WorldWideScience

Sample records for method measures pressure

  1. Palpatory method of measuring diastolic blood pressure

    Directory of Open Access Journals (Sweden)

    Dinesh Sahu

    2010-01-01

    Conclusion: The palpatory method would be very useful where frequent blood pressure measurement are being done manually like in wards, in busy OPD, patient on treadmill and also whenever stethoscope is not available. The blood pressure can be measured in noisy environment too.

  2. A method enabling simultaneous pressure and temperature measurement using a single piezoresistive MEMS pressure sensor

    International Nuclear Information System (INIS)

    Frantlović, Miloš; Stanković, Srđan; Jokić, Ivana; Lazić, Žarko; Smiljanić, Milče; Obradov, Marko; Vukelić, Branko; Jakšić, Zoran

    2016-01-01

    In this paper we present a high-performance, simple and low-cost method for simultaneous measurement of pressure and temperature using a single piezoresistive MEMS pressure sensor. The proposed measurement method utilizes the parasitic temperature sensitivity of the sensing element for both pressure measurement correction and temperature measurement. A parametric mathematical model of the sensor was established and its parameters were calculated using the obtained characterization data. Based on the model, a real-time sensor correction for both pressure and temperature measurements was implemented in a target measurement system. The proposed method was verified experimentally on a group of typical industrial-grade piezoresistive sensors. The obtained results indicate that the method enables the pressure measurement performance to exceed that of typical digital industrial pressure transmitters, achieving at the same time the temperature measurement performance comparable to industrial-grade platinum resistance temperature sensors. The presented work is directly applicable in industrial instrumentation, where it can add temperature measurement capability to the existing pressure measurement instruments, requiring little or no additional hardware, and without adverse effects on pressure measurement performance. (paper)

  3. Thermopower measurement under high pressure using 'seesaw heating method'

    International Nuclear Information System (INIS)

    Hedo, M; Nakamura, D; Takaesu, Y; Yagasaki, K; Nakama, T; Fujiwara, T; Uchima, K

    2010-01-01

    We have developed a set-up with modified 'seesaw heating method' for the thermopower measurement under pressures P up to 3 GPa at the temperature range between 2 K and 300 K. By using this set-up, the thermopower and electrical resistivity of the single crystalline YbMn 2 Ge 2 under high pressure were measured with enough accuracy. S(T) curve shows the characteristic feature at the magnetic transition in all pressure range, while no evidence of the magnetic phase transition is observed in ρ(T) at P > 1.25 GPa. The measurement results indicate that the simultaneous measurement of the thermopower and electrical resistivity is a useful tool to study the pressure-induced phase transitions.

  4. New calibration method for I-scan sensors to enable the precise measurement of pressures delivered by 'pressure garments'.

    Science.gov (United States)

    Macintyre, Lisa

    2011-11-01

    Accurate measurement of the pressure delivered by medical compression products is highly desirable both in monitoring treatment and in developing new pressure inducing garments or products. There are several complications in measuring pressure at the garment/body interface and at present no ideal pressure measurement tool exists for this purpose. This paper summarises a thorough evaluation of the accuracy and reproducibility of measurements taken following both of Tekscan Inc.'s recommended calibration procedures for I-scan sensors; and presents an improved method for calibrating and using I-scan pressure sensors. The proposed calibration method enables accurate (±2.1 mmHg) measurement of pressures delivered by pressure garments to body parts with a circumference ≥30 cm. This method is too cumbersome for routine clinical use but is very useful, accurate and reproducible for product development or clinical evaluation purposes. Copyright © 2011 Elsevier Ltd and ISBI. All rights reserved.

  5. Non-destructive residual pressure self-measurement method for the sensing chip of optical Fabry-Perot pressure sensor.

    Science.gov (United States)

    Wang, Xue; Wang, Shuang; Jiang, Junfeng; Liu, Kun; Zhang, Xuezhi; Xiao, Mengnan; Xiao, Hai; Liu, Tiegen

    2017-12-11

    We introduce a simple residual pressure self-measurement method for the Fabry-Perot (F-P) cavity of optical MEMS pressure sensor. No extra installation is required and the structure of the sensor is unchanged. In the method, the relationship between residual pressure and external pressure under the same diaphragm deflection condition at different temperatures is analyzed by using the deflection formula of the circular plate with clamped edges and the ideal gas law. Based on this, the residual pressure under the flat condition can be obtained by pressure scanning process and calculation process. We carried out the experiment to compare the residual pressures of two batches MEMS sensors fabricated by two kinds of bonding process. The measurement result indicates that our approach is reliable enough for the measurement.

  6. Investigation on field method using strain measurement on pipe surface to measure pressure pulsation in piping systems

    International Nuclear Information System (INIS)

    Maekawa, Akira; Tsuji, Takashi; Takahashi, Tsuneo; Kato, Minoru

    2013-01-01

    Accurate evaluation of the occurrence location and amplitude of pressure pulsations in piping systems can lead to efficient plant maintenance by preventing fatigue failure of piping and components because the pulsations can be one of the main causes of vibration fatigue and acoustic noise in piping. A non-destructive field method to measure pressure pulsations easily and directly was proposed to replace conventional methods such as prediction using numerical simulations and estimation using locally installed pressure gauges. The proposed method was validated experimentally by measuring pulsating flow in a mock-up piping system. As a result, it was demonstrated that the method to combine strain measurement on the outer surface of pipe with the formula for thick-walled cylinders could measure amplitudes and behavior of the pressure pulsations with a practical accuracy. Factors affecting the measurement accuracy of the proposed method were also discussed. Furthermore, the applicability of the formula for thin-walled cylinders was examined for variously shaped pipes. (author)

  7. Evaluation of the monitor cursor-line method for measuring pulmonary artery and central venous pressures.

    Science.gov (United States)

    Pasion, Editha; Good, Levell; Tizon, Jisebelle; Krieger, Staci; O'Kier, Catherine; Taylor, Nicole; Johnson, Jennifer; Horton, Carrie M; Peterson, Mary

    2010-11-01

    To determine if the monitor cursor-line feature on bedside monitors is accurate for measuring central venous and pulmonary artery pressures in cardiac surgery patients. Central venous and pulmonary artery pressures were measured via 3 methods (end-expiratory graphic recording, monitor cursor-line display, and monitor digital display) in a convenience sample of postoperative cardiac surgery patients. Pressures were measured twice during both mechanical ventilation and spontaneous breathing. Analysis of variance was used to determine differences between measurement methods and the percentage of monitor pressures that differed by 4 mm Hg or more from the measurement obtained from the graphic recording. Significance level was set at P less than .05. Twenty-five patients were studied during mechanical ventilation (50 measurements) and 21 patients during spontaneous breathing (42 measurements). Measurements obtained via the 3 methods did not differ significantly for either type of pressure (P > .05). Graphically recorded pressures and measurements obtained via the monitor cursor-line or digital display methods differed by 4 mm Hg or more in 4% and 6% of measurements, respectively, during mechanical ventilation and 4% and 11%, respectively, during spontaneous breathing. The monitor cursor-line method for measuring central venous and pulmonary artery pressures may be a reasonable alternative to the end-expiratory graphic recording method in hemodynamically stable, postoperative cardiac surgery patients. Use of the digital display on the bedside monitor may result in larger discrepancies from the graphically recorded pressures than when the cursor-line method is used, particularly in spontaneously breathing patients.

  8. A method to measure paddle and detector pressures and footprints in mammography

    Energy Technology Data Exchange (ETDEWEB)

    Hogg, Peter; Szczepura, Katy [University of Salford, Salford, Greater Manchester M6 6PU (United Kingdom); Darlington, Alison [Pennine Acute Hospital NHS Trust, Manchester M8 5RB (United Kingdom); Maxwell, Anthony [Royal Bolton Hospital NHS Foundation Trust, Bolton BL4 0JR (United Kingdom)

    2013-04-15

    Purpose: Compression is necessary in mammography to improve image quality and reduce radiation burden. Maximizing the amount of breast in contact with the image receptor (IR) is important. To achieve this, for the craniocaudal projection, there is no consensus within the literature regarding how the IR should be positioned relative to the inframammary fold (IMF). No information exists within the literature to describe how pressure balancing between IR and paddle, and IR breast footprint, might be optimized. This paper describes a novel method for measuring the respective pressures applied to the breast from the IR and the paddle and a method to simultaneously measure the breast footprints on the IR and the paddle. Methods: Using a deformable breast phantom and electronic pressure-sensitive mat, area and pressure readings were gathered from two mammography machines and four paddles at 60, 80, and 100 N with the IR positioned at -2, -1, 0, +1, and +2 cm relative to the IMF (60 combinations in total). Results: Paddle and IR footprints were calculated along with a uniformity index (UI). For all four paddle/machine/pressure combinations the greatest IR footprint was achieved at IMF +2 cm. The UI indicates that the best pressure/footprint balance is achieved at IMF +1 cm. Conclusions: The authors' method appears to be suited to measuring breast footprints and pressures on IR and paddle and a human female study is planned.

  9. A method to measure paddle and detector pressures and footprints in mammography

    International Nuclear Information System (INIS)

    Hogg, Peter; Szczepura, Katy; Darlington, Alison; Maxwell, Anthony

    2013-01-01

    Purpose: Compression is necessary in mammography to improve image quality and reduce radiation burden. Maximizing the amount of breast in contact with the image receptor (IR) is important. To achieve this, for the craniocaudal projection, there is no consensus within the literature regarding how the IR should be positioned relative to the inframammary fold (IMF). No information exists within the literature to describe how pressure balancing between IR and paddle, and IR breast footprint, might be optimized. This paper describes a novel method for measuring the respective pressures applied to the breast from the IR and the paddle and a method to simultaneously measure the breast footprints on the IR and the paddle. Methods: Using a deformable breast phantom and electronic pressure-sensitive mat, area and pressure readings were gathered from two mammography machines and four paddles at 60, 80, and 100 N with the IR positioned at −2, −1, 0, +1, and +2 cm relative to the IMF (60 combinations in total). Results: Paddle and IR footprints were calculated along with a uniformity index (UI). For all four paddle/machine/pressure combinations the greatest IR footprint was achieved at IMF +2 cm. The UI indicates that the best pressure/footprint balance is achieved at IMF +1 cm. Conclusions: The authors’ method appears to be suited to measuring breast footprints and pressures on IR and paddle and a human female study is planned.

  10. Arterial pressure measurement: Is the envelope curve of the oscillometric method influenced by arterial stiffness?

    International Nuclear Information System (INIS)

    Gelido, G; Angiletta, S; Pujalte, A; Quiroga, P; Cornes, P; Craiem, D

    2007-01-01

    Measurement of peripheral arterial pressure using the oscillometric method is commonly used by professionals as well as by patients in their homes. This non invasive automatic method is fast, efficient and the required equipment is affordable with a low cost. The measurement method consists of obtaining parameters from a calibrated decreasing curve that is modulated by heart beats witch appear when arterial pressure reaches the cuff pressure. Diastolic, mean and systolic pressures are obtained calculating particular instants from the heart beats envelope curve. In this article we analyze the envelope of this amplified curve to find out if its morphology is related to arterial stiffness in patients. We found, in 33 volunteers, that the envelope waveform width correlates to systolic pressure (r=0.4, p<0.05), to pulse pressure (r=0.6, p<0.05) and to pulse pressure normalized to systolic pressure (r=0.6, p<0.05). We believe that the morphology of the heart beats envelope curve obtained with the oscillometric method for peripheral pressure measurement depends on arterial stiffness and can be used to enhance pressure measurements

  11. Measuring fluid pressure

    International Nuclear Information System (INIS)

    Lee, A.S.

    1978-01-01

    A method and apparatus are described for measuring the pressure of a fluid having characteristics that make it unsuitable for connection directly to a pressure gauge. The method is particularly suitable for the periodic measurement of the pressure of a supply of liquid Na to Na-lubricated bearings of pumps for pumping Na from a reservoir to the bearing via a filter, the reservoir being contained in a closed vessel containing an inert blanket gas, such as Ar, above the Na. (UK)

  12. An ultrasound-based liquid pressure measurement method in small diameter pipelines considering the installation and temperature.

    Science.gov (United States)

    Li, Xue; Song, Zhengxiang

    2015-04-09

    Liquid pressure is a key parameter for detecting and judging faults in hydraulic mechanisms, but traditional measurement methods have many deficiencies. An effective non-intrusive method using an ultrasound-based technique to measure liquid pressure in small diameter (less than 15 mm) pipelines is presented in this paper. The proposed method is based on the principle that the transmission speed of an ultrasonic wave in a Kneser liquid correlates with liquid pressure. Liquid pressure was calculated using the variation of ultrasonic propagation time in a liquid under different pressures: 0 Pa and X Pa. In this research the time difference was obtained by an electrical processing approach and was accurately measured to the nanosecond level through a high-resolution time measurement module. Because installation differences and liquid temperatures could influence the measurement accuracy, a special type of circuit called automatic gain control (AGC) circuit and a new back propagation network (BPN) model accounting for liquid temperature were employed to improve the measurement results. The corresponding pressure values were finally obtained by utilizing the relationship between time difference, transient temperature and liquid pressure. An experimental pressure measurement platform was built and the experimental results confirm that the proposed method has good measurement accuracy.

  13. A new method for measuring the response time of the high pressure ionization chamber

    International Nuclear Information System (INIS)

    Wang, Zhentao; Shen, Yixiong; An, Jigang

    2012-01-01

    Time response is an important performance characteristic for gas-pressurized ionization chambers. To study the time response, it is especially crucial to measure the ion drift time in high pressure ionization chambers. In this paper, a new approach is proposed to study the ion drift time in high pressure ionization chambers. It is carried out with a short-pulsed X-ray source and a high-speed digitizer. The ion drift time in the chamber is then determined from the digitized data. By measuring the ion drift time of a 15 atm xenon testing chamber, the method has been proven to be effective in the time response studies of ionization chambers. - Highlights: ► A method for measuring response time of high pressure ionization chamber is proposed. ► A pulsed X-ray producer and a digital oscilloscope are used in the method. ► The response time of a 15 atm Xenon testing ionization chamber has been measured. ► The method has been proved to be simple, feasible and effective.

  14. Study of a pressure measurement method using laser ionization for extremely-high vacuum

    International Nuclear Information System (INIS)

    Kokubun, Kiyohide

    1991-01-01

    A method of measuring pressures in the range of extremely-high vacuum (XHV) using the laser ionization has been studied. For this purpose, nonresonant multiphoton ionization of various kinds of gases has been studied, and highly-sensitive ion-detection systems and an extremely-high vacuum equipment were fabricated. These results are presented in detail. Two ion-detection systems were fabricated and tested: the one is based on the pulse-counting method, and the other utilizes the image-processing technique. The former is superior in detecting a few ions or less. The latter was processing technique. The former is superior in detecting a few ions or less. The latter was verified to able to count accurately the number of ions in the range of a few to several hundreds. To obtain the information on residual gases and test our pressure measurement system, an extremely-high vacuum system was fabricated in our own fashion, attained a pressure lower than 1 x 10 -10 Pa, measured with an extractor gauge. The outgassing rate of this vacuum vessel was measured to be 7.8 x 10 -11 Pa·m 3 /s·m 2 . The surface structures and the surface compositions of the raw material, the machined material, and the machined-and-outgased material were studied by SEM and AES. Besides, the pumping characteristics and the residual gases of the XHV system were investigated in detail at each pumping stage. On the course of these studies, the method of pressure measurement using the laser-ionization has been verified to be very effective for measuring pressures in XHV. (J.P.N.)

  15. Detection of small-amplitude periodic surface pressure fluctuation by pressure-sensitive paint measurements using frequency-domain methods

    Science.gov (United States)

    Noda, Takahiro; Nakakita, Kazuyki; Wakahara, Masaki; Kameda, Masaharu

    2018-06-01

    Image measurement using pressure-sensitive paint (PSP) is an effective tool for analyzing the unsteady pressure field on the surface of a body in a low-speed air flow, which is associated with wind noise. In this study, the surface pressure fluctuation due to the tonal trailing edge (TE) noise for a two-dimensional NACA 0012 airfoil was quantitatively detected using a porous anodized aluminum PSP (AA-PSP). The emission from the PSP upon illumination by a blue laser diode was captured using a 12-bit high-speed complementary metal-oxide-semiconductor (CMOS) camera. The intensities of the captured images were converted to pressures using a standard intensity-based method. Three image-processing methods based on the fast Fourier transform (FFT) were tested to determine their efficiency in improving the signal-to-noise ratio (SNR) of the unsteady PSP data. In addition to two fundamental FFT techniques (the full data and ensemble averaging FFTs), a technique using the coherent output power (COP), which involves the cross correlation between the PSP data and the signal measured using a pointwise sound-level meter, was tested. Preliminary tests indicated that random photon shot noise dominates the intensity fluctuations in the captured PSP emissions above 200 Hz. Pressure fluctuations associated with the TE noise, whose dominant frequency is approximately 940 Hz, were successfully measured by analyzing 40,960 sequential PSP images recorded at 10 kfps. Quantitative validation using the power spectrum indicates that the COP technique is the most effective method of identification of the pressure fluctuation directly related to TE noise. It is possible to distinguish power differences with a resolution of 10 Pa^2 (4 Pa in amplitude) when the COP was employed without use of another wind-off data. This resolution cannot be achieved by the ensemble averaging FFT because of an insufficient elimination of the background noise.

  16. Excessive leakage measurement using pressure decay method in containment building local leakage rate test at nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Won Kyu; Kim, Chang Soo; Kim, Wang Bae [KHNP, Central Research Institute, Daejeon (Korea, Republic of)

    2016-06-15

    There are two methods for conducting the containment local leakage rate test (LLRT) in nuclear power plants: the make-up flow rate method and the pressure decay method. The make-up flow rate method is applied first in most power plants. In this method, the leakage rate is measured by checking the flow rate of the make-up flow. However, when it is difficult to maintain the test pressure because of excessive leakage, the pressure decay method can be used as a complementary method, as the leakage rates at pressures lower than normal can be measured using this method. We studied the method of measuring over leakage using the pressure decay method for conducting the LLRT for the containment building at a nuclear power plant. We performed experiments under conditions similar to those during an LLRT conducted on-site. We measured the characteristics of the leakage rate under varies pressure decay conditions, and calculated the compensation ratio based on these data.

  17. An Investigation of Pulse Transit Time as a Non-Invasive Blood Pressure Measurement Method

    International Nuclear Information System (INIS)

    McCarthy, B M; O'Flynn, B; Mathewson, A

    2011-01-01

    The objective of this paper is to examine the Pulse Transit Method (PTT) as a non-invasive means to track Blood Pressure over a short period of time. PTT was measured as the time it takes for an ECG R-wave to propagate to the finger, where it is detected by a photoplethysmograph sensor. The PTT method is ideal for continuous 24-hour Blood Pressure Measurement (BPM) since it is both cuff-less and non-invasive and therefore comfortable and unobtrusive for the patient. Other techniques, such as the oscillometric method, have shown to be accurate and reliable but require a cuff for operation, making them unsuitable for long term monitoring. Although a relatively new technique, the PTT method has shown to be able to accurately track blood pressure changes over short periods of time, after which re-calibration is necessary. The purpose of this study is to determine the accuracy of the method.

  18. Measurement of micro Bubbles generated by a pressurized dissolution method

    Energy Technology Data Exchange (ETDEWEB)

    Hosokawa, S; Tanaka, K; Tomiyama, A [Kobe University, 1-1 Rokkodai, Nada, Kobe 657-8501 (Japan); Maeda, Y; Yamaguchi, S; Ito, Y, E-mail: hosokawa@mech.kobe-u.ac.j [Panasonic Electric Works Co., Ltd., 1048 Kadoma, Osaka 571-8686 (Japan)

    2009-02-01

    Diameters of micro-bubbles are apt to range from about one mm to several-hundred mm, and therefore, it is difficult to measure a correct diameter distribution using a single measurement method. In this study, diameters of bubbles generated by a pressurized dissolution method are measured by using phase Doppler anemometry (PDA) and an image processing method, which is based on the Sobel filter and Hough transform. The diameter distribution and the Sauter mean diameter of micro bubbles are evaluated based on the diameters measured by both methods. Experiments are conducted for several mass flow rates of dissolved gas and of air bubbles entrained in the upstream of the decompression nozzle to examine effects of the entrained bubbles on bubble diameter. As a result, the following conclusions are obtained: (1) Diameter distribution of micro bubbles can be accurately measured for a wide range of diameter by using PDA and the image processing method. (2) The mean diameter of micro-bubbles generated by gasification of dissolved gas is smaller than that generated by breakup of air bubbles entrained in the upstream of the decompression nozzle. (3) The mean bubble diameter increases with the entrainment of air bubbles in the upstream of the decompression nozzle at a constant mass flow rate of dissolved gas.

  19. Measurement of micro Bubbles generated by a pressurized dissolution method

    International Nuclear Information System (INIS)

    Hosokawa, S; Tanaka, K; Tomiyama, A; Maeda, Y; Yamaguchi, S; Ito, Y

    2009-01-01

    Diameters of micro-bubbles are apt to range from about one mm to several-hundred mm, and therefore, it is difficult to measure a correct diameter distribution using a single measurement method. In this study, diameters of bubbles generated by a pressurized dissolution method are measured by using phase Doppler anemometry (PDA) and an image processing method, which is based on the Sobel filter and Hough transform. The diameter distribution and the Sauter mean diameter of micro bubbles are evaluated based on the diameters measured by both methods. Experiments are conducted for several mass flow rates of dissolved gas and of air bubbles entrained in the upstream of the decompression nozzle to examine effects of the entrained bubbles on bubble diameter. As a result, the following conclusions are obtained: (1) Diameter distribution of micro bubbles can be accurately measured for a wide range of diameter by using PDA and the image processing method. (2) The mean diameter of micro-bubbles generated by gasification of dissolved gas is smaller than that generated by breakup of air bubbles entrained in the upstream of the decompression nozzle. (3) The mean bubble diameter increases with the entrainment of air bubbles in the upstream of the decompression nozzle at a constant mass flow rate of dissolved gas.

  20. Development of the CARS method for measurement of pressure and temperature gradients in centrifuges

    International Nuclear Information System (INIS)

    Zeltmann, A.H.; Valentini, J.J.

    1983-12-01

    These experiments evaluated the feasibility of applying the CARS technique to the measurement of UF 6 concentrations and pressure gradients in a gas centrifuge. The resultant CARS signals were properly related to system parameters as suggested by theory. The results have been used to guide design of an apparatus for making CARS measurements in a UF 6 gas centrifuge. Ease of measurement is expected for pressures as low as 0.1 torr. Temperature gradients can be measured by this technique with changes in the data acquisition method. 16 references, 8 figures, 2 tables

  1. Blood Pressure Measurement: Clinic, Home, Ambulatory, and Beyond

    Science.gov (United States)

    Drawz, Paul E.; Abdalla, Mohamed; Rahman, Mahboob

    2014-01-01

    Blood pressure has traditionally been measured in the clinic setting using the auscultory method and a mercury sphygmomanometer. Technological advances have led to improvements in measuring clinic blood pressure and allowed for measuring blood pressures outside the clinic. This review outlines various methods for evaluating blood pressure and the clinical utility of each type of measurement. Home blood pressures and 24 hour ambulatory blood pressures have improved our ability to evaluate risk for target organ damage and hypertension related morbidity and mortality. Measuring home blood pressures may lead to more active participation in health care by patients and has the potential to improve blood pressure control. Ambulatory blood pressure monitoring enables the measuring nighttime blood pressures and diurnal changes, which may be the most accurate predictors of risk associated with elevated blood pressure. Additionally, reducing nighttime blood pressure is feasible and may be an important component of effective antihypertensive therapy. Finally, estimating central aortic pressures and pulse wave velocity are two of the newer methods for assessing blood pressure and hypertension related target organ damage. PMID:22521624

  2. Leak Rate Quantification Method for Gas Pressure Seals with Controlled Pressure Differential

    Science.gov (United States)

    Daniels, Christopher C.; Braun, Minel J.; Oravec, Heather A.; Mather, Janice L.; Taylor, Shawn C.

    2015-01-01

    An enhancement to the pressure decay leak rate method with mass point analysis solved deficiencies in the standard method. By adding a control system, a constant gas pressure differential across the test article was maintained. As a result, the desired pressure condition was met at the onset of the test, and the mass leak rate and measurement uncertainty were computed in real-time. The data acquisition and control system were programmed to automatically stop when specified criteria were met. Typically, the test was stopped when a specified level of measurement uncertainty was attained. Using silicone O-ring test articles, the new method was compared with the standard method that permitted the downstream pressure to be non-constant atmospheric pressure. The two methods recorded comparable leak rates, but the new method recorded leak rates with significantly lower measurement uncertainty, statistical variance, and test duration. Utilizing this new method in leak rate quantification, projects will reduce cost and schedule, improve test results, and ease interpretation between data sets.

  3. A study on new method of noninvasive esophageal venous pressure measurement based on the airflow and laser detection technology.

    Science.gov (United States)

    Hu, Chenghuan; Huang, Feizhou; Zhang, Rui; Zhu, Shaihong; Nie, Wanpin; Liu, Xunyang; Liu, Yinglong; Li, Peng

    2015-01-01

    Using optics combined with automatic control and computer real-time image detection technology, a novel noninvasive method of noncontact pressure manometry was developed based on the airflow and laser detection technology in this study. The new esophageal venous pressure measurement system was tested in-vitro experiments. A stable and adjustable pulse stream was produced from a self-developed pump and a laser emitting apparatus could generate optical signals which can be captured by image acquisition and analysis system program. A synchronization system simultaneous measured the changes of air pressure and the deformation of the vein wall to capture the vascular deformation while simultaneously record the current pressure value. The results of this study indicated that the pressure values tested by the new method have good correlation with the actual pressure value in animal experiments. The new method of noninvasive pressure measurement based on the airflow and laser detection technology is accurate, feasible, repeatable and has a good application prospects.

  4. Measuring Viscosities of Gases at Atmospheric Pressure

    Science.gov (United States)

    Singh, Jag J.; Mall, Gerald H.; Hoshang, Chegini

    1987-01-01

    Variant of general capillary method for measuring viscosities of unknown gases based on use of thermal mass-flowmeter section for direct measurement of pressure drops. In technique, flowmeter serves dual role, providing data for determining volume flow rates and serving as well-characterized capillary-tube section for measurement of differential pressures across it. New method simple, sensitive, and adaptable for absolute or relative viscosity measurements of low-pressure gases. Suited for very complex hydrocarbon mixtures where limitations of classical theory and compositional errors make theoretical calculations less reliable.

  5. Home blood pressure measurement in elderly patients with cognitive impairment: comparison of agreement between relative-measured blood pressure and automated blood pressure measurement.

    Science.gov (United States)

    Plichart, Matthieu; Seux, Marie-Laure; Caillard, Laure; Chaussade, Edouard; Vidal, Jean-Sébastien; Boully, Clémence; Hanon, Olivier

    2013-08-01

    Home blood pressure measurement (HBPM) is recommended by guidelines for hypertension management. However, this method might be difficult to use in elderly individuals with cognitive disorders. Our aim was to assess the agreement and the feasibility of HBPM by a relative as compared with 24-h ambulatory blood pressure monitoring (ABPM) in elderly patients with dementia. Sixty outpatients with dementia aged 75 years and older with office hypertension (≥140/90 mmHg) were subjected successively to HBPM by a trained relative and 24-h ABPM. The order of the two methods was randomized. Current guidelines' thresholds for the diagnosis of hypertension were used. The mean (SD) age of the patients was 80.8 (6.1) years (55% women) and the mean (SD) mini-mental state examination score was 20.1 (6.9). The feasibility of relative-HBPM was very high, with a 97% success rate (defined by ≥12/18 measurements reported). The blood pressure measurements were highly correlated between the two methods (r=0.75 and 0.64 for systolic blood pressure and diastolic blood pressure, respectively; Pmethods for the diagnosis of sustained hypertension and white-coat hypertension was excellent (overall agreement, 92%; κ coefficient, 0.81; 95% CI, 0.61-0.93). Similar results were found for daytime-ABPM. In cognitively impaired elderly patients, HBPM by a relative using an automated device was a good alternative to 24-h ABPM.

  6. New method to measure the angular antispring effect in a Fabry–Perot cavity with remote excitation using radiation pressure

    Energy Technology Data Exchange (ETDEWEB)

    Nagano, Koji, E-mail: knagano@icrr.u-tokyo.ac.jp [Institute for Cosmic Ray Research, The University of Tokyo, 5-1-5 Kashiwa-no-Ha, Kashiwa, Chiba 277-8582 (Japan); Enomoto, Yutaro; Nakano, Masayuki [Institute for Cosmic Ray Research, The University of Tokyo, 5-1-5 Kashiwa-no-Ha, Kashiwa, Chiba 277-8582 (Japan); Furusawa, Akira [Department of Applied Physics, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Kawamura, Seiji [Institute for Cosmic Ray Research, The University of Tokyo, 5-1-5 Kashiwa-no-Ha, Kashiwa, Chiba 277-8582 (Japan)

    2016-03-06

    In experiments with Fabry–Perot cavities consisting of suspended mirrors, an angular antispring effect on the mirror of the cavity is caused by radiation pressure from resonant light in the cavity. A new method was invented to measure the effect precisely with remote excitation on the mirror using the radiation pressure. This method was found to be available for the suspended 23 mg mirror and improved the measurement accuracy by a factor of two, compared with the previous method. This result leads to stable control systems to eliminate the angular instability of the mirror caused by the effect. - Highlights: • A method to measure an angular antispring effect on a suspended mirror was proposed. • Remote excitation on the mirror with radiation pressure of resonant light is used. • This method provides better measurement accuracy compared with the previous method.

  7. Measurement of the surface tension by the method of maximum gas bubble pressure

    International Nuclear Information System (INIS)

    Dugne, Jean

    1971-01-01

    A gas bubble method for measuring surface tension was studied. Theoretical investigations demonstrated that the maximum pressure can be represented by the envelope of a certain family of curves and that the physical nature of the capillary tube imposes an upper limit to its useful radius. With a given tube and a specified liquid, the dynamic evolution of the gas bubble depends only upon the variation of the mass of gas contained with time; this fact may restrict the choice of tubes. The use of one single tube requires important corrections. Computer treatment of the problem led to some accurate equations for calculating γ. Schroedinger equations and Sudgen's table are examined. The choice of tubes, the necessary corrections, density measurement, and the accuracy attainable are discussed. Experiments conducted with water and mercury using the sessile drop method and continuous recording of the pressure verified the theoretical ideas. (author) [fr

  8. Thermogravimetric measurements of liquid vapor pressure

    International Nuclear Information System (INIS)

    Rong Yunhong; Gregson, Christopher M.; Parker, Alan

    2012-01-01

    Highlights: ► Rapid determination of vapor pressure by TGA. ► Demonstration of limitations of currently available approaches in literature. ► New model for vapor pressure assessment of small size samples in TGA. ► New model accounts for vapor diffusion and sample geometry and measures vapor pressure normally within 10%. - Abstract: A method was developed using thermo-gravimetric analysis (TGA) to determine the vapor pressure of volatile liquids. This is achieved by measuring the rate of evaporation (mass loss) of a pure liquid contained within a cylindrical pan. The influence of factors like sample geometry and vapor diffusion on evaporation rate are discussed. The measurement can be performed across a wide range of temperature yielding reasonable results up to 10 kPa. This approach may be useful as a rapid and automatable method for measuring the volatility of flavor and fragrance raw materials.

  9. On-line pressure measurement using scanning systems

    International Nuclear Information System (INIS)

    Morss, A.G.; Watson, A.P.

    1978-08-01

    Data collection methods can be improved significantly by using pressure scanning systems in conjunction with transducers for the measurement of pressure distribution in fluid flow rigs. However, the response of pressure transducers to the slight random pressure fluctuations that occur in practice can cause some measurement problems, especially for accurate work. The nature of these pressure fluctuations is examined and suitable analysis techniques are recommended. Results obtained using these techniques are presented. It is concluded that by using the correct techniques pressure transducer systems can be used to measure pressure distributions accurately and are sufficiently sensitive to measure very small systematic effects with great precision. (author)

  10. Velocity-pressure correlation measurements in complex free shear flows

    International Nuclear Information System (INIS)

    Naka, Yoshitsugu; Obi, Shinnosuke

    2009-01-01

    Simultaneous measurements of fluctuating velocity and pressure were performed in various turbulent free shear flows including a turbulent mixing layer and the wing-tip vortex trailing from a NACA0012 half-wing. Two different methods for fluctuating static pressure measurement were considered: a direct method using a miniature Pitot tube and an indirect method where static pressure was calculated from total pressure. The pressure obtained by either of these methods was correlated with the velocity measured by an X-type hot-wire probe. The results from these two techniques agreed with each other in the turbulent mixing layer. In the wing-tip vortex case, however, some discrepancies were found, although overall characteristics of the pressure-related statistics were adequately captured by both methods.

  11. Blood pressure and anthropometric measurements in healthy ...

    African Journals Online (AJOL)

    Methods. We measured the blood pressures of 650 healthy, randomly ... In addition, blood pressure measurement should be a part of the routine clinical examination of children. ... familial risk factors.2 ... common cause of elevated blood pressure in children.4 They ... sphygmomanometer (Accoson, hospital model BS 274,.

  12. Radioisotope method for assessing skin blood pressure

    International Nuclear Information System (INIS)

    Tarkowska, A.; Misiunia, P.; Woytowicz, A.; Olewinski, T.

    1979-01-01

    A method of measuring the skin blood pressure (SBP) evolved by Holstein and Lassen is described. The method is based on determination of the force of pressure causing blockade of Na 131 I clearance from the site of its intradermal injection. Using this method it was found that in the lower extremities in healthy subjects the SBP approached the diastolic pressure measured by the conventional method in the brachial artery. On the other hand in patients with obliterative arteriosclerosis and in Buerger's disease the SBP was considerably lower than the diastolic arterial pressure. The authors think that the method gives a good insight into the state of blood supply to the extremities in healthy subjects and in peripheral vascular failure. (author)

  13. Method for sensing and measuring a concentration or partial pressure of a reactant used in a redox reaction

    Science.gov (United States)

    Findl, E.

    1984-12-21

    A method for sensing or measuring the partial pressure or concentration of an electroactive species used in conjunction with an electrolyte, the method being characterized by providing a constant current between an anode and a cathode of an electrolyte-containing cell, while measuring changes in voltage that occur between either the anode and cathode or between a reference electrode and one of the main electrodes of the cell, thereby to determine the concentration or partial pressure of the electro-active species as a function of said measured voltage changes. The method of the invention can be practiced using either a cell having only an anode and a cathode, or using a cell having an anode and a cathode in combination with a reference electrode. Accurate measurements of small concentrations or partial pressures of electro-active species are obtainable with the method of the invention, by using constant currents of only a few microamperes between the anode and cathode of the cell, while the concentration-determining voltage is measured.

  14. Hydrogen equilibrium pressure measurements in the Li-N-H system by static manometric method

    International Nuclear Information System (INIS)

    Ananda, N.S.; Jat, R.A.; Sawant, S.G.; Parida, S.C.; Singh, Z.; Venugopal, V.

    2010-01-01

    Light weight hydrogen storage materials are very promising in terms of their high gravimetric hydrogen storage capacity and low cost. One such reported system is the Li-N-H system with a theoretical hydrogen capacity of 11.5 wt% according to the following equilibrium reactions; (1) Li 3 N+H 2 → Li 2 NH + LiH and (2) Li 2 NH+H 2 → LiNH 2 + LiH. The enthalpy of reaction (1) is -165 kJ/mole of H 2 whereas that of reaction (2) is -45 kJ/mole of H 2 . Hence, the second reaction is of utmost importance for low temperature release of hydrogen with a capacity of 6.5 wt%. The equilibrium hydrogen pressures of the above two reactions have been reported by pressure-composition isotherm studies at a pressure range of 3-15 atm., in which the mid-point of the sloping plateau of P-C isotherm is considered as the equilibrium pressure. This method may not yield the true equilibrium pressure. Hence, in this study, we have carried out measurements of equilibrium pressure using a static manometric method where we have considered reaction (2) only

  15. Gas permeation measurement under defined humidity via constant volume/variable pressure method

    KAUST Repository

    Jan Roman, Pauls

    2012-02-01

    Many industrial gas separations in which membrane processes are feasible entail high water vapour contents, as in CO 2-separation from flue gas in carbon capture and storage (CCS), or in biogas/natural gas processing. Studying the effect of water vapour on gas permeability through polymeric membranes is essential for materials design and optimization of these membrane applications. In particular, for amine-based CO 2 selective facilitated transport membranes, water vapour is necessary for carrier-complex formation (Matsuyama et al., 1996; Deng and Hägg, 2010; Liu et al., 2008; Shishatskiy et al., 2010) [1-4]. But also conventional polymeric membrane materials can vary their permeation behaviour due to water-induced swelling (Potreck, 2009) [5]. Here we describe a simple approach to gas permeability measurement in the presence of water vapour, in the form of a modified constant volume/variable pressure method (pressure increase method). © 2011 Elsevier B.V.

  16. Corneal Vibrations during Intraocular Pressure Measurement with an Air-Puff Method

    Directory of Open Access Journals (Sweden)

    Robert Koprowski

    2018-01-01

    Full Text Available Introduction. The paper presents a commentary on the method of analysis of corneal vibrations occurring during eye pressure measurements with air-puff tonometers, for example, Corvis. The presented definition and measurement method allow for the analysis of image sequences of eye responses—cornea deformation. In particular, the outer corneal contour and sclera fragments are analysed, and 3D reconstruction is performed. Methods. On this basis, well-known parameters such as eyeball reaction or corneal response are determined. The next steps of analysis allow for automatic and reproducible separation of four different corneal vibrations. These vibrations are associated with (1 the location of the maximum of cornea deformation; (2 the cutoff area measured in relation to the cornea in a steady state; (3 the maximum of peaks occurring between applanations; and (4 the other characteristic points of the corneal contour. Results. The results obtained enable (1 automatic determination of the amplitude of vibrations; (2 determination of the frequency of vibrations; and (3 determination of the correlation between the selected types of vibrations. Conclusions. These are diagnostic features that can be directly applied clinically for new and archived data.

  17. [Contemporary possibilities of intraocular pressure measurement].

    Science.gov (United States)

    Hornová, J; Baxant, A

    2013-10-01

    Authors introduced current possibilities of measuring intraocular pressure (IOP). A list of available methods of monitoring IOP is published; contact measurement method IOP directly on the cornea, but also over upper lid, methodology of minimal contact and non-contact measurement. Following contact methods are described; former measurements of IOP by impression Schiotz tonometer and the current methodology applanation. So far as the gold standard measurement Goldmann applanation tonometer (GAT) is considered, another methodology with applanation measurements are compared: Pascal dynamic contoured tonometer (DCT ), BioResonator - resonant applanation tonometer (ART ), digital applanation tonometer Tonopen and last hit: continuous measurement of IOP by Sensimed Triggerfish. Orientation and rapid assessment is palpation pressure control over the lid and measuring by tonometer Diaton. Rebound tonometer (RBT) iCare belongs to measurements with minimal contact, no need anesthetic drops and fluorescein, therefore a self - home version of IOP measurements (Icare ONE) is developed. Non-contact measurement of IOP by different pneumotonometers is popular for screening assessment of IOP. Reichert Ocular Response Analyzer (ORA) is a non-contact applanation IOP measurement and reveals additional properties of the cornea. In the discussion of a range methodology is evaluated, the experience of other authors and their own experience is compared. For monitoring of patients is necessary to select the most suitable methodology, measure repeatedly and accurately to allow long-term monitoring of intraocular pressure.

  18. Simple, reliable, and nondestructive method for the measurement of vacuum pressure without specialized equipment.

    Science.gov (United States)

    Yuan, Jin-Peng; Ji, Zhong-Hua; Zhao, Yan-Ting; Chang, Xue-Fang; Xiao, Lian-Tuan; Jia, Suo-Tang

    2013-09-01

    We present a simple, reliable, and nondestructive method for the measurement of vacuum pressure in a magneto-optical trap. The vacuum pressure is verified to be proportional to the collision rate constant between cold atoms and the background gas with a coefficient k, which can be calculated by means of the simple ideal gas law. The rate constant for loss due to collisions with all background gases can be derived from the total collision loss rate by a series of loading curves of cold atoms under different trapping laser intensities. The presented method is also applicable for other cold atomic systems and meets the miniaturization requirement of commercial applications.

  19. Modern gas-based temperature and pressure measurements

    CERN Document Server

    Pavese, Franco

    2013-01-01

    This 2nd edition volume of Modern Gas-Based Temperature and Pressure Measurements follows the first publication in 1992. It collects a much larger set of information, reference data, and bibliography in temperature and pressure metrology of gaseous substances, including the physical-chemical issues related to gaseous substances. The book provides solutions to practical applications where gases are used in different thermodynamic conditions. Modern Gas-Based Temperature and Pressure Measurements, 2nd edition is the only comprehensive survey of methods for pressure measurement in gaseous media used in the medium-to-low pressure range closely connected with thermometry. It assembles current information on thermometry and manometry that involve the use of gaseous substances which are likely to be valid methods for the future. As such, it is an important resource for the researcher. This edition is updated through the very latest scientific and technical developments of gas-based temperature and pressure measurem...

  20. A microwave pressure sounder. [for remote measurement of atmospheric pressure

    Science.gov (United States)

    Peckham, G. E.; Flower, D. A.

    1981-01-01

    A technique for the remote measurement of atmospheric surface pressure will be described. Such measurements could be made from a satellite in polar orbit and would cover many areas for which conventional meteorological data are not available. An active microwave instrument is used to measure the strength of return echoes from the ocean surface at a number of frequencies near the 60 GHz oxygen absorption band. Factors which affect the accuracy with which surface pressure can be deduced from these measurements will be discussed and an instrument designed to test the method by making measurements from an aircraft will be described.

  1. A fluid-structure interaction model of the internal carotid and ophthalmic arteries for the noninvasive intracranial pressure measurement method.

    Science.gov (United States)

    Misiulis, Edgaras; Džiugys, Algis; Navakas, Robertas; Striūgas, Nerijus

    2017-05-01

    Accurate and clinically safe measurements of intracranial pressure (ICP) are crucial for secondary brain damage prevention. There are two methods of ICP measurement: invasive and noninvasive. Invasive methods are clinically unsafe; therefore, safer noninvasive methods are being developed. One of the noninvasive ICP measurement methods implements the balance principle, which assumes that if the velocity of blood flow in both ophthalmic artery segments - the intracranial (IOA) and extracranial (EOA) - is equal, then the acting ICP on the IOA and the external pressure (Pe) on the EOA are also equal. To investigate the assumption of the balance principle, a generalized computational model incorporating a fluid-structure interaction (FSI) module was created and used to simulate noninvasive ICP measurement by accounting for the time-dependent behavior of the elastic internal carotid (ICA) and ophthalmic (OA) arteries and their interaction with pulsatile blood flow. It was found that the extra balance pressure term, which incorporates the hydrodynamic pressure drop between measurement points, must be added into the balance equation, and the corrections on a difference between the velocity of blood flow in the IOA and EOA must be made, due to a difference in the blood flow rate. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. The comparative analysis of the current-meter method and the pressure-time method used for discharge measurements in the Kaplan turbine penstocks

    Science.gov (United States)

    Adamkowski, A.; Krzemianowski, Z.

    2012-11-01

    The paper presents experiences gathered during many years of utilizing the current-meter and pressure-time methods for flow rate measurements in many hydropower plants. The integration techniques used in these both methods are different from the recommendations contained in the relevant international standards, mainly from the graphical and arithmetical ones. The results of the comparative analysis of both methods applied at the same time during the hydraulic performance tests of two Kaplan turbines in one of the Polish hydropower plant are presented in the final part of the paper. In the case of the pressure-time method application, the concrete penstocks of the tested turbines required installing a special measuring instrumentation inside the penstock. The comparison has shown a satisfactory agreement between the results of discharge measurements executed using the both considered methods. Maximum differences between the discharge values have not exceeded 1.0 % and the average differences have not been greater than 0.5 %.

  3. The comparative analysis of the current-meter method and the pressure-time method used for discharge measurements in the Kaplan turbine penstocks

    International Nuclear Information System (INIS)

    Adamkowski, A; Krzemianowski, Z

    2012-01-01

    The paper presents experiences gathered during many years of utilizing the current-meter and pressure-time methods for flow rate measurements in many hydropower plants. The integration techniques used in these both methods are different from the recommendations contained in the relevant international standards, mainly from the graphical and arithmetical ones. The results of the comparative analysis of both methods applied at the same time during the hydraulic performance tests of two Kaplan turbines in one of the Polish hydropower plant are presented in the final part of the paper. In the case of the pressure-time method application, the concrete penstocks of the tested turbines required installing a special measuring instrumentation inside the penstock. The comparison has shown a satisfactory agreement between the results of discharge measurements executed using the both considered methods. Maximum differences between the discharge values have not exceeded 1.0 % and the average differences have not been greater than 0.5 %.

  4. Uncertainties for pressure-time efficiency measurements

    OpenAIRE

    Ramdal, Jørgen; Jonsson, Pontus; Dahlhaug, Ole Gunnar; Nielsen, Torbjørn; Cervantes, Michel

    2010-01-01

     In connection with the pressure-time project at the Norwegian University of Science and Technology and Luleå University of Technology, a number of tests with the pressure-time method have been performed at the Waterpower Laboratory in Trondheim, Norway. The aim is to lower the uncertainty and improve usability of the method. Also a field test at the Anundsjoe power plant in Sweden has been performed. The pressure-time measurement is affected by random uncertainty. To minimize the effect of t...

  5. New intraocular pressure measurement method using reflected pneumatic pressure from cornea deformed by air puff of ring-type nozzle.

    Science.gov (United States)

    Kim, Hyung Jin; Seo, Yeong Ho; Kim, Byeong Hee

    2017-01-01

    In this study, a non-contact type intraocular pressure (IOP) measuring system using reflected pneumatic pressure is proposed to overcome the disadvantages of existing measurement systems. A ring-type nozzle, a key component in the proposed system, is designed via computational fluid analysis. It predicts the reflected pneumatic pressure based on the nozzle exit angle and inner and outer diameters of the nozzle, which are 30°, 7 mm, and 9 mm, respectively. Performance evaluation is conducted using artificial eyes fabricated using polydimethylsiloxane with the specifications of human eyes. The IOP of the fabricated artificial eyes is adjusted to 10, 30, and 50 mm Hg, and the reflected pneumatic pressure is measured as a function of the distance between the ring-type nozzle and artificial eye. The measured reflected pneumatic pressure is high when the measurement distance is short and eye pressure is low. The cornea of an artificial eye is significantly deformed at a low IOP, and the applied pneumatic pressure is more concentrated in front of the ring-type nozzle because of the deformed cornea. Thus, the reflected pneumatic pressure at a low IOP has more inflows into the pressure sensor inserted inside the nozzle. The sensitivity of the output based on the IOP at measurement distances between 3-5 mm is -0.0027, -0.0022, -0.0018, -0.0015, and -0.0012. Sensitivity decreases as the measurement distance increases. In addition, the reflected pneumatic pressure owing to the misalignment at the measurement distances of 3-5 mm is not affected within a range of 0.5 mm. Therefore, the measurement range is acceptable up to a 1 mm diameter from the center of an artificial eye. However, the accuracy gradually decreases as the reflected pneumatic pressure from a misalignment of 1 mm or more decreases by 26% or more.

  6. Auscultatory versus oscillometric measurement of blood pressure in octogenarians

    DEFF Research Database (Denmark)

    Rosholm, Jens-Ulrik; Pedersen, Sidsel Arnspang; Matzen, Lars

    2012-01-01

    Auscultatory measurement using a sphygmomanometer has been the predominant method for clinical estimation of blood pressure, but it is now rapidly being replaced by oscillometric measurement.......Auscultatory measurement using a sphygmomanometer has been the predominant method for clinical estimation of blood pressure, but it is now rapidly being replaced by oscillometric measurement....

  7. Measurement correction method for force sensor used in dynamic pressure calibration based on artificial neural network optimized by genetic algorithm

    Science.gov (United States)

    Gu, Tingwei; Kong, Deren; Shang, Fei; Chen, Jing

    2017-12-01

    We present an optimization algorithm to obtain low-uncertainty dynamic pressure measurements from a force-transducer-based device. In this paper, the advantages and disadvantages of the methods that are commonly used to measure the propellant powder gas pressure, the applicable scope of dynamic pressure calibration devices, and the shortcomings of the traditional comparison calibration method based on the drop-weight device are firstly analysed in detail. Then, a dynamic calibration method for measuring pressure using a force sensor based on a drop-weight device is introduced. This method can effectively save time when many pressure sensors are calibrated simultaneously and extend the life of expensive reference sensors. However, the force sensor is installed between the drop-weight and the hammerhead by transition pieces through the connection mode of bolt fastening, which causes adverse effects such as additional pretightening and inertia forces. To solve these effects, the influence mechanisms of the pretightening force, the inertia force and other influence factors on the force measurement are theoretically analysed. Then a measurement correction method for the force measurement is proposed based on an artificial neural network optimized by a genetic algorithm. The training and testing data sets are obtained from calibration tests, and the selection criteria for the key parameters of the correction model is discussed. The evaluation results for the test data show that the correction model can effectively improve the force measurement accuracy of the force sensor. Compared with the traditional high-accuracy comparison calibration method, the percentage difference of the impact-force-based measurement is less than 0.6% and the relative uncertainty of the corrected force value is 1.95%, which can meet the requirements of engineering applications.

  8. Extremely-high vacuum pressure measurement by laser ionization

    International Nuclear Information System (INIS)

    Kokubun, Kiyohide

    1991-01-01

    Laser ionization method has the very high sensitivity for detecting atoms and molecules. Hurst et al. successfully detected a single Cs atom by means of resonance ionization spectroscopy developed by them. Noting this high sensitivity, the authors have attempted to apply the laser ionization method to measure gas pressure, particularly in the range down to extremely high vacuum. At present, hot cathode ionization gauges are used for measuring gas pressure down to ultrahigh vacuum, however, those have a number of disadvantages. The pressure measurement using lasers does not have such disadvantages. The pressure measurement utilizing the laser ionization method is based on the principle that when laser beam is focused through a lens, the amount of atom or molecule ions generated in the focused space region is proportional to gas pressure. In this paper, the experimental results are presented on the nonresonant multiphoton ionization characteristics of various kinds of gases, the ion detection system with high sensitivity and an extremely high vacuum system prepared for the laser ionization experiment. (K.I.)

  9. Line pressure effects on differential pressure measurements

    International Nuclear Information System (INIS)

    Neff, G.G.; Evans, R.P.

    1982-01-01

    The performance of differential pressure transducers in experimental pressurized water reactor (PWR) systems was evaluated. Transient differential pressure measurements made using a simple calibration proportionality relating differential pressure to output voltage could have large measurement uncertainties. A more sophisticated calibration equation was derived to incorporate the effects of zero shifts and sensitivity shifts as pressure in the pressure sensing line changes with time. A comparison made between the original calibration proportionality equation and the derived compensation equation indicates that potential measurement uncertainties can be reduced

  10. [Invasive arterial blood pressure measurement using an aneroid pressure system in cattle].

    Science.gov (United States)

    Mosing, M; Franz, S; Iff, I; Schwendenwein, I

    2009-06-01

    The aim of this study was to compare the results of invasive arterial blood pressure measurement using an electronic pressure transducer (EPT) or an aneroid pressure system (APS) in cattle. A catheter was placed in the auricular artery of 11 adult cattle and connected to a pressure transducer via pressure line. The aneroid system was connected to the same catheter using a three-way stop-cock in the pressure line. On five occasions three consecutive measurements were performed with the APS. The mean blood pressure values of the EPT were recorded before each individual measurement. Values from each device were compared using Passing and Bablok regression of agreement and a Bland and Altman difference plot. One hundred and forty-seven paired measurements were analysed. The average bias between the two methods (EPT vs. APS) was -1.6 mmHg (95 % confidence interval [CI]: -3.0 to -0.2 mmHg). The coefficient of correlation was 1.0084. The aneroid system showed an almost perfect agreement with the EPT. This study shows that it can be used in a clinical setting as well as under field conditions to measure arterial blood pressure in cattle.

  11. A method for measuring the local gas pressure within a gas-flow stage in situ in the transmission electron microscope

    International Nuclear Information System (INIS)

    Colby, R.; Alsem, D.H.; Liyu, A.; Kabius, B.

    2015-01-01

    Environmental transmission electron microscopy (TEM) has enabled in situ experiments in a gaseous environment with high resolution imaging and spectroscopy. Addressing scientific challenges in areas such as catalysis, corrosion, and geochemistry can require pressures much higher than the ∼20 mbar achievable with a differentially pumped environmental TEM. Gas flow stages, in which the environment is contained between two semi-transparent thin membrane windows, have been demonstrated at pressures of several atmospheres. However, the relationship between the pressure at the sample and the pressure drop across the system is not clear for some geometries. We demonstrate a method for measuring the gas pressure at the sample by measuring the ratio of elastic to inelastic scattering and the defocus of the pair of thin windows. This method requires two energy filtered high-resolution TEM images that can be performed during an ongoing experiment, at the region of interest. The approach is demonstrated to measure greater than atmosphere pressures of N 2 gas using a commercially available gas-flow stage. This technique provides a means to ensure reproducible sample pressures between different experiments, and even between very differently designed gas-flow stages. - Highlights: • Method developed for measuring gas pressure within a gas-flow stage in the TEM. • EFTEM and CTF-fitting used to calculate amount and volume of gas. • Requires only a pair of images without leaving region of interest. • Demonstrated for P > 1 atm with a common commercial gas-flow stage

  12. On output measurements via radiation pressure

    DEFF Research Database (Denmark)

    Leeman, S.; Healey, A.J.; Forsberg, F.

    1990-01-01

    It is shown, by simple physical argument, that measurements of intensity with a radiation pressure balance should not agree with those based on calorimetric techniques. The conclusion is ultimately a consequence of the circumstance that radiation pressure measurements relate to wave momentum, while...... calorimetric methods relate to wave energy. Measurements with some typical ultrasound fields are performed with a novel type of hydrophone, and these allow an estimate to be made of the magnitude of the discrepancy to be expected between the two types of output measurement in a typical case....

  13. Dynamic pressure sensitivity determination with Mach number method

    Science.gov (United States)

    Sarraf, Christophe; Damion, Jean-Pierre

    2018-05-01

    Measurements of pressure in fast transient conditions are often performed even if the dynamic characteristic of the transducer are not traceable to international standards. Moreover, the question of a primary standard in dynamic pressure is still open, especially for gaseous applications. The question is to improve dynamic standards in order to respond to expressed industrial needs. In this paper, the method proposed in the EMRP IND09 ‘Dynamic’ project, which can be called the ‘ideal shock tube method’, is compared with the ‘collective standard method’ currently used in the Laboratoire de Métrologie Dynamique (LNE/ENSAM). The input is a step of pressure generated by a shock tube. The transducer is a piezoelectric pressure sensor. With the ‘ideal shock tube method’ the sensitivity of a pressure sensor is first determined dynamically. This method requires a shock tube implemented with piezoelectric shock wave detectors. The measurement of the Mach number in the tube allows an evaluation of the incident pressure amplitude of a step using a theoretical 1D model of the shock tube. Heat transfer, other actual effects and effects of the shock tube imperfections are not taken into account. The amplitude of the pressure step is then used to determine the sensitivity in dynamic conditions. The second method uses a frequency bandwidth comparison to determine pressure at frequencies from quasi-static conditions, traceable to static pressure standards, to higher frequencies (up to 10 kHz). The measurand is also a step of pressure generated by a supposed ideal shock tube or a fast-opening device. The results are provided as a transfer function with an uncertainty budget assigned to a frequency range, also deliverable frequency by frequency. The largest uncertainty in the bandwidth of comparison is used to trace the final pressure step level measured in dynamic conditions, owing that this pressure is not measurable in a steady state on a shock tube. A reference

  14. Pressure Measurement Systems

    Science.gov (United States)

    1990-01-01

    System 8400 is an advanced system for measurement of gas and liquid pressure, along with a variety of other parameters, including voltage, frequency and digital inputs. System 8400 offers exceptionally high speed data acquisition through parallel processing, and its modular design allows expansion from a relatively inexpensive entry level system by the addition of modular Input Units that can be installed or removed in minutes. Douglas Juanarena was on the team of engineers that developed a new technology known as ESP (electronically scanned pressure). The Langley ESP measurement system was based on miniature integrated circuit pressure-sensing transducers that communicated pressure information to a minicomputer. In 1977, Juanarena formed PSI to exploit the NASA technology. In 1978 he left Langley, obtained a NASA license for the technology, introduced the first commercial product, the 780B pressure measurement system. PSI developed a pressure scanner for automation of industrial processes. Now in its second design generation, the DPT-6400 is capable of making 2,000 measurements a second and has 64 channels by addition of slave units. New system 8400 represents PSI's bid to further exploit the 600 million U.S. industrial pressure measurement market. It is geared to provide a turnkey solution to physical measurement.

  15. Microalbuminuria Measured by three Different Methods, Blood Pressure and Cardiovascular Risk Factors in Elderly Swedish Males

    Directory of Open Access Journals (Sweden)

    Gösta Florvall

    2008-01-01

    Full Text Available Microalbuminuria is associated with hypertension and is a strong risk factor for subsequent chronic disease, both renal and coronary heart disease (CHD, Presently there are several methods available for measurement of microalbuminuria. The aim of this study was to evaluate if the three different methods gave similar information or if one of the assays were superior to the others. Blood pressure, inflammatory markers and cardiovascular mortality and morbidity were correlated with urine albumin analysed with a point-of-care testing (POCT instrument, nephelometric determination of albumin and albumin/creatinine ratio in elderly males. The study population consisted of 103 diabetic and 603 nondiabetic males (age 77 years in a cross-sectional study. We analyzed urine albumin with a HemoCue® Urine Albumin POCT instrument and a ProSpec® nephelometer and albumin/creatinine ratio. There were strong correlations between both systolic and diastolic blood pressure and all three urine albumin methods (p < 0.0001. There were also significant correlations between the different urine albumin measurements and serum amyloid A component, high-sensitivity C-reactive protein and interleukin-6. The three different urine albumin methods studied provided similar information in relation to cardiovascular disease. There was a strong correlation between systolic and diastolic blood pressure and microalbuminuria in both the whole study population and in nondiabetic males emphasizing the role of hypertension in glomerular damage. The good correlation between the studied urine albumin measurements show that all three methods can be used for monitoring urine albumin excretion.

  16. Quantitative assessment of corneal vibrations during intraocular pressure measurement with the air-puff method in patients with keratoconus.

