising algorithm based on VMD is proposed for noise component processing and de-noised components reconstruction. Furthermore, the ambiguity function image was employed for analysis of the reconstructed signals. Based on the correlation coefficient, ACC is proposed to detect the small leak of pipeline. The analysis of pipeline leakage signals, using 1 mm and 2 mm leaks, has shown that proposed detection method can detect a small leak accurately and effectively. Moreover, the experimental results have shown that the proposed method achieved better performances than support vector machine (SVM and back propagation neural network (BP methods.

  20. Design, Evaluation and Implementation of an Islanding Detection Method for a Micro-grid

    Directory of Open Access Journals (Sweden)

    Taiying Zheng

    2018-02-01

    Full Text Available Correct and fast detection of a micro-grid (MG islanding is essential to the MG since operation, control, and protection of the MG depend on its operating mode i.e., an interconnected mode or islanding mode. This study describes the design, evaluation and implementation of an islanding detection method for an MG, which includes a natural gas-fired generator, a doubly fed induction generator type wind generator, a photovoltaic generator, and some associated local loads. The proposed method is based on the instantaneous active and reactive powers at the point of common coupling (PCC of the MG. During the islanding mode, the instantaneous active and reactive powers at the PCC are constants, which depend on the voltage of the PCC and the impedance of the dedicated line. The performance of the proposed method is verified under various scenarios including islanding conditions for the different outputs of the MG, and fault conditions by varying the position, type, inception angle and resistance of the fault, using the PSCAD/EMTDC simulator. This paper also concludes by implementing proposed method into a TMS320C6701 digital signal processor. The results indicate that the proposed method successfully detects islanding for the MG in islanding conditions, and remains stable in fault conditions.

  1. Room-Temperature H2 Gas Sensing Characterization of Graphene-Doped Porous Silicon via a Facile Solution Dropping Method

    Directory of Open Access Journals (Sweden)

    Nu Si A. Eom

    2017-11-01

    Full Text Available In this study, a graphene-doped porous silicon (G-doped/p-Si substrate for low ppm H2 gas detection by an inexpensive synthesis route was proposed as a potential noble graphene-based gas sensor material, and to understand the sensing mechanism. The G-doped/p-Si gas sensor was synthesized by a simple capillary force-assisted solution dropping method on p-Si substrates, whose porosity was generated through an electrochemical etching process. G-doped/p-Si was fabricated with various graphene concentrations and exploited as a H2 sensor that was operated at room temperature. The sensing mechanism of the sensor with/without graphene decoration on p-Si was proposed to elucidate the synergetic gas sensing effect that is generated from the interface between the graphene and p-type silicon.

  2. Electrical Versus Optical: Comparing Methods for Detecting Terahertz Radiation Using Neon Lamps

    Science.gov (United States)

    Slocombe, L. L.; Lewis, R. A.

    2018-05-01

    Terahertz radiation impinging on a lit neon tube causes additional ionization of the encapsulated gas. As a result, the electrical current flowing between the electrodes increases and the glow discharge in the tube brightens. These dual phenomena suggest two distinct modes of terahertz sensing. The electrical mode simply involves measuring the electrical current. The optical mode involves monitoring the brightness of the weakly ionized plasma glow discharge. Here, we directly compare the two detection modes under identical experimental conditions. We measure 0.1-THz radiation modulated at frequencies in the range 0.1-10 kHz, for lamp currents in the range 1-10 mA. We find that electrical detection provides a superior signal-to-noise ratio while optical detection has a faster response. Either method serves as the basis of a compact, robust, and inexpensive room-temperature detector of terahertz radiation.

  3. Controlled synthesis of ZnO hollow microspheres via precursor-template method and its gas sensing property

    International Nuclear Information System (INIS)

    Tian, Yu; Li, Jinchai; Xiong, Hui; Dai, Jiangnan

    2012-01-01

    Highlights: ► Zn powder as precursor template for synthesis ZnO hollow spheres. ► Different precursor templates result in different ZnO nanostructures. ► Different experimental conditions enable growth of different surface morphologies of ZnO sphere. ► ZnO hollow sphere materials have good gas sensing performance for detecting ethanol gas. - Abstract: Using Zn powder as precursor templates, ZnO hollow microspheres were successfully prepared by thermal evaporation method and characterized by X-ray diffraction analysis, scanning electron microscope and transmission electron microscope. It was found that different size and shape of precursor resulted in different ZnO nanostructures. When varying experimental conditions, such as air flow rate and working pressure, ZnO hollow spheres with different surface morphologies could be obtained. The advantages of the present synthetic technology are simple, relatively low cost, and high reproducibility. A gas sensor was fabricated from the as-prepared ZnO hollow microspheres and tested to the ethanol gas at different operating temperatures.

  4. Methods of Off-Gas Flammability Control for DWPF Melter Off-Gas System at Savannah River Site

    International Nuclear Information System (INIS)

    Choi, A.S.; Iverson, D.C.

    1996-01-01

    Several key operating variables affecting off-gas flammability in a slurry-fed radioactive waste glass melter are discussed, and the methods used to prevent potential off-gas flammability are presented. Two models have played a central role in developing such methods. The first model attempts to describe the chemical events occurring during the calcining and melting steps using a multistage thermodynamic equilibrium approach, and it calculates the compositions of glass and calcine gases. Volatile feed components and calcine gases are fed to the second model which then predicts the process dynamics of the entire melter off-gas system including off-gas flammability under both steady state and various transient operating conditions. Results of recent simulation runs are also compared with available data

  5. Method of storing radioactive rare gas. [gas occupies spaces in the zeolite crystal lattice

    Energy Technology Data Exchange (ETDEWEB)

    Nagao, H; Miharada, H; Takiguchi, Y; Kanazawa, T; Soya, M

    1975-05-15

    A method is provided to prevent dispersion of radioactive rare gas atoms by sealing them in a pressurised state within zeolite and thereby confining them in position within the zeolite crystal lattice. Radioactive rare gas is separated from exhaust gas and concentrated by using a low temperature adsorption means or liquefaction distillation means and necessary accessory means, and then it is temporarily stored in a gas holder. When a predetermined quantity of storage is reached, the gas is led to a sealing tank containing zeolite heated to 300 to 400/sup 0/C and held at 3,000 to 4,000 atmospheres, and under this condition radioactive rare gas is brought to occupy the spaces in the zeolite crystal lattice. After equilibrium pressure is reached by the pressure in the tank at that temperature, the gas is cooled in the pressurised state down to room temperature. Subsequently, the rare gas remaining in the tank and duct is recovered by a withdrawal pump into the gas holder. Thereafter, the zeolite with radioactive rare gas sealed in it is taken out from the tank and sealed within a long period storage container, which is then housed in a predetermined place for storage.

  6. Method for treating a nuclear process off-gas stream

    International Nuclear Information System (INIS)

    Pence, D.T.; Chou, C.C.

    1984-01-01

    Disclosed is a method for selectively removing and recovering the noble gas and other gaseous components typically emitted during nuclear process operations. The method is adaptable and useful for treating dissolver off-gas effluents released during reprocessing of spent nuclear fuels whereby to permit radioactive contaminant recovery prior to releasing the remaining off-gases to the atmosphere. Briefly, the method sequentially comprises treating the off-gas stream to preliminarily remove NO /SUB x/ , hydrogen and carbon-containing organic compounds, and semivolatile fission product metal oxide components therefrom; adsorbing iodine components on silver-exchanged mordenite; removing water vapor carried by said stream by means of a molecular sieve; selectively removing the carbon dioxide components of said off-gas stream by means of a molecular sieve; selectively removing xenon in gas phase by passing said stream through a molecular sieve comprising silver-exchanged mordenite; selectively separating krypton from oxygen by means of a molecular sieve comprising silver-exchanged mordenite; selectively separating krypton from the bulk nitrogen stream using a molecular sieve comprising silver-exchanged mordenite cooled to about -140 0 to -160 0 C.; concentrating the desorbed krypton upon a molecular sieve comprising silver-exchange mordenite cooled to about -140 0 to -160 0 C.; and further cryogenically concentrating, and the recovering for storage, the desorbed krypton

  7. Method for treating a nuclear process off-gas stream

    Science.gov (United States)

    Pence, Dallas T.; Chou, Chun-Chao

    1984-01-01

    Disclosed is a method for selectively removing and recovering the noble gas and other gaseous components typically emitted during nuclear process operations. The method is adaptable and useful for treating dissolver off-gas effluents released during reprocessing of spent nuclear fuels whereby to permit radioactive contaminant recovery prior to releasing the remaining off-gases to the atmosphere. Briefly, the method sequentially comprises treating the off-gas stream to preliminarily remove NO.sub.x, hydrogen and carbon-containing organic compounds, and semivolatile fission product metal oxide components therefrom; adsorbing iodine components on silver-exchanged mordenite; removing water vapor carried by said stream by means of a molecular sieve; selectively removing the carbon dioxide components of said off-gas stream by means of a molecular sieve; selectively removing xenon in gas phase by passing said stream through a molecular sieve comprising silver-exchanged mordenite; selectively separating krypton from oxygen by means of a molecular sieve comprising silver-exchanged mordenite; selectively separating krypton from the bulk nitrogen stream using a molecular sieve comprising silver-exchanged mordenite cooled to about -140.degree. to -160.degree. C.; concentrating the desorbed krypton upon a molecular sieve comprising silver-exchange mordenite cooled to about -140.degree. to -160.degree. C.; and further cryogenically concentrating, and the recovering for storage, the desorbed krypton.

  8. Characteristic Value Method of Well Test Analysis for Horizontal Gas Well

    Directory of Open Access Journals (Sweden)

    Xiao-Ping Li

    2014-01-01

    Full Text Available This paper presents a study of characteristic value method of well test analysis for horizontal gas well. Owing to the complicated seepage flow mechanism in horizontal gas well and the difficulty in the analysis of transient pressure test data, this paper establishes the mathematical models of well test analysis for horizontal gas well with different inner and outer boundary conditions. On the basis of obtaining the solutions of the mathematical models, several type curves are plotted with Stehfest inversion algorithm. For gas reservoir with closed outer boundary in vertical direction and infinite outer boundary in horizontal direction, while considering the effect of wellbore storage and skin effect, the pseudopressure behavior of the horizontal gas well can manifest four characteristic periods: pure wellbore storage period, early vertical radial flow period, early linear flow period, and late horizontal pseudoradial flow period. For gas reservoir with closed outer boundary both in vertical and horizontal directions, the pseudopressure behavior of the horizontal gas well adds the pseudosteady state flow period which appears after the boundary response. For gas reservoir with closed outer boundary in vertical direction and constant pressure outer boundary in horizontal direction, the pseudopressure behavior of the horizontal gas well adds the steady state flow period which appears after the boundary response. According to the characteristic lines which are manifested by pseudopressure derivative curve of each flow period, formulas are developed to obtain horizontal permeability, vertical permeability, skin factor, reservoir pressure, and pore volume of the gas reservoir, and thus the characteristic value method of well test analysis for horizontal gas well is established. Finally, the example study verifies that the new method is reliable. Characteristic value method of well test analysis for horizontal gas well makes the well test analysis

  9. Gas chromatographic determination of impurities of inorganic compounds

    International Nuclear Information System (INIS)

    Drugov, Yu.S.

    1985-01-01

    Methods of concentration, separation, detection in gas chromatographic determination of impurities of inorganic compounds including low-boiling gases, reactive gases, organometallic compounds, free metals, anions, etc. are reviewed. Methods of reaction gas chromatography for determining reactive gases, water, anions, metal chelates are considered in detail as well as methods of reaction-sorption concentration and reaction gas extraction. The application of gas chromatograpny ior anaiysis of water and atmosphere contamination, for determination of impurities in highly pure solid substances and gases is described

  10. Comparison of Methods for Oscillation Detection

    DEFF Research Database (Denmark)

    Odgaard, Peter Fogh; Trangbæk, Klaus

    2006-01-01

    This paper compares a selection of methods for detecting oscillations in control loops. The methods are tested on measurement data from a coal-fired power plant, where some oscillations are occurring. Emphasis is put on being able to detect oscillations without having a system model and without...... using process knowledge. The tested methods show potential for detecting the oscillations, however, transient components in the signals cause false detections as well, motivating usage of models in order to remove the expected signals behavior....

  11. A Voltage Quality Detection Method

    DEFF Research Database (Denmark)

    Chen, Zhe; Wei, Mu

    2008-01-01

    This paper presents a voltage quality detection method based on a phase-locked loop (PLL) technique. The technique can detect the voltage magnitude and phase angle of each individual phase under both normal and fault power system conditions. The proposed method has the potential to evaluate various...

  12. A fast complex domain-matching pursuit algorithm and its application to deep-water gas reservoir detection

    Science.gov (United States)

    Zeng, Jing; Huang, Handong; Li, Huijie; Miao, Yuxin; Wen, Junxiang; Zhou, Fei

    2017-12-01

    The main emphasis of exploration and development is shifting from simple structural reservoirs to complex reservoirs, which all have the characteristics of complex structure, thin reservoir thickness and large buried depth. Faced with these complex geological features, hydrocarbon detection technology is a direct indication of changes in hydrocarbon reservoirs and a good approach for delimiting the distribution of underground reservoirs. It is common to utilize the time-frequency (TF) features of seismic data in detecting hydrocarbon reservoirs. Therefore, we research the complex domain-matching pursuit (CDMP) method and propose some improvements. First is the introduction of a scale parameter, which corrects the defect that atomic waveforms only change with the frequency parameter. Its introduction not only decomposes seismic signal with high accuracy and high efficiency but also reduces iterations. We also integrate jumping search with ergodic search to improve computational efficiency while maintaining the reasonable accuracy. Then we combine the improved CDMP with the Wigner-Ville distribution to obtain a high-resolution TF spectrum. A one-dimensional modeling experiment has proved the validity of our method. Basing on the low-frequency domain reflection coefficient in fluid-saturated porous media, we finally get an approximation formula for the mobility attributes of reservoir fluid. This approximation formula is used as a hydrocarbon identification factor to predict deep-water gas-bearing sand of the M oil field in the South China Sea. The results are consistent with the actual well test results and our method can help inform the future exploration of deep-water gas reservoirs.

  13. Development and evaluation of a gas chromatographic method for the determination of triazine herbicides in natural water samples

    Science.gov (United States)

    Steinheimer, T.R.; Brooks, M.G.

    1984-01-01

    A multi-residue method is described for the determination of triazine herbicides in natural water samples. The technique uses solvent extraction followed by gas chromatographic separation and detection employing nitrogen-selective devices. Seven compounds can be determined simultaneously at a nominal detection limit of 0.1 ??g/L in a 1-litre sample. Three different natural water samples were used for error analysis via evaluation of recovery efficiencies and estimation of overall method precision. As an alternative to liquid-liquid partition (solvent extraction) for removal of compounds of interest from water, solid-phase extraction (SPE) techniques employing chromatographic grade silicas with chemically modified surfaces have been examined. SPE is found to provide rapid and efficient concentration with quantitative recovery of some triazine herbicides from natural water samples. Concentration factors of 500 to 1000 times are obtained readily by the SPE technique.A multi-residue method is described for the determination of triazine herbicides in natural water samples. The technique uses solvent extraction followed by gas chromatographic separation and detection employing nitrogen-selective devices. Seven compounds can be determined simultaneously at a nominal detection limit of 0. 1 mu g/L in a 1-litre sample. As an alternative to liquid-liquid partition (solvent extraction) for removal of compounds of interest from water, solid-phase extraction (SPE) techniques employing chromatographic grade silicas with chemically modified surfaces have been examined. SPE is found to provide rapid and efficient concentration with quantitative recovery of some triazine herbicides from natural water samples. Concentration factors of 500 to 1000 times are obtained readily by the SPE technique.

  14. Role of the Material Electrodes on Resistive Behaviour of Carbon Nanotube-Based Gas Sensors for H2S Detection

    Directory of Open Access Journals (Sweden)

    M. Lucci

    2012-01-01

    Full Text Available Miniaturized gas-sensing devices that use single-walled carbon nanotubes as active material have been fabricated using two different electrode materials, namely, Au/Cr and NbN. The resistive sensors have been assembled aligning by dielectrophoresis the nanotube bundles between 40 μm spaced Au/Cr or NbN multifinger electrodes. The sensing devices have been tested for detection of the H2S gas, in the concentration range 10–100 ppm, using N2 as carrier gas. No resistance changes were detected using sensor fabricated with NbN electrodes, whereas the response of the sensor fabricated with Au/Cr electrodes was characterized by an increase of the resistance upon gas exposure. The main performances of this sensor are a detection limit for H2S of 10 ppm and a recovery time of few minutes. The present study suggests that the mechanism involved in H2S gas detection is not a direct charge transfer between molecules and nanotubes. The hypothesis is that detection occurs through passivation of the Au surfaces by H2S molecules and modification of the contact resistance at the Au/nanotube interface.

  15. Leak detection by vibrational diagnostic methods

    International Nuclear Information System (INIS)

    Siklossy, P.

    1983-01-01

    The possibilities and methods of leak detection due to mechanical failures in nuclear power plants are reviewed on the basis of the literature. Great importance is attributed to vibrational diagnostic methods for their adventageous characteristics which enable them to become final leak detecting methods. The problems of noise analysis, e.g. leak detection by impact sound measurements, probe characteristics, gain problems, probe selection, off-line analysis and correlation functions, types of leak noises etc. are summarized. Leak detection based on noise analysis can be installed additionally to power plants. Its maintenance and testing is simple. On the other hand, it requires special training and measuring methods. (Sz.J.)

  16. Method of optimization of the natural gas refining process

    Energy Technology Data Exchange (ETDEWEB)

    Sadykh-Zade, E.S.; Bagirov, A.A.; Mardakhayev, I.M.; Razamat, M.S.; Tagiyev, V.G.

    1980-01-01

    The SATUM (automatic control system of technical operations) system introduced at the Shatlyk field should assure good quality of gas refining. In order to optimize the natural gas refining processes and experimental-analytical method is used in compiling the mathematical descriptions. The program, compiled in Fortran language, in addition to parameters of optimal conditions gives information on the yield of concentrate and water, concentration and consumption of DEG, composition and characteristics of the gas and condensate. The algorithm for calculating optimum engineering conditions of gas refining is proposed to be used in ''advice'' mode, and also for monitoring progress of the gas refining process.

  17. Method of making an aero-derivative gas turbine engine

    Science.gov (United States)

    Wiebe, David J.

    2018-02-06

    A method of making an aero-derivative gas turbine engine (100) is provided. A combustor outer casing (68) is removed from an existing aero gas turbine engine (60). An annular combustor (84) is removed from the existing aero gas turbine engine. A first row of turbine vanes (38) is removed from the existing aero gas turbine engine. A can annular combustor assembly (122) is installed within the existing aero gas turbine engine. The can annular combustor assembly is configured to accelerate and orient combustion gasses directly onto a first row of turbine blades of the existing aero gas turbine engine. A can annular combustor assembly outer casing (108) is installed to produce the aero-derivative gas turbine engine (100). The can annular combustor assembly is installed within an axial span (85) of the existing aero gas turbine engine vacated by the annular combustor and the first row of turbine vanes.

  18. Determination of methyl mercury by aqueous phase Eehylation, followed by gas chromatographic separation with cold vapor atomic fluorescence detection

    Science.gov (United States)

    De Wild, John F.; Olsen, Mark L.; Olund, Shane D.

    2002-01-01

    A recent national sampling of streams in the United States revealed low methyl mercury concentrations in surface waters. The resulting median and mean concentrations, calculated from 104 samples, were 0.06 nanograms per liter (ng/L) and 0.15 ng/L, respectively. This level of methyl mercury in surface water in the United States has created a need for analytical techniques capable of detecting sub-nanogram per liter concentrations. In an attempt to create a U.S. Geological Survey approved method, the Wisconsin District Mercury Laboratory has adapted a distillation/ethylation/ gas-phase separation method with cold vapor atomic fluorescence spectroscopy detection for the determination of methyl mercury in filtered and unfiltered waters. This method is described in this report. Based on multiple analyses of surface water and ground-water samples, a method detection limit of 0.04 ng/L was established. Precision and accuracy were evaluated for the method using both spiked and unspiked ground-water and surface-water samples. The percent relative standard deviations ranged from 10.2 to 15.6 for all analyses at all concentrations. Average recoveries obtained for the spiked matrices ranged from 88.8 to 117 percent. The precision and accuracy ranges are within the acceptable method-performance limits. Considering the demonstrated detection limit, precision, and accuracy, the method is an effective means to quantify methyl mercury in waters at or below environmentally relevant concentrations

  19. AIRBORNE, OPTICAL REMOTE SENSNG OF METHANE AND ETHANE FOR NATURAL GAS PIPELINE LEAK DETECTION

    Energy Technology Data Exchange (ETDEWEB)

    Jerry Myers

    2005-04-15

    Ophir Corporation was awarded a contract by the U. S. Department of Energy, National Energy Technology Laboratory under the Project Title ''Airborne, Optical Remote Sensing of Methane and Ethane for Natural Gas Pipeline Leak Detection'' on October 14, 2002. The scope of the work involved designing and developing an airborne, optical remote sensor capable of sensing methane and, if possible, ethane for the detection of natural gas pipeline leaks. Flight testing using a custom dual wavelength, high power fiber amplifier was initiated in February 2005. Ophir successfully demonstrated the airborne system, showing that it was capable of discerning small amounts of methane from a simulated pipeline leak. Leak rates as low as 150 standard cubic feet per hour (scf/h) were detected by the airborne sensor.

  20. Method of detecting leakage from geologic formations used to sequester CO.sub.2

    Science.gov (United States)

    White, Curt [Pittsburgh, PA; Wells, Arthur [Bridgeville, PA; Diehl, J Rodney [Pittsburgh, PA; Strazisar, Brian [Venetia, PA

    2010-04-27

    The invention provides methods for the measurement of carbon dioxide leakage from sequestration reservoirs. Tracer moieties are injected along with carbon dioxide into geological formations. Leakage is monitored by gas chromatographic analyses of absorbents. The invention also provides a process for the early leak detection of possible carbon dioxide leakage from sequestration reservoirs by measuring methane (CH.sub.4), ethane (C.sub.2H.sub.6), propane (C.sub.3H.sub.8), and/or radon (Rn) leakage rates from the reservoirs. The invention further provides a method for branding sequestered carbon dioxide using perfluorcarbon tracers (PFTs) to show ownership.

  1. The Huber’s Method-based Gas Concentration Reconstruction in Multicomponent Gas Mixtures from Multispectral Laser Measurements under Noise Overshoot Conditions

    Directory of Open Access Journals (Sweden)

    V. A. Gorodnichev

    2016-01-01

    Full Text Available Laser gas analysers are the most promising for the rapid quantitative analysis of gaseous air pollution. A laser gas analysis problem is that there are instable results in reconstruction of gas mixture components concentration under real noise in the recorded laser signal. This necessitates using the special processing algorithms. When reconstructing the quantitative composition of multi-component gas mixtures from the multispectral laser measurements are efficiently used methods such as Tikhonov regularization, quasi-solution search, and finding of Bayesian estimators. These methods enable using the single measurement results to determine the quantitative composition of gas mixtures under measurement noise. In remote sensing the stationary gas formations or in laboratory analysis of the previously selected (when the gas mixture is stationary air samples the reconstruction procedures under measurement noise of gas concentrations in multicomponent mixtures can be much simpler. The paper considers a problem of multispectral laser analysis of stationary gas mixtures for which it is possible to conduct a series of measurements. With noise overshoots in the recorded laser signal (and, consequently, overshoots of gas concentrations determined by a single measurement must be used stable (robust estimation techniques for substantial reducing an impact of the overshoots on the estimate of required parameters. The paper proposes the Huber method to determine gas concentrations in multicomponent mixtures under signal overshoot. To estimate the value of Huber parameter and the efficiency of Huber's method to find the stable estimates of gas concentrations in multicomponent stationary mixtures from the laser measurements the mathematical modelling was conducted. Science & Education of the Bauman MSTU 108 The mathematical modelling results show that despite the considerable difference among the errors of the mixture gas components themselves a character of

  2. Simultaneous detection of xenon and krypton in equine plasma by gas chromatography-tandem mass spectrometry for doping control.

    Science.gov (United States)

    Kwok, Wai Him; Choi, Timmy L S; So, Pui-Kin; Yao, Zhong-Ping; Wan, Terence S M

    2017-02-01

    Xenon can activate the hypoxia-inducible factors (HIFs). As such, it has been allegedly used in human sports for increasing erythropoiesis. Krypton, another noble gas with reported narcosis effect, can also be expected to be a potential and less expensive erythropoiesis stimulating agent. This has raised concern about the misuse of noble gases as doping agents in equine sports. The aim of the present study is to establish a method for the simultaneous detection of xenon and krypton in equine plasma for the purpose of doping control. Xenon- or krypton-fortified equine plasma samples were prepared according to reported protocols. The target noble gases were simultaneously detected by gas chromatography-triple quadrupole mass spectrometry using headspace injection. Three xenon isotopes at m/z 129, 131, and 132, and four krypton isotopes at m/z 82, 83, 84, and 86 were targeted in selected reaction monitoring mode (with the precursor ions and product ions at identical mass settings), allowing unambiguous identification of the target analytes. Limits of detection for xenon and krypton were about 19 pmol/mL and 98 pmol/mL, respectively. Precision for both analytes was less than 15%. The method has good specificity as background analyte signals were not observed in negative equine plasma samples (n = 73). Loss of analytes under different storage temperatures has also been evaluated. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  3. Gas chromatographic sensing on an optical fiber by mode-filtered light detection.

    Science.gov (United States)

    Bruckner, C A; Synovec, R E

    1996-06-01

    A chemical sensor for gas phase measurements is reported which combines the principles of chemical separation and fiber optic detection. The analyzer incorporates an annular column Chromatographic sensor, constructed by inserting a polymer-clad optical fiber into a silica capillary. Light from a helium-neon laser is launched down the fiber, producing a steady intensity distribution within the fiber, but a low background of scattered light. When sample vapor is introduced to the sensor, and an analyte-rich volume interacts with the polymer cladding, Chromatographic retention is observed simultaneously with a change in the local refractive index of the cladding. An increase in cladding refractive index (RI) causes light to be coupled out of the fiber, with detection at a right-angle to the annular column length to provide optimum S/N ratio. This detection mechanism is called mode-filtered light detection. We report a gas Chromatographic separation on a 3.1 m annular column (320 microm i.d. silica tube, 228 microm o.d. fiber with a 12 microm fluorinated silicone clad) of methane, benzene, butanone and chlorobenzene in 6 min. The annular column length was reduced to 22 cm to function as a sensor, with selected organic vapors exhibiting unique retention times and detection selectivity. The detection selectivity is determined by the analyte RI and the partition coefficient into the cladding. The calculated limit of detection (LOD) for benzene vapor is 0.03% by volume in nitrogen, and several chlorinated species had LOD values less than 1%. For binary mixtures of organic vapors, the detected response appears to be the linear combination of the two organic standards, suggesting that the annular column may be useful as a general approach for designing chemical sensors that incorporate separation and optical detection principles simultaneously.

  4. Rapid analysis of ethanol and water in commercial products using ionic liquid capillary gas chromatography with thermal conductivity detection and/or barrier discharge ionization detection.

    Science.gov (United States)

    Weatherly, Choyce A; Woods, Ross M; Armstrong, Daniel W

    2014-02-26

    Analysis of ethanol and water in consumer products is important in a variety of processes and often is mandated by regulating agencies. A method for the simultaneous quantitation of ethanol and water that is simple, accurate, precise, rapid, and cost-effective is demonstrated. This approach requires no internal standard for the quantitation of both ethanol and water at any/all levels in commercial products. Ionic liquid based gas chromatography (GC) capillary columns are used to obtain a fast analysis with high selectivity and resolution of water and ethanol. Typical run times are just over 3 min. Examination of the response range of water and ethanol with GC, thermal conductivity detection (TCD), and barrier ionization detection (BID) is performed. Quantitation of both ethanol and water in consumer products is accomplished with both TCD and BID GC detectors using a nonlinear calibration. Validation of method accuracy is accomplished by using standard reference materials.

  5. The Seepage Simulation of Single Hole and Composite Gas Drainage Based on LB Method

    Science.gov (United States)

    Chen, Yanhao; Zhong, Qiu; Gong, Zhenzhao

    2018-01-01

    Gas drainage is the most effective method to prevent and solve coal mine gas power disasters. It is very important to study the seepage flow law of gas in fissure coal gas. The LB method is a simplified computational model based on micro-scale, especially for the study of seepage problem. Based on fracture seepage mathematical model on the basis of single coal gas drainage, using the LB method during coal gas drainage of gas flow numerical simulation, this paper maps the single-hole drainage gas, symmetric slot and asymmetric slot, the different width of the slot combined drainage area gas flow under working condition of gas cloud of gas pressure, flow path diagram and flow velocity vector diagram, and analyses the influence on gas seepage field under various working conditions, and also discusses effective drainage method of the center hole slot on both sides, and preliminary exploration that is related to the combination of gas drainage has been carried on as well.

  6. Small sodium-to-gas leak behavior in relation to LMFBR leak detection system design

    International Nuclear Information System (INIS)

    Hopenfeld, J.; Taylor, G.R.; James, L.A.

    1976-01-01

    Various aspects of sodium-to-gas leaks which must be considered in the design of leak detection systems for LMFBR's are discussed. Attention is focused primarily on small, weeping type leaks. Corrosion rates of steels in fused sodium hydroxide and corrosion damage observed at the site of small leaks lead to the conclusion that the sodium-gas reaction products could attack the primary hot leg piping at rates up to 0.08 mils per hour. Based on theoretical considerations of the corrosion mechanism and on visual observations of pipe topography following small sodium leak tests, it is concluded that pipe damage will be manifested by the formation of small detectable leaks prior to the appearance of larger leaks. The case for uniform pipe corrosion along the pipe circumference or along a vertical section of the pipe is also examined. Using a theoretical model for the gravity flow of sodium and reaction products along the pipe surface and a mass transport controlled corrosion process, it is shown that below sodium leak rates of about 30 g/hr for the primary piping corrosion damage will not extend beyond one radius distance from the leak site. A method of estimating the time delay between the initiation of such leaks and the development of a larger leak due to increased pipe stresses resulting from corrosion is presented

  7. Refueling Stop Activity Detection and Gas Station Extraction Using Crowdsourcing Vehicle Trajectory Data

    Directory of Open Access Journals (Sweden)

    YANG Wei

    2017-07-01

    Full Text Available In view of the deficiencies of current surveying methods of gas station, an approach is proposed to extract gas station from vehicle traces. Firstly, the spatial-temporal characteristics of individual and collective refueling behavior of trajectory is analyzed from aspects of movement features and geometric patterns. Secondly, based on Stop/Move model, the velocity sequence linear clustering algorithm is proposed to extract refueling stop tracks. Finally, using the methods including Delaunay triangulation, Fourier shape recognition and semantic constraints to identify and extract gas station. An experiment using 7 days taxi GPS traces in Beijing verified the novel method. The experimental results of 482 gas stations are extracted and the correct rate achieves to 93.1%.

  8. Continuum removed band depth analysis for detecting the effects of natural gas, methane and ethane on maize reflectance

    NARCIS (Netherlands)

    Noomen, M.F.; Skidmore, A.K.; Meer, van der F.D.; Prins, H.H.T.

    2006-01-01

    It is known that natural gas in the soil affects vegetation health, which may be detected through analysis of reflectance spectra. Since natural gas is invisible, changes in the vegetation could potentially indicate gas leakage. Although it is known that gas in soil affects plant reflectance, the

  9. A method for the determination of volatile ammonia in air, using a nitrogen-cooled trap and fluorometric detection

    NARCIS (Netherlands)

    Westra, H.G.; Tigchelaar, R.G.; Berden, J.A.

