WorldWideScience

Sample records for method simple cumulative

  1. Cumulative query method for influenza surveillance using search engine data.

    Science.gov (United States)

    Seo, Dong-Woo; Jo, Min-Woo; Sohn, Chang Hwan; Shin, Soo-Yong; Lee, JaeHo; Yu, Maengsoo; Kim, Won Young; Lim, Kyoung Soo; Lee, Sang-Il

    2014-12-16

    Internet search queries have become an important data source in syndromic surveillance system. However, there is currently no syndromic surveillance system using Internet search query data in South Korea. The objective of this study was to examine correlations between our cumulative query method and national influenza surveillance data. Our study was based on the local search engine, Daum (approximately 25% market share), and influenza-like illness (ILI) data from the Korea Centers for Disease Control and Prevention. A quota sampling survey was conducted with 200 participants to obtain popular queries. We divided the study period into two sets: Set 1 (the 2009/10 epidemiological year for development set 1 and 2010/11 for validation set 1) and Set 2 (2010/11 for development Set 2 and 2011/12 for validation Set 2). Pearson's correlation coefficients were calculated between the Daum data and the ILI data for the development set. We selected the combined queries for which the correlation coefficients were .7 or higher and listed them in descending order. Then, we created a cumulative query method n representing the number of cumulative combined queries in descending order of the correlation coefficient. In validation set 1, 13 cumulative query methods were applied, and 8 had higher correlation coefficients (min=.916, max=.943) than that of the highest single combined query. Further, 11 of 13 cumulative query methods had an r value of ≥.7, but 4 of 13 combined queries had an r value of ≥.7. In validation set 2, 8 of 15 cumulative query methods showed higher correlation coefficients (min=.975, max=.987) than that of the highest single combined query. All 15 cumulative query methods had an r value of ≥.7, but 6 of 15 combined queries had an r value of ≥.7. Cumulative query method showed relatively higher correlation with national influenza surveillance data than combined queries in the development and validation set.

  2. A method proposal for cumulative environmental impact assessment based on the landscape vulnerability evaluation

    International Nuclear Information System (INIS)

    Pavlickova, Katarina; Vyskupova, Monika

    2015-01-01

    Cumulative environmental impact assessment deals with the occasional use in practical application of environmental impact assessment process. The main reasons are the difficulty of cumulative impact identification caused by lack of data, inability to measure the intensity and spatial effect of all types of impacts and the uncertainty of their future evolution. This work presents a method proposal to predict cumulative impacts on the basis of landscape vulnerability evaluation. For this purpose, qualitative assessment of landscape ecological stability is conducted and major vulnerability indicators of environmental and socio-economic receptors are specified and valuated. Potential cumulative impacts and the overall impact significance are predicted quantitatively in modified Argonne multiple matrixes while considering the vulnerability of affected landscape receptors and the significance of impacts identified individually. The method was employed in the concrete environmental impact assessment process conducted in Slovakia. The results obtained in this case study reflect that this methodology is simple to apply, valid for all types of impacts and projects, inexpensive and not time-consuming. The objectivity of the partial methods used in this procedure is improved by quantitative landscape ecological stability evaluation, assignment of weights to vulnerability indicators based on the detailed characteristics of affected factors, and grading impact significance. - Highlights: • This paper suggests a method proposal for cumulative impact prediction. • The method includes landscape vulnerability evaluation. • The vulnerability of affected receptors is determined by their sensitivity. • This method can increase the objectivity of impact prediction in the EIA process

  3. Cumulative Risk Assessment Toolbox: Methods and Approaches for the Practitioner

    Directory of Open Access Journals (Sweden)

    Margaret M. MacDonell

    2013-01-01

    Full Text Available The historical approach to assessing health risks of environmental chemicals has been to evaluate them one at a time. In fact, we are exposed every day to a wide variety of chemicals and are increasingly aware of potential health implications. Although considerable progress has been made in the science underlying risk assessments for real-world exposures, implementation has lagged because many practitioners are unaware of methods and tools available to support these analyses. To address this issue, the US Environmental Protection Agency developed a toolbox of cumulative risk resources for contaminated sites, as part of a resource document that was published in 2007. This paper highlights information for nearly 80 resources from the toolbox and provides selected updates, with practical notes for cumulative risk applications. Resources are organized according to the main elements of the assessment process: (1 planning, scoping, and problem formulation; (2 environmental fate and transport; (3 exposure analysis extending to human factors; (4 toxicity analysis; and (5 risk and uncertainty characterization, including presentation of results. In addition to providing online access, plans for the toolbox include addressing nonchemical stressors and applications beyond contaminated sites and further strengthening resource accessibility to support evolving analyses for cumulative risk and sustainable communities.

  4. Measurement of four-particle cumulants and symmetric cumulants with subevent methods in small collision systems with the ATLAS detector

    CERN Document Server

    Derendarz, Dominik; The ATLAS collaboration

    2018-01-01

    Measurements of symmetric cumulants SC(n,m)=⟨v2nv2m⟩−⟨v2n⟩⟨v2m⟩ for (n,m)=(2,3) and (2,4) and asymmetric cumulant AC(n) are presented in pp, p+Pb and peripheral Pb+Pb collisions at various collision energies, aiming to probe the long-range collective nature of multi-particle production in small systems. Results are obtained using the standard cumulant method, as well as the two-subevent and three-subevent cumulant methods. Results from the standard method are found to be strongly biased by non-flow correlations as indicated by strong sensitivity to the chosen event class definition. A systematic reduction of non-flow effects is observed when using the two-subevent method and the results become independent of event class definition when the three-subevent method is used. The measured SC(n,m) shows an anti-correlation between v2 and v3, and a positive correlation between v2 and v4. The magnitude of SC(n,m) is constant with Nch in pp collisions, but increases with Nch in p+Pb and Pb+Pb collisions. ...

  5. Estimation of Cumulative Absolute Velocity using Empirical Green's Function Method

    International Nuclear Information System (INIS)

    Park, Dong Hee; Yun, Kwan Hee; Chang, Chun Joong; Park, Se Moon

    2009-01-01

    In recognition of the needs to develop a new criterion for determining when the OBE (Operating Basis Earthquake) has been exceeded at nuclear power plants, Cumulative Absolute Velocity (CAV) was introduced by EPRI. The concept of CAV is the area accumulation with the values more than 0.025g occurred during every one second. The equation of the CAV is as follows. CAV = ∫ 0 max |a(t)|dt (1) t max = duration of record, a(t) = acceleration (>0.025g) Currently, the OBE exceedance criteria in Korea is Peak Ground Acceleration (PGA, PGA>0.1g). When Odesan earthquake (M L =4.8, January 20th, 2007) and Gyeongju earthquake (M L =3.4, June 2nd, 1999) were occurred, we have had already experiences of PGA greater than 0.1g that did not even cause any damage to the poorly-designed structures nearby. This moderate earthquake has motivated Korea to begin the use of the CAV for OBE exceedance criteria for NPPs. Because the present OBE level has proved itself to be a poor indicator for small-to-moderate earthquakes, for which the low OBE level can cause an inappropriate shut down the plant. A more serious possibility is that this scenario will become a reality at a very high level. Empirical Green's Function method was a simulation technique which can estimate the CAV value and it is hereby introduced

  6. Substoichiometric method in the simple radiometric analysis

    International Nuclear Information System (INIS)

    Ikeda, N.; Noguchi, K.

    1979-01-01

    The substoichiometric method is applied to simple radiometric analysis. Two methods - the standard reagent method and the standard sample method - are proposed. The validity of the principle of the methods is verified experimentally in the determination of silver by the precipitation method, or of zinc by the ion-exchange or solvent-extraction method. The proposed methods are simple and rapid compared with the conventional superstoichiometric method. (author)

  7. Wrist arthrography: a simple method

    Energy Technology Data Exchange (ETDEWEB)

    Berna-Serna, Juan D.; Reus, Manuel; Alonso, Jose [Virgen de la Arrixaca University Hospital, Department of Radiology, El Palmar (Murcia) (Spain); Martinez, Francisco; Domenech-Ratto, Gines [University of Murcia, Department of Human Anatomy, Faculty of Medicine, Murcia (Spain)

    2006-02-01

    A technique of wrist arthrography is presented using an adhesive marker-plate with radiopaque coordinates to identify precisely sites for puncture arthrography of the wrist and to obviate the need for fluoroscopic guidance. Radiocarpal joint arthrography was performed successfully in all 24 cases, 14 in the cadaveric wrists and 10 in the live patients. The arthrographic procedure described in this study is simple, safe, and rapid, and has the advantage of precise localisation of the site for puncture without need for fluoroscopic guidance. (orig.)

  8. Methadone radioimmunoassay: two simple methods

    International Nuclear Information System (INIS)

    Robinson, K.; Smith, R.N.

    1983-01-01

    Two simple and economical radioimmunoassays for methadone in blood or urine are described. Haemolysis, decomposition, common anticoagulants and sodium fluoride do not affect the results. One assay used commercially-available [1- 3 H](-)-methadone hydrobromide as the label, while the other uses a radioiodinated conjugate of 4-dimethylamino-2,2-diphenylpentanoic acid and L-tyrosine methyl ester. A commercially-available antiserum is used in both assays. Normethadone and α-methadol cross-react to a small extent with the antiserum while methadone metabolites, dextropropoxyphene, dipipanone and phenadoxone have negligible cross-reactivities. The 'cut-offs' of the two assays as described are 30 and 33 ng ml -1 for blood, and 24 and 21 ng ml -1 for urine. The assay using the radioiodinated conjugate can be made more sensitive if required by increasing the specific activity of the label. (author)

  9. 78 FR 25440 - Request for Information and Citations on Methods for Cumulative Risk Assessment

    Science.gov (United States)

    2013-05-01

    ... Citations on Methods for Cumulative Risk Assessment AGENCY: Office of the Science Advisor, Environmental... influence exposures, dose-response or risk/hazard posed by environmental contaminant exposures, and methods... who wish to receive further information about submitting information on methods for cumulative risk...

  10. Ecosystem assessment methods for cumulative effects at the regional scale

    International Nuclear Information System (INIS)

    Hunsaker, C.T.

    1989-01-01

    Environmental issues such as nonpoint-source pollution, acid rain, reduced biodiversity, land use change, and climate change have widespread ecological impacts and require an integrated assessment approach. Since 1978, the implementing regulations for the National Environmental Policy Act (NEPA) have required assessment of potential cumulative environmental impacts. Current environmental issues have encouraged ecologists to improve their understanding of ecosystem process and function at several spatial scales. However, management activities usually occur at the local scale, and there is little consideration of the potential impacts to the environmental quality of a region. This paper proposes that regional ecological risk assessment provides a useful approach for assisting scientists in accomplishing the task of assessing cumulative impacts. Critical issues such as spatial heterogeneity, boundary definition, and data aggregation are discussed. Examples from an assessment of acidic deposition effects on fish in Adirondack lakes illustrate the importance of integrated data bases, associated modeling efforts, and boundary definition at the regional scale

  11. Signal anomaly detection using modified CUSUM [cumulative sum] method

    International Nuclear Information System (INIS)

    Morgenstern, V.; Upadhyaya, B.R.; Benedetti, M.

    1988-01-01

    An important aspect of detection of anomalies in signals is the identification of changes in signal behavior caused by noise, jumps, changes in band-width, sudden pulses and signal bias. A methodology is developed to identify, isolate and characterize these anomalies using a modification of the cumulative sum (CUSUM) approach. The new algorithm performs anomaly detection at three levels and is implemented on a general purpose computer. 7 refs., 4 figs

  12. A damage cumulation method for crack initiation prediction under non proportional loading and overloading

    International Nuclear Information System (INIS)

    Taheri, S.

    1992-04-01

    For a sequence of constant amplitude cyclic loading containing overloads, we propose a method for damage cumulation in non proportional loading. This method uses as data cyclic stabilized states at non proportional loading and initiation or fatigue curve in uniaxial case. For that, we take into account the dependence of Cyclic Strain Stress Curves (C.S.S.C.) and mean cell size on prehardening and we define a stabilized uniaxial state cyclically equivalent to a non proportional stabilized state through a family of C.S.S.C. Although simple assumptions like linear damage function and linear cumulation is used we obtain a sequence effect for difficult cross slip materials as 316 stainless steel, but the Miner rule for easy cross-slip materials. We show then differences between a load-controlled test and a strain controlled test: for a 316 stainless steel in a load controlled test, the non proportional loading at each cycle is less damaging than the uniaxial one for the same equivalent stress, while the result is opposite in a strain controlled test. We show also that an overloading retards initiation in a load controlled test while it accelerates initiation in a strain controlled test. (author). 26 refs., 8 figs

  13. A Simple Preparation Method for Diphosphoimidazole

    DEFF Research Database (Denmark)

    Rosenberg, T.

    1964-01-01

    A simple method for the preparation of diphosphoimidazole is presented that involves direct phosphorylation of imidazole by phosphorus oxychloride in alkaline aqueous solution. Details are given on the use of diphosphoimidazole in preparing sodium phosphoramidate and certain phosphorylated amino...

  14. Simple Calculation Programs for Biology Immunological Methods

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Simple Calculation Programs for Biology Immunological Methods. Computation of Ab/Ag Concentration from EISA data. Graphical Method; Raghava et al., 1992, J. Immuno. Methods 153: 263. Determination of affinity of Monoclonal Antibody. Using non-competitive ...

  15. Sparse Method for Direction of Arrival Estimation Using Denoised Fourth-Order Cumulants Vector.

    Science.gov (United States)

    Fan, Yangyu; Wang, Jianshu; Du, Rui; Lv, Guoyun

    2018-06-04

    Fourth-order cumulants (FOCs) vector-based direction of arrival (DOA) estimation methods of non-Gaussian sources may suffer from poor performance for limited snapshots or difficulty in setting parameters. In this paper, a novel FOCs vector-based sparse DOA estimation method is proposed. Firstly, by utilizing the concept of a fourth-order difference co-array (FODCA), an advanced FOCs vector denoising or dimension reduction procedure is presented for arbitrary array geometries. Then, a novel single measurement vector (SMV) model is established by the denoised FOCs vector, and efficiently solved by an off-grid sparse Bayesian inference (OGSBI) method. The estimation errors of FOCs are integrated in the SMV model, and are approximately estimated in a simple way. A necessary condition regarding the number of identifiable sources of our method is presented that, in order to uniquely identify all sources, the number of sources K must fulfill K ≤ ( M 4 - 2 M 3 + 7 M 2 - 6 M ) / 8 . The proposed method suits any geometry, does not need prior knowledge of the number of sources, is insensitive to associated parameters, and has maximum identifiability O ( M 4 ) , where M is the number of sensors in the array. Numerical simulations illustrate the superior performance of the proposed method.

  16. Estimation of cortical silent period following transcranial magnetic stimulation using a computerised cumulative sum method.

    Science.gov (United States)

    King, Nicolas K K; Kuppuswamy, Annapoorna; Strutton, Paul H; Davey, Nick J

    2006-01-15

    The cortical silent period (CSP) following transcranial magnetic stimulation (TMS) of the motor cortex can be used to measure intra-cortical inhibition and changes in a number of important pathologies affecting the central nervous system. The main drawback of this technique has been the difficulty in accurately identifying the onset and offset of the cortical silent period leading to inter-observer variability. We developed an automated method based on the cumulative sum (Cusum) technique to improve the determination of the duration and area of the cortical silent period. This was compared with experienced raters and two other automated methods. We showed that the automated Cusum method reliably correlated with the experienced raters for both duration and area of CSP. Compared with the automated methods, the Cusum also showed the strongest correlation with the experienced raters. Our results show the Cusum method to be a simple, graphical and powerful method of detecting low-intensity CSP that can be easily automated using standard software.

  17. Simple Calculation Programs for Biology Other Methods

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Simple Calculation Programs for Biology Other Methods. Hemolytic potency of drugs. Raghava et al., (1994) Biotechniques 17: 1148. FPMAP: methods for classification and identification of microorganisms 16SrRNA. graphical display of restriction and fragment map of ...

  18. Simple gas chromatographic method for furfural analysis.

    Science.gov (United States)

    Gaspar, Elvira M S M; Lopes, João F

    2009-04-03

    A new, simple, gas chromatographic method was developed for the direct analysis of 5-hydroxymethylfurfural (5-HMF), 2-furfural (2-F) and 5-methylfurfural (5-MF) in liquid and water soluble foods, using direct immersion SPME coupled to GC-FID and/or GC-TOF-MS. The fiber (DVB/CAR/PDMS) conditions were optimized: pH effect, temperature, adsorption and desorption times. The method is simple and accurate (RSDfurfurals will contribute to characterise and quantify their presence in the human diet.

  19. Simple method for calculating island widths

    International Nuclear Information System (INIS)

    Cary, J.R.; Hanson, J.D.; Carreras, B.A.; Lynch, V.E.

    1989-01-01

    A simple method for calculating magnetic island widths has been developed. This method uses only information obtained from integrating along the closed field line at the island center. Thus, this method is computationally less intensive than the usual method of producing surfaces of section of sufficient detail to locate and resolve the island separatrix. This method has been implemented numerically and used to analyze the buss work islands of ATF. In this case the method proves to be accurate to at least within 30%. 7 refs

  20. [Analgesic quality in a postoperative pain service: continuous assessment with the cumulative sum (cusum) method].

    Science.gov (United States)

    Baptista Macaroff, W M; Castroman Espasandín, P

    2007-01-01

    The aim of this study was to assess the cumulative sum (cusum) method for evaluating the performance of our hospital's acute postoperative pain service. The period of analysis was 7 months. Analgesic failure was defined as a score of 3 points or more on a simple numerical scale. Acceptable failure (p0) was set at 20% of patients upon admission to the postanesthetic recovery unit and at 7% 24 hours after surgery. Unacceptable failure was set at double the p0 rate at each time (40% and 14%, respectively). The unit's patient records were used to generate a cusum graph for each evaluation. Nine hundred four records were included. The rate of failure was 31.6% upon admission to the unit and 12.1% at the 24-hour postoperative assessment. The curve rose rapidly to the value set for p0 at both evaluation times (n = 14 and n = 17, respectively), later leveled off, and began to fall after 721 and 521 cases, respectively. Our study shows the efficacy of the cusum method for monitoring a proposed quality standard. The graph also showed periods of suboptimal performance that would not have been evident from analyzing the data en block. Thus the cusum method would facilitate rapid detection of periods in which quality declines.

  1. Cumulative Mass and NIOSH Variable Lifting Index Method for Risk Assessment: Possible Relations.

    Science.gov (United States)

    Stucchi, Giulia; Battevi, Natale; Pandolfi, Monica; Galinotti, Luca; Iodice, Simona; Favero, Chiara

    2018-02-01

    Objective The aim of this study was to explore whether the Variable Lifting Index (VLI) can be corrected for cumulative mass and thus test its efficacy in predicting the risk of low-back pain (LBP). Background A validation study of the VLI method was published in this journal reporting promising results. Although several studies highlighted a positive correlation between cumulative load and LBP, cumulative mass has never been considered in any of the studies investigating the relationship between manual material handling and LBP. Method Both VLI and cumulative mass were calculated for 2,374 exposed subjects using a systematic approach. Due to high variability of cumulative mass values, a stratification within VLI categories was employed. Dummy variables (1-4) were assigned to each class and used as a multiplier factor for the VLI, resulting in a new index (VLI_CMM). Data on LBP were collected by occupational physicians at the study sites. Logistic regression was used to estimate the risk of acute LBP within levels of risk exposure when compared with a control group formed by 1,028 unexposed subjects. Results Data showed greatly variable values of cumulative mass across all VLI classes. The potential effect of cumulative mass on damage emerged as not significant ( p value = .6526). Conclusion When comparing VLI_CMM with raw VLI, the former failed to prove itself as a better predictor of LBP risk. Application To recognize cumulative mass as a modifier, especially for lumbar degenerative spine diseases, authors of future studies should investigate potential association between the VLI and other damage variables.

  2. A simple method for α determination

    International Nuclear Information System (INIS)

    Ho Manh Dung; Seung Yeon Cho

    2003-01-01

    The a term is a primary parameter that is used to indicate the deviation of the epithermal neutron distribution in the k 0 -standardization method of neutron activation analysis, k 0 -NAA. The calculation of a using a mathematical procedure is a challenge for some researchers. The calculation of a by the 'bare-triple monitor' method is possible using the dedicated commercial software KAYZERO R /SOLCOI R . However, when this software is not available in the laboratory it is possible to carry out the calculation of a applying a simple iterative linear regression using any spreadsheets. This approach is described. The experimental data used in the example were obtained by the irradiation of a set of suitable monitors in the NAA no.1 irradiation channel of the HANARO research reactor (KAERI, Korea). The results obtained by this iterative linear regression method agree well with the results calculated by the validated mathematical method. (author)

  3. Quantitative methods for analysing cumulative effects on fish migration success: a review.

    Science.gov (United States)

    Johnson, J E; Patterson, D A; Martins, E G; Cooke, S J; Hinch, S G

    2012-07-01

    It is often recognized, but seldom addressed, that a quantitative assessment of the cumulative effects, both additive and non-additive, of multiple stressors on fish survival would provide a more realistic representation of the factors that influence fish migration. This review presents a compilation of analytical methods applied to a well-studied fish migration, a more general review of quantitative multivariable methods, and a synthesis on how to apply new analytical techniques in fish migration studies. A compilation of adult migration papers from Fraser River sockeye salmon Oncorhynchus nerka revealed a limited number of multivariable methods being applied and the sub-optimal reliance on univariable methods for multivariable problems. The literature review of fisheries science, general biology and medicine identified a large number of alternative methods for dealing with cumulative effects, with a limited number of techniques being used in fish migration studies. An evaluation of the different methods revealed that certain classes of multivariable analyses will probably prove useful in future assessments of cumulative effects on fish migration. This overview and evaluation of quantitative methods gathered from the disparate fields should serve as a primer for anyone seeking to quantify cumulative effects on fish migration survival. © 2012 The Authors. Journal of Fish Biology © 2012 The Fisheries Society of the British Isles.

  4. Simple Synthesis Method for Alumina Nanoparticle

    Directory of Open Access Journals (Sweden)

    Daniel Damian

    2017-11-01

    Full Text Available Globally, the human population steady increase, expansion of urban areas, excessive industrialization including in agriculture, caused not only decrease to depletion of non-renewable resources, a rapid deterioration of the environment with negative impact on water quality, soil productivity and of course quality of life in general. This paper aims to prepare size controlled nanoparticles of aluminum oxide using a simple synthesis method. The morphology and dimensions of nanomaterial was investigated using modern analytical techniques: SEM/EDAX and XRD spectroscopy.

  5. A new method to cluster genomes based on cumulative Fourier power spectrum.

    Science.gov (United States)

    Dong, Rui; Zhu, Ziyue; Yin, Changchuan; He, Rong L; Yau, Stephen S-T

    2018-06-20

    Analyzing phylogenetic relationships using mathematical methods has always been of importance in bioinformatics. Quantitative research may interpret the raw biological data in a precise way. Multiple Sequence Alignment (MSA) is used frequently to analyze biological evolutions, but is very time-consuming. When the scale of data is large, alignment methods cannot finish calculation in reasonable time. Therefore, we present a new method using moments of cumulative Fourier power spectrum in clustering the DNA sequences. Each sequence is translated into a vector in Euclidean space. Distances between the vectors can reflect the relationships between sequences. The mapping between the spectra and moment vector is one-to-one, which means that no information is lost in the power spectra during the calculation. We cluster and classify several datasets including Influenza A, primates, and human rhinovirus (HRV) datasets to build up the phylogenetic trees. Results show that the new proposed cumulative Fourier power spectrum is much faster and more accurately than MSA and another alignment-free method known as k-mer. The research provides us new insights in the study of phylogeny, evolution, and efficient DNA comparison algorithms for large genomes. The computer programs of the cumulative Fourier power spectrum are available at GitHub (https://github.com/YaulabTsinghua/cumulative-Fourier-power-spectrum). Copyright © 2018. Published by Elsevier B.V.

  6. Evaluation of a post-analysis method for cumulative dose distribution in stereotactic body radiotherapy

    International Nuclear Information System (INIS)

    Imae, Toshikazu; Takenaka, Shigeharu; Saotome, Naoya

    2016-01-01

    The purpose of this study was to evaluate a post-analysis method for cumulative dose distribution in stereotactic body radiotherapy (SBRT) using volumetric modulated arc therapy (VMAT). VMAT is capable of acquiring respiratory signals derived from projection images and machine parameters based on machine logs during VMAT delivery. Dose distributions were reconstructed from the respiratory signals and machine parameters in the condition where respiratory signals were without division, divided into 4 and 10 phases. The dose distribution of each respiratory phase was calculated on the planned four-dimensional CT (4DCT). Summation of the dose distributions was carried out using deformable image registration (DIR), and cumulative dose distributions were compared with those of the corresponding plans. Without division, dose differences between cumulative distribution and plan were not significant. In the condition Where respiratory signals were divided, dose differences were observed over dose in cranial region and under dose in caudal region of planning target volume (PTV). Differences between 4 and 10 phases were not significant. The present method Was feasible for evaluating cumulative dose distribution in VMAT-SBRT using 4DCT and DIR. (author)

  7. A spot-matching method using cumulative frequency matrix in 2D gel images

    Science.gov (United States)

    Han, Chan-Myeong; Park, Joon-Ho; Chang, Chu-Seok; Ryoo, Myung-Chun

    2014-01-01

    A new method for spot matching in two-dimensional gel electrophoresis images using a cumulative frequency matrix is proposed. The method improves on the weak points of the previous method called ‘spot matching by topological patterns of neighbour spots’. It accumulates the frequencies of neighbour spot pairs produced through the entire matching process and determines spot pairs one by one in order of higher frequency. Spot matching by frequencies of neighbour spot pairs shows a fairly better performance. However, it can give researchers a hint for whether the matching results can be trustworthy or not, which can save researchers a lot of effort for verification of the results. PMID:26019609

  8. Validity of the cumulant method for a pulse nonlinear Kerr oscillator

    International Nuclear Information System (INIS)

    Grygiel, K.; Leonski, W.; Szlachetka, P.

    1998-01-01

    We study the dynamics of an anharmonic oscillator driven by a train of pulses. The cumulant expansion and quantum evolution operator approaches are presented and compared. The modifications introduced by quantum mechanics into the dynamics of classical systems which manifest chaos are a problem of great importance. It is known that quantization modifies the dynamics of classical system is usually studied by means of the equation for the Wigner function derived from the quantum Liouville equation. In Wigner's formulation of quantum mechanics we treat a quantum system in a 'classical way' including all their quantum features. And what is more, we can contrast the quantum and classical dynamics within the framework of one formalism. The problem is, that the equations for the Wigner functions are mathematically cumbersome and their analytic solutions for most nonlinear systems are unknown. However, instead of the equation for the Wigner function we can use the set of equations for statistical moments generated by our equation for the Wigner function. It is obvious that in this approach a quantum system is governed by an infinite set of equations. Therefore, for numerical reasons the set of equations for statistical moments has to be truncated at a finite number, which means approximating it. It is known that first cumulant approximation represents the classical dynamics. The second cumulant approximation adds the first quantum corrections to the classical dynamics. In this paper we compare some aspects of the cumulant method and the method used by Leonski and Tanas to study an anharmonic oscillator driven by a train of pulses. The Kerr oscillator model is the same ad that is discussed in an earlier paper albeit without the damping mechanism

  9. Measurement of multi-particle azimuthal correlations with the subevent cumulant method with the ATLAS detector

    CERN Document Server

    Zhou, Mingliang; The ATLAS collaboration

    2017-01-01

    The measurement of four-particle cumulant and anisotropic elliptic flow coefficient for the second harmonic, $c_{2}\\{4\\}$ and $v_{2}\\{4\\}$, are presented using $pp$ data at $\\sqrt{s}=5.02$ and $\\sqrt{s}=13$ TeV, and $p+$Pb data at $\\sqrt{s_{\\text{NN}}}=5.02$ TeV. These measurements aim to assess collective nature of multi-particle production. While collectivity is well established in $p$+Pb and Pb+Pb collisions, because of larger non-flow contributions, its evidence in $pp$ collisions is contested. The values of $c_{2}\\{4\\}$ are calculated using the standard cumulant method and recently proposed two and three subevent methods, which can further suppress the non-flow contributions in small systems. In these collisions systems, the three subevent method gives a negative $c_{2}\\{4\\}$, and thus a well-defined $v_{2}\\{4\\}$. The magnitude of $c_{2}\\{4\\}$ is found to be nearly independent of $\\langle N_{\\text{ch}} \\rangle$ and third harmonic $c_{3}\\{4\\}$ is consistent with 0. $v_{2}\\{4\\}$ is found to be smaller than...

  10. A method for the calculation of the cumulative failure probability distribution of complex repairable systems

    International Nuclear Information System (INIS)

    Caldarola, L.

    1976-01-01

    A method is proposed for the analytical evaluation of the cumulative failure probability distribution of complex repairable systems. The method is based on a set of integral equations each one referring to a specific minimal cut set of the system. Each integral equation links the unavailability of a minimal cut set to its failure probability density distribution and to the probability that the minimal cut set is down at the time t under the condition that it was down at time t'(t'<=t). The limitations for the applicability of the method are also discussed. It has been concluded that the method is applicable if the process describing the failure of a minimal cut set is a 'delayed semi-regenerative process'. (Auth.)

  11. Crane Safety Assessment Method Based on Entropy and Cumulative Prospect Theory

    Directory of Open Access Journals (Sweden)

    Aihua Li

    2017-01-01

    Full Text Available Assessing the safety status of cranes is an important problem. To overcome the inaccuracies and misjudgments in such assessments, this work describes a safety assessment method for cranes that combines entropy and cumulative prospect theory. Firstly, the proposed method transforms the set of evaluation indices into an evaluation vector. Secondly, a decision matrix is then constructed from the evaluation vectors and evaluation standards, and an entropy-based technique is applied to calculate the index weights. Thirdly, positive and negative prospect value matrices are established from reference points based on the positive and negative ideal solutions. Thus, this enables the crane safety grade to be determined according to the ranked comprehensive prospect values. Finally, the safety status of four general overhead traveling crane samples is evaluated to verify the rationality and feasibility of the proposed method. The results demonstrate that the method described in this paper can precisely and reasonably reflect the safety status of a crane.

  12. Learning curve for robotic-assisted surgery for rectal cancer: use of the cumulative sum method.

    Science.gov (United States)

    Yamaguchi, Tomohiro; Kinugasa, Yusuke; Shiomi, Akio; Sato, Sumito; Yamakawa, Yushi; Kagawa, Hiroyasu; Tomioka, Hiroyuki; Mori, Keita

    2015-07-01

    Few data are available to assess the learning curve for robotic-assisted surgery for rectal cancer. The aim of the present study was to evaluate the learning curve for robotic-assisted surgery for rectal cancer by a surgeon at a single institute. From December 2011 to August 2013, a total of 80 consecutive patients who underwent robotic-assisted surgery for rectal cancer performed by the same surgeon were included in this study. The learning curve was analyzed using the cumulative sum method. This method was used for all 80 cases, taking into account operative time. Operative procedures included anterior resections in 6 patients, low anterior resections in 46 patients, intersphincteric resections in 22 patients, and abdominoperineal resections in 6 patients. Lateral lymph node dissection was performed in 28 patients. Median operative time was 280 min (range 135-683 min), and median blood loss was 17 mL (range 0-690 mL). No postoperative complications of Clavien-Dindo classification Grade III or IV were encountered. We arranged operative times and calculated cumulative sum values, allowing differentiation of three phases: phase I, Cases 1-25; phase II, Cases 26-50; and phase III, Cases 51-80. Our data suggested three phases of the learning curve in robotic-assisted surgery for rectal cancer. The first 25 cases formed the learning phase.

  13. Probability and Cumulative Density Function Methods for the Stochastic Advection-Reaction Equation

    Energy Technology Data Exchange (ETDEWEB)

    Barajas-Solano, David A.; Tartakovsky, Alexandre M.

    2018-01-01

    We present a cumulative density function (CDF) method for the probabilistic analysis of $d$-dimensional advection-dominated reactive transport in heterogeneous media. We employ a probabilistic approach in which epistemic uncertainty on the spatial heterogeneity of Darcy-scale transport coefficients is modeled in terms of random fields with given correlation structures. Our proposed CDF method employs a modified Large-Eddy-Diffusivity (LED) approach to close and localize the nonlocal equations governing the one-point PDF and CDF of the concentration field, resulting in a $(d + 1)$ dimensional PDE. Compared to the classsical LED localization, the proposed modified LED localization explicitly accounts for the mean-field advective dynamics over the phase space of the PDF and CDF. To illustrate the accuracy of the proposed closure, we apply our CDF method to one-dimensional single-species reactive transport with uncertain, heterogeneous advection velocities and reaction rates modeled as random fields.

  14. Cumulant-Based Coherent Signal Subspace Method for Bearing and Range Estimation

    Directory of Open Access Journals (Sweden)

    Bourennane Salah

    2007-01-01

    Full Text Available A new method for simultaneous range and bearing estimation for buried objects in the presence of an unknown Gaussian noise is proposed. This method uses the MUSIC algorithm with noise subspace estimated by using the slice fourth-order cumulant matrix of the received data. The higher-order statistics aim at the removal of the additive unknown Gaussian noise. The bilinear focusing operator is used to decorrelate the received signals and to estimate the coherent signal subspace. A new source steering vector is proposed including the acoustic scattering model at each sensor. Range and bearing of the objects at each sensor are expressed as a function of those at the first sensor. This leads to the improvement of object localization anywhere, in the near-field or in the far-field zone of the sensor array. Finally, the performances of the proposed method are validated on data recorded during experiments in a water tank.

  15. Method for calculating individual equivalent doses and cumulative dose of population in the vicinity of nuclear power plant site

    International Nuclear Information System (INIS)

    Namestek, L.; Khorvat, D; Shvets, J.; Kunz, Eh.

    1976-01-01

    A method of calculating the doses of external and internal person irradiation in the nuclear power plant vicinity under conditions of normal operation and accident situations has been described. The main difference between the above method and methods used up to now is the use of a new antropomorphous representation of a human body model together with all the organs. The antropomorphous model of human body and its organs is determined as a set of simple solids, coordinates of disposistion of the solids, sizes, masses, densities and composition corresponding the genuine organs. The use of the Monte-Carlo method is the second difference. The results of the calculations according to the model suggested can be used for determination: a critical group of inhabitans under conditions of normal plant operation; groups of inhabitants most subjected to irradiation in the case of possible accident; a critical sector with a maximum collective dose in the case of an accident; a critical radioisotope favouring the greatest contribution to an individual equivalent dose; critical irradiation ways promoting a maximum contribution to individual equivalent doses; cumulative collective doses for the whole region or for a chosen part of the region permitting to estimate a population dose. The consequent method evoluation suggests the development of separate units of the calculationg program, critical application and the selection of input data of physical, plysiological and ecological character and improvement of the calculated program for the separate concrete events [ru

  16. Action Research Methods: Plain and Simple

    Science.gov (United States)

    Klein, Sheri R., Ed.

    2012-01-01

    Among the plethora of action research books on the market, there is no one text exclusively devoted to understanding how to acquire and interpret research data. Action Research Methods provides a balanced overview of the quantitative and qualitative methodologies and methods for conducting action research within a variety of educational…

  17. A simple method for human peripheral blood monocyte Isolation

    Directory of Open Access Journals (Sweden)

    Marcos C de Almeida

    2000-04-01

    Full Text Available We describe a simple method using percoll gradient for isolation of highly enriched human monocytes. High numbers of fully functional cells are obtained from whole blood or buffy coat cells. The use of simple laboratory equipment and a relatively cheap reagent makes the described method a convenient approach to obtaining human monocytes.

  18. A simple and rapid method to estimate radiocesium in man

    International Nuclear Information System (INIS)

    Kindl, P.; Steger, F.

    1990-09-01

    A simple and rapid method for monitoring internal contamination of radiocesium in man was developed. This method is based on measurements of the γ-rays emitted from the muscular parts between the thights by a simple NaJ(Tl)-system. The experimental procedure, the calibration, the estimation of the body activity and results are explained and discussed. (Authors)

  19. A wavelet filtering method for cumulative gamma spectroscopy used in wear measurements

    International Nuclear Information System (INIS)

    Bianchi, Davide; Lenauer, Claudia; Betz, Gerhard; Vernes, András

    2017-01-01

    Continuous ultra-mild wear quantification using radioactive isotopes involves measuring very low amounts of activity in limited time intervals. This results in gamma spectra with poor signal-to-noise ratio and hence very scattered wear data, especially during running-in, where wear is intrinsically low. Therefore, advanced filtering methods reducing the wear data scattering and making the calculation of the main peak area more accurate are mandatory. An energy-time dependent threshold for wavelet detail coefficients based on Poisson statistics and using a combined Barwell law for the estimation of the average photon counting rate is then introduced. In this manner, it was shown that the accuracy of running-in wear quantification is enhanced. - Highlights: • Time-dependent Poisson statistics. • Wavelet-based filtering of cumulative gamma spectra. • Improvement of low wear analysis.

  20. Simulation by the method of inverse cumulative distribution function applied in optimising of foundry plant production

    Directory of Open Access Journals (Sweden)

    J. Szymszal

    2009-01-01

    Full Text Available The study discusses application of computer simulation based on the method of inverse cumulative distribution function. The simulationrefers to an elementary static case, which can also be solved by physical experiment, consisting mainly in observations of foundryproduction in a selected foundry plant. For the simulation and forecasting of foundry production quality in selected cast iron grade, arandom number generator of Excel calculation sheet was chosen. Very wide potentials of this type of simulation when applied to theevaluation of foundry production quality were demonstrated, using a number generator of even distribution for generation of a variable ofan arbitrary distribution, especially of a preset empirical distribution, without any need of adjusting to this variable the smooth theoreticaldistributions.

  1. A simple method to estimate interwell autocorrelation

    Energy Technology Data Exchange (ETDEWEB)

    Pizarro, J.O.S.; Lake, L.W. [Univ. of Texas, Austin, TX (United States)

    1997-08-01

    The estimation of autocorrelation in the lateral or interwell direction is important when performing reservoir characterization studies using stochastic modeling. This paper presents a new method to estimate the interwell autocorrelation based on parameters, such as the vertical range and the variance, that can be estimated with commonly available data. We used synthetic fields that were generated from stochastic simulations to provide data to construct the estimation charts. These charts relate the ratio of areal to vertical variance and the autocorrelation range (expressed variously) in two directions. Three different semivariogram models were considered: spherical, exponential and truncated fractal. The overall procedure is demonstrated using field data. We find that the approach gives the most self-consistent results when it is applied to previously identified facies. Moreover, the autocorrelation trends follow the depositional pattern of the reservoir, which gives confidence in the validity of the approach.

  2. Simple, miniaturized blood plasma extraction method.

    Science.gov (United States)

    Kim, Jin-Hee; Woenker, Timothy; Adamec, Jiri; Regnier, Fred E

    2013-12-03

    A rapid plasma extraction technology that collects a 2.5 μL aliquot of plasma within three minutes from a finger-stick derived drop of blood was evaluated. The utility of the plasma extraction cards used was that a paper collection disc bearing plasma was produced that could be air-dried in fifteen minutes and placed in a mailing envelop for transport to an analytical laboratory. This circumvents the need for venipuncture and blood collection in specialized vials by a phlebotomist along with centrifugation and refrigerated storage. Plasma extraction was achieved by applying a blood drop to a membrane stack through which plasma was drawn by capillary action. During the course of plasma migration to a collection disc at the bottom of the membrane stack blood cells were removed by a combination of adsorption and filtration. After the collection disc filled with an aliquot of plasma the upper membranes were stripped from the collection card and the collection disc was air-dried. Intercard differences in the volume of plasma collected varied approximately 1% while volume variations of less than 2% were seen with hematocrit levels ranging from 20% to 71%. Dried samples bearing metabolites and proteins were then extracted from the disc and analyzed. 25-Hydroxy vitamin D was quantified by LC-MS/MS analysis following derivatization with a secosteroid signal enhancing tag that imparted a permanent positive charge to the vitamin and reduced the limit of quantification (LOQ) to 1 pg of collected vitamin on the disc; comparable to values observed with liquid-liquid extraction (LLE) of a venipuncture sample. A similar study using conventional proteomics methods and spectral counting for quantification was conducted with yeast enolase added to serum as an internal standard. The LOQ with extracted serum samples for enolase was 1 μM, linear from 1 to 40 μM, the highest concentration examined. In all respects protein quantification with extracted serum samples was comparable to

  3. TREND: a program using cumulative sum methods to detect long-term trends in data

    International Nuclear Information System (INIS)

    Cranston, R.J.; Dunbar, R.M.; Jarvis, R.G.

    1976-01-01

    TREND is a computer program, in FORTRAN, to investigate data for long-term trends that are masked by short-term statistical fluctuations. To do this, it calculates and plots the cumulative sum of deviations from a chosen mean. As a further aid to diagnosis, the procedure can be repeated with a summation of the cumulative sum itself. (author)

  4. Solution of the schrodinger equation in one dimension by simple method for a simple step potential

    International Nuclear Information System (INIS)

    Ertik, H.

    2005-01-01

    The coefficients of the transmission and reflection for the simple-step barrier potential were calculated by a simple method. Their values were entirely different from those often encountered in the literature. Especially in the case that the total energy is equal to the barrier potential, the value of 0,20 for the reflection coefficient was obtained whereas this is zero in the literature. This may be considered as an interesting point

  5. Probabilistic performance estimators for computational chemistry methods: The empirical cumulative distribution function of absolute errors

    Science.gov (United States)

    Pernot, Pascal; Savin, Andreas

    2018-06-01

    Benchmarking studies in computational chemistry use reference datasets to assess the accuracy of a method through error statistics. The commonly used error statistics, such as the mean signed and mean unsigned errors, do not inform end-users on the expected amplitude of prediction errors attached to these methods. We show that, the distributions of model errors being neither normal nor zero-centered, these error statistics cannot be used to infer prediction error probabilities. To overcome this limitation, we advocate for the use of more informative statistics, based on the empirical cumulative distribution function of unsigned errors, namely, (1) the probability for a new calculation to have an absolute error below a chosen threshold and (2) the maximal amplitude of errors one can expect with a chosen high confidence level. Those statistics are also shown to be well suited for benchmarking and ranking studies. Moreover, the standard error on all benchmarking statistics depends on the size of the reference dataset. Systematic publication of these standard errors would be very helpful to assess the statistical reliability of benchmarking conclusions.

  6. On the method of logarithmic cumulants for parametric probability density function estimation.

    Science.gov (United States)

    Krylov, Vladimir A; Moser, Gabriele; Serpico, Sebastiano B; Zerubia, Josiane

    2013-10-01

    Parameter estimation of probability density functions is one of the major steps in the area of statistical image and signal processing. In this paper we explore several properties and limitations of the recently proposed method of logarithmic cumulants (MoLC) parameter estimation approach which is an alternative to the classical maximum likelihood (ML) and method of moments (MoM) approaches. We derive the general sufficient condition for a strong consistency of the MoLC estimates which represents an important asymptotic property of any statistical estimator. This result enables the demonstration of the strong consistency of MoLC estimates for a selection of widely used distribution families originating from (but not restricted to) synthetic aperture radar image processing. We then derive the analytical conditions of applicability of MoLC to samples for the distribution families in our selection. Finally, we conduct various synthetic and real data experiments to assess the comparative properties, applicability and small sample performance of MoLC notably for the generalized gamma and K families of distributions. Supervised image classification experiments are considered for medical ultrasound and remote-sensing SAR imagery. The obtained results suggest that MoLC is a feasible and computationally fast yet not universally applicable alternative to MoM. MoLC becomes especially useful when the direct ML approach turns out to be unfeasible.

  7. A simple and efficient electrochemical reductive method for ...

    Indian Academy of Sciences (India)

    Administrator

    This approach opens up a new, practical and green reducing method to prepare large- scale graphene. ... has the following significant advantages: (1) It is simple to operate. .... The authors thank the National High Technology Research.

  8. A simple flow-concentration modelling method for integrating water ...

    African Journals Online (AJOL)

    A simple flow-concentration modelling method for integrating water quality and ... flow requirements are assessed for maintenance low flow, drought low flow ... the instream concentrations of chemical constituents that will arise from different ...

  9. Simple-MSSM: a simple and efficient method for simultaneous multi-site saturation mutagenesis.

    Science.gov (United States)

    Cheng, Feng; Xu, Jian-Miao; Xiang, Chao; Liu, Zhi-Qiang; Zhao, Li-Qing; Zheng, Yu-Guo

    2017-04-01

    To develop a practically simple and robust multi-site saturation mutagenesis (MSSM) method that enables simultaneously recombination of amino acid positions for focused mutant library generation. A general restriction enzyme-free and ligase-free MSSM method (Simple-MSSM) based on prolonged overlap extension PCR (POE-PCR) and Simple Cloning techniques. As a proof of principle of Simple-MSSM, the gene of eGFP (enhanced green fluorescent protein) was used as a template gene for simultaneous mutagenesis of five codons. Forty-eight randomly selected clones were sequenced. Sequencing revealed that all the 48 clones showed at least one mutant codon (mutation efficiency = 100%), and 46 out of the 48 clones had mutations at all the five codons. The obtained diversities at these five codons are 27, 24, 26, 26 and 22, respectively, which correspond to 84, 75, 81, 81, 69% of the theoretical diversity offered by NNK-degeneration (32 codons; NNK, K = T or G). The enzyme-free Simple-MSSM method can simultaneously and efficiently saturate five codons within one day, and therefore avoid missing interactions between residues in interacting amino acid networks.

  10. A simple finite element method for linear hyperbolic problems

    International Nuclear Information System (INIS)

    Mu, Lin; Ye, Xiu

    2017-01-01

    Here, we introduce a simple finite element method for solving first order hyperbolic equations with easy implementation and analysis. Our new method, with a symmetric, positive definite system, is designed to use discontinuous approximations on finite element partitions consisting of arbitrary shape of polygons/polyhedra. Error estimate is established. Extensive numerical examples are tested that demonstrate the robustness and flexibility of the method.

  11. A simple approximation method for dilute Ising systems

    International Nuclear Information System (INIS)

    Saber, M.

    1996-10-01

    We describe a simple approximate method to analyze dilute Ising systems. The method takes into consideration the fluctuations of the effective field, and is based on a probability distribution of random variables which correctly accounts for all the single site kinematic relations. It is shown that the simplest approximation gives satisfactory results when compared with other methods. (author). 12 refs, 2 tabs

  12. Simple and inexpensive method for CT-guided stereotaxy

    Energy Technology Data Exchange (ETDEWEB)

    Wester, K; Sortland, O; Hauglie-Hanssen, E

    1981-01-01

    A simple and inexpensive method for CT-guided stereotaxy is described. The method requires neither sophisticated computer programs nor additional stereotactic equipment, such as special head holders for the CT, and can be easily obtained without technical assistance. The method is designed to yield the vertical coordinates.

  13. A simple method for generating exactly solvable quantum mechanical potentials

    CERN Document Server

    Williams, B W

    1993-01-01

    A simple transformation method permitting the generation of exactly solvable quantum mechanical potentials from special functions solving second-order differential equations is reviewed. This method is applied to Gegenbauer polynomials to generate an attractive radial potential. The relationship of this method to the determination of supersymmetric quantum mechanical superpotentials is discussed, and the superpotential for the radial potential is also derived. (author)

  14. Incorporating cumulative effects into environmental assessments of mariculture: Limitations and failures of current siting methods

    International Nuclear Information System (INIS)

    King, Sarah C.; Pushchak, Ronald

    2008-01-01

    Assessing and evaluating the cumulative impacts of multiple marine aquaculture facilities has proved difficult in environmental assessment. A retrospective review of 23 existing mariculture farms in southwestern New Brunswick was conducted to determine whether cumulative interactions would have justified site approvals. Based on current scientific evidence of cumulative effects, six new criteria were added to a set of far-field impacts and other existing criteria were expanded to include regional and cumulative environmental impacts in Hargrave's [Hargrave BT. A traffic light decision system for marine finfish aquaculture siting. Ocean Coast Manag 2002; 45:215-35.] Traffic Light Decision Support System (DSS) presently used in Canadian aquaculture environmental assessments. Before mitigation, 19 of the 23 sites failed the amended set of criteria and after considering mitigation, 8 sites failed. Site and ecosystem indices yielded varying site acceptability scores; however, many sites would not have been approved if siting decisions had been made within a regional management framework and cumulative impact criteria were considered in the site evaluation process

  15. Cumulative radiation effect

    International Nuclear Information System (INIS)

    Kirk, J.; Gray, W.M.; Watson, E.R.

    1977-01-01

    In five previous papers, the concept of Cumulative Radiation Effect (CRE) has been presented as a scale of accumulative sub-tolerance radiation damage, with a unique value of the CRE describing a specific level of radiation effect. Simple nomographic and tabular methods for the solution of practical problems in radiotherapy are now described. An essential feature of solving a CRE problem is firstly to present it in a concise and readily appreciated form, and, to do this, nomenclature has been introduced to describe schedules and regimes as compactly as possible. Simple algebraic equations have been derived to describe the CRE achieved by multi-schedule regimes. In these equations, the equivalence conditions existing at the junctions between schedules are not explicit and the equations are based on the CREs of the constituent schedules assessed individually without reference to their context in the regime as a whole. This independent evaluation of CREs for each schedule has resulted in a considerable simplification in the calculation of complex problems. The calculations are further simplified by the use of suitable tables and nomograms, so that the mathematics involved is reduced to simple arithmetical operations which require at the most the use of a slide rule but can be done by hand. The order of procedure in the presentation and calculation of CRE problems can be summarised in an evaluation procedure sheet. The resulting simple methods for solving practical problems of any complexity on the CRE-system are demonstrated by a number of examples. (author)

  16. A Simple HPLC Bioanalytical Method for the Determination of ...

    African Journals Online (AJOL)

    Purpose: To develop a simple, accurate, and precise high performance chromatography (HPLC) method with spectrophotometric detection for the determination of doxorubicin hydrochloride in rat plasma. Methods: Doxorubicin hydrochloride and daunorubicin hydrochloride (internal standard, IS) were separated on a C18 ...

  17. Gallium determination with Rodamina B: a simple method

    International Nuclear Information System (INIS)

    Queiroz, R.R.U. de.

    1981-01-01

    A simple method for determining gallium with Rhodamine B, by the modification of the method proposed by Onishi and Sandell. The complex (RH) GaCl 4 is extracted with a mixture benzene-ethylacetate (3:1 V/V), from an aqueous medium 6 M in hydrochloric acid. The interference of foreign ions is studied. (C.G.C.) [pt

  18. Cumulative Advantage in the Skill Development of STEM Graduate Students: A Mixed-Methods Study

    Science.gov (United States)

    Feldon, David F.; Maher, Michelle A.; Roksa, Josipa; Peugh, James

    2016-01-01

    Studies of skill development often describe a process of cumulative advantage, in which small differences in initial skill compound over time, leading to increasing skill gaps between those with an initial advantage and those without. We offer evidence of a similar phenomenon accounting for differential patterns of research skill development in…

  19. Micro- and macroanalytical methods for the determination of the specific cumulated energy consumption for the production of consumer goods

    Energy Technology Data Exchange (ETDEWEB)

    Flaschar, W.

    1979-01-01

    As an estimation shows the total share of the final energy consumption for the production of goods amounts to more than 50%. Consequently, the present study is directed toward an important field. Apart from systemizing and confronting methods which have already been used it also tries to largely genereralize the problems of the specific cumulated energy consumption (SCEC). First, the terminolgy of energy and materials balances is fundamentally defined and determined. The influencing factors of the SCEC are analyzed and presented and the essential variables of energy consumption are explained with the help of examples. The fundamentals of cumulation as well as micro- and macroanalytical methods for the determination of the SCEC are worked out and discussed. The last part of the study shows the application of general methods and the solution of special problems when determining the SCEC for a particular product as exemplified by the practice of producing natural yogurt.

  20. The modified simple equation method for solving some fractional ...

    Indian Academy of Sciences (India)

    ... and processes in various areas of natural science. Thus, many effective and powerful methods have been established and improved. In this study, we establish exact solutions of the time fractional biological population model equation and nonlinearfractional Klein–Gordon equation by using the modified simple equation ...

  1. Using container weights to determine irrigation needs: A simple method

    Science.gov (United States)

    R. Kasten Dumroese; Mark E. Montville; Jeremiah R. Pinto

    2015-01-01

    Proper irrigation can reduce water use, water waste, and incidence of disease. Knowing when to irrigate plants in container nurseries can be determined by weighing containers. This simple method is quantifiable, which is a benefit when more than one worker is responsible for irrigation. Irrigation is necessary when the container weighs some target as a proportion of...

  2. Simple Calculation Programs for Biology Methods in Molecular ...

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Simple Calculation Programs for Biology Methods in Molecular Biology. GMAP: A program for mapping potential restriction sites. RE sites in ambiguous and non-ambiguous DNA sequence; Minimum number of silent mutations required for introducing a RE sites; Set ...

  3. A simple method for estimating thermal response of building ...

    African Journals Online (AJOL)

    This paper develops a simple method for estimating the thermal response of building materials in the tropical climatic zone using the basic heat equation. The efficacy of the developed model has been tested with data from three West African cities, namely Kano (lat. 12.1 ºN) Nigeria, Ibadan (lat. 7.4 ºN) Nigeria and Cotonou ...

  4. A simple method of dosimetry for E-beam radiation

    International Nuclear Information System (INIS)

    Spencer, D.S.; Thalacker, V.P.; Chasman, J.N.; Siegel, S.

    1985-01-01

    A simple method utilizing a photochromic 'intensity label' for monitoring electron-beam sources was evaluated. The labels exhibit a color change upon exposure to UV or e-beam radiation. A correlation was found between absorbed energy and Gardner Color Index at low electron-beam doses. (author)

  5. Simple and convenient method for culturing anaerobic bacteria.

    OpenAIRE

    Behbehani, M J; Jordan, H V; Santoro, D L

    1982-01-01

    A simple and convenient method for culturing anaerobic bacteria is described. Cultures can be grown in commercially available flasks normally used for preparation of sterile external solutions. A special disposable rubber flask closure maintains anaerobic conditions in the flask after autoclaving. Growth of a variety of anaerobic oral bacteria was comparable to that obtained after anaerobic incubation of broth cultures in Brewer Anaerobic Jars.

  6. A simple three dimensional wide-angle beam propagation method

    Science.gov (United States)

    Ma, Changbao; van Keuren, Edward

    2006-05-01

    The development of three dimensional (3-D) waveguide structures for chip scale planar lightwave circuits (PLCs) is hampered by the lack of effective 3-D wide-angle (WA) beam propagation methods (BPMs). We present a simple 3-D wide-angle beam propagation method (WA-BPM) using Hoekstra’s scheme along with a new 3-D wave equation splitting method. The applicability, accuracy and effectiveness of our method are demonstrated by applying it to simulations of wide-angle beam propagation and comparing them with analytical solutions.

  7. A simple method for multiday imaging of slice cultures.

    Science.gov (United States)

    Seidl, Armin H; Rubel, Edwin W

    2010-01-01

    The organotypic slice culture (Stoppini et al. A simple method for organotypic cultures of nervous tissue. 1991;37:173-182) has become the method of choice to answer a variety of questions in neuroscience. For many experiments, however, it would be beneficial to image or manipulate a slice culture repeatedly, for example, over the course of many days. We prepared organotypic slice cultures of the auditory brainstem of P3 and P4 mice and kept them in vitro for up to 4 weeks. Single cells in the auditory brainstem were transfected with plasmids expressing fluorescent proteins by way of electroporation (Haas et al. Single-cell electroporation for gene transfer in vivo. 2001;29:583-591). The culture was then placed in a chamber perfused with oxygenated ACSF and the labeled cell imaged with an inverted wide-field microscope repeatedly for multiple days, recording several time-points per day, before returning the slice to the incubator. We describe a simple method to image a slice culture preparation during the course of multiple days and over many continuous hours, without noticeable damage to the tissue or photobleaching. Our method uses a simple, inexpensive custom-built insulator constructed around the microscope to maintain controlled temperature and uses a perfusion chamber as used for in vitro slice recordings. (c) 2009 Wiley-Liss, Inc.

  8. A simple method for DNA isolation from Xanthomonas spp.

    Directory of Open Access Journals (Sweden)

    Gomes Luiz Humberto

    2000-01-01

    Full Text Available A simple DNA isolation method was developed with routine chemicals that yields high quality and integrity preparations when compared to some of the most well known protocols. The method described does not require the use of lysing enzymes, water bath and the DNA was obtained within 40 minutes The amount of nucleic acid extracted (measured in terms of absorbancy at 260 nm from strains of Xanthomonas spp., Pseudomonas spp. and Erwinia spp. was two to five times higher than that of the most commonly used method.

  9. A simple statistical method for catch comparison studies

    DEFF Research Database (Denmark)

    Holst, René; Revill, Andrew

    2009-01-01

    For analysing catch comparison data, we propose a simple method based on Generalised Linear Mixed Models (GLMM) and use polynomial approximations to fit the proportions caught in the test codend. The method provides comparisons of fish catch at length by the two gears through a continuous curve...... with a realistic confidence band. We demonstrate the versatility of this method, on field data obtained from the first known testing in European waters of the Rhode Island (USA) 'Eliminator' trawl. These data are interesting as they include a range of species with different selective patterns. Crown Copyright (C...

  10. Simple statistical methods for software engineering data and patterns

    CERN Document Server

    Pandian, C Ravindranath

    2015-01-01

    Although there are countless books on statistics, few are dedicated to the application of statistical methods to software engineering. Simple Statistical Methods for Software Engineering: Data and Patterns fills that void. Instead of delving into overly complex statistics, the book details simpler solutions that are just as effective and connect with the intuition of problem solvers.Sharing valuable insights into software engineering problems and solutions, the book not only explains the required statistical methods, but also provides many examples, review questions, and case studies that prov

  11. Simple method for quick estimation of aquifer hydrogeological parameters

    Science.gov (United States)

    Ma, C.; Li, Y. Y.

    2017-08-01

    Development of simple and accurate methods to determine the aquifer hydrogeological parameters was of importance for groundwater resources assessment and management. Aiming at the present issue of estimating aquifer parameters based on some data of the unsteady pumping test, a fitting function of Theis well function was proposed using fitting optimization method and then a unitary linear regression equation was established. The aquifer parameters could be obtained by solving coefficients of the regression equation. The application of the proposed method was illustrated, using two published data sets. By the error statistics and analysis on the pumping drawdown, it showed that the method proposed in this paper yielded quick and accurate estimates of the aquifer parameters. The proposed method could reliably identify the aquifer parameters from long distance observed drawdowns and early drawdowns. It was hoped that the proposed method in this paper would be helpful for practicing hydrogeologists and hydrologists.

  12. A simple method for affinity purification of radiolabeled monoclonal antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Juweid, M; Sato, J; Paik, C; Onay-Basaran, S; Weinstein, J N; Neumann, R D [National Cancer Inst., Bethesda, MD (United States)

    1993-04-01

    A simple method is described for affinity purification of radiolabeled antibodies using glutaraldehyde-fixed tumor target cells. The cell-bound antibody fraction is removed from the cells by an acid wash and then immediately subjected to buffer-exchange chromatography. The method was applied to the D3 murine monoclonal antibody which binds to a 290 kDa antigen on the surface of Line 10 guinea pig carcinoma cells. No alteration in the molecular size profile was detected after acid washing. Purification resulted in a significant increase in immunoreactivity by an average of 14 [+-] 47% (SD; range 4-30%). (author).

  13. Process control and optimization with simple interval calculation method

    DEFF Research Database (Denmark)

    Pomerantsev, A.; Rodionova, O.; Høskuldsson, Agnar

    2006-01-01

    for the quality improvement in the course of production. The latter is an active quality optimization, which takes into account the actual history of the process. The advocate approach is allied to the conventional method of multivariate statistical process control (MSPC) as it also employs the historical process......Methods of process control and optimization are presented and illustrated with a real world example. The optimization methods are based on the PLS block modeling as well as on the simple interval calculation methods of interval prediction and object status classification. It is proposed to employ...... the series of expanding PLS/SIC models in order to support the on-line process improvements. This method helps to predict the effect of planned actions on the product quality and thus enables passive quality control. We have also considered an optimization approach that proposes the correcting actions...

  14. Playing It Safe: Assessing Cumulative Impact and Social Vulnerability through an Environmental Justice Screening Method in the South Coast Air Basin, California

    Directory of Open Access Journals (Sweden)

    Justin Scoggins

    2011-05-01

    Full Text Available Regulatory agencies, including the U.S. Environmental Protection Agency (US EPA and state authorities like the California Air Resources Board (CARB, have sought to address the concerns of environmental justice (EJ advocates who argue that chemical-by-chemical and source-specific assessments of potential health risks of environmental hazards do not reflect the multiple environmental and social stressors faced by vulnerable communities. We propose an Environmental Justice Screening Method (EJSM as a relatively simple, flexible and transparent way to examine the relative rank of cumulative impacts and social vulnerability within metropolitan regions and determine environmental justice areas based on more than simply the demographics of income and race. We specifically organize 23 indicator metrics into three categories: (1 hazard proximity and land use; (2 air pollution exposure and estimated health risk; and (3 social and health vulnerability. For hazard proximity, the EJSM uses GIS analysis to create a base map by intersecting land use data with census block polygons, and calculates hazard proximity measures based on locations within various buffer distances. These proximity metrics are then summarized to the census tract level where they are combined with tract centroid-based estimates of pollution exposure and health risk and socio-economic status (SES measures. The result is a cumulative impacts (CI score for ranking neighborhoods within regions that can inform diverse stakeholders seeking to identify local areas that might need targeted regulatory strategies to address environmental justice concerns.

  15. A Simple and Automatic Method for Locating Surgical Guide Hole

    Science.gov (United States)

    Li, Xun; Chen, Ming; Tang, Kai

    2017-12-01

    Restoration-driven surgical guides are widely used in implant surgery. This study aims to provide a simple and valid method of automatically locating surgical guide hole, which can reduce operator's experiences and improve the design efficiency and quality of surgical guide. Few literatures can be found on this topic and the paper proposed a novel and simple method to solve this problem. In this paper, a local coordinate system for each objective tooth is geometrically constructed in CAD system. This coordinate system well represents dental anatomical features and the center axis of the objective tooth (coincide with the corresponding guide hole axis) can be quickly evaluated in this coordinate system, finishing the location of the guide hole. The proposed method has been verified by comparing two types of benchmarks: manual operation by one skilled doctor with over 15-year experiences (used in most hospitals) and automatic way using one popular commercial package Simplant (used in few hospitals).Both the benchmarks and the proposed method are analyzed in their stress distribution when chewing and biting. The stress distribution is visually shown and plotted as a graph. The results show that the proposed method has much better stress distribution than the manual operation and slightly better than Simplant, which will significantly reduce the risk of cervical margin collapse and extend the wear life of the restoration.

  16. A simple transformation independent method for outlier definition.

    Science.gov (United States)

    Johansen, Martin Berg; Christensen, Peter Astrup

    2018-04-10

    Definition and elimination of outliers is a key element for medical laboratories establishing or verifying reference intervals (RIs). Especially as inclusion of just a few outlying observations may seriously affect the determination of the reference limits. Many methods have been developed for definition of outliers. Several of these methods are developed for the normal distribution and often data require transformation before outlier elimination. We have developed a non-parametric transformation independent outlier definition. The new method relies on drawing reproducible histograms. This is done by using defined bin sizes above and below the median. The method is compared to the method recommended by CLSI/IFCC, which uses Box-Cox transformation (BCT) and Tukey's fences for outlier definition. The comparison is done on eight simulated distributions and an indirect clinical datasets. The comparison on simulated distributions shows that without outliers added the recommended method in general defines fewer outliers. However, when outliers are added on one side the proposed method often produces better results. With outliers on both sides the methods are equally good. Furthermore, it is found that the presence of outliers affects the BCT, and subsequently affects the determined limits of current recommended methods. This is especially seen in skewed distributions. The proposed outlier definition reproduced current RI limits on clinical data containing outliers. We find our simple transformation independent outlier detection method as good as or better than the currently recommended methods.

  17. Simple method to generate and fabricate stochastic porous scaffolds

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Nan, E-mail: y79nzw@163.com; Gao, Lilan; Zhou, Kuntao

    2015-11-01

    Considerable effort has been made to generate regular porous structures (RPSs) using function-based methods, although little effort has been made for constructing stochastic porous structures (SPSs) using the same methods. In this short communication, we propose a straightforward method for SPS construction that is simple in terms of methodology and the operations used. Using our method, we can obtain a SPS with functionally graded, heterogeneous and interconnected pores, target pore size and porosity distributions, which are useful for applications in tissue engineering. The resulting SPS models can be directly fabricated using additive manufacturing (AM) techniques. - Highlights: • Random porous structures are constructed based on their regular counterparts. • Functionally graded random pores can be constructed easily. • The scaffolds can be directly fabricated using additive manufacturing techniques.

  18. Simple Screening Methods for Drought and Heat Tolerance in Cowpea

    International Nuclear Information System (INIS)

    Singh, B. B.

    2000-10-01

    Success in breeding for drought tolerance has not been as pronounced as for other traits. This is partly due to lack of simple, cheap and reliable screening methods to select drought tolerant plants/progenies from the segregating populations and partly due to complexity of factors involved in drought tolerance. Measuring drought tolerance through physiological parameters is expensive, time consuming and difficult to use for screening large numbers of lines and segregating populations. Since several factors/mechanisms (in shoot and root) operate independently and/or jointly to enable plants to cope with drought stress, drought tolerance appears as a complex trait. However, if these factors/mechanisms can be separated and studied individually, the components leading to drought tolerance will appear less complex and may be easy to manipulate by breeders. We have developed a simple box screening method for shoot drought tolerance in cowpea, which eliminates the effects of roots and permits non-destructive visual identification of shoot dehydration tolerance. We have also developed a 'root-box pin-board' method to study two dimensional root architecture of individual plants. Using these methods, we have identified two mechanisms of shoot drought tolerance in cowpea which are controlled by single dominant genes and major difference for root architecture among cowpea varieties. Combining deep and dense root system with shoot dehydration tolerance results into highly drought tolerant plants

  19. A simple method for estimating the entropy of neural activity

    International Nuclear Information System (INIS)

    Berry II, Michael J; Tkačik, Gašper; Dubuis, Julien; Marre, Olivier; Da Silveira, Rava Azeredo

    2013-01-01

    The number of possible activity patterns in a population of neurons grows exponentially with the size of the population. Typical experiments explore only a tiny fraction of the large space of possible activity patterns in the case of populations with more than 10 or 20 neurons. It is thus impossible, in this undersampled regime, to estimate the probabilities with which most of the activity patterns occur. As a result, the corresponding entropy—which is a measure of the computational power of the neural population—cannot be estimated directly. We propose a simple scheme for estimating the entropy in the undersampled regime, which bounds its value from both below and above. The lower bound is the usual ‘naive’ entropy of the experimental frequencies. The upper bound results from a hybrid approximation of the entropy which makes use of the naive estimate, a maximum entropy fit, and a coverage adjustment. We apply our simple scheme to artificial data, in order to check their accuracy; we also compare its performance to those of several previously defined entropy estimators. We then apply it to actual measurements of neural activity in populations with up to 100 cells. Finally, we discuss the similarities and differences between the proposed simple estimation scheme and various earlier methods. (paper)

  20. Simple method for correct enumeration of Staphylococcus aureus

    DEFF Research Database (Denmark)

    Haaber, J.; Cohn, M. T.; Petersen, A.

    2016-01-01

    culture. When grown in such liquid cultures, the human pathogen Staphylococcus aureus is characterized by its aggregation of single cells into clusters of variable size. Here, we show that aggregation during growth in the laboratory standard medium tryptic soy broth (TSB) is common among clinical...... and laboratory S. aureus isolates and that aggregation may introduce significant bias when applying standard enumeration methods on S. aureus growing in laboratory batch cultures. We provide a simple and efficient sonication procedure, which can be applied prior to optical density measurements to give...

  1. A new and simple gravimetric method for determination of uranium

    International Nuclear Information System (INIS)

    Saxena, A.K.

    1994-01-01

    A new and simple gravimetric method for determining uranium has been described. Using a known quantity of uranyl nitrate as the test solution, an alcoholic solution of 2-amino-2-methyl 1:3 propanediol (AMP) was added slowly. A yellow precipitate was obtained which was filtered through ashless filter paper, washed with alcohol, dried and ignited at 800 degC for 4h. It gave a black powder as a product which was shown by X-ray diffraction to be U 3 O 8 . The percentage error was found in the range -0.09 to +0.89. (author). 8 refs., 1 tab

  2. A simple method suitable to study de novo root organogenesis

    Directory of Open Access Journals (Sweden)

    Xiaodong eChen

    2014-05-01

    Full Text Available De novo root organogenesis is the process in which adventitious roots regenerate from detached or wounded plant tissues or organs. In tissue culture, appropriate types and concentrations of plant hormones in the medium are critical for inducing adventitious roots. However, in natural conditions, regeneration from detached organs is likely to rely on endogenous hormones. To investigate the actions of endogenous hormones and the molecular mechanisms guiding de novo root organogenesis, we developed a simple method to imitate natural conditions for adventitious root formation by culturing Arabidopsis thaliana leaf explants on B5 medium without additive hormones. Here we show that the ability of the leaf explants to regenerate roots depends on the age of the leaf and on certain nutrients in the medium. Based on these observations, we provide examples of how this method can be used in different situations, and how it can be optimized. This simple method could be used to investigate the effects of various physiological and molecular changes on the regeneration of adventitious roots. It is also useful for tracing cell lineage during the regeneration process by differential interference contrast observation of -glucuronidase staining, and by live imaging of proteins labeled with fluorescent tags.

  3. Percutaneous Method of Management of Simple Bone Cyst

    Directory of Open Access Journals (Sweden)

    O. P. Lakhwani

    2013-01-01

    Full Text Available Introduction. Simple bone cyst or unicameral bone cysts are benign osteolytic lesions seen in metadiaphysis of long bones in growing children. Various treatment modalities with variable outcomes have been described in the literature. The case report illustrates the surgical technique of minimally invasive method of treatment. Case Study. A 14-year-old boy was diagnosed as active simple bone cyst proximal humerus with pathological fracture. The patient was treated by minimally invasive percutaneous curettage with titanium elastic nail (TENS and allogenic bone grafting mixed with bone marrow under image intensifier guidance. Results. Pathological fracture was healed and allograft filled in the cavity was well taken up. The patient achieved full range of motion with successful outcome. Conclusion. Minimally invasive percutaneous method using elastic intramedullary nail gives benefit of curettage cyst decompression and stabilization of fracture. Allogenic bone graft fills the cavity and healing of lesion by osteointegration. This method may be considered with advantage of minimally invasive technique in treatment of benign cystic lesions of bone, and the level of evidence was therapeutic level V.

  4. Percutaneous Method of Management of Simple Bone Cyst

    Science.gov (United States)

    Lakhwani, O. P.

