WorldWideScience

Sample records for method publish x-ms-olk-forceinspectoropen

  1. Comparison of 7 Published LC-MS/MS Methods for the Simultaneous Measurement of Testosterone, Androstenedione, and Dehydroepiandrosterone in Serum

    DEFF Research Database (Denmark)

    Büttler, Rahel M; Martens, Frans; Fanelli, Flaminia

    2015-01-01

    , and dehydroepiandrosterone (DHEA). METHODS: We used 7 published LC-MS/MS methods to analyze in duplicate 55 random samples from both men and women. We performed Passing-Bablok regression analysis and calculated Pearson correlation coefficients to assess the agreement of the methods investigated with the median concentration...

  2. LC-MS (/MS) in clinical toxicology screening methods.

    Science.gov (United States)

    Viette, Véronique; Hochstrasser, Denis; Fathi, Marc

    2012-01-01

    Toxicological screening is the analysis of biological samples to detect and identify unknown compounds. The high selectivity and sensitivity of liquid chromatography (LC) coupled to mass spectrometry (MS) or tandem mass spectrometry (MS/MS) technology provide an attractive alternative to the current methods (LC-UV, GC/MS, etc.). For these reasons, an increasing number of applications are being published. This paper is a brief overview of LC-MS(/MS) screening methods developed for clinical toxicology in recent years. Various sample treatments, chromatographic separations and detection by mass spectrometry can be combined to obtain screening methods adapted to the constraints and needs of clinical toxicology laboratories. Currently the techniques are in the hands of specialists, mainly in academic institutions. However, the evolution in technology should allow application of these techniques as a tool in toxicology laboratories, thus allowing a more widespread exploitation of their potential.

  3. An improved method of sample preparation on AnchorChip targets for MALDI-MS and MS/MS and its application in the liver proteome project

    DEFF Research Database (Denmark)

    Zhang, Xumin; Shi, Liang; Shu, Shaokung

    2007-01-01

    An improved method for sample preparation for MALDI-MS and MS/MS using AnchorChip targets is presented. The method, termed the SMW method (sample, matrix wash), results in better sensitivity for peptide mass fingerprinting as well as for sequencing by MS/MS than previously published methods. The ...

  4. Quantitative analysis of unconjugated and total bisphenol A in human urine using solid-phase extraction and UPLC-MS/MS: method implementation, method qualification and troubleshooting.

    Science.gov (United States)

    Buscher, Brigitte; van de Lagemaat, Dick; Gries, Wolfgang; Beyer, Dieter; Markham, Dan A; Budinsky, Robert A; Dimond, Stephen S; Nath, Rajesh V; Snyder, Stephanie A; Hentges, Steven G

    2015-11-15

    The aim of the presented investigation was to document challenges encountered during implementation and qualification of a method for bisphenol A (BPA) analysis and to develop and discuss precautions taken to avoid and to monitor contamination with BPA during sample handling and analysis. Previously developed and published HPLC-MS/MS methods for the determination of unconjugated BPA (Markham et al. Journal of Analytical Toxicology, 34 (2010) 293-303) [17] and total BPA (Markham et al. Journal of Analytical Toxicology, 38 (2014) 194-203) [20] in human urine were combined and transferred into another laboratory. The initial method for unconjugated BPA was developed and evaluated in two independent laboratories simultaneously. The second method for total BPA was developed and evaluated in one of these laboratories to conserve resources. Accurate analysis of BPA at sub-ppb levels is a challenging task as BPA is a widely used material and is ubiquitous in the environment at trace concentrations. Propensity for contamination of biological samples with BPA is reported in the literature during sample collection, storage, and/or analysis. Contamination by trace levels of BPA is so pervasive that even with extraordinary care, it is difficult to completely exclude the introduction of BPA into biological samples and, consequently, contamination might have an impact on BPA biomonitoring data. The applied UPLC-MS/MS method was calibrated from 0.05 to 25ng/ml. The limit of quantification was 0.1ng/ml for unconjugated BPA and 0.2ng/ml for total BPA, respectively, in human urine. Finally, the method was applied to urine samples derived from 20 volunteers. Overall, BPA can be analyzed in human urine with acceptable recovery and repeatability if sufficient measures are taken to avoid contamination throughout the procedure from sample collection until UPLC-MS/MS analysis. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  5. Analysis of acrylamide by LC-MS/MS and GC-MS in processed Japanese foods.

    Science.gov (United States)

    Ono, H; Chuda, Y; Ohnishi-Kameyama, M; Yada, H; Ishizaka, M; Kobayashi, H; Yoshida, M

    2003-03-01

    Acrylamide concentrations in processed foods (63 samples covering 31 product types) from Japan were analysed by LC-MS/MS and GC-MS methods. The limit of detection and limit of quantification of acrylamide were 0.2 ng x ml(-1) (6 fmol) and 0.8 ng x ml(-1) (22 fmol), respectively, by LC-MS/MS, and those of 2,3-dibromopropionamide derived from acrylamide were 12 ng x ml(-1) (52 fmol) and 40 ng x ml(-1) (170 fmol), respectively, by GC-MS. Repeatability given as RSD was 1000 microg x kg(-1). The concentrations in non-whole potato-based snacks, rice crackers processed by grilling or frying, and candied sweet potatoes were lower compared with those in the potato crisps and the whole potato-based fried snacks. One of the whole potato-based fried snacks, however, showed low acrylamide concentration (instant precooked noodles and won-tons were <100 microg x kg(-1) with only one exception. Roasted barley grains for 'Mugi-cha' tea contained 200-600 microg x kg(-1) acrylamide.

  6. Development of data acquisition and processing software based on MS-Windows 3.X for safeguards

    International Nuclear Information System (INIS)

    Tan Yajun

    1996-01-01

    The development method of data acquisition and processing software based on MS-Windows 3.X for safeguards is presented. The paper describes the design methods of graphical user interface (GUI), multiwindow and multitask-based spectrum graph display, data acquisition and processing and the application of object-oriented programming (OOP). Using the package, an effective prototype design path can be found for MS-Windows-based software. The methods and programs have been applied in some safeguard non-destructive assay system

  7. Development and validation of a LC-MS/MS method for the determination of clebopride and its application to a pharmacokinetics study in healthy Chinese volunteers.

    Science.gov (United States)

    Tan, Zhirong; Ouyang, Dongsheng; Chen, Yao; Zhou, Gan; Cao, Shan; Wang, Yicheng; Peng, Xiujuan; Zhou, Honghao

    2010-08-01

    A sensitive and specific liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS/MS) method has been developed and validated for the identification and quantification of clebopride in human plasma using itopride as an internal standard. The method involves a simple liquid-liquid extraction. The analytes were separated by isocratic gradient elution on a CAPCELL MG-III C(18) (5 microm, 150 mm x 2.1 mm i.d.) column and analyzed in multiple reaction monitoring (MRM) mode with positive electrospray ionization (ESI) interface using the respective [M+H](+) ions, m/z 373.9-->m/z184.0 for clebopride, m/z 359.9-->m/z71.5 for itopride. The method was validated over the concentration range of 69.530-4450.0 pg/ml for clebopride. Within- and between-batch precision (RSD%) was all within 6.83% and accuracy ranged from -8.16 to 1.88%. The LLOQ was 69.530 pg/ml. The extraction recovery was on an average 77% for clebopride. The validated method was used to study the pharmacokinetics profile of clebopride in human plasma after oral administration of clebopride. Copyright 2010. Published by Elsevier B.V.

  8. Determination of Tinopal CBS-X in rice papers and rice noodles using HPLC with fluorescence detection and LC-MS/MS.

    Science.gov (United States)

    Ko, Kyung Yuk; Lee, Chae A; Choi, Jae Chon; Kim, Meehye

    2014-01-01

    To date there have been no reports of methods to determine Tinopal CBS-X. We developed a rapid and simple method to determine the Tinopal CBS-X content in rice noodles and rice papers using HPLC equipped with fluorescence detection. Heating the rice noodles and rice papers to 80°C after adding 75% methanol solution induced the release of Tinopal CBS-X from processed rice products. Tinopal CBS-X was separated using an isocratic mobile phase comprising 50% acetonitrile/water containing 0.4% tetrabutyl ammonium hydrogen sulphate at pH 8.0. The samples suspected to be positive by HPLC analysis were then confirmed by LC-MS/MS analysis. This study also investigated the Tinopal CBS-X content of three rice noodle products and two rice papers. The limits of quantification for rice papers and rice noodles were 1.58 and 1.51 µg kg(-1), respectively, and their correlation curves showed good linearity with r(2) ≥ 0.9997 and ≥ 0.9998, respectively. Moreover, rice papers had recoveries of 70.3-83.3% with precision ranging from 5.0% to 7.9%, whereas rice noodles had slightly lower recoveries of 63.4-78.7% and precisions of 8.5-11.5%. Only one rice noodle product contained Tinopal CBS-X, at around 2.1 mg kg(-1), whereas it was not detected in four other samples. Consequently, Tinopal CBS-X from rice noodles and rice papers can be successfully detected using the developed pre-treatment and ion-pairing HPLC system coupled with fluorescence detection.

  9. Development and Validation of a Novel LC-MS/MS Opioid Confirmation Assay: Evaluation of β-glucuronidase Enzymes and Sample Cleanup Methods.

    Science.gov (United States)

    Yang, He S; Wu, Alan H B; Lynch, Kara L

    2016-06-01

    With the rise in the use and misuse of prescription opioids, there is an increasing need for the confirmed identification of opioid analgesics in toxicology laboratories. The goals of this study were to (i) systematically evaluate the hydrolysis efficiency of four β-glucuronidase enzymes under optimized condition; (ii) evaluate compound recovery, matrix effects and precision of three protein precipitation plates and (iii) develop and validate a qualitative liquid-chromatography mass spectrometry (LC-MS/MS) assay to identify 13 opioids in urine. A recombinant β-glucuronidase exhibited the best overall hydrolysis efficiency for seven opioid glucuronide conjugates compared with β-glucuronidase from red abalone, Escherichia coli and Patella vulgata One of the protein precipitation plates tested exhibited overall better recovery of the opioids and lower ion suppression compared with the other two plates. An ESI positive mode LC-MS/MS assay for qualitative opioid analysis was developed and validated. Linearity, LOD, precision, matrix effect, recovery, carryover and interference of the method were evaluated. Sixty-two patient samples were analyzed by both a legacy GC-MS opioid method and the LC-MS/MS method, and 22 samples were analyzed by the LC-MS/MS and an LC-MS/MS reference method. The results of the comparisons showed good concordance. Overall, we described an efficient sample preparation procedure for a sensitive qualitative opioid confirmation assay in urine. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. A simple and effective method for detecting precipitated proteins in MALDI-TOF MS.

    Science.gov (United States)

    Oshikane, Hiroyuki; Watabe, Masahiko; Nakaki, Toshio

    2018-04-01

    MALDI-TOF MS has developed rapidly into an essential analytical tool for the life sciences. Cinnamic acid derivatives are generally employed in routine molecular weight determinations of intact proteins using MALDI-TOF MS. However, a protein of interest may precipitate when mixed with matrix solution, perhaps preventing MS detection. We herein provide a simple approach to enable the MS detection of such precipitated protein species by means of a "direct deposition method" -- loading the precipitant directly onto the sample plate. It is thus expected to improve routine MS analysis of intact proteins. Copyright © 2018. Published by Elsevier Inc.

  11. Observation of Intravascular Changes of Superabsorbent Polymer Microsphere (SAP-MS) with Monochromatic X-Ray Imaging

    International Nuclear Information System (INIS)

    Tanimoto, Daigo; Ito, Katsuyoshi; Yamamoto, Akira; Sone, Teruki; Kobatake, Makito; Tamada, Tsutomu; Umetani, Keiji

    2010-01-01

    This study was designed to evaluate the intravascular transformation behavior of superabsorbent polymer microsphere (SAP-MS) in vivo macroscopically by using monochromatic X-ray imaging and to quantitatively compare the expansion rate of SAP-MS among different kinds of mixtures. Fifteen rabbits were used for our study and transcatheter arterial embolization (TAE) was performed for their auricular arteries using monochromatic X-ray imaging. We used three kinds of SAP-MS (particle diameter 100-150 μm) mixture as embolic spherical particles: SAP-MS(H) absorbed with sodium meglumine ioxaglate (Hexabrix 320), SAP-MS(V) absorbed with isosmolar contrast medium (Visipaque 270), and SAP-MS(S) absorbed with 0.9% sodium saline. The initial volume of SAP-MS particles just after TAE and its final volume 10 minutes after TAE in the vessel were measured to calculate the expansion rate (ER) (n = 30). Intravascular behavior of SAP-MS particles was clearly observed in real time at monochromatic X-ray imaging. Averaged initial volumes of SAP-MS (H) (1.24 x 10 7 μm 3 ) were significantly smaller (p 7 μm 3 ) and SAP-MS (S) (5.85 x 10 7 μm 3 ). Averaged final volumes of SAP-MS (H) were significantly larger than averaged initial volumes (4.41 x 10 7 μm 3 vs. 1.24 x 10 7 μm 3 ; p < 0.0001, ER = 3.55). There were no significant difference between averaged final volumes and averaged initial volumes of SAP-MS (V) and SAP-MS (S). SAP-MS (H), which first travels distally, reaches to small arteries, and then expands to adapt to the vessel lumen, is an effective particle as an embolic agent, causing effective embolization.

  12. Method-MS. Final report

    International Nuclear Information System (INIS)

    Skipperud, L.; Popic, J.M.; Roos, P.; Salminen, S.; Nygren, U.; Sigmarsson, O.; Palsson, S.E.

    2011-05-01

    Radiometric determination methods, such as alpha spectrometry require long counting times when low activities are to be determined. Mass spectrometric techniques as Inductively Coupled Plasma Mass Spectrometry (ICP-MS), Thermal Ionisation Mass Spectrometry (TIMS) and Accelerator Mass Spectrometry (AMS) have shown several advantages compared to traditional methods when measuring long-lived radionuclides. Mass spectrometric methods for determination of very low concentrations of elemental isotopes, and thereby isotopic ratios, have been developed using a variety of ion sources. Although primarily applied to the determination of the lighter stable element isotopes and radioactive isotopes in geological studies, the techniques can equally well be applied to the measurement of activity concentrations of long-lived low-level radionuclides in various samples using 'isotope dilution' methods such as those applied in inductively coupled plasma mass spectrometry (ICP-MS). Due to the low specific activity of long-lived radionuclides, many of these are more conveniently detected using mass spectrometric techniques. Mass spectrometry also enables the individual determination of Pu-239 and Pu-240, which cannot be obtained by alpha spectrometry. Inductively Coupled Plasma Mass Spectrometry (ICP-MS) are rapidly growing techniques for the ultra-trace analytical determination of stable and long-lived isotopes and have a wide potential within environmental science, including ecosystem tracers and radio ecological studies. Such instrumentation, of course needs good radiochemical separation, to give best performance. The objectives of the project is to identify current needs and problems within low-level determination of long-lived radioisotopes by ICP-MS, to perform intercalibration and development and improvement of ICP-MS methods for the measurement of radionuclides and isotope ratios and to develop new methods based on modified separation chemistry applied to new auxiliary

  13. Method-MS. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Skipperud, L.; Popic, J.M. (Norwegian Univ. of Life Science (UMB), Isotope Lab. (Norway)); Roos, P. (Technical Univ. of Denmark, Risoe National Lab. for Sustainable Energy, Roskilde (Denmark)); Salminen, S. (Univ. of Helsinki (UH) (Finland)); Nygren, U. (Swedish Defence Research Agency (FOI) (Sweden)); Sigmarsson, O.; Palsson, S.E. (Univ. of Iceland/Icelandic Radiation Protection Institute (Iceland))

    2011-05-15

    Radiometric determination methods, such as alpha spectrometry require long counting times when low activities are to be determined. Mass spectrometric techniques as Inductively Coupled Plasma Mass Spectrometry (ICP-MS), Thermal Ionisation Mass Spectrometry (TIMS) and Accelerator Mass Spectrometry (AMS) have shown several advantages compared to traditional methods when measuring long-lived radionuclides. Mass spectrometric methods for determination of very low concentrations of elemental isotopes, and thereby isotopic ratios, have been developed using a variety of ion sources. Although primarily applied to the determination of the lighter stable element isotopes and radioactive isotopes in geological studies, the techniques can equally well be applied to the measurement of activity concentrations of long-lived low-level radionuclides in various samples using 'isotope dilution' methods such as those applied in inductively coupled plasma mass spectrometry (ICP-MS). Due to the low specific activity of long-lived radionuclides, many of these are more conveniently detected using mass spectrometric techniques. Mass spectrometry also enables the individual determination of Pu-239 and Pu-240, which cannot be obtained by alpha spectrometry. Inductively Coupled Plasma Mass Spectrometry (ICP-MS) are rapidly growing techniques for the ultra-trace analytical determination of stable and long-lived isotopes and have a wide potential within environmental science, including ecosystem tracers and radio ecological studies. Such instrumentation, of course needs good radiochemical separation, to give best performance. The objectives of the project is to identify current needs and problems within low-level determination of long-lived radioisotopes by ICP-MS, to perform intercalibration and development and improvement of ICP-MS methods for the measurement of radionuclides and isotope ratios and to develop new methods based on modified separation chemistry applied to new

  14. Development and Validation of an LC-MS/MS Method and Comparison with a GC-MS Method to Measure Phenytoin in Human Brain Dialysate, Blood, and Saliva

    Directory of Open Access Journals (Sweden)

    Raphael Hösli

    2018-01-01

    Full Text Available Phenytoin (PHT is one of the most often used critical dose drugs, where insufficient or excessive dosing can have severe consequences such as seizures or toxicity. Thus, the monitoring and precise measuring of PHT concentrations in patients is crucial. This study develops and validates an LC-MS/MS method for the measurement of phenytoin concentrations in different body compartments (i.e., human brain dialysate, blood, and saliva and compares it with a formerly developed GC-MS method that measures PHT in the same biological matrices. The two methods are evaluated and compared based on their analytical performance, appropriateness to analyze human biological samples, including corresponding extraction and cleanup procedures, and their validation according to ISO 17025/FDA Guidance for Industry. The LC-MS/MS method showed a higher performance compared with the GC-MS method. The LC-MS/MS was more sensitive, needed a smaller sample volume (25 µL and less chemicals, was less time consuming (cleaning up, sample preparation, and analysis, and resulted in a better LOD ( 0.995 for all tested matrices (blood, saliva, and dialysate. For larger sample numbers as in pharmacokinetic/pharmacodynamic studies and for bedside as well as routine analyses, the LC-MS/MS method offers significant advantages over the GC-MS method.

  15. ICP-MS: Analytical Method for Identification and Detection of Elemental Impurities.

    Science.gov (United States)

    Mittal, Mohini; Kumar, Kapil; Anghore, Durgadas; Rawal, Ravindra K

    2017-01-01

    Aim of this article is to review and discuss the currently used quantitative analytical method ICP-MS, which is used for quality control of pharmaceutical products. ICP-MS technique has several applications such as determination of single elements, multi element analysis in synthetic drugs, heavy metals in environmental water, trace element content of selected fertilizers and dairy manures. ICP-MS is also used for determination of toxic and essential elements in different varieties of food samples and metal pollutant present in the environment. The pharmaceuticals may generate impurities at various stages of development, transportation and storage which make them risky to be administered. Thus, it is essential that these impurities must be detected and quantified. ICP-MS plays an important function in the recognition and revealing of elemental impurities. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  16. [Rapid determination of illicit beta2-agonist additives in health foods and traditional Chinese patent medicines with DCBI-MS/MS method].

    Science.gov (United States)

    Hou, Yu-Lan; Wu, Shuang; Wang, Hua; Zhao, Yong; Liao, Peng; Tian, Qing-Qing; Sun, Wen-Jian; Chen, Bo

    2013-01-01

    A novel rapid method for detection of the illicit beta2-agonist additives in health foods and traditional Chinese patent medicines was developed with the desorption corona beam ionization mass spectrometry (DCBI-MS) technique. The DCBI conditions including temperature and sample volume were optimized according to the resulting mass spectra intensity. Matrix effect on 9 beta2-agonists additives was not significant in the proposed rapid determination procedure. All of the 9 target molecules were detected within 1 min. Quantification was achieved based on the typical fragment ion in MS2 spectra of each analyte. The method showed good linear coefficients in the range of 1-100 mg x L(-1) for all analytes. The relative deviation values were between 14.29% and 25.13%. Ten claimed antitussive and antiasthmatic health foods and traditional Chinese patent medicines from local pharmacies were analyzed. All of them were negative with the proposed DCBI-MS method. Without tedious sample pretreatments, the developed DCBI-MS is simple, rapid and sensitive for rapid qualification and semi-quantification of the illicit beta2-agonist additives in health foods and traditional Chinese patent medicines.

  17. Analytical Method Details (MS): SE29_MS1 [Metabolonote[Archive

    Lifescience Database Archive (English)

    Full Text Available SE29_MS1 LC-FT-ICR-MS ESI positive method 1 Agilent1100 HPLC (Agilent), LTQ-FT (The... (100mg) are solved in 300uL 80% methanol solution. 20uL sample is injected into HPLC after 0.2um membrane filter treatment. HPLC

  18. Measurement of methionine level with the LC-ESI-MS/MS method in schizophrenic patients.

    Science.gov (United States)

    Kulaksizoglu, S; Kulaksizoglu, B; Ellidag, H Y; Eren, E; Yilmaz, N; Baykal, A

    2016-01-01

    The purpose of this study was to evaluate plasma methionine levels by using liquid chromatography electrospray ionization-tandem mass spectroscopy (LC-ESI-MS/MS) in schizophrenic patients. A twelve-point standard graph was drawn, and the recovery rate, the intra-day and inter-day coefficients of variation (CV), the limit of detection (LOD), and the limit of quantification (LOQ) were evaluated. The y and R2 values of the standard graph equation were determined as 0.011x + 0.0179 and 0.9989, respectively, and the graph remained linear until the 200 µmol/l level. The intra-day coefficients of variation of the samples (n = 10) containing 8, 28, and 58 µmol/l methionine were determined as 2.68, 3.10, and 3.79%, respectively; while their inter-day coefficients of variation were determined as 2.98, 3.19, and 3.84%. The LOD and LOQ values were determined as 0.04 and 0.1 µmol/l, respectively, while the mean recovery rates were determined as 101.7 and 99.3%. Plasma methionine values were measured as 21.5 (19.5-24,6) µmol/l for the patient group, 17.8 (16.3-20.1) µmol/l for the control group, and the difference between the two groups was statistically significant (p = 0.03). LC-ESI-MS/MS method represents a fairly sensitive, economic, and rapid analysis that requires very little sample and is suitable for measuring methionine levels in schizophrenic patients.

  19. [Comparative analysis of methylation profiles in tissues of oral leukoplakia and oral squamous cell carcinoma].

    Science.gov (United States)

    Fu, J; Su, Y; Liu, Y; Zhang, X Y

    2018-04-09

    Objective: To compare the methylation profiles in tissues of oral leukoplakia (OLK) and oral squamous cell carcinoma (OSCC) with healthy tissues of oral mucosa, in order to identify the role of DNA methylation played in tumorigenesis. Methods: DNA samples extracted from tissues of 4 healthy oral mucosa, 4 OSCC and 4 OLK collected from patients of the Department of Oral Medicine, Capital Medical University School of Stomatology were examined and compared using Methylation 450 Bead Chip. The genes associated with differentially methylated CpG sites were selected for gene ontology (GO) analysis and Kyoto encyclopedia of genes and genomes (KEGG) pathway enrichment. Results: Multiple differentially methylated CpG sites were identified by using the above mentioned assay. Hypermethylation constitutes 86.18% (23 290/27 025) of methylation changes in OLK and hypomethylation accounts for 13.82% (3 734/27 025) of methylation changes. Both hypermethylated and hypomethylated CpG sites were markedly increased in OSCC tissue compared with OLK tissue. The majority of differentially methylated CpG sites were located outside CpG islands, with approximately one-fourth in CpG shores flanking the islands, which were considered highly important for gene regulation and tumorigenesis. Pathway analysis revealed that differentially methylated CpG sites in both OLK and OSCC patients shared the same pathway enrichments, most of which were correlated with carcinogenesis and cancer progression (e.g., DNA repair, cell cycle, and apoptosis). Conclusions: In the present study, methylation-associated alterations affect almost all pathways in the cellular network in both OLK and OSCC. OLK and OSCC shared similar methylation changes whether in pathways or genes, indicating that epigenetically they might have the same molecular basis for disease progression.

  20. Methods in endogenous steroid profiling - A comparison of gas chromatography mass spectrometry (GC-MS) with supercritical fluid chromatography tandem mass spectrometry (SFC-MS/MS).

    Science.gov (United States)

    Teubel, Juliane; Wüst, Bernhard; Schipke, Carola G; Peters, Oliver; Parr, Maria Kristina

    2018-06-15

    In various fields of endocrinology, the determination of steroid hormones synthesised by the human body plays an important role. Research on central neurosteroids has been intensified within the last years, as they are discussed as biomarkers for various cognitive disorders. Their concentrations in cerebrospinal fluid (CSF) are considered to be regulated independently from peripheral fluids. For that reason, the challenging matrix CSF becomes a very interesting specimen for analysis. Concentrations are expected to be very low and available amount of CSF is limited. Thus, a comprehensive method for very sensitive quantification of a set of analytes as large as possible in one analytical aliquot is desired. However, high structural similarities of the selected panel of 51 steroids and steroid sulfates, including numerous isomers, challenges achievement of chromatographic selectivity. Since decades the analysis of endogenous steroids in various body fluids is mainly performed by gas chromatography (GC) coupled to (tandem) mass spectrometry (MS(/MS)). Due to the structure of the steroids of interest, derivatisation is performed to meet the analytical requirements for GC-MS(/MS). Most of the laboratories use a two-step derivatisation in multi-analyte assays that was already published in the 1980s. However, for some steroids this elaborate procedure yields multiple isomeric derivatives. Thus, some laboratories utilize (ultra) high performance liquid chromatography ((U)HPLC)-MS/MS as alternative but, even UHPLC is not able to separate some of the isomeric pairs. Supercritical fluid chromatography (SFC) as an orthogonal separation technique to GC and (U)HPLC may help to overcome these issues. Within this project the two most promising methods for endogenous steroid profiling were investigated and compared: the "gold standard" GC-MS and the orthogonal separation technique SFC-MS/MS. Different derivatisation procedures for gas chromatographic detection were explored and the

  1. Improved LC-MS/MS method for the quantification of hepcidin-25 in clinical samples.

    Science.gov (United States)

    Abbas, Ioana M; Hoffmann, Holger; Montes-Bayón, María; Weller, Michael G

    2018-06-01

    Mass spectrometry-based methods play a crucial role in the quantification of the main iron metabolism regulator hepcidin by singling out the bioactive 25-residue peptide from the other naturally occurring N-truncated isoforms (hepcidin-20, -22, -24), which seem to be inactive in iron homeostasis. However, several difficulties arise in the MS analysis of hepcidin due to the "sticky" character of the peptide and the lack of suitable standards. Here, we propose the use of amino- and fluoro-silanized autosampler vials to reduce hepcidin interaction to laboratory glassware surfaces after testing several types of vials for the preparation of stock solutions and serum samples for isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS). Furthermore, we have investigated two sample preparation strategies and two chromatographic separation conditions with the aim of developing a LC-MS/MS method for the sensitive and reliable quantification of hepcidin-25 in serum samples. A chromatographic separation based on usual acidic mobile phases was compared with a novel approach involving the separation of hepcidin-25 with solvents at high pH containing 0.1% of ammonia. Both methods were applied to clinical samples in an intra-laboratory comparison of two LC-MS/MS methods using the same hepcidin-25 calibrators with good correlation of the results. Finally, we recommend a LC-MS/MS-based quantification method with a dynamic range of 0.5-40 μg/L for the assessment of hepcidin-25 in human serum that uses TFA-based mobile phases and silanized glass vials. Graphical abstract Structure of hepcidin-25 (Protein Data Bank, PDB ID 2KEF).

  2. A novel UPLC-MS/MS method for sensitive quantitation of boldine in plasma, a potential anti-inflammatory agent: application to a pharmacokinetic study in rats.

    Science.gov (United States)

    Zeng, Rong-Jie; Li, Yu; Chen, Jian-Zhong; Chou, Gui-Xin; Gao, Yu; Shao, Jing-Wei; Jia, Lee; Wu, Sheng-Dong; Wu, Shui-Sheng

    2015-03-01

    Boldine is a potential anti-inflammatory agent found in several different plants. Published bioanalytical methods using HPLC with ultraviolet and fluorescent detection lacked enough sensitivity and required tedious sample preparation procedures. Herein, we describe the development of a novel ultra-high performance LC with MS/MS for determination of boldine in plasma. Boldine in plasma was recovered by liquid-liquid extraction using 1 mL of methyl tert-butyl ether. Chromatographic separation was performed on a C18 column at 45°C, with a gradient elution consisting of acetonitrile and water containing 0.1% (v/v) formic acid at a flow rate of 0.3 mL/min. The detection was performed on an electrospray triple-quadrupole MS/MS by positive ion multiple reaction monitoring mode. Good linearity (r(2) > 0.9926) was achieved in a concentration range of 2.555-2555 ng/mL with a lower limit of quantification of 2.555 ng/mL for boldine. The intra- and inter-day precisions of the assay were 1.2-6.0 and 1.8-7.4% relative standard deviation with an accuracy of -6.0-8.0% relative error. This newly developed method was successfully applied to a single low-dose pharmacokinetic study in rats and was demonstrated to be simpler and more sensitive than the published methods, allowing boldine quantification in reduced plasma volume. Copyright © 2014 John Wiley & Sons, Ltd.

  3. A DNA microarray-based methylation-sensitive (MS)-AFLP hybridization method for genetic and epigenetic analyses.

    Science.gov (United States)

    Yamamoto, F; Yamamoto, M

    2004-07-01

    We previously developed a PCR-based DNA fingerprinting technique named the Methylation Sensitive (MS)-AFLP method, which permits comparative genome-wide scanning of methylation status with a manageable number of fingerprinting experiments. The technique uses the methylation sensitive restriction enzyme NotI in the context of the existing Amplified Fragment Length Polymorphism (AFLP) method. Here we report the successful conversion of this gel electrophoresis-based DNA fingerprinting technique into a DNA microarray hybridization technique (DNA Microarray MS-AFLP). By performing a total of 30 (15 x 2 reciprocal labeling) DNA Microarray MS-AFLP hybridization experiments on genomic DNA from two breast and three prostate cancer cell lines in all pairwise combinations, and Southern hybridization experiments using more than 100 different probes, we have demonstrated that the DNA Microarray MS-AFLP is a reliable method for genetic and epigenetic analyses. No statistically significant differences were observed in the number of differences between the breast-prostate hybridization experiments and the breast-breast or prostate-prostate comparisons.

  4. Finding of pesticides in fashionable fruit juices by LC-MS/MS and GC-MS/MS.

    Science.gov (United States)

    Tran, Kevin; Eide, David; Nickols, Susan M; Cromer, Michele R; Sabaa-Srur, Armando; Smith, Robert E

    2012-10-15

    Products labelled as containing extracts from two mushrooms (cordyceps plus reishi) and the juices from açaí, goji, mangosteen, noni, pomegranate, and sea buckthorn have been analysed for 174 different pesticides, using the validated QuEChERS method for sample preparation and electrospray LC-MS/MS in the positive ion mode for analysis. Pesticides were found in 10 of the 21 samples analysed. Most pesticides found were below the tolerance levels (1-6 μg/g, depending on the pesticide), but some were not. This included boscalid, dimethomorph, iprovalicarb, pyridaben, pyrimethanil, and imazalil, for which there is no tolerance reported or zero tolerance in any fruit. However, genuine açaí that was harvested in the state of Pará and lyophilised in Rio de Janeiro had no detectable pesticides, when analysed by both LC-MS/MS and GC-MS/MS, which can detect 213 more pesticides and industrial chemicals. Likewise no pesticides were found in one sample each of cordyceps plus reishi, sea buckthorn and noni. Published by Elsevier Ltd.

  5. A Modified LC/MS/MS Method with Enhanced Sensitivity for the Determination of Scopolamine in Human Plasma

    Science.gov (United States)

    Wang, Zuwei; Vaksman, Zalman; Putcha, Lakshmi

    2008-01-01

    Intranasal scopolamine is a choice drug for the treatment of motion sickness during space flight because of its quick onset of action, short half-life and favorable sideeffects profile. The dose administered usually ranges between 0.1 and 0.4 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids using existing sensitive LC/MS/MS method, especially when the biological sample volumes are limited. To measure scopolamine in human plasma to facilitate pharmacokinetic evaluation of the drug, we developed a sensitive LC/MS/MS method using 96 well micro elution plates for solid phase extraction (SPE) of scopolamine in human plasma. Human plasma (100-250 micro L) were loaded onto Waters Oasis HLB 96 well micro elution plate and eluted with 50 L of organic solvent without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 3 minutes. The mobile phase for separation was 80:20 (v/v) methanol: ammonium acetate (30 mM) in water. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 right arrow 138.1 and internal standard hyoscyamine m/z = 290.2 right arrow 124.1. The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at about 1.1 and 1.7 min respectively. The linear range is 25-10000 pg/mL for scopolamine in human plasma with correlation coefficients greater than 0.99 and CV less than 0.5%. The intra-day and inter-day CVs are less than 15% for quality control samples with concentrations of 75,300, and 750 pg/mL of scopolamine in human plasma. SPE using 96 well micro elution plates allows rapid sample preparation and enhanced sensitivity for the LC/MS/MS

  6. siMS Score: Simple Method for Quantifying Metabolic Syndrome

    OpenAIRE

    Soldatovic, Ivan; Vukovic, Rade; Culafic, Djordje; Gajic, Milan; Dimitrijevic-Sreckovic, Vesna

    2016-01-01

    Objective To evaluate siMS score and siMS risk score, novel continuous metabolic syndrome scores as methods for quantification of metabolic status and risk. Materials and Methods Developed siMS score was calculated using formula: siMS score = 2*Waist/Height + Gly/5.6 + Tg/1.7 + TAsystolic/130?HDL/1.02 or 1.28 (for male or female subjects, respectively). siMS risk score was calculated using formula: siMS risk score = siMS score * age/45 or 50 (for male or female subjects, respectively) * famil...

  7. Rapid Determination of Isomeric Benzoylpaeoniflorin and Benzoylalbiflorin in Rat Plasma by LC-MS/MS Method

    Directory of Open Access Journals (Sweden)

    Chuanqi Zhou

    2017-01-01

    Full Text Available Benzoylpaeoniflorin (BP is a potential therapeutic agent against oxidative stress related Alzheimer’s disease. In this study, a more rapid, selective, and sensitive liquid chromatography-tandem mass spectrometric (LC-MS/MS method was developed to determine BP in rat plasma distinguishing with a monoterpene isomer, benzoylalbiflorin (BA. The method showed a linear response from 1 to 1000 ng/mL (r>0.9950. The precision of the interday and intraday ranged from 2.03 to 12.48% and the accuracy values ranged from −8.00 to 10.33%. Each running of the method could be finished in 4 minutes. The LC-MS/MS method was validated for specificity, linearity, precision, accuracy, recovery, and stability and was found to be acceptable for bioanalytical application. Finally, this fully validated method was successfully applied to a pharmacokinetic study in rats following oral administration.

  8. Fourier-transform-infrared-spectroscopy based spectral-biomarker selection towards optimum diagnostic differentiation of oral leukoplakia and cancer.

    Science.gov (United States)

    Banerjee, Satarupa; Pal, Mousumi; Chakrabarty, Jitamanyu; Petibois, Cyril; Paul, Ranjan Rashmi; Giri, Amita; Chatterjee, Jyotirmoy

    2015-10-01

    In search of specific label-free biomarkers for differentiation of two oral lesions, namely oral leukoplakia (OLK) and oral squamous-cell carcinoma (OSCC), Fourier-transform infrared (FTIR) spectroscopy was performed on paraffin-embedded tissue sections from 47 human subjects (eight normal (NOM), 16 OLK, and 23 OSCC). Difference between mean spectra (DBMS), Mann-Whitney's U test, and forward feature selection (FFS) techniques were used for optimising spectral-marker selection. Classification of diseases was performed with linear and quadratic support vector machine (SVM) at 10-fold cross-validation, using different combinations of spectral features. It was observed that six features obtained through FFS enabled differentiation of NOM and OSCC tissue (1782, 1713, 1665, 1545, 1409, and 1161 cm(-1)) and were most significant, able to classify OLK and OSCC with 81.3 % sensitivity, 95.7 % specificity, and 89.7 % overall accuracy. The 43 spectral markers extracted through Mann-Whitney's U Test were the least significant when quadratic SVM was used. Considering the high sensitivity and specificity of the FFS technique, extracting only six spectral biomarkers was thus most useful for diagnosis of OLK and OSCC, and to overcome inter and intra-observer variability experienced in diagnostic best-practice histopathological procedure. By considering the biochemical assignment of these six spectral signatures, this work also revealed altered glycogen and keratin content in histological sections which could able to discriminate OLK and OSCC. The method was validated through spectral selection by the DBMS technique. Thus this method has potential for diagnostic cost minimisation for oral lesions by label-free biomarker identification.

  9. Stability of γ-Hydroxybutyrate in Blood Samples from Impaired Drivers after Storage at 4°C and Comparison of GC–FID–GBL and LC–MS-MS Methods of Analysis

    DEFF Research Database (Denmark)

    Jones, Alan Wayne; Gladh, Sven-Åke; Windberg, Charlotte Norup

    2015-01-01

    The stability of γ-hydroxybutyrate (GHB) was determined in 50 blood samples from impaired drivers after storage at 4 °: C for up to 12 months. GHB was determined in whole blood by gas chromatography-flame ionization detector (GC-FID) after conversion into γ-butyrolactone (GBL) and results were......-MS-MS method (x-variate) were highly correlated (R(2) = 0.974). The regression equation was y = 0.85x + 2.2 and residual standard deviation (SD) was 7.8 mg/kg. The y-intercept (2.2 mg/kg) was not significantly different from zero (P > 0.05), although the slope of the regression line (0.85) differed from unity...

  10. Short Communication: Testosterone Measured with an Automatic Immunoassay Compares Reasonbly Well to Results Obtained by LC-MS/MS

    DEFF Research Database (Denmark)

    Knudsen, Cindy Søndersø; Højskov, Carsten Schriver; Møller, Holger Jon

    2016-01-01

    Background: Previous studies have reported problems measuring testosterone with immunological assays. Here we explore an automatic second generation immunoassay compared to a LC-MS/MS method. Methods: We collected blood samples from 76 women and measured testosterone, progesterone, gender...... hormonebinding globulin (SHBG), and albumin employing Cobas e601/c501. Testosterone, androstenedione (andro), dehydroepiandrosterone sulphate (DHEAS), and 17-hydroxyprogesterone (17-OHP) concentrations were measured employing LC-MS/MS. We evaluated the difference between testosterone measured by the two methods...... and examined the potential interference from the selected steroids and bindings proteins. Results: Testosterone concentrations measured by the two methods yielded: Cobas e601 = 1.240 x (LC-MS/MS) - 0.197, r = 0.84, for testosterone concentrations between 0.22 - 4.9 nmol/L. A positive correlation was observed...

  11. Method-MS, final report 2010

    DEFF Research Database (Denmark)

    Skipperud, Lindis; Popic, Jelena M.; Roos, Per

    Radiometric determination methods, such as alpha spectrometry require long counting times when low activities are to be determined. Mass spectrometric techniques as Inductively Coupled Plasma Mass Spectrometry (ICP-MS), Thermal Ionisation Mass Spectrometry (TIMS) and Accelerator Mass Spectrometry...

  12. Sensitivity of GC-EI/MS, GC-EI/MS/MS, LC-ESI/MS/MS, LC-Ag(+) CIS/MS/MS, and GC-ESI/MS/MS for analysis of anabolic steroids in doping control.

    Science.gov (United States)

    Cha, Eunju; Kim, Sohee; Kim, Ho Jun; Lee, Kang Mi; Kim, Ki Hun; Kwon, Oh-Seung; Lee, Jaeick

    2015-01-01

    This study compared the sensitivity of various separation and ionization methods, including gas chromatography with an electron ionization source (GC-EI), liquid chromatography with an electrospray ionization source (LC-ESI), and liquid chromatography with a silver ion coordination ion spray source (LC-Ag(+) CIS), coupled to a mass spectrometer (MS) for steroid analysis. Chromatographic conditions, mass spectrometric transitions, and ion source parameters were optimized. The majority of steroids in GC-EI/MS/MS and LC-Ag(+) CIS/MS/MS analysis showed higher sensitivities than those obtained with other analytical methods. The limits of detection (LODs) of 65 steroids by GC-EI/MS/MS, 68 steroids by LC-Ag(+) CIS/MS/MS, 56 steroids by GC-EI/MS, 54 steroids by LC-ESI/MS/MS, and 27 steroids by GC-ESI/MS/MS were below cut-off value of 2.0 ng/mL. LODs of steroids that formed protonated ions in LC-ESI/MS/MS analysis were all lower than the cut-off value. Several steroids such as unconjugated C3-hydroxyl with C17-hydroxyl structure showed higher sensitivities in GC-EI/MS/MS analysis relative to those obtained using the LC-based methods. The steroids containing 4, 9, 11-triene structures showed relatively poor sensitivities in GC-EI/MS and GC-ESI/MS/MS analysis. The results of this study provide information that may be useful for selecting suitable analytical methods for confirmatory analysis of steroids. Copyright © 2015 John Wiley & Sons, Ltd.

  13. Analytical Method Details (MS): SE60_MS01 [Metabolonote[Archive

    Lifescience Database Archive (English)

    Full Text Available stem and Waters Q-Tof Premier UPLC-QTOF-MS ESI Positive The supernatant (3 μl) were subsequently subjected to metabolome...g were conducted according to a previously described method (Matsuda et al., 2009, 2010). Briefly, metabolome

  14. Modified Method for Detection of Benzoylecgonine in Human Urine by GC-MS: Derivatization Using Pentafluoropropanol/Acetic Anhydride.

    Science.gov (United States)

    Serafin, Michelle C; Paulemon, Kasandra M; Fuller, Zachary J; Bronner, William E

    2017-05-01

    An existing GC-MS method for detecting benzoylecgonine (BZE) in urine was modified by changing derivatizing reagents. This method modification presents a cost-effective alternative derivatization procedure for the detection of BZE in urine by GC-MS. The combination of pentafluoropropanol and acetic anhydride was found to produce the same reaction product for BZE as pentafluoropropanol with pentafluoropropionic anhydride, while reducing reagent cost. With no anhydride present, derivatization of BZE by pentafluoropropanol did not occur. Published by Oxford University Press 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  15. Cannabinoids determination in oral fluid by SPME-GC/MS and UHPLC-MS/MS and its application on suspected drivers.

    Science.gov (United States)

    Anzillotti, Luca; Castrignanò, Erika; Strano Rossi, Sabina; Chiarotti, Marcello

    2014-12-01

    The confirmation of Δ9-tetrahydrocannabinol (THC) in oral fluid (OF) is an important issue for assessing Driving Under the Influence of Drugs (DUID). The aim of this research was to develop a highly sensitive method with minimal sample pre-treatment suitable for the analysis of small OF volumes (100 μL) for the confirmation of cannabinoids in DUID cases. Two methods were compared for the confirmation of THC in residual OF samples, obtained from a preliminary on-site screening with commercial devices. An ultra high performance LC-MS (UHPLC-MS/MS) method and an SPME-GC/MS method were hence developed. 100 μL of the residual mixture OF/preservative buffer or neat OF was simply added to 10 μL of THC-D3 (1 μg/mL) and submitted to the two different analyses: A - direct injection of 10 μL in UHPLC-MS/MS in positive electrospray ionisation (ESI) mode and B - sampling for 30 min with SPME (100 μm polydimethylsiloxane or PDMS fibre) and direct injection by desorption of the fibre in the GC injection port. The lowest limit of detection (LLOD) of THC was 2 ng/mL in UHPLC-MS/MS and 0.5 ng/mL in SPME-GC/MS. In addition, cannabidiol (CBD) and cannabinol (CBN) could be detected in GC/MS equipment at 2 ng/mL, whilst in UHPLC-MS/MS the LLOD was 20 ng/mL. Both methods were applied to 70 samples coming from roadside tests. By SPME-GC/MS analysis, THC was confirmed in 42 samples, whilst CBD was detected in 21 of them, along with CBN in 14 samples. THC concentrations ranged from traces below the lowest limit of quantification or LLOQ (2 ng/mL) up to 690 ng/mL. Copyright © 2014 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  16. Evaluation of various QuEChERS based methods for the analysis of herbicides and other commonly used pesticides in polished rice by LC-MS/MS.

    Science.gov (United States)

    Pareja, Lucía; Cesio, Verónica; Heinzen, Horacio; Fernández-Alba, Amadeo R

    2011-02-15

    Four different extraction and clean-up protocols based on the QuEChERS method were compared for the development of an optimized sample preparation procedure for the multiresidue analysis of 16 commonly applied herbicides in rice crops using LC-QqQ/MS. Additionally the methods were evaluated for the analysis of 26 insecticides and fungicides currently used in rice crops. The methods comprise, in general, the hydratation of the sample with water followed by the extraction with acetonitrile, phase separation with the addition of different salts and finally a clean-up step with various sorbents. Matrix effects were evaluated for the 4 studied methods using LC-QqQ/MS. Additionally LC-TOF/MS was used to compare the co-extractants obtained with the four assayed methodologies. Thirty-six pesticides presented good performance with recoveries in the range 70-120% and relative standard deviations below 20% using 7.5 g of milled polished rice and the buffered acetate QuEChERS method without clean-up at both fortification levels: 10 and 300 μg kg(-1). The other six pesticides presented low recovery rates, nevertheless all these analytes could be analyzed with at least one of the other three studied procedures. Copyright © 2010. Published by Elsevier B.V.

  17. Segmental analysis of amphetamines in hair using a sensitive UHPLC-MS/MS method.

    Science.gov (United States)

    Jakobsson, Gerd; Kronstrand, Robert

    2014-06-01

    A sensitive and robust ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated for quantification of amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine and 3,4-methylenedioxy methamphetamine in hair samples. Segmented hair (10 mg) was incubated in 2M sodium hydroxide (80°C, 10 min) before liquid-liquid extraction with isooctane followed by centrifugation and evaporation of the organic phase to dryness. The residue was reconstituted in methanol:formate buffer pH 3 (20:80). The total run time was 4 min and after optimization of UHPLC-MS/MS-parameters validation included selectivity, matrix effects, recovery, process efficiency, calibration model and range, lower limit of quantification, precision and bias. The calibration curve ranged from 0.02 to 12.5 ng/mg, and the recovery was between 62 and 83%. During validation the bias was less than ±7% and the imprecision was less than 5% for all analytes. In routine analysis, fortified control samples demonstrated an imprecision <13% and control samples made from authentic hair demonstrated an imprecision <26%. The method was applied to samples from a controlled study of amphetamine intake as well as forensic hair samples previously analyzed with an ultra high performance liquid chromatography time of flight mass spectrometry (UHPLC-TOF-MS) screening method. The proposed method was suitable for quantification of these drugs in forensic cases including violent crimes, autopsy cases, drug testing and re-granting of driving licences. This study also demonstrated that if hair samples are divided into several short segments, the time point for intake of a small dose of amphetamine can be estimated, which might be useful when drug facilitated crimes are investigated. Copyright © 2014 John Wiley & Sons, Ltd.

  18. Development of an LC-MS/MS method for the determination of pesticides and patulin in apples

    DEFF Research Database (Denmark)

    Christensen, Hanne Bjerre; Poulsen, Mette Erecius; Rasmussen, Peter Have

    2009-01-01

    A method for the simultaneous determination of 33 pesticides or degradation products together with patulin in apples by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed. The method involved homogenization of the apples, extraction with ammonium acetate-acetic acid solution...... in methanol-water by ultrasonication, filtration, and determination by LC-MS/MS. The repeatability and within-laboratory reproducibility for the three spiking levels 0.02, 0.04 and 0.2 mg kg(-1) were between 4% and 35%. In general, the repeatability and reproducibility were about 10-20%. The limits...... of quantification (LOQs) were between 0.01 and 0.14 mg kg(-1). The method was used on incurred samples from parts of the ISAFRUIT project financed by the European Commission under the 6th Framework Programme. Samples were analysed at four different stages: after harvest, after storage (controlled), after a water...

  19. Development and validation of an LC-MS/MS method for quantification of cyclic guanosine 3',5'-monophosphate (cGMP) in clinical applications: a comparison with a EIA method.

    Science.gov (United States)

    Zhang, Yanhua; Dufield, Dawn; Klover, Jon; Li, Wenlin; Szekely-Klepser, Gabriella; Lepsy, Christopher; Sadagopan, Nalini

    2009-02-15

    An LC-MS/MS method was developed and validated to quantify endogenous cyclic guanosine 3',5'-monophosphate (cGMP) in human plasma. The LC-MS/MS and competitive enzyme immunoassay (EIA) assays were compared. cGMP concentrations of 20 human plasma samples were measured by both methods. For the MS-based assay, plasma samples were subjected to a simple protein precipitation procedure by acetonitrile prior to analysis by electrospray ionization LC-MS/MS. De-protonated analytes generated in negative ionization mode were monitored through multiple reaction monitoring (MRM). A stable isotope-labeled internal standard, (13)C(10),(15)N(5)-cGMP, which was biosynthesized in-house, was used in the LC-MS/MS method. The competitive EIA was validated using a commercially available cGMP fluorescence assay kit. The intra-assay accuracy and precision for MS-based assay for cGMP were 6-10.1% CV and -3.6% to 7.3% relative error (RE), respectively, while inter-assay precision and accuracy were 5.6-8.1% CV and -2.1% to 6.3% RE, respectively. The intra-assay accuracy and precision for EIA were 17.9-27.1% CV and -4.9% to 24.5% RE, respectively, while inter-assay precision and accuracy were 15.1-39.5% CV and -30.8% to 4.37% RE, respectively. Near the lower limits of detection, there was little correlation between the cGMP concentration values in human plasma generated by these two methods (R(2)=0.197, P=0.05). Overall, the MS-based assay offered better selectivity, recovery, precision and accuracy over a linear range of 0.5-20ng/mL. The LC-MS/MS method provides an effective tool for the quantitation of cGMP to support clinical mechanistic studies of curative pharmaceuticals.

  20. [Simultaneous determination of amlodipine, benazepril and benazeprilat in human plasma by LC-HESI/MS/MS method].

    Science.gov (United States)

    Pan, Hua-Ling; Lin, Li-Shan; Ding, Jue-Fang; Chen, Xiao-Yan; Zhong, Da-Fang

    2014-01-01

    The study aims to develop a rapid, sensitive and specified method of liquid chromatography with heated electrospray ionization tandem mass spectrometry (LC-HESI/MS/MS) for simultaneous determination of amlodipine, benazepril and benazeprilat in human plasma using amlodipine-d4 and ubenimex as internal standards (ISs). Selected reaction monitoring (SRM) with heated electrospray ionization (HESI) was used in the positive mode for mass spectrometric detection. Analytes and ISs were extracted from plasma by simple protein precipitation. The reconstituted samples were chromatographed on a C18 (100 mm x 4.6 mm, 5 microm) column with mixture of methanol-acetonitrile-5 mmol.L- ammonium acetate-formic acid (30 : 30 : 40 : 0.1) as mobile phase at a flow rate of 0.6 mL.min-1. The standard curves were demonstrated to be linear in the range of 0.02 to 6.00 ng.mL-1 for amlodipine, 0.2 to 1,500 ng.mL-1 for benazepril and benazeprilat with r2>0.99 for each analyte. The lower limit of quantitation was identifiable and reproducible at 0.02, 0.2 and 0.2 ng mL-1 for amlodipine, benazepril and benazeprilat, respectively. The intra-day and inter-day precision and accuracy results were within the acceptable limit across all concentrations. The plasma samples were stable after four freeze-thaw cycles and being stored for 93 days at -20 degrees C. The method was applied to a pharmacokinetic study of a fixed-dose combination of amlodipine and benazepril on Chinese healthy volunteers.

  1. Determination of morphine, codeine and 6-monoacetylmorphine in saliva of substance-abuse patients using HPLC/MS methods

    Directory of Open Access Journals (Sweden)

    Milovanović Vesna

    2012-01-01

    Full Text Available Background/Aim. Saliva represents an alternative specimen for substances abuse determination in toxicology. Hence, the aim of this study was to optimize a method for saliva specimen preparation for heroin metabolites, morphine and 6-monoacetylmorphine (6-mam, and codeine determination by liquid chromatography-mass spectrometry (LC/MS, and to apply this method on saliva samples taken from the patients. Methods. Saliva specimen was prepared using liqiud/liquid extraction of morphine, codeine and 6- mam by mixture of chloroform and isopropanol (9 : 1; v/v. Extracts were analysed by HPLC/MS technique: separation column Waters Spherisorb® 5 μm, ODS2, 4.6 × 100 mm; mobile phase: ammonium acetate : acetonitile (80 : 20; v/v, mobile phase flow rate 0.3 mL/min; mass detection range: 100-400 m/z. Regression and correlation analyses were performed with the probalility level of 0.05. Concentrations of morphine, codeine and 6-mam were determined in saliva samples of the patients with “opiates” in urine identified by the test strips. Results. Calibration for each analysed substance was done in the concentration range from 0.1 to 1 mg/L and the coefficient of correlation was R2 > 0.99. We obtained following calibration curves: y = 385531x + 14584; y = 398036x + 31542; and y = 524162x - 27105, for morphine, codeine and 6-mam, respectively. Recovery for morphine and codeine determination was 99%, while for 6- mam it was 94%. Limits of detection and quantification of a proposed method were 0.01 mg/L and 0.05 mg/L, respectively. Concentration of morphine in the saliva of the heroin users ranged between 0.54 and 5.82 mg/L, concentration of codeine between 0.05 and 5.33, and 6-mam between 0.01 and 0.68 mg/L. A statistically significant correlation between codeine and 6-mam concentrations was obtained. Conclusion. A proposed HPLC/MS method for morphine, codeine and 6-mam determination in saliva is accurate, simple, cheap and suitable for routine analysis and

  2. A Simple and Direct LC-MS Method for Determination of Genotoxic Impurity Hydroxylamine in Pharmaceutical compounds.

    Science.gov (United States)

    Kumar, Thangarathinam; Ramya, Mohandass; Srinivasan, Viswanathan; Xavier, N

    2017-08-01

    Hydroxylamine is a known genotoxic impurity compound that needs to be controlled down to ppm level in pharmaceutical processes. It is difficult to detect using conventional analytical techniques due to its physio-chemical properties like lack of chromophore, low molecular weight, absence of carbon atom and high polarity. In addition to that, analysis of the pharmaceutical samples encounters considerable obstruction from matrix components that greatly overshadow the response of hydroxylamine. This study describes a simple, sensitive and direct Liquid Chromatographic-Mass Spectrometric method (LC-MS) for detection of hydroxylamine in pharmaceutical compounds. The LC-MS method was detected up to 0.008 ppm of hydroxylamine with S/N > 3.0 and quantified up to 0.025 ppm of hydroxylamine with S/N ratio >10.0. This validated method can be applied as a generic method to detect the hydroxylamine for pharmaceutical process control and drug substance release. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. UPLC-MS/MS Method for Simultaneous Determination of Three Major Metabolites of Mequindox in Holothurian

    Directory of Open Access Journals (Sweden)

    Huihui Liu

    2018-01-01

    Full Text Available This study developed an ultraperformance liquid chromatography tandem mass spectrometry (UPLC-MS/MS method for the detection of three major metabolites of mequindox, including 3-methyl-quinoxaline-2-carboxylic acid, 1-desoxymequindox, and 1,4-bisdesoxymequindox (MQCA, 1-DMEQ, and BDMEQ, in holothurian. Target analytes were simplified with ultrasound-assisted acidolysis extracted without complicated enzymolysis steps. After that, each sample was centrifuged and purified by an Oasis MAX cartridge. Then, the processed samples were separated and monitored by UPLC-MS/MS. This developed method has been validated according to FDA criteria. At fortified levels of 2, 10, and 20 μg/kg, recoveries ranged from 82.5% to 93.5% with the intraday RSD less than 7.27% and interday RSD less than 11.8%. The limit of detection (LOD of all the three metabolites ranged from 0.21 to 0.48 μg/kg, while the limit of quantification (LOQ ranged from 0.79 to 1.59 μg/kg. On application to commercial samples, 14 of 20 samples were detected positive for the three target analytes, with positive rate at 70 percentage. The result indicated that this method was specific, sensitive, and suitable for the quantification and conformation of the three major metabolites of MEQ in holothurian.

  4. Sensitive quantification of apomorphine in human plasma using a LC-ESI-MS-MS method.

    Science.gov (United States)

    Abe, Emuri; Alvarez, Jean-Claude

    2006-06-01

    An analytical method based on liquid chromatography coupled with ion trap mass spectrometry (MS) detection with electrospray ionization interface has been developed for the identification and quantification of apomorphine in human plasma. Apomorphine was isolated from 0.5 mL of plasma using a liquid-liquid extraction with diethyl ether and boldine as internal standard, with satisfactory extraction recoveries. Analytes were separated on a 5-microm C18 Highpurity (Thermohypersil) column (150 mm x 2.1 mm I.D.) maintained at 30 degrees C, coupled to a precolumn (C18, 5-microm, 10 mm x 2.0 mm I.D., Thermo). The elution was achieved isocratically with a mobile phase of 2 mM NH4COOH buffer pH 3.8/acetonitrile (50/50, vol/vol) at a flow rate of 200 microL per minute. Data were collected either in full-scan MS mode at m/z 150 to 500 or in full-scan tandem mass spectrometry mode, selecting the [M+H]ion at m/z 268.0 for apomorphine and m/z 328.0 for boldine. The most intense daughter ion of apomorphine (m/z 237.1) and boldine (m/z 297.0) were used for quantification. Retention times were 2.03 and 2.11 minutes for boldine and apomorphine, respectively. Calibration curves were linear in the 0.025 to 20 ng/mL range. The limits of detection and quantification were 0.010 ng/mL and 0.025 ng/mL, respectively. Accuracy and precision of the assay were measured by analyzing 54 quality control samples for 3 days. At concentrations of 0.075, 1.5, and 15 ng/mL, intraday precisions were less than 10.1%, 5.3%, and 3.8%, and interday precisions were less than 4.8%, 6.6%, and 6.5%, respectively. Accuracies were in the 99.5 to 104.2% range. An example of a patient who was given 6 mg of apomorphine subcutaneously is shown, with concentrations of 14.1 ng/mL after 30 minutes and 0.20 ng/mL after 6 hours. The method described enables the unambiguous identification and quantification of apomorphine with very good sensitivity using only 0.5 mL of sample, and is very convenient for therapeutic drug

  5. A UPLC-MS/MS method for analysis of vancomycin in human cerebrospinal fluid and comparison with the chemiluminescence immunoassay.

    Science.gov (United States)

    Mei, Shenghui; Wang, Jiaqing; Zhu, Leting; Chen, Ruiling; Li, Xingang; Chen, Kai; Chen, Guangqiang; Zhou, Jianxin; Wang, Qiang; Zhao, Zhigang

    2017-08-01

    Vancomycin (VCM) is clinically used in treating patients with postoperative intracranial infections. The cerebrospinal fluid (CSF) concentration of VCM varies greatly among patients. To guide the dosage regimens, monitoring of VCM in CSF is needed. However a method for analysis of VCM in human CSF is lacking. An ultraperformance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) was developed and validated for analysis of VCM in human CSF, and the agreement of UPLC-MS/MS and chemiluminescence immunoassay (CLIA) in the analysis of CSF VCM was evaluated. The ion transitions were m/z 725.5 > 144.1 for VCM and m/z 455.2 > 308.2 for methotrexate (internal standard). The agreement between UPLC-MS/MS and CLIA was evaluated by Bland-Altman plot in 179 samples. The calibration range of the UPLC-MS/MS method was 1-400 mg/L. The inaccuracy and imprecision were -0.69-10.80% and  0.98). The 95% limit of agreement of the ratio of CLIA to UPLC-MS/MS was 61.66-107.40%. Further studies are warranted to confirm the results. Copyright © 2017 John Wiley & Sons, Ltd.

  6. Determination of six phthalates in polypropylene consumer products by sonication-assisted extraction/ GC-MS methods

    International Nuclear Information System (INIS)

    Wei, Chong Kian; Fung, Loke Chui; Pang, Michelle

    2011-01-01

    Studies on determination of six kinds of phthalates, for example dimethyl phthalate (DMP), diethyl phthalate (DEP), dibutyl phthalate (DBP), benzyl butyl phthalate (BBP), di-(2-ethylhexyl) phthalate (DEHP), and di-n-octyl phthalate (DnOP), in three kinds of plastic containers for food use, including food container, instant noodle cup and snack container, by gas chromatography in combination with mass spectrometry detector (GC-MS) in electronic ionization mode with selected-ion monitoring (SIM) acquisition method (GC-MS(EI-SIM)) have been carried out. Extraction, clean-up and analysis methods have been developed and optimized. Determination of samples were performed after sonication-assisted extraction with 1:9 toluene and dichloromethane, clean-up with Bio-Beads S-X8 gel-permeation column and analyzed by GC-MS methods. The characteristic ions, 163, 194 for DMP; 149, 177, 222 for DEP; 149, 233, 251 for DBP; 91, 149, 206 for BBP; 149, 176, 193 for DEHP; 149, 167, 279 for DNOP were chosen for quantitative studies. These techniques are possible to detect phthalates at the level of 1-70 mg/ kg. The overall recoveries were 79.2-91.1 % with relative standard deviation (R.S.D.) values at 3.1-11.3 %. Only DEHP was detected in the studied samples. (author)

  7. Quantification of RNA in bacteriophage MS2-like viruses in solution by small-angle X-ray scattering

    International Nuclear Information System (INIS)

    Kuzmanovic, Deborah A.; Elashvili, Ilya; Wick, Charles; O'Connell, Catherine; Krueger, Susan

    2006-01-01

    Recombinant forms of bacteriophage MS2 virus particles, wild-type MS2 and MS2 capsids have been examined in solution using small-angle X-ray scattering (SAXS). SAXS was used to determine the overall size of the virus particles and to quantify the amount of encapsulated viral RNA. These studies show that analysis of natural and recombinant forms of MS2 virus by SAXS can be used as both a quantitative measure of nucleic acid content in situ and diagnostic indicator of sample integrity

  8. A Validated, Rapid HPLC-ESI-MS/MS Method for the Determination of Lycopsamine.

    Science.gov (United States)

    Jedlinszki, Nikoletta; Csupor, Dezső

    2015-07-01

    The aim of the present work was to develop and validate an HPLC-MS/MS method for the determination of a major pyrrolizidine alkaloid of comfrey (lycopsamine) in aqueous samples as a basis for the development of a method for the determination of absorption of lycopsamine by human skin. A linear calibration curve was established in the range of 1.32-440 ng. The intraday precision during the 3-day validation period ranged between 0.57 and 2.48% while the interday precision was 1.70% and 1.95% for quality control samples. LOD was 0.014 ng and recovery was above 97%. The lycopsamine content of the samples stored for 9 and 25 days at 22 degrees C, 10 degrees C and -25 degrees C did not vary. These results underline the good repeatability and accuracy of our method and allow the analysis of samples with very low lycopsamine content.

  9. Development of an Advanced HPLC–MS/MS Method for the Determination of Carotenoids and Fat-Soluble Vitamins in Human Plasma

    Directory of Open Access Journals (Sweden)

    Barbora Hrvolová

    2016-10-01

    Full Text Available The concentration of carotenoids and fat-soluble vitamins in human plasma may play a significant role in numerous chronic diseases such as age-related macular degeneration and some types of cancer. Although these compounds are of utmost interest for human health, methods for their simultaneous determination are scarce. A new high pressure liquid chromatography (HPLC-tandem mass spectrometry (MS/MS method for the quantification of selected carotenoids and fat-soluble vitamins in human plasma was developed, validated, and then applied in a pilot dietary intervention study with healthy volunteers. In 50 min, 16 analytes were separated with an excellent resolution and suitable MS signal intensity. The proposed HPLC–MS/MS method led to improvements in the limits of detection (LOD and quantification (LOQ for all analyzed compounds compared to the most often used HPLC–DAD methods, in some cases being more than 100-fold lower. LOD values were between 0.001 and 0.422 µg/mL and LOQ values ranged from 0.003 to 1.406 µg/mL, according to the analyte. The accuracy, precision, and stability met with the acceptance criteria of the AOAC (Association of Official Analytical Chemists International. According to these results, the described HPLC-MS/MS method is adequately sensitive, repeatable and suitable for the large-scale analysis of compounds in biological fluids.

  10. Development of an Advanced HPLC–MS/MS Method for the Determination of Carotenoids and Fat-Soluble Vitamins in Human Plasma

    Science.gov (United States)

    Hrvolová, Barbora; Martínez-Huélamo, Miriam; Colmán-Martínez, Mariel; Hurtado-Barroso, Sara; Lamuela-Raventós, Rosa Maria; Kalina, Jiří

    2016-01-01

    The concentration of carotenoids and fat-soluble vitamins in human plasma may play a significant role in numerous chronic diseases such as age-related macular degeneration and some types of cancer. Although these compounds are of utmost interest for human health, methods for their simultaneous determination are scarce. A new high pressure liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) method for the quantification of selected carotenoids and fat-soluble vitamins in human plasma was developed, validated, and then applied in a pilot dietary intervention study with healthy volunteers. In 50 min, 16 analytes were separated with an excellent resolution and suitable MS signal intensity. The proposed HPLC–MS/MS method led to improvements in the limits of detection (LOD) and quantification (LOQ) for all analyzed compounds compared to the most often used HPLC–DAD methods, in some cases being more than 100-fold lower. LOD values were between 0.001 and 0.422 µg/mL and LOQ values ranged from 0.003 to 1.406 µg/mL, according to the analyte. The accuracy, precision, and stability met with the acceptance criteria of the AOAC (Association of Official Analytical Chemists) International. According to these results, the described HPLC-MS/MS method is adequately sensitive, repeatable and suitable for the large-scale analysis of compounds in biological fluids. PMID:27754400

  11. A New Method to Quantify Ifosfamide Blood Levels Using Dried Blood Spots and UPLC-MS/MS in Paediatric Patients with Embryonic Solid Tumours.

    Directory of Open Access Journals (Sweden)

    Luz-María Torres

    Full Text Available Ifosfamide blood concentrations are necessary to monitor its therapeutic response, avoiding any adverse effect. We developed and validated an analytical method by UPLC-MS/MS to quantify ifosfamide in dried blood spots (DBS. Blood samples were collected on Whatman 903® filter paper cards. Five 3 mm disks were punched out from each dried blood spot. Acetonitrile and ethyl acetate were used for drug extraction. Chromatographic separation was carried out in an Acquity UPLC equipment with a BEH-C18 column, 2.1 x 100 mm, 1.7 μm (Waters®. The mobile phase consisted in 5 mM ammonium formate and methanol:acetonitrile (40:48:12 v/v/v at 0.2 mL/min. LC-MS/MS detection was done by ESI+ and multiple reaction mode monitoring, ionic transitions were m/z1+ 260.99 > 91.63 for ifosfamide and 261.00 > 139.90 for cyclophosphamide (internal standard. This method was linear within a 100-10000 ng/mL range and it was accurate, precise and selective. Ifosfamide samples in DBS were stable for up to 52 days at -80°C. The procedure was tested in 14 patients, ages 1 month to 17 years (9 males and 5 females, with embryonic tumours treated with ifosfamide, alone or combined, at a public tertiary referral hospital. Ifosfamide blood levels ranged from 11.1 to 39.7 μmol/L at 12 hours after the last infusion, while 24-hour levels ranged from 0.7-19.7 μmol/L. The median at 12 hours was 19.5 μmol/L (Q25 14.4-Q75 29.0 and 3.8 μmol/L (Q25 1.5-Q75 9.9 at 24 hours, p<0.001. This method is feasible to determine ifosfamide plasma levels in paediatric patients.

  12. Novel methods for measuring afterglow in developmental scintillators for X-ray and neutron detection

    Science.gov (United States)

    Bartle, C. M.; Edgar, A.; Dixie, L.; Varoy, C.; Piltz, R.; Buchanan, S.; Rutherford, K.

    2011-09-01

    In this paper we discuss two novel methods of measuring afterglow in scintillators. One method is designed for X-ray detection and the other for neutron detection applications. In the first method a commercial fan-beam scanner of basic design similar to those seen at airports is used to deliver a typically 12 ms long X-ray pulse to a scintillator by passing the test equipment through the scanner on the conveyor belt. In the second method the thermal neutron beam from a research reactor is incident on the scintillator. The beam is cut-off in about 1 ms using a 10B impregnated aluminum pneumatic shutter, and the afterglow is recorded on a dual range storage oscilloscope to capture both the steady state intensity and the weak decay. We describe these measurement methods and the results obtained for a range of developmental ceramic and glass scintillators, as well as some standard scintillators such as NaI(Tl), LiI(Eu) and the plastic scintillator NE102A. Preliminary modeling of the afterglow is presented.

  13. Novel methods for measuring afterglow in developmental scintillators for X-ray and neutron detection

    Energy Technology Data Exchange (ETDEWEB)

    Bartle, C.M., E-mail: m.bartle@gns.cri.nz [National Isotope Centre, GNS Science, PO Box 31312, Lower Hutt 5040 (New Zealand); Edgar, A.; Dixie, L.; Varoy, C. [School of Chemistry and Physics, Victoria University of Wellington, Wellington 6140 (New Zealand); Piltz, R. [Bragg Institute, ANSTO, PMB 1, Menai NSW 2234 (Australia); Buchanan, S.; Rutherford, K. [School of Chemistry and Physics, Victoria University of Wellington, Wellington 6140 (New Zealand)

    2011-09-21

    In this paper we discuss two novel methods of measuring afterglow in scintillators. One method is designed for X-ray detection and the other for neutron detection applications. In the first method a commercial fan-beam scanner of basic design similar to those seen at airports is used to deliver a typically 12 ms long X-ray pulse to a scintillator by passing the test equipment through the scanner on the conveyor belt. In the second method the thermal neutron beam from a research reactor is incident on the scintillator. The beam is cut-off in about 1 ms using a {sup 10}B impregnated aluminum pneumatic shutter, and the afterglow is recorded on a dual range storage oscilloscope to capture both the steady state intensity and the weak decay. We describe these measurement methods and the results obtained for a range of developmental ceramic and glass scintillators, as well as some standard scintillators such as NaI(Tl), LiI(Eu) and the plastic scintillator NE102A. Preliminary modeling of the afterglow is presented.

  14. High throughput LC-MS/MS method for the simultaneous analysis of multiple vitamin D analytes in serum.

    Science.gov (United States)

    Jenkinson, Carl; Taylor, Angela E; Hassan-Smith, Zaki K; Adams, John S; Stewart, Paul M; Hewison, Martin; Keevil, Brian G

    2016-03-01

    Recent studies suggest that vitamin D-deficiency is linked to increased risk of common human health problems. To define vitamin D 'status' most routine analytical methods quantify one particular vitamin D metabolite, 25-hydroxyvitamin D3 (25OHD3). However, vitamin D is characterized by complex metabolic pathways, and simultaneous measurement of multiple vitamin D metabolites may provide a more accurate interpretation of vitamin D status. To address this we developed a high-throughput liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to analyse multiple vitamin D analytes, with particular emphasis on the separation of epimer metabolites. A supportive liquid-liquid extraction (SLE) and LC-MS/MS method was developed to quantify 10 vitamin D metabolites as well as separation of an interfering 7α-hydroxy-4-cholesten-3-one (7αC4) isobar (precursor of bile acid), and validated by analysis of human serum samples. In a cohort of 116 healthy subjects, circulating concentrations of 25-hydroxyvitamin D3 (25OHD3), 3-epi-25-hydroxyvitamin D3 (3-epi-25OHD3), 24,25-dihydroxyvitamin D3 (24R,25(OH)2D3), 1,25-dihydroxyvitamin D3 (1α,25(OH)2D3), and 25-hydroxyvitamin D2 (25OHD2) were quantifiable using 220μL of serum, with 25OHD3 and 24R,25(OH)2D3 showing significant seasonal variations. This high-throughput LC-MS/MS method provides a novel strategy for assessing the impact of vitamin D on human health and disease. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Development and validation of analytical method for Naftopidil in human plasma by LC–MS/MS

    Directory of Open Access Journals (Sweden)

    Pritam S. Jain

    2015-09-01

    Full Text Available A highly sensitive and simple high-performance liquid chromatographic–tandem mass spectrometric (LC–MS-MS assay is developed and validated for the quantification of Naftopidil in human plasma. Naftopidil is extracted from human plasma by methyl tertiary butyl ether and analyzed using a reversed-phase gradient elution on a discovery C 18 5 μ (50 × 4.6 column. A methanol: 2 mM ammonium formate (90:10 as mobile phase, is used and detection was performed by MS using electrospray ionization in positive mode. Propranolol is used as the internal standard. The lower limits of quantification are 0.495 ng/mL. The calibration curves are linear over the concentration range of 0.495–200.577 ng/mL of plasma for each analyte. This novel LC–MS-MS method shows satisfactory accuracy and precision and is sufficiently sensitive for the performance of pharmacokinetic studies in humans.

  16. siMS Score: Simple Method for Quantifying Metabolic Syndrome.

    Science.gov (United States)

    Soldatovic, Ivan; Vukovic, Rade; Culafic, Djordje; Gajic, Milan; Dimitrijevic-Sreckovic, Vesna

    2016-01-01

    To evaluate siMS score and siMS risk score, novel continuous metabolic syndrome scores as methods for quantification of metabolic status and risk. Developed siMS score was calculated using formula: siMS score = 2*Waist/Height + Gly/5.6 + Tg/1.7 + TAsystolic/130-HDL/1.02 or 1.28 (for male or female subjects, respectively). siMS risk score was calculated using formula: siMS risk score = siMS score * age/45 or 50 (for male or female subjects, respectively) * family history of cardio/cerebro-vascular events (event = 1.2, no event = 1). A sample of 528 obese and non-obese participants was used to validate siMS score and siMS risk score. Scores calculated as sum of z-scores (each component of metabolic syndrome regressed with age and gender) and sum of scores derived from principal component analysis (PCA) were used for evaluation of siMS score. Variants were made by replacing glucose with HOMA in calculations. Framingham score was used for evaluation of siMS risk score. Correlation between siMS score with sum of z-scores and weighted sum of factors of PCA was high (r = 0.866 and r = 0.822, respectively). Correlation between siMS risk score and log transformed Framingham score was medium to high for age groups 18+,30+ and 35+ (0.835, 0.707 and 0.667, respectively). siMS score and siMS risk score showed high correlation with more complex scores. Demonstrated accuracy together with superior simplicity and the ability to evaluate and follow-up individual patients makes siMS and siMS risk scores very convenient for use in clinical practice and research as well.

  17. What Is in Your Wallet? Quantitation of Drugs of Abuse on Paper Currency with a Rapid LC-MS/MS Method

    Science.gov (United States)

    Parker, Patrick D.; Beers, Brandon; Vergne, Matthew J.

    2017-01-01

    Laboratory experiments were developed to introduce students to the quantitation of drugs of abuse by high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). Undergraduate students were introduced to internal standard quantitation and the LC-MS/MS method optimization for cocaine. Cocaine extracted from paper currency was…

  18. LC-ESI/MS/MS method for rapid screening and confirmation of 44 exogenous anabolic steroids in human urine.

    Science.gov (United States)

    Jeon, Byoung Wook; Yoo, Hye Hyun; Jeong, Eun Sook; Kim, Ho Jun; Jin, Changbae; Kim, Dong Hyun; Lee, Jaeick

    2011-09-01

    A sensitive and rapid method based on liquid chromatography-triple-quadrupole tandem mass spectrometry (LC-MS/MS) with electrospray ionization (ESI) has been developed and validated for the screening and confirmation of 44 exogenous anabolic steroids (29 parent steroids and 15 metabolites) in human urine. The method involves an enzymatic hydrolysis, liquid-liquid extraction, and detection by LC-MS/MS. A triple-quadrupole mass spectrometer was operated in positive ESI mode with selected reaction monitoring (SRM) mode for the screening and product ion scan mode for the confirmation. The protonated molecular ions were used as precursor ions for the SRM analysis and product ion scan. The intraday and interday precisions of the target analytes at concentrations of the minimum required performance levels for the screening were 2-14% and 2-15%, respectively. The limits of detection for the screening and confirmation method were 0.1-10 ng/mL and 0.2-10 ng/mL, respectively, for 44 steroids. This method was successfully applied to analysis of urine samples from suspected anabolic steroid abusers.

  19. Isoelectric point is an inadequate descriptor of MS2, Phi X 174 and PRD1 phages adhesion on abiotic surfaces.

    Science.gov (United States)

    Dika, Christelle; Duval, Jérôme F L; Francius, Gregory; Perrin, Aline; Gantzer, Christophe

    2015-05-15

    MS2, Phi X 174 and PRD1 bacteriophages are commonly used as surrogates to evaluate pathogenic virus behavior in natural aquatic media. The interfacial properties of these model soft bioparticles are herein discussed in connection with their propensities to adhere onto abiotic surfaces that differ in terms of surface charges and hydrophobicities. The phages considered in this work exhibit distinct multilayered surface structures and their electrostatic charges are evaluated from the dependence of their electrophoretic mobilities on electrolyte concentration at neutral pH on the basis of electrokinetic theory for soft (bio)particles. The charges of the viruses probed by electrokinetics vary according to the sequence Phi X 174⩽PRD1≪MS2, where 'Phi X 174≪MS2Phi X 174 and PRD1 bacteriophages. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. METHOD 544. DETERMINATION OF MICROCYSTINS AND NODULARIN IN DRINKING WATER BY SOLID PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/TANDEM MASS SPECTROMETRY (LC/MS/MS)

    Science.gov (United States)

    Method 544 is an accurate and precise analytical method to determine six microcystins (including MC-LR) and nodularin in drinking water using solid phase extraction and liquid chromatography tandem mass spectrometry (SPE-LC/MS/MS). The advantage of this SPE-LC/MS/MS is its sensi...

  1. Analytical Method Details (MS): SE52_MS01 [Metabolonote[Archive

    Lifescience Database Archive (English)

    Full Text Available stem and Waters Q-Tof Premier UPLC-QTOF-MS ESI Negative The eluates (3 μl) were subsequently subjected to metabolome...DS column (LC-ESI-Q-Tof/MS, HPLC: Waters Acquity UPLC system; MS: Waters Q-Tof Premier). The metabolome...d (Matsuda et al., 2009c, 2010a). Briefly, the metabolome data were obtained in the negative ion mode (m/z 1... the complex nature of the metabolome data. To construct MS2T libraries, the extracts of five ecotypes were

  2. Inductively coupled plasma – Tandem mass spectrometry (ICP-MS/MS): A powerful and universal tool for the interference-free determination of (ultra)trace elements – A tutorial review

    Energy Technology Data Exchange (ETDEWEB)

    Balcaen, Lieve; Bolea-Fernandez, Eduardo [Ghent University, Department of Analytical Chemistry, Krijgslaan 281-S12, B-9000 Ghent (Belgium); Resano, Martín [University of Zaragoza, Department of Analytical Chemistry, Pedro Cerbuna 12, E-50009 Zaragoza (Spain); Vanhaecke, Frank, E-mail: Frank.Vanhaecke@UGent.be [Ghent University, Department of Analytical Chemistry, Krijgslaan 281-S12, B-9000 Ghent (Belgium)

    2015-09-24

    This paper is intended as a tutorial review on the use of inductively coupled plasma – tandem mass spectrometry (ICP-MS/MS) for the interference-free quantitative determination and isotope ratio analysis of metals and metalloids in different sample types. Attention is devoted both to the instrumentation and to some specific tools and procedures available for advanced method development. Next to the more typical reaction gases, e.g., H{sub 2}, O{sub 2} and NH{sub 3}, also the use of promising alternative gases, such as CH{sub 3}F, is covered, and the possible reaction pathways with those reactive gases are discussed. A variety of published applications relying on the use of ICP-MS/MS are described, to illustrate the added value of tandem mass spectrometry in (ultra)trace analysis. - Highlights: • First review on tandem ICP-mass spectrometry (ICP-MS/MS). • Clear description of operating principles of ICP-MS/MS. • Description on how to make use of product ion scans, precursor ion scans and neutral gain scans in method development. • Overview of applications published so far.

  3. Inductively coupled plasma – Tandem mass spectrometry (ICP-MS/MS): A powerful and universal tool for the interference-free determination of (ultra)trace elements – A tutorial review

    International Nuclear Information System (INIS)

    Balcaen, Lieve; Bolea-Fernandez, Eduardo; Resano, Martín; Vanhaecke, Frank

    2015-01-01

    This paper is intended as a tutorial review on the use of inductively coupled plasma – tandem mass spectrometry (ICP-MS/MS) for the interference-free quantitative determination and isotope ratio analysis of metals and metalloids in different sample types. Attention is devoted both to the instrumentation and to some specific tools and procedures available for advanced method development. Next to the more typical reaction gases, e.g., H_2, O_2 and NH_3, also the use of promising alternative gases, such as CH_3F, is covered, and the possible reaction pathways with those reactive gases are discussed. A variety of published applications relying on the use of ICP-MS/MS are described, to illustrate the added value of tandem mass spectrometry in (ultra)trace analysis. - Highlights: • First review on tandem ICP-mass spectrometry (ICP-MS/MS). • Clear description of operating principles of ICP-MS/MS. • Description on how to make use of product ion scans, precursor ion scans and neutral gain scans in method development. • Overview of applications published so far.

  4. Method Development and Validation for UHPLC-MS-MS Determination of Hop Prenylflavonoids in Human Serum

    OpenAIRE

    Yuan, Yang; Qiu, Xi; Nikolic, Dejan; Dahl, Jeffrey H.; van Breemen, Richard B.

    2012-01-01

    Hops (Humulus lupulus L.) are used in the brewing of beer, and hop extracts containing prenylated compounds such as xanthohumol and 8-prenylnaringenin are under investigation as dietary supplements for cancer chemoprevention and for the management of hot flashes in menopausal women. To facilitate clinical studies of hop safety and efficacy, a selective, sensitive, and fast ultra-high pressure liquid chromatography tandem mass spectrometry (UHPLC-MS-MS) method was developed and validated for t...

  5. Simultaneous quantification of ten constituents of Xanthoceras sorbifolia Bunge using UHPLC-MS methods and evaluation of their radical scavenging, DNA scission protective, and α-glucosidase inhibitory activities.

