  1. Comments on a Method to Measure Sucralose Using UV Photodegradation Followed by UV Spectrophotometry.

    Science.gov (United States)

    Fang, Te; Andrews, Susan A; Hofmann, Ron

    2017-05-01

    A simple and quick method to measure sucralose in aqueous solution at concentrations in the order of 0.1-1.2 g·L-1 proposed by Idris et al. uses UV irradiation prior to UV spectrophotometry. The photolysis of sucralose forms a photoactive compound characterized by maximum absorbance at approximately 270 nm. The conditions required for sucralose photolysis, however, had not been completely reported. In this work, the procedure described by Idris et al. was replicated using a low-pressure UV lamp to irradiate sucralose samples with a wider range of initial concentrations (0.04-10 g·L-1) with known fluences. It was determined that care must be taken to ensure that the same fluence is applied for both calibration and measurement steps because the absorbance of the sucralose photolysis product is a function of the applied fluence. The way the samples are irradiated also has an impact on the results in that the method exhibits a greater linear range if an apparatus is used that maximizes the fluence rate (e.g., by placing samples closer to the UV source or using a higher-intensity lamp).

  2. A new method for rapid determination of carbohydrate and total carbon concentrations using UV spectrophotometry.

    Science.gov (United States)

    Albalasmeh, Ammar A; Berhe, Asmeret Asefaw; Ghezzehei, Teamrat A

    2013-09-12

    A new UV spectrophotometry based method for determining the concentration and carbon content of carbohydrate solution was developed. This method depends on the inherent UV absorption potential of hydrolysis byproducts of carbohydrates formed by reaction with concentrated sulfuric acid (furfural derivatives). The proposed method is a major improvement over the widely used Phenol-Sulfuric Acid method developed by DuBois, Gilles, Hamilton, Rebers, and Smith (1956). In the old method, furfural is allowed to develop color by reaction with phenol and its concentration is detected by visible light absorption. Here we present a method that eliminates the coloration step and avoids the health and environmental hazards associated with phenol use. In addition, avoidance of this step was shown to improve measurement accuracy while significantly reducing waiting time prior to light absorption reading. The carbohydrates for which concentrations and carbon content can be reliably estimated with this new rapid Sulfuric Acid-UV technique include: monosaccharides, disaccharides and polysaccharides with very high molecular weight. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. THE DETERMINATION OF BUPROPION HYDROCHLORIDE IN PHARMACEUTICAL DOSAGE FORMS BY ORIGINAL UV- AND SECOND DERIVATIVE UV SPECTROPHOTOMETRY, POTENTIOMETRIC AND CONDUCTOMETRIC METHODS

    Directory of Open Access Journals (Sweden)

    Duygu YENİCELİ

    2010-08-01

    Full Text Available Spectrophotometric, potentiometric and conductometric methods are developed for the determination of bupropion hydrochloride (BLIP in pharmaceutical tablets. For the first method, original UV-spectrophotometry, 252 nm was determined as the optimum wavelength and used for the determinations. For the other method, second derivative UV spectrophotometry, the absorbances were measured at 217.4 and 221.8 nm and the distance between these extremum values was determined according to peak to peak method. Two spectrophotometric methods were validated over the concentration range of 5.72 - 20.03 ug/mL. The limit of detection and limit of quantitation values of original UV-spectrophotometry were 0.75 ug/mL and 2.28 jug/mL. Also, these parameters were determined as 0.23 ug/mL and 0.68 ug/mL respectively, for the second derivative UV spectrophotometry. Developed methods were fully validated and the applicability of the methods for the determination of BUP in pharmaceuticals were demonstrated. Also, simple potentiometric and conductometric methods were developed and the applicability of these methods were demonstrated. The results of four analytical methods were compared with ANOVA test and no significant difference was found statistically. As a result, the developed methods could be proposed to the rutin content analysis to be simple, cheap, accurate, and precise

  4. Validation of quantitative analysis method for triamcinolone in ternary complexes by UV-Vis spectrophotometry

    Directory of Open Access Journals (Sweden)

    GEORGE DARLOS A. AQUINO

    2011-06-01

    Full Text Available Triamcinolone (TRI, a drug widely used in the treatment of ocular inflammatory diseases, is practically insoluble in water, which limits its use in eye drops. Cyclodextrins (CDs have been used to increase the solubility or dissolution rate of drugs. The purpose of the present study was to validate a UV-Vis spectrophotometric method for quantitative analysis of TRI in inclusion complexes with beta-cyclodextrin (B-CD associated with triethanolamine (TEA (ternary complex. The proposed analytical method was validated with respect to the parameters established by the Brazilian regulatory National Agency of Sanitary Monitoring (ANVISA. The analytical measurements of absorbance were made at 242nm, at room temperature, in a 1-cm path-length cuvette. The precision and accuracy studies were performed at five concentration levels (4, 8, 12, 18 and 20μg.mL-1. The B-CD associated with TEA did not provoke any alteration in the photochemical behavior of TRI. The results for the measured analytical parameters showed the success of the method. The standard curve was linear (r2 > 0.999 in the concentration range from 2 to 24 μg.mL-1. The method achieved good precision levels in the inter-day (relative standard deviation-RSD <3.4% and reproducibility (RSD <3.8% tests. The accuracy was about 80% and the pH changes introduced in the robustness study did not reveal any relevant interference at any of the studied concentrations. The experimental results demonstrate a simple, rapid and affordable UV-Vis spectrophotometric method that could be applied to the quantitation of TRI in this ternary complex. Keywords: Validation. Triamcinolone. Beta-cyclodextrin. UV- Vis spectrophotometry. Ternary complexes. RESUMO Validação de método de análise quantitativa para a triancinolona a partir de complexo ternário por espectrofotometria de UV-Vis A triancinolona (TRI é um fármaco amplamente utilizado no tratamento de doenças inflamatórias do globo ocular e

  5. Comparison of HPLC, UV spectrophotometry and potentiometric titration methods for the determination of lumefantrine in pharmaceutical products.

    Science.gov (United States)

    da Costa César, Isabela; Nogueira, Fernando Henrique Andrade; Pianetti, Gérson Antônio

    2008-09-10

    This paper describes the development and evaluation of a HPLC, UV spectrophotometry and potentiometric titration methods to quantify lumefantrine in raw materials and tablets. HPLC analyses were carried out using a Symmetry C(18) column and a mobile phase composed of methanol and 0.05% trifluoroacetic acid (80:20), with a flow rate of 1.0ml/min and UV detection at 335nm. For the spectrophotometric analyses, methanol was used as solvent and the wavelength of 335nm was selected for the detection. Non-aqueous titration of lumefantrine was carried out using perchloric acid as titrant and glacial acetic acid/acetic anhydride as solvent. The end point was potentiometrically determined. The three evaluated methods showed to be adequate to quantify lumefantrine in raw materials, while HPLC and UV methods presented the most reliable results for the analyses of tablets.

  6. UV spectrophotometry of the Metronidazole

    Directory of Open Access Journals (Sweden)

    O. I. Panasenko

    2013-10-01

    Full Text Available Objective. The purpose of this research was to study the UV spectrum of Metronidazole in different polarity solvents (water, 95 % ethanol, 0,1 M sodium hydroxide, 0,1 M hydrochloric acid and 5 M sulfuric acid solution, to establish the relationship between chemical structure of the analyzed compounds and the nature of their electronic spectrum. In addition, a detailed study of the ultraviolet spectra of Metronidazole in different solutions enables to select the optimal wavelength and a thinner design for Metronidazole in substance and dosage forms. Materials and methods. Spectrophotometer SPECORD 200-222U214 has been used for study of the UV spectra of Metronidazole, the quantitative methods were used. Measuring of the absorption of Metronidazole solutions has been carried out in quartz cuvettes with a layer thickness of 10 mm. Due to the fact that the test material shows selective absorption in the ultraviolet spectra, model compounds were studied at a concentration of 1 mg%. Study of electronic spectra was performed in the range of 200 to 400 nm, and the curve has been constructed in coordinates A = f (λ. It has been used water, 95% ethanol, 0,1 M NaOH, 0,1 M HCl and 5 M H2SO4 as solvents. The content of Metronidazole in substance and dosage forms calculated with the equations according to SPU. The results. Study of the UV spectra of Metronidazole and its model compounds showed that in short-wave part of spectrum due to absorption and excitation electrons of imidazole ring were transferred, and in long-wave – conjugation chromophore imidazole cycle and nitro group as electron acceptor occurred. Analysis of the UV spectra of Metronidazole enables to determine a maximum of the analytical quantification of the medicine. Conclusions. Metronidazole UV spectra in water, 95% ethanol, 0,1 M solution of NaOH, 0,1 M solution of HCl and 5 M solution of H2SO4 have been studied. Metronidazole UV spectra are characterized by two absorption bands in the

  7. Simultaneous quantitative determination of paracetamol and tramadol in tablet formulation using UV spectrophotometry and chemometric methods

    Science.gov (United States)

    Glavanović, Siniša; Glavanović, Marija; Tomišić, Vladislav

    2016-03-01

    The UV spectrophotometric methods for simultaneous quantitative determination of paracetamol and tramadol in paracetamol-tramadol tablets were developed. The spectrophotometric data obtained were processed by means of partial least squares (PLS) and genetic algorithm coupled with PLS (GA-PLS) methods in order to determine the content of active substances in the tablets. The results gained by chemometric processing of the spectroscopic data were statistically compared with those obtained by means of validated ultra-high performance liquid chromatographic (UHPLC) method. The accuracy and precision of data obtained by the developed chemometric models were verified by analysing the synthetic mixture of drugs, and by calculating recovery as well as relative standard error (RSE). A statistically good agreement was found between the amounts of paracetamol determined using PLS and GA-PLS algorithms, and that obtained by UHPLC analysis, whereas for tramadol GA-PLS results were proven to be more reliable compared to those of PLS. The simplest and the most accurate and precise models were constructed by using the PLS method for paracetamol (mean recovery 99.5%, RSE 0.89%) and the GA-PLS method for tramadol (mean recovery 99.4%, RSE 1.69%).

  8. Uranium determination by UV-Vis spectrophotometry in organic matrix

    International Nuclear Information System (INIS)

    Iwaki, Leonardo E.O.; Silva, Ieda S.; Oliveira, Luis C.

    2013-01-01

    Concentrations of uranium in the process samples provide essential information required for nuclear process monitoring. A large number of techniques have been developed to allow uranium determination, but each technique possesses some advantages and disadvantages and cannot be applied without difficulty to all samples. The ultraviolet visible spectrophotometry (UV-Vis) is widely method used in analytical industrial processes due to its simplicity, rapidity, low costs, low generation of analytical waste, easy calibration and operation. In this study, we describe a simple and fast quantification method to determination of a high amount of uranium in organic phase (TBP/kerosene) using UV-Vis spectrophotometry. The process sample was analyzed in UV-Vis and compared with inductively coupled plasma optical emission spectrometry (ICP OES) showing similar results in both methods. The statistical tests (Student-t and Fischer) showed that the both techniques they are equivalent. (author)

  9. Comparative study of analytical methods by direct and first-derivative UV spectrophotometry for evaluation of losartan potassium in capsules

    Directory of Open Access Journals (Sweden)

    Rudy Bonfilio

    2010-03-01

    Full Text Available Losartan potassium is an antihypertensive non-peptide agent, which exerts its action by specific blockade of angiotensin II receptors. The aim of the present study was the validation and application of analytical methods for the quality control of losartan potassium 50 mg in pharmaceutical capsules, using direct and first-derivative UV spectrophotometry. Based on losartan potassium spectrophotometric characteristics, a signal at 205 nm of the zero-order spectrum and a signal at 234 nm of the first-derivative spectrum, were found adequate for quantification. The results were used to compare these instrumental techniques. The linearity between the signals and concentrations of losartan potassium in the ranges of 3.0-7.0 mg L-1 and 6.0-14.0 mg L-1 for direct and first-derivative spectrophotometry in aqueous solutions, respectively, presented a correlation coefficient (r of 0.9999 in both cases. The methods were applied for losartan potassium in capsule dosage obtained from local pharmacies, and were shown to be efficient, easy to apply and low cost. These methods do not use polluting reagents and require relatively inexpensive equipment.O losartano potássico é um agente anti-hipertensivo não peptídico, que exerce sua ação por bloqueio específico dos receptores da angiotensina II. Este trabalho propôs a validação e aplicação de métodos analíticos orientados ao controle de qualidade de losartano potássico 50 mg na forma farmacêutica cápsula, utilizando a espectrofotometria direta e derivada de primeira ordem na região do UV. Baseado nas características espectrofotométricas de losartano potássico, um sinal a 205 nm do espectro de ordem zero e um sinal a 234 nm do espectro de primeira derivada foram adequados para a quantificação. Os resultados foram usados para comparar essas duas técnicas instrumentais. O coeficiente de correlação entre as respostas e as concentrações de losartano potássico na faixa de 3,0-7,0 mg L-1 e 6

  10. UV-VIS spectrophotometry method for the determination of titanium and aluminum in zirconyl chloride

    International Nuclear Information System (INIS)

    Purwanto A; Farida Emawati

    2013-01-01

    Analysis of Ti and Al in zirconyl chloride (ZrOCI 2 .8 H 2 0) with a spectrophotometric method has been studied. Analysis of Ti based on the formation of a yellow complex from the reaction of Ti (IV) with H 2 O 2 in sulfuric acid solution. Studied the influence of zirconium, the determination of detection limits, precision and accuracy test. Spectrophotometric analysis of Ti obtained optimum conditions: wavelength (A) 400 nm, while the stability of complexes is 5-15 minutes, the concentration of complexing H 2 O 2 is 0.3%, sulfuric acid concentrations is 1.0 M, the detection limit is 0.103 µg/mL. Standard curve was linear in the range of concentrations from 1.0 to 30.0 µ/mL with r = 0.999. Zirconium with 20 times concentration of Ti is interference. Content of Ti in ZrOCl 2 . 8 H 2 O obtained average 0.0048 ± 0.0002%. Testing precision of Ti with coefficient variation is 4.8% and accuracy is 91.4%. Analysis of AI obtained optimum conditions are : λ 536 nm, stable complexes is 7-10 minutes, the concentration of eriokrom cyanine is 3,73.10-5 M, ascorbic acid 0.02%. Standard curve AI with the range concentrations of 10-50 ng/mL is linear with r = 0.999. Zirconium with a concentration of 10 time is not interference. Samples solution in 0.5 M H 2 SO 4 , extracted with 30% trioctylamine-kerosene, water phase was analyzed. Contents of AI in ZrOCI 2 . 8 H 2 0 local products obtained average 0.0030 ± 0.0001%. The precision is 2.48% and accuracy is 89.3%. (author)

  11. High-throughput screening assay used in pharmacognosy: Selection, optimization and validation of methods of enzymatic inhibition by UV-visible spectrophotometry

    Directory of Open Access Journals (Sweden)

    Graciela Granados-Guzmán

    2014-02-01

    Full Text Available In research laboratories of both organic synthesis and extraction of natural products, every day a lot of products that can potentially introduce some biological activity are obtained. Therefore it is necessary to have in vitro assays, which provide reliable information for further evaluation in in vivo systems. From this point of view, in recent years has intensified the use of high-throughput screening assays. Such trials should be optimized and validated for accurate and precise results, i.e. reliable. The present review addresses the steps needed to develop and validate bioanalytical methods, emphasizing UV-Visible spectrophotometry as detection system. Particularly focuses on the selection of the method, the optimization to determine the best experimental conditions, validation, implementation of optimized and validated method to real samples, and finally maintenance and possible transfer it to a new laboratory.

  12. Estimation of nitrate and nitrogen forms of vegetables by UV-spectrophotometry after photo-oxydation.

    Science.gov (United States)

    Ribeiro, T; Depres, S; Couteau, G; Pauss, A

    2003-01-01

    An alternative method for the estimation of nitrate and nitrogen forms in vegetables is proposed. Nitrate can be directly estimated by UV-spectrophotometry after an extraction step with water. The other nitrogen compounds are photo-oxidized into nitrate, and then estimated by UV-spectrophotometry. An oxidative solution of sodium persulfate and a Hg-UV lamp is used. Preliminary assays were realized with vegetables like salade, spinachs, artichokes, small peas, broccolis, carrots, watercress; acceptable correlations between expected and experimental values of nitrate amounts were obtained, while the detection limit needs to be lowered. The optimization of the method is underway.

  13. Contribution to Casein Determination by UV Spectrophotometry

    Directory of Open Access Journals (Sweden)

    Stefanescu Raluca

    2017-12-01

    Full Text Available In the present paper, the interaction between copper ions and proteins is presented, in order to elaborate a simple and rapid spectrophotometric assay of casein in milk. Under alkaline conditions, copper ions form the biuret complex with the proteins, which can be used in protein determination. Although very specific, the biuret method is less sensitive. Using insoluble copper phosphate, casein is able to extract copper ions, with which it forms the biuret complex, while either the complex or copper ions could be determined in the ultraviolet range. Indeed, an increased absorbance of biuret complex at 215 nm was found. Nevertheless, copper ions can be determined in UV as well, their concentration being proportional to that of casein. When used tetraglycine instead casein, mass spectrometric measurements at pH higher than 11 revealed the formation of complexes with many copper ions bound to each peptide bond-containing molecule. Nevertheless, on diluting the biuret solution the complex may dissociate leading to very complex UV spectra that should be further studied.

  14. Ionic Liquid Dispersive Liquid-Liquid Microextraction Method for the Determination of Irinotecan, an Anticancer Drug, in Water and Urine Samples Using UV-Vis Spectrophotometry.

    Science.gov (United States)

    Uysal, Deniz; Karadaş, Cennet; Kara, Derya

    2017-05-01

    A new, simple, efficient, and environmentally friendly ionic liquid dispersive liquid-liquid microextraction method was developed for the determination of irinotecan, an anticancer drug, in water and urine samples using UV-Vis spectrophotometry. The ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate was used as the extraction solvent, and ethanol was used as the disperser solvent. The main parameters affecting the extraction efficiency, including sample pH, volume of the ionic liquid, choice of the dispersive solvent and its volume, concentration of NaCl, and extraction and centrifugation times, were investigated and optimized. The effect of interfering species on the recovery of irinotecan was also examined. Under optimal conditions, the LOD (3σ) was 48.7 μg/L without any preconcentration. Because the urine sample was diluted 10-fold, the LOD for urine would be 487 μg/L. However, this could be improved 16-fold if preconcentration using a 40 mL aliquot of the sample is used. The proposed method was successfully applied to the determination of irinotecan in tap water, river water, and urine samples spiked with 10.20 mg/L for the water samples and 8.32 mg/L for the urine sample. The average recovery values of irinotecan determined were 99.1% for tap water, 109.4% for river water, and 96.1% for urine.

  15. Development of the H-point standard additions method for coupled liquid-chromatography and UV-visible spectrophotometry

    Energy Technology Data Exchange (ETDEWEB)

    Campins-Falco, Pilar; Bosch-Reig, Francisco; Herraez-Hernandez, Rosa; Sevillano-Cabeza, Adela (Universidad de Valencia (Spain). Facultad de Quimica, Departamento de Quimica Analitica)

    1992-02-10

    This work establishes the fundamentals of the H-point standard additions method for liquid chromatography for the simultaneous analysis of binary mixtures with overlapped chromatographic peaks. The method was compared with the deconvolution method of peak suppression and the second derivative of elution profiles. Different mixtures of diuretics were satisfactorily resolved. (author). 21 refs.; 9 figs.; 2 tabs.

  16. Simultaneous Estimation of Ibuprofen and Phenylephrine Hydrochloride in Bulk and Combined Dosage Form by First Derivative UV Spectrophotometry Method

    Directory of Open Access Journals (Sweden)

    Mehul Patel

    2013-01-01

    Full Text Available A simple, precise, rapid, and economic method was developed for the simultaneous determination of Ibuprofen and Phenylephrine HCl in bulk and combined dosage form. This method involves first-order derivative spectroscopy using 248 nm and 237 nm as zero crossing points for Ibuprofen and Phenylephrine HCl, respectively. For spectrophotometric method 0.1 N NaOH was used as a solvent. The linearity was established over the concentration range of 12–72 μg/mL and 1.5–22 μg/mL for Ibuprofen and Phenylephrine HCl with correlation coefficient (r2 of 0.9972 and 0.9981, respectively. The mean % recoveries were found to be in the range of 98.88% and 98.54% for Ibuprofen and Phenylephrine HCl, respectively. Interday and intraday studies showed repeatability of the method. The method was found to be specific and robust. The method was successfully applied to pharmaceutical formulation, with no interference from excipients as indicated by the recovery study. Results of analysis were validated statistically and by recovery studies.

  17. Linearization of the Bradford protein assay to application in cow milk proteins quantification by UV-Vis spectrophotometry method.

    OpenAIRE

    SANTOS, A. S. de O. dos; COSTA, F. F.; ESTEVES, W. T.; BRITO, M. A. V. P. e; FURTADO, M. A. M.; MARTINS, M. F.

    2015-01-01

    Reliable methods for determination and quantification of total protein in food are essential information to ensure quality and safety of food trade. The objective of this study was to evaluate the linearity of calibration curves obtained from different proteins (blood serum albumin-BSA, α-LA, β-LG, αs, β and κ-CAS) with the reagent of Bradford. Comercial UHT skimmed bovine milk was analyzed for the determination of total protein using the Bradford method by reading at 595 nm. The determinatio...

  18. LINEARIZATION OF THE BRADFORD PROTEIN ASSAY TO APPLICATION IN COW MILK PROTEINS QUANTIFICATION BY UV-Vis SPECTROPHOTOMETRY METHOD

    Directory of Open Access Journals (Sweden)

    Alessa Siqueira de Oliveira dos Santos

    2015-01-01

    Full Text Available Reliable methods for determination and quantification of total protein in food are essential information to ensure quality and safety of food trade. The objective of this study was to evaluate the linearity of calibration curves obtained from different proteins (blood serum albumin-BSA, α-LA, β-LG, caseins (CN: αs, β and κ-CAS with the reagent of Bradford. Comercial UHT skimmed bovine milk was analyzed for the determination of total protein using the Bradford method by reading at 595 nm. The determination of the concentrations of total milk protein was achieved by linear regression. The Bradford method showed a high sensitivity for the determination of total proteins in bovine milk dilution 1:25 to values closer to those obtained by the Kjeldahl method. The results showed that the calibration curve of standard proteins β-CN and BSA obtained better linearity with less variation in the absorbance measurements for the determination of total protein of milk.

  19. Study of kinetics of the tetroxane thermolysis by UV spectrophotometry

    International Nuclear Information System (INIS)

    Jorge, N.L.; Leiva, L.C.; Castellanos, M.G.; Cafferata, L.F.R.; Gomez V, M.E.

    2002-01-01

    The 3,3,6,6-tetramethyl-1,2,4,5-tetroxane (ACDP) in methanol solution shows an absorbance peak at low wave length in UV spectrum and follows the Lambert Beer law until 10-2 M concentration at 209 nm. The ACDP thermal decomposition have been studied by the UV spectroscopy like an alternative method to find out the kinetic parameters from the thermolysis of these compounds. The rate constants at the temperatures and initial concentration ranges of 130-166 and 0,003-0,013 mol / L, respectively, and the activation parameters were similar to the corresponding values found by other methodology, verifying this analytic technique. Acetone produced during reaction no interference in ACDP quantification by UV analysis. (Author)

  20. Evolution of Instrumentation for UV-Visible Spectrophotometry. Part I.

    Science.gov (United States)

    Altemose, Ines R.

    1986-01-01

    Traces the development of instruments used in spectrophotometry. Discusses how spectrophotometric measurements are made. Describes the color comparator, the filter photometer, and the spectrophotometer. Outlines the evolution of optical systems, including light sources, the monochromator, the photodetector, double-beam optics, and split-beam…

  1. Direct DOC and nitrate determination in water using dual pathlength and second derivative UV spectrophotometry.

    Science.gov (United States)

    Causse, Jean; Thomas, Olivier; Jung, Aude-Valérie; Thomas, Marie-Florence

    2017-01-01

    UV spectrophotometry is largely used for water and wastewater quality monitoring. The measurement/estimation of specific and aggregate parameters such as nitrate and dissolved organic carbon (DOC) is possible with UV spectra exploitation, from 2 to multi wavelengths calibration. However, if nitrate determination from UV absorbance is known, major optical interferences linked to the presence of suspended solids, colloids or dissolved organic matter limit the relevance of UV measurement for DOC assessment. A new method based on UV spectrophotometric measurement of raw samples (without filtration) coupling a dual pathlength for spectra acquisition and the second derivative exploitation of the signal is proposed in this work. The determination of nitrate concentration is carried out from the second derivative of the absorbance at 226 nm corresponding at the inflexion point of nitrate signal decrease. A short optical pathlength can be used considering the strong absorption of nitrate ion around 210 nm. For DOC concentration determination the second derivative absorbance at 295 nm is proposed after nitrate correction. Organic matter absorbing slightly in the 270-330 nm window, a long optical pathlength must be selected in order to increase the sensitivity. The method was tested on several hundred of samples from small rivers of two agricultural watersheds located in Brittany, France, taken during dry and wet periods. The comparison between the proposed method and the standardised procedures for nitrate and DOC measurement gave a good adjustment for both parameters for ranges of 2-100 mg/L NO3 and 1-30 mg/L DOC. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. UV Spectrophotometry of the Galilean Satellites, Saturnian Satellites & Selected Asteroids

    Science.gov (United States)

    Nelson, Robert M.

    We propose a series of ultraviolet spectral observations of solid surfaces of selected solar system objects, specifically the Galilean satellites of Jupiter, several atmosphereless satellites of Saturn, and the asteroids, 5 Astraea, 18 Melpomene, 532 Herculina, 68 Leto, 31 Euphmsyne, 80 Sappho, 3 Juno, and 39 Laetitia. Historically such spectral observations have allowed for the Identification of spectrally active solid state materials on planetary surfaces. Furthermore, because the rotational properties are known for all the objects proposed for study, this technique will provide a longitude map of such materials on the objects' surfaces. The study of asteroid surface mineralogy is an important method of constraining solar system formation models. The asteroid spectra we have previously acquired with IUE have created unique subdivisions within the existent asteroid types. The new spectra will provide more sophisticated mineralogical characterizations of asteroid surface materials. Our other accomplishments with IUE include mapping of the distribution of condensed S02 on Io, identification of a longitudinal asymmetry on Europa associated with magnetospheric particle bombardment of the surface, and establishing the ultraviolet geometric albedo variation as a function of longitude for all the Galilean satellites. Because Io is the most volcanically active body In the solar system, and short tern variations in selected regions of the Jovian magnetosphere are known to occur, it is important to periodically check for temporal variations in the spectra of the Galilean satellites that may be due to variations n Io tectonic/volcanic activity, or magnetosphere changes. These proposed UV observations are critical to the design and operation of several instruments on Project Galileo, NASA's Jupiter Orbiter and Probe Mission. Spectra of Iapetus, Rhea and Dione have been acquired during the previous year; however, only at orbital locations near elongation. In addition, the dark

  3. Neutron dosimetry by UV and IR spectrophotometry of the newly developed dyed ECE tracks

    International Nuclear Information System (INIS)

    Sohrabi, M.; Sadeghi Bajd, S.

    1990-01-01

    New, large and high-contrasted dyed ECE recoil tracks have been successfully developed. The chief reason for this development has been the provision of large photon-absorbing sites on a non-absorbing unaffected polymer surface for UV and IR spectrophotometry. In this approach, ECE recoil tracks in polycarbonate were dyed using our optimised conditions; sensitisation in 20% by weight acrylic acid at 75 0 C for 3.5 h and dyeing in 3% by weight eosin at 95 0 C for 4 h. Spectrophotometry by UV and IR, track counting and optical densitometry were applied to the samples. These preliminary studies showed some promise for UV absorbance measurements for routine large-scale applications. the results of which are presented and discussed. (author)

  4. Using UV-VIS spectrophotometry for determining ecotoxicity of selected non-steroidal anti-inflammatory drugs

    Czech Academy of Sciences Publication Activity Database

    Čapka, Lukáš; Zlámalová Gargošová, H.; Vávrová, M.

    2015-01-01

    Roč. 24, 12C (2015), s. 4758-4762 ISSN 1018-4619 Institutional support: RVO:68081715 Keywords : ecotoxicity * NSAIDs * UV-VIS spectrophotometry Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 0.372, year: 2015

  5. UV SPECTROPHOTOMETRY APPLICATION FOR QUANTITATIVE DETERMINATION OF VINPOCETINE IN DRUG FORMULATIONS

    Directory of Open Access Journals (Sweden)

    J. V. Monaykina

    2014-12-01

    Full Text Available Introduction. In this paper simple, rapid and sensitive assay methods for quantitative determination of vinpocetine in two new drug formulations (suppositories and nasal cream are proposed. Analysis has been performed directly by using zero-order UV spectrophotometry. It is known from the special literature that the chromatographic techniques used for vinpocetine assay require expensive equipment and are rather time consuming. Therefore UV spectrophotometry is preferable due to its accuracy and simplicity. The object of this study was to develop new, simple, rapid, precise and accurate UV spectrophotometric procedure for the quantitative determination of vinpocetine in suppositories and nasal cream and evaluation of some validation characteristics of the methods. Materials and methods. The objects of the study were the new drug formulations of vinpocetine, namely 0,01 suppositories and 0,5% nasal cream developed by the scientists of The Chair of Technology of Drugs of Zaporizhzhia State Medical University. Distilled water and 0.05M HCl were used as the solvents, working standard sample of vinpocetine was used as a reference standard. Analytical equipment: spectrophotometer Specord 200, electronic balance ABT-120-5DM, measuring glassware of class A. Assay procedure: An accurately weighed sample of cream (1,200 – 2,000 g or one suppository was dissolved in 0.05M HCl and filtered into a 50,00 ml volumetric flask. Then the solution was brought to the mark with the same solvent and stirred. 3,00 ml or 4,00 ml of the resulting solutions (for suppositories or cream respectively were transferred into a 25,00 ml volumetric flask and brought to the mark with distilled water. Absorbance was measured at a wavelength of 272 nm on the blank of distilled water. The parallel measurement with 1,00 ml of 0,064% vinpocetine standard solution was carried out. The content of active substance was calculated according to standard formulas. Results. The suggested

  6. APPLICATION OF UV-SPECTROPHOTOMETRY FOR THE QUANTITATIVE DETERMINATION OF CAPTOPRIL IN DRUG

    Directory of Open Access Journals (Sweden)

    Yu. V. Monaykina

    2015-04-01

    Full Text Available Introduction. In this paper the simple, rapid and sensitive assay method for the quantitative determination of captopril in two new pharmaceutical formulations (suppositories and nasal gel is proposed. Analysis was performed directly by using zero-order UV spectrophotometry. It is known from the special literature that the chromatographic techniques used for captopril assay require the expensive equipment and are rather time consuming. Therefore UV spectrophotometry is preferable due to its accuracy, sensitivity and simplicity. The aim of this study was to develop and validate a new, simple, rapid, precise and accurate UV spectrophotometric method for the quantitative determination of captopril in suppositories and nasal gel. Materials and methods. The objects of the study were the new drug formulations of captopril, namely 0,05 suppositories and 2,5% nasal gel developed by the scientists of The Chair of Technology of Drugs ofZaporozhye State Medical University. Distilled water was used as the solvent, working standard sample of captopril was used as a reference standard. Analytical equipment: spectrophotometer Specord 200, electronic balance ABT-120-5DM, measuring glassware of class A. Assay procedure: An accurately weighed sample of gel (0,4000 –0,8000 g or one suppository was dissolved in distilled water and filtered into a volumetric flask (50,00 ml for gel and 250,0 ml for suppository . Then the solution was brought to the mark with the same solvent and stirred. 1,00 ml of the resulting solution was transferred into a 25,00 ml volumetric flask and brought to the mark with distilled water. Absorbance was measured at a wavelength of 203 nm on the blank of a solvent. The parallel measurement with 1,00 ml of 0,03% captopril standard solution was carried out. The content of active substance was calculated according to standard formulas. Results. The suggested procedure was successfully applied for the analysis of two new pharmaceutical

  7. Headspace single-drop microextraction coupled to microvolume UV-vis spectrophotometry for iodine determination

    International Nuclear Information System (INIS)

    Pena-Pereira, Francisco; Lavilla, Isela; Bendicho, Carlos

    2009-01-01

    Headspace single-drop microextraction has been combined with microvolume UV-vis spectrophotometry for iodine determination. Matrix separation and preconcentration of iodide following in situ volatile iodine generation and extraction into a microdrop of N,N'-dimethylformamide is performed. An exhaustive characterization of the microextraction system and the experimental variables affecting iodine generation from iodide was carried out. The procedure employed consisted of exposing 2.5 μL of N,N'-dimethylformamide to the headspace of a 10 mL acidic (H 2 SO 4 2 mol L -1 ) aqueous solution containing 1.7 mol L -1 Na 2 SO 4 for 7 min. Addition of 1 mL of H 2 O 2 1 mol L -1 for in situ iodine generation was performed. The limit of detection was determined as 0.69 μg L -1 . The repeatability, expressed as relative standard deviation, was 4.7% (n = 6). The calibration working range was from 5 to 200 μg L -1 (r 2 = 0.9991). The large preconcentration factor obtained, ca. 623 in only 7 min, compensate for the 10-fold loss in sensitivity caused by the decreased optical path, which results in improved detection limits as compared to spectrophotometric measurements carried out with conventional sample cells. The method was successfully applied to the determination of iodine in water, pharmaceutical and food samples

  8. HPLC determination of flavonoid glycosides in Mongolian Dianthus versicolor Fisch. (Caryophyllaceae) compared with quantification by UV spectrophotometry.

    Science.gov (United States)

    Obmann, Astrid; Purevsuren, Sodnomtseren; Zehl, Martin; Kletter, Christa; Reznicek, Gottfried; Narantuya, Samdan; Glasl, Sabine

    2012-01-01

    Dianthus versicolor is used in traditional Mongolian medicine against liver impairment. Fractions enriched in flavone-di- and triglycosides were shown to enhance bile secretion. Therefore, reliable and accurate analytical methods are needed for the determination of these flavonoids in the crude drug and extracts thereof. To provide a validated HPLC-DAD (diode array detector) method especially developed for the separation of polar flavonoids and to compare the data obtained with those evaluated by UV spectrophotometry. Separations were carried out on an Aquasil® C₁₈-column (4.6 mm × 250.0 mm, 5 µm) with a linear gradient of acetonitrile and water (adjusted to pH 2.8 with trifluoroacetic acid) as mobile phase. Rutoside was employed as internal standard with linear behavior in a concentration range of 0.007-3.5 mg/mL. Accuracy was determined by spiking the crude drug with saponarin resulting in recoveries between 92% and 102%. The method allows the quantification of highly polar flavonoid glycosides and the determination of their total content. For saponarin a linear response was evaluated within the range 0.007-3.5 mg/mL (R²  > 0.9999). It was proven that threefold sonication represents a time-saving, effective and cheap method for the extraction of the polar flavonoid glycosides. The contents determined by HPLC were shown to be in agreement with those obtained employing UV spectrophotometry. The study has indicated that the newly developed HPLC method represents a powerful technique for the quality control of D. versicolor. Ultraviolet spectrophotometry may be used alternatively provided that the less polar flavonoids are removed by purification. Copyright © 2011 John Wiley & Sons, Ltd.

  9. Relative bioavailability studies on a locally manufactured aspirin tablets using UV spectrophotometry and HPLC

    International Nuclear Information System (INIS)

    Kwadzo, Ameko David

    2005-11-01

    Modern trends in drug analysis require use of less time consuming, efficient, cost effective, fast, reproducible, simple and convenient methods. Two analytical methods were employed for the determination, the UV spectrophotometry and the HPLC. Aspirin, which is rapidly deacetylated to salicylic acid after absorption into the plasma, is excreted in the urine. In determining the salicylic acid concentration in the urine, the absorbance was quantitated by a spectrometer at a wavelength of 540nm. Aspirin formed an amber coloured complex with ferric ions (Trinder’s reagent). The complex, which formed instantaneously at room temperature, was stable. The solution of the complex obeyed Beer’s law at 540nm, the wavelength of maximum absorption of radiation (λmax). Phenol—induced absorbance is quenched by acidifying the reaction mixture with phosphoric acid. An HPLC analytical method was used in determining the free salicylate excreted in the urine. The mobile phase employed is a validated method from the USP- XXII (1990) which consists of water, methanol and glacial acetic acid in the ratio 69: 28: 3 respectively. The chromatographic conditions involved a flow rate of 1.0ml/rnin, wavelength of maximum absorption of 236nrn, stationary phase Spherisorb S5 ODS 1 phase sep column with standard dimensions of 25.0 cm length and 4.6cm diameter and chart recorder speed of 5mm/min. The quality of the reference and the test tablets were assessed by a number of standard tests, which include uniformity of weight, friability, hardness and dissolution that fall within the BP 2000 specification. The observation from the study reveals that the relative bioavailability of aspirin (w.r.t. salicylic acid) were 103.39% and 94.93% for HPLC and UV respectively. The mean cumulative percentage of the drug excreted in both cases were ii .05% and 10.69% for test and reference respectively for HPLC and 76.45% and 80.53% for test and reference respectively for UV analysis. The cumulative amount

  10. UV spectrophotometry for monitoring the performance of a yeast-based deoxygenation process to treat ships' ballast water.

    Science.gov (United States)

    Veilleux, Éloïse; de Lafontaine, Yves; Thomas, Olivier

    2016-04-01

    This study assessed the usefulness of UV spectrophotometry for the monitoring of a yeast-based deoxygenation process proposed for ships' ballast water treatment to prevent the transfer of aquatic invasive species. Ten-day laboratory experiments using three treatment concentrations and different water types were conducted and resulted in complete oxygen depletion of treated waters. The treatment performance and quality of treated waters were determined by measuring the UV-visible absorbance spectra of water samples taken over time. Samples were also used for laboratory analysis of water quality properties. The UV absorbance spectra values were strongly correlated (r = 0.96) to yeast cell density in treated waters. The second-order derivative (D (2)) of the spectra varied greatly over time, and the spectrum profiles could be divided into two groups corresponding to the oxygenated and anoxic phases of the treatment. The D (2) value at 215 nm was strongly correlated (r = 0.94) to ammonia levels, which increased over time. The D (2) value at 225 nm was strongly correlated (r > 0.97) to DO concentration. Our results showed that UV spectrophotometry may provide a rapid assessment of the behavior and performance of the yeast bioreactor over time by quantifying (1) the density of yeast cells, (2) the time at which anoxic conditions were reached, and (3) a water quality index of the treated water related to the production of ammonia. We conclude that the rapidity of the technique confers a solid advantage over standard methods used for water quality analysis in laboratory and would permit the direct monitoring of the treatment performance on-board ships.

  11. Determination of rare earth element content in yttrium aluminium garnet crystals by absorption spectrophotometry method

    International Nuclear Information System (INIS)

    Mejl'man, M.L.; Kolomijtsev, A.I.; Baskakova, Z.M.; Bagdasarov, Kh.S.; Kevorkov, A.M.

    1985-01-01

    Possibility of determination of relative and absolute contents of impurity trivalent REE ions in yttrium aluminium garnet of (YAG) monocrystals has been studied by the absorption spectrophotometry method. Absorption spectra in UV and visible regions YAG monocrystals doped by REE are studied. For each admixture the characteristic lines or absorption bands not overlapping with lines of other admixtures are defined and investigated. The extinction coefficients of characteristic lines are determined which allow one to measure absolute REE admixture concentrations in garnet crystals. A conclusion is drawn that the absorption spectrophotometry method permits to measure REE admixture content in YAG monocrystals within the concentration range of approximately 1x10sup(-3)-5 mas. % with an accuracy not less than 20% (with sample thickness of approximately 1 cm)

  12. Estimation of nitrite in source-separated nitrified urine with UV spectrophotometry.

    Science.gov (United States)

    Mašić, Alma; Santos, Ana T L; Etter, Bastian; Udert, Kai M; Villez, Kris

    2015-11-15

    Monitoring of nitrite is essential for an immediate response and prevention of irreversible failure of decentralized biological urine nitrification reactors. Although a few sensors are available for nitrite measurement, none of them are suitable for applications in which both nitrite and nitrate are present in very high concentrations. Such is the case in collected source-separated urine, stabilized by nitrification for long-term storage. Ultraviolet (UV) spectrophotometry in combination with chemometrics is a promising option for monitoring of nitrite. In this study, an immersible in situ UV sensor is investigated for the first time so to establish a relationship between UV absorbance spectra and nitrite concentrations in nitrified urine. The study focuses on the effects of suspended particles and saturation on the absorbance spectra and the chemometric model performance. Detailed analysis indicates that suspended particles in nitrified urine have a negligible effect on nitrite estimation, concluding that sample filtration is not necessary as pretreatment. In contrast, saturation due to very high concentrations affects the model performance severely, suggesting dilution as an essential sample preparation step. However, this can also be mitigated by simple removal of the saturated, lower end of the UV absorbance spectra, and extraction of information from the secondary, weaker nitrite absorbance peak. This approach allows for estimation of nitrite with a simple chemometric model and without sample dilution. These results are promising for a practical application of the UV sensor as an in situ nitrite measurement in a urine nitrification reactor given the exceptional quality of the nitrite estimates in comparison to previous studies. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Determination of gadolinium by the method of derivative spectrophotometry

    International Nuclear Information System (INIS)

    Aleksandrova, N.N.; Mishchenko, V.T.; Poluehktov, N.S.; Mukomel', V.L.

    1988-01-01

    Technique for gadolinium determination at the presence of interfering rare earth elements, which is based on the derivative spectrophotometry method, is suggested. The technique is of increased selectivity and allows to determine gadolinium in the mixtures with elements, which presence in solution makes impossible to determine gadolinium directly. At binary mixtures analysis Sr relative standard deviation does not exceed 0.03, while at the analysis of more complex mixtures Sr increases up to 0.06

  14. Determination of Uranium In UO2 And U3O8 Powder Using UV-VIS Spectrophotometry

    International Nuclear Information System (INIS)

    Natalia Adventini; Diah Dwiana Lestiani; Muhayatun; Endah Damastuti

    2009-01-01

    Lab. TAR PTNBR BATAN - Bandung has been accredited by National Accreditation Committee on May 2 nd , 2006 as a test laboratory with number LP-311-ID, has to maintain its laboratory performance by participating in a proficiency test. In this activity, the determination of uranium in 2 samples of UO 2 with A1 and A2 codes and other 2 samples of U 3 O 8 with B1 and B2 codes using UV-Vis spectrophotometry was carried out. Colouring method was used by reacting thiocyanate ion with the uranyl ion in acidic solution to develop a stable yellow colour of uranyl thiocyanate complex solution and measured at wavelength of 380 nm. The result gave that concentration of uranium in A1, A2, B1 and B2 samples were 77.95; 75.29; 64.58 and 63.69% respectively. The Z-score value for A samples was - 1.99, meanwhile for B samples the Z score value of between laboratory was −1.29 with intra laboratory was -1,09. It meant that Z-score values for both samples were in good category. From this result, it showed that UV-Vis spectrophotometry is one of the several methods that can be used to determine uranium in UO 2 and U 3 O 8 powder. The Lab. TAR’s proficiency test for determination of uranium in UO 2 and U 3 O 8 gave a good result and it was hoped to support BATAN's program in the nuclear fuel field. (author)

  15. The UV-VIS spectrophotometry applied to color and stability study in colored mortars

    Directory of Open Access Journals (Sweden)

    Alejandre, F. J.

    1999-06-01

    Full Text Available In the field of methodologies for color studying, a research of it has been done on colored mortars by applying uv-vis spectrophotometry, instrumental technique which can be used for solid materials works, and previously applied to building materials study. Results obtained show that the mentioned technique permits to evaluate quantitatively and qualitatively colors in an easy and objective way, besides nowadays advantages of the instrumental analysis: digital color register, computerized data processing, and precision and exactness increment in chromatic comparisons.

    Dentro de las metodologías existentes para el estudio del color, se ha realizado una investigación del mismo en morteros coloreados por medio de la espectrofotometría UV-VIS, técnica instrumental que es adaptable al trabajo con materiales sólidos, y que ha sido aplicada anteriormente en el estudio de diversos materiales de construcción. Los resultados obtenidos muestran cómo la citada técnica permite además de evaluar cualitativamente y cuantitativamente los colores de forma sencilla y objetiva, el disponer de las ventajas que conlleva actualmente el análisis instrumental: registro digital del color, tratamiento informatizado de datos y aumento de precisión y exactitud en las comparaciones cromáticas.

  16. Method for rapidly determining a pulp kappa number using spectrophotometry

    Science.gov (United States)

    Chai, Xin-Sheng; Zhu, Jun Yong

    2002-01-01

    A system and method for rapidly determining the pulp kappa number through direct measurement of the potassium permanganate concentration in a pulp-permanganate solution using spectrophotometry. Specifically, the present invention uses strong acidification to carry out the pulp-permanganate oxidation reaction in the pulp-permanganate solution to prevent the precipitation of manganese dioxide (MnO.sub.2). Consequently, spectral interference from the precipitated MnO.sub.2 is eliminated and the oxidation reaction becomes dominant. The spectral intensity of the oxidation reaction is then analyzed to determine the pulp kappa number.

  17. A fast determination of nitrate in rain and surface waters by means of UV spectrophotometry

    International Nuclear Information System (INIS)

    Slanina, J.; Lingerak, W.A.; Bergman, L.

    1976-01-01

    Organic substances are the main interference in the direct U.V. spectrophotometric determination of nitrate at 210 nm. An active carbon filter (Filopur) is therefore proposed which adsorbs all organic interferences. With this filter the U.V. spectrophotometric method gives the same results as the Na-salicylate method. The reproducibility is generally better than 5%. One determination takes 50 s. (orig.) [de

  18. Quality control of test iodine in urine by spectrophotometry UV-Vis

    Science.gov (United States)

    Huda, Thorikul; Nafisah, Durotun; Kumorowulan, Suryati; Lestari, Sri

    2017-12-01

    A quality control of iodine test in with UV-Vis spectrophotometry has been done. The purpose of this research is to find out whether the test results of samples conducted by Clinical Office of Research and Development Of GAKI (BP2GAKI) laboratory are still controlled, feasible and reliable, and still consistent over time, as indicated by the control chart. Quality control parameters are linearity, precision, accuracy, limit of detection, and limit of quantification. Based on the quality control that has been done, obtained linearity (r)= -0.9974, the detection limit and the limit of quantitation are respectively 2.26 µg/L and 7.54 µg/L, while the accuracy is calculated by %recovery and precision with value % RSD are 97.4161% and 1.7136% respectively. The quality control of iodine test in urine using the control chart shows excellent or stable results for 30 days and no variation of the results is very different for each day.

  19. Detection of silver nanoparticles in seawater at ppb levels using UV-visible spectrophotometry with long path cells.

    Science.gov (United States)

    Lodeiro, Pablo; Achterberg, Eric P; El-Shahawi, Mohammad S

    2017-03-01

    Silver nanoparticles (AgNPs) are emerging contaminants that are difficult to detect in natural waters. UV-visible spectrophotometry is a simple technique that allows detection of AgNPs through analysis of their characteristic surface plasmon resonance band. The detection limit for nanoparticles using up to 10cm path length cuvettes with UV-visible spectrophotometry is in the 0.1-10ppm range. This detection limit is insufficiently low to observe AgNPs in natural environments. Here we show how the use of capillary cells with an optical path length up to 200cm, forms an excellent technique for rapid detection and quantification of non-aggregated AgNPs at ppb concentrations in complex natural matrices such as seawater. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Diagnosis of soils polluted by aromatic hydrocarbons; Diagnostic de sols pollues par des hydrocarbures aromatiques polycycliques (HAP) a l'aide de la spectrophotometrie UV

    Energy Technology Data Exchange (ETDEWEB)

    Crone, M

    2000-01-28

    Polycyclic aromatic hydrocarbons (PAHs) were produced by many pyrolytic or combustion processes. They were found in soils, often in high concentrations. Remediation of industrial sites contaminated by PAHs requires an initial diagnosis of the pollution. In this perspective, an analytical procedure based on UV spectrophotometry was developed and validated with about 80 soil samples. Different exploitation methods of the samples UV spectra enable to develop simple and rapid characterisation tools. A PAH UV index is proposed for the estimation of global PAH concentration. A more accurate exploitation of the spectra gives an indication on the presence or the absence of some individual PAH like benzo[a]pyrene. A maturity index based on a two wavelength approach constitutes an indicator of the potential evolution of soil contamination in natural conditions. Laboratory methodology was adapted to field analyses and a test kit was designed for this purpose. The test duration is 20 minutes. (author)

  1. Diagnosis of soils polluted by aromatic hydrocarbons; Diagnostic de sols pollues par des hydrocarbures aromatiques polycycliques (HAP) a l'aide de la spectrophotometrie UV

    Energy Technology Data Exchange (ETDEWEB)

    Crone, M.

    2000-01-28

    Polycyclic aromatic hydrocarbons (PAHs) were produced by many pyrolytic or combustion processes. They were found in soils, often in high concentrations. Remediation of industrial sites contaminated by PAHs requires an initial diagnosis of the pollution. In this perspective, an analytical procedure based on UV spectrophotometry was developed and validated with about 80 soil samples. Different exploitation methods of the samples UV spectra enable to develop simple and rapid characterisation tools. A PAH UV index is proposed for the estimation of global PAH concentration. A more accurate exploitation of the spectra gives an indication on the presence or the absence of some individual PAH like benzo[a]pyrene. A maturity index based on a two wavelength approach constitutes an indicator of the potential evolution of soil contamination in natural conditions. Laboratory methodology was adapted to field analyses and a test kit was designed for this purpose. The test duration is 20 minutes. (author)

  2. Chemometrics-assisted spectrophotometry method for the determination of chemical oxygen demand in pulping effluent.

    Science.gov (United States)

    Chen, Honglei; Chen, Yuancai; Zhan, Huaiyu; Fu, Shiyu

    2011-04-01

    A new method has been developed for the determination of chemical oxygen demand (COD) in pulping effluent using chemometrics-assisted spectrophotometry. Two calibration models were established by inducing UV-visible spectroscopy (model 1) and derivative spectroscopy (model 2), combined with the chemometrics software Smica-P. Correlation coefficients of the two models are 0.9954 (model 1) and 0.9963 (model 2) when COD of samples is in the range of 0 to 405 mg/L. Sensitivities of the two models are 0.0061 (model 1) and 0.0056 (model 2) and method detection limits are 2.02-2.45 mg/L (model 1) and 2.13-2.51 mg/L (model 2). Validation experiment showed that the average standard deviation of model 2 was 1.11 and that of model 1 was 1.54. Similarly, average relative error of model 2 (4.25%) was lower than model 1 (5.00%), which indicated that the predictability of model 2 was better than that of model 1. Chemometrics-assisted spectrophotometry method did not need chemical reagents and digestion which were required in the conventional methods, and the testing time of the new method was significantly shorter than the conventional ones. The proposed method can be used to measure COD in pulping effluent as an environmentally friendly approach with satisfactory results.

  3. A novel UV-photolysis approach with acetone and isopropyl alcohol for the rapid determination of fluoride in organofluorine-containing drugs by spectrophotometry.

    Science.gov (United States)

    Mullapudi, Venkata Balarama Krishna; Dheram, Karunasagar

    2018-01-01

    A UV photolysis decomposition (UVPD) method for the determination of fluoride in fluorine containing pharmaceuticals by spectrophotometry is reported. It is based on the use of high intensity UV-irradiation in the presence of a digesting solution comprising a mixture of acetone and isopropanol. For the optimization of the UVPD procedure, three bulk drugs (levofloxacin, nebivolol and efavirenz) were chosen as representatives of three diverse compounds containing a single fluorine atom, two fluorine atoms, and trifluoromethyl groups respectively. Operational conditions of the UVPD method, such as concentration and volume of reagents (acetone and isopropyl alcohol), and UV irradiation time (1-6 minutes) were optimized. The efficiency of digestion was evaluated by the determination of fluoride in sample digests. Using the developed method, it was possible for complete conversion of the organofluoride to free fluoride ion for its subsequent determination by spectrophotometry based on bleaching of Zr-xylenol orange-color complex. Quantitative recovery (>98%) of the fluorine in the drug samples could be achieved using a mixture of 2% acetone + 2% isopropyl alcohol + 0.003% Na 2 CO 3 in just 5 minutes of UV irradiation, which can be considered an important aspect considering the difficulties involved in the cleavage of the CF bond. Accuracy was evaluated by comparison of results obtained by the UVPD method with the values estimated using formula weight of the compound and no statistical difference was observed between the results. Therefore, the proposed method is suitable for application in routine analysis of fluoride in organofluorine-containing drugs. Copyright © 2016. Published by Elsevier B.V.

  4. Lead Quantification in Urine Samples of Athletes by Coupling DLLME with UV-Vis Spectrophotometry.

    Science.gov (United States)

    Faraji, Hakim; Helalizadeh, Masoumeh

    2017-04-01

    Urine lead level is one of the most employed measures of lead exposure and risk. The urine samples used in this study were obtained from ten healthy male cyclists. Dispersive liquid-liquid microextraction combined with ultraviolet and visible spectrophotometry was utilized for preconcentration, extraction, and determination of lead in urine samples. Optimization of the independent variables was carried out based on chemometric methods in three steps. According to the screening and optimization study, 133 μL of CCl 4 (extracting solvent), 1.34 mL ethanol (dispersing solvent), pH 2.0, 0.00 % of salt, and 0.1 % O,O-diethyl dithiophosphoric (chelating agent) were used as the optimum independent variables for microextraction and determination of lead. Under the optimized conditions, R 2 was 0.9991, and linearity range was 0.01-100 μg L -1 . Precision was evaluated in terms of repeatability and intermediate precision, with relative standard deviations being <9.1 and <15.3 %, respectively. The accuracy was estimated using urine samples of cyclists as real samples and it was confirmed. The relative error of ≤5 % was considered significant in the method specificity study. The lead concentration mean for the cyclists was 3.79 μg L -1 in urine samples. As a result, the proposed method is a robust technique to quantify lead concentrations higher than 11.6 ng L -1 in urine samples.

  5. Investigation of Drug–Polymer Compatibility Using Chemometric-Assisted UV-Spectrophotometry

    Directory of Open Access Journals (Sweden)

    Amir Ibrahim Mohamed

    2017-01-01

    Full Text Available A simple chemometric-assisted UV-spectrophotometric method was used to study the compatibility of clindamycin hydrochloride (HC1 with two commonly used natural controlled-release polymers, alginate (Ag and chitosan (Ch. Standard mixtures containing 1:1, 1:2, and 1:0.5 w/w drug–polymer ratios were prepared and UV scanned. A calibration model was developed with partial least square (PLS regression analysis for each polymer separately. Then, test mixtures containing 1:1 w/w drug–polymer ratios with different sets of drug concentrations were prepared. These were UV scanned initially and after three and seven days of storage at 25 °C. Using the calibration model, the drug recovery percent was estimated and a decrease in concentration of 10% or more from initial concentration was considered to indicate instability. PLS models with PC3 (for Ag and PC2 (for Ch showed a good correlation between actual and found values with root mean square error of cross validation (RMSECV of 0.00284 and 0.01228, and calibration coefficient (R2 values of 0.996 and 0.942, respectively. The average drug recovery percent after three and seven days was 98.1 ± 2.9 and 95.4 ± 4.0 (for Ag, and 97.3 ± 2.1 and 91.4 ± 3.8 (for Ch, which suggests more drug compatibility with an Ag than a Ch polymer. Conventional techniques including DSC, XRD, FTIR, and in vitro minimum inhibitory concentration (MIC for (1:1 drug–polymer mixtures were also performed to confirm clindamycin compatibility with Ag and Ch polymers.

  6. Four Brazilian Maytenus salicifolia Reissek (Celastraceae groups studied by TLC and UV/Vis spectrophotometry

    Directory of Open Access Journals (Sweden)

    Frederico N. Valladão

    Full Text Available The great variety of angiosperms shows the need to development of botanical classification systems supported by phytochemistry, biochemistry and others. Recently, techniques of analysis used for the isolation and characterization of secondary metabolites have been employed as auxiliary quick and efficient methods for the identification and classification of plant species. M. salicifolia is popularly known in Brazil, as "small coffee" and decoct obtained from its fresh leaves is topically used to alleviate itches and other skins allergic symptoms. This work presents the use of TLC and UV/Vis spectrophotomety processes to be applied like an auxiliary method in botanical taxonomy. The results demonstrate that this process can be used in differentiation of the same genera species, and in the selection of chemical variations between individuals of the same species.

  7. Monitoring Pb in Aqueous Samples by Using Low Density Solvent on Air-Assisted Dispersive Liquid-Liquid Microextraction Coupled with UV-Vis Spectrophotometry.

    Science.gov (United States)

    Nejad, Mina Ghasemi; Faraji, Hakim; Moghimi, Ali

    2017-04-01

    In this study, AA-DLLME combined with UV-Vis spectrophotometry was developed for pre-concentration, microextraction and determination of lead in aqueous samples. Optimization of the independent variables was carried out according to chemometric methods in three steps. According to the screening and optimization study, 86 μL of 1-undecanol (extracting solvent), 12 times syringe pumps, pH 2.0, 0.00% of salt and 0.1% DDTP (chelating agent) were chosen as the optimum independent variables for microextraction and determination of lead. Under the optimized conditions, R = 0.9994, and linearity range was 0.01-100 µg mL -1 . LOD and LOQ were 3.4 and 11.6 ng mL -1 , respectively. The method was applied for analysis of real water samples, such as tap, mineral, river and waste water.

  8. Antioxidant study of quercetin and their metal complex and determination of stability constant by spectrophotometry method.

    Science.gov (United States)

    Ravichandran, R; Rajendran, M; Devapiriam, D

    2014-03-01

    Quercetin found chelate cadmium ions, scavenge free radicals produced by cadmium. Hence new complex, quercetin with cadmium was synthesised, and the synthesised complex structures were determined by UV-vis spectrophotometry, infrared spectroscopy, thermogravimetry and differential thermal analysis techniques (UV-vis, IR, TGA and DTA). The equilibrium stability constants of quercetin-cadmium complex were determined by Job's method. The determined stability constant value of quercetin-cadminum complex at pH 4.4 is 2.27×10(6) and at pH 7.4 is 7.80×10(6). It was found that the quercetin and cadmium ion form 1:1 complex in both pH 4.4 and pH 7.4. The structure of the compounds was elucidated on the basis of obtained results. Furthermore, the antioxidant activity of the free quercetin and quercetin-cadmium complexes were determined by DPPH and ABTS assays. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Simultaneous estimation of etodolac and thiocolchicoside in bulk and in tablet formulation by UV-spectrophotometry

    Directory of Open Access Journals (Sweden)

    Pandey Ramchandra

    2014-01-01

    Full Text Available Two simple, rapid and reproducible simultaneous equation and Q-Analysis UV-Spectrophotometric methods have been developed for simultaneous estimation of Etodolac (ETO and Thiocolchicoside (THC in combined tablet dosage form. The methods involved solving simultaneous equations and Q-value Analysis based on measurement of absorbance at wavelengths, 223 (λmax of ETO, 259.4 nm (λmax of THC and 236 nm (Iso-absorptive point. Linearity was found in the concentration range of 1-6 μg/mL and 4 - 24 μg/mL for ETO & THC respectively with coefficient correlation 0.9998 & 0.9992. The amount of drugs estimated by proposed methods are in excellent agreement with label claimed. Further-more, the methods were applied for the determination of ETO and THC in spiked human urine. The degradation behavior of ETO and THC was investigated under acid hydrolysis, alkali hydrolysis, photo and oxidative degradation. The samples subsequently generated were used for degradation studies using the developed method. Thiocolchicoside was found to degrade extensively under alkali hydrolysis and unaffected by other stress conditions while ETO was found to be stable in all stress conditions. The methods were validated according to ICH guidelines. The method, suitable for routine quality control, has been successfully applied to the determination of both drugs in commercial brands of tablets.

  10. Simple spectrophotometry method for the determination of sulfur dioxide in an alcohol-thionyl chloride reaction

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Jinjian, E-mail: jinjian.zheng@merck.com; Tan, Feng; Hartman, Robert

    2015-09-03

    Thionyl chloride is often used to convert alcohols into more reactive alkyl chloride, which can be easily converted to many compounds that are not possible from alcohols directly. One important reaction of alkyl chloride is nucleophilic substitution, which is typically conducted under basic conditions. Sulfur dioxide, the by-product from alcohol-thionyl chloride reactions, often reacts with alkyl chloride to form a sulfonyl acid impurity, resulting in yield loss. Therefore, the alkyl chloride is typically isolated to remove the by-products including sulfur dioxide. However, in our laboratory, the alkyl chloride formed from alcohol and thionyl chloride was found to be a potential mutagenic impurity, and isolation of this compound would require extensive safety measures. As a result, a flow-through process was developed, and the sulfur dioxide was purged using a combination of vacuum degassing and nitrogen gas sweeping. An analytical method that can quickly and accurately quantitate residual levels of sulfur dioxide in the reaction mixture is desired for in-process monitoring. We report here a simple ultraviolet (UV) spectrophotometry method for this measurement. This method takes advantage of the dramatic change in the UV absorbance of sulfur dioxide with respect to pH, which allows for accurate quantitation of sulfur dioxide in the presence of the strong UV-absorbing matrix. Each sample solution was prepared using 2 different diluents: 1) 50 mM ammonium acetate in methanol +1% v/v hydrochloric acid, pH 1.3, and 2) 50 mM ammonium acetate in methanol +1% glacial acetic acid, pH 4.0. The buffer solutions were carefully selected so that the UV absorbance of the sample matrix (excluding sulfur dioxide) at 276 nm remains constant. In the pH 1.3 buffer system, sulfur dioxide shows strong UV absorbance at 276 nm. Therefore, the UV absorbance of sample solution is the sum of sulfur dioxide and sample matrix. While in the pH 4.0 buffer system, sulfur dioxide has

  11. Evaluation of clinoptilolite for removal of ammoniacal nitrogen produced in aquaculture by Neutron activation analysis and UV-VIS spectrophotometry

    International Nuclear Information System (INIS)

    Bibiano C, L.; Iturbe G, J.L.; Lopez M, B.E.; Martinez M, V.

    1997-01-01

    In fish culture system, ammonia is excreted in the water as a metabolic by-product. In this work, sorption properties of clinoptilolite were determined and it was applied in culture of the rainbow trout Oncorhynchus mykiss for the removal of the ammoniacal nitrogen. The original clinoptilolite was treated with 1N NaCl solution from 24 to 192 h, for exchange NH 4 ions produced in fish culture. The content of Na in the clinoptilolite was determined by neutron activation analysis. The ammonium ion content in the exchange was analysed by UV-VIS spectrophotometry. Maximum uptake of sodium was reached between 24 and 48 hours at neutral pH with granules of the clinoptilolite from 14 to 24 mesh size. The adsorption capacity was from 3.28 to 6.8 mg of ammonium per gram of clinoptilolite. (Author)

  12. Application of response surface methodology for determination of methyl red in water samples by spectrophotometry method.

    Science.gov (United States)

    Khodadoust, Saeid; Ghaedi, Mehrorang

    2014-12-10

    In this study a rapid and effective method (dispersive liquid-liquid microextraction (DLLME)) was developed for extraction of methyl red (MR) prior to its determination by UV-Vis spectrophotometry. Influence variables on DLLME such as volume of chloroform (as extractant solvent) and methanol (as dispersive solvent), pH and ionic strength and extraction time were investigated. Then significant variables were optimized by using a Box-Behnken design (BBD) and desirability function (DF). The optimized conditions (100μL of chloroform, 1.3mL of ethanol, pH 4 and 4% (w/v) NaCl) resulted in a linear calibration graph in the range of 0.015-10.0mgmL(-1) of MR in initial solution with R(2)=0.995 (n=5). The limits of detection (LOD) and limit of quantification (LOQ) were 0.005 and 0.015mgmL(-1), respectively. Finally, the DLLME method was applied for determination of MR in different water samples with relative standard deviation (RSD) less than 5% (n=5). Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Application of response surface methodology for determination of methyl red in water samples by spectrophotometry method

    Science.gov (United States)

    Khodadoust, Saeid; Ghaedi, Mehrorang

    2014-12-01

    In this study a rapid and effective method (dispersive liquid-liquid microextraction (DLLME) was developed for extraction of methyl red (MR) prior to its determination by UV-Vis spectrophotometry. Influence variables on DLLME such as volume of chloroform (as extractant solvent) and methanol (as dispersive solvent), pH and ionic strength and extraction time were investigated. Then significant variables were optimized by using a Box-Behnken design (BBD) and desirability function (DF). The optimized conditions (100 μL of chloroform, 1.3 mL of ethanol, pH 4 and 4% (w/v) NaCl) resulted in a linear calibration graph in the range of 0.015-10.0 mg mL-1 of MR in initial solution with R2 = 0.995 (n = 5). The limits of detection (LOD) and limit of quantification (LOQ) were 0.005 and 0.015 mg mL-1, respectively. Finally, the DLLME method was applied for determination of MR in different water samples with relative standard deviation (RSD) less than 5% (n = 5).

  14. UV-visible scanning spectrophotometry and chemometric analysis as tools for carotenoids analysis in cassava genotypes (Manihot esculenta Crantz).

    Science.gov (United States)

    Moresco, Rodolfo; Uarrota, Virgílio G; Pereira, Aline; Tomazzoli, Maíra; Nunes, Eduardo da C; Martins Peruch, Luiz Augusto; Gazzola, Jussara; Costa, Christopher; Rocha, Miguel; Maraschin, Marcelo

    2015-12-01

    In this study, the metabolomics characterization focusing on the carotenoid composition of ten cassava (Manihot esculenta) genotypes cultivated in southern Brazil by UV-visible scanning spectrophotometry and reverse phase-high performance liquid chromatography was performed. Cassava roots rich in β-carotene are an important staple food for populations with risk of vitamin A deficiency. Cassava genotypes with high pro-vitamin A activity have been identified as a strategy to reduce the prevalence of deficiency of this vitamin. The data set was used for the construction of a descriptive model by chemometric analysis. The genotypes of yellow-fleshed roots were clustered by the higher concentrations of cis- β-carotene and lutein. Inversely, cream-fleshed roots genotypes were grouped precisely due to their lower concentrations of these pigments, as samples rich in lycopene (redfleshed) differed among the studied genotypes. The analytical approach (UV-Vis, HPLC, and chemometrics) used showed to be efficient for understanding the chemodiversity of cassava genotypes, allowing to classify them according to important features for human health and nutrition.

  15. A simple and cost-effective method, as an appropriate alternative for visible spectrophotometry: development of a dopamine biosensor.

    Science.gov (United States)

    Abbaspour, Abdolkarim; Khajehzadeh, Abdolreza; Ghaffarinejad, Ali

    2009-08-01

    In this study, a new, simple, fast and inexpensive method as an alternative to visible spectrophotometry is developed. In this method the cells containing the sample solution were scanned with a scanner, then the color of each cell was analyzed with software written in visual basic (VB 6) media to red, green and blue values. The cells were built by creating holes in the Plexiglas sheet. The dimensions of identical cells were examined by Cr (III) solution with known concentrations. The validity of this new method was studied by determination of dopamine (DA) without using any other reagent. The parameters which affect the system were optimized. The comparison between the current and traditional UV-Vis spectrophotometry methods was studied and the results revealed similar trends in both methods. The developed method was successfully applied to the determination of dopamine in serum and urine without using any pretreatment. Finally comparing the results obtained in the developed method showed that microwave irradiation of the solution can decrease the experimental time, increase sensitivity and improve the limit of detection.

  16. Preparation of Dry Extract of Mikania glomerata Sprengel (Guaco and Determination of Its Coumarin Levels by Spectrophotometry and HPLC-UV

    Directory of Open Access Journals (Sweden)

    Maria da Penha Henriques do Amaral

    2012-08-01

    Full Text Available Guaco (Mikania glomerata Sprengel syrup is one of the most popular herbal medicines used to treat the symptoms of asthmatic bronchitis, cough and hoarseness. The coumarin 2H-1-benzopyran-2-one, is one of the major constituents of Guaco and contributes to its pharmacological effects. The pharmaceutical capsule form of dry extract of Guaco is recommended by the Brazilian Program of Medicinal Plants and Herbal Medicines and used in primary health care. In order to identify a new protocol to obtain the raw material for Guaco capsule production we evaluated two methods, including a freeze-drying process (lyophilization and the spray-dryer technique, as well as the use of two adjuvants, Maltodextrins and Aerosil®, in different concentrations. The coumarin levels of the dried extracts were analyzed by UV-spectrophotometry and HPLC-UV/DAD. The adjuvant Aerosil® 8% showed better dry powder physical appearance. Lyophilization was observed to be the best process to obtain the dry extract of Guaco based on the measured coumarin levels.

  17. Use of Dispersive Liquid-Liquid Microextraction and UV-Vis Spectrophotometry for the Determination of Cadmium in Water Samples

    Directory of Open Access Journals (Sweden)

    J. Pérez-Outeiral

    2014-01-01

    Full Text Available A simple and inexpensive method for cadmium determination in water using dispersive liquid-liquid microextraction and ultraviolet-visible spectrophotometry was developed. In order to obtain the best experimental conditions, experimental design was applied. Calibration was made in the range of 10–100 μg/L, obtaining good linearity (R2 = 0.9947. The obtained limit of detection based on calibration curve was 8.5 μg/L. Intra- and interday repeatability were checked at two levels, obtaining relative standard deviation values from 9.0 to 13.3%. The enrichment factor had a value of 73. Metal interferences were also checked and tolerable limits were evaluated. Finally, the method was applied to cadmium determination in real spiked water samples. Therefore, the method showed potential applicability for cadmium determination in highly contaminated liquid samples.

  18. Improvement of precision method of spectrophotometry with inner standardization and its use in plutonium solutions analysis

    International Nuclear Information System (INIS)

    Stepanov, A.V.; Stepanov, D.A.; Nikitina, S.A.; Gogoleva, T.D.; Grigor'eva, M.G.; Bulyanitsa, L.S.; Panteleev, Yu.A.; Pevtsova, E.V.; Domkin, V.D.; Pen'kin, M.V.