    2013-01-01

    Introduction. Simple bone cyst or unicameral bone cysts are benign osteolytic lesions seen in metadiaphysis of long bones in growing children. Various treatment modalities with variable outcomes have been described in the literature. The case report illustrates the surgical technique of minimally invasive method of treatment. Case Study. A 14-year-old boy was diagnosed as active simple bone cyst proximal humerus with pathological fracture. The patient was treated by minimally invasive percutaneous curettage with titanium elastic nail (TENS) and allogenic bone grafting mixed with bone marrow under image intensifier guidance. Results. Pathological fracture was healed and allograft filled in the cavity was well taken up. The patient achieved full range of motion with successful outcome. Conclusion. Minimally invasive percutaneous method using elastic intramedullary nail gives benefit of curettage cyst decompression and stabilization of fracture. Allogenic bone graft fills the cavity and healing of lesion by osteointegration. This method may be considered with advantage of minimally invasive technique in treatment of benign cystic lesions of bone, and the level of evidence was therapeutic level V. PMID:23819089

  5. A Simple Combinatorial Codon Mutagenesis Method for Targeted Protein Engineering.

    Science.gov (United States)

    Belsare, Ketaki D; Andorfer, Mary C; Cardenas, Frida S; Chael, Julia R; Park, Hyun June; Lewis, Jared C

    2017-03-17

    Directed evolution is a powerful tool for optimizing enzymes, and mutagenesis methods that improve enzyme library quality can significantly expedite the evolution process. Here, we report a simple method for targeted combinatorial codon mutagenesis (CCM). To demonstrate the utility of this method for protein engineering, CCM libraries were constructed for cytochrome P450 BM3 , pfu prolyl oligopeptidase, and the flavin-dependent halogenase RebH; 10-26 sites were targeted for codon mutagenesis in each of these enzymes, and libraries with a tunable average of 1-7 codon mutations per gene were generated. Each of these libraries provided improved enzymes for their respective transformations, which highlights the generality, simplicity, and tunability of CCM for targeted protein engineering.

  6. A simple method of screening for metabolic bone disease

    International Nuclear Information System (INIS)

    Broughton, R.B.K.; Evans, W.D.

    1982-01-01

    The purpose of this investigation was to find a simple method -to be used as an adjunct to the conventional bone scintigram- that could differentiate between decreased bone metabolism or mass, i.e., osteoporosis -normal bone- and the group of conditions of increased bone metabolism or mass namely, osteomalacia, renal osteodystrophy, hyperparathyroidism and Paget's disease. The Fogelman's method using the bone to soft tissue ratios from region of interest analysis at 4 hours post injection, was adopted. An initial experience in measuring a value for the count rate density in lumbar vertebrae at 1 hr post injection during conventional bone scintigraphy appears to give a clear indication of the overall rate of bone metabolism. The advantage over whole body retention methods is that the scan performed at the end of the metabolic study will reveal localized bone disease that may otherwise not be anticipated

  7. A comparison of alternative methods of calculating complementary cumulative distribution functions of health effects following an atmospheric radioactive release

    International Nuclear Information System (INIS)

    Ponting, A.C.; Nair, S.

    1984-04-01

    A concept extensively used in studying the consequences of accidental atmospheric radioactive releases is that of the Complementary Cumulative Distribution Function, CCDF. Various methods of calculating CCDFs have been developed with particular applications in putting degraded core accidents in perspective and in identifying release sequences leading to high risks. This note compares three methods with specific reference to their accuracy and computational efficiency. For two of the methods (that used in the US Reactor Safety Study code CRAC2 and extended version of that method), the effects of varying the sector width and considering site-specific population distributions have been determined. For the third method it is only necessary to consider the effects of site-specific population distributions. (author)

  8. A simple headspace equilibration method for measuring dissolved methane

    Science.gov (United States)

    Magen, C; Lapham, L.L.; Pohlman, John W.; Marshall, Kristin N.; Bosman, S.; Casso, Michael; Chanton, J.P.

    2014-01-01

    Dissolved methane concentrations in the ocean are close to equilibrium with the atmosphere. Because methane is only sparingly soluble in seawater, measuring it without contamination is challenging for samples collected and processed in the presence of air. Several methods for analyzing dissolved methane are described in the literature, yet none has conducted a thorough assessment of the method yield, contamination issues during collection, transport and storage, and the effect of temperature changes and preservative. Previous extraction methods transfer methane from water to gas by either a "sparge and trap" or a "headspace equilibration" technique. The gas is then analyzed for methane by gas chromatography. Here, we revisit the headspace equilibration technique and describe a simple, inexpensive, and reliable method to measure methane in fresh and seawater, regardless of concentration. Within the range of concentrations typically found in surface seawaters (2-1000 nmol L-1), the yield of the method nears 100% of what is expected from solubility calculation following the addition of known amount of methane. In addition to being sensitive (detection limit of 0.1 ppmv, or 0.74 nmol L-1), this method requires less than 10 min per sample, and does not use highly toxic chemicals. It can be conducted with minimum materials and does not require the use of a gas chromatograph at the collection site. It can therefore be used in various remote working environments and conditions.

  9. Simple method for the estimation of glomerular filtration rate

    Energy Technology Data Exchange (ETDEWEB)

    Groth, T [Group for Biomedical Informatics, Uppsala Univ. Data Center, Uppsala (Sweden); Tengstroem, B [District General Hospital, Skoevde (Sweden)

    1977-02-01

    A simple method is presented for indirect estimation of the glomerular filtration rate from two venous blood samples, drawn after a single injection of a small dose of (/sup 125/I)sodium iothalamate (10 ..mu..Ci). The method does not require exact dosage, as the first sample, taken after a few minutes (t=5 min) after injection, is used to normilize the value of the second sample, which should be taken in between 2 to 4 h after injection. The glomerular filtration rate, as measured by standard insulin clearance, may then be predicted from the logarithm of the normalized value and linear regression formulas with a standard error of estimate of the order of 1 to 2 ml/min/1.73 m/sup 2/. The slope-intercept method for direct estimation of glomerular filtration rate is also evaluated and found to significantly underestimate standard insulin clearance. The normalized 'single-point' method is concluded to be superior to the slope-intercept method and more sophisticated methods using curve fitting technique, with regard to predictive force and clinical applicability.

  10. A simple encapsulation method for organic optoelectronic devices

    International Nuclear Information System (INIS)

    Sun Qian-Qian; An Qiao-Shi; Zhang Fu-Jun

    2014-01-01

    The performances of organic optoelectronic devices, such as organic light emitting diodes and polymer solar cells, have rapidly improved in the past decade. The stability of an organic optoelectronic device has become a key problem for further development. In this paper, we report one simple encapsulation method for organic optoelectronic devices with a parafilm, based on ternary polymer solar cells (PSCs). The power conversion efficiencies (PCE) of PSCs with and without encapsulation decrease from 2.93% to 2.17% and from 2.87% to 1.16% after 168-hours of degradation under an ambient environment, respectively. The stability of PSCs could be enhanced by encapsulation with a parafilm. The encapsulation method is a competitive choice for organic optoelectronic devices, owing to its low cost and compatibility with flexible devices. (atomic and molecular physics)

  11. A simple method for percutaneous resection of osteoid osteoma

    International Nuclear Information System (INIS)

    Kamrani, Reza S.; Kiani, K.; Mazlouman, Shahriar J.

    2007-01-01

    To introduce a method that can be performed with minimal equipments available to most orthopedic surgeons and precludes the extensive anesthetic and ablative requirements. A percutaneous lead tunnel was first established in the cortex next to the nidus under computerized tomography guidance with local anesthesia; then the nidus was curetted in the operating room through the lead tunnel. The study was performed in Shariati Hospital in Tehran, Iran, from September 2002 to December 2005. Nineteen patients were treated with this method with 94.7% cure rate. The diagnosis was histologically confirmed in 16 cases (84.2%). Failure occurred in one patient. The patients had a mean follow-up of 13.5 months with no recurrence of symptoms with mean hospitalization time of 1.6 days. This technique is simple, minimally invasive and effective. It needs no especial equipments and provides the material for tissue diagnosis. (author)

  12. Simple Stacking Methods for Silicon Micro Fuel Cells

    Directory of Open Access Journals (Sweden)

    Gianmario Scotti

    2014-08-01

    Full Text Available We present two simple methods, with parallel and serial gas flows, for the stacking of microfabricated silicon fuel cells with integrated current collectors, flow fields and gas diffusion layers. The gas diffusion layer is implemented using black silicon. In the two stacking methods proposed in this work, the fluidic apertures and gas flow topology are rotationally symmetric and enable us to stack fuel cells without an increase in the number of electrical or fluidic ports or interconnects. Thanks to this simplicity and the structural compactness of each cell, the obtained stacks are very thin (~1.6 mm for a two-cell stack. We have fabricated two-cell stacks with two different gas flow topologies and obtained an open-circuit voltage (OCV of 1.6 V and a power density of 63 mW·cm−2, proving the viability of the design.

  13. A simple scintigraphic method for continuous monitoring of gastric emptying

    Energy Technology Data Exchange (ETDEWEB)

    Lipp, R.W.; Hammer, H.F.; Schnedl, W.; Dobnig, H.; Passath, A.; Leb, G.; Krejs, G.J. (Graz Univ. (Austria). Div. of Nuclear Medicine and Endocrinology)

    1993-03-01

    A new and simple scintigraphic method for the measurement of gastric emptying was developed and validated. The test meal consists of 200 g potato mash mixed with 0.5 g Dowex 2X8 particles (mesh 20-50) labelled with 37 MBq (1 mCi) technetium-99m. After ingestion of the meal, sequential dynamic 15-s anteroposterior exposures in the supine position are obtained for 90 min. A second recording sequence of 20 min is added after a 30-min interval. The results can be displayed as immediate cine-replay, as time-activity diagrams and/or as acitivty retention values. Complicated mathematical fittings are not necessary. The method lends itself equally to the testing of in- and outpatients. (orig.).

  14. A simple and inexpensive method for genomic restriction mapping analysis

    International Nuclear Information System (INIS)

    Huang, C.H.; Lam, V.M.S.; Tam, J.W.O.

    1988-01-01

    The Southern blotting procedure for the transfer of DNA fragments from agarose gels to nitrocellulose membranes has revolutionized nucleic acid detection methods, and it forms the cornerstone of research in molecular biology. Basically, the method involves the denaturation of DNA fragments that have been separated on an agarose gel, the immobilization of the fragments by transfer to a nitrocellulose membrane, and the identification of the fragments of interest through hybridization to /sup 32/P-labeled probes and autoradiography. While the method is sensitive and applicable to both genomic and cloned DNA, it suffers from the disadvantages of being time consuming and expensive, and fragments of greater than 15 kb are difficult to transfer. Moreover, although theoretically the nitrocellulose membrane can be washed and hybridized repeatedly using different probes, in practice, the membrane becomes brittle and difficult to handle after a few cycles. A direct hybridization method for pure DNA clones was developed in 1975 but has not been widely exploited. The authors report here a modification of their procedure as applied to genomic DNA. The method is simple, rapid, and inexpensive, and it does not involve transfer to nitrocellulose membranes

  15. A simple and efficient method to enhance audiovisual binding tendencies

    Directory of Open Access Journals (Sweden)

    Brian Odegaard

    2017-04-01

    Full Text Available Individuals vary in their tendency to bind signals from multiple senses. For the same set of sights and sounds, one individual may frequently integrate multisensory signals and experience a unified percept, whereas another individual may rarely bind them and often experience two distinct sensations. Thus, while this binding/integration tendency is specific to each individual, it is not clear how plastic this tendency is in adulthood, and how sensory experiences may cause it to change. Here, we conducted an exploratory investigation which provides evidence that (1 the brain’s tendency to bind in spatial perception is plastic, (2 that it can change following brief exposure to simple audiovisual stimuli, and (3 that exposure to temporally synchronous, spatially discrepant stimuli provides the most effective method to modify it. These results can inform current theories about how the brain updates its internal model of the surrounding sensory world, as well as future investigations seeking to increase integration tendencies.

  16. A simple gel electrophoresis method for separating polyhedral gold nanoparticles

    Science.gov (United States)

    Kim, Suhee; Lee, Hye Jin

    2015-07-01

    In this paper, a simple approach to separate differently shaped and sized polyhedral gold nanoparticles (NPs) within colloidal solutions via gel electrophoresis is described. Gel running parameters for separating efficiently gold NPs including gel composition, added surfactant types and applied voltage were investigated. The plasmonic properties and physical structure of the separated NPs extracted from the gel matrix were then investigated using transmission electron microscopy (TEM) and UV-vis spectrophotometry respectively. Data analysis revealed that gel electrophoresis conditions of a 1.5 % agarose gel with 0.1 % sodium dodecyl sulfate (SDS) surfactant under an applied voltage of 100 V resulted in the selective isolation of ~ 50 nm polyhedral shaped gold nanoparticles. Further efforts are underway to apply the method to purify biomolecule-conjugated polyhedral Au NPs that can be readily used for NP-enhanced biosensing platforms.

  17. A simple method for rapidly processing HEU from weapons returns

    Energy Technology Data Exchange (ETDEWEB)

    McLean, W. II; Miller, P.E.

    1994-01-01

    A method based on the use of a high temperature fluidized bed for rapidly oxidizing, homogenizing and down-blending Highly Enriched Uranium (HEU) from dismantled nuclear weapons is presented. This technology directly addresses many of the most important issues that inhibit progress in international commerce in HEU; viz., transaction verification, materials accountability, transportation and environmental safety. The equipment used to carry out the oxidation and blending is simple, inexpensive and highly portable. Mobile facilities to be used for point-of-sale blending and analysis of the product material are presented along with a phased implementation plan that addresses the conversion of HEU derived from domestic weapons and related waste streams as well as material from possible foreign sources such as South Africa or the former Soviet Union.

  18. New simple method for fast and accurate measurement of volumes

    International Nuclear Information System (INIS)

    Frattolillo, Antonio

    2006-01-01

    A new simple method is presented, which allows us to measure in just a few minutes but with reasonable accuracy (less than 1%) the volume confined inside a generic enclosure, regardless of the complexity of its shape. The technique proposed also allows us to measure the volume of any portion of a complex manifold, including, for instance, pipes and pipe fittings, valves, gauge heads, and so on, without disassembling the manifold at all. To this purpose an airtight variable volume is used, whose volume adjustment can be precisely measured; it has an overall capacity larger than that of the unknown volume. Such a variable volume is initially filled with a suitable test gas (for instance, air) at a known pressure, as carefully measured by means of a high precision capacitive gauge. By opening a valve, the test gas is allowed to expand into the previously evacuated unknown volume. A feedback control loop reacts to the resulting finite pressure drop, thus contracting the variable volume until the pressure exactly retrieves its initial value. The overall reduction of the variable volume achieved at the end of this process gives a direct measurement of the unknown volume, and definitively gets rid of the problem of dead spaces. The method proposed actually does not require the test gas to be rigorously held at a constant temperature, thus resulting in a huge simplification as compared to complex arrangements commonly used in metrology (gas expansion method), which can grant extremely accurate measurement but requires rather expensive equipments and results in time consuming methods, being therefore impractical in most applications. A simple theoretical analysis of the thermodynamic cycle and the results of experimental tests are described, which demonstrate that, in spite of its simplicity, the method provides a measurement accuracy within 0.5%. The system requires just a few minutes to complete a single measurement, and is ready immediately at the end of the process. The

  19. Sensitive and simple method for measuring wire tensions

    International Nuclear Information System (INIS)

    Atac, M.; Mishina, M.

    1982-08-01

    Measuring tension of wires in drift chambers and multiwire proportional chambers after construction is an important process because sometimes wires get loose after soldering, crimping or glueing. One needs to sort out wires which have tensions below a required minimum value to prevent electrostatic instabilities. There have been several methods reported on this subject in which the wires were excited either with sinusoidal current under magnetic field or with sinusoidal voltage electrostatically coupled to the wire, searching for a resonating frequency with which the wires vibrate mechanically. Then the vibration is detected either visually, optically or with magnetic pick-up directly touching the wires. Any of these is only applicable to the usual multiwire chamber which has open access to the wire plane. They also need fairly large excitation currents to induce a detectable vibration to the wires. Here we report a very simple method that can be used for any type of wire chamber or proportional tube system for measuring wire tension. Only a very small current is required for the wire excitation to obtain a large enough signal because it detects the induced emf voltage across a wire. A sine-wave oscillator and a digital voltmeter are sufficient devices aside from a permanent magnet to provide the magnetic field around the wire. A useful application of this method to a large system is suggested

  20. A simple micro-photometric method for urinary iodine determination.

    Science.gov (United States)

    Grimm, Gabriele; Lindorfer, Heidelinde; Kieweg, Heidi; Marculescu, Rodrig; Hoffmann, Martha; Gessl, Alois; Sager, Manfred; Bieglmayer, Christian

    2011-10-01

    Urinary iodide concentration (UIC) is useful to evaluate nutritional iodine status. In clinical settings UIC helps to exclude blocking of the thyroid gland by excessive endogenous iodine, if diagnostic or therapeutic administration of radio-iodine is indicated. Therefore, this study established a simple test for the measurement of UIC. UIC was analyzed in urine samples of 200 patients. Samples were pre-treated at 95°C for 45 min with ammonium persulfate in a thermal cycler, followed by a photometric Sandell-Kolthoff reaction (SK) carried out in microtiter plates. For method comparison, UIC was analyzed in 30 samples by inductivity coupled plasma mass spectro-metry (ICP-MS) as a reference method. Incubation conditions were optimized concerning recovery. The photometric test correlated well to the reference method (SK=0.91*ICP-MS+1, r=0.962) and presented with a functional sensitivity of 20 μg/L. UIC of patient samples ranged from photometric test provides satisfactory results and can be performed with the basic equipment of a clinical laboratory.

  1. A simple method for the measurement of reflective foil emissivity

    International Nuclear Information System (INIS)

    Ballico, M. J.; Ham, E. W. M. van der

    2013-01-01

    Reflective metal foil is widely used to reduce radiative heat transfer within the roof space of buildings. Such foils are typically mass-produced by vapor-deposition of a thin metallic coating onto a variety of substrates, ranging from plastic-coated reinforced paper to 'bubble-wrap'. Although the emissivity of such surfaces is almost negligible in the thermal infrared, typically less than 0.03, an insufficiently thick metal coating, or organic contamination of the surface, can significantly increase this value. To ensure that the quality of the installed insulation is satisfactory, Australian building code AS/NZS 4201.5:1994 requires a practical agreed method for measurement of the emissivity, and the standard ASTM-E408 is implied. Unfortunately this standard is not a 'primary method' and requires the use of specified expensive apparatus and calibrated reference materials. At NMIA we have developed a simple primary technique, based on an apparatus to thermally modulate the sample and record the apparent modulation in infra-red radiance with commercially available radiation thermometers. The method achieves an absolute accuracy in the emissivity of approximately 0.004 (k=2). This paper theoretically analyses the equivalence between the thermal emissivity measured in this manner, the effective thermal emissivity in application, and the apparent emissivity measured in accordance with ASTM-E408

  2. A simple method for the measurement of reflective foil emissivity

    Science.gov (United States)

    Ballico, M. J.; van der Ham, E. W. M.

    2013-09-01

    Reflective metal foil is widely used to reduce radiative heat transfer within the roof space of buildings. Such foils are typically mass-produced by vapor-deposition of a thin metallic coating onto a variety of substrates, ranging from plastic-coated reinforced paper to "bubble-wrap". Although the emissivity of such surfaces is almost negligible in the thermal infrared, typically less than 0.03, an insufficiently thick metal coating, or organic contamination of the surface, can significantly increase this value. To ensure that the quality of the installed insulation is satisfactory, Australian building code AS/NZS 4201.5:1994 requires a practical agreed method for measurement of the emissivity, and the standard ASTM-E408 is implied. Unfortunately this standard is not a "primary method" and requires the use of specified expensive apparatus and calibrated reference materials. At NMIA we have developed a simple primary technique, based on an apparatus to thermally modulate the sample and record the apparent modulation in infra-red radiance with commercially available radiation thermometers. The method achieves an absolute accuracy in the emissivity of approximately 0.004 (k=2). This paper theoretically analyses the equivalence between the thermal emissivity measured in this manner, the effective thermal emissivity in application, and the apparent emissivity measured in accordance with ASTM-E408.

  3. Simple method of measuring pulmonary extravascular water using heavy water

    Energy Technology Data Exchange (ETDEWEB)

    Basset, G; Moreau, F; Scaringella, M; Tistchenko, S; Botter, F; Marsac, J

    1975-11-20

    The field of application of the multiple indicators dilution method in human pathology, already used to study pulmonary edema, can be extended to cover the identification and testing of all conditions leading to increase lung water. To be really practical it must be simple, fast, sensitive, inexpensive and subject to repetition; the use of non-radioactive tracers is implied. Indocyanine Green and heavy water were chosen respectively as vascular and diffusible indicators. Original methods have been developed for the treatment and isotopic analysis of blood: mass spectrometric analysis of aqueous blood extracts after deproteinisation by zinc sulphate then rapid distillation of the supernatant under helium; infrared analysis either of acetone extracts from small blood samples (100..mu..litre) or of blood itself in a continuous measurement. The infrared technique adopted has been used on rats and on men in normal and pathological situations. The results show that the method proposed for the determination of pulmonary extravascular water meets the requirements of clinicians while respecting the patients' safety, and could be generalized to other organs.

  4. Simple method for generating adjustable trains of picosecond electron bunches

    Directory of Open Access Journals (Sweden)

    P. Muggli

    2010-05-01

    Full Text Available A simple, passive method for producing an adjustable train of picosecond electron bunches is demonstrated. The key component of this method is an electron beam mask consisting of an array of parallel wires that selectively spoils the beam emittance. This mask is positioned in a high magnetic dispersion, low beta-function region of the beam line. The incoming electron beam striking the mask has a time/energy correlation that corresponds to a time/position correlation at the mask location. The mask pattern is transformed into a time pattern or train of bunches when the dispersion is brought back to zero downstream of the mask. Results are presented of a proof-of-principle experiment demonstrating this novel technique that was performed at the Brookhaven National Laboratory Accelerator Test Facility. This technique allows for easy tailoring of the bunch train for a particular application, including varying the bunch width and spacing, and enabling the generation of a trailing witness bunch.

  5. A Simple Method for High-Lift Propeller Conceptual Design

    Science.gov (United States)

    Patterson, Michael; Borer, Nick; German, Brian

    2016-01-01

    In this paper, we present a simple method for designing propellers that are placed upstream of the leading edge of a wing in order to augment lift. Because the primary purpose of these "high-lift propellers" is to increase lift rather than produce thrust, these props are best viewed as a form of high-lift device; consequently, they should be designed differently than traditional propellers. We present a theory that describes how these props can be designed to provide a relatively uniform axial velocity increase, which is hypothesized to be advantageous for lift augmentation based on a literature survey. Computational modeling indicates that such propellers can generate the same average induced axial velocity while consuming less power and producing less thrust than conventional propeller designs. For an example problem based on specifications for NASA's Scalable Convergent Electric Propulsion Technology and Operations Research (SCEPTOR) flight demonstrator, a propeller designed with the new method requires approximately 15% less power and produces approximately 11% less thrust than one designed for minimum induced loss. Higher-order modeling and/or wind tunnel testing are needed to verify the predicted performance.

  6. A simple method for improving predictions of nuclear masses

    International Nuclear Information System (INIS)

    Yamada, Masami; Tsuchiya, Susumu; Tachibana, Takahiro

    1991-01-01

    The formula for atomic masses which exactly conforms to all nuclides does not exist in reality and cannot be anticipated for the time being hereafter. At present the masses of many nuclides are known experimentally with good accuracy, but the values of whichever mass formulas are more or less different from those experimental values except small number of accidental coincidence. Under such situation, for forecasting the mass of an unknown nuclide, how is it cleverly done ? Generally speaking, to take the value itself of a mass formula seems not the best means. It may be better to take the difference of the values of a mass formula and experiment for the nuclide close to that to be forecast in consideration and to correct the forecast value of the mass formula. In this report, the simple method for this correction is proposed. The formula which connects between two extreme cases, the difference between a true mass and the value of a mass formula is the sum of proton part and neutron part, and the difference distributes randomly around zero, was proposed. The procedure for its concrete application is explained. This method can be applied to other physical quantities than mass, for example the half life of beta decay. (K.I.)

  7. Laserspritzer: a simple method for optogenetic investigation with subcellular resolutions.

    Directory of Open Access Journals (Sweden)

    Qian-Quan Sun

    Full Text Available To build a detailed circuit diagram in the brain, one needs to measure functional synaptic connections between specific types of neurons. A high-resolution circuit diagram should provide detailed information at subcellular levels such as soma, distal and basal dendrites. However, a limitation lies in the difficulty of studying long-range connections between brain areas separated by millimeters. Brain slice preparations have been widely used to help understand circuit wiring within specific brain regions. The challenge exists because long-range connections are likely to be cut in a brain slice. The optogenetic approach overcomes these limitations, as channelrhodopsin 2 (ChR2 is efficiently transported to axon terminals that can be stimulated in brain slices. Here, we developed a novel fiber optic based simple method of optogenetic stimulation: the laserspritzer approach. This method facilitates the study of both long-range and local circuits within brain slice preparations. This is a convenient and low cost approach that can be easily integrated with a slice electrophysiology setup, and repeatedly used upon initial validation. Our data with direct ChR2 mediated-current recordings demonstrates that the spatial resolution of the laserspritzer is correlated with the size of the laserspritzer, and the resolution lies within the 30 µm range for the 5 micrometer laserspritzer. Using olfactory cortical slices, we demonstrated that the laserspritzer approach can be applied to selectively activate monosynaptic perisomatic GABAergic basket synapses, or long-range intracortical glutamatergic inputs formed on different subcellular domains within the same cell (e.g. distal and proximal dendrites. We discuss significant advantages of the laserspritzer approach over the widely used collimated LED whole-field illumination method in brain slice electrophysiological research.

  8. A SIMPLE AND EFFECTIVE CURSIVE WORD SEGMENTATION METHOD

    NARCIS (Netherlands)

    nicchiotti, G.; Rimassa, S.; Scagliola, C.

    2004-01-01

    A simple procedure for cursive word oversegmentation is presented, which is based on the analysis of the handwritten profiles and on the extraction of ``white holes\\'\\'. It follows the policy of using simple rules on complex data and sophisticated rules on simpler data. Experimental results show

  9. A simple graphical method for measuring inherent safety

    International Nuclear Information System (INIS)

    Gupta, J.P.; Edwards, David W.

    2003-01-01

    Inherently safer design (ISD) concepts have been with us for over two decades since their elaboration by Kletz [Chem. Ind. 9 (1978) 124]. Interest has really taken off globally since the early nineties after several major mishaps occurred during the eighties (Bhopal, Mexico city, Piper-alfa, Philips Petroleum, to name a few). Academic and industrial research personnel have been actively involved into devising inherently safer ways of production. The regulatory bodies have also shown deep interest since ISD makes the production safer and hence their tasks easier. Research funding has also been forthcoming for new developments as well as for demonstration projects. A natural question that arises is as to how to measure ISD characteristics of a process? Several researchers have worked on this [Trans. IChemE, Process Safety Environ. Protect. B 71 (4) (1993) 252; Inherent safety in process plant design, Ph.D. Thesis, VTT Publication Number 384, Helsinki University of Technology, Espoo, Finland, 1999; Proceedings of the Mary Kay O'Connor Process Safety Center Symposium, 2001, p. 509]. Many of the proposed methods are very elegant, yet too involved for easy adoption by the industry which is scared of yet another safety analysis regime. In a recent survey [Trans. IChemE, Process Safety Environ. Prog. B 80 (2002) 115], companies desired a rather simple method to measure ISD. Simplification is also an important characteristic of ISD. It is therefore desirable to have a simple ISD measurement procedure. The ISD measurement procedure proposed in this paper can be used to differentiate between two or more processes for the same end product. The salient steps are: Consider each of the important parameters affecting the safety (e.g., temperature, pressure, toxicity, flammability, etc.) and the range of possible values these parameters can have for all the process routes under consideration for an end product. Plot these values for each step in each process route and compare. No

  10. A simple method for identification of irradiated spices

    International Nuclear Information System (INIS)

    Behere, A.; Desai, S.R.P.; Nair, P.M.; Rao, S.M.D.

    1992-01-01

    Thermoluminescence (TL) properties of curry powder, a salt containing spice mixture, and three different ground spices, viz, chilli, turmeric and pepper, were compared with TL of table salt. The spices other than curry powder, did not exhibit characteristic TL in the absence of salt. Therefore studies were initiated to develop a simple and reliable method using common salt for distinguishing irradiated spices (10 kGy) from unirradiated ones under normal conditions of storage. Common salt exhibited a characteristic TL glow at 170 o C. However, when present in curry powder, the TL glow of salt showed a shift to 208 o C. It was further observed that upon storage up to 6 months, the TL of irradiated curry powder retained about 10% of the original intensity and still could be distinguished from the untreated samples. From our results it is evident that common salt could be used as an indicator either internally or externally in small sachets for incorporating into prepacked spices. (author)

  11. A simple method for identification of irradiated spices

    Energy Technology Data Exchange (ETDEWEB)

    Behere, A; Desai, S R.P.; Nair, P M [Bhabha Atomic Research Centre, Bombay (India). Food Technology and Enzyme Engineering Div.; Rao, S M.D. [Bhabha Atomic Research Centre, Bombay (India). Technical Physics and Prototype Engineering Div.

    1992-07-01

    Thermoluminescence (TL) properties of curry powder, a salt containing spice mixture, and three different ground spices, viz, chilli, turmeric and pepper, were compared with TL of table salt. The spices other than curry powder, did not exhibit characteristic TL in the absence of salt. Therefore studies were initiated to develop a simple and reliable method using common salt for distinguishing irradiated spices (10 kGy) from unirradiated ones under normal conditions of storage. Common salt exhibited a characteristic TL glow at 170{sup o}C. However, when present in curry powder, the TL glow of salt showed a shift to 208{sup o}C. It was further observed that upon storage up to 6 months, the TL of irradiated curry powder retained about 10% of the original intensity and still could be distinguished from the untreated samples. From our results it is evident that common salt could be used as an indicator either internally or externally in small sachets for incorporating into prepacked spices. (author).

  12. Simple method for culture of peripheral blood lymphocytes of Testudinidae.

    Science.gov (United States)

    Silva, T L; Silva, M I A; Venancio, L P R; Zago, C E S; Moscheta, V A G; Lima, A V B; Vizotto, L D; Santos, J R; Bonini-Domingos, C R; Azeredo-Oliveira, M T V

    2011-12-06

    We developed and optimized a simple, efficient and inexpensive method for in vitro culture of peripheral blood lymphocytes from the Brazilian tortoise Chelonoidis carbonaria (Testudinidae), testing various parameters, including culture medium, mitogen concentration, mitotic index, culture volume, incubation time, and mitotic arrest. Peripheral blood samples were obtained from the costal vein of four couples. The conditions that gave a good mitotic index were lymphocytes cultured at 37°C in minimum essential medium (7.5 mL), with phytohemagglutinin as a mitogen (0.375 mL), plus streptomycin/penicillin (0.1 mL), and an incubation period of 72 h. Mitotic arrest was induced by 2-h exposure to colchicine (0.1 mL), 70 h after establishing the culture. After mitotic arrest, the cells were hypotonized with 0.075 M KCl for 2 h and fixed with methanol/acetic acid (3:1). The non-banded mitotic chromosomes were visualized by Giemsa staining. The diploid chromosome number of C. carbonaria was found to be 52 in females and males, and sex chromosomes were not observed. We were able to culture peripheral blood lymphocytes of a Brazilian tortoise in vitro, for the preparation of mitotic chromosomes.

  13. Simple method of generating and distributing frequency-entangled qudits

    Science.gov (United States)

    Jin, Rui-Bo; Shimizu, Ryosuke; Fujiwara, Mikio; Takeoka, Masahiro; Wakabayashi, Ryota; Yamashita, Taro; Miki, Shigehito; Terai, Hirotaka; Gerrits, Thomas; Sasaki, Masahide

    2016-11-01

    High-dimensional, frequency-entangled photonic quantum bits (qudits for d-dimension) are promising resources for quantum information processing in an optical fiber network and can also be used to improve channel capacity and security for quantum communication. However, up to now, it is still challenging to prepare high-dimensional frequency-entangled qudits in experiments, due to technical limitations. Here we propose and experimentally implement a novel method for a simple generation of frequency-entangled qudts with d\\gt 10 without the use of any spectral filters or cavities. The generated state is distributed over 15 km in total length. This scheme combines the technique of spectral engineering of biphotons generated by spontaneous parametric down-conversion and the technique of spectrally resolved Hong-Ou-Mandel interference. Our frequency-entangled qudits will enable quantum cryptographic experiments with enhanced performances. This distribution of distinct entangled frequency modes may also be useful for improved metrology, quantum remote synchronization, as well as for fundamental test of stronger violation of local realism.

  14. Cumulants in perturbation expansions for non-equilibrium field theory

    International Nuclear Information System (INIS)

    Fauser, R.

    1995-11-01

    The formulation of perturbation expansions for a quantum field theory of strongly interacting systems in a general non-equilibrium state is discussed. Non-vanishing initial correlations are included in the formulation of the perturbation expansion in terms of cumulants. The cumulants are shown to be the suitable candidate for summing up the perturbation expansion. Also a linked-cluster theorem for the perturbation series with cumulants is presented. Finally a generating functional of the perturbation series with initial correlations is studied. We apply the methods to a simple model of a fermion-boson system. (orig.)

  15. A SIMPLE METHOD FOR THE EXTRACTION AND QUANTIFICATION OF PHOTOPIGMENTS FROM SYMBIODINIUM SPP.

    Science.gov (United States)

    John E. Rogers and Dragoslav Marcovich. Submitted. Simple Method for the Extraction and Quantification of Photopigments from Symbiodinium spp.. Limnol. Oceanogr. Methods. 19 p. (ERL,GB 1192). We have developed a simple, mild extraction procedure using methanol which, when...

  16. A simple objective method for determining a dynamic journal collection.

    Science.gov (United States)

    Bastille, J D; Mankin, C J

    1980-10-01

    In order to determine the content of a journal collection responsive to both user needs and space and dollar constraints, quantitative measures of the use of a 647-title collection have been related to space and cost requirements to develop objective criteria for a dynamic collection for the Treadwell Library at the Massachusetts General Hospital, a large medical research center. Data were collected for one calendar year (1977) and stored with the elements for each title's profile in a computerized file. To account for the effect of the bulk of the journal runs on the number of uses, raw use data have been adjusted using linear shelf space required for each title to produce a factor called density of use. Titles have been ranked by raw use and by density of use with space and cost requirements for each. Data have also been analyzed for five special categories of use. Given automated means of collecting and storing data, use measures should be collected continuously. Using raw use frequency ranking to relate use to space and costs seems sensible since a decision point cutoff can be chosen in terms of the potential interlibrary loans generated. But it places new titles at risk while protecting titles with long, little used runs. Basing decisions on density of use frequency ranking seems to produce a larger yield of titles with fewer potential interlibrary loans and to identify titles with overlong runs which may be pruned or converted to microform. The method developed is simple and practical. Its design will be improved to apply to data collected in 1980 for a continuous study of journal use. The problem addressed is essentially one of inventory control. Viewed as such it makes good financial sense to measure use as part of the routine operation of the library to provide information for effective management decisions.

  17. Possibilities and consequences of the Total Cumulative Exergy Loss method in improving the sustainability of power generation

    International Nuclear Information System (INIS)

    Stougie, Lydia; Kooi, Hedzer J. van der

    2016-01-01

    Highlights: • The TCExL method can be applied to all kinds of technological systems. • All exergy losses during the lifetime of a technological system are considered. • The results of the TCExL method are independent of time and weighting factors. • Applying the TCExL method can improve the sustainability of power generation. • The system with the lowest TCExL score is not always economically favourable. - Abstract: It is difficult to decide which power generation system is the most sustainable when environmental, economic and social sustainability aspects are taken into account. Problems with conventional environmental sustainability assessment methods are that no consensus exists about the applied models and weighting factors and that exergy losses are not considered. Economic sustainability assessment methods do not lead to results that are independent of time because they are influenced by market developments, while social sustainability assessment methods suffer from the availability and qualitative or semi-quantitative nature of data. Existing exergy analysis methods do not take into account all exergy losses and/or are extended with factors or equations that are not commonly accepted. The new Total Cumulative Exergy Loss (TCExL) method is based on fundamental thermodynamic equations and takes into account all exergy losses caused by a technological system during its life cycle, i.e. internal exergy losses, exergy losses caused by emission abatement and exergy losses related to land use. The development of the TCExL method is presented as well as the application of this method and environmental, economic and social sustainability assessment methods to two case studies: power generation in combination with LNG evaporation and Fossil versus renewable energy sources for power generation. According to the results of the assessments, large differences exist between the environmental sustainability assessment and TCExL methods in the sense that different

  18. A CUMULATIVE MIGRATION METHOD FOR COMPUTING RIGOROUS TRANSPORT CROSS SECTIONS AND DIFFUSION COEFFICIENTS FOR LWR LATTICES WITH MONTE CARLO

    Energy Technology Data Exchange (ETDEWEB)

    Zhaoyuan Liu; Kord Smith; Benoit Forget; Javier Ortensi

    2016-05-01

    A new method for computing homogenized assembly neutron transport cross sections and dif- fusion coefficients that is both rigorous and computationally efficient is proposed in this paper. In the limit of a homogeneous hydrogen slab, the new method is equivalent to the long-used, and only-recently-published CASMO transport method. The rigorous method is used to demonstrate the sources of inaccuracy in the commonly applied “out-scatter” transport correction. It is also demonstrated that the newly developed method is directly applicable to lattice calculations per- formed by Monte Carlo and is capable of computing rigorous homogenized transport cross sections for arbitrarily heterogeneous lattices. Comparisons of several common transport cross section ap- proximations are presented for a simple problem of infinite medium hydrogen. The new method has also been applied in computing 2-group diffusion data for an actual PWR lattice from BEAVRS benchmark.

  19. A simple time-delayed method to control chaotic systems

    International Nuclear Information System (INIS)

    Chen Maoyin; Zhou Donghua; Shang Yun

    2004-01-01

    Based on the adaptive iterative learning strategy, a simple time-delayed controller is proposed to stabilize unstable periodic orbits (UPOs) embedded in chaotic attractors. This controller includes two parts: one is a linear feedback part; the other is an adaptive iterative learning estimation part. Theoretical analysis and numerical simulation show the effectiveness of this controller

  20. Monitoring the quality of total hip replacement in a tertiary care department using a cumulative summation statistical method (CUSUM).

    Science.gov (United States)

    Biau, D J; Meziane, M; Bhumbra, R S; Dumaine, V; Babinet, A; Anract, P

    2011-09-01

    The purpose of this study was to define immediate post-operative 'quality' in total hip replacements and to study prospectively the occurrence of failure based on these definitions of quality. The evaluation and assessment of failure were based on ten radiological and clinical criteria. The cumulative summation (CUSUM) test was used to study 200 procedures over a one-year period. Technical criteria defined failure in 17 cases (8.5%), those related to the femoral component in nine (4.5%), the acetabular component in 32 (16%) and those relating to discharge from hospital in five (2.5%). Overall, the procedure was considered to have failed in 57 of the 200 total hip replacements (28.5%). The use of a new design of acetabular component was associated with more failures. For the CUSUM test, the level of adequate performance was set at a rate of failure of 20% and the level of inadequate performance set at a failure rate of 40%; no alarm was raised by the test, indicating that there was no evidence of inadequate performance. The use of a continuous monitoring statistical method is useful to ensure that the quality of total hip replacement is maintained, especially as newer implants are introduced.

  1. Use of the cumulative sum method (CUSUM) to assess the learning curves of ultrasound-guided continuous femoral nerve block.

    Science.gov (United States)

    Kollmann-Camaiora, A; Brogly, N; Alsina, E; Gilsanz, F

    2017-10-01

    Although ultrasound is a basic competence for anaesthesia residents (AR) there is few data available on the learning process. This prospective observational study aims to assess the learning process of ultrasound-guided continuous femoral nerve block and to determine the number of procedures that a resident would need to perform in order to reach proficiency using the cumulative sum (CUSUM) method. We recruited 19 AR without previous experience. Learning curves were constructed using the CUSUM method for ultrasound-guided continuous femoral nerve block considering 2 success criteria: a decrease of pain score>2 in a [0-10] scale after 15minutes, and time required to perform it. We analyse data from 17 AR for a total of 237 ultrasound-guided continuous femoral nerve blocks. 8/17 AR became proficient for pain relief, however all the AR who did more than 12 blocks (8/8) became proficient. As for time of performance 5/17 of AR achieved the objective of 12minutes, however all the AR who did more than 20 blocks (4/4) achieved it. The number of procedures needed to achieve proficiency seems to be 12, however it takes more procedures to reduce performance time. The CUSUM methodology could be useful in training programs to allow early interventions in case of repeated failures, and develop competence-based curriculum. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. A Simple Introduction to Grobner Basis Methods in String Phenomenology

    International Nuclear Information System (INIS)

    Gray, J.

    2011-01-01

    I give an elementary introduction to the key algorithm used in recent applications of computational algebraic geometry to the subject of string phenomenology. I begin with a simple description of the algorithm itself and then give 3 examples of its use in physics. I describe how it can be used to obtain constraints on flux parameters, how it can simplify the equations describing vacua in 4D string models, and lastly how it can be used to compute the vacuum space of the electroweak sector of the MSSM.

  3. Simple methods for the 3' biotinylation of RNA.

    Science.gov (United States)

    Moritz, Bodo; Wahle, Elmar

    2014-03-01

    Biotinylation of RNA allows its tight coupling to streptavidin and is thus useful for many types of experiments, e.g., pull-downs. Here we describe three simple techniques for biotinylating the 3' ends of RNA molecules generated by chemical or enzymatic synthesis. First, extension with either the Schizosaccharomyces pombe noncanonical poly(A) polymerase Cid1 or Escherichia coli poly(A) polymerase and N6-biotin-ATP is simple, efficient, and generally applicable independently of the 3'-end sequences of the RNA molecule to be labeled. However, depending on the enzyme and the reaction conditions, several or many biotinylated nucleotides are incorporated. Second, conditions are reported under which splint-dependent ligation by T4 DNA ligase can be used to join biotinylated and, presumably, other chemically modified DNA oligonucleotides to RNA 3' ends even if these are heterogeneous as is typical for products of enzymatic synthesis. Third, we describe the use of 29 DNA polymerase for a template-directed fill-in reaction that uses biotin-dUTP and, thanks to the enzyme's proofreading activity, can cope with more extended 3' heterogeneities.

  4. A simple method for solving the inverse scattering problem

    International Nuclear Information System (INIS)

    Melnikov, V.N.; Rudyak, B.V.; Zakhariev, V.N.

    1977-01-01

    A new method is proposed for approximate reconstruction of a potential as a step function from scattering data using the completeness relation of solutions of the Schroedinger equation. The suggested method allows one to take into account exactly the additional centrifugal barrier for partial waves with angular momentum l>0, and also the Coulomb potential. The method admits different generalizations. Numerical calculations for checking the method have been performed

  5. A simple method for stem cell labeling with fluorine 18

    International Nuclear Information System (INIS)

    Ma Bing; Hankenson, Kurt D.; Dennis, James E.; Caplan, Arnold I.; Goldstein, Steven A.; Kilbourn, Michael R.

    2005-01-01

    Hexadecyl-4-[ 18 F]fluorobenzoate ([ 18 F]HFB), a long chain fluorinated benzoic acid ester, was prepared in a one-step synthesis by aromatic nucleophilic substitution of [ 18 F]fluoride ion on hexadecyl-4-(N,N,N-trimethylammonio)benzoate. The radiolabeled ester was obtained in good yields (52% decay corrected) and high purity (97%). [ 18 F]HFB was used to radiolabel rat mesenchymal stem cells (MSCs) by absorption into cell membranes. MicroPET imaging of [ 18 F]HFB-labeled MSCs following intravenous injection into the rat showed the expected high and persistent accumulation of radioactivity in the lungs. [ 18 F]HFB is thus simple to prepare and uses labeling agent for short-term distribution studies of injected stem cells

  6. A simple method for stem cell labeling with fluorine 18

    Energy Technology Data Exchange (ETDEWEB)

    Ma Bing [Department of Radiology, Division of Nuclear Medicine, University of Michigan Medical School, Ann Arbor, MI 48109 (United States); Hankenson, Kurt D. [Department of Biology, Case Western Reserve University, Cleveland, OH 44106 (United States); Dennis, James E. [Department of Biology, Case Western Reserve University, Cleveland, OH 44106 (United States); Caplan, Arnold I. [Department of Biology, Case Western Reserve University, Cleveland, OH 44106 (United States); Goldstein, Steven A. [Department of Orthopaedic Surgery, University of Michigan Medical School, Ann Arbor, MI 48109 (United States); Kilbourn, Michael R. [Department of Radiology, Division of Nuclear Medicine, University of Michigan Medical School, Ann Arbor, MI 48109 (United States)

    2005-10-01

    Hexadecyl-4-[{sup 18}F]fluorobenzoate ([{sup 18}F]HFB), a long chain fluorinated benzoic acid ester, was prepared in a one-step synthesis by aromatic nucleophilic substitution of [{sup 18}F]fluoride ion on hexadecyl-4-(N,N,N-trimethylammonio)benzoate. The radiolabeled ester was obtained in good yields (52% decay corrected) and high purity (97%). [{sup 18}F]HFB was used to radiolabel rat mesenchymal stem cells (MSCs) by absorption into cell membranes. MicroPET imaging of [{sup 18}F]HFB-labeled MSCs following intravenous injection into the rat showed the expected high and persistent accumulation of radioactivity in the lungs. [{sup 18}F]HFB is thus simple to prepare and uses labeling agent for short-term distribution studies of injected stem cells.

  7. A Rapid and Simple Bioassay Method for Herbicide Detection

    Directory of Open Access Journals (Sweden)

    Xiu-Qing Li

    2008-01-01

    Full Text Available Chlamydomonas reinhardtii, a unicellular green alga, has been used in bioassay detection of a variety of toxic compounds such as pesticides and toxic metals, but mainly using liquid culture systems. In this study, an algal lawn--agar system for semi-quantitative bioassay of herbicidal activities has been developed. Sixteen different herbicides belonging to 11 different categories were applied to paper disks and placed on green alga lawns in Petri dishes. Presence of herbicide activities was indicated by clearing zones around the paper disks on the lawn 2-3 days after application. The different groups of herbicides induced clearing zones of variable size that depended on the amount, mode of action, and chemical properties of the herbicides applied to the paper disks. This simple, paper-disk-algal system may be used to detect the presence of herbicides in water samples and act as a quick and inexpensive semi-quantitative screening for assessing herbicide contamination.

  8. Simple, rapid method for the preparation of isotopically labeled formaldehyde

    Science.gov (United States)

    Hooker, Jacob Matthew [Port Jefferson, NY; Schonberger, Matthias [Mains, DE; Schieferstein, Hanno [Aabergen, DE; Fowler, Joanna S [Bellport, NY

    2011-10-04

    Isotopically labeled formaldehyde (*C.sup..sctn.H.sub.2O) is prepared from labeled methyl iodide (*C.sup..sctn.H.sub.3I) by reaction with an oxygen nucleophile having a pendant leaving group. The mild and efficient reaction conditions result in good yields of *C.sup..sctn.H.sub.2O with little or no *C isotopic dilution. The simple, efficient production of .sup.11CH.sub.2O is described. The use of the .sup.11CH.sub.2O for the formation of positron emission tomography tracer compounds is described. The reaction can be incorporated into automated equipment available to radiochemistry laboratories. The isotopically labeled formaldehyde can be used in a variety of reactions to provide radiotracer compounds for imaging studies as well as for scintillation counting and autoradiography.

  9. Introducing a simple and economical method to purify Giardia ...

    African Journals Online (AJOL)

    Jane

    2011-08-08

    Aug 8, 2011 ... two-phase method was 1.5 × 104 cysts for each two grams of fecal sample. In this ... is a mélange of them with some changes. ... MATERIALS AND METHODS ... than 8 cysts in each microscopic field with the magnification of ×.

  10. A Simple and Accurate Method for Measuring Enzyme Activity.

    Science.gov (United States)

    Yip, Din-Yan

    1997-01-01

    Presents methods commonly used for investigating enzyme activity using catalase and presents a new method for measuring catalase activity that is more reliable and accurate. Provides results that are readily reproduced and quantified. Can also be used for investigations of enzyme properties such as the effects of temperature, pH, inhibitors,…

  11. A simple method for purification of herpesvirus DNA

    DEFF Research Database (Denmark)

    Christensen, Laurids Siig; Normann, Preben

    1992-01-01

    A rapid and reliable method for purification of herpesvirus DNA from cell cultures is described. The method is based on the isolation of virus particles and/or nucleocapsids by differential centrifugation and exploits the solubilizing and denaturing capabilities of cesium trifluoroacetate during...

  12. A simple eigenfunction convergence acceleration method for Monte Carlo

    International Nuclear Information System (INIS)

    Booth, Thomas E.

    2011-01-01

    Monte Carlo transport codes typically use a power iteration method to obtain the fundamental eigenfunction. The standard convergence rate for the power iteration method is the ratio of the first two eigenvalues, that is, k_2/k_1. Modifications to the power method have accelerated the convergence by explicitly calculating the subdominant eigenfunctions as well as the fundamental. Calculating the subdominant eigenfunctions requires using particles of negative and positive weights and appropriately canceling the negative and positive weight particles. Incorporating both negative weights and a ± weight cancellation requires a significant change to current transport codes. This paper presents an alternative convergence acceleration method that does not require modifying the transport codes to deal with the problems associated with tracking and cancelling particles of ± weights. Instead, only positive weights are used in the acceleration method. (author)

  13. A rapid, simple method for obtaining radiochemically pure hepatic heme

    International Nuclear Information System (INIS)

    Bonkowski, H.L.; Bement, W.J.; Erny, R.

    1978-01-01

    Radioactively-labelled heme has usually been isolated from liver to which unlabelled carrier has been added by long, laborious techniques involving organic solvent extraction followed by crystallization. A simpler, rapid method is devised for obtaining radiochemically-pure heme synthesized in vivo in rat liver from delta-amino[4- 14 C]levulinate. This method, in which the heme is extracted into ethyl acetate/glacial acetic acid and in which porphyrins are removed from the heme-containing organic phase with HCl washes, does not require addition of carrier heme. The new method gives better heme recoveries than and heme specific activities identical to, those obtained using the crystallization method. In this new method heme must be synthesized from delta-amino[4- 14 C]levulinate; it is not satisfactory to use [2- 14 C]glycine substrate because non-heme counts are isolated in the heme fraction. (Auth.)

  14. A Simple Method for Identifying the Acromioclavicular Joint During Arthroscopic Procedures

    OpenAIRE

    Javed, Saqib; Heasley, Richard; Ravenscroft, Matt

    2013-01-01

    Arthroscopic acromioclavicular joint excision is performed via an anterior portal and is technically demanding. We present a simple method for identifying the acromioclavicular joint during arthroscopic procedures.

  15. A simple and rapid molecular method for Leptospira species identification

    NARCIS (Netherlands)

    Ahmed, Ahmed; Anthony, Richard M.; Hartskeerl, Rudy A.

    2010-01-01

    Serological and DNA-based classification systems only have little correlation. Currently serological and molecular methods for characterizing Leptospira are complex and costly restricting their world-wide distribution and use. Ligation mediated amplification combined with microarray analysis

  16. A simple method for potential flow simulation of cascades

    Indian Academy of Sciences (India)

    vortex panel method to simulate potential flow in cascades is presented. The cascade ... The fluid loading on the blades, such as the normal force and pitching moment, may ... of such discrete infinite array singularities along the blade surface.

  17. A simple method for estimating the convection- dispersion equation ...

    African Journals Online (AJOL)

    Jane

    2011-08-31

    Aug 31, 2011 ... approach of modeling solute transport in porous media uses the deterministic ... Methods of estimating CDE transport parameters can be divided into statistical ..... diffusion-type model for longitudinal mixing of fluids in flow.

  18. A Simple Deep Learning Method for Neuronal Spike Sorting

    Science.gov (United States)

    Yang, Kai; Wu, Haifeng; Zeng, Yu

    2017-10-01

    Spike sorting is one of key technique to understand brain activity. With the development of modern electrophysiology technology, some recent multi-electrode technologies have been able to record the activity of thousands of neuronal spikes simultaneously. The spike sorting in this case will increase the computational complexity of conventional sorting algorithms. In this paper, we will focus spike sorting on how to reduce the complexity, and introduce a deep learning algorithm, principal component analysis network (PCANet) to spike sorting. The introduced method starts from a conventional model and establish a Toeplitz matrix. Through the column vectors in the matrix, we trains a PCANet, where some eigenvalue vectors of spikes could be extracted. Finally, support vector machine (SVM) is used to sort spikes. In experiments, we choose two groups of simulated data from public databases availably and compare this introduced method with conventional methods. The results indicate that the introduced method indeed has lower complexity with the same sorting errors as the conventional methods.

  19. The simple method of determination peaks areas in multiplets

    International Nuclear Information System (INIS)

    Loska, L.; Ptasinski, J.

    1991-01-01

    Semiconductor germanium detectors used in γ-spectrometry give spectra with well-separated peaks. However, in some cases, energies of γ-lines are too near, to produce resolved and undisturbed peaks. Then, there is a necessity to perform a mathematical separation. The method proposed here is based on the assumption, that areas of peaks composing the analysed multiplet are proportional to their heights. The method can be applied for any number of interfering peaks, providing, that the function of the background under the multiplet is accurately determined. The results of testing calculations performed on a simulated spectrum are given. The method works successfully in a computer program used for neutron activation analysis data processing. (author). 9 refs, 1 fig, 1 tab

  20. A simple method of injecting tumescent fluid for liposuction

    Directory of Open Access Journals (Sweden)

    Arindam Sarkar

    2011-01-01

    Full Text Available Injection of tumescent fluid is essential to obtain a painless and relatively bloodless liposuction. There are many methods of injecting the tumescent fluid like power pumps, syringes and pressure cuffs. Our method consists of applying air pressure within the plastic transfusion fluid bottle by pricking with a wide bore needle and connecting it to a sphygmomanometer balloon pump. By inflation of the balloon pump and thus increasing pressure inside the plastic bottle, the rate and volume of infusion can be controlled. By applying the cuff outside the bottle the visibility inside is impaired and the bottle gets collapsed preventing a continued pressure and thereby impairing both the quantity as well as the rate of infusion. Power pumps are expensive. This method is inexpensive, infused volume of fluid being visible and the rate of infusion controllable.

  1. Simple design of slanted grating with simplified modal method.

    Science.gov (United States)

    Li, Shubin; Zhou, Changhe; Cao, Hongchao; Wu, Jun

    2014-02-15

    A simplified modal method (SMM) is presented that offers a clear physical image for subwavelength slanted grating. The diffraction characteristic of the slanted grating under Littrow configuration is revealed by the SMM as an equivalent rectangular grating, which is in good agreement with rigorous coupled-wave analysis. Based on the equivalence, we obtained an effective analytic solution for simplifying the design and optimization of a slanted grating. It offers a new approach for design of the slanted grating, e.g., a 1×2 beam splitter can be easily designed. This method should be helpful for designing various new slanted grating devices.

  2. siMS Score: Simple Method for Quantifying Metabolic Syndrome

    OpenAIRE

    Soldatovic, Ivan; Vukovic, Rade; Culafic, Djordje; Gajic, Milan; Dimitrijevic-Sreckovic, Vesna

    2016-01-01

    Objective To evaluate siMS score and siMS risk score, novel continuous metabolic syndrome scores as methods for quantification of metabolic status and risk. Materials and Methods Developed siMS score was calculated using formula: siMS score = 2*Waist/Height + Gly/5.6 + Tg/1.7 + TAsystolic/130?HDL/1.02 or 1.28 (for male or female subjects, respectively). siMS risk score was calculated using formula: siMS risk score = siMS score * age/45 or 50 (for male or female subjects, respectively) * famil...

  3. Simple picrate method for the determination of cyanide in cassava ...

    African Journals Online (AJOL)

    The red coloured complex on the strips was extracted with 50% ethanol solution and the absorbance of the extract was measured at 510nm using a spectrophotometer. The method was reproducible and cyanide as low as 1 microgram could be determined. Cyanide levels of all the cassava varieties tested were higher than ...

  4. A simple reliability block diagram method for safety integrity verification

    International Nuclear Information System (INIS)

    Guo Haitao; Yang Xianhui

    2007-01-01

    IEC 61508 requires safety integrity verification for safety related systems to be a necessary procedure in safety life cycle. PFD avg must be calculated to verify the safety integrity level (SIL). Since IEC 61508-6 does not give detailed explanations of the definitions and PFD avg calculations for its examples, it is difficult for common reliability or safety engineers to understand when they use the standard as guidance in practice. A method using reliability block diagram is investigated in this study in order to provide a clear and feasible way of PFD avg calculation and help those who take IEC 61508-6 as their guidance. The method finds mean down times (MDTs) of both channel and voted group first and then PFD avg . The calculated results of various voted groups are compared with those in IEC61508 part 6 and Ref. [Zhang T, Long W, Sato Y. Availability of systems with self-diagnostic components-applying Markov model to IEC 61508-6. Reliab Eng System Saf 2003;80(2):133-41]. An interesting outcome can be realized from the comparison. Furthermore, although differences in MDT of voted groups exist between IEC 61508-6 and this paper, PFD avg of voted groups are comparatively close. With detailed description, the method of RBD presented can be applied to the quantitative SIL verification, showing a similarity of the method in IEC 61508-6

  5. Assay of spent fuel by a simple reactivity method

    International Nuclear Information System (INIS)

    Lee, D.M.; Lindquist, L.O.

    1982-01-01

    A new method for the assay of spent-fuel assemblies has been developed that eliminates the need for external isotopic neutron sources, yet retains the advantages of an active interrogation system. The assay is accomplished by changing the reactivity of the system and correlating the measurements to burnup. 7 figures

  6. A Simple Alternative Method for the Synthesis of Aromatic Dialdehydes

    OpenAIRE

    KOZ, Gamze; ASTLEY, Demet; ASTLEY, Stephen

    2011-01-01

    Aromatic dialdehydes were synthesized from 5-t-butylsalicylaldehyde and o-vanilline in good yields using paraformaldehyde, hydrobromic acid and catalytic amounts of sulfuric acid in one step which was previously unavailable with present methods. Key Words: aromatic dialdehydes, bromomethylation, 5-t-butylsalicylaldehyde, o-vanilline. 

  7. A Simple Alternative Method for the Synthesis of Aromatic Dialdehydes

    OpenAIRE

    KOZ, Gamze; ASTLEY, Demet; ASTLEY, Stephen Thomas

    2012-01-01

    Aromatic dialdehydes were synthesized from 5-t-butylsalicylaldehyde and o-vanilline in good yields using paraformaldehyde, hydrobromic acid and catalytic amounts of sulfuric acid in one step which was previously unavailable with present methods. Key Words: aromatic dialdehydes, bromomethylation, 5-t-butylsalicylaldehyde, o-vanilline. 

  8. Simple and efficient methods for isolation and activity measurement ...

    African Journals Online (AJOL)

    Jane

    2011-06-29

    Jun 29, 2011 ... Key words: Hirudin, thrombin titration method, chromatography, purification. INTRODUCTION. Since recombinant ... Escherichia coli in 1986, intensive research had been .... mixed with 50 µl sample was incubated in 37°C water for 5 min, then 5 µl .... conclusion, the concise and efficient isolation line of the.

  9. A Simple UV Spectrophotometric Method for the Determination of ...

    African Journals Online (AJOL)

    The method was also used in the determination of the content of levofloxacin in two commercial brands of levofloxacin in the Nigerian market. Results: The regression data for the calibration plots exhibited good linear relationship (r = 0.999) over a concentration range of 0.25 – 12.0 ìg/ml and the linear regression equation ...

  10. Simple method to calculate percolation, Ising and Potts clusters

    International Nuclear Information System (INIS)

    Tsallis, C.

    1981-01-01

    A procedure ('break-collapse method') is introduced which considerably simplifies the calculation of two - or multirooted clusters like those commonly appearing in real space renormalization group (RG) treatments of bond-percolation, and pure and random Ising and Potts problems. The method is illustrated through two applications for the q-state Potts ferromagnet. The first of them concerns a RG calculation of the critical exponent ν for the isotropic square lattice: numerical consistence is obtained (particularly for q→0) with den Nijs conjecture. The second application is a compact reformulation of the standard star-triangle and duality transformations which provide the exact critical temperature for the anisotropic triangular and honeycomb lattices. (Author) [pt

  11. Captive solvent methods for fast, simple carbon-11 radioalkylations

    International Nuclear Information System (INIS)

    Jewett, D.M.; Mangner, T.J.; Watkins, G.L.

    1991-01-01

    Carbon-11 labeled radiopharmaceuticals for receptor studies usually require final purification by high performance liquid chromatography (HPLC). A significant simplification of the apparatus is possible if the radiolabeling reaction can be done directly in the HPLC injection circuit. Captive solvent methods in which the reaction is done in a small volume of solvent absorbed in a porous solid matrix are a general approach to this problem. For N-methylations with [ 11 C] methyl iodide, a basic catalyst may be incorporated in the polymeric or alumina solid phase. Reaction volumes are from 20 to 100 ML. Often no heating or cooling of the reaction column is necessary. The syntheses of [ 11 C]PK11195 and [ 11 C] flumazenil are described to illustrate some of the advantages and limitations of captive solvent methods

  12. A method of solving simple harmonic oscillator Schroedinger equation

    Science.gov (United States)

    Maury, Juan Carlos F.

    1995-01-01

    A usual step in solving totally Schrodinger equation is to try first the case when dimensionless position independent variable w is large. In this case the Harmonic Oscillator equation takes the form (d(exp 2)/dw(exp 2) - w(exp 2))F = 0, and following W.K.B. method, it gives the intermediate corresponding solution F = exp(-w(exp 2)/2), which actually satisfies exactly another equation, (d(exp 2)/dw(exp 2) + 1 - w(exp 2))F = 0. We apply a different method, useful in anharmonic oscillator equations, similar to that of Rampal and Datta, and although it is slightly more complicated however it is also more general and systematic.

  13. Standardized methods for photography in procedural dermatology using simple equipment.

    Science.gov (United States)

    Hexsel, Doris; Hexsel, Camile L; Dal'Forno, Taciana; Schilling de Souza, Juliana; Silva, Aline F; Siega, Carolina

    2017-04-01

    Photography is an important tool in dermatology. Reproducing the settings of before photos after interventions allows more accurate evaluation of treatment outcomes. In this article, we describe standardized methods and tips to obtain photographs, both for clinical practice and research procedural dermatology, using common equipment. Standards for the studio, cameras, photographer, patients, and framing are presented in this article. © 2017 The International Society of Dermatology.

  14. Simple Room Temperature Method for Polymer Optical Fibre Cleaving

    DEFF Research Database (Denmark)

    Saez-Rodriguez, David; Nielsen, Kristian; Bang, Ole

    2015-01-01

    In this paper, we report on a new method to cleave polymer optical fibre. The most common way to cut a polymer optical fibre is chopping it with a razor blade; however, in this approach both the fibre and the blade must be preheated in order to turn the material ductile, and thus, prevent crazing...... of similar quality to those produced by more complex and expensive heated systems....

  15. A simple method for calculation of Glauber's amplitude

    International Nuclear Information System (INIS)

    Omboo, Z.

    1983-01-01

    A method of calculating the terms of Glauber series expansions for elastic scattering of composed systems are presented. The inclusion of general scattering diagram simplifies essentially the calculation procedure. In this case the complicated combinatorical problem of reduction of similar terms in Glauber series is solved easily and determinant corresponding to various terms of the series decreases at least by a factor of two, if numbers of constituents of scattered systems are equal. If these numbers are not equal, the determinant order is equal to the smallest one

  16. Simple method for measuring reflectance of optical coatings

    International Nuclear Information System (INIS)

    Wen Gui Wang; Yi Sheng Chen

    1995-01-01

    The quality of optical coatings has an important effect on the performance of optical instrument. The last few years, the requirements for super low loss dielectric mirror coatings used in low gain laser systems such as free electron laser and the ring laser etc., have given an impetus to the development of the technology of precise reflectance measurement of optical coatings. A reliable and workable technique is to measure the light intensity decay time of optical resonant cavity. This paper describes a measuring method which is dependent on direct measurement of the light intensity decay time of a resonant cavity comprised of low loss optical components. According to the evolution of a luminous flux stored inside the cavity, this method guarantees not only a quick and precise reflectance measurements of low loss highly reflecting mirror coatings but also transmittance measurements of low loss antireflection coatings and is especially effective with super los loss highly reflecting mirror. From the round-trip path length of the cavity and the speed of light, the light intensity exponential decay time of an optical cavity is easy to obtain and the cavity losses can be deduced. An optical reflectance of low loss highly mirror coatings and antireflection coatings is precisely measured as well. This is highly significant for the discrimination of the coating surface characteristics, the improvement of the performance of optical instrument and the development of high technology

  17. Simple measuring rod method for the coaxiality of serial holes

    Science.gov (United States)

    Wang, Lei; Yang, Tongyu; Wang, Zhong; Ji, Yuchen; Liu, Changjie; Fu, Luhua

    2017-11-01

    Aiming at the rapid coaxiality measurement of serial hole part with a small diameter, a coaxiality measuring rod for each layer hole with a single LDS (laser displacement sensor) is proposed. This method does not require the rotation angle information of the rod, and the coaxiality of serial holes can be calculated from the measured values of LDSs after randomly rotating the measuring rod several times. With the mathematical model of the coaxiality measuring rod, each factor affecting the accuracy of coaxiality measurement is analyzed by simulation, and the installation accuracy requirements of the measuring rod and LDSs are presented. In the tolerance of a certain installation error of the measuring rod, the relative center of the hole is calculated by setting the over-determined nonlinear equations of the fitting circles of the multi-layer holes. In experiment, coaxiality measurement accuracy is realized by a 16 μm precision LDS, and the validity of the measurement method is verified. The manufacture and measurement requirements of the coaxiality measuring rod are low, by changing the position of LDSs in the measuring rod, the serial holes with different sizes and numbers can be measured. The rapid coaxiality measurement of parts can be easily implemented in industrial sites.

  18. Some new, simple and efficient stereological methods and their use in pathological research and diagnosis

    DEFF Research Database (Denmark)

    Gundersen, H J; Bendtsen, T F; Korbo, L

    1988-01-01

    Stereology is a set of simple and efficient methods for quantitation of three-dimensional microscopic structures which is specifically tuned to provide reliable data from sections. Within the last few years, a number of new methods has been developed which are of special interest to pathologists...... are invariably simple and easy....

  19. Simple discretization method for autoionization widths. III. Molecules

    International Nuclear Information System (INIS)

    Macas, A.; Martn, F.; Riera, A.; Yanez, M.

    1987-01-01

    We apply a new method to calculate widths of two-electron Feshbach resonances, which was described in detail and applied to atomic systems in preceding articles (this issue), to molecular and quasimolecular autoionizing states. For simplicity in the programming effort, we restrict our calculations to the small-R region where one-centered expansions are sufficiently accurate to describe the wave functions. As test cases, positions and widths for the H 2 , He 2 /sup 2+/, HeH + , and LiHe/sup 3+/ resonances of lowest energy are computed for R<0.6 a.u. The advantage of using block-diagonalization techniques to define diabatic resonant states instead of generalizing the Feshbach formalism is pointed out

  20. Simple Methods to Approximate CPC Shape to Preserve Collection Efficiency

    Directory of Open Access Journals (Sweden)

    David Jafrancesco

    2012-01-01

    Full Text Available The compound parabolic concentrator (CPC is the most efficient reflective geometry to collect light to an exit port. Anyway, to allow its actual use in solar plants or photovoltaic concentration systems, a tradeoff between system efficiency and cost reduction, the two key issues for sunlight exploitation, must be found. In this work, we analyze various methods to model an approximated CPC aimed to be simpler and more cost-effective than the ideal one, as well as to preserve the system efficiency. The manufacturing easiness arises from the use of truncated conic surfaces only, which can be realized by cheap machining techniques. We compare different configurations on the basis of their collection efficiency, evaluated by means of nonsequential ray-tracing software. Moreover, due to the fact that some configurations are beam dependent and for a closer approximation of a real case, the input beam is simulated as nonsymmetric, with a nonconstant irradiance on the CPC internal surface.

  1. A simple method for estimation of phosphorous in urine

    International Nuclear Information System (INIS)

    Chaudhary, Seema; Gondane, Sonali; Sawant, Pramilla D.; Rao, D.D.

    2016-01-01

    Following internal contamination of 32 P, it is preferentially eliminated from the body in urine. It is estimated by in-situ precipitation of ammonium molybdo-phosphate (AMP) in urine followed by gross beta counting. The amount of AMP formed in-situ depends on the amount of stable phosphorous (P) present in the urine and hence, it was essential to generate information regarding urinary excretion of stable P. If amount of P excreted is significant then the amount of AMP formed would correspondingly increase leading to absorption of some of the β particles. The present study was taken up for the estimation of daily urinary excretion of P using the phospho-molybdate spectrophotometry method. Few urine samples received from radiation workers were analyzed and based on the observed range of stable P in urine; volume of sample required for 32 P estimation was finalized

  2. A simple method for quantifying jump loads in volleyball athletes.

    Science.gov (United States)

    Charlton, Paula C; Kenneally-Dabrowski, Claire; Sheppard, Jeremy; Spratford, Wayne

    2017-03-01

    Evaluate the validity of a commercially available wearable device, the Vert, for measuring vertical displacement and jump count in volleyball athletes. Propose a potential method of quantifying external load during training and match play within this population. Validation study. The ability of the Vert device to measure vertical displacement in male, junior elite volleyball athletes was assessed against reference standard laboratory motion analysis. The ability of the Vert device to count jumps during training and match-play was assessed via comparison with retrospective video analysis to determine precision and recall. A method of quantifying external load, known as the load index (LdIx) algorithm was proposed using the product of the jump count and average kinetic energy. Correlation between two separate Vert devices and three-dimensional trajectory data were good to excellent for all jump types performed (r=0.83-0.97), with a mean bias of between 3.57-4.28cm. When matched against jumps identified through video analysis, the Vert demonstrated excellent precision (0.995-1.000) evidenced by a low number of false positives. The number of false negatives identified with the Vert was higher resulting in lower recall values (0.814-0.930). The Vert is a commercially available tool that has potential for measuring vertical displacement and jump count in elite junior volleyball athletes without the need for time-consuming analysis and bespoke software. Subsequently, allowing the collected data to better quantify load using the proposed algorithm (LdIx). Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  3. Novel Method of Weighting Cumulative Helmet Impacts Improves Correlation with Brain White Matter Changes After One Football Season of Sub-concussive Head Blows.