    Science.gov (United States)

    Koprowski, Robert; Ambrósio, Renato

    2015-11-01

    One of the current methods for measuring intraocular pressure is the air-puff method. A tonometer which uses this method is the Corvis device. With the ultra-high-speed (UHS) Scheimpflug camera, it is also possible to observe corneal deformation during measurement. The use of modern image analysis and processing methods allows for analysis of higher harmonics of corneal deflection above 100 Hz. 493 eyes of healthy subjects and 279 eyes of patients with keratoconus were used in the measurements. For each eye, 140 corneal deformation images were recorded during intraocular pressure measurement. Each image was recorded every 230 µs and had a resolution of 200 × 576 pixels. A new, original algorithm for image analysis and processing has been proposed. It enables to separate the eyeball reaction as well as low-frequency and high-frequency corneal deformations from the eye response to an air puff. Furthermore, a method for classification of healthy subjects and patients with keratoconus based on decision trees has been proposed. The obtained results confirm the possibility to distinguish between patients with keratoconus and healthy subjects. The features used in this classification are directly related to corneal vibrations. They are only available in the proposed software and provide specificity of 98%, sensitivity-85%, and accuracy-92%. This confirms the usefulness of the proposed method in this type of classification that uses corneal vibrations during intraocular pressure measurement with the Corvis tonometer. With the new proposed algorithm for image analysis and processing allowing for the separation of individual features from a corneal deformation image, it is possible to: automatically measure corneal vibrations in a few characteristic points of the cornea, obtain fully repeatable measurement of vibrations for the same registered sequence of images and measure vibration parameters for large inter-individual variability in patients. Copyright © 2015 Elsevier

  17. MEASUREMENT OF FRICTIONAL PRESSURE DIFFERENTIALS DURING A VENTILATION SURVEY

    International Nuclear Information System (INIS)

    B.S. Prosser, PE; I.M. Loomis, PE, PhD

    2003-01-01

    During the course of a ventilation survey, both airflow quantity and frictional pressure losses are measured and quantified. The measurement of airflow has been extensively studied as the vast majority of ventilation standards/regulations are tied to airflow quantity or velocity. However, during the conduct of a ventilation survey, measurement of airflow only represents half of the necessary parameters required to directly calculate the airway resistance. The measurement of frictional pressure loss is an often misunderstood and misapplied part of the ventilation survey. This paper compares the two basic methods of frictional pressure drop measurements; the barometer and the gauge and tube. Personal experiences with each method will be detailed along with the authors' opinions regarding the applicability and conditions favoring each method

  18. Measurement of intraocular pressure with pressure phosphene tonometry in children.

    Science.gov (United States)

    Fan, Dorothy S P; Chiu, Thomas Y H; Congdon, Nathan; Chan, Jeffrey C W; Cheung, Eva Y Y; Lam, Dennis S C

    2011-01-01

    To study the accuracy and acceptability of intraocular pressure (IOP) measurement by the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer in children. Fifty children (5 to 14 years old) participated in this prospective comparative study. IOP was measured with the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer by three different examiners who were masked to the results. The children were also asked to grade the degree of discomfort from 0 to 5 (0 = no discomfort; 5 = most discomfort). The mean IOPs measured by the Goldmann tonometer, pressure phosphene tonometer, and non-contact tonometer were 15.9 mm Hg (standard deviation [SD]: = 5.5 mm Hg; range: 10 to 36 mm Hg), 16.0 mm Hg (SD: 2.9 mm Hg; range: 12 to 25 mm Hg), and 15.7 mm Hg (SD = 5.1 mm Hg; range: 8 to 32 mm Hg), respectively (P = .722). The mean difference between pressure phosphene tonometer and Goldmann tonometer readings was 2.9 mm Hg and that between non-contact tonometer and Goldmann tonometer readings was 2.1 mm Hg. The 95% confidence interval of the mean difference between pressure phosphene tonometer and Goldmann tonometer readings was -1.07 and 1.19, and that between non-contact tonometer and Goldmann tonometer readings was -1.07 and 0.53. The mean discomfort ratings for the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer were 0.6, 2.0, and 2.3, respectively (P tonometer was less accurate than the non-contact tonometer compared with Goldmann tonometer, it gave a reasonably close estimate and had a high specificity of raised IOP. In addition, measurement by the pressure phosphene tonometer is most acceptable to children. The pressure phosphene tonometer can be considered as an alternative method of IOP measurement in children. Copyright 2011, SLACK Incorporated.

  19. Oscillometric blood pressure measurements: differences between measured and calculated mean arterial pressure.

    NARCIS (Netherlands)

    Kiers, H.D.; Hofstra, J.M.; Wetzels, J.F.M.

    2008-01-01

    Mean arterial pressure (MAP) is often used as an index of overall blood pressure. In recent years, the use of automated oscillometric blood pressure measurement devices is increasing. These devices directly measure and display MAP; however, MAP is often calculated from systolic blood pressure (SBP)

  20. Intraocular pressure measurement in patients with previous LASIK surgery using pressure phosphene tonometer.

    Science.gov (United States)

    Cheng, Arthur C K; Leung, Dexter Y L; Cheung, Eva Y Y; Fan, Dorothy S P; Law, Ricky W K; Lam, Dennis S C

    2005-04-01

    To compare intraocular pressure (IOP) assessment in post-LASIK patients using non-contact tonometry, pressure phosphene tonometry and applanation tonometry. Sixty-two consecutive LASIK patients were analysed preoperatively and postoperatively with non-contact, pressure phosphene and applanation tonometry. Comparisons among these values were assessed with paired sample Student t-test, Pearson's correlation test and Bland-Altman plotting. There was no significant difference for preoperative IOP measurement between non-contact, pressure phosphene and applanation tonometry. The mean +/-SD difference between the preoperative non-contact tonometry and postoperative pressure phosphene tonometry IOP measurements was 0.80 +/- 2.77 mmHg (P contact tonometry significantly underestimated IOP measurement by 9.96 +/- 2.25 mmHg (P < 0.001). Pressure phosphene tonometry may provide an alternative method for the assessment of IOP in post-LASIK patients.

  1. Assessing Pharmacy Students’ Ability to Accurately Measure Blood Pressure Using a Blood Pressure Simulator Arm

    Science.gov (United States)

    Bryant, Ginelle A.; Haack, Sally L.; North, Andrew M.

    2013-01-01

    Objective. To compare student accuracy in measuring normal and high blood pressures using a simulator arm. Methods. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. Results. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; pdifference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Conclusions. Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign. PMID:23788809

  2. Noninvasive microbubble-based pressure measurements: a simulation study

    NARCIS (Netherlands)

    Postema, Michiel; Postema, M.A.B.; Bouakaz, Ayache; de Jong, N.

    2004-01-01

    This paper describes a noninvasive method to measure local hydrostatic pressures in fluid filled cavities. The method is based on the disappearance time of a gas bubble, as the disappearance time is related to the hydrostatic pressure. When a bubble shrinks, its response to ultrasound changes. From

  3. Pico gauges for minimally invasive intracellular hydrostatic pressure measurements

    DEFF Research Database (Denmark)

    Knoblauch, Jan; Mullendore, Daniel L.; Jensen, Kaare Hartvig

    2014-01-01

    Intracellular pressure has a multitude of functions in cells surrounded by a cell wall or similar matrix in all kingdoms of life. The functions include cell growth, nastic movements, and penetration of tissue by parasites. The precise measurement of intracellular pressure in the majority of cells......, however, remains difficult or impossible due to their small size and/or sensitivity to manipulation. Here, we report on a method that allows precise measurements in basically any cell type over all ranges of pressure. It is based on the compression of nanoliter and picoliter volumes of oil entrapped...... in the tip of microcapillaries, which we call pico gauges. The production of pico gauges can be accomplished with standard laboratory equipment, and measurements are comparably easy to conduct. Example pressure measurements are performed on cells that are difficult or impossible to measure with other methods....

  4. Method of detecting leakage from sealing attached to pressure tube

    International Nuclear Information System (INIS)

    Tomomatsu, Ken-ichi; Hayashi, Ken-ichi.

    1990-01-01

    The present invention provides a detection method for measuring the amount of water leaked from sealings attached to the lower end of a pressure tube. That is, the lower end of the pressure tube is sealed only by a metal sealing. A capturing vessel is placed under the pressure tube for capturing the leaked water dropping from the lower end of the pressure tube and the weight of the leaked water is measured on every capturing vessels to determine the amount of the leaked water. The leakage detection method based on the weight measurement has higher accuracy compared with a conventional volume measuring method using a water level gauge as described below. For example, if the volume of the captured water is 10cc, an error of about 0.1cc is caused by the volume measuring method using the water level gauge, whereas if 10g (10cc) weight of water is measured by using an accurate balance, error is only about 10 -4 g (10 -4 cc). Accordingly, the method of the present invention can measure at an accuracy about 1000 times as high as the conventional method. (I.S.)

  5. MEthods of ASsessing blood pressUre: identifying thReshold and target valuEs (MeasureBP): a review & study protocol.

    Science.gov (United States)

    Blom, Kimberly C; Farina, Sasha; Gomez, Yessica-Haydee; Campbell, Norm R C; Hemmelgarn, Brenda R; Cloutier, Lyne; McKay, Donald W; Dawes, Martin; Tobe, Sheldon W; Bolli, Peter; Gelfer, Mark; McLean, Donna; Bartlett, Gillian; Joseph, Lawrence; Featherstone, Robin; Schiffrin, Ernesto L; Daskalopoulou, Stella S

    2015-04-01

    Despite progress in automated blood pressure measurement (BPM) technology, there is limited research linking hard outcomes to automated office BPM (OBPM) treatment targets and thresholds. Equivalences for automated BPM devices have been estimated from approximations of standardized manual measurements of 140/90 mmHg. Until outcome-driven targets and thresholds become available for automated measurement methods, deriving evidence-based equivalences between automated methods and standardized manual OBPM is the next best solution. The MeasureBP study group was initiated by the Canadian Hypertension Education Program to close this critical knowledge gap. MeasureBP aims to define evidence-based equivalent values between standardized manual OBPM and automated BPM methods by synthesizing available evidence using a systematic review and individual subject-level data meta-analyses. This manuscript provides a review of the literature and MeasureBP study protocol. These results will lay the evidenced-based foundation to resolve uncertainties within blood pressure guidelines which, in turn, will improve the management of hypertension.

  6. Smartphone-based Continuous Blood Pressure Measurement Using Pulse Transit Time.

    Science.gov (United States)

    Gholamhosseini, Hamid; Meintjes, Andries; Baig, Mirza; Linden, Maria

    2016-01-01

    The increasing availability of low cost and easy to use personalized medical monitoring devices has opened the door for new and innovative methods of health monitoring to emerge. Cuff-less and continuous methods of measuring blood pressure are particularly attractive as blood pressure is one of the most important measurements of long term cardiovascular health. Current methods of noninvasive blood pressure measurement are based on inflation and deflation of a cuff with some effects on arteries where blood pressure is being measured. This inflation can also cause patient discomfort and alter the measurement results. In this work, a mobile application was developed to collate the PhotoPlethysmoGramm (PPG) waveform provided by a pulse oximeter and the electrocardiogram (ECG) for calculating the pulse transit time. This information is then indirectly related to the user's systolic blood pressure. The developed application successfully connects to the PPG and ECG monitoring devices using Bluetooth wireless connection and stores the data onto an online server. The pulse transit time is estimated in real time and the user's systolic blood pressure can be estimated after the system has been calibrated. The synchronization between the two devices was found to pose a challenge to this method of continuous blood pressure monitoring. However, the implemented continuous blood pressure monitoring system effectively serves as a proof of concept. This combined with the massive benefits that an accurate and robust continuous blood pressure monitoring system would provide indicates that it is certainly worthwhile to further develop this system.

  7. Blood pressure measurement method and inter-arm differences: a meta-analysis.

    Science.gov (United States)

    Verberk, Willem J; Kessels, Alfons G H; Thien, Theo

    2011-11-01

    Screening for inter-arm difference (IAD) of blood pressure (BP) at each first visit is recommended by numerous guidelines whereas it is unclear whether the method by which IAD is measured has significant influence on the IAD value. A systematic review is made of the studies reporting on double-arm measurements and the association of IAD with procedure characteristics (Medline/PubMed, Embase, and Cochrane Library). The mean absolute IAD was 5.4 ± 1.7 and 3.6 ± 1.2 mm Hg for systolic and diastolic BP, respectively. Of all subjects 14% had a systolic IAD ≥10 mm Hg, 4% a systolic IAD ≥20 mm Hg, and 7% a diastolic IAD ≥10 mm Hg. The relative risk (RR) of obtaining a systolic IAD ≥10 and 20 mm Hg and a diastolic IAD ≥10 mm Hg is higher when measuring sequentially instead of simultaneously (2.2 (95% CI: 1.4-3.6), P arms, with one or two automatic devices and multiple readings should be taken.

  8. Urethral pressure reflectometry. A method for simultaneous measurements of pressure and cross-sectional area in the female urethra

    DEFF Research Database (Denmark)

    Klarskov, Niels

    2012-01-01

    A novel technique for simultaneous measurements of pressure and cross-sectional area (CA) in the female urethra, denoted Urethral Pressure Reflectometry (UPR), was devised. A very thin and highly flexible polyurethane-bag was placed in the urethra. A pump applied increasing and decreasing pressur...

  9. Simplified pressure method for respirator fit testing.

    Science.gov (United States)

    Han, D; Xu, M; Foo, S; Pilacinski, W; Willeke, K

    1991-08-01

    A simplified pressure method has been developed for fit testing air-purifying respirators. In this method, the air-purifying cartridges are replaced by a pressure-sensing attachment and a valve. While wearers hold their breath, a small pump extracts air from the respirator cavity until a steady-state pressure is reached in 1 to 2 sec. The flow rate through the face seal leak is a unique function of this pressure, which is determined once for all respirators, regardless of the respirator's cavity volume or deformation because of pliability. The contaminant concentration inside the respirator depends on the degree of dilution by the flow through the cartridges. The cartridge flow varies among different brands and is measured once for each brand. The ratio of cartridge to leakflow is a measure of fit. This flow ratio has been measured on human subjects and has been compared to fit factors determined on the same subjects by means of photometric and particle count tests. The aerosol tests gave higher values of fit.

  10. Development of the pressure-time method as a relative and absolute method for low-head hydraulic machines

    Energy Technology Data Exchange (ETDEWEB)

    Jonsson, Pontus [Poeyry SwedPower AB, Stockholm (Sweden); Cervantes, Michel [Luleaa Univ. of Technology, Luleaa (Sweden)

    2013-02-15

    The pressure-time method is an absolute method common for flow measurements in power plants. The method determines the flow rate by measuring the pressure and estimating the losses between two sections in the penstock during a closure of the guide vanes. The method has limitations according to the IEC41 standard, which makes it difficult to use at Swedish plants where the head is generally low. This means that there is limited experience/knowledge in Sweden on this method, where the Winter-Kennedy is usually used. Since several years, Luleaa University of Technology works actively in the development of the pressure-time method for low-head hydraulic machines with encouraging results. Focus has been in decreasing the distance between both measuring sections and evaluation of the viscous losses. Measurements were performed on a pipe test rig (D=0.3 m) in a laboratory under well controlled conditions with 7pressure-time measurements (with L=5 m) performed on a 10 MW Kaplan turbine compared to transit-time flow measurements. The new formulation taking into account the unsteady losses allows a better estimation of the flow rate, up to 0.3%. As an alternative to the Winter-Kennedy widely used in Sweden, the pressure-time method was tested as a relative method by measuring the pressure between the free surface and a section in the penstock without knowing the exact geometry, i.e., pipe factor. Such measurements may be simple to perform as most of the inlet spiral casings have pressure taps. Furthermore, the viscous losses do not need to be accurately determined as long as they are handled similarly between the measurements. The pressure-time method may thus become an alternative to the Winter-Kennedy.

  11. High pressure changes of the castor oil viscosity by ultrasonic method

    International Nuclear Information System (INIS)

    Rostocki, A J; Siegoczynski, R M; Kielczynski, P; Szalewski, M

    2008-01-01

    The pressure change of viscosity of castor oil have been measured by ultrasonic method within the range of pressure up to 0.9 GPa. For the measurement, the authors have applied a new ultrasonic method based on Bleustein-Gulyaev (B-G) waves. For the lower pressures (up to 0.3 GPa) the results have been compared with earlier results obtained by falling body method, whereas for the higher pressure range results were compared with those obtained by the flow type viscometer. The measurements have shown: 1. Exponential rise of viscosity with pressure up to 0.4 GPa according to the Barus formula. 2. Extraordinary increment of viscosity at constant pressure during phase transition. 3. The decomposition of the high pressure phase during the decompression process have shown very large hysteresis of viscosity on pressure. 4. After the decompression process the viscosity lasts higher then a initial value for several hours

  12. In situ high-pressure measurement of crystal solubility by using neutron diffraction

    Science.gov (United States)

    Chen, Ji; Hu, Qiwei; Fang, Leiming; He, Duanwei; Chen, Xiping; Xie, Lei; Chen, Bo; Li, Xin; Ni, Xiaolin; Fan, Cong; Liang, Akun

    2018-05-01

    Crystal solubility is one of the most important thermo-physical properties and plays a key role in industrial applications, fundamental science, and geoscientific research. However, high-pressure in situ measurements of crystal solubility remain very challenging. Here, we present a method involving high-pressure neutron diffraction for making high-precision in situ measurements of crystal solubility as a function of pressure over a wide range of pressures. For these experiments, we designed a piston-cylinder cell with a large chamber volume for high-pressure neutron diffraction. The solution pressures are continuously monitored in situ based on the equation of state of the sample crystal. The solubility at a high pressure can be obtained by applying a Rietveld quantitative multiphase analysis. To evaluate the proposed method, we measured the high-pressure solubility of NaCl in water up to 610 MPa. At a low pressure, the results are consistent with the previous results measured ex situ. At a higher pressure, more reliable data could be provided by using an in situ high-pressure neutron diffraction method.

  13. Measurement of compartment elasticity using pressure related ultrasound: a method to identify patients with potential compartment syndrome.

    Science.gov (United States)

    Sellei, R M; Hingmann, S J; Kobbe, P; Weber, C; Grice, J E; Zimmerman, F; Jeromin, S; Gansslen, A; Hildebrand, F; Pape, H C

    2015-01-01

    PURPOSE OF THE STUDY Decision-making in treatment of an acute compartment syndrome is based on clinical assessment, supported by invasive monitoring. Thus, evolving compartment syndrome may require repeated pressure measurements. In suspected cases of potential compartment syndromes clinical assessment alone seems to be unreliable. The objective of this study was to investigate the feasibility of a non-invasive application estimating whole compartmental elasticity by ultrasound, which may improve accuracy of diagnostics. MATERIAL AND METHODS In an in-vitro model, using an artificial container simulating dimensions of the human anterior tibial compartment, intracompartmental pressures (p) were raised subsequently up to 80 mm Hg by infusion of saline solution. The compartmental depth (mm) in the cross-section view was measured before and after manual probe compression (100 mm Hg) upon the surface resulting in a linear compartmental displacement (Δd). This was repeated at rising compartmental pressures. The resulting displacements were related to the corresponding intra-compartmental pressures simulated in our model. A hypothesized relationship between pressures related compartmental displacement and the elasticity at elevated compartment pressures was investigated. RESULTS With rising compartmental pressures, a non-linear, reciprocal proportional relation between the displacement (mm) and the intra-compartmental pressure (mm Hg) occurred. The Pearson's coefficient showed a high correlation (r2 = -0.960). The intraobserver reliability value kappa resulted in a statistically high reliability (κ = 0.840). The inter-observer value indicated a fair reliability (κ = 0.640). CONCLUSIONS Our model reveals that a strong correlation between compartmental strain displacements assessed by ultrasound and the intra-compartmental pressure changes occurs. Further studies are required to prove whether this assessment is transferable to human muscle tissue. Determining the complete

  14. Ionic conductivity measurements of zirconia under pressure using impedance spectroscopy

    International Nuclear Information System (INIS)

    Takebe, H; Sakamoto, D; Ohtaka, O; Fukui, H; Yoshiasa, A; Yamanaka, T; Ota, K; Kikegawa, T

    2002-01-01

    We have set up an electrical conductivity measurement system under high-pressure and high-temperature conditions with a multi-anvil high-pressure apparatus using an AC complex impedance method. With this system, we have successfully measured the electrical conductivity of stabilized ZrO 2 (Y 2 O 3 -ZrO 2 solid solution) under pressures up to 5 GPa in the temperature range from 300 to 1200 K. The electrical conductivities obtained under pressure are compatible with those of previous results measured at ambient pressure

  15. [Comparison of invasive blood pressure measurement in the aorta with indirect oscillometric blood pressure measurement at the wrist and forearm].

    Science.gov (United States)

    Saul, F; Aristidou, Y; Klaus, D; Wiemeyer, A; Lösse, B

    1995-09-01

    Indirectly measured blood pressure at the wrist or upper arm was compared with directly measured values in the aortic arch during routinely performed diagnostic cardiac catheterization in 100 patients (31-80 years, mean 59.3 years, 60% males). The noninvasive measurements were carried out by oscillometric devices, NAiS Blood Pressure Watch for measurements at the wrist, and Hestia OZ80 at the upper arm. Systolic blood pressure measured at the wrist was 4.3 +/- 14.1 mm Hg, and the diastolic value 6.0 +/- 8.9 mm Hg higher than when measured at the aortic arch; the difference was significant in both cases. Correlation coefficients were 0.85 for systolic and 0.71 for diastolic blood pressure. In 16% of the patients the systolic blood pressure at the wrist differed more than +/- 20 mm Hg. The diastolic blood pressure at the wrist measured more than +/- 20 mm Hg higher than in the aorta in 5% of the patients. At the upper arm mean systolic values were not different to the aorta. The diastolic pressure was 9.3 +/- 9.8 mm Hg higher in the aorta than at the upper arm. To verify the accuracy of values measured with the NAiS Blood Pressure Watch compared with the standard technique at the upper arm, sequential measurements were made at wrist and ipsilateral upper arm in the same group of 100 patients. The systolic blood pressure at the left wrist was 3.4 +/- 13.3 mm Hg higher and the diastolic pressure 3.8 +/- 9.5 mm Hg lower than at the upper arm. Only 53% of systolic values lay within a range of +/- 10 mm Hg. The correspondence between wrist and upper arm values was better for diastolic blood pressure, the values differing by less than +/- 10 mm Hg in two-thirds of patients. Self-measurement of arterial blood pressure with an oscillometric device at the wrist can be recommended only in individual cases with a difference of simultaneously measured values at the upper arm of less than +/- 10 mm Hg for systolic and diastolic blood pressures. The standard method for indirectly

  16. Hepatic venous pressure gradients measured by duplex ultrasound

    International Nuclear Information System (INIS)

    Tasu, J.-P.; Rocher, L.; Peletier, G.; Kuoch, V.; Kulh, E.; Miquel, A.; Buffet, C.; Biery, M.

    2002-01-01

    AIMS: The hepatic venous pressure gradient is a major prognostic factor in portal hypertension but its measurement is complex and requires invasive angiography. This study investigated the relationship between the hepatic venous pressure gradient and a number of Doppler measurements, including the arterial acceleration index. METHOD: We measured the hepatic venous pressure gradient in 50 fasting patients at hepatic venography. Immediately afterwards, a duplex sonographic examination of the liver was performed at which multiple measurements and indices of the venous and arterial hepatic vasculature were made. RESULTS: Hepatic arterial acceleration was correlated directly with the hepatic venous pressure gradient (r = 0.83, P -2 provided a positive predictive value of 95%, a sensitivity of 65% and a specificity of 95% for detecting patients with severe portal hypertension (hepatic venous pressure gradient > 12 mmHg). A correlation between the hepatic venous pressure gradient and the congestion index of the portal vein velocity (r = 0.45,P = 0.01) and portal vein velocity (r = 0.40,P = 0.044), was also noted. CONCLUSION: Measuring the hepatic arterial acceleration index may help in the non-invasive evaluation of portal hypertension. Tasu, J.-P. et al. (2002)

  17. Peripheral vascular effects on auscultatory blood pressure measurement.

    Science.gov (United States)

    Rabbany, S Y; Drzewiecki, G M; Noordergraaf, A

    1993-01-01

    Experiments were conducted to examine the accuracy of the conventional auscultatory method of blood pressure measurement. The influence of the physiologic state of the vascular system in the forearm distal to the site of Korotkoff sound recording and its impact on the precision of the measured blood pressure is discussed. The peripheral resistance in the arm distal to the cuff was changed noninvasively by heating and cooling effects and by induction of reactive hyperemia. All interventions were preceded by an investigation of their effect on central blood pressure to distinguish local effects from changes in central blood pressure. These interventions were sufficiently moderate to make their effect on central blood pressure, recorded in the other arm, statistically insignificant (i.e., changes in systolic [p cooling experiments was statistically significant (p < 0.001). Moreover, both measured systolic (p < 0.004) and diastolic (p < 0.001) pressure decreases during the reactive hyperemia experiments were statistically significant. The findings demonstrate that alteration in vascular state generates perplexing changes in blood pressure, hence confirming experimental observations by earlier investigators as well as predictions by our model studies.

  18. Method and Apparatus for Characterizing Pressure Sensors using Modulated Light Beam Pressure

    Science.gov (United States)

    Youngquist, Robert C. (Inventor)

    2003-01-01

    Embodiments of apparatuses and methods are provided that use light sources instead of sound sources for characterizing and calibrating sensors for measuring small pressures to mitigate many of the problems with using sound sources. In one embodiment an apparatus has a light source for directing a beam of light on a sensing surface of a pressure sensor for exerting a force on the sensing surface. The pressure sensor generates an electrical signal indicative of the force exerted on the sensing surface. A modulator modulates the beam of light. A signal processor is electrically coupled to the pressure sensor for receiving the electrical signal.

  19. New Technique of Direct Intra-abdominal Pressure Measurement

    Directory of Open Access Journals (Sweden)

    Elena Risin

    2006-10-01

    Conclusion: Direct measurement of intra-abdominal pressure using 14-Fr PVC round drain is a newly described technique that is simple, fast and credible. Future investigation will be needed to confirm the reliability of this method during postoperative follow-up of intra-abdominal pressures in selected patients.

  20. Blood pressure measurement in obese patients: comparison between upper arm and forearm measurements.

    Science.gov (United States)

    Pierin, Angela M G; Alavarce, Débora C; Gusmão, Josiane L; Halpern, Alfredo; Mion, Décio

    2004-06-01

    It is well known that blood pressure measurement with a standard 12-13 cm wide cuff is erroneous for large arms. To compare arm blood pressure measurements with an appropriate cuff and forearm blood pressure measurements (BPM) with a standard cuff, and both measurements by the Photopletismography (Finapres) method. One hundred and twenty-nine obese patients were studied (body mass index=40+/-7 kg/m2). The patients had three arm BPM taken by an automatic oscillometric device using an appropriate cuff and three forearm BPM with a standard cuff in the sitting position after a five-minute rest. Data were analysed by the analysis of variance. The correction values were obtained by the linear regression test. Systolic and diastolic arm BPM with an appropriate cuff were significantly lower (pforearm BPM with a standard cuff. The measurements obtained by Finapres were significantly lower (pforearm systolic and diastolic blood pressures and upper arm diastolic blood pressure. The equation to correct BPM in forearm in obese patients with arm circumference between 32-44 cm was: systolic BPM=33.2+/-0.68 x systolic forearm BPM, and diastolic BPM=25.2+0.59 x forearm diastolic BPM. This study showed that forearm blood pressure measurement overestimates the values of arm blood pressure measurement. In addition, it is possible to correct forearm BPM with an equation.

  1. Dual-modality arterial pulse monitoring system for continuous blood pressure measurement.

    Science.gov (United States)

    Wen-Xuan Dai; Yuan-Ting Zhang; Jing Liu; Xiao-Rong Ding; Ni Zhao

    2016-08-01

    Accurate and ambulatory measurement of blood pressure (BP) is essential for efficient diagnosis, management and prevention of cardiovascular diseases (CVDs). However, traditional cuff-based BP measurement methods provide only intermittent BP readings and can cause discomfort with the occlusive cuff. Although pulse transit time (PTT) method is promising for cuffless and continuous BP measurement, its pervasive use is restricted by its limited accuracy and requirement of placing sensors on multiple body sites. To tackle these issues, we propose a novel dual-modality arterial pulse monitoring system for continuous blood pressure measurement, which simultaneously records the pressure and photoplethysmography (PPG) signals of radial artery. The obtained signals can be used to generate a pressure-volume curve, from which the elasticity index (EI) and viscosity index (VI) can be extracted. Experiments were carried out among 7 healthy subjects with their PPG, ECG, arterial pressure wave and reference BP collected to examine the effectiveness of the proposed indexes. The results of this study demonstrate that a linear regression model combining EI and VI has significantly higher BP tracking correlation coefficient as compared to the PTT method. This suggests that the proposed system and method can potentially be used for convenient and continuous blood pressure estimation with higher accuracy.

  2. Real-Time Pore Pressure Detection: Indicators and Improved Methods

    Directory of Open Access Journals (Sweden)

    Jincai Zhang

    2017-01-01

    Full Text Available High uncertainties may exist in the predrill pore pressure prediction in new prospects and deepwater subsalt wells; therefore, real-time pore pressure detection is highly needed to reduce drilling risks. The methods for pore pressure detection (the resistivity, sonic, and corrected d-exponent methods are improved using the depth-dependent normal compaction equations to adapt to the requirements of the real-time monitoring. A new method is proposed to calculate pore pressure from the connection gas or elevated background gas, which can be used for real-time pore pressure detection. The pore pressure detection using the logging-while-drilling, measurement-while-drilling, and mud logging data is also implemented and evaluated. Abnormal pore pressure indicators from the well logs, mud logs, and wellbore instability events are identified and analyzed to interpret abnormal pore pressures for guiding real-time drilling decisions. The principles for identifying abnormal pressure indicators are proposed to improve real-time pore pressure monitoring.

  3. On the extraction of pressure fields from PIV velocity measurements in turbines

    Science.gov (United States)

    Villegas, Arturo; Diez, Fancisco J.

    2012-11-01

    In this study, the pressure field for a water turbine is derived from particle image velocimetry (PIV) measurements. Measurements are performed in a recirculating water channel facility. The PIV measurements include calculating the tangential and axial forces applied to the turbine by solving the integral momentum equation around the airfoil. The results are compared with the forces obtained from the Blade Element Momentum theory (BEMT). Forces are calculated by using three different methods. In the first method, the pressure fields are obtained from PIV velocity fields by solving the Poisson equation. The boundary conditions are obtained from the Navier-Stokes momentum equations. In the second method, the pressure at the boundaries is determined by spatial integration of the pressure gradients along the boundaries. In the third method, applicable only to incompressible, inviscid, irrotational, and steady flow, the pressure is calculated using the Bernoulli equation. This approximated pressure is known to be accurate far from the airfoil and outside of the wake for steady flows. Additionally, the pressure is used to solve for the force from the integral momentum equation on the blade. From the three methods proposed to solve for pressure and forces from PIV measurements, the first one, which is solved by using the Poisson equation, provides the best match to the BEM theory calculations.

  4. Measurement of pressure pulsations in Francis turbines

    Energy Technology Data Exchange (ETDEWEB)

    Kobro, Einar

    2010-11-15

    The work presented in this thesis involves preparation and execution of measurements on Francis runners. The measurements were performed by means of onboard measuring equipment both in model runners and full-scale prototype runners. Also, analysis of the measured data, and the discussion of the results, is presented. The measurements resulted in large data sets. These data sets were used by the author to investigate the dynamic pressure and strain in the runners. The results of the analysis can be used as input in future turbine design. Andritz Hydro AG has used the data for verification of their numerical simulation tools. In connection with the refurbishment of Tokke power plant, two model runners were made available for onboard pressure measurements. To investigate the dynamic pressure in these runners, methods for integration of pressure transducers in the runner blades needed to be developed. After initial difficulties during the preparation, successful measurements were obtained from both model runners. At Tokke power plant, both the original and replacement runners were made accessible for onboard pressure and strain gauge measurements. On the original Kvaerner Brug AS runner, the test was prepared and performed by the author. This test failed, due to water intrusion in the logging chain. The second test was performed on the Andritz Hydro AG replacement runner. This test was prepared and performed by the author in close cooperation with Andritz Hydro AG, and the results were successful. The analysis results from both model and prototype runners show that the wake leaving the guide vanes is the most severe source of dynamic pressure in the runner. The draft tube vortex rope pulsation propagates upstream the runner, but does not appear as a significant frequency in the runner strain measurements. (Author)

  5. TREATMENT OF HYPERTENSION USING TELEMEDICAL HOME BLOOD PRESSURE MEASUREMENTS

    DEFF Research Database (Denmark)

    Hoffmann-Petersen, N; Lauritzen, T; Bech, J N

    2015-01-01

    OBJECTIVE: Telemonitoring of home blood pressure measurements (TBPM) is a new and promising supplement to diagnosis, control and treatment of hypertension. We wanted to compare the outcome of antihypertensive treatment based on TBPM and conventional monitoring of blood pressure. DESIGN AND METHOD...... of the measurements and subsequent communication by telephone or E-mail. In the control group, patients received usual care. Primary outcome was reduction in daytime ambulatory blood pressure measurements (ABPM) from baseline to 3 months' follow-up. RESULTS: In both groups, daytime ABPM decreased significantly....../181), p = 0.34. Blood pressure reduction in the TBPM group varied with the different practices. CONCLUSIONS: No further reduction in ABPM or number of patients reaching blood pressure targets was observed when electronic transmission of TBPM was applied in the treatment of hypertension by GPs. Thus...

  6. Systematic review of the use of Statistical Process Control methods to measure the success of pressure ulcer prevention.

    Science.gov (United States)

    Clark, Michael; Young, Trudie; Fallon, Maureen

    2018-06-01

    Successful prevention of pressure ulcers is the end product of a complex series of care processes including, but not limited to, the assessment of vulnerability to pressure damage; skin assessment and care; nutritional support; repositioning; and the use of beds, mattresses, and cushions to manage mechanical loads on the skin and soft tissues. The purpose of this review was to examine where and how Statistical Process Control (SPC) measures have been used to assess the success of quality improvement initiatives intended to improve pressure ulcer prevention. A search of 7 electronic bibliographic databases was performed on May 17th, 2017, for studies that met the inclusion criteria. SPC methods have been reported in 9 publications since 2010 to interpret changes in the incidence of pressure ulcers over time. While these methods offer rapid interpretation of changes in incidence than is gained from a comparison of 2 arbitrarily selected time points pre- and post-implementation of change, more work is required to ensure that the clinical and scientific communities adopt the most appropriate SPC methods. © 2018 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  7. Intelligent pressure measurement in multiple sensor arrays

    International Nuclear Information System (INIS)

    Matthews, C.A.

    1995-01-01

    Pressure data acquisition has typically consisted of a group of sensors scanned by an electronic or mechanical multiplexer. The data accuracy was dependent upon the temperature stability of the sensors. This paper describes a new method of pressure measurement that combines individual temperature compensated pressure sensors, a microprocessor, and an A/D converter in one module. Each sensor has its own temperature characteristics stored in a look-up table to minimize sensor thermal errors. The result is an intelligent pressure module that can output temperature compensated engineering units over an Ethernet interface. Calibration intervals can be dramatically extended depending upon system accuracy requirements and calibration techniques used

  8. Pressure dependence of thermal conductivity and specific heat in CeRh2Si2 measured by an extended thermal relaxation method

    Science.gov (United States)

    Nishigori, Shijo; Seida, Osamu

    2018-05-01

    We have developed a new technique for measuring thermal conductivity and specific heat under pressure by improving a thermal relaxation method. In this technique, a cylindrical sample with a small disc heater is embedded in the pressure-transmitting medium, then temperature variations of the sample and heater were directly measured by thermocouples during a heating and cooling process. Thermal conductivity and specific heat are estimated by comparing the experimental data with temperature variations simulated by a finite element method. The obtained thermal conductivity and specific heat of the test sample CeRh2Si2 exhibit a small enhancement and a clear peak arising from antiferromagnetic transition, respectively. The observation of these typical behaviors for magnetic compounds indicate that the technique is valid for the study on thermal properties under pressure.

  9. Techniques of Force and Pressure Measurement in the Small Joints of the Wrist.

    Science.gov (United States)

    Schreck, Michael J; Kelly, Meghan; Canham, Colin D; Elfar, John C

    2018-01-01

    The alteration of forces across joints can result in instability and subsequent disability. Previous methods of force measurements such as pressure-sensitive films, load cells, and pressure-sensing transducers have been utilized to estimate biomechanical forces across joints and more recent studies have utilized a nondestructive method that allows for assessment of joint forces under ligamentous restraints. A comprehensive review of the literature was performed to explore the numerous biomechanical methods utilized to estimate intra-articular forces. Methods of biomechanical force measurements in joints are reviewed. Methods such as pressure-sensitive films, load cells, and pressure-sensing transducers require significant intra-articular disruption and thus may result in inaccurate measurements, especially in small joints such as those within the wrist and hand. Non-destructive methods of joint force measurements either utilizing distraction-based joint reaction force methods or finite element analysis may offer a more accurate assessment; however, given their recent inception, further studies are needed to improve and validate their use.

  10. Hepatic venous pressure gradients measured by duplex ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Tasu, J.-P.; Rocher, L.; Peletier, G.; Kuoch, V.; Kulh, E.; Miquel, A.; Buffet, C.; Biery, M

    2002-08-01

    AIMS: The hepatic venous pressure gradient is a major prognostic factor in portal hypertension but its measurement is complex and requires invasive angiography. This study investigated the relationship between the hepatic venous pressure gradient and a number of Doppler measurements, including the arterial acceleration index. METHOD: We measured the hepatic venous pressure gradient in 50 fasting patients at hepatic venography. Immediately afterwards, a duplex sonographic examination of the liver was performed at which multiple measurements and indices of the venous and arterial hepatic vasculature were made. RESULTS: Hepatic arterial acceleration was correlated directly with the hepatic venous pressure gradient (r = 0.83, P < 0.0001) and with the Child-Pugh score (r = 0.63, P < 0.0001). An acceleration index cut-off value of 1 m.s{sup -2} provided a positive predictive value of 95%, a sensitivity of 65% and a specificity of 95% for detecting patients with severe portal hypertension (hepatic venous pressure gradient > 12 mmHg). A correlation between the hepatic venous pressure gradient and the congestion index of the portal vein velocity (r = 0.45,P = 0.01) and portal vein velocity (r = 0.40,P = 0.044), was also noted. CONCLUSION: Measuring the hepatic arterial acceleration index may help in the non-invasive evaluation of portal hypertension. Tasu, J.-P. et al. (2002)

  11. Pressure measurement using thermal properties of materials

    International Nuclear Information System (INIS)

    Cruz Pessoa, Jose Dalton; Calbo, Adonai Gimenes

    2004-01-01

    This work presents a design and two methods, one isothermal and one isovolumetric, for pressure measurements based on the compressibility coefficient (κ) and thermal expansibility (α) of the fluid under test. The setup and relevant construction details are described. To demonstrate the applicability of the isovolumetric measurement method, the setup was calibrated with respect to a Bourdon-type manometer; the other isothermic method was analyzed to determine construction details that could realize resolution requirements. The authors determined the effect of ambient temperature on device operation and the time response of the isovolumetric method. The device can be used to estimate the compressibility of a fluid and, in addition, could become an alternative for direct plant cell turgor measurement

  12. Measurement of cardiac output in children by pressure-recording analytical method.

    Science.gov (United States)

    Urbano, Javier; López, Jorge; González, Rafael; Solana, María José; Fernández, Sarah N; Bellón, José M; López-Herce, Jesús

    2015-02-01

    We evaluated two pressure-recording analytical method (PRAM) software versions (v.1 and v.2) to measure cardiac index (CI) in hemodynamically stable critically ill children and investigate factors that influence PRAM values. The working hypothesis was that PRAM CI measurements would stay within normal limits in hemodynamically stable patients. Ninety-five CI PRAM measurements were analyzed in 47 patients aged 1-168 months. Mean CI was 4.1 ± 1.4 L/min/m(2) (range 2.0-7.0). CI was outside limits defined as normal (3-5 L/min/m(2)) in 53.7% of measurements (47.8% with software v.1 and 69.2% with software v.2, p = 0.062). Moreover, 14.7% of measurements were below 2.5 L/min/m(2), and 13.6% were above 6 L/min/m(2). CI was significantly lower in patients with a clearly visible dicrotic notch than in those without (3.7 vs. 4.6 L/min/m(2), p = 0.004) and in children with a radial arterial catheter (3.5 L/min/m(2)) than in those with a brachial (4.4 L/min/m(2), p = 0.021) or femoral catheter (4.7 L/min/m(2), p = 0.005). By contrast, CI was significantly higher in children under 12 months (4.2 vs. 3.6 L/min/m(2), p = 0.034) and weighing under 10 kg (4.2 vs. 3.6 L/min/m(2), p = 0.026). No significant differences were observed between cardiac surgery patients and the rest of children. A high percentage of CI measurements registered by PRAM were outside normal limits in hemodynamically stable, critically ill children. CI measured by PRAM may be influenced by the age, weight, location of catheter, and presence of a dicrotic notch.

  13. Pressure Measurement Techniques for Abdominal Hypertension: Conclusions from an Experimental Model.

    Science.gov (United States)

    Chopra, Sascha Santosh; Wolf, Stefan; Rohde, Veit; Freimann, Florian Baptist

    2015-01-01

    Introduction. Intra-abdominal pressure (IAP) measurement is an indispensable tool for the diagnosis of abdominal hypertension. Different techniques have been described in the literature and applied in the clinical setting. Methods. A porcine model was created to simulate an abdominal compartment syndrome ranging from baseline IAP to 30 mmHg. Three different measurement techniques were applied, comprising telemetric piezoresistive probes at two different sites (epigastric and pelvic) for direct pressure measurement and intragastric and intravesical probes for indirect measurement. Results. The mean difference between the invasive IAP measurements using telemetric pressure probes and the IVP measurements was -0.58 mmHg. The bias between the invasive IAP measurements and the IGP measurements was 3.8 mmHg. Compared to the realistic results of the intraperitoneal and intravesical measurements, the intragastric data showed a strong tendency towards decreased values. The hydrostatic character of the IAP was eliminated at high-pressure levels. Conclusion. We conclude that intragastric pressure measurement is potentially hazardous and might lead to inaccurately low intra-abdominal pressure values. This may result in missed diagnosis of elevated abdominal pressure or even ACS. The intravesical measurements showed the most accurate values during baseline pressure and both high-pressure plateaus.

  14. An optical method for measuring exhaust gas pressure from an internal combustion engine at high speed.

    Science.gov (United States)

    Leach, Felix C P; Davy, Martin H; Siskin, Dmitrij; Pechstedt, Ralf; Richardson, David

    2017-12-01

    Measurement of exhaust gas pressure at high speed in an engine is important for engine efficiency, computational fluid dynamics analysis, and turbocharger matching. Currently used piezoresistive sensors are bulky, require cooling, and have limited lifetimes. A new sensor system uses an interferometric technique to measure pressure by measuring the size of an optical cavity, which varies with pressure due to movement of a diaphragm. This pressure measurement system has been used in gas turbine engines where the temperatures and pressures have no significant transients but has never been applied to an internal combustion engine before, an environment where both temperature and pressure can change rapidly. This sensor has been compared with a piezoresistive sensor representing the current state-of-the-art at three engine operating points corresponding to both light load and full load. The results show that the new sensor can match the measurements from the piezoresistive sensor except when there are fast temperature swings, so the latter part of the pressure during exhaust blowdown is only tracked with an offset. A modified sensor designed to compensate for these temperature effects is also tested. The new sensor has shown significant potential as a compact, durable sensor, which does not require external cooling.

  15. An optical method for measuring exhaust gas pressure from an internal combustion engine at high speed

    Science.gov (United States)

    Leach, Felix C. P.; Davy, Martin H.; Siskin, Dmitrij; Pechstedt, Ralf; Richardson, David

    2017-12-01

    Measurement of exhaust gas pressure at high speed in an engine is important for engine efficiency, computational fluid dynamics analysis, and turbocharger matching. Currently used piezoresistive sensors are bulky, require cooling, and have limited lifetimes. A new sensor system uses an interferometric technique to measure pressure by measuring the size of an optical cavity, which varies with pressure due to movement of a diaphragm. This pressure measurement system has been used in gas turbine engines where the temperatures and pressures have no significant transients but has never been applied to an internal combustion engine before, an environment where both temperature and pressure can change rapidly. This sensor has been compared with a piezoresistive sensor representing the current state-of-the-art at three engine operating points corresponding to both light load and full load. The results show that the new sensor can match the measurements from the piezoresistive sensor except when there are fast temperature swings, so the latter part of the pressure during exhaust blowdown is only tracked with an offset. A modified sensor designed to compensate for these temperature effects is also tested. The new sensor has shown significant potential as a compact, durable sensor, which does not require external cooling.

  16. Research on Water Velocity Measurement of Reservoir Based on Pressure Sensor

    Directory of Open Access Journals (Sweden)

    Xiaoqiang Zhao

    2014-11-01

    Full Text Available To address the problem that pressure sensor can only measure the liquid level in reservoir, we designed a current velocity measurement system of reservoir based on pressure sensor, analyzed the error of current velocity measurement system, and proposed the error processing method and corresponding program. Several tests and experimental results show that in this measurement system, the liquid level measurement standard deviation is no more than 0.01 cm, and the current velocity measurement standard deviation is no more than 0.35 mL/s, which proves that the pressure sensor can measure both liquid level and current velocity synchronously.

  17. A laboratory measurement method for pressure sensitive adhesives in agglomeration deinking of mixed office waste paper: The high-low scanning contrast method

    OpenAIRE

    Guolin Tong; Shuang Sun; Cuixia Wang; Kecheng Fu; Yungchang F. Chin

    2012-01-01

    A simple measurement method for pressure sensitive adhesives (PSA) in an agglomeration deinking system of mixed office waste paper was studied. This method was based on the different scanning performance of ink and PSA specks in hot-pressed and oven-dried handsheets with the change of contrast values that had been selected and set in the image analysis software. The numbers of ink specks per square meter (NPM) were well recognized at both low and high contrast values and exhibited a very good...

  18. LOFT fuel rod pressure measurement

    International Nuclear Information System (INIS)

    Billeter, T.R.

    1979-01-01

    Pressure sensors selected for measuring fuel rod pressure within the LOFT reactor exhibited stable, repeatable operating characteristics during calibrations at temperatures up to 800 0 F and pressures to 2500 psig. All sensors have a nominal sensitivity of .5 millivolts per psi, decreasing monotonically with temperature. Output signal increases linearly with increasing pressure up to 2000 psig. For imposed slow and rapid temperature variations and for pressure applied during these tests, the sensor indicates a pressure at variance with the actual value by up to 15% of reading. However, the imposed temperature rates of change often exceeded the value of -10 0 F/sec. specified for LOFT. The series of tests in an autoclave permit creation of an environment most closely resembling sensor operating conditions within LOFT. For multiple blowdowns and for longtime durations the sensor continued to provide pressure-related output signals. For temperature rates up to -87 0 F/sec, the indicated pressure measurement error remained less than 13% of reading. Adverse effects caused by heating the 1/16 inch O.D. signal cable to 800 0 F contributed only insignificantly to the noted pressure measurement error

  19. Quantitative Assessment of Blood Pressure Measurement Accuracy and Variability from Visual Auscultation Method by Observers without Receiving Medical Training

    Science.gov (United States)

    Feng, Yong; Chen, Aiqing

    2017-01-01

    This study aimed to quantify blood pressure (BP) measurement accuracy and variability with different techniques. Thirty video clips of BP recordings from the BHS training database were converted to Korotkoff sound waveforms. Ten observers without receiving medical training were asked to determine BPs using (a) traditional manual auscultatory method and (b) visual auscultation method by visualizing the Korotkoff sound waveform, which was repeated three times on different days. The measurement error was calculated against the reference answers, and the measurement variability was calculated from the SD of the three repeats. Statistical analysis showed that, in comparison with the auscultatory method, visual method significantly reduced overall variability from 2.2 to 1.1 mmHg for SBP and from 1.9 to 0.9 mmHg for DBP (both p auscultation methods). In conclusion, the visual auscultation method had the ability to achieve an acceptable degree of BP measurement accuracy, with smaller variability in comparison with the traditional auscultatory method. PMID:29423405

  20. A viscosity measurement during the high pressure phase transition in triolein

    International Nuclear Information System (INIS)

    Siegoczynski, R M; Rostocki, A J; Kielczynski, P; Szalewski, M

    2008-01-01

    The high-pressure properties of triolein, a subject of extensive research at the Faculty of Physics of Warsaw University of Technology (WUT) have been enhanced by the results of viscosity measurement within the pressure range up to 0.8 GPa. For the measurement the authors have adopted a new ultrasonic method based on Bleustein-Gulyaev waves, successfully developed earlier for the low pressures in the Section of Acoustoelectronics of the Institute of Fundamental Technological Research. The measurements have shown: 1. Exponential rise of viscosity with pressure up to 0.5 GPa. 2. Extraordinary increment of viscosity at constant pressure during phase transition. 3. Further exponential rise of viscosity with pressure of the high-pressure phase of triolein. 4. The pressure exponents of the viscosity of both phases were different (the high-pressure phase had much smaller exponent). 5. The decomposition of the high pressure phase due to the slow decompression have shown very large hysteresis of viscosity on pressure dependence

  1. Measurements of Pressure of Extracorporeal Shock Wave Lithotripter Using Pressure-Sensitive Papers

    Science.gov (United States)

    Inose, Naoto; Ide, Masao

    1993-05-01

    This paper describes measurements of pressures at the focal region of the extracorporeal shock wave lithotripter (ESWL) using pressure-sensitive papers. At the focal region of ESWL, ordinary hydrophones are quickly damaged, because of very high pressures. Recently, measurements of pressure at the focal region of ESWL using pressure-sensitive paper have been advised. Therefore, we have studied the effectiveness of pressure-sensitive papers in the measurement of high acoustic pressures at the focal region of ESWL.

  2. A Modern Method to Monitor Office Blood Pressure

    Directory of Open Access Journals (Sweden)

    Emiliya Khazan

    2017-10-01

    Full Text Available The diagnosis and management of hypertension relies on accurate and precise blood pressure (BP measurements and monitoring techniques. Variability in traditional office based BP readings can contribute to misclassification and potential misdiagnosis of hypertension, leading to inappropriate treatment and possibly avoidable adverse drug events. Both home blood pressure monitoring (HBPM and 24-hour ambulatory blood pressure monitoring (ABPM can improve characterization of BP status over traditional office values and can predict cardiovascular morbidity and mortality risk; however, they are limited by availability and/or practical use in many situations. Available in-office blood pressure measuring methods include manual auscultation, automated oscillometric, and automated office blood pressure (AOBP devices. A strong correlation exists between AOBP and awake ABPM measurements and has been linked to better prediction of end-organ damage and white coat response compared to standard office BP methods. While AOBP does not provide nocturnal BP readings, it can be utilized in several outpatient settings, and has the capability to decrease utilization of ABPM, white coat effect, and improve optimization of cardiovascular assessment, evaluation, and therapeutic assessment in clinical practice. Hypertension affects over 80 million adults in the United States (US and is a major risk factor for cardiovascular morbidity and mortality [1]. The condition’s ubiquitous nature and broad impact potentially makes understanding the diagnosis and treatment of hypertension key elements of managing cardiovascular risk. Though much attention is paid to the treatment of hypertension, from 2009 to 2012, 45.9% of US patients with hypertension were uncontrolled [1]. Appreciating the aspects of proper assessment of blood pressure is crucial and creates the foundation for approaching hypertension management. Until recently, hypertension was defined as an appropriately

  3. Inferring Pre-shock Acoustic Field From Post-shock Pitot Pressure Measurement

    Science.gov (United States)

    Wang, Jian-Xun; Zhang, Chao; Duan, Lian; Xiao, Heng; Virginia Tech Team; Missouri Univ of Sci; Tech Team

    2017-11-01

    Linear interaction analysis (LIA) and iterative ensemble Kalman method are used to convert post-shock Pitot pressure fluctuations to static pressure fluctuations in front of the shock. The LIA is used as the forward model for the transfer function associated with a homogeneous field of acoustic waves passing through a nominally normal shock wave. The iterative ensemble Kalman method is then employed to infer the spectrum of upstream acoustic waves based on the post-shock Pitot pressure measured at a single point. Several test cases with synthetic and real measurement data are used to demonstrate the merits of the proposed inference scheme. The study provides the basis for measuring tunnel freestream noise with intrusive probes in noisy supersonic wind tunnels.

  4. [Evaluation of accuracy of measuring intraocular pressure by handheld non-contact applanation tonometer].

    Science.gov (United States)

    Chen, X; Peng, D; Zhou, W; Zhong, Y

    1995-06-01

    To evaluate the accuracy of measuring intraocular pressure by handheld non-contact applanation tonometer. 58 patients' (113 eyes) intraocular pressure were measured by Keeler, non-contact tonometer and R 900 Goldmann applanation tonometer and the results of measurement of intraocular pressure by the two kinds of tonometers were compared. The mean intraocular pressure measured by non-contact is 16.31 +/- 5.59 mmHg and 17.49 +/- 6.13 mmHg (1 mmHg = 0.1333 kPa) by Goldmann applanation tonometer, respectively. There was no statistical significance to be found (P > 0.05) between the two methods. By linear correlation and regression analysis, a positive correlation was found between the two methods (r = 0.8942, b = 0.8154). The handheld non-contact tonometer has the same accuracy and reliability of measurement of intraocular pressure comparing with Goldmann applanation tonometer, and it can be used in glaucoma clinic and screening.

  5. Differential Intracochlear Sound Pressure Measurements in Human Temporal Bones with an Off-the-Shelf Sensor

    Directory of Open Access Journals (Sweden)

    Martin Grossöhmichen

    2016-01-01

    Full Text Available The standard method to determine the output level of acoustic and mechanical stimulation to the inner ear is measurement of vibration response of the stapes in human cadaveric temporal bones (TBs by laser Doppler vibrometry. However, this method is reliable only if the intact ossicular chain is stimulated. For other stimulation modes an alternative method is needed. The differential intracochlear sound pressure between scala vestibuli (SV and scala tympani (ST is assumed to correlate with excitation. Using a custom-made pressure sensor it has been successfully measured and used to determine the output level of acoustic and mechanical stimulation. To make this method generally accessible, an off-the-shelf pressure sensor (Samba Preclin 420 LP, Samba Sensors was tested here for intracochlear sound pressure measurements. During acoustic stimulation, intracochlear sound pressures were simultaneously measurable in SV and ST between 0.1 and 8 kHz with sufficient signal-to-noise ratios with this sensor. The pressure differences were comparable to results obtained with custom-made sensors. Our results demonstrated that the pressure sensor Samba Preclin 420 LP is usable for measurements of intracochlear sound pressures in SV and ST and for the determination of differential intracochlear sound pressures.

  6. Assessment of sub-division of plantar pressure measurement in children.

    Science.gov (United States)

    Stebbins, J A; Harrington, M E; Giacomozzi, C; Thompson, N; Zavatsky, A; Theologis, T N

    2005-12-01

    Methods for the measurement of plantar pressure are poorly defined particularly when describing sub-sections of the plantar surface of the foot in the presence of deformity. The aim of this study was to assess foot pressure measurement in healthy children, using an automatic technique of sub-area definition that has the potential for objective evaluation of treatment of foot deformity. Twelve healthy children were examined on three occasions. Plantar pressure data were collected and time synchronised with force plate and stereophotogrammetric data. The footprint was divided into five sub-sections by using the position of the markers on the foot at mid-stance projected onto the pressure footprint. Repeatability for peak pressure and peak force was assessed. Automatic sub-area definition based on marker placement was found to be reliable in healthy children. A comparison of results revealed that peak vertical force was a more consistent measure than peak pressure for each of the five sub-areas. This suggests that force may be a more appropriate measurement for outcome studies.

  7. Dynamic calibration of piezoelectric transducers for ballistic high-pressure measurement

    Directory of Open Access Journals (Sweden)

    Elkarous Lamine

    2016-01-01

    Full Text Available The development of a dynamic calibration standard for high-amplitude pressure piezoelectric transducers implies the implementation of a system which can provide reference pressure values with known characteristics and uncertainty. The reference pressure must be issued by a sensor, as a part of a measuring chain, with a guaranteed traceability to an international standard. However, this operation has not been completely addressed yet until today and is still calling further investigations. In this paper, we introduce an experimental study carried out in order to contribute to current efforts for the establishment of a reference dynamic calibration method. A suitable practical calibration method based on the calculation of the reference pressure by measurement of the displacement of the piston in contact with an oil-filled cylindrical chamber is presented. This measurement was achieved thanks to a high speed camera and an accelerometer. Both measurements are then compared. In the first way, pressure was generated by impacting the piston with a free falling weight and, in the second way, with strikers of known weights and accelerated to the impact velocities with an air gun. The aim of the experimental setup is to work out a system which may generate known hydraulic pressure pulses with high-accuracy and known uncertainty. Moreover, physical models were also introduced to consolidate the experimental study. The change of striker’s velocities and masses allows tuning the reference pressure pulses with different shapes and, therefore, permits to sweep a wide range of magnitudes and frequencies.

  8. Automatic noninvasive measurement of systolic blood pressure using photoplethysmography

    Directory of Open Access Journals (Sweden)

    Glik Zehava

    2009-10-01

    Full Text Available Abstract Background Automatic measurement of arterial blood pressure is important, but the available commercial automatic blood pressure meters, mostly based on oscillometry, are of low accuracy. Methods In this study, we present a cuff-based technique for automatic measurement of systolic blood pressure, based on photoplethysmographic signals measured simultaneously in fingers of both hands. After inflating the pressure cuff to a level above systolic blood pressure in a relatively slow rate, it is slowly deflated. The cuff pressure for which the photoplethysmographic signal reappeared during the deflation of the pressure-cuff was taken as the systolic blood pressure. The algorithm for the detection of the photoplethysmographic signal involves: (1 determination of the time-segments in which the photoplethysmographic signal distal to the cuff is expected to appear, utilizing the photoplethysmographic signal in the free hand, and (2 discrimination between random fluctuations and photoplethysmographic pattern. The detected pulses in the time-segments were identified as photoplethysmographic pulses if they met two criteria, based on the pulse waveform and on the correlation between the signal in each segment and the signal in the two neighboring segments. Results Comparison of the photoplethysmographic-based automatic technique to sphygmomanometry, the reference standard, shows that the standard deviation of their differences was 3.7 mmHg. For subjects with systolic blood pressure above 130 mmHg the standard deviation was even lower, 2.9 mmHg. These values are much lower than the 8 mmHg value imposed by AAMI standard for automatic blood pressure meters. Conclusion The photoplethysmographic-based technique for automatic measurement of systolic blood pressure, and the algorithm which was presented in this study, seems to be accurate.