    2006-01-01

    Precision method of spectrophotometry with inner standardization is used for analysis of pure Pu solutions. Improvement of the spectrophotometer and spectrophotometric method of analysis is done to decrease accidental constituent of relative error of the method. Influence of U, Np impurities and corrosion products on systematic constituent of error of the method, and effect of fluoride-ion on completeness of Pu oxidation in sample preparation are studied [ru

  19. Qualitative Aspects of UV-Vis Spectrophotometry of Beta-Carotene and Lycopene.

    Science.gov (United States)

    Tan, Barrie; Soderstrom, David N.

    1989-01-01

    Explores the structural behavior of polyenic pi systems such as isomerization and conjugation. Uses the simultaneous spectrophotometric analysis of a beta-carotene and lycopene mixture. Presents an empirical method to determine the number of double bonds in the polyenic carotenoid. (MVL)

  20. Four Brazilian Maytenus salicifolia Reissek (Celastraceae) groups studied by TLC and UV/Vis spectrophotometry

    OpenAIRE

    Valladão, Frederico N.; Miranda, Roqueline R. S.; Vale, Fernando H.; Valladão, Sara A.; Silva, Grácia D. F.; Duarte, Lucienir P.; Carvalho-Okano, Rita M.; Messias, Maria C. T. B.; Viera Filho, Sidney A.

    2009-01-01

    The great variety of angiosperms shows the need to development of botanical classification systems supported by phytochemistry, biochemistry and others. Recently, techniques of analysis used for the isolation and characterization of secondary metabolites have been employed as auxiliary quick and efficient methods for the identification and classification of plant species. M. salicifolia is popularly known in Brazil, as "small coffee" and decoct obtained from its fresh leaves is topically used...

  1. A general approach to quantification of hydroxycinnamic acid derivatives and flavones, flavonols, and their glycosides by UV spectrophotometry

    Science.gov (United States)

    A general method was developed for the quantification of hydroxycinnamic acid derivatives and flavones, flavonols, and their glycosides based on the UV molar relative response factors (MRRF) of the standards. Each of these phenolic compounds contains a cinnamoyl structure and has a maximum absorban...

  2. In situ, rapid, and temporally resolved measurements of cellulase adsorption onto lignocellulosic substrates by UV-vis spectrophotometry

    Science.gov (United States)

    Hao Liu; J. Y. Zhu; X. S. Chai

    2011-01-01

    This study demonstrated two in situ UV-vis spectrophotometric methods for rapid and temporally resolved measurements of cellulase adsorption onto cellulosic and lignocellulosic substrates during enzymatic hydrolysis. The cellulase protein absorption peak at 280 nm was used for quantification. The spectral interferences from light scattering by small fibers (fines) and...

  3. Ligand-protein conjugated quantification assay by UV spectrophotometry in 99mTc indirect labeling

    International Nuclear Information System (INIS)

    Basualdo, Daniel A.; Rabiller, Graciela; Poch, Carolina; El Tamer, Elias A.

    2009-01-01

    Objective: Quantify IgG-HYNIC conjugated for obtaining substitution ratio and as a chemical quality control for 99m Tc labeling of this immunoglobulin. Introduction: The Operational Guidance on Hospital Radiopharmacy by IAEA states that the procedures performed in a Radiopharmacy Laboratory fall into three operational levels. At present, Nuclear Medicine Centre of 'Hospital de Clinicas' has an operational level 2b which requires the preparation of radiopharmaceuticals from approved reagent kits and radionuclide generators, and labeling of autologous blood cells. Centre's goal is to reach an operational level 3a, which allows us to compounding radiopharmaceuticals from drugs and radionuclides for diagnosis; modification to existing commercial kits; related research and development. In approach of that goal, we addressed the optimization of conjugation of proteins and peptides with S-HYNIC so as to bring about the procedures involved. In this work, was conjugated nonspecific polyclonal immunoglobulin G (IgG) with S-HYNIC. Our interest was focused in calculate how many HYNIC groups were incorporated per IgG molecule so that in later stages can be obtained a correlate with labeling efficiency. Materials and methods: A sample of IgG-HYNIC conjugate of 0.2 ml was diluted in 4 ml of benzaldehyde o-sulfonic acid (1 mg / ml, 0.1 M NaAc, pH 4.7). The reaction was incubated at room temperature overnight in darkness. As a negative control took 0.2 ml of IgG-HYNIC conjugate in 4 ml of NaAc buffer 0.1 M. 3 ml of benzaldehyde o-sulfonic acid (1 mg / ml 0.1 M NaAc, pH 4.7) was used as blank. The absorption of the hydrazone was read at 343 nm. The hydrazine concentration was calculated using a molar extinction coefficient ε (343 nm) 17000 M-1cm-1. Results: Molar substitution ratio (MSR) was calculated. The MSR indicates the number of HYNIC groups incorporated in the IgG-HYNIC conjugate determined by the spectrophotometric assay. Conclusions: In labeling with a bifunctional

  4. Estratégias para aumento de sensibilidade em espectrofotometria UV-VIS Strategies to increase sensitivity in UV-VIS spectrophotometry

    Directory of Open Access Journals (Sweden)

    Fábio R. P. Rocha

    2004-10-01

    Full Text Available Spectrophotometry is one of the most widespread analytical techniques due to its simplicity, reliability, and low-cost instrumentation for both direct measurements and coupled to other techniques or processes such as chromatography, electrophoresis and flow analysis. However, the application is often limited by sensitivity. This article describes some advances that greatly improve the performance of spectrophotometric measurements, especially in order to increase sensitivity, including the employment of liquid-core waveguides and solid-phase spectrophotometry.

  5. Hydride generation coupled to microfunnel-assisted headspace liquid-phase microextraction for the determination of arsenic with UV-Vis spectrophotometry.

    Science.gov (United States)

    Hashemniaye-Torshizi, Reihaneh; Ashraf, Narges; Arbab-Zavar, Mohammad Hossein

    2014-12-01

    In this research, a microfunnel-assisted headspace liquid-phase microextraction technique has been used in combination with hydride generation to determine arsenic (As) by UV-Vis spectrophotometry. The method is based on the reduction of As to arsine (AsH3) in acidic media by sodium tetrahydroborate (NaBH4) followed by its subsequent reaction with silver diethyldithiocarbamate (AgDDC) to give an absorbing complex at 510 nm. The complexing reagent (AgDDC) has been dissolved in a 1:1 (by the volume ratio) mixture of chloroform/chlorobenzene microdroplet and exposed to the generated gaseous arsine via a reversed microfunnel in the headspace of the sample solution. Several operating parameters affecting the performance of the method have been examined and optimized. Acetonitrile solvent has been added to the working samples as a sensitivity enhancement agent. Under the optimized operating conditions, the detection limit has been measured to be 0.2 ng mL(-1) (based on 3sb/m criterion, n b = 8), and the calibration curve was linear in the range of 0.5-12 ng mL(-1). The relative standard deviation for eight replicate measurements was 1.9 %. Also, the effects of several potential interferences have been studied. The accuracy of the method was validated through the analysis of JR-1 geological standard reference material. The method has been successfully applied for the determination of arsenic in raw and spiked soft drink and water samples with the recoveries that ranged from 91 to 106 %.

  6. Ionic liquid-based single-drop microextraction followed by liquid chromatography-ultraviolet spectrophotometry detection to determine typical UV filters in surface water samples.

    Science.gov (United States)

    Vidal, Lorena; Chisvert, Alberto; Canals, Antonio; Salvador, Amparo

    2010-04-15

    A user-friendly and inexpensive ionic liquid-based single-drop microextraction (IL-SDME) procedure has been developed to preconcentrate trace amounts of six typical UV filters extensively used in cosmetic products (i.e., 2-hydroxy-4-methoxybenzophenone, isoamyl 4-methoxycinnamate, 3-(4'-methylbenzylidene)camphor, 2-ethylhexyl 2-cyano-3,3-diphenylacrylate, 2-ethylhexyl 4-dimethylaminobenzoate and 2-ethylhexyl 4-methoxycinnamate) from surface water samples prior to analysis by liquid chromatography-ultraviolet spectrophotometry detection (LC-UV). A two-stage multivariate optimization approach was developed by means of a Plackett-Burman design for screening and selecting the significant variables involved in the SDME procedure, which were later optimized by means of a circumscribed central composite design. The studied variables were drop volume, sample volume, agitation speed, ionic strength, extraction time and ethanol quantity. Owing to particularities, ionic liquid type and pH of the sample were optimized separately. Under optimized experimental conditions (i.e., 10 microL of 1-hexyl-3-methylimidazolium hexafluorophosphate, 20 mL of sample containing 1% (v/v) ethanol and NaCl free adjusted to pH 2, 37 min extraction time and 1300 rpm agitation speed) enrichment factors up to ca. 100-fold were obtained depending on the target analyte. The method gave good levels of repeatability with relative standard deviations varying between 2.8 and 8.8% (n=6). Limits of detection were found in the low microg L(-1) range, varying between 0.06 and 3.0 microg L(-1) depending on the target analyte. Recovery studies from different types of surface water samples collected during the winter period, which were analysed and confirmed free of all target analytes, ranged between 92 and 115%, showing that the matrix had a negligible effect upon extraction. Finally, the proposed method was applied to the analysis of different water samples (taken from two beaches, two swimming pools and a

  7. An Overview of Analytical Determination of Diltiazem, Cimetidine, Ranitidine, and Famotidine by UV Spectrophotometry and HPLC Technique

    Directory of Open Access Journals (Sweden)

    Nighat Shafi

    2013-01-01

    Full Text Available This review article recapitulates the analytical methods for the quantitative determinations of diltiazem and three H2 receptor antagonists (cimetidine, ranitidine, and famotidine by one of the spectroscopic technique (UV spectrophotometery and separation technique such as high-performance liquid chromatography (HPLC. The clinical and pharmaceutical analysis of these drugs requires effective analytical procedures for quality control, pharmaceutical dosage formulations, and biological fluids. An extensive survey of the literature published in various analytical and pharmaceutical chemistry-related journals has been compiled in its review. A synopsis of reported spectrophotometric and high-performance liquid chromatographic methods for individual drug is integrated. This appraisal illustrates that majority of the HPLC methods reviewed are based on the quantitative analysis of drugs in biological fluids, and they are appropriate for therapeutic drug monitoring purpose.

  8. Evaluation of the acidity constants of the 4-hidroxy-5-6salicylideneamino9-2-7-naphthalenedisulfonic acid (Azomethine-H) using UV?vis spectrophotometry

    Science.gov (United States)

    Alarcón-Angeles, G.; Corona-Avendaño, S.; Rojas-Hernández, A.; Romero-Romo, M. A.; Ramírez-Silva, M. T.

    2005-01-01

    The time stability of the azomethine-H species was determined not to be better than 10 min in the absence of oxygen and light, however under phosphate buffered conditions the azomethine-H species remained stable for longer periods, as indicated by the spectrophotometric behaviour. Nevertheless, the analysis time still exceeded the stability allowance. Therefore, the determination of the acidity constants of the Azomethine-H species was studied by means of UV-vis spectrophotometry in buffered media by means of the point-by-point analysis and data processing with SQUAD to refine the resulting constants, which were: p Ka1=3.39, p Ka2 7.36 and p Ka3 8.73. The latter were associated to the corresponding acid-base equilibria of the amine and hydroxy groups constituting the molecule.

  9. Simultaneous determination of polysaccharides and 21 nucleosides and amino acids in different tissues of Salvia miltiorrhiza from different areas by UV-visible spectrophotometry and UHPLC with triple quadrupole MS/MS.

    Science.gov (United States)

    Xiang, Xiang; Sha, Xiuxiu; Su, Shulan; Zhu, Zhenhua; Guo, Sheng; Yan, Hui; Qian, Dawei; Duan, Jin-Ao

    2018-03-01

    Salvia miltiorrhiza, a traditional Chinese medicine, is a widely used herbal medicine to treat cardiovascular and cerebrovascular diseases. In this study, ultraviolet (UV)-visible spectrophotometry and ultra-high performance liquid chromatography with triple quadrupole tandem mass spectrometry analytical methods were used for rapid quantification of polysaccharides and 21 nucleosides and amino acids in S. miltiorrhiza to determine 17 samples of different tissues from different areas. Based on the total contents, hierarchical clustering analysis and principal components analysis were performed to classify these samples. The established methods were validated with good linearity, precision, repeatability, stability, and recovery. Chemical analysis revealed a higher content of total analytes in the sample of inflorescence from Nanjing (34.17 mg/g), sample of root and rhizome from Shaanxi (34.13 mg/g) and sample of stem and leaf from Nanjing (31.14 mg/g), respectively, indicating that root and rhizome from Shaanxi and the aerial parts from Nanjing exhibited the highest quality due to their highest content. In addition, contents of nucleosides and amino acids in the aerial parts (14.67 mg/g) were much higher than that in roots and rhizomes (9.17 mg/g). This study suggested that UV-visible spectrophotometry and ultra-high performance liquid chromatography with triple quadrupole tandem mass spectrometry are effective techniques to analyze polysaccharides, nucleosides, and amino acids in plants, and they provided valuable information for the development and utilization value of the aerial parts of S. miltiorrhiza. This analysis would also provide useful information for the quality control of S. miltiorrhiza. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Atomic-fluorescence spectrophotometry

    International Nuclear Information System (INIS)

    Bakhturova, N.F.; Yudelevich, I.G.

    1975-01-01

    Atomic-fluorescence spectrophotometry, a comparatively new method for the analysis of trace quantities, has developed rapidly in the past ten years. Theoretical and experimental studies by many workers have shown that atomic-fluorescence spectrophotometry (AFS) is capable of achieving a better limit than atomic absorption for a large number of elements. The present review examines briefly the principles of atomic-fluorescence spectrophotometry and the types of fluorescent transition. The excitation sources, flame and nonflame atomizers, used in AFS are described. The limits of detection achieved up to the present, using flame and nonflame methods of atomization are given

  11. UV-Vis spectrophotometry of quinone flow battery electrolyte for in situ monitoring and improved electrochemical modeling of potential and quinhydrone formation.

    Science.gov (United States)

    Tong, Liuchuan; Chen, Qing; Wong, Andrew A; Gómez-Bombarelli, Rafael; Aspuru-Guzik, Alán; Gordon, Roy G; Aziz, Michael J

    2017-12-06

    Quinone-based aqueous flow batteries provide a potential opportunity for large-scale, low-cost energy storage due to their composition from earth abundant elements, high aqueous solubility, reversible redox kinetics and their chemical tunability such as reduction potential. In an operating flow battery utilizing 9,10-anthraquinone-2,7-disulfonic acid, the aggregation of an oxidized quinone and a reduced hydroquinone to form a quinhydrone dimer causes significant variations from ideal solution behavior and of optical absorption from the Beer-Lambert law. We utilize in situ UV-Vis spectrophotometry to establish (a), quinone, hydroquinone and quinhydrone molar attenuation profiles and (b), an equilibrium constant for formation of the quinhydrone dimer (K QHQ ) ∼ 80 M -1 . We use the molar optical attenuation profiles to identify the total molecular concentration and state of charge at arbitrary mixtures of quinone and hydroquinone. We report density functional theory calculations to support the quinhydrone UV-Vis measurements and to provide insight into the dimerization conformations. We instrument a quinone-bromine flow battery with a Pd-H reference electrode in order to demonstrate how complexation in both the negative (quinone) and positive (bromine) electrolytes directly impacts measured half-cell and full-cell voltages. This work shows how accounting for electrolyte complexation improves the accuracy of electrochemical modeling of flow battery electrolytes.

  12. Determination of losartan potassium, quinapril hydrochloride and hydrochlorothiazide in pharmaceutical preparations using derivative spectrophotometry and chromatographic-densitometric method.

    Science.gov (United States)

    Stolarczyk, Mariusz; Maślanka, Anna; Apola, Anna; Krzek, Jan

    2013-01-01

    Two methods, spectrophotometric and chromatographic-densitometric ones, were developed for determination of losartan potassium, quinapril hydrochloride and hydrochlorothiazide in pharmaceutical preparations. Spectrophotometric method involved derivative spectrophotometry and zero order spectrophotometry. The measurements were carried out at lambda = 224.0 nm for quinapril, lambda = 261.0 nm for hydrochlorothiazide and lambda = 270.0 nm for losartan when the derivative spectrophotometry was applied and lambda = 317.0 nm when zero order spectrophotometry was applied for the determination of hydrochlorothiazide. In chromatographic-densitometric studies high performance thin layer chromatography (HPTLC) plates were used as stationary phase and a mixture of solvents n-butanol : acetic acid : water (15 : 5 : 1, v/v/v) as mobile phase. Under the established conditions good resolution of examined constituents was obtained. Retardation factor for quinapril hydrochloride was R(f) - 0.70, for losartan potassium R(f) - 0.85 and for hydrochlorothiazide R(f) - 0.78. The developed methods are characterized by high sensitivity and accuracy. For quantitative analysis, densitometric measurements were carried out at lambda = 218.0 nm for quinapril, lambda = 275.0 nm for hydrochlorothiazide and = 232.0 nm for losartan.

  13. Photochemical reaction monitoring by ultra-violet spectrophotometry.

    Science.gov (United States)

    Roig, B; Touraud, E; Thomas, O

    2002-11-01

    Within the framework of the monitoring of the trichloroacetylchloride (TCAC) photosynthesis, ultra-violet (UV) spectrophotometry is proposed as a simple and rapid tool allowing, in real time, the control of the process efficiency. A good correlation has been obtained between the results acquired by this alternative method and the standard gas chromatography.

  14. Redox equilibrium of U4+/U3+ in molten NaCl-2CsCl by UV-Vis spectrophotometry and cyclic voltammetry

    International Nuclear Information System (INIS)

    Nagai, Takayuki; Uehara, Akihiro; Fujii, Toshiyuki; Shirai, Osamu; Yamana, Hajimu; Sato, Nobuaki

    2005-01-01

    In order to investigate the redox equilibrium of uranium ions in molten NaCl-2CsCl, UV-Vis absorption spectro-photometry measurements were performed for U 4+ and U 3+ in molten NaCl-2CsCl at 923 K under simultaneous electrolytic control of their ratio. Prominent absorption bands at 480 and 570 nm were assigned to U 3+ , and their molar absorptivities were determined to be 1,260±42 and 963±32 mol -1 ·l·cm -1 respectively. From the dependence of the rest potential of the melt on the spectrophotometrically determined ratio of [U 4+ ]/[U 3+ ], the standard redox potential of the couple U 4+ /U 3+ at 923 K was determined to be -1.481±0.004 V vs. Cl 2 /Cl - . Cyclic voltammetry measurements were carried out for the couple U 4+ /U 3+ , and the results agreed well with this standard redox potential value. By the results of cyclic voltammetry, a temperature dependence of the standard redox potential was found to be -2.094+6.639 x 10 -4 T (T=823-923K). (author)

  15. Feasibility of Using Fluorescence Spectrophotometry to Develop a Sensitive Dye Immersion Method for Container Closure Integrity Testing of Prefilled Syringes.

    Science.gov (United States)

    Lu, Xujin; Lloyd, David K; Klohr, Steven E

    2016-01-01

    A feasibility study was conducted for a sensitive and robust dye immersion method for the measurement of container closure integrity of unopened prefilled syringes using fluorescence spectrophotometry as the detection method. A Varian Cary Eclipse spectrofluorometer was used with a custom-made sample holder to position the intact syringe in the sample compartment for fluorescence measurements. Methylene blue solution was initially evaluated as the fluorophore in a syringe with excitation at 607 nm and emission at 682 nm, which generated a limit of detection of 0.05 μg/mL. Further studies were conducted using rhodamine 123, a dye with stronger fluorescence. Using 480 nm excitation and 525 nm emission, the dye in the syringe could be easily detected at levels as low as 0.001 μg/mL. The relative standard deviation for 10 measurements of a sample of 0.005 μg/mL (with repositioning of the syringe after each measurement) was less than 1.1%. A number of operational parameters were optimized, including the photomultiplier tube voltage, excitation, and emission slit widths. The specificity of the testing was challenged by using marketed drug products and a protein sample, which showed no interference to the rhodamine detection. Results obtained from this study demonstrated that using rhodamine 123 for container closure integrity testing with in-situ (in-syringe) fluorescence measurements significantly enhanced the sensitivity and robustness of the testing and effectively overcame limitations of the traditional methylene blue method with visual or UV-visible absorption detection. Ensuring container closure integrity of injectable pharmaceutical products is necessary to maintain quality throughout the shelf life of a sterile drug product. Container closure integrity testing has routinely been used to evaluate closure integrity during product development and production line qualification of prefilled syringes, vials, and devices. However, container closure integrity testing

  16. Comparison of Ho and Y complexation data obtained by electromigration methods, potentiometry and spectrophotometry

    International Nuclear Information System (INIS)

    Vinsova, H.; Koudelkova, M.; Ernestova, M.; Jedinakova-Krizova, V.

    2003-01-01

    Many of holmium and yttrium complex compounds of both organic and inorganic origin have been studied recently from the point of view of their radiopharmaceutical behavior. Complexes with Ho-166 and Y-90 can be either directly used as pharmaceutical preparations or they can be applied in a conjugate form with selected monoclonal antibody. Appropriate bifunctional chelation agents are necessary in the latter case for indirect binding of monoclonal antibody and selected radionuclide. Our present study has been focused on the characterization of radionuclide (metal) - ligand interaction using various analytical methods. Electromigration methods (capillary electrophoresis, capillary isotachophoresis), potentiometric titration and spectrophotometry have been tested from the point of view of their potential to determine conditional stability constants of holmium and yttrium complexes. A principle of an isotachophoretic determination of stability constants is based on the linear relation between logarithms of stability constant and a reduction of a zone of complex. For the calculation of thermodynamic constants using potentiometry it was necessary at first to determine the protonation constants of acid. Those were calculated using the computer program LETAGROP Etitr from data obtained by potentiometric acid-base titration. Consequently, the titration curves of holmium and yttrium with studied ligands and protonation constants of corresponding acid were applied for the calculation of metal-ligand stability constants. Spectrophotometric determination of stability constants of selected systems was based on the titration of holmium and yttrium nitrate solutions by Arsenazo III following by the titration of metal-Arsenazo III complex by selected ligand. Data obtained have been evaluated using the computation program OPIUM. Results obtained by all analytical methods tested in this study have been compared. It was found that direct potentiometric titration technique could not be

  17. Europium determination in oxide and oxysulfide luminophors and their wastes by the method of direct and derivative spectrophotometry

    International Nuclear Information System (INIS)

    Mishchenko, V.T.; Aleksandrova, N.N.

    1989-01-01

    Spectrophotometric methods for europium determination in luminophors are proposed. Application of standard and derivative spectrophotometry allows one to determine europium in oxide and oxysulfide luminophors, their wastes and raffinates produced during waste reprocessing quite accurately and reliably. When determining Eu 2 O 3 (Eu 2 O 2 S) mass shares within 4-8 % limits absolute deviation from the mean result makes up to more than ± 0.2 %, relative standard deviation does not exceed 0.02

  18. Comparative studies of method for determining total mercury in fish. Dithizone and flameless atomic absorption spectrophotometry techniques

    International Nuclear Information System (INIS)

    Protasowicki, M.; Ociepa, A.; Chodyniecki, A.

    1977-01-01

    Two methods for determining total mercury in fish were compared: the dithizone and flameless atomic absorption spectrophotometry techniques. The studies involved determination of recovery when 1μg of mercury as solutions of HgCl 2 or CH 3 HgC were added to each sample of herring flesh. Mean recoveries in the dithizone method were found to be 91.4+-7.47% and 90.25+-4.73% for the two solutions respectively, while the recoveries obtained with the flameless atomic absorption spectrophotometry were 95.00+-9.13% and 98.70+-7.14%, respectively. Both techniques were used to determine the mercury content in the same herring flesh sample. The first technique showed the content of 0.050+-0.018μg Hg g -1 while the result obtained with the other one was 0.062+-0.013μg Hg g -1 . The statistical treatment of the results obtained showed no difference between the two techniques, the significance level being α=0.05. Therefore, the results obtained with the dithizone method are comparable with those obtained with the flameless atomic absorption spectrophotometry for mercury contents of the magnitude order of 0.050 ug.g -1 . (author)

  19. Total phytosterol content in drug materials and extracts from roots of Acanthospermum hispidum by UV-VIS spectrophotometry

    Directory of Open Access Journals (Sweden)

    Larissa B. D. C. Araújo

    Full Text Available Acanthospermum hispidum DC., Asteraceae, is widely used in folk medicine in Brazil to treat respiratory diseases; this biological property has been attributed to its phytosterol content. This study evaluated the spectrophotometric assay method to quantify the total phytosterol content in raw materials and extracts from roots of A. hispidum. The procedure was based on the quantification at 625 nm after the Liebermann-Burchard reaction. The method was evaluated for linearity, repeatability, intermediate precision, accuracy and robustness. The date indicated that the procedure is a valid analytical tool for materials and herbal derivatives from A. hispidum.

  20. Ultrasensitive, simple and solvent-free micro-assay for determining sulphite preservatives (E220-228) in foods by HS-SDME and UV-vis micro-spectrophotometry.

    Science.gov (United States)

    Gómez-Otero, E; Costas, M; Lavilla, I; Bendicho, C

    2014-03-01

    A new method based on headspace single-drop microextraction in combination with UV-vis micro-spectrophotometry has been developed for the ultrasensitive determination of banned sulphite preservatives (E220-228) in fruits and vegetables. Sample acidification was used for SO2 generation, which is collected onto a 5,5'-dithiobis-(2-nitrobenzoic acid) microdrop for spectrophotometric measurement. A careful study of this reaction was necessary, including conditions for SO2 generation from different sulphating salts, drop pH, 5,5'-dithiobis-(2-nitrobenzoic acid) concentration and potential interference effects. Variables influencing mass transfer (stirring, sample volume and addition of salt) and microextraction time were also studied. A simple sulphite extraction was carried out, and problems caused by oxidation during the extraction process were addressed. A high enrichment factor (380) allows the determination of low levels of free SO2 in fruits and vegetables (limit of detection 0.06 μg g(-1), limit of quantification 0.2 μg g(-1)) with an adequate precision (repeatability, relative standard deviation 5 %). In addition, the sulphiting process was studied through the monitoring of residual SO2 in a vegetal sample, thus showing the importance of a sensitive tool for SO2 detection at low levels.

  1. Determination of trace inorganic mercury species in water samples by cloud point extraction and UV-vis spectrophotometry.

    Science.gov (United States)

    Ulusoy, Halil Ibrahim

    2014-01-01

    A new micelle-mediated extraction method was developed for preconcentration of ultratrace Hg(II) ions prior to spectrophotometric determination. 2-(2'-Thiazolylazo)-p-cresol (TAC) and Ponpe 7.5 were used as the chelating agent and nonionic surfactant, respectively. Hg(II) ions form a hydrophobic complex with TAC in a micelle medium. The main factors affecting cloud point extraction efficiency, such as pH of the medium, concentrations of TAC and Ponpe 7.5, and equilibration temperature and time, were investigated in detail. An overall preconcentration factor of 33.3 was obtained upon preconcentration of a 50 mL sample. The LOD obtained under the optimal conditions was 0.86 microg/L, and the RSD for five replicate measurements of 100 microg/L Hg(II) was 3.12%. The method was successfully applied to the determination of Hg in environmental water samples.

  2. Kinetic evaluation of black tea color index and determination of factors, which influence its by UV/Vis spectrophotometry

    International Nuclear Information System (INIS)

    Nikpour, A. R.; Bahmaei, H.; Samimei, H.; Sohrabi, M. R.

    2002-01-01

    The tea is the most important product that is widely consumed in the world. Its color is one of the basic parameter. It is known that the best color of an infusion of black tea is a bright orange-red color. [1] Rates of color extraction and amount of its extract are also important in tea quality. Various methods have been reported for this purpose which are mainly time consumable. In this research, absorbance at 480 nm is used (instate of total spectrum) as a fast and convent color index. The experiments have shown that this proposed method have good results. Effects of various factors on the color of an infusion of black tea was investigated; including: leaf size, temperature, ph, total dissolved solid and water hardness. Finally, its kinetic diagrams were determined which give

  3. Garnacha Tintorera-based sweet wines: chromatic properties and global phenolic composition by means of UV-Vis spectrophotometry.

    Science.gov (United States)

    Figueiredo-González, M; Cancho-Grande, B; Simal-Gándara, J

    2013-09-01

    Valdeorras (the N.W. corner of Spain) wants to promote the production and marketing of new sweet wines. The present work represents the first study on sweet wines manufactured with red grapes Vitis vinifera L. Garnacha Tintorera, a teinturier cultivar. Two different red sweet wines were elaborated: the first one was made with dried grapes; Vitis vinifera L. Garnacha Tintorera has excellent potential to produce wines from raisined grapes; the second one, a fortified sweet wine aged in oak barrels. Different red Garnacha Tintorera-based wines (a dry base wine, GBW; a naturally sweet wine, GNSW; and a fortified sweet wine, GFSW) were characterized. Chromatic characteristics and phenolic compounds were established by spectrophotometric methods in order to assess the technology of Garnacha Tintorera-based sweet wines. High molecular weight brown polymers, produced during the grape drying process and isolated from sweet wines by the dialysis process, were responsible for the brown colour of sweet wines. As a consequence, yellowness of sweet wines was also higher which was confirmed by colorimetric indexes. With respect to phenolic content, GFSW presented the lowest content because the maceration-alcoholic fermentation was stopped through the addition of alcohol before the diffusion of red pigments from skins to must was complete. GNSW presented the highest phenolic content due to the concentration effect resulting from evaporation of water from the grapes. Anthocyanins of sweet wines were polymerised in great extent. The percentage of polymerised tannins was sufficient to guarantee the aging process of sweet wines. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. A simple and efficient ultrasonic-assisted extraction procedure combined with UV-Vis spectrophotometry for the pre-concentration and determination of folic acid (vitamin B9) in various sample matrices.

    Science.gov (United States)

    Gürkan, Ramazan; Altunay, Nail

    2016-07-01

    A simple and efficient ultrasonic-assisted extraction (UAE) procedure has been proposed for the pre-concentration of (2S)-2-[(4-{[(2-amino-4-hydroxypteridin-yl)methyl]amino}phenyl)formamido]pentanedioic acid (folic acid) in vegetables, pharmaceuticals and foods prior to determination at 540 nm using UV-Vis spectrophotometry. The method is based on hydrophobic ternary complex formation of folic acid with silver ions in the presence of cetyltrimethylammonium bromide (CTAB) as a sensitivity enhancer counter ion at pH 7.0, and then extraction into a micellar phase of polyethylene glycol monoalkyl ether (Genapol X-080). The impacts on the extraction efficiency and complex formation of analytical parameters such as sample pH, concentration of silver, concentration of surfactants and extraction time, ultrasonic time and sample volume, were investigated and optimised in detail. The matrix effect on the pre-concentration and determination of folic acid was investigated, and it was observed that the proposed method was highly selective against possible matrix co-extractives. Under optimised conditions, a good linear relationship between the analytical signal and folic acid concentration was obtained in the range of 0.6-180 μg l(-1) with a detection limit of 0.19 μg l(-1) and quantification limit of 0.63 μg l(-1). The applicability was evaluated using samples fortified at different concentration levels, and recoveries higher than 94.1% were obtained. The precision as the percent relative standard deviation (RSD%) was in range of 2.5-3.8% (10 and 40 μg l(-1), n = 5). The proposed method was validated by analysis of two standard reference materials (SRMs) and various real samples, and satisfactory results were obtained.

  5. Derivative spectrophotometry of cobalt alloys

    International Nuclear Information System (INIS)

    Spitsyn, P.K.

    1985-01-01

    The method of derivative spectrophotometry is briefly described, and derivative absorption spectra are presented for samarium, cobalt, and commercial Sm-Co alloys. It is shown that the use of derivative spectrophotometry not only improves the accuracy and selectivity of element determinations but also simplifies the analysis of alloys. Results of a statistical evaluation of the metrological characteristics of the analytical procedure described here are presented. 8 references

  6. UV/VIS spektrofotometrie a možnosti jejího využití v rámci vzdělávání učitelů chemie

    OpenAIRE

    Hejsková, Veronika

    2016-01-01

    This master's thesis discusses the use of UV/VIS spectrophotometry in chemistry teacher education. Optical methods principles are described in theoretical part of the thesis, and. the main part is dedicated to UV-VIS spectrophotometry. Tasks for quantifying and qualifying substances determination are described in experimental part. Educational tasks are described in a way so that chemistry teachers could use for instructions.

  7. Simultaneous Preconcentration and Determination of Brilliant Blue and Sunset Yellow in Foodstuffs by Solid-Phase Extraction Combined UV-Vis Spectrophotometry.

    Science.gov (United States)

    Bişgin, Abdullah Taner

    2018-05-29

    Background: Brilliant Blue and Sunset Yellow, two highly water-soluble synthetic food dyes, are the most popular food dyes used and consumed. Although they are not highly toxic, some health problems can be observed when excessive amounts of food products containing these dyes are consumed. Objectives: The aim of the study was to develop a simultaneous UV-Vis combined solid-phase extraction method, based on the adsorption onto Amberlite XAD-8 resin, for determination of Brilliant Blue and Sunset Yellow dyes. Methods: Sample solution was poured into the reservoir of the column and permitted to gravitationally pass through the column at 2 mL/min flow rate. Adsorbed dyes were eluted to 5 mL of final volume with 1 mol/L HNO₃ in ethanol solution by applying a 2 mL/min flow rate. Dye concentrations of the solution were determined at 483 and 630 nm for Sunset Yellow and Brilliant Blue, respectively. Results: The detection limits of the method for Brilliant Blue and Sunset Yellow were determined as 0.13 and 0.66 ng/mL, respectively. Preconcentration factor was 80. Brilliant Blue contents of real food samples were found to be between 11 and 240 μg/g. Sunset Yellow concentrations of foodstuffs were determined to be between 19 and 331 μg/g. Conclusions: Economical, effective, and simple simultaneous determination of Brilliant Blue and Sunset Yellow was achieved by using a solid-phase extraction combined UV-Vis spectrometry method. Highlights: The method is applicable and suitable for routine analysis in quality control laboratories without the need for expert personnel and high operational costs because the instrumentation is simple and inexpensive.

  8. Spectrophotometry (by Barbara Sawrey and Gabriele Wienhausen)

    Science.gov (United States)

    Pringle, David L.

    1998-08-01

    Science Media: San Diego, 1997. 1-10 copies, 99 each; 11-20 copies, 69 each; 21+ copies, $49 each. (Note: CD operates with both Mac and PC.) Spectrophotometry is an interactive CD-ROM which introduces the basics of UV-visible spectrophotometry with some mention of infrared and other forms of spectrophotometry. A Macintosh System 7.5 or higher, CPU 68040 or Power PC processor, 6 megabytes of free RAM, 2.6 megabytes of free disk space, and 4X CD-ROM or faster are required.

  9. Assessment of cosmetic ingredients in the in vitro reconstructed human epidermis test method EpiSkin™ using HPLC/UPLC-spectrophotometry in the MTT-reduction assay.

    Science.gov (United States)

    Alépée, N; Hibatallah, J; Klaric, M; Mewes, K R; Pfannenbecker, U; McNamee, P

    2016-06-01

    Cosmetics Europe recently established HPLC/UPLC-spectrophotometry as a suitable alternative endpoint detection system for measurement of formazan in the MTT-reduction assay of reconstructed human tissue test methods irrespective of the test system involved. This addressed a known limitation for such test methods that use optical density for measurement of formazan and may be incompatible for evaluation of strong MTT reducer and/or coloured chemicals. To build on the original project, Cosmetics Europe has undertaken a second study that focuses on evaluation of chemicals with functionalities relevant to cosmetic products. Such chemicals were primarily identified from the Scientific Committee on Consumer Safety (SCCS) 2010 memorandum (addendum) on the in vitro test EpiSkin™ for skin irritation testing. Fifty test items were evaluated in which both standard photometry and HPLC/UPLC-spectrophotometry were used for endpoint detection. The results obtained in this study: 1) provide further support for Within Laboratory Reproducibility of HPLC-UPLC-spectrophotometry for measurement of formazan; 2) demonstrate, through use a case study with Basazol C Blue pr. 8056, that HPLC/UPLC-spectrophotometry enables determination of an in vitro classification even when this is not possible using standard photometry and 3) addresses the question raised by SCCS in their 2010 memorandum (addendum) to consider an endpoint detection system not involving optical density quantification in in vitro reconstructed human epidermis skin irritation test methods. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Inter-laboratory verification of European pharmacopoeia monograph on derivative spectrophotometry method and its application for chitosan hydrochloride.

    Science.gov (United States)

    Marković, Bojan; Ignjatović, Janko; Vujadinović, Mirjana; Savić, Vedrana; Vladimirov, Sote; Karljiković-Rajić, Katarina

    2015-01-01

    Inter-laboratory verification of European pharmacopoeia (EP) monograph on derivative spectrophotometry (DS) method and its application for chitosan hydrochloride was carried out on two generation of instruments (earlier GBC Cintra 20 and current technology TS Evolution 300). Instruments operate with different versions of Savitzky-Golay algorithm and modes of generating digital derivative spectra. For resolution power parameter, defined as the amplitude ratio A/B in DS method EP monograph, comparable results were obtained only with algorithm's parameters smoothing points (SP) 7 and the 2nd degree polynomial and those provided corresponding data with other two modes on TS Evolution 300 Medium digital indirect and Medium digital direct. Using quoted algorithm's parameters, the differences in percentages between the amplitude ratio A/B averages, were within accepted criteria (±3%) for assay of drug product for method transfer. The deviation of 1.76% for the degree of deacetylation assessment of chitosan hydrochloride, determined on two instruments, (amplitude (1)D202; the 2nd degree polynomial and SP 9 in Savitzky-Golay algorithm), was acceptable, since it was within allowed criteria (±2%) for assay deviation of drug substance, for method transfer in pharmaceutical analyses. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Single-laboratory evaluation of SW-846 Methods 7090/7091 determination of beryllium by flame and furnace atomic absorption spectrophotometry. Summary report January-August 1987

    International Nuclear Information System (INIS)

    Hodge, V.F.; Darby, D.A.; Thompson, W.E.; Jones, C.L.

    1988-02-01

    The results of a single-laboratory study of the Determination of Beryllium by Flame and Furnace Atomic Absorption Spectrophotometry, are described. The study examined the application of these two powerful beryllium detection methods to the analysis of selected liquid and solid samples after digestion by appropriate SW-846 methods. Method performance data including detection limits, optimum concentration ranges (linearity), spike recoveries, interferences, precision, accuracy, and optimum operating parameters are presented and discussed

  12. Derivative Quotient Spectrophotometry and an Eco-Friendly Micellar Chromatographic Approach with Time-Programmed UV-Detection for the Separation of Two Fluoroquinolones and Phenazopyridine

    Science.gov (United States)

    Tolba, Manar M.; Salim, Mohamed M.

    2016-01-01

    In this study, two analytical approaches were exploited for the resolution of binary mixtures of ciprofloxacin HCl (CIP) or norfloxacin (NOR) and phenazopyridine HCl (PHZ). In the first approach, the amplitudes of the first derivative of the ratio spectra were measured at 267 or 287 nm for CIP and at 268 or 291 nm for NOR. PHZ could be directly determined in the presence of CIP or NOR at 405 nm. The calibration graphs were rectilinear over the ranges of 1.0–16.0 µg/mL for CIP or NOR and 1.0–10.0 µg/mL for PHZ. In the second approach, an accurate, reliable and environmentally nontoxic micellar liquid chromatographic (MLC) method was developed. A good chromatographic separation was achieved using a 150 mm × 4.6 mm i.d., 5 µm particle size Spherisorb ODS-2 column. Eco-friendly mobile phase containing 0.12 M sodium dodecyl sulphate, 0.3% triethylamine and 6% n-butanol in 0.02 M orthophosphoric acid of pH 3.0 was pumped at a flow rate of 1 mL/min. Time programmed UV-detection was applied to allow sensitive determination of the studied drugs. The analytes were eluted without interferences in <10 min. Methocarbamol was used as an internal standard. The MLC method was found to be rectilinear over the concentration range of 0.5–20.0 μg/mL for CIP, NOR or PHZ. These optimized and validated methods were successfully applied for the simultaneous analysis of the studied drugs in their synthetic mixtures and co-formulated tablets. Moreover, the second method was further extended to the determination of these drugs in human urine with direct injection and without any pretreatment. PMID:26867555

  13. [Fe₃O₄-β-Cyclodextrin Polymer Nano Composites Solid-Phase Extraction-UV-Vis Spectrophotometry for Separation Analysis Malachite Green].

    Science.gov (United States)

    Feng, Gang; Ping, Wen-hui; Zhu, Xia-shi

    2016-02-01

    In this paper, carboxymethyl-hydroxypropyl-β-cyclodextrin polymer modified magnetic particles Fe₃O₄ (CM-HP-β-CD- CP-MNPs) were prepared and applied to magnetic solid phase extraction of malachite green combined with UV-Visible spectrom- etry detection. The synthesized magnetic particles were characterized by element analysis, Fourier transform infrared spectra and transmission electron microscopy. Several variables affecting the extraction and desorption of malachite green such as pH, the amount of adsorbent, the type and volume of eluent, extraction and desorption time, and temperature were investigated. Under the optimum conditions, malachite green could be adsorbed by CM-HP-β-CDCP-MNPs (RE% = 92), and elution by C₂H₅OH (EE% = 90). the preconcentration factor of the proposed method was approximately 7.5, the CM-HP-β-CDCP-MNPs could be used repeatedly for 5 times and offered better recovery. The linear range and detection limit (DL) were found to be 0.08~8.00 µg · mL⁻¹ and 5.6 ng · mL⁻¹ respectively. This technique had been successfully applied to the determination of malachite green in real samples. The inclusion interaction of CM-HP--CDCP-MNPs with malachite green was studied through FTIR.

  14. Free radicals in irradiated unstabilized polypropylene, as seen by diffuse reflection absorption-spectrophotometry

    International Nuclear Information System (INIS)

    Zagorski, Z.P.; Rafalski, A.

    1998-01-01

    The introduction of UV-Vis absorption spectrophotometry to the study of radiation chemistry of polymers has opened the possibility to investigate even very opaque samples. The virgin powder polypropylene, as obtained from the industrial production line, shows after irradiation unstable products of radiolysis. Until now they were investigated mainly by EPR method. Optical absorption spectra (by diffuse reflection spectrophotometry) contribute to better identification and study of changes in time, temperature and diffusion of reactive gases. Studying the formation of stable compounds, which do not produce EPR signal, we are able to examine these species on the basis of their electronic spectra. The most important results concern the peroxides in irradiated polypropylene

  15. Determination of dissolved inorganic carbon (DIC) and dissolved organic carbon (DOC) in freshwaters by sequential injection spectrophotometry with on-line UV photo-oxidation

    International Nuclear Information System (INIS)

    Tue-Ngeun, Orawan; Sandford, Richard C.; Jakmunee, Jaroon; Grudpan, Kate; McKelvie, Ian D.; Worsfold, Paul J.

    2005-01-01

    An automated sequential injection (SI) method for the determination of dissolved inorganic carbon (DIC) and dissolved organic carbon (DOC) in freshwaters is presented. For DIC measurement on-line sample acidification (sulphuric acid, pH 2 which subsequently diffused through a PTFE membrane into a basic, cresol red acceptor stream. The CO 2 increased the concentration of the acidic form of the cresol red indicator, with a resultant decrease in absorbance at 570 nm being directly proportional to DIC concentration. DIC + DOC was determined after on-line sample irradiation (15 W low power UV lamp) coupled with acid-peroxydisulfate digestion, with the subsequent detection of CO 2 as described above. DOC was determined by subtraction of DIC from (DIC + DOC). Analytical figures of merit were linear ranges of 0.05-5.0 mg C L -1 for both DIC and DIC + DOC, with typical R.S.D.s of less than 7% (0.05 mg C L -1 -5.3% for DIC and 6.6% for DIC + DOC; 4.0 mg C L -1 -2.6% for DIC and 2.4% for DIC + DOC, n = 3) and an LOD (blank + 3S.D.) of 0.05 mg C L -1 . Sample throughput for the automated system was 8 h -1 for DIC and DOC with low reagent consumption (acid/peroxydisulfate 200 μL per DIC + DOC analysis). A range of model carbon compounds and Tamar River (Plymouth, UK) samples were analysed for DIC and DOC and the results showed good agreement with a high temperature catalytic oxidation (HTCO) reference method (t-test, P = 0.05)

  16. Determination of dissolved inorganic carbon (DIC) and dissolved organic carbon (DOC) in freshwaters by sequential injection spectrophotometry with on-line UV photo-oxidation

    Energy Technology Data Exchange (ETDEWEB)

    Tue-Ngeun, Orawan [Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Sandford, Richard C. [School of Earth, Ocean and Environmental Sciences, University of Plymouth, Drakes Circus, Plymouth PL4 8AA (United Kingdom)]. E-mail: rsandford@plymouth.ac.uk; Jakmunee, Jaroon [Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Grudpan, Kate [Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); McKelvie, Ian D. [Water Studies Centre, School of Chemistry, Monash University, P.O. Box 23, Clayton Campus, Vic. 3800 (Australia); Worsfold, Paul J. [School of Earth, Ocean and Environmental Sciences, University of Plymouth, Drakes Circus, Plymouth PL4 8AA (United Kingdom)

    2005-12-04

    An automated sequential injection (SI) method for the determination of dissolved inorganic carbon (DIC) and dissolved organic carbon (DOC) in freshwaters is presented. For DIC measurement on-line sample acidification (sulphuric acid, pH < 2), converted DIC to CO{sub 2} which subsequently diffused through a PTFE membrane into a basic, cresol red acceptor stream. The CO{sub 2} increased the concentration of the acidic form of the cresol red indicator, with a resultant decrease in absorbance at 570 nm being directly proportional to DIC concentration. DIC + DOC was determined after on-line sample irradiation (15 W low power UV lamp) coupled with acid-peroxydisulfate digestion, with the subsequent detection of CO{sub 2} as described above. DOC was determined by subtraction of DIC from (DIC + DOC). Analytical figures of merit were linear ranges of 0.05-5.0 mg C L{sup -1} for both DIC and DIC + DOC, with typical R.S.D.s of less than 7% (0.05 mg C L{sup -1}-5.3% for DIC and 6.6% for DIC + DOC; 4.0 mg C L{sup -1}-2.6% for DIC and 2.4% for DIC + DOC, n = 3) and an LOD (blank + 3S.D.) of 0.05 mg C L{sup -1}. Sample throughput for the automated system was 8 h{sup -1} for DIC and DOC with low reagent consumption (acid/peroxydisulfate 200 {mu}L per DIC + DOC analysis). A range of model carbon compounds and Tamar River (Plymouth, UK) samples were analysed for DIC and DOC and the results showed good agreement with a high temperature catalytic oxidation (HTCO) reference method (t-test, P = 0.05)

  17. A nanosilver-based spectrophotometry method for sensitive determination of tartrazine in food samples.

    Science.gov (United States)

    Sahraei, R; Farmany, A; Mortazavi, S S

    2013-06-01

    A new method is reported for sensitive determination of tartrazine in the food samples. The method is based on the catalytic effect of silver nanoparticle (AgNPs) on the oxidation reaction of tartrazine by potassium iodate in the acetate buffer medium. The reaction is followed spectrophotometrically by measuring the change in absorbance (ΔA) at 420 nm using a fixed time method (70 s). The reaction variables were optimised in order to achieve the highest sensitivity. The thirty six criterion detection limit was 0.3 ng/mL, and the relative standard deviation for ten replicate measurements of 30 ng/mL of tartrazine was 0.98% (n=10). The method was successfully applied to the determination of tartrazine in lemon, and papaya-flavoured gelatin, candy, and in fruit syrup. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Standard test method for plutonium assay by plutonium (III) diode array spectrophotometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method describes the determination of total plutonium as plutonium(III) in nitrate and chloride solutions. The technique is applicable to solutions of plutonium dioxide powders and pellets (Test Methods C 697), nuclear grade mixed oxides (Test Methods C 698), plutonium metal (Test Methods C 758), and plutonium nitrate solutions (Test Methods C 759). Solid samples are dissolved using the appropriate dissolution techniques described in Practice C 1168. The use of this technique for other plutonium-bearing materials has been reported (1-5), but final determination of applicability must be made by the user. The applicable concentration range for plutonium sample solutions is 10–200 g Pu/L. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropria...

  19. Ratio manipulating spectrophotometry versus chemometry as stability indicating methods for cefquinome sulfate determination.

    Science.gov (United States)

    Yehia, Ali M; Arafa, Reham M; Abbas, Samah S; Amer, Sawsan M

    2016-01-15

    Spectral resolution of cefquinome sulfate (CFQ) in the presence of its degradation products was studied. Three selective, accurate and rapid spectrophotometric methods were performed for the determination of CFQ in the presence of either its hydrolytic, oxidative or photo-degradation products. The proposed ratio difference, derivative ratio and mean centering are ratio manipulating spectrophotometric methods that were satisfactorily applied for selective determination of CFQ within linear range of 5.0-40.0 μg mL(-1). Concentration Residuals Augmented Classical Least Squares was applied and evaluated for the determination of the cited drug in the presence of its all degradation products. Traditional Partial Least Squares regression was also applied and benchmarked against the proposed advanced multivariate calibration. Experimentally designed 25 synthetic mixtures of three factors at five levels were used to calibrate and validate the multivariate models. Advanced chemometrics succeeded in quantitative and qualitative analyses of CFQ along with its hydrolytic, oxidative and photo-degradation products. The proposed methods were applied successfully for different pharmaceutical formulations analyses. These developed methods were simple and cost-effective compared with the manufacturer's RP-HPLC method. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Validation of the ultraviolet spectrophotometry method for the quality control of ciprofloxacin chlorhydrate in Ciprecu tablets

    International Nuclear Information System (INIS)

    Perez Navarro, Maikel; Rodriguez Hernandez, Yaslenis; Suarez Perez, Yania

    2014-01-01

    Quinolones are a group of antimicrobials of high clinical significance. Ciprofloxacin hydrochloride monohydrate is a second-generation antibacterial fluoroquinolone for treatment of several infections and is marketed as eye drops, injections, capsule and tablets. To develop and to validate an ultraviolet spectrophotometric analytical method to be used in the quality control of ciprofloxacin hydrochloride monohydrate in newly manufactured Ciprecu tablets

  1. Polarization control method for UV writing of advanced bragg gratings

    DEFF Research Database (Denmark)

    Deyerl, Hans-Jürgen; Plougmann, Nikolai; Jensen, Jesper Bo Damm

    2002-01-01

    We report the application of the polarization control method for the UV writing of advanced fiber Bragg gratings (FBG). We demonstrate the strength of the new method for different apodization profiles, including the Sinc-profile and two designs for dispersion-free square filters. The method has...

  2. Computation of solution equilibria: A guide to methods in potentiometry, extraction, and spectrophotometry

    International Nuclear Information System (INIS)

    Meloun, M.; Havel, J.; Hogfeldt, E.

    1988-01-01

    Although this book contains a very good review of computation methods applicable to equilibrium systems, most of the book is dedicated to the description and evaluation of computer programs available for doing such calculations. As stated in the preface, the authors (two computniks and a user of graphical and computer methods) have joined forces in order to present the reader with the points of view of both the creator and user of modern computer program tools available for the study of solution equilibria. The successful presentation of such a complicated amalgamation of concepts is greatly aided by the structure of the book, which begins with a brief but thorough discussion of equilibrium concepts in general, followed by an equally brief discussion of experimental methods used to study equilibria with potentiometric, extraction, and spectroscopic methods. These sections would not be sufficient to teach these topics to the beginner but offer an informative presentation of concepts in relation to one another to those already familiar with basic equilibrium concepts. The importance of evaluating and analyzing the suitability of data for further analysis is then presented before an in depth (by a chemist's standards) look at the individual parts that make up a detailed equilibrium analysis program. The next one-third of the book is an examination of specific equilibrium problems and the programs available to study them. These are divided into chapters devoted to potentiometric, extraction, and spectroscopic methods. The format is to discuss a variety of programs, one at a time, including the parts of the program, the types of problems to which it has been applied, and the program's limitations. A number of problems are then presented, which are representative of the type of questions that are normally addressed by research projects in the area

  3. Spectrophotometry of Artemisia tridentata to quantitatively determine subspecies

    Science.gov (United States)

    Richardson, Bryce; Boyd, Alicia; Tobiasson, Tanner; Germino, Matthew

    2018-01-01

    Ecological restoration is predicated on our abilities to discern plant taxa. Taxonomic identification is a first step in ensuring that plants are appropriately adapted to the site. An example of the need to identify taxonomic differences comes from big sagebrush (Artemisia tridentata). This species is composed of three predominant subspecies occupying distinct environmental niches, but overlap and hybridization are common in ecotones. Restoration of A. tridentata largely occurs using wildland collected seed, but there is uncertainty in the identification of subspecies or mix of subspecies from seed collections. Laboratory techniques that can determine subspecies composition would be desirable to ensure that subspecies match the restoration site environment. In this study, we use spectrophotometry to quantify chemical differences in the water-soluble compound, coumarin. Ultraviolet (UV) absorbance of A. tridentata subsp. vaseyana showed distinct differences among A.t. tridentata and wyomingensis. No UV absorbance differences were detected between A.t. tridentata and wyomingensis. Analyses of samples from > 600 plants growing in two common gardens showed that UV absorbance was unaffected by environment. Moreover, plant tissues (leaves and seed chaff) explained only a small amount of the variance. UV fluorescence of water-eluted plant tissue has been used for many years to indicate A.t. vaseyana; however, interpretation has been subjective. Use of spectrophotometry to acquire UV absorbance provides empirical results that can be used in seed testing laboratories using the seed chaff present with the seed to certify A. tridentata subspecies composition. On the basis of our methods, UV absorbance values 3.1 would indicate either A.t. tridentata or wyomingensis. UV absorbance values between 2.7 and 3.1 would indicate a mixture of A.t. vaseyana and the other two subspecies.

  4. Standard test method for color and color difference of whitewares by abriged spectrophotometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2001-01-01

    1.1 This test method describes the instrumental measurement of the reflection properties and color of ceramic glazes and other whitewares by the use of a spectrophotometer or spectrocolorimeter with a hemispherical optical measuring system, such as an integrating sphere. 1.2 The test method is suitable for use with most specimens having an exterior flat surface large enough to cover the spectrophotometer sample port. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. The method of atomic absorption spectrophotometry for determining of cadmium in fruit and vegetable products

    International Nuclear Information System (INIS)

    Brzozowska, B.

    1977-01-01

    The method of atomic absorption with the technique of standard addition was used for determination of cadmium in the following tinned products: green peas, cut bean pods, sorel, stewed black currants, greengage plums, orange juice. The products were dry mineralized. Each mineralizate was divided into three portions, known amounts of cadmium were added to two portions and all portions were supplemented to a defined volume. Determinations were performed using a Pye Unicam SP 90 A spectrophotometer and they served as a base for plotting a curve in the system: absorbance - concentration of added metal. The curve was extrapolated to zero absorbance for reading directly the content of the metal in the product. This content was in the range from 10 to 80 μg/kg at variance coefficient 5-15% and the recovery was 80-130%. (author)

  6. A Spectrophotometric Method for the Determination of Ramipril in ...

    African Journals Online (AJOL)

    HP

    Purpose: To develop a simple and cost effective spectrophotometer method for the determination of. ACE inhibitor ramipril in dosage forms. Methods: UV spectrophotometry was used to develop and validate a simple method .... 2003 software.

  7. Preconcentration of Sn (II) using the methylene blue on the activated carbon and its determination by spectrophotometry method.

    Science.gov (United States)

    Khodadoust, Saeid; Cham Kouri, Narges

    2014-04-05

    A simple and accurate spectrophotometric method for determination of trace amounts of Sn (II) ion in soil sample was developed by using the methylene blue (MB) in the presence of activated carbon (AC) as the adsorbent Solid Phase Extraction (SPE) of Sn (II) and then determined by UV-Vis. The Beer's law is obeyed over the concentration range of 1-80ngmL(-1) of Sn (II) with the detection limits of 0.34ngmL(-1). The influence of type and volume of eluent, concentration of MB, pH, and amount of AC on sensitivity of spectrophotometric method were optimized. The method has been successfully applied for Sn (II) ion determination in soil sample. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Application of UV-Vis spectrophotometric and chemiluminescent methods for the evaluation of the antioxidant action of curcumin

    Czech Academy of Sciences Publication Activity Database

    Stanchev, Stancho; Pencheva, I.; Konstantinov, S.; Obreshkova, D.; Hadjimitova, V.

    2012-01-01

    Roč. 77, č. 8 (2012), s. 1063-1069 ISSN 0352-5139 Institutional research plan: CEZ:AV0Z40550506 Keywords : curcumin * antioxidant * UV-Vis spectrophotometry * DNA complexation * chemiluminescence Subject RIV: CC - Organic Chemistry Impact factor: 0.912, year: 2012

  9. Enhanced Sensitivity to Detection Nanomolar Level of Cu2 + Compared to Spectrophotometry Method by Functionalized Gold Nanoparticles: Design of Sensor Assisted by Exploiting First-order Data with Chemometrics

    Science.gov (United States)

    Rasouli, Zolaikha; Ghavami, Raouf

    2018-02-01

    A simple, sensitive and efficient colorimetric assay platform for the determination of Cu2 + was proposed with the aim of developing sensitive detection based on the aggregation of AuNPs in presence of a histamine H2-receptor antagonist (famotidine, FAM) as recognition site. This study is the first to demonstrate that the molar extinction coefficients of the complexes formed by FAM and Cu2 + are very low (by analyzing the chemometrics methods on the first order data arising from different metal to ligand ratio method), leading to the undesirable sensitivity of FAM-based assays. To resolve the problem of low sensitivity, the colorimetry method based on the Cu2 +-induced aggregation of AuNPs functionalized with FAM was introduced. This procedure is accompanied by a color change from bright red to blue which can be observed with the naked eyes. Detection sensitivity obtained by the developed method increased about 100 fold compared with the spectrophotometry method. This sensor exhibited a good linear relation between the absorbance ratios at 670 to 520 nm (A670/520) and the concentration in the range 2-110 nM with LOD = 0.76 nM. The satisfactory analytical performance of the proposed sensor facilitates the development of simple and affordable UV-Vis chemosensors for environmental applications.

  10. The effect of different propolis harvest methods on its lead contents determined by ET AAS and UV-visS

    Energy Technology Data Exchange (ETDEWEB)

    Sales, A. [Department of Analytical Chemistry, Faculty of Biochemistry, Chemistry and Pharmacy, National University of Tucuman, Ayacucho 471, 4000 Tucuman (Argentina)]. E-mail: amsales@fbqf.unt.edu.ar; Alvarez, A. [National Institute of Agricultural Technology (INTA), Experimental Station Famailla, Ruta 301, Km 32, Famailla, Tucuman (Argentina); Areal, M. Rodriguez [Department of Analytical Chemistry, Faculty of Biochemistry, Chemistry and Pharmacy, National University of Tucuman, Ayacucho 471, 4000 Tucuman (Argentina); Maldonado, L. [National Institute of Agricultural Technology (INTA), Experimental Station Famailla, Ruta 301, Km 32, Famailla, Tucuman (Argentina); Marchisio, P. [Department of Analytical Chemistry, Faculty of Biochemistry, Chemistry and Pharmacy, National University of Tucuman, Ayacucho 471, 4000 Tucuman (Argentina); Rodriguez, M. [Department of Analytical Chemistry, Faculty of Biochemistry, Chemistry and Pharmacy, National University of Tucuman, Ayacucho 471, 4000 Tucuman (Argentina); Bedascarrasbure, E. [National Institute of Agricultural Technology (INTA), Experimental Station Famailla, Ruta 301, Km 32, Famailla, Tucuman (Argentina)

    2006-10-11

    Argentinean propolis is exported to different countries, specially Japan. The market demands propolis quality control according to international standards. The analytical determination of some metals, as lead in food, is very important for their high toxicity even in low concentrations and because of their harmful effects on health. Flavonoids, the main bioactive compounds of propolis, tend to chelate metals as lead, which becomes one of the main polluting agents of propolis. The lead found in propolis may come from the atmosphere or it may be incorporated in the harvest, extraction and processing methods. The aim of this work is to evaluate lead level on Argentinean propolis determined by electrothermal atomic absorption spectrometry (ET AAS) and UV-vis spectrophotometry (UV-visS) methods, as well as the effect of harvest methods on those contents. A randomized test with three different treatments of collection was made to evaluate the effect of harvest methods. These procedures were: separating wedges (traditional), netting plastic meshes and stamping out plastic meshes. By means of the analysis of variance technique for multiple comparisons (ANOVA) it was possible to conclude that there are significant differences between scraped and mesh methods (stamped out and mosquito netting meshes). The results obtained in the present test would allow us to conclude that mesh methods are more advisable than scraped ones in order to obtain innocuous and safe propolis with minor lead contents. A statistical comparison of lead determination by both, ET AAS and UV-visS methods, demonstrated that there is not a significant difference in the results achieved with the two analytical techniques employed.

  11. Ultraviolet Spectrophotometry of VV Cephei

    Directory of Open Access Journals (Sweden)

    Young Woon Kang

    1992-06-01

    Full Text Available The IUE archival spectra of VV Cephei were collected to investigate the eclipse nature in the ultraviolet. The temperature of the B star has been determined, as approximately 30000K, based on the flux distributions during egress. Light curves of VV Cephei were reduced from the spectrophotometry of the IUE archival spectra. Three light curves at the center wavelengths of 3250 Å, 2550 Å and 2850 Å have been analyzed by the modified Wilson and Devinney light curve program. The radii of the B star and M star were deduced to 0.05 and 0.22 of unit separation, respectively. The UV light curves show an evidence that the light was attenuated by the highly opaque atomsphere of the M star.

  12. Spectrophotometry of Symbiotic Stars (Abstract)

    Science.gov (United States)

    Boyd, D.

    2017-12-01

    (Abstract only) Symbiotic stars are fascinating objects - complex binary systems comprising a cool red giant star and a small hot object, often a white dwarf, both embedded in a nebula formed by a wind from the giant star. UV radiation from the hot star ionizes the nebula, producing a range of emission lines. These objects have composite spectra with contributions from both stars plus the nebula and these spectra can change on many timescales. Being moderately bright, they lend themselves well to amateur spectroscopy. This paper describes the symbiotic star phenomenon, shows how spectrophotometry can be used to extract astrophysically useful information about the nature of these systems, and gives results for three symbiotic stars based on the author's observations.

  13. Solid-phase spectrophotometry

    International Nuclear Information System (INIS)

    Brykina, G.D.; Marchenko, D.Yu.; Shpigun, O.A.

    1995-01-01

    Solid-phase spectrophotometry (SPS), which is based on the direct measurement of light absorption of an ion exchanger containing a substance of interest, was reviewed. Since 1976, it has been known that aborbance of an ion exchanger is directly proportional to the concentration of a particular ion in solution. A similar dependence can also be followed for other sorbents, as well as for foams, membranes, films, etc., which do not exhibit ion exchange properties. One can use absorption, diffuse reflection, and luminescence spectra parameters as an analytical signal. Thus, SPS of ion exchangers is among the analytical techniques that combine the sorption concentration and surface determination of the substance of interest. This review summarizes the advancements in SPS over the last six years and demonstrates the prospects for its development. Special attention is paid to experimental methods for measuring solid-phase absorption and to the basic procedures of sample preparation, including new ones. These two facets are of great importance for obtaining precise results and extending the capabilities of SPS

  14. Use of HPLC/UPLC-spectrophotometry for detection of formazan in in vitro Reconstructed human Tissue (RhT)-based test methods employing the MTT-reduction assay to expand their applicability to strongly coloured test chemicals.

    Science.gov (United States)

    Alépée, N; Barroso, J; De Smedt, A; De Wever, B; Hibatallah, J; Klaric, M; Mewes, K R; Millet, M; Pfannenbecker, U; Tailhardat, M; Templier, M; McNamee, P

    2015-06-01

    A number of in vitro test methods using Reconstructed human Tissues (RhT) are regulatory accepted for evaluation of skin corrosion/irritation. In such methods, test chemical corrosion/irritation potential is determined by measuring tissue viability using the photometric MTT-reduction assay. A known limitation of this assay is possible interference of strongly coloured test chemicals with measurement of formazan by absorbance (OD). To address this, Cosmetics Europe evaluated use of HPLC/UPLC-spectrophotometry as an alternative formazan measurement system. Using the approach recommended by the FDA guidance for validation of bio-analytical methods, three independent laboratories established and qualified their HPLC/UPLC-spectrophotometry systems to reproducibly measure formazan from tissue extracts. Up to 26 chemicals were then tested in RhT test systems for eye/skin irritation and skin corrosion. Results support that: (1) HPLC/UPLC-spectrophotometry formazan measurement is highly reproducible; (2) formazan measurement by HPLC/UPLC-spectrophotometry and OD gave almost identical tissue viabilities for test chemicals not exhibiting colour interference nor direct MTT reduction; (3) independent of the test system used, HPLC/UPLC-spectrophotometry can measure formazan for strongly coloured test chemicals when this is not possible by absorbance only. It is therefore recommended that HPLC/UPLC-spectrophotometry to measure formazan be included in the procedures of in vitro RhT-based test methods, irrespective of the test system used and the toxicity endpoint evaluated to extend the applicability of these test methods to strongly coloured chemicals. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. All-Optical Method to Assess Stromal Concentration of Riboflavin in Conventional and Accelerated UV-A Irradiation of the Human Cornea.

    Science.gov (United States)

    Lombardo, Giuseppe; Micali, Norberto Liborio; Villari, Valentina; Serrao, Sebastiano; Lombardo, Marco

    2016-02-01

    We investigated the concentration of riboflavin in human donor corneas during corneal cross-linking using two-photon optical microscopy and spectrophotometry. Eight corneal tissues were de-epithelialized and soaked with 20% dextran-enriched 0.1% riboflavin solution for 30 minutes. After stromal soaking, three tissues were irradiated using a 3 mW/cm2 UV-A device for 30 minutes and three tissues irradiated using a 10 mW/cm2 device for 9 minutes. Two additional tissues were used as positive controls. A Ti:sapphire laser at 810 nm was used to perform two-photon emission fluorescence (TPEF) and second harmonic generation axial scanning measurements in all specimens before and after stromal soaking and after UV-A irradiation. In addition, spectrophotometry was used to collect the absorbance spectra of each tissue at the same time intervals. Analysis of the absorbance spectra and TPEF signals provided measures of the concentration depth profile of riboflavin in corneal stroma. After stromal soaking, the average peak concentration of riboflavin (0.020% ± 0.001%) was found between a stromal depth of 100 and 250 μm; the concentration of riboflavin was almost constant up to 320 ± 53 μm depth, then decreased toward the endothelium, though riboflavin was still enriched in the posterior stroma (0.016%% ± 0.001%). After conventional and accelerated UV-A irradiation, the concentration of riboflavin decreased uniformly 87% ± 2% and 67% ± 3% (P riboflavin in corneal stroma. The method can assist with the assessment of novel riboflavin formulations and different UV-A irradiation protocols.

  16. Novel and validated titrimetric method for determination of selected angiotensin-II-receptor antagonists in pharmaceutical preparations and its comparison with UV spectrophotometric determination

    Directory of Open Access Journals (Sweden)

    Shrikant H. Patil

    2012-12-01

    Full Text Available A novel and simple titrimetric method for determination of commonly used angiotensin-II-receptor antagonists (ARA-IIs is developed and validated. The direct acid base titration of four ARA-IIs, namely eprosartan mesylate, irbesartan, telmisartan and valsartan, was carried out in the mixture of ethanol:water (1:1 as solvent using standardized sodium hydroxide aqueous solution as titrant, either visually using phenolphthalein as an indicator or potentiometrically using combined pH electrode. The method was found to be accurate and precise, having relative standard deviation of less than 2% for all ARA-IIs studied. Also, it was shown that the method could be successfully applied to the assay of commercial pharmaceuticals containing the above-mentioned ARA-IIs. The validity of the method was tested by the recovery studies of standard addition to pharmaceuticals and the results were found to be satisfactory. Results obtained by this method were found to be in good agreement with those obtained by UV spectrophotometric method. For UV spectrophotometric analysis ethanol was used as a solvent and wavelength of 233 nm, 246 nm, 296 nm, and 250 nm was selected for determination of eprosartan mesylate, irbesartan, telmisartan, and valsartan respectively. The proposed titrimetric method is simple, rapid, convenient and sufficiently precise for quality control purposes. Keywords: Angiotensin-II-receptor antagonists, Titrimetric assay, UV spectrophotometry, Validation

  17. Isolation of uv-sensitive variants of human FL cells by a viral suicide method

    International Nuclear Information System (INIS)

    Shiomi, T.; Sato, K.

    1979-01-01

    A new method (viral suicide method) for the isolation of uv-sensitive mutants is described. Colonies of mutagenized human FL cells were infected with uv-irradiated Herpes simplex viruses and surviving ones which seemed to be deficient in host cell reactivation (HCR) were examined for their uv sensitivity. Nineteen of 238 clones examined were sensitive to uv irradiation at the time of the isolation. After recloning, four of these clones have been studied and two (UVS-1 and UVS-2) of them are stable in their uv sensitivity for 4 months in culture. uv sensitivity of UVS-1, UVS-2, and the parental FL cells are as follows: the extrapolation numbers (n) are 2.2, 2.1, and 1.8 and mean lethal doses (DO) are 2.9, 3.7, and 7.8 J/m 2 for UVS-1, UVS-2, and the parental FL cells, respectively. They are no more sensitive than FL cells to x-irradiation. The ability of HCR in UVS-2 cells is apparently lower than that in FL cells, whereas UVS-1 cells are the same as FL cells in the ability

  18. Synthesis of polyaniline nanotubes through UV light catalytic method

    Directory of Open Access Journals (Sweden)

    Chuanyu Sun

    2015-03-01

    Full Text Available In this study, nitrocellulose (NC fiber blanket prepared by electrostatic spinning method has been used as a template, and copper nitrate (Cu(NO32 as an oxidant to synthesise polyaniline nanotubes doped with heteropolyacid (H4SiW12O40, SiW12 using UV light catalytic method. Infrared spectroscopy (IR, X-ray powder diffraction (XRD, scanning electron microscopy (SEM and transmission electron microscopy (TEM technologies were applied to characterize the prepared samples of polyaniline nanotubes. The results show that the external diameter of the tube is about 200 nm, and the internal diameter about 170 nm. We also give a reasonable speculation and explanation about the formation mechanism of the nanotubes.