    Science.gov (United States)

    Zhang, Yu; Ma, Jian-Nan; Ma, Chun-Li; Qi, Zhi; Ma, Chao-Mei

    2015-11-01

    The present study was designed to investigate the bioactive constituents of Xanthoceras sorbifolia in terms of amounts and their antioxidant, DNA scission protection, and α-glucosidase inhibitory activities. Simultaneous quantification of 10 X. sorbifolia constituents was carried out by a newly established ultra-high performance liquid chromatography-quadrupole mass spectrometry method (UHPLC-MS). The antioxidant activities were evaluated by measuring DPPH radical scavenging and DNA scission protective activities. The α-glucosidase inhibitory activities were investigated by using an assay with α-glucosidase from Bacillus Stearothermophilus and disaccharidases from mouse intestine. We found that the wood of X. sorbifolia was rich in phenolic compounds with the contents of catechin, epicatechin, myricetin, and dihydromyricetin being 0.12-0.19, 1.94-2.16, 0.77-0.91, and 6.76-7.89 mg·g(-1), respectively. The four constituents strongly scavenged DPPH radicals (with EC50 being 4.2, 3.8 and 5.7 μg·mL(-1), respectively) and remarkably protected peroxyl radical-induced DNA strand scission (92.10%, 94.66%, 75.44% and 89.95% of protection, respectively, at a concentration of 10 μmol·L(-1)). A dimeric flavan 3-ol, epigallocatechin-(4β→8, 2β→O-7)-epicatechin potently inhibited α-glucosidase with an IC50 value being as low as 1.2 μg·mL(-1). The established UHPLC-MS method could serve as a quality control tool for X. sorbifolia. In conclusion, the high contents of antioxidant and α-glucosidase inhibitory constituents in X. sorbifolia support its use as complementation of other therapeutic agents for metabolic disorders, such as diabetes and hypertension. Copyright © 2015 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.

  6. {sup 99}Tc bioassay by inductively coupled plasma mass spectrometry (ICP-MS)

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, L.A.

    1998-05-01

    A means of analyzing {sup 99}Tc in urine by inductively coupled plasma mass spectrometry (ICP-MS) has been developed. Historically, {sup 99}Tc analysis was based on the radiometric detection of the 293 keV E{sub Max} beta decay product by liquid scintillation or gas flow proportional counting. In a urine matrix, the analysis of{sup 99}Tc is plagued with many difficulties using conventional radiometric methods. Difficulties originate during chemical separation due to the volatile nature of Tc{sub 2}O{sub 7} or during radiation detection due to color or chemical quenching. A separation scheme for {sup 99}Tc detection by ICP-MS is given and is proven to be a sensitive and robust analytical alternative. A comparison of methods using radiometric and mass quantitation of {sup 99}Tc has been conducted in water, artificial urine, and real urine matrices at activity levels between 700 and 2,200 dpm/L. Liquid scintillation results based on an external standard quench correction and a quench curve correction method are compared to results obtained by ICP-MS. Each method produced accurate results, however the precision of the ICP-MS results is superior to that of liquid scintillation results. Limits of detection (LOD) for ICP-MS and liquid scintillation detection are 14.67 and 203.4 dpm/L, respectively, in a real urine matrix. In order to determine the basis for the increased precision of the ICP-MS results, the detection sensitivity for each method is derived and measured. The detection sensitivity for the {sup 99}Tc isotope by ICP-MS is 2.175 x 10{sup {minus}7} {+-} 8.990 x 10{sup {minus}9} and by liquid scintillation is 7.434 x 10{sup {minus}14} {+-} 7.461 x 10{sup {minus}15}. A difference by seven orders of magnitude between the two detection systems allows ICP-MS samples to be analyzed for a period of 15 s compared to 3,600 s by liquid scintillation counting with a lower LOD.

  7. Systematic Assessment of Seven Solvent and Solid-Phase Extraction Methods for Metabolomics Analysis of Human Plasma by LC-MS

    Science.gov (United States)

    Sitnikov, Dmitri G.; Monnin, Cian S.; Vuckovic, Dajana

    2016-12-01

    The comparison of extraction methods for global metabolomics is usually executed in biofluids only and focuses on metabolite coverage and method repeatability. This limits our detailed understanding of extraction parameters such as recovery and matrix effects and prevents side-by-side comparison of different sample preparation strategies. To address this gap in knowledge, seven solvent-based and solid-phase extraction methods were systematically evaluated using standard analytes spiked into both buffer and human plasma. We compared recovery, coverage, repeatability, matrix effects, selectivity and orthogonality of all methods tested for non-lipid metabolome in combination with reversed-phased and mixed-mode liquid chromatography mass spectrometry analysis (LC-MS). Our results confirmed wide selectivity and excellent precision of solvent precipitations, but revealed their high susceptibility to matrix effects. The use of all seven methods showed high overlap and redundancy which resulted in metabolite coverage increases of 34-80% depending on LC-MS method employed as compared to the best single extraction protocol (methanol/ethanol precipitation) despite 7x increase in MS analysis time and sample consumption. The most orthogonal methods to methanol-based precipitation were ion-exchange solid-phase extraction and liquid-liquid extraction using methyl-tertbutyl ether. Our results help facilitate rational design and selection of sample preparation methods and internal standards for global metabolomics.

  8. A sensitive LC-MS/MS method for measurement of organophosphorus pesticides and their oxygen analogs in air sampling matrices.

    Science.gov (United States)

    Armstrong, Jenna L; Dills, Russell L; Yu, Jianbo; Yost, Michael G; Fenske, Richard A

    2014-01-01

    A rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method has been developed for determination of levels of the organophosphorus (OP) pesticides chlorpyrifos (CPF), azinphos methyl (AZM), and their oxygen analogs chlorpyrifos-oxon (CPF-O) and azinphos methyl-oxon (AZM-O) on common active air sampling matrices. XAD-2 resin and polyurethane foam (PUF) matrices were extracted with acetonitrile containing stable-isotope labeled internal standards (ISTD). Analysis was accomplished in Multiple Reaction Monitoring (MRM) mode, and analytes in unknown samples were identified by retention time (±0.1 min) and qualifier ratio (±30% absolute) as compared to the mean of calibrants. For all compounds, calibration linearity correlation coefficients were ≥0.996. Limits of detection (LOD) ranged from 0.15-1.1 ng/sample for CPF, CPF-O, AZM, and AZM-O on active sampling matrices. Spiked fortification recoveries were 78-113% from XAD-2 active air sampling tubes and 71-108% from PUF active air sampling tubes. Storage stability tests also yielded recoveries ranging from 74-94% after time periods ranging from 2-10 months. The results demonstrate that LC-MS/MS is a sensitive method for determining these compounds from two different matrices at the low concentrations that can result from spray drift and long range transport in non-target areas following agricultural applications. In an inter-laboratory comparison, the limit of quantification (LOQ) for LC-MS/MS was 100 times lower than a typical gas chromatography-mass spectrometry (GC-MS) method.

  9. Determination of Dextromethorphan in Oral Fluid by LC-MS-MS.

    Science.gov (United States)

    Amaratunga, Piyadarsha; Clothier, Morgan; Lorenz Lemberg, Bridget; Lemberg, Dave

    2016-06-01

    Dextromethorphan (DXM) is an antitussive drug found in commonly used nonprescription cold and cough medications. At low doses, DXM is a safe drug that does not produce adverse reactions. However, abuse of DXM has been reported among adolescents and young adults using the drug at higher doses. DXM is not a scheduled drug in the USA, and the primary reason for its abuse is the ease of availability. DXM is available to purchase in the form of over-the-counter cough medications, such as Robitussin(®) and Coricidin(®), or it can be purchased over the Internet in the form of a powder. In this research work, we developed an LC-MS-MS method that can quantify DXM and dextrorphan (DXO) in oral fluid in a high-throughput toxicology laboratory setting. The developed method was validated according to the Scientific Working Group for Forensic Toxicology guidelines. The linear dynamic range was 5-100 ng/mL with a lowest limit of quantitation (LLOQ) of 5.0 ng/mL for DXM and DXO. Overall, the results of the accuracy and the precision values were within the acceptance criteria for both drugs. In addition, selectivity, matrix effect and recovery were calculated for the LC-MS-MS method. Authentic samples (n = 59) were tested to evaluate the applicability of the method. Thirty samples were found to be positive for DXM and DXO and two samples were found to be positive for DXM only. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Økologisk risikovurdering af de genmodificerede raps MS8, RF3 og MS8xRF3 i anmeldelse til markedsføring under Forordning 1829/2003/EF

    DEFF Research Database (Denmark)

    Kjellsson, Gøsta; Sørensen, Jesper Givskov; Strandberg, Morten Tune

    2012-01-01

    transportruterne. Kommentarer til EFSA: D.11.3 and D.11.4: Because there is a risk of accidental dispersal and possible adventitious presence of Ms8, Rf3 and Ms8xRf3-oilseed rape at import areas and along transport routes, these areas should be monitored for GM oilseed rape-plants from seed-spill. Furthermore GM...

  11. Økologisk risikovurdering af de genmodificerede raps MS8, RF3 og MS8xRF3 i anmeldelse til markedsføring under Forordning 1829/2003/EF

    DEFF Research Database (Denmark)

    Kjellsson, Gøsta; Strandberg, Morten Tune; Sørensen, Jesper Givskov

    2011-01-01

    transportruterne. Kommentarer til EFSA: D.11.3 and D.11.4: Because there is a risk of accidental dispersal and possible adventitious presence of Ms8, Rf3 and Ms8xRf3-oilseed rape at import areas and along transport routes, these areas should be monitored for GM oilseed rape-plants from seed-spill. Furthermore GM...

  12. A method for the determination of acrylamide in bakery products using ion trap LC-ESI-MS/MS.

    Science.gov (United States)

    Claus, Achim; Weisz, Georg M; Kammerer, Dietmar R; Carle, Reinhold; Schieber, Andreas

    2005-10-01

    Acrylamide levels of bakery products, e. g., bread and bread rolls, are usually below 100 microg/kg , often even below 50 microg/kg. Therefore, usual analytical methods which have an LOQ greater, not dbl equals 25 microg/kg are not sensitive enough for detailed investigations on acrylamide formation within these commodities. An improved method for trace level determination of acrylamide in bakery products was developed using ion trap LC-ESI-MS/MS. Samples were divided into crumbs and crusts to achieve an initial concentration by removing the crumbs since these are devoid of acrylamide. After sample extraction and clean-up using multimode SPE cartridges, further analyte enrichment was accomplished by solid-phase-supported liquid-liquid extraction with ethyl acetate prior to LC-MS/MS analysis. The method was evaluated using bread, bread rolls, alkali-baked bread rolls, and toast. LOQ was calculated from the confidence interval of the calibration curve and found to be 1.7 ng/mL, corresponding to 17 microg/kg of product. When crumbs and crusts were separated, an LOQ of 10.2 microg/kg of bakery product could be obtained. As demonstrated in preliminary comparative analyses, accuracy of the method met the requirements for determination of trace level acrylamide formation in bakery products. Mean recovery was 102.4% (CV 4.5%), intermediate reproducibility revealed a CV of 2.1%, and a repeatability of CV 6.0%.

  13. Development of on-line electrochemical sample pretreatment methods for the analysis of thallium and uranium by ICP-MS

    International Nuclear Information System (INIS)

    Zhou, F.; Van Berkel, G.J.; Morton, S.J.; Duckworth, D.C.; Adeniyi, W.K.; Keller, J.M.

    1995-01-01

    Anodic and adsorptive stripping voltammetry (AWV and AdSV, respectively) were performed on-line with a mercury thin-film electrode (MTFE) to effect the selective accumulation and detection of thallium and uranium, respectively. ASV-ICP-MS experiments using thallium as the test element were performed to characterize the behavior of the on-line system for low level and quantitative determinations. Excellent linearity in response was demonstrated for thallium standards ranging from 0.25 ng/L to 50 microg/L. The 1.0 pg/L detection limit calculated from this data for thallium (3σ/sensitivity) was 400 times lower than that of conventional ICP-MS. The ability to overcome sample matrix effects in quantitative determinations was demonstrated by the analysis of an undiluted synthetic urine sample. AdSV-ICP-MS experiments were performed using uranium as the test element to demonstrate the utility of this method for the determination of radiologically important elements. A uranium(VI)-cupferron complex was used to effect adsorptive accumulation of uranium from a 10 microg/L standard solution onto the MTFE. The uranium was chemically stripped from the electrode for subsequent downstream detection by the ICP-MS. The quantitative nature of this method and a modest enhancement of signal levels (∼X10) over those levels obtained with conventional ICP-MS for samples in the microgram/liter concentration range were demonstrated. Modifications to the current system to provide low flow rate operation will allow further optimization of the ASV-ICP-MS and AdSV-ICP-MS combinations

  14. Report on the survey of geothermal development at Okushiri Island, Hokkaido. Geochemical survey (GC/MS and MS method); Hokkaido Okushiritou chinetsu kaihatsu chosa chikagaku chosa (GC/MS and MS ho) hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1991-09-01

    To elucidate chemical components of soil gas in the Okushiri Island area, soil gas was collected by the method using charcoal adsorbent, and analysis was made by the GC/MS method. Out of the 19 measuring points, 17 points were set up near the measuring points in the FY 1998 survey by the finger print method. At the same measuring points, analytical survey by the MS method was also conducted to sort the type of soil gas. As a result of the GC/MS analysis, xylene or ethyl benzene was detected at 12 measuring points of all 19 measuring points, and from the distribution, it was predicted that there were anomaly zones in the district along the road of the Okushiri Island line and the district southward from the 5.8K Pass. These results were in harmony with the results of the survey by the finger print method. As to the sorting of soil gas based on the results of the MS analysis, the results were different at 8 measuring points from those of the survey by the finger print method in FY 1998. It was considered that the cause was the accidental vaporization of a large quantity of acetaldehyde, and acetaldehyde was regarded as a noise gas component that does not reflect the geothermal structure. (NEDO)

  15. Direct identification of microorganisms from positive blood cultures by MALDI-TOF MS using an in-house saponin method.

    Science.gov (United States)

    Yonetani, Shota; Ohnishi, Hiroaki; Ohkusu, Kiyofumi; Matsumoto, Tetsuya; Watanabe, Takashi

    2016-11-01

    Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is a fast and reliable method for the identification of bacteria. A MALDI Sepsityper kit is generally used to prepare samples obtained directly from culture bottles. However, the relatively high cost of this kit is a major obstacle to introducing this method into routine clinical use. In this study, the accuracies of three different preparation methods for rapid direct identification of bacteria from positive blood culture bottles by MALDI-TOF MS analysis were compared. In total, 195 positive bottles were included in this study. Overall, 78.5%, 68.7%, and 76.4% of bacteria were correctly identified to the genus level (score ≥1.7) directly from positive blood cultures using the Sepsityper, centrifugation, and saponin methods, respectively. The identification rates using the Sepsityper and saponin methods were significantly higher than that using the centrifugation method (Sepsityper vs. centrifugation, pdirectly from blood culture bottles, and could be a less expensive alternative to the Sepsityper method. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  16. Analysis of Ba{sub x}Sr{sub y}TiO{sub 3} perovskite layers. II. Development of analytical method for the determination of the stoichiometry and trace impurities by ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Boulyga, S.F. [Forschungszentrum Juelich GmbH (Germany). Zentralabteilung fuer Chemische Analysen]|[Radiation Physics and Chemistry Problems Inst., Minsk (Belarus); Becker, J.S. [Forschungszentrum Juelich GmbH (Germany). Zentralabteilung fuer Chemische Analysen

    2000-11-01

    Determination of stoichiometry in semiconducting and non-conducting thin layers is of importance for the study of growth mechanisms and for the control of defects during their development and production. An analytical procedure for inductively coupled plasma mass spectrometry (ICP-MS) was developed using different ICP-MS instruments [one double-focusing sector field ICP-MS (DF-ICP-MS) and two quadrupole ICP-MS without and with hexapole collision cell (ICP-QMS and HEX-ICP-QMS, respectively)] for the determination of stoichiometry and trace impurities in thin Ba{sub x}Sr{sub y}TiO{sub 3} (BST) perovskite layers on silicon substrates after dissolution of layer. Maximum sensitivity, lowest detection limits and best precision was achieved in DF-ICP-MS. ICP-QMS with hexapole collision cell yielded better sensitivity and lower limits of detection in comparison to conventional quadrupole ICP-MS. (orig.)

  17. Development and Validation of a LC/MS/MS Method for the Determination of Duloxetine in Human Plasma and Its Application to Pharmacokinetic Study

    Directory of Open Access Journals (Sweden)

    D. Chandrapal Reddy

    2012-01-01

    Full Text Available A selective, high sensitive and high throughput liquid chromatography-tandem mass spectrometry (LC-ESI-MS/MS method has been developed and validated for the chromatographic separation and quantitation of duloxetine in human EDTA plasma using fluoxetine (IS as an internal standard. Analyte and IS were extracted from human plasma by liquid-liquid extraction using MTBE-n Hexane (80:20.The eluted samples were chromatographed on X-terra RP8 (50 mmx4.6 mm, 5 μm particle size column by using mixture of 30 mM ammonium formate (pH-5.0±0.05 and acetonitrile as an isocratic mobile phase at a flow rate of 0.40 mL/min and analyzed by mass spectrometer in the multiple reaction monitoring (MRM using the respective m/z 298.08→154.0 for duloxetine and 310.02→148.07 for IS. The linearity of the response/ concentration curve was established in human plasma over the concentration range 0.100-100.017 ng/mL. The lower detection limit (LOD,S/N>3 was 0.04 ng/mL and the lower limit of quantization (LOQ,S/N>10 was 0.100 ng/mL. This LC-MS/MS method was validated with Intra-batch and Inter-batch precision of 5.21-7.02. The Intra-batch and Inter-batch accuracy was 97.14-103.50 respectively. Recovery of duloxetine in human plasma is 80.31% and ISTD recovery is 81.09%. The main pharmacokinetic parameters were Tmax (hr = (7.25±1.581, Cmax (ng/mL (44.594±18.599, AUC0→t, = (984.702±526.502 and AUC0→∞, (1027.147±572.790 respectively.

  18. Development and full validation of an UPLC-MS/MS method for the quantification of the plant-derived alkaloid indirubin in rat plasma.

    Science.gov (United States)

    Jähne, Evelyn A; Sampath, Chethan; Butterweck, Veronika; Hamburger, Matthias; Oufir, Mouhssin

    2016-09-05

    An UPLC-MS/MS method for the quantification of indirubin in lithium heparinized rat plasma was developed and validated according to current international guidelines. Indirubin was extracted from rat plasma by using Waters Ostro™ pass-through sample preparation plates. The method was validated with a LLOQ of 5.00ng/mL and an ULOQ of 500ng/mL. The calibration curve was fitted by least-square quadratic regression, and a weighting factor of 1/X was applied. Recoveries of indirubin and I.S. were consistent and ≥75.5%. Stability studies demonstrated that indirubin was stable in lithium heparinized rat plasma for at least 3 freeze/thaw cycles, for 3h at RT, for 96h in the autosampler at 10°C, and for 84days when stored below -65°C. Preliminary pharmacokinetic (PK) data were obtained from Sprague Dawley rats after intravenous administration of indirubin (2mg/kg b.w.) and blood sampling up to 12h after injection. PK parameters were determined by non-compartmental analysis. Indirubin had a half-life (t1/2) of 35min, and a relatively high clearance (CL) of 2.71L/h/kg. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. High-Throughput LC-MS/MS Method for Direct Quantification of Glucuronidated, Sulfated and Free Enterolactone in Human Plasma

    DEFF Research Database (Denmark)

    Nørskov, Natalja; Kyrø, Cecilie; Olsen, Anja

    2016-01-01

    Sulfation and glucuronidation constitute a major pathway in humans and may play an important role in biological activity of metabolites including the enterolignan, enterolactone. Because the aromatic structure of enterolactone has similarities to steroid metabolites, it was hypothesized that ente......Sulfation and glucuronidation constitute a major pathway in humans and may play an important role in biological activity of metabolites including the enterolignan, enterolactone. Because the aromatic structure of enterolactone has similarities to steroid metabolites, it was hypothesized......−MS/MS and a fluoroimmunoassay; however, most of these methods measure the total concentration of enterolactone, without any specification of its conjugation pattern. Here for the first time we present a high-throughput LC−MS/MS method to quantify enterolactone in its intact form as glucuronide, sulfate, and free enterolactone....... The method has shown good accuracy and precision at low concentration and very high sensitivity, with LLOQ for enterolactone sulfate at 16 pM, enterolactone glucuronide at 26 pM, and free enterolactone at 86 pM. The short run time of 2.6 min combined with simple sample clean up and high sensitivity make...

  20. An UPLC-MS/MS method for highly sensitive high-throughput analysis of phytohormones in plant tissues

    Directory of Open Access Journals (Sweden)

    Balcke Gerd Ulrich

    2012-11-01

    Full Text Available Abstract Background Phytohormones are the key metabolites participating in the regulation of multiple functions of plant organism. Among them, jasmonates, as well as abscisic and salicylic acids are responsible for triggering and modulating plant reactions targeted against pathogens and herbivores, as well as resistance to abiotic stress (drought, UV-irradiation and mechanical wounding. These factors induce dramatic changes in phytohormone biosynthesis and transport leading to rapid local and systemic stress responses. Understanding of underlying mechanisms is of principle interest for scientists working in various areas of plant biology. However, highly sensitive, precise and high-throughput methods for quantification of these phytohormones in small samples of plant tissues are still missing. Results Here we present an LC-MS/MS method for fast and highly sensitive determination of jasmonates, abscisic and salicylic acids. A single-step sample preparation procedure based on mixed-mode solid phase extraction was efficiently combined with essential improvements in mobile phase composition yielding higher efficiency of chromatographic separation and MS-sensitivity. This strategy resulted in dramatic increase in overall sensitivity, allowing successful determination of phytohormones in small (less than 50 mg of fresh weight tissue samples. The method was completely validated in terms of analyte recovery, sensitivity, linearity and precision. Additionally, it was cross-validated with a well-established GC-MS-based procedure and its applicability to a variety of plant species and organs was verified. Conclusion The method can be applied for the analyses of target phytohormones in small tissue samples obtained from any plant species and/or plant part relying on any commercially available (even less sensitive tandem mass spectrometry instrumentation.

  1. Analytical methods for multiresidue determination of sulfonamides and trimethoprim in meat and ground water samples by CE-MS and CE-MS/MS.

    Science.gov (United States)

    Soto-Chinchilla, Jorge J; García-Campaña, Ana M; Gámiz-Gracia, Laura

    2007-11-01

    This paper presents two methods based on CZE-MS detection and CZE-MS/MS detection developed for the multiresidue determination of ten sulfonamides (sulfapyridine, sulfadoxin, sulfamethazine, sulfadimethoxine, sulfameter, sulfamerazine, sulfachlorpyridazine, sulfadiazine, sulfamethoxazole, and sulfamethizole) and a potentiator, trimethoprim (TMP), whose contents are regulated by the EU Council Regulation no. 2377/90 in animal edible tissues. Experimental designs were employed to optimize the electrospray conditions. MS/MS experiments using an IT as analyzer operating in multiple reaction monitoring (MRM) mode were carried out to achieve the minimum number of points according to the 2002/657/EC European Decision for unambiguous identification. The proposed procedures have been compared in terms of the performance characteristics and trueness. The limits of detection and quantification were in all cases lower than the maximum residue limits legislated for these compounds and the recoveries were satisfactory, being possible the application for their monitoring in foodstuff of animal origin and in environmental samples, allowing the determination of sulfonamides and TMP residues in meat and in superficial water in the low microg/L range.

  2. Analytical Method Details (MS): SE53_MS03 [Metabolonote[Archive

    Lifescience Database Archive (English)

    Full Text Available SE53_MS03 CE-TOF/MS Agilent CE capillary electrophoresis system,Agilent G3250AA LC/...s were performed using an Agilent CE capillary electrophoresis system (Agilent Technologies, Waldbronn, Germ

  3. LA-ICP-MS of magnetite: Methods and reference materials

    Science.gov (United States)

    Nadoll, P.; Koenig, A.E.

    2011-01-01

    Magnetite (Fe3O4) is a common accessory mineral in many geologic settings. Its variable geochemistry makes it a powerful petrogenetic indicator. Electron microprobe (EMPA) analyses are commonly used to examine major and minor element contents in magnetite. Laser ablation ICP-MS (LA-ICP-MS) is applicable to trace element analyses of magnetite but has not been widely employed to examine compositional variations. We tested the applicability of the NIST SRM 610, the USGS GSE-1G, and the NIST SRM 2782 reference materials (RMs) as external standards and developed a reliable method for LA-ICP-MS analysis of magnetite. LA-ICP-MS analyses were carried out on well characterized magnetite samples with a 193 nm, Excimer, ArF LA system. Although matrix-matched RMs are sometimes important for calibration and normalization of LA-ICP-MS data, we demonstrate that glass RMs can produce accurate results for LA-ICP-MS analyses of magnetite. Cross-comparison between the NIST SRM 610 and USGS GSE-1G indicates good agreement for magnetite minor and trace element data calibrated with either of these RMs. Many elements show a sufficiently good match between the LA-ICP-MS and the EMPA data; for example, Ti and V show a close to linear relationship with correlation coefficients, R2 of 0.79 and 0.85 respectively. ?? 2011 The Royal Society of Chemistry.

  4. Sewage-based epidemiology in monitoring the use of new psychoactive substances: Validation and application of an analytical method using LC-MS/MS.

    Science.gov (United States)

    Kinyua, Juliet; Covaci, Adrian; Maho, Walid; McCall, Ann-Kathrin; Neels, Hugo; van Nuijs, Alexander L N

    2015-09-01

    Sewage-based epidemiology (SBE) employs the analysis of sewage to detect and quantify drug use within a community. While SBE has been applied repeatedly for the estimation of classical illicit drugs, only few studies investigated new psychoactive substances (NPS). These compounds mimic effects of illicit drugs by introducing slight modifications to chemical structures of controlled illicit drugs. We describe the optimization, validation, and application of an analytical method using liquid chromatography coupled to positive electrospray tandem mass spectrometry (LC-ESI-MS/MS) for the determination of seven NPS in sewage: methoxetamine (MXE), butylone, ethylone, methylone, methiopropamine (MPA), 4-methoxymethamphetamine (PMMA), and 4-methoxyamphetamine (PMA). Sample preparation was performed using solid-phase extraction (SPE) with Oasis MCX cartridges. The LC separation was done with a HILIC (150 x 3 mm, 5 µm) column which ensured good resolution of the analytes with a total run time of 19 min. The lower limit of quantification (LLOQ) was between 0.5 and 5 ng/L for all compounds. The method was validated by evaluating the following parameters: sensitivity, selectivity, linearity, accuracy, precision, recoveries and matrix effects. The method was applied on sewage samples collected from sewage treatment plants in Belgium and Switzerland in which all investigated compounds were detected, except MPA and PMA. Furthermore, a consistent presence of MXE has been observed in most of the sewage samples at levels higher than LLOQ. Copyright © 2015 John Wiley & Sons, Ltd.

  5. Multi-mycotoxin stable isotope dilution LC-MS/MS method for Fusarium toxins in beer.

    Science.gov (United States)

    Habler, Katharina; Gotthardt, Marina; Schüler, Jan; Rychlik, Michael

    2017-03-01

    A stable isotope dilution LC-MS/MS multi-mycotoxin method was developed for 12 different Fusarium toxins including modified mycotoxins in beer (deoxynivalenol-3-glucoside, deoxynivalenol, 3-acetyldeoxynivalenol, 15-acetyl-deoxynivalenol, HT2-toxin, T2-toxin, enniatin B, B1, A1, A, beauvericin and zearalenone). As sample preparation and purification of beer a combined solid phase extraction for trichothecenes, enniatins, beauvericin and zearalenone was firstly developed. The validation of the new method gave satisfying results: intra-day and inter-day precision and recoveries were 1-5%, 2-8% and 72-117%, respectively. In total, 61 different organic and conventional beer samples from Germany and all over the world were analyzed by using the newly developed multi-mycotoxin method. In summary, deoxynivalenol, deoxynivalenol-3-glucoside, 3-acetyldeoxynivaleneol and enniatin B were quantified in rather low contents in the investigated beer samples. None of the other monitored Fusarium toxins like 15-acetyldeoxynivalenol, HT2- and T2-toxin, zearalenone, enniatin B1, A1, A or beauvericin were detectable. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Analytical Method Details (MS): SE2_MS3 [Metabolonote[Archive

    Lifescience Database Archive (English)

    Full Text Available 00.0-1500.0); 2: ITMS + c norm !corona !pi Dep MS/MS Most intense ion from (1)., Rejected mass=284.2000;300.2000;328.2000;344.2000;372.2000;388.2000;416.3000;432.3000;460.0000. ...

  7. Analysis of multiple vitamin D metabolites by ultra-performance supercritical fluid chromatography-tandem mass spectrometry (UPSFC-MS/MS).

    Science.gov (United States)

    Jenkinson, Carl; Taylor, Angela; Storbeck, Karl-Heinz; Hewison, Martin

    2018-06-15

    In recent years, increased interest in the human health benefits of vitamin D has led to demand for improved analysis of patient vitamin D 'status'. Studies to date have focused primarily on a single vitamin D metabolite, 25-hydroxyvitamin D, despite the existence of a broad range of vitamin D metabolites, referred to as the vitamin D metabolome. This study reports on the development of a rapid UPSFC-MS/MS method for the analysis of nine vitamin D metabolites in human serum. Optimum separation was obtained with a Lux-Cellulose chiral column. We observed an orthogonal elution order when compared with ultra-high performance liquid chromatography (UHPLC). The order of elution was reversed based on hydroxyl- group number, however elution order did not differ between isomeric changes in hydroxyl- group position or epimers. Although UPSFC yielded superior resolution and selectivity over previously developed UHPLC-MS/MS methods, improvements in sensitivity could not be achieved owing to the lower injection volume required for UPSFC relative to UHPLC. Method validation was performed on the developed UPSFC-MS/MS method and found to be within acceptable limits. Applying the method to the analysis of human serum samples showed a significant correlation with serum concentrations of metabolites measured by UHPLC-MS/MS (25OHD3 r = 0.997, P=<0.001, and 3-epi-25OHD3 r = 0.996, P ≤0.001). These data indicate that UPSFC provides an efficient analytical platform for rapid analysis of multiple vitamin D metabolites from serum. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  8. Results of a proficiency test for multi-mycotoxin determination in maize by using methods based on LC-MS/(MS)

    NARCIS (Netherlands)

    Solfrizzo, M.; Girolamo, De A.; Lattanzio, V.M.T.; Visconti, A.; Stroka, J.; Alldrick, A.; Egmond, van H.P.

    2013-01-01

    Liquid chromatography coupled with single or tandem mass spectrometry (LC-MS/(MS)) is routinely used for the simultaneous determination of mycotoxins in food and feed although official methods using this technique have not yet been adopted by the European Committee for Standardization and the

  9. Simultaneous determination of metformin and vildagliptin in human plasma by a HILIC-MS/MS method.

    Science.gov (United States)

    Pontarolo, Roberto; Gimenez, Ana Carolina; de Francisco, Thais Martins Guimarães; Ribeiro, Rômulo Pereira; Pontes, Flávia Lada Degaut; Gasparetto, João Cleverson

    2014-08-15

    The objective of this work was to develop and validate a HILIC-MS/MS method for the simultaneous determination of metformin and vildagliptin in human plasma. Chromatographic separation was achieved using an Atlantis HILIC Silica 150-mm × 2.1-mm, 3-μm particle size column maintained at 40°C. The isocratic mobile phase consisted of 20% water and 80% acetonitrile/water solution 95:5 (v/v), containing both 0.1% formic acid and 3mM ammonium formate. The flow rate was maintained at 400 μL min(-1). Data from validation studies demonstrated that the new method is highly selective, sensitive (limits of detection vildagliptin in plasma volunteers who orally received a single dose of metformin (850 mg), vildagliptin (50mg) or drug association (metformin 850 mg+vildagliptin 50mg). The new method can thus also be used as a tool for the clinical monitoring of metformin and vildagliptin. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Targeted LC-MS/MS method for quantification of Plant Lignans and Enterolignans in Biofluids from Humans and Pigs

    DEFF Research Database (Denmark)

    Nørskov, Natalja; Olsen, Anja; Tjønneland, Anne

    2015-01-01

    Lignans have gained nutritional interest due to their promising role in the prevention of lifestyle diseases. However, epidemiological studies are in need of more evidence to link the intake of lignans to this promising role. In this context, it is necessary to study large population groups...... to obtain sufficient statistical power. Therefore, there is a demand for fast, sensitive, and accurate methods for quantitation with high throughput of samples. This paper presents a validated LC-MS/MS method for the quantitation of eight plant lignans (matairesinol, hydroxymatairesinol...

  11. Simple and rapid LC-MS/MS method for the absolute determination of cetuximab in human serum using an immobilized trypsin.

    Science.gov (United States)

    Shibata, Kaito; Naito, Takafumi; Okamura, Jun; Hosokawa, Seiji; Mineta, Hiroyuki; Kawakami, Junichi

    2017-11-30

    Proteomic approaches using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) without an immunopurification technique have not been applied to the determination of serum cetuximab. This study developed a simple and rapid LC-MS/MS method for the absolute determination of cetuximab in human serum and applied it to clinical settings. Surrogate peptides derived from cetuximab digests were selected using a Fourier transform mass spectrometer. Reduced-alkylated serum cetuximab without immunopurification was digested for 20minutes using immobilized trypsin, and the digestion products were purified by solid-phase extraction. The LC-MS/MS was run in positive ion multiple reaction monitoring mode. This method was applied to the determination of serum samples in head and neck cancer patients treated with cetuximab. The chromatographic run time was 10minutes and no peaks interfering with surrogate peptides in serum digestion products were observed. The calibration curve of absolute cetuximab in serum was linear over the concentration range of 4-200μg/mL. The lower limit of quantification of cetuximab in human serum was 4μg/mL. The intra-assay and inter-assay precision and accuracy were less than 13.2% and 88.0-100.7%, respectively. The serum concentration range of cetuximab was 19-140μg/mL in patients. The serum cetuximab concentrations in LC-MS/MS were correlated with those in ELISA (r=0.899, P <0.01) and the mean bias was 1.5% in cancer patients. In conclusion, the present simple and rapid method with acceptable analytical performance can be helpful for evaluating the absolute concentration of serum cetuximab in clinical settings. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. LC-MS/MS method development for quantitative analysis of acetaminophen uptake by the aquatic fungus Mucor hiemalis.

    Science.gov (United States)

    Esterhuizen-Londt, Maranda; Schwartz, Katrin; Balsano, Evelyn; Kühn, Sandra; Pflugmacher, Stephan

    2016-06-01

    Acetaminophen is a pharmaceutical, frequently found in surface water as a contaminant. Bioremediation, in particular, mycoremediation of acetaminophen is a method to remove this compound from waters. Owing to the lack of quantitative analytical method for acetaminophen in aquatic organisms, the present study aimed to develop a method for the determination of acetaminophen using LC-MS/MS in the aquatic fungus Mucor hiemalis. The method was then applied to evaluate the uptake of acetaminophen by M. hiemalis, cultured in pellet morphology. The method was robust, sensitive and reproducible with a lower limit of quantification of 5 pg acetaminophen on column. It was found that M. hiemalis internalize the pharmaceutical, and bioaccumulate it with time. Therefore, M. hiemalis was deemed a suitable candidate for further studies to elucidate its pharmaceutical tolerance and the longevity in mycoremediation applications. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Validated LC-MS/MS Method for the Quantification of Free and Bound Lignans in Cereal-Based Diets and Feces

    DEFF Research Database (Denmark)

    Nørskov, Natalja; Knudsen, Knud Erik Bach

    2016-01-01

    lignans (matairesinol, hydroxymatairesinol, secoisolariciresinol, lariciresinol, isolariciresinol, syringaresinol, medioresinol, and pinoresinol) and two enterolignans (enterodiol and enterolactone) in cereal-based diets/bread and feces. The method consisted of alkaline methanolic extraction combined......Despite the extensive literature describing the biological effects of phenolic compounds from cereals, little is known about their bioaccessibility in the food matrix. This paper describes a validated LC-MS/MS method for the quantification of free and total content (free + bound) of eight plant...

  14. Determination of higenamine in dietary supplements by UHPLC/MS/MS method.

    Science.gov (United States)

    Stajić, A; Anđelković, M; Dikić, N; Rašić, J; Vukašinović-Vesić, M; Ivanović, D; Jančić-Stojanović, B

    2017-11-30

    From 1st January 2017 higenamine was added on the WADA (World Anti-doping Agency) Prohibited list under S3 group beta-2 agonists as at all times banned substance for the athletes. The main origine of higenamine (or norcoclaurine) are different plants including Nandina domestica, Aconitum carmichaelii, Asarum heterotropioides, Galium divaricatum, Annona squamosa, Nelumbo nucifera etc. Higenamine main use is related to weight loss and it could be found (un)labeled in different dietary supplements. The objective of this study was development of sensitive and reliable UHPLC/MS/MS method for determination of higenamine in various dietary supplement samples. In order to obtain high method sensitivity, hydrophilic interaction liquid chromatography (HILIC) mode was applied. Separation was carried out on UHPLC Acquity BEH HILIC analytical column (2.1mm×100mm, 1.7μm particle size). Mobile phase consisted of 0.1% formic acid in water and acetonitrile, respectively, was mixed in ratio of 30:70, v/v. Flow rate was set at 0.2mLmin -1 . Quercetin was used as an internal standard. ESI (+) source ionization mode using multi reaction monitoring (MRM) mode was utilized and three ion transitions of higenamine were followed 272.08→107.01, 272.08→161.07 and 272.08→77.08. Developed method was fully validated and applied for identification and quantification of higenamine in different dietary supplements. According to the results, the most of investigated supplements were free of higenamine, and on the other hand, presence of higenamine was confirmed in some samples while it was not declared on the label. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. A LC-MS-MS method for determination of low doxazosin concentrations in plasma after oral administration to dogs.

    Science.gov (United States)

    Erceg, Marijana; Cindric, Mario; Pozaic Frketic, Lidija; Vertzoni, Maria; Cetina-Cizmek, Biserka; Reppas, Christos

    2010-02-01

    A rapid and sensitive reversed phase liquid chromatography- tandem mass spectrometry (LC-MS-MS) method is developed for the determination of doxazosin in canine plasma. The samples are prepared by precipitation of proteins using a mixture of methanol and acetonitrile, followed by freezing and evaporation of the organic solvent. The remaining dry residue is redissolved in mobile phase and analyzed by LC-MS-MS with positive electrospray ionization using the selected reactions monitoring mode. An XTerra MS C(18) column, a mobile phase composed of acetonitrile and 2mM ammonium acetate with gradient elution, and a flow rate of 400 microL/min are employed. The elution times for prazosin (internal standard) and doxazosin are approximately 8 and 10 min, respectively. Calibration curves are linear in the 1-20 ng/mL concentration range. Limits of detection and quantification are 0.4 ng/mL and 1.2 ng/mL, respectively. Recovery is higher than 94%. Intra- and inter-day relative standard deviations are below 7% and 8%, respectively. The method is applied for the determination of doxazosin plasma levels following a single administration of doxazosin base and doxazosin mesylate tablets (2 mg dose) to dogs in the fed state. The results indicate possible superiority of the mesylate salt on the plasma input rates of doxazosin.

  16. Comparison among four proposed direct blood culture microbial identification methods using MALDI-TOF MS.

    Science.gov (United States)

    Bazzi, Ali M; Rabaan, Ali A; El Edaily, Zeyad; John, Susan; Fawarah, Mahmoud M; Al-Tawfiq, Jaffar A

    Matrix-assisted laser desorption-ionization time-of-flight (MALDI-TOF) mass spectrometry facilitates rapid and accurate identification of pathogens, which is critical for sepsis patients. In this study, we assessed the accuracy in identification of both Gram-negative and Gram-positive bacteria, except for Streptococcus viridans, using four rapid blood culture methods with Vitek MALDI-TOF-MS. We compared our proposed lysis centrifugation followed by washing and 30% acetic acid treatment method (method 2) with two other lysis centrifugation methods (washing and 30% formic acid treatment (method 1); 100% ethanol treatment (method 3)), and picking colonies from 90 to 180min subculture plates (method 4). Methods 1 and 2 identified all organisms down to species level with 100% accuracy, except for Streptococcus viridans, Streptococcus pyogenes, Enterobacter cloacae and Proteus vulgaris. The latter two were identified to genus level with 100% accuracy. Each method exhibited excellent accuracy and precision in terms of identification to genus level with certain limitations. Copyright © 2016 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  17. Evaluation of preparation methods for MS-based analysis of intestinal epithelial cell proteomes

    DEFF Research Database (Denmark)

    Hesselager, Marianne Overgaard; Codrea, Marius Cosmin; Bendixen, Emøke

    2015-01-01

    analyzed by LC and electrospray QTOF-MS. The methods were evaluated according to efficiency, purity, transmembrane protein recovery, as well as for suitability to large-scale preparations. Our data clearly demonstrate that mucosal shaving is by far the best-suited method for in-depth MS analysis in terms...... are low in abundance, and large amounts of sample is needed for their preparation and for undertaking MS-based analysis. The aim of this study was to evaluate three different methods for isolation and preparation of pig intestinal epithelial cells for MS-based analysis of the proteome. Samples were...... of ease and speed of sample preparation, as well as protein recovery. In comparison, more gentle methods where intestinal epithelial cells are harvested by shaking are more time consuming, result in lower protein yield, and are prone to increased technical variation due to multiple steps involved....

  18. Analysis of phytochemical variations in dioecious Tinospora cordifolia stems using HPLC/QTOF MS/MS and UPLC/QqQLIT -MS/MS.

    Science.gov (United States)

    Bajpai, Vikas; Singh, Awantika; Chandra, Preeti; Negi, M P S; Kumar, Nikhil; Kumar, Brijesh

    2016-01-01

    The stem of dioecious Tinospora cordifolia (Menispermaceae) is a commonly used traditional Ayurvedic medicine in India having several therapeutic properties. To develop and validate LC-MS methods for the identification and simultaneous quantitation of various secondary metabolites and to study metabolomic variations in the stem of male and female plants. Ethanolic extract of stems were analysed by HPLC/ESI-QTOF-MS/MS for rapid screening of bioactive phytochemicals. High resolution MS and MS/MS in positive ESI mode were used for structural investigation of secondary metabolites. An UPLC/ESI-QqQ(LIT) -MS/MS method in MRM mode was developed and validated for the simultaneous quantitation of five bioactive alkaloids. Identification and characterisation of 36 metabolites including alkaloids, sesquiterpenes and phytoecdysteroids were performed using LC-MS and MS/MS techniques. The bioactive alkaloids such as jatrorrhizine, magnoflorine, isocorydine, palmatine and tetrahydropalmatine were successfully quantified in male and female plants. The mean abundances of magnoflorine jatrorrhizine, and oblongine were significantly (P Phytochemicals in the stem of male and female Tinospora cordifolia showed significant qualitative and quantitative variations. LC-MS and MS/MS methods can be used to differentiate between male and female plants based on their chemical profiles and quantities of the marker bioactive alkaloids. This chemical composition difference was also evident during vegetative stage when there were no male and female flowers. Copyright © 2015 John Wiley & Sons, Ltd.

  19. Trends in detoxification enzymes and heavy metal accumulation in ground beetles (Coleoptera: Carabidae) inhabiting a gradient of pollution.

    Science.gov (United States)

    Stone, David; Jepson, Paul; Laskowski, Ryszard

    2002-05-01

    Non-specfic carboxylesterase and glutathione S-transferase activity was measured in the ground beetle, Pterosthicus oblongopunctatus (Coleoptera: Carabidae), from five sites along a gradient of heavy metal pollution. A previous study determined that beetles from the two most polluted sites (site codes OLK2 and OLK3) were more susceptible to additional stressors compared with beetles from the reference site (Stone et al., Environ. Pollut. 113, 239-244 2001), suggesting the possibility of physiological impairment. Metal body burdens in ground beetles from five sites along the gradient ranged from 79 to 201 microg/g Zn, 0.174 to 8.66 microg/g Pb and 1.14 to 10.8 microg/g Cd, whereas Cu seemed to be efficiently regulated regardless of metal levels in the soil. Beetle mid- and hindguts were homogenized and the soluble fraction containing glutathione S-transferase (GST) and carboxylesterase (CaE) was assayed using kinetic analyses. Significantly higher levels of GST were found only in female beetles from the most polluted sites (OLK2 and OLK3; P=0.049, Pground beetles in association with metal body burdens.

  20. Validation of an LC-MS/MS method for analysis of anti-diabetic drugs in botanical dietary supplements labeled for blood sugar management.

    Science.gov (United States)

    Ma, Jun; Pawar, Rahul S; Grundel, Erich

    2018-03-01

    We developed and validated a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to detect and quantitate 14 anti-diabetic, 2 anti-obesity, and 3 cholesterol-lowering drugs in botanical dietary supplements marketed for blood sugar management. Many botanical dietary supplements which carry label statements related to blood sugar management are available over the Internet. Potential adulteration of such dietary supplements with anti-diabetic and other prescription drugs, some of which have been removed from the market due to adverse events, is of concern. No significant matrix effects were observed and mean recoveries of all 19 analytes from a single product matrix were 88 to 113% at spiking concentrations from 500 to 2000 μg/g. Mean recoveries of metformin, phenformin, and sibutramine from matrices prepared from multiple product composites ranged from 93 to 115% at a spiking concentration of 100 μg/g. The relative standard deviations (RSD) (%) of intra-day analyses ranged from 0.2 to 13 for all recovery studies. Eighty dietary supplements obtained in the USA and carrying label statements related to blood sugar management were analyzed using this method and none were found to be adulterated with the above 19 drugs. Two products obtained outside of the USA and known to be adulterated were also analyzed by this method and found to contain phenformin, glibenclamide, and sibutramine. This method provided satisfactory selectivity, linearity, accuracy, precision, and sensitivity for rapid determination of 19 drugs and has broad applicability for the analysis of dietary supplements for possible adulteration with these compounds. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

  1. Validation approach for a fast and simple targeted screening method for 75 antibiotics in meat and aquaculture products using LC-MS/MS.

    Science.gov (United States)

    Dubreil, Estelle; Gautier, Sophie; Fourmond, Marie-Pierre; Bessiral, Mélaine; Gaugain, Murielle; Verdon, Eric; Pessel, Dominique

    2017-04-01

    An approach is described to validate a fast and simple targeted screening method for antibiotic analysis in meat and aquaculture products by LC-MS/MS. The strategy of validation was applied for a panel of 75 antibiotics belonging to different families, i.e., penicillins, cephalosporins, sulfonamides, macrolides, quinolones and phenicols. The samples were extracted once with acetonitrile, concentrated by evaporation and injected into the LC-MS/MS system. The approach chosen for the validation was based on the Community Reference Laboratory (CRL) guidelines for the validation of screening qualitative methods. The aim of the validation was to prove sufficient sensitivity of the method to detect all the targeted antibiotics at the level of interest, generally the maximum residue limit (MRL). A robustness study was also performed to test the influence of different factors. The validation showed that the method is valid to detect and identify 73 antibiotics of the 75 antibiotics studied in meat and aquaculture products at the validation levels.

  2. An automated online turboflow cleanup LC/MS/MS method for the determination of 11 plasticizers in beverages and milk.

    Science.gov (United States)

    Ates, Ebru; Mittendorf, Klaus; Senyuva, Hamide

    2013-01-01

    An automated sample preparation technique involving cleanup and analytical separation in a single operation using an online coupled TurboFlow (RP-LC system) is reported. This method eliminates time-consuming sample preparation steps that can be potential sources for cross-contamination in the analysis of plasticizers. Using TurboFlow chromatography, liquid samples were injected directly into the automated system without previous extraction or cleanup. Special cleanup columns enabled specific binding of target compounds; higher MW compounds, i.e., fats and proteins, and other matrix interferences with different chemical properties were removed to waste, prior to LC/MS/MS. Systematic stepwise method development using this new technology in the food safety area is described. Selection of optimum columns and mobile phases for loading onto the cleanup column followed by transfer onto the analytical column and MS detection are critical method parameters. The method was optimized for the assay of 10 phthalates (dimethyl, diethyl, dipropyl, butyl benzyl, diisobutyl, dicyclohexyl, dihexyl, diethylhexyl, diisononyl, and diisododecyl) and one adipate (diethylhexyl) in beverages and milk.

  3. Multiresidue method for pesticide residue analysis in food of animal and plant origin based on GC or LC and MS or MS/MS.

    Science.gov (United States)

    Muñoz, Eva; Muñoz, Gloria; Pineda, Laura; Serrahima, Eulalia; Centrich, Francesc

    2012-01-01

    A multiresidue method based on GC or LC and MS or MS/MS for the determination of 204 pesticides in diverse food matrixes of animal and plant origin is described. The method can include different stages of cleanup according to the chemical characteristics of each sample. Samples were extracted using accelerated solvent extraction. Those with a high fat content or that contained chlorophyll required further purification by gel permeation chromatography and/or SPE (ENVI-Carb). The methodology developed here was fully validated; the LOQs for the 204 pesticides are presented. The LOQ values lie between 0.01 to 0.02 mg/kg. However, in some cases, mainly in baby food, they were as low as 0.003 mg/kg, thereby meeting European Union requirements on maximum residue levels for pesticides, as outlined in European regulation 396/2005 and the Commission Directive 2003/13/EC. The procedure has been accredited for a wide scope of pesticides and matrixes by the Spanish Accreditation Body (ENAC) following ISO/IEC 17025:2005, as outlined in ENAC technical note NT-19.

  4. Validation of a method for the determination of 120 pesticide residues in apples and cucumbers by LC-MS/MS.

    Science.gov (United States)

    Ramadan, Gouda; Al Jabir, Muna; Alabdulmalik, Najat; Mohammed, Ali

    2016-05-01

    Most countries have clearly defined regulations governing the use of pesticides in agricultural activity. The application of pesticides in agriculture usually leads to a residual amount of these pesticides on food products such as fruit and vegetables. The presence of pesticide residues on these foods destined for human consumption may pose food safety risks to consumers. To protect consumers, national authorities have established maximum limits for pesticide residues in foods. These limits can only be enforced if there are methods available to detect and monitor their concentrations in the applicable food products. To support the enforcement of this legislation, we have developed a multi-residue liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the analysis of 120 pesticide residues in apples and cucumbers which has been validated and implemented in the routine monitoring and surveillance programme for these pesticides. In this method, apple and cucumber samples are extracted using the QuEChERS method (quick, easy, cheap, effective, rugged, and safe) and the extracts were analyzed directly by LC-MS/MS. The mean recoveries at three different concentrations of 0.01 µg/g , 0.05 µg/g, and 0.1 µg/g over the analytical range varied between 70 and 120%. The repeatability of the method expressed as %RSD was less than 20%. The limit of detection (LOD) of the method ranged between 0.0014 and 0.0110 µg/g for apples and between 0.0012 and 0.0075 µg/g for cucumbers. The limit of quantification (LOQ) of the method was 0.01 µg/g for apples and cucumbers. The method has been used for the analysis of over 600 apple and 550 cucumber samples over the past two years. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  5. Quantification of methionine and selenomethionine in biological samples using multiple reaction monitoring high performance liquid chromatography tandem mass spectrometry (MRM-HPLC-MS/MS).

    Science.gov (United States)

    Vu, Dai Long; Ranglová, Karolína; Hájek, Jan; Hrouzek, Pavel

    2018-05-01

    Quantification of selenated amino-acids currently relies on methods employing inductively coupled plasma mass spectrometry (ICP-MS). Although very accurate, these methods do not allow the simultaneous determination of standard amino-acids, hampering the comparison of the content of selenated versus non-selenated species such as methionine (Met) and selenomethionine (SeMet). This paper reports two approaches for the simultaneous quantification of Met and SeMet. In the first approach, standard enzymatic hydrolysis employing Protease XIV was applied for the preparation of samples. The second approach utilized methanesulfonic acid (MA) for the hydrolysis of samples, either in a reflux system or in a microwave oven, followed by derivatization with diethyl ethoxymethylenemalonate. The prepared samples were then analyzed by multiple reaction monitoring high performance liquid chromatography tandem mass spectrometry (MRM-HPLC-MS/MS). Both approaches provided platforms for the accurate determination of selenium/sulfur substitution rate in Met. Moreover the second approach also provided accurate simultaneous quantification of Met and SeMet with a low limit of detection, low limit of quantification and wide linearity range, comparable to the commonly used gas chromatography mass spectrometry (GC-MS) method or ICP-MS. The novel method was validated using certified reference material in conjunction with the GC-MS reference method. Copyright © 2018. Published by Elsevier B.V.

  6. Determination of Glyphosate Levels in Breast Milk Samples from Germany by LC-MS/MS and GC-MS/MS

    NARCIS (Netherlands)

    Steinborn, Angelika; Alder, Lutz; Michalski, Britta; Zomer, Paul; Bendig, Paul; Martinez, Sandra Aleson; Mol, Hans G.J.; Class, Thomas J.; Costa Pinheiro, Nathalie

    2016-01-01

    This study describes the validation and application of two independent analytical methods for the determination of glyphosate in breast milk. They are based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-tandem mass spectrometry (GC-MS/MS), respectively. For

  7. Pharmacokinetic studies of bergapten in dog plasma by using a LC-MS/MS method studies.

    Science.gov (United States)

    Gao, Y; Liu, Y Z; Zhang, X-M; Zhou, Y; Zhang, X; Dong, C-Y

    2013-07-01

    A sensitive LC-MS/MS method was developed for the determination of bergapten in dog plasma. The chromatographic separation was carried out on a Hypersil ODS column with a mobile phase consisting of methanol-water. The plasma sample was precipitated with methanol and prepare for injecting onto the LC-MS/MS system. The detection was performed on a triple quadrupole tandem mass spectrometer by MRM via electro spray ionization source. The standard curve for bergapten was linear over the concentration range of 0.5-500 ng/mL with a lower limit of quantification of 0.5 ng/mL. The inter-day and intra-day precision (R.S.D.%) for bergapten varied between 3.4 and 11.5. The corresponding inter-day and intra-day accuracy (Bias%) ranged between -3.8 and 6.9. For the pharmacokinetic analysis of serum, the mean (SD) values obtained for the bergapten were as follows: Cmax, 228.5 (14.3) ng/ml; Tmax, 4.2 (0.4) h; t1/2, 6.9 (2.3) h; AUC0-t h, 2507.2 (168.5) ng · h/mL and AUC0-∞, 3 219.2 (211.4) ng · h/mL, respectively. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Determination of linuron in chamomile by LC-MS/MS using the QuEChERS extraction method

    Directory of Open Access Journals (Sweden)

    Bojana D. Špirović Trifunović

    2015-04-01

    Full Text Available Linuron is a selective herbicide used for the control of broadleaf weeds. Its mode of action is the inhibition of photosynthesis. The QuEChERS method for extraction of linuron residues from chamomile was used. The LC–MS/MS method was used for determination of linuron residues. Its linearity was studied in a range of 0.025-0.50 μg/ml using matrix-matched calibration, and the determination coefficient (R2 was higher than 0.99. Blank chamomile samples were spiked with linuron solution at three concentration levels yielding recoveries of over 90%. The internal standard added in all samples was isoproturon–d6. There were no linuron residues in chamomile flowers, while the residues ranged from 0.010 to 0.040 mg/kg in the flower stalk samples.

  9. A new LC-ESI-MS/MS method to measure long-chain acylcarnitine levels in cultured cells

    International Nuclear Information System (INIS)

    Jauregui, Olga; Sierra, Adriana Y.; Carrasco, Patricia; Gratacos, Esther; Hegardt, Fausto G.; Casals, Nuria

    2007-01-01

    The quantitative evaluation of long-chain acylcarnitines in lipid extracts from cultured cells or tissues is a prerequisite to study carnitine palmitoyltransferase (CPT) activity. There is thus a need for the accurate measurement of the concentration of long-chain acylcarnitines at the lowest concentration present in lipid extracts. Here we report a fast and reliable quantitative method based on the use of weak acid extraction and liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) to quantify acylcarnitines through hydrophilic interaction chromatography. The method was validated using isotopic dilution and the results allow the analysis of a large number of samples at low concentration levels (down to 0.35 nmol L -1 for palmitoylcarnitine) with good inter- and intra-day precision. The method was used for the quantitative study of changes in concentration of palmitoylcarnitine and other acylcarnitines in PC-12 cells over-expressing CPT1a gene. It was also used to measure CPT1 activity in mitochondria isolated from transfected cells, giving similar results to the more common radiometric method, but with higher sensitivity

  10. A new LC-ESI-MS/MS method to measure long-chain acylcarnitine levels in cultured cells

    Energy Technology Data Exchange (ETDEWEB)

    Jauregui, Olga [Scientific and Technical Services, University of Barcelona (Spain); Sierra, Adriana Y.; Carrasco, Patricia; Gratacos, Esther [Molecular and Cellular Unit, School of Health Sciences, International University of Catalonia (Spain); Hegardt, Fausto G. [Department of Biochemistry and Molecular Biology, University of Barcelona, School of Pharmacy (Spain); Casals, Nuria [Molecular and Cellular Unit, School of Health Sciences, International University of Catalonia (Spain)], E-mail: ncasals@csc.uic.es

    2007-09-05

    The quantitative evaluation of long-chain acylcarnitines in lipid extracts from cultured cells or tissues is a prerequisite to study carnitine palmitoyltransferase (CPT) activity. There is thus a need for the accurate measurement of the concentration of long-chain acylcarnitines at the lowest concentration present in lipid extracts. Here we report a fast and reliable quantitative method based on the use of weak acid extraction and liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) to quantify acylcarnitines through hydrophilic interaction chromatography. The method was validated using isotopic dilution and the results allow the analysis of a large number of samples at low concentration levels (down to 0.35 nmol L{sup -1} for palmitoylcarnitine) with good inter- and intra-day precision. The method was used for the quantitative study of changes in concentration of palmitoylcarnitine and other acylcarnitines in PC-12 cells over-expressing CPT1a gene. It was also used to measure CPT1 activity in mitochondria isolated from transfected cells, giving similar results to the more common radiometric method, but with higher sensitivity.

  11. Rapid and reliable QuEChERS-based LC-MS/MS method for determination of acrylamide in potato chips and roasted coffee

    Science.gov (United States)

    Stefanović, S.; Đorđevic, V.; Jelušić, V.

    2017-09-01

    The aim of this paper is to verify the performance characteristics and fitness for purpose of rapid and simple QuEChERS-based LC-MS/MS method for determination of acrylamide in potato chips and coffee. LC-MS/MS is by far the most suitable analytical technique for acrylamide measurements given its inherent sensitivity and selectivity, as well as capability of analyzing underivatized molecule. Acrylamide in roasted coffee and potato chips wasextracted with water:acetonitrile mixture using NaCl and MgSO4. Cleanup was carried out with MgSO4 and PSA. Obtained results were satisfactory. Recoveries were in the range of 85-112%, interlaboratory reproducibility (Cv) was 5.8-7.6% and linearity (R2) was in the range of 0.995-0.999. LoQ was 35 μg kg-1 for coffee and 20 μg kg-1 for potato chips. Performance characteristic of the method are compliant with criteria for analytical methods validation. Presented method for quantitative determination of acrylamide in roasted coffee and potato chips is fit for purposes of self-control in food industry as well as regulatory controls carried out by the governmental agencies.

  12. UPLC-MS/MS based diagnostics for epithelial ovarian cancer using fully sialylated C4-binding protein.

    Science.gov (United States)

    Tanabe, Kazuhiro; Matsuo, Koji; Miyazawa, Masaki; Hayashi, Masaru; Ikeda, Masae; Shida, Masako; Hirasawa, Takeshi; Sho, Ryuichiro; Mikami, Mikio

    2018-05-01

    Serum levels of fully sialylated C4-binding protein (FS-C4BP) are remarkably elevated in patients with epithelial ovarian cancer (EOC) and can be used as a marker to distinguish ovarian clear cell carcinoma from endometrioma. This study aimed to develop a stable, robust and reliable liquid chromatography-hybrid mass spectrometry (UPLC-MS/MS) based diagnostic method that would generalize FS-C4BP as a clinical EOC biomarker. Glycopeptides derived from 20 μL of trypsin-digested serum glycoprotein were analyzed via UPLC equipped with an electrospray ionization time-of-flight mass spectrometer. This UPLC-MS/MS-based diagnostic method was optimized for FS-C4BP and validated using sera from 119 patients with EOC and 127 women without cancer. A1958 (C4BP peptide with two fully sialylated biantennary glycans) was selected as a marker of FS-C4BP because its level in serum was highest among FS-C4BP family members. Preparation and UPLC-MS/MS were optimized for A1958, and performance and robustness were significantly improved relative to our previous method. An area under the curve analysis of the FS-C4BP index receiver operating characteristic curve revealed that the ratio between A1958 and A1813 (C4BP peptide with two partially sialylated biantennary glycans) reached 85%. A combination of the FS-C4BP index and carbohydrate antigen-125 levels further enhanced the sensitivity and specificity. © 2017 The Authors. Biomedical Chromatography published by John Wiley & Sons Ltd.

  13. Ms2lda.org: web-based topic modelling for substructure discovery in mass spectrometry.

    Science.gov (United States)

    Wandy, Joe; Zhu, Yunfeng; van der Hooft, Justin J J; Daly, Rónán; Barrett, Michael P; Rogers, Simon

    2017-09-14

    We recently published MS2LDA, a method for the decomposition of sets of molecular fragment data derived from large metabolomics experiments. To make the method more widely available to the community, here we present ms2lda.org, a web application that allows users to upload their data, run MS2LDA analyses and explore the results through interactive visualisations. Ms2lda.org takes tandem mass spectrometry data in many standard formats and allows the user to infer the sets of fragment and neutral loss features that co-occur together (Mass2Motifs). As an alternative workflow, the user can also decompose a dataset onto predefined Mass2Motifs. This is accomplished through the web interface or programmatically from our web service. The website can be found at http://ms2lda.org , while the source code is available at https://github.com/sdrogers/ms2ldaviz under the MIT license. Supplementary data are available at Bioinformatics online. © The Author(s) 2017. Published by Oxford University Press.

  14. Computer-aided method for identification of major flavone/flavonol glycosides by high-performance liquid chromatography-diode array detection-tandem mass spectrometry (HPLC-DAD-MS/MS).

    Science.gov (United States)

    Wang, Zhengfang; Lin, Longze; Harnly, James M; Harrington, Peter de B; Chen, Pei

    2014-11-01

    A new computational tool is proposed here for tentatively identifying major (UV quantifiable) flavone/flavonol glycoside peaks of high performance liquid chromatogram (HPLC)-diode array detection (DAD)-tandem mass spectrometry (MS/MS) profiles based on a MATLAB-based script implementing an in-house algorithm. The HPLC-DAD-MS/MS profiles of red onion, Chinese lettuce, carrot leaf, and celery seed extracts were analyzed by the proposed computer-aided screening method for identifying possible flavone/flavonol glycoside peaks from the HPLC-UV and MS total ion current (TIC) chromatograms. The number of identified flavone/flavonol glycoside peaks of the HPLC-UV chromatograms is four, four, six, and nine for red onion, Chinese lettuce, carrot leaf, and celery seed, respectively. These results have been validated by human(s) experts. For the batch processing of nine HPLC-DAD-MS/MS profiles of celery seed extract, the entire script execution time was within 15 s while manual calculation of only one HPLC-DAD-MS/MS profile by a flavonoid expert could take hours. Therefore, this MATLAB-based screening method is able to facilitate the HPLC-DAD-MS/MS analysis of flavone/flavonol glycosides in plants to a large extent.

  15. A Collaborative Evaluation of LC-MS/MS Based Methods for BMAA Analysis: Soluble Bound BMAA Found to Be an Important Fraction

    Directory of Open Access Journals (Sweden)

    Elisabeth J. Faassen

    2016-02-01

    Full Text Available Exposure to β-N-methylamino-l-alanine (BMAA might be linked to the incidence of amyotrophic lateral sclerosis, Alzheimer’s disease and Parkinson’s disease. Analytical chemistry plays a crucial role in determining human BMAA exposure and the associated health risk, but the performance of various analytical methods currently employed is rarely compared. A CYANOCOST initiated workshop was organized aimed at training scientists in BMAA analysis, creating mutual understanding and paving the way towards interlaboratory comparison exercises. During this workshop, we tested different methods (extraction followed by derivatization and liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS analysis, or directly followed by LC-MS/MS analysis for trueness and intermediate precision. We adapted three workup methods for the underivatized analysis of animal, brain and cyanobacterial samples. Based on recovery of the internal standard D3BMAA, the underivatized methods were accurate (mean recovery 80% and precise (mean relative standard deviation 10%, except for the cyanobacterium Leptolyngbya. However, total BMAA concentrations in the positive controls (cycad seeds showed higher variation (relative standard deviation 21%–32%, implying that D3BMAA was not a good indicator for the release of BMAA from bound forms. Significant losses occurred during workup for the derivatized method, resulting in low recovery (<10%. Most BMAA was found in a trichloroacetic acid soluble, bound form and we recommend including this fraction during analysis.

  16. Determination of levodopa in human plasma by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS: application to a bioequivalence study

    Directory of Open Access Journals (Sweden)

    Heliana F. Martins

    2013-01-01

    Full Text Available A sensitive, accurate and simple method using HPLC-MS/MS was developed and validated for levodopa quantitation in human plasma. Analysis was achieved on a pursuit® C18 analytical column (5 µm; 150 x 4.6 mm i.d. using a mobile phase (methanol and water , 90:10, v/v containing formic acid 0.5% v/v, after extracting the samples using a simple protein plasma precipitation with perchloric acid. The developed method was validated in accordance with ANVISA guidelines and was successfully applied to a bioequivalence study in 60 healthy volunteers demonstrating the feasibility and reliability of the proposed method.

  17. Quantitative analysis of oxytetracycline and its impurities by LC-MS-MS

    DEFF Research Database (Denmark)

    Lykkeberg, Anne Kruse; Halling-Sørensen, Bent; Cornett, Claus

    2004-01-01

    A liquid chromatographic-tandem mass spectrometric method using an Xterra MS C(18) chromatographic column ( 100 mm x 2.1 mm i.d., 3.5microm) that allows complete separation of oxytetracycline (OTC) and the impurities: 4-epi-oxytetracycline (EOTC), tetracycline (TC), 4-epi-tetracycline (ETC), 2......-acetyl-2-decarboxamido-oxytetracycline (ADOTC), alpha-apo-oxytetracycline (alpha-AOTC) and beta-apo-oxytetracycline (beta-AOTC) was developed. Gradient elution was used and calibration curves were obtained using the scan mode selected reaction monitoring (SRM). Acceptable correlations were obtained...

  18. Development of a LC-MS/MS Method for the Simultaneous Detection of Tricarboxylic Acid Cycle Intermediates in a Range of Biological Matrices

    Directory of Open Access Journals (Sweden)

    Omar Al Kadhi

    2017-01-01

    Full Text Available It is now well-established that perturbations in the tricarboxylic acid (TCA cycle play an important role in the metabolic transformation occurring in cancer including that of the prostate. A method for simultaneous qualitative and quantitative analysis of TCA cycle intermediates in body fluids, tissues, and cultured cell lines of human origin was developed using a common C18 reversed-phase column by LC-MS/MS technique. This LC-MS/MS method for profiling TCA cycle intermediates offers significant advantages including simple and fast preparation of a wide range of human biological samples. The analytical method was validated according to the guideline of the Royal Society of Chemistry Analytical Methods Committee. The limits of detection were below 60 nM for most of the TCA intermediates with the exception of lactic and fumaric acids. The calibration curves of all TCA analytes showed linearity with correlation coefficients r2>0.9998. Recoveries were >95% for all TCA analytes. This method was established taking into consideration problems and limitations of existing techniques. We envisage that its application to different biological matrices will facilitate deeper understanding of the metabolic changes in the TCA cycle from in vitro, ex vivo, and in vivo studies.

  19. Development of an LC/MS/MS method in order to determine arctigenin in rat plasma: its application to a pharmacokinetic study.

    Science.gov (United States)

    Zou, Quanfei; Gu, Yuan; Lu, Rong; Zhang, Tiejun; Zhao, Guang-Rong; Liu, Changxiao; Si, Duanyun

    2013-09-01

    In this study, a simple and sensitive LC/MS/MS method was developed and validated for the determination of arctigenin in rat plasma. The MS detection was performed using multiple reaction monitoring at the transitions of m/z 373.2 → 137.3 for arctigenin and m/z 187.1 → 131.0 for psoralen (internal standard) with a Turbo IonSpray electrospray in positive mode. The calibration curves fitted a good linear relationship over the concentration range of 0.2-500 ng/mL. It was found that arctigenin is not stable enough at both room temperature and -80 °C unless mixed with methanol before storage. The validated LC/MS/MS method was successfully applied for the pharmacokinetic study of arctigenin in rats. After intravenous injection of 0.3 mg/kg arctigenin injection to rats, the maximum concentration, half-life and area under the concentration-time curve were 323 ± 65.2 ng/mL, 0.830 ± 0.166 and 81.0 ± 22.1 h ng/mL, respectively. Copyright © 2013 John Wiley & Sons, Ltd.

  20. Improved methods for urinary atrazine mercapturate analysis-Assessment of an enzyme-linked immunosorbent assay (ELISA) and a novel liquid chromatography-mass spectrometry (LC-MS) method utilizing online solid phase extraction (SPE)

    International Nuclear Information System (INIS)

    Koivunen, Marja E.; Dettmer, Katja; Vermeulen, Roel; Bakke, Berit; Gee, Shirley J.; Hammock, Bruce D.

    2006-01-01

    Elimination of interfering substances in urine by solid phase extraction (SPE) prior to analysis resulted in 10-fold improvement in the sensitivity of atrazine mercapturate (AM) enzyme-linked immunosorbent assay (ELISA) compared to previous reports. Of the two tested SPE systems, Oasis[reg] HLB and MCX, the mixed-mode MCX gave good recoveries (82%) of AM in spiked samples measured by ELISA, whereas the reverse-phase HLB phase was not compatible with the immunochemical method. At relatively high concentrations of urinary AM (>20 ng mL -1 ), sample dilution was effective enough for the elimination of interfering substances. The new liquid chromatography-mass spectrometry (LC-MS) method developed for AM utilizes online-SPE with Oasis[reg] HLB, column switching and a stable-isotope internal standard. The limit of quantification (0.05 ng mL -1 ) indicates improved sensitivity compared with most previously published LC-MS methods for AM. Validation of all three methods, LC-MS, ELISA + SPE and ELISA + dilution with spiked urine samples showed good correlation between the known and measured concentrations with R 2 values of 0.996, 0.957 and 0.961, respectively. When a set (n = 70 plus 12 blind duplicates) of urine samples from farmers exposed to atrazine was analyzed, there was a good agreement (R 2 = 0.917) between the log normalized data obtained by ELISA + SPE and LC-MS. High correlation among the data obtained by the two tested methods and the LC-MS method by the Center of Disease Control and Prevention (CDC), together with low variability among the blind duplicates, suggests that both methods reported here would be suitable for the analysis of urinary AM as a biomarker for human exposure of atrazine

  1. Simultaneous analysis of multiple classes of antimicrobials in environmental water samples using SPE coupled with UHPLC-ESI-MS/MS and isotope dilution.

    Science.gov (United States)

    Tran, Ngoc Han; Chen, Hongjie; Do, Thanh Van; Reinhard, Martin; Ngo, Huu Hao; He, Yiliang; Gin, Karina Yew-Hoong

    2016-10-01

    A robust and sensitive analytical method was developed for the simultaneous analysis of 21 target antimicrobials in different environmental water samples. Both single SPE and tandem SPE cartridge systems were investigated to simultaneously extract multiple classes of antimicrobials. Experimental results showed that good extraction efficiencies (84.5-105.6%) were observed for the vast majority of the target analytes when extraction was performed using the tandem SPE cartridge (SB+HR-X) system under an extraction pH of 3.0. HPLC-MS/MS parameters were optimized for simultaneous analysis of all the target analytes in a single injection. Quantification of target antimicrobials in water samples was accomplished using 15 isotopically labeled internal standards (ILISs), which allowed the efficient compensation of the losses of target analytes during sample preparation and correction of matrix effects during UHPLC-MS/MS as well as instrument fluctuations in MS/MS signal intensity. Method quantification limit (MQL) for most target analytes based on SPE was below 5ng/L for surface waters, 10ng/L for treated wastewater effluents, and 15ng/L for raw wastewater. The method was successfully applied to detect and quantify the occurrence of the target analytes in raw influent, treated effluent and surface water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Determination of Urinary PAH Metabolites Using DLLME Hyphenated to Injector Port Silylation and GC-MS-MS.

    Science.gov (United States)

    Gupta, Manoj Kumar; Jain, Rajeev; Singh, Pratibha; Ch, Ratnasekhar; Mudiam, Mohana Krishna Reddy

    2015-06-01

    Polycyclic aromatic hydrocarbons (PAHs) are ubiquitous environmental pollutants and well-known carcinogens. Hydroxy derivatives of PAH are considered as biomarkers of PAH exposure, and there is a need to measure these metabolites at low concentrations. So, a precise and eco-friendly analytical method has been developed for rapid determination of PAH metabolites. For the first time, a new analytical method based on coupling of dispersive liquid-liquid microextraction (DLLME) with auto-injector port silylation (auto-IPS) followed by gas chromatography-tandem mass spectrometry (GC-MS-MS) analysis is reported for the analysis of seven urinary PAH metabolites. Factors affecting DLLME and IPS, such as type and volume of extraction and disperser solvent, pH, ionic strength, injector port temperature, volume of N,O-bis(trimethylsilyl)trifluoroacetamide and type of solvent were investigated. Under optimized conditions, the limit of detection and limit of quantification were found to be in the range of 1-9 and 3-29 ng/mL, respectively. Satisfactory recoveries of metabolites in urine samples in the range of 87-95% were found. The developed method has been successfully applied for the determination of PAH metabolites in urine samples of exposed workers. DLLME-auto-IPS-GC-MS-MS method is time, labor, solvent and reagent saving, which can be routinely used for the analysis of urinary PAH metabolites. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. HPLC and LC-MS/MS methods for determination of sodium benzoate and potassium sorbate in food and beverages: performances of local accredited laboratories via proficiency tests in Turkey.

    Science.gov (United States)

    Gören, Ahmet C; Bilsel, Gökhan; Şimşek, Adnan; Bilsel, Mine; Akçadağ, Fatma; Topal, Kevser; Ozgen, Hasan

    2015-05-15

    High Performance Liquid Chromatography LC-UV and LC-MS/MS methods were developed and validated for quantitative analyses of sodium benzoate and potassium sorbate in foods and beverages. HPLC-UV and LC-MS/MS methods were compared for quantitative analyses of sodium benzoate and potassium sorbate in a representative ketchup sample. Optimisation of the methods enabled the chromatographic separation of the analytes in less than 4 min. A correlation coefficient of 0.999 was achieved over the measured calibration range for both compounds and methods (HPLC and LC-MS/MS). The uncertainty values of sodium benzoate and potassium sorbate were found as 0.199 and 0.150 mg/L by HPLC and 0.072 and 0.044 mg/L by LC-MS/MS, respectively. Proficiency testing performance of Turkish accredited laboratories between the years 2005 and 2013 was evaluated and reported herein. The aim of the proficiency testing scheme was to evaluate the performance of the laboratories, analysing benzoate and sorbate in tomato ketchup. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. RAId_aPS: MS/MS analysis with multiple scoring functions and spectrum-specific statistics.

    Science.gov (United States)

    Alves, Gelio; Ogurtsov, Aleksey Y; Yu, Yi-Kuo

    2010-11-16

    Statistically meaningful comparison/combination of peptide identification results from various search methods is impeded by the lack of a universal statistical standard. Providing an E-value calibration protocol, we demonstrated earlier the feasibility of translating either the score or heuristic E-value reported by any method into the textbook-defined E-value, which may serve as the universal statistical standard. This protocol, although robust, may lose spectrum-specific statistics and might require a new calibration when changes in experimental setup occur. To mitigate these issues, we developed a new MS/MS search tool, RAId_aPS, that is able to provide spectrum-specific-values for additive scoring functions. Given a selection of scoring functions out of RAId score, K-score, Hyperscore and XCorr, RAId_aPS generates the corresponding score histograms of all possible peptides using dynamic programming. Using these score histograms to assign E-values enables a calibration-free protocol for accurate significance assignment for each scoring function. RAId_aPS features four different modes: (i) compute the total number of possible peptides for a given molecular mass range, (ii) generate the score histogram given a MS/MS spectrum and a scoring function, (iii) reassign E-values for a list of candidate peptides given a MS/MS spectrum and the scoring functions chosen, and (iv) perform database searches using selected scoring functions. In modes (iii) and (iv), RAId_aPS is also capable of combining results from different scoring functions using spectrum-specific statistics. The web link is http://www.ncbi.nlm.nih.gov/CBBresearch/Yu/raid_aps/index.html. Relevant binaries for Linux, Windows, and Mac OS X are available from the same page.

  5. Orthogonal analytical methods for botanical standardization: determination of green tea catechins by qNMR and LC-MS/MS.

    Science.gov (United States)

    Napolitano, José G; Gödecke, Tanja; Lankin, David C; Jaki, Birgit U; McAlpine, James B; Chen, Shao-Nong; Pauli, Guido F

    2014-05-01

    The development of analytical methods for parallel characterization of multiple phytoconstituents is essential to advance the quality control of herbal products. While chemical standardization is commonly carried out by targeted analysis using gas or liquid chromatography-based methods, more universal approaches based on quantitative (1)H NMR (qHNMR) measurements are being used increasingly in the multi-targeted assessment of these complex mixtures. The present study describes the development of a 1D qHNMR-based method for simultaneous identification and quantification of green tea constituents. This approach utilizes computer-assisted (1)H iterative Full Spin Analysis (HiFSA) and enables rapid profiling of seven catechins in commercial green tea extracts. The qHNMR results were cross-validated against quantitative profiles obtained with an orthogonal LC-MS/MS method. The relative strengths and weaknesses of both approaches are discussed, with special emphasis on the role of identical reference standards in qualitative and quantitative analyses. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Eco-friendly LC-MS/MS method for analysis of multi-class micropollutants in tap, fountain, and well water from northern Portugal.

    Science.gov (United States)

    Barbosa, Marta O; Ribeiro, Ana R; Pereira, Manuel F R; Silva, Adrián M T

    2016-11-01

    Organic micropollutants present in drinking water (DW) may cause adverse effects for public health, and so reliable analytical methods are required to detect these pollutants at trace levels in DW. This work describes the first green analytical methodology for multi-class determination of 21 pollutants in DW: seven pesticides, an industrial compound, 12 pharmaceuticals, and a metabolite (some included in Directive 2013/39/EU or Decision 2015/495/EU). A solid-phase extraction procedure followed by ultra-high-performance liquid chromatography coupled to tandem mass spectrometry (offline SPE-UHPLC-MS/MS) method was optimized using eco-friendly solvents, achieving detection limits below 0.20 ng L -1 . The validated analytical method was successfully applied to DW samples from different sources (tap, fountain, and well waters) from different locations in the north of Portugal, as well as before and after bench-scale UV and ozonation experiments in spiked tap water samples. Thirteen compounds were detected, many of them not regulated yet, in the following order of frequency: diclofenac > norfluoxetine > atrazine > simazine > warfarin > metoprolol > alachlor > chlorfenvinphos > trimethoprim > clarithromycin ≈ carbamazepine ≈ PFOS > citalopram. Hazard quotients were also estimated for the quantified substances and suggested no adverse effects to humans. Graphical Abstract Occurrence and removal of multi-class micropollutants in drinking water, analyzed by an eco-friendly LC-MS/MS method.

  7. Quantification of amlodipine and atorvastatin in human plasma by UPLC-MS/MS method and its application to a bioequivalence study.

    Science.gov (United States)

    Rezk, Mamdouh R; Badr, Kamal A

    2018-07-01

    A robust, rapid and sensitive UPLC-MS/MS method has been developed, optimized and validated for the determination of amlodipine (AML) and atorvastatin (ATO) in human plasma using eplerenone as an internal standard (IS). Multiple-reaction monitoring in positive electrospray ionization mode was utilized in Xevo TQD LC-MS/MS. Double extraction was used in sample preparation using diethyl ether and ethyl acetate. The prepared samples were analyzed using an Acquity UPLC BEH C 18 (50 × 2.1 mm, 1.7 μm) column. Ammonium formate and acetonitrile, pumped isocraticaly at a flow rate of 0.25 mL/min, were used as a mobile phase. Method validation was done as per the US Food and Drug Administration guidelines. Linearity was achieved in the range of 0.1-10 ng/mL for AML and 0.05-50 ng/mL for ATO. Intra-day and inter-day accuracy and precision were calculated and found to be within the acceptable range. A short run time, of <1.5 min, permits analysis of a large number of plasma samples per batch. The developed and validated method was applied to estimate AML and ATO in a bioequivalence study in healthy human volunteers. Copyright © 2018 John Wiley & Sons, Ltd.

  8. Development and validation of an LC-MS/MS method for the determination of adapalene in pharmaceutical forms for skin application

    Directory of Open Access Journals (Sweden)

    Dobričić Vladimir

    2016-01-01

    Full Text Available Development and validation of a liquid chromatography - tandem mass spectrometry (LC-MS/MS method for the determination of adapalene in pharmaceutical forms for skin application were presented. The MS/MS analysis of adapalene was performed by use of three mobile phases, consisted of acetonitrile and (a 0.1 % formic acid, (b 0.1 % trifluoroacetic acid and (c 20 mM ammonium acetate. The strongest signals of parent ion and dominant product ion were obtained in negative mode by use of the mobile phase (c. Validation of this method was performed according to the ICH guidelines. Small variations of selected chromatographic parameters (concentration of ammonium acetate, mobile phase composition, column temperature and flow rate did not affect qualitative and quantitative system responses significantly, which proved method’s robustness. The method is specific for the determination of adapalene. Linearity was proved in the concentration range 6.7 - 700.0 ng mL-1 (r = 0.9990, with limits of detection and quantification 2.0 ng mL-1 and 6.7 ng mL-1, respectively. Accuracy was confirmed by calculated recoveries (98.4 % - 101.5 %. Precision was tested at three levels: injection repeatability, analysis repeatability and intermediate precision. Calculated relative standard deviations were less than 1, 2 and 3 %, respectively. [Projekat Ministartsva nauke Republike Srbije, br. OI172041 i br. TR34031

  9. Development of a SIDA-LC-MS/MS Method for the Determination of Phomopsin A in Legumes.

    Science.gov (United States)

    Schloß, Svenja; Koch, Matthias; Rohn, Sascha; Maul, Ronald

    2015-12-09

    A novel method for the determination of phomopsin A (1) in lupin flour, pea flour, and bean flour as well as whole lupin plants was established based on stable isotope dilution assay (SIDA) LC-MS/MS using (15)N6-1 as an isotopically labeled internal standard. Artificially infected samples were used to develop an optimized extraction procedure and sample pretreatment. The limits of detection were 0.5-1 μg/kg for all matrices. The limits of quantitation were 2-4 μg/kg. The method was used to analyze flour samples generated from selected legume seeds and lupin plant samples that had been inoculated with Diaporthe toxica and two further fungal strains. Finally, growing lupin plants infected with D. toxica were investigated to simulate a naturally in-field mycotoxicosis. Toxin levels of up to 10.1 μg/kg of 1 were found in the pods and 7.2 μg/kg in the stems and leaves.

  10. Matrix Effect Evaluation and Method Validation of Azoxystrobin and Difenoconazole Residues in Red Flesh Dragon Fruit (Hylocereus polyrhizus) Matrices Using QuEChERS Sample Preparation Methods Followed by LC-MS/MS Determination.