    Science.gov (United States)

    Merchant-Borna, Kian; Asselin, Patrick; Narayan, Darren; Abar, Beau; Jones, Courtney M C; Bazarian, Jeffrey J

    2016-12-01

    One football season of sub-concussive head blows has been shown to be associated with subclinical white matter (WM) changes on diffusion tensor imaging (DTI). Prior research analyses of helmet-based impact metrics using mean and peak linear and rotational acceleration showed relatively weak correlations to these WM changes; however, these analyses failed to account for the emerging concept that neuronal vulnerability to successive hits is inversely related to the time between hits (TBH). To develop a novel method for quantifying the cumulative effects of sub-concussive head blows during a single season of collegiate football by weighting helmet-based impact measures for time between helmet impacts. We further aim to compare correlations to changes in DTI after one season of collegiate football using weighted cumulative helmet-based impact measures to correlations using non-weighted cumulative helmet-based impact measures and non-cumulative measures. We performed a secondary analysis of DTI and helmet impact data collected on ten Division III collegiate football players during the 2011 season. All subjects underwent diffusion MR imaging before the start of the football season and within 1 week of the end of the football season. Helmet impacts were recorded at each practice and game using helmet-mounted accelerometers, which computed five helmet-based impact measures for each hit: linear acceleration (LA), rotational acceleration (RA), Gadd Severity Index (GSI), Head Injury Criterion (HIC 15 ), and Head Impact Technology severity profile (HITsp). All helmet-based impact measures were analyzed using five methods of summary: peak and mean (non-cumulative measures), season sum-totals (cumulative unweighted measures), and season sum-totals weighted for time between hits (TBH), the interval of time from hit to post-season DTI assessment (TUA), and both TBH and TUA combined. Summarized helmet-based impact measures were correlated to statistically significant changes in

  4. Thinking Inside the Box: Simple Methods to Evaluate Complex Treatments

    Directory of Open Access Journals (Sweden)

    J. Michael Menke

    2011-10-01

    Full Text Available We risk ignoring cheaper and safer medical treatments because they cannot be patented, lack profit potential, require too much patient-contact time, or do not have scientific results. Novel medical treatments may be difficult to evaluate for a variety of reasons such as patient selection bias, the effect of the package of care, or the lack of identifying the active elements of treatment. Whole Systems Research (WSR is an approach designed to assess the performance of complete packages of clinical management. While the WSR method is compelling, there is no standard procedure for WSR, and its implementation may be intimidating. The truth is that WSR methodological tools are neither new nor complicated. There are two sequential steps, or boxes, that guide WSR methodology: establishing system predictability, followed by an audit of system element effectiveness. We describe the implementation of WSR with a particular attention to threats to validity (Shadish, Cook, & Campbell, 2002; Shadish & Heinsman, 1997. DOI: 10.2458/azu_jmmss.v2i1.12365

  5. Title: a simple method to evaluate linac beam homogeneity

    International Nuclear Information System (INIS)

    Monti, A.F.; Ostinelli, A.; Gelosa, S.; Frigerio, M.

    1995-01-01

    Quality Control (QC) tests in Radiotherapy represent a basic requirement to asses treatment units performance and treatment quality. Since they are generally time consuming, it is worth while to introduce procedures and methods which can be carried on more easily and quickly. Since 1994 in the Radiotherapy Department of S. Anna Hospital, it had been employed a commercially available solid phantom (PRECITRON) with a 10 diodes array, to investigate beam homogeneity (symmetry and flatness). In particular, global symmetry percentage indexes were defined which consider pairs of corresponding points along each axis (x and y) and compare the readings of the respective diodes, following the formula: (I gs =((X d + X -d ) - (Y d + Y -d )((X d + X -d ) + (Y d + Y -d )*200 where X d and X -d are points 8 or 10 cm equally spaced from the beam centre along x axis and the same for Y d and Y -d along y axis. Even if non supporting international protocols requirements as a whole, this parameter gives an important information about beam homogeneity, when only few points of measure are available in a plane, and it can be daily determined, thus fulfilling the aim of lightning immediately each situation capable to compromise treatment accuracy and effectiveness. In this poster we report the results concerning this parameter for a linear accelerator (Varian Clinac 1800), since September 1994 to September 1995

  6. A simple method for particle tracking with coherent synchrotron radiation

    International Nuclear Information System (INIS)

    Borland, M.

    2001-01-01

    Coherent synchrotron radiation (CSR) is of great interest to those designing accelerators as drivers for free-electron lasers (FELs). Although experimental evidence is incomplete, CSR is predicted to have potentially severe effects on the emittance of high-brightness electron beams. The performance of an FEL depends critically on the emittance, current, and energy spread of the beam. Attempts to increase the current through magnetic bunch compression can lead to increased emittance and energy spread due to CSR in the dipoles of such a compressor. The code elegant [1] was used for design and simulation of the bunch compressor [2] for the Low-Energy Undulator Test Line (LEUTL) FEL [3] at the Advanced Photon Source (APS). In order to facilitate this design, a fast algorithm was developed based on the 1-D formalism of Saldin and coworkers [4]. In addition, a plausible method of including CSR effects in drift spaces following the chicane magnets was developed and implemented. The algorithm is fast enough to permit running hundreds of tolerance simulations including CSR for 50 thousand particles. This article describes the details of the implementation and shows results for the APS bunch compressor

  7. siMS Score: Simple Method for Quantifying Metabolic Syndrome.

    Science.gov (United States)

    Soldatovic, Ivan; Vukovic, Rade; Culafic, Djordje; Gajic, Milan; Dimitrijevic-Sreckovic, Vesna

    2016-01-01

    To evaluate siMS score and siMS risk score, novel continuous metabolic syndrome scores as methods for quantification of metabolic status and risk. Developed siMS score was calculated using formula: siMS score = 2*Waist/Height + Gly/5.6 + Tg/1.7 + TAsystolic/130-HDL/1.02 or 1.28 (for male or female subjects, respectively). siMS risk score was calculated using formula: siMS risk score = siMS score * age/45 or 50 (for male or female subjects, respectively) * family history of cardio/cerebro-vascular events (event = 1.2, no event = 1). A sample of 528 obese and non-obese participants was used to validate siMS score and siMS risk score. Scores calculated as sum of z-scores (each component of metabolic syndrome regressed with age and gender) and sum of scores derived from principal component analysis (PCA) were used for evaluation of siMS score. Variants were made by replacing glucose with HOMA in calculations. Framingham score was used for evaluation of siMS risk score. Correlation between siMS score with sum of z-scores and weighted sum of factors of PCA was high (r = 0.866 and r = 0.822, respectively). Correlation between siMS risk score and log transformed Framingham score was medium to high for age groups 18+,30+ and 35+ (0.835, 0.707 and 0.667, respectively). siMS score and siMS risk score showed high correlation with more complex scores. Demonstrated accuracy together with superior simplicity and the ability to evaluate and follow-up individual patients makes siMS and siMS risk scores very convenient for use in clinical practice and research as well.

  8. Method of Factor Extraction and Simple Structure of Data from Diverse Scientific Areas.

    Science.gov (United States)

    Thorndike, Robert M.

    To study the applicability of simple structure logic for factorial data from scientific disciplines outside psychology, four correlation matrices from each of six scientific areas were factor analyzed by five factoring methods. Resulting factor matrices were compared on two objective criteria of simple structure before and after rotation.…

  9. A Simple DTC-SVM method for Matrix Converter Drives Using a Deadbeat Scheme

    DEFF Research Database (Denmark)

    Lee, Kyo-Beum; Blaabjerg, Frede; Lee, Kwang-Won

    2005-01-01

    In this paper, a simple direct torque control (DTC) method for sensorless matrix converter drives is proposed, which is characterized by a simple structure, minimal torque ripple and unity input power factor. Also a good sensorless speed-control performance in the low speed operation is obtained,...

  10. A simple method for the prevention of endometrial autolysis in hysterectomy specimens

    OpenAIRE

    Houghton, J P; Roddy, S; Carroll, S; McCluggage, W G

    2004-01-01

    Aims: Uteri are among the most common surgical pathology specimens. Assessment of the endometrium is often difficult because of pronounced tissue autolysis. This study describes a simple method to prevent endometrial autolysis and aid in interpretation of the endometrium.

  11. A simple method of fitting ill-conditioned polynomials to data

    International Nuclear Information System (INIS)

    Buckler, A.N.; Lawrence, J.

    1979-04-01

    A very simple transformation of the independent variable x is shown to cure the ill-conditioning when some polynomial series are fitted to given Y values. Numerical examples are given to illustrate the power of the method. (author)

  12. Development of the simple evaluation method of the soil biomass by the ATP measurement

    Czech Academy of Sciences Publication Activity Database

    Urashima, Y.; Nakajima, M.; Kaneda, Satoshi; Murakami, T.

    2007-01-01

    Roč. 78, č. 2 (2007), s. 187-190 ISSN 0029-0610 Institutional research plan: CEZ:AV0Z60660521 Keywords : simple evaluation method * soil biomass * ATP measurement Subject RIV: EH - Ecology, Behaviour

  13. [Analysis on the accuracy of simple selection method of Fengshi (GB 31)].

    Science.gov (United States)

    Li, Zhixing; Zhang, Haihua; Li, Suhe

    2015-12-01

    To explore the accuracy of simple selection method of Fengshi (GB 31). Through the study of the ancient and modern data,the analysis and integration of the acupuncture books,the comparison of the locations of Fengshi (GB 31) by doctors from all dynasties and the integration of modern anatomia, the modern simple selection method of Fengshi (GB 31) is definite, which is the same as the traditional way. It is believed that the simple selec tion method is in accord with the human-oriented thought of TCM. Treatment by acupoints should be based on the emerging nature and the individual difference of patients. Also, it is proposed that Fengshi (GB 31) should be located through the integration between the simple method and body surface anatomical mark.

  14. The efficiency of the centroid method compared to a simple average

    DEFF Research Database (Denmark)

    Eskildsen, Jacob Kjær; Kristensen, Kai; Nielsen, Rikke

    Based on empirical data as well as a simulation study this paper gives recommendations with respect to situations wheere a simple avarage of the manifest indicators can be used as a close proxy for the centroid method and when it cannot.......Based on empirical data as well as a simulation study this paper gives recommendations with respect to situations wheere a simple avarage of the manifest indicators can be used as a close proxy for the centroid method and when it cannot....

  15. A simple and secure method to fix laparoscopic trocars in children.

    Science.gov (United States)

    Yip, K F; Tam, P K H; Li, M K W

    2006-04-01

    We introduce a simple method of fixing trocars to the abdominal wall in children. Before anchoring the trocar, a piece of Tegaderm polyurethrane adhesive (3M Healthcare, St. Paul, Minnesota) is attached to the trocar. A silk stitch is anchored to neighboring skin, and then transfixed over the shaft of the trocar through the adhesive. Both inward and outward movement of the trocar can be restrained. This method is simple, fast, secure, and can be applied to trocars of any size.

  16. A simple method for validation and verification of pipettes mounted on automated liquid handlers

    DEFF Research Database (Denmark)

    Stangegaard, Michael; Hansen, Anders Johannes; Frøslev, Tobias Guldberg

     We have implemented a simple method for validation and verification of the performance of pipettes mounted on automated liquid handlers as necessary for laboratories accredited under ISO 17025. An 8-step serial dilution of Orange G was prepared in quadruplicates in a flat bottom 96-well microtit...... available. In conclusion, we have set up a simple solution for the continuous validation of automated liquid handlers used for accredited work. The method is cheap, simple and easy to use for aqueous solutions but requires a spectrophotometer that can read microtiter plates....... We have implemented a simple method for validation and verification of the performance of pipettes mounted on automated liquid handlers as necessary for laboratories accredited under ISO 17025. An 8-step serial dilution of Orange G was prepared in quadruplicates in a flat bottom 96-well microtiter...

  17. The Box-and-Dot Method: A Simple Strategy for Counting Significant Figures

    Science.gov (United States)

    Stephenson, W. Kirk

    2009-01-01

    A visual method for counting significant digits is presented. This easy-to-learn (and easy-to-teach) method, designated the box-and-dot method, uses the device of "boxing" significant figures based on two simple rules, then counting the number of digits in the boxes. (Contains 4 notes.)

  18. Comparing the ISO-recommended and the cumulative data-reduction algorithms in S-on-1 laser damage test by a reverse approach method

    Science.gov (United States)

    Zorila, Alexandru; Stratan, Aurel; Nemes, George

    2018-01-01

    We compare the ISO-recommended (the standard) data-reduction algorithm used to determine the surface laser-induced damage threshold of optical materials by the S-on-1 test with two newly suggested algorithms, both named "cumulative" algorithms/methods, a regular one and a limit-case one, intended to perform in some respects better than the standard one. To avoid additional errors due to real experiments, a simulated test is performed, named the reverse approach. This approach simulates the real damage experiments, by generating artificial test-data of damaged and non-damaged sites, based on an assumed, known damage threshold fluence of the target and on a given probability distribution function to induce the damage. In this work, a database of 12 sets of test-data containing both damaged and non-damaged sites was generated by using four different reverse techniques and by assuming three specific damage probability distribution functions. The same value for the threshold fluence was assumed, and a Gaussian fluence distribution on each irradiated site was considered, as usual for the S-on-1 test. Each of the test-data was independently processed by the standard and by the two cumulative data-reduction algorithms, the resulting fitted probability distributions were compared with the initially assumed probability distribution functions, and the quantities used to compare these algorithms were determined. These quantities characterize the accuracy and the precision in determining the damage threshold and the goodness of fit of the damage probability curves. The results indicate that the accuracy in determining the absolute damage threshold is best for the ISO-recommended method, the precision is best for the limit-case of the cumulative method, and the goodness of fit estimator (adjusted R-squared) is almost the same for all three algorithms.

  19. CROSSER - CUMULATIVE BINOMIAL PROGRAMS

    Science.gov (United States)

    Bowerman, P. N.

    1994-01-01

    The cumulative binomial program, CROSSER, is one of a set of three programs which calculate cumulative binomial probability distributions for arbitrary inputs. The three programs, CROSSER, CUMBIN (NPO-17555), and NEWTONP (NPO-17556), can be used independently of one another. CROSSER can be used by statisticians and users of statistical procedures, test planners, designers, and numerical analysts. The program has been used for reliability/availability calculations. CROSSER calculates the point at which the reliability of a k-out-of-n system equals the common reliability of the n components. It is designed to work well with all integer values 0 < k <= n. To run the program, the user simply runs the executable version and inputs the information requested by the program. The program is not designed to weed out incorrect inputs, so the user must take care to make sure the inputs are correct. Once all input has been entered, the program calculates and lists the result. It also lists the number of iterations of Newton's method required to calculate the answer within the given error. The CROSSER program is written in C. It was developed on an IBM AT with a numeric co-processor using Microsoft C 5.0. Because the source code is written using standard C structures and functions, it should compile correctly with most C compilers. The program format is interactive. It has been implemented under DOS 3.2 and has a memory requirement of 26K. CROSSER was developed in 1988.

  20. Simple equation method for nonlinear partial differential equations and its applications

    Directory of Open Access Journals (Sweden)

    Taher A. Nofal

    2016-04-01

    Full Text Available In this article, we focus on the exact solution of the some nonlinear partial differential equations (NLPDEs such as, Kodomtsev–Petviashvili (KP equation, the (2 + 1-dimensional breaking soliton equation and the modified generalized Vakhnenko equation by using the simple equation method. In the simple equation method the trial condition is the Bernoulli equation or the Riccati equation. It has been shown that the method provides a powerful mathematical tool for solving nonlinear wave equations in mathematical physics and engineering problems.

  1. Radiation transport benchmarks for simple geometries with void regions using the spherical harmonics method

    International Nuclear Information System (INIS)

    Kobayashi, K.

    2009-01-01

    In 2001, an international cooperation on the 3D radiation transport benchmarks for simple geometries with void region was performed under the leadership of E. Sartori of OECD/NEA. There were contributions from eight institutions, where 6 contributions were by the discrete ordinate method and only two were by the spherical harmonics method. The 3D spherical harmonics program FFT3 by the finite Fourier transformation method has been improved for this presentation, and benchmark solutions for the 2D and 3D simple geometries with void region by the FFT2 and FFT3 are given showing fairly good accuracy. (authors)

  2. Simple PVT quantitative method of Kr under high pure N2 condition

    International Nuclear Information System (INIS)

    Li Xuesong; Zhang Zibin; Wei Guanyi; Chen Liyun; Zhai Lihua

    2005-01-01

    A simple PVT quantitative method of Kr in the high pure N 2 was studied. Pressure, volume and temperature of the sample gas were measured by three individual methods to obtain the sum sample with food uncertainty. The ratio of Kr/N 2 could measured by GAM 400 quadrupole mass spectrometer. So the quantity of Kr could be calculated with the two measured data above. This method can be suited for quantitative analysis of other simple composed noble gas sample with high pure carrying gas. (authors)

  3. The Effect of Herrmann Whole Brain Teaching Method on Students' Understanding of Simple Electric Circuits

    Science.gov (United States)

    Bawaneh, Ali Khalid Ali; Nurulazam Md Zain, Ahmad; Salmiza, Saleh

    2011-01-01

    The purpose of this study was to investigate the effect of Herrmann Whole Brain Teaching Method over conventional teaching method on eight graders in their understanding of simple electric circuits in Jordan. Participants (N = 273 students; M = 139, F = 134) were randomly selected from Bani Kenanah region-North of Jordan and randomly assigned to…

  4. Simple methods of aligning four-circle diffractometers with crystal reflections

    Energy Technology Data Exchange (ETDEWEB)

    Mitsui, Y [Tokyo Univ. (Japan). Faculty of Pharmaceutical Sciences

    1979-08-01

    Simple methods of aligning four-circle diffractometers with crystal reflections are devised. They provide the methods to check (1) perpendicularity of chi plane to the incident beam, (2) zero point of 2theta and linearity of focus-chi center-receiving aperture and (3) zero point of chi.

  5. A Simple Method for Dynamic Scheduling in a Heterogeneous Computing System

    OpenAIRE

    Žumer, Viljem; Brest, Janez

    2002-01-01

    A simple method for the dynamic scheduling on a heterogeneous computing system is proposed in this paper. It was implemented to minimize the parallel program execution time. The proposed method decomposes the program workload into computationally homogeneous subtasks, which may be of the different size, depending on the current load of each machine in a heterogeneous computing system.

  6. A simple immunoblotting method after separation of proteins in agarose gel

    DEFF Research Database (Denmark)

    Koch, C; Skjødt, K; Laursen, I

    1985-01-01

    A simple and sensitive method for immunoblotting of proteins after separation in agarose gels is described. It involves transfer of proteins onto nitrocellulose paper simply by diffusion through pressure, a transfer which only takes about 10 min. By this method we have demonstrated the existence ...

  7. 12 CFR 334.25 - Reasonable and simple methods of opting out.

    Science.gov (United States)

    2010-01-01

    ... STATEMENTS OF GENERAL POLICY FAIR CREDIT REPORTING Affiliate Marketing § 334.25 Reasonable and simple methods... or processed at an Internet Web site, if the consumer agrees to the electronic delivery of... opt-out under the Act, and the affiliate marketing opt-out under the Act, by a single method, such as...

  8. A Simple Microsoft Excel Method to Predict Antibiotic Outbreaks and Underutilization.

    Science.gov (United States)

    Miglis, Cristina; Rhodes, Nathaniel J; Avedissian, Sean N; Zembower, Teresa R; Postelnick, Michael; Wunderink, Richard G; Sutton, Sarah H; Scheetz, Marc H

    2017-07-01

    Benchmarking strategies are needed to promote the appropriate use of antibiotics. We have adapted a simple regressive method in Microsoft Excel that is easily implementable and creates predictive indices. This method trends consumption over time and can identify periods of over- and underuse at the hospital level. Infect Control Hosp Epidemiol 2017;38:860-862.

  9. Simple method of obtaining the band strengths in the electronic spectra of diatomic molecules

    International Nuclear Information System (INIS)

    Gowda, L.S.; Balaji, V.N.

    1977-01-01

    It is shown that relative band strengths of diatomic molecules for which the product of Franck-Condon factor and r-centroid is approximately equal to 1 for (0,0) band can be determined by a simple method which is in good agreement with the smoothed array of experimental values. Such values for the Swan bands of the C 2 molecule are compared with the band strengths of the simple method. It is noted that the Swan bands are one of the outstanding features of R- and N-type stars and of the heads of comets

  10. Simple, reliable, and nondestructive method for the measurement of vacuum pressure without specialized equipment.

    Science.gov (United States)

    Yuan, Jin-Peng; Ji, Zhong-Hua; Zhao, Yan-Ting; Chang, Xue-Fang; Xiao, Lian-Tuan; Jia, Suo-Tang

    2013-09-01

    We present a simple, reliable, and nondestructive method for the measurement of vacuum pressure in a magneto-optical trap. The vacuum pressure is verified to be proportional to the collision rate constant between cold atoms and the background gas with a coefficient k, which can be calculated by means of the simple ideal gas law. The rate constant for loss due to collisions with all background gases can be derived from the total collision loss rate by a series of loading curves of cold atoms under different trapping laser intensities. The presented method is also applicable for other cold atomic systems and meets the miniaturization requirement of commercial applications.

  11. Simple and efficient methods for the accurate evaluation of patterning effects in ultrafast photonic switches

    DEFF Research Database (Denmark)

    Xu, Jing; Ding, Yunhong; Peucheret, Christophe

    2011-01-01

    Although patterning effects (PEs) are known to be a limiting factor of ultrafast photonic switches based on semiconductor optical amplifiers (SOAs), a simple approach for their evaluation in numerical simulations and experiments is missing. In this work, we experimentally investigate and verify...... as well as the operation bit rate. Furthermore, a simple and effective method for probing the maximum PEs is demonstrated, which may relieve the computational effort or the experimental difficulties associated with the use of long PRBSs for the simulation or characterization of SOA-based switches. Good...... agrement with conventional PRBS characterization is obtained. The method is suitable for quick and systematic estimation and optimization of the switching performance....

  12. Cumulative Poisson Distribution Program

    Science.gov (United States)

    Bowerman, Paul N.; Scheuer, Ernest M.; Nolty, Robert

    1990-01-01

    Overflow and underflow in sums prevented. Cumulative Poisson Distribution Program, CUMPOIS, one of two computer programs that make calculations involving cumulative Poisson distributions. Both programs, CUMPOIS (NPO-17714) and NEWTPOIS (NPO-17715), used independently of one another. CUMPOIS determines cumulative Poisson distribution, used to evaluate cumulative distribution function (cdf) for gamma distributions with integer shape parameters and cdf for X (sup2) distributions with even degrees of freedom. Used by statisticians and others concerned with probabilities of independent events occurring over specific units of time, area, or volume. Written in C.

  13. Multiscale methods coupling atomistic and continuum mechanics: analysis of a simple case

    OpenAIRE

    Blanc , Xavier; Le Bris , Claude; Legoll , Frédéric

    2007-01-01

    International audience; The description and computation of fine scale localized phenomena arising in a material (during nanoindentation, for instance) is a challenging problem that has given birth to many multiscale methods. In this work, we propose an analysis of a simple one-dimensional method that couples two scales, the atomistic one and the continuum mechanics one. The method includes an adaptive criterion in order to split the computational domain into two subdomains, that are described...

  14. A simple method to adapt time sampling of the analog signal

    International Nuclear Information System (INIS)

    Kalinin, Yu.G.; Martyanov, I.S.; Sadykov, Kh.; Zastrozhnova, N.N.

    2004-01-01

    In this paper we briefly describe the time sampling method, which is adapted to the speed of the signal change. Principally, this method is based on a simple idea--the combination of discrete integration with differentiation of the analog signal. This method can be used in nuclear electronics research into the characteristics of detectors and the shape of the pulse signal, pulse and transitive characteristics of inertial systems of processing of signals, etc

  15. The effects of cumulative practice on mathematics problem solving.

    Science.gov (United States)

    Mayfield, Kristin H; Chase, Philip N

    2002-01-01

    This study compared three different methods of teaching five basic algebra rules to college students. All methods used the same procedures to teach the rules and included four 50-question review sessions interspersed among the training of the individual rules. The differences among methods involved the kinds of practice provided during the four review sessions. Participants who received cumulative practice answered 50 questions covering a mix of the rules learned prior to each review session. Participants who received a simple review answered 50 questions on one previously trained rule. Participants who received extra practice answered 50 extra questions on the rule they had just learned. Tests administered after each review included new questions for applying each rule (application items) and problems that required novel combinations of the rules (problem-solving items). On the final test, the cumulative group outscored the other groups on application and problem-solving items. In addition, the cumulative group solved the problem-solving items significantly faster than the other groups. These results suggest that cumulative practice of component skills is an effective method of training problem solving.

  16. NEWTONP - CUMULATIVE BINOMIAL PROGRAMS

    Science.gov (United States)

    Bowerman, P. N.

    1994-01-01

    The cumulative binomial program, NEWTONP, is one of a set of three programs which calculate cumulative binomial probability distributions for arbitrary inputs. The three programs, NEWTONP, CUMBIN (NPO-17555), and CROSSER (NPO-17557), can be used independently of one another. NEWTONP can be used by statisticians and users of statistical procedures, test planners, designers, and numerical analysts. The program has been used for reliability/availability calculations. NEWTONP calculates the probably p required to yield a given system reliability V for a k-out-of-n system. It can also be used to determine the Clopper-Pearson confidence limits (either one-sided or two-sided) for the parameter p of a Bernoulli distribution. NEWTONP can determine Bayesian probability limits for a proportion (if the beta prior has positive integer parameters). It can determine the percentiles of incomplete beta distributions with positive integer parameters. It can also determine the percentiles of F distributions and the midian plotting positions in probability plotting. NEWTONP is designed to work well with all integer values 0 < k <= n. To run the program, the user simply runs the executable version and inputs the information requested by the program. NEWTONP is not designed to weed out incorrect inputs, so the user must take care to make sure the inputs are correct. Once all input has been entered, the program calculates and lists the result. It also lists the number of iterations of Newton's method required to calculate the answer within the given error. The NEWTONP program is written in C. It was developed on an IBM AT with a numeric co-processor using Microsoft C 5.0. Because the source code is written using standard C structures and functions, it should compile correctly with most C compilers. The program format is interactive. It has been implemented under DOS 3.2 and has a memory requirement of 26K. NEWTONP was developed in 1988.

  17. A new method to study simple shear processing of wheat gluten-starch mixtures

    NARCIS (Netherlands)

    Peighambardoust, S.H.; Goot, A.J. van der; Hamer, R.J.; Boom, R.M.

    2004-01-01

    This article introduces a new method that uses a shearing device to study the effect of simple shear on the overall properties of pasta-like products made from commercial wheat gluten-starch (GS) blends. The shear-processed GS samples had a lower cooking loss (CL) and a higher swelling index (SI)

  18. The simple modelling method for storm- and grey-water quality ...

    African Journals Online (AJOL)

    The simple modelling method for storm- and grey-water quality management applied to Alexandra settlement. ... objectives optimally consist of educational programmes, erosion and sediment control, street sweeping, removal of sanitation system overflows, impervious cover reduction, downspout disconnections, removal of ...

  19. A simple and accurate method for bidimensional position read-out of parallel plate avalanche counters

    International Nuclear Information System (INIS)

    Breskin, A.; Zwang, N.

    1977-01-01

    A simple method for bidimensional position read-out of Parallel Plate Avalanche counters (PPAC) has been developed, using the induced charge technique. An accuracy better than 0.5 mm (FWHM) has been achieved for both coordinates with 5.5. MeV α-particles at gas pressures of 10-40 torr. (author)

  20. Simple method to transfer graphene from metallic catalytic substrates to flexible surfaces without chemical etching

    International Nuclear Information System (INIS)

    Ko, P J; Takahashi, H; Sakai, H; Thu, T V; Okada, H; Sandhu, A; Koide, S

    2013-01-01

    Graphene shows promise for applications in flexible electronics. Here, we describe our procedure to transfer graphene grown on copper substrates by chemical vapor deposition to polydimethylsiloxane (PDMS) and SiO 2 /Si surfaces. The transfer of graphene was achieved by a simple, etching-free method onto flexible PDMS substrates.

  1. 12 CFR 717.25 - Reasonable and simple methods of opting out.

    Science.gov (United States)

    2010-01-01

    ... simple methods for exercising an opt-out right do not include— (i) Requiring the consumer to write his or... out. (a) In general. You must not use eligibility information about a consumer that you receive from an affiliate to make a solicitation to the consumer about your products or services, unless the...

  2. A Simple Method to Determine if a Music Information Retrieval System is a "Horse"

    DEFF Research Database (Denmark)

    Sturm, Bob L.

    2014-01-01

    We propose and demonstrate a simple method to determine if a music information retrieval (MIR) system is using factors irrelevant to the task for which it is designed. This is of critical importance to certain use cases, but cannot be accomplished using standard approaches to evaluation in MIR...

  3. A simple enzymic method for the synthesis of [32P]phosphoenolpyruvate

    International Nuclear Information System (INIS)

    Parra, F.

    1982-01-01

    A rapid and simple enzymic method is described for the synthesis of [ 32 P]phosphoenolpyruvate from [ 32 P]Psub(i), with a reproducible yield of 74%. The final product was shown to be a good substrate for pyruvate kinase (EC 2.7.1.40). (author)

  4. A simple method of fabricating mask-free microfluidic devices for biological analysis.

    KAUST Repository

    Yi, Xin; Kodzius, Rimantas; Gong, Xiuqing; Xiao, Kang; Wen, Weijia

    2010-01-01

    We report a simple, low-cost, rapid, and mask-free method to fabricate two-dimensional (2D) and three-dimensional (3D) microfluidic chip for biological analysis researches. In this fabrication process, a laser system is used to cut through paper

  5. 12 CFR 571.25 - Reasonable and simple methods of opting out.

    Science.gov (United States)

    2010-01-01

    ... CREDIT REPORTING Affiliate Marketing § 571.25 Reasonable and simple methods of opting out. (a) In general... out, such as a form that can be electronically mailed or processed at an Internet Web site, if the... (15 U.S.C. 6801 et seq.), the affiliate sharing opt-out under the Act, and the affiliate marketing opt...

  6. 16 CFR 680.25 - Reasonable and simple methods of opting out.

    Science.gov (United States)

    2010-01-01

    ... AFFILIATE MARKETING § 680.25 Reasonable and simple methods of opting out. (a) In general. You must not use... a form that can be electronically mailed or processed at an Internet Web site, if the consumer..., 15 U.S.C. 6801 et seq., the affiliate sharing opt-out under the Act, and the affiliate marketing opt...

  7. A simple red-ox titrimetric method for the evaluation of photo ...

    Indian Academy of Sciences (India)

    Unknown

    tal conditions in a relatively short duration in R&D labora- tories having basic analytical facilities. The method suggested here could also be adopted to study the photo- catalytic activity of other transition metal oxide based catalysts. For establishing this technique, we have moni- tored a simple one-electron transfer red-ox ...

  8. A simple method of chaos control for a class of chaotic discrete-time systems

    International Nuclear Information System (INIS)

    Jiang Guoping; Zheng Weixing

    2005-01-01

    In this paper, a simple method is proposed for chaos control for a class of discrete-time chaotic systems. The proposed method is built upon the state feedback control and the characteristic of ergodicity of chaos. The feedback gain matrix of the controller is designed using a simple criterion, so that control parameters can be selected via the pole placement technique of linear control theory. The new controller has a feature that it only uses the state variable for control and does not require the target equilibrium point in the feedback path. Moreover, the proposed control method cannot only overcome the so-called 'odd eigenvalues number limitation' of delayed feedback control, but also control the chaotic systems to the specified equilibrium points. The effectiveness of the proposed method is demonstrated by a two-dimensional discrete-time chaotic system

  9. A simple method for one-loop renormalization in curved space-time

    Energy Technology Data Exchange (ETDEWEB)

    Markkanen, Tommi [Helsinki Institute of Physics and Department of Physics, P.O. Box 64, FI-00014, University of Helsinki (Finland); Tranberg, Anders, E-mail: tommi.markkanen@helsinki.fi, E-mail: anders.tranberg@uis.no [Niels Bohr International Academy and Discovery Center, Niels Bohr Institute, Blegdamsvej 17, 2100 Copenhagen (Denmark)

    2013-08-01

    We present a simple method for deriving the renormalization counterterms from the components of the energy-momentum tensor in curved space-time. This method allows control over the finite parts of the counterterms and provides explicit expressions for each term separately. As an example, the method is used for the self-interacting scalar field in a Friedmann-Robertson-Walker metric in the adiabatic approximation, where we calculate the renormalized equation of motion for the field and the renormalized components of the energy-momentum tensor to fourth adiabatic order while including interactions to one-loop order. Within this formalism the trace anomaly, including contributions from interactions, is shown to have a simple derivation. We compare our results to those obtained by two standard methods, finding agreement with the Schwinger-DeWitt expansion but disagreement with adiabatic subtractions for interacting theories.

  10. Fill rate estimation in periodic review policies with lost sales using simple methods

    Energy Technology Data Exchange (ETDEWEB)

    Cardós, M.; Guijarro Tarradellas, E.; Babiloni Griñón, E.

    2016-07-01

    Purpose: The exact estimation of the fill rate in the lost sales case is complex and time consuming. However, simple and suitable methods are needed for its estimation so that inventory managers could use them. Design/methodology/approach: Instead of trying to compute the fill rate in one step, this paper focuses first on estimating the probabilities of different on-hand stock levels so that the fill rate is computed later. Findings: As a result, the performance of a novel proposed method overcomes the other methods and is relatively simple to compute. Originality/value: Existing methods for estimating stock levels are examined, new procedures are proposed and their performance is assessed.

  11. An aggregate method to calibrate the reference point of cumulative prospect theory-based route choice model for urban transit network

    Science.gov (United States)

    Zhang, Yufeng; Long, Man; Luo, Sida; Bao, Yu; Shen, Hanxia

    2015-12-01

    Transit route choice model is the key technology of public transit systems planning and management. Traditional route choice models are mostly based on expected utility theory which has an evident shortcoming that it cannot accurately portray travelers' subjective route choice behavior for their risk preferences are not taken into consideration. Cumulative prospect theory (CPT), a brand new theory, can be used to describe travelers' decision-making process under the condition of uncertainty of transit supply and risk preferences of multi-type travelers. The method to calibrate the reference point, a key parameter to CPT-based transit route choice model, determines the precision of the model to a great extent. In this paper, a new method is put forward to obtain the value of reference point which combines theoretical calculation and field investigation results. Comparing the proposed method with traditional method, it shows that the new method can promote the quality of CPT-based model by improving the accuracy in simulating travelers' route choice behaviors based on transit trip investigation from Nanjing City, China. The proposed method is of great significance to logical transit planning and management, and to some extent makes up the defect that obtaining the reference point is solely based on qualitative analysis.

  12. A simple method for plasma total vitamin C analysis suitable for routine clinical laboratory use

    OpenAIRE

    Robitaille, Line; Hoffer, L. John

    2016-01-01

    Background In-hospital hypovitaminosis C is highly prevalent but almost completely unrecognized. Medical awareness of this potentially important disorder is hindered by the inability of most hospital laboratories to determine plasma vitamin C concentrations. The availability of a simple, reliable method for analyzing plasma vitamin C could increase opportunities for routine plasma vitamin C analysis in clinical medicine. Methods Plasma vitamin C can be analyzed by high performance liquid chro...

  13. A simple method to evaluate the composition of tissue-equivalent phantom materials

    International Nuclear Information System (INIS)

    Geske, G.

    1977-01-01

    A description is given of a method to calculate the composition of phantom materials with given density and radiation-physical parameters mixed of components, of which are known their chemical composition and their effective specific volumes. By an example of a simple composition with three components the method is illustrated. The results of this example and some experimental details that must be considered are discussed. (orig.) [de

  14. A simple optical method for measuring the vibration amplitude of a speaker

    OpenAIRE

    UEDA, Masahiro; YAMAGUCHI, Toshihiko; KAKIUCHI, Hiroki; SUGA, Hiroshi

    1999-01-01

    A simple optical method has been proposed for measuring the vibration amplitude of a speaker vibrating with a frequency of approximately 10 kHz. The method is based on a multiple reflection between a vibrating speaker plane and a mirror parallel to that speaker plane. The multiple reflection can magnify a dispersion of the laser beam caused by the vibration, and easily make a measurement of the amplitude. The measuring sensitivity ranges between sub-microns and 1 mm. A preliminary experim...

  15. Simple and effective method for nuclear tellurium isomers separation from antimony cyclotron targets

    International Nuclear Information System (INIS)

    Bondarevskij, S.I.; Eremin, V.V.

    1999-01-01

    Simple and effective method of generation of tellurium nuclear isomers from irradiated on cyclotron metallic antimony is suggested. Basically this method consists in consideration of the big difference in volatilities of metallic forms of antimony, tin and tellurium. Heating of the tin-antimony alloy at 1200 K permits to separate about 90 % of produced quantity of 121m Te and 123m Te (in this case impurity of antimony radionuclides is not more than 1 % on activity) [ru

  16. A simple and fast method for extraction and quantification of cryptophyte phycoerythrin

    OpenAIRE

    Thoisen, Christina; Hansen, Benni Winding; Nielsen, S?ren Laurentius

    2017-01-01

    The microalgal pigment phycoerythrin (PE) is of commercial interest as natural colorant in food and cosmetics, as well as fluoroprobes for laboratory analysis. Several methods for extraction and quantification of PE are available but they comprise typically various extraction buffers, repetitive freeze-thaw cycles and liquid nitrogen, making extraction procedures more complicated. A simple method for extraction of PE from cryptophytes is described using standard laboratory materials and equip...

  17. A simple method to downscale daily wind statistics to hourly wind data

    OpenAIRE

    Guo, Zhongling

    2013-01-01

    Wind is the principal driver in the wind erosion models. The hourly wind speed data were generally required for precisely wind erosion modeling. In this study, a simple method to generate hourly wind speed data from daily wind statistics (daily average and maximum wind speeds together or daily average wind speed only) was established. A typical windy location with 3285 days (9 years) measured hourly wind speed data were used to validate the downscaling method. The results showed that the over...

  18. Simulation Opportunity Index, A Simple and Effective Method to Boost the Hydrocarbon Recovery

    KAUST Repository

    Saputra, Wardana

    2016-01-01

    This paper describes how the SOI software helps as a simple, fast, and accurate way to obtain the higher hydrocarbon production than that of trial-error method and previous studies in two different fields located in offshore Indonesia. On one hand, the proposed method could save money by minimizing the required number of wells. On the other hand, it could maximize profit by maximizing recovery.

  19. A simple and efficient method for isolating small RNAs from different plant species

    Directory of Open Access Journals (Sweden)

    de Folter Stefan

    2011-02-01

    Full Text Available Abstract Background Small RNAs emerged over the last decade as key regulators in diverse biological processes in eukaryotic organisms. To identify and study small RNAs, good and efficient protocols are necessary to isolate them, which sometimes may be challenging due to the composition of specific tissues of certain plant species. Here we describe a simple and efficient method to isolate small RNAs from different plant species. Results We developed a simple and efficient method to isolate small RNAs from different plant species by first comparing different total RNA extraction protocols, followed by streamlining the best one, finally resulting in a small RNA extraction method that has no need of first total RNA extraction and is not based on the commercially available TRIzol® Reagent or columns. This small RNA extraction method not only works well for plant tissues with high polysaccharide content, like cactus, agave, banana, and tomato, but also for plant species like Arabidopsis or tobacco. Furthermore, the obtained small RNA samples were successfully used in northern blot assays. Conclusion Here we provide a simple and efficient method to isolate small RNAs from different plant species, such as cactus, agave, banana, tomato, Arabidopsis, and tobacco, and the small RNAs from this simplified and low cost method is suitable for downstream handling like northern blot assays.

  20. A Simple and Reliable Method of Design for Standalone Photovoltaic Systems

    Science.gov (United States)

    Srinivasarao, Mantri; Sudha, K. Rama; Bhanu, C. V. K.

    2017-06-01

    Standalone photovoltaic (SAPV) systems are seen as a promoting method of electrifying areas of developing world that lack power grid infrastructure. Proliferations of these systems require a design procedure that is simple, reliable and exhibit good performance over its life time. The proposed methodology uses simple empirical formulae and easily available parameters to design SAPV systems, that is, array size with energy storage. After arriving at the different array size (area), performance curves are obtained for optimal design of SAPV system with high amount of reliability in terms of autonomy at a specified value of loss of load probability (LOLP). Based on the array to load ratio (ALR) and levelized energy cost (LEC) through life cycle cost (LCC) analysis, it is shown that the proposed methodology gives better performance, requires simple data and is more reliable when compared with conventional design using monthly average daily load and insolation.

  1. A simple method for validation and verification of pipettes mounted on automated liquid handlers

    DEFF Research Database (Denmark)

    Stangegaard, Michael; Hansen, Anders Johannes; Frøslev, Tobias G

    2011-01-01

    We have implemented a simple, inexpensive, and fast procedure for validation and verification of the performance of pipettes mounted on automated liquid handlers (ALHs) as necessary for laboratories accredited under ISO 17025. A six- or seven-step serial dilution of OrangeG was prepared in quadru......We have implemented a simple, inexpensive, and fast procedure for validation and verification of the performance of pipettes mounted on automated liquid handlers (ALHs) as necessary for laboratories accredited under ISO 17025. A six- or seven-step serial dilution of OrangeG was prepared...... are freely available. In conclusion, we have set up a simple, inexpensive, and fast solution for the continuous validation of ALHs used for accredited work according to the ISO 17025 standard. The method is easy to use for aqueous solutions but requires a spectrophotometer that can read microtiter plates....

  2. A simple and fast method for extraction and quantification of cryptophyte phycoerythrin.

    Science.gov (United States)

    Thoisen, Christina; Hansen, Benni Winding; Nielsen, Søren Laurentius

    2017-01-01

    The microalgal pigment phycoerythrin (PE) is of commercial interest as natural colorant in food and cosmetics, as well as fluoroprobes for laboratory analysis. Several methods for extraction and quantification of PE are available but they comprise typically various extraction buffers, repetitive freeze-thaw cycles and liquid nitrogen, making extraction procedures more complicated. A simple method for extraction of PE from cryptophytes is described using standard laboratory materials and equipment. The cryptophyte cells on the filters were disrupted at -80 °C and added phosphate buffer for extraction at 4 °C followed by absorbance measurement. The cryptophyte Rhodomonas salina was used as a model organism. •Simple method for extraction and quantification of phycoerythrin from cryptophytes.•Minimal usage of equipment and chemicals, and low labor costs.•Applicable for industrial and biological purposes.

  3. A simple and fast method for extraction and quantification of cryptophyte phycoerythrin

    DEFF Research Database (Denmark)

    Thoisen, Christina Vinum; Hansen, Benni Winding; Nielsen, Søren Laurentius

    2017-01-01

    The microalgal pigment phycoerythrin (PE) is of commercial interest as natural colorant in food and cosmetics, as well as fluoroprobes for laboratory analysis. Several methods for extraction and quantification of PE are available but they comprise typically various extraction buffers, repetitive...... freeze-thaw cycles and liquid nitrogen, making extraction procedures more complicated. A simple method for extraction of PE from cryptophytes is described using standard laboratory materials and equipment. Filters with the cryptophyte were frozen (−80 °C) and added phosphate buffer for extraction at 4 °C...... followed by absorbance measurement. The cryptophyte Rhodomonas salina was used as a model organism. •Simple method for extraction and quantification of phycoerythrin from cryptophytes. •Minimal usage of equipment and chemicals, and low labor costs. •Applicable for industrial and biological purposes....

  4. Validity of a Simple Method for Measuring Force-Velocity-Power Profile in Countermovement Jump.

    Science.gov (United States)

    Jiménez-Reyes, Pedro; Samozino, Pierre; Pareja-Blanco, Fernando; Conceição, Filipe; Cuadrado-Peñafiel, Víctor; González-Badillo, Juan José; Morin, Jean-Benoît

    2017-01-01

    To analyze the reliability and validity of a simple computation method to evaluate force (F), velocity (v), and power (P) output during a countermovement jump (CMJ) suitable for use in field conditions and to verify the validity of this computation method to compute the CMJ force-velocity (F-v) profile (including unloaded and loaded jumps) in trained athletes. Sixteen high-level male sprinters and jumpers performed maximal CMJs under 6 different load conditions (0-87 kg). A force plate sampling at 1000 Hz was used to record vertical ground-reaction force and derive vertical-displacement data during CMJ trials. For each condition, mean F, v, and P of the push-off phase were determined from both force-plate data (reference method) and simple computation measures based on body mass, jump height (from flight time), and push-off distance and used to establish the linear F-v relationship for each individual. Mean absolute bias values were 0.9% (± 1.6%), 4.7% (± 6.2%), 3.7% (± 4.8%), and 5% (± 6.8%) for F, v, P, and slope of the F-v relationship (S Fv ), respectively. Both methods showed high correlations for F-v-profile-related variables (r = .985-.991). Finally, all variables computed from the simple method showed high reliability, with ICC >.980 and CV push-off distance, and jump height are known.

  5. Simple measurement of 14C in the environment using gel suspension method

    International Nuclear Information System (INIS)

    Wakabayashi, Genichiro; Oura, Hirotaka; Nagao, Kenjiro; Okai, Tomio; Matoba, Masaru; Kakiuchi, Hideki; Momoshima, Noriyuki; Kawamura, Hidehisa

    1999-01-01

    A gel suspension method using N-lauroyl-L-glutamic-α, γ-dibutylamide as gelling agent and calcium carbonate as sample was studied and it was proved a more simple measurement method of 14 C in environment than the ordinary method. 100, 20 and 7 ml of sample could introduce 3.6, 0.72 and 0.252 g of carbon, respectively. When 100 ml and 20 ml of vial introduced the maximum carbon, the lower limit of detection was about 0.3 dpm/g-C and 0.5 dpm/g-C, respectively. These values showed that this method was able to determine 14 C in the environment. The value of sample has been constant for two years or more. This fact indicated the sample prepared by this method was good for repeat measurement and long-term storage. Many samples prepared by the same calcium carbonate showed almost same values. The concentrations of 14 C in the growth rings of a tree and in rice in the environment were determined and the results agreed with the values in the references. From these above results, this method is more simple measurement method of 14 C in the environment than the ordinary method and can apply to determine 14 C in and around the nuclear installation. (S.Y.)

  6. A simple method for HPLC retention time prediction: linear calibration using two reference substances.

    Science.gov (United States)

    Sun, Lei; Jin, Hong-Yu; Tian, Run-Tao; Wang, Ming-Juan; Liu, Li-Na; Ye, Liu-Ping; Zuo, Tian-Tian; Ma, Shuang-Cheng

    2017-01-01

    Analysis of related substances in pharmaceutical chemicals and multi-components in traditional Chinese medicines needs bulk of reference substances to identify the chromatographic peaks accurately. But the reference substances are costly. Thus, the relative retention (RR) method has been widely adopted in pharmacopoeias and literatures for characterizing HPLC behaviors of those reference substances unavailable. The problem is it is difficult to reproduce the RR on different columns due to the error between measured retention time (t R ) and predicted t R in some cases. Therefore, it is useful to develop an alternative and simple method for prediction of t R accurately. In the present study, based on the thermodynamic theory of HPLC, a method named linear calibration using two reference substances (LCTRS) was proposed. The method includes three steps, procedure of two points prediction, procedure of validation by multiple points regression and sequential matching. The t R of compounds on a HPLC column can be calculated by standard retention time and linear relationship. The method was validated in two medicines on 30 columns. It was demonstrated that, LCTRS method is simple, but more accurate and more robust on different HPLC columns than RR method. Hence quality standards using LCTRS method are easy to reproduce in different laboratories with lower cost of reference substances.

  7. Divergent Cumulative Cultural Evolution

    OpenAIRE

    Marriott, Chris; Chebib, Jobran

    2016-01-01

    Divergent cumulative cultural evolution occurs when the cultural evolutionary trajectory diverges from the biological evolutionary trajectory. We consider the conditions under which divergent cumulative cultural evolution can occur. We hypothesize that two conditions are necessary. First that genetic and cultural information are stored separately in the agent. Second cultural information must be transferred horizontally between agents of different generations. We implement a model with these ...

  8. Exploring simple assessment methods for lighting quality with architecture and design students

    DEFF Research Database (Denmark)

    Madsen, Merete

    2006-01-01

    that cannot be assessed by simple equations or rules-of-thumb. Balancing the many an often contradictory aspects of energy efficiency and high quality lighting design is a complex undertaking not just for students. The work described in this paper is one result of an academic staff exchange between...... the Schools of Architecture in Copenhagen and Victoria University of Wellington (New Zealand). The authors explore two approaches to teaching students simple assessment methods that can contribute to making more informed decisions about the luminous environment and its quality. One approach deals...... with the assessment of luminance ratios in relation to computer work and presents in that context some results from an experiment undertaken to introduce the concept of luminance ratios and preferred luminance ranges to architeture students. In the other approach a Danish method for assissing the luminance...

  9. Development of Test Method for Simple Shear and Prediction of Hardening Behavior Considering the Branchings Effect

    International Nuclear Information System (INIS)

    Kim, Dongwook; Bang, Sungsik; Kim, Minsoo; Lee, Hyungyil; Kim, Naksoo

    2013-01-01

    In this study we establish a process to predict hardening behavior considering the Branchings effect for zircaloy-4 sheets. When a metal is compressed after tension in forming, the yield strength decreases. For this reason, the Branchings effect should be considered in FE simulations of spring-back. We suggested a suitable specimen size and a method for determining the optimum tightening torque for simple shear tests. Shear stress-strain curves are obtained for five materials. We developed a method to convert the shear load-displacement curve to the effective stress-strain curve with Fea. We simulated the simple shear forward/reverse test using the combined isotropic/kinematic hardening model. We also investigated the change of the load-displacement curve by varying the hardening coefficients. We determined the hardening coefficients so that they follow the hardening behavior of zircaloy-4 in experiments

  10. Development of Test Method for Simple Shear and Prediction of Hardening Behavior Considering the Branchings Effect

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dongwook; Bang, Sungsik; Kim, Minsoo; Lee, Hyungyil; Kim, Naksoo [Sogang Univ., Seoul (Korea, Republic of)

    2013-10-15

    In this study we establish a process to predict hardening behavior considering the Branchings effect for zircaloy-4 sheets. When a metal is compressed after tension in forming, the yield strength decreases. For this reason, the Branchings effect should be considered in FE simulations of spring-back. We suggested a suitable specimen size and a method for determining the optimum tightening torque for simple shear tests. Shear stress-strain curves are obtained for five materials. We developed a method to convert the shear load-displacement curve to the effective stress-strain curve with Fea. We simulated the simple shear forward/reverse test using the combined isotropic/kinematic hardening model. We also investigated the change of the load-displacement curve by varying the hardening coefficients. We determined the hardening coefficients so that they follow the hardening behavior of zircaloy-4 in experiments.

  11. A simple and accurate onset detection method for a measured bell-shaped speed profile

    Directory of Open Access Journals (Sweden)

    Lior Botzer

    2009-06-01

    Full Text Available Motor control neuroscientists measure limb trajectories and extract the onset of the movement for a variety of purposes. Such trajectories are often aligned relative to the onset of individual movement before the features of that movement are extracted and their properties are inspected. Onset detection is performed either manually or automatically, typically by selecting a velocity threshold. Here, we present a simple onset detection algorithm that is more accurate than the conventional velocity threshold technique. The proposed method is based on a simple regression and follows the minimum acceleration with constraints model, in which the initial phase of the bell-shaped movement is modeled by a cubic power of the time. We demonstrate the performance of the suggested method and compare it to the velocity threshold technique and to manual onset detection by a group of motor control experts. The database for this comparison consists of simulated minimum jerk trajectories and recorded reaching movements.

  12. A simple method for generation of back-ground-free gamma-ray spectra

    International Nuclear Information System (INIS)

    Kawarasaki, Y.

    1976-01-01

    A simple and versatile method of generating background-free γ-ray spectra is presented. This method is equivalent to the generation of a continuous background baseline over the entire energy range of spectra corresponding to the original ones obtained with a Ge(Li) detector. These background curves can not be generally expressed in a single and simple analytic form nor in the form of a power series. These background-free spectra thus obtained make it feasible to assign many tiny peaks at the stage of visual inspection of the spectra, which is difficult to do with the original ones. The automatic peak-finding and peak area calculation procedures are both applicable to these background-free spectra. Examples of the application are illustrated. The effect of the peak-shape distortion is also discussed. (Auth.)

  13. A simple method for deriving functional MSCs and applied for osteogenesis in 3D scaffolds

    DEFF Research Database (Denmark)

    Zou, Lijin; Luo, Yonglun; Chen, Muwan

    2013-01-01

    We describe a simple method for bone engineering using biodegradable scaffolds with mesenchymal stem cells derived from human induced-pluripotent stem cells (hiPS-MSCs). The hiPS-MSCs expressed mesenchymal markers (CD90, CD73, and CD105), possessed multipotency characterized by tri......-lineages differentiation: osteogenic, adipogenic, and chondrogenic, and lost pluripotency - as seen with the loss of markers OCT3/4 and TRA-1-81 - and tumorigenicity. However, these iPS-MSCs are still positive for marker NANOG. We further explored the osteogenic potential of the hiPS-MSCs in synthetic polymer......, our results suggest the iPS-MSCs derived by this simple method retain fully osteogenic function and provide a new solution towards personalized orthopedic therapy in the future....

  14. Lowest-order constrained variational method for simple many-fermion systems

    International Nuclear Information System (INIS)

    Alexandrov, I.; Moszkowski, S.A.; Wong, C.W.

    1975-01-01

    The authors study the potential energy of many-fermion systems calculated by the lowest-order constrained variational (LOCV) method of Pandharipande. Two simple two-body interactions are used. For a simple hard-core potential in a dilute Fermi gas, they find that the Huang-Yang exclusion correction can be used to determine a healing distance. The result is close to the older Pandharipande prescription for the healing distance. For a hard core plus attractive exponential potential, the LOCV result agrees closely with the lowest-order separation method of Moszkowski and Scott. They find that the LOCV result has a shallow minimum as a function of the healing distance at the Moszkowski-Scott separation distance. The significance of the absence of a Brueckner dispersion correction in the LOCV result is discussed. (Auth.)

  15. Double-lock technique: a simple method to secure abdominal wall closure

    International Nuclear Information System (INIS)

    Jategaonkar, P.A.; Yadav, S.P.

    2013-01-01

    Secure closure of a laparotomy incision remains an important aspect of any abdominal operation with the aim to avoid the postoperative morbidity and hasten the patient's recovery. Depending on the operator's preference and experience, it may be done by the continuous or the interrupted methods either using a non-absorbable or delayed-absorbable suture. We describe a simple, secure and quick technique of abdominal wall closure which involves continuous suture inter-locked doubly after every third bite. This simple and easy to use mass closure technique can be easily mastered by any member of the surgical team and does not need any assistant. It amalgamates the advantages of both, the continuous and the interrupted methods of closures. To our knowledge, such a technique has not been reported in the literature. (author)

  16. A Simple Method to Measure Nematodes' Propulsive Thrust and the Nematode Ratchet.

    Science.gov (United States)

    Bau, Haim; Yuan, Jinzhou; Raizen, David

    2015-11-01

    Since the propulsive thrust of micro organisms provides a more sensitive indicator of the animal's health and response to drugs than motility, a simple, high throughput, direct measurement of the thrust is desired. Taking advantage of the nematode C. elegans being heavier than water, we devised a simple method to determine the propulsive thrust of the animals by monitoring their velocity when swimming along an inclined plane. We find that the swimming velocity is a linear function of the sin of the inclination angle. This method allows us to determine, among other things, the animas' propulsive thrust as a function of genotype, drugs, and age. Furthermore, taking advantage of the animals' inability to swim over a stiff incline, we constructed a sawteeth ratchet-like track that restricts the animals to swim in a predetermined direction. This research was supported, in part, by NIH NIA Grant 5R03AG042690-02.

  17. A statistical method for evaluation of the experimental phase equilibrium data of simple clathrate hydrates

    DEFF Research Database (Denmark)

    Eslamimanesh, Ali; Gharagheizi, Farhad; Mohammadi, Amir H.

    2012-01-01

    We, herein, present a statistical method for diagnostics of the outliers in phase equilibrium data (dissociation data) of simple clathrate hydrates. The applied algorithm is performed on the basis of the Leverage mathematical approach, in which the statistical Hat matrix, Williams Plot, and the r......We, herein, present a statistical method for diagnostics of the outliers in phase equilibrium data (dissociation data) of simple clathrate hydrates. The applied algorithm is performed on the basis of the Leverage mathematical approach, in which the statistical Hat matrix, Williams Plot...... in exponential form is used to represent/predict the hydrate dissociation pressures for three-phase equilibrium conditions (liquid water/ice–vapor-hydrate). The investigated hydrate formers are methane, ethane, propane, carbon dioxide, nitrogen, and hydrogen sulfide. It is interpreted from the obtained results...

  18. A simple method for labelling proteins with 211At via diazotized aromatic diamine

    International Nuclear Information System (INIS)

    Wunderlich, G.; Franke, W.-G.; Fischer, S.; Dreyer, R.

    1987-01-01

    A simple and rapid method for labelling proteins with 211 At by means of a 1,4-diaminobenzene link is described. This link is transformed into the diazonium salt and subsequently reactions of both 211 At and proteins with the diazonium salt take place simultaneously. For possibly high yields of astatized protein an appropriate temperature of 273 K was found. The results demonstrate the difference between the reaction mechanisms of iodine and astatine with proteins. (author)

  19. A simple method to take urethral sutures for neobladder reconstruction and radical prostatectomy

    Directory of Open Access Journals (Sweden)

    B Satheesan

    2007-01-01

    Full Text Available For the reconstruction of urethra-vesical anastamosis after radical prostatectomy and for neobladder reconstruction, taking adequate sutures to include the urethral mucosa is vital. Due to the retraction of the urethra and unfriendly pelvis, the process of taking satisfactory urethral sutures may be laborious. Here, we describe a simple method by which we could overcome similar technical problems during surgery using Foley catheter as the guide for the suture.

  20. A Simple Method to Estimate Large Fixed Effects Models Applied to Wage Determinants and Matching

    OpenAIRE

    Mittag, Nikolas

    2016-01-01

    Models with high dimensional sets of fixed effects are frequently used to examine, among others, linked employer-employee data, student outcomes and migration. Estimating these models is computationally difficult, so simplifying assumptions that are likely to cause bias are often invoked to make computation feasible and specification tests are rarely conducted. I present a simple method to estimate large two-way fixed effects (TWFE) and worker-firm match effect models without additional assum...

  1. A simple, rapid and inexpensive screening method for the identification of Pythium insidiosum.

    Science.gov (United States)

    Tondolo, Juliana Simoni Moraes; Loreto, Erico Silva; Denardi, Laura Bedin; Mario, Débora Alves Nunes; Alves, Sydney Hartz; Santurio, Janio Morais

    2013-04-01

    Growth of Pythium insidiosum mycelia around minocycline disks (30μg) did not occur within 7days of incubation at 35°C when the isolates were grown on Sabouraud, corn meal, Muller-Hinton or RPMI agar. This technique offers a simple and rapid method for the differentiation of P. insidiosum from true filamentous fungi. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. A Simple Method for Determination of Critical Swimming Velocity in Swimming Flume

    OpenAIRE

    高橋, 繁浩; 若吉, 浩二; Shigehiro, TAKAHASHI; Kohji, WAKAYOSHI; 中京大学; 奈良教育大学教育学部

    2001-01-01

    The purpose of this study was to investigate a simple method for determination of critical swimming velocity (Vcri). Vcri is defined by Wakayoshi et al. (1992) as the swimming speed which could theoretically be maintained forever without exhaustion, and is expressed as the slope of a regression line between swimming distance (D) and swimming time (T) obtained at various swimming speeds. To determine Vcri, 20 well-trained swimmers were measured at several swimming speeds ranging from 1.25 m/se...

  3. Simple analytical methods for computing the gravity-wave contribution to the cosmic background radiation anisotropy

    International Nuclear Information System (INIS)

    Wang, Y.

    1996-01-01

    We present two simple analytical methods for computing the gravity-wave contribution to the cosmic background radiation (CBR) anisotropy in inflationary models; one method uses a time-dependent transfer function, the other methods uses an approximate gravity-mode function which is a simple combination of the lowest order spherical Bessel functions. We compare the CBR anisotropy tensor multipole spectrum computed using our methods with the previous result of the highly accurate numerical method, the open-quote open-quote Boltzmann close-quote close-quote method. Our time-dependent transfer function is more accurate than the time-independent transfer function found by Turner, White, and Lindsey; however, we find that the transfer function method is only good for l approx-lt 120. Using our approximate gravity-wave mode function, we obtain much better accuracy; the tensor multipole spectrum we find differs by less than 2% for l approx-lt 50, less than 10% for l approx-lt 120, and less than 20% for l≤300 from the open-quote open-quote Boltzmann close-quote close-quote result. Our approximate graviton mode function should be quite useful in studying tensor perturbations from inflationary models. copyright 1996 The American Physical Society

  4. A Study of Simple α Source Preparation Using a Micro-coprecipitation Method

    International Nuclear Information System (INIS)

    Lee, Myung Ho; Park, Taehong; Song, Byung Chul; Park, Jong Ho; Song, Kyuseok

    2012-01-01

    This study presents a rapid and simple α source preparation method for a radioactive waste sample. The recovery of 239 Pu, 232 U and 243 Am using a micro-coprecipitation method was over 95%. The α-peak resolution of Pu and Am isotopes through the micro-coprecipitation method is enough to discriminate the Pu and Am isotopes from other Pu and Am isotopes. The determination of the Pu and Am isotopes using the micro-coprecipitation method was applied to the radioactive waste sample, so that the activity concentrations of the Pu and Am isotopes using the micro-coprecipitation method in the radioactive waste sample were similar to those using the electrodeposition method

  5. A simple two-step method to fabricate highly transparent ITO/polymer nanocomposite films

    International Nuclear Information System (INIS)

    Liu, Haitao; Zeng, Xiaofei; Kong, Xiangrong; Bian, Shuguang; Chen, Jianfeng

    2012-01-01

    Highlights: ► A simple two-step method without further surface modification step was employed. ► ITO nanoparticles were easily to be uniformly dispersed in polymer matrix. ► ITO/polymer nanocomposite film had high transparency and UV/IR blocking properties. - Abstract: Transparent functional indium tin oxide (ITO)/polymer nanocomposite films were fabricated via a simple approach with two steps. Firstly, the functional monodisperse ITO nanoparticles were synthesized via a facile nonaqueous solvothermal method using bifunctional chemical agent (N-methyl-pyrrolidone, NMP) as the reaction solvent and surface modifier. Secondly, the ITO/acrylics polyurethane (PUA) nanocomposite films were fabricated by a simple sol-solution mixing method without any further surface modification step as often employed traditionally. Flower-like ITO nanoclusters with about 45 nm in diameter were mono-dispersed in ethyl acetate and each nanocluster was assembled by nearly spherical nanoparticles with primary size of 7–9 nm in diameter. The ITO nanoclusters exhibited an excellent dispersibility in polymer matrix of PUA, remaining their original size without any further agglomeration. When the loading content of ITO nanoclusters reached to 5 wt%, the transparent functional nanocomposite film featured a high transparency more than 85% in the visible light region (at 550 nm), meanwhile cutting off near-infrared radiation about 50% at 1500 nm and blocking UV ray about 45% at 350 nm. It could be potential for transparent functional coating materials applications.

  6. A simple method to design non-collision relative orbits for close spacecraft formation flying

    Science.gov (United States)

    Jiang, Wei; Li, JunFeng; Jiang, FangHua; Bernelli-Zazzera, Franco

    2018-05-01

    A set of linearized relative motion equations of spacecraft flying on unperturbed elliptical orbits are specialized for particular cases, where the leader orbit is circular or equatorial. Based on these extended equations, we are able to analyze the relative motion regulation between a pair of spacecraft flying on arbitrary unperturbed orbits with the same semi-major axis in close formation. Given the initial orbital elements of the leader, this paper presents a simple way to design initial relative orbital elements of close spacecraft with the same semi-major axis, thus preventing collision under non-perturbed conditions. Considering the mean influence of J 2 perturbation, namely secular J 2 perturbation, we derive the mean derivatives of orbital element differences, and then expand them to first order. Thus the first order expansion of orbital element differences can be added to the relative motion equations for further analysis. For a pair of spacecraft that will never collide under non-perturbed situations, we present a simple method to determine whether a collision will occur when J 2 perturbation is considered. Examples are given to prove the validity of the extended relative motion equations and to illustrate how the methods presented can be used. The simple method for designing initial relative orbital elements proposed here could be helpful to the preliminary design of the relative orbital elements between spacecraft in a close formation, when collision avoidance is necessary.

  7. A simple method for plasma total vitamin C analysis suitable for routine clinical laboratory use.

    Science.gov (United States)

    Robitaille, Line; Hoffer, L John

    2016-04-21

    In-hospital hypovitaminosis C is highly prevalent but almost completely unrecognized. Medical awareness of this potentially important disorder is hindered by the inability of most hospital laboratories to determine plasma vitamin C concentrations. The availability of a simple, reliable method for analyzing plasma vitamin C could increase opportunities for routine plasma vitamin C analysis in clinical medicine. Plasma vitamin C can be analyzed by high performance liquid chromatography (HPLC) with electrochemical (EC) or ultraviolet (UV) light detection. We modified existing UV-HPLC methods for plasma total vitamin C analysis (the sum of ascorbic and dehydroascorbic acid) to develop a simple, constant-low-pH sample reduction procedure followed by isocratic reverse-phase HPLC separation using a purely aqueous low-pH non-buffered mobile phase. Although EC-HPLC is widely recommended over UV-HPLC for plasma total vitamin C analysis, the two methods have never been directly compared. We formally compared the simplified UV-HPLC method with EC-HPLC in 80 consecutive clinical samples. The simplified UV-HPLC method was less expensive, easier to set up, required fewer reagents and no pH adjustments, and demonstrated greater sample stability than many existing methods for plasma vitamin C analysis. When compared with the gold-standard EC-HPLC method in 80 consecutive clinical samples exhibiting a wide range of plasma vitamin C concentrations, it performed equivalently. The easy set up, simplicity and sensitivity of the plasma vitamin C analysis method described here could make it practical in a normally equipped hospital laboratory. Unlike any prior UV-HPLC method for plasma total vitamin C analysis, it was rigorously compared with the gold-standard EC-HPLC method and performed equivalently. Adoption of this method could increase the availability of plasma vitamin C analysis in clinical medicine.

  8. A simple bacterial turbidimetric method for detection of some radurized foods

    International Nuclear Information System (INIS)

    Gautam, S.; Sharma, Arun; Thomas, Paul

    1998-01-01

    A simple and quick method for detection of irradiated food is proposed. The method is based on the principle of microbial contribution to the development of turbidity in a clear medium. It employs measurement of absorbance at 600 nm of the medium after the test commodity has been suspended and shaken in it for a fixed interval. The differences in the bacterial turbidity from irradiated and nonirradiated samples are quite marked so as to allow identification of the irradiated foods like fish, lamb meat, chicken and mushroom. (author)

  9. Accurate and simple measurement method of complex decay schemes radionuclide activity

    International Nuclear Information System (INIS)

    Legrand, J.; Clement, C.; Bac, C.

    1975-01-01

    A simple method for the measurement of the activity is described. It consists of using a well-type sodium iodide crystal whose efficiency mith monoenergetic photon rays has been computed or measured. For each radionuclide with a complex decay scheme a total efficiency is computed; it is shown that the efficiency is very high, near 100%. The associated incertainty is low, in spite of the important uncertainties on the different parameters used in the computation. The method has been applied to the measurement of the 152 Eu primary reference [fr

  10. A Simple Method for Measuring the Verticality of Small-Diameter Driven Wells

    DEFF Research Database (Denmark)

    Kjeldsen, Peter; Skov, Bent

    1994-01-01

    The presence of stones, solid waste, and other obstructions can deflect small-diameter driven wells during installation, leading to deviations of the well from its intended position. This could lead to erroneous results, especially for measurements of ground water levels by water level meters....... A simple method was developed to measure deviations from the intended positions of well screens and determine correction factors required for proper measurement of ground water levels in nonvertical wells. The method is based upon measurement of the hydrostatic pressure in the bottom of a water column...... ground water flow directions....

  11. A simple and rapid method of purification of impure plutonium oxide

    International Nuclear Information System (INIS)

    Michael, K.M.; Rakshe, P.R.; Dharmpurikar, G.R.; Thite, B.S.; Lokhande, Manisha; Sinalkar, Nitin; Dakshinamoorthy, A.; Munshi, S.K.; Dey, P.K.

    2007-01-01

    Impure plutonium oxides are conventionally purified by dissolution in HNO 3 in presence of HF followed by ion exchange separation and oxalate precipitation. The method is tedious and use of HF enhances corrosion of the plant equipment's. A simple and rapid method has been developed for the purification of the oxide by leaching with various reagents like DM water, NaOH and oxalic acid. A combination of DM water followed by hot leaching with 0.4 M oxalic acid could bring down the impurity levels in the oxide to the desired level required for fuel fabrication. (author)

  12. A simple source preparation method for alpha-ray spectrometry of volcanic rock sample

    International Nuclear Information System (INIS)

    Takahashi, Masaomi; Kurihara, Yuichi; Sato, Jun

    2006-01-01

    A simple source preparation method was developed for the alpha-ray spectrometry to determine U and Th in volcanic rockes. Isolation of U and Th from volcanic rocks was made by use of UTEVA-Spec. resin, extraction chromatograph material. U and Th were extracted by TTA-benzene solution and organic phase was evaporated drop by drop on a hot stainless steel planchet to dryness. This method was found to be effective for the preparation of sources for alpha-ray spectrometry. (author)

  13. A simple method of shower localization and identification in laterally segmented calorimeters

    International Nuclear Information System (INIS)

    Awes, T.C.; Obenshain, F.E.; Plasil, F.; Saini, S.; Young, G.R.; Sorensen, S.P.

    1992-01-01

    A method is proposed to calculate the first and second moments of the spatial distribution of the energy of electromagnetic and hadronic showers measured in laterally segmented colorimeters. The technique uses a logarithmic weighting of energy fraction observed in the individual detector cells. It is fast and simple requiring no fitting or complicated corrections for the position or angle of incidence. The method is demonstrated with GEANT simulations of a BGO detector array. The position resolution results and the e/π separation results are found to be equal or superior to those obtained with more complicated techniques. (orig.)

  14. A Simple Method for Prosthodontic Rehabilitation of Edentulous Patient with Epidermolysis Bullosa: A Clinical Case Report

    Directory of Open Access Journals (Sweden)

    Farhang Mahboub

    2011-06-01

    Full Text Available An abnormally small oral orifice is defined as microstomia. Microstomia may result from epidermolysis bullosa (EB, which consists of a group of disorders characterized by the presence of mechanical fragility of the skin with recurrent development of blisters and vesicles, resulting from minor mechanical friction or trauma. Since such patients have a small oral aperture, it may be impossible to take impression and fabricate dentures using conventional methods. In this article, a simple method for taking preliminary impressions from upper and lower edentulous ridges in one patient with limited mouth opening and then preparing the complete denture with custom denture teeth in a single unit was described.

  15. Simple method for evaluating Goldstone diagrams in an angular momentum coupled representation

    International Nuclear Information System (INIS)

    Kuo, T.T.S.; Shurpin, J.; Tam, K.C.; Osnes, E.; Ellis, P.J.