  19. Development and validation of alternative methods by non-aqueous acid-base titration and derivative ultraviolet spectrophotometry for quantification of sildenafil in raw material and tablets

    Directory of Open Access Journals (Sweden)

    Taízia Dutra Silva

    2017-04-01

    Full Text Available Sildenafil citrate (SILC is a potent phosphodiesterase-5 inhibitor used for erectile dysfunction and pulmonary hypertension. This study shows two simple, fast and alternative analytical methods for SILC determination by non-aqueous titration and by derivative ultraviolet spectrophotometry (DUS in active pharmaceutical ingredient and/or dosage forms. The quantitation method of SILC active pharmaceutical ingredient by non-aqueous acid-base titration was developed using methanol as solvent and 0.1 mol/L of perchloric acid in acetic acid as titrant. The endpoint was potentiometrically detected. The non-aqueous titration method shows satisfactory repeatability and intermediate precision (RSD 0.70-1.09%. The neutralization reaction occurred in the stoichiometric ratio 1:1 in methanol. The determination of SILC active pharmaceutical ingredient or dosage forms by DUS was developed in the linear range from 10 to 40 µg/mL, in 0.01 mol/L HCl, using the first order zero-peak method at λ 256 nm. The DUS method shows selectivity toward tablets excipients, appropriate linearity (R2 0.9996, trueness (recovery range 98.86-99.30%, repeatability and intermediate precision in three concentration levels (RSD 1.17-1.28%; 1.29-1.71%, respectively. Therefore, the methods developed are excellent alternatives to sophisticated instrumental methods and can be easily applied in any pharmaceutical laboratory routine due to simple and fast executions.

  20. Spectrophotometry of RR Telescopii

    International Nuclear Information System (INIS)

    Walker, A.R.

    1977-01-01

    The strongest emission lines in the nova-like variable RR Telescopii were measured during late 1974 using a spectrum scanner. The wavelength range 3350 to 7700 A was scanned with a resolution of 50 A. The results are compared with published spectrophotometry covering the period 1961 to 72, with the conclusion that few changes have taken place in the last 6 yr. No evidence was found that suggested the existence of a cool star, nor was there any indication of night-to-night changes in the emission line intensities. The spectrophotometry of the past 15 yr is consistent with an expanding shell, the emission from this shell being caused by high-energy radiation from an underlying star. (author)

  1. Simple and fast method for iron determination in white and red wines using dispersive liquid-liquid microextraction and ultraviolet-visible spectrophotometry.

    Science.gov (United States)

    Maciel, Juliana V; Soares, Bruno M; Mandlate, Jaime S; Picoloto, Rochele S; Bizzi, Cezar A; Flores, Erico M M; Duarte, Fabio A

    2014-08-20

    This work reports the development of a method for Fe extraction in white and red wines using dispersive liquid-liquid microextraction (DLLME) and determination by ultraviolet-visible spectrophotometry. For optimization of the DLLME method, the following parameters were evaluated: type and volume of dispersive (1300 μL of acetonitrile) and extraction (80 μL of C(2)Cl(4)) solvents, pH (3.0), concentration of ammonium pyrrolidinedithiocarbamate (APDC, 500 μL of 1% m/v APDC solution), NaCl concentration (not added), and extraction time. The calibration curve was performed using the analyte addition method, and the limit of detection and relative standard deviation were 0.2 mg L(-1) and below 7%, respectively. The accuracy was evaluated by comparison of results obtained after Fe determination by graphite furnace atomic absorption spectrometry, with agreement ranging from 94 to 105%. The proposed method was applied for Fe determination in white and red wines with concentrations ranging from 1.3 to 4.7 mg L(-1).

  2. Defects in UV-vis-NIR reflectance spectra as method for forgery detections in writing documents

    Energy Technology Data Exchange (ETDEWEB)

    Somma, F; Aloe, P; Schirripa Spagnolo, G

    2010-11-01

    Documents have taken up a very important place in our society. Frauds committed in connection with documents are not at all uncommon, and, in fact, represent a very large domain of the forensic science called 'questioned documents'. In the field of forensic examination of questioned documents, the legitimacy of an ink entry is often an essential question. A common type of forgery consists in materially altering an existing writing or adding a new writing. These changes can be characterized by means of optical spectroscopy. The aim of this work is to perform the UV-vis-NIR reflectance spectrophotometry to analyze a range of blue and black commercial ballpoint pens, in order to investigate the discriminating abilities of the different inks found on the same document.

  3. MONITORING KADAR NITRIT DAN NITRAT PADA AIR SUMUR DI DAERAH CATUR TUNGGAL YOGYAKARTA DENGAN METODE SPEKTROFOTOMETRI UV-VIS (Monitoring of Nitrite and Nitrate Content in Ground Water of Catur Tunggal Region of Yogyakarta by UV-VIS Spectrophotometry

    Directory of Open Access Journals (Sweden)

    Setiowati Setiowati

    2016-07-01

    Full Text Available ABSTRAK Metode analisis nitrit dan nitrat perlu dikembangkan untuk memonitor kualitas air minum. Kualitas air sumur untuk parameter nitrit dan nitrat dipengaruhi oleh kondisi lingkungan dan kedalaman air sumur.Penelitian ini bertujuan menganalisis nitrit dan nitrat menggunakan asam p-aminobenzoat (PABA pada air sumur di daerah perkotaan Yogyakarta. Analisis nitrit didasarkan pada reaksi antara ion nitrit dengan PABA yang membentuk senyawa azo dengan panjang gelombang maksimum 546 nm. Kedalaman air sumur di daerah Catur Tunggal rata-rata > 10 m. Kadar nitrit dan nitrat pada air sumur adalah 0,05-0,09 dan 8,22-36,58 mg/L. Kadar nitrit dan nitrat tersebut memenuhi baku mutu dan aman untuk dikonsumsi. Konsentrasi nitrit dan nitrat pada air RO adalah 0,05 dan 2,72-59,57 mg/L. Kadar nitrit pada air RO tidak memenuhi baku mutu sedangkan kadar nitrat memenuhi baku mutu kecuali RO 5. ABSTRACT The method for analysis nitrite and nitrate had to developed to monitor the drinking water quality. The well water quality, especially for nitrite and nitrate were influenced by environmental conditions and depth of well. This study aims to analyze nitrite and nitrate using p-aminobenzoic acid (PABA in ground water at urban areas of Yogyakarta. The analysis was based on the reaction between nitrite ions with PABA which form azo compounds with a maximum wavelength of 546 nm. The depth of wells at Catur Tunggal were more than 10 m. Concentration of nitrite and nitrate in well water were 0.05 to 0.09 and 8.22 to 36.58 mg / L. The concentrations met the standard for drinking water quality and was safe for consumption. The concentration of nitrite and nitrate in reverse osmosis (RO water were 0.05 and 2.72 to 59.57 mg / L. The concentration of nitrite did not meet the standard for drinking water quality while the concentration of nitrate met the standard for drinking water quality except RO 5.

  4. Development of a simple, sensitive and inexpensive ion-pairing cloud point extraction approach for the determination of trace inorganic arsenic species in spring water, beverage and rice samples by UV-Vis spectrophotometry.

    Science.gov (United States)

    Gürkan, Ramazan; Kır, Ufuk; Altunay, Nail

    2015-08-01

    The determination of inorganic arsenic species in water, beverages and foods become crucial in recent years, because arsenic species are considered carcinogenic and found at high concentrations in the samples. This communication describes a new cloud-point extraction (CPE) method for the determination of low quantity of arsenic species in the samples, purchased from the local market by UV-Visible Spectrophotometer (UV-Vis). The method is based on selective ternary complex of As(V) with acridine orange (AOH(+)) being a versatile fluorescence cationic dye in presence of tartaric acid and polyethylene glycol tert-octylphenyl ether (Triton X-114) at pH 5.0. Under the optimized conditions, a preconcentration factor of 65 and detection limit (3S blank/m) of 1.14 μg L(-1) was obtained from the calibration curve constructed in the range of 4-450 μg L(-1) with a correlation coefficient of 0.9932 for As(V). The method is validated by the analysis of certified reference materials (CRMs). Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Atomic absorption spectrophotometry in perspective

    International Nuclear Information System (INIS)

    Soffiantini, V.

    1981-01-01

    Atomic absorption spectrophotometry is essentially an analytical technique used for quantitative trace metal analysis in a variety of materials. The speed and specificity of the technique is its greatest advantage over other analytical techniques. What atomic absorption spectrophotometry can and cannot do and its advantages and disadvantages are discussed, a summary of operating instructions are given, as well as a summary of analytical interferences. The applications of atomic absorption spectrophotometry are also shortly discussed

  6. A rapid and accurate method for determining protein content in dairy products based on asynchronous-injection alternating merging zone flow-injection spectrophotometry.

    Science.gov (United States)

    Liang, Qin-Qin; Li, Yong-Sheng

    2013-12-01

    An accurate and rapid method and a system to determine protein content using asynchronous-injection alternating merging zone flow-injection spectrophotometry based on reaction between coomassie brilliant blue G250 (CBBG) and protein was established. Main merit of our approach is that it can avoid interferences of other nitric-compounds in samples, such as melamine and urea. Optimized conditions are as follows: Concentrations of CBBG, polyvinyl alcohol (PVA), NaCl and HCl are 150 mg/l, 30 mg/l, 0.1 mol/l and 1.0% (v/v), respectively; volumes of the sample and reagent are 150 μl and 30 μl, respectively; length of a reaction coil is 200 cm; total flow rate is 2.65 ml/min. The linear range of the method is 0.5-15 mg/l (BSA), its detection limit is 0.05 mg/l, relative standard deviation is less than 1.87% (n=11), and analytical speed is 60 samples per hour. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. A new method of UA_CPE coupled with spectrophotometry for the faster and cost-effective detection of proline in fruit juice, honey, and wine.

    Science.gov (United States)

    Dağdeviren, Semahat; Altunay, Nail; Sayman, Yasin; Gürkan, Ramazan

    2018-07-30

    The study developed a new method for proline detection in honey, wine and fruit juice using ultrasound assisted-cloud point extraction (UA-CPE) and spectrophotometry. Initially, a quaternary complex was built, containing proline, histamine, Cu(II), and fluorescein at pH 5.5. Samples were treated with ethanol-water mixture before extraction and preconcentration, using an ultrasonic bath for 10 min at 40 °C (40 kHz, 300 W). After the optimization of variables affecting extraction efficiency, good linearity was obtained between 15 and 600 µg L -1 with sensitivity enhancement factor of 105. The limits of detection and quantification were 5.7 and 19.0 µg L -1 , respectively. The recovery percentage and relative standard deviations (RSD %) were between 95.3 and 103.3%, and 2.5 and 4.2%, respectively. The accuracy of the method was verified by the analysis of a standard reference material (SRM 2389a). Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Evaluation of phenolic content, total flavonoid and survey of antioxidant activity of leaves of Ficus carica and Pterocarya fraxinifolia trees using spectrophotometry and high performance liquid chromatograph methods

    Directory of Open Access Journals (Sweden)

    Naser Jafari

    2015-09-01

    Full Text Available In this research, to evaluate the antioxidant activity of leaf Pterocarya fraxinifolia (Juglandaceae and Ficus carica (Moraceae extract were carried out by spectrophotometry and high performance liquid chromatography methods. The leaves of P. fraxinifolia and F. carica were collected from Whitney and Shast Kalate (Golestan, Noor (Mazandaran and Asalem (Guilan forests in Iran. Methanolc extract was used in different experiments. The phenolic compounds (gallic acid, coumaric acid and quercetin were also measured by using high performance liquid chromatography (HPLC method.The maximum IC50 for DPPH radical-scavenging activity (595.12±21.4 μg ml-1 were observed in P. fraxinifolia leaves. According to the inhibition time, phenolic compound (gallic acid, coumaric acid and quercetin in F. carica leaves and gallic acid and coumaric acid were detected of Pterocarya leaves methanol extracts. The maximum amount of gallic acid (78.93 and coumaric acid (8.14 in extracts Pterocarya leaves Asalem and the lowest gallic acid (8.56 and coumaric acid (0.89 milligrams per gram was observed in Ficus leaf of Noor forest. Based on the standard chromatogram retention time of gallic acid (2.383, coumaric acid (3.817 and quercetin (7.217 mg/g was reported. This study showed that soil factors, such as potassium, sodium, phosphorus and nitrogen compounds with antioxidant phenolic extracts of the leaves of both plants there is a significant correlation.

  9. UV-C radiation based methods for aqueous metoprolol elimination

    International Nuclear Information System (INIS)

    Rivas, F.J.; Gimeno, O.; Borralho, T.; Carbajo, M.

    2010-01-01

    The endocrine disruptor metoprolol has been oxidised in aqueous solution by means of the systems UV-C, UV-C/H 2 O 2 , UV-C/percarbonate, UV-C/monopersulfate, UV-C/TiO 2 , UV-C/H 2 O 2 /TiO 2 and photo-Fenton. From simple photolysis experiments the quantum yield of metoprolol has been calculated (roughly 5 x 10 -3 mol Einstein -1 at circumneutral pH). Addition of free radicals promoters significantly enhanced the metoprolol depletion rate. Mineralization degree was negligible when no promoter was added, while low values were achieved in the presence of either inorganic peroxides or titanium dioxide. The combination of radiation, hydrogen peroxide and TiO 2 increased the mineralization level up to values in the proximity of 45-50% under the best conditions investigated. The photo-Fenton process was the best system in terms of total oxidation (mineralization degree 70%) when optimum conditions were applied.

  10. UV-C radiation based methods for aqueous metoprolol elimination

    Energy Technology Data Exchange (ETDEWEB)

    Rivas, F.J., E-mail: fjrivas@unex.es [Departamento de Ingenieria Quimica y Quimica Fisica, Universidad de Extremadura, Facultad de Ciencias, Edificio Jose Luis Sotelo, Avenida de Elvas S/N, 06071 Badajoz (Spain); Gimeno, O.; Borralho, T.; Carbajo, M. [Departamento de Ingenieria Quimica y Quimica Fisica, Universidad de Extremadura, Facultad de Ciencias, Edificio Jose Luis Sotelo, Avenida de Elvas S/N, 06071 Badajoz (Spain)

    2010-07-15

    The endocrine disruptor metoprolol has been oxidised in aqueous solution by means of the systems UV-C, UV-C/H{sub 2}O{sub 2}, UV-C/percarbonate, UV-C/monopersulfate, UV-C/TiO{sub 2}, UV-C/H{sub 2}O{sub 2}/TiO{sub 2} and photo-Fenton. From simple photolysis experiments the quantum yield of metoprolol has been calculated (roughly 5 x 10{sup -3} mol Einstein{sup -1} at circumneutral pH). Addition of free radicals promoters significantly enhanced the metoprolol depletion rate. Mineralization degree was negligible when no promoter was added, while low values were achieved in the presence of either inorganic peroxides or titanium dioxide. The combination of radiation, hydrogen peroxide and TiO{sub 2} increased the mineralization level up to values in the proximity of 45-50% under the best conditions investigated. The photo-Fenton process was the best system in terms of total oxidation (mineralization degree 70%) when optimum conditions were applied.

  11. Automation of plutonium spectrophotometry

    International Nuclear Information System (INIS)

    Perez, J.J.; Boisde, G.; Goujon de Beauvivier, M.; Chevalier, G.; Isaac, M.

    1980-01-01

    Instrumentation was designed and constructed for automatic control of plutonium by molecular absorption spectrophotometry, on behalf of the reprocessing facilities, to meet two objectives: on-line measurement, of the valency state of plutonium, on by-pass, with the measured concentration covering the process concentration range up to a few mg.l -1 ; laboratory measurement of plutonium adjusted to valency VI, with operation carried out using a preparative system meeting the required containment specifications. For this two objectives, the photometer, optical cell connections are made by optical fibers resistant to β, γ radiation. Except this characteristic the devices are different according to the quality required for result [fr

  12. Simple and Inexpensive Methods Development for Determination of Venlafaxine Hydrochloride from Its Solid Dosage Forms by Visible Spectrophotometry

    Directory of Open Access Journals (Sweden)

    K. Raghubabu

    2012-01-01

    Full Text Available Two simple, sensitive and cost effective visible spectrophotometric methods (M1 and M2 have been developed for the determination of venlafaxine hydrochloride from bulk and tablet dosage forms. The method M1 is based on the formation of green colored coordination complex by the drug with cobalt thiocyanate which is quantitatively extractable into nitro benzene with an absorption maximum of 626.4 nm. The method M2 involves internal salt formation of aconitic anhydride, dehydration product of citric acid [CIA] with acetic anhydride [Ac2O] to form colored chromogen with an absorption maximum of 561.2 nm. The calibration graph is linear over the concentration range of 10-50 µg/mL and 8-24 µg/mL for method M1 and M2 respectively. The proposed methods are applied to commercial available tablets and the results are statistically compared with those obtained by the reference method and validated by recovery studies. The results are found satisfactory and reproducible. These methods are applied successfully for the estimation of the venlafaxine hydrochloride in the presence of other ingredients that are usually present in dosage forms.

  13. Analysis of nifedipine content in transdermal drug delivery system using non-destructive visible spectrophotometry technique

    International Nuclear Information System (INIS)

    Normaizira Hamidi; Normaizira Hamidi; Normaizira Hamidi; Mohd Nasir Taib; Mohd Nasir Taib; Wui, Wong Tin; Wui, Wong Tin

    2008-01-01

    The applicability of visible spectrophotometry technique as a tool to determine the drug content of polymeric film for use as a transdermal drug delivery system was investigated. Hydroxypropylmethycellulose (HPMC) was selected as the matrix polymer and nifedipine as the model drug. Blank and nifedipine-loaded HPMC films were prepared using the solvent evaporation method. The absorbance spectra of these films under the visible wavelengths between 400 and 800 nm were assessed and compared against the drug content values obtained by means of the conventional destructive UV- spectrophotometry technique. The latter required the use of a solvent system which contained methanol, a harmful organic component in pharmaceutical applications. The results indicated that the absorbance values, attributed to nifedipine, at the wavelengths of 545, 585, 638 and 755nm were significantly correlated to the drug content values obtained using the chemical assay method (Pearson correlation value: r = 0.990 and p < 0.01). The visible spectrophotometry technique is potentially suitable for use to determine the nifedipine content of films owing to its nature of characterization of transdermal drug delivery system which does not require sample destruction during the process of measurement. The samples are recoverable from test and analysis of the entire batch of samples is possible without the need of solvents and chemical reagents. (author)

  14. UV spectroscopy applied to stratospheric chemistry, methods and results

    Energy Technology Data Exchange (ETDEWEB)

    Karlsen, K.

    1996-03-01

    The publication from the Norwegian Institute for Air Research (NILU) deals with an investigation done on stratospheric chemistry by UV spectroscopy. The scientific goals are briefly discussed, and it gives the results from the measuring and analysing techniques used in the investigation. 6 refs., 11 figs.

  15. Simultaneous Detemination of Atorvastatin Calcium and Amlodipine Besylate by Spectrophotometry and Multivariate Calibration Methods in Pharmaceutical Formulations

    Directory of Open Access Journals (Sweden)

    Amir H. M. Sarrafi

    2011-01-01

    Full Text Available Resolution of binary mixture of atorvastatin (ATV and amlodipine (AML with minimum sample pretreatment and without analyte separation has been successfully achieved using a rapid method based on partial least square analysis of UV–spectral data. Multivariate calibration modeling procedures, traditional partial least squares (PLS-2, interval partial least squares (iPLS and synergy partial least squares (siPLS, were applied to select a spectral range that provided the lowest prediction error in comparison to the full-spectrum model. The simultaneous determination of both analytes was possible by PLS processing of sample absorbance between 220-425 nm. The correlation coefficients (R and root mean squared error of cross validation (RMSECV for ATV and AML in synthetic mixture were 0.9991, 0.9958 and 0.4538, 0.2411 in best siPLS models respectively. The optimized method has been used for determination of ATV and AML in amostatin commercial tablets. The proposed method are simple, fast, inexpensive and do not need any separation or preparation methods.

  16. A reliable method of quantification of trace copper in beverages with and without alcohol by spectrophotometry after cloud point extraction

    Directory of Open Access Journals (Sweden)

    Ramazan Gürkan

    2013-01-01

    Full Text Available A new cloud point extraction (CPE method was developed for the separation and preconcentration of copper (II prior to spectrophotometric analysis. For this purpose, 1-(2,4-dimethylphenyl azonapthalen-2-ol (Sudan II was used as a chelating agent and the solution pH was adjusted to 10.0 with borate buffer. Polyethylene glycol tert-octylphenyl ether (Triton X-114 was used as an extracting agent in the presence of sodium dodecylsulphate (SDS. After phase separation, based on the cloud point of the mixture, the surfactant-rich phase was diluted with acetone, and the enriched analyte was spectrophotometrically determined at 537 nm. The variables affecting CPE efficiency were optimized. The calibration curve was linear within the range 0.285-20 µg L-1 with a detection limit of 0.085 µg L-1. The method was successfully applied to the quantification of copper in different beverage samples.

  17. Development and validation of a spectrophotometry method for the determination of histamine in fresh tuna (Thunnus tunna)

    International Nuclear Information System (INIS)

    Chacon-Silva, Fainier; Barquero-Quiros, Miriam

    2002-01-01

    Histamine in foods can promote allergic reactions in sensitive persons. A colorimetric microscale method for histamine determination was developed and validated. Cu 2+ histamine chelation occurs at 9,5 ph. Dichloromethane extraction of the complex as the salt with tetrabromo phenolphthalein ethyl ester, allows photometric quantitation at 515 nm. The validation of micro method was accomplished trough its performance parameters, detection limit, quantitation limit, sensitivity, linearity, precision, recuperation. This methodology was applied to twenty raw tuna samples, collected in San Jose metropolitan area. It was found that 45% of analyzed samples had a histamine content in the range between 100-200 mg/kg. This finding indicates bacterial contamination, 15% of samples analyzed were over 500 mg/kg FDA level of sanitary risk. (Author) [es

  18. Development of a molecular method for testing the effectiveness of UV systems on-site.

    Science.gov (United States)

    Nizri, Limor; Vaizel-Ohayon, Dalit; Ben-Amram, Hila; Sharaby, Yehonatan; Halpern, Malka; Mamane, Hadas

    2017-12-15

    We established a molecular method for quantifying ultraviolet (UV) disinfection efficacy using total bacterial DNA in a water sample. To evaluate UV damage to the DNA, we developed the "DNA damage" factor, which is a novel cultivation-independent approach that reveals UV-exposure efficiency by applying a simple PCR amplification method. The study's goal was to prove the feasibility of this method for demonstrating the efficiency of UV systems in the field using flow-through UV reactors. In laboratory-based experiments using seeded bacteria, the DNA damage tests demonstrated a good correlation between PCR products and UV dose. In the field, natural groundwater sampled before and after being subjected to the full-scale UV reactors was filtered, and the DNA extracted from the filtrate was subjected to PCR amplification for a 900-bp fragment of the 16S rRNA gene with initial DNA concentrations of 0.1 and 1 ng/μL. In both cases, the UV dose predicted and explained a significant proportion of the variance in the log inactivation ratio and DNA damage factor. Log inactivation ratio was very low, as expected in groundwater due to low initial bacterial counts, whereas the DNA damage factor was within the range of values obtained in the laboratory-based experiments. Consequently, the DNA damage factor reflected the true performance of the full-scale UV system during operational water flow by using the indigenous bacterial array present in a water sample. By applying this method, we were able to predict with high confidence, the UV reactor inactivation potential. For method validation, laboratory and field iterations are required to create a practical field calibration curve that can be used to determine the expected efficiency of the full-scale UV system in the field under actual operation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Development and validation of a method for the determination of folic acid in different pharmaceutical formulations using derivative spectrophotometry

    Directory of Open Access Journals (Sweden)

    Marcos Vinícius de Moura Ribeiro

    Full Text Available ABSTRACT Folic acid is a B complex water-soluble vitamin that is essential to humans, and its deficiency can cause problems including congenital malformations in the fetus as well as heart disease. Most countries affected by diseases associated with a lack of folic acid now supplement foods with the vitamin. There is therefore a need for the development of new analytical procedures able to determine folic acid present in different matrices. This work describes the development of zero order and first order derivative spectrophotometric methods for the determination of folic acid in different pharmaceutical formulations, using 0.1 mol L-1 NaOH as solvent. The methods are shown to be simple, selective, and robust. Good linearity was achieved, with correction coefficients ≥0.9996 and limits of detection and quantification ranging from 0.64 to 0.75 and from 1.80 to 2.85 mg L-1, respectively. Recoveries of 98-104% were obtained in accuracy tests, and precision (as RSD was between 0.2 and 4.8%. The methods can be used in routine analyses for quality control purposes, offering an alternative to the procedures already reported in the literature.

  20. A novel and simple fabrication method of embedded SU-8 micro channels by direct UV lithography

    International Nuclear Information System (INIS)

    Fu, C; Hung, C; Huang, H

    2006-01-01

    In this paper, we presents a novel and simple method to fabricate embedded micro channels. The method based on different light absorption properties of the SU-8 thick photoresist under different incident UV wavelengths. The channel structures are defined by the ordinary I-line, while the cover layer is patterned by the deep UV. Because the deep UV is obtained directly on the same aligner with a set of filter mirrors, the embedded channel can be easily produced without other rare facilities. Besides, the relationship between the thickness of the top layer and the exposure dose of the deep UV has been measured by an ingeniously designed experiment. The specific thickness of the top layer of the embedded micro channel can then be secured by the specific deep-UV exposure dose. Further more, many meaningful mechanical structures have been realized by this method, the material property of the top layer are also measured

  1. On image tube spectrophotometry of weak emission lines

    International Nuclear Information System (INIS)

    Duflot, R.

    1979-01-01

    The usual precision of image tube spectrophotometry measures relative to low intensity lines can be improved by the 'method of two lines'. This operating process tested on H II galactic regions leads to a precision of 13%. (Auth.)

  2. Application of experimental design and derivative spectrophotometry methods in optimization and analysis of biosorption of binary mixtures of basic dyes from aqueous solutions.

    Science.gov (United States)

    Asfaram, Arash; Ghaedi, Mehrorang; Ghezelbash, Gholam Reza; Pepe, Francesco

    2017-05-01

    Simultaneous biosorption of malachite green (MG) and crystal violet (CV) on biosorbent Yarrowia lipolytica ISF7 was studied. An appropriate derivative spectrophotometry technique was used to evaluate the concentration of each dye in binary solutions, despite significant interferences in visible light absorbances. The effects of pH, temperature, growth time, initial MG and CV concentration in batch experiments were assessed using Design of Experiment (DOE) according to central composite second order response surface methodology (RSM). The analysis showed that the greatest biosorption efficiency (>99% for both dyes) can be obtained at pH 7.0, T=28°C, 24h mixing and 20mgL -1 initial concentrations for both MG and CV dyes. The quadratic constructed equation ability for fitting experimental data is judged based on criterions like R 2 values, significant p and lack-of-fit value strongly confirm its high adequacy and applicability for prediction of revel behavior of the system under study. The proposed model showed very high correlation coefficients (R 2 =0.9997 for CV and R 2 =0.9989 for MG), while supported by closeness of predicted and experimental value. A kinetic analysis was carried out, showing that for both dyes a pseudo-second order kinetic model adequately describes the available data. The Langmuir isotherm model in single and binary components has better performance for description of dyes biosorption with maximum monolayer biosorption capacity of 59.4 and 62.7mgg -1 in single component and 46.4 and 50.0mgg -1 for CV and MB in binary components, respectively. The surface structure of biosorbents and the possible biosorbents-dyes interactions between were also evaluated by Fourier transform infrared (FT-IR) spectroscopy and scanning electron microscopy (SEM). The values of thermodynamic parameters including ΔG° and ΔH° strongly confirm which method is spontaneous and endothermic. Copyright © 2017. Published by Elsevier Inc.

  3. Determination of Lead and Cadmium in environment materials from the planned area for a nuclear power plant by atomic absorption spectrophotometry method

    International Nuclear Information System (INIS)

    Supriyanto, C; Djokowidodo; Isyuniarto; Heri-Wahyudi; Ashar-Andrianto

    1996-01-01

    The determination of Pb and Cd in environment materials (water, cassava leaves and soil) have been done by atomic absorption spectrophotometry method, The determination of Pb and Cd was done with graphite tube atomizer (GTA) method at optimum condition : wavelength for Pb and Cd 217.0 nm and 228.8 nm; temperature/time ashing 550 o C/37 sec and 350 o C/52 sec; temperature/time atomizing 2000 o C/5.1 sec and 2000 o C/5.2 sec. Modifier for Pb was 3 μL of Mg 1000 μg/ml and Cd was 2 μL of Pd 2000 μg/ml. The content Pb in Spalun river, Hulu Putih river and sea water Lemah Abang was 0.94 ± 0.03; 0.91± 0.02; 4.71 ± 0.26 ng/ml respectively; the Cd content was 1.23 ± 0.11; 0.48 ± 0.01; 0.55 ± 0.01 ng/ml respectively. The Pb dan Cd content in cassava leaves was 163.24 ± 3.72 and 18.45 ± 1.46 ng/g respectively, while the Pb content in soil at the depth variation 0 - 5, 5 - 10, 10 - 20 and 20 - 30 Cm was 2.35 ± 0.15; 2.86 ± 0.16; 1.97 ± 0.11 and 2.19 ± 0.06 μg/g respectively and the Cd content was 43.67 ± 1.52; 37.01 ± 1.01; 31.68 ± 0.17 and 36.97 ± 1.63 ng/g respectively. SRM Citrous leaves from NSB and SRM Soil 7 from the IAEA local used to control the quality of the analyzed method. The Pb, Cd content in SRM was in accordance with the value in the certified legend

  4. Implementation of the method for the determination of lactulose (4-O-β-D-Galactopyranosyl-D-Fructofuranose) and HMF (5-hydroxymethyl-2-furaldehyde) in ultra-pasteurized milk (UHT) ultraviolet-visible spectrophotometry

    International Nuclear Information System (INIS)

    Cardenas Miranda, Jeisson Alberto

    2015-01-01

    Measurement methods of HMF concentrations and lactulose is implemented and evaluated in low-fat milk (2% fat), subjected to ultra pasteurization process in order to establish indicators of nutritional quality. A protocol is developed for the management of equipment and methodology of the analytical method. The determination methods of HMF and lactulose are validated by ultraviolet visible spectrophotometry. The content of HMF and lactulose is determined in different production batches for 4 months of storage at a temperature of 24 Celsius degrees [es

  5. A method for evaluation of UV and biologically effective exposures to plants

    International Nuclear Information System (INIS)

    Paris, A.V.; Southern Queensland Univ., Toowoomba, QLD; Wong, J.C.F.; Galea, V.

    1996-01-01

    This paper presents a method for evaluating the UV and biologically effective exposures to a plant canopy during the irradiation of soybean with supplemental levels of UV radiation in a greenhouse study. The method employs four materials as dosimeters that allow evaluation of the UV spectra. The exposures evaluated at three growth stages were less by factors of 0.44, 0.49 and 0.56 compared to the ambient exposures. At the end of the irradiation period, the ambient biologically effective exposure for generalized plant response was higher by 180% compared to that calculated over the canopy. This is the magnitude of the error in UV studies that provide the ambient exposure as a measure of the UV incident on the plant. Additionally, the difference between the ambient and canopy exposures varied during the growth stages. These results indicate that the dosimetric technique applied to evaluating the UV exposures over a plant canopy is a more accurate representation of the UV exposure incidence on a plant than any obtained by measuring the ambient exposures only. (Author)

  6. Validated UV-Spectrophotometric Methods for Determination of Gemifloxacin Mesylate in Pharmaceutical Tablet Dosage Forms

    Directory of Open Access Journals (Sweden)

    R. Rote Ambadas

    2010-01-01

    Full Text Available Two simple, economic and accurate UV spectrophotometric methods have been developed for determination of gemifloxacin mesylate in pharmaceutical tablet formulation. The first UV-spectrophotometric method depends upon the measurement of absorption at the wavelength 263.8 nm. In second area under curve method the wavelength range for detection was selected from 268.5-258.5 nm. Beer’s law was obeyed in the range of 2 to 12 μgmL-1 for both the methods. The proposed methods was validated statistically and applied successfully to determination of gemifloxacin mesylate in pharmaceutical formulation.

  7. Magnetic resonance cell-tracking studies: spectrophotometry-based method for the quantification of cellular iron content after loading with superparamagnetic iron oxide nanoparticles.

    Science.gov (United States)

    Böhm, Ingrid

    2011-08-01

    The purpose of this article is to present a user-friendly tool for quantifying the iron content of superparamagnetic labeled cells before cell tracking by magnetic resonance imaging (MRI). Iron quantification was evaluated by using Prussian blue staining and spectrophotometry. White blood cells were labeled with superparamagnetic iron oxide (SPIO) nanoparticles. Labeling was confirmed by light microscopy. Subsequently, the cells were embedded in a phantom and scanned on a 3 T magnetic resonance tomography (MRT) whole-body system. Mean peak wavelengths λ(peak) was determined at A(720 nm) (range 719-722 nm). Linearity was proven for the measuring range 0.5 to 10 μg Fe/mL (r  =  .9958; p  =  2.2 × 10(-12)). The limit of detection was 0.01 μg Fe/mL (0.1785 mM), and the limit of quantification was 0.04 μg Fe/mL (0.714 mM). Accuracy was demonstrated by comparison with atomic absorption spectrometry. Precision and robustness were also proven. On T(2)-weighted images, signal intensity varied according to the iron concentration of SPIO-labeled cells. Absorption spectrophotometry is both a highly sensitive and user-friendly technique that is feasible for quantifying the iron content of magnetically labeled cells. The presented data suggest that spectrophotometry is a promising tool for promoting the implementation of magnetic resonance-based cell tracking in routine clinical applications (from bench to bedside).

  8. Magnetic Resonance Cell-Tracking Studies: Spectrophotometry-Based Method for the Quantification of Cellular Iron Content after Loading with Superparamagnetic Iron Oxide Nanoparticles

    Directory of Open Access Journals (Sweden)

    Ingrid Böhm

    2011-07-01

    Full Text Available The purpose of this article is to present a user-friendly tool for quantifying the iron content of superparamagnetic labeled cells before cell tracking by magnetic resonance imaging (MRI. Iron quantification was evaluated by using Prussian blue staining and spectrophotometry. White blood cells were labeled with superparamagnetic iron oxide (SPIO nanoparticles. Labeling was confirmed by light microscopy. Subsequently, the cells were embedded in a phantom and scanned on a 3 T magnetic resonance tomography (MRT whole-body system. Mean peak wavelengths Λpeak was determined at A720nm (range 719–722 nm. Linearity was proven for the measuring range 0.5 to 10 μg Fe/mL (r = .9958; p = 2.2 × 10−12. The limit of detection was 0.01 μg Fe/mL (0.1785 mM, and the limit of quantification was 0.04 μg Fe/mL (0.714 mM. Accuracy was demonstrated by comparison with atomic absorption spectrometry. Precision and robustness were also proven. On T2-weighted images, signal intensity varied according to the iron concentration of SPIO-labeled cells. Absorption spectrophotometry is both a highly sensitive and user-friendly technique that is feasible for quantifying the iron content of magnetically labeled cells. The presented data suggest that spectrophotometry is a promising tool for promoting the implementation of magnetic resonance-based cell tracking in routine clinical applications (from bench to bedside.

  9. Method development and validation of potent pyrimidine derivative by UV-VIS spectrophotometer.

    Science.gov (United States)

    Chaudhary, Anshu; Singh, Anoop; Verma, Prabhakar Kumar

    2014-12-01

    A rapid and sensitive ultraviolet-visible (UV-VIS) spectroscopic method was developed for the estimation of pyrimidine derivative 6-Bromo-3-(6-(2,6-dichlorophenyl)-2-(morpolinomethylamino) pyrimidine4-yl) -2H-chromen-2-one (BT10M) in bulk form. Pyrimidine derivative was monitored at 275 nm with UV detection, and there is no interference of diluents at 275 nm. The method was found to be linear in the range of 50 to 150 μg/ml. The accuracy and precision were determined and validated statistically. The method was validated as a guideline. The results showed that the proposed method is suitable for the accurate, precise, and rapid determination of pyrimidine derivative. Graphical Abstract Method development and validation of potent pyrimidine derivative by UV spectroscopy.

  10. A Study on the Application of UV Sterilization Method in HVAC System

    International Nuclear Information System (INIS)

    Cho, S. W.; Park, J. S.; Seo, I. W.; Lim, K. R.; An, W. S.; Oh, S. H.; Lee, K. W.; Kim, J. G.; Kwon, S. J.

    2005-04-01

    The objective of this report is to study on the application of UV sterilization method on HVAC system in building. One type of commercial UV lamp was utilized during this research. It was 1,050 mm length, 24.5 mm diameter, 65 w lamp output, single ended lamp intended for insertion into al frame from inside. Twenty six lamps were mounted and operated in cross flow. They were allowed to operate for at least 30 minutes prior to beginning each test. The test rig was operated at 2.5 m/s and 20 .deg. C, and the relatively humidity 21.6 %RH. The effect of UV sterilization are investigated that as the general virus about 94 %, the mold microbe about 64 % and the bacillus about 86 %, respectively. Following this report will be used important data for the design and manufacture of the UV

  11. A Study on the Application of UV Sterilization Method in HVAC System

    Energy Technology Data Exchange (ETDEWEB)

    Cho, S. W.; Park, J. S.; Seo, I. W.; Lim, K. R.; An, W. S.; Oh, S. H.; Lee, K. W.; Kim, J. G.; Kwon, S. J

    2005-04-15

    The objective of this report is to study on the application of UV sterilization method on HVAC system in building. One type of commercial UV lamp was utilized during this research. It was 1,050 mm length, 24.5 mm diameter, 65 w lamp output, single ended lamp intended for insertion into al frame from inside. Twenty six lamps were mounted and operated in cross flow. They were allowed to operate for at least 30 minutes prior to beginning each test. The test rig was operated at 2.5 m/s and 20 .deg. C, and the relatively humidity 21.6 %RH. The effect of UV sterilization are investigated that as the general virus about 94 %, the mold microbe about 64 % and the bacillus about 86 %, respectively. Following this report will be used important data for the design and manufacture of the UV.

  12. Analytical application of derivative spectrophotometry

    Directory of Open Access Journals (Sweden)

    VIOLETA M. STEFANOVIC

    2000-07-01

    Full Text Available 1. Introduction 2. Basic characteristics of derivative spectrophotometry 2.1. Increase of spectra resolution 2.2. Elimination of the influence of baseline shift and matrix interferences 2.3. Enhancement of the detectability of minor spectral features 2.4. Precise determination of the positions of absorption maxima 2.5. Signal-to-noise ratio (SNR 2.6. Quantitative analysis 3. Analytical applications 3.1. Inorganic analysis 3.2. Organic and pharmaceutical analysis 3.3. Analysis of food and water 3.4. Application of derivative spectrophotometry for the determination of equilibrium constants

  13. ICH Guidelines-compliant HPLC-UV Method for Pharmaceutical ...

    African Journals Online (AJOL)

    NICOLAAS

    samples; (2) the method devoted to analysis of plasma samples is relying on intensive and costly ... by Saudi Food & Drug Authority Laboratories (Riyadh, Saudi. Arabia). .... The ruggedness of the method was evaluated by altering the .... PDGFRb+ perivascular progenitor cells in tumours regulate pericyte differentiation and ...

  14. A new method for estimating UV fluxes at ground level in cloud-free conditions

    Science.gov (United States)

    Wandji Nyamsi, William; Pitkänen, Mikko R. A.; Aoun, Youva; Blanc, Philippe; Heikkilä, Anu; Lakkala, Kaisa; Bernhard, Germar; Koskela, Tapani; Lindfors, Anders V.; Arola, Antti; Wald, Lucien

    2017-12-01

    A new method has been developed to estimate the global and direct solar irradiance in the UV-A and UV-B at ground level in cloud-free conditions. It is based on a resampling technique applied to the results of the k-distribution method and the correlated-k approximation of Kato et al. (1999) over the UV band. Its inputs are the aerosol properties and total column ozone that are produced by the Copernicus Atmosphere Monitoring Service (CAMS). The estimates from this new method have been compared to instantaneous measurements of global UV irradiances made in cloud-free conditions at five stations at high latitudes in various climates. For the UV-A irradiance, the bias ranges between -0.8 W m-2 (-3 % of the mean of all data) and -0.2 W m-2 (-1 %). The root mean square error (RMSE) ranges from 1.1 W m-2 (6 %) to 1.9 W m-2 (9 %). The coefficient of determination R2 is greater than 0.98. The bias for UV-B is between -0.04 W m-2 (-4 %) and 0.08 W m-2 (+13 %) and the RMSE is 0.1 W m-2 (between 12 and 18 %). R2 ranges between 0.97 and 0.99. This work demonstrates the quality of the proposed method combined with the CAMS products. Improvements, especially in the modeling of the reflectivity of the Earth's surface in the UV region, are necessary prior to its inclusion into an operational tool.

  15. Computer tomography of the brain and spectrophotometry of the CSF in cerebral concussion and contusion

    International Nuclear Information System (INIS)

    Bergvall, U.; Kjellin, K.G.; Levander, B.; Svendsen, P.; Soederstroem, C.E.

    1978-01-01

    Computer tomography (CT) and spectrophotometry of CSF were performed in 30 patients with the clinical diagnosis of cerebral concussion or contusion. The patients with concussion all had normal CT-findings. Spectrophotometry of CSF was sometimes positive for cerebral contusion with normal CT-findings, but the two methods were complementary so that the extent of the lesion was determined by CT and spectrophotometry of CSF indicated the cause. (Auth.)

  16. A Facile Vortex-Assisted Dispersive Liquid-Liquid Microextraction Method for the Determination of Uranyl Ion at Low Levels by Spectrophotometry.

    Science.gov (United States)

    Corazza, Marcela Zanetti; Pires, Igor Matheus Ruiz; Diniz, Kristiany Moreira; Segatelli, Mariana Gava; Tarley, César Ricardo Teixeira

    2015-08-01

    A facile and reliable UV-Vis spectrophotometric method associated with vortex-assisted dispersive liquid-liquid microextraction has been developed and applied to the determination of U(VI) at low levels in water samples. It was based on preconcentration of 24.0 mL sample at pH 8.0 in the presence of 7.4 µmol L(-1) 1-(2-pyridylazo)-2-naphthol, 1.0 mL of methanol as disperser solvent and 1.0 mL of chloroform as extraction solvent. A high preconcentration factor was achieved (396 times), thus providing a wide analytical curve from 6.9 up to 75.9 µg L(-1) (r=0.9982) and limits of detection and quantification of 0.40 and 1.30 µg L(-1), respectively. When necessary, EDTA or KCN can be used to remove interferences of foreign ions. The method was applied to the analysis of real water samples, such as tap, mineral and lake waters with good recovery values.

  17. Certification of caffeine reference material purity by ultraviolet/visible spectrophotometry and high-performance liquid chromatography with diode-array detection as two independent analytical methods.

    Science.gov (United States)

    Shehata, A B; Rizk, M S; Rend, E A

    2016-10-01

    Caffeine reference material certified for purity is produced worldwide, but no research work on the details of the certification process has been published in the literature. In this paper, we report the scientific details of the preparation and certification of pure caffeine reference materials. Caffeine was prepared by extraction from roasted and ground coffee by dichloromethane after heating in deionized water mixed with magnesium oxide. The extract was purified, dried, and bottled in dark glass vials. Stratified random selection was applied to select a number of vials for homogeneity and stability studies, which revealed that the prepared reference material is homogeneous and sufficiently stable. Quantification of caffeine purity % was carried out using a calibrated UV/visible spectrophotometer and a calibrated high-performance liquid chromatography with diode-array detection method. The results obtained from both methods were combined to drive the certified value and its associated uncertainty. The certified value of the reference material purity was found to be 99.86% and its associated uncertainty was ±0.65%, which makes the candidate reference material a very useful calibrant in food and drug chemical analysis. Copyright © 2016. Published by Elsevier B.V.

  18. Certification of caffeine reference material purity by ultraviolet/visible spectrophotometry and high-performance liquid chromatography with diode-array detection as two independent analytical methods

    Directory of Open Access Journals (Sweden)

    A.B. Shehata

    2016-10-01

    Full Text Available Caffeine reference material certified for purity is produced worldwide, but no research work on the details of the certification process has been published in the literature. In this paper, we report the scientific details of the preparation and certification of pure caffeine reference materials. Caffeine was prepared by extraction from roasted and ground coffee by dichloromethane after heating in deionized water mixed with magnesium oxide. The extract was purified, dried, and bottled in dark glass vials. Stratified random selection was applied to select a number of vials for homogeneity and stability studies, which revealed that the prepared reference material is homogeneous and sufficiently stable. Quantification of caffeine purity % was carried out using a calibrated UV/visible spectrophotometer and a calibrated high-performance liquid chromatography with diode-array detection method. The results obtained from both methods were combined to drive the certified value and its associated uncertainty. The certified value of the reference material purity was found to be 99.86% and its associated uncertainty was ±0.65%, which makes the candidate reference material a very useful calibrant in food and drug chemical analysis.

  19. Spectrophotometry of nova Cygni 1975

    International Nuclear Information System (INIS)

    Panek, R.J.

    1977-01-01

    Low-resolution spectrophotometry of nova Cygni 1975 is presented for eight nights in September 1975. Representative spectrum scans from 3600 A to 4500 A (10 A bandpass) and from 6350 A to 6750 A (20 A bandpass) also are shown

  20. A Simple UV Spectrophotometric Method for the Determination of ...

    African Journals Online (AJOL)

    The method was also used in the determination of the content of levofloxacin in two commercial brands of levofloxacin in the Nigerian market. Results: The regression data for the calibration plots exhibited good linear relationship (r = 0.999) over a concentration range of 0.25 – 12.0 ìg/ml and the linear regression equation ...

  1. Diseño y validación de un método espectrofotométrico para el control de calidad del piroxicam jalea 0,5 % Design and validation of a spectrophotometry method used in quality control of a 0,5 % Piroxican jelly

    Directory of Open Access Journals (Sweden)

    Yania Suárez Pérez

    2009-12-01

    Full Text Available La jalea de piroxicam al 0,5 % es un nuevo producto en fase de desarrollo de la Empresa Laboratorio "Roberto Escudero Díaz". En el presente trabajo se diseñó un método por espectrofotometría UV, para lo cual se empleó ácido clorhídrico etanólico como disolvente y 328 nm como longitud de onda de máxima absorción. Se estableció un procedimiento simple y rápido para procesar la muestra previa al análisis. Posteriormente se aplicó la validación de este según exigencias regulatorias actuales. El método resultó suficientemente específico, lineal, preciso y exacto en el rango de 3,125 a 9,375 µg/mL. Se aplicó a la cuantificación del principio activo en 3 lotes de la formulación desarrollada, con resultados satisfactorios sin diferencias estadísticamente significativas según el procesamiento aplicado.The 0.5 % jelly Piroxican is a new product in developing phase from "Roberto Escudero Díaz" Laboratory Enterprise. In present paper a UV spectrophotometry method was designed using ethanol chloride acid as solvent and 328 nm as maximal absorption wave length. A simple and fast procedure was established to processing the sample previous to analysis. Subsequently, we applied the validation of it according current regulatory demands. Method was enough specific, linear, precise and exact at the 3.125 to 9.375 µg/mL. Active principle quantification was applied in three batches of developed formula achieving satisfactory results without statistically significant differences according the applied procedure.

  2. A method for UV-bonding in the fabrication of glass electrophoretic microchips.

    Science.gov (United States)

    Huang, Z; Sanders, J C; Dunsmor, C; Ahmadzadeh, H; Landers, J P

    2001-10-01

    This paper presents an approach for the development of methodologies amenable to simple and inexpensive microchip fabrication, potentially applicable to dissimilar materials bonding and chip integration. The method involves a UV-curable glue that can be used for glass microchip fabrication bonding at room temperature. This involves nothing more than fabrication of glue "guide channels" into the microchip architecture that upon exposure to the appropriate UV light source, bonds the etched plate and cover plate together. The microchip performance was verified by capillary zone electrophoresis (CZE) of small fluorescent molecules with no microchannel surface modification carried out, as well as with a DNA fragment separation following surface modification. The performance of these UV-bonded electrophoretic microchips indicates that this method may provide an alternative to high temperature bonding.

  3. High-Sensitivity Spectrophotometry.

    Science.gov (United States)

    Harris, T. D.

    1982-01-01

    Selected high-sensitivity spectrophotometric methods are examined, and comparisons are made of their relative strengths and weaknesses and the circumstances for which each can best be applied. Methods include long path cells, noise reduction, laser intracavity absorption, thermocouple calorimetry, photoacoustic methods, and thermo-optical methods.…

  4. Comparative determination of phenytoin by spectrophotometry, gas chromatography, liquid chromatography, enzyme immunoassay, and radioimmunoassay

    International Nuclear Information System (INIS)

    Castro, A.; Ibanez, J.; DiCesare, J.L.; Adams, R.F.; Malkus, H.

    1978-01-01

    Sera from patients being treated with phenytoin were analyzed for the drug by spectrophotometry, gas chromatography, radioimmunoasay, enzyme immunoassay, and liquid chromatography. The assay values obtained were intercompared statistically. Enzyme immunoassay and liquid chromatography appear to be attractive alternatives to the more traditional methods of spectrophotometry and gas chromatography. Our radioimmunoassay data correlated poorly with results by the four other methods

  5. The Classification of Ground Roasted Decaffeinated Coffee Using UV-VIS Spectroscopy and SIMCA Method

    Science.gov (United States)

    Yulia, M.; Asnaning, A. R.; Suhandy, D.

    2018-05-01

    In this work, an investigation on the classification between decaffeinated and non- decaffeinated coffee samples using UV-VIS spectroscopy and SIMCA method was investigated. Total 200 samples of ground roasted coffee were used (100 samples for decaffeinated coffee and 100 samples for non-decaffeinated coffee). After extraction and dilution, the spectra of coffee samples solution were acquired using a UV-VIS spectrometer (Genesys™ 10S UV-VIS, Thermo Scientific, USA) in the range of 190-1100 nm. The multivariate analyses of the spectra were performed using principal component analysis (PCA) and soft independent modeling of class analogy (SIMCA). The SIMCA model showed that the classification between decaffeinated and non-decaffeinated coffee samples was detected with 100% sensitivity and specificity.

  6. Derivative spectrophotometry applied to solutions of complex composition

    International Nuclear Information System (INIS)

    Perfil'ev, V.A.

    1986-01-01

    The authors consider not only the basic principles of derivative spectrophotometry but also survey the data on its use in research on the properties of materials, the compositions of compounds, and the structures of complex chemical systems. Recording methods by which derivative spectra can be generated include descriptions of electronic differentiation, computer spectrum differentiation, wavelength modulation, and the two-way derivative method. A section on the advantages of derivative spectrophotometry presents a discussion on features enabling one to determine various substances from their characteristic absorption spectra without performing complicated operations to isolate or separate the components. Other topics include research on the structures of substances and metal-ion complexing in solutions, derivative spectrophotometry in gas analysis, gas determination, and determining organic and compounds

  7. Ion-exchanger ultraviolet spectrophotometry for uranium(VI)

    International Nuclear Information System (INIS)

    Waki, H.; Korkisch, J.

    1983-01-01

    A sensitive method based on solid-phase spectrophotometry has been developed for the microdetermination of uranium(VI) in water samples. Uranium is sorbed on the anion-exchanger QAE-Sephadex from thiocyanate solution and the absorbance of the exchanger is measured at 300 nm. This method is about 30 times more sensitive than solution spectrophotometry. Absorption spectra of various metals in the anion-exchanger phase are presented and their interferences discussed. A procedure for the cation-exchange separation of uranium from accompanying elements before spectral measurement of uranium is proposed. (author)

  8. A Spectrophotometric Method for the Determination of Ramipril in ...

    African Journals Online (AJOL)

    A Spectrophotometric Method for the Determination of Ramipril in Solid Dosage Forms. ... Tropical Journal of Pharmaceutical Research ... Methods: UV spectrophotometry was used to develop and validate a simple method for the assay of ramipril in solid dosage form at λmax of 210 nm, as per International Conference on ...

  9. Multi-filter spectrophotometry simulations

    Science.gov (United States)

    Callaghan, Kim A. S.; Gibson, Brad K.; Hickson, Paul

    1993-01-01

    To complement both the multi-filter observations of quasar environments described in these proceedings, as well as the proposed UBC 2.7 m Liquid Mirror Telescope (LMT) redshift survey, we have initiated a program of simulated multi-filter spectrophotometry. The goal of this work, still very much in progress, is a better quantitative assessment of the multiband technique as a viable mechanism for obtaining useful redshift and morphological class information from large scale multi-filter surveys.

  10. A Research on Determination of Lecithin in Eggs by Applying Microwave Digestion Techniques and Spectrophotometry

    International Nuclear Information System (INIS)

    Wu, M.; Ge, Q.L.; Gao, Y. Sh.; Chen, K. W.

    2012-01-01

    A method to quick detect concentration of lecithin in eggs, namely microwave digestion spectrophotometry, was established in this research. The homogenate of eggs was treated with absolute ethanol to eliminate phosphate protein in eggs which could possibly affect concentration of lecithin examined. A sample then received a new way of pre-treatment, called microwave digestion, before UV-Vis spectrometry was applied to examine the concentration of phosphate at 400 nm. The linear equation was A = 0.08628X (μg), the corresponding coefficient of correlation was 0.9998, the detection limit of phosphorous was 0.2μg (n=11). The content of lecithin in eggs was then obtained. According to the result, the recovery of 90% was secured; therefore the conclusion of high degree of accuracy was reached.

  11. Impurities determination of uranium metal flame spectrophotometry and atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Rukihati.

    1978-01-01

    The atomic absorption flame spectrophotometry has been applied to the determination of chromium, copper, iron, lead, manganese and nickel in the metal of uranium. The first step to be done is to dissolve the uranium sample in nitric acid and then the uranium is extracted by a tributylphosphate-carbon tetrachloride solution. The aqueous phase which contains the chromium, copper, iron, lead, manganese and nickel is aspirated into an airacetylene flame. The results of this method are compared with the results of emission spectrographic method. It is found that this technique is competative to other methods in the sense that it is quite fast and accurate. (author)

  12. Isolation of UV-sensitive mutants of mouse L5178Y cells by a cell suspension spotting method

    International Nuclear Information System (INIS)

    Shiomi, T.; Hieda-Shiomi, N.; Sato, K.

    1982-01-01

    We have isolated 56 UV-sensitive mutant clones from a mouse L51 T/t line of L5178Y cells by a cell suspension spotting method. Five mutants have also been isolated from L51 T/t and L5178Y cells by the method reported by Thompson and coworkers. We divided the mutants into two groups, highly sensitive and moderately sensitive mutants, according to their sensitivity to UV irradiation. Fifty-eight mutants were highly sensitive and three were moderately sensitive to UV. The reconstruction experiments indicate that more than 90% of highly sensitive mutants were recovered by the cell suspension spotting method. Frequencies of recovered mutants highly sensitive to UV increased with increasing dose of mutagens. Recovered mutant frequency reached 10(-2) after treatment with 1.5 micrograms/ml of N-methyl-N'-nitro-N-nitrosoguanidine (MNNG) (survival 0.2%). Eight UV-sensitive mutants were divided into four complementation groups. These mutants were 2-6 times more sensitive to UV than parental L51 T/t cells in terms of D37 (dose required to reduce survival to 37%). Four representative UV-sensitive mutants which are classified into different complementation groups were examined for their sensitivity to killing by UV, 4-nitroquinoline-1-oxide (4NQO), mitomycin C (MMC), X-rays, and MNNG. All four classes of mutants were found to be cross-sensitive to UV, 4NQO, and MMC, but not sensitive to X-rays and MNNG

  13. Indonesian palm civet coffee discrimination using UV-visible spectroscopy and several chemometrics methods

    International Nuclear Information System (INIS)

    Yulia, M; Suhandy, D

    2017-01-01

    Indonesian palm civet coffee or kopi luwak (Indonesian words for coffee and palm civet) is well known as the world’s priciest and rarest coffee. To protect the authenticity of luwak coffee and protect consumer from luwak coffee adulteration, it is very important to develop a simple and inexpensive method to discriminate between civet and non-civet coffee. The discrimination between civet and non-civet coffee in ground roasted (powder) samples is very challenging since it is very difficult to distinguish between the two by using conventional method. In this research, the use of UV-Visible spectra combined with two chemometric methods, SIMCA and PLS-DA, was evaluated to discriminate civet and non-civet ground coffee samples. The spectral data of civet and non-civet coffee were acquired using UV-Vis spectrometer (Genesys™ 10S UV-Vis, Thermo Scientific, USA). The result shows that using both supervised discrimination methods: SIMCA and PLS-DA, all samples were correctly classified into their corresponding classes with 100% rate for accuracy, sensitivity and specificity, respectively. (paper)

  14. UV Spectrophotometric Method for theEstimation of Itopride Hydrochloride in Pharmaceutical Formulation

    OpenAIRE

    K. R. Gupta; R. R. Joshi; R. B. Chawla; S. G. Wadodkar

    2010-01-01

    Three simple, precise and economical UV methods have been developed for the estimation of itopride hydrochloride in pharmaceutical formulations. Itopride hydrochloride in distilled water shows the maximum absorbance at 258.0 nm (Method A) and in first order derivative spectra of the same shows sharp peak at 247.0 nm, when n = 1 (Method B). Method C utilises area under curve (AUC) in the wavelength range from 262.0-254.0 nm for analysis of itopride hydrochloride. The drug was found to obey Bee...

  15. Development and Validation of Analytical Method for Losartan ...

    African Journals Online (AJOL)

    Development and Validation of Analytical Method for Losartan-Copper Complex Using UV-Vis Spectrophotometry. ... Tropical Journal of Pharmaceutical Research ... Purpose: To develop a new spectrophotometric method for the analysis of losartan potassium in pharmaceutical formulations by making its complex with ...

  16. The determination of copper in biological materials by flame spectrophotometry

    Science.gov (United States)

    Newman, G. E.; Ryan, M.

    1962-01-01

    A method for the determination of the copper content of biological materials by flame spectrophotometry is described. The effects of interference by ions such as sodium and phosphate were eliminated by isolating copper as the dithizonate in CCl4. Results obtained for the urinary excretion of copper by a patient with Wilson's disease before and after treatment with penicillamine are reported. PMID:14479334

  17. Zirconium determination in rocks by solid-phase spectrophotometry

    International Nuclear Information System (INIS)

    Brykina, G.D.; Lebedeva, G.G.; Agapova, G.F.; AN SSSR, Moscow

    1990-01-01

    A method was developed for determination of zirconium in rocks by solid-phase spectrophotometry using AV-17x8-Cl anion exchanger modified with xylenol orange. Relative standard deviation at the level of (2-4.9)x10 -3 % ZrO 2 was about 0.245

  18. Determinação de proteínas totais via espectrofometria: vantagens e desvantagens dos métodos existentes Determination of total protein by spectrophotometry: advantages and disadvantages of proposed methods

    Directory of Open Access Journals (Sweden)

    Dimas A. M. Zaia

    1998-11-01

    Full Text Available Spectrophotometric determination of total protein is used in several areas such as clinical analysis, food science and technology, biochemistry, protein chemistry, physiology. Five spectrophotometric methods are mostly used: biuret, Lowry, Bradford, Smith and UV absorption. In this review a general overview of these methods is presented (interferences, applications; other methodologies are also discussed.

  19. Development and Validation of a Stability-Indicating LC-UV Method ...

    African Journals Online (AJOL)

    Development and Validation of a Stability-Indicating LC-UV Method for Simultaneous Determination of Ketotifen and Cetirizine in Pharmaceutical Dosage Forms. ... 5 μm) using an isocratic mobile phase that consisted of acetonitrile and 10 mM disodium hydrogen phosphate buffer (pH 6.5) in a ratio of 45:55 % v/v at a flow ...

  20. Capillary electrophoresis method with UV-detection for analysis of free amino acids concentrations in food.

    Science.gov (United States)

    Omar, Mei Musa Ali; Elbashir, Abdalla Ahmed; Schmitz, Oliver J

    2017-01-01

    Simple and inexpensive capillary electrophoresis with UV-detection method (CE-UV) was optimized and validated for determination of six amino acids namely (alanine, asparagine, glutamine, proline, serine and valine) for Sudanese food. Amino acids in the samples were derivatized with 4-chloro-7-nitro-2,1,3-benzoxadiazole (NBD-Cl) prior to CE-UV analysis. Labeling reaction conditions (100mM borate buffer at pH 8.5, labeling reaction time 60min, temperature 70°C and NBD-Cl concentration 40mM) were systematically investigated. The optimal conditions for the separation were 100mM borate buffer at pH 9.7 and detected at 475nm. The method was validated in terms of linearity, limit of detection (LOD), limit of quantification (LOQ), precision (repeatability) (RSD%) and accuracy (recovery). Good linearity was achieved for all amino acids (r(2)>0.9981) in the concentration range of 2.5-40mg/L. The LODs in the range of 0.32-0.56mg/L were obtained. Recoveries of amino acids ranging from 85% to 108%, (n=3) were obtained. The validated method was successfully applied for the determination of amino acids for Sudanese food samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Method of reinfusion of UV-irradiated autoblood in the treatment of peptic ulcer

    International Nuclear Information System (INIS)

    Murashko, V.V.; Sklyarova, M.A.; Shakhidul, Kh.; Gilis, R.Ya.; Karandashov, V.I.

    1989-01-01

    Efficiency of the reinfusion method for autoblood irradiated by UV-rays during the treatment of 40 patients with peptic ulcer of duodenum and 8 patients with peptic ulcer of stomach is studied. It isestablished that the method above promotes the fast improvement of state of health in patients, the normalization of sleep, appetite, the disappearance of asthenias, aches and the reduction of time of ulcer cicatrization up to 14±4 days. It is supposed that high efficiency of the method is caused by the improvement of microcirculation and trophicity of mucous membrane of stomach and duodenum

  2. UV Spectrophotometric Method for Determination of Cinitapride in Pure and its Solid Dosage Form

    Directory of Open Access Journals (Sweden)

    B. Thangabalan

    2009-01-01

    Full Text Available A new, rapid, precise, accurate and sensitive analytical method was developed for the UV spectrophotometric assay of cinitapride (CTP. The drug obeyed the Beer's law and showed good correlation. It showed absorption maxima at 260 nm in methanol. The linearity was observed between 5-40 µg mL-1. The results of analysis were validated by recovery studies. The recovery was more than 99%. The proposed method is the only method available for spectrophotometric determination of the drug. It is simple, precise, sensitive and reproducible and can be used for the routine quality control testing of the marketed formulations.

  3. Determination of piroxicam in pharmaceutical preparations by ultraviolet direct spectrophotometry, ultraviolet difference spectrophotometry and high performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Hackmann, E.R.M.; Santos Gianotto, E.A. dos; Miritello Santoro, M.I.R. (Universidade de Sao Paulo (Brazil))

    1993-02-01

    Piroxicam in pharmaceutical preparations (capsules (C), tablets (T), oral drops (OD), suppositories (S) and simulated sample (SS)) was determined by UV direct spectrophotometry (UVS) at 333 nm, by UV difference spectrophotometry (UVDS) at 327 nm, and in C and T, by high performance liquid chromatography (HPLC). For UVS, Beer's law was obeyed in the range 3.0-8.5 [mu]g/mL. The coefficient of correlation (CC), absolute precision (AP) and relative precision (RP) were 0.9999, 0.02 and 0.33%, respectively. The coefficient of variation (CV) for C, T, OD, S and SS were 0.48%, 0.35%, 0.48% and 0.19%, respectively. The recovery average (RA) was 100.22%. For UVDS, Beer's law was obeyed in the range 5.0-15.0 [mu]g/mL. The CC, AP and RP were respectively 0.9999, 0.05 and 0.47%. The CV for C, T, OD, S and SS were 0.64%, 0.84%, 0.62%, 0.54% and 0.15%, respectively. The RA was 99.02%. In HPLC determination, a LiChrospher[reg sign] 100 RP-18 (5 [mu]m) in LiChroCART[reg sign] 125-4 column at ambient temperature with a mobile phase consisting of methanol: (buffer solution citric acid-dibasic sodium phosphate pH 3.0) (55:45) and UV detection at 254 nm enabled the determination of piroxicam in C and T. The response peak area versus concentration presented linearity in the range 10.0-100.0 [mu]g/mL. The CC, AP and RP were 0.9997, 0.45 and 0.90%, respectively. The CV was 0.51%-0.82% and the RA, 97.13%. 14 refs., 1 fig., 5 tabs.

  4. Solid-Phase Extraction of Trace Amounts of Uranium(VI in Environmental Water Samples Using an Extractant-Impregnated Resin Followed by Detection with UV-Vis Spectrophotometry

    Directory of Open Access Journals (Sweden)

    Ahmad Hosseini-Bandegharaei

    2013-01-01

    Full Text Available A stable extractant-impregnated resin (EIR containing Chrome Azurol B was prepared using Amberlite XAD-2010 as a porous polymeric support. The new EIR was employed for trace separation and preconcentration of U(VI ion followed by spectrophotometric determination with the arsenazo III procedure. CAB/XAD-2010 exhibited excellent selectivity for U(VI ion over coexisting ions. Experimental parameters including pH, contact time, shaking speed, and ionic strength were investigated by batch extraction methods. Maximum sorption of U(VI ions occurred at pH 4.3–6.9. The capacity of EIR was found to be 0.632 mmol·g−1. Equilibrium was reached in 25 min and the loading half-time, t1/2, was less than 6 min. The equilibrium adsorption isotherm of U(VI was fitted with the Langmuir adsorption model. In addition, a column packed with CAB/XAD-2010 was used for column-mode separation and preconcentration of U(VI ion. For the optimization of the dynamic procedure, effects of sample volume, sample and eluent flow rate, eluent concentration, and its volume were investigated. The preconcentration factors for U(VI were found out to be 160. But, for convenience, a preconcentration factor of 150 was utilized for the column-mode preconcentration. The dynamic procedure gave a detection limit of 5.0×10-10 mol·L−1 (0.12 μg·L−1 for U(VI ion. The proposed dynamic method showed good performance in analyzing environmental water samples.

  5. Facile method for liquid-exfoliated graphene size prediction by UV-visible spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ismail, Zulhelmi, E-mail: helmie83@hotmail.com [Faculty of Manufacturing Engineering, Universiti Malaysia Pahang, 26600 Pekan, Pahang (Malaysia); Yusoh, Kamal, E-mail: kamal@ump.edu.my [Faculty of Chemical Engineering and Natural Resources, Universiti Malaysia Pahang, Lebuhraya Tun Razak, 26300 Kuantan, Pahang (Malaysia)

    2016-07-19

    In this work, an application of UV spectroscopy for facile prediction of liquid –exfoliated graphene size is discussed. Dynamic light scattering method was used to estimate the graphene flake size ( whilst UV spectroscopy measurement was carried out for extinction coefficient value (ε) determination. It was found that the value of (ε) decreased gradually as the graphene size was further reduced after intense sonication time (7h). This observation showed the influence of sonication time on electronic structure of graphene. A mathematical equation was derived from log-log graph for correlation between () and (ε) value. Both values can be expressed in a single equation as ( = (3.4 × 10{sup −2}) ε{sup 1.2}).

  6. A Simple and Efficient Method to Improve Mechanical Properties of Collagen Scaffolds by UV Irradiation

    Directory of Open Access Journals (Sweden)

    F. Khayyatan

    2010-12-01

    Full Text Available Collagen is the major protein component of cartilage, bone, skin and connective tissue and constitutes the major part of the extracellular matrix. Collagen type I has complex structural hierarchy, which consists of treepolypeptide α-chains wound together in a rod-like helical structure. Collagen is an important biomaterial, finding many applications in the field of tissue engineering. It has been processed into various shapes, such as, gel, film, sponge and fiber. It is commonly used as the scaffolding material for tissue engineering due to its many superior properties including low antigenicity and high growth promotion. Unfortunately, poor mechanical properties and rapid degradation rates of collagen scaffolds can cause instability and difficulty in handling. By crosslinking, the structural stability of the collagen and its rate of resorption can be adapted with respect to its demanding requirements. The strength, resorption rate, and biocompatibility of collagenous biomaterials are profoundly influenced by the method and extent of crosslinking. In thisstudy, the effect of UV irradiation on collagen scaffolds has been carried out.Collagen scaffolds were fabricated using freeze drying method with freezing temperature of -80oC, then exposed to UV irradiation. Mean pore size of the scaffolds was obtained as 98.52±14.51 μm using scanning electron microscopy. Collagen scaffolds exposed to UV Irradiation (254 nm for 15 min showed the highest tensile strain (17.37±0.98 %, modulus (1.67±0.15 MPa and maximum load (24.47±2.38 cN values. As partial loss of the native collagen structure may influence attachment, migration, and proliferation of cells on collagen scaffolds, we detected no intact α-chains after SDS-Page chromatography. We demonstrate that UV irradiation is a rapid and easily controlled means of increasing the mechanical strength of collagen scaffolds without any molecular fracture.

  7. Flare activity on UV Ceti: visible and IUE observations

    International Nuclear Information System (INIS)

    Phillips, K.J.H.; Bromage, G.E.; Dufton, P.L.; Keenan, F.P.; Kingston, A.E.