    Science.gov (United States)

    Noegrohati, Sri; Hernadi, Elan; Asviastuti, Syanti

    2018-03-30

    Production of red flesh dragon fruit (Hylocereus polyrhizus) was hampered by Colletotrichum sp. Pre-harvest application of azoxystrobin and difenoconazole mixture is recommended, therefore, a selective and sensitive multi residues analytical method is required in monitoring and evaluating the commodity's safety. LC-MS/MS is a well-established analytical technique for qualitative and quantitative determination in complex matrices. However, this method is hurdled by co-eluted coextractives interferences. This work evaluated the pH effect of acetate buffered and citrate buffered QuEChERS sample preparation in their effectiveness of matrix effect reduction. Citrate buffered QuEChERS proved to produce clean final extract with relative matrix effect 0.4%-0.7%. Method validation of the selected sample preparation followed by LC-MS/MS for whole dragon fruit, flesh and peel matrices fortified at 0.005, 0.01, 0.1 and 1 g/g showed recoveries 75%-119%, intermediate repeatability 2%-14%. The expanded uncertainties were 7%-48%. Based on the international acceptance criteria, this method is valid.

  11. Establish an automated flow injection ESI-MS method for the screening of fragment based libraries: Application to Hsp90.

    Science.gov (United States)

    Riccardi Sirtori, Federico; Caronni, Dannica; Colombo, Maristella; Dalvit, Claudio; Paolucci, Mauro; Regazzoni, Luca; Visco, Carlo; Fogliatto, Gianpaolo

    2015-08-30

    ESI-MS is a well established technique for the study of biopolymers (nucleic acids, proteins) and their non covalent adducts, due to its capacity to detect ligand-target complexes in the gas phase and allows inference of ligand-target binding in solution. In this article we used this approach to investigate the interaction of ligands to the Heat Shock Protein 90 (Hsp90). This enzyme is a molecular chaperone involved in the folding and maturation of several proteins which has been subjected in the last years to intensive drug discovery efforts due to its key role in cancer. In particular, reference compounds, with a broad range of dissociation constants from 40pM to 100μM, were tested to assess the reliability of ESI-MS for the study of protein-ligand complexes. A good agreement was found between the values measured with a fluorescence polarization displacement assay and those determined by mass spectrometry. After this validation step we describe the setup of a medium throughput screening method, based on ESI-MS, suitable to explore interactions of therapeutic relevance biopolymers with chemical libraries. Our approach is based on an automated flow injection ESI-MS method (AFI-MS) and has been applied to screen the Nerviano Medical Sciences proprietary fragment library of about 2000 fragments against Hsp90. In order to discard false positive hits and to discriminate those of them interacting with the N-terminal ATP binding site, competition experiments were performed using a reference inhibitor. Gratifyingly, this group of hits matches with the ligands previously identified by NMR FAXS techniques and confirmed by X-ray co-crystallization experiments. These results support the use of AFI-MS for the screening of medium size libraries, including libraries of small molecules with low affinity typically used in fragment based drug discovery. AFI-MS is a valid alternative to other techniques with the additional opportunities to identify compounds interacting with

  12. An Effective Grouping Method for Privacy-Preserving Bike Sharing Data Publishing

    Directory of Open Access Journals (Sweden)

    A S M Touhidul Hasan

    2017-10-01

    Full Text Available Bike sharing programs are eco-friendly transportation systems that are widespread in smart city environments. In this paper, we study the problem of privacy-preserving bike sharing microdata publishing. Bike sharing systems collect visiting information along with user identity and make it public by removing the user identity. Even after excluding user identification, the published bike sharing dataset will not be protected against privacy disclosure risks. An adversary may arrange published datasets based on bike’s visiting information to breach a user’s privacy. In this paper, we propose a grouping based anonymization method to protect published bike sharing dataset from linking attacks. The proposed Grouping method ensures that the published bike sharing microdata will be protected from disclosure risks. Experimental results show that our approach can protect user privacy in the released datasets from disclosure risks and can keep more data utility compared with existing methods.

  13. Determination of Ten Corticosteroids in Illegal Cosmetic Products by a Simple, Rapid, and High-Performance LC-MS/MS Method

    Directory of Open Access Journals (Sweden)

    Vita Giaccone

    2017-01-01

    Full Text Available The aim of our present work was the development of a rapid high-performance liquid chromatography method with electrospray ionization and tandem mass spectrometry detection (LC-ESI-MS/MS for the determination of several corticosteroids in cosmetic products. Corticosteroids are suspected to be illegally added in cosmetic preparations in order to enhance the curative effect against some skin diseases. Sample preparation step consists in a single extraction with acetonitrile followed by centrifugation and filtration. The compounds were separated by reversed-phase chromatography with water and acetonitrile (both with 0.1% formic acid gradient elution and detected by ESI-MS positive and negative ionization mode. The method was validated at the validation level of 0.1 mg kg−1. Linearity was studied in the 5–250 μg L−1 range and linear coefficients (r2 were all over 0.99. The accuracy and precision of the method were satisfactory. The LOD ranged from 0.085 to 0.109 mg kg−1 and the LOQ from 0.102 to 0.121 mg kg−1. Mean recoveries for all the analytes were within the range 91.9–99.2%. The developed method is sensitive and useful for detection, quantification, and confirmation of these corticosteroids in cosmetic preparations and can be applied in the analysis of the suspected samples under investigation.

  14. MALDI-TOF MS/MS measurements of PMMA

    NARCIS (Netherlands)

    Becer, C.R.; Baumgaertel, A.; Gottschaldt, M.; Schubert, U.S.

    2008-01-01

    The polymer poly(Me methacrylate) (PMMA) was analyzed using the matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) technique. The MALDI-TOF MS app. was coupled with a collision-induced dissocn. (CID) unit. The performance of the MALDI-TOF/TOF MS method in

  15. Development of a chromatographic separation method hyphenated to electro-spray ionization mass spectrometry (ESI-MS) and inductively coupled plasma mass spectrometry (ICP-MS): application to the lanthanides speciation analysis

    International Nuclear Information System (INIS)

    Beuvier, Ludovic

    2015-01-01

    This work focuses on the development of a chromatographic separation method coupled to both ESI-MS and ICP-MS in order to achieve the comprehensive speciation analysis of lanthanides in aqueous phase representative of back-extraction phases of advanced spent nuclear fuel treatment processes. This analytical method allowed the separation, the characterization and the quantitation of lanthanides complexes holding poly-aminocarboxylic ligands, such as DTPA and EDTA, used as complexing agents in these processes. A HILIC separation method of lanthanides complexes has been developed with an amide bonded stationary phase. A screening of a wide range of mobile phase compositions demonstrated that the adsorption mechanism was predominant. This screening allowed also obtaining optimized separation conditions. Faster analysis conditions with shorter amide column packed with sub 2 μm particles reduced analysis time by 2.5 and 25% solvent consumption. Isotopic and structural characterization by HILIC ESI-MS was performed as well as the development of external calibration quantitation method. Analytical performances of quantitation method were determined. Finally, the development of the HILIC coupling to ESI-MS and ICP-MS was achieved. A simultaneous quantitation method by ESI-MS and ICP-MS was performed to determine the species quantitative distribution in solution. Analytical performances of quantitation method were also determined. (author) [fr

  16. Bioavailability of wilforlide A in mice and its concentration determination using an HPLC-APCI-MS/MS method.

    Science.gov (United States)

    Wang, Zhijun; Yeung, Steven; Chen, Shang; Moatazedi, Yasmin; Chow, Moses S S

    2018-07-15

    Wilforlide A (WA), an active compound in Tripterygium wilfordii Hook F (TW) which is a traditional Chinese medicine for treatment of autoimmune diseases, is a quality control marker for TW product. At present, the bioavailability/pharmacokinetics of WA is not known. Such information is not only essential to evaluate the relevance of WA as a quality control maker, but also important for future clinical efficacy studies. Therefore, a high-performance liquid chromatography-atmospheric pressure chemical ionization tandem mass spectrometric method (HPLC-APCI-MS/MS) was developed and applied to a bioavailability/pharmacokinetic study of WA. WA and celastrol (the internal standard, IS) were extracted by a liquid-liquid extraction method using methyl tert-butyl ether. Multiple reaction monitoring (MRM) scanning in positive ionization mode was used to monitor the transition of m/z 455.1 to 191.3 for WA and 451.3 to 201.2 for IS. This method was validated and applied to a pharmacokinetic study of WA in mice following intravenous administration (IV, 1.2 mg/kg), intraperitoneal injection (IP, 6 mg/kg) and oral administration (PO, 30 mg/kg). The lower limit of quantification (LLOQ) for WA was 10 ng/ml. The intra- and inter-day precision was found to be within 15.4% while the accuracy within 94.1-115.7% for all the quality control and LLOQ samples. The samples were stable under all the usual storage and experimental conditions. The terminal elimination half-lives were 14.7, 9.1 and 22.7 min following IV, IP and PO dosing, while the absolute bioavailability for IP and PO WA were 9.39% and 0.58% respectively. These results indicated that the HPLC-APCI-MS/MS assay was suitable for the pharmacokinetic study of WA. WA was found poorly absorbed when given orally and therefore it may not be a relevant marker for the oral TW products in the market. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. A proteomics method using immunoaffinity fluorogenic derivatization-liquid chromatography/tandem mass spectrometry (FD-LC-MS/MS) to identify a set of interacting proteins.

    Science.gov (United States)

    Nakata, Katsunori; Saitoh, Ryoichi; Ishigai, Masaki; Imai, Kazuhiro

    2018-02-01

    Biological functions in organisms are usually controlled by a set of interacting proteins, and identifying the proteins that interact is useful for understanding the mechanism of the functions. Immunoprecipitation is a method that utilizes the affinity of an antibody to isolate and identify the proteins that have interacted in a biological sample. In this study, the FD-LC-MS/MS method, which involves fluorogenic derivatization followed by separation and quantification by HPLC and finally identification of proteins by HPLC-tandem mass spectrometry, was used to identify proteins in immunoprecipitated samples, using heat shock protein 90 (HSP90) as a model of an interacting protein in HepaRG cells. As a result, HSC70 protein, which was known to form a complex with HSP90, was isolated, together with three different types of HSP90-beta. The results demonstrated that the proposed immunoaffinity-FD-LC-MS/MS method could be useful for simultaneously detecting and identifying the proteins that interact with a certain protein. Copyright © 2017 John Wiley & Sons, Ltd.

  18. Urinary amino acid analysis: a comparison of iTRAQ-LC-MS/MS, GC-MS, and amino acid analyzer.

    Science.gov (United States)

    Kaspar, Hannelore; Dettmer, Katja; Chan, Queenie; Daniels, Scott; Nimkar, Subodh; Daviglus, Martha L; Stamler, Jeremiah; Elliott, Paul; Oefner, Peter J

    2009-07-01

    Urinary amino acid analysis is typically done by cation-exchange chromatography followed by post-column derivatization with ninhydrin and UV detection. This method lacks throughput and specificity. Two recently introduced stable isotope ratio mass spectrometric methods promise to overcome those shortcomings. Using two blinded sets of urine replicates and a certified amino acid standard, we compared the precision and accuracy of gas chromatography/mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) of propyl chloroformate and iTRAQ derivatized amino acids, respectively, to conventional amino acid analysis. The GC-MS method builds on the direct derivatization of amino acids in diluted urine with propyl chloroformate, GC separation and mass spectrometric quantification of derivatives using stable isotope labeled standards. The LC-MS/MS method requires prior urinary protein precipitation followed by labeling of urinary and standard amino acids with iTRAQ tags containing different cleavable reporter ions distinguishable by MS/MS fragmentation. Means and standard deviations of percent technical error (%TE) computed for 20 amino acids determined by amino acid analyzer, GC-MS, and iTRAQ-LC-MS/MS analyses of 33 duplicate and triplicate urine specimens were 7.27+/-5.22, 21.18+/-10.94, and 18.34+/-14.67, respectively. Corresponding values for 13 amino acids determined in a second batch of 144 urine specimens measured in duplicate or triplicate were 8.39+/-5.35, 6.23+/-3.84, and 35.37+/-29.42. Both GC-MS and iTRAQ-LC-MS/MS are suited for high-throughput amino acid analysis, with the former offering at present higher reproducibility and completely automated sample pretreatment, while the latter covers more amino acids and related amines.

  19. High-throughput method for macrolides and lincosamides antibiotics residues analysis in milk and muscle using a simple liquid-liquid extraction technique and liquid chromatography-electrospray-tandem mass spectrometry analysis (LC-MS/MS).

    Science.gov (United States)

    Jank, Louise; Martins, Magda Targa; Arsand, Juliana Bazzan; Campos Motta, Tanara Magalhães; Hoff, Rodrigo Barcellos; Barreto, Fabiano; Pizzolato, Tânia Mara

    2015-11-01

    A fast and simple method for residue analysis of the antibiotics classes of macrolides (erythromycin, azithromycin, tylosin, tilmicosin and spiramycin) and lincosamides (lincomycin and clindamycin) was developed and validated for cattle, swine and chicken muscle and for bovine milk. Sample preparation consists in a liquid-liquid extraction (LLE) with acetonitrile, followed by liquid chromatography-electrospray-tandem mass spectrometry analysis (LC-ESI-MS/MS), without the need of any additional clean-up steps. Chromatographic separation was achieved using a C18 column and a mobile phase composed by acidified acetonitrile and water. The method was fully validated according the criteria of the Commission Decision 2002/657/EC. Validation parameters such as limit of detection, limit of quantification, linearity, accuracy, repeatability, specificity, reproducibility, decision limit (CCα) and detection capability (CCβ) were evaluated. All calculated values met the established criteria. Reproducibility values, expressed as coefficient of variation, were all lower than 19.1%. Recoveries range from 60% to 107%. Limits of detection were from 5 to 25 µg kg(-1).The present method is able to be applied in routine analysis, with adequate time of analysis, low cost and a simple sample preparation protocol. Copyright © 2015. Published by Elsevier B.V.

  20. Contribution to the development of new analytical methods by the coupling between capillary electrophoresis and mass spectrometry (ICP-MS and ESI-MS): applications to the nuclear and biological fields; Contribution au developpement de nouvelles methodes analytiques par le couplage entre l'electrophorese capillaire et la spectrometrie de masse (ICP-MS et ESI-MS): applications dans les domaines nucleaires et biologiques

    Energy Technology Data Exchange (ETDEWEB)

    Pitois, A

    2006-04-15

    The coupling between chromatographic and electrophoretic separation techniques and mass spectrometry is used to combine the efficiency of the separation technique to the selectivity and sensitivity of the detectors. In this work, the number of applications of the CE-MS couplings has been increased. New analytical methods have been set up in the nuclear and biological fields. New analytical methods for the determination of fission products (cesium and lanthanides) have been developed by CE-ICP-MS. They enable to determine both concentration and isotopic composition of the fission products for very low detection limits (ng/mL by CE-Q-ICPMS, pg/mL by CE-HR-ICP-MS), since all the isobaric interferences are resolved. Moreover, only some nano-liters of sample are necessary to perform the analysis. These method have been applied with success to a simulated sample of spent fuel, to a nuclear sample from PUREX process and to a leaching of MOX fuel. Then, lanthanides have been analysed by CE-ESI-MS and the capability of ESI-MS to provide structural information has been studied. Elementary information has been obtained for strong potentials. Structural information has been obtained for low potentials. Finally, a new analytical method by CE-ESI-MS for the determination of 10B-boronophenylalanine (10B-BPA) has been developed for Boron Neutron Capture Therapy (BNCT). It has been applied to the cellular lines F98 and HUVEC. This CE-ESI-MS method has been validated by HR-ICP-MS. It enables a direct quantification of the chemical form 10B-BPA in samples of limited size (some nano-liters) and for low concentrations (ng/mL). As a consequence, this CE-ESI-MS method has enabled the study of the kinetics of 10B-BPA release and uptake for the F98 cells. (author)

  1. Development of a fast isocratic LC-MS/MS method for the high-throughput analysis of pyrrolizidine alkaloids in Australian honey.

    Science.gov (United States)

    Griffin, Caroline T; Mitrovic, Simon M; Danaher, Martin; Furey, Ambrose

    2015-01-01

    Honey samples originating from Australia were purchased and analysed for targeted pyrrolizidine alkaloids (PAs) using a new and rapid isocratic LC-MS/MS method. This isocratic method was developed from, and is comparable with, a gradient elution method and resulted in no loss of sensitivity or reduction in chromatographic peak shape. Isocratic elution allows for significantly shorter run times (6 min), eliminates the requirement for column equilibration periods and, thus, has the advantage of facilitating a high-throughput analysis which is particularly important for regulatory testing laboratories. In excess of two hundred injections are possible, with this new isocratic methodology, within a 24-h period which is more than 50% improvement on all previously published methodologies. Good linear calibrations were obtained for all 10 PAs and four PA N-oxides (PANOs) in spiked honey samples (3.57-357.14 µg l(-1); R(2) ≥ 0.9987). Acceptable inter-day repeatability was achieved for the target analytes in honey with % RSD values (n = 4) less than 7.4%. Limits of detection (LOD) and limits of quantitation (LOQ) were achieved with spiked PAs and PANOs samples; giving an average LOD of 1.6 µg kg(-1) and LOQ of 5.4 µg kg(-1). This method was successfully applied to Australian and New Zealand honey samples sourced from supermarkets in Australia. Analysis showed that 41 of the 59 honey samples were contaminated by PAs with the mean total sum of PAs being 153 µg kg(-1). Echimidine and lycopsamine were predominant and found in 76% and 88%, respectively, of the positive samples. The average daily exposure, based on the results presented in this study, were 0.051 µg kg(-1) bw day(-1) for adults and 0.204 µg kg(-1) bw day(-1) for children. These results are a cause for concern when compared with the proposed European Food Safety Authority (EFSA), Committee on Toxicity (COT) and Bundesinstitut für Risikobewertung (BfR - Federal Institute of Risk Assessment Germany) maximum

  2. Single Laboratory Validated Method for Determination of Cylindrospermopsin and Anatoxin-a in Ambient Water by Liquid Chromatography/ Tandem Mass Spectrometry (LC/MS/MS)

    Science.gov (United States)

    This product is an LC/MS/MS single laboratory validated method for the determination of cylindrospermopsin and anatoxin-a in ambient waters. The product contains step-by-step instructions for sample preparation, analyses, preservation, sample holding time and QC protocols to ensu...

  3. Bioavailability of Oral Hydrocortisone Corrected for Binding Proteins and Measured by LC-MS/MS Using Serum Cortisol and Salivary Cortisone.

    Science.gov (United States)

    Johnson, T N; Whitaker, M J; Keevil, B; Ross, R J

    2018-01-01

    The assessment absolute bioavailability of oral hydrocortisone is complicated by its saturable binding to cortisol binding globulin (CBG). Previous assessment of bioavailability used a cortisol radioimmunoassay which has cross reactivity with other steroids. Salivary cortisone is a measure of free cortisol and LC-MS/MS is the gold standard method for measuring steroids. We here report the absolute bioavailability of hydrocortisone calculated using serum cortisol and salivary cortisone measured by LC-MS/MS. 14 healthy male dexamethasone suppressed volunteers were administered 20 mg hydrocortisone either intravenously or orally by tablet. Samples of serum and saliva were taken and measured for cortisol and cortisone by LC-MS/MS. Serum cortisol was corrected for saturable binding using published data and pharmacokinetic parameters derived using the program WinNonlin. The mean (95% CI) bioavailability of oral hydrocortisone calculated from serum cortisol, unbound serum cortisol and salivary cortisone was 1.00 (0.89-1.14); 0.88 (0.75-1.05); and 0.93 (0.83-1.05), respectively. The data confirm that, after oral administration, hydrocortisone is completely absorbed. The data derived from serum cortisol corrected for protein binding, and that from salivary cortisone, are similar supporting the concept that salivary cortisone reflects serum free cortisol levels and that salivary cortisone can be used as a non-invasive method for measuring the pharmacokinetics of hydrocortisone.

  4. Developments in FT-ICR MS instrumentation, ionization techniques, and data interpretation methods for petroleomics.

    Science.gov (United States)

    Cho, Yunju; Ahmed, Arif; Islam, Annana; Kim, Sunghwan

    2015-01-01

    Because of the increasing importance of heavy and unconventional crude oil as an energy source, there is a growing need for petroleomics: the pursuit of more complete and detailed knowledge of the chemical compositions of crude oil. Crude oil has an extremely complex nature; hence, techniques with ultra-high resolving capabilities, such as Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS), are necessary. FT-ICR MS has been successfully applied to the study of heavy and unconventional crude oils such as bitumen and shale oil. However, the analysis of crude oil with FT-ICR MS is not trivial, and it has pushed analysis to the limits of instrumental and methodological capabilities. For example, high-resolution mass spectra of crude oils may contain over 100,000 peaks that require interpretation. To visualize large data sets more effectively, data processing methods such as Kendrick mass defect analysis and statistical analyses have been developed. The successful application of FT-ICR MS to the study of crude oil has been critically dependent on key developments in FT-ICR MS instrumentation and data processing methods. This review offers an introduction to the basic principles, FT-ICR MS instrumentation development, ionization techniques, and data interpretation methods for petroleomics and is intended for readers having no prior experience in this field of study. © 2014 Wiley Periodicals, Inc.

  5. Development of analytical methods for the determination of trace elements in sediment with Neutron ActivAtion method (NAA) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS)

    International Nuclear Information System (INIS)

    Nam, Sang Ho; Kim, Jae Jin; Chung, Yong Sam; Kim, Sun Ha

    2005-01-01

    The analytical methods for the determination of major elements (Al, Ca, K, Fe, Mg) in sediment have been investigated with ICP-MS. The analytical results of major elements with Cool ICP-MS were much better than those with normal ICP-MS. The analytical results were compared with those of NAA. NAA were a little superior to ICP-MS for the determination of major elements in sediment, and NAA is a non-destructive analytical method. The analytical methods for the determination of minor elements (Cr, Ce, U, Co, Pb, As, Se) in sediment have been also studied with ICP-MS. The analytical results by standard calibration with ICP-MS were not accurate due to matrix interferences. Thus, internal standard method was applied, then the analytical results for minor element with ICP-MS were greatly improved. The analytical results obtained by ICP-MS were compared with those obtained by NAA. It showed that the two analytical methods have great capabilities for the determination of minor elements in sediments

  6. UPLC-ESI-MS/MS method for the quantitative measurement of aliphatic diamines, trimethylamine N-oxide, and β-methylamino-l-alanine in human urine.

    Science.gov (United States)

    Bhandari, Deepak; Bowman, Brett A; Patel, Anish B; Chambers, David M; De Jesús, Víctor R; Blount, Benjamin C

    2018-04-15

    This work describes a quantitative high-throughput analytical method for the simultaneous measurement of small aliphatic nitrogenous biomarkers, i.e., 1,6-hexamethylenediamine (HDA), isophoronediamine (IPDA), β-methylamino-l-alanine (BMAA), and trimethylamine N-oxide (TMAO), in human urine. Urinary aliphatic diamines, HDA and IPDA, are potential biomarkers of environmental exposure to their corresponding diisocyanates. Urinary BMAA forms as a result of human exposure to blue-green algae contaminated food. And, TMAO is excreted in urine due to the consumption of carnitine- and choline-rich diets. These urinary biomarkers represent classes of small aliphatic nitrogen-containing compounds (N-compounds) that have a high aqueous solubility, low logP, and/or high basic pK a . Because of the highly polar characteristics, analysis of these compounds in complex sample matrices is often challenging. We report on the development of ion-pairing chemistry based ultra-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UPLC-ESI-MS/MS) method for the simultaneous measurement of these biomarkers in human urine. Chromatographic separation was optimized using heptafluorobutyric acid-(HFBA-) based mobile phase and a reversed-phase C18 column. All four analytes were baseline separated within 2.6 min with an overall run time of 5 min per sample injection. Sample preparation involved 4 h of acid hydrolysis followed by automated solid phase extraction (SPE) performed using strong cation exchange sorbent bed with 7 N ammonia solution in methanol as eluent. Limits of detection ranged from 0.05 ng/mL to 1.60 ng/mL. The inter-day and intra-day accuracy were within 10%, and reproducibility within 15%. The method is accurate, fast, and well-suited for biomonitoring studies within targeted groups, as well as larger population-based studies such as the U. S. National Health and Nutrition Examination Survey (NHANES). Published by Elsevier B.V.

  7. Urinary Amino Acid Analysis: A Comparison of iTRAQ®-LC-MS/MS, GC-MS, and Amino Acid Analyzer

    Science.gov (United States)

    Kaspar, Hannelore; Dettmer, Katja; Chan, Queenie; Daniels, Scott; Nimkar, Subodh; Daviglus, Martha L.; Stamler, Jeremiah; Elliott, Paul; Oefner, Peter J.

    2009-01-01

    Urinary amino acid analysis is typically done by cation-exchange chromatography followed by post-column derivatization with ninhydrin and UV detection. This method lacks throughput and specificity. Two recently introduced stable isotope ratio mass spectrometric methods promise to overcome those shortcomings. Using two blinded sets of urine replicates and a certified amino acid standard, we compared the precision and accuracy of gas chromatography/mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) of propyl chloroformate and iTRAQ® derivatized amino acids, respectively, to conventional amino acid analysis. The GC-MS method builds on the direct derivatization of amino acids in diluted urine with propyl chloroformate, GC separation and mass spectrometric quantification of derivatives using stable isotope labeled standards. The LC-MS/MS method requires prior urinary protein precipitation followed by labeling of urinary and standard amino acids with iTRAQ® tags containing different cleavable reporter ions distinguishable by MS/MS fragmentation. Means and standard deviations of percent technical error (%TE) computed for 20 amino acids determined by amino acid analyzer, GC-MS, and iTRAQ®-LC-MS/MS analyses of 33 duplicate and triplicate urine specimens were 7.27±5.22, 21.18±10.94, and 18.34±14.67, respectively. Corresponding values for 13 amino acids determined in a second batch of 144 urine specimens measured in duplicate or triplicate were 8.39±5.35, 6.23±3.84, and 35.37±29.42. Both GC-MS and iTRAQ®-LC-MS/MS are suited for high-throughput amino acid analysis, with the former offering at present higher reproducibility and completely automated sample pretreatment, while the latter covers more amino acids and related amines. PMID:19481989

  8. [Rapid screening and quality evaluation for the harmful substance 5-hydroxymethyl furfural in commercially available traditional Chinese medicine injection using LC-MS/MS method].

    Science.gov (United States)

    Zang, Qing-ce; He, Jing-jing; Bai, Jin-fa; Zheng, Ya-jie; Zhang, Rui-ping; Li, Tie-gang; Wang, Zhong-hua; He, Jiu-ming; Abliz, Zeper

    2013-11-01

    To screen the harmful substance 5-hydroxymethyl furfural content in commercially available traditional Chinese medicine injection which are commonly used, and to preliminarily evaluate the quality of these injections, 5-hydroxymethyl furfural was taken as an index. The contents of 5-hydroxymethyl furfural in 56 samples which consist of 23 kinds of traditional Chinese medicine injections and glucose injection were determined using LC-MS/MS, and 5-hydroxymethyl furfural was detected in 52 of these samples. The minimal content was 0.0038 microg x L(-1) and the maximum content was 1420 microg x mL(-1). The contents of 5-hydroxymethyl furfural were significantly different in traditional Chinese medicine injection which came from different kinds, manufacturers or batches. The results showed the quality difference of commercially available traditional Chinese medicine injection is significant taking 5-hydroxymethyl furfural content as assessment index. More attention should be paid to the safety of 5-hydroxymethyl furfural in traditional Chinese medicine injection, and unified limitation standard should be set to improve medication safety of traditional Chinese medicine injection.

  9. Fragmentation patterns involving ammonium adduct fragment ions: A comparison of the determination of metaldehyde in human blood by HPLC-QqQ-MS/MS and UHPLC-Q-TOF-MS.

    Science.gov (United States)

    Szpot, Paweł; Buszewicz, Grzegorz; Jurek, Tomasz; Teresiński, Grzegorz

    2018-05-15

    This paper presents a rapid, sensitive and precise method for the determination of metaldehyde in human blood, using ultra-performance liquid chromatography coupled with quadrupole time-of-flight tandem mass spectrometry and high-performance liquid chromatography coupled with triple quadrupole tandem mass spectrometry. Separation was performed with a Poroshell 120 EC-C18 column; 2.7 μm atrazine‑d5 (IS) and 200 mg NaCl were added to the blood sample. Proteins in human blood were precipitated using acetonitrile; the supernatant was then analyzed with the UHPLC-Q-TOF-MS or HPLC-QqQ-MS/MS system. The results of selectivity, linearity, accuracy, precision, limits of quantification, recovery, and matrix effects were sufficient to enable the measurement of metaldehyde in human blood samples. In addition, we proposed a fragmentation pathway involving ammonium adduct fragment ions for metaldehyde. Copyright © 2018. Published by Elsevier B.V.

  10. Validation Study on a Rapid Method for Simultaneous Determination of Pesticide Residues in Vegetables and Fruits by LC-MS/MS.

    Science.gov (United States)

    Sato, Tamaki; Miyamoto, Iori; Uemura, Masako; Nakatani, Tadashi; Kakutani, Naoya; Yamano, Tetsuo

    2016-01-01

    A validation study was carried out on a rapid method for the simultaneous determination of pesticide residues in vegetables and fruits by LC-MS/MS. Preparation of the test solution was performed by a solid-phase extraction technique with QuEChERS (STQ method). Pesticide residues were extracted with acetonitrile using a homogenizer, followed by salting-out and dehydration at the same time. The acetonitrile layer was purified with C18 and PSA mini-columns. The method was assessed for 130 pesticide residues in 14 kinds of vegetables and fruits at the concentration level of 0.01 μg/g according to the method validation guideline of the Ministry of Health, Labour and Welfare of Japan. As a result 75 to 120 pesticide residues were determined satisfactorily in the tested samples. Thus, this method could be useful for a rapid and simultaneous determination of multi-class pesticide residues in various vegetables and fruits.

  11. Development and validation of a simple, rapid and sensitive LC-MS/MS method for the measurement of urinary neurotransmitters and their metabolites.

    Science.gov (United States)

    Yan, Jingya; Kuzhiumparambil, Unnikrishnan; Bandodkar, Sushil; Solowij, Nadia; Fu, Shanlin

    2017-12-01

    Neurotransmitters play crucial roles in physiological functions and their imbalances have demonstrated association in the pathology of several diseases. The measurement of neurotransmitters possesses a great potential as a significant clinical tool. This study presents the development and validation of an LC-MS/MS method for simultaneous quantification of multi-class neurotransmitters associated with dopamine, tryptophan and glutamate-γ-aminobutyric acid pathways. A total of ten neurotransmitters and their metabolites (dopamine, epinephrine, metanephrine, tryptophan, serotonin, kynurenic acid, kynurenine, anthranilic acid, GABA, glutamic acid) were determined based on a simple and rapid 'dilute and shoot' method using minimal urine volume. The chromatographic separation was achieved using a Poroshell 120 Bonus-RP LC Column in combination with a gradient elution within an 8.5-min time frame. The method exhibited good sensitivity as the limits of quantification ranged between 0.025 and 0.075 μg/mL with acceptable matrix effects ( 0.98). The accuracy and precision for all analytes were within tolerances, at neurotransmitter concentrations in urine of healthy donors. Furthermore, the undertaken stability experiments indicated that acidified urine specimens allowed the analytes to be stable for prolonged durations in comparison to those untreated. The study also reveals the performance of the method is unaffected by the absence of expensive deuterated reference standards under the experimental conditions employed which further simplifies the analytical procedures and provides a significant cost saving for running the assay. Graphical abstract The quantification of multi-class neurotransitters associated with the dopamine, tryptophan and GABA-glutamate pathways using a simple 'dilute and shoot' LC-MS/MS method.

  12. Quantification of menadione from plasma and urine by a novel cysteamine-derivatization based UPLC-MS/MS method.

    Science.gov (United States)

    Yuan, Teng-Fei; Wang, Shao-Ting; Li, Yan

    2017-09-15

    Menadione, as the crucial component of vitamin Ks, possessed significant nutritional and clinical values. However, there was still lack of favourable quantification strategies for it to date. For improvement, a novel cysteamine derivatization based UPLC-MS/MS method was presented in this work. The derivatizating reaction was proved non-toxic, easy-handling and high-efficient, which realized the MS detection of menadione under positive mode. Benefitting from the excellent sensitivity of the derivatizating product as well as the introduction of the stable isotope dilution technique, the quantification could be achieved in the range of 0.05-50.0ng/mL for plasma and urine matrixes with satisfied accuracy and precision. After analysis of the samples from healthy volunteers after oral administration of menadione sodium bisulfite tablets, the urinary free menadione was quantified for the very first time. We believe the progress in this work could largely promote the exploration of the metabolic mechanism of vitamin K in vivo. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Analytical Method Details (MS): SE59_MS01 [Metabolonote[Archive

    Lifescience Database Archive (English)

    Full Text Available argeted metabolomic analysis using LC-QTOF-MS and the metabolome data processing of alignment, de-isotoping, noise cutting, and normalization was conducted as previously described. ...

  14. Natural chlorate in the environment: application of a new IC-ESI/MS/MS method with a Cl¹⁸O₃-internal standard.

    Science.gov (United States)

    Balaji Rao, Balaji Rao; Hatzinger, Paul B; Böhlke, John Karl; Sturchio, Neil C; Andraski, Brian J; Eckardt, Frank D; Jackson, W Andrew

    2010-11-15

    A new ion chromatography electrospray tandem mass spectrometry (IC-ESI/MS/MS) method has been developed for quantification and confirmation of chlorate (ClO₃⁻) in environmental samples. The method involves the electrochemical generation of isotopically labeled chlorate internal standard (Cl¹⁸O₃⁻) using ¹⁸O water (H₂¹⁸O) he standard was added to all samples prior to analysis thereby minimizing the matrix effects that are associated with common ions without the need for expensive sample pretreatments. The method detection limit (MDL) for ClO₃⁻ was 2 ng L⁻¹ for a 1 mL volume sample injection. The proposed method was successfully applied to analyze ClO₃⁻ in difficult environmental samples including soil and plant leachates. The IC-ESI/MS/MS method described here was also compared to established EPA method 317.0 for ClO₃⁻ analysis. Samples collected from a variety of environments previously shown to contain natural perchlorate (ClO₄⁻) occurrence were analyzed using the proposed method and ClO₃⁻ was found to co-occur with ClO₄⁻ at concentrations ranging from 500 mg kg⁻¹ in caliche salt deposits from the Atacama Desert in Chile. Relatively low concentrations of ClO₃⁻ in some natural groundwater samples (0.1 µg L⁻¹) analyzed in this work may indicate lower stability when compared to ClO₄⁻ in the subsurface. The high concentrations ClO₃⁻ in caliches and soils (3-6 orders of magnitude greater) as compared to precipitation samples indicate that ClO₃⁻, like ClO₄⁻, may be atmospherically produced and deposited, then concentrated in dry soils, and is possibly a minor component in the biogeochemical cycle of chlorine.

  15. Natural chlorate in the environment: Application of a new IC-ESI/MS/MS method with a Cl18O3- internal standard

    Science.gov (United States)

    Rao, Balaji; Hatzinger, Paul B.; Böhlke, John Karl; Sturchio, Neil C.; Andraski, Brian J.; Eckardt, Frank D.; Jackson, W. Andrew

    2010-01-01

    A new ion chromatography electrospray tandem mass spectrometry (IC-ESI/MS/MS) method has been developed for quantification and confirmation of chlorate (ClO3−) in environmental samples. The method involves the electro-chemical generation of isotopically labeled chlorate internal standard (Cl18O3−) using 18O water (H218O). The standard was added to all samples prior to analysis thereby minimizing the matrix effects that are associated with common ions without the need for expensive sample pretreatments. The method detection limit (MDL) for ClO3− was 2 ng L−1 for a 1 mL volume sample injection. The proposed method was successfully applied to analyze ClO3− in difficult environmental samples including soil and plant leachates. The IC-ESI/MS/MS method described here was also compared to established EPA method 317.0 for ClO3− analysis. Samples collected from a variety of environments previously shown to contain natural perchlorate (ClO4−) occurrence were analyzed using the proposed method and ClO3− was found to co-occur with ClO4− at concentrations ranging from 500 mg kg−1 in caliche salt deposits from the Atacama Desert in Chile. Relatively low concentrations of ClO3− in some natural groundwater samples (<0.1 μg L−1) analyzed in this work may indicate lower stability when compared to ClO4− in the subsurface. The high concentrations of ClO3− in caliches and soils (3−6 orders of magnitude greater) as compared to precipitation samples indicate that ClO3−, like ClO4−, may be atmospherically produced and deposited, then concentrated in dry soils, and is possibly a minor component in the biogeochemical cycle of chlorine.

  16. Determination of selected bisphenols, parabens and estrogens in human plasma using LC-MS/MS

    Czech Academy of Sciences Publication Activity Database

    Kolatorova Sosvorova, L.; Chlupacova, T.; Vitku, J.; Vlk, Martin; Heráček, J.; Stárka, L.; Šaman, David; Šimková, M.; Hampl, R.

    2017-01-01

    Roč. 174, NOV 1 (2017), s. 21-28 ISSN 0039-9140 Institutional support: RVO:61389030 ; RVO:61388963 Keywords : Alternative bisphenol * Bisphenol A * Bisphenol F * Endocrine disruptor * lc-ms/ms * Paraben Subject RIV: CC - Organic Chemistry OBOR OECD: Analytical chemistry; Organic chemistry (UOCHB-X) Impact factor: 4.162, year: 2016

  17. Development and validation of an enantioselective SFC-MS/MS method for simultaneous separation and quantification of oxcarbazepine and its chiral metabolites in beagle dog plasma.

    Science.gov (United States)

    Yang, Zhichao; Xu, Xueyu; Sun, Lingxia; Zhao, Xue; Wang, Hao; Fawcett, John Paul; Yang, Yan; Gu, Jingkai

    2016-05-01

    A rapid and sensitive assay based on supercritical fluid chromatography-tandem mass spectrometry (SFC-MS/MS) has been developed and validated for the determination of oxcarbazepine (OXC) and its chiral metabolite licarbazine (Lic) in beagle dog plasma using carbamazepine as internal standard. Chiral analysis in a run time of only 3 min was performed on an ACQUITY UPC(2) ™ Trefoil™ CEL2 column (3.0 × 150 mm, 2.5 μm) at 50 °C by isocratic elution with a mobile phase of supercritical carbon dioxide (purity ≥ 99.99%) and methanol (60:40, v/v) at a flow rate of 2.3 mL/min. The assay was linear over the concentration ranges 5-1000 ng/mL for OXC and 0.5-100 ng/mL for the enantiomers of Lic with corresponding lower limits of quantitation of 5 ng/mL and 0.5 ng/mL. Intra- and inter-day precisions were in the range 0.78-14.14% with accuracies in the range -10.80% to 0.42%. The method was successfully applied to a pharmacokinetic study involving a single oral administration of 16 mg/kg OXC as Trileptal(@) tablets to beagle dogs. Copyright © 2016. Published by Elsevier B.V.

  18. A laser ablation ICP-MS based method for multiplexed immunoblot analysis

    DEFF Research Database (Denmark)

    de Bang, Thomas Christian; Petersen, Jørgen; Pedas, Pai Rosager

    2015-01-01

    developed a multiplexed antibody-based assay and analysed selected PSII subunits in barley (Hordeum vulgare L.). A selection of antibodies were labelled with specific lanthanides and immunoreacted with thylakoids exposed to Mn deficiency after western blotting. Subsequently, western blot membranes were...... analysed by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), which allowed selective and relative quantitative analysis via the different lanthanides. The method was evaluated against established liquid chromatography electrospray ionization tandem mass spectrometry (LC...... by more than one technique. The developed method enables a higher number of proteins to be multiplexed in comparison to existing immunoassays. Furthermore, multiplexed protein analysis by LA-ICP-MS provides an analytical platform with high throughput appropriate for screening large collections of plants....

  19. Analysis of corrosion-product transport using nondestructive XRF and MS techniques

    International Nuclear Information System (INIS)

    Sawicka, B.D.; Sawicki, J.A.

    1998-01-01

    This paper describes the application of X-ray fluorescence (XRF) and Moessbauer spectroscopy (MS) techniques to monitor corrosion-product transport (CPT) in water circuits of nuclear reactors. The combination of XRF and MS techniques was applied in studies of CPT crud filters from both primary- and secondary-side water circuits (i.e., radioactive and nonradioactive specimens) of CANDU reactors. The XRF-MS method allows nondestructive analysis of species collected on filters and provides more complete information about corrosion products than commonly used digestive methods of chemical analysis. Recent analyses of CPT specimens from the Darlington Nuclear Generating Station (NGS) primary side and the Bruce B NGS feedwater system are shown as examples. Some characteristics of primary and secondary water circuits are discussed using these new data. (author)

  20. Contribution to the development of new analytical methods by the coupling between capillary electrophoresis and mass spectrometry (ICP-MS and ESI-MS): applications to the nuclear and biological fields

    International Nuclear Information System (INIS)

    Pitois, A.

    2006-04-01

    The coupling between chromatographic and electrophoretic separation techniques and mass spectrometry is used to combine the efficiency of the separation technique to the selectivity and sensitivity of the detectors. In this work, the number of applications of the CE-MS couplings has been increased. New analytical methods have been set up in the nuclear and biological fields. New analytical methods for the determination of fission products (cesium and lanthanides) have been developed by CE-ICP-MS. They enable to determine both concentration and isotopic composition of the fission products for very low detection limits (ng/mL by CE-Q-ICPMS, pg/mL by CE-HR-ICP-MS), since all the isobaric interferences are resolved. Moreover, only some nano-liters of sample are necessary to perform the analysis. These method have been applied with success to a simulated sample of spent fuel, to a nuclear sample from PUREX process and to a leaching of MOX fuel. Then, lanthanides have been analysed by CE-ESI-MS and the capability of ESI-MS to provide structural information has been studied. Elementary information has been obtained for strong potentials. Structural information has been obtained for low potentials. Finally, a new analytical method by CE-ESI-MS for the determination of 10B-boronophenylalanine (10B-BPA) has been developed for Boron Neutron Capture Therapy (BNCT). It has been applied to the cellular lines F98 and HUVEC. This CE-ESI-MS method has been validated by HR-ICP-MS. It enables a direct quantification of the chemical form 10B-BPA in samples of limited size (some nano-liters) and for low concentrations (ng/mL). As a consequence, this CE-ESI-MS method has enabled the study of the kinetics of 10B-BPA release and uptake for the F98 cells. (author)

  1. A New Multielement Method for LA-ICP-MS Data Acquisition from Glacier Ice Cores.

    Science.gov (United States)

    Spaulding, Nicole E; Sneed, Sharon B; Handley, Michael J; Bohleber, Pascal; Kurbatov, Andrei V; Pearce, Nicholas J; Erhardt, Tobias; Mayewski, Paul A

    2017-11-21

    To answer pressing new research questions about the rate and timing of abrupt climate transitions, a robust system for ultrahigh-resolution sampling of glacier ice is needed. Here, we present a multielement method of LA-ICP-MS analysis wherein an array of chemical elements is simultaneously measured from the same ablation area. Although multielement techniques are commonplace for high-concentration materials, prior to the development of this method, all LA-ICP-MS analyses of glacier ice involved a single element per ablation pass or spot. This new method, developed using the LA-ICP-MS system at the W. M. Keck Laser Ice Facility at the University of Maine Climate Change Institute, has already been used to shed light on our flawed understanding of natural levels of Pb in Earth's atmosphere.

  2. Validation of UHPLC-MS/MS methods for the determination of kaempferol and its metabolite 4-hydroxyphenyl acetic acid, and application to in vitro blood-brain barrier and intestinal drug permeability studies.

    Science.gov (United States)

    Moradi-Afrapoli, Fahimeh; Oufir, Mouhssin; Walter, Fruzsina R; Deli, Maria A; Smiesko, Martin; Zabela, Volha; Butterweck, Veronika; Hamburger, Matthias

    2016-09-05

    Sedative and anxiolytic-like properties of flavonoids such as kaempferol and quercetin, and of some of their intestinal metabolites, have been demonstrated in pharmacological studies. However, routes of administration were shown to be critical for observing in vivo activity. Therefore, the ability to cross intestinal and blood-brain barriers was assessed in cell-based models for kaempferol (KMF), and for the major intestinal metabolite of KMF, 4-hydroxyphenylacetic acid (4-HPAA). Intestinal transport studies were performed with Caco-2 cells, and blood-brain barrier transport studies with an immortalized monoculture human model and a primary triple-co-culture rat model. UHPLC-MS/MS methods for KMF and 4-HPAA in Ringer-HEPES buffer and in Hank's balanced salt solution were validated according to industry guidelines. For all methods, calibration curves were fitted by least-squares quadratic regression with 1/X(2) as weighing factor, and mean coefficients of determination (R(2)) were >0.99. Data obtained with all barrier models showed high intestinal and blood-brain barrier permeation of KMF, and no permeability of 4-HPAA, when compared to barrier integrity markers. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Development of an SPME-GC-MS/MS method for the determination of pesticides in rainwater: Laboratory and field experiments

    International Nuclear Information System (INIS)

    Sauret-Szczepanski, Nathalie; Mirabel, Philippe; Wortham, Henri

    2006-01-01

    A solid-phase microextraction - coupled to a gas chromatography - ion trap tandem mass spectrometry (SPME-GC-MS/MS) method was developed for the quantitative determination in rainwater of 8 pesticides amongst the most used in France and 3 triazines metabolites. The main factors affecting the SPME process were studied. Using a 3 mL sample, the method developed showed good linearity for concentrations ranging from 0.05 to 50 μg L -1 with correlation coefficients between 0.997 and 0.9999 and relative standard deviations (% RSD) below 14%. The study of matrix effects showed that rainwater was too diluted to have any significant influence on the extraction efficiency. To validate the method, a field campaign was carried out on the rain events, which occurred in Strasbourg during a one-year period. The rain concentrations showed patterns of high pesticide concentrations during spring months, which were correlated to the spraying periods of most of these substances. - Solid-phase microextraction efficiency of pesticides in rainwater was optimized

  4. Selenium speciation analysis of Misgurnus anguillicaudatus selenoprotein by HPLC-ICP-MS and HPLC-ESI-MS/MS

    Science.gov (United States)

    Analytical methods for selenium (Se) speciation were developed using high performance liquid chromatography (HPLC) coupled to either inductively coupled plasma mass spectrometry (ICP-MS) or electrospray ionization tandem mass spectrometry (ESI-MS/MS). Separations of selenomethionine (Se-Met) and sel...

  5. Development and validation of LC-MS/MS method for the determination of Ochratoxin A and its metabolite Ochratoxin α in poultry tissues and eggs.

    Science.gov (United States)

    Paoloni, Angela; Solfrizzo, Michele; Bibi, Rita; Pecorelli, Ivan

    2018-05-04

    The objective of this study was to develop a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the determination of Ochratoxin A (OTA) and Ochratoxin α (OTα) in poultry tissues and eggs. The two toxins were extracted by a mixture of acetonitrile/water, purified with a reversed phase C18 solid phase extraction column (SPE) and determined by LC-MS/MS. The LC-MS/MS method performances were evaluated in terms of linearity in solvent and in matrix (ranged from 0.5 to 15.10 µg L -1 for OTA and from 0.60 to 17.85 µg L -1 for OTα), limit of detection (LOD), limit of quantitation (LOQ), specificity, accuracy and precision in repeatability conditions. Recovery experiments were performed by spiking poultry liver, kidney, muscle and eggs around 1 µg kg -1 and 10 µg kg -1 . LODs were 0.27 and 0.26 µg kg -1 while LOQs were fixed at 1.0 and 1.2 µg kg -1 for OTA and OTα, respectively. Main recoveries for OTA ranged from 82 to 109% and for OTα ranged from 55 to 89%. The values of within-laboratory relative standard deviation (RSD r ) were equal to or below 20%. Considering the results obtained and that all analytical performance criteria were fulfilled, the new extraction and purification method developed for OTA and OTα determination in animal tissues and eggs was found appropriate for control laboratories and research activities designed to ensure food safety.

  6. Two simple cleanup methods combined with LC-MS/MS for quantification of steroid hormones in in vivo and in vitro assays

    DEFF Research Database (Denmark)

    Weisser, Johan Juhl; Hansen, Cecilie Hurup; Poulsen, Rikke

    2016-01-01

    Measuring both progestagens, androgens, corticosteroids as well as estrogens with a single method makes it possible to investigate the effects of endocrine-disrupting chemicals (EDCs) on the main pathways in the mammalian steroidogenesis. This paper presents two simple methods for the determination...... of the major steroid hormones in biological matrixes using liquid chromatography tandem mass spectrometry (LC-MS(2)). A novel method was developed for the determination of 14 steroids in the H295R in vitro assay without the need for solid phase extraction (SPE) purification prior to LC-MS(2) analysis....... The in vitro assay was validated by exposing H295R cells to prochloraz for inhibiting steroid hormone secretion and by exposing cells to forskolin for inducing steroid hormone secretion. The developed method fulfills the recommendations for the H295R assay suggested by the OECD. Furthermore, a simple off...

  7. Evaluation of a Method for Nitrotyrosine Site Identification and Relative Quantitation Using a Stable Isotope-Labeled Nitrated Spike-In Standard and High Resolution Fourier Transform MS and MS/MS Analysis

    Directory of Open Access Journals (Sweden)

    Kent W. Seeley

    2014-04-01

    Full Text Available The overproduction of reactive oxygen and nitrogen species (ROS and RNS can have deleterious effects in the cell, including structural and possible activity-altering modifications to proteins. Peroxynitrite is one such RNS that can result in a specific protein modification, nitration of tyrosine residues to form nitrotyrosine, and to date, the identification of nitrotyrosine sites in proteins continues to be a major analytical challenge. We have developed a method by which 15N-labeled nitrotyrosine groups are generated on peptide or protein standards using stable isotope-labeled peroxynitrite (O15NOO−, and the resulting standard is mixed with representative samples in which nitrotyrosine formation is to be measured by mass spectrometry (MS. Nitropeptide MS/MS spectra are filtered using high mass accuracy Fourier transform MS (FTMS detection of the nitrotyrosine immonium ion. Given that the nitropeptide pair is co-isolated for MS/MS fragmentation, the nitrotyrosine immonium ions (at m/z = 181 or 182 can be used for relative quantitation with negligible isotopic interference at a mass resolution of greater than 50,000 (FWHM, full width at half-maximum. Furthermore, the standard potentially allows for the increased signal of nitrotyrosine-containing peptides, thus facilitating selection for MS/MS in a data-dependent mode of acquisition. We have evaluated the methodology in terms of nitrotyrosine site identification and relative quantitation using nitrated peptide and protein standards.

  8. Processing methods for differential analysis of LC/MS profile data

    Directory of Open Access Journals (Sweden)

    Orešič Matej

    2005-07-01

    Full Text Available Abstract Background Liquid chromatography coupled to mass spectrometry (LC/MS has been widely used in proteomics and metabolomics research. In this context, the technology has been increasingly used for differential profiling, i.e. broad screening of biomolecular components across multiple samples in order to elucidate the observed phenotypes and discover biomarkers. One of the major challenges in this domain remains development of better solutions for processing of LC/MS data. Results We present a software package MZmine that enables differential LC/MS analysis of metabolomics data. This software is a toolbox containing methods for all data processing stages preceding differential analysis: spectral filtering, peak detection, alignment and normalization. Specifically, we developed and implemented a new recursive peak search algorithm and a secondary peak picking method for improving already aligned results, as well as a normalization tool that uses multiple internal standards. Visualization tools enable comparative viewing of data across multiple samples. Peak lists can be exported into other data analysis programs. The toolbox has already been utilized in a wide range of applications. We demonstrate its utility on an example of metabolic profiling of Catharanthus roseus cell cultures. Conclusion The software is freely available under the GNU General Public License and it can be obtained from the project web page at: http://mzmine.sourceforge.net/.

  9. Evaluation of Normalization Methods to Pave the Way Towards Large-Scale LC-MS-Based Metabolomics Profiling Experiments

    Science.gov (United States)

    Valkenborg, Dirk; Baggerman, Geert; Vanaerschot, Manu; Witters, Erwin; Dujardin, Jean-Claude; Burzykowski, Tomasz; Berg, Maya

    2013-01-01

    Abstract Combining liquid chromatography-mass spectrometry (LC-MS)-based metabolomics experiments that were collected over a long period of time remains problematic due to systematic variability between LC-MS measurements. Until now, most normalization methods for LC-MS data are model-driven, based on internal standards or intermediate quality control runs, where an external model is extrapolated to the dataset of interest. In the first part of this article, we evaluate several existing data-driven normalization approaches on LC-MS metabolomics experiments, which do not require the use of internal standards. According to variability measures, each normalization method performs relatively well, showing that the use of any normalization method will greatly improve data-analysis originating from multiple experimental runs. In the second part, we apply cyclic-Loess normalization to a Leishmania sample. This normalization method allows the removal of systematic variability between two measurement blocks over time and maintains the differential metabolites. In conclusion, normalization allows for pooling datasets from different measurement blocks over time and increases the statistical power of the analysis, hence paving the way to increase the scale of LC-MS metabolomics experiments. From our investigation, we recommend data-driven normalization methods over model-driven normalization methods, if only a few internal standards were used. Moreover, data-driven normalization methods are the best option to normalize datasets from untargeted LC-MS experiments. PMID:23808607

  10. Development of a LC-MS/MS method for the simultaneous screening of seven water-soluble vitamins in processing semi-coarse wheat flour products.

    Science.gov (United States)

    Nurit, Eric; Lyan, Bernard; Piquet, Agnès; Branlard, Gérard; Pujos-Guillot, Estelle

    2015-05-01

    Wheat is the second largest crop cultivated around the world and constitutes a major part of the daily diet in Europe. It is therefore important to determine the content of micronutrient in wheat and wheat-based food products to define the contribution of wheat-based foods to the nutrition of the consumers. The aim of the present work was to develop a simple and rapid method based on liquid chromatography tandem mass spectrometry (LC-MS/MS) for the simultaneous determination of seven water-soluble vitamins in various wheat-based food materials. The vitamins present in the test material were separated in less than 15 min by using a reverse-phase C18 column, and analyzed by positive ion electrospray selected reaction monitoring MS/MS. The MS response for all the vitamins was linear over the working range (0.05 to 9 μg/mL) with correlation coefficients ranging between 0.991 and 1. Limits of quantification in the different food materials ranged from 0.09 to 3.5 μg/g. Intra-day and inter-day precision were found satisfactory. The developed method was applied for the simultaneous analysis of the water-soluble vitamin natural content of different semi-coarse wheat flours and in their corresponding baking products.

  11. NMR and MS methods for metabonomics.

    Science.gov (United States)

    Dieterle, Frank; Riefke, Björn; Schlotterbeck, Götz; Ross, Alfred; Senn, Hans; Amberg, Alexander

    2011-01-01

    Metabonomics, also often referred to as "metabolomics" or "metabolic profiling," is the systematic profiling of metabolites in bio-fluids or tissues of organisms and their temporal changes. In the last decade, metabonomics has become increasingly popular in drug development, molecular medicine, and other biotechnology fields, since it profiles directly the phenotype and changes thereof in contrast to other "-omics" technologies. The increasing popularity of metabonomics has been possible only due to the enormous development in the technology and bioinformatics fields. In particular, the analytical technologies supporting metabonomics, i.e., NMR, LC-MS, UPLC-MS, and GC-MS have evolved into sensitive and highly reproducible platforms allowing the determination of hundreds of metabolites in parallel. This chapter describes the best practices of metabonomics as seen today. All important steps of metabolic profiling in drug development and molecular medicine are described in great detail, starting from sample preparation, to determining the measurement details of all analytical platforms, and finally, to discussing the corresponding specific steps of data analysis.

  12. Development of an Efficient Protein Extraction Method Compatible with LC-MS/MS for Proteome Mapping in Two Australian Seagrasses Zostera muelleri and Posidonia australis

    Directory of Open Access Journals (Sweden)

    Zhijian Jiang

    2017-08-01

    Full Text Available The availability of the first complete genome sequence of the marine flowering plant Zostera marina (commonly known as seagrass in early 2016, is expected to significantly raise the impact of seagrass proteomics. Seagrasses are marine ecosystem engineers that are currently declining worldwide at an alarming rate due to both natural and anthropogenic disturbances. Seagrasses (especially species of the genus Zostera are compromised for proteomic studies primarily due to the lack of efficient protein extraction methods because of their recalcitrant cell wall which is rich in complex polysaccharides and a high abundance of secondary metabolites in their cells. In the present study, three protein extraction methods that are commonly used in plant proteomics i.e., phenol (P; trichloroacetic acid/acetone/SDS/phenol (TASP; and borax/polyvinyl-polypyrrolidone/phenol (BPP extraction, were evaluated quantitatively and qualitatively based on two dimensional isoelectric focusing (2D-IEF maps and LC-MS/MS analysis using the two most abundant Australian seagrass species, namely Zostera muelleri and Posidonia australis. All three tested methods produced high quality protein extracts with excellent 2D-IEF maps in P. australis. However, the BPP method produces better results in Z. muelleri compared to TASP and P. Therefore, we further modified the BPP method (M-BPP by homogenizing the tissue in a modified protein extraction buffer containing both ionic and non-ionic detergents (0.5% SDS; 1.5% Triton X-100, 2% PVPP and protease inhibitors. Further, the extracted proteins were solubilized in 0.5% of zwitterionic detergent (C7BzO instead of 4% CHAPS. This slight modification to the BPP method resulted in a higher protein yield, and good quality 2-DE maps with a higher number of protein spots in both the tested seagrasses. Further, the M-BPP method was successfully utilized in western-blot analysis of phosphoenolpyruvate carboxylase (PEPC—a key enzyme for carbon

  13. Enantioselective analysis of citalopram and demethylcitalopram in human whole blood by chiral LC-MS/MS and application in forensic cases

    DEFF Research Database (Denmark)

    Johansen, Sys Stybe

    2017-01-01

    OH. The analytes were separated on a 250 x 4.6 mm Chirobiotic V, 5 µm column by isocratic elution with methanol:ammonia:acetic acid (1000:1:1) using an ultra-high-pressure liquid chromatography (UHPLC) system. Quantification was performed by tandem mass spectrometry (MS/MS) using multiple reaction monitoring...... in the positive mode. The total chromatographic run time was 20 min. The limit of detection (LOD) and quantification (LOQ) were 0.001 and 0.005 mg/kg of all four enantiomers, respectively. Linear behaviour was obtained for all four enantiomers from LOQ to 0.50 mg/kg blood with absolute recoveries from 71 to 80......%. The method showed an acceptable precision and accuracy as the obtained coefficient of variation, and bias values were ≤ 16% for all enantiomers. After the validation of the method, a correlation with the racemic method was assessed and found to be acceptable. Then, the method was successfully applied...

  14. Validation of an semi-automated multi component method using protein precipitation LC-MS-MS for the analysis of whole blood samples

    DEFF Research Database (Denmark)

    Slots, Tina

    BACKGROUND: Solid phase extraction (SPE) are one of many multi-component methods, but can be very time-consuming and labour-intensive. Protein precipitation is, on the other hand, a much simpler and faster sample pre-treatment than SPE, and protein precipitation also has the ability to cover a wi......-mortem whole blood sample preparation for toxicological analysis; from the primary sample tube to a 96-deepwell plate ready for injection on the liquid chromatography mass spectrometry (LC-MS/MS)....

  15. A validated UPLC-MS/MS method for the analysis of linezolid and a novel oxazolidinone derivative (PH027) in plasma and its application to tissue distribution study in rabbits.

    Science.gov (United States)

    Hedaya, Mohsen A; Thomas, Vidhya; Abdel-Hamid, Mohamed E; Kehinde, Elijah O; Phillips, Oludotun A

    2017-01-01

    Linezolid is the first approved oxazolidinone antibacterial agent, whereas PH027 is a novel compound of the same class that exhibits good in vitro antibacterial activity. The objective of this study was to develop an UPLC-MS/MS assay for the analysis of linezolid and PH027 in plasma and to apply the method for comparative pharmacokinetic and tissue distribution studies of both compounds. Plasma samples and calibrators were extracted with diethyl ether after addition of the internal standard solution. After evaporation of the ether layer, the residue was reconstituted in mobile phase and injected into UPLC-MS/MS. The mobile phase consisted of 2mM ammonium acetate buffer solution and acetonitrile (70:30) at a flow rate of 0.2ml/min. Separation was achieved using UPLC BEH C 18 column, and quantitative determination of the analytes was performed using multiple-reaction monitoring (MRM) scanning mode. The method was validated by analyzing quality control tissue homogenate samples, and was applied to analyze tissue homogenate samples obtained following IV injections of linezolid and PH027 in rabbits. The developed UPLC-MS/MS method was linear in the concentration range of 50-5000ng/ml. Validation of the method proved that the method's precision, selectivity and stability were all within the acceptable limits. Linezolid and PH027 concentrations were accurately determined in the quality control tissue homogenate samples, and analysis of samples obtained following IV administration of the two compounds showed that the tissue to plasma concentration ratio of PH027 was higher than that of linezolid probably due to its higher lipophilicity. The developed UPLC-MS/MS method for the analysis of linezolid and PH027 in rabbit's plasma can accurately determine the concentrations of these compounds in different tissues. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. LC-MS/MS method for the determination of clodronate in human plasma.

    Science.gov (United States)

    Hasan, Mahmoud; Schumacher, Gitta; Seekamp, Anne; Taedken, Tobias; Siegmund, Werner; Oswald, Stefan

    2014-11-01

    Clodronate belongs to the class of bisphosphonates which are used for the treatment of bone disorders. Due to its high polarity it has a low and highly variable oral bioavailability which results in low plasma concentrations and requires sensitive bioanalytical methods to characterize its pharmacokinetics in human. Here, we describe for the first time the development and validation of a LC-MS/MS assay for the quantification of clodronate in human plasma. The bisphosphonate was isolated from the biological matrix by protein precipitation using perchloric acid (10%), and derivatized with trimethylorthoacetate prior sample clean-up with liquid-liquid extraction using methyl tert-butyl ether. The chromatography was performed using an isocratic elution with ammonium acetate 5mM (85% v/v, pH 3.8) and acetonitrile (15% v/v) as mobile phase with a flow rate of 300μl/min on a reversed-phase column (Supelco Ascentis(®), C18) temporized at 50°C. The mass spectrometric detection was done using the API4000 triple quadruple mass spectrometer monitoring the mass/charge transitions 301.0/145 for clodronate and 305.2/137.1 for the internal standard etidronate. The analytical range was set to 5-800ng/ml, allowing an evaluation of the plasma concentration-time profiles of clodronate for approximately 7-8 half-life (∼24h). The method was validated according to current FDA/EMA guidelines on bioanalytical method validation with respect to specificity, linearity, intra- and inter-day accuracy and precision, matrix effect, recovery as well as stability. The precision of the assay was 0.6-6.9% and 0.6-8.1% for the intra-day and inter-day variability, respectively. The intra-day and inter-day accuracy (error) was 0.6-8.8% and 2.2-4.5%. The recovery of the analyte was low (2-3%) but reproducible over the entire validation range and sufficient to monitor the target concentrations in human plasma. The drug was shown to be stable in plasma at room temperature for at least 3h (96.0±6%) and

  17. LC-MS/MS method for simultaneous determination of thalidomide, lenalidomide, cyclophosphamide, bortezomib, dexamethasone and adriamycin in serum of multiple myeloma patients.

    Science.gov (United States)

    Shu, Chang; Zeng, Tianmei; Gao, Shouhong; Xia, Tianyi; Huang, Lifeng; Zhang, Feng; Chen, Wansheng

    2016-08-15

    Multiple myeloma (MM), a malignant neoplastic serum-cell disorder, has been a serious threat to human health. The determination of 6 commonly used drug concentrations, including thalidomide, lenalidomide, cyclophosphamide, bortezomib, dexamethasone and adriamycin, in MM patients was of great clinical interest. Herein, we reported a method for the rapid and simultaneous measurement of the above therapeutics by liquid chromatography-tandem mass spectroscopy (LC-MS/MS) method with solid phase extraction. Analysis was performed on a Waters XBridge(®) BEH C18 column (2.5μm, 2.1 mm×50mm), with formic acid aqueous solution and acetonitrile as the mobile phase at flow rate 0.3mL/min. All analytes showed good correlation coefficients (r>0.996), and LLOQ of thalidomide, lenalidomide, cyclophosphamide, bortezomib, dexamethasone and adriamycin were 4, 2, 2, 2, 2 and 2ng/mL, respectively. The inter- and intra-day precisions and stability were expressed as variation coefficients within 15% and relative error less than 15%. Dilution effect, carryover and incurred sample reanalysis were investigated according to the 2015 edition Chinese Pharmacopoeia guidelines, as US FDA (2013, revision 1) required. The LC-MS/MS based assay described in this article may improve future clinical studies evaluating common therapeutics for MM treatment. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Screening natural antioxidants in peanut shell using DPPH-HPLC-DAD-TOF/MS methods.

    Science.gov (United States)

    Qiu, Jiying; Chen, Leilei; Zhu, Qingjun; Wang, Daijie; Wang, Wenliang; Sun, Xin; Liu, Xiaoyong; Du, Fangling

    2012-12-15

    Peanut shell, a byproduct in oil production, is rich in natural antioxidants. Here, a rapid and efficient method using DPPH-HPLC-DAD-TOF/MS was used for the first time to screen antioxidants in peanut shell. The method is based on the hypothesis that upon reaction with 1, 1-diphenyl-2-picrylhydrazyl (DPPH), the peak areas of compounds with potential antioxidant activities in the HPLC chromatogram will be significantly reduced or disappeared, and the identity confirmation could be achieved by HPLC-DAD-TOF/MS technique. With this method, three compounds possessing potential antioxidant activities were found abundantly in the methanolic extract of peanut shell. They were identified as 5,7-dihydroxychromone, eriodictyol, and luteolin. The contents of these compounds were 0.59, 0.92, and 2.36 mg/g, respectively, and luteolin possessed the strongest radical scavenging capacity. DPPH-HPLC-DAD-TOF/MS assay facilitated rapid identification and determination of natural antioxidants in peanut shell, which may be helpful for value-added utilization of peanut processing byproducts. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Screening for anabolic steroids in urine of forensic cases using fully automated solid phase extraction and LC-MS-MS.

    Science.gov (United States)

    Andersen, David W; Linnet, Kristian

    2014-01-01

    A screening method for 18 frequently measured exogenous anabolic steroids and the testosterone/epitestosterone (T/E) ratio in forensic cases has been developed and validated. The method involves a fully automated sample preparation including enzyme treatment, addition of internal standards and solid phase extraction followed by analysis by liquid chromatography-tandem mass spectrometry (LC-MS-MS) using electrospray ionization with adduct formation for two compounds. Urine samples from 580 forensic cases were analyzed to determine the T/E ratio and occurrence of exogenous anabolic steroids. Extraction recoveries ranged from 77 to 95%, matrix effects from 48 to 78%, overall process efficiencies from 40 to 54% and the lower limit of identification ranged from 2 to 40 ng/mL. In the 580 urine samples analyzed from routine forensic cases, 17 (2.9%) were found positive for one or more anabolic steroids. Only seven different steroids including testosterone were found in the material, suggesting that only a small number of common steroids are likely to occur in a forensic context. The steroids were often in high concentrations (>100 ng/mL), and a combination of steroids and/or other drugs of abuse were seen in the majority of cases. The method presented serves as a fast and automated screening procedure, proving the suitability of LC-MS-MS for analyzing anabolic steroids. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Rapid method for quantification of seven synthetic pigments in colored Chinese steamed buns using UFLC-MS/MS without SPE.

    Science.gov (United States)

    Gao, He-Gang; Gong, Wen-Jie; Zhao, Yong-Gang

    2015-01-01

    Synthetic pigments are still used instead of natural pigments in many foods and their residues in food could be an important risk to human health. A simple and rapid analytical method combining the low-cost extraction protocol with ultra-fast liquid chromatography-tandem quadrupole mass spectrometry (UFLC-MS/MS) was developed for the simultaneous determination of seven synthetic pigments used in colored Chinese steamed buns. For the first time, ethanol/ammonia solution/water (7:2:1, v/v/v) was used as extraction solution for the synthetic pigments in colored Chinese steamed buns. The results showed that the property of the extraction solution used in this method was more effective than critic acid solution, which is used in the polyamide adsorption method. The limits of quantification for the seven synthetic pigments ranged from 0.15 to 0.50 μg/kg. The present method was successfully applied to samples of colored Chinese steamed buns for food-safety risk monitoring in Zhejiang Province, China. The results found sunset yellow pigment in six out of 300 colored Chinese steamed buns (from 0.50 to 32.6 μg/kg).

  1. Efficient analysis and extraction of MS/MS result data from Mascot™ result files

    Directory of Open Access Journals (Sweden)

    Sickmann Albert

    2005-12-01

    Full Text Available Abstract Background Mascot™ is a commonly used protein identification program for MS as well as for tandem MS data. When analyzing huge shotgun proteomics datasets with Mascot™'s native tools, limits of computing resources are easily reached. Up to now no application has been available as open source that is capable of converting the full content of Mascot™ result files from the original MIME format into a database-compatible tabular format, allowing direct import into database management systems and efficient handling of huge datasets analyzed by Mascot™. Results A program called mres2x is presented, which reads Mascot™ result files, analyzes them and extracts either selected or all information in order to store it in a single file or multiple files in formats which are easier to handle downstream of Mascot™. It generates different output formats. The output of mres2x in tab format is especially designed for direct high-performance import into relational database management systems using native tools of these systems. Having the data available in database management systems allows complex queries and extensive analysis. In addition, the original peak lists can be extracted in DTA format suitable for protein identification using the Sequest™ program, and the Mascot™ files can be split, preserving the original data format. During conversion, several consistency checks are performed. mres2x is designed to provide high throughput processing combined with the possibility to be driven by other computer programs. The source code including supplement material and precompiled binaries is available via http://www.protein-ms.de and http://sourceforge.net/projects/protms/. Conclusion The database upload allows regrouping of the MS/MS results using a database management system and complex analyzing queries using SQL without the need to run new Mascot™ searches when changing grouping parameters.

  2. Analytical Method Details (MS): SE53_MS01 [Metabolonote[Archive

    Lifescience Database Archive (English)

    Full Text Available .25-μl film Rtx-5 Sil MS stationary phase (RESTEK, Bellefonte, USA) for metabolome... analysis. Helium was used as the carrier gas at a constant flow rate of 1 ml min-1. The temperature program for metabolome

  3. DBS-LC-MS/MS assay for caffeine: validation and neonatal application.

    Science.gov (United States)

    Bruschettini, Matteo; Barco, Sebastiano; Romantsik, Olga; Risso, Francesco; Gennai, Iulian; Chinea, Benito; Ramenghi, Luca A; Tripodi, Gino; Cangemi, Giuliana

    2016-09-01

    DBS might be an appropriate microsampling technique for therapeutic drug monitoring of caffeine in infants. Nevertheless, its application presents several issues that still limit its use. This paper describes a validated DBS-LC-MS/MS method for caffeine. The results of the method validation showed an hematocrit dependence. In the analysis of 96 paired plasma and DBS clinical samples, caffeine levels measured in DBS were statistically significantly lower than in plasma but the observed differences were independent from hematocrit. These results clearly showed the need for extensive validation with real-life samples for DBS-based methods. DBS-LC-MS/MS can be considered to be a good alternative to traditional methods for therapeutic drug monitoring or PK studies in preterm infants.

  4. Development of an Analytical Method for Analyzing Pyrrolizidine Alkaloids in Different Groups of Food by UPLC-MS/MS.

    Science.gov (United States)

    Chung, Stephen W C; Lam, Chi-Ho

    2018-03-21

    Suspected nontargeted pyrrolizidine alkaloids (PAs), without analytical reference standard, were observed and interfered with the determination of targeted PAs in complex food matrices, especially for spices samples. Selectivity and applicability of multiple reaction monitoring (MRM) transitions, multistage fragmentation (MS3), and MRM with differential ion mobility spectrometry (DMS) for eliminating false positive identifications were evaluated. Afterward, a selective and sensitive LC-MS/MS method for the determination of 15 PAs and 13 PA N-oxides in foodstuffs was developed. The sample preparation and cleanup are applicable to a wide range of foodstuffs, including cereal products, dairy products, meat, eggs, honey, tea infusion, and spices. Freezing-out of the raw extract and the water/acetonitrile washing steps in a solid phase extraction was found to efficiently remove complex matrices. The method was validated at 0.05 μg kg -1 for general food and 0.5 μg kg -1 for spices, with reference to the Eurachem Guide. The estimated limit of quantifications of different PAs was in the range of 0.010-0.087 μg kg -1 for general food and 0.04-0.76 μg kg -1 for spices. Isotopically labeled PAs were used as internal standards to correct the variation of PAs/PANs performance in different food commodities. Matrix effects observed in complex food matrices could be reduced by solvent dilution. Recoveries of PAs and PA N-oxides were all seen within 50-120%.

  5. Development and Validation of a UPLC-MS/MS and UPLC-HR-MS Method for the Determination of Fumonisin B1 and Its Hydrolysed Metabolites and Fumonisin B2 in Broiler Chicken Plasma

    Directory of Open Access Journals (Sweden)

    Siegrid De Baere

    2018-01-01

    Full Text Available A sensitive and specific method for the quantitative determination of Fumonisin B1 (FB1, its partially hydrolysed metabolites pHFB1a+b and hydrolysed metabolite HFB1, and Fumonisin B2 (FB2 in broiler chicken plasma using ultra-performance liquid chromatography combined with tandem mass spectrometry (UPLC-MS/MS was developed. The sample preparation was rapid, straightforward and consisted of a deproteinization and phospholipid removal step using an Oasis® OstroTM 96-well plate. Chromatography was performed on an Acquity HSS-T3 column, using 0.3% formic acid and 10 mM ammonium formate in water, and acetonitrile as mobile phases. The MS/MS instrument was operated in the positive electrospray ionization mode and the two multiple reaction monitoring transitions were monitored for each component for quantification and identification, respectively. The method was validated in-house: matrix-matched calibration graphs were prepared and good linearity (r ≥ 0.99 was achieved over the concentration ranges tested (1–500 ng/mL for FB1 and FB2; 0.86–860 ng/mL for pHFB1a; 0.72–1430 ng/mL for pHFB1b and 2.5–2500 ng/mL for HFB1. Limits of quantification (LOQ and detection (LOD in plasma ranged between 0.72 to 2.5 ng/mL and 0.03 to 0.17 ng/mL, respectively. The results for the within-day and between-day precision and accuracy fell within the specified ranges. Moreover, the method was transferred to an UPLC high-resolution mass spectrometry (HR-MS instrument in order to determine potential metabolites of HFB1, such as N-acyl-HFB1s and phase II metabolites. The method has been successfully applied to investigate the toxicokinetics and biotransformation of HFB1 in broiler chickens.

  6. Evaluation of a multiresidue method for measuring fourteen chemical groups of pesticides in water by use of LC-MS-MS.

    Science.gov (United States)

    Carvalho, J J; Jerónimo, P C A; Gonçalves, C; Alpendurada, M F

    2008-11-01

    European Council Directive 98/83/EC on the quality of water intended for human consumption brought a new challenge for water-quality control routine laboratories, mainly on pesticides analysis. Under the guidelines of ISO/IEC 17025:2005, a multiresidue method was developed, validated, implemented in routine, and studied with real samples during a one-year period. The proposed method enables routine laboratories to handle a large number of samples, since 28 pesticides of 14 different chemical groups can be quantitated in a single procedure. The method comprises a solid-phase extraction step and subsequent analysis by liquid chromatography-mass spectrometry (LC-MS-MS). The accuracy was established on the basis of participation in interlaboratory proficiency tests, with encouraging results (majority |z-score| <2), and the precision was consistently analysed over one year. The limits of quantitation (below 0.050 microg L(-1)) are in agreement with the enforced threshold value for pesticides of 0.10 microg L(-1). Overall method performance is suitable for routine use according to accreditation rules, taking into account the data collected over one year.

  7. A novel HPLC-MS/MS method for the simultaneous determination of astemizole and its major metabolite in dog or monkey plasma and application to pharmacokinetics.

    Science.gov (United States)

    Back, Hyun-moon; Lee, Jong-Hwa; Chae, Jung-woo; Song, Byungjeong; Seo, Joung-Wook; Yun, Hwi-yeol; Kwon, Kwang-il

    2015-10-10

    Astemizole (AST), a second-generation antihistamine, is metabolized to desmethyl astemizole (DEA), and although it has been removed from the market for inducing QT interval prolongation, it has reemerged as a potential anticancer and antimalarial agent. This report describes a novel high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method for simultaneously determining the concentrations of AST and DEA in beagle dog and cynomolgus monkey plasma with simple preparation method and short retention time. Prior to HPLC analyses, the plasma samples were extracted with simple liquid-liquid extraction method. The isocratic mobile phase was 0.025% trifluoroacetic acid (TFA dissolved in acetonitrile) and 20 mM ammonium acetate (94:6) at a flow rate of 0.25 mL/min and diphenhydramine used as internal standard. In MS/MS analyses, precursor ions of the analytes were optimized as protonated molecular ions: [M+H](+). The lower limit of quantification of astemizole was 2.5 ng/mL in both species and desmethyl astemizole were 7.5 ng/mL and 10 ng/mL in dog and monkey plasma, respectively. The accuracy, precision, and stability of the method were in accordance with FDA guidelines for the validation of bioanalytical methods. Finally this validated method was successfully applied to a pharmacokinetic study in dogs and monkeys after oral administration of 10 mg/kg AST. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Automated protein identification by the combination of MALDI MS and MS/MS spectra from different instruments.

    Science.gov (United States)

    Levander, Fredrik; James, Peter

    2005-01-01

    The identification of proteins separated on two-dimensional gels is most commonly performed by trypsin digestion and subsequent matrix-assisted laser desorption ionization (MALDI) with time-of-flight (TOF). Recently, atmospheric pressure (AP) MALDI coupled to an ion trap (IT) has emerged as a convenient method to obtain tandem mass spectra (MS/MS) from samples on MALDI target plates. In the present work, we investigated the feasibility of using the two methodologies in line as a standard method for protein identification. In this setup, the high mass accuracy MALDI-TOF spectra are used to calibrate the peptide precursor masses in the lower mass accuracy AP-MALDI-IT MS/MS spectra. Several software tools were developed to automate the analysis process. Two sets of MALDI samples, consisting of 142 and 421 gel spots, respectively, were analyzed in a highly automated manner. In the first set, the protein identification rate increased from 61% for MALDI-TOF only to 85% for MALDI-TOF combined with AP-MALDI-IT. In the second data set the increase in protein identification rate was from 44% to 58%. AP-MALDI-IT MS/MS spectra were in general less effective than the MALDI-TOF spectra for protein identification, but the combination of the two methods clearly enhanced the confidence in protein identification.

  9. UNE-EN ISO/IEC 17025:2005-accredited method for the determination of pesticide residues in fruit and vegetable samples by LC-MS/MS.

    Science.gov (United States)

    Camino-Sánchez, F J; Zafra-Gómez, A; Oliver-Rodríguez, B; Ballesteros, O; Navalón, A; Crovetto, G; Vílchez, J L

    2010-11-01

    A rapid, simple and sensitive multi-residue method was developed and validated for the simultaneous quantification and confirmation of 69 pesticides in fruit and vegetables using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The samples were extracted following the quick, easy, cheap, effective, rugged and safe method known as QuEChERS. Mass spectrometric conditions were individually optimised for each analyte in order to achieve maximum sensitivity in multiple reaction monitoring (MRM) mode. Using the developed chromatographic conditions, 69 pesticides can be separated in less than 17 min. Two selected reaction monitoring (SRM) assays were used for each pesticide to obtain simultaneous quantification and identification in one run. With this method in SRM mode, more than 150 pesticides can be analysed and quantified, but their confirmation is not possible in all cases according to the European regulations on pesticide residues. Nine common representative matrices (zucchini, melon, cucumber, watermelon, tomato, garlic, eggplant, lettuce and pepper) were selected to investigate the effect of different matrices on recovery and precision. Mean recoveries ranged from 70% to 120%, with relative standard deviations (RSDs) lower than 20% for all the pesticides. The proposed method was applied to the analysis of more than 2000 vegetable samples from the extensive greenhouse cultivation in the province of Almeria, Spain, during one year. The methodology combines the advantages of both QuEChERS and LC-MS/MS producing a very rapid, sensitive, accurate and reliable procedure that can be applied in routine analytical laboratories. The method was validated and accredited according to UNE-EN-ISO/IEC 17025:2005 international standard (accreditation number 278/LE1027).

  10. Microstructure and characterization of W-type hexaferrite Ba1-xLaxFe22+Fe163+O27 prepared by solid state method

    Science.gov (United States)

    Tang, Jin; Liu, Xiansong; Mehmood Ur Rehman, Khalid; Li, Dan; Li, Mingling; Yang, Yujie

    2018-04-01

    We report a successful preparation of Ba1-xLaxFe22+Fe163+O27 (x = 0.00-0.10) W-type hexagonal ferrites by standard ceramic method in a reduced oxygen atmosphere. In this work, the effect of the substitution La3+ rare-earth ions for Ba2+ ions on the structural and magnetic properties of the prepared samples have been studied. The phase identification of magnetic powders was performed by X-ray diffraction. The results of XRD show that the single phase was observed in the W-type ferrites with different La content. The SEM micrographs showed that the ferrites have formed the hexagonal structure. The magnetic properties of the samples were metric by a vibrating sample magnetometer. The coercivity (Hc) of the particles decreases with the increase of La content(x), while the saturation magnetization (Ms) of the particles first increases with x from 0 to 0.05, and then begins to decrease when x continues to increase. The monotonic dependence of the magnetic anisotropy field Ha and coercivity Hc on the La3+ doping amount is found to be mainly dominated by the competition between Ms and Keff.

  11. Inductively coupled plasma mass spectrometry (ICP-MS)

    International Nuclear Information System (INIS)

    Shimamura, Tadashi

    1997-01-01

    The period of investigation for the previous general remarks on the progress of ICP-MS was from January, 1991 to September, 1993. In the investigation of this time, for the object of the Chemical Abstracts from January, 1994 to September, 1996, retrieval was carried out by using the STN International. As the key words, ICP-MS, Inductively Coupled Plasma Mass Spectrometry or Inductively Coupled Plasma Mass Spectrometer was used. The number of hit was 373 in 1994, 462 in 1995, and 356 as of September, 1996, 1191 in total. The cumulative number of the papers from 1980 to 1996 is shown. It is known how rapidly the ICP-MS has pervaded as the means of analysis. In order to cope with the enormous number of papers, this time, it was decided to do the review by limiting to the papers which were published in the main journals deeply related to analytical chemistry. As to the tendency in the last three years, it is summarized as how to overcome the spectrum interference and matrix effect in the ICP-MS and the trend of using the ICP-MS as the high sensitivity detector for separation techniques. The technical basic research of the ICP-MS on spectrum interference, sample introduction method and others and the analysis of living body samples are reported. (K.I.)

  12. Development of a Multi-class Steroid Hormone Screening Method using Liquid Chromatography/Tandem Mass Spectrometry (LC-MS/MS)

    Science.gov (United States)

    Boggs, Ashley S. P.; Bowden, John A.; Galligan, Thomas M.; Guillette, Louis J.; Kucklick, John R.