    1981-01-01

    A simple and convenient method is derived for evaluating linked Goldstone diagrams in an angular momentum coupled representation. Our method is general, and can be used to evaluate any effective interaction and/or effective operator diagrams for both closed-shell nuclei (vacuum to vacuum linked diagrams) and open-shell nuclei (valence linked diagrams). The techniques of decomposing diagrams into ladder diagrams, cutting open internal lines and cutting off one-body insertions are introduced. These enable us to determine angular momentum factors associated with diagrams in the coupled representation directly, without the need for carrying out complicated angular momentum algebra. A summary of diagram rules is given

  16. Biological evaluation and simple method for the synthesis of tetrahydrobenzo[a]xanthenes-11-one derivatives

    Directory of Open Access Journals (Sweden)

    Ali Akbari

    2017-01-01

    Full Text Available A simple method for the synthesis of Tetrahydrobenzo[a]xanthenes-11-one derivatives in the presence of BF3.SiO2, and its antibacterial activity was assessed against Pseudomonas syringae, Xanthomonas citi and Pectobacterium carotovorum. The structure of the isolated compounds has been determined by means of 1H/13C NMR and FT-IR spectroscopy. The reactions were carried out in water at room temperature for 5 h. This method has some advantages such as good to excellent yield, mild reaction condition, ease of operation and workup, high product purity and green process.

  17. A Nonmonotone Trust Region Method for Nonlinear Programming with Simple Bound Constraints

    International Nuclear Information System (INIS)

    Chen, Z.-W.; Han, J.-Y.; Xu, D.-C.

    2001-01-01

    In this paper we propose a nonmonotone trust region algorithm for optimization with simple bound constraints. Under mild conditions, we prove the global convergence of the algorithm. For the monotone case it is also proved that the correct active set can be identified in a finite number of iterations if the strict complementarity slackness condition holds, and so the proposed algorithm reduces finally to an unconstrained minimization method in a finite number of iterations, allowing a fast asymptotic rate of convergence. Numerical experiments show that the method is efficient

  18. Simple method for assembly of CRISPR synergistic activation mediator gRNA expression array.

    Science.gov (United States)

    Vad-Nielsen, Johan; Nielsen, Anders Lade; Luo, Yonglun

    2018-05-20

    When studying complex interconnected regulatory networks, effective methods for simultaneously manipulating multiple genes expression are paramount. Previously, we have developed a simple method for generation of an all-in-one CRISPR gRNA expression array. We here present a Golden Gate Assembly-based system of synergistic activation mediator (SAM) compatible CRISPR/dCas9 gRNA expression array for the simultaneous activation of multiple genes. Using this system, we demonstrated the simultaneous activation of the transcription factors, TWIST, SNAIL, SLUG, and ZEB1 a human breast cancer cell line. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Note on a simple test method for estimaing J/sub Ic/

    International Nuclear Information System (INIS)

    Whipple, T.A.; McHenry, H.I.

    1980-01-01

    Fracture toughness testing is generally a time-consuming and expensive procedure; therefore, there has been a significant amount of effort directed toward developing an inexpensive and rapid method of estimating the fracture toughness of materials. In this paper, a simple method for estimating J/sub Ic/ through the use of small, notched, bend bars is evaluated. The test only involves the measurement of the energy necessary to fracture the sample. Initial tests on Fe-18Cr-3Ni-13Mn and 304L stainless steel at 76 and 4 0 K have yielded results consistent with other fracture toughness tests, for materials in the low- to medium-toughness range

  20. Validation of a simple method for predicting the disinfection performance in a flow-through contactor.

    Science.gov (United States)

    Pfeiffer, Valentin; Barbeau, Benoit

    2014-02-01

    Despite its shortcomings, the T10 method introduced by the United States Environmental Protection Agency (USEPA) in 1989 is currently the method most frequently used in North America to calculate disinfection performance. Other methods (e.g., the Integrated Disinfection Design Framework, IDDF) have been advanced as replacements, and more recently, the USEPA suggested the Extended T10 and Extended CSTR (Continuous Stirred-Tank Reactor) methods to improve the inactivation calculations within ozone contactors. To develop a method that fully considers the hydraulic behavior of the contactor, two models (Plug Flow with Dispersion and N-CSTR) were successfully fitted with five tracer tests results derived from four Water Treatment Plants and a pilot-scale contactor. A new method based on the N-CSTR model was defined as the Partially Segregated (Pseg) method. The predictions from all the methods mentioned were compared under conditions of poor and good hydraulic performance, low and high disinfectant decay, and different levels of inactivation. These methods were also compared with experimental results from a chlorine pilot-scale contactor used for Escherichia coli inactivation. The T10 and Extended T10 methods led to large over- and under-estimations. The Segregated Flow Analysis (used in the IDDF) also considerably overestimated the inactivation under high disinfectant decay. Only the Extended CSTR and Pseg methods produced realistic and conservative predictions in all cases. Finally, a simple implementation procedure of the Pseg method was suggested for calculation of disinfection performance. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. A simple method to approximate liver size on cross-sectional images using living liver models

    International Nuclear Information System (INIS)

    Muggli, D.; Mueller, M.A.; Karlo, C.; Fornaro, J.; Marincek, B.; Frauenfelder, T.

    2009-01-01

    Aim: To assess whether a simple. diameter-based formula applicable to cross-sectional images can be used to calculate the total liver volume. Materials and methods: On 119 cross-sectional examinations (62 computed tomography and 57 magnetic resonance imaging) a simple, formula-based method to approximate the liver volume was evaluated. The total liver volume was approximated measuring the largest craniocaudal (cc), ventrodorsal (vd), and coronal (cor) diameters by two readers and implementing the equation: Vol estimated =ccxvdxcorx0.31. Inter-rater reliability, agreement, and correlation between liver volume calculation and virtual liver volumetry were analysed. Results: No significant disagreement between the two readers was found. The formula correlated significantly with the volumetric data (r > 0.85, p < 0.0001). In 81% of cases the error of the approximated volume was <10% and in 92% of cases <15% compared to the volumetric data. Conclusion: Total liver volume can be accurately estimated on cross-sectional images using a simple, diameter-based equation.

  2. Determination of Urine Albumin by New Simple High-Performance Liquid Chromatography Method.

    Science.gov (United States)

    Klapkova, Eva; Fortova, Magdalena; Prusa, Richard; Moravcova, Libuse; Kotaska, Karel

    2016-11-01

    A simple high-performance liquid chromatography (HPLC) method was developed for the determination of albumin in patients' urine samples without coeluting proteins and was compared with the immunoturbidimetric determination of albumin. Urine albumin is important biomarker in diabetic patients, but part of it is immuno-nonreactive. Albumin was determined by high-performance liquid chromatography (HPLC), UV detection at 280 nm, Zorbax 300SB-C3 column. Immunoturbidimetric analysis was performed using commercial kit on automatic biochemistry analyzer COBAS INTEGRA ® 400, Roche Diagnostics GmbH, Manheim, Germany. The HLPC method was fully validated. No significant interference with other proteins (transferrin, α-1-acid glycoprotein, α-1-antichymotrypsin, antitrypsin, hemopexin) was found. The results from 301 urine samples were compared with immunochemical determination. We found a statistically significant difference between these methods (P = 0.0001, Mann-Whitney test). New simple HPLC method was developed for the determination of urine albumin without coeluting proteins. Our data indicate that the HPLC method is highly specific and more sensitive than immunoturbidimetry. © 2016 Wiley Periodicals, Inc.

  3. Determination of Some Cephalosporins in Pharmaceutical Formulations by a Simple and Sensitive Spectrofluorimetric Method

    Directory of Open Access Journals (Sweden)

    Ali Abdollahi, Ahad Bavili-Tabrizi

    2016-03-01

    Full Text Available Background: Cephalosporins are among the safest and the most effective broad-spectrum bactericidal antimicrobial agents which have been prescribed by the clinician as antibiotics. Thus, the developing of simple, sensitive and rapid analytical methods for their determination can be attractive and desirable. Methods: A simple, rapid and sensitive spectrofluorimetric method was developed for the determination of cefixime, cefalexin and ceftriaxone in pharmaceutical formulations. Proposed method is based on the oxidation of these cephalosporins with cerium (IV to produce cerium (III, and its fluorescence was monitored at 356 ± 3 nm after excitation at 254 ± 3 nm. Results: The variables effecting oxidation of each cephalosporin with cerum (IV were studied and optimized. Under the experimental conditions used, the calibration graphs were linear over the range 0.1-4 µg/mL. The limit of detection and limit of quantification were in the range 0.031-0.054 and 0.102-0.172 µg/mL, respectively. Intra- and inter-day assay precisions, expressed as the relative standard deviation (RSD, were lower than 5.6 and 6.8%, respectively. Conclusion: The proposed method was applied to the determination of studied cephalosporins in pharmaceutical formulations by good recoveries in the range 91-110%.

  4. Simple method for absolute calibration of geophones, seismometers, and other inertial vibration sensors

    International Nuclear Information System (INIS)

    Kann, Frank van; Winterflood, John

    2005-01-01

    A simple but powerful method is presented for calibrating geophones, seismometers, and other inertial vibration sensors, including passive accelerometers. The method requires no cumbersome or expensive fixtures such as shaker platforms and can be performed using a standard instrument commonly available in the field. An absolute calibration is obtained using the reciprocity property of the device, based on the standard mathematical model for such inertial sensors. It requires only simple electrical measurement of the impedance of the sensor as a function of frequency to determine the parameters of the model and hence the sensitivity function. The method is particularly convenient if one of these parameters, namely the suspended mass is known. In this case, no additional mechanical apparatus is required and only a single set of impedance measurements yields the desired calibration function. Moreover, this measurement can be made with the device in situ. However, the novel and most powerful aspect of the method is its ability to accurately determine the effective suspended mass. For this, the impedance measurement is made with the device hanging from a simple spring or flexible cord (depending on the orientation of its sensitive axis). To complete the calibration, the device is weighed to determine its total mass. All the required calibration parameters, including the suspended mass, are then determined from a least-squares fit to the impedance as a function of frequency. A demonstration using both a 4.5 Hz geophone and a 1 Hz seismometer shows that the method can yield accurate absolute calibrations with an error of 0.1% or better, assuming no a priori knowledge of any parameters

  5. An Operationally Simple Method for Separating the Rare-Earth Elements Neodymium and Dysprosium.

    Science.gov (United States)

    Bogart, Justin A; Lippincott, Connor A; Carroll, Patrick J; Schelter, Eric J

    2015-07-06

    Rare-earth metals are critical components of electronic materials and permanent magnets. Recycling of consumer materials is a promising new source of rare earths. To incentivize recycling there is a clear need for simple methods for targeted separations of mixtures of rare-earth metal salts. Metal complexes of a tripodal nitroxide ligand [{(2-(t) BuNO)C6 H4 CH2 }3 N](3-) (TriNOx(3-) ), feature a size-sensitive aperture formed of its three η(2) -(N,O) ligand arms. Exposure of metal cations in the aperture induces a self-associative equilibrium comprising [M(TriNOx)thf]/ [M(TriNOx)]2 (M=rare-earth metal). Differences in the equilibrium constants (Keq ) for early and late metals enables simple Nd/Dy separations through leaching with a separation ratio SNd/Dy =359. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Machine learning plus optical flow: a simple and sensitive method to detect cardioactive drugs

    Science.gov (United States)

    Lee, Eugene K.; Kurokawa, Yosuke K.; Tu, Robin; George, Steven C.; Khine, Michelle

    2015-07-01

    Current preclinical screening methods do not adequately detect cardiotoxicity. Using human induced pluripotent stem cell-derived cardiomyocytes (iPS-CMs), more physiologically relevant preclinical or patient-specific screening to detect potential cardiotoxic effects of drug candidates may be possible. However, one of the persistent challenges for developing a high-throughput drug screening platform using iPS-CMs is the need to develop a simple and reliable method to measure key electrophysiological and contractile parameters. To address this need, we have developed a platform that combines machine learning paired with brightfield optical flow as a simple and robust tool that can automate the detection of cardiomyocyte drug effects. Using three cardioactive drugs of different mechanisms, including those with primarily electrophysiological effects, we demonstrate the general applicability of this screening method to detect subtle changes in cardiomyocyte contraction. Requiring only brightfield images of cardiomyocyte contractions, we detect changes in cardiomyocyte contraction comparable to - and even superior to - fluorescence readouts. This automated method serves as a widely applicable screening tool to characterize the effects of drugs on cardiomyocyte function.

  7. A Comparison of Multidimensional Item Selection Methods in Simple and Complex Test Designs

    Directory of Open Access Journals (Sweden)

    Eren Halil ÖZBERK

    2017-03-01

    Full Text Available In contrast with the previous studies, this study employed various test designs (simple and complex which allow the evaluation of the overall ability score estimations across multiple real test conditions. In this study, four factors were manipulated, namely the test design, number of items per dimension, correlation between dimensions and item selection methods. Using the generated item and ability parameters, dichotomous item responses were generated in by using M3PL compensatory multidimensional IRT model with specified correlations. MCAT composite ability score accuracy was evaluated using absolute bias (ABSBIAS, correlation and the root mean square error (RMSE between true and estimated ability scores. The results suggest that the multidimensional test structure, number of item per dimension and correlation between dimensions had significant effect on item selection methods for the overall score estimations. For simple structure test design it was found that V1 item selection has the lowest absolute bias estimations for both long and short tests while estimating overall scores. As the model gets complex KL item selection method performed better than other two item selection method.

  8. Measurement of radiocesium concentration in trees using cumulative gamma radiation dose rate detection systems - A simple presumption for radiocesium concentration in living woods using glass-badge based gamma radiation dose rate detection system

    Energy Technology Data Exchange (ETDEWEB)

    Yoshihara, T.; Hashida, S.N. [Plant Molecular Biology, Laboratory of Environmental Science, Central Research Institute of Electric Power Industry (CRIEPI), 1646 Abiko, Chiba 270-1194 (Japan); Kawachi, N.; Suzui, N.; Yin, Y.G.; Fujimaki, S. [Radiotracer Imaging Gr., Quantum Beam Science Center, Japan Atomic Energy Agency (JAEA), 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan); Nagao, Y.; Yamaguchi, M. [Takasaki Advanced Radiation Research Institute, Japan Atomic Energy Agency (JAEA), 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan)

    2014-07-01

    Radiocesium from the severe accident at the Fukushima Dai-ichi Nuclear Power Plant on 11 March 2011 contaminates large areas. After this, a doubt for forest products, especially of mushroom, is indelible at the areas. Pruned woody parts and litters are containing a considerable amount of radiocesium, and generates a problem at incineration and composting. These mean that more attentive survey for each subject is expected; however, the present survey system is highly laborious/expensive and/or non-effective for this purpose. On the other hand, we can see a glass-badge based gamma radiation dose rate detection system. This system always utilized to detect a personal cumulative radiation dose, and thus, it is not suitable to separate a radiation from a specific object. However, if we can separate a radiation from a specific object and relate it with the own radiocesium concentration, it would enable us to presume the specific concentration with just an easy monitoring but without a destruction of the target nature and a complicated process including sampling, pre-treatment, and detection. Here, we present the concept of the measurement and results of the trials. First, we set glass-badges (type FS, Chiyoda Technol Corp., Japan) on a part of bough (approximately 10 cm in diameter) of Japanese flowering cherry trees (Prunus x yedoensis cv. Somei-Yoshino) with four different settings: A, a direct setting without any shield; B, a setting with an aluminum shield between bough and the glass-badge; C, a setting with a lead shield between bough and the glass-badge; D, a setting with a lead shield covering the glass-badge to shut the radiation from the surrounding but from bough. The deduction between the amount of each setting should separate a specific radiation of the bough from unlimited radiation from the surrounding. Even if the hourly dose rate is not enough to count the difference, a moderate cumulative dose would clear the difference. In fact, results demonstrated a

  9. A simple mass-conserved level set method for simulation of multiphase flows

    Science.gov (United States)

    Yuan, H.-Z.; Shu, C.; Wang, Y.; Shu, S.

    2018-04-01

    In this paper, a modified level set method is proposed for simulation of multiphase flows with large density ratio and high Reynolds number. The present method simply introduces a source or sink term into the level set equation to compensate the mass loss or offset the mass increase. The source or sink term is derived analytically by applying the mass conservation principle with the level set equation and the continuity equation of flow field. Since only a source term is introduced, the application of the present method is as simple as the original level set method, but it can guarantee the overall mass conservation. To validate the present method, the vortex flow problem is first considered. The simulation results are compared with those from the original level set method, which demonstrates that the modified level set method has the capability of accurately capturing the interface and keeping the mass conservation. Then, the proposed method is further validated by simulating the Laplace law, the merging of two bubbles, a bubble rising with high density ratio, and Rayleigh-Taylor instability with high Reynolds number. Numerical results show that the mass is a well-conserved by the present method.

  10. A simple method for fabricating multi-layer PDMS structures for 3D microfluidic chips

    KAUST Repository

    Zhang, Mengying

    2010-01-01

    We report a simple methodology to fabricate PDMS multi-layer microfluidic chips. A PDMS slab was surface-treated by trichloro (1H,1H,2H,2H-perfluorooctyl) silane, and acts as a reusable transferring layer. Uniformity of the thickness of the patterned PDMS layer and the well-alignment could be achieved due to the transparency and proper flexibility of this transferring layer. Surface treatment results are confirmed by XPS and contact angle testing, while bonding forces between different layers were measured for better understanding of the transferring process. We have also designed and fabricated a few simple types of 3D PDMS chip, especially one consisting of 6 thin layers (each with thickness of 50 μm), to demonstrate the potential utilization of this technique. 3D fluorescence images were taken by a confocal microscope to illustrate the spatial characters of essential parts. This fabrication method is confirmed to be fast, simple, repeatable, low cost and possible to be mechanized for mass production. © The Royal Society of Chemistry 2010.

  11. Ruminal Methane Production on Simple Phenolic Acids Addition in in Vitro Gas Production Method

    Directory of Open Access Journals (Sweden)

    A. Jayanegara

    2009-04-01

    Full Text Available Methane production from ruminants contributes to total global methane production, which is an important contributor to global warming. In this experiment, six sources of simple phenolic acids (benzoic, cinnamic, phenylacetic, caffeic, p-coumaric and ferulic acids at two different levels (2 and 5 mM added to hay diet were evaluated for their potential to reduce enteric methane production using in vitro Hohenheim gas production method. The measured variables were gas production, methane, organic matter digestibility (OMD, and short chain fatty acids (SCFA. The results showed that addition of cinnamic, caffeic, p-coumaric and ferulic acids at 5 mM significantly (P p-coumaric > ferulic > cinnamic. The addition of simple phenols did not significantly decrease OMD. Addition of simple phenols tends to decrease total SCFA production. It was concluded that methane decrease by addition of phenolic acids was relatively small, and the effect of phenolic acids on methane decrease depended on the source and concentration applied.

  12. Stochastic Order Redshift Technique (SORT): a simple, efficient and robust method to improve cosmological redshift measurements

    Science.gov (United States)

    Tejos, Nicolas; Rodríguez-Puebla, Aldo; Primack, Joel R.

    2018-01-01

    We present a simple, efficient and robust approach to improve cosmological redshift measurements. The method is based on the presence of a reference sample for which a precise redshift number distribution (dN/dz) can be obtained for different pencil-beam-like sub-volumes within the original survey. For each sub-volume we then impose that: (i) the redshift number distribution of the uncertain redshift measurements matches the reference dN/dz corrected by their selection functions and (ii) the rank order in redshift of the original ensemble of uncertain measurements is preserved. The latter step is motivated by the fact that random variables drawn from Gaussian probability density functions (PDFs) of different means and arbitrarily large standard deviations satisfy stochastic ordering. We then repeat this simple algorithm for multiple arbitrary pencil-beam-like overlapping sub-volumes; in this manner, each uncertain measurement has multiple (non-independent) 'recovered' redshifts which can be used to estimate a new redshift PDF. We refer to this method as the Stochastic Order Redshift Technique (SORT). We have used a state-of-the-art N-body simulation to test the performance of SORT under simple assumptions and found that it can improve the quality of cosmological redshifts in a robust and efficient manner. Particularly, SORT redshifts (zsort) are able to recover the distinctive features of the so-called 'cosmic web' and can provide unbiased measurement of the two-point correlation function on scales ≳4 h-1Mpc. Given its simplicity, we envision that a method like SORT can be incorporated into more sophisticated algorithms aimed to exploit the full potential of large extragalactic photometric surveys.

  13. A bivariate optimal replacement policy with cumulative repair cost ...

    Indian Academy of Sciences (India)

    Min-Tsai Lai

    Shock model; cumulative damage model; cumulative repair cost limit; preventive maintenance model. 1. Introduction ... with two types of shocks: one type is failure shock, and the other type is damage ...... Theory, methods and applications.

  14. Thermalization calorimetry: A simple method for investigating glass transition and crystallization of supercooled liquids

    DEFF Research Database (Denmark)

    Jakobsen, Bo; Sanz, Alejandro; Niss, Kristine

    2016-01-01

    and their crystallization, e.g., for locating the glass transition and melting point(s), as well as for investigating the stability against crystallization and estimating the relative change in specific heat between the solid and liquid phases at the glass transition......We present a simple method for fast and cheap thermal analysis on supercooled glass-forming liquids. This “Thermalization Calorimetry” technique is based on monitoring the temperature and its rate of change during heating or cooling of a sample for which the thermal power input comes from heat...

  15. A simple method for conversion of airborne gamma-ray spectra to ground level doses

    DEFF Research Database (Denmark)

    Korsbech, Uffe C C; Bargholz, Kim

    1996-01-01

    A new and simple method for conversion of airborne NaI(Tl) gamma-ray spectra to dose rates at ground level has been developed. By weighting the channel count rates with the channel numbers a spectrum dose index (SDI) is calculated for each spectrum. Ground level dose rates then are determined...... by multiplying the SDI by an altitude dependent conversion factor. The conversion factors are determined from spectra based on Monte Carlo calculations. The results are compared with measurements in a laboratory calibration set-up. IT-NT-27. June 1996. 27 p....

  16. A simple and effective method for detecting precipitated proteins in MALDI-TOF MS.

    Science.gov (United States)

    Oshikane, Hiroyuki; Watabe, Masahiko; Nakaki, Toshio

    2018-04-01

    MALDI-TOF MS has developed rapidly into an essential analytical tool for the life sciences. Cinnamic acid derivatives are generally employed in routine molecular weight determinations of intact proteins using MALDI-TOF MS. However, a protein of interest may precipitate when mixed with matrix solution, perhaps preventing MS detection. We herein provide a simple approach to enable the MS detection of such precipitated protein species by means of a "direct deposition method" -- loading the precipitant directly onto the sample plate. It is thus expected to improve routine MS analysis of intact proteins. Copyright © 2018. Published by Elsevier Inc.

  17. Simple emittance measurement of negative hydrogen ion beam using pepper-pot method

    International Nuclear Information System (INIS)

    Hamabe, M.; Tsumori, K.; Takeiri, Y.; Kaneko, O.; Asano, E.; Kawamoto, T.; Kuroda, T.; Guharay, S.K.

    1997-01-01

    A simple apparatus for emittance measurement using pepper-pot method is developed. The pepper-pot patterns are directly exposed and recorded on a Kapton foil. Using this apparatus, emittance was measured in the case of the negative hydrogen (H - ) beam from the large negative ion source, which is the 1/3 scaled test device for the negative-ion-based neutral beam injection (N-NBI) on the Large Helical Device (LHD). As the consequence of the first trial, the 95% normalized emittance value is measured as 0.59 mm mrad. (author)

  18. Simple and efficient method for isolation and cultivation of endoscopically obtained human colonocytes

    DEFF Research Database (Denmark)

    Seidelin, Jakob B; Horn, Thomas; Nielsen, Ole H

    2003-01-01

    and where the diagnosis of irritable bowel syndrome was later reached, were included. Seven colon biopsies were taken and incubated at varying time periods of 10-120 min and temperatures of 4-37 degrees C in a chelating buffer. The epithelium was then harvested and cultivated under three different......Few comparative and validated reports exist on the isolation and growth of colonoscopically obtained colonic epithelium. The aim of this study was to develop and validate a simple method for the cultivation of colonoscopically obtained colonocytes. Forty patients, who underwent routine colonoscopy...

  19. Simple Method of Preparation and Characterization of New Antifungal Active Biginelli Type Heterocyclic Compounds

    Science.gov (United States)

    Velan, A. Senthilkumara; Joseph, J.; Raman, N.

    2008-01-01

    A simple, efficient and cost effective method is described for the synthesis of Biginelli type heterocyclic compounds of dihydropyrimidinones analogous. They were prepared from a reaction mixture consisting of substituted benzaldehydes, thiourea and ethylacetoacetate using ammonium dihydrogenphosphate as catalyst. The procedure for the preparation of the compounds is environmentally benign and safe which is advantageous in terms of experimentation, catalyst reusability, yields of the products, shorter reaction times and preclusion of toxic solvents. The four new synthesised compounds were tested for their antifungal activity. They have good antifungal activity comparing to the standard (Fluconazole). PMID:23997611

  20. A simple method for the preparation of activated carbon fibers coated with graphite nanofibers.

    Science.gov (United States)

    Kim, Byung-Joo; Park, Soo-Jin

    2007-11-15

    A simple method is described for the preparation of activated carbon fibers (ACFs) coated with graphite nanofibers (GNFs). Low-pressure-plasma mixed-gas (Ar/O2) treatment of the ACFs led to the growth of GNFs on their surface. The growth was greater at higher power inputs, and from TEM observations the GNFs were seen to be of herringbone type. It was found that the N2 adsorption capacity of the ACFs did not sharply decrease, and that volume resistivity of the ACFs enhanced as a result of this treatment.

  1. A simple method to prepare self-assembled organic-organic heterobilayers on metal substrates

    Directory of Open Access Journals (Sweden)

    L. D. Sun

    2011-06-01

    Full Text Available We demonstrate a self-assembly based simple method to prepare organic-organic heterobilayers on a metal substrate. By either sequential- or co-deposition of para-sexiphenyl (p-6P and pentacene molecules onto the Cu(110 surface in ultrahigh vacuum, p-6P/pentacene/Cu(110 heterobilayer is synthesized at room temperature. The layer sequence of the heterostructure is independent of the growth scenario indicating the p-6P/pentacene/Cu(110 is a self-assembled structure with lowest energy. Besides, the bilayer shows a very high orientational ordering and is thermally stable up to 430K.

  2. Simple method for identifying doubly ionized uranium (U III) produced in a hollow-cathode discharge

    International Nuclear Information System (INIS)

    Piyakis, K.N.; Gagne, J.M.

    1988-01-01

    We have studied by emission spectroscopy the spectral properties of doubly ionized uranium, produced in a vapor generator of hollow-cathode design, as a function of the nature of a pure fill gas (helium, neon, argon, krypton, xenon) and its pressure. The spectral intensity is found to increase with increasing ionization potential of the discharge buffer gas, except in the case of helium. Based on our preliminary results, a simple and practical method for the positive identification of the complex U III spectrum is suggested

  3. Simple emittance measurement of negative hydrogen ion beam using pepper-pot method

    Energy Technology Data Exchange (ETDEWEB)

    Hamabe, M.; Tsumori, K.; Takeiri, Y.; Kaneko, O.; Asano, E.; Kawamoto, T.; Kuroda, T. [National Inst. for Fusion Science, Nagoya (Japan); Guharay, S.K.

    1997-02-01

    A simple apparatus for emittance measurement using pepper-pot method is developed. The pepper-pot patterns are directly exposed and recorded on a Kapton foil. Using this apparatus, emittance was measured in the case of the negative hydrogen (H{sup -}) beam from the large negative ion source, which is the 1/3 scaled test device for the negative-ion-based neutral beam injection (N-NBI) on the Large Helical Device (LHD). As the consequence of the first trial, the 95% normalized emittance value is measured as 0.59 mm mrad. (author)

  4. Tracing and quantifying groundwater inflow into lakes using a simple method for radon-222 analysis

    Directory of Open Access Journals (Sweden)

    T. Kluge

    2007-09-01

    Full Text Available Due to its high activities in groundwater, the radionuclide 222Rn is a sensitive natural tracer to detect and quantify groundwater inflow into lakes, provided the comparatively low activities in the lakes can be measured accurately. Here we present a simple method for radon measurements in the low-level range down to 3 Bq m−3, appropriate for groundwater-influenced lakes, together with a concept to derive inflow rates from the radon budget in lakes. The analytical method is based on a commercially available radon detector and combines the advantages of established procedures with regard to efficient sampling and sensitive analysis. Large volume (12 l water samples are taken in the field and analyzed in the laboratory by equilibration with a closed air loop and alpha spectrometry of radon in the gas phase. After successful laboratory tests, the method has been applied to a small dredging lake without surface in- or outflow in order to estimate the groundwater contribution to the hydrological budget. The inflow rate calculated from a 222Rn balance for the lake is around 530 m³ per day, which is comparable to the results of previous studies. In addition to the inflow rate, the vertical and horizontal radon distribution in the lake provides information on the spatial distribution of groundwater inflow to the lake. The simple measurement and sampling technique encourages further use of radon to examine groundwater-lake water interaction.

  5. Control of Solar Power Plants Connected Grid with Simple Calculation Method on Residential Homes

    Science.gov (United States)

    Kananda, Kiki; Nazir, Refdinal

    2017-12-01

    One of the most compatible renewable energy in all regions to apply is solar energy. Solar power plants can be built connected to existing or stand-alone power grids. In assisting the residential electricity in which there is a power grid, then a small scale solar energy power plants is very appropriate. However, the general constraint of solar energy power plants is still low in terms of efficiency. Therefore, this study will explain how to control the power of solar power plants more optimally, which is expected to reactive power to zero to raise efficiency. This is a continuation of previous research using Newton Rapshon control method. In this study we introduce a simple method by using ordinary mathematical calculations of solar-related equations. In this model, 10 PV modules type of ND T060M1 with a 60 Wp capacity are used. The calculations performed using MATLAB Simulink provide excellent value. For PCC voltage values obtained a stable quantity of approximately 220 V. At a maximum irradiation condition of 1000 W / m2, the reactive power value of Q solar generating system maximum 20.48 Var and maximum active power of 417.5 W. In the condition of lower irradiation, value of reactive power Q almost close to zero 0.77Var. This simple mathematical method can provide excellent quality control power values.

  6. A Simple Method for Assessing Severity of Common Root Rot on Barley

    Directory of Open Access Journals (Sweden)

    Mohammad Imad Eddin Arabi

    2013-12-01

    Full Text Available Common root rot caused by Cochliobolus sativus is a serious disease of barley. A simple and reliable method for assessing this disease would enhance our capacity in identifying resistance sources and developing resistant barley cultivars. In searching for such a method, a conidial suspension of C. sativus was dropped onto sterilized elongated subcrown internodes and incubated in sandwich filter paper using polyethylene transparent envelopes. Initial disease symptoms were easily detected after 48h of inoculation. Highly significant correlation coefficients were found in each experiment (A, B and C between sandwich filter paper and seedling assays, indicating that this testing procedure was reliable. The method presented facilitates a rapid pre-selection under uniform conditions which is of importance from a breeder’s point of view.

  7. Simple method for functionalization of silica with alkyl silane and organic ligands

    Directory of Open Access Journals (Sweden)

    Kasim Mohammed Hello

    2018-06-01

    Full Text Available 3–(chloropropyltriethoxysilane (CPTES with imidazole and sodium silicate from rice husk ash (RHA successfully reacted within a short time in one–pot synthesis in purely homogenous method. A similar procedure was used for the immobilization of melamine and saccharine to demonstrate a generally applicable method. No reflux was needed, and a green solvent was used as the reaction medium. The surface areas of the prepared materials were very high compared with the materials which have similar structure prepared by the traditional method. The TGA/DTA confirmed that all the materials were highly stable. The FT-IR shows that all expected the functional groups were present. The HRTEM showed that the materials had ordered mesoporous straight-channels which were like the MCM-41. The synthesis procedure is simple, repeatable with different organic ligands and does not require toxic solvents or multiple steps with high products yield. Keywords: Rice husk ash, MCM-41, Imidazole, Melamine, Saccharine

  8. Simple measurement of 14C in the environment using a gel suspension method

    International Nuclear Information System (INIS)

    Wakabayashi, G.; Ohura, H.; Okai, T.; Matoba, M.

    1999-01-01

    A simple analytical method for environmental 14 C with a low background liquid scintillation counter was developed. A new gelling agent, N-lauroyl-L-glutamic-α,γ-dibutylamide was used, for the liquid scintillation counting of 14 C as CaCO 3 (gel suspension method). Our procedure for sample preparation was much simpler than that of conventional methods and required no special equipment. The samples prepared with the standard sample of CaCO 3 were measured to evaluate the self absorption of the sample, the optimum condition of counting and the detection limit. Our results indicated that the newly developed technique could be efficiently applied for the monitoring of environmental 14 C. (author)

  9. A simple in situ visual and tristimulus colorimetric method for the determination of diphosgene in air

    Directory of Open Access Journals (Sweden)

    VLADIMÍR PITSCHMANN

    2007-10-01

    Full Text Available A simple visual and tristimulus colorimetric method (three-dimensional system CIE–L*a*b* for the determination of trace amounts of diphosgene in air has been developed. The method is based on the suction of diphosgene vapors through a modified cotton fabric filter fixed in a special adapter. Prior to analysis, the filter is saturated with a chromogenic reagent based on 4-(p-nitrobenzylpyridine. The optimal composition of the reagent is 2 g of 4-(p-nitrobenzylpyridine and 4 g of N-phenylbenzylamine in 100 ml of a 50:50 ethanol–glycerol mixture. The intensity of the formed red coloration of the filter is evaluated visually or by a tristimulus colorimeter (LMG 173, Lange, Germany. The detection limit is 0.01 mg m-3. Acetyl chloride and benzoyl chloride react in 150 and 50 times higher concentrations, respecttively. The method is suitable for mobile field analysis.

  10. Experimental Verification of a Simple Method for Accurate Center of Gravity Determination of Small Satellite Platforms

    Directory of Open Access Journals (Sweden)

    Dario Modenini

    2018-01-01

    Full Text Available We propose a simple and relatively inexpensive method for determining the center of gravity (CoG of a small spacecraft. This method, which can be ascribed to the class of suspension techniques, is based on dual-axis inclinometer readings. By performing two consecutive suspensions from two different points, the CoG is determined, ideally, as the intersection between two lines which are uniquely defined by the respective rotations. We performed an experimental campaign to verify the method and assess its accuracy. Thanks to a quantitative error budget, we obtained an error distribution with simulations, which we verified through experimental tests. The retrieved experimental error distribution agrees well with the results predicted through simulations, which in turn lead to a CoG error norm smaller than 2 mm with 95% confidence level.

  11. About the method of approximation of a simple closed plane curve with a sharp edge

    Directory of Open Access Journals (Sweden)

    Zelenyy A.S.

    2017-02-01

    Full Text Available it was noted in the article, that initially the problem of interpolation of the simple plane curve arose in the problem of simulation of subsonic flow around a body with the subsequent calculation of the velocity potential using the vortex panel method. However, as it turned out, the practical importance of this method is much wider. This algorithm can be successfully applied in any task that requires a discrete set of points which describe an arbitrary curve: potential function method, flow around an airfoil with the trailing edge (airfoil, liquid drop, etc., analytic expression, which is very difficult to obtain, creation of the font and logo and in some tasks of architecture and garment industry.

  12. A simple component-connection method for building binary decision diagrams encoding a fault tree

    International Nuclear Information System (INIS)

    Way, Y.-S.; Hsia, D.-Y.

    2000-01-01

    A simple new method for building binary decision diagrams (BDDs) encoding a fault tree (FT) is provided in this study. We first decompose the FT into FT-components. Each of them is a single descendant (SD) gate-sequence. Following the node-connection rule, the BDD-component encoding an SD FT-component can each be found to be an SD node-sequence. By successively connecting the BDD-components one by one, the BDD for the entire FT is thus obtained. During the node-connection and component-connection, reduction rules might need to be applied. An example FT is used throughout the article to explain the procedure step by step. Our method proposed is a hybrid one for FT analysis. Some algorithms or techniques used in the conventional FT analysis or the newer BDD approach may be applied to our case; our ideas mentioned in the article might be referred by the two methods

  13. Application to Determination of Scholarship Worthiness Using Simple Multi Attribute Rating Technique and Merkle Hellman Method

    Directory of Open Access Journals (Sweden)

    Dicky Nofriansyah

    2017-10-01

    Full Text Available This research was focused on explaining how the concept of simple multi attribute rating technique method in a decision support system based on desktop programming to solve multi-criteria selection problem, especially Scholarship. The Merkle Hellman method is used for securing the results of choices made by the Smart process. The determination of PPA and BBP-PPA scholarship recipients on STMIK Triguna Dharma becomes a problem because it takes a long time in determining the decision. By adopting the SMART method, the application can make decisions quickly and precisely. The expected result of this research is the application can facilitate in overcoming the problems that occur concerning the determination of PPA and BBP-PPA scholarship recipients as well as assisting Student Affairs STMIK Triguna Dharma in making decisions quickly and accurately

  14. Note: A simple image processing based fiducial auto-alignment method for sample registration.

    Science.gov (United States)

    Robertson, Wesley D; Porto, Lucas R; Ip, Candice J X; Nantel, Megan K T; Tellkamp, Friedjof; Lu, Yinfei; Miller, R J Dwayne

    2015-08-01

    A simple method for the location and auto-alignment of sample fiducials for sample registration using widely available MATLAB/LabVIEW software is demonstrated. The method is robust, easily implemented, and applicable to a wide variety of experiment types for improved reproducibility and increased setup speed. The software uses image processing to locate and measure the diameter and center point of circular fiducials for distance self-calibration and iterative alignment and can be used with most imaging systems. The method is demonstrated to be fast and reliable in locating and aligning sample fiducials, provided here by a nanofabricated array, with accuracy within the optical resolution of the imaging system. The software was further demonstrated to register, load, and sample the dynamically wetted array.

  15. Testing Convergence of Different Free-Energy Methods in a Simple Analytical System with Hidden Barriers

    Directory of Open Access Journals (Sweden)

    S. Alexis Paz

    2018-03-01

    Full Text Available In this work, we study the influence of hidden barriers on the convergence behavior of three free-energy calculation methods: well-tempered metadynamics (WTMD, adaptive-biasing forces (ABF, and on-the-fly parameterization (OTFP. We construct a simple two-dimensional potential-energy surfaces (PES that allows for an exact analytical result for the free-energy in any one-dimensional order parameter. Then we chose different CV definitions and PES parameters to create three different systems with increasing sampling challenges. We find that all three methods are not greatly affected by the hidden-barriers in the simplest case considered. The adaptive sampling methods show faster sampling while the auxiliary high-friction requirement of OTFP makes it slower for this case. However, a slight change in the CV definition has a strong impact in the ABF and WTMD performance, illustrating the importance of choosing suitable collective variables.

  16. A simple orbit-attitude coupled modelling method for large solar power satellites

    Science.gov (United States)

    Li, Qingjun; Wang, Bo; Deng, Zichen; Ouyang, Huajiang; Wei, Yi

    2018-04-01

    A simple modelling method is proposed to study the orbit-attitude coupled dynamics of large solar power satellites based on natural coordinate formulation. The generalized coordinates are composed of Cartesian coordinates of two points and Cartesian components of two unitary vectors instead of Euler angles and angular velocities, which is the reason for its simplicity. Firstly, in order to develop natural coordinate formulation to take gravitational force and gravity gradient torque of a rigid body into account, Taylor series expansion is adopted to approximate the gravitational potential energy. The equations of motion are constructed through constrained Hamilton's equations. Then, an energy- and constraint-conserving algorithm is presented to solve the differential-algebraic equations. Finally, the proposed method is applied to simulate the orbit-attitude coupled dynamics and control of a large solar power satellite considering gravity gradient torque and solar radiation pressure. This method is also applicable to dynamic modelling of other rigid multibody aerospace systems.

  17. A novel and simple fabrication method of embedded SU-8 micro channels by direct UV lithography

    International Nuclear Information System (INIS)

    Fu, C; Hung, C; Huang, H

    2006-01-01

    In this paper, we presents a novel and simple method to fabricate embedded micro channels. The method based on different light absorption properties of the SU-8 thick photoresist under different incident UV wavelengths. The channel structures are defined by the ordinary I-line, while the cover layer is patterned by the deep UV. Because the deep UV is obtained directly on the same aligner with a set of filter mirrors, the embedded channel can be easily produced without other rare facilities. Besides, the relationship between the thickness of the top layer and the exposure dose of the deep UV has been measured by an ingeniously designed experiment. The specific thickness of the top layer of the embedded micro channel can then be secured by the specific deep-UV exposure dose. Further more, many meaningful mechanical structures have been realized by this method, the material property of the top layer are also measured

  18. A simple linear regression method for quantitative trait loci linkage analysis with censored observations.

    Science.gov (United States)

    Anderson, Carl A; McRae, Allan F; Visscher, Peter M

    2006-07-01

    Standard quantitative trait loci (QTL) mapping techniques commonly assume that the trait is both fully observed and normally distributed. When considering survival or age-at-onset traits these assumptions are often incorrect. Methods have been developed to map QTL for survival traits; however, they are both computationally intensive and not available in standard genome analysis software packages. We propose a grouped linear regression method for the analysis of continuous survival data. Using simulation we compare this method to both the Cox and Weibull proportional hazards models and a standard linear regression method that ignores censoring. The grouped linear regression method is of equivalent power to both the Cox and Weibull proportional hazards methods and is significantly better than the standard linear regression method when censored observations are present. The method is also robust to the proportion of censored individuals and the underlying distribution of the trait. On the basis of linear regression methodology, the grouped linear regression model is computationally simple and fast and can be implemented readily in freely available statistical software.

  19. A simple and efficient total genomic DNA extraction method for individual zooplankton.

    Science.gov (United States)

    Fazhan, Hanafiah; Waiho, Khor; Shahreza, Md Sheriff

    2016-01-01

    Molecular approaches are widely applied in species identification and taxonomic studies of minute zooplankton. One of the most focused zooplankton nowadays is from Subclass Copepoda. Accurate species identification of all life stages of the generally small sized copepods through molecular analysis is important, especially in taxonomic and systematic assessment of harpacticoid copepod populations and to understand their dynamics within the marine community. However, total genomic DNA (TGDNA) extraction from individual harpacticoid copepods can be problematic due to their small size and epibenthic behavior. In this research, six TGDNA extraction methods done on individual harpacticoid copepods were compared. The first new simple, feasible, efficient and consistent TGDNA extraction method was designed and compared with the commercial kit and modified available TGDNA extraction methods. The newly described TGDNA extraction method, "Incubation in PCR buffer" method, yielded good and consistent results based on the high success rate of PCR amplification (82%) compared to other methods. Coupled with its relatively consistent and economical method the "Incubation in PCR buffer" method is highly recommended in the TGDNA extraction of other minute zooplankton species.

  20. A Simple Method of Spectrum Processing for β-ray Measurement without Pretreatment

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Jun Woo; Kim, Hee Reyoung [UNIST, Ulsan (Korea, Republic of)

    2016-10-15

    Radioactivity analysis of β-emitting radionuclide is important because of its dangerousness of overexposure. γ-ray has been measured by conventional detector such as NaI(Tl) or high purity germanium (HPGe) detector. But β-ray is hard to detect by those detectors because of its short range. Therefore, liquid scintillation counter (LSC) has been used to measure the radioactivity of pure beta emitter but there is huge problem of organic waste production, though LSC has high efficiency for detection of low energy β-ray. To solve this problem, characterization of β-ray measurement in a plastic scintillator was carried out in this study. There have been some studies about plastic scintillator to measure the β-rays without liquid scintillation method. Plastic scintillator has benefits for detection of β-ray because it has relative low effective atomic number. β-ray and γ-ray spectra in cylindrical plastic scintillator was analyzed and a method of separation of β-ray spectrum was suggested. A simple method of β-ray spectrum separation was suggested. The method was verified by chi-square method to estimate the difference between calculated and measured spectrum. This method was successfully applied by using disc source. For future works, practical radioactive source will be used to acquire the pulse height spectrum. The method can be used for measurement of pure β emitter without pretreatment if this method is verified for practical purpose.

  1. Comparison of six simple methods for extracting ribosomal and mitochondrial DNA from Toxocara and Toxascaris nematodes.

    Science.gov (United States)

    Mikaeili, F; Kia, E B; Sharbatkhori, M; Sharifdini, M; Jalalizand, N; Heidari, Z; Zarei, Z; Stensvold, C R; Mirhendi, H

    2013-06-01

    Six simple methods for extraction of ribosomal and mitochondrial DNA from Toxocara canis, Toxocara cati and Toxascaris leonina were compared by evaluating the presence, appearance and intensity of PCR products visualized on agarose gels and amplified from DNA extracted by each of the methods. For each species, two isolates were obtained from the intestines of their respective hosts: T. canis and T. leonina from dogs, and T. cati from cats. For all isolates, total DNA was extracted using six different methods, including grinding, boiling, crushing, beating, freeze-thawing and the use of a commercial kit. To evaluate the efficacy of each method, the internal transcribed spacer (ITS) region and the cytochrome c oxidase subunit 1 (cox1) gene were chosen as representative markers for ribosomal and mitochondrial DNA, respectively. Among the six DNA extraction methods, the beating method was the most cost effective for all three species, followed by the commercial kit. Both methods produced high intensity bands on agarose gels and were characterized by no or minimal smear formation, depending on gene target; however, beating was less expensive. We therefore recommend the beating method for studies where costs need to be kept at low levels. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Evaluation of a cumulative SUV-volume histogram method for parameterizing heterogeneous intratumoural FDG uptake in non-small cell lung cancer PET studies

    Energy Technology Data Exchange (ETDEWEB)

    Velden, Floris H.P. van; Cheebsumon, Patsuree; Yaqub, Maqsood; Hoekstra, Otto S.; Lammertsma, Adriaan A.; Boellaard, Ronald [VU University Medical Center, Department of Nuclear Medicine and PET Research, PO Box 7057, Amsterdam (Netherlands); Smit, Egbert F. [VU University Medical Center, Department of Pulmonary Diseases, Amsterdam (Netherlands)

    2011-09-15

    Standardized uptake values (SUV) are commonly used for quantification of whole-body [{sup 18}F]fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) studies. Changes in SUV following therapy, however, only provide a proper measure of response in case of homogeneous FDG uptake in the tumour. The purpose of this study was therefore to implement and characterize a method that enables quantification of heterogeneity in tumour FDG uptake. Cumulative SUV-volume histograms (CSH), describing % of total tumour volume above % threshold of maximum SUV (SUV{sub max}), were calculated. The area under a CSH curve (AUC) is a quantitative index of tumour uptake heterogeneity, with lower AUC corresponding to higher degrees of heterogeneity. Simulations of homogeneous and heterogeneous responses were performed to assess the value of AUC-CSH for measuring uptake and/or response heterogeneity. In addition, partial volume correction and image denoising was applied prior to calculating AUC-CSH. Finally, the method was applied to a number of human FDG scans. Partial volume correction and noise reduction improved CSH curves. Both simulations and clinical examples showed that AUC-CSH values corresponded with level of tumour heterogeneity and/or heterogeneity in response. In contrast, this correspondence was not seen with SUV{sub max} alone. The results indicate that the main advantage of AUC-CSH above other measures, such as 1/COV (coefficient of variation), is the possibility to measure or normalize AUC-CSH in different ways. AUC-CSH might be used as a quantitative index of heterogeneity in tracer uptake. In response monitoring studies it can be used to address heterogeneity in response. (orig.)

  3. Evaluation of a cumulative SUV-volume histogram method for parameterizing heterogeneous intratumoural FDG uptake in non-small cell lung cancer PET studies

    International Nuclear Information System (INIS)

    Velden, Floris H.P. van; Cheebsumon, Patsuree; Yaqub, Maqsood; Hoekstra, Otto S.; Lammertsma, Adriaan A.; Boellaard, Ronald; Smit, Egbert F.

    2011-01-01

    Standardized uptake values (SUV) are commonly used for quantification of whole-body [ 18 F]fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) studies. Changes in SUV following therapy, however, only provide a proper measure of response in case of homogeneous FDG uptake in the tumour. The purpose of this study was therefore to implement and characterize a method that enables quantification of heterogeneity in tumour FDG uptake. Cumulative SUV-volume histograms (CSH), describing % of total tumour volume above % threshold of maximum SUV (SUV max ), were calculated. The area under a CSH curve (AUC) is a quantitative index of tumour uptake heterogeneity, with lower AUC corresponding to higher degrees of heterogeneity. Simulations of homogeneous and heterogeneous responses were performed to assess the value of AUC-CSH for measuring uptake and/or response heterogeneity. In addition, partial volume correction and image denoising was applied prior to calculating AUC-CSH. Finally, the method was applied to a number of human FDG scans. Partial volume correction and noise reduction improved CSH curves. Both simulations and clinical examples showed that AUC-CSH values corresponded with level of tumour heterogeneity and/or heterogeneity in response. In contrast, this correspondence was not seen with SUV max alone. The results indicate that the main advantage of AUC-CSH above other measures, such as 1/COV (coefficient of variation), is the possibility to measure or normalize AUC-CSH in different ways. AUC-CSH might be used as a quantitative index of heterogeneity in tracer uptake. In response monitoring studies it can be used to address heterogeneity in response. (orig.)

  4. A simple method of genomic DNA extraction suitable for analysis of bulk fungal strains.

    Science.gov (United States)

    Zhang, Y J; Zhang, S; Liu, X Z; Wen, H A; Wang, M

    2010-07-01

    A simple and rapid method (designated thermolysis) for extracting genomic DNA from bulk fungal strains was described. In the thermolysis method, a few mycelia or yeast cells were first rinsed with pure water to remove potential PCR inhibitors and then incubated in a lysis buffer at 85 degrees C to break down cell walls and membranes. This method was used to extract genomic DNA from large numbers of fungal strains (more than 92 species, 35 genera of three phyla) isolated from different sections of natural Ophiocordyceps sinensis specimens. Regions of interest from high as well as single-copy number genes were successfully amplified from the extracted DNA samples. The DNA samples obtained by this method can be stored at -20 degrees C for over 1 year. The method was effective, easy and fast and allowed batch DNA extraction from multiple fungal isolates. Use of the thermolysis method will allow researchers to obtain DNA from fungi quickly for use in molecular assays. This method requires only minute quantities of starting material and is suitable for diverse fungal species.

  5. Comparison of simple additive weighting (SAW) and composite performance index (CPI) methods in employee remuneration determination

    Science.gov (United States)

    Karlitasari, L.; Suhartini, D.; Benny

    2017-01-01

    The process of determining the employee remuneration for PT Sepatu Mas Idaman currently are still using Microsoft Excel-based spreadsheet where in the spreadsheet there is the value of criterias that must be calculated for every employee. This can give the effect of doubt during the assesment process, therefore resulting in the process to take much longer time. The process of employee remuneration determination is conducted by the assesment team based on some criterias that have been predetermined. The criteria used in the assessment process are namely the ability to work, human relations, job responsibility, discipline, creativity, work, achievement of targets, and absence. To ease the determination of employee remuneration to be more efficient and effective, the Simple Additive Weighting (SAW) method is used. SAW method can help in decision making for a certain case, and the calculation that generates the greatest value will be chosen as the best alternative. Other than SAW, also by using another method was the CPI method which is one of the calculating method in decision making based on performance index. Where SAW method was more faster by 89-93% compared to CPI method. Therefore it is expected that this application can be an evaluation material for the need of training and development for employee performances to be more optimal.

  6. A simple gamma spectrometry method for evaluating the burnup of MTR-type HEU fuel elements

    Energy Technology Data Exchange (ETDEWEB)

    Makmal, T. [The Unit of Nuclear Engineering, Ben-Gurion University of The Negev, Beer-Sheva 84105 (Israel); Nuclear Physics and Engineering Division, Soreq Nuclear Research Center, Yavne 81800 (Israel); Aviv, O. [Radiation Safety Division, Soreq Nuclear Research Center, Yavne 81800 (Israel); Gilad, E., E-mail: gilade@bgu.ac.il [The Unit of Nuclear Engineering, Ben-Gurion University of The Negev, Beer-Sheva 84105 (Israel)

    2016-10-21

    A simple method for the evaluation of the burnup of a materials testing reactor (MTR) fuel element by gamma spectrometry is presented. The method was applied to a highly enriched uranium MTR nuclear fuel element that was irradiated in a 5 MW pool-type research reactor for a total period of 34 years. The experimental approach is based on in-situ measurements of the MTR fuel element in the reactor pool by a portable high-purity germanium detector located in a gamma cell. To corroborate the method, analytical calculations (based on the irradiation history of the fuel element) and computer simulations using a dedicated fuel cycle burnup code ORIGEN2 were performed. The burnup of the MTR fuel element was found to be 52.4±8.8%, which is in good agreement with the analytical calculations and the computer simulations. The method presented here is suitable for research reactors with either a regular or an irregular irradiation regime and for reactors with limited infrastructure and/or resources. In addition, its simplicity and the enhanced safety it confers may render this method suitable for IAEA inspectors in fuel element burnup assessments during on-site inspections. - Highlights: • Simple, inexpensive, safe and flexible experimental setup that can be quickly deployed. • Experimental results are thoroughly corroborated against ORIGEN2 burnup code. • Experimental uncertainty of 9% and 5% deviation between measurements and simulations. • Very high burnup MTR fuel element is examined, with 60% depletion of {sup 235}U. • Impact of highly irregular irradiation regime on burnup evaluation is studied.

  7. Filtration Isolation of Nucleic Acids: A Simple and Rapid DNA Extraction Method.

    Science.gov (United States)

    McFall, Sally M; Neto, Mário F; Reed, Jennifer L; Wagner, Robin L

    2016-08-06

    FINA, filtration isolation of nucleic acids, is a novel extraction method which utilizes vertical filtration via a separation membrane and absorbent pad to extract cellular DNA from whole blood in less than 2 min. The blood specimen is treated with detergent, mixed briefly and applied by pipet to the separation membrane. The lysate wicks into the blotting pad due to capillary action, capturing the genomic DNA on the surface of the separation membrane. The extracted DNA is retained on the membrane during a simple wash step wherein PCR inhibitors are wicked into the absorbent blotting pad. The membrane containing the entrapped DNA is then added to the PCR reaction without further purification. This simple method does not require laboratory equipment and can be easily implemented with inexpensive laboratory supplies. Here we describe a protocol for highly sensitive detection and quantitation of HIV-1 proviral DNA from 100 µl whole blood as a model for early infant diagnosis of HIV that could readily be adapted to other genetic targets.

  8. A Simple Transmission Electron Microscopy Method for Fast Thickness Characterization of Suspended Graphene and Graphite Flakes.

    Science.gov (United States)

    Rubino, Stefano; Akhtar, Sultan; Leifer, Klaus

    2016-02-01

    We present a simple, fast method for thickness characterization of suspended graphene/graphite flakes that is based on transmission electron microscopy (TEM). We derive an analytical expression for the intensity of the transmitted electron beam I 0(t), as a function of the specimen thickness t (tgraphite). We show that in thin graphite crystals the transmitted intensity is a linear function of t. Furthermore, high-resolution (HR) TEM simulations are performed to obtain λ for a 001 zone axis orientation, in a two-beam case and in a low symmetry orientation. Subsequently, HR (used to determine t) and bright-field (to measure I 0(0) and I 0(t)) images were acquired to experimentally determine λ. The experimental value measured in low symmetry orientation matches the calculated value (i.e., λ=225±9 nm). The simulations also show that the linear approximation is valid up to a sample thickness of 3-4 nm regardless of the orientation and up to several ten nanometers for a low symmetry orientation. When compared with standard techniques for thickness determination of graphene/graphite, the method we propose has the advantage of being simple and fast, requiring only the acquisition of bright-field images.

  9. Slope stability and bearing capacity of landfills and simple on-site test methods.

    Science.gov (United States)

    Yamawaki, Atsushi; Doi, Yoichi; Omine, Kiyoshi

    2017-07-01

    This study discusses strength characteristics (slope stability, bearing capacity, etc.) of waste landfills through on-site tests that were carried out at 29 locations in 19 sites in Japan and three other countries, and proposes simple methods to test and assess the mechanical strength of landfills on site. Also, the possibility of using a landfill site was investigated by a full-scale eccentric loading test. As a result of this, landfills containing more than about 10 cm long plastics or other fibrous materials were found to be resilient and hard to yield. An on-site full scale test proved that no differential settlement occurs. The repose angle test proposed as a simple on-site test method has been confirmed to be a good indicator for slope stability assessment. The repose angle test suggested that landfills which have high, near-saturation water content have considerably poorer slope stability. The results of our repose angle test and the impact acceleration test were related to the internal friction angle and the cohesion, respectively. In addition to this, it was found that the air pore volume ratio measured by an on-site air pore volume ratio test is likely to be related to various strength parameters.

  10. Bubble nucleation in simple and molecular liquids via the largest spherical cavity method

    International Nuclear Information System (INIS)

    Gonzalez, Miguel A.; Abascal, José L. F.; Valeriani, Chantal; Bresme, Fernando

    2015-01-01

    In this work, we propose a methodology to compute bubble nucleation free energy barriers using trajectories generated via molecular dynamics simulations. We follow the bubble nucleation process by means of a local order parameter, defined by the volume of the largest spherical cavity (LSC) formed in the nucleating trajectories. This order parameter simplifies considerably the monitoring of the nucleation events, as compared with the previous approaches which require ad hoc criteria to classify the atoms and molecules as liquid or vapor. The combination of the LSC and the mean first passage time technique can then be used to obtain the free energy curves. Upon computation of the cavity distribution function the nucleation rate and free-energy barrier can then be computed. We test our method against recent computations of bubble nucleation in simple liquids and water at negative pressures. We obtain free-energy barriers in good agreement with the previous works. The LSC method provides a versatile and computationally efficient route to estimate the volume of critical bubbles the nucleation rate and to compute bubble nucleation free-energies in both simple and molecular liquids

  11. Use of eddy-covariance methods to "calibrate" simple estimators of evapotranspiration

    Science.gov (United States)

    Sumner, David M.; Geurink, Jeffrey S.; Swancar, Amy

    2017-01-01

    Direct measurement of actual evapotranspiration (ET) provides quantification of this large component of the hydrologic budget, but typically requires long periods of record and large instrumentation and labor costs. Simple surrogate methods of estimating ET, if “calibrated” to direct measurements of ET, provide a reliable means to quantify ET. Eddy-covariance measurements of ET were made for 12 years (2004-2015) at an unimproved bahiagrass (Paspalum notatum) pasture in Florida. These measurements were compared to annual rainfall derived from rain gage data and monthly potential ET (PET) obtained from a long-term (since 1995) U.S. Geological Survey (USGS) statewide, 2-kilometer, daily PET product. The annual proportion of ET to rainfall indicates a strong correlation (r2=0.86) to annual rainfall; the ratio increases linearly with decreasing rainfall. Monthly ET rates correlated closely (r2=0.84) to the USGS PET product. The results indicate that simple surrogate methods of estimating actual ET show positive potential in the humid Florida climate given the ready availability of historical rainfall and PET.

  12. Theoretical comparison of performance using transfer functions for reactivity meters based on inverse kinetic method and simple feedback method

    International Nuclear Information System (INIS)

    Shimazu, Yoichiro; Tashiro, Shoichi; Tojo, Masayuki

    2017-01-01

    The performance of two digital reactivity meters, one based on the conventional inverse kinetic method and the other one based on simple feedback theory, are compared analytically using their respective transfer functions. The latter one is proposed by one of the authors. It has been shown that the performance of the two reactivity meters become almost identical when proper system parameters are selected for each reactivity meter. A new correlation between the system parameters of the two reactivity meters is found. With this correlation, filter designers can easily determine the system parameters for the respective reactivity meters to obtain identical performance. (author)

  13. Development of a novel and simple method to evaluate disintegration of rapidly disintegrating tablets.

    Science.gov (United States)

    Hoashi, Yohei; Tozuka, Yuichi; Takeuchi, Hirofumi

    2013-01-01

    The purpose of this study was to develop and test a novel and simple method for evaluating the disintegration time of rapidly disintegrating tablets (RDTs) in vitro, since the conventional disintegration test described in the pharmacopoeia produces poor results due to the difference of its environmental conditions from those of an actual oral cavity. Six RDTs prepared in our laboratory and 5 types of commercial RDTs were used as model formulations. Using our original apparatus, a good correlation was observed between in vivo and in vitro disintegration times by adjusting the height from which the solution was dropped to 8 cm and the weight of the load to 10 or 20 g. Properties of RDTs, such as the pattern of their disintegrating process, can be assessed by verifying the load. These findings confirmed that our proposed method for an in vitro disintegration test apparatus is an excellent one for estimating disintegration time and the disintegration profile of RDTs.

  14. A simple and effective method for construction of Escherichia coli strains proficient for genome engineering.

    Directory of Open Access Journals (Sweden)

    Young Shin Ryu

    Full Text Available Multiplex genome engineering is a standalone recombineering tool for large-scale programming and accelerated evolution of cells. However, this advanced genome engineering technique has been limited to use in selected bacterial strains. We developed a simple and effective strain-independent method for effective genome engineering in Escherichia coli. The method involves introducing a suicide plasmid carrying the λ Red recombination system into the mutS gene. The suicide plasmid can be excised from the chromosome via selection in the absence of antibiotics, thus allowing transient inactivation of the mismatch repair system during genome engineering. In addition, we developed another suicide plasmid that enables integration of large DNA fragments into the lacZ genomic locus. These features enable this system to be applied in the exploitation of the benefits of genome engineering in synthetic biology, as well as the metabolic engineering of different strains of E. coli.

  15. Simple estimating method of damages of concrete gravity dam based on linear dynamic analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, T.; Kanenawa, K.; Yamaguchi, Y. [Public Works Research Institute, Tsukuba, Ibaraki (Japan). Hydraulic Engineering Research Group

    2004-07-01

    Due to the occurrence of large earthquakes like the Kobe Earthquake in 1995, there is a strong need to verify seismic resistance of dams against much larger earthquake motions than those considered in the present design standard in Japan. Problems exist in using nonlinear analysis to evaluate the safety of dams including: that the influence which the set material properties have on the results of nonlinear analysis is large, and that the results of nonlinear analysis differ greatly according to the damage estimation models or analysis programs. This paper reports the evaluation indices based on a linear dynamic analysis method and the characteristics of the progress of cracks in concrete gravity dams with different shapes using a nonlinear dynamic analysis method. The study concludes that if simple linear dynamic analysis is appropriately conducted to estimate tensile stress at potential locations of initiating cracks, the damage due to cracks would be predicted roughly. 4 refs., 1 tab., 13 figs.

  16. A simple identification method for spore-forming bacteria showing high resistance against γ-rays

    International Nuclear Information System (INIS)

    Koshikawa, Tomihiko; Sone, Koji; Kobayashi, Toshikazu

    1993-01-01

    A simple identification method was developed for spore-forming bacteria which are highly resistant against γ-rays. Among 23 species of Bacillus studied, the spores of Bacillus megaterium, B. cereus, B. thuringiensis, B. pumilus and B. aneurinolyticus showed high resistance against γ-rays as compared with other spores of Bacillus species. Combination of the seven kinds of biochemical tests, namely, the citrate utilization test, nitrate reduction test, starch hydrolysis test, Voges-Proskauer reaction test, gelatine hydrolysis test, mannitol utilization test and xylose utilization test showed a characteristic pattern for each species of Bacillus. The combination pattern of each the above tests with a few supplementary test, if necessary, was useful to identify Bacillus species showing high radiation resistance against γ-rays. The method is specific for B. megaterium, B. thuringiensis and B. pumilus, and highly selective for B. aneurinolyticus and B. cereus. (author)

  17. A Simple and Clean Method for O-Isopropylidenation of Carbohydrates

    Energy Technology Data Exchange (ETDEWEB)

    Rong, Yuan Wei; Zhang, Qi Hua; Wang, Wei; Li, Bao Lin [Shaanxi Normal Univ., Xi' an (China)

    2014-07-15

    An efficient catalysis system for the synthesis of O-isopropylidene derivatives of sugars and polyhydroxy alcohols has been developed with sulfonated polystyrene cation exchange resin CAT600 as a catalyst. The key advantages of this protocol are simple workup, good yields and the recoverability, the innocuity and low cost of the catalyst. As a green, general and efficient reaction system, this method is expected to attract much attention for the preparation of various O-isopropylidene sugar derivatives in a large scale. Protection of hydroxyl functions by O-isopropylidenation is an important method in the field of carbohydrate chemistry. Due to its convenient application in synthetic, configurational and conformational studies, the O-isopropylidene derivatives of sugars play an important role in the research of building blocks, such as glycosyl acceptors and glycosyl donors. Additionally, these derivatives of sugars are important in the synthesis of various natural products.

  18. Simple formulae for interpretation of the dead time α (first moment) method of reactor noise

    International Nuclear Information System (INIS)

    Degweker, S.B.

    1999-01-01

    The Markov Chain approach for solving problems related to the presence of a non extending dead time in a particle counting circuit with time correlated pulses was developed in an earlier paper. The formalism was applied to, among others, the dead time α (first moment) method of reactor noise. For this problem, however the solution obtained was largely numerical in character and had a tendency to break down for systems close to criticality. In the present paper, simple analytical expressions are derived for the count rate and L ex , the quantities of interest in this method. Comparisons with Monte Carlo simulations show that these formulae are accurate in the range of system parameters of practical interest

  19. Simple saponification method for the quantitative determination of carotenoids in green vegetables.

    Science.gov (United States)

    Larsen, Erik; Christensen, Lars P

    2005-08-24

    A simple, reliable, and gentle saponification method for the quantitative determination of carotenoids in green vegetables was developed. The method involves an extraction procedure with acetone and the selective removal of the chlorophylls and esterified fatty acids from the organic phase using a strongly basic resin (Ambersep 900 OH). Extracts from common green vegetables (beans, broccoli, green bell pepper, chive, lettuce, parsley, peas, and spinach) were analyzed by high-performance liquid chromatography (HPLC) for their content of major carotenoids before and after action of Ambersep 900 OH. The mean recovery percentages for most carotenoids [(all-E)-violaxanthin, (all-E)-lutein epoxide, (all-E)-lutein, neolutein A, and (all-E)-beta-carotene] after saponification of the vegetable extracts with Ambersep 900 OH were close to 100% (99-104%), while the mean recovery percentages of (9'Z)-neoxanthin increased to 119% and that of (all-E)-neoxanthin and neolutein B decreased to 90% and 72%, respectively.

  20. A Simple Halide-to-Anion Exchange Method for Heteroaromatic Salts and Ionic Liquids

    Directory of Open Access Journals (Sweden)

    Neus Mesquida

    2012-04-01

    Full Text Available A broad and simple method permitted halide ions in quaternary heteroaromatic and ammonium salts to be exchanged for a variety of anions using an anion exchange resin (A− form in non-aqueous media. The anion loading of the AER (OH− form was examined using two different anion sources, acids or ammonium salts, and changing the polarity of the solvents. The AER (A− form method in organic solvents was then applied to several quaternary heteroaromatic salts and ILs, and the anion exchange proceeded in excellent to quantitative yields, concomitantly removing halide impurities. Relying on the hydrophobicity of the targeted ion pair for the counteranion swap, organic solvents with variable polarity were used, such as CH3OH, CH3CN and the dipolar nonhydroxylic solvent mixture CH3CN:CH2Cl2 (3:7 and the anion exchange was equally successful with both lipophilic cations and anions.

  1. Simple method based on intensity measurements for characterization of aberrations from micro-optical components.

    Science.gov (United States)

    Perrin, Stephane; Baranski, Maciej; Froehly, Luc; Albero, Jorge; Passilly, Nicolas; Gorecki, Christophe

    2015-11-01

    We report a simple method, based on intensity measurements, for the characterization of the wavefront and aberrations produced by micro-optical focusing elements. This method employs the setup presented earlier in [Opt. Express 22, 13202 (2014)] for measurements of the 3D point spread function, on which a basic phase-retrieval algorithm is applied. This combination allows for retrieval of the wavefront generated by the micro-optical element and, in addition, quantification of the optical aberrations through the wavefront decomposition with Zernike polynomials. The optical setup requires only an in-motion imaging system. The technique, adapted for the optimization of micro-optical component fabrication, is demonstrated by characterizing a planoconvex microlens.

  2. A simple method employed for the treatment of filters used in atmospheric pollution studies

    International Nuclear Information System (INIS)

    Prendez B, M.M.; Ortiz C, J.L.; Garrido, J.I.; Huerta P, R.; Alvarez B, C.; Zolezzi C, S.R.

    1983-01-01

    A simple and rapid method for the multielement routine analysis of atmospheric particulate matter is described. The samples collected on four different types of filters were treated with HNO 3 and HCl at 110-120 deg C in pyrex glassware. Time required for the different stages of the treatment was determined by using 60 Co, 65 Zn and 137 Cs as radioactive tracers. Atomic absorption spectrophotometry was used to determine the concentration of the elements. The efficiency for 11 elements (Mg, Cr, Mn, Fe, Co, Ni, Cu, Zn, Cd, Hg and Pb) was determined. The method was succesfully employed for the treatment of filters used in atmospheric pollution studies in both urban and rural areas. (author)

  3. Application of a simple parameter estimation method to predict effluent transport in the Savannah River

    International Nuclear Information System (INIS)

    Hensel, S.J.; Hayes, D.W.

    1993-01-01

    A simple parameter estimation method has been developed to determine the dispersion and velocity parameters associated with stream/river transport. The unsteady one dimensional Burgers' equation was chosen as the model equation, and the method has been applied to recent Savannah River dye tracer studies. The computed Savannah River transport coefficients compare favorably with documented values, and the time/concentration curves calculated from these coefficients compare well with the actual tracer data. The coefficients were used as a predictive capability and applied to Savannah River tritium concentration data obtained during the December 1991 accidental tritium discharge from the Savannah River Site. The peak tritium concentration at the intersection of Highway 301 and the Savannah River was underpredicted by only 5% using the coefficients computed from the dye data

  4. A simple method for principal strata effects when the outcome has been truncated due to death.

    Science.gov (United States)

    Chiba, Yasutaka; VanderWeele, Tyler J

    2011-04-01

    In randomized trials with follow-up, outcomes such as quality of life may be undefined for individuals who die before the follow-up is complete. In such settings, restricting analysis to those who survive can give rise to biased outcome comparisons. An alternative approach is to consider the "principal strata effect" or "survivor average causal effect" (SACE), defined as the effect of treatment on the outcome among the subpopulation that would have survived under either treatment arm. The authors describe a very simple technique that can be used to assess the SACE. They give both a sensitivity analysis technique and conditions under which a crude comparison provides a conservative estimate of the SACE. The method is illustrated using data from the ARDSnet (Acute Respiratory Distress Syndrome Network) clinical trial comparing low-volume ventilation and traditional ventilation methods for individuals with acute respiratory distress syndrome.