    2001-01-01

    A quick, cheap, and accurate method for the determination of ammonia in air is described. Ammonia and water vapor are trapped simultaneously in a gas sampling tube cooled in liquid nitrogen. Subsequently ammonia is derivatized with o-phthaldialdehyde and determined using fluorescence detection. The

  10. Analysis of Off Gas From Disintegration Process of Graphite Matrix by Electrochemical Method

    International Nuclear Information System (INIS)

    Tian Lifang; Wen Mingfen; Chen Jing

    2010-01-01

    Using electrochemical method with salt solutions as electrolyte, some gaseous substances (off gas) would be generated during the disintegration of graphite from high-temperature gas-cooled reactor fuel elements. The off gas is determined to be composed of H 2 , O 2 , N 2 , CO 2 and NO x by gas chromatography. Only about 1.5% graphite matrix is oxidized to CO 2 . Compared to the direct burning-graphite method, less off gas,especially CO 2 , is generated in the disintegration process of graphite by electrochemical method and the treatment of off gas becomes much easier. (authors)

  11. Optimising the design of gas microstrip detectors for soft x-ray detection

    International Nuclear Information System (INIS)

    Bateman, J.; Barlow, R.; Derbyshire, G.

    2001-01-01

    This report describes development work in which systematic changes in the electrode pattern of a Gas Microstrip Detector are explored in the search for higher avalanche gains and enhanced stability. It is found that the width of the cathode structure is the main determinant of the detector stability. With the correct cathode width, gas gains of >50 000 are comfortably attainable with low detector noise so that x-rays can potentially be detected down to the limit of a single x-ray-produced photoelectron. (author)

  12. A selective and sensitive method for quantitation of lysergic acid diethylamide (LSD) in whole blood by gas chromatography-ion trap tandem mass spectrometry.

    Science.gov (United States)

    Libong, Danielle; Bouchonnet, Stéphane; Ricordel, Ivan

    2003-01-01

    A gas chromatography-ion trap tandem mass spectrometry (GC-ion trap MS-MS) method for detection and quantitation of LSD in whole blood is presented. The sample preparation process, including a solid-phase extraction step with Bond Elut cartridges, was performed with 2 mL of whole blood. Eight microliters of the purified extract was injected with a cold on-column injection method. Positive chemical ionization was performed using acetonitrile as reagent gas; LSD was detected in the MS-MS mode. The chromatograms obtained from blood extracts showed the great selectivity of the method. GC-MS quantitation was performed using lysergic acid methylpropylamide as the internal standard. The response of the MS was linear for concentrations ranging from 0.02 ng/mL (detection threshold) to 10.0 ng/mL. Several parameters such as the choice of the capillary column, the choice of the internal standard and that of the ionization mode (positive CI vs. EI) were rationalized. Decomposition pathways under both ionization modes were studied. Within-day and between-day stability were evaluated.

  13. Some methods of detection of atmospheric contamination by iodine 131

    International Nuclear Information System (INIS)

    Billard, Francois; Chevalier, Gerard; Gaillard, Pierre; Pradel, Jacques

    1964-01-01

    Due to the extensive use of iodine, risks of contamination by iodine 131 are increasing. Moreover, the increase of reactor power requires venting installations equipped with efficient safety filters which must be tested. The authors thus report the study of iodine trapping in filters, and its atmospheric detection and measurement. They report studies and achievements in the field of measurement of atmospheric pollution, and tests performed on iodine trapping by activated coals. After having outlined key qualities of an apparatus for atmospheric control, the authors indicate the various sampling methods. They discuss the method and calibration for the measurement of radioactivity of filters and coal which have trapped iodine 131. They discuss measurement sensitivity. They report how the efficiency of coals has been checked. They describe the experimental installation, and report the tests of some detectors of atmospheric contamination: sampling cartridges full of activated coal, gas mask cartridge, continuous control apparatus ('coffee machine' type), and detector of gaseous iodine. Appendices indicate the calculation of error on a cartridge counting rate, iodine generation methods (discontinuous method, continuous method) [fr

  14. Modeling of leak detection system for high pressure transmission system of natural gas

    International Nuclear Information System (INIS)

    Qureshi, S.A.; Paracha, Z.J.; Ali, A.

    2005-01-01

    Gas Industry can be considered as one of the most important industries in the economy of any country. Safe Transportation of Gas is thus considered to be vital because interruption of Supply of Gas to consumers not only causes domestic problems but also loss of revenue to country. Now most of power generation Sector has switched over their system to Natural Gas. So, interruption of supply to this sector can cause a lot of problems. This paper has provided assessment of technology approach and formulated this approach for Leak Detection Model in High Pressure Transmission system for current and future operations, which will improve the efficiency of any transmission company to a great extent. This model can be extremely helpful in conditions of Rupture Emergencies or Leakage because of corrosive conditions of Pipeline to manage the situation of resources in pipeline network. Any exceptional readings or messages should alert the user to the fact that something is wrong with the system. Such a system helps a lot in the safe and efficient management of pipeline network. The data and information provided by the Leak Detection System applications will allow for efficient and safe pipeline operation maximizing profitability over the pipeline's service lifetime. (author)

  15. Emission quantification using the tracer gas dispersion method: The influence of instrument, tracer gas species and source simulation

    DEFF Research Database (Denmark)

    Delre, Antonio; Mønster, Jacob; Samuelsson, Jerker

    2018-01-01

    The tracer gas dispersion method (TDM) is a remote sensing method used for quantifying fugitive emissions by relying on the controlled release of a tracer gas at the source, combined with concentration measurements of the tracer and target gas plumes. The TDM was tested at a wastewater treatment...... plant for plant-integrated methane emission quantification, using four analytical instruments simultaneously and four different tracer gases. Measurements performed using a combination of an analytical instrument and a tracer gas, with a high ratio between the tracer gas release rate and instrument...... precision (a high release-precision ratio), resulted in well-defined plumes with a high signal-to-noise ratio and a high methane-to-tracer gas correlation factor. Measured methane emission rates differed by up to 18% from the mean value when measurements were performed using seven different instrument...

  16. Standard test method for determining whether gas-leak-detector fluid solutions can cause stress corrosion cracking of brass alloys

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers an accelerated test method for evaluating the tendency of gas leak detection fluids (LDFs) to cause stress corrosion cracking (SCC) of brass components in compressed gas service. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

  17. A comparison of moving object detection methods for real-time moving object detection

    Science.gov (United States)

    Roshan, Aditya; Zhang, Yun

    2014-06-01

    Moving object detection has a wide variety of applications from traffic monitoring, site monitoring, automatic theft identification, face detection to military surveillance. Many methods have been developed across the globe for moving object detection, but it is very difficult to find one which can work globally in all situations and with different types of videos. The purpose of this paper is to evaluate existing moving object detection methods which can be implemented in software on a desktop or laptop, for real time object detection. There are several moving object detection methods noted in the literature, but few of them are suitable for real time moving object detection. Most of the methods which provide for real time movement are further limited by the number of objects and the scene complexity. This paper evaluates the four most commonly used moving object detection methods as background subtraction technique, Gaussian mixture model, wavelet based and optical flow based methods. The work is based on evaluation of these four moving object detection methods using two (2) different sets of cameras and two (2) different scenes. The moving object detection methods have been implemented using MatLab and results are compared based on completeness of detected objects, noise, light change sensitivity, processing time etc. After comparison, it is observed that optical flow based method took least processing time and successfully detected boundary of moving objects which also implies that it can be implemented for real-time moving object detection.

  18. A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

    Energy Technology Data Exchange (ETDEWEB)

    Yudaya Sivathanu; Jongmook Lim; Vinoo Narayanan; Seonghyeon Park

    2005-12-07

    The objective of this project is to design, fabricate and demonstrate a cost effective, multi-spectral scanner for natural gas leak detection in transmission and distribution pipelines. During the first year of the project, a laboratory version of the multi-spectral scanner was designed, fabricated, and tested at EnUrga Inc. The multi-spectral scanner was also evaluated using a blind Department of Energy study at the Rocky Mountain Oilfield Testing Center. The performance of the scanner was inconsistent during the blind study. However, most of the leaks were outside the view of the multi-spectral scanner that was developed during the first year of the project. Therefore, a definite evaluation of the capability of the scanner was not obtained. Despite the results, sufficient number of plumes was detected fully confirming the feasibility of the multi-spectral scanner. During the second year, the optical design of the scanner was changed to improve the sensitivity of the system. Laboratory tests show that the system can reliably detect small leaks (20 SCFH) at 30 to 50 feet. A prototype scanner was built and evaluated during the second year of the project. Only laboratory evaluations were completed during the second year. The laboratory evaluations show the feasibility of using the scanner to determine natural gas pipeline leaks. Further field evaluations and optimization of the scanner are required before commercialization of the scanner can be initiated.

  19. Detection of Stimulants and Narcotics by Liquid Chromatography-Tandem Mass Spectrometry and Gas Chromatography-Mass Spectrometry for Sports Doping Control.

    Science.gov (United States)

    Ahrens, Brian D; Kucherova, Yulia; Butch, Anthony W

    2016-01-01

    Sports drug testing laboratories are required to detect several classes of compounds that are prohibited at all times, which include anabolic agents, peptide hormones, growth factors, beta-2 agonists, hormones and metabolic modulators, and diuretics/masking agents. Other classes of compounds such as stimulants, narcotics, cannabinoids, and glucocorticoids are also prohibited, but only when an athlete is in competition. A single class of compounds can contain a large number of prohibited substances and all of the compounds should be detected by the testing procedure. Since there are almost 70 stimulants on the prohibited list it can be a challenge to develop a single screening method that will optimally detect all the compounds. We describe a combined liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS) testing method for detection of all the stimulants and narcotics on the World Anti-Doping Agency prohibited list. Urine for LC-MS/MS testing does not require sample pretreatment and is a direct dilute and shoot method. Urine samples for the GC-MS method require a liquid-liquid extraction followed by derivatization with trifluoroacetic anhydride.

  20. Simultaneous determination of organophosphorous insecticides in bean samples by gas chromatography - flame photometric detection

    Directory of Open Access Journals (Sweden)

    Keyller Bastos Borges

    2014-02-01

    Full Text Available The indiscriminate use of organophosphorous pesticides (OPPs in crops may leave residues in food and may cause poisoning in the applicators. A method was developed for the determination of five OPPs in bean samples by Gas Chromatography-Flame Photometric Detection (GC-FPD. Validation parameters comprised linearity between 0.24 and 8.56 μg g-1 (r = 0.9985 for diazinon; 0.23 and 8.14 μg g-1 (r = 0.9959 for methyl parathion; 0.28 and 10.25 μg g-1 (r = 0.9987 for methyl pirimiphos; 0.52 and 18.87 μg g-1 (r = 0.9955 for malathion; 0.86 and 13.67 μg g-1 (r = 0.9919 for ethion. The limits of quantification (equal to those of detection were the lowest rates of ranges mentioned above for each compound. The extraction method showed approximately 95% recovery, with CV% < 15%. Although twenty-eight bean samples obtained in the southern region of the state of Minas Gerais,Brazil, were analyzed, they failed to match any of the OPPs under analysis. The absence of OPPs in the samples could be due to the degradation that occurred between the use of OPPs and bean commercialization, levels below the detection /quantification limits and the non-use of OPPs in bean cultivation.

  1. Rapid methods for detection of bacteria

    DEFF Research Database (Denmark)

    Corfitzen, Charlotte B.; Andersen, B.Ø.; Miller, M.

    2006-01-01

    Traditional methods for detection of bacteria in drinking water e.g. Heterotrophic Plate Counts (HPC) or Most Probable Number (MNP) take 48-72 hours to give the result. New rapid methods for detection of bacteria are needed to protect the consumers against contaminations. Two rapid methods...

  2. Thermal detection mechanism of SiC based hydrogen resistive gas sensors

    Science.gov (United States)

    Fawcett, Timothy J.; Wolan, John T.; Lloyd Spetz, Anita; Reyes, Meralys; Saddow, Stephen E.

    2006-10-01

    Silicon carbide (SiC) resistive hydrogen gas sensors have been fabricated and tested. Planar NiCr contacts were deposited on a thin 3C-SiC epitaxial film grown on thin Si wafers bonded to polycrystalline SiC substrates. At 673K, up to a 51.75±0.04% change in sensor output current and a change in the device temperature of up to 163.1±0.4K were demonstrated in response to 100% H2 in N2. Changes in device temperature are shown to be driven by the transfer of heat from the device to the gas, giving rise to a thermal detection mechanism.

  3. Gas measuring apparatus with standardization means, and method therefor

    International Nuclear Information System (INIS)

    Typpo, P.M.

    1980-01-01

    An apparatus and a method for standardizing a gas measuring device has a source capable of emitting a beam of radiation aligned to impinge a detector. A housing means encloses the beam. The housing means has a plurality of apertures permitting the gas to enter the housing means, to intercept the beam, and to exit from the housing means. The device further comprises means for closing the apertures and a means for purging said gas from the housing means

  4. High Temperature and High Sensitive NOx Gas Sensor with Hetero-Junction Structure using Laser Ablation Method

    Science.gov (United States)

    Gao, Wei; Shi, Liqin; Hasegawa, Yuki; Katsube, Teruaki

    In order to develop a high temperature (200°C˜400°C) and high sensitive NOx gas sensor, we developed a new structure of SiC-based hetero-junction device Pt/SnO2/SiC/Ni, Pt/In2O3/SiC/Ni and Pt/WO3/SiC/Ni using a laser ablation method for the preparation of both metal (Pt) electrode and metal-oxide film. It was found that Pt/In2O3/SiC/Ni sensor shows higher sensitivity to NO2 gas compared with the Pt/SnO2/SiC/Ni and Pt/WO3/SiC/Ni sensor, whereas the Pt/WO3/SiC/Ni sensor had better sensitivity to NO gas. These results suggest that selective detection of NO and NO2 gases may be obtained by choosing different metal oxide films.

  5. A review on measuring methods of gas-liquid flow rates

    International Nuclear Information System (INIS)

    Minemura, Kiyoshi; Yamashita, Masato

    2000-01-01

    This paper presents a review on the state of current measuring techniques for gas-liquid multiphase flow rates. After briefly discussing the basic idea on measuring methods for single-phase and two-phase flows, existing methods for the two-phase flow rates are classified into several types, that is, with or without a homogenizing device, single or combined method of several techniques, with intrusive or non-intrusive sensors, and physical or software method. Each methods are comparatively reviewed in view of measuring accuracy and manageability. Its scope also contains the techniques developed for petroleum-gas-water flow rates. (author)

  6. Method of measuring density of gas in a vessel

    International Nuclear Information System (INIS)

    Shono, Kosuke.

    1981-01-01

    Purpose: To accurately measure the density of a gas in a vessel even at a loss-of-coolant accident in a BWR type reactor. Method: When at least one of the pressure or the temperature of gas in a vessel exceeds the usable range of a gas density measuring instrument due to a loss-of-coolant accident, the gas in the vessel is sampled, and the pressure or the temperature of the sampled gas are measured by matching them to the usable conditions of the gas density measuring instrument. Hydrogen gas and oxygen gas densities exceeding the usable range of the gas density measuring instrument are calculated by the following formulae based on the measured values. C'sub(O) = P sub(T).C sub(O)/P sub(T), C'sub(H) = C''sub(H).C'sub(O)/C''sub(O), where C sub(O), P sub(T), C'sub(H) represent the oxygen density, the total pressure and the hydrogen density of the internal pressure gas of the vessel after the respective gas density measuring instruments exceed the usable ranges; C sub(O), P sub(T) represent the oxygen density and the total pressure of the gas in the vessel before the gas density measuring instruments exceeded the usable range, and C''sub(H), C''sub(O) represent the hydrogen density and oxygen density of the respective sampled gases. (Kamimura, M.)

  7. Acousto-Optic Q-Switched Fiber Laser-Based Intra-Cavity Photoacoustic Spectroscopy for Trace Gas Detection.

    Science.gov (United States)

    Zhang, Qinduan; Chang, Jun; Wang, Qiang; Wang, Zongliang; Wang, Fupeng; Qin, Zengguang

    2017-12-25

    We proposed a new method for gas detection in photoacoustic spectroscopy based on acousto-optic Q-switched fiber laser by merging a transmission PAS cell (resonant frequency f ₀ = 5.3 kHz) inside the fiber laser cavity. The Q-switching was achieved by an acousto-optic modulator, achieving a peak pulse power of ~679 mW in the case of the acousto-optic modulation signal with an optimized duty ratio of 10%. We used a custom-made fiber Bragg grating with a central wavelength of 1530.37 nm (the absorption peak of C₂H₂) to select the laser wavelength. The system achieved a linear response (R² = 0.9941) in a concentration range from 400 to 7000 ppmv, and the minimum detection limit compared to that of a conventional intensity modulation system was enhanced by 94.2 times.

  8. Detection of oral HPV infection - Comparison of two different specimen collection methods and two HPV detection methods.

    Science.gov (United States)

    de Souza, Marjorie M A; Hartel, Gunter; Whiteman, David C; Antonsson, Annika

    2018-04-01

    Very little is known about the natural history of oral HPV infection. Several different methods exist to collect oral specimens and detect HPV, but their respective performance characteristics are unknown. We compared two different methods for oral specimen collection (oral saline rinse and commercial saliva kit) from 96 individuals and then analyzed the samples for HPV by two different PCR detection methods (single GP5+/6+ PCR and nested MY09/11 and GP5+/6+ PCR). For the oral rinse samples, the oral HPV prevalence was 10.4% (GP+ PCR; 10% repeatability) vs 11.5% (nested PCR method; 100% repeatability). For the commercial saliva kit samples, the prevalences were 3.1% vs 16.7% with the GP+ PCR vs the nested PCR method (repeatability 100% for both detection methods). Overall the agreement was fair or poor between samples and methods (kappa 0.06-0.36). Standardizing methods of oral sample collection and HPV detection would ensure comparability between future oral HPV studies. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Experimental study on the detection of free fluids and gases in waste packages by acoustic methods

    International Nuclear Information System (INIS)

    Eisenblaetter, J.; Schaefer, P.; Weib, R.

    1992-01-01

    The objective of the project was to evaluate the potential and the limits of various nondestructive methods for testing the contents of 200-litre drums filled with radioactive waste. The following test problems were to be studied: 1. Detection of free water on the surface of the waste matrix (concrete); 2. Determination of the waste matrix level; 3. Determination of internal gas pressure. The following methods were found to be suitable: For Test problem 1: Measurement of Lamb wave attenuation, Acoustic impedance measurement (AIM) and Analysis of swash sound; For Test problem 2: Acoustic impedance measurement (AIM) and Measurement of Lamb wave attenuation; For Test problem 3: A method of pressure compensation and Analysis of cover resonances after striking the cover. It was not possible, however, to detect the concrete level by localisation of friction points using acoustic emission methods. 53 figs

  10. Electrochemical and Infrared Absorption Spectroscopy Detection of SF₆ Decomposition Products.

    Science.gov (United States)

    Dong, Ming; Zhang, Chongxing; Ren, Ming; Albarracín, Ricardo; Ye, Rixin

    2017-11-15

    Sulfur hexafluoride (SF₆) gas-insulated electrical equipment is widely used in high-voltage (HV) and extra-high-voltage (EHV) power systems. Partial discharge (PD) and local heating can occur in the electrical equipment because of insulation faults, which results in SF₆ decomposition and ultimately generates several types of decomposition products. These SF₆ decomposition products can be qualitatively and quantitatively detected with relevant detection methods, and such detection contributes to diagnosing the internal faults and evaluating the security risks of the equipment. At present, multiple detection methods exist for analyzing the SF₆ decomposition products, and electrochemical sensing (ES) and infrared (IR) spectroscopy are well suited for application in online detection. In this study, the combination of ES with IR spectroscopy is used to detect SF₆ gas decomposition. First, the characteristics of these two detection methods are studied, and the data analysis matrix is established. Then, a qualitative and quantitative analysis ES-IR model is established by adopting a two-step approach. A SF₆ decomposition detector is designed and manufactured by combining an electrochemical sensor and IR spectroscopy technology. The detector is used to detect SF₆ gas decomposition and is verified to reliably and accurately detect the gas components and concentrations.

  11. Simultaneous determination of methanol, acetaldehyde, acetone, and ethanol in human blood by gas chromatography with flame ionization detection.

    Science.gov (United States)

    Schlatter, J; Chiadmi, F; Gandon, V; Chariot, P

    2014-01-01

    Methanol, acetaldehyde, acetone, and ethanol, which are commonly used as biomarkers of several diseases, in acute intoxications, and forensic settings, can be detected and quantified in biological fluids. Gas chromatography (GC)-mass spectrometry techniques are complex, require highly trained personnel and expensive materials. Gas chromatographic determinations of ethanol, methanol, and acetone have been reported in one study with suboptimal accuracy. Our objective was to improve the assessment of these compounds in human blood using GC with flame ionization detection. An amount of 50 µl of blood was diluted with 300 µl of sterile water, 40 µl of 10% sodium tungstate, and 20 µl of 1% sulphuric acid. After centrifugation, 1 µl of the supernatant was injected into the gas chromatograph. We used a dimethylpolysiloxane capillary column of 30 m × 0.25 mm × 0.25 µm. We observed linear correlations from 7.5 to 240 mg/l for methanol, acetaldehyde, and acetone and from 75 to 2400 mg/l for ethanol. Precision at concentrations 15, 60, and 120 mg/l for methanol, acetaldehyde, and acetone and 150, 600, and 1200 mg/ml for ethanol were 0.8-6.9%. Ranges of accuracy were 94.7-98.9% for methanol, 91.2-97.4% for acetaldehyde, 96.1-98.7% for acetone, and 105.5-111.6% for ethanol. Limits of detection were 0.80 mg/l for methanol, 0.61 mg/l for acetaldehyde, 0.58 mg/l for acetone, and 0.53 mg/l for ethanol. This method is suitable for routine clinical and forensic practices.

  12. Study on the inside gas flow visualization of oxygen sensor cover; Kashika ni yoru O2 sensor cover nai no gas nagare hyoka

    Energy Technology Data Exchange (ETDEWEB)

    Hocho, S; Mitsuishi, Y; Inagaki, M [Nippon Soken, Inc., Tokyo (Japan); Hamaguchi, S; Mizusawa, K [Toyota Motor Corp., Aichi (Japan)

    1997-10-01

    In order to make clear the difference of the response time between the oxygen sensors with different protection covers, we visualized gas flow inside of sensor covers by means of two experimental methods: One is `Smoke Suspension Method` using liquid paraffin vapor as the smoke. With smoke suspension method, we detected the streamlines inside of the covers. The other is `Color Reaction Method` using the reaction of phenolphthalein and NH3 gas. With color reaction method, we confirmed the streamline inside of the cover and furthermore detected the difference of the response time of each sensor. 3 refs., 7 figs., 1 tab.

  13. Methods of analysis-Determination of pesticides in sediment using gas chromatography/mass spectrometry

    Science.gov (United States)

    Hladik, Michelle; McWayne, Megan M.

    2012-01-01

    A method for the determination of 119 pesticides in environmental sediment samples is described. The method was developed by the U.S. Geological Survey (USGS) in support of the National Water Quality Assessment (NAWQA) Program. The pesticides included in this method were chosen through prior prioritization. Herbicides, insecticides, and fungicides along with degradates are included in this method and span a variety of chemical classes including, but not limited to, chloroacetanilides, organochlorines, organophosphates, pyrethroids, triazines, and triazoles. Sediment samples are extracted by using an accelerated solvent extraction system (ASE®, and the compounds of interest are separated from co-extracted matrix interferences (including sulfur) by passing the extracts through high performance liquid chromatography (HPLC) with gel-permeation chromatography (GPC) along with the use of either stacked graphitized carbon and alumina solid-phase extraction (SPE) cartridges or packed Florisil®. Chromatographic separation, detection, and quantification of the pesticides from the sediment-sample extracts are done by using gas chromatography with mass spectrometry (GC/MS). Recoveries in test sediment samples fortified at 10 micrograms per kilogram (μg/kg) dry weight ranged from 75 to 102 percent; relative standard deviations ranged from 3 to 13 percent. Method detection limits (MDLs), calculated by using U.S. Environmental Protection Agency procedures (40 CFR 136, Appendix B), ranged from 0.6 to 3.4 μg/kg dry weight.

  14. Gas Chromatic Mass Spectrometer

    Science.gov (United States)

    Wey, Chowen

    1995-01-01

    Gas chromatograph/mass spectrometer (GC/MS) used to measure and identify combustion species present in trace concentration. Advanced extractive diagnostic method measures to parts per billion (PPB), as well as differentiates between different types of hydrocarbons. Applicable for petrochemical, waste incinerator, diesel transporation, and electric utility companies in accurately monitoring types of hydrocarbon emissions generated by fuel combustion, in order to meet stricter environmental requirements. Other potential applications include manufacturing processes requiring precise detection of toxic gaseous chemicals, biomedical applications requiring precise identification of accumulative gaseous species, and gas utility operations requiring high-sensitivity leak detection.

  15. Study of the MWPC gas gain behaviour as a function of the gas pressure and temperature

    CERN Document Server

    Pinci, D

    2005-01-01

    The Muon System of the LHCb experiment is composed of five detection stations (M1-M5) equipped with 1368 Multi-Wire Proportional Chambers (MWPC) and 24 Triple-GEM detectors. The Multi Wire Proportional Chamber (MWPC) performances (detection efficiency, time resolution, pad-cluster size and ageing properties) are heavily dependent on the gas gain. The chamber gain depends on the gas density and therefore on the gas temperature and pressure. The impact of the environmental parameters on the MWPC gain has been studied in detail. The results, togheter with a simple method proposed to account for the gain variations, are reported in this note. The absolute gas gain at the testing voltage of 2750 V was also measured to be (1.2 +- 0.1)*10^5.

  16. A comprehensive environmental impact assessment method for shale gas development

    Directory of Open Access Journals (Sweden)

    Renjin Sun

    2015-03-01

    Full Text Available The great success of US commercial shale gas exploitation stimulates the shale gas development in China, subsequently, the corresponding supporting policies were issued in the 12th Five-Year Plan. But from the experience in the US shale gas development, we know that the resulted environmental threats are always an unavoidable issue, but no uniform and standard evaluation system has yet been set up in China. The comprehensive environment refers to the combination of natural ecological environment and external macro-environment. In view of this, we conducted a series of studies on how to set up a comprehensive environmental impact assessment system as well as the related evaluation methodology and models. First, we made an in-depth investigation into shale gas development procedures and any possible environmental impacts, and then compared, screened and modified environmental impact assessment methods for shale gas development. Also, we established an evaluating system and assessment models according to different status of the above two types of environment: the correlation matrix method was employed to assess the impacts on natural ecological environment and the optimization distance method was modified to evaluate the impacts on external macro-environment. Finally, we substitute the two subindexes into the comprehensive environmental impact assessment model and achieved the final numerical result of environmental impact assessment. This model can be used to evaluate if a shale gas project has any impact on environment, compare the impacts before and after a shale gas development project, or the impacts of different projects.

  17. A gas chromatography-mass spectrometry (GC-MS) method for the detection and quantitation of monofluoroacetate in plants toxic to livestock

    Science.gov (United States)

    Monofluoroacetate (MFA) is a potent toxin that occurs in over 50 plant species in Africa, Australia, and South America and is responsible for significant livestock deaths in these regions. A gas chromatography–mass spectrometry (GC-MS) method for the analysis of MFA in plants based on the derivatiza...

  18. In Vitro Androgen Bioassays as a Detection Method for Designer Androgens

    Directory of Open Access Journals (Sweden)

    Alison K. Heather

    2013-02-01

    Full Text Available Androgens are the class of sex steroids responsible for male sexual characteristics, including increased muscle mass and decreased fat mass. Illicit use of androgen doping can be an attractive option for those looking to enhance sporting performance and/or physical appearance. The use of in vitro bioassays to detect androgens, especially designer or proandrogens, is becoming increasingly important in combating androgen doping associated with nutritional supplements. The nutritional sports supplement market has grown rapidly throughout the past decade. Many of these supplements contain androgens, designer androgens or proandrogens. Many designer or proandrogens cannot be detected by the standard highly-sensitive screening methods such as gas chromatography-mass spectrometry because their chemical structure is unknown. However, in vitro androgen bioassays can detect designer and proandrogens as these assays are not reliant on knowing the chemical structure but instead are based on androgen receptor activation. For these reasons, it may be advantageous to use routine androgen bioassay screening of nutraceutical samples to help curb the increasing problem of androgen doping.

  19. Some methods for the detection of fissionable matter; Quelques methodes de detection des corps fissiles

    Energy Technology Data Exchange (ETDEWEB)

    Guery, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-03-01

    A number of equipments or processes allowing to detect uranium or plutonium in industrial plants, and in particular to measure solution concentrations, are studied here. Each method has its own field of applications and has its own performances, which we have tried to define by calculations and by experiments. The following topics have been treated: {gamma} absorptiometer with an Am source, detection test by neutron multiplication, apparatus for the measurement of the {alpha} activity of a solution, fissionable matter detection by {gamma} emission, fissionable matter detection by neutron emission. (author) [French] On examine ici plusieurs appareils ou procedes qui permettent de detecter l'uranium ou le plutonium dans les installations industrielles, et en particulier de mesurer les concentrations de solutions. Chacune des methodes a son domaine d'application et ses performances, qu'on a tente de definir par le calcul et par des experiences. Les sujets traites sont les suivants: absorptiometre {gamma} a source d'americium, essais de detection par multiplication neutronique, appareil de mesure de l'activite {alpha} d'une solution, detection des matieres fissiles par leur emission {gamma}, detection des matieres fissiles par leur emission neutronique. (auteur)

  20. An Entropy-Based Network Anomaly Detection Method

    Directory of Open Access Journals (Sweden)

    Przemysław Bereziński

    2015-04-01

    Full Text Available Data mining is an interdisciplinary subfield of computer science involving methods at the intersection of artificial intelligence, machine learning and statistics. One of the data mining tasks is anomaly detection which is the analysis of large quantities of data to identify items, events or observations which do not conform to an expected pattern. Anomaly detection is applicable in a variety of domains, e.g., fraud detection, fault detection, system health monitoring but this article focuses on application of anomaly detection in the field of network intrusion detection.The main goal of the article is to prove that an entropy-based approach is suitable to detect modern botnet-like malware based on anomalous patterns in network. This aim is achieved by realization of the following points: (i preparation of a concept of original entropy-based network anomaly detection method, (ii implementation of the method, (iii preparation of original dataset, (iv evaluation of the method.

  1. Holographic method for site-resolved detection of a 2D array of ultracold atoms

    Science.gov (United States)

    Hoffmann, Daniel Kai; Deissler, Benjamin; Limmer, Wolfgang; Hecker Denschlag, Johannes

    2016-08-01

    We propose a novel approach to site-resolved detection of a 2D gas of ultracold atoms in an optical lattice. A near-resonant laser beam is coherently scattered by the atomic array, and after passing a lens its interference pattern is holographically recorded by superimposing it with a reference laser beam on a CCD chip. Fourier transformation of the recorded intensity pattern reconstructs the atomic distribution in the lattice with single-site resolution. The holographic detection method requires only about two hundred scattered photons per atom in order to achieve a high reconstruction fidelity of 99.9 %. Therefore, additional cooling during detection might not be necessary even for light atomic elements such as lithium. Furthermore, first investigations suggest that small aberrations of the lens can be post-corrected in imaging processing.

  2. A Statistical Framework for Automatic Leakage Detection in Smart Water and Gas Grids

    Directory of Open Access Journals (Sweden)

    Marco Fagiani

    2016-08-01

    Full Text Available In the last few years, due to the technological improvement of advanced metering infrastructures, water and natural gas grids can be regarded as smart-grids, similarly to power ones. However, considering the number of studies related to the application of computational intelligence to distribution grids, the gap between power grids and water/gas grids is notably wide. For this purpose, in this paper, a framework for leakage identification is presented. The framework is composed of three sections aimed at the extraction and the selection of features and at the detection of leakages. A variation of the Sequential Feature Selection (SFS algorithm is used to select the best performing features within a set, including, also, innovative temporal ones. The leakage identification is based on novelty detection and exploits the characterization of a normality model. Three statistical approaches, The Gaussian Mixture Model (GMM, Hidden Markov Model (HMM and One-Class Support Vector Machine (OC-SVM, are adopted, under a comparative perspective. Both residential and office building environments are investigated by means of two datasets. One is the Almanac of Minutely Power dataset (AMPds, and it provides water and gas data consumption at 1, 10 and 30 min of time resolution; the other is the Department of International Development (DFID dataset, and it provides water and gas data consumption at 30 min of time resolution. The achieved performance, computed by means of the Area Under the Curve (AUC, reaches 90 % in the office building case study, thus confirming the suitability of the proposed approach for applications in smart water and gas grids.