    2016-01-01

    Monitoring complex endocrine pathways is often limited by indirect measurement or measurement of a single hormone class per analysis. There is a burgeoning need to develop specific direct-detection methods capable of providing simultaneous measurement of biologically relevant concentrations of multiple classes of hormones (estrogens, androgens, progestogens, and corticosteroids). The objectives of this study were to develop a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for multi-class steroid hormone detection using biologically relevant concentrations, then test limits of detection (LOD) in a high-background matrix by spiking charcoal-stripped fetal bovine serum (FBS) extract. Accuracy was tested with National Institute of Standards and Technology Standard Reference Materials (SRMs) with certified concentrations of cortisol, testosterone, and progesterone. 11-Deoxycorticosterone, 11-deoxycortisol, 17-hydroxypregnenolone, 17-hydroxyprogesterone, adrenosterone, androstenedione, cortisol, corticosterone, dehydroepiandrosterone, dihydrotestosterone, estradiol, estriol, estrone, equilin, pregnenolone, progesterone, and testosterone were also measured using isotopic dilution. Dansyl chloride (DC) derivatization was investigated maintaining the same method to improve and expedite estrogen analysis. Biologically relevant LODs were determined for 15 hormones. DC derivatization improved estrogen response two- to eight-fold, and improved chromatographic separation. All measurements had an accuracy ≤ 14 % difference from certified values (not accounting for uncertainty) and relative standard deviation ≤ 14 %. This method chromatographically separated and quantified biologically relevant concentrations of four hormone classes using highly specific fragmentation patterns and measured certified values of hormones that were previously split into three separate chromatographic methods. PMID:27039201

  13. Dansyl-peptides matrix-assisted laser desorption/ionization mass spectrometric (MALDI-MS) and tandem mass spectrometric (MS/MS) features improve the liquid chromatography/MALDI-MS/MS analysis of the proteome.

    Science.gov (United States)

    Chiappetta, Giovanni; Ndiaye, Sega; Demey, Emmanuelle; Haddad, Iman; Marino, Gennaro; Amoresano, Angela; Vinh, Joëlle

    2010-10-30

    Peptide tagging is a useful tool to improve matrix-assisted laser desorption/ionization tandem mass spectrometric (MALDI-MS/MS) analysis. We present a new application of the use of the dansyl chloride (DNS-Cl). DNS-Cl is a specific primary amine reagent widely used in protein biochemistry. It adds a fluorescent dimethylaminonaphthalene moiety to the molecule. The evaluation of MALDI-MS and MS/MS analyses of dansylated peptides shows that dansylation raises the ionization efficiency of the most hydrophilic species compared with the most hydrophobic ones. Consequently, higher Mascot scores and protein sequence coverage are obtained by combining MS and MS/MS data of native and tagged samples. The N-terminal DNS-Cl sulfonation improves the peptide fragmentation and promotes the generation of b-fragments allowing better peptide sequencing. In addition, we set up a labeling protocol based on the microwave chemistry. Peptide dansylation proved to be a rapid and cheap method to improve the performance of liquid chromatography (LC)/MALDI-MS/MS analysis at the proteomic scale in terms of peptide detection and sequence coverage. Copyright © 2010 John Wiley & Sons, Ltd.

  14. Rapid and Sensitive Determination of Timosaponin AIII in Rat Plasma by LC-MS/MS and Its Pharmacokinetic Application

    Directory of Open Access Journals (Sweden)

    Zhenzhen Cai

    2013-02-01

    Full Text Available A rapid sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS method was developed for determination of timosaponin AIII (TA-III in rat plasma, using ginsenoside Re as an internal standard (IS. TA-III and the IS were detected in MRM mode with a negative ionization electrospray mass spectrometer. The calibration curves were linear over the concentration ranges from 11.14 to 1114 ng/mL and the lower limit of quantification (LLOQ was 11.14 ng/mL. Intra-day and inter-day precisions (RSD were within 10%, and accuracy ranged from 6.4% to 9.1%. The extraction recovery at three concentrations ranged from 92.3% to 95.5%. The validated method was successfully applied to monitor the concentrations of TA-III in rat plasma after intragastric administration. The best fit pharmacokinetic model to estimate the pharmacokinetic parameters was a single compartment model with weight of 1/x2 for oral administration groups of rats for TA-III.

  15. Analysis of pesticide residues in strawberries and soils by GC-MS/MS, LC-MS/MS and two-dimensional GC-time-of-flight MS comparing organic and integrated pest management farming.

    Science.gov (United States)

    Fernandes, Virgínia C; Lehotay, Steven J; Geis-Asteggiante, Lucía; Kwon, Hyeyoung; Mol, Hans G J; van der Kamp, Henk; Mateus, Nuno; Domingues, Valentina F; Delerue-Matos, Cristina

    2014-01-01

    This study analysed 22 strawberry and soil samples after their collection over the course of 2 years to compare the residue profiles from organic farming with integrated pest management practices in Portugal. For sample preparation, we used the citrate-buffered version of the quick, easy, cheap, effective, rugged, and safe (QuEChERS) method. We applied three different methods for analysis: (1) 27 pesticides were targeted using LC-MS/MS; (2) 143 were targeted using low pressure GC-tandem mass spectrometry (LP-GC-MS/MS); and (3) more than 600 pesticides were screened in a targeted and untargeted approach using comprehensive, two-dimensional gas chromatography time-of-flight mass spectrometry (GC × GC-TOF-MS). Comparison was made of the analyses using the different methods for the shared samples. The results were similar, thereby providing satisfactory confirmation of both similarly positive and negative findings. No pesticides were found in the organic-farmed samples. In samples from integrated pest management practices, nine pesticides were determined and confirmed to be present, ranging from 2 µg kg(-1) for fluazifop-p-butyl to 50 µg kg(-1) for fenpropathrin. Concentrations of residues in strawberries were less than European maximum residue limits.

  16. The validation & verification of an LC/MS method for the determination of total docosahexaenoic acid concentrations in canine blood serum.

    Science.gov (United States)

    Dillon, Gerald Patrick; Keegan, Jason D; Wallace, Geoff; Yiannikouris, Alexandros; Moran, Colm Anthony

    2018-06-01

    Docosahexaenoic acid (DHA), is an omega 3 fatty acid (n-3 FA) that has been shown to play a role in canine growth and physiological integrity and improvements in skin and coat condition. However, potential adverse effects of n-3 FA specifically, impaired cellular immunity has been observed in dogs fed diets with elevated levels of n-3 FA. As such, a safe upper limit (SUL) for total n-3 FAs (DHA and EPA) in dogs has been established. Considering this SUL, sensitive methods detecting DHA in blood serum as a biomarker when conducting n-3 FA supplementation trials involving dogs are required. In this study, an LC-ESI-MS/MS method of DHA detection in dog serum was validated and verified. Recovery of DHA was optimized and parallelism tests were conducted with spiked samples demonstrating that the serum matrix did not interfere with quantitation. The stability of DHA in serum was also investigated, with -80 °C considered suitable when storing samples for up to six months. The method was linear over a calibration range of 1-500 μg/mL and precision and accuracy were found to meet the requirements for validation. This method was verified in an alternative laboratory using a different analytical system and operator, with the results meeting the criteria for verification. Copyright © 2018. Published by Elsevier Inc.

  17. LC/MS Method for the Determination of Stable Isotope Labeled Promethazine in Human Plasma

    Science.gov (United States)

    Zuwei, Wang; Boyd, Jason; Berens, Kurt L.; Putcha, Lakshmi

    2004-01-01

    Promethazine (PMZ) is taken by astronauts orally (PO), intramuscularly (IM) or rectally (PR) for space motion sickness. LC/MS method was developed with off-line solid phase extraction to measure plasma concentrations of PMZ given as stable isotope-labeled (SIL) formulations by the three different routes of administration simultaneously. Samples (0.5ml) were loaded on to Waters Oasis HLB co-polymer cartridges and eluted with 1.0 mL methanol. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 6 min. Acetonitrile/ ammonium acetate (30 mM) in water (3:2, v/v), pH 5.6 plus or minus 0.1, was used as the mobile phase for separation. Concentrations of PMZ, PMZ-d4 and PMZ-d7 and chlorpromazine (internal standard) were determined using a Micromass ZMD single quadrupole mass spectrometer with Electrospray Ionization (ESI). ESI mass spectra were acquired in positive ion mode with selected ion monitoring of [M+ H]dot plus. The method is rapid, reproducible and the assay specific parameters are listed in a table. A novel, sensitive and specific method for the measurement of PMZ and SIL PMZ in human plasma is reported.

  18. UHPLC/MS-MS Analysis of Six Neonicotinoids in Honey by Modified QuEChERS: Method Development, Validation, and Uncertainty Measurement

    Directory of Open Access Journals (Sweden)

    Michele Proietto Galeano

    2013-01-01

    Full Text Available Rapid and reliable multiresidue analytical methods were developed and validated for the determination of 6 neonicotinoids pesticides (acetamiprid, clothianidin, imidacloprid, nitenpyram, thiacloprid, and thiamethoxam in honey. A modified QuEChERS method has allowed a very rapid and efficient single-step extraction, while the detection was performed by UHPLC/MS-MS. The recovery studies were carried out by spiking the samples at two concentration levels (10 and 40 μg/kg. The methods were subjected to a thorough validation procedure. The mean recovery was in the range of 75 to 114% with repeatability below 20%. The limits of detection were below 2.5 μg/kg, while the limits of quantification did not exceed 4.0 μg/kg. The total uncertainty was evaluated taking the main independent uncertainty sources under consideration. The expanded uncertainty did not exceed 49% for the 10 μg/kg concentration level and was in the range of 16–19% for the 40 μg/kg fortification level.

  19. Analytical Method Details (MS): SE57_MS01 [Metabolonote[Archive

    Lifescience Database Archive (English)

    Full Text Available TQD, UPLC (Waters) UPLC-QTOF-MS ESI N.A. All the solutions of authentic....1% formic acid), with a 2.5 min cycle in the isocratic mode. The ionized authentic compounds were detected ... optimal CV and CE were determined automatically for 497 of these compounds using the software QuanOptimize

  20. Development of Mycoplasma synoviae (MS) core genome multilocus sequence typing (cgMLST) scheme.

    Science.gov (United States)

    Ghanem, Mostafa; El-Gazzar, Mohamed

    2018-05-01

    Mycoplasma synoviae (MS) is a poultry pathogen with reported increased prevalence and virulence in recent years. MS strain identification is essential for prevention, control efforts and epidemiological outbreak investigations. Multiple multilocus based sequence typing schemes have been developed for MS, yet the resolution of these schemes could be limited for outbreak investigation. The cost of whole genome sequencing became close to that of sequencing the seven MLST targets; however, there is no standardized method for typing MS strains based on whole genome sequences. In this paper, we propose a core genome multilocus sequence typing (cgMLST) scheme as a standardized and reproducible method for typing MS based whole genome sequences. A diverse set of 25 MS whole genome sequences were used to identify 302 core genome genes as cgMLST targets (35.5% of MS genome) and 44 whole genome sequences of MS isolates from six countries in four continents were used for typing applying this scheme. cgMLST based phylogenetic trees displayed a high degree of agreement with core genome SNP based analysis and available epidemiological information. cgMLST allowed evaluation of two conventional MLST schemes of MS. The high discriminatory power of cgMLST allowed differentiation between samples of the same conventional MLST type. cgMLST represents a standardized, accurate, highly discriminatory, and reproducible method for differentiation between MS isolates. Like conventional MLST, it provides stable and expandable nomenclature, allowing for comparing and sharing the typing results between different laboratories worldwide. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  1. Simultaneous determination of telmisartan and amlodipine in dog plasma by LC-MS-MS.

    Science.gov (United States)

    Wang, Baolian; Sheng, Li; Li, Yan

    2015-01-01

    A simple, rapid and sensitive method was established for the simultaneous determination of telmisartan and amlodipine in dog plasma by a HPLC-MS-MS analysis. The plasma sample preparation was a simple deproteinization by the addition of three volumes of methanol/acetonitrile mixture followed by centrifugation. The analytes and internal standard diphenhydramine were separated on a Zorbax SB-C18 column with a mobile phase of acetonitrile : water (45 : 55, v/v) at a flow rate of 0.2 mL/min with an operating temperature of 25°C. Detection was carried out by electrospray ionization in positive-ion multiple reaction monitoring mode. The calibration plots in dog plasma were linear over the ranges of 0.5-2,000 ng/mL for telmisartan and 0.5-500 ng/mL for amlodipine. The lower limit of quantification was 0.5 ng/mL for two analytes. The intra- and interday precisions (RSD%) were within 9.0%. The average recoveries of analytes were >85.0%. The method was successfully applied to the pharmacokinetic study of the two compounds after oral administration of telmisartan-amlodipine combination preparation to dogs. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Development of a LC-MS/MS Method for the Multi-Mycotoxin Determination in Composite Cereal-Based Samples

    Directory of Open Access Journals (Sweden)

    Barbara De Santis

    2017-05-01

    Full Text Available The analytical scenario for determining contaminants in the food and feed sector is constantly prompted by the progress and improvement of knowledge and expertise of researchers and by the technical innovation of the instrumentation available. Mycotoxins are agricultural contaminants of fungal origin occurring at all latitudes worldwide and being characterized by acute and chronic effects on human health and animal wellness, depending on the species sensitivity. The major mycotoxins of food concern are aflatoxin B1 and ochratoxin A, the first for its toxicity, and the second for its recurrent occurrence. However, the European legislation sets maximum limits for mycotoxins, such as aflatoxin B1, ochratoxin A, deoxynivalenol, fumonisins, and zearalenone, and indicative limits for T-2 and HT-2 toxins. Due to the actual probability that co-occurring mycotoxins are present in a food or feed product, nowadays, the availability of reliable, sensitive, and versatile multi-mycotoxin methods is assuming a relevant importance. Due to the wide range of matrices susceptible to mycotoxin contamination and the possible co-occurrence, a multi-mycotoxin and multi-matrix method was validated in liquid chromatography-tandem mass spectrometry (LC-MS/MS with the purpose to overcome specific matrix effects and analyze complex cereal-based samples within the Italian Total Diet Study project.

  3. A rapid and sensitive method for the simultaneous analysis of aliphatic and polar molecules containing free carboxyl groups in plant extracts by LC-MS/MS

    Directory of Open Access Journals (Sweden)

    Bonaventure Gustavo

    2009-11-01

    Full Text Available Abstract Background Aliphatic molecules containing free carboxyl groups are important intermediates in many metabolic and signalling reactions, however, they accumulate to low levels in tissues and are not efficiently ionized by electrospray ionization (ESI compared to more polar substances. Quantification of aliphatic molecules becomes therefore difficult when small amounts of tissue are available for analysis. Traditional methods for analysis of these molecules require purification or enrichment steps, which are onerous when multiple samples need to be analyzed. In contrast to aliphatic molecules, more polar substances containing free carboxyl groups such as some phytohormones are efficiently ionized by ESI and suitable for analysis by LC-MS/MS. Thus, the development of a method with which aliphatic and polar molecules -which their unmodified forms differ dramatically in their efficiencies of ionization by ESI- can be simultaneously detected with similar sensitivities would substantially simplify the analysis of complex biological matrices. Results A simple, rapid, specific and sensitive method for the simultaneous detection and quantification of free aliphatic molecules (e.g., free fatty acids (FFA and small polar molecules (e.g., jasmonic acid (JA, salicylic acid (SA containing free carboxyl groups by direct derivatization of leaf extracts with Picolinyl reagent followed by LC-MS/MS analysis is presented. The presence of the N atom in the esterified pyridine moiety allowed the efficient ionization of 25 compounds tested irrespective of their chemical structure. The method was validated by comparing the results obtained after analysis of Nicotiana attenuata leaf material with previously described analytical methods. Conclusion The method presented was used to detect 16 compounds in leaf extracts of N. attenuata plants. Importantly, the method can be adapted based on the specific analytes of interest with the only consideration that the

  4. Evaluation of a fast and simple sample preparation method for PBDE flame retardants and DDT pesticides in fish for analysis by ELISA compared with GC-MS/MS

    Science.gov (United States)

    A simple, fast, and cost-effective sample preparation method, previously developed and validated for the analysis of organic contaminants in fish using low-pressure gas chromatography tandem mass spectrometry (LPGC-MS/MS), was evaluated for analysis of polybrominated diphenyl ethers (PBDEs) and dich...

  5. Ion-pair chromatography coupled to inductively coupled plasma-mass spectrometry (IPC-ICP-MS) as a method for thiomolybdate speciation in natural waters.

    Science.gov (United States)

    Lohmayer, Regina; Reithmaier, Gloria Maria Susanne; Bura-Nakić, Elvira; Planer-Friedrich, Britta

    2015-03-17

    Molybdenum precipitates preferentially under reducing conditions; therefore, its occurrence in sediment records is used as an indicator of paleoredox conditions. Although thiomolybdates (MoO4-xSx(2-) with x = 1-4) supposedly are necessary intermediates in the process of molybdenum precipitation under anoxic conditions, there is no information about their abundance in natural environments, because of a lack of element-specific methods with sufficiently low detection limits. Here, we optimized ion-pair chromatographic separation for coupling to an inductively coupled plasma-mass spectrometry detector (IPC-ICP-MS). 2-Propanol (10%-25% gradient) replaced the previously used acetonitrile (25%-75%) as the solvent, to reduce the carbon load into the plasma. In synthetic solutions, formation of thiomolybdates was found to occur spontaneously in the presence of excess sulfide and the degree of thiolation was highest at pH 7. Excess hydroxyl led to a transformation of thiomolybdates to molybdate. Under acidic to neutral conditions, precipitation of molybdenum and hydrolysis of tetrathiomolybdate were observed. Flash-freezing was found to be suitable to stabilize tetrathiomolybdate, with 2 mM) negatively affected the detection of molybdate, which eluted mainly in the dead volume, but had no negative effect on higher thiolated molybdates. Detection limits were ∼10 nM. With the newly developed IPC-ICP-MS method, thiomolybdates were found to form spontaneously in euxinic marine waters after adding a molybdate spike and occur naturally in sulfidic geothermal waters.

  6. Quantitative Determination of Perfluorochemicals and Fluorotelomer Alcohols in Plants from Biosolid-Amended Fields using LC/MS/MS and GC/MS

    Science.gov (United States)

    Analytical methods for determining perfluorochemicals (PFCs) and fluorotelomer alcohols (FTOHs) in plants using liquid chromatography/tandem mass spectrometry (LC/MS/MS) and gas chromatography/mass spectrometry (GC/MS) were developed, and applied to quantify a suite of analytes i...

  7. A simple validated multi-analyte method for detecting drugs in oral fluid by ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS).

    Science.gov (United States)

    Zheng, Yufang; Sparve, Erik; Bergström, Mats

    2018-06-01

    A UPLC-MS/MS method was developed to identify and quantitate 37 commonly abused drugs in oral fluid. Drugs of interest included amphetamines, benzodiazepines, cocaine, opiates, opioids, phencyclidine and tetrahydrocannabinol. Sample preparation and extraction are simple, and analysis times short. Validation showed satisfactory performance at relevant concentrations. The possibility of contaminated samples as well as the interpretation in relation to well-knows matrices, such as urine, will demand further study. Copyright © 2017 John Wiley & Sons, Ltd.

  8. MID Max: LC–MS/MS Method for Measuring the Precursor and Product Mass Isotopomer Distributions of Metabolic Intermediates and Cofactors for Metabolic Flux Analysis Applications

    DEFF Research Database (Denmark)

    McCloskey, Douglas; Young, Jamey D.; Xu, Sibei

    2016-01-01

    The analytical challenges to acquire accurate isotopic data of intracellular metabolic intermediates for stationary, nonstationary, and dynamic metabolic flux analysis (MFA) are numerous. This work presents MID Max, a novel LC–MS/MS workflow, acquisition, and isotopomer deconvolution method for MFA...... that takes advantage of additional scan types that maximizes the number of mass isotopomer distributions (MIDs) that can be acquired in a given experiment. The analytical method was found to measure the MIDs of 97 metabolites, corresponding to 74 unique metabolite-fragment pairs (32 precursor spectra and 42...

  9. Quality evaluation of LC-MS/MS-based E. coli H antigen typing (MS-H) through label-free quantitative data analysis in a clinical sample setup.

    Science.gov (United States)

    Cheng, Keding; Sloan, Angela; McCorrister, Stuart; Peterson, Lorea; Chui, Huixia; Drebot, Mike; Nadon, Celine; Knox, J David; Wang, Gehua

    2014-12-01

    The need for rapid and accurate H typing is evident during Escherichia coli outbreak situations. This study explores the transition of MS-H, a method originally developed for rapid H antigen typing of E. coli using LC-MS/MS of flagella digest of reference strains and some clinical strains, to E. coli isolates in clinical scenario through quantitative analysis and method validation. Motile and nonmotile strains were examined in batches to simulate clinical sample scenario. Various LC-MS/MS batch run procedures and MS-H typing rules were compared and summarized through quantitative analysis of MS-H data output for a standard method development. Label-free quantitative data analysis of MS-H typing was proven very useful for examining the quality of MS-H result and the effects of some sample carryovers from motile E. coli isolates. Based on this, a refined procedure and protein identification rule specific for clinical MS-H typing was established and validated. With LC-MS/MS batch run procedure and database search parameter unique for E. coli MS-H typing, the standard procedure maintained high accuracy and specificity in clinical situations, and its potential to be used in a clinical setting was clearly established. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. A General Method for Targeted Quantitative Cross-Linking Mass Spectrometry.

    Directory of Open Access Journals (Sweden)

    Juan D Chavez

    Full Text Available Chemical cross-linking mass spectrometry (XL-MS provides protein structural information by identifying covalently linked proximal amino acid residues on protein surfaces. The information gained by this technique is complementary to other structural biology methods such as x-ray crystallography, NMR and cryo-electron microscopy[1]. The extension of traditional quantitative proteomics methods with chemical cross-linking can provide information on the structural dynamics of protein structures and protein complexes. The identification and quantitation of cross-linked peptides remains challenging for the general community, requiring specialized expertise ultimately limiting more widespread adoption of the technique. We describe a general method for targeted quantitative mass spectrometric analysis of cross-linked peptide pairs. We report the adaptation of the widely used, open source software package Skyline, for the analysis of quantitative XL-MS data as a means for data analysis and sharing of methods. We demonstrate the utility and robustness of the method with a cross-laboratory study and present data that is supported by and validates previously published data on quantified cross-linked peptide pairs. This advance provides an easy to use resource so that any lab with access to a LC-MS system capable of performing targeted quantitative analysis can quickly and accurately measure dynamic changes in protein structure and protein interactions.

  11. Development and validation of an LC-MS/MS method for the determination of biogenic amines in wines and beers.

    Science.gov (United States)

    Nalazek-Rudnicka, Katarzyna; Wasik, Andrzej

    2017-01-01

    Biogenic amines are group of organic, basic, nitrogenous compounds that naturally occur in plant, microorganism, and animal organisms. Biogenic amines are mainly produced through decarboxylation of amino acids. They are formed during manufacturing of some kind of food and beverages such as cheese, wine, or beer. Histamine, cadaverine, agmatine, tyramine, putrescine, and β -phenylethylamine are the most common biogenic amines found in wines and beers. This group of compounds can be toxic at high concentrations; therefore, their control is very important. Analysis of biogenic amines in alcoholic drinks (beers and wines) was carried out by HPLC-MS/MS after their derivatization with p -toluenesulfonyl chloride (tosyl chloride). The developed method has been applied for analysis of seventeen biogenic amines in twenty-eight samples of lager beers and in twelve samples of different homemade wines (white grape, red grape, strawberry, chokeberry, black currant, plum, apple, raspberry, and quince). The developed method is sensitive and repeatable for majority of the analytes. It is versatile and can be used for the determination of biogenic amines in various alcoholic beverages.

  12. LFQuant: a label-free fast quantitative analysis tool for high-resolution LC-MS/MS proteomics data.

    Science.gov (United States)

    Zhang, Wei; Zhang, Jiyang; Xu, Changming; Li, Ning; Liu, Hui; Ma, Jie; Zhu, Yunping; Xie, Hongwei

    2012-12-01

    Database searching based methods for label-free quantification aim to reconstruct the peptide extracted ion chromatogram based on the identification information, which can limit the search space and thus make the data processing much faster. The random effect of the MS/MS sampling can be remedied by cross-assignment among different runs. Here, we present a new label-free fast quantitative analysis tool, LFQuant, for high-resolution LC-MS/MS proteomics data based on database searching. It is designed to accept raw data in two common formats (mzXML and Thermo RAW), and database search results from mainstream tools (MASCOT, SEQUEST, and X!Tandem), as input data. LFQuant can handle large-scale label-free data with fractionation such as SDS-PAGE and 2D LC. It is easy to use and provides handy user interfaces for data loading, parameter setting, quantitative analysis, and quantitative data visualization. LFQuant was compared with two common quantification software packages, MaxQuant and IDEAL-Q, on the replication data set and the UPS1 standard data set. The results show that LFQuant performs better than them in terms of both precision and accuracy, and consumes significantly less processing time. LFQuant is freely available under the GNU General Public License v3.0 at http://sourceforge.net/projects/lfquant/. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. About this Publishing System

    African Journals Online (AJOL)

    This journal uses Open Journal Systems 2.4.3.0, which is open source journal management and publishing software developed, supported, and freely distributed by the Public Knowledge Project under the GNU General Public License. OJS Editorial and Publishing Process. ISSN: 0258-252X. AJOL African Journals Online.

  14. About this Publishing System

    African Journals Online (AJOL)

    This journal uses Open Journal Systems 2.4.3.0, which is open source journal management and publishing software developed, supported, and freely distributed by the Public Knowledge Project under the GNU General Public License. OJS Editorial and Publishing Process. ISSN: 0047-651X. AJOL African Journals Online.

  15. About this Publishing System

    African Journals Online (AJOL)

    This journal uses Open Journal Systems 2.4.3.0, which is open source journal management and publishing software developed, supported, and freely distributed by the Public Knowledge Project under the GNU General Public License. OJS Editorial and Publishing Process. ISSN: 2360-994X. AJOL African Journals Online.

  16. About this Publishing System

    African Journals Online (AJOL)

    This journal uses Open Journal Systems 2.4.3.0, which is open source journal management and publishing software developed, supported, and freely distributed by the Public Knowledge Project under the GNU General Public License. OJS Editorial and Publishing Process. ISSN: 1858-554X. AJOL African Journals Online.

  17. About this Publishing System

    African Journals Online (AJOL)

    This journal uses Open Journal Systems 2.4.3.0, which is open source journal management and publishing software developed, supported, and freely distributed by the Public Knowledge Project under the GNU General Public License. OJS Editorial and Publishing Process. ISSN: 2078-676X. AJOL African Journals Online.

  18. About this Publishing System

    African Journals Online (AJOL)

    This journal uses Open Journal Systems 2.4.3.0, which is open source journal management and publishing software developed, supported, and freely distributed by the Public Knowledge Project under the GNU General Public License. OJS Editorial and Publishing Process. ISSN: 1814-232X. AJOL African Journals Online.

  19. About this Publishing System

    African Journals Online (AJOL)

    This journal uses Open Journal Systems 2.4.3.0, which is open source journal management and publishing software developed, supported, and freely distributed by the Public Knowledge Project under the GNU General Public License. OJS Editorial and Publishing Process. ISSN: 0303-691X. AJOL African Journals Online.

  20. About this Publishing System

    African Journals Online (AJOL)

    This journal uses Open Journal Systems 2.4.3.0, which is open source journal management and publishing software developed, supported, and freely distributed by the Public Knowledge Project under the GNU General Public License. OJS Editorial and Publishing Process. ISSN: 2449-108X. AJOL African Journals Online.

  1. About this Publishing System

    African Journals Online (AJOL)

    This journal uses Open Journal Systems 2.4.3.0, which is open source journal management and publishing software developed, supported, and freely distributed by the Public Knowledge Project under the GNU General Public License. OJS Editorial and Publishing Process. ISSN: 0012-835X. AJOL African Journals Online.

  2. An LC-MS method for determination of milbemycin oxime in dog plasma.

    Science.gov (United States)

    Xu, Qianqian; Li, Jichang; Shen, Zhiqiang; Guo, Shijin; Wang, Yubo; Li, Feng

    2014-10-01

    An HPLC-MS method has been developed and validated for the quantitative determination of milbemycin oxime (MBO) in dog plasma. The developed method has been then applied in in vivo clinical studies to obtain pharmacokinetics of MBO in blood after its oral administration. Samples were extracted using solid-phase extraction (SPE). Sample proteins were precipitated with acetonitrile (ACN) and sodium chloride (NaCl) and then diluted with methanol and water. Calibration standards were prepared by using plasma matrix and following the same SPE procedure. Chromatographic separation was performed on a Waters C18 packed column (3.5 μm particles diameter; 3 × 100 mm) with a C18 guard column (3.5 μm particles diameter; 3 × 20 mm). The mobile phase was an 85:15 (v/v) mixed solution of ACN and 5 mM ammonium acetate. The calibration curve was linear over a concentration range of 2.0-500 ng/mL with a limit of quantitation of 2.0 ng/mL. The oral administration of a pellet of 2.5 mg MBO produced blood concentrations ranging from 6.10 ± 0.92 to 78.81 ± 4.38 ng/mL within 6 h, with a terminal half-time of 11.66 ± 0.93 h. This study determined the suitability of the herein proposed method to investigate the pharmacokinetics of MBO after oral administration. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Evaluation of the QuEChERS method for the extraction of pharmaceuticals and personal care products from drinking-water treatment sludge with determination by UPLC-ESI-MS/MS.

    Science.gov (United States)

    Cerqueira, Maristela B R; Guilherme, Juliana R; Caldas, Sergiane S; Martins, Manoel L; Zanella, Renato; Primel, Ednei G

    2014-07-01

    A modified version of the QuEChERS method has been evaluated for the determination of 21 pharmaceuticals and 6 personal care products (PPCPs) in drinking-water sludge samples by employing ultra high liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The performance of the method was evaluated through linearity, recovery, precision (intra-day), method detection and quantification limits (MDL and MQL) and matrix effect. The calibration curves prepared in acetonitrile and in the matrix extract showed a correlation coefficient ranging from 0.98 to 0.99. MQLs values were on the ng g(-1) order of magnitude for most compounds. Recoveries between 50% and 93% were reached with RSDs lower than 10% for most compounds. Matrix effect was almost absent with values lower than 16% for 93% of the compounds. By coupling a quick and simple extraction called QuEChERS with the UPLC-MS/MS analysis, a method that is both selective and sensitive was obtained. This methodology was successfully applied to real samples and caffeine and benzophenone-3 were detected in ng g(-1) levels. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Rapid HPLC-MS method for the simultaneous determination of tea catechins and folates.

    Science.gov (United States)

    Araya-Farias, Monica; Gaudreau, Alain; Rozoy, Elodie; Bazinet, Laurent

    2014-05-14

    An effective and rapid HPLC-MS method for the simultaneous separation of the eight most abundant tea catechins, gallic acid, and caffeine was developed. These compounds were rapidly separated within 9 min by a linear gradient elution using a Zorbax SB-C18 packed with sub 2 μm particles. This methodology did not require preparative and semipreparative HPLC steps. In fact, diluted tea samples can be easily analyzed using HPLC-MS as described in this study. The use of mass spectrometry detection for quantification of catechins ensured a higher specificity of the method. The percent relative standard deviation was generally lower than 4 and 7% for most of the compounds tested in tea drinks and tea extracts, respectively. Furthermore, the method provided excellent resolution for folate determination alone or in combination with catechins. To date, no HPLC method able to discriminate catechins and folates in a quick analysis has been reported in the literature.

  5. Simultaneous analysis of 17 diuretics in dietary supplements by HPLC and LC-MS/MS.

    Science.gov (United States)

    Woo, H; Kim, J W; Han, K M; Lee, J H; Hwang, I S; Lee, J H; Kim, J; Kweon, S J; Cho, S; Chae, K R; Han, S Y; Kim, J

    2013-01-01

    In order to test health foods for illegally added diuretics for weight loss, we developed simple, rapid, selective, and sensitive methods using HPLC and LC-MS/MS for the simultaneous analysis of 17 diuretics in dietary supplements. HPLC conditions were set with a Capcell-pak C18, using a mobile phase consisting of gradient conditions, UV detection at 254 nm and validated for linearity (r(2)> 0.999), precision (CV ≤ 3%), recoveries (90.4-102.8%) and reproducibility. Identification and quantification of 17 diuretics were accomplished by ion-spray LC-MS/MS using multiple reaction monitoring (MRM). The chromatographic separation was carried out under the reversed-phase mechanism on an HSS-T3 column. The LC-MS/MS method was validated for linearity (r(2)> 0.99) and precision (CV Diuretics were not detected in all samples. Extraction recovery was also investigated and the extraction recoveries in different formulations were from 88% to 110% and from 81% to 116% using HPLC and LC-MS/MS, respectively. There was no significant difference in recoveries in the type of dietary supplements. Based on this result, the developed methods to monitor illegal drug adulterations in dietary supplements using HPLC and LC-MS/MS are simple, fast and reliable. Therefore, it is applicable to routine drug-adulteration screening.

  6. Simplifying sample pretreatment: application of dried blood spot (DBS) method to blood samples, including postmortem, for UHPLC-MS/MS analysis of drugs of abuse.

    Science.gov (United States)

    Odoardi, Sara; Anzillotti, Luca; Strano-Rossi, Sabina

    2014-10-01

    The complexity of biological matrices, such as blood, requires the development of suitably selective and reliable sample pretreatment procedures prior to their instrumental analysis. A method has been developed for the analysis of drugs of abuse and their metabolites from different chemical classes (opiates, methadone, fentanyl and analogues, cocaine, amphetamines and amphetamine-like substances, ketamine, LSD) in human blood using dried blood spot (DBS) and subsequent UHPLC-MS/MS analysis. DBS extraction required only 100μL of sample, added with the internal standards and then three droplets (30μL each) of this solution were spotted on the card, let dry for 1h, punched and extracted with methanol with 0.1% of formic acid. The supernatant was evaporated and the residue was then reconstituted in 100μL of water with 0.1% of formic acid and injected in the UHPLC-MS/MS system. The method was validated considering the following parameters: LOD and LOQ, linearity, precision, accuracy, matrix effect and dilution integrity. LODs were 0.05-1ng/mL and LOQs were 0.2-2ng/mL. The method showed satisfactory linearity for all substances, with determination coefficients always higher than 0.99. Intra and inter day precision, accuracy, matrix effect and dilution integrity were acceptable for all the studied substances. The addition of internal standards before DBS extraction and the deposition of a fixed volume of blood on the filter cards ensured the accurate quantification of the analytes. The validated method was then applied to authentic postmortem blood samples. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  7. Determination of Scopolamine in Human Saliva Using Solid Phase Extraction and LC/MS/MS

    Science.gov (United States)

    Wang, Zuwei; Vaksman, Zalman; Boyd, Jason; Putcha, Lakshmi

    2007-01-01

    Purpose: Scopolamine is the preferred treatment for motion sickness during space flight because of its quick onset of action, short half-life and favorable side-effect profile. The dose administered depends on the mode of administration and usually ranges between 0.1 and 0.8 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids by using conventional HPLC methods. To measure scopolamine in saliva and thereby to evaluate the pharmacokinetics of scopolamine, we developed an LC/MS/MS method using off-line solid phase extraction. Method: Samples (0.5mL) were loaded onto Waters Oasis HLB co-polymer cartridges (10 mg, 1 mL) and eluted with 0.5 mL methanol without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 4 minutes. The mobile phase for separation was 90:10 (v/v) methanol: ammonium acetate (2 mM) in water, pH 5.0 +/- 0.1. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 yields 138.1 and internal standard (IS) hyoscyamine m/z = 290.2 yields 124.1. Results: The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at 1.7 and 3.2 min respectively. The linear range is 50-5000 pg/mL for scopolamine in saliva with correlation coefficients > 0.99 with a CV < 0.5 %. The intra-day and inter-day CVs are < 15 % for quality control samples with concentrations of 75, 300, 750 and 3000 pg/mL of scopolamine in human saliva. Conclusion: Solid phase extraction allows more rapid sample preparation and greater precision than liquid extraction. Furthermore, we increased the sensitivity and specificity by adjusting the LC mobile phase and using an MS/MS

  8. Determination method for 129I in soil samples by MIP-MS

    International Nuclear Information System (INIS)

    Uezu, Yasuhiro; Nakano, Masanao; Fujita, Hiroki; Watanabe, Hitoshi; Maruo, Yoshihiro

    2001-01-01

    The radioactive iodine-129 ( 129 I) is an important radionuclide for environmental assessment because it has a long half-life and is accumulated in the thyroid gland in humans. A new analytical technique by Microwave Induced Plasma Mass Spectrometer (MIP-MS) was applied to the determination of 129 I in soil samples. In environmental samples, a large amount of matrix elements are present. Therefore, the matrix elements were eliminated by ashing at 1000degC, and iodine isotopes were trapped by an activated charcoal and finally extracted by 10% tetramethylammonium hydroxide (TMAH). The concentration of 129 I in a soil samples were compared between results of neutron activation analysis and MIP-MS method. The results showed an excellent agreement. (author)

  9. A validated multianalyte LC-MS/MS method for quantification of 25 mycotoxins in cassava flour, peanut cake and maize samples.

    Science.gov (United States)

    Ediage, Emmanuel Njumbe; Di Mavungu, José Diana; Monbaliu, Sofie; Van Peteghem, Carlos; De Saeger, Sarah

    2011-05-25

    This study was designed to develop a sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the simultaneous detection and quantification of 25 mycotoxins in cassava flour, peanut cake and maize samples with particular focus on the optimization of the sample preparation protocol and method validation. All 25 mycotoxins were extracted in a single step with a mixture of methanol/ethyl acetate/water (70:20:10, v/v/v). The method limits of quantification (LOQ) varied from 0.3 μg/kg to 106 μg/kg. Good precision and linearity were observed for most of the mycotoxins. The method was applied for the analysis of naturally contaminated peanut cake, cassava flour and maize samples from the Republic of Benin. All samples analyzed (fifteen peanut cakes, four maize flour and four cassava flour samples) tested positive for one or more mycotoxins. Aflatoxins (total aflatoxins; 10-346 μg/kg) and ochratoxin A (cake samples while fumonisin B(1) (4-21 μg/kg), aflatoxin B(2) (flour samples. Fumonisin B(1) (13-836 μg/kg), fumonisin B(2) (5-221 μg/kg), fumonisin B(3) (

  10. Solid phase microextraction headspace sampling of chemical warfare agent contaminated samples : method development for GC-MS analysis

    Energy Technology Data Exchange (ETDEWEB)

    Jackson Lepage, C.R.; Hancock, J.R. [Defence Research and Development Canada, Medicine Hat, AB (Canada); Wyatt, H.D.M. [Regina Univ., SK (Canada)

    2004-07-01

    Defence R and D Canada-Suffield (DRDC-Suffield) is responsible for analyzing samples that are suspected to contain chemical warfare agents, either collected by the Canadian Forces or by first-responders in the event of a terrorist attack in Canada. The analytical techniques used to identify the composition of the samples include gas chromatography-mass spectrometry (GC-MS), liquid chromatography-mass spectrometry (LC-MS), Fourier-transform infrared spectroscopy (FT-IR) and nuclear magnetic resonance spectroscopy. GC-MS and LC-MS generally require solvent extraction and reconcentration, thereby increasing sample handling. The authors examined analytical techniques which reduce or eliminate sample manipulation. In particular, this paper presented a screening method based on solid phase microextraction (SPME) headspace sampling and GC-MS analysis for chemical warfare agents such as mustard, sarin, soman, and cyclohexyl methylphosphonofluoridate in contaminated soil samples. SPME is a method which uses small adsorbent polymer coated silica fibers that trap vaporous or liquid analytes for GC or LC analysis. Collection efficiency can be increased by adjusting sampling time and temperature. This method was tested on two real-world samples, one from excavated chemical munitions and the second from a caustic decontamination mixture. 7 refs., 2 tabs., 3 figs.

  11. [SciELO: method for electronic publishing].

    Science.gov (United States)

    Laerte Packer, A; Rocha Biojone, M; Antonio, I; Mayumi Takemaka, R; Pedroso García, A; Costa da Silva, A; Toshiyuki Murasaki, R; Mylek, C; Carvalho Reisl, O; Rocha F Delbucio, H C

    2001-01-01

    It describes the SciELO Methodology Scientific Electronic Library Online for electronic publishing of scientific periodicals, examining issues such as the transition from traditional printed publication to electronic publishing, the scientific communication process, the principles which founded the methodology development, its application in the building of the SciELO site, its modules and components, the tools use for its construction etc. The article also discusses the potentialities and trends for the area in Brazil and Latin America, pointing out questions and proposals which should be investigated and solved by the methodology. It concludes that the SciELO Methodology is an efficient, flexible and wide solution for the scientific electronic publishing.

  12. MS-Based Analytical Techniques: Advances in Spray-Based Methods and EI-LC-MS Applications

    Science.gov (United States)

    Medina, Isabel; Cappiello, Achille; Careri, Maria

    2018-01-01

    Mass spectrometry is the most powerful technique for the detection and identification of organic compounds. It can provide molecular weight information and a wealth of structural details that give a unique fingerprint for each analyte. Due to these characteristics, mass spectrometry-based analytical methods are showing an increasing interest in the scientific community, especially in food safety, environmental, and forensic investigation areas where the simultaneous detection of targeted and nontargeted compounds represents a key factor. In addition, safety risks can be identified at the early stage through online and real-time analytical methodologies. In this context, several efforts have been made to achieve analytical instrumentation able to perform real-time analysis in the native environment of samples and to generate highly informative spectra. This review article provides a survey of some instrumental innovations and their applications with particular attention to spray-based MS methods and food analysis issues. The survey will attempt to cover the state of the art from 2012 up to 2017.

  13. Precolumn derivatization LC–MS/MS method for the determination and pharmacokinetic study of glucosamine in human plasma and urine

    Directory of Open Access Journals (Sweden)

    Min Song

    2012-02-01

    Full Text Available A selective precolumn derivatization liquid chromatography–tandem mass spectrometric (LC–MS/MS method for the determination of glucosamine in human plasma and urine has been developed and validated. Glucosamine was derivatized by o-phthalaldehyde/3-mercaptopropionic acid. Chromatographic separation was performed on a Phenomenex ODS column (150 mm×4.6 mm, 5 μm using linear gradient elution by a mobile phase consisting of methanol (A, and an aqueous solution containing 0.2% ammonium acetate and 0.1% formic acid (B at a flow rate of 1 mL/min. Tolterodine tartrate was used as the internal standard (IS. With protein precipitation by acetonitrile and then the simple one-step derivatization, a sensitive bio-assay was achieved with the lower limit of quantitation (LLOQ as low as 12 ng/mL for plasma. The standard addition calibration curves suitable for clinical sample analysis showed good linearity over the range of 0.012–8.27 μg/mL in plasma and 1.80–84.1 μg/mL in urine. The fully validated method has been successfully applied to a pharmacokinetic study of compound glucosamine sulfate dispersible tablets in health Chinese volunteers receiving single oral doses at 500, 1000 and 1500 mg of glucosamine sulfate, as well as multiple oral doses of 500 mg t.i.d. for 7 consecutive days. Keywords: Glucosamine, Pharmacokinetics, Precolumn derivatization, LC–MS/MS

  14. Development and validation of LC-MS/MS method with multiple reactions monitoring mode for quantification of vanillin and syringaldehyde in plum brandies

    Directory of Open Access Journals (Sweden)

    Tešević Vele

    2014-01-01

    Full Text Available An ultra-performance liquid chromatography-triple quadrupole mass spectrometry (UPLC-QqQ-MS/MS method with multiple reactions monitoring mode (MRM has been developed and validated for quantification of vanillin and syringaldehyde in plum brandy. The method showed good linearity (0.05 to 10 mgL−1 and low limits of detection and quantification (LOD and LOQ were 11.6 µgL−1 and 38.2 µgL−1 for vanillin, and 12.7 µgL−1 and 42.0 µgL−1 for syringaldehyde, respectively. The overall intra-day and inter-day variations were less than 4.21%, and the overall recovery over 93.0%. The correlation coefficients (R2 of the calibration curves were higher than 0.9999. In order to evaluate if the method is suitable for use as a routine analytical tool, in 31 Serbian plum brandy samples vanillin and syringaldehide were determined. [Projekat Ministarstva nauke Republike Srbije, br. 172053

  15. Development and validation of a method for the analysis of Ochratoxin A in roasted coffee by liquid chromatography/electrospray-mass spectrometry in Tandem (LC/ESI-MS/MS

    Directory of Open Access Journals (Sweden)

    Raquel D. C. C. Bandeira

    2012-01-01

    Full Text Available A method using LC/ESI-MS/MS for the quantitative analysis of Ochratoxin A in roasted coffee was described. Linearity was demonstrated (r = 0.9175. The limits of detection and quantification were 1.0 and 3.0 ng g-1, respectively. Trueness, repeatability and intermediate precision values were 89.0-108.8%; 2.4-13.7%; 12.5-17.8%, respectively. To the best of our knowledge, this is the first report in which Ochratoxin A in roasted coffee is analysed by LC/ESI-MS/MS, contributing to the field of mycotoxin analysis, and it will be used for future production of Certified Reference Material.

  16. Quantitation of pregabalin in dried blood spots and dried plasma spots by validated LC-MS/MS methods.

    Science.gov (United States)

    Kostić, Nađa; Dotsikas, Yannis; Jović, Nebojša; Stevanović, Galina; Malenović, Anđelija; Medenica, Mirjana

    2015-05-10

    In this paper, novel LC-MS/MS methods for the determination of antiepileptic drug pregabalin in dried matrix spots (DMS) are presented. This attractive technique of sample collection in micro amount was utilized in the form of dried blood spots (DBS) and dried plasma spots (DPS). Following a pre-column derivatization procedure, using n-propyl chloroformate in the presence of n-propanol, and consecutive liquid-liquid extraction, derivatized pregabalin and its internal standard, 4-aminocyclohexanecarboxylic acid, were detected in positive ion mode by applying two SRM transitions per analyte. A YMC-Pack Octyl column (50mm×4.0mm, 3μm particle size) maintained at 30°C, was utilized with running mobile phase composed of acetonitrile: 0.15% formic acid (85:15, v/v). Flow rate was 550μL/min and total run time 2min. Established methods were fully validated over the concentration range of 0.200-20.0μg/mL for DBS and 0.400-40.0μg/mL for DPS, respectively, while specificity, accuracy, precision, recovery, matrix-effect, stability, dilution integrity and spot homogeneity were found within acceptance criteria. Validated methods were applied for the determination of pregabalin levels in dried blood and plasma samples obtained from patients with epilepsy, after per os administration of commercial capsules. Comparison of drug level in blood and plasma, as well as correction steps undertaken in order to overcome hematocrit issue, when analyzing DBS, are also given. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Study of X-ray transients with Scanning Sky Monitor (SSM) onboard ...

    Indian Academy of Sciences (India)

    M. C. RAMADEVI

    MS received 1 September 2017; accepted 19 December 2017; published online 10 February 2018. Abstract. Scanning Sky Monitor (SSM) onboard AstroSat is an X-ray sky monitor in the ..... 31(2–3), 99. Ramadevi M. C., Seetha S., Babu V. C., Ashoka B. N., Sreeku- mar P. 2006, Optimization of Gas Proportional Coun-.

  18. Development and full validation of an UPLC-MS/MS method for the determination of an anti-allergic indolinone derivative in rat plasma, and application to a preliminary pharmacokinetic study.

    Science.gov (United States)

    Oufir, Mouhssin; Sampath, Chethan; Butterweck, Veronika; Hamburger, Matthias

    2012-08-01

    The natural product (E,Z)-3-(4-hydroxy-3,5-dimethoxybenzylidene)indolin-2-one (indolinone) was identified some years ago as a nanomolar inhibitor of FcɛRI-receptor dependent mast cell degranulation. To further explore the potential of the compound, we established an UPLC-MS/MS assay for dosage in rat plasma. The method was fully validated according to FDA Guidance for industry. Results of this validation and long term stability study demonstrate that the method in lithium heparinized rat plasma is specific, accurate, precise and capable of producing reliable results according to recommendations of international guidelines. The method was validated with a LLOQ of 30.0 ng/mL and an ULOQ of 3000 ng/mL. The response versus concentration data were fitted with a first order polynomial with 1/X(2) weighting. No matrix effect was observed when using three independent sources of rat plasma. The average extraction recovery was consistent over the investigated range. This validation in rat plasma demonstrated that indolinone was stable for 190 days when stored below -65 °C; for 4 days at 10 °C in the autosampler; for 4h at RT, and during three successive freeze/thaw cycles at -65 °C. Preliminary pharmacokinetic data were obtained in male Sprague-Dawley rats (2 mg/kg BW i.v.). Blood samples taken from 0 to 12 h after injection were collected, and data analyzed with WinNonlin. A short half-life (4.30±0.14 min) and a relatively high clearance (3.83±1.46 L/h/kg) were found. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Development of a quantitative multi-compound method for the detection of 14 nitrogen-rich adulterants by LC-MS/MS in food materials.

    Science.gov (United States)

    Frank, Nancy; Bessaire, Thomas; Tarres, Adrienne; Goyon, Alexandre; Delatour, Thierry

    2017-11-01

    The increasing number of food frauds using exogenous nitrogen-rich adulterants to artificially raise the protein content for economically motivated adulteration has demonstrated the need for a robust analytical methodology. This method should be applicable for quality control in operations covering a wide range of analyte concentrations to be able to analyse high levels as usually found in adulteration, as well as low levels due to contamination. The paper describes a LC-MS/MS method covering 14 nitrogen-rich adulterants using a simple and fast sample preparation based on dilution and clean-up by dispersive SPE. Quantification is carried out by isotopic dilution reaching LOQs of 0.05-0.20 mg/kg in a broad range of food matrices (infant formula, liquid milk, dairy ingredient, high protein meal, cereal, infant cereal, and meat/fish powder). Validation of seven commodity groups was performed according to SANCO 12571/2013, giving satisfactory results demonstrating the method's fitness for purpose at the validated range at contamination level. Method ruggedness was further assessed by transferring the developed method into another laboratory devoted to routine testing for quality control. Next to the method description, emphasis is placed on challenges and problems appearing during method development as well as validation. They are discussed in detail and solutions are provided.

  20. EXAFS analysis of cations distribution in structure of Co_1_−_xNi_xFe_2O_4 nanoparticles obtained by hydrothermal method in aloe vera extract solution

    International Nuclear Information System (INIS)

    Wongpratat, Unchista; Maensiri, Santi; Swatsitang, Ekaphan

    2016-01-01

    Graphical abstract: It is obvious from the M–H curves at room temperature of Co_1_−_xNi_xFe_2O_4 (x = 0, 0.25, 0.50, 0.75 and 1.0) nanoparticles that partially substitution of the lower Bohr magneton (2 μ_B) and smaller atomic radii (0.55 Å at A site, 0.69 Å at B site) of Ni"2"+ ions on the higher Bohr magneton (3 μ_B) and larger atomic radii (0.58 Å at A site, 0.74 Å at B site) of Co"2"+ ions can increase the saturation magnetization (M_s) of sample with x = 0.75 to approximately 1.4 times of sample with x = 0, due to the increase of the aspect ratio (surface to volume) of nanoparticles, as a result of particle size decreasing from 37.03 to 12.63 nm. In addition to this, the ferrimagnetic behavior of CoFe_2O_4 has been changed to superparamagnetic behavior with the dramatic decrease of the coercivity from 1365.60 to 63.15 Oe. - Highlights: • Magnetic behavior of Co_1_−_xNi_xFe_2O_4 NPs depends on Ni content and size of NPs. • Distribution of Co"2"+ and Ni"2"+ ions in the structure results in the increase of M_s. • Superparamagnetic behavior is observed with increasing of the aspect ratio. • M_s is increased by a factor 1.4 to a value of 57.57 emu/g in Co_0_._2_5Ni_0_._7_5Fe_2O_4. • H_c is decreased by a factor 20 to a value of 63.15 Oe in Co_0_._2_5Ni_0_._7_5Fe_2O_4. - Abstract: Effect of cations distribution upon EXAFS analysis on magnetic properties of Co_1_−_xNi_xFe_2O_4 (x = 0, 0.25, 0.50, 0.75 and 1.0) nanoparticles prepared by the hydrothermal method in aloe vera extract solution were studied. XRD analysis confirmed a pure phase of cubic spinel ferrite of all samples. Changes in lattice parameter and particle size depended on the Ni content with partial substitution and site distributions of Co"2"+, Ni"2"+ ions of different ionic radii at both tetrahedral and octahedral sites in the crystal structure. Particle sizes of samples estimated by TEM images were found to be in the range of 10.87–62.50 nm. The VSM results at room

  1. The utility of ultra-high performance supercritical fluid chromatography-tandem mass spectrometry (UHPSFC-MS/MS) for clinically relevant steroid analysis.

    Science.gov (United States)

    Storbeck, Karl-Heinz; Gilligan, Lorna; Jenkinson, Carl; Baranowski, Elizabeth S; Quanson, Jonathan L; Arlt, Wiebke; Taylor, Angela E

    2018-05-15

    Liquid chromatography tandem mass spectrometry (LC-MS/MS) assays are considered the reference standard for serum steroid hormone analyses, while full urinary steroid profiles are only achievable by gas chromatography (GC-MS). Both LC-MS/MS and GC-MS have well documented strengths and limitations. Recently, commercial ultra-high performance supercritical fluid chromatography-tandem mass spectrometry (UHPSFC-MS/MS) systems have been developed. These systems combine the resolution of GC with the high-throughput capabilities of UHPLC. Uptake of this new technology into research and clinical labs has been slow, possibly due to the perceived increase in complexity. Here we therefore present fundamental principles of UHPSFC-MS/MS and the likely applications for this technology in the clinical research setting, while commenting on potential hurdles based on our experience to date. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  2. A straightforward method to determine flavouring substances in food by GC-MS

    NARCIS (Netherlands)

    Lopez Sanchez, P.; Sisseren, van M.; Marco, De S.; Jekel, A.A.; Nijs, de W.C.M.; Mol, J.G.J.

    2015-01-01

    A straightforward GC–MS method was developed to determine the occurrence of fourteen flavouring compounds in food. It was successfully validated for four generic types of food (liquids, semi-solids, dry solids and fatty solids) in terms of limit of quantification, linearity, selectivity, matrix

  3. Determination of esculentoside A in dog plasma by LC-MS/MS method: application to pre-clinical pharmacokinetics.

    Science.gov (United States)

    Guan, Xiaoduo; Chang, Huichao; Sun, Fanlu; Chen, Xiaohui; Zhang, Wen; Fan, Guorong

    2013-01-01

    A simple and rapid high performance liquid chromatography electrospray ionization ion-trap tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the quantitative determination of esculentoside A (EsA) in dog plasma using ginsenoside Rg1 as the internal standard (IS). After liquid-liquid extraction (LLE) with n-butanol, the analyte and IS were separated on a Diamonsil C(18) (2.1 mm × 50 mm, 3 μm) column with the mobile phase of methanol-water containing 0.1% acetic acid (70:30, v/v) at a flow rate of 0.2 ml/min. An ion trap mass spectrometer equipped with an electrospray ionization source performed in selected reaction monitoring (SRM) mode was used as the detector. The precursor-product ion transitions were m/z 849.3 [M+Na](+)→m/z 805.3 for EsA and m/z 823.3 [M+Na](+)→m/z 643.3 for IS. The total chromatographic run time was 5 min. The method was sensitive enough with a lower limit of quantitation (LLOQ) of 5 ng/ml and had a good linearity (r(2)>0.997) over the linear range of 5-500 ng/ml. The mean extraction recovery of EsA from spiked plasma samples was over 75%. The intra- and inter-precisions were no more than 8.8% and accuracies were within the range of -4.6 to 8.7%. All the validated data were within the accepted criteria as stated in the FDA bioanalytical method validation guideline. The developed method was suitable for the quantification of EsA and successfully applied to the pharmacokinetic study of EsA after an oral administration to beagle dogs. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Optimized LC-MS/MS Method for the High-throughput Analysis of Clinical Samples of Ivacaftor, Its Major Metabolites, and Lumacaftor in Biological Fluids of Cystic Fibrosis Patients.

    Science.gov (United States)

    Schneider, Elena K; Reyes-Ortega, Felisa; Li, Jian; Velkov, Tony

    2017-10-15

    Defects in the cystic fibrosis trans-membrane conductance regulator (CFTR) are the cause of cystic fibrosis (CF), a disease with life-threatening pulmonary manifestations. Ivacaftor (IVA) and ivacaftor-lumacaftor (LUMA) combination are two new breakthrough CF drugs that directly modulate the activity and trafficking of the defective CFTR-protein. However, there is still a dearth of understanding on pharmacokinetic/pharmacodynamic parameters and the pharmacology of ivacaftor and lumacaftor. The HPLC-MS technique for the simultaneous analysis of the concentrations of ivacaftor, hydroxymethyl-ivacaftor, ivacaftor-carboxylate, and lumacaftor in biological fluids in patients receiving standard ivacaftor or ivacaftor-lumacaftor combination therapy has previously been developed by our group and partially validated to FDA standards. However, to allow the high-throughput analysis of a larger number of patient samples, our group has optimized the reported method through the use of a smaller pore size reverse-phase chromatography column (2.6 µm, C8 100 Å; 50 x 2.1 mm) and a gradient solvent system (0-1 min: 40% B; 1-2 min: 40-70% B; 2-2.7 min: held at 70% B; 2.7-2.8 min: 70-90% B; 2.8-4.0 min: 90% B washing; 4.0-4.1 min: 90-40% B; 4.1-6.0 min: held at 40% B) instead of an isocratic elution. The goal of this study was to reduce the HPLC-MS analysis time per sample dramatically from ~15 min to only 6 min per sample, which is essential for the analysis of a large amount of patient samples. This expedient method will be of considerable utility for studies into the exposure-response relationships of these breakthrough CF drugs.

  5. Chiral liquid chromatography-mass spectrometry (LC-MS/MS) method development for the detection of salbutamol in urine samples.

    Science.gov (United States)

    Chan, Sue Hay; Lee, Warren; Asmawi, Mohd Zaini; Tan, Soo Choon

    2016-07-01

    A sequential solid-phase extraction (SPE) method was developed and validated using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) for the detection and quantification of salbutamol enantiomers in porcine urine. Porcine urine samples were hydrolysed with β-glucuronidase/arylsulfatase from Helix pomatia and then subjected to a double solid-phase extraction (SPE) first using the Abs-Elut Nexus SPE and then followed by the Bond Elut Phenylboronic Acid (PBA) SPE. The salbutamol enantiomers were separated using the Astec CHIROBIOTIC™ T HPLC column (3.0mm×100mm; 5μm) maintained at 15°C with a 15min isocratic run at a flow rate of 0.4mL/min. The mobile phase constituted of 5mM ammonium formate in methanol. Salbutamol and salbutamol-tert-butyl-d9 (internal standard, IS) was monitored and quantified with the multiple reaction monitoring (MRM) mode. The method showed good linearity for the range of 0.1-10ng/mL with limit of quantification at 0.3ng/mL. Analysis of the QC samples showed intra- and inter-assay precisions to be less than 5.04%, and recovery ranging from 83.82 to 102.33%. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Multi-Segment Direct Inject nano-ESI-LTQ-FT-ICR-MS/MS For Protein Identification

    Directory of Open Access Journals (Sweden)

    Neal Rachel E

    2011-07-01

    Full Text Available Abstract Reversed phase high performance liquid chromatography (HPLC interfaced to electrospray tandem mass spectrometry (MS/MS is commonly used for the identification of peptides from proteolytically cleaved proteins embedded in a polyacrylamide gel matrix as well as for metabolomics screening. HPLC separations are time consuming (30-60 min average, costly (columns and mobile phase reagents, and carry the risk of column carry over between samples. The use of a chip-based nano-ESI platform (Advion NanoMate based on replaceable nano-tips for sample introduction eliminates sample cross-contamination, provides unchanging sample matrix, and enhances spray stability with attendant increases in reproducibility. Recent papers have established direct infusion nano-ESI-MS/MS utilizing the NanoMate for protein identification of gel spots based on full range MS scans with data dependent MS/MS. In a full range scan, discontinuous ion suppression due to sample matrix can impair identification of putative mass features of interest in both the proteomic and metabolomic workflows. In the current study, an extension of an established direct inject nano-ESI-MS/MS method is described that utilizes the mass filtering capability of an ion-trap for ion packet separation into four narrow mass ranges (50 amu overlap with segment specific dynamic data dependent peak inclusion for MS/MS fragmentation (total acquisition time of 3 minutes. Comparison of this method with a more traditional nanoLC-MS/MS based protocol utilizing solvent/sample stream splitting to achieve nanoflow demonstrated comparable results for protein identification from polyacrylamide gel matrices. The advantages of this method include full automation, lack of cross-contamination, low cost, and high throughput.

  7. Envelope composition of Salmonella typhimurium 395 MS and 395 MR10 assesses by X-ray photoelectron spectroscopy (ESCA)

    International Nuclear Information System (INIS)

    Magnusson, K.F.; Johansson, L.

    1977-01-01

    The Salmonella typhimurium 395 MS and MR10 bacteria and lipopolysaccharide (LPS) were studied by X-ray photoelectron spectroscopy with the aid of the ESCA technique for the in situ analysis of chemical elements (C, O and N) at the surface. The nitrogen peak was large in both bacteria implying the presence of protein in the very outer part of the bacterial envelope due to the surface-sensitive measurement. The nitrogen peak was larger in the MR10 than in the MS bacteria, presumably reflecting an increased exposure of proteins concomitantly with the reduction of the LPS in MR10. After corrections for background and sensitivity of detection the relative intensities of the peaks agreed appreciably well with the proposed chemical structure of the LPS, indicating that at least semiquantitative relationships between the elements were obtained. (author)

  8. A fast and simple GC MS method for lignan profiling in Anthriscus sylvestris and biosynthetically related plant species

    NARCIS (Netherlands)

    Koulman, A; Bos, R; Medarde, M; Pras, N; Quax, WJ

    2001-01-01

    A new GC-MS method for monitoring lignans was developed to study the variation in plants and elucidate the biosynthetic steps. A simple and fast extraction procedure for lyophilised plant material was developed, giving a lignan-rich extract. A GC-MS method was set up using an apolar WCOT fused

  9. A sensitive, simple and rapid HPLC–MS/MS method for simultaneous quantification of buprenorpine and its N-dealkylated metabolite norbuprenorphine in human plasma

    Directory of Open Access Journals (Sweden)

    Yi-Ya Wang

    2013-08-01

    Full Text Available A sensitive, simple and rapid high performance liquid chromatography-tandem mass spectrometry (HPLC–MS/MS method was developed and fully validated for the simultaneous quantification of buprenorphine (BUP and its N-dealkylated metabolite norbuprenorphine (NBUP in 200μL human plasma. Human plasma samples were prepared using liquid–liquid extraction, and then separated on a Shiseido MG C18 (5μm, 2.0mm×50mm via 4.1min gradient elution. Following electrospray ionization, the analytes were quantified on a triple–quadrupole mass spectrometer in multiple-reaction-monitoring (MRM positive ion mode. Linearity was achieved from 25.0 to 10000pg/mL for buprenorphine, from 20.0 to 8000pg/mL for norbuprenorphine with r2>0.99. The method was demonstrated with acceptable accuracy, precision and specificity for the detection of buprenorphine and norbuprenorphine. Recovery was 81.8–88.8% for buprenorphine and 77.0–84.6% for norbuprenorphine, and the matrix effect was 95.6–97.4% for buprenorphine and 94.0–96.9% for norbuprenorphine; all were not concentration dependent. With validated matrix and autosampler stability data, this method was successfully applied in a bioequivalence study to support abbreviated new drug application. Keywords: Buprenorphine, Norbuprenorphine, Human plasma, HPLC–MS/MS

  10. Validation of a LC-MS/MS method for quantifying urinary nicotine, six nicotine metabolites and the minor tobacco alkaloids--anatabine and anabasine--in smokers' urine.

    Directory of Open Access Journals (Sweden)

    James E McGuffey

    Full Text Available Tobacco use is a major contributor to premature morbidity and mortality. The measurement of nicotine and its metabolites in urine is a valuable tool for evaluating nicotine exposure and for nicotine metabolic profiling--i.e., metabolite ratios. In addition, the minor tobacco alkaloids--anabasine and anatabine--can be useful for monitoring compliance in smoking cessation programs that use nicotine replacement therapy. Because of an increasing demand for the measurement of urinary nicotine metabolites, we developed a rapid, low-cost method that uses isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS for simultaneously quantifying nicotine, six nicotine metabolites, and two minor tobacco alkaloids in smokers' urine. This method enzymatically hydrolyzes conjugated nicotine (primarily glucuronides and its metabolites. We then use acetone pretreatment to precipitate matrix components (endogenous proteins, salts, phospholipids, and exogenous enzyme that may interfere with LC-MS/MS analysis. Subsequently, analytes (nicotine, cotinine, hydroxycotinine, norcotinine, nornicotine, cotinine N-oxide, nicotine 1'-N-oxide, anatabine, and anabasine are chromatographically resolved within a cycle time of 13.5 minutes. The optimized assay produces linear responses across the analyte concentrations typically found in urine collected from daily smokers. Because matrix ion suppression may influence accuracy, we include a discussion of conventions employed in this procedure to minimize matrix interferences. Simplicity, low cost, low maintenance combined with high mean metabolite recovery (76-99%, specificity, accuracy (0-10% bias and reproducibility (2-9% C.V. make this method ideal for large high through-put studies.

  11. Relationship between plasma and salivary melatonin and cortisol investigated by LC-MS/MS.

    Science.gov (United States)

    van Faassen, Martijn; Bischoff, Rainer; Kema, Ido P

    2017-08-28

    Disturbance of the circadian rhythm has been associated with disease states, such as metabolic disorders, depression and cancer. Quantification of the circadian markers such as melatonin and cortisol critically depend on reliable and reproducible analytical methods. Previously, melatonin and cortisol were primarily analyzed separately, mainly using immunoassays. Here we describe the validation and application of a high-throughput liquid chromatography in combination with mass spectrometry (LC-MS/MS) method for the combined analysis of melatonin and cortisol in plasma and saliva. The LC-MS/MS method was validated according to international validation guidelines. We used this method to analyze total plasma, free plasma (as obtained by equilibrium dialysis) and saliva melatonin and cortisol in healthy adults. Validation results for plasma and saliva melatonin and cortisol were well within the international validation criteria. We observed no difference between saliva collected by passive drooling or Salivette. Moreover, we noted a significant difference in saliva vs. free plasma melatonin. We observed on average 36% (95% CI: 4%-60%) higher salivary melatonin levels in comparison to free plasma melatonin, suggestive of local production of melatonin in the salivary glands. The novel outcome of this study is probably due to the high precision of our LC-MS/MS assay. These outcomes illustrate the added value of accurate and sensitive mass spectrometry based methods for the quantification of neuroendocrine biomarkers.

  12. Method for spatially modulating X-ray pulses using MEMS-based X-ray optics

    Science.gov (United States)

    Lopez, Daniel; Shenoy, Gopal; Wang, Jin; Walko, Donald A.; Jung, Il-Woong; Mukhopadhyay, Deepkishore

    2015-03-10

    A method and apparatus are provided for spatially modulating X-rays or X-ray pulses using microelectromechanical systems (MEMS) based X-ray optics. A torsionally-oscillating MEMS micromirror and a method of leveraging the grazing-angle reflection property are provided to modulate X-ray pulses with a high-degree of controllability.

  13. Publishing in Open Access Journals

    International Development Research Centre (IDRC) Digital Library (Canada)

    mbrunet

    00054.x). • An ISSN (International Standard Serial Number e.g. 1234-5678) has ... Publisher uses direct and unsolicited marketing (i.e., spamming) or advertising is obtrusive (to publish articles or serve on editorial board). • No information is ...

  14. Cross-validated stable-isotope dilution GC-MS and LC-MS/MS assays for monoacylglycerol lipase (MAGL) activity by measuring arachidonic acid released from the endocannabinoid 2-arachidonoyl glycerol.

    Science.gov (United States)

    Kayacelebi, Arslan Arinc; Schauerte, Celina; Kling, Katharina; Herbers, Jan; Beckmann, Bibiana; Engeli, Stefan; Jordan, Jens; Zoerner, Alexander A; Tsikas, Dimitrios

    2017-03-15

    2-Arachidonoyl glycerol (2AG) is an endocannabinoid that activates cannabinoid (CB) receptors CB1 and CB2. Monoacylglycerol lipase (MAGL) inactivates 2AG through hydrolysis to arachidonic acid (AA) and glycerol, thus modulating the activity at CB receptors. In the brain, AA released from 2AG by the action of MAGL serves as a substrate for cyclooxygenases which produce pro-inflammatory prostaglandins. Here we report stable-isotope GC-MS and LC-MS/MS assays for the reliable measurement of MAGL activity. The assays utilize deuterium-labeled 2AG (d 8 -2AG; 10μM) as the MAGL substrate and measure deuterium-labeled AA (d 8 -AA; range 0-1μM) as the MAGL product. Unlabelled AA (d 0 -AA, 1μM) serves as the internal standard. d 8 -AA and d 0 -AA are extracted from the aqueous buffered incubation mixtures by ethyl acetate. Upon solvent evaporation the residue is reconstituted in the mobile phase prior to LC-MS/MS analysis or in anhydrous acetonitrile for GC-MS analysis. LC-MS/MS analysis is performed in the negative electrospray ionization mode by selected-reaction monitoring the mass transitions [M-H] - →[M-H - CO 2 ] - , i.e., m/z 311→m/z 267 for d 8 -AA and m/z 303→m/z 259 for d 0 -AA. Prior to GC-MS analysis d 8 -AA and d 0 -AA were converted to their pentafluorobenzyl (PFB) esters by means of PFB-Br. GC-MS analysis is performed in the electron-capture negative-ion chemical ionization mode by selected-ion monitoring the ions [M-PFB] - , i.e., m/z 311 for d 8 -AA and m/z 303 for d 0 -AA. The GC-MS and LC-MS/MS assays were cross-validated. Linear regression analysis between the concentration (range, 0-1μM) of d 8 -AA measured by LC-MS/MS (y) and that by GC-MS (x) revealed a straight line (r 2 =0.9848) with the regression equation y=0.003+0.898x, indicating a good agreement. In dog liver, we detected MAGL activity that was inhibitable by the MAGL inhibitor JZL-184. Exogenous eicosatetraynoic acid is suitable as internal standard for the quantitative determination

  15. Determination of urinary aromatic amines in smokers and nonsmokers using a MIPs-SPE coupled with LC-MS/MS method.

    Science.gov (United States)

    Yu, Jingjing; Wang, Sheng; Zhao, Ge; Wang, Bing; Ding, Li; Zhang, Xiaobing; Xie, Jianping; Xie, Fuwei

    2014-05-01

    Urinary aromatic amines (AAs) could be used as biomarkers for human exposure to AAs in cigarette smoke. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of urinary AAs (i.e. 1-naphthylamine (1-NA), 2-naphthylamine (2-NA), 3-aminobiphenyl (3-ABP) and 4-aminobiphenyl (4-ABP)) in smokers and nonsmokers. A molecularly imprinted polymers (MIPs) solid phase extraction (SPE) cartridge was applied to purify urine samples and no derivatization reaction was involved. Each analytes used respective stable isotope internal standards, which could well compensate matrix effect. Lower limit of detections (LODs) for four AAs were obtained and in the range of 1.5-5ngL(-1). Recovery ranged from 87.7±4.5% to 111.3±6.4% and precision were less than 9.9%. The method was applied to analyze urine samples of 40 smokers and 10 nonsmokers. The 24h urinary excretion amounts of total AAs were higher for smokers compared with nonsmokers. What's more, 1-NA, 3-ABP and 4-ABP excretion amounts showed significant differences (p<0.05) between smokers and nonsmokers. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. The EIPeptiDi tool: enhancing peptide discovery in ICAT-based LC MS/MS experiments

    Directory of Open Access Journals (Sweden)

    Tradigo Giuseppe

    2007-07-01

    Full Text Available Abstract Background Isotope-coded affinity tags (ICAT is a method for quantitative proteomics based on differential isotopic labeling, sample digestion and mass spectrometry (MS. The method allows the identification and relative quantification of proteins present in two samples and consists of the following phases. First, cysteine residues are either labeled using the ICAT Light or ICAT Heavy reagent (having identical chemical properties but different masses. Then, after whole sample digestion, the labeled peptides are captured selectively using the biotin tag contained in both ICAT reagents. Finally, the simplified peptide mixture is analyzed by nanoscale liquid chromatography-tandem mass spectrometry (LC-MS/MS. Nevertheless, the ICAT LC-MS/MS method still suffers from insufficient sample-to-sample reproducibility on peptide identification. In particular, the number and the type of peptides identified in different experiments can vary considerably and, thus, the statistical (comparative analysis of sample sets is very challenging. Low information overlap at the peptide and, consequently, at the protein level, is very detrimental in situations where the number of samples to be analyzed is high. Results We designed a method for improving the data processing and peptide identification in sample sets subjected to ICAT labeling and LC-MS/MS analysis, based on cross validating MS/MS results. Such a method has been implemented in a tool, called EIPeptiDi, which boosts the ICAT data analysis software improving peptide identification throughout the input data set. Heavy/Light (H/L pairs quantified but not identified by the MS/MS routine, are assigned to peptide sequences identified in other samples, by using similarity criteria based on chromatographic retention time and Heavy/Light mass attributes. EIPeptiDi significantly improves the number of identified peptides per sample, proving that the proposed method has a considerable impact on the protein

  17. Application of CE-ICP-MS and CE-ESI-MS/MS for identification of Zn-binding ligands in Goji berries extracts.

    Science.gov (United States)

    Ruzik, Lena; Kwiatkowski, Piotr

    2018-06-01

    The identification of groups of ligands binding metals is a crucial issue for the better understanding of their bioaccessibility. In the current study, we have intended an approach for identification of Zn-binding ligands based on using capillary electrophoresis combined with inductively coupled plasma mass spectrometry (CE-ICP-MS) and tandem electrospray ionization mass spectrometry (CE-ESI-MS/MS). The approach, which featured the use of the coupling of capillary electrophoresis with inductively coupled plasma mass spectrometry allows to separate and observe zinc ions present in complexes with respect to their size and charge and to identify nine compounds with zinc isotopic profile. CE-ICP-MS provides us with information about presence of zinc species and elemental information about zinc distribution. CE-ESI-MS/MS provide us with information about the most favorable Zn binding ligands: amino acids, flavonols, stilbenoids, fenolic acids and carotenoids. The presented work is the continuation of previous studies based on using LC-ESI-MS/MS, though, now we presented a new solutions with the possibility of changing detectors without changing the separation techniques, what is important without re-optimizing the method. The new presented method allows to identify the zinc-binding ligands in shorter time. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Development and validation of a HPLC-MS/MS method for the determination of phytolaccagenin in rat plasma and application to a pharmacokinetic study.

    Science.gov (United States)

    Wei, Fenghuan; Singh, Ravi Shankar Prasad; Fueth, Matthias; Swarts, Steven; Okunieff, Paul; Derendorf, Hartmut

    2015-03-25

    Radix Phytolaccae (the dried root of Phytolacca acinosa Roxb. or Phytolacca americana L.) is widely used in East Asian countries for the treatment of inflammation-related diseases. The active component of Radix Phtolaccae is Phytolcaccagenin a triterpenoid saponin. Phytolcaccagenin has anti-inflammatory activities that exceed those of Esculentoside A and its derivatives regarding suppression of LPS-induced inflammation, and has a lower toxicity profile with less hemolysis. To date, no information is available about analytical method and pharmacokinetic studies of phytolaccagenin. To explore PK profile of this compound, a HPLC-MS/MS assay of phytolaccagenin in rat plasma was developed and validated. The method was fully validated according to FDA Guidance for industry. The detection was performed by a triple-quadrupole tandem mass spectrometer with multiple reactions monitoring (MRM) in positive ion mode via electrospray ionization. The monitored transitions were m/z 533.2>515.3 for Phytolcaccagenin, and 491.2>473.2 for I.S. The analysis was performed on a Symmetry C18 column (4.6 mm × 50 mm, 3.5 μm) using gradient elution with the mobile phase consisting of acetonitrile and 0.1% formic acid water at a flow rate of 1 ml/min with a 1:1 splitter ratio. The method was validated with a LLOQ of 20 ng/ml and an ULOQ of 1000 ng/ml. The response versus concentration data were fitted with 1/x weighting and the correlation coefficient (r) were greater than 0.999. The average matrix effect and the average extraction recovery were acceptable. This validation in rat plasma demonstrated that phytolaccagenin was stable for 30 days when stored below -20°C, for 6h at room temperature (RT, 22°C), for 12 h at RT for prepared control samples in auto-sampler vials, and during three successive freeze/thaw cycles results at -20°C. The validated method has been successfully applied to an intravenous bolus pharmacokinetic study of phytolaccagenin in male Sprague-Dawley rats (10 mg

  19. Pyrrolizidine alkaloids in the food chain: development, validation, and application of a new HPLC-ESI-MS/MS sum parameter method.

    Science.gov (United States)

    Cramer, Luise; Schiebel, Hans-Martin; Ernst, Ludger; Beuerle, Till

    2013-11-27

    Contamination of food and feed with pyrrolizidine alkaloids is currently discussed as a potential health risk. Here, we report the development of a new HPLC-ESI-MS/MS sum parameter method to quantitate the pyrrolizidine alkaloid content in complex food matrices. The procedure was validated for honey and culinary herbs. Isotopically labeled 7-O-9-O-dibutyroyl-[9,9-(2)H2]-retronecine was synthesized and utilized as an internal standard for validation and quantitation. The total pyrrolizidine alkaloid content of a sample is expressed as a single sum parameter: retronecine equivalents (RE). Ld/Lq for honey was 0.1 μg RE/kg/0.3 μg RE/kg. For culinary herbs, 1.0 μg RE/kg/3.0 μg RE/kg (dry weight, dw) and 0.1 μg RE/kg/0.3 μg RE/kg (fresh weight, fw) were determined, respectively. The new method was applied to analyze 21 herbal convenience products. Fifteen products (71%) were pyrrolizidine alkaloid positive showing pyrrolizidine alkaloid concentrations ranging from 0.9 to 74 μg RE/kg fw.

  20. A Novel LC-MS-MS Method With an Effective Antioxidant for the Determination of Edaravone, a Free-Radical Scavenger in Dog Plasma and its Application to a Pharmacokinetic Study.

    Science.gov (United States)

    Shao, Feng; Hu, Xiao-Ling; Liu, Xin; Shan, Mang-Ting

    2017-07-01

    The objective of this study was to investigate the stability of edaravone in dog plasma by using an added antioxidant stabilizer, with an ultimate goal of developing and validating a sensitive, reliable and robust LC-MS-MS method for determination of edaravone in plasma samples. Edaravone was unstable in plasma, but it presented a good stability performance in the plasma with sodium metabisulfite (SMB), an effective antioxidant. The blood sample was collected in the heparinized eppendorf tube containing SMB and plasma sample was deproteinized using acetonitrile containing 20 ng/mL of phenacetin (Internal standard). The chromatographic separation was performed on a Zorbax Extend-C18 analytical column (2.1 mm × 150 mm I.D., particle size 3.5 µm, Agilent Technologies, USA). The mobile phase consisted of 0.1% formic acid in water (v/v) and methanol, and gradient elution was used. The analyte detection was performed on a triple quadrupole tandem mass spectrometer equipped with positive-ion electrospray ionization by multiple reaction ion monitoring mode of the transitions at m/z [M + H]+ 175.1 → 77.1 for edaravone, and m/z [M + H]+ 180.2 → 110.0 for phenacetin. The linearity of this method was within the concentration range of 10-1000 ng/mL for edaravone in dog plasma. The lower limit of quantification was 10 ng/mL. The relative standard deviations of intra- and inter-precision were edaravone in beagle dogs after intravenous administration. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Qualitative and quantitative analysis of flavonoids in Sophora tonkinensis by LC/MS and HPLC.

    Science.gov (United States)

    He, Chang-Ming; Cheng, Zhi-Hong; Chen, Dao-Feng

    2013-11-01

    To develop analytical methods for the identification and determination of the flavonoids in Sophora tonkinensis for comprehensive quality evaluation. An HPLC-DAD-ESI-MS method was used for the separation and characterization of the flavonoids in S. tonkinensis, and a liquid chromatographic method was employed to simultaneously determine five major active flavonoids in this crude drug. Seventeen flavonoids were identified, among which, seven were unambiguously identified as trifolirhizin, quercetin, formononetin, macckiain, kurarinone, sophoranone, and sophoranochromene by comparing their retention times, and UV and MS spectra with those of the authentic compounds, and the other ten flavonoids were tentatively identified by comparing their UV and MS/MS spectra with those of literature data. Furthermore, five major active flavonoids, including trifolirhizin, quercetin, maackiain, sophoranone, and sophoranochromene were determined in S. tonkinensis. All calibration curves expressed good linearity (r > 0.999 8) within the test ranges, and the recovery from this method was 96.40%-104.43%. The developed HPLC method was successfully applied to quantitatively determine the five flavonoids in seventeen samples of S. tonkinensis. The developed method rapidly characterized the bioactive flavonoids of S. tonkinensis, and could be readily utilized to enhance the quality assurance approaches for this traditional Chinese medicine. Copyright © 2013 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.

  2. Identification of Eight Synthetic Cannabinoids, Including 5F-AKB48 in Seized Herbal Products Using DART-TOF-MS and LC-QTOF-MS as Nontargeted Screening Methods.

    Science.gov (United States)

    Moore, Katherine N; Garvin, Demetra; Thomas, Brian F; Grabenauer, Megan

    2017-09-01

    Synthetic cannabinoids are sprayed onto plant material and smoked for their marijuana-like effects. Clandestine manufacturers modify synthetic cannabinoid structures by creating closely related analogs. Forensic laboratories are tasked with detection of these analog compounds, but targeted analytical methods are often thwarted by the structural modifications. Here, direct analysis in real time coupled to accurate mass time-of-flight mass spectrometry (DART-TOF-MS) in combination with liquid chromatography quadruple time-of-flight mass spectrometry (LC-QTOF-MS) are presented as a screening and nontargeted confirmation method, respectively. Methanol extracts of herbal material were run using both methods. Spectral data from four different herbal products were evaluated by comparing fragmentation pattern, accurate mass and retention time to available reference standards. JWH-018, JWH-019, AM2201, JWH-122, 5F-AKB48, AKB48-N-(4-pentenyl) analog, UR144, and XLR11 were identified in the products. Results demonstrate that DART-TOF-MS affords a useful approach for rapid screening of herbal products for the presence and identification of synthetic cannabinoids. © 2017 American Academy of Forensic Sciences.

  3. LC-MS/MS method for the simultaneous determination of PA-824, moxifloxacin and pyrazinamide in rat plasma and its application to pharmacokinetic study.

    Science.gov (United States)

    Wang, Libin; Xu, Yue; Liang, Li; Diao, Chunyan; Liu, Xueying; Zhang, Jianchun; Zhang, Shengyong

    2014-08-01

    A simple, sensitive and rapid LC-MS/MS method has been developed and validated for simultaneous determination of PA-824, moxifloxacin, and pyrazinamide in rat plasma using metronidazole as internal standard. Sample preparation involved a simple one-step protein precipitation with methanol, followed by centrifugation and evaporation of the organic solvent. The residue was redissolved in mobile phase and analyzed by LC-MS/MS. An Inertsil(®) ODS3 C18 column (150mm×4.6mm, 5μm), a mobile phase composed of methanol-0.03% TEA (triethylamine) in water (85:15, v/v), and a flow rate of 0.5mL/min were employed, and the total run time was 6.0min. The mass spectrometer was run in positive ion ESI-APCI combined mode using multiple reaction monitoring (MRM) to monitor the mass transitions. The method was validated for accuracy, precision, linearity, range, selectivity, lower limit of quantification (LLOQ), recovery, and matrix effect. All validation parameters met the acceptance criteria according to regulatory guidelines. The LLOQ was 1.0μg/mL for pyrazinamide and 0.1μg/mL for PA-824 and moxifloxacin. The recoveries obtained for PA-824, moxifloxacin and pyrazinamide were ≥85%. Intra-day and inter-day coefficients of variation were less than 10%. The method had been successfully applied to a pharmacokinetic study of fixed dose administration of PA-824, moxifloxacin, pyrazinamide and their combination in SD rat. Significant differences of Tmax, Cmax, AUC(0-t) and CLz/F were observed between the single and combined groups after equal dose of PA-824 and moxifloxacin administration, which revealed the possibility of drug-drug interaction (DDI) between the PaMZ combination. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Ultra-sensitive LC-MS/MS method for the quantification of gemcitabine and its metabolite 2',2'-difluorodeoxyuridine in human plasma for a microdose clinical trial.