  9. Correction of static pressure on a research aircraft in accelerated flight using differential pressure measurements

    Directory of Open Access Journals (Sweden)

    A. R. Rodi

    2012-11-01

    Full Text Available A method is described that estimates the error in the static pressure measurement on an aircraft from differential pressure measurements on the hemispherical surface of a Rosemount model 858AJ air velocity probe mounted on a boom ahead of the aircraft. The theoretical predictions for how the pressure should vary over the surface of the hemisphere, involving an unknown sensitivity parameter, leads to a set of equations that can be solved for the unknowns – angle of attack, angle of sideslip, dynamic pressure and the error in static pressure – if the sensitivity factor can be determined. The sensitivity factor was determined on the University of Wyoming King Air research aircraft by comparisons with the error measured with a carefully designed sonde towed on connecting tubing behind the aircraft – a trailing cone – and the result was shown to have a precision of about ±10 Pa over a wide range of conditions, including various altitudes, power settings, and gear and flap extensions. Under accelerated flight conditions, geometric altitude data from a combined Global Navigation Satellite System (GNSS and inertial measurement unit (IMU system are used to estimate acceleration effects on the error, and the algorithm is shown to predict corrections to a precision of better than ±20 Pa under those conditions. Some limiting factors affecting the precision of static pressure measurement on a research aircraft are discussed.

  10. The position of the arm during blood pressure measurement in sitting position.

    NARCIS (Netherlands)

    Adiyaman, A.; Verhoeff, R.; Lenders, J.W.M.; Deinum, J.; Thien, Th.

    2006-01-01

    OBJECTIVE: Determining the influence of the position of the arm on blood pressure measurement in the sitting position. METHODS: Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in

  11. A novel experimental mechanics method for measuring the light pressure acting on a solar sail membrane

    Science.gov (United States)

    Shi, Aiming; Jiang, Li; Dowell, Earl H.; Qin, Zhixuan

    2017-02-01

    Solar sail is a high potential `sailing craft' for interstellar exploration. The area of the first flight solar sail demonstrator named "IKAROS" is 200 square meters. Future interplanetary missions will require solar sails at least on the order of 10000 square meters (or larger). Due to the limitation of ground facilities, the size of experimental sample should not be large. Furthermore the ground experiments have to be conducted in gravitational field, so the gravity effect must be considered in a ground test. To obtain insight into the solar sail membrane dynamics, a key membrane flutter (or limit cycle oscillations) experiment with light forces acting on it must be done. But one big challenge is calibrating such a tiny light force by as a function of the input power. In this paper, a gravity-based measuring method for light pressure acting on membrane is presented. To explain the experimental principle, an ideal example of a laser beam with expanders and a metal film is studied. Based on calculations, this experimental mechanics method for calibrating light pressure with an accuracy of 0.01 micro-Newton may be realized by making the light force balance the gravity force on the metal films. This gravity-based measuring method could not only be applied to study the dynamics characteristics of solar sail membrane structure with different light forces, but could also be used to determine more accurate light forces/loads acting on solar sail films and hence to enhance the determination of the mechanical properties of the solar sail membrane structure.

  12. Iterative Boltzmann plot method for temperature and pressure determination in a xenon high pressure discharge lamp

    Energy Technology Data Exchange (ETDEWEB)

    Zalach, J.; Franke, St. [INP Greifswald, Felix-Hausdorff-Str. 2, 17489 Greifswald (Germany)

    2013-01-28

    The Boltzmann plot method allows to calculate plasma temperatures and pressures if absolutely calibrated emission coefficients of spectral lines are available. However, xenon arcs are not very well suited to be analyzed this way, as there are only a limited number of lines with atomic data available. These lines have high excitation energies in a small interval between 9.8 and 11.5 eV. Uncertainties in the experimental method and in the atomic data further limit the accuracy of the evaluation procedure. This may result in implausible values of temperature and pressure with inadmissible uncertainty. To omit these shortcomings, an iterative scheme is proposed that is making use of additional information about the xenon fill pressure. This method is proved to be robust against noisy data and significantly reduces the uncertainties. Intentionally distorted synthetic data are used to illustrate the performance of the method, and measurements performed on a laboratory xenon high pressure discharge lamp are analyzed resulting in reasonable temperatures and pressures with significantly reduced uncertainties.

  13. Measurements of the Exerted Pressure by Pelvic Circumferential Compression Devices

    Science.gov (United States)

    Knops, Simon P; van Riel, Marcel P.J.M; Goossens, Richard H.M; van Lieshout, Esther M.M; Patka, Peter; Schipper, Inger B

    2010-01-01

    Background: Data on the efficacy and safety of non-invasive Pelvic Circumferential Compression Devices (PCCDs) is limited. Tissue damage may occur if a continuous pressure on the skin exceeding 9.3 kPa is sustained for more than two or three hours. The aim of this study was to gain insight into the pressure build-up at the interface, by measuring the PCCD-induced pressure when applying pulling forces to three different PCCDs (Pelvic Binder® , SAM-Sling ® and T-POD® ) in a simplified model. Methods: The resulting exerted pressures were measured at four ‘anatomical’ locations (right, left, posterior and anterior) in a model using a pressure measurement system consisting of pressure cuffs. Results: The exerted pressure varied substantially between the locations as well as between the PCCDs. Maximum pressures ranged from 18.9-23.3 kPa and from 19.2-27.5 kPa at the right location and left location, respectively. Pressures at the posterior location stayed below 18 kPa. At the anterior location pressures varied markedly between the different PCCDs. Conclusion: The circumferential compression by the different PCCDs showed high pressures measured at the four locations using a simplified model. Difference in design and functional characteristics of the PCCDs resulted in different pressure build-up at the four locations. When following the manufacturer’s instructions, the exerted pressure of all three PCCDs tested exceeded the tissue damaging level (9.3 kPa). In case of prolonged use in a clinical situation this might put patients at risk for developing tissue damage. PMID:20361001

  14. Unsteady pressures on a blunt trailing edge measured with an embedded pressure scanner

    Science.gov (United States)

    Naughton, Jonathan; Nikoueeyan, Pourya; Hind, Michael; Strike, John; Dahland, Matz; Keeter, Steven

    2017-11-01

    Development of direct-mount pressure scanners can decrease the pneumatic tubing length required to connect the measurement ports to the scanner manifold resulting in improved dynamic range for unsteady pressure measurements. In this work, the performance of a direct-mount pressure scanner for time-resolved pressure measurement is demonstrated in a well-established flow; the pressure fluctuations near the base of flat plate is considered. The additive manufactured model is instrumented with a pressure scanner and flush-mounted high-speed pressure transducers. The configuration of the ports on the model allows for side-by-side comparison of the pressures measured via embedded pneumatic tubing routed to a pressure scanner with that measured by high-speed transducers. Prior to testing, the dynamic response of each embedded pressure port is dynamically calibrated via an in-situ calibration technique. Pressure data is then acquired for fixed angle-of-attack and different dynamic pitching conditions. The dynamic range of the measurements acquired via direct-mount scanner will be compared to those acquired by the high speed transducers for both static and dynamic pitching configurations. The uncertainties associated with Weiner deconvolution are also quantified for the measurements.

  15. Endotracheal tube cuff pressure monitoring during neurosurgery - Manual vs. automatic method

    Directory of Open Access Journals (Sweden)

    Mukul Kumar Jain

    2011-01-01

    Full Text Available Background: Inflation and assessment of the endotracheal tube cuff pressure is often not appreciated as a critical aspect of endotracheal intubation. Appropriate endotracheal tube cuff pressure, endotracheal intubation seals the airway to prevent aspiration and provides for positive-pressure ventilation without air leak. Materials and Methods: Correlations between manual methods of assessing the pressure by an experienced anesthesiologists and assessment with maintenance of the pressure within the normal range by the automated pressure controller device were studied in 100 patients divided into two groups. In Group M, endotracheal tube cuff was inflated manually by a trained anesthesiologist and checked for its pressure hourly by cuff pressure monitor till the end of surgery. In Group C, endotracheal tube cuff was inflated by automated cuff pressure controller and pressure was maintained at 25-cm H 2 O throughout the surgeries. Repeated measure ANOVA was applied. Results: Repeated measure ANOVA results showed that average of endotracheal tube cuff pressure of 50 patients taken at seven different points is significantly different (F-value: 171.102, P-value: 0.000. Bonferroni correction test shows that average of endotracheal tube cuff pressure in all six groups are significantly different from constant group (P = 0.000. No case of laryngomalacia, tracheomalacia, tracheal stenosis, tracheoesophageal fistula or aspiration pneumonitis was observed. Conclusions: Endotracheal tube cuff pressure was significantly high when endotracheal tube cuff was inflated manually. The known complications of high endotracheal tube cuff pressure can be avoided if the cuff pressure controller device is used and manual methods cannot be relied upon for keeping the pressure within the recommended levels.

  16. Gingival blood flow under total combs by functional pressure evaluated with laser-Doppler flowmetry, a non-invasive method of blood flow measurement

    International Nuclear Information System (INIS)

    Hengl, St.

    1996-09-01

    Gingival blood flow under total-combs by functional pressure evaluated with Laser-Doppler Flowmetry, a non-invasive method of blood flow measurement. Microcirculation of gum's capillary system can be measured non-invasive by Laser-Doppler-Flowmetry (LDF). Circulation, defined by the number of floating erythrocytes per unit of time, is measured by a fibro-optical Laser-Doppler-Flowmetry. The task was to examine, if there is any change of gum's circulation during strain and relief. Circulation on defined measurepoints, divided on the four quadrants, was determined among maximal strain and subsequent relief, on one probationer (complete denture bearer). Before every measure session systemic pressure was taken. LDF-value was taken on top of jaw-comb, in doing so, to get reproducible result and a satisfying fixation of the probe, there was made an artificial limb of the upper and lower comb. In the upper comb a dynamometer-box, which determined minimal and maximal comb pressure, was integrated. The received results of the LDF-measurement, expressed as perfusion units (PU) were lower under applied pressure than by pressure points more distant. Hyperemia, resulting during relief, seemed the more intense, the less perfusion was before. This new, non-invasive kind of circulation measurement seems to be quite predestined to be used for gingival diagnostic under artificial limb in the future. (author)

  17. Combination of phlebography and sanguinous measurement of venous blood pressure

    International Nuclear Information System (INIS)

    Weber, J.

    1988-01-01

    Phlebographic visualisation offers the highest spatial resolution of all imaging methods both in respect of veins of the leg and pelvis and of the abdomen. Phlebography offers optimal conditions for assessing morphological changes at the veins and in their direct neighbourhood. No quantitative information is available via phlebography if haemodynamics are disturbed; qualitative information is yielded merely to a restricted extent (by assessing flow velocity and collaterals). Direct sanguinous measurement of venous blood pressure is particularly suitable for the quantitative and qualitative assessment of disturbed haemodynamic conditions; in this respect it stands out among the function tests based on the employment of apparatures. If it is combined with phlebography, it is possible not only to optimise the diagnostic yield in the hands of one investigator, but also to reduce the invasiveness of both methods to one single puncture, since the puncture needle is at the same time also an instrument to measure the pressure. The article points out the possibilities and limitations of combining a) ascending phlebography of the leg and pelvis with peripheral venous pressure measurement (phlebodynamometry) and b) visualisation of the veins of the pelvis and vena cava inferior with central sanguinous venous pressure measurement (CP). Indicatious and technical execution are described. (orig.) [de

  18. Photoluminescence excitation measurements using pressure-tuned laser diodes

    Science.gov (United States)

    Bercha, Artem; Ivonyak, Yurii; Medryk, Radosław; Trzeciakowski, Witold A.; Dybała, Filip; Piechal, Bernard

    2015-06-01

    Pressure-tuned laser diodes in external cavity were used as tunable sources for photoluminescence excitation (PLE) spectroscopy. The method was demonstrated in the 720 nm-1070 nm spectral range using a few commercial laser diodes. The samples for PLE measurements were quantum-well structures grown on GaAs and on InP. The method is superior to standard PLE measurements using titanium sapphire laser because it can be extended to any spectral range where anti-reflection coated laser diodes are available.

  19. Photoluminescence excitation measurements using pressure-tuned laser diodes

    International Nuclear Information System (INIS)

    Bercha, Artem; Ivonyak, Yurii; Mędryk, Radosław; Trzeciakowski, Witold A.; Dybała, Filip; Piechal, Bernard

    2015-01-01

    Pressure-tuned laser diodes in external cavity were used as tunable sources for photoluminescence excitation (PLE) spectroscopy. The method was demonstrated in the 720 nm-1070 nm spectral range using a few commercial laser diodes. The samples for PLE measurements were quantum-well structures grown on GaAs and on InP. The method is superior to standard PLE measurements using titanium sapphire laser because it can be extended to any spectral range where anti-reflection coated laser diodes are available

  20. Pressure pain sensitivity: A new method of stress measurement in patients with ischemic heart disease

    DEFF Research Database (Denmark)

    Bergmann, Natasha; Ballegaard, Søren; Holmager, Pernille

    2013-01-01

    to induce hyperalgesia.The aim of the present study was to evaluate hyperalgesia by pressure pain sensitivity (PPS) in patients with IHD, and compare PPS to questionnaires measuring depressive symptoms, reduced psychological wellbeing, and QOL as markers of stress. Design. A cross-sectional study of 361......Abstract Background. Chronic stress is prevalent in patients with ischemic heart disease (IHD) and worsens the long-term prognosis. Chronic stress is vaguely defined, but is associated with depressive symptoms, reduced psychological wellbeing, and reduced quality of life (QOL). Stress seems...... subjects with IHD. Methods. PPS was measured on the sternum, and compared to the questionnaires: Clinical stress symptoms score (CSS), Major Depression Inventory (MDI), WHO-5 Wellbeing Index, and SF-36 QOL score. Results. PPS correlated to CSS (r = 0.20, p

  1. Signal quality measures for unsupervised blood pressure measurement

    International Nuclear Information System (INIS)

    Abdul Sukor, J; Redmond, S J; Lovell, N H; Chan, G S H

    2012-01-01

    Accurate systolic and diastolic pressure estimation, using automated blood pressure measurement, is difficult to achieve when the transduced signals are contaminated with noise or interference, such as movement artifact. This study presents an algorithm for automated signal quality assessment in blood pressure measurement by determining the feasibility of accurately detecting systolic and diastolic pressures when corrupted with various levels of movement artifact. The performance of the proposed algorithm is compared to a manually annotated reference scoring (RS). Based on visual representations and audible playback of Korotkoff sounds, the creation of the RS involved two experts identifying sections of the recorded sounds and annotating sections of noise contamination. The experts determined the systolic and diastolic pressure in 100 recorded Korotkoff sound recordings, using a simultaneous electrocardiograph as a reference signal. The recorded Korotkoff sounds were acquired from 25 healthy subjects (16 men and 9 women) with a total of four measurements per subject. Two of these measurements contained purposely induced noise artifact caused by subject movement. Morphological changes in the cuff pressure signal and the width of the Korotkoff pulse were extracted features which were believed to be correlated with the noise presence in the recorded Korotkoff sounds. Verification of reliable Korotkoff pulses was also performed using extracted features from the oscillometric waveform as recorded from the inflatable cuff. The time between an identified noise section and a verified Korotkoff pulse was the key feature used to determine the validity of possible systolic and diastolic pressures in noise contaminated Korotkoff sounds. The performance of the algorithm was assessed based on the ability to: verify if a signal was contaminated with any noise; the accuracy, sensitivity and specificity of this noise classification, and the systolic and diastolic pressure

  2. Influence of Individual Differences on the Calculation Method for FBG-Type Blood Pressure Sensors.

    Science.gov (United States)

    Koyama, Shouhei; Ishizawa, Hiroaki; Fujimoto, Keisaku; Chino, Shun; Kobayashi, Yuka

    2016-12-28

    In this paper, we propose a blood pressure calculation and associated measurement method that by using a fiber Bragg grating (FBG) sensor. There are several points at which the pulse can be measured on the surface of the human body, and when a FBG sensor located at any of these points, the pulse wave signal can be measured. The measured waveform is similar to the acceleration pulse wave. The pulse wave signal changes depending on several factors, including whether or not the individual is healthy and/or elderly. The measured pulse wave signal can be used to calculate the blood pressure using a calibration curve, which is constructed by a partial least squares (PLS) regression analysis using a reference blood pressure and the pulse wave signal. In this paper, we focus on the influence of individual differences from calculated blood pressure based on each calibration curve. In our study, the calculated blood pressure from both the individual and overall calibration curves were compared, and our results show that the calculated blood pressure based on the overall calibration curve had a lower measurement accuracy than that based on an individual calibration curve. We also found that the influence of the individual differences on the calculated blood pressure when using the FBG sensor method were very low. Therefore, the FBG sensor method that we developed for measuring the blood pressure was found to be suitable for use by many people.

  3. Measurement of response time and detection of degradation in pressure sensor/sensing-line systems

    International Nuclear Information System (INIS)

    Buchanan, M.E.; Miller, L.F.; Kerlin, T.W.; Ragan, G.; March-Leuba, J.; Thie, J.A.

    1985-01-01

    A team evaluated several methods for remote measurement of the response time and detection of degradation (blockage or air in lines) of pressure sensor/sensing line systems typical of nuclear power plants. A method was developed for obtaining the response time of force-balance pressure transmitters by briefly interrupting the power supply to the transmitter. The data thus generated are then analyzed in conjunction with a model to predict transmitter response to an actual pressure perturbation. The research team also evaluated a pressure perturbation method for determining the asymptotic delay time of a pressure-sensing line and found that this method yields accurate results for essentially unblocked sensing lines. However, these pressure perturbation tests are not recommended for use in nuclear power plants because they are difficult to implement on-line. A third method for remote measurement applied noise analysis method that yielded accurate estimates of asymptotic delay times for blockage or air in sensing lines. Even though noise analysis methods worked well in the laboratory, it is recommended that further evaluation be performed in operating nuclear plants. (orig.)

  4. Measurement of response time and detection of degradation in pressure sensor/sensing line systems

    International Nuclear Information System (INIS)

    Buchanan, M.E.; Miller, L.F.; Thie, J.A.; Kerlin, T.W.; Ragan, G.E.; March-Leuba, J.

    1985-09-01

    A team evaluated several methods for remote measurement of the response time and detection of degradation (blockage or air in lines) of pressure sensor/sensing line systems typical of nuclear power plants. A method was developed for obtaining the response time of force-balance pressure transmitters by briefly interrupting the power supply to the transmitter. The data thus generated are then analyzed in conjunction with a model to predict transmitter response to an actual pressure perturbation. The research team also evaluated a pressure perturbation method for determining the asymptotic delay time of a pressure-sensing line and found that this method yields accurate results for essentially unblocked sensing lines. However, these pressure perturbation tests are not recommended for use in nuclear power plants because they are difficult to implement on-line. A third method for remote measurement applied noise analysis methods that yielded accurate estimates of asymptotic delay times for blockage or air in sensing lines. Even though noise analysis methods worked well in the laboratory, it is recommended that further evaluation be performed in operating nuclear plants

  5. Assessing the accuracy of Greenland ice sheet ice ablation measurements by pressure transducer

    Science.gov (United States)

    Fausto, R. S.; van As, D.; Ahlstrøm, A. P.

    2012-04-01

    In the glaciological community there is a need for reliable mass balance measurements of glaciers and ice sheets, ranging from daily to yearly time scales. Here we present a method to measure ice ablation using a pressure transducer. The pressure transducer is drilled into the ice, en-closed in a hose filled with a liquid that is non-freezable at common Greenlandic temperatures. The pressure signal registered by the transducer is that of the vertical column of liquid over the sensor, which can be translated in depth knowing the density of the liquid. As the free-standing AWS moves down with the ablating surface and the hose melts out of the ice, an increasingly large part of the hose will lay flat on the ice surface, and the hydrostatic pressure from the vertical column of liquid in the hose will get smaller. This reduction in pressure provides us with the ablation rate. By measuring at (sub-) daily timescales this assembly is well-suited to monitor ice ablation in remote regions, with clear advantages over other well-established methods of measuring ice ablation in the field. The pressure transducer system has the potential to monitor ice ablation for several years without re-drilling and the system is suitable for high ablation areas. A routine to transform raw measurements into ablation values will also be presented, including a physically based method to remove air pressure variability from the signal. The pressure transducer time-series is compared to that recorded by a sonic ranger for the climatically hostile setting on the Greenland ice sheet.

  6. A novel approach to office blood pressure measurement: 30-minute office blood pressure vs daytime ambulatory blood pressure

    NARCIS (Netherlands)

    Wel, M.C. van der; Buunk, I.E.; Weel, C. van; Thien, Th.; Bakx, J.C.

    2011-01-01

    PURPOSE: Current office blood pressure measurement (OBPM) is often not executed according to guidelines and cannot prevent the white-coat effect. Serial, automated, oscillometric OBPM has the potential to overcome both these problems. We therefore developed a 30-minute OBPM method that we compared

  7. A simple experimental arrangement for measuring the vapour pressures and sublimation enthalpies by the Knudsen effusion method: Application to DNA and RNA bases

    International Nuclear Information System (INIS)

    Barros, A.L.F. de; Medina, A.; Zappa, F.; Pereira, J.M.; Bessa, E.; Martins, M.H.P.; Coelho, L.F.S.; Wolff, W.; Castro Faria, N.V. de

    2006-01-01

    We measured the vapour pressure of several DNA and RNA bases-uracil, adenine, guanine, thymine and cytosine-in the 300-450 K range. In each case the sample mass loss rate was measured as function of temperature with a simple setup consisting of a commercial film deposition system and a homemade oven. Afterwards vapour pressure values were extracted from these data using the Knudsen effusion method. Sublimation enthalpy values, obtained from vapour pressure data by applying the Clausius-Clapeyron equation, are in very good agreement with literature values. The results suggest that crystal-based film thickness monitors may be useful in on-line cross-section measurements, monitoring the gas target thickness. They also show the viability of using this oven for producing a biomolecular gas target

  8. Reliable blood pressure self-measurement in the obstetric waiting room

    DEFF Research Database (Denmark)

    Wagner, Stefan; Kamper, C. H.; Rasmussen, Niels H

    2014-01-01

    Background: Patients often fail to adhere to clinical recommendations when using current blood pressure self-measurement (BPSM) methods and equipment. As existing BPSM equipment is not able to detect non-adherent behavior, this could result in misdiagnosis and treatment error. To overcome...... patients scheduled for self-measuring their blood pressure (BP) in the waiting room at an obstetrics department's outpatient clinic to perform an additional BPSM using ValidAid. We then compared the automatically measured and classified values from ValidAid with our manual observations. Results: We found...

  9. A variable pressure method for characterizing nanoparticle surface charge using pore sensors.

    Science.gov (United States)

    Vogel, Robert; Anderson, Will; Eldridge, James; Glossop, Ben; Willmott, Geoff

    2012-04-03

    A novel method using resistive pulse sensors for electrokinetic surface charge measurements of nanoparticles is presented. This method involves recording the particle blockade rate while the pressure applied across a pore sensor is varied. This applied pressure acts in a direction which opposes transport due to the combination of electro-osmosis, electrophoresis, and inherent pressure. The blockade rate reaches a minimum when the velocity of nanoparticles in the vicinity of the pore approaches zero, and the forces on typical nanoparticles are in equilibrium. The pressure applied at this minimum rate can be used to calculate the zeta potential of the nanoparticles. The efficacy of this variable pressure method was demonstrated for a range of carboxylated 200 nm polystyrene nanoparticles with different surface charge densities. Results were of the same order as phase analysis light scattering (PALS) measurements. Unlike PALS results, the sequence of increasing zeta potential for different particle types agreed with conductometric titration.

  10. Micro packaged MEMS pressure sensor for intracranial pressure measurement

    International Nuclear Information System (INIS)

    Liu Xiong; Yao Yan; Ma Jiahao; Zhang Zhaohua; Zhang Yanhang; Wang Qian; Ren Tianling

    2015-01-01

    This paper presents a micro packaged MEMS pressure sensor for intracranial pressure measurement which belongs to BioMEMS. It can be used in lumbar puncture surgery to measure intracranial pressure. Miniaturization is key for lumbar puncture surgery because the sensor must be small enough to allow it be placed in the reagent chamber of the lumbar puncture needle. The size of the sensor is decided by the size of the sensor chip and package. Our sensor chip is based on silicon piezoresistive effect and the size is 400 × 400 μm 2 . It is much smaller than the reported polymer intracranial pressure sensors such as liquid crystal polymer sensors. In terms of package, the traditional dual in-line package obviously could not match the size need, the minimal size of recently reported MEMS-based intracranial pressure sensors after packaging is 10 × 10 mm 2 . In this work, we are the first to introduce a quad flat no-lead package as the package form of piezoresistive intracranial pressure sensors, the whole size of the sensor is minimized to only 3 × 3 mm 2 . Considering the liquid measurement environment, the sensor is gummed and waterproof performance is tested; the sensitivity of the sensor is 0.9 × 10 −2 mV/kPa. (paper)

  11. Analysis of baseline, average, and longitudinally measured blood pressure data using linear mixed models.

    Science.gov (United States)

    Hossain, Ahmed; Beyene, Joseph

    2014-01-01

    This article compares baseline, average, and longitudinal data analysis methods for identifying genetic variants in genome-wide association study using the Genetic Analysis Workshop 18 data. We apply methods that include (a) linear mixed models with baseline measures, (b) random intercept linear mixed models with mean measures outcome, and (c) random intercept linear mixed models with longitudinal measurements. In the linear mixed models, covariates are included as fixed effects, whereas relatedness among individuals is incorporated as the variance-covariance structure of the random effect for the individuals. The overall strategy of applying linear mixed models decorrelate the data is based on Aulchenko et al.'s GRAMMAR. By analyzing systolic and diastolic blood pressure, which are used separately as outcomes, we compare the 3 methods in identifying a known genetic variant that is associated with blood pressure from chromosome 3 and simulated phenotype data. We also analyze the real phenotype data to illustrate the methods. We conclude that the linear mixed model with longitudinal measurements of diastolic blood pressure is the most accurate at identifying the known single-nucleotide polymorphism among the methods, but linear mixed models with baseline measures perform best with systolic blood pressure as the outcome.

  12. Capillary pressure-saturation relationships for porous granular materials: Pore morphology method vs. pore unit assembly method

    Science.gov (United States)

    Sweijen, Thomas; Aslannejad, Hamed; Hassanizadeh, S. Majid

    2017-09-01

    In studies of two-phase flow in complex porous media it is often desirable to have an estimation of the capillary pressure-saturation curve prior to measurements. Therefore, we compare in this research the capability of three pore-scale approaches in reproducing experimentally measured capillary pressure-saturation curves. To do so, we have generated 12 packings of spheres that are representative of four different glass-bead packings and eight different sand packings, for which we have found experimental data on the capillary pressure-saturation curve in the literature. In generating the packings, we matched the particle size distributions and porosity values of the granular materials. We have used three different pore-scale approaches for generating the capillary pressure-saturation curves of each packing: i) the Pore Unit Assembly (PUA) method in combination with the Mayer and Stowe-Princen (MS-P) approximation for estimating the entry pressures of pore throats, ii) the PUA method in combination with the hemisphere approximation, and iii) the Pore Morphology Method (PMM) in combination with the hemisphere approximation. The three approaches were also used to produce capillary pressure-saturation curves for the coating layer of paper, used in inkjet printing. Curves for such layers are extremely difficult to determine experimentally, due to their very small thickness and the presence of extremely small pores (less than one micrometer in size). Results indicate that the PMM and PUA-hemisphere method give similar capillary pressure-saturation curves, because both methods rely on a hemisphere to represent the air-water interface. The ability of the hemisphere approximation and the MS-P approximation to reproduce correct capillary pressure seems to depend on the type of particle size distribution, with the hemisphere approximation working well for narrowly distributed granular materials.

  13. Exhaust pressure pulsation observation from turbocharger instantaneous speed measurement

    Science.gov (United States)

    Macián, V.; Luján, J. M.; Bermúdez, V.; Guardiola, C.

    2004-06-01

    In internal combustion engines, instantaneous exhaust pressure measurements are difficult to perform in a production environment. The high temperature of the exhaust manifold and its pulsating character make its application to exhaust gas recirculation control algorithms impossible. In this paper an alternative method for estimating the exhaust pressure pulsation is presented. A numerical model is built which enables the exhaust pressure pulses to be predicted from instantaneous turbocharger speed measurements. Although the model is data based, a theoretical description of the process is also provided. This combined approach makes it possible to export the model for different engine operating points. Also, compressor contribution in the turbocharger speed pulsation is discussed extensively. The compressor contribution is initially neglected, and effects of this simplified approach are analysed.

  14. Plasma assisted measurements of alkali metal concentrations in pressurized combustion processes

    Energy Technology Data Exchange (ETDEWEB)

    Hernberg, R.; Haeyrinen, V. [Tampere Univ. of Technology (Finland). Dept. of Physics

    1996-12-01

    The plasma assisted method for continuous measurement of alkali concentrations in product gas flows of pressurized energy processes will be tested and applied at the 1.6 MW PFBC/G facility at Delft University of Technology in the Netherlands. During the reporting period the alkali measuring device has been tested under pressurized conditions at VTT Energy, DMT, Foster-Wheeler Energia and ABB Carbon. Measurements in Delft will be performed during 1996 after installation of the hot gas filter. The original plan for measurements in Delft has been postponed due to schedule delays in Delft. The results are expected to give information about the influence of different process conditions on the generation of alkali vapours, the comparison of different methods for alkali measurement and the specific performance of our system. This will be the first test of the plasma assisted measurement method in a gasification process. The project belongs to the Joule II extension program under contract JOU2-CT93-0431. (author)

  15. A simple technique for measurement of pressure in the tympanitic rumen of cattle.

    Science.gov (United States)

    Turner, C B; Whyte, T D

    1978-05-13

    The construction and method of use of a simple device for the non-invasive measurement of intra-rumenal pressure is outlined. Results obtained from calves suffering from increased intra-rumenal pressure (bloat) are shown. The method is capable of quantifying pressures involved in bloat and could be used to augment the visual assessment of bloat scoring.

  16. MRI measurements of intracranial pressure in the upright posture: The effect of the hydrostatic pressure gradient.

    Science.gov (United States)

    Alperin, Noam; Lee, Sang H; Bagci, Ahmet M

    2015-10-01

    To add the hydrostatic component of the cerebrospinal fluid (CSF) pressure to magnetic resonance imaging (MRI)-derived intracranial pressure (ICP) measurements in the upright posture for derivation of pressure value in a central cranial location often used in invasive ICP measurements. Additional analyses were performed using data previously collected from 10 healthy subjects scanned in supine and sitting positions with a 0.5T vertical gap MRI scanner (GE Medical). Pulsatile blood and CSF flows to and from the brain were quantified using cine phase-contrast. Intracranial compliance and pressure were calculated using a previously described method. The vertical distance between the location of the CSF flow measurement and a central cranial location was measured manually in the mid-sagittal T1 -weighted image obtained in the upright posture. The hydrostatic pressure gradient of a CSF column with similar height was then added to the MR-ICP value. After adjustment for the hydrostatic component, the mean ICP value was reduced by 7.6 mmHg. Mean ICP referenced to the central cranial level was -3.4 ± 1.7 mmHg compared to the unadjusted value of +4.3 ± 1.8 mmHg. In the upright posture, the hydrostatic pressure component needs to be added to the MRI-derived ICP values for compatibility with invasive ICP at a central cranial location. © 2015 Wiley Periodicals, Inc.

  17. Commentary on differential-pressure measurements at high reference pressures

    International Nuclear Information System (INIS)

    Hasbrouck, R.T.; Noyes, R.P.

    1981-01-01

    Some practical approaches to the difficult problems in calibrating and implementing differential-pressure measurements are discussed. The data presented were gathered several years ago in separate investigations. An attempt is made to compare the results of these investigations to the common mode concept as described by Peter K. Stein in his publication, The Measurement of Differential Quantities - Problems and Approaches. Although one of these investigations involed a 10,000- to 20,000-psi reference-pressure gas measured at an ambient temperature and the other a classic /sup Δ/P flow measurement of cryogenic temperature, the problems encountered were the same

  18. Eccentric pressurized tube for measuring creep rupture

    International Nuclear Information System (INIS)

    Schwab, P.R.

    1981-01-01

    Creep rupture is a long term failure mode in structural materials that occurs at high temperatures and moderate stress levels. The deterioration of the material preceding rupture, termed creep damage, manifests itself in the formation of small cavities on grain boundaries. To measure creep damage, sometimes uniaxial tests are performed, sometimes density measurements are made, and sometimes the grain boundary cavities are measured by microscopy techniques. The purpose of the present research is to explore a new method of measuring creep rupture, which involves measuring the curvature of eccentric pressurized tubes. Theoretical investigations as well as the design, construction, and operation of an experimental apparatus are included in this research

  19. A new method to normalize plantar pressure measurements for foot size and foot progression angle.

    NARCIS (Netherlands)

    Keijsers, N.L.; Stolwijk, N.M.; Nienhuis, B.; Duysens, J.E.J.

    2009-01-01

    Plantar pressure measurement provides important information about the structure and function of the foot and is a helpful tool to evaluate patients with foot complaints. In general, average and maximum plantar pressure of 6-11 areas under the foot are used to compare groups of subjects. However,

  20. Measurement of fast transient pressures

    International Nuclear Information System (INIS)

    Procaccia, Henri

    1978-01-01

    The accuracy, reliability and sensitivity of a pressure transducers define its principal static characteristics. When the quantity measured varies with time, the measurement carries a dynamic error and a delay depending on the frequency of this variation. Hence, when fast pressure changes in a fluid have to be determined, different kinds of pressure transducers can be used depending on their inherent dynamic characteristics which must be compared with those of the transient phenomenon to be analysed. The text describes the pressure transducers generally employed in industry for analysing such phenomenon and gives two practical applications developed in the EDF: the first submits the measurements and results of pump cavitation tests carried out at the Vitry II EDF power station; the second deals with hammer blows particularly noticed in nuclear power stations and required the use of transducers of exceptionally high performance such as strain gauge transducers and piezoelectric transducers (response time within 1m sec.) [fr

  1. Oscillometric blood pressure measurement: a simple method in screening for peripheral arterial disease

    DEFF Research Database (Denmark)

    Mehlsen, Jesper; Wiinberg, Niels; Bruce, Christopher

    2008-01-01

    Blood pressure at the ankle level is a reliable indicator of peripheral arterial disease (PAD) and the ankle brachial index (ABI) is a useful non-invasive screening tool for the early detection of atherosclerosis. In the first part of the study, systolic blood pressures obtained by oscillometry...... of PAD was sufficiently high in subjects over the age of 60 years to warrant screening. The ankle brachial index based on measurements with an oscillometric device was shown reliable in the exclusion of PAD, thereby fulfilling an important criterion for the use in screening....

  2. [Measuring the blood pressure in both arms is of little use; longitudinal study into blood pressure differences between both arms and its reproducibility in patients with diabetes mellitus type 2].

    Science.gov (United States)

    Kleefstra, N; Houweling, S T; Meyboom-de Jong, B; Bilo, H J G

    2007-07-07

    To determine the prevalence of inter-arm blood pressure differences > 10 mmHg in patients with diabetes mellitus type 2 (DM2) and to determine whether these differences are consistent over time. Descriptive. In an evaluation study of 169 DM2 patients from 5 general practices in 2003 and 2004, different methods of oscillatory measurement were used to investigate inter-arm blood pressure differences > 10 mmHg systolic or diastolic. These methods were: one measurement in each arm non-simultaneously (method A), one measurement simultaneously (B) and the mean of two simultaneous measurements (C). With method A an inter-arm blood pressure difference was found in 33% of patients. This percentage diminished to 9 with method C. In 44% (n = 7) of the patients in whom method C detected a relevant blood pressure difference, this difference was not found with method A. In 79% of patients the inter-arm blood pressure difference was not reproduced after one year. In daily practice, one non-simultaneous blood pressure measurement in each arm (method A) was of little value for identification of patients with inter-arm blood pressure differences. The reproducibility was poor one year later. Bilateral blood pressure measurement is therefore of little value.

  3. Pancreas tumor interstitial pressure catheter measurement

    Science.gov (United States)

    Nieskoski, Michael D.; Gunn, Jason; Marra, Kayla; Trembly, B. Stuart; Pogue, Brian W.

    2016-03-01

    This paper highlights the methodology in measuring interstitial pressure in pancreatic adenocarcinoma tumors. A Millar Mikrotip pressure catheter (SPR-671) was used in this study and a system was built to amplify and filter the output signal for data collection. The Millar pressure catheter was calibrated prior to each experiment in a water column at 37°C, range of 0 to 60 inH2O (112 mmHg), resulting in a calibration factor of 33 mV / 1 inH2O. The interstitial pressures measured in two orthotopically grown pancreatic adenocarcinoma tumor were 57 mmHg and 48 mmHg, respectively. Verteporfin uptake into the pancreatic adenocarcinoma tumor was measured using a probe-based experimental dosimeter.

  4. The making of pressure measurement device on heating-02 based realtime

    International Nuclear Information System (INIS)

    Giarno; Kussigit Santosa; Agus Nur Rachman; G B Heru K

    2013-01-01

    In order to modify the installation strand BETA Test Section Test integrated with heating-02 into a closed loop, it would require an additional system that can measure pressure changes in the closed-loop system. By making the measurement device to test the system pressure at the heating-expected 02 researchers can monitor the pressure changes that occur in the system. The pressure gauge device fabrication using manufacturing simulation methodology, the preparation of the hardware and software and test functions. Manufacturing simulation using measuring devices HIOKI DC current source Signal Source, preparation of pressure measurement devices require hardware such as pressure transducers, NI cRIO-9074, NI 9203 analog module, Computer and software LabVIEW 2011 as programming. In the test process function method is used to provide flow simulation module that is connected to the 9203 NI NI cRIO-9074. Current provision tailored to the specifics pressure transducer is 4 mA s/d 20 mA. Based on the test results obtained function value of the lowest current is 4.00 mA = 0.001 bar, and the highest current value of 20.00 mA = 4995 bar. From the results of calculations using the linear equations obtained correlation coefficient (R 2 ) of 0.999, so it is evident that the pressure changes in LabVIEW is affected by changes in flow. The results obtained from this activity is a device that can measure the pressure in the heating-02 test. (author)

  5. Dynamic pressure measures for long pipeline leak detection

    Energy Technology Data Exchange (ETDEWEB)

    Likun Wang; Hongchao Wang; Min Xiong; Bin Xu; Dongjie Tan; Hengzhang Zhou [PetroChina Pipeline Company, Langfang (China). R and D Center

    2009-07-01

    Pipeline leak detection method based on dynamic pressure is studied. The feature of dynamic pressure which is generated by the leakage of pipeline is analyzed. The dynamic pressure method is compared with the static pressure method for the advantages and disadvantages in pipeline leak detection. The dynamic pressure signal is suitable for pipeline leak detection for quick-change of pipeline internal pressure. Field tests show that the dynamic pressure method detects pipeline leak rapidly and precisely. (author)

  6. Fast Neutral Pressure Measurements in NSTX

    International Nuclear Information System (INIS)

    R. Raman; H.W. Kugel; T. Provost; R. Gernhardt; T.R. Jarboe; M.G. Bell

    2002-01-01

    Several fast neutral pressure gauges have been installed on NSTX [National Spherical Torus Experiment] to measure the vessel and divertor pressure during inductive and coaxial helicity injected (CHI) plasma operations. Modified, PDX [Poloidal Divertor Experiment]-type Penning gauges have been installed on the upper and lower divertors. Neutral pressure measurements during plasma operations from these and from two shielded fast Micro ion gauges at different toroidal locations on the vessel mid-plane are described. A new unshielded ion gauge, referred to as the In-vessel Neutral Pressure (INP) gauge is under development

  7. Dynamic pressure as a measure of gas turbine engine (GTE) performance

    International Nuclear Information System (INIS)

    Rinaldi, G; Stiharu, I; Packirisamy, M; Nerguizian, V; Landry, R Jr; Raskin, J-P

    2010-01-01

    Utilizing in situ dynamic pressure measurement is a promising novel approach with applications for both control and condition monitoring of gas turbine-based propulsion systems. The dynamic pressure created by rotating components within the engine presents a unique opportunity for controlling the operation of the engine and for evaluating the condition of a specific component through interpretation of the dynamic pressure signal. Preliminary bench-top experiments are conducted with dc axial fans for measuring fan RPM, blade condition, surge and dynamic temperature variation. Also, a method, based on standing wave physics, is presented for measuring the dynamic temperature simultaneously with the dynamic pressure. These tests are implemented in order to demonstrate the versatility of dynamic pressure-based diagnostics for monitoring several different parameters, and two physical quantities, dynamic pressure and dynamic temperature, with a single sensor. In this work, the development of a dynamic pressure sensor based on micro-electro-mechanical system technology for in situ gas turbine engine condition monitoring is presented. The dynamic pressure sensor performance is evaluated on two different gas turbine engines, one having a fan and the other without

  8. Leak test method for radioactive material packagings without pressure valve connections

    International Nuclear Information System (INIS)

    Johnson, S.F.; Stenbaeck, A.

    1976-01-01

    A leak test method has been developed at Studsvik which provides the possibility of testing Type B packagings unequipped with valves for evacuation or pressurizing. Even large packagings with pressure valve connections can be leak tested by this method. The method is a pressure test method. The test gas comprises a mixture of helium and nitrogen or helium and air. Excess pressure in a valveless packaging is achieved by vaporization of liquid nitrogen. All parts of the packaging or package where leaks might be expected are covered by plastic sheet. Samples of the gas accumulated under the plastic sheets are taken using evacuated glass ampoules which are initially sealed off to a breakable point. The gas samples are measured with a He-mass spectrometer. The sensitivity of this method of leak testing is, in practice, of the order of 10 -7 atmcm 3 s -1 . (author)

  9. Low temperature measurement of the vapor pressures of planetary molecules

    Science.gov (United States)

    Kraus, George F.

    1989-01-01

    Interpretation of planetary observations and proper modeling of planetary atmospheres are critically upon accurate laboratory data for the chemical and physical properties of the constitutes of the atmospheres. It is important that these data are taken over the appropriate range of parameters such as temperature, pressure, and composition. Availability of accurate, laboratory data for vapor pressures and equilibrium constants of condensed species at low temperatures is essential for photochemical and cloud models of the atmospheres of the outer planets. In the absence of such data, modelers have no choice but to assume values based on an educated guess. In those cases where higher temperature data are available, a standard procedure is to extrapolate these points to the lower temperatures using the Clausius-Clapeyron equation. Last summer the vapor pressures of acetylene (C2H2) hydrogen cyanide (HCN), and cyanoacetylene (HC3N) was measured using two different methods. At the higher temperatures 1 torr and 10 torr capacitance manometers were used. To measure very low pressures, a technique was used which is based on the infrared absorption of thin film (TFIR). This summer the vapor pressure of acetylene was measured the TFIR method. The vapor pressure of hydrogen sulfide (H2S) was measured using capacitance manometers. Results for H2O agree with literature data over the common range of temperature. At the lower temperatures the data lie slightly below the values predicted by extrapolation of the Clausius-Clapeyron equation. Thin film infrared (TFIR) data for acetylene lie significantly below the values predicted by extrapolation. It is hoped to bridge the gap between the low end of the CM data and the upper end of the TFIR data in the future using a new spinning rotor gauge.

  10. Modern methods of high-pressure fuel pump common rail power system diagnostics

    Directory of Open Access Journals (Sweden)

    Kyshchun В.

    2016-08-01

    Full Text Available We've considered high pressure fuel pumps design features and equipment for their diagnosis. It was noted that the reliability of the fuel elements Common Rail system primarily provide precision parts of the fuel equipment. As a consequence, the aim of study was comparative analysis and laborious of modern methods of the high pressure fuel pump diagnosing. In particular, the definition of a technical condition of the fuel pump was carried out using a special stand and by measuring the fuel pressure and duty cycle of the pressure regulator signal. As an object of our research we've chosen Bosch № 0445010008 fuel pump (from Mercedes Benz E320cdi in which the plunger pairs were changed alternately with different technical conditions. Preliminary fuel pump parameters were determined by hydraulic testing. Based on conducted experiments we've found out that fuel pressure measurement change method and the duty cycle of the pressure regulator signal at the starting and full load modes less laborious compared to the definition of a technical condition of the pump on the stand. The results of both methods of diagnosing confirmed identity of the fuel pumps.

  11. Solid vapor pressure for five heavy PAHs via the Knudsen effusion method

    International Nuclear Information System (INIS)

    Fu Jinxia; Suuberg, Eric M.

    2011-01-01

    Highlights: → We report on vapor pressures and enthalpies of fusion and sublimation of five heavy PAHs. → Solid vapor pressures were measured using Knudsen effusion method. → Solid vapor pressures for benzo[b]fluoranthene, and indeno[1,2,3-cd]pyrene have not been published in the open literature. → Reported subcooled liquid state vapor pressures may or may not lend themselves to correction to sublimation vapor pressure. → Subcooled liquid state vapor pressures might sometimes actually be closer to actual solid state sublimation vapor pressures. - Abstract: Polycyclic aromatic hydrocarbons (PAHs) are compounds resulting from incomplete combustion and many fuel processing operations, and they are commonly found as subsurface environmental contaminants at sites of former manufactured gas plants. Knowledge of their vapor pressures is the key to predict their fate and transport in the environment. The present study involves five heavy PAHs, i.e. benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[ghi]perylene, indeno[1,2,3-cd]pyrene, and dibenz[a,h]anthracene, which are all as priority pollutants classified by the US EPA. The vapor pressures of these heavy PAHs were measured by using Knudsen effusion method over the temperature range of (364 to 454) K. The corresponding values of the enthalpy of sublimation were calculated from the Clausius-Clapeyron equation. The enthalpy of fusion for the five PAHs was also measured by using differential scanning calorimetry and used to convert earlier published sub-cooled liquid vapor pressure data to solid vapor pressure in order to compare with the present results. These adjusted values do not agree with the present measured actual solid vapor pressure values for these PAHs, but there is good agreement between present results and other earlier published sublimation data.

  12. Direct measurement of electron density in microdischarge at atmospheric pressure by Stark broadening

    International Nuclear Information System (INIS)

    Dong Lifang; Ran Junxia; Mao Zhiguo

    2005-01-01

    We present a method and results for measurement of electron density in atmospheric-pressure dielectric barrier discharge. The electron density of microdischarge in atmospheric pressure argon is measured by using the spectral line profile method. The asymmetrical deconvolution is used to obtain Stark broadening. The results show that the electron density in single filamentary microdischarge at atmospheric pressure argon is 3.05x10 15 cm -3 if the electron temperature is 10,000 K. The result is in good agreement with the simulation. The electron density in dielectric barrier discharge increases with the increase of applied voltage

  13. The influence of NDT-Bobath and PNF methods on the field support and total path length measure foot pressure (COP) in patients after stroke.

    Science.gov (United States)

    Krukowska, Jolanta; Bugajski, Marcin; Sienkiewicz, Monika; Czernicki, Jan

    In stroke patients, the NDT - (Bobath - Neurodevelopmental Treatment) and PNF (Proprioceptive Neuromuscular Facilitation) methods are used to achieve the main objective of rehabilitation, which aims at the restoration of maximum patient independence in the shortest possible period of time (especially the balance of the body). The aim of the study is to evaluate the effect of the NDT-Bobath and PNF methods on the field support and total path length measure foot pressure (COP) in patients after stroke. The study included 72 patients aged from 20 to 69 years after ischemic stroke with Hemiparesis. The patients were divided into 4 groups by a simple randomization. The criteria for this division were: the body side (right or left) affected by paresis and the applied rehabilitation methods. All the patients were applied the recommended kinesitherapeutic method (randomized), 35 therapy sessions, every day for a period of six weeks. Before initiation of therapy and after 6 weeks was measured the total area of the support and path length (COP (Center Of Pressure) measure foot pressure) using stabilometer platform - alpha. The results were statistically analyzed. After treatment studied traits decreased in all groups. The greatest improvement was obtained in groups with NDT-Bobath therapy. NDT-Bobath method for improving the balance of the body is a more effective method of treatment in comparison with of the PNF method. In stroke patients, the effectiveness of NDT-Bobath method does not depend on hand paresis. Copyright © 2016 Polish Neurological Society. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  14. Apparatus and method for direct measurement of coal ash sintering and fusion properties at elevated temperatures and pressures

    Science.gov (United States)

    Khan, M. Rashid

    1990-01-01

    A high-pressure microdilatometer is provided for measuring the sintering and fusion properties of various coal ashes under the influence of elevated pressures and temperatures in various atmospheres. Electrical resistivity measurements across a sample of coal ash provide a measurement of the onset of the sintering and fusion of the ash particulates while the contraction of the sample during sintering is measured with a linear variable displacement transducer for detecting the initiation of sintering. These measurements of sintering in coal ash at different pressures provide a mechanism by which deleterious problems due to the sintering and fusion of ash in various combustion systems can be minimized or obviated.

  15. A Direct Method for Mapping the Center of Pressure Measured by an Insole Pressure Sensor System to the Shoe's Local Coordinate System.

    Science.gov (United States)

    Weaver, Brian T; Braman, Jerrod E; Haut, Roger C

    2016-06-01

    A direct method to express the center of pressure (CoP) measured by an insole pressure sensor system (IPSS) into a known coordinate system measured by motion tracking equipment is presented. A custom probe was constructed with reflective markers to allow its tip to be precisely tracked with motion tracking equipment. This probe was utilized to activate individual sensors on an IPSS that was placed in a shoe fitted with reflective markers used to establish a local shoe coordinate system. When pressed onto the IPSS the location of the probe's tip was coincident with the CoP measured by the IPSS (IPSS-CoP). Two separate pushes (i.e., data points) were used to develop vectors in each respective coordinate system. Simple vector mathematics determined the rotational and translational components of the transformation matrix needed to express the IPSS-CoP into the local shoe coordinate system. Validation was performed by comparing IPSS-CoP with an embedded force plate measured CoP (FP-CoP) from data gathered during kinematic trials. Six male subjects stood on an embedded FP and performed anterior/posterior (AP) sway, internal rotation, and external rotation of the body relative to a firmly planted foot. The IPSS-CoP was highly correlated with the FP-CoP for all motions, root mean square errors (RMSRRs) were comparable to other research, and there were no statistical differences between the displacement of the IPSS-CoP and FP-CoP for both the AP and medial/lateral (ML) axes, respectively. The results demonstrated that this methodology could be utilized to determine the transformation variables need to express IPSS-CoP into a known coordinate system measured by motion tracking equipment and that these variables can be determined outside the laboratory anywhere motion tracking equipment is available.

  16. Measuring sub-bandage pressure: comparing the use of pressure monitors and pulse oximeters.

    Science.gov (United States)

    Satpathy, A; Hayes, S; Dodds, S R

    2006-03-01

    To test the use of low-cost sub-bandage pressure monitors and pulse oximeters as part of a quality-control measure for graduated compression bandaging in leg ulcer clinics. Twenty-five healthy volunteers (mean age 40 years) providing 50 limbs were bandaged with a four-layer compression bandaging system. The ankle systolic pressure (ASP) was measured using a pulse oximeter (Nellcor NBP-40) before applying the graduated compression bandages. Interface pressure was measured by placing pressure sensors on the skin at three points (2cm above the medial malleolus; the widest part of the calf; and a point midway between them) in the supine and standing positions. The ASP was measured again with the pulse oximeter after the bandage had been applied, and the effect of the bandage on the ASP was recorded. The actual pressure created by the bandage was compared with the required pressure profile. Interface pressures varied with change of position and movement. With the operator blinded to the pressure monitors while applying the bandages, the target pressure of 35-40mmHg at the ankle was achieved in only 36% of limbs ([mean +/- 95% confidence interval]; 32.3 +/- 1.6mmHg [supine]; 38.4 +/- 2.4mmHg [standing position]). With the help of the pressure monitors, the target pressure was achieved in 78% of the limbs. There was no correlation between the pressure monitors and pulse oximeter pressures, demonstrating that the pulse oximeter is not a useful tool for measuring sub-bandage pressures. The results suggest a tool (interface pressure monitors) that is easy to operate should be available as part of quality assurance for treatment, training of care providers and education.

  17. A synthetic-dynamic method for water solubility measurements in high pressure CO_2 using ATR–FTIR spectroscopy

    International Nuclear Information System (INIS)

    Comak, Gurbuz; Foltran, Stéphanie; Ke, Jie; Pérez, Eduardo; Sánchez-Vicente, Yolanda; George, Michael W.; Poliakoff, Martyn

    2016-01-01

    Highlights: • A synthetic method using ATR–FTIR spectroscopy has been developed to measure the solubility of water in CO_2_. • New data have been obtained for the dew point of the water at 4.05 MPa, 5.05 MPa and 6.03 MPa. • These data fill a gap in the literature and could be of significance for CO_2 transport in pipelines for CCS technology. - Abstract: A new synthetic method for studying phase behaviour is described using Attenuated Total Reflection (ATR) spectroscopy. The method has been developed to provide relevant information on the solubility of water in CO_2. The dew point of water has been determined at three different pressures, viz. (4.05, 5.05 and 6.03) MPa with mole fractions of water between 0.01 and 0.04. The data obtained fill the gap in the literature in these regions of pressures and temperatures and could be of high importance in the context of Carbon Capture and Storage (CCS) technology. Indeed, the presence of water in the captured CO_2 could damage the pipeline used for CO_2 transport. Hence, it is very important to have a fully understanding of the behaviour of the (CO_2 + H_2O) mixtures in wide range of temperature relevant for CCS.

  18. Measurement of lower leg compression in vivo: recommendations for the performance of measurements of interface pressure and stiffness: consensus statement.

    Science.gov (United States)

    Partsch, Hugo; Clark, Michael; Bassez, Sophie; Benigni, Jean-Patrick; Becker, Francis; Blazek, Vladimir; Caprini, Joseph; Cornu-Thénard, André; Hafner, Jürg; Flour, Mieke; Jünger, Michael; Moffatt, Christine; Neumann, Martino

    2006-02-01

    Interface pressure and stiffness characterizing the elastic properties of the material are the parameters determining the dosage of compression treatment and should therefore be measured in future clinical trials. To provide some recommendations regarding the use of suitable methods for this indication. This article was formulated based on the results of an international consensus meeting between a group of medical experts and representatives from the industry held in January 2005 in Vienna, Austria. Proposals are made concerning methods for measuring the interface pressure and for assessing the stiffness of a compression device in an individual patient. In vivo measurement of interface pressure is encouraged when clinical and experimental outcomes of compression treatment are to be evaluated.

  19. Prospective blood pressure measurement in renal transplant recipients.

    Science.gov (United States)

    David, V G; Yadav, B; Jeyaseelan, L; Deborah, M N; Jacob, S; Alexander, S; Varughese, S; John, G T

    2014-05-01

    Blood pressure (BP) control at home is difficult when managed only with office blood pressure monitoring (OBPM). In this prospective study, the reliability of BP measurements in renal transplant patients with OBPM and home blood pressure monitoring (HBPM) was compared with ambulatory blood pressure monitoring (ABPM) as the gold standard. Adult patients who had living-related renal transplantation from March 2007 to February 2008 had BP measured by two methods; OBPM and ABPM at pretransplantation, 2(nd), 4(th), 6(th), and 9(th) months and all the three methods: OBPM, ABPM, and HBPM at 6 months after transplantation. A total of 49 patients, age 35 ± 11 years, on prednisolone, tacrolimus, and mycophenolate were evaluated. A total of 39 were males (79.6%). Systolic BP (SBP) and diastolic BP (DBP) measured by OBPM were higher than HBPM when compared with ABPM. When assessed using OBPM and awake ABPM, both SBP and DBP were significantly overestimated by OBPM with mean difference of 3-12 mm Hg by office SBP and 6-8 mm Hg for office DBP. When HBPM was compared with mean ABPM at 6 months both the SBP and DBP were overestimated by and 7 mm Hg respectively. At 6 months post transplantation, when compared with ABPM, OBPM was more specific than HBPM in diagnosing hypertension (98% specificity, Kappa: 0.88 vs. 89% specificity, Kappa: 0.71). HBPM was superior to OBPM in identifying patients achieving goal BP (89% specificity, Kappa: 0.71 vs. 50% specificity Kappa: 0.54). In the absence of a gold standard for comparison the latent class model analysis still showed that ABPM was the best tool for diagnosing hypertension and monitoring patients reaching targeted control. OBPM remains an important tool for the diagnosis and management of hypertension in renal transplant recipients. HBPM and ABPM could be used to achieve BP control.

  20. Prospective blood pressure measurement in renal transplant recipients

    Directory of Open Access Journals (Sweden)

    V G David

    2014-01-01

    Full Text Available Blood pressure (BP control at home is difficult when managed only with office blood pressure monitoring (OBPM. In this prospective study, the reliability of BP measurements in renal transplant patients with OBPM and home blood pressure monitoring (HBPM was compared with ambulatory blood pressure monitoring (ABPM as the gold standard. Adult patients who had living-related renal transplantation from March 2007 to February 2008 had BP measured by two methods; OBPM and ABPM at pretransplantation, 2 nd , 4 th , 6 th , and 9 th months and all the three methods : OBPM, ABPM, and HBPM at 6 months after transplantation. A total of 49 patients, age 35 ± 11 years, on prednisolone, tacrolimus, and mycophenolate were evaluated. A total of 39 were males (79.6%. Systolic BP (SBP and diastolic BP (DBP measured by OBPM were higher than HBPM when compared with ABPM. When assessed using OBPM and awake ABPM, both SBP and DBP were significantly overestimated by OBPM with mean difference of 3-12 mm Hg by office SBP and 6-8 mm Hg for office DBP. When HBPM was compared with mean ABPM at 6 months both the SBP and DBP were overestimated by and 7 mm Hg respectively. At 6 months post transplantation, when compared with ABPM, OBPM was more specific than HBPM in diagnosing hypertension (98% specificity, Kappa : 0.88 vs. 89% specificity, Kappa : 0.71. HBPM was superior to OBPM in identifying patients achieving goal BP (89% specificity, Kappa : 0.71 vs. 50% specificity Kappa : 0.54. In the absence of a gold standard for comparison the latent class model analysis still showed that ABPM was the best tool for diagnosing hypertension and monitoring patients reaching targeted control. OBPM remains an important tool for the diagnosis and management of hypertension in renal transplant recipients. HBPM and ABPM could be used to achieve BP control.

  1. Assessing pharmacy students' ability to accurately measure blood pressure using a blood pressure simulator arm.

    Science.gov (United States)

    Bottenberg, Michelle M; Bryant, Ginelle A; Haack, Sally L; North, Andrew M

    2013-06-12

    To compare student accuracy in measuring normal and high blood pressures using a simulator arm. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; pdifference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign.