  5. A simple method to measure cell viability in proliferation and cytotoxicity assays

    Directory of Open Access Journals (Sweden)

    Ricardo Carneiro Borra

    2009-09-01

    Full Text Available Resazurin dye has been broadly used as indicator of cell viability in several types of assays for evaluation of the biocompatibility of medical and dental materials. Mitochondrial enzymes, as carriers of diaphorase activities, are probably responsible for the transference of electrons from NADPH + H+ to resazurin, which is reduced to resorufin. The level of reduction can be quantified by spectrophotometers since resazurin exhibits an absorption peak at 600 ηm and resorufin at 570 ηm wavelengths. However, the requirement of a spectrophotometer and specific filters for the quantification could be a barrier to many laboratories. Digital cameras containing red, green and blue filters, which allow the capture of red (600 to 700 ηm and green (500 to 600 ηm light wavelengths in ranges bordering on resazurin and resorufin absorption bands, could be used as an alternative method for the assessment of resazurin and resorufin concentrations. Thus, our aim was to develop a simple, cheap and precise method based on a digital CCD camera to measure the reduction of resazurin. We compared the capability of the CCD-based method to distinguish different concentrations of L929 and normal Human buccal fibroblast cell lines with that of a conventional microplate reader. The correlation was analyzed through the Pearson coefficient. The results showed a strong association between the measurements of the method developed here and those made with the microplate reader (r² = 0.996; p < 0.01 and with the cellular concentrations (r² = 0.965; p < 0.01. We concluded that the developed Colorimetric Quantification System based on CCD Images allowed rapid assessment of the cultured cell concentrations with simple equipment at a reduced cost.

  6. The simple method to co-register planar image with photograph

    International Nuclear Information System (INIS)

    Jang, Sung June; Kim, Seok Ki; Kang, Keon Wook

    2005-01-01

    Generally scintigraphic image presents the highly specific functional information. Sometimes, there can be limited information of patients anatomical landmark required to identify the lesion in planar nuclear medicine image. In this study, we applied the simple fusion method of planar scintigraphy and plain photography and validated the techniques with our own software. We used three fiducial marks which were comprised with Tc-99m. We obtained planar image with single head gamma camera (ARGUS ADAC laboratory, USA) and photograph using a general digital camera (CANON JAPAN). The coordinates of three marks were obtained in photograph and planar scintigraphy image. Based on these points, we took affine transformation and then fused these two images. To evaluate the precision, we compared with different depth. To find out the depth of lesion, the images were acquired in different angles and we compared the real depth and the geometrically calculated depth. At the same depth with mark, the each discordance was less than 1 mm. When the photograph were taken at the distance with 1 m and 2 m, the point 30 cm off the center were discordant in 5 mm and 2 mm each. We used this method in the localization of the remnant thyroid tissue on I-131 whole body scan with photo image. The simple method to co-register planar image with photography was reliable and easy to use. By this method, we could localize the lesion on the planar scintigraphy more accurately with other planar images (i.e. photograph) and predict the depth of the lesion without tomographic image

  7. A Simple Method for Closure of Urethrocutaneous Fistula after Tubularized Incised Plate Repair: Preliminary Results.

    Science.gov (United States)

    Shirazi, Mehdi; Ariafar, Ali; Babaei, Amir Hossein; Ashrafzadeh, Abdosamad; Adib, Ali

    2016-11-01

    Urethrocutaneous fistula (UCF) is the most prevalent complication after hypospadias repair surgery. Many methods have been developed for UCF correction, and the best technique for UCF repair is determined based on the size, location, and number of fistulas, as well as the status of the surrounding skin. In this study, we introduced and evaluated a simple method for UCF correction after tubularized incised plate (TIP) repair. This clinical study was conducted on children with UCFs ≤ 4 mm that developed after TIP surgery for hypospadias repair. The skin was incised around the fistula and the tract was released from the surrounding tissues and the dartos fascia, then ligated with 5 - 0 polydioxanone (PDS) sutures. The dartos fascia, as the second layer, was covered on the fistula tract with PDS thread (gauge 5 - 0) by the continuous suture method. The skin was closed with 6 - 0 Vicryl sutures. After six months of follow-up, surgical outcomes were evaluated based on fistula relapse and other complications. After six months, relapse occurred in only one patient, a six-year-old boy with a single 4-mm distal opening, who had undergone no previous fistula repairs. Therefore, in 97.5% of the cases, relapse was non-existent. Other complications, such as urethral stenosis, intraurethral obstruction, and epidermal inclusion cysts, were not seen in the other patients during the six-month follow-up period. This repair method, which is simple, rapid, and easily learned, is highly applicable, with a high success rate for the closure of UCFs measuring up to 4 mm in any location.

  8. Validation of a simple and inexpensive method for the quantitation of infarct in the rat brain

    Directory of Open Access Journals (Sweden)

    C.L.R. Schilichting

    2004-04-01

    Full Text Available A gravimetric method was evaluated as a simple, sensitive, reproducible, low-cost alternative to quantify the extent of brain infarct after occlusion of the medial cerebral artery in rats. In ether-anesthetized rats, the left medial cerebral artery was occluded for 1, 1.5 or 2 h by inserting a 4-0 nylon monofilament suture into the internal carotid artery. Twenty-four hours later, the brains were processed for histochemical triphenyltetrazolium chloride (TTC staining and quantitation of the schemic infarct. In each TTC-stained brain section, the ischemic tissue was dissected with a scalpel and fixed in 10% formalin at 0ºC until its total mass could be estimated. The mass (mg of the ischemic tissue was weighed on an analytical balance and compared to its volume (mm³, estimated either by plethysmometry using platinum electrodes or by computer-assisted image analysis. Infarct size as measured by the weighing method (mg, and reported as a percent (% of the affected (left hemisphere, correlated closely with volume (mm³, also reported as % estimated by computerized image analysis (r = 0.88; P < 0.001; N = 10 or by plethysmography (r = 0.97-0.98; P < 0.0001; N = 41. This degree of correlation was maintained between different experimenters. The method was also sensitive for detecting the effect of different ischemia durations on infarct size (P < 0.005; N = 23, and the effect of drug treatments in reducing the extent of brain damage (P < 0.005; N = 24. The data suggest that, in addition to being simple and low cost, the weighing method is a reliable alternative for quantifying brain infarct in animal models of stroke.

  9. The proportional odds cumulative incidence model for competing risks

    DEFF Research Database (Denmark)

    Eriksson, Frank; Li, Jianing; Scheike, Thomas

    2015-01-01

    We suggest an estimator for the proportional odds cumulative incidence model for competing risks data. The key advantage of this model is that the regression parameters have the simple and useful odds ratio interpretation. The model has been considered by many authors, but it is rarely used...... in practice due to the lack of reliable estimation procedures. We suggest such procedures and show that their performance improve considerably on existing methods. We also suggest a goodness-of-fit test for the proportional odds assumption. We derive the large sample properties and provide estimators...

  10. Simple tool for the rapid, automated quantification of glacier advance/retreat observations using multiple methods

    Science.gov (United States)

    Lea, J.

    2017-12-01

    The quantification of glacier change is a key variable within glacier monitoring, with the method used potentially being crucial to ensuring that data can be appropriately compared with environmental data. The topic and timescales of study (e.g. land/marine terminating environments; sub-annual/decadal/centennial/millennial timescales) often mean that different methods are more suitable for different problems. However, depending on the GIS/coding expertise of the user, some methods can potentially be time consuming to undertake, making large-scale studies problematic. In addition, examples exist where different users have nominally applied the same methods in different studies, though with minor methodological inconsistencies in their approach. In turn, this will have implications for data homogeneity where regional/global datasets may be constructed. Here, I present a simple toolbox scripted in a Matlab® environment that requires only glacier margin and glacier centreline data to quantify glacier length, glacier change between observations, rate of change, in addition to other metrics. The toolbox includes the option to apply the established centreline or curvilinear box methods, or a new method: the variable box method - designed for tidewater margins where box width is defined as the total width of the individual terminus observation. The toolbox is extremely flexible, and has the option to be applied as either Matlab® functions within user scripts, or via a graphical user interface (GUI) for those unfamiliar with a coding environment. In both instances, there is potential to apply the methods quickly to large datasets (100s-1000s of glaciers, with potentially similar numbers of observations each), thus ensuring large scale methodological consistency (and therefore data homogeneity) and allowing regional/global scale analyses to be achievable for those with limited GIS/coding experience. The toolbox has been evaluated against idealised scenarios demonstrating

  11. The BUME method: a new rapid and simple chloroform-free method for total lipid extraction of animal tissue.

    Science.gov (United States)

    Löfgren, Lars; Forsberg, Gun-Britt; Ståhlman, Marcus

    2016-06-10

    In this study we present a simple and rapid method for tissue lipid extraction. Snap-frozen tissue (15-150 mg) is collected in 2 ml homogenization tubes. 500 μl BUME mixture (butanol:methanol [3:1]) is added and automated homogenization of up to 24 frozen samples at a time in less than 60 seconds is performed, followed by a 5-minute single-phase extraction. After the addition of 500 μl heptane:ethyl acetate (3:1) and 500 μl 1% acetic acid a 5-minute two-phase extraction is performed. Lipids are recovered from the upper phase by automated liquid handling using a standard 96-tip robot. A second two-phase extraction is performed using 500 μl heptane:ethyl acetate (3:1). Validation of the method showed that the extraction recoveries for the investigated lipids, which included sterols, glycerolipids, glycerophospholipids and sphingolipids were similar or better than for the Folch method. We also applied the method for lipid extraction of liver and heart and compared the lipid species profiles with profiles generated after Folch and MTBE extraction. We conclude that the BUME method is superior to the Folch method in terms of simplicity, through-put, automation, solvent consumption, economy, health and environment yet delivering lipid recoveries fully comparable to or better than the Folch method.

  12. The BUME method: a new rapid and simple chloroform-free method for total lipid extraction of animal tissue

    Science.gov (United States)

    Löfgren, Lars; Forsberg, Gun-Britt; Ståhlman, Marcus

    2016-06-01

    In this study we present a simple and rapid method for tissue lipid extraction. Snap-frozen tissue (15-150 mg) is collected in 2 ml homogenization tubes. 500 μl BUME mixture (butanol:methanol [3:1]) is added and automated homogenization of up to 24 frozen samples at a time in less than 60 seconds is performed, followed by a 5-minute single-phase extraction. After the addition of 500 μl heptane:ethyl acetate (3:1) and 500 μl 1% acetic acid a 5-minute two-phase extraction is performed. Lipids are recovered from the upper phase by automated liquid handling using a standard 96-tip robot. A second two-phase extraction is performed using 500 μl heptane:ethyl acetate (3:1). Validation of the method showed that the extraction recoveries for the investigated lipids, which included sterols, glycerolipids, glycerophospholipids and sphingolipids were similar or better than for the Folch method. We also applied the method for lipid extraction of liver and heart and compared the lipid species profiles with profiles generated after Folch and MTBE extraction. We conclude that the BUME method is superior to the Folch method in terms of simplicity, through-put, automation, solvent consumption, economy, health and environment yet delivering lipid recoveries fully comparable to or better than the Folch method.

  13. A simple method of evaluating non-isothermal crystallization kinetics in multicomponent polymer systems

    Czech Academy of Sciences Publication Activity Database

    Kratochvíl, Jaroslav; Kelnar, Ivan

    2015-01-01

    Roč. 47, October (2015), s. 79-86 ISSN 0142-9418 R&D Projects: GA ČR(CZ) GA13-15255S Institutional support: RVO:61389013 Keywords : non-isothermal crystallization kinetics * cumulative curves * inflection point Subject RIV: JI - Composite Materials Impact factor: 2.350, year: 2015

  14. Fast and simple method for semiquantitative determination of calcium propionate in bread samples

    Directory of Open Access Journals (Sweden)

    Chutima Matayatsuk Phechkrajang

    2017-04-01

    Full Text Available Calcium propionate has been widely used as a preservative in bakery and in bread. It is sometimes not carefully used, or a high concentration is added to preserve products. High consumption of calcium propionate can lead to several health problems. This study aims to develop a fast and simple semiquantitative method based on color complex formation for the determination of calcium propionate in a bread sample. A red–brown complex was obtained from the reaction of ferric ammonium sulfate and propionate anion. The product was rapidly formed and easily observed with the concentration of propionate anion >0.4 mg/mL. A high-performance liquid chromatography (HPLC method was also developed and validated for comparison. Twenty-two bread samples from three markets near Bangkok were randomly selected and assayed for calcium propionate using the above two developed methods. The results showed that 19/22 samples contained calcium propionate >2000 mg/kg. The results of the complex formation method agreed with the HPLC method.

  15. A Simple and Effective Isocratic HPLC Method for Fast Identification and Quantification of Surfactin

    International Nuclear Information System (INIS)

    Muhammad Qadri Effendy Mubarak; Abdul Rahman Hassan; Aidil Abdul Hamid; Sahaid Khalil; Mohd Hafez Mohd Isa

    2015-01-01

    The aim of this study was to establish a simple, accurate and reproducible method for the identification and quantification of surfactin using high-performance liquid chromatography (HPLC). Previously reported method of identification and quantification of surfactin were time consuming and requires a large quantity of mobile phase. The new method was achieved by application of Chromolith® high performance RP-18 (100 x 4.6 mm, 5 μm) as the stationary phase and optimization of mobile phase ratio and flow rate. Mobile phase consisted of acetonitrile (ACN) and 3.8 mM trifluroacetic acid (TFA) solution of 80:20 ratio at flow rate of 2.2 mL/ min was obtained as the optimal conditions. Total elution time of the obtained surfactin peaks was four times quicker than various methods previously reported in the literature. The method described here allowed for fine separation of surfactin in standard sample (98 % purity) and surfactin in fermentation broth. (author)

  16. Fast and simple method for semiquantitative determination of calcium propionate in bread samples.

    Science.gov (United States)

    Phechkrajang, Chutima Matayatsuk; Yooyong, Surin

    2017-04-01

    Calcium propionate has been widely used as a preservative in bakery and in bread. It is sometimes not carefully used, or a high concentration is added to preserve products. High consumption of calcium propionate can lead to several health problems. This study aims to develop a fast and simple semiquantitative method based on color complex formation for the determination of calcium propionate in a bread sample. A red-brown complex was obtained from the reaction of ferric ammonium sulfate and propionate anion. The product was rapidly formed and easily observed with the concentration of propionate anion >0.4 mg/mL. A high-performance liquid chromatography (HPLC) method was also developed and validated for comparison. Twenty-two bread samples from three markets near Bangkok were randomly selected and assayed for calcium propionate using the above two developed methods. The results showed that 19/22 samples contained calcium propionate >2000 mg/kg. The results of the complex formation method agreed with the HPLC method. Copyright © 2016. Published by Elsevier B.V.

  17. A simple method to separate red wine nonpolymeric and polymeric phenols by solid-phase extraction.

    Science.gov (United States)

    Pinelo, Manuel; Laurie, V Felipe; Waterhouse, Andrew L

    2006-04-19

    Simple polyphenols and tannins differ in the way that they contribute to the organoleptic profile of wine and their effects on human health. Very few straightforward techniques to separate red wine nonpolymeric phenols from the polymeric fraction are available in the literature. In general, they are complex, time-consuming, and generate large amounts of waste. In this procedure, the separation of these compounds was achieved using C18 cartridges, three solvents with different elution strengths, and pH adjustments of the experimental matrices. Two full factorial 2(3) experimental designs were performed to find the optimal critical variables and their values, allowing for the maximization of tannin recovery and separation efficiency (SE). Nonpolymeric phenols such as phenolic acids, monomers, and oligomers of flavonol and flavan-3-ols and anthocyanins were removed from the column by means of an aqueous solvent followed by ethyl acetate. The polymeric fraction was then eluted with a combination of methanol/acetone/water. The best results were attained with 1 mL of wine sample, a 10% methanol/water solution (first eluant), ethyl acetate (second eluant), and 66% acetone/water as the polymeric phenols-eluting solution (third eluant), obtaining a SE of ca. 90%. Trials with this method on fruit juices also showed high separation efficiency. Hence, this solid-phase extraction method has been shown to be a simple and efficient alternative for the separation of nonpolymeric phenolic fractions and the polymeric ones, and this method could have important applications to sample purification prior to biological testing due to the nonspecific binding of polymeric phenolics to nearly all enzymes and receptor sites.

  18. A simple method for the verification of clearance levels for non-radioactive solid waste

    International Nuclear Information System (INIS)

    Holland, B.

    1997-01-01

    ANSTO's radiopharmaceutical production laboratories generate 25 m 3 of solid waste per month. Most of this waste is not radioactive. Up until recently the non-radioactive waste was cleared from the controlled area and stored for 10 halflives prior to disposal as normal solid refuse. To eliminate the storage and ''double handling'' of the large quantities of non-radioactive waste a simple clearance method was devised to allow direct disposal. This paper describes how clearance levels were determined. Here the term ''clearance level'' is used as a general term for the release of material regardless of whether it was previously subject to regulatory control. This contrasts with the IAEA definition of a clearance level and highlights a potential problem with the implementation of exemption levels to keep material out of regulatory control and the use of clearance levels to allow removal of materials from regulatory control. Several common hand held contamination monitors were tested to determine their limits of detection and ability to meet these clearance levels. The clearance method includes waste segregation and size limitation features to ensure the waste is monitored in a consistent manner, compatible with the limits of detection. The clearance levels achieved were subsequently found to be compatible with some of the unconditional clearance levels in IAEA-TECDOC-855 and the measurement method also meets the required features of that document. The ANSTO non-radioactive waste clearance system has been in operation for more than 12 months and has proved simple and effective to operate. Approximately 12m 3 of the solid waste is now been treated directly as normal solid refuse. This paper describes the ANSTO clearance system, the contamination monitor tests and details practical problems associated with the direct monitoring of solid waste, including averaging of the activity in the package. The paper also briefly highlights the potential problem with the use of

  19. A simple and efficient method for assembling TALE protein based on plasmid library.

    Science.gov (United States)

    Zhang, Zhiqiang; Li, Duo; Xu, Huarong; Xin, Ying; Zhang, Tingting; Ma, Lixia; Wang, Xin; Chen, Zhilong; Zhang, Zhiying

    2013-01-01

    DNA binding domain of the transcription activator-like effectors (TALEs) from Xanthomonas sp. consists of tandem repeats that can be rearranged according to a simple cipher to target new DNA sequences with high DNA-binding specificity. This technology has been successfully applied in varieties of species for genome engineering. However, assembling long TALE tandem repeats remains a big challenge precluding wide use of this technology. Although several new methodologies for efficiently assembling TALE repeats have been recently reported, all of them require either sophisticated facilities or skilled technicians to carry them out. Here, we described a simple and efficient method for generating customized TALE nucleases (TALENs) and TALE transcription factors (TALE-TFs) based on TALE repeat tetramer library. A tetramer library consisting of 256 tetramers covers all possible combinations of 4 base pairs. A set of unique primers was designed for amplification of these tetramers. PCR products were assembled by one step of digestion/ligation reaction. 12 TALE constructs including 4 TALEN pairs targeted to mouse Gt(ROSA)26Sor gene and mouse Mstn gene sequences as well as 4 TALE-TF constructs targeted to mouse Oct4, c-Myc, Klf4 and Sox2 gene promoter sequences were generated by using our method. The construction routines took 3 days and parallel constructions were available. The rate of positive clones during colony PCR verification was 64% on average. Sequencing results suggested that all TALE constructs were performed with high successful rate. This is a rapid and cost-efficient method using the most common enzymes and facilities with a high success rate.

  20. A Simple Method Using a Topography Correction Coefficient for Estimating Daily Distribution of Solar Irradiance in Complex Terrain

    International Nuclear Information System (INIS)

    Yun, J.I.

    2009-01-01

    Accurate solar radiation data are critical to evaluate major physiological responses of plants. For most upland crops and orchard plants growing in complex terrain, however, it is not easy for farmers or agronomists to access solar irradiance data. Here we suggest a simple method using a sun-slope geometry based topographical coefficient to estimate daily solar irradiance on any sloping surfaces from global solar radiation measured at a nearby weather station. An hourly solar irradiance ratio (W i ) between sloping and horizontal surface is defined as multiplication of the relative solar intensity (k i ) and the slope irradiance ratio (r i ) at an hourly interval. The k i is the ratio of hourly solar radiation to the 24 hour cumulative radiation on a horizontal surface under clear sky conditions. The r i is the ratio of clear sky radiation on a given slope to that on a horizontal reference. Daily coefficient for slope correction is simply the sum of W i on each date. We calculated daily solar irradiance at 8 side slope locations circumventing a cone-shaped parasitic volcano (c.a., 570 m diameter for the bottom circle and 90 m bottom-to-top height) by multiplying these coefficients to the global solar radiation measured horizontally. Comparison with the measured slope irradiance from April 2007 to March 2008 resulted in the root mean square error (RMSE) of 1.61 MJ m −2 for the whole period but the RMSE for April to October (i.e., major cropping season in Korea) was much lower and satisfied the 5% error tolerance for radiation measurement. The RMSE was smallest in October regardless of slope aspect, and the aspect dependent variation of RMSE was greatest in November. Annual variation in RMSE was greatest on north and south facing slopes, followed by southwest, southeast, and northwest slopes in decreasing order. Once the coefficients are prepared, global solar radiation data from nearby stations can be easily converted to the solar irradiance map at landscape

  1. A simple method for the prevention of endometrial autolysis in hysterectomy specimens.

    Science.gov (United States)

    Houghton, J P; Roddy, S; Carroll, S; McCluggage, W G

    2004-03-01

    Uteri are among the most common surgical pathology specimens. Assessment of the endometrium is often difficult because of pronounced tissue autolysis. This study describes a simple method to prevent endometrial autolysis and aid in interpretation of the endometrium. Sixty uteri were injected with formalin using a needle and syringe directed alongside a probe, which was inserted through the external cervical os into the endometrial cavity. Injection was performed on the same day as removal of the uterus. As controls, 60 uteri that were not injected with formalin were examined. The degree of endometrial autolysis was assessed on a four point scale (0-3), with a score of 0 representing no or minimal autolysis and a score of 3 representing extensive autolysis, such that histological interpretation of the endometrium was impossible. In the injected group, the number of cases with scores of 0, 1, 2, and 3 was 42, 13, four, and one, respectively. The corresponding values for the control group were 17, 23, eight, and 12, respectively. This was highly significant (p autolysis in uteri injected with formalin. The use of this simple procedure should be encouraged in hysterectomy specimens.

  2. Outcomes in Patients Treated with a Novel, Simple Method for Hemostasis of Dermal Avulsion Injuries.

    Science.gov (United States)

    Dowling, Sean Taylor; Lin, Brian Wai

    2017-10-01

    A recently described technique proposes a simple method to achieve permanent hemostasis of distal fingertip dermal avulsion injuries. It is simple to learn and easy to perform with readily available materials found in most emergency departments. However, long-term outcomes for patients treated with this technique have not yet been evaluated. A primary objective of the current article is to provide safety data for the technique using an off-label product indication. Emergency department of Kaiser Permanente Medical Center, San Francisco, California. Six patients were treated in the emergency department for fingertip dermal avulsion injuries using a tourniquet and tissue adhesive glue (Dermabond by Ethicon, Somerville, New Jersey). Patients were subsequently contacted to assess healing and satisfaction with cosmetic outcome through interview and photographs of their wounds at 9 months following the date of injury. All 6 patients were satisfied with the cosmetic outcome of treatment, and none received a diagnosis of serious complications. This series demonstrates cosmetic outcomes for injuries treated with the technique, highlights potential problems that may be perceived by patients during their clinical course, and creates the groundwork for a larger clinical study examining the use of the technique.

  3. An operationally simple method for separating the rare-earth elements neodymium and dysprosium

    Energy Technology Data Exchange (ETDEWEB)

    Bogart, Justin A.; Lippincott, Connor A.; Carroll, Patrick J.; Schelter, Eric J. [Department of Chemistry, University of Pennsylvania, Philadelphia, PA (United States)

    2015-07-06

    Rare-earth metals are critical components of electronic materials and permanent magnets. Recycling of consumer materials is a promising new source of rare earths. To incentivize recycling there is a clear need for simple methods for targeted separations of mixtures of rare-earth metal salts. Metal complexes of a tripodal nitroxide ligand [{(2-"tBuNO)C_6H_4CH_2}{sub 3}N]{sup 3-} (TriNOx{sup 3-}), feature a size-sensitive aperture formed of its three η{sup 2}-(N,O) ligand arms. Exposure of metal cations in the aperture induces a self-associative equilibrium comprising [M(TriNOx)thf]/[M(TriNOx)]{sub 2} (M=rare-earth metal). Differences in the equilibrium constants (K{sub eq}) for early and late metals enables simple Nd/Dy separations through leaching with a separation ratio S{sub Nd/Dy}=359. (copyright 2015 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  4. Rapid and simple colorimetric method for the quantification of AI-2 produced from Salmonella Typhimurium.

    Science.gov (United States)

    Wattanavanitchakorn, Siriluck; Prakitchaiwattana, Cheunjit; Thamyongkit, Patchanita

    2014-04-01

    The aim of this study was to evaluate the feasibility of Fe(III) ion reduction for the simple and rapid quantification of autoinducer-2 (AI-2) produced from bacteria using Salmonella Typhimurium as a model. Since the molecular structure of AI-2 is somewhat similar to ascorbic acid it was expected that AI-2 would also act as a reducing agent and reduce Fe(III) ions in the presence of 1,10-phenanthroline to form the colored [(o-phen)3 Fe(II)]SO4 ferroin complex that could be quantified colorimetrically. In support of this, colony rinses and cell free supernatants from cultures of all tested AI-2 producing strains, but not the AI-2 negative Sinorhizobium meliloti, formed a colored complex with a λmax of 510nm. The OD510 values of these culture supernatants or colony rinses were in broad agreement with the % activity observed in the same samples using the standard Vibrio harveyi bioluminescence assay for AI-2 detection, and with previously reported results. This methodology could potentially be developed as an alternative method for the simple and rapid quantification of AI-2 levels produced in bacterial cultures. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Linearized self-consistent quasiparticle GW method: Application to semiconductors and simple metals

    International Nuclear Information System (INIS)

    Kutepov, A. L.

    2017-01-01

    We present a code implementing the linearized self-consistent quasiparticle GW method (QSGW) in the LAPW basis. Our approach is based on the linearization of the self-energy around zero frequency which differs it from the existing implementations of the QSGW method. The linearization allows us to use Matsubara frequencies instead of working on the real axis. This results in efficiency gains by switching to the imaginary time representation in the same way as in the space time method. The all electron LAPW basis set eliminates the need for pseudopotentials. We discuss the advantages of our approach, such as its N 3 scaling with the system size N, as well as its shortcomings. We apply our approach to study the electronic properties of selected semiconductors, insulators, and simple metals and show that our code produces the results very close to the previously published QSGW data. Our implementation is a good platform for further many body diagrammatic resummations such as the vertex-corrected GW approach and the GW+DMFT method.

  6. A simple method for assigning genomic grade to individual breast tumours

    International Nuclear Information System (INIS)

    Wennmalm, Kristian; Bergh, Jonas

    2011-01-01

    The prognostic value of grading in breast cancer can be increased with microarray technology, but proposed strategies are disadvantaged by the use of specific training data or parallel microscopic grading. Here, we investigate the performance of a method that uses no information outside the breast profile of interest. In 251 profiled tumours we optimised a method that achieves grading by comparing rank means for genes predictive of high and low grade biology; a simpler method that allows for truly independent estimation of accuracy. Validation was carried out in 594 patients derived from several independent data sets. We found that accuracy was good: for low grade (G1) tumors 83- 94%, for high grade (G3) tumors 74- 100%. In keeping with aim of improved grading, two groups of intermediate grade (G2) cancers with significantly different outcome could be discriminated. This validates the concept of microarray-based grading in breast cancer, and provides a more practical method to achieve it. A simple R script for grading is available in an additional file. Clinical implementation could achieve better estimation of recurrence risk for 40 to 50% of breast cancer patients

  7. A simple nodal force distribution method in refined finite element meshes

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jai Hak [Chungbuk National University, Chungju (Korea, Republic of); Shin, Kyu In [Gentec Co., Daejeon (Korea, Republic of); Lee, Dong Won [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Cho, Seungyon [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2017-05-15

    In finite element analyses, mesh refinement is frequently performed to obtain accurate stress or strain values or to accurately define the geometry. After mesh refinement, equivalent nodal forces should be calculated at the nodes in the refined mesh. If field variables and material properties are available at the integration points in each element, then the accurate equivalent nodal forces can be calculated using an adequate numerical integration. However, in certain circumstances, equivalent nodal forces cannot be calculated because field variable data are not available. In this study, a very simple nodal force distribution method was proposed. Nodal forces of the original finite element mesh are distributed to the nodes of refined meshes to satisfy the equilibrium conditions. The effect of element size should also be considered in determining the magnitude of the distributing nodal forces. A program was developed based on the proposed method, and several example problems were solved to verify the accuracy and effectiveness of the proposed method. From the results, accurate stress field can be recognized to be obtained from refined meshes using the proposed nodal force distribution method. In example problems, the difference between the obtained maximum stress and target stress value was less than 6 % in models with 8-node hexahedral elements and less than 1 % in models with 20-node hexahedral elements or 10-node tetrahedral elements.

  8. The minisequencing method: a simple strategy for genetic screening of MEN 2 families

    Directory of Open Access Journals (Sweden)

    Domingues Rita

    2002-05-01

    Full Text Available Abstract Background Multiple endocrine neoplasia type 2 is an autosomal dominant disorder. MEN 2A is characterized by medullary thyroid carcinoma, pheochromocytoma and hyperparathyroidism; MEN 2B by medullary thyroid carcinoma, pheochromocytoma and characteristic stigmata. Activating germline mutations of the RET proto oncogene are responsible for this hereditary syndrome. Codon 634 mutations are the most common mutations occurring in MEN 2A families whereas a specific mutation at codon 918 is observed in the great majority of MEN 2B families. Analysis of these codons will provide a final diagnosis in the great majority of affected families making unnecessary further studies. To specifically study the codons 634 and 918 we used a minisequencing method as an alternative method to complete sequencing. Results Using this mutation detection method we were able to reproduce in all cases, representative of 7 families, the information previously obtained by direct sequencing of PCR products. Depending on the number of primers used in the minisequencing reaction, we were able to interrogate either only one nucleotide of the target codon or the three nucleotides simultaneously. Conclusions This technique appears as a simple, rapid and efficient method for genetic screening of MEN 2 families. It can be utilized to seek for unknown mutations at specific codons or to screen for previously identified mutations and is therefore of interest to study index cases or individuals at risk. Results suggest that complete sequencing is unnecessary.

  9. Simple and Reliable Method to Estimate the Fingertip Static Coefficient of Friction in Precision Grip.

    Science.gov (United States)

    Barrea, Allan; Bulens, David Cordova; Lefevre, Philippe; Thonnard, Jean-Louis

    2016-01-01

    The static coefficient of friction (µ static ) plays an important role in dexterous object manipulation. Minimal normal force (i.e., grip force) needed to avoid dropping an object is determined by the tangential force at the fingertip-object contact and the frictional properties of the skin-object contact. Although frequently assumed to be constant for all levels of normal force (NF, the force normal to the contact), µ static actually varies nonlinearly with NF and increases at low NF levels. No method is currently available to measure the relationship between µ static and NF easily. Therefore, we propose a new method allowing the simple and reliable measurement of the fingertip µ static at different NF levels, as well as an algorithm for determining µ static from measured forces and torques. Our method is based on active, back-and-forth movements of a subject's finger on the surface of a fixed six-axis force and torque sensor. µ static is computed as the ratio of the tangential to the normal force at slip onset. A negative power law captures the relationship between µ static and NF. Our method allows the continuous estimation of µ static as a function of NF during dexterous manipulation, based on the relationship between µ static and NF measured before manipulation.

  10. A Simple and Efficient Method for Preparing Cell Slides and Staining without Using Cytocentrifuge and Cytoclips

    Directory of Open Access Journals (Sweden)

    Xiaotang Hu

    2015-01-01

    Full Text Available Cell staining is a necessary and useful technique for visualizing cell morphology and structure under a microscope. This technique has been used in many areas such as cytology, hematology, oncology, histology, virology, serology, microbiology, cell biology, and immunochemistry. One of the key pieces of equipment for preparing a slide for cell staining is cytology centrifuge (cytocentrifuge such as cytospin. However, many small labs do not have this expensive equipment and its accessory, cytoclips (also expensive relatively, which makes them difficult to study cell cytology. Here we present an alternative method for preparing a slide and cell staining in the absence of a cytocentrifuge (and cytoclips. This method is based on the principle that a regular cell centrifuge can be used to concentrate cells harvested from cell culture and then deposit the concentrated cell suspension to a slide evenly by using a cell spreader, followed by cell staining. The method presented is simple, rapid, economic, and efficient. This method may also avoid a possible change in cell morphology induced by cytocentrifuge.

  11. A Simple Method for Assessing Upper-Limb Force-Velocity Profile in Bench Press.

    Science.gov (United States)

    Rahmani, Abderrahmane; Samozino, Pierre; Morin, Jean-Benoit; Morel, Baptiste

    2018-02-01

    To analyze the reliability and validity of a field computation method based on easy-to-measure data to assess the mean force ([Formula: see text]) and velocity ([Formula: see text]) produced during a ballistic bench-press movement and to verify that the force-velocity profile (F-v) obtained with multiple loaded trials is accurately described. Twelve participants performed ballistic bench presses against various lifted mass from 30% to 70% of their body mass. For each trial, [Formula: see text] and [Formula: see text] were determined from an accelerometer (sampling rate 500 Hz; reference method) and a simple computation method based on upper-limb mass, barbell flight height, and push-off distance. These [Formula: see text] and [Formula: see text] data were used to establish the F-v relationship for each individual and method. A strong to almost perfect reliability was observed between the 2 trials (ICC > .90 for [Formula: see text] and .80 for [Formula: see text], CV%  .80, P push-off distance).

  12. A simple method to identify areas of environmental risk due to manure application.

    Science.gov (United States)

    Flores, Héctor; Arumí, José Luis; Rivera, Diego; Lagos, L Octavio

    2012-06-01

    The management of swine manure is becoming an important environmental issue in Chile. One option for the final disposal of manure is to use it as a biofertilizer, but this practice could impact the surrounding environment. To assess the potential environmental impacts of the use of swine manure as a biofertilizer, we propose a method to identify zones of environmental risk through indices. The method considers two processes: nutrient runoff and solute leaching, and uses available information about soils, crops and management practices (irrigation, fertilization, and rotation). We applied the method to qualitatively assess the environmental risk associated with the use of swine manure as a biofertilizer in an 8,000-pig farm located in Central Chile. Results showed that the farm has a moderate environmental risk, but some specific locations have high environmental risks, especially those associated with impacts on areas surrounding water resources. This information could assist the definition of better farm-level management practices, as well as the preservation of riparian vegetation acting as buffer strips. The main advantage of our approach is that it combines qualitative and quantitative information, including particular situations or field features based on expert knowledge. The method is flexible, simple, and can be easily extended or adapted to other processes.

  13. Simulation Opportunity Index, A Simple and Effective Method to Boost the Hydrocarbon Recovery

    KAUST Repository

    Saputra, Wardana

    2016-09-08

    During periods of low oil prices, profitability of field developments drops drastically. To help with this difficulty, a cost-effective method has been proposed to boost the hydrocarbon recovery by optimizing well locations through the Simulated Opportunity Index (SOI). SOI is an intelligent method to identify zones with high potential for production which is empirically calculated from basic rock and fluid properties, and from reservoir pressure as its energy capacity. In order to obtain the best results, the original SOI formula (Molina et al., 2009) was extended to both oil and gas fields. Based on this modified SOI formula, a software program has been developed to locate the best well locations considering multilayer, existing wells, and fault existences. This paper describes how the SOI software helps as a simple, fast, and accurate way to obtain the higher hydrocarbon production than that of trial-error method and previous studies in two different fields located in offshore Indonesia. On one hand, the proposed method could save money by minimizing the required number of wells. On the other hand, it could maximize profit by maximizing recovery.

  14. Simple method of testing polymer leaching from thermoplastic sheets used for clear aligner

    Directory of Open Access Journals (Sweden)

    Shuvana Altaf Ansari

    2014-01-01

    Full Text Available Objective: With the increasing popularity of clear aligners, newer materials are introduced in the form of thermoplastic sheets. Long-term studies testing the biocompatibility of these sheets are not available. The purpose of this study is to provide a simple, yet effective method to evaluate their leaching potential. Materials and Methods: Using the oxidation reduction reaction taking place in the presence of two different concentrations of potassium permanganate, five different samples were tested. The sequence of colour change from purple to red to brown to yellow to clear was used to determine the amount of leaching. This is the result of a stoichiometric relation between the oxidizing agent and the reducing sample. Color changes were observed through naked eyes over a period of 24 h. Photographs were taken at 15 min, 8 h and 24 h using D-SLR1000 Canon camera. Photos were evaluated separately. Result: Diluted solution showed faster change in color, due to the lesser amount of reagent. 3A Medes (Korea was the first to leach, followed by CA (Scheu, Germany EVA (Endent Private Limited, Delhi, India, Ultradent (United States and Avac R (Jaypee, Kerela, India. Conclusion: "Do it yourself" test is a repeatable and reproducible method that can be modified and used in clinical practice as a chair side method.

  15. A simple method for assigning genomic grade to individual breast tumours

    Directory of Open Access Journals (Sweden)

    Bergh Jonas

    2011-07-01

    Full Text Available Abstract Background The prognostic value of grading in breast cancer can be increased with microarray technology, but proposed strategies are disadvantaged by the use of specific training data or parallel microscopic grading. Here, we investigate the performance of a method that uses no information outside the breast profile of interest. Results In 251 profiled tumours we optimised a method that achieves grading by comparing rank means for genes predictive of high and low grade biology; a simpler method that allows for truly independent estimation of accuracy. Validation was carried out in 594 patients derived from several independent data sets. We found that accuracy was good: for low grade (G1 tumors 83- 94%, for high grade (G3 tumors 74- 100%. In keeping with aim of improved grading, two groups of intermediate grade (G2 cancers with significantly different outcome could be discriminated. Conclusion This validates the concept of microarray-based grading in breast cancer, and provides a more practical method to achieve it. A simple R script for grading is available in an additional file. Clinical implementation could achieve better estimation of recurrence risk for 40 to 50% of breast cancer patients.

  16. Simple method for highlighting the temperature distribution into a liquid sample heated by microwave power field

    International Nuclear Information System (INIS)

    Surducan, V.; Surducan, E.; Dadarlat, D.

    2013-01-01

    Microwave induced heating is widely used in medical treatments, scientific and industrial applications. The temperature field inside a microwave heated sample is often inhomogenous, therefore multiple temperature sensors are required for an accurate result. Nowadays, non-contact (Infra Red thermography or microwave radiometry) or direct contact temperature measurement methods (expensive and sophisticated fiber optic temperature sensors transparent to microwave radiation) are mainly used. IR thermography gives only the surface temperature and can not be used for measuring temperature distributions in cross sections of a sample. In this paper we present a very simple experimental method for temperature distribution highlighting inside a cross section of a liquid sample, heated by a microwave radiation through a coaxial applicator. The method proposed is able to offer qualitative information about the heating distribution, using a temperature sensitive liquid crystal sheet. Inhomogeneities as smaller as 1°-2°C produced by the symmetry irregularities of the microwave applicator can be easily detected by visual inspection or by computer assisted color to temperature conversion. Therefore, the microwave applicator is tuned and verified with described method until the temperature inhomogeneities are solved

  17. Simple mathematical method to quantify p53 mutations in occupational lung cancer

    International Nuclear Information System (INIS)

    Helal, N.L.

    2005-01-01

    Radon-222, a decay product of uranium-238 and a source of high linear energy transfer (LET) alpha -particles, has been implicated in the increase risk of lung cancer in uranium miners as well as non-miners. The p53 gene mutational spectrum reveals evidence for a direct causal effect of radon inhalation in lung cancer. This mutation has been proposed as a marker of radon exposure. The development of such markers may ultimately be of benefit in the reduction of occupational morbidity and mortality from occupational cancer. One of the tasks in risk assessment of genotoxic occupational radiation exposure is to devise a simple numerical method. This method may be used to quantify the relationship between radiation dose and the effect on the genetic sequences. The tumor suppressor gene (TSG) p53 is an ideal bio marker addressing questions of exposure and risk. These proteins may be suitable for the design of more effective or less invasive cancer therapies. The clinical outcome of lung cancer patients may correlate with the normal regulation of these patients and, therefore, their identification may be used as a guideline for future therapy modalities. To investigate the association between radon exposure and p53 mutations in lung tumors, we have implied a mathematical method. This method has been developed from a 2-D graphical representational technique that enables easy visualization of base distributions. This is of special relevance to libraries of single nucleotide polymorphic (SNP) genes

  18. Linearized self-consistent quasiparticle GW method: Application to semiconductors and simple metals

    Science.gov (United States)

    Kutepov, A. L.; Oudovenko, V. S.; Kotliar, G.

    2017-10-01

    We present a code implementing the linearized quasiparticle self-consistent GW method (LQSGW) in the LAPW basis. Our approach is based on the linearization of the self-energy around zero frequency which differs it from the existing implementations of the QSGW method. The linearization allows us to use Matsubara frequencies instead of working on the real axis. This results in efficiency gains by switching to the imaginary time representation in the same way as in the space time method. The all electron LAPW basis set eliminates the need for pseudopotentials. We discuss the advantages of our approach, such as its N3 scaling with the system size N, as well as its shortcomings. We apply our approach to study the electronic properties of selected semiconductors, insulators, and simple metals and show that our code produces the results very close to the previously published QSGW data. Our implementation is a good platform for further many body diagrammatic resummations such as the vertex-corrected GW approach and the GW+DMFT method. Program Files doi:http://dx.doi.org/10.17632/cpchkfty4w.1 Licensing provisions: GNU General Public License Programming language: Fortran 90 External routines/libraries: BLAS, LAPACK, MPI (optional) Nature of problem: Direct implementation of the GW method scales as N4 with the system size, which quickly becomes prohibitively time consuming even in the modern computers. Solution method: We implemented the GW approach using a method that switches between real space and momentum space representations. Some operations are faster in real space, whereas others are more computationally efficient in the reciprocal space. This makes our approach scale as N3. Restrictions: The limiting factor is usually the memory available in a computer. Using 10 GB/core of memory allows us to study the systems up to 15 atoms per unit cell.

  19. Performance of the Tariff Method: validation of a simple additive algorithm for analysis of verbal autopsies

    Directory of Open Access Journals (Sweden)

    Murray Christopher JL

    2011-08-01

    Full Text Available Abstract Background Verbal autopsies provide valuable information for studying mortality patterns in populations that lack reliable vital registration data. Methods for transforming verbal autopsy results into meaningful information for health workers and policymakers, however, are often costly or complicated to use. We present a simple additive algorithm, the Tariff Method (termed Tariff, which can be used for assigning individual cause of death and for determining cause-specific mortality fractions (CSMFs from verbal autopsy data. Methods Tariff calculates a score, or "tariff," for each cause, for each sign/symptom, across a pool of validated verbal autopsy data. The tariffs are summed for a given response pattern in a verbal autopsy, and this sum (score provides the basis for predicting the cause of death in a dataset. We implemented this algorithm and evaluated the method's predictive ability, both in terms of chance-corrected concordance at the individual cause assignment level and in terms of CSMF accuracy at the population level. The analysis was conducted separately for adult, child, and neonatal verbal autopsies across 500 pairs of train-test validation verbal autopsy data. Results Tariff is capable of outperforming physician-certified verbal autopsy in most cases. In terms of chance-corrected concordance, the method achieves 44.5% in adults, 39% in children, and 23.9% in neonates. CSMF accuracy was 0.745 in adults, 0.709 in children, and 0.679 in neonates. Conclusions Verbal autopsies can be an efficient means of obtaining cause of death data, and Tariff provides an intuitive, reliable method for generating individual cause assignment and CSMFs. The method is transparent and flexible and can be readily implemented by users without training in statistics or computer science.

  20. A simple Ultraviolet spectrophotometric method for the determination of etoricoxib in dosage formulations

    Directory of Open Access Journals (Sweden)

    Shipra Singh

    2012-01-01

    Full Text Available The present study was undertaken to develop a validated, rapid, simple, and low-cost ultraviolet (UV spectrophotometric method for estimating Etoricoxib (ETX in pharmaceutical formulations. The analysis was performed on λ max 233 nm using 0.1 M HCl as blank/diluent. The proposed method was validated on International Conference on Harmonization (ICH guidelines including parameters as linearity, accuracy, precision, reproducibility, and specificity. The proposed method was also used to access the content of the ETX in two commercial brands of Indian market. Beer′s law was obeyed in concentration range of 0.1-0.5 μg/ml, and the regression equation was Y = 0.418x + 0.018. The mean accuracy values for 0.1 μg/ml and 0.2 μg/ml concentration of ETX were found to be 99.76 ± 0.52% and 99.12 ± 0.84, respectively, and relative standard deviation (RSD of interday and intraday was less than 2%. The developed method was suitable and specific to the analysis of ETX even in the presence of common excipients. The method was applied on two different marketed brands and ETX contents were 98.5 ± 0.56 and 99.33 ± 0.44, respectively, of labeled claim. The proposed method was validated as per ICH guidelines and statistically good results were obtained. This method can be employed for routine analysis of ETX in bulk and commercial formulations.

  1. A simple Ultraviolet spectrophotometric method for the determination of etoricoxib in dosage formulations.

    Directory of Open Access Journals (Sweden)

    S Singh

    2012-01-01

    Full Text Available The present study was undertaken to develop a validated, rapid, simple, and low-cost ultraviolet (UV spectrophotometric method for estimating Etoricoxib (ETX in pharmaceutical formulations. The analysis was performed on Î max 233 nm using 0.1 M HCl as blank/diluent. The proposed method was validated on International Conference on Harmonization (ICH guidelines including parameters as linearity, accuracy, precision, reproducibility, and specificity. The proposed method was also used to access the content of the ETX in two commercial brands of Indian market. Beer′s law was obeyed in concentration range of 0.1-0.5 μg/ml, and the regression equation was Y = 0.418x + 0.018. The mean accuracy values for 0.1 μg/ml and 0.2 μg/ml concentration of ETX were found to be 99.76 ± 0.52% and 99.12 ± 0.84, respectively, and relative standard deviation (RSD of interday and intraday was less than 2%. The developed method was suitable and specific to the analysis of ETX even in the presence of common excipients. The method was applied on two different marketed brands and ETX contents were 98.5 ± 0.56 and 99.33 ± 0.44, respectively, of labeled claim. The proposed method was validated as per ICH guidelines and statistically good results were obtained. This method can be employed for routine analysis of ETX in bulk and commercial formulations.

  2. A Simple yet Accurate Method for the Estimation of the Biovolume of Planktonic Microorganisms.

    Science.gov (United States)

    Saccà, Alessandro

    2016-01-01

    Determining the biomass of microbial plankton is central to the study of fluxes of energy and materials in aquatic ecosystems. This is typically accomplished by applying proper volume-to-carbon conversion factors to group-specific abundances and biovolumes. A critical step in this approach is the accurate estimation of biovolume from two-dimensional (2D) data such as those available through conventional microscopy techniques or flow-through imaging systems. This paper describes a simple yet accurate method for the assessment of the biovolume of planktonic microorganisms, which works with any image analysis system allowing for the measurement of linear distances and the estimation of the cross sectional area of an object from a 2D digital image. The proposed method is based on Archimedes' principle about the relationship between the volume of a sphere and that of a cylinder in which the sphere is inscribed, plus a coefficient of 'unellipticity' introduced here. Validation and careful evaluation of the method are provided using a variety of approaches. The new method proved to be highly precise with all convex shapes characterised by approximate rotational symmetry, and combining it with an existing method specific for highly concave or branched shapes allows covering the great majority of cases with good reliability. Thanks to its accuracy, consistency, and low resources demand, the new method can conveniently be used in substitution of any extant method designed for convex shapes, and can readily be coupled with automated cell imaging technologies, including state-of-the-art flow-through imaging devices.

  3. A Simple yet Accurate Method for the Estimation of the Biovolume of Planktonic Microorganisms.

    Directory of Open Access Journals (Sweden)

    Alessandro Saccà

    Full Text Available Determining the biomass of microbial plankton is central to the study of fluxes of energy and materials in aquatic ecosystems. This is typically accomplished by applying proper volume-to-carbon conversion factors to group-specific abundances and biovolumes. A critical step in this approach is the accurate estimation of biovolume from two-dimensional (2D data such as those available through conventional microscopy techniques or flow-through imaging systems. This paper describes a simple yet accurate method for the assessment of the biovolume of planktonic microorganisms, which works with any image analysis system allowing for the measurement of linear distances and the estimation of the cross sectional area of an object from a 2D digital image. The proposed method is based on Archimedes' principle about the relationship between the volume of a sphere and that of a cylinder in which the sphere is inscribed, plus a coefficient of 'unellipticity' introduced here. Validation and careful evaluation of the method are provided using a variety of approaches. The new method proved to be highly precise with all convex shapes characterised by approximate rotational symmetry, and combining it with an existing method specific for highly concave or branched shapes allows covering the great majority of cases with good reliability. Thanks to its accuracy, consistency, and low resources demand, the new method can conveniently be used in substitution of any extant method designed for convex shapes, and can readily be coupled with automated cell imaging technologies, including state-of-the-art flow-through imaging devices.

  4. Analysis of rhythmic variance - ANORVA. A new simple method for detecting rhythms in biological time series

    Directory of Open Access Journals (Sweden)

    Peter Celec

    2004-01-01

    Full Text Available Cyclic variations of variables are ubiquitous in biomedical science. A number of methods for detecting rhythms have been developed, but they are often difficult to interpret. A simple procedure for detecting cyclic variations in biological time series and quantification of their probability is presented here. Analysis of rhythmic variance (ANORVA is based on the premise that the variance in groups of data from rhythmic variables is low when a time distance of one period exists between the data entries. A detailed stepwise calculation is presented including data entry and preparation, variance calculating, and difference testing. An example for the application of the procedure is provided, and a real dataset of the number of papers published per day in January 2003 using selected keywords is compared to randomized datasets. Randomized datasets show no cyclic variations. The number of papers published daily, however, shows a clear and significant (p<0.03 circaseptan (period of 7 days rhythm, probably of social origin

  5. Synthesis of cerium oxide (CeO{sub 2}) nanoparticles using simple CO-precipitation method

    Energy Technology Data Exchange (ETDEWEB)

    Farahmandjou, M.; Zarinkamar, M.; Firoozabadi, T. P., E-mail: farahamndjou@iauvaramin.ac.ir [Islamis Azad University, Varamin-Phisva Branch, Department of Physics, Varamin (Iran, Islamic Republic of)

    2016-11-01

    Synthesis of cerium oxide (CeO{sub 2}) nanoparticles was studied by new and simple co-precipitation method. The cerium oxide nanoparticles were synthesized using cerium nitrate and potassium carbonate precursors. Their physicochemical properties were characterized by high resolution transmission electron microscopy (HRTEM), scanning electron microscopy (Sem), X-ray diffraction (XRD), energy dispersive spectroscopy (EDS), Fourier transform infrared spectroscopy (Ftir) and UV-Vis spectrophotometer. XRD pattern showed the cubic structure of the cerium oxide nanoparticles. The average particle size of CeO{sub 2} was around 20 nm as estimated by XRD technique and direct HRTEM observations. The surface morphological studies from Sem and Tem depicted spherical particles with formation of clusters. The sharp peaks in Ftir spectrum determined the existence of CeO{sub 2} stretching mode and the absorbance peak of UV-Vis spectrum showed the bandgap energy of 3.26 eV. (Author)

  6. A simple method of fabricating mask-free microfluidic devices for biological analysis.

    KAUST Repository

    Yi, Xin

    2010-09-07

    We report a simple, low-cost, rapid, and mask-free method to fabricate two-dimensional (2D) and three-dimensional (3D) microfluidic chip for biological analysis researches. In this fabrication process, a laser system is used to cut through paper to form intricate patterns and differently configured channels for specific purposes. Bonded with cyanoacrylate-based resin, the prepared paper sheet is sandwiched between glass slides (hydrophilic) or polymer-based plates (hydrophobic) to obtain a multilayer structure. In order to examine the chip\\'s biocompatibility and applicability, protein concentration was measured while DNA capillary electrophoresis was carried out, and both of them show positive results. With the utilization of direct laser cutting and one-step gas-sacrificing techniques, the whole fabrication processes for complicated 2D and 3D microfluidic devices are shorten into several minutes which make it a good alternative of poly(dimethylsiloxane) microfluidic chips used in biological analysis researches.

  7. Unconfined twist : a simple method to prepare ultrafine grained metallic materials.

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Y. (Yonghao); Liao, Xiaozhou; Zhu, Y. T. (Yuntian Theodore)

    2004-01-01

    A new simple method - unconfined twist was employed to prepare ultrafine grained (UFG) Fe,wire. A coarse grained (CG) Fe wire with a diameter of 0.85 mm was fixed at one end, and twisted at the other end. After maximum twist before fracture, in the cross-sectional plane, concentrically deformed layers with a width of several micrometers formed surrounding the center axis of the wire. The near-surface deformed layers consist of lamella grains with a width in submicrometer range. In the longitudinal plane, deformed bands (with a width of several micrometers) formed uniformly, which were composed of lamella crystallites (with a width in submicrometer range). The tensile yield strength and ultimate strength of the twisted Fe wire are increased by about 150% and 100% compared with the values of its CG counterpart.

  8. Improving the security of chaotic encryption by using a simple modulating method

    International Nuclear Information System (INIS)

    Bu Shouliang; Wang Binghong

    2004-01-01

    In recent years, synchronization of chaotic systems has aroused much interest due to its potential application to secure communications. However, it is found by Perez and Cerdeira that an intruder, without the knowledge of the parameters of the system or even of the nonlinear system itself, may extract the messages from the carrier signal by producing a return map where the dynamics is attracted to an almost 1D set. To eliminate the weakness, in this letter, a simple but efficient method for synchronizing chaotic systems by modulating the transmitted signal with an appropriately choosing scalar signal is proposed. It turns out that this modulating strategy not only preserves all appropriate information required for synchronizing chaotic systems but also destroys the possibility of the phase space reconstruction of the sender dynamics such as a return map

  9. A simple and effective method to achieve the successful start-up of a current reference

    International Nuclear Information System (INIS)

    Han Lei; Zhang Xiaoxing; Dai Yujie; Lü Yingjie; Wang Yujun

    2012-01-01

    Start-up design is a critical issue in current reference as it is very closely related to production yield. However, its function is difficult to predict using normal transaction simulations before the device is put into diffusion. In this paper, we discuss a simple and effective simulation approach which ensures a successful start-up process in a self-biased temperature independent current reference. The circuit is implemented in a class-D power amplifier with a 0.35 μm BiCMOS process and the experimental result validates that, by using this method, the start-up success rate can be greatly improved to 100%. (semiconductor integrated circuits)

  10. Simple analytical method for acrylamide in the workplace air adsorbed by charcoal tube

    Energy Technology Data Exchange (ETDEWEB)

    Yang, J S; Lee, M Y; Park, I J; Kang, S K [Korea Industrial Safety corporation, Inchon (Korea, Republic of)

    1998-04-01

    For the ambient monitoring of acrylamide, the adequate condition of sampling and analysis was checked. The adequate adsorbents and desorption solvents were tested. The combination of char-coal tube as a adsorbent and acetone as a desorption solvent showed 87% desorption efficiency. Flame ionization detector was used to detect acrylamide. The detection limit was 0.814 mg acrylamide in 1 L acetone. It is the equivalent concentration of 0.0203 mg acrylamide in 1 3{sup 3} air if the volume of air collected was 40 L. The permissible exposure level (PEL) of acrylamide in the workplace air recommended by Occupational Safety and Health Administration (OSHA, USA) is 0.3 mg acrylamide in 1 m{sup 3} air. So, it is very simple and economic analytical method for acrylamide to be set in the industrial hygiene laboratories.

  11. A rapid and simple method for DNA extraction from yeasts and fungi isolated from Agave fourcroydes.

    Science.gov (United States)

    Tapia-Tussell, Raul; Lappe, Patricia; Ulloa, Miguel; Quijano-Ramayo, Andrés; Cáceres-Farfán, Mirbella; Larqué-Saavedra, Alfonso; Perez-Brito, Daisy

    2006-05-01

    A simple and easy protocol for extracting high-quality DNA from different yeast and filamentous fungal species is described. This method involves two important steps: first, the disruption of cell walls by mechanical means and freezing; and second, the extraction, isolation, and precipitation of genomic DNA. The absorbance ratios (A(260)/A(280)) obtained ranged from 1.6 to 2.0. The main objective of this procedure is to extract pure DNA from yeast and filamentous fungi, including those with high contents of proteins, polysaccharides, and other complex compounds in their cell walls. The yield and quality of the DNAs obtained were suitable for micro/minisatellite primer-polymerase chain reaction (MSP-PCR) fingerprinting as well as for the sequence of the D1/D2 domain of the 26S rDNA.

  12. A simple method of using a Foley catheter to drain pleural effusion.

    Science.gov (United States)

    Ben-Nun, Alon; Best, Lael Anson

    2008-01-01

    Pleural effusion is a common problem, and various techniques of pleural fluid drainage have been described. We report our experience of using a Foley-type catheter to drain pleural effusion. After the injection of local anesthesia, the catheter is inserted, usually through the 7th intercostal space, with the patient sitting upright. The size of the catheter is selected according to the predicted fluid characteristics, and ranges from 18 to 24 F. Once the catheter is positioned in the pleural space, the balloon is inflated with diluted soluble contrast material and connected to a urine collection bag. During the last 10 years, we have used 3500 catheters for this purpose. The catheter site can be used as a port for various procedures, including needle biopsy of the parietal pleura, talc-slurry pleurodesis, and intra-pleural fibrinolysis. This method of pleural drainage is simple, reliable, and inexpensive.

  13. A simple method to calculate first-passage time densities with arbitrary initial conditions

    Science.gov (United States)

    Nyberg, Markus; Ambjörnsson, Tobias; Lizana, Ludvig

    2016-06-01

    Numerous applications all the way from biology and physics to economics depend on the density of first crossings over a boundary. Motivated by the lack of general purpose analytical tools for computing first-passage time densities (FPTDs) for complex problems, we propose a new simple method based on the independent interval approximation (IIA). We generalise previous formulations of the IIA to include arbitrary initial conditions as well as to deal with discrete time and non-smooth continuous time processes. We derive a closed form expression for the FPTD in z and Laplace-transform space to a boundary in one dimension. Two classes of problems are analysed in detail: discrete time symmetric random walks (Markovian) and continuous time Gaussian stationary processes (Markovian and non-Markovian). Our results are in good agreement with Langevin dynamics simulations.

  14. Thermalization calorimetry: A simple method for investigating glass transition and crystallization of supercooled liquids

    Directory of Open Access Journals (Sweden)

    Bo Jakobsen

    2016-05-01

    Full Text Available We present a simple method for fast and cheap thermal analysis on supercooled glass-forming liquids. This “Thermalization Calorimetry” technique is based on monitoring the temperature and its rate of change during heating or cooling of a sample for which the thermal power input comes from heat conduction through an insulating material, i.e., is proportional to the temperature difference between sample and surroundings. The monitored signal reflects the sample’s specific heat and is sensitive to exo- and endothermic processes. The technique is useful for studying supercooled liquids and their crystallization, e.g., for locating the glass transition and melting point(s, as well as for investigating the stability against crystallization and estimating the relative change in specific heat between the solid and liquid phases at the glass transition.

  15. A fast, simple method for screening radiation susceptibility genes by RNA interference

    International Nuclear Information System (INIS)

    Tsuji, Atsushi B.; Sudo, Hitomi; Sugyo, Aya; Otsuki, Marika; Miyagishi, Makoto; Taira, Kazunari; Imai, Takashi; Harada, Yoshi-nobu

    2005-01-01

    Radiotherapy can cause unacceptable levels of damage to normal tissues in some cancer patients. To understand the molecular mechanisms underlying radiation-induced physiological responses, and to be able to predict the radiation susceptibility of normal tissues in individual patients, it is important to identify a comprehensive set of genes responsible for radiation susceptibility. We have developed a simple and rapid 96-well screening protocol using cell proliferation assays and RNA interference to identify genes associated with radiation susceptibility. We evaluated the performance of alamarBlue-, BrdU-, and sulforhodamine B-based cell proliferation assays using the 96-well format. Each proliferation assay detected the known radiation susceptibility gene, PRKDC. In a trial screen using 28 shRNA vectors, another known gene, CDKN1A, and one new radiation susceptibility gene, ATP5G3, were identified. Our results indicate that this method may be useful for large-scale screens designed to identify novel radiation susceptibility genes

  16. Simple method for the determination of 210Pb and 226Ra in waters

    International Nuclear Information System (INIS)

    Canoba, Analia C.; Gnoni, Gabriela A.

    2006-01-01

    In this work a method for the separation is described and the determination of the radionuclides 226 Ra and 210 Pb in samples of environmental waters. The determination of 210 Pb consists in how the precipitation of PbSO 4 (lead sulfate) and the measurement by liquid scintillation. The determination of 226 Ra is made for co-precipitation with BaSO 4 (barium sulfate), emanation of 222 Rn in toluene and its measurement by liquid scintillation. Both processes are fast, simple and they utilize accessible reagents and of low cost. In the case of the determination of 210 Pb, the parameters related to the separation and measurement was optimized. In the case of the decision of 226 Ra, was considered the technique already utilized by the laboratory for the measurements of this radionuclide. (author) [es

  17. Application of simple approximate system analysis methods for reliability and availability improvement of reactor WWER-1000

    International Nuclear Information System (INIS)

    Manchev, B.; Marinova, B.; Nenkova, B.

    2001-01-01

    The method described on this report provides a set of simple, easily understood 'approximate' models applicable to a large class of system architectures. Constructing a Markov model of each redundant subsystem and its replacement after that by a pseudo-component develops the approximation models. Of equal importance, the models can be easily understood even of non-experts, including managers, high-level decision-makers and unsophisticated consumers. A necessary requirement for their application is the systems to be repairable and the mean time to repair to be much smaller than the mean time to failure. This ia a case most often met in the real practice. Results of the 'approximate' model application on a technological system of Kozloduy NPP are also presented. The results obtained can be compared quite favorably with the results obtained by using SAPHIRE software

  18. Few-layer graphene growth from polystyrene as solid carbon source utilizing simple APCVD method

    Science.gov (United States)

    Ahmadi, Shahrokh; Afzalzadeh, Reza

    2016-07-01

    This research article presents development of an economical, simple, immune and environment friendly process to grow few-layer graphene by controlling evaporation rate of polystyrene on copper foil as catalyst and substrate utilizing atmospheric pressure chemical vapor deposition (APCVD) method. Evaporation rate of polystyrene depends on molecular structure, amount of used material and temperature. We have found controlling rate of evaporation of polystyrene by controlling the source temperature is easier than controlling the material weight. Atomic force microscopy (AFM) as well as Raman Spectroscopy has been used for characterization of the layers. The frequency of G‧ to G band ratio intensity in some samples varied between 0.8 and 1.6 corresponding to few-layer graphene. Topography characterization by atomic force microscopy confirmed Raman results.

  19. Structural characterization of pure and doped calcium phosphate bioceramics prepared by simple solid state method

    International Nuclear Information System (INIS)

    Ahmed, S.; Kabir, H.; Nigar, F.

    2011-01-01

    Calcium Phosphate based bioceramic materials, in pure and doped forms have been successfully synthesized from egg shells by using solid-state method for the first time. Considering the diverse role of zinc and fluoride in biological functions, these two ions were chosen to develop the substituted bioceramic materials. Structural characterizations of these developed bioceramics were performed by using FTIR, XRD, SEM and EDS techniques. The results revealed that the fluoride doped apatite was formed in single phase containing hydroxyapatite while pure and Zinc doped apatites contained -TCP with hydroxyapatite. Experimental results and the crystallographic parameters matched well with the literature values indicating that the present experimental protocol favoured the formation of the desired bioceramics. However, to synthesize the (Ca (PO)) based bioceramic materials, such a simple solid-state approach would obviously be very helpful, not only in making the process economically feasible, but also in creating an effective material recycling technology for waste-management. (author)

  20. A simple, scalable and low-cost method to generate thermal diagnostics of a domestic building

    International Nuclear Information System (INIS)

    Papafragkou, Anastasios; Ghosh, Siddhartha; James, Patrick A.B.; Rogers, Alex; Bahaj, AbuBakr S.

    2014-01-01

    Highlights: • Our diagnostic method uses a single field measurement from a temperature logger. • Building technical performance and occupant behaviour are addressed simultaneously. • Our algorithm learns a thermal model of a home and diagnoses the heating system. • We propose a novel clustering approach to decouple user behaviour from technical performance. • Our diagnostic confidence is enhanced using a large scale deployment. - Abstract: Traditional approaches to understand the problem of the energy performance in the domestic sector include on-site surveys by energy assessors and the installation of complex home energy monitoring systems. The time and money that needs to be invested by the occupants and the form of feedback generated by these approaches often makes them unattractive to householders. This paper demonstrates a simple, low cost method that generates thermal diagnostics for dwellings, measuring only one field dataset; internal temperature over a period of 1 week. A thermal model, which is essentially a learning algorithm, generates a set of thermal diagnostics about the primary heating system, the occupants’ preferences and the impact of certain interventions, such as lowering the thermostat set-point. A simple clustering approach is also proposed to categorise homes according to their building fabric thermal performance and occupants’ energy efficiency with respect to ventilation. The advantage of this clustering approach is that the occupants receive tailored advice on certain actions that if taken will improve the overall thermal performance of a dwelling. Due to the method’s low cost and simplicity it could facilitate government initiatives, such as the ‘Green Deal’ in the UK

  1. Simple method for the determination of rosiglitazone in human plasma using a commercially available internal standard.

    Science.gov (United States)

    Mamidi, Rao N V S; Benjamin, Biju; Ramesh, Mullangi; Srinivas, Nuggehally R

    2003-09-01

    To the best of our knowledge, bioanalytical methods to determine rosiglitazone in human plasma reported in literature use internal standards that are not commercially available. Our purpose was to develop a simple method for the determination of rosiglitazone in plasma employing a commercially available internal standard (IS). After the addition of celecoxib (IS), plasma (0.25 mL) samples were extracted into ethyl acetate. The residue after evaporation of the organic layer was dissolved in 750 microL of mobile phase and 50 microL was injected on to HPLC. The separation was achieved using a Hichrom KR 100, 250 x 4.6 mm C(18) with a mobile phase composition potassium dihydrogen phosphate buffer (0.01 m, pH 6.5):acetonitrile:methanol (40:50:10, v/v/v). The flow-rate of the mobile phase was set at 1 mL/min. The column eluate was monitored by fluorescence detector set at an excitation wavelength of 247 nm and emission wavelength of 367 nm. Linear relationships (r(2) > 0.99) were observed between the peak area ratio rosiglitazone to IS vs rosiglitazone concentrations across the concentration range 5-1000 ng/mL. The intra-run precision (%RSD) and accuracy (%Dev) in the measurement of rosiglitazone were 80% for both rosiglitazone and IS from human plasma. The lower limit of quantitation of the assay was 5 ng/mL. In summary, the methodology for rosiglitazone measurement in plasma was simple, sensitive and employed a commercially available IS. Copyright 2003 John Wiley & Sons, Ltd.

  2. Prostate cancer diagnosis: Efficacy of a simple electromagnetic MRI-TRUS fusion method to target biopsies

    International Nuclear Information System (INIS)

    Jelidi, Amina; Ohana, Mickael; Labani, Aïssam; Alemann, Guillaume; Lang, Herve; Roy, Catherine

    2017-01-01

    Highlights: • A very simple electromagnetic device for fusion with MRI examination during TRUS guided biopsies increases the detection of clinically significant prostate cancer. • This device has advantages: a short time for the fusion registration, no additional cumbersome material and no intense training to be fluent with. • Low or intermediate suspicious area for prostate carcinoma on mpMRI can be due to benign histological abnormalities or high grade prostatic intraepithelial neoplasia. - Abstract: Objective: To assess that transrectal ultrasound guidance (TRUS) targeted biopsies (TB) aimed with an easy to use electronic real-time fusion registration device have a higher rate of prostate cancer (PC) detection than standard biopsies (SB). Material and methods: This prospective study included 130 patients referred for TRUS biopsies after suspicious MRI. They underwent 16-core SB and 2 to 3 cores in each MRI suspicious area, using a fusion software. We noted SB and TB positivity for PC and Gleason score (GS). We used the McNemar test to compare SB and TB, with a statistical significance p < 0.05. Results: Among 130 patients, 68.5% had PC. Additional time due to the fusion registration was 3.3 min. One hundred fifteen patients (88.4%) had pathological findings on the histological analysis (prostate cancer n = 89, others n = 26). TB diagnosed PC in 75 patients with negative SB. Positivity rate for PC was significantly higher for TB than SB (p = 0.03). Among highly suspicious MRI lesions, detection rate of histological abnormalities using SB and TB was 96% with 79.7% of PC. Most PC that TB diagnosed alone were clinically significant (86.3%). Conclusion: TRUS biopsies performed with a simple MRI and US electronic fusion is an unrestrainedly method to increase PC diagnosis.

  3. Simple spectrophotometry method for the determination of sulfur dioxide in an alcohol-thionyl chloride reaction

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Jinjian, E-mail: jinjian.zheng@merck.com; Tan, Feng; Hartman, Robert

    2015-09-03

    Thionyl chloride is often used to convert alcohols into more reactive alkyl chloride, which can be easily converted to many compounds that are not possible from alcohols directly. One important reaction of alkyl chloride is nucleophilic substitution, which is typically conducted under basic conditions. Sulfur dioxide, the by-product from alcohol-thionyl chloride reactions, often reacts with alkyl chloride to form a sulfonyl acid impurity, resulting in yield loss. Therefore, the alkyl chloride is typically isolated to remove the by-products including sulfur dioxide. However, in our laboratory, the alkyl chloride formed from alcohol and thionyl chloride was found to be a potential mutagenic impurity, and isolation of this compound would require extensive safety measures. As a result, a flow-through process was developed, and the sulfur dioxide was purged using a combination of vacuum degassing and nitrogen gas sweeping. An analytical method that can quickly and accurately quantitate residual levels of sulfur dioxide in the reaction mixture is desired for in-process monitoring. We report here a simple ultraviolet (UV) spectrophotometry method for this measurement. This method takes advantage of the dramatic change in the UV absorbance of sulfur dioxide with respect to pH, which allows for accurate quantitation of sulfur dioxide in the presence of the strong UV-absorbing matrix. Each sample solution was prepared using 2 different diluents: 1) 50 mM ammonium acetate in methanol +1% v/v hydrochloric acid, pH 1.3, and 2) 50 mM ammonium acetate in methanol +1% glacial acetic acid, pH 4.0. The buffer solutions were carefully selected so that the UV absorbance of the sample matrix (excluding sulfur dioxide) at 276 nm remains constant. In the pH 1.3 buffer system, sulfur dioxide shows strong UV absorbance at 276 nm. Therefore, the UV absorbance of sample solution is the sum of sulfur dioxide and sample matrix. While in the pH 4.0 buffer system, sulfur dioxide has

  4. Simple analytical technique for liquid scintillation counting of environmental carbon-14 using gel suspension method

    International Nuclear Information System (INIS)

    Okai, Tomio; Wakabayashi, Genichiro; Nagao, Kenjiro; Matoba, Masaru; Ohura, Hirotaka; Momoshima, Noriyuki; Kawamura, Hidehisa

    2000-01-01

    A simple analytical technique for liquid scintillation counting of environmental 14 C was developed. Commercially available gelling agent, N-lauroyl-L -glutamic -α,γ-dibutylamide, was used for the gel-formation of the samples (gel suspension method) and for the subsequent liquid scintillation counting of 14 C in the form of CaCO 3 . Our procedure for sample preparation is much simpler than that of the conventional methods and requires no special equipment. Self absorption, stability and reproducibility of gel suspension samples were investigated in order to evaluate the characteristics of the gel suspension method for 14 C activity measurement. The self absorption factor is about 70% and slightly decrease as CaCO 3 weight increase. This is considered to be mainly due to the absorption of β-rays and scintillation light by the CaCO 3 sample itself. No change of the counting rate for the gel suspension sample was observed for more than 2 years after the sample preparation. Four samples were used for checking the reproducibility of the sample preparation method. The same values were obtained for the counting rate of 24 C activity within the counting error. No change of the counting rate was observed for the 're-gelated' sample. These results show that the gel suspension method is appropriate for the 14 C activity measurement by the liquid scintillation counting method and useful for a long-term preservation of the sample for repeated measurement. The above analytical technique was applied to actual environmental samples in Fukuoka prefecture, Japan. Results obtained were comparable with those by other researchers and appear to be reasonable. Therefore, the newly developed technique is useful for the routine monitoring of environmental 14 C. (author)

  5. Sensitive radioimmunoassay of total thyroxine (T4) in horses using a simple extraction method.

    Science.gov (United States)

    Tangyuenyong, Siriwan; Nambo, Yasuo; Nagaoka, Kentaro; Tanaka, Tomomi; Watanabe, Gen

    2017-07-28

    Most thyroid hormone determinations in animals are based on immunoassays adapted from those used to test human samples, which may not reflect the actual values of thyroid hormone in horses because of the presence of binding proteins. The aims of the present study were i) to establish a novel radioimmunoassay (RIA) using a more simple and convenient method to separate binding proteins for the measurement of total thyroxine (T4) in horses and ii) to validate the assay by comparing total T4 concentrations in yearling horses raised in different climates. Blood samples were collected from trained yearlings in Hokkaido (temperate climate) and Miyazaki (subtropical climate) in Japan and from adult horses in estrus and diestrus. T4 was extracted from both serum and plasma using modified acid ethanol cryo-precipitation and sodium acetate ethanol methods. Circulating total T4 concentrations were determined by RIA. T4 concentration by sodium acetate ethanol was appropriately detectable rather than sodium salicylate method and was the same as for acid ethanol method. Furthermore, this sodium acetate ethanol method required fewer extraction steps than the other methods. Circulating T4 concentrations in yearlings were 225.98 ± 20.89 ng/ml, which was higher than the previous reference values. With respect to climate, T4 levels in Hokkaido yearlings tended to be higher than those in Miyazaki yearlings throughout the study period. These results indicated that this RIA protocol using a modified sodium acetate ethanol separation technique might be an appropriate tool for specific measurement of total T4 in horses.