    Science.gov (United States)

    van Nuland, M; Hillebrand, M J X; Rosing, H; Burgers, J A; Schellens, J H M; Beijnen, J H

    2018-03-20

    In microdose clinical trials a maximum of 100 μg of drug substance is administered to participants, in order to determine the pharmacokinetic properties of the agents. Measuring low plasma concentrations after administration of a microdose is challenging and requires the use of ulta-sensitive equipment. Novel liquid chromatography-mass spectrometry (LC-MS/MS) platforms can be used for quantification of low drug plasma levels. Here we describe the development and validation of an LC-MS/MS method for quantification of gemcitabine and its metabolite 2',2'-difluorodeoxyuridine (dFdU) in the low picogram per milliliter range to support a microdose trial. The validated assay ranges from 2.5-500 pg/mL for gemcitabine and 250-50,000 pg/mL for dFdU were linear, with a correlation coefficient (r 2 ) of 0.996 or better. Sample preparation with solid phase extraction provided a good and reproducible recovery. All results were within the acceptance criteria of the latest US FDA guidance and EMA guidelines. In addition, the method was successfully applied to measure plasma concentrations of gemcitabine in a patient after administration of a microdose of gemcitabine. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. A High-Throughput UHPLC-QqQ-MS Method for Polyphenol Profiling in Rosé Wines

    Directory of Open Access Journals (Sweden)

    Marine Lambert

    2015-04-01

    Full Text Available A rapid, sensitive and selective analysis method using Ultra High Performance Liquid Chromatography coupled to triple-quadrupole Mass Spectrometry (UHPLC-QqQ-MS has been developed for the quantification of polyphenols in rosé wines. The compound detection being based on specific MS transitions in Multiple Reaction Monitoring (MRM mode, the present method allows the selective quantification of up to 152 phenolic and two additional non-phenolic wine compounds in 30 min without sample purification or pre-concentration, even at low concentration levels. This method was repeatably applied to a set of 12 rosé wines and thus proved to be suitable for high-throughput and large-scale metabolomics studies.

  6. A reliable and validated LC-MS/MS method for the simultaneous quantification of 4 cannabinoids in 40 consumer products.

    Directory of Open Access Journals (Sweden)

    Qingfang Meng

    Full Text Available In the past 50 years, Cannabis sativa (C. sativa has gone from a substance essentially prohibited worldwide to one that is gaining acceptance both culturally and legally in many countries for medicinal and recreational use. As additional jurisdictions legalize Cannabis products and the variety and complexity of these products surpass the classical dried plant material, appropriate methods for measuring the biologically active constituents is paramount to ensure safety and regulatory compliance. While there are numerous active compounds in C. sativa the primary cannabinoids of regulatory and safety concern are (--Δ⁹-tetrahydrocannabinol (THC, cannabidiol (CBD, and their respective acidic forms THCA-A and CBDA. Using the US Food and Drug Administration (FDA bioanalytical method validation guidelines we developed a sensitive, selective, and accurate method for the simultaneous analysis CBD, CBDA, THC, and THCA-A in oils and THC & CBD in more complex matrices. This HPLC-MS/MS method was simple and reliable using standard sample dilution and homogenization, an isocratic chromatographic separation, and a triple quadrupole mass spectrometer. The lower limit of quantification (LLOQ for analytes was 0.195 ng/mL over a 0.195-50.0 ng/mL range of quantification with a coefficient of correlation of >0.99. Average intra-day and inter-day accuracies were 94.2-112.7% and 97.2-110.9%, respectively. This method was used to quantify CBD, CBDA, THC, and THCA-A in 40 commercial hemp products representing a variety of matrices including oils, plant materials, and creams/cosmetics. All products tested met the federal regulatory restrictions on THC content in Canada (1,000 (an oil-based product. Overall, the method proved amenable to the analysis of various commercial products including oils, creams, and plant material and may be diagnostically indicative of adulteration with non-hemp C. sativa, specialized hemp cultivars, or unique manufacturing methods.

  7. Effect of Microstructure on HIC Susceptibility of API X70MS Linepipe Steel

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Joon-Ho; Sim, Ho-Seop; Park, Byung-Gyu [Dongkuk Steel R and D Center, Pohang (Korea, Republic of); Cho, Kyung-Mox [Pusan National University, Busan (Korea, Republic of)

    2017-06-15

    The resistance of hydrogen induced cracking (HIC) was investigated with different microstructures of API X70MS steel. Ferrite/acicular ferrite (F/AF), deformed ferrite/acicular ferrite, ferrite/bainite (F/B) and single acicular ferrite (AF) were obtained by thermo-mechanical controlled process (TMCP) with changing rolling and cooling conditions. HIC resistance was found to be affected by the type as well as morphology of the microstructure, and thus the behavior of crack initiation and propagation could be analyzed. It was found that single AF and deformed F/AF with uniformly distributed dislocation reduced HIC initiation. Banded microstructure with a hardness value below 250 HV, such as AF, showed good HIC propagation resistance due to high toughness. AF generally exhibited excellent crack initiation and propagation resistance, namely the best HIC susceptibility performance. AF might redeem the HIC resistance for the banded microstructure also.

  8. ANALYSIS METHOD OF RESEARCH PAPERS PUBLISHED FOR AUDIT

    Directory of Open Access Journals (Sweden)

    GREAVU-ȘERBAN VALERICĂ

    2015-08-01

    Full Text Available Representing a strong instrument of control and feedback used by top management executives, regulators institutions or independent bodies, the audit, its methods and techniques incite the interest of specialists, professionals, professors and researchers from all socio-economic activities. The way domain experts write about audit itself is often reflected in the manner in which they choose the keywords for the title and for the article. This study is a detailed analysis of assignment to the specific thematic areas of articles published in "Financial Audit" journal, for all public appearances in electronic format from the period 2003-2015. The study is different from other similar researches by the methodology and the type of information extracted addressed. The main purpose is to identify the most used keywords in the title and content of articles published over time and insight traceability to future research directions. The conclusions of the analysis from this article give a comprehensive picture of audit multidisciplinary, thus providing researchers, on several economic fields, an image about the content of the publication, quality information for readers, authors and future authors.

  9. Metabolic profiling of roots of liquorice (Glycyrrhiza glabra) from different geographical areas by ESI/MS/MS and determination of major metabolites by LC-ESI/MS and LC-ESI/MS/MS.

    Science.gov (United States)

    Montoro, Paola; Maldini, Mariateresa; Russo, Mariateresa; Postorino, Santo; Piacente, Sonia; Pizza, Cosimo

    2011-02-20

    Liquid chromatography electrospray mass spectrometry (LC-ESI/MS) has been applied to the full characterization of saponins and phenolics in hydroalcoholic extracts of roots of liquorice (Glycyrrhiza glabra). Relative quantitative analyses of the samples with respect to the phenolic constituents and to a group of saponins related to glycyrrhizic acid were performed using LC-ESI/MS. For the saponin constituents, full scan LC-MS/MS fragmentation of the protonated (positive ion mode) or deprotonated (negative ion mode) molecular species generated diagnostic fragment ions that provided information concerning the triterpene skeleton and the number and nature of the substituents. On the basis of the specific fragmentation of glycyrrhizic acid, an LC-MS/MS method was developed in order to quantify the analyte in the liquorice root samples. Chinese G. glabra roots contained the highest levels of glycyrrhizic acid, followed by those from Italy (Calabria). Copyright © 2010 Elsevier B.V. All rights reserved.

  10. A high-throughput method for the simultaneous determination of multiple mycotoxins in human and laboratory animal biological fluids and tissues by PLE and HPLC-MS/MS.

    Science.gov (United States)

    Cao, Xiaoqin; Wu, Shuangchan; Yue, Yuan; Wang, Shi; Wang, Yuting; Tao, Li; Tian, Hui; Xie, Jianmei; Ding, Hong

    2013-12-30

    A high-throughput method for the determination of 28 mycotoxins involving pressurised liquid extraction (PLE) coupled with liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) has been optimised and validated for determination in various biological fluids and tissues of human and laboratory animals. High-throughput analysis was achieved using PLE pre-treatment and without the need for any cleanup. The extraction solvent was acetonitrile/water/acetic acid (80/19/1, v/v/v). The static extraction time was 5min. The extraction pressure and temperature were 1500psi and 140°C, respectively. The flush volume was 60%. The limits of detection, which were defined as CCα, varied from 0.01μg/kg (μg/L) to 0.69μg/kg (μg/L). The recoveries of spiked samples from 0.20μg/kg (μg/L) to 2μg/kg (μg/L) ranged from 71% to 100.5% with relative standard deviations of less than 17.5%, except FB1 and FB2 recoveries, which were lower than 60%. The method was successfully applied in real samples, and the data indicate that this technique is a useful analytical method for the determination of mycotoxins from humans and animals. To the best of our knowledge, this method is the first for the large-scale testing of multi-class mycotoxins in all types of biological fluids and tissues that uses PLE and HPLC-MS/MS. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Differentiation of wines according to grape variety and geographical origin based on volatiles profiling using SPME-MS and SPME-GC/MS methods.

    Science.gov (United States)

    Ziółkowska, Angelika; Wąsowicz, Erwin; Jeleń, Henryk H

    2016-12-15

    Among methods to detect wine adulteration, profiling volatiles is one with a great potential regarding robustness, analysis time and abundance of information for subsequent data treatment. Volatile fraction fingerprinting by solid-phase microextraction with direct analysis by mass spectrometry without compounds separation (SPME-MS) was used for differentiation of white as well as red wines. The aim was to differentiate between varieties used for wine production and to also differentiate wines by country of origin. The results obtained were compared to SPME-GC/MS analysis in which compounds were resolved by gas chromatography. For both approaches the same type of statistical procedure was used to compare samples: principal component analysis (PCA) followed by linear discriminant analysis (LDA). White wines (38) and red wines (41) representing different grape varieties and various regions of origin were analysed. SPME-MS proved to be advantageous in use due to better discrimination and higher sample throughput. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Identification, characterization and quantification of new impurities by LC-ESI/MS/MS and LC-UV methods in rivastigmine tartrate active pharmaceutical ingredient.

    Science.gov (United States)

    Thomas, Saji; Shandilya, Sanjeev; Bharati, Amber; Paul, Saroj Kumar; Agarwal, Ashutosh; Mathela, Chandra S

    2012-01-05

    Six impurities were detected at trace level in rivastigmine tartrate drug substance by a newly developed high performance liquid chromatography method. Three impurities were characterized rapidly and three impurities were found to be unknown. The unknown impurities were enriched and identified with a combination of semi-preparative HPLC and LC/MS/MS techniques. Proposed structures were further confirmed by characterization using NMR, FT-IR, and EA techniques of impurity standards. Based on the spectroscopic, spectrometric and elemental analysis data unknown impurities were characterized as 3-[1-(dimethylamino)ethyl]phenyl N-ethyl-N-methyl carbamate N-oxide, ethyl-methyl-carbamic acid 4-(1-dimethylamino-ethyl)-phenyl ester and ethyl-methyl-carbamic acid 2-(1-dimethylamino-ethyl)-phenyl ester. A plausible mechanism for the formation of these impurities is also proposed. The method was validated according to ICH guidelines for fourteen impurities to demonstrate specificity, precision, linearity, accuracy and stability indicating nature of the method. Regression analysis showed correlation coefficient value greater than 0.999 for rivastigmine tartrate and its impurities. Accuracy of the method was established based on the recovery obtained between 93.41 and 113.33% for all impurities. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Determination of prodrug treosulfan and its biologically active monoepoxide in rat plasma, liver, lungs, kidneys, muscle, and brain by HPLC-ESI-MS/MS method.

    Science.gov (United States)

    Romański, Michał; Kasprzyk, Anna; Teżyk, Artur; Widerowska, Agnieszka; Żaba, Czesław; Główka, Franciszek

    2017-06-05

    A prodrug treosulfan (TREO) is currently investigated in clinical trials for conditioning prior to hematopoietic stem cell transplantation. Bioanalysis of TREO and its active derivatives, monoepoxide (S,S-EBDM) and diepoxide, in plasma and urine underlay the pharmacokinetic studies of these compounds but cannot explain an organ pharmacological action or toxicity. Recently, distribution of TREO and S,S-EBDM into brain, cerebrospinal fluid, and aqueous humor of the eye has been investigated in animal models and the obtained results presented clinical relevance. In this paper, a selective and rapid HPLC-ESI-MS/MS method was elaborated and validated for the studies of disposition of TREO and S,S-EBDM in rat plasma, liver, lungs, kidneys, muscle, and brain. The two analytes and codeine, internal standard (IS), were isolated from 50μL of plasma and 100μL of supernatants of the tissues homogenates using ultrafiltration Amicon vials. Chromatographic resolution was accomplished on C18 column with isocratic elution. The limits of quantitation of TREO and S,S-EBDM in the studied matrices ranged from 0.11 to 0.93μM. The HPLC-MS/MS method was adequately precise and accurate within and between runs. The IS-normalized matrix effect differed among the tissues and was the most pronounced in a liver homogenate supernatant (approximately 0.55 for TREO and 0.35 for S,S-EBDM). Stability of the analytes in experimental samples was also established. The validated method for the first time enabled determination of TREO and S,S-EBDM in the six life-important tissues in rats following administration of the prodrug. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. LC-MS/MS Peptide Mapping with Automated Data Processing for Routine Profiling of N-Glycans in Immunoglobulins

    Science.gov (United States)

    Shah, Bhavana; Jiang, Xinzhao Grace; Chen, Louise; Zhang, Zhongqi

    2014-06-01

    Protein N-Glycan analysis is traditionally performed by high pH anion exchange chromatography (HPAEC), reversed phase liquid chromatography (RPLC), or hydrophilic interaction liquid chromatography (HILIC) on fluorescence-labeled glycans enzymatically released from the glycoprotein. These methods require time-consuming sample preparations and do not provide site-specific glycosylation information. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) peptide mapping is frequently used for protein structural characterization and, as a bonus, can potentially provide glycan profile on each individual glycosylation site. In this work, a recently developed glycopeptide fragmentation model was used for automated identification, based on their MS/MS, of N-glycopeptides from proteolytic digestion of monoclonal antibodies (mAbs). Experimental conditions were optimized to achieve accurate profiling of glycoforms. Glycan profiles obtained from LC-MS/MS peptide mapping were compared with those obtained from HPAEC, RPLC, and HILIC analyses of released glycans for several mAb molecules. Accuracy, reproducibility, and linearity of the LC-MS/MS peptide mapping method for glycan profiling were evaluated. The LC-MS/MS peptide mapping method with fully automated data analysis requires less sample preparation, provides site-specific information, and may serve as an alternative method for routine profiling of N-glycans on immunoglobulins as well as other glycoproteins with simple N-glycans.

  15. A multi-matrix HILIC-MS/MS method for the quantitation of endogenous small molecule neurological biomarker N-acetyl aspartic acid (NAA).

    Science.gov (United States)

    Sangaraju, Dewakar; Shahidi-Latham, Sheerin K; Burgess, Braydon L; Dean, Brian; Ding, Xiao

    2017-06-05

    A multi-matrix hydrophilic interaction liquid chromatography tandem mass spectrometric method (HILIC-MS/MS) was developed for the quantitation of N-Acetyl Aspartic acid (NAA) using stable isotope labeled internal standard, D3-NAA in various biological matrices such as human plasma, human CSF, mouse plasma, brain and spinal cord. A high throughput 96-well plate format supported liquid extraction (SLE) procedure was developed and used for sample preparation. Mass spectrometric analysis of NAA was performed using selected reaction monitoring transitions in positive electrospray ionization mode. As NAA is endogenously present, a surrogate matrix approach was used for quantitation of NAA and the method was qualified over linear calibration curve range of 0.01-10μg/mL. Intra and inter assay precision indicated by percent relative standard deviation (%RSD) was less than 7.1% for low, medium, medium high and high QCs. The accuracy of the method ranged from 92.6-107.0% of nominal concentration for within-run and between-run for the same QCs. Extraction recovery of NAA and D3-NAA was greater than 76%. Stability of NAA was established in the above biological matrices under bench top (RT, 5h), freeze thaw (-20±10°C, 3 cycles) and moues/human plasma sample collection (Wet ice, RT) conditions. HILIC-MS/MS method was then used to quantify and compare the NAA levels in human plasma and CSF of ALS patients versus control human subjects. NAA CSF levels in control human subjects (73.3±31.0ng/mL,N=10) were found to be slightly higher than ALS patients (46.1±22.6ng/mL, N=10) (P=0.04). No differences were observed in NAA plasma levels in human control subjects (49.7±13.8ng/mL,N=9) as compared to ALS patients (49.6±8.1ng/mL, N=10) (P=0.983). NAA endogenous concentrations in mouse plasma, brain and spinal cord were found to be 243.8±56.8ng/mL (N=6), 1029.8±115.2μg/g tissue weight (N=5) and 487.6±178.4μg/g tissue weight (N=5) respectively. Copyright © 2017 Elsevier B.V. All

  16. The development and validation of an UHPLC-MS/MS method for the rapid quantification of the antiretroviral agent dapivirine in human plasma.

    Science.gov (United States)

    Seserko, Lauren A; Emory, Joshua F; Hendrix, Craig W; Marzinke, Mark A

    2013-11-01

    Dapivirine is a non-nucleoside reverse transcriptase inhibitor designed to prevent HIV-1 viral replication and subsequent propagation. A sensitive method is required to quantify plasma concentrations to assess drug efficacy. Dapivirine-spiked plasma was combined with acetonitrile containing deuterated IS and was processed for analysis. The method has an analytical measuring range from 20 to 10,000 pg/ml. For the LLOQ, low, mid and high QCs, intra- and inter-assay precision (%CV) ranged from 5.58 to 13.89% and 5.23 to 13.36%, respectively, and intra- and inter-day accuracy (% deviation) ranged from -5.61 to 0.75% and -4.30 to 6.24%, respectively. A robust and sensitive LC-MS/MS assay for the high-throughput quantification of the antiretroviral drug dapivirine in human plasma was developed and validated following bioanalytical validation guidelines. The assay meets criteria for the analysis of samples from large research trials.

  17. NMR and MS Methods for Metabolomics.

    Science.gov (United States)

    Amberg, Alexander; Riefke, Björn; Schlotterbeck, Götz; Ross, Alfred; Senn, Hans; Dieterle, Frank; Keck, Matthias

    2017-01-01

    Metabolomics, also often referred as "metabolic profiling," is the systematic profiling of metabolites in biofluids or tissues of organisms and their temporal changes. In the last decade, metabolomics has become more and more popular in drug development, molecular medicine, and other biotechnology fields, since it profiles directly the phenotype and changes thereof in contrast to other "-omics" technologies. The increasing popularity of metabolomics has been possible only due to the enormous development in the technology and bioinformatics fields. In particular, the analytical technologies supporting metabolomics, i.e., NMR, UPLC-MS, and GC-MS, have evolved into sensitive and highly reproducible platforms allowing the determination of hundreds of metabolites in parallel. This chapter describes the best practices of metabolomics as seen today. All important steps of metabolic profiling in drug development and molecular medicine are described in great detail, starting from sample preparation to determining the measurement details of all analytical platforms, and finally to discussing the corresponding specific steps of data analysis.

  18. Development and validation of an UHPLC-MS/MS method for β2-agonists quantification in human urine and application to clinical samples.

    Science.gov (United States)

    Bozzolino, Cristina; Leporati, Marta; Gani, Federica; Ferrero, Cinzia; Vincenti, Marco

    2018-02-20

    A fast analytical method for the simultaneous detection of 24 β 2 -agonists in human urine was developed and validated. The method covers the therapeutic drugs most commonly administered, but also potentially abused β 2 -agonists. The procedure is based on enzymatic deconjugation with β-glucuronidase followed by SPE clean up using mixed-phase cartridges with both ion-exchange and lipophilic properties. Instrumental analysis conducted by UHPLC-MS/MS allowed high peak resolution and rapid chromatographic separation, with reduced time and costs. The method was fully validated according ISO 17025:2005 principles. The following parameters were determined for each analyte: specificity, selectivity, linearity, limit of detection, limit of quantification, precision, accuracy, matrix effect, recovery and carry-over. The method was tested on real samples obtained from patients subjected to clinical treatment under chronic or acute therapy with either formoterol, indacaterol, salbutamol, or salmeterol. The drugs were administered using pressurized metered dose inhalers. All β 2 -agonists administered to the patients were detected in the real samples. The method proved adequate to accurately measure the concentration of these analytes in the real samples. The observed analytical data are discussed with reference to the administered dose and the duration of the therapy. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Development and validation of a sensitive UHPLC-MS/MS method for the simultaneous analysis of tramadol, dextromethorphan chlorpheniramine and their major metabolites in human plasma in forensic context: application to pharmacokinetics.

    Science.gov (United States)

    Heneedak, Hala M; Salama, Ismail; Mostafa, Samia; El-Kady, Ehab; El-Sadek, Mohamed

    2015-07-01

    The prerequisites for forensic confirmatory analysis by LC/MS/MS with respect to European Union guidelines are chromatographic separation, a minimum number of two MS/MS transitions to obtain the required identification points and predefined thresholds for the variability of the relative intensities of the MS/MS transitions (MRM transitions) in samples and reference standards. In the present study, a fast, sensitive and robust method to quantify tramadol, chlorpheniramine, dextromethorphan and their major metabolites, O-desmethyltramadol, dsmethyl-chlorpheniramine and dextrophan, respectively, in human plasma using ibuprofen as internal standard (IS) is described. The analytes and the IS were extracted from plasma by a liquid-liquid extraction method using ethyl acetate-diethyl-ether (1:1). Extracted samples were analyzed by ultra-high-performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry (UHPLC-ESI-MS/MS). Chromatographic separation was performed by pumping the mobile phase containing acetonitrile, water and formic acid (89.2:11.7:0.1) for 2.0 min at a flow rate of 0.25 μL/min into a Hypersil-Gold C18 column, 20 × 2.0 mm (1.9 µm) from Thermoscientific, New York, USA. The calibration curve was linear for the six analytes. The intraday precision (RSD) and accuracy (RE) of the method were 3-9.8 and -1.7-4.5%, respectively. The analytical procedure herein described was used to assess the pharmacokinetics of the analytes in 24 healthy volunteers after a single oral dose containing 50 mg of tramadol hydrochloride, 3 mg chlorpheniramine maleate and 15 mg of dextromethorphan hydrobromide. Copyright © 2014 John Wiley & Sons, Ltd.

  20. Profiles of Steroid Hormones in Canine X-Linked Muscular Dystrophy via Stable Isotope Dilution LC-MS/MS.

    Directory of Open Access Journals (Sweden)

    Helio A Martins-Júnior

    Full Text Available Golden retriever muscular dystrophy (GRMD provides the best animal model for characterizing the disease progress of the human disorder, Duchenne muscular dystrophy (DMD. The purpose of this study was to determine steroid hormone concentration profiles in healthy golden retriever dogs (control group - CtGR versus GRMD-gene carrier (CaGR and affected female dogs (AfCR. Therefore, a sensitive and specific analytical method was developed and validated to determine the estradiol, progesterone, cortisol, and testosterone levels in the canine serum by isotope dilution liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS. To more accurately understand the dynamic nature of the serum steroid profile, the fluctuating levels of these four steroid hormones over the estrous cycle were compared across the three experimental groups using a multivariate statistical analysis. The concentration profiles of estradiol, cortisol, progesterone, and testosterone revealed a characteristic pattern for each studied group at each specific estrous phase. Additionally, several important changes in the serum concentrations of cortisol and estradiol in the CaGR and AfCR groups seem to be correlated with the status and progression of the muscular dystrophy. A comprehensive and quantitative monitoring of steroid profiles throughout the estrous cycle of normal and GRMD dogs were achieved. Significant differences in these profiles were observed between GRMD and healthy animals, most notably for estradiol. These findings contribute to a better understanding of both dog reproduction and the muscular dystrophy pathology. Our data open new venues for hormonal behavior studies in dystrophinopathies and that may affect the quality of life of DMD patients.

  1. X-ray microprobe analysis of platelets. Principles, methods and review of the literature.

    Science.gov (United States)

    Yarom, R

    1983-01-01

    Platelets are well suited to X-ray microanalysis as there is no need for chemical fixation or sectioning, and the concentrations of calcium and phosphorus are above 10(-3). The principles of the technique, the methods of specimen preparation, instrumental conditions during analysis and ways of quantitation are described. This is followed by a review of published reports and a brief summary of the author's own work in the field.

  2. Development of a rapid and sensitive LC-ESI/MS/MS assay for the quantification of propofol using a simple off-line dansyl chloride derivatization reaction to enhance signal intensity.

    Science.gov (United States)

    Beaudry, Francis; Guénette, Sarah Annie; Winterborn, Andrew; Marier, Jean-Francois; Vachon, Pascal

    2005-09-15

    A rapid, selective and sensitive method was developed for the determination of propofol concentration using an off-line dansyl chloride derivatization step to enhance signal intensity. The method consisted of a protein precipitation extraction followed by derivatization with dansyl chloride and analysis by liquid chromatography ionspray tandem mass spectrometry (LC-ESI/MS/MS). The separation was achieved using a 100 mm x 2 mm C8 analytical column combined with an isocratic mobile phase composed of 80:20 acetonitrile: 0.5% formic acid in water. Signal intensity of the propofol-dansyl chloride derivative was increased up to 200-fold as compared to the underivatized propofol in positive electrospray mode. An analytical range of 20-20,000 ng/mL was used in the calibration curve of plasma and blood samples. The novel method met all requirements of specificity, sensitivity, linearity, precision, accuracy and stability. A pharmacokinetic study was performed in rats and the novel analytical method was used as a routine analysis to provide enhanced measurements of plasma and blood concentrations of propofol. Blood and plasma pharmacokinetic results show that a very important fraction of propofol distributes into red blood cells. In conclusion, a rapid and sensitive LC-ESI/MS/MS method using a derivatization agent was developed to enhance signal intensity of propofol. Routine analysis with the novel method provided accurate results and enhanced the detection levels of plasma and blood concentrations of propofol to better characterize the in vivo biodisposition of propofol.

  3. Determination of residues of three triphenylmethane dyes and their metabolites (malachite green, leuco malachite green, crystal violet, leuco crystal violet, and brilliant green) in aquaculture products by LC/MS/MS: first action 2012.25.

    Science.gov (United States)

    Hurtaud-Pessel, Dominique; Couëdor, Pierrick; Verdon, Eric; Dowell, Dawn

    2013-01-01

    During the AOAC Annual Meeting held from September 30 to October 3, 2012 in Las Vegas, NV, the Expert Review Panel (ERP) on Veterinary Drug Residues reviewed data for the method for determination of residues of three triphenylmethane dyes and their metabolites (malachite green, leuco malachite green, crystal violet, leuco crystal violet, and brilliant green) in aquaculture products by LC/MS/MS, previously published in the Journal of Chromatography A 1218, 1632-1645 (2006). The method data were reviewed and compared to the standard method performance requirements (SMPRs) found in SMPR 2009.001, published in AOAC's Official Methods of Analysis, 19th Ed. (2012). The ERP determined that the data were acceptable, and the method was approved AOAC Official First Action. The method uses acetonitrile to isolate the analyte from the matrix. Then determination is conducted by LCIMS/MS with positive electrospray ionization. Accuracy ranged from 100.1 to 109.8% for samples fortified at levels of 0.5, 0.75, 1.0, and 2.0 microg/kg. Precision ranged from 2.0 to 10.3% RSD for the intraday samples and 1.9 to 10.6% for the interday samples analyzed over 3 days. The described method is designed to accurately operate in the analytical range from 0.5 to 2 microg/kg, where the minimum required performance limit for laboratories has been fixed in the European Union at 2.0 microg/kg for these banned substances and their metabolites. Upper levels of concentrations (1-100 microg/kg) can be analyzed depending on the different optional calibrations used.

  4. Combined evaluation of personality, risk and coping in MS patients: A step towards individualized treatment choice - The PeRiCoMS-Study I.

    Science.gov (United States)

    Bsteh, G; Monz, E; Zamarian, L; Hagspiel, S; Hegen, H; Auer, M; Wurth, S; Di Pauli, F; Deisenhammer, F; Berger, T

    2017-05-15

    Multiple sclerosis (MS) is a chronic inflammatory neurological disease requiring disease-modifying treatment (DMT). To provide patients with the optimal individual therapeutic option, treatment recommendations should be based not only on individual disease course and DMT specific benefit-risk estimates, but also on patient's individual characteristics such as personality, risk attitude and coping strategies. However, these characteristics are difficult to objectify in clinical routine practice without the support of appropriate evaluation instruments. To identify and to assemble an objective test battery measuring personality, risk attitude and coping strategies in MS patients. A comprehensive literature search was performed to obtain all questionnaires assessing personality, risk attitude and coping strategies. Availability in German language, validation in a published normative collective and a reliability of >0.70 were required for our purposes. Based on these criteria, we chose the Big-Five-Personality Test, UPPS Impulsive Behaviour Scale, Domain-Specific Risk-Taking scale (DOSPERT), Brief-COPE and Stress & Coping Inventory (SCI). Results were compared to published normative controls of the respective questionnaires. Out of 22 MS patients (7 males, 15 females) participating in this study, 19 (86.4%) completed all questionnaires. The median completion time was 45min (min-max range: 25-60min). The median scores of the MS group were within the average range of published control samples in all questionnaires. We report that traits of personality, risk attitude and coping strategies can be effectively and feasibly tested in MS patients by the instruments used in our exploratory study. There were no differences between MS patients and healthy controls, thus enabling assessment without being influenced by the diagnosis of MS. After validation in a larger cohort the "PeRiCoMS"-battery will be useful as another step towards a more individualized shared

  5. A new high-throughput LC-MS method for the analysis of complex fructan mixtures

    DEFF Research Database (Denmark)

    Verspreet, Joran; Hansen, Anders Holmgaard; Dornez, Emmie

    2014-01-01

    In this paper, a new liquid chromatography-mass spectrometry (LC-MS) method for the analysis of complex fructan mixtures is presented. In this method, columns with a trifunctional C18 alkyl stationary phase (T3) were used and their performance compared with that of a porous graphitized carbon (PGC...

  6. Simultaneous Determination of Cyclosporine A, Tacrolimus, Sirolimus, and Everolimus in Whole-Blood Samples by LC-MS/MS

    Directory of Open Access Journals (Sweden)

    Mustafa Karapirli

    2012-01-01

    Full Text Available Objectives. Cyclosporine A (CyA, tacrolimus (TRL, sirolimus (SIR, and everolimus (RAD are immunosuppressive drugs frequently used in organ transplantation. Our aim was to confirm a robust sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS method for determination of CyA, TRL, SIR, and RAD in whole-blood samples. Materials and Methods. We used an integrated online solid-phase extraction-LC-MS/MS system and atmospheric pressure ionization tandem mass spectrometry (API-MS/MS in the multiple reaction monitoring (MRM detection mode. CyA, TRL, SIR, and RAD were simultaneously analyzed in whole blood treated with precipitation reagent taken from transplant patients. Results. System performance parameters were suitable for using this method as a high-throughput technique in clinical practice. The high concentration of one analyte in the sample did not affect the concentration of other analytes. Total analytical time was 2.5 min, and retention times of all analytes were shorter than 2 minutes. Conclusion. This LC-MS/MS method can be preferable for therapeutic drug monitoring of these immunosuppressive drugs (CyA, TRL, SRL, and RAD in whole blood. Sample preparation was too short and simple in this method, and it permits robust, rapid, sensitive, selective, and simultaneous determination of these drugs.

  7. Development of a novel solid-phase extraction, LC-MS/MS method for the analysis of ethyl carbamate in alcoholic beverages: application to South African wine and spirits.

    Science.gov (United States)

    Alberts, Philippus; Stander, Maria A; De Villiers, André

    2011-01-01

    Ethyl carbamate (EC) is a known genotoxic carcinogen that is frequently present in alcoholic beverages and is therefore a public health concern. As a consequence, maximum concentration levels for EC in these commodities are legislated in several countries. Quantitative analytical methods are therefore essential to monitor EC levels in beverages. Most published analytical methods for the determination of EC in alcoholic beverages utilise elaborate sample pre-treatment procedures to obtain injectable samples, or yield low sensitivity, for example where direct injection is used. In addition, these procedures often require large volumes of toxic solvents and are not generally applicable to diverse alcoholic beverages. This paper describes a novel procedure for the determination of EC in wines, fortified wines and spirits. The procedure is based on reversed-phase solid-phase extraction (SPE) sample clean-up combined with normal-phase liquid chromatography-atmospheric pressure chemical ionisation tandem mass spectrometric (NP-LC-APCI-MS/MS) analysis. This method provides a rapid, robust and simple analytical procedure suitable for the analysis of a diverse range of alcoholic beverages. The accuracy of the method (expressed as average recovery from diverse matrices) is 94.5%, with limits of detection (LODs) ranging between 0.25 and 0.63 µg l(-1) for different matrices. Benefits such as simplified sample preparation, low detection limits, low solvent consumption and good selectivity render the methodology ideally suited to study the occurrence of EC in diverse commodities. The method was applied to study the occurrence of EC in South African wines, fortified wines and spirits. South African wines, aged 1-9 years, contained 1.8-31 µg l(-1) EC (RSD = 69%, n = 106), fortified wines aged 2-34 years contained 2.8-79 µg l(-1) EC (RSD = 89%, n = 21), and brandies aged 3-20 years contained 4.4-95 µg l(-1) EC (RSD = 105%, n = 26). Factors

  8. Tokamak physics studies using x-ray diagnostic methods

    International Nuclear Information System (INIS)

    Hill, K.W.; Bitter, M.; von Goeler, S.

    1987-03-01

    X-ray diagnostic measurements have been used in a number of experiments to improve our understanding of important tokamak physics issues. The impurity content in TFTR plasmas, its sources and control have been clarified through soft x-ray pulse-height analysis (PHA) measurements. The dependence of intrinsic impurity concentrations and Z/sub eff/ on electron density, plasma current, limiter material and conditioning, and neutral-beam power have shown that the limiter is an important source of metal impurities. Neoclassical-like impurity peaking following hydrogen pellet injection into Alcator C and a strong effect of impurities on sawtooth behavior were demonstrated by x-ray imaging (XIS) measurements. Rapid inward motion of impurities and continuation of m = 1 activity following an internal disruption were demonstrated with XIS measurements on PLT using injected aluminum to enhance the signals. Ion temperatures up to 12 keV and a toroidal plasma rotation velocity up to 6 x 10 5 m/s have been measured by an x-ray crystal spectrometer (XCS) with up to 13 MW of 85-keV neutral-beam injection in TFTR. Precise wavelengths and relative intensities of x-ray lines in several helium-like ions and neon-like ions of silver have been measured in TFTR and PLT by the XCS. The data help to identify the important excitation processes predicted in atomic physics. Wavelengths of n = 3 to 2 silver lines of interest for x-ray lasers were measured, and precise instrument calibration techniques were developed. Electron thermal conductivity and sawtooth dynamics have been studied through XIS measurements on TFTR of heat-pulse propagation and compound sawteeth. A non-Maxwellian electron distribution function has been measured, and evidence of the Parail-Pogutse instability identified by hard x-ray PHA measurements on PLT during lower-hybrid current-drive experiments

  9. Development and single-laboratory validation of a UHPLC-MS/MS method for quantitation of microcystins and nodularin in natural water, cyanobacteria, shellfish and algal supplement tablet powders.

    Science.gov (United States)

    Turner, Andrew D; Waack, Julia; Lewis, Adam; Edwards, Christine; Lawton, Linda

    2018-02-01

    A simple, rapid UHPLC-MS/MS method has been developed and optimised for the quantitation of microcystins and nodularin in wide variety of sample matrices. Microcystin analogues targeted were MC-LR, MC-RR, MC-LA, MC-LY, MC-LF, LC-LW, MC-YR, MC-WR, [Asp3] MC-LR, [Dha7] MC-LR, MC-HilR and MC-HtyR. Optimisation studies were conducted to develop a simple, quick and efficient extraction protocol without the need for complex pre-analysis concentration procedures, together with a rapid sub 5min chromatographic separation of toxins in shellfish and algal supplement tablet powders, as well as water and cyanobacterial bloom samples. Validation studies were undertaken on each matrix-analyte combination to the full method performance characteristics following international guidelines. The method was found to be specific and linear over the full calibration range. Method sensitivity in terms of limits of detection, quantitation and reporting were found to be significantly improved in comparison to LC-UV methods and applicable to the analysis of each of the four matrices. Overall, acceptable recoveries were determined for each of the matrices studied, with associated precision and within-laboratory reproducibility well within expected guidance limits. Results from the formalised ruggedness analysis of all available cyanotoxins, showed that the method was robust for all parameters investigated. The results presented here show that the optimised LC-MS/MS method for cyanotoxins is fit for the purpose of detection and quantitation of a range of microcystins and nodularin in shellfish, algal supplement tablet powder, water and cyanobacteria. The method provides a valuable early warning tool for the rapid, routine extraction and analysis of natural waters, cyanobacterial blooms, algal powders, food supplements and shellfish tissues, enabling monitoring labs to supplement traditional microscopy techniques and report toxicity results within a short timeframe of sample receipt. The new

  10. An UHPLC-MS/MS method for simultaneous quantification of human amyloid beta peptides Aβ1-38, Aβ1-40 and Aβ1-42 in cerebrospinal fluid using micro-elution solid phase extraction.

    Science.gov (United States)

    Lin, Ping-Ping; Chen, Wei-Li; Yuan, Fei; Sheng, Lei; Wu, Yu-Jia; Zhang, Wei-Wei; Li, Guo-Qing; Xu, Hong-Rong; Li, Xue-Ning

    2017-12-01

    Amyloid beta (Aβ) peptides in cerebrospinal fluid are extensively estimated for identification of Alzheimer's disease (AD) as diagnostic biomarkers. Unfortunately, their pervasive application is hampered by interference from Aβ propensity of self-aggregation, nonspecifically bind to surfaces and matrix proteins, and by lack of quantitive standardization. Here we report on an alternative Ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous measurement of human amyloid beta peptides Aβ1-38, Aβ1-40 and Aβ1-42 in cerebrospinal fluid (CSF) using micro-elution solid phase extraction (SPE). Samples were pre-processing by the mixed-mode micro-elution solid phase extraction and quantification was performed in the positive ion multiple reaction monitoring (MRM) mode using electrospray ionization. The stable-isotope labeled Aβ peptides 15 N 51 - Aβ1-38, 15 N 53 - Aβ1-40 and 15 N 55 - Aβ1-42 peptides were used as internal standards. And the artificial cerebrospinal fluid (ACSF) containing 5% rat plasma was used as a surrogate matrix for calibration curves. The quality control (QC) samples at 0.25, 2 and 15ng/mL were prepared. A "linear" regression (1/x 2 weighting): y=ax+b was used to fit the calibration curves over the concentration range of 0.1-20ng/mL for all three peptides. Coefficient of variation (CV) of intra-batch and inter-batch assays were all less than 6.44% for Aβ1-38, 6.75% for Aβ1-40 and 10.74% for Aβ1-42. The precision values for all QC samples of three analytes met the acceptance criteria. Extract recoveries of Aβ1-38, Aβ1-40 and Aβ1-42 were all greater than 70.78%, both in low and high QC samples. The stability assessments showed that QC samples at both low and high levels could be stable for at least 24h at 4°C, 4h at room temperature and through three freeze-thaw cycles without sacrificing accuracy or precision. And no significant carryover effect was observed. This validated UHPLC/MS/MS

  11. A General LC-MS/MS Method for Monitoring Potential β-Lactam Contamination in Drugs and Drug-Manufacturing Surfaces.

    Science.gov (United States)

    Qiu, Chen; Zhu, Hongbin; Ruzicka, Connie; Keire, David; Ye, Hongping

    2018-05-15

    Penicillins and some non-penicillin β-lactams may cause potentially life-threatening allergic reactions. Thus, possible cross contamination of β-lactams in food or drugs can put people at risk. Therefore, when there is a reasonable possibility that a non-penicillin product could be contaminated by penicillin, the drug products are tested for penicillin contamination. Here, a sensitive and rapid method for simultaneous determination of multiple β-lactam antibiotics using high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed and validated. Mass spectral acquisition was performed on a Q-Exactive HF mass spectrometer in positive ion mode with parallel reaction monitoring (PRM). The method was validated for seven β-lactam antibiotics including one or two from each class and a synthetic intermediate. The quantification precision and accuracy at 200 ppb were in the range of ± 1.84 to ± 4.56 and - 5.20 to 3.44%, respectively. The limit of detection (LOD) was 0.2 ppb, and the limit of quantitation (LOQ) was 2 ppb with a linear dynamic range (LDR) of 2-2000 ppb for all eight β-lactams. From various drug products, the recoveries of eight β-lactams at 200 and 2 ppb ranged from 93.8 ± 3.2 to 112.1 ± 4.2% and 89.7 ± 4.6 to 110.6 ± 1.9%, respectively. The application of the method for detecting cross contamination of trace β-lactams (0.2 ppb) and for monitoring facility surface cleaning was also investigated. This sensitive and fast method was fit-for-purpose for detecting and quantifying trace amount of β-lactam contamination, monitoring cross contamination in manufacturing processes, and determining potency for regulatory purposes and for quality control.

  12. An improved method for fast and selective separation of carotenoids by LC-MS.

    Science.gov (United States)

    Abate-Pella, Daniel; Freund, Dana M; Slovin, Janet P; Hegeman, Adrian D; Cohen, Jerry D

    2017-11-01

    Carotenoids are a large class of compounds that are biosynthesized by condensation of isoprene units in plants, fungi, bacteria, and some animals. They are characteristically highly conjugated through double bonds, which lead to many isomers as well susceptibility to oxidation and other chemical modifications. Carotenoids are important because of their potent antioxidant activity and are the pigments responsible for color in a wide variety of foods. Human consumption is correlated to many health benefits including prevention of cancer, cardiovascular disease, and age-related disease. Extreme hydrophobicity, poor stability, and low concentration in biological samples make these compounds difficult to analyze and difficult to develop analytical methods for aimed towards identification and quantification. Examples in the literature frequently report the use of exotic stationary phases, solvents, and additives, such as ethyl acetate, dichloromethane, and methyl tert-butyl ether that are incompatible with liquid chromatography mass spectrometry (LC-MS). In order to address these issues, we implemented the use of LC-MS friendly conditions using a low-hydrophobicity cyano-propyl column (Agilent Zorbax SB-CN). We successfully differentiated between isomeric carotenoids by optimizing two gradient methods and using a mixture of 11 standards and LC-MS in positive ionization mode. Three complex biological samples from strawberry leaf, chicken feed supplement, and the photosynthetic bacterium Chloroflexus aurantiacus were analyzed and several carotenoids were resolved in these diverse backgrounds. Our results show this methodology is a significant improvement over other alternatives for analyzing carotenoids because of its ease of use, rapid analysis time, high selectivity, and, most importantly, its compatibility with typical LC-MS conditions. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. A sensitive HPLC-MS/MS method for the simultaneous detection of microbial transglutaminase, and bovine and porcine fibrinogen/thrombin in restructured meat.

    Science.gov (United States)

    Jira, Wolfgang; Schwägele, Fredi

    2017-12-15

    A sensitive HPLC-MS/MS method for the simultaneous detection of microbial transglutaminase (TG) from Streptomyces mobaraensis, and bovine and porcine fibrinogen/thrombin in restructured meat was developed using tryptic marker peptides of TG (five markers), and bovine and porcine fibrinogen (six markers each). Meat binding experiments with beef and pork were performed using a technical TG mixture (Activa, Ajinomoto), and bovine and porcine plasmapowder FG (PPFG; Sonac B.V.). The method developed allows the simultaneous detection of the use of these cold-set binders in raw and heated samples. The peak areas of the fibrinogen marker peptides were increased by a factor of about 100, compared to blank values originating from the occurrence of residual blood in meat, using a concentration of 0.6% bovine and porcine PPFG. A differentiation between the use of blood plasma powder and PPFG using the ratios of fibrinogen to serotransferrin peptide peak areas seems to be possible. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. The development and validation of an UHPLC–MS/MS method for the rapid quantification of the antiretroviral agent dapivirine in human plasma

    Science.gov (United States)

    Seserko, Lauren A; Emory, Joshua F; Hendrix, Craig W; Marzinke, Mark A

    2014-01-01

    Background Dapivirine is a non-nucleoside reverse transcriptase inhibitor designed to prevent HIV-1 viral replication and subsequent propagation. A sensitive method is required to quantify plasma concentrations to assess drug efficacy. Results Dapivirine-spiked plasma was combined with acetonitrile containing deuterated IS and was processed for analysis. The method has an analytical measuring range from 20 to 10,000 pg/ml. For the LLOQ, low, mid and high QCs, intra- and inter-assay precision (%CV) ranged from 5.58 to 13.89% and 5.23 to 13.36%, respectively, and intra- and inter-day accuracy (% deviation) ranged from -5.61 to 0.75% and -4.30 to 6.24%, respectively. Conclusion A robust and sensitive LC–MS/MS assay for the high-throughput quantification of the antiretroviral drug dapivirine in human plasma was developed and validated following bioanalytical validation guidelines. The assay meets criteria for the analysis of samples from large research trials. PMID:24256358

  15. A Deep Chandra Observation of the Distant Galaxy Cluster MS 1137.5+6625

    Science.gov (United States)

    Grego, Laura; Vrtilek, J. M.; Van Speybroeck, Leon; David, Laurence P.; Forman, William; Carlstrom, John E.; Reese, Erik D.; Joy, Marshall K.

    2004-06-01

    We present results from a deep Chandra observation of MS 1137.5+66, a distant (z=0.783) and massive cluster of galaxies. Only a few similarly massive clusters are currently known at such high redshifts; accordingly, this observation provides much needed information on the dynamical state of these rare systems. The cluster appears both regular and symmetric in the X-ray image. However, our analysis of the spectral and spatial X-ray data in conjunction with interferometric Sunyaev-Zel'dovich effect data and published deep optical imaging suggests that the cluster has a fairly complex structure. The angular diameter distance we calculate from the Chandra and Sunyaev-Zel'dovich effect data assuming an isothermal, spherically symmetric cluster implies a low value for the Hubble constant for which we explore possible explanations.

  16. Development and validation of a UPLC-MS/MS method to monitor cephapirin excretion in dairy cows following intramammary infusion.

    Directory of Open Access Journals (Sweden)

    Partha Ray

    Full Text Available Cephapirin, a cephalosporin antibiotic, is used by the majority of dairy farms in the US. Fecal and urinary excretion of cephapirin could introduce this compound into the environment when manure is land applied as fertilizer, and may cause development of bacterial resistance to antibiotics critical for human health. The environmental loading of cephapirin by the livestock industry remains un-assessed, largely due to a lack of appropriate analytical methods. Therefore, this study aimed to develop and validate a cephapirin quantification method to capture the temporal pattern of cephapirin excretion in dairy cows following intramammary infusion. The method includes an extraction with phosphate buffer and methanol, solid-phase extraction (SPE clean-up, and quantification using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS. The LOQ values of the developed method were 4.02 µg kg(-1 and 0.96 µg L(-1 for feces and urine, respectively. This robust method recovered >60% and >80% cephapirin from spiked blank fecal and urine samples, respectively, with acceptable intra- and inter-day variation (<10%. Using this method, we detected trace amounts (µg kg(-1 of cephapirin in dairy cow feces, and cephapirin in urine was detected at very high concentrations (133 to 480 µg L(-1. Cephapirin was primarily excreted via urine and its urinary excretion was influenced by day (P = 0.03. Peak excretion (2.69 mg was on day 1 following intramammary infusion and decreased sharply thereafter (0.19, 0.19, 0.08, and 0.17 mg on day 2, 3, 4, and 5, respectively reflecting a quadratic pattern of excretion (Quadratic: P = 0.03. The described method for quantification of cephapirin in bovine feces and urine is sensitive, accurate, and robust and allowed to monitor the pattern of cephapirin excretion in dairy cows. This data will help develop manure segregation and treatment methods to minimize the risk of antibiotic loading to the environment from

  17. Apparatus and method X-ray image processing

    International Nuclear Information System (INIS)

    1984-01-01

    The invention relates to a method for X-ray image processing. The radiation passed through the object is transformed into an electric image signal from which the logarithmic value is determined and displayed by a display device. Its main objective is to provide a method and apparatus that renders X-ray images or X-ray subtraction images with strong reduction of stray radiation. (Auth.)

  18. An Electronic Publishing Model for Academic Publishers.

    Science.gov (United States)

    Gold, Jon D.

    1994-01-01

    Describes an electronic publishing model based on Standard Generalized Markup Language (SGML) and considers its use by an academic publisher. Highlights include how SGML is used to produce an electronic book, hypertext, methods of delivery, intellectual property rights, and future possibilities. Sample documents are included. (two references) (LRW)

  19. Comparison of high sensitivity analytical methods (PTR-MS, MIMS, GC-O, SA) and application to food chemistry

    International Nuclear Information System (INIS)

    Boscaini, E.

    2002-10-01

    Application of PTR-MS to flavor analysis and the development of the membrane introduction proton-transfer-reaction-mass-spectrometry are the main topics of this thesis. The results of classical sensory analysis and of PTR-MS analysis are compared in defining flavor profiles of 7 different brands of mozzarella cheese. The PTR-MS mass spectra of the headspace of mozzarella held at 36 o C are compared to the judge panel flavor profile. Multivariate statistical data analysis shows that the two methods perform comparable sample discrimination. This shows that PTR-MS is a very promising method for the instrumental evaluation of the flavour sensory profile of food, opening new opportunities both in the control of quality and technological processes, as well as in the fundamental comprehension of the physiological processes of aroma perception. In the same chapter is also described a method for the identification of the masses of a mass spectra obtained with PTR-MS. Although the identification is always tentative, it might suggest which substances play an important role in the classification of different products. I.e. mass 45 and 47 associated to acetaldehyde and ethanol respectively reveal a higher fermentation activity in product B than G, as expected due to their manufacture processes. Gas Chromatography-Olfactometry (GC-O) and Proton Transfer Reaction-Mass Spectrometry (PTR-MS) techniques were used to define odor active and volatile profile of three grana cheeses: Grana Padano (GP), Parmigiano Reggiano (PR) and Grana Trentino (GT). Samples for GC-O analysis were prepared by dynamic headspace extraction while a direct analysis of the headspace formed over cheese was performed by PTR-MS. Major contribution to the odor profile was given by ethyl butanoate, 2-heptanone and ethyl hexanoate with fruity notes. High concentration of mass 45 tentatively identified with acetaldehyde was found by PTR-MS analysis. Low odor threshold compounds e.g. methional and 1-octen-3-one

  20. Data-independent MS/MS quantification of neuropeptides for determination of putative feeding-related neurohormones in microdialysate.

    Science.gov (United States)

    Schmerberg, Claire M; Liang, Zhidan; Li, Lingjun

    2015-01-21

    Food consumption is an important behavior that is regulated by an intricate array of neuropeptides (NPs). Although many feeding-related NPs have been identified in mammals, precise mechanisms are unclear and difficult to study in mammals, as current methods are not highly multiplexed and require extensive a priori knowledge about analytes. New advances in data-independent acquisition (DIA) MS/MS and the open-source quantification software Skyline have opened up the possibility to identify hundreds of compounds and quantify them from a single DIA MS/MS run. An untargeted DIA MS(E) quantification method using Skyline software for multiplexed, discovery-driven quantification was developed and found to produce linear calibration curves for peptides at physiologically relevant concentrations using a protein digest as internal standard. By using this method, preliminary relative quantification of the crab Cancer borealis neuropeptidome (winnowing candidate NPs related to a behavior of interest in a functionally relevant manner, and demonstrates the success of such a UPLC-MS(E) quantification method using the open source software Skyline.

  1. A fit-for-purpose LC-MS/MS method for the simultaneous quantitation of ATP and 2,3-DPG in human K2EDTA whole blood.

    Science.gov (United States)

    Kim, Hyeryun; Kosinski, Penelope; Kung, Charles; Dang, Lenny; Chen, Yue; Yang, Hua; Chen, Yuan-Shek; Kramer, Jordyn; Liu, Guowen

    2017-09-01

    Many hemolytic anemias results in major metabolic abnormalities: two common metabolite abnormalities include increased levels of 2,3-diphosphoglycerate (2,3-DPG) and decreased levels of adenosine triphosphate (ATP). To better monitor the concentration changes of these metabolites, the development of a reliable LC-MS/MS method to quantitatively profile the concentrations of 2, 3-DPG and ATP in whole blood is essential to understand the effects of investigational therapeutics. Accurate quantification of both compounds imposes great challenges to bioanalytical scientists due to their polar, ionic and endogenous nature. Here we present an LC-MS/MS method for the reliable quantification of 2,3-DPG and ATP from K 2 EDTA human whole blood (WB) simultaneously. Whole blood samples were spiked with stable isotope labeled internal standards, processed by protein precipitation extraction, and analyzed using zwitterionic ion chromatography-hydrophilic interaction chromatography (ZIC-HILIC) coupled with tandem mass spectrometry. The linear analytical range of the assay was 50-3000μg/mL. The fit-for-purpose method demonstrated excellent accuracy and precision. The overall accuracy was within ±10.5% (%RE) for both analytes and the intra- and inter-assay precision (%CV) were less than 6.7% and 6.2% for both analytes, respectively. ATP and 2,3-DPG were found to be stable in human K 2 EDTA blood for at least 8h at 4°C, 96days when stored at -70°C and after three freeze/thaw cycles. The assay has been successfully applied to K 2 EDTA human whole blood samples to support clinical studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. EPA CRL MS014: Analysis of Aldicarb, Bromadiolone, Carbofuran, Oxamyl and Methomyl in Water by Multiple Reaction Monitoring Liquid Chromatography / Tandem Mass Spectrometry (LC/MS/MS)

    Science.gov (United States)

    Method MS014 describes procedures for solvent extraction of aldicarb, bromadiolone, carbofuran, oxamyl and methomyl from water samples, followed by analysis using liquid chromatography tandem mass spectrometry (LC-MS-MS).

  3. A sample preparation method for recovering suppressed analyte ions in MALDI TOF MS

    NARCIS (Netherlands)

    Lou, X.; Waal, de B.F.M.; Milroy, L.G.; Dongen, van J.L.J.

    2015-01-01

    In matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI TOF MS), analyte signals can be substantially suppressed by other compounds in the sample. In this technical note, we describe a modified thin-layer sample preparation method that significantly reduces the analyte

  4. Chemometrically assisted development and validation of LC-MS/MS method for the analysis of potential genotoxic impurities in meropenem active pharmaceutical ingredient.

    Science.gov (United States)

    Grigori, Katerina; Loukas, Yannis L; Malenović, Anđelija; Samara, Vicky; Kalaskani, Anastasia; Dimovasili, Efi; Kalovidouri, Magda; Dotsikas, Yannis

    2017-10-25

    A sensitive Liquid Chromatography tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantitative analysis of three potential genotoxic impurities (318BP, M9, S5) in meropenem Active Pharmaceutical Ingredient (API). Due to the requirement for LOD values in ppb range, a high concentration of meropenem API (30mg/mL) had to be injected. Therefore, efficient determination of meropenem from its impurities became a critical aim of this study, in order to divert meropenem to waste, via a switching valve. ‎ After the selection of the important factors affecting analytes' elution, a Box-Behnken design was utilized to set the plan of experiments conducted with UV detector. As responses, the separation factor s between the last eluting impurity and meropenem, as well as meropenem retention factor k were used. Grid point search methodology was implemented aiming to obtain the optimal conditions that simultaneously comply to the conflicted criteria. Optimal mobile phase consisted of ACN, methanol and 0.09% HCOOH at a ratio 71/3.5/15.5v/v. All impurities and internal standard omeprazole were eluted before 7.5min and at 8.0min the eluents were directed to waste. The protocol was transferred to LC-MS/MS and validated according to ICH guidelines. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Novel X-ray Communication Based XNAV Augmentation Method Using X-ray Detectors

    Directory of Open Access Journals (Sweden)

    Shibin Song

    2015-09-01

    Full Text Available The further development of X-ray pulsar-based NAVigation (XNAV is hindered by its lack of accuracy, so accuracy improvement has become a critical issue for XNAV. In this paper, an XNAV augmentation method which utilizes both pulsar observation and X-ray ranging observation for navigation filtering is proposed to deal with this issue. As a newly emerged concept, X-ray communication (XCOM shows great potential in space exploration. X-ray ranging, derived from XCOM, could achieve high accuracy in range measurement, which could provide accurate information for XNAV. For the proposed method, the measurement models of pulsar observation and range measurement observation are established, and a Kalman filtering algorithm based on the observations and orbit dynamics is proposed to estimate the position and velocity of a spacecraft. A performance comparison of the proposed method with the traditional pulsar observation method is conducted by numerical experiments. Besides, the parameters that influence the performance of the proposed method, such as the pulsar observation time, the SNR of the ranging signal, etc., are analyzed and evaluated by numerical experiments.

  6. Development and validation of an LC-MS/MS method for the quantification of tiamulin, trimethoprim, tylosin, sulfadiazine and sulfamethazine in medicated feed.

    Science.gov (United States)

    Patyra, Ewelina; Nebot, Carolina; Gavilán, Rosa Elvira; Cepeda, Alberto; Kwiatek, Krzysztof

    2018-01-22

    A new multi-compound method for the analysis of veterinary drugs, namely tiamulin, trimethoprim, tylosin, sulfadiazine and sulfamethazine was developed and validated in medicated feeds. After extraction, the samples were centrifuged, diluted in Milli-Q water, filtered and analysed by high performance liquid chromatography coupled to tandem mass spectrometry. The separation of the analytes was performed on a biphenyl column with a gradient of 0.1% formic acid in acetonitrile and 0.1% formic acid in Milli-Q water. Quantitative validation was done in accordance with the guidelines laid down in European Commission Decision 2002/657/EC. Method performances were evaluated by the following parameters: linearity (R 2  tiamulin, tylosin and sulfamethazine were detected at the concentration levels declared by the manufacturers. The developed method can therefore be successfully used to routinely control the content and homogeneity of these antibacterial substances in medicated feed. Abbreviations AAFCO - Association of American Feed Control Officials; TYL - tylosin; TIAM - tiamulin fumarate; TRIM - trimethoprim; SDZ - sulfadiazine; SMZ - sulfamethazine; UV - ultraviolet detector; FLD - fluorescence detector; HPLC - high performance liquid chromatography; MS/MS - tandem mass spectrometry; LOD - limit of detection; LOQ - limit of quantification; CV - coefficient of variation; SD - standard deviation; U - uncertainty.

  7. Publishing studies: being part of a cultural practice plus x ?

    Directory of Open Access Journals (Sweden)

    Christoph Bläsi

    2015-07-01

    Full Text Available In some parts of the world, Publishing Studies are a fairly well-established field of research as well as of higher education. Not least since this is not so much the case in continental Europe, the Publishing Studies community increasingly sees a more elaborated self-concept as an important prerequisite for a prosperous further development of the field in research as well as in teaching. This paper starts off by relating the question for an advanced self-concept of Publishing Studies to the question what criteria have to be fulfilled to call a field (like Publishing Studies a scholarly discipline. As the second source for the possible formation of a more elaborate self-concept, the paper presents the first results of an ongoing empirical research project. In this projects, extensive expert interviews with representatives of UK Publishing Studies study programs and research institutions are evaluated to shed light on the core questions related to Publishing Studies as a discipline / „discipline“ in a bottom-up manner. After presenting a very clear and differentiated North American view as an additional point of reference, a contribution to the discussion on Publishing Studies is proposed.

  8. Determination of 48 fragrance allergens in toys using GC with ion trap MS/MS.

    Science.gov (United States)

    Lv, Qing; Zhang, Qing; Li, Wentao; Li, Haiyu; Li, Pi; Ma, Qiang; Meng, Xianshuang; Qi, Meiling; Bai, Hua

    2013-11-01

    This paper presents a method for the simultaneous determination of 48 fragrance allergens in four types of toys (plastic toys, play clays, plush toys, and paper toys) based on GC with ion trap MS/MS. Compared with single-stage MS, MS/MS is superior in terms of the qualification and quantification of a large range of compounds in complicated matrices. Procedures for extraction and purification were optimized for each toy type. The method proved to be linear over a wide range of concentrations for all analytes with correlation coefficients between 0.9768 and 0.9999. Validation parameters, namely, LODs and LOQs, ranged from 0.005-5.0 and from 0.02-20 mg/kg, respectively. Average recoveries of target compounds (spiked at three concentration levels) were in the range of 79.5-109.1%. Intraday and interday repeatabilities of the proposed method varied from 0.7-10.5% and from 3.1-13.4%, respectively. The proposed method was used to monitor fragrance allergens in commercial toy products. Our findings indicate that this method is an accurate and effective technique for analyzing fragrance allergens in materials composed of complex components. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. A reliable and validated LC-MS/MS method for the simultaneous quantification of 4 cannabinoids in 40 consumer products.

    Science.gov (United States)

    Meng, Qingfang; Buchanan, Beth; Zuccolo, Jonathan; Poulin, Mathieu-Marc; Gabriele, Joseph; Baranowski, David Charles

    2018-01-01

    In the past 50 years, Cannabis sativa (C. sativa) has gone from a substance essentially prohibited worldwide to one that is gaining acceptance both culturally and legally in many countries for medicinal and recreational use. As additional jurisdictions legalize Cannabis products and the variety and complexity of these products surpass the classical dried plant material, appropriate methods for measuring the biologically active constituents is paramount to ensure safety and regulatory compliance. While there are numerous active compounds in C. sativa the primary cannabinoids of regulatory and safety concern are (-)-Δ⁹-tetrahydrocannabinol (THC), cannabidiol (CBD), and their respective acidic forms THCA-A and CBDA. Using the US Food and Drug Administration (FDA) bioanalytical method validation guidelines we developed a sensitive, selective, and accurate method for the simultaneous analysis CBD, CBDA, THC, and THCA-A in oils and THC & CBD in more complex matrices. This HPLC-MS/MS method was simple and reliable using standard sample dilution and homogenization, an isocratic chromatographic separation, and a triple quadrupole mass spectrometer. The lower limit of quantification (LLOQ) for analytes was 0.195 ng/mL over a 0.195-50.0 ng/mL range of quantification with a coefficient of correlation of >0.99. Average intra-day and inter-day accuracies were 94.2-112.7% and 97.2-110.9%, respectively. This method was used to quantify CBD, CBDA, THC, and THCA-A in 40 commercial hemp products representing a variety of matrices including oils, plant materials, and creams/cosmetics. All products tested met the federal regulatory restrictions on THC content in Canada (CBD, the majority of analyzed products contained low CBD levels and a CBD: CBDA ratio of CBD and a CBD: CBDA ratio of >1,000 (an oil-based product). Overall, the method proved amenable to the analysis of various commercial products including oils, creams, and plant material and may be diagnostically indicative of

  10. Analysis of radioactive corrosion test specimens by means of ICP-MS. Comparison with earlier methods

    International Nuclear Information System (INIS)

    Forsyth, Roy

    1997-07-01

    In June 1992, an ICP-MS instrument (Inductively Coupled Plasma-Mass Spectrometry) was commissioned for use with radioactive sample solutions at Studsvik Nuclear's Hot Cell Laboratory. For conventional environmental samples the instrument permits the simultaneous analysis of many trace elements, but the software used in evaluation of the mass spectra is based on a library of isotopic compositions relevant only for elements in the lithosphere. Fission products and actinides, however, have isotopic compositions which are significantly different from the natural elements, and which also vary with the burnup of the nuclear fuel specimen. Consequently, a spread-sheet had to be developed which could evaluate the mass spectra with these isotopic compositions. Following these preparations, a large number of samples (about 200) from SKB's experimental programme for the study of spent fuel corrosion have been analyzed by the ICP-MS technique. Many of these samples were archive solutions of samples which had been taken earlier in the programme. This report presents a comparison of the analytical results for uranium, plutonium, cesium, strontium and technetium by both the ICP-MS technique, and the previously used analytical methods. For three products, a satisfactory agreement between the results from the various methods was obtained, but for uranium and plutonium the ICP-MS method gave results which were 10-20% higher than the conventional methods. The comparison programme has also shown, not unexpectedly, that significant losses of plutonium from solution had occurred, by precipitation and/or absorption, in the archive solutions during storage. It can be expected that such losses also occur for the other actinides, and consequently, all the analytical results for actinides in older archive solutions must be treated with great caution. 9 refs

  11. Analysis of benzodiazepines and their metabolites using DBS cards and LC-MS/MS.

    Science.gov (United States)

    Lee, Heesang; Park, Yujin; Jo, Jiyeong; In, Sangwhan; Park, Yonghoon; Kim, Eunmi; Pyo, Jaesung; Choe, Sanggil

    2015-10-01

    Dried Blood Spot (DBS) has been used a blood extraction method for inherited metabolic disorder screening since 1960s. With introduction of LC-MS/MS, not only DBS could be used to analysis drugs in small blood volume, but in various fields, such as toxicology, drug therapeutic monitoring, drug diagnostic screening, and illicit drugs. In toxicology field, many drugs (e.g. benzodiazepines, acetaminophen, small molecule drugs) have been tested with DBS. Compared with earlier blood extraction methods (SPE and LLE), DBS has lots of advantages; lower blood volume (less than 50μL), shorter analysis time caused by a more concise analysis procedure and lower cost. We optimized the DBS procedure and LC-MS/MS conditions for 18 benzodiazepines, seven benzodiazepine metabolites, and one z-drug (zolpidem) analysis in blood. 30μL of whole blood was spotted on FTA DMPK card C and dried for 2h in a desiccator. A 6-mm disk was punched and vortexed for 1min in a centrifuge tube with 300μL methanol/acetonitrile mixture (1:1, v/v). After evaporation, redissolved in 100μL mobile phase of LC-MS/MS and 5μL was injected. In the analysis for 26 target compounds in blood, all of the method validation parameters - LLOD, LLOQ, accuracy (intra- and inter-assay), and precision (intra- and inter-assay) - were satisfied with method validation criteria, within 15%. The results of matrix effect, recovery, and process efficiency were good. We developed a fast and reliable sample preparation method using DBS for 26 benzodiazepines, benzodiazepine metabolites, and z-drug (zolpidem). Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  12. Comparative analysis of storage conditions and homogenization methods for tick and flea species for identification by MALDI-TOF MS.

    Science.gov (United States)

    Nebbak, A; El Hamzaoui, B; Berenger, J-M; Bitam, I; Raoult, D; Almeras, L; Parola, P

    2017-12-01

    Ticks and fleas are vectors for numerous human and animal pathogens. Controlling them, which is important in combating such diseases, requires accurate identification, to distinguish between vector and non-vector species. Recently, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) was applied to the rapid identification of arthropods. The growth of this promising tool, however, requires guidelines to be established. To this end, standardization protocols were applied to species of Rhipicephalus sanguineus (Ixodida: Ixodidae) Latreille and Ctenocephalides felis felis (Siphonaptera: Pulicidae) Bouché, including the automation of sample homogenization using two homogenizer devices, and varied sample preservation modes for a period of 1-6 months. The MS spectra were then compared with those obtained from manual pestle grinding, the standard homogenization method. Both automated methods generated intense, reproducible MS spectra from fresh specimens. Frozen storage methods appeared to represent the best preservation mode, for up to 6 months, while storage in ethanol is also possible, with some caveats for tick specimens. Carnoy's buffer, however, was shown to be less compatible with MS analysis for the purpose of identifying ticks or fleas. These standard protocols for MALDI-TOF MS arthropod identification should be complemented by additional MS spectrum quality controls, to generalize their use in monitoring arthropods of medical interest. © 2017 The Royal Entomological Society.

  13. Development and Optimization of an UPLC-QTOF-MS/MS Method Based on an In-Source Collision Induced Dissociation Approach for Comprehensive Discrimination of Chlorogenic Acids Isomers from Momordica Plant Species

    Directory of Open Access Journals (Sweden)

    N. E. Madala

    2014-01-01

    Full Text Available Chlorogenic acids (CGA have been profiled in the leaves of Momordica balsamina, Momordica charantia, and Momordica foetida. All three species were found to contain the trans and cis isomers of 4-acyl para-coumaroylquinic acid (pCoQA, caffeoylquinic acid (CQA, and feruloylquinic acid (FQA. To the best of our knowledge, this is the first report of pCoQA and FQA and their cis isomers in these Momordica species. These profiles were obtained by a newly developed UPLC-qTOF-MS method based on the in-source collision induced dissociation (ISCID method optimized to mimic the MS2 and MS3 fragmentation of an ion trap-based MS. The presence of the cis isomers is believed to be due to high UV exposure of these plants. Furthermore, the absence of the 3-acyl and 5-acyl CGA molecules points to a metabolic mark that is unusual and represents a very interesting biochemical phenotype of these species. Our optimized ISCID method was also shown to be able to distinguish between the geometrical isomers of all three forms of CGA, a phenomenon previously deemed impossible with other common mass spectrometry systems used for CGA analyses.

  14. Evaluation of a new preparative supercritical fluid chromatography system for compound library purification: the TharSFC SFC-MS Prep-100 system.

    Science.gov (United States)

    Ebinger, Katalin; Weller, Harold N; Kiplinger, Jeffrey; Lefebvre, Paul

    2011-06-01

    Preparative HPLC-MS is often the method of choice for purification of small amounts (libraries for drug discovery. The method is robust, well proven, and widely applicable. In contrast, preparative supercritical fluid chromatography coupled with mass spectrometry (SFC-MS) has seen only slow acceptance for the same application--despite some potential scientific and economic advantages. One of the reasons for slow adoption of SFC-MS is the lack of well-proven, robust, and commercially available instrumentation. In early 2009, TharSFC (a Waters Company, Pittsburgh, PA) introduced a new fully integrated system for preparative SFC-MS: The SFC-MS Prep-100. We report herein an objective evaluation of the SFC-MS Prep-100, including tests for pump and autosampler performance, sample recovery, sample carryover, fraction triggering, detector/fraction collector synchronization, and overall robustness. Our results suggest that the SFC-MS Prep-100 represents a significant advance over previous generation instrumentation. Copyright © 2011 Society for Laboratory Automation and Screening. Published by Elsevier Inc. All rights reserved.

  15. A validated LC–MS/MS method for the determination of tolterodine and its metabolite in rat plasma and application to pharmacokinetic study

    Directory of Open Access Journals (Sweden)

    Rihana Parveen Shaik

    2013-12-01

    Full Text Available Liquid chromatography–tandem mass spectrometry (LC–MS/MS method was used for simultaneous quantification of tolterodine and its metabolite 5-hydroxy methyl tolterodine in rat plasma. Tolterodine-d6 and 5-hydroxy methyl tolterodine-d14 were used as internal standards (IS. Chromatographic separation was performed on Ascentis Express RP amide (50 mm×4.6 mm, 2.7 μm column with an isocratic mobile phase composed of 10 mM ammonium acetate and acetonitrile in the ratio of 20:80 (v/v, at a flow-rate of 0.5 mL/min. Tolterodine, tolterodine-d6, 5-hydroxy methyl tolterodine and 5-hydroxy methyl tolterodine-d14 were detected with proton adducts at m/z 326.1→147.1, 332.3→153.1, 342.2→223.1 and 356.2→223.1 in multiple reaction monitoring (MRM positive mode respectively. The drug, metabolite and internal standards were extracted by liquid–liquid extraction method. The method was validated over a linear concentration range of 20.00–5000.00 pg/mL for tolterodine and 20.00–5000.00 pg/mL for 5-hydroxy methyl tolterodine. This method demonstrated intra- and inter-day precision of 0.62–6.36% and 1.73–4.84% for tolterodine, 1.38–4.22% and 1.62–4.25% for 5-hydroxy methyl tolterodine respectively. This method also demonstrated intra- and inter-day accuracy of 98.75–103.56% and 99.20–104.40% for tolterodine, 98.08–104.67% and 98.73–103.06% for 5-hydroxy methyl tolterodine respectively. Both analytes were found to be stable throughout freeze–thaw cycles, bench top and postoperative stability studies. This method was successfully applied for the pharmacokinetic analysis of rat plasma samples following i.v. administration. Keywords: LC–MS/MS, Tolterodine, 5-Hydroxy methyl tolterodine, Pharmacokinetics

  16. Application of ICP-MS and HPLC-ICP-MS for diagnosis and therapy of a severe intoxication with hexavalent chromium and inorganic arsenic.

    Science.gov (United States)

    Heitland, Peter; Blohm, Martin; Breuer, Christian; Brinkert, Florian; Achilles, Eike Gert; Pukite, Ieva; Köster, Helmut Dietrich

    2017-05-01

    ICP-MS and HPLC-ICP-MS were applied for diagnosis and therapeutic monitoring in a severe intoxication with a liquid containing hexavalent chromium (Cr(VI)) and inorganic arsenic (iAs). In this rare case a liver transplantation of was considered as the only chance of survival. We developed and applied methods for the determination of Cr(VI) in erythrocytes and total chromium (Cr) and arsenic (As) in blood, plasma, urine and liver tissue by ICP-MS. Exposure to iAs was diagnosed by determination of iAs species and their metabolites in urine by anion exchange HPLC-ICP-MS. Three days after ingestion of the liquid the total Cr concentrations were 2180 and 1070μg/L in whole blood and plasma, respectively, and 4540μg/L Cr(VI) in erythrocytes. The arsenic concentration in blood was 206μg/L. The urinary As species concentrations were <0.5, 109, 115, 154 and 126μg/L for arsenobetaine, As(III), As(V), methylarsonate (V) and dimethylarsinate (V), respectively. Total Cr and As concentrations in the explanted liver were 11.7 and 0.9mg/kg, respectively. Further analytical results of this case study are tabulated and provide valuable data for physicians and toxicologists. Copyright © 2017. Published by Elsevier GmbH.

  17. Structural and magnetic properties of Mg-Zn ferrites (Mg{sub 1−x}Zn{sub x}Fe{sub 2}O{sub 4}) prepared by sol-gel method

    Energy Technology Data Exchange (ETDEWEB)

    Reyes-Rodríguez, Pamela Yajaira, E-mail: pamela2244_4@hotmail.com [Cinvestav-Unidad Saltillo, Av. Industrial Metalúrgica #1062, Parque Industrial Saltillo-Ramos Arizpe, CP 25900, México (Mexico); Cortés-Hernández, Dora Alicia; Escobedo-Bocardo, José Concepción; Almanza-Robles, José Manuel; Sánchez-Fuentes, Héctor Javier; Jasso-Terán, Argentina; De León-Prado, Laura Elena [Cinvestav-Unidad Saltillo, Av. Industrial Metalúrgica #1062, Parque Industrial Saltillo-Ramos Arizpe, CP 25900, México (Mexico); Méndez-Nonell, Juan [Centro de Investigación en Materiales Avanzados, Ave. Miguel Cervantes #120, Complejo Industrial Chihuahua, CP 31109 Chihuahua, México (Mexico); Hurtado-López, Gilberto Francisco [Centro de Investigación en Química Aplicada, Blvd. Enrique Reyna Hermosillo #140, CP 25294 Saltillo, Coahuila, México (Mexico)

    2017-04-01

    In this study, the Mg{sub 1−x}Zn{sub x}Fe{sub 2}O{sub 4} nanoparticles (x=0–0.9) were prepared by sol-gel method. These ferrites exhibit an inverse spinel structure and the lattice parameter increases as the substitution of Zn{sup 2+} ions is increased. At lower Zn content (0.1≤x≤0.5), saturation magnetization (Ms) increases, while it decreases at higher Zn content (x≥6). The remnant magnetization (0.17–2.0 emu/g) and coercive field (6.0–60 Oe) indicate a ferrimagnetic behavior. The average core diameter of selected ferrites is around 15 nm and the nanoparticles morphology is quasi spherical. The heating ability of some Mg{sub 0.9}Zn{sub 0.1}Fe{sub 2}O{sub 4} and Mg{sub 0.7}Zn{sub 0.3}Fe{sub 2}O{sub 4} aqueous suspensions indicates that the magnetic nanoparticles can increase the medium temperature up to 42 °C in a time less than 10 min - Highlights: • Magnetic nanoparticles of Mg{sub 1−x}Zn{sub x}Fe{sub 2}O{sub 4} were synthesized by sol-gel method. • Nanoparticles showing a single spinel crystalline structure were obtained. • Aqueous suspensions of Mg{sub 0.7}Zn{sub 0.3}Fe{sub 2}O{sub 4} and Mg{sub 0.9}Zn{sub 0.1}Fe{sub 2}O{sub 4} show heating ability.

  18. MsLDR-creator: a web service to design msLDR assays.

    Science.gov (United States)

    Bormann, Felix; Dahl, Andreas; Sers, Christine

    2012-03-01

    MsLDR-creator is a free web service to design assays for the new DNA methylation detection method msLDR. The service provides the user with all necessary information about the oligonucleotides required for the measurement of a given CpG within a sequence of interest. The parameters are calculated by the nearest neighbour approach to achieve optimal behaviour during the experimental procedure. In addition, to guarantee a good start using msLDR, further information, like protocols and hints and tricks, are provided.

  19. Determination of ergocalciferol in human plasma after Diels-Alder derivatization by LC–MS/MS and its application to a bioequivalence study

    Directory of Open Access Journals (Sweden)

    Pritesh Contractor

    2017-12-01

    Full Text Available An accurate, sensitive and selective method is developed for determination of ergocalciferol (vitamin D2 in human plasma using LC–MS/MS. After liquid-liquid extraction with n-hexane, ergocalciferol was derivatized by reacting with 4-phenyl-1,2,4-triazoline-3,5-dione (PTAD, a strong dienophile based on Diels-Alder reaction. Ergocalciferol and its deuterated internal standard, ergocalciferol-d6, were analyzed on X Select CSH C18 (100 mm×4.6 mm, 2.5 µm column using acetonitrile and 0.1% (v/v formic acid in water containing 0.14% methylamine within 6.0 min under gradient elution mode. Tandem mass spectrometry in positive ionization mode was used to quantify ergocalciferol by multiple reaction monitoring (MRM. Entire data processing was done using Watson LIMS™ software which provided excellent data integrity and high throughput with improved operational efficiency. The major advantage of this method includes higher sensitivity (0.10 ng/mL, superior extraction efficiency (≥83% and small sample volume (100 µL for processing. The method was linear in the concentration range of 0.10–100 ng/mL for ergocalciferol. The intra-batch and inter-batch accuracy and precision (% CV values varied from 97.3% to 109.0% and 1.01% to 5.16%, respectively. The method was successfully applied to support a bioequivalence study of 1.25 mg ergocalciferol capsules in 12 healthy subjects. Keywords: Ergocalciferol, Diels-Alder reaction, 4-phenyl-1,2,4-triazoline-3,5-dione, LC–MS/MS, Human plasma

  20. Online identification of chlorogenic acids, sesquiterpene lactones, and flavonoids in the Brazilian arnica Lychnophora ericoides Mart. (Asteraceae) leaves by HPLC-DAD-MS and HPLC-DAD-MS/MS and a validated HPLC-DAD method for their simultaneous analysis.

    Science.gov (United States)

    Gobbo-Neto, Leonardo; Lopes, Norberto P

    2008-02-27

    Lychnophora ericoides Mart. (Asteraceae, Vernonieae) is a plant, endemic to Brazil, with occurrence restricted to the "cerrado" biome. Traditional medicine employs alcoholic and aqueous-alcoholic preparations of leaves from this species for the treatment of wounds, inflammation, and pain. Furthermore, leaves of L. ericoides are also widely used as flavorings for the Brazilian traditional spirit "cachaça". A method has been developed for the extraction and HPLC-DAD analysis of the secondary metabolites of L. ericoides leaves. This analytical method was validated with 11 secondary metabolites chosen to represent the different classes and polarities of secondary metabolites occurring in L. ericoides leaves, and good responses were obtained for each validation parameter analyzed. The same HPLC analytical method was also employed for online secondary metabolite identification by HPLC-DAD-MS and HPLC-DAD-MS/MS, leading to the identification of di- C-glucosylflavones, coumaroylglucosylflavonols, flavone, flavanones, flavonols, chalcones, goyazensolide, and eremantholide-type sesquiterpene lactones and positional isomeric series of chlorogenic acids possessing caffeic and/or ferulic moieties. Among the 52 chromatographic peaks observed, 36 were fully identified and 8 were attributed to compounds belonging to series of caffeoylferuloylquinic and diferuloylquinic acids that could not be individualized from each other.

  1. A new simple and rapid LC-ESI-MS/MS method for quantification of plasma oxysterols as dimethylaminobutyrate esters. Its successful use for the diagnosis of Niemann-Pick type C disease.

    Science.gov (United States)

    Boenzi, Sara; Deodato, Federica; Taurisano, Roberta; Martinelli, Diego; Verrigni, Daniela; Carrozzo, Rosalba; Bertini, Enrico; Pastore, Anna; Dionisi-Vici, Carlo; Johnson, David W

    2014-11-01

    Two oxysterols, cholestan-3β,5α,6β-triol (C-triol) and 7-ketocholesterol (7-KC), have been recently proposed as diagnostic markers of Niemann-Pick type C (NP-C) disease, representing a potential alternative diagnostic tool to the more invasive and time consuming filipin test in cultured fibroblasts. Usually, the oxysterols are detected and quantified by liquid chromatography-tandem mass spectrometry (LC-MS/MS) method using atmospheric pressure chemical ionization (APCI) or electro-spray-ionization (ESI) sources, after a variety of derivatization procedures to enhance sensitivity. We developed a sensitive LC-MS/MS method to quantify the oxysterols in plasma as dimethylaminobutyrate ester, suitable for ESI analysis. This method, with an easy liquid-phase extraction and a short derivatization procedure, has been validated to demonstrate specificity, linearity, recovery, lowest limit of quantification, accuracy and precision. The assay was linear over a concentration range of 0.5-200ng/mL for C-triol and 1.0-200ng/mL for 7-KC. Intra-day and inter-day coefficients of variation (CV%) were <15% for both metabolites. Receiver operating characteristic analysis estimates that the area under curve was 0.998 for C-triol, and 0.972 for 7-KC, implying a significant discriminatory power for the method in this patient population of both oxysterols. In summary, our method provides a simple, rapid and non-invasive diagnostic tool for the biochemical diagnosis of NP-C disease. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Anomalous tremor before 2008 Ms8. 0 Wenchuan earthquake: a review

    Directory of Open Access Journals (Sweden)

    Hao Xiaoguang

    2011-08-01

    Full Text Available In this paper we give a review of several previously published papers on anomalous tremors observed before the 2008 Ms8. 0 Wenchuan earthquake. Based on the observed time and frequency shifts between coastal and inland stations, we discussed some methods to distinguish different kinds of microseisms, and speculated that a pre-earthquake typhoon might have caused a “mainland-originated microseism” which in turn triggered the earthquake.