  3. Development of evaluation method of long-term confinement performance for canister. Part 1. Fundamental study of analyses method for helium leak detection

    International Nuclear Information System (INIS)

    Takeda, Hirofumi; Toriu, Daisuke; Ushijima, Satoru

    2014-01-01

    The storage management of spent nuclear fuel for ageing degradation is becoming a global issue, so we researched the present status and measures of the management in each country. In particular, for the concrete cask storage, a leak detecting method that detects the leak from the change in canister surface temperature has been proposed. We performed thermal hydraulics analysis to clarify the phenomenon and to work toward practical use of the detecting method. For analyzing the leak phenomenon with high accuracy, it is necessary to stably solve the low-Mach number flow problem considering compressibility of gas. Therefore, we originally modified the conventional compressible flow solution method and proposed a new method which is applicable to thermo-hydraulics phenomenon and satisfies the mass conservation law with high accuracy. For the cavity natural convection analysis, the mass conservation in a calculating area was satisfied with high accuracy. As for the analysis of leak from the cavity, a helium leak phenomenon could be calculated stably by using the proposed method. The pressure in the cavity and the change of the mass could be also analyzed validly. As for the temperature distribution in the cavity, it was confirmed that the temperature changes before and after the leak. (author)

  4. Gas separation techniques in nuclear facilities

    International Nuclear Information System (INIS)

    Hioki, Hideaki; Morisue, Tetsuo; Ohno, Masayoshi

    1983-01-01

    The literatures concerning the gas separation techniques which are applied to the waste gases generated from nuclear power plants and nuclear fuel reprocessing plants, uranium enrichment and the instrumentation of nuclear facilities are reviewed. The gas permeability and gas separation performance of membranes are discussed in terms of rare gas separation. The investigation into the change of the gas permeability and mechanical properties of membranes with exposure to radiation is reported. The theoretical investigation of the separating cells used for the separation of rare gas and the development of various separating cells are described, and the theoretical and experimental investigations concerning rare gas separation using cascades are described. The application of membrane method to nuclear facilities is explained showing the examples of uranium enrichment, the treatment of waste gases from nuclear reactor buildings and nuclear fuel reprocessing plants, the monitoring of low level β-emitters in stacks, the detection of failed fuels and the detection of water leak in fast breeder reactors. (Yoshitake, I.)

  5. Development of a new microextraction method based on elevated temperature dispersive liquid-liquid microextraction for determination of triazole pesticides residues in honey by gas chromatography-nitrogen phosphorus detection.

    Science.gov (United States)

    Farajzadeh, Mir Ali; Mogaddam, Mohammad Reza Afshar; Ghorbanpour, Houshang

    2014-06-20

    In the present study, a rapid, highly efficient, and reliable sample preparation method named "elevated temperature dispersive liquid-liquid microextraction" followed by gas chromatography-nitrogen-phosphorus detection was developed for the extraction, preconcentration, and determination of five triazole pesticides (penconazole, hexaconazole, diniconazole, tebuconazole, and difenoconazole) in honey samples. In this method the temperature of high-volume aqueous phase was adjusted at an elevated temperature and then a disperser solvent containing an extraction solvent was rapidly injected into the aqueous phase. After cooling to room temperature, the phase separation was accelerated by centrifugation. Various parameters affecting the extraction efficiency such as type and volume of the extraction and disperser solvents, temperature, salt addition, and pH were evaluated. Under the optimum extraction conditions, the method resulted in low limits of detection and quantification within the range 0.05-0.21ngg(-1) in honey (15-70ngL(-1) in solution) and 0.15-1.1ngg(-1) in honey (45-210ngL(-1) in solution), respectively. Enrichment factors and extraction recoveries were in the ranges of 1943-1994 and 97-100%, respectively. The method precision was evaluated at 1.5ngg(-1) of each analyte, and the relative standard deviations were found to be less than 4% for intra-day (n=6) and less than 6% for inter-days. The method was successfully applied to the analysis of honey samples and difenoconazole was determined at ngg(-1) levels. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Analysis of anabolic steroids in body fluids by capillary gas chromatography with a two-channel detection system and a computer.

    Science.gov (United States)

    Uralets, V P; Semenova, V A; Yakushin, M A; Semenov, V A

    1983-11-25

    A method is described for analysis of multi-component mixtures of steroid metabolites in biological fluids by means of capillary gas chromatography with glass and fused-silica columns and simultaneous detection of methoxylamine-trimethylsilyl derivatives with universal flame-ionization and selective nitrogen alkali flameionization detectors. A data system was applied to the on-line treatment of the results. Computer programs were designed for precise calculation of Kováts retention indices from the known values for selected natural urinary steroids. The programs allow the selection of nitrogen-containing components, normalized chromatogram plotting for both detection channels and qualitative and quantitative analysis. Results are presented on the detection of metabolites of methandrostenolone, 17 alpha-methyltestosterone, 19-nortestosterone and fluoxymesterone.

  7. An in situ method for real-time monitoring of soil gas diffusivity

    Science.gov (United States)

    Laemmel, Thomas; Maier, Martin; Schack-Kirchner, Helmer; Lang, Friederike

    2016-04-01

    Soil aeration is an important factor for the biogeochemistry of soils. Generally, gas exchange between soil and atmosphere is assumed to be governed by molecular diffusion and by this way fluxes can be calculated using by Fick's Law. The soil gas diffusion coefficient DS represents the proportional factor between the gas flux and the gas concentration gradient in the soil and reflects the ability of the soil to "transport passively" gas through the soil. One common way to determine DS is taking core samples in the field and measuring DS in the lab. Unfortunately this method is destructive and laborious and it can only reflect a small fraction of the whole soil. As a consequence, uncertainty about the resulting effective diffusivity on the profile scale, i.e. the real aeration status remains. We developed a method to measure and monitor DS in situ. The set-up consists of a custom made gas sampling device, the continuous injection of an inert tracer gas and inverse gas transport modelling in the soil. The gas sampling device has seven sampling depths (from 0 to -43 cm of depth) and can be easily installed into vertical holes drilled by an auger, which allows for fast installation of the system. Helium (He) as inert tracer gas was injected continuously at the lower end of the device. The resulting steady state distribution of He was used to deduce the DS depth distribution of the soil. For Finite Element Modeling of the gas-sampling-device/soil system the program COMSOL was used. We tested our new method both in the lab and in a field study and compared the results with a reference lab method using soil cores. DS profiles obtained by our in-situ method were consistent with DS profiles determined based on soil core analyses. Soil gas profiles could be measured with a temporal resolution of 30 minutes. During the field study, there was an important rain event and we could monitor the decrease in soil gas diffusivity in the top soil due to water infiltration. The effect

  8. Method for online measurement of the CHON composition of raw gas from biomass gasifier

    International Nuclear Information System (INIS)

    Neves, Daniel; Thunman, Henrik; Tarelho, Luís; Larsson, Anton; Seemann, Martin; Matos, Arlindo

    2014-01-01

    Highlights: • Measuring the CHON composition of a raw gas by current methods is challenging. • An alternative method is to burn the raw gas before measuring the CHON composition. • The CHON contents of the raw gas can be accurately measured by the alternative method. • Measuring the CHON contents of the raw gas is now performed in a “one-step” analysis. • The new method is used to evaluate the operation of a dual fluidised bed gasifier. - Abstract: For unattended biomass gasification processes, rapid methods for monitoring the elemental composition (CHON) of the raw gas leaving the gasifier are needed. Conventional methods rely on time-consuming and costly laboratory procedures for analysing the condensable part of the raw gas. An alternative method, presented in this work, assesses the CHON composition of raw gas in a “one step” analysis without the need to previously characterise its chemical species composition. Our method is based on the quantitative conversion of a raw gas of complex chemical composition into CO 2 , H 2 O, and N 2 in a small combustor. The levels of these simple species can be measured with high accuracy and good time resolution, and the CHON composition of the raw gas can be determined from the mass balance across the combustor. To evaluate this method, an online combustion facility was built and used to analyse the raw gas from the Chalmers 2-MW th dual fluidised bed steam gasifier. Test runs of the developed facility demonstrated complete combustion of the raw gas and the measurements were both fast and reliable. The new method used in combination with zero-dimensional reactor modelling provides valuable data for the operational monitoring of gasification processes, such as the degree of fuel conversion, composition of the char exiting the gasifier, oxygen transport by catalytic bed material, and amount of condensables in raw gas

  9. Near-infrared incoherent broadband cavity enhanced absorption spectroscopy (NIR-IBBCEAS) for detection and quantification of natural gas components.

    Science.gov (United States)

    Prakash, Neeraj; Ramachandran, Arun; Varma, Ravi; Chen, Jun; Mazzoleni, Claudio; Du, Ke

    2018-06-28

    The principle of near-infrared incoherent broadband cavity enhanced absorption spectroscopy was employed to develop a novel instrument for detecting natural gas leaks as well as for testing the quality of natural gas mixtures. The instrument utilizes the absorption features of methane, butane, ethane, and propane in the wavelength region of 1100 nm to 1250 nm. The absorption cross-section spectrum in this region for methane was adopted from the HITRAN database, and those for the other three gases were measured in the laboratory. A singular-value decomposition (SVD) based analysis scheme was employed for quantifying methane, butane, ethane, and propane by performing a linear least-square fit. The developed instrument achieved a detection limit of 460 ppm, 141 ppm, 175 ppm and 173 ppm for methane, butane, ethane, and propane, respectively, with a measurement time of 1 second and a cavity length of 0.59 m. These detection limits are less than 1% of the Lower Explosive Limit (LEL) for each gas. The sensitivity can be further enhanced by changing the experimental parameters (such as cavity length, lamp power etc.) and using longer averaging intervals. The detection system is a low-cost and portable instrument suitable for performing field monitorings. The results obtained on the gas mixture emphasize the instrument's potential for deployment at industrial facilities dealing with natural gas, where potential leaks pose a threat to public safety.

  10. Radioactive gas storage device

    International Nuclear Information System (INIS)

    Sano, Yuji.

    1988-01-01

    Purpose: To easily and reliably detect the consumption of a sputtered cathode in a radioactive gas storage device using ion injection method. Constitution: Inert gases are sealed to the inside of a cathode. As the device is operated, the cathode is consumed and, if it is scraped to some extent, inert gases in the cathode gases are blown out to increase the inner pressure of the device. The pressure elevation is detected by a pressure detector connected with a gas introduction pipe or discharge pipe. Further, since the discharge current in the inside is increased along with the elevation of the pressure, it is possible to detect the increase of the electrical current. In this way, the consumption of the cathode can be recognized by detecting the elevation in the pressure or increase in the current. (Ikeda, J.)

  11. Waste heat recovery system including a mechanism for collection, detection and removal of non-condensable gas

    Science.gov (United States)

    Ernst, Timothy C.; Zigan, James A.

    2017-06-20

    The disclosure describes a non-condensable gas collection, detection, and removal system for a WHR system that helps to maintain cycle efficiency of the WHR system across the life of an engine system associated with the WHR system. A storage volume is configured to collect non-condensable gas received from the working fluid circuit, and a release valve is configured to selectively release non-condensable gas contained within the storage volume.

  12. Fracture detection, mapping, and analysis of naturally fractured gas reservoirs using seismic technology. Final report, November 1995

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-10-01

    Many basins in the Rocky Mountains contain naturally fractured gas reservoirs. Production from these reservoirs is controlled primarily by the shape, orientation and concentration of the natural fractures. The detection of gas filled fractures prior to drilling can, therefore, greatly benefit the field development of the reservoirs. The objective of this project was to test and verify specific seismic methods to detect and characterize fractures in a naturally fractured reservoir. The Upper Green River tight gas reservoir in the Uinta Basin, Northeast Utah was chosen for the project as a suitable reservoir to test the seismic technologies. Knowledge of the structural and stratigraphic geologic setting, the fracture azimuths, and estimates of the local in-situ stress field, were used to guide the acquisition and processing of approximately ten miles of nine-component seismic reflection data and a nine-component Vertical Seismic Profile (VSP). Three sources (compressional P-wave, inline shear S-wave, and cross-line, shear S-wave) were each recorded by 3-component (3C) geophones, to yield a nine-component data set. Evidence of fractures from cores, borehole image logs, outcrop studies, and production data, were integrated with the geophysical data to develop an understanding of how the seismic data relate to the fracture network, individual well production, and ultimately the preferred flow direction in the reservoir. The multi-disciplinary approach employed in this project is viewed as essential to the overall reservoir characterization, due to the interdependency of the above factors.

  13. Tentative detection of warm intervening gas towards PKS 0548-322 with XMM-Newton

    Energy Technology Data Exchange (ETDEWEB)

    Barcons, X.

    2005-03-17

    We present the results of a long ({approx} 93 ksec) XMM-Newton observation of the bright BL-Lac object PKS 0548-322 (z = 0.069). Our Reflection Grating Spectrometer (RGS) spectrum shows a single absorption feature at an observed wavelength {lambda} = 23.33 {+-} 0.01 {angstrom} which we interpret as OVI K{alpha} absorption at z = 0.058, i.e., {approx} 3000 km s{sup -1} from the background object. The observed equivalent width of the absorption line {approx} 30m {angstrom}, coupled with the lack of the corresponding absorption edge in the EPIC pn data, implies a column density N{sub OVI} {approx} 2 x 10{sup 16} cm{sup -2} and turbulence with a Doppler velocity parameter b > 100 km s{sup -1}. Within the limitations of our RGS spectrum, no OVII or OV K{alpha} absorption are detected. Under the assumption of ionization equilibrium by both collisions and the extragalactic background, this is only marginally consistent if the gas temperature is {approx} 2.5 x 10{sup 5} K, with significantly lower or higher values being excluded by our limits on OV or OVII. If confirmed, this would be the first X-ray detection of a large amount of intervening warm absorbing gas through OVI absorption. The existence of such a high column density absorber, much stronger than any previously detected one in OVI, would place stringent constraints on the large-scale distribution of baryonic gas in the Universe.

  14. GMDD: a database of GMO detection methods.

    Science.gov (United States)

    Dong, Wei; Yang, Litao; Shen, Kailin; Kim, Banghyun; Kleter, Gijs A; Marvin, Hans J P; Guo, Rong; Liang, Wanqi; Zhang, Dabing

    2008-06-04

    Since more than one hundred events of genetically modified organisms (GMOs) have been developed and approved for commercialization in global area, the GMO analysis methods are essential for the enforcement of GMO labelling regulations. Protein and nucleic acid-based detection techniques have been developed and utilized for GMOs identification and quantification. However, the information for harmonization and standardization of GMO analysis methods at global level is needed. GMO Detection method Database (GMDD) has collected almost all the previous developed and reported GMOs detection methods, which have been grouped by different strategies (screen-, gene-, construct-, and event-specific), and also provide a user-friendly search service of the detection methods by GMO event name, exogenous gene, or protein information, etc. In this database, users can obtain the sequences of exogenous integration, which will facilitate PCR primers and probes design. Also the information on endogenous genes, certified reference materials, reference molecules, and the validation status of developed methods is included in this database. Furthermore, registered users can also submit new detection methods and sequences to this database, and the newly submitted information will be released soon after being checked. GMDD contains comprehensive information of GMO detection methods. The database will make the GMOs analysis much easier.

  15. Simulations of Micro Gas Flows by the DS-BGK Method

    KAUST Repository

    Li, Jun

    2011-01-01

    For gas flows in micro devices, the molecular mean free path is of the same order as the characteristic scale making the Navier-Stokes equation invalid. Recently, some micro gas flows are simulated by the DS-BGK method, which is convergent

  16. Method for eliminating gas blocking in electrokinetic pumping systems

    Science.gov (United States)

    Arnold, Don W.; Paul, Phillip H.; Schoeniger, Joseph S.

    2001-09-11

    A method for eliminating gas bubble blockage of current flow during operation of an electrokinetic pump. By making use of the ability to modify the surface charge on the porous dielectric medium used in electrokinetic pumps, it becomes possible to place electrodes away from the pressurized region of the electrokinetic pump. While gas is still generated at the electrodes they are situated such that the generated gas can escape into a larger buffer reservoir and not into the high pressure region of the pump where the gas bubbles can interrupt current flow. Various combinations of porous dielectric materials and ionic conductors can be used to create pumps that have desirable electrical, material handling, and flow attributes.

  17. Innovation of fission gas release and thermal conductivity measurement methods

    International Nuclear Information System (INIS)

    Van der Meer, K.; Soboler, V.

    1998-01-01

    This presentation described two innovative measurement methods being currently developed at SCK-CEN in order to support the modeling of fuel performance. The first one is an acoustic method to measure the fission gas release in a fuel rod in a non destructive way. The total rod pressure is determined by generating a heat pulse causing a pressure wave that propagates through the gas to an ultrasound transducer. The final pulse width being proportional to the pressure, the latter can thus be determined. The measurement of the acoustic resonance frequency at fixed temperatures enables the distinction between different gas components. The second method is a non-stationary technique to investigate the thermal properties of the fuel rod, like thermal conductivity, diffusivity and heat capacity. These properties are derived from the amplitude and the phase shift of the fuel centre temperature response induced by a periodic temperature variation. These methods did not reveal any physical limitations for the practical applicability. Furthermore, they are rather simple. Preliminary investigations have proven both methods to be more accurate than techniques usually utilized. (author)

  18. Dual-gas tracers for subsurface characterization and NAPL detection

    International Nuclear Information System (INIS)

    Gauglitz, P.A.; Peurrung, L.M.; Mendoza, D.P.; Pillay, G.

    1994-11-01

    Effective design of in situ remediation technologies often requires an understanding of the mass transfer limitations that control the removal of contaminants from the soil. In addition, the presence of nonaqueous phase liquids (NAPLs) in soils will affect the ultimate success or failure of remediation processes. Knowing the location of NAPLs within the subsurface is critical to designing the most effective remediation approach. This work focuses on demonstrating that gas tracers can detect the location of the NAPLs in the subsurface and elucidating the mass transfer limitations associated with the removal of contaminants from soils

  19. Acousto-Optic Q-Switched Fiber Laser-Based Intra-Cavity Photoacoustic Spectroscopy for Trace Gas Detection

    Directory of Open Access Journals (Sweden)

    Qinduan Zhang

    2017-12-01

    Full Text Available We proposed a new method for gas detection in photoacoustic spectroscopy based on acousto-optic Q-switched fiber laser by merging a transmission PAS cell (resonant frequency f0 = 5.3 kHz inside the fiber laser cavity. The Q-switching was achieved by an acousto-optic modulator, achieving a peak pulse power of ~679 mW in the case of the acousto-optic modulation signal with an optimized duty ratio of 10%. We used a custom-made fiber Bragg grating with a central wavelength of 1530.37 nm (the absorption peak of C2H2 to select the laser wavelength. The system achieved a linear response (R2 = 0.9941 in a concentration range from 400 to 7000 ppmv, and the minimum detection limit compared to that of a conventional intensity modulation system was enhanced by 94.2 times.

  20. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory : determination of organophosphate pesticides in bottom sediment by gas chromatography with flame photometric detection

    Science.gov (United States)

    Jha, Virendra Kumar; Wydoski, Duane S.

    2003-01-01

    A method for the isolation of 20 parent organophosphate pesticides and 5 pesticide degradates from bottom-sediment samples is described. The compound O-ethyl-O-methyl-S-proplyphosphorothioate is reported as an estimated concentration because of variable performance. In this method, the sediment samples are centrifuged to remove excess waster mixed with anhydrous sodium sulfate and Soxhlet extracted overnight with dichloromethane (93 percent) and methanol (7 percent). The extract is concentrated and then filtered through a 0.2-micrometer polytetrafluoroethylene membrane syringe filter. An aliquot of the sample extract is quantitatively injected onto two polystyrene-divinylbenzene gel-permeation chromatographic columns connected in series. The compounds are eluted with dichloromethane and a fraction is collected for analysis, with some coextracted interferences, including elemental sulfur, separated and discarded. The aliquot is concentrated and solvent exchanged to ethyl acetate. The extract is analyzed by dual capillary-column gas chromatography with flame photometric detection. Single-operator method detection limits in sodium sulfate matrix samples ranged from 0.81 to 2 micrograms per kilogram. Method performance was validated by spiking all compounds into three different solid matrices (sodium sulfate, bed sediment from Clear Creek, and bed sediment from Evergreen Lake) at three different concentrations. Eight replicates were analyzed at each concentration in each matrix. Mean recoveries of method compounds spiked in Clear Creek samples ranged from 43 to 110 percent, and those in Evergreen Lake samples ranged from 62 to 118 percent for all pesticides. Mean recoveries of method compounds spiked in reagent sodium sulfate samples ranged from 41 to 101 percent for all pesticides. The only exception was O-ethyl-O-methyl-S-propylphosphorothioate, which had an average recovery of 35 percent, and, thus, sample concentration is reported as estimated ('E' remark code).

  1. Development Optimization and Uncertainty Analysis Methods for Oil and Gas Reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Ettehadtavakkol, Amin, E-mail: amin.ettehadtavakkol@ttu.edu [Texas Tech University (United States); Jablonowski, Christopher [Shell Exploration and Production Company (United States); Lake, Larry [University of Texas at Austin (United States)

    2017-04-15

    Uncertainty complicates the development optimization of oil and gas exploration and production projects, but methods have been devised to analyze uncertainty and its impact on optimal decision-making. This paper compares two methods for development optimization and uncertainty analysis: Monte Carlo (MC) simulation and stochastic programming. Two example problems for a gas field development and an oilfield development are solved and discussed to elaborate the advantages and disadvantages of each method. Development optimization involves decisions regarding the configuration of initial capital investment and subsequent operational decisions. Uncertainty analysis involves the quantification of the impact of uncertain parameters on the optimum design concept. The gas field development problem is designed to highlight the differences in the implementation of the two methods and to show that both methods yield the exact same optimum design. The results show that both MC optimization and stochastic programming provide unique benefits, and that the choice of method depends on the goal of the analysis. While the MC method generates more useful information, along with the optimum design configuration, the stochastic programming method is more computationally efficient in determining the optimal solution. Reservoirs comprise multiple compartments and layers with multiphase flow of oil, water, and gas. We present a workflow for development optimization under uncertainty for these reservoirs, and solve an example on the design optimization of a multicompartment, multilayer oilfield development.

  2. Development Optimization and Uncertainty Analysis Methods for Oil and Gas Reservoirs

    International Nuclear Information System (INIS)

    Ettehadtavakkol, Amin; Jablonowski, Christopher; Lake, Larry

    2017-01-01

    Uncertainty complicates the development optimization of oil and gas exploration and production projects, but methods have been devised to analyze uncertainty and its impact on optimal decision-making. This paper compares two methods for development optimization and uncertainty analysis: Monte Carlo (MC) simulation and stochastic programming. Two example problems for a gas field development and an oilfield development are solved and discussed to elaborate the advantages and disadvantages of each method. Development optimization involves decisions regarding the configuration of initial capital investment and subsequent operational decisions. Uncertainty analysis involves the quantification of the impact of uncertain parameters on the optimum design concept. The gas field development problem is designed to highlight the differences in the implementation of the two methods and to show that both methods yield the exact same optimum design. The results show that both MC optimization and stochastic programming provide unique benefits, and that the choice of method depends on the goal of the analysis. While the MC method generates more useful information, along with the optimum design configuration, the stochastic programming method is more computationally efficient in determining the optimal solution. Reservoirs comprise multiple compartments and layers with multiphase flow of oil, water, and gas. We present a workflow for development optimization under uncertainty for these reservoirs, and solve an example on the design optimization of a multicompartment, multilayer oilfield development.

  3. Detection of butane gas inhalation at 16days after hypoxic encephalopathy: A case report.

    Science.gov (United States)

    Sato, Takako; Nishioka, Hiroshi; Tsuboi, Kento; Katagi, Munehiro; Miki, Akihiro; Saito, Takashi; Abe, Shuntaro; Nomura, Masakatsu; Kitagawa, Misa; Tsuchihashi, Hitoshi; Suzuki, Koichi

    2017-11-01

    In Japan, there are increasing reports of death by poisoning following butane abuse. To determine the specific cause of death in such cases, it is important to confirm the presence of fuel gas components in the body, although careful analysis is required because of their volatile properties. In most reported cases, the subject died suddenly during or immediately after butane aspiration. Thus, the butane concentration in the samples from the deceased should be relatively high. Herein, we present a case of an 18-year-old man found with cardiopulmonary arrest, who then exhibited hypoxic encephalopathy for 16days in a hospital. At autopsy, we detected hypoxic encephalopathy, pneumonia, and ischemia-reperfusion injury of the myocardium, while the cause of cardiac arrest remained unclear. Toxicological analysis was then performed for fuel gas components in several specimens collected at autopsy. Results showed that n-butane and isobutane were detected in the adipose tissue at 16days after inhalation, indicating a role of butane gas inhalation as the cause of death. These data suggest that adipose tissue may be the most appropriate analysis sample to be collected at postmortem in cases where involvement of volatile and fat-soluble gas inhalation is suspected. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Application of multivariable analysis methods to the quantitative detection of gas by tin dioxide micro-sensors; Application des methodes d'analyse multivariables a la detection quantitative de gaz par microcapteurs a base de dioxyde d'etain

    Energy Technology Data Exchange (ETDEWEB)

    Perdreau, N.

    2000-01-17

    The electric conductivity of tin dioxide depends on the temperature of the material and on the nature and environment of the surrounding gas. This work shows that the treatment by multivariable analysis methods of electric conductance signals of one sensor allows to determine concentrations of binary or ternary mixtures of ethanol (0-80 ppm), carbon monoxide (0-300 ppm) and methane (0-1000 ppm). A part of this study has consisted of the design and the implementation of an automatic testing bench allowing to acquire the electric conductance of four sensors in thermal cycle and under gaseous cycles. It has also revealed some disturbing effects (humidity,..) of the measurement. Two techniques of sensor fabrication have been used to obtain conductances (depending of temperature) distinct for each gas, reproducible for the different sensors and enough stable with time to allow the exploitation of the signals by multivariable analysis methods (tin dioxide under the form of thin layers obtained by reactive evaporation or under the form of sintered powder bars). In a last part, it has been shown that the quantitative determination of gas by the application of chemo-metry methods is possible although the relation between the electric conductances in one part and the temperatures and concentrations in another part is non linear. Moreover, the modelling with the 'Partial Least Square' method and a pretreatment allows to obtain performance data comparable to those obtained with neural networks. (O.M.)

  5. System and method for producing substitute natural gas from coal

    Science.gov (United States)

    Hobbs, Raymond [Avondale, AZ

    2012-08-07

    The present invention provides a system and method for producing substitute natural gas and electricity, while mitigating production of any greenhouse gasses. The system includes a hydrogasification reactor, to form a gas stream including natural gas and a char stream, and an oxygen burner to combust the char material to form carbon oxides. The system also includes an algae farm to convert the carbon oxides to hydrocarbon material and oxygen.

  6. A new fault detection method for computer networks

    International Nuclear Information System (INIS)

    Lu, Lu; Xu, Zhengguo; Wang, Wenhai; Sun, Youxian

    2013-01-01

    Over the past few years, fault detection for computer networks has attracted extensive attentions for its importance in network management. Most existing fault detection methods are based on active probing techniques which can detect the occurrence of faults fast and precisely. But these methods suffer from the limitation of traffic overhead, especially in large scale networks. To relieve traffic overhead induced by active probing based methods, a new fault detection method, whose key is to divide the detection process into multiple stages, is proposed in this paper. During each stage, only a small region of the network is detected by using a small set of probes. Meanwhile, it also ensures that the entire network can be covered after multiple detection stages. This method can guarantee that the traffic used by probes during each detection stage is small sufficiently so that the network can operate without severe disturbance from probes. Several simulation results verify the effectiveness of the proposed method

  7. New method for 3-dimensional visualization of distributed gas using laser ultrasonic technique; Laser choonpaho ni yoru gas no 3 jigen kukan bunpu keisoku

    Energy Technology Data Exchange (ETDEWEB)

    Ochiai, M.; Kubo, K.; Kanemoto, S. [Toshiba Corp., Tokyo (Japan); Kokubo, T. [Tokyo Electric Power Co., Inc. (Japan)

    1998-11-30

    In case that detection of gas leak is performed applying gas sensors, not only sensing for extremely small amount of gas but also measurement of spatial distribution state from the viewpoint of identification of leaking places are important. Meanwhile, it is known that the methane, main component in fuel gas, has characters which absorbs ray having certain specific wavelength and in addition emits its absorbed energy acoustically. As to a photo-acoustic effect in an open space, it is newly found that the signal has a frequency of about 40 kHz and a propagation directivity which is perpendicular to the laser axis. In the feasibility test based on this property, methane molecules are excited by an optical parametric oscillator (OPO) type laser source which has a wavelength of 1330 micron and an output power of about 5 mJ/pulse. Array microphones and 2-dimensional laser scanning system are used for detecting the gas distribution. In the next place, owing to analyzing phase differences of sound wave on the basis of oscillation time of pulse laser, it was verified that the 3-dimensional distribution of gas was measurable. 8 refs., 9 figs., 2 tabs.

  8. Experimental substantiation of combined methods for designing processes for the commercial preparation of gas at gas condensate fields

    Energy Technology Data Exchange (ETDEWEB)

    Gurevich, G R; Karlinskii, E D; Posypkina, T V

    1977-04-01

    An analysis is made of the possibility of using two analytical methods for studying vapor--liquid equilibrium of hydrocarbon mixtures that are used in designing the separation of natural gas and the stabilization of condensate--the Chao and Sider method, which uses computations by equilibrium constants. A combined computational method is proposed for describing a unified process of natural gas separation and condensate stabilization. The method of preparing the original data for the computation of the separation and stabilization processes can be significantly simplified. 10 references, 1 table.

  9. A case study to optimum selection of deliquification method for gas condensate well design: South Pars gas field

    Directory of Open Access Journals (Sweden)

    Ehsan Khamehchi

    2016-06-01

    Today, the most effective liquid-removal devices are pumping, the combination of liquid-diverter with gas lift and velocity string. Considering mentioned complexities, the most efficient method of liquid removal is different from one well to the others. This paper discusses a multi-criteria decision making (MCDM strategy for ranking these methods based on ELECTRE and TOPSIS techniques in a gas condensate reservoir. The most efficient model in this case, regarding its high efficiency and level of reliability is continuous gas lift. These procedures can be extended to other cases easily by changing the comparison matrix and user defined weights.

  10. Detection of radiation-induced hydrocarbons in Camembert irradiated before and after the maturing process-comparison of florisil column chromatography and on-line coupled liquid chromatography-gas chromatography

    International Nuclear Information System (INIS)

    Schulzki, G.; Spiegelberg, A.; Bögl, K.W.; Schreiber, G.A.

    1995-01-01

    The influence of the maturing process on the detection of radiation-induced volatile hydrocarbons in the fat of Camembert has been investigated. Two analytical methods for separation of the hydrocarbon fraction from the lipid were applied: Florisil column chromatography with subsequent gas chromatographic-mass spectrometric (GC-MS) determination as well as on-line coupled liquid chromatography-GC-MS. The maturing process had no influence on the detection of radiation-induced volatiles. Comparable results were achieved with both analytical methods. However, preference is given to the more effective on-line coupled LC-GC method

  11. Development of a simple and sensitive method for the characterization of odorous waste gas emissions by means of solid-phase microextraction (SPME) and GC-MS/olfactometry.

    Science.gov (United States)

    Kleeberg, K K; Liu, Y; Jans, M; Schlegelmilch, M; Streese, J; Stegmann, R

    2005-01-01

    A solid-phase microextraction (SPME) method has been developed for the extraction of odorous compounds from waste gas. The enriched compounds were characterized by gas chromatography-mass spectrometry (GC-MS) and gas chromatography followed by simultaneous flame ionization detection and olfactometry (GC-FID/O). Five different SPME fiber coatings were tested, and the carboxen/polydimethylsiloxane (CAR/PDMS) fiber showed the highest ability to extract odorous compounds from the waste gas. Furthermore, parameters such as exposure time, desorption temperature, and desorption time have been optimized. The SPME method was successfully used to characterize an odorous waste gas from a fat refinery prior to and after waste gas treatment in order to describe the treatment efficiency of the used laboratory scale plant which consisted of a bioscrubber/biofilter combination and an activated carbon adsorber. The developed method is a valuable approach to provide detailed information of waste gas composition and complements existing methods for the determination of odors. However, caution should be exercised if CAR/PDMS fibers are used for the quantification of odorous compounds in multi-component matrices like waste gas emissions since the relative affinity of each analyte was shown to differ according to the total amount of analytes present in the sample.