  6. Deployment Analysis of a Simple Tape-Spring Hinge Using Probabilistic Methods

    Science.gov (United States)

    Lyle, Karen H.; Horta, Lucas G.

    2012-01-01

    Acceptance of new deployable structures architectures and concepts requires validated design methods to minimize the expense involved with technology validation flight testing. Deployable concepts for large lightweight spacecraft include booms, antennae, and masts. This paper explores the implementation of probabilistic methods in the design process for the deployment of a strain-energy mechanism, specifically a simple tape-spring hinge. Strain-energy mechanisms are attractive for deployment in very lightweight systems because they do not require the added mass and complexity associated with motors and controllers. However, designers are hesitant to include free deployment, strain-energy mechanisms because of the potential for uncontrolled behavior. In the example presented here, the tapespring cross-sectional dimensions have been varied and a target displacement during deployment has been selected as the design metric. Specifically, the tape-spring should reach the final position in the shortest time with the minimal amount of overshoot and oscillations. Surrogate models have been used to reduce computational expense. Parameter values to achieve the target response have been computed and used to demonstrate the approach. Based on these results, the application of probabilistic methods for design of a tape-spring hinge has shown promise as a means of designing strain-energy components for more complex space concepts.

  7. A Simple PCR Method for Rapid Genotype Analysis of Mycobacterium ulcerans

    Science.gov (United States)

    Stinear, Timothy; Davies, John K.; Jenkin, Grant A.; Portaels, Françoise; Ross, Bruce C.; OppEdIsano, Frances; Purcell, Maria; Hayman, John A.; Johnson, Paul D. R.

    2000-01-01

    Two high-copy-number insertion sequences, IS2404 and IS2606, were recently identified in Mycobacterium ulcerans and were shown by Southern hybridization to possess restriction fragment length polymorphism between strains from different geographic origins. We have designed a simple genotyping method that captures these differences by PCR amplification of the region between adjacent copies of IS2404 and IS2606. We have called this system 2426 PCR. The method is rapid, reproducible, sensitive, and specific for M. ulcerans, and it has confirmed previous studies suggesting a clonal population structure of M. ulcerans within a geographic region. M. ulcerans isolates from Australia, Papua New Guinea, Malaysia, Surinam, Mexico, Japan, China, and several countries in Africa were easily differentiated based on an array of 4 to 14 PCR products ranging in size from 200 to 900 bp. Numerical analysis of the banding patterns suggested a close evolutionary link between M. ulcerans isolates from Africa and southeast Asia. The application of 2426 PCR to total DNA, extracted directly from M. ulcerans-infected tissue specimens without culture, demonstrated the sensitivity and specificity of this method and confirmed for the first time that both animal and human isolates from areas of endemicity in southeast Australia have the same genotype. PMID:10747130

  8. A simple method of digitizing analog scintigrams for quantification and digital archiving

    International Nuclear Information System (INIS)

    Schramm, M.; Kaempfer, B.; Wolf, H.; Clausen, M.; Wendhausen, H.; Henze, E.

    1993-01-01

    This study was undertaken to evaluate a quick, reliable and cheap method of digitizing analog scintigrams. 40 whole-body bone scintigrams were obtained simultaneously in analog and genuine digital format. The analog scans on X-ray film were then digitized seecondarily by three different methods: 300 dpi flatbed scanning, high-resolution camera scanning and camcorder recording. A simple exposure approach using a light box, a cheap camcorder, a PC and image grabber hard- and software proved to be optimal. Visual interpretation showed no differences in clinical findings when comparing the analog images with their secondarily digitized counterparts. To test the possibility of quantification, 126 equivalent ROIs were drawn both in the genuine digital and the secondarily digitized images. Comparing the ROI count to whole-body count percentage of the corresponding ROIs showed the correlation to be linear. The evaluation of phantom studies showed the linear correlation to be true within a wide activity range. Thus, secondary digitalization of analog scintigrams is an easy, cheap and reliable method of archiving images and allows secondary digital quantification. (orig.) [de

  9. Evaluation of ductile tearing in a cracked component with a simple method (Js)

    International Nuclear Information System (INIS)

    Moulin, D.; Drubay, B.; Clement, G.; Nedelec, M.

    1995-01-01

    In the nuclear industry, it is more and more usual to perform fracture assessment on detective structures made of ductile material with the help of elastoplastic' fracture mechanics relying on the parameter J. Several engineering methods have been developed in the past to calculate this parameter. These results were used to develop a practical procedure noted Js method which simply gives J as function of elastically calculated Je and a plastic correction factor. This method has been introduced in the A16 rule developed jointly by CEA-EdF and Novatome for fast breeder reactors in particular in order to evaluate the loading at crack instability taking into a account ductile tearing. The determination of initiation has already been presented. This determination of the loading at crack instability is examined through two simple but representative examples using the simplified estimation of J. Predicted loadings at crack instability are compared with experimental results. This study was carried out a part of cooperative program with the Institut de Protection et de Surete Nucleaire of the CEA. (author) 12 refs., 10 figs

  10. A simple and non-invasive method for nuclear transformation of intact-walled Chlamydomonas reinhardtii.

    Directory of Open Access Journals (Sweden)

    Sora Kim

    Full Text Available Genetic engineering in microalgae is gaining attraction but nuclear transformation methods available so far are either inefficient or require special equipment. In this study, we employ positively charged nanoparticles, 3-aminopropyl-functionalized magnesium phyllosilicate (aminoclay, approximate unit cell composition of [H2N(CH23]8Si8Mg6O12(OH4, for nuclear transformation into eukaryotic microalgae. TEM and EDX analysis of the process of transformation reveals that aminoclay coats negatively-charged DNA biomolecules and forms a self-assembled hybrid nanostructure. Subsequently, when this nanostructure is mixed with microalgal cells and plated onto selective agar plates with high friction force, cell wall is disrupted facilitating delivery of plasmid DNA into the cell and ultimately to the nucleus. This method is not only simple, inexpensive, and non-toxic to cells but also provides efficient transformation (5.03×10(2 transformants/µg DNA, second only to electroporation which needs advanced instrumentation. We present optimized parameters for efficient transformation including pre-treatment, friction force, concentration of foreign DNA/aminoclay, and plasticity of agar plates. It is also confirmed the successful integration and stable expression of foreign gene in Chlamydomonas reinhardtii through molecular methods.

  11. A simple method for estimating the size of nuclei on fractal surfaces

    Science.gov (United States)

    Zeng, Qiang

    2017-10-01

    Determining the size of nuclei on complex surfaces remains a big challenge in aspects of biological, material and chemical engineering. Here the author reported a simple method to estimate the size of the nuclei in contact with complex (fractal) surfaces. The established approach was based on the assumptions of contact area proportionality for determining nucleation density and the scaling congruence between nuclei and surfaces for identifying contact regimes. It showed three different regimes governing the equations for estimating the nucleation site density. Nuclei in the size large enough could eliminate the effect of fractal structure. Nuclei in the size small enough could lead to the independence of nucleation site density on fractal parameters. Only when nuclei match the fractal scales, the nucleation site density is associated with the fractal parameters and the size of the nuclei in a coupling pattern. The method was validated by the experimental data reported in the literature. The method may provide an effective way to estimate the size of nuclei on fractal surfaces, through which a number of promising applications in relative fields can be envisioned.

  12. Methods for estimating wake flow and effluent dispersion near simple block-like buildings

    International Nuclear Information System (INIS)

    Hosker, R.P. Jr.

    1981-05-01

    This report is intended as an interim guide for those who routinely face air quality problems associated with near-building exhaust stack placement and height, and the resulting concentration patterns. Available data and methods for estimating wake flow and effluent dispersion near isolated block-like structures are consolidated. The near-building and wake flows are described, and quantitative estimates for frontal eddy size, height and extent of roof and wake cavities, and far wake behavior are provided. Concentration calculation methods for upwind, near-building, and downwind pollutant sources are given. For an upwind source, it is possible to estimate the required stack height, and to place upper limits on the likely near-building concentration. The influences of near-building source location and characteristics relative to the building geometry and orientation are considered. Methods to estimate effective stack height, upper limits for concentration due to flush roof vents, and the effect of changes in rooftop stack height are summarized. Current wake and wake cavity models are presented. Numerous graphs of important expressions have been prepared to facilitate computations and quick estimates of flow patterns and concentration levels for specific simple buildings. Detailed recommendations for additional work are given

  13. Rapid, Simple, and Sensitive Spectrofluorimetric Method for the Estimation of Ganciclovir in Bulk and Pharmaceutical Formulations

    Directory of Open Access Journals (Sweden)

    Garima Balwani

    2013-01-01

    Full Text Available A new, simple, rapid, sensitive, accurate, and affordable spectrofluorimetric method was developed and validated for the estimation of ganciclovir in bulk as well as in marketed formulations. The method was based on measuring the native fluorescence of ganciclovir in 0.2 M hydrochloric acid buffer of pH 1.2 at 374 nm after excitation at 257 nm. The calibration graph was found to be rectilinear in the concentration range of 0.25–2.00 μg mL−1. The limit of quantification and limit of detection were found to be 0.029 μg mL−1 and 0.010 μg mL−1, respectively. The method was fully validated for various parameters according to ICH guidelines. The results demonstrated that the procedure is accurate, precise, and reproducible (relative standard deviation <2% and can be successfully applied for the determination of ganciclovir in its commercial capsules with average percentage recovery of 101.31 ± 0.90.

  14. IMPLEMENTATION OF SIMPLE ADDITIVE WEIGHTING (SAW METHODE IN DETERMINING HIGH SCHOOL STUDENT’S INTEREST

    Directory of Open Access Journals (Sweden)

    Prind Triajeng Pungkasanti

    2017-09-01

    Full Text Available The Ministry of Research, Technology, and Higher Education of Republic of Indonesia has set a regulation about curriculum applied in education field named Kurikulum 2013. One of the subsections in the Kurikulum 2013 regulates all requirements of majoring in high school. High school students determine their major based on Kurrikulum 2013 as they are on the 10th grade. The purpose of the majoring in education is to allow children development based on their skills and interests, because before, majoring have been done based on scores obtained. The main problem is the majoring requirements considered are admission test score and Junior High School National Test score. Both scores are not sufficient enough to determine the students major therefore academic aptitude test score is required. In term of weighting, the school has not been imposed the weighting system so the scores obtained is the average of admission test score and national test score. Based on the issue above, a solution required to solve the issue using a method. Method used in this research is Simple Additive Weighting (SAW, wherein this methode is looking for the weighted sum of performance rate on every alternative of atributes. This research provides the information about which potential students is suitable to enter the science major and social major so this results can be used as consideration of school decisions.

  15. A simple and efficient method of nickel electrodeposition for the cyclotron production of 64Cu

    International Nuclear Information System (INIS)

    Manrique-Arias, Juan C.; Avila-Rodriguez, Miguel A.

    2014-01-01

    Nickel targets for the cyclotron production of 64 Cu were prepared by electrodeposition on a gold backing from nickel chloride solutions using boric acid as buffer. Parameters studied were nickel chloride and boric acid concentration, temperature and current density. All plating conditions studied were successful obtaining efficiencies of approximately 90% in 2–3 h, reaching almost quantitative plating (>97%) in 10–20 h depending on the current density. All plated targets withstood proton irradiations up to 40 µA for 2 h. Recovered nickel was successfully recycled and reused with an overall efficiency >95%. - Highlights: • Simple and efficient method of Ni electrodeposition from NiCl 2 solutions. • Represents an improvement over current methods for the preparation of Ni targets. • All plated targets underwent irradiation and withstood currents up to 40 µA for 2 h. • Nickel target material was recycled and reused with an overall efficiency >95%. • Specific activity of 64 Cu was similar than that obtained with older methods of Ni plating

  16. [A simple method of digitizing analog scintigrams for quantification and digital archiving].

    Science.gov (United States)

    Schramm, M; Kämpfer, B; Wolf, H; Clausen, M; Wendhausen, H; Henze, E

    1993-02-01

    This study was undertaken to evaluate a quick, reliable and cheap method of digitizing analog scintigrams. 40 whole-body bone scintigrams were obtained simultaneously in analog and genuine digital format. The analog scans on x-ray film were then digitized secondarily by three different methods: 300 dpi flat-bed scanning, high-resolution camera scanning and camcorder recording. A simple exposure approach using a light box, a cheap camcorder, a PC and image grabber hard- and software proved to be optimal. Visual interpretation showed no differences in clinical findings when comparing the analog images with their secondarily digitized counterparts. To test the possibility of quantification, 126 equivalent ROIs were drawn both in the genuine digital and the secondarily digitized images. Comparing the ROI count to whole-body count percentage of the corresponding ROIs showed the correlation to be linear. The evaluation of phantom studies showed the linear correlation to be true within a wide activity range. Thus, secondary digitalization of analog scintigrams is an easy, cheap and reliable method of archiving images and allows secondary digital quantification.

  17. A simple method for finding explicit analytic transition densities of diffusion processes with general diploid selection.

    Science.gov (United States)

    Song, Yun S; Steinrücken, Matthias

    2012-03-01

    The transition density function of the Wright-Fisher diffusion describes the evolution of population-wide allele frequencies over time. This function has important practical applications in population genetics, but finding an explicit formula under a general diploid selection model has remained a difficult open problem. In this article, we develop a new computational method to tackle this classic problem. Specifically, our method explicitly finds the eigenvalues and eigenfunctions of the diffusion generator associated with the Wright-Fisher diffusion with recurrent mutation and arbitrary diploid selection, thus allowing one to obtain an accurate spectral representation of the transition density function. Simplicity is one of the appealing features of our approach. Although our derivation involves somewhat advanced mathematical concepts, the resulting algorithm is quite simple and efficient, only involving standard linear algebra. Furthermore, unlike previous approaches based on perturbation, which is applicable only when the population-scaled selection coefficient is small, our method is nonperturbative and is valid for a broad range of parameter values. As a by-product of our work, we obtain the rate of convergence to the stationary distribution under mutation-selection balance.

  18. A simple and rapid method for high-resolution visualization of single-ion tracks

    Directory of Open Access Journals (Sweden)

    Masaaki Omichi

    2014-11-01

    Full Text Available Prompt determination of spatial points of single-ion tracks plays a key role in high-energy particle induced-cancer therapy and gene/plant mutations. In this study, a simple method for the high-resolution visualization of single-ion tracks without etching was developed through the use of polyacrylic acid (PAA-N, N’-methylene bisacrylamide (MBAAm blend films. One of the steps of the proposed method includes exposure of the irradiated films to water vapor for several minutes. Water vapor was found to promote the cross-linking reaction of PAA and MBAAm to form a bulky cross-linked structure; the ion-track scars were detectable at a nanometer scale by atomic force microscopy. This study demonstrated that each scar is easily distinguishable, and the amount of generated radicals of the ion tracks can be estimated by measuring the height of the scars, even in highly dense ion tracks. This method is suitable for the visualization of the penumbra region in a single-ion track with a high spatial resolution of 50 nm, which is sufficiently small to confirm that a single ion hits a cell nucleus with a size ranging between 5 and 20 μm.

  19. A simple method to prepare magnetic modified beer yeast and its application for cationic dye adsorption.

    Science.gov (United States)

    Yu, Jun-Xia; Wang, Li-Yan; Chi, Ru-An; Zhang, Yue-Fei; Xu, Zhi-Gao; Guo, Jia

    2013-01-01

    The purpose of this research is to use a simple method to prepare magnetic modified biomass with good adsorption performances for cationic ions. The magnetic modified biomass was prepared by two steps: (1) preparation of pyromellitic dianhydride (PMDA) modified biomass in N, N-dimethylacetamide solution and (2) preparation of magnetic PMDA modified biomass by a situ co-precipitation method under the assistance of ultrasound irradiation in ammonia water. The adsorption potential of the as-prepared magnetic modified biomass was analyzed by using cationic dyes: methylene blue and basic magenta as model dyes. Optical micrograph and x-ray diffraction analyses showed that Fe(3)O(4) particles were precipitated on the modified biomass surface. The as-prepared biosorbent could be recycled easily by using an applied magnetic field. Titration analysis showed that the total concentration of the functional groups on the magnetic PMDA modified biomass was calculated to be 0.75 mmol g(-1) by using the first derivative method. The adsorption capacities (q(m)) of the magnetic PMDA modified biomass for methylene blue and basic magenta were 609.0 and 520.9 mg g(-1), respectively, according to the Langmuir equation. Kinetics experiment showed that adsorption could be completed within 150 min for both dyes. The desorption experiment showed that the magnetic sorbent could be used repeatedly after regeneration. The as-prepared magnetic modified sorbent had a potential in the dyeing industry wastewater treatment.

  20. Oral histories: a simple method of assigning chronological age to isotopic values from human dentine collagen.

    Science.gov (United States)

    Beaumont, Julia; Montgomery, Janet

    2015-01-01

    Stable isotope ratios of carbon (δ(13)C) and nitrogen (δ(15)N) in bone and dentine collagen have been used for over 30 years to estimate palaeodiet, subsistence strategy, breastfeeding duration and migration within burial populations. Recent developments in dentine microsampling allow improved temporal resolution for dietary patterns. A simple method is proposed which could be applied to human teeth to estimate chronological age represented by dentine microsamples in the direction of tooth growth, allowing comparison of dietary patterns between individuals and populations. The method is tested using profiles from permanent and deciduous teeth of two individuals. Using a diagrammatic representation of dentine development by approximate age for each human tooth (based on the Queen Mary University of London Atlas), this study estimated the age represented by each dentine section. Two case studies are shown: comparison of M1 and M2 from a 19th century individual from London, England, and identification of an unknown tooth from an Iron Age female adult from Scotland. The isotopic profiles demonstrate that variations in consecutively-forming teeth can be aligned using this method to extend the dietary history of an individual or identify an unknown tooth by matching the profiles.

  1. Evaluation of radiation shielding performance in sea transport of radioactive material by using simple calculation method

    International Nuclear Information System (INIS)

    Odano, N.; Ohnishi, S.; Sawamura, H.; Tanaka, Y.; Nishimura, K.

    2004-01-01

    A modified code system based on the point kernel method was developed to use in evaluation of shielding performance for maritime transport of radioactive material. For evaluation of shielding performance accurately in the case of accident, it is required to preciously model the structure of transport casks and shipping vessel, and source term. To achieve accurate modelling of the geometry and source term condition, we aimed to develop the code system by using equivalent information regarding structure and source term used in the Monte Carlo calculation code, MCNP. Therefore, adding an option to use point kernel method to the existing Monte Carlo code, MCNP4C, the code system was developed. To verify the developed code system, dose rate distribution in an exclusive shipping vessel to transport the low level radioactive wastes were calculated by the developed code and the calculated results were compared with measurements and Monte Carlo calculations. It was confirmed that the developed simple calculation method can obtain calculation results very quickly with enough accuracy comparing with the Monte Carlo calculation code MCNP4C

  2. A simple and rapid method for high-resolution visualization of single-ion tracks

    Energy Technology Data Exchange (ETDEWEB)

    Omichi, Masaaki [Department of Applied Chemistry, Graduate School of Engineering, Osaka University, Osaka 565-0871 (Japan); Center for Collaborative Research, Anan National College of Technology, Anan, Tokushima 774-0017 (Japan); Choi, Wookjin; Sakamaki, Daisuke; Seki, Shu, E-mail: seki@chem.eng.osaka-u.ac.jp [Department of Applied Chemistry, Graduate School of Engineering, Osaka University, Osaka 565-0871 (Japan); Tsukuda, Satoshi [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, Sendai, Miyagi 980-8577 (Japan); Sugimoto, Masaki [Japan Atomic Energy Agency, Takasaki Advanced Radiation Research Institute, Gunma, Gunma 370-1292 (Japan)

    2014-11-15

    Prompt determination of spatial points of single-ion tracks plays a key role in high-energy particle induced-cancer therapy and gene/plant mutations. In this study, a simple method for the high-resolution visualization of single-ion tracks without etching was developed through the use of polyacrylic acid (PAA)-N, N’-methylene bisacrylamide (MBAAm) blend films. One of the steps of the proposed method includes exposure of the irradiated films to water vapor for several minutes. Water vapor was found to promote the cross-linking reaction of PAA and MBAAm to form a bulky cross-linked structure; the ion-track scars were detectable at a nanometer scale by atomic force microscopy. This study demonstrated that each scar is easily distinguishable, and the amount of generated radicals of the ion tracks can be estimated by measuring the height of the scars, even in highly dense ion tracks. This method is suitable for the visualization of the penumbra region in a single-ion track with a high spatial resolution of 50 nm, which is sufficiently small to confirm that a single ion hits a cell nucleus with a size ranging between 5 and 20 μm.

  3. Fuzzy Simple Additive Weighting Method in the Decision Making of Human Resource Recruitment

    Directory of Open Access Journals (Sweden)

    Budi Prasetiyo

    2016-12-01

    Full Text Available The Company is one of the jobs that was founded to reduce unemployment. The progress of a company is determined by the human resources that exist within the company. So, the selection of workers will join the company need to be selected first. The hardest thing in making a selection factor is the effort to eliminate the subjectivity of the personnel manager so that every choice made is objective based on the criteria expected by the company. To help determine who is accepted as an employee in the company, we need a method that can provide a valid decision. Therefore, we use Fuzzy Multiple Attribute Decision Making with Simple Additive Weighting method (SAW to decide to make in human resource recruitment. This method was chosen because it can provide the best alternative from several alternatives. In this case, the alternative is that the applicants or candidates. This research was conducted by finding the weight values for each attribute. Then do the ranking process that determines the optimal alternative to the best applicants who qualify as employees of the company. Based on calculations by the SAW obtained the two highest ranking results are A5 (alternative 5 and A1 (alternative 1, to obtain two candidates received.

  4. Limited hair cell induction from human induced pluripotent stem cells using a simple stepwise method.

    Science.gov (United States)

    Ohnishi, Hiroe; Skerleva, Desislava; Kitajiri, Shin-ichiro; Sakamoto, Tatsunori; Yamamoto, Norio; Ito, Juichi; Nakagawa, Takayuki

    2015-07-10

    Disease-specific induced pluripotent stem cells (iPS) cells are expected to contribute to exploring useful tools for studying the pathophysiology of inner ear diseases and to drug discovery for treating inner ear diseases. For this purpose, stable induction methods for the differentiation of human iPS cells into inner ear hair cells are required. In the present study, we examined the efficacy of a simple induction method for inducing the differentiation of human iPS cells into hair cells. The induction of inner ear hair cell-like cells was performed using a stepwise method mimicking inner ear development. Human iPS cells were sequentially transformed into the preplacodal ectoderm, otic placode, and hair cell-like cells. As a first step, preplacodal ectoderm induction, human iPS cells were seeded on a Matrigel-coated plate and cultured in a serum free N2/B27 medium for 8 days according to a previous study that demonstrated spontaneous differentiation of human ES cells into the preplacodal ectoderm. As the second step, the cells after preplacodal ectoderm induction were treated with basic fibroblast growth factor (bFGF) for induction of differentiation into otic-placode-like cells for 15 days. As the final step, cultured cells were incubated in a serum free medium containing Matrigel for 48 days. After preplacodal ectoderm induction, over 90% of cultured cells expressed the genes that express in preplacodal ectoderm. By culture with bFGF, otic placode marker-positive cells were obtained, although their number was limited. Further 48-day culture in serum free media resulted in the induction of hair cell-like cells, which expressed a hair cell marker and had stereocilia bundle-like constructions on their apical surface. Our results indicate that hair cell-like cells are induced from human iPS cells using a simple stepwise method with only bFGF, without the use of xenogeneic cells. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  5. Variability in clinical data is often more useful than the mean: illustration of concept and simple methods of assessment

    NARCIS (Netherlands)

    Zwinderman, A. H.; Cleophas, T. J.

    2005-01-01

    BACKGROUND: Clinical investigators, although they are generally familiar with testing differences between averages, have difficulty testing differences between variabilities. OBJECTIVE: To give examples of situations where variability is more relevant than averages and to describe simple methods for

  6. SIMPLE METHOD FOR THE EXTRACTION OF PHOTOPIGMENTS AND MYCOSPORINE-LIKE AMINO ACIDS (MAAS) FROM SYMBIODINIUM SPP.

    Science.gov (United States)

    Numerous extraction methods have been developed and used in the quantitation of both photopigments and mycosporine amino acids (MAAs) found in Symbiodinium sp. and zooanthellate metazoans. We have development of a simple, mild extraction procedure using methanol, which when coupl...

  7. A Simple and Efficient Numerical Method for Computing the Dynamics of Rotating Bose--Einstein Condensates via Rotating Lagrangian Coordinates

    KAUST Repository

    Bao, Weizhu; Marahrens, Daniel; Tang, Qinglin; Zhang, Yanzhi

    2013-01-01

    We propose a simple, efficient, and accurate numerical method for simulating the dynamics of rotating Bose-Einstein condensates (BECs) in a rotational frame with or without longrange dipole-dipole interaction (DDI). We begin with the three

  8. Generating Lie Point Symmetry Groups of (2+1)-Dimensional Broer-Kaup Equation via a Simple Direct Method

    International Nuclear Information System (INIS)

    Ma Hongcai

    2005-01-01

    Using the (2+1)-dimensional Broer-Kaup equation as an simple example, a new direct method is developed to find symmetry groups and symmetry algebras and then exact solutions of nonlinear mathematical physical equations.

  9. Control of the large renal vein in limited dissected space during laparoscopic nephrectomy: a simple and reliable method

    NARCIS (Netherlands)

    Kijvikai, Kittinut; Laguna, M. Pilar; de la Rosette, Jean

    2006-01-01

    We describe our technique for large renal vein control in the limited dissected space during laparoscopic nephrectomy. This technique is a simple, inexpensive and reliable method, especially for large and short renal vein ligation

  10. Development and validation of a simple method for the extraction of human skin melanocytes.

    Science.gov (United States)

    Wang, Yinjuan; Tissot, Marion; Rolin, Gwenaël; Muret, Patrice; Robin, Sophie; Berthon, Jean-Yves; He, Li; Humbert, Philippe; Viennet, Céline

    2018-03-21

    Primary melanocytes in culture are useful models for studying epidermal pigmentation and efficacy of melanogenic compounds, or developing advanced therapy medicinal products. Cell extraction is an inevitable and critical step in the establishment of cell cultures. Many enzymatic methods for extracting and growing cells derived from human skin, such as melanocytes, are described in literature. They are usually based on two enzymatic steps, Trypsin in combination with Dispase, in order to separate dermis from epidermis and subsequently to provide a suspension of epidermal cells. The objective of this work was to develop and validate an extraction method of human skin melanocytes being simple, effective and applicable to smaller skin samples, and avoiding animal reagents. TrypLE™ product was tested on very limited size of human skin, equivalent of multiple 3-mm punch biopsies, and was compared to Trypsin/Dispase enzymes. Functionality of extracted cells was evaluated by analysis of viability, morphology and melanin production. In comparison with Trypsin/Dispase incubation method, the main advantages of TrypLE™ incubation method were the easier of separation between dermis and epidermis and the higher population of melanocytes after extraction. Both protocols preserved morphological and biological characteristics of melanocytes. The minimum size of skin sample that allowed the extraction of functional cells was 6 × 3-mm punch biopsies (e.g., 42 mm 2 ) whatever the method used. In conclusion, this new procedure based on TrypLE™ incubation would be suitable for establishment of optimal primary melanocytes cultures for clinical applications and research.

  11. A simple method for identifying parameter correlations in partially observed linear dynamic models.

    Science.gov (United States)

    Li, Pu; Vu, Quoc Dong

    2015-12-14

    Parameter estimation represents one of the most significant challenges in systems biology. This is because biological models commonly contain a large number of parameters among which there may be functional interrelationships, thus leading to the problem of non-identifiability. Although identifiability analysis has been extensively studied by analytical as well as numerical approaches, systematic methods for remedying practically non-identifiable models have rarely been investigated. We propose a simple method for identifying pairwise correlations and higher order interrelationships of parameters in partially observed linear dynamic models. This is made by derivation of the output sensitivity matrix and analysis of the linear dependencies of its columns. Consequently, analytical relations between the identifiability of the model parameters and the initial conditions as well as the input functions can be achieved. In the case of structural non-identifiability, identifiable combinations can be obtained by solving the resulting homogenous linear equations. In the case of practical non-identifiability, experiment conditions (i.e. initial condition and constant control signals) can be provided which are necessary for remedying the non-identifiability and unique parameter estimation. It is noted that the approach does not consider noisy data. In this way, the practical non-identifiability issue, which is popular for linear biological models, can be remedied. Several linear compartment models including an insulin receptor dynamics model are taken to illustrate the application of the proposed approach. Both structural and practical identifiability of partially observed linear dynamic models can be clarified by the proposed method. The result of this method provides important information for experimental design to remedy the practical non-identifiability if applicable. The derivation of the method is straightforward and thus the algorithm can be easily implemented into a

  12. An Alternative Method of Intermaxillary Fixation for Simple Pediatric Mandible Fractures.

    Science.gov (United States)

    Farber, Scott J; Nguyen, Dennis C; Harvey, Alan A; Patel, Kamlesh B

    2016-03-01

    Mandibular fractures represent a substantial portion of facial fractures in the pediatric population. Pediatric mandibles differ from their adult counterparts in the presence of mixed dentition. Avoidance of injury to developing tooth follicles is critical. Simple mandibular fractures can be treated with intermaxillary fixation (IMF) using arch bars or bone screws. This report describes an alternative to these methods using silk sutures and an algorithm to assist in treating simple mandibular fractures in the pediatric population. A retrospective chart review was performed and the records of 1 surgeon were examined. Pediatric patients who underwent treatment for a mandibular fracture in the operating room from 2011 to 2015 were identified using Common Procedural Terminology codes. Data collected included age, gender, type of fracture, type of treatment used, duration of fixation, and presence of complications. Five patients with a mean age of 6.8 years at presentation were identified. Fracture types were unilateral fractures of the condylar neck (n = 3), bilateral fractures of the condylar head (n = 1), and a unilateral fracture of the condylar head with an associated parasymphyseal fracture (n = 1). IMF was performed in 4 patients using silk sutures, and bone screw fixation was performed in the other patient. No post-treatment complications or malocclusion were reported. Average duration of IMF was 18.5 days. An algorithm is presented to assist in the treatment of pediatric mandibular fractures. Silk suture fixation is a viable and safe alternative to arch bars or bone screws for routine mandibular fractures. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  13. S-MRI score: A simple method for assessing bone marrow involvement in Gaucher disease

    International Nuclear Information System (INIS)

    Roca, M.; Mota, J.; Alfonso, P.; Pocovi, M.; Giraldo, P.

    2007-01-01

    Semi quantitative MRI is a very useful procedure for evaluating the bone marrow burden (BMB) in Gaucher disease (GD). Score systems have been applied to obtain a parameter for evaluating the severity of bone disease. Our purpose was to test a simple, reproducible and accurate score to evaluate bone marrow involvement in GD patients. MRI was performed in spine, pelvis and femora at diagnosis in 54 adult GD1 patients, 61.1% of whom were female. Three MRI patterns and punctuation in each location were defined: normal, 0; non-homogeneous infiltration subtypes reticular, 1; mottled, 2; diffuse, 3; and homogeneous infiltration, 4. This score was called Spanish-MRI (S-MRI). Two independent observers applied the S-MRI and bone marrow burden score and compared the differences using the non-parametric Mann-Whitney test. Correlation rank test was calculated. In 46 patients (85.2%), bone involvement was observed. Thirty-nine (72.3%) had their spine affected, 35 (64.8%) pelvis and 33 (61.2%) femora. Fourteen patients had bone infarcts, 14 avascular necrosis, 2 vertebral fractures and 2 bone crises. Correlation analysis between S-MRI and BMB was (r 2 = .675; p = .0001). No evidence of correlation was observed between CT activity and S-MRI nor between CT activity and BMB. We have found a relationship between genotype and bone infiltration according to S-MRI site and complications. S-MRI is a simple method that provides useful information to evaluate bone infiltration and detect silent complications. Our results correlated with the BMB score but offer higher sensitivity, specificity and accuracy for classifying the extent of bone disease

  14. A Simple Method for Transportation of Mouse Embryos Using Microtubes and a Warm Box.

    Directory of Open Access Journals (Sweden)

    Mikiko Tokoro

    Full Text Available Generally, transportation of preimplantation embryos without freezing requires incubators that can maintain an optimal culture environment with a suitable gas phase, temperature, and humidity. Such incubators are expensive to transport. We reported previously that normal offspring were obtained when the gas phase and temperature could be maintained during transportation. However, that system used plastic dishes for embryo culture and is unsuitable for long-distance transport of live embryos. Here, we developed a simple low-cost embryo transportation system. Instead of plastic dishes, several types of microtubes-usually used for molecular analysis-were tested for embryo culture. When they were washed and attached to a gas-permeable film, the rate of embryo development from the 1-cell to blastocyst stage was more than 90%. The quality of these blastocysts and the rate of full-term development after embryo transfer to recipient female mice were similar to those of a dish-cultured control group. Next, we developed a small warm box powered by a battery instead of mains power, which could maintain an optimal temperature for embryo development during transport. When 1-cell embryos derived from BDF1, C57BL/6, C3H/He and ICR mouse strains were transported by a parcel-delivery service over 3 days using microtubes and the box, they developed to blastocysts with rates similar to controls. After the embryos had been transferred into recipient female mice, healthy offspring were obtained without any losses except for the C3H/He strain. Thus, transport of mouse embryos is possible using this very simple method, which might prove useful in the field of reproductive medicine.

  15. S-MRI score: A simple method for assessing bone marrow involvement in Gaucher disease

    Energy Technology Data Exchange (ETDEWEB)

    Roca, M. [Radiology (Magnetic Resonance) Instituto Aragones de Ciencias de la Salud (I-CS), Zaragoza (Spain); Mota, J. [Diagnostic Imaging Department, Medimagen, Barcelona (Spain); Alfonso, P. [Radiology (Magnetic Resonance) Instituto Aragones de Ciencias de la Salud (I-CS), Zaragoza (Spain); Pocovi, M. [Biochemistry and Cellular and Molecular Biology Department, Zaragoza University (Spain); Giraldo, P. [Haematology Department, Miguel Servet University Hospital, 50009 Zaragoza (Spain)]. E-mail: pgiraldo@salud.aragon.es

    2007-04-15

    Semi quantitative MRI is a very useful procedure for evaluating the bone marrow burden (BMB) in Gaucher disease (GD). Score systems have been applied to obtain a parameter for evaluating the severity of bone disease. Our purpose was to test a simple, reproducible and accurate score to evaluate bone marrow involvement in GD patients. MRI was performed in spine, pelvis and femora at diagnosis in 54 adult GD1 patients, 61.1% of whom were female. Three MRI patterns and punctuation in each location were defined: normal, 0; non-homogeneous infiltration subtypes reticular, 1; mottled, 2; diffuse, 3; and homogeneous infiltration, 4. This score was called Spanish-MRI (S-MRI). Two independent observers applied the S-MRI and bone marrow burden score and compared the differences using the non-parametric Mann-Whitney test. Correlation rank test was calculated. In 46 patients (85.2%), bone involvement was observed. Thirty-nine (72.3%) had their spine affected, 35 (64.8%) pelvis and 33 (61.2%) femora. Fourteen patients had bone infarcts, 14 avascular necrosis, 2 vertebral fractures and 2 bone crises. Correlation analysis between S-MRI and BMB was (r {sup 2} = .675; p = .0001). No evidence of correlation was observed between CT activity and S-MRI nor between CT activity and BMB. We have found a relationship between genotype and bone infiltration according to S-MRI site and complications. S-MRI is a simple method that provides useful information to evaluate bone infiltration and detect silent complications. Our results correlated with the BMB score but offer higher sensitivity, specificity and accuracy for classifying the extent of bone disease.

  16. A New, Simple Method for Estimating Pleural Effusion Size on CT Scans

    Science.gov (United States)

    Moy, Matthew P.; Berko, Netanel S.; Godelman, Alla; Jain, Vineet R.; Haramati, Linda B.

    2013-01-01

    Background: There is no standardized system to grade pleural effusion size on CT scans. A validated, systematic grading system would improve communication of findings and may help determine the need for imaging guidance for thoracentesis. Methods: CT scans of 34 patients demonstrating a wide range of pleural effusion sizes were measured with a volume segmentation tool and reviewed for qualitative and simple quantitative features related to size. A classification rule was developed using the features that best predicted size and distinguished among small, moderate, and large effusions. Inter-reader agreement for effusion size was assessed on the CT scans for three groups of physicians (radiology residents, pulmonologists, and cardiothoracic radiologists) before and after implementation of the classification rule. Results: The CT imaging features found to best classify effusions as small, moderate, or large were anteroposterior (AP) quartile and maximum AP depth measured at the midclavicular line. According to the decision rule, first AP-quartile effusions are small, second AP-quartile effusions are moderate, and third or fourth AP-quartile effusions are large. In borderline cases, AP depth is measured with 3-cm and 10-cm thresholds for the upper limit of small and moderate, respectively. Use of the rule improved interobserver agreement from κ = 0.56 to 0.79 for all physicians, 0.59 to 0.73 for radiology residents, 0.54 to 0.76 for pulmonologists, and 0.74 to 0.85 for cardiothoracic radiologists. Conclusions: A simple, two-step decision rule for sizing pleural effusions on CT scans improves interobserver agreement from moderate to substantial levels. PMID:23632863

  17. CUMBIN - CUMULATIVE BINOMIAL PROGRAMS

    Science.gov (United States)

    Bowerman, P. N.

    1994-01-01

    The cumulative binomial program, CUMBIN, is one of a set of three programs which calculate cumulative binomial probability distributions for arbitrary inputs. The three programs, CUMBIN, NEWTONP (NPO-17556), and CROSSER (NPO-17557), can be used independently of one another. CUMBIN can be used by statisticians and users of statistical procedures, test planners, designers, and numerical analysts. The program has been used for reliability/availability calculations. CUMBIN calculates the probability that a system of n components has at least k operating if the probability that any one operating is p and the components are independent. Equivalently, this is the reliability of a k-out-of-n system having independent components with common reliability p. CUMBIN can evaluate the incomplete beta distribution for two positive integer arguments. CUMBIN can also evaluate the cumulative F distribution and the negative binomial distribution, and can determine the sample size in a test design. CUMBIN is designed to work well with all integer values 0 < k <= n. To run the program, the user simply runs the executable version and inputs the information requested by the program. The program is not designed to weed out incorrect inputs, so the user must take care to make sure the inputs are correct. Once all input has been entered, the program calculates and lists the result. The CUMBIN program is written in C. It was developed on an IBM AT with a numeric co-processor using Microsoft C 5.0. Because the source code is written using standard C structures and functions, it should compile correctly with most C compilers. The program format is interactive. It has been implemented under DOS 3.2 and has a memory requirement of 26K. CUMBIN was developed in 1988.

  18. Standard test method for ranking resistance of plastics to sliding wear using block-on-ring wear test—cumulative wear method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This test method covers laboratory procedures for determining the resistance of plastics to sliding wear. The test utilizes a block-on-ring friction and wear testing machine to rank plastics according to their sliding wear characteristics against metals or other solids. 1.2 An important attribute of this test is that it is very flexible. Any material that can be fabricated into, or applied to, blocks and rings can be tested. Thus, the potential materials combinations are endless. In addition, the test can be run with different gaseous atmospheres and elevated temperatures, as desired, to simulate service conditions. 1.3 Wear test results are reported as the volume loss in cubic millimetres for the block and ring. Materials of higher wear resistance will have lower volume loss. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with it...

  19. Cumulation of light nuclei

    International Nuclear Information System (INIS)

    Baldin, A.M.; Bondarev, V.K.; Golovanov, L.B.

    1977-01-01

    Limit fragmentation of light nuclei (deuterium, helium) bombarded with 8,6 GeV/c protons was investigated. Fragments (pions, protons and deuterons) were detected within the emission angle 50-150 deg with regard to primary protons and within the pulse range 150-180 MeV/c. By the kinematics of collision of a primary proton with a target at rest the fragments observed correspond to a target mass upto 3 GeV. Thus, the data obtained correspond to teh cumulation upto the third order

  20. Measurement of long-range multiparticle azimuthal correlations with the subevent cumulant method in p p and p +Pb collisions with the ATLAS detector at the CERN Large Hadron Collider

    Science.gov (United States)