    1988-01-01

    Simultaneous far-ultraviolet (IUE) spectroscopy and optical photometry and spectrophotometry of a flare on UV Ceti are reported. The flare reached ΔU=2 mag but showed only modest enhancements in the IUE spectra. The optical spectrophotometry indicated broadened Balmer line profiles during the flare, with Hβ and Hγ clearly showing red wings (∼ 100 km s -1 ). The results are compared with other IUE and optical observations of UV Ceti, and their solar analogues. (author)

  8. Flare activity on UV CETI: visible and IUE observations

    International Nuclear Information System (INIS)

    Phillips, K.J.H.; Bromage, G.E.; Dufton, P.L.; Keenan, F.P.; Kingston, A.E.

    1988-06-01

    Simultaneous far-ultraviolet (IUE) spectroscopy and optical photometry and spectrophotometry of a flare on UV Ceti are reported. The flare reached ΔU = 2sup(m) but showed only modest enhancements in the IUE spectra. The optical spectrophotometry indicated broadened Balmer line profiles during the flare, with Hβ and Hγ clearly showing red wings. The results are compared with other IUE and optical observations of UV Ceti, and their solar analogues. (author)

  9. Simultaneous Chloramphenicol and Florfenicol Determination by A Validated DLLME-HPLC-UV Method in Pasteurized Milk

    OpenAIRE

    Karami-Osboo, Rouhollah; Miri, Ramin; Javidnia, Katayoun; Kobarfard, Farzad

    2016-01-01

    The antibiotic residues in milk are a well-known serious problem and pose several health hazards to consumers. We have described a simple, rapid, and inexpensive DLLME-HPLC/UV technique for the extraction of chloramphenicol and florfenicol residues in milk samples. Under the optimum conditions, linearity of the method was observed over the range 0.02-0.85 ?g/L with correlation coefficients > 0.999. The proposed method has been found to have a good limit of detection (signal to noise ratio = 3...

  10. UV and humidity sensing properties of ZnO nanorods prepared by the arc discharge method

    International Nuclear Information System (INIS)

    Fang, F; Futter, J; Markwitz, A; Kennedy, J

    2009-01-01

    The UV and humidity sensing properties of ZnO nanorods prepared by arc discharge have been studied. Scanning electron microscopy and photoluminescence spectroscopy were carried out to analyze the morphology and optical properties of the as-synthesized ZnO nanorods. Proton induced x-ray emission was used to probe the impurities in the ZnO nanorods. A large quantity of high purity ZnO nanorod structures were obtained with lengths of 0.5-1 μm. The diameters of the as-synthesized ZnO nanorods were found to be between 40 and 400 nm. The nanorods interlace with each other, forming 3D networks which make them suitable for sensing application. The addition of a polymeric film-forming agent (BASF LUVISKOL VA 64) improved the conductivity, as it facilitates the construction of conducting networks. Ultrasonication helped to separate the ZnO nanorods and disperse them evenly through the polymeric agent. Improved photoconductivity was measured for a ZnO nanorod sensor annealed in air at 200 deg. C for 30 min. The ZnO nanorod sensors showed a UV-sensitive photoconduction, where the photocurrent increased by nearly four orders of magnitude from 2.7 x 10 -10 to 1.0 x 10 -6 A at 18 V under 340 nm UV illumination. High humidity sensitivity and good stability were also measured. The resistance of the ZnO nanorod sensor decreased almost linearly with increasing relative humidity (RH). The resistance of the ZnO nanorods changed by approximately five orders of magnitude from 4.35 x 10 11 Ω in dry air (7% RH) to about 4.95 x 10 6 Ω in 95% RH air. It is experimentally demonstrated that ZnO nanorods obtained by the arc discharge method show excellent performance and promise for applications in both UV and humidity sensors.

  11. Validation of HPLC and UV spectrophotometric methods for the determination of meropenem in pharmaceutical dosage form.

    Science.gov (United States)

    Mendez, Andreas S L; Steppe, Martin; Schapoval, Elfrides E S

    2003-12-04

    A high-performance liquid chromatographic method and a UV spectrophotometric method for the quantitative determination of meropenem, a highly active carbapenem antibiotic, in powder for injection were developed in present work. The parameters linearity, precision, accuracy, specificity, robustness, limit of detection and limit of quantitation were studied according to International Conference on Harmonization guidelines. Chromatography was carried out by reversed-phase technique on an RP-18 column with a mobile phase composed of 30 mM monobasic phosphate buffer and acetonitrile (90:10; v/v), adjusted to pH 3.0 with orthophosphoric acid. The UV spectrophotometric method was performed at 298 nm. The samples were prepared in water and the stability of meropenem in aqueous solution at 4 and 25 degrees C was studied. The results were satisfactory with good stability after 24 h at 4 degrees C. Statistical analysis by Student's t-test showed no significant difference between the results obtained by the two methods. The proposed methods are highly sensitive, precise and accurate and can be used for the reliable quantitation of meropenem in pharmaceutical dosage form.

  12. Chemical dosimetry by UV spectrophotometry of aqueous ascorbic acid solutions

    International Nuclear Information System (INIS)

    Alian, A.; El-Assay, N.B.; Abdel-Rehim, F.; Amin, N.E.; McLaughlin, W.L.; Roushdy, H.

    1984-01-01

    The decrease in the ultraviolet absorption of aqueous solutions of ascorbic acid brought about by large doses of gamma radiation has been investigated as a means of developing a new chemical dosimeter. Because of spontaneous ring opening under various conditions after dissolution in water, some additives were examined as possible stabilizers against such denaturing of aqueous ascorbic acid. At an ascorbic acid concentration of 10 -4 M, either 1 to 2% glycine or 0.2 M NaCl was found to be a good stabilizer. A mechanism of radiation chemistry has been proposed based on hydroxyl radical and hydroxyl adduct intermediates, leading to dehydroascorbic acid through the ascorbate complex. The optimum dosimeter solution covers an absorbed dose range approx. 50 to 350 Gy, when measured at 264 nm wavelength. The G-values for dehydroascorbic acid production were determined to be 2.94 +- 0.33 and 2.43 +- 0.11 (100 eV) -1 , with glycine and NaCl used respectively as stabilizers. (author)

  13. UV Spectrophotometric Method for theEstimation of Itopride Hydrochloride in Pharmaceutical Formulation

    Directory of Open Access Journals (Sweden)

    K. R. Gupta

    2010-01-01

    Full Text Available Three simple, precise and economical UV methods have been developed for the estimation of itopride hydrochloride in pharmaceutical formulations. Itopride hydrochloride in distilled water shows the maximum absorbance at 258.0 nm (Method A and in first order derivative spectra of the same shows sharp peak at 247.0 nm, when n = 1 (Method B. Method C utilises area under curve (AUC in the wavelength range from 262.0-254.0 nm for analysis of itopride hydrochloride. The drug was found to obey Beer-Lambert’s law in the concentration range of 5-50 μg/mL for all three proposed methods. Results of the analysis were validated statistically and recovery studies were found to be satisfactory.

  14. Method validation using weighted linear regression models for quantification of UV filters in water samples.

    Science.gov (United States)

    da Silva, Claudia Pereira; Emídio, Elissandro Soares; de Marchi, Mary Rosa Rodrigues

    2015-01-01

    This paper describes the validation of a method consisting of solid-phase extraction followed by gas chromatography-tandem mass spectrometry for the analysis of the ultraviolet (UV) filters benzophenone-3, ethylhexyl salicylate, ethylhexyl methoxycinnamate and octocrylene. The method validation criteria included evaluation of selectivity, analytical curve, trueness, precision, limits of detection and limits of quantification. The non-weighted linear regression model has traditionally been used for calibration, but it is not necessarily the optimal model in all cases. Because the assumption of homoscedasticity was not met for the analytical data in this work, a weighted least squares linear regression was used for the calibration method. The evaluated analytical parameters were satisfactory for the analytes and showed recoveries at four fortification levels between 62% and 107%, with relative standard deviations less than 14%. The detection limits ranged from 7.6 to 24.1 ng L(-1). The proposed method was used to determine the amount of UV filters in water samples from water treatment plants in Araraquara and Jau in São Paulo, Brazil. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Classification of Argentinean Sauvignon blanc wines by UV spectroscopy and chemometric methods.

    Science.gov (United States)

    Azcarate, Silvana Mariela; Cantarelli, Miguel Ángel; Pellerano, Roberto Gerardo; Marchevsky, Eduardo Jorge; Camiña, José Manuel

    2013-03-01

    Argentina is an important worldwide wine producer. In this country, there are several recognizable provinces that produce Sauvignon blanc wines: Neuquén, Río Negro, Mendoza, and San Juan. The analysis of the provenance of these white wines is complex and requires the use of expensive and time-consuming techniques. For this reason, this work discusses the determination of the provenance of Argentinean Sauvignon blanc wines by the use of UV spectroscopy and chemometric methods, such as principal component analysis (PCA), cluster analysis (CA), linear discriminant analysis (LDA), and partial least square discriminant analysis (PLS-DA). The proposed method requires low-cost equipment and short-time analysis in comparison with other techniques. The results are in very good agreement with results based on the geographical origin of Sauvignon blanc wines. This manuscript describes a method to determine the geographical origin of Sauvignon wines from Argentina. The main advantage of this method is the use of nonexpensive techniques, such as UV-Vis spectroscopy. © 2013 Institute of Food Technologists®

  16. The method of purification of waste water of NPS from petroleum oil using UV-radiation

    International Nuclear Information System (INIS)

    Kulemin, V.V.; Kareta, V.I.

    1993-01-01

    The main methods of concentration and purification of radioactive waste water of russian NPS are distillation and ion exchange. When waste water containing petroleum oil and washing matter is distillated, part of petroleum and washing matters go to the condensate. The purification of this condensate leads to pollution of ion exchange resins by petroleum oil and reduction of the filter cycle number. The purification of condensate of Russian NPS from petroleum oil is carried out using active carbon and polymer filters, but this process is not effective and fails to give pure condensate. Therefore, the authors began to search for more effective methods of purification of waste water from petroleum oil. They found that UV-radiation makes it possible to purify water from petroleum matter to concentration of the organic phase less than 0.5 mg/dm3. In this process of purification the air, contained in the water phase, was used as an oxidant. When purification is carried out in the absence of sorbents, the quantity of radioactive solid waste, which have to be recovered, decreases. During the study of purification of waste water it was found that increasing of the temperature of the process increases the rate of UV-radiation-induced oxidation of organic phase. The increase in the initial concentration of petroleum products also increases the rate of petroleum oil decomposition. The content of ions in water phase decreases the purification rate. The investigations were carried out on the laboratory scale with water and condensate from Tver's NPS

  17. Evaluation of Biologically Active Compounds from Calendula officinalis Flowers using Spectrophotometry

    Directory of Open Access Journals (Sweden)

    Butnariu Monica

    2012-04-01

    Full Text Available Abstract Background This study aimed to quantify the active biological compounds in C. officinalis flowers. Based on the active principles and biological properties of marigolds flowers reported in the literature, we sought to obtain and characterize the molecular composition of extracts prepared using different solvents. The antioxidant capacities of extracts were assessed by using spectrophotometry to measure both absorbance of the colorimetric free radical scavenger 2,2-diphenyl-1-picrylhydrazyl (DPPH as well as the total antioxidant potential, using the ferric reducing power (FRAP assay. Results Spectrophotometric assays in the ultraviolet-visible (UV-VIS region enabled identification and characterization of the full range of phenolic and flavonoids acids, and high-performance liquid chromatography (HPLC was used to identify and quantify phenolic compounds (depending on the method of extraction. Methanol ensured more efficient extraction of flavonoids than the other solvents tested. Antioxidant activity in methanolic extracts was correlated with the polyphenol content. Conclusions The UV-VIS spectra of assimilator pigments (e.g. chlorophylls, polyphenols and flavonoids extracted from the C. officinalis flowers consisted in quantitative evaluation of compounds which absorb to wavelengths broader than 360 nm.

  18. Advances in analytical methods and occurrence of organic UV-filters in the environment — A review

    International Nuclear Information System (INIS)

    Ramos, Sara; Homem, Vera; Alves, Arminda; Santos, Lúcia

    2015-01-01

    UV-filters are a group of compounds designed mainly to protect skin against UVA and UVB radiation, but they are also included in plastics, furniture, etc., to protect products from light damage. Their massive use in sunscreens for skin protection has been increasing due to the awareness of the chronic and acute effects of UV radiation. Some organic UV-filters have raised significant concerns in the past few years for their continuous usage, persistent input and potential threat to ecological environment and human health. UV-filters end up in wastewater and because wastewater treatment plants are not efficient in removing them, lipophilic compounds tend to sorb onto sludge and hydrophilics end up in river water, contaminating the existing biota. To better understand the risk associated with UV-filters in the environment a thorough review regarding their physicochemical properties, toxicity and environmental degradation, analytical methods and their occurrence was conducted. Higher UV-filter concentrations were found in rivers, reaching 0.3 mg/L for the most studied family, the benzophenone derivatives. Concentrations in the ng to μg/L range were also detected for the p-aminobenzoic acid, cinnamate, crylene and benzoyl methane derivatives in lake and sea water. Although at lower levels (few ng/L), UV-filters were also found in tap and groundwater. Swimming pool water is also a sink for UV-filters and its chlorine by-products, at the μg/L range, highlighting the benzophenone and benzimidazole derivatives. Soils and sediments are not frequently studied, but concentrations in the μg/L range have already been found especially for the benzophenone and crylene derivatives. Aquatic biota is frequently studied and UV-filters are found in the ng/g-dw range with higher values for fish and mussels. It has been concluded that more information regarding UV-filter degradation studies both in water and sediments is necessary and environmental occurrences should be monitored more

  19. Advances in analytical methods and occurrence of organic UV-filters in the environment — A review

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Sara; Homem, Vera, E-mail: vhomem@fe.up.pt; Alves, Arminda; Santos, Lúcia

    2015-09-01

    UV-filters are a group of compounds designed mainly to protect skin against UVA and UVB radiation, but they are also included in plastics, furniture, etc., to protect products from light damage. Their massive use in sunscreens for skin protection has been increasing due to the awareness of the chronic and acute effects of UV radiation. Some organic UV-filters have raised significant concerns in the past few years for their continuous usage, persistent input and potential threat to ecological environment and human health. UV-filters end up in wastewater and because wastewater treatment plants are not efficient in removing them, lipophilic compounds tend to sorb onto sludge and hydrophilics end up in river water, contaminating the existing biota. To better understand the risk associated with UV-filters in the environment a thorough review regarding their physicochemical properties, toxicity and environmental degradation, analytical methods and their occurrence was conducted. Higher UV-filter concentrations were found in rivers, reaching 0.3 mg/L for the most studied family, the benzophenone derivatives. Concentrations in the ng to μg/L range were also detected for the p-aminobenzoic acid, cinnamate, crylene and benzoyl methane derivatives in lake and sea water. Although at lower levels (few ng/L), UV-filters were also found in tap and groundwater. Swimming pool water is also a sink for UV-filters and its chlorine by-products, at the μg/L range, highlighting the benzophenone and benzimidazole derivatives. Soils and sediments are not frequently studied, but concentrations in the μg/L range have already been found especially for the benzophenone and crylene derivatives. Aquatic biota is frequently studied and UV-filters are found in the ng/g-dw range with higher values for fish and mussels. It has been concluded that more information regarding UV-filter degradation studies both in water and sediments is necessary and environmental occurrences should be monitored more

  20. evaluation of atomic absorption spectrophotometry (ashing, non ...

    African Journals Online (AJOL)

    cistvr

    1Department of Agricultural and Food Science and 2Department of ... used techniques, namely atomic absorption spectrophotometry (AAS-Ashing and ..... fact that more preparation steps were involved in the Ashing procedure and thus.

  1. Spectrophotometry of transuranium elements in reprocessing

    International Nuclear Information System (INIS)

    Cauchetier, P.; Guichard, C.; Wagner, J.F.

    1985-06-01

    Quantitative determination of U, Pu and Np at different oxidation degrees by spectrophotometry and problems encountered for industrial applications and automation are reviewed. Work in progress includes memorization of reference spectra, simplification of preliminary treatments of solutions [fr

  2. Validated UV-spectrophotometric method for the evaluation of the efficacy of makeup remover.

    Science.gov (United States)

    Charoennit, P; Lourith, N

    2012-04-01

    A UV-spectrophotometric method for the analysis of makeup remover was developed and validated according to ICH guidelines. Three makeup removers for which the main ingredients consisted of vegetable oil (A), mineral oil and silicone (B) and mineral oil and water (C) were sampled in this study. Ethanol was the optimal solvent because it did not interfere with the maximum absorbance of the liquid foundation at 250 nm. The linearity was determined over a range of makeup concentrations from 0.540 to 1.412 mg mL⁻¹ (R² = 0.9977). The accuracy of this method was determined by analysing low, intermediate and high concentrations of the liquid foundation and gave 78.59-91.57% recoveries with a relative standard deviation of makeup remover efficacy. © 2011 The Authors. ICS © 2011 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  3. The evaluation of a novel method comparing quantitative light-induced fluorescence (QLF) with spectrophotometry to assess staining and bleaching of teeth

    NARCIS (Netherlands)

    Adeyemi, A.A.; Jarad, F.D.; de Josselin de Jong, E.; Pender, N.; Higham, S.M.

    2010-01-01

    This study reports the development and evaluation of a novel method using quantitative light-induced fluorescence (QLF), which enables its use for quantifying and assessing whole tooth surface staining and tooth whitening. The method was compared with a spectrophotometer to assess reliability. Two

  4. Absolute spectrophotometry of Nova Cygni 1975

    International Nuclear Information System (INIS)

    Kontizas, E.; Kontizas, M.; Smyth, M.J.

    1976-01-01

    Radiometric photoelectric spectrophotometry of Nova Cygni 1975 was carried out on 1975 August 31, September 2, 3. α Lyr was used as reference star and its absolute spectral energy distribution was used to reduce the spectrophotometry of the nova to absolute units. Emission strengths of Hα, Hβ, Hγ (in W cm -2 ) were derived. The Balmer decrement Hα:Hβ:Hγ was compared with theory, and found to deviate less than had been reported for an earlier nova. (author)

  5. Novel UV-emitting single crystalline film phosphors grown by LPE method

    International Nuclear Information System (INIS)

    Zorenko, Y.; Gorbenko, V.; Savchyn, V.; Voznyak, T.; Nikl, M.; Mares, J.A.; Winnacker, A.

    2010-01-01

    This work reports the development of new types of UV-emitting phosphors based on single crystalline films (SCF) of aluminum garnet and perovskite compounds grown by the liquid phase epitaxy method. We consider peculiarities of the growth and the luminescent and scintillation properties of the following four types of UV SCF phosphors: i) Ce-doped SCF of Y-Lu-Al-perovskites with the Ce 3+ emission in the 300-450 nm range of the decay time of 16-17 ns; ii) Pr-doped SCF of Y-Lu-Al garnets and perovskites with the Pr 3+ emission in the 300-400 nm and 235-330 nm ranges with the decay time of 13-19 and 7-8 ns, respectively; iii) La 3+ or Sc 3+ doped SCF of Y-Lu-Al-garnets, emitting in the 280-400 nm range due to formation of the La Y,Lu , Sc Y,Lu and Sc Al centers with decay time of the order of several hundreds of nanoseconds; iv) Bi 3+ doped SCF of garnets with Bi 3+ emission in 275-350 nm with decay time of about 1.9 μs.

  6. A method for optimizing the cosine response of solar UV diffusers

    Science.gov (United States)

    Pulli, Tomi; Kärhä, Petri; Ikonen, Erkki

    2013-07-01

    Instruments measuring global solar ultraviolet (UV) irradiance at the surface of the Earth need to collect radiation from the entire hemisphere. Entrance optics with angular response as close as possible to the ideal cosine response are necessary to perform these measurements accurately. Typically, the cosine response is obtained using a transmitting diffuser. We have developed an efficient method based on a Monte Carlo algorithm to simulate radiation transport in the solar UV diffuser assembly. The algorithm takes into account propagation, absorption, and scattering of the radiation inside the diffuser material. The effects of the inner sidewalls of the diffuser housing, the shadow ring, and the protective weather dome are also accounted for. The software implementation of the algorithm is highly optimized: a simulation of 109 photons takes approximately 10 to 15 min to complete on a typical high-end PC. The results of the simulations agree well with the measured angular responses, indicating that the algorithm can be used to guide the diffuser design process. Cost savings can be obtained when simulations are carried out before diffuser fabrication as compared to a purely trial-and-error-based diffuser optimization. The algorithm was used to optimize two types of detectors, one with a planar diffuser and the other with a spherically shaped diffuser. The integrated cosine errors—which indicate the relative measurement error caused by the nonideal angular response under isotropic sky radiance—of these two detectors were calculated to be f2=1.4% and 0.66%, respectively.

  7. Development of a method for the characterization and operation of UV-LED for water treatment.

    Science.gov (United States)

    Kheyrandish, Ataollah; Mohseni, Madjid; Taghipour, Fariborz

    2017-10-01

    Tremendous improvements in semiconductor technology have made ultraviolet light-emitting diodes (UV-LEDs) a viable alternative to conventional UV sources for water treatment. A robust and validated experimental protocol for studying the kinetics of microorganism inactivation is key to the further development of UV-LEDs for water treatment. This study proposes a protocol to operate UV-LEDs and control their output as a polychromatic radiation source. In order to systematically develop this protocol, the results of spectral power distribution, radiation profile, and radiant power measurements of a variety of UV-LEDs are presented. A wide range of UV-LEDs was selected for this study, covering various UVA, UVB, and UVC wavelengths, viewing angles from 3.5° to 135°, and a variety of output powers. The effects of operational conditions and measurement techniques were investigated on these UV-LEDs using a specially designed and fabricated setup. Operating conditions, such as the UV-LED electrical current and solder temperature, were found to significantly affect the power and peak wavelength output. The measurement techniques and equipment, including the detector size, detector distance from the UV-LED, and potential reflection from the environment, were shown to influence the results for many of the UV-LEDs. The results obtained from these studies were analyzed and applied to the development of a protocol for UV-LED characterization. This protocol is presented as a guideline that allows the operation and control of UV-LEDs in any structure, as well as accurately measuring the UV-LED output. Such information is essential for performing a reliable UV-LED assessment for the inactivation of microorganisms and for obtaining precise kinetic data. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Quantification of naphazoline nitrate by UV-spectrophoto-metry

    Directory of Open Access Journals (Sweden)

    O. I. Panasenko

    2013-12-01

    Full Text Available One of the main tasks of pharmaceutical chemistry – medical drugs study. Spectrophotometry is widely used in studying of the structure and composition (complexes, dyes, analytical reagents, etc. of various compounds. It widely used for qualitative and quantitative determination of substances (determination of elements traces in metals, alloys, technical facilities. The dependence between substance structure and its electronic spectrum is being studied by many researchers till nowadays. The aim of this work was to highlight the issues of naphazoline quantify definition techniques by the UV-spectrophotometry. According to the existing methods of quality control (MQC, naphazoline nitrate is a substance quantitatively determined by acid-base titration among a mixture of anhydrous acetic acid and acetic anhydride. Titration is carried out with a solution of 0,1 M perchloric acid (indicator - crystal violet. To check the quality of nasal drops nafazoline nitrate MQC is recommended UV-spectrophotometry: drug is dissolved in boric acid solution (20 g/l as the reference solution used solution pharmacopoeia standard sample substance nafazoline nitrate. The character of UV-spectra of the nafazoline nitrate in solvents of different polarity (water, 95% ethanol, 0,1 M NaOH, 0,1 M HCl, 5M H2SO4, was defined and studied. Standard sample of nafazoline nitrate was obtained from the State Enterprise "Scientific and Expert Pharmacopoeia Centre Ukraine". In order to study UV-spectra nafazoline nitrate spectrophotometer SPECORD 200-222U214 (Germany was used. UV-spectrum of nafazoline nitrate in water and 95% ethanol are characterized by two maxima at 270 and 280 nm. Absorption band of nafazoline nitrate in 0, 1 M sodium hydroxide has two maxima at 271 and 280 nm, and in 0, 1 M solution of hydrochloric acid and 5 M solution of sulfuric acid maxima coincide with the maxima spectrum of the drug in water, 95% ethanol. In order to avoid errors associated with

  9. New model for prediction binary mixture of antihistamine decongestant using artificial neural networks and least squares support vector machine by spectrophotometry method

    Science.gov (United States)

    Mofavvaz, Shirin; Sohrabi, Mahmoud Reza; Nezamzadeh-Ejhieh, Alireza

    2017-07-01

    In the present study, artificial neural networks (ANNs) and least squares support vector machines (LS-SVM) as intelligent methods based on absorption spectra in the range of 230-300 nm have been used for determination of antihistamine decongestant contents. In the first step, one type of network (feed-forward back-propagation) from the artificial neural network with two different training algorithms, Levenberg-Marquardt (LM) and gradient descent with momentum and adaptive learning rate back-propagation (GDX) algorithm, were employed and their performance was evaluated. The performance of the LM algorithm was better than the GDX algorithm. In the second one, the radial basis network was utilized and results compared with the previous network. In the last one, the other intelligent method named least squares support vector machine was proposed to construct the antihistamine decongestant prediction model and the results were compared with two of the aforementioned networks. The values of the statistical parameters mean square error (MSE), Regression coefficient (R2), correlation coefficient (r) and also mean recovery (%), relative standard deviation (RSD) used for selecting the best model between these methods. Moreover, the proposed methods were compared to the high- performance liquid chromatography (HPLC) as a reference method. One way analysis of variance (ANOVA) test at the 95% confidence level applied to the comparison results of suggested and reference methods that there were no significant differences between them.

  10. Improving the submicro determination of vanadium in natural water using primary-secondary wavelength spectrophotometry

    International Nuclear Information System (INIS)

    Khongven Gao

    1999-01-01

    In acidic solution and in the presence of ammonium persulfate, the conventional reaction of vanadium(5) with gallic acid to form an orange complex has been used for the improvement of the determination of trace amounts of vanadium in water by the updated method named primary-secondary wavelength spectrophotometry. The results show that the analytical precision and accuracy were improved and gave higher determination sensitivity than ordinary spectrophotometry. The relative standard deviations were less than 5.6 % [ru

  11. Quantitative analysis of active compounds in pharmaceutical preparations by use of attenuated total-reflection Fourier transform mid-infrared spectrophotometry and the internal standard method.

    Science.gov (United States)

    Sastre Toraño, J; van Hattum, S H

    2001-10-01

    A new method is presented for the quantitative analysis of compounds in pharmaceutical preparations Fourier transform (FT) mid-infrared (MIR) spectroscopy with an attenuated total reflection (ATR) module. Reduction of the quantity of overlapping absorption bands, by interaction of the compound of interest with an appropriate solvent, and the employment of an internal standard (IS), makes MIR suitable for quantitative analysis. Vigabatrin, as active compound in vigabatrin 100-mg capsules, was used as a model compound for the development of the method. Vigabatrin was extracted from the capsule content with water after addition of a sodium thiosulfate IS solution. The extract was concentrated by volume reduction and applied to the FTMIR-ATR module. Concentrations of unknown samples were calculated from the ratio of the vigabatrin band area (1321-1610 cm(-1)) and the IS band area (883-1215 cm(-1)) using a calibration standard. The ratio of the area of the vigabatrin peak to that of the IS was linear with the concentration in the range of interest (90-110 mg, in twofold; n=2). The accuracy of the method in this range was 99.7-100.5% (n=5) with a variability of 0.4-1.3% (n=5). The comparison of the presented method with an HPLC assay showed similar results; the analysis of five vigabatrin 100-mg capsules resulted in a mean concentration of 102 mg with a variation of 2% with both methods.

  12. An improved UHPLC-UV method for separation and quantification of carotenoids in vegetable crops.

    Science.gov (United States)

    Maurer, Megan M; Mein, Jonathan R; Chaudhuri, Swapan K; Constant, Howard L

    2014-12-15

    Carotenoid identification and quantitation is critical for the development of improved nutrition plant varieties. Industrial analysis of carotenoids is typically carried out on multiple crops with potentially thousands of samples per crop, placing critical needs on speed and broad utility of the analytical methods. Current chromatographic methods for carotenoid analysis have had limited industrial application due to their low throughput, requiring up to 60 min for complete separation of all compounds. We have developed an improved UHPLC-UV method that resolves all major carotenoids found in broccoli (Brassica oleracea L. var. italica), carrot (Daucus carota), corn (Zea mays), and tomato (Solanum lycopersicum). The chromatographic method is completed in 13.5 min allowing for the resolution of the 11 carotenoids of interest, including the structural isomers lutein/zeaxanthin and α-/β-carotene. Additional minor carotenoids have also been separated and identified with this method, demonstrating the utility of this method across major commercial food crops. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Method 446.0: In Vitro Determination of Chlorophylls a, b, c + c and Pheopigments in 1 2Marine And Freshwater Algae by Visible Spectrophotometry

    Science.gov (United States)

    This method provides a procedure for determination of chlorophylls a (chl a), b (chl b), c + c 1 2 (chl c + c ) and pheopigments of chlorophyll a (pheo a) 1 2 found in marine and freshwater phytoplankton. Chlorophyllide a is determined as chl a. Visible wavelength spectrophotomet...

  14. A simple and rapid method for measurement of 10B-para-boronophenylalanine in the blood for boron neutron capture therapy using fluorescence spectrophotometry

    International Nuclear Information System (INIS)

    Kashino, Genro; Fukutani, Satoshi; Suzuki, Minoru

    2009-01-01

    10 B deriving from 10 B-para-boronophenylalanine (BPA) and 10 B-borocaptate sodium (BSH) have been detected in blood samples of patients undergoing boron neutron capture therapy (BNCT) using prompt gamma ray spectrometer or Inductively Coupled Plasma (ICP) method, respectively. However, the concentration of each compound cannot be ascertained because boron atoms in both molecules are the target in these assays. Here, we propose a simple and rapid method to measure only BPA by detecting fluorescence based on the characteristics of phenylalanine. 10 B concentrations of blood samples from human or mice were estimated by the fluorescence intensities at 275 nm of a BPA excited by light of wavelength 257 nm using a fluorescence spectrophotometer. The relationship between fluorescence to increased BPA concentration showed a positive linear correlation. Moreover, we established an adequate condition for BPA measurement in blood samples containing BPA, and the estimated 10 B concentrations of blood samples derived from BPA treated mice were similar between the values obtained by our method and those by ICP method. This new assay will be useful to estimate BPA concentration in blood samples obtained from patients undergoing BNCT especially in a combination use of BSH and BPA. (author)

  15. Characteristics and performance of the Sunna high dose dosemeter using green photoluminescence and UV absorption readout methods

    Energy Technology Data Exchange (ETDEWEB)

    Miller, S.D.; Murphy, M.K.; Tinker, M.R.; Kovacs, A.; McLaughlin, W

    2002-07-01

    Growth in the use of ionising radiation for medical sterilisation and the potential for wide-scale international food irradiation have created the need for robust, mass-producible, inexpensive, and highly accurate radiation dosemeters. The Sunna dosemeter, lithium fluoride injection-moulded in a polyethylene matrix, can be read out using either green photoluminescence or ultraviolet (UV) absorption. The Sunna dosemeter can be mass-produced inexpensively with high precision. Both the photoluminescent and the UV absorption reader are simple and inexpensive. Both methods of analysis display negligible humidity effects, minimal dose rate dependence, acceptable post-irradiation effects, and permit measurements with a precision of nearly 1% 1s. The UV method shows negligible irradiation temperature effects from -30 deg. C to +60 deg. C. The photoluminescence method shows negligible irradiation temperature effects above room temperature for sterilisation dose levels and above. The dosimetry characteristics of these two readout methods are presented along with performance data in commercial sterilisation facilities. (author)

  16. Spectrophotometry of cerebrospinal fluid in subacute and chronic subdural haematomas

    Science.gov (United States)

    Kjellin, K. G.; Steiner, L.

    1974-01-01

    Spectrophotometric examinations were performed on cerebrospinal and subdural fluids in subacute (five patients) and chronic (20 patients) subdural haematomas, with special reference to the diagnostic aid of CSF spectrophotometry. Spectrophotometric xanthochromia of haemorrhagic origin was found in all CSFs examined, while definite visible xanthochromia was observed in only 28% and the CSF was judged as colourless in 52% of those cases. Characteristic bleeding patterns were found spectrophotometrically in all the 20 CSFs examined within 24 hours after lumbar puncture, haematoma patterns being detected in 90-95% of the cases. In many cases the electrophoretically separated protein fractions of CSF and subdural fluids were spectrophotometrically examined. In conclusion, CSF spectrophotometry is a simple, fast, and extremely sensitive method, which in our opinion should be used routinely in the diagnosis of suspected subdural haematomas, if lumbar puncture is not contraindicated. PMID:4140892

  17. Method for determining microamounts of uranium in solutions from copper ores, by liquid-liquid extraction and spectrophotometry with arsenazo III

    International Nuclear Information System (INIS)

    Rodriguez, B.

    1972-01-01

    A spectrophotometric method is described for determining small amounts of uranium in aqueous solutions from copper ores. Uranium is quantitatively separated in a single extraction by a solution of tri-n-octylphosphine oxide in benzene, using ethylendiaminetetracetic acid and sodium fluoride as complexing agents, for improving the selectivity of the procedure. An aliquot of the extract is diluted with a hydrocolloidal solution of arsenazo III. Optical density is measured at 650 nm. (Author) 3 refs

  18. Review of UV spectroscopic, chromatographic, and electrophoretic methods for the cholinesterase reactivating antidote pralidoxime (2-PAM).

    Science.gov (United States)

    John, Harald; Blum, Marc-Michael

    2012-01-01

    Pralidoxime (2-PAM) belongs to the class of monopyridinium oximes with reactivating potency on cholinesterases inhibited by phosphylating organophosphorus compounds (OPC), for example, pesticides and nerve agents. 2-PAM represents an established antidote for the therapy of anticholinesterase poisoning since the late 1950s. Quite high therapeutic concentrations in human plasma (about 13 µg/ml) lead to concentrations in urine being about 100 times higher allowing the use of less sensitive analytical techniques that were used especially in the early years after 2-PAM was introduced. In this time (mid-1950s until the end of the 1970s) 2-PAM was most often analyzed by either paper chromatography or simple UV spectroscopic techniques omitting any sample separation step. These methods were displaced completely after the establishment of column liquid chromatography in the early 1980s. Since then, diverse techniques including cation exchange, size-exclusion, reversed-phase, and ligand-exchange chromatography have been introduced. Today, the most popular method for 2-PAM quantification is ion pair chromatography often combined with UV detection representing more than 50% of all column chromatographic procedures published. Furthermore, electrophoretic approaches by paper and capillary zone electrophoresis have been successfully used but are seldom applied. This review provides a commentary and exhaustive summary of analytical techniques applied to detect 2-PAM in pharmaceutical formulations and biological samples to characterize stability and pharmacokinetics as well as decomposition and biotransformation products. Separation techniques as well as diverse detectors are discussed in appropriate detail allowing comparison of individual preferences and limitations. In addition, novel data on mass spectrometric fragmentation of 2-PAM are provided. Copyright © 2011 John Wiley & Sons, Ltd.

  19. Optimization, validation and application of UV-Vis spectrophotometric-colorimetric methods for determination of trimethoprim in different medicinal products

    Directory of Open Access Journals (Sweden)

    Goran Stojković

    2016-03-01

    Full Text Available Two simple, sensitive, selective, precise, and accurate methods for determination of trimethoprim in different sulfonamide formulations intended for use in human and veterinary medicine were optimized and validated. The methods are based on the trimethoprim reaction with bromcresol green (BCG and 2,4-dinitro-1-fluorobenzene (DNFB. As extraction solvents we used 10 % N,N-dimethylacetamide in methanol and acetone for both methods, respectively. The colored products are quantified applying visible spectrophotometry at their corresponding absorption maxima. The methods were validated for linearity, sensitivity, accuracy, and precision. We tested the method applicability on four different medicinal products in tablet and powder forms containing sulfametrole and sulfamethoxazole in combination with trimethoprim. The results revealed that both methods are equally accurate with recoveries within the range 95-105 %. The obtained between-day precision for both methods, when applied on four different medicinal products, was within in the range 1.08-3.20 %. By applying the F-statistical test (P<0.05, it was concluded that for three medicinal products tested both methods are applicable with statistically insignificant difference in precision. The optimized and validated BCG and DNFB methods could find application in routine quality control of trimethoprim in various formulation forms, at different concentration levels, and in combination with different sulfonamides.

  20. A Highly Sensitive and Selective Method for the Determination of an Iodate in Table-salt Samples Using Malachite Green-based Spectrophotometry.

    Science.gov (United States)

    Konkayan, Mongkol; Limchoowong, Nunticha; Sricharoen, Phitchan; Chanthai, Saksit

    2016-01-01

    A simple, rapid, and sensitive malachite green-based spectrophotometric method for the selective trace determination of an iodate has been developed and presented for the first time. The reaction mixture was specifically involved in the liberation of iodine in the presence of an excess of iodide in an acidic condition following an instantaneous reaction between the liberated iodine and malachite green dye. The optimum condition was obtained with a buffer solution pH of 5.2 in the presence of 40 mg L -1 potassium iodide and 1.5 × 10 -5 M malachite green for a 5-min incubation time. The iodate contents in some table-salt samples were in the range of 26 to 45 mg kg -1 , while those of drinking water, tap water, canal water, and seawater samples were not detectable (< 96 ng mL -1 of limits of detection, LOQ) with their satisfied method of recoveries of between 93 and 108%. The results agreed with those obtained using ICP-OES for comparison.

  1. Validation of a UV Spectrometric Method for the Assay of Tolfenamic Acid in Organic Solvents

    Directory of Open Access Journals (Sweden)

    Sofia Ahmed

    2015-01-01

    Full Text Available The present study has been carried out to validate a UV spectrometric method for the assay of tolfenamic acid (TA in organic solvents. TA is insoluble in water; therefore, a total of thirteen commonly used organic solvents have been selected in which the drug is soluble. Fresh stock solutions of TA in each solvent in a concentration of 1 × 10−4 M (2.62 mg% were prepared for the assay. The method has been validated according to the guideline of International Conference on Harmonization and parameters like linearity, range, accuracy, precision, sensitivity, and robustness have been studied. Although the method was found to be efficient for the determination of TA in all solvents on the basis of statistical data 1-octanol, followed by ethanol and methanol, was found to be comparatively better than the other studied solvents. No change in the stock solution stability of TA has been observed in each solvent for 24 hours stored either at room (25±1°C or at refrigerated temperature (2–8°C. A shift in the absorption maxima has been observed for TA in various solvents indicating drug-solvent interactions. The studied method is simple, rapid, economical, accurate, and precise for the assay of TA in different organic solvents.

  2. Optimizing adsorption of blue pigment from wastewater by nano-porous modified Na-bentonite using spectrophotometry based on response surface method

    Science.gov (United States)

    Moradi, Neshat; Salem, Shiva; Salem, Amin

    2018-03-01

    This work highlighted the effective activation of bentonite paste to produce nano-porous powder for removal of cationic dye from wastewater. The effects of activation parameters such as soda and moisture contents, ageing time and temperature were analyzed using response surface methodology (RSM). The significance of independent variables and their interactions were tested by blending the obtained powders with wastewater and then the adsorption was evaluated, spectrophotometrically. The experiments were carried out by preparation of pastes according to response surface methodology and central composite design, which is the standard method, was used to evaluate the effects and interactions of four factors on the treatment efficiency. RSM was demonstrated as an appropriate approach for optimization of alkali activation. The optimal conditions obtained from the desirable responses were 5.0 wt% soda and 45.0 wt% moisture, respectively in which the powder activation was carried out at 150 °C. In order to well understand the role of nano-structured material on dye removal, the adsorbents were characterized through X-ray diffraction, Fourier transform infrared spectroscopy, scanning electron microscopy and Brunauer-Emmett-Teller surface area measurement. Finally, the analysis clearly demonstrates that the dye removal onto prepared adsorbent is well fitted with Langmuir isotherm compared to the other isotherm models. The low cost of material and facile process support the further development for commercial application purpose.

  3. Determination of Oxytetracycline from Salmon Muscle and Skin by Derivative Spectrophotometry.

    Science.gov (United States)

    Toral, M Inés; Sabay, Tamara; Orellana, Sandra L; Richter, Pablo

    2015-01-01

    A method was developed for the identification and quantification of oxytetracycline residues present in salmon muscle and skin using UV-Vis derivative spectrophotometry. With this method, it was possible to reduce the number of steps in the procedure typically required for instrumental analysis of a sample. The spectral variables, order of the derivative, scale factor, smoothing factor, and analytical wavelength were optimized using standard solutions of oxytetracycline dissolved in 900 mg/L oxalic acid in methanol. The matrix effect was significant; therefore, quantification for oxytetracycline residues was carried out using drug-free salmon muscle and skin samples fortified with oxytetracycline. The LOD and LOQ were found to be 271 and 903 μg/kg, respectively. The precision and accuracy of the method were validated using drug-free salmon muscle and skin tissues fortified at three different concentrations (8, 16, and 32 mg/kg) on 3 different days. The recoveries at all fortified concentrations were between 90 and 105%, and RSDs in all cases were less than 6.5%. This method can be used to screen out compliant samples and thereby reduce the number of suspect positive samples that will require further confirmatory analysis.

  4. Determination of benzodiazepines in beverages using green extraction methods and capillary HPLC-UV detection.

    Science.gov (United States)

    Piergiovanni, Maurizio; Cappiello, Achille; Famiglini, Giorgio; Termopoli, Veronica; Palma, Pierangela

    2018-05-30

    Dispersive liquid-liquid microextraction with and without ultrasound assistance (DLLME, UA-DLLME) and microextraction with packed sorbent (MEPS) methods for the extraction and determination of eight different benzodiazepines (BDZ) (chlordiazepoxide, flurazepam, bromazepam, oxazepam, lorazepam, clobazam, clonazepam, and flunitrazepam) in three commercial non-alcoholic and light alcoholic beverages were optimized and compared. Benzodiazepines are frequently used for their extensive diffusion and strong numbing effect in drug-facilitated crimes (DFC). The tiny small amount of sample required for DLLME and MEPS extraction makes them very suitable for specimens collected at the crime scene of DFCs. Microextraction techniques are of increasing interest thanks to their accordance to green analytical chemistry (GAC) guidelines providing good recovery values. Ultrasound assistance (UA-DLLME) was used to investigate whether this type of energy can improve the recoveries of the analytes. Analyses of the extracts were performed with reverse-phase capillary high-performance liquid chromatography with UV detection (HPLC - UV), thanks to low environmental impact, robustness, diffusion, and affordability. Recovery percentages at three different concentrations in the three beverages were between 14.30% and 103.28% with intraday and interday RSD lower than ±2.78%. The same samples were extracted using a MEPS protocol, and the results were compared with those obtained with DLLME. MEPS gave recoveries between 20.90% and 101.88% for all matrices showing a better performance than DLLME at higher concentrations, though lower recoveries were observed with diluted samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Validation of an ultra-fast UPLC-UV method for the separation of antituberculosis tablets.

    Science.gov (United States)

    Nguyen, Dao T-T; Guillarme, Davy; Rudaz, Serge; Veuthey, Jean-Luc

    2008-04-01

    A simple method using ultra performance LC (UPLC) coupled with UV detection was developed and validated for the determination of antituberculosis drugs in combined dosage form, i. e. isoniazid (ISN), pyrazinamide (PYR) and rifampicin (RIF). Drugs were separated on a short column (2.1 mm x 50 mm) packed with 1.7 mum particles, using an elution gradient procedure. At 30 degrees C, less than 2 min was necessary for the complete separation of the three antituberculosis drugs, while the original USP method was performed in 15 min. Further improvements were obtained with the combination of UPLC and high temperature (up to 90 degrees C), namely HT-UPLC, which allows the application of higher mobile phase flow rates. Therefore, the separation of ISN, PYR and RIF was performed in less than 1 min. After validation (selectivity, trueness, precision and accuracy), both methods (UPLC and HT-UPLC) have proven suitable for the routine quality control analysis of antituberculosis drugs in combined dosage form. Additionally, a large number of samples per day can be analysed due to the short analysis times.

  6. Quantitative methods for structural characterization of proteins based on deep UV resonance Raman spectroscopy.

    Science.gov (United States)

    Shashilov, Victor A; Sikirzhytski, Vitali; Popova, Ludmila A; Lednev, Igor K

    2010-09-01

    Here we report on novel quantitative approaches for protein structural characterization using deep UV resonance Raman (DUVRR) spectroscopy. Specifically, we propose a new method combining hydrogen-deuterium (HD) exchange and Bayesian source separation for extracting the DUVRR signatures of various structural elements of aggregated proteins including the cross-beta core and unordered parts of amyloid fibrils. The proposed method is demonstrated using the set of DUVRR spectra of hen egg white lysozyme acquired at various stages of HD exchange. Prior information about the concentration matrix and the spectral features of the individual components was incorporated into the Bayesian equation to eliminate the ill-conditioning of the problem caused by 100% correlation of the concentration profiles of protonated and deuterated species. Secondary structure fractions obtained by partial least squares (PLS) and least squares support vector machines (LS-SVMs) were used as the initial guess for the Bayessian source separation. Advantages of the PLS and LS-SVMs methods over the classical least squares calibration (CLSC) are discussed and illustrated using the DUVRR data of the prion protein in its native and aggregated forms. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  7. Simultaneous Chloramphenicol and Florfenicol Determination by A Validated DLLME-HPLC-UV Method in Pasteurized Milk.

    Science.gov (United States)

    Karami-Osboo, Rouhollah; Miri, Ramin; Javidnia, Katayoun; Kobarfard, Farzad

    2016-01-01

    The antibiotic residues in milk are a well-known serious problem and pose several health hazards to consumers. We have described a simple, rapid, and inexpensive DLLME-HPLC/UV technique for the extraction of chloramphenicol and florfenicol residues in milk samples. Under the optimum conditions, linearity of the method was observed over the range 0.02-0.85 µg/L with correlation coefficients > 0.999. The proposed method has been found to have a good limit of detection (signal to noise ratio = 3) for chloramphenicol (12.5 µg/Kg) and florfenicol (12.2 µg/Kg), and precision with relative standard deviation values under 15% (RSD, n = 3). Good recoveries (69.1-79.4%) were obtained for the extraction of the target analytes in milk samples. This simple and economic method has been applied for analyses of 15 real milk samples. Among all samples only one of them was contaminated to florfenicol; 62.4 µg/Kg and contamination to chloramphenicol was not detected.

  8. Stability indicating HPLC-UV method for detection of curcumin in Curcuma longa extract and emulsion formulation.

    Science.gov (United States)

    Syed, Haroon Khalid; Liew, Kai Bin; Loh, Gabriel Onn Kit; Peh, Kok Khiang

    2015-03-01

    A stability-indicating HPLC-UV method for the determination of curcumin in Curcuma longa extract and emulsion was developed. The system suitability parameters, theoretical plates (N), tailing factor (T), capacity factor (K'), height equivalent of a theoretical plate (H) and resolution (Rs) were calculated. Stress degradation studies (acid, base, oxidation, heat and UV light) of curcumin were performed in emulsion. It was found that N>6500, Tcurcumin were ⩽0.87% and ⩽2.0%, while the inter-day precision and accuracy values were ⩽2.1% and ⩽-1.92. Curcumin degraded in emulsion under acid, alkali and UV light. In conclusion, the stability-indicating method could be employed to determine curcumin in bulk and emulsions. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Advances in analytical methods and occurrence of organic UV-filters in the environment--A review.

    Science.gov (United States)

    Ramos, Sara; Homem, Vera; Alves, Arminda; Santos, Lúcia

    2015-09-01

    UV-filters are a group of compounds designed mainly to protect skin against UVA and UVB radiation, but they are also included in plastics, furniture, etc., to protect products from light damage. Their massive use in sunscreens for skin protection has been increasing due to the awareness of the chronic and acute effects of UV radiation. Some organic UV-filters have raised significant concerns in the past few years for their continuous usage, persistent input and potential threat to ecological environment and human health. UV-filters end up in wastewater and because wastewater treatment plants are not efficient in removing them, lipophilic compounds tend to sorb onto sludge and hydrophilics end up in river water, contaminating the existing biota. To better understand the risk associated with UV-filters in the environment a thorough review regarding their physicochemical properties, toxicity and environmental degradation, analytical methods and their occurrence was conducted. Higher UV-filter concentrations were found in rivers, reaching 0.3mg/L for the most studied family, the benzophenone derivatives. Concentrations in the ng to μg/L range were also detected for the p-aminobenzoic acid, cinnamate, crylene and benzoyl methane derivatives in lake and sea water. Although at lower levels (few ng/L), UV-filters were also found in tap and groundwater. Swimming pool water is also a sink for UV-filters and its chlorine by-products, at the μg/L range, highlighting the benzophenone and benzimidazole derivatives. Soils and sediments are not frequently studied, but concentrations in the μg/L range have already been found especially for the benzophenone and crylene derivatives. Aquatic biota is frequently studied and UV-filters are found in the ng/g-dw range with higher values for fish and mussels. It has been concluded that more information regarding UV-filter degradation studies both in water and sediments is necessary and environmental occurrences should be monitored more

  10. [Application of HPLC-UV method for aripiprazole determination in serum].

    Science.gov (United States)

    Synowiec, Anna; Gomółka, Ewa; Zyss, Tomasz; Zieba, Andrzej; Florek, Ewa; Piekoszewski, Wojciech

    2012-01-01

    Aripiprazole is a new drug applied in schizophrenia treatment. There are not strict indications for aripiprazole therapeutic drug monitoring. Despite, serum aripiprazole measuring would help control the drug doses effectiveness. The drug monitoring can eliminate overdosing, adverse effects and let control proper drug ingestion. The aim of the paper was to develop a simple method for aripiprazole determination in serum for therapeutic drug monitoring. High performance liquid chromatography with spectrophotometric detection (HPLC-UV) was used. Resolution was performed on LC-8 column; moving phase was solution 0,025M trimethylammonium buffer: acetonitrile (62:38). Isocratic flow was 1,2 ml/min; internal standard (IS) was promazine; monitored wavelength was lambda=214 nm. The validation parameters were: limits of linearity (LOL) 100-800 ng/ml, limit of detection (LOD) 10 ng/ml, limit of quantity (LOQ) 100 ng/ml. Coefficient of variation (CV) describing accuracy and precision didn't cross 10%. The method was useful for therapeutic drug monitoring in serum of patients treated with aripiprazole.

  11. Photochemical Synthesis of Complex Carbazoles: Evaluation of Electronic Effects in Both UV- and Visible-Light Methods in Continuous Flow.

    Science.gov (United States)

    Hernandez-Perez, Augusto C; Caron, Antoine; Collins, Shawn K

    2015-11-09

    An evaluation of both a visible-light- and UV-light-mediated synthesis of carbazoles from various triarylamines with differing electronic properties under continuous-flow conditions has been conducted. In general, triarylamines bearing electron-rich groups tend to produce higher yields than triarylamines possessing electron-withdrawing groups. The incorporation of nitrogen-based heterocycles, as well as halogen-containing arenes in carbazole skeletons, was well tolerated, and often synthetically useful complementarity was observed between the UV-light and visible-light (photoredox) methods. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Simultaneous determination of sulphaquinoxaline and amprolium in veterinary mixture by HPLC and first derivative ultraviolet spectrophotometry

    International Nuclear Information System (INIS)

    El-Sattar, Osama Abd

    2002-01-01

    Two simple and reliable methods are described for the determination of sulphaquinoxaline (SQX) and amprolium (AMP) combined in veterinary powder. The first method depends on high performance liquid chromatography on a reversed phase column (Bondapak-C18) using mobile phase consisting of acetonitrile-methanol-water-phosphoric acid (30: 5: 55: 0.7, by volumes) at a flow rate of 1 ml min with UV detection at 254 nm. The detection limits were 0.2 ug ml and 0.35 ug ml and linearity ranges were 2-20 ug ml and 4-40ug ml for SQX and AMP, respectively. The second one deals with the first derivative (D) spectrophotometry with zero-crossing measurement at 253 nm and 226 nm for SQX and AMP respectively. The detection limits were 0.3 ug ml and linearity ranges were 1-18 ug ml and 4-32 ug-ml for SQX and AMP respectively. The proposed procedures were successfully applied to the determination of these drugs in laboratory prepared mixtures with mean percentage recovery ranged from 98.50 to 99.75 and in commercial preparation ranged from 103.85 to 104.85. (author)

  13. Review of recent applications of flow injection spectrophotometry to pharmaceutical analysis

    International Nuclear Information System (INIS)

    Tzanavaras, Paraskevas D.; Themelis, Demetrius G.

    2007-01-01

    Pharmaceutical analysis is one of the most important fields in analytical chemistry. The discovery of new drugs and the on-going update of international regulations for the safety and efficacy of pharmaceutical formulations demand the continuous development of new analytical methods. Inevitably, automation plays an important role, especially when a lot of samples have to be analyzed in the minimum of time. The present study reviews the applications of flow injection (FI) spectrophotometry to the determination of active pharmaceutical ingredients (APIs) in their respective formulations. However, the topic covered in this study is important not only to pharmaceutical analytical scientists. The principles, figures of merit and 'chemistry' of the presented methods can be of interest to bio-analytical and clinical chemists as well for the analysis of biological samples, to environmental analysts that study the up-to-date demand of the determination of the fate of pharmaceuticals in the environment and even to toxicologists and forensic scientists. This review covers scientific contributions published later than 2000. A variety of FI procedures based on homogeneous (direct UV measurements, colour-forming reactions, metal-drug interactions) and heterogeneous (optical sensors and solid-phase reactors) systems are discussed. A third section covers on-line sample pretreatment (solid-phase extraction, liquid-liquid extraction, on-line digestion, etc.)

  14. The Adjoint Method for Gradient-based Dynamic Optimization of UV Flash Processes

    DEFF Research Database (Denmark)

    Ritschel, Tobias Kasper Skovborg; Capolei, Andrea; Jørgensen, John Bagterp

    2017-01-01

    This paper presents a novel single-shooting algorithm for gradient-based solution of optimal control problems with vapor-liquid equilibrium constraints. Dynamic optimization of UV flash processes is relevant in nonlinear model predictive control of distillation columns, certain two-phase flow pro......-component flash process which demonstrate the importance of the optimization solver, the compiler, and the linear algebra software for the efficiency of dynamic optimization of UV flash processes....

  15. On a variant of the first derivative technique in spectrophotometry

    International Nuclear Information System (INIS)

    Kvaratskheli, Yu.K.; Pchelkin, V.A.; Demin, Yu.V.; Kukushkin, G.R.

    1981-01-01

    A variant of the first derivative technique in spectrophotometry is suggested which is based on continuous sinusoidal sweep of the wavelength within a narrow spectral region. A spectrophotometer has been designed which records the first derivative (dA/dlambda). A method has been developed of determining uranium (6) with arsenazo 3 in the presence of 20 times its amounts of zirconium thorium or iron (3). The method can be used for spectrophotometric determination of some other elements with different reagents, particularly in the analysis of elements with overlapped absorption spectra [ru

  16. Development of a HPLC method for determination of four UV filters in sunscreen and its application to skin penetration studies.

    Science.gov (United States)

    Souza, Carla; Maia Campos, Patrícia M B G

    2017-12-01

    This study describes the development, validation and application of a high-performance liquid chromatography (HPLC) method for the simultaneous determination of the in vitro skin penetration profile of four UV filters on porcine skin. Experiments were carried out on a gel-cream formulation containing the following UV filters: diethylamino hydroxybenzoyl hexyl benzoate (DHHB), bis-ethylhexyloxyphenol methoxyphenyl triazine (BEMT), methylene bis-benzotriazolyl tetramethylbutylphenol (MBBT) and ethylhexyl triazone (EHT). The HPLC method demonstrated suitable selectivity, linearity (10.0-50.0 μg/mL), precision, accuracy and recovery from porcine skin and sunscreen formulation. The in vitro skin penetration profile was evaluated using Franz vertical diffusion cells for 24 h after application on porcine ear skin. None of the UV filters penetrated the porcine skin. Most of them stayed on the skin surface (>90%) and only BEMT, EHT and DHHB reached the dermis plus epidermis layer. These results are in agreement with previous results in the literature. Therefore, the analytical method was useful to evaluate the in vitro skin penetration of the UV filters and may help the development of safer and effective sunscreen products. Copyright © 2017 John Wiley & Sons, Ltd.

  17. Serum paraquat concentration detected by spectrophotometry in patients with paraquat poisoning

    Science.gov (United States)

    Li, Chang-bin; Li, Xin-hua; Wang, Zhen; Jiang, Cheng-hua; Peng, Ai

    2011-01-01

    BACKGROUND: Paraquat (PQ) is a world-wide used herbicide and also a type of common poison for suicide and accidental poisoning. Numerous studies have proved that the concentration of serum PQ plays an important role in prognosis. Spectrophotometry, including common spectrophotometry and second-derivative spectrophotometry, is commonly used for PQ detection in primary hospitals. So far, lack of systematic research on the reliability of the method and the correlation between clinical features of patients with PQ poisoning and the test results has restricted the clinical use of spectrophotometry. This study aimed to evaluate the reliability and value of spectrophotometry in detecting the concentration of serum PQ. METHODS: The wavelengths for detecting the concentration of serum PQ by common and second-derivative spectrophotometry were determined. Second-derivative spectrophotometry was applied to detect the concentration of serum PQ. The linear range and precision for detection of PQ concentration by this method were confirmed. The concentration of serum PQ shown by second-derivative spectrophotometry and HPLC were compared in 8 patients with PQ poisoning. Altogether 21 patients with acute poisoning 4 hours after PQ ingestion treated in the period of October 2008 to September 2010 were retrospectively reviewed. The patients were divided into higher and lower than 1.8 μg/mL groups based on their concentrations of serum PQ measured by second-derivative spectrophotometry on admission. The severity of clinical manifestations between the two groups were analyzed with Student's t test or Fisher's exact test. RESULTS: The absorption peak of 257 nm could not be found when common spectrophotometry was used to detect the PQ concentration in serum. The calibration curve in the 0.4–8.0 μg/mL range for PQ concentration shown by second-derivative spectrophotometry obeyed Beer's law with r=0.996. The average recovery rates of PQ were within a range of 95.0% to 99.5%, relative

  18. Spectrophotometry of VV Cephei-type systems

    International Nuclear Information System (INIS)

    Piccirillo, J.

    1974-01-01

    Photoelectric spectrophotometry of four VV Cephei-type systems and two related objects is analyzed to derive the visual magnitude differences of the binary components. The results are in good agreement with previous photometric determinations. An extension of the present technique to other types of binary systems is briefly discussed. (U.S.)

  19. Process for neptunium analysis by absorption spectrophotometry

    International Nuclear Information System (INIS)

    Wagner, J.F.

    1987-01-01

    An aqueous solution of a neptunium compounds is treated by a reagent, preferentially a vanadyl sulfate oxidized by cerium IV ions, to obtain neptunium V by oxidation of neptunium IV and reduction of neptunium VI. The reagent is chosen for a negligible absorption at the wavelength used for neptunium V absorption spectrophotometry for instance 981 nm [fr

  20. Evaluation of atomic absorption Spectrophotometry (ashing, non ...

    African Journals Online (AJOL)

    Three commonly used techniques, namely atomic absorption spectrophotometry (AAS-Ashing and AAS-Non Ashing) and titrimetry (potassium permanganate titration) have been evaluated in this study to determine the calcium content in six food samples whose calcium levels ranged from 0 to more than 250mg/100g ...

  1. Simultaneous Determination of Florfenicol and Diclazuril in Compound Powder by RP-HPLC-UV Method

    Directory of Open Access Journals (Sweden)

    Leilei Guo

    2014-01-01

    Full Text Available A RP-HPLC-UV method was developed and validated for simultaneous determination of florfenicol and diclazuril in compound powder. The separation involved using a SinoChoom ODS-BP C18 (5 μm, 4.6 mm × 250 mm analytical column. The mobile phase was a mixture of acetonitrile-0.2% phosphoric acid (pH was adjusted to 3.0 with triethylamine. The ratio of acetonitrile and 0.2% phosphoric acid in the mobile phase was 60 : 40 (v/v from 0 minutes to 6 minutes and 70 : 30 (v/v from 6.1 minutes to 15 minutes. The flow rate was 1 mL/min. The temperature of the analytical column was maintained at 30°C. The detection was monitored at 225 nm and 277 nm for florfenicol and diclazuril, respectively. The excipients in the compound powder did not interfere with the drug peaks. The calibration curves of florfenicol and diclazuril were fairly linear over the concentration ranges between 50.0–500.0 μg/mL (r=0.9995 and 10.0–100.0 μg/mL (r=0.9992, respectively. The RSD of both the intraday and interday variations was below 2.1% for florfenicol and diclazuril. The method was successfully validated according to International Conference on Harmonisation and proved to be suitable for the simultaneous determination of florfenicol and diclazuril in compound powder.

  2. Preparation of flower-like CuS by solvothermal method and its photodegradation and UV protection

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Xiao-Sai; Shen, Yong, E-mail: shenyong@sues.edu.cn; Xu, Li-Hui; Wang, Li-Ming; Xing, Ya-Jun

    2016-07-25

    The flower-like CuS with hierarchical structures were synthesized by a solvothermal method. X-ray diffraction (XRD), scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectroscopy, UV–vis optical absorption spectroscopy and thermogravimetric analysis (TGA) and ultraviolet transmittance analyzer labsphere were used to characterize the as-prepared products. The results of photocatalytic degradation of Methylene blue (MB) demonstrated that the as-prepared flower-like CuS possessed high photocatalytic performance in UV and visible range and its band gap was 1.45 eV. The degradation rate of MB by CuS with the absence of H{sub 2}O{sub 2} was 98.23% and 100% under xenon lamp and Mercury tungsten blended lamp for 30 min, respectively. And a new approach for ultraviolet (UV) protection of cotton fabrics treated by flower-like CuS microspheres was innovatively investigated and the results showed that flower-like CuS was a good UV resistant material. - Highlights: • The flower-like CuS was prepared via solvothermal method. • The as-prepared CuS showed better photodegradation of MB solution under visible region. • The cotton fabric treated by the obtained flower-like CuS was proved to have a potential application in anti-UV field.

  3. UV-Visible Spectroscopic Method and Models for Assessment and Monitoring of Harmful Algal Blooms

    Science.gov (United States)

    Mitchell, B. Greg

    2000-01-01

    The development of an enhanced predictive and early warning capability for the occurrence and impact of harmful algal blooms (HABs) would be of great benefit to coastal communities. A critical issue for early detection and monitoring of HABs is the need to detect harmful algal species within a mixed-species phytoplankton assemblage. Possession of UV-absorbing compounds called mycosporine-like amino acids (MAAs) may be one factor that allows HAB species to out-compete their phytoplankton neighbors. Possession of MAAs, which we believe can be inferred from strong UV-absorption signals in phytoplankton absorption coefficients, can be used as a flag for potential HAB outbreak. The goal of this project was to develop a solar simulating UV-visible incubator to grow HAB dinoflagellates, to begin MAA analysis of samples collected on global cruises, and to carry out initial experiments on HAB dinoflagellate species in pure culture. Our scientific objectives are to quantify MAA production and spectral induction mechanisms in HAB species, to characterize spectral absorption of MAAs, and to define the ecological benefit of MAAs (i.e. photoprotection). Data collected on cruises to the global oceans will be used to parameterize phytoplankton absorption in the UV region, and this parameterization could be incorporated into existing models of seawater optical properties in the UV spectral region. Data collected in this project were used for graduate fellowship applications by Elizabeth Frame. She has been awarded an EPA STAR fellowship to continue the work initiated by this project.

  4. Ultraviolet spectrophotometry of three LINERs

    Science.gov (United States)

    Goodrich, R. W.; Keel, W. C.

    1986-01-01

    Three galaxies known to be LINERs were observed spectroscopically in the ultraviolet in an attempt to detect the presumed nonthermal continuum source thought to be the source of photoionization in the nuclei. NGC 4501 was found to be too faint for study with the IUE spectrographs, while NGC 5005 had an extended ultraviolet light profile. Comparison with the optical light profile of NGC 5005 indicates that the ultraviolet source is distributed spatially in the same manner as the optical starlight, probably indicating that the ultraviolet excess is due to a component of hot stars in the nucleus. These stars contribute detectable absorption features longward of 2500 A; together with optical data, the IUE spectra suggest a burst of star formation about 1 billion yr ago, with a lower rate continuing to produce a few OB stars. In NGC 4579, a point source contributing most of the ultraviolet excess is found that is much different than the optical light distribution. Furthermore, the ultraviolet to X-ray spectral index in NGC 4579 is 1.4, compatible with the UV to X-ray indices found for samples of Seyfert galaxies. This provides compelling evidence for the detection of the photoionizing continuum in NGC 4579 and draws the research fields of normal galaxies and active galactic nuclei closer together. The emission-line spectrum of NGC 4579 is compared with calculations from a photoionization code, CLOUDY, and several shock models. The photoionization code is found to give superior results, adding to the increasing weight of evidence that the LINER phenomenon is essentially a scaled-down version of the Seyfert phenomenon.

  5. Analysis of impurities in silver matrix by atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Hussain, R.; Ishaque, M.; Mohammad, D.

    1999-01-01

    A procedure for the analysis of aluminium, chromium, copper, lead, mercury, nickel and zinc mainly using flame lens atomic absorption spectrophotometry has been described. The results depict that the presence of silver does not introduce any significant interference, when standards are prepared in matching silver matrix solutions. The calibration curves obey the straight-line equations passing through the origin. Thus the separation of silver matrix from the analyte solutions is not necessary. The method has successfully been applied for the analysis of silver foils, wires, battery grade silver oxides and silver nitrate samples containing analyte elements in the concentration range 2 to 40 ppm. (author)

  6. Development and validation of RP-HPLC-UV/ Vis method for determination of phenolic compounds in several personal care products

    International Nuclear Information System (INIS)

    Mohammed Akkbik; Zaini Asim; Fasihuddin Ahmad

    2011-01-01

    A HPLC method with ultraviolet-visible spectrophotometry detection has been optimized and validated for the simultaneous determination of phenolic compounds, such as butylated hydroxyanisole (BHA) and butylated hydroxytoluene (BHT) as antioxidants, and octyl methyl cinnamate (OMC) as UVB-filter in several personal care products. The dynamic range was between 1 to 250 mg/ L with relative standard deviation less than 0.25 %, (n=4). Limit of detection for BHA, BHT and OMC were 0.196, 0.170 and 0.478 mg/ L, respectively. While limit of quantification for BHA, BHT and OMC were 0.593, 0.515 and 1.448 mg/ L, respectively. The recovery for BHA, BHT and OMC ranged from 92.1-105.9 %, 83.2-108.9 % and 87.3-103.7 %, respectively. The concentration ranges of BHA, BHT and OMC in 12 commercial personal care samples were 0.13-4.85, 0.16-2.30 and 0.12-65.5 mg/ g, respectively. The concentrations of phenolic compounds in these personal care samples were below than maximum allowable concentration in personal care formulation for example 0.0004 - 10 mg/ g, 0.002 - 5 mg/ g and up to 100 mg/ g for BHA, BHT and OMC, respectively. (author)

  7. Application of spectrophotometry for determination of analytes in high percentage levels

    International Nuclear Information System (INIS)

    Koteswara Rao, M.; Ram Mohan, Vijaya; Yadav, R.B.

    2009-01-01

    This paper describes the application of differential Spectrophotometry for the determination of analytes in high concentration levels unlike the conventional photometric methods that are useful for measuring concentration at trace levels. Differential spectrophotometry is based on measuring the absorbance of the test solution against a standard of accurately known concentration instead of a reagent blank or pure solvent. In this way, the error in measurement is confined to the difference in the two concentrations and is minimized. Thus the error is much smaller than in conventional Spectrophotometry, which therefore allows its application for determining analytes in major concentration. This method was applied for the assay of Niobium and Titanium used as strategic materials in various field. (author)

  8. UV-irradiation effects on polyester nuclear track detector

    International Nuclear Information System (INIS)

    Agarwal, Chhavi; Kalsi, P.C.

    2010-01-01

    The effects of UV irradiation (λ=254 nm) on polyester nuclear track detector have been investigated employing bulk-etch technique, UV-visible spectrophotometry and infra-red spectrometry (FTIR). The activation energy values for bulk-etching were found to decrease with the UV-irradiation time indicating the scission of the polymer. Not much shift in the absorption edge due to UV irradiation was seen in the UV-visible spectra. FTIR studies also indicate the scission of the chemical bonds, thereby further validating the bulk-etch rate results.

  9. Inter-laboratory comparisons of hexenuronic acid measurements in kraft eucalyptus pulps using a UV-Vis spectroscopic method

    Science.gov (United States)

    J.Y. Zhu; H.F Zhou; Chai X.S.; Donna Johannes; Richard Pope; Cristina Valls; M. Blanca Roncero

    2014-01-01

    An inter-laboratory comparison of a UV-Vis spectroscopic method (TAPPI T 282 om-13 “Hexeneuronic acid content of chemical pulp”) for hexeneuronic acid measurements was conducted using three eucalyptus kraft pulps. The pulp samples were produced in a laboratory at kappa numbers of approximately 14, 20, and 35. The hexeneuronic acid contents of the three pulps were...