  12. METHODS FOR ORGANIZATION OF WORKING PROCESS FOR GAS-DIESEL ENGINE

    Directory of Open Access Journals (Sweden)

    G. A. Vershina

    2017-01-01

    Full Text Available Over the past few decades reduction in pollutant emissions has become one of the main directions for further deve- lopment of engine technology. Solution of such problems has led to implementation of catalytic post-treatment systems, new technologies of fuel injection, technology for regulated phases of gas distribution, regulated turbocharger system and, lately, even system for variable compression ratio of engine. Usage of gaseous fuel, in particular gas-diesel process, may be one of the means to reduce air pollution caused by toxic substances and meet growing environmental standards and regulations. In this regard, an analysis of methods for organization of working process for a gas-diesel engine has been conducted in the paper. The paper describes parameters that influence on the nature of gas diesel process, it contains graphics of specific total heat consumption according to ignition portion of diesel fuel and dependence of gas-diesel indices on advance angle for igni-tion portion injection of the diesel fuel. A modern fuel system of gas-diesel engine ГД-243 has been demonstrated in the pa- per. The gas-diesel engine has better environmental characteristics than engines running on diesel fuel or gasoline. According to the European Natural & bio Gas Vehicle Association a significant reduction in emissions is reached at a 50%-substitution level of diesel fuel by gas fuel (methane and in such a case there is a tendency towards even significant emission decrease. In order to ensure widespread application of gaseous fuel as fuel for gas-diesel process it is necessary to develop a new wor- king process, to improve fuel equipment, to enhance injection strategy and fuel supply control. A method for organization of working process for multi-fuel engine has been proposed on the basis of the performed analysis. An application has been submitted for a patent.

  13. Method for the removal of elemental mercury from a gas stream

    Science.gov (United States)

    Mendelsohn, Marshall H.; Huang, Hann-Sheng

    1999-01-01

    A method is provided to remove elemental mercury from a gas stream by reacting the gas stream with an oxidizing solution to convert the elemental mercury to soluble mercury compounds. Other constituents are also oxidized. The gas stream is then passed through a wet scrubber to remove the mercuric compounds and oxidized constituents.

  14. Gas jet studies towards an optimization of the IGISOL LIST method

    CERN Document Server

    Reponen, M; Kurpeta, J; Sonnenschein, V; Pohjalainen, I; Aysto, J; Kessler, T; Piszczek, S; Karvonen, P; Marsh, B

    2011-01-01

    Gas jets emitted from an ion guide have been studied as a function of nozzle type and gas cell-to-background pressure ratio in order to obtain a low divergent, uniform jet over a distance of several cm. The jet has been probed by imaging the light emitted from excited argon or helium gas atoms. For a simple exit hole or converging-diverging nozzle, the jet diameter was found to be insensitive to the nozzle shape and inlet pressure. Sonic jets with a FWHM below 6 mm were achieved with a background pressure larger than 1 mbar in the expansion chamber. The measurements are supported by the detection of radioactive (219)Rn recoils from an alpha recoil source mounted within the gas cell. A Laval nozzle produced a well-collimated supersonic jet at low background pressures with a FWHM of similar to 6 mm over a distance of 14 cm. Direct Pitot probe measurements, on-axis, revealed a non-uniform pressure distribution in the gas jet of the Laval nozzle, supporting the visual observations. All measurements are motivated ...

  15. Gas phase collision dynamics by means of pulse-radiolysis methods

    International Nuclear Information System (INIS)

    Hatano, Yoshihiko

    1989-01-01

    After a brief survey of recent advances in gas-phase collision dynamics studies using pulse radiolysis methods, the following two topics in our research programs are presented with emphasis on the superior advantages of the pulse radiolysis methods over the various methods of gas-phase collision dynamics, such as beam methods, swarm methods and flow methods. One of the topics is electron attachment to van der Waals molecules. The attachment rates of thermal electrons to O 2 and other molecules in dense gases have been measured in wide ranges of both gas temperatures and pressures, from which experimental evidence has been obtained for electron attachment to van der Waals molecules. The results have been compared with theories and discussed in terms of the effect of van der Waals interaction on the electron attachment resonance. The obtained conclusions have been related with investigations of electron attachment, solvation and localization in the condensed phase. The other is Penning ionization and its related processes. The rate constants for the de-excitation of He(2 1 P), He(2 3 S), Ne( 3 P 0 ), Ne( 3 P 1 ), Ne( 3 P 2 ), Ar( 1 P 1 ), Ar( 3 P 1 ), by atoms and molecules have been measured in the temperature range from 100 to 300 K, thus obtaining the collisional energy dependence of the de-excitation cross sections. The results are compared in detail with theories classified according to the excited rare gas atoms in the metastable and resonance states. (author)

  16. Methods of Si based ceramic components volatilization control in a gas turbine engine

    Science.gov (United States)

    Garcia-Crespo, Andres Jose; Delvaux, John; Dion Ouellet, Noemie

    2016-09-06

    A method of controlling volatilization of silicon based components in a gas turbine engine includes measuring, estimating and/or predicting a variable related to operation of the gas turbine engine; correlating the variable to determine an amount of silicon to control volatilization of the silicon based components in the gas turbine engine; and injecting silicon into the gas turbine engine to control volatilization of the silicon based components. A gas turbine with a compressor, combustion system, turbine section and silicon injection system may be controlled by a controller that implements the control method.

  17. On-line purge-and-trap-gas chromatography with flame ionization detection as an alternative analytical method for dimethyl sulphide trace release from marine algae

    Energy Technology Data Exchange (ETDEWEB)

    Careri, M.; Musci, M.; Bianchi, F.; Mucchino, C. [Parma Univ., Parma (Italy). Dipt. di Chimica Generale ed Inorganica, Chimica Analitica e Chimica Fisica; Azzoni, R.; Viaroli, P. [Parma Univ., Parma (Italy). Dipt. di Scienze Ambientali

    2001-10-01

    The release of dimethyl sulphide (DMS) by the seaweed Ulva spp at trace level was studied in aqueous solutions at different salinities, temperature and light intensities. For this purpose, the purge-and-trap technique combined with gas chromatography-flame ionization detection was used. The analytical method was evaluated in terms of linearity range, limit of detection, precision and accuracy by considering 10% (w/v) and 30% (w/v) synthetic seawater as aqueous matrices. Calculation of the recovery function evidenced a matrix influence. The method of standard addition was then used for an accurate determination of DMS in synthetic seawater reproduction the matrix effect. DMS fluxes were analysed in batch cultures of Ulva spp reproducing the conditions which usually occur in the Sacca di Goro lagoon (Northern Adriatic Sea, Italy). [Italian] Il rilascio di dimetilsolfuro (DMS) in tracce da parte della macroalga Ulva spp e' stato studiato in soluzioni acquose di differente salinita' mediante la tecnica purge-and-trap accoppiata on-line alla gascromatografia con rivelazione a ionizzazione di fiamma (GC-FID). Il metodo analitico e' stato validato in termini di linearita' di risposta, di limite di rivelabilita', precisione e accuratezza considerando come matrice acqua di mare sintetica a diversa salinita' (10%0 m/v e 30%0 m/v). Il calcolo della funzione di recupero ha consentito di verificare la presenza di errori sistematici dovuti all'effetto matrice. Il metodo sviluppato e' stato quindi applicato a matrici ambientali allo scopo di verificare il rilascio di DMS da parte di Ulva spp, operando in condizioni ambientali simili a quelle che si verificano nella Sacca di Goro (Ferrara, Italia).

  18. Fission signal detection using helium-4 gas fast neutron scintillation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, J. M., E-mail: lewisj@ufl.edu; Kelley, R. P.; Jordan, K. A. [Nuclear Engineering Program, University of Florida, Gainesville, Florida 32611 (United States); Murer, D. [Arktis Radiation Detectors Ltd., 8045 Zurich (Switzerland)

    2014-07-07

    We demonstrate the unambiguous detection of the fission neutron signal produced in natural uranium during active neutron interrogation using a deuterium-deuterium fusion neutron generator and a high pressure {sup 4}He gas fast neutron scintillation detector. The energy deposition by individual neutrons is quantified, and energy discrimination is used to differentiate the induced fission neutrons from the mono-energetic interrogation neutrons. The detector can discriminate between different incident neutron energies using pulse height discrimination of the slow scintillation component of the elastic scattering interaction between a neutron and the {sup 4}He atom. Energy histograms resulting from this data show the buildup of a detected fission neutron signal at higher energies. The detector is shown here to detect a unique fission neutron signal from a natural uranium sample during active interrogation with a (d, d) neutron generator. This signal path has a direct application to the detection of shielded nuclear material in cargo and air containers. It allows for continuous interrogation and detection while greatly minimizing the potential for false alarms.

  19. Multi-spectral temperature measurement method for gas turbine blade

    Science.gov (United States)

    Gao, Shan; Feng, Chi; Wang, Lixin; Li, Dong

    2016-02-01

    One of the basic methods to improve both the thermal efficiency and power output of a gas turbine is to increase the firing temperature. However, gas turbine blades are easily damaged in harsh high-temperature and high-pressure environments. Therefore, ensuring that the blade temperature remains within the design limits is very important. There are unsolved problems in blade temperature measurement, relating to the emissivity of the blade surface, influences of the combustion gases, and reflections of radiant energy from the surroundings. In this study, the emissivity of blade surfaces has been measured, with errors reduced by a fitting method, influences of the combustion gases have been calculated for different operational conditions, and a reflection model has been built. An iterative computing method is proposed for calculating blade temperatures, and the experimental results show that this method has high precision.

  20. Method for selective detection of explosives in mass spectrometer or ion mobility spectrometer at parts-per-quadrillion level

    Science.gov (United States)

    Ewing, Robert G.; Atkinson, David A.; Clowers, Brian H.

    2015-09-01

    A method for selective detection of volatile and non-volatile explosives in a mass spectrometer or ion mobility spectrometer at a parts-per-quadrillion level without preconcentration is disclosed. The method comprises the steps of ionizing a carrier gas with an ionization source to form reactant ions or reactant adduct ions comprising nitrate ions (NO.sub.3.sup.-); selectively reacting the reactant ions or reactant adduct ions with at least one volatile or non-volatile explosive analyte at a carrier gas pressure of at least about 100 Ton in a reaction region disposed between the ionization source and an ion detector, the reaction region having a length which provides a residence time (tr) for reactant ions therein of at least about 0.10 seconds, wherein the selective reaction yields product ions comprising reactant ions or reactant adduct ions that are selectively bound to the at least one explosive analyte when present therein; and detecting product ions with the ion detector to determine presence or absence of the at least one explosive analyte.

  1. Method for the removal of elemental mercury from a gas stream

    Science.gov (United States)

    Mendelsohn, M.H.; Huang, H.S.

    1999-05-04

    A method is provided to remove elemental mercury from a gas stream by reacting the gas stream with an oxidizing solution to convert the elemental mercury to soluble mercury compounds. Other constituents are also oxidized. The gas stream is then passed through a wet scrubber to remove the mercuric compounds and oxidized constituents. 7 figs.

  2. Development of a Method for Rapid Determination of Morpholine in Juices and Drugs by Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Mengsi Cao

    2018-01-01

    Full Text Available A reliable derivatization method has been developed to detect and quantify morpholine in apple juices and ibuprofen with gas chromatography-mass spectrometry. Morpholine can react with sodium nitrite under acidic condition to produce stable and volatile N-nitrosomorpholine derivative. In this experiment, various factors affecting the derivatization and extraction process were optimized, including volume and concentration of hydrochloric acid, quantity of sodium nitrite, derivatization temperature, derivatization time, extraction reagents, and extraction time. The derivative was extracted with dichloromethane and determined by gas chromatography-mass spectrometry. The linearity range of morpholine was 10–500 μg·L−1 with good correlation, and limits of detection (LOD and limits of quantification (LOQ were 7.3 μg·L−1 and 24.4 μg·L−1, respectively. Low, medium, and high concentrations of morpholine were added in apple juices and ibuprofen samples to evaluate standard recovery rate and relative standard deviation. The spiked recovery rate ranged from 94.3% to 109.0%, and the intraday repeatability and interday reproducibility were 2.0%–4.4% and 3.3%–7.0%, respectively. The developed method has good accuracy and precision. This quantitative method for morpholine is simple, sensitive, rapid, and low cost and can successfully be applied to analyze the residual morpholine in apple juices and drug samples.

  3. A method for measuring the local gas pressure within a gas-flow stage in situ in the transmission electron microscope

    International Nuclear Information System (INIS)

    Colby, R.; Alsem, D.H.; Liyu, A.; Kabius, B.

    2015-01-01

    Environmental transmission electron microscopy (TEM) has enabled in situ experiments in a gaseous environment with high resolution imaging and spectroscopy. Addressing scientific challenges in areas such as catalysis, corrosion, and geochemistry can require pressures much higher than the ∼20 mbar achievable with a differentially pumped environmental TEM. Gas flow stages, in which the environment is contained between two semi-transparent thin membrane windows, have been demonstrated at pressures of several atmospheres. However, the relationship between the pressure at the sample and the pressure drop across the system is not clear for some geometries. We demonstrate a method for measuring the gas pressure at the sample by measuring the ratio of elastic to inelastic scattering and the defocus of the pair of thin windows. This method requires two energy filtered high-resolution TEM images that can be performed during an ongoing experiment, at the region of interest. The approach is demonstrated to measure greater than atmosphere pressures of N 2 gas using a commercially available gas-flow stage. This technique provides a means to ensure reproducible sample pressures between different experiments, and even between very differently designed gas-flow stages. - Highlights: • Method developed for measuring gas pressure within a gas-flow stage in the TEM. • EFTEM and CTF-fitting used to calculate amount and volume of gas. • Requires only a pair of images without leaving region of interest. • Demonstrated for P > 1 atm with a common commercial gas-flow stage

  4. Simulations of Micro Gas Flows by the DS-BGK Method

    KAUST Repository

    Li, Jun

    2011-01-01

    For gas flows in micro devices, the molecular mean free path is of the same order as the characteristic scale making the Navier-Stokes equation invalid. Recently, some micro gas flows are simulated by the DS-BGK method, which is convergent to the BGK equation and very efficient for low-velocity cases. As the molecular reflection on the boundary is the dominant effect compared to the intermolecular collisions in micro gas flows, the more realistic boundary condition, namely the CLL reflection model, is employed in the DS-BGK simulation and the influence of the accommodation coefficients used in the molecular reflection model on the results are discussed. The simulation results are verified by comparison with those of the DSMC method as criteria. Copyright © 2011 by ASME.

  5. A Gas-kinetic Discontinuous Galerkin Method for Viscous Flow Equations

    International Nuclear Information System (INIS)

    Liu, Hongwei; Xu, Kun

    2007-01-01

    This paper presents a Runge-Kutta discontinuous Galerkin (RKDG) method for viscous flow computation. The construction of the RKDG method is based on a gas-kinetic formulation, which not only couples the convective and dissipative terms together, but also includes both discontinuous and continuous representation in the flux evaluation at the cell interface through a simple hybrid gas distribution function. Due to the intrinsic connection between the gaskinetic BGK model and the Navier-Stokes equations, the Navier-Stokes flux is automatically obtained by the present method. Numerical examples for both one dimensional (10) and two dimensional(20) compressible viscous flows are presented to demonstrate the accuracy and shock capturing capability of the current RKDG method

  6. Fuel failure detection device

    International Nuclear Information System (INIS)

    Katagiri, Masaki.

    1979-01-01

    Purpose: To improve the SN ratio in the detection. Constitution: Improved precipitator method is provided. Scintillation detectors of a same function are provided respectively by each one before and after a gas reservoir for depositing fission products in the cover gas to detecting wires. The outputs from the two detectors (output from the wire not deposited with the fission products and the output from the wire after deposition) are compared to eliminate background noises resulted from not-decayed nucleides. A subtraction circuit is provided for the elimination. Since the background noises of the detecting wire can thus be measured and corrected on every detection, the SN ratio can be increased. (Ikeda, J.)

  7. GasBench/isotope ratio mass spectrometry: a carbon isotope approach to detect exogenous CO(2) in sparkling drinks.

    Science.gov (United States)

    Cabañero, Ana I; San-Hipólito, Tamar; Rupérez, Mercedes

    2007-01-01

    A new procedure for the determination of carbon dioxide (CO(2)) (13)C/(12)C isotope ratios, using direct injection into a GasBench/isotope ratio mass spectrometry (GasBench/IRMS) system, has been developed to improve isotopic methods devoted to the study of the authenticity of sparkling drinks. Thirty-nine commercial sparkling drink samples from various origins were analyzed. Values of delta(13)C(cava) ranged from -20.30 per thousand to -23.63 per thousand, when C3 sugar addition was performed for a second alcoholic fermentation. Values of delta(13)C(water) ranged from -5.59 per thousand to -6.87 per thousand in the case of naturally carbonated water or water fortified with gas from the spring, and delta(13)C(water) ranged from -29.36 per thousand to -42.09 per thousand when industrial CO(2) was added. It has been demonstrated that the addition of C4 sugar to semi-sparkling wine (aguja) and industrial CO(2) addition to sparkling wine (cava) or water can be detected. The new procedure has advantages over existing methods in terms of analysis time and sample treatment. In addition, it is the first isotopic method developed that allows (13)C/(12)C determination directly from a liquid sample without previous CO(2) extraction. No significant isotopic fractionation was observed nor any influence by secondary compounds present in the liquid phase. Copyright (c) 2007 John Wiley & Sons, Ltd.

  8. Reasons for the appearance of pulsations in gas-lift wells and methods of eliminating them

    Energy Technology Data Exchange (ETDEWEB)

    Sibirev, A P; Grekhov, V V; Leonov, V A; Shigapov, R R

    1985-01-01

    It is shown that the main reason for pulsation in the gas-lift well output is lack of coordinated operation between the bed and the gas-lift lifter. A plan is suggested for making decisions to conduct work to detect and eliminate pulsations in the gas-lift well output which permit elimination of the pulsation in the shortest time and with the least outlays.

  9. New mathematical method for the solution of gas-gas equilibria with special application to HTGR primary-coolant environments

    International Nuclear Information System (INIS)

    Bongartz, K.

    1983-07-01

    A new mathematical method and corresponding computer program have been developed that provide a general method for the numerical solution of an equilibrium problem involving the chemical interactions of gaseous species. The method and computer code were developed to calculate the equilibrium concentrations of impurity gases, such as CO, CO 2 , H 2 , H 2 O, CH 4 , and O 2 , which may be approached as the result of gaseous chemical reactions occurring within the hot primary coolant helium of a high-temperature gas-cooled reactor (HTGR). The method, however, can be applied to any gas mixture

  10. Study on Method of Ultrasonic Gas Temperature Measure Based on FPGA

    Energy Technology Data Exchange (ETDEWEB)

    Wen, S H; Xu, F R [Institute of Electrical Engineering, Yanshan University, Qinhuangdao, 066004 (China)

    2006-10-15

    It is always a problem to measure instantaneous temperature of high-temperature and high-pressure gas. There is difficulty for the conventional method of measuring temperature to measure quickly and exactly, and the measuring precision is low, the ability of anti-jamming is bad, etc. So the article introduces a method of measuring burning gas temperature using ultrasonic based on Field-Programmable Gate Array (FPGA). The mathematic model of measuring temperature is built with the relation of velocity of ultrasonic transmitting and gas Kelvin in the ideal gas. The temperature can be figured out by measuring the difference of ultrasonic frequency {delta}f. FPGA is introduced and a high-precision data acquisition system based on digital phase-shift technology is designed. The feasibility of proposed above is confirmed more by measuring pressure of burning gas timely. Experimental result demonstrates that the error is less than 12.. and the precision is heightened to 0.8%.

  11. Improvement of mineral oil saturated and aromatic hydrocarbons determination in edible oil by liquid-liquid-gas chromatography with dual detection.

    Science.gov (United States)

    Zoccali, Mariosimone; Barp, Laura; Beccaria, Marco; Sciarrone, Danilo; Purcaro, Giorgia; Mondello, Luigi

    2016-02-01

    Mineral oils, which are mainly composed of saturated hydrocarbons and aromatic hydrocarbons, are widespread food contaminants. Liquid chromatography coupled to gas chromatography with flame ionization detection represents the method of choice to determine these two families. However, despite the high selectivity of this technique, the presence of olefins (particularly squalene and its isomers) in some samples as in olive oils, does not allow the correct quantification of the mineral oil aromatic hydrocarbons fraction, requiring additional off-line tools to eliminate them. In the present research, a novel on-line liquid chromatography coupled to gas chromatography method is described for the determination of hydrocarbon contamination in edible oils. Two different liquid chromatography columns, namely a silica one (to retain the bulk of the matrix) and a silver-ion one (which better retains the olefins), were coupled in series to obtain the mineral oil aromatic hydrocarbons hump free of interfering peaks. Furthermore, the use of a simultaneous dual detection, flame ionization detector and triple quadrupole mass spectrometer allowed us not only to quantify the mineral oil contamination, but also to evaluate the presence of specific markers (i.e. hopanes) to confirm the petrogenic origin of the contamination. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Global mass conservation method for dual-continuum gas reservoir simulation

    KAUST Repository

    Wang, Yi; Sun, Shuyu; Gong, Liang; Yu, Bo

    2018-01-01

    In this paper, we find that the numerical simulation of gas flow in dual-continuum porous media may generate unphysical or non-robust results using regular finite difference method. The reason is the unphysical mass loss caused by the gas compressibility and the non-diagonal dominance of the discretized equations caused by the non-linear well term. The well term contains the product of density and pressure. For oil flow, density is independent of pressure so that the well term is linear. For gas flow, density is related to pressure by the gas law so that the well term is non-linear. To avoid these two problems, numerical methods are proposed using the mass balance relation and the local linearization of the non-linear source term to ensure the global mass conservation and the diagonal dominance of discretized equations in the computation. The proposed numerical methods are successfully applied to dual-continuum gas reservoir simulation. Mass conservation is satisfied while the computation becomes robust. Numerical results show that the location of the production well relative to the large-permeability region is very sensitive to the production efficiency. It decreases apparently when the production well is moved from the large-permeability region to the small-permeability region, even though the well is very close to the interface of the two regions. The production well is suggested to be placed inside the large-permeability region regardless of the specific position.

  13. Global mass conservation method for dual-continuum gas reservoir simulation

    KAUST Repository

    Wang, Yi

    2018-03-17

    In this paper, we find that the numerical simulation of gas flow in dual-continuum porous media may generate unphysical or non-robust results using regular finite difference method. The reason is the unphysical mass loss caused by the gas compressibility and the non-diagonal dominance of the discretized equations caused by the non-linear well term. The well term contains the product of density and pressure. For oil flow, density is independent of pressure so that the well term is linear. For gas flow, density is related to pressure by the gas law so that the well term is non-linear. To avoid these two problems, numerical methods are proposed using the mass balance relation and the local linearization of the non-linear source term to ensure the global mass conservation and the diagonal dominance of discretized equations in the computation. The proposed numerical methods are successfully applied to dual-continuum gas reservoir simulation. Mass conservation is satisfied while the computation becomes robust. Numerical results show that the location of the production well relative to the large-permeability region is very sensitive to the production efficiency. It decreases apparently when the production well is moved from the large-permeability region to the small-permeability region, even though the well is very close to the interface of the two regions. The production well is suggested to be placed inside the large-permeability region regardless of the specific position.

  14. Method of treating final products from flue gas desulfurization

    International Nuclear Information System (INIS)

    Bloss, W.; Mohn, U.

    1984-01-01

    A method of treating final products from a flue gas desulfurization. The flue gas desulfurization is carried out by the absorption of sulfur oxide in a spray dryer with a suspension which contains lime, or in a reactor with a dry, fine-grained, absorbent which contains lime. Prior to desulfurization, the fly ash carried along by the flue gas which is to be desulfurized is separated entirely, partially, or not at all from the flue gas, and the final products from the flue gas desulfurization, prior to any further treatment thereof, amount to 1-99% by weight, preferably 1-70% by weight, of fly ash, and 1-99% by weight, preferably 30-99% by weight, of the sum of the desulfurization products, preferably calcium sulfite hemihydrate, and/or calcium sulfite, and/or calcium sulfate dyhydrate, and/or calcium sulfate hemihydrate, and/or calcium sulfate, as well as residue of the absorbent. The reduction of the amount of calcium sulfite is implemented by a dry oxidation with air

  15. Data-driven fault detection, isolation and estimation of aircraft gas turbine engine actuator and sensors

    Science.gov (United States)

    Naderi, E.; Khorasani, K.

    2018-02-01

    In this work, a data-driven fault detection, isolation, and estimation (FDI&E) methodology is proposed and developed specifically for monitoring the aircraft gas turbine engine actuator and sensors. The proposed FDI&E filters are directly constructed by using only the available system I/O data at each operating point of the engine. The healthy gas turbine engine is stimulated by a sinusoidal input containing a limited number of frequencies. First, the associated system Markov parameters are estimated by using the FFT of the input and output signals to obtain the frequency response of the gas turbine engine. These data are then used for direct design and realization of the fault detection, isolation and estimation filters. Our proposed scheme therefore does not require any a priori knowledge of the system linear model or its number of poles and zeros at each operating point. We have investigated the effects of the size of the frequency response data on the performance of our proposed schemes. We have shown through comprehensive case studies simulations that desirable fault detection, isolation and estimation performance metrics defined in terms of the confusion matrix criterion can be achieved by having access to only the frequency response of the system at only a limited number of frequencies.

  16. Method and apparatus for producing synthesis gas

    Science.gov (United States)

    Hemmings, John William; Bonnell, Leo; Robinson, Earl T.

    2010-03-03

    A method and apparatus for reacting a hydrocarbon containing feed stream by steam methane reforming reactions to form a synthesis gas. The hydrocarbon containing feed is reacted within a reactor having stages in which the final stage from which a synthesis gas is discharged incorporates expensive high temperature materials such as oxide dispersed strengthened metals while upstream stages operate at a lower temperature allowing the use of more conventional high temperature alloys. Each of the reactor stages incorporate reactor elements having one or more separation zones to separate oxygen from an oxygen containing feed to support combustion of a fuel within adjacent combustion zones, thereby to generate heat to support the endothermic steam methane reforming reactions.

  17. Electrochemical and Infrared Absorption Spectroscopy Detection of SF6 Decomposition Products

    Directory of Open Access Journals (Sweden)

    Ming Dong

    2017-11-01

    Full Text Available Sulfur hexafluoride (SF6 gas-insulated electrical equipment is widely used in high-voltage (HV and extra-high-voltage (EHV power systems. Partial discharge (PD and local heating can occur in the electrical equipment because of insulation faults, which results in SF6 decomposition and ultimately generates several types of decomposition products. These SF6 decomposition products can be qualitatively and quantitatively detected with relevant detection methods, and such detection contributes to diagnosing the internal faults and evaluating the security risks of the equipment. At present, multiple detection methods exist for analyzing the SF6 decomposition products, and electrochemical sensing (ES and infrared (IR spectroscopy are well suited for application in online detection. In this study, the combination of ES with IR spectroscopy is used to detect SF6 gas decomposition. First, the characteristics of these two detection methods are studied, and the data analysis matrix is established. Then, a qualitative and quantitative analysis ES-IR model is established by adopting a two-step approach. A SF6 decomposition detector is designed and manufactured by combining an electrochemical sensor and IR spectroscopy technology. The detector is used to detect SF6 gas decomposition and is verified to reliably and accurately detect the gas components and concentrations.

  18. Electrochemical and Infrared Absorption Spectroscopy Detection of SF6 Decomposition Products

    Science.gov (United States)

    Dong, Ming; Ren, Ming; Ye, Rixin

    2017-01-01

    Sulfur hexafluoride (SF6) gas-insulated electrical equipment is widely used in high-voltage (HV) and extra-high-voltage (EHV) power systems. Partial discharge (PD) and local heating can occur in the electrical equipment because of insulation faults, which results in SF6 decomposition and ultimately generates several types of decomposition products. These SF6 decomposition products can be qualitatively and quantitatively detected with relevant detection methods, and such detection contributes to diagnosing the internal faults and evaluating the security risks of the equipment. At present, multiple detection methods exist for analyzing the SF6 decomposition products, and electrochemical sensing (ES) and infrared (IR) spectroscopy are well suited for application in online detection. In this study, the combination of ES with IR spectroscopy is used to detect SF6 gas decomposition. First, the characteristics of these two detection methods are studied, and the data analysis matrix is established. Then, a qualitative and quantitative analysis ES-IR model is established by adopting a two-step approach. A SF6 decomposition detector is designed and manufactured by combining an electrochemical sensor and IR spectroscopy technology. The detector is used to detect SF6 gas decomposition and is verified to reliably and accurately detect the gas components and concentrations. PMID:29140268

  19. Sensitivity of Particle Size in Discrete Element Method to Particle Gas Method (DEM_PGM) Coupling in Underbody Blast Simulations

    Science.gov (United States)

    2016-06-12

    Particle Size in Discrete Element Method to Particle Gas Method (DEM_PGM) Coupling in Underbody Blast Simulations Venkatesh Babu, Kumar Kulkarni, Sanjay...buried in soil viz., (1) coupled discrete element & particle gas methods (DEM-PGM) and (2) Arbitrary Lagrangian-Eulerian (ALE), are investigated. The...DEM_PGM and identify the limitations/strengths compared to the ALE method. Discrete Element Method (DEM) can model individual particle directly, and

  20. Gas theft: Prevention and detection

    International Nuclear Information System (INIS)

    Johnson, G.

    1992-01-01

    The problem of gas theft is discussed. Roughly 2% of gas and power customers in the United States either steal or attempt to steal service. Most diversion programs focus on theft from a revenue protection viewpoint, however there is often insufficient money recovered to justify an anti-theft program. Successful action often involves focusing on large volume users. Safety should be a prime consideration in searching out gas theft, as many people have been killed or injured as a result of careless theft. A brief review is presented of anti-theft devices such as locks and seals; automated meter reading can also help reduce theft. The best defence against theft is a highly trained and motivated field staff, especially meter readers, and a computer billing program that monitors changes in gas usage. Fixed bypasses may be unlocked and used at will; fraud is also common. Investigation and prosecution should be carried out by trained personnel following a carefully developed procedure. Safety issues should be stressed, and every effort should be made to avoid the appearance that the justice system is being used as a bill collector. 3 refs

  1. Aircraft Engine Gas Path Diagnostic Methods: Public Benchmarking Results

    Science.gov (United States)

    Simon, Donald L.; Borguet, Sebastien; Leonard, Olivier; Zhang, Xiaodong (Frank)

    2013-01-01

    Recent technology reviews have identified the need for objective assessments of aircraft engine health management (EHM) technologies. To help address this issue, a gas path diagnostic benchmark problem has been created and made publicly available. This software tool, referred to as the Propulsion Diagnostic Method Evaluation Strategy (ProDiMES), has been constructed based on feedback provided by the aircraft EHM community. It provides a standard benchmark problem enabling users to develop, evaluate and compare diagnostic methods. This paper will present an overview of ProDiMES along with a description of four gas path diagnostic methods developed and applied to the problem. These methods, which include analytical and empirical diagnostic techniques, will be described and associated blind-test-case metric results will be presented and compared. Lessons learned along with recommendations for improving the public benchmarking processes will also be presented and discussed.

  2. Flammable gas safety program. Analytical methods development: FY 1993 progress report

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, J.A.; Clauss, S.; Grant, K.; Hoopes, V.; Lerner, B.; Lucke, R.; Mong, G.; Rau, J.; Steele, R.

    1994-01-01

    This report describes the status of developing analytical methods to account for the organic constituents in Hanford waste tanks, with particular emphasis on those tanks that have been assigned to the Flammable Gas Watch List. Six samples of core segments from Tank 101-SY, obtained during the window E core sampling, have been analyzed for organic constituents. Four of the samples were from the upper region, or convective layer, of the tank and two were from the lower, nonconvective layer. The samples were analyzed for chelators, chelator fragments, and several carboxylic acids by derivatization gas chromatography/mass spectrometry (GC/MS). The major components detected were ethylenediaminetetraacetic acid (EDTA), nitroso-iminodiacetic acid (NIDA), nitrilotriacetic acid (NTA), citric acid (CA), succinic acid (SA), and ethylenediaminetriacetic acid (ED3A). The chelator of highest concentration was EDTA in all six samples analyzed. Liquid chromatography (LC) was used to quantitate low molecular weight acids (LMWA) including oxalic, formic, glycolic, and acetic acids, which are present in the waste as acid salts. From 23 to 61% of the total organic carbon (TOC) in the samples analyzed was accounted for by these acids. Oxalate constituted approximately 40% of the TOC in the nonconvective layer samples. Oxalate was found to be approximately 3 to 4 times higher in concentration in the nonconvective layer than in the convective layer. During FY 1993, LC methods for analyzing LWMA, and two chelators N-(2-hydroxyethyl) ethylenediaminetriacetic acid and EDTA, were transferred to personnel in the Analytical Chemistry Laboratory and the 222-S laboratory.