    Aaboud, M.; Aad, G.; Abbott, B.; Abdinov, O.; Abeloos, B.; Abidi, S. H.; Abouzeid, O. S.; Abraham, N. L.; Abramowicz, H.; Abreu, H.; Abreu, R.; Abulaiti, Y.; Acharya, B. S.; Adachi, S.; Adamczyk, L.; Adelman, J.; Adersberger, M.; Adye, T.; Affolder, A. A.; Afik, Y.; Agatonovic-Jovin, T.; Agheorghiesei, C.; Aguilar-Saavedra, J. A.; Ahlen, S. P.; Ahmadov, F.; Aielli, G.; Akatsuka, S.; Akerstedt, H.; Åkesson, T. P. A.; Akilli, E.; Akimov, A. V.; Alberghi, G. L.; Albert, J.; Albicocco, P.; Alconada Verzini, M. J.; Alderweireldt, S. C.; Aleksa, M.; Aleksandrov, I. N.; Alexa, C.; Alexander, G.; Alexopoulos, T.; Alhroob, M.; Ali, B.; Aliev, M.; Alimonti, G.; Alison, J.; Alkire, S. P.; Allbrooke, B. M. M.; Allen, B. W.; Allport, P. P.; Aloisio, A.; Alonso, A.; Alonso, F.; Alpigiani, C.; Alshehri, A. A.; Alstaty, M. I.; Alvarez Gonzalez, B.; Álvarez Piqueras, D.; Alviggi, M. G.; Amadio, B. T.; Amaral Coutinho, Y.; Amelung, C.; Amidei, D.; Amor Dos Santos, S. P.; Amoroso, S.; Amundsen, G.; Anastopoulos, C.; Ancu, L. S.; Andari, N.; Andeen, T.; Anders, C. F.; Anders, J. K.; Anderson, K. J.; Andreazza, A.; Andrei, V.; Angelidakis, S.; Angelozzi, I.; Angerami, A.; Anisenkov, A. V.; Anjos, N.; Annovi, A.; Antel, C.; Antonelli, M.; Antonov, A.; Antrim, D. J.; Anulli, F.; Aoki, M.; Aperio Bella, L.; Arabidze, G.; Arai, Y.; Araque, J. P.; Araujo Ferraz, V.; Arce, A. T. H.; Ardell, R. E.; Arduh, F. A.; Arguin, J.-F.; Argyropoulos, S.; Arik, M.; Armbruster, A. J.; Armitage, L. J.; Arnaez, O.; Arnold, H.; Arratia, M.; Arslan, O.; Artamonov, A.; Artoni, G.; Artz, S.; Asai, S.; Asbah, N.; Ashkenazi, A.; Asquith, L.; Assamagan, K.; Astalos, R.; Atkinson, M.; Atlay, N. B.; Augsten, K.; Avolio, G.; Axen, B.; Ayoub, M. K.; Azuelos, G.; Baas, A. E.; Baca, M. J.; Bachacou, H.; Bachas, K.; Backes, M.; Bagnaia, P.; Bahmani, M.; Bahrasemani, H.; Baines, J. T.; Bajic, M.; Baker, O. K.; Bakker, P. J.; Baldin, E. M.; Balek, P.; Balli, F.; Balunas, W. K.; Banas, E.; Bandyopadhyay, A.; Banerjee, Sw.; Bannoura, A. A. E.; Barak, L.; Barberio, E. L.; Barberis, D.; Barbero, M.; Barillari, T.; Barisits, M.-S.; Barkeloo, J. T.; Barklow, T.; Barlow, N.; Barnes, S. L.; Barnett, B. M.; Barnett, R. M.; Barnovska-Blenessy, Z.; Baroncelli, A.; Barone, G.; Barr, A. J.; Barranco Navarro, L.; Barreiro, F.; Barreiro Guimarães da Costa, J.; Bartoldus, R.; Barton, A. E.; Bartos, P.; Basalaev, A.; Bassalat, A.; Bates, R. L.; Batista, S. J.; Batley, J. R.; Battaglia, M.; Bauce, M.; Bauer, F.; Bawa, H. S.; Beacham, J. B.; Beattie, M. D.; Beau, T.; Beauchemin, P. H.; Bechtle, P.; Beck, H. P.; Beck, H. C.; Becker, K.; Becker, M.; Becot, C.; Beddall, A. J.; Beddall, A.; Bednyakov, V. A.; Bedognetti, M.; Bee, C. P.; Beermann, T. A.; Begalli, M.; Begel, M.; Behr, J. K.; Bell, A. S.; Bella, G.; Bellagamba, L.; Bellerive, A.; Bellomo, M.; Belotskiy, K.; Beltramello, O.; Belyaev, N. L.; Benary, O.; Benchekroun, D.; Bender, M.; Benekos, N.; Benhammou, Y.; Benhar Noccioli, E.; Benitez, J.; Benjamin, D. P.; Benoit, M.; Bensinger, J. R.; Bentvelsen, S.; Beresford, L.; Beretta, M.; Berge, D.; Bergeaas Kuutmann, E.; Berger, N.; Beringer, J.; Berlendis, S.; Bernard, N. R.; Bernardi, G.; Bernius, C.; Bernlochner, F. U.; Berry, T.; Berta, P.; Bertella, C.; Bertoli, G.; Bertram, I. A.; Bertsche, C.; Bertsche, D.; Besjes, G. J.; Bessidskaia Bylund, O.; Bessner, M.; Besson, N.; Bethani, A.; Bethke, S.; Betti, A.; Bevan, A. J.; Beyer, J.; Bianchi, R. M.; Biebel, O.; Biedermann, D.; Bielski, R.; Bierwagen, K.; Biesuz, N. V.; Biglietti, M.; Billoud, T. R. V.; Bilokon, H.; Bindi, M.; Bingul, A.; Bini, C.; Biondi, S.; Bisanz, T.; Bittrich, C.; Bjergaard, D. M.; Black, J. E.; Black, K. M.; Blair, R. E.; Blazek, T.; Bloch, I.; Blocker, C.; Blue, A.; Blumenschein, U.; Blunier, S.; Bobbink, G. J.; Bobrovnikov, V. S.; Bocchetta, S. S.; Bocci, A.; Bock, C.; Boehler, M.; Boerner, D.; Bogavac, D.; Bogdanchikov, A. G.; Bohm, C.; Boisvert, V.; Bokan, P.; Bold, T.; Boldyrev, A. S.; Bolz, A. E.; Bomben, M.; Bona, M.; Boonekamp, M.; Borisov, A.; Borissov, G.; Bortfeldt, J.; Bortoletto, D.; Bortolotto, V.; Boscherini, D.; Bosman, M.; Bossio Sola, J. D.; Boudreau, J.; Bouhova-Thacker, E. V.; Boumediene, D.; Bourdarios, C.; Boutle, S. K.; Boveia, A.; Boyd, J.; Boyko, I. R.; Bozson, A. J.; Bracinik, J.; Brandt, A.; Brandt, G.; Brandt, O.; Braren, F.; Bratzler, U.; Brau, B.; Brau, J. E.; Breaden Madden, W. D.; Brendlinger, K.; Brennan, A. J.; Brenner, L.; Brenner, R.; Bressler, S.; Briglin, D. L.; Bristow, T. M.; Britton, D.; Britzger, D.; Brochu, F. M.; Brock, I.; Brock, R.; Brooijmans, G.; Brooks, T.; Brooks, W. K.; Brosamer, J.; Brost, E.; Broughton, J. H.; Bruckman de Renstrom, P. A.; Bruncko, D.; Bruni, A.; Bruni, G.; Bruni, L. S.; Bruno, S.; Brunt, B. H.; Bruschi, M.; Bruscino, N.; Bryant, P.; Bryngemark, L.; Buanes, T.; Buat, Q.; Buchholz, P.; Buckley, A. G.; Budagov, I. A.; Buehrer, F.; Bugge, M. K.; Bulekov, O.; Bullock, D.; Burch, T. J.; Burdin, S.; Burgard, C. D.; Burger, A. M.; Burghgrave, B.; Burka, K.; Burke, S.; Burmeister, I.; Burr, J. T. P.; Büscher, D.; Büscher, V.; Bussey, P.; Butler, J. M.; Buttar, C. M.; Butterworth, J. M.; Butti, P.; Buttinger, W.; Buzatu, A.; Buzykaev, A. R.; Cabrera Urbán, S.; Caforio, D.; Cai, H.; Cairo, V. M.; Cakir, O.; Calace, N.; Calafiura, P.; Calandri, A.; Calderini, G.; Calfayan, P.; Callea, G.; Caloba, L. P.; Calvente Lopez, S.; Calvet, D.; Calvet, S.; Calvet, T. P.; Camacho Toro, R.; Camarda, S.; Camarri, P.; Cameron, D.; Caminal Armadans, R.; Camincher, C.; Campana, S.; Campanelli, M.; Camplani, A.; Campoverde, A.; Canale, V.; Cano Bret, M.; Cantero, J.; Cao, T.; Capeans Garrido, M. D. M.; Caprini, I.; Caprini, M.; Capua, M.; Carbone, R. M.; Cardarelli, R.; Cardillo, F.; Carli, I.; Carli, T.; Carlino, G.; Carlson, B. T.; Carminati, L.; Carney, R. M. D.; Caron, S.; Carquin, E.; Carrá, S.; Carrillo-Montoya, G. D.; Casadei, D.; Casado, M. P.; Casolino, M.; Casper, D. W.; Castelijn, R.; Castillo Gimenez, V.; Castro, N. F.; Catinaccio, A.; Catmore, J. R.; Cattai, A.; Caudron, J.; Cavaliere, V.; Cavallaro, E.; Cavalli, D.; Cavalli-Sforza, M.; Cavasinni, V.; Celebi, E.; Ceradini, F.; Cerda Alberich, L.; Cerqueira, A. S.; Cerri, A.; Cerrito, L.; Cerutti, F.; Cervelli, A.; Cetin, S. A.; Chafaq, A.; Chakraborty, D.; Chan, S. K.; Chan, W. S.; Chan, Y. L.; Chang, P.; Chapman, J. D.; Charlton, D. G.; Chau, C. C.; Chavez Barajas, C. A.; Che, S.; Cheatham, S.; Chegwidden, A.; Chekanov, S.; Chekulaev, S. V.; Chelkov, G. A.; Chelstowska, M. A.; Chen, C.; Chen, C.; Chen, H.; Chen, J.; Chen, S.; Chen, S.; Chen, X.; Chen, Y.; Cheng, H. C.; Cheng, H. J.; Cheplakov, A.; Cheremushkina, E.; Cherkaoui El Moursli, R.; Cheu, E.; Cheung, K.; Chevalier, L.; Chiarella, V.; Chiarelli, G.; Chiodini, G.; Chisholm, A. S.; Chitan, A.; Chiu, Y. H.; Chizhov, M. V.; Choi, K.; Chomont, A. R.; Chouridou, S.; Chow, Y. S.; Christodoulou, V.; Chu, M. C.; Chudoba, J.; Chuinard, A. J.; Chwastowski, J. J.; Chytka, L.; Ciftci, A. K.; Cinca, D.; Cindro, V.; Cioara, I. A.; Ciocio, A.; Cirotto, F.; Citron, Z. H.; Citterio, M.; Ciubancan, M.; Clark, A.; Clark, B. L.; Clark, M. R.; Clark, P. J.; Clarke, R. N.; Clement, C.; Coadou, Y.; Cobal, M.; Coccaro, A.; Cochran, J.; Colasurdo, L.; Cole, B.; Colijn, A. P.; Collot, J.; Colombo, T.; Conde Muiño, P.; Coniavitis, E.; Connell, S. H.; Connelly, I. A.; Constantinescu, S.; Conti, G.; Conventi, F.; Cooke, M.; Cooper-Sarkar, A. M.; Cormier, F.; Cormier, K. J. R.; Corradi, M.; Corriveau, F.; Cortes-Gonzalez, A.; Costa, G.; Costa, M. J.; Costanzo, D.; Cottin, G.; Cowan, G.; Cox, B. E.; Cranmer, K.; Crawley, S. J.; Creager, R. A.; Cree, G.; Crépé-Renaudin, S.; Crescioli, F.; Cribbs, W. A.; Cristinziani, M.; Croft, V.; Crosetti, G.; Cueto, A.; Cuhadar Donszelmann, T.; Cukierman, A. R.; Cummings, J.; Curatolo, M.; Cúth, J.; Czekierda, S.; Czodrowski, P.; D'Amen, G.; D'Auria, S.; D'Eramo, L.; D'Onofrio, M.; da Cunha Sargedas de Sousa, M. J.; da Via, C.; Dabrowski, W.; Dado, T.; Dai, T.; Dale, O.; Dallaire, F.; Dallapiccola, C.; Dam, M.; Dandoy, J. R.; Daneri, M. F.; Dang, N. P.; Daniells, A. C.; Dann, N. S.; Danninger, M.; Dano Hoffmann, M.; Dao, V.; Darbo, G.; Darmora, S.; Dassoulas, J.; Dattagupta, A.; Daubney, T.; Davey, W.; David, C.; Davidek, T.; Davis, D. R.; Davison, P.; Dawe, E.; Dawson, I.; de, K.; de Asmundis, R.; de Benedetti, A.; de Castro, S.; de Cecco, S.; de Groot, N.; de Jong, P.; de la Torre, H.; de Lorenzi, F.; de Maria, A.; de Pedis, D.; de Salvo, A.; de Sanctis, U.; de Santo, A.; de Vasconcelos Corga, K.; de Vivie de Regie, J. B.; Debbe, R.; Debenedetti, C.; Dedovich, D. V.; Dehghanian, N.; Deigaard, I.; Del Gaudio, M.; Del Peso, J.; Delgove, D.; Deliot, F.; Delitzsch, C. M.; Dell'Acqua, A.; Dell'Asta, L.; Dell'Orso, M.; Della Pietra, M.; Della Volpe, D.; Delmastro, M.; Delporte, C.; Delsart, P. A.; Demarco, D. A.; Demers, S.; Demichev, M.; Demilly, A.; Denisov, S. P.; Denysiuk, D.; Derendarz, D.; Derkaoui, J. E.; Derue, F.; Dervan, P.; Desch, K.; Deterre, C.; Dette, K.; Devesa, M. R.; Deviveiros, P. O.; Dewhurst, A.; Dhaliwal, S.; di Bello, F. A.; di Ciaccio, A.; di Ciaccio, L.; di Clemente, W. K.; di Donato, C.; di Girolamo, A.; di Girolamo, B.; di Micco, B.; di Nardo, R.; di Petrillo, K. F.; di Simone, A.; di Sipio, R.; di Valentino, D.; Diaconu, C.; Diamond, M.; Dias, F. A.; Diaz, M. A.; Diehl, E. B.; Dietrich, J.; Díez Cornell, S.; Dimitrievska, A.; Dingfelder, J.; Dita, P.; Dita, S.; Dittus, F.; Djama, F.; Djobava, T.; Djuvsland, J. I.; Do Vale, M. A. B.; Dobos, D.; Dobre, M.; Dodsworth, D.; Doglioni, C.; Dolejsi, J.; Dolezal, Z.; Donadelli, M.; Donati, S.; Dondero, P.; Donini, J.; Dopke, J.; Doria, A.; Dova, M. T.; Doyle, A. T.; Drechsler, E.; Dris, M.; Du, Y.; Duarte-Campderros, J.; Dubinin, F.; Dubreuil, A.; Duchovni, E.; Duckeck, G.; Ducourthial, A.; Ducu, O. A.; Duda, D.; Dudarev, A.; Dudder, A. Chr.; Duffield, E. M.; Duflot, L.; Dührssen, M.; Dulsen, C.; Dumancic, M.; Dumitriu, A. E.; Duncan, A. K.; Dunford, M.; Duperrin, A.; Duran Yildiz, H.; Düren, M.; Durglishvili, A.; Duschinger, D.; Dutta, B.; Duvnjak, D.; Dyndal, M.; Dziedzic, B. S.; Eckardt, C.; Ecker, K. M.; Edgar, R. C.; Eifert, T.; Eigen, G.; Einsweiler, K.; Ekelof, T.; El Kacimi, M.; El Kosseifi, R.; Ellajosyula, V.; Ellert, M.; Elles, S.; Ellinghaus, F.; Elliot, A. A.; Ellis, N.; Elmsheuser, J.; Elsing, M.; Emeliyanov, D.; Enari, Y.; Ennis, J. S.; Epland, M. B.; Erdmann, J.; Ereditato, A.; Ernst, M.; Errede, S.; Escalier, M.; Escobar, C.; Esposito, B.; Estrada Pastor, O.; Etienvre, A. I.; Etzion, E.; Evans, H.; Ezhilov, A.; Ezzi, M.; Fabbri, F.; Fabbri, L.; Fabiani, V.; Facini, G.; Fakhrutdinov, R. M.; Falciano, S.; Falla, R. J.; Faltova, J.; Fang, Y.; Fanti, M.; Farbin, A.; Farilla, A.; Farina, C.; Farina, E. M.; Farooque, T.; Farrell, S.; Farrington, S. M.; Farthouat, P.; Fassi, F.; Fassnacht, P.; Fassouliotis, D.; Faucci Giannelli, M.; Favareto, A.; Fawcett, W. J.; Fayard, L.; Fedin, O. L.; Fedorko, W.; Feigl, S.; Feligioni, L.; Feng, C.; Feng, E. J.; Fenton, M. J.; Fenyuk, A. B.; Feremenga, L.; Fernandez Martinez, P.; Ferrando, J.; Ferrari, A.; Ferrari, P.; Ferrari, R.; Ferreira de Lima, D. E.; Ferrer, A.; Ferrere, D.; Ferretti, C.; Fiedler, F.; Filipčič, A.; Filipuzzi, M.; Filthaut, F.; Fincke-Keeler, M.; Finelli, K. D.; Fiolhais, M. C. N.; Fiorini, L.; Fischer, A.; Fischer, C.; Fischer, J.; Fisher, W. C.; Flaschel, N.; Fleck, I.; Fleischmann, P.; Fletcher, R. R. M.; Flick, T.; Flierl, B. M.; Flores Castillo, L. R.; Flowerdew, M. J.; Forcolin, G. T.; Formica, A.; Förster, F. A.; Forti, A.; Foster, A. G.; Fournier, D.; Fox, H.; Fracchia, S.; Francavilla, P.; Franchini, M.; Franchino, S.; Francis, D.; Franconi, L.; Franklin, M.; Frate, M.; Fraternali, M.; Freeborn, D.; Fressard-Batraneanu, S. M.; Freund, B.; Froidevaux, D.; Frost, J. A.; Fukunaga, C.; Fusayasu, T.; Fuster, J.; Gabizon, O.; Gabrielli, A.; Gabrielli, A.; Gach, G. P.; Gadatsch, S.; Gadomski, S.; Gagliardi, G.; Gagnon, L. G.; Galea, C.; Galhardo, B.; Gallas, E. J.; Gallop, B. J.; Gallus, P.; Galster, G.; Gan, K. K.; Ganguly, S.; Gao, Y.; Gao, Y. S.; Garay Walls, F. M.; García, C.; García Navarro, J. E.; García Pascual, J. A.; Garcia-Sciveres, M.; Gardner, R. W.; Garelli, N.; Garonne, V.; Gascon Bravo, A.; Gasnikova, K.; Gatti, C.; Gaudiello, A.; Gaudio, G.; Gavrilenko, I. L.; Gay, C.; Gaycken, G.; Gazis, E. N.; Gee, C. N. P.; Geisen, J.; Geisen, M.; Geisler, M. P.; Gellerstedt, K.; Gemme, C.; Genest, M. H.; Geng, C.; Gentile, S.; Gentsos, C.; George, S.; Gerbaudo, D.; Geßner, G.; Ghasemi, S.; Ghneimat, M.; Giacobbe, B.; Giagu, S.; Giangiacomi, N.; Giannetti, P.; Gibson, S. M.; Gignac, M.; Gilchriese, M.; Gillberg, D.; Gilles, G.; Gingrich, D. M.; Giordani, M. P.; Giorgi, F. M.; Giraud, P. F.; Giromini, P.; Giugliarelli, G.; Giugni, D.; Giuli, F.; Giuliani, C.; Giulini, M.; Gjelsten, B. K.; Gkaitatzis, S.; Gkialas, I.; Gkougkousis, E. L.; Gkountoumis, P.; Gladilin, L. K.; Glasman, C.; Glatzer, J.; Glaysher, P. C. F.; Glazov, A.; Goblirsch-Kolb, M.; Godlewski, J.; Goldfarb, S.; Golling, T.; Golubkov, D.; Gomes, A.; Gonçalo, R.; Goncalves Gama, R.; Goncalves Pinto Firmino da Costa, J.; Gonella, G.; Gonella, L.; Gongadze, A.; Gonski, J. L.; González de La Hoz, S.; Gonzalez-Sevilla, S.; Goossens, L.; Gorbounov, P. A.; Gordon, H. A.; Gorelov, I.; Gorini, B.; Gorini, E.; Gorišek, A.; Goshaw, A. T.; Gössling, C.; Gostkin, M. I.; Gottardo, C. A.; Goudet, C. R.; Goujdami, D.; Goussiou, A. G.; Govender, N.; Gozani, E.; Grabowska-Bold, I.; Gradin, P. O. J.; Gramling, J.; Gramstad, E.; Grancagnolo, S.; Gratchev, V.; Gravila, P. M.; Gray, C.; Gray, H. M.; Greenwood, Z. D.; Grefe, C.; Gregersen, K.; Gregor, I. M.; Grenier, P.; Grevtsov, K.; Griffiths, J.; Grillo, A. A.; Grimm, K.; Grinstein, S.; Gris, Ph.; Grivaz, J.-F.; Groh, S.; Gross, E.; Grosse-Knetter, J.; Grossi, G. C.; Grout, Z. J.; Grummer, A.; Guan, L.; Guan, W.; Guenther, J.; Guescini, F.; Guest, D.; Gueta, O.; Gui, B.; Guido, E.; Guillemin, T.; Guindon, S.; Gul, U.; Gumpert, C.; Guo, J.; Guo, W.; Guo, Y.; Gupta, R.; Gurbuz, S.; Gustavino, G.; Gutelman, B. J.; Gutierrez, P.; Gutierrez Ortiz, N. G.; Gutschow, C.; Guyot, C.; Guzik, M. P.; Gwenlan, C.; Gwilliam, C. B.; Haas, A.; Haber, C.; Hadavand, H. K.; Haddad, N.; Hadef, A.; Hageböck, S.; Hagihara, M.; Hakobyan, H.; Haleem, M.; Haley, J.; Halladjian, G.; Hallewell, G. D.; Hamacher, K.; Hamal, P.; Hamano, K.; Hamilton, A.; Hamity, G. N.; Hamnett, P. G.; Han, L.; Han, S.; Hanagaki, K.; Hanawa, K.; Hance, M.; Handl, D. M.; Haney, B.; Hanke, P.; Hansen, J. B.; Hansen, J. D.; Hansen, M. C.; Hansen, P. H.; Hara, K.; Hard, A. S.; Harenberg, T.; Hariri, F.; Harkusha, S.; Harrison, P. F.; Hartmann, N. M.; Hasegawa, Y.; Hasib, A.; Hassani, S.; Haug, S.; Hauser, R.; Hauswald, L.; Havener, L. B.; Havranek, M.; Hawkes, C. M.; Hawkings, R. J.; Hayakawa, D.; Hayden, D.; Hays, C. P.; Hays, J. M.; Hayward, H. S.; Haywood, S. J.; Head, S. J.; Heck, T.; Hedberg, V.; Heelan, L.; Heer, S.; Heidegger, K. K.; Heim, S.; Heim, T.; Heinemann, B.; Heinrich, J. J.; Heinrich, L.; Heinz, C.; Hejbal, J.; Helary, L.; Held, A.; Hellman, S.; Helsens, C.; Henderson, R. C. W.; Heng, Y.; Henkelmann, S.; Henriques Correia, A. M.; Henrot-Versille, S.; Herbert, G. H.; Herde, H.; Herget, V.; Hernández Jiménez, Y.; Herr, H.; Herten, G.; Hertenberger, R.; Hervas, L.; Herwig, T. C.; Hesketh, G. G.; Hessey, N. P.; Hetherly, J. W.; Higashino, S.; Higón-Rodriguez, E.; Hildebrand, K.; Hill, E.; Hill, J. C.; Hiller, K. H.; Hillier, S. J.; Hils, M.; Hinchliffe, I.; Hirose, M.; Hirschbuehl, D.; Hiti, B.; Hladik, O.; Hlaluku, D. R.; Hoad, X.; Hobbs, J.; Hod, N.; Hodgkinson, M. C.; Hodgson, P.; Hoecker, A.; Hoeferkamp, M. R.; Hoenig, F.; Hohn, D.; Holmes, T. R.; Homann, M.; Honda, S.; Honda, T.; Hong, T. M.; Hooberman, B. H.; Hopkins, W. H.; Horii, Y.; Horton, A. J.; Hostachy, J.-Y.; Hostiuc, A.; Hou, S.; Hoummada, A.; Howarth, J.; Hoya, J.; Hrabovsky, M.; Hrdinka, J.; Hristova, I.; Hrivnac, J.; Hryn'ova, T.; Hrynevich, A.; Hsu, P. J.; Hsu, S.-C.; Hu, Q.; Hu, S.; Huang, Y.; Hubacek, Z.; Hubaut, F.; Huegging, F.; Huffman, T. B.; Hughes, E. W.; Huhtinen, M.; Hunter, R. F. H.; Huo, P.; Huseynov, N.; Huston, J.; Huth, J.; Hyneman, R.; Iacobucci, G.; Iakovidis, G.; Ibragimov, I.; Iconomidou-Fayard, L.; Idrissi, Z.; Iengo, P.; Igonkina, O.; Iizawa, T.; Ikegami, Y.; Ikeno, M.; Ilchenko, Y.; Iliadis, D.; Ilic, N.; Iltzsche, F.; Introzzi, G.; Ioannou, P.; Iodice, M.; Iordanidou, K.; Ippolito, V.; Isacson, M. F.; Ishijima, N.; Ishino, M.; Ishitsuka, M.; Issever, C.; Istin, S.; Ito, F.; Iturbe Ponce, J. M.; Iuppa, R.; Iwasaki, H.; Izen, J. M.; Izzo, V.; Jabbar, S.; Jackson, P.; Jacobs, R. M.; Jain, V.; Jakobi, K. B.; Jakobs, K.; Jakobsen, S.; Jakoubek, T.; Jamin, D. O.; Jana, D. K.; Jansky, R.; Janssen, J.; Janus, M.; Janus, P. A.; Jarlskog, G.; Javadov, N.; Javå¯Rek, T.; Javurkova, M.; Jeanneau, F.; Jeanty, L.; Jejelava, J.; Jelinskas, A.; Jenni, P.; Jeske, C.; Jézéquel, S.; Ji, H.; Jia, J.; Jiang, H.; Jiang, Y.; Jiang, Z.; Jiggins, S.; Jimenez Pena, J.; Jin, S.; Jinaru, A.; Jinnouchi, O.; Jivan, H.; Johansson, P.; Johns, K. A.; Johnson, C. A.; Johnson, W. J.; Jon-And, K.; Jones, R. W. L.; Jones, S. D.; Jones, S.; Jones, T. J.; Jongmanns, J.; Jorge, P. M.; Jovicevic, J.; Ju, X.; Juste Rozas, A.; Köhler, M. K.; Kaczmarska, A.; Kado, M.; Kagan, H.; Kagan, M.; Kahn, S. J.; Kaji, T.; Kajomovitz, E.; Kalderon, C. W.; Kaluza, A.; Kama, S.; Kamenshchikov, A.; Kanaya, N.; Kanjir, L.; Kantserov, V. A.; Kanzaki, J.; Kaplan, B.; Kaplan, L. S.; Kar, D.; Karakostas, K.; Karastathis, N.; Kareem, M. J.; Karentzos, E.; Karpov, S. N.; Karpova, Z. M.; Karthik, K.; Kartvelishvili, V.; Karyukhin, A. N.; Kasahara, K.; Kashif, L.; Kass, R. D.; Kastanas, A.; Kataoka, Y.; Kato, C.; Katre, A.; Katzy, J.; Kawade, K.; Kawagoe, K.; Kawamoto, T.; Kawamura, G.; Kay, E. F.; Kazanin, V. F.; Keeler, R.; Kehoe, R.; Keller, J. S.; Kellermann, E.; Kempster, J. J.; Kendrick, J.; Keoshkerian, H.; Kepka, O.; Kerševan, B. P.; Kersten, S.; Keyes, R. A.; Khader, M.; Khalil-Zada, F.; Khanov, A.; Kharlamov, A. G.; Kharlamova, T.; Khodinov, A.; Khoo, T. J.; Khovanskiy, V.; Khramov, E.; Khubua, J.; Kido, S.; Kilby, C. R.; Kim, H. Y.; Kim, S. H.; Kim, Y. K.; Kimura, N.; Kind, O. M.; King, B. T.; Kirchmeier, D.; Kirk, J.; Kiryunin, A. E.; Kishimoto, T.; Kisielewska, D.; Kitali, V.; Kivernyk, O.; Kladiva, E.; Klapdor-Kleingrothaus, T.; Klein, M. H.; Klein, M.; Klein, U.; Kleinknecht, K.; Klimek, P.; Klimentov, A.; Klingenberg, R.; Klingl, T.; Klioutchnikova, T.; Klitzner, F. F.; Kluge, E.-E.; Kluit, P.; Kluth, S.; Kneringer, E.; Knoops, E. B. F. G.; Knue, A.; Kobayashi, A.; Kobayashi, D.; Kobayashi, T.; Kobel, M.; Kocian, M.; Kodys, P.; Koffas, T.; Koffeman, E.; Köhler, N. M.; Koi, T.; Kolb, M.; Koletsou, I.; Komar, A. A.; Kondo, T.; Kondrashova, N.; Köneke, K.; König, A. C.; Kono, T.; Konoplich, R.; Konstantinidis, N.; Konya, B.; Kopeliansky, R.; Koperny, S.; Kopp, A. K.; Korcyl, K.; Kordas, K.; Korn, A.; Korol, A. A.; Korolkov, I.; Korolkova, E. V.; Kortner, O.; Kortner, S.; Kosek, T.; Kostyukhin, V. V.; Kotwal, A.; Koulouris, A.; Kourkoumeli-Charalampidi, A.; Kourkoumelis, C.; Kourlitis, E.; Kouskoura, V.; Kowalewska, A. B.; Kowalewski, R.; Kowalski, T. Z.; Kozakai, C.; Kozanecki, W.; Kozhin, A. S.; Kramarenko, V. A.; Kramberger, G.; Krasnopevtsev, D.; Krasny, M. W.; Krasznahorkay, A.; Krauss, D.; Kremer, J. A.; Kretzschmar, J.; Kreutzfeldt, K.; Krieger, P.; Krizka, K.; Kroeninger, K.; Kroha, H.; Kroll, J.; Kroll, J.; Kroseberg, J.; Krstic, J.; Kruchonak, U.; Krüger, H.; Krumnack, N.; Kruse, M. C.; Kubota, T.; Kucuk, H.; Kuday, S.; Kuechler, J. T.; Kuehn, S.; Kugel, A.; Kuger, F.; Kuhl, T.; Kukhtin, V.; Kukla, R.; Kulchitsky, Y.; Kuleshov, S.; Kulinich, Y. P.; Kuna, M.; Kunigo, T.; Kupco, A.; Kupfer, T.; Kuprash, O.; Kurashige, H.; Kurchaninov, L. L.; Kurochkin, Y. A.; Kurth, M. G.; Kuwertz, E. S.; Kuze, M.; Kvita, J.; Kwan, T.; Kyriazopoulos, D.; La Rosa, A.; La Rosa Navarro, J. L.; La Rotonda, L.; La Ruffa, F.; Lacasta, C.; Lacava, F.; Lacey, J.; Lack, D. P. J.; Lacker, H.; Lacour, D.; Ladygin, E.; Lafaye, R.; Laforge, B.; Lagouri, T.; Lai, S.; Lammers, S.; Lampl, W.; Lançon, E.; Landgraf, U.; Landon, M. P. J.; Lanfermann, M. C.; Lang, V. S.; Lange, J. C.; Langenberg, R. J.; Lankford, A. J.; Lanni, F.; Lantzsch, K.; Lanza, A.; Lapertosa, A.; Laplace, S.; Laporte, J. F.; Lari, T.; Lasagni Manghi, F.; Lassnig, M.; Lau, T. S.; Laurelli, P.; Lavrijsen, W.; Law, A. T.; Laycock, P.; Lazovich, T.; Lazzaroni, M.; Le, B.; Le Dortz, O.; Le Guirriec, E.; Le Quilleuc, E. P.; Leblanc, M.; Lecompte, T.; Ledroit-Guillon, F.; Lee, C. A.; Lee, G. R.; Lee, S. C.; Lee, L.; Lefebvre, B.; Lefebvre, G.; Lefebvre, M.; Legger, F.; Leggett, C.; Lehmann Miotto, G.; Lei, X.; Leight, W. A.; Leite, M. A. L.; Leitner, R.; Lellouch, D.; Lemmer, B.; Leney, K. J. C.; Lenz, T.; Lenzi, B.; Leone, R.; Leone, S.; Leonidopoulos, C.; Lerner, G.; Leroy, C.; Les, R.; Lesage, A. A. J.; Lester, C. G.; Levchenko, M.; Levêque, J.; Levin, D.; Levinson, L. J.; Levy, M.; Lewis, D.; Li, B.; Li, Changqiao; Li, H.; Li, L.; Li, Q.; Li, Q.; Li, S.; Li, X.; Li, Y.; Liang, Z.; Liberti, B.; Liblong, A.; Lie, K.; Liebal, J.; Liebig, W.; Limosani, A.; Lin, K.; Lin, S. C.; Lin, T. H.; Linck, R. A.; Lindquist, B. E.; Lionti, A. E.; Lipeles, E.; Lipniacka, A.; Lisovyi, M.; Liss, T. M.; Lister, A.; Litke, A. M.; Liu, B.; Liu, H.; Liu, H.; Liu, J. K. K.; Liu, J.; Liu, J. B.; Liu, K.; Liu, L.; Liu, M.; Liu, Y. L.; Liu, Y.; Livan, M.; Lleres, A.; Llorente Merino, J.; Lloyd, S. L.; Lo, C. Y.; Lo Sterzo, F.; Lobodzinska, E. M.; Loch, P.; Loebinger, F. K.; Loesle, A.; Loew, K. M.; Lohse, T.; Lohwasser, K.; Lokajicek, M.; Long, B. A.; Long, J. D.; Long, R. E.; Longo, L.; Looper, K. A.; Lopez, J. A.; Lopez Paz, I.; Lopez Solis, A.; Lorenz, J.; Lorenzo Martinez, N.; Losada, M.; Lösel, P. J.; Lou, X.; Lounis, A.; Love, J.; Love, P. A.; Lu, H.; Lu, N.; Lu, Y. J.; Lubatti, H. J.; Luci, C.; Lucotte, A.; Luedtke, C.; Luehring, F.; Lukas, W.; Luminari, L.; Lundberg, O.; Lund-Jensen, B.; Lutz, M. S.; Luzi, P. M.; Lynn, D.; Lysak, R.; Lytken, E.; Lyu, F.; Lyubushkin, V.; Ma, H.; Ma, L. L.; Ma, Y.; Maccarrone, G.; Macchiolo, A.; MacDonald, C. M.; Maček, B.; Machado Miguens, J.; Madaffari, D.; Madar, R.; Mader, W. F.; Madsen, A.; Madysa, N.; Maeda, J.; Maeland, S.; Maeno, T.; Maevskiy, A. S.; Magerl, V.; Maiani, C.; Maidantchik, C.; Maier, T.; Maio, A.; Majersky, O.; Majewski, S.; Makida, Y.; Makovec, N.; Malaescu, B.; Malecki, Pa.; Maleev, V. P.; Malek, F.; Mallik, U.; Malon, D.; Malone, C.; Maltezos, S.; Malyukov, S.; Mamuzic, J.; Mancini, G.; Mandić, I.; Maneira, J.; Manhaes de Andrade Filho, L.; Manjarres Ramos, J.; Mankinen, K. H.; Mann, A.; Manousos, A.; Mansoulie, B.; Mansour, J. D.; Mantifel, R.; Mantoani, M.; Manzoni, S.; Mapelli, L.; Marceca, G.; March, L.; Marchese, L.; Marchiori, G.; Marcisovsky, M.; Marin Tobon, C. A.; Marjanovic, M.; Marley, D. E.; Marroquim, F.; Marsden, S. P.; Marshall, Z.; Martensson, M. U. F.; Marti-Garcia, S.; Martin, C. B.; Martin, T. A.; Martin, V. J.; Martin Dit Latour, B.; Martinez, M.; Martinez Outschoorn, V. I.; Martin-Haugh, S.; Martoiu, V. S.; Martyniuk, A. C.; Marzin, A.; Masetti, L.; Mashimo, T.; Mashinistov, R.; Masik, J.; Maslennikov, A. L.; Mason, L. H.; Massa, L.; Mastrandrea, P.; Mastroberardino, A.; Masubuchi, T.; Mättig, P.; Maurer, J.; Maxfield, S. J.; Maximov, D. A.; Mazini, R.; Maznas, I.; Mazza, S. M.; Mc Fadden, N. C.; Mc Goldrick, G.; Mc Kee, S. P.; McCarn, A.; McCarthy, R. L.; McCarthy, T. G.; McClymont, L. I.; McDonald, E. F.; McFayden, J. A.; McHedlidze, G.; McMahon, S. J.; McNamara, P. C.; McNicol, C. J.; McPherson, R. A.; Meehan, S.; Megy, T. J.; Mehlhase, S.; Mehta, A.; Meideck, T.; Meier, K.; Meirose, B.; Melini, D.; Mellado Garcia, B. R.; Mellenthin, J. D.; Melo, M.; Meloni, F.; Melzer, A.; Menary, S. B.; Meng, L.; Meng, X. T.; Mengarelli, A.; Menke, S.; Meoni, E.; Mergelmeyer, S.; Merlassino, C.; Mermod, P.; Merola, L.; Meroni, C.; Merritt, F. S.; Messina, A.; Metcalfe, J.; Mete, A. S.; Meyer, C.; Meyer, J.-P.; Meyer, J.; Meyer Zu Theenhausen, H.; Miano, F.; Middleton, R. P.; Miglioranzi, S.; Mijović, L.; Mikenberg, G.; Mikestikova, M.; Mikuž, M.; Milesi, M.; Milic, A.; Millar, D. A.; Miller, D. W.; Mills, C.; Milov, A.; Milstead, D. A.; Minaenko, A. A.; Minami, Y.; Minashvili, I. A.; Mincer, A. I.; Mindur, B.; Mineev, M.; Minegishi, Y.; Ming, Y.; Mir, L. M.; Mirto, A.; Mistry, K. P.; Mitani, T.; Mitrevski, J.; Mitsou, V. A.; Miucci, A.; Miyagawa, P. S.; Mizukami, A.; Mjörnmark, J. U.; Mkrtchyan, T.; Mlynarikova, M.; Moa, T.; Mochizuki, K.; Mogg, P.; Mohapatra, S.; Molander, S.; Moles-Valls, R.; Mondragon, M. C.; Mönig, K.; Monk, J.; Monnier, E.; Montalbano, A.; Montejo Berlingen, J.; Monticelli, F.; Monzani, S.; Moore, R. W.; Morange, N.; Moreno, D.; Moreno Llácer, M.; Morettini, P.; Morgenstern, S.; Mori, D.; Mori, T.; Morii, M.; Morinaga, M.; Morisbak, V.; Morley, A. K.; Mornacchi, G.; Morris, J. D.; Morvaj, L.; Moschovakos, P.; Mosidze, M.; Moss, H. J.; Moss, J.; Motohashi, K.; Mount, R.; Mountricha, E.; Moyse, E. J. W.; Muanza, S.; Mueller, F.; Mueller, J.; Mueller, R. S. P.; Muenstermann, D.; Mullen, P.; Mullier, G. A.; Munoz Sanchez, F. J.; Murray, W. J.; Musheghyan, H.; Muškinja, M.; Myagkov, A. G.; Myska, M.; Nachman, B. P.; Nackenhorst, O.; Nagai, K.; Nagai, R.; Nagano, K.; Nagasaka, Y.; Nagata, K.; Nagel, M.; Nagy, E.; Nairz, A. M.; Nakahama, Y.; Nakamura, K.; Nakamura, T.; Nakano, I.; Naranjo Garcia, R. F.; Narayan, R.; Narrias Villar, D. I.; Naryshkin, I.; Naumann, T.; Navarro, G.; Nayyar, R.; Neal, H. A.; Nechaeva, P. Yu.; Neep, T. J.; Negri, A.; Negrini, M.; Nektarijevic, S.; Nellist, C.; Nelson, A.; Nelson, M. E.; Nemecek, S.; Nemethy, P.; Nessi, M.; Neubauer, M. S.; Neumann, M.; Newman, P. R.; Ng, T. Y.; Nguyen Manh, T.; Nickerson, R. B.; Nicolaidou, R.; Nielsen, J.; Nikiforou, N.; Nikolaenko, V.; Nikolic-Audit, I.; Nikolopoulos, K.; Nilsen, J. K.; Nilsson, P.; Ninomiya, Y.; Nisati, A.; Nishu, N.; Nisius, R.; Nitsche, I.; Nitta, T.; Nobe, T.; Noguchi, Y.; Nomachi, M.; Nomidis, I.; Nomura, M. A.; Nooney, T.; Nordberg, M.; Norjoharuddeen, N.; Novgorodova, O.; Nozaki, M.; Nozka, L.; Ntekas, K.; Nurse, E.; Nuti, F.; O'Connor, K.; O'Neil, D. C.; O'Rourke, A. A.; O'Shea, V.; Oakham, F. G.; Oberlack, H.; Obermann, T.; Ocariz, J.; Ochi, A.; Ochoa, I.; Ochoa-Ricoux, J. P.; Oda, S.; Odaka, S.; Oh, A.; Oh, S. H.; Ohm, C. C.; Ohman, H.; Oide, H.; Okawa, H.; Okumura, Y.; Okuyama, T.; Olariu, A.; Oleiro Seabra, L. F.; Olivares Pino, S. A.; Oliveira Damazio, D.; Olszewski, A.; Olszowska, J.; Onofre, A.; Onogi, K.; Onyisi, P. U. E.; Oppen, H.; Oreglia, M. J.; Oren, Y.; Orestano, D.; Orlando, N.; Orr, R. S.; Osculati, B.; Ospanov, R.; Otero Y Garzon, G.; Otono, H.; Ouchrif, M.; Ould-Saada, F.; Ouraou, A.; Oussoren, K. P.; Ouyang, Q.; Owen, M.; Owen, R. E.; Ozcan, V. E.; Ozturk, N.; Pachal, K.; Pacheco Pages, A.; Pacheco Rodriguez, L.; Padilla Aranda, C.; Pagan Griso, S.; Paganini, M.; Paige, F.; Palacino, G.; Palazzo, S.; Palestini, S.; Palka, M.; Pallin, D.; Panagiotopoulou, E. St.; Panagoulias, I.; Pandini, C. E.; Panduro Vazquez, J. G.; Pani, P.; Panitkin, S.; Pantea, D.; Paolozzi, L.; Papadopoulou, Th. D.; Papageorgiou, K.; Paramonov, A.; Paredes Hernandez, D.; Parker, A. J.; Parker, M. A.; Parker, K. A.; Parodi, F.; Parsons, J. A.; Parzefall, U.; Pascuzzi, V. R.; Pasner, J. M.; Pasqualucci, E.; Passaggio, S.; Pastore, Fr.; Pataraia, S.; Pater, J. R.; Pauly, T.; Pearson, B.; Pedraza Lopez, S.; Pedro, R.; Peleganchuk, S. V.; Penc, O.; Peng, C.; Peng, H.; Penwell, J.; Peralva, B. S.; Perego, M. M.; Perepelitsa, D. V.; Peri, F.; Perini, L.; Pernegger, H.; Perrella, S.; Peschke, R.; Peshekhonov, V. D.; Peters, K.; Peters, R. F. Y.; Petersen, B. A.; Petersen, T. C.; Petit, E.; Petridis, A.; Petridou, C.; Petroff, P.; Petrolo, E.; Petrov, M.; Petrucci, F.; Pettersson, N. E.; Peyaud, A.; Pezoa, R.; Phillips, F. H.; Phillips, P. W.; Piacquadio, G.; Pianori, E.; Picazio, A.; Pickering, M. A.; Piegaia, R.; Pilcher, J. E.; Pilkington, A. D.; Pinamonti, M.; Pinfold, J. L.; Pirumov, H.; Pitt, M.; Plazak, L.; Pleier, M.-A.; Pleskot, V.; Plotnikova, E.; Pluth, D.; Podberezko, P.; Poettgen, R.; Poggi, R.; Poggioli, L.; Pogrebnyak, I.; Pohl, D.; Pokharel, I.; Polesello, G.; Poley, A.; Policicchio, A.; Polifka, R.; Polini, A.; Pollard, C. S.; Polychronakos, V.; Pommès, K.; Ponomarenko, D.; Pontecorvo, L.; Popeneciu, G. A.; Portillo Quintero, D. M.; Pospisil, S.; Potamianos, K.; Potrap, I. N.; Potter, C. J.; Potti, H.; Poulsen, T.; Poveda, J.; Pozo Astigarraga, M. E.; Pralavorio, P.; Pranko, A.; Prell, S.; Price, D.; Primavera, M.; Prince, S.; Proklova, N.; Prokofiev, K.; Prokoshin, F.; Protopopescu, S.; Proudfoot, J.; Przybycien, M.; Puri, A.; Puzo, P.; Qian, J.; Qin, G.; Qin, Y.; Quadt, A.; Queitsch-Maitland, M.; Quilty, D.; Raddum, S.; Radeka, V.; Radescu, V.; Radhakrishnan, S. K.; Radloff, P.; Rados, P.; Ragusa, F.; Rahal, G.; Raine, J. A.; Rajagopalan, S.; Rangel-Smith, C.; Rashid, T.; Raspopov, S.; Ratti, M. G.; Rauch, D. M.; Rauscher, F.; Rave, S.; Ravinovich, I.; Rawling, J. H.; Raymond, M.; Read, A. L.; Readioff, N. P.; Reale, M.; Rebuzzi, D. M.; Redelbach, A.; Redlinger, G.; Reece, R.; Reed, R. G.; Reeves, K.; Rehnisch, L.; Reichert, J.; Reiss, A.; Rembser, C.; Ren, H.; Rescigno, M.; Resconi, S.; Resseguie, E. D.; Rettie, S.; Reynolds, E.; Rezanova, O. L.; Reznicek, P.; Rezvani, R.; Richter, R.; Richter, S.; Richter-Was, E.; Ricken, O.; Ridel, M.; Rieck, P.; Riegel, C. J.; Rieger, J.; Rifki, O.; Rijssenbeek, M.; Rimoldi, A.; Rimoldi, M.; Rinaldi, L.; Ripellino, G.; Ristić, B.; Ritsch, E.; Riu, I.; Rizatdinova, F.; Rizvi, E.; Rizzi, C.; Roberts, R. T.; Robertson, S. H.; Robichaud-Veronneau, A.; Robinson, D.; Robinson, J. E. M.; Robson, A.; Rocco, E.; Roda, C.; Rodina, Y.; Rodriguez Bosca, S.; Rodriguez Perez, A.; Rodriguez Rodriguez, D.; Roe, S.; Rogan, C. S.; Røhne, O.; Roloff, J.; Romaniouk, A.; Romano, M.; Romano Saez, S. M.; Romero Adam, E.; Rompotis, N.; Ronzani, M.; Roos, L.; Rosati, S.; Rosbach, K.; Rose, P.; Rosien, N.-A.; Rossi, E.; Rossi, L. P.; Rosten, J. H. N.; Rosten, R.; Rotaru, M.; Rothberg, J.; Rousseau, D.; Rozanov, A.; Rozen, Y.; Ruan, X.; Rubbo, F.; Ruettinger, E. M.; Rühr, F.; Ruiz-Martinez, A.; Rurikova, Z.; Rusakovich, N. A.; Russell, H. L.; Rutherfoord, J. P.; Ruthmann, N.; Ryabov, Y. F.; Rybar, M.; Rybkin, G.; Ryu, S.; Ryzhov, A.; Rzehorz, G. F.; Saavedra, A. F.; Sabato, G.; Sacerdoti, S.; Sadrozinski, H. F.-W.; Sadykov, R.; Safai Tehrani, F.; Saha, P.; Sahinsoy, M.; Saimpert, M.; Saito, M.; Saito, T.; Sakamoto, H.; Sakurai, Y.; Salamanna, G.; Salazar Loyola, J. E.; Salek, D.; Sales de Bruin, P. H.; Salihagic, D.; Salnikov, A.; Salt, J.; Salvatore, D.; Salvatore, F.; Salvucci, A.; Salzburger, A.; Sammel, D.; Sampsonidis, D.; Sampsonidou, D.; Sánchez, J.; Sanchez Martinez, V.; Sanchez Pineda, A.; Sandaker, H.; Sandbach, R. L.; Sander, C. O.; Sandhoff, M.; Sandoval, C.; Sankey, D. P. C.; Sannino, M.; Sano, Y.; Sansoni, A.; Santoni, C.; Santos, H.; Santoyo Castillo, I.; Sapronov, A.; Saraiva, J. G.; Sarrazin, B.; Sasaki, O.; Sato, K.; Sauvan, E.; Savage, G.; Savard, P.; Savic, N.; Sawyer, C.; Sawyer, L.; Saxon, J.; Sbarra, C.; Sbrizzi, A.; Scanlon, T.; Scannicchio, D. A.; Schaarschmidt, J.; Schacht, P.; Schachtner, B. M.; Schaefer, D.; Schaefer, L.; Schaefer, R.; Schaeffer, J.; Schaepe, S.; Schaetzel, S.; Schäfer, U.; Schaffer, A. C.; Schaile, D.; Schamberger, R. D.; Schegelsky, V. A.; Scheirich, D.; Schernau, M.; Schiavi, C.; Schier, S.; Schildgen, L. K.; Schillo, C.; Schioppa, M.; Schlenker, S.; Schmidt-Sommerfeld, K. R.; Schmieden, K.; Schmitt, C.; Schmitt, S.; Schmitz, S.; Schnoor, U.; Schoeffel, L.; Schoening, A.; Schoenrock, B. D.; Schopf, E.; Schott, M.; Schouwenberg, J. F. P.; Schovancova, J.; Schramm, S.; Schuh, N.; Schulte, A.; Schultens, M. J.; Schultz-Coulon, H.-C.; Schulz, H.; Schumacher, M.; Schumm, B. A.; Schune, Ph.; Schwartzman, A.; Schwarz, T. A.; Schweiger, H.; Schwemling, Ph.; Schwienhorst, R.; Schwindling, J.; Sciandra, A.; Sciolla, G.; Scornajenghi, M.; Scuri, F.; Scutti, F.; Searcy, J.; Seema, P.; Seidel, S. C.; Seiden, A.; Seixas, J. M.; Sekhniaidze, G.; Sekhon, K.; Sekula, S. J.; Semprini-Cesari, N.; Senkin, S.; Serfon, C.; Serin, L.; Serkin, L.; Sessa, M.; Seuster, R.; Severini, H.; Sfiligoj, T.; Sforza, F.; Sfyrla, A.; Shabalina, E.; Shaikh, N. W.; Shan, L. Y.; Shang, R.; Shank, J. T.; Shapiro, M.; Shatalov, P. B.; Shaw, K.; Shaw, S. M.; Shcherbakova, A.; Shehu, C. Y.; Shen, Y.; Sherafati, N.; Sherwood, P.; Shi, L.; Shimizu, S.; Shimmin, C. O.; Shimojima, M.; Shipsey, I. P. J.; Shirabe, S.; Shiyakova, M.; Shlomi, J.; Shmeleva, A.; Shoaleh Saadi, D.; Shochet, M. J.; Shojaii, S.; Shope, D. R.; Shrestha, S.; Shulga, E.; Shupe, M. A.; Sicho, P.; Sickles, A. M.; Sidebo, P. E.; Sideras Haddad, E.; Sidiropoulou, O.; Sidoti, A.; Siegert, F.; Sijacki, Dj.; Silva, J.; Silverstein, S. B.; Simak, V.; Simic, L.; Simion, S.; Simioni, E.; Simmons, B.; Simon, M.; Sinervo, P.; Sinev, N. B.; Sioli, M.; Siragusa, G.; Siral, I.; Sivoklokov, S. Yu.; Sjölin, J.; Skinner, M. B.; Skubic, P.; Slater, M.; Slavicek, T.; Slawinska, M.; Sliwa, K.; Slovak, R.; Smakhtin, V.; Smart, B. H.; Smiesko, J.; Smirnov, N.; Smirnov, S. Yu.; Smirnov, Y.; Smirnova, L. N.; Smirnova, O.; Smith, J. W.; Smith, M. N. K.; Smith, R. W.; Smizanska, M.; Smolek, K.; Snesarev, A. A.; Snyder, I. M.; Snyder, S.; Sobie, R.; Socher, F.; Soffer, A.; Søgaard, A.; Soh, D. A.; Sokhrannyi, G.; Solans Sanchez, C. A.; Solar, M.; Soldatov, E. Yu.; Soldevila, U.; Solodkov, A. A.; Soloshenko, A.; Solovyanov, O. V.; Solovyev, V.; Sommer, P.; Son, H.; Sopczak, A.; Sosa, D.; Sotiropoulou, C. L.; Sottocornola, S.; Soualah, R.; Soukharev, A. M.; South, D.; Sowden, B. C.; Spagnolo, S.; Spalla, M.; Spangenberg, M.; Spanò, F.; Sperlich, D.; Spettel, F.; Spieker, T. M.; Spighi, R.; Spigo, G.; Spiller, L. A.; Spousta, M.; St. Denis, R. D.; Stabile, A.; Stamen, R.; Stamm, S.; Stanecka, E.; Stanek, R. W.; Stanescu, C.; Stanitzki, M. M.; Stapf, B. S.; Stapnes, S.; Starchenko, E. A.; Stark, G. H.; Stark, J.; Stark, S. H.; Staroba, P.; Starovoitov, P.; Stärz, S.; Staszewski, R.; Stegler, M.; Steinberg, P.; Stelzer, B.; Stelzer, H. J.; Stelzer-Chilton, O.; Stenzel, H.; Stevenson, T. J.; Stewart, G. A.; Stockton, M. C.; Stoebe, M.; Stoicea, G.; Stolte, P.; Stonjek, S.; Stradling, A. R.; Straessner, A.; Stramaglia, M. E.; Strandberg, J.; Strandberg, S.; Strauss, M.; Strizenec, P.; Ströhmer, R.; Strom, D. M.; Stroynowski, R.; Strubig, A.; Stucci, S. A.; Stugu, B.; Styles, N. A.; Su, D.; Su, J.; Suchek, S.; Sugaya, Y.; Suk, M.; Sulin, V. V.; Sultan, D. M. S.; Sultansoy, S.; Sumida, T.; Sun, S.; Sun, X.; Suruliz, K.; Suster, C. J. E.; Sutton, M. R.; Suzuki, S.; Svatos, M.; Swiatlowski, M.; Swift, S. P.; Sykora, I.; Sykora, T.; Ta, D.; Tackmann, K.; Taenzer, J.; Taffard, A.; Tafirout, R.; Tahirovic, E.; Taiblum, N.; Takai, H.; Takashima, R.; Takasugi, E. H.; Takeda, K.; Takeshita, T.; Takubo, Y.; Talby, M.; Talyshev, A. A.; Tanaka, J.; Tanaka, M.; Tanaka, R.; Tanaka, S.; Tanioka, R.; Tannenwald, B. B.; Tapia Araya, S.; Tapprogge, S.; Tarem, S.; Tartarelli, G. F.; Tas, P.; Tasevsky, M.; Tashiro, T.; Tassi, E.; Tavares Delgado, A.; Tayalati, Y.; Taylor, A. C.; Taylor, A. J.; Taylor, G. N.; Taylor, P. T. E.; Taylor, W.; Teixeira-Dias, P.; Temple, D.; Ten Kate, H.; Teng, P. K.; Teoh, J. J.; Tepel, F.; Terada, S.; Terashi, K.; Terron, J.; Terzo, S.; Testa, M.; Teuscher, R. J.; Thais, S. J.; Theveneaux-Pelzer, T.; Thiele, F.; Thomas, J. P.; Thomas-Wilsker, J.; Thompson, P. D.; Thompson, A. S.; Thomsen, L. A.; Thomson, E.; Tian, Y.; Tibbetts, M. J.; Ticse Torres, R. E.; Tikhomirov, V. O.; Tikhonov, Yu. A.; Timoshenko, S.; Tipton, P.; Tisserant, S.; Todome, K.; Todorova-Nova, S.; Todt, S.; Tojo, J.; Tokár, S.; Tokushuku, K.; Tolley, E.; Tomlinson, L.; Tomoto, M.; Tompkins, L.; Toms, K.; Tong, B.; Tornambe, P.; Torrence, E.; Torres, H.; Torró Pastor, E.; Toth, J.; Touchard, F.; Tovey, D. R.; Treado, C. J.; Trefzger, T.; Tresoldi, F.; Tricoli, A.; Trigger, I. M.; Trincaz-Duvoid, S.; Tripiana, M. F.; Trischuk, W.; Trocmé, B.; Trofymov, A.; Troncon, C.; Trottier-McDonald, M.; Trovatelli, M.; Truong, L.; Trzebinski, M.; Trzupek, A.; Tsang, K. W.; Tseng, J. C.-L.; Tsiareshka, P. V.; Tsipolitis, G.; Tsirintanis, N.; Tsiskaridze, S.; Tsiskaridze, V.; Tskhadadze, E. G.; Tsukerman, I. I.; Tsulaia, V.; Tsuno, S.; Tsybychev, D.; Tu, Y.; Tudorache, A.; Tudorache, V.; Tulbure, T. T.; Tuna, A. N.; Turchikhin, S.; Turgeman, D.; Turk Cakir, I.; Turra, R.; Tuts, P. M.; Ucchielli, G.; Ueda, I.; Ughetto, M.; Ukegawa, F.; Unal, G.; Undrus, A.; Unel, G.; Ungaro, F. C.; Unno, Y.; Uno, K.; Unverdorben, C.; Urban, J.; Urquijo, P.; Urrejola, P.; Usai, G.; Usui, J.; Vacavant, L.; Vacek, V.; Vachon, B.; Vadla, K. O. H.; Vaidya, A.; Valderanis, C.; Valdes Santurio, E.; Valente, M.; Valentinetti, S.; Valero, A.; Valéry, L.; Valkar, S.; Vallier, A.; Valls Ferrer, J. A.; van den Wollenberg, W.; van der Graaf, H.; van Gemmeren, P.; van Nieuwkoop, J.; van Vulpen, I.; van Woerden, M. C.; Vanadia, M.; Vandelli, W.; Vaniachine, A.; Vankov, P.; Vardanyan, G.; Vari, R.; Varnes, E. W.; Varni, C.; Varol, T.; Varouchas, D.; Vartapetian, A.; Varvell, K. E.; Vasquez, J. G.; Vasquez, G. A.; Vazeille, F.; Vazquez Furelos, D.; Vazquez Schroeder, T.; Veatch, J.; Veeraraghavan, V.; Veloce, L. M.; Veloso, F.; Veneziano, S.; Ventura, A.; Venturi, M.; Venturi, N.; Venturini, A.; Vercesi, V.; Verducci, M.; Verkerke, W.; Vermeulen, A. T.; Vermeulen, J. C.; Vetterli, M. C.; Viaux Maira, N.; Viazlo, O.; Vichou, I.; Vickey, T.; Vickey Boeriu, O. E.; Viehhauser, G. H. A.; Viel, S.; Vigani, L.; Villa, M.; Villaplana Perez, M.; Vilucchi, E.; Vincter, M. G.; Vinogradov, V. B.; Vishwakarma, A.; Vittori, C.; Vivarelli, I.; Vlachos, S.; Vogel, M.; Vokac, P.; Volpi, G.; von der Schmitt, H.; von Toerne, E.; Vorobel, V.; Vorobev, K.; Vos, M.; Voss, R.; Vossebeld, J. H.; Vranjes, N.; Vranjes Milosavljevic, M.; Vrba, V.; Vreeswijk, M.; Vuillermet, R.; Vukotic, I.; Wagner, P.; Wagner, W.; Wagner-Kuhr, J.; Wahlberg, H.; Wahrmund, S.; Walder, J.; Walker, R.; Walkowiak, W.; Wallangen, V.; Wang, C.; Wang, C.; Wang, F.; Wang, H.; Wang, H.; Wang, J.; Wang, J.; Wang, Q.; Wang, R.-J.; Wang, R.; Wang, S. M.; Wang, T.; Wang, W.; Wang, W.; Wang, Z.; Wanotayaroj, C.; Warburton, A.; Ward, C. P.; Wardrope, D. R.; Washbrook, A.; Watkins, P. M.; Watson, A. T.; Watson, M. F.; Watts, G.; Watts, S.; Waugh, B. M.; Webb, A. F.; Webb, S.; Weber, M. S.; Weber, S. M.; Weber, S. W.; Weber, S. A.; Webster, J. S.; Weidberg, A. R.; Weinert, B.; Weingarten, J.; Weirich, M.; Weiser, C.; Weits, H.; Wells, P. S.; Wenaus, T.; Wengler, T.; Wenig, S.; Wermes, N.; Werner, M. D.; Werner, P.; Wessels, M.; Weston, T. D.; Whalen, K.; Whallon, N. L.; Wharton, A. M.; White, A. S.; White, A.; White, M. J.; White, R.; Whiteson, D.; Whitmore, B. W.; Wickens, F. J.; Wiedenmann, W.; Wielers, M.; Wiglesworth, C.; Wiik-Fuchs, L. A. M.; Wildauer, A.; Wilk, F.; Wilkens, H. G.; Williams, H. H.; Williams, S.; Willis, C.; Willocq, S.; Wilson, J. A.; Wingerter-Seez, I.; Winkels, E.; Winklmeier, F.; Winston, O. J.; Winter, B. T.; Wittgen, M.; Wobisch, M.; Wolf, A.; Wolf, T. M. H.; Wolff, R.; Wolter, M. W.; Wolters, H.; Wong, V. W. S.; Woods, N. L.; Worm, S. D.; Wosiek, B. K.; Wotschack, J.; Wozniak, K. W.; Wu, M.; Wu, S. L.; Wu, X.; Wu, Y.; Wyatt, T. R.; Wynne, B. M.; Xella, S.; Xi, Z.; Xia, L.; Xu, D.; Xu, L.; Xu, T.; Xu, W.; Yabsley, B.; Yacoob, S.; Yamaguchi, D.; Yamaguchi, Y.; Yamamoto, A.; Yamamoto, S.; Yamanaka, T.; Yamane, F.; Yamatani, M.; Yamazaki, T.; Yamazaki, Y.; Yan, Z.; Yang, H.; Yang, H.; Yang, Y.; Yang, Z.; Yao, W.-M.; Yap, Y. C.; Yasu, Y.; Yatsenko, E.; Yau Wong, K. H.; Ye, J.; Ye, S.; Yeletskikh, I.; Yigitbasi, E.; Yildirim, E.; Yorita, K.; Yoshihara, K.; Young, C.; Young, C. J. S.; Yu, J.; Yu, J.; Yuen, S. P. Y.; Yusuff, I.; Zabinski, B.; Zacharis, G.; Zaidan, R.; Zaitsev, A. M.; Zakharchuk, N.; Zalieckas, J.; Zaman, A.; Zambito, S.; Zanzi, D.; Zeitnitz, C.; Zemaityte, G.; Zemla, A.; Zeng, J. C.; Zeng, Q.; Zenin, O.; Ženiš, T.; Zerwas, D.; Zhang, D.; Zhang, D.; Zhang, F.; Zhang, G.; Zhang, H.; Zhang, J.; Zhang, L.; Zhang, L.; Zhang, M.; Zhang, P.; Zhang, R.; Zhang, R.; Zhang, X.; Zhang, Y.; Zhang, Z.; Zhao, X.; Zhao, Y.; Zhao, Z.; Zhemchugov, A.; Zhou, B.; Zhou, C.; Zhou, L.; Zhou, M.; Zhou, M.; Zhou, N.; Zhu, C. G.; Zhu, H.; Zhu, J.; Zhu, Y.; Zhuang, X.; Zhukov, K.; Zibell, A.; Zieminska, D.; Zimine, N. I.; Zimmermann, C.; Zimmermann, S.; Zinonos, Z.; Zinser, M.; Ziolkowski, M.; Živković, L.; Zobernig, G.; Zoccoli, A.; Zou, R.; Zur Nedden, M.; Zwalinski, L.; Atlas Collaboration

    2018-02-01

    A detailed study of multiparticle azimuthal correlations is presented using p p data at √{s }=5.02 and 13 TeV, and p +Pb data at √{sNN}=5.02 TeV, recorded with the ATLAS detector at the CERN Large Hadron Collider. The azimuthal correlations are probed using four-particle cumulants cn{4 } and flow coefficients vn{4 } =(-cn{4 } ) 1 /4 for n =2 and 3, with the goal of extracting long-range multiparticle azimuthal correlation signals and suppressing the short-range correlations. The values of cn{4 } are obtained as a function of the average number of charged particles per event, Nch>">Nch, using the recently proposed two-subevent and three-subevent cumulant methods, and compared with results obtained with the standard cumulant method. The standard method is found to be strongly biased by short-range correlations, which originate mostly from jets with a positive contribution to cn{4 } . The three-subevent method, on the other hand, is found to be least sensitive to short-range correlations. The three-subevent method gives a negative c2{4 } , and therefore a well-defined v2{4 } , nearly independent of method, as expected for long-range collective behavior. Finally, the measured values of v2{4 } and v2{2 } are used to estimate the number of sources relevant for the initial eccentricity in the collision geometry. The results based on the subevent cumulant technique provide direct evidence, in small collision systems, for a long-range collectivity involving many particles distributed across a broad rapidity interval.

  1. A simple method to prolong the service life of radioactive sources for external radiotherapy.

    Science.gov (United States)

    Xu, Yingjie; Tian, Yuan; Dai, Jianrong

    2014-07-08

    A radioactive source is usually replaced and disposed after being used for a certain amount of time (usually a half-life). In this study, a simple method is proposed to prolong its service life. Instead of replacing the used source with a new source of full activity, a new source of less activity is added in the source holder in front of the used one, so that the total activity of two sources is equal to the initial activity of the used source or even higher. Similarly, more sources can be added to the previous ones. Attenuation of front source(s) to the back source(s) was evaluated with exponential attenuation equation, and variation of source-focus distance (SFD) with inverse square law for Leksell 4C Gamma Knife, which served as an example of external radiotherapy units. When the number of front sources increased from 1 to 3, the relative air kerma decreased from 36.5% to 5.0%. Both the attenuation effect and SFD variation contributed to the decrease in air kerma, with the former being the major factor. If the height of the source can be decreased in some way, such as increasing the specific activity of sources, the sources can be used more efficiently. The method prolongs the service life of sources by several factors, and reduces the expense of source exchange and reclamation.

  2. A simple method for solving the Bussian equation for electrical conduction in rocks

    Directory of Open Access Journals (Sweden)

    P. W. J. Glover

    2010-09-01

    Full Text Available One of the most general and effective models for calculating the complex electrical conductivity and relative dielectric permittivity of rocks saturated with pore fluids is that of Bussian. Unlike most models, it is non-linear and cannot be solved algebraically. Consequently, researchers use reiterating numerical routines to obtain a solution of the equation, and then only for the real part of the solution. Here we present a different approach to the solution that uses conformal mapping in the complex plane, and implements it within MapleTM. The method is simple and elegant in that it requires, for example, only 3 lines of code in MapleTM 11 and little programming experience. The approach has been shown to be as precise as using the classical reiterating bisection method for real data implemented in C++ on an ordinary desktop computer to within a probability over 1 in 109. However, the conformal mapping approach is 52 times as fast. We show once more that the Bussian equation breaks down for low fluid conductivities, but recommend it (with the modified Archie's law for use with rocks saturated with high salinity fluids when the matrix is conductive.

  3. A simple method for microtuber production in dioscorea opposita using single nodal segments

    International Nuclear Information System (INIS)

    Li, M.; Wang, Y; Liu, W.; Li, S.

    2015-01-01

    Dioscorea opposita Thunb. (Chinese yam) is an important tuber crop in East Asia because of its dual benefits edible and medicinal properties. Microtubers may provide a feasible alternative to in-vitro-grown plantlets as a means of micropropagation and a way to exchange healthy planting material. In this study, we have developed a simplified culture method for In vitro production of microtubers from D. opposita cv. Tiegun. In this method, microtubers formed in 98% of the internodes of single nodal segments after four weeks of dark-incubation when cultured in MS medium supplemented with 60 g sucrose 1-1 with shaking. Anatomical observations strongly supported the process of tuberization. We also found that 66% of the microtubers produced In vitro sprouted two months after transfer to vermiculite. The protocol presented here provides a simple model for studying the physiological, biochemical, and molecular mechanisms of tuberization in D. opposita, and shows good potential for large-scale production of microtubers as well. (author)

  4. Estimation method of finger tapping dynamics using simple magnetic detection system

    Science.gov (United States)

    Kandori, Akihiko; Sano, Yuko; Miyashita, Tsuyoshi; Okada, Yoshihisa; Irokawa, Masataka; Shima, Keisuke; Tsuji, Toshio; Yokoe, Masaru; Sakoda, Saburo

    2010-05-01

    We have developed the simple estimation method of a finger tapping dynamics model for investigating muscle resistance and stiffness during tapping movement in normal subjects. We measured finger tapping movements of 207 normal subjects using a magnetic finger tapping detection system. Each subject tapped two fingers in time with a metronome at 1, 2, 3, 4, and 5 Hz. The velocity and acceleration values for both the closing and opening tapping data were used to estimate a finger tapping dynamics model. Using the frequency response of the ratio of acceleration to velocity of the mechanical impedance parameters, we estimated the resistance (friction coefficient) and compliance (stiffness). We found two dynamics models for the maximum open position and tap position. In the maximum open position, the extensor muscle resistance was twice as high as the flexor muscle resistance and males had a higher spring constant. In the tap position, the flexor muscle resistance was much higher than the extensor muscle resistance. This indicates that the tapping dynamics in the maximum open position are controlled by the balance of extensor and flexor muscle friction resistances and the flexor stiffness, and the flexor friction resistance is the main component in the tap position. It can be concluded that our estimation method makes it possible to understand the tapping dynamics.

  5. Estimation method of finger tapping dynamics using simple magnetic detection system.

    Science.gov (United States)

    Kandori, Akihiko; Sano, Yuko; Miyashita, Tsuyoshi; Okada, Yoshihisa; Irokawa, Masataka; Shima, Keisuke; Tsuji, Toshio; Yokoe, Masaru; Sakoda, Saburo

    2010-05-01

    We have developed the simple estimation method of a finger tapping dynamics model for investigating muscle resistance and stiffness during tapping movement in normal subjects. We measured finger tapping movements of 207 normal subjects using a magnetic finger tapping detection system. Each subject tapped two fingers in time with a metronome at 1, 2, 3, 4, and 5 Hz. The velocity and acceleration values for both the closing and opening tapping data were used to estimate a finger tapping dynamics model. Using the frequency response of the ratio of acceleration to velocity of the mechanical impedance parameters, we estimated the resistance (friction coefficient) and compliance (stiffness). We found two dynamics models for the maximum open position and tap position. In the maximum open position, the extensor muscle resistance was twice as high as the flexor muscle resistance and males had a higher spring constant. In the tap position, the flexor muscle resistance was much higher than the extensor muscle resistance. This indicates that the tapping dynamics in the maximum open position are controlled by the balance of extensor and flexor muscle friction resistances and the flexor stiffness, and the flexor friction resistance is the main component in the tap position. It can be concluded that our estimation method makes it possible to understand the tapping dynamics.

  6. Development of a Rapid and Simple Method to Remove Polyphenols from Plant Extracts

    Directory of Open Access Journals (Sweden)

    Imali Ranatunge

    2017-01-01

    Full Text Available Polyphenols are secondary metabolites of plants, which are responsible for prevention of many diseases. Polyvinylpolypyrrolidone (PVPP has a high affinity towards polyphenols. This method involves the use of PVPP column to remove polyphenols under centrifugal force. Standards of gallic acid, epigallocatechin gallate, vanillin, and tea extracts (Camellia sinensis were used in this study. PVPP powder was packed in a syringe with different quantities. The test samples were layered over the PVPP column and subjected to centrifugation. Supernatant was tested for the total phenol content. The presence of phenolic compounds and caffeine was screened by HPLC and measuring the absorbance at 280. The antioxidant capacity of standards and tea extracts was compared with the polyphenol removed fractions using DPPH scavenging assay. No polyphenols were found in polyphenolic standards or tea extracts after PVPP treatment. The method described in the present study to remove polyphenols is simple, inexpensive, rapid, and efficient and can be employed to investigate the contribution of polyphenols present in natural products to their biological activity.

  7. High Operating Voltage Supercapacitor Using PPy/AC Composite Electrode Based on Simple Dipping Method

    Directory of Open Access Journals (Sweden)

    Kyoungho Kim

    2015-01-01

    Full Text Available As various wearable devices are emerging, self-generated power sources, such as piezoelectric generators, triboelectric generators, and thermoelectric generators, are of interest. To adapt self-generated power sources for application devices, a supercapacitor is necessary because of the short generation times (1–10 ms and low generated power (1–100 μW of self-generated power sources. However, to date, supercapacitors are too large to be adapted for wearable devices. There have been many efforts to reduce the size of supercapacitors by using polypyrrole (PPy for high energy supercapacitor electrodes. However, these supercapacitors have several disadvantages, such as a low operating voltage due to the use of an aqueous electrolyte, and complex manufacturing methods, such as the hydrogel and aerosol methods. In particular, the low operating voltage (~1.0 V is a significant issue because most electronic components operate above 3.0 V. In this study, we successfully demonstrated the high operating voltage (3.0 V of a supercapacitor using a PPy/activated carbon (AC composite electrode based on the chemical polymerization of the PPy by simple dipping. In addition, a twofold enhancement of its energy density was achieved compared with conventional supercapacitors using AC electrodes.

  8. A Simple Method to Measure Renal Function in Swine by the Plasma Clearance of Iohexol

    Science.gov (United States)

    Luis-Lima, Sergio; García-Contreras, Consolación; Carrara, Fabiola; Negrín-Mena, Natalia; Jiménez-Sosa, Alejandro; Jiménez-Hernández, Hugo; Porrini, Esteban

    2018-01-01

    There is no simple method to measure glomerular filtration rate (GFR) in swine, an established model for studying renal disease. We developed a protocol to measure GFR in conscious swine by using the plasma clearance of iohexol. We used two groups, test and validation, with eight animals each. Ten milliliters of iohexol (6.47 g) was injected into the marginal auricular vein and blood samples (3 mL) were collected from the orbital sinus at different points after injection. GFR was determined using two models: two-compartment (CL2: all samples) and one-compartment (CL1: the last six samples). In the test group, CL1 overestimated CL2 by ~30%: CL2 = 245 ± 93 and CL1 = 308 ± 123 mL/min. This error was corrected by a first-order polynomial quadratic equation to CL1, which was considered the simplified method: SM = −47.909 + (1.176xCL1) − (0.00063968xCL12). The SM showed narrow limits of agreement with CL2, a concordance correlation of 0.97, and a total deviation index of 14.73%. Similar results were obtained for the validation group. This protocol is reliable, reproducible, can be performed in conscious animals, uses a single dose of the marker, and requires a reduced number of samples, and avoids urine collection. Finally, it presents a significant improvement in animal welfare conditions and handling necessities in experimental trials. PMID:29329247

  9. A simple method to back-project isocenter dose of radiotherapy treatments using EPID transit dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, T.B.; Cerbaro, B.Q.; Rosa, L.A.R. da, E-mail: thiago.fisimed@gmail.com, E-mail: tbsilveira@inca.gov.br [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro - RJ (Brazil)

    2017-07-01

    The aim of this work was to implement a simple algorithm to evaluate isocenter dose in a phantom using the back-projected transmitted dose acquired using an Electronic Portal Imaging Device (EPID) available in a Varian Trilogy accelerator with two nominal 6 and 10 MV photon beams. This algorithm was developed in MATLAB language, to calibrate EPID measured dose in absolute dose, using a deconvolution process, and to incorporate all scattering and attenuation contributions due to photon interactions with phantom. Modeling process was simplified by using empirical curve adjustments to describe the contribution of scattering and attenuation effects. The implemented algorithm and method were validated employing 19 patient treatment plans with 104 clinical irradiation fields projected on the phantom used. Results for EPID absolute dose calibration by deconvolution have showed percent deviations lower than 1%. Final method validation presented average percent deviations between isocenter doses calculated by back-projection and isocenter doses determined with ionization chamber of 1,86% (SD of 1,00%) and -0,94% (SD of 0,61%) for 6 and 10 MV, respectively. Normalized field by field analysis showed deviations smaller than 2% for 89% of all data for 6 MV beams and 94% for 10 MV beams. It was concluded that the proposed algorithm possesses sufficient accuracy to be used for in vivo dosimetry, being sensitive to detect dose delivery errors bigger than 3-4% for conformal and intensity modulated radiation therapy techniques. (author)

  10. Fabricating superhydrophobic polymer surfaces with excellent abrasion resistance by a simple lamination templating method.

    Science.gov (United States)

    Xu, Qian Feng; Mondal, Bikash; Lyons, Alan M

    2011-09-01

    Fabricating robust superhydrophobic surfaces for commercial applications is challenging as the fine-scale surface features, necessary to achieve superhydrophobicity, are susceptible to mechanical damage. Herein, we report a simple and inexpensive lamination templating method to create superhydrophobic polymer surfaces with excellent abrasion resistance and water pressure stability. To fabricate the surfaces, polyethylene films were laminated against woven wire mesh templates. After cooling, the mesh was peeled from the polymer creating a 3D array of ordered polymer microposts on the polymer surface. The resulting texture is monolithic with the polymer film and requires no chemical modification to exhibit superhydrophobicity. By controlling lamination parameters and mesh dimensions, polyethylene surfaces were fabricated that exhibit static contact angles of 160° and slip angles of 5°. Chemical and mechanical stability was evaluated using an array of manual tests as well as a standard reciprocating abraser test. Surfaces remained superhydrophobic after more than 5500 abrasion cycles at a pressure of 32.0 kPa. In addition, the surface remains dry after immersing into water for 5 h at 55 kPa. This method is environmental friendly, as it employs no solvents or harsh chemicals and may provide an economically viable path to manufacture large areas of mechanically robust superhydrophobic surfaces from inexpensive polymers and reusable templates.

  11. A Simple Method to Measure Renal Function in Swine by the Plasma Clearance of Iohexol

    Directory of Open Access Journals (Sweden)

    Sergio Luis-Lima

    2018-01-01

    Full Text Available There is no simple method to measure glomerular filtration rate (GFR in swine, an established model for studying renal disease. We developed a protocol to measure GFR in conscious swine by using the plasma clearance of iohexol. We used two groups, test and validation, with eight animals each. Ten milliliters of iohexol (6.47 g was injected into the marginal auricular vein and blood samples (3 mL were collected from the orbital sinus at different points after injection. GFR was determined using two models: two-compartment (CL2: all samples and one-compartment (CL1: the last six samples. In the test group, CL1 overestimated CL2 by ~30%: CL2 = 245 ± 93 and CL1 = 308 ± 123 mL/min. This error was corrected by a first-order polynomial quadratic equation to CL1, which was considered the simplified method: SM = −47.909 + (1.176xCL1 − (0.00063968xCL12. The SM showed narrow limits of agreement with CL2, a concordance correlation of 0.97, and a total deviation index of 14.73%. Similar results were obtained for the validation group. This protocol is reliable, reproducible, can be performed in conscious animals, uses a single dose of the marker, and requires a reduced number of samples, and avoids urine collection. Finally, it presents a significant improvement in animal welfare conditions and handling necessities in experimental trials.

  12. Verification of chemistry reference ranges using a simple method in sub-Saharan Africa

    Directory of Open Access Journals (Sweden)

    Irith De Baetselier

    2016-10-01

    Full Text Available Background: Chemistry safety assessments are interpreted by using chemistry reference ranges (CRRs. Verification of CRRs is time consuming and often requires a statistical background. Objectives: We report on an easy and cost-saving method to verify CRRs. Methods: Using a former method introduced by Sigma Diagnostics, three study sites in sub- Saharan Africa, Bondo, Kenya, and Pretoria and Bloemfontein, South Africa, verified the CRRs for hepatic and renal biochemistry assays performed during a clinical trial of HIV antiretroviral pre-exposure prophylaxis. The aspartate aminotransferase/alanine aminotransferase, creatinine and phosphorus results from 10 clinically-healthy participants at the screening visit were used. In the event the CRRs did not pass the verification, new CRRs had to be calculated based on 40 clinically-healthy participants. Results: Within a few weeks, the study sites accomplished verification of the CRRs without additional costs. The aspartate aminotransferase reference ranges for the Bondo, Kenya site and the alanine aminotransferase reference ranges for the Pretoria, South Africa site required adjustment. The phosphorus CRR passed verification and the creatinine CRR required adjustment at every site. The newly-established CRR intervals were narrower than the CRRs used previously at these study sites due to decreases in the upper limits of the reference ranges. As a result, more toxicities were detected. Conclusion: To ensure the safety of clinical trial participants, verification of CRRs should be standard practice in clinical trials conducted in settings where the CRR has not been validated for the local population. This verification method is simple, inexpensive, and can be performed by any medical laboratory.

  13. A simple, reproducible and sensitive spectrophotometric method to estimate microalgal lipids

    Energy Technology Data Exchange (ETDEWEB)

    Chen Yimin [ChELSI Institute, Department of Chemical and Biological Engineering, University of Sheffield, Sheffield S1 3JD (United Kingdom); Vaidyanathan, Seetharaman, E-mail: s.vaidyanathan@sheffield.ac.uk [ChELSI Institute, Department of Chemical and Biological Engineering, University of Sheffield, Sheffield S1 3JD (United Kingdom)

    2012-04-29

    Highlights: Black-Right-Pointing-Pointer FAs released from lipids form complex with Cu-TEA in chloroform. Black-Right-Pointing-Pointer The FA-Cu-TEA complex gives strong absorbance at 260 nm. Black-Right-Pointing-Pointer The absorbance is sensitive and independent of C-atom number in the FAs (10-18). Black-Right-Pointing-Pointer Microalgal lipid extract and pure FA (such as C16) can both be used as standards. - Abstract: Quantification of total lipids is a necessity for any study of lipid production by microalgae, especially given the current interest in microalgal carbon capture and biofuels. In this study, we employed a simple yet sensitive method to indirectly measure the lipids in microalgae by measuring the fatty acids (FA) after saponification. The fatty acids were reacted with triethanolamine-copper salts (TEA-Cu) and the ternary TEA-Cu-FA complex was detected at 260 nm using a UV-visible spectrometer without any colour developer. The results showed that this method could be used to analyse low levels of lipids in the range of nano-moles from as little as 1 mL of microalgal culture. Furthermore, the structure of the TEA-Cu-FA complex and related reaction process are proposed to better understand this assay. There is no special instrument required and the method is very reproducible. To the best of our knowledge, this is the first report of the use of UV absorbance of copper salts with FA as a method to estimate lipids in algal cultures. It will pave the way for a more convenient assay of lipids in microalgae and can readily be expanded for estimating lipids in other biological systems.

  14. A simple, reproducible and sensitive spectrophotometric method to estimate microalgal lipids

    International Nuclear Information System (INIS)

    Chen Yimin; Vaidyanathan, Seetharaman

    2012-01-01

    Highlights: ► FAs released from lipids form complex with Cu–TEA in chloroform. ► The FA–Cu–TEA complex gives strong absorbance at 260 nm. ► The absorbance is sensitive and independent of C-atom number in the FAs (10–18). ► Microalgal lipid extract and pure FA (such as C16) can both be used as standards. - Abstract: Quantification of total lipids is a necessity for any study of lipid production by microalgae, especially given the current interest in microalgal carbon capture and biofuels. In this study, we employed a simple yet sensitive method to indirectly measure the lipids in microalgae by measuring the fatty acids (FA) after saponification. The fatty acids were reacted with triethanolamine–copper salts (TEA–Cu) and the ternary TEA–Cu–FA complex was detected at 260 nm using a UV–visible spectrometer without any colour developer. The results showed that this method could be used to analyse low levels of lipids in the range of nano-moles from as little as 1 mL of microalgal culture. Furthermore, the structure of the TEA–Cu–FA complex and related reaction process are proposed to better understand this assay. There is no special instrument required and the method is very reproducible. To the best of our knowledge, this is the first report of the use of UV absorbance of copper salts with FA as a method to estimate lipids in algal cultures. It will pave the way for a more convenient assay of lipids in microalgae and can readily be expanded for estimating lipids in other biological systems.

  15. A simple method to estimate radiation interception by nursery stock conifers: a case study of eastern white cedar

    NARCIS (Netherlands)

    Pronk, A.A.; Goudriaan, J.; Stilma, E.S.C.; Challa, H.

    2003-01-01

    A simple method was developed to estimate the fraction radiation intercepted by small eastern white cedar plants (Thuja occidentalis 'Brabant'). The method, which describes the crop canopy as rows of cuboids, was compared with methods used for estimating radiation interception by crops with

  16. A simple method for controlling the line width of SASE X-ray FELs

    International Nuclear Information System (INIS)

    Geloni, Gianluca; Kocharyan, Vitali; Saldin, Evgeni

    2010-04-01

    This paper describes a novel single-bunch self-seeding scheme for generating highly monochromatic X-rays from a baseline XFEL undulator. A self-seeded XFEL consists of two undulators with an X-ray monochromator located between them. Previous self-seeding schemes made use of a four-crystal fixed-exit monochromator in Bragg geometry. In such monochromator the X-ray pulse acquires a cm-long path delay, which must be compensated. For a single-bunch self-seeding scheme this requires a long electron beam bypass, implying modifications of the baseline undulator configuration. To avoid this problem, a double bunch self-seeding scheme based on a special photoinjector setup was recently proposed. At variance, here we propose a new time-domain method of monochromatization exploiting a single crystal in the transmission direction, thus avoiding the problem of extra-path delay for the X-ray pulse. The method can be realized using a temporal windowing technique, requiring a magnetic delay for the electron bunch only. When the incident X-ray beam satisfies the Bragg diffraction condition, multiple scattering takes place and the transmittance spectrum in the crystal exhibits an absorption resonance with a narrow linewidth. Then, the temporal waveform of the transmitted radiation pulse is characterized by a long monochromatic wake. The radiation power within this wake is much larger than the shot noise power. At the entrance of the second undulator, the monochromatic wake of the radiation pulse is combined with the delayed electron bunch, and amplified up to saturation level. The proposed setup is extremely simple and composed of as few as two simple elements. These are the crystal and the short magnetic chicane, which accomplishes three tasks by itself. It creates an offset for crystal installation, it removes the electron micro-bunching produced in the first undulator, and it acts as a delay line for temporal windowing. Using a single crystal installed within a short magnetic

  17. Simple method of dynamic Young’s modulus determination in lime and cement mortars

    Directory of Open Access Journals (Sweden)

    Rosell, J. R.

    2011-03-01

    Full Text Available The present work explains a simple method to determine the dynamic Young module (MOE by inducing a set of small mechanical perturbation to samples of lime and cement mortars and correlating the results obtained with results determined using other techniques and methods. The procedure described herein follows the instructions stated in the UNE-EN ISO 12680-1 standard for refractory products although in this study the instructions are applied to standardized RILEM 4x4x16 cm test samples made of lime and cement mortars. In addition, MOE determinations are obtained by using ultrasonic impulse velocity while static Young's modulus determinations are obtained by performing conventional bending tests. The ability of this procedure to correlate with results from other techniques, along with its simplicity, suggests that it can be widely adapted to determine the deformability of mortars under load using standardized samples.

    El presente trabajo muestra un método simple para determinar el módulo de Young dinámico (MOE a partir de pequeñas perturbaciones mecánicas producidas a probetas de mortero de cal y de cemento, correlacionando los resultados obtenidos con las correspondientes mediciones realizadas con otras técnicas. El procedimiento sigue básicamente las instrucciones fijadas en la norma UNE-EN ISO 12680-1 de productos refractarios, pero aplicándolo a probetas normalizadas RILEM 4x4x16 de morteros confeccionados con cal y cemento. Paralelamente se realizan determinaciones del MOE a partir de la velocidad de paso de impulsos ultrasónicos y determinaciones del módulo de Young estático a partir de ensayos de flexión convencionales. La simplicidad del método aplicado y la correlación de los resultados obtenidos con las variables medidas permiten concluir que esta metodología es de aplicación directa para determinar la deformabilidad bajo carga de los morteros a partir de probetas normalizadas.

  18. Verification of chemistry reference ranges using a simple method in sub-Saharan Africa.

    Science.gov (United States)

    De Baetselier, Irith; Taylor, Douglas; Mandala, Justin; Nanda, Kavita; Van Campenhout, Christel; Agingu, Walter; Madurai, Lorna; Barsch, Eva-Maria; Deese, Jennifer; Van Damme, Lut; Crucitti, Tania

    2016-01-01

    Chemistry safety assessments are interpreted by using chemistry reference ranges (CRRs). Verification of CRRs is time consuming and often requires a statistical background. We report on an easy and cost-saving method to verify CRRs. Using a former method introduced by Sigma Diagnostics, three study sites in sub-Saharan Africa, Bondo, Kenya, and Pretoria and Bloemfontein, South Africa, verified the CRRs for hepatic and renal biochemistry assays performed during a clinical trial of HIV antiretroviral pre-exposure prophylaxis. The aspartate aminotransferase/alanine aminotransferase, creatinine and phosphorus results from 10 clinically-healthy participants at the screening visit were used. In the event the CRRs did not pass the verification, new CRRs had to be calculated based on 40 clinically-healthy participants. Within a few weeks, the study sites accomplished verification of the CRRs without additional costs. The aspartate aminotransferase reference ranges for the Bondo, Kenya site and the alanine aminotransferase reference ranges for the Pretoria, South Africa site required adjustment. The phosphorus CRR passed verification and the creatinine CRR required adjustment at every site. The newly-established CRR intervals were narrower than the CRRs used previously at these study sites due to decreases in the upper limits of the reference ranges. As a result, more toxicities were detected. To ensure the safety of clinical trial participants, verification of CRRs should be standard practice in clinical trials conducted in settings where the CRR has not been validated for the local population. This verification method is simple, inexpensive, and can be performed by any medical laboratory.

  19. A simple and convenient method for the simultaneous in vitro study of metformin and glimepiride tablets.

    Science.gov (United States)

    Ahmed, Rehan

    2014-11-01

    A simple and convenient method was developed for the simultaneous determination of metformin HCl and glimepiride in tablet dosage form of different pharmaceuticals companies. This method was validated and proved to be applicable for assay determination in intermediate and finished staged. More over a single medium dissolution of metformin HCl and glimepiride was established and the media was evaluated for comparative studies for different formulations. Reverse phase HPLC equipped with UV detector was used for the determination of metformin HCl and glimepiride. A mixture of acetonitrile and ammonium acetate buffer 0.05M pH 3.0 was used as mobile phase at flow rate of 1.0ml/min. Promocil C18 5µ 100Aº 4.6 x 100mm C18 silica column was used and detection was carried out at 270nm. Method was found to be linear over the range of 4ppm to 16ppm for glimepiride and 170ppm to 680ppm for metformin HCl. Regression co-efficient were found to be 0.9949 and 0.9864 for glimepiride and metformin HCl respectively. Dissolution was performed in 500ml 0.2% sodium lauryl sulfate at 37°C for 45min using paddle apparatus. Dissolution of glimepiride was found to be 98.60% and 101.08% in Orinase Met1 tablet and Amaryl M tablet respectively whereas metformin was found 99.41% and 98.59% in Orinase Met 1 tablet and Amaryl M tablet. RSD for all the dissolutions was less than 2.0% after completion.

  20. A simple and selective method for the separation of Cu radioisotopes from nickel

    Energy Technology Data Exchange (ETDEWEB)

    Fan Xianfeng [School of Physics and Astronomy, University of Birmingham, B15 2TT Birmingham (United Kingdom)]. E-mail: x.fan@bham.ac.uk; Parker, David J. [School of Physics and Astronomy, University of Birmingham, B15 2TT Birmingham (United Kingdom); Smith, Mike D. [School of Physics and Astronomy, University of Birmingham, B15 2TT Birmingham (United Kingdom); Ingram, Andy [School of Physics and Astronomy, University of Birmingham, B15 2TT Birmingham (United Kingdom); Yang Zhufang [School of Physics and Astronomy, University of Birmingham, B15 2TT Birmingham (United Kingdom); Seville, Jonathan P.K. [School of Physics and Astronomy, University of Birmingham, B15 2TT Birmingham (United Kingdom)

    2006-10-15

    Separation of copper radioisotopes from a nickel target is normally performed using solvent extraction or anion exchange rather than using cationic exchange. A commonly held opinion is that cationic exchangers have very similar thermodynamic complexation constants for metallic ions with identical charges, therefore making the separation very difficult or impossible. The results presented in this article indicate that the selectivity of Chelex-100 (a cationic ion exchanger) for Cu radioisotope and Ni ions not only depends on the thermodynamic complexation constant in the resin but also markedly varies with the concentration of mobile H{sup +}. In our developed method, separation of copper radioisotopes from a nickel target was fulfilled in a column filled with Chelex-100 via controlling the HNO{sub 3} concentration of the eluent, and the separation is much more effective, simple and economical in comparison with the common method of anion exchange. For an irradiated nickel target with 650 mg Ni, after separation, the loss of Cu radioisotopes in the nickel portion was reduced from 30% to 0.33% of the total initial radioactivity and the nickel mixed into the radioactive products was reduced from 9.5 to 0.5 mg. This significant improvement will make subsequent labeling much easier and reduce consumption of chelating agents and other chemicals during labeling. If the labeled agent is used in human medical applications, the developed method will significantly decrease the uptake of Ni and chelating agents by patients, therefore reducing both the stress on human body associated with clearing the chemicals from blood and tissue and the risk of various types of acute and chronic disorder due to exposure to Ni.

  1. A simple and rapid method to graft hydroxyapatite on carbon nanotubes

    International Nuclear Information System (INIS)

    Neelgund, Gururaj M.; Olurode, Kehinde; Luo Zhiping; Oki, Aderemi

    2011-01-01

    Herein a simple and effective approach is introduced to functionalize single walled carbon nanotubes (SWCNTs) by in-situ grafting of hydroxyapatite (HA). The pristine SWCNTs were chemically activated through introduction of carboxylic groups on their surfaces by refluxing in the mixture of H 2 SO 4 and HNO 3 . The resulting carboxylated SWCNTs were further utilized for grafting of HA. The Fourier transform infrared and Raman spectroscopic studies demonstrated the formation of HA and its grafting over SWCNTs. The phase composition of HA and existence Ca 2+ and PO 4 3- ions were studied using X-ray diffraction and energy dispersive X-ray analyses, respectively. The surface morphology of functionalized SWCNTs was analyzed using scanning electron microscopy and transmission electron microscopy. Thermogravimetric analysis confirmed the existence of HA on SWCNTs by exhibiting different thermogram for pure HA and functionalized SWCNTs. Overall, this method produced uniform grafting of low crystalline HA on carboxylated SWCNTs with strong interfacial bonding. - Graphical abstract: A facile approach is demonstrated for effective functionalization of single walled carbon nanotubes (SWCNTs) by in-situ grafting of hydroxyapatite (HA) to improve hydrophilicity and biocompatibility of SWCNTs. This method produced uniform grafting of low crystalline HA on carboxylated SWCNTs with strong interfacial bonding. Research highlights: → This method is facile and effective to graft HA on SWCNTs. → As f-SWCNTs is a promising biomaterial to use without any further processing → This technique is economic, easy to repeat and can be optimized for mass production. → Ratio of Ca to P in f-SWCNTs was 1.65, which is near to ratio present in bone tissue.

  2. A simple and rapid method to graft hydroxyapatite on carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Neelgund, Gururaj M.; Olurode, Kehinde [Department of Chemistry, Prairie View A and M University, Prairie View, TX 77446 (United States); Luo Zhiping [Microscopy and Imaging Center, Materials Science and Engineering, Texas A and M University, College Station TX 77843 (United States); Oki, Aderemi, E-mail: aroki@pvamu.edu [Department of Chemistry, Prairie View A and M University, Prairie View, TX 77446 (United States)

    2011-10-10

    Herein a simple and effective approach is introduced to functionalize single walled carbon nanotubes (SWCNTs) by in-situ grafting of hydroxyapatite (HA). The pristine SWCNTs were chemically activated through introduction of carboxylic groups on their surfaces by refluxing in the mixture of H{sub 2}SO{sub 4} and HNO{sub 3}. The resulting carboxylated SWCNTs were further utilized for grafting of HA. The Fourier transform infrared and Raman spectroscopic studies demonstrated the formation of HA and its grafting over SWCNTs. The phase composition of HA and existence Ca{sup 2+} and PO{sub 4}{sup 3-} ions were studied using X-ray diffraction and energy dispersive X-ray analyses, respectively. The surface morphology of functionalized SWCNTs was analyzed using scanning electron microscopy and transmission electron microscopy. Thermogravimetric analysis confirmed the existence of HA on SWCNTs by exhibiting different thermogram for pure HA and functionalized SWCNTs. Overall, this method produced uniform grafting of low crystalline HA on carboxylated SWCNTs with strong interfacial bonding. - Graphical abstract: A facile approach is demonstrated for effective functionalization of single walled carbon nanotubes (SWCNTs) by in-situ grafting of hydroxyapatite (HA) to improve hydrophilicity and biocompatibility of SWCNTs. This method produced uniform grafting of low crystalline HA on carboxylated SWCNTs with strong interfacial bonding. Research highlights: {yields} This method is facile and effective to graft HA on SWCNTs. {yields} As f-SWCNTs is a promising biomaterial to use without any further processing {yields} This technique is economic, easy to repeat and can be optimized for mass production. {yields} Ratio of Ca to P in f-SWCNTs was 1.65, which is near to ratio present in bone tissue.

  3. Exploratory factor analysis and reliability analysis with missing data: A simple method for SPSS users

    Directory of Open Access Journals (Sweden)

    Bruce Weaver

    2014-09-01

    Full Text Available Missing data is a frequent problem for researchers conducting exploratory factor analysis (EFA or reliability analysis. The SPSS FACTOR procedure allows users to select listwise deletion, pairwise deletion or mean substitution as a method for dealing with missing data. The shortcomings of these methods are well-known. Graham (2009 argues that a much better way to deal with missing data in this context is to use a matrix of expectation maximization (EM covariances(or correlations as input for the analysis. SPSS users who have the Missing Values Analysis add-on module can obtain vectors ofEM means and standard deviations plus EM correlation and covariance matrices via the MVA procedure. But unfortunately, MVA has no /MATRIX subcommand, and therefore cannot write the EM correlations directly to a matrix dataset of the type needed as input to the FACTOR and RELIABILITY procedures. We describe two macros that (in conjunction with an intervening MVA command carry out the data management steps needed to create two matrix datasets, one containing EM correlations and the other EM covariances. Either of those matrix datasets can then be used asinput to the FACTOR procedure, and the EM correlations can also be used as input to RELIABILITY. We provide an example that illustrates the use of the two macros to generate the matrix datasets and how to use those datasets as input to the FACTOR and RELIABILITY procedures. We hope that this simple method for handling missing data will prove useful to both students andresearchers who are conducting EFA or reliability analysis.