  2. Automated measurement of pressure injury through image processing.

    Science.gov (United States)

    Li, Dan; Mathews, Carol

    2017-11-01

    To develop an image processing algorithm to automatically measure pressure injuries using electronic pressure injury images stored in nursing documentation. Photographing pressure injuries and storing the images in the electronic health record is standard practice in many hospitals. However, the manual measurement of pressure injury is time-consuming, challenging and subject to intra/inter-reader variability with complexities of the pressure injury and the clinical environment. A cross-sectional algorithm development study. A set of 32 pressure injury images were obtained from a western Pennsylvania hospital. First, we transformed the images from an RGB (i.e. red, green and blue) colour space to a YC b C r colour space to eliminate inferences from varying light conditions and skin colours. Second, a probability map, generated by a skin colour Gaussian model, guided the pressure injury segmentation process using the Support Vector Machine classifier. Third, after segmentation, the reference ruler - included in each of the images - enabled perspective transformation and determination of pressure injury size. Finally, two nurses independently measured those 32 pressure injury images, and intraclass correlation coefficient was calculated. An image processing algorithm was developed to automatically measure the size of pressure injuries. Both inter- and intra-rater analysis achieved good level reliability. Validation of the size measurement of the pressure injury (1) demonstrates that our image processing algorithm is a reliable approach to monitoring pressure injury progress through clinical pressure injury images and (2) offers new insight to pressure injury evaluation and documentation. Once our algorithm is further developed, clinicians can be provided with an objective, reliable and efficient computational tool for segmentation and measurement of pressure injuries. With this, clinicians will be able to more effectively monitor the healing process of pressure

  3. Agreement between direct and indirect blood pressure measurements obtained from anesthetized Hispaniolan Amazon parrots.

    Science.gov (United States)

    Acierno, Mark J; da Cunha, Anderson; Smith, Julie; Tully, Thomas N; Guzman, David Sanchez-Migallon; Serra, Verna; Mitchell, Mark A

    2008-11-15

    To determine the level of agreement between direct and indirect blood pressure measurements obtained from healthy Hispaniolan Amazon parrots (Amazona ventralis) anesthetized with isoflurane. Validation study. 16 healthy adult Hispaniolan Amazon parrots. Parrots were anesthetized, and a 26-gauge, 19-mm catheter was placed percutaneously in the superficial ulnar artery for direct measurement of systolic, mean, and diastolic arterial pressures. Indirect blood pressure measurements were obtained with a Doppler ultrasonic flow detector and an oscillometric unit. The Bland-Altman method was used to compare direct and indirect blood pressure values. There was substantial disagreement between direct systolic arterial blood pressure and indirect blood pressure measurements obtained with the Doppler detector from the wing (bias, 24 mm Hg; limits of agreement, -37 to 85 mm Hg) and from the leg (bias, 14 mm Hg; limits of agreement, -14 to 42 mm Hg). Attempts to obtain indirect blood pressure measurements with the oscillometric unit were unsuccessful. Results suggested that there was substantial disagreement between indirect blood pressure measurements obtained with a Doppler ultrasonic flow detector in anesthetized Hispaniolan Amazon parrots and directly measured systolic arterial blood pressure.

  4. Delay Pressure Detection Method to Eliminate Pump Pressure Interference on the Downhole Mud Pressure Signals

    Directory of Open Access Journals (Sweden)

    Yue Shen

    2013-01-01

    Full Text Available The feasibility of applying delay pressure detection method to eliminate mud pump pressure interference on the downhole mud pressure signals is studied. Two pressure sensors mounted on the mud pipe in some distance apart are provided to detect the downhole mud continuous pressure wave signals on the surface according to the delayed time produced by mud pressure wave transmitting between the two sensors. A mathematical model of delay pressure detection is built by analysis of transmission path between mud pump pressure interference and downhole mud pressure signals. Considering pressure signal transmission characteristics of the mud pipe, a mathematical model of ideal low-pass filter for limited frequency band signal is introduced to study the pole frequency impact on the signal reconstruction and the constraints of pressure sensor distance are obtained by pole frequencies analysis. Theoretical calculation and numerical simulation show that the method can effectively eliminate mud pump pressure interference and the downhole mud continuous pressure wave signals can be reconstructed successfully with a significant improvement in signal-to-noise ratio (SNR in the condition of satisfying the constraints of pressure sensor distance.

  5. Development of a Blood Pressure Measurement Instrument with Active Cuff Pressure Control Schemes

    Directory of Open Access Journals (Sweden)

    Chung-Hsien Kuo

    2017-01-01

    Full Text Available This paper presents an oscillometric blood pressure (BP measurement approach based on the active control schemes of cuff pressure. Compared with conventional electronic BP instruments, the novelty of the proposed BP measurement approach is to utilize a variable volume chamber which actively and stably alters the cuff pressure during inflating or deflating cycles. The variable volume chamber is operated with a closed-loop pressure control scheme, and it is activated by controlling the piston position of a single-acting cylinder driven by a screw motor. Therefore, the variable volume chamber could significantly eliminate the air turbulence disturbance during the air injection stage when compared to an air pump mechanism. Furthermore, the proposed active BP measurement approach is capable of measuring BP characteristics, including systolic blood pressure (SBP and diastolic blood pressure (DBP, during the inflating cycle. Two modes of air injection measurement (AIM and accurate dual-way measurement (ADM were proposed. According to the healthy subject experiment results, AIM reduced 34.21% and ADM reduced 15.78% of the measurement time when compared to a commercial BP monitor. Furthermore, the ADM performed much consistently (i.e., less standard deviation in the measurements when compared to a commercial BP monitor.

  6. Optical measurement of acoustic radiation pressure of the near-field acoustic levitation through transparent object

    OpenAIRE

    Nakamura, Satoshi; Furusawa, Toshiaki; Sasao, Yasuhiro; Katsura, Kogure; Naoki, Kondo

    2013-01-01

    It is known that macroscopic objects can be levitated for few to several hundred micrometers by near-field acoustic field and this phenomenon is called near-field acoustic levitation (NFAL). Although there are various experiments conducted to measure integrated acoustic pressure on the object surface, up to now there was no direct method to measure pressure distribution. In this study we measured the acoustic radiation pressure of the near-field acoustic levitation via pressure-sensitive paint.

  7. Measurement of pressure on a surface using bubble acoustic resonances

    International Nuclear Information System (INIS)

    Aldham, Ben; Manasseh, Richard; Liffman, Kurt; Šutalo, Ilija D; Illesinghe, Suhith; Ooi, Andrew

    2010-01-01

    The frequency response of gas bubbles as a function of liquid ambient pressure was measured and compared with theory. A bubble size with equivalent spherical radius of 2.29 mm was used over a frequency range of 1000–1500 Hz. The ultimate aim is to develop an acoustic sensor that can measure static pressure and is sensitive to variations as small as a few kPa. The classical bubble resonance frequency is known to vary with ambient pressure. Experiments were conducted with a driven bubble in a pressurizable tank with a signal processing system designed to extract the resonant peak. Since the background response of the containing tank is significant, particularly near tank-modal resonances, it must be carefully removed from the bubble response signal. A dual-hydrophone method was developed to allow rapid and reliable real-time measurements. The expected pressure dependence was found. In order to obtain a reasonable match with theory, the classical theory was modified by the introduction of a 'mirror bubble' to account for the influence of a nearby surface. (technical design note)

  8. Fiber optic pressure sensors in skin-friction measurements

    Science.gov (United States)

    Cuomo, F. W.

    1986-01-01

    A fiber optic lever sensing technique that can be used to measure normal pressure as well as shear stresses is discussed. This method uses three unequal fibers combining small size and good sensitivity. Static measurements appear to confirm the theoretical models predicted by geometrical optics and dynamic tests performed at frequencies up to 10 kHz indicate a flat response within this frequency range. These sensors are intended for use in a low speed wind tunnel environment.

  9. Reproduction of pressure field in ultrasonic-measurement-integrated simulation of blood flow.

    Science.gov (United States)

    Funamoto, Kenichi; Hayase, Toshiyuki

    2013-07-01

    Ultrasonic-measurement-integrated (UMI) simulation of blood flow is used to analyze the velocity and pressure fields by applying feedback signals of artificial body forces based on differences of Doppler velocities between ultrasonic measurement and numerical simulation. Previous studies have revealed that UMI simulation accurately reproduces the velocity field of a target blood flow, but that the reproducibility of the pressure field is not necessarily satisfactory. In the present study, the reproduction of the pressure field by UMI simulation was investigated. The effect of feedback on the pressure field was first examined by theoretical analysis, and a pressure compensation method was devised. When the divergence of the feedback force vector was not zero, it influenced the pressure field in the UMI simulation while improving the computational accuracy of the velocity field. Hence, the correct pressure was estimated by adding pressure compensation to remove the deteriorating effect of the feedback. A numerical experiment was conducted dealing with the reproduction of a synthetic three-dimensional steady flow in a thoracic aneurysm to validate results of the theoretical analysis and the proposed pressure compensation method. The ability of the UMI simulation to reproduce the pressure field deteriorated with a large feedback gain. However, by properly compensating the effects of the feedback signals on the pressure, the error in the pressure field was reduced, exhibiting improvement of the computational accuracy. It is thus concluded that the UMI simulation with pressure compensation allows for the reproduction of both velocity and pressure fields of blood flow. Copyright © 2012 John Wiley & Sons, Ltd.

  10. Pressure measurements in harsh environments

    International Nuclear Information System (INIS)

    Cook, C.W.; Ames, E.S.

    1979-01-01

    A fluid coupled plate (FCP) gage was designed which allows pressure measurements to be made in harsh environments (including debris) using conventional pressure transducers. The pressure transducer is isolated by means of a rigid force plate which is supported by a bellows having one corrugation. This portion of the gage is machined from a single piece of material. The interior of the gage is filled with a phenol fluid which has a low compressibility

  11. Research on pipeline leak detection method based on pressure and dynamic pressure

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Likun; Xiong, Min; Zhao, Jinyun; Wang, Hongchao; Xu, Bin; Yu, DongLiang; Sun, Yi; Cai, Yongjun [RnD center of PetroChina Pipeline Company, Langfang, Hebei, (China)

    2010-07-01

    Pipeline leakages are very frequent and need to be detected as fast as possible to avoid safety and environment issues. Many leakage detection processes have been developed. Acoustic wave methods based on static pressure and dynamic pressure are both used for pipeline leakage detection. This study investigated a new pipeline leak detection method based on joint pressure and dynamic pressure. A dynamic pressure transmitter was designed based on a piezoelectric dynamic pressure sensor. The study showed that the dynamic pressure signal should be used for pipeline leak detection with a quick-change in pipeline internal pressure, while the static pressure signal provides better results with a slow-change of pipeline internal pressure. The in-field results showed that the location error of dynamic pressure is reduced to 80 m with a leakage ratio of 0.6 % pipeline throughput.

  12. Measurement of viscosity of gaseous mixtures at atmospheric pressure

    Science.gov (United States)

    Singh, J. J.; Mall, G. H.; Chegini, H.

    1986-01-01

    Coefficients of viscosity of various types of gas mixtures, including simulated natural-gas samples, have been measured at atmospheric pressure and room temperature using a modified capillary tube method. Pressure drops across the straight capillary tube section of a thermal mass flowmeter were measured for small, well-defined, volume flow rates for the test gases and for standard air. In this configuration, the flowmeter provides the volumetric flow rates as well as a well-characterized capillary section for differential pressure measurements across it. The coefficients of viscosity of the test gases were calculated using the reported value of 185.6 micro P for the viscosity of air. The coefficients of viscosity for the test mixtures were also calculated using Wilke's approximation of the Chapman-Enskog (C-E) theory. The experimental and calculated values for binary mixtures are in agreement within the reported accuracy of Wilke's approximation of the C-E theory. However, the agreement for multicomponent mixtures is less satisfactory, possible because of the limitations of Wilkes's approximation of the classical dilute-gas state model.

  13. Testing of acoustic emission method during pressure tests of WWER-440 steam generators and pressurizers

    International Nuclear Information System (INIS)

    Wuerfl, K.; Crha, J.

    1987-01-01

    The results are discussed of measuring acoustic emission in output pressure testing of steam generators and pressurizers for WWER-440 reactors. The objective of the measurements was to test the reproducibility of measurements and to find the criterion which would be used in assessing the condition of the components during manufacture and in operation. The acoustic emission was measured using a single-channel Dunegan/Endevco apparatus and a 16-channel LOCAMAT system. The results showed that after the first assembly, during a repeat dismantle of the lids and during seal replacement, processes due to seal contacts and bolt and washer deformations were the main source of acoustic emission. A procedure was defined of how to exclude new acoustic emission sources in such cases. The acoustic emission method can be used for the diagnostics of plastic deformation processes or of crack production and propagation in components during service. (Z.M.)

  14. Pressure measurements in magnetic-fusion devices

    International Nuclear Information System (INIS)

    Dylla, H.F.

    1981-11-01

    Accurate pressure measurements are important in magnetic fusion devices for: (1) plasma diagnostic measurements of particle balance and ion temperature; (2) discharge cleaning optimization; (3) vacuum system performance; and (4) tritium accountability. This paper reviews the application, required accuracy, and suitable instrumentation for these measurements. Demonstrated uses of ionization-type and capacitance-diaphragm gauges for various pressure and gas-flow measurements in tokamaks are presented, with specific reference to the effects of magnetic fields on gauge performance and the problems associated with gauge calibration

  15. Pressure measurements in magnetic-fusion devices

    Energy Technology Data Exchange (ETDEWEB)

    Dylla, H.F.

    1981-11-01

    Accurate pressure measurements are important in magnetic fusion devices for: (1) plasma diagnostic measurements of particle balance and ion temperature; (2) discharge cleaning optimization; (3) vacuum system performance; and (4) tritium accountability. This paper reviews the application, required accuracy, and suitable instrumentation for these measurements. Demonstrated uses of ionization-type and capacitance-diaphragm gauges for various pressure and gas-flow measurements in tokamaks are presented, with specific reference to the effects of magnetic fields on gauge performance and the problems associated with gauge calibration.

  16. Strain measurement in and analysis for hydraulic test of CPR1000 reactor pressure vessel

    International Nuclear Information System (INIS)

    Zhou Dan; Zhuang Dongzhen

    2013-01-01

    The strain measurement in hydraulic test of CPR1000 reactor pressure vessel performed in Dongfang Heavy Machinery Co., Ltd. is introduced. The detail test scheme and method was introduced and the measurement results of strain and stress was given. Meanwhile the finite element analysis was performed for the pressure vessel, which was generally matched with the measurement results. The reliability of strain measurement was verified and the high strength margin of vessel was shown, which would give a good reference value for the follow-up hydraulic tests and strength analysis of reactor pressure vessel. (authors)

  17. Pleural manometry-historical background, rationale for use and methods of measurement.

    Science.gov (United States)

    Zielinska-Krawczyk, Monika; Krenke, Rafal; Grabczak, Elzbieta M; Light, Richard W

    2018-03-01

    Subatmospheric pleural pressure (Ppl), which is approximately -3 to -5 cmH 2 O at functional residual capacity (FRC) makes pleura a unique organ in the human body. The negative Ppl is critical for maintaining the lungs in a properly inflated state and for proper blood circulation within the thorax. Significant and sudden pleural pressure changes associated with major pleural pathologies, as well as therapeutic interventions may be associated with life-threatening complications. The pleural pressure may show two different values depending on the measurement method applied. These are called pleural liquid pressure and pleural surface pressure. It should also be realized that there are significant differences in pleural pressure distribution in pneumothorax and pleural effusion. In pneumothorax, the pressure is the same throughout the pleural space, while in pleural effusion there is a vertical gradient of approximately 1 cm H 2 O/cm in the pleural pressure associated with the hydrostatic pressure of the fluid column. Currently, two main methods of pleural pressure measurement are used: simple water manometers and electronic systems. The water manometers are conceptually simple, cheap and user-friendly but they only allow the estimation of the mean values of pleural pressure. The electronic systems for pleural pressure measurement are based on pressure transducers. Their major advantages include precise measurements of instantaneous pleural pressure and the ability to display and to store a large amount of data. The paper presents principles and details of pleural pressure measurement as well as the rationale for its use. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. The measurement for level of marine high-temperature and high-pressure vessels

    International Nuclear Information System (INIS)

    Lin Jie.

    1986-01-01

    The various error factors in measurement for level of marine high-temperature and high-pressure vessels are anslysed. The measuring method of error self compensation and its simplification for land use are shown

  19. [The research in a foot pressure measuring system based on LabVIEW].

    Science.gov (United States)

    Li, Wei; Qiu, Hong; Xu, Jiang; He, Jiping

    2011-01-01

    This paper presents a system of foot pressure measuring system based on LabVIEW. The designs of hardware and software system are figured out. LabVIEW is used to design the application interface for displaying plantar pressure. The system can realize the plantar pressure data acquisition, data storage, waveform display, and waveform playback. It was also shown that the testing results of the system were in line with the changing trend of normal gait, which conformed to human system engineering theory. It leads to the demonstration of system reliability. The system gives vivid and visual results, and provides a new method of how to measure foot-pressure and some references for the design of Insole System.

  20. Determination of the response time of pressure transducers using the direct method

    International Nuclear Information System (INIS)

    Perillo, S.R.P.

    1994-01-01

    The available methods to determine the response time of nuclear safety related pressure transducers are discussed, with emphasis to the direct method. In order to perform the experiments, a Hydraulic Ramp Generator was built. The equipment produces ramp pressure transients simultaneously to a reference transducer and to the transducer under test. The time lag between the output of the two transducers, when they reach a predetermined setpoint, is measured as the time delay of the transducer under test. Some results using the direct method to determine the time delay of pressure transducers (1 E Class Conventional) are presented. (author). 18 refs, 35 figs, 12 tabs

  1. Photogrammetric methods of measurement in industrial applications

    International Nuclear Information System (INIS)

    Godding, R.; Groene, A.; Heinrich, G.; Schneider, C.T.

    1993-01-01

    Methods for 3D measurement are required for very varied applications in the industrial field. This includes tasks of quality assurance and plant monitoring, among others. It should be possible to apply the process flexibly it should require as short interruptions of production as possible and should meet the required accuracies. These requirements can be met by photogrammetric methods of measurement. The article introduces these methods and shows their capabilities from various selected examples (eg: the replacement of large components in a pressurized water reactor, and aircraft measurements (orig./DG) [de

  2. Measuring Vapor Pressure with an Isoteniscope: A Hands-on Introduction to Thermodynamic Concepts

    Science.gov (United States)

    Chen, Wenqian; Haslam, Andrew J.; Macey, Andrew; Shah, Umang V.; Brechtelsbauer, Clemens

    2016-01-01

    Characterization of the vapor pressure of a volatile liquid or azeotropic mixture, and its fluid phase diagram, can be achieved with an isoteniscope and an industrial grade digital pressure sensor using the experimental method reported in this study. We describe vapor-pressure measurements of acetone and n-hexane and their azeotrope, and how the…

  3. Comparison of high-definition oscillometry -- a non-invasive technology for arterial blood pressure measurement -- with a direct invasive method using radio-telemetry in awake healthy cats.

    Science.gov (United States)

    Martel, Eric; Egner, Beate; Brown, Scott A; King, Jonathan N; Laveissiere, Arnaud; Champeroux, Pascal; Richard, Serge

    2013-12-01

    This study compared indirect blood pressure measurements using a non-invasive method, high-definition oscillometry (HDO), with direct measurements using a radio-telemetry device in awake cats. Paired measurements partitioned to five sub-ranges were collected in six cats using both methods. The results were analysed for assessment of correlation and agreement between the two methods, taking into account all pressure ranges, and with data separated in three sub-groups, low, normal and high ranges of systolic (SBP) and diastolic (DBP) blood pressure. SBP data displayed a mean correlation coefficient of 0.92 ± 0.02 that was reduced for low SBP. The agreement level evaluated from the whole data set was high and slightly reduced for low SBP values. The mean correlation coefficient of DBP was lower than for SBP (ie, 0.81 ± 0.02). The bias for DBP between the two methods was 22.3 ± 1.6 mmHg, suggesting that HDO produced lower values than telemetry. These results suggest that HDO met the validation criteria defined by the American College of Veterinary Internal Medicine consensus panel and provided a faithful measurement of SBP in conscious cats. For DBP, results suggest that HDO tended to underestimate DBP. This finding is clearly inconsistent with the good agreement reported in dogs, but is similar to outcomes achieved in marmosets and cynomolgus monkeys, suggesting that this is not related to HDO but is species related. The data support that the HDO is the first and only validated non-invasive blood pressure device and, as such, it is the only non-invasive reference technique that should be used in future validation studies.

  4. Correlation between intrasac pressure measurements of a pressure sensor and an angiographic catheter during endovascular repair of abdominal aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Pierre Galvagni Silveira

    2008-01-01

    Full Text Available PURPOSE: To establish a correlation between intrasac pressure measurements of a pressure sensor and an angiographic catheter placed in the same aneurysm sac before and after its exclusion by an endoprosthesis. METHODS: Patients who underwent endovascular abdominal aortic aneurysm repair and received an EndoSureTM wireless pressure sensor implant between March 19 and December 11, 2004 were enrolled in the study. Simultaneous readings of systolic, diastolic, mean, and pulse pressure within the aneurysm sac were obtained from the catheter and the sensor, both before and after sac exclusion by the endoprosthesis (Readings 1 and 2, respectively. Intrasac pressure measurements were compared using Pearson's correlation and Student's t test. Statistical significance was set at p0.05, mean (p>0.05, and pulse (p0.05 by the sensor. CONCLUSION: The excellent agreement between intrasac pressure readings recorded by the catheter and the sensor justifies use of the latter for detection of post-exclusion abdominal aortic aneurysm pressurization.

  5. Should blood pressure be measured with the cuff on a bare arm?

    NARCIS (Netherlands)

    Thien, T.; Keltjens, E.B.; Lenders, J.W.M.; Deinum, J.

    2015-01-01

    OBJECTIVE: To establish whether the results of blood pressure (BP) measurements are affected by wearing clothing underneath the BP cuff during measurement. METHODS: Normotensive and hypertensive patients (n=133; 65 men) of an outpatient clinic participated in this study. BP was measured according to

  6. COMPARISON OF HIGH-DEFINITION OSCILLOMETRIC AND DIRECT ARTERIAL BLOOD PRESSURE MEASUREMENT IN ANESTHETIZED CHEETAHS (ACINONYX JUBATUS).

    Science.gov (United States)

    Sant Cassia, Emma V; Boswood, Adrian; Tordiffe, Adrian S W

    2015-09-01

    Blood pressure measurement reveals important insights into the health of conscious and anesthetized individuals. This is of particular interest in cheetahs (Acinonyx jubatus), which in captivity are known to suffer from chronic diseases that may be associated with hypertension and which often require immobilization for transport or veterinary treatment. Invasive testing methods are considered the gold standard but are not practical in many settings. Consequently, it is important to evaluate the use of noninvasive methods in this species. Measurements for systolic, diastolic, and mean arterial pressure obtained using high-definition oscillometry (HDO) at the coccygeal artery were compared to simultaneous direct measurements obtained via catheterization of the femoral or dorsal pedal artery in eight anesthetized captive cheetahs during nine anesthetic events. Overall, HDO and direct measurements agreed most closely for mean arterial pressure, and the poorest agreement was observed for systolic pressure. There was a tendency for low diastolic pressures to be underestimated and for high diastolic pressures to be overestimated. Across all three parameters, HDO measurements from the tail overestimated directly measured pressures in the femoral artery and underestimated those in the dorsal pedal artery. HDO agreed most closely with directly measured dorsal pedal pressures. Mean arterial pressure showed the greatest precision (standard deviation of 10.2 mm Hg) and lowest bias (-1.2 mm Hg), with 75.9% of readings within 10 mm Hg of the direct dorsal pedal pressure. Agreement with systolic pressure was hindered by a high bias (-10.4 mm Hg), but if a correction factor of +10 mm Hg was applied to all systolic measurements, agreement was improved and 65.7% of readings were within 10 mm Hg of the direct pressure. When compared to criteria defined by the American College of Veterinary Internal Medicine for validation of blood pressure devices, results were favorable, but a

  7. Measurement of hepatic venous pressure gradient revisited: Catheter wedge vs balloon wedge techniques

    Directory of Open Access Journals (Sweden)

    S Timothy Chelliah

    2011-01-01

    Full Text Available Aims: To evaluate the accuracy of measurement of hepatic venous pressure gradient by catheter wedge as compared to balloon wedge (the gold standard. Materials and Methods: Forty-five patients having a clinical diagnosis of intrahepatic portal hypertension were subjected to the two different types of pressure measurements (catheter wedge and balloon wedge during transjugular liver biopsy under fluoroscopic guidance. Statistical Analysis: Spearman′s rank correlation coefficient, Bland-Altman plot for agreement, and single measure intraclass correlation were used for analysis of data. Results: There was a close correlation between the results obtained by both the techniques, with highly significant concordance (P < 0.0001. Hepatic venous pressure gradients as measured by the catheter wedge technique were either equal to or less than those obtained by the balloon wedge technique. Conclusions: The difference in hepatic venous pressure gradients measured by the two techniques is insignificant.

  8. Noninvasive blood pressure measurement scheme based on optical fiber sensor

    Science.gov (United States)

    Liu, Xianxuan; Yuan, Xueguang; Zhang, Yangan

    2016-10-01

    Optical fiber sensing has many advantages, such as volume small, light quality, low loss, strong in anti-jamming. Since the invention of the optical fiber sensing technology in 1977, optical fiber sensing technology has been applied in the military, national defense, aerospace, industrial, medical and other fields in recent years, and made a great contribution to parameter measurement in the environment under the limited condition .With the rapid development of computer, network system, the intelligent optical fiber sensing technology, the sensor technology, the combination of computer and communication technology , the detection, diagnosis and analysis can be automatically and efficiently completed. In this work, we proposed a noninvasive blood pressure detection and analysis scheme which uses optical fiber sensor. Optical fiber sensing system mainly includes the light source, optical fiber, optical detector, optical modulator, the signal processing module and so on. wavelength optical signals were led into the optical fiber sensor and the signals reflected by the human body surface were detected. By comparing actual testing data with the data got by traditional way to measure the blood pressure we can establish models for predicting the blood pressure and achieve noninvasive blood pressure measurement by using spectrum analysis technology. Blood pressure measurement method based on optical fiber sensing system is faster and more convenient than traditional way, and it can get accurate analysis results in a shorter period of time than before, so it can efficiently reduce the time cost and manpower cost.

  9. Context-aware patient guidance during blood pressure self-measurement

    DEFF Research Database (Denmark)

    Sandager, Puk; Lindahl, Camilla; Schlütter, Jacob Mørup

    2013-01-01

    The importance of accurate measurement of blood pressure in the screening and management of hypertension during pregnancy is well established. Blood pressure levels can be measured manually by healthcare staff or by using a blood pressure self-measurement device, either at home or in the clinic...... the blood pressure self-measurement process. Preliminary results indicate that such active and context-aware guidance leads to more reliable measurements by inhibiting non-adherent patient behavior...

  10. Is a computer based measurement method superior to a recommended manual method by the ROHO® Group to assess pressure in the sitting position?

    DEFF Research Database (Denmark)

    Andreasen, Jane; Olesen, Christian Gammelgaard; Rasmussen, John

    2013-01-01

    at the Department of Occupational Therapy and Physiotherapy, Aalborg Hospital, Aarhus University Hospital, Denmark. Participants: 20 healthy and able minded aged between 18 and 65. Procedure: The outcome measures were obtained using a pressure imaging system that could register pressure distribution in the sitting...... area. The system was a XSENSOR Pressure Mapping System™. The cushion used was a Roho Quatro select® high profile. All subjects were tested twice with an interval of 24 hours by Testers 1 and 2, who were experienced occupational therapists. Main outcome measures: Risk factor defined as a scalar norm, R...

  11. Measurement of the non-thermal properties of a low pressure spraying plasma by electric and spectroscopic methods

    International Nuclear Information System (INIS)

    Jung, Yong Ho

    2003-02-01

    For the case of an atmospheric plasma, the local thermodynamic equilibrium (LTE) model can be applied to plasmas at a nozzle entrance and to those on the axis of the plasma flame, but it is not easy to justify applying the LTE model to off-center plasma and to a low-pressure spraying plasma. Although the energy distribution of the electrons is assumed to be Maxwellian for the most of spraying plasmas, the non-Maxwellian distribution is possible for the case of low-pressure spaying plasma and edge plasma of atmospheric spraying plasma. In this work, the non-Maxwellian distribution of electrons was measured by using an electric probe installed on the fast scanning probe system, and non-LTE effects were measured by using the optical emission spectroscopy system. Distribution of the electrons of a low-pressure spraying plasma is observed not as Maxwellian but as bi-Maxwellian by the measurement of the single probe. Bi-Maxwellian distribution appears in the edge of a low pressure spraying plasma and seems to be due to the reduction of the collisonality by the drastic variation of the plasma density. Non-LTE characteristics of a low-pressure spraying plasma can be deuced from the measured results of the optical emission spectroscopy and is analyzed by the collisional radiative equilibrium (CRE) model, where the Maxwellian and the non-Maxwellian distributions are assumed for comparison. For the electron temperature, the results from optical emission spectroscopy were similar to the results from the single probe (3∼5 % in error)

  12. Intracranial Pressure

    DEFF Research Database (Denmark)

    Hvedstrup, Jeppe; Radojicic, Aleksandra; Moudrous, Walid

    2018-01-01

    OBJECTIVE: To compare a new method of noninvasive intracranial pressure (nICP) measurement with conventional lumbar puncture (LP) opening pressure. METHODS: In a prospective multicenter study, patients undergoing LP for diagnostic purposes underwent intracranial pressure measurements with HeadSen...

  13. Extension of the heat flux method to subatmospheric pressures

    NARCIS (Netherlands)

    Bosschaart, K.J.; Goey, de L.P.H.

    2004-01-01

    The heat flux method for measuring laminar burning velocities has been extended to subatmospheric pressures, down to 80mbar. The new setup is described and adaptations necessary for the new conditions are analyzed. This includes a new burner plate to compensate for the decrease of sensitivity of the

  14. Betweenness-Based Method to Identify Critical Transmission Sectors for Supply Chain Environmental Pressure Mitigation.

    Science.gov (United States)

    Liang, Sai; Qu, Shen; Xu, Ming

    2016-02-02

    To develop industry-specific policies for mitigating environmental pressures, previous studies primarily focus on identifying sectors that directly generate large amounts of environmental pressures (a.k.a. production-based method) or indirectly drive large amounts of environmental pressures through supply chains (e.g., consumption-based method). In addition to those sectors as important environmental pressure producers or drivers, there exist sectors that are also important to environmental pressure mitigation as transmission centers. Economy-wide environmental pressure mitigation might be achieved by improving production efficiency of these key transmission sectors, that is, using less upstream inputs to produce unitary output. We develop a betweenness-based method to measure the importance of transmission sectors, borrowing the betweenness concept from network analysis. We quantify the betweenness of sectors by examining supply chain paths extracted from structural path analysis that pass through a particular sector. We take China as an example and find that those critical transmission sectors identified by betweenness-based method are not always identifiable by existing methods. This indicates that betweenness-based method can provide additional insights that cannot be obtained with existing methods on the roles individual sectors play in generating economy-wide environmental pressures. Betweenness-based method proposed here can therefore complement existing methods for guiding sector-level environmental pressure mitigation strategies.

  15. Elastic Wave Velocity Measurements on Mantle Peridotite at High Pressure and Temperature

    Science.gov (United States)

    Mistler, G. W.; Ishikawa, M.; Li, B.

    2002-12-01

    With the success of conducting ultrasonic measurements at high pressure and high temperature in large volume high pressure apparatus with in-situ measurement of the sample length by X-ray imaging, it is now possible to measure elastic wave velocities on aggregate samples with candidate compositions of the mantle to the conditions of the Earth's transition zone in the laboratory. These data can be directly compared with seismic data to distinguish the compositional models in debate. In this work, we carried out velocity measurements on natural peridotite KLB-1 at the conditions of the Earth's upper mantle. Fine powered sample of natural KLB-1 was used as starting material. Specimens for ultrasonic measurements were hot-pressed and equilibrated at various pressure and temperature conditions along geotherm up to the transition zone. The recovered samples were characterized with density measurement, X-ray diffraction and microprobe analysis. Bench top P and S wave velocities of KLB-1 sample sintered at 3-4 GPa and 1400 degree centigrade showed a very good agreement with the VRH average of pyrolite. High pressure and high temperature measurements was conducted up to 7 GPa and 800 degree centigrade using ultrasonic interferometric method in a DIA-type high pressure apparatus in conjunction with X-ray diffraction and X-ray imaging. The utilization of X-ray imaging technique provides direct measurements of sample lengths at high pressure and high temperature, ensuring a precise determination of velocities. The results of P and S wave velocities at high pressure and high temperature as well as their comparison with calculated pyrolite model will be presented.

  16. Pressure Measurement and Flowfield Characterization of a Two-Dimensional Ideally Expanded, Constant Area, Air/air Ejector.

    Science.gov (United States)

    Benjamin, Michael Anthony

    A detailed experimental investigation of a two -dimensional, Mach 1.8 air-primary, Mach 0.3 air-secondary ejector at high Reynolds number has been performed, from which a nonintrusive method for whole-field visualization using turbulent wall-pressure has been developed. The experiments were conducted using mean and time-accurate wall pressure measurements, impact-pressure measurements using a traversing probe, and Schlieren and shadowgraph visualization techniques. The time-accurate pressure measurements were recorded using a sealed Kulite miniature pressure transducer with a 0.7 mm diameter sensing diaphragm. For all except the optical methods, measurements were taken from the initial flow interface to about 13 hydraulic tube-diameters downstream in the constant-area mixing section. From the mean measurements, values of stagnation pressure, density, velocity, static pressure, Mach number, and dynamic pressure were developed and are presented. Using the time-accurate pressure measurements, a color contour plot of the rms pressure was developed that definitively shows the regions of the flow in agreement with the other measurements. Additionally, probability density functions, skewness, and kurtosis were calculated. Peak values of skewness (S) and kurtosis (K) on the centerline at about 2.5 hydraulic diameters are S = 1.85 and K = 11.5. The inlet rms pressure values, normalized by freestream dynamic pressure for the primary (~0.001), were found to be in fair agreement with previous experimental values; however, those in the secondary were much higher (~0.2), apparently due to the acoustic radiation from the primary. Fourier analysis of the time-accurate pressure measurements show that the autospectra contain k ^{-1}, k^{-7/3}, and k^{-11/3} pressure spectrum functions as predicted by prevailing theory for the overlap layer, turbulence-turbulence interaction, and turbulence-mean-shear interaction, respectively. It is believed that this is the first experiment in

  17. Innovation of fission gas release and thermal conductivity measurement methods

    International Nuclear Information System (INIS)

    Van der Meer, K.; Soboler, V.

    1998-01-01

    This presentation described two innovative measurement methods being currently developed at SCK-CEN in order to support the modeling of fuel performance. The first one is an acoustic method to measure the fission gas release in a fuel rod in a non destructive way. The total rod pressure is determined by generating a heat pulse causing a pressure wave that propagates through the gas to an ultrasound transducer. The final pulse width being proportional to the pressure, the latter can thus be determined. The measurement of the acoustic resonance frequency at fixed temperatures enables the distinction between different gas components. The second method is a non-stationary technique to investigate the thermal properties of the fuel rod, like thermal conductivity, diffusivity and heat capacity. These properties are derived from the amplitude and the phase shift of the fuel centre temperature response induced by a periodic temperature variation. These methods did not reveal any physical limitations for the practical applicability. Furthermore, they are rather simple. Preliminary investigations have proven both methods to be more accurate than techniques usually utilized. (author)

  18. Pressure History Measurement in a Microwave Beaming Thruster

    International Nuclear Information System (INIS)

    Oda, Yasuhisa; Ushio, Masato; Komurasaki, Kimiya; Takahashi, Koji; Kasugai, Atsushi; Sakamoto, Keishi

    2006-01-01

    In a microwave beaming thruster with a 1-dimensional nozzle, plasma and shock wave propagates in the nozzle absorbing microwave power. In this study, pressure histories in the thruster are measured using pressure gauges. Measured pressure history at the thruster wall shows constant pressure during plasma propagation in the nozzle. The result of measurement of the propagating velocities of shock wave and plasma shows that both propagate in the same velocity. These result shows that thrust producing model of analogy of pulse detonation engine is successful for the 1D thruster

  19. Experimental aspects of buoyancy correction in measuring reliable high-pressure excess adsorption isotherms using the gravimetric method

    Science.gov (United States)

    Nguyen, Huong Giang T.; Horn, Jarod C.; Thommes, Matthias; van Zee, Roger D.; Espinal, Laura

    2017-12-01

    Addressing reproducibility issues in adsorption measurements is critical to accelerating the path to discovery of new industrial adsorbents and to understanding adsorption processes. A National Institute of Standards and Technology Reference Material, RM 8852 (ammonium ZSM-5 zeolite), and two gravimetric instruments with asymmetric two-beam balances were used to measure high-pressure adsorption isotherms. This work demonstrates how common approaches to buoyancy correction, a key factor in obtaining the mass change due to surface excess gas uptake from the apparent mass change, can impact the adsorption isotherm data. Three different approaches to buoyancy correction were investigated and applied to the subcritical CO2 and supercritical N2 adsorption isotherms at 293 K. It was observed that measuring a collective volume for all balance components for the buoyancy correction (helium method) introduces an inherent bias in temperature partition when there is a temperature gradient (i.e. analysis temperature is not equal to instrument air bath temperature). We demonstrate that a blank subtraction is effective in mitigating the biases associated with temperature partitioning, instrument calibration, and the determined volumes of the balance components. In general, the manual and subtraction methods allow for better treatment of the temperature gradient during buoyancy correction. From the study, best practices specific to asymmetric two-beam balances and more general recommendations for measuring isotherms far from critical temperatures using gravimetric instruments are offered.

  20. Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects

    Directory of Open Access Journals (Sweden)

    Robert Koprowski

    2017-01-01

    Full Text Available Background. Blood pulsation affects the results obtained using various medical devices in many different ways. Method. The paper proves the effect of blood pulsation on intraocular pressure measurements. Six measurements for each of the 10 healthy subjects were performed in various phases of blood pulsation. A total of 8400 corneal deformation images were recorded. The results of intraocular pressure measurements were related to the results of heartbeat phases measured with a pulse oximeter placed on the index finger of the subject’s left hand. Results. The correlation between the heartbeat phase measured with a pulse oximeter and intraocular pressure is 0.69±0.26 (p<0.05. The phase shift calculated for the maximum correlation is equal to 60±40° (p<0.05. When the moment of measuring intraocular pressure with an air-puff tonometer is not synchronized, the changes in IOP for the analysed group of subjects can vary in the range of ±2.31 mmHg (p<0.3. Conclusions. Blood pulsation has a statistically significant effect on the results of intraocular pressure measurement. For this reason, in modern ophthalmic devices, the measurement should be synchronized with the heartbeat phases. The paper proposes an additional method for synchronizing the time of pressure measurement with the blood pulsation phase.

  1. Using the area under the curve to reduce measurement error in predicting young adult blood pressure from childhood measures.

    Science.gov (United States)

    Cook, Nancy R; Rosner, Bernard A; Chen, Wei; Srinivasan, Sathanur R; Berenson, Gerald S

    2004-11-30

    Tracking correlations of blood pressure, particularly childhood measures, may be attenuated by within-person variability. Combining multiple measurements can reduce this error substantially. The area under the curve (AUC) computed from longitudinal growth curve models can be used to improve the prediction of young adult blood pressure from childhood measures. Quadratic random-effects models over unequally spaced repeated measures were used to compute the area under the curve separately within the age periods 5-14 and 20-34 years in the Bogalusa Heart Study. This method adjusts for the uneven age distribution and captures the underlying or average blood pressure, leading to improved estimates of correlation and risk prediction. Tracking correlations were computed by race and gender, and were approximately 0.6 for systolic, 0.5-0.6 for K4 diastolic, and 0.4-0.6 for K5 diastolic blood pressure. The AUC can also be used to regress young adult blood pressure on childhood blood pressure and childhood and young adult body mass index (BMI). In these data, while childhood blood pressure and young adult BMI were generally directly predictive of young adult blood pressure, childhood BMI was negatively correlated with young adult blood pressure when childhood blood pressure was in the model. In addition, racial differences in young adult blood pressure were reduced, but not eliminated, after controlling for childhood blood pressure, childhood BMI, and young adult BMI, suggesting that other genetic or lifestyle factors contribute to this difference. 2004 John Wiley & Sons, Ltd.

  2. Pressure field in measurement section of wind tunnel

    Directory of Open Access Journals (Sweden)

    Hnidka Jakub

    2017-01-01

    Full Text Available The University of Defence in Brno has a new low-speed wind tunnel. In order to confirm the quality of the wind inside of the measurement section, several measurements of the dynamic pressure have been performed with the Pitot-static tube. The pressure fields are then analysed and quality of the field is evaluated. Measurement of a pressure drop on the body of a standing helicopter was conducted.

  3. The nuclear physical method for high pressure steam manifold water level gauging and its error

    International Nuclear Information System (INIS)

    Li Nianzu; Li Beicheng; Jia Shengming

    1993-10-01

    A new method, which is non-contact on measured water level, for measuring high pressure steam manifold water level with nuclear detection technique is introduced. This method overcomes the inherent drawback of previous water level gauges based on other principles. This method can realize full range real time monitoring on the continuous water level of high pressure steam manifold from the start to full load of boiler, and the actual value of water level can be obtained. The measuring errors were analysed on site. Errors from practical operation in Tianjin Junliangcheng Power Plant and in laboratory are also presented

  4. Size distributions of micro-bubbles generated by a pressurized dissolution method

    Science.gov (United States)

    Taya, C.; Maeda, Y.; Hosokawa, S.; Tomiyama, A.; Ito, Y.

    2012-03-01

    Size of micro-bubbles is widely distributed in the range of one to several hundreds micrometers and depends on generation methods, flow conditions and elapsed times after the bubble generation. Although a size distribution of micro-bubbles should be taken into account to improve accuracy in numerical simulations of flows with micro-bubbles, a variety of the size distribution makes it difficult to introduce the size distribution in the simulations. On the other hand, several models such as the Rosin-Rammler equation and the Nukiyama-Tanazawa equation have been proposed to represent the size distribution of particles or droplets. Applicability of these models to the size distribution of micro-bubbles has not been examined yet. In this study, we therefore measure size distribution of micro-bubbles generated by a pressurized dissolution method by using a phase Doppler anemometry (PDA), and investigate the applicability of the available models to the size distributions of micro-bubbles. Experimental apparatus consists of a pressurized tank in which air is dissolved in liquid under high pressure condition, a decompression nozzle in which micro-bubbles are generated due to pressure reduction, a rectangular duct and an upper tank. Experiments are conducted for several liquid volumetric fluxes in the decompression nozzle. Measurements are carried out at the downstream region of the decompression nozzle and in the upper tank. The experimental results indicate that (1) the Nukiyama-Tanasawa equation well represents the size distribution of micro-bubbles generated by the pressurized dissolution method, whereas the Rosin-Rammler equation fails in the representation, (2) the bubble size distribution of micro-bubbles can be evaluated by using the Nukiyama-Tanasawa equation without individual bubble diameters, when mean bubble diameter and skewness of the bubble distribution are given, and (3) an evaluation method of visibility based on the bubble size distribution and bubble

  5. Various high precision measurements of pressure in atomic energy industry

    International Nuclear Information System (INIS)

    Aritomi, Masanori; Inoue, Akira; Hosoma, Takashi; Tanaka, Izumi; Gabane, Tsunemichi.

    1987-01-01

    As for the pressure measurement in atomic energy industry, it is mostly the measurement using differential pressure transmitters and pressure transmitters for process measurement with the general accuracy of measurement of 0.2 - 0.5 % FS/year. However, recently for the development of nuclear fusion reactors and the establishment of nuclear fuel cycle accompanying new atomic energy technology, there are the needs of the pressure measurement having higher accuracy of 0.01 % FS/year and high resolution, and quartz vibration type pressure sensors appeared. New high accuracy pressure measurement techniques were developed by the advance of data processing and the rationalization of data transmission. As the results, the measurement of the differential pressure of helium-lithium two-phase flow in the cooling system of nuclear fusion reactors, the high accuracy measuring system for the level of plutonium nitrate and other fuel substance in tanks in fuel reprocessing and conversion, the high accuracy measurement of atmospheric pressure and wind velocity in ducts, chimneys and tunnels in nuclear facilities and so on became feasible. The principle and the measured data of quartz vibration type pressure sensors are shown. (Kako, I.)

  6. Method for the measurement of susceptibility to decubitus ulcer formation.

    Science.gov (United States)

    Meijer, J H; Schut, G L; Ribbe, M W; Goovaerts, H G; Nieuwenhuys, R; Reulen, J P; Schneider, H

    1989-09-01

    A method for measuring the susceptibility of a patient to develop decubitus ulcers is described and initially evaluated. It is based on an indirect, noninvasive measurement of the transient regional blood flow response after a test pressure load which simulates the external stimulus for pressure-sore formation. This method was developed to determine the individual risk of a patient and to study the subfactors which contribute to the susceptibility. This would also offer the possibility of evaluating the effect of preventive treatment aimed at reducing the susceptibility. The method was found to discriminate between preselected elderly patients at risk on the one hand, and non-risk patients and healthy young adults on the other hand. No differences in blood flow responses were found between the non-risk elderly patients and the healthy young adults. This suggests that age per se is not a factor in the formation of pressure sores. In the risk group the recovery time after pressure relief was found to be three times as long as the duration of the pressure exercise. This indicates that the recovery time after pressure exercise may be as important as the period of pressure exercise in deducing the risk of developing decubitus ulcers.

  7. TMX-U neutral pressure measurement diagnostic systems

    International Nuclear Information System (INIS)

    Pickles, W.L.; Allen, S.L.; Hill, D.N.; Hunt, A.L.; Simonen, T.C.

    1984-01-01

    The Tandem Mirror Experiment-Upgrade (TMX-U) has a large and complex system of Baird Alpert, magnetron, and Penning gauges, in addition to mass spectrometers (RGA), all of which measure neutral pressures in the many internal regions of TMX-U. These pressure measurements are used as part of the confinement physics data base as well as for management of the TMX-U vacuum system. Dynamic pressures are modeled by a coupled-volumes simulation code, which includes wall reflus, getter pumping, and plasma pumping

  8. Heat pump control method based on direct measurement of evaporation pressure to improve energy efficiency and indoor air temperature stability at a low cooling load condition

    International Nuclear Information System (INIS)

    Park, Young Sung; Jeong, Ji Hwan; Ahn, Byoung Ha

    2014-01-01

    Highlights: • New heat pump control method was developed. • Experimental investigation on performance of heat pump with various control method. • New control method appeared to improve the stability of indoor air temperature. • New control method appeared to have a potential to reduce power consumption. - Abstract: The control systems of conventional heat pumps have an input of refrigerant temperature at the evaporator outlet to maintain superheat at proper level. In order to develop a control method that can be used to achieve better indoor thermal comfort and energy efficiency at a low cooling load condition than the current control method, a new method of the evaporation pressure control based on the evaporator outlet pressure reading (EPCP) was developed. The changes in the stability of indoor air temperature and power consumption were measured while changing the compressor frequency in accordance with the new control method. Compared with the evaporation pressure control based on the evaporator outlet temperature reading, the EPCP control method appeared to improve the stability of room air temperature or occupant thermal comfort significantly

  9. Pirani pressure sensor with distributed temperature measurement

    NARCIS (Netherlands)

    de Jong, B.R.; Bula, W.P.; Zalewski, D.R.; van Baar, J.J.J.; Wiegerink, Remco J.

    2003-01-01

    Surface micro-machined distributed Pirani pressure gauges, with designed heater-to-heat sink distances (gap-heights) of 0.35 μm and 1.10 μm, are successfully fabricated, modeled and characterized. Measurements and model response correspond within 5% of the measured value in a pressure range of 10 to

  10. Method for verifying the pressure in a nuclear reactor fuel rod

    International Nuclear Information System (INIS)

    Jones, W.J.

    1979-01-01

    Disclosed is a method of accurately verifying the pressure contained in a sealed pressurized fuel rod by utilizing a pressure balance measurement technique wherein an end of the fuel rod extends through and is sealed in a wall of a small chamber. The chamber is pressurized to the nominal (desired) fuel rod pressure and the fuel rod is then pierced to interconnect the chamber and fuel rod. The deviation of chamber pressure is noted. The final combined pressure of the fuel rod and drill chamber is substantially equal to the nominal rod pressure; departure of the combined pressure from nominal is in direct proportion to departure of rod pressure from nominal. The maximum error in computing the rod pressure from the deviation of the combined pressure from nominal is estimated at plus or minus 3.0 psig for rod pressures within the specified production limits. If the rod pressure is corrected for rod void volume using a digital printer data record, the accuracy improves to about plus or minus 2.0 psig

  11. Near-field acoustic holography with sound pressure and particle velocity measurements

    DEFF Research Database (Denmark)

    Fernandez Grande, Efren

    of the particle velocity has notable potential in NAH, and furthermore, combined measurement of sound pressure and particle velocity opens a new range of possibilities that are examined in this study. On this basis, sound field separation methods have been studied, and a new measurement principle based on double...... layer measurements of the particle velocity has been proposed. Also, the relation between near-field and far-field radiation from sound sources has been examined using the concept of the supersonic intensity. The calculation of this quantity has been extended to other holographic methods, and studied...

  12. Hybrid Optical Unobtrusive Blood Pressure Measurements

    Directory of Open Access Journals (Sweden)

    Guangfei Zhang

    2017-07-01

    Full Text Available Blood pressure (BP is critical in diagnosing certain cardiovascular diseases such as hypertension. Some previous studies have proved that BP can be estimated by pulse transit time (PTT calculated by a pair of photoplethysmography (PPG signals at two body sites. Currently, contact PPG (cPPG and imaging PPG (iPPG are two feasible ways to obtain PPG signals. In this study, we proposed a hybrid system (called the ICPPG system employing both methods that can be implemented on a wearable device, facilitating the measurement of BP in an inconspicuous way. The feasibility of the ICPPG system was validated on a dataset with 29 subjects. It has been proved that the ICPPG system is able to estimate PTT values. Moreover, the PTT measured by the new system shows a correlation on average with BP variations for most subjects, which could facilitate a new generation of BP measurement using wearable and mobile devices.

  13. Using pressure square-like wave to measure the dynamic characteristics of piezoelectric pressure sensor

    International Nuclear Information System (INIS)

    Han, L-L; Tsung, T-T; Chen, L-C; Chang Ho; Jwo, C-S

    2005-01-01

    Piezoelectric pressure sensors are commonly used to measuring the dynamic characteristics in a hydraulic system. The dynamic measurements require a pressure sensor which has a high response rate. In this paper, we proposed use of a pressure square wave to excite the piezoelectric pressure sensor. Experimental frequencies are 0.5, 1.0, 1.5, and 2.0 kHz at 10, 15, 20 bar, respectively. Results show that the waveform of time-domain and frequencydomain response are quite different under above testing conditions. The higher the frequencies tested, the faster the pressure-rise speeds obtained. Similarly, the higher the testing pressure, the shorter the rise time attained

  14. Industrial flow measurement, with particular emphasis on new methods. 2. rev. ed.

    International Nuclear Information System (INIS)

    Bonfig, K.W.

    1987-01-01

    The book reviews in detail the various methods of flow measurement, their basic principles and characteristic features, fields of application, and error sources. An account is given of the state of the art of the different flow measuring techniques currently available, as e.g.: Volumetric flow measurement, pressure-dependent measuring techniques, tracer methods, techniques using the pressure drop, difference in height, magnetic induction, or temperature fluctuations; ultrasonic flow, mass flow, vortex shedding and swirlmeters, oscillatory flow measurement, corona anemometers, velocity measurement using laser beams, or nuclear resonance. (DG) [de

  15. Full scale measurement of wind induced pressures : 1 configuration of wind induced pressures

    NARCIS (Netherlands)

    Geurts, C.P.W.; Wijen, H.L.M.

    1994-01-01

    A research project 10 the spectral characteristics of wind induced pressures is in progress in Eindhoven. This project includes both wind tunnel and full scale measurements. Wind induced pressures are measured in full scale at the main building of Eindhoven University of Technology. This paper

  16. Blood pressure measurement: one arm or both arm?

    Science.gov (United States)

    Kulkarni, Prasad K; Shekhar, Susheela; Reddy, B N; Nirmala, B C

    2011-09-01

    Guidelines for measuring blood pressure includes measurement of blood pressure on both arms but it is often ignored. Our case report aims at highlighting the need follow the guidelines. A 60 year old 59 kg weighing male asymptomatic patient without any comobidities was posted for bilateral inguinal hernia repair. The interarm blood pressure difference was discovered incidentally during his preanaesthetic evalution. On further evaluation patient was found to be having subclavian stenosis on left side which was asymptomatic. Intraoperative and post operative period was uneventful. Blood pressure measurement should be done in accordance with the stipulated guidelines. Inter arm blood pressure difference should be noted in all patients as not only for diagnosis and treatment of hypertension but also as a tool to diagnose asymptomatic peripheral vascular disesase.

  17. Nonlinear parameter (B/A) measurements in methanol, 1-butanol and 1-octanol for different pressures and temperatures

    International Nuclear Information System (INIS)

    Plantier, F.; Daridon, J.L.; Lagourette, B.

    2002-01-01

    Experimental determinations versus pressure of the nonlinear acoustic parameter B/A have been conducted for methanol, 1-butanol and 1-octanol in the pressure range 0-50 MPa and temperature range 303.15-373.15 K. These measurements proceed from an experimental technique based on a phase comparison method allowing to measure the change in sound speed with the pressure for an isentropic process. The value of B/A is found to decrease with increasing pressure and seems to be an increasing function of temperature. A comparison with the data determined numerically by the classical thermodynamic method has also been performed. (author)

  18. Wavenumber-frequency Spectra of Pressure Fluctuations Measured via Fast Response Pressure Sensitive Paint

    Science.gov (United States)

    Panda, J.; Roozeboom, N. H.; Ross, J. C.

    2016-01-01

    The recent advancement in fast-response Pressure-Sensitive Paint (PSP) allows time-resolved measurements of unsteady pressure fluctuations from a dense grid of spatial points on a wind tunnel model. This capability allows for direct calculations of the wavenumber-frequency (k-?) spectrum of pressure fluctuations. Such data, useful for the vibro-acoustics analysis of aerospace vehicles, are difficult to obtain otherwise. For the present work, time histories of pressure fluctuations on a flat plate subjected to vortex shedding from a rectangular bluff-body were measured using PSP. The light intensity levels in the photographic images were then converted to instantaneous pressure histories by applying calibration constants, which were calculated from a few dynamic pressure sensors placed at selective points on the plate. Fourier transform of the time-histories from a large number of spatial points provided k-? spectra for pressure fluctuations. The data provides first glimpse into the possibility of creating detailed forcing functions for vibro-acoustics analysis of aerospace vehicles, albeit for a limited frequency range.

  19. Use of an Ethanol-Driven Pressure Cell to Measure Hydrostatic Pressure Response of Protein-Stabilized Gold Nanoclusters

    Science.gov (United States)

    2016-01-01

    ARL-TR-7577 ● JAN 2016 US Army Research Laboratory Use of an Ethanol-Driven Pressure Cell to Measure Hydrostatic Pressure ...ARL-TR-7577 ● JAN 2016 US Army Research Laboratory Use of an Ethanol-Driven Pressure Cell to Measure Hydrostatic Pressure Response of...DATES COVERED (From - To) May 2014–September 2014 4. TITLE AND SUBTITLE Use of an Ethanol-Driven Pressure Cell to Measure Hydrostatic Pressure

  20. Serial blood pressure measurements

    Directory of Open Access Journals (Sweden)

    N.R. Koehler

    2002-05-01

    Full Text Available The objective of the present investigation was to study the effects of a 60-s interval of venous congestion between two noninvasive measurements of arterial blood pressure (ABP on the fluctuation of ABP, assessed by the standard deviation of the differences between two readings. ABP was measured in 345 successive patients, at rest, four times each. For 269 participants, one pair of readings was obtained with a 60-s interval and the other pair without an interval. For 76 patients, the first pair was read at the same interval, and the second pair had venous congestion interposed and there was no waiting interval. There was no increased ABP oscillation, either when there was no interval between ABP readings, or when venous congestion was interposed compared to pairs of ABP measurements performed with a 60-s interval. There was no increase in ABP oscillations when successive ABP readings were taken without an interval or even with venous congestion interposed. Contrary to the present belief, there seems to be no loss of reliability when blood pressure recordings are taken immediately one after another, in the clinical setting.

  1. Arterial blood pressure measurement and pulse wave analysis—their role in enhancing cardiovascular assessment

    International Nuclear Information System (INIS)

    Avolio, Alberto P; Butlin, Mark; Walsh, Andrew

    2010-01-01

    The most common method of clinical measurement of arterial blood pressure is by means of the cuff sphygmomanometer. This instrument has provided fundamental quantitative information on arterial pressure in individual subjects and in populations and facilitated estimation of cardiovascular risk related to levels of blood pressure obtained from the brachial cuff. Although the measurement is taken in a peripheral limb, the values are generally assumed to reflect the pressure throughout the arterial tree in large conduit arteries. Since the arterial pressure pulse becomes modified as it travels away from the heart towards the periphery, this is generally true for mean and diastolic pressure, but not for systolic pressure, and so pulse pressure. The relationship between central and peripheral pulse pressure depends on propagation characteristics of arteries. Hence, while the sphygmomanometer gives values of two single points on the pressure wave (systolic and diastolic pressure), there is additional information that can be obtained from the time-varying pulse waveform that enables an improved quantification of the systolic load on the heart and other central organs. This topical review will assess techniques of pressure measurement that relate to the use of the cuff sphygmomanometer and to the non-invasive registration and analysis of the peripheral and central arterial pressure waveform. Improved assessment of cardiovascular function in relation to treatment and management of high blood pressure will result from future developments in the indirect measurement of arterial blood pressure that involve the conventional cuff sphygmomanometer with the addition of information derived from the peripheral arterial pulse. (topical review)

  2. Apparatus and method for non-contact, acoustic resonance determination of intraocular pressure

    Science.gov (United States)

    Sinha, D.N.; Wray, W.O.