  3. HS-SPME-GC-MS/MS Method for the Rapid and Sensitive Quantitation of 2-Acetyl-1-pyrroline in Single Rice Kernels.

    Science.gov (United States)

    Hopfer, Helene; Jodari, Farman; Negre-Zakharov, Florence; Wylie, Phillip L; Ebeler, Susan E

    2016-05-25

    Demand for aromatic rice varieties (e.g., Basmati) is increasing in the US. Aromatic varieties typically have elevated levels of the aroma compound 2-acetyl-1-pyrroline (2AP). Due to its very low aroma threshold, analysis of 2AP provides a useful screening tool for rice breeders. Methods for 2AP analysis in rice should quantitate 2AP at or below sensory threshold level, avoid artifactual 2AP generation, and be able to analyze single rice kernels in cases where only small sample quantities are available (e.g., breeding trials). We combined headspace solid phase microextraction with gas chromatography tandem mass spectrometry (HS-SPME-GC-MS/MS) for analysis of 2AP, using an extraction temperature of 40 °C and a stable isotopologue as internal standard. 2AP calibrations were linear between the concentrations of 53 and 5380 pg/g, with detection limits below the sensory threshold of 2AP. Forty-eight aromatic and nonaromatic, milled rice samples from three harvest years were screened with the method for their 2AP content, and overall reproducibility, observed for all samples, ranged from 5% for experimental aromatic lines to 33% for nonaromatic lines.

  4. X-ray fluorescence method for trace analysis and imaging

    International Nuclear Information System (INIS)

    Hayakawa, Shinjiro

    2000-01-01

    X-ray fluorescence analysis has a long history as conventional bulk elemental analysis with medium sensitivity. However, with the use of synchrotron radiation x-ray fluorescence method has become a unique analytical technique which can provide tace elemental information with the spatial resolution. To obtain quantitative information of trace elemental distribution by using the x-ray fluorescence method, theoretical description of x-ray fluorescence yield is described. Moreover, methods and instruments for trace characterization with a scanning x-ray microprobe are described. (author)

  5. Development and validation of an improved method for the quantitation of sertraline in human plasma using LC-MS-MS and its application to bioequivalence studies.

    Science.gov (United States)

    Zhang, Mengliang; Gao, Feng; Cui, Xiangyong; Zhang, Yunhui; Sun, Yantong; Gu, Jingkai

    2011-02-01

    A rapid and sensitive LC-MS-MS method for the quantitation of sertraline in human plasma was developed and validated. Sertraline and the internal standard, telmisartan, were cleaned up by protein precipitation from 100 μL of plasma sample, and analyzed on a TC-C18 column (5 μm, 150 × 4.6 mm i.d.) using 70% acetonitrile and 30% 10 mM ammonium acetate (0.1% formic acid) as mobile phase. The method was demonstrated to be linear from 0.1 ng/mL to 50 ng/mL with the lower limit of quantitation of 0.1 ng/mL. Intra- and inter-day precision were below 4.40% and 3.55%. Recoveries of sertraline at low, medium, and high levels were 88.0 ± 2.3%, 88.2 ± 1.9%, and 90.0 ± 2.0%, respectively. The method was successfully applied to a bioequivalence study of sertraline after a single oral administration of 50 mg sertraline hydrochloride tablets.

  6. A validated UHPLC-MS/MS method to quantify low levels of anabolic-androgenic steroids naturally present in urine of untreated horses.

    Science.gov (United States)

    Decloedt, Anneleen; Bailly-Chouriberry, Ludovic; Vanden Bussche, Julie; Garcia, Patrice; Popot, Marie-Agnes; Bonnaire, Yves; Vanhaecke, Lynn

    2015-06-01

    Doping control is a main priority for regulatory bodies of both the horse racing industry and the equestrian sports. Urine and blood samples are screened for the presence of hundreds of forbidden substances including anabolic-androgenic steroids (AASs). Based on the suspected endogenous origin of some AASs, with β-boldenone as the most illicit candidate, this study aimed to improve the knowledge of the naturally present AAS in horse urine. To this extent, a novel ultra high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated according to the Association of Official Racing Chemists (AORC) and European Commission (EC) guidelines, proving the power of this new method. Low limits of detection (0.2 ng/mL), good reproducibility (percentage of standard deviation (%RSD)  0.99 and lack-of-fit analysis) were obtained for all included AASs. With this method, urine samples of 105 guaranteed untreated horses (47 geldings, 53 mares, and 5 stallions serving as a control) were screened for β-boldenone and five related natural steroids: androstadienedione (ADD), androstenedione (AED), alpha-testosterone (αT), beta-testosterone (βT), and progesterone (P). Progesterone, β-testosterone, and α-testosterone were detected in more than half of the horses at low concentrations (anabolic-androgenic steroids naturally present in urine of untreated horses (mares and geldings).

  7. Development of a GC-MS-SPME Method for the Determination of Amines in Meteorites

    Science.gov (United States)

    Hilts, R. W.; Skelhorne, A. W.; Simkus, D.; Herd, C. D. K.

    2016-08-01

    A GC-MS-SPME analytical method for the direct determination of amines in aqueous solution has been developed. The key step in the procedure is the conversion of the amines into their non-volatile ammonium salts by protonation with HCl.

  8. Development and validation of spectrofluorimetric and LC–MS/MS methods for the determination of hesperidin in human plasma and pharmaceutical forms

    Directory of Open Access Journals (Sweden)

    Pavun Leposava A.

    2012-01-01

    Full Text Available The spectrofluorometric method, based on fluorescence properties of aluminium (III–hesperidin complex, for the determination of hesperidin in human plasma and pharmaceutical forms has been developed and validated. The complex shows strong emission in the presence of surfactant betain sulfonate SB 12 at 476 nm with excitation at 390 nm. Linearity range in pharmaceutical forms of hesperidin was 0.06 – 24.4 μg mL-1 with LOD 0.016 μg mL-1 and LOQ 0.049 μg mL-1. Recovery values in the range 99.3 – 99.7% indicate good accuracy of the method. A linear dependence of the intensity of fluorescence of the complex on the concentration of hesperidin in plasma was obtained in concentration range from 0.1 – 12.2 μg mL-1. The LOD was 0.032 μg mL-1 while LOQ was 0.096 μg mL-1. Recovery values were in the range 98.4 – 99.8%. The reliability of the method was checked by LC-MS/MS method for plasma samples and HPLC/UV method for tablets with direct determination of hesperidin after separation. Linearity range in determination of hesperidin in pharmaceutical forms was obtained in the range from 0.05 to 10.00 μg mL-1. The LOD was 0.01 μg mL-1 and LOQ was 0.03 μg mL-1. Linearity range in plasma determination of hesperidin was 0.02 – 10.00 μg mL-1 with LOD 0.005 μg mL-1 and LOQ 0.015 μg mL-1. Good agreement between two methods indicate the usability of the proposed spectroflurometric method for the simple, precise and accurate determination of hesperidin in clinical and quality control laboratories.

  9. High-sensitive LC-MS/MS method for the simultaneous determination of mirodenafil and its major metabolite, SK-3541, in human plasma: application to microdose clinical trials of mirodenafil.

    Science.gov (United States)

    Cho, Doo-Yeoun; Bae, Soo Hyeon; Shon, Ji-Hong; Bae, Soo Kyung

    2013-03-01

    A high-sensitivity LC/MS/MS method was developed and validated for the simultaneous determination of mirodenafil and its major metabolite, SK-3541, in human plasma. Mirodenafil, SK-3541, and udenafil as an internal standard were extracted from plasma samples with methyl tert-butyl ether. Chromatographic separation was performed on a Luna phenyl-hexyl column (100 × 2.0 mm) with an isocratic mobile phase consisting of 5 mM ammonium formate and ACN (23:77, v/v) at a flow rate of 0.35 mL/min. Detection and quantification were performed using a mass spectrometer in selected reaction monitoring mode with positive ESI at m/z 532.3 → 296.1 for mirodenafil, m/z 488.1 → 296.1 for SK-3541, and m/z 517.3 → 283.2 for udenafil. The calibration curves were linear over a concentration range of 2-500 pg/mL using 0.5 mL plasma for the microdose of mirodenafil (100 μg). Analytical method validation of the clinical dose (100 mg), with a calibration curve range of 2-500 ng/mL using 0.025-mL plasma, was also conducted. The other LC-MS/MS conditions were similar to those used for the microdosing. Each method was applied successfully to pharmacokinetic studies after a microdose or clinical dose of mirodenafil to six healthy Korean male volunteers. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. LC-MS/MS methods for the determination of edaravone and/or taurine in rat plasma and its application to a pharmacokinetic study.

    Science.gov (United States)

    Tang, Dao-quan; Bian, Ting-ting; Zheng, Xiao-xiao; Li, Ying; Wu, Xiao-wen; Li, Yin-jie; Du, Qian; Jiang, Shui-shi

    2014-09-01

    Three liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods were respectively developed and validated for the simultaneous or independent determination of taurine and edaravone in rat plasma using 3-methyl-1-p-tolyl-5-pyrazolone and sulfanilic acid as the internal standards (IS). Chromatographic separations were achieved on an Agilent Zorbax SB-Aq (100 × 2.1 mm, 3.5 µm) column. Gradient 0.03% formic acid-methanol, isocratic 0.1% formic acid-methanol (90:10) and 0.02% formic acid-methanol (40:60) were respectively selected as the mobile phase for the simultaneous determination of two analytes, taurine or edaravone alone. The MS acquisition was performed in multiple reaction monitoring mode with a positive and negative electrospray ionization source. The mass transitions monitored were m/z [M + H](+) 175.1 → 133.0 and [M + H](+) 189.2 → 147.0 for edaravone and its IS, m/z [M - H](-) 124.1 → 80.0 and [M - H](-) 172.0 → 80.0 for taurine and its IS, respectively. The validated methods were successfully applied to study the pharmacokinetic interaction of taurine and edaravone in rats after independent intravenous administration and co-administration with a single dose. Our collective results showed that there were no significant alterations on the main pharmacokinetic parameters (area under concentration-time curve, mean residence time, half-life and clearance) of taurine and edaravone, implying that the proposed combination therapy was pharmacologically feasible. Copyright © 2014 John Wiley & Sons, Ltd.

  11. An IC-MS/MS Method for the Determination of 1-Hydroxyethylidene-1,1-diphosphonic Acid on Uncooked Foods Treated with Peracetic Acid-Based Sanitizers.

    Science.gov (United States)

    Suzuki, Ippei; Kubota, Hiroki; Ohtsuki, Takashi; Tatebe, Chiye; Tada, Atsuko; Yano, Takeo; Akiyama, Hiroshi; Sato, Kyoko

    2016-01-01

    A rapid, sensitive, and specific analytical method for the determination of 1-hydroxyethylidene-1,1-diphosphonic acid (HEDP) on uncooked foods after treatment with a peracetic acid-based sanitizer (PAS) was developed. The method involves simple sample preparation steps and analysis using ion chromatography (IC) coupled with tandem mass spectrometry (MS/MS). The quantification limits of HEDP on uncooked foods are 0.007 mg/kg for vegetables and fruits and 0.2 mg/kg for meats. The recovery and relative standard deviation (RSD) of HEDP analyses of uncooked foods ranged from 73.9 to 103.8% and 1.9 to 12.6%, respectively. The method's accuracy and precision were evaluated by inter-day recovery tests. The recovery for all samples ranged from 93.6 to 101.2%, and the within-laboratory repeatability and reproducibility were evaluated based on RSD values, which were less than 6.9 and 11.5%, respectively. Analyses of PAS-treated fruits and vegetables using the developed method indicated levels of HEDP ranging from 0.008 to 0.351 mg/kg. Therefore, the results of the present study suggest that the proposed method is an accurate, precise, and reliable way to determine residual HEDP levels on PAS-treated uncooked foods.

  12. Antibiotic use in heavy pigs: Comparison between urine and muscle samples from food chain animals analysed by HPLC-MS/MS.

    Science.gov (United States)

    Chiesa, Luca Maria; Nobile, Maria; Panseri, Sara; Arioli, Francesco

    2017-11-15

    The antibiotic overuse in zoothechnics, due to prophylactic and therapeutic treatments, or to their growth-promoting activity, is a major cause for the onset of widespread antibiotic resistance. Of particular relevance to this study, is the antibiotic abuse in pig breeding. Despite the comprehensive literature on residue controls in pig muscle, data on pig urine, a non-invasive, on-farm collectable matrix, are lacking. Therefore, we validated an HPLC-MS/MS method to detect 29 antimicrobials from eight classes and applied it to 43 anonymous pig urine and muscle paired samples and fulfilled the parameters in agreement with the Commission Decision 2002/657/UE. The analytical limits were moreover much lower than the maximum residue limits (MRLs) required by the Commission Regulation 37/2010/UE. In the samples, antibiotics were usually detected at higher frequencies and concentrations in urine than muscle. Urine proved a useful tool to detect antibiotic administration and their excessive use in pig farming is depicted. Copyright © 2017. Published by Elsevier Ltd.

  13. Ultra-performance liquid chromatography MS/MS method for the determination of parabens in compost from sewage sludge: comparison of the efficiency of two extraction techniques.

    Science.gov (United States)

    Benítez-Villalba, Julio César; Zafra-Gómez, Alberto; Dorival-García, Noemí; Camino-Sánchez, Francisco Javier; Cantarero, Samuel; Vílchez, José Luis

    2013-08-01

    The efficiency of two extraction techniques--ultrasound-assisted extraction and pressurized liquid extraction--are compared and evaluated in the determination of parabens in compost samples. The extraction parameters for each technique were accurately optimized. The selected compounds were detected and quantified using ultra-performance LC MS/MS, operating in negative ESI and in SRM mode. The analytes were separated in less than 5 min. Ethylparaben (ring-(13)C6 labeled) was used as an internal standard. Two selective, sensitive, and accurate analytical methods were developed and validated. The LODs of the methods ranged from 3 to 7 ng/g and the LOQs from 10 to 23 ng/g, while inter- and intraday variability was under 6% in all cases. The methods were validated separately by using matrix-matched calibration and recovery assays with spiked samples. Recovery rates ranged from 94.0 to 105.0%. Compost samples were taken from different composting plants. Although the statistical comparison demonstrated no statistically significant differences between the two extraction techniques, the method based on pressurized liquid extraction was more sensitive than the ultrasound extraction based method. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Comparison of x-ray output of inverter-type x-ray equipment

    International Nuclear Information System (INIS)

    Asano, Hiroshi; Miyake, Hiroyuki; Yamamoto, Keiichi

    2000-01-01

    The x-ray output of 54 inverter-type x-ray apparatuses used at 18 institutions was investigated. The reproducibility and linearity of x-ray output and variations among the x-ray equipment were evaluated using the same fluorescence meter. In addition, the x-ray apparatuses were re-measured using the same non-invasive instrument to check for variations in tube voltage, tube current, and irradiation time. The non-invasive instrument was calibrated by simultaneously obtaining measurements with an invasive instrument, employing the tube voltage and current used for the invasive instrument, and the difference was calculated. Reproducibility of x-ray output was satisfactory for all x-ray apparatuses. The coefficient of variation was 0.04 or less for irradiation times of 5 ms or longer. In 84.3% of all x-ray equipment, variation in the linearity of x-ray output was 15% or less for an irradiation time of 5 ms. However, for all the apparatuses, the figure was 50% when irradiation time was the shortest (1 to 3 ms). Variation in x-ray output increased as irradiation time decreased. Variation in x-ray output ranged between 1.8 and 2.5 compared with the maximum and minimum values, excluding those obtained at the shortest irradiation time. The relative standard deviation ranged from ±15.5% to ±21.0%. The largest variation in x-ray output was confirmed in regions irradiated for the shortest time, with smaller variations observed for longer irradiation times. The major factor responsible for variation in x-ray output in regions irradiated for 10 ms or longer, which is a relatively long irradiation time, was variation in tube current. Variation in tube current was slightly greater than 30% at maximum, with an average value of 7% compared with the preset tube current. Variations in x-ray output in regions irradiated for the shortest time were due to photographic effects related to the rise and fall times of the tube voltage waveform. Accordingly, in order to obtain constant x

  15. Rapid and Sensitive LC-MS/MS Method for the Determination of Metoprolol in Beagle Dog Plasma with a Simple Protein Precipitation Treatment and Its Pharmacokinetic Applications

    Directory of Open Access Journals (Sweden)

    Aihua Hong

    2012-03-01

    Full Text Available : A rapid LC-MS/MS method with good accuracy and sensitivity was developed and validated for the pharmacokinetics study of metoprolol (MP in beagle dogs. The plasma samples were simply precipitated by methanol and then analyzed by LC-MS/MS. An Ultimate XB-C18 column (150 × 2.1 mm ID, 5 μm was used for separation, with methanol-water containing 0.2% formic acid (65:35, v/v as the mobile phase at a flow rate of 0.2 mL/min. Monitoring ions of MP and internal standard (hydroxypioglitazone were m/z 268.1/115.6 and m/z 373.1/150.2, respectively. The linear range was 3.03–416.35 ng/mL with an average correlation coefficient of 0.9996, and the limit of quantification was 3.03 ng/mL. The intra- and inter-day precision was less than 15%. At low, middle and high concentrations, the recovery, the matrix effect and the accuracy was in the range of 76.06%–95.25%, 93.67%–104.19% and 95.20%–99.96% respectively. The method was applied for the pharmacokinetics study of MP tartrate tablets (50 mg. The AUC0-t, Tmax and Cmax were respectively 919.88 ± 195.67 μg/L·h, 0.96 ± 0.33 h, 349.12 ± 78.04 ng/mL.

  16. Create, run, share, publish, and reference your LC-MS, FIA-MS, GC-MS, and NMR data analysis workflows with the Workflow4Metabolomics 3.0 Galaxy online infrastructure for metabolomics.

    Science.gov (United States)

    Guitton, Yann; Tremblay-Franco, Marie; Le Corguillé, Gildas; Martin, Jean-François; Pétéra, Mélanie; Roger-Mele, Pierrick; Delabrière, Alexis; Goulitquer, Sophie; Monsoor, Misharl; Duperier, Christophe; Canlet, Cécile; Servien, Rémi; Tardivel, Patrick; Caron, Christophe; Giacomoni, Franck; Thévenot, Etienne A

    2017-12-01

    Metabolomics is a key approach in modern functional genomics and systems biology. Due to the complexity of metabolomics data, the variety of experimental designs, and the multiplicity of bioinformatics tools, providing experimenters with a simple and efficient resource to conduct comprehensive and rigorous analysis of their data is of utmost importance. In 2014, we launched the Workflow4Metabolomics (W4M; http://workflow4metabolomics.org) online infrastructure for metabolomics built on the Galaxy environment, which offers user-friendly features to build and run data analysis workflows including preprocessing, statistical analysis, and annotation steps. Here we present the new W4M 3.0 release, which contains twice as many tools as the first version, and provides two features which are, to our knowledge, unique among online resources. First, data from the four major metabolomics technologies (i.e., LC-MS, FIA-MS, GC-MS, and NMR) can be analyzed on a single platform. By using three studies in human physiology, alga evolution, and animal toxicology, we demonstrate how the 40 available tools can be easily combined to address biological issues. Second, the full analysis (including the workflow, the parameter values, the input data and output results) can be referenced with a permanent digital object identifier (DOI). Publication of data analyses is of major importance for robust and reproducible science. Furthermore, the publicly shared workflows are of high-value for e-learning and training. The Workflow4Metabolomics 3.0 e-infrastructure thus not only offers a unique online environment for analysis of data from the main metabolomics technologies, but it is also the first reference repository for metabolomics workflows. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Method for taking X radiographs

    International Nuclear Information System (INIS)

    Orth, G.

    1983-01-01

    The method is aimed at obtaining X radiographs of any human organ with the aid of an X-ray-shadowless radiation detector of a dose measuring device, which is arranged between patient and imaging system, and of a controlling microprocessor system, so that the image-forming parameters are automatically adjusted to the specific properties of the patient. This procedure minimices the efforts in preparing the radiograph and the radiation exposure of the patient

  18. LC-MS characterization of valsartan degradation products and comparison with LC-PDA

    Directory of Open Access Journals (Sweden)

    Sumaia Araújo Pires

    2015-12-01

    Full Text Available abstract Valsartan was submitted to forced degradation under acid hydrolysis condition as prescribed by the ICH. Degraded sample aliquots were separated via HPLC using a Hypersil ODS (C18 column (250 x 4.6 mm i.d., 5 µm. Either photodiode array (PDA detection or mass spectrometry (MS full scan monitoring of HPLC runs were used. HPLC-PDA failed to indicate Valsartan degradation under forced acid degradation, showing an insignificant peak area variation and that Valsartan apparently remained pure. HPLC-MS using electrospray ionization (ESI and total ionic current (TIC monitoring did not reveal any peak variation either, but inspection of the ESI mass spectra showed the appearance of m/z 306 and m/z 352 ions for the same retention time as that of Valsartan (m/z 436. These ions were identified as being protonated molecules of two co-eluting degradation products formed by hydrolysis. These assignments were confirmed by ESI-MS/MS with direct infusion of the degraded samples. The results showed that the use of selective HPLC-MS is essential for monitoring Valsartan degradation. Efficient HPLC separation coupled to selective and structural diagnostic MS monitoring seems therefore mandatory for comprehensive drug degradation studies, particularly for new drugs and formulations, and for method development.

  19. Native MS and ECD Characterization of a Fab-Antigen Complex May Facilitate Crystallization for X-ray Diffraction

    Science.gov (United States)

    Zhang, Ying; Cui, Weidong; Wecksler, Aaron T.; Zhang, Hao; Molina, Patricia; Deperalta, Galahad; Gross, Michael L.

    2016-07-01

    Native mass spectrometry (MS) and top-down electron-capture dissociation (ECD) combine as a powerful approach for characterizing large proteins and protein assemblies. Here, we report their use to study an antibody Fab (Fab-1)-VEGF complex in its near-native state. Native ESI with analysis by FTICR mass spectrometry confirms that VEGF is a dimer in solution and that its complex with Fab-1 has a binding stoichiometry of 2:2. Applying combinations of collisionally activated dissociation (CAD), ECD, and infrared multiphoton dissociation (IRMPD) allows identification of flexible regions of the complex, potentially serving as a guide for crystallization and X-ray diffraction analysis.

  20. Using solution- and solid-state S K-edge X-ray absorption spectroscopy with density functional theory to evaluate M-S bonding for MS4(2-) (M = Cr, Mo, W) dianions.

    Science.gov (United States)

    Olson, Angela C; Keith, Jason M; Batista, Enrique R; Boland, Kevin S; Daly, Scott R; Kozimor, Stosh A; MacInnes, Molly M; Martin, Richard L; Scott, Brian L

    2014-12-14

    Herein, we have evaluated relative changes in M-S electronic structure and orbital mixing in Group 6 MS4(2-) dianions using solid- and solution-phase S K-edge X-ray absorption spectroscopy (XAS; M = Mo, W), as well as density functional theory (DFT; M = Cr, Mo, W) and time-dependent density functional theory (TDDFT) calculations. To facilitate comparison with solution measurements (conducted in acetonitrile), theoretical models included gas-phase calculations as well as those that incorporated an acetonitrile dielectric, the latter of which provided better agreement with experiment. Two pre-edge features arising from S 1s → e* and t electron excitations were observed in the S K-edge XAS spectra and were reasonably assigned as (1)A1 → (1)T2 transitions. For MoS4(2-), both solution-phase pre-edge peak intensities were consistent with results from the solid-state spectra. For WS4(2-), solution- and solid-state pre-edge peak intensities for transitions involving e* were equivalent, while transitions involving the t orbitals were less intense in solution. Experimental and computational results have been presented in comparison to recent analyses of MO4(2-) dianions, which allowed M-S and M-O orbital mixing to be evaluated as the principle quantum number (n) for the metal valence d orbitals increased (3d, 4d, 5d). Overall, the M-E (E = O, S) analyses revealed distinct trends in orbital mixing. For example, as the Group 6 triad was descended, e* (π*) orbital mixing remained constant in the M-S bonds, but increased appreciably for M-O interactions. For the t orbitals (σ* + π*), mixing decreased slightly for M-S bonding and increased only slightly for the M-O interactions. These results suggested that the metal and ligand valence orbital energies and radial extensions delicately influenced the orbital compositions for isoelectronic ME4(2-) (E = O, S) dianions.

  1. Solar photocatalytic disinfection of E. coli and bacteriophages MS2, ΦX174 and PR772 using TiO2, ZnO and ruthenium based complexes in a continuous flow system.

    Science.gov (United States)

    Mac Mahon, Joanne; Pillai, Suresh C; Kelly, John M; Gill, Laurence W

    2017-05-01

    The performance of photocatalytic treatment processes were assessed using different photocatalysts against E. coli and bacteriophages MS2, ΦX174 and PR772, in a recirculating continuous flow compound parabolic collector system under real sunlight conditions. Suspended TiO 2 and ZnO nanoparticle powders and Tris(2,2'-bipyridyl)dichlororuthenium(II) hexahydrate in solution were tested separately, as well as in combination, using E. coli. For a 3-log reduction of E. coli in distilled water, inactivation rates in terms of cumulative dose were in the order Ru(bpy) 3 Cl 2 >(TiO 2 & Ru(bpy) 3 Cl 2 )>(ZnO & Ru(bpy) 3 Cl 2 )>ZnO>TiO 2 >photolysis. Reactivation of E. coli was observed following all trials despite the detection limit being reached, although the reactivated colonies were observed to be under stress and much slower growing when compared to original colonies. Treatment with Ru(bpy) 3 Cl 2 was also compared against standard photolysis of bacteriophages MS2, ΦX174 and PR772 with the order of photolytic inactivation for a 3-log reduction in terms of cumulative UV-A dose being ΦX174>PR772>MS2. However, MS2 was found to be the most susceptible bacteriophage to treatment with Ru(bpy) 3 Cl 2 , with complete removal of the phage observed within the first 15min of exposure. Ru(bpy) 3 Cl 2 also significantly improved inactivation rates for PR772 and ΦX174. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Signal regulatory protein α associated with the progression of oral leukoplakia and oral squamous cell carcinoma regulates phenotype switch of macrophages.

    Science.gov (United States)

    Ye, Xiaojing; Zhang, Jing; Lu, Rui; Zhou, Gang

    2016-12-06

    Signal regulatory protein α (SIRPα) is a cell-surface protein expressed on macrophages that are regarded as an important component of the tumor microenvironment. The expression of SIRPα in oral leukoplakia (OLK) and oral squamous cell carcinoma (OSCC), and further explored the role of SIRPα on the phenotype, phagocytosis ability, migration, and invasion of macrophages in OSCC were investigated. The expression of SIRPα in OLK was higher than in OSCC, correlating with the expression of CD68 and CD163 on macrophages. After cultured with the conditioned media of oral cancer cells, the expression of SIRPα on THP-1 cells was decreased gradually. In co-culture system, macrophages were induced into M2 phenotype by oral cancer cells. Blockade of SIRPα inhibited phagocytosis ability and IL-6, TNF-α productions of macrophages. In addition, the proliferation, migration, and IL-10, TGF-β productions of macrophages were upregulated after blockade of SIRPα. Macrophages upregulated the expression of SIRPα and phagocytosis ability, and inhibited the migration and invasion when the activation of NF-κB was inhibited by pyrrolidine dithiocarbamate ammonium (PDTC). Hence, SIRPα might play an important role in the progression of OLK and oral cancer, and could be a pivotal therapeutic target in OSCC by regulating the phenotype of macrophages via targeting NF-κB.

  3. Two methods for studying the X-ray variability

    NARCIS (Netherlands)

    Yan, Shu-Ping; Ji, Li; Méndez, Mariano; Wang, Na; Liu, Siming; Li, Xiang-Dong

    2016-01-01

    The X-ray aperiodic variability and quasi-periodic oscillation (QPO) are the important tools to study the structure of the accretion flow of X-ray binaries. However, the origin of the complex X-ray variability from X-ray binaries remains yet unsolved. We proposed two methods for studying the X-ray

  4. Quantification of free and total sialic acid excretion by LC-MS/MS

    NARCIS (Netherlands)

    van der Ham, Maria; Prinsen, Berthil H. C. M. T.; Huijmans, Jan G. M.; Abeling, Nicolaas G. G. M.; Dorland, Bert; Berger, Ruud; de Koning, Tom J.; de Sain-van der Velden, Monique G. M.

    2007-01-01

    The main purpose for measuring urinary free sialic acid (FSA) is to diagnose sialic acid (SA) storage diseases. Elevated amounts of conjugated sialic acid (CSA) are observed in several diseases indicating the need to quantify CSA as well. A LC-MS/MS method for quantification of FSA and total sialic

  5. Simultaneous Determination of Seven Components in Rat Plasma by the UPLC-MS/MS Method and Application of Pharmacokinetic Studies to SimiaoYong’an Decoction

    Directory of Open Access Journals (Sweden)

    Yuanyan Liu

    2017-11-01

    Full Text Available SimiaoYong’an Decoction (SYD is a classical traditional Chinese prescription that is used for the treatment of gangrene, heat-clearing, detoxification and pain alleviation. We developed a sensitive ultra-performance liquid chromatography-tandem mass spectrum (UPLC-MS/MS method for the simultaneous determination of seven major active ingredients of SYD extract (i.e., harpagide, chlorogenic acid, sweroside, loganin, liquiritin, angoroside C and harpagoside in rat plasma. The preliminary steps in the plasma analysis were the addition of an internal standard such as linarin, followed by protein precipitation with methanol. Separation of the active ingredients was performed on an ACQUITY UPLC® BEH C18 column (100 mm × 2.1 mm, 1.7 μm at a flow rate of 0.2 mL/min with methanol/water 0.1% formic acid aqueous (V/V as the mobile phase. Detection was performed on a triple quadrupole tandem MS (QqQ-MS via negative ion electrospray ionization in multiple reactions monitoring (MRM mode. All calibration curves showed good linearity (r > 0.99 over the concentration range with a low limit of quantification between 0.029 and 5.813 ng/mL. Precision was evaluated by intra-day and inter-day assays, and the percentages of the RSD were all within 8.1%. The extraction efficiency and matrix effect were 80.6–113.6% and 82.9–99.5%, respectively. The validated method was successfully applied to a pharmacokinetic study in rats after oral administration of SYD extract and the corresponding single and combined traditional Chinese medicines (TCMs. The pharmacokinetic properties of the seven ingredients showed dynamic changes due to counteraction among the different coexisting components. The established approach has proven useful in the study of the active constituents in a traditional Chinese prescription.

  6. Surfactant-free microemulsion electrokinetic chromatography (SF-MEEKC) with UV and MS detection - a novel approach for the separation and ESI-MS detection of neutral compounds.

    Science.gov (United States)

    Mohorič, Urška; Beutner, Andrea; Krickl, Sebastian; Touraud, Didier; Kunz, Werner; Matysik, Frank-Michael

    2016-12-01

    Microemulsion electrokinetic chromatography (MEEKC) is a powerful tool to separate neutral species based on differences in their hydrophobic and hydrophilic properties. However, as a major drawback the conventionally used SDS based microemulsions are not compatible with electrospray ionization mass spectrometry (ESI-MS). In this work, a surfactant-free microemulsion (SFME) consisting of water, ethanol, and 1-octanol is used for surfactant-free microemulsion electrokinetic chromatography (SF-MEEKC). Ammonium acetate was added to the SFME enabling electrophoretic separations. The stability of SFMEs containing ammonium acetate was investigated using small-angle X-ray scattering and dynamic light scattering. A method for the separation of a model system of hydrophobic and hydrophilic neutral vitamins, namely the vitamins B 2 and D 3 , and the cationic vitamin B 1 was developed using UV/VIS detection. The influence of the ammonium acetate concentration on the separation performance was studied in detail. The method was characterized concerning reproducibility of migration times and peak areas and concerning the linearity of the calibration data. Furthermore, SF-MEEKC was coupled to ESI-MS investigating the compatibility between SFMEs and the ESI process. The signal intensities of ESI-MS measurements of the model analytes were comparable for SFMEs and aqueous systems. Finally, the vitamin D 3 content of a drug treating vitamin D 3 deficiency was determined by SF-MEEKC coupled to ESI-MS using 25-hydroxycholecalciferol as an internal standard. Graphical abstract The concept of surfactant-free microemulsion electrokinetic chromatography coupled to electrospray ionization mass spectrometry.

  7. α-Glucosidase inhibition and antioxidant activity of an oenological commercial tannin. Extraction, fractionation and analysis by HPLC/ESI-MS/MS and (1)H NMR.

    Science.gov (United States)

    Muccilli, Vera; Cardullo, Nunzio; Spatafora, Carmela; Cunsolo, Vincenzo; Tringali, Corrado

    2017-01-15

    Two batches of the oenological tannin Tan'Activ R, (toasted oak wood - Quercus robur), were extracted with ethanol. A fractionation on XAD-16 afforded four fractions for each extract. Extracts and fractions were evaluated for antioxidant activity (DPPH), polyphenol content (GAE) and yeast α-glucosidase inhibitory activity. Comparable results were obtained for both columns, fractions X1B and X2B showing the highest antioxidant activity. Fractions X1C and X2C notably inhibited α-glucosidase, with IC50=9.89 and 8.05μg/mL, respectively. Fractions were subjected to HPLC/ESI-MS/MS and (1)H NMR analysis. The main phenolic constituents of both X1B and X2B were a monogalloylglucose isomer (1), a HHDP-glucose isomer (2), castalin (3) gallic acid (4), vescalagin (5), and grandinin (or its isomer roburin E, 6). X1C and X2C showed a complex composition, including non-phenolic constituents. Fractionation of X2C gave a subfraction, with enhanced α-glucosidase inhibitory activity (IC50=6.15μg/mL), with castalagin (7) as the main constituent. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Determination of post-culture processing with carbohydrates by MALDI-MS and TMS derivatization GC-MS.

    Science.gov (United States)

    Wunschel, David S; Wahl, Karen L; Melville, Angela M; Sorensen, Christina M; Colburn, Heather A; Valentine, Nancy B; Stamper, Casey L

    2011-10-15

    Biological materials generally require stabilization to retain activity or viability in a dry form. A number of industrial products, such as vaccines, probiotics and biopesticides have been produced as dry preparations. The same methods and materials used for stabilizing commercial microbial products may be applicable to preserving biothreat pathogens in a dry form. This is a likely step that may be encountered when looking at samples from terrorism attempts since only spores, such as those from Bacillus anthracis, are inherently stable when dried. The stabilizers for microbial preparations generally include one or more small carbohydrates. Different formulations have been reported for different industrial products and are often determined empirically. However sugar alcohols (mannitol and sorbitol) and disaccharides (lactose, sucrose and trehalose) are the common constituents of these formulations. We have developed an analytical method for sample preparation and detection of these simple carbohydrates using two complementary analytical tools, MALDI-MS and GC-MS. The native carbohydrates and other constituents of the formulation are detected by MALDI-MS as a screening tool. A longer and more detailed analysis is then used to specifically identify the carbohydrates by derivatization and GC-MS detection. Both techniques were tested against ten different types of stabilization recipes with Yersinia pestis cell mass cultured on different media types used as the biological component. A number of additional components were included in these formulations including proteins and peptides from serum or milk, polymers (e.g. poly vinyl pyrrolidone - PVP) and detergents (e.g. Tween). The combined method was characterized to determine several figures of merit. The accuracy of the method was 98% for MALDI-MS and 100% for GC-MS. The repeatability for detection of carbohydrates by MALDI-MS was determined to be 96%. The repeatability of compound identification by GC-MS was

  9. Analysis of banned veterinary drugs and herbicide residues in shellfish by liquid chromatography-tandem mass spectrometry (LC/MS/MS) and gas chromatography-tandem mass spectrometry (GC/MS/MS)

    International Nuclear Information System (INIS)

    Chang, Geng-Ruei; Chen, Hui-Shan; Lin, Feng-Yi

    2016-01-01

    Seafood safety is a crucial public health concern for consumers. In this study, we applied a validated method to analyze the residue of banned veterinary drugs in shellfish, namely chloramphenicol, malachite green, leucomalachite green, and nitrofuran metabolites; additionally, the QuEChERS method was employed to detect 76 herbicides by LC/MS/MS and GC/MS/MS. In total, 42 shellfish samples, which included hard clams, freshwater clams, and oysters, were collected from aquafarms and production areas in Taiwan during 2012. Our results revealed 3.8 ng/g of chloramphenicol in one hard clam, 19.9–32.1 ng/g of ametryn in two hard clams, 16.1–60.1 ng/g of pendimethalin in four hard clams, and 17.0 ng/g of mefenacet in one oyster, indicating that 19.1% of the samples contained residues from banned veterinary drugs and pesticides. These data can be used to monitor the residue of veterinary drugs and pesticides in aquatic organisms and as a reference for food safety. - Highlights: • A certified method was employed for analyzing residues of banned veterinary drugs and herbicides in shellfish samples. • The trace levels of chloramphenicol, ametryn, pendimethalin were detected in hard clam samples. • For ensuring food safety, continual monitoring of aquatic products is necessary.

  10. A semi-automated LC-MS/MS method for the determination of LCI699, a steroid 11β-hydroxylase inhibitor, in human plasma.

    Science.gov (United States)

    Li, Wenkui; Luo, Suyi; Rebello, Sam; Flarakos, Jimmy; Tse, Francis L S

    2014-06-01

    A novel liquid chromatographic method with tandem mass spectrometric detection (LC-MS/MS) for the determination of LCI699 was developed and validated with dynamic ranges of 0.0500-50.0 ng/mL and 1.00-1,000 ng/mL using 0.0500 mL and 0.100mL, respectively, of human plasma. LCI699 and the internal standard, [M+6]LCI699, were extracted from fortified human plasma via protein precipitation. After transfer or dilution of the supernatant followed by solvent evaporation and/or reconstitution, the extract was injected onto the LC-MS/MS system. Optimal chromatographic separation was achieved on an ACE C18 (50 mm × 4.6mm, 3 μm) column with 30% aqueous methanol (containing 0.5% acetic acid and 0.05% TFA) as the mobile phase run in isocratic at a flow rate of 1.0 mL/min. The total analysis cycle time is approximately 3.5 min per injection. The addition of an ion-pair reagent, TFA (0.05%, v/v), to the mobile phases significantly improved the chromatographic retention and resolution of the analyte on silica based reversed-phase column. Although addition of TFA to the mobile phase suppresses the ESI signals of the analyte due to its ion-pairing characteristics in the gas phase of MS source, this negative impact was effectively alleviated by adding 0.5% acetic acid to the mobile phase. The current method was validated for sensitivity, selectivity, linearity, reproducibility, stability and recovery. For the low curve range (0.0500-50.0 ng/mL), the accuracy and precision for the LLOQs (0.0500 ng/mL) were -13.0 to 2.0% bias and 3.4-19.2% CV, respectively. For other QC samples (0.100, 6.00, 20.0 and 40.0 ng/mL), the precision ranged from 1.2 to 9.0% and from 3.8 to 8.8% CV, respectively, in the intra-day and inter-day evaluations. The accuracy ranged from -11.3 to 8.0% and -7.2 to 1.6% bias, respectively, in the intra-day and inter-day batches. For the high curve range (1.00-1,000 ng/mL), the accuracy and precision for the LLOQs (1.00 ng/mL) were 1.0-15.0% bias and 7.4-9.2% CV

  11. Forensic investigation of brick stones using instrumental neutron activation analysis (INAA), laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) and X-ray fluorescence analysis (XRF)

    International Nuclear Information System (INIS)

    Scheid, Nicole; Becker, Stefan; Duecking, Marc; Hampel, Gabriele; Volker Kratz, Jens; Watzke, Peter; Weis, Peter; Zauner, Stephan

    2009-01-01

    Brick stones collected from different production facilities were studied for their elemental compositions under forensic aspects using laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS), instrumental neutron activation analysis (INAA) and X-ray fluorescence analysis (XRF). The aim of these examinations was to assess the potential of these methods in forensic comparison analyses of brick stones. The accuracy of the analysis methods was evaluated using NIST standard reference materials (679, 98b and 97b). In order to compare the stones to each other, multivariate data analysis was used. The evaluation of the INAA results (based on the concentrations of V, Na, K, Sm, U, Sc, Fe, Co, Rb and Cs) using principal component analysis (PCA) and cluster analysis is presented as an example. The results derived from the different analytical methods are consistent. It was shown that elemental analysis using the described methods is a valuable tool for forensic examinations of brick stones.

  12. Development of a UPLC-ESI-MS/MS method for the determination of larotaxel in beagle dog plasma: application to the pharmacokinetic study.

    Science.gov (United States)

    Liu, Zhenzhen; Zhang, Bo; Liu, Zhihong; Li, Song; Li, Guofei; Geng, Lulu; Zhao, Xu; Bi, Kaishun; Tang, Xing; Chen, Xiaohui

    2012-04-01

    A UPLC-ESI-MS/MS method has been developed and validated for the determination of larotaxel in beagle dog plasma. After addition of the internal standard, plasma samples were extracted by liquid-liquid extraction with methyl tert-butyl ether and separated on a 50×2.1 mm ACQUITY 1.7 μm C18 column (Waters, USA), with acetonitrile and 5 mM ammonium acetate as mobile phase, within a runtime of 3.0 min. The analytes were detected without interference in Multiple Reaction Monitoring mode with positive electrospray ionization. The linear range was 2.5-5,000 ng/mL. The intra-day and inter-day precisions (relative standard deviation, RSD, %) were within 9.3% and 10.2%, respectively, and the accuracy (relative error, RE, %) was less than 11.5%. The validated method was successfully applied to a pharmacokinetic study of larotaxel in beagle dogs after intravenous administration of larotaxel-loaded lipid microsphere with different doses of 0.4, 0.8, and 1.6 mg/kg. The area under the concentration-time curve and the peak concentration of larotaxel seemed to increase with increasing dose proportionally, suggesting linear pharmacokinetics.

  13. Information-dependent acquisition-mediated LC-MS/MS screening procedure with semiquantitative potential.

    Science.gov (United States)

    Decaestecker, Tineke N; Vande Casteele, Sofie R; Wallemacq, Pierre E; Van Peteghem, Carlos H; Defore, Dieter L; Van Bocxlaer, Jan F

    2004-11-01

    The development of a LC-MS/MS general unknown screening procedure for toxicologically relevant substances in blood samples by means of information-dependent acquisition on a Q-TOF is reported. IDA is an artificial intelligence-based product ion scan mode providing automatic "on-the-fly" MS to MS/MS switching. By performing information-dependent scanning at two different fragmentation energies, two collision-induced dissociation product ion spectra for each of the detected compounds are generated. As such, information-rich MS/MS spectra are obtained from precursor ions not known beforehand. In addition, limitation of the MS/MS acquisition time to an acceptable minimum resulted in an almost instantaneous switch back to the MS mode. As such, this approach provided MS chromatograms that still could be of use for semiquantitative purposes. Since the switching intensity threshold, unequivocally related to the background noise, proved a critical parameter, the solid-phase extraction procedure, the liquid chromatographic conditions, and the mass spectrometric parameters all were optimized to the advantage of information-dependent acquisition. Finally, the screening procedure we developed was benchmarked, on one hand, qualitatively against the results obtained from traditional GUS approaches in a number of routine toxicological laboratories (20 samples) and, on the other hand, quantitatively with respect to its potential against established LC-MS/MS methods (7 samples). The procedure performed very well from a qualitative point of view; almost all of the drugs detected by the conventional techniques were identified, as well as additional drugs that were not previously reported. The procedure proved well-suited for an initial semiquantitative assessment, as is customary in, for example, forensic toxicology before accurate intoxication levels are determined using targeted analytical analyses.

  14. Non-enzymolytic adenosine barcode-mediated dual signal amplification strategy for ultrasensitive protein detection using LC-MS/MS.

    Science.gov (United States)

    Yang, Wen; Li, Tengfei; Shu, Chang; Ji, Shunli; Wang, Lei; Wang, Yan; Li, Duo; Mtalimanja, Michael; Sun, Luning; Ding, Li

    2018-05-10

    A method is described for the determination of proteins with LC-MS/MS enabled by a small molecule (adenosine) barcode and based on a double-recognition sandwich structure. The coagulation protein thrombin was chosen as the model analyte. Magnetic nanoparticles were functionalized with aptamer29 (MNP/apt29) and used to capture thrombin from the samples. MNP/apt29 forms a sandwich with functionalized gold nanoparticles modified with (a) aptamer15 acting as thrombin-recognizing element and (b) a large number of adenosine as mass barcodes. The sandwich formed (MNP/apt29-thrombin-apt15/AuNP/adenosine) can ben magnetically separated from the sample. Mass barcodes are subsequently released from the sandwiched structure for further analysis by adding 11-mercaptoundecanoic acid. Adenosine is then detected by LC-MS/MS as it reflects the level of thrombin with impressively amplified signal. Numerous adenosines introduced into the sandwich proportional to the target concentration further amplify the signal. Under optimized conditions, the response is linearly proportional to the thrombin concentration in the range of 0.02 nM to 10 nM, with a detection limit of 9 fM. The application of this method to the determination of thrombin in spiked plasma samples gave recoveries that ranged from 92.3% to 104.7%. Graphical abstract Schematic representation of a method for the determination of thrombin with LC-MS/MS. The method is based on a double-recognition sandwiched structure. With LC-MS/MS, mass barcodes (adenosine) are detected to quantify thrombin, which amplifies the detection signal impressively.

  15. GC-MS Analysis of the Composition of the Essential Oil from Dendranthema indicum Var. Aromaticum Using Three Extraction Methods and Two Columns

    Directory of Open Access Journals (Sweden)

    Sanpeng Fan

    2018-03-01

    Full Text Available Dendranthema indicum var. aromaticum, which is an aromatic plant with a strong and special fragrance throughout the whole plant, is used for the treatment of colds and headaches, and as a mosquito repellant in Shennongjia, Hubei province, China. To analyze the composition of the essential oil from this medicinal herb, we developed a gas chromatography-mass Spectrometry (GC-MS method including microwave-assisted extraction, hydrodistillation and direct headspace analysis in two different stationary phase columns. In total, 115 volatile compounds were identified, of which 90 compounds were identified using Rxi-5MS and 78 using HP-INNOWAX. Our results revealed that the oil was mainly composed of five categories of compound: oxygenated monoterpenes (28.76–78.10%, oxygenated sesquiterpenes (4.27–38.06%, sesquiterpenes (3.22–11.57%, fatty hydrocarbons (1.65–9.81% and monoterpenes (0–3.32%. The major constituents are α-thujone, β-thujone, cis-sabinol, sabinyl acetate and (--neointermedeol.However, the essential oil composition in the published literature differs significantly. Therefore, a cluster analysis was carried out using the top ten compositions in the reported literature as well as this study, using Minitab software. To provide detailed information on plant origin, the ITS1-5.8s-ITS2 region was amplified and sequenced (Accession No. MF668250. Besides, in order to provide a macroscopic view of the chemical composition, the biosynthetic pathway of the main components was summarized according to the Kyoto Encyclopedia of Genes and Genomes (KEGG database and the published literatures.

  16. Evaluation of laser diode thermal desorption-tandem mass spectrometry (LDTD-MS-MS) in forensic toxicology.

    Science.gov (United States)

    Bynum, Nichole D; Moore, Katherine N; Grabenauer, Megan

    2014-10-01

    Many forensic laboratories experience backlogs due to increased drug-related cases. Laser diode thermal desorption (LDTD) has demonstrated its applicability in other scientific areas by providing data comparable with instrumentation, such as liquid chromatography-tandem mass spectrometry, in less time. LDTD-MS-MS was used to validate 48 compounds in drug-free human urine and blood for screening or quantitative analysis. Carryover, interference, limit of detection, limit of quantitation, matrix effect, linearity, precision and accuracy and stability were evaluated. Quantitative analysis indicated that LDTD-MS-MS produced precise and accurate results with the average overall within-run precision in urine and blood represented by a %CV forensic toxicology but before it can be successfully implemented that there are some challenges that must be addressed. Although the advantages of the LDTD system include minimal maintenance and rapid analysis (∼10 s per sample) which makes it ideal for high-throughput forensic laboratories, a major disadvantage is its inability or difficulty analyzing isomers and isobars due to the lack of chromatography without the use of high-resolution MS; therefore, it would be best implemented as a screening technique. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Survey on acrylamide in roasted coffee and barley and in potato crisps sold in Italy by a LC-MS/MS method.

    Science.gov (United States)

    Bertuzzi, Terenzio; Rastelli, Silvia; Mulazzi, Annalisa; Pietri, Amedeo

    2017-12-01

    A survey on the occurrence of acrylamide (AA) in roasted coffee, barley, and potato crisps was carried out using an intra-lab validated liquid chromatography (LC)-MS (mass spectrometry)/MS method. Over the years 2015-2016, 66 samples of coffee, 22 of roasted barley, and 22 of potato crisps were collected from retail outlets in Italy. AA was detected in almost all samples. In roasted coffee, the level exceeded 450 µg kg -1 , the limit recommended by the European Commission (EC), in 36.4% of the samples. In roasted barley, mean contamination was slightly lower than in coffee and no sample exceeded the EC limit of 2000 µg kg -1 . The AA contamination in potato crisps was remarkable. A percentage of 36.4 (n = 8) showed a value higher than the EC limit of 1000 µg kg -1 . Considering the average consumption of coffee and potato crisps by Italian people, AA exposure is significant and should be decreased.

  18. Methods for the Design of Vasomotor Symptom Trials: The MsFLASH Network

    Science.gov (United States)

    Newton, Katherine M.; Carpenter, Janet S.; Guthrie, Katherine A.; Anderson, Garnet L.; Caan, Bette; Cohen, Lee S.; Ensrud, Kristine E.; Freeman, Ellen W.; Joffe, Hadine; Sternfeld, Barbara; Reed, Susan D.; Sherman, Sheryl; Sammel, Mary D.; Kroenke, Kurt; Larson, Joseph C.; LaCroix, Andrea Z.

    2013-01-01

    Objective This report describes the "Menopausal Strategies: Finding Lasting Answers to Symptoms and Health” (MsFLASH) network and methodological issues addressed in designing and implementing vasomotor symptom trials. Methods Established in response to a National Institute of Health request for applications, the network was charged with conducting rapid throughput randomized trials of novel and understudied available interventions postulated to alleviate vasomotor and other menopausal symptoms. Included are descriptions of and rationale for criteria used for interventions and study selection, common eligibility and exclusion criteria, common primary and secondary outcome measures, consideration of placebo response, establishment of a biorepository, trial duration, screening and recruitment, statistical methods, and quality control. All trial designs are presented including: 1) a randomized, double-blind, placebo-controlled clinical trial designed to evaluate effectiveness of the selective serotonin reuptake inhibitor escitalopram in reducing vasomotor symptom frequency and severity; 2) a 2×3 factorial design trial to test three different interventions (yoga, exercise, and omega-3 supplementation) for improvement of vasomotor symptom frequency and bother; and 3) a three-arm comparative efficacy trial of the serotonin-norepinephrine reuptake inhibitor venlafaxine and low-dose oral estradiol versus placebo for reducing vasomotor symptom frequency compared to placebo. The network’s structure and governance are also discussed. Conclusions The methods used and lessons learned in the MsFLASH trials are shared to encourage and support the conduct of similar trials and encourage collaborations with other researchers. PMID:23760428

  19. Analysis of pesticides in fruit, vegetables and cereals using methanolic extraction and detection by LC-MS/MS

    DEFF Research Database (Denmark)

    Granby, Kit; Andersen, Jens Hinge; Christensen, Hanne Bjerre

    2004-01-01

    Abstract: A method for analysing carbamates and other relatively polar pesticides by LC–MS–MS with electrospray ionisation has been developed. The method is based on extraction by ultrasonication using a methanolic ammonium acetate–acetic acid buffer. After centrifugation the samples are filtered...... in Miniprep filter HPLC vials and detected by LC–MS–MS. To compensate for variations in the MS response [13C6]-carbaryl was used as internal standard and matrix-matched pesticide solutions were used as external standards for the quantification. The method has been validated for the matrices apple, avocado...

  20. Taxus ingredients in the red arils of Taxus baccata L. determined by HPLC-MS/MS.

    Science.gov (United States)

    Siegle, Lydia; Pietsch, Jörg

    2018-02-09

    Taxus baccata L. is an evergreen conifer whose plant parts are cardiotoxic. Only the red arils of the berries are described as non-toxic and taxane-free. Extraction and HPLC-MS/MS methods were developed for the investigation of the Taxus compounds 3,5-dimethoxyphenol, 10-deacetylbaccatin III, baccatin III, cephalomannine, taxol A and taxinine M in the red arils of the yew berries. MethodologyA liquid-liquid extraction method for the red arils of the fruits from three yews were developed. An accurate (ESI+) HPLC-MS/MS method was performed for the simultaneous detection and determination of the target compounds in multiple reaction monitoring (MRM) mode. All Taxus agents obtained were detected in the red arils. Highest concentrations were determined for baccatin III and 10-deacetylbaccatin III. The developed quantitative method is reliable and selective and was successfully applied for quantification of selected Taxus ingredients in red arils of Taxus baccata. It was disproved that the red arils of the berries do not contain the selected Taxus compounds. Copyright © 2018 John Wiley & Sons, Ltd.

  1. Profiling LC-DAD-ESI-TOF MS method for the determination of phenolic metabolites from avocado (Persea americana).

    Science.gov (United States)

    Hurtado-Fernández, Elena; Carrasco-Pancorbo, Alegría; Fernández-Gutiérrez, Alberto

    2011-03-23

    A powerful HPLC-DAD-ESI-TOF MS method was established for the efficient identification of the chemical constituents in the methanolic extracts of avocado (Persea americana). Separation and detection conditions were optimized by using a standard mix containing 39 compounds belonging to phenolic acids and different categories of flavonoids, analytes that could be potentially present in the avocado extracts. Optimum LC separation was achieved on a Zorbax Eclipse Plus C18 analytical column (4.6×150 mm, 1.8 μm particle size) by gradient elution with water+acetic acid (0.5%) and acetonitrile as mobile phases, at a flow rate of 1.6 mL/min. The detection was carried out by ultraviolet-visible absorption and ESI-TOF MS. The developed method was applied to the study of 3 different varieties of avocado, and 17 compounds were unequivocally identified with standards. Moreover, around 25 analytes were tentatively identified by taking into account the accuracy and isotopic information provided by TOF MS.

  2. Introducing AAA-MS, a rapid and sensitive method for amino acid analysis using isotope dilution and high-resolution mass spectrometry.

    Science.gov (United States)

    Louwagie, Mathilde; Kieffer-Jaquinod, Sylvie; Dupierris, Véronique; Couté, Yohann; Bruley, Christophe; Garin, Jérôme; Dupuis, Alain; Jaquinod, Michel; Brun, Virginie

    2012-07-06

    Accurate quantification of pure peptides and proteins is essential for biotechnology, clinical chemistry, proteomics, and systems biology. The reference method to quantify peptides and proteins is amino acid analysis (AAA). This consists of an acidic hydrolysis followed by chromatographic separation and spectrophotometric detection of amino acids. Although widely used, this method displays some limitations, in particular the need for large amounts of starting material. Driven by the need to quantify isotope-dilution standards used for absolute quantitative proteomics, particularly stable isotope-labeled (SIL) peptides and PSAQ proteins, we developed a new AAA assay (AAA-MS). This method requires neither derivatization nor chromatographic separation of amino acids. It is based on rapid microwave-assisted acidic hydrolysis followed by high-resolution mass spectrometry analysis of amino acids. Quantification is performed by comparing MS signals from labeled amino acids (SIL peptide- and PSAQ-derived) with those of unlabeled amino acids originating from co-hydrolyzed NIST standard reference materials. For both SIL peptides and PSAQ standards, AAA-MS quantification results were consistent with classical AAA measurements. Compared to AAA assay, AAA-MS was much faster and was 100-fold more sensitive for peptide and protein quantification. Finally, thanks to the development of a labeled protein standard, we also extended AAA-MS analysis to the quantification of unlabeled proteins.

  3. Determination of chlormequat in pig serum and sow milk by LC-MS/MS.

    Science.gov (United States)

    Poulsen, M E; Christensen, H B; Sørensen, M T; Leffers, H; Andersen, J H

    2007-11-01

    Chlormequat is a plant growth regulator widely used on cereals, and there is general concern that it may impair human fertility. A LC-MS/MS method for the analysis of chlormequat in milk and serum was developed and validated in connection with an investigation on the effect of chlormequat on pig reproduction. Validation of the method was based on recovery tests at three spiking levels, determined as double determinations and repeated at least four times. Samples were extracted with methanol-water-acetic acid, centrifuged, filtrated and determined by LC-MS/MS. The mean recoveries were in the range 80-110%, and the LOD was 0.2 ng/g for serum and 0.3 ng/g for milk. The values for repeatability and reproducibility were within 2/3 of the limits given by the Horwitz equation. Samples of pig serum (59) and sow milk (27) were analyzed using the method. Chlormequat was determined in four milk samples in the range of 0.4 ng/g to 1.2 ng/g and in all serum samples in the range of 0.2 ng/g-4.0 ng/g.

  4. In situ liquid-liquid extraction as a sample preparation method for matrix-assisted laser desorption/ionization MS analysis of polypeptide mixtures

    DEFF Research Database (Denmark)

    Kjellström, Sven; Jensen, Ole Nørregaard

    2003-01-01

    A novel liquid-liquid extraction (LLE) procedure was investigated for preparation of peptide and protein samples for matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS). LLE using ethyl acetate as the water-immiscible organic solvent enabled segregation of hydrophobic...... matrix to the organic solvent enhanced the efficiency of the LLE-MALDI MS method for analysis of hydrophobic peptides and proteins. LLE-MALDI MS enabled the detection of the hydrophobic membrane protein bacteriorhodopsin as a component in a simple protein mixture. Peptide mixtures containing...... phosphorylated, glycosylated, or acylated peptides were successfully separated and analyzed by the in situ LLE-MALDI MS technique and demonstrate the potential of this method for enhanced separation and structural analysis of posttranslationally modified peptides in proteomics research....

  5. A validated LC-MS/MS determination method for the illegal food additive rhodamine B: Applications of a pharmacokinetic study in rats.

    Science.gov (United States)

    Cheng, Yung-Yi; Tsai, Tung-Hu

    2016-06-05

    Rhodamine B is an illegal and potentially carcinogenic food dye. The aim of this study was to develop a convenient, rapid, and sensitive UHPLC-MS/MS method for pharmacokinetic studies in rats. Rat plasma samples were deproteinized with acetonitrile and separated by UHPLC on a reverse-phase C18e column (100mm×2.1mm, 2μm) using a mobile phase consisting of methanol-5mM ammonium acetate (90:10, v/v). Detection was performed using a triple quadrupole tandem mass spectrometer in the selected reaction monitoring mode at [M](+) ion m/z 443.39→399.28 for rhodamine B and [M+H](+) ion m/z 253.17→238.02 for 5-methoxyflavone as the internal standard. This method was specific and produced linear results over a concentration range of 0.5-100ng/mL, with a lower limit of quantitation of 0.5ng/mL. All validation parameters, including the inter-day, intra-day, matrix effect, recovery, and stability in rat plasma, were acceptable according to the biological method validation guidelines developed by the FDA (2001). This method was successfully applied to a pharmacokinetic study in rats; oral administration of 1mg/kg of rhodamine B yielded a time to maximum concentration (Tmax) of 1.3±0.4h and an elimination half-life of 8.8±1.4h, with a clearance of 229.7±19.4mL/h/kg. These pharmacokinetic results provide a constructive contribution to our understanding of the absorption mechanism of rhodamine B and support additional food safety evaluations. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. LC-MS-based quantification method for Achyranthes root saponins.

    Science.gov (United States)

    Kawahara, Yuki; Hoshino, Tatsuro; Morimoto, Hidetaka; Shinizu, Tomofumi; Narukawa, Yuji; Fuchino, Hiroyuki; Kawahara, Nobuo; Kiuchi, Fumiyuki

    2016-01-01

    A liquid chromatography mass spectrometry (LC-MS) method was developed for simultaneous quantitative analysis of Achyranthes root saponins: chikusetsusaponins IVa (1) and V (2), achyranthosides B (3), C (4), D (5), E (6), and G (7), sulfachyranthosides B (8) and D (9), and betavulgarosides II (10) and IV (11). Satisfactory separation of the saponins was achieved with the use of a volatile ion-pair reagent (dihexyl ammonium acetate) on a phenyl-hexylated silica gel column, and the amounts of saponins extracted under three different conditions were determined. When Achyranthes root was extracted with water at room temperature, achyranthosides B (3) and D (5) were the major saponins, and smaller amounts of other saponins (4, 6-11) were present. However, the amounts of chikusetsusaponins (1 and 2) were negligible. Under the condition to make a standard decoction of a Kampo formula, the major saponins were achyranthosides B (3), C (4), and D (5), and small amounts of chikusetsusaponins IVa (1) and V (2) appeared, whereas prolonged heating largely increased the amounts of chikusetsusaponins. This method can be used for quality control of Achyranthes root.

  7. An Improved Pansharpening Method for Misaligned Panchromatic and Multispectral Data.

    Science.gov (United States)

    Li, Hui; Jing, Linhai; Tang, Yunwei; Ding, Haifeng

    2018-02-11

    Numerous pansharpening methods were proposed in recent decades for fusing low-spatial-resolution multispectral (MS) images with high-spatial-resolution (HSR) panchromatic (PAN) bands to produce fused HSR MS images, which are widely used in various remote sensing tasks. The effect of misregistration between MS and PAN bands on quality of fused products has gained much attention in recent years. An improved method for misaligned MS and PAN imagery is proposed, through two improvements made on a previously published method named RMI (reduce misalignment impact). The performance of the proposed method was assessed by comparing with some outstanding fusion methods, such as adaptive Gram-Schmidt and generalized Laplacian pyramid. Experimental results show that the improved version can reduce spectral distortions of fused dark pixels and sharpen boundaries between different image objects, as well as obtain similar quality indexes with the original RMI method. In addition, the proposed method was evaluated with respect to its sensitivity to misalignments between MS and PAN bands. It is certified that the proposed method is more robust to misalignments between MS and PAN bands than the other methods.

  8. Investigation of enrofloxacin residues in broiler tissues using ELISA and LC-MS/MS.

    Science.gov (United States)

    Panzenhagen, Pedro Henrique N; Aguiar, Waldemir S; Gouvêa, Raquel; de Oliveira, Andréa M G; Barreto, Fabiano; Pereira, Virgínia L A; Aquino, Maria Helena C

    2016-01-01

    This study investigated the efficiency of an enrofloxacin ELISA test kit to detect the presence of enrofloxacin residues in broiler tissues compared with LC-MS/MS. Broiler tissues from 72 samples consisting of 60 breast muscle, six pools of livers (500 g each) and six pools of kidneys (500 g each) were obtained from six different slaughterhouses. Breast muscle from 10 carcasses and pools of livers and kidneys from approximately 200 carcasses of the same flock were collected from each slaughterhouse. ELISA and HPLC were used to identify and quantify the contamination of the samples with enrofloxacin. A total of 72% of the analysed samples contained enrofloxacin residues detected by the ELISA and 22.2% were detected by LC-MS/MS. The mean values of enrofloxacin contamination found in chicken breast by ELISA and HPLC were 8.63 and 12.25 μg kg(-1), respectively. None of the samples exceeded the maximum limit of 100 μg kg(-1) by both methods set by the European Union as well as the Brazilian Agriculture Ministry. All positive samples for enrofloxacin residues detected by LC-MS/MS were also positive by ELISA. These data confirm the efficiency of the ELISA test, and suggest its use as a screening method for enrofloxacin residues in poultry tissues due to its quick results, low price and ease of applicability.

  9. Determination of chlormequat in pig serum and sow milk by LC-MS/MS

    DEFF Research Database (Denmark)

    Poulsen, Mette Erecius; Christensen, Hanne Bjerre; Sørensen, M.T.

    2007-01-01

    reproduction. Validation of the method was based on recovery tests at three spiking levels, determined as double determinations and repeated at least four times. Samples were extracted with methanol-water-acetic acid, centrifuged, filtrated and determined by LC-MS/MS. The mean recoveries were in the range 80...

  10. Method validation for determination of heavy metals in wine and slightly alcoholic beverages by ICP-MS

    International Nuclear Information System (INIS)

    Voica, Cezara; Dehelean, Adriana; Pamula, A

    2009-01-01

    The Organisation International de la Vigne et du Vin (OIV) fixed an uppermost level for some heavy metals in wine. Consequently, the need to determine very low concentration of elements that may be present in wine in trace and ultra trace levels occurred. Inductively coupled plasma mass spectrometry ICP-MS is considered an excellent tool for detailed characterization of the elementary composition of many samples, including samples of drinks. In this study a method of quantitative analysis for the determination of toxic metals (Cr, As, Cd, Ni, Hg, Pb) in wines and slightly alcoholic beverages by ICP-MS was validated. Several parameters have been taken into account and evaluated for the validation of method, namely: linearity, the minimum detection limit, the limit of quantification, accuracy and uncertainty.

  11. Method validation for determination of heavy metals in wine and slightly alcoholic beverages by ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Voica, Cezara; Dehelean, Adriana; Pamula, A, E-mail: cezara.voica@itim-cj.r [National Institute for Research and Development of Isotopic and Molecular Technologies, 65-103 Donath, 400293 Cluj-Napoca (Romania)

    2009-08-01

    The Organisation International de la Vigne et du Vin (OIV) fixed an uppermost level for some heavy metals in wine. Consequently, the need to determine very low concentration of elements that may be present in wine in trace and ultra trace levels occurred. Inductively coupled plasma mass spectrometry ICP-MS is considered an excellent tool for detailed characterization of the elementary composition of many samples, including samples of drinks. In this study a method of quantitative analysis for the determination of toxic metals (Cr, As, Cd, Ni, Hg, Pb) in wines and slightly alcoholic beverages by ICP-MS was validated. Several parameters have been taken into account and evaluated for the validation of method, namely: linearity, the minimum detection limit, the limit of quantification, accuracy and uncertainty.

  12. Simultaneous determination of creatinine and creatine in human serum by double-spike isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS).

    Science.gov (United States)

    Fernández-Fernández, Mario; Rodríguez-González, Pablo; Añón Álvarez, M Elena; Rodríguez, Felix; Menéndez, Francisco V Álvarez; García Alonso, J Ignacio

    2015-04-07

    This work describes the first multiple spiking isotope dilution procedure for organic compounds using (13)C labeling. A double-spiking isotope dilution method capable of correcting and quantifying the creatine-creatinine interconversion occurring during the analytical determination of both compounds in human serum is presented. The determination of serum creatinine may be affected by the interconversion between creatine and creatinine during sample preparation or by inefficient chemical separation of those compounds by solid phase extraction (SPE). The methodology is based on the use differently labeled (13)C analogues ((13)C1-creatinine and (13)C2-creatine), the measurement of the isotopic distribution of creatine and creatinine by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and the application of multiple linear regression. Five different lyophilized serum-based controls and two certified human serum reference materials (ERM-DA252a and ERM-DA253a) were analyzed to evaluate the accuracy and precision of the proposed double-spike LC-MS/MS method. The methodology was applied to study the creatine-creatinine interconversion during LC-MS/MS and gas chromatography-mass spectrometry (GC-MS) analyses and the separation efficiency of the SPE step required in the traditional gas chromatography-isotope dilution mass spectrometry (GC-IDMS) reference methods employed for the determination of serum creatinine. The analysis of real serum samples by GC-MS showed that creatine-creatinine separation by SPE can be a nonquantitative step that may induce creatinine overestimations up to 28% in samples containing high amounts of creatine. Also, a detectable conversion of creatine into creatinine was observed during sample preparation for LC-MS/MS. The developed double-spike LC-MS/MS improves the current state of the art for the determination of creatinine in human serum by isotope dilution mass spectrometry (IDMS), because corrections are made for all the possible errors

  13. Dynamic changes of flavonoids in Actinidia valvata leaves at different growing stages measured by HPLC-MS/MS.

    Science.gov (United States)

    DU, Qiao-Hui; Zhang, Qiao-Yan; Han, Ting; Jiang, Yi-Ping; Peng, Cheng; Xin, Hai-Liang

    2016-01-01

    Flavonoids are a large group of phenolic secondary metabolites havinga wide range of biochemical and pharmacological effects. Quantitative analysis of flavonoid profiles in the genus Actinidia, which has not been intensively conducted, is useful to a better understanding of the pattern and distribution of flavonoids. In the present work, a liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method was developed to profile the flavonoids, which was then used to determine the dynamic change of 17 biologically active flavonoids in the leaves of Actinidia valvata at the main growing stages, including glucuronides and acylated di- and triglycosides of flavonoids. The contents of flavonoid triglycosides were significantly higher than other flavonoids. The highest concentrations of kaemperol glycosides were observed in June, while other flavonoids showed highest concentrations in October. On the other hand, the contents of four isorhamnetin glycosides were increased sharply in September to October. The flavonoid profiles seem to be related to temperature, UV-B, and water deficit. Further studies are required to examine the functions of flavonoids in the Actinidia valvata and the underlying molecular mechanisms of actions. Copyright © 2016 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.

  14. Origin Discrimination of Osmanthus fragrans var. thunbergii Flowers using GC-MS and UPLC-PDA Combined with Multivariable Analysis Methods.

    Science.gov (United States)

    Zhou, Fei; Zhao, Yajing; Peng, Jiyu; Jiang, Yirong; Li, Maiquan; Jiang, Yuan; Lu, Baiyi

    2017-07-01

    Osmanthus fragrans flowers are used as folk medicine and additives for teas, beverages and foods. The metabolites of O. fragrans flowers from different geographical origins were inconsistent in some extent. Chromatography and mass spectrometry combined with multivariable analysis methods provides an approach for discriminating the origin of O. fragrans flowers. To discriminate the Osmanthus fragrans var. thunbergii flowers from different origins with the identified metabolites. GC-MS and UPLC-PDA were conducted to analyse the metabolites in O. fragrans var. thunbergii flowers (in total 150 samples). Principal component analysis (PCA), soft independent modelling of class analogy analysis (SIMCA) and random forest (RF) analysis were applied to group the GC-MS and UPLC-PDA data. GC-MS identified 32 compounds common to all samples while UPLC-PDA/QTOF-MS identified 16 common compounds. PCA of the UPLC-PDA data generated a better clustering than PCA of the GC-MS data. Ten metabolites (six from GC-MS and four from UPLC-PDA) were selected as effective compounds for discrimination by PCA loadings. SIMCA and RF analysis were used to build classification models, and the RF model, based on the four effective compounds (caffeic acid derivative, acteoside, ligustroside and compound 15), yielded better results with the classification rate of 100% in the calibration set and 97.8% in the prediction set. GC-MS and UPLC-PDA combined with multivariable analysis methods can discriminate the origin of Osmanthus fragrans var. thunbergii flowers. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  15. Evaluation of the Effects of Ketoconazole and Voriconazole on the Pharmacokinetics of Oxcarbazepine and Its Main Metabolite MHD in Rats by UPLC-MS-MS.

    Science.gov (United States)

    Chen, Xinxin; Gu, Ermin; Wang, Shuanghu; Zheng, Xiang; Chen, Mengchun; Wang, Li; Hu, Guoxin; Cai, Jian-ping; Zhou, Hongyu

    2016-03-01

    Oxcarbazepine (OXC), a second-generation antiepileptic drug, undergoes rapid reduction with formation of the active metabolite 10,11-dihydro-10-hydroxy-carbazepine (MHD) in vivo. In this study, a method for simultaneous determination of OXC and MHD in rat plasma using ultra-performance liquid chromatography with tandem mass spectrometry (UPLC-MS-MS) was developed and validated. Under given chromatographic conditions, OXC, MHD and internal standard diazepam were separated well and quantified by electrospray positive ionization mass spectrometry in the multiple reaction monitoring transitions mode. The method validation demonstrated good linearity over the range of 10-2,000 ng/mL for OXC and 5-1,000 ng/mL for MHD. The lower limit of quantification was 5 ng/mL for OXC and 2.5 ng/mL for MHD, respectively. The method was successfully applied to the evaluation of the pharmacokinetics of OXC and MHD in rats, with or without pretreatment by ketoconazole (KET) and voriconazole (VOR). Statistics indicated that KET and VOR significantly affected the disposition of OXC and MHD in vivo, whereas VOR predominantly interfered with the disposition of MHD. This method is suitable for pharmacokinetic study in small animals. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Preclinical pharmacokinetic evaluation and metabolites identification of methyl salicylate-2-O-β-d-lactoside in rats using LC-MS/MS and Q-TOF-MS methods.

    Science.gov (United States)

    Zhang, Dan; Huang, Chao; Xin, Wenyu; Ma, Xiaowei; Zhang, Weiku; Zhang, Tiantai; Du, Guanhua

    2015-05-10

    Methyl salicylate-2-O-β-d-lactoside (MSL) is a natural salicylate derivative from the traditional Chinese medicine of Gaultheria yunnanensis (Franch.) Rehder (G. yunnanensis). As a non-steroidal anti-inflammatory drug (NSAID), MSL exerts a significant anti-arthritis effect but hardly has any gastrointestinal toxicity. In this paper, the pharmacokinetics, distribution, excretion and identification of MSL and its metabolites are described following rat oral and intravenous administration. The biological samples were quantified by UPLC-MS/MS and the metabolites in urine and feces were identified by using Q-TOF-MS. These results will support future investigations leading to clinical development of this drug. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Interleukin-37 expression and its potential role in oral leukoplakia and oral squamous cell carcinoma.

    Science.gov (United States)

    Lin, Lin; Wang, Jiayi; Liu, Dongjuan; Liu, Sai; Xu, Hao; Ji, Ning; Zhou, Min; Zeng, Xin; Zhang, Dunfang; Li, Jing; Chen, Qianming

    2016-05-26

    Interleukin 37 (IL-37) has been reported to play a significant role in innate immune response and to be involved in several kinds of cancers. However, the investigation of association between IL-37 and oral mucosa carcinogenesis hasn't been clearly established. The aim of the study was to assess IL-37 expression and explore its role in oral mucosa carcinogenesis. The expression of IL-37 increased from normal control (NC) to Oral leukoplakia (OLK) and oral squamous cell carcinoma (OSCC). Moreover, statistically highly significant difference was present between scores of OLK with and without mild/moderate dysplasia (P oral mucosa carcinogenesis. Overall, IL-37 can be used as a biomarker for early oral tumorigenesis and for malignant transformation risk assessment of premalignant lesions.

  18. X-ray photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Attekum, P.M.T.M. van.

    1979-01-01

    The methods and results of X-ray photoelectron spectroscopy in the study of plasmons, alloys and gold compounds are discussed. After a comprehensive introduction, seven papers by the author, previously published elsewhere, are reprinted and these cover a wide range of the uses of X-ray photoelectron spectroscopy. (W.D.L.)

  19. Development and validation of a liquid chromatography-MS/MS method for simultaneous quantification of tenofovir and efavirenz in biological tissues and fluids.

    Science.gov (United States)

    Barreiros, Luisa; Cunha-Reis, Cassilda; Silva, Eduarda M P; Carvalho, Joana R B; das Neves, José; Sarmento, Bruno; Segundo, Marcela A

    2017-03-20

    Millions of people worldwide live with human immunodeficiency virus (HIV) infection thus justifying the continuous search for new prevention and treatment strategies, including topical microbicide products combining antiretroviral drugs (ARVs) such as tenofovir (TFV) and efavirenz (EFV). Therefore, the aim of this work was to develop and validate a high performance liquid chromatography method coupled to triple quadrupole-tandem mass spectrometry (HPLC-MS/MS) for the quantification of TFV and EFV in biological matrices (mouse vaginal tissue, vaginal lavage and blood plasma). Chromatographic separation was achieved using a reversed phase C18 column (3μm, 100×2.1mm) at 45°C and elution in gradient mode using a combination of 0.1% (v/v) formic acid in water and 0.1% (v/v) formic acid in acetonitrile at 0.35mLmin -1 . Total run time was 9min, with retention time of 2.8 and 4.1min for TFV and EFV, respectively. The MS was operated in positive ionization mode (ESI+) for TFV and in negative ionization mode (ESI-) for EFV detection. Data were acquired in selected reaction monitoring (SRM) mode and deuterated ARVs were employed as internal standards. Calibration curves were linear for ARV concentrations ranging from 4 to 500ngmL -1 with LOD and LOQ for both analytes ≤0.4 and ≤0.7ngmL -1 in sample extracts, respectively. The method was found to be specific, accurate (96.0-106.0% of nominal values) and precise (RSDfluids were ≥88.4%. Matrix effects were observed for EFV determination in tissue and plasma extracts but compensated by the use of deuterated internal standards. The proposed methodology was successfully applied to a pharmacokinetic study following intravaginal administration of both ARVs. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Quantification of acetaminophen (paracetamol) in human plasma and urine by stable isotope-dilution GC-MS and GC-MS/MS as pentafluorobenzyl ether derivative.

    Science.gov (United States)

    Trettin, Arne; Zoerner, Alexander A; Böhmer, Anke; Gutzki, Frank-Mathias; Stichtenoth, Dirk O; Jordan, Jens; Tsikas, Dimitrios

    2011-08-01

    We report on the quantitative determination of acetaminophen (paracetamol; NAPAP-d(0)) in human plasma and urine by GC-MS and GC-MS/MS in the electron-capture negative-ion chemical ionization (ECNICI) mode after derivatization with pentafluorobenzyl (PFB) bromide (PFB-Br). Commercially available tetradeuterated acetaminophen (NAPAP-d(4)) was used as the internal standard. NAPAP-d(0) and NAPAP-d(4) were extracted from 100-μL aliquots of plasma and urine with 300 μL ethyl acetate (EA) by vortexing (60s). After centrifugation the EA phase was collected, the solvent was removed under a stream of nitrogen gas, and the residue was reconstituted in acetonitrile (MeCN, 100 μL). PFB-Br (10 μL, 30 vol% in MeCN) and N,N-diisopropylethylamine (10 μL) were added and the mixture was incubated for 60 min at 30 °C. Then, solvents and reagents were removed under nitrogen and the residue was taken up with 1000 μL of toluene, from which 1-μL aliquots were injected in the splitless mode. GC-MS quantification was performed by selected-ion monitoring ions due to [M-PFB](-) and [M-PFB-H](-), m/z 150 and m/z 149 for NAPAP-d(0) and m/z 154 and m/z 153 for NAPAP-d(4), respectively. GC-MS/MS quantification was performed by selected-reaction monitoring the transition m/z 150 → m/z 107 and m/z 149 → m/z 134 for NAPAP-d(0) and m/z 154 → m/z 111 and m/z 153 → m/z 138 for NAPAP-d(4). The method was validated for human plasma (range, 0-130 μM NAPAP-d(0)) and urine (range, 0-1300 μM NAPAP-d(0)). Accuracy (recovery, %) ranged between 89 and 119%, and imprecision (RSD, %) was below 19% in these matrices and ranges. A close correlation (r>0.999) was found between the concentrations measured by GC-MS and GC-MS/MS. By this method, acetaminophen can be reliably quantified in small plasma and urine sample volumes (e.g., 10 μL). The analytical performance of the method makes it especially useful in pediatrics. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Profiling the Oxylipin and Endocannabinoid Metabolome by UPLC-ESI-MS/MS in Human Plasma to Monitor Postprandial Inflammation.

    Science.gov (United States)

    Gouveia-Figueira, Sandra; Späth, Jana; Zivkovic, Angela M; Nording, Malin L

    2015-01-01

    Bioactive lipids, including oxylipins, endocannabinoids, and related compounds may function as specific biochemical markers of certain aspects of inflammation. However, the postprandial responsiveness of these compounds is largely unknown; therefore, changes in the circulating oxylipin and endocannabinoid metabolome in response to a challenge meal were investigated at six occasions in a subject who freely modified her usual diet. The dietary change, and especially the challenge meal itself, represented a modification of precursor fatty acid status, with expectedly subtle effects on bioactive lipid levels. To detect even the slightest alteration, highly sensitive ultra-performance liquid chromatography (UPLC) coupled to electrospray ionization (ESI) tandem mass spectrometry (MS/MS) methods for bioactive lipid profiling was employed. A previously validated UPLC-ESI-MS/MS method for profiling the endocannabinoid metabolome was used, while validation of an UPLC-ESI-MS/MS method for oxylipin analysis was performed with acceptable outcomes for a majority of the parameters according to the US Food and Drug Administration guidelines for linearity (0.9938 metabolome, caused by changes in diet and ii) responsiveness to a challenge meal for a subset of the oxylipin and endocannabinoid metabolome. To summarize, we have shown proof-of-concept of our UPLC-ESI-MS/MS bioactive lipid protocols for the purpose of monitoring subtle shifts, and thereby useful to address lipid-mediated postprandial inflammation.

  2. Importance of MS selectivity and chromatographic separation in LC-MS/MS-based methods when investigating pharmaceutical metabolites in water. Dipyrone as a case of study.

    Science.gov (United States)

    Ibáñez, M; Gracia-Lor, E; Sancho, J V; Hernández, F

    2012-08-01

    Pharmaceuticals are emerging contaminants of increasing concern because of their presence in the aquatic environment and potential to reach drinking-water sources. After human and/or veterinary consumption, pharmaceuticals can be excreted in unchanged form, as the parent compound, and/or as free or conjugated metabolites. Determination of most pharmaceuticals and metabolites in the environment is commonly made by liquid chromatography (LC) coupled to mass spectrometry (MS). LC coupled to tandem MS is the technique of choice nowadays in this field. The acquisition of two selected reaction monitoring (SRM) transitions together with the retention time is the most widely accepted criterion for a safe quantification and confirmation assay. However, scarce attention is normally paid to the selectivity of the selected transitions as well as to the chromatographic separation. In this work, the importance of full spectrum acquisition high-resolution MS data using a hybrid quadrupole time-of-flight analyser and/or a suitable chromatographic separation (to reduce the possibility of co-eluting interferences) is highlighted when investigating pharmaceutical metabolites that share common fragment ions. For this purpose, the analytical challenge associated to the determination of metabolites of the widely used analgesic dipyrone (also known as metamizol) in urban wastewater is discussed. Examples are given on the possibilities of reporting false positives of dypirone metabolites by LC-MS/MS under SRM mode due to a wrong assignment of identity of the compounds detected. Copyright © 2012 John Wiley & Sons, Ltd.

  3. Establishment of a method for determination of arsenic species in seafood by LC-ICP-MS.

    Science.gov (United States)

    Zmozinski, Ariane V; Llorente-Mirandes, Toni; López-Sánchez, José F; da Silva, Márcia M

    2015-04-15

    An analytical method for determination of arsenic species (inorganic arsenic (iAs), methylarsonic acid (MA), dimethylarsinic acid (DMA), arsenobetaine (AB), trimethylarsine oxide (TMAO) and arsenocholine (AC)) in Brazilian and Spanish seafood samples is reported. This study was focused on extraction and quantification of inorganic arsenic (iAs), the most toxic form. Arsenic speciation was carried out via LC with both anionic and cationic exchange with ICP-MS detection (LC-ICP-MS). The detection limits (LODs), quantification limits (LOQs), precision and accuracy for arsenic species were established. The proposed method was evaluated using eight reference materials (RMs). Arsenobetaine was the main species found in all samples. The total and iAs concentration in 22 seafood samples and RMs ranged between 0.27-35.2 and 0.02-0.71 mg As kg(-1), respectively. Recoveries ranging from 100% to 106% for iAs, based on spikes, were achieved. The proposed method provides reliable iAs data for future risk assessment analysis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Qualitative analysis of MDR-reversing Anastasia Black (Russian black sweet pepper, Capsicum annuum, Solanaceae) extracts and fractions by HPLC and LC-MS-MS methods.