  10. Acceptability criteria for linear dependence in validating UV-spectrophotometric methods of quantitative determination in forensic and toxicological analysis

    Directory of Open Access Journals (Sweden)

    L. Yu. Klimenko

    2014-08-01

    Full Text Available Introduction. This article is the result of authors’ research in the field of development of the approaches to validation of quantitative determination methods for purposes of forensic and toxicological analysis and devoted to the problem of acceptability criteria formation for validation parameter «linearity/calibration model». The aim of research. The purpose of this paper is to analyse the present approaches to acceptability estimation of the calibration model chosen for method description according to the requirements of the international guidances, to form the own approaches to acceptability estimation of the linear dependence when carrying out the validation of UV-spectrophotometric methods of quantitative determination for forensic and toxicological analysis. Materials and methods. UV-spectrophotometric method of doxylamine quantitative determination in blood. Results. The approaches to acceptability estimation of calibration models when carrying out the validation of bioanalytical methods is stated in international papers, namely «Guidance for Industry: Bioanalytical method validation» (U.S. FDA, 2001, «Standard Practices for Method Validation in Forensic Toxicology» (SWGTOX, 2012, «Guidance for the Validation of Analytical Methodology and Calibration of Equipment used for Testing of Illicit Drugs in Seized Materials and Biological Specimens» (UNODC, 2009 and «Guideline on validation of bioanalytical methods» (ЕМА, 2011 have been analysed. It has been suggested to be guided by domestic developments in the field of validation of analysis methods for medicines and, particularly, by the approaches to validation methods in the variant of the calibration curve method for forming the acceptability criteria of the obtained linear dependences when carrying out the validation of UV-spectrophotometric methods of quantitative determination for forensic and toxicological analysis. The choice of the method of calibration curve is

  11. Validation of an HPLC–UV method for the determination of digoxin residues on the surface of manufacturing equipment

    Directory of Open Access Journals (Sweden)

    ZORAN B. TODOROVIĆ

    2009-09-01

    Full Text Available In the pharmaceutical industry, an important step consists in the removal of possible drug residues from the involved equipments and areas. The cleaning procedures must be validated and methods to determine trace amounts of drugs have, therefore, to be considered with special attention. An HPLC–UV method for the determination of digoxin residues on stainless steel surfaces was developed and validated in order to control a cleaning procedure. Cotton swabs, moistened with methanol were used to remove any residues of drugs from stainless steel surfaces, and give recoveries of 85.9, 85.2 and 78.7 % for three concentration levels. The precision of the results, reported as the relative standard deviation (RSD, were below 6.3 %. The method was validated over a concentration range of 0.05–12.5 µg mL-1. Low quantities of drug residues were determined by HPLC–UV using a Symmetry C18 column (150´4.6 mm, 5 µm at 20 °C with an acetonitrile–water (28:72, v/v mobile phase at a flow rate of 1.1 mL min-1, an injection volume of 100 µL and were detected at 220 nm. A simple, selective and sensitive HPLC–UV assay for the determination of digoxin residues on stainless steel was developed, validated and applied.

  12. Spectrophotometry of the QSO NRAO 530

    International Nuclear Information System (INIS)

    Junkkarinen, V.

    1984-01-01

    Spectrophotometry of the QSO NRAO 530 with the KPNO Cryogenic Camera is reported. A redshift of 0.902 is determined from the H-beta, H-gamma, and 3727 A forbidden O II emission lines, confirming a redshift that had been based on a single line, the 2798 A Mg II. The H-beta equivalent is smaller than in normal QSOs, which may be characteristic of optically variable QSOs. 16 references

  13. Surface composition of Mercury from reflectance spectrophotometry

    Science.gov (United States)

    Vilas, Faith

    1988-01-01

    The controversies surrounding the existing spectra of Mercury are discussed together with the various implications for interpretations of Mercury's surface composition. Special attention is given to the basic procedure used for reducing reflectance spectrophotometry data, the factors that must be accounted for in the reduction of these data, and the methodology for defining the portion of the surface contributing the greatest amount of light to an individual spectrum. The application of these methodologies to Mercury's spectra is presented.

  14. Spectrophotometry of the Seyfert galaxy NGC 4593

    International Nuclear Information System (INIS)

    MacAlpine, G.M.; Williams, G.A.; Lewis, D.W.

    1979-01-01

    Spectrophotometry of the bright class 1 Seyfert galaxy NGC 4593 is presented. The emission-line characteristics are briefly discussed and compared with those of other Seyfert galaxies. The measured hydrogen Balmer-line ratios are reasonably consistent with expected recombination values, and the emission intensities of Fe II, He I 5876, and forbidden O III 4363 relative to other lines are stronger than average in NGC 4593

  15. Absolute spectrophotometry of the β Lyr

    International Nuclear Information System (INIS)

    Burnashev, V.I.; Skul'skij, M.Yu.

    1978-01-01

    In 1974 an absolute spectrophotometry of β Lyr was performed with the scanning spectrophotometer in the 3300-7400 A range. The energy distribution in the β Lyr spectrum is obtained. The β Lyr model is proposed. It is shown, that the continuous spectrum of the β Lyr radiation can be presented by the total radiation of the B8 3 and A5 3 two stars and of the gaseous envelope with Te =20000 K

  16. Objective-prism spectrophotometry of quasars

    International Nuclear Information System (INIS)

    Clowes, R.G.

    1980-01-01

    A procedure is derived for obtaining low-resolution spectrophotometry of quasars directly from the objective-prism plates on which they were discovered. Measurements with a PDS microdensitometer of approximately 130 quasar candidates in approximately the central 19 square degrees of the UK Schmidt prism plate UJ3682P were used in the application of the procedure. The success of the objective-prism spectrophotometry is demonstrated in a comparison with 12 slit spectra. Redshifts and equivalent widths can be determined with typical discrepancies of 1% and 40% respectively. This work on objective-prism spectrophotometry leads to a quantification of the selection effects that operate in the searches for emission-line objects on objective-prism plates. The quantification successfully explains an apparent discrepancy in the detection efficiencies of the CTIO-4m and Curtis Schmidt surveys for quasars. Spectra of quasars that were observed with the Image Photon Counting System on the Anglo-Australian Telescope are presented. The observations of quasars with broad absorption troughs indicate the ejection of matter with velocities up to approximately 22000kms -1 and with velocity dispersions up to approximately 11000kms -1 . Data on the wavelength dependences of the contrast γ and the grain response function g of the Kodak emulsion IIIaJ are presented. (author)

  17. Water contentwater of determination of cationic polystyrene sulfonate resins by infrared spectrophotometry

    International Nuclear Information System (INIS)

    Noki, V.

    1987-01-01

    A method of the determination of water content in polystyrene sulfonate ion-exchange resins in the presence of alkaline earth counter-ions by I.R. spectrophotometry is proposed. This method does not hold in the case of transition metal due to the formation of coordinated complexes with water molecules.

  18. Selenium determination in biological material by atomic absorption spectrophotometry in graphite furnace and using vapor generation

    International Nuclear Information System (INIS)

    Carvalho Vidal, M. de F. de.

    1984-01-01

    The applicability of the atomic absorption spectrophotometry to the determination of selenium in biological material using vapor generation and electrothermal atomization in the graphite furnace was investigated. Instrumental parameters and the analytical conditions of the methods were studied. Decomposition methods for the samples were tested, and the combustion in the Wickbold apparatus was chosen. (author) [pt

  19. Measurement of uranium concentration by molecular absorption spectrophotometry by means optical fibers

    International Nuclear Information System (INIS)

    Gauna, Alberto C.; Pascale, Ariel A.

    1996-01-01

    An on-line method for measuring the concentration of uranium in uranyl nitrate-nitric acid aqueous solutions is described. The method is based on molecular absorption spectrophotometry with transmission of light by means of optical fibers. It is ideally suited for control and processes development applications. (author)

  20. Apparatus and method for treating pollutants in a gas using hydrogen peroxide and UV light

    Science.gov (United States)

    Cooper, Charles David (Inventor); Clausen, Christian Anthony (Inventor)

    2005-01-01

    An apparatus for treating pollutants in a gas may include a source of hydrogen peroxide, and a treatment injector for creating and injecting dissociated hydrogen peroxide into the flow of gas. The treatment injector may further include an injector housing having an inlet, an outlet, and a hollow interior extending therebetween. The inlet may be connected in fluid communication with the source of hydrogen peroxide so that hydrogen peroxide flows through the hollow interior and toward the outlet. At least one ultraviolet (UV) lamp may be positioned within the hollow interior of the injector housing. The at least one UV lamp may dissociate the hydrogen peroxide flowing through the tube. The dissociated hydrogen peroxide may be injected into the flow of gas from the outlet for treating pollutants, such as nitrogen oxides.

  1. Validation of HPLC method for the simultaneous and quantitative determination of 12 UV-filters in cosmetics.

    Science.gov (United States)

    Nyeborg, M; Pissavini, M; Lemasson, Y; Doucet, O

    2010-02-01

    The aim of the study was the validation of a high-performance liquid chromatography (HPLC) method for the simultaneous and quantitative determination of twelve commonly used organic UV-filters (phenylbenzimidazole sulfonic acid, benzophenone-3, isoamyl p-methoxycinnamate, diethylamino hydroxybenzoyl hexyl benzoate, octocrylene, ethylhexyl methoxycinnamate, ethylhexyl salicylate, butyl methoxydibenzoylmethane, diethylhexyl butamido triazone, ethylhexyl triazone, methylene bis-benzotriazolyl tetramethylbutylphenol and bis-ethylhexyloxyphenol methoxyphenyl triazine) contained in suncare products. The separation and quantitative determination was performed in <30 min, using a Symmetry Shield(R) C18 (5 microm) column from Waters and a mobile phase (gradient mode) consisting of ethanol and acidified water. UV measurements were carried out at multi-wavelengths, according to the absorption of the analytes.

  2. Desenvolvimento e validação de um método analítico por espectrofotometria UV para quantificação de carvedilol

    Directory of Open Access Journals (Sweden)

    Paola Aline Amarante Borba

    2013-01-01

    Full Text Available This paper reports the development and validation of a new analytical method using UV spectrophotometry to quantify carvedilol (CRV in hydrophilic matrices and raw material. This method was shown to be linear, accurate, precise, robust and to have adequate limits of quantification and detection (LQ and LD, respectively, allowing its use in the dissolution test of hydrophilic matrices. The content of CRV determined through this method was compared with two previously validated methods based on the reference techniques of High Performance Liquid Chromatography (HPLC and Potentiometric Titrations (PT. ANOVA confirmed the equivalence of these methods, showing no significant differences.

  3. Effect of fungal mycelia on the HPLC-UV and UV-vis spectrophotometric assessment of mycelium-bound epoxide hydrolase using glycidyl phenyl ether.

    Science.gov (United States)

    Dolcet, Marta M; Torres, Mercè; Canela, Ramon

    2016-06-25

    The use of mycelia as biocatalysts has technical and economic advantages. However, there are several difficulties in obtaining accurate results in mycelium-catalysed reactions. Firstly, sample extraction, indispensable because of the presence of mycelia, can bring into the extract components with a similar structure to that of the analyte of interest; secondly, mycelia can influence the recovery of the analyte. We prepared calibration standards of 3-phenoxy-1,2-propanediol (PPD) in the pure solvent and in the presence of mycelia (spiked before or after extraction) from five fungi (Aspergillus niger, Aspergillus tubingensis, Penicillium aurantiogriseum, Penicillium sp. and Aspergillus terreus). The quantification of PPD was carried out by HPLC-UV and UV-vis spectrophotometry. The manuscript shows that the last method is as accurate as the HPLC method. However, the colorimetric method led to a higher data throughput, which allowed the study of more samples in a shorter time. Matrix effects were evaluated visually from the plotted calibration data and statistically by simultaneously comparing the intercept and slope of calibration curves performed with solvent, post-extraction spiked standards and pre-extraction spiked standards. Significant differences were found between the post- and pre-extraction spiked matrix-matched functions. Pre-extraction spiked matrix-matched functions based on A. tubingensis mycelia, selected as the reference, were validated and used to compensate for low recoveries. These validated functions were successfully applied to the quantification of PPD achieved during the hydrolysis of glycidyl phenyl ether by mycelium-bound epoxide hydrolases and equivalent hydrolysis yields were determined by HPLC-UV and UV-vis spectrophotometry. This study may serve as starting point to implement matrix effects evaluation when mycelium-bound epoxide hydrolases are studied. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. ANALISA FLAVONOID DARI EKSTRAK ETANOL 96% KULIT BUAH OKRA MERAH (Abelmoschus esculentus L. Moench SECARA KROMATOGRAFI LAPIS TIPIS DAN SPEKTROFOTOMETRI UV-VIS

    Directory of Open Access Journals (Sweden)

    Nia Lisnawati

    2016-03-01

    Full Text Available Has done research on flavonoids Analysis of Ethanol Extract 96% Fruit Leather Red Okra In Thin Layer Chromatography and Spectrophotometer UV-Vis. The purpose of this study was to analyze the content of the fruit skin red okra (Abelmoschus esculentus L. Moench by using the method of thin layer chromatography (TLC under UV light and spectrophotometry UV-Vis. Reference standards used in this study is the Standard Solution Routine Quercetin. The results of the research that has been done by the method of thin layer chromatography obtained Rf values of 0.81 and produces the color orange. And the results of research conducted by spectrophotometry UV-Vis method obtained 333,117 mg.L-1 or 421,629 mg.kg-1 or 0,84339 %. The conclusion from this study is that the 96% ethanol extract of the fruit leather red okra (Abelmoschus esculentus L. Moench positive (+ contains flavonoids with levels of 0,84339 %.

  5. A conformational study of protonated noradrenaline by UV-UV and IR dip double resonance laser spectroscopy combined with an electrospray and a cold ion trap method.

    Science.gov (United States)

    Wako, Hiromichi; Ishiuchi, Shun-Ichi; Kato, Daichi; Féraud, Géraldine; Dedonder-Lardeux, Claude; Jouvet, Christophe; Fujii, Masaaki

    2017-05-03

    The conformer-selected ultraviolet (UV) and infrared (IR) spectra of protonated noradrenaline were measured using an electrospray/cryogenic ion trap technique combined with photo-dissociation spectroscopy. By comparing the UV photo dissociation (UVPD) spectra with the UV-UV hole burning (HB) spectra, it was found that five conformers coexist under ultra-cold conditions. Based on the spectral features of the IR dip spectra of each conformer, two different conformations on the amine side chain were identified. Three conformers (group I) were assigned to folded and others (group II) to extended structures by comparing the observed IR spectra with the calculated ones. Observation of the significantly less-stable extended conformers strongly suggests that the extended structures are dominant in solution and are detected in the gas phase by kinetic trapping. The conformers in each group are assignable to rotamers of OH orientations in the catechol ring. By comparing the UV-UV HB spectra and the calculated Franck-Condon spectra obtained by harmonic vibrational analysis of the S 1 state, with the aid of relative stabilization energies of each conformer in the S 0 state, the absolute orientations of catechol OHs of the observed five conformers were successfully determined. It was found that the 0-0 transition of one folded conformer is red-shifted by about 1000 cm -1 from the others. The significant red-shift was explained by a large contribution of the πσ* state to S 1 in the conformer in which an oxygen atom of the meta-OH group is close to the ammonium group.

  6. UV-vis in situ spectrometry data mining through linear and non linear analysis methods

    Directory of Open Access Journals (Sweden)

    Liliana López-Kleine

    2014-01-01

    Full Text Available Los espectrómetros UV-visibles son captores que registran la absorbancia de luz emitida por partículas suspendidas en el agua a diferentes longitudes de onda y proporcionan mediciones en continuo, las cuales pueden ser interpretadas como concentraciones de parámetros comúnmente usados para evaluar el estado físico-químico de cuerpos de agua. Parámetros clásicos usados para detectar la presencia de contaminación en el agua son los sólidos suspendidos totales (TSS y la demanda química de oxígeno (CDO. Métodos de análisis flexibles y eficientes son necesarios para extraer información útil para fines de gestión y monitoreo a partir de los datos multivariados que proporcionan los captores. Se han usado métodos de calibración de tipo regresión parcial por mínimos cuadrados parciales (PLS. Varios autores han demostrado la necesidad de realizar la calibración para cada tipo de datos y cada cuerpo de agua, así como explorar métodos de análisis lineales y no lineales para el análisis de datos UV-visible y para determinar su relación con parámetros clásicos. En este trabajo se aplican métodos de análisis multivariado lineales y no lineales para la minería de datos UV-vis de alta dimensión, los cuales resultan útiles para la identificación de relaciones entre parámetros y longitudes de onda, la detección de muestras atípicas, así como la detección de estructuras no lineales en los datos.

  7. UV-vis in situ spectrometry data mining through linear and non linear analysis methods

    OpenAIRE

    Liliana López-Kleine; Andrés Torres

    2014-01-01

    Los espectrómetros UV-visibles son captores que registran la absorbancia de luz emitida por partículas suspendidas en el agua a diferentes longitudes de onda y proporcionan mediciones en continuo, las cuales pueden ser interpretadas como concentraciones de parámetros comúnmente usados para evaluar el estado físico-químico de cuerpos de agua. Parámetros clásicos usados para detectar la presencia de contaminación en el agua son los sólidos suspendidos totales (TSS) y la demanda química de oxíge...

  8. A Facile, Nonreactive Hydrogen Peroxide (H2O2) Detection Method Enabled by Ion Chromatography with UV Detector.

    Science.gov (United States)

    Song, Mingrui; Wang, Junli; Chen, Baiyang; Wang, Lei

    2017-11-07

    Hydrogen peroxide (H 2 O 2 ) is ubiquitous in the natural environment, and it is now widely used for pollutant control in water and wastewater treatment processes. However, current analytical methods for H 2 O 2 inevitably require reactions between H 2 O 2 and other reactants to yield signals and are thus likely subjective to the interferences of coexisting colored, oxidative, and reductive compounds. In order to overcome these barriers, we herein for the first time propose to analyze H 2 O 2 by ion chromatography (IC) using an ultraviolet (UV) detector. The proposal is based on two principles: first, that H 2 O 2 can deprotonate to hydroperoxyl ion (HO 2 - ) when eluent pH is higher than the acid-dissociation coefficient of H 2 O 2 (pK a = 11.6); and second, that after separation from other compounds via IC column, H 2 O 2 can be quantified by a UV detector. Under favorable operating conditions, this method has successfully achieved acceptable recoveries (>91%) of H 2 O 2 dosed to ultrapure and natural waters, a calibration curve with R 2 > 0.99 for a wide range of H 2 O 2 concentrations from 0.1 to 50 mg/L and a method detection limit of 0.027 mg/L. In addition, this approach was shown to be capable of distinguishing H 2 O 2 from anions (e.g., fluoride and chloride) and organics (e.g., glycolate) and monochloramine, suggesting that it is insensitive to many neighboring compounds as long as they do not react quickly with H 2 O 2 . Hence, this study proves the combination of IC and UV detector a facile and reliable method for H 2 O 2 measurement.

  9. Determination of Lead in Blood by Atomic Absorption Spectrophotometry1

    Science.gov (United States)

    Selander, Stig; Cramér, Kim

    1968-01-01

    Lead in blood was determined by atomic absorption spectrophotometry, using a wet ashing procedure and a procedure in which the proteins were precipitated with trichloroacetic acid. In both methods the lead was extracted into isobutylmethylketone before measurement, using ammonium pyrrolidine dithiocarbamate as chelator. The simpler precipitation procedure was shown to give results identical with those obtained with the ashing technique. In addition, blood specimens were examined by the precipitation method and by spectral analysis, which method includes wet ashing of the samples, with good agreement. All analyses were done on blood samples from `normal' persons or from lead-exposed workers, and no additions of inorganic lead were made. The relatively simple protein precipitation technique gave accurate results and is suitable for the large-scale control of lead-exposed workers. PMID:5663425

  10. Studies of selected transuranium and lanthanide tri-iodides under pressure using absorption spectrophotometry

    International Nuclear Information System (INIS)

    Haire, R.G.; Young, J.P.; Peterson, J.R.; Tennessee Univ., Knoxville; Benedict, U.

    1987-01-01

    The anhydrous tri-iodides of plutonium, americium and curium under pressure have been investigated using absorption spectrophotometry. These initial studies on plutonium and curium tri-iodides together with the published data for americium tri-iodide show that the rhombohedral form of these compounds (BiI 3 -type structure) can be converted to the orthorhombic form (PuBr 3 -type structure) by applying pressure at room temperature. Absorption spectrophotometry can often differentiate between two crystallographic forms of a material and has been used in the present high-pressure studies to monitor the effects of pressure on the tri-iodides. A complication in these studies of the tri-iodides is a significant shift of their absorption edges with pressure from the near UV to the visible spectral region. With curium tri-iodide this shift causes interference with the major f-f absorption peaks and precludes identification by absorption spectrophotometry of the high pressure phase of CmI 3 . (orig.)

  11. Practical application of solid phase spectrophotometry in analysis of materials and goods of mining and metallurgy

    International Nuclear Information System (INIS)

    Duan Qunzhang

    1999-01-01

    The author reviewed recent development and practical application of solid phase spectrophotometry in analysis of materials and goods of mining-metallurgy. Separation and preconcentration and conditions of coloring determination, sensitivity and range of detection, as well as interference of corresponding method are discussed

  12. An application of micelle solubilization spectrophotometry in the determination of thorium

    International Nuclear Information System (INIS)

    Peng Changhai; Zeng Xiaoming

    1988-01-01

    In this review article the characteristics of the analytical method of Th by means of micelle solubilization spectrophotometry are described and the mechanism of the solubilization and chemical reactions involved is discussed. Also the various color-developing reagents that have been used for this determination are described and compared

  13. A laboratory manual for the determination of metals in water and wastewater by atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Smith, R.

    1983-01-01

    This guide presents, in addition to a brief discussion of the basic principles and practical aspects of atomic absorption spectrophotometry, a scheme of analysis for the determination of 19 metals in water and wastewater, 16 by flame atomic absorption and 3 by vapour generation techniques. Simplicity, speed and accuracy were the main criteria considered in the selection of the various methods

  14. UvA Rescue Technical Report: a description of the methods and algorithms implemented in the UvA Rescue code release

    NARCIS (Netherlands)

    Visser, A.

    2012-01-01

    This technical report gives the background documentation behind the competition code of the UvA Rescue Team, who participates in the RoboCup Simulation League. The described code is used in the Virtual Robot competition, where a team of robots, guided by a single operator, has to find as many

  15. An HPLC-UV method for the measurement of permeability of marker drugs in the Caco-2 cell assay

    Directory of Open Access Journals (Sweden)

    J.M. Kratz

    2011-06-01

    Full Text Available The Caco-2 cell line has been used as a model to predict the in vitro permeability of the human intestinal barrier. The predictive potential of the assay relies on an appropriate in-house validation of the method. The objective of the present study was to develop a single HPLC-UV method for the identification and quantitation of marker drugs and to determine the suitability of the Caco-2 cell permeability assay. A simple chromatographic method was developed for the simultaneous determination of both passively (propranolol, carbamazepine, acyclovir, and hydrochlorothiazide and actively transported drugs (vinblastine and verapamil. Separation was achieved on a C18 column with step-gradient elution (acetonitrile and aqueous solution of ammonium acetate, pH 3.0 at a flow rate of 1.0 mL/min and UV detection at 275 nm during the total run time of 35 min. The method was validated and found to be specific, linear, precise, and accurate. This chromatographic system can be readily used on a routine basis and its utilization can be extended to other permeability models. The results obtained in the Caco-2 bi-directional transport experiments confirmed the validity of the assay, given that high and low permeability profiles were identified, and P-glycoprotein functionality was established.

  16. Tunable Diode Laser Heterodyne Spectrophotometry of Ozone

    Science.gov (United States)

    Fogal, P. F.; McElroy, C. T.; Goldman, A.; Murcray, D. G.

    1988-01-01

    Tunable diode laser heterodyne spectrophotometry (TDLHS) has been used to make extremely high resolution (less than 0.0005/ cm) solar spectra in the 9.6 micron ozone band. Observations have shown that a signal-to-noise ratio of 95 : 1 (35% of theoretical) for an integration time of 1/8 second can be achieved at a resolution of 0.0005 wavenumbers. The spectral data have been inverted to yield a total column amount of ozone, in good agreement with that. measured at the nearby National Oceanographic and Atmospheric Administration (NOAA) ozone monitoring facility in Boulder, Colorado.

  17. A validated HPLC-UV method for the analysis of galloylquinic acid derivatives and flavonoids in Copaifera langsdorffii leaves.

    Science.gov (United States)

    Motta, Erick Vicente da Silva; da Costa, Juliana de Carvalho; Bastos, Jairo Kenupp

    2017-09-01

    Copaifera langsdorffii Desf. (Fabaceae, Caesalpinioideae), popularly known as "copaiba" or "pau d'óleo", is a species of tree that is found throughout Brazil. The leaves of this tree are used in folk medicine to treat kidney stones. Galloylquinic acid derivatives and flavonoids are the main secondary metabolites found in C. langsdorffii leaves and are likely to be responsible for the effectiveness of this treatment. As an attempt to produce a phytotherapic, we have developed a reliable HPLC-UV method for the quality control of C. langsdorffii leaves. Phenolic compounds were extracted from C. langsdorffii leaves using 70% aqueous ethanol as the extraction solvent. HPLC-UV analyses were carried out on a Synergi Polar-RP column (100×3.0mm, 2.5μm), and the mobile phase was made up of formic acid-water (0.1:99.9, solvent A), and isopropanol-methanol-acetonitrile (5:40:60, solvent B). The elution gradient was A:B (90:10 to 85:15) in 8.0min, followed by A:B (85:15 to 64:36) up to 30.0min, using a flow rate of 0.7mL/min, and UV detection at 280nm. This method was used to quantify nine galloylquinic acid derivatives and two flavonoids, which gave a good detection response and linearity in the range of 1.88-110.0μg/mL. Furthermore, the detection and quantification limits ranged from 0.070 to 0.752μg/mL, and 0.211-2.278μg/mL respectively, with a maximum RSD of 4.18%. The method is reliable for the quality control of C. langsdorffii raw material, its hydroethanolic extract, and could potentially be used to quantify these compounds in other Copaifera species. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Analytical method for the determination of cyromazine and melamine residues in soil using LC-UV and GC-MSD.

    Science.gov (United States)

    Yokley, R A; Mayer, L C; Rezaaiyan, R; Manuli, M E; Cheung, M W

    2000-08-01

    A method is reported for the determination of cyromazine and melamine residues in soil. Soil samples are extracted twice via mechanical shaking, each time with 70% acetonitrile/30% 0.050 M ammomium carbonate for 30 min. An aliquot portion of the pooled extracts is subjected to strong cation exchange (SCX) purification on AG 50W-X4 resin. Final analysis is accomplished using liquid chromatography-ultraviolet (LC-UV) detection at a wavelength of 214 nm. Confirmatory analyses can be performed using gas chromatography-mass selective detection (GC-MSD) in the selected ion monitoring (SIM) mode. The limit of detection (LOD) is 2.5 ng injected and the limit of quantification (LOQ) is 10 ppb when using LC-UV for the analysis of N-cyclopropyl-1,3,5-triazine-2,4, 6-triamine (cyromazine) and 1,3,5-triazine-2,4,6-triamine (melamine). The LOD is 0.050 ng injected and the LOQ is 10 ppb when using GC-MSD for confirmatory analyses. The mean procedural recoveries were 97 and 95% and the standard deviations were 16 and 11% for cyromazine and melamine, respectively (n = 24), when using LC-UV. The mean procedural recoveries were 107 and 92% and the standard deviations were 9.9 and 16% for cyromazine and melamine, respectively (n = 29), when using GC-MSD. The method validation study was conducted under U.S. EPA FIFRA Good Laboratory Practice Guidelines 40 CFR 160. The method also passed an Independent Laboratory Validation (ILV) as per U.S. EPA FIFRA Subdivision N.

  19. Knowledge of outdoor workers on the effects of natural UV radiation and methods of protection against exposure.

    Science.gov (United States)

    Hault, K; Rönsch, H; Beissert, S; Knuschke, P; Bauer, A

    2016-04-01

    The most important but influenceable risk factor in the development of skin cancer is the unprotected exposure to solar ultraviolet (UV) radiation. In order to assure adequate and effective protection against UV exposure, a level of knowledge about solar radiation and its effects is required. The objective of this study was to assess the knowledge of workers in outdoor professions on the effects of natural UV radiation and methods of protection against exposure. Forty outdoor workers were given a standardized questionnaire designed to ascertain their level of knowledge. The majority of participants knew exposure to solar radiation can be detrimental depending on exposure time. Eighty-three percentage recognized that people working regularly in an outdoor environment may be at risk due to high exposure. Long-sleeved clothing plus headgear and sunscreen containing sun-protecting substances were deemed adequate methods of protection by 83% and 85% respectively. Seventy percentage of the outdoor workers were familiar with the definition of the sun protection factor (SPF), yet only 25% correctly identified the amount of sunscreen needed to achieve the SPF as indicated on the product. A mere 8% of participants knew that symptoms of a sunburn first became apparent 3 h after sun exposure and only 18% were able to accurately gauge the amount of time they could spend in the sun before developing one. Although 30% had heard of the ultraviolet index (UVI), only 13% understood that protecting your skin using additional measures is recommended as of UVI 3. Overall, 30% of the outdoor workers thought themselves sufficiently protected against the harmful effects of the sun. While the participants of this study had a basic fundamental understanding of the effects of solar radiation and methods of protection against exposure, there remains an urgent need for further clarification across all demographic groups. © 2016 European Academy of Dermatology and Venereology.

  20. Effects of UV assistance on the properties of al-doped ZnO thin films deposited by sol-gel method

    Science.gov (United States)

    Tseng, Yung-Kuan; Pai, Feng-Ming; Chen, Yan-Cheng; Wu, Chao-Hsien

    2013-11-01

    We report here the preparation of aluminum doped zinc oxide transparent conductive thin films by a UV-assisted sol-gel method. It was found that UV irradiation creates ozone, which promotes the conductivity and transparency of the films. Boro-silicate glasses are used as substrates; an PGME is used as a solvent; after spin-coating, the films are dried and radiated with UV and then heated to 400°C for decarburization and 500°C for annealing under air. The surface morphologies of the prepared films are observed by FE-SEM and AFM. It was found that the films irradiated with UV-C are smoother and denser. An XRD analysis shows that the films have a typical wurtzite crystalline structure with a c-axis orientation normal to the surface. The electric resistance values measured with a four-point probe show that the films irradiated with UV have better conductivity (at approximately 3.4 × 10-3Ω-cm) than the films that did not undergo UV irradiation. An analysis by visible light spectrometry indicates that the AZO films irradiated with UV are more transparent than the films without UV-irradiation.

  1. An analytical method for determination of fullerenes and functionalized fullerenes in soils with high performance liquid chromatography and UV detection

    International Nuclear Information System (INIS)

    Carboni, Andrea; Emke, Erik; Parsons, John R.; Kalbitz, Karsten; Voogt, Pim de

    2014-01-01

    Graphical abstract: -- Highlights: •A total of eight fullerenes can be analyzed in a single run with HPLC-UV. •The method allows the analysis of fullerenes in soil at relatively low concentrations. •The method developed is robust, highly reproducible and relatively efficient. •The method can be applied to the study of the environmental fate and toxicology of fullerenes. -- Abstract: Fullerenes are carbon-based nanomaterials expected to play a major role in emerging nanotechnology and produced at an increasing rate for industrial and household applications. In the last decade a number of novel compounds (i.e. fullerene derivatives) is being introduced into the market and specific analytical methods are needed for analytical purposes as well as environmental and safety issues. In the present work eight fullerenes (C60 and C70) and functionalized fullerenes (C60 and C70 exohedral-derivatives) were selected and a novel liquid chromatographic method was developed for their analysis with UV absorption as a method of detection. The resulting HPLC-UV method is the first one suitable for the analysis of all eight compounds. This method was applied for the analysis of fullerenes added to clayish, sandy and loess top-soils at concentrations of 20, 10 and 5 μg kg −1 and extracted with a combination of sonication and shaking extraction. The analytical method limits of detection (LoD) and limits of quantification (LoQ) were in the range of 6–10 μg L −1 and 15–24 μg L −1 respectively for the analytical solutions. The extraction from soil was highly reproducible with recoveries ranging from 47 ± 5 to 71 ± 4% whereas LoD and LoQ for all soils tested were of 3 μg kg −1 and 10 μg kg −1 respectively. No significant difference in the extraction performance was observed depending of the different soil matrices and between the different concentrations. The developed method can be applied for the study of the fate and toxicity of fullerenes in complex matrices

  2. Determination of astaxanthin in Haematococcus pluvialis by first-order derivative spectrophotometry.

    Science.gov (United States)

    Liu, Xiao Juan; Juan, Liu Xiao; Wu, Ying Hua; Hua, Wu Ying; Zhao, Li Chao; Chao, Zhao Li; Xiao, Su Yao; Yao, Xiao Su; Zhou, Ai Mei; Mei, Zhou Ai; Liu, Xin; Xin, Liu

    2011-01-01

    A highly selective, convenient, and precise method, first-order derivative spectrophotometry, was applied for the determination of astaxanthin in Haematococcus pluvialis. Ethyl acetate and ethanol (1:1, v/v) were found to be the best extraction solvent tested due to their high efficiency and low toxicity compared with nine other organic solvents. Astaxanthin coexisting with chlorophyll and beta-carotene was analyzed by first-order derivative spectrophotometry in order to optimize the conditions for the determination of astaxanthin. The results show that when detected at 432 nm, the interfering substances could be eliminated. The dynamic linear range was 2.0-8.0 microg/mL, with a correlation coefficient of 0.9916. The detection threshold was 0.41 microg/mL. The RSD for the determination of astaxanthin was in the range of 0.01-0.06%; the results of recovery test were 98.1-108.0%. The statistical analysis between first-order derivative spectrophotometry and HPLC by T-testing did not exceed their critical values, revealing no significant differences between these two methods. It was proved that first-order derivative spectrophotometry is a rapid and convenient method for the determination of astaxanthin in H. pluvialis that can eliminate the negative effect resulting from the coexistence of astaxanthin with chlorophyll and beta-carotene.

  3. Ensaio de dissolução de cápsulas de fluconazol: problemas encontrados na determinação por espectrofotometria na região do UV

    Directory of Open Access Journals (Sweden)

    D.M. Oliveira

    2010-11-01

    Full Text Available

    Entre as classes terapêuticas analisadas no Programa Nacional de Verificação da Qualidade de Medicamentos (PROVEME, o antifúngico fluconazol constava na apresentação de cápsulas de diferentes procedências. Na realização dos ensaios de dissolução conforme as técnicas dos fabricantes, constatou-se que os valores obtidos por espectrofotometria-UV foram superiores aos obtidos nos ensaios de teor e uniformidade de conteúdo, cuja determinação foi por CLAE-UV. Considerando este fato, foi objetivo deste trabalho realizar o ensaio de dissolução destas amostras pelos respectivos métodos dos fabricantes e o quantitativo do ensaio por espectrofotometria no UV e por CLAE-UV, a fim de avaliar as possíveis interferências dos excipientes nestas determinações. Os valores obtidos por espectrofotometria foram superiores aos obtidos por CLAE, confirmando a interferência dos excipientes. Concluiu-se que a metodologia a ser empregada na análise de fármacos deve ser criteriosamente selecionada, a fim de evitar resultados não condizentes com a real formulação do produto. Palavras-chave: cápsulas de fluconazol, CLAE, dissolução, espectrofotometria. ABSTRACT Among the therapeutic classes analyzed in the Programa Nacional de Verificação da Qualidade de Medicamentos (PROVEME consisted the antifungal fluconazole in the dosage form of capsules from different origins. In dissolution tests, according to manufacturers techniques, it was found that the values obtained by UV-spectrophotometry were higher than those obtained from tests of content and content uniformity, whose determination was by HPLC-UV. Considering this fact, the objective of this study was to perform the dissolution test of these samples by the respective manufacturers methods and the quantitative assay by UV-spectrophotometry and HPLC-UV, to evaluate possible interferences of excipients in these determinations. The values obtained by spectrophotometry were

  4. Development and Validation of UV Spectrophotometric Method For Determination of Bisoprolol Fumarate in Bulk and Pharmaceutical Dosage Forms

    Directory of Open Access Journals (Sweden)

    Shahinaz Mohammed

    2017-10-01

    Full Text Available In this study a simple, accurate and precise UV- spectrophotometric method was developed for the estimation of bisoprolol fumarate (BF in bulk and tablet dosage form. The method was based on measurement of absorbance of BF aqueous solution at 225 nm. Validation was conducted in accordance to ICH guidelines. The calibration curve was linear in the concentration range 5.0-30.0 µg/mL with correlation coefficient not less than 0.996. The limit of detection and limit of quantification were 0.22 μg/ml and 0.66 μg/ml, respectively. Intraday and intermediate precision of the developed method were reflected by the low RSD% values (1.19 and 0.854, respectively. The recovery percentage was 100.6 ± 0.6%, n=3. The proposed method was applied for the assay of BF in three different brands.

  5. A novel method to prepare superhydrophobic, UV resistance and anti-corrosion steel surface

    KAUST Repository

    Isimjan, Tayirjan T.

    2012-11-01

    Both TiO 2 and SiO 2 coated steel surfaces containing micro- and nanoscale binary structures with different surface roughness were successfully fabricated by means of a facile layer by layer deposition process followed by heat treatment. The resulting surfaces were modified by the low free energy chemical PTES (1H,1H,2H,2H-Perfluorodecyltriethoxysilane). The experimental results of wettability exhibit that such modified surfaces have a strong repulsive force to water droplets, their static contact angles exceed 165°, receding angle>160°, advanced angles>170° and slide angle<1°. The resulting surfaces not only exhibit superhydrophobic properties but also show strong UV resistance (after coating SiO 2 on top of TiO 2) and strong stability to various solvents including 0.01% HCl solution. © 2012 Elsevier B.V.

  6. Quantitation of heparosan with heparin lyase III and spectrophotometry.

    Science.gov (United States)

    Huang, Haichan; Zhao, Yingying; Lv, Shencong; Zhong, Weihong; Zhang, Fuming; Linhardt, Robert J

    2014-02-15

    Heparosan is Escherichia coli K5 capsule polysaccharide, which is the key precursor for preparing bioengineered heparin. A rapid and effective quantitative method for detecting heparosan is important in the large-scale production of heparosan. Heparin lyase III (Hep III) effectively catalyzes the heparosan depolymerization, forming unsaturated disaccharides that are measurable using a spectrophotometer at 232 nm. We report a new method for the quantitative detection of heparosan with heparin lyase III and spectrophotometry that is safer and more specific than the traditional carbazole assay. In an optimized detection system, heparosan at a minimum concentration of 0.60 g/L in fermentation broth can be detected. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Development and validation of a FIA/UV-vis method for pK(a) determination of oxime based acetylcholinesterase reactivators.

    Science.gov (United States)

    Musil, Karel; Florianova, Veronika; Bucek, Pavel; Dohnal, Vlastimil; Kuca, Kamil; Musilek, Kamil

    2016-01-05

    Acetylcholinesterase reactivators (oximes) are compounds used for antidotal treatment in case of organophosphorus poisoning. The dissociation constants (pK(a1)) of ten standard or promising acetylcholinesterase reactivators were determined by ultraviolet absorption spectrometry. Two methods of spectra measurement (UV-vis spectrometry, FIA/UV-vis) were applied and compared. The soft and hard models for calculation of pK(a1) values were performed. The pK(a1) values were recommended in the range 7.00-8.35, where at least 10% of oximate anion is available for organophosphate reactivation. All tested oximes were found to have pK(a1) in this range. The FIA/UV-vis method provided rapid sample throughput, low sample consumption, high sensitivity and precision compared to standard UV-vis method. The hard calculation model was proposed as more accurate for pK(a1) calculation. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Real-time dissolution behavior of furosemide in biorelevant media as determined by UV imaging

    DEFF Research Database (Denmark)

    Gordon, Sarah; Naelapää, Kaisa; Rantanen, Jukka

    2013-01-01

    M bile salt/phospholipid, pH 6.5) together with corresponding blank buffer were employed. Dissolution rates as a function of flow rate (0.2-1.0 mL/min) were determined directly from UV images, and by analysis of collected effluent using UV spectrophotometry. A good agreement in dissolution rates...

  9. Effect of UV irradiation on Cu2ZnSnS4 thin films prepared by the sol–gel sulfurization method

    International Nuclear Information System (INIS)

    Miyazawa, Hayato; Tanaka, Kunihiko; Uchiki, Hisao

    2015-01-01

    Cu 2 ZnSnS 4 (CZTS) thin films were fabricated on Mo-coated soda lime glass substrates by the sol–gel sulfurization method, which is a non-vacuum process. UV irradiation was introduced to the drying process, resulting in a significant increase in the grain size and density as well as a remarkable improvement in the crystallinity of the CZTS films. In addition, sulfurization of the Mo substrate was suppressed due to the increased density. We confirmed that the carbon/metal ratio in the precursor increased as a result of the UV irradiation. - Graphical abstract: Surface and cross sectional SEM images of the (a) CZTS prepared without UV irradiation and (b) CZTS prepared with UV irradiation. - Highlights: • CZTS thin film was prepared by sol–gel sulfurization method. • UV irradiation was introduced during the drying process. • Density and crystallinity of the CZTS films were improved by the UV irradiation. • Sulfurization of Mo substrates was suppressed by the UV irradiation.

  10. Micro-lightguide spectrophotometry for tissue perfusion in ischemic limbs

    DEFF Research Database (Denmark)

    Jørgensen, Lise Pyndt; Schroeder, Torben V

    2012-01-01

    To validate micro-lightguide spectrophotometry (O2C) in patients with lower limb ischemia and to compare results with those obtained from toe blood pressure.......To validate micro-lightguide spectrophotometry (O2C) in patients with lower limb ischemia and to compare results with those obtained from toe blood pressure....

  11. UV-vis spectra as an alternative to the Lowry method for quantify hair damage induced by surfactants.

    Science.gov (United States)

    Pires-Oliveira, Rafael; Joekes, Inés

    2014-11-01

    It is well known that long term use of shampoo causes damage to human hair. Although the Lowry method has been widely used to quantify hair damage, it is unsuitable to determine this in the presence of some surfactants and there is no other method proposed in literature. In this work, a different method is used to investigate and compare the hair damage induced by four types of surfactants (including three commercial-grade surfactants) and water. Hair samples were immersed in aqueous solution of surfactants under conditions that resemble a shower (38 °C, constant shaking). These solutions become colored with time of contact with hair and its UV-vis spectra were recorded. For comparison, the amount of extracted proteins from hair by sodium dodecyl sulfate (SDS) and by water were estimated by the Lowry method. Additionally, non-pigmented vs. pigmented hair and also sepia melanin were used to understand the washing solution color and their spectra. The results presented herein show that hair degradation is mostly caused by the extraction of proteins, cuticle fragments and melanin granules from hair fiber. It was found that the intensity of solution color varies with the charge density of the surfactants. Furthermore, the intensity of solution color can be correlated to the amount of proteins quantified by the Lowry method as well as to the degree of hair damage. UV-vis spectrum of hair washing solutions is a simple and straightforward method to quantify and compare hair damages induced by different commercial surfactants. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Design of simple UV Spectrophotometric and HPLC methods for assay of artesunate and amodiaquine in fixed dose tablet formulations

    International Nuclear Information System (INIS)

    Ashie, Agatha Dei

    2013-07-01

    Artesunate and Amodiaquine combination is one of the first line drugs for the treatment of uncomplicated malaria. To prevent treatment failures and emergence of resistant strains of the Plasmodium parasite, patients are entreated to comply with treatment regimens. Thus fixed dose tablet formulations came as a relieve to patients, ensuring proper compliance as the number of tablets to be taken was reduced. It is therefore important to develop simple methods of assay for these formulations to ensure that quality drugs are available and to prevent resistance to these drugs. This thesis describes Ultraviolet (UV) and High Performance Liquid Chromatographic (HPLC) methods of assay for Artesunate (AS) and Amodiaduine Hydrochloride (AMQ) in fixed dose tablet formulations. The UV absorption spectroscopy was used to establish a wavelength of maximum absorption and the Beer’s plot generated. At 339nm, Amodiaquine Hydrochloride was assayed accurately in methanol with a high r"2 value of 0.998, an intra and inter day precision of Relative Standard Deviation (RSD) of 1.52% and 1.86% respectively. The Beer’s plot was obeyed in a concentration range of 3.5 - 24.8(µg/mL). The limit of detection and limit of quantification was 1.23(µg/mL) and 3.73(µg/mL) respectively. However the UV method could not be used to assay AS simultaneously with AMQ. A mobile phase of 60% acetonitrile and 40% of 0.05% trifluoroacetic acid, flow rate of 1ml/min, wavelength of detection of 225nm and a C_1_8 stationary phase are the parameters for the HPLC method. The r"2 for the HPLC method was 0.996 and 0.995 for Amodiaquine hydrochloride and Artesunate respectively. The intra and inter day precision were 1.07% and 1.42% respectively. The limit of detection and limit of quantification were 0.015%w/v and 0.0465%w/v for Amodiaquine hydrochloride and 0.054%w/v and 0.019%w/v for Artesunate respectively. The concentration ranges were 0.01 - 0.16%w/v for Amodiaquine hydrochloride and 0.01 – 0.2%w/v for

  13. Thermoluminescent properties of polycrystalline carbon doped LaAlO3/La(OH)3 crystals synthesized by solid state reaction for application in UV dosimetry

    International Nuclear Information System (INIS)

    Alves, N.; Oliveira de F, L.; Barbosa F, W.

    2017-10-01

    It is well known that UV radiation can induce certain deleterious effects, such as erythema, painful inflammation of the membrane of the eye and skin cancer. Therefore, it has been pushing the research for producing new and high performance UV sensitive Tl materials. There is an increasing interest in the development of new Tl materials for ultraviolet (UV) dosimetry purposes, owing to simplicity of the sample readout compared to other techniques. In this paper, thermoluminescence and dosimetric characteristics of pure and carbon doped lanthanum aluminate and hydroxide lanthanum crystals, irradiated with different UV doses, were studied and discussed. All samples studied were produced by solid state reaction method with different mixing methodologies. Characterization of sintered powders by X-ray diffraction, UV-Vis spectrophotometry and Ftir spectroscopy were performed. XRD data confirmed the LaAlO 3 and La(OH) 3 crystalline phases. The thermoluminescent study revealed that all compositions presented high UV sensibility. The sample which was grown by first sintering La 2 O 3 together carbon atoms and then sintering again in order to obtain La 2 O 3 :C together Al 2 O 3 , presented the best linear dose response over UV doses ranging from 0.042 to 0.63 mJ/cm 2 , with correlation coefficients equal to 0.99931. The synthesis methodology used was very efficient to obtain crystals with high Tl output intensities for low exposure rate UV R fields. (Author)

  14. Determination of micro amounts of praseodymium by analogue derivative spectrophotometry

    International Nuclear Information System (INIS)

    Ishii, Hajime; Satoh, Katsuhiko.

    1986-01-01

    Derivative spectrophotometry using the analogue differentiation circuit was applied to the determination of praseodymium at the ppm level. By the proposed method, in which the second or fourth derivative spectrum of the characteristic absorption band of praseodymium(III) at 444 nm is measured, as little as 3 ppm of praseodymium can be determined directly and easily even in the presence of large amounts of other rare earths without any prior separation. Interferences from neodymium, samarium, dysprosium, holmium and erbium ions which have characteristic absorption bands around 444 nm can easily be removed by utilizing the isosbestic point in the derivative spectra of praseodymium(III) and the interfering rare earth(III). (author)

  15. Study of Biological Pigments by Single Specimen Derivative Spectrophotometry

    Science.gov (United States)

    Goldstein, Jack M.

    1970-01-01

    The single specimen derivative (SSD) method provides an absolute absorption spectrum of a substance in the absence of a suitable reference. Both a reference and a measuring monochromatic beam pass through a single sample, and the specimen itself acts as its own reference. The two monochromatic beams maintain a fixed wavelength difference upon scanning, and the difference in absorbance of the two beams is determined. Thus, the resulting spectrum represents the first derivative of the conventional type absorption spectrum. Tissues and cell fractions have been examined at room and liquid N2 temperature and chromophoric molecules such as the mitochondrial cytochromes and blood pigments have been detectable in low concentrations. In the case of isolated cellular components, the observed effects of substrates and inhibitors confirm similar studies by conventional spectrophotometry. The extension of the SSD concept to the microscopic level has permitted the study of the tissue compartmentalization and function of cytochromes and other pigments within layered tissue. PMID:4392452

  16. Determination of serum albumin with tribromoarsenazo by spectrophotometry

    Directory of Open Access Journals (Sweden)

    Qing-Zhou Zhai

    2007-08-01

    Full Text Available The reaction of tribromoarsenazo(TB-ASA with serum albumin in the presence of emulgent OP was studied by spectrophotometry. In a Britton-Robinson buffer solution at pH 2.9, tribromoarsenazo and bovine serum albumin can immediately form a red compound in the presence of emulgent OP with a maximum absorption wavelength at 354 nm. The presence of emulgent OP can increase the reaction sensitivity and the compound stability. The molar absorptivity of the compound is ε354 nm = 6.13 x 105 M-1•cm-1. Beer's law is obeyed over the range of 5.0-75.0 mg•L-1 for bovine serum albumin. The present method was applied to the determination of the total proteins in human serums with satisfactory results.

  17. UV-VIS Spectroscopy Applied to Stratospheric Chemistry, Methods and Results

    Energy Technology Data Exchange (ETDEWEB)

    Karlsen, K.

    1996-03-01

    This paper was read at the workshop ``The Norwegian Climate and Ozone Research Programme`` held on 11-12 March 1996. Numerous observations and modeling have shown with a very high degree of certainty that the man-made emissions of chlorofluorocarbons (CFC) and halons are responsible for the Antarctica ozone hole. It is also evident that the ozone layer of the Northern Hemisphere has suffered a certain decline over the last 10-15 years, possibly because of CFC and halons. 20-30% of the observed reduction is ascribed to coupled chlorine and bromine chemistry via a catalytic cycle resulting in the net conversion of 2O{sub 3} to 3O{sub 2}. But the details are not fully understood. The author plans to assemble a UV-VIS spectrometer for measuring the species OClO and BrO and to compare and discuss measured diurnal variations of OClO and BrO with model calculations. The use of Differential Optical Absorption Spectroscopy (DOAS) is discussed and some results from late 1995 presented. 6 refs., 2 figs.

  18. Development of a non-thermal accelerated pulsed UV photolysis assisted digestion method for fresh and dried food samples

    International Nuclear Information System (INIS)

    Solis, C.; Lagunas-Solar, M.C.; Perley, B.P.; Pina, C.; Aguilar, L.F.; Flocchini, R.G.

    2002-01-01

    A simple, fast digestion procedure for fresh and dried foods, using high-power pulsed UV photolysis in the presence of hydrogen peroxide, is being developed. The homogenized food samples were mixed with H 2 O 2 or with a mixture of H 2 O 2 and HNO 3 , and irradiated for short times with a 248-nm UV excimer laser. After centrifugation, a clear, colorless solution was obtained and aliquots were deposited on Teflon filters for XRF and/or PIXE analyses. Standard reference materials (NIST Peach Leaves; Typical Diet) were also analyzed to compare recoveries and detection limits. Improvements in detection limits were observed, but a few trace elements (<1 ppm) were not reproducibly detected (Fe, Sr). This method proved to be practical for the accelerated digestion of food samples and preparing analytes in short-time intervals. In combination with PIXE and XRF, it allows high-sensitivity multi-elemental analyses for screening the nutritional elements and for food safety purposes regarding the potential presence of toxic elements. Further development to optimize and validate this procedure for a broader range of analytes is in progress

  19. Comparison of gas chromotography, spectrophotometry and near infrared spectroscopy to quantify prussic acid potential in forages.

    Science.gov (United States)

    Goff, Ben M; Moore, Kenneth J; Fales, Steven L; Pedersen, Jeffery F

    2011-06-01

    Sorghum [Sorghum bicolor (L.) Moench] has been shown to contain the cyanogenic glycoside dhurrin, which is responsible for the disorder known as prussic acid poisoning in livestock. The current standard method for estimating hydrogen cyanide (HCN) uses spectrophotometry to measure the aglycone, p-hydroxybenzaldehyde (p-HB), after hydrolysis. Errors may occur due to the inability of this method to solely estimate the absorbance of p-HB at a given wavelength. The objective of this study was to compare the use of gas chromatography (GC) and near infrared spectroscopy (NIRS) methods, along with a spectrophotometry method to estimate the potential for prussic acid (HCNp) of sorghum and sudangrasses over three stages maturities. It was shown that the GC produced higher HCNp estimates than the spectrophotometer for the grain sorghums, but lower concentrations for the sudangrass. Based on what is known about the analytical process of each method, the GC data is likely closer to the true HCNp concentrations of the forages. Both the GC and spectrophotometry methods yielded robust equations with the NIRS method; however, using GC as the calibration method resulted in more accurate and repeatable estimates. The HCNp values obtained from using the GC quantification method are believed to be closer to the actual values of the forage, and that use of this method will provide a more accurate and easily automated means of quantifying prussic acid. Copyright © 2011 Society of Chemical Industry.

  20. Development and Validation of UV-Visible Spectrophotometric Methods for Simultaneous Estimation of Thiocolchicoside and Dexketoprofen in Bulk and Tablet Dosage Form

    OpenAIRE

    M. T. Harde; S. B. Jadhav; D. L. Dharam; P. D. Chaudhari

    2012-01-01

    Development and validation of two simple, accurate, precise and economical UV Spectrophotometric methods for simultaneous estimation of Thiocolchicoside and Dexketoprofen in bulk and in tablet dosage form. The methods employed were Method-1 Absorbance correction method and Method-2 First order derivative spectroscopic method. In method-1 Absorbance is measured at two wavelengths 370nm at which Dexketoprofen has no absorbance and 255nm at which both the drug have considerable absorbance. In me...

  1. Spectrophotometry of peculiar B and A stars

    International Nuclear Information System (INIS)

    Adelman, S.J.

    1980-01-01

    Spectrophotometry of the optical region lambda lambda 3300-7100 is presented for seven magnetic Ap stars: HD 32650, 84 Ursa Majoris, HD 149822, 19 Lyrae, 4 Cygni, HD 196178, and 108 Aquarii. The energy distributions of all seven stars show definite lambda 4200 and lambda 5200 broad, continuum features as well as other more subtle deviations from the predictions of normal stellar atmospheres. The observations of HD 32650 violate the general rule for the Ap stars that the temperature found by comparing the Balmer jump regions with the predictions of normal stalle atmospheres with log g = 4.0 are systematically greater than those found from fitting the slopes of the Paschen continua. (orig.)

  2. Optical imagery and spectrophotometry of CTB 80

    Science.gov (United States)

    Hester, J. Jeff; Kulkarni, Shrinivas R.

    1989-01-01

    Narrow-band imagery and spectrophotometry of the central region of CTB 80 are presented. The images show weak forbidden O III and ubiquitous filamentary forbidden S II and H-alpha emission from the extended radio lobes in which the core is embedded. The data indicate that the extended component is shock heated. Balmer line-dominated emission is observed around the perimeter of the core. Assuming that the volume of the radio shell is similar to the volume of the thermal shell, it is found that a magnetic field of about 600 microG and a cosmic-ray proton-to-electron ratio of about 200 are required to explain the pressure and synchrotron volume emissivity in the radio shell. It is suggested that the optical emission form the core of CTB 80 arises behind shocks which are being driven into a magnetized thermal plasma by the confined relativistic wind from PSR 1951+32.

  3. Spectrophotometry of the shell around AG Carinae

    Science.gov (United States)

    Mitra, P. Mila; Dufour, Reginald J.

    1990-01-01

    Spatially-resolved long-slit spectrophotometry are presented for two regions of the shell nebula around the P-Cygni variable star AG Carinae. The spectra cover the 3700-6800 A wavelength range. Emission-line diagnostics are used to derive extinction, electron temperatures, and densities for various positions in the nebula. The chemical abundances and ionization structure are calculated and compared with other types of planetary nebulae and shells around other luminous stars. It is found that the N/O and N/S ratios of Ag Car are high compared to solar neighborhood ISM values. The O/H depletion found for the AG Car shell approaches that found in the condensations of the Eta Car system.

  4. Development and Validation of a Stability-Indicating LC-UV Method ...

    African Journals Online (AJOL)

    Keywords: Ketotifen, Cetirizine, Stability indicating method, Stressed conditions, Validation. Tropical ... in biological fluids [13] are also reported. Stability indicating HPLC method is reported for ketotifen where drug is ..... paracetamol, cetirizine.

  5. Net Analyte Signal Standard Additions Method for Simultaneous Determination of Sulfamethoxazole and Trimethoprim in Pharmaceutical Formulations and Biological Fluids

    OpenAIRE

    Givianrad, M. H.; Mohagheghian, M.

    2012-01-01

    The applicability of a novel net analyte signal standard addition method (NASSAM) to the resolving of overlapping spectra corresponding to the sulfamethoxazole and trimethoprim was verified by UV-visible spectrophotometry. The results confirmed that the net analyte signal standard additions method with simultaneous addition of both analytes is suitable for the simultaneous determination of sulfamethoxazole and trimethoprim in aqueous media. Moreover, applying the net analyte signal standard a...

  6. Simple and Selective HPLC-UV/Vis Bioanalytical Method to Determine Aluminum Phthalocyanine Chloride in Skin Permeation Studies

    Directory of Open Access Journals (Sweden)

    Thaiene Avila Reis

    2018-01-01

    Full Text Available Considering the feasibility of the aluminum phthalocyanine chloride (AlPcCl application in the topical photodynamic therapy of cutaneous tumors and the lack of HPLC methods capable of supporting skin permeation experiments using this compound, the aim of this study was to obtain a simple and selective chromatographic method for AlPcCl determination in skin matrices. A HPLC-UV/Vis method was developed using a normal-phase column operating at 30°C, an isocratic mobile phase of methanol : phosphoric acid (0.01 M at 1.5 mL/min, and detection at 670 nm. The method exhibited (i selectivity against various contaminants found in the different skin layers, (ii high drug extraction capacity from the hair follicle (>70% and remaining skin (>80%, and (iii low limits of detection and of quantification (0.03 and 0.09 μg/mL, resp.. The method was also linear in the range from 0.1 to 5.0 µg/mL (r = 0.9994 and demonstrated robustness with regard to experimental chromatographic parameters according to a factorial design. Lastly, the developed method was successfully tested in in vitro skin permeation studies of AlPcCl, proving its effectiveness in the development of pharmaceutical delivery systems containing this drug for topical photodynamic therapy of skin cancers.

  7. Formaldehyde in Alcoholic Beverages: Large Chemical Survey Using Purpald Screening Followed by Chromotropic Acid Spectrophotometry with Multivariate Curve Resolution

    Directory of Open Access Journals (Sweden)

    Julien A. Jendral

    2011-01-01

    Full Text Available A strategy for analyzing formaldehyde in beer, wine, spirits, and unrecorded alcohol was developed, and 508 samples from worldwide origin were analyzed. In the first step, samples are qualitatively screened using a simple colorimetric test with the purpald reagent, which is extremely sensitive for formaldehyde (detection limit 0.1 mg/L. 210 samples (41% gave a positive purpald reaction. In the second step, formaldehyde in positive samples is confirmed by quantitative spectrophotometry of the chromotropic acid-formaldehyde derivative combined with Multivariate Curve Resolution-Alternating Least Squares (MCR-ALS. Calculation of UV-VIS and 13C NMR spectra confirmed the monocationic dibenzoxanthylium structure as the product of the reaction and disproved the widely cited para,para-quinoidal structure. Method validation for the spectrophotometric procedure showed a detection limit of 0.09 mg/L and a precision of 4.2–8.2% CV. In total, 132 samples (26% contained formaldehyde with an average of 0.27 mg/L (range 0–14.4 mg/L. The highest incidence occurred in tequila (83%, Asian spirits (59%, grape marc (54%, and brandy (50%. Our survey showed that only 9 samples (1.8% had formaldehyde levels above the WHO IPCS tolerable concentration of 2.6 mg/L.

  8. Formaldehyde in alcoholic beverages: large chemical survey using purpald screening followed by chromotropic Acid spectrophotometry with multivariate curve resolution.

    Science.gov (United States)

    Jendral, Julien A; Monakhova, Yulia B; Lachenmeier, Dirk W

    2011-01-01

    A strategy for analyzing formaldehyde in beer, wine, spirits, and unrecorded alcohol was developed, and 508 samples from worldwide origin were analyzed. In the first step, samples are qualitatively screened using a simple colorimetric test with the purpald reagent, which is extremely sensitive for formaldehyde (detection limit 0.1 mg/L). 210 samples (41%) gave a positive purpald reaction. In the second step, formaldehyde in positive samples is confirmed by quantitative spectrophotometry of the chromotropic acid-formaldehyde derivative combined with Multivariate Curve Resolution-Alternating Least Squares (MCR-ALS). Calculation of UV-VIS and (13)C NMR spectra confirmed the monocationic dibenzoxanthylium structure as the product of the reaction and disproved the widely cited para,para-quinoidal structure. Method validation for the spectrophotometric procedure showed a detection limit of 0.09 mg/L and a precision of 4.2-8.2% CV. In total, 132 samples (26%) contained formaldehyde with an average of 0.27 mg/L (range 0-14.4 mg/L). The highest incidence occurred in tequila (83%), Asian spirits (59%), grape marc (54%), and brandy (50%). Our survey showed that only 9 samples (1.8%) had formaldehyde levels above the WHO IPCS tolerable concentration of 2.6 mg/L.

  9. Spectrophotometry or visual inspection to most reliably detect xanthochromia in subarachnoid hemorrhage: systematic review.

    Science.gov (United States)

    Chu, Kevin; Hann, Angus; Greenslade, Jaimi; Williams, Julian; Brown, Anthony

    2014-09-01

    We assess the sensitivity and specificity of xanthochromia as adjudicated by visual inspection and spectrophotometry at predicting the presence of cerebral aneurysm in patients with suspected subarachnoid hemorrhage who have a normal computed tomography (CT) head scan result. A systematic review was performed. MEDLINE and EMBASE databases were searched. Relevant studies with clinical data on the diagnostic accuracy of visual inspection or spectrophotometry were considered. Patients who had a normal CT head scan result followed by a lumbar puncture were included in this review. Sensitivities, specificities, and heterogeneity (I(2)) were calculated. Subgroup analyses were performed to explore reasons for the heterogeneity. There were major methodological limitations in the studies found. Twenty-two relevant articles were heterogeneous in regard to time to lumbar puncture, spectrophotometry methods, and follow-up of patients not undergoing cerebral angiography. Twelve of the 22 studies selected patients on the basis of a cerebral aneurysm or subarachnoid hemorrhage on imaging, or a positive lumbar puncture result. These studies were excluded from our initial analysis, which included only patients with clinically suspected subarachnoid hemorrhage. In this initial analysis, pooled estimates of sensitivity and specificity for spectrophotometry were 87% (95% confidence interval [CI] 71% to 96%; I(2)=26%) and 86% (95% CI 84% to 88%; I(2)=96%), respectively. For visual inspection, pooled sensitivity and specificity were 83% (95% CI 59% to 96%; I(2)=52%) and 96% (95% CI 93% to 97%; I(2)=76%), respectively. Sensitivity estimates are difficult to interpret without knowing time to lumbar puncture. The heterogeneity in the underlying studies, combined with significant overlap in pooled confidence limits, makes it impossible to provide a definite conclusion about the diagnostic accuracy of spectrophotometry versus visual inspection. Copyright © 2014 American College of Emergency

  10. Monitoring of monosaccharides, oligosaccharides, ethanol and glycerol during wort fermentation by biosensors, HPLC and spectrophotometry.

    Science.gov (United States)

    Monošík, Rastislav; Magdolen, Peter; Stredanský, Miroslav; Šturdík, Ernest

    2013-05-01

    The aim of the present study was to analyze sugar levels (namely maltose, maltotriose, glucose and fructose) and alcohols (ethanol and glycerol) during the fermentation process in wort samples by amperometric enzymatic biosensors developed by our research group for industrial application, HPLC and spectrophotometry, and to compare the suitability of the presented methods for determination of individual analytes. We can conclude that for the specific monitoring of maltose or maltotriose only the HPLC method was suitable. On the other hand, biosensors and spectrophotometry reflected a decrease in total sugar concentration better and were able to detect both glucose and fructose in the later stages of fermentation, while HPLC was not. This can be attributed to the low detection limits and good sensitivity of the proposed methods. For the ethanol and glycerol analysis all methods proved to be suitable. However, concerning the cost expenses and time analysis, biosensors represented the best option. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Determination of tantalum in standard steels by INAA and absorption spectrophotometry

    Energy Technology Data Exchange (ETDEWEB)

    Obrusnik, I; Posta, S [Ustav Jaderneho Vyzkumu, Rez (Czechoslovakia)

    1978-02-14

    Two analytical methods, instrumental neutron activation analysis (INAA) and absorption spectrophotometry with malachite green, have been used for the determination of tantalum in standard steels produced by the Research Institute of CKD Prague - steels No. 167 and No. 169 with expected concentrations of Ta 0.01% and 0.03%, respectively. INAA method consisted of irradiation of steel samples (chips) in a nuclear reactor and Ge(Li) ..gamma..-ray spectrometry after a cooling period of one month. A spectrophotometric determination is based on the extraction of ionic associate of TaF/sub 6//sup -/ with malachite green into Oenzene from a solution of diluted sulphuric acid and hydrofluoric acid. The results obtained by the two methods are in a good agreement. However, INAA method is more sensitive and precise then spectrophotometry for the determination of tantalum in steels in the above-mentioned concentration ranges.

  12. Determination of tantalum in standard steels by INAA and absorption spectrophotometry

    International Nuclear Information System (INIS)

    Obrusnik, I.; Posta, S.

    1978-01-01

    Two analytical methods, instrumental neutron activation analysis (INAA) and absorption spectrophotometry with malachite green, have been used for the determination of tantalum in standard steels produced by the Research Institute of CKD Prague - steels No. 167 and No. 169 with expected concentrations of Ta 0.01% and 0.03%, respectively. INAA method consisted of irradiation of steel samples (chips) in a nuclear reactor and Ge(Li) γ-ray spectrometry after a cooling period of one month. A spectrophotometric determination is based on the extraction of ionic associate of TaF 6 - with malachite green into Oenzene from a solution of diluted sulphuric acid and hydrofluoric acid. The results obtained by the two methods are in a good agreement. However, INAA method is more sensitive and precise then spectrophotometry for the determination of tantalum in steels in the above-mentioned concentration ranges. (author)

  13. PHOTODEGRADATION OF ALIZARIN S DYE USING TiO2-ZEOLITE AND UV RADIATION

    Directory of Open Access Journals (Sweden)

    Karna Wijaya

    2010-06-01

    Full Text Available An investigation of Alizarin S photodegradation using TiO2-zeolite and UV radiation was performed. TiO2-zeolite was prepared by dispersing oligocations of titanium into suspension of zeolite. The suspension was stirred and then filtered to separate the solid phase from the filtrate. the solid phase was calcined by microwave oven at 800 Watt for 5 minutes to convert the oligocations into its oxide forms. The calcined product and unmodified zeolite were characterized using x-ray diffractometry, FT-IR spectrophotometry, X-ray fluorescence and gas sorption analysis methods to determine their physicochemical properties. Photocatalytic activity of TiO2-zeolite was tested on Alizarin S solution using following method: 50 mg of zeolite was dispersed into 25 mL of 10-4 M Alizarin S. The dispersion was irradiated using 365 nm UV light at room temperature on various irradiation times, i.e. 10, 20, 30, 40 and 60 minutes. At certain irradiation time, the dispersion was filtered and the filtrate was then analyzed its concentration using UV-Vis spectrophotometry method. Characterization results exhibited that the formation of TiO2 on internal as well as external surfaces of zeolite could not be detected  with x-ray diffractometry and FT-IR spectrophotometry, however determination of titanium using x-ray fluorescence analysis on the calcined product showed that the concentration of titanium was much higher than zeolite (0.22% on zeolite and 12.08% on TiO2-zeolite. Gas sorption analysis result indicated that the the calcination  resulted in the increase of specific surface area (16,31 m2/g on zeolite and 100.96 m2/g on TiO2-zeolite as well as total pore volume of calcined product (13.34 mL/Å/g on zeolite and 57.54 mL/Å/g on TiO2-zeolite. The result of photocatalytic activitiy study showed that ca 99 % of Alizarin S was degraded by TiO2-zeolite after UV irradiation for 60 min.   Keywords: TiO2-zeolite, photocatalytic, Alizarin S.

  14. Determination of Tetracycline in Pharmaceutical Preparation by Molecular and Atomic Absorption Spectrophotometry and High Performance Liquid Chromatography via Complex Formation with Au(III) and Hg(II) Ions in Solutions

    Science.gov (United States)

    Abdulghani, Ahlam Jameel; Jasim, Hadi Hassan; Hassan, Abbas Shebeeb

    2013-01-01

    UV-visible and atomic spectrophotometry and HPLC techniques were applied for the determination of tetracycline (TC) in pharmaceutical preparations via complexation of the drug with Au(III) and Hg(II) ions in solutions. The mole ratio of TC to metal ions was 1 : 1. Maximum peak absorption at λ 425 and 320 nm for the two ions, respectively, was optimized at heating temperature 75°C for 15 minutes at pH = 4 followed by the extraction with ethyl acetate. The percentage of extraction and stability constants for the two complexes was 95.247, 95.335% and 2.518 × 104, 1.162 × 105 M−1, respectively. HPLC method was applied without extraction process. The analytical data obtained from direct calibration curves of UV-visible absorption, FAAS, and HPLC for Au(III) complexes were recovery (100.78, 104.85, and 101.777%, resp.); detection limits (0.7403, 0.0997, and 2.647 μg/ml, resp.); linearity (5–70, 5–30, and 10–150 μg/ml, resp.), and correlation coefficient (0.9991, 0.9967, and 0.9986, resp.). The analytical data obtained from direct calibration curves for Hg(II) complexes by UV-visible spectrophotometry and HPLC were recovery (100.95 and 102.000%, resp.); detection limits (0.5867 and 2.532 μg/ml, resp.); linearity (5–70 and 10–150 μg/ml, resp.); and correlation coefficients (0.9989 and 0.9997, resp.). PMID:23853607

  15. Visible and UV photo-detection in ZnO nanostructured thin films via simple tuning of solution method.

    Science.gov (United States)

    Khokhra, Richa; Bharti, Bandna; Lee, Heung-No; Kumar, Rajesh

    2017-11-08

    This study demonstrates significant visible light photo-detection capability of pristine ZnO nanostructure thin films possessing substantially high percentage of oxygen vacancies [Formula: see text] and zinc interstitials [Formula: see text], introduced by simple tuning of economical solution method. The demonstrated visible light photo-detection capability, in addition to the inherent UV light detection ability of ZnO, shows great dependency of [Formula: see text] and [Formula: see text] with the nanostructure morphology. The dependency was evaluated by analyzing the presence/percentage of [Formula: see text] and [Formula: see text] using photoluminescence (PL) and X-ray photoelectron spectroscopy (XPS) measurements. Morphologies of ZnO viz. nanoparticles (NPs), nanosheets (NSs) and nanoflowers (NFs), as a result of tuning of synthesis method contended different concentrations of defects, demonstrated different photo-detection capabilities in the form of a thin film photodetector. The photo-detection capability was investigated under different light excitations (UV; 380~420 nm, white ; λ > 420 nm and green; 490~570 nm). The as fabricated NSs photodetector possessing comparatively intermediate percentage of [Formula: see text] ~ 47.7% and [Formula: see text] ~ 13.8% exhibited superior performance than that of NPs and NFs photodetectors, and ever reported photodetectors fabricated by using pristine ZnO nanostructures in thin film architecture. The adopted low cost and simplest approach makes the pristine ZnO-NSs applicable for wide-wavelength applications in optoelectronic devices.