    1994-12-27

    The apparatus and method for measuring intraocular pressure changes in an eye under investigation by detection of vibrational resonances therein. An ultrasonic transducer operating at its resonant frequency is amplitude modulated and swept over a range of audio frequencies in which human eyes will resonate. The output therefrom is focused onto the eye under investigation, and the resonant vibrations of the eye observed using a fiber-optic reflection vibration sensor. Since the resonant frequency of the eye is dependent on the pressure therein, changes in intraocular pressure may readily be determined after a baseline pressure is established. 3 figures.

  3. Method of measuring density of gas in a vessel

    International Nuclear Information System (INIS)

    Shono, Kosuke.

    1981-01-01

    Purpose: To accurately measure the density of a gas in a vessel even at a loss-of-coolant accident in a BWR type reactor. Method: When at least one of the pressure or the temperature of gas in a vessel exceeds the usable range of a gas density measuring instrument due to a loss-of-coolant accident, the gas in the vessel is sampled, and the pressure or the temperature of the sampled gas are measured by matching them to the usable conditions of the gas density measuring instrument. Hydrogen gas and oxygen gas densities exceeding the usable range of the gas density measuring instrument are calculated by the following formulae based on the measured values. C'sub(O) = P sub(T).C sub(O)/P sub(T), C'sub(H) = C''sub(H).C'sub(O)/C''sub(O), where C sub(O), P sub(T), C'sub(H) represent the oxygen density, the total pressure and the hydrogen density of the internal pressure gas of the vessel after the respective gas density measuring instruments exceed the usable ranges; C sub(O), P sub(T) represent the oxygen density and the total pressure of the gas in the vessel before the gas density measuring instruments exceeded the usable range, and C''sub(H), C''sub(O) represent the hydrogen density and oxygen density of the respective sampled gases. (Kamimura, M.)

  4. A Newly Designed Fiber-Optic Based Earth Pressure Transducer with Adjustable Measurement Range

    Directory of Open Access Journals (Sweden)

    Hou-Zhen Wei

    2018-03-01

    Full Text Available A novel fiber-optic based earth pressure sensor (FPS with an adjustable measurement range and high sensitivity is developed to measure earth pressures for civil infrastructures. The new FPS combines a cantilever beam with fiber Bragg grating (FBG sensors and a flexible membrane. Compared with a traditional pressure transducer with a dual diaphragm design, the proposed FPS has a larger measurement range and shows high accuracy. The working principles, parameter design, fabrication methods, and laboratory calibration tests are explained in this paper. A theoretical solution is derived to obtain the relationship between the applied pressure and strain of the FBG sensors. In addition, a finite element model is established to analyze the mechanical behavior of the membrane and the cantilever beam and thereby obtain optimal parameters. The cantilever beam is 40 mm long, 15 mm wide, and 1 mm thick. The whole FPS has a diameter of 100 mm and a thickness of 30 mm. The sensitivity of the FPS is 0.104 kPa/με. In addition, automatic temperature compensation can be achieved. The FPS’s sensitivity, physical properties, and response to applied pressure are extensively examined through modeling and experiments. The results show that the proposed FPS has numerous potential applications in soil pressure measurement.

  5. Association between routine and standardized blood pressure measurements and left ventricular hypertrophy among patients on hemodialysis.

    Science.gov (United States)

    Khangura, Jaspreet; Culleton, Bruce F; Manns, Braden J; Zhang, Jianguo; Barnieh, Lianne; Walsh, Michael; Klarenbach, Scott W; Tonelli, Marcello; Sarna, Magdalena; Hemmelgarn, Brenda R

    2010-06-24

    Left ventricular (LV) hypertrophy is common among patients on hemodialysis. While a relationship between blood pressure (BP) and LV hypertrophy has been established, it is unclear which BP measurement method is the strongest correlate of LV hypertrophy. We sought to determine agreement between various blood pressure measurement methods, as well as identify which method was the strongest correlate of LV hypertrophy among patients on hemodialysis. This was a post-hoc analysis of data from a randomized controlled trial. We evaluated the agreement between seven BP measurement methods: standardized measurement at baseline; single pre- and post-dialysis, as well as mean intra-dialytic measurement at baseline; and cumulative pre-, intra- and post-dialysis readings (an average of 12 monthly readings based on a single day per month). Agreement was assessed using Lin's concordance correlation coefficient (CCC) and the Bland Altman method. Association between BP measurement method and LV hypertrophy on baseline cardiac MRI was determined using receiver operating characteristic curves and area under the curve (AUC). Agreement between BP measurement methods in the 39 patients on hemodialysis varied considerably, from a CCC of 0.35 to 0.94, with overlapping 95% confidence intervals. Pre-dialysis measurements were the weakest predictors of LV hypertrophy while standardized, post- and inter-dialytic measurements had similar and strong (AUC 0.79 to 0.80) predictive power for LV hypertrophy. A single standardized BP has strong predictive power for LV hypertrophy and performs just as well as more resource intensive cumulative measurements, whereas pre-dialysis blood pressure measurements have the weakest predictive power for LV hypertrophy. Current guidelines, which recommend using pre-dialysis measurements, should be revisited to confirm these results.

  6. The Effect of Various Contact Lenses on Intraocular Pressure Measurement by Goldman Tonometer

    Directory of Open Access Journals (Sweden)

    Monireh Mahjoob

    2014-06-01

    Full Text Available Background: Today, contact lenses have extensive usages. Contact lens places on cornea, so it may induce variation on cornea and these variations can influence the measurement of intraocular pressure (IOP by Goldman tonometer. The aim of this research was to study the effect of various contact lenses on measurement of intraocular pressure by Goldman tonometer. Materials and Methods: In this study, 80 subjects aged 18-25 were selected randomly among patients of Al-Zahra ophthalmology center. None of them has any eye pathological problems. Before wearing the lens, intraocular pressure was measured, and then patients were divided into two groups of soft and hard contact lenses. Soft and hard contact lenses were placed on the eye for two hours, and the intraocular pressure was measured again. Results: The mean of IOP before wearing contact lenses and two hours later was 15.96 mmHg and 13.93, s respectively. Paired test showed a significant difference between IOP before and after wearing contact lenses (p=0.001.There was no significant differences in mean of intraocular pressure decline before and after placing the contact lens in both soft and hard lenses. Conclusion: According to this study, the intraocular pressure decreases after wearing contact lenses (CL. This decline may be due to variation in properties of cornea after wearing CL that can also affect IOP measurement.

  7. Adaptive control with self-tuning for non-invasive beat-by-beat blood pressure measurement.

    Science.gov (United States)

    Nogawa, Masamichi; Ogawa, Mitsuhiro; Yamakoshi, Takehiro; Tanaka, Shinobu; Yamakoshi, Ken-ichi

    2011-01-01

    Up to now, we have successfully carried out the non-invasive beat-by-beat measurement of blood pressure (BP) in the root of finger, superficial temporal and radial artery based on the volume-compensation technique with reasonable accuracy. The present study concerns with improvement of control method for this beat-by-beat BP measurement. The measurement system mainly consists of a partial pressurization cuff with a pair of LED and photo-diode for the detection of arterial blood volume, and a digital self-tuning control method. Using healthy subjects, the performance and accuracy of this system were evaluated through comparison experiments with the system using a conventional empirically tuned PID controller. The significant differences of BP measured in finger artery were not showed in systolic (SBP), p=0.52, and diastolic BP (DBP), p=0.35. With the advantage of the adaptive control with self-tuning method, which can tune the control parameters without disturbing the control system, the application area of the non-invasive beat-by-beat measurement method will be broadened.

  8. Measurement Uncertainty of Dew-Point Temperature in a Two-Pressure Humidity Generator

    Science.gov (United States)

    Martins, L. Lages; Ribeiro, A. Silva; Alves e Sousa, J.; Forbes, Alistair B.

    2012-09-01

    This article describes the measurement uncertainty evaluation of the dew-point temperature when using a two-pressure humidity generator as a reference standard. The estimation of the dew-point temperature involves the solution of a non-linear equation for which iterative solution techniques, such as the Newton-Raphson method, are required. Previous studies have already been carried out using the GUM method and the Monte Carlo method but have not discussed the impact of the approximate numerical method used to provide the temperature estimation. One of the aims of this article is to take this approximation into account. Following the guidelines presented in the GUM Supplement 1, two alternative approaches can be developed: the forward measurement uncertainty propagation by the Monte Carlo method when using the Newton-Raphson numerical procedure; and the inverse measurement uncertainty propagation by Bayesian inference, based on prior available information regarding the usual dispersion of values obtained by the calibration process. The measurement uncertainties obtained using these two methods can be compared with previous results. Other relevant issues concerning this research are the broad application to measurements that require hygrometric conditions obtained from two-pressure humidity generators and, also, the ability to provide a solution that can be applied to similar iterative models. The research also studied the factors influencing both the use of the Monte Carlo method (such as the seed value and the convergence parameter) and the inverse uncertainty propagation using Bayesian inference (such as the pre-assigned tolerance, prior estimate, and standard deviation) in terms of their accuracy and adequacy.

  9. A novel high pressure, high temperature vessel used to conduct long-term stability measurements of silicon MEMS pressure transducers

    Science.gov (United States)

    Wisniewiski, David

    2014-03-01

    The need to quantify and to improve long-term stability of pressure transducers is a persistent requirement from the aerospace sector. Specifically, the incorporation of real-time pressure monitoring in aircraft landing gear, as exemplified in Tire Pressure Monitoring Systems (TPMS), has placed greater demand on the pressure transducer for improved performance and increased reliability which is manifested in low lifecycle cost and minimal maintenance downtime through fuel savings and increased life of the tire. Piezoresistive (PR) silicon MEMS pressure transducers are the primary choice as a transduction method for this measurement owing to their ability to be designed for the harsh environment seen in aircraft landing gear. However, these pressure transducers are only as valuable as the long-term stability they possess to ensure reliable, real-time monitoring over tens of years. The "heart" of the pressure transducer is the silicon MEMS element, and it is at this basic level where the long-term stability is established and needs to be quantified. A novel High Pressure, High Temperature (HPHT) vessel has been designed and constructed to facilitate this critical measurement of the silicon MEMS element directly through a process of mechanically "floating" the silicon MEMS element while being subjected to the extreme environments of pressure and temperature, simultaneously. Furthermore, the HPHT vessel is scalable to permit up to fifty specimens to be tested at one time to provide a statistically significant data population on which to draw reasonable conclusions on long-term stability. With the knowledge gained on the silicon MEMS element, higher level assembly to the pressure transducer envelope package can also be quantified as to the build-effects contribution to long-term stability in the same HPHT vessel due to its accommodating size. Accordingly, a HPHT vessel offering multiple levels of configurability and robustness in data measurement is presented, along

  10. Experimental Pressure Measurements on Hydropower Turbine Runners

    Energy Technology Data Exchange (ETDEWEB)

    Harding, Samuel F.; Richmond, Marshall C.

    2017-04-28

    The range of hydrodynamic operating conditions to which the turbine is exposed results in significant pressure fluctuations on both the pressure and suction sides of the blades. Understanding these dynamic pressures has a range of applications. Structurally, the resulting dynamic loads are significant in understanding the design life and maintenance schedule of the bearing, shafts and runner components. The pulsing pressures have also been seen to have a detrimental effect on the surface condition of the blades. Biologically, the pressure gradients and pressure extremes are the primary driver of barotrauma for fish passing through hydroturbines. Improvements in computational fluid dynamics (CFD) can be used to simulate such unsteady pressures in the regions of concern. High frequency model scale and prototype measurements of pressures at the blade are important in the validation of these models. Experimental characterization of pressure fields over hydroturbine blades has been demonstrated by a number of studies which using multiple pressure transducers to map the pressure contours on the runner blades. These have been performed at both model and prototype scales, often to validate computational models of the pressure and flow fields over the blades. This report provides a review of existing studies in which the blade pressure was measured in situ. The report assesses the technology for both model and prototype scale testing. The details of the primary studies in this field are reported and used to inform the types of hardware required for similar experiments based on the Ice Harbor Dam owned by the US Corps of Engineers on the Snake River, WA, USA. Such a study would be used to validate the CFD performed for the BioPA.

  11. Pressure Autoregulation Measurement Techniques in Adult Traumatic Brain Injury, Part I: A Scoping Review of Intermittent/Semi-Intermittent Methods.

    Science.gov (United States)

    Zeiler, Frederick A; Donnelly, Joseph; Calviello, Leanne; Menon, David K; Smielewski, Peter; Czosnyka, Marek

    2017-12-01

    The purpose of this study was to perform a systematic, scoping review of commonly described intermittent/semi-intermittent autoregulation measurement techniques in adult traumatic brain injury (TBI). Nine separate systematic reviews were conducted for each intermittent technique: computed tomographic perfusion (CTP)/Xenon-CT (Xe-CT), positron emission tomography (PET), magnetic resonance imaging (MRI), arteriovenous difference in oxygen (AVDO 2 ) technique, thigh cuff deflation technique (TCDT), transient hyperemic response test (THRT), orthostatic hypotension test (OHT), mean flow index (Mx), and transfer function autoregulation index (TF-ARI). MEDLINE ® , BIOSIS, EMBASE, Global Health, Scopus, Cochrane Library (inception to December 2016), and reference lists of relevant articles were searched. A two tier filter of references was conducted. The total number of articles utilizing each of the nine searched techniques for intermittent/semi-intermittent autoregulation techniques in adult TBI were: CTP/Xe-CT (10), PET (6), MRI (0), AVDO 2 (10), ARI-based TCDT (9), THRT (6), OHT (3), Mx (17), and TF-ARI (6). The premise behind all of the intermittent techniques is manipulation of systemic blood pressure/blood volume via either chemical (such as vasopressors) or mechanical (such as thigh cuffs or carotid compression) means. Exceptionally, Mx and TF-ARI are based on spontaneous fluctuations of cerebral perfusion pressure (CPP) or mean arterial pressure (MAP). The method for assessing the cerebral circulation during these manipulations varies, with both imaging-based techniques and TCD utilized. Despite the limited literature for intermittent/semi-intermittent techniques in adult TBI (minus Mx), it is important to acknowledge the availability of such tests. They have provided fundamental insight into human autoregulatory capacity, leading to the development of continuous and more commonly applied techniques in the intensive care unit (ICU). Numerous methods of

  12. In-situ measurement of response time of RTDs and pressure transmitters in nuclear power plants

    International Nuclear Information System (INIS)

    Hashemian, H.M.; Riner, J.L.

    1993-01-01

    Response time measurements are performed once every fuel cycle on most safety-related temperature and pressure sensors in a majority of nuclear power plants in the US. This paper provides a review of the methods that are used for these measurements. The methods are referred to as the Loop Current Step Response (LCSR) test, which is used for response time testing of temperature sensors, and noise analysis and power interrupt (PI) tests, which are used for response time testing of pressure, level, and flow transmitters

  13. Association between routine and standardized blood pressure measurements and left ventricular hypertrophy among patients on hemodialysis

    Directory of Open Access Journals (Sweden)

    Walsh Michael

    2010-06-01

    Full Text Available Abstract Background Left ventricular (LV hypertrophy is common among patients on hemodialysis. While a relationship between blood pressure (BP and LV hypertrophy has been established, it is unclear which BP measurement method is the strongest correlate of LV hypertrophy. We sought to determine agreement between various blood pressure measurement methods, as well as identify which method was the strongest correlate of LV hypertrophy among patients on hemodialysis. Methods This was a post-hoc analysis of data from a randomized controlled trial. We evaluated the agreement between seven BP measurement methods: standardized measurement at baseline; single pre- and post-dialysis, as well as mean intra-dialytic measurement at baseline; and cumulative pre-, intra- and post-dialysis readings (an average of 12 monthly readings based on a single day per month. Agreement was assessed using Lin's concordance correlation coefficient (CCC and the Bland Altman method. Association between BP measurement method and LV hypertrophy on baseline cardiac MRI was determined using receiver operating characteristic curves and area under the curve (AUC. Results Agreement between BP measurement methods in the 39 patients on hemodialysis varied considerably, from a CCC of 0.35 to 0.94, with overlapping 95% confidence intervals. Pre-dialysis measurements were the weakest predictors of LV hypertrophy while standardized, post- and inter-dialytic measurements had similar and strong (AUC 0.79 to 0.80 predictive power for LV hypertrophy. Conclusions A single standardized BP has strong predictive power for LV hypertrophy and performs just as well as more resource intensive cumulative measurements, whereas pre-dialysis blood pressure measurements have the weakest predictive power for LV hypertrophy. Current guidelines, which recommend using pre-dialysis measurements, should be revisited to confirm these results.

  14. An investigation of methods for free-field comparison calibration of measurement microphones

    DEFF Research Database (Denmark)

    Barrera-Figueroa, Salvador; Moreno Pescador, Guillermo; Jacobsen, Finn

    2010-01-01

    Free-field comparison calibration of measurement microphones requires that a calibrated reference microphone and a test microphone are exposed to the same sound pressure in a free field. The output voltages of the microphones can be measured either sequentially or simultaneously. The sequential...... method requires the sound field to have good temporal stability. The simultaneous method requires instead that the sound pressure is the same in the positions where the microphones are placed. In this paper the results of the application of the two methods are compared. A third combined method...

  15. Difference in blood pressure measurements between arms: methodological and clinical implications.

    Science.gov (United States)

    Clark, Christopher E

    2015-01-01

    Differences in blood pressure measurements between arms are commonly encountered in clinical practice. If such differences are not excluded they can delay the diagnosis of hypertension and can lead to poorer control of blood pressure levels. Differences in blood pressure measurements between arms are associated cross sectionally with other signs of vascular disease such as peripheral arterial disease or cerebrovascular disease. Differences are also associated prospectively with increased cardiovascular mortality and morbidity and all cause mortality. Numbers of publications on inter-arm difference are rising year on year, indicating a growing interest in the phenomenon. The prevalence of an inter-arm difference varies widely between reports, and is correlated with the underlying cardiovascular risk of the population studied. Prevalence is also sensitive to the method of measurement used. This review discusses the prevalence of an inter-arm difference in different populations and addresses current best practice for the detection and the measurement of a difference. The evidence for clinical and for vascular associations of an inter-arm difference is presented in considering the emerging role of an inter-arm blood pressure difference as a novel risk factor for increased cardiovascular morbidity and mortality. Competing aetiological explanations for an inter-arm difference are explored, and gaps in our current understanding of this sign, along with areas in need of further research, are considered.

  16. An investigation of temperature measurement methods in nuclear power plant reactor pressure vessel annealing

    International Nuclear Information System (INIS)

    Acton, R.U.; Gill, W.; Sais, D.J.; Schulze, D.H.; Nakos, J.T.

    1996-05-01

    The objective of this project was to provide an assessment of several methods by which the temperature of a commercial nuclear power plant reactor pressure vessel (RPV) could be measured during an annealing process. This project was a coordinated effort between DOE's Office of Nuclear Energy, Science and Technology; DOE's Light Water Reactor Technology Center at Sandia National Laboratories; and the Electric Power Research Institute's Non- Destructive Evaluation Center. Ball- thermocouple probes similar to those described in NUREG/CR-5760, spring-loaded, metal- sheathed thermocouple probes, and 1778 air- suspended thermocouples were investigated in experiments that heated a section of an RPV wall to simulate a thermal annealing treatment. A parametric study of ball material, emissivity, thermal conductivity, and thermocouple function locations was conducted. Also investigated was a sheathed thermocouple failure mode known as shunting (electrical breakdown of insulation separating the thermocouple wires). Large errors were found between the temperature as measured by the probes and the true RPV wall temperature during heat-up and cool-down. At the annealing soak temperature, in this case 454 degrees C [850'F], all sensors measured the same temperature within about ±5% (23.6 degrees C [42.5 degrees F]). Because of these errors, actual RPV wall heating and cooling rates differed from those prescribed (by up to 29%). Shunting does not appear to be a problem under these conditions. The large temperature measurement errors led to the development of a thermal model that predicts the RPV wall temperature from the temperature of a ball- probe. Comparisons between the model and the experimental data for ball-probes indicate that the model could be a useful tool in predicting the actual RPV temperature based on the indicated ball- probe temperature. The model does not predict the temperature as well for the spring-loaded and air suspended probes

  17. Vapor pressure measured with inflatable plastic bag

    Science.gov (United States)

    1965-01-01

    Deflated plastic bag in a vacuum chamber measures initial low vapor pressures of materials. The bag captures the test sample vapors and visual observation of the vapor-inflated bag under increasing external pressures yields pertinent data.

  18. Measurement of Vehicle-Bridge-Interaction force using dynamic tire pressure monitoring

    Science.gov (United States)

    Chen, Zhao; Xie, Zhipeng; Zhang, Jian

    2018-05-01

    The Vehicle-Bridge-Interaction (VBI) force, i.e., the normal contact force of a tire, is a key component in the VBI mechanism. The VBI force measurement can facilitate experimental studies of the VBI as well as input-output bridge structural identification. This paper introduces an innovative method for calculating the interaction force by using dynamic tire pressure monitoring. The core idea of the proposed method combines the ideal gas law and a basic force model to build a relationship between the tire pressure and the VBI force. Then, unknown model parameters are identified by the Extended Kalman Filter using calibration data. A signal filter based on the wavelet analysis is applied to preprocess the effect that the tire rotation has on the pressure data. Two laboratory tests were conducted to check the proposed method's validity. The effects of different road irregularities, loads and forward velocities were studied. Under the current experiment setting, the proposed method was robust to different road irregularities, and the increase in load and velocity benefited the performance of the proposed method. A high-speed test further supported the use of this method in rapid bridge tests. Limitations of the derived theories and experiment were also discussed.

  19. A human cadaver fascial compartment pressure measurement model.

    Science.gov (United States)

    Messina, Frank C; Cooper, Dylan; Huffman, Gretchen; Bartkus, Edward; Wilbur, Lee

    2013-10-01

    Fresh human cadavers provide an effective model for procedural training. Currently, there are no realistic models to teach fascial compartment pressure measurement. We created a human cadaver fascial compartment pressure measurement model and studied its feasibility with a pre-post design. Three faculty members, following instructions from a common procedure textbook, used a standard handheld intra-compartment pressure monitor (Stryker(®), Kalamazoo, MI) to measure baseline pressures ("unembalmed") in the anterior, lateral, deep posterior, and superficial posterior compartments of the lower legs of a fresh human cadaver. The right femoral artery was then identified by superficial dissection, cannulated distally towards the lower leg, and connected to a standard embalming machine. After a 5-min infusion, the same three faculty members re-measured pressures ("embalmed") of the same compartments on the cannulated right leg. Unembalmed and embalmed readings for each compartment, and baseline readings for each leg, were compared using a two-sided paired t-test. The mean baseline compartment pressures did not differ between the right and left legs. Using the embalming machine, compartment pressure readings increased significantly over baseline for three of four fascial compartments; all in mm Hg (±SD): anterior from 40 (±9) to 143 (±44) (p = 0.08); lateral from 22 (±2.5) to 160 (±4.3) (p cadaver using a standard embalming machine. Set-up is minimal and the model can be incorporated into teaching curricula. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. Body mass index and blood pressure measurement during pregnancy.

    LENUS (Irish Health Repository)

    Hogan, Jennifer L

    2012-02-01

    OBJECTIVE: The accurate measurement of blood pressure requires the use of a large cuff in subjects with a high mid-arm circumference (MAC). This prospective study examined the need for a large cuff during pregnancy and its correlation with maternal obesity. METHODS: Maternal body mass index (BMI), fat mass, and MAC were measured. RESULTS: Of 179 women studied, 15.6% were obese. With a BMI of level 1 obesity, 44% needed a large cuff and with a BMI of level 2 obesity 100% needed a large cuff. CONCLUSION: All women booking for antenatal care should have their MAC measured to avoid the overdiagnosis of pregnancy hypertension.

  1. Development and optimization of a device for diferencial pressure measurement

    International Nuclear Information System (INIS)

    Santarine, G.A.

    1980-01-01

    The measurements of reduced values of diferencial pressure, are studied. Several situations are described where the diferencial pressure accurate measurement is necessary in routine works in the Thermohydraulic Laboratory, as well as, the major pressure measurement devices and their respective range are studied. The development of a device for diferencial pressure measurement followed by the design development of the calibration bench covering the foreseen range, start up tests realization, optimization, calibration, performance analysis and conclusions, is showed. (Author) [pt

  2. Comparison of invasive and oscillometric blood pressure measurement techniques in anesthetized camelids

    OpenAIRE

    Aarnes, Turi K.; Hubbell, John A.E.; Lerche, Phillip; Bednarski, Richard M.

    2012-01-01

    This study assessed the accuracy of the oscillometric method for arterial blood pressure (ABP) monitoring in anesthetized camelids. Twenty camelids were anesthetized and systolic ABP (SABP), mean ABP (MABP), and diastolic ABP (DABP) were measured directly and using the oscillometric method. The mean difference between SABP measurements was −9.9 ± 21.9 mmHg with a range of −76 to 54 mmHg, and the 95% limits of agreement (LOA) were −33 to 53 mmHg. The difference between DABP measurements was −1...

  3. Dew-point measurements at high water vapour pressure

    Science.gov (United States)

    Lomperski, S.; Dreier, J.

    1996-05-01

    A dew-point meter capable of measuring humidity at high vapour pressure and high temperature has been constructed and tested. Humidity measurements in pure steam were made over the temperature range 100 - 1500957-0233/7/5/003/img1C and a vapour pressure range of 1 - 4 bar. The dew-point meter performance was assessed by comparing measurements with a pressure transmitter and agreement between the two was within 0957-0233/7/5/003/img2% relative humidity. Humidity measurements in steam - air mixtures were also made and the dew-point meter readings were compared to those of a zirconia oxygen sensor. For these tests the dew-point meter readings were generally within 0957-0233/7/5/003/img2% relative humidity of the oxygen sensor measurements.

  4. Plasma assisted measurements of alkali metal concentrations in pressurized combustion processes

    International Nuclear Information System (INIS)

    Hernberg, R.; Haeyrinen, V.

    1995-01-01

    The plasma assisted method for continuous measurement of alkali metal concentrations in product gas flows of pressurized energy processes will be tested and applied at the 1.6 MW PFBC/G facility at Delft University of Technology in the Netherlands. Measurements will be performed during 1995 and 1996 at different stages of the research programme. The results are expected to give information about the influence of different process conditions on the generation of alkali metal vapours, the comparison of different methods for alkali measurement and the specific performance of our system. The project belongs to the Joule II extension program under contract JOU2-CT93-0431. (author)

  5. Method of measuring reactor water level

    International Nuclear Information System (INIS)

    Shinohara, Kaoru.

    1979-01-01

    Purpose: To provide a water level measuring system so that a reactor water level detecting signal can be corrected in correspondence to a recirculation flow, thereby to carry out a correct water level detection in a wide range of the reactor. Method: According to the operation record of a precursor reactor, the ratio Δh of the lowering of the water level due to the recirculation flow is lowered in proportion to the ratiowith respect to the rated differential pressure of the recirculation flow. Accordingly, the flow of recirculation pump is measured by an elbow differential pressure generator utilizing an elbow of a pipe, and the measured value is multiplied by a gain by a ratio setter, and therefter, an addition computation is carried out by an adder for correcting the signal from a water level detector. When the signal from the water level detector is corrected in this manner, the influence of the lowering of the water level due to the recirculation flow can be removed, and an interlocker predetermined in the defined water level can be actuated, thus the influence of the dynamic pressure due to the recirculation flow acting on the instrumental pipe line detecting the reactor water level can be removed effectively. (Yoshino, Y.)

  6. High-pressure plastic scintillation detector for measuring radiogenic gases in flow systems

    Science.gov (United States)

    Schell, W. R.; Vives-Batlle, J.; Yoon, S. R.; Tobin, M. J.

    1999-02-01

    Radioactive gases are emitted into the atmosphere from nuclear electric power and nuclear fuel reprocessing plants, from hospitals discarding xenon used in diagnostic medicine, as well as from nuclear weapons tests. A high-pressure plastic scintillation detector was constructed to measure atmospheric levels of such radioactive gases by detecting the beta and internal conversion (IC) electron decays. Operational tests and calibrations were made that permit integration of the flow detectors into a portable Gas Analysis, Separation and Purification system (GASP). The equipment developed can be used for measuring fission gases released from nuclear reactor sources and/or as part of monitoring equipment for enforcing the Comprehensive Test Ban Treaty. The detector is being used routinely for in-line gas separation efficiency measurements, at the elevated operational pressures used for the high-pressure swing analysis system (2070 kPa) and at flow rates of 5-15 l/min [1, 2]. This paper presents the design features, operational methods, calibration, and detector applications.

  7. High-pressure plastic scintillation detector for measuring radiogenic gases in flow systems

    International Nuclear Information System (INIS)

    Schell, W.R.; Vives-Batlle, J.; Yoon, S.R; Tobin, M.J.

    1999-01-01

    Radioactive gases are emitted into the atmosphere from nuclear electric power and nuclear fuel reprocessing plants, from hospitals discarding xenon used in diagnostic medicine, as well as from nuclear weapons tests. A high-pressure plastic scintillation detector was constructed to measure atmospheric levels of such radioactive gases by detecting the beta and internal conversion (IC) electron decays. Operational tests and calibrations were made that permit integration of the flow detectors into a portable Gas Analysis, Separation and Purification system (GASP). The equipment developed can be used for measuring fission gases released from nuclear reactor sources and/or as part of monitoring equipment for enforcing the Comprehensive Test Ban Treaty. The detector is being used routinely for in-line gas separation efficiency measurements, at the elevated operational pressures used for the high-pressure swing analysis system (2070 kPa) and at flow rates of 5-15 l/min . This paper presents the design features, operational methods, calibration, and detector applications

  8. Measurement of the resistivity of porous materials with an alternating air-flow method.

    Science.gov (United States)

    Dragonetti, Raffaele; Ianniello, Carmine; Romano, Rosario A

    2011-02-01

    Air-flow resistivity is a main parameter governing the acoustic behavior of porous materials for sound absorption. The international standard ISO 9053 specifies two different methods to measure the air-flow resistivity, namely a steady-state air-flow method and an alternating air-flow method. The latter is realized by the measurement of the sound pressure at 2 Hz in a small rigid volume closed partially by the test sample. This cavity is excited with a known volume-velocity sound source implemented often with a motor-driven piston oscillating with prescribed area and displacement magnitude. Measurements at 2 Hz require special instrumentation and care. The authors suggest an alternating air-flow method based on the ratio of sound pressures measured at frequencies higher than 2 Hz inside two cavities coupled through a conventional loudspeaker. The basic method showed that the imaginary part of the sound pressure ratio is useful for the evaluation of the air-flow resistance. Criteria are discussed about the choice of a frequency range suitable to perform simplified calculations with respect to the basic method. These criteria depend on the sample thickness, its nonacoustic parameters, and the measurement apparatus as well. The proposed measurement method was tested successfully with various types of acoustic materials.

  9. A Manganin Thin Film Ultra-High Pressure Sensor for Microscale Detonation Pressure Measurement

    Directory of Open Access Journals (Sweden)

    Guodong Zhang

    2018-03-01

    Full Text Available With the development of energetic materials (EMs and microelectromechanical systems (MEMS initiating explosive devices, the measurement of detonation pressure generated by EMs in the microscale has become a pressing need. This paper develops a manganin thin film ultra-high pressure sensor based on MEMS technology for measuring the output pressure from micro-detonator. A reliable coefficient is proposed for designing the sensor’s sensitive element better. The sensor employs sandwich structure: the substrate uses a 0.5 mm thick alumina ceramic, the manganin sensitive element with a size of 0.2 mm × 0.1 mm × 2 μm and copper electrodes of 2 μm thick are sputtered sequentially on the substrate, and a 25 μm thick insulating layer of polyimide is wrapped on the sensitive element. The static test shows that the piezoresistive coefficient of manganin thin film is 0.0125 GPa−1. The dynamic experiment indicates that the detonation pressure of micro-detonator is 12.66 GPa, and the response time of the sensor is 37 ns. In a word, the sensor developed in this study is suitable for measuring ultra-high pressure in microscale and has a shorter response time than that of foil-like manganin gauges. Simultaneously, this study could be beneficial to research on ultra-high-pressure sensors with smaller size.

  10. Design of a Continuous Blood Pressure Measurement System Based on Pulse Wave and ECG Signals.

    Science.gov (United States)

    Li, Jian-Qiang; Li, Rui; Chen, Zhuang-Zhuang; Deng, Gen-Qiang; Wang, Huihui; Mavromoustakis, Constandinos X; Song, Houbing; Ming, Zhong

    2018-01-01

    With increasingly fierce competition for jobs, the pressures on people have risen in recent years, leading to lifestyle and diet disorders that result in significantly higher risks of cardiovascular disease. Hypertension is one of the common chronic cardiovascular diseases; however, mainstream blood pressure measurement devices are relatively heavy. When multiple measurements are required, the user experience and the measurement results may be unsatisfactory. In this paper, we describe the design of a signal collection module that collects pulse waves and electrocardiograph (ECG) signals. The collected signals are input into a signal processing module to filter the noise and amplify the useful physiological signals. Then, we use a wavelet transform to eliminate baseline drift noise and detect the feature points of the pulse waves and ECG signals. We propose the concept of detecting the wave shape associated with an instance, an approach that minimizes the impact of atypical pulse waves on blood pressure measurements. Finally, we propose an improved method for measuring blood pressure based on pulse wave velocity that improves the accuracy of blood pressure measurements by 58%. Moreover, the results meet the american medical instrument promotion association standards, which demonstrate the feasibility of our measurement system.

  11. Measurement of gas adsorption with Jäntti's method using continuously increasing pressure

    NARCIS (Netherlands)

    Poulis, J.A.; Massen, C.H.; Robens, E.

    2002-01-01

    Jäntti et al. published a method to reduce the time necessary for adsorption measurements. They proposed to extrapolate the equilibrium in the stepwise isobaric measurement of adsorption isotherms by measuring at each step three points of the kinetic curve. For that purpose they approximated the

  12. Effect of instantaneous rotational speed on the analysis of measured diesel engine cylinder pressure data

    International Nuclear Information System (INIS)

    Antonopoulos, Antonis K.; Hountalas, Dimitrios T.

    2012-01-01

    Highlights: ► The effect of in-cycle speed fluctuation on cylinder pressure measurement is investigated. ► A phasing error is introduced when sampling cylinder pressure at constant time intervals. ► The phasing error increases with the increase of engine load and decrease of engine speed. ► Measurement using constant sampling rate affects estimation of HRR, ignition angle etc. - Abstract: Diesel engine cylinder pressure measurements are widely used in field and lab applications to support among other control, monitoring and diagnostic applications. There are two methods to measure cylinder pressure, the use of a crank angle encoder, which guarantees pressure samples at fixed crank angles, and the use of constant time sampling rate. The last is frequently used due to its simplicity or because of practical restrictions. However, in order to perform thermodynamic calculations it is necessary to attribute a crank angle value to each measured pressure value. But if the in-cycle rotational speed fluctuates and this is neglected, an error will result in the values derived from the processing of the measured cylinder pressure. For this reason in the present work an experimental investigation is conducted on a single cylinder diesel test engine to identify the aforementioned problem. During the tests cylinder pressure and instantaneous speed were recorded using an accurate crank angle reference. These where then used to simulate the measurement of cylinder pressure digitized using a fixed time step. The comparison of the two cylinder pressure traces and the thermodynamic parameters derived from them, reveals the introduction of an error which depends on engine load and speed.

  13. Pressurized transient otoacoustic emissions measured using click and chirp stimuli.

    Science.gov (United States)

    Keefe, Douglas H; Patrick Feeney, M; Hunter, Lisa L; Fitzpatrick, Denis F; Sanford, Chris A

    2018-01-01

    Transient-evoked otoacoustic emission (TEOAE) responses were measured in normal-hearing adult ears over frequencies from 0.7 to 8 kHz, and analyzed with reflectance/admittance data to measure absorbed sound power and the tympanometric peak pressure (TPP). The mean TPP was close to ambient. TEOAEs were measured in the ear canal at ambient pressure, TPP, and fixed air pressures from 150 to -200 daPa. Both click and chirp stimuli were used to elicit TEOAEs, in which the incident sound pressure level was constant across frequency. TEOAE levels were similar at ambient and TPP, and for frequencies from 0.7 to 2.8 kHz decreased with increasing positive and negative pressures. At 4-8 kHz, TEOAE levels were larger at positive pressures. This asymmetry is possibly related to changes in mechanical transmission through the ossicular chain. The mean TEOAE group delay did not change with pressure, although small changes were observed in the mean instantaneous frequency and group spread. Chirp TEOAEs measured in an adult ear with Eustachian tube dysfunction and TPP of -165 daPa were more robust at TPP than at ambient. Overall, results demonstrate the feasibility and clinical potential of measuring TEOAEs at fixed pressures in the ear canal, which provide additional information relative to TEOAEs measured at ambient pressure.

  14. A statistical method for draft tube pressure pulsation analysis

    International Nuclear Information System (INIS)

    Doerfler, P K; Ruchonnet, N

    2012-01-01

    Draft tube pressure pulsation (DTPP) in Francis turbines is composed of various components originating from different physical phenomena. These components may be separated because they differ by their spatial relationships and by their propagation mechanism. The first step for such an analysis was to distinguish between so-called synchronous and asynchronous pulsations; only approximately periodic phenomena could be described in this manner. However, less regular pulsations are always present, and these become important when turbines have to operate in the far off-design range, in particular at very low load. The statistical method described here permits to separate the stochastic (random) component from the two traditional 'regular' components. It works in connection with the standard technique of model testing with several pressure signals measured in draft tube cone. The difference between the individual signals and the averaged pressure signal, together with the coherence between the individual pressure signals is used for analysis. An example reveals that a generalized, non-periodic version of the asynchronous pulsation is important at low load.

  15. A noncontact intraocular pressure measurement device using a micro reflected air pressure sensor for the prediagnosis of glaucoma

    International Nuclear Information System (INIS)

    Kim, Kyoung Hwan; Kim, Byeong Hee; Seo, Young Ho

    2012-01-01

    This study investigates a novel, portable tonometer using a micro reflected air pressure sensor for the prediagnosis of glaucoma. Because glaucoma progresses slowly and is not painful, glaucoma patients require a portable prediagnosis system to periodically measure intraocular pressure at home. Conventionally, intraocular pressure is measured by an air-puff tonometer whereby the cornea is deformed by a short pulse of air pressure and the magnitude of the corneal deformation is measured by optic systems such as a combination of laser- and photodiodes. In this study, a micro reflected air pressure sensor was designed, fabricated, and tested in order to measure the magnitude of corneal deformation without optic systems. In an experimental study, artificial eyes with different internal pressures were fabricated and these pressures were measured by the aforementioned system. (paper)

  16. Comparison of Doppler and oscillometric ankle blood pressure measurement in patients with angiographically documented lower extremity arterial occlusive disease.

    Science.gov (United States)

    Nukumizu, Yoshihito; Matsushita, Masahiro; Sakurai, Tsunehisa; Kobayashi, Masayoshi; Nishikimi, Naomichi; Komori, Kimihiro

    2007-01-01

    To assess the reliability of the oscillometric method in patients with peripheral vascular disease, ankle blood pressure measurement by Doppler and oscillometry was compared. This study represents a prospective, non-blinded examination of pressure measurements in 168 patients. Twenty-two patients were included who had abdominal aortic aneurysms (AAA) and 146 had peripheral arterial occlusive disease (PAOD). Patients with PAOD were divided into 2 groups according to angiography results: a crural artery occlusion group (CAO, n = 32), and a no crural artery occlusion group (NCAO, n = 114). All subjects underwent pressure measurement by both Doppler and oscillometry. The correlation coefficient was 0.928 in AAA patients and 0.922 in PAOD patients. In CAO patients, there were significantly fewer patients whose oscillometric pressure was equivalent to the Doppler pressure (DP), as compared to NCAO patients, because the oscillometric pressure (OP) was 10% higher than DP in 44% of CAO patients. A high correlation exists between Doppler and oscillometric ankle pressure measurements irrespective of the type of vascular disease. However, the oscillometric method could not be substituted for the Doppler method completely, because there were several patients whose OP was greater than DP especially in those with crural artery occlusive disease.

  17. Automatic Blood Pressure Measurements During Exercise

    Science.gov (United States)

    Weaver, Charles S.

    1985-01-01

    Microprocessor circuits and a computer algorithm for automatically measuring blood pressure during ambulatory monitoring and exercise stress testing have been under development at SRI International. A system that records ECG, Korotkov sound, and arm cuff pressure for off-line calculation of blood pressure has been delivered to NASA, and an LSLE physiological monitoring system that performs the algorithm calculations in real-time is being constructed. The algorithm measures the time between the R-wave peaks and the corresponding Korotkov sound on-set (RK-interval). Since the curve of RK-interval versus cuff pressure during deflation is predictable and slowly varying, windows can be set around the curve to eliminate false Korotkov sound detections that result from noise. The slope of this curve, which will generally decrease during exercise, is the inverse of the systolic slope of the brachial artery pulse. In measurements taken during treadmill stress testing, the changes in slopes of subjects with coronary artery disease were markedly different from the changes in slopes of healthy subjects. Measurements of slope and O2 consumption were also made before and after ten days of bed rest during NASA/Ames Research Center bed rest studies. Typically, the maximum rate of O2 consumption during the post-bed rest test is less than the maximum rate during the pre-bed rest test. The post-bed rest slope changes differ from the pre-bed rest slope changes, and the differences are highly correlated with the drop in the maximum rate of O2 consumption. We speculate that the differences between pre- and post-bed rest slopes are due to a drop in heart contractility.

  18. Pressure-surge mitigation methods in fluid-conveying piping

    International Nuclear Information System (INIS)

    Shin, Y.W.; Youngdahl, C.K.; Wiedermann, A.H.

    1991-01-01

    Pressure surges in the heat transport system of nuclear reactor plants can affect the safety and reliability of the plants. Hence the pressure surges must be considered in the design, operation, and maintenance of the plants in order to minimize their occurrence and impacts. The objectives of this paper are to review various methods to control or mitigate the pressure surges, to analyze these methods to gain understanding of the mitigation mechanisms, and examine applicability of the methods to nuclear power plants. 6 refs., 13 figs

  19. Method and apparatus for reconstructing in-cylinder pressure and correcting for signal decay

    Science.gov (United States)

    Huang, Jian

    2013-03-12

    A method comprises steps for reconstructing in-cylinder pressure data from a vibration signal collected from a vibration sensor mounted on an engine component where it can generate a signal with a high signal-to-noise ratio, and correcting the vibration signal for errors introduced by vibration signal charge decay and sensor sensitivity. The correction factors are determined as a function of estimated motoring pressure and the measured vibration signal itself with each of these being associated with the same engine cycle. Accordingly, the method corrects for charge decay and changes in sensor sensitivity responsive to different engine conditions to allow greater accuracy in the reconstructed in-cylinder pressure data. An apparatus is also disclosed for practicing the disclosed method, comprising a vibration sensor, a data acquisition unit for receiving the vibration signal, a computer processing unit for processing the acquired signal and a controller for controlling the engine operation based on the reconstructed in-cylinder pressure.

  20. Standard Test Method for Calculation of Stagnation Enthalpy from Heat Transfer Theory and Experimental Measurements of Stagnation-Point Heat Transfer and Pressure

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the calculation from heat transfer theory of the stagnation enthalpy from experimental measurements of the stagnation-point heat transfer and stagnation pressure. 1.2 Advantages 1.2.1 A value of stagnation enthalpy can be obtained at the location in the stream where the model is tested. This value gives a consistent set of data, along with heat transfer and stagnation pressure, for ablation computations. 1.2.2 This computation of stagnation enthalpy does not require the measurement of any arc heater parameters. 1.3 Limitations and ConsiderationsThere are many factors that may contribute to an error using this type of approach to calculate stagnation enthalpy, including: 1.3.1 TurbulenceThe turbulence generated by adding energy to the stream may cause deviation from the laminar equilibrium heat transfer theory. 1.3.2 Equilibrium, Nonequilibrium, or Frozen State of GasThe reaction rates and expansions may be such that the gas is far from thermodynamic equilibrium. 1.3.3 Noncat...

  1. Application of SH surface acoustic waves for measuring the viscosity of liquids in function of pressure and temperature.

    Science.gov (United States)

    Kiełczyński, P; Szalewski, M; Balcerzak, A; Rostocki, A J; Tefelski, D B

    2011-12-01

    Viscosity measurements were carried out on triolein at pressures from atmospheric up to 650 MPa and in the temperature range from 10°C to 40°C using ultrasonic measuring setup. Bleustein-Gulyaev SH surface acoustic waves waveguides were used as viscosity sensors. Additionally, pressure changes occurring during phase transition have been measured over the same temperature range. Application of ultrasonic SH surface acoustic waves in the liquid viscosity measurements at high pressure has many advantages. It enables viscosity measurement during phase transitions and in the high-pressure range where the classical viscosity measurement methods cannot operate. Measurements of phase transition kinetics and viscosity of liquids at high pressures and various temperatures (isotherms) is a novelty. The knowledge of changes in viscosity in function of pressure and temperature can help to obtain a deeper insight into thermodynamic properties of liquids. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Theory and Practice - Measuring High-Pressure Electronic and Magnetic Properties

    International Nuclear Information System (INIS)

    Hemley, R.J.; Struzhkin, V.V.; Cohen, R.E.

    2008-01-01

    Measurements of the electronic and magnetic properties of Earth and planetary materials at high pressure play a crucial role in modern geoscience. There have been numerous advances in the field, primarily as a result of developments in diamond-anvil cell methods. In particular, synchrotron radiation techniques play an especially important role. The chapter begins with a short review of fundamental properties of the relevant materials, with emphasis on how these are altered under very high pressures and temperatures of the Earth's deep interior, followed by a discussion of different classes of electronic and magnetic excitations. Various techniques currently used for high-pressure studies are then described, beginning with optical spectroscopies, Moessbauer spectroscopy, elastic X-ray and neutron scattering, many new X-ray spectroscopy and inelastic scattering methods, transport techniques, and finally resonance methods. Selected examples of the techniques are given, with a common theme being the high P-T behavior of iron-containing oxides, silicates, and metals at conditions found throughout the Earth's interior. Applications to upper-mantle phases, 'simple' oxides, silicate perovskite and post-perovskite, volatiles, and iron and iron alloys are discussed, with an emphasis given to integrated studies utilizing a combination of different techniques to understand high P-T electronic and magnetic phenomena.

  3. A Computer Controlled Precision High Pressure Measuring System

    Science.gov (United States)

    Sadana, S.; Yadav, S.; Jha, N.; Gupta, V. K.; Agarwal, R.; Bandyopadhyay, A. K.; Saxena, T. K.

    2011-01-01

    A microcontroller (AT89C51) based electronics has been designed and developed for high precision calibrator based on Digiquartz pressure transducer (DQPT) for the measurement of high hydrostatic pressure up to 275 MPa. The input signal from DQPT is converted into a square wave form and multiplied through frequency multiplier circuit over 10 times to input frequency. This input frequency is multiplied by a factor of ten using phased lock loop. Octal buffer is used to store the calculated frequency, which in turn is fed to microcontroller AT89C51 interfaced with a liquid crystal display for the display of frequency as well as corresponding pressure in user friendly units. The electronics developed is interfaced with a computer using RS232 for automatic data acquisition, computation and storage. The data is acquired by programming in Visual Basic 6.0. This system is interfaced with the PC to make it a computer controlled system. The system is capable of measuring the frequency up to 4 MHz with a resolution of 0.01 Hz and the pressure up to 275 MPa with a resolution of 0.001 MPa within measurement uncertainty of 0.025%. The details on the hardware of the pressure measuring system, associated electronics, software and calibration are discussed in this paper.

  4. Employment of a novel ultrasonic method to investigate high pressure phase transitions in oleic acid

    Science.gov (United States)

    Rostocki, A. J.; Siegoczyński, R. M.; Kiełczyński, P.; Szalewski, M.; Balcerzak, A.; Zduniak, M.

    2011-06-01

    In this work, the variation of sound velocity with hydrostatic pressure for oleic acid is evaluated up to 350 MPa. During the measurement, we identified the phase transformation of oleic acid and the presence of the hysteresis of the dependence of sound velocity on pressure. From the performed measurements, it can be seen that the dependence of sound velocity on pressure can be used to investigate phase transformations in natural oils. Ultrasonic waves were excited and detected using piezoelectric LiNbO3(Y-36 cut) 5 MHz transducers. The phase velocity of the longitudinal ultrasonic waves was measured using a cross-correlation method to evaluate the time of flight.

  5. Pressure-volume-temperature gauging method experiment using liquid nitrogen under microgravity condition of parabolic flight

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Man Su; Park, Hana; Yoo, Don Gyu; Jeong, Sang Kwon [Cryogenic Engineering Laboratory, Department of Mechanical Engineering, KAIST, Daejeon (Korea, Republic of); Jung, Young Suk [Launcher Systems Development Team, Korea Aerospace Research Institute, Daejeon (Korea, Republic of)

    2014-06-15

    Measuring an exact amount of remaining cryogenic liquid propellant under microgravity condition is one of the important issues of rocket vehicle. A Pressure-Volume-Temperature (PVT) gauging method is attractive due to its minimal additional hardware and simple gauging process. In this paper, PVT gauging method using liquid nitrogen is investigated under microgravity condition with parabolic flight. A 9.2 litre metal cryogenic liquid storage tank containing approximately 30% of liquid nitrogen is pressurized by ambient temperature helium gas. During microgravity condition, the inside of the liquid tank becomes near-isothermal condition within 1 K difference indicated by 6 silicon diode sensors vertically distributed in the middle of the liquid tank. Helium injection with higher mass flow rate after 10 seconds of the waiting time results in successful measurements of helium partial pressure in the tank. Average liquid volume measurement error is within 11% of the whole liquid tank volume and standard deviation of errors is 11.9. As a result, the applicability of PVT gauging method to liquid.

  6. Pressure-volume-temperature gauging method experiment using liquid nitrogen under microgravity condition of parabolic flight

    International Nuclear Information System (INIS)

    Seo, Man Su; Park, Hana; Yoo, Don Gyu; Jeong, Sang Kwon; Jung, Young Suk

    2014-01-01

    Measuring an exact amount of remaining cryogenic liquid propellant under microgravity condition is one of the important issues of rocket vehicle. A Pressure-Volume-Temperature (PVT) gauging method is attractive due to its minimal additional hardware and simple gauging process. In this paper, PVT gauging method using liquid nitrogen is investigated under microgravity condition with parabolic flight. A 9.2 litre metal cryogenic liquid storage tank containing approximately 30% of liquid nitrogen is pressurized by ambient temperature helium gas. During microgravity condition, the inside of the liquid tank becomes near-isothermal condition within 1 K difference indicated by 6 silicon diode sensors vertically distributed in the middle of the liquid tank. Helium injection with higher mass flow rate after 10 seconds of the waiting time results in successful measurements of helium partial pressure in the tank. Average liquid volume measurement error is within 11% of the whole liquid tank volume and standard deviation of errors is 11.9. As a result, the applicability of PVT gauging method to liquid

  7. Reliability of in-Shoe Plantar Pressure Measurements in Rheumatoid Arthritis Patients

    Science.gov (United States)

    Vidmar, Gaj; Novak, Primoz

    2009-01-01

    Plantar pressures measurement is a frequently used method in rehabilitation and related research. Metric characteristics of the F-Scan system have been assessed from different standpoints and in different patients, but not its reliability in rheumatoid arthritis patients. Therefore, our objective was to assess reliability of the F-Scan plantar…

  8. Temperature measurement in the liquid helium range at pressure

    International Nuclear Information System (INIS)

    Itskevich, E.S.; Krajdenov, V.F.

    1978-01-01

    The use of bronze and germanium resistance thermometers and the use of a (Au + 0.07 % Fe)-Cu thermocouple for temperature measurements from 1.5 to 4.2 K in the hydrostatic compression of up to 10 kbar are considered. To this aim, the thermometer resistance as a function of temperature and pressure is measured. It is revealed that pressure does not change the thermometric response of the bronze resistance thermometer but only shifts it to the region of lower temperatures. The identical investigations of the germanium resistance thermometer shows that strong temperature dependence and the shift of its thermometric response under the influence of pressure make the use of germanium resistance thermometers in high-pressure chambers very inconvenient. The results of the analysis of the (Au + 0.07 % Fe) - Cu thermocouple shows that with a 2 per cent accuracy the thermocouple Seebeck coefficient does not depend on pressure. It permits to use this thermocouple for temperature measurements at high pressures

  9. Time-averaged second-order pressure and velocity measurements in a pressurized oscillating flow prime mover

    Energy Technology Data Exchange (ETDEWEB)

    Paridaens, Richard [DynFluid, Arts et Metiers, 151 boulevard de l' Hopital, Paris (France); Kouidri, Smaine [LIMSI-CNRS, Orsay Cedex (France)

    2016-11-15

    Nonlinear phenomena in oscillating flow devices cause the appearance of a relatively minor secondary flow known as acoustic streaming, which is superimposed on the primary oscillating flow. Knowledge of control parameters, such as the time-averaged second-order velocity and pressure, would elucidate the non-linear phenomena responsible for this part of the decrease in the system's energetic efficiency. This paper focuses on the characterization of a travelling wave oscillating flow engine by measuring the time-averaged second order pressure and velocity. Laser Doppler velocimetry technique was used to measure the time-averaged second-order velocity. As streaming is a second-order phenomenon, its measurement requires specific settings especially in a pressurized device. Difficulties in obtaining the proper settings are highlighted in this study. The experiments were performed for mean pressures varying from 10 bars to 22 bars. Non-linear effect does not constantly increase with pressure.

  10. Stroke Volume estimation using aortic pressure measurements and aortic cross sectional area: Proof of concept.

    Science.gov (United States)

    Kamoi, S; Pretty, C G; Chiew, Y S; Pironet, A; Davidson, S; Desaive, T; Shaw, G M; Chase, J G

    2015-08-01

    Accurate Stroke Volume (SV) monitoring is essential for patient with cardiovascular dysfunction patients. However, direct SV measurements are not clinically feasible due to the highly invasive nature of measurement devices. Current devices for indirect monitoring of SV are shown to be inaccurate during sudden hemodynamic changes. This paper presents a novel SV estimation using readily available aortic pressure measurements and aortic cross sectional area, using data from a porcine experiment where medical interventions such as fluid replacement, dobutamine infusions, and recruitment maneuvers induced SV changes in a pig with circulatory shock. Measurement of left ventricular volume, proximal aortic pressure, and descending aortic pressure waveforms were made simultaneously during the experiment. From measured data, proximal aortic pressure was separated into reservoir and excess pressures. Beat-to-beat aortic characteristic impedance values were calculated using both aortic pressure measurements and an estimate of the aortic cross sectional area. SV was estimated using the calculated aortic characteristic impedance and excess component of the proximal aorta. The median difference between directly measured SV and estimated SV was -1.4ml with 95% limit of agreement +/- 6.6ml. This method demonstrates that SV can be accurately captured beat-to-beat during sudden changes in hemodynamic state. This novel SV estimation could enable improved cardiac and circulatory treatment in the critical care environment by titrating treatment to the effect on SV.

  11. An instrument to measure differential pore pressures in deep ocean sediments: Pop-Up-Pore-Pressure-Instrument (PUPPI)

    International Nuclear Information System (INIS)

    Schultheiss, P.J.; McPhail, S.D.; Packwood, A.R.; Hart, B.

    1985-01-01

    A Pop-Up-Pore-Pressure-Instrument (PUPPI) has been developed to measure differential pore pressures in sediments. The differential pressure is the pressure above or below normal hydrostatic pressure at the depth of the measurement. It is designed to operate in water depths up to 6000 metres for periods of weeks or months, if required, and measures differential pore pressures at depths of up to 3 metres into the sediments with a resolution of 0.05 kPa. It is a free-fall device with a lance which penetrates the sediments. This lance and the ballast weight is disposed when the PUPPI is acoustically released from the sea floor. When combined with permeability and porosity values of deep-sea sediments the pore pressure measurements made using the PUPPI suggest advection velocities as low as 8.8 mm/yr. The mechanical, electrical and acoustic systems are described together with data obtained from both shallow and deep water trials. (author)

  12. High-resolution thermal expansion measurements under helium-gas pressure

    Science.gov (United States)

    Manna, Rudra Sekhar; Wolf, Bernd; de Souza, Mariano; Lang, Michael

    2012-08-01

    We report on the realization of a capacitive dilatometer, designed for high-resolution measurements of length changes of a material for temperatures 1.4 K ⩽ T ⩽ 300 K and hydrostatic pressure P ⩽ 250 MPa. Helium (4He) is used as a pressure-transmitting medium, ensuring hydrostatic-pressure conditions. Special emphasis has been given to guarantee, to a good approximation, constant-pressure conditions during temperature sweeps. The performance of the dilatometer is demonstrated by measurements of the coefficient of thermal expansion at pressures P ≃ 0.1 MPa (ambient pressure) and 104 MPa on a single crystal of azurite, Cu3(CO3)2(OH)2, a quasi-one-dimensional spin S = 1/2 Heisenberg antiferromagnet. The results indicate a strong effect of pressure on the magnetic interactions in this system.

  13. EVALUATION OF THE BLOOD PRESSURE MEASURING KNOWLEDGE OF THE NURSES WHO ARE WORKING IN A MEDICAL FACULTY HOSPITAL

    Directory of Open Access Journals (Sweden)

    Tahir Kemal SAHIN

    2006-02-01

    Full Text Available Objective: The aim of this study is to determine the right knowledge of blood pressure measurement of the nurses who working in clinics. Materials and Method: 103 nurses who are working in Meram Medical Faculty Hospital were included to this descriptive study. Sampling method was stratified proportional random sampling method, with strata for the number of nurses at clinics. A questionnaire, which was formed of some questions about standard measuring methods of blood pressure, was applied to the nurses. Results: It was determined that 55.3% to 98.1% of the nurses answered the most of the questions correctly. But, they gave different answers to the questions about choosing the arm for measurement, inflation level of the cuff, deflation speed and how many measurements should be done for true result. It was found that the female nurses had much more knowledge about the tension of wrapping the cuff around the arm and the correct positioning of the stethescope than the male ones. Oppositely, the male nurses had higher correct answer rate about deflation of the cuff than the female nurses. Conclusion: It was concluded that the knowledge of blood pressure measurement of the nurses was partly insufficient. Periodical educational studies should be done for the nurses to complete the blood pressure measurement knowledge of them. [TAF Prev Med Bull 2006; 5(1.000: 8-18

  14. Monitoring the aging of pressure vessel steels by TEP measurements: Advantages and current limitations of the method

    International Nuclear Information System (INIS)

    Kleber, X.; Saillet, S.