    Science.gov (United States)

    Schelz, Zsuzsanna; Molnár, Joseph; Fogliano, Vincenzo; Ferracane, Rosalia; Pernice, Rita; Shirataki, Yoshiaki; Motohashi, Noboru

    2006-01-01

    In earlier experiments, the MDR (multidrug resistance)-reversal activities of Anastasia Black (Russian black sweet pepper) extracts had been analysed. Recently, the most effective MDR reversing extracts and fractions have been separated by HPLC (high-performance liquid chromatography, for carotenoids) and LC-MS-MS (HPLC combined with mass spectrometry, for phenolic compounds) methods. As a result of the analytical studies, the following flavonoids had been identified: feruloyl glucopyranoside, quercetin rhamnopyranoside glucopyranoside, luteolin glucopyranoside arabinopyranoside, apigenin glucopyranoside arabinopyranoside, quercetin rhamnopyranoside, luteolin arabinopyranoside diglucopy-ranoside, hesperidine and luteolin glucuronide. According to the literature, the aglycones of these phenolic compounds exhibit MDR-reversal activity in vitro, and the connection between the phenolic content of Anastasia Black and MDR-reversal action was therefore studied by different analytical methods. The results of this study revealed that the identified flavonoids of Anastasia Black may be only partially responsible for the modulation of the MDR of mouse lymphoma cells. Other lipophilic compounds, most probably carotenoids, present in Russian black sweet pepper may act as inhibitors of MDR reversal.

  5. Development and validation of a high throughput LC–MS/MS method for simultaneous quantitation of pioglitazone and telmisartan in rat plasma and its application to a pharmacokinetic study

    Directory of Open Access Journals (Sweden)

    Pinaki Sengupta

    2017-12-01

    Full Text Available Management of cardiovascular risk factors in diabetes demands special attention due to their co-existence. Pioglitazone (PIO and telmisartan (TLM combination can be beneficial in effective control of cardiovascular complication in diabetes. In this research, we developed and validated a high throughput LC–MS/MS method for simultaneous quantitation of PIO and TLM in rat plasma. This developed method is more sensitive and can quantitate the analytes in relatively shorter period of time compared to the previously reported methods for their individual quantification. Moreover, till date, there is no bioanalytical method available to simultaneously quantitate PIO and TLM in a single run. The method was validated according to the USFDA guidelines for bioanalytical method validation. A linear response of the analytes was observed over the range of 0.005–10 µg/mL with satisfactory precision and accuracy. Accuracy at four quality control levels was within 94.27%–106.10%. The intra- and inter-day precision ranged from 2.32%–10.14 and 5.02%–8.12%, respectively. The method was reproducible and sensitive enough to quantitate PIO and TLM in rat plasma samples of a preclinical pharmacokinetic study. Due to the potential of PIO-TLM combination to be therapeutically explored, this method is expected to have significant usefulness in future. Keywords: LC–MS/MS, Rat plasma, Pharmacokinetic applicability, Telmisartan, Pioglitazone, Pharmacokinetic application

  6. Realisatie van Excel Kwadraat in de praktijk

    NARCIS (Netherlands)

    Dijkstra, Elma

    2013-01-01

    Dijkstra, E. M. (2013, 2 July). Realisatie van Excel Kwadraat in de praktijk [Realization of Excellent Education in practice]. Presentation held at the OLK-meeting, ITS, Radboud University, Nijmegen, The Netherlands.

  7. Development of an LC–MS/MS method for the quantitation of deoxyglycychloxazol in rat plasma and its application in pharmacokinetic study

    Directory of Open Access Journals (Sweden)

    Rongshan Li

    2016-06-01

    Full Text Available Deoxyglycychloxazol (TY501 is a glycyrrhetinic acid derivative which exhibits high anti-inflammatory activity and reduced pseudoaldosteronism compared to glycyrrhetinic acid. In this study, a sensitive and rapid liquid chromatography–tandem mass spectrometry (LC–MS/MS method was established for the quantitation of TY501 in rat plasma. Plasma samples were treated by precipitating protein with methanol and supernatants were separated by a Symmetry C8 column with the mobile phase consisting of methanol and 10 mM ammonium formate (containing 0.1% of formic acid (90:10, v/v. The selected reaction monitoring (SRM transitions were performed at m/z 647.4→191.2 for TY501 and m/z 473.3→143.3 for astragaloside aglycone (IS in the positive ion mode with atmospheric pressure chemical ionization (APCI source. Calibration curve was linear over the concentration range of 5–5000 ng/mL. The lower limit of quantification was 5 ng/mL. The mean recovery was over 88%. The intra- and inter-day precisions were lower than 6.0% and 12.8%, respectively, and the accuracy was within ±1.3%. TY501 was stable under usual storage conditions and handling procedure. The validated method has been successfully applied to a pharmacokinetic study after oral administration of TY501 to rats at a dosage of 10 mg/kg.

  8. Method for reducing x-ray background signals from insertion device x-ray beam position monitors

    Directory of Open Access Journals (Sweden)

    Glenn Decker

    1999-11-01

    Full Text Available A method is described that provides a solution to the long-standing problem of stray radiation-induced signals on photoemission-based x-ray beam position monitors (BPMs located on insertion device x-ray beam lines. The method involves the introduction of a chicane into the accelerator lattice that directs unwanted x radiation away from the photosensitive x-ray BPM blades. This technique has been implemented at the Advanced Photon Source, and experimental confirmation of the technique is provided.

  9. Consensus recommendations for MS cortical lesion scoring using double inversion recovery MRI

    DEFF Research Database (Denmark)

    Geurts, J J G; Roosendaal, S D; Calabrese, M

    2011-01-01

    Different double inversion recovery (DIR) sequences are currently used in multiple sclerosis (MS) research centers to visualize cortical lesions, making it difficult to compare published data. This study aimed to formulate consensus recommendations for scoring cortical lesions in patients with MS...

  10. The potential use of complex derivatization procedures in comprehensive HPLC-MS/MS detection of anabolic steroids.

    Science.gov (United States)

    Baranov, Pavel A; Appolonova, Svetlana A; Rodchenkov, Grigory M

    2010-10-01

    The use of two separate derivatization procedures with the formation of oxime (hydroxyl ammonium pretreatment) and picolinoyl (mixed anhydride method) derivates of anabolic steroids following HPLC-MS/MS analysis was proposed. The main product ions of obtained derivatives for 21 anabolic steroids were evaluated and fragmentation pathways were compared.The analysis of MS/MS spectra for underivatized steroids versus oxime or picolinoyl derivatives showed that in case of analytes containing conjugated double bonds in sterane core all of the observed MS/MS spectra contained abundant product ions of diagnostic value. The implementation of derivatization procedures to such compounds is useful for upgrading sensitivity or selectivity of the evaluated method. On the other hand, MS/MS spectra of underivatized and oxime analytes without conjugated double bonds in sterane core produce spectra with large amounts of low abundant product ions. Picolinoyl derivatives formation leads to highly specific spectra with product ions of diagnostic value coupled with sensitive and selective analysis at the same time. The intra- and inter-group comparison analysis revealed that fragmentation pathways for underivatized steroids and correspondent oxime derivatives are similar.The obtained oxime and picolinoyl derivatives provided 10-15 times higher ESI response in the HPLC-ESI-MS-selected reaction monitoring (SRM) when compared to those of underivatized molecules in positive HPLC-ESI-MS mode.Due to the laborious sample preparation we suggest to use the performed strategy for confirmation analysis purposes, metabolic studies or while the identification of new steroids or steroid-like substances. Copyright © 2010 John Wiley & Sons, Ltd.

  11. Quantitative analysis of 39 polybrominated diphenyl ethers by isotope dilution GC/low-resolution MS.

    Science.gov (United States)

    Ackerman, Luke K; Wilson, Glenn R; Simonich, Staci L

    2005-04-01

    A GC/low-resolution MS method for the quantitative isotope dilution analysis of 39 mono- to heptabrominated diphenyl ethers was developed. The effects of two different ionization sources, electron impact (EI) and electron capture negative ionization (ECNI), and the effects of their parameters on production of high-mass fragment ions [M - xH - yBr](-) specific to PBDEs were investigated. Electron energy, emission current, source temperature, ECNI system pressure, and choice of ECNI reagent gases were optimized. Previously unidentified enhancement of PBDE high-mass fragment ion [M - xH - yBr](-) abundance was achieved. Electron energy had the largest impact on PBDE high-mass fragment ion abundance for both the ECNI and EI sources. By monitoring high-mass fragment ions of PBDEs under optimized ECNI source conditions, quantitative isotope dilution analysis of 39 PBDEs was conducted using nine (13)C(12) labeled PBDEs on a low-resolution MS with low picogram to femtogram instrument detection limits.

  12. MS Based Metabonomics

    Energy Technology Data Exchange (ETDEWEB)

    Want, Elizabeth J.; Metz, Thomas O.

    2010-03-01

    1. Gas chromatography-(GC)-MS was the most commonly used MS-based method for small molecule analysis in the 1970s and 1980s. It is still used today for the detection of many metabolic disorders and plays a strong role in plant metabonomics. Liquid chromatography (LC)-MS approaches have grown in popularity for metabolite studies, due to simpler sample preparation, reduced analysis times through the introduction of ultra-high performance liquid chromatography (UPLC)-MS and the ability to observe a wider range of metabolites. This chapter will discuss the role of MS in metabonomics, the techniques involved in this exciting area, and the current and future applications of the field. The various bioinformatics tools and multivariate analysis techniques used to maximize information recovery and to aid in the interpretation of the very large data sets typically obtained in metabonomics studies will also be discussed. While there are many different MS-based approaches utilized in metabonomics studies, emphasis will be placed on more established methods.

  13. Combined analysis of 1,3-benzodioxoles by crystalline sponge X-ray crystallography and laser desorption ionization mass spectrometry.

    Science.gov (United States)

    Hayashi, Yukako; Ohara, Kazuaki; Taki, Rika; Saeki, Tomomi; Yamaguchi, Kentaro

    2018-03-12

    The crystalline sponge (CS) method, which employs single-crystal X-ray diffraction to determine the structure of an analyte present as a liquid or an oil and having a low melting point, was used in combination with laser desorption ionization mass spectrometry (LDI-MS). 1,3-Benzodioxole derivatives were encapsulated in CS and their structures were determined by combining X-ray crystallography and MS. After the X-ray analysis, the CS was subjected to imaging mass spectrometry (IMS) with an LDI spiral-time-of-flight mass spectrometer (TOF-MS). The ion detection area matched the microscopic image of the encapsulated CS. In addition, the accumulated 1D mass spectra showed that fragmentation of the guest molecule (hereafter, guest) can be easily visualized without any interference from the fragment ions of CS except for two strong ion peaks derived from the tridentate ligand TPT (2,4,6-tris(4-pyridyl)-1,3,5-triazine) of the CS and its fragment. X-ray analysis clearly showed the presence of the guest as well as the π-π, CH-halogen, and CH-O interactions between the guest and the CS framework. However, some guests remained randomly diffused in the nanopores of CS. In addition, the detection limit was less than sub-pmol order based on the weight and density of CS determined by X-ray analysis. Spectroscopic data, such as UV-vis and NMR, also supported the encapsulation of the guest through the interaction between the guest and CS components. The results denote that the CS-LDI-MS method, which combines CS, X-ray analysis and LDI-MS, is effective for structure determination.

  14. The influence of culture conditions on the identification of Mycobacterium species by MALDI-TOF MS profiling.

    Science.gov (United States)

    Balážová, Tereza; Makovcová, Jitka; Šedo, Ondrej; Slaný, Michal; Faldyna, Martin; Zdráhal, Zbyněk

    2014-04-01

    Matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) represents a simple reliable approach for rapid bacterial identification based on specific peptide/protein fingerprints. However, cell-wall characteristics of mycobacterial species, and their well known stability, complicate MALDI-TOF MS profiling analysis. In this study, we tested two recently published protocols for inactivation and disruption of mycobacteria, and we also examined the influence of different culture conditions (four culture media and five cultivation times) on mass spectral quality and the discriminatory power of the method. We found a significant influence of sample pretreatment method and culture medium on species identification and differentiation for a total of 10 strains belonging to Mycobacterium phlei and Mycobacterium smegmatis. Optimum culture conditions yielding the highest identification success rate against the BioTyper database (Bruker Daltonics) and permitting the possibility of automatic acquisition of mass spectra were found to be distinct for the two mycobacterial species examined. Similarly, individual changes in growth conditions had diverse effects on the two species. For these reasons, thorough control over cultivation conditions should always be employed to maximize the performance and discriminatory power of MALDI-TOF MS profiling, and cultivation conditions must be optimized separately for individual groups of mycobacterial species/strains. © 2014 Federation of European Microbiological Societies. Published by John Wiley & Sons Ltd. All rights reserved.

  15. Multiclass determination and confirmation of antibiotic residues in honey using LC-MS/MS.

    Science.gov (United States)

    Lopez, Mayda I; Pettis, Jeffery S; Smith, I Barton; Chu, Pak-Sin

    2008-03-12

    A multiclass method has been developed for the determination and confirmation in honey of tetracyclines (chlortetracycline, doxycycline, oxytetracycline, and tetracycline), fluoroquinolones (ciprofloxacin, danofloxacin, difloxacin, enrofloxacin, and sarafloxacin), macrolides (tylosin), lincosamides (lincomycin), aminoglycosides (streptomycin), sulfonamides (sulfathiazole), phenicols (chloramphenicol), and fumagillin residues using liquid chromatography tandem mass spectrometry (LC-MS/MS). Erythromycin (a macrolide) and monensin (an ionophore) can be detected and confirmed but not quantitated. Honey samples (approximately 2 g) are dissolved in 10 mL of water and centrifuged. An aliquot of the supernatant is used to determine streptomycin. The remaining supernatant is filtered through a fine-mesh nylon fabric and cleaned up by solid phase extraction. After solvent evaporation and sample reconstitution, 15 antibiotics are assayed by LC-MS/MS using electrospray ionization (ESI) in positive ion mode. Afterward, chloramphenicol is assayed using ESI in negative ion mode. The method has been validated at the low part per billion levels for most of the drugs with accuracies between 65 and 104% and coefficients of variation less than 17%. The evaluation of matrix effects caused by honey of different floral origin is presented.

  16. [Syndrome X vs metabolic syndrome].

    Science.gov (United States)

    Morales Villegas, Enrique

    2006-01-01

    Himsworth in 1939 postulated that Diabetes Mellitus type 2 (DM2) was not only an insulin deficiency state but also a cellular insulin insensitivity disease. Thirty years later, DeFronzo and Reaven demonstrated that insulin resistance (IR) preceded and predisposed for DM2 and atherosclerotic-cardiovascular-disease (ACVD). Reaven was the first to point out the relationship between IR and with hyperglycemia, dyslipidosis, and hypertension as mediators for ACVD, creating the concept of Syndrome X (SX) in 1988. WHO and, thereafter, other medical societies and medical groups, mainly ATP-III, in 2002, based on the difficulty of diagnosing IR in a simple, reliable, and inexpensive way, proposed and published the Metabolic Syndrome (MS) concept, as a group of five variables, i.e., obesity, hyperglycemia, hypertriglyceridemia, low HDL, and hypertension, as an easy clinical approximation to suspect and treat an increased cardiometabolic risk. Nowadays, there are deep and extensive controversies on this issue; however, these controversies do not really exist since all discordant points of view are rather quantitative and not qualitative in nature. This article is aimed at differentiating and harmonizing the complementary concepts of SX and MS, at analyzing why MS is a good "clinical window" to look for IR and its underlying manifestations, and finally to accept that the MS concept complements, but does not substitute or antagonize, traditional scales used to asses cardiovascular risk, such as the Framingham scale.

  17. Feasibility study on X-ray source with pinhole imaging method

    International Nuclear Information System (INIS)

    Qiu Rui; Li Junli

    2007-01-01

    In order to verify the feasibility of study on X-ray source with pinhole imaging method, and optimize the design of X-ray pinhole imaging system, an X-ray pinhole imaging equipment was set up. The change of image due to the change of the position and intensity of X-ray source was estimated with mathematical method and validated with experiment. The results show that the change of the spot position and gray of the spot is linearly related with the change of the position and intensity of X-ray source, so it is feasible to study X-ray source with pinhole imaging method in this application. The results provide some references for the design of X-ray pinhole imaging system. (authors)

  18. Comparison of LC-ESI-MS and GC-MS for the Analysis of a Synthetic Tabun Sample

    National Research Council Canada - National Science Library

    D'Agostino, Paul

    2003-01-01

    Packed capillary LC-ESI-MS and capillary column GC-MS were compared for the analysis of a synthetic tabun sample as each method has advantages for the analysis of samples containing chemical warfare...

  19. Development of a Direct Headspace Collection Method from Arabidopsis Seedlings Using HS-SPME-GC-TOF-MS Analysis

    Directory of Open Access Journals (Sweden)

    Kazuki Saito

    2013-04-01

    Full Text Available Plants produce various volatile organic compounds (VOCs, which are thought to be a crucial factor in their interactions with harmful insects, plants and animals. Composition of VOCs may differ when plants are grown under different nutrient conditions, i.e., macronutrient-deficient conditions. However, in plants, relationships between macronutrient assimilation and VOC composition remain unclear. In order to identify the kinds of VOCs that can be emitted when plants are grown under various environmental conditions, we established a conventional method for VOC profiling in Arabidopsis thaliana (Arabidopsis involving headspace-solid-phase microextraction-gas chromatography-time-of-flight-mass spectrometry (HS-SPME-GC-TOF-MS. We grew Arabidopsis seedlings in an HS vial to directly perform HS analysis. To maximize the analytical performance of VOCs, we optimized the extraction method and the analytical conditions of HP-SPME-GC-TOF-MS. Using the optimized method, we conducted VOC profiling of Arabidopsis seedlings, which were grown under two different nutrition conditions, nutrition-rich and nutrition-deficient conditions. The VOC profiles clearly showed a distinct pattern with respect to each condition. This study suggests that HS-SPME-GC-TOF-MS analysis has immense potential to detect changes in the levels of VOCs in not only Arabidopsis, but other plants grown under various environmental conditions.

  20. UPLC-MS/MS determination of ptaquiloside and pterosin B in preserved natural water.

    Science.gov (United States)

    Clauson-Kaas, Frederik; Hansen, Hans Christian Bruun; Strobel, Bjarne W

    2016-11-01

    The naturally occurring carcinogen ptaquiloside and its degradation product pterosin B are found in water leaching from bracken stands. The objective of this work is to present a new sample preservation method and a fast UPLC-MS/MS method for quantification of ptaquiloside and pterosin B in environmental water samples, employing a novel internal standard. A faster, reliable, and efficient method was developed for isolation of high purity ptaquiloside and pterosin B from plant material for use as analytical standards, with purity verified by 1 H-NMR. The chemical analysis was performed by cleanup and preconcentration of samples with solid phase extraction, before analyte quantification with UPLC-MS/MS. By including gradient elution and optimizing the liquid chromatography mobile phase buffer system, a total run cycle of 5 min was achieved, with method detection limits, including preconcentration, of 8 and 4 ng/L for ptaquiloside and pterosin B, respectively. The use of loganin as internal standard improved repeatability of the determination of both analytes, though it could not be employed for sample preparation. Buffering raw water samples in situ with ammonium acetate to pH ∼5.5 decisively increased sample integrity at realistic transportation and storing conditions prior to extraction. Groundwater samples collected in November 2015 at the shallow water table below a Danish bracken stand were preserved and analyzed using the above methods, and PTA concentrations of 3.8 ± 0.24 μg/L (±sd, n = 3) were found, much higher than previously reported. Graphical abstract Workflow overview of ptaquiloside determination.

  1. X-ray absorption near-edge spectroscopic study of nickel catalysts

    International Nuclear Information System (INIS)

    Soldatov, Alexander V.; Smolentsev, Grigory; Kravtsova, Antonina; Yalovega, Galina; Feiters, Martin C.; Metselaar, Gerald A.; Joly, Yves

    2006-01-01

    Ni-isocyanide and Ni-acac complexes have been studied by X-ray absorption spectroscopy. Theoretical analysis has been done using self-consistent full multiple scattering (MS) approach within both muffin-tin (MT) model of the potential and non-MT finite deference method. For the isocyanide complex, it was shown that MS theoretical spectra reproduce all structural details of the X-ray absorption near-edge structure (XANES), but also that it is important to consider the non-MT effects in the potential for a correct simulation of the shape of the pre-edge structures. The contribution of a non-constant potential in the interstitial regions is extremely important for the interpretation of the XANES of Ni(acac) 2

  2. Development and validation of an UFLC-MS/MS method for enantioselectivity determination of d,l-thero-methylphenidate, d,l-thero-ethylphenidate and d,l-thero-ritalinic acid in rat plasma and its application to pharmacokinetic study.

    Science.gov (United States)

    Zhang, Chenghao; Luo, Huafei; Wu, Yubo; Zhang, Junyun; Zhang, Furong; Lin, Guobei; Wang, Hao

    2016-02-01

    A chiral UFLC-MS/MS method was established and validated for quantifying d-threo-methylphenidate (d-threo-MPH), l-threo-methylphenidate (l-threo-MPH), d-threo-ethylphenidate (d-threo-EPH), l-threo-ethylphenidate (l-threo-EPH) and d,l-threo-ritalinic acid (d,l-threo-RA) in rat plasma over the linearity range of 1-500ng/mL. Chiral separation was performed on an Astec Chirobiotic V2 column (5μm, 250×2.1mm) with isocratic elution using methanol containing 0.003% ammonium acetate (w/v) and 0.003% trifluoroacetic acid (v/v) at a flow of 0.3mL/min. All analytes and IS were extracted from rat plasma by a one-step liquid-liquid extraction (LLE) method. The intra- and inter-run accuracies were within 85-115%, and the intra- and inter-run precision were <10% for all analytes. Extraction recoveries were 55-62% for d-threo-MPH, 54-60% for l-threo-MPH, 55-60% for d-threo-EPH, 53-57% for l-threo-EPH and 25-30% for d,l-threo-RA. The validated UFLC-MS/MS method successfully applied to the pharmacokinetic interaction study of oral d-threo-MPH and l-threo-MPH (alone or in combination) in female Sprague Dawley rats. The EPH was not detected in rat plasma following oral administrated MPH without EtOH. As far as it is known to the authors, this study is the first one step liquid-liquid extraction method to extract and UFLC-MS/MS method to quantify d-threo-MPH, l-threo-MPH, d-threo-EPH, l-threo-EPH and d,l-threo-RA simultaneously. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Software Tools and Approaches for Compound Identification of LC-MS/MS Data in Metabolomics

    Directory of Open Access Journals (Sweden)

    Ivana Blaženović

    2018-05-01

    Full Text Available The annotation of small molecules remains a major challenge in untargeted mass spectrometry-based metabolomics. We here critically discuss structured elucidation approaches and software that are designed to help during the annotation of unknown compounds. Only by elucidating unknown metabolites first is it possible to biologically interpret complex systems, to map compounds to pathways and to create reliable predictive metabolic models for translational and clinical research. These strategies include the construction and quality of tandem mass spectral databases such as the coalition of MassBank repositories and investigations of MS/MS matching confidence. We present in silico fragmentation tools such as MS-FINDER, CFM-ID, MetFrag, ChemDistiller and CSI:FingerID that can annotate compounds from existing structure databases and that have been used in the CASMI (critical assessment of small molecule identification contests. Furthermore, the use of retention time models from liquid chromatography and the utility of collision cross-section modelling from ion mobility experiments are covered. Workflows and published examples of successfully annotated unknown compounds are included.

  4. Identifying inaccuracy of MS Project using system analysis

    Science.gov (United States)

    Fachrurrazi; Husin, Saiful; Malahayati, Nurul; Irzaidi

    2018-05-01

    The problem encountered in project owner’s financial accounting report is the difference in total project costs of MS Project to the Indonesian Standard (Standard Indonesia Standard / Cost Estimating Standard Book of Indonesia). It is one of the MS Project problems concerning to its cost accuracy, so cost data cannot be used in an integrated way for all project components. This study focuses on finding the causes of inaccuracy of the MS Projects. The aim of this study, which is operationally, are: (i) identifying cost analysis procedures for both current methods (SNI) and MS Project; (ii) identifying cost bias in each element of the cost analysis procedure; and (iii) analysing the cost differences (cost bias) in each element to identify what the cause of inaccuracies in MS Project toward SNI is. The method in this study is comparing for both the system analysis of MS Project and SNI. The results are: (i) MS Project system in Work of Resources element has limitation for two decimal digits only, have led to its inaccuracy. Where the Work of Resources (referred to as effort) in MS Project represents multiplication between the Quantities of Activities and Requirements of resources in SNI; (ii) MS Project and SNI have differences in the costing methods (the cost estimation methods), in which the SNI uses the Quantity-Based Costing (QBC), meanwhile MS Project uses the Time-Based Costing (TBC). Based on this research, we recommend to the contractors who use SNI should make an adjustment for Work of Resources in MS Project (with correction index) so that it can be used in an integrated way to the project owner’s financial accounting system. Further research will conduct for improvement the MS Project as an integrated tool toward all part of the project participant.

  5. A novel study of screening and confirmation of modafinil, adrafinil and their metabolite modafinilic acid under EI-GC-MS and ESI-LC-MS-MS ionization.

    Science.gov (United States)

    Dubey, S; Ahi, S; Reddy, I M; Kaur, T; Beotra, A; Jain, S

    2009-12-01

    Adrafinil and modafinil have received wide publicity and have become controversial in the sporting world when several athletes were discovered allegedly using these drugs as doping agents. By acknowledging the facts, the World Anti-Doping Agency (WADA) banned these drugs in sports since 2004. The present study explores the possibility of differentiating adrafinil and modafinil and their major metabolites under electron impact ionization in gas chromatograph-mass spectrometer (GC-MSD) and electrospray ionization in liquid chromatograph-mass spectrometer (LC-MS/MS) by studying the fragmentation pattern of these drugs. Adrafinil, modafinil and their major metabolite, modafinilic acid were analyzed on EI-GC-MSD and ESI-LC-MS/MS using various individual parameters on both the instruments. The analytical technique and equipment used in the analysis were an Agilent 6890N GC with 5973 mass selective detector for the GC-MSD analysis and an Agilent 1100 HPLC with API-3200 Triple quadrupole mass spectrometer for the LC-MS/MS analysis. Validation of both methods was performed using six replicates at different concentrations. The results show that adrafinil, modafinil and their major metabolite modafinilic acid could be detected as a single artifact without differentiation under EI-GC-MSD analysis. However, all drugs could be detected and differentiated under ESI-LCMS/MS analysis without any artifaction. The GC-MSD analysis gives a single artifact for both the drugs without differentiation and thus can be used as a marker for screening purposes. Further, the Multiple Reaction Monitoring (MRM) method developed under LC-MS/MS is fit for the purpose for confirmation of suspicious samples in routine sports testing and in forensic and clinical analysis.

  6. UFLC-ESI-MS/MS analysis of multiple mycotoxins in medicinal and edible Areca catechu.

    Science.gov (United States)

    Liu, Hongmei; Luo, Jiaoyang; Kong, Weijun; Liu, Qiutao; Hu, Yichen; Yang, Meihua

    2016-05-01

    A robust, sensitive and reliable ultra fast liquid chromatography combined with electrospray ionization tandem mass spectrometry (UFLC-ESI-MS/MS) was optimized and validated for simultaneous identification and quantification of eleven mycotoxins in medicinal and edible Areca catechu, based on one-step extraction without any further clean-up. Separation and quantification were performed in both positive and negative modes under multiple reaction monitoring (MRM) in a single run with zearalanone (ZAN) as internal standard. The chromatographic conditions and MS/MS parameters were carefully optimized. Matrix-matched calibration was recommended to reduce matrix effects and improve accuracy, showing good linearity within wide concentration ranges. Limits of quantification (LOQ) were lower than 50 μg kg(-1), while limits of detection (LOD) were in the range of 0.1-20 μg kg(-1). The accuracy of the developed method was validated for recoveries, ranging from 85% to 115% with relative standard deviation (RSD) ≤14.87% at low level, from 75% to 119% with RSD ≤ 14.43% at medium level and from 61% to 120% with RSD ≤ 13.18% at high level, respectively. Finally, the developed multi-mycotoxin method was applied for screening of these mycotoxins in 24 commercial samples. Only aflatoxin B2 and zearalenone were found in 2 samples. This is the first report on the application of UFLC-ESI(+/-)-MS/MS for multi-class mycotoxins in A. catechu. The developed method with many advantages of simple pretreatment, rapid determination and high sensitivity is a proposed candidate for large-scale detection and quantification of multiple mycotoxins in other complex matrixes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Experiencing KM Tools and Methods in Publishing Technical Writing: Nuclear Malaysia Experience

    International Nuclear Information System (INIS)

    Normazlin Ismail; Mohd Hafizal Yusof; Habibah Adnan

    2015-01-01

    Knowledge Management (KM) is one of the approaches used by corporate nowadays in order to establish their business in meeting with their targets. For Nuclear Malaysia, one of the agencies under Ministry of Science, Technology and Innovation (MOSTI), nuclear knowledge management are strictly practiced as main players in managing the information and knowledge among their researchers. In addition, Nuclear Malaysia itself is unique where the nuclear knowledge is hardly developed through 40 years of its establishment. Through knowledge management, one project developed in order to capture researchers information and knowledge known as book writing. Researchers that experienced and experts in his or her fields are encouraged to write the technical book and published with the cooperation of Dewan Bahasa dan Pustaka (DBP). To date, there are several technical books are ready to publish and marketed among the universities and public. This paper will elaborate KM tools and methods applied during publishing technical writing in the Nuclear Malaysia. (author)

  8. Development, validation and clinical application of a method for the simultaneous quantification of lamivudine, emtricitabine and tenofovir in dried blood and dried breast milk spots using LC-MS/MS.

    Science.gov (United States)

    Waitt, Catriona; Diliiy Penchala, Sujan; Olagunju, Adeniyi; Amara, Alieu; Else, Laura; Lamorde, Mohammed; Khoo, Saye

    2017-08-15

    To present the validation and clinical application of a LC-MS/MS method for the quantification of lamivudine (3TC), emtricitabine (FTC) and tenofovir (TFV) in dried blood spots (DBS) and dried breast milk spots (DBMS). DBS and DBMS were prepared from 50 and 30μL of drug-spiked whole blood and human breast milk, respectively. Following extraction with acetonitrile and water, chromatographic separation utilised a Synergi polar column with a gradient mobile phase program consisting of 0.1% formic acid in water and 0.1% formic acid in acetonitrile. Detection and quantification was performed using a TSQ Quantum Ultra triple quadrupole mass spectrometer. The analytical method was used to evaluate NRTI drug levels in HIV-positive nursing mothers-infant pairs. The assay was validated over the concentration range of 16.6-5000ng/mL for 3TC, FTC and TFV in DBS and DBMS except for TFV in DBMS where linearity was established from 4.2-1250ng/mL. Intra and inter-day precision (%CV) ranged from 3.5-8.7 and accuracy was within 15% for all analytes in both matrices. The mean recovery in DBS was >61% and in DBMS >43% for all three analytes. Matrix effect was insignificant. Median AUC 0-8 values in maternal DBS and DBMS, respectively, were 4683 (4165-6057) and 6050 (5217-6417)ngh/mL for 3TC, 3312 (2259-4312) and 4853 (4124-6691)ngh/mL for FTC and 1559 (930-1915) and 56 (45-80)ngh/mL for TFV. 3TC and FTC were quantifiable (>16.6ng/mL) in DBS from 2/6 and 1/6 infants respectively whereas TFV was undetectable in all infants. DBS and DBMS sampling for bioanalysis of 3TC, FTC and TFV is straightforward, robust, accurate and precise, and ideal for use in low-resource settings. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  9. Development and Evaluation of a PCR and Mass Spectroscopy-based (PCR-MS) Method for Quantitative, Type-specific Detection of Human Papillomavirus

    Science.gov (United States)

    Patel, Divya A.; Shih, Yang-Jen; Newton, Duane W.; Michael, Claire W.; Oeth, Paul A.; Kane, Michael D.; Opipari, Anthony W.; Ruffin, Mack T.; Kalikin, Linda M.; Kurnit, David M.

    2010-01-01

    Knowledge of the central role of high-risk human papillomavirus (HPV) in cervical carcinogenesis, coupled with an emerging need to monitor the efficacy of newly introduced HPV vaccines, warrant development and evaluation of type-specific, quantitative HPV detection methods. In the present study, a prototype PCR and mass spectroscopy (PCR-MS)-based method to detect and quantitate 13 high-risk HPV types is compared to the Hybrid Capture 2 High Risk HPV DNA test (HC2; Digene Corp., Gaithersburg, MD) in 199 cervical scraping samples and to DNA sequencing in 77 cervical tumor samples. High-risk HPV types were detected in 76/77 (98.7%) cervical tumor samples by PCR-MS. Degenerate and type-specific sequencing confirmed the types detected by PCR-MS. In 199 cervical scraping samples, all 13 HPV types were detected by PCR-MS. Eighteen (14.5%) of 124 cervical scraping samples that were positive for high-risk HPV by HC2 were negative by PCR-MS. In all these cases, degenerate DNA sequencing failed to detect any of the 13 high-risk HPV types. Nearly half (46.7%) of the 75 cervical scraping samples that were negative for high-risk HPV by the HC2 assay were positive by PCR-MS. Type-specific sequencing in a subset of these samples confirmed the HPV type detected by PCR-MS. Quantitative PCR-MS results demonstrated that 11/75 (14.7%) samples contained as much HPV copies/cell as HC2-positive samples. These findings suggest that this prototype PCR-MS assay performs at least as well as HC2 for HPV detection, while offering the additional, unique advantages of type-specific identification and quantitation. Further validation work is underway to define clinically meaningful HPV detection thresholds and to evaluate the potential clinical application of future generations of the PCR-MS assay. PMID:19410602

  10. Development and evaluation of a PCR and mass spectroscopy (PCR-MS)-based method for quantitative, type-specific detection of human papillomavirus.

    Science.gov (United States)

    Patel, Divya A; Shih, Yang-Jen; Newton, Duane W; Michael, Claire W; Oeth, Paul A; Kane, Michael D; Opipari, Anthony W; Ruffin, Mack T; Kalikin, Linda M; Kurnit, David M

    2009-09-01

    Knowledge of the central role of high-risk human papillomavirus (HPV) in cervical carcinogenesis, coupled with an emerging need to monitor the efficacy of newly introduced HPV vaccines, warrant development and evaluation of type-specific, quantitative HPV detection methods. In the present study, a prototype PCR and mass spectroscopy (PCR-MS)-based method to detect and quantitate 13 high-risk HPV types is compared to the Hybrid Capture 2 High-Risk HPV DNA test (HC2; Digene Corp., Gaithersburg, MD) in 199 cervical scraping samples and to DNA sequencing in 77 cervical tumor samples. High-risk HPV types were detected in 76/77 (98.7%) cervical tumor samples by PCR-MS. Degenerate and type-specific sequencing confirmed the types detected by PCR-MS. In 199 cervical scraping samples, all 13 HPV types were detected by PCR-MS. Eighteen (14.5%) of 124 cervical scraping samples that were positive for high-risk HPV by HC2 were negative by PCR-MS. In all these cases, degenerate DNA sequencing failed to detect any of the 13 high-risk HPV types. Nearly half (46.7%) of the 75 cervical scraping samples that were negative for high-risk HPV by the HC2 assay were positive by PCR-MS. Type-specific sequencing in a subset of these samples confirmed the HPV type detected by PCR-MS. Quantitative PCR-MS results demonstrated that 11/75 (14.7%) samples contained as much HPV copies/cell as HC2-positive samples. These findings suggest that this prototype PCR-MS assay performs at least as well as HC2 for HPV detection, while offering the additional, unique advantages of type-specific identification and quantitation. Further validation work is underway to define clinically meaningful HPV detection thresholds and to evaluate the potential clinical application of future generations of the PCR-MS assay.

  11. Model independent method to deconvolve hard X-ray spectra

    Energy Technology Data Exchange (ETDEWEB)

    Polcaro, V.F.; Bazzano, A.; Ubertini, P.; La Padula, C. (Consiglio Nazionale delle Ricerche, Frascati (Italy). Lab. di Astrofisica Spaziale); Manchanda, R.K. (Tata Inst. of Fundamental Research, Bombay (India))

    1984-07-01

    A general purpose method to deconvolve the energy spectra detected by means of the use of a hard X-ray telescope is described. The procedure does not assume any form of input spectrum and the observed energy loss spectrum is directly deconvolved into the incident photon spectrum, the form of which can be determined independently of physical interpretation of the data. Deconvolution of the hard X-ray spectrum of Her X-1, detected during the HXR 81M experiment, by the method independent method is presented.

  12. Structural and magnetic studies of the Co{sub 1+x}Ti{sub x}Fe{sub 2(1−x)}O{sub 4} ferrites

    Energy Technology Data Exchange (ETDEWEB)

    Amer, M.A., E-mail: moazamer@hotmail.com

    2017-03-15

    The cubic spinel Co{sub 1+x}Ti{sub x}Fe{sub 2(1−x)}O{sub 4} ferrites, 0.0≤x≤0.5, were prepared by the standard ceramic technique. The samples were examined using the techniques; XRD, FT-IR, SEM and VSM. The average lattice parameter showed dependence on x, whereas the crystallite and grain size and strain did not. The infrared spectra showed six absorption bands in the range of 200–1000 cm{sup −1}. They were assigned to the corresponding metallic ion–oxygen bonds among the A- and B-sites. The absorption bands ν{sub 1} and ν{sub 2} and their intensities and force constants F{sub 1} and F{sub 2} were increased against x. Using the transmitted and absorbed energy, the IR velocity and refractive index and jump rate of vacancies were determined and discussed as functions of x. The trend of sauration magnetization Ms was decreased with x, whereas that of coercivity and anisotropy constant was increased. The determined Debye temperature and stiffness constant of the samples were discussed as functions of x. The absorption bands ν{sub 1} and ν{sub 2} proved dependence on the distance between magnetic ions (hopping length) L{sub A-A} and L{sub B-B} at the A- and B-sites, respectively, whereas F{sub 1} and F{sub 2} proved dependence on Ms. - Highlights: • Trend of Ms showed decrease with x, whereas that of Hc and K showed increase. • IR velocity and refractive index and jump rate of vacancies revealed dependence on x. • Debye temperature and stiffness constant showed increase with the additional factor x. • IR bands ν{sub 1} and ν{sub 2} were decreased with the distance between magnetic ions L{sub A} and L{sub B}. • Force constants F{sub 1} and F{sub 2} were affected by the saturation magnetization Ms.

  13. Dual quantification of dapivirine and maraviroc in cervicovaginal secretions from ophthalmic tear strips and polyester-based swabs via liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis.

    Science.gov (United States)

    Parsons, Teresa L; Emory, Joshua F; Seserko, Lauren A; Aung, Wutyi S; Marzinke, Mark A

    2014-09-01

    Topical microbicidal agents are being actively pursued as a modality to prevent HIV viral transmission during sexual intercourse. Quantification of antiretroviral agents in specimen sources where antiviral activity is elicited is critical, and drug measurements in cervicovaginal fluid can provide key information on local drug concentrations. Two antiretroviral drugs, dapivirine and maraviroc, have gained interest as vaginal microbicidal agents, and rugged methods are required for their quantification in cervicovaginal secretions. Cervicovaginal fluid spiked with dapivirine and maraviroc were applied to ophthalmic tear strips or polyester-based swabs to mimic collection procedures used in clinical studies. Following sample extraction and the addition of isotopically labeled internal standards, samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis using a Waters BEH C8, 50mm×2.1mm, 1.7μm particle size column, on an API 4000 mass analyzer operated in selective reaction monitoring mode. The method was validated according to FDA Bioanalytical Method Validation guidelines. Due to the disparate saturation capacity of the tested collection devices, the analytical measuring ranges for dapivirine and maravirocin cervicovaginal fluid on the ophthalmic tear strip were 0.05-25ng/tear strip, and 0.025-25ng/tear strip, respectively. As for the polyester-based swab, the analytical measuring ranges were 0.25-125ng/swab for dapivirine and 0.125-125ng/swab for maraviroc. Dilutional studies were performed for both analytes to extended ranges of 25,000ng/tear strip and 11,250ng/swab. Standard curves were generated via weighted (1/x(2)) linear or quadratic regression of calibrators. Precision, accuracy, stability and matrix effects studies were all performed and deemed acceptable according to the recommendations of the FDA Bioanalytical Method Validation guidelines. A rugged LC-MS/MS method for the dual quantification of dapivirine and

  14. Accurate determination of ultra-trace levels of Ti in blood serum using ICP-MS/MS

    International Nuclear Information System (INIS)

    Balcaen, Lieve; Bolea-Fernandez, Eduardo; Resano, Martín; Vanhaecke, Frank

    2014-01-01

    Graphical abstract: -- Highlights: •Novel method for determination of Ti at ultra-trace levels in clinical samples (serum). •Novel method based on Ti(NH 3 ) 6 + reaction product ion formation and double mass selection using recently introduced ICP-QQQ instrumentation. •Lowest limits of detection ever obtained using quadrupole-based instrumentation for Ti. •Accurate determination of basal levels of Ti in blood serum. -- Abstract: Ti is frequently used in implants and prostheses and it has been shown before that the presence of these in the human body can lead to elevated Ti concentrations in body fluids such as serum and urine. As identification of the exact mechanisms responsible for this increase in Ti concentrations, and the risks associated with it, are not fully understood, it is important to have sound analytical methods that enable straightforward quantification of Ti levels in body fluids (for both implanted and non-implanted individuals). Until now, only double-focusing sector field ICP-mass spectrometry (SF-ICP-MS) offered limits of detection that are good enough to deal with the very low basal levels of Ti in human serum. This work reports on the development of a novel method for the accurate and precise determination of trace levels of Ti in human serum samples, based on the use of ICP-MS/MS. O 2 and NH 3 /He have been compared as reaction gases. While the use of O 2 did not enable to overcome all spectral interferences, it has been shown that conversion of Ti + ions into Ti(NH 3 ) 6 + cluster ions by using NH 3 /He as a reaction gas in an ICP-QQQ-MS system, operated in MS/MS mode, provided interference-free conditions and sufficiently low limits of detection, down to 3 ng L −1 (instrumental detection limit obtained for the most abundant Ti isotope). The accuracy of the method proposed was evaluated by analysis of a Seronorm Trace Elements Serum L-1 reference material and by comparing the results obtained with those achieved by means of SF-ICP-MS

  15. IsoMS: automated processing of LC-MS data generated by a chemical isotope labeling metabolomics platform.

    Science.gov (United States)

    Zhou, Ruokun; Tseng, Chiao-Li; Huan, Tao; Li, Liang

    2014-05-20

    A chemical isotope labeling or isotope coded derivatization (ICD) metabolomics platform uses a chemical derivatization method to introduce a mass tag to all of the metabolites having a common functional group (e.g., amine), followed by LC-MS analysis of the labeled metabolites. To apply this platform to metabolomics studies involving quantitative analysis of different groups of samples, automated data processing is required. Herein, we report a data processing method based on the use of a mass spectral feature unique to the chemical labeling approach, i.e., any differential-isotope-labeled metabolites are detected as peak pairs with a fixed mass difference in a mass spectrum. A software tool, IsoMS, has been developed to process the raw data generated from one or multiple LC-MS runs by peak picking, peak pairing, peak-pair filtering, and peak-pair intensity ratio calculation. The same peak pairs detected from multiple samples are then aligned to produce a CSV file that contains the metabolite information and peak ratios relative to a control (e.g., a pooled sample). This file can be readily exported for further data and statistical analysis, which is illustrated in an example of comparing the metabolomes of human urine samples collected before and after drinking coffee. To demonstrate that this method is reliable for data processing, five (13)C2-/(12)C2-dansyl labeled metabolite standards were analyzed by LC-MS. IsoMS was able to detect these metabolites correctly. In addition, in the analysis of a (13)C2-/(12)C2-dansyl labeled human urine, IsoMS detected 2044 peak pairs, and manual inspection of these peak pairs found 90 false peak pairs, representing a false positive rate of 4.4%. IsoMS for Windows running R is freely available for noncommercial use from www.mycompoundid.org/IsoMS.

  16. Revealing of endogenous Marinobufagin by an ultra-specific and sensitive UHPLC-MS/MS assay in pregnant women.

    Science.gov (United States)

    Lenaerts, Charline; Bond, Liz; Tuytten, Robin; Blankert, Bertrand

    2018-09-01

    Marinobufagenin (MBG) is a bufadienolide cardiac inotrope implicated in volume expansion-mediated hypertensive states including essential hypertension and preeclampsia (PE). Endogenous MBG is an inhibitor of the α1-isoform of Na + ,K + -ATPase with vasoconstrictive and cardiotonic properties, causing hypertension and natriuresis. Elevated endogenous MBG-like material levels have been described by immunoassays in salt-sensitive pregnant and preeclamptic rats as well as in preeclamptic human patients. The rise of endogenous MBG-like material appears prior the development of the main symptoms of PE, leading us to consider MBG as one of the potential biomarkers for PE. The weak specificity and the high variability of the published immunoassays gives no certification about endogenous MBG existence. This led us to set-up a highly specific and sensitive analytical method to detect MBG in plasma at low levels relying on liquid chromatography combined to mass spectrometry (UHPLC-MS/MS) with recording of 7 highly specific MRM transitions for MBG. Pure MBG standard used in the method development was obtained by purification from the Bufo marinus toad venom. d 3 -25-hydroxyvitamin D3 was used as internal standard. An increasing organic gradient with mobile phase A and B composed of 97:3 (v/v) H 2 O: MeOH and 50:45:5 (v/v/v) MeOH:IPA:H 2 O at pH 4.5 respectively was used on a Pursuit 3 PFP column (100 mm × 3 mm; 3 µm) to allow elution and separation of the plasmatic compounds. Chromatographic analyses of plasma samples were preceded by a precipitation of proteins pretreatment. The developed UHPLC-MS/MS assay has been applied to early-pregnant women plasma samples allowing us to investigate MBG plasma levels. Thanks to the high specificity of the assay we were able to authenticate and certify the presence of endogenous MBG in early-pregnant women plasma with the use of the 7 selected specific mass transitions. These pioneering preliminary results are giving a

  17. Simultaneous quantification of the organophosphorus pesticides dimethoate and omethoate in porcine plasma and urine by LC-ESI-MS/MS and flow-injection-ESI-MS/MS.

    Science.gov (United States)

    John, Harald; Eddleston, Michael; Clutton, R Eddie; Worek, Franz; Thiermann, Horst

    2010-05-15

    Dimethoate is an organophosphorus toxicant used in agri- and horticulture as a systemic broad-spectrum insecticide. It also exhibits toxic activity towards mammalian organism provoked by catalytic desulfuration in the liver producing its oxon-derivative omethoate thus inhibiting acetylcholinesterase, initiating cholinergic crisis and ultimately leading to death by respiratory paralysis and cardiovascular collapse. Pharmaco- and toxicokinetic studies in animal models help to broaden basic understanding of medical intervention by antidotes and supportive care. Therefore, we developed and validated a LC-ESI-MS/MS method suitable for the simultaneous, selective, precise (RSD(intra-day) 1-8%; RSD(inter-day) 5-14%), accurate (intra-day: 95-107%; inter-day: 90-115%), and robust quantification of both pesticides from porcine urine and plasma after deproteinization by precipitation and extensive dilution (1:11,250 for plasma and 1:40,000 for urine). Accordingly, lower limits of quantification (0.24-0.49 microg/ml plasma and 0.78-1.56 microg/ml urine) and lower limits of detection (0.12-0.24 microg/ml plasma and 0.39-0.78 microg/ml urine) were equivalent to quite low absolute on-column amounts (1.1-2.1 pg for plasma and 2.0-3.9 pg for urine). The calibration range (0.24-250 microg/ml plasma and 0.78-200 microg/ml urine) was subdivided into two linear ranges (r(2)>or=0.998) each covering nearly two orders of magnitude. The lack of any interfering peak in 6 individual blank specimens from plasma and urine demonstrated the high selectivity of the method. Furthermore, extensive sample dilution causing lowest concentration of potentially interfering matrix ingredients prompted us to develop and validate an additional flow-injection method (FI-ESI-MS/MS). Validation characteristics were as good as for the chromatographic method but sample throughput was enhanced by a factor of 6. Effects on ionization provoked by plasma and urine matrix from 6 individuals as well as in the

  18. Single-cell analysis by ICP-MS/MS as a fast tool for cellular bioavailability studies of arsenite.

    Science.gov (United States)

    Meyer, S; López-Serrano, A; Mitze, H; Jakubowski, N; Schwerdtle, T

    2018-01-24

    Single-cell inductively coupled plasma mass spectrometry (SC-ICP-MS) has become a powerful and fast tool to evaluate the elemental composition at a single-cell level. In this study, the cellular bioavailability of arsenite (incubation of 25 and 50 μM for 0-48 h) has been successfully assessed by SC-ICP-MS/MS for the first time directly after re-suspending the cells in water. This procedure avoids the normally arising cell membrane permeabilization caused by cell fixation methods (e.g. methanol fixation). The reliability and feasibility of this SC-ICP-MS/MS approach with a limit of detection of 0.35 fg per cell was validated by conventional bulk ICP-MS/MS analysis after cell digestion and parallel measurement of sulfur and phosphorus.

  19. Identification of hormone esters in injection site in muscle tissues by LC/MS/MS.

    Science.gov (United States)

    Costain, R M; Fesser, A C E; McKenzie, D; Mizuno, M; MacNeil, J D

    2008-12-01

    The detection of hormone abuse for growth promotion in food animal production is a global concern. Initial testing for hormones in Canada was directed at the compounds approved for use in beef cattle, melengestrol acetate, trenbolone acetate and zeranol, and the banned compound diethylstilbestrol (DES). No hormonal growth promoters are approved for use in veal production in Canada. However, instances of use of trenbolone and clenbuterol were detected in Canada in the 1990s. During the development of a new analytical method for testosterone and progesterone, there were reports of suspicious injection sites being found in veal calves. Upon implementation of the method, analysis of investigative samples revealed significant residues of testosterone in some injection sites. To prove that the source of these residues was exogenous, a fully validated method for hormone esters was developed to confirm the presence of exogenous hormones in these injection sites. The QUECHERS model was employed in methods development and resulted in a simple, effective extraction technique that consisted of sample pre-homogenization, liquid/liquid partitioning, extract dilution, filtration and use of LC/MS/MS to provide detection selectivity. The result was an adaptable MS/MS confirmation technique that meets the needs of Canadian regulatory authorities to confirm the misuse of injectable testosterone, and potentially other hormones, in food animal production.

  20. Validation of an UHPLC-MS/MS Method for Screening of Antimicrobial Residues in Eggs and Their Application to Analyses of Eggs from Laying Hens Subjected to Pharmacological Treatment

    Directory of Open Access Journals (Sweden)

    Letícia Gomes Magnago Caldeira

    2017-01-01

    Full Text Available A multiresidue method by UHPLC/MS-MS was optimized and validated for the screening and semiquantitative detection of antimicrobials residues from tetracyclines, aminoglycosides, quinolones, lincosamides, β-lactams, sulfonamides, and macrolides families in eggs. A qualitative approach was used to ensure adequate sensitivity to detect residues at the level of interest, defined as maximum residue limit (MRL, or less. The applicability of the methods was assessed by analyzing egg samples from hens that had been subjected to pharmacological treatment with neomycin, enrofloxacin, lincomycin, oxytetracycline, and doxycycline during five days and after discontinuation of medication (10 days. The method was adequate for screening all studied analytes in eggs, since the performance parameters ensured a false-compliant rate below or equal to 5%, except for flumequine. In the analyses of eggs from laying hens subjected to pharmacological treatment, all antimicrobial residues were detected throughout the experimental period, even after discontinuation of medication, except for neomycin, demonstrating the applicability of the method for analyses of antimicrobial residues in eggs.

  1. Measuring the black hole mass in ultraluminous X-ray sources with the X-ray scaling method

    Science.gov (United States)

    Jang, I.; Gliozzi, M.; Satyapal, S.; Titarchuk, L.

    2018-01-01

    In our recent work, we demonstrated that a novel X-ray scaling method, originally introduced for Galactic black holes (BH), could be reliably extended to estimate the mass of supermassive black holes accreting at moderate to high level. Here, we apply this X-ray scaling method to ultraluminous X-ray sources (ULXs) to constrain their MBH. Using 49 ULXs with multiple XMM-Newton observations, we infer that ULXs host both stellar mass BHs and intermediate mass BHs. The majority of the sources of our sample seem to be consistent with the hypothesis of highly accreting massive stellar BHs with MBH ∼ 100 M⊙. Our results are in general agreement with the MBH values obtained with alternative methods, including model-independent variability methods. This suggests that the X-ray scaling method is an actual scale-independent method that can be applied to all BH systems accreting at moderate-high rate.

  2. Misleading measures in Vitamin D analysis: A novel LC-MS/MS assay to account for epimers and isobars

    Directory of Open Access Journals (Sweden)

    Petroczi Andrea

    2011-05-01

    Full Text Available Abstract Background Recently, the accuracies of many commercially available immunoassays for Vitamin D have been questioned. Liquid chromatography tandem mass spectrometry (LC- MS/MS has been shown to facilitate accurate separation and quantification of the major circulating metabolite 25-hydroxyvitamin-D3 (25OHD3 and 25-hydroxyvitamin-D2 (25OHD2 collectively termed as 25OHD. However, among other interferents, this method may be compromised by overlapping peaks and identical masses of epimers and isobars, resulting in inaccuracies in circulating 25OHD measurements. The aim of this study was to develop a novel LC-MS/MS method that can accurately identify and quantitate 25OHD3 and 25OHD2 through chromatographic separation of 25OHD from its epimers and isobars. Methods A positive ion electrospray ionisation (ESI LC-MS/MS method was used in the Multiple Reaction Monitoring (MRM mode for quantification. It involved i liquid-liquid extraction, ii tandem columns (a high resolution ZORBAX C18 coupled to an ULTRON chiral, with guard column and inlet filter, iii Stanozolol-D3 as internal standard, and iv identification via ESI and monitoring of three fragmentation transitions. To demonstrate the practical usefulness of our method, blood samples were collected from 5 healthy male Caucasian volunteers; age range 22 to 37 years and 25OHD2, 25OHD3 along with co-eluting epimers and analogues were quantified. Results The new method allowed chromatographic separation and quantification of 25OHD2, 25OHD3, along with 25OHD3 epimer 3-epi-25OHD3 and isobars 1-α-hydroxyvitamin-D3 (1αOHD3, and 7-α-hydroxy-4-cholesten-3-one (7αC4. The new assay was capable of detecting 0.25 ng/mL of all analytes in serum. Conclusions To our knowledge, this is the first specific, reliable, reproducible and robust LC-MS/MS method developed for the accurate detection of 25OHD (Vitamin D. The method is capable of detecting low levels of 25OHD3 and 25OHD2 together with chromatographic

  3. Aptamer based peptide enrichment for quantitative analysis of gonadotropin-releasing hormone by LC-MS/MS.

    Science.gov (United States)

    Richards, S L; Cawley, A T; Cavicchioli, R; Suann, C J; Pickford, R; Raftery, M J

    2016-04-01

    Over recent years threats to racing have expanded to include naturally occurring biological molecules, such as peptides and proteins, and their synthetic analogues. Traditionally, antibodies have been used to enable detection of these compounds as they allow purification and concentration of the analyte of interest. The rapid expansion of peptide-based therapeutics necessitates a similarly rapid development of suitable antibodies or other means of enrichment. Potential alternative enrichment strategies include the use of aptamers, which offer the significant advantage of chemical synthesis once the nucleic acid sequence is known. A method was developed for the enrichment, detection and quantitation of gonadotropin-releasing hormone (GnRH) in equine urine using aptamer-based enrichment and LC-MS/MS. The method achieved comparable limits of detection (1 pg/mL) and quantification (2.5 pg/mL) to previously published antibody-based enrichment methods. The intra- and inter-assay precision achieved was less than 10% at both 5 and 20 pg/mL, and displayed a working dynamic range of 2.5-100 pg/mL. Significant matrix enhancement (170 ± 8%) and low analytical recovery (29 ± 15%) was observed, although the use of an isotopically heavy labelled GnRH peptide, GnRH (Pro(13)C5,(15)N), as the internal standard provides compensation for these parameters. Within the current limits of detection GnRH was detectable up to 1h post administration in urine and identification of a urinary catabolite extended this detection window to 4h. Based on the results of this preliminary investigation we propose the use of aptamers as a viable alternative to antibodies in the enrichment of peptide targets from equine urine. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. IDENTIFICATIONS AND PHOTOMETRIC REDSHIFTS OF THE 2 Ms CHANDRA DEEP FIELD-SOUTH SOURCES

    International Nuclear Information System (INIS)

    Luo, B.; Brandt, W. N.; Xue, Y. Q.; Rafferty, D. A.; Schneider, D. P.; Brusa, M.; Alexander, D. M.; Lehmer, B. D.; Bauer, F. E.; Comastri, A.; Koekemoer, A.; Mainieri, V.; Silverman, J. D.; Vignali, C.

    2010-01-01

    We present reliable multiwavelength identifications and high-quality photometric redshifts for the 462 X-ray sources in the ∼2 Ms Chandra Deep Field-South (CDF-S) survey. Source identifications are carried out using deep optical-to-radio multiwavelength catalogs, and are then combined to create lists of primary and secondary counterparts for the X-ray sources. We identified reliable counterparts for 442 (95.7%) of the X-ray sources, with an expected false-match probability of ∼ 6.2%; we also selected four additional likely counterparts. The majority of the other 16 X-ray sources appear to be off-nuclear sources, sources associated with galaxy groups and clusters, high-redshift active galactic nuclei (AGNs), or spurious X-ray sources. A likelihood-ratio method is used for source matching, which effectively reduces the false-match probability at faint magnitudes compared to a simple error-circle matching method. We construct a master photometric catalog for the identified X-ray sources including up to 42 bands of UV-to-infrared data, and then calculate their photometric redshifts (photo-z's). High accuracy in the derived photo-z's is accomplished owing to (1) the up-to-date photometric data covering the full spectral energy distributions (SEDs) of the X-ray sources, (2) more accurate photometric data as a result of source deblending for ∼10% of the sources in the infrared bands and a few percent in the optical and near-infrared bands, (3) a set of 265 galaxy, AGN, and galaxy/AGN hybrid templates carefully constructed to best represent all possible SEDs, (4) the Zurich Extragalactic Bayesian Redshift Analyzer used to derive the photo-z's, which corrects the SED templates to best represent the SEDs of real sources at different redshifts and thus improves the photo-z quality. The reliability of the photo-z's is evaluated using the subsample of 220 sources with secure spectroscopic redshifts. We achieve an accuracy of |Δz|/(1 + z) ∼ 1% and an outlier [with |

  5. X-ray spectrum local method

    International Nuclear Information System (INIS)

    Avdonin, S.A.

    1985-01-01

    General characteristic and bases of X-ray spectrum local method used for qualitative and quantitative analyses of the mineral chemical composition with volumetric locality of several cubic micrometers. The method is based on the excitation in a sample of characteristic and bremsstrahlung spectra by means of a narrow electron beam at 5-50 keV accelerating voltage. Application of the method when studying uranium minerals and ores is considered. The method allows to determine the uranium presence forms in the ores, morphological features of the minerals, mineral microstructure, UO 2 and UO 3 ratios for unhydrous uraninites and pitchblendes and also to determine mineralization age

  6. An LC-MS/MS method for simultaneous determination of three Polygala saponin hydrolysates in rat plasma and its application to a pharmacokinetic study.

    Science.gov (United States)

    Wang, Qian; Xiao, Bing-Xin; Pan, Rui-Le; Liu, Xin-Min; Liao, Yong-Hong; Feng, Li; Cao, Fang-Rui; Chang, Qi

    2015-07-01

    Radix Polygala has a long history of use as a sedative in traditional Chinese medicine and its major ingredients are saponins, which are recognized effective in memory improvement but highly toxic to gastricintestinal mucosa. Polygala saponin hydrolysates (PSH), an alkaline hydrolysis product and also the intestinal metabolites of the saponins, exhibited stronger effects in improving memory of mice and had less toxicity than its original saponins. The present study aims to develop a sensitive LC-MS/MS method for simultaneously determining PSH three major active components, 3,4,5-trimethoxycinnamylic acid (TMCA), p-methoxycinnamylic acid (PMCA) and tenuifolin (TF), in rat plasma and apply the method to a pharmacokinetic study. The acidic plasma (100μl) was treated by liquid-liquid extraction with ethyl acetate and reconstituted sample was analyzed on a C18 column eluted with acetonitrile-water (50:50) containing 0.2% formic acid at 0.4ml/min. The mass detection in negative electrospray ionization was used. The ion pairs for multiple reaction monitoring were set at m/z 237.0/103.0, 177.0/116.6 and 679.5/425.3 for TMCA, PMCA and TF, respectively. Their pharmacokinetic profiles were studied in rats after intravenous and oral dose of PSH at 20 and 100mg/kg, respectively. The calibration curves had good linearity (r(2)>0.99) for TMCA, PMCA and TF within the tested concentration ranges. The limits of detection and quantification were 1, 10, 0.5ng/ml and 10.0, 20.0, 1.0ng/ml, respectively. The intra-day and inter-day precisions were less than 18.9% and accuracies between 93.2% and 113.3%, and the extraction recovery ranged from 91.2% to 112.1% for all analytes. The pharmacokinetic study showed that TMCA, PMCA and TF could be rapidly absorbed into the circulation and reached their peak concentrations at about 9.1, 9.0 and 24.0min, respectively. TF had a lower oral bioavailability (2.0%) than TMCA (90.1%) and PMCA (96.5%), but it remained in the body much longer (t1/2,

  7. Determination of rhenium traces in river water by Q-ICP-MS and HR-ICP-MS

    International Nuclear Information System (INIS)

    Uchida, S.; Tagami, K.; Saito, M.

    2003-01-01

    A simple separation method was applied to determine rhenium in river water using Q-ICP-MS and HR-ICP-MS. Re was concentrated from 420-925 ml river water using a TEVA resin minicolumn. Such extraction using a resin could separate Re from most sample matrices and trace elements. Almost 100% recovery was found throughout the method as determined with radioactive multitracers. The HR-ICP-MS was also used for the direct determination because of its low detection limit for Re (0.007 pg/ml). The Re concentration in the river water samples ranged from 0.9 to 6.5 pg/ml and the three analysis results showed good agreement with each other. (author)

  8. Simultaneous quantitative analysis of nine vitamin D compounds in human blood using LC-MS/MS.

    Science.gov (United States)

    Abu Kassim, Nur Sofiah; Gomes, Fabio P; Shaw, Paul Nicholas; Hewavitharana, Amitha K

    2016-01-01

    It has been suggested that each member of the family of vitamin D compounds may have different function(s). Therefore, selective quantification of each compound is important in clinical research. Development and validation attempts of a simultaneous determination method of 12 vitamin D compounds in human blood using precolumn derivatization followed by LC-MS/MS is described. Internal standard calibration with 12 stable isotope labeled analogs was used to correct for matrix effects in MS detector. Nine vitamin D compounds were quantifiable in blood samples with detection limits within femtomole levels. Serum (compared with plasma) was found to be a more suitable sample type, and protein precipitation (compared with saponification) a more effective extraction method for vitamin D assay.

  9. What comes first? Publishing business or publishing studies?

    Directory of Open Access Journals (Sweden)

    Josipa Selthofer

    2015-07-01

    Full Text Available The aim of this paper is to analyze and compare publishing studies, their programmes at the undergraduate and graduate levels and scholars involved in the teaching of publishing courses at the top universities around the world and in Croatia. Since traditional publishing business is rapidly changing, new skills and new jobs are involved in it. The main research question is: Can modern publishing studies produce a modern publisher? Or, is it the other way around? The hypothesis of the paper is that scholars involved in the teaching of publishing courses at the top universities around the world have a background in publishing business. So, can they prepare their students for the future and can their students gain competencies they need to compete in a confusing world of digital authors and electronic books? The research methods used were content analysis and comparison. Research sample included 36 university publishing programmes at the undergraduate and graduate level worldwide (24 MA, 12 BA. The research sample was limited mainly to the English-speaking countries. In most non-English-speaking countries, it was difficult to analyse the programme curriculum in the native language because the programme and course description did not exit. In the data gathering phase, a customized web application was used for content analysis. The application has three main sections: a list of websites to evaluate, a visual representation of the uploaded website and a list of characteristics grouped by categories for quantifying data. About twenty years ago, publishing was not considered a separate scientific branch in Croatia. Publishing studies are therefore a new phenomenon to both scholars and publishers in Croatia. To create a new, ideal publishing course, can we simply copy global trends or is it better to create something of our own?

  10. Multidimensional protein fractionation of blood proteins coupled to data-independent nanoLC-MS/MS analysis.

    Science.gov (United States)

    Levin, Yishai; Jaros, Julian A J; Schwarz, Emanuel; Bahn, Sabine

    2010-01-03

    In order to exploit human blood as a source of protein disease biomarkers, robust analytical methods are needed to overcome the inherent molecular complexity of this bio-fluid. We present the coupling of label-free SAX chromatography and IMAC to a data-independent nanoLC-MS/MS (nanoLC-MS(E)) platform for analysis of blood plasma and serum proteins. The methods were evaluated using protein standards added at different concentrations to two groups of samples. The results demonstrate that both techniques enable accurate protein quantitation using low sample volumes and a minimal number of fractions. Combining both methods, 883 unique proteins were identified, of which 423 proteins showed high reproducibility. The two approaches resulted in identification of unique molecular signatures with an overlap of approximately 30%, thus providing complimentary information on sub-proteomes. These methods are potentially useful for systems biology, biomarker discovery, and investigation of phosphoproteins in blood. (c) 2009 Elsevier B.V. All rights reserved.

  11. Vigabatrin in dried plasma spots: validation of a novel LC-MS/MS method and application to clinical practice.

    Science.gov (United States)

    Kostić, Nađa; Dotsikas, Yannis; Jović, Nebojša; Stevanović, Galina; Malenović, Anđelija; Medenica, Mirjana

    2014-07-01

    This paper presents a LC-MS/MS method for the determination of antiepileptic drug vigabatrin in dried plasma spots (DPS). Due to its zwitterionic chemical structure, a pre-column derivatization procedure was performed, aiming to yield enhanced ionization efficiency and improved chromatographic behaviour. Propyl chloroformate, in the presence of propanol, was selected as the best derivatization reagent, providing a strong signal along with reasonable run time. A relatively novel sample collection technique, DPS, was utilized, offering easy sample handling and analysis, using a sample in micro amount (∼5μL). Derivatized vigabatrin and its internal standard, 4-aminocyclohexanecarboxylic acid, were extracted by liquid-liquid extraction (LLE) and determined in positive ion mode by applying two SRM transitions per analyte. A Zorbax Eclipse XDB-C8 column (150×4.6mm, 5μm particle size) maintained at 30°C, was utilized with running mobile phase composed of acetonitrile: 0.15% formic acid (85:15, v/v). Flow rate was 550μL/min and total run time 4.5min. The assay exhibited excellent linearity over the concentration range of 0.500-50.0μg/mL, which is suitable for the determination of vigabatrin level after per os administration in children and youths with epilepsy, who were on vigabatrin therapy, with or without co-medication. Specificity, accuracy, precision, recovery, matrix-effect and stability were also estimated and assessed within acceptance criteria. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Simultaneous analysis of regorafenib and sorafenib and three of their metabolites in human plasma using LC-MS/MS.

    Science.gov (United States)

    Allard, Marie; Khoudour, Nihel; Rousseau, Benoît; Joly, Charlotte; Costentin, Charlotte; Blanchet, Benoît; Tournigand, Christophe; Hulin, Anne

    2017-08-05

    A new liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, performed by electrospray ionization in positive mode using a triple quadrupole mass spectrometry, has been developed and validated for the simultaneous determination of regorafenib (REGO), its two metabolites regorafenib-M2 and regorafenib-M5, sorafenib (SORA), and its N-oxide metabolite in human plasma. Separation is achieved on an Hypersil Gold ® column using a gradient elution of 10mM ammonium formate containing 0.1% formic acid (A) and acetonitrile containing 0.1% formic acid (B) at a flow rate of 0.3mL/min. After addition of two internal standards and a protein precipitation, the supernatant is diluted two-fold in a 0.1% (v/v) formic acid solution. Two selected reaction monitoring transitions are used, for each analyte, one for quantitation and the second one for confirmation. The standard curves are ranged from 50 to 5 000ng/mL for REGO and its metabolites and 80 to 5 000ng/mL for SORA and its metabolite and were fitted to a 1/x weighted linear regression model. The method also showed satisfactory results in terms of sensitivity, specificity, precision (intra- and inter-day CV from 2.4 to 10.2%), accuracy (from 91.0 to 111.7%), recovery as well as stability of the analytes under various conditions. The method is usually used in clinical practice in order to improve the SORA treatment for renal carcinoma, REGO treatment for colorectal cancer and both for hepatocellular carcinoma. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. [Comparison of chemical composition between fresh and processed Bufonis Venenum by UPLC-TQ-MS].

    Science.gov (United States)

    Wang, Zi-yue; Wang, Hong-lan; Zhou, Jing; Ma, Hong-yue; Gong, Yan; Yan, Wen-li; Qian, Da-wei

    2015-10-01

    Toad venom is the Bufo bufo gargarizans or B. melanostictus after the ears of the gland secretion, used in the treatment of various cancers in recent years. Research shows that the main anti-tumor components in bufadienolide. Bufadienolide have free type structure and conjunct type structure. To identify and clarify the difference between bufogenin and bufotoxin contained in Bufonis Venenum, which was from B. bufo gargarizans, an UPLC-TQ-MS method has been established. UPLC-TQ-MS method was used to identify and quantify the major bufadienolides in Bufonis Venenum. UPLC-TQ-MS assay with positive ion mode was performed on a Waters ACQUITY UPLC BEH C, (2.1 mm x 100 mm, 1.7 µm) with the mobile phase consisting of 0. 1% aqueous formic and acidacetonitrile in gradient elution at a flow rate of 0.4 mL · min⁻¹ and the column temperature was set at 35 °C. By comparing their retention time and high resolution mass data of Bufonis Venenum extracts, 37 effective components were primarily identified by MS/MS analysis in positive ion mode. Twenty-six of them were free-type bufadienolides (bufogenin), 11 of them were conjugated bufadienolides. There were significant differences in the main composition between fresh and processed Bufonis Venenum. The study found that the chemical composition of toad venom through great changes after processing, conjunct type content is much less, free type content as well change.

  14. Comparative study for toxic elements determination in air particulate reference material by INAA, CCT-ICP-MS, and ICP-MS

    International Nuclear Information System (INIS)

    Lim, J.M.; Lee, J.H.; Kim, K.H.; Moon, J.H.; Chung, Y.S.

    2005-01-01

    Although toxic elements are minor components in the atmospheric environment, they play a significant role as important marker for atmospheric science such as risk assessment, long-range transfer study, and source apportionment. Therefore, the techniques, which allow accurate and fast elemental analysis with a minimum pre-treatment, are very important. INAA has a main advantage of non-destruction of air particulate samples, while inductively Coupled plasma with mass spectrometry (ICP-MS) encounters the most significant difficulties in pre-treatment (digestion, fusion, and dilution) and polyatomic spectral interferences for interest toxic elements, Although INAA is still reference method, a number of factors (disadvantages of cost, complexity of the instruments, and scarcity of nuclear reactor) limit its applications. To date, the use of collision cell technology ICP-MS (CCT-ICP-MS) is recommended instead of typical ICP-MS for the analysis of the toxic elements; this is because CCT-ICP-MS technique prevents polyatomic spectral interferences despite of contamination and volatile effects. In this study, a number of toxic elements in reference material, NIST SRM 2783 (air particulate on filter media) were determined by INAA, CCT-ICP-MS, and ICP-MS. For both ICP methods, the filters were decomposed by microwave digestion with 5mL nitric acid. The analytical results by three methods were compared with certificated data; the INAA results showed the most accurate and precise data sets for all target elements among three methods. In detail, the deviation between analytical results and SRM's by INAA fell below 10% for all elements excluding As (14%), while those by CCT-ICP-MS were about 20%. For ICP-MS, the result does not agree with certificated data for several elements, because polyatomic spectral interference (due to 40 Ar 35 Cl, 40 Ar 23 Na, and 35 Cl 16 O) generate positive error of analytical result for As, Cu, and V. Based on our result, INAA is still one of the most

  15. A simple method for the analysis by MS/MS of underivatized amino acids on dry blood spots from newborn screening.

    Science.gov (United States)

    Wang, Chunyan; Zhang, Wenyan; Song, Fengrui; Liu, Zhiqiang; Liu, Shuying

    2012-05-01

    The analysis by electrospray-ionization tandem mass spectrometry of amino acids with butyl esterification and isotopically labeled internal standard is routine in newborn screening laboratories worldwide. In the present study, we established a direct analysis method of higher accuracy that uses a non-deuterated internal standard. The automatic sampler and the pump of an LC apparatus were used to inject sample and mobile phase to MS, but no LC column was needed. The dry blood spot (DBS) material was prepared at levels of low, medium and high concentration; the running time was 1 min. In parallel to the new procedure, we applied the established method to analyze nine amino acids on DBS of healthy newborns and phenylketonuria newborns. The newly proposed method of product ion confirmation scan along with multiple reaction monitoring resulted in a very accurate identification of each amino acid. Our innovative protocol had high sensitivity and specificity in the analysis of cases of suspected metabolic diseases.

  16. X-ray methods for the chemical characterization of atmospheric aerosols

    International Nuclear Information System (INIS)

    Jaklevic, J.M.; Thompson, A.C.

    1981-05-01

    The development and use of several x-ray methods for the chemical characterization of atmospherical aerosol particulate samples are described. These methods are based on the emission, absorption, and scattering of x-ray photons with emphasis on the optimization for the non-destructive analysis of dilute specimens. Techniques discussed include photon induced energy dispersive x-ray fluorescence, extended x-ray absorption fine structure spectroscopy using synchrotron radiation and high-rate x-ray powder diffractometry using a position-sensitive gas proportional counter. These x-ray analysis methods were applied to the measurement of the chemical compositions of size-segregated aerosol particulate samples obtained with dichotomous samplers. The advantages of the various methods for use in such measurements are described and results are presented. In many cases, the complementary nature of the analytical information obtained from the various measurements is an important factor in the characterization of the sample. For example, the multiple elemental analyses obtained from x-ray fluorescence can be used as a cross check on the major compounds observed by powder diffraction

  17. X. cap alpha. method with pseudopotentials

    Energy Technology Data Exchange (ETDEWEB)

    Szasz, L. (Fordham Univ., New York (USA). Dept. of Physics)

    1980-06-01

    The X..cap alpha.. method for an atom or molecule is transformed into an all-electron pseudopotential formalism. The equations of the X..cap alpha.. method are exactly transformed into pseudo-orbital equations and the resulting pseudopotentials are replaced by simple density-dependent potentials derived from Thomas-Fermi model. It is shown that the new formalism satisfies the virial theorem. As the first application, it is shown that the model explains the shell-structure of atoms by the property that the pseudo-orbitals for the (ns), (np), (nd), etc. electrons are, in a very good approximation, the solutions of the same equation and have their maxima at the same point thereby creating the peaks in the radial density characterizing the shell structure.

  18. Determination of rivaroxaban in patient's plasma samples by anti-Xa chromogenic test associated to High Performance Liquid Chromatography tandem Mass Spectrometry (HPLC-MS/MS).

    Science.gov (United States)

    Derogis, Priscilla Bento Matos; Sanches, Livia Rentas; de Aranda, Valdir Fernandes; Colombini, Marjorie Paris; Mangueira, Cristóvão Luis Pitangueira; Katz, Marcelo; Faulhaber, Adriana Caschera Leme; Mendes, Claudio Ernesto Albers; Ferreira, Carlos Eduardo Dos Santos; França, Carolina Nunes; Guerra, João Carlos de Campos

    2017-01-01

    Rivaroxaban is an oral direct factor Xa inhibitor, therapeutically indicated in the treatment of thromboembolic diseases. As other new oral anticoagulants, routine monitoring of rivaroxaban is not necessary, but important in some clinical circumstances. In our study a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was validated to measure rivaroxaban plasmatic concentration. Our method used a simple sample preparation, protein precipitation, and a fast chromatographic run. It was developed a precise and accurate method, with a linear range from 2 to 500 ng/mL, and a lower limit of quantification of 4 pg on column. The new method was compared to a reference method (anti-factor Xa activity) and both presented a good correlation (r = 0.98, p plasma samples for rivaroxaban measurement by HPLC-MS/MS without interferences. The chromogenic and HPLC-MS/MS methods were highly correlated and should be used as clinical tools for drug monitoring. The method was applied successfully in a group of 49 real-life patients, which allowed an accurate determination of rivaroxaban in peak and trough levels.

  19. Residue dynamics of pyraclostrobin in peanut and field soil by QuEChERS and LC-MS/MS.

    Science.gov (United States)

    Zhang, Fengzu; Wang, Lei; Zhou, Li; Wu, Di; Pan, Hongji; Pan, Canping

    2012-04-01

    A modified QuEChERS-LC-MS/MS (acronym of quick, easy, cheap, effective, rugged and safe-liquid chromatography tandem mass spectrometry) method for the analysis of pyraclostrobin residue in peanut and soil was developed and validated. Pyraclostrobin residue dynamics and final residues in supervised field trials at Good Agricultural Practice (GAP) conditions in peanut and soil were studied. The limits of quantitation (LOQs) for pyraclostrobin in soil, plant, shell and peanut samples were 0.00057, 0.00026, 0.003 and 0.0037 mg kg(-1), respectively. At fortification levels of 0.005, 0.05 and 0.5 mg kg(-1) in all samples, it was shown that recoveries ranged from 80.3% to 109.4% with relative standard deviations of 1.1-8.2% (n=5). The dissipation experiments showed the half-lives (T(1/2)) of pyraclostrobin in soil and plants were 13.1-16.5 days and 10.3-11.2 days, respectively. At pre-harvest intervals (PHI) of 14, 21 and 28 days, pyraclostrobin residue were 0.005-0.20 mg kg(-1) in soil, 0.006-0.27 mg kg(-1) in plants, below 0.053 mg kg(-1) in shells and not detectable in peanuts. Crown Copyright © 2011. Published by Elsevier Inc. All rights reserved.

  20. Characterization of toners and inkjets by laser ablation spectrochemical methods and Scanning Electron Microscopy-Energy Dispersive X-ray Spectroscopy

    International Nuclear Information System (INIS)

    Trejos, Tatiana; Corzo, Ruthmara; Subedi, Kiran; Almirall, José

    2014-01-01

    Detection and sourcing of counterfeit currency, examination of counterfeit security documents and determination of authenticity of medical records are examples of common forensic document investigations. In these cases, the physical and chemical composition of the ink entries can provide important information for the assessment of the authenticity of the document or for making inferences about common source. Previous results reported by our group have demonstrated that elemental analysis, using either Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry (LA-ICP-MS) or Laser Ablation Induced Breakdown Spectroscopy (LIBS), provides an effective, practical and robust technique for the discrimination of document substrates and writing inks with minimal damage to the document. In this study, laser-based methods and Scanning Electron Microscopy-Energy Dispersive X-Ray Spectroscopy (SEM-EDS) methods were developed, optimized and validated for the forensic analysis of more complex inks such as toners and inkjets, to determine if their elemental composition can differentiate documents printed from different sources and to associate documents that originated from the same printing source. Comparison of the performance of each of these methods is presented, including the analytical figures of merit, discrimination capability and error rates. Different calibration strategies resulting in semi-quantitative and qualitative analysis, comparison methods (match criteria) and data analysis and interpretation tools were also developed. A total of 27 black laser toners originating from different manufacturing sources and/or batches were examined to evaluate the discrimination capability of each method. The results suggest that SEM-EDS offers relatively poor discrimination capability for this set (∼ 70.7% discrimination of all the possible comparison pairs or a 29.3% type II error rate). Nonetheless, SEM-EDS can still be used as a complementary method of analysis since it has

  1. Characterization of toners and inkjets by laser ablation spectrochemical methods and Scanning Electron Microscopy-Energy Dispersive X-ray Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Trejos, Tatiana, E-mail: trejost@fiu.edu; Corzo, Ruthmara, E-mail: rcorz001@fiu.edu; Subedi, Kiran, E-mail: ksube001@fiu.edu; Almirall, José, E-mail: almirall@fiu.edu

    2014-02-01

    Detection and sourcing of counterfeit currency, examination of counterfeit security documents and determination of authenticity of medical records are examples of common forensic document investigations. In these cases, the physical and chemical composition of the ink entries can provide important information for the assessment of the authenticity of the document or for making inferences about common source. Previous results reported by our group have demonstrated that elemental analysis, using either Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry (LA-ICP-MS) or Laser Ablation Induced Breakdown Spectroscopy (LIBS), provides an effective, practical and robust technique for the discrimination of document substrates and writing inks with minimal damage to the document. In this study, laser-based methods and Scanning Electron Microscopy-Energy Dispersive X-Ray Spectroscopy (SEM-EDS) methods were developed, optimized and validated for the forensic analysis of more complex inks such as toners and inkjets, to determine if their elemental composition can differentiate documents printed from different sources and to associate documents that originated from the same printing source. Comparison of the performance of each of these methods is presented, including the analytical figures of merit, discrimination capability and error rates. Different calibration strategies resulting in semi-quantitative and qualitative analysis, comparison methods (match criteria) and data analysis and interpretation tools were also developed. A total of 27 black laser toners originating from different manufacturing sources and/or batches were examined to evaluate the discrimination capability of each method. The results suggest that SEM-EDS offers relatively poor discrimination capability for this set (∼ 70.7% discrimination of all the possible comparison pairs or a 29.3% type II error rate). Nonetheless, SEM-EDS can still be used as a complementary method of analysis since it has

  2. A simple LC-MS/MS method for quantitative analysis of underivatized neurotransmitters in rats urine: assay development, validation and application in the CUMS rat model.

    Science.gov (United States)

    Zhai, Xue-jia; Chen, Fen; Zhu, Chao-ran; Lu, Yong-ning

    2015-11-01

    Many amino acid neurotransmitters in urine are associated with chronic stress as well as major depressive disorders. To better understand depression, an analytical LC-MS/MS method for the simultaneous determination of 11 underivatized neurotransmitters (4-aminohippurate, 5-HIAA, glutamate, glutamine, hippurate, pimelate, proline, tryptophan, tyramine, tyrosine and valine) in a single analytical run was developed. The advantage of this method is the simple preparation in that there is no need to deconjugate the urine samples. The quantification range was 25-12,800 ng mL(-1) with >85.8% recovery for all analytes. The nocturnal urine concentrations of the 11 neurotransmitters in chronic unpredictable mild stress (CUMS) model rats and control group (n = 12) were analyzed. A series of significant changes in urinary excretion of neurotransmitters could be detected: the urinary glutamate, glutamine, hippurate and tyramine concentrations were significantly lower in the CUMS group. In addition, the urinary concentrations of tryptophan as well as tyrosine were significantly higher in chronically stressed rats. This method allows the assessment of the neurotransmitters associated with CUMS in rat urine in a single analytical run, making it suitable for implementation as a routine technique in depression research. Copyright © 2015 John Wiley & Sons, Ltd.

  3. A solid-phase microextraction GC/MS/MS method for rapid quantitative analysis of food and beverages for the presence of legally restricted biologically active flavorings.