  3. Leak detection method

    International Nuclear Information System (INIS)

    1978-01-01

    This invention provides a method for removing nuclear fuel elements from a fabrication building while at the same time testing the fuel elements for leaks without releasing contaminants from the fabrication building or from the fuel elements. The vacuum source used, leak detecting mechanism and fuel element fabrication building are specified to withstand environmental hazards. (UK)

  4. Design of a nitrogen purification system with cryogenic method for neutrino detection.

    Science.gov (United States)

    Peng, Zhang; Zhongjun, Hu; Bingming, Wang; Qing, Li

    2018-04-04

    In order to detect the neutrino with liquid scintillation detector, high-purity nitrogen is essential for gas stripping in this detector. Therefore, it is necessary to design a purification system for the detector to purify nitrogen. Using the method of low temperature adsorption for the purification system, the key designs including the flow path, the adsorber and the selection of activated carbon, are introduced in this study. In these designs, the selection of activated carbon is the most important because the adsorption characteristic of the carbon is related to the performance of the purification system. The method of grand canonical ensemble Monte Carlo is adopted to simulate the adsorption of radon by the activated carbon with its slit pore model. Using this method, the working temperature and the key characteristic of the activated carbon are obtained. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Development of Coincidence Method for Determination Thermal Neutron Flux on RSG-GAS

    International Nuclear Information System (INIS)

    Bakhri, Syaiful; Hamzah, Amir

    2004-01-01

    The research to develop detection radiation system using coincidence method has been done to determine thermal neutron flux in RS1 and RS2 irradiation facilities RSG-GAS. At this research has arranged beta-gamma coincidence equipment system and parameter of measurement according to Au-198 beta-gamma spectrum. Gold foils that have irradiated for period of time, counted, and the activities of radiation is analyzed to get neutron flux. Result of research indicate that systems measurement of absolute activity with gamma beta coincidence method functioning well and can be applied at activity measurement of gold foil for irradiation facility characterization. The results show that thermal neutron flux in RS1 and RS2, respectively is 2.007E+12 n/cm 2 s and 2.147E+12 n/cm 2 s. To examine the system performance, the result was compared to measure activity using high resolution of Hp Ge detector and achieved discrepancy is about 1.26% and 6.70%. (author)

  6. Simple gas chromatographic method for furfural analysis.

    Science.gov (United States)

    Gaspar, Elvira M S M; Lopes, João F

    2009-04-03

    A new, simple, gas chromatographic method was developed for the direct analysis of 5-hydroxymethylfurfural (5-HMF), 2-furfural (2-F) and 5-methylfurfural (5-MF) in liquid and water soluble foods, using direct immersion SPME coupled to GC-FID and/or GC-TOF-MS. The fiber (DVB/CAR/PDMS) conditions were optimized: pH effect, temperature, adsorption and desorption times. The method is simple and accurate (RSDfurfurals will contribute to characterise and quantify their presence in the human diet.

  7. Prospects of Optical Single Atom Detection in Noble Gas Solids for Measurements of Rare Nuclear Reactions

    Science.gov (United States)

    Singh, Jaideep; Bailey, Kevin G.; Lu, Zheng-Tian; Mueller, Peter; O'Connor, Thomas P.; Xu, Chen-Yu; Tang, Xiaodong

    2013-04-01

    Optical detection of single atoms captured in solid noble gas matrices provides an alternative technique to study rare nuclear reactions relevant to nuclear astrophysics. I will describe the prospects of applying this approach for cross section measurements of the ^22Ne,,),25Mg reaction, which is the crucial neutron source for the weak s process inside of massive stars. Noble gas solids are a promising medium for the capture, detection, and manipulation of atoms and nuclear spins. They provide stable and chemically inert confinement for a wide variety of guest species. Because noble gas solids are transparent at optical wavelengths, the guest atoms can be probed using lasers. We have observed that ytterbium in solid neon exhibits intersystem crossing (ISC) which results in a strong green fluorescence (546 nm) under excitation with blue light (389 nm). Several groups have observed ISC in many other guest-host pairs, notably magnesium in krypton. Because of the large wavelength separation of the excitation light and fluorescence light, optical detection of individual embedded guest atoms is feasible. This work is supported by DOE, Office of Nuclear Physics, under contract DE-AC02-06CH11357.

  8. Subsurface biogenic gas rations associated with hydrocarbon contamination

    International Nuclear Information System (INIS)

    Marrin, D.L.

    1991-01-01

    Monitoring the in situ bioreclamation of organic chemicals in soil is usually accomplished by collecting samples from selected points during the remediation process. This technique requires the installation and sampling of soil borings and does not allow for continuous monitoring. The analysis of soil vapor overlying hydrocarbon-contaminated soil and groundwater has been used to detect the presence of nonaqueous phase liquids (NAPL) and to locate low-volatility hydrocarbons that are not directly detected by more conventional soil gas methods. Such soil vapor sampling methods are adaptable to monitoring the in situ bioremediation of soil and groundwater contamination. This paper focuses on the use of biogenic gas ratio in detecting the presence of crude oil and gasoline in the subsurface

  9. On-Site Detection as a Countermeasure to Chemical Warfare/Terrorism.

    Science.gov (United States)

    Seto, Y

    2014-01-01

    On-site monitoring and detection are necessary in the crisis and consequence management of wars and terrorism involving chemical warfare agents (CWAs) such as sarin. The analytical performance required for on-site detection is mainly determined by the fatal vapor concentration and volatility of the CWAs involved. The analytical performance for presently available on-site technologies and commercially available on-site equipment for detecting CWAs interpreted and compared in this review include: classical manual methods, photometric methods, ion mobile spectrometry, vibrational spectrometry, gas chromatography, mass spectrometry, sensors, and other methods. Some of the data evaluated were obtained from our experiments using authentic CWAs. We concluded that (a) no technologies perfectly fulfill all of the on-site detection requirements and (b) adequate on-site detection requires (i) a combination of the monitoring-tape method and ion-mobility spectrometry for point detection and (ii) a combination of the monitoring-tape method, atmospheric pressure chemical ionization mass spectrometry with counterflow introduction, and gas chromatography with a trap and special detectors for continuous monitoring. The basic properties of CWAs, the concept of on-site detection, and the sarin gas attacks in Japan as well as the forensic investigations thereof, are also explicated in this article. Copyright © 2014 Central Police University.

  10. PDMS membranes as sensing element in optical sensors for gas detection in water

    Directory of Open Access Journals (Sweden)

    Stefania Torino

    2017-11-01

    Full Text Available Polydimethylsiloxane (PDMS has been introduced the first time about 20years ago. This polymer is worldwide used for the rapid prototyping of microfluidic device through a replica molding process. However, the great popularity of PDMS is not only related to its easy processability, but also to its chemical and physical properties. For its interesting properties, the polymer has been implied for several applications, including sensing. In this work, we investigated how to use functionalized PDMS membranes as sensing elements in optical sensors for gas detection in water samples. Keywords: Polydimethylsiloxane (PDMS, Surface Plasmon Resonance (SPR sensors, Gas sensor

  11. Optical methods to study the gas exchange processes in large diesel engines

    Energy Technology Data Exchange (ETDEWEB)

    Gros, S.; Hattar, C. [Wartsila Diesel International Oy, Vaasa (Finland); Hernberg, R.; Vattulainen, J. [Tampere Univ. of Technology, Tampere (Finland). Plasma Technology Lab.

    1996-12-01

    To be able to study the gas exchange processes in realistic conditions for a single cylinder of a large production-line-type diesel engine, a fast optical absorption spectroscopic method was developed. With this method line-of-sight UV-absorption of SO{sub 2} contained in the exhaust gas was measured as a function of time in the exhaust port area in a continuously fired medium speed diesel engine type Waertsilae 6L20. SO{sub 2} formed during the combustion from the fuel contained sulphur was used as a tracer to study the gas exchange as a function of time in the exhaust channel. In this case of a 4-stroke diesel engine by assuming a known concentration of SO{sub 2} in the exhaust gas after exhaust valve opening and before inlet and exhaust valve overlap period, the measured optical absorption was used to determine the gas density and further the instantaneous exhaust gas temperature during the exhaust cycle. (author)

  12. Physical Properties of Gas Hydrates: A Review

    Energy Technology Data Exchange (ETDEWEB)

    Gabitto, Jorge [Prairie View A& M University; Tsouris, Costas [ORNL

    2010-01-01

    Methane gas hydrates in sediments have been studied by several investigators as a possible future energy resource. Recent hydrate reserves have been estimated at approximately 1016?m3 of methane gas worldwide at standard temperature and pressure conditions. In situ dissociation of natural gas hydrate is necessary in order to commercially exploit the resource from the natural-gas-hydrate-bearing sediment. The presence of gas hydrates in sediments dramatically alters some of the normal physical properties of the sediment. These changes can be detected by field measurements and by down-hole logs. An understanding of the physical properties of hydrate-bearing sediments is necessary for interpretation of geophysical data collected in field settings, borehole, and slope stability analyses; reservoir simulation; and production models. This work reviews information available in literature related to the physical properties of sediments containing gas hydrates. A brief review of the physical properties of bulk gas hydrates is included. Detection methods, morphology, and relevant physical properties of gas-hydrate-bearing sediments are also discussed.

  13. A multi-residue method for the analysis of pesticides and pesticide degradates in water using HLB solid-phase extraction and gas chromatography-ion trap mass spectrometry

    Science.gov (United States)

    Hladik, M.L.; Smalling, K.L.; Kuivila, K.M.

    2008-01-01

    A method was developed for the analysis of over 60 pesticides and degradates in water by HLB solid-phase extraction and gas-chromatography/mass spectrometry. Method recoveries and detection limits were determined using two surface waters with different dissolved organic carbon (DOC) concentrations. In the lower DOC water, recoveries and detection limits were 80%-108% and 1-12 ng/L, respectively. In the higher DOC water, the detection limits were slightly higher (1-15 ng/L). Additionally, surface water samples from four sites were analyzed and 14 pesticides were detected with concentrations ranging from 4 to 1,200 ng/L. ?? 2008 Springer Science+Business Media, LLC.

  14. Method and means for filtering polychlorinated biphenyls from a gas stream

    International Nuclear Information System (INIS)

    Sowinski, R.F.

    1992-01-01

    This patent describes a method of filtering, adjacent to an end user-customer's residence or business in which at least a single gas appliance is located, a natural gas stream in which polychlorinated biphenyls (PCB's) and degraded PCB products have been concentrated at sufficient levels to be a health threat in a natural gas gathering and distributing network. It comprises: introducing the natural gas stream to a filter selected from a group that includes impingement, absorbing and adsorbing media whereby PCB's and degraded PCB products concentrated in the gas stream at sufficient levels to be a health threat by a periodic loading of the natural gas within the gathering and distributing network, are filtered from the gas stream and captured irrespective of mode of transport, passing the filtered natural gas stream to the customer's gas appliance wherein safe use of the energy associated with the stream occurs; periodically and safely removing the filter, inserting a new filter in place of the removed filter

  15. Hydrogen extraction from liquid lithium-lead alloy by gas-liquid contact method

    International Nuclear Information System (INIS)

    Xie Bo; Weng Kuiping; Hou Jianping; Yang Guangling; Zeng Jun

    2013-01-01

    Hydrogen extraction experiment from liquid lithium-lead alloy by gas-liquid contact method has been carried out in own liquid lithium-lead bubbler (LLLB). Experimental results show that, He is more suitable than Ar as carrier gas in the filler tower. The higher temperature the tower is, the greater hydrogen content the tower exports. Influence of carrier gas flow rate on the hydrogen content in the export is jagged, no obvious rule. Although the difference between experimental results and literature data, but it is feasible that hydrogen isotopes extraction experiment from liquid lithium-lead by gas-liquid contact method, and the higher extraction efficiency increases with the growth of the residence time of the alloy in tower. (authors)

  16. Investigation of Gasochromic Rhodium Complexes Towards Their Reactivity to CO and Integration into an Optical Gas Sensor for Fire Gas Detection

    Directory of Open Access Journals (Sweden)

    Carolin Pannek

    2018-06-01

    Full Text Available The detection of the toxic gas carbon monoxide (CO in the low ppm range is required in different applications. We present a study of the reactivity of different gasochromic rhodium complexes towards the toxic gas carbon monoxide (CO. Therefore, variations of binuclear rhodium complexes with different ligands were prepared. They were characterized by FTIR spectroscopy, 1H NMR spectroscopy, and differential scanning calorimetry. All complexes are spectroscopically distinguishable and temperature stable up to at least 187 °C. The gasochromic behavior of all different compounds was tested. Therefore, the compounds were dissolved in toluene and exposed to 100 ppm CO for 10 min to investigate their gas sensitivity and reaction velocity. The changes in the transmission spectra were recorded by UV/vis spectroscopy. Furthermore, a significant influence of the solvent to the color dyes’ gasochromic reaction and behavior was observed. After characterization, one complex was transferred as sensing element into an optical gas sensor. Two different measurement principles (reflection- and waveguide-based were built up and tested towards their capability as gasochromic CO sensors. Finally, different gas-dependent measurements were carried out.

  17. Characterization and calibration of gas sensor systems at ppb level—a versatile test gas generation system

    Science.gov (United States)

    Leidinger, Martin; Schultealbert, Caroline; Neu, Julian; Schütze, Andreas; Sauerwald, Tilman

    2018-01-01

    This article presents a test gas generation system designed to generate ppb level gas concentrations from gas cylinders. The focus is on permanent gases and volatile organic compounds (VOCs) for applications like indoor and outdoor air quality monitoring or breath analysis. In the design and the setup of the system, several issues regarding handling of trace gas concentrations have been considered, addressed and tested. This concerns not only the active fluidic components (flow controllers, valves), which have been chosen specifically for the task, but also the design of the fluidic tubing regarding dead volumes and delay times, which have been simulated for the chosen setup. Different tubing materials have been tested for their adsorption/desorption characteristics regarding naphthalene, a highly relevant gas for indoor air quality monitoring, which has generated high gas exchange times in a previous gas mixing system due to long time adsorption/desorption effects. Residual gas contaminations of the system and the selected carrier air supply have been detected and quantified using both an analytical method (GC-MS analysis according to ISO 16000-6) and a metal oxide semiconductor gas sensor, which detected a maximum contamination equivalent to 28 ppb of carbon monoxide. A measurement strategy for suppressing even this contamination has been devised, which allows the system to be used for gas sensor and gas sensor system characterization and calibration in the low ppb concentration range.

  18. Detection methods of irradiated foodstuffs

    Energy Technology Data Exchange (ETDEWEB)

    Ponta, C C; Cutrubinis, M; Georgescu, R [IRASM Center, Horia Hulubei National Institute for Physics and Nuclear Engineering, PO Box MG-6, RO-077125 Magurele-Bucharest (Romania); Mihai, R [Life and Environmental Physics Department, Horia Hulubei National Institute for Physics and Nuclear Engineering, PO Box MG-6, RO-077125 Magurele-Bucharest (Romania); Secu, M [National Institute of Materials Physics, Bucharest (Romania)

    2005-07-01

    food is marketed as irradiated or if irradiated goods are sold without the appropriate labeling, then detection tests should be able to prove the authenticity of the product. For the moment in Romania there is not any food control laboratory able to detect irradiated foodstuffs. The Technological Irradiation Department coordinates and co finances a research project aimed to establish the first Laboratory of Irradiated Foodstuffs Detection. The detection methods studied in this project are the ESR methods (for cellulose EN 1787/2000, bone EN 1786/1996 and crystalline sugar EN 13708/2003), the TL method (EN 1788/2001), the PSL method (EN 13751/2002) and the DNA Comet Assay method (EN 13784/2001). The above detection methods will be applied on various foodstuffs such: garlic, onion, potatoes, rice, beans, wheat, maize, pistachio, sunflower seeds, raisins, figs, strawberries, chicken, beef, fish, pepper, paprika, thyme, laurel and mushrooms. As an example of the application of a detection method there are presented the ESR spectra of irradiated and nonirradiated paprika acquired according to ESR detection method for irradiated foodstuffs containing cellulose. First of all it can be noticed that the intensity of the signal of cellulose is much higher for the irradiated sample than that for the nonirradiated one and second that appear two radiation specific signals symmetrical to the cellulose signal. These two radiation specific signals prove the irradiation treatment of paprika. (author)

  19. Method for manufacturing raw mass for gas concrete

    Energy Technology Data Exchange (ETDEWEB)

    Hellestam, C J.S.

    1949-06-30

    A method is described for processing a raw mass of oil shale and limestone directly useable for the production of gas concrete, characterized in that the processing is divided into three partial processes, of which the first comprises a pyrolysis with extraction of oil, shale gas, hydrogen sulfide and shale coke; the second, burning of the shale coke while preventing the fusing temperature from being exceeded; and the third partial process is a continued burning at higher temperature in the range of 1100/sup 0/C after the addition of limestone and, if required, extra fuel.

  20. Spices, irradiation and detection methods

    International Nuclear Information System (INIS)

    Sjoeberg, A.M.; Manninen, M.

    1991-01-01

    This paper is about microbiological aspects of spices and microbiological methods to detect irradiated food. The proposed method is a combination of the Direct Epifluorescence Filter Technique (DEFT) and the Aerobic Plate Count (APC). The evidence for irradiation of spices is based on the demonstration of a higher DEFT count than the APC. The principle was first tested in our earlier investigation in the detection of irradiation of whole spices. The combined DEFT+APC procedure was found to give a fairly reliable indication of whether or not a whole spice sample had been irradiated. The results are given (8 figs, 22 refs)

  1. Gas sealing welding method and device for nuclear fuel rod

    International Nuclear Information System (INIS)

    Seki, Masayuki; Nishiyama, Motokuni; Kamimura, Katsuichiro; Yagi, Eiji; Nakase, Tsuyoshi; Kobogata, Sadao; Taniguchi, Jun-ichi; Uesugi, Yoshisaku.

    1995-01-01

    An end plug and a cladding tube are held by clamping, respectively, by opposing movable electrode and static electrode. The movable electrode is forwarded toward the static electrode. The end plug and the cladding tube are abutted and held at a slight gap between their end faces. A region to be welded is surrounded by a pressurizing chamber and the side of the chamber is evacuated and He gas is filled in the cladding tube. Then, one of the electrodes is forwarded, to seal the abutted end faces of the end plug and the cladding tube. Then, pressure and welding current required for welding are applied to the abutted ends, and He gas is sealed in the vessel. The displacement of pressurization caused by slipping when the required pressure is applied to the abutted ends is detected by a sensor, and the operation of the welding control device for starting current supply is terminated by the detection signals. Abutment accuracy between the abutment of the cladding tube and the end plug as a nuclear fuel rod can be ensured, to further improve and stabilize the welding quality. (N.H.)

  2. Method and system to facilitate sealing in gas turbines

    Science.gov (United States)

    Morgan, Victor John; Foster, Gregory Thomas; Sarawate, Neelesh Nandkumar

    2017-09-12

    A method and system for sealing between components within a gas turbine is provided. A first recess defined in a first component receives a seal member. A second recess defined in a second component adjacent the first component also receives the seal member. The first and second recesses are located proximate a hot gas path defined through the gas turbine, and define circumferential paths about the turbine axis. The seal member includes a sealing face that extends in a direction substantially parallel to the turbine axis. The seal member also includes a plurality of seal layers, wherein at least one of the seal layers includes at least one stress relief region for facilitating flexing of the first seal member.

  3. Pyrolysis gas chromatographic atomic emission detection for sediments, coals and other petrochemical precursors

    Energy Technology Data Exchange (ETDEWEB)

    Seeley, J.A.; Zeng, Y.D.; Uden, P.C.; Eglinton, T.I.; Ericson, I. (Massachusetts University, Amherst, MA (USA). Dept. of Chemistry)

    1992-09-01

    On-line flash pyrolysis coupled to a capillary gas chromatograph for the characterization of marine sediments, coals and other heterogeneous solid samples is described. A helium microwave-induced plasma is used for chromatographic detection by atomic emission spectrometry. Simultaneous multi-element detection is achieved with a photodiode array detector. The optical path of the gas chromatographic atomic emission detector is purged with helium, allowing simultaneous, sensitive detection of atomic emission from sulfur 181 nm, phosphorous 186 nm, arsenic 189 nm, selenium 196 nm and carbon 193 nm. Several sediment and coal samples have been analysed for their carbon, nitrogen, sulfur, oxygen, phosphorous, arsenic and selenium content. Qualitative information indicating the occurrence and distribution of these elements in the samples can be used to gauge the relative stage of diagenetic evolution of the samples and provide information on their depositional environment. In some instances the chromatographic behaviour of the compounds produced upon pyrolysis is improved through on-line alkylation. This on-line derivatization is achieved by adding liquid reagents to the pyrolysis probe or by adding liquid reagents to the pyrolysis probe or by adding solid reagents either to the solid sample or by packing the reagent in the injection port of the chromatograph.

  4. Increasing the pump-up rate to polarize 3He gas using spin-exchange optical pumping method

    International Nuclear Information System (INIS)

    Lee, W.T.; Tong Xin; Rich, Dennis; Liu Yun; Fleenor, Michael; Ismaili, Akbar; Pierce, Joshua; Hagen, Mark; Dadras, Jonny; Robertson, J. Lee

    2009-01-01

    In recent years, polarized 3 He gas has increasingly been used as neutron polarizers and polarization analyzers. Two of the leading methods to polarize the 3 He gas are the spin-exchange optical pumping (SEOP) method and the meta-stable exchange optical pumping (MEOP) method. At present, the SEOP setup is comparatively compact due to the fact that it does not require the sophisticated compressor system used in the MEOP method. The temperature and the laser power available determine the speed, at which the SEOP method polarizes the 3 He gas. For the quantity of gas typically used in neutron scattering work, this speed is independent of the quantity of the gas required, whereas the polarizing time using the MEOP method is proportional to the quantity of gas required. Currently, using the SEOP method to polarize several bar-liters of 3 He to 70% polarization would require 20-40 h. This is an order of magnitude longer than the MEOP method for the same quantity of gas and polarization. It would therefore be advantageous to speed up the SEOP process. In this article, we analyze the requirements for temperature, laser power, and the type of alkali used in order to shorten the time required to polarize 3 He gas using the SEOP method.

  5. Modification of fuel failure detection system at multi-purpose reactor RSG-GAS, BATAN

    International Nuclear Information System (INIS)

    Haruyama, Mitsuo; Shitomi, Hajime; Nakamura, Kiyoshi

    2003-03-01

    As one of the technical cooperation activity based on the Annex III, the Cooperation in the Area of Reactor Physics and Technology, of the Arrangement between the National Energy Agency (BATAN) and the Japan Atomic Energy Research Institute (JAERI), the modification of the Fuel Failure Detection System (FFDS) was carried out by the joint work at the Multi-purpose Reactor RSG-G.A. Siwabessy (RSG-GAS). The system takes the delayed neutron detection method. In normal state, as the background, it measures the gloss delayed neutron concentration emitted in the primary coolant from the fission product (FP) nuclides, which are resulted from a very small amount of fissile material contamination on the fuel plate surface at the fabrication process. When a failure happened at fuel cladding, FP leaks from the fuel meat into the primary coolant. The system shows so higher indication than at normal state, then, the fuel failure can be detected at the early stage and be minimized the damages to the reactor facility and to the environment. The system has been installed at first since November 1994 and applied for reactor operation. However, recently it is not easy to maintain the system for aging degradation and shortage of the spare units and the parts difficult to find in the markets. The modification of FFDS is required for safe and steady reactor operation. The design requirements of the modification are, - To save the system units currently used and the spares on hand as long as practicable, and/or - To replace the system units with those easy to maintain or to obtain at the markets. The modified system obtained around twice of higher sensitivity for delayed neutron detection than before and more reliable monitoring possibility with redundancy. The specification, installation, adjustment methods and characteristics of the modified system and the modus operandi of FFDS at high power reactor operation are described in this paper. (author)

  6. Formation of hydrocarbons in irradiated Brazilian beans: gas chromatographic analysis to detect radiation processing

    International Nuclear Information System (INIS)

    Villavicencio, A.L.C.H.; Mancini-Filho, J.; Hartmann, M.; Ammon, J.; Delincee, H.

    1997-01-01

    Radiation processing of beans, which are a major source of dietary protein in Brazil, is a valuable alternative to chemical fumigation to combat postharvest losses due to insect infestation. To ensure free consumer choice, irradiated food will be labeled as such, and to enforce labeling, analytical methods to detect the irradiation treatment in the food product itself are desirable. In two varieties of Brazilian beans, Carioca and Macacar beans, the radiolytic formation of hydrocarbons formed after alpha and beta cleavage, with regard to the carbonyl group in triglycerides, have been studied. Using gas chromatographic analysis of these radiolytic hydrocarbons, different yields per precursor fatty acid are observed for the two types of beans. However, the typical degradation pattern allows the identification of the irradiation treatment in both bean varieties, even after 6 months of storage

  7. Detection and quantification of adulteration of sesame oils with vegetable oils using gas chromatography and multivariate data analysis.

    Science.gov (United States)

    Peng, Dan; Bi, Yanlan; Ren, Xiaona; Yang, Guolong; Sun, Shangde; Wang, Xuede

    2015-12-01

    This study was performed to develop a hierarchical approach for detection and quantification of adulteration of sesame oil with vegetable oils using gas chromatography (GC). At first, a model was constructed to discriminate the difference between authentic sesame oils and adulterated sesame oils using support vector machine (SVM) algorithm. Then, another SVM-based model is developed to identify the type of adulterant in the mixed oil. At last, prediction models for sesame oil were built for each kind of oil using partial least square method. To validate this approach, 746 samples were prepared by mixing authentic sesame oils with five types of vegetable oil. The prediction results show that the detection limit for authentication is as low as 5% in mixing ratio and the root-mean-square errors for prediction range from 1.19% to 4.29%, meaning that this approach is a valuable tool to detect and quantify the adulteration of sesame oil. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. A quantitative method to detect explosives and selected semivolatiles in soil samples by Fourier transform infrared spectroscopy

    International Nuclear Information System (INIS)

    Clapper-Gowdy, M.; Dermirgian, J.; Robitaille, G.

    1995-01-01

    This paper describes a novel Fourier transform infrared (FTIR) spectroscopic method that can be used to rapidly screen soil samples from potentially hazardous waste sites. Samples are heated in a thermal desorption unit and the resultant vapors are collected and analyzed in a long-path gas cell mounted in a FTIR. Laboratory analysis of a soil sample by FTIR takes approximately 10 minutes. This method has been developed to identify and quantify microgram concentrations of explosives in soil samples and is directly applicable to the detection of selected volatile organics, semivolatile organics, and pesticides

  9. Atmospheric Detection of Perfluorotributyl Amine, an Uncharacterized Long-Lived Greenhouse Gas

    Science.gov (United States)

    Hong, A. C.; Young, C. J.; Mabury, S. A.

    2012-12-01

    Poly- and perfluoroalkyl substances (PFASs) are trace atmospheric constituents of radiative significance. In the atmosphere, PFASs may represent a class of potent long-lived greenhouse gases (LLGHGs) because they possess long lifetimes and exceptionally strong absorption bands in the infrared (IR) spectral region where other naturally occurring greenhouse gases (GHGs) do not absorb. The Intergovernmental Panel on Climate Change determined the radiative forcing (RF) of halocarbons to be +0.337 [± 0.03] W m-2, accounting for 13 % of the total RF attributed to LLGHGs. Although this value claims high certainty, it does not represent the actual perturbation from all environmentally relevant PFASs. Here we present the radiative efficiency (RE) and atmospheric concentration of a previously uncharacterized and unreported PFAS, perfluorotributyl amine (PFBAm). To assess the radiative properties of PFBAm, IR spectra were acquired by Fourier transform spectroscopy at 0.25 cm-1 resolution over the spectral range 0-2500 cm-1 at 296 K. The total integrated band strength, 7.08 x 10-16 cm2 molec-1 cm-1, was used to derive the cloudy-sky, instantaneous RE assuming a 0 to 1 ppbv change in concentration.The RE of PFBAm is calculated to be 0.86 W m-2 ppb-1, exceeding the RE of SF5CF3, the most effective GHG on a per molecule basis as reported in the literature to date. To evaluate the RF of PFBAm, a highly sensitive and selective method for detection was developed and validated. PFBAm was cryogenically extracted and pre-concentrated from bulk air samples for the offline detection by a custom-designed manifold coupled to a gas chromatograph-mass spectrometer. Quantitation was achieved by external calibration with a gravimetrically prepared, matrix-matched, authentic gaseous standard. Validation of the sampling method was performed by simultaneous measurement of several legacy chlorofluorocarbons and hydrochlorofluorocarbons. Preliminary results indicate that PFBAm is present in the

  10. Detection of pristine gas two billion years after the Big Bang.

    Science.gov (United States)

    Fumagalli, Michele; O'Meara, John M; Prochaska, J Xavier

    2011-12-02

    In the current cosmological model, only the three lightest elements were created in the first few minutes after the Big Bang; all other elements were produced later in stars. To date, however, heavy elements have been observed in all astrophysical environments. We report the detection of two gas clouds with no discernible elements heavier than hydrogen. These systems exhibit the lowest heavy-element abundance in the early universe, and thus are potential fuel for the most metal-poor halo stars. The detection of deuterium in one system at the level predicted by primordial nucleosynthesis provides a direct confirmation of the standard cosmological model. The composition of these clouds further implies that the transport of heavy elements from galaxies to their surroundings is highly inhomogeneous.

  11. Benchmark calculations for evaluation methods of gas volumetric leakage rate

    International Nuclear Information System (INIS)

    Asano, R.; Aritomi, M.; Matsuzaki, M.

    1998-01-01

    A containment function of radioactive materials transport casks is essential for safe transportation to prevent the radioactive materials from being released into environment. Regulations such as IAEA standard determined the limit of radioactivity to be released. Since is not practical for the leakage tests to measure directly the radioactivity release from a package, as gas volumetric leakages rates are proposed in ANSI N14.5 and ISO standards. In our previous works, gas volumetric leakage rates for several kinds of gas from various leaks were measured and two evaluation methods, 'a simple evaluation method' and 'a strict evaluation method', were proposed based on the results. The simple evaluation method considers the friction loss of laminar flow with expansion effect. The strict evaluating method considers an exit loss in addition to the friction loss. In this study, four worked examples were completed for on assumed large spent fuel transport cask (Type B Package) with wet or dry capacity and at three transport conditions; normal transport with intact fuels or failed fuels, and an accident in transport. The standard leakage rates and criteria for two kinds of leak test were calculated for each example by each evaluation method. The following observations are made based upon the calculations and evaluations: the choked flow model of ANSI method greatly overestimates the criteria for tests ; the laminar flow models of both ANSI and ISO methods slightly overestimate the criteria for tests; the above two results are within the design margin for ordinary transport condition and all methods are useful for the evaluation; for severe condition such as failed fuel transportation, it should pay attention to apply a choked flow model of ANSI method. (authors)

  12. Gas permeation measurement under defined humidity via constant volume/variable pressure method

    KAUST Repository

    Jan Roman, Pauls

    2012-02-01

    Many industrial gas separations in which membrane processes are feasible entail high water vapour contents, as in CO 2-separation from flue gas in carbon capture and storage (CCS), or in biogas/natural gas processing. Studying the effect of water vapour on gas permeability through polymeric membranes is essential for materials design and optimization of these membrane applications. In particular, for amine-based CO 2 selective facilitated transport membranes, water vapour is necessary for carrier-complex formation (Matsuyama et al., 1996; Deng and Hägg, 2010; Liu et al., 2008; Shishatskiy et al., 2010) [1-4]. But also conventional polymeric membrane materials can vary their permeation behaviour due to water-induced swelling (Potreck, 2009) [5]. Here we describe a simple approach to gas permeability measurement in the presence of water vapour, in the form of a modified constant volume/variable pressure method (pressure increase method). © 2011 Elsevier B.V.