    2011-01-01

    The TEP (Thermoelectric Power or Seebeck coefficient) characterizes the ability of a material to generate an electrical potential difference when the material is subjected to a heat flux. It can be defined from the Seebeck effect, which manifests itself in a circuit formed by two different metals subjected to a temperature gradient. The origin of the thermoelectric power is, as the resistivity, due to electronic phenomena occurring at the atomic scale in relation to the crystallographic structure of the material. TEP measurements are used to characterize small microstructural changes at the scale of crystal defects. The high sensitivity of TEP makes it an excellent probe able of detecting small changes in the microstructural state, including precipitation, dissolution of alloying elements, hardening and recovery after deformation. It has been shown recently that the TEP of pressure vessels steels was sensitive to irradiation, making this measurement technique a potential candidate for monitoring the aging of the pressure vessel steel. However, the first measurements on Charpy specimens of the EDF monitoring program (Pressure Vessel Surveillance Program) showed a strong negative effect of specimen geometry on the accuracy that can be achieved. In this paper we show what the origins of these inaccuracies are. From numerical simulation and finite element model, we describe the roles of the thermal contact resistance as well as the influence of the geometry of the blocks device. A model is proposed to overcome these negative effects. We also show the effect of the presence of heterogeneities in the material on the TEP measurement, and the importance of their localization. Finally, solutions are proposed to improve the device for measuring TEP on PVSP Charpy specimens. (authors)

  15. Extension of the thermal porosimetry method to high gas pressure for nanoporosimetry estimation

    Science.gov (United States)

    Jannot, Y.; Degiovanni, A.; Camus, M.

    2018-04-01

    Standard pore size determination methods like mercury porosimetry, nitrogen sorption, microscopy, or X-ray tomography are not suited to highly porous, low density, and thus very fragile materials. For this kind of materials, a method based on thermal characterization has been developed in a previous study. This method has been used with air pressure varying from 10-1 to 105 Pa for materials having a thermal conductivity less than 0.05 W m-1 K-1 at atmospheric pressure. It enables the estimation of pore size distribution between 100 nm and 1 mm. In this paper, we present a new experimental device enabling thermal conductivity measurement under gas pressure up to 106 Pa, enabling the estimation of the volume fraction of pores having a 10 nm diameter. It is also demonstrated that the main thermal conductivity models (parallel, series, Maxwell, Bruggeman, self-consistent) lead to the same estimation of the pore size distribution as the extended parallel model (EPM) presented in this paper and then used to process the experimental data. Three materials with thermal conductivities at atmospheric pressure ranging from 0.014 W m-1 K-1 to 0.04 W m-1 K-1 are studied. The thermal conductivity measurement results obtained with the three materials are presented, and the corresponding pore size distributions between 10 nm and 1 mm are presented and discussed.

  16. Definition-consistent measurement of exchange market pressure

    NARCIS (Netherlands)

    Klaassen, F.; Jager, H.

    2011-01-01

    Currencies can be under severe pressure, but in a managed exchange rate regime that is not fully visible via the change in the exchange rate. The literature has proposed a way to measure such exchange market pressure (EMP) indirectly, by adding interest rate changes and forex interventions to the

  17. Intra-Ocular Pressure Measurement in a Patient with a Thin, Thick or Abnormal Cornea.

    Science.gov (United States)

    Clement, Colin I; Parker, Douglas G A; Goldberg, Ivan

    2016-01-01

    Accurate measurement of intra-ocular pressure is a fundamental component of the ocular examination. The most common method of measuring IOP is by Goldmann applanation tonometry, the accuracy of which is influenced by the thickness and biomechanical properties of the cornea. Algorithms devised to correct for corneal thickness to estimate IOP oversimplify the effects of corneal biomechanics. The viscous and elastic properties of the cornea influence IOP measurements in unpredictable ways, a finding borne out in studies of patients with inherently abnormal and surgically altered corneal biomechanics. Dynamic contour tonometry, rebound tonometry and the ocular response analyzer provide useful alternatives to GAT in patients with abnormal corneas, such as those who have undergone laser vision correction or keratoplasty. This article reviews the various methods of intra-ocular pressure measurement available to the clinician and the ways in which their utility is influenced by variations in corneal thickness and biomechanics.

  18. A study of dynamic foot pressure measurement in diabetic patients

    Directory of Open Access Journals (Sweden)

    Milka D Madhale

    2017-01-01

    Full Text Available Introduction: Diabetic foot ulcer is a major source of morbidity and a leading cause of hospitalization. It is estimated that approximately 20% of hospital admissions among patients with diabetes mellitus are due to diabetic foot ulcer. It can lead to infection, gangrene, amputation, and even death if appropriate care is not provided. Overall, the lower limb amputation in diabetic patients is 15 times higher than in non-diabetics. In the majority of cases, the cause for the foot ulcer is the altered architecture of the foot due to neuropathy resulting in abnormal pressure points on the soles. Purpose: The aim of this study is to develop low cost, lightweight foot pressure scanner and check its reliability and validity which can help to prevent foot ulceration. Design/Methodology/Approach: In the present study, a low cost, lightweight foot pressure scanner is developed, and dynamic plantar pressures in a group of 110 Indian patients with diabetes with or without neuropathy and foot ulcers are measured. Practical Implications: If these pressure points can be detected, ulcers can be prevented by providing offloading footwear. Originality/Value: Differences are found in dynamic foot pressures in different study groups, namely, diabetic patients, patients with diabetic peripheral neuropathy, patients with foot ulcers, and nondiabetics. The differences are significant (P < 0.01, which showed the validity of the tool. Reliability and consistency of the tool was checked by test–retest method. Paper Type: Original Research work. Conclusion: Based on the results of the present study, it is concluded that the scanner is successfully developed and it can measure foot pressures. It is a novel device to proactively monitor foot health in diabetics in an effort to prevent and reduce diabetic foot complications.

  19. Side abutment pressure distribution by field measurement

    Energy Technology Data Exchange (ETDEWEB)

    Lian-guo Wang; Yang Song; Xing-hua He; Jian Zhang [State Key Laboratory for Geomechanics and Deep Underground Engineering, Xuzhou (China)

    2008-12-15

    Given the 7123 working face in the Qidong Coal Mine of the Wanbei Mining Group, nine dynamic roof monitors were installed in the crossheading to measure the amount and velocity of roof convergence in different positions and at different times and three steel bored stress sensors were installed in the return airway to measure rock stress at depth. On the basis of this arrangement, the rule of change of the distribution of the side abutment pressure with the advance of the working face and movement of overlying strata was studied. The rule of change and the stability of rock stress at depth were measured. Secondly, the affected area and stability time of the side abutment pressure were also studied. The results show that: 1) During working, the face advanced distance was from 157 m to 99 m, the process was not effected by mining induced pressure. When the distance was 82 m, the position of peak stress was 5 m away from the coal wall. When the distance was 37 m, the position of peak stress away from the coal wall was about 15 m to 20 m and finally reached a steady state; 2) the time and the range of the peak of side rock pressure obtained from stress sensors were consistent with the results from the dynamic roof monitors; 3) the position of the peak pressure was 25 m away from the coal wall. 14 refs., 6 figs.

  20. Fundamental characteristics and simplified evaluation method of dynamic earth pressure

    International Nuclear Information System (INIS)

    Nukui, Y.; Inagaki, Y.; Ohmiya, Y.

    1989-01-01

    In Japan, a method is commonly used in the evaluation of dynamic earth pressure acting on the underground walls of a deeply embedded nuclear reactor building. However, since this method was developed on the basis of the limit state of soil supported by retaining walls, the behavior of dynamic earth pressure acting on the embedded part of a nuclear reactor building may differ from the estimated by this method. This paper examines the fundamental characteristics of dynamic earth pressure through dynamic soil-structure interaction analysis. A simplified method to evaluate dynamic earth pressure for the design of underground walls of a nuclear reactor building is described. The dynamic earth pressure is fluctuating earth pressure during earthquake

  1. Measuring head for determining the pressure of fission gases released inside bars of nuclear fuel

    International Nuclear Information System (INIS)

    Granata, S.

    1984-01-01

    A measuring head suitable for determining the pressure of fission gases released inside non-instrumented bars of nuclear fuel (which have reached high irradiation levels), and for connection to said bars by a method which allows no escape of said active gases and does not cause appreciable disturbance either to the fuel or to the released fission gases, is disclosed. The head consists of a tubular casing adapted to be welded at one end to the bar, and having a metal bellows at its other end. A pointed metal bar is used to penetrate the bar by a blow to a pin, whereupon pressure variations within the casing are measured by a pressure measuring device having an iron core, the movement of the core, due to such pressure variations, being recorded by a differential transformer. (author)

  2. A pitfall in the measurement of arterial blood pressure in the ischaemic limb during elevation

    DEFF Research Database (Denmark)

    Bülow, J; Jelnes, Rolf

    1987-01-01

    In order to evaluate if elevation of the ischaemic limb above heart level is an alternative to the conventionally applied method with external counterpressure for estimation of skin perfusion pressure, femoral and popliteal artery pressures were measured directly in eight patients with occlusion...... of the superficial femoral artery. The measurements were done in the horizontal position and during elevation of the calf above heart level. During elevation relative blood flow, measured by arterio-venous oxygen saturation differences, decreased compared with the horizontal position. In contrast the popliteal...... arterial pressure decreased only by 20% of the value expected from the degree of elevation of the calf above the level of the heart. Thus, it could be calculated that calf vascular resistance increased two- to three-fold on average during elevation. Four patients were reexamined with the venous pressure...

  3. Heat transfer and pressure measurements for the SSME fuel turbine

    Science.gov (United States)

    Dunn, Michael G.; Kim, Jungho

    1991-01-01

    A measurement program is underway using the Rocketdyne two-stage Space Shuttle Main Engine (SSME) fuel turbine. The measurements use a very large shock tunnel to produce a short-duration source of heated and pressurized gas which is subsequently passed through the turbine. Within this environment, the turbine is operated at the design values of flow function, stage pressure ratio, stage temperature ratio, and corrected speed. The first stage vane row and the first stage blade row are instrumented in both the spanwise and chordwise directions with pressure transducers and heat flux gages. The specific measurements to be taken include time averaged surface pressure and heat flux distributions on the vane and blade, flow passage static pressure, flow passage total pressure and total temperature distributions, and phase resolved surface pressure and heat flux on the blade.

  4. New simple method for fast and accurate measurement of volumes

    International Nuclear Information System (INIS)

    Frattolillo, Antonio

    2006-01-01

    A new simple method is presented, which allows us to measure in just a few minutes but with reasonable accuracy (less than 1%) the volume confined inside a generic enclosure, regardless of the complexity of its shape. The technique proposed also allows us to measure the volume of any portion of a complex manifold, including, for instance, pipes and pipe fittings, valves, gauge heads, and so on, without disassembling the manifold at all. To this purpose an airtight variable volume is used, whose volume adjustment can be precisely measured; it has an overall capacity larger than that of the unknown volume. Such a variable volume is initially filled with a suitable test gas (for instance, air) at a known pressure, as carefully measured by means of a high precision capacitive gauge. By opening a valve, the test gas is allowed to expand into the previously evacuated unknown volume. A feedback control loop reacts to the resulting finite pressure drop, thus contracting the variable volume until the pressure exactly retrieves its initial value. The overall reduction of the variable volume achieved at the end of this process gives a direct measurement of the unknown volume, and definitively gets rid of the problem of dead spaces. The method proposed actually does not require the test gas to be rigorously held at a constant temperature, thus resulting in a huge simplification as compared to complex arrangements commonly used in metrology (gas expansion method), which can grant extremely accurate measurement but requires rather expensive equipments and results in time consuming methods, being therefore impractical in most applications. A simple theoretical analysis of the thermodynamic cycle and the results of experimental tests are described, which demonstrate that, in spite of its simplicity, the method provides a measurement accuracy within 0.5%. The system requires just a few minutes to complete a single measurement, and is ready immediately at the end of the process. The

  5. Measurement Methods to Determine Air Leakage Between Adjacent Zones

    Energy Technology Data Exchange (ETDEWEB)

    Hult, Erin L. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Dickerhoff, Darryl J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Price, Phillip N. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-09-01

    Air leakage between adjacent zones of a building can lead to indoor air quality and energy efficiency concerns, however there is no existing standard for measuring inter-zonal leakage. In this study, synthesized data and field measurements are analyzed in order to explore the uncertainty associated with different methods for collecting and analyzing fan pressurization measurements to calculate interzone leakage.

  6. Vapor Pressure Measurements of LiBH4, NaBH 4 and Ca(BH4)2 using Knudsen Torsion Effusion Gravimetric Method

    Science.gov (United States)

    Danyan, Mohammad Masoumi

    Hydrogen storage is one of the critical technologies needed on the path towards commercialization for mobile applications. In the past few years, a range of new light weight hydrogen containing material has been discovered with good storage properties. Among them, lithium borohydride (LiBH 4) sodium borohydride (NaBH4) and calcium borohydride (Ca(BH 4)2) have shown promising results to be used as solid state hydrogen storage material. In this work, we have determined equilibrium vapor pressures of LiBH 4 NaBH4 and Ca(BH4)2 obtained by Torsion effusion thermogravimetric method. Results for all the three hydrides exhibited that a small fraction of the materials showed congruency, and sublimed as gaseous compound, but the majority of the material showed incongruent vaporization. Two Knudsen cells of 0.3 and 0.6mm orifice size was employed to measure the total vapor pressures. A Whitman-Motzfeldt method is used to extrapolate the measured vapor pressures to zero orifice size to calculate the equilibrium vapor pressures. In the case of LiBH4 we found that 2% of the material evaporated congruently (LiBH4(s) → LiBH4(g)) according to the equation: logPLiBH4/P 0 =-3263.5 +/-309/T + (1.079 +/-0.69) and rest as incongruent vaporization to LiH, B, and hydrogen gas according to the equation logPeq/P0 =(-3263.5 +/-309)/T+ (2.458 +/-0.69) with DeltaH evap.= 62.47+/-5.9 kJ/mol of H2, DeltaSevap. = 47.05+/-13 J/mol of H2.K. The NaBH4 also had somewhat similar behavior, with 9% congruent evaporation and equilibrium vapor pressure equation of logPLiBH4=-7700+/-335/ T+ (6.7+/-1.5) and 91% incongruent decomposition to Na and Boron metal, and hydrogen gas. The enthalpy of vaporization; DeltaHevap. = 147.2+/-6.4kJ/molH2 and DeltaSevap.= 142 +/-28 kJ/molH2.K (550-650K). The Ca(BH4) 2 exhibited similar vaporization behavior with congruency of 3.2%. The decomposition products are CaH2 and Boron metal with evolution of hydrogen gas varying with the pressure equation as logPeq /P0 =(-1562

  7. High-pressure plastic scintillation detector for measuring radiogenic gases in flow systems

    International Nuclear Information System (INIS)

    Schell, W.R.; Tobin, M.J.; Vives-Batlle, J.; Yoon, S.R.

    1999-01-01

    Radioactive gases are emitted into the atmosphere from nuclear electric power and nuclear fuel reprocessing plants, from hospitals discarding xenon used in diagnostic medicine, as well as from nuclear weapons tests. A high-pressure plastic scintillation detector was constructed to measure atmospheric levels of such radioactive gases by detecting the beta and internal conversion (IC) electron decays. Operational tests and calibrations were made that permit integration of the flow detectors into a portable Gas Analysis, Separation and Purification system (GASP). The equipment developed can be used for measuring fission gases released from nuclear reactor sources and/or as part of monitoring equipment for enforcing the Comprehensive Test Ban Treaty. The detector is being used routinely for in-line gas separation efficiency measurements, at the elevated operational pressures used for the high-pressure swing analysis system (2070 kPa) and at flow rates of 5-15 l/min. This paper presents the design features, operational methods, calibration, and detector applications. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  8. Real-time determination of fringe pattern frequencies: An application to pressure measurement

    Science.gov (United States)

    Sciammarella, Cesar A.; Piroozan, Parham

    2007-05-01

    Retrieving information in real time from fringe patterns is a topic of a great deal of interest in scientific and engineering applications of optical methods. This paper presents a method for fringe frequency determination based on the capability of neural networks to recognize signals that are similar but not identical to signals used to train the neural network. Sampled patterns are generated by calibration and stored in memory. Incoming patterns are analyzed by a back-propagation neural network at the speed of the recording device, a CCD camera. This method of information retrieval is utilized to measure pressures on a boundary layer flow. The sensor combines optics and electronics to analyze dynamic pressure distributions and to feed information to a control system that is capable to preserve the stability of the flow.

  9. The optimal scheme of self blood pressure measurement as determined from ambulatory blood pressure recordings

    NARCIS (Netherlands)

    Verberk, Willem J.; Kroon, Abraham A.; Kessels, Alfons G. H.; Lenders, Jacques W. M.; Thien, Theo; van Montfrans, Gert A.; Smit, Andries J.; de Leeuw, Peter W.

    Objective To determine how many self-measurements of blood pressure (BP) should be taken at home in order to obtain a reliable estimate of a patient's BP. Design Participants performed self blood pressure measurement (SBPM) for 7 days (triplicate morning and evening readings). In all of them, office

  10. Radiation Pressure Measurements on Micron-Size Individual Dust Grains

    Science.gov (United States)

    Abbas, M. M.; Craven, P. D.; Spann, J. F.; Witherow, W. K.; West, E. A.; Gallagher, D. L.; Adrian, M. L.; Fishman, G. J.; Tankosic, D.; LeClair, A.

    2003-01-01

    Measurements of electromagnetic radiation pressure have been made on individual silica (SiO2) particles levitated in an electrodynamic balance. These measurements were made by inserting single charged particles of known diameter in the 0.2- to 6.82-micron range and irradiating them from above with laser radiation focused to beam widths of approximately 175- 400 microns at ambient pressures particle due to the radiation force is balanced by the electrostatic force indicated by the compensating dc potential applied to the balance electrodes, providing a direct measure of the radiation force on the levitated particle. Theoretical calculations of the radiation pressure with a least-squares fit to the measured data yield the radiation pressure efficiencies of the particles, and comparisons with Mie scattering theory calculations provide the imaginary part of the refractive index of SiO2 and the corresponding extinction and scattering efficiencies.

  11. Temperature measurement in low pressure plasmas. Temperaturmessungen im Niederdruckplasma

    Energy Technology Data Exchange (ETDEWEB)

    Rosenbauer, K.A.; Wilting, H.; Schramm, G. (Duesseldorf Univ. (Germany, F.R.). Abt. fuer Histologie und Embryologie)

    1989-11-01

    The present work discusses the influence of various parameters on the substrate temperature in a low pressure plasma. The measurement method chosen utilized Signotherm (Merck) temperature sensors embedded in silicon between two glass substrates. All measurements were made in a 200 G Plasma Processor from Technics Plasma GmbH. The substrate temperature is dependent on the process time, the RF power, the process gas and the position in the chamber. The substrate temperature increases with increasing process time and increasing power. Due to the location of the microwave port from the magnetron to the chamber, the substrate temperature is highest in the center of the chamber. Measurements performed in an air plasma yielded higher results than in an oxygen plasma. (orig.).

  12. Method for acquiring pressure measurements in presence of plasma-induced interference for supersonic flow control applications

    International Nuclear Information System (INIS)

    Narayanaswamy, Venkateswaran; Clemens, Noel T; Raja, Laxminarayan L

    2011-01-01

    The operation of pulsed-plasma actuators for flow control is often associated with the presence of charged species in the flow and severe electromagnetic interference with external circuitry. These effects can lead to time-resolved transducer pressure measurements that are contaminated with electromagnetic interference effects or even transducer damage due to the interaction with charged species. A new technique is developed that enables high-bandwidth pressure measurements to be made in the presence of such rapidly switched plasma actuators. The technique is applied for the specific configuration of a pulsed-plasma jet actuator (spark jet) that is used to control the unsteadiness of a shock wave/boundary layer interaction generated by a compression ramp in a Mach 3 flow. The critical component of the technique involves using a pulsed-ground electrode to drain the charged species from the plasma jet before they reach the pressure transducer. The pulsed-ground electrode was shown to drain charged species into the pulsed ground prior to interacting with the transducer, which made it possible to make measurements without damaging the transducer. The resulting signals were still contaminated by electromagnetic interference spikes and so a data-processing technique was used to remove the artifacts and recover a largely uncontaminated power spectrum. The signal processing scheme used interpolation schemes previously developed for laser Doppler velocimetry applications. The data-processing procedure is demonstrated with a benchmark case in which the electromagnetic interference was isolated from the pulsed-plasma jet actuation effect. It is shown that the data-processing procedure removed the contamination from the electromagnetic interference at all frequencies but for the pulsing frequency and its higher harmonics

  13. Time response measurements of pressure sensors using pink noise technique

    International Nuclear Information System (INIS)

    Pereira, Iraci Martinez; Santos, Roberto Carlos dos

    2009-01-01

    This work presents an experimental setup for Pink Noise method application on pressure transmitters' response times. The Pink Noise method consists on injecting artificial pressure noise into the pressure transmitter. The artificial pressure noise is generated using a current-to-pressure (I-to-P) converter, which is driven by a random noise signal generator. The output pressure transmitter noise is then analyzed using conventional Noise Analysis Technique. Noise signals may be interpreted using spectral techniques or empirical time series models. The frequency domain method consists of evaluating the Power Spectral Density (PSD) function. The information needed for time constant estimation can be obtained by fitting an all-pole transfer function to this power spectral density. (author)

  14. Planar Pressure Field Determination in the Initial Merging Zone of an Annular Swirling Jet Based on Stereo-PIV Measurements

    Directory of Open Access Journals (Sweden)

    Eric Van den Bulck

    2008-11-01

    Full Text Available In this paper the static pressure field of an annular swirling jet is measured indirectly using stereo-PIV measurements. The pressure field is obtained from numerically solving the Poisson equation, taken into account the axisymmetry of the flow. At the boundaries no assumptions are made and the exact boundary conditions are applied. Since all source terms can be measured using stereo-PIV and the boundary conditions are exact, no assumptions other than axisymmetry had to be made in the calculation of the pressure field. The advantage of this method of indirect pressure measurement is its high spatial resolution compared to the traditional pitot probes. Moreover this method is non-intrusive while the insertion of a pitot tube disturbs the flow. It is shown that the annular swirling flow can be divided into three regimes: a low, an intermediate and a high swirling regime. The pressure field of the low swirling regime is the superposition of the pressure field of the non-swirling jet and a swirl induced pressure field due to the centrifugal forces of the rotating jet. As the swirl increases, the swirl induced pressure field becomes dominant and for the intermediate and high swirling regimes, the simple radial equilibrium equation holds.

  15. Planar Pressure Field Determination in the Initial Merging Zone of an Annular Swirling Jet Based on Stereo-PIV Measurements.

    Science.gov (United States)

    Vanierschot, Maarten; Van den Bulck, Eric

    2008-11-28

    In this paper the static pressure field of an annular swirling jet is measured indirectly using stereo-PIV measurements. The pressure field is obtained from numerically solving the Poisson equation, taken into account the axisymmetry of the flow. At the boundaries no assumptions are made and the exact boundary conditions are applied. Since all source terms can be measured using stereo-PIV and the boundary conditions are exact, no assumptions other than axisymmetry had to be made in the calculation of the pressure field. The advantage of this method of indirect pressure measurement is its high spatial resolution compared to the traditional pitot probes. Moreover this method is non-intrusive while the insertion of a pitot tube disturbs the flow. It is shown that the annular swirling flow can be divided into three regimes: a low, an intermediate and a high swirling regime. The pressure field of the low swirling regime is the superposition of the pressure field of the non-swirling jet and a swirl induced pressure field due to the centrifugal forces of the rotating jet. As the swirl increases, the swirl induced pressure field becomes dominant and for the intermediate and high swirling regimes, the simple radial equilibrium equation holds.

  16. Basic principles for measurement of intramuscular pressure

    Science.gov (United States)

    Hargens, A. R.; Ballard, R. E.

    1995-01-01

    We review historical and methodological approaches to measurements of intramuscular pressure (IMP) in humans. These techniques provide valuable measures of muscle tone and activity as well as diagnostic criteria for evaluation of exertional compartment syndrome. Although the wick and catheter techniques provide accurate measurements of IMP at rest, their value for exercise studies and diagnosis of exertional compartment syndrome is limited because of low frequency response and hydrostatic (static and inertial) pressure artifacts. Presently, most information on diagnosis of exertional compartment syndromes during dynamic exercise is available using the Myopress catheter. However, future research and clinical diagnosis using IMP can be optimized by the use of a miniature transducer-tipped catheter such as the Millar Mikro-tip.

  17. Fracture-specific pressure measurements at the Olkiluoto site in Eurajoki drillhole OL-KR39

    International Nuclear Information System (INIS)

    Ripatti, K.; Poellaenen, J.; Hurmerinta, E.; Rouhiainen, P.

    2011-12-01

    An option was built to the Posiva Flow Log, Difference flow method (PFL DIFF). A double packer device was combined together with a PFL DIFF probe. The new tool was needed for measurements of the very low hydraulic head. Indications of these were detected earlier in some fractures of drillhole OL-KR39. The target fractures could be measured with the accurate absolute pressure sensor in the PFL DIFF probe. Principles of the methods and the results of measurements are presented in this report. The measurements were carried out in drillhole OL-KR39 at the Olkiluoto investigation site between April 2011 and May 2011. The device used includes a sensor for single point resistance (SPR). SPR measurement is used to place the device accurately on the chosen fracture. The section length limited by the packers is about 1 m. The measurements were carried out in natural (i.e. un-pumped) conditions. The same measuring program was employed in all chosen fractures. Electrical conductivity (EC) of drillhole water and flow rate along the drillhole were also measured in conjunction with the pressure measurements. (orig.)

  18. Flight Investigation at High Mach Numbers of Several Methods of Measuring Static Pressure on an Airplane Wing

    Science.gov (United States)

    1944-11-01

    SS SUBJECT HEADIN6S: Pressure distribution - Flow research - Methods (40950) Wings (74500); DMiion, Intolilfjonco Air Kkrtcricl Command AIQ TECHNICAL INDGK Wrl0ht- Patto *son Air Forco ( Dayton, Ohio ///¥

  19. Partial pressure measurements with an active spectrometer

    International Nuclear Information System (INIS)

    Brooks, N.H.; Jensen, T.H.; Colchin, R.J.; Maingi, R.; Wade, M.R.; Finkenthal, D.F.; Naumenko, N.; Tugarinov, S.

    1998-07-01

    Partial pressure neutral ga measurements have been made using a commercial Penning gauge in conjunction with an active spectrometer. In prior work utilizing bandpass filters and conventional spectrometers, trace concentrations of the hydrogen isotopes H, D, T and of the noble gases He, Ne and Ar were determined from characteristic spectral lines in the light emitted by the neutral species of these elements. For all the elements mentioned, the sensitivity was limited by spectral contamination from a pervasive background of molecular hydrogen radiation. The active spectrometer overcomes this limitations by means of a digital lock-in method and correlation with reference spectra. Preliminary measurements of an admixture containing a trace amount of neon in deuterium show better than a factor of 20 improvement in sensitivity over conventional techniques. This can be further improved by correlating the relative intensities of multiple lines to sets of reference spectra

  20. Non-invasive continuous finger blood pressure measurement during orthostatic stress compared to intra-arterial pressure

    NARCIS (Netherlands)

    Imholz, B. P.; Settels, J. J.; van der Meiracker, A. H.; Wesseling, K. H.; Wieling, W.

    1990-01-01

    The aim of the study was to evaluate whether invasive blood pressure responses to orthostatic stress can be replaced by non-invasive continuous finger blood pressure responses. DESIGN - Intrabrachial and Finapres blood pressures were simultaneously measured during passive head up tilt and during

  1. Study on Method of Ultrasonic Gas Temperature Measure Based on FPGA

    Energy Technology Data Exchange (ETDEWEB)

    Wen, S H; Xu, F R [Institute of Electrical Engineering, Yanshan University, Qinhuangdao, 066004 (China)

    2006-10-15

    It is always a problem to measure instantaneous temperature of high-temperature and high-pressure gas. There is difficulty for the conventional method of measuring temperature to measure quickly and exactly, and the measuring precision is low, the ability of anti-jamming is bad, etc. So the article introduces a method of measuring burning gas temperature using ultrasonic based on Field-Programmable Gate Array (FPGA). The mathematic model of measuring temperature is built with the relation of velocity of ultrasonic transmitting and gas Kelvin in the ideal gas. The temperature can be figured out by measuring the difference of ultrasonic frequency {delta}f. FPGA is introduced and a high-precision data acquisition system based on digital phase-shift technology is designed. The feasibility of proposed above is confirmed more by measuring pressure of burning gas timely. Experimental result demonstrates that the error is less than 12.. and the precision is heightened to 0.8%.

  2. A Direct inverse model to determine permeability fields from pressure and flow rate measurements

    NARCIS (Netherlands)

    Brouwer, G.K.; Fokker, P.A.; Wilschut, F.; Zijl, W.

    2008-01-01

    The determination of the permeability field from pressure and flow rate measurements in wells is a key problem in reservoir engineering. This paper presents a Double Constraint method for inverse modeling that is an example of direct inverse modeling. The method is used with a standard

  3. Joint reconstruction of the initial pressure and speed of sound distributions from combined photoacoustic and ultrasound tomography measurements

    Science.gov (United States)

    Matthews, Thomas P.; Anastasio, Mark A.

    2017-12-01

    The initial pressure and speed of sound (SOS) distributions cannot both be stably recovered from photoacoustic computed tomography (PACT) measurements alone. Adjunct ultrasound computed tomography (USCT) measurements can be employed to estimate the SOS distribution. Under the conventional image reconstruction approach for combined PACT/USCT systems, the SOS is estimated from the USCT measurements alone and the initial pressure is estimated from the PACT measurements by use of the previously estimated SOS. This approach ignores the acoustic information in the PACT measurements and may require many USCT measurements to accurately reconstruct the SOS. In this work, a joint reconstruction method where the SOS and initial pressure distributions are simultaneously estimated from combined PACT/USCT measurements is proposed. This approach allows accurate estimation of both the initial pressure distribution and the SOS distribution while requiring few USCT measurements.

  4. Challenges in standardization of blood pressure measurement at the population level.

    Science.gov (United States)

    Tolonen, Hanna; Koponen, Päivikki; Naska, Androniki; Männistö, Satu; Broda, Grazyna; Palosaari, Tarja; Kuulasmaa, Kari

    2015-04-10

    Accurate blood pressure measurements are needed in clinical practice, intervention studies and health examination surveys. Blood pressure measurements are sensitive: their accuracy can be affected by measurement environment, behaviour of the subject, measurement procedures, devices used for the measurement and the observer. To minimize errors in blood pressure measurement, a standardized measurement protocol is needed. The European Health Examination Survey (EHES) Pilot project was conducted in 2009-2012. A pilot health examination survey was conducted in 12 countries using a standardized protocol. The measurement protocols used in each survey, training provided for the measurers, measurement data, and observations during site visits were collected and evaluated to assess the level of standardization. The EHES measurement protocol for blood pressure was followed accurately in all 12 pilot surveys. Most of the surveys succeeded in organizing a quiet and comfortable measurement environment, and staff instructed survey participants appropriately before examination visits. In all surveys, blood pressure was measured three times, from the right arm in a sitting posture. The biggest variation was in the device used for the blood pressure measurement. It is possible to reach a high level of standardization for blood pressure measurements across countries and over time. A detailed, standardized measurement protocol, and adequate training and monitoring during the fieldwork and centrally organized quality assessment of the data are needed. The recent EU regulation banning the sale of mercury sphygmomanometer in European Union Member States has set new challenges for the standardization of measurement devices since the validity of oscillometric measurements is device-specific and performance of aneroid devices depends very much on calibration.

  5. Differential Intracochlear Sound Pressure Measurements in Normal Human Temporal Bones

    Science.gov (United States)

    Nakajima, Hideko Heidi; Dong, Wei; Olson, Elizabeth S.; Merchant, Saumil N.; Ravicz, Michael E.; Rosowski, John J.

    2009-02-01

    We present the first simultaneous sound pressure measurements in scala vestibuli and scala tympani of the cochlea in human cadaveric temporal bones. Micro-scale fiberoptic pressure sensors enabled the study of differential sound pressure at the cochlear base. This differential pressure is the input to the cochlear partition, driving cochlear waves and auditory transduction. Results showed that: pressure of scala vestibuli was much greater than scala tympani except at low and high frequencies where scala tympani pressure affects the input to the cochlea; the differential pressure proved to be an excellent measure of normal ossicular transduction of sound (shown to decrease 30-50 dB with ossicular disarticulation, whereas the individual scala pressures were significantly affected by non-ossicular conduction of sound at high frequencies); the middle-ear gain and differential pressure were generally bandpass in frequency dependence; and the middle-ear delay in the human was over twice that of the gerbil. Concurrent stapes velocity measurements allowed determination of the differential impedance across the partition and round-window impedance. The differential impedance was generally resistive, while the round-window impedance was consistent with a compliance in conjunction with distributed inertia and damping. Our techniques can be used to study inner-ear conductive pathologies (e.g., semicircular dehiscence), as well as non-ossicular cochlear stimulation (e.g., round-window stimulation) - situations that cannot be completely quantified by measurements of stapes velocity or scala-vestibuli pressure by themselves.

  6. Radiation Pressure Measurements on Micron Size Individual Dust Grains

    Science.gov (United States)

    Abbas, M. M.; Craven, P.D.; Spann, J. F.; Tankosic, D.; Witherow, W. K.; LeClair, A.; West, E.; Sheldon, R.; Gallagher, D. L.; Adrian, M. L.

    2003-01-01

    Measurements of electromagnetic radiation pressure have been made on individual silica (SiO2) particles levitated in an electrodynamic balance. These measurements were made by inserting single charged particles of known diameter in the 0.2 micron to 6.82 micron range and irradiating them from above with laser radiation focused to beam-widths of approx. 175-400 micron, at ambient pressures approx. 10(exp -3) to 10(exp -4) torr. The downward displacement of the particle due to the radiation force is balanced by the electrostatic force indicated by the compensating dc potential applied to the balance electrodes, providing a direct measure of the radiation force on the levitated particle. Theoretical calculations of the radiation pressure with a least-squares fit to the measured data yield the radiation pressure efficiencies of the particles, and comparisons with Mie scattering theory calculations provide the imaginary part of the refractive index of silica and the corresponding extinction and scattering efficiencies.

  7. Blood pressure measurements in the ankle are not equivalent to blood pressure measurements in the arm.

    Science.gov (United States)

    Goldstein, Lara Nicole; Wells, Mike; Sliwa, Karen

    2014-07-25

    Blood pressure (BP) is often measured on the ankle in the emergency department (ED), but this has never been shown to be an acceptable alternative to measurements performed on the arm. To establish whether the differences between arm and ankle non-invasive BP measurements were clinically relevant (i.e. a difference of ≥10 mmHg). This was a prospective cross-sectional study in an urban ED making use of a convenience sample of 201 patients (18 - 50 years of age) who were not in need of emergency medical treatment. BP was measured in the supine position on both arms and ankles with the correct size cuff according to the manufacturer's guidelines. The arm and ankle BP measurements were compared. There was a clinically and statistically significant difference between arm and ankle systolic BP (SBP) and mean arterial pressure (MAP) (-13 mmHg, 95% confidence interval (CI) -28 - 1 mmHg and -5 mmHg, 95% CI -13 - 4 mmHg, respectively), with less difference in diastolic BP (DBP) (2 mmHg, 95% CI -7 - 10 mmHg). Only 37% of SBP measurements and 83% of MAP measurements were within an error range of 10 mmHg, while 95% of DBP measurements agreed within 10 mmHg. While the average differences (or the bias) were generally not large, large variations in individual patients (indicating poor precision) made the prediction of arm BP from ankle measurements unreliable. Ankle BP cannot be used as a substitute for arm BP in the ED.

  8. Measurement of small values of hydrostatic pressure difference / Pomiar małych wartości różnicy ciśnień hydrostatycznych

    Science.gov (United States)

    Broda, Krzysztof; Filipek, Wiktor

    2012-10-01

    In order to describe the fluid flow through the porous centre, made of identical spheres, it is necessary to know the pressure, but in fact - the pressure distribution. For the flows in the range that was traditionally called laminar flow (i. e. for Reynolds numbers (Bear, 1988; Duckworth, 1983; Troskolański, 1957) from the range 0,01 to 3) it is virtually impossible with the use of the tools directly available on the market. Therefore, many scientists who explore this problem have concentrated only on the research of the velocity distribution of the medium that penetrates the intended centre (Bear, 1988) or pressure distribution at high hydraulic gradients (Trzaska & Broda, 1991, 2000; Trzaska et al., 2005). It may result from the inaccessibility to the measurement methods that provide measurement of very low hydrostatic pressures, such as pressure resulting from the weight of liquid located in the gravitational field (Duckworth, 1983; Troskolański, 1957). The pressure value c. 10 Pa (Troskolański, 1957) can be generated even by 1 mm height difference between the two levels of the free water surface, which in fact constitutes the definition of gauging tools of today measuring the level of the hydrostatic pressure. Authors proposed a method of hydrostatic pressure measurement and devised a gauging tool. Then a series of tests was conducted aiming at establishing what is the influence of various factors, such as temperature, atmospheric pressure, velocity of measurement completion, etc. on the accuracy and method of measurements. A method for considerable reduction of hysteresis that occurs during measurement was also devised. The method of measurement of small hydrostatic difference measurements allows for the accuracy of measurement of up to 0.5 Pa. Measurement results can be improved successfully by one order of magnitude, which for sure would entail necessary temperature stabilization of the tool. It will be more difficult though to compensate the influence

  9. Pressure vessels and methods of sealing leaky tubes disposed in pressure vessels

    International Nuclear Information System (INIS)

    Larson, G.C.

    1980-01-01

    This invention relates to pressure vessels and to methods of sealing leaky tubes in them and is especially applicable to pressure vessels in the form of sheet-and-tube type heat exchangers constructed with a large number of relatively small diameter tubes grouped in a bundle. To seal off a leaky tube in such a heat exchanger an explosive activated plug in the form of a hollow metal body is used, inserted at each end of the tube to be sealed. Using the arrangement of pressure vessel and associated tube sheets and the explosive activated plug method of sealing a leaky tube as described in this invention it is claimed that distortion of the adjacent tubes and the tube sheets is reduced when the explosive activated plugs are detonated. (U.K.)

  10. A reference data set for validating vapor pressure measurement techniques: homologous series of polyethylene glycols

    Science.gov (United States)

    Krieger, Ulrich K.; Siegrist, Franziska; Marcolli, Claudia; Emanuelsson, Eva U.; Gøbel, Freya M.; Bilde, Merete; Marsh, Aleksandra; Reid, Jonathan P.; Huisman, Andrew J.; Riipinen, Ilona; Hyttinen, Noora; Myllys, Nanna; Kurtén, Theo; Bannan, Thomas; Percival, Carl J.; Topping, David

    2018-01-01

    To predict atmospheric partitioning of organic compounds between gas and aerosol particle phase based on explicit models for gas phase chemistry, saturation vapor pressures of the compounds need to be estimated. Estimation methods based on functional group contributions require training sets of compounds with well-established saturation vapor pressures. However, vapor pressures of semivolatile and low-volatility organic molecules at atmospheric temperatures reported in the literature often differ by several orders of magnitude between measurement techniques. These discrepancies exceed the stated uncertainty of each technique which is generally reported to be smaller than a factor of 2. At present, there is no general reference technique for measuring saturation vapor pressures of atmospherically relevant compounds with low vapor pressures at atmospheric temperatures. To address this problem, we measured vapor pressures with different techniques over a wide temperature range for intercomparison and to establish a reliable training set. We determined saturation vapor pressures for the homologous series of polyethylene glycols (H - (O - CH2 - CH2)n - OH) for n = 3 to n = 8 ranging in vapor pressure at 298 K from 10-7 to 5×10-2 Pa and compare them with quantum chemistry calculations. Such a homologous series provides a reference set that covers several orders of magnitude in saturation vapor pressure, allowing a critical assessment of the lower limits of detection of vapor pressures for the different techniques as well as permitting the identification of potential sources of systematic error. Also, internal consistency within the series allows outlying data to be rejected more easily. Most of the measured vapor pressures agreed within the stated uncertainty range. Deviations mostly occurred for vapor pressure values approaching the lower detection limit of a technique. The good agreement between the measurement techniques (some of which are sensitive to the mass

  11. Magnetic resonance measurement of turbulent kinetic energy for the estimation of irreversible pressure loss in aortic stenosis.

    Science.gov (United States)

    Dyverfeldt, Petter; Hope, Michael D; Tseng, Elaine E; Saloner, David

    2013-01-01

    The authors sought to measure the turbulent kinetic energy (TKE) in the ascending aorta of patients with aortic stenosis and to assess its relationship to irreversible pressure loss. Irreversible pressure loss caused by energy dissipation in post-stenotic flow is an important determinant of the hemodynamic significance of aortic stenosis. The simplified Bernoulli equation used to estimate pressure gradients often misclassifies the ventricular overload caused by aortic stenosis. The current gold standard for estimation of irreversible pressure loss is catheterization, but this method is rarely used due to its invasiveness. Post-stenotic pressure loss is largely caused by dissipation of turbulent kinetic energy into heat. Recent developments in magnetic resonance flow imaging permit noninvasive estimation of TKE. The study was approved by the local ethics review board and all subjects gave written informed consent. Three-dimensional cine magnetic resonance flow imaging was used to measure TKE in 18 subjects (4 normal volunteers, 14 patients with aortic stenosis with and without dilation). For each subject, the peak total TKE in the ascending aorta was compared with a pressure loss index. The pressure loss index was based on a previously validated theory relating pressure loss to measures obtainable by echocardiography. The total TKE did not appear to be related to global flow patterns visualized based on magnetic resonance-measured velocity fields. The TKE was significantly higher in patients with aortic stenosis than in normal volunteers (p < 0.001). The peak total TKE in the ascending aorta was strongly correlated to index pressure loss (R(2) = 0.91). Peak total TKE in the ascending aorta correlated strongly with irreversible pressure loss estimated by a well-established method. Direct measurement of TKE by magnetic resonance flow imaging may, with further validation, be used to estimate irreversible pressure loss in aortic stenosis. Copyright © 2013 American

  12. Results of pressurized-slot measurements in the G-Tunnel underground facility

    International Nuclear Information System (INIS)

    Zimmerman, R.M.; Mann, K.L.; Dodds, D.J.

    1989-01-01

    A rock-mechanics field-testing program is underway at Sandia National Laboratories (SNL) as part of the YMP. SNL has the responsibility for assessing the repository design and performance as well as characterizing the geomechanical behavior of the rock. SNL has conducted field experiments in G-Tunnel in Rainier Mesa at the NTS, where tuffs similar to those at Yucca Mountain, the potential repository site, are found. Later experiments are planned as part of the YMP Exploratory Shaft investigations at Yucca Mountain. Major geomechanical factors in repository developments are determinations of the stress state and the deformability of the rock mass (described by the modulus of deformation). One feature of SNL's rock-mechanics program was the development of a testing program for cutting thin slots in a jointed welded tuff and utilizing flatjacks for pressurizing these thin-slots on a relatively, large scale. Objectives in the pressurized-slot testing in G-Tunnel have been to apply and possibly improve methods for (1) utilizing the flatjack cancellation (FC) method for measuring stresses normal to the slot and (2) measuring the modulus of deformation of the jointed rock surrounding the slot. This paper discusses the results of field measurements in and around a single slot and evaluates potential applications and limitations. 10 refs., 1 fig., 4 tabs

  13. Sensing line effects on PWR-based differential pressure measurements

    International Nuclear Information System (INIS)

    Evans, R.P.; Neff, G.G.

    1982-01-01

    An incorrrect configuration of the fluid-filled pressure sensing lines connecting differential pressure transducers to the pressure taps in a pressurized water reactor system can cause errors in the measurement and, during rapid pressure transients, could cause the transducer to fail. Testing was performed in both static and dynamic modes to experimentally determine the effects of sensing lines of various lengths, diameters, and materials. Testing was performed at ambient temperature with absolute line pressures at about 17 MPa using water as the pressure transmission fluid

  14. A gas thermometer for vapor pressure measurements

    Science.gov (United States)

    Rusin, A. D.

    2008-08-01

    The pressure of an inert gas over the range 400 1000 K was measured on a tensimetric unit with a quartz membrane pressure gauge of enhanced sensitivity. It was shown that a reactor with a membrane null gauge could be used as a gas thermometer. The experimental confidence pressure and temperature intervals were 0.07 torr and 0.1 K at a significance level of 0.05. A Pt-Pt/10% Rh thermocouple was calibrated; the results were approximated by a polynomial of degree five. The error in temperature calculations was 0.25 K.

  15. Identification of defluidization region in a gas-solid fluidized bed using a method based on pressure fluctuation measurements

    Directory of Open Access Journals (Sweden)

    M. R. Parise

    2009-09-01

    Full Text Available Industrial applications that involve fluidized bed operations must prevent the undesirable phenomenon of partial or complete bed defluidization. Defluidization can be avoided by increasing the gas velocity and/or, in some cases, changing the solid feed conditions in the system, provided that the changes in the hydrodynamics of the flow are detected early enough. The use of a technique that can perform an early detection of the defluidization condition in industrial applications is important, in order to avoid the loss of efficiency or even an undesirable shutting down of the process. The objective of this work is to show the application of a method for early detection of the condition where the bed is tending to the defluidization, in a gas-solid fluidized bed flow. The method is based on pressure fluctuation measurements. Experimental tests are carried out using two solid particles: microcrystalline cellulose and sand. Results show that the proposed method is efficient in detecting the fluidization condition in a conventional bubbling bed regime. The potential of application of the technique is also shown for the control of the defluidization phenomenon in industry.

  16. Tandem-Mirror Experiment-Upgrade neutral pressure measurement diagnostic systems

    International Nuclear Information System (INIS)

    Pickles, W.L.; Allen, S.L.; Hill, D.N.; Hunt, A.L.; Simonen, T.C.

    1985-01-01

    The Tandem-Mirror Experiment-Upgrade (TMX-U) has a large and complex system of Bayard--Alpert, magnetron, and Penning gauges, in addition to mass spectrometers (RGA), all of which measure neutral pressures in the many internal regions of TMX-U. These pressure measurements are used as part of the confinement physics data base as well as for management of the TMX-U vacuum system. Dynamic pressures are modeled by a coupled-volumes simulation code, which includes wall reflux, getter pumping, and plasma pumping

  17. The Increase of Intra-Abdominal Pressure Can Affect Intraocular Pressure

    Directory of Open Access Journals (Sweden)

    Ilhan Ece

    2015-01-01

    Full Text Available Objective. This study aims to explore the usage of intraocular pressure measurements as the early indicator of the increase in intra-abdominal pressure. Methods. In this prospective study, 40 patients undergoing elective surgery were included. Patients were divided into four groups of 10 patients. The control group (Group C was not subjected to laparoscopic intervention. Laparoscopic surgery was, respectively, performed with an intra-abdominal pressure of 9, 12, and 15 mmHg in Groups L (low, M (medium, and H (high pressure. Intraocular pressure was measured binocularly in each patient at three different times (before, during, and end of surgery using a contact tonometer. Results. Patients’ gender, age, body mass index (BMI, American Society of Anesthesiology (ASA class, and operative times were not different among the groups. No complications occurred with either the surgery or measurement of intraocular pressure. Intubation was associated with a severe rise in IOP (P<0.05. An increase in intraocular pressure was seen in groups M and H (P<0.05. Conclusion. Intraocular pressure was increased in the groups with an intra-abdominal pressure of 12 mmHg or more. Measuring the intraocular pressure might be a useful method to estimate the intra-abdominal pressure. This trial is registered with NCT02319213.

  18. CORRELATION OF INTRAOCULAR PRESSURE MEASUREMENTS WITH NON CONTACT TONOMETER AND GOLDMANN APPLANATION TONOMETRY

    Directory of Open Access Journals (Sweden)

    Leya Sara George

    2017-07-01

    Full Text Available BACKGROUND A complete ophthalmologic examination includes intraocular pressure (IOP measurement, which is a routine procedure and is important for diagnosis and monitoring of glaucoma. IOP measurement is most commonly done using Goldmann Applanation tonometer and Non-Contact tonometer. MATERIALS AND METHODS In this study IOP measurements of 500 eyes (glaucomatous and non-glaucomatous were performed using GAT and NCT on patients visiting the outpatient clinic of Department of Ophthalmology at Christian Medical College and Hospital, Ludhiana. This was a cross sectional and observational study. Comparison of IOP values was done in different IOP ranges. CCT was measured and analysis of its correlation with GAT and NCT was done. RESULTS Both methods of tonometry correlated significantly in patients with IOP <24 mm Hg. The mean IOP measured by NCT, was 16.06 ± 5.85 mm Hg and the mean IOP measurement by GAT was 16.61 ± 6.94 mm Hg. Intraocular pressure readings with GAT and NCT positively correlated with CCT. CONCLUSION NCT may be useful for screening in clinical settings but borderline high IOP readings should be confirmed with GAT. Our findings, also suggest that CCT is an essential variable to consider in interpreting IOP readings.

  19. Reliability of Eustachian tube function measurements in a hypobaric and hyperbaric pressure chamber.

    Science.gov (United States)

    Meyer, M F; Jansen, S; Mordkovich, O; Hüttenbrink, K-B; Beutner, D

    2017-12-01

    Measurement of the Eustachian tube (ET) function is a challenge. The demand for a precise and meaningful diagnostic tool increases-especially because more and more operative therapies are being offered without objective evidence. The measurement of the ET function by continuous impedance recording in a pressure chamber is an established method, although the reliability of the measurements is still unclear. Twenty-five participants (50 ears) were exposed to phases of compression and decompression in a hypo- and hyperbaric pressure chamber. The ET function reflecting parameters-ET opening pressure (ETOP), ET opening duration (ETOD) and ET opening frequency (ETOF)-were determined under exactly the same preconditions three times in a row. The intraclass correlation coefficient (ICC) and Bland and Altman plot were used to assess test-retest reliability. ICCs revealed a high correlation for ETOP and ETOF in phases of decompression (passive equalisation) as well as ETOD and ETOP in phases of compression (active induced equalisation). Very high correlation could be shown for ETOD in decompression and ETOF in compression phases. The Bland and Altman graphs could show that measurements provide results within a 95 % confidence interval in compression and decompression phases. We conclude that measurements in a pressure chamber are a very valuable tool in terms of estimating the ET opening and closing function. Measurements show some variance comparing participants, but provide reliable results within a 95 % confidence interval in retest. This study is the basis for enabling efficacy measurements of ET treatment modalities. © 2017 John Wiley & Sons Ltd.

  20. Methods of viscosity measurements in sealed ampoules

    Science.gov (United States)

    Mazuruk, Konstantin

    1999-07-01

    Viscosity of semiconductors and metallic melts is usually measured by oscillating cup method. This method utilizes the melts contained in vacuum sealed silica ampoules, thus the problems related to volatility, contamination, and high temperature and pressure can be alleviate. In a typical design, the time required for a single measurement is of the order of one hour. In order to reduce this time to a minute range, a high resolution angular detection system is implemented in our design of the viscometer. Furthermore, an electromagnet generating a rotational magnetic field (RMF) is incorporated into the apparatus. This magnetic field can be used to remotely and nonintrusively measure the electrical conductivity of the melt. It can also be used to induce a well controlled rotational flow in the system. The transient behavior of this flow can potentially yield of the fluid. Based on RMF implementation, two novel viscometry methods are proposed in this work: a) the transient torque method, b) the resonance method. A unified theoretical approach to the three methods is presented along with the initial test result of the constructed apparatus. Advantages of each of the method are discussed.

  1. Measurement of local void fraction at elevated temperature and pressure

    International Nuclear Information System (INIS)

    Duncan, D.; Trabold, T.A.

    1993-03-01

    Significant advances have recently been made in analytical and computational methods for the prediction of local thermal-hydraulic conditions in gas/liquid two-phase flows. There is, however, a need for extensive experimental data, for the dual purposes of constitutive relation development and code qualification. There is especially true of systems involving complicated geometries and/or extreme flow conditions for which little, if any, applicable information exists in the open literature. For the tests described in the present paper, a novel electrical probe has been applied to measure the void fraction in atmospheric pressure air/water flows, and steam/water mixtures at high temperature and pressure. The data acquired in the latter experiments are compared with the results of a one-dimensional two-fluid computational analysis

  2. Measures of total stress-induced blood pressure responses are associated with vascular damage.

    Science.gov (United States)

    Nazzaro, Pietro; Seccia, Teresa; Vulpis, Vito; Schirosi, Gabriella; Serio, Gabriella; Battista, Loredana; Pirrelli, Anna

    2005-09-01

    The role of cardiovascular reactivity to study hypertension, and the assessment methods, are still controversial. We aimed to verify the association of hypertension and vascular damage with several measures of cardiovascular response. We studied 40 patients with normal-high (132 +/- 1/87 +/- 1 mm Hg) blood pressure (Group 1) and 80 untreated hypertensive subjects. Postischemic forearm vascular resistance (mFVR) served to differentiate hypertensive subjects (142 +/- 2/92 +/- 1 mm Hg v 143 +/- 2/94 +/- 2 mm Hg, P = NS) with a lower (Group 2) and higher (Group 3) hemodynamic index of vascular damage (4.8 +/- .05 v 6.3 +/- .09, P blood pressure, heart rate, forearm blood flow, and vascular resistance. Reactivity measures included: a) change from baseline, b) residualized score, c) cumulative change from baseline and residualized score, and d) total reactivity as area-under-the-curve (AUC), including changes occurring during baseline and recovery phases. The AUC of systolic blood pressure, diastolic blood pressure, and mFVR progressively increased in the groups (P AUC of SBP, DBP, and forearm blood flow and resistance demonstrated the highest (P AUC of SBP (beta = 0.634) and forearm blood flow (beta = -0.337) were predictive (P blood pressure stress response, as AUC, including baseline and recovery phases, was significantly better associated with hypertension and vascular damage than the other reactivity measures studied.

  3. Direct measurement of the wetting front capillary pressure in a clay brick ceramic

    Energy Technology Data Exchange (ETDEWEB)

    Ioannou, Ioannis [Manchester Centre for Civil and Construction Engineering, UMIST, PO Box 88, Manchester M60 1QD (United Kingdom); Hall, Christopher [Centre for Materials Science and Engineering and School of Engineering and Electronics, University of Edinburgh, The King' s Buildings, Edinburgh EH9 3JL (United Kingdom); Wilson, Moira A [Manchester Centre for Civil and Construction Engineering, UMIST, PO Box 88, Manchester M60 1QD (United Kingdom); Hoff, William D [Manchester Centre for Civil and Construction Engineering, UMIST, PO Box 88, Manchester M60 1QD (United Kingdom); Carter, Margaret A [Manchester Centre for Civil and Construction Engineering, UMIST, PO Box 88, Manchester M60 1QD (United Kingdom)

    2003-12-21

    The absorption of a liquid into a rectangular bar of an initially dry porous material that is sealed on all surfaces except the inflow face is analysed in terms of Sharp Front theory. Sharp Front models are developed for both complete and incomplete displacement of air ahead of the advancing wetting front. Experiments are described from which a characteristic capillary potential of the material is obtained by measuring the equilibrium pressure of the air displaced and compressed ahead of the advancing wetting front. Results for the absorption of water and n-heptane by a fired clay brick ceramic suggest that this wetting front capillary pressure (or capillary potential) scales approximately with the surface tension and also that the permeability scales inversely with the liquid viscosity. The pressure of the air trapped in the wetted region is found to be the same as the pressure of the displaced air. For this material the wetting front capillary pressure for water at 20 C is 0.113 MPa, equivalent to a hydraulic tension head of 11.5 m and to a Young-Laplace pore diameter of 2.6 {mu}m. The capillary pressure so measured is apparently a fundamental percolation property of the material that can be interpreted as the air pressure at which liquid phase continuity and unsaturated conductivity both vanish. The method described can be applied generally to porous materials.

  4. Direct measurement of the wetting front capillary pressure in a clay brick ceramic

    International Nuclear Information System (INIS)

    Ioannou, Ioannis; Hall, Christopher; Wilson, Moira A; Hoff, William D; Carter, Margaret A

    2003-01-01

    The absorption of a liquid into a rectangular bar of an initially dry porous material that is sealed on all surfaces except the inflow face is analysed in terms of Sharp Front theory. Sharp Front models are developed for both complete and incomplete displacement of air ahead of the advancing wetting front. Experiments are described from which a characteristic capillary potential of the material is obtained by measuring the equilibrium pressure of the air displaced and compressed ahead of the advancing wetting front. Results for the absorption of water and n-heptane by a fired clay brick ceramic suggest that this wetting front capillary pressure (or capillary potential) scales approximately with the surface tension and also that the permeability scales inversely with the liquid viscosity. The pressure of the air trapped in the wetted region is found to be the same as the pressure of the displaced air. For this material the wetting front capillary pressure for water at 20 C is 0.113 MPa, equivalent to a hydraulic tension head of 11.5 m and to a Young-Laplace pore diameter of 2.6 μm. The capillary pressure so measured is apparently a fundamental percolation property of the material that can be interpreted as the air pressure at which liquid phase continuity and unsaturated conductivity both vanish. The method described can be applied generally to porous materials

  5. A novel polarization demodulation method using polarization beam splitter (PBS) for dynamic pressure sensor

    Science.gov (United States)

    Su, Yang; Zhou, Hua; Wang, Yiming; Shen, Huiping

    2018-03-01

    In this paper we propose a new design to demodulate polarization properties induced by pressure using a PBS (polarization beam splitter), which is different with traditional polarimeter based on the 4-detector polarization measurement approach. The theoretical model is established by Muller matrix method. Experimental results confirm the validity of our analysis. Proportional relationships and linear fit are found between output signal and applied pressure. A maximum sensitivity of 0.092182 mv/mv is experimentally achieved and the frequency response exhibits a <0.14 dB variation across the measurement bandwidth. The sensitivity dependence on incident SOP (state of polarization) is investigated. The simple and all-fiber configuration, low-cost and high speed potential make it promising for fiber-based dynamic pressure sensing.

  6. Proportion and characteristics of patients who measure their blood pressure at home: Nationwide survey in Slovenia

    Directory of Open Access Journals (Sweden)

    Petek-Šter Marija

    2009-01-01

    Full Text Available Introduction. Home blood pressure monitoring has several advantages over blood pressure monitoring at a physician's office, and has become a useful instrument in the management of hypertension. Objective. To explore the rate and characteristics of patients who measure their blood pressure at home. Methods. A sample of 2,752 patients with diagnosis of essential arterial hypertension was selected from 12596 consecutive office visitors. Data of 2,639 patients was appropriate for analysis. The data concerning home blood pressure measurement and patients' characteristics were obtained from the patients' case histories. Results 1,835 (69.5% out of 2,639 patients measured their blood pressure at home. 1,284 (70.0% of home blood pressure patients had their own blood pressure measurement device. There were some important differences between these two groups: home blood pressure patients were more frequently male, of younger age, better educated, from urban area, mostly non-smokers, more likely to have diabetes mellitus and ischemic heart disease and had higher number of co-morbidities and were on other drugs beside antihypertensive medication. Using the logistic regression analysis we found that the most powerful predictors of home blood pressure monitoring had higher education level than primary school OR=1.80 (95% CI 1.37-2.37, non-smoking OR=2.16 (95% CI 1.40-3.33 and having a physician in urban area OR=1.32 (95% CI 1.02-1.71. Conclusion. Home blood pressure monitoring is popular in Slovenia. Patients who measured blood pressure at home were different from patients who did not. Younger age, higher education, non-smoking, having a physician in urban area and longer duration of hypertension were predictors of home blood pressure monitoring.