  4. A New and Simple Method for Crosstalk Estimation in Homogeneous Trench-Assisted Multi-Core Fibers

    DEFF Research Database (Denmark)

    Ye, Feihong; Tu, Jiajing; Saitoh, Kunimasa

    2014-01-01

    A new and simple method for inter-core crosstalk estimation in homogeneous trench-assisted multi-core fibers is presented. The crosstalk calculated by this method agrees well with experimental measurement data for two kinds of fabricated 12-core fibers.......A new and simple method for inter-core crosstalk estimation in homogeneous trench-assisted multi-core fibers is presented. The crosstalk calculated by this method agrees well with experimental measurement data for two kinds of fabricated 12-core fibers....

  5. Present status and future of simple measuring methods; Suishitsu kan`i sokutei gijutsu no genjo to hatten no hoko

    Energy Technology Data Exchange (ETDEWEB)

    Urano, K.; Ishii, S. [Yokohama National University, Yokohama (Japan)

    1998-05-10

    This paper discusses simple measuring methods for water quality. There are various purposes for measuring water quality. It is not necessary to measure the water quality in an official way by taking a lot of labor and cost. Simple measuring methods are often adopted. By applying simple methods, measuring points and frequency of main discharge processes can be increased, resulting in the detailed evaluation and monitoring. Easy safety check for earth filling waste and soil pollutants is realized. Daily inspection and atmospheric measurements at accidents and disasters are easily promoted. The simple methods require easy and rapid operation, sensibility, accuracy and reproducibility suitable for the purpose, small size apparatus, low cost for measurements, and safety against used harmful matters. Coloring reaction is utilized for most of the measuring principles of simple methods, which include tests using test papers, pack tests, colorimetric tests, and tests using photoelectric colorimeter. The bacteria detection includes titration methods using dropping bottles, tablets and syringes, and tests using test papers. A measuring kit for the enzyme immunity method is commercialized. Cooperation of experts, measuring operators at the site and citizens is also indispensable. 7 refs., 3 figs., 2 tabs.

  6. A Simple and Effective Physical Characteristic Profiling Method for Methamphetamine Tablet Seized in China.

    Science.gov (United States)

    Li, Tao; Hua, Zhendong; Meng, Xin; Liu, Cuimei

    2018-03-01

    Methamphetamine (MA) tablet production confers chemical and physical properties. This study developed a simple and effective physical characteristic profiling method for MA tablets with capital letter "WY" logos, which realized the discrimination between linked and unlinked seizures. Seventeen signature distances extracted from the "WY" logo were explored as factors for multivariate analysis and demonstrated to be effective to represent the features of tablets in the drug intelligence perspective. Receiver operating characteristic (ROC) curve was used to evaluate efficiency of different pretreatments and distance/correlation metrics, while "Standardization + Euclidean" and "Logarithm + Euclidean" algorithms outperformed the rest. Finally, hierarchical cluster analysis (HCA) was applied to the data set of 200 MA tablet seizures randomly selected from cases all around China in 2015, and 76% of them were classified into a group named after "WY-001." Moreover, the "WY-001" tablets occupied 51-80% tablet seizures from 2011 to 2015 in China, indicating the existence of a huge clandestine factory incessantly manufacturing MA tablets. © 2017 American Academy of Forensic Sciences.

  7. Integral design method for simple and small Mars lander system using membrane aeroshell

    Science.gov (United States)

    Sakagami, Ryo; Takahashi, Ryohei; Wachi, Akifumi; Koshiro, Yuki; Maezawa, Hiroyuki; Kasai, Yasko; Nakasuka, Shinichi

    2018-03-01

    To execute Mars surface exploration missions, spacecraft need to overcome the difficulties of the Mars entry, descent, and landing (EDL) sequences. Previous landing missions overcame these challenges with complicated systems that could only be executed by organizations with mature technology and abundant financial resources. In this paper, we propose a novel integral design methodology for a small, simple Mars lander that is achievable even by organizations with limited technology and resources such as universities or emerging countries. We aim to design a lander (including its interplanetary cruise stage) whose size and mass are under 1 m3 and 150 kg, respectively. We adopted only two components for Mars EDL process: a "membrane aeroshell" for the Mars atmospheric entry and descent sequence and one additional mechanism for the landing sequence. The landing mechanism was selected from the following three candidates: (1) solid thrusters, (2) aluminum foam, and (3) a vented airbag. We present a reasonable design process, visualize dependencies among parameters, summarize sizing methods for each component, and propose the way to integrate these components into one system. To demonstrate the effectiveness, we applied this methodology to the actual Mars EDL mission led by the National Institute of Information and Communications Technology (NICT) and the University of Tokyo. As a result, an 80 kg class Mars lander with a 1.75 m radius membrane aeroshell and a vented airbag was designed, and the maximum landing shock that the lander will receive was 115 G.

  8. A Simple and Efficient RNA Extraction Method from Deep-Sea Hydrothermal Vent Chimney Structures.

    Science.gov (United States)

    Muto, Hisashi; Takaki, Yoshihiro; Hirai, Miho; Mino, Sayaka; Sawayama, Shigeki; Takai, Ken; Nakagawa, Satoshi

    2017-12-27

    RNA-based microbiological analyses, e.g., transcriptome and reverse transcription-quantitative PCR, require a relatively large amount of high quality RNA. RNA-based analyses on microbial communities in deep-sea hydrothermal environments often encounter methodological difficulties with RNA extraction due to the presence of unique minerals in and the low biomass of samples. In the present study, we assessed RNA extraction methods for deep-sea vent chimneys that had complex mineral compositions. Mineral-RNA adsorption experiments were conducted using mock chimney minerals and Escherichia coli total RNA solution, and showed that detectable RNA significantly decreased possibly due to adsorption onto minerals. This decrease in RNA was prevented by the addition of sodium tripolyphosphate (STPP), deoxynucleotide triphosphates (dNTPs), salmon sperm DNA, and NaOH. The addition of STPP was also effective for RNA extraction from the mixture of E. coli cells and mock chimney minerals when TRIzol reagent and the RNeasy column were used, but not when the RNeasy PowerSoil total RNA kit was used. A combination of STPP, TRIzol reagent, the RNeasy column, and sonication resulted in the highest RNA yield from a natural chimney. This indirect extraction procedure is simple, rapid, inexpensive, and may be used for large-scale RNA extraction.

  9. A Simple and Rapid Method for Preparing a Cell-Free Bacterial Lysate for Protein Synthesis.

    Directory of Open Access Journals (Sweden)

    Nitzan Krinsky

    Full Text Available Cell-free protein synthesis (CFPS systems are important laboratory tools that are used for various synthetic biology applications. Here, we present a simple and inexpensive laboratory-scale method for preparing a CFPS system from E. coli. The procedure uses basic lab equipment, a minimal set of reagents, and requires less than one hour to process the bacterial cell mass into a functional S30-T7 extract. BL21(DE3 and MRE600 E. coli strains were used to prepare the S30-T7 extract. The CFPS system was used to produce a set of fluorescent and therapeutic proteins of different molecular weights (up to 66 kDa. This system was able to produce 40-150 μg-protein/ml, with variations depending on the plasmid type, expressed protein and E. coli strain. Interestingly, the BL21-based CFPS exhibited stability and increased activity at 40 and 45°C. To the best of our knowledge, this is the most rapid and affordable lab-scale protocol for preparing a cell-free protein synthesis system, with high thermal stability and efficacy in producing therapeutic proteins.

  10. A Simple and Rapid Method for Preparing a Cell-Free Bacterial Lysate for Protein Synthesis

    Science.gov (United States)

    Kaduri, Maya; Shainsky-Roitman, Janna; Goldfeder, Mor; Ivanir, Eran; Benhar, Itai; Shoham, Yuval; Schroeder, Avi

    2016-01-01

    Cell-free protein synthesis (CFPS) systems are important laboratory tools that are used for various synthetic biology applications. Here, we present a simple and inexpensive laboratory-scale method for preparing a CFPS system from E. coli. The procedure uses basic lab equipment, a minimal set of reagents, and requires less than one hour to process the bacterial cell mass into a functional S30-T7 extract. BL21(DE3) and MRE600 E. coli strains were used to prepare the S30-T7 extract. The CFPS system was used to produce a set of fluorescent and therapeutic proteins of different molecular weights (up to 66 kDa). This system was able to produce 40–150 μg-protein/ml, with variations depending on the plasmid type, expressed protein and E. coli strain. Interestingly, the BL21-based CFPS exhibited stability and increased activity at 40 and 45°C. To the best of our knowledge, this is the most rapid and affordable lab-scale protocol for preparing a cell-free protein synthesis system, with high thermal stability and efficacy in producing therapeutic proteins. PMID:27768741

  11. Optical properties of silver sulphide thin films formed on evaporated Ag by a simple sulphurization method

    Energy Technology Data Exchange (ETDEWEB)

    Barrera-Calva, E., E-mail: ebc@xanum.uam.m [Departamento de Ingenieria de Procesos e hidraulica, Universidad Autonoma Metropolitana - Iztapalapa, Av. Purisima Esq. Michoacan, Col. Vicentina, Mexico, D.F., 09340 (Mexico); Ortega-Lopez, M.; Avila-Garcia, A.; Matsumoto-Kwabara, Y. [Departamento de Ingenieria Electrica, Centro de Investigacion y de Estudios Avanzados del IPN, Mexico DF 07360 (Mexico)

    2010-01-31

    Silver sulphide (Ag{sub 2}S) thin films were grown on the surface of silver films (Ag) deposited on glass substrate by using a simple chemical sulphurization method. According to X-ray diffraction analysis, the Ag{sub 2}S thin films display low intensity peaks at 34.48{sup o}, 36.56{sup o}, and 44.28{sup o}, corresponding to diffraction from (100), (112) and (103) planes of the acanthite phase (monoclinic). A model of the type Ag{sub 2}S/Ag/glass was deduced from spectroscopic ellipsometric measurements. Also, the optical constants (n, k) of the system were determined. Furthermore, the optical properties as solar selective absorber for collector applications were assessed. The optical reflectance of the Ag{sub 2}S/Ag thin film systems exhibits the expected behavior for an ideal selective absorber, showing a low reflectance in the wavelength range below 2 {mu}m and a high reflectance for wavelengths higher than that value. An absorptance about 70% and an emittance about 3% or less were calculated for several samples.

  12. A simple method for enzymatic synthesis of unlabeled and radiolabeled Hydroxycinnamate-CoA

    Energy Technology Data Exchange (ETDEWEB)

    Rautergarten, Carsten; Baidoo, Edward; Keasling, Jay; Vibe Scheller, Henrik

    2011-07-20

    Hydroxycinnamate coenzyme A (CoA) thioesters are substrates for biosynthesis of lignin and hydroxycinna- mate esters of polysaccharides and other polymers. Hence, a supply of these substrates is essential for investigation of cell wall biosynthesis. In this study, three recombinant enzymes, caffeic acid 3-O-methyltransferase, 4-coumarate- CoA ligase 1, and 4-coumarate-CoA ligase 5, were cloned from wheat, tobacco, and Arabidopsis, respectively, and were used to synthesize {sup 14}C-feruloyl-CoA, caffeoyl-CoA, p-coumaroyl-CoA, feruloyl-CoA, and sinapoyl-CoA. The corresponding hydroxycinnamoyl-CoA thioesters were high-performance liquid chromatography purified, the only extraction/purification step necessary, with total yields between 88-95%. Radiolabeled {sup 14}C-feruloyl-CoA was generated from caffeic acid and S-adenosyl-{sup 14}C-methionine under the combined action of caffeic acid 3-O-methyltransferase and 4-coumarate-CoA ligase 1. About 70% of {sup 14}C-methyl groups from S-adenosyl methionine were incorporated into the final product. The methods presented are simple, fast, and efficient for the preparation of the hydroxycinnamate thioesters.

  13. Decision Support System to Choose Digital Single Lens Camera with Simple Additive Weighting Method

    Directory of Open Access Journals (Sweden)

    Tri Pina Putri

    2016-11-01

    Full Text Available One of the technologies that evolve today is Digital Single Lens Reflex (DSLR camera. The number of products makes users have difficulties to choose the appropriate camera based on their criteria. Users may utilize several ways to help them choosing the intended camera such as using magazine, internet, and other media. This paper discusses about a web based decision support system to choose cameras by using SAW (Simple Additive Weighting method in order to make the decision process more effective and efficient. This system is expected to give recommendations about the camera which is appropriate with the user’s need and criteria based on the cost, the resolution, the feature, the ISO, and the censor. The system was implemented by using PHP and MySQL. Based on the result of questionnaire distributed to 20 respondents, 60% respondents agree that this decision support system can help users to choose the appropriate camera DSLR in accordance with the user’s need, 60% of respondents agree that this decision support system is more effective to choose DSLR camera and 75% of respondents agree that this system is more efficient. In addition, 60.55% of respondents agree that this system has met 5 Es Usability Framework.

  14. Feasibility of testing DNA repair inhibitors for mutagenicity by a simple method

    International Nuclear Information System (INIS)

    Sideropoulos, A.S.; Specht, S.M.; Jones, M.T.

    1980-01-01

    A simple screening methodology for the determination of mutagenicity of DNA repair inhibitors has been tested in this laboratory. Radiation-resistant E. coli B/r and WP2 hcr + and hcr - are suitable strains for mutagenicity testing. In these strains irradiated with 40-60 ergs/mm 2 , chemicals which interfere with repair of ultraviolet-induced pre-mutational lesions can be shown to enhance significantly the frequency of mutations to streptomycin resistance. This phenomenon is termed 'mutational synergism' [18,20]. We have attempted to apply the procedure for securing data for 'mutational synergism' between ultraviolet (UV) radiation and a number of antimalarial drugs including quinine hydrochloride (50 μg/ml), quinine hydrobromide (50 μg/ml), primaquine diphosphate (50 μg/ml), chloroquine (50 μg/ml), quinine (50 μg/ml) and quinacrine dihydrochloride (25 μg/ml). All drugs tested give synergistic effects with UV light. The synergistic activity ranges from 3- to 35-fold. Quinine and quinacrine dihydrochloride have been found to be much more efficient enhancers of the mutagenic effect of UV than caffeine. In general, we have found that the expression of synergistic action occurs at a concentration well below the minimum inhibitory concentration (MIC) with the drugs tested. The implication of these observations in the establishment of a screening method for the evaluation of the mutagenicity of DNA repair inhibitors is discussed. (orig.)

  15. Simple and high yielding method for preparing tissue specific extracellular matrix coatings for cell culture.

    Science.gov (United States)

    DeQuach, Jessica A; Mezzano, Valeria; Miglani, Amar; Lange, Stephan; Keller, Gordon M; Sheikh, Farah; Christman, Karen L

    2010-09-27

    The native extracellular matrix (ECM) consists of a highly complex, tissue-specific network of proteins and polysaccharides, which help regulate many cellular functions. Despite the complex nature of the ECM, in vitro cell-based studies traditionally assess cell behavior on single ECM component substrates, which do not adequately mimic the in vivo extracellular milieu. We present a simple approach for developing naturally derived ECM coatings for cell culture that provide important tissue-specific cues unlike traditional cell culture coatings, thereby enabling the maturation of committed C2C12 skeletal myoblast progenitors and human embryonic stem cells differentiated into cardiomyocytes. Here we show that natural muscle-specific coatings can (i) be derived from decellularized, solubilized adult porcine muscle, (ii) contain a complex mixture of ECM components including polysaccharides, (iii) adsorb onto tissue culture plastic and (iv) promote cell maturation of committed muscle progenitor and stem cells. This versatile method can create tissue-specific ECM coatings, which offer a promising platform for cell culture to more closely mimic the mature in vivo ECM microenvironment.

  16. A simple method for determining polymeric IgA-containing immune complexes.

    Science.gov (United States)

    Sancho, J; Egido, J; González, E

    1983-06-10

    A simplified assay to measure polymeric IgA-immune complexes in biological fluids is described. The assay is based upon the specific binding of a secretory component for polymeric IgA. In the first step, multimeric IgA (monomeric and polymeric) immune complexes are determined by the standard Raji cell assay. Secondly, labeled secretory component added to the assay is bound to polymeric IgA-immune complexes previously fixed to Raji cells, but not to monomeric IgA immune complexes. To avoid false positives due to possible complement-fixing IgM immune complexes, prior IgM immunoadsorption is performed. Using anti-IgM antiserum coupled to CNBr-activated Sepharose 4B this step is not time-consuming. Polymeric IgA has a low affinity constant and binds weakly to Raji cells, as Scatchard analysis of the data shows. Thus, polymeric IgA immune complexes do not bind to Raji cells directly through Fc receptors, but through complement breakdown products, as with IgG-immune complexes. Using this method, we have been successful in detecting specific polymeric-IgA immune complexes in patients with IgA nephropathy (Berger's disease) and alcoholic liver disease, as well as in normal subjects after meals of high protein content. This new, simple, rapid and reproducible assay might help to study the physiopathological role of polymeric IgA immune complexes in humans and animals.

  17. A simple method to compare firing pin marks using stereomicroscope and Microsoft office (Windows 8) tools.

    Science.gov (United States)

    Suresh, R

    2017-08-01

    Pertinent marks of fired cartridge cases such as firing pin, breech face, extractor, ejector, etc. are used for firearm identification. A non-standard semiautomatic pistol and four .22rim fire cartridges (head stamp KF) is used for known source comparison study. Two test fired cartridge cases are examined under stereomicroscope. The characteristic marks are captured by digital camera and comparative analysis of striation marks is done by using different tools available in the Microsoft word (Windows 8) of a computer system. The similarities of striation marks thus obtained are highly convincing to identify the firearm. In this paper, an effort has been made to study and compare the striation marks of two fired cartridge cases using stereomicroscope, digital camera and computer system. Comparison microscope is not used in this study. The method described in this study is simple, cost effective, transport to field study and can be equipped in a crime scene vehicle to facilitate immediate on spot examination. The findings may be highly helpful to the forensic community, law enforcement agencies and students. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. A Simple Predictive Method of Critical Flicker Detection for Human Healthy Precaution

    Directory of Open Access Journals (Sweden)

    Goh Zai Peng

    2015-01-01

    Full Text Available Interharmonics and flickers have an interrelationship between each other. Based on International Electrotechnical Commission (IEC flicker standard, the critical flicker frequency for a human eye is located at 8.8 Hz. Additionally, eye strains, headaches, and in the worst case seizures may happen due to the critical flicker. Therefore, this paper introduces a worthwhile research gap on the investigation of interrelationship between the amplitudes of the interharmonics and the critical flicker for 50 Hz power system. Consequently, the significant findings obtained in this paper are the amplitudes of two particular interharmonics are able to detect the critical flicker. In this paper, the aforementioned amplitudes are detected by adaptive linear neuron (ADALINE. After that, the critical flicker is detected by substituting the aforesaid amplitudes to the formulas that have been generated in this paper accordingly. Simulation and experimental works are conducted and the accuracy of the proposed algorithm which utilizes ADALINE is similar, as compared to typical Fluke power analyzer. In a nutshell, this simple predictive method for critical flicker detection has strong potential to be applied in any human crowded places (such as offices, shopping complexes, and stadiums for human healthy precaution purpose due to its simplicity.

  19. A simple method for environmental cell depressurization for use with an electron microscope.

    Science.gov (United States)

    Ogawa, Naoki; Mizokawa, Ryo; Saito, Minoru; Ishikawa, Akira

    2017-12-01

    With the aid of the environmental cell (EC) in electron microscopy, hydrated specimens have been observed at high resolutions that optical microscopy cannot attain. Due to the ultra-high vacuum conditions of the inner column of the electron microscope, the EC requires sealing films that are sufficiently thin to allow electron transmission and that are sufficiently tough to withstand the pressure difference between the inside and outside of the EC. However, most hydrated specimens can be observed at low vacuum because the saturated vapor pressure of water is known to be 0.02 atm at room temperature. These concepts have been used in the differential pumping system, but it is complicated and relatively expensive. In this work, we propose a simple method for depressurization of the EC using a 'balloon structure' and demonstrate the theoretical benefits and practical improvement for specimen observations in low-vacuum conditions. © The Author 2017. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  20. A simple finite element method for boundary value problems with a Riemann–Liouville derivative

    KAUST Repository

    Jin, Bangti; Lazarov, Raytcho; Lu, Xiliang; Zhou, Zhi

    2016-01-01

    © 2015 Elsevier B.V. All rights reserved. We consider a boundary value problem involving a Riemann-Liouville fractional derivative of order α∈(3/2,2) on the unit interval (0,1). The standard Galerkin finite element approximation converges slowly due to the presence of singularity term xα-1 in the solution representation. In this work, we develop a simple technique, by transforming it into a second-order two-point boundary value problem with nonlocal low order terms, whose solution can reconstruct directly the solution to the original problem. The stability of the variational formulation, and the optimal regularity pickup of the solution are analyzed. A novel Galerkin finite element method with piecewise linear or quadratic finite elements is developed, and L2(D) error estimates are provided. The approach is then applied to the corresponding fractional Sturm-Liouville problem, and error estimates of the eigenvalue approximations are given. Extensive numerical results fully confirm our theoretical study.

  1. PROPOSED SIMPLE METHOD FOR ELECTROCARDIOGRAM RECORDING IN FREE-RANGING ASIAN ELEPHANTS (ELEPHAS MAXIMUS).

    Science.gov (United States)

    Chai, Norin; Pouchelon, Jean Louis; Bouvard, Jonathan; Sillero, Leonor Camacho; Huynh, Minh; Segalini, Vincent; Point, Lisa; Croce, Veronica; Rigaux, Goulven; Highwood, Jack; Chetboul, Valérie

    2016-03-01

    Electrocardiography represents a relevant diagnostic tool for detecting cardiac disease in animals. Elephants can present various congenital and acquired cardiovascular diseases. However, few electrophysiologic studies have been reported in captive elephants, mainly due to challenging technical difficulties in obtaining good-quality electrocardiogram (ECG) tracings, and no data are currently available for free-ranging Asian elephants (Elephas maximus). The purpose of this pilot prospective study was to evaluate the feasibility of using a simple method for recording ECG tracings in wild, apparently healthy, unsedated Asian elephants (n = 7) in the standing position. Successful six-lead recordings (I, II, III, aVR, aVL, and aVF) were obtained, with the aVL lead providing the best-quality tracings in most animals. Variables measured in the aVL lead included heart rate, amplitudes and duration of the P waves, QRS complexes, T and U waves, and duration of the PR, QT, and QU intervals. A negative deflection following positive P waves, representative of an atrial repolarization wave (Ta wave), was observed for five out of the seven elephants.

  2. Feasibility of testing DNA repair inhibitors for mutagenicity by a simple method

    International Nuclear Information System (INIS)

    Sideropoulos, A.S.; Specht, S.M.; Jones, M.T.

    1980-01-01

    A simple screening methodology for the determination of mutagenictity of DNA repair inhibitors has been tested in this laboratory. Radiation-resistant E. coli B/r and WP2 hcr + and hcr - are suitable strains for mutagenicity testing. In these strains irradiated with 40-60 ergs/mm 2 , chemicals which interfere with repair of ultraviolet-induced pre-mutational lesions can be shown to enhance significantly the frequency of mutations to streptomycin resistance. This phenomenon is termed mutational synergism. We have attempted to apply the procedure for securing data for mutational synergism between ultraviolet (UV) radiation and a number of antimalarial drugs including quinine hydrochloride (50 μg/ml), quinine hydrobromide (50 μg/ml), primaquine diphosphate (50 μg/ml), chloroquine (50μg/ml) and quinacrine dihydrochloride (25 μg/ml). All drugs tested give synergistic effets with UV light. The synergistic activity ranges from 3- to 35-fold. Quinine and quinacrine dihydrochloride have been found to be much more efficient enhancers of the mutagenic effect of UV than caffeine. In general, we have found that the expression of synergistic action occurs at a concentration well below the minimum inhibitory concentration (MIC) with the drugs tested. The implication of these observations in the establishment of a screening method for the evaluation of the mutagenicity of DNA repair inhibitors is discussed. (orig.)

  3. Feasibility of testing DNA repair inhibitors for mutagenicity by a simple method

    Energy Technology Data Exchange (ETDEWEB)

    Sideropoulos, A S; Specht, S M; Jones, M T [Duquesne Univ., Pittsburgh, PA (USA). Dept. of Biological Sciences

    1980-04-01

    A simple screening methodology for the determination of mutagenictity of DNA repair inhibitors has been tested in this laboratory. Radiation-resistant E. coli B/r and WP2 hcr/sup +/ and hcr/sup -/ are suitable strains for mutagenicity testing. In these strains irradiated with 40-60 ergs/mm/sup 2/, chemicals which interfere with repair of ultraviolet-induced pre-mutational lesions can be shown to enhance significantly the frequency of mutations to streptomycin resistance. This phenomenon is termed mutational synergism. We have attempted to apply the procedure for securing data for mutational synergism between ultraviolet (uv) radiation and a number of antimalarial drugs including quinine hydrochloride (50 ..mu..g/ml), quinine hydrobromide (50 ..mu..g/ml), primaquine diphosphate (50 ..mu..g/ml), chloroquine (50..mu..g/ml) and quinacrine dihydrochloride (25 ..mu..g/ml). All drugs tested give synergistic effects with uv light. The synergistic activity ranges from 3- to 35-fold. Quinine and quinacrine dihydrochloride have been found to be much more efficient enhancers of the mutagenic effect of uv than caffeine. In general, we have found that the expression of synergistic action occurs at a concentration well below the minimum inhibitory concentration (MIC) with the drugs tested. The implication of these observations in the establishment of a screening method for the evaluation of the mutagenicity of DNA repair inhibitors is discussed.

  4. Feasibility of testing DNA repair inhibitors for mutagenicity by a simple method

    Energy Technology Data Exchange (ETDEWEB)

    Sideropoulos, A S; Specht, S M; Jones, M T [Duquesne Univ., Pittsburgh, PA (USA). Dept. of Biological Sciences

    1980-04-01

    A simple screening methodology for the determination of mutagenicity of DNA repair inhibitors has been tested in this laboratory. Radiation-resistant E. coli B/r and WP2 hcr/sup +/ and hcr/sup -/ are suitable strains for mutagenicity testing. In these strains irradiated with 40-60 ergs/mm/sup 2/, chemicals which interfere with repair of ultraviolet-induced pre-mutational lesions can be shown to enhance significantly the frequency of mutations to streptomycin resistance. This phenomenon is termed 'mutational synergism' (18,20). We have attempted to apply the procedure for securing data for 'mutational synergism' between ultraviolet (UV) radiation and a number of antimalarial drugs including quinine hydrochloride (50 ..mu..g/ml), quinine hydrobromide (50 ..mu..g/ml), primaquine diphosphate (50 ..mu..g/ml), chloroquine (50 ..mu..g/ml), quinine (50 ..mu..g/ml) and quinacrine dihydrochloride (25 ..mu..g/ml). All drugs tested give synergistic effects with UV light. The synergistic activity ranges from 3- to 35-fold. Quinine and quinacrine dihydrochloride have been found to be much more efficient enhancers of the mutagenic effect of UV than caffeine. In general, we have found that the expression of synergistic action occurs at a concentration well below the minimum inhibitory concentration (MIC) with the drugs tested. The implication of these observations in the establishment of a screening method for the evaluation of the mutagenicity of DNA repair inhibitors is discussed.

  5. Increasing the realism of a laparoscopic box trainer: a simple, inexpensive method.

    Science.gov (United States)

    Hull, Louise; Kassab, Eva; Arora, Sonal; Kneebone, Roger

    2010-01-01

    Simulation-based training in medical education is increasing. Realism is an integral element of creating an engaging, effective training environment. Although physical trainers offer a low-cost alternative to expensive virtual reality (VR) simulators, many lack in realism. The aim of this research was to enhance the realism of a laparoscopic box trainer by using a simple, inexpensive method. Digital images of the abdominal cavity were captured from a VR simulator. The images were printed onto a laminated card that lined the bottom and sides of the box-trainer cavity. The standard black neoprene material that encloses the abdominal cavity was replaced with a skin-colored silicon model. The realism of the modified box trainer was assessed by surgeons, using quantitative and qualitative methodologies. Results suggest that the modified box trainer was more realistic than a standard box trainer alone. Incorporating this technique in the training of laparoscopic skills is an inexpensive means of emulating surgical reality that may enhance the engagement of the learner in simulation.

  6. Simple hybrid method for fine microaneurysm detection from non-dilated diabetic retinopathy retinal images.

    Science.gov (United States)

    Sopharak, Akara; Uyyanonvara, Bunyarit; Barman, Sarah

    2013-01-01

    Microaneurysms detection is an important task in computer aided diagnosis of diabetic retinopathy. Microaneurysms are the first clinical sign of diabetic retinopathy, a major cause of vision loss in diabetic patients. Early microaneurysm detection can help reduce the incidence of blindness. Automatic detection of microaneurysms is still an open problem due to their tiny sizes, low contrast and also similarity with blood vessels. It is particularly very difficult to detect fine microaneurysms, especially from non-dilated pupils and that is the goal of this paper. Simple yet effective methods are used. They are coarse segmentation using mathematic morphology and fine segmentation using naive Bayes classifier. A total of 18 microaneurysms features are proposed in this paper and they are extracted for naive Bayes classifier. The detected microaneurysms are validated by comparing at pixel level with ophthalmologists' hand-drawn ground-truth. The sensitivity, specificity, precision and accuracy are 85.68, 99.99, 83.34 and 99.99%, respectively. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. A simple and novel method for retrieval of Pasteurellaceae from swab samples collected in the field

    DEFF Research Database (Denmark)

    Hansen, Mie J; Bertelsen, Mads F; Dietz, Rune

    2013-01-01

    and stored at -20°C. As a control study, 15 samples were collected from the oral cavity of a captive brown bear. One was immediately plated, while the remaining 12 swabs were stored at -20°C for 7 days and multiples of 30 days up to 330 days prior to plating. Two samples were stored without the medium for 7......Traditionally it has been difficult or impossible to collect and preserve bacterial samples of especially fastidious bacteria in mixed primary cultures, unless the samples could be transported to a laboratory within approximately 24 h. Therefore, a simple novel method for preserving swab samples...... until bacterial isolation can be completed in the laboratory was developed and evaluated. Pasteurellaceae bacteria were used as a representative for fastidious bacteria. A 7.5% glucose serum medium was used as freeze medium. Swab samples were soaked in the medium a maximum of 2 h after collection...

  8. A simple finite element method for boundary value problems with a Riemann–Liouville derivative

    KAUST Repository

    Jin, Bangti

    2016-02-01

    © 2015 Elsevier B.V. All rights reserved. We consider a boundary value problem involving a Riemann-Liouville fractional derivative of order α∈(3/2,2) on the unit interval (0,1). The standard Galerkin finite element approximation converges slowly due to the presence of singularity term xα-1 in the solution representation. In this work, we develop a simple technique, by transforming it into a second-order two-point boundary value problem with nonlocal low order terms, whose solution can reconstruct directly the solution to the original problem. The stability of the variational formulation, and the optimal regularity pickup of the solution are analyzed. A novel Galerkin finite element method with piecewise linear or quadratic finite elements is developed, and L2(D) error estimates are provided. The approach is then applied to the corresponding fractional Sturm-Liouville problem, and error estimates of the eigenvalue approximations are given. Extensive numerical results fully confirm our theoretical study.

  9. A simple method for tuning the glass transition process in inorganic phosphate glasses

    Science.gov (United States)

    Fulchiron, René; Belyamani, Imane; Otaigbe, Joshua U.; Bounor-Legaré, Véronique

    2015-02-01

    The physical modification of glass transition temperature (Tg) and properties of materials via blending is a common practice in industry and academia and has a large economic advantage. In this context, simple production of hitherto unattainable new inorganic glass blends from already existing glass compositions via blending raises much hope with the potential to provide new glasses with new and improved properties, that cannot be achieved with classical glass synthesis, for a plethora of applications such as computers screens, glass-to-metal seals, and storage materials for nuclear wastes. Here, we demonstrate that blends of the specific glass compositions studied are miscible in all proportions, an unreported phenomenon in hard condensed matter like glass. Interestingly, excellent agreement was found between the obtained data and calculated Tgs from theoretical equations (Supplementary information) for predicting the composition dependence of Tg for miscible blends with weak but significant specific interactions between the blend components. That this blending method is at present not applied to inorganic glasses reflects the fact that water and chemically resistant phosphate glasses with relatively low Tgs have become available only recently.

  10. Arbitrarily primed PCR- A rapid and simple method for typing of leptospiral serovars

    Directory of Open Access Journals (Sweden)

    Ramadass P

    2002-01-01

    Full Text Available PURPOSE: To investigate the use of arbitrarily primed polymerase chain reaction (AP-PCR for typing of leptospiral serovars. METHODS: AP-PCR was adopted for identification of laboratory strains of leptospires and leptospiral cultures at serovar level. A primer of 12 bp was used for amplifying DNA of 13 laboratory strains of leptospires as well as culture pellets of leptospires. RESULTS: Each serovar produced distinct DNA fingerprint which was characteristic for each serovar. These patterns were used for typing of 81 serum culture samples obtained from human leptospiral cases. Of these samples, 39 could be typed based on AP-PCR fingerprints belonging to serovars autumnalis, pomona, canicola, javanica, icterohaemorrhagiae, patoc and pyrogenes. These results were confirmed by RAPD fingerprinting of the DNA samples of the respective leptospiral serovars after culturing -FNx01them in EMJH media. One of the important findings of this work was that straight culture sample could be used for AP-PCR assay, without purification of DNA. By having more number of AP-PCR reference fingerprints, more serovars could be typed. CONCLUSIONS: AP-PCR technique provides great potential for simple and rapid identification of leptospires at serovar level, which could be useful in molecular epidemiological studies of leptospirosis.

  11. Detecting surface runoff location in a small catchment using distributed and simple observation method

    Science.gov (United States)

    Dehotin, Judicaël; Breil, Pascal; Braud, Isabelle; de Lavenne, Alban; Lagouy, Mickaël; Sarrazin, Benoît

    2015-06-01

    Surface runoff is one of the hydrological processes involved in floods, pollution transfer, soil erosion and mudslide. Many models allow the simulation and the mapping of surface runoff and erosion hazards. Field observations of this hydrological process are not common although they are crucial to evaluate surface runoff models and to investigate or assess different kinds of hazards linked to this process. In this study, a simple field monitoring network is implemented to assess the relevance of a surface runoff susceptibility mapping method. The network is based on spatially distributed observations (nine different locations in the catchment) of soil water content and rainfall events. These data are analyzed to determine if surface runoff occurs. Two surface runoff mechanisms are considered: surface runoff by saturation of the soil surface horizon and surface runoff by infiltration excess (also called hortonian runoff). The monitoring strategy includes continuous records of soil surface water content and rainfall with a 5 min time step. Soil infiltration capacity time series are calculated using field soil water content and in situ measurements of soil hydraulic conductivity. Comparison of soil infiltration capacity and rainfall intensity time series allows detecting the occurrence of surface runoff by infiltration-excess. Comparison of surface soil water content with saturated water content values allows detecting the occurrence of surface runoff by saturation of the soil surface horizon. Automatic records were complemented with direct field observations of surface runoff in the experimental catchment after each significant rainfall event. The presented observation method allows the identification of fast and short-lived surface runoff processes at a small spatial and temporal resolution in natural conditions. The results also highlight the relationship between surface runoff and factors usually integrated in surface runoff mapping such as topography, rainfall

  12. A Simple and Reproducible Method to Prepare Membrane Samples from Freshly Isolated Rat Brain Microvessels.

    Science.gov (United States)

    Brzica, Hrvoje; Abdullahi, Wazir; Reilly, Bianca G; Ronaldson, Patrick T

    2018-05-07

    The blood-brain barrier (BBB) is a dynamic barrier tissue that responds to various pathophysiological and pharmacological stimuli. Such changes resulting from these stimuli can greatly modulate drug delivery to the brain and, by extension, cause considerable challenges in the treatment of central nervous system (CNS) diseases. Many BBB changes that affect pharmacotherapy, involve proteins that are localized and expressed at the level of endothelial cells. Indeed, such knowledge on BBB physiology in health and disease has sparked considerable interest in the study of these membrane proteins. From a basic science research standpoint, this implies a requirement for a simple but robust and reproducible method for isolation of microvessels from brain tissue harvested from experimental animals. In order to prepare membrane samples from freshly isolated microvessels, it is essential that sample preparations be enriched in endothelial cells but limited in the presence of other cell types of the neurovascular unit (i.e., astrocytes, microglia, neurons, pericytes). An added benefit is the ability to prepare samples from individual animals in order to capture the true variability of protein expression in an experimental population. In this manuscript, details regarding a method that is utilized for isolation of rat brain microvessels and preparation of membrane samples are provided. Microvessel enrichment, from samples derived, is achieved by using four centrifugation steps where dextran is included in the sample buffer. This protocol can easily be adapted by other laboratories for their own specific applications. Samples generated from this protocol have been shown to yield robust experimental data from protein analysis experiments that can greatly aid the understanding of BBB responses to physiological, pathophysiological, and pharmacological stimuli.

  13. A simple phenotypic method for screening of MCR-1-mediated colistin resistance.

    Science.gov (United States)

    Coppi, M; Cannatelli, A; Antonelli, A; Baccani, I; Di Pilato, V; Sennati, S; Giani, T; Rossolini, G M

    2018-02-01

    To evaluate a novel method, the colistin-MAC test, for phenotypic screening of acquired colistin resistance mediated by transferable mcr-1 resistance determinants, based on colistin MIC reduction in the presence of dipicolinic acid (DPA). The colistin-MAC test consists in a broth microdilution method, in which colistin MIC is tested in the absence or presence of DPA (900 μg/mL). Overall, 74 colistin-resistant strains of Enterobacteriaceae (65 Escherichia coli and nine other species), including 61 strains carrying mcr-1-like genes and 13 strains negative for mcr genes, were evaluated with the colistin-MAC test. The presence of mcr-1-like and mcr-2-like genes was assessed by real-time PCR and end-point PCR. For 20 strains, whole-genome sequencing data were also available. A ≥8-fold reduction of colistin MIC in the presence of DPA was observed with 59 mcr-1-positive strains, including 53 E. coli of clinical origin, three E. coli transconjugants carrying MCR-1-encoding plasmids, one Enterobacter cloacae complex and two Citrobacter spp. Colistin MICs were unchanged, increased or at most reduced by twofold with the 13 mcr-negative colistin-resistant strains (nine E. coli and four Klebsiella pneumoniae), but also with two mcr-1-like-positive K. pneumoniae strains. The colistin-MAC test could be a simple phenotypic test for presumptive identification of mcr-1-positive strains among isolates of colistin-resistant E. coli, based on a ≥8-fold reduction of colistin MIC in the presence of DPA. Evaluation of the test with a larger number of strains, species and mcr-type resistance determinants would be of interest. Copyright © 2017 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  14. A simple method for combining genetic mapping data from multiple crosses and experimental designs.

    Directory of Open Access Journals (Sweden)

    Jeremy L Peirce

    Full Text Available BACKGROUND: Over the past decade many linkage studies have defined chromosomal intervals containing polymorphisms that modulate a variety of traits. Many phenotypes are now associated with enough mapping data that meta-analysis could help refine locations of known QTLs and detect many novel QTLs. METHODOLOGY/PRINCIPAL FINDINGS: We describe a simple approach to combining QTL mapping results for multiple studies and demonstrate its utility using two hippocampus weight loci. Using data taken from two populations, a recombinant inbred strain set and an advanced intercross population we demonstrate considerable improvements in significance and resolution for both loci. 1-LOD support intervals were improved 51% for Hipp1a and 37% for Hipp9a. We first generate locus-wise permuted P-values for association with the phenotype from multiple maps, which can be done using a permutation method appropriate to each population. These results are then assigned to defined physical positions by interpolation between markers with known physical and genetic positions. We then use Fisher's combination test to combine position-by-position probabilities among experiments. Finally, we calculate genome-wide combined P-values by generating locus-specific P-values for each permuted map for each experiment. These permuted maps are then sampled with replacement and combined. The distribution of best locus-specific P-values for each combined map is the null distribution of genome-wide adjusted P-values. CONCLUSIONS/SIGNIFICANCE: Our approach is applicable to a wide variety of segregating and non-segregating mapping populations, facilitates rapid refinement of physical QTL position, is complementary to other QTL fine mapping methods, and provides an appropriate genome-wide criterion of significance for combined mapping results.

  15. A SIMPLE FLUORESCENT LABELING METHOD FOR STUDIES OF PROTEIN OXIDATION, PROTEIN MODIFICATION, AND PROTEOLYSIS

    Science.gov (United States)

    Pickering, Andrew. M.; Davies, Kelvin. J. A.

    2014-01-01

    Proteins are sensitive to oxidation, and oxidized proteins are excellent substrates for degradation by proteolytic enzymes such as the Proteasome and the mitochondrial Lon protease. Protein labeling is required for studies of protein turnover. Unfortunately, most labeling techniques involve 3H or 14C methylation which is expensive, exposes researchers to radioactivity, generates large amounts of radioactive waste, and allows only single-point assays because samples require acid-precipitation. Alternative labeling methods, have largely proven unsuitable, either because the probe itself is modified by the oxidant(s) being studied, or because the alternative labeling techniques are too complex or too costly for routine use. What is needed is a simple, quick, and cheap labeling technique that uses a non-radioactive marker, that binds strongly to proteins, is resistant to oxidative modification, and emits a strong signal. We have devised a new reductive method for labeling free carboxyl groups of proteins with the small fluorophore 7-amino-4-methycoumarin (AMC). When bound to target proteins, AMC fluoresces very weakly but when AMC is released by proteinases, proteases, or peptidases, it fluoresces strongly. Thus, without acid-precipitation, the proteolysis of any target protein can be studied continuously, in multiwell plates. In direct comparisons, 3H-labeled proteins and AMC-labeled proteins exhibited essentially identical degradation patterns during incubation with trypsin, cell extracts, and purified proteasome. AMC-labeled proteins are well-suited to study increased proteolytic susceptibility following protein modification, since the AMC-protein bond is resistant to oxidizing agents such as hydrogen peroxide and peroxynitrite, and is stable over time and to extremes of pH, temperature (even boiling), freeze-thawing, mercaptoethanol, and methanol. PMID:21988844

  16. A simple and reliable method reducing sulfate to sulfide for multiple sulfur isotope analysis.

    Science.gov (United States)

    Geng, Lei; Savarino, Joel; Savarino, Clara A; Caillon, Nicolas; Cartigny, Pierre; Hattori, Shohei; Ishino, Sakiko; Yoshida, Naohiro

    2018-02-28

    Precise analysis of four sulfur isotopes of sulfate in geological and environmental samples provides the means to extract unique information in wide geological contexts. Reduction of sulfate to sulfide is the first step to access such information. The conventional reduction method suffers from a cumbersome distillation system, long reaction time and large volume of the reducing solution. We present a new and simple method enabling the process of multiple samples at one time with a much reduced volume of reducing solution. One mL of reducing solution made of HI and NaH 2 PO 2 was added to a septum glass tube with dry sulfate. The tube was heated at 124°C and the produced H 2 S was purged with inert gas (He or N 2 ) through gas-washing tubes and then collected by NaOH solution. The collected H 2 S was converted into Ag 2 S by adding AgNO 3 solution and the co-precipitated Ag 2 O was removed by adding a few drops of concentrated HNO 3 . Within 2-3 h, a 100% yield was observed for samples with 0.2-2.5 μmol Na 2 SO 4 . The reduction rate was much slower for BaSO 4 and a complete reduction was not observed. International sulfur reference materials, NBS-127, SO-5 and SO-6, were processed with this method, and the measured against accepted δ 34 S values yielded a linear regression line which had a slope of 0.99 ± 0.01 and a R 2 value of 0.998. The new methodology is easy to handle and allows us to process multiple samples at a time. It has also demonstrated good reproducibility in terms of H 2 S yield and for further isotope analysis. It is thus a good alternative to the conventional manual method, especially when processing samples with limited amount of sulfate available. © 2017 The Authors. Rapid Communications in Mass Spectrometry Pubished by John Wiley & Sons Ltd.

  17. Simple and effective methods of freezing capercaillie (Tetrao urogallus L. semen.

    Directory of Open Access Journals (Sweden)

    Artur Kowalczyk

    Full Text Available A continuous decline in the number and range of capercaillie (Tetrao urogallus L. in many European countries can be observed, mostly due to habitat destruction by human activity, unecological forestry management, and increased density of natural predators. Ex situ in vitro gene banks provide a unique opportunity to preserve the genetic material for future generations. Simple and effective cryopreservation methods for capercaillie semen are discussed. Semen was collected from seven males kept in the Capercaillie Breeding Centre at Forestry Wisła in Poland. Within five minutes after collection, ejaculates were diluted with EK diluent, then divided into two parts, and subjected to two freezing procedures: in pellets and in straws. In fresh semen, ejaculate clearness, viscosity, color and volume, as well as sperm concentration, motility and morphology, were evaluated, while in frozen-thawed semen only motility and morphology of sperm were determined. Fertilizing ability of thawed semen was examined for samples frozen in straws. Significant (P<0.05 differences between individual males were found in relation to the majority of fresh semen traits: ejaculate volume averaged 102.1 µL (varying from 49.0 to 205.0; average sperm concentration was 632.5 x 10⁶ mL⁻¹ (178.8-1257.1; percentage of live normal cells varied from 39.2 to 70.3% (58.7% on an average; percentage of motile cells ranged from 76.0 to 85.7% and motility parameters were male dependent, as well. Both cryopreservation methods had a negative effect on morphology and motility of frozen-thawed semen; however, the straw method yielded 60.7% and the pellet method 42.5% of live cells in total in thawed semen (P<0.05, while the number of live normal (intact cells was similar (22.4 and 22.2%, respectively. Egg fertility varied between 77.8 and 91.7% (average 84.4%. Both freezing procedures seem to be effective in obtaining acceptable viability and high fertilizing potency of thawed sperm and

  18. Cumulative environmental effects. Summary

    International Nuclear Information System (INIS)

    2012-01-01

    This report presents a compilation of knowledge about the state of the environment and human activity in the Norwegian part of the North Sea and Skagerrak. The report gives an overview of pressures and impacts on the environment from normal activity and in the event of accidents. This is used to assess the cumulative environmental effects, which factors have most impact and where the impacts are greatest, and to indicate which problems are expected to be most serious in the future. The report is intended to provide relevant information that can be used in the management of the marine area in the future. It also provides input for the identification of environmental targets and management measures for the North Sea and Skagerrak.(Author)

  19. Cumulative environmental effects. Summary

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-07-01

    This report presents a compilation of knowledge about the state of the environment and human activity in the Norwegian part of the North Sea and Skagerrak. The report gives an overview of pressures and impacts on the environment from normal activity and in the event of accidents. This is used to assess the cumulative environmental effects, which factors have most impact and where the impacts are greatest, and to indicate which problems are expected to be most serious in the future. The report is intended to provide relevant information that can be used in the management of the marine area in the future. It also provides input for the identification of environmental targets and management measures for the North Sea and Skagerrak.(Author)

  20. A Simple Analytical Method Using HPLC with Fluorescence Detection to Determine Selected Polycyclic Aromatic Compounds in Filter Samples

    International Nuclear Information System (INIS)

    Garcia, S.; Perez, R. M.

    2014-01-01

    A study on the comparison and evaluation of a miniaturized extraction method for the determination of selected PACs in sample filters is presented. The main objective was the optimization and development of simple, rapid and low cost methods, minimizing the use of extracting solvent volume. The work also includes a study on the intermediate precision. (Author)

  1. A Convergence Result for the Euler-Maruyama Method for a Simple Stochastic Differential Equation with Discontinuous Drift

    DEFF Research Database (Denmark)

    Simonsen, Maria; Schiøler, Henrik; Leth, John-Josef

    2014-01-01

    The Euler-Maruyama method is applied to a simple stochastic differential equation (SDE) with discontinuous drift. Convergence aspects are investigated in the case, where the Euler-Maruyama method is simulated in dyadic points. A strong rate of convergence is presented for the numerical simulations...

  2. A fast and simple GC MS method for lignan profiling in Anthriscus sylvestris and biosynthetically related plant species

    NARCIS (Netherlands)

    Koulman, A; Bos, R; Medarde, M; Pras, N; Quax, WJ

    2001-01-01

    A new GC-MS method for monitoring lignans was developed to study the variation in plants and elucidate the biosynthetic steps. A simple and fast extraction procedure for lyophilised plant material was developed, giving a lignan-rich extract. A GC-MS method was set up using an apolar WCOT fused

  3. A Simple Method to Determine the "R" or "S" Configuration of Molecules with an Axis of Chirality

    Science.gov (United States)

    Wang, Cunde; Wu, Weiming

    2011-01-01

    A simple method for the "R" or "S" designation of molecules with an axis of chirality is described. The method involves projection of the substituents along the chiral axis, utilizes the Cahn-Ingold-Prelog sequence rules in assigning priority to the substituents, is easy to use, and has broad applicability. (Contains 5 figures.)

  4. Simple method for quantification of gadolinium magnetic resonance imaging contrast agents using ESR spectroscopy.

    Science.gov (United States)

    Takeshita, Keizo; Kinoshita, Shota; Okazaki, Shoko

    2012-01-01

    To develop an estimation method of gadolinium magnetic resonance imaging (MRI) contrast agents, the effect of concentration of Gd compounds on the ESR spectrum of nitroxyl radical was examined. A solution of either 4-oxo-2,2,6,6-tetramethylpiperidine-N-oxyl (TEMPONE) or 4-hydroxy-2,2,6,6-tetramethylpiperidine-N-oxyl (TEMPOL) was mixed with a solution of Gd compound and the ESR spectrum was recorded. Increased concentration of gadolinium-diethylenetriamine pentaacetic acid chelate (Gd-DTPA), an MRI contrast agent, increased the peak-to-peak line widths of ESR spectra of the nitroxyl radicals, in accordance with a decrease of their signal heights. A linear relationship was observed between concentration of Gd-DTPA and line width of ESR signal, up to approximately 50 mmol/L Gd-DTPA, with a high correlation coefficient. Response of TEMPONE was 1.4-times higher than that of TEMPOL as evaluated from the slopes of the lines. The response was slightly different among Gd compounds; the slopes of calibration curves for acua[N,N-bis[2-[(carboxymethyl)[(methylcarbamoyl)methyl]amino]ethyl]glycinato(3-)]gadolinium hydrate (Gd-DTPA-BMA) (6.22 μT·L/mmol) and gadolinium-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid chelate (Gd-DOTA) (6.62 μT·L/mmol) were steeper than the slope for Gd-DTPA (5.45 μT·L/mmol), whereas the slope for gadolinium chloride (4.94 μT·L/mmol) was less steep than that for Gd-DTPA. This method is simple to apply. The results indicate that this method is useful for rough estimation of the concentration of Gd contrast agents if calibration is carried out with each standard compound. It was also found that the plot of the reciprocal square root of signal height against concentrations of contrast agents could be useful for the estimation if a constant volume of sample solution is taken and measured at the same position in the ESR cavity every time.

  5. Standardization and validation of a novel and simple method to assess lumbar dural sac size

    International Nuclear Information System (INIS)

    Daniels, M.L.A.; Lowe, J.R.; Roy, P.; Patrone, M.V.; Conyers, J.M.; Fine, J.P.; Knowles, M.R.; Birchard, K.R.

    2015-01-01

    Aim: To develop and validate a simple, reproducible method to assess dural sac size using standard imaging technology. Materials and methods: This study was institutional review board-approved. Two readers, blinded to the diagnoses, measured anterior–posterior (AP) and transverse (TR) dural sac diameter (DSD), and AP vertebral body diameter (VBD) of the lumbar vertebrae using MRI images from 53 control patients with pre-existing MRI examinations, 19 prospectively MRI-imaged healthy controls, and 24 patients with Marfan syndrome with prior MRI or CT lumbar spine imaging. Statistical analysis utilized linear and logistic regression, Pearson correlation, and receiver operating characteristic (ROC) curves. Results: AP-DSD and TR-DSD measurements were reproducible between two readers (r = 0.91 and 0.87, respectively). DSD (L1–L5) was not different between male and female controls in the AP or TR plane (p = 0.43; p = 0.40, respectively), and did not vary by age (p = 0.62; p = 0.25) or height (p = 0.64; p = 0.32). AP-VBD was greater in males versus females (p = 1.5 × 10 −8 ), resulting in a smaller dural sac ratio (DSR) (DSD/VBD) in males (p = 5.8 × 10 −6 ). Marfan patients had larger AP-DSDs and TR-DSDs than controls (p = 5.9 × 10 −9 ; p = 6.5 × 10 −9 , respectively). Compared to DSR, AP-DSD and TR-DSD better discriminate Marfan from control subjects based on area under the curve (AUC) values from unadjusted ROCs (AP-DSD p < 0.01; TR-DSD p = 0.04). Conclusion: Individual vertebrae and L1–L5 (average) AP-DSD and TR-DSD measurements are simple, reliable, and reproducible for quantitating dural sac size without needing to control for gender, age, or height. - Highlights: • DSD (L1-L5) does not differ in the AP or TR plane by gender, height, or age. • AP- and TR-DSD measures correlate well between readers with different experience. • Height is positively correlated to AP-VBD in both males and females. • Varying

  6. A rapid and simple separation method of Tc-99 in water samples

    International Nuclear Information System (INIS)

    Uchida, Shigeo; Tagami, Keiko

    1999-01-01

    Technetium-99 ( 99 Tc) is one of the important elements on safety evaluation of reprocessing plant and waste disposal plant, because it is a long half-life nuclide and large fission yield (about 6%) from 235 U and 239 Pu. We studied in this work a rapid and simple separation method of 99 Tc in water samples by ICP-MS. Tc in 2 litre of inland water or 1.5 litre of sea water sample solutions was condensed and separated by mini-column resin (TEVA·Spec resin) (Eichrom Co., Ltd.). The experimental results showed the best conditions as followed that 1) after controlling 0.1M nitric acid sample solution, passed it through the column, 2) then the inhibitory elements such as Ru are removed by 40 ml of 2M nitric acid solution, and 3) Tc was recovered by 4 ml of 8M nitric acid solution. 95% or more recovery of Tc was obtained. 100% Ru, an inhibited element of ICP-MS, was removed. The elute obtained from 4 ml of 8M nitric acid solution was diluted ten times with pure water and 99 Tc was measured by ICP-MS. The limit of detection of 2 litre inland water and 1.5 litre sea water were 3 mBql -1 and 4 mBql -1 , respectively. The organic compounds were not removed before running to column, because the concentration of organic compounds was not so large. When large amounts of them are contained, they should be removed. If suspended materials absorb Tc, Tc should be changed to TcO 4 - . (S.Y.)

  7. A simple method for serving Web hypermaps with dynamic database drill-down

    Directory of Open Access Journals (Sweden)

    Carson Ewart R

    2002-08-01

    Full Text Available Abstract Background HealthCyberMap http://healthcybermap.semanticweb.org aims at mapping parts of health information cyberspace in novel ways to deliver a semantically superior user experience. This is achieved through "intelligent" categorisation and interactive hypermedia visualisation of health resources using metadata, clinical codes and GIS. HealthCyberMap is an ArcView 3.1 project. WebView, the Internet extension to ArcView, publishes HealthCyberMap ArcView Views as Web client-side imagemaps. The basic WebView set-up does not support any GIS database connection, and published Web maps become disconnected from the original project. A dedicated Internet map server would be the best way to serve HealthCyberMap database-driven interactive Web maps, but is an expensive and complex solution to acquire, run and maintain. This paper describes HealthCyberMap simple, low-cost method for "patching" WebView to serve hypermaps with dynamic database drill-down functionality on the Web. Results The proposed solution is currently used for publishing HealthCyberMap GIS-generated navigational information maps on the Web while maintaining their links with the underlying resource metadata base. Conclusion The authors believe their map serving approach as adopted in HealthCyberMap has been very successful, especially in cases when only map attribute data change without a corresponding effect on map appearance. It should be also possible to use the same solution to publish other interactive GIS-driven maps on the Web, e.g., maps of real world health problems.

  8. Investigation of toxigenic potential of fungal species by the use of simple screening method

    Directory of Open Access Journals (Sweden)

    Bočarov-Stančić Aleksandra S.

    2009-01-01

    Full Text Available Potential for the biosynthesis of aflatoxin B1 (AFLB1, ochratoxin A (OTA, diacetoxyscirpenol (DAS, T-2 toxin (T2, and zearalenone (ZON was investigated in different fungal species belonging to the genera: Aspergillus, Fusarium and Penicillium. The majority of investigated isolates originated from cereal grains, crushed oil soybean seed and fodder mixtures. The simple screening method developed by Filtenborg et al. (1983 was applied with few modifications concerning the type of the medium and cultivation temperature. In order to optimise the biosynthetic conditions for different mycotoxins, the following control cultures, known as mycotin producers were used: OTA - A. ochraceus CBS 108.08, DAS - F. semitectum (SL-B i SL-C, T2 - F. sporotrichioides (ITM-391, M-1-1, R-2301 and ZON - F. graminearum (GZ-LES. The fungi were cultivated on the standard medium (YESA - 2% yeast extract, 15% sucrose and 2% agar, pH 6.5, three modifications of the basic medium (YESAZn - the standard medium supplemented with 0.23 mg/l ZnSO4 x 5 H2O; PPSA - the medium in which yeast extract was replaced with peptone-1; PPSAZn - the medium in which yeast extract was replaced with peptone-1 and supplemented with 0.23 mg/l ZnSO4 x 5 H2O, and the potato-dextrose agar (PDA. The earlier biosynthesis of tested mycotoxins was recorded under the following cultivation conditions of fungal species: AFLB1 - after 14 days on PDA at 27±1°C, OTA - after 10 days on YESA and YESAZn at 27±1°C, DAS - after 10 days on PPSA and PPSAZn at 27±1°C, T2 - after 7 days on PPSAZn and PPSA at room temperature (20-24°C, and ZON - after 1 week on YESA and YESAZn at room temperature (21-24°C.

  9. The concept and method of closed reduction and internal fixation: a new approach for the treatment of simple zygoma fractures.

    Science.gov (United States)

    Uda, Hirokazu; Kamochi, Hideaki; Sugawara, Yasushi; Sarukawa, Syunji; Sunaga, Ataru

    2013-11-01

    The authors have developed a new minimally invasive surgical procedure for simple zygoma fractures, a closed reduction and internal fixation method, that uses a cannulated cortical screw system. From 2007 to 2012, 42 selected patients with simple zygoma fractures without ocular problems or shear at the zygomatic frontal portion were treated with this method. The mean age of the patients was 33 years (range, 13 to 77 years). The authors achieved good repositioning, equivalent to results achieved with conventional procedures in all cases. No notable complication occurred except for minor infection in two cases. Mean operative time was 32 minutes (range, 19 to 58 minutes). Postoperative relapse was found only in the posterior direction (poperative time, less effect on soft tissue, maintenance of bone healing potential, and decreased postoperative pain and swelling. The authors concluded that this method has the potential to become a future surgical procedure for simple zygoma fractures. Therapeutic, IV.

  10. A simple and affordable membrane-feeding method for Aedes aegpyti and Anopheles minimus (Diptera: Culicidae).

    Science.gov (United States)

    Finlayson, Catherine; Saingamsook, Jassada; Somboon, Pradya

    2015-12-01

    This study developed an artificial feeding (AF) method to replace direct host feeding (DHF) for the maintenance of Aedes aegypti and Anopheles minimus mosquito colonies. The procedure can be adopted by all laboratories due to its simple and affordable materials and design. The apparatus consists of heparinized cow blood contained in a 5cm diameter glass petri dish with 5cm(2) Parafilm M (Bemis(®)) stretched thinly over the top, with a pre-heated bag of vegetable oil placed underneath to keep the blood warm. Both parts are contained within an insulated Styrofoam™ box with a hole in the lid for mosquitoes to access the membrane. Mosquitoes are fed by AF for 15min at a time. Feeding rate and fecundity of Ae. aegypti mosquitoes feeding on the AF device were compared to those feeding on a live rat (DHF(r)), and of Anopheles minimus mosquitoes feeding on the AF device compared to those feeding on a human arm (DHF(h)). Aedes aegypti mosquitoes fed by AF or DHF(r) had similar feeding rates (38.2±21.5% and 35.7±18.2%, respectively) and overall egg production (1.5% difference). Anopheles minimus mosquitoes fed by the AF method had a lower feeding rate (52.0±1.0% for AF compared to 70.7±20.2% for DHF(h)) and overall egg production (40% reduction compared to DHF(h)). However, the number of eggs produced by AF-fed mosquitoes (1808 eggs per 100 mosquitoes) was still sufficient for colony maintenance, and with increased feeding time both parameters are expected to increase. Reduced feeding rate and overall egg production was observed when Ae. aegypti mosquitoes were fed on blood refrigerated for over two weeks. In conclusion, an AF device has been developed which can replace DHF for Ae. aegypti and An. minimus colony maintenance when using blood refrigerated for a maximum of two weeks. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. A simple method of equine limb force vector analysis and its potential applications

    Directory of Open Access Journals (Sweden)

    Sarah Jane Hobbs

    2018-02-01

    Full Text Available Background Ground reaction forces (GRF measured during equine gait analysis are typically evaluated by analyzing discrete values obtained from continuous force-time data for the vertical, longitudinal and transverse GRF components. This paper describes a simple, temporo-spatial method of displaying and analyzing sagittal plane GRF vectors. In addition, the application of statistical parametric mapping (SPM is introduced to analyse differences between contra-lateral fore and hindlimb force-time curves throughout the stance phase. The overall aim of the study was to demonstrate alternative methods of evaluating functional (asymmetry within horses. Methods GRF and kinematic data were collected from 10 horses trotting over a series of four force plates (120 Hz. The kinematic data were used to determine clean hoof contacts. The stance phase of each hoof was determined using a 50 N threshold. Vertical and longitudinal GRF for each stance phase were plotted both as force-time curves and as force vector diagrams in which vectors originating at the centre of pressure on the force plate were drawn at intervals of 8.3 ms for the duration of stance. Visual evaluation was facilitated by overlay of the vector diagrams for different limbs. Summary vectors representing the magnitude (VecMag and direction (VecAng of the mean force over the entire stance phase were superimposed on the force vector diagram. Typical measurements extracted from the force-time curves (peak forces, impulses were compared with VecMag and VecAng using partial correlation (controlling for speed. Paired samples t-tests (left v. right diagonal pair comparison and high v. low vertical force diagonal pair comparison were performed on discrete and vector variables using traditional methods and Hotelling’s T2 tests on normalized stance phase data using SPM. Results Evidence from traditional statistical tests suggested that VecMag is more influenced by the vertical force and impulse, whereas

  12. A simple method of equine limb force vector analysis and its potential applications.

    Science.gov (United States)

    Hobbs, Sarah Jane; Robinson, Mark A; Clayton, Hilary M

    2018-01-01

    Ground reaction forces (GRF) measured during equine gait analysis are typically evaluated by analyzing discrete values obtained from continuous force-time data for the vertical, longitudinal and transverse GRF components. This paper describes a simple, temporo-spatial method of displaying and analyzing sagittal plane GRF vectors. In addition, the application of statistical parametric mapping (SPM) is introduced to analyse differences between contra-lateral fore and hindlimb force-time curves throughout the stance phase. The overall aim of the study was to demonstrate alternative methods of evaluating functional (a)symmetry within horses. GRF and kinematic data were collected from 10 horses trotting over a series of four force plates (120 Hz). The kinematic data were used to determine clean hoof contacts. The stance phase of each hoof was determined using a 50 N threshold. Vertical and longitudinal GRF for each stance phase were plotted both as force-time curves and as force vector diagrams in which vectors originating at the centre of pressure on the force plate were drawn at intervals of 8.3 ms for the duration of stance. Visual evaluation was facilitated by overlay of the vector diagrams for different limbs. Summary vectors representing the magnitude (VecMag) and direction (VecAng) of the mean force over the entire stance phase were superimposed on the force vector diagram. Typical measurements extracted from the force-time curves (peak forces, impulses) were compared with VecMag and VecAng using partial correlation (controlling for speed). Paired samples t -tests (left v. right diagonal pair comparison and high v. low vertical force diagonal pair comparison) were performed on discrete and vector variables using traditional methods and Hotelling's T 2 tests on normalized stance phase data using SPM. Evidence from traditional statistical tests suggested that VecMag is more influenced by the vertical force and impulse, whereas VecAng is more influenced by the

  13. A simple method to impose rotations and concentrated moments on ANC beams

    International Nuclear Information System (INIS)

    Romero, Ignacio; Arribas, Juan J.

    2009-01-01

    Recently introduced ANC beam elements furnish a simple formulation that allows to solve nonlinear problems of beams, including those with large displacements and strains, as well as complex nonlinear (inelastic) materials. The success and simplicity of these finite elements is mainly due to the fact that the only nodal degrees of freedom that they employ are displacements, and rotations are thus completely avoided. This in turn makes it very difficult to apply concentrated moments or to impose rotations at specific nodes of a finite element mesh. In this article, we present a simple enhancement to this beam formulation that allows to apply these two types of boundary conditions in a simple manner, making ANC beam elements more versatile for both multibody and structural applications

  14. Um método simples para o projeto ótimo de gráficos de X A simple method for optimal X-chart design

    Directory of Open Access Journals (Sweden)

    Eugenio K. Epprecht

    1998-12-01

    Full Text Available É desenvolvido um método simples e eficiente para a seleção de parâmetros (tamanho de amostra, intervalo de tempo entre amostras, e largura dos limites de controle para gráficos de para controle estatístico de processos, que fornece soluções ótimas em termos da relação entre a rapidez de detecção e os recursos alocados à inspeção. O método é superior a procedimentos baseados em propriedades estatísticas do gráfico (tais como o ARL e à adoção de valores empíricos gerais, e não apresenta as dificuldades de implementação dos métodos econômicos (economic design: não requer dados difíceis de obter ou estimar nem programas de computador para solução. Os resultados obtidos diferem de alguns resultados bem difundidos na literatura; mostra-se que os últimos são subótimos, por serem baseados em modelos que desconsideram aspectos importantes do problema. Uma contribuição adicional do método é o tratamento explícito e detalhado de restrições opcionais ao tamanho de amostra e/ou ao intervalo de tempo entre amostras. A simplicidade do método o torna viável para implementação em qualquer ambiente, e também apropriado para a sala de aula.A simple but efficient method has been developed for the design of -charts. The solutions provided are optimal in terms of the ratio between the number of items inspected per unit time and the detection speed (defined as the inverse of the average time to signal a shift in the mean. The method is superior to design procedures based exclusively on statistical properties of the chart (such as the ARL, and does not have the implementation drawbacks of economical design models. The results obtained differ from some results widely reported in the literature, which are shown to be sub-optimal as a consequence of their underlying model not considering some important aspects of the problem. An additional contribution of the method is the explicit treatment of optional constraints on the

  15. A computationally simple and robust method to detect determinism in a time series

    DEFF Research Database (Denmark)

    Lu, Sheng; Ju, Ki Hwan; Kanters, Jørgen K.

    2006-01-01

    We present a new, simple, and fast computational technique, termed the incremental slope (IS), that can accurately distinguish between deterministic from stochastic systems even when the variance of noise is as large or greater than the signal, and remains robust for time-varying signals. The IS ......We present a new, simple, and fast computational technique, termed the incremental slope (IS), that can accurately distinguish between deterministic from stochastic systems even when the variance of noise is as large or greater than the signal, and remains robust for time-varying signals...

  16. Chimpanzees (Pan troglodytes) and the question of cumulative culture: an experimental approach.

    Science.gov (United States)

    Marshall-Pescini, Sarah; Whiten, Andrew

    2008-07-01

    There is increasing evidence for cultural variations in behaviour among non-human species, but human societies additionally display elaborate cumulative cultural evolution, with successive generations building on earlier achievements. Evidence for cumulative culture in non-human species remains minimal and controversial. Relevant experiments are also lacking. Here we present a first experiment designed to examine chimpanzees' capacity for cumulative social learning. Eleven young chimpanzees were presented with a foraging device, which afforded both a relatively simple and a more complex tool-use technique for extracting honey. The more complex 'probing' technique incorporated the core actions of the simpler 'dipping' one and was also much more productive. In a baseline, exploration condition only two subjects discovered the dipping technique and a solitary instance of probing occurred. Demonstrations of dipping by a familiar human were followed by acquisition of this technique by the five subjects aged three years or above, whilst younger subjects showed a significant increase only in the elements of the dipping technique. By contrast, subsequent demonstrations of the probing task were not followed by acquisition of this more productive technique. Subjects stuck to their habitual dipping method despite an escalating series of demonstrations eventually exceeding 200. Supplementary tests showed this technique is within the capability of chimpanzees of this age. We therefore tentatively conclude that young chimpanzees exhibit a tendency to become 'stuck' on a technique they initially learn, inhibiting cumulative social learning and possibly constraining the species' capacity for cumulative cultural evolution.

  17. Simple Method for Assessing Spread of Flood Prone Areas under Historical and Future Rainfall in the Upper Citarum Watershed

    Directory of Open Access Journals (Sweden)

    Bambang Dwi Dasanto

    2014-06-01

    Full Text Available From 1931 to 2010 the flood frequency in Upper Citarum Watershed had increased sharply indicating the decline of the wateshed quality. With the change of climate, risk of the flood may get worse. This study aims to determine effective rainfall that caused flooding and to evaluate the impact of future rainfall changes on the flood prone areas. Effective rainfall which contributes to direct runoff (DRO and leads to flooding was determined using regression equation relating the DRO and cumulative rainfall of a number of consecutive days. Mapping the flood prone areas was developed using the GIS techniques. Results showed that the effective rainfall which caused flooding was the rainfall accumulation for four consecutive days before occurrence of peak of DRO. The percentage of accuracy between estimated and actual flood maps was about 76.9%. According to historical rainfall, the flood prone areas spreaded at right and left directions of the Upstream Citarum River. If this area experiences the climate change, the frequency and flood extents will increase. This study can only identify locations and possibility of flood occurrence but it cannot demonstrate widespread of flood inundation precisely. However, this simple approach can evaluate the flood frequency and intensity quite well.

  18. Setaria viridis floral-dip: A simple and rapid Agrobacterium-medicated transformation method

    Science.gov (United States)

    Setaria viridis was recently described as a new monocotyledonous model species for C4 photosynthesis research and genetic transformation. It has biological attributes (rapid life cycle, small genome, diploid, short stature and simple growth requirements) that make it suitable for use as a model plan...

  19. An Inexpensive and Simple Method to Demonstrate Soil Water and Nutrient Flow

    Science.gov (United States)

    Nichols, K. A.; Samson-Liebig, S.

    2011-01-01

    Soil quality, soil health, and soil sustainability are concepts that are being widely used but are difficult to define and illustrate, especially to a non-technical audience. The objectives of this manuscript were to develop simple and inexpensive methodologies to both qualitatively and quantitatively estimate water infiltration rates (IR),…

  20. A simple and effective method to encapsulate tobacco mesophyll protoplasts to maintain cell viability

    Directory of Open Access Journals (Sweden)

    Rong Lei

    2015-01-01

    • It is very convenient to change or collect the solution without mechanically disturbing the protoplasts. This simple and effective silica sol–gel/alginate two-step immobilization of protoplasts in Transwell has great potential for applications in genetic transformation, metabolite production, and migration assays.