  13. Organophosphorus pesticide and ester analysis by using comprehensive two-dimensional gas chromatography with flame photometric detection.

    Science.gov (United States)

    Liu, Xiangping; Li, Dengkun; Li, Jiequan; Rose, Gavin; Marriott, Philip J

    2013-12-15

    Thirty-seven phosphorus (P)-containing compounds comprising organophosphorus pesticides and organophosphate esters were analyzed by using comprehensive two-dimensional gas chromatography with flame photometric detection in P mode (GC × GC-FPD(P)), with a non-polar/moderately polar column set. A suitable modulation temperature and period was chosen based on experimental observation. A number of co-eluting peak pairs on the (1)D column were well separated in 2D space. Excellent FPD(P) detection selectivity, responding to compounds containing the P atom, produces clear 2D GC × GC plots with little interference from complex hydrocarbon matrices. Limits of detection (LOD) were within the range of 0.0021-0.048 μmol L(-1), and linear calibration correlation coefficients (R(2)) for all 37 P-compounds were at least 0.998. The P-compounds were spiked in 2% diesel and good reproducibility for their response areas and retention times was obtained. Spiked recoveries were 88%-157% for 5 μg L(-1) and 80%-138% for 10 μg L(-1) spiked levels. Both (1)tR and (2)tR shifts were noted when the content of diesel was in excess of 5% in the matrix. Soil samples were analyzed by using the developed method; some P-compounds were positively detected. In general, this study shows that GC × GC-FPD(P) is an accurate, sensitive and simple method for P-compound analysis in complicated environmental samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. CANDU pressure tube leak detection by annulus gas dew point measurement. A critical review

    International Nuclear Information System (INIS)

    Greening, F.R.

    2017-01-01

    In the event of a pressure tube leak from a small through-wall crack during CANDU reactor operations, there is a regulatory requirement - referred to as Leak Before Break (LBB) - for the licensee to demonstrate that there will be sufficient time for the leak to be detected and the reactor shut down before the crack grows to the critical size for fast-uncontrolled rupture. In all currently operating CANDU reactors, worldwide, this LBB requirement is met via continuous dew point measurements of the CO_2 gas circulating in the reactor's Annulus Gas System (AGS). In this paper the historical development and current status of this leak detection capability is reviewed and the use of moisture injection tests as a verification procedure is critiqued. It is concluded that these tests do not represent AGS conditions that are to be expected in the event of a real pressure tube leak.

  15. CANDU pressure tube leak detection by annulus gas dew point measurement. A critical review

    Energy Technology Data Exchange (ETDEWEB)

    Greening, F.R. [CTS-NA, Tiverton, ON (Canada)

    2017-03-15

    In the event of a pressure tube leak from a small through-wall crack during CANDU reactor operations, there is a regulatory requirement - referred to as Leak Before Break (LBB) - for the licensee to demonstrate that there will be sufficient time for the leak to be detected and the reactor shut down before the crack grows to the critical size for fast-uncontrolled rupture. In all currently operating CANDU reactors, worldwide, this LBB requirement is met via continuous dew point measurements of the CO{sub 2} gas circulating in the reactor's Annulus Gas System (AGS). In this paper the historical development and current status of this leak detection capability is reviewed and the use of moisture injection tests as a verification procedure is critiqued. It is concluded that these tests do not represent AGS conditions that are to be expected in the event of a real pressure tube leak.

  16. Detecting and Identifying Industrial Gases by a Method Based on Olfactory Machine at Different Concentrations

    OpenAIRE

    Sun, Yunlong; Luo, Dehan; Li, Hui; Zhu, Chuchu; Xu, Ou; Gholam Hosseini, Hamid

    2018-01-01

    Gas sensors have been widely reported for industrial gas detection and monitoring. However, the rapid detection and identification of industrial gases are still a challenge. In this work, we measure four typical industrial gases including CO2, CH4, NH3, and volatile organic compounds (VOCs) based on electronic nose (EN) at different concentrations. To solve the problem of effective classification and identification of different industrial gases, we propose an algorithm based on the selective ...

  17. Multivariate methods for the detection of greenhouse-gas-induced climate change

    International Nuclear Information System (INIS)

    Santer, B.D.; Wigley, T.M.L.; Jones, P.D.; Schlesinger, M.E.

    1990-01-01

    This investigation considers whether observed changes in surface air temperature are consistent with GCM equilibrium response predictions for a doubling of atmospheric CO 2 . The model considered is a version of the Oregon State University (OSU) atmospheric general circulation model (AGCM). The study consists of three stages. In the first stage the authors examine the spatial structure of changes in the annual mean and annual cycle for surface air temperature, mean sea-level pressure (SLP) and precipitation rate. Signal-to-noise (S/N) ratios or equivalent test statistics are then computed (using the 1 x CO 2 and 2 x CO 2 data) in order to identify variables most useful for detection purposes. Changes in both means and variances are considered as possible detection parameters. The highest S/N ratios are obtained for annual-mean and winter surface air temperature, and the lowest S/N ratios are obtained for SLP. There are significant increases in the temporal and spatial variability of precipitation, and significant decreases in the temporal and spatial variability of surface air temperature

  18. Improved GLR method to instrument failure detection

    International Nuclear Information System (INIS)

    Jeong, Hak Yeoung; Chang, Soon Heung

    1985-01-01

    The generalized likehood radio(GLR) method performs statistical tests on the innovations sequence of a Kalman-Buchy filter state estimator for system failure detection and its identification. However, the major drawback of the convensional GLR is to hypothesize particular failure type in each case. In this paper, a method to solve this drawback is proposed. The improved GLR method is applied to a PWR pressurizer and gives successful results in detection and identification of any failure. Furthmore, some benefit on the processing time per each cycle of failure detection and its identification can be accompanied. (Author)

  19. Thermoelectric SQUID method for the detection of segregations

    Science.gov (United States)

    Hinken, Johann H.; Tavrin, Yury

    2000-05-01

    Aero engine turbine discs are most critical parts. Material inhomogeneities can cause disc fractures during the flight with fatal air disasters. Nondestructive testing (NDT) of the discs in various machining steps is necessary and performed as well as possible. Conventional NDT methods, however, like eddy current testing and ultrasonic testing have unacceptable limits. For example, subsurface segregations often cannot be detected directly but only indirectly in such cases when cracks already have developed from them. This may be too late. A new NDT method, which we call the Thermoelectric SQUID Method, has been developed. It allows for the detection of metallic inclusions within non-ferromagnetic metallic base material. This paper describes the results of a feasibility study on aero engine turbine discs made from Inconel® 718. These contained segregations that had been detected before by anodic etching. With the Thermoelectric SQUID Method, these segregations were detected again, and further segregations below the surfaces have been found, which had not been detected before. For this new NDT method the disc material is quasi-transparent. The Thermoelectric SQUID Method is also useful to detect distributed and localized inhomogeneities in pure metals like niobium sheets for particle accelerators.

  20. Characterization of biomass producer gas as fuel for stationary gas engines in combined heat and power production

    DEFF Research Database (Denmark)

    Ahrenfeldt, Jesper

    2008-01-01

    The aim of this project has been the characterization of biomass producer gas as a fuel for stationary gas engines in heat and power production. More than 3200 hours of gas engine operation, with producer gas as fuel, has been conducted at the biomass gasification combined heat and power (CHP...... different measuring methods. Likewise, no particles were detected in the gas. Considerable amounts of NH3 were measured in the produced gas.An analysis of engine operation at varying load has been carried out. Standard emissions, load and efficiency have been measured at varying operating conditions ranging...... from 50% to 90% load. Biomass producer gas is an excellent lean burn engine fuel: Operation of a natural aspirated engine has been achieved for 1.2...

  1. Detecting and Identifying Industrial Gases by a Method Based on Olfactory Machine at Different Concentrations

    Directory of Open Access Journals (Sweden)

    Yunlong Sun

    2018-01-01

    Full Text Available Gas sensors have been widely reported for industrial gas detection and monitoring. However, the rapid detection and identification of industrial gases are still a challenge. In this work, we measure four typical industrial gases including CO2, CH4, NH3, and volatile organic compounds (VOCs based on electronic nose (EN at different concentrations. To solve the problem of effective classification and identification of different industrial gases, we propose an algorithm based on the selective local linear embedding (SLLE to reduce the dimensionality and extract the features of high-dimensional data. Combining the Euclidean distance (ED formula with the proposed algorithm, we can achieve better classification and identification of four kinds of gases. We compared the classification and recognition results of classical principal component analysis (PCA, linear discriminate analysis (LDA, and PCA + LDA algorithms with the proposed SLLE algorithm after selecting the original data and performing feature extraction. The experimental results show that the recognition accuracy rate of the SLLE reaches 91.36%, which is better than the other three algorithms. In addition, the SLLE algorithm provides more efficient and accurate responses to high-dimensional industrial gas data. It can be used in real-time industrial gas detection and monitoring combined with gas sensor networks.

  2. Distance Measurement Methods for Improved Insider Threat Detection

    Directory of Open Access Journals (Sweden)

    Owen Lo

    2018-01-01

    Full Text Available Insider threats are a considerable problem within cyber security and it is often difficult to detect these threats using signature detection. Increasing machine learning can provide a solution, but these methods often fail to take into account changes of behaviour of users. This work builds on a published method of detecting insider threats and applies Hidden Markov method on a CERT data set (CERT r4.2 and analyses a number of distance vector methods (Damerau–Levenshtein Distance, Cosine Distance, and Jaccard Distance in order to detect changes of behaviour, which are shown to have success in determining different insider threats.

  3. Rancang Bangun Sistem Pengaman Kebocoran Gas LPG (Liquefied Petroleum Gas) Menggunakan Mikrokontroler

    OpenAIRE

    Ismai, Reza Lutfi; Suseno, Jatmiko Endro; Suryono, Suryono

    2017-01-01

    Design of LPG gas leakage safety system using microcontroller has been made in this research. The purpose of this research is to make LPG gas sensor circuit to detect LPG gas concentration and make automation systems for LPG gas leakage protection. LPG gas leakage protection system can be applied for the use of LPG gas safely. Component to detect LPG gas concentration use sensor MQ 5 which can gives resistance as the output value which can be converted into voltage through the voltage devider...

  4. Comparative analysis of methods for detecting interacting loci.

    Science.gov (United States)

    Chen, Li; Yu, Guoqiang; Langefeld, Carl D; Miller, David J; Guy, Richard T; Raghuram, Jayaram; Yuan, Xiguo; Herrington, David M; Wang, Yue

    2011-07-05

    Interactions among genetic loci are believed to play an important role in disease risk. While many methods have been proposed for detecting such interactions, their relative performance remains largely unclear, mainly because different data sources, detection performance criteria, and experimental protocols were used in the papers introducing these methods and in subsequent studies. Moreover, there have been very few studies strictly focused on comparison of existing methods. Given the importance of detecting gene-gene and gene-environment interactions, a rigorous, comprehensive comparison of performance and limitations of available interaction detection methods is warranted. We report a comparison of eight representative methods, of which seven were specifically designed to detect interactions among single nucleotide polymorphisms (SNPs), with the last a popular main-effect testing method used as a baseline for performance evaluation. The selected methods, multifactor dimensionality reduction (MDR), full interaction model (FIM), information gain (IG), Bayesian epistasis association mapping (BEAM), SNP harvester (SH), maximum entropy conditional probability modeling (MECPM), logistic regression with an interaction term (LRIT), and logistic regression (LR) were compared on a large number of simulated data sets, each, consistent with complex disease models, embedding multiple sets of interacting SNPs, under different interaction models. The assessment criteria included several relevant detection power measures, family-wise type I error rate, and computational complexity. There are several important results from this study. First, while some SNPs in interactions with strong effects are successfully detected, most of the methods miss many interacting SNPs at an acceptable rate of false positives. In this study, the best-performing method was MECPM. Second, the statistical significance assessment criteria, used by some of the methods to control the type I error rate

  5. Comparative analysis of methods for detecting interacting loci

    Directory of Open Access Journals (Sweden)

    Yuan Xiguo

    2011-07-01

    Full Text Available Abstract Background Interactions among genetic loci are believed to play an important role in disease risk. While many methods have been proposed for detecting such interactions, their relative performance remains largely unclear, mainly because different data sources, detection performance criteria, and experimental protocols were used in the papers introducing these methods and in subsequent studies. Moreover, there have been very few studies strictly focused on comparison of existing methods. Given the importance of detecting gene-gene and gene-environment interactions, a rigorous, comprehensive comparison of performance and limitations of available interaction detection methods is warranted. Results We report a comparison of eight representative methods, of which seven were specifically designed to detect interactions among single nucleotide polymorphisms (SNPs, with the last a popular main-effect testing method used as a baseline for performance evaluation. The selected methods, multifactor dimensionality reduction (MDR, full interaction model (FIM, information gain (IG, Bayesian epistasis association mapping (BEAM, SNP harvester (SH, maximum entropy conditional probability modeling (MECPM, logistic regression with an interaction term (LRIT, and logistic regression (LR were compared on a large number of simulated data sets, each, consistent with complex disease models, embedding multiple sets of interacting SNPs, under different interaction models. The assessment criteria included several relevant detection power measures, family-wise type I error rate, and computational complexity. There are several important results from this study. First, while some SNPs in interactions with strong effects are successfully detected, most of the methods miss many interacting SNPs at an acceptable rate of false positives. In this study, the best-performing method was MECPM. Second, the statistical significance assessment criteria, used by some of the

  6. Year Ahead Demand Forecast of City Natural Gas Using Seasonal Time Series Methods

    Directory of Open Access Journals (Sweden)

    Mustafa Akpinar

    2016-09-01

    Full Text Available Consumption of natural gas, a major clean energy source, increases as energy demand increases. We studied specifically the Turkish natural gas market. Turkey’s natural gas consumption increased as well in parallel with the world‘s over the last decade. This consumption growth in Turkey has led to the formation of a market structure for the natural gas industry. This significant increase requires additional investments since a rise in consumption capacity is expected. One of the reasons for the consumption increase is the user-based natural gas consumption influence. This effect yields imbalances in demand forecasts and if the error rates are out of bounds, penalties may occur. In this paper, three univariate statistical methods, which have not been previously investigated for mid-term year-ahead monthly natural gas forecasting, are used to forecast natural gas demand in Turkey’s Sakarya province. Residential and low-consumption commercial data is used, which may contain seasonality. The goal of this paper is minimizing more or less gas tractions on mid-term consumption while improving the accuracy of demand forecasting. In forecasting models, seasonality and single variable impacts reinforce forecasts. This paper studies time series decomposition, Holt-Winters exponential smoothing and autoregressive integrated moving average (ARIMA methods. Here, 2011–2014 monthly data were prepared and divided into two series. The first series is 2011–2013 monthly data used for finding seasonal effects and model requirements. The second series is 2014 monthly data used for forecasting. For the ARIMA method, a stationary series was prepared and transformation process prior to forecasting was done. Forecasting results confirmed that as the computation complexity of the model increases, forecasting accuracy increases with lower error rates. Also, forecasting errors and the coefficients of determination values give more consistent results. Consequently

  7. Method for studying gas composition in the human mastoid cavity by use of laser spectroscopy.

    Science.gov (United States)

    Lindberg, Sven; Lewander, Märta; Svensson, Tomas; Siemund, Roger; Svanberg, Katarina; Svanberg, Sune

    2012-04-01

    We evaluated a method for gas monitoring in the mastoid cavity using tunable diode laser spectroscopy by comparing it to simultaneously obtained computed tomographic (CT) scans. The presented optical technique measures free gases, oxygen (O2), and water vapor (H2O) within human tissue by use of low-power diode lasers. Laser light was sent into the tip of the mastoid process, and the emerging light at the level of the antrum was captured with a detector placed on the skin. The absorption of H2O was used to monitor the probed gas volume of the mastoid cavity, and it was compared to the CT scan-measured volume. The ratio between O2 absorption and H2O absorption estimated the O2 content in the mastoid cavity and thus the ventilation. The parameters were compared to the grading of mastoid cavities based on the CT scans (n = 31). The reproducibility of the technique was investigated by measuring each mastoid cavity 4 times. Both O2 and H2O were detected with good reproducibility. The H2O absorption and the CT volume correlated (r = 0.69). The average ratio between the normalized O2 absorption and the H2O absorption signals was 0.7, indicating a lower O2 content than in surrounding air (expected ratio, 1.0), which is consistent with previous findings made by invasive techniques. All mastoid cavities with radiologic signs of disease were detected. Laser spectroscopy monitoring appears to be a usable tool for noninvasive investigations of gas composition in the mastoid cavity, providing important clinical information regarding size and ventilation.

  8. Rapid method for the simultaneous detection of boar taint compounds by means of solid phase microextraction coupled to gas chromatography/mass spectrometry.

    Science.gov (United States)

    Verplanken, Kaat; Wauters, Jella; Van Durme, Jim; Claus, Dirk; Vercammen, Joeri; De Saeger, Sarah; Vanhaecke, Lynn

    2016-09-02

    Because of animal welfare issues, the voluntary ban on surgical castration of male piglets, starting January 2018 was announced in a European Treaty. One viable alternative is the fattening of entire male pigs. However, this can cause negative consumer reactions due to the occurrence of boar taint and possibly lead to severe economic losses in pig husbandry. In this study, headspace solid phase microextraction (HS-SPME) coupled to GC-MS was used in the development and optimization of a candidate method for fast and accurate detection of the boar taint compounds. Remarkably fast extraction (45s) of the boar taint compounds from adipose tissue was achieved by singeing the fat with a soldering iron while released volatiles were extracted in-situ using HS-SPME. The obtained method showed good performance characteristics after validation according to CD 2002/657/EC and ISO/IEC 17025 guidelines. Moreover, cross-validation with an in-house UHPLC-HR-Orbitrap-MS method showed good agreement between an in-laboratory method and the new candidate method for the fast extraction and detection of skatole and androstenone, which emphasizes the accuracy of this new SPME-GC-MS method. Threshold detection of the boar taint compounds on a portable GC-MS could not be achieved. However, despite the lack of sensitivity obtained on the latter instrument, a very fast method with run-to-run time of 3.5min for the detection of the boar taint compounds was developed. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Method and apparatus for isotope separation from a gas stream

    International Nuclear Information System (INIS)

    Szoke, A.

    1978-01-01

    A method and apparatus are described for isotope separation and in particular for separating the desired isotope from the gas in which it is contained by irradiating it with a laser. The laser selectively provides kinetic energy to the isotope through inelastic events, monomolecular or bimolecular, in order to cause it to segregate within or fly out of the gas stream in which it is contained

  10. LHCb: A novel method for an absolute luminosity measurement at LHCb using beam-gas imaging

    CERN Multimedia

    Barschel, C

    2013-01-01

    A novel technique to measure the absolute luminosity at the Large Hadron Collider (LHC) using beam-gas interactions has been successfully used in the LHCb experiment. A gas injection device (SMOG) has been installed in the LHCb experiment to increase the pressure around the interaction point during dedicated fills. The Beam Gas Imaging method (BGI) has now the potential to surpass the accuracy of the commonly used van der Meer scan method (VDM). This poster presents the principles of the Beam Gas Imaging method used to measure the beam overlap integral. Furthermore the gas injection increased the accuracy measurement of the so-called ghost charges and also intensities per bunch.

  11. Comparison study on qualitative and quantitative risk assessment methods for urban natural gas pipeline network.

    Science.gov (United States)

    Han, Z Y; Weng, W G

    2011-05-15

    In this paper, a qualitative and a quantitative risk assessment methods for urban natural gas pipeline network are proposed. The qualitative method is comprised of an index system, which includes a causation index, an inherent risk index, a consequence index and their corresponding weights. The quantitative method consists of a probability assessment, a consequences analysis and a risk evaluation. The outcome of the qualitative method is a qualitative risk value, and for quantitative method the outcomes are individual risk and social risk. In comparison with previous research, the qualitative method proposed in this paper is particularly suitable for urban natural gas pipeline network, and the quantitative method takes different consequences of accidents into consideration, such as toxic gas diffusion, jet flame, fire ball combustion and UVCE. Two sample urban natural gas pipeline networks are used to demonstrate these two methods. It is indicated that both of the two methods can be applied to practical application, and the choice of the methods depends on the actual basic data of the gas pipelines and the precision requirements of risk assessment. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.

  12. Methods to assess high-resolution subsurface gas concentrations and gas fluxes in wetland ecosystems

    DEFF Research Database (Denmark)

    Elberling, Bo; Kühl, Michael; Glud, Ronnie Nøhr

    2013-01-01

    The need for measurements of soil gas concentrations and surface fluxes of greenhouse gases at high temporal and spatial resolution in wetland ecosystem has lead to the introduction of several new analytical techniques and methods. In addition to the automated flux chamber methodology for high-re...

  13. Organophosphorus pesticide and ester analysis by using comprehensive two-dimensional gas chromatography with flame photometric detection

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xiangping; Li, Dengkun; Li, Jiequan [Nanjing Centre for Disease Control and Prevention, Zizhulin Street, Gulou 210003, Nanjing (China); Rose, Gavin [Department of Environment and Primary Industries, Macleod Centre, Ernest Jones Drive, Macleod, Vic 3085 (Australia); Marriott, Philip J., E-mail: philip.marriott@monash.edu [Australian Centre for Research on Separation Science, School of Chemistry, Monash University, Wellington Road, Clayton 3800 (Australia)

    2013-12-15

    Highlights: • GC × GC-FPD(P-mode) was applied to detection of 37 phosphorus (P)-containing compounds. • The method improves resolution of P-compounds that coelute in the first dimension. • P-compounds are analyzed with excellent sensitivity supported by cryogenic modulation. • The FPD(P-mode) selectivity allows analysis in high hydrocarbon (H/C) matrix. • Soil samples and spiked chemical weapon compounds in H/C matrix are readily screened. -- Abstract: Thirty-seven phosphorus (P)-containing compounds comprising organophosphorus pesticides and organophosphate esters were analyzed by using comprehensive two-dimensional gas chromatography with flame photometric detection in P mode (GC × GC-FPD(P)), with a non-polar/moderately polar column set. A suitable modulation temperature and period was chosen based on experimental observation. A number of co-eluting peak pairs on the {sup 1}D column were well separated in 2D space. Excellent FPD(P) detection selectivity, responding to compounds containing the P atom, produces clear 2D GC × GC plots with little interference from complex hydrocarbon matrices. Limits of detection (LOD) were within the range of 0.0021–0.048 μmol L{sup −1}, and linear calibration correlation coefficients (R{sup 2}) for all 37 P-compounds were at least 0.998. The P-compounds were spiked in 2% diesel and good reproducibility for their response areas and retention times was obtained. Spiked recoveries were 88%–157% for 5 μg L{sup −1} and 80%–138% for 10 μg L{sup −1} spiked levels. Both {sup 1}t{sub R} and {sup 2}t{sub R} shifts were noted when the content of diesel was in excess of 5% in the matrix. Soil samples were analyzed by using the developed method; some P-compounds were positively detected. In general, this study shows that GC × GC-FPD(P) is an accurate, sensitive and simple method for P-compound analysis in complicated environmental samples.

  14. New method for evaluating irreversible adsorption and stationary phase bleed in gas chromatographic capillary columns.

    Science.gov (United States)

    Wright, Bob W; Wright, Cherylyn W

    2012-10-26

    A novel method is described for the evaluation of irreversible adsorption and column bleed in gas chromatographic (GC) columns using a tandem GC approach. This work specifically determined the degree of irreversible adsorption behavior of specific sulfur and phosphorous containing test probe compounds at levels ranging from approximately 50 picograms (pg) to 1 nanogram (ng) on selected gas chromatographic columns. This method does not replace existing evaluation methods that characterize reversible adsorption but provides an additional tool. The test compounds were selected due to their ease of adsorption and their importance in the specific trace analytical detection methodology being developed. Replicate chromatographic columns with 5% phenylmethylpolysiloxane (PMS), polyethylene glycol (wax), trifluoropropylpolysiloxane (TFP), or 78% cyanopropylpolysiloxane stationary phases from a variety of vendors were evaluated. As expected, the results demonstrate that the different chromatographic phases exhibit differing degrees of irreversible adsorption behavior. The results also indicate that all manufacturers do not produce equally inert columns nor are columns from a given manufacturer identical. The wax-coated columns for the test probes used were more inert as a group than 5% PMS coated columns, and they were more reproducibly manufactured. Both TFP and 78% cyanopropylpolysiloxane columns displayed superior inertness to the test compounds compared to either 5% PMS- or wax-coated columns. Irreversible adsorption behavior was characterized for a limited range of stationary phase film thicknesses. In addition, the method was shown effective for characterizing column bleed and methods to remove bleed components. This method is useful in screening columns for demanding applications and to obtain diagnostic information related to improved preparation methods. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Evaluation of three gas chromatography and two direct mass spectrometry techniques for aroma analysis of dried red bell peppers

    NARCIS (Netherlands)

    Ruth, van S.M.; Boscaini, E.; Mayr, D.; Pugh, J.; Posthumus, M.A.

    2003-01-01

    Three gas chromatography methods and two direct mass spectrometry techniques were compared for the analysis of the aroma of rehydrated diced red bell peppers. Gas chromatography methods included systems with olfactometry detection (GC-O), flame ionisation detection (GC-FID) and mass spectrometry

  16. Appropriate xenon-inhalation speed in xenon-enhanced CT using the end-tidal gas-sampling method

    International Nuclear Information System (INIS)

    Suga, Sadao; Toya, Shigeo; Kawase, Takeshi; Koyama, Hideki; Shiga, Hayao

    1986-01-01

    This report describes some problems when end-tidal xenon gas is substituted for the arterial xenon concentration in xenon-enhanced CT. The authors used a newly developed xenon inhalator with a xenon-gas-concentration analyzer and performed xenon-enhanced CT by means of the ''arterio-venous shunt'' method and the ''end-tidal gas-sampling'' method simultaneously. By the former method, the arterial build-up rate (K) was obtained directly from the CT slices of a blood circuit passing through the phantom. By the latter method, it was calculated from the xenon concentration of end-tidal gas sampled from the mask. The speed of xenon supply was varied between 0.6 - 1.2 L/min. in 11 patients with or without a cerebral lesion. The results revealed that rapid xenon inhalation caused a discrepancy in the arterial K between the ''shunt'' method and the ''end-tidal'' method. This discrepancy may be responsible for the mixing of inhalated gas and expired gas in respiratory dead space, such as the nasal cavity or the mask. The cerebral blood flow was underestimated because of the higher arterial K in the latter method. Too much slow inhalation, however, was timewasting, and it increased the body motion in the subanesthetic state. Therefore, an inhalation speed of the arterial K of as much as 0.2 was ideal to represent the end-tidal xenon concentration for the arterial K in the ''end-tidal gas-sampling'' method. When attention is given to this point, this method may offer a reliable absolute value in xenon-enhanced CT. (author)

  17. Practical Design Guidelines for Fugitive Gas Detection from Unmanned Aerial Vehicles

    Science.gov (United States)

    Tandy, William D., Jr.

    Simulation, design, and analysis are combined in this effort to realize a UAV-scale instrument for fugitive gas detection. The contributing material to the industry begins by extending and correlating an integrated Gaussian plume model useful for instrument predictions and trade studies, regardless of the instrument type or molecule of interest. A variety of generally applicable plots are produced from this foundation, including receiver operator curves for leak rate detectability vs. wind speed, beam diameter vs. leak rate detectability, and plots for required scan densities. The atmospheric and instrument parameter trade studies are followed by hardware-specific analyses applicable to differential absorption lidar (DIAL) instruments. A synopsis of the lessons learned from hands-on experiences in the lab further define the design space for DIAL sensors. The dissertation culminates in the detailed design and analysis of two DIAL instrument concepts. The conclusion is that a DIAL instrument capable of reliably detecting a 50 SCFH plume in winds speeds up to 7 mph is on the threshold of being achievable on a quadcopter platform. Of special note is that the effort was funded by a Pipeline and Hazardous Materials Safety Administration grant and performed in collaboration with Ball Aerospace & Technologies.

  18. Modulation method of scroll compressor based on suction gas bypass

    International Nuclear Information System (INIS)

    Wang Baolong; Han Linjun; Shi Wenxing; Li Xianting

    2012-01-01

    The air conditioners and heat pumps tend to work in much mild environments and part load situations rather than provide the rated full capacity under severe rated testing conditions. Both the capacity and inner compression ratio of the compressor should be regulated according to the working condition for higher energy efficiency and occupants’ comfort. A potential modulating technology of the scroll compressor, suction gas bypass, is investigated in this paper. The principle and operation method are illuminated and the adaptability is validated by experiments and simulations. As a conclusion, an appropriate suction gas bypass can reduce the inner compression loss of the scroll compressor under over compression conditions, enhance the system COP and also largely decrease the heating/cooling capacity of the refrigeration/heat pump system. - Highlights: ► Suction gas bypass (SGB) is an effective regulating method of scroll compressor. ► SGB reduces the inner compression loss under over compression conditions. ► SGB largely decreases the heating/cooling capacity of the refrigeration system.

  19. Possibilities for decreasing detection limits of analytical methods for determination of transformation products of unsymmetrical dimethylhydrazine in environmental samples

    Directory of Open Access Journals (Sweden)

    Bulat Kenessov

    2015-12-01

    Full Text Available Most rockets of middle and heavy class launched from Kazakhstan, Russia, China and other countries still use highly toxic unsymmetrical dimethylhydrazine (UDMH as a liquid propellant. Study of migration, distribution and accumulation of UDMH transformation products in environment and human health impact assessment of space rocket activity are currently complicated due to the absence of analytical methods allowing detection of trace concentrations of these compounds in analyzed samples. This paper reviews methods and approaches, which can be applied for development of such methods. Detection limits at a part-per-trillion (ppt level may be achieved using most selective and sensitive methods based on gas or liquid chromatography in combination of tandem or high-resolution mass spectrometry. In addition, 1000-fold concentration of samples or integrated sample preparation methods, e.g., dynamic headspace extraction, are required. Special attention during development and application of such methods must be paid to purity of laboratory air, reagents, glassware and analytical instruments.

  20. Method for detecting trace impurities in gases

    Science.gov (United States)

    Freund, S.M.; Maier, W.B. II; Holland, R.F.; Beattie, W.H.

    A technique for considerably improving the sensitivity and specificity of infrared spectrometry as applied to quantitative determination of trace impurities in various carrier or solvent gases is presented. A gas to be examined for impurities is liquefied and infrared absorption spectra of the liquid are obtained. Spectral simplification and number densities of impurities in the optical path are substantially higher than are obtainable in similar gas-phase analyses. Carbon dioxide impurity (approx. 2 ppM) present in commercial Xe and ppM levels of Freon 12 and vinyl chloride added to liquefied air are used to illustrate the method.

  1. Development and Establishment of Detection Method of Irradiated Foods

    International Nuclear Information System (INIS)

    Byun, Myung Woo; Lee, Ju Woon; Kim, Dong Ho; Jo, Cheo Run; Kim, Jang Ho; Kim, Kyong Su

    2004-12-01

    The present project was related to the development and establishment of the detection techniques for the safety management of gamma-irradiated food and particularly conducted for the establishment of standard detection method for gamma-irradiated dried spices and raw materials, dried meat and fish powder for processed foods, bean paste powder, red pepper paste powder, soy sauce powder, and starch for flavoring ingredients described in 3, 6, 7 section of Korean Food Standard. Since the approvement of gamma-irradiated food items will be enlarged due to the international tendency for gamma-irradiated food, it was concluded that the establishment of detailed detection methods for each food group is not efficient for the enactment and enforcement of related regulations. For this reason, in order to establish the standard detection method, a detection system for gamma-irradiated food suitable for domestic operation was studied using comparative analysis of domestic and foreign research data classified by items and methods and European Standard as a reference. According to the comparative analyses of domestic and foreign research data and regulations of detection for gamma-irradiated food, it was concluded to be desirable that the optimal detection method should be decided after principal detection tests such as physical, chemical, and biological detection methods are established as standard methods and that the specific descriptions such as pre-treatment of raw materials, test methods, and the evaluation of results should be separately prescribed

  2. Development and Establishment of Detection Method of Irradiated Foods

    Energy Technology Data Exchange (ETDEWEB)

    Byun, Myung Woo; Lee, Ju Woon; Kim, Dong Ho; Jo, Cheo Run; Kim, Jang Ho; Kim, Kyong Su

    2004-12-15

    The present project was related to the development and establishment of the detection techniques for the safety management of gamma-irradiated food and particularly conducted for the establishment of standard detection method for gamma-irradiated dried spices and raw materials, dried meat and fish powder for processed foods, bean paste powder, red pepper paste powder, soy sauce powder, and starch for flavoring ingredients described in 3, 6, 7 section of Korean Food Standard. Since the approvement of gamma-irradiated food items will be enlarged due to the international tendency for gamma-irradiated food, it was concluded that the establishment of detailed detection methods for each food group is not efficient for the enactment and enforcement of related regulations. For this reason, in order to establish the standard detection method, a detection system for gamma-irradiated food suitable for domestic operation was studied using comparative analysis of domestic and foreign research data classified by items and methods and European Standard as a reference. According to the comparative analyses of domestic and foreign research data and regulations of detection for gamma-irradiated food, it was concluded to be desirable that the optimal detection method should be decided after principal detection tests such as physical, chemical, and biological detection methods are established as standard methods and that the specific descriptions such as pre-treatment of raw materials, test methods, and the evaluation of results should be separately prescribed.