  7. Measuring the osmotic pressure of active colloids

    Science.gov (United States)

    Wang, Michael; Soni, Vishal; Magkiriadou, Sofia; Ferrari, Melissa; Youssef, Mina; Driscoll, Michelle; Sacanna, Stefano; Chaikin, Paul; Irvine, William

    We study the behavior of a system of colloidal spinners, consisting of weakly magnetic colloids driven by a rotating magnetic field. First the particles are allowed to sediment to an equilibrium density profile in a gravitational field, from which we measure the equilibrium equation of state. By spinning the particles at various frequencies, we introduce activity into the system through the hydrodynamic interactions between particles. We observe that the activity expands the sedimentation profile to a new steady state, from which we measure the pressure as a function of the density and activity. We compare the effects of activity on the pressure and mean-squared displacement of spinners and tracer particles.

  8. Method of repairing pressure tube type reactors

    International Nuclear Information System (INIS)

    Asada, Takashi.

    1983-01-01

    Purpose: To enable to re-start the reactor operation in a short time, upon occurrence of failures in a pressure tube, as well as directly examine the cause for the failures in the pressure tube. Method: The pressure tube reactor main body comprises a calandria tank of a briquette form, pressure tubes, fuel assemblies and an iron-water shielding body. If failure is resulted to a pressure tube, the reactor operation is at first shutdown and nuclear fuel assemblies are extracted to withdraw from the pressure tube. Then, to an inlet pipe way and an outlet pipeway connected to the failed pressure tube, are attached plugs by means of welding or the like at the appropriate position where the radiation exposure dose is lower and the repairing work can be performed with ease. The pressure tube is disconnected to withdraw from the inlet pipeway and the outlet pipeway and, instead, radiation shielding plug tube is inserted and shield cooling device is actuated if required, wherein the reactor is actuated to re-start the operation. (Yoshino, Y.)

  9. Community-based blood pressure measurement by non-health workers using electronic devices: a validation study

    Directory of Open Access Journals (Sweden)

    Daniel D. Reidpath

    2012-06-01

    Full Text Available Introduction: Population monitoring and screening of blood pressure is an important part of any population health strategy. Qualified health workers are expensive and often unavailable for screening. Non-health workers with electronic blood pressure monitors are increasingly used in community-based research. This approach is unvalidated. In a poor, urban community we compared blood pressure measurements taken by non-health workers using electronic devices against qualified health workers using mercury sphygmomanometers. Method: Fifty-six adult volunteers participated in the research. Data were collected by five qualified health workers, and six non-health workers. Participants were randomly allocated to have their blood pressure measured on four consecutive occasions by alternating a qualified health worker with a non-health worker. Descriptive statistics and graphs, and mixed effects linear models to account for the repeated measurement were used in the analysis. Results: Blood pressure readings by non-health workers were more reliable than those taken by qualified health workers. There was no significant difference between the readings taken by qualified health workers and those taken by non-health workers for systolic blood pressure. Non-health workers were, on average, 5–7 mmHg lower in their measures of blood pressure than the qualified health workers (95%HPD: −2.9 to −10.0 for diastolic blood pressure. Conclusion: The results provide empirical evidence that supports the practice of non-health workers using electronic devices for BP measurement in community-based research and screening. Non-health workers recorded blood pressures that differed from qualified health workers by no more than 10 mmHg. The approach is promising, but more research is needed to establish the generalisability of the results.

  10. High Temperature Dynamic Pressure Measurements Using Silicon Carbide Pressure Sensors

    Science.gov (United States)

    Okojie, Robert S.; Meredith, Roger D.; Chang, Clarence T.; Savrun, Ender

    2014-01-01

    Un-cooled, MEMS-based silicon carbide (SiC) static pressure sensors were used for the first time to measure pressure perturbations at temperatures as high as 600 C during laboratory characterization, and subsequently evaluated in a combustor rig operated under various engine conditions to extract the frequencies that are associated with thermoacoustic instabilities. One SiC sensor was placed directly in the flow stream of the combustor rig while a benchmark commercial water-cooled piezoceramic dynamic pressure transducer was co-located axially but kept some distance away from the hot flow stream. In the combustor rig test, the SiC sensor detected thermoacoustic instabilities across a range of engine operating conditions, amplitude magnitude as low as 0.5 psi at 585 C, in good agreement with the benchmark piezoceramic sensor. The SiC sensor experienced low signal to noise ratio at higher temperature, primarily due to the fact that it was a static sensor with low sensitivity.

  11. New method for remote and repeatable monitoring of intraocular pressure variations.

    Science.gov (United States)

    Margalit, Israel; Beiderman, Yevgeny; Skaat, Alon; Rosenfeld, Elkanah; Belkin, Michael; Tornow, Ralf-Peter; Mico, Vicente; Garcia, Javier; Zalevsky, Zeev

    2014-02-01

    We present initial steps toward a new measurement device enabling high-precision, noncontact remote and repeatable monitoring of intraocular pressure (IOP)-based on an innovative measurement principle. Using only a camera and a laser source, the device measures IOP by tracking the secondary speckle pattern trajectories produced by the reflection of an illuminating laser beam from the iris or the sclera. The device was tested on rabbit eyes using two different methods to modify IOP: via an infusion bag and via mechanical pressure. In both cases, the eyes were stimulated with increasing and decreasing ramps of the IOP. As IOP variations changed the speckle distributions reflected back from the eye, data were recorded under various optical configurations to define and optimize the best experimental configuration for the IOP extraction. The association between the data provided by our proposed device and that resulting from controlled modification of the IOP was assessed, revealing high correlation (R2=0.98) and sensitivity and providing a high-precision measurement (5% estimated error) for the best experimental configuration. Future steps will be directed toward applying the proposed measurement principle in clinical trials for monitoring IOP with human subjects.

  12. Thermal separation of soil particles from thermal conductivity measurement under various air pressures.

    Science.gov (United States)

    Lu, Sen; Ren, Tusheng; Lu, Yili; Meng, Ping; Zhang, Jinsong

    2017-01-05

    The thermal conductivity of dry soils is related closely to air pressure and the contact areas between solid particles. In this study, the thermal conductivity of two-phase soil systems was determined under reduced and increased air pressures. The thermal separation of soil particles, i.e., the characteristic dimension of the pore space (d), was then estimated based on the relationship between soil thermal conductivity and air pressure. Results showed that under both reduced and increased air pressures, d estimations were significantly larger than the geometrical mean separation of solid particles (D), which suggested that conductive heat transfer through solid particles dominated heat transfer in dry soils. The increased air pressure approach gave d values lower than that of the reduced air pressure method. With increasing air pressure, more collisions between gas molecules and solid surface occurred in micro-pores and intra-aggregate pores due to the reduction of mean free path of air molecules. Compared to the reduced air pressure approach, the increased air pressure approach expressed more micro-pore structure attributes in heat transfer. We concluded that measuring thermal conductivity under increased air pressure procedures gave better-quality d values, and improved soil micro-pore structure estimation.

  13. How important is the recommended slow cuff pressure deflation rate for blood pressure measurement?

    Science.gov (United States)

    Zheng, Dingchang; Amoore, John N; Mieke, Stephan; Murray, Alan

    2011-10-01

    Cuff pressure deflation rate influences blood pressure (BP) measurement. However, there is little quantitative clinical evidence on its effect. Oscillometric pulses recorded from 75 subjects at the recommended deflation rate of 2-3 mmHg per second were analyzed. Some pulses were removed to realize six faster rates (2-7 times faster than the original). Systolic, diastolic, and mean arterial blood pressures (SBP, DBP, MAP) were determined from the original and six reconstructed oscillometric waveforms. Manual measurement was based on the appearance of oscillometric pulse peaks, and automatic measurement on two model envelopes (linear and polynomial) fitted to the sequence of oscillometric pulse amplitudes. The effects of deflation rate on BP determination and within-subject BP variability were analyzed. For SBP and DBP determined from the manual measurement, different deflation rates resulted in significant changes (both p deflation rate effect (all p > 0.3). Faster deflation increased the within-subject BP variability (all p deflation rate, and for the automatic model-based techniques, the deflation rate had little effect.

  14. Diagnostic accuracy of manual office blood pressure measurement in ambulatory hypertensive patients in Korea.

    Science.gov (United States)

    Kim, Sehun; Park, Jin Joo; Lee, Seung-Ah; Cho, Youngjin; Yoon, Yeonyee E; Oh, Il-Young; Yoon, Chang-Hwan; Suh, Jung-Won; Cho, Young-Seok; Youn, Tae-Jin; Cho, Goo-Yeong; Chae, In-Ho; Lee, Hae-Young; Shin, Jinho; Park, Sungha; Choi, Dong-Ju

    2018-01-01

    Currently, office blood pressure (OBP) is the most widely used method of measuring blood pressure (BP) in daily clinical practice. However, data on the diagnostic accuracy of OBP in reference to ambulatory blood pressure (ABP) are scarce in Korea. In retrospective and prospective cohorts, manual OBP and ABP measurements were compared among ambulatory hypertensive patients. Hypertension was defined as systolic OBP ≥ 140 mmHg and/or diastolic OBP ≥ 90 mmHg, and systolic ABP ≥ 130 mmHg and/or diastolic ABP ≥ 80 mmHg. In the retrospective cohort (n = 903), the mean OBP1 (before ABP measurement) was higher than ABP in both systolic (138 ± 17 mmHg vs. 123 ± 13 mmHg, p ABP ( r 2 = 0.038, p ABP, which is the reference method for measuring BP, was 43.9%. The prospective cohort (n = 57) showed similar results. In a subgroup analysis, male patients had higher false negative results (masked or under-treated hypertension) than did female patients (26.1% vs. 17.8%, p = 0.003), whereas female patients had a higher false positive rate (white-coat or over-treated hypertension) than did male patients (28.7% vs. 15.2%, p ABP. Men and women have different patterns of discordance. These findings indicate that management of hypertensive patients with manual OBP measurements may be suboptimal and encourages the use of ABP in ambulatory hypertensive patients.

  15. Experimental viscosity measurements of biodiesels at high pressure

    Directory of Open Access Journals (Sweden)

    Schaschke C.J.

    2016-01-01

    Full Text Available The viscosity of biodiesels of soybean and rapeseed biodiesels blended with mineral diesel fuel were measured at pressures of up to 200 MPa. Using a falling sinker-type viscometer reproducible viscosity data were obtained based on the time taken for a sinker to descend a fixed distance down an enclosed tube under the influence of gravity. Measurements were taken using pressures which correspond to those of interest in automotive common rail diesel engines, and at temperatures of between 25ºC and 80ºC. In all cases, the viscosity of the biodiesel blends were found to increase exponentially for which the blends were noted as being more viscous than pure mineral fuels. A pressure-freezing effect was not observed for the blends.

  16. [Parkinson gait analysis using in-shoe plantar pressure measurements].

    Science.gov (United States)

    Pihet, D; Moretto, P; Defebvre, L; Thevenon, A

    2006-02-01

    The literature reports some studies describing the walking pattern of patients with Parkinson's disease, its deterioration with disease severity and the effects of various treatments. Other studies concerned the plantar pressure distribution when walking. The aim of this study was to validate the use of baropodometric measurements for gait analysis of parkinsonian patients at various stages of disease severity and in on and off phases. Fifteen normal control subjects and fifteen parkinsonian patients equipped with a plantar pressure measurement system performed walking tests. The parkinsonian patients performed the walking tests in off phase then in on phase. A clinical examination was performed to score the motor handicap on the UPDRS scale. Analysis of the plantar pressures of the parkinsonian subjects under various footprint areas detected significant baropodometric differences compared with controls, between groups with different UPDRS scores, and before and after L-Dopa treatment. Plantar pressures measurements allow a sufficiently fine discrimination for using it to detect parkinsonism and monitor patients with Parkinson's disease.

  17. Prediction of the relationship between flow of tubular pump and differential pressure within inlet passage with CFD method

    International Nuclear Information System (INIS)

    Yu, Y H; Cheng, B

    2012-01-01

    The measurement of flow of tubular pump, in which the differential pressure of two measuring points within inlet passage is replaced by the mean differential pressure of two specified section of inlet passage to calibrate the relationship between flow and differential pressure, is developed. The numerical simulation on differential pressure of two measuring points within inlet passage, which is started before the pump set test, is carried out with the standard k-ε turbulence model and SIMPLEC algorithm. The comparison of the relationships between flow and differential pressure fitted respectively with the data from numerical simulation and pump set test shows that the calibration accuracy about two different sources of data is nearly same. The conclusion can be drawn that the calibration of the relationship between flow and differential pressure with CFD is feasible. The CFD-based flow measurement method, as a more simple and convenient way, can be applied in tubular pumps.

  18. Sound field separation with sound pressure and particle velocity measurements

    DEFF Research Database (Denmark)

    Fernandez Grande, Efren; Jacobsen, Finn; Leclère, Quentin

    2012-01-01

    separation techniques make it possible to distinguish between outgoing and incoming waves from the two sides, and thus NAH can be applied. In this paper, a separation method based on the measurement of the particle velocity in two layers and another method based on the measurement of the pressure...... and the velocity in a single layer are proposed. The two methods use an equivalent source formulation with separate transfer matrices for the outgoing and incoming waves, so that the sound from the two sides of the array can be modeled independently. A weighting scheme is proposed to account for the distance......In conventional near-field acoustic holography (NAH) it is not possible to distinguish between sound from the two sides of the array, thus, it is a requirement that all the sources are confined to only one side and radiate into a free field. When this requirement cannot be fulfilled, sound field...

  19. Dynamic tire pressure sensor for measuring ground vibration.

    Science.gov (United States)

    Wang, Qi; McDaniel, James Gregory; Wang, Ming L

    2012-11-07

    This work presents a convenient and non-contact acoustic sensing approach for measuring ground vibration. This approach, which uses an instantaneous dynamic tire pressure sensor (DTPS), possesses the capability to replace the accelerometer or directional microphone currently being used for inspecting pavement conditions. By measuring dynamic pressure changes inside the tire, ground vibration can be amplified and isolated from environmental noise. In this work, verifications of the DTPS concept of sensing inside the tire have been carried out. In addition, comparisons between a DTPS, ground-mounted accelerometer, and directional microphone are made. A data analysis algorithm has been developed and optimized to reconstruct ground acceleration from DTPS data. Numerical and experimental studies of this DTPS reveal a strong potential for measuring ground vibration caused by a moving vehicle. A calibration of transfer function between dynamic tire pressure change and ground acceleration may be needed for different tire system or for more accurate application.

  20. Vapour pressures and heat capacity measurements on the C7-C9 secondary aliphatic alcohols

    International Nuclear Information System (INIS)

    Verevkin, Sergey P.; Schick, Christoph

    2007-01-01

    Molar enthalpies of vaporization of secondary C 7 -C 9 alkanols were obtained from the temperature dependence of the vapour pressure measured by the transpiration method. The measured data sets were checked for internal consistency successfully. A large number of the primary experimental results on temperature dependences of vapour pressures of secondary alcohols have been collected from the literature and have been treated uniform in order to derive their vaporization enthalpies at the reference temperature 298.15 K. This collection, together with our experimental results, have helped to ascertain the database for branched aliphatic alcohols

  1. Spectrally resolved pressure dependence measurements of air fluorescence emission with AIRFLY

    International Nuclear Information System (INIS)

    Ave, M.; Bohacova, M.; Buonomo, B.; Busca, N.; Cazon, L.; Chemerisov, S.D.; Conde, M.E.; Crowell, R.A.; Di Carlo, P.; Di Giulio, C.; Doubrava, M.; Esposito, A.; Facal, P.; Franchini, F.J.; Hoerandel, J.; Hrabovsky, M.; Iarlori, M.; Kasprzyk, T.E.; Keilhauer, B.; Klages, H.

    2008-01-01

    The knowledge of the fluorescence emission as a function of atmospheric parameters is essential for the detection of extensive air showers with the fluorescence technique. In this paper, we summarize AIRFLY published measurements of the pressure dependence of the fluorescence yield. The spectral distribution of the fluorescent light between 280 and 429 nm has been measured with high resolution. Relative intensities of 34 spectral lines have been determined. The pressure dependence of 25 lines was measured in terms of quenching reference pressures p λ ' in air. This set of AIRFLY measurements yields the most comprehensive parametrization of the pressure dependence of the fluorescent spectrum.

  2. Continuous Blood Pressure Monitoring in Daily Life

    Science.gov (United States)

    Lopez, Guillaume; Shuzo, Masaki; Ushida, Hiroyuki; Hidaka, Keita; Yanagimoto, Shintaro; Imai, Yasushi; Kosaka, Akio; Delaunay, Jean-Jacques; Yamada, Ichiro

    Continuous monitoring of blood pressure in daily life could improve early detection of cardiovascular disorders, as well as promoting healthcare. Conventional ambulatory blood pressure monitoring (ABPM) equipment can measure blood pressure at regular intervals for 24 hours, but is limited by long measuring time, low sampling rate, and constrained measuring posture. In this paper, we demonstrate a new method for continuous real-time measurement of blood pressure during daily activities. Our method is based on blood pressure estimation from pulse wave velocity (PWV) calculation, which formula we improved to take into account changes in the inner diameter of blood vessels. Blood pressure estimation results using our new method showed a greater precision of measured data during exercise, and a better accuracy than the conventional PWV method.

  3. Innovations in plantar pressure and foot temperature measurements in diabetes

    NARCIS (Netherlands)

    Bus, S. A.

    2016-01-01

    Plantar pressure and temperature measurements in the diabetic foot primarily contribute to identifying abnormal values that increase risk for foot ulceration, and they are becoming increasingly more integrated in clinical practice and daily life of the patient. While plantar pressure measurements

  4. Pressure algorithm for elliptic flow calculations with the PDF method

    Science.gov (United States)

    Anand, M. S.; Pope, S. B.; Mongia, H. C.

    1991-01-01

    An algorithm to determine the mean pressure field for elliptic flow calculations with the probability density function (PDF) method is developed and applied. The PDF method is a most promising approach for the computation of turbulent reacting flows. Previous computations of elliptic flows with the method were in conjunction with conventional finite volume based calculations that provided the mean pressure field. The algorithm developed and described here permits the mean pressure field to be determined within the PDF calculations. The PDF method incorporating the pressure algorithm is applied to the flow past a backward-facing step. The results are in good agreement with data for the reattachment length, mean velocities, and turbulence quantities including triple correlations.

  5. Intracochlear pressure measurements in scala media inform models of cochlear mechanics

    Science.gov (United States)

    Kale, Sushrut; Olson, Elizabeth S.

    2015-12-01

    In the classic view of cochlear mechanics, the cochlea is comprised of two identical fluid chambers separated by the cochlear partition (CP). In this view the traveling wave pressures in the two chambers mirror each other; they are equal in magnitude and opposite in phase. A fast pressure mode adds approximately uniformly. More recent models of cochlear mechanics take into account the structural complexity of the CP and the resulting additional mechanical modes would lead to distinct (non-symmetric) patterns of pressure and motion on the two sides of the CP. However, there was little to no physiological data that explored these predictions. To this aim, we measured intracochlear fluid pressure in scala media (SM), including measurements close to the sensory tissue, using miniaturized pressure sensors (˜ 80 μm outer diameter). Measurements were made in-vivo from the basal cochlear turn in gerbils. SM pressure was measured at two longitudinal locations in different preparations. In a subset of the experiments SM and ST (scala tympani) pressures were measured at the same longitudinal location. Traveling wave pressures were observed in both SM and ST, and showed the relative phase predicted by the classical theory. In addition, SM pressure showed spatial variations that had not been observed in ST, which points to a relatively complex CP motion on the SM side. These data both underscore the first-order validity of the classic cochlear traveling wave model, and open a new view to CP mechanics.

  6. Design of a 0-50 mbar pressure measurement channel compatible with the LHC tunnel radiation environment

    Science.gov (United States)

    Casas, Juan; Jelen, Dorota; Trikoupis, Nikolaos

    2017-02-01

    The monitoring of cryogenic facilities often require the measurement of pressure in the sub 5’000 Pa range that are used for flow metering applications, for saturated superfluid helium, etc. The pressure measurement is based on the minute displacement of a sensing diaphragm often through contactless techniques by using capacitive or inductive methods. The LHC radiation environment forbid the use of standard commercial sensors because of the embedded electronics that are affected both by radiation induced drift and transient Single Event Effects (SEE). Passive pressure sensors from two manufacturers were investigated and a CERN designed radiation-tolerant electronics has been developed for measuring variable-reluctance sensors. During the last maintenance stop of the LHC accelerator, four absolute pressure sensors were installed in some of the low pressure bayonet heat exchangers and four differential pressure sensors on the venturi flowmeters that monitor the cooling flow of the 20.5 kA current leads of the ATLAS end-cap superconducting toroids. The pressure sensors operating range is about 1000 to 5000 Pa and the targeted uncertainty is +/- 50 Pa which would permit to measure the equivalent saturation temperature at 1.8 K within better than 0.01 K. This paper describes the radiation hard measuring head that is based on an inductive bridge, its associated radiation-tolerant electronics that is installed under the LHC superconducting magnets or the ATLAS detector cavern; and the first operational experience.

  7. A note on measurement of sound pressure with intensity probes

    DEFF Research Database (Denmark)

    Juhl, Peter; Jacobsen, Finn

    2004-01-01

    be improved under a variety of realistic sound field conditions by applying a different weighting of the two pressure signals from the probe. The improved intensity probe can measure the sound pressure more accurately at high frequencies than an ordinary sound intensity probe or an ordinary sound level meter......The effect of scattering and diffraction on measurement of sound pressure with "two-microphone" sound intensity probes is examined using an axisymmetric boundary element model of the probe. Whereas it has been shown a few years ago that the sound intensity estimated with a two-microphone probe...... is reliable up to 10 kHz when using 0.5 in. microphones in the usual face-to-face arrangement separated by a 12 mm spacer, the sound pressure measured with the same instrument will typically be underestimated at high frequencies. It is shown in this paper that the estimate of the sound pressure can...

  8. Equipment for liquid metal pressure measurement

    International Nuclear Information System (INIS)

    Jung, J.

    1977-01-01

    Equipment is proposed for measuring liquid metal pressure in piping or a tank. An auxiliary piping is connected to the piping or tank at the measuring point. The auxiliary piping transports liquid metal to a container by means of an electromagnetic pump. The piping also houses an electromagnetic flow ratemeter connected to an electric comparator. The comparator and the electromagnetic pump are connected to the pump output generator. (Z.M.)

  9. A Fast Multimodal Ectopic Beat Detection Method Applied for Blood Pressure Estimation Based on Pulse Wave Velocity Measurements in Wearable Sensors.

    Science.gov (United States)

    Pflugradt, Maik; Geissdoerfer, Kai; Goernig, Matthias; Orglmeister, Reinhold

    2017-01-14

    Automatic detection of ectopic beats has become a thoroughly researched topic, with literature providing manifold proposals typically incorporating morphological analysis of the electrocardiogram (ECG). Although being well understood, its utilization is often neglected, especially in practical monitoring situations like online evaluation of signals acquired in wearable sensors. Continuous blood pressure estimation based on pulse wave velocity considerations is a prominent example, which depends on careful fiducial point extraction and is therefore seriously affected during periods of increased occurring extrasystoles. In the scope of this work, a novel ectopic beat discriminator with low computational complexity has been developed, which takes advantage of multimodal features derived from ECG and pulse wave relating measurements, thereby providing additional information on the underlying cardiac activity. Moreover, the blood pressure estimations' vulnerability towards ectopic beats is closely examined on records drawn from the Physionet database as well as signals recorded in a small field study conducted in a geriatric facility for the elderly. It turns out that a reliable extrasystole identification is essential to unsupervised blood pressure estimation, having a significant impact on the overall accuracy. The proposed method further convinces by its applicability to battery driven hardware systems with limited processing power and is a favorable choice when access to multimodal signal features is given anyway.

  10. Electrochemical noise measurements under pressurized water reactor conditions

    International Nuclear Information System (INIS)

    Van Nieuwenhove, R.

    2000-01-01

    Electrochemical potential noise measurements on sensitized stainless steel pressure tubes under pressurized water reactor (PWR) conditions were performed for the first time. Very short potential spikes, believed to be associated to crack initiation events, were detected when stressing the sample above the yield strength and increased in magnitude until the sample broke. Sudden increases of plastic deformation, as induced by an increased tube pressure, resulted in slower, high-amplitude potential transients, often accompanied by a reduction in noise level

  11. Discarding the first of three nurse-auscultatory or oscillometric blood pressure measurements does not improve the association of office blood pressure with ABPM.

    Science.gov (United States)

    Graves, John W; Grossardt, Brandon R

    2010-06-01

    Guidelines for office blood pressure (BP) measurements recommend two or more readings at each visit. It has been suggested that discarding the first reading may improve the diagnostic utility of office readings. We compare two methods of office BP measurement to determine whether discarding the first BP affects their association with ambulatory blood pressure monitoring (ABPM) readings. We studied measurements in 313 mildly hypertensive patients (181 men, median age 51 years) at the end of the washout phase of a hypertension treatment trial. All patients had three auscultatory readings by a trained nurse using a mercury manometer before a 24-h ABPM and three automated readings (Omron 705 CP) to American Heart Association standards after ABPM. Daytime ABPM (09:00-21:00) of systolic BP and diastolic BP were compared with office methods using first only, second and third only, and all three readings. Associations were assessed using Bland-Altman plots and Pearson's correlations. Bland-Altman plots revealed no differences between office methods and daytime ABPM regardless of whether the first reading was included or discarded. Results were similar for both systolic BP and diastolic BP. The Pearson correlations of office method readings with ABPM readings were lowest using the first measurement alone; however, discarding the first measurement did not improve the correlation compared with using all three readings. Discarding the first office BP reading does not change the association of office BP with ABPM or improve the correlation with ABPM values in hypertensive patients.

  12. Simultaneous compared with sequential blood pressure measurement results in smaller inter-arm blood pressure differences.

    Science.gov (United States)

    van der Hoeven, Niels V; Lodestijn, Sophie; Nanninga, Stephanie; van Montfrans, Gert A; van den Born, Bert-Jan H

    2013-11-01

    There are currently few recommendations on how to assess inter-arm blood pressure (BP) differences. The authors compared simultaneous with sequential measurement on mean BP, inter-arm BP differences, and within-visit reproducibility in 240 patients stratified according to age (simultaneous and three sequential BP measurements were taken in each patient. Starting measurement type and starting arm for sequential measurements were randomized. Mean BP and inter-arm BP differences of the first pair and reproducibility of inter-arm BP differences of the first and second pair were compared between both methods. Mean systolic BP was 1.3±7.5 mm Hg lower during sequential compared with simultaneous measurement (Psequential measurement was on average higher than the second, suggesting an order effect. Absolute systolic inter-arm BP differences were smaller on simultaneous (6.2±6.7/3.3±3.5 mm Hg) compared with sequential BP measurement (7.8±7.3/4.6±5.6 mm Hg, PSimultaneous measurement of BP at both arms reduces order effects and results in smaller inter-arm BP differences, thereby potentially reducing unnecessary referral and diagnostic procedures. ©2013 Wiley Periodicals, Inc.

  13. A comparison between the dimensions of positive transtibial residual limb molds prepared by air pressure casting and weight-bearing casting methods.

    Science.gov (United States)

    Hajiaghaei, Behnam; Ebrahimi, Ismail; Kamyab, Mojtaba; Saeedi, Hassan; Jalali, Maryam

    2016-01-01

    Creating a socket with proper fit is an important factor to ensure the comfort and control of prosthetic devices. Several techniques are commonly used to cast transtibial stumps but their effect on stump shape deformation is not well understood. This study compares the dimensions, circumferences and volumes of the positive casts and also the socket comfort between two casting methods. Our hypothesis was that the casts prepared by air pressure method have less volume and are more comfortable than those prepared by weight bearing method. Fifteen transtibial unilateral amputees participated in the study. Two weight bearing and air pressure casting methods were utilized for their residual limbs. The diameters and circumferences of various areas of the residual limbs and positive casts were compared. The volumes of two types of casts were measured by a volumeter and compared. Visual Analogue Scale (VAS) was used to measure the sockets fit comfort. Circumferences at 10 and 15 cm below the patella on the casts were significantly smaller in air pressure casting method compared to the weight bearing method (p=0.00 and 0.01 respectively). The volume of the cast in air pressure method was lower than that of the weight bearing method (p=0.006). The amputees found the fit of the sockets prepared by air pressure method more comfortable than the weight bearing sockets (p=0.015). The air pressure casting reduced the circumferences of the distal portion of residual limbs which has more soft tissue and because of its snug fit it provided more comfort for amputees, according to the VAS measurements.

  14. Differential pressure distribution measurement for the development of insect-sized wings

    International Nuclear Information System (INIS)

    Takahashi, Hidetoshi; Matsumoto, Kiyoshi; Shimoyama, Isao

    2013-01-01

    This paper reports on the measurement of the differential pressure distribution over a flat, thin wing using a micro-electro-mechanical systems sensor. Sensors featuring a piezoresistive cantilever were attached to a polyimide/Cu wing. Because the weight of the cantilever element was less than 10 ng, the sensor can measure the differential pressure without interference from inertial forces, such as wing flapping motions. The dimensions of the sensor chips and the wing were 1.0 mm × 1.0 mm × 0.3 mm and 100 mm × 30 mm × 1 mm, respectively. The differential pressure distribution along the wing's chord direction was measured in a wind tunnel at an air velocity of 4.0 m s –1 by changing the angle of attack. It was confirmed that the pressure coefficient calculated by the measured differential pressure distribution was similar to the value measured by a load cell. (paper)

  15. Comparison of invasive and oscillometric blood pressure measurement techniques in anesthetized camelids.

    Science.gov (United States)

    Aarnes, Turi K; Hubbell, John A E; Lerche, Phillip; Bednarski, Richard M

    2012-08-01

    This study assessed the accuracy of the oscillometric method for arterial blood pressure (ABP) monitoring in anesthetized camelids. Twenty camelids were anesthetized and systolic ABP (SABP), mean ABP (MABP), and diastolic ABP (DABP) were measured directly and using the oscillometric method. The mean difference between SABP measurements was -9.9 ± 21.9 mmHg with a range of -76 to 54 mmHg, and the 95% limits of agreement (LOA) were -33 to 53 mmHg. The difference between DABP measurements was -1.8 ± 15.6 mmHg with a range of -81 to 36 mmHg, and the 95% LOA were -32 to 29 mmHg. The difference between MABP measurements was -2.9 ± 17.0 mmHg with a range of -81 to 36 mmHg, and the 95% LOA were -30 to 36 mmHg. Accurate ABP monitoring in anesthetized camelids cannot be accomplished using the oscillometric method.

  16. Importance of Calibration Method in Central Blood Pressure for Cardiac Structural Abnormalities.

    Science.gov (United States)

    Negishi, Kazuaki; Yang, Hong; Wang, Ying; Nolan, Mark T; Negishi, Tomoko; Pathan, Faraz; Marwick, Thomas H; Sharman, James E

    2016-09-01

    Central blood pressure (CBP) independently predicts cardiovascular risk, but calibration methods may affect accuracy of central systolic blood pressure (CSBP). Standard central systolic blood pressure (Stan-CSBP) from peripheral waveforms is usually derived with calibration using brachial SBP and diastolic BP (DBP). However, calibration using oscillometric mean arterial pressure (MAP) and DBP (MAP-CSBP) is purported to provide more accurate representation of true invasive CSBP. This study sought to determine which derived CSBP could more accurately discriminate cardiac structural abnormalities. A total of 349 community-based patients with risk factors (71±5years, 161 males) had CSBP measured by brachial oscillometry (Mobil-O-Graph, IEM GmbH, Stolberg, Germany) using 2 calibration methods: MAP-CSBP and Stan-CSBP. Left ventricular hypertrophy (LVH) and left atrial dilatation (LAD) were measured based on standard guidelines. MAP-CSBP was higher than Stan-CSBP (149±20 vs. 128±15mm Hg, P curve analyses, MAP-CSBP significantly better discriminated LVH compared with Stan-CSBP (area under the curve (AUC) 0.66 vs. 0.59, P = 0.0063) and brachial SBP (0.62, P = 0.027). Continuous net reclassification improvement (NRI) (P AUC 0.63 vs. 0.56, P = 0.005) and conventional brachial SBP (0.58, P = 0.006), whereas Stan-CSBP provided no better discrimination than conventional brachial BP (P = 0.09). CSBP is calibration dependent and when oscillometric MAP and DBP are used, the derived CSBP is a better discriminator for cardiac structural abnormalities. © American Journal of Hypertension, Ltd 2016. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. SOIL-AIR PERMEABILITY MEASUREMENT WITH A TRANSIENT PRESSURE BUILDUP METHOD

    Science.gov (United States)

    An analytical solution for transient pressure change in a single venting well was derived from mass conservation of air, Darcy's law of flow in porous media, and the ideal gas law equation of state. Slopes of plots of Pw2 against ln (t+Δt)/Δt similar to Homer's plot were used to ...

  18. Measurement of rock properties at elevated pressures and temperatures

    International Nuclear Information System (INIS)

    Pincus, H.J.; Hoskins, E.R.

    1985-01-01

    The papers in this volume were presented at an ASTM symposium held on 20 June 1983 in conjunction with the 24th Annual Rock Mechanics Symposium at Texas A and M University, College Station, TX. The purpose of these papers is to present recent developments in the measurement of rock properties at elevated pressures and temperatures, and to examine and interpret the data produced by such measurement. The need for measuring rock properties at elevated pressures and temperatures has become increasingly important in recent years. Location and design of nuclear waste repositories, development of geothermal energy sites, and design and construction of deep excavations for civil, military, and mining engineering require significantly improved capabilities for measuring rock properties under conditions substantially different from those prevailing in most laboratory and in situ work. The development of high-pressure, high-temperature capabilities is also significant for the analysis of tectonic processes

  19. An FBG Optical Approach to Thermal Expansion Measurements under Hydrostatic Pressure.

    Science.gov (United States)

    Rosa, Priscila F S; Thomas, Sean M; Balakirev, Fedor F; Betts, Jon; Seo, Soonbeom; Bauer, Eric D; Thompson, Joe D; Jaime, Marcelo

    2017-11-04

    We report on an optical technique for measuring thermal expansion and magnetostriction at cryogenic temperatures and under applied hydrostatic pressures of 2.0 GPa. Optical fiber Bragg gratings inside a clamp-type pressure chamber are used to measure the strain in a millimeter-sized sample of CeRhIn₅. We describe the simultaneous measurement of two Bragg gratings in a single optical fiber using an optical sensing instrument capable of resolving changes in length [dL/L = (L- L₀)/L₀] on the order of 10 -7 . Our results demonstrate the possibility of performing high-resolution thermal expansion measurements under hydrostatic pressure, a capability previously hindered by the small working volumes typical of pressure cells.

  20. Validation of the activity expansion method with ultrahigh pressure shock equations of state

    Science.gov (United States)

    Rogers, Forrest J.; Young, David A.

    1997-11-01

    Laser shock experiments have recently been used to measure the equation of state (EOS) of matter in the ultrahigh pressure region between condensed matter and a weakly coupled plasma. Some ultrahigh pressure data from nuclear-generated shocks are also available. Matter at these conditions has proven very difficult to treat theoretically. The many-body activity expansion method (ACTEX) has been used for some time to calculate EOS and opacity data in this region, for use in modeling inertial confinement fusion and stellar interior plasmas. In the present work, we carry out a detailed comparison with the available experimental data in order to validate the method. The agreement is good, showing that ACTEX adequately describes strongly shocked matter.

  1. Measurement of the differential pressure of liquid metals

    International Nuclear Information System (INIS)

    Metz, H.J.

    1975-01-01

    This patent relates to an improved means for measuring the differential pressure between any two points in a process liquid metal coolant loop, wherein the flow of liquid metal in a pipe is opposed by a permanent magnet liquid metal pump until there is almost zero flow shown by a magnetic type flowmeter. The pressure producing the liquid metal flow is inferred from the rate of rotation of the permanent magnet pump. In an alternate embodiment, a differential pressure transducer is coupled to a process pipeline by means of high-temperature bellows or diaphragm seals, and a permanent magnet liquid metal pump in the high-pressure transmission line to the pressure transducer can be utilized either for calibration of the transducer or for determining the process differential pressure as a function of the magnet pump speed

  2. Measurement of the differential pressure of liquid metals

    Science.gov (United States)

    Metz, H.J.

    1975-09-01

    This patent relates to an improved means for measuring the differential pressure between any two points in a process liquid metal coolant loop, wherein the flow of liquid metal in a pipe is opposed by a permanent magnet liquid metal pump until there is almost zero flow shown by a magnetic type flowmeter. The pressure producing the liquid metal flow is inferred from the rate of rotation of the permanent magnet pump. In an alternate embodiment, a differential pressure transducer is coupled to a process pipeline by means of high-temperature bellows or diaphragm seals, and a permanent magnet liquid metal pump in the high-pressure transmission line to the pressure transducer can be utilized either for calibration of the transducer or for determining the process differential pressure as a function of the magnet pump speed. (auth)

  3. Strain measurements during pressurized thermal shock experiment

    International Nuclear Information System (INIS)

    Tarso Vida Gomes, P. de; Julio Ricardo Barreto Cruz; Tanius Rodrigues Mansur; Denis Henrique Bianchi Scaldaferri; Miguel Mattar Neto

    2005-01-01

    For the life extension of nuclear power plants, the residual life of most of their components must be evaluated along all their operating time. Concerning the reactor pressure vessel, the pressurized thermal shock (PTS) is a very important event to be considered. For better understanding the effects of this kind of event, tests are made. The approach described here consisted of building a simplified in-scale physical model of the reactor pressure vessel, submitting it to the actual operating temperature and pressure conditions and provoking a thermal shock by means of cold water flow in its external surface. To conduct such test, the Nuclear Technology Development Center (CDTN) has been conducting several studies related to PTS and has also built a laboratory that has made possible the simulation of the PTS loading conditions. Several cracks were produced in the external surface of the reactor pressure vessel model. Strain gages were fixed by means of electrical discharge welding over the cracks regions in both external and internal surfaces. The temperature was monitored in 10 points across the vessel wall. The internal pressure was manually controlled and monitored using a pressure transducer. Two PTS experiments were conducted and this paper presents the strain measurement procedures applied to the reactor pressure vessel model, during the PTS, using strain gages experimental methodology. (authors)

  4. Automated measurement of office, home and ambulatory blood pressure in atrial fibrillation.

    Science.gov (United States)

    Kollias, Anastasios; Stergiou, George S

    2014-01-01

    1. Hypertension and atrial fibrillation (AF) often coexist and are strong risk factors for stroke. Current guidelines for blood pressure (BP) measurement in AF recommend repeated measurements using the auscultatory method, whereas the accuracy of the automated devices is regarded as questionable. This review presents the current evidence on the feasibility and accuracy of automated BP measurement in the presence of AF and the potential for automated detection of undiagnosed AF during such measurements. 2. Studies evaluating the use of automated BP monitors in AF are limited and have significant heterogeneity in methodology and protocols. Overall, the oscillometric method is feasible for static (office or home) and ambulatory use and appears to be more accurate for systolic than diastolic BP measurement. 3. Given that systolic hypertension is particularly common and important in the elderly, the automated BP measurement method may be acceptable for self-home and ambulatory monitoring, but not for professional office or clinic measurement. 4. An embedded algorithm for the detection of asymptomatic AF during routine automated BP measurement with high diagnostic accuracy has been developed and appears to be a useful screening tool for elderly hypertensives. © 2013 Wiley Publishing Asia Pty Ltd.

  5. Measurement of digital blood pressure after local cooling

    DEFF Research Database (Denmark)

    Nielsen, S L; Lassen, N A

    1977-01-01

    A double-inlet plastic cuff was designed for local cooling and systolic blood pressure measurement on the middle phalanx of the fingers. With a tourniquet on the proximal phalanx of one finger, cooling for 5 min made the digital artery temperature equal the skin temperature. The difference between...... the systolic pressure in a control finger and in the cooled finger give the reopening pressure in the digital arteries. At 30, 25, 20, 15, and 10 degrees C, respectively the percent decrease of the finger pressure was 0.2 (0.2), 1.5 (2.5), 8.5 (3.7), 11.4 (3.4), and 15.3 (3.1) in normal young women...

  6. Comparison of different screening methods for blood pressure disorders in children and adolescents

    Directory of Open Access Journals (Sweden)

    Felipe Alves Mourato

    2015-06-01

    Full Text Available OBJECTIVE: To compare different methods of screening for blood pressure disorders in children and adolescents. METHOD: A database with 17,083 medical records of patients from a pediatric cardiology clinic was used. After analyzing the inclusion and exclusion criteria, 5,650 were selected. These were divided into two age groups: between 5 and 13 years and between 13 and 18 years. The blood pressure measurement was classified as normal, pre-hypertensive, or hypertensive, consistent with recent guidelines and the selected screening methods. Sensitivity, specificity, and accuracy were then calculated according to gender and age range. RESULTS: The formulas proposed by Somu and Ardissino's table showed low sensitivity in identifying pre-hypertension in all age groups, whereas the table proposed by Kaelber showed the best results. The ratio between blood pressure and height showed low specificity in the younger age group, but showed good performance in adolescents. CONCLUSION: Screening tools used for the assessment of blood pressure disorders in children and adolescents may be useful to decrease the current rate of underdiagnosis of this condition. The table proposed by Kaelber showed the best results; however, the ratio between BP and height demonstrated specific advantages, as it does not require tables.

  7. Can pyrene probes be used to measure lateral pressure profiles of lipid membranes? Perspective through atomistic simulations

    DEFF Research Database (Denmark)

    Franova, M. D.; Vattulainen, I.; Ollila, O. H. S.

    2014-01-01

    The lateral pressure profile of lipid bilayers has gained a lot of attention, since changes in the pressure profile have been suggested to shift the membrane protein conformational equilibrium. This relation has been mostly studied with theoretical methods, especially with molecular dynamics....../monomer fluorescence ratio has been assumed to represent the lateral pressure in the location of the pyrene moieties. Here, we consider the validity of this assumption through atomistic molecular dynamics simulations in a DOPC (dioleoylphosphatidylcholine) membrane, which hosts di-pyr-PC probes with different acyl...... simulations, since established methods to measure the lateral pressure profile experimentally have not been available. The only experiments that have attempted to gauge the lateral pressure profile have been done by using di-pyrenyl-phosphatidylcholine (di-pyr-PC) probes. In these experiments, the excimer...

  8. Neutron flux measurements in C-9 capsule pressure tube

    International Nuclear Information System (INIS)

    Barbos, D.; Roth, C. S.; Gugiu, D.; Preda, M.

    2001-01-01

    C-9 capsule is a fuel testing facility in which the testing consists of a daily cycle ranging between the limits 100% power to 50% power. C-9 in-pile section with sample holder an instrumentation are introduced in G-9 and G-10 experimental channels. The experimental fuel channel has a maximum value when the in-pile section (pressure tube) is in G-9 channel and minimum value in G-10 channel. In this paper the main goals are determination or measurements of: - axial thermal neutron flux distribution in C-9 pressure tube both in G-9 and G-10 channel; - ratio of maximum neutron flux value in G-9 and the same value in G-9 channel and the same value in G-10 channel; - neutron flux-spectrum. On the basis of axial neutron flux distribution measurements, the experimental fuel element in sample holder position in set. Both axial neutron flux distribution of thermal neutrons and neutron flux-spectrum were performed using multi- foil activation technique. Activation rates were obtained by absolute measurements of the induced activity using gamma spectroscopy methods. To determine the axial thermal neutron flux distribution in G-9 and G-10, Cu 100% wire was irradiated at the reactor power of 2 MW. Ratio between the two maximum values, in G-9 and G-10 channels, is 2.55. Multi-foil activation method was used for neutron flux spectrum measurements. The neutron spectra and flux were obtained from reaction rate measurements by means of SAND 2 code. To obtain gamma-ray spectra, a HPGe detector connected to a multichannel analyzer was used. The spectrometer is absolute efficiency calibrated. The foils were irradiated at 2 MW reactor power in previously determined maximum flux position resulted from wire measurements. This reaction rates were normalized for 10 MW reactor power. Neutron self shielding corrections for the activation foils were applied. The self-shielding corrections are computed using Monte Carlo simulation methods. The measured integral flux is 1.1·10 14 n/cm 2 s

  9. Automatic algorithm for monitoring systolic pressure variation and difference in pulse pressure.

    Science.gov (United States)

    Pestel, Gunther; Fukui, Kimiko; Hartwich, Volker; Schumacher, Peter M; Vogt, Andreas; Hiltebrand, Luzius B; Kurz, Andrea; Fujita, Yoshihisa; Inderbitzin, Daniel; Leibundgut, Daniel

    2009-06-01

    Difference in pulse pressure (dPP) reliably predicts fluid responsiveness in patients. We have developed a respiratory variation (RV) monitoring device (RV monitor), which continuously records both airway pressure and arterial blood pressure (ABP). We compared the RV monitor measurements with manual dPP measurements. ABP and airway pressure (PAW) from 24 patients were recorded. Data were fed to the RV monitor to calculate dPP and systolic pressure variation in two different ways: (a) considering both ABP and PAW (RV algorithm) and (b) ABP only (RV(slim) algorithm). Additionally, ABP and PAW were recorded intraoperatively in 10-min intervals for later calculation of dPP by manual assessment. Interobserver variability was determined. Manual dPP assessments were used for comparison with automated measurements. To estimate the importance of the PAW signal, RV(slim) measurements were compared with RV measurements. For the 24 patients, 174 measurements (6-10 per patient) were recorded. Six observers assessed dPP manually in the first 8 patients (10-min interval, 53 measurements); no interobserver variability occurred using a computer-assisted method. Bland-Altman analysis showed acceptable bias and limits of agreement of the 2 automated methods compared with the manual method (RV: -0.33% +/- 8.72% and RV(slim): -1.74% +/- 7.97%). The difference between RV measurements and RV(slim) measurements is small (bias -1.05%, limits of agreement 5.67%). Measurements of the automated device are comparable with measurements obtained by human observers, who use a computer-assisted method. The importance of the PAW signal is questionable.

  10. Does the Position or Contact Pressure of the Stethoscope Make Any Difference to Clinical Blood Pressure Measurements

    Science.gov (United States)

    Pan, Fan; Zheng, Dingchang; He, Peiyu; Murray, Alan

    2014-01-01

    Abstract This study aimed to investigate the effect of stethoscope position and contact pressure on auscultatory blood pressure (BP) measurement. Thirty healthy subjects were studied. Two identical stethoscopes (one under the cuff, the other outside the cuff) were used to simultaneously and digitally record 2 channels of Korotkoff sounds during linear cuff pressure deflation. For each subject, 3 measurements with different contact pressures (0, 50, and 100 mm Hg) on the stethoscope outside the cuff were each recorded at 3 repeat sessions. The Korotkoff sounds were replayed twice on separate days to each of 2 experienced listeners to determine systolic and diastolic BPs (SBP and DBP). Variance analysis was performed to study the measurement repeatability and the effect of stethoscope position and contact pressure on BPs. There was no significant BP difference between the 3 repeat sessions, between the 2 determinations from each listener, between the 2 listeners and between the 3 stethoscope contact pressures (all P > 0.06). There was no significant SBP difference between the 2 stethoscope positions at the 2 lower stethoscope pressures (P = 0.23 and 0.45), but there was a small (0.4 mm Hg, clinically unimportant) significant difference (P = 0.005) at the highest stethoscope pressure. The key result was that, DBP from the stethoscope under the cuff was significantly lower than that from outside the cuff by 2.8 mm Hg (P stethoscope outside the cuff, tends to give a higher DBP than the true intra-arterial pressure, this study could suggest that the stethoscope position under the cuff, and closer to the arterial occlusion, might yield measurements closer to the actual invasive DBP. PMID:25546675

  11. Automated Office Blood Pressure Measurement.

    Science.gov (United States)

    Myers, Martin G

    2018-04-01

    Manual blood pressure (BP) recorded in routine clinical practice is relatively inaccurate and associated with higher readings compared to BP measured in research studies in accordance with standardized measurement guidelines. The increase in routine office BP is the result of several factors, especially the presence of office staff, which tends to make patients nervous and also allows for conversation to occur. With the disappearance of the mercury sphygmomanometer because of environmental concerns, there is greater use of oscillometric BP recorders, both in the office setting and elsewhere. Although oscillometric devices may reduce some aspects of observer BP measurement error in the clinical setting, they are still associated with higher BP readings, known as white coat hypertension (for diagnosis) or white coat effect (with treated hypertension). Now that fully automated sphygmomanometers are available which are capable of recording several readings with the patient resting quietly, there is no longer any need to have office staff present when BP is being recorded. Such readings are called automated office blood pressure (AOBP) and they are both more accurate than conventional manual office BP and not associated with the white coat phenomena. AOBP readings are also similar to the awake ambulatory BP and home BP, both of which are relatively good predictors of cardiovascular risk. The available evidence suggests that AOBP should now replace manual or electronic office BP readings when screening patients for hypertension and also after antihypertensive drug therapy is initiated. Copyright © 2018. The Korean Society of Cardiology.

  12. Effect of Medial Patellofemoral Ligament Reconstruction Method on Patellofemoral Contact Pressures and Kinematics.

    Science.gov (United States)

    Stephen, Joanna M; Kittl, Christoph; Williams, Andy; Zaffagnini, Stefano; Marcheggiani Muccioli, Giulio Maria; Fink, Christian; Amis, Andrew A

    2016-05-01

    There remains a lack of evidence regarding the optimal method when reconstructing the medial patellofemoral ligament (MPFL) and whether some graft constructs can be more forgiving to surgical errors, such as overtensioning or tunnel malpositioning, than others. The null hypothesis was that there would not be a significant difference between reconstruction methods (eg, graft type and fixation) in the adverse biomechanical effects (eg, patellar maltracking or elevated articular contact pressure) resulting from surgical errors such as tunnel malpositioning or graft overtensioning. Controlled laboratory study. Nine fresh-frozen cadaveric knees were placed on a customized testing rig, where the femur was fixed but the tibia could be moved freely from 0° to 90° of flexion. Individual quadriceps heads and the iliotibial tract were separated and loaded to 205 N of tension using a weighted pulley system. Patellofemoral contact pressures and patellar tracking were measured at 0°, 10°, 20°, 30°, 60°, and 90° of flexion using pressure-sensitive film inserted between the patella and trochlea, in conjunction with an optical tracking system. The MPFL was transected and then reconstructed in a randomized order using a (1) double-strand gracilis tendon, (2) quadriceps tendon, and (3) tensor fasciae latae allograft. Pressure maps and tracking measurements were recorded for each reconstruction method in 2 N and 10 N of tension and with the graft positioned in the anatomic, proximal, and distal femoral tunnel positions. Statistical analysis was undertaken using repeated-measures analyses of variance, Bonferroni post hoc analyses, and paired t tests. Anatomically placed grafts during MPFL reconstruction tensioned to 2 N resulted in the restoration of intact medial joint contact pressures and patellar tracking for all 3 graft types investigated (P > .050). However, femoral tunnels positioned proximal or distal to the anatomic origin resulted in significant increases in the mean

  13. Chemical methods for the use of niobium from pressure vessel cladding as a fast neutron dosimeter

    International Nuclear Information System (INIS)

    Karnani, Hari

    1986-08-01

    the steel samples from the cladding of a pressure vessel of an operating nuclear power reactor were obtained by scraping. The cladding material of the pressure vessel contained about 0.5 % niobium. It was desired to use the niobium as a dosimeter for estimating fast fluences at the pressure vessel. The weak radiation from the reaction product 93m Nb cannot be measured in the presence of other elements and interfering activities. A method was developed to separate niobium from other metals present; the concentration and yield of niobium were determined spectrophotometrically. The irradiated niobium was electrodeposited from aqueous solutions on copper discs. The amount of the deposited niobium was determined by a radiochemical method which makes use of its own radioactivity - measured with a liquid scintillation counter - and the known starting mass of niobium. It was possible to determine the deposited niobium masses (5 to 200 microgram) with a desired degree of accuracy. The absolute emission rate of X-rays could then be measured without any self-absorption or interference from other activities. The mass of niobium on each preparate and its X-ray emission rate, later on, were used as basic experimental data for the estimation of last neutron doses at the pressure vessel

  14. [Mobile Health: IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices].

    Science.gov (United States)

    Zhou, Xia; Wu, Wenli; Bao, Shudi

    2015-07-01

    IEEE Std 1708-2014 breaks through the traditional standards of cuff based blood pressure measuring devices and establishes a normative definition of wearable cuffless blood pressure measuring devices and the objective performance evaluation of this kind of devices. This study firstly introduces the background of the new standard. Then, the standard details will be described, and the impact of cuffless blood pressure measuring devices with the new standard on manufacturers and end users will be addressed.

  15. Method for making a dynamic pressure sensor and a pressure sensor made according to the method

    Science.gov (United States)

    Zuckerwar, Allan J. (Inventor); Robbins, William E. (Inventor); Robins, Glenn M. (Inventor)

    1994-01-01

    A method for providing a perfectly flat top with a sharp edge on a dynamic pressure sensor using a cup-shaped stretched membrane as a sensing element is described. First, metal is deposited on the membrane and surrounding areas. Next, the side wall of the pressure sensor with the deposited metal is machined to a predetermined size. Finally, deposited metal is removed from the top of the membrane in small steps, by machining or lapping while the pressure sensor is mounted in a jig or the wall of a test object, until the true top surface of the membrane appears. A thin indicator layer having a color contrasting with the color of the membrane may be applied to the top of the membrane before metal is deposited to facilitate the determination of when to stop metal removal from the top surface of the membrane.

  16. A novel method for calculating the dynamic capillary force and correcting the pressure error in micro-tube experiment.

    Science.gov (United States)

    Wang, Shuoliang; Liu, Pengcheng; Zhao, Hui; Zhang, Yuan

    2017-11-29

    Micro-tube experiment has been implemented to understand the mechanisms of governing microcosmic fluid percolation and is extensively used in both fields of micro electromechanical engineering and petroleum engineering. The measured pressure difference across the microtube is not equal to the actual pressure difference across the microtube. Taking into account the additional pressure losses between the outlet of the micro tube and the outlet of the entire setup, we propose a new method for predicting the dynamic capillary pressure using the Level-set method. We first demonstrate it is a reliable method for describing microscopic flow by comparing the micro-model flow-test results against the predicted results using the Level-set method. In the proposed approach, Level-set method is applied to predict the pressure distribution along the microtube when the fluids flow along the microtube at a given flow rate; the microtube used in the calculation has the same size as the one used in the experiment. From the simulation results, the pressure difference across a curved interface (i.e., dynamic capillary pressure) can be directly obtained. We also show that dynamic capillary force should be properly evaluated in the micro-tube experiment in order to obtain the actual pressure difference across the microtube.

  17. Standard values of maximum tongue pressure taken using newly developed disposable tongue pressure measurement device.

    Science.gov (United States)

    Utanohara, Yuri; Hayashi, Ryo; Yoshikawa, Mineka; Yoshida, Mitsuyoshi; Tsuga, Kazuhiro; Akagawa, Yasumasa

    2008-09-01

    It is clinically important to evaluate tongue function in terms of rehabilitation of swallowing and eating ability. We have developed a disposable tongue pressure measurement device designed for clinical use. In this study we used this device to determine standard values of maximum tongue pressure in adult Japanese. Eight hundred fifty-three subjects (408 male, 445 female; 20-79 years) were selected for this study. All participants had no history of dysphagia and maintained occlusal contact in the premolar and molar regions with their own teeth. A balloon-type disposable oral probe was used to measure tongue pressure by asking subjects to compress it onto the palate for 7 s with maximum voluntary effort. Values were recorded three times for each subject, and the mean values were defined as maximum tongue pressure. Although maximum tongue pressure was higher for males than for females in the 20-49-year age groups, there was no significant difference between males and females in the 50-79-year age groups. The maximum tongue pressure of the seventies age group was significantly lower than that of the twenties to fifties age groups. It may be concluded that maximum tongue pressures were reduced with primary aging. Males may become weaker with age at a faster rate than females; however, further decreases in strength were in parallel for male and female subjects.

  18. Measurement of Dynamic Urethral Pressures with a High Resolution Manometry System in Continent and Incontinent Women

    Science.gov (United States)

    Kirby, Anna C; Tan-Kim, Jasmine; Nager, Charles W.

    2015-01-01

    Objectives Female stress urinary incontinence (SUI) is caused by urethral dysfunction during dynamic conditions, but current technology has limitations in measuring urethral pressures under dynamic conditions. An 8-French high resolution manometry catheter (HRM) currently in clinical use in gastroenterology may accurately measure urethral pressures under dynamic conditions because it has a 25ms response rate and circumferential pressure sensors along the length of the catheter (ManoScan® ESO, Given Imaging). We evaluated the concordance, repeatability, and tolerability of this catheter. Methods We measured resting, cough, and strain maximum urethral closure pressures (MUCPs) using HRM and measured resting MUCPs with water perfusion side-hole catheter urethral pressure profilometry (UPP) in 37 continent and 28 stress incontinent subjects. Maneuvers were repeated after moving the HRM catheter along the urethral length to evaluate whether results depend on catheter positioning. Visual analog pain scores evaluated the comfort of HRM compared to UPP. Results The correlation coefficient for resting MUCPs measured by HRM vs. UPP was high (r = 0.79, prest, cough, and strain with HRM: r= 0.92, 0.89, and 0.89. Mean MUCPs (rest, cough, strain) were higher in continent than incontinent subjects (all p continent subjects during cough and strain maneuvers compared to rest. Conclusions This preliminary study shows that HRM is concordant with standard technology, repeatable, and well tolerated in the urethra. Incontinent women have more impairment of their urethral closure pressures during cough and strain than continent women. PMID:25185595

  19. High-pressure measuring cell for Raman spectroscopic studies of natural gas

    DEFF Research Database (Denmark)

    Hansen, Susanne Brunsgaard; Berg, Rolf W.; Stenby, Erling Halfdan

    2001-01-01

    A system for obtaining Raman spectra of gases at high pressure has been constructed. In order to ensure that a natural gas sample is totally representative, a high-pressure gas-measuring cell has been developed, built up by stainless steel fittings and a sapphire tube. The design and construction...... of this cell are described. A perfect pressure seal has been demonstrated up to 15.0 MPaA (MPa absolute). The cell has been successfully used to obtain Raman spectra of natural gas samples. Some of these spectra are presented and assigned. The most remarkable observation in the spectra is that it is possible...... to detect hydrogen sulfide at concentrations of 1-3 mg H2S/Nm(3). An attempt to make a quantitative analysis of natural gas by the so-called "ratio method" is presented. In addition to this, the relative normalized differential Raman scattering cross sections for ethane and i-butane molecules at 8.0 MPa...