  16. Preparation of flower-like CuS by solvothermal method for photocatalytic, UV protection and EMI shielding applications

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Xiao-Sai; Shen, Yong, E-mail: shenyong@sues.edu.cn; Xu, Li-Hui; Wang, Li-Ming; Lu, Li-sha; Zhang, Ya-ting

    2016-11-01

    Highlights: • The flower-like CuS was synthesized by a facil solvothermal method. • The as-prepared flower-like CuS showed better solar light-driven photocatalytic activity. • The as-prepared CuS could act as a novel UV blocker. • The flower-like CuS potentially hold promise as electromagnetic shielding material. - Abstract: The flower-like CuS hierarchical structures were synthesized by solvothermal method. The as-prepared products were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), Fourier transform infrared(FTIR) spectroscopy, UV–vis optical absorption spectroscopy and thermogravimetric analysis (TGA). The results demonstrated that the as-prepared flower-like CuS with the diameter of 1–5 um was pure hexagonal phase CuS and had well-defined flower-like structures. (1) The as-prepared CuS was proved to possess high photocatalytic performance with band gap of 1.45 eV. The degradation rate of Methylene blue (MB) was up to, 98.26%, 100% after 30 min under UV and visible irradiation. (2)The UPF of cotton fabric treated with CuS reached up to 174 compared with the original untreated fabric with the UPF 20.62. (3) The electromagnetic interference shielding effectiveness (EMI SE) of CuS coating was up to 27–31 dB when the content of CuS increased to 28.6%wt in the frequency of 300 KHz–3 GHz. Furthermore, the influence of reaction conditions on the morphology of the as-prepared CuS was investigated systematically and the possible formation mechanism of the CuS hierarchical structure was also proposed.

  17. The analysis of coal-and coke ashes by atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Coutinho, C.A.; Prates, H.T.; Pereira, C.P.

    1977-01-01

    In order to provide better conditions for the control of the chemical composition of the load in the USIMINAS blast furnaces, a method of analysis for sodium, potassium, iron, aluminium, calcium, magnesium and maganese in coal-and coke ash by atomic absorption spectrophotometry was developed. The precision of the calibration curves and the reproducibility of the results are given, together with an estimate of the speed compared with conventional methods of chemical analysis [pt

  18. Evaluation and Comparison of Chemiluminescence and UV Photometric Methods for Measuring Ozone Concentrations in Ambient Air

    Science.gov (United States)

    The current Federal Reference Method (FRM) for measuring concentrations of ozone in ambient air is based on the dry, gas-phase, chemiluminescence reaction between ethylene (C2H4) and any ozone (O3) that may be p...

  19. Operator care and eco-concerned development of a fast, facile and economical assay for basic nitrogenous drugs based on simplified ion-pair mini-scale extraction using safer solvent combined with drop-based spectrophotometry.

    Science.gov (United States)

    Plianwong, Samarwadee; Sripattanaporn, Areerut; Waewsa-nga, Kwanrutai; Buacheen, Parin; Opanasopit, Praneet; Ngawhirunpat, Tanasait; Rojanarata, Theerasak

    2012-08-30

    A fast, facile, and economical assay for basic nitrogenous drugs has been developed based on the mini-scale extraction of the drug-dye ion pair complex combined with the use of safe-for-analyst and eco-friendlier organic extractant and drop-based micro-spectrophotometry. Instead of using large volume devices, the extraction was simply carried out in typical 1.5 mL microcentrifuge tubes along with the use of micropipettes for accurate transfer of liquids, vortex mixer for efficient partitioning of solutes and benchtop centrifuge for rapid phase separation. In the last step, back-extraction was performed by using the microvolume of acidic solution in order to concentrate the colored species into a confined aqueous microdrop and to keep the analyst away from unwanted contact and inhalation of organic solvents during the quantitation step which was achieved by using cuvetteless UV-vis micro-spectrophotometry without any prior dilutions. Using chlorpheniramine maleate as a representative analyte and n-butyl acetate as a less toxic and non-ozone depleting extractant, the miniaturized method was less laborious and much faster. It was accurate, precise and insensitive to the interferences from common excipients. Notably, it gave the assay results of drug in tablets and oral solution comparable to the large-scale pharmacopeial method while the consumption of organic solvents and the release of wastes were lowered by 200-400 folds. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Indirect determination of uranium by atomic-absorption spectrophotometry using an air-acetylene flame

    International Nuclear Information System (INIS)

    Alder, J.F.; Das, B.C.

    1977-01-01

    An indirect method has been developed for the determination of uranium by atomic-absorption spectrophotometry using an air-acetylene flame. Use is made of the reduction of copper(II) by uranium(IV) followed by complex formation of the copper(I) ions so produced with neocuproine (2,9-dimethyl-1,10-phenanthroline) and finally the determination of copper in this complex by atomic-absorption spectrophotometry. The results show that the method can be recommended, provided that care is taken to ensure the complete reduction of uranium(VI) to uranium(IV). The sensitivity of the method is 4.9 μg of uranium and the upper limit 500 μg without dilution. (author)

  1. Quantitative determination of triterpene saponins and alkenated-phenolics from Labisia pumila using LC-UV/ELSD method and confirmation by LC-ESI-TOF

    Science.gov (United States)

    This study describes the first analytical method for the determination of saponins and alkenated-phenolics from the leaves, leaves/stems and roots of Labisia pumila using a HPLC-UV-ELSD method. The separation was achieved using a reversed phase column, PDA and ELS detection, and a water/acetonitrile...

  2. Quantitative determination of triperpene saponins and alkenated-phenolics from Labisia pumila using LC-UV/ELSD method and confirmation by LC-ESI-TOF

    Science.gov (United States)

    This study describes the first analytical method for the determination of saponins and alkenated-phenolics from the leaves, leaves/stems and roots of Labisia pumila using a HPLC-UV-ELSD method. The separation was achieved using a reversed phase column, PDA and ELS detection, and a water/acetonitrile...

  3. Analysis of N-nitrosodiethylamine by ion chromatography coupled with UV photolysis pretreatment

    Directory of Open Access Journals (Sweden)

    Xueli Li

    2016-04-01

    Full Text Available Nitrosamines such as N-nitrosodiethylamine (NDEA are commonly detected by spectrophotometry after photolysis and Griess reaction (PG in food industries for lower cost. Results of this research indicate that NDEA decays rapidly under UV irradiation, and concentrations of the generated NO2− and NO3− ions vary with photolysis conditions. Thus, the measurement of the PG method may be inconsistent because it is based on the amount of photoproduced NO2−. In addition, more errors may be present in the PG method since NO3− cannot be measured colorimetrically using Griess reagent. In this work, the sum of the concentrations of photoproduced NO2− and NO3− was found to be equivalent to the initial NDEA before photolysis, and a photolysis–ion chromatography method was validated, which may serve as a feasible and accurate method to determine nitrosamines.

  4. Development and Validation of UV Spectrophotometric Method For Estimation of Dolutegravir Sodium in Tablet Dosage Form

    International Nuclear Information System (INIS)

    Balasaheb, B.G.

    2015-01-01

    A simple, rapid, precise and accurate spectrophotometric method has been developed for quantitative analysis of Dolutegravir sodium in tablet formulations. The initial stock solution of Dolutegravir sodium was prepared in methanol solvent and subsequent dilution was done in water. The standard solution of Dolutegravir sodium in water showed maximum absorption at wavelength 259.80 nm. The drug obeyed Beer-Lamberts law in the concentration range of 5-40 μg/ mL with coefficient of correlation (R"2) was 0.9992. The method was validated as per the ICH guidelines. The developed method can be adopted in routine analysis of Dolutegravir sodium in bulk or tablet dosage form and it involves relatively low cost solvents and no complex extraction techniques. (author)

  5. Development and Validation of a UV Spectrophotometric and a RP-HPLC Methods for Moexipril Hydrochloride in Pure Form and Pharmaceutical Dosage Form

    International Nuclear Information System (INIS)

    Mastiholimath, V.S.; Gupte, P.P.; Mannur, V.S.

    2012-01-01

    A simple and reliable UV spectrophotometric and high-performance liquid chromatography (HPLC) methods were developed and validated for Moexipril hydrochloride in pure form and pharmaceutical dosage form. The RP-HPLC method was developed on agilant eclipse C 18 , (150 mm x 4.6 mm, 5 μm) with a mobile phase gradient system of 60 % (methanol:acetonitrile (70:30 % v/v)) : 40 % 20 mM ammonium acetate buffer pH 4.5 (v/v) and UV spectrophotometric method was developed in phosphate buffer pH 6.8. The effluent was monitored by SPD-M20A, prominence PDA detector at 210 nm. Calibration curve was linear over the concentration range of 10-35 μg/ml and 1-9 μg/ml for RP-HPLC and UV with a regression coefficient of 0.999. For RP-HPLC method Inter-day and intra-day precision % RSD values were found to be 1.00078 % and 1.49408 % respectively. For UV method 0.73386 % to 1.44111 % for inter day 0.453864 to 1.15542 intra-day precision. Recovery of Moexipril hydrochloride was found to be in the range of 99.8538 % to 101.5614 % and 100.5297586 % to 100.6431587 % for UV and RP-HPLC respectively. The limits of detection (LOD) and quantification (LOQ) for HPLC were 0.98969 and 2.99907 μg/ml, respectively. The developed RP-HPLC and UV spectrophotometric method was successfully applied for the quantitative determination of Moexipril hydrochloride in pharmaceutical dosage. (author)

  6. Development and Validation of a Stability-Indicating LC-UV Method ...

    African Journals Online (AJOL)

    Pharmacotherapy Group, Faculty of Pharmacy, University of Benin, Benin City, 300001 Nigeria. All rights reserved. Available online at http://www.tjpr.org ... dihydrochloride in solid dosage forms. Methods: Chromatographic separation was achieved on Grace Smart C18 column (250 × 4.6 mm, 5 μm) using an isocratic mobile ...

  7. Development and validation of a UV-spectrophotometric method for the determination of pheniramine maleate and its stability studies

    Science.gov (United States)

    Raghu, M. S.; Basavaiah, K.; Ramesh, P. J.; Abdulrahman, Sameer A. M.; Vinay, K. B.

    2012-03-01

    A sensitive, precise, and cost-effective UV-spectrophotometric method is described for the determination of pheniramine maleate (PAM) in bulk drug and tablets. The method is based on the measurement of absorbance of a PAM solution in 0.1 N HCl at 264 nm. As per the International Conference on Harmonization (ICH) guidelines, the method was validated for linearity, accuracy, precision, limits of detection (LOD) and quantification (LOQ), and robustness and ruggedness. A linear relationship between absorbance and concentration of PAM in the range of 2-40 μg/ml with a correlation coefficient (r) of 0.9998 was obtained. The LOD and LOQ values were found to be 0.18 and 0.39 μg/ml PAM, respectively. The precision of the method was satisfactory: the value of relative standard deviation (RSD) did not exceed 3.47%. The proposed method was applied successfully to the determination of PAM in tablets with good accuracy and precision. Percentages of the label claims ranged from 101.8 to 102.01% with the standard deviation (SD) from 0.64 to 0.72%. The accuracy of the method was further ascertained by recovery studies via a standard addition procedure. In addition, the forced degradation of PAM was conducted in accordance with the ICH guidelines. Acidic and basic hydrolysis, thermal stress, peroxide, and photolytic degradation were used to assess the stability-indicating power of the method. A substantial degradation was observed during oxidative and alkaline degradations. No degradation was observed under other stress conditions.

  8. Transmission of UV-irradiance into nectarine fruit

    International Nuclear Information System (INIS)

    Blanke, M.M.

    1996-01-01

    With the global depletion of the ozone layer, leaves and fruits are increasingly exposed to UV-irradiance on the tree. Some fruits are additionally exposed postharvest to artificial germicidal W-irradiance, leading to a cumulative effect. This paper examines the transmission of UV-light (200-400 nm) by the peel of ripe nectarine fruit using UV/VIS spectrophotometry to aid understanding of UV-effects and assess the sensitivity of the peel to UV wavelengths. Yellow peel of nectarine fruit transmitted less than 0.1 % in the UV-C range of 220 to 280 nm. With longer wavelenghts, UV-light transmission increased slowly from 0.4 % at 284 nm to 1.6 % at 320 nm and, in the UV-A region, progressively from 1.9 % at 330 nm to a maximum of 13 % of incident irradiance at 400 nm. Red peel of nectarine fruit transmitted less than 0.1 % of UV-C and UV-B light, but up to 0.9 % of incident UV-A light at 400 nm. Conversely, UV-absorption of nectarine peel decreased with longer wavelengths. Hence, fruit parenchyma is more affected by UV-irradiance at wavelengths above ca. 280 nm and underneath yellow than underneath red peel

  9. A method of atmospheric density measurements during Shuttle entry using UV laser Rayleigh scattering

    Science.gov (United States)

    Mckenzie, Robert L.

    1987-01-01

    A detailed study is described of the performance capabilities and the hardware requirements for a method in which ambient density is measured along the Space Shuttle flight path using on-board optical instrumentation. The technique relies on Rayleigh scattering of light from a pulsed, ultraviolet, ArF excimer laser operating at a wavelength of 193 nm. The method is shown to be capable of providing direct measurements of ambient density with an uncertainty of less than 1 percent and with a spatial resolution of 1 km, over an altitude range from 50 to 90 km. In addition, extensions of this concept are discussed that allow measurements of the shock wave location and the density profile within the shock layer. Two approaches are identified that appear to be feasible, in which the same laser system is used for the extended measurements as that required for the ambient density measurements.

  10. Rapid Method for the Determination of 5-Hydroxymethylfurfural and Levulinic Acid Using a Double-Wavelength UV Spectroscopy

    Directory of Open Access Journals (Sweden)

    Junhua Zhang

    2013-01-01

    Full Text Available This study reports on a rapid method for the determination of levulinic acid (LA and 5-hydroxymethylfurfural (HMF in acid hydrolyze system of glucose based on UV spectroscopy. It was found that HMF and LA have a maximum absorption at the wavelengths of 284 nm and 266 nm, respectively, in a water medium, and the absorptions of HMF and LA at 284 nm and 266 nm follow Beer’s law very well. However, it was found that a major spectral interference species will arise in the quantification of HMF and LA; nonetheless, this interference can be eliminated through the absorption treatment of charcoal. Therefore, both HMF and LA can be quantified with a double-wavelength technique. The repeatability of the method had a relative standard deviation of less than 4.47% for HMF and 2.25% for LA; the limit of quantification (LOQ was 0.017 mmol/L for HMF and 4.68 mmol/L for LA, and the recovery ranged from 88% to 116% for HMF and from 94% to 105% for LA. The present method is simple, rapid, and accurate. It is suitable to use in the research of the preparation of HMF and LA in biorefinery area.

  11. [Noninvasive total hemoglobin monitoring based on multiwave spectrophotometry in obstetrics and gynecology].

    Science.gov (United States)

    Pyregov, A V; Ovechkin, A Iu; Petrov, S V

    2012-01-01

    Results of prospective randomized comparative research of 2 total hemoglobin estimation methods are presented. There were laboratory tests and continuous noninvasive technique with multiwave spectrophotometry on the Masimo Rainbow SET. Research was carried out in two stages. At the 1st stage (gynecology)--67 patients were included and in second stage (obstetrics)--44 patients during and after Cesarean section. The standard deviation of noninvasive total hemoglobin estimation from absolute values (invasive) was 7.2 and 4.1%, an standard deviation in a sample--5.2 and 2.7 % in gynecologic operations and surgical delivery respectively, that confirms lack of reliable indicators differences. The method of continuous noninvasive total hemoglobin estimation with multiwave spectrophotometry on the Masimo Rainbow SET technology can be recommended for use in obstetrics and gynecology.

  12. UV-induced changes of structural and functional properties of blood lactatedehydrogenase isoenzymes in free sate and in the presence of serotonin

    International Nuclear Information System (INIS)

    Nakvasina, M.A.; Artyukhov, V.G.; Agisheva, N.V.

    1999-01-01

    Photoinduced changes in structural and functional properties of lactatedehydrogenase isoenzymes from human erythrocytes in free state and in the presence of serotonin have been studied by means of gel chromatography, electrophoresis, IR-spectrophotometry and by the method of definition of catalytic activity. UV radiation exposure induces photoinactivation of erythrocytes lactatedehydrogenase, while its inhibitory effect intensifies with the increase of radiation dose. Pronounced photoprotective effect of serotonin towards the molecules of erythrocytic lactatedehydrogenase isoenzymes has been discovered. It seems to be caused by formation of enzyme - biogenic amine complex affecting the secondary protein structure [ru

  13. Development of Micellar HPLC-UV Method for Determination of Pharmaceuticals in Water Samples

    Directory of Open Access Journals (Sweden)

    Danielle Cristina da Silva

    2018-01-01

    Full Text Available Method for extraction and determination of amoxicillin, caffeine, ciprofloxacin, norfloxacin, tetracycline, diclofenac, ibuprofen, nimesulide, levonorgestrel, and 17α-ethynylestradiol exploiting micellar liquid chromatography with PDA detector and solid-phase extraction was proposed. The usage of toxic solvents was low; the chromatographic separation of the medicaments was performed using a C18 column and mobile phases A and B containing 15.0% (v/v ethanol, 3.0% (m/v sodium dodecyl sulfate (SDS, and 0.02 mol·L−1 phosphate at pHs 7.0 and 8.0, respectively. The method is simple, selective, and fast, and the analytes were separated in 23.0 min. For extraction, 1000 mL of sample containing 2.0% (v/v ethanol and 0.002 mol·L−1 citric acid at pH 2.50 was loaded through a 1000 mg of C18 cartridge. The analytes were eluted using 3.0 mL of ethanol, which were evaporated and redissolved in 0.5 mL of mobile phase. Concentration factors better than 1200, except amoxicillin (224, were obtained. The analytical curves were linear (R2 better than 0.992; LOD and LOQ n=10 presented values in the range of 0.019–0.247 and 0.058–0.752 mg·L−1, respectively. Recoveries of 99% were obtained, and the results are in agreement with those obtained by the comparative methods.

  14. Determination of Lead in Urine by Atomic Absorption Spectrophotometry1

    Science.gov (United States)

    Selander, Stig; Cramé, Kim

    1968-01-01

    A method for the determination of lead in urine by means of atomic absorption spectrophotometry (AAS) is described. A combination of wet ashing and extraction with ammonium pyrrolidine dithiocarbamate into isobutylmethylketone was used. The sensitivity was about 0·02 μg./ml. for 1% absorption, and the detection limit was about 0·02 μg./ml. with an instrumental setting convenient for routine analyses of urines. Using the scale expansion technique, the detection limit was below 0·01 μg./ml., but it was found easier to determine urinary lead concentrations below 0·05 μg./ml. by concentrating the lead in the organic solvent by increasing the volume of urine or decreasing that of the solvent. The method was applied to fresh urines, stored urines, and to urines, obtained during treatment with chelating agents, of patients with lead poisoning. Urines with added inorganic lead were not used. The results agreed well with those obtained with a colorimetric dithizone extraction method (r = 0·989). The AAS method is somewhat more simple and allows the determination of smaller lead concentrations. PMID:5647975

  15. UV-treatment in dermatology. Equipment and methods in Norwegian university hospitals

    International Nuclear Information System (INIS)

    Christensen, T.; Johnsen, B.; Johnsson, M.; Nordal, E.; Thune, P.; Kjeldstad, B.; Reitan, J.B.

    1994-12-01

    The use of phototherapy and the phototherapy-equipment were studied in five Norwegian university hospitals. The indications and the methods used were relatively similar, as well as the equipment used for dosimetry. The spectra and irradiance from the phototherapy lamps were measured and the variations in these parameters were evaluated. It is discussed whether there is a need for closer control and standardization of these parameters. The UVA-irradiance that could be experienced by the persons employed in the departments was found to be lower than the recommended limits. 12 refs., 7 figs., 6 tabs

  16. Laser capture microdissection: Arcturus(XT) infrared capture and UV cutting methods.

    Science.gov (United States)

    Gallagher, Rosa I; Blakely, Steven R; Liotta, Lance A; Espina, Virginia

    2012-01-01

    Laser capture microdissection (LCM) is a technique that allows the precise procurement of enriched cell populations from a heterogeneous tissue under direct microscopic visualization. LCM can be used to harvest the cells of interest directly or can be used to isolate specific cells by ablating the unwanted cells, resulting in histologically enriched cell populations. The fundamental components of laser microdissection technology are (a) visualization of the cells of interest via microscopy, (b) transfer of laser energy to a thermolabile polymer with either the formation of a polymer-cell composite (capture method) or transfer of laser energy via an ultraviolet laser to photovolatize a region of tissue (cutting method), and (c) removal of cells of interest from the heterogeneous tissue section. Laser energy supplied by LCM instruments can be infrared (810 nm) or ultraviolet (355 nm). Infrared lasers melt thermolabile polymers for cell capture, whereas ultraviolet lasers ablate cells for either removal of unwanted cells or excision of a defined area of cells. LCM technology is applicable to an array of applications including mass spectrometry, DNA genotyping and loss-of-heterozygosity analysis, RNA transcript profiling, cDNA library generation, proteomics discovery, and signal kinase pathway profiling. This chapter describes the unique features of the Arcturus(XT) laser capture microdissection instrument, which incorporates both infrared capture and ultraviolet cutting technology in one instrument, using a proteomic downstream assay as a model.

  17. Optical properties of orthodontic aligners?spectrophotometry analysis of three types before and after aging

    OpenAIRE

    Lombardo, Luca; Arreghini, Angela; Maccarrone, Roberta; Bianchi, Anna; Scalia, Santo; Siciliani, Giuseppe

    2015-01-01

    Background The aim was to assess and compare absorbance and transmittance values of three types of clear orthodontic aligners before and after two cycles of in vitro aging. Methods Nine samples of orthodontic aligners from three different manufacturers (Invisalign, Align Technology, Santa Clara, CA, USA; All-In, Micerium, Avegno, GE, Italy; F22 Aligner, Sweden & Martina, Due Carrare, PD, Italy) were selected, and each sample was subjected to spectrophotometry analysis of both its transmittanc...

  18. Validation of an HPLC-UV method for the identification and quantification of bioactive amines in chicken meat

    Directory of Open Access Journals (Sweden)

    D.C.S. Assis

    2016-06-01

    Full Text Available ABSTRACT A high-performance liquid chromatography with ultraviolet detection (HPLC-UV method was validated for the study of bioactive amines in chicken meat. A gradient elution system with an ultraviolet detector was used after extraction with trichloroacetic acid and pre-column derivatization with dansyl chloride. Putrescine, cadaverine, histamine, tyramine, spermidine, and spermine standards were used for the evaluation of the following performance parameters: selectivity, linearity, precision, recovery, limits of detection, limits of quantification and ruggedness. The results indicated excellent selectivity, separation of all amines, a coefficient of determination greater than 0.99 and recovery from 92.25 to 102.25% at the concentration of 47.2mg.kg-1, with a limit of detection at 0.3mg.kg-1 and a limit of quantification at 0.9mg.kg-1 for all amines, with the exception of histamine, which exhibited the limit of quantification, of 1mg.kg-1. In conclusion, the performance parameters demonstrated adequacy of the method for the detection and quantification of bioactive amines in chicken meat.

  19. Development and validation of an LC-UV method for the determination of sulfonamides in animal feeds.

    Science.gov (United States)

    Kumar, P; Companyó, R

    2012-05-01

    A simple LC-UV method was developed for the determination of residues of eight sulfonamides (sulfachloropyridazine, sulfadiazine, sulfadimidine, sulfadoxine, sulfamethoxypyridazine, sulfaquinoxaline, sulfamethoxazole, and sulfadimethoxine) in six types of animal feed. C18, Oasis HLB, Plexa and Plexa PCX stationary phases were assessed for the clean-up step and the latter was chosen as it showed greater efficiency in the clean-up of interferences. Feed samples spiked with sulfonamides at 2 mg/kg were used to assess the trueness (recovery %) and precision of the method. Mean recovery values ranged from 47% to 66%, intra-day precision (RSD %) from 4% to 15% and inter-day precision (RSD %) from 7% to 18% in pig feed. Recoveries and intra-day precisions were also evaluated in rabbit, hen, cow, chicken and piglet feed matrices. Calibration curves with standards prepared in mobile phase and matrix-matched calibration curves were compared and the matrix effects were ascertained. The limits of detection and quantification in the feeds ranged from 74 to 265 µg/kg and from 265 to 868 µg/kg, respectively. Copyright © 2011 John Wiley & Sons, Ltd.

  20. Diagnosis of Smith-Lemli-Opitz syndrome by ultraviolet spectrophotometry

    Directory of Open Access Journals (Sweden)

    F.B. Scalco

    2003-10-01

    Full Text Available Smith-Lemli-Opitz syndrome (SLOS is an autosomal recessive disorder due to an inborn error of cholesterol metabolism, characterized by congenital malformations, dysmorphism of multiple organs, mental retardation and delayed neuropsychomotor development resulting from cholesterol biosynthesis deficiency. A defect in 3ß-hydroxysteroid-delta7-reductase (delta7-sterol-reductase, responsible for the conversion of 7-dehydrocholesterol (7-DHC to cholesterol, causes an increase in 7-DHC and frequently reduces plasma cholesterol levels. The clinical diagnosis of SLOS cannot always be conclusive because of the remarkable variability of clinical expression of the disorder. Thus, confirmation by the measurement of plasma 7-DHC levels is needed. In the present study, we used a simple, fast, and selective method based on ultraviolet spectrophotometry to measure 7-DHC in order to diagnose SLOS. 7-DHC was extracted serially from 200 µl plasma with ethanol and n-hexane and the absorbance at 234 and 282 nm was determined. The method was applied to negative control plasma samples from 23 normal individuals and from 6 cases of suspected SLOS. The method was adequate and reliable and 2 SLOS cases were diagnosed.

  1. Using UHPLC and UV-vis Fingerprint Method to Evaluate Substitutes for Swertia mileensis: An Endangered Medicinal Plant.

    Science.gov (United States)

    Li, Jie; Zhang, Ji; Jin, Hang; Wang, Yuan-Zhong; Huang, Heng-Yu

    2017-01-01

    exist are in leaves of S. davidii with the highest content.The obvious diversity in four plants was displayed from comprehensive point of view though similarity assay and PCA analysis.The UV fingerprint method offsets the defect that the UHPLC fingerprint reflected messages of secoiridoid glycosides only. Abbreviation used: UHPLC: Ultra high performance liquid chromatography, UV-vis: Ultraviolet-vis, HBV: Anti-hepatitis virus, DNA: Deoxyribonucleic acid, PCA: Principal component analysis, D-GaIN: D-Galactosamine, BCG: Bacille Calmette-Guerin, LPS: Lipopolysaccharide.

  2. A Simple, Fast, Low Cost, HPLC/UV Validated Method for Determination of Flutamide: Application to Protein Binding Studies.

    Science.gov (United States)

    Esmaeilzadeh, Sara; Valizadeh, Hadi; Zakeri-Milani, Parvin

    2016-06-01

    The main goal of this study was development of a reverse phase high performance liquid chromatography (RP-HPLC) method for flutamide quantitation which is applicable to protein binding studies. Ultrafilteration method was used for protein binding study of flutamide. For sample analysis, flutamide was extracted by a simple and low cost extraction method using diethyl ether and then was determined by HPLC/UV. Acetanilide was used as an internal standard. The chromatographic system consisted of a reversed-phase C8 column with C8 pre-column, and the mobile phase of a mixture of 29% (v/v) methanol, 38% (v/v) acetonitrile and 33% (v/v) potassium dihydrogen phosphate buffer (50 mM) with pH adjusted to 3.2. Acetanilide and flutamide were eluted at 1.8 and 2.9 min, respectively. The linearity of method was confirmed in the range of 62.5-16000 ng/ml (r(2) > 0.99). The limit of quantification was shown to be 62.5 ng/ml. Precision and accuracy ranges found to be (0.2-1.4%, 90-105%) and (0.2-5.3 %, 86.7-98.5 %) respectively. Acetanilide and flutamide capacity factor values of 1.35 and 2.87, tailing factor values of 1.24 and 1.07 and resolution values of 1.8 and 3.22 were obtained in accordance with ICH guidelines. Based on the obtained results a rapid, precise, accurate, sensitive and cost-effective analysis procedure was proposed for quantitative determination of flutamide.

  3. Determination of macro nickel, vanadium and iron in crude oil and residues by derivative spectrophotometry

    International Nuclear Information System (INIS)

    Liu, W.; Wang, L.; Li, X.

    1992-01-01

    In this paper, a new method with derivative spectrophotometry and 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol as the chromogenic reagent in buffer solution of different pH developed for determining micro amounts of nickel. Vanadium and iron in crude oil and residues is reported. Forth-, Second- and Third-, Fourth-order derivative spectrophotometry were applied to determine nickel, nickel and vanadium, nickel and iron in crude oil and residues, respectively. The derivative maximums chosen for the measurement were at 556 nm for nickel, 540 nm and 643 nm for nickel and vanadium, 524 nm and 604 nm for nickel and iron. Beer's law is valid for the range 1.0 x 10 -6 to 2.5 x 10 -5 M

  4. Rapid and Sensitive Determination of Lipid Oxidation Using the Reagent Kit Based on Spectrophotometry (FOODLABfat System

    Directory of Open Access Journals (Sweden)

    Chang Woo Kwon

    2016-01-01

    Full Text Available The reliability and availability of FOODLABfat system for determining acid value (AV and peroxide value (POV were assessed during the hydrolytic rancidification and lipid oxidation of edible oils. This reagent kit based on spectrophotometry was compared to the official methods (ISO 660 and 3960 protocols based on manual titration employing the standard mixture for the simulated oxidation models and edible oils during the thermally induced oxidation at 180°C. The linear regression line of standard mixture and the significant difference of thermally oxidized time course study determined between them showed high correlations (R2=0.998 and p<0.05 in both AVs and POVs. Considering ISO protocols with a probability of human error in manual titration, the rapidness and simplicity of the reagent kit based on spectrophotometry make it a promising alternative to monitor the lipid oxidation of edible oils and lipid-containing foods.

  5. UV irradiation of track membranes as a method for obtaining the necessary value of brittleness for good fractures of samples for sem observations

    International Nuclear Information System (INIS)

    Sartowska, B.; Nowicki, A.; Orelovitch, O.; )

    2006-01-01

    Synthesis of nano- and microstructures of materials inside the pores of specific template-track membranes can be used to obtain nano- and microwires or nano- and microtubes. It is important for these applications to know the inner geometry of the pores like sizes, shape and surface morphology. Scanning electron microscopy technique (SEM) was used predominantly for this kind of membrane characterisation. The use of other methods of sample preparation as electron, gamma rays or UV irradiation allows to make them more brittle. In present paper authors describe preliminary results of the tensile measurements of membranes after UV irradiation. Poly(ethylene terephthalate) (PET) membrane 10 μm thick with pore diameter 1.0 μm were prepared t the Joint Institute for Nuclear Research (Dubna, Russia) using the standard procedure. The samples were irradiated with UV light with energy flux 2.8 W/cm 2 during different periods of time. The tensile measurements of the initial and irradiated materials were carried in the Institute of Nuclear Chemistry and Technology (Warsaw, Poland). In conclusion, authors claim that it is possible to find the dose of UV irradiation that ensures the fracture without elastic deformation. In the case when the time of UV irradiation increases up to 90 h, the PET membrane breaks without distortion of its channel structure

  6. Quantitative determination of curcuminoids from the Roots of Curcuma longa, Curcuma species and dietary supplements using an UPLC-UV-MS method

    Science.gov (United States)

    A simple, fast UPLC-UV-MS method was developed for the determination of curcuminoids from roots of Curcuma longa L., Curcuma species (C. zedoaria, C. phaecaulis, C. wenyujin and C. kwangsiensis) and dietary supplements claiming to contain C. longa. The total content of curcuminoids (curcumin, desmet...

  7. Development and validation of RP-HPLC and UV-spectrophotometric methods for rapid simultaneous estimation of amlodipine and benazepril in pure and fixed dose combination

    Directory of Open Access Journals (Sweden)

    Abhi Kavathia

    2017-05-01

    Full Text Available High-performance liquid chromatographic (HPLC and UV spectrophotometric methods were developed and validated for the quantitative determination of amlodipine besylate (AM and benazepril hydrochloride (BZ. Different analytical performance parameters such as linearity, precision, accuracy, specificity, limit of detection (LOD and limit of quantification (LOQ were determined according to International Conference on Harmonization ICH Q2B guidelines. The RP-HPLC method was developed by the isocratic technique on a reversed-phase Shodex C-18 5e column. The retention time for AM and BZ was 4.43 min and 5.70 min respectively. The UV spectrophotometric determinations were performed at 237 nm and 366 nm for AM and at 237 nm for BZ. Correlation between absorbance of AM at 237 nm and 366 nm was established and based on developed correlation equation estimation of BZ at 237 nm was carried out. The linearity of the calibration curves for each analyte in the desired concentration range was good (r2 > 0.999 by both the HPLC and UV methods. The method showed good reproducibility and recovery with percent relative standard deviation less than 5%. Moreover, the accuracy and precision obtained with HPLC co-related well with the UV method which implied that UV spectroscopy can be a cheap, reliable and less time consuming alternative for chromatographic analysis. The proposed methods are highly sensitive, precise and accurate and hence successfully applied for determining the assay and in vitro dissolution of a marketed formulation.

  8. A comparison of hair colour measurement by digital image analysis with reflective spectrophotometry.

    Science.gov (United States)

    Vaughn, Michelle R; van Oorschot, Roland A H; Baindur-Hudson, Swati

    2009-01-10

    While reflective spectrophotometry is an established method for measuring macroscopic hair colour, it can be cumbersome to use on a large number of individuals and not all reflective spectrophotometry instruments are easily portable. This study investigates the use of digital photographs to measure hair colour and compares its use to reflective spectrophotometry. An understanding of the accuracy of colour determination by these methods is of relevance when undertaking specific investigations, such as those on the genetics of hair colour. Measurements of hair colour may also be of assistance in cases where a photograph is the only evidence of hair colour available (e.g. surveillance). Using the CIE L(*)a(*)b(*) colour space, the hair colour of 134 individuals of European ancestry was measured by both reflective spectrophotometry and by digital image analysis (in V++). A moderate correlation was found along all three colour axes, with Pearson correlation coefficients of 0.625, 0.593 and 0.513 for L(*), a(*) and b(*) respectively (p-values=0.000), with means being significantly overestimated by digital image analysis for all three colour components (by an average of 33.42, 3.38 and 8.00 for L(*), a(*) and b(*) respectively). When using digital image data to group individuals into clusters previously determined by reflective spectrophotometric analysis using a discriminant analysis, individuals were classified into the correct clusters 85.8% of the time when there were two clusters. The percentage of cases correctly classified decreases as the number of clusters increases. It is concluded that, although more convenient, hair colour measurement from digital images has limited use in situations requiring accurate and consistent measurements.

  9. Removal of organic compounds from wastewater originating from the production of printed circuit boards by UV-Fenton method

    Directory of Open Access Journals (Sweden)

    Thomas Maciej

    2017-12-01

    Full Text Available The possibility of removing organic compounds from wastewater originating from the photochemical production of printed circuit boards by use of waste acidification and disposal of precipitated photopolymer in the first stage and the UV-Fenton method in a second stage has been presented. To optimize the process of advanced oxidation, the RSM (Response Surface Methodology for three independent factors was applied, i.e. pH, the concentration of Fe(II and H2O2 concentration. The use of optimized values of individual parameters in the process of wastewater treatment caused a decrease in the concentration of the organic compounds denoted as COD by approx. 87% in the first stage and approx. 98% after application of both processes. Precipitation and the decomposition of organic compounds was associated with a decrease of wastewater COD to below 100 mg O2/L whereas the initial value was 5550 mg O2/L. Decomposition of organic compounds and verification of the developed model of photopolymers removal was also carried out with use of alternative H2O2 sources i.e. CaO2, MgO2, and Na2CO3·1,5H2O2.

  10. Chlorine Dioxide-Iodide-Methyl Acetoacetate Oscillation Reaction Investigated by UV-Vis and Online FTIR Spectrophotometric Method

    Directory of Open Access Journals (Sweden)

    Laishun Shi

    2012-01-01

    Full Text Available In order to study the chemical oscillatory behavior and mechanism of a new chlorine dioxide-iodide ion-methyl acetoacetate reaction system, a series of experiments were done by using UV-Vis and online FTIR spectrophotometric method. The initial concentrations of methyl acetoacetate, chlorine dioxide, potassium iodide, and sulfuric acid and the pH value have great influence on the oscillation observed at wavelength of 289 nm. There is a preoscillatory or induction period, and the amplitude and the number of oscillations are associated with the initial concentration of reactants. The equations for the triiodide ion reaction rate changing with reaction time and the initial concentrations in the oscillation stage were obtained. Oscillation reaction can be accelerated by increasing temperature. The apparent activation energies in terms of the induction period and the oscillation period were 26.02 KJ/mol and 17.65 KJ/mol, respectively. The intermediates were detected by the online FTIR analysis. Based upon the experimental data in this work and in the literature, a plausible reaction mechanism was proposed for the oscillation reaction.

  11. Ultraviolet spectrophotometry of comet Giacobini-Zinner during the ICE encounter. [International Cometary Explorer (ICE)

    Science.gov (United States)

    Ahearn, Michael F.; Mcfadden, Lucy A.; Feldman, Paul D.; Boehnhardt, Hermann; Rahe, Juergen; Festou, Michael; Brandt, John C.; Maran, Stephen P.; Niedner, Malcom B.; Smith, Andrew M.

    1986-01-01

    The IUE spectrophotometry of Comet P/Giacobini-Zinner was acquired in support of the International Cometary Explorer (ICE) mission. The abundances (or upper limits) of UV-active species were calculated. During the ICE encounter the H2O production rate was 3 times 10 to the 28th power/sec, + or - 50%, consistent with values derived from the ICE experiments. Comparison of the abundance of CO2(+) ions with the total electron density measured by the plasma electron experiment on ICE indicates a deficiency of ions relative to electrons indicating a population of ions not detected by remote sensing. The absence of detectable Mg(+) rules out this species as a possible ion of M/Q = 24 detected by the Ion Composition Instrument, part of the ICE complement of instruments.

  12. Comparison of UV-Curing, Hotmelt, and Pressure Sensitive Adhesive as Roll-to-Roll Encapsulation Methods for Polymer Solar Cells

    DEFF Research Database (Denmark)

    Hösel, Markus; Søndergaard, Roar R.; Jørgensen, Mikkel

    2013-01-01

    The most distinct advantage of the polymer solar cell is the possibility for roll-to-roll (R2R) fabrication compatibility based on printing and coating processes. The R2R encapsulation is the last crucial process step in the manufacturing workflow and is evaluated in this study. Polymer solar cell...... modules are directly printed on barrier foil and encapsulated with the same barrier foil either on the backside or on both sides of the device. The three lamination methods comprise of UV-curable epoxy resin, hotmelt, and pressure sensitive adhesive (PSA). It is shown that a single sided encapsulation...... of the PSA method is the fastest method (in this study) it generates a considerable amount of waste (paper liner) and two lamination steps are required to achieve a sufficient lifetime. We conclude that UV-curing presents the largest advantages of all methods with a good upscaling potential and low embodied...

  13. The role of spectrophotometry in the diagnosis of melanoma

    Science.gov (United States)

    2010-01-01

    Background Spectrophotometry (SPT) could represent a promising technique for the diagnosis of cutaneous melanoma (CM) at earlier stages of the disease. Starting from our experience, we further assessed the role of SPT in CM early detection. Methods During a health campaign for malignant melanoma at National Cancer Institute of Naples, we identified a subset of 54 lesions to be addressed to surgical excision and histological examination. Before surgery, all patients were investigated by clinical and epiluminescence microscopy (ELM) screenings; selected lesions underwent spectrophotometer analysis. For SPT, we used a video spectrophotometer imaging system (Spectroshade® MHT S.p.A., Verona, Italy). Results Among the 54 patients harbouring cutaneous pigmented lesions, we performed comparison between results from the SPT screening and the histological diagnoses as well as evaluation of both sensitivity and specificity in detecting CM using either SPT or conventional approaches. For all pigmented lesions, agreement between histology and SPT classification was 57.4%. The sensitivity and specificity of SPT in detecting melanoma were 66.6% and 76.2%, respectively. Conclusions Although SPT is still considered as a valuable diagnostic tool for CM, its low accuracy, sensitivity, and specificity represent the main hamper for the introduction of such a methodology in clinical practice. Dermoscopy remains the best diagnostic tool for the preoperative diagnosis of pigmented skin lesions. PMID:20707921

  14. [Wavelength Selection in Hemolytic Evaluation Systems with Spectrophotometry Detection].

    Science.gov (United States)

    Zhang, Hong; Su, Baochang; Ye, Xunda; Luo, Man

    2016-04-01

    Spectrophotometry is a simple hemolytic evaluation method commonly used in new drugs,biomedical materials and blood products.It is for the quantitative analysis of the characteristic absorption peaks of hemoglobin.Therefore,it is essential to select the correct detection wavelength when the evaluation system has influences on the conformation of hemoglobin.Based on the study of changes in the characteristic peaks over time of the hemolysis supernatant in four systems,namely,cell culture medium,phosphate buffered saline(PBS),physiological saline and banked blood preservation solution,using continuous wavelength scanning,the selections of detection wavelength were proposed as follows.In the cell culture medium system,the wavelength of 415 nm should be selected within 4h;,near 408 nm should be selected within 4~72h.In PBS system,within 4h,541 nm,577nm or 415 nm should be selected;4~72h,541 nm,577nm or near 406 nm should be selected.In physiological saline system,within 4h,414 nm should be selected;4~72h,near 405 nm should be selected;within 12 h,541nm or 577 nm could also be selected.In banked blood preservation solution system,within 72 h,415nm,540 nm or 576 nm should be selected.

  15. Determination of molybdenum in flotation concentrates by atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Ise, Kazuo

    1978-01-01

    Molybdenum was determined by atomic absorption spectrophotometry in 0.05 N ammoniacal solution after the decomposition of the concentrate with aqua regia. Negros ore from Philippines was used as a flotation feed, which contained chalcopyrites and calcium-magnesium minerals. Among the metals tested copper, iron and the alkaline earths interfered. Less than 50 ppm of copper yielded lower results for molybdenum. Higher results came out with more than 50 ppm of copper. In the presence of iron and citric acid (0.4 g/100 ml) which is a suppressor for hydroxide formation, a lower estimation resulted for molybdenum. Calcium interfered, lower results by 2 and >10% being obtained with respective 2.5 and 20 ppm of calcium. More than 20 ppm of magnesium behaved similarly. Sodium sulfate (0.5 g/100 ml) served as the suppressor for copper, iron and citric acid; 100 ppm each of copper and iron did not interfere in this way. Interferences due to calcium and magnesium (less than 60 ppm) was able to be masked by the addition of sodium silicate (200 ppm as silica). The analysis of flotation products and synthetic samples consisting of molybdenite, chalcopyrite, calcium chloride and magnesium sulfate revealed that the atomic absorption method can be applied to the analysis of the concentrates for molybdenum with an error of about 2%. (auth.)

  16. Development, validation and comparison of two stability-indicating RP-LC methods using charged aerosol and UV detectors for analysis of lisdexamfetamine dimesylate in capsules

    Directory of Open Access Journals (Sweden)

    Graciela Carlos

    2016-11-01

    Full Text Available Two new stability-indicating liquid chromatographic methods using two detectors, an ultraviolet (UV and a charged aerosol detector (CAD simultaneously connected in series were validated for the assessment of lisdexamfetamine dimesylate (LDX in capsule. The method was optimized and the influence of individual parameters on UV and CAD response and sensitivity was studied. Chromatography was performed on a Zorbax CN column (250 mm × 4.6 mm, 5 μm in an isocratic elution mode, using acetonitrile and 20 mM ammonium formate at pH 4.0 (50:50, v/v as mobile phase and UV detection at 207 nm. The developed method was validated according to ICH guidelines and the parameters’ specificity, limit of detection, limit of quantitation, linearity, accuracy, precision and robustness were evaluated. CAD is designated to be a non-linear detector in a wide dynamic range, however, the method was linear over the concentration range of 70–130 μg mL−1 in both detectors. The method was precise and accurate. Robustness study was performed by a Plackett–Burman design, delivering results within the acceptable range. Neither the excipients nor the degradation products showed interference in the method after studies of specificity as well as under stress conditions. The results of the LC-UV and LC-CAD methods were statistically compared through ANOVA and showed no significant difference (p > 0.05. Both proposed methods could be considered interchangeable and stability-indicating, and can be applied as an appropriate quality control tool for routine analysis of LDX in capsule.

  17. A platform analytical quality by design (AQbD) approach for multiple UHPLC-UV and UHPLC-MS methods development for protein analysis.

    Science.gov (United States)

    Kochling, Jianmei; Wu, Wei; Hua, Yimin; Guan, Qian; Castaneda-Merced, Juan

    2016-06-05

    A platform analytical quality by design approach for methods development is presented in this paper. This approach is not limited just to method development following the same logical Analytical quality by design (AQbD) process, it is also exploited across a range of applications in methods development with commonality in equipment and procedures. As demonstrated by the development process of 3 methods, the systematic approach strategy offers a thorough understanding of the method scientific strength. The knowledge gained from the UHPLC-UV peptide mapping method can be easily transferred to the UHPLC-MS oxidation method and the UHPLC-UV C-terminal heterogeneity methods of the same protein. In addition, the platform AQbD method development strategy ensures method robustness is built in during development. In early phases, a good method can generate reliable data for product development allowing confident decision making. Methods generated following the AQbD approach have great potential for avoiding extensive post-approval analytical method change. While in the commercial phase, high quality data ensures timely data release, reduced regulatory risk, and lowered lab operational cost. Moreover, large, reliable database and knowledge gained during AQbD method development provide strong justifications during regulatory filling for the selection of important parameters or parameter change needs for method validation, and help to justify for removal of unnecessary tests used for product specifications. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. An effective method of UV-oxidation of dissolved organic carbon in natural waters for radiocarbon analysis by accelerator mass spectrometry

    Science.gov (United States)

    Xue, Yuejun; Ge, Tiantian; Wang, Xuchen

    2015-12-01

    Radiocarbon (14C) measurement of dissolved organic carbon (DOC) is a very powerful tool to study the sources, transformation and cycling of carbon in the ocean. The technique, however, remains great challenges for complete and successful oxidation of sufficient DOC with low blanks for high precision carbon isotopic ratio analysis, largely due to the overwhelming proportion of salts and low DOC concentrations in the ocean. In this paper, we report an effective UV-Oxidation method for oxidizing DOC in natural waters for radiocarbon analysis by accelerator mass spectrometry (AMS). The UV-oxidation system and method show 95%±4% oxidation efficiency and high reproducibility for DOC in both river and seawater samples. The blanks associated with the method was also low (about 3 µg C) that is critical for 14C analysis. As a great advantage of the method, multiple water samples can be oxidized at the same time so it reduces the sample processing time substantially compared with other UV-oxidation method currently being used in other laboratories. We have used the system and method for 14C studies of DOC in rivers, estuaries, and oceanic environments and have received promise results.

  19. Comparison of two novel in-syringe dispersive liquid-liquid microextraction techniques for the determination of iodide in water samples using spectrophotometry.

    Science.gov (United States)

    Kaykhaii, Massoud; Sargazi, Mona

    2014-01-01

    Two new, rapid methodologies have been developed and applied successfully for the determination of trace levels of iodide in real water samples. Both techniques are based on a combination of in-syringe dispersive liquid-liquid microextraction (IS-DLLME) and micro-volume UV-Vis spectrophotometry. In the first technique, iodide is oxidized with nitrous acid to the colorless anion of ICl2(-) at high concentration of hydrochloric acid. Rhodamine B is added and by means of one step IS-DLLME, the ion-pair formed was extracted into toluene and measured spectrophotometrically. Acetone is used as dispersive solvent. The second method is based on the IS-DLLME microextraction of iodide as iodide/1, 10-phenanthroline-iron((II)) chelate cation ion-pair (colored) into nitrobenzene. Methanol was selected as dispersive solvent. Optimal conditions for iodide extraction were determined for both approaches. Methods are compared in terms of analytical parameters such as precision, accuracy, speed and limit of detection. Both methods were successfully applied to determining iodide in tap and river water samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Biosythesis of Silver Nanoparticles using Putri Malu (Mimosa pudica Leaves Extract and Microwave Irradiation Method

    Directory of Open Access Journals (Sweden)

    Is Fatimah

    2016-11-01

    Full Text Available In this paper, the biosynthesis of silver nanoparticles (AgNPs using Mimosa pudica extract is discussed. Mimosa pudica leaves extract using water as solvent was used as bio-reductor to an aqueous solution of silver nitrate (AgNO3 and in order to accelerate the reduction, microwave irradiation method was applied. The AgNPs obtained were characterized using UV-Vis spectrophotometry, FTIR spectrophotometry, XRD, SEM-EDX, and particle size analysis based on dynamic scattering method. Effect of preparation method to the formation of AgNPs is also evaluated in antibacterial activity towards E.coli and P. aeruginosa. Rapid and ecofriendly biosynthesis of stable silver nanoparticles was observed in this study. The characterization results and antibacterial assay indicated the uniform and smaller particle size of AgNPs obtained by using microwave method and positively enhance the antibacterial activity against tested bacteria.

  1. Effect of flavin compounds on uranium(VI) reduction- kinetic study using electrochemical methods with UV-vis spectroscopy

    International Nuclear Information System (INIS)

    Yamasaki, Shinya; Tanaka, Kazuya; Kozai, Naofumi; Ohnuki, Toshihiko

    2017-01-01

    The reduction of uranium hexavalent (U(VI)) to tetravalent (U(IV)) is an important reaction because of the change in its mobility in the natural environment. Although the flavin mononucleotide (FMN) has acted as an electron shuttle for the U(VI) reduction in vivo system, which is called an electron mediator, only the rate constant for the electron transfer from FMN to U(VI) has been determined. This study examined the rate constant for the U(VI) reduction process by three flavin analogues (riboflavin, flavin mononucleotide, flavin adenine dinucleotide) to elucidate their substituent group effect on the U(VI) reduction rate by electrochemical methods. The formation of the U(IV) was monitored by UV-vis spectrometry at 660 nm during the constant potential electrolysis of the U(VI) solution in the presence of the mediator. The cyclic voltammograms indicated that the three flavin analogues behaved as electron mediator to reduce U(VI). The logarithmic rate constant for the U(VI) reduction was related to the standard redox potential of the mediators. This linear relationship indicated that the redox-active group of the mediator and the substituent group of the mediator dominate capability of the U(VI) reduction and its rate, respectively. The apparent reduction potential of U(VI) increased about 0.2 V in the presence of the mediators, which strongly suggests that the biological electron mediator makes the U(VI) reduction possible even under more oxidative conditions. - Highlights: • The rate constant for the U(VI) reduction by flavin analogues was determined. • The flavins showed a mediator effect on the U(VI) reduction. • The logarithmic rate constants for the U(VI) reduction was proportional to redox potential of the mediator. • The presence of the mediator increased about 0.2 V apparent redox potential of U(VI) to U(IV).

  2. Synthesis of Graphene-CdSe Composite by a Simple Hydrothermal Method and Its Photocatalytic Degradation of Organic Dyes

    Institute of Scientific and Technical Information of China (English)

    OH Won-Chun; CHEN Mingliang; CHO Kwangyoun; KIM Cheolkyu; MENG Zeda; ZHULei

    2011-01-01

    A graphene-CdSe composite was synthesized by a facile hydrothermal method,and characterized by X-ray diffiraction,scanning electron microscopy with energy dispersive X-ray analysis,transmission electron microscopy and UV-vis diffuse reflectance spectrophotometry.The graphene-CdSe composite efficiently catalyzed the photodegradation of methylene blue (MB),methyl orange (MO) and rhodamine B (Rh.B) in aqueous solution under UV or visible light irradiation.The graphene-CdSe composite exhibited a higher photocatalytic activity for the MB solution.

  3. Microwave Synthesized ZnO Nanorod Arrays for UV Sensors: A Seed Layer Annealing Temperature Study.

    Science.gov (United States)

    Pimentel, Ana; Ferreira, Sofia Henriques; Nunes, Daniela; Calmeiro, Tomas; Martins, Rodrigo; Fortunato, Elvira

    2016-04-20

    The present work reports the influence of zinc oxide (ZnO) seed layer annealing temperature on structural, optical and electrical properties of ZnO nanorod arrays, synthesized by hydrothermal method assisted by microwave radiation, to be used as UV sensors. The ZnO seed layer was produced using the spin-coating method and several annealing temperatures, ranging from 100 to 500 °C, have been tested. X-ray diffraction (XRD), scanning electron microscopy (SEM), atomic force microscopy (AFM) and spectrophotometry measurements have been used to investigate the structure, morphology, and optical properties variations of the produced ZnO nanorod arrays regarding the seed layer annealing temperatures employed. After the growth of ZnO nanorod arrays, the whole structure was tested as UV sensors, showing an increase in the sensitivity with the increase of seed layer annealing temperature. The UV sensor response of ZnO nanorod arrays produced with the seed layer annealed temperature of 500 °C was 50 times superior to the ones produced with a seed layer annealed at 100 °C.

  4. Near-simultaneous optical and infrared spectrophotometry of active galaxies

    International Nuclear Information System (INIS)

    Yates, M.G.; Garden, R.P.

    1989-01-01

    We present optical and infrared spectrophotometry for a sample of eight optically bright quasars, and the broad-line radio galaxy (BLRG) 3C 120. The optical and infrared spectrophotometry is separated by only five weeks, thus we have been able to minimize uncertainties due to variations in the objects. We compare our observed Paα/Hα and Hα/Hβ ratios with a large number of current photoionization models. We find that none of these models are able to reproduce our observed values of Paα/Hα in any of the active galaxies except the quasars 3C 273 and 0736+017. (author)

  5. Far-ultraviolet spectrophotometry of Spica

    Science.gov (United States)

    Cook, Timothy A.; Cash, Webster; Snow, Theodore P.

    1989-01-01

    A spectrum of the star Spica (Alpha Virginis) from 960 to 1270 A was recorded by a rocket-borne spectrograph March 13, 1988. The spectrum, which has 3.4 A resolution, shows a much sharper drop-off in intensity near 1050 A than similar measurements made by the Voyager UVS, but is in good agreement with the spectrum obtained by Brune et al. in a 1977 sounding rocket. The disagreement with Voyager is a factor of 1.5 at 1100 A and grows to a factor of 5.7 at 960 A. This implies that the photometric standards between 912 and 1100 A may need some revision, and that the standard photospheric models for hot stars may err significantly near the Lyman limit.

  6. Qualitative and quantitative determination of yohimbine in authentic yohimbe bark and in commercial aphrodisiacs by HPLC-UV-API/ MS methods.

    Science.gov (United States)

    Zanolari, Boris; Ndjoko, Karine; Ioset, Jean-Robert; Marston, Andrew; Hostettmann, Kurt

    2003-01-01

    The development and validation of a rapid qualitative and quantitative method based on an HPLC-UV-MS technique with atmospheric pressure chemical ionisation and electrospray ionisation for the analysis of yohimbine in a number of commercial aphrodisiac products is reported. HPLC with multiple-stage mass spectrometry experiments allowed the identification of the target compound and increased the selectivity of complex analyses such as those involved with multi-botanical preparations. The precision and the robustness of the method were improved by the use of two internal standards: codeine for UV detection and deuterium-labelled yohimbine for MS detection. Twenty commercial aphrodisiac preparations were analysed and the amount of yohimbine measured and expressed as the maximal dose per day suggested on product labels ranged from 1.32 to 23.16 mg.

  7. Využití UV/VIS spektrofotometrie pro stanovení diklofenaku

    Czech Academy of Sciences Publication Activity Database

    Čapka, Lukáš; Zlámalová Gargošová, H.; Vávrová, M.; Urbánková, L.

    2013-01-01

    Roč. 107, č. 7 (2013), s. 550-554 ISSN 0009-2770 Institutional support: RVO:68081715 Keywords : diclofenac * UV-VIS spectrophotometry * environment * fate * pharmaceutical residues Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 0.196, year: 2013

  8. Determination of traces of silver in waters by anion exchange and atomic absorption spectrophotometry

    Science.gov (United States)

    Chao, T.T.; Fishman, M. J.; Ball, J.W.

    1969-01-01

    A method has been developed for the accurate determination of 0.1-1 ??g of silver per liter of water. The method permits stabilization of silver in water without loss to container walls. Optimum conditions have been established for the complete recovery of silver from water with an anion-exchange column, for quantitative elution of silver from the resin, and for measurement of silver by atomic absorption spectrophotometry after chelation with ammonium pyrrolidine dithiocarbamate and extraction of the chelate with MIBK. Silver in the 1-10 ??g 1 range can be determined by extraction without pre-concentration on an ion-exchange resin. ?? 1969.

  9. A new signal restoration method based on deconvolution of the Point Spread Function (PSF) for the Flat-Field Holographic Concave Grating UV spectrometer system

    Science.gov (United States)

    Dai, Honglin; Luo, Yongdao

    2013-12-01

    In recent years, with the development of the Flat-Field Holographic Concave Grating, they are adopted by all kinds of UV spectrometers. By means of single optical surface, the Flat-Field Holographic Concave Grating can implement dispersion and imaging that make the UV spectrometer system design quite compact. However, the calibration of the Flat-Field Holographic Concave Grating is very difficult. Various factors make its imaging quality difficult to be guaranteed. So we have to process the spectrum signal with signal restoration before using it. Guiding by the theory of signals and systems, and after a series of experiments, we found that our UV spectrometer system is a Linear Space- Variant System. It means that we have to measure PSF of every pixel of the system which contains thousands of pixels. Obviously, that's a large amount of calculation .For dealing with this problem, we proposes a novel signal restoration method. This method divides the system into several Linear Space-Invariant subsystems and then makes signal restoration with PSFs. Our experiments turn out that this method is effective and inexpensive.

  10. Fourier transform infrared spectrophotometry and X-ray powder ...

    African Journals Online (AJOL)

    This study aimed at demonstrating complementary roles offered by both Fourier transform infrared (FTIR) spectrophotometry and x-ray powder diffraction (XRPD) techniques in characterizing clay size fraction of kaolins. The clay size fraction of kaolin samples obtained from Kgwakgwe, Makoro, Lobatse and Serule kaolin ...

  11. An important improvement in Ferron-timed spectrophotometry

    NARCIS (Netherlands)

    Zhang, Jing; Chang, Fang; Ren, Yijin; Shi, Qiuyi

    Ferron dosage ([Ferron]) is key to ferron-timed spectrophotometry (ferron assay). In order to clarify some important questions, the following studies were conducted: (1) The effect of [Ferron] on the sensitivity of total aluminum (AlT) determination was experimentally investigated and ²⁷Al nuclear

  12. A Computer-aided Learning Exercise in Spectrophotometry.

    Science.gov (United States)

    Pamula, Frederick

    1994-01-01

    Discusses the use of a computer simulation program in teaching the concepts of spectrophotometry. Introduces several parts of the program and program usage. Presents an assessment activity to evaluate students' mastery of material. Concludes with the advantages of this approach to the student and to the assessor. (ASK)

  13. Spectrophotometry of CRL 2688 from 2 to 24 microns

    International Nuclear Information System (INIS)

    Forrest, W.J.; Merrill, K.M.; Russell, R.W.; Soifer, B.T.

    1975-01-01

    Medium-resolution spectrophotometry (Δlambda/lambdaapprox. =0.01) of CRL 2688 from 2 μ to 24 μ are reported. No significant features are found from 3 μ to 24 μ, although the spectral flux distribution is broader than that of a single-temperature blackbody

  14. Spectrophotometry of four galaxies of high surface brightness

    International Nuclear Information System (INIS)

    Arakelyan, M.A.; Magtesyan, A.P.

    1982-01-01

    Spectrophotometry has been performed for the emission lines in the nuclei of Arakelyan galaxies Nos. 428, 449, 454, 532. In the first two objects, H II clouds occur roughly-equal2 kpc out from the nucleus. No. 449 may contain another cloud moving at roughly-equal1500 km/sec radial velocity. radial

  15. The determination of zirconium by atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Rodriguez, E.R.; Cunha, M.T.C. da

    1975-01-01

    The interference of iron in the determination of zirconium by atomic absorption spectrophotometry was studied. Attempts were made to emininate this interference by complexing the iron with EDTA, ascorbic acid and hydrazine; also by the addition of ammonium fluoride to the solution. Some experiments were carried out in order to explain the results obtained [pt

  16. Applied spectrophotometry: analysis of a biochemical mixture.

    Science.gov (United States)

    Trumbo, Toni A; Schultz, Emeric; Borland, Michael G; Pugh, Michael Eugene

    2013-01-01

    Spectrophotometric analysis is essential for determining biomolecule concentration of a solution and is employed ubiquitously in biochemistry and molecular biology. The application of the Beer-Lambert-Bouguer Lawis routinely used to determine the concentration of DNA, RNA or protein. There is however a significant difference in determining the concentration of a given species (RNA, DNA, protein) in isolation (a contrived circumstance) as opposed to determining that concentration in the presence of other species (a more realistic situation). To present the student with a more realistic laboratory experience and also to fill a hole that we believe exists in student experience prior to reaching a biochemistry course, we have devised a three week laboratory experience designed so that students learn to: connect laboratory practice with theory, apply the Beer-Lambert-Bougert Law to biochemical analyses, demonstrate the utility and limitations of example quantitative colorimetric assays, demonstrate the utility and limitations of UV analyses for biomolecules, develop strategies for analysis of a solution of unknown biomolecular composition, use digital micropipettors to make accurate and precise measurements, and apply graphing software. Copyright © 2013 Wiley Periodicals, Inc.

  17. Chemometrics-Assisted UV Spectrophotometric and RP-HPLC Methods for the Simultaneous Determination of Tolperisone Hydrochloride and Diclofenac Sodium in their Combined Pharmaceutical Formulation.

    Science.gov (United States)

    Gohel, Nikunj Rameshbhai; Patel, Bhavin Kiritbhai; Parmar, Vijaykumar Kunvarji

    2013-01-01

    Chemometrics-assisted UV spectrophotometric and RP-HPLC methods are presented for the simultaneous determination of tolperisone hydrochloride (TOL) and diclofenac sodium (DIC) from their combined pharmaceutical dosage form. Chemometric methods are based on principal component regression and partial least-square regression models. Two sets of standard mixtures, calibration sets, and validation sets were prepared. Both models were optimized to quantify each drug in the mixture using the information included in the UV absorption spectra of the appropriate solution in the range 241-290 nm with the intervals λ = 1 nm at 50 wavelengths. The optimized models were successfully applied to the simultaneous determination of these drugs in synthetic mixture and pharmaceutical formulation. In addition, an HPLC method was developed using a reversed-phase C18 column at ambient temperature with a mobile phase consisting of methanol:acetonitrile:water (60:30:10 v/v/v), pH-adjusted to 3.0, with UV detection at 275 nm. The methods were validated in terms of linearity, accuracy, precision, sensitivity, specificity, and robustness in the range of 3-30 μg/mL for TOL and 1-10 μg/mL for DIC. The robustness of the HPLC method was tested using an experimental design approach. The developed HPLC method, and the PCR and PLS models were used to determine the amount of TOL and DIC in tablets. The data obtained from the PCR and PLS models were not significantly different from those obtained from the HPLC method at 95% confidence limit.

  18. In situ deposition of graphene nanosheets on wood surface by one-pot hydrothermal method for enhanced UV-resistant ability

    International Nuclear Information System (INIS)

    Wan, Caichao; Jiao, Yue; Li, Jian

    2015-01-01

    Graphical abstract: - Highlights: • The graphene/wood nanocomposites were fabricated via a mild fast one-pot hydrothermal method. • Graphene nanosheets were in situ deposited on the surface of the wood matrix. • The incorporation of graphene nanosheets results in the improvement in the thermal stability of the graphene/wood. • The graphene/wood exhibits superior UV resistance performance. - Abstract: Graphene nanosheets were successfully in situ deposited on the surface of the wood matrix via a mild fast one-pot hydrothermal method, and the resulting hybrid graphene/wood (GW) were characterized by scanning electron microscope (SEM), energy dispersive X-ray spectroscopy (EDX), X-ray diffraction (XRD), Raman spectroscopy, and thermogravimetric analysis (TGA). According to the results, the wood matrix was evenly coated by dense uninterrupted multilayer graphene membrane structure, which was formed by layer-by-layer self-assembly of graphene nanosheets. Meanwhile, the graphene coating also induced significant improvement in the thermal stability of GW in comparison with that of the original wood (OW). Accelerated weathering tests were employed to measure and determine the UV-resistant ability of OW and GW. After about six hundred hours of experiments, the surface color change of GW was much less than that of OW; besides, the Fourier transform infrared spectroscopy (FTIR) analysis also proved the less significant changes in surface chemical compositions of GW. The results both indicated that the graphene coating effectively protected wood surface from UV damage. Therefore, this class of GW composite might be expected to be served as high-performance wooden building material for outdoor or some particular harsh environments like strong UV radiation regions use

  19. Fully-differential spectrophotometry determination of trace thorium in uranium-containing waste water separated by CL-TBP levextrel resin

    International Nuclear Information System (INIS)

    You Jiannan

    2000-01-01

    A method for separation by CL-TBP levextrel resin and determination of trace thorium in uranium-containing waste water by fully-differential spectrophotometry is developed. In 4 mol/L HNO 3 medium, in presence of tartaric acid, CL-TBP levextrel resin is used for adsorption of thorium and separating from other elements. The thorium on the resin is stripped by 4 mol/L HCl, with oxalic acid and urea as screening agent, thorium forms red complex with arsenazo III. The maximum absorption of the complex is at 668 nm, and the molar absorptivity is 1.27 x 10 5 L/(mol·cm) . The complex can be steady for 2.5 h. By regulating micro-current of differential spectrophotometry, the method can realize determination with high precision. Sensitivity of this method increase 10 times than usual spectrophotometry. The relative standard deviation is better than +- 5% and recovery of thorium is 99%-107%

  20. Characterization of tannin-metal complexes by UV-visible spectrophotometry

    Science.gov (United States)

    Tannins enter soils by plant decay and rain throughfall, but little is known of their effects on soils. Tannins may influence bioavailability and toxicity of metals by forming complexes and by mediating redox reactions. We evaluated the affinity and stoichiometry of Al(III) for a gallotannin, pent...

  1. Carboxyterfenadine antacid interaction monitoring by UV spectrophotometry and RP-HPLC techniques

    Directory of Open Access Journals (Sweden)

    Hina Shehnaz

    2014-11-01

    Full Text Available Carboxyterfenadine, a primary metabolite of terfenadine, a second generation antihistaminic compound was introduced in therapy as a successor of terfenadine due to its cardiac arrhythmia. There are number of drug interactions of fexofenadine with erythromycin, ketoconazole and alike reported in the literature. In this paper, fexofenadine antacid interaction has been studied in presence of sodium bicarbonate, megaldrate, calcium carbonate, magnesium carbonate, aluminum hydroxide, magnesium hydroxide, magnesium trisilicate, simethicone (dimethylpolysiloxane and calcium hydroxide by UV–Vis spectrophotometer and high performance liquid chromatography (HPLC. These in vitro fexofenadine–antacid interactions were carried out in simulated gastric and intestinal juices and in buffer of pH 7.4 (simulating blood pH on BP 2005 dissolution apparatus. The results show non-concordant availability of fexofenadine envisaged due to formation of unstable charge transfer complexes.

  2. Four Brazilian Maytenus salicifolia Reissek (Celastraceae) groups studied by TLC and UV/Vis spectrophotometry

    OpenAIRE

    Valladão,Frederico N.; Miranda,Roqueline R. S.; Vale,Fernando H.; Valladão,Sara A.; Silva,Grácia D. F.; Duarte,Lucienir P.; Carvalho-Okano,Rita M.; Messias,Maria C. T. B.; Viera Filho,Sidney A.

    2009-01-01

    A grande variedade de angiospermas apontou a necessidade do desenvolvimento de sistemas de classificação botânica apoiada pela fitoquímica, bioquímica e outras. Recentemente, técnicas de análise utilizadas para o isolamento e caracterização de metabólitos secundários vêm sendo empregadas como métodos auxiliares rápidos e eficientes para identificação e classificação de espécies vegetais. M. salicifolia é popularmente conhecida no Brasil, como “cafezinho”. O chá obtido a partir de folhas fresc...

  3. Chemical methods of rock analysis

    National Research Council Canada - National Science Library

    Jeffery, P. G; Hutchison, D

    1981-01-01

    .... Such methods include those based upon spectrophotometry, flame emission spectrometry and atomic absorption spectroscopy, as well as gravimetry, titrimetry and the use of ion-selective electrodes...

  4. Determination of Ca, Cu, Fe and Pb in sugarcane raw spirits by atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Lorenzo, Magdalena; Reyes, Arlyn; Blanco, Idania; Vasallo, Maria C

    2010-01-01

    The determination of Ca, Cu, Fe and Pb in sugarcane raw spirits by atomic absorption spectrophotometry was carried out. For 20 μL injected sample, calibration within the 0,5-25,0 mg. L -1 Ca; 0,25-5,0 mg. L -1 Cu, Pb and Cu intervals were established using the ratios Cu, Ca, Fe and Pb absorbance versus analyte concentration, respectively. Typical linear correlations of r = 0,999 were obtained. The proposed method was applied for the direct determination of Ca, Cu, Fe and Pb in sugar cane spirits, and in samples. The results obtained were in accordance to those obtained at 95% confidence level

  5. Acid-Base Properties of Azo Dyes in Solution Studied Using Spectrophotometry and Colorimetry

    Science.gov (United States)

    Snigur, D. V.; Chebotarev, A. N.; Bevziuk, K. V.