  3. [The elaboration of gas chromatographic method of the determination of N-nitrosamines (N-nitrosodimethylamine, N-nitrosodiethylamine) in biological samples (urine)].

    Science.gov (United States)

    Zaytseva, N V; Ulanova, T S; Nurislamova, T V; Popova, N A

    2014-01-01

    The issues of the elaboration of a method for the determination of N-nitrosamines (N-nitrosodimethylamine, N-nitrosodiethylamine) in urine by means of the method of capillary gas chromatography with the use of a thermionic detector are considered. There were performed investigations on the study of the efficacy of the extraction of N-nitrosamines from the urine by steam distillation and gas chromatographic detection of headspace. With the aim of the maximal recovery of N-nitrosamines from the urine and setting parameters of the extraction two method were used to prepare the bioassay for the analysis the alkalization with potassium hydroxide and the addition of salting out reagent--neutral salts of alkali and alkaline earth metals. During the process of performed studies there was found that the greatest degree of extraction of N-nitrosamines from the urine by the method of headspace analysis is achieved if using the salting-out agent in an amount of 16 g of sodium sulfate and for N-nitrosodimethylamine is 99%, for N-nitrosodiethylamine--100%.

  4. Analytical resource assessment method for continuous (unconventional) oil and gas accumulations - The "ACCESS" Method

    Science.gov (United States)

    Crovelli, Robert A.; revised by Charpentier, Ronald R.

    2012-01-01

    The U.S. Geological Survey (USGS) periodically assesses petroleum resources of areas within the United States and the world. The purpose of this report is to explain the development of an analytic probabilistic method and spreadsheet software system called Analytic Cell-Based Continuous Energy Spreadsheet System (ACCESS). The ACCESS method is based upon mathematical equations derived from probability theory. The ACCESS spreadsheet can be used to calculate estimates of the undeveloped oil, gas, and NGL (natural gas liquids) resources in a continuous-type assessment unit. An assessment unit is a mappable volume of rock in a total petroleum system. In this report, the geologic assessment model is defined first, the analytic probabilistic method is described second, and the spreadsheet ACCESS is described third. In this revised version of Open-File Report 00-044 , the text has been updated to reflect modifications that were made to the ACCESS program. Two versions of the program are added as appendixes.

  5. Detection of solvent losses (entrainment) in gas streams of process vessels using radioisotope tracing techniques

    International Nuclear Information System (INIS)

    Wan Zakaria Wan Muhamad Tahir; Juhari Mohd Yusof

    2002-01-01

    Liquid droplets (MDEA aqueous solution) entrained in the gas streams can cause severe problems on chemical plants. On-line detection of liquid entrainment (carry over) into gas streams from process vessel is investigated using radioisotope iodine ( 131 I). In order to obtain information on whether there is any carry-over of MDEA in the vapour space leaving from the process system, a number of test and calibration injections involving the released of certain amount of tracer activity (mCi) at the inlet and overhead lines of the process vessels were made using a special injection device. MDEA solvent- tagged tracer in the overhead line of the designated process vessels was monitored using radiation scintillation detectors mounted externally at specified locations of the vessels. Output pulses (response curves) with respect to time of measurements from all detectors were plotted and analysed for the finger prints of solvent losses leaving the vessels. From this study, no distinguishable peaks were detected at the outlet vessels of the overhead lines. Thus, no significant MDEA solvent losses in the form of vapour being discovered along the gas streams due to the process taking place in the system. (Author)

  6. Detecting Liquefied Petroleum Gas (LPG) at Room Temperature Using ZnSnO3/ZnO Nanowire Piezo-Nanogenerator as Self-Powered Gas Sensor.

    Science.gov (United States)

    Fu, Yongming; Nie, Yuxin; Zhao, Yayu; Wang, Penglei; Xing, Lili; Zhang, Yan; Xue, Xinyu

    2015-05-20

    High sensitivity, selectivity, and reliability have been achieved from ZnSnO3/ZnO nanowire (NW) piezo-nanogenerator (NG) as self-powered gas sensor (SPGS) for detecting liquefied petroleum gas (LPG) at room temperature (RT). After being exposed to 8000 ppm LPG, the output piezo-voltage of ZnSnO3/ZnO NW SPGS under compressive deformation is 0.089 V, much smaller than that in air ambience (0.533 V). The sensitivity of the SPGS against 8000 ppm LPG is up to 83.23, and the low limit of detection is 600 ppm. The SPGS has lower sensitivity against H2S, H2, ethanol, methanol and saturated water vapor than LPG, indicating good selectivity for detecting LPG. After two months, the decline of the sensing performance is less than 6%. Such piezo-LPG sensing at RT can be ascribed to the new piezo-surface coupling effect of ZnSnO3/ZnO nanocomposites. The practical application of the device driven by human motion has also been simply demonstrated. This work provides a novel approach to fabricate RT-LPG sensors and promotes the development of self-powered sensing system.

  7. AN APPLICATION OF FLOW INJECTION ANALYSIS WITH GAS DIFFUSION AND SPECTROPHOTOMETRIC DETECTION FOR THE MONITORING OF DISSOLVED SULPHIDE CONCENTRATION IN ENVIRONMENTAL SAMPLES

    Directory of Open Access Journals (Sweden)

    Malwina Cykowska

    2014-10-01

    Full Text Available The monitoring of the concentration of sulphide is very important from the environment point of view because of high toxicity of hydrogen sulphide. What is more hydrogen sulphide is an important pollution indicator. In many cases the determination of sulphide is very difficult due to complicated matrix of some environmental samples, which causes that most analytical methods cannot be used. Flow injection analysis allows to avoid matrix problem what makes it suitable for a wide range of applications in analytical laboratories. In this paper determination of dissolved sulphide in environmental samples by gas-diffusion flow injection analysis with spectrophotometric detection was presented. Used gas-diffusion separation ensures the elimination of interferences caused by sample matrix and gives the ability of determination of sulphides in coloured and turbid samples. Studies to optimize the measurement conditions and to determine the value of the validation parameters (e.g. limit of detection, limit of quantification, precision, accuracy were carried out. Obtained results confirm the usefulness of the method for monitoring the concentration of dissolved sulphides in water and waste water. Full automation and work in a closed system greatly reduces time of analysis, minimizes consumption of sample and reagents and increases safety of analyst’s work.

  8. A New Method for Fracturing Wells Reservoir Evaluation in Fractured Gas Reservoir

    Directory of Open Access Journals (Sweden)

    Jianchun Guo

    2014-01-01

    Full Text Available Natural fracture is a geological phenomenon widely distributed in tight formation, and fractured gas reservoir stimulation effect mainly depends on the communication of natural fractures. Therefore it is necessary to carry out the evaluation of this reservoir and to find out the optimal natural fractures development wells. By analyzing the interactions and nonlinear relationships of the parameters, it establishes three-level index system of reservoir evaluation and proposes a new method for gas well reservoir evaluation model in fractured gas reservoir on the basis of fuzzy logic theory and multilevel gray correlation. For this method, the Gaussian membership functions to quantify the degree of every factor in the decision-making system and the multilevel gray relation to determine the weight of each parameter on stimulation effect. Finally through fuzzy arithmetic operator between multilevel weights and fuzzy evaluation matrix, score, rank, the reservoir quality, and predicted production will be gotten. Result of this new method shows that the evaluation of the production coincidence rate reaches 80%, which provides a new way for fractured gas reservoir evaluation.

  9. Image Processing Methods Usable for Object Detection on the Chessboard

    Directory of Open Access Journals (Sweden)

    Beran Ladislav

    2016-01-01

    Full Text Available Image segmentation and object detection is challenging problem in many research. Although many algorithms for image segmentation have been invented, there is no simple algorithm for image segmentation and object detection. Our research is based on combination of several methods for object detection. The first method suitable for image segmentation and object detection is colour detection. This method is very simply, but there is problem with different colours. For this method it is necessary to have precisely determined colour of segmented object before all calculations. In many cases it is necessary to determine this colour manually. Alternative simply method is method based on background removal. This method is based on difference between reference image and detected image. In this paper several methods suitable for object detection are described. Thisresearch is focused on coloured object detection on chessboard. The results from this research with fusion of neural networks for user-computer game checkers will be applied.

  10. DIRECT DETECTION OF PRECURSORS OF GAS GIANTS FORMED BY GRAVITATIONAL INSTABILITY WITH THE ATACAMA LARGE MILLIMETER/SUBMILLIMETER ARRAY

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, Lucio [Center for Theoretical Astrophysics and Cosmology, Institute for Computational Science, University of Zurich, Winterthurerstrasse 190, CH-8057 Zürich (Switzerland); Peters, Thomas [Max-Planck-Institut für Astrophysik, Karl-Schwarzschild-Str. 1, D-85748 Garching (Germany); Pineda, Jaime E. [Max-Planck-Institut für extraterrestrische Physik, Giessenbachstrasse 1, D-85748 Garching (Germany); Wadsley James; Rogers, Patrick, E-mail: p.rogers@marianopolis.edu [Department of Physics and Astronomy, McMaster University, Hamilton, ON L8S 4M1 (Canada)

    2016-06-01

    Phases of gravitational instability are expected in the early phases of disk evolution, when the disk mass is still a substantial fraction of the mass of the star. Disk fragmentation into sub-stellar objects could occur in the cold exterior part of the disk. Direct detection of massive gaseous clumps on their way to collapse into gas giant planets would offer an unprecedented test of the disk instability model. Here we use state-of-the-art 3D radiation-hydro simulations of disks undergoing fragmentation into massive gas giants, post-processed with RADMC-3D to produce dust continuum emission maps. These are then fed into the Common Astronomy Software Applications (CASA) ALMA simulator. The synthetic maps show that both overdense spiral arms and actual clumps at different stages of collapse can be detected with the Atacama Large Millimeter/submillimeter Array (ALMA) in the full configuration at the distance of the Ophiuchus star forming region (125 pc). The detection of clumps is particularly effective at shorter wavelengths (690 GHz) combining two resolutions with multi-scale clean. Furthermore, we show that a flux-based estimate of the mass of a protoplanetary clump can be comparable to a factor of three higher than the gravitationally bound clump mass. The estimated mass depends on the assumed opacity, and on the gas temperature, which should be set using the input of radiation-hydro simulations. We conclude that ALMA has the capability to detect “smoking gun” systems that are a signpost of the disk instability model for gas giant planet formation.

  11. Detection and diagnosis of a natural gas dehydration plant by absorption with triethylene glycol, employing a artificial neural networks

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    The natural gas dehydration is a great importance operation in the gas and petroleum industry, It avoids operational problems associated with the water content, which appear frequently in the industrial facilities that use the natural gas as raw material or as work tool. Due to the presence of undesirable pollutants which may enter the plant with the wet natural gas current (lubricating, corrosion inhibitors, salts, and others), the equipment that constitutes the dehydration plants are capable to suffering operational faults as the heat exchangers fouling, foam formation in the absorber, glycol losses for dragging; trays, packings, valves and filters fouling; glycol degradation, inadequate temperatures of regeneration and others. The above mentioned faults often cannot be detected by the operators and engineers but up to the moment when a catastrophic damage occurs or when products are obtained out of specification, which causes big economic and time losses. By means of the application of artificial neural networks, there was achieved the detection and the effective diagnosis of faults, still in incipient state, in a gas dehydration plant. (author)

  12. Off-gas processing method in reprocessing plant

    International Nuclear Information System (INIS)

    Kobayashi, Yoshihiro; Seki, Eiji.

    1990-01-01

    Off-gases containing a radioactive Kr gas generated in a nuclear fuel reprocessing plant are at first sent to a Kr gas separator. Then, the radioactive Kr gas extracted there is introduced to a Kr gas fixing device. A pretreatment and a post-treatment are applied by using a non-radioactive clean inert gas except for the Kr gas as a purge gas. If the radioactive Kr gas is contained in the off-gases discharged from the Kr gas fixing device after applying the post-treatment, the off gases are returned to the Kr gas separator. Accordingly, in a case where the radioactive Kr gas is contained in the off-gases discharged from the Kr gas fixing device, it is not necessary to apply the fixing treatment to all of the off gases. In view of the above, increase of the amount of processing gases can be suppressed and the radioactive Kr gas can be fixed efficiently and economically. (I.N.)

  13. Alternative sorptive extraction method for gas chromatography determination of halogenated anisoles in water and wine samples

    Energy Technology Data Exchange (ETDEWEB)

    Montes, R. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Instituto de Investigacion y Analisis Alimentario, Universidad de Santiago de Compostela, Santiago de Compostela 15782 (Spain); Rodriguez, I. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Instituto de Investigacion y Analisis Alimentario, Universidad de Santiago de Compostela, Santiago de Compostela 15782 (Spain)], E-mail: qnisaac@usc.es; Rubi, E.; Bollain, M.H.; Cela, R. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Instituto de Investigacion y Analisis Alimentario, Universidad de Santiago de Compostela, Santiago de Compostela 15782 (Spain)

    2007-09-05

    An alternative sorptive microextraction method for the determination of five halogenated anisoles in water and wine matrices is proposed. Analytes were concentrated in an inexpensive and disposable piece of bulk polydimethylsiloxane (PDMS), desorbed with a small volume of organic solvent, and determined by gas chromatography with electron-capture detection (GC-ECD) or tandem mass spectrometry (GC-MS/MS). The influence of several factors on the efficiency of extraction and desorption steps was investigated in detail and the observed behaviour justified on the basis of thermodynamics and kinetics of the solid-phase microextraction technique. Under optimised conditions, analytes were first extracted in the headspace (HS) mode, at room temperature, for 2.5 h and then desorbed with 1 mL of n-pentane. This extract was further evaporated to 50 {mu}L. The overall extraction yield of the procedure ranged from 40 to 55% and the limits of quantification remained between 0.5 and 20 ng L{sup -1}, depending on the compound considered and the detection technique. Precision and linearity of the method were excellent for all species with both GC-ECD and GC-MS/MS detection. Matrix effects were evaluated with different water and wine samples; moreover, the suitability of the PDMS sorbent for storage of analytes, under different conditions, was demonstrated.

  14. Alternative sorptive extraction method for gas chromatography determination of halogenated anisoles in water and wine samples

    International Nuclear Information System (INIS)

    Montes, R.; Rodriguez, I.; Rubi, E.; Bollain, M.H.; Cela, R.

    2007-01-01

    An alternative sorptive microextraction method for the determination of five halogenated anisoles in water and wine matrices is proposed. Analytes were concentrated in an inexpensive and disposable piece of bulk polydimethylsiloxane (PDMS), desorbed with a small volume of organic solvent, and determined by gas chromatography with electron-capture detection (GC-ECD) or tandem mass spectrometry (GC-MS/MS). The influence of several factors on the efficiency of extraction and desorption steps was investigated in detail and the observed behaviour justified on the basis of thermodynamics and kinetics of the solid-phase microextraction technique. Under optimised conditions, analytes were first extracted in the headspace (HS) mode, at room temperature, for 2.5 h and then desorbed with 1 mL of n-pentane. This extract was further evaporated to 50 μL. The overall extraction yield of the procedure ranged from 40 to 55% and the limits of quantification remained between 0.5 and 20 ng L -1 , depending on the compound considered and the detection technique. Precision and linearity of the method were excellent for all species with both GC-ECD and GC-MS/MS detection. Matrix effects were evaluated with different water and wine samples; moreover, the suitability of the PDMS sorbent for storage of analytes, under different conditions, was demonstrated

  15. Method of separation of gas mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Berlin, M.A.; Potapov, V.F.; Potapova, M.S.

    1980-04-05

    Gas mixtures are separated in a rectification tower by repeated counterflow contact of the heated gas flow and cool condensate as the pressure drops in each stage of separation (StR) and when condensate is added from StR with lower pressure to the StR with higher pressure. In order to reduce energy consumption noncondensing gas in amounts of 5-15 percent by weight of the amount of incoming gases are added. Hydrocarbon or carbon dioxide gas can be used as the latter. Example. To separate natural gas of the Shatlyk deposit of composition, percent by mo1: C1 -- 94.960; C2 -- 4.260; C3 -- 0.200; C4 -- 0.08; C4+B -- 0.51. It is enriched with carbon dioxide gas in an amount of 10 percent by weight. Upon rectification of the enriched hydrocarbon mixture separation is achieved at lower pressures of the gas mixture and less cold. This leads to reduction of energy consumption by 10-12 percent.

  16. Detection methods for irradiated food

    International Nuclear Information System (INIS)

    Stevenson, M.H.

    1993-01-01

    The plenary lecture gives a brief historical review of the development of methods for the detection of food irradiation and defines the demands on such methods. The methods described in detail are as follows: 1) Physical methods: As examples of luminescence methods, thermoluminescence and chermoluminescence are mentioned; ESR spectroscopy is discussed in detail by means of individual examples (crustaceans, frutis and vegetables, spieces and herbs, nuts). 2) Chemical methods: Examples given for these are methods that make use of alterations in lipids through radiation (formation of long-chain hydrocarbons, formation of 2-alkyl butanones), respectively radiation-induced alterations in the DNA. 3) Microbiological methods. An extensive bibliography is appended. (VHE) [de

  17. Research on technology of online gas chromatograph for SF6 decomposition products

    Science.gov (United States)

    Li, L.; Fan, X. P.; Zhou, Y. Y.; Tang, N.; Zou, Z. L.; Liu, M. Z.; Huang, G. J.

    2017-12-01

    Sulfur hexafluoride (SF6) decomposition products were qualitatively and quantitatively analyzed by several gas chromatographs in the laboratory. Test conditions and methods were selected and optimized to minimize and eliminate the SF6’ influences on detection of other trace components. The effective separation and detection of selected characteristic gases were achieved. And by comparison among different types of gas chromatograph, it was found that GPTR-S101 can effectively separate and detect SF6 decomposition products and has best the best detection limit and sensitivity. On the basis of GPTR-S101, online gas chromatograph for SF6decomposition products (GPTR-S201) was developed. It lays the foundation for further online monitoring and diagnosis of SF6.

  18. Detection of fuel element failures at the gas cooled reactors

    International Nuclear Information System (INIS)

    Bremsak, P.; Ranzel, S.; Ogrin, R.; Pisanski, C.

    1964-01-01

    This paper describes the system for measuring the concentration of released Kr and Xe in the cooling gas. The system developed in the Jozef Stefan Institute is efficient and suitable for application The method is based on electrostatic collection of daughter elements from radioactive decay of Xe and Kr

  19. Radon measurements over a natural-gas contaminated aquifer

    International Nuclear Information System (INIS)

    Palacios, D.; Fusella, E.; Avila, Y.; Salas, J.; Teixeira, D.; Fernández, G.; Salas, A.; Sajo-Bohus, L.; Greaves, E.; Barros, H.; Bolívar, M.; Regalado, J.

    2013-01-01

    Radon and thoron concentrations in soil pores in a gas production region of the Anzoategui State, Venezuela, were determined by active and passive methods. In this region, water wells are contaminated by natural gas and gas leaks exist in the nearby river. Based on soil gas Radon data surface hydrocarbon seeps were identified. Radon and thoron concentration maps show anomalously high values near the river gas leaks decreasing in the direction of water wells where natural gas is also detected. The area where the highest concentrations of 222 Rn were detected seems to indicate the surface projection of the aquifer contaminated with natural gas. The Radon/Thoron ratio revealed a micro-localized anomaly, indicating the area where the gas comes from deep layers of the subsoil. The radon map determined by the passive method showed a marked positive anomaly around abandoned gas wells. The high anomalous Radon concentration localized near the trails of ascending gas bubbles at the river indicates the zone trough where natural gases are ascending with greater ease, associated with a deep geological fault, being this the main source of methane penetration into the aquifer. It is suggested that the source of the natural gas may be due to leaks at deep sites along the structure of some of the abandoned wells located at the North-East of the studied area. - Highlights: ► High Radon/Thoron ratios were localized near the natural-gas emanations in a river. ► Natural gases are ascending trough a deep geological fault. ► Apparently, the radon anomaly shows the site where natural gas enters the aquifer. ► Natural gas source may be related to leaks in the structure of abandoned gas wells

  20. Development and validation of a multi-residue method for the detection of a wide range of hormonal anabolic compounds in hair using gas chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    Rambaud, Lauriane; Monteau, Fabrice; Deceuninck, Yoann; Bichon, Emmanuelle; Andre, Francois; Le Bizec, Bruno

    2007-01-01

    The monitoring of anabolic steroid residues in hair is undoubtedly one of the most efficient strategies to demonstrate the long-term administration of these molecules in meat production animals. A multi-residue sample preparation procedure was developed and validated for 28 steroids. A 100 mg hair sample was grinded into powder and extracted at 50 deg. C with methanol. After acidic hydrolysis and extraction with ethyl acetate, phenolsteroids, such as estrogens, resorcyclic acid lactones and stilbens in one hand, are separated from androgens and progestagens in the other hand. Solid phase extractions were performed before applying a specific derivatisation for each compound sub-group. Detection and identification were achieved using gas chromatography-tandem mass spectrometry with acquisition in the selected reaction monitoring mode after electron ionisation. The method was validated according to the 2002/657/EC guideline. Decision limits (CCα) for main steroids were in the 0.1-10 μg kg -1 range

  1. Development and validation of a multi-residue method for the detection of a wide range of hormonal anabolic compounds in hair using gas chromatography-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Rambaud, Lauriane [LABERCA, Ecole Nationale Veterinaire de Nantes, Route de Gachet, BP50707, 44307 Nantes Cedex 3 (France); Monteau, Fabrice [LABERCA, Ecole Nationale Veterinaire de Nantes, Route de Gachet, BP50707, 44307 Nantes Cedex 3 (France); Deceuninck, Yoann [LABERCA, Ecole Nationale Veterinaire de Nantes, Route de Gachet, BP50707, 44307 Nantes Cedex 3 (France); Bichon, Emmanuelle [LABERCA, Ecole Nationale Veterinaire de Nantes, Route de Gachet, BP50707, 44307 Nantes Cedex 3 (France); Andre, Francois [LABERCA, Ecole Nationale Veterinaire de Nantes, Route de Gachet, BP50707, 44307 Nantes Cedex 3 (France); Le Bizec, Bruno [LABERCA, Ecole Nationale Veterinaire de Nantes, Route de Gachet, BP50707, 44307 Nantes Cedex 3 (France)]. E-mail: lebizec@vet-nantes.fr

    2007-03-14

    The monitoring of anabolic steroid residues in hair is undoubtedly one of the most efficient strategies to demonstrate the long-term administration of these molecules in meat production animals. A multi-residue sample preparation procedure was developed and validated for 28 steroids. A 100 mg hair sample was grinded into powder and extracted at 50 deg. C with methanol. After acidic hydrolysis and extraction with ethyl acetate, phenolsteroids, such as estrogens, resorcyclic acid lactones and stilbens in one hand, are separated from androgens and progestagens in the other hand. Solid phase extractions were performed before applying a specific derivatisation for each compound sub-group. Detection and identification were achieved using gas chromatography-tandem mass spectrometry with acquisition in the selected reaction monitoring mode after electron ionisation. The method was validated according to the 2002/657/EC guideline. Decision limits (CC{alpha}) for main steroids were in the 0.1-10 {mu}g kg{sup -1} range.

  2. DEVELOPMENT OF NOVEL CERAMIC NANOFILM-FIBER INTEGRATED OPTICAL SENSORS FOR RAPID DETECTION OF COAL DERIVED SYNTHESIS GAS

    Energy Technology Data Exchange (ETDEWEB)

    Junhang Dong; Hai Xiao; Xiling Tang; Hongmin Jiang; Kurtis Remmel; Amardeep Kaur

    2012-09-30

    The overall goal of this project is to conduct fundamental studies on advanced ceramic materials and fiber optic devices for developing new types of high temperature (>500{degree}C) fiber optic chemical sensors (FOCS) for monitoring fossil (mainly coal) and biomass derived gases in power plants. The primary technical objective is to investigate and demonstrate the nanocrystalline doped-ceramic thin film enabled FOCS that possess desired stability, sensitivity and selectivity for in-situ, rapid gas detection in the syngas streams from gasification and combustion flue gases. This report summarizes research works of two integrated parts: (1) development of metal oxide solid thin films as sensing materials for detection and measurement of important gas components relevant to the coal- and biomass-derived syngas and combustion gas streams at high temperatures; and (2) development of fiber optic devices that are potentially useful for constructing FOCS in combination with the solid oxide thin films identified in this program.

  3. Estimation of internal heat transfer coefficients and detection of rib positions in gas turbine blades from transient surface temperature measurements

    International Nuclear Information System (INIS)

    Heidrich, P; Wolfersdorf, J v; Schmidt, S; Schnieder, M

    2008-01-01

    This paper describes a non-invasive, non-destructive, transient inverse measurement technique that allows one to determine internal heat transfer coefficients and rib positions of real gas turbine blades from outer surface temperature measurements after a sudden flow heating. The determination of internal heat transfer coefficients is important during the design process to adjust local heat transfer to spatial thermal load. The detection of rib positions is important during production to fulfill design and quality requirements. For the analysis the one-dimensional transient heat transfer problem inside of the turbine blade's wall was solved. This solution was combined with the Levenberg-Marquardt method to estimate the unknown boundary condition by an inverse technique. The method was tested with artificial data to determine uncertainties with positive results. Then experimental testing with a reference model was carried out. Based on the results, it is concluded that the presented inverse technique could be used to determine internal heat transfer coefficients and to detect rib positions of real turbine blades.

  4. Cycle-by-cycle exhaust temperature monitoring for detection of misfiring and combustion instability in reciprocating natural gas engines

    Energy Technology Data Exchange (ETDEWEB)

    Gardiner, D.P. [Nexum Research Corp., Kingston, ON (Canada); Bardon, M.F. [Royal Military Coll. of Canada, Kingston, ON (Canada). Dept. of Mechanical Engineering

    2007-07-01

    The effectiveness of a cycle-by-cycle exhaust temperature monitoring system on engines operating at or near their fully rate load capacity was examined. Tests were conducted on stationary industrial natural gas engines. The study evaluated the monitoring system's ability to detect isolated single misfires, as well as combustion instability during misfire-free operations when the air/fuel ratio of the engine was adjusted to progressively lower settings. The combustion instability level of the engines was quantified by determining the relative variability of the groups of consecutive cycles. The coefficient of variation of indicated mean effective pressure (COV of IMEP) was used to examine cyclic variability. A combustion instability index was used to quantify cyclic variability with cycle-by-cycle exhaust temperature monitoring. Two engines were tested, notably a Cummins QSK 19G turbocharged natural gas engine; and a Waukesha VHP L5790G industrial natural gas engine. The tests demonstrated that cycle-by-cycle exhaust temperature monitoring system was capable of detecting misfiring and combustion instabilities in natural gas engines. 6 refs., 9 figs.

  5. A novel method for producing multiple ionization of noble gas

    International Nuclear Information System (INIS)

    Wang Li; Li Haiyang; Dai Dongxu; Bai Jiling; Lu Richang

    1997-01-01

    We introduce a novel method for producing multiple ionization of He, Ne, Ar, Kr and Xe. A nanosecond pulsed electron beam with large number density, which could be energy-controlled, was produced by incidence a focused 308 nm laser beam onto a stainless steel grid. On Time-of-Flight Mass Spectrometer, using this electron beam, we obtained multiple ionization of noble gas He, Ne, Ar and Xe. Time of fight mass spectra of these ions were given out. These ions were supposed to be produced by step by step ionization of the gas atoms by electron beam impact. This method may be used as a ideal soft ionizing point ion source in Time of Flight Mass Spectrometer

  6. Method of collecting helium cover gas for heavy water moderated reactor

    International Nuclear Information System (INIS)

    Miyamoto, Keiji; Ueda, Hiroshi.

    1981-01-01

    Purpose: To reduce the systematic facility cost in a heavy water moderated reactor by contriving the simplification of a helium cover gas collecting intake system. Method: A detachable low pressure metal tank and a neoprene balloon are prepared for a vacuum pump in a permanent vacuum drying facility. When all of the helium cover gas is collected from a heavy water moderated reactor, a large capacity of neoprene balloon capable of temporarily storing it under low pressure is connected to the exhaust of the vacuum pump. On the other hand, while the reactor is operating, a suitable amount of the low pressure tank or neoprene balloon is connected to the exhaust side of the pump, thereby regulating the pressure of the helium cover gas. When refeeding the cover gas, the balloon, with a large capacity for collecting and storing the cover gas is connected to the intake side of the pump. Thus, the pressure regulation, collection of all of the cover gas and refeeding of the cover gas can be conducted without using a high discharge pump and high pressure tank. (Kamimura, M.)

  7. Intercomparisons to evaluate the suitability of gaschromatographic, electron-spin-resonance spectrometric and thermoluminescence methods to detect irradiated foods in routine control

    International Nuclear Information System (INIS)

    Schreiber, G.A.; Helle, N.; Schulzki, G.; Spiegelberg, A.; Linke, B.; Wagner, U.; Boegl, K.W.

    1993-01-01

    The results of four different intercomparisons to detect irradiated fish and chicken meat containing bones, chicken-, pork-, and beef-meat without bones, spices, herbs as well as spice- and herb mixtures, various fruit and vegetables as well as pistachio nuts using gas chromatographic methods, electron-spin resonance spectroscopy or thermoluminescence analyses are reported. (author)

  8. Method of gas separation

    International Nuclear Information System (INIS)

    Weltner, W.W.

    1980-01-01

    In order to separate a mixture of gases having widely different partial pressures at a given temperature, a chamber is employed. A batch of gas mixture is passed into the chamber. The walls of the chamber are cooled by a refrigerant which passes through coils in heat exchange relationship with the walls. By this means the temperature of the chamber is cooled to a temperature (and held at such temperature until equilibrium is reached) at which all the components of the gas mixture have changed state, at least one being solidified and at least one liquefied. The liquid constituents are removed first. Then the chamber is warmed to facilitate removal of the previously solidified constituents. In an example, the gas mixture comprises nitrogen, argon, krypton and xenon, and the walls of the chamber are cooled by liquid nitrogen, the argon and nitrogen being liquefied and the xenon and krypton being solidified. (author)

  9. Detection of cold gas releases in space via low energy neutral atom imaging

    International Nuclear Information System (INIS)

    McComas, D.J.; Funsten, H.O.; Moore, K.R.; Scime, E.E.; Thomsen, M.F.

    1993-01-01

    Low energy neutral atoms (LENAs) are produced in space plasmas by charge exchange between the ambient magnetospheric plasma ions and cold neutral atoms. Under normal conditions these cold neutrals come from the terrestrial geocorona, a shroud of few-eV hydrogen atoms surrounding the Earth. As a consequence of this charge exchange, it has become possible to remotely image many regions of the magnetosphere for the first time utilizing recently developed LENA imaging technology. In addition to the natural hydrogen geocorona, conventional explosions and maneuvering thruster firings can also introduce large amounts of cold gas into the space environment. In this paper the authors examine whether such potentially clandestine activities could also be remotely observed for the first time via LENA imaging. First, they examine the fluxes of LENAs produced in the space environment from a conventional explosion. Then they review the present state of the art in the emerging field of LENA detection and imaging. Recent work has shown that LENAs can be imaged by first converting the neutrals to ions with ultra-thin (10s of angstrom) foils and then electrostatically analyzing these newly created ions to reject the large (> 10 10 cm -2 s -1 ) UV background to which the low energy detectors are sensitive. They conclude that the sensitivities for present LENA imager designs may be just adequate for detecting some man-made releases. With additional improvements in LENA detection capabilities, this technique could become an important new method for monitoring for conventional explosions, as well as other man-made neutral releases, in the space environment

  10. Gas dispersion concentration of trace inorganic contaminants from fuel gas and analysis using head-column field-amplified sample stacking capillary electrophoresis.