    Science.gov (United States)

    Bousova, Katerina; Mittendorf, Klaus; Senyuva, Hamide

    2011-01-01

    A method was developed using automated headspace solid-phase microextraction coupled with GC/MS/MS to simultaneously determine the presence of seven biologically active flavoring substances whose levels of use in processed foods is controlled by statutory limits. The method can be applied to identify and quantify the presence of 1,2-benzopyrone (coumarin), beta-asarone, 1-allyl-4-methoxybenzene (estragole), menthofuran, 4-allyl-1 ,2-dimethoxybenzene (methyl eugenol), pulegone, and thujone at levels ranging from 0.5 to 3000 mg/kg. The method has been optimized and validated for three different generic food types categorized on the basis of composition and anticipated use levels of flavorings and food ingredients. The food categories are alcoholic and nonalcoholic beverages; semisolid processed foods (e.g., soups, sauces, confectionary, etc.); and solid foods (muesli, bakery products, etc.). The method is simple, inexpensive, and rapid, and eliminates the use of flammable and toxic solvents. There is no sample preparation, and using MSIMS, unequivocal confirmation of identification is achieved even in highly complex matrixes containing many potential interfering volatiles. The method precision for spiked samples ranged from 2 to 21%, with the greatest variability associated with solid matrixes. The LOD and LOQ values were well below 0.1 and 0.5 mg/kg, respectively, in all cases for individual substances, fulfilling requirements for enforcement purposes. The robustness of the method was demonstrated in a small survey of retail samples of four spirits, five flavored milks, three energy drinks, five liqueurs, five soups, 10 sauces, five herbal teas, and three breakfast cereals.

  4. Comparative studies of HPLC-fluorometry and LC/MS method for the determination of N-acetylneuraminic acid as a marker of deteriorated ophthalmic solutions.

    Science.gov (United States)

    Iwatsuka, Kinya; Yasueda, Shin-ichi; Bando, Eiji; Fujii, Hiroyuki; Terada, Takashi; Okubo, Hiroya; Iwamoto, Hiroki; Kinoshita, Mitsuhiro; Kakehi, Kazuaki

    2011-10-01

    Methods for determining the deterioration of ophthalmic solutions using both high-performance liquid chromatography (HPLC) with fluorescence detection and liquid chromatography coupled with selected ion monitoring mass spectrometry (LC/MS) are described. The methods are based on the determination of N-acetylneuraminic acid (NeuAc) released by the hydrolysis of foreign bodies that contaminate eye drops during use. The released NeuAc was either labeled with 1,2-diamino-4,5-methylenedioxybenzene (DMB) for fluorometric detection or detected without derivatization by mass spectrometry. The calibration curves for NeuAc showed good linearity between 1.2 ng/mL and 39 ng/mL for fluorometric HPLC and 5.0 ng/mL and 100 ng/mL for LC/MS, respectively. Detection limits for fluorometric HPLC and LC/MS were 0.20 ng/mL and 0.88 ng/mL, respectively. The NeuAc content of some model glycoproteins determined by LC/MS method were 62-78% of those determined by fluorometry. The differences are attributed to matrix effects but the LC/MS method afforded sufficiently high sensitivity that NeuAc in the foreign bodies could be determined in eight of nine test samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. A LC-MS/MS method for the determination of BADGE-related and BFDGE-related compounds in canned fish food samples based on the formation of [M+NH(4)](+) aducts.

    Science.gov (United States)

    Míguez, J; Herrero, C; Quintás, I; Rodríguez, C; Gigosos, P G; Mariz, O C

    2012-12-01

    A new and simple liquid chromatography tandem mass-spectrometry method for the determination of different bisphenol A (BPA) derivatives such as bisphenol A diglycidyl ether (BADGE), bisphenol F diglycidyl ether (BFDGE) and their reaction products with water and hydrochloric acid in different fish food products was developed. The extraction procedure and the chromatographic conditions were optimised for complex food matrices such as fish products. Food samples were homogenised and extracted with a 1:1 solution of acetonitrile-hexane, the solvent was eliminated in a N(2) stream and the extract was reconstituted with 0.5mL of a 0.01M solution of ammonium formate. The sample solution obtained was directly measured by LC-MS/MS without any further purification under the developed conditions. The use of a mobile phase composed by ammonium formate-methanol in a binary gradient mode produced [M+NH(4)](+) aducts for the different BADGEs and BFDGEs. These aduct's fragmentations were employed for the LC-MS/MS quantification of BPA derivatives in canned fish samples. The results of the validation were appropriate: the method was linear for BADGE and its hydrolysed derivatives up to 1000μgkg(-1), for the remaining compounds linearity achieved up to 100μgkg(-1). Quantification limits were in the range 2-10μgkg(-1). RSD (intra and inter-day) was 6-12% and the recovery was comprised between 89% and 109%. Under the optimised conditions, the chromatographic separation was performed in 8min per sample. The method was applied to the determination of BADGE, BFDGE and their reaction products in different samples of canned fish from Spanish origin. Migration results obtained were in compliance with the EU regulations. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. A fully validated bioanalytical method using an UHPLC-MS/MS system for quantification of DNA and RNA oxidative stress biomarkers.

    Science.gov (United States)

    Cervinkova, Barbora; Krcmova, Lenka Kujovska; Sestakova, Veronika; Solichova, Dagmar; Solich, Petr

    2017-05-01

    A new, rapid and effective ultra-high-performance liquid chromatography method with mass spectrometry detection is described for the separation and quantification of 8-hydroxy-2-deoxyguanosine, 8-hydroxyguanosine and creatinine in human urine. The present study uses an isotope-labelled internal standard ([ 15 N] 5 -8-hydroxy-2-deoxyguanosine), a BIO core-shell stationary phase and an isocratic elution of methanol and water. Sample preparation of human urine was performed by solid-phase extraction (SPE) on Oasis HLB cartridges with methanol/water 50:50 (v/v) elution. Extraction recoveries ranged from 98.1% to 109.2%. Biological extracts showed high short-term stability. Several aspects of this procedure make it suitable for both clinical and research purposes: a short elution time of less than 3.2 min, an intra-day precision of 2.5-8.9%, an inter-day precision of 3.4-8.7% and low limits of quantification (27.7 nM for 8-hydroxyguanosine, 6.0 nM for 8-hydroxy-2-deoxyguanosine). Finally, simultaneous analysis of DNA and RNA oxidative stress biomarkers is a useful tool for monitoring disease progression in neurodegenerative disorders and cancer. Graphical abstract UHPLC-MS/MS analysis of DNA and RNA oxidative stress biomarkers.

  7. Development and validation of a highly sensitive LC-ESI-MS/MS method for estimation of IIIM-MCD-211, a novel nitrofuranyl methyl piperazine derivative with potential activity against tuberculosis: Application to drug development.

    Science.gov (United States)

    Magotra, Asmita; Sharma, Anjna; Gupta, Ajai Prakash; Wazir, Priya; Sharma, Shweta; Singh, Parvinder Pal; Tikoo, Manoj Kumar; Vishwakarma, Ram A; Singh, Gurdarshan; Nandi, Utpal

    2017-08-15

    In the present study, a simple, sensitive, specific and rapid liquid chromatography (LC) tandem mass spectrometry (MS/MS) method was developed and validated according to the Food and Drug Administration (FDA) guidelines for estimation of IIIM-MCD-211 (a potent oral candidate with promising action against tuberculosis) in mice plasma using carbamazepine as internal standard (IS). Bioanalytical method consisted of one step protein precipitation for sample preparation followed by quantitation in LC-MS/MS using positive electrospray ionization technique (ESI) operating in multiple reaction monitoring (MRM) mode. Elution was achieved in gradient mode on High Resolution Chromolith RP-18e column with mobile phase comprised of acetonitrile and 0.1% (v/v) formic acid in water at the flow rate of 0.4mL/min. Precursor to product ion transitions (m/z 344.5/218.4 and m/z 237.3/194.2) were used to measure analyte and IS, respectively. All validation parameters were well within the limit of acceptance criteria. The method was successfully applied to assess the pharmacokinetics of the candidate in mice following oral (10mg/kg) and intravenous (IV; 2.5mg/kg) administration. It was also effectively used to quantitate metabolic stability of the compound in mouse liver microsomes (MLM) and human liver microsomes (HLM) followed by its in-vitro-in-vivo extrapolation. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Development and application of a quantitative method based on LC-QqQ MS/MS for determination of steviol glycosides in Stevia leaves.

    Science.gov (United States)

    Molina-Calle, M; Sánchez de Medina, V; Delgado de la Torre, M P; Priego-Capote, F; Luque de Castro, M D

    2016-07-01

    Stevia is a currently well-known plant thanks to the presence of steviol glycosides, which are considered as sweeteners obtained from a natural source. In this research, a method based on LC-MS/MS by using a triple quadrupole detector was developed for quantitation of 8 steviol glycosides in extracts from Stevia leaves. The ionization and fragmentation parameters for selected reaction monitoring were optimized. Detection and quantitation limits ranging from 0.1 to 0.5ng/mL and from 0.5 to 1ng/mL, respectively, were achieved: the lowest attained so far. The steviol glycosides were quantified in extracts from leaves of seven varieties of Stevia cultivated in laboratory, greenhouse and field. Plants cultivated in field presented higher concentration of steviol glycosides than those cultivated in greenhouse. Thus, the way of cultivation clearly influences the concentration of these compounds. The inclusion of branches together with leaves as raw material was also evaluated, showing that this inclusion modifies, either positively or negatively, the concentration of steviol glycosides. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Determination of 99Tc in fresh water using TRU resin by ICP-MS.

    Science.gov (United States)

    Guérin, Nicolas; Riopel, Remi; Kramer-Tremblay, Sheila; de Silva, Nimal; Cornett, Jack; Dai, Xiongxin

    2017-10-02

    Technetium-99 ( 99 Tc) determination at trace level by inductively coupled plasma mass spectrometry (ICP-MS) is challenging because there is no readily available appropriate Tc isotopic tracer. A new method using Re as a recovery tracer to determine 99 Tc in fresh water samples, which does not require any evaporation step, was developed. Tc(VII) and Re(VII) were pre-concentrated on a small anion exchange resin (AER) cartridge from one litre of water sample. They were then efficiently eluted from the AER using a potassium permanganate (KMnO 4 ) solution. After the reduction of KMnO 4 in 2 M sulfuric acid solution, the sample was passed through a small TRU resin cartridge. Tc(VII) and Re(VII) retained on the TRU resin were eluted using near boiling water, which can be directly used for the ICP-MS measurement. The results for method optimisation, validation and application were reported. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  10. Identification of the Chemical Constituents in Simiao Wan and Rat Plasma after Oral Administration by GC-MS and LC-MS

    Directory of Open Access Journals (Sweden)

    Yunshuang Fan

    2017-01-01

    Full Text Available Simiao Wan (SMW, an important multiherbal formula used in traditional Chinese medicine, is extensively used to treat rheumatoid arthritis. However, the knowledge of the bioactive components of SMW remains unclear. Thus, gas chromatography–mass spectrometry (GC-MS and liquid chromatography–mass spectrometry (LC-MS were used to analyze the chemical constituents of volatile and nonvolatile extracts of SMW, as well as its absorbed components in rat plasma after oral SMW administration. Identification of several compounds was enabled by comparison of retention times, MS spectra, and MS/MS spectral data with the standard substance and reference materials reported in the literature. In the volatile extracts, GC-MS identified 26 compounds in vitro, three of which observed in blood by GC-MS. In the nonvolatile extracts, LC-MS identified 49 compounds in SMW; 18 compounds containing 7 prototype compounds, 5 metabolites, and 6 unknown compounds were absorbed by blood. The proposed GC-MS and LC-MS method was appropriate not only for the rapid screening and identification of multiple components of an SMW extract but also for screening its bioactive constituents in vivo. The proposed method could be a promising tool for the quality control of other Chinese herbal medicines.

  11. Development of Chiral LC-MS Methods for small Molecules and Their Applications in the Analysis of Enantiomeric Composition and Pharmacokinetic Studies

    Energy Technology Data Exchange (ETDEWEB)

    Desai, Meera Jay [Iowa State Univ., Ames, IA (United States)

    2004-01-01

    The purpose of this research was to develop sensitive LC-MS methods for enantiomeric separation and detection, and then apply these methods for determination of enantiomeric composition and for the study of pharmacokinetic and pharmacodynamic properties of a chiral nutraceutical. Our first study, evaluated the use of reverse phase and polar organic mode for chiral LC-API/MS method development. Reverse phase methods containing high water were found to decrease ionization efficiency in electrospray, while polar organic methods offered good compatibility and low limits of detection with ESI. The use of lower flow rates dramatically increased the sensitivity by an order of magnitude. Additionally, for rapid chiral screening, the coupled Chirobiotic column afforded great applicability for LC-MS method development. Our second study, continued with chiral LC-MS method development in this case for the normal phase mode. Ethoxynonafluorobutane, a fluorocarbon with low flammability and no flashpoint, was used as a substitute solvent for hexane/heptane mobile phases for LC-APCI/MS. Comparable chromatographic resolutions and selectivities were found using ENFB substituted mobile phase systems, although, peak efficiencies were significantly diminished. Limits of detection were either comparable or better for ENFB-MS over heptane-PDA detection. The miscibility of ENFB with a variety of commonly used organic modifiers provided for flexibility in method development. For APCI, lower flow rates did not increase sensitivity as significantly as was previously found for ESI-MS detection. The chiral analysis of native amino acids was evaluated using both APCI and ESI sources. For free amino acids and small peptides, APCI was found to have better sensitivities over ESI at high flow rates. For larger peptides, however, sensitivity was greatly improved with the use of electrospray. Additionally, sensitivity was enhanced with the use of non-volatile additives, This optimized method was then

  12. A novel screening method for 64 new psychoactive substances and 5 amphetamines in blood by LC-MS/MS and application to real cases.

    Science.gov (United States)

    Vaiano, Fabio; Busardò, Francesco P; Palumbo, Diego; Kyriakou, Chrystalla; Fioravanti, Alessia; Catalani, Valeria; Mari, Francesco; Bertol, Elisabetta

    2016-09-10

    Identification and quantification of new psychoactive substances (NPS), both in biological and non-biological samples, represent a hard challenge for forensic toxicologists. NPS are increasingly emerging on illegal drug market. Many cases of co-consumption of NPS and other substances have also been reported. Hence, the development of analytical methods aiming at the detection of a broad-spectrum of compounds (NPS and "traditional" drugs) could be helpful. In this paper, a fully validated screening method in blood for the simultaneous detection of 69 substances, including 64 NPS (28 synthetic cannabinoids, 19 synthetic cathinones, 5 phenethylamines, 3 indanes, 2 piperazines, 2 tryptamines, 2 phencyclidine, methoxetamine, ketamine and its metabolite) and 5 amphetamines (amphetamine, methamphetamine, MDMA, MDA, 3,4-methylenedioxy-N-ethylamphetamine - MDEA-) by a dynamic multiple reaction monitoring analysis through liquid chromatography - tandem mass spectrometry (LC-MS/MS) is described. This method is very fast, easy to perform and cheap as it only requires the deproteinization of 200μL of blood sample with acetonitrile. The chromatographic separation is achieved with a C18 column. The analysis is very sensitive, with limits of quantification ranging from 0.1 to 0.5ng/mL. The method is linear from 1 to 100ng/mL and the coefficient of determination (R(2)) was always above 0.9900. Precision and accuracy were acceptable at any quality control level and recovery efficiency range was 72-110%. Matrix effects did not negatively affect the analytical sensitivity. This method was successfully applied to three real cases, allowing identification and quantification of: mephedrone and methamphetamine (post-mortem); ketamine, MDMA and MDA (post-mortem); AB-FUBINACA (ante-mortem). Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Validation and implementation of liquid chromatographic-mass spectrometric (LC-MS) methods for the quantification of tenofovir prodrugs.

    Science.gov (United States)

    Hummert, Pamela; Parsons, Teresa L; Ensign, Laura M; Hoang, Thuy; Marzinke, Mark A

    2018-04-15

    The nucleotide reverse transcriptase inhibitor tenofovir (TFV) is widely administered in a disoproxil prodrug form (tenofovir disoproxil fumarate, TDF) for HIV management and prevention. Recently, novel prodrugs tenofovir alafenamide fumarate (TAF) and hexadecyloxypropyl tenofovir (CMX157) have been pursued for HIV treatment while minimizing adverse effects associated with systemic TFV exposure. Dynamic and sensitive bioanalytical tools are required to characterize the pharmacokinetics of these prodrugs in systemic circulation. Two parallel methods have been developed, one to combinatorially quantify TAF and TFV, and a second method for CMX157 quantification, in plasma. K 2 EDTA plasma was spiked with TAF and TFV, or CMX157. Following the addition of isotopically labeled internal standards and sample extraction via solid phase extraction (TAF and TFV) or protein precipitation (CMX157), samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis. For TAF and TFV, separation occurred using a Zorbax Eclipse Plus C18 Narrow Bore RR, 2.1 × 50 mm, 3.5 μm column and analytes were detected on an API5000 mass analyzer; CMX157 was separated using a Kinetex C8, 2.1 × 50 mm, 2.6 μm column and quantified using an API4500 mass spectrometer. Methods were validated according to FDA Bioanalytical Method Validation guidelines. Analytical methods: were optimized for the multiplexed monitoring of TAF and TFV, and CMX157 in plasma. The lower limits of quantification (LLOQs) for TAF, TFV, and CMX157 were 0.03, 1.0, and 0.25 ng/mL, respectively. Calibration curves were generated via weighted linear regression of standards. Intra- and inter-assay precision and accuracy studies demonstrated %CVs ≤ 14.4% and %DEVs ≤ ± 7.95%, respectively. Stability and matrix effects studies were also performed. All results were acceptable and in accordance with the recommended guidelines for bioanalytical methods. Assays were also

  14. Pediatric MS

    Science.gov (United States)

    ... Pediatric MS Share this page Facebook Twitter Email Pediatric MS Pediatric MS Pediatric MS Support Pediatric Providers ... system through the Pediatric MS Support Group . Treating pediatric MS In 2018 the U.S. Food and Drug ...

  15. A method of coupling the Paternò-Büchi reaction with direct infusion ESI-MS/MS for locating the C[double bond, length as m-dash]C bond in glycerophospholipids.

    Science.gov (United States)

    Stinson, Craig A; Xia, Yu

    2016-06-21

    Tandem mass spectrometry (MS/MS) coupled with soft ionization is established as an essential platform for lipid analysis; however, determining high order structural information, such as the carbon-carbon double bond (C[double bond, length as m-dash]C) location, remains challenging. Recently, our group demonstrated a method for sensitive and confident lipid C[double bond, length as m-dash]C location determination by coupling online the Paternò-Büchi (PB) reaction with nanoelectrospray ionization (nanoESI) and MS/MS. Herein, we aimed to expand the scope of the PB reaction for lipid analysis by enabling the reaction with infusion ESI-MS/MS at much higher flow rates than demonstrated in the nanoESI setup (∼20 nL min(-1)). In the new design, the PB reaction was effected in a fused silica capillary solution transfer line, which also served as a microflow UV reactor, prior to ESI. This setup allowed PB reaction optimization and kinetics studies. Under optimized conditions, a maximum of 50% PB reaction yield could be achieved for a standard glycerophosphocholine (PC) within 6 s of UV exposure over a wide flow rate range (0.1-10 μL min(-1)). A solvent composition of 7 : 3 acetone : H2O (with 1% acid or base modifier) allowed the highest PB yields and good lipid ionization, while lower yields were obtained with an addition of a variety of organic solvents. Radical induced lipid peroxidation was identified to induce undesirable side reactions, which could be effectively suppressed by eliminating trace oxygen in the solution via N2 purge. Finally, the utility of coupling the PB reaction with infusion ESI-MS/MS was demonstrated by analyzing a yeast polar lipid extract where C[double bond, length as m-dash]C bond locations were revealed for 35 glycerophospholipids (GPs).

  16. Structural and magnetic properties of Mg-Zn ferrites (Mg1−xZnxFe2O4) prepared by sol-gel method

    International Nuclear Information System (INIS)

    Reyes-Rodríguez, Pamela Yajaira; Cortés-Hernández, Dora Alicia; Escobedo-Bocardo, José Concepción; Almanza-Robles, José Manuel; Sánchez-Fuentes, Héctor Javier; Jasso-Terán, Argentina; De León-Prado, Laura Elena; Méndez-Nonell, Juan; Hurtado-López, Gilberto Francisco

    2017-01-01

    In this study, the Mg 1−x Zn x Fe 2 O 4 nanoparticles (x=0–0.9) were prepared by sol-gel method. These ferrites exhibit an inverse spinel structure and the lattice parameter increases as the substitution of Zn 2+ ions is increased. At lower Zn content (0.1≤x≤0.5), saturation magnetization (Ms) increases, while it decreases at higher Zn content (x≥6). The remnant magnetization (0.17–2.0 emu/g) and coercive field (6.0–60 Oe) indicate a ferrimagnetic behavior. The average core diameter of selected ferrites is around 15 nm and the nanoparticles morphology is quasi spherical. The heating ability of some Mg 0.9 Zn 0.1 Fe 2 O 4 and Mg 0.7 Zn 0.3 Fe 2 O 4 aqueous suspensions indicates that the magnetic nanoparticles can increase the medium temperature up to 42 °C in a time less than 10 min - Highlights: • Magnetic nanoparticles of Mg 1−x Zn x Fe 2 O 4 were synthesized by sol-gel method. • Nanoparticles showing a single spinel crystalline structure were obtained. • Aqueous suspensions of Mg 0.7 Zn 0.3 Fe 2 O 4 and Mg 0.9 Zn 0.1 Fe 2 O 4 show heating ability.

  17. Application of an LC–MS/MS method for the analysis of amlodipine, valsartan and hydrochlorothiazide in polypill for a bioequivalence study

    Directory of Open Access Journals (Sweden)

    Jaivik V. Shah

    2017-10-01

    Full Text Available A sensitive and selective method has been proposed for the simultaneous determination of amlodipine (AML, valsartan (VAL and hydrochlorothiazide (HCTZ in human plasma by liquid chromatography–tandem mass spectrometry (LC–MS/MS. The analytes and their deuterated analogs were quantitatively extracted from 100 µL human plasma by solid phase extraction on Oasis HLB cartridges. The chromatographic separation of the analytes was achieved on a Chromolith RP18e (100 mm × 4.6 mm analytical column within 2.5 min. The resolution factor between AML and VAL, AML and HCTZ, and VAL and HCTZ was 2.9, 1.5 and 1.4, respectively, under isocratic conditions. The method was validated over a dynamic concentration range of 0.02–20.0 ng/mL for AML, 5.00–10,000 ng/mL for VAL and 0.20–200 ng/mL for HCTZ. Ion-suppression/enhancement effects were investigated by post-column infusion technique. The mean IS-normalized matrix factors for AML, VAL and HCTZ were 0.992, 0.994 and 0.998, respectively. The intra-batch and inter-batch precision (% CV across quality control levels was ≤ 5.56% and the recovery was in the range of 93.4%–99.6% for all the analytes. The method was successfully applied to a bioequivalence study of 5 mg AML + 160 mg VAL + 12.5 mg HCTZ tablet formulation (test and reference in 18 healthy Indian males under fasting. The mean log-transformed ratios of Cmax, AUC0–120h and AUC0-inf and their 90% CIs were within 90.2%–102.1%. The assay reproducibility was demonstrated by reanalysis of 90 incurred samples.

  18. Analysis of U-47700, a Novel Synthetic Opioid, in Human Urine by LC-MS-MS and LC-QToF.

    Science.gov (United States)

    Fleming, Steven W; Cooley, Justin C; Johnson, Leonard; Frazee, C Clinton; Domanski, Kristina; Kleinschmidt, Kurt; Garg, Uttam

    2017-04-01

    The illicit drug market has rapidly evolved from synthetic cannabinoids to cathinone derivatives and now a new emerging threat of synthetic opioids. These compounds were mostly developed by pharmaceutical companies during drug discovery. The new psychoactive substances are not routinely covered in drug screening and may go undetected. Recently fentanyl analogous, AH-7921, MT-45 and now U-47700 have been encountered in clinical and forensic casework. U-47700 is gaining popularity on drug user forms as a legal alternative to heroin. It is a µ-receptor agonist that is part of the trans-1-2-diamine opioid analgesic drug class developed by The Upjohn Company in an attempt to develop a non-addicting analgesic. A LC-MS-MS method was developed and validated to detect and quantify U-47700. Additional analysis was conducted with an LC-QToF to identify the presence of the parent drug and metabolites. A total of four cases have been evaluated by the LC-MS-MS methodology which has an analytical range of 1-1,250 ng/mL and limit of detection of 1 ng/mL. The concentration of U-47700 in urine specimens ranged from below the limit of quantification to 224 ng/mL. The ToF analysis detected the presence of suspected phase I demethylated metabolites that may assist future analysis of this compound. The prevalence of designer opioids in casework highlights the importance of analysis for new psychoactive substances. Traditional opiates/opioids were not detected in the presented cases, but the available case histories revealed an opioid toxidrome. These findings suggest that U-47700 drug may cause significant morbidity and mortality within the United States as an emerging drug threat. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Identification of alkyl dimethylbenzylammonium surfactants in water samples by solid-phase extraction followed by ion trap LC/MS and LC/MS/MS

    Science.gov (United States)

    Ferrer, I.; Furlong, E.T.

    2001-01-01

    A novel methodology was developed for the determination of alkyl (C12, C14, and C16) dimethylbenzylammonium chloride (benzalkonium chloride or BAC, Chemical Abstract Service number: 8001-54-5) in water samples. This method is based on solid-phase extraction (SPE) using polymeric cartridges, followed by high-performance liquid chromatography/ion trap mass spectrometry (LC/MS) and tandem mass spectrometry(MS/MS) detection, equipped with an electrospray interface in positive ion mode. Chromatographic separation was achieved for three BAC homologues by using a C18 column and a gradient of acetonitrile/10 millimolar aqueous ammonium formate. Total method recoveries were higher than 71% in different water matrices. The main ions observed by LC/MS were at mass-to-charge ratios (m/z) of 304, 332, and 360, which correspond to the molecular ions of the C12, C14, and C16 alkyl BAC, respectively. The unequivocal structural identification of these compounds in water samples was performed by LC/MS/MS after isolation and subsequent fragmentation of each molecular ion. The main fragmentation observed for the three different homologues corresponded to the loss of the toluyl group in the chemical structure, which leads to the fragment ions at m/z 212, 240, and 268 and a tropylium ion, characteristic of all homologues, at m/z 91. Detection limits for the methodology developed in this work were in the low nanogram-per-liter range. Concentration levels of BAC - ranging from 1.2 to 36.6 micrograms per liter - were found in surface-water samples collected downstream from different wastewater-treatment discharges, thus indicating its input and persistence through the wastewater-treatment process.

  20. Sample preparation method for ICP-MS measurement of 99Tc in a large amount of environmental samples

    International Nuclear Information System (INIS)

    Kondo, M.; Seki, R.

    2002-01-01

    Sample preparation for measurement of 99 Tc in a large amount of soil and water samples by ICP-MS has been developed using 95m Tc as a yield tracer. This method is based on the conventional method for a small amount of soil samples using incineration, acid digestion, extraction chromatography (TEVA resin) and ICP-MS measurement. Preliminary concentration of Tc has been introduced by co-precipitation with ferric oxide. The matrix materials in a large amount of samples were more sufficiently removed with keeping the high recovery of Tc than previous method. The recovery of Tc was 70-80% for 100 g soil samples and 60-70% for 500 g of soil and 500 L of water samples. The detection limit of this method was evaluated as 0.054 mBq/kg in 500 g soil and 0.032 μBq/L in 500 L water. The determined value of 99 Tc in the IAEA-375 (soil sample collected near the Chernobyl Nuclear Reactor) was 0.25 ± 0.02 Bq/kg. (author)

  1. Analysis Method for Pesticides Residues by GC/MS in Lebanese Apple

    International Nuclear Information System (INIS)

    Jaber, F.; Al Iskandarani, M.

    2008-01-01

    The apple's crop can be affected by many pests during the growing season, which requires careful monitoring. Both apple fruit and apple tree need to be treated by pesticides in order to protect them from pests. Such treatment often leads to the accumulation of stable pesticides inside the fruit. The local market provides a large variety of pesticides allowing farmers to use more than one active substance in order to protect their crop, often without proper advice. Monitoring pesticides on apples and other agricultural crops is the best way to protect consumers health from the hazards of pesticides residues. The development of new, rapid and effective method to analyze the multi pesticides residues at trace levels in apple samples is essential. This work describes the extraction procedure and the analytical method developed to detect the pesticide residues using the gas-chromatographic-mass spectrometric approach (GC-MS). The developed method was successfully applied to analyze apple samples collected from different Lebanese markets for a one year period in order to monitor the presence of pesticides and their stability in apple fruits during storage. (author)

  2. Chemical characterization of neonicotinoids in surface waters by high performance liquid chromatography with Tandem Mass Spectrometry (HPLC MS/MS)

    International Nuclear Information System (INIS)

    Amaral, Priscila Oliveira

    2017-01-01

    The present study aimed to develop a method for the determination and validation of a method for the identification and quantification of Neonicotinoids in surface waters collected in the Bauru region, in the state of São Paulo. The analytical techniques studied for the development of this method were the high performance liquid chromatography with tandem mass spectrometry (HPLC - MS / MS), gas chromatography with mass spectrometry (GC / MS) and gas chromatography with electron capture detector (GC / ECD). The class of pesticides Neonicotinoids was chosen for this work because it is related to a sudden disappearance of bees in colonies around the world. This phenomenon is known as Colony Collapse Disorder (CCD) and it is characterized by a rapid loss in the population of adult bees. The Neonicotinoids used in this study were the compounds Clothianidin, Imidacloprid and Thiamethoxam which were banned in their use as pesticides in Europe by Implementing Regulation No. 540/2011. The samples were concentrated using solid phase extraction (SPE) and liquid liquid extraction (LLE) techniques and injected into HPLC-MS / MS, GC / MS and GC / ECD. The GC / ECD and GC / MS techniques were not satisfactory for determination in the water matrix because the detection limit (10 mg L -1 ) is above the maximum allowed by the US Environmental Protection Agency (0.6 μg L -1 ). The HPLC - MS / MS technique using the multiple reaction monitoring (MRM) proved to be adequate for this study because it obtained quantification limits between 5.89 and 8.06 μg L -1 and a linearity between 0.9963 and 0.9999 for the three compounds. (author)

  3. Comprehensive comparison of in silico MS/MS fragmentation tools of the CASMI contest: database boosting is needed to achieve 93% accuracy.

    Science.gov (United States)

    Blaženović, Ivana; Kind, Tobias; Torbašinović, Hrvoje; Obrenović, Slobodan; Mehta, Sajjan S; Tsugawa, Hiroshi; Wermuth, Tobias; Schauer, Nicolas; Jahn, Martina; Biedendieck, Rebekka; Jahn, Dieter; Fiehn, Oliver

    2017-05-25

    In mass spectrometry-based untargeted metabolomics, rarely more than 30% of the compounds are identified. Without the true identity of these molecules it is impossible to draw conclusions about the biological mechanisms, pathway relationships and provenance of compounds. The only way at present to address this discrepancy is to use in silico fragmentation software to identify unknown compounds by comparing and ranking theoretical MS/MS fragmentations from target structures to experimental tandem mass spectra (MS/MS). We compared the performance of four publicly available in silico fragmentation algorithms (MetFragCL, CFM-ID, MAGMa+ and MS-FINDER) that participated in the 2016 CASMI challenge. We found that optimizing the use of metadata, weighting factors and the manner of combining different tools eventually defined the ultimate outcomes of each method. We comprehensively analysed how outcomes of different tools could be combined and reached a final success rate of 93% for the training data, and 87% for the challenge data, using a combination of MAGMa+, CFM-ID and compound importance information along with MS/MS matching. Matching MS/MS spectra against the MS/MS libraries without using any in silico tool yielded 60% correct hits, showing that the use of in silico methods is still important.

  4. UP-HILIC-MS/MS to Determine the Action Pattern of Penicillium sp. Dextranase

    Science.gov (United States)

    Yi, Lin; Sun, Xue; Du, Kenze; Ouyang, Yilan; Wu, Chengling; Xu, Naiyu; Linhardt, Robert J.; Zhang, Zhenqing

    2015-07-01

    Investigation of the action pattern of enzymes acting on carbohydrates is challenging, as both the substrate and the digestion products are complex mixtures. Dextran and its enzyme-derived oligosaccharides are widely used for many industrial applications. In this work, a new method relying on ultra-performance hydrophilic interaction liquid chromatography quadrupole time-of-flight tandem mass spectrometry (UP-HILIC- Q/TOF-MS/MS) was developed to analyze a complex mixture of dextran oligosaccharide products to determine the action pattern of dextranase. No derivatization of oligosaccharides was required and the impact of the α- and β-configurations of the native oligosaccharides on the chromatographic separation was eliminated. The 1→6, 1→3, 1→4 backbone linkages and the branch linkages of these oligosaccharides were all distinguished from diagnostic ions in their MS/MS spectra, including fragments corresponding to 0,2A, 0,3A, 0,4A, B-H2O, 2,5A, and 3,5A. The sequences of the oligosaccharide products were similarly established. Thus, the complex oligosaccharide mixtures in dextran digestion products were profiled and identified using this method. The more enzyme-resistant structures in dextran were established using much less sample, labor, time, and uncertainty than in previous studies. This method provides an efficient, sensitive, and straightforward way to monitor the entire process of digestion, establish the action pattern of the dextranase from Penicillium sp., and to support the proper industrial application of dextranase.

  5. Simultaneous quantitation of multiple contraceptive hormones in human serum by LC-MS/MS.

    Science.gov (United States)

    Blue, Steven W; Winchell, Andrea J; Kaucher, Amy V; Lieberman, Rachel A; Gilles, Christopher T; Pyra, Maria N; Heffron, Renee; Hou, Xuanlin; Coombs, Robert W; Nanda, Kavita; Davis, Nicole L; Kourtis, Athena P; Herbeck, Joshua T; Baeten, Jared M; Lingappa, Jairam R; Erikson, David W

    2018-04-01

    The objective was to develop a method to simultaneously quantify five commonly used hormonal contraceptives (HCs) and two endogenous sex steroids by liquid chromatography-tandem triple quadrupole mass spectrometry (LC-MS/MS) and apply this method to human serum samples. We developed a method to simultaneously analyze ethinyl estradiol (EE2), etonogestrel (ENG), levonorgestrel (LNG), medroxyprogesterone acetate (MPA) and norethisterone (NET), along with estradiol (E2) and progesterone (P4), in human serum for a Shimadzu Nexera-LCMS-8050 LC-MS/MS platform. We analyzed serum collected from women self-reporting use of oral contraceptives, contraceptive implants or injectable contraceptives (n=14) and normally cycling women using no HC (n=15) as well as pooled samples from women administered various HCs (ENG, n=6; LNG, n=14; MPA, n=7; NET, n=5). Limits of quantitation were 0.010ng/mL for E2, EE2 and P4; 0.020ng/mL for ENG, LNG and MPA; and 0.040ng/mL for NET. Precisions for all assays, as indicated by coefficient of variation, were less than or equal to 12.1%. Accuracies for all assays were in the range of 95%-108%. Endogenous hormone values obtained from analysis of human serum samples are in agreement with levels previously reported in the literature for normally cycling women as well as for women taking the appropriate HC. We have developed a robust, accurate and sensitive method for simultaneously analyzing commonly used contraceptive steroids and endogenous sex steroids in human serum. This analytical method can be used for quantitating contraceptive steroid levels in women for monitoring systemic exposure to determine drug interactions, nonadherence, misreporting and proper dosing. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Dried blood spot analysis of creatinine with LC-MS/MS in addition to immunosuppressants analysis

    NARCIS (Netherlands)

    Koster, Remco A.; Greijdanus, Ben; Alffenaar, Jan-Willem C.; Touw, Daan J.

    In order to monitor creatinine levels or to adjust the dosage of renally excreted or nephrotoxic drugs, the analysis of creatinine in dried blood spots (DBS) could be a useful addition to DBS analysis. We developed a LC-MS/MS method for the analysis of creatinine in the same DBS extract that was

  7. Rapid Quantification of Abscisic Acid by GC-MS/MS for Studies of Abiotic Stress Response.

    Science.gov (United States)

    Verslues, Paul E

    2017-01-01

    Drought and low water potential induce large increases in Abscisic Acid (ABA ) content of plant tissue. This increased ABA content is essential to regulate downstream stress resistance responses; however, the mechanisms regulating ABA accumulation are incompletely known. Thus, the ability to accurately quantify ABA at high throughput and low cost is important for plant stress research. We have combined and modified several previously published protocols to establish a rapid ABA analysis protocol using gas chromatography-tandem mass spectrometry (GC-MS/MS). Derivatization of ABA is performed with (trimethylsilyl)-diazomethane rather than the harder to prepare diazomethane. Sensitivity of the analysis is sufficient that small samples of low water potential treated Arabidopsis thaliana seedlings can be routinely analyzed in reverse genetic studies of putative stress regulators as well as studies of natural variation in ABA accumulation.

  8. Trends in statistical methods in articles published in Archives of Plastic Surgery between 2012 and 2017.

    Science.gov (United States)

    Han, Kyunghwa; Jung, Inkyung

    2018-05-01

    This review article presents an assessment of trends in statistical methods and an evaluation of their appropriateness in articles published in the Archives of Plastic Surgery (APS) from 2012 to 2017. We reviewed 388 original articles published in APS between 2012 and 2017. We categorized the articles that used statistical methods according to the type of statistical method, the number of statistical methods, and the type of statistical software used. We checked whether there were errors in the description of statistical methods and results. A total of 230 articles (59.3%) published in APS between 2012 and 2017 used one or more statistical method. Within these articles, there were 261 applications of statistical methods with continuous or ordinal outcomes, and 139 applications of statistical methods with categorical outcome. The Pearson chi-square test (17.4%) and the Mann-Whitney U test (14.4%) were the most frequently used methods. Errors in describing statistical methods and results were found in 133 of the 230 articles (57.8%). Inadequate description of P-values was the most common error (39.1%). Among the 230 articles that used statistical methods, 71.7% provided details about the statistical software programs used for the analyses. SPSS was predominantly used in the articles that presented statistical analyses. We found that the use of statistical methods in APS has increased over the last 6 years. It seems that researchers have been paying more attention to the proper use of statistics in recent years. It is expected that these positive trends will continue in APS.

  9. A comprehensive review of the published assays for the quantitation of the immunosuppressant drug mycophenolic acid and its glucuronidated metabolites in biological fluids.

    Science.gov (United States)

    Syed, Muzeeb; Srinivas, Nuggehally R

    2016-05-01

    Therapeutic use of mycophenolic acid (MPA) is steadily on the rise in combination with other immunosuppressant drugs in transplantation patients. The biotransformation of MPA resulted in the formation of glucuronide metabolites, MPAG and AcMPAG. There are a plethora of assays validated for the analysis of MPA alone or with MPAG/AcMPAG in various biological specimens including plasma/serum, urine, ultrafiltrate, saliva, PBMC, dried blood spots, tissue extract, tumor biopsies and vitreous humor. Based on the need for experimental work, a proper choice of the assay and internal standard may be made using the choices in the literature. While the chemical methods involving high-performance liquid chromatography (HPLC) or LC coupled with triple quadrupole mass spectrometry (LC-MS/MS) are popular, enzymatic assays, in spite of their higher bias, have been used for the routine drug monitoring of MPA. The objectives of the present review are: (a) to provide a focused systematic compilation of the HPLC or LC-MS/MS methods for MPA, MPAG and/or AcMPAG published in the last decade (2005 to current) to enable visual comparison of the methods; (b) to compare and contrast a few enzymatic assays with those of the chemical methods; and (c) to discuss relevant issues/limitations and perspectives on select assays under various subheadings. Copyright © 2016 John Wiley & Sons, Ltd.

  10. Identifying three ecological chemotypes of Xanthium strumarium glandular trichomes using a combined NMR and LC-MS method.

    Science.gov (United States)

    Chen, Fangfang; Hao, Fuhua; Li, Changfu; Gou, Junbo; Lu, Dayan; Gong, Fujun; Tang, Huiru; Zhang, Yansheng

    2013-01-01

    Xanthanolides, as the sesquiterpene lactones, are reportedly the major components for the pharmacological properties of X. strumarium L. species. Phytochemical studies indicated that the glandular structures on the surface of plant tissues would form the primary sites for the accumulation of this class of the compounds. As the interface between plants and their natural enemies, glandular trichomes may vary with respect to which of their chemicals are sequestered against different herbivores in different ecologies. However, to date, no data are available on the chemical characterisation of X. strumarium glandular cells. In this study, the trichome secretions of the X. strumarium species originating from nineteen unique areas across eleven provinces in China, were analysed by HPLC, LC-ESI-MS and NMR. For the first time three distinct chemotypes of X. strumarium glandular trichomes were discovered along with the qualitative and quantitative evaluations of their presence of xanthanolides; these were designated glandular cell Types I, II, and III, respectively. The main xanthanolides in Type I cells were 8-epi-xanthatin and xanthumin while no xanthatin was detected. Xanthatin, 8-epi-xanthatin, and xanthumin dominated in Type II cells with comparable levels of each being present. For Type III cells, significantly higher concentrations of 8-epi-xanthatin or xanthinosin (relative to xanthatin) were detected with xanthinosin only being observed in this type. Further research will focus on understanding the ecological and molecular mechanism causing these chemotype differences in X. strumarium glandular structures.

  11. Identifying three ecological chemotypes of Xanthium strumarium glandular trichomes using a combined NMR and LC-MS method.

    Directory of Open Access Journals (Sweden)

    Fangfang Chen

    Full Text Available Xanthanolides, as the sesquiterpene lactones, are reportedly the major components for the pharmacological properties of X. strumarium L. species. Phytochemical studies indicated that the glandular structures on the surface of plant tissues would form the primary sites for the accumulation of this class of the compounds. As the interface between plants and their natural enemies, glandular trichomes may vary with respect to which of their chemicals are sequestered against different herbivores in different ecologies. However, to date, no data are available on the chemical characterisation of X. strumarium glandular cells. In this study, the trichome secretions of the X. strumarium species originating from nineteen unique areas across eleven provinces in China, were analysed by HPLC, LC-ESI-MS and NMR. For the first time three distinct chemotypes of X. strumarium glandular trichomes were discovered along with the qualitative and quantitative evaluations of their presence of xanthanolides; these were designated glandular cell Types I, II, and III, respectively. The main xanthanolides in Type I cells were 8-epi-xanthatin and xanthumin while no xanthatin was detected. Xanthatin, 8-epi-xanthatin, and xanthumin dominated in Type II cells with comparable levels of each being present. For Type III cells, significantly higher concentrations of 8-epi-xanthatin or xanthinosin (relative to xanthatin were detected with xanthinosin only being observed in this type. Further research will focus on understanding the ecological and molecular mechanism causing these chemotype differences in X. strumarium glandular structures.

  12. A pilot mixed-methods evaluation of MS INFoRm: a self-directed fatigue management resource for individuals with multiple sclerosis.

    Science.gov (United States)

    Akbar, Nadine; Turpin, Karen; Petrin, Julie; Smyth, Penny; Finlayson, Marcia

    2018-06-01

    Fatigue management interventions for individuals with multiple sclerosis (MS) often feature structured programmes requiring repeated, in-person attendance that is not possible for all individuals. We sought to determine whether MS INFoRm, a self-directed fatigue management resource for individuals with MS, was worth further, more rigorous evaluation. Our indicators of worthiness were actual use of the resource by participants over 3 months, reductions in fatigue impact and increases in self-efficacy, and participant reports of changes in fatigue management knowledge and behaviours. This was a single-group, mixed-methods, before-after pilot study in individuals with MS reporting mild to moderate fatigue. Thirty-five participants were provided with MS INFoRm by a USB flash drive to use at home for 3 months, on their own volition. Twenty-three participants completed all standardized questionnaires, semi-structured interviews and study process measures. Participants reported actively using MS INFoRm over the 3-month study period (median total time spent using MS INFoRm=315 min) as well as significantly lower overall fatigue impact (Modified Fatigue Impact Scale: t=2.6, P=0.01), increased knowledge of MS fatigue (z=-2.8, P=0.01) and greater confidence in managing MS fatigue (z=-3.3, P=0.001). Individuals with significant reductions in fatigue impact also reported behavioural changes including tracking fatigue, better communication with others, greater awareness, improved quality of life and being more proactive. This study provides evidence that further rigorous evaluation of MS INFoRm, a self-directed resource for managing fatigue, is worth pursuing.

  13. The ethical hole at the centre of 'publish or perish'

    Czech Academy of Sciences Publication Activity Database

    Kravjar, J.; Hladík, Marek

    2016-01-01

    Roč. 430, 30 September 2016 (2016) ISSN 1756-297X Institutional support: RVO:68081758 Keywords : scholarly open-access publishing * predatory publishing * peer-review * publishing ethics Subject RIV: AC - Archeology, Anthropology, Ethnology http://www.universityworldnews.com/article.php?story=20160921112724448

  14. Studies on separation and pharmacokinetics of m-nisoldipine enantiomers in beagle dog plasma by LC/MS/MS.

    Science.gov (United States)

    Li, Min; Yuan, Lin; Li, Xiuqing; Zhi, Xuran; Sheng, Ning; Zhang, Lantong

    2013-11-01

    A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC/MS/MS) method was developed and validated for the separation and determination of m-nisoldipine enantiomers in beagle dog plasma. Samples were pretreated by a single-step protein precipitation with acetonitrile. After m-nisoldipine racemic administration to beagle dogs, samples of m-nisoldipine enantiomers in beagle dog plasma were separated and determined on a ULTRON ES-OVM column (150 × 4.6 mm, 5 μm) at 20°C with a mobile phase consisted of methanol-acetonitrile-ammonium acetate (pH 7.0; 2mM) (15:15:70, v/v/v) at a flow rate of 0.8 mL/min. Chromatograms were monitored at 237 nm, and the API 4000 triple quadrupole mass spectrometer was operated in multiple reaction monitoring (MRM) scan mode using ElectroSpray ionization (ESI) source. The good linearity (rs=0.9958 and rr=0.9983) were found in the range 0.25-20 ng/mL. The lower limit of quantification (LLOQ) obtained was 0.25 ng/mL (n=6). All the validation data, such as accuracy, precision, intra-day and inter-day repeatability, were within the required limits. The method was successfully applied to separation and pharmacokinetics of m-nisoldipine enantiomers in beagle dog plasma. The result of statistics analysis shows that there are no significant differences between R-(-)-m-nisoldipine and S-(+)-m-nisoldipine (p>0.05). The study provides necessary evidences for the research and new drug development of m-nisoldipine enantiomers. Copyright © 2013. Published by Elsevier B.V.

  15. Use of qualitative methods in published health services and management research: a 10-year review.

    Science.gov (United States)

    Weiner, Bryan J; Amick, Halle R; Lund, Jennifer L; Lee, Shoou-Yih Daniel; Hoff, Timothy J

    2011-02-01

    Over the past 10 years, the field of health services and management research has seen renewed interest in the use of qualitative research methods. This article examines the volume and characteristics of qualitative research articles published in nine major health services and management journals between 1998 and 2008. Qualitative research articles comprise 9% of research articles published in these journals. Although the publication rate of qualitative research articles has not kept pace with that of quantitative research articles, citation analysis suggests that qualitative research articles contribute comparably to the field's knowledge base. A wide range of policy and management topics has been examined using qualitative methods. Case study designs, interviews, and documentary sources were the most frequently used methods. Half of qualitative research articles provided little or no detail about key aspects the study's methods. Implications are discussed and recommendations are offered for promoting the publication of qualitative research.

  16. Progression in familial and nonfamilial MS

    NARCIS (Netherlands)

    Koch, Marcus; Uyttenboogaart, Maarten; Heerings, Marco; Heersema, Dorothea; Mostert, Jop; De Keyser, Jacques

    Objective To investigate whether the timing of secondary or primary progression is different between patients with familial and nonfamilial multiple sclerosis (MS). Methods Information on the family history of 313 patients with MS was taken from our prospective hospital-based database. We used

  17. Multiresidue determination and potential risks of emerging pesticides in aquatic products from Northeast China by LC-MS/MS.

    Science.gov (United States)

    Fu, Lei; Lu, Xianbo; Tan, Jun; Wang, Longxing; Chen, Jiping

    2018-01-01

    A simple method for determining 33 pesticides with a wide polarity range (logK ow 0.6-4.5) in aquatic products was developed based on LC-MS/MS. The target analytes included three types of widely used pesticides: insecticides, fungicides and herbicides. Based on the optimization of ultrasonic assisted extraction and GPC clean-up procedures, the matrix effect, extraction recoveries and LOD were improved distinctively. LOQ of this method was below 0.5ng/g for all pesticides, which is superior to values in the literature, and the matrix effect was reduced effectively (-14.7% to 7.5%). The method was successfully applied to investigate the pesticide residue levels of twenty-five samples including seven common kinds of fishes from Northeast China. The results showed that all targeted pesticides were present in the fish samples; however, their levels were low, except for atrazine, linuron, ethoprophos, tetrachlorvinphos, acetochlor and fenthion. Atrazine and linuron caught our attention because the concentrations of atrazine in fish samples from Liaoning province were in the range of 0.5-8ng/g (w/w) with mean concentration of 2.3ng/g, which were far above those of other pesticides. The levels of linuron were in the range of 0.6-6ng/g (mean concentration 2.8ng/g), which were the highest among all targeted pesticides in the Inner Mongolia. This is the first systematic investigation on the characteristics and levels of these pesticides in aquatic products from northeast China. Considering their toxicity and bioaccumulation, the potential risk of atrazine and linuron from consuming aquatic products should be paid more attention. Copyright © 2017. Published by Elsevier B.V.

  18. Development of an UPLC-MS/MS method for quantification of Avitinib (AC0010) and its five metabolites in human cerebrospinal fluid: Application to a study of the blood-brain barrier penetration rate of non-small cell lung cancer patients.

    Science.gov (United States)

    Wang, Weicong; Zheng, Xin; Wang, Hanping; Wang, Lu; Jiang, Ji; Hu, Pei

    2017-05-30

    Avitinib (AC0010) is a mutant-selective epidermal growth factor receptor tyrosine kinase inhibitors (EGFR-TKI), designed to be a targeted therapeutic agent for non-small cell lung cancer (NSCLC) patients harboring EGFR active and T790M resistant mutations. A rapid and sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the determination of Avitinib and its five metabolites (M1, M2, M4, M7, MII-6) in human cerebrospinal fluid (CSF). The samples were purified by protein precipitation and separated on a BEH C 18 column (2.1×50mm, 1.7μm). Electrospray ionization (ESI) in positive ion mode and multiple reaction monitoring (MRM) were used to monitor the ion transitions at m/z 488/257, 474/403, 504/487, 434/377, 490/405, 476/391. The results indicated that the method had excellent sensitivity and specificity. The linear range covered from 0.05 to 50ng/mL for Avitinib, M1, M4, M7, and MII-6, and from 0.01 to 10ng/mL for M2. Intra-day and inter-day precisions (in terms of% RSD) were all <15% and the accuracies (in terms of% RE) were within the range of ±15%. The lower limit of quantification (LLOQ), matrix effect, extraction recovery, stability and dilution integrity were also validated and satisfied with the criteria of validation. Finally, the method was successfully applied to a blood-brain barrier (BBB) penetration rate research of NSCLC patients after an oral administration of Avitinib. Copyright © 2017. Published by Elsevier B.V.

  19. Publishing: The Creative Business.

    Science.gov (United States)

    Bohne, Harald; Van Ierssel, Harry

    This book offers guidelines to emerging and would-be publishers, whether they plan to enter publishing as a career, a sideline, or a diversion. It stresses the business aspects of publishing and emphasizes the major housekeeping functions encountered in the business, except methods of sales and distribution. Contents include "The Mechanics of…

  20. Quantitation of dialkyl phosphate metabolites of organophosphate pesticides in human urine using GC-MS-MS with isotopic internal standards.

    Science.gov (United States)

    Bravo, Roberto; Driskell, William J; Whitehead, Ralph D; Needham, Larry L; Barr, Dana B

    2002-01-01

    Human exposure to organophosphate pesticides can be estimated from the presence of urinary metabolites. An isotope-dilution gas chromatography-tandem mass spectrometry (GC-MS-MS) method was developed for quantitating the six dialkyl phosphate urinary metabolites of at least 29 organophosphate pesticides. Urine samples were spiked with stable isotope analogues of the dialkyl phosphates, evaporated using azeotropic distillation, followed by chemical derivatization of the metabolites to their respective chloropropyl phosphate esters. The chloropropyl phosphate esters were concentrated and then analyzed using GC-MS-MS. The limits of detection (LODs) of the method were in the low-to-mid picogram-per-milliliter range (parts per trillion) with coefficients of variation of less than 20%. The use of stable isotope analogues as internal standards for each of these metabolites allows for the highest degree of accuracy and precision. Additionally, the low LODs allow the use of this method in general population studies.

  1. Optimization and Comparison of ESI and APCI LC-MS/MS Methods: A Case Study of Irgarol 1051, Diuron, and their Degradation Products in Environmental Samples

    Science.gov (United States)

    Maragou, Niki C.; Thomaidis, Nikolaos S.; Koupparis, Michael A.

    2011-10-01

    A systematic and detailed optimization strategy for the development of atmospheric pressure ionization (API) LC-MS/MS methods for the determination of Irgarol 1051, Diuron, and their degradation products (M1, DCPMU, DCPU, and DCA) in water, sediment, and mussel is described. Experimental design was applied for the optimization of the ion sources parameters. Comparison of ESI and APCI was performed in positive- and negative-ion mode, and the effect of the mobile phase on ionization was studied for both techniques. Special attention was drawn to the ionization of DCA, which presents particular difficulty in API techniques. Satisfactory ionization of this small molecule is achieved only with ESI positive-ion mode using acetonitrile in the mobile phase; the instrumental detection limit is 0.11 ng/mL. Signal suppression was qualitatively estimated by using purified and non-purified samples. The sample preparation for sediments and mussels is direct and simple, comprising only solvent extraction. Mean recoveries ranged from 71% to 110%, and the corresponding (%) RSDs ranged between 4.1 and 14%. The method limits of detection ranged between 0.6 and 3.5 ng/g for sediment and mussel and from 1.3 to 1.8 ng/L for sea water. The method was applied to sea water, marine sediment, and mussels, which were obtained from marinas in Attiki, Greece. Ion ratio confirmation was used for the identification of the compounds.

  2. The flexibility of a generic LC-MS/MS method for the quantitative analysis of therapeutic proteins based on human immunoglobulin G and related constructs in animal studies.

    Science.gov (United States)

    Lanshoeft, Christian; Wolf, Thierry; Walles, Markus; Barteau, Samuel; Picard, Franck; Kretz, Olivier; Cianférani, Sarah; Heudi, Olivier

    2016-11-30

    An increasing demand of new analytical methods is associated with the growing number of biotherapeutic programs being prosecuted in the pharmaceutical industry. Whilst immunoassay has been the standard method for decades, a great interest in assays based on liquid chromatography tandem mass spectrometry (LC-MS/MS) is evolving. In this present work, the development of a generic method for the quantitative analysis of therapeutic proteins based on human immunoglobulin G (hIgG) in rat serum is reported. The method is based on four generic peptides GPSVFPLAPSSK (GPS), TTPPVLDSDGSFFLYSK (TTP), VVSVLTVLHQDWLNGK (VVS) and FNWYVDGVEVHNAK (FNW) originating from different parts of the fraction crystallizable (Fc) region of a reference hIgG1 (hIgG1A). A tryptic pellet digestion of rat serum spiked with hIgG1A and a stable isotope labeled protein (hIgG1B) used as internal standard (ISTD) was applied prior LC-MS/MS analysis. The upper limit of quantification was at 1000μg/mL. The lower limit of quantitation was for GPS, TTP and VVS at 1.00μg/mL whereas for FNW at 5.00μg/mL. Accuracy and precision data met acceptance over three days. The presented method was further successfully applied to the quantitative analysis of other hIgG1s (hIgG1C and hIgG1D) and hIgG4-based therapeutic proteins on spiked quality control (QC) samples in monkey and rat serum using calibration standards (Cs) prepared with hIgG1A in rat serum. In order to extend the applicability of our generic approach, a bispecific-bivalent hIgG1 (bb-hIgG1) and two lysine conjugated antibody-drug conjugates (ADC1 and ADC2) were incorporated as well. The observed values on spiked QC samples in monkey serum were satisfactory with GPS for the determination of bb-hIgG1 whereas the FNW and TTP peptides were suitable for the ADCs. Moreover, comparable mean concentration-time profiles were obtained from monkeys previously dosed intravenously with ADC2 measured against Cs samples prepared either with hIgG1A in rat serum

  3. Structure Annotation and Quantification of Wheat Seed Oxidized Lipids by High-Resolution LC-MS/MS.

    Science.gov (United States)

    Riewe, David; Wiebach, Janine; Altmann, Thomas

    2017-10-01

    Lipid oxidation is a process ubiquitous in life, but the direct and comprehensive analysis of oxidized lipids has been limited by available analytical methods. We applied high-resolution liquid chromatography-mass spectrometry (LC-MS) and tandem mass spectrometry (MS/MS) to quantify oxidized lipids (glycerides, fatty acids, phospholipids, lysophospholipids, and galactolipids) and implemented a platform-independent high-throughput-amenable analysis pipeline for the high-confidence annotation and acyl composition analysis of oxidized lipids. Lipid contents of 90 different naturally aged wheat ( Triticum aestivum ) seed stocks were quantified in an untargeted high-resolution LC-MS experiment, resulting in 18,556 quantitative mass-to-charge ratio features. In a posthoc liquid chromatography-tandem mass spectrometry experiment, high-resolution MS/MS spectra (5 mD accuracy) were recorded for 8,957 out of 12,080 putatively monoisotopic features of the LC-MS data set. A total of 353 nonoxidized and 559 oxidized lipids with up to four additional oxygen atoms were annotated based on the accurate mass recordings (1.5 ppm tolerance) of the LC-MS data set and filtering procedures. MS/MS spectra available for 828 of these annotations were analyzed by translating experimentally known fragmentation rules of lipids into the fragmentation of oxidized lipids. This led to the identification of 259 nonoxidized and 365 oxidized lipids by both accurate mass and MS/MS spectra and to the determination of acyl compositions for 221 nonoxidized and 295 oxidized lipids. Analysis of 15-year aged wheat seeds revealed increased lipid oxidation and hydrolysis in seeds stored in ambient versus cold conditions. © 2017 The author(s). All Rights Reserved.

  4. Green and efficient sample preparation method for the determination of catalyst residues in margarine by ICP-MS.

    Science.gov (United States)

    Hartwig, Carla Andrade; Pereira, Rodrigo Mendes; Novo, Diogo La Rosa; Oliveira, Dirce Taina Teixeira; Mesko, Marcia Foster

    2017-11-01

    Responding to the need for green and efficient methods to determine catalyst residues with suitable precision and accuracy in samples with high fat content, the present work evaluates a microwave-assisted ultraviolet digestion (MW-UV) system for margarines and subsequent determination of Ni, Pd and Pt using inductively coupled plasma mass spectrometry (ICP-MS). It was possible to digest up to 500mg of margarine using only 10mL of 4molL -1 HNO 3 with a digestion efficiency higher than 98%. This allowed the determination of catalyst residues using the ICP-MS and free of interferences. For this purpose, the following experimental parameters were evaluated: concentration of digestion solution, sample mass and microwave irradiation program. The residual carbon content was used as a parameter to evaluate the efficiency of digestion and to select the most suitable experimental conditions. The accuracy evaluation was performed by recovery tests using a standard solution and certified reference material, and recoveries ranging from 94% to 99% were obtained for all analytes. The limits of detection for Ni, Pd and Pt using the proposed method were 35.6, 0.264 and 0.302ngg -1 , respectively. When compared to microwave-assisted digestion (MW-AD) in closed vessels using concentrated HNO 3 (used as a reference method for sample digestion), the proposed MW-UV could be considered an excellent alternative for the digestion of margarine, as this method requires only a diluted nitric acid solution for efficient digestion. In addition, MW-UV provides appropriate solutions for further ICP-MS determination with suitable precision (relative standard deviation < 7%) and accuracy for all evaluated analytes. The proposed method was applied to margarines from different brands produced in Brazil, and the concentration of catalyst residues was in agreement with the current legislation or recommendations. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Identifications and Photometric Redshifts of the 2 Ms Chandra Deep Field-South Sources

    Science.gov (United States)

    Luo, B.; Brandt, W. N.; Xue, Y. Q.; Brusa, M.; Alexander, D. M.; Bauer, F. E.; Comastri, A.; Koekemoer, A.; Lehmer, B. D.; Mainieri, V.; Rafferty, D. A.; Schneider, D. P.; Silverman, J. D.; Vignali, C.

    2010-04-01

    We present reliable multiwavelength identifications and high-quality photometric redshifts for the 462 X-ray sources in the ≈2 Ms Chandra Deep Field-South (CDF-S) survey. Source identifications are carried out using deep optical-to-radio multiwavelength catalogs, and are then combined to create lists of primary and secondary counterparts for the X-ray sources. We identified reliable counterparts for 442 (95.7%) of the X-ray sources, with an expected false-match probability of ≈ 6.2%; we also selected four additional likely counterparts. The majority of the other 16 X-ray sources appear to be off-nuclear sources, sources associated with galaxy groups and clusters, high-redshift active galactic nuclei (AGNs), or spurious X-ray sources. A likelihood-ratio method is used for source matching, which effectively reduces the false-match probability at faint magnitudes compared to a simple error-circle matching method. We construct a master photometric catalog for the identified X-ray sources including up to 42 bands of UV-to-infrared data, and then calculate their photometric redshifts (photo-z's). High accuracy in the derived photo-z's is accomplished owing to (1) the up-to-date photometric data covering the full spectral energy distributions (SEDs) of the X-ray sources, (2) more accurate photometric data as a result of source deblending for ≈10% of the sources in the infrared bands and a few percent in the optical and near-infrared bands, (3) a set of 265 galaxy, AGN, and galaxy/AGN hybrid templates carefully constructed to best represent all possible SEDs, (4) the Zurich Extragalactic Bayesian Redshift Analyzer used to derive the photo-z's, which corrects the SED templates to best represent the SEDs of real sources at different redshifts and thus improves the photo-z quality. The reliability of the photo-z's is evaluated using the subsample of 220 sources with secure spectroscopic redshifts. We achieve an accuracy of |Δz|/(1 + z) ≈ 1% and an outlier [with |

  6. A Novel Rapid MALDI-TOF-MS-Based Method for Measuring Urinary Globotriaosylceramide in Fabry Patients

    Science.gov (United States)

    Alharbi, Fahad J.; Geberhiwot, Tarekegn; Hughes, Derralynn A.; Ward, Douglas G.

    2016-04-01

    Fabry disease is an X-linked lysosomal storage disorder caused by deficiency of α-galactosidase A, resulting in the accumulation of glycosphingolipids in various organs. Globotriaosylceramide (Gb3) and its isoforms and analogues have been identified and quantified as biomarkers of disease severity and treatment efficacy. The current study aimed to establish rapid methods for urinary Gb3 extraction and quantitation. Urine samples from 15 Fabry patients and 21 healthy control subjects were processed to extract Gb3 by mixing equal volumes of urine, methanol containing an internal standard, and chloroform followed by sonication and centrifugation. Thereafter, the lower phase was analyzed by MALDI-TOF MS and the relative peak areas of the internal standard and four major species of Gb3 determined. The results showed high reproducibility with intra- and inter-assay coefficients variation of 9.9% and 13.7%, respectively. The limit of detection was 0.15 ng/μL and the limit of quantitation was 0.30 ng/μL. Total urinary Gb3 levels in both genders of classic Fabry patients were significantly higher than in healthy controls (p < 0.0001). Gb3 levels in Fabry males were higher than in Fabry females (p = 0.08). We have established a novel assay for urinary total Gb3 that takes less than 15 min from start to finish.

  7. A model independent method to deconvolve hard X-ray spectra

    International Nuclear Information System (INIS)

    Polcaro, V.F.; Bazzano, A.; Ubertini, P.; La Padula, C.

    1984-01-01

    A general purpose method to deconvolve the energy spectra detected by means of the use of a hard X-ray telescope is described. The procedure does not assume any form of input spectrum and the observed energy loss spectrum is directly deconvolved into the incident photon spectrum, the form of which can be determined independently of physical interpretation of the data. Deconvolution of the hard X-ray spectrum of Her X-1, detected during the HXR 81M experiment, by the method independent method is presented. (orig.)

  8. The Evolution of Normal Galaxy X-Ray Emission Through Cosmic History: Constraints from the 6 MS Chandra Deep Field-South

    Science.gov (United States)

    Lehmer, B. D.; Basu-Zych, A. R.; Mineo, S.; Brandt, W. N.; Eurfrasio, R. T.; Fragos, T.; Hornschemeier, A. E.; Lou, B.; Xue, Y. Q.; Bauer, F. E.; hide

    2016-01-01

    We present measurements of the evolution of normal-galaxy X-ray emission from z (is) approx. 0-7 using local galaxies and galaxy samples in the approx. 6 Ms Chandra Deep Field-South (CDF-S) survey. The majority of the CDF-S galaxies are observed at rest-frame energies above 2 keV, where the emission is expected to be dominated by X-ray binary (XRB) populations; however, hot gas is expected to provide small contributions to the observed-frame (is) less than 1 keV emission at z (is) less than 1. We show that a single scaling relation between X-ray luminosity (L(sub x)) and star-formation rate (SFR) literature, is insufficient for characterizing the average X-ray emission at all redshifts. We establish that scaling relations involving not only SFR, but also stellar mass and redshift, provide significantly improved characterizations of the average X-ray emission from normal galaxy populations at z (is) approx. 0-7. We further provide the first empirical constraints on the redshift evolution of X-ray emission from both low-mass XRB (LMXB) and high-mass XRB (HMXB) populations and their scalings with stellar mass and SFR, respectively. We find L2 -10 keV(LMXB)/stellar mass alpha (1+z)(sub 2-3) and L2 -10 keV(HMXB)/SFR alpha (1+z), and show that these relations are consistent with XRB population-synthesis model predictions, which attribute the increase in LMXB and HMXB scaling relations with redshift as being due to declining host galaxy stellar ages and metallicities, respectively. We discuss how emission from XRBs could provide an important source of heating to the intergalactic medium in the early universe, exceeding that of active galactic nuclei.

  9. Identification and quantification of cardiac glycosides in blood and urine samples by HPLC/MS/MS.

    Science.gov (United States)

    Guan, F; Ishii, A; Seno, H; Watanabe-Suzuki, K; Kumazawa, T; Suzuki, O

    1999-09-15

    Cardiac glycosides (CG) are of forensic importance because of their toxicity and the fact that very limited methods are available for identification of CG in biological samples. In this study, we have developed an identification and quantification method for digoxin, digitoxin, deslanoside, digoxigenin, and digitoxigenin by high-performance liquid chromatography tandem mass spectrometry (HPLC/MS/MS). CG formed abundant [M + NH4]+ ions and much less abundant [M + H]+ ions as observed with electrospray ionization (ESI) source and ammonium formate buffer. Under mild conditions for collision-induced dissociation (CID), each [M + NH4]+ ion fragmented to produce a dominant daughter ion, which was essential to the sensitive method of selected reaction monitoring (SRM) quantification of CG achieved in this study. SRM was compared with selected ion monitoring (SIM) regarding the effects of sample matrixes on the methodology. SRM produced lower detection limits with biological samples than SIM, while both methods produced equal detection limits with CG standards. On the basis of the HPLC/MS/MS results for CG, we have proposed some generalized points for conducting sensitive SRM measurements, in view of the property of analytes as well as instrumental conditions such as the type of HPLC/MS interface and CID parameters. Analytes of which the molecular ion can produce one abundant daughter ion with high yield under CID conditions may be sensitively measured by SRM. ESI is the most soft ionization source developed so far and can afford formation of the fragile molecular ions that are necessary for sensitive SRM detection. Mild CID conditions such as low collision energy and low pressure of collision gas favor production of an abundant daughter ion that is essential to sensitive SRM detection. This knowledge may provide some guidelines for conducting sensitive SRM measurements of very low concentrations of drugs or toxicants in biological samples.

  10. CANDELS/GOODS-S, CDFS, and ECDFS: photometric redshifts for normal and X-ray-detected galaxies

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Li-Ting; Salvato, Mara; Nandra, Kirpal; Brusa, Marcella; Bender, Ralf; Buchner, Johannes; Brightman, Murray; Georgakakis, Antonis [Max-Planck-Institut für extraterrestrische Physik, Giessenbachstrasse, D-85748 Garching (Germany); Donley, Jennifer L. [Los Alamos National Laboratory, Los Alamos, NM (United States); Kocevski, Dale D. [Department of Physics and Astronomy, University of Kentucky, Lexington, KY 40506 (United States); Guo, Yicheng; Barro, Guillermo; Faber, Sandra M. [UCO/Lick Observatory, Department of Astronomy and Astrophysics, University of California, Santa Cruz, CA (United States); Hathi, Nimish P. [Aix Marseille Université, CNRS, LAM (Laboratoire d' Astrophysique de Marseille) UMR 7326, F-13388 Marseille (France); Rangel, Cyprian [Astrophysics Group, Imperial College London, Blackett Laboratory, Prince Consort Road, London SW7 2AZ (United Kingdom); Willner, S. P.; Ashby, Matthew L. N. [Harvard-Smithsonian Center for Astrophysics, Cambridge, MA (United States); Budavári, Tamás; Szalay, Alexander S. [Department of Physics and Astronomy, The Johns Hopkins University, Baltimore, MD (United States); Dahlen, Tomas [Space Telescope Science Institute, Baltimore, MD (United States); and others

    2014-11-20

    We present photometric redshifts and associated probability distributions for all detected sources in the Extended Chandra Deep Field South (ECDFS). This work makes use of the most up-to-date data from the Cosmic Assembly Near-IR Deep Legacy Survey (CANDELS) and the Taiwan ECDFS Near-Infrared Survey (TENIS) in addition to other data. We also revisit multi-wavelength counterparts for published X-ray sources from the 4 Ms CDFS and 250 ks ECDFS surveys, finding reliable counterparts for 1207 out of 1259 sources (∼96%). Data used for photometric redshifts include intermediate-band photometry deblended using the TFIT method, which is used for the first time in this work. Photometric redshifts for X-ray source counterparts are based on a new library of active galactic nuclei/galaxy hybrid templates appropriate for the faint X-ray population in the CDFS. Photometric redshift accuracy for normal galaxies is 0.010 and for X-ray sources is 0.014 and outlier fractions are 4% and 5.2%, respectively. The results within the CANDELS coverage area are even better, as demonstrated both by spectroscopic comparison and by galaxy-pair statistics. Intermediate-band photometry, even if shallow, is valuable when combined with deep broadband photometry. For best accuracy, templates must include emission lines.

  11. CANDELS/GOODS-S, CDFS, and ECDFS: photometric redshifts for normal and X-ray-detected galaxies

    International Nuclear Information System (INIS)

    Hsu, Li-Ting; Salvato, Mara; Nandra, Kirpal; Brusa, Marcella; Bender, Ralf; Buchner, Johannes; Brightman, Murray; Georgakakis, Antonis; Donley, Jennifer L.; Kocevski, Dale D.; Guo, Yicheng; Barro, Guillermo; Faber, Sandra M.; Hathi, Nimish P.; Rangel, Cyprian; Willner, S. P.; Ashby, Matthew L. N.; Budavári, Tamás; Szalay, Alexander S.; Dahlen, Tomas

    2014-01-01

    We present photometric redshifts and associated probability distributions for all detected sources in the Extended Chandra Deep Field South (ECDFS). This work makes use of the most up-to-date data from the Cosmic Assembly Near-IR Deep Legacy Survey (CANDELS) and the Taiwan ECDFS Near-Infrared Survey (TENIS) in addition to other data. We also revisit multi-wavelength counterparts for published X-ray sources from the 4 Ms CDFS and 250 ks ECDFS surveys, finding reliable counterparts for 1207 out of 1259 sources (∼96%). Data used for photometric redshifts include intermediate-band photometry deblended using the TFIT method, which is used for the first time in this work. Photometric redshifts for X-ray source counterparts are based on a new library of active galactic nuclei/galaxy hybrid templates appropriate for the faint X-ray population in the CDFS. Photometric redshift accuracy for normal galaxies is 0.010 and for X-ray sources is 0.014 and outlier fractions are 4% and 5.2%, respectively. The results within the CANDELS coverage area are even better, as demonstrated both by spectroscopic comparison and by galaxy-pair statistics. Intermediate-band photometry, even if shallow, is valuable when combined with deep broadband photometry. For best accuracy, templates must include emission lines.

  12. Análise de fármacos em águas por SPE-UPLC-ESI-MS/MS

    Directory of Open Access Journals (Sweden)

    Vanessa de Jesus Gaffney

    2014-01-01

    Full Text Available A method was developed for the analysis of 31 pharmaceutical compounds in Lisbon's drinking water system, using solid-phase extraction (SPE and ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS. The method was validated through estimation of the linearity range, method detection and quantification limits, matrix effects, precision and accuracy. The method detection and quantification limit ranges were 0.009-10 and 0.03-33 ng/L, respectively. Analytes were quantified in water samples collected from the EPAL (Empresa Portuguesa das Águas Livres S.A. supply system. Carbamazepine, atenolol, sulfadiazine, sulfamethazine, sulfapyridine, sulfamethoxazole, acetaminophen, caffeine and erythromycin were quantified in the analysed samples.

  13. A simple LC-MS/MS method facilitated by salting-out assisted liquid-liquid extraction to simultaneously determine trans-resveratrol and its glucuronide and sulfate conjugates in rat plasma and its application to pharmacokinetic assay.

    Science.gov (United States)

    Qiu, Zhixia; Yu, Jiaojiao; Dai, Yu; Yang, Yue; Lu, Xiaoyu; Xu, Jiaqiu; Qin, Zhiying; Huang, Fang; Li, Ning

    2017-11-01

    A simple LC-MS/MS method facilitated by salting-out assisted liquid-liquid extraction (SALLE) was applied to simultaneously investigate the pharmacokinetics of trans-resveratrol (Res) and its major glucuronide and sulfate conjugates in rat plasma. Acetonitrile-methanol (80:20, v/v) and ammonium acetate (10 mol L -1 ) were used as extractant and salting-out reagent to locate the target analytes in the supernatant after the aqueous and organic phase stratification, then the analytes were determined via gradient elution by LC-MS/MS in negative mode in a single run. The analytical method was validated with good selectivity, acceptable accuracy (>85%) and low variation of precision (extraction efficiency of target glucuronide and sulfate conjugates (>80%). The method was successfully applied to determine Res and its four conjugated metabolites in rat after Res administration (intragastric, 50 mg kg -1 ; intravenous, 10 mg kg -1 ). The systemic exposures to Res conjugates were much higher than those to Res (AUC 0-t , i.v., 7.43 μm h; p.o., 8.31 μm h); Res-3-O-β-d-glucuronide was the major metabolite (AUC 0-t , i.v., 66.1 μm h; p.o., 333.4 μm h). The bioavailability of Res was estimated to be ~22.4%. The reproducible SALLE method simplified the sample preparation, drastically improved the accuracy of the concomitant assay and gave full consideration of extraction recovery to each target analyte in bio-samples. Copyright © 2017 John Wiley & Sons, Ltd.

  14. Amino acid analysis in physiological samples by GC-MS with propyl chloroformate derivatization and iTRAQ-LC-MS/MS.

    Science.gov (United States)

    Dettmer, Katja; Stevens, Axel P; Fagerer, Stephan R; Kaspar, Hannelore; Oefner, Peter J

    2012-01-01

    Two mass spectrometry-based methods for the quantitative analysis of free amino acids are described. The first method uses propyl chloroformate/propanol derivatization and gas chromatography-quadrupole mass spectrometry (GC-qMS) analysis in single-ion monitoring mode. Derivatization is carried out directly in aqueous samples, thereby allowing automation of the entire procedure, including addition of reagents, extraction, and injection into the GC-MS. The method delivers the quantification of 26 amino acids. The isobaric tagging for relative and absolute quantification (iTRAQ) method employs the labeling of amino acids with isobaric iTRAQ tags. The tags contain two different cleavable reporter ions, one for the sample and one for the standard, which are detected by fragmentation in a tandem mass spectrometer. Reversed-phase liquid chromatography of the labeled amino acids is performed prior to mass spectrometric analysis to separate isobaric amino acids. The commercial iTRAQ kit allows for the analysis of 42 physiological amino acids with a respective isotope-labeled standard for each of these 42 amino acids.

  15. The non-linear fitting method to analyze the measured M-S plots of bipolar passive films

    International Nuclear Information System (INIS)

    Jiang Ruijing; Chen Changfeng; Zheng Shuqi

    2010-01-01

    Mott-Schottky (M-S) analysis is an effective approach to investigate the electronic property of passive films of metals, and it is well suitable for the passive film with single space charge capacitance. But there is no proper method to analyze the C sc -2 vs. V m plots of passive films with several space charge capacitances in series connection, such as bipolar passive films. In this paper, the relationship between the space charge capacitance of the bipolar passive film and the applied potential was deduced and the features of corresponding plots were given out simultaneously. Accordingly, a non-linear fitting method was presented to analyze the C sc -2 vs. V m plots of bipolar passive films. Then the method was used to study the semiconductor characteristics of bipolar passive films formed on the surface of Nickel base alloy after being corroded in the environments with high temperatures and high partial pressures of H 2 S/CO 2 . The fitting results indicate that the non-linear fitting of M-S plots can well help to understand the anti-corrosion mechanism of bipolar passive films.

  16. Lung Cancer Serum Biomarker Discovery Using Label Free LC-MS/MS

    Science.gov (United States)

    Zeng, Xuemei; Hood, Brian L.; Zhao, Ting; Conrads, Thomas P.; Sun, Mai; Gopalakrishnan, Vanathi; Grover, Himanshu; Day, Roger S.; Weissfeld, Joel L.; Wilson, David O.; Siegfried, Jill M.; Bigbee, William L.

    2011-01-01

    Introduction Lung cancer remains the leading cause of cancer-related death with poor survival due to the late stage at which lung cancer is typically diagnosed. Given the clinical burden from lung cancer, and the relatively favorable survival associated with early stage lung cancer, biomarkers for early detection of lung cancer are of important potential clinical benefit. Methods We performed a global lung cancer serum biomarker discovery study using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in a set of pooled non-small cell lung cancer (NSCLC) case sera and matched controls. Immunoaffinity subtraction was used to deplete the top most abundant serum proteins; the remaining serum proteins were subjected to trypsin digestion and analyzed in triplicate by LC-MS/MS. The tandem mass spectrum data were searched against the human proteome database and the resultant spectral counting data were used to estimate the relative abundance of proteins across the case/control serum pools. The spectral counting derived abundances of some candidate biomarker proteins were confirmed with multiple reaction monitoring MS assays. Results A list of 49 differentially abundant candidate proteins was compiled by applying a negative binomial regression model to the spectral counting data (pbiomarkers with statistically significant differential abundance across the lung cancer case/control pools which, when validated, could improve lung cancer early detection. PMID:21304412

  17. The Ancient Wood of the Acqualadrone Rostrum: A Materials History Through GC-MS and Sulfur X-ray Absorption Spectroscopy

    Science.gov (United States)

    Frank, Patrick; Caruso, Francesco; Caponetti, Eugenio

    2012-01-01

    In 2008 the rostrum from an ancient warship was recovered from the Mediterranean near Acqualadrone, Sicily. To establish its provenance and condition, samples of black and brown rostrum wood were examined using sulfur K-edge x-ray absorption spectroscopy (XAS) and GC-MS. GC-MS of pyrolytic volatiles yielded only guaiacyl derivatives, indicating construction from pinewood. A derivatized extract of black wood yielded forms of abietic acid and sandaracopimaric acid consistent with pine pitch waterproofing. Numerical fits to the sulfur K-edge XAS spectra showed that about 65% of the endogenous sulfur consisted of thiols and disulfides. Elemental sulfur was about 2% and 7% in black and brown wood, respectively, while pyritic sulfur was about 12% and 6%. About 2% of the sulfur in both wood types was modeled as trimethylsulfonium, possibly reflecting biogenic dimethylsulfonio-propionate. High valent sulfur was exclusively represented by sulfate esters, consistent with bacterial sulfotransferase activity. Traces of chloride were detected, but no free sulfate ion. In summary, the rostrum was manufactured of pine wood and subsequently waterproofed with pine pitch. The subsequent 2300 years included battle, foundering, and marine burial followed by anoxia, bacterial colonization, sulfate reduction, and mobilization of transition metals, which produced pyrite and copious appended sulfur functionality. PMID:22545724

  18. Improving Student Understanding of Qualitative and Quantitative Analysis via GC/MS Using a Rapid SPME-Based Method for Determination of Trihalomethanes in Drinking Water

    Science.gov (United States)

    Huang, Shu Rong; Palmer, Peter T.

    2017-01-01

    This paper describes a method for determination of trihalomethanes (THMs) in drinking water via solid-phase microextraction (SPME) GC/MS as a means to develop and improve student understanding of the use of GC/MS for qualitative and quantitative analysis. In the classroom, students are introduced to SPME, GC/MS instrumentation, and the use of MS…

  19. Cerebral Ischemia versus MS in Young Adults Clinical Imaging Diagnosis Difficulties and Recovery Methods

    Directory of Open Access Journals (Sweden)

    Any DOCU-AXELERAD

    2012-12-01

    Full Text Available Ischemia in young adults is often the result of non-atherosclerotic vasculopathies, cardiac embolism or clotting disorders. One third of young adults ischemic stroke etiology remains undetermined. Materials and methods: We present the case of a patient aged 42, diagnosed with probable MS without cardiovascular or metabolic risk factors, presented to our clinic for decrease of force at right limbs and recent dysarthria. Results and discussion: The history revealed recurrent episodes of right hemi-body numbness and vertigo labeled as relapse in MS. Patient is non smoker, does not take oral contraceptives and has no history of cerebrovascular disease in the family. Extensive imaging and laboratory investigations confirms the ischemic clinical picture, carotid Doppler ultrasound showing significant stenosis of the bulbo-left carotid. The patient is guided to the cardiovascular surgery clinic for specialized treatment. Two weeks postoperatively we apply a kinetic-therapy program. Conclusion: Uncertain imaging and lack of vascular and metabolic risk factors do not preclude ischemia in young adults.

  20. Geometric estimation method for x-ray digital intraoral tomosynthesis

    Science.gov (United States)

    Li, Liang; Yang, Yao; Chen, Zhiqiang

    2016-06-01

    It is essential for accurate image reconstruction to obtain a set of parameters that describes the x-ray scanning geometry. A geometric estimation method is presented for x-ray digital intraoral tomosynthesis (DIT) in which the detector remains stationary while the x-ray source rotates. The main idea is to estimate the three-dimensional (3-D) coordinates of each shot position using at least two small opaque balls adhering to the detector surface as the positioning markers. From the radiographs containing these balls, the position of each x-ray focal spot can be calculated independently relative to the detector center no matter what kind of scanning trajectory is used. A 3-D phantom which roughly simulates DIT was designed to evaluate the performance of this method both quantitatively and qualitatively in the sense of mean square error and structural similarity. Results are also presented for real data acquired with a DIT experimental system. These results prove the validity of this geometric estimation method.