    2018-03-01

    Colorimetry and spectrophotometry with chemometric data processing were used to study the acid-base properties of azo dyes in aqueous solution. The capabilities of both methods were compared. Ionization constants of all the functional groups of the azo compounds studied could be determined relative to the change in the specific color difference depending on the acidity of the medium. The colorimetric functions of ion-molecular forms of azo compounds used as an analytical signal allow us to obtain complete information on the acid-base equilibrium in a wide acidity range.

  6. Determination of silica in silicates by differential spectrophotometry as α-molybdosilicic acid

    International Nuclear Information System (INIS)

    Ohlweiler, O.A.; Meditsch, J.O.; Silva, S.

    1980-01-01

    A method for determining silica in silicates by differential spectrophotometry, using β-molybdosilic acid, is described. The sample is attacked by a mixture of boron trioxide and lithium carbonate (10:1). α-molydbosilicic acid is developed in a buffered solution (pH approximatelly 3.9) containing acetic acid and sodium acetate. The analytical procedure involves a series of preliminary steps which were previously elaborated for the gravimetric determination of silica as oxine molybdosilicate and which account for the removal of phosphorus, titanium and zirconium through ion exchange resins. (C.L.B.) [pt

  7. The quantification of spermatozoa by real-time quantitative PCR, spectrophotometry, and spermatophore cap size.

    Science.gov (United States)

    Doyle, Jacqueline M; McCormick, Cory R; DeWoody, J Andrew

    2011-01-01

    Many animals, such as crustaceans, insects, and salamanders, package their sperm into spermatophores, and the number of spermatozoa contained in a spermatophore is relevant to studies of sexual selection and sperm competition. We used two molecular methods, real-time quantitative polymerase chain reaction (RT-qPCR) and spectrophotometry, to estimate sperm numbers from spermatophores. First, we designed gene-specific primers that produced a single amplicon in four species of ambystomatid salamanders. A standard curve generated from cloned amplicons revealed a strong positive relationship between template DNA quantity and cycle threshold, suggesting that RT-qPCR could be used to quantify sperm in a given sample. We then extracted DNA from multiple Ambystoma maculatum spermatophores, performed RT-qPCR on each sample, and estimated template copy numbers (i.e. sperm number) using the standard curve. Second, we used spectrophotometry to determine the number of sperm per spermatophore by measuring DNA concentration relative to the genome size. We documented a significant positive relationship between the estimates of sperm number based on RT-qPCR and those based on spectrophotometry. When these molecular estimates were compared to spermatophore cap size, which in principle could predict the number of sperm contained in the spermatophore, we also found a significant positive relationship between sperm number and spermatophore cap size. This linear model allows estimates of sperm number strictly from cap size, an approach which could greatly simplify the estimation of sperm number in future studies. These methods may help explain variation in fertilization success where sperm competition is mediated by sperm quantity. © 2010 Blackwell Publishing Ltd.

  8. An efficient visible and UV-light-activated B-N-codoped TiO{sub 2} photocatalytic film for solar depollution prepared via a green method

    Energy Technology Data Exchange (ETDEWEB)

    Xu Qingchi; Zhang Yan; He Ziming [Nanyang Technological University, School of Chemical and Biomedical Engineering (Singapore); Loo, Say Chye Joachim, E-mail: joachimloo@ntu.edu.sg [Nanyang Technological University, School of Materials Science and Engineering (Singapore); Tan, Timothy Thatt Yang, E-mail: tytan@ntu.edu.sg [Nanyang Technological University, School of Chemical and Biomedical Engineering (Singapore)

    2012-08-15

    This work reports an efficient visible and UV-light-activated boron and nitrogen codoped TiO{sub 2} porous film prepared via a 'green' and direct coating approach. Such photocatalyst is highly promising for solar depollution application due to its efficient photocatalytic activities in both visible and UV spectrum. The preparation method avoids the use of organic solvents, which are usually more expensive and hazardous compared with water. Using stearic acid as the model organic pollutant, the visible-light photocatalytic activity of optimized porous B-N-codoped TiO{sub 2} film (p-3B-N-TiO{sub 2}) is 3 times higher than that of porous N-doped TiO{sub 2} (p-N-TiO{sub 2}) film, while its UV photocatalytic activity is almost double that of p-N-TiO{sub 2} film and comparable to that of porous TiO{sub 2}. The enhancement in photocatalytic activity is attributed to higher surface area due to the porous structure, improved visible-light absorption attributed to interstitially substituted boron atoms, and coexistence of boron and nitrogen dopants which may reduce Ti{sup 3+} recombination centers.

  9. An efficient visible and UV-light-activated B–N-codoped TiO2 photocatalytic film for solar depollution prepared via a green method

    International Nuclear Information System (INIS)

    Xu Qingchi; Zhang Yan; He Ziming; Loo, Say Chye Joachim; Tan, Timothy Thatt Yang

    2012-01-01

    This work reports an efficient visible and UV-light-activated boron and nitrogen codoped TiO 2 porous film prepared via a “green” and direct coating approach. Such photocatalyst is highly promising for solar depollution application due to its efficient photocatalytic activities in both visible and UV spectrum. The preparation method avoids the use of organic solvents, which are usually more expensive and hazardous compared with water. Using stearic acid as the model organic pollutant, the visible-light photocatalytic activity of optimized porous B–N-codoped TiO 2 film (p-3B–N–TiO 2 ) is 3 times higher than that of porous N-doped TiO 2 (p-N–TiO 2 ) film, while its UV photocatalytic activity is almost double that of p-N–TiO 2 film and comparable to that of porous TiO 2 . The enhancement in photocatalytic activity is attributed to higher surface area due to the porous structure, improved visible-light absorption attributed to interstitially substituted boron atoms, and coexistence of boron and nitrogen dopants which may reduce Ti 3+ recombination centers.

  10. Thermoluminescent properties of polycrystalline carbon doped LaAlO{sub 3}/La(OH){sub 3} crystals synthesized by solid state reaction for application in UV dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Alves, N.; Oliveira de F, L. [Federal University of the State of Minas Gerais, Department of Nuclear Engineering, Av. Pres. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil); Barbosa F, W., E-mail: neire.radiologia@yahoo.com.br [Nuclear Technology Development Center, 941, 30161-970 Belo Horizonte, Minas Gerais (Brazil)

    2017-10-15

    It is well known that UV radiation can induce certain deleterious effects, such as erythema, painful inflammation of the membrane of the eye and skin cancer. Therefore, it has been pushing the research for producing new and high performance UV sensitive Tl materials. There is an increasing interest in the development of new Tl materials for ultraviolet (UV) dosimetry purposes, owing to simplicity of the sample readout compared to other techniques. In this paper, thermoluminescence and dosimetric characteristics of pure and carbon doped lanthanum aluminate and hydroxide lanthanum crystals, irradiated with different UV doses, were studied and discussed. All samples studied were produced by solid state reaction method with different mixing methodologies. Characterization of sintered powders by X-ray diffraction, UV-Vis spectrophotometry and Ftir spectroscopy were performed. XRD data confirmed the LaAlO{sub 3} and La(OH){sub 3} crystalline phases. The thermoluminescent study revealed that all compositions presented high UV sensibility. The sample which was grown by first sintering La{sub 2}O{sub 3} together carbon atoms and then sintering again in order to obtain La{sub 2}O{sub 3}:C together Al{sub 2}O{sub 3}, presented the best linear dose response over UV doses ranging from 0.042 to 0.63 mJ/cm{sup 2}, with correlation coefficients equal to 0.99931. The synthesis methodology used was very efficient to obtain crystals with high Tl output intensities for low exposure rate UV R fields. (Author)

  11. Systematic mutagenesis method for enhanced production of bacitracin by Bacillus licheniformis mutant strain UV-MN-HN-6

    Directory of Open Access Journals (Sweden)

    Muhammad Nauman Aftab

    2012-03-01

    Full Text Available The purpose of the current study was intended to obtain the enhanced production of bacitracin by Bacillus licheniformis through random mutagenesis and optimization of various parameters. Several isolates of Bacillus licheniformis were isolated from local habitat and isolate designated as GP-35 produced maximum bacitracin production (14±0.72 IU ml-1. Bacitracin production of Bacillus licheniformis GP-35 was increased to 23±0.69 IU ml-1 after treatment with ultraviolet (UV radiations. Similarly, treatment of vegetative cells of GP-35 with chemicals like N-methyl N'-nitro N-nitroso guanidine (MNNG and Nitrous acid (HNO2 increased the bacitracin production to a level of 31±1.35 IU ml-1 and 27±0.89 IU ml-1 respectively. Treatment of isolate GP-35 with combined effect of UV and chemical treatment yield significantly higher titers of bacitracin with maximum bacitracin production of 41.6±0.92 IU ml-1. Production of bacitracin was further enhanced (59.1±1.35 IU ml-1 by optimization of different parameters like phosphate sources, organic acids as well as temperature and pH. An increase of 4.22 fold in the production of bacitracin after mutagenesis and optimization of various parameters was achieved in comparison to wild type. Mutant strain was highly stable and produced consistent yield of bacitracin even after 15 generations. On the basis of kinetic variables, notably Yp/s (IU/g substrate, Yp/x (IU/g cells, Yx/s (g/g, Yp/s, mutant strain B. licheniformis UV-MN-HN-6 was found to be a hyperproducer of bacitracin.

  12. UV and visible activation of Cr(III)-doped TiO2 catalyst prepared by a microwave-assisted sol-gel method during MCPA degradation.

    Science.gov (United States)

    Mendiola-Alvarez, S Y; Guzmán-Mar, J L; Turnes-Palomino, G; Maya-Alejandro, F; Hernández-Ramírez, A; Hinojosa-Reyes, L

    2017-05-01

    Photocatalytic degradation of 4-chloro-2-methylphenoxyacetic acid (MCPA) in aqueous solution using Cr(III)-doped TiO 2 under UV and visible light was investigated. The semiconductor material was synthesized by a microwave-assisted sol-gel method with Cr(III) doping contents of 0.02, 0.04, and 0.06 wt%. The catalyst was characterized using X-ray powder diffraction (XRD), scanning electron microscopy (SEM), nitrogen physisorption, UV-Vis diffuse reflectance spectroscopy (DRS), and atomic absorption spectroscopy (AAS). The photocatalytic activity for the photodegradation of MCPA was followed by reversed-phase high-performance liquid chromatography (HPLC) and total organic carbon (TOC) analysis. The intermediates formed during degradation were identified using gas chromatography-mass spectrometry (GC-MS). Chloride ion evolution was measured by ion chromatography. Characterization results showed that Cr(III)-doped TiO 2 materials possessed a small crystalline size, high surface area, and mesoporous structure. UV-Vis DRS showed enhanced absorption in the visible region as a function of the Cr(III) concentration. The Cr(III)-doped TiO 2 catalyst with 0.04 wt% of Cr(III) was more active than bare TiO 2 for the degradation of MCPA under both UV and visible light. The intermediates identified during MCPA degradation were 4-chloro-2-methylphenol (CMP), 2-(4-hydroxy-2-methylphenoxy) acetic acid (HMPA), and 2-hydroxybuta-1,3-diene-1,4-diyl-bis (oxy)dimethanol (HBDM); the formation of these intermediates depended on the radiation source.

  13. Technique of radiation polymerization in fine art conservation: a potentially new method of restoration and preservation. [Uv and electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Garnett, J.L. (Univ. of New South Wales, Kensington, Australia); Major, G.

    1982-01-01

    The technique of using radiation polymerization for the restoration and preservation of art treasures is considered. The processes discussed include both radiation grafting and rapid cure procedures, particularly reactions initiated by uv and eb. Representative examples where the technique has already been used are treated including typical applications with paintings, tapestries, leather and archival repair. The structure of the monomers and oligomers used in both grafting and rapid cure systems is outlined. The experimental conditions where grafting may occur during radiation rapid cure processing are discussed. Possible future developments of the technique are outlined. 1 figure, 8 tables.

  14. Determination of Alkaloid Contents in Various Tissues of Coptis Chinensis Franch. by Reversed Phase-High Performance Liquid Chromatography and Ultraviolet Spectrophotometry.

    Science.gov (United States)

    Yang, Yanfang; Peng, Jingling; Li, Fangping; Liu, Xin; Deng, Meng; Wu, Hezhen

    2017-05-01

    A simple and intuitive method for optimizing the chemical constituents of Coptis Chinensis Franch. is important to assess its quality and clinical efficacy. An high performance liquid chromatography and ultraviolet spectrophotometry method was developed for the determination of berberine hydrochloride, palmatine chloride, jatrorrhizine hydrochloride, epiberberine, coptisine, columbamine and magnoflorine in various tissues (i.e., phloem, xylem and medulla) and rizhome of C. Chinensis Franch. The transection of rhizome from outside-in includes cork layer, cortex, phloem, cambium, xylem and medulla. Cork layer consists of dead cells, and therefore is not of any research significance. Cortex, phloem and cambium were almost impossible to separate, therefore they were studied as a whole in our experiments. They were collectively referred to as "phloem". The analytes were separated on a Gemini-NX C18 (250 mm × 4.6 mm, 5 μm) reversed phase column using a gradient elution of acetonitrile-0.03 mol/L ammonium acetate solution (containing 0.1% triethylamine and 0.6% ammonium hydroxide) as the mobile phase at a flow rate of 1.0 mL/min and UV detection at 270 nm. The method allowing the simultaneous quantification of seven major active constituents was optimized and validated for linearity, precision, accuracy, limits of detection (LOD) and quantification. The LOD ranged from 0.102 to 0.651 mg/mL (r ≥ 0.9993). Accuracy, precision and recovery were all within the required limits. The average recovery was between 100.14% and 102.75% and the relative standard deviations were spectrophotometry at 345 nm wavelength. Based on contents of the seven constituents and clustering result, this investigation suggests that there are significant differences in the distribution of seven alkaloids in the tissues examined. Furthermore, the total alkaloid content in xylem is relatively lower than that in phloem, medulla and rhizome. © The Author 2017. Published by Oxford University Press. All

  15. Development and validation of bioanalytical UHPLC-UV method for simultaneous analysis of unchanged fenofibrate and its metabolite fenofibric acid in rat plasma: Application to pharmacokinetics

    Directory of Open Access Journals (Sweden)

    Rayan G. Alamri

    2017-01-01

    Full Text Available A simple, precise, selective and fast ultra-high performance liquid chromatography (UHPLC-UV method has been developed and validated for the simultaneous determination of a lipid regulating agent fenofibrate and its metabolite fenofibric acid in rat plasma. The chromatographic separation was carried out on a reversed-phase Acquity® BEH C18 column using methanol–water (65:35, v/v as the mobile phase. The isocratic flow was 0.3 ml/min with rapid run time of 2.5 min and UV detection was at 284 nm. The method was validated over a concentration range of 100–10000 ng/ml (r2 ⩾ 0.9993. The selectivity, specificity, recovery, accuracy and precision were validated for determination of fenofibrate/fenofibric acid in rat plasma. The lower limits of detection and quantitation of the method were 30 and 90 ng/ml for fenofibrate and 40 and 100 ng/ml for fenofibric acid, respectively. The within and between-day coefficients of variation were less than 5%. The validated method has been successfully applied to measure the plasma concentrations in pharmacokinetics study of fenofibrate in an animal model to illustrate the scope and application of the method.

  16. Traceability of Boletaceae mushrooms using data fusion of UV-visible and FTIR combined with chemometrics methods.

    Science.gov (United States)

    Yao, Sen; Li, Tao; Liu, HongGao; Li, JieQing; Wang, YuanZhong

    2018-04-01

    Boletaceae mushrooms are wild-grown edible mushrooms that have high nutrition, delicious flavor and large economic value distributing in Yunnan Province, China. Traceability is important for the authentication and quality assessment of Boletaceae mushrooms. In this study, UV-visible and Fourier transform infrared (FTIR) spectroscopies were applied for traceability of 247 Boletaceae mushroom samples in combination with chemometrics. Compared with a single spectroscopy technique, data fusion strategy can obviously improve the classification performance in partial least square discriminant analysis (PLS-DA) and grid-search support vector machine (GS-SVM) models, for both species and geographical origin traceability. In addition, PLS-DA and GS-SVM models can provide 100.00% accuracy for species traceability and have reliable evaluation parameters. For geographical origin traceability, the accuracy of prediction in the PLS-DA model by data fusion was just 64.63%, but the GS-SVM model based on data fusion was 100.00%. The results demonstrated that the data fusion strategy of UV-visible and FTIR combined with GS-SVM could provide a higher synergic effect for traceability of Boletaceae mushrooms and have a good generalization ability for the comprehensive quality control and evaluation of similar foods. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  17. PRECISION SPECTROPHOTOMETRY AT THE LEVEL OF 0.1%

    International Nuclear Information System (INIS)

    Yan Renbin

    2011-01-01

    Accurate relative spectrophotometry is critical for many science applications. Small wavelength-scale residuals in the flux calibration can significantly impact the measurements of weak emission and absorption features in the spectra. Using Sloan Digital Sky Survey data, we demonstrate that the average spectra of carefully selected red-sequence galaxies can be used as a spectroscopic standard to improve the relative spectrophotometry precision to 0.1% on small wavelength scales (from a few to hundreds of Angstroms). We achieve this precision by comparing stacked spectra across tiny redshift intervals. The redshift intervals must be small enough that any systematic stellar population evolution is minimized and is less than the spectrophotometric uncertainty. This purely empirical technique does not require any theoretical knowledge of true galaxy spectra. It can be applied to all large spectroscopic galaxy redshift surveys that sample a large number of galaxies in a uniform population.

  18. Two-dimensional spectrophotometry of planetary nebulae by CCD imaging

    International Nuclear Information System (INIS)

    Jacoby, G.H.; Africano, J.L.; Quigley, R.J.; Western Washington Univ., Bellingham, WA)

    1987-01-01

    The spatial distribution of the electron temperature and density and the ionic abundances of O(+), O(2+), N(+), and S(+) have been derived from CCD images of the planetary nebulae NGC 40 and NGC 6826 taken in the important emission lines of forbidden O II, forbidden O III, H-beta, forbidden N II, and forbidden S II. The steps required in the derivation of the absolute fluxes, line, ratios, and ionic abundances are outlined and then discussed in greater detail. The results show that the CCD imaging technique for two-dimensional spectrophotometry can effectively compete with classical spectrophotometry, providing the added benefits of complete spatial coverage at seeing-disk spatial resolution. The multiplexing in the spatial dimension, however, results in a loss of spectral information, since only one emission line is observed at any one time. 37 references

  19. EVALUATING THE ACCUMULATION TREND OF L-DOPA IN DARK-GERMINATED SEEDS AND SUSPENSION CULTURES OF Phaseolus vulgaris L. BY AN EFFICIENT UV-SPECTROPHOTOMETRIC METHOD

    Directory of Open Access Journals (Sweden)

    Samira Rahmani-Nezhad

    Full Text Available Seed germination and plant cell cultures provide an alternative mean for producing secondary metabolites. The present study is an attempt to evaluate the effect of seed dark germination and some elicitors and precursors on the production of L-DOPA in Phaseolus vulgaris L. Callus cultured on Murashige and Skoog medium supplemented with various concentrations of different plant growth regulators. L-DOPA produced was quantified by UV-spectrophotometric method. In this study, a user-friendly, quick, and economical UV-spectrophotometric method was described to determine L-DOPA content in extracts from 33 biotypes of Phaseolus vulgaris L. The method is based on the nitrosation of L-DOPA to form a yellow solution and then formation of a red solution by adding base which is measurable at 470 nm. According to our statistical studies, this method showed high efficiency and selectivity for quantitative determination of L-DOPA in herbal extracts from dried plant seeds, dark-germinated seeds and callus cultures. L-DOPA content in dark-germinated seeds and suspension cultures increased significantly to approximately several-fold compared to the control. The implication from this study is that elicitor treatment and precursor feeding of Phaseolus vulgaris L. can significantly improve the parkinson’s relevant L-DOPA content.

  20. Validation of a high-performance liquid chromatographic method with UV detection for the determination of ethopabate residues in poultry liver.

    Science.gov (United States)

    Granja, Rodrigo H M M; Niño, Alfredo M Montes; Zucchetti, Roberto A M; Niño, Rosario E Montes; Salerno, Alessandro G

    2008-01-01

    Ethopabate is frequently used in the prophylaxis and treatment of coccidiosis in poultry. Residues of this drug in food present a potential risk to consumers. A simple, rapid, and sensitive column high-performance liquid chromatographic (HPLC) method with UV detection for determination of ethopabate in poultry liver is presented. The drug is extracted with acetonitrile. After evaporation, the residue is dissolved with an acetone-hexane mixture and cleaned up by solid-phase extraction using Florisil columns. The analyte is then eluted with methanol. LC analysis is carried out on a C18 5 microm Gemini column, 15 cm x 4.6 mm. Ethopabate is quantified by means of UV detection at 270 nm. Parameters such as decision limit, detection capability, precision, recovery, ruggedness, and measurement uncertainty were calculated according to method validation guidelines provided in 2002/657/EC and ISO/IEC 17025:2005. Decision limit and detection capability were determined to be 2 and 3 microg/kg, respectively. Average recoveries from poultry samples fortified with 10, 15, and 20 microg/kg levels of ethopabate were 100-105%. A complete statistical analysis was performed on the results obtained, including an estimation of the method uncertainty. The method is to be implemented into Brazil's residue monitoring and control program for ethopabate.

  1. Selective determination of thorium in water using dual-wavelength β-correction spectrophotometry and the reagent 4-(2-pyridylazo)-resorcinol

    International Nuclear Information System (INIS)

    Kadi, M.W.; El-Shahawi, M.S.

    2011-01-01

    A simple, fast, low cost, and precise direct β-correction spectrophotometric method was developed for thorium determination in water. The method is based on the reaction of Th(IV) with 4-(2-pyridylazo)-resorcinol (PAR) in aqueous solution of pH 5-6 and measuring the absorbance of the resulting red-colored complex at λ max 497 nm. The effective molar absorptivity of the Th(IV)-PAR complex was 2.52 x 10 4 L mol -1 cm -1 . Beer's law and Ringbom plots were obeyed in the concentration range 0.04-2.0 and 0.07-1.2 μg mL -1 of thorium ions using β-correction spectrophotometry, respectively. The limits of detection and quantification of Th(IV) were 0.02 and 0.066 μg mL -1 , respectively. The developed method was applied for the analysis of thorium in certified reference material (IAEA-soil-7), tap-, underground- and Red-sea water samples. The validation of the method was also tested by comparison with data obtained by ICP-MS. The method is convenient, less sensitive to common interfering species and less laborious than most of published methods. The statistical treatment of data in terms of Student t-tests and variance ratio f-tests has revealed no significance differences. The structure of the Th(IV)-PAR complex was determined with the aid of spectroscopic measurements (UV-Visible and Fourier Transform Infrared Spectroscopy). (author)

  2. A simple and sensitive HPLC method for analysis of imipramine in human plasma with UV detection and liquid-liquid extraction: Application in bioequivalence studies.

    Science.gov (United States)

    Rezazadeh, Mahboubeh; Emami, Jaber

    2016-01-01

    High-performance liquid chromatography (HPLC) methods employing ultraviolet (UV) detector are not sufficiently sensitive to measure the low plasma concentrations following single oral dose of imipramine. Therefore, in the present study a simple, rapid and yet sensitive HPLC method with UV detection was developed and validated for quantitation of imipramine in human plasma samples. An efficient liquid-liquid extraction (LLE) of imipramine from plasma with the mixture of hexane/isoamyl alcohol (98:2) and back extraction of the drug in acidic medium concomitant with evaporation of organic phase allowed the use of UV detector to conveniently measure plasma levels of this compound as low level as 3 ng/ml. Separation was achieved on a μ-Bondapak C18 HPLC column using sodium hydrogen phosphate solution (0.01 M)/acetonitrile (60/40 v/v) at pH 3.5 ± 0.1 at 1.5 ml/min. Trimipramine was used as the internal standard for analysis of plasma samples. The retention times for imipramine and trimipramine were 4.3 and 5.2 min, respectively. Calibration curve was linear in the range of 3-40 ng/ml using human plasma with the average extraction recovery of 85 ± 5%. Imipramine was found to be stable in plasma samples with no evidence of degradation during three freeze-thaw cycles and three months storage at -70°C. The current validated method was finally applied in bioequivalence studies of two different imipramine products according to a standard two-way crossover design with a two weeks washout period.

  3. Validation of an HPLC-UV method for the determination of ceftriaxone sodium residues on stainless steel surface of pharmaceutical manufacturing equipments.

    Science.gov (United States)

    Akl, Magda A; Ahmed, Mona A; Ramadan, Ahmed

    2011-05-15

    In pharmaceutical industry, an important step consists in the removal of possible drug residues from the involved equipments and areas. The cleaning procedures must be validated and methods to determine trace amounts of drugs have, therefore, to be considered with special attention. An HPLC-UV method for the determination of ceftriaxone sodium residues on stainless steel surface was developed and validated in order to control a cleaning procedure. Cotton swabs, moistened with extraction solution (50% water and 50% mobile phase), were used to remove any residues of drugs from stainless steel surfaces, and give recoveries of 91.12, 93.8 and 98.7% for three concentration levels. The precision of the results, reported as the relative standard deviation (RSD), were below 1.5%. The method was validated over a concentration range of 1.15-6.92 μg ml(-1). Low quantities of drug residues were determined by HPLC-UV using a Hypersil ODS 5 μm (250×4.6 mm) at 50 °C with an acetonitrile:water:pH 7:pH 5 (39-55-5.5-0.5) mobile phase at flow rate of 1.5 ml min(-1), an injection volume of 20 μl and were detected at 254 nm. A simple, selective and sensitive HPLC-UV assay for the determination of ceftriaxone sodium residues on stainless steel surfaces was developed, validated and applied. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Non-Powered Spectrophotometry for Lighting

    Data.gov (United States)

    National Aeronautics and Space Administration — This process improvement innovation would like to suggest a non-powered method and tool set that can be developed to assist crewmembers and ground support teams with...

  5. Dynamic range broadening for photomultipliers in kinetic spectrophotometry

    International Nuclear Information System (INIS)

    Rumas, V.K.

    1983-01-01

    The circuit of switching on a photomultiplier with prestage modulation developed for kinetic spectrophotometry purposes is described. Distinguishing features of the scheme are wide range of control pulse duration (40 nc - 2.5 mc) and direct transistor photostart by laser light pulse. In the case of PM prestage modulation for the second dynode modulation depth attains 400 while PM opening time constitutes 40 nc

  6. Spectrophotometry-based detection of carbapenemase producers among Enterobacteriaceae.

    Science.gov (United States)

    Bernabeu, Sandrine; Poirel, Laurent; Nordmann, Patrice

    2012-09-01

    Carbapenem-hydrolyzing ß-lactamases are the most powerful ß-lactamases being able to hydrolyse almost all ß-lactams. They are mostly of the KPC, VIM, IMP, NDM, and OXA-48 type. A spectrophotometry technique based on analysis of the imipenem hydrolysis has been developed that differentiated carbapenemase- from noncarbapenemase producers. This inexpensive technique adapted to screening of carbapenemase producers may be implemented in any reference laboratory worldwide. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. 8-13μm spectrophotometry of galaxies

    International Nuclear Information System (INIS)

    Roche, P.F.; Aitken, D.K.; Whitmore, B.

    1983-01-01

    Spectrophotometry at 8-13 μm of Mkn 231 confirms that the 10 μm minimum is due to large columns of silicate dust in the line-of-sight to the nucleus. Fits to the detailed spectral shape demonstrate that the cool absorbing grains are at the emission (z=0.042) rather than the absorption (z approx.= 0.025) redshift and are located within the nuclear region. (author)

  8. Rapid screening method to study the reactivity of UV filter substances towards skin proteins by high-performance thin-layer chromatography.

    Science.gov (United States)

    Stiefel, C; Schwack, W

    2013-12-01

    Most UV filters used in sunscreens and other cosmetic products contain carbonyl groups, which generally are able to react with peptides or free amino acids of the human skin. To estimate their reactivity, we studied different prominent UV filter substances, octocrylene, ethylhexyl salicylate, 4-t-butyl-4'-methoxydibenzoylmethane, ethylhexyl methoxycinnamate, benzophenone-3, hydroxymethylbenzoyl sulphonic acid, octyldimethyl p-aminobenzoic acid, 3-benzylidene camphor, 4-methylbenzylidene camphor, diethylhexyl butamido triazone and ethylhexyl triazone. A simple screening method using an amino HPTLC plate as protein model was established. The influence of different reaction conditions like heating and irradiation was determined. The ketones BP-3, HMBS and BM-DBM revealed the highest binding rates after both irradiation and heating. After 1 h of irradiation, 82%, 28% and 96%, respectively, were bonded to the amino phase, while heating resulted in values of 52%, 36% and 16%. For BP-3 and HMBS, even storage in the dark at room temperature resulted in a low binding. Contrarily, for the two camphor derivatives 3-BC and 4-MBC, only irradiation led to a slightly turnover. UV filters with ester groups also showed a different behaviour depending on their main skeleton. While OCR especially reacted under heating with the amino phase, resulting in 36% of bound species after one hour, UV irradiation particularly encouraged a reaction of the other esters. After 1 h irradiation, 15% of EHMC, 38% of EHS and 48% of OD-PABA were bonded to the amino groups of the HPTLC plate, whereas the reactivity of the two triazones, EHT and DEBT, was comparatively low. Especially the UV filters BP-3, BM-DBM, HMBS, EHMC or OCR, which are commonly known to cause contact dermatitis, showed a high tendency to form adducts with the amino layer. Thus, the amino plate seems to be a proper tool to screen for skin sensitizers. © 2013 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  9. Measurement of uranium concentration by molecular absorption spectrophotometry by means optical fibers; Medicion continua de concentracion de uranio por espectrofotometria de absorcion molecular mediante fibras opticas

    Energy Technology Data Exchange (ETDEWEB)

    Gauna, Alberto C.; Pascale, Ariel A. [Comision Nacional de Energia Atomica, Buenos Aires (Argentina). Centro Atomico Ezeiza. Agencia Minipost

    1996-07-01

    An on-line method for measuring the concentration of uranium in uranyl nitrate-nitric acid aqueous solutions is described. The method is based on molecular absorption spectrophotometry with transmission of light by means of optical fibers. It is ideally suited for control and processes development applications. (author)

  10. Uranium determination by spectrophotometry, in chloride solutions, using titanium (III) as reducer; Determinacao de uranio por espectrofotometria, em solucoes cloridricas, utilizando titanio (III) como redutor

    Energy Technology Data Exchange (ETDEWEB)

    Bastos, E T.R.; Bastos, M B.R.

    1986-08-01

    A simple method for determining uranium in uranium (VI) solutions with the presence of uranium (IV), iron (II), and titanium (IV) in chloridic solution is described. The method comprises in uranium (VI) reduction with titanium (III), acidity adjustment and uranium (IV) spectrophotometry in hydrochloric acid 2 M. (C.G.C.).

  11. UV-Vis microspectrophotometry as a method of differentiation between cotton fibre evidence coloured with reactive dyes.

    Science.gov (United States)

    Was-Gubala, Jolanta; Starczak, Roza

    2015-05-05

    The main purposes of this study was to assess the usefulness of microspectrophotometry (MSP), both in the ultraviolet (UV) and visible (Vis) range for discriminating single cotton fibres dyed with reactive dyes coming from the same manufacturer, as well as the possibility of evaluation of the concentration of dye in an examine fibre. This study utilised woven cotton fabrics dyed with different concentrations of one-compound reactive dyes with the commercial name Cibacron® (at present Novacron®) as the focus of the MSP analysis. The spectra were recorded in the UV-Vis range between 200 and 800nm, in transmission mode. The results from this study illustrated that all of the analysed cotton samples dyed with reactive dyes were distinguishable between each other with the use of MSP, mostly in the visible, and also in ultraviolet range. The limit for applied MSP techniques was 0.18% of the concentration of a dye in the textile sample. The results indicate that based on the absorbance measurements for fibres constituting e.g. forensic traces it was not possible to estimate the concentration of the dye in the fibre because Beer's law did not obey. The intra-sample, and inter- sample variation, as well as dichroism effect in a case of a cotton fibres dyed with reactive dye were observed. On the basis of the results obtained for each analysed cotton sample, it was concluded that there was no correlation between colour uniformity in cotton fabric (changes in lightness, red/green and yellow/blue colour) and concentration of the reactive dye. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. UV-Vis microspectrophotometry as a method of differentiation between cotton fibre evidence coloured with reactive dyes

    Science.gov (United States)

    Was-Gubala, Jolanta; Starczak, Roza

    2015-05-01

    The main purposes of this study was to assess the usefulness of microspectrophotometry (MSP), both in the ultraviolet (UV) and visible (Vis) range for discriminating single cotton fibres dyed with reactive dyes coming from the same manufacturer, as well as the possibility of evaluation of the concentration of dye in an examine fibre. This study utilised woven cotton fabrics dyed with different concentrations of one-compound reactive dyes with the commercial name Cibacron® (at present Novacron®) as the focus of the MSP analysis. The spectra were recorded in the UV-Vis range between 200 and 800 nm, in transmission mode. The results from this study illustrated that all of the analysed cotton samples dyed with reactive dyes were distinguishable between each other with the use of MSP, mostly in the visible, and also in ultraviolet range. The limit for applied MSP techniques was 0.18% of the concentration of a dye in the textile sample. The results indicate that based on the absorbance measurements for fibres constituting e.g. forensic traces it was not possible to estimate the concentration of the dye in the fibre because Beer's law did not obey. The intra-sample, and inter- sample variation, as well as dichroism effect in a case of a cotton fibres dyed with reactive dye were observed. On the basis of the results obtained for each analysed cotton sample, it was concluded that there was no correlation between colour uniformity in cotton fabric (changes in lightness, red/green and yellow/blue colour) and concentration of the reactive dye.

  13. Miniaturized and green method for determination of chemical oxygen demand using UV-induced oxidation with hydrogen peroxide and single drop microextraction

    International Nuclear Information System (INIS)

    Akhoundzadeh, Jeyran; Chamsaz, Mahmoud; Costas, Marta; Lavilla, Isela; Bendicho, Carlos

    2013-01-01

    We report on a green method for the determination of low levels of chemical oxygen demand. It is based on the combination of (a) UV-induced oxidation with hydrogen peroxide, (b) headspace single-drop microextraction with in-drop precipitation, and (c) micro-turbidimetry. The generation of CO 2 after photolytic oxidation followed by its sequestration onto a microdrop of barium hydroxide gives rise to a precipitate of barium carbonate which is quantified by turbidimetry. UV-light induced oxidation was studied in the absence and presence of H 2 O 2 , ultrasound, and ferrous ion. Determinations of chemical oxygen demand were performed using potassium hydrogen phthalate as a model compound. The optimized method gives a calibration curve that is linear between 3.4 and 20 mg L −1 oxygen. The detection limit was 1.2 mg L −1 of oxygen, and the repeatability (as relative standard deviation) was around 5 %. The method was successfully applied to the determination of chemical oxygen demand in different natural waters and a synthetic wastewater. (author)

  14. Assessment of four methods to estimate surface UV radiation using satellite data, by comparison with ground measurements from four stations in Europe

    Science.gov (United States)

    Arola, Antti; Kalliskota, S.; den Outer, P. N.; Edvardsen, K.; Hansen, G.; Koskela, T.; Martin, T. J.; Matthijsen, J.; Meerkoetter, R.; Peeters, P.; Seckmeyer, G.; Simon, P. C.; Slaper, H.; Taalas, P.; Verdebout, J.

    2002-08-01

    Four different satellite-UV mapping methods are assessed by comparing them against ground-based measurements. The study includes most of the variability found in geographical, meteorological and atmospheric conditions. Three of the methods did not show any significant systematic bias, except during snow cover. The mean difference (bias) in daily doses for the Rijksinstituut voor Volksgezondheid en Milieu (RIVM) and Joint Research Centre (JRC) methods was found to be less than 10% with a RMS difference of the order of 30%. The Deutsches Zentrum für Luft- und Raumfahrt (DLR) method was assessed for a few selected months, and the accuracy was similar to the RIVM and JRC methods. It was additionally used to demonstrate how spatial averaging of high-resolution cloud data improves the estimation of UV daily doses. For the Institut d'Aéronomie Spatiale de Belgique (IASB) method the differences were somewhat higher, because of their original cloud algorithm. The mean difference in daily doses for IASB was about 30% or more, depending on the station, while the RMS difference was about 60%. The cloud algorithm of IASB has been replaced recently, and as a result the accuracy of the IASB method has improved. Evidence is found that further research and development should focus on the improvement of the cloud parameterization. Estimation of daily exposures is likely to be improved if additional time-resolved cloudiness information is available for the satellite-based methods. It is also demonstrated that further development work should be carried out on the treatment of albedo of snow-covered surfaces.

  15. A high-throughput screening strategy for nitrile-hydrolyzing enzymes based on ferric hydroxamate spectrophotometry.

    Science.gov (United States)

    He, Yu-Cai; Ma, Cui-Luan; Xu, Jian-He; Zhou, Li

    2011-02-01

    Nitrile-hydrolyzing enzymes (nitrilase or nitrile hydratase/amidase) have been widely used in the pharmaceutical industry for the production of carboxylic acids and their derivatives, and it is important to build a method for screening for nitrile-hydrolyzing enzymes. In this paper, a simple, rapid, and high-throughput screening method based on the ferric hydroxamate spectrophotometry has been proposed. To validate the accuracy of this screening strategy, the nitrilases from Rhodococcus erythropolis CGMCC 1.2362 and Alcaligenes sp. ECU0401 were used for evaluating the method. As a result, the accuracy for assaying aliphatic and aromatic carboxylic acids was as high as the HPLC-based method. Therefore, the method may be potentially used in the selection of microorganisms or engineered proteins with nitrile-hydrolyzing enzymes.

  16. Investigating the Influence of (Deoxy)fluorination on the Lipophilicity of Non-UV-Active Fluorinated Alkanols and Carbohydrates by a New log P Determination Method.

    Science.gov (United States)

    Linclau, Bruno; Wang, Zhong; Compain, Guillaume; Paumelle, Vincent; Fontenelle, Clement Q; Wells, Neil; Weymouth-Wilson, Alex

    2016-01-11

    Property tuning by fluorination is very effective for a number of purposes, and currently increasingly investigated for aliphatic compounds. An important application is lipophilicity (log P) modulation. However, the determination of log P is cumbersome for non-UV-active compounds. A new variation of the shake-flask log P determination method is presented, enabling the measurement of log P for fluorinated compounds with or without UV activity regardless of whether they are hydrophilic or lipophilic. No calibration curves or measurements of compound masses/aliquot volumes are required. With this method, the influence of fluorination on the lipophilicity of fluorinated aliphatic alcohols was determined, and the log P values of fluorinated carbohydrates were measured. Interesting trends and changes, for example, for the dependence on relative stereochemistry, are reported. © 2015 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

  17. Collection/concentration of trace uranium for spectrophotometric detection using activated carbon and first-derivative spectrophotometry

    International Nuclear Information System (INIS)

    El-Sayed, A.A.; Hamed, M.M.; El-Reefy, S.; Hmmad, H.A.

    2007-01-01

    The need exists for preconcentration of trace and ultratrace amounts of uranium from environmental, geological and biological samples. The adsorption of uranium on various solids is important from the purification, environmental, and radioactivity waste disposal points of view. A method is described for the determination of traces of uranium using first-derivative spectrophotometry after adsorptive preconcentration of uranium on activated carbon. Various parameters that influence the adsorptive preconcentration of uranium on activated carbon, viz., pH, amounts of activated carbon and time of stirring and interference of metals have been studied. First-derivative spectrophotometry in conjunction with adsorptive preconcentration of uranium on activated carbon is used for determining uranium at concentration levels down to 20 ppb (w/v). (orig.)

  18. Evaluation of the H-point standard additions method (HPSAM) and the generalized H-point standard additions method (GHPSAM) for the UV-analysis of two-component mixtures.

    Science.gov (United States)

    Hund, E; Massart, D L; Smeyers-Verbeke, J

    1999-10-01

    The H-point standard additions method (HPSAM) and two versions of the generalized H-point standard additions method (GHPSAM) are evaluated for the UV-analysis of two-component mixtures. Synthetic mixtures of anhydrous caffeine and phenazone as well as of atovaquone and proguanil hydrochloride were used. Furthermore, the method was applied to pharmaceutical formulations that contain these compounds as active drug substances. This paper shows both the difficulties that are related to the methods and the conditions by which acceptable results can be obtained.

  19. [Microwave assisted UV electrodeless discharge lamp photochemical degradation of 4-chlorophenol in aquatic solutions].

    Science.gov (United States)

    Ai, Zhi-hui; Jiang, Jun-qing; Yang, Peng; Zhou, Tao; Lu, Xiao-hua

    2004-07-01

    A microwave assisted UV electrodeless discharge lamp system (MW/UV) was used for photo-degradation of 4CP simulated wastewater. In order to evaluate the degradation efficiency of 4CP, UV spectrophotometry and ion chromatography were used for determination of 4CP and Cl- respectively. The degradation rate in MW/UV system was higher than that in the UV system within 120min, which were 52.40% and 21.56% respectively. The degradation efficiency was improved by increasing pH value of the solution, aerating O2 gas, enhancing light intensity, or adding H2O2 oxidant. The degradation of 4CP under MW/UV accords with the first order kinetics equation.

  20. Protection against UV-induced toxicity and lack of mutagenicity of Antarctic Sanionia uncinata

    International Nuclear Information System (INIS)

    Fernandes, A.S; Mazzei, J.L; Oliveira, C.G; Evangelista, H.; Marques, M.R.C.; Ferraz, E.R.A.; Felzenszwalb, I.

    2017-01-01

    Antarctica moss Sanionia uncinata (Hedw.) Loeske is exposed in situ to damaging levels of ultraviolet (UV) radiation. This moss has the ability to respond to UV radiation exposure producing secondary metabolites such as flavonoids, and has been recommended as a potential source of photoprotective compounds and antioxidants. The aim of the present paper was to investigate the free-radical scavenging activity and mutagenic and photomutagenic properties of methanolic (ME), hydroethanolic (HE) and ethanolic (EE) extracts of S. uncinata. The phenolic contents were evaluated by high-performance liquid chromatography (HPLC) and spectrophotometry. The findings showed that ME and EE presented the highest phenolic contents and inhibited free radical-scavenging activity against 2,2′-diphenyl-1 picrylhydrazyl (DPPH) and the HPLC analysis indicated several classes of phenolic acids and flavonoids. The sun protection factors (SPF) were determined by an in vitro method and the results showed significant values. The SPF values of BZ-3 at 50 μg/mL increased significantly in association with ME, HE and EE. The extracts did not induce mutagenicity in auxotrophic Salmonella typhimurium histidine and photomutagenicity was not detected in the TA102 and TA104 strains after exposure to UV-A at doses of up to 6.5 J/cm 2 for the TA102 strain and up to 0.24 J/cm 2 for the TA104 strain. In addition, with the exception of ME, all the extracts induced photoprotective effects in the presence of the TA104 strain at 0.04 J/cm 2 . The present results suggest that S. uncinata extracts did not induce photomutation and showed promise for photoprotection against the photobiological and ROS-inducing effects of the UV-A radiation.

  1. Determination of mercury, lead and cadmium in water by the CRA-atomic absorption spectrophotometry with solvent extraction

    International Nuclear Information System (INIS)

    Shim, Y.B.; Won, M.S.; Kim, C.J.

    1980-01-01

    The method of CRA-atomic absorption spectrophotometer with solvent extraction for the determination of mercury, lead and cadmium in water was studied. The optimum extracting conditions for CRA-atomic absorption spectrophotometry were the following: the complexes of mercury, lead and cadmium with dithizone were separated from the aqueous solution and concentrated into the 10 ml chloroform solution. Back extraction was performed; the concentrated mercury, lead and cadmium was extracted from the chloroform solution into the 10 ml 6-normal aqueous hydrochloric acid solution. In this case, recovery ratios were the following: mercury was 94.7%, lead 97.7% and cadmium 103.6%. The optimum operating conditions for the determination of mercury, lead and cadmium by the CRA-atomic absorption spectrophotometry also were investigated to test the dry step, ash step and atomization step for each metal. The experimental results of standard addition method were the following: the determination limit of each metal within 6% relative deviation was that lead was 0.04 ppb, and cadmium 0.01 ppb. Especially, mercury has been known impossible to determine by CRA-atomic absorption spectrophotometry until now. But in this study, mercury can be determined with CRA-atomic absorption spectrophotometer. Its determination limit was 4 ppb within 8% relative deviation. (author)

  2. Technical note: comparing von Luschan skin color tiles and modern spectrophotometry for measuring human skin pigmentation.

    Science.gov (United States)

    Swiatoniowski, Anna K; Quillen, Ellen E; Shriver, Mark D; Jablonski, Nina G

    2013-06-01

    Prior to the introduction of reflectance spectrophotometry into anthropological field research during the 1950s, human skin color was most commonly classified by visual skin color matching using the von Luschan tiles, a set of 36 standardized, opaque glass tiles arranged in a chromatic scale. Our goal was to establish a conversion formula between the tile-based color matching method and modern reflectance spectrophotometry to make historical and contemporary data comparable. Skin pigmentation measurements were taken on the forehead, inner upper arms, and backs of the hands using both the tiles and a spectrophotometer on 246 participants showing a broad range of skin pigmentation. From these data, a second-order polynomial conversion formula was derived by jackknife analysis to estimate melanin index (M-index) based on tile values. This conversion formula provides a means for comparing modern data to von Luschan tile measurements recorded in historical reports. This is particularly important for populations now extinct, extirpated, or admixed for which tile-based measures of skin pigmentation are the only data available. Copyright © 2013 Wiley Periodicals, Inc.

  3. Colour print workflow and methods for multilayering of colour and decorative inks using UV inkjet for fine art printing

    Science.gov (United States)

    Parraman, Carinna

    2012-01-01

    In order to increase density of colour and improve ink coverage when printing onto a range of non standard substrates, this paper will present research into multi-layering of colour and the appearance of colour at 'n' levels of ink coverage. Returning to our original investigation of artist's requirements when making inkjet prints, these observations are based on empirical approaches that address the need to present physical data that is more useful and meaningful to the designer. The study has used multi-pass printed colour charts to measure colour and to provide users with an understanding at a soft-preview level to demonstrate the appearance of printed colour on different substrates. Test results relating to the appearance of print on different surfaces, and a series of case studies will be presented using recent research into the capabilities of UV printing technology, which has widened the opportunities for the designer to print onto non-standard materials. It will also present a study into layering of greys and gloss in order to improve the appearance of printed images onto metal.

  4. The polarization modulation and fabrication method of two dimensional silica photonic crystals based on UV nanoimprint lithography and hot imprint.

    Science.gov (United States)

    Guo, Shuai; Niu, Chunhui; Liang, Liang; Chai, Ke; Jia, Yaqing; Zhao, Fangyin; Li, Ya; Zou, Bingsuo; Liu, Ruibin

    2016-10-04

    Based on a silica sol-gel technique, highly-structurally ordered silica photonic structures were fabricated by UV lithography and hot manual nanoimprint efforts, which makes large-scale fabrication of silica photonic crystals easy and results in low-cost. These photonic structures show perfect periodicity, smooth and flat surfaces and consistent aspect ratios, which are checked by scanning electron microscopy (SEM) and atomic force microscopy (AFM). In addition, glass substrates with imprinted photonic nanostructures show good diffraction performance in both transmission and reflection mode. Furthermore, the reflection efficiency can be enhanced by 5 nm Au nanoparticle coating, which does not affect the original imprint structure. Also the refractive index and dielectric constant of the imprinted silica is close to that of the dielectric layer in nanodevices. In addition, the polarization characteristics of the reflected light can be modulated by stripe nanostructures through changing the incident light angle. The experimental findings match with theoretical results, making silica photonic nanostructures functional integration layers in many optical or optoelectronic devices, such as LED and microlasers to enhance the optical performance and modulate polarization properties in an economical and large-scale way.

  5. Modeling UV Radiation Feedback from Massive Stars. I. Implementation of Adaptive Ray-tracing Method and Tests

    Science.gov (United States)

    Kim, Jeong-Gyu; Kim, Woong-Tae; Ostriker, Eve C.; Skinner, M. Aaron

    2017-12-01

    We present an implementation of an adaptive ray-tracing (ART) module in the Athena hydrodynamics code that accurately and efficiently handles the radiative transfer involving multiple point sources on a three-dimensional Cartesian grid. We adopt a recently proposed parallel algorithm that uses nonblocking, asynchronous MPI communications to accelerate transport of rays across the computational domain. We validate our implementation through several standard test problems, including the propagation of radiation in vacuum and the expansions of various types of H II regions. Additionally, scaling tests show that the cost of a full ray trace per source remains comparable to that of the hydrodynamics update on up to ∼ {10}3 processors. To demonstrate application of our ART implementation, we perform a simulation of star cluster formation in a marginally bound, turbulent cloud, finding that its star formation efficiency is 12% when both radiation pressure forces and photoionization by UV radiation are treated. We directly compare the radiation forces computed from the ART scheme with those from the M 1 closure relation. Although the ART and M 1 schemes yield similar results on large scales, the latter is unable to resolve the radiation field accurately near individual point sources.

  6. Determination of boron spectrophotometry in thorium sulfate

    International Nuclear Information System (INIS)

    Federgrun, L.; Abrao, A.

    1976-01-01

    A procedure for the determination of microquantities of boron in nuclear grade thorium sulfate is described. The method is based on the extraction of BF - 4 ion associated to monomethylthionine (MMT) in 1,2 - dichloroethane. The extraction of the colored BF - 4 -MMT complex does not allow the presence of sulfuric and phosphoric acids; other anions interfere seriously. This fact makes the dissolution of the thorium sulfate impracticable, since it is insoluble in both acids. On the other hand, the quantitative separation of thorium is mandatory, to avoid the precipitation of ThF 4 . To overcome this difficulty, the thorium sulfate is dissolved using a strong cationic ion exchanger, Th 4+ being totally retained into the resin. Boron is then analysed in the effluent. The procedure allows the determination of 0.2 to 10.0 microgramas of B, with a maximum error of 10%. Thorium sulfate samples with contents of 0.2 to 2.0μg B/gTh have being analysed [pt

  7. The Comparison Of Silicon Analysis For The Uranium Silicide Fuel Using Spectrophotometrical And Gravimetrical Methods

    International Nuclear Information System (INIS)

    Putro, P. K.; Suripto, A.; Putra, S.; Gunanjar

    1996-01-01

    The analysis of silicon content in the uranium silicide fuel spectro-photometrical and gravimetrical method have been performed. The nitrous oxide-acetylene was used in the atomic absorption spectrophotometry (AAS) on the wave length of 251.6 nm, and the mixture of ammonium hepta molybdate complexes and SnC1 2 as reductor were applied during analysis by UV-VIS spectrophotometry (UV-VIS) on the wave length of 757.5 mm. The reagent of HCLO 4 and HNO 3 were used for determining Si content by gravimetrical methods. The results of this comparison is as follows: the accuracy result is around 96.37 % + 0.24 % for the Si concentration up to 300 ppm (the AAS), is 138.60 % = 0.43 % for the Si concentration range between 0.1-1.5 ppm (UV-VIS), and is 51.13 % + 0.8 % for 1 gram of Si (gravimetry). The results also show that the lowest analytical error is obtained by AAS method

  8. Simultaneous Determination of Cobalt (II and Nickel (II By First Order Derivative Spectrophotometry in Micellar Media

    Directory of Open Access Journals (Sweden)

    Rajni Rohilla

    2012-01-01

    Full Text Available A first-derivative spectrophotometry method for the simultaneous determination of Co (II and Ni (II with Alizarin Red S in presence of Triton X-100 is described. Measurements were made at the zero-crossing wavelengths at 549.0 nm for Co (II and 546.0 nm for Ni (II. The linearity is obtained in the range of 0.291- 4.676 μg/ml of Ni (II and 0.293- 4.124 μg/ml of Co (II in the presence of each other by using first derivative spectrophotometric method. The possible interfering effects of various ions were studied. The validity of the method was examined by using synthetic mixtures of Co (II and Ni (II. The developed derivative procedure, using the zero crossing technique, has been successfully applied for the simultaneous analysis of Co (II and Ni (II in spiked water samples.

  9. Quantitative determination of praesodymium(III)-neodymium(III)-holmium(III)-erbium(III) four-component systems by matrix-fourth derivative spectrophotometry

    International Nuclear Information System (INIS)

    Wu Yang; Jinzhang Gao; Jingwan Kang; Guangbi Bai; Cunxiong Li

    1994-01-01

    A new approach is developed through a combination of matrix representation and higher derivative spectrophotometry and can be used to analyse seven four-component mixtures of lanthanide ions, simultaneously, with a recovery of between 92.0 and 107.1%. The method is rapid, sensitive and accurate and is suitable for a large number of samples. (Author)

  10. Quantitative analysis of trivalent uranium and lanthanides in a molten chloride by absorption spectrophotometry

    International Nuclear Information System (INIS)

    Toshiyuki Fujii; Akihiro Uehara; Hajimu Yamana

    2013-01-01

    As an analytical application for pyrochemical reprocessing using molten salts, quantitative analysis of uranium and lanthanides by UV/Vis/NIR absorption spectrophotometry was performed. Electronic absorption spectra of LiCl-KCl eutectic at 773 K including trivalent uranium and eight rare earth elements (Y, La, Ce, Pr, Nd, Sm, Eu, and Gd as fission product elements) were measured in the wavenumber region of 4,500-33,000 cm -1 . The composition of the solutes was simulated for a reductive extraction condition in a pyroreprocessing process for spent nuclear fuels, that is, about 2 wt% U and 0.1-2 wt% rare earth elements. Since U(III) possesses strong absorption bands due to f-d transitions, an optical quartz cell with short light path length of 1 mm was adopted in the analysis. The quantitative analysis of trivalent U, Nd, Pr, and Sm was possible with their f-f transition intensities in the NIR region. The analytical results agree with the prepared concentrations within 2σ experimental uncertainties. (author)

  11. Characterization of pigment/binder - systems in arts via FTIR and UV/Vis/NIR - spectroscopy with special consideration of nondestructive methods

    International Nuclear Information System (INIS)

    Vetter, W.A.

    2014-01-01

    The main focus of this doctoral thesis is on the non-destructive analysis of art objects by using compound specific reflection-UV/Vis/NIR and reflection-FTIR spectroscopy. Based on commercially available instruments, measuring systems have been designed and built to meet the specific requirements of material analysis in the field of art. These systems have been utilized to analyse different types of art objects (watercolour paintings, easel paintings, contemporary graphic art objects) in order to identify the materials used by the artists. Furthermore, two new procedures are presented which allow to build up adequate reference databases from only minimal sample amounts of original watercolour materials of the 19th century. This is a crucial point as both methods require references for the identification of the materials. The results obtained demonstrate that UV/Vis/NIR and FTIR spectroscopy in reflection mode enable the non-destructive identification of a variety of both, organic and inorganic materials, particularly in combination with element specific XRF (X-ray fluorescence analysis) and thus are valuable tools for the analysis of cultural heritage objects. Furthermore, the results have shown that a comparison of the complementary methods strongly facilitated the evaluation of spectra obtained by the particular analytical techniques and hence reliable results could be obtained in many cases. As expected, several frequently used pigments e.g. carbon based blacks, earth pigments and lake pigments could not be identified unambiguously due to methodical limitations. Therefore, the use of additional complementary methods such as Raman spectroscopy and X-ray diffraction (XRD) would be highly desirable. Except a few examples, the characteristics of the radiation used for the investigations did not allow to draw conclusions about the distribution of materials in multilayer structures. For this reason, it still remains necessary to analyse cross-sections of samples for a

  12. Interrelating meteorite and asteroid spectra at UV-Vis-NIR wavelengths using novel multiple-scattering methods

    Science.gov (United States)

    Martikainen, Julia; Penttilä, Antti; Gritsevich, Maria; Muinonen, Karri

    2017-10-01

    Asteroids have remained mostly the same for the past 4.5 billion years, and provide us information on the origin, evolution and current state of the Solar System. Asteroids and meteorites can be linked by matching their respective reflectance spectra. This is difficult, because spectral features depend strongly on the surface properties, and meteorite surfaces are free of regolith dust present in asteroids. Furthermore, asteroid surfaces experience space weathering which affects their spectral features.We present a novel simulation framework for assessing the spectral properties of meteorites and asteroids and matching their reflectance spectra. The simulations are carried out by utilizing a light-scattering code that takes inhomogeneous waves into account and simulates light scattering by Gaussian-random-sphere particles large compared to the wavelength of the incident light. The code uses incoherent input and computes phase matrices by utilizing incoherent scattering matrices. Reflectance spectra are modeled by combining olivine, pyroxene, and iron, the most common materials that dominate the spectral features of asteroids and meteorites. Space weathering is taken into account by adding nanoiron into the modeled asteroid spectrum. The complex refractive indices needed for the simulations are obtained from existing databases, or derived using an optimization that utilizes our ray-optics code and the measured spectrum of the material.We demonstrate our approach by applying it to the reflectance spectrum of (4) Vesta and the reflectance spectrum of the Johnstown meteorite measured with the University of Helsinki integrating-sphere UV-Vis-NIR spectrometer.Acknowledgments. The research is funded by the ERC Advanced Grant No. 320773 (SAEMPL).

  13. Ultraviolet spectrophotometry from Gemini 11 of stars in Orion

    International Nuclear Information System (INIS)

    Morgan, T.H.; Spear, G.G.; Kondo, Y.; Henize, K.G.

    1975-01-01

    Ultraviolet spectrophotometry in the wavelength region 2600--3600 A is reported for the bright early-type stars β, eta, γ, delta, iota, epsilon, sigma, xi, and kappa Ori. The results are in good agreement with other observations, and with the possible exception of the supergiants, are in good agreement with recent line-blanketed model atmospheres. There is evidence that the supergiants possess a small ultraviolet deficiency shortward of 3000 A relative to main-sequence stars of similar spectral type. The most extreme example of this phenomenon is the star kappa Ori

  14. Identification and spectrophotometry of faint southern radio galaxies

    International Nuclear Information System (INIS)

    Spinrad, H.; Kron, R.G.; Hunstead, R.W.

    1980-01-01

    We have observed a mixed sample of southern radio sources, identified on the Palomar sky survey or on previous direct plates taken with medium-aperture reflectors. At CIO we obtained a few deep 4m photographs and SIT spectrophotometry for redshift and continuum-color measurement. Almost all our sources were faint galaxies; the largest redshift measured was for 3C 275, with z=0.480. The ultraviolet continuum of PKS 0400--643, a ''thermal'' galaxy with z=0.476, closely resembles that of 3C 295 and shows some color evolution in U--B compared to nearby giant ellipticals

  15. Spectrophotometry with optical fibers applied to nuclear product processing

    International Nuclear Information System (INIS)

    Boisde, G.; Perez, J.J.; Velluet, M.T.; Jeunhomme, L.B.

    1988-01-01

    Absorption spectrophotometry is widely used in laboratories for composition analysis and quality control of chemical processes. Using optical fibers for transmitting the light between the instrument and the process line allows to improve the safety and productivity of chemical processes, thanks to real time measurements. Such applications have been developed since 1975 in CEA for the monitoring of nuclear products. This has led to the development of fibers, measurement cells, and optical feedthrough sustaining high radiation doses, of fiber/spectrophotometer couplers, and finally of a photodiode array spectrophotometer optimized for being used together with optical fibers [fr

  16. Chemical and UV Mutagenesis.

    Science.gov (United States)

    Bose, Jeffrey L

    2016-01-01

    The ability to create mutations is an important step towards understanding bacterial physiology and virulence. While targeted approaches are invaluable, the ability to produce genome-wide random mutations can lead to crucial discoveries. Transposon mutagenesis is a useful approach, but many interesting mutations can be missed by these insertions that interrupt coding and noncoding sequences due to the integration of an entire transposon. Chemical mutagenesis and UV-based random mutagenesis are alternate approaches to isolate mutations of interest with the potential of only single nucleotide changes. Once a standard method, difficulty in identifying mutation sites had decreased the popularity of this technique. However, thanks to the recent emergence of economical whole-genome sequencing, this approach to making mutations can once again become a viable option. Therefore, this chapter provides an overview protocol for random mutagenesis using UV light or DNA-damaging chemicals.

  17. Evaluation of Catalytic Effects of Chymotrypsin and Cu2+ for Development of UV-Spectroscopic Method for Gelatin-Source Differentiation.

    Science.gov (United States)

    Hamizah, Anis; Hammed, Ademola Monsur; Asiyanbi-H, Tawakalit Tope; Mirghani, Mohamed Elwathig Saeed; Jaswir, Irwandi; Ahamad Fadzillah, Nurrulhidayah Binti

    2017-01-01

    The consumers interest in gelatin authentication is high due to allergic reactions and adoption of Halal and Kosher eating cultures. This research investigated browning development due to enzymatic hydrolysis and presence of Cu 2+ during Maillard reaction of fish, porcine, and bovine gelatin. The rate of browning index samples showed two phases-rapid and slow-for all the gelatin samples and changes in browning index (Δ B index ) were increased (>100%) in presence of Cu 2+ . Δ B index of enzymatic hydrolysates were different among the gelatin species. Fish gelatin hydrolyzate displayed > 400% increase in browning in the first six hours compared to gelatin hydrolyzates from porcine (200%) and bovine (140%). The variation in Δ B index of chymotrypsin digested gelatin in presence of Cu 2+ could be valuable for the development of an efficient UV-spectroscopic method for gelatin differentiation.

  18. Evaluation of Catalytic Effects of Chymotrypsin and Cu2+ for Development of UV-Spectroscopic Method for Gelatin-Source Differentiation

    Directory of Open Access Journals (Sweden)

    Anis Hamizah

    2017-01-01

    Full Text Available The consumers interest in gelatin authentication is high due to allergic reactions and adoption of Halal and Kosher eating cultures. This research investigated browning development due to enzymatic hydrolysis and presence of Cu2+ during Maillard reaction of fish, porcine, and bovine gelatin. The rate of browning index samples showed two phases—rapid and slow—for all the gelatin samples and changes in browning index (ΔBindex were increased (>100% in presence of Cu2+. ΔBindex of enzymatic hydrolysates were different among the gelatin species. Fish gelatin hydrolyzate displayed > 400% increase in browning in the first six hours compared to gelatin hydrolyzates from porcine (200% and bovine (140%. The variation in ΔBindex of chymotrypsin digested gelatin in presence of Cu2+ could be valuable for the development of an efficient UV-spectroscopic method for gelatin differentiation.

  19. Mitoxantrone Loaded Superparamagnetic Nanoparticles for Drug Targeting: A Versatile and Sensitive Method for Quantification of Drug Enrichment in Rabbit Tissues Using HPLC-UV

    Directory of Open Access Journals (Sweden)

    Rainer Tietze

    2010-01-01

    Full Text Available In medicine, superparamagnetic nanoparticles bound to chemotherapeutics are currently investigated for their feasibility in local tumor therapy. After intraarterial application, these particles can be accumulated in the targeted area by an external magnetic field to increase the drug concentration in the region of interest (Magnetic-Drug-Targeting. We here present an analytical method (HPLC-UV, to detect pure or ferrofluid-bound mitoxantrone in a complex matrix even in trace amounts in order to perform biodistribution studies. Mitoxantrone could be extracted in high yields from different tissues. Recovery of mitoxantrone in liver tissue (5000 ng/g was 76±2%. The limit of quantification of mitoxantrone standard was 10 ng/mL ±12%. Validation criteria such as linearity, precision, and stability were evaluated in ranges achieving the FDA requirements. As shown for pilot samples, biodistribution studies can easily be performed after application of pure or ferrofluid-bound mitoxantrone.

  20. Thermal transformation of bioactive caffeic acid on fumed silica seen by UV-Vis spectroscopy, thermogravimetric analysis, temperature programmed desorption mass spectrometry and quantum chemical methods.

    Science.gov (United States)

    Kulik, Tetiana V; Lipkovska, Natalia O; Barvinchenko, Valentyna M; Palyanytsya, Borys B; Kazakova, Olga A; Dudik, Olesia O; Menyhárd, Alfréd; László, Krisztina

    2016-05-15

    Thermochemical studies of hydroxycinnamic acid derivatives and their surface complexes are important for the pharmaceutical industry, medicine and for the development of technologies of heterogeneous biomass pyrolysis. In this study, structural and thermal transformations of caffeic acid complexes on silica surfaces were studied by UV-Vis spectroscopy, thermogravimetric analysis, temperature programmed desorption mass spectrometry (TPD MS) and quantum chemical methods. Two types of caffeic acid surface complexes are found to form through phenolic or carboxyl groups. The kinetic parameters of the chemical reactions of caffeic acid on silica surface are calculated. The mechanisms of thermal transformations of the caffeic chemisorbed surface complexes are proposed. Thermal decomposition of caffeic acid complex chemisorbed through grafted ester group proceeds via three parallel reactions, producing ketene, vinyl and acetylene derivatives of 1,2-dihydroxybenzene. Immobilization of phenolic acids on the silica surface improves greatly their thermal stability. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. A Critical Comparison of Methods for the Analysis of Indigo in Dyeing Liquors and Effluents

    Directory of Open Access Journals (Sweden)

    Valentina Buscio

    2014-08-01

    Full Text Available Indigo is one of the most important dyes in the textile industry. The control of the indigo concentration in dyeing liquors and effluents is an important tool to ensure the reproducibility of the dyed fabrics and also to establish the efficiency of the wastewater treatment. In this work, three analytical methods were studied and validated with the aim to select a reliable, fast and automated method for the indigo dye determination. The first method is based on the extraction of the dye, with chloroform, in its oxidized form. The organic solution is measured by Ultraviolet (UV-visible spectrophotometry at 604 nm. The second method determines the concentration of indigo in its leuco form in aqueous medium by UV-visible spectrophotometry at 407 nm. Finally, in the last method, the concentration of indigo is determined by redox titration with potassium hexacyanoferrate (K3(Fe(CN6. The results indicated that the three methods that we studied met the established acceptance criteria regarding accuracy and precision. However, the third method was considered the most adequate for application on an industrial scale due to its wider work range, which provides a significant advantage over the others.

  2. Determination of Acyclovir in Human Plasma Samples by HPLC Method with UV Detection: Application to Single-Dose Pharmacokinetic Study

    Directory of Open Access Journals (Sweden)

    Dragica Zendelovska

    2015-03-01

    CONCLUSION: Good precision, accuracy, simplicity, sensitivity and shorter time of analysis of the method makes it particularly useful for processing of multiple samples in a limited period of time for pharmacokinetic study of acyclovir.

  3. Studies on antioxidant properties before and after UV- and γ-IR radiation of Bulgarian lavender essential oil isolated from Lavandula Angostifolia Mill

    International Nuclear Information System (INIS)

    Karamalakova, Yanka; Nikolova, Galina; Gadjeva, Veselina; Zheleva, Antoaneta; Sharma, Jyoti; Stanev, Stanko; Arora, Rajesh

    2013-01-01

    At present there is not enough data about different types of radiation on Bulgarian essential oils isolated from medicinal plants. Here we report for the first time our studies on the effects of UV-radiation (290 nm to 320 nm) and γ-radiation (doses of 5 Gy, 10 Gy, 20 Gy and 30 Gy) on Bulgarian lavender essential oil isolated from Lavandulla angustifolia Mill. A spectrophotometry method was used for evaluation of the changes in the reducing power of the Bulgarian lavender oil before and after radiation. The electron donation potential of non-irradiated oil was found to be lower (0.268 ± 0.0244) than those of both, UV-irradiated (0.336 ± 0.0121) and γ-irradiated, oil samples (0.427 ± 0.0251 at 5 Gy radiation, 0.341 ± 0.0371 at 10 Gy; 0.328± 0.0173 at 20 Gy). By direct electron paramagnetic resonance (EPR) spectroscopy, single almost symmetrical EPR signals with different values of the g-factor were registered in non-irradiated (g = 2.0047 ± 0.0002), UV-irradiated (g = 2.01050 ± 0.00005) and γ-irradiated oil samples (g = 2.0017 ± 0.0002), respectively. EPR spectroscopy was used for assessment of the radical scavenging capacity of the non-irradiated and UV- and γ-irradiated samples of the Bulgarian lavender oil towards the stable free radical 1,1-diphenyl- 2-picrylhydrazyl (DPPH). Excellent DPPH radical scavenging capacities were found for UV- and 30 Gy-irradiated lavender oil samples. Based on these preliminary results, we consider that, after proper UV- or γ-radiation treatment, Bulgarian lavender oil might find application as a good radioprotector and antioxidant in cosmetics and medicine

  4. Development of an Ion-Pairing Reagent and HPLC-UV Method for the Detection and Quantification of Six Water-Soluble Vitamins in Animal Feed

    Directory of Open Access Journals (Sweden)

    Ho Jin Kim

    2016-01-01

    Full Text Available A novel and simple method for detecting six water-soluble vitamins in animal feed using high performance liquid chromatography equipped with a photodiode array detector (HPLC/PDA and ion-pairing reagent was developed. The chromatographic peaks of the six water-soluble vitamins were successfully identified by comparing their retention times and UV spectra with reference standards. The mobile phase was composed of buffers A (5 mM PICB-6 in 0.1% CH3COOH and B (5 mM PICB-6 in 65% methanol. All peaks were detected using a wavelength of 270 nm. Method validation was performed in terms of linearity, sensitivity, selectivity, accuracy, and precision. The limits of detection (LODs for the instrument employed in these experiments ranged from 25 to 197 μg/kg, and the limits of quantification (LOQs ranged from 84 to 658 μg/kg. Average recoveries of the six water-soluble vitamins ranged from 82.3% to 98.9%. Method replication resulted in intraday and interday peak area variation of <5.6%. The developed method was specific and reliable and is therefore suitable for the routine analysis of water-soluble vitamins in animal feed.