    Science.gov (United States)

    Yang, Jianmin; Li, Hai-Fang; Li, Meilan; Lin, Jin-Ming

    2012-08-21

    The presence of inorganic elements in fuel gas generally accelerates the corrosion and depletion of materials used in the fuel gas industry, and even leads to serious accidents. For identification of existing trace inorganic contaminants in fuel gas in a portable way, a highly efficient gas-liquid sampling collection system based on gas dispersion concentration is introduced in this work. Using the constructed dual path gas-liquid collection setup, inorganic cations and anions were simultaneously collected from real liquefied petroleum gas (LPG) and analyzed by capillary electrophoresis (CE) with indirect UV absorbance detection. The head-column field-amplified sample stacking technique was applied to improve the detection limits to 2-25 ng mL(-1). The developed collection and analytical methods have successfully determined existing inorganic contaminants in a real LPG sample in the range of 4.59-138.69 μg m(-3). The recoveries of cations and anions with spiked LPG samples were between 83.98 and 105.63%, and the relative standard deviations (RSDs) were less than 7.19%.

  11. Performance evaluation of a thermal desorption/gas chromatographic/mass spectrometric method for the characterization of waste tank headspace samples

    International Nuclear Information System (INIS)

    Ma, C.Y.; Skeen, J.T.; Dindal, A.B.; Bayne, C.K.; Jenkins, R.A.

    1997-01-01

    A thermal desorption/gas chromatography/mass spectrometry (TD/GC/MS) method was validated for the determination of volatile organic compounds collected on carbonaceous triple sorbent traps and applied to characterize samples of headspace gases collected from underground nuclear waste storage tanks at the U.S. Department of Energy's Hanford site, in Richland, WA. Method validation used vapor-phase standards generated from 25 target analytes, including alkanes, alkyl alcohols, alkyl ketones, alkylated aromatics, and alkyl nitriles. The target analytes represent a group of compounds identified in one of the most problematic tanks. TD/GC/MS was carried out with modified injectors. Performance was characterized based on desorption efficiency, reproducibility, stability, and linearity of the calibration, method detection limits, preanalytical holding time, and quality control limits for surrogate standard recoveries. Desorption efficiencies were all greater than 82%, and the majority of the analytes (23 out of 25) had reproducibility values less than 24% near the method detection levels. The method was applied to the analysis of a total of 305 samples collected from the headspaces of 48 underground waste storge tanks. Quality control procedures were implemented to monitor sampling and TD/GC/MS method. 33 refs., 2 figs., 4 tabs

  12. Measurement of polychlorinated biphenyls in solid waste such as transformer insulation paper by supercritical fluid extraction and gas chromatography electron capture detection.

    Science.gov (United States)

    Chikushi, Hiroaki; Fujii, Yuka; Toda, Kei

    2012-09-21

    In this work, a method for measuring polychlorinated biphenyls (PCBs) in contaminated solid waste was investigated. This waste includes paper that is used in electric transformers to insulate electric components. The PCBs in paper sample were extracted by supercritical fluid extraction and analyzed by gas chromatography-electron capture detection. The recoveries with this method (84-101%) were much higher than those with conventional water extraction (0.08-14%), and were comparable to those with conventional organic solvent extraction. Limit of detection was 0.0074 mg kg(-1) and measurable up to 2.5 mg kg(-1) for 0.5 g of paper sample. Data for real insulation paper by the proposed method agreed well with those by the conventional organic solvent extraction. Extraction from wood and concrete was also investigated and good performance was obtained as well as for paper samples. The supercritical fluid extraction is simpler, faster, and greener than conventional organic solvent extraction. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Detection methods for mycotoxins in cereal grains and cereal products

    Directory of Open Access Journals (Sweden)

    Pascale Michelangelo N.

    2009-01-01

    Full Text Available Analytical methods for mycotoxins in cereals and cereal-based products require three major steps, including extraction, clean-up (to eliminate interferences from the extract and concentrate the analyte, and detection/determination of the toxin (by using suitable analytical instruments/technologies. Clean-up is essential for the analysis of mycotoxins at trace levels, and involves the use of solid phase extraction and multifunctional (e.g. MycoSep® or immunoaffinity columns. Different chromatographic methods are commonly used for quantitative determination of mycotoxins, including gas-chromatography (GC coupled with electron capture, flame ionization or mass spectrometry (MS detectors (mainly for type-A trichothecenes, and high-performance liquid chromatography (HPLC coupled with ultraviolet, diode array, fluorescence or MS detectors. The choice of method depends on the matrix and the mycotoxin to be analyzed. Liquid chromatography-tandem mass spectrometry (LC-MS/MS is spreading rapidly as a promising technique for simultaneous screening, identification and quantitative determination of a large number of mycotoxins. In addition, commercial immunometric assays, such as enzyme-linked immunosorbent assays (ELISA, are frequently used for screening purposes as well. Recently, a variety of emerging methods have been proposed for the analysis of mycotoxins in cereals based on novel technologies, including immunochromatography (i.e. lateral flow devices, fluorescence polarization immunoassays (FPIA, infrared spectroscopy (FT-NIR, molecularly imprinted polymers (MIPs and optical biosensors.

  14. Method to make accurate concentration and isotopic measurements for small gas samples

    Science.gov (United States)

    Palmer, M. R.; Wahl, E.; Cunningham, K. L.

    2013-12-01

    Carbon isotopic ratio measurements of CO2 and CH4 provide valuable insight into carbon cycle processes. However, many of these studies, like soil gas, soil flux, and water head space experiments, provide very small gas sample volumes, too small for direct measurement by current constant-flow Cavity Ring-Down (CRDS) isotopic analyzers. Previously, we addressed this issue by developing a sample introduction module which enabled the isotopic ratio measurement of 40ml samples or smaller. However, the system, called the Small Sample Isotope Module (SSIM), does dilute the sample during the delivery with inert carrier gas which causes a ~5% reduction in concentration. The isotopic ratio measurements are not affected by this small dilution, but researchers are naturally interested accurate concentration measurements. We present the accuracy and precision of a new method of using this delivery module which we call 'double injection.' Two portions of the 40ml of the sample (20ml each) are introduced to the analyzer, the first injection of which flushes out the diluting gas and the second injection is measured. The accuracy of this new method is demonstrated by comparing the concentration and isotopic ratio measurements for a gas sampled directly and that same gas measured through the SSIM. The data show that the CO2 concentration measurements were the same within instrument precision. The isotopic ratio precision (1σ) of repeated measurements was 0.16 permil for CO2 and 1.15 permil for CH4 at ambient concentrations. This new method provides a significant enhancement in the information provided by small samples.

  15. Novel Method For Low-Rate Ddos Attack Detection

    Science.gov (United States)

    Chistokhodova, A. A.; Sidorov, I. D.

    2018-05-01

    The relevance of the work is associated with an increasing number of advanced types of DDoS attacks, in particular, low-rate HTTP-flood. Last year, the power and complexity of such attacks increased significantly. The article is devoted to the analysis of DDoS attacks detecting methods and their modifications with the purpose of increasing the accuracy of DDoS attack detection. The article details low-rate attacks features in comparison with conventional DDoS attacks. During the analysis, significant shortcomings of the available method for detecting low-rate DDoS attacks were found. Thus, the result of the study is an informal description of a new method for detecting low-rate denial-of-service attacks. The architecture of the stand for approbation of the method is developed. At the current stage of the study, it is possible to improve the efficiency of an already existing method by using a classifier with memory, as well as additional information.

  16. A Stirling engine analysis method based upon moving gas nodes

    Science.gov (United States)

    Martini, W. R.

    1986-01-01

    A Lagrangian nodal analysis method for Stirling engines (SEs) is described, validated, and applied to a conventional SE and an isothermalized SE (with fins in the hot and cold spaces). The analysis employs a constant-mass gas node (which moves with respect to the solid nodes during each time step) instead of the fixed gas nodes of Eulerian analysis. The isothermalized SE is found to have efficiency only slightly greater than that of a conventional SE.

  17. Method and system for gas flow mitigation of molecular contamination of optics

    Science.gov (United States)

    Delgado, Gildardo; Johnson, Terry; Arienti, Marco; Harb, Salam; Klebanoff, Lennie; Garcia, Rudy; Tahmassebpur, Mohammed; Scott, Sarah

    2018-01-23

    A computer-implemented method for determining an optimized purge gas flow in a semi-conductor inspection metrology or lithography apparatus, comprising receiving a permissible contaminant mole fraction, a contaminant outgassing flow rate associated with a contaminant, a contaminant mass diffusivity, an outgassing surface length, a pressure, a temperature, a channel height, and a molecular weight of a purge gas, calculating a flow factor based on the permissible contaminant mole fraction, the contaminant outgassing flow rate, the channel height, and the outgassing surface length, comparing the flow factor to a predefined maximum flow factor value, calculating a minimum purge gas velocity and a purge gas mass flow rate from the flow factor, the contaminant mass diffusivity, the pressure, the temperature, and the molecular weight of the purge gas, and introducing the purge gas into the semi-conductor inspection metrology or lithography apparatus with the minimum purge gas velocity and the purge gas flow rate.

  18. A Novel Unscheduled Islanding Detection Method for Microgrid

    Directory of Open Access Journals (Sweden)

    Li Hui

    2018-01-01

    Full Text Available Microgrid with its intelligent and flexible control characteristics conform to the trend of sustainable development of electricity, and when the microgrid in the unplanned island state, the successful detection of the island is a prerequisite, energy storage inverter as the key equipment in the microgrid system, island protection is one of the necessary functions. In this paper, an improved islanding detection method based on active frequency drift and q-axis reactive power perturbation is proposed. The method has the advantages of faster detection speed and minor influence on power quality, which makes the energy storage inverter with better output power quality when it works on grid-connected state, and can be detected the islanding state quickly from grid-connected mode to islanded mode. Finally, the validity and superiority of the improved island detection method are verified by simulation experiments.

  19. Homogeneous liquid-liquid extraction (HoLLE) via flotation combined with gas chromatography-flame ionization detection as a very simple, rapid and sensitive method for the determination of fenitrothion in water samples.

    Science.gov (United States)

    Mashayekhi, Hossein Ali

    2013-01-01

    Homogeneous liquid-liquid extraction via flotation assistance (HoLLE-FA) and gas chromatography-flame ionization detection (GC-FID) was presented for the extraction and determination of fenitrothion in water samples. In this work, a rapid, simple and efficient HoLLE-FA method was developed based on applying low-density organic solvents without employing centrifugation. A special extraction cell was designed to facilitate the collection of low-density solvent extraction in the determination of fenitrothion in water samples. The water sample solution was added into an extraction cell that contained an appropriate mixture of extraction and homogeneous solvents. By using air flotation, the organic solvent was collected at the conical part of the designed cell. Under the optimum conditions, the method performance was studied in terms of the linear dynamic range (LDR from 1.0 up to 100 μg L⁻¹), linearity (r² > 0.998), and precision (repeatability extraction and determination of fenitrothion in three different water samples.

  20. Detecting Android Malwares with High-Efficient Hybrid Analyzing Methods

    Directory of Open Access Journals (Sweden)

    Yu Liu

    2018-01-01

    Full Text Available In order to tackle the security issues caused by malwares of Android OS, we proposed a high-efficient hybrid-detecting scheme for Android malwares. Our scheme employed different analyzing methods (static and dynamic methods to construct a flexible detecting scheme. In this paper, we proposed some detecting techniques such as Com+ feature based on traditional Permission and API call features to improve the performance of static detection. The collapsing issue of traditional function call graph-based malware detection was also avoided, as we adopted feature selection and clustering method to unify function call graph features of various dimensions into same dimension. In order to verify the performance of our scheme, we built an open-access malware dataset in our experiments. The experimental results showed that the suggested scheme achieved high malware-detecting accuracy, and the scheme could be used to establish Android malware-detecting cloud services, which can automatically adopt high-efficiency analyzing methods according to the properties of the Android applications.

  1. Numerical Method based on SIMPLE Algorithm for a Two-Phase Flow with Non-condensable Gas

    International Nuclear Information System (INIS)

    Kim, Jong Tae

    2009-08-01

    In this study, a numerical method based on SIMPLE algorithm for a two-phase flow with non-condensable gas has been developed in order to simulate thermal hydraulics in a containment of a nuclear power plant. As governing equations, it adopts a two-fluid three-field model for the two-phase flows. The three fields include gas, drops, and continuous liquid. The gas field can contains vapor and non-condensable gases such as air and hydrogen. In order to resolve mixing phenomena of gas species, gas transport equations for each species base on the gas mass fractions are solved with gas phase governing equations such as mass, momentum and energy equations. Methods to evaluate the properties of the gas species were implemented in the code. They are constant or polynomial function based a user input and a property library from Chemkin and JANAF table for gas specific heat. Properties for the gas mixture which are dependent on mole fractions of the gas species were evaluated by a mix rule

  2. Cancer Detection and Diagnosis Methods - Annual Plan

    Science.gov (United States)

    Early cancer detection is a proven life-saving strategy. Learn about the research opportunities NCI supports, including liquid biopsies and other less-invasive methods, for detecting early cancers and precancerous growths.

  3. Method for combined removal of mercury and nitrogen oxides from off-gas streams

    Science.gov (United States)

    Mendelsohn, Marshall H [Downers Grove, IL; Livengood, C David [Lockport, IL

    2006-10-10

    A method for removing elemental Hg and nitric oxide simultaneously from a gas stream is provided whereby the gas stream is reacted with gaseous chlorinated compound to convert the elemental mercury to soluble mercury compounds and the nitric oxide to nitrogen dioxide. The method works to remove either mercury or nitrogen oxide in the absence or presence of each other.

  4. Optical system for CO and NO gas detection in the exhaust manifold of combustion engines

    International Nuclear Information System (INIS)

    Mello, M.; De Vittorio, M.; Passaseo, A.; Lomascolo, M.; De Risi, A.

    2007-01-01

    The experimental characterization of an innovative optical system for detection of carbon monoxide (CO) and nitride oxide (NO) in the exhaust manifold of otto and diesel engines is reported. A photodetector based on gallium nitride (GaN) and an UV light source are integrated in a chamber of analysis and form the detection system. The UV light source, consisting of a spark produced by an arc discharge, induces electronic transitions in the gas molecules flowing between the light source and the GaN photodetector. The transitions modify the fraction of light in the UV spectral region which is detected by the GaN photodetector, as a function of the species concentration. By means of its structural properties, gallium nitride (GaN) allows to operate at high temperature and high speed and to work in situ in the exhaust manifold of combustion engines at temperatures as high as 600 o C, at which the deposited organic residuals on the detector can be oxidized. This assures a clear surface necessary for a real time optical measurement of the species concentration to be used for a closed loop control of the fuel injection process. The system was applied to the detection of CO and NO with concentration between 0% and 2% in a buffer of pure nitrogen gas, showing an increase in the measured photocurrent as a function of the above gases

  5. A new method research of monitoring low concentration NO and SO2 mixed gas

    Science.gov (United States)

    Bo, Peng; Gao, Chao; Guo, Yongcai; Chen, Fang

    2018-01-01

    In order to reduce the pollution of the environment, China has implemented a new ultra-low emission control regulations for polluting gas, requiring new coal-fired power plant emissions SO2 less than 30ppm, NO less than 75ppm, NO2 less than 50ppm, Monitoring low concentration of NO and SO2 mixed gases , DOAS technology facing new challenges, SO2 absorb significantly weaken at the original absorption peak, what more the SNR is very low, it is difficult to extract the characteristic signal, and thus cannot obtain its concentration. So it cannot separate the signal of NO from the mixed gas at the wavelength of 200 230nm through the law of spectral superposition, it cannot calculate the concentration of NO. The classical DOAS technology cannot meet the needs of monitoring. In this paper, we found another absorption spectrum segment of SO2, the SNR is 10 times higher than before, Will not be affected by NO, can calculate the concentration of SO2 accurately, A new method of segmentation and demagnetization separation technology of spectral signals is proposed, which achieves the monitoring the low concentration mixed gas accurately. This function cannot be achieved by the classical DOAS. Detection limit of this method is 0.1ppm per meter which is higher than before, The relative error below 5% when the concentration between 0 5ppm, the concentration of NO between 6 75ppm and SO2 between 6 30ppm the relative error below 1.5%, it has made a great breakthrough In the low concentration of NO and SO2 monitoring. It has great scientific significance and reference value for the development of coal-fired power plant emission control, atmospheric environmental monitoring and high-precision on-line instrumentation.

  6. Detection method of internal leakage from valve using acoustic method

    International Nuclear Information System (INIS)

    Kumagai, Horomichi

    1990-01-01

    The purpose of this study is to estimate the availability of acoustic method for detecting the internal leakage of valves at power plants. Experiments have been carried out on the characteristics of acoustic noise caused by the leak simulated flow. From the experimental results, the mechanism of the acoustic noisegenerated from flow, the relation between acoustic intensity and leak flow velocity, and the characteristics of the acoustic frequency spectrum were clarified. The acoustic method was applied to valves at site, and the background noises were measured in abnormal plant conditions. When the background level is higher than the acoustic signal, the difference between the background noise frequency spectrum and the acoustic signal spectrum provide a very useful leak detection method. (author)

  7. A new in-situ method to determine the apparent gas diffusion coefficient of soils

    Science.gov (United States)

    Laemmel, Thomas; Paulus, Sinikka; Schack-Kirchner, Helmer; Maier, Martin

    2015-04-01

    Soil aeration is an important factor for the biological activity in the soil and soil respiration. Generally, gas exchange between soil and atmosphere is assumed to be governed by diffusion and Fick's Law is used to describe the fluxes in the soil. The "apparent soil gas diffusion coefficient" represents the proportional factor between the flux and the gas concentration gradient in the soil and reflects the ability of the soil to "transport passively" gases through the soil. One common way to determine this coefficient is to take core samples in the field and determine it in the lab. Unfortunately this method is destructive and needs laborious field work and can only reflect a small fraction of the whole soil. As a consequence insecurity about the resulting effective diffusivity on the profile scale must remain. We developed a new in-situ method using new gas sampling device, tracer gas and inverse soil gas modelling. The gas sampling device contains several sampling depths and can be easily installed into vertical holes of an auger, which allows for fast installation of the system. At the lower end of the device inert tracer gas is injected continuously. The tracer gas diffuses into the surrounding soil. The resulting distribution of the tracer gas concentrations is used to deduce the diffusivity profile of the soil. For Finite Element Modeling of the gas sampling device/soil system the program COMSOL is used. We will present the results of a field campaign comparing the new in-situ method with lab measurements on soil cores. The new sampling pole has several interesting advantages: it can be used in-situ and over a long time; so it allows following modifications of diffusion coefficients in interaction with rain but also vegetation cycle and wind.

  8. A Sub-ppm Acetone Gas Sensor for Diabetes Detection Using 10 nm Thick Ultrathin InN FETs

    Science.gov (United States)

    Kao, Kun-Wei; Hsu, Ming-Che; Chang, Yuh-Hwa; Gwo, Shangjr; Yeh, J. Andrew

    2012-01-01

    An indium nitride (InN) gas sensor of 10 nm in thickness has achieved detection limit of 0.4 ppm acetone. The sensor has a size of 1 mm by 2.5 mm, while its sensing area is 0.25 mm by 2 mm. Detection of such a low acetone concentration in exhaled breath could enable early diagnosis of diabetes for portable physiological applications. The ultrathin InN epilayer extensively enhances sensing sensitivity due to its strong electron accumulation on roughly 5–10 nm deep layers from the surface. Platinum as catalyst can increase output current signals by 2.5-fold (94 vs. 37.5 μA) as well as reduce response time by 8.4-fold (150 vs. 1,260 s) in comparison with bare InN. More, the effect of 3% oxygen consumption due to breath inhalation and exhalation on 2.4 ppm acetone gas detection was investigated, indicating that such an acetone concentration can be analyzed in air. PMID:22969342

  9. Method of detecting failed fuels

    International Nuclear Information System (INIS)

    Ishizaki, Hideaki; Suzumura, Takeshi.

    1982-01-01

    Purpose: To enable the settlement of the temperature of an adequate filling high temperature pure water by detecting the outlet temperature of a high temperature pure water filling tube to a fuel assembly to control the heating of the pure water and detecting the failed fuel due to the sampling of the pure water. Method: A temperature sensor is provided at a water tube connected to a sipping cap for filling high temperature pure water to detect the temperature of the high temperature pure water at the outlet of the tube, and the temperature is confirmed by a temperature indicator. A heater is controlled on the basis of this confirmation, an adequate high temperature pure water is filled in the fuel assembly, and the pure water is replaced with coolant. Then, it is sampled to settle the adequate temperature of the high temperature coolant used for detecting the failure of the fuel assembly. As a result, the sipping effect does not decrease, and the failed fuel can be precisely detected. (Yoshihara, H.)

  10. Rapid gas chromatography with flame photometric detection of multiple organophosphorus pesticides in Salvia miltiorrhizae after ultrasonication assisted one-step extraction.

    Science.gov (United States)

    Zhang, Shanshan; Liu, Xiaofei; Qin, Jia'an; Yang, Meihua; Zhao, Hongzheng; Wang, Yong; Guo, Weiying; Ma, Zhijie; Kong, Weijun

    2017-11-15

    A simple and rapid gas chromatography-flame photometric detection (GC-FPD) method was developed for the determination of 12 organophosphorus pesticides (OPPs) in Salvia miltiorrhizae by using ultrasonication assisted one-step extraction (USAE) without any clean-up steps. Some crucial parameters such as type of extraction solvent were optimized to improve the method performance for trace analysis. Any clean-up steps were negligent as no interferences were detected in the GC-FPD chromatograms for sensitive detection. Under the optimized conditions, limits of detection (LODs) and quantitation (LOQs) for all pesticides were in the range of 0.001-0.002mg/kg and 0.002-0.01mg/kg and 0.002-0.01mg/kg, respectively, which were all below the regulatory maximum residue limits suggested. RSDs for method precision (intra- and inter-day variations) were lower than 6.8% in approval with international regulations. Average recovery rates for all pesticides at three fortification levels (0.5, 1.0 and 5.0mg/kg) were in the range of 71.2-101.0% with relative standard deviations (RSDs) pesticide (dimethoate) out of the 12 targets was simultaneously detected in four samples at concentrations of 0.016-0.02mg/kg. Dichlorvos and omethoate were found in the same sample from Sichuan province at 0.004 and 0.027mg/kg, respectively. Malathion and monocrotophos were determined in the other two samples at 0.014 and 0.028mg/kg, respectively. All the positive samples were confirmed by LC-MS/MS. The simple, reliable and rapid USAE-GC-FPD method with many advantages over traditional techniques would be preferred for trace analysis of multiple pesticides in more complex matrices. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Increasing the selectivity and sensitivity of gas sensors for the detection of explosives

    Science.gov (United States)

    Mallin, Daniel

    Over the past decade, the use of improvised explosive devices (IEDs) has increased, domestically and internationally, highlighting a growing need for a method to quickly and reliably detect explosive devices in both military and civilian environments before the explosive can cause damage. Conventional techniques have been successful in explosive detection, however they typically suffer from enormous costs in capital equipment and maintenance, costs in energy consumption, sampling, operational related expenses, and lack of continuous and real-time monitoring. The goal was thus to produce an inexpensive, portable sensor that continuously monitors the environment, quickly detects the presence of explosive compounds and alerts the user. In 2012, here at URI, a sensor design was proposed for the detection of triacetone triperoxide (TATP). The design entailed a thermodynamic gas sensor that measures the heat of decomposition between trace TATP vapor and a metal oxide catalyst film. The sensor was able to detect TATP vapor at the part per million level (ppm) and showed great promise for eventual commercial use, however, the sensor lacked selectivity. Thus, the specific objective of this work was to take the original sensor design proposed in 2012 and to make several key improvements to advance the sensor towards commercialization. It was demonstrated that a sensor can be engineered to detect TATP and ignore the effects of interferent H2O2 molecules by doping SnO2 films with varying amounts of Pd. Compared with a pure SnO2 catalyst, a SnO2, film doped with 8 wt. % Pd had the highest selectivity between TATP and H2O2. Also, at 12 wt. % Pd, the response to TATP and H2O2 was enhanced, indicating that sensitivity, not only selectivity, can be increased by modifying the composition of the catalyst. An orthogonal detection system was demonstrated. The platform consists of two independent sensing mechanisms, one thermodynamic and one conductometric, which take measurements from

  12. System and Method for Multi-Wavelength Optical Signal Detection

    Science.gov (United States)

    McGlone, Thomas D. (Inventor)

    2017-01-01

    The system and method for multi-wavelength optical signal detection enables the detection of optical signal levels significantly below those processed at the discrete circuit level by the use of mixed-signal processing methods implemented with integrated circuit technologies. The present invention is configured to detect and process small signals, which enables the reduction of the optical power required to stimulate detection networks, and lowers the required laser power to make specific measurements. The present invention provides an adaptation of active pixel networks combined with mixed-signal processing methods to provide an integer representation of the received signal as an output. The present invention also provides multi-wavelength laser detection circuits for use in various systems, such as a differential absorption light detection and ranging system.

  13. Steam leak detection method in pipeline using histogram analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Se Oh; Jeon, Hyeong Seop; Son, Ki Sung; Chae, Gyung Sun [Saean Engineering Corp, Seoul (Korea, Republic of); Park, Jong Won [Dept. of Information Communications Engineering, Chungnam NationalUnversity, Daejeon (Korea, Republic of)

    2015-10-15

    Leak detection in a pipeline usually involves acoustic emission sensors such as contact type sensors. These contact type sensors pose difficulties for installation and cannot operate in areas having high temperature and radiation. Therefore, recently, many researchers have studied the leak detection phenomenon by using a camera. Leak detection by using a camera has the advantages of long distance monitoring and wide area surveillance. However, the conventional leak detection method by using difference images often mistakes the vibration of a structure for a leak. In this paper, we propose a method for steam leakage detection by using the moving average of difference images and histogram analysis. The proposed method can separate the leakage and the vibration of a structure. The working performance of the proposed method is verified by comparing with experimental results.

  14. A review on automated pavement distress detection methods

    NARCIS (Netherlands)

    Coenen, Tom B.J.; Golroo, Amir

    2017-01-01

    In recent years, extensive research has been conducted on pavement distress detection. A large part of these studies applied automated methods to capture different distresses. In this paper, a literature review on the distresses and related detection methods are presented. This review also includes

  15. Ion transport membrane reactor systems and methods for producing synthesis gas

    Science.gov (United States)

    Repasky, John Michael

    2015-05-12

    Embodiments of the present invention provide cost-effective systems and methods for producing a synthesis gas product using a steam reformer system and an ion transport membrane (ITM) reactor having multiple stages, without requiring inter-stage reactant injections. Embodiments of the present invention also provide techniques for compensating for membrane performance degradation and other changes in system operating conditions that negatively affect synthesis gas production.

  16. Correction factor to determine total hydrogen+deuterium concentration obtained by inert gas fusion-thermal conductivity detection (IGF- TCD) technique

    International Nuclear Information System (INIS)

    Ramakumar, K.L.; Sesha Sayi, Y.; Shankaran, P.S.; Chhapru, G.C; Yadav, C.S.; Venugopal, V.

    2004-01-01

    The limitation of commercially available dedicated equipment based on Inert Gas Fusion- Thermal Conductivity Detection (IGF - TCD) for the determination of hydrogen+deuterium is described. For a given molar concentration, deuterium is underestimated vis a vis hydrogen because of lower thermal conductivity and not considering its molecular weight in calculations. An empirical correction factor based on the differences between the thermal conductivities of hydrogen, deuterium and the carrier gas argon, and the mole fraction of deuterium in the sample has been derived to correct the observed hydrogen+deuterium concentration. The corrected results obtained by IGF - TCD technique have been validated by determining hydrogen and deuterium contents in a few samples using an independent method based on hot vacuum extraction-quadrupole mass spectrometry (HVE-QMS). Knowledge of mole fraction of deuterium (XD) is necessary to effect the correction. The correction becomes insignificant at low X D values (XD < 0.2) as the precision in the IGF measurements is comparable with the extent of correction. (author)

  17. Seismic fracture detection of shale gas reservoir in Longmaxi formation, Sichuan Basin, China

    Science.gov (United States)

    Lu, Yujia; Cao, Junxing; Jiang, Xudong

    2017-11-01

    In the shale reservoirs, fractures play an important role, which not only provide space for the oil and gas, but also offer favorable petroleum migration channel. Therefore, it is of great significance to study the fractures characteristics in shale reservoirs for the exploration and development of shale gas. In this paper, four analysis technologies involving coherence, curvature attribute, structural stress field simulation and pre-stack P-wave azimuthal anisotropy have been applied to predict the fractures distribution in the Longmaxi formation, Silurian, southeast of Sichuan Basin, China. By using the coherence and curvature attribute, we got the spatial distribution characteristics of fractures in the study area. Structural stress field simulation can help us obtain distribution characteristics of structural fractures. And using the azimuth P-wave fracture detection technology, we got the characteristics about the fracture orientation and density of this region. Application results show that there are NW and NE fractures in the study block, which is basically consistent with the result of log interpretation. The results also provide reliable geological basis for shale gas sweet spots prediction.

  18. Quality-of-service sensitivity to bio-inspired/evolutionary computational methods for intrusion detection in wireless ad hoc multimedia sensor networks

    Science.gov (United States)

    Hortos, William S.

    2012-06-01

    In the author's previous work, a cross-layer protocol approach to wireless sensor network (WSN) intrusion detection an identification is created with multiple bio-inspired/evolutionary computational methods applied to the functions of the protocol layers, a single method to each layer, to improve the intrusion-detection performance of the protocol over that of one method applied to only a single layer's functions. The WSN cross-layer protocol design embeds GAs, anti-phase synchronization, ACO, and a trust model based on quantized data reputation at the physical, MAC, network, and application layer, respectively. The construct neglects to assess the net effect of the combined bioinspired methods on the quality-of-service (QoS) performance for "normal" data streams, that is, streams without intrusions. Analytic expressions of throughput, delay, and jitter, coupled with simulation results for WSNs free of intrusion attacks, are the basis for sensitivity analyses of QoS metrics for normal traffic to the bio-inspired methods.

  19. Method for predicting peptide detection in mass spectrometry

    Science.gov (United States)

    Kangas, Lars [West Richland, WA; Smith, Richard D [Richland, WA; Petritis, Konstantinos [Richland, WA

    2010-07-13

    A method of predicting whether a peptide present in a biological sample will be detected by analysis with a mass spectrometer. The method uses at least one mass spectrometer to perform repeated analysis of a sample containing peptides from proteins with known amino acids. The method then generates a data set of peptides identified as contained within the sample by the repeated analysis. The method then calculates the probability that a specific peptide in the data set was detected in the repeated analysis. The method then creates a plurality of vectors, where each vector has a plurality of dimensions, and each dimension represents a property of one or more of the amino acids present in each peptide and adjacent peptides in the data set. Using these vectors, the method then generates an algorithm from the plurality of vectors and the calculated probabilities that specific peptides in the data set were detected in the repeated analysis. The algorithm is thus capable of calculating the probability that a hypothetical peptide represented as a vector will be detected by a mass spectrometry based proteomic platform, given that the peptide is present in a sample introduced into a mass spectrometer.

  20. High-pressure 3He-Xe gas scintillators for simultaneous detection of neutrons and gamma rays over a large energy range

    International Nuclear Information System (INIS)

    Tornow, W.; Esterline, J.H.; Leckey, C.A.; Weisel, G.J.

    2011-01-01

    We report on features of high-pressure 3 He-Xe gas scintillators which have not been sufficiently addressed in the past. Such gas scintillators can be used not only for the efficient detection of low-energy neutrons but at the same time for the detection and identification of γ-rays as well. Furthermore, 3 He-Xe gas scintillators are also very convenient detectors for fast neutrons in the 1-10 MeV energy range and for high-energy γ-rays in the 7-15 MeV energy range. Due to their linear pulse-height response and self calibration via the 3 He(n,p) 3 H reaction, neutron and γ-ray energies can easily be determined in this high-energy regime.