  5. Rapid modified QuEChERS method for pesticides detection in honey by high-performance liquid chromatography UV-visible

    Directory of Open Access Journals (Sweden)

    Elisabetta Bonerba

    2014-05-01

    Full Text Available The extensive use of pesticides in agriculture plays an important role in bees die-off and allows the presence of residues in hive products, particularly in honey. An accurate and reliable analytical method, based on QuEChERS extractive technique, has been developed for the quantitative determination by high-performance liquid chromatography UV-visible detector of 5 pesticides (Deltamethrin, Dimethoate, Imidacloprid, Acetamiprid, Chlorfenvinphos in honey. The method, according to Commission Directive 2002/63/EC and Regulation 882/2004/EC, provided excellent results with respect to linearity (correlation coefficient up to 0.993, limits of detection and quantification (0.005 and 0.01 μg/mL for Dimethoate, Deltamethrin and Chlorfenvinphos; 0.02 and 0.05 μg/mL for Acetamiprid and Imidacloprid, recovery values (86.4 to 96.3%, precision and relative expanded uncertainty of a measurement, demonstrating the conformity of the this method with the European directives. The proposed method was applied to 23 samples of Apulian honey. None of the investigated pesticides was detected in these samples.

  6. A new method for the quantification of monosaccharides, uronic acids and oligosaccharides in partially hydrolyzed xylans by HPAEC-UV/VIS.

    Science.gov (United States)

    Lorenz, Dominic; Erasmy, Nicole; Akil, Youssef; Saake, Bodo

    2016-04-20

    A new method for the chemical characterization of xylans is presented, to overcome the difficulties in quantification of 4-O-methyl-α-D-glucuronic acid (meGlcA). In this regard, the hydrolysis behavior of xylans from beech and birch wood was investigated to obtain the optimum conditions for hydrolysis, using sulfuric acid. Due to varying linkage strengths and degradation, no general method for complete hydrolysis can be designed. Therefore, partial hydrolysis was applied, yielding monosaccharides and small meGlcA containing oligosaccharides. For a new method by HPAEC-UV/VIS, these samples were reductively aminated by 2-aminobenzoic acid. By quantification of monosaccharides and oligosaccharides, as well as comparison with borate-HPAEC and (13)C NMR-spectroscopy, we revealed that the concentrations meGlcA are significantly underestimated compared to conventional methods. The detected concentrations are 85.4% (beech) and 76.3% (birch) higher with the new procedure. Furthermore, the quantified concentrations of xylose were 9.3% (beech) and 6.5% (birch) higher by considering the unhydrolyzed oligosaccharides as well. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Utilização de linhagens diplóides uvsH//uvsH de Aspergillus nidulans (Ascomycetes para a avaliação do potencial recombinagênico de agentes químicos e físicos uvsH//uvsH diploid strain favors an efficient method to evaluate the recombinagenic effect of chemical and physical agents in Aspergillus nidulans (Ascomycetes

    Directory of Open Access Journals (Sweden)

    Francielle Baptista

    2001-05-01

    Full Text Available O ascomiceto Aspergillus nidulans apresenta-se como um excelente sistema para o estudo da recombinação somática, por passar grande parte de seu ciclo celular em G2 e por apresentar mutações uvs que promovem aumento das freqüências normais de recombinação mitótica (uvsF e uvsH. O presente trabalho teve como objetivo obter uma nova linhagem diplóide de A. nidulans, com características apropriadas para estudos da recombinagênese, tais como: hetererozigose para marcadores nutricionais e de coloração de conidios e homozigose para a mutação uvsH. A maior sensibilidade do diplóide uvsH//uvsH no monitoramento de eventos de recombinação mitótica foi demonstrada através dos mais altos índices de recombinação mitótica espontânea por ele apresentados, em comparação com o diplóide uvsH+//uvsH +. A nova linhagem apresenta-se como uma ferramenta versátil, podendo ser utilizada em diferentes estudos relacionados à recombinação mitótica em A. nidulansAscomycete Aspergillus nidulans is an excellent system for mitotic crossing-over studies. This is due to the fact that much of its cell cycle is passed in G2 and presents uvs mutations that increase frequencies of normal mitotic recombinations (uvsF and uvsH. The aim of this research was to obtain a new diploid strain of A. nidulans with proper characteristics for recombinagenesis investigations, or rather, heterozygous for nutritional markers and conidia coloration and homozygous for uvsH mutation. Higher sensitivity of diploid uvsH//uvsH in the monitoring of mitotic recombination events was shown by higher indexes of the diploid’s spontaneous mitotic recombination when compared with diploid uvsH+//uvsH +. New strain is a versatile tool that may be used in different studies on mitotic recombination in A. nidulans

  8. Spatially Multiplexed Micro-Spectrophotometry in Bright Field Mode for Thin Film Characterization

    Directory of Open Access Journals (Sweden)

    Valerio Pini

    2016-06-01

    Full Text Available Thickness characterization of thin films is of primary importance in a variety of nanotechnology applications, either in the semiconductor industry, quality control in nanofabrication processes or engineering of nanoelectromechanical systems (NEMS because small thickness variability can strongly compromise the device performance. Here, we present an alternative optical method in bright field mode called Spatially Multiplexed Micro-Spectrophotometry that allows rapid and non-destructive characterization of thin films over areas of mm2 and with 1 μm of lateral resolution. We demonstrate an accuracy of 0.1% in the thickness characterization through measurements performed on four microcantilevers that expand an area of 1.8 mm2 in one minute of analysis time. The measured thickness variation in the range of few tens of nm translates into a mechanical variability that produces an error of up to 2% in the response of the studied devices when they are used to measure surface stress variations.

  9. Alternative set of conditions for molybdenum determination by atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Edgar, R.M.

    1975-01-01

    In comparing a newly developed procedure with that recommended by Perkin--Elmer, et al., (Analytical Methods for Atomic Absorption Spectrophotometry, Perkin--Elmer Corp., Norwalk, Conn. 1973) two areas were found in which the new procedure appeared more suitable for Mo determination. If Cr is present in concentrations greater than 100 ppM, the recommended procedure results in an enhancement effect on Mo absorption. This erroneously high result is eliminated when the new procedure is followed. In the recommended procedure, when the sample has to be dissolved in hydrofluoric acid and Al is added to help eliminate interferences, the acid combines with the Al to form insoluble aluminum fluoride. The part that Al plays in eliminating interferences is lessened, because it is no longer in solution

  10. Application of infrared spectrophotometry to the identification of inorganic substances in dosage forms of Antacida group.

    Science.gov (United States)

    Umbreit, M H; Jedrasiewicz, A

    2000-01-01

    Powdered tablets from the Antacida group: Alusal, Milk of Magnesia, Alumag, Maalox, Magnosil, Alugastrin, Malugastrin, Rennie, and components deciding about their antiacidity like Al(OH)3, Mg(OH)2, Mg2Si3O8, NaAl(OH)2CO3, MgAl(OH)(SO4)2, CaCO3, MgCO3, were subjected to infrared spectrophotometric investigations. It was found that infrared spectra of each pharmaceutical compound are different and show a series of characteristic maxima, by which they can be identified with in the spectral range of 4000 cm-1-200 cm-1. Comparison of infrared spectra of finished products with spectra of their components it was showed that the application of infrared spectrophotometry methods enabled us to prove the presence of particular compounds used in formulations. Tablet mass and odorizing agents do not cause significant changes in spectra of the tablets studied, preparations from the Antacida group.

  11. Optimized Analytical Method to Determine Gallic and Picric Acids in Pyrotechnic Samples by Using HPLC/UV (Reverse Phase)

    International Nuclear Information System (INIS)

    Garcia Alonso, S.; Perez Pastor, R. M.

    2013-01-01

    A study on the optimization and development of a chromatographic method for the determination of gallic and picric acids in pyrotechnic samples is presented. In order to achieve this, both analytical conditions by HPLC with diode detection and extraction step of a selected sample were studied. (Author)

  12. A near-UV-converted LiMgBO3:Dy3+ nanophosphor: Surface and spectral investigations

    International Nuclear Information System (INIS)

    Bedyal, A.K.; Kumar, Vinay; Prakash, Ram; Ntwaeaborwa, O.M.; Swart, H.C.

    2015-01-01

    Graphical abstract: - Highlights: • Combustion method was employed to synthesize LiMgBO 3 :Dy 3+ nanophosphors. • The phosphor can be efficiently excited by near-UV chips. • XPS was done to investigate the chemical constitution and chemical bonding state of elements in the LiMgBO 3 : Dy 3+ nanophosphor. • The calculated CIE coordinates (0.45, 0.46) were found to be in the white spectrum region. - Abstract: A near-ultra violet (UV) converted LiMgBO 3 :Dy 3+ nanophosphors have been synthesized by the combustion method. The structural, spectral and optical properties were examined by powder X-ray diffraction, fluorescent spectrophotometry and UV–vis spectroscopy. The excitation spectra of the phosphors contain sharp peaks at 294, 323, 348 and 385 nm due to the 4f–4f transition of the Dy 3+ ion. The phosphor is efficiently excited by near-UV chips. Upon near-UV excitation the phosphor emits intense blue and yellow with a weak red band centered at 484, 573 and 669 nm respectively, ascribed to the transition of Dy 3+ ion from 4 F 9/2 → 6 H 15/2 , 6 H 13/2 , 6 H 11/2 . The diffuse reflectance spectra of the phosphors were consistent with the excitation spectra and were used to calculate the band gap of the material, approximated to be 5.4 eV. The calculated CIE coordinates (0.45, 0.46) under 348 nm excitation were found to be in the white spectrum region. For surface investigation, X-ray photoelectron spectroscopy was used which confirms the presence of all the elements on the surface of the material

  13. Development of cloud point extraction - UV-visible spectrophotometric method for vanadium (V) determination in hydrogeochemical samples

    International Nuclear Information System (INIS)

    Durani, Smeer; Mathur, Neerja; Chowdary, G.S.

    2007-01-01

    The cloud point extraction behavior (CPE) of vanadium (V) using 5,7 dibromo 8-hydroxyquinoline (DBHQ) and triton X 100 was investigated. Vanadium (V) was extracted with 4 ml of 0.5 mg/ml DBHQ and 6 ml of 8% (V/V) triton X 100 at the pH 3.7. A few hydrogeochemical samples were analysed for vanadium using the above method. (author)

  14. Development of an Ion-Pairing Reagent and HPLC-UV Method for the Detection and Quantification of Six Water-Soluble Vitamins in Animal Feed.

    Science.gov (United States)

    Kim, Ho Jin

    2016-01-01

    A novel and simple method for detecting six water-soluble vitamins in animal feed using high performance liquid chromatography equipped with a photodiode array detector (HPLC/PDA) and ion-pairing reagent was developed. The chromatographic peaks of the six water-soluble vitamins were successfully identified by comparing their retention times and UV spectra with reference standards. The mobile phase was composed of buffers A (5 mM PICB-6 in 0.1% CH3COOH) and B (5 mM PICB-6 in 65% methanol). All peaks were detected using a wavelength of 270 nm. Method validation was performed in terms of linearity, sensitivity, selectivity, accuracy, and precision. The limits of detection (LODs) for the instrument employed in these experiments ranged from 25 to 197 μg/kg, and the limits of quantification (LOQs) ranged from 84 to 658 μg/kg. Average recoveries of the six water-soluble vitamins ranged from 82.3% to 98.9%. Method replication resulted in intraday and interday peak area variation of water-soluble vitamins in animal feed.

  15. APPLICATION OF QuEChERS METHOD FOR THE DETERMINATION OF PHENYLUREA HERBICIDES IN BEETROOT BY HPLC WITH UV-VIS DETECTION

    Directory of Open Access Journals (Sweden)

    Magdalena Surma

    2015-02-01

    Full Text Available Phenylurea herbicides are an important group of herbicides utilized in weed control. They have been on sale since the 1950s and are still in common use throughout the world from pre- and post-emergence control of many annual and perennial broad-leaved weeds. The aim of this work was to evaluate the utility of the QuEChERS method for the determination of phenylurea pesticides (chlortoluron, isoproturon, linuron, metobromuron, metoxuron, monolinuron in beetroot by HPLC with UV/Vis detection. Different types of sorbents (PSA, C18, SAX and NH2 and solvents (hexane, ethyl acetate were applied. The obtained results showed that the best recovery ratios were received for the method with PSA and GCB sorbents and using acetonitrile as an extraction solvent with RSD lower than 15% for most compounds. The linearity of calibration curves was higher than 0.98 for all target analytes. The results show that the QuEChERS method can be successfully applied for the determination of phenylurea herbicides in beetroot.

  16. Development of HPLC and UV spectrophotometric methods for the determination of ascorbic acid using hydroxypropyl-β-cyclodextrin and triethanolamine as photostabilizing agents

    International Nuclear Information System (INIS)

    Garnero, Claudia; Longhi, Marcela

    2010-01-01

    In this study, the effect of complex formation with triethanolamine (TEA) alone and in combination with hydroxypropyl-β-cyclodextrin (HP-β-CD) on the photostability of ascorbic acid was evaluated for exposure to artificial and diffuse daylight. The first-order rate constants for the photodegradation reactions were determined. The data obtained showed that these complexes strongly reduced the photodegradation process with an 11- and 35-fold increase in the photostability of ascorbic acid, depending of the ligand concentration and the irradiation source. The multicomponent complex gave a significantly better stabilization for exposure to light than TEA alone. Due to the fact that the complexation extended the exposure of ascorbic acid to light (without molecular changes), UV spectrophotometric and reversed phase high performance liquid chromatographic (HPLC) methods were developed for the quantitative determination of the vitamin in pure form and in pharmaceutical preparations. These methods were statistically validated, all the validation parameters were found to be within the acceptance range. These results demonstrate that the proposed methods are suitable for the quality control of ascorbic acid, providing simple, rapid, precise, accurate and convenient approaches for routine analysis of bulk drug and pharmaceutical formulations.

  17. Development and validation of an HPLC/UV/MS method for simultaneous determination of 18 preservatives in grapefruit seed extract.

    Science.gov (United States)

    Ganzera, Markus; Aberham, Anita; Stuppner, Hermann

    2006-05-31

    Grapefruit seed extracts are used in cosmetics, food supplements, and pesticides because of their antimicrobial properties, but suspicions about the true nature of the active compounds arose when synthetic disinfectants such as benzethonium or benzalkonium chloride were found in commercial products. The HPLC method presented herein allows the quality assessment (qualitative and quantitative) of these products for the first time. On the basis of a standard mixture of 18 preservatives most relevant for food and grapefruit products, a method was developed allowing the baseline separation of all compounds within 40 min. Optimum results were obtained with a C-8 stationary phase and a solvent system comprising aqueous trifluoroacetic acid, acetonitrile, and 2-propanol. The assay was fully validated and shown to be sensitive (LOD or = 96.1%), repeatable (sigma(rel) < or = 3.5%), precise (intra-day variation < or = 4.5%, interday variation < or = 4.1%), and rugged. Without any modifications the method could be adopted for LC-MS experiments, where the compounds of interest were directly assignable in positive ESI mode. The quantitative results of several products for ecofarming confirmed previous studies, as seven out of nine specimens were adulterated with preservatives in varying composition. The samples either contained benzethonium chloride (2.5-176.9 mg/mL) or benzalkonium chloride (138.2-236.3 mg/mL), together with smaller amounts of 4-hydroxybenzoic acid esters, benzoic acid, and salicylic acid.

  18. Simple and ultra-fast recognition and quantitation of compounded monoclonal antibodies: Application to flow injection analysis combined to UV spectroscopy and matching method.

    Science.gov (United States)

    Jaccoulet, E; Schweitzer-Chaput, A; Toussaint, B; Prognon, P; Caudron, E

    2018-09-01

    Compounding of monoclonal antibody (mAbs) constantly increases in hospital. Quality control (QC) of the compounded mAbs based on quantification and identification is required to prevent potential errors and fast method is needed to manage outpatient chemotherapy administration. A simple and ultra-fast (less than 30 s) method using flow injection analysis associated to least square matching method issued from the analyzer software was performed and evaluated for the routine hospital QC of three compounded mAbs: bevacizumab, infliximab and rituximab. The method was evaluated through qualitative and quantitative parameters. Preliminary analysis of the UV absorption and second derivative spectra of the mAbs allowed us to adapt analytical conditions according to the therapeutic range of the mAbs. In terms of quantitative QC, linearity, accuracy and precision were assessed as specified in ICH guidelines. Very satisfactory recovery was achieved and the RSD (%) of the intermediate precision were less than 1.1%. Qualitative analytical parameters were also evaluated in terms of specificity, sensitivity and global precision through a matrix of confusion. Results showed to be concentration and mAbs dependant and excellent (100%) specificity and sensitivity were reached within specific concentration range. Finally, routine application on "real life" samples (n = 209) from different batch of the three mAbs complied with the specifications of the quality control i.e. excellent identification (100%) and ± 15% of targeting concentration belonging to the calibration range. The successful use of the combination of second derivative spectroscopy and partial least square matching method demonstrated the interest of FIA for the ultra-fast QC of mAbs after compounding using matching method. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Simultaneous determination of atorvastatin calcium and olmesartan medoxomil in a pharmaceutical formulation by reversed phase high-performance liquid chromatography, high-performance thin-layer chromatography, and UV spectrophotometric methods.

    Science.gov (United States)

    Soni, Hiral; Kothari, Charmy; Khatri, Deepak; Mehta, Priti

    2014-01-01

    Validated RP-HPLC, HPTLC, and UV spectrophotometric methods have been developed for the simultaneous determination of atorvastatin calcium (ATV) and olmesartan medoxomil (OLM) in a pharmaceutical formulation. The RP-HPLC separation was achieved on a Kromasil C18 column (250 x 4.6 mm, 5 microm particle size) using 0.01 M potassium dihydrogen o-phosphate (pH 4 adjusted with o-phosphoric acid)-acetonitrile (50 + 50, v/v) as the mobile phase at a flow rate of 1.5 mL/min. Quantification was achieved by UV detection at 276 nm. The HPTLC separation was achieved on precoated silica gel 60F254 plates using chloroform-methanol-acetonitrile (4 + 2+ 4, v/v/v) mobile phase. Quantification was achieved with UV detection at 276 nm. The UV-Vis spectrophotometric method was based on the simultaneous equation method that involves measurement of absorbance at two wavelengths, i.e., 255 nm (lambda max of OLM) and 246.2 nm (lambda max of ATV) in methanol. All three methods were validated as per International Conference on Harmonization guidelines. The proposed methods were simple, precise, accurate, and applicable for the simultaneous determination of ATV and OLM in a marketed formulation. The results obtained by applying the proposed methods were statistically analyzed and were found satisfactory.

  20. Optimization of Extraction Conditions and HPTLC - UV Method for Determination of Quinine in Different Extracts of Cinchona species Bark

    Directory of Open Access Journals (Sweden)

    Dharam C. Jain

    2008-10-01

    Full Text Available A simple, precise and accurate high-performance thin-layer chromatographic method has been established for quantitative determination of quinine. Conditions were also optimized for best possible extraction of quinine via varying concentrations of diethyl amine in different solvents (n-hexane, chloroform, ethyl acetate and methanol for maximum recovery of quinine. Methanol modified with 20 % DEA found to be best for highest possible recovery of target analyte quinine. Chromatographic separation of quinine was performed on silica gel 60 F 254 HPTLC plates with ethyl acetate : diethyl amine in the proportion 88 : 12 (v/v, as mobile phase. The determination was carried out using the densitometric absorbance mode at 236 nm. Quinine response was found to be linear over the range 4–24 μg spot −1. The HPTLC method was evaluated in terms of specificity, precision, reproducibility, LOD – LOQ and robustness. Beside these parameters, number of theoretical plates and flow constant were also included as a part of validation

  1. Spectrophotometry of comets Giacobini-Zinner and Halley

    International Nuclear Information System (INIS)

    Tegler, S.C.; O'dell, C.R.

    1987-01-01

    Optical window spectrophotometry was performed on comets Giacobini-Zinner and Halley over the interval 300-1000 nm. Band and band-sequence fluxes were obtained for the brightest features of OH, CN, NH, and C2, special care having been given to determinations of extinction, instrumental sensitivities, and corrections for Fraunhofer lines. C2 Swan band-sequence flux ratios were determined with unprecedented accuracy and compared with the predictions of the detailed equilibrium models of Krishna Swamy et al. (1977, 1979, 1981, and 1987). It is found that these band sequences do not agree with the predictions, which calls into question the assumptions made in deriving the model, namely resonance fluorescence statistical equilibrium. Suggestions are made as to how to resolve this discrepancy. 16 references

  2. Spectrophotometry of comets Giacobini-Zinner and Halley

    Science.gov (United States)

    Tegler, Stephen C.; O'Dell, C. R.

    1987-01-01

    Optical window spectrophotometry was performed on comets Giacobini-Zinner and Halley over the interval 300-1000 nm. Band and band-sequence fluxes were obtained for the brightest features of OH, CN, NH, and C2, special care having been given to determinations of extinction, instrumental sensitivities, and corrections for Fraunhofer lines. C2 Swan band-sequence flux ratios were determined with unprecedented accuracy and compared with the predictions of the detailed equilibrium models of Krishna Swamy et al. (1977, 1979, 1981, and 1987). It is found that these band sequences do not agree with the predictions, which calls into question the assumptions made in deriving the model, namely resonance fluorescence statistical equilibrium. Suggestions are made as to how to resolve this discrepancy.

  3. Airborne spectrophotometry of Comet Halley from 5 to 9 microns

    Science.gov (United States)

    Campins, H.; Bregman, J. D.; Witteborn, F. C.; Wooden, D. H.; Rank, D. M.; Cohen, M.; Allamandola, Louis J.; Tielens, Alexander G. G. M.

    1986-01-01

    Spectrophotometry from 5 to 9 microns (resolution = 0.02) of comet Halley was obtained from the Kuiper Airborne Observatory on 1985 Dec. 12.1 and 1986 April 8.6 and 10.5 UT. Two spectral features are apparent in all the observations, one from 5.24 to 5.6 microns, and the silicate emission feature which has an onset between 7 and 8 microns. There is no evidence for the 7.5 microns feature observed by the Vega 1 spacecraft; the large difference between the areal coverage viewed from the spacecraft and the airplane may explain the discrepancy. Color temperatures significantly higher than a blackbody indicate that small particles are abundant in the coma. Significant spatial and temporal variations in the spectrum show trends similar to those observed from the ground.

  4. Emission flame spectrophotometry of chromium, cobalt, nickel trace amounts

    International Nuclear Information System (INIS)

    Prudnikov, Y.D.; Shapkina, Y.S.

    1976-01-01

    Chromium, cobalt, and nickel were determined in a flame spectrophotometer with a dual diffraction monochromator, DFS-12, in a high-temperature nitrogen-acetylene flame. The effect of ionization and the elements in the oxidizing flame was small. The lower limit of detection for the three elements is 1x10 -2 to 1 x10 -3 μg/ml, and the high selectivity of the analysis permits determining down to 10 -4 % Cr and Ni and to 10 -3 % Co. These elements may be determined in rocks and minerals from solutions prepared for analysis for alkali and alkali-earth elements. The possibilities of emission flame spectrophotometry are as great as those of atomic-absorption analysis, and it may be used for determining Cr, Co, and Ni in rocks and minerals, especially pure substances, metals, and other materials

  5. Direct imaging and spectrophotometry of Comet P/Tempel 2

    International Nuclear Information System (INIS)

    Boehnhardt, H.; Beisser, K.; Vanysek, V.; Mueller, B.E.A.; Weiss, M.

    1990-01-01

    Both direct imaging and spectrophotometry of Comet P/Tempel 2 during May-November 1988 have led to a nuclear diameter determination of the order of about 10 km. Sekanina's (1987) spin-vector model for this comet is judged capable of qualitatively accounting for both the visual light curve of the comet during this period, which exhibited a steep increase perihelion despite the normal, moderate-decrease perihelion, and an asymmetric extension of the fanlike coma in the solar direction. The late activity onset, the possible constant visual brightness immediately afterward, and the deviation of the fan axis orientation from the predicted value in May 1988, may all furnish additional constraints for P/Tempel 2 nucleus modeling. 24 refs

  6. On-line photolithography modeling using spectrophotometry and Prolith/2

    Science.gov (United States)

    Engstrom, Herbert L.; Beacham, Jeanne E.

    1994-05-01

    Spectrophotometry has been applied to optimizing photolithography processes in semiconductor manufacturing. For many years thin film measurement systems have been used in manufacturing for controlling film deposition processes. The combination of film thickness mapping with photolithography modeling has expanded the applications of this technology. Experimental measurements of dose-to-clear, the minimum light exposure dose required to fully develop a photoresist, are described. It is shown how dose-to-clear and photoresist contrast may be determined rapidly and conveniently from measurements of a dose exposure matrix on a monitor wafer. Such experimental measurements may underestimate the dose-to- clear because of thickness variations of the photoresist and underlying layers on the product wafer. Online modeling of the photolithographic process together with film thickness maps of the entire wafer can overcome this problem. Such modeling also provides maps of dose-to- clear and resist linewidth that can be used to estimate and optimize yield.

  7. Discovery and spectrophotometry of high-redshift quasars

    International Nuclear Information System (INIS)

    MacAlpine, G.M.; Feldman, F.R.

    1982-01-01

    We report on the discovery and spectrophotometry of 30 new high-redshift quasars, which were detected using the Curtis Schmidt technique. We also discuss new follow-up spectrophotometry for 23 quasar candidates from University of Michigan Lists I--IV. Our program sample contains eight quasars with z>3, at least five objects exhibiting broad absorption troughs, and a pair of quasars which are 1' apart on the sky and nearly identical in redshift, at z near 2.13. The redshift distribution for the majority of quasars in UM List IV suggests that most of the single-line quasar candidates in the UM List have low to moderate redshifts, with the reported line often being Mg II lambda2798 or C III] lambda1909. For 17 high-redshift quasars where lambda912 at the emission-line redshift could be examined, we did not find any definite Lyman limit cutoffs. Although three objects show a decline of the continuum within 100 A of lambda912, we do not believe them to be unambiguous examples for emission-line clouds situated in the line of sight. When our O I lambda1304 measurements are combined with the data of others to yield a composite spectrum, we obtain O I lambda1304/lambda8446 = 1.35. This suggests reddening with E/sub B/-Vroughly-equal0.23. Finally, our data exhibit a correlation between Lyα emission line velocity widths and redshift. The higher z quasars in the sample tend to have narrower lines, due, at least in part, to bias in the detection technique

  8. Use of reflectance spectrophotometry and colorimetry in a general linear model for the determination of the age of bruises.

    Science.gov (United States)

    Hughes, Vanessa K; Langlois, Neil E I

    2010-12-01

    Bruises can have medicolegal significance such that the age of a bruise may be an important issue. This study sought to determine if colorimetry or reflectance spectrophotometry could be employed to objectively estimate the age of bruises. Based on a previously described method, reflectance spectrophotometric scans were obtained from bruises using a Cary 100 Bio spectrophotometer fitted with a fibre-optic reflectance probe. Measurements were taken from the bruise and a control area. Software was used to calculate the first derivative at 490 and 480 nm; the proportion of oxygenated hemoglobin was calculated using an isobestic point method and a software application converted the scan data into colorimetry data. In addition, data on factors that might be associated with the determination of the age of a bruise: subject age, subject sex, degree of trauma, bruise size, skin color, body build, and depth of bruise were recorded. From 147 subjects, 233 reflectance spectrophotometry scans were obtained for analysis. The age of the bruises ranged from 0.5 to 231.5 h. A General Linear Model analysis method was used. This revealed that colorimetric measurement of the yellowness of a bruise accounted for 13% of the bruise age. By incorporation of the other recorded data (as above), yellowness could predict up to 32% of the age of a bruise-implying that 68% of the variation was dependent on other factors. However, critical appraisal of the model revealed that the colorimetry method of determining the age of a bruise was affected by skin tone and required a measure of the proportion of oxygenated hemoglobin, which is obtained by spectrophotometric methods. Using spectrophotometry, the first derivative at 490 nm alone accounted for 18% of the bruise age estimate. When additional factors (subject sex, bruise depth and oxygenation of hemoglobin) were included in the General Linear Model this increased to 31%-implying that 69% of the variation was dependent on other factors. This

  9. Theoretically Guided Analytical Method Development and Validation for the Estimation of Rifampicin in a Mixture of Isoniazid and Pyrazinamide by UV Spectrophotometer.

    Science.gov (United States)

    Khan, Mohammad F; Rita, Shamima A; Kayser, Md Shahidulla; Islam, Md Shariful; Asad, Sharmeen; Bin Rashid, Ridwan; Bari, Md Abdul; Rahman, Muhammed M; Al Aman, D A Anwar; Setu, Nurul I; Banoo, Rebecca; Rashid, Mohammad A

    2017-01-01

    A simple, rapid, economic, accurate, and precise method for the estimation of rifampicin in a mixture of isoniazid and pyrazinamide by UV spectrophotometeric technique (guided by the theoretical investigation of physicochemical properties) was developed and validated. Theoretical investigations revealed that isoniazid and pyrazinamide both were freely soluble in water and slightly soluble in ethyl acetate whereas rifampicin was practically insoluble in water but freely soluble in ethyl acetate. This indicates that ethyl acetate is an effective solvent for the extraction of rifampicin from a water mixture of isoniazid and pyrazinamide. Computational study indicated that pH range of 6.0-8.0 would favor the extraction of rifampicin. Rifampicin is separated from isoniazid and pyrazinamide at pH 7.4 ± 0.1 by extracting with ethyl acetate. The ethyl acetate was then analyzed at λ max of 344.0 nm. The developed method was validated for linearity, accuracy and precision according to ICH guidelines. The proposed method exhibited good linearity over the concentration range of 2.5-35.0 μg/mL. The intraday and inter-day precision in terms of % RSD ranged from 1.09 to 1.70% and 1.63 to 2.99%, respectively. The accuracy (in terms of recovery) of the method varied from of 96.7 ± 0.9 to 101.1 ± 0.4%. The LOD and LOQ were found to be 0.83 and 2.52 μg/mL, respectively. In addition, the developed method was successfully applied to determine rifampicin combination (isoniazid and pyrazinamide) brands available in Bangladesh.

  10. Determination of chlorpropham (CIPC) residues, in the concrete flooring of potato stores, using quantitative (HPLC UV/VIS) and qualitative (GCMS) methods.

    Science.gov (United States)

    Douglas, Leisa; MacKinnon, Gillian; Cook, Gordon; Duncan, Harry; Briddon, Adrian; Seamark, Steven

    2018-03-01

    Isopropyl-N-(3-chlorophenyl) carbamate (CIPC, common name Chlorpropham) is commonly used for post-harvest sprout inhibition in stored potatoes. It is applied as a thermal fog which results in loss to the fabric of the store and the atmosphere. Recently, there have been concerns in the United Kingdom because of cross contamination of other crop commodities that were stored in buildings with a history of CIPC usage. This cross contamination may have occurred because of retained residues in the fabric of the stores. The retention of CIPC in concrete is poorly understood; therefore the requirement for a robust analytical method for the detection and quantification of CIPC in concrete is a critical first step in tackling this problem. A method using High-Performance Liquid Chromatography with ultraviolet detection (HPLC UV/VIS) was validated. CIPC recoveries at three concentration levels (0.4, 4.0 and 40.0 μg g -1 ) were in the range of 90.7-97.0% with relative standard deviations between 2.14 and 3.01%. The limits of detection and quantification were 0.03 and 0.1 μg g -1 , respectively. This study confirmed that CIPC was persistent in concrete to a depth of 4 cm, with >90% within the top 1 cm of the flooring. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. A screening method based on UV-Visible spectroscopy and multivariate analysis to assess addition of filler juices and water to pomegranate juices.

    Science.gov (United States)

    Boggia, Raffaella; Casolino, Maria Chiara; Hysenaj, Vilma; Oliveri, Paolo; Zunin, Paola

    2013-10-15

    Consumer demand for pomegranate juice has considerably grown, during the last years, for its potential health benefits. Since it is an expensive functional food, cheaper fruit juices addition (i.e., grape and apple juices) or its simple dilution, or polyphenols subtraction are deceptively used. At present, time-consuming analyses are used to control the quality of this product. Furthermore these analyses are expensive and require well-trained analysts. Thus, the purpose of this study was to propose a high-speed and easy-to-use shortcut. Based on UV-VIS spectroscopy and chemometrics, a screening method is proposed to quickly screening some common fillers of pomegranate juice that could decrease the antiradical scavenging capacity of pure products. The analytical method was applied to laboratory prepared juices, to commercial juices and to representative experimental mixtures at different levels of water and filler juices. The outcomes were evaluated by means of multivariate exploratory analysis. The results indicate that the proposed strategy can be a useful screening tool to assess addition of filler juices and water to pomegranate juices. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. Development and validation of a new HPLC-UV method for the simultaneous determination of triclabendazole and ivermectin B1a in a pharmaceutical formulation.

    Science.gov (United States)

    Shurbaji, Maher; Abu Al Rub, Mohamad H; Saket, Munib M; Qaisi, Ali M; Salim, Maher L; Abu-Nameh, Eyad S M

    2010-01-01

    A rapid, simple, and sensitive RP-HPLC analytical method was developed for the simultaneous determination of triclabendazole and ivermectin in combination using a C18 RP column. The mobile phase was acetonitrile-methanol-water-acetic acid (56 + 36 + 7.5 + 0.5, v/v/v/v) at a pH of 4.35 and flow rate of 1.0 mL/min. A 245 nm UV detection wavelength was used. Complete validation, including linearity, accuracy, recovery, LOD, LOQ, precision, robustness, stability, and peak purity, was performed. The calibration curve was linear over the range 50.09-150.26 microg/mL for triclabendazole with r = 0.9999 and 27.01-81.02 microg/mL for ivermectin with r = 0.9999. Calculated LOD and LOQ for triclabendazole were 0.03 and 0.08 microg/mL, respectively, and for ivermectin 0.07 and 0.20 microg/mL, respectively. The intraday precision obtained was 98.71% with RSD of 0.87% for triclabendazole and 100.79% with RSD 0.73% for ivermectin. The interday precision obtained was 99.51% with RSD of 0.35% for triclabendazole and 100.55% with RSD of 0.59% for ivermectin. Robustness was also studied, and there was no significant variation of the system suitability of the analytical method with small changes in experimental parameters.

  13. Isolation and characterization of a degradation product in leflunomide and a validated selective stability-indicating HPLC–UV method for their quantification

    Directory of Open Access Journals (Sweden)

    Balraj Saini

    2015-06-01

    Full Text Available Leflunomide (LLM is subjected to forced degradation under conditions of hydrolysis, oxidation, dry heat, and photolysis as recommended by International Conference on Harmonization guideline Q1A(R2. In total, four degradation products (I–IV were formed under different conditions. Products I, II and IV were formed in alkaline hydrolytic, acidic hydrolytic and alkaline photolytic conditions. LLM and all degradation products were optimally resolved by gradient elution over a C18 column. The major degradation product (IV formed in hydrolytic alkaline conditions was isolated through column chromatography. Based on its 1H NMR, IR and mass spectral data, it was characterized as a British Pharmacopoeial impurity B. The HPLC method was found to be linear, accurate, precise, sensitive, specific, rugged and robust for quantification of LLM as well as product IV. Finally, the method was applied to stability testing of the commercially available LLM tablets. Keywords: Leflunomide, Characterization, Forced degradation, Degradation product, HPLC–UV

  14. Methods and results for calibration and track separation of a GEM based TPC using an UV-laser

    International Nuclear Information System (INIS)

    Ball, Markus

    2008-12-01

    In the last 30 years high energy physics could write an impressive story of success. Since the introduction of the Standard Model (SM), it has met every experimental test. However the final confirmation has to prove the mechanism of electroweak symmetry breaking, which could not be confirmed yet. The most favored theory, which includes the introduction of a Higgs field, could not be verified experimentally. Furthermore there is clear evidence, that the SM is only a low energy description of nature and its principles, as the SM describes only 4 % of the known matter in the universe. There are two different approaches in accelerator driven high energy physics to clarify the open questions. The Large Hadron Collider (LHC) have a good opportunity to measure some of the missing pieces with its high center of mass energy. The International Linear Collider (ILC) will then measure their parameters with high precision. To guarantee this high precision the detectors have to be able to identify every single particle and determine its properties with high accuracy. These high requirements to the single detectors as well as the interconnectivity between all detectors are summarised by the concept of particle flow (PFLOW). This means that all particles must be separable, which includes in particular the main tracking device. A possible candidate for the central tracking device is a Time Projection Chamber (TPC). In this work a TPC with Gas Electron Multipliers (GEM) as gas amplification system was used. The GEMs replace the conventional wire amplification system of the TPC. In this PhD work a method to determine the drift velocity of a TPC was developed and tested using an ultraviolet laser. To ensure a high accuracy of the method all relevant gas parameters were measured with a slow control system. Furthermore the laser was used to investigate the separation capability of nearby tracks. Therefore an existing TPC prototype, which was developed to operate in a 5 T magnet facility

  15. Facile LC-UV methods for simultaneous monitoring of ciprofloxacin and rosuvastatin in API, formulations and human serum.

    Science.gov (United States)

    Arayne, M Saeed; Sultana, Najma; Tabassum, Arman

    2015-02-01

    An efficient, selective and cost-effective liquid chromatographic assay was developed and validated for the simultaneous quantification of ciprofloxacin and rosuvastatin in Active Pharmaceutical Ingredients (API), pharmaceutical formulations and in human serum. The chromatographic system consisted of mobile phase methanol-water, 90:10 v/v at pH 3.0 adjusted with o-phosphoric acid, pumped at 1.0 mL/min through a prepacked Purospher Star C18 (5 µm, 25 × 0.46 cm) column and effluent was monitored at the isosbestic point (255 nm) as well as at the λmax of individual drugs (243 and 271 nm). The method was validated over a linear concentration range of 0.25-15 µg/mL for ciprofloxacin and 0.33-20 µg/mL for rosuvastatin (r(2)  ≥ 0.999). The ranges of reliable response (limits of detection and quantitation) for ciprofloxacin were 3-15 and 9-45 ng/mL and 17-29 and 52-88 ng/mL, respectively, for rosuvastatin in all API, pharmaceutical formulations and human serum. Analytical recovery from human serum was >98% and relative standard deviation (RSD) was <2. The accuracies were 97.13-102.55 and 97.41-101.31% and precisions in RSD were 0.04-1.90 and 0.02-1.23% for ciprofloxacin and rosuvastatin, respectively. No matrix interferences, ion suppression/enhancement and carry-over were detected. The total assay run time was less than 5 min. In another study, for optimum performance the detector was programmed for multiwavelength scanning at the absorption maxima of each component. Consequently, the linearity range was improved and limit of detection and quantitation values were down to 1-4 and 4-12 ng/mL for ciprofloxacin and 3-5 and 9-15 ng/mL for rosuvastatin, respectively. The validation parameters fitted ICH guidelines through the isosbestic and individual λmax approach. The small sample volume and simplicity of preparation make this method suitable for use in human serum samples, pharmaceutical formulations, quality control, drug

  16. Methods and results for calibration and track separation of a GEM based TPC using an UV-laser

    Energy Technology Data Exchange (ETDEWEB)

    Ball, Markus

    2008-12-15

    In the last 30 years high energy physics could write an impressive story of success. Since the introduction of the Standard Model (SM), it has met every experimental test. However the final confirmation has to prove the mechanism of electroweak symmetry breaking, which could not be confirmed yet. The most favored theory, which includes the introduction of a Higgs field, could not be verified experimentally. Furthermore there is clear evidence, that the SM is only a low energy description of nature and its principles, as the SM describes only 4 % of the known matter in the universe. There are two different approaches in accelerator driven high energy physics to clarify the open questions. The Large Hadron Collider (LHC) have a good opportunity to measure some of the missing pieces with its high center of mass energy. The International Linear Collider (ILC) will then measure their parameters with high precision. To guarantee this high precision the detectors have to be able to identify every single particle and determine its properties with high accuracy. These high requirements to the single detectors as well as the interconnectivity between all detectors are summarised by the concept of particle flow (PFLOW). This means that all particles must be separable, which includes in particular the main tracking device. A possible candidate for the central tracking device is a Time Projection Chamber (TPC). In this work a TPC with Gas Electron Multipliers (GEM) as gas amplification system was used. The GEMs replace the conventional wire amplification system of the TPC. In this PhD work a method to determine the drift velocity of a TPC was developed and tested using an ultraviolet laser. To ensure a high accuracy of the method all relevant gas parameters were measured with a slow control system. Furthermore the laser was used to investigate the separation capability of nearby tracks. Therefore an existing TPC prototype, which was developed to operate in a 5 T magnet facility

  17. Rapid measurement of indocyanine green retention by pulse spectrophotometry: a validation study in 70 patients with Child-Pugh A cirrhosis before hepatectomy for hepatocellular carcinoma.

    Science.gov (United States)

    Cheung, Tan To; Chan, See Ching; Chok, Kenneth S H; Chan, Albert C Y; Yu, Wan Ching; Poon, Ronnie T P; Lo, Chung Mau; Fan, Sheung Tat

    2012-06-01

    The indocyanine green (ICG) retention test is the most popular liver function test for selecting patients for major hepatectomy. Traditionally, it is done using spectrophotometry with serial blood sampling. The newly-developed pulse spectrophotometry is a faster alternative, but its accuracy on Child-Pugh A cirrhotic patients undergoing hepatectomy for hepatocellular carcinoma has not been well documented. This study aimed to assess the accuracy of the LiMON(®), one of the pulse spectrophotometry systems, in measuring preoperative ICG retention in these patients and to devise an easy formula for conversion of the results so that they can be compared with classical literature records where ICG retention was measured by the traditional method. We measured the liver function of 70 Child-Pugh A cirrhotic patients before hepatectomy for hepatocellular carcinoma from September 2008 to January 2009. ICG retention at 15 minutes measured by traditional spectrophotometry (ICGR15) was compared with ICG retention at 15 minutes measured by the LiMON (ICGR15(L)). The median ICGR15 was 14.7% (5.6%-32%) and the median ICGR15(L) was 10.4% (1.2%-28%). The mean difference between them was -4.3606. There was a strong correlation between ICGR15 and ICGR15(L) (correlation coefficient, 0.844; 95% confidence interval, 0.762-0.899). The following formula was devised: ICGR15=1.16XICGR15(L)+2.73. The LiMON provides a fast and repeatable way to measure ICG retention at 15 minutes, but with constant underestimation of the real value. Therefore, when comparing results obtained by traditional spectrophotometry and the LiMON, adjustment of results from the latter is necessary, and this can be done with a simple mathematical calculation using the above formula.

  18. METHODS ELABORATION ON DETECTION OF SOME ATYPICAL NEUROLYTIC AGENTS FOR CHEMICAL AND TOXICOLOGICAL ANALYSIS

    Directory of Open Access Journals (Sweden)

    I. P. Remezova

    2014-01-01

    Full Text Available It is necessary to elaborate methods of atypical neuroleptic agents detection as individual substances and in different combinations as well for diagnosis of poisoning by some of them: clozapine, risperidone, sertindole, olanzapine, aripiprazole. The purpose of this work is methods elaboration of detection of clozapine, risperidone, sertindole, olanzapine, aripiprazole, haloperidol, oxazepam, carbamazapine using TLC, HPLC and UV spectrophotometry methods. During this work we used tablet forms of clozapine, risperidone, sertindole, olanzapine, aripiprazole. It is possible to use solution systems like ethanol-water-25% ammonia solution (8:1:1, toluolacetone-ethanol-25% ammonia solution (45:45:7.5:2.5, dioxan-chloroform-acetone-25% ammonia solution (47.5:45:5:2.5 for preliminary examination of atypical neuroleptic agents under study in combination with typical neuroleptics and tranquilizers with undirected analysis (general screening. System of solvents ethyl-acetate-chloroform-25% ammonia solution (85:10:5 is recommended to use for individual screening of risperidone, sertindole, olanzapine, haloperidol, benzol-ethanol-25% ammonia solution (50:10:0.5 system to use for clozapine, sertindole, olanzapine. Ethanol-25% ammonia solution (100:1.5 system is reasonable to use for chromatographic clearance of extracts from biological substances under study. We recommend using HPLC method and UV spectrophotometry for carrying out of a principal examination of clozapine, risperidone, sertindole, olanzapine and aripiprazole in case one of the substances under study is determined in the object.

  19. Development of an HPLC-UV Method for the Analysis of Drugs Used for Combined Hypertension Therapy in Pharmaceutical Preparations and Human Plasma

    Directory of Open Access Journals (Sweden)

    Serife Evrim Kepekci Tekkeli

    2013-01-01

    Full Text Available A simple, rapid, and selective HPLC-UV method was developed for the determination of antihypertensive drug substances: amlodipine besilat (AML, olmesartan medoxomil (OLM, valsartan (VAL, and hydrochlorothiazide (HCT in pharmaceuticals and plasma. These substances are mostly used as combinations. The combinations are found in various forms, especially in current pharmaceuticals as threesome components: OLM, AML, and HCT (combination I and AML, VAL, and HCT (combination II. The separation was achieved by using an RP-CN column, and acetonitrile-methanol-10 mmol orthophosphoric acid pH 2.5 (7 : 13 : 80, v/v/v was used as a mobile phase; the detector wavelength was set at 235 nm. The linear ranges were found as 0.1–18.5 μg/mL, 0.4–25.6 μg/mL, 0.3–15.5 μg/mL, and 0.3–22 μg/mL for AML, OLM, VAL, and HCT, respectively. In order to check the selectivity of the method for pharmaceutical preparations, forced degradation studies were carried out. According to the validation studies, the developed method was found to be reproducible and accurate as shown by RSD ≤6.1%, 5.7%, 6.9%, and 4.6% and relative mean error (RME ≤10.6%, 5.8%, 6.5%, and 6.8% for AML, OLM, VAL, and HCT, respectively. Consequently, the method was applied to the analysis of tablets and plasma of the patients using drugs including those substances.

  20. Determination of silver in soils, sediments, and rocks by organic-chelate extraction and atomic absorption spectrophotometry

    Science.gov (United States)

    Chao, T.T.; Ball, J.W.; Nakagawa, H.M.

    1971-01-01

    A useful method for the determination of silver in soil, sediment, and rock samples in geochemical exploration has been developed. The sample is digested with concentrated nitric acid, and the silver extracted with triisooctyl thiophosphate (TOTP) in methyl isobutyl ketone (MIBK) after dilution of the acid digest to approximately 6 M. The extraction of silver into the organic extractant is quantitative and not affected by the nitric acid concentration from 4 M to 8 M, or by different volumes of TOTP-MIBK. The extracted silver is stable and remains in the organic phase up to several days. The silver concentration is determined by atomic absorption spectrophotometry. ?? 1971.

  1. Derivative spectrophotometry for the determination of faropenem in the presence of degradation products: an application for kinetic studies.

    Science.gov (United States)

    Cielecka-Piontek, Judyta

    2013-07-01

    A simple and selective derivative spectrophotometric method was developed for the quantitative determination of faropenem in pure form and in pharmaceutical dosage. The method is based on the zero-crossing effect of first-derivative spectrophotometry (λ = 324 nm), which eliminates the overlapping effect caused by the excipients present in the pharmaceutical preparation, as well as degradation products, formed during hydrolysis, oxidation, photolysis, and thermolysis. The method was linear in the concentration range 2.5-300 μg/mL (r = 0.9989) at λ = 341 nm; the limits of detection and quantitation were 0.16 and 0.46 μg/mL, respectively. The method had good precision (relative standard deviation from 0.68 to 2.13%). Recovery of faropenem ranged from 97.9 to 101.3%. The first-order rate constants of the degradation of faropenem in pure form and in pharmaceutical dosage were determined by using first-derivative spectrophotometry. A statistical comparison of the validation results and the observed rate constants for faropenem degradation with these obtained with the high-performance liquid chromatography method demonstrated that both were compatible.

  2. Índice UV

    Science.gov (United States)

    Información general sobre el Índice UV que proporciona un pronóstico del riesgo esperado de sobreexposición a la radiación ultravioleta (UV) del sol. El índice UV va acompañado de recomendaciones para protegerse del sol.

  3. uv dye lasers

    International Nuclear Information System (INIS)

    Abakumov, G.A.; Fadeev, V.V.; Khokhlov, R.V.; Simonov, A.P.

    1975-01-01

    The most important property of visible dye lasers, that is, continuous wavelength tuning, stimulated the search for dyes capable to lase in uv. They were found in 1968. Now the need for tunable uv lasers for applications in spectroscopy, photochemistry, isotope separation, remote air and sea probing, etc. is clearly seen. A review of some recent advances in uv dye lasers is reviewed

  4. Structural, spectroscopic (FT-IR, NMR, UV-visible), nonlinear optical (NLO), cytotoxic and molecular docking studies of 4-nitro-isonitrosoacetophenone (ninapH) by DFT method

    Science.gov (United States)

    Kucuk, Ilhan; Kaya, Yunus; Kaya, A. Asli

    2017-07-01

    (4-Nitro-phenyl)-oxo-acetaldehyde oxime (ninapH) is a type of oxime, which has a oxime and α-carbonyl groups. This molecule has been synthesized from literature procedure. The structural properties and conformational behaviors were examined using the density functional theory (DFT) with the B3LYP method combined with the 6-311++G(d,p) basis set. As a result of the conformational studies, the most stable conformer was determined, and then this molecule was optimized with the same basis set. Comprehensive theoretical and experimental structural studies on the molecule have been carried out by FT-IR, NMR and UV-vis spectrometry. The calculated HOMO and LUMO energies show that charge transfer within the molecule. The first order hyperpolarizability and molecular electrostatic potential (MEP) were also performed. The thermodynamic properties (heat capacity, entropy, and enthalpy) of the ninapH have been calculated at different temperatures, 100-1000 K. In addition, the molecular docking studies have been performed with DNA and protein structures (downloaded from Protein Data Bank).

  5. Characterization of sp3 bond content of carbon films deposited by high power gas injection magnetron sputtering method by UV and VIS Raman spectroscopy

    Science.gov (United States)

    Zdunek, Krzysztof; Chodun, Rafał; Wicher, Bartosz; Nowakowska-Langier, Katarzyna; Okrasa, Sebastian

    2018-04-01

    This paper presents the results of investigations of carbon films deposited by a modified version of the magnetron sputtering method - HiPGIMS (High Power Gas Injection Magnetron Sputtering). In this experiment, the magnetron system with inversely polarized electrodes (sputtered cathode at ground potential and positively biased, spatially separated anode) was used. This arrangement allowed us to conduct the experiment using voltages ranging from 1 to 2 kV and a power supply system equipped with 25/50 μF capacitor battery. Carbon films were investigated by VIS/UV Raman spectroscopy. Sp3/sp2 bonding ratio was evaluated basing the elementary components of registered spectra. Our investigation showed that sp3 bond content increases with discharge power but up to specific value only. In extreme conditions of generating plasma impulses, we detected a reversed relation of the sp3/sp2 ratio. In our opinion, a energy of plasma pulse favors nucleation of a sp3 phase because of a relatively higher ionization state but in extreme cases the influence of energy is reversed.

  6. HPLC-UV Method for the Identification and Screening of Hydroquinone, Ethers of Hydroquinone and Corticosteroids Possibly Used as Skin-Whitening Agents in Illicit Cosmetic Products.

    Science.gov (United States)

    Gimeno, Pascal; Maggio, Annie-Françoise; Bancilhon, Marjorie; Lassu, Nelly; Gornes, Hervé; Brenier, Charlotte; Lempereur, Laurent

    2016-03-01

    Corticosteroids, hydroquinone and its ethers are regulated in cosmetics by the Regulation 1223/2009. As corticosteroids are forbidden to be used in cosmetics and cannot be present as contaminants or impurities, an identification of one of these illicit compounds deliberately introduced in these types of cosmetics is enough for market survey control. In order to quickly identify skin-whitening agents present in illegal cosmetics, this article proposes an HPLC-UV method for the identification and screening of hydroquinone, 3 ethers of hydroquinone and 39 corticosteroids that may be found in skin-whitening products. Two elution gradients were developed to separate all compounds. The main solvent gradient (A) allows the separation of 39 compounds among the 43 compounds considered in 50 min. Limits of detection on skin-whitening cosmetics are given. For compounds not separated, a complementary gradient elution (B) using the same solvents is proposed. Between 2004 and 2009, a market survey on "skin-whitening cosmetic" was performed on 150 samples and highlights that more than half of the products tested do not comply with the Cosmetic Regulation 1223/2009 (amending the Council Directive 76/768/EEC). © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Characterization of sp3 bond content of carbon films deposited by high power gas injection magnetron sputtering method by UV and VIS Raman spectroscopy.

    Science.gov (United States)

    Zdunek, Krzysztof; Chodun, Rafał; Wicher, Bartosz; Nowakowska-Langier, Katarzyna; Okrasa, Sebastian

    2018-04-05

    This paper presents the results of investigations of carbon films deposited by a modified version of the magnetron sputtering method - HiPGIMS (High Power Gas Injection Magnetron Sputtering). In this experiment, the magnetron system with inversely polarized electrodes (sputtered cathode at ground potential and positively biased, spatially separated anode) was used. This arrangement allowed us to conduct the experiment using voltages ranging from 1 to 2kV and a power supply system equipped with 25/50μF capacitor battery. Carbon films were investigated by VIS/UV Raman spectroscopy. Sp 3 /sp 2 bonding ratio was evaluated basing the elementary components of registered spectra. Our investigation showed that sp 3 bond content increases with discharge power but up to specific value only. In extreme conditions of generating plasma impulses, we detected a reversed relation of the sp 3 /sp 2 ratio. In our opinion, a energy of plasma pulse favors nucleation of a sp 3 phase because of a relatively higher ionization state but in extreme cases the influence of energy is reversed. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Synthesis of Fe-Doped ZnO Nanorods by Rapid Mixing Hydrothermal Method and Its Application for High Performance UV Photodetector

    Directory of Open Access Journals (Sweden)

    Chan Oeurn Chey

    2014-01-01

    Full Text Available We have successfully synthesized Fe-doped ZnO nanorods by a new and simple method in which the adopted approach is by using ammonia as a continuous source of OH- for hydrolysis instead of hexamethylenetetramine (HMT. The energy dispersive X-ray (EDX spectra revealed that the Fe peaks were presented in the grown Fe-doped ZnO nanorods samples and the X-ray photoelectron spectroscopy (XPS results suggested that Fe3+ is incorporated into the ZnO lattice. Structural characterization indicated that the Fe-doped ZnO nanorods grow along the c-axis with a hexagonal wurtzite structure and have single crystalline nature without any secondary phases or clusters of FeO or Fe3O4 observed in the samples. The Fe-doped ZnO nanorods showed room temperature (300 K ferromagnetic magnetization versus field (M-H hysteresis and the magnetization increases from 2.5 μemu to 9.1 μemu for Zn0.99Fe0.01O and Zn0.95Fe0.05O, respectively. Moreover, the fabricated Au/Fe-doped ZnO Schottky diode based UV photodetector achieved 2.33 A/W of responsivity and 5 s of time response. Compared to other Au/ZnO nanorods Schottky devices, the presented responsivity is an improvement by a factor of 3.9.

  9. Development and Validation of a Simple High Performance Liquid Chromatography/UV Method for Simultaneous Determination of Urinary Uric Acid, Hypoxanthine, and Creatinine in Human Urine

    Directory of Open Access Journals (Sweden)

    Nimanthi Wijemanne

    2018-01-01

    Full Text Available Uric acid and hypoxanthine are produced in the catabolism of purine. Abnormal urinary levels of these products are associated with many diseases and therefore it is necessary to have a simple and rapid method to detect them. Hence, we report a simple reverse phase high performance liquid chromatography (HPLC/UV technique, developed and validated for simultaneous analysis of uric acid, hypoxanthine, and creatinine in human urine. Urine was diluted appropriately and eluted with C-18 column 100 mm × 4.6 mm with a C-18 precolumn 25 mm × 4.6 mm in series. Potassium phosphate buffer (20 mM, pH 7.25 at a flow rate of 0.40 mL/min was employed as the solvent and peaks were detected at 235 nm. Tyrosine was used as the internal standard. The experimental conditions offered a good separation of analytes without interference of endogenous substances. The calibration curves were linear for all test compounds with a regression coefficient, r2>0.99. Uric acid, creatinine, tyrosine, and hypoxanthine were eluted at 5.2, 6.1, 7.2, and 8.3 min, respectively. Intraday and interday variability were less than 4.6% for all the analytes investigated and the recovery ranged from 98 to 102%. The proposed HPLC procedure is a simple, rapid, and low cost method with high accuracy with minimum use of organic solvents. This method was successfully applied for the determination of creatinine, hypoxanthine, and uric acid in human urine.

  10. Fast and sensitive HPLC/UV method for cefazolin quantification in plasma and subcutaneous tissue microdialysate of humans and rodents applied to pharmacokinetic studies in obese individuals.

    Science.gov (United States)

    Palma, Eduardo Celia; Laureano, João Victor; de Araújo, Bibiana Verlindo; Meinhardt, Nelson Guardiola; Stein, Airton Tetelbom; Dalla Costa, Teresa

    2018-04-14

    Antimicrobial prophylactic dosing of morbidly obese patients may differ from normal weighted individuals owing to alterations in drug tissue distribution. Drug subcutaneous tissue distribution can be investigated by microdialysis patients and animals. The need for cefazolin prophylactic dose adjustment in obese patients remains under discussion. The paper describes the validation of an HPLC-UV method for cefazolin quantification in plasma and microdialysate samples from clinical and pre-clinical studies. A C 18 column with an isocratic mobile phase was used for drug separation, with detection at 272 nm. Total and unbound cefazolin lower limit of quantitation was 5 μg/mL in human plasma, 2 μg/mL in rat plasma, and 0.5 and 0.025 μg/mL in human and rat microdialysate samples, respectively. The maximum intra- and inter-day imprecisions were 10.7 and 8.1%, respectively. The inaccuracy was <9.7%. The limit of quantitation imprecision and inaccuracy were < 15%. Cefazolin stability in the experimental conditions was confirmed. Cefazolin plasma concentrations and subcutaneous tissue penetration were determined by microdialysis in morbidly obese patients (2 g i.v. bolus) and diet-induced obese rats (30 mg/kg i.v. bolus) using the method. This method has the main advantages of easy plasma clean-up and practicability and has proven to be useful in cefazolin clinical and pre-clinical pharmacokinetic investigations. Copyright © 2018 John Wiley & Sons, Ltd.

  11. Zero crossing and ratio spectra derivative spectrophotometry for the dissolution tests of amlodipine and perindopril in their fixed dose formulations

    Directory of Open Access Journals (Sweden)

    Maczka Paulina

    2014-06-01

    Full Text Available Dissolution tests of amlodipine and perindopril from their fixed dose formulations were performed in 900 mL of phosphate buffer of pH 5.5 at 37°C using the paddle apparatus. Then, two simple and rapid derivative spectrophotometric methods were used for the quantitative measurements of amlodipine and perindopril. The first method was zero crossing first derivative spectrophotometry in which measuring of amplitudes at 253 nm for amlodipine and 229 nm for perindopril were used. The second method was ratio derivative spectrophotometry in which spectra of amlodipine over the linearity range were divided by one selected standard spectrum of perindopril and then amplitudes at 242 nm were measured. Similarly, spectra of perindopril were divided by one selected standard spectrum of amlodipine and then amplitudes at 298 nm were measured. Both of the methods were validated to meet official requirements and were demonstrated to be selective, precise and accurate. Since there is no official monograph for these drugs in binary formulations, the dissolution tests and quantification procedure presented here can be used as a quality control test for amlodipine and perindopril in respective dosage forms.

  12. Noise analysis for CCD-based ultraviolet and visible spectrophotometry.

    Science.gov (United States)

    Davenport, John J; Hodgkinson, Jane; Saffell, John R; Tatam, Ralph P

    2015-09-20

    We present the results of a detailed analysis of the noise behavior of two CCD spectrometers in common use, an AvaSpec-3648 CCD UV spectrometer and an Ocean Optics S2000 Vis spectrometer. Light sources used include a deuterium UV/Vis lamp and UV and visible LEDs. Common noise phenomena include source fluctuation noise, photoresponse nonuniformity, dark current noise, fixed pattern noise, and read noise. These were identified and characterized by varying light source, spectrometer settings, or temperature. A number of noise-limiting techniques are proposed, demonstrating a best-case spectroscopic noise equivalent absorbance of 3.5×10(-4)  AU for the AvaSpec-3648 and 5.6×10(-4)  AU for the Ocean Optics S2000 over a 30 s integration period. These techniques can be used on other CCD spectrometers to optimize performance.

  13. Application of wavelet and Fuorier transforms as powerful alternatives for derivative spectrophotometry in analysis of binary mixtures: A comparative study

    Science.gov (United States)

    Hassan, Said A.; Abdel-Gawad, Sherif A.

    2018-02-01

    Two signal processing methods, namely, Continuous Wavelet Transform (CWT) and the second was Discrete Fourier Transform (DFT) were introduced as alternatives to the classical Derivative Spectrophotometry (DS) in analysis of binary mixtures. To show the advantages of these methods, a comparative study was performed on a binary mixture of Naltrexone (NTX) and Bupropion (BUP). The methods were compared by analyzing laboratory prepared mixtures of the two drugs. By comparing performance of the three methods, it was proved that CWT and DFT methods are more efficient and advantageous in analysis of mixtures with overlapped spectra than DS. The three signal processing methods were adopted for the quantification of NTX and BUP in pure and tablet forms. The adopted methods were validated according to the ICH guideline where accuracy, precision and specificity were found to be within appropriate limits.

  14. Liquid-phase microextraction and fibre-optics-based cuvetteless CCD-array micro-spectrophotometry for trace analysis

    International Nuclear Information System (INIS)

    Sharma, Nisha; Pillai, Aradhana K.K.V.; Pathak, Neeraj; Jain, Archana; Verma, Krishna K.

    2009-01-01

    Liquid-phase microextraction (LPME) has been investigated for trace analysis in the present work in conjunction with fibre-optic-based micro-spectrophotometry which accommodates sample volume of 1 μL placed between the two ends of optical fibres. Methods have been evolved for the determination of (i) 1-100 μM and 0.5-20 μM of thiols by single drop microextraction (SDME) and LPME in 25 μL of the organic solvent, respectively, involving their reaction with the Ellman reagent and ion pair microextraction of thiolate ion formed; (ii) 70 μg to 7 mg L -1 of chlorine/chlorine dioxide by headspace in-drop reaction with alternative reagents, viz., mixed phenylhydrazine-4-sulphonic acid and N-(1-naphthyl)ethylenediamine dihydrochloride, o-dianisidine, o-tolidine, and N,N-diethyl-p-phenylenediamine; (iii) 0.2-4 mg L -1 of ammonia by reaction with 2,4-dinitro-1-fluorobenzene to give 2,4-dinitroaniline which was diazotized and coupled with 1-naphthylamine, the resulting dye was subjected to preconcentration by solid-phase extraction and LPME; and (iv) 25-750 μg L -1 of iodide/total iodine by oxidation of iodide by 2-iodosobenzoate, microextraction of iodine in organic solvent, and re-extraction into aqueous starch-iodide reagent drop held in the organic phase. LPME using 25-30 μL of organic solvent was found to produce more sensitive results than SDME. The cuvetteless spectrophotometry as used in combination with sample handling techniques produced limits of detection of analytes which were better than obtained by previously reported spectrophotometry.

  15. The analysis, by atomic-absorption spectrophotometry, of matte-leach residues

    International Nuclear Information System (INIS)

    Mallett, R.C.; Ring, E.J.; Middleton, H.R.; Dubois, M.

    1973-01-01

    Alternative methods for the analysis of matte-leach residues by atomic-absorption spectrophotometry were investigated. For the determination of the platinum-group metals, gold, and certain of the base metals, a fusion with sodium peroxide, followed by the separation of gold by reverse-phase chromatography and of the platinum-group metals by ion-exchange, is proposed. The noble metals are then determined in a solution that is free of most base metals including the sodium present as a result of the fusion. Copper, nickel, iron, calcium, magnesium, and aluminium can be determined after they have been removed from the ion-exchange column. Arsenic, selenium, tellurium, bismuth, tin, silver, lead, manganese, zinc, and cobalt can be determined in a separate sample after dissolution by a sealed-tube method. This is also an alternative method for the determination of copper, nickel, and iron. Chromium is determined separately after fusion with sodium peroxide, and silver can also be determined in this way. The laboratory method for these procedures is given as an appendix [af

  16. The determination, by atomic-absorption spectrophotometry, of impurities in manganese dioxide

    International Nuclear Information System (INIS)

    Balaes, G.E.E.; Robert, R.V.D.

    1981-01-01

    This report describes various methods for the determination of impurities in electrolytic manganese dioxide by atomic-absorption spectrophotometry (AAS). The sample is dissolved in a mixture of acids, any residue being ignited and retreated with acid. Several AAS methods were applied so that the analysis required to meet the specifications could be attained. These involved conventional flame AAS, AAS with electrothermal atomization (ETA), hydride generation coupled with AAS, and cold-vapour AAS. Of the elements examined, copper, iron, zinc, and lead can be determined direct with confidence with or without corrections based on recoveries obtained from spiked solutions. Nickel can be determined direct by use of the method of standard additions, and copper, nickel, and lead by ETA with the method of standard additions. Arsenic and antimony are determined by hydride generation coupled with AAS, and mercury by cold-vapour AAS. The precision of analysis (relative standard deviation) is generally less than 0,050. Values were obtained for aluminium, molybdenum, magnesium, sodium, copper, chromium, and cadmium, but the accuracy of these determinations has not been fully established

  17. H II region in NGC 6744: Spectrophotometry and chemical abundances

    International Nuclear Information System (INIS)

    Talent, D.L.

    1982-01-01

    Spectrophotometry of emission lines in the lambdalambda3700--6800 spectral range is presented for An H II region in an outer arm of NGC6744, a southern hemisphere galaxy of type SAB(r)bc II. The electron temperature, derived from the [O III] lines and assuming N/sub e/ = 100 cm -3 , was found to be 9,630 +- 450 K. Ionic abundances, derived in the usual fashion from the measured line strengths, were corrected to total relative number abundances by application of the standard ionization correction factor (ICF) scheme and by comparison to models. The derived abundances, relative to log Hequivalent12.00, are log He = 10.96 +- 0.06, log N = 7.34 +- 0.26, log O log O = 8.44 +- 0.10, log Ne = 7.80 +- 0.16, and log S = 6.75 +- 0.28. The NGC 6744 H II region abundances, and various ratios, are compared to similar data for H II regions in the SMC, LMC, and the Perseus arm of the Galaxy,. From the comparison it is suggested that the histories of nucleosynthesis in the outer regions of NGC 6744 and the Galaxy could have been quite similar

  18. Spectrophotometry of the double QSO, 0957+561

    International Nuclear Information System (INIS)

    Wills, B.J.; Wills, D.

    1980-01-01

    We report new spectrophotometry of the double QSO, 0957+561, and show that the absorption line region in each light path is very similar in redshift (Δv +- 14 km s -1 rms), in column density of Fe + (approx.3 x 10 14 cm -2 ), and in velocity dispersion (approx.40 km s -1 ). The simplest interpretation of these results is a very massive object deflecting the light from a more distant QSO. Based on this hypothesis we find that the differences between the emission line and continuum spectra may be explained by differential reddening, implying a reddening-corrected flux ratio B/Aapprox. =2--4. This ratio is different from that found at radio wavelengths (0.7 at 6 cm), but can be explained, based on the gravitational lens hypothesis, by different flux variability at radio and optical wavelengths; however, we have found no evidence for optical variability. Another difficulty may be that a point-mass gravitational lens would need to have a mass-to-light ratio greater than 1000, if it is closer than z=0.4; at larger distances its mass would be very large (approx.10 14 M/sub sun/ at z=1.2). Observations obtained so far might be explained if two massive QSOs are actually closer together than appear to be, as a result of mutual gravitational deflection of the light. 1

  19. A new dyed ECE track identification method for nuclear particle detection

    International Nuclear Information System (INIS)

    Sohrabi, M.; Bojd, S.S.

    1990-01-01

    A new procedure for obtaining highly contrasted red-dyed electrochemically etched recoil tracks in polymers such as polycarbonate (PC) and CR-39 has been successfully developed for spectrophotometry as applied to neutron dosimetry. The principal rationale in this method has been the provision of highly contrasted, photon-absorbing, large, dyed recoil tracks in an unaffected bulk material. The method consists of: (a) exposing the polymer to charged particles or neutrons; (b) electrochemical etching of the tracks; (c) acid sensitization; (d) dyeing with an appropriate dye. By investigation of the type, concentration, duration and temperature of the acid and the dye, optimized values of 20% by weight acrylic acid at 75 0 C for 3.5 h for sensitization, and 3% by weight eosin bluish dye at 95 0 C for 4 h for dyeing, provided a nearly 100% dyed-track efficiency. Spectrophotometry by UV and infrared radiation track counting, and optical densitometry were applied to the dyed samples. The results have shown some promise for UV absorbance measurements in routine large-scale applications. In this paper, the results of optimization studies and preliminary application of the technique to neutron dosimetry are presented and discussed. (author)

  20. Validation of ultraviolet method to determine serum phosphorus level

    International Nuclear Information System (INIS)

    Garcia Borges, Lisandra; Perez Prieto, Teresa Maria; Valdes Diez, Lilliam

    2009-01-01

    Validation of a spectrophotometry method applicable in clinic labs was proposed to analytical assessment of serum phosphates using a kit UV-phosphorus of domestic production from 'Carlos J. Finlay' Biologics Production Enterprise (Havana, Cuba). Analysis method was based on phosphorus reaction to ammonium molybdenum to acid pH to creating a measurable complex to 340 nm. Specificity and precision were measured considering the method strength, linearity, accuracy and sensitivity. Analytical method was linear up to 4,8 mmol/L, precise (CV 30 .999) during clinical interest concentration interval where there were not interferences by matrix. Detection limit values were of 0.037 mmol/L and of quantification of 0.13 mmol/L both were satisfactory for product use