  20. Leak detection method for long pipeline based on dynamic pressure and wavelet analysis

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Bin; Wang, Likun; Wang, Hongchao; Xiong, Min; Yu, Dongliang; Tan, Dongjie [RnD center of PetroChina Pipeline Company, Langfang, Hebei, (China)

    2010-07-01

    Leaks appear frequently in pipelines, raising the possibility of safety issues. The detection of pipeline leakage is very important for the pipeline industry. This paper investigated a leak detection method on a long pipeline using a dynamic pressure sensor. A new leakage system is proposed based on the measurements obtained from this dynamic pressure sensor. The data were analyzed using the wavelet transformation method. First, the signal provided by the pressure sensor its denoised and then leaks are detected from the presence of singularities in the signal. Field tests were carried out on a product oil pipeline of 94 km length. The in-field test results showed that the minimum ratio of detectable leakage is 0.6 % of throughput and the location error is below 300 m. The response time is less than 120 seconds. This new system has been applied in 5000 km pipelines in China and is proving its efficiency in detecting leak points.

  1. Response characteristics of probe-transducer systems for pressure measurements in gas-solid fluidized beds: how to prevent pitfalls in dynamic pressure measurements

    NARCIS (Netherlands)

    Ommen, van J.R.; Schouten, J.C.; Stappen, van der M.L.M.; Bleek, van den C.M.

    1999-01-01

    It is long known already that the pressure probe–transducer systems applied in gas–solid fluidized beds can distort the measured pressure fluctuations. Several rules of thumb have been proposed to determine probe length and internal diameter required to prevent this. Recently, Xie and Geldart [H.-Y.

  2. Pressure Measurement Sensor

    Science.gov (United States)

    1997-01-01

    FFPI Industries Inc. is the manufacturer of fiber-optic sensors that furnish accurate pressure measurements in internal combustion chambers. Such an assessment can help reduce pollution emitted by these engines. A chief component in the sensor owes its seven year- long development to Lewis Research Center funding to embed optical fibers and sensors in metal parts. NASA support to Texas A&M University played a critical role in developing this fiber optic technology and led to the formation of FFPI Industries and the production of fiber sensor products. The simple, rugged design of the sensor offers the potential for mass production at low cost. Widespread application of the new technology is forseen, from natural gas transmission, oil refining and electrical power generation to rail transport and the petrochemical paper product industry.

  3. Fiber optic pressure sensors in skin-friction measurements

    Science.gov (United States)

    Kidwell, R.

    1985-01-01

    Fiber optic lever pressure sensors intended for use in a low speed wind tunnel environment were designed, constructed and tested for the measurement of normal and shear displacements associated with the pressures acting on a flat aluminum plate. On-site tests performed along with several static and dynamic measurements made have established that, with proper modifications and improvements, the design concepts are acceptable and can be utilized for their intended use. Several elastomers were investigated for use in sensors and for their incorporation into these sensors. Design and assembly techniques for probes and complete sensors were developed.

  4. Hydraulic experiment on evaluation method of tsunami wave pressure using inundation depth and velocity in front of land structure

    International Nuclear Information System (INIS)

    Arimitsu, Tsuyoshi; Ooe, Kazuya; Kawasaki, Koji

    2012-01-01

    Hydraulic experiments were conducted to estimate tsunami wave pressure acting on several different types of land structures and examine the influence of a seawall in front of the structure on tsunami wave pressure. Wave pressures were measured at some points on the structure. The existing hydrostatic formula tended to underestimate tsunami wave pressure under the condition of inundation flow with large Froude number. Estimation method of tsunami wave pressure using inundation depth and horizontal velocity at the front of the structure was proposed based on the experimental results. It was confirmed from comparison with the experiments that the vertical distribution of the maximum tsunami wave pressure can be reproduced by employing the proposed method in this study. (author)

  5. Simultaneous pressure-volume measurements using optical sensors and MRI for left ventricle function assessment during animal experiment.

    Science.gov (United States)

    Abi-Abdallah Rodriguez, Dima; Durand, Emmanuel; de Rochefort, Ludovic; Boudjemline, Younes; Mousseaux, Elie

    2015-01-01

    Simultaneous pressure and volume measurements enable the extraction of valuable parameters for left ventricle function assessment. Cardiac MR has proven to be the most accurate method for volume estimation. Nonetheless, measuring pressure simultaneously during MRI acquisitions remains a challenge given the magnetic nature of the widely used pressure transducers. In this study we show the feasibility of simultaneous in vivo pressure-volume acquisitions with MRI using optical pressure sensors. Pressure-volume loops were calculated while inducing three inotropic states in a sheep and functional indices were extracted, using single beat loops, to characterize systolic and diastolic performance. Functional indices evolved as expected in response to positive inotropic stimuli. The end-systolic elastance, representing the contractility index, the diastolic myocardium compliance, and the cardiac work efficiency all increased when inducing inotropic state enhancement. The association of MRI and optical pressure sensors within the left ventricle successfully enabled pressure-volume loop analysis after having respective data simultaneously recorded during the experimentation without the need to move the animal between each inotropic state. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  6. Leak detection in medium density polyethylene (MDPE) pipe using pressure transient method

    Science.gov (United States)

    Amin, M. M.; Ghazali, M. F.; PiRemli, M. A.; Hamat, A. M. A.; Adnan, N. F.

    2015-12-01

    Water is an essential part of commodity for a daily life usage for an average person, from personal uses such as residential or commercial consumers to industries utilization. This study emphasizes on detection of leaking in medium density polyethylene (MDPE) pipe using pressure transient method. This type of pipe is used to analyze the position of the leakage in the pipeline by using Ensemble Empirical Mode Decomposition Method (EEMD) with signal masking. Water hammer would induce an impulse throughout the pipeline that caused the system turns into a surge of water wave. Thus, solenoid valve is used to create a water hammer through the pipelines. The data from the pressure sensor is collected using DASYLab software. The data analysis of the pressure signal will be decomposed into a series of wave composition using EEMD signal masking method in matrix laboratory (MATLAB) software. The series of decomposition of signals is then carefully selected which reflected intrinsic mode function (IMF). These IMFs will be displayed by using a mathematical algorithm, known as Hilbert transform (HT) spectrum. The IMF signal was analysed to capture the differences. The analyzed data is compared with the actual measurement of the leakage in term of percentage error. The error recorded is below than 1% and it is proved that this method highly reliable and accurate for leak detection.

  7. Sensor for Measuring Hydrogen Partial Pressure in Parabolic Trough Power Plant Expansion Tanks

    Energy Technology Data Exchange (ETDEWEB)

    Glatzmaier, Greg C.; Cooney, Daniel A.

    2017-06-27

    The National Renewable Energy Laboratory and Acciona Energy North America are working together to design and implement a process system that provides a permanent solution to the issue of hydrogen buildup at parabolic trough power plants. We are pursuing a method that selectively removes hydrogen from the expansion tanks that serve as reservoirs for the heat transfer fluid (HTF) that circulates in the collector field and power block components. Our modeling shows that removing hydrogen from the expansion tanks at a design rate reduces and maintains dissolved hydrogen in the circulating HTF to a selected target level. Our collaborative work consists of several tasks that are needed to advance this process concept to a development stage, where it is ready for implementation at a commercial power plant. Our main effort is to design and evaluate likely process-unit operations that remove hydrogen from the expansion tanks at a specified rate. Additionally, we designed and demonstrated a method and instrumentation to measure hydrogen partial pressure and concentration in the expansion-tank headspace gas. We measured hydrogen partial pressure in the headspace gas mixture using a palladium-alloy membrane, which is permeable exclusively to hydrogen. The membrane establishes a pure hydrogen gas phase that is in equilibrium with the hydrogen in the gas mixture. We designed and fabricated instrumentation, and demonstrated its effectiveness in measuring hydrogen partial pressures over a range of three orders of magnitude. Our goal is to install this instrument at the Nevada Solar One power plant and to demonstrate its effectiveness in measuring hydrogen levels in the expansion tanks under normal plant operating conditions.

  8. Methods for measuring of fuel can deformation under radiation conditions

    International Nuclear Information System (INIS)

    Zelenchuk, A.V.; Fetisov, B.V.; Lakin, Yu.G.; Tonkov, V.Yu.

    1978-01-01

    The possibility for measuring fuel can deformation under radiation conditions by means of the acoustic method and tensoresistors is considered. The construction and operation of the in-pile facility for measuring creep of the fuel can specimen loaded by the internal pressure is described. The data on neutron radiation effect on changes in creep rate for zirconium fuel can are presented. The results obtained with tensoresistors are in a good agreement with those obtained by the acoustic method, which enables to recommend the use of both methods for the irradiation creep investigation of the fuel element cans

  9. Validation of the activity expansion method with ultrahigh pressure shock equations of state

    International Nuclear Information System (INIS)

    Rogers, F.J.; Young, D.A.

    1997-01-01

    Laser shock experiments have recently been used to measure the equation of state (EOS) of matter in the ultrahigh pressure region between condensed matter and a weakly coupled plasma. Some ultrahigh pressure data from nuclear-generated shocks are also available. Matter at these conditions has proven very difficult to treat theoretically. The many-body activity expansion method (ACTEX) has been used for some time to calculate EOS and opacity data in this region, for use in modeling inertial confinement fusion and stellar interior plasmas. In the present work, we carry out a detailed comparison with the available experimental data in order to validate the method. The agreement is good, showing that ACTEX adequately describes strongly shocked matter. copyright 1997 The American Physical Society

  10. Validation of the activity expansion method with ultrahigh pressure shock equations of state

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, F.J.; Young, D.A. [Physics Department, Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94550 (United States)

    1997-11-01

    Laser shock experiments have recently been used to measure the equation of state (EOS) of matter in the ultrahigh pressure region between condensed matter and a weakly coupled plasma. Some ultrahigh pressure data from nuclear-generated shocks are also available. Matter at these conditions has proven very difficult to treat theoretically. The many-body activity expansion method (ACTEX) has been used for some time to calculate EOS and opacity data in this region, for use in modeling inertial confinement fusion and stellar interior plasmas. In the present work, we carry out a detailed comparison with the available experimental data in order to validate the method. The agreement is good, showing that ACTEX adequately describes strongly shocked matter. {copyright} {ital 1997} {ital The American Physical Society}

  11. L-C Measurement Acquisition Method for Aerospace Systems

    Science.gov (United States)

    Woodard, Stanley E.; Taylor, B. Douglas; Shams, Qamar A.; Fox, Robert L.

    2003-01-01

    This paper describes a measurement acquisition method for aerospace systems that eliminates the need for sensors to have physical connection to a power source (i.e., no lead wires) or to data acquisition equipment. Furthermore, the method does not require the sensors to be in proximity to any form of acquisition hardware. Multiple sensors can be interrogated using this method. The sensors consist of a capacitor, C(p), whose capacitance changes with changes to a physical property, p, electrically connected to an inductor, L. The method uses an antenna to broadcast electromagnetic energy that electrically excites one or more inductive-capacitive sensors via Faraday induction. This method facilitates measurements that were not previously possible because there was no practical means of providing power and data acquisition electrical connections to a sensor. Unlike traditional sensors, which measure only a single physical property, the manner in which the sensing element is interrogated simultaneously allows measurement of at least two unrelated physical properties (e.g., displacement rate and fluid level) by using each constituent of the L-C element. The key to using the method for aerospace applications is to increase the distance between the L-C elements and interrogating antenna; develop all key components to be non-obtrusive and to develop sensing elements that can easily be implemented. Techniques that have resulted in increased distance between antenna and sensor will be presented. Fluid-level measurements and pressure measurements using the acquisition method are demonstrated in the paper.

  12. Foldable micro coils for a transponder system measuring intraocular pressure

    Energy Technology Data Exchange (ETDEWEB)

    Ullerich, S.; Schnakenberg, U. [Technische Hochschule Aachen (Germany). Inst. of Materials in Electrical Engineering 1; Mokwa, W. [Technische Hochschule Aachen (Germany). Inst. of Materials in Electrical Engineering 1]|[Fraunhofer Inst. of Microelectronic Circuits and Systems, Duisburg (Germany); Boegel, G. vom [Fraunhofer Inst. of Microelectronic Circuits and Systems, Duisburg (Germany)

    2001-07-01

    A foldable transponder system consisting of a chip and a micro coil for measuring intraocular pressure continuously is presented. The system will be integrated in the haptic of a soft artificial intraocular lens. Calculations of planar micro coils with 6 mm and 10.3 mm in diameter show the limits for planar coils with an outer diameter of 6 mm. For the realisation of the transponder system a 20 {mu}m thick coil with an outer diameter of 10.3 mm, an inner diameter of 7.7 mm, 16 turns and a gap of 20 {mu}m between the windings was selected. Measurements show a good agreement between calculated and measured values. Wireless pressure measurements were carried out showing a linear behaviour of the output signal with respect to the applied pressure. (orig.)

  13. Methods and Systems for Configuring Sensor Acquisition Based on Pressure Steps

    Science.gov (United States)

    DeDonato, Mathew (Inventor)

    2015-01-01

    Technologies are provided for underwater measurements. A system includes an underwater vessels including: a plurality of sensors disposed thereon for measuring underwater properties; and a programmable controller configured to selectively activate the plurality of sensors based at least in part on underwater pressure. A user may program at what pressure ranges certain sensors are activated to measure selected properties, and may also program the ascent/descent rate of the underwater vessel, which is correlated with the underwater pressure.

  14. Cascading pressure reactor and method for solar-thermochemical reactions

    Science.gov (United States)

    Ermanoski, Ivan

    2017-11-14

    Reactors and methods for solar thermochemical reactions are disclosed. The reactors and methods include a cascade of reduction chambers at successively lower pressures that leads to over an order of magnitude pressure decrease compared to a single-chambered design. The resulting efficiency gains are substantial, and represent an important step toward practical and efficient solar fuel production on a large scale.

  15. Pancreatic tissue fluid pressure and pain in chronic pancreatitis

    DEFF Research Database (Denmark)

    Ebbehøj, N

    1992-01-01

    A casual relation between pancreatic pressure and pain has been searched for decades but lack of appropriate methods for pressure measurements has hindered progress. During the 1980's the needle method has been used for direct intraoperative pancreatic tissue fluid pressure measurements and later...... for percutaneous sonographically-guided pressure measurements. Clinical and experimental evaluation of the method showed comparable results at intraoperative and percutaneous measurements and little week-to-week variation. Furthermore, comparable pressures in duct and adjacent pancreatic tissue were found, i.......e. the needle pressure mirrors the intraductal pressure. Comparisons of pain registrations, morphological and functional parameters with pancreatic tissue fluid pressure measurements have revealed a relation between pressure and pain which probably is causal. In patients with pain the high pressures previously...

  16. PIEZOELECTRIC WAVEGUIDE SENSOR FOR MEASURING PULSE PRESSURE IN CLOSED LIQUID VOLUMES AT HIGH VOLTAGE ELECTRIC DISCHARGE

    Directory of Open Access Journals (Sweden)

    V. G. Zhekul

    2017-10-01

    Full Text Available Purpose. Investigations of the characteristics of pressure waves presuppose the registration of the total profile of the pressure wave at a given point in space. For these purposes, various types of «pressure to the electrical signal» transmitters (sensors are used. Most of the common sensors are unsuitable for measuring the pulse pressure in a closed water volume at high hydrostatic pressures, in particular to study the effect of a powerful high-voltage pulse discharge on increasing the inflow of minerals and drinking water in wells. The purpose of the work was to develop antijamming piezoelectric waveguide sensor for measuring pulse pressure at a close distance from a high-voltage discharge channel in a closed volume of a liquid. Methodology. We have applied the calibration method as used as a secondary standard, the theory of electrical circuits. Results. We have selected the design and the circuit solution of the waveguide pressure sensor. We have developed a waveguide pulse-pressure sensor DTX-1 with a measuring loop. This sensor makes it possible to study the spectral characteristics of pressure waves of high-voltage pulse discharge in closed volumes of liquid at a hydrostatic pressure of up to 20 MPa and a temperature of up to 80 °C. The sensor can be used to study pressure waves with a maximum amplitude value of up to 150 MPa and duration of up to 80 µs. According to the results of the calibration, the sensitivity of the developed sensor DTX-1 with a measuring loop is 0.0346 V/MPa. Originality. We have further developed the theory of designing the waveguide piezoelectric pulse pressure sensors for measuring the pulse pressure at a close distance from a high-voltage discharge channel in a closed fluid volume by controlling the attenuation of the amplitude of the pressure signal. Practical value. We have developed, created, calibrated, used in scientific research waveguide pressure pulse sensors DTX-1. We propose sensors DTX-1 for sale

  17. Nuclear power plant pressurizer fault diagnosis using fuzzy signed-digraph method

    International Nuclear Information System (INIS)

    Park, Joo Hyun; Seong, Poong Hyun

    2004-01-01

    In this study, The Fuzzy Signed Digraph method which has been researched and applied to the chemical process is improved and applied to the fault diagnosis of the pressurizer in nuclear power plants. The Fuzzy Signed-Digraph (FSD) is the method which applies the fuzzy number to the Signed-Digraph (SDG) method. The current SDG methods have many merits as follows: (1) SDG method can directly use the value of sensors not the alarm to the fault diagnosis. (2) This method can diagnose the fault independent on the pattern. (3) This method can diagnose the faults fastly because the method uses the cause-effect relation instead of the complex control equation among the variables. But, they are not proper to be applied to the diagnosis of the multi-faults and to diagnose faults on real time. It is because the unmeasured nodes in those methods must be connected to each other in order to find out the single fault under the single-fault assumption. These methods need long CPU time and cannot be applied to the multi-faults diagnosis. We propose a method in which the values of the unmeasured nodes are calculated from the relations between the unmeasured nodes and the measured nodes. By using this method, the CPU time for diagnosis can be reduced. This CPU time reduction makes the real-time diagnosis possible. This method can also be applied for the multi-faults diagnosis. This method is applied to the diagnosis of the pressurizer of the nuclear power plant KORI-2 in Korea. (author)

  18. Critical Assessment of the Surface Tension determined by the Maximum Pressure Bubble Method

    OpenAIRE

    Benedetto, Franco Emmanuel; Zolotucho, Hector; Prado, Miguel Oscar

    2015-01-01

    The main factors that influence the value of surface tension of a liquid measured with the Maximum Pressure Bubble Method are critically evaluated. We present experimental results showing the effect of capillary diameter, capillary depth, bubble spheroidicity and liquid density at room temperature. We show that the decrease of bubble spheroidicity due to increase of capillary immersion depth is not sufficient to explain the deviations found in the measured surface tension values. Thus, we pro...

  19. Alternative methods for measuring obesity in African American women.

    Science.gov (United States)

    Clark, Ashley E; Taylor, Jacquelyn Y; Wu, Chun Yi; Smith, Jennifer A

    2013-03-01

    The use of body mass index (BMI) may not be the most appropriate measurement tool in determining obesity in diverse populations. We studied a convenience sample of 108 African American (AA) women to determine the best method for measuring obesity in this at-risk population. The purpose of this study was to determine if percent body fat (PBF) and percent body water (PBW) could be used as alternatives to BMI in predicting obesity and risk for hypertension (HTN) among AA women. After accounting for age, BMI, and the use of anti-hypertensive medication, PBF (p = 0.0125) and PBW (p = 0.0297) were significantly associated with systolic blood pressure, while BMI was not. Likewise, PBF (p = 0.0316) was significantly associated with diastolic blood pressure, while PBW and BMI were not. Thus, health care practitioners should consider alternative anthropometric measurements such as PBF when assessing obesity in AA women.

  20. A calculation and uncertainty evaluation method for the effective area of a piston rod used in quasi-static pressure calibration

    Science.gov (United States)

    Gu, Tingwei; Kong, Deren; Shang, Fei; Chen, Jing

    2018-04-01

    This paper describes the merits and demerits of different sensors for measuring propellant gas pressure, the applicable range of the frequently used dynamic pressure calibration methods, and the working principle of absolute quasi-static pressure calibration based on the drop-weight device. The main factors affecting the accuracy of pressure calibration are analyzed from two aspects of the force sensor and the piston area. To calculate the effective area of the piston rod and evaluate the uncertainty between the force sensor and the corresponding peak pressure in the absolute quasi-static pressure calibration process, a method for solving these problems based on the least squares principle is proposed. According to the relevant quasi-static pressure calibration experimental data, the least squares fitting model between the peak force and the peak pressure, and the effective area of the piston rod and its measurement uncertainty, are obtained. The fitting model is tested by an additional group of experiments, and the peak pressure obtained by the existing high-precision comparison calibration method is taken as the reference value. The test results show that the peak pressure obtained by the least squares fitting model is closer to the reference value than the one directly calculated by the cross-sectional area of the piston rod. When the peak pressure is higher than 150 MPa, the percentage difference is less than 0.71%, which can meet the requirements of practical application.

  1. Radon decay product in-door behaviour - parameter, measurement method, and model review

    International Nuclear Information System (INIS)

    Scofield, P.

    1988-01-01

    This report reviews parameters used to characterize indoor radon daughter behavior and concentrations. Certain parameters that affect indoor radon daughter concentrations are described and the values obtained experimentally or theoretically are summarized. Radon daughter measurement methods are reviewed, such as, PAEC, unattached daughters, particle size distributions, and plateout measurement methods. In addition, certain radon pressure driven/diffusion models and indoor radon daughter models are briefly described. (orig.)

  2. Pressure pulsation measurements in pipe and cluster flows

    International Nuclear Information System (INIS)

    Benemann, A.; Voj, P.

    1976-01-01

    Measuring and evaluation techniques of pressure pulsations in pipe and cluster flows are described. The measurements were made on a 1 m long SNR rod-cluster and its feed and drain pipes. At Reynolds numbers in the cluster of 8.9 x 10 4 flow velocities of 14 m/sec were achieved. With the aid of a block diagram recording of the measured values by piezoelectric crystal and piezo-resistive strain gange as well as data processing are explained. For the analytical treatment of the pressure pulsation signals characterizing the turbulence field computer codes of a digital computer and a fast-fourier analyzer (Hewlett-Packard 5450 A) were used. The results show good agreement with theoretical curves on the behaviour of turbulent boundary layers of cluster and pipe flows at high Reynolds numbers. (TK) [de

  3. Digital photography and transparency-based methods for measuring wound surface area.

    Science.gov (United States)

    Bhedi, Amul; Saxena, Atul K; Gadani, Ravi; Patel, Ritesh

    2013-04-01

    To compare and determine a credible method of measurement of wound surface area by linear, transparency, and photographic methods for monitoring progress of wound healing accurately and ascertaining whether these methods are significantly different. From April 2005 to December 2006, 40 patients (30 men, 5 women, 5 children) admitted to the surgical ward of Shree Sayaji General Hospital, Baroda, had clean as well as infected wound following trauma, debridement, pressure sore, venous ulcer, and incision and drainage. Wound surface areas were measured by these three methods (linear, transparency, and photographic methods) simultaneously on alternate days. The linear method is statistically and significantly different from transparency and photographic methods (P value transparency and photographic methods (P value >0.05). Photographic and transparency methods provided measurements of wound surface area with equivalent result and there was no statistically significant difference between these two methods.

  4. Containment pressure monitoring method after severe accident in nuclear power plant

    International Nuclear Information System (INIS)

    Luo Chuanjie; Zhang Shishui

    2011-01-01

    The containment atmosphere monitoring system in nuclear power plant was designed on the basis of design accident. But containment pressure will increase greatly in a severe accident, and pressure instrument in the containment can't satisfy the monitoring requirement. A new method to monitor the pressure change in the containment after a severe accident was considered, through which accident soften methods can be adopted. Under present technical condition, adding a pressure monitoring channel out of containment for post-severe accident is a considerable method. Daya Bay Nuclear Power Plant implemented this modification, by which the containment release time can be delayed during severe accident, and nuclear safety can be increased. After analysis, this method is safe and feasible. (authors)

  5. The determination of the pressure-viscosity coefficient of two traction oils using film thickness measurements

    NARCIS (Netherlands)

    Leeuwen, van H.J.

    2010-01-01

    The pressure-viscosity coefficients of two commercial traction fluids are determined by fitting calculation results on accurate film thickness measurements, obtained at a wide range of speeds, and different temperatures. Film thickness values are calculated using a numerical method and approximation

  6. Prevalence of masked uncontrolled hypertension according to the number of office blood pressure measurements.

    Science.gov (United States)

    Vinyoles, E; Camafort, M; Domenech, M; Coca, A; Sobrino, J

    2015-11-01

    The reported prevalence of masked uncontrolled hypertension (MUCH) varies because many studies are not comparable as they use different measurement methodologies. To evaluate the influence of the number of office blood pressure readings on the prevalence of MUCH we conducted a cross-sectional, multicenter study in treated hypertensive patients. We carried out an observational, cross-sectional, multicenter study in 33 Spanish hospital-based hypertension units, involving 35 investigators and 12 Autonomous Communities. Six blood pressure readings and a 24-h ambulatory blood pressure monitoring were performed in treated hypertensive patients. The means of the first 3 readings (P123), the 2nd, 3rd and 4th readings (P234), the 3rd, 4th and 5th readings (P345) and the last 3 readings (P456) were compared with mean 24-h blood pressure. MUCH was defined as office blood pressure <140/90mmHg and 24-h blood pressure ≥130/80mmHg, considering the first 3 readings (MUCH123), the 2nd, 3rd and 4th readings (MUCH234), the 3rd, 4th and 5th readings (MUCH345) and the last 3 readings (MUCH456). We included 498 hypertensive patients. Mean (standard deviation) office blood pressure measurements were: (P123) 141(18)/82(11); (P234) 139(17)/81(11); (P345) 138(17)/81(11) and (P456) 137(16)/80(10) mmHg. Mean 24-h blood pressure was 127(13.8)/75(9.5) mmHg. The correlation coefficients between ambulatory and office systolic/diastolic blood pressure were (P123):0.48/0.50; (P234):0.50/0.52; (P345):0.50/0.54; and (P456):0.50/0.55 (p<0.001, all). The prevalences of MUCH123, MUCH234, MUCH345 and MUCH456 were 14.5%, 18.9%, 19.5% and 21.1%, respectively. The prevalence of MUCH diagnosis depends on the serial office blood pressure readings, being much higher for the last three blood pressure readings. Discarding the first and second office blood pressure measures seems to be the most accurate method for diagnosing MUCH. Copyright © 2015 Elsevier España, S.L.U. y Sociedad Española de Medicina

  7. Evaluation of Pressure Pain Threshold as a Measure of Perceived Stress and High Job Strain

    DEFF Research Database (Denmark)

    Hven, Lisbeth; Frost, Poul; Bonde, Jens Peter Ellekilde

    2017-01-01

    OBJECTIVE: To investigate whether pressure pain threshold (PPT), determined by pressure algometry, can be used as an objective measure of perceived stress and job strain. METHODS: We used cross-sectional base line data collected during 1994 to 1995 within the Project on Research and Intervention...... in Monotonous work (PRIM), which included 3123 employees from a variety of Danish companies. Questionnaire data included 18 items on stress symptoms, 23 items from the Karasek scale on job strain, and information on discomfort in specified anatomical regions was also collected. Clinical examinations included...... pressure pain algometry measurements of PPT on the trapezius and supraspinatus muscles and the tibia. Associations of stress symptoms and job strain with PPT of each site was analyzed for men and women separately with adjustment for age body mass index, and discomfort in the anatomical region closest...

  8. Experimental research on charging characteristics of a solar photovoltaic system by the pressure-control method

    Institute of Scientific and Technical Information of China (English)

    Hua ZHU; Zhang-lu XU; Zi-juan CAO

    2011-01-01

    The charging characteristics of the valve-regulated lead acid (VRLA) battery driven by solar energy were experimentally studied through the pressure-control method in this paper. The aims of the research were to increase charging efficiency to make the most of solar energy and to improve charging quality to prolong life of battery. The charging process of a 12 V 12 A.h VRLA battery has been tested under the mode of a stand-alone photovoltaic (PV) system. Results show that the pressure-control method can effectively control PV charging of the VRLA battery and make the best of PV cells through the maximum power point tracking (MPPT). The damage of VRLA battery by excess oxygen accumulation can be avoided through the inner pressure control of VRLA battery. Parameters such as solar radiation intensity, charging power, inner pressure of the battery, and charging current and voltage during the charging process were measured and analyzed.

  9. Pressure-induced magnetic transition in Fe sub 4 N probed by Fe K-edge XMCD measurement

    CERN Document Server

    Ishimatsu, N; Maruyama, H; Kawamura, N; Suzuki, M; Ohishi, Y; Ito, M; Nasu, S; Kawakami, T

    2003-01-01

    X-ray magnetic circular dichroism (XMCD) of gamma'-iron nitride (Fe sub 4 N) was recorded at Fe K-edge under high pressure up to 27 GPa. The XMCD intensity decreased remarkably with pressure, and vanished at 24 GPa. Compressibility was measured by the X-ray diffraction method. These results indicate that Fe sub 4 N undergoes a second-order phase transition from the ferromagnetic state to a paramagnetic state without any structural change. The pressure-induced demagnetizing process is discussed in terms of the Fe magnetic states in the local environment.

  10. Comparison of three protocols for measuring the maximal respiratory pressures

    Directory of Open Access Journals (Sweden)

    Isabela Maria B. Sclauser Pessoa

    Full Text Available Introduction To avoid the selection of submaximal efforts during the assessment of maximal inspiratory and expiratory pressures (MIP and MEP, some reproducibility criteria have been suggested. Criteria that stand out are those proposed by the American Thoracic Society (ATS and European Respiratory Society (ERS and by the Brazilian Thoracic Association (BTA. However, no studies were found that compared these criteria or assessed the combination of both protocols. Objectives To assess the pressure values selected and the number of maneuvers required to achieve maximum performance using the reproducibility criteria proposed by the ATS/ERS, the BTA and the present study. Materials and method 113 healthy subjects (43.04 ± 16.94 years from both genders were assessed according to the criteria proposed by the ATS/ERS, BTA and the present study. Descriptive statistics were used for analysis, followed by ANOVA for repeated measures and post hoc LSD or by Friedman test and post hoc Wilcoxon, according to the data distribution. Results The criterion proposed by the present study resulted in a significantly higher number of maneuvers (MIP and MEP – median and 25%-75% interquartile range: 5[5-6], 4[3-5] and 3[3-4] for the present study criterion, BTA and ATS/ERS, respectively; p < 0.01 and higher pressure values (MIP – mean and 95% confidence interval: 103[91.43-103.72], 100[97.19-108.83] and 97.6[94.06-105.95]; MEP: median and 25%-75% interquartile range: 124.2[101.4-165.9], 123.3[95.4-153.8] and 118.4[95.5-152.7]; p < 0.05. Conclusion The proposed criterion resulted in the selection of pressure values closer to the individual’s maximal capacity. This new criterion should be considered in future studies concerning MIP and MEP measurements.

  11. On-line fast response device and method for measuring dissolved gas in a fluid

    Science.gov (United States)

    Tutu, Narinder Kumar [Manorville, NY

    2011-01-11

    A method and device for the measurement of dissolved gas within a fluid. The fluid, substantially a liquid, is pumped into a pipe. The flow of the fluid is temporally restricted, creating one or more low pressure regions. A measurement indicative of trapped air is taken before and after the restriction. The amount of dissolved air is calculated from the difference between the first and second measurements. Preferably measurements indicative of trapped air is obtained from one or more pressure transducers, capacitance transducers, or combinations thereof. In the alternative, other methods such as those utilizing x-rays or gamma rays may also be used to detect trapped air. Preferably, the fluid is a hydraulic fluid, whereby dissolved air in the fluid is detected.

  12. Pressure-induced magneto-structural transition in iron via a modified solid-state nudged elastic band method

    Science.gov (United States)

    Zarkevich, Nikolai A.; Johnson, Duane D.

    2015-03-01

    Materials under pressure may exhibit critical electronic and structural transitions that affect equation of states, as known for superconductors and the magneto-structural transformations of iron with both geophysical and planetary implications. While experiments often use constant-pressure (diamond-anvil cell, DAC) measurements, many theoretical results address a constant-volume transitions, which avoid issues with magnetic collapse but cannot be directly compared to experiment. We establish a modified solid-state nudge elastic band (MSS-NEB) method to handle magnetic systems that may exhibit moment (and volume) collapse during transformation. We apply it to the pressure-induced transformation in iron between the low-pressure body-centered cubic (bcc) and the high-pressure hexagonal close-packed (hcp) phases, find the bcc-hcp equilibrium coexistence pressure and a transitional pathway, and compare to shock and DAC experiments. We use methods developed with support by the U.S. Department of Energy (DE-FG02-03ER46026 and DE-AC02-07CH11358). Ames Laboratory is operated for the DOE by Iowa State University under contract DE-AC02-07CH11358.

  13. Development of computational methods of design by analysis for pressure vessel components

    International Nuclear Information System (INIS)

    Bao Shiyi; Zhou Yu; He Shuyan; Wu Honglin

    2005-01-01

    Stress classification is not only one of key steps when pressure vessel component is designed by analysis, but also a difficulty which puzzles engineers and designers at all times. At present, for calculating and categorizing the stress field of pressure vessel components, there are several computation methods of design by analysis such as Stress Equivalent Linearization, Two-Step Approach, Primary Structure method, Elastic Compensation method, GLOSS R-Node method and so on, that are developed and applied. Moreover, ASME code also gives an inelastic method of design by analysis for limiting gross plastic deformation only. When pressure vessel components design by analysis, sometimes there are huge differences between the calculating results for using different calculating and analysis methods mentioned above. As consequence, this is the main reason that affects wide application of design by analysis approach. Recently, a new approach, presented in the new proposal of a European Standard, CEN's unfired pressure vessel standard EN 13445-3, tries to avoid problems of stress classification by analyzing pressure vessel structure's various failure mechanisms directly based on elastic-plastic theory. In this paper, some stress classification methods mentioned above, are described briefly. And the computational methods cited in the European pressure vessel standard, such as Deviatoric Map, and nonlinear analysis methods (plastic analysis and limit analysis), are depicted compendiously. Furthermore, the characteristics of computational methods of design by analysis are summarized for selecting the proper computational method when design pressure vessel component by analysis. (authors)

  14. A non-destructive, ultrasonic method for the determination of internal pressure and gas composition in an LWR fuel rod on-going and future programme

    International Nuclear Information System (INIS)

    Ferrandis, J.; Leveque, G.; Villard, J.

    2006-01-01

    Several possible non-destructive methods have been investigated in the past to measure the internal gas pressure e.g., measurement of 85 Kr directly, or after accumulation in the plenum by freezing with liquid nitrogen. However no satisfactory resolution to the problem has been found, so at present there is no rapid and accurate method of determining the fission gas pressure in a fuel rod without puncturing the cladding. This procedure is time-consuming and expensive and as a consequence a relatively small number of measurements are generally made compared with the number of fuel rods irradiated. In this paper it is proposed a new method for the measurement of pressure that is: Non-destructive; Non-invasive (i.e., allows re-irradiation of the measured rod); Easy to operate - directly in the reactor pool; Can be used on the critical path; Is inexpensive compared with the methods currently in use. This method is also being adapted to the on line measurement of fission gas release on fuel irradiation in research reactors. This method is based on the application of acoustic technology

  15. Blood pressure self-measurement in the obstetric waiting room

    DEFF Research Database (Denmark)

    Wagner, Stefan; Kamper, Christina H.; Toftegaard, Thomas Skjødeberg

    2013-01-01

    a reliable blood pressure reading. Results: We found that the patients did not adhere to given instructions when performing blood pressure self-measurement in the waiting room. None of the 81 patients adhered to all six inves- tigated recommendations, while around a quarter adhered to five out of six...

  16. Method and device for measuring fluid flow

    International Nuclear Information System (INIS)

    Atherton, R.; Marinkovich, P.S.; Spadaro, P.R.; Stout, J.W.

    1976-01-01

    The invention is a fluid flow measuring device for determining the coolant flow at the entrance to a specific nuclear reactor fuel region. The device comprises a plurality of venturis having the upstream inlet and throat pressure of each respectively manifolded together to provide one static pressure signal for each region monitored. The device provides accurate flow measurement with low pressure losses and uniform entrance and discharge flow distribution. 1 claim, 7 figures

  17. The position of the arm during blood pressure measurement in sitting position.

    Science.gov (United States)

    Adiyaman, Ahmet; Verhoeff, Rutger; Lenders, Jacques W M; Deinum, Jaap; Thien, Theo

    2006-12-01

    Determining the influence of the position of the arm on blood pressure measurement in the sitting position. Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in two different positions. First, both arms were placed at the chair support level and blood pressure was measured three times on both arms after 10 min of rest. Subsequently, while still remaining in the same sitting position, five blood pressure measurements were made simultaneously at both arms with one arm placed on the desk and one arm placed and supported at heart level (mid-sternal). The arm placed at heart level served as the reference arm. The choice of which arm was placed at desk level and which arm was placed at heart level was randomized. Both at desk level and at chair support level, mean (+/-SD) systolic and diastolic blood pressures were higher than blood pressure at heart level by 6.1/5.7+/-4.6/3.1 and 9.3/9.4+/-5.4/3.4 mmHg, respectively. The effect of the height differences between the arm positions on the blood pressure readings was smaller than predicted (0.49 mmHg/cm systolic and 0.47 mmHg/cm diastolic). No significant correlation was found between blood pressure difference in the different arm positions (desk and heart level) and age, sex, weight or baseline blood pressure. Different arm positions below heart level have significant effects on blood pressure readings. The leading guidelines about arm position during blood pressure measurement are not in accordance with the arm position used in the Framingham study, the most frequently used study for risk estimations.

  18. Calculation method for residual stress analysis of filament-wound spherical pressure vessels

    International Nuclear Information System (INIS)

    Knight, C.E. Jr.

    1976-01-01

    Filament wound spherical pressure vessels may be produced with very high performance factors. These performance factors are a calculation of contained pressure times enclosed volume divided by structure weight. A number of parameters are important in determining the level of performance achieved. One of these is the residual stress state in the fabricated unit. A significant level of an unfavorable residual stress state could seriously impair the performance of the vessel. Residual stresses are of more concern for vessels with relatively thick walls and/or vessels constructed with the highly anisotropic graphite or aramid fibers. A method is established for measuring these stresses. A theoretical model of the composite structure is required. Data collection procedures and techniques are developed. The data are reduced by means of the model and result in the residual stress analysis. The analysis method can be used in process parameter studies to establish the best fabrication procedures

  19. Measuring occupational stress: development of the pressure management indicator.

    Science.gov (United States)

    Williams, S; Cooper, C L

    1998-10-01

    The study of occupational stress is hindered by the lack of compact and comprehensive standardized measurement tools. The Pressure Management Indicator (PMI) is a 120-item self-report questionnaire developed from the Occupational Stress Indicator (OSI). The PMI is more reliable, more comprehensive, and shorter than the OSI. It provides an integrated measure of the major dimensions of occupational stress. The outcome scales measure job satisfaction, organizational satisfaction, organizational security, organizational commitment, anxiety--depression, resilience, worry, physical symptoms, and exhaustion. The stressor scales cover pressure from workload, relationships, career development, managerial responsibility, personal responsibility, home demands, and daily hassles. The moderator variables measure drive, impatience, control, decision latitude, and the coping strategies of problem focus, life work balance, and social support.

  20. Reliability and responsiveness of algometry for measuring pressure pain threshold in patients with knee osteoarthritis.

    Science.gov (United States)

    Mutlu, Ebru Kaya; Ozdincler, Arzu Razak

    2015-06-01

    [Purpose] This study aimed to establish the intrarater reliability and responsiveness of a clinically available algometer in patients with knee osteoarthritis as well as to determine the minimum-detectable-change and standard error of measurement of testing to facilitate clinical interpretation of temporal changes. [Subjects] Seventy-three patients with knee osteoarthritis were included. [Methods] Pressure pain threshold measured by algometry was evaluated 3 times at 2-min intervals over 2 clinically relevant sites-mediolateral to the medial femoral tubercle (distal) and lateral to the medial malleolus (local)-on the same day. Intrarater reliability was estimated by intraclass correlation coefficients. The minimum-detectable-change and standard error of measurement were calculated. As a measure of responsiveness, the effect size was calculated for the results at baseline and after treatment. [Results] The intrarater reliability was almost perfect (intraclass correlation coefficient = 0.93-0.97). The standard error of measurement and minimum-detectable-change were 0.70-0.66 and 1.62-1.53, respectively. The pressure pain threshold over the distal site was inadequately responsive in knee osteoarthritis, but the local site was responsive. The effect size was 0.70. [Conclusion] Algometry is reliable and responsive to assess measures of pressure pain threshold for evaluating pain patients with knee osteoarthritis.

  1. A family of fiber-optic based pressure sensors for intracochlear measurements

    Science.gov (United States)

    Olson, Elizabeth S.; Nakajima, Hideko H.

    2015-02-01

    Fiber-optic pressure sensors have been developed for measurements of intracochlear pressure. The present family of transducers includes an 81 μm diameter sensor employing a SLED light source and single-mode optic fiber, and LED/multi-mode sensors with 126 and 202 μm diameter. The 126 μm diameter pressure sensor also has been constructed with an electrode adhered to its side, for coincident pressure and voltage measurements. These sensors have been used for quantifying cochlear mechanical impedances, informing our understanding of conductive hearing loss and its remediation, and probing the operation of the cochlear amplifier.

  2. The calibration of a cylindrical pressure probe for recirculating flow measurements

    International Nuclear Information System (INIS)

    Lawn, C.J.

    1975-06-01

    The use of the pressure distribution around a cylinder in cross-flow to indicate the magnitude and direction of the velocity vector is discussed in the context of making measurements in highly turbulent recirculating flows. The intended application is the measurement of the flow between the ribs on the large-scale model of the AGR fuel-pin surface. Results from a number of calibration experiments in boundary layers are used to provide a correlation for the positions at which local static pressure is measured on the cylinder surface. After appropriate corrections, the dynamic pressure is deduced from the pressure at the stagnation point. Corrections are also necessary in deducing the direction of flow from the bisector of the static pressure positions, when the cylinder is in a shear flow or near a wall, and these too are evaluated from the results of the calibration experiments. Measurements in two recirculating flows are then presented as an illustration both of the validity and limitations of the technique. In the first case, comparison is made with the measurements of a pulsed-wire anemometer behind a surface-mounted cube and, in the second, the continuity is used to provide an overall check on measurements behind a transverse plate. It is concluded that useful results can be obtained in many turbulent flow situations. (author)

  3. Intraocular pressure measurement over soft contact lens by rebound tonometer: a comparative study.

    Science.gov (United States)

    Nacaroglu, Senay Asik; Un, Emine Seker; Ersoz, Mehmet Giray; Tasci, Yelda

    2015-01-01

    To evaluate the intraocular pressure (IOP) measurements by Icare rebound tonometer over a contact lens in comparison with Goldmann applanation tonometry (GAT). Fifty patients using contact lens were included in this study. One of the eyes of the patients was selected randomly and their IOP were measured by rebound tonometer with and without contact lens (RTCL, RT respectively) and by GAT, as well as their central corneal thickness (CCT) by optical pachymeter. The results of both methods were compared by correlation analysis, general linear method repeated measure and Bland-Altman analysis. Mean IOP values measured by RTCL, RT and GAT were 15.68±3.7, 14.50±3.4 and 14.16±2.8 (Pcontact lens by rebound tonometer was found to be higher than what was measured by GAT. Although this difference is statistically significant, it may be clinically negligible in the normal population.

  4. Interfacial tension measurement between CO2 and brines under high temperature and elevated pressure conditions

    Science.gov (United States)

    Li, X.; Boek, E. S.; Maitland, G. C.; Trusler, J. P. M.

    2012-04-01

    We have investigated the dependence of interfacial tension of (CO2 + brine) on temperature, pressure and salinity (including both salt type and molality) over the range of conditions applicable to CO2 storage in saline aquifers. The study covered a wide range of measurements of the interfacial tensions between carbon dioxide and (NaCl + KCl)(aq), CaCl2(aq), MgCl2(aq), Na2SO4(aq), KHCO3(aq), NaHCO3(aq) and two laboratory constructed brines with molality ranging from (0.3 to 5.0) mol·kg-1. The measurements were made at temperatures between (298 and 448) K at various pressures up to 50 MPa, using the pendant drop method in a high-pressure view cell filled with water-saturated CO2. The drop to be imaged was created by injecting brine from a high-pressure syringe pump into a capillary sealed through the top of the cell. The expanded uncertainties of the experimental state variables at 95 % confidence are +0.05 K in temperature and +70 kPa in pressure. For the interfacial tension, the overall expanded relative uncertainty at 95 % confidence was +1.6%. The experimental results show that interfacial tension for all the systems increases linearly with molality, indicating that relatively few measurements and simple interpolation procedures are adequate for describing this property accurately over wide ranges of conditions.

  5. High temperature and high pressure gas cell for quantitative spectroscopic measurements

    DEFF Research Database (Denmark)

    Christiansen, Caspar; Stolberg-Rohr, Thomine; Fateev, Alexander

    2016-01-01

    A high temperature and high pressure gas cell (HTPGC) has been manufactured for quantitative spectroscopic measurements in the pressure range 1-200 bar and temperature range 300-1300 K. In the present work the cell was employed at up to 100 bar and 1000 K, and measured absorption coefficients...... of a CO2-N2 mixture at 100 bar and 1000 K are revealed for the first time, exceeding the high temperature and pressure combinations previously reported. This paper discusses the design considerations involved in the construction of the cell and presents validation measurements compared against simulated...

  6. MEASUREMENT OF ENDOTRACHEAL TUBE CUFF PRESSURE IN MECHANICALLYVENTILATED PATIENTS ON ARRIVAL TO INTENSIVE CARE UNIT - A CROSS-SECTIONAL STUDY

    Directory of Open Access Journals (Sweden)

    Arun Kumar Ajjappa

    2017-04-01

    Full Text Available BACKGROUND The monitoring of Endotracheal Tube (ETT cuff pressure in intubated patients on arrival to intensive care unit is very essential. The cuff pressure must be within an optimal range of 20-30cm H2O ensuring ventilation with no complications related to cuff overinflation and underinflation. This can be measured with a cuff pressure manometer. The aim of the study is to measure the endotracheal tube cuff pressure in patients on arrival to intensive care unit and to identify prevalence of endotracheal cuff underinflation and overinflation. MATERIALS AND METHODS A cross-sectional study was done on mechanically-ventilated patients who were intubated in casualty (emergency department on arrival to intensive care unit in S.S. Institute of Medical Sciences and Research Centre, Davangere. About 50 critically-ill patients intubated with a high volume, low pressure endotracheal tube were included in the study. An analogue manometer was used to measure the endotracheal tube cuff pressure. It was compared with the recommended level. The settings of mechanical ventilation, endotracheal tube size and peak airway pressure were recorded. RESULTS It was found that the mean cuff pressure was 64.10 cm of H2O with a standard deviation of 32.049. Of the measured cuff pressures, only 2% had pressures within an optimal range (20-30cm of H2O. 88% had cuff pressures more than 30cm of H2O. The mean peak airway pressure found to be 20.50cm of H2O with a Standard Deviation (SD of 5.064. CONCLUSION This study is done to emphasise the importance of cuff pressure measurement in all mechanically-ventilated patients as cuff pressure is found to be high in most of the patients admitted to intensive care unit. Complications of overinflation and underinflation can only be prevented if the acceptable cuff pressures are achieved.

  7. A Method for Recording Urethral Pressure Profiles in Female Rats.

    Directory of Open Access Journals (Sweden)

    Shengfei Xu

    Full Text Available Urethral pressure profile (UPP and leak-point pressure (LPP measurements as well as external urethral sphincter (EUS electromyography (EMG and videourodynamic analyses are the primary methods for evaluating urethral function in humans. However, UPP recording in female rats, a widely used animal model, is challenging due to their small body sizes. This study reports a novel method for recording UPP in female rats.Seventeen anesthetized female rats were studied. LPP data for 14 rats were included. The other 3 rats were excluded because of death or abnormal urogenital organs. UPP curves were recorded using a modified water-perfusion catheter system, with the lateral hole facing the 3-, 6-, 9-, and 12-o'clock positions in a randomized sequence. LPP, functional urethral length (FUL and maximum urethral closure pressure (MUCP were analyzed.The mean LPP was 64.39 ± 20.29 cm H2O. The mean FUL and MUCP values at the 3-, 6-, 9-, and 12-o'clock positions were 12.90 ± 1.20, 16.70 ± 1.95, 13.90 ± 2.42, and 11.60 ± 0.97 mm, respectively, and 38.70 ± 11.85, 33.90 ± 11.82, 37.40 ± 11.95, and 71.90 ± 23.01 cm H2O, respectively. The FUL at the 6-o'clock position and MUCP at the 12-o'clock position were significantly greater than those at the other 3 positions. The FUL and MUCP of repeated UPP recordings were not significantly different than those of the first recordings.UPP recording using a modified method based on a water-perfusion catheter system is feasible and replicable in female rats. It produces UPP curves that sensitively and appreciably reflect detailed pressure changes at different points within the urethra and thus provides opportunity to evaluate urethral structures, especially the urethral sphincter, in detail. These results may enhance the utility of female rat models in research of urinary sphincter mechanisms.

  8. Student measurement of blood pressure using a simulator arm compared with a live subject's arm.

    Science.gov (United States)

    Lee, Jennifer J; Sobieraj, Diana M; Kuti, Effie L

    2010-06-15

    To compare accuracy of blood pressure measurements using a live subject and a simulator arm, and to determine students' preferences regarding measurement. This was a crossover study comparing blood pressure measurements from a live subject and a simulator arm. Students completed an anonymous survey instrument defining opinions on ease of measurement. Fifty-seven students completed blood pressure measurements on live subjects while 72 students completed blood pressure measurements using the simulator arm. There were no significant systematic differences between the 2 measurement techniques. Systolic blood pressure measurements from a live subject arm were less likely to be within 4 mm Hg compared with measurements of a simulator arm. Diastolic blood pressure measurements were not significantly different between the 2 techniques. Accuracy of student measurement of blood pressure using a simulator arm was similar to the accuracy with a live subject. There was no difference in students' preferences regarding measurement techniques.

  9. A Method of Estimating Pressure and Intensity Distributions of Multielement Phased Array High Intensity Focused Ultrasonic Field at Full Power Using a Needle Hydrophone

    International Nuclear Information System (INIS)

    Yu Ying; Shen Guofeng; Bai Jingfeng; Chen Yazhu

    2011-01-01

    The pressure and intensity distribution of high intensity focused ultrasound (HIFU) fields at full power are critical for predicting heating patterns and ensuring safety of the therapy. With the limitations of maximum pressure at the hydrophone and damage from cavitation or thermal effects, it is hard to measure pressure and intensity directly when HIFU is at full power. HIFU-phased arrays are usually composed of large numbers of small elements and the sound power radiated from some of them at full power is measureable using a hydrophone, we grouped them based on the limitation of maximum permissible pressure at the hydrophone and the characteristics of the element arrangement in the array. Then sound field measurement of the group was carried out at full power level. Using the acoustic coherence principle, the pressure and intensity distribution of the array at full power level can be calculated from corresponding values from the groups. With this method, computer simulations and sound field measurement of a 65-element concentric distributed phased array was carried out. The simulation results demonstrate theoretically the feasibility of this method. Measurements on the 65-element phased array also verify the effectiveness of this method for estimating the pressure and intensity distribution of phased array at full power level using a needle hydrophone.

  10. A Simple Method for Measuring the Verticality of Small-Diameter Driven Wells

    DEFF Research Database (Denmark)

    Kjeldsen, Peter; Skov, Bent

    1994-01-01

    The presence of stones, solid waste, and other obstructions can deflect small-diameter driven wells during installation, leading to deviations of the well from its intended position. This could lead to erroneous results, especially for measurements of ground water levels by water level meters....... A simple method was developed to measure deviations from the intended positions of well screens and determine correction factors required for proper measurement of ground water levels in nonvertical wells. The method is based upon measurement of the hydrostatic pressure in the bottom of a water column...... ground water flow directions....

  11. Measurement of carotid bifurcation pressure gradients using the Bernoulli principle.

    Science.gov (United States)

    Illig, K A; Ouriel, K; DeWeese, J A; Holen, J; Green, R M

    1996-04-01

    Current randomized prospective studies suggest that the degree of carotid stenosis is a critical element in deciding whether surgical or medical treatment is appropriate. Of potential interest is the actual pressure drop caused by the blockage, but no direct non-invasive means of quantifying the hemodynamic consequences of carotid artery stenoses currently exists. The present prospective study examined whether preoperative pulsed-Doppler duplex ultrasonographic velocity (v) measurements could be used to predict pressure gradients (delta P) caused by carotid artery stenoses, and whether such measurements could be used to predict angiographic percent diameter reduction. Preoperative Doppler velocity and intraoperative direct pressure measurements were obtained, and per cent diameter angiographic stenosis measured in 76 consecutive patients who underwent 77 elective carotid endarterectomies. Using the Bernoulli principle (delta P = 4v(2), pressure gradients across the stenoses were calculated. The predicted delta P, as well as absolute velocities and internal carotid artery/common carotid velocity ratios were compared with the actual delta P measured intraoperatively and with preoperative angiography and oculopneumoplethysmography (OPG) results. An end-diastolic velocity of > or = 1 m/s and an end-diastolic internal carotid artery/common carotid artery velocity ratio of > or = 10 predicted a 50% diameter angiographic stenosis with 100% specificity. Although statistical significance was reached, preoperative pressure gradients derived from the Bernoulli equation could not predict actual individual intraoperative pressure gradients with enough accuracy to allow decision making on an individual basis. Velocity measurements were as specific and more sensitive than OPG results. Delta P as predicted by the Bernoulli equation is not sufficiently accurate at the carotid bifurcation to be useful for clinical decision making on an individual basis. However, end

  12. Criticism on Jäntti's Three Point Method on curtailing gas adsorption measurements

    NARCIS (Netherlands)

    Massen, C.H.; Poulis, J.A.; Robens, E.

    2000-01-01

    Jäntti introduced a method to reduce the time required for the stepwise measurement of adsorption isotherms (Jäntti et al., Progress in Vacuum Microbalance Techniques, Vol. 1, Heyden, London, pp. 345–353, 1972). After a pressure change he measured the adsorbed mass three times and calculated its

  13. Blood pressure measurement in epidemiological investigations in teenagers

    International Nuclear Information System (INIS)

    Coppieters, Yves; Parent, Florence; Berghmans, Luc; Godin, Isabelle; Leveque, Alain

    2001-01-01

    Background: The use of sphygmomanometers may lead to problems in investigations on health of young people. The purpose of this paper is to present the validation of the blood pressure (BP) collected during the survey 'Youth Heart Health' in Hainaut by using second sample of young people in Hainaut for which BP was measured by a manual taking of tension and by an electronic device. Methods: Validation was done with a control sample of 343 young with five successive BP measures: twice with the mercury sphygmomanometer and three with DXL. We compared the manual and the electronic measures in order to study the correlation between the two methods. The control sample was used in order to compare the BP measurements with the results of the survey on the health of young people in Hainaut. Results: The differences between manual systolic BP and Dinamap measures are significant (differences in averages 3.6 mmHg; d.s. 7.8; 95% CI: 2.8-4.4 mmHg; p < 0.001) and the regression coefficient is -0.015. Diastolic BP is significantly higher with the manual method than with Dinamap (differences in means: 8.2 mmHg; d.s. 7.0; 95% CI: 7.4-8.9 mmHg; p < 0.001) and the coefficient of regression is 0.096. We observe a difference in BP between the general survey and the control group (10.3 mmHg for systolic manual control and of 10.9 mmHg for systolic electronic control; 3.3 mmHg for diastolic manual control and of 11.5 mmHg for diastolic electronic control). Conclusions: The values of BP of the 'Youth Heart Health' are significantly higher. These observations indicate the difficulties in the choice of the tool for measurements of BP in epidemiological investigations in the teenagers. In order to decrease skews of observations in the measurement of BP, it is recommended to use a valid electronic instrument. Dinamap XL is an instrument of choice in such studies of young people. Environmental and organisational factors may also explain the observed difference, which means that survey

  14. Calibration of the pressure sensitivity of microphones by a free-field method at frequencies up to 80 khz.

    Science.gov (United States)

    Zuckerwar, Allan J; Herring, G C; Elbing, Brian R

    2006-01-01

    A free-field (FF) substitution method for calibrating the pressure sensitivity of microphones at frequencies up to 80 kHz is demonstrated with both grazing and normal-incidence geometries. The substitution-based method, as opposed to a simultaneous method, avoids problems associated with the nonuniformity of the sound field and, as applied here, uses a 1/4-in. air-condenser pressure microphone as a known reference. Best results were obtained with a centrifugal fan, which is used as a random, broadband sound source. A broadband source minimizes reflection-related interferences that can plague FF measurements. Calibrations were performed on 1/4-in. FF air-condenser, electret, and microelectromechanical systems (MEMS) microphones in an anechoic chamber. The uncertainty of this FF method is estimated by comparing the pressure sensitivity of an air-condenser FF microphone, as derived from the FF measurement, with that of an electrostatic actuator calibration. The root-mean-square difference is found to be +/- 0.3 dB over the range 1-80 kHz, and the combined standard uncertainty of the FF method, including other significant contributions, is +/- 0.41 dB.

  15. Development of a pressure based vortex-shedding meter: measuring unsteady mass-flow in variable density gases

    International Nuclear Information System (INIS)

    Ford, C L; Winroth, M; Alfredsson, P H

    2016-01-01

    An entirely pressure-based vortex-shedding meter has been designed for use in practical time-dependent flows. The meter is capable of measuring mass-flow rate in variable density gases in spite of the fact that fluid temperature is not directly measured. Unlike other vortex meters, a pressure based meter is incredibly robust and may be used in industrial type flows; an environment wholly unsuitable for hot-wires for example. The meter has been tested in a number of static and dynamic flow cases, across a range of mass-flow rates and pressures. The accuracy of the meter is typically better than about 3% in a static flow and resolves the fluctuating mass-flow with an accuracy that is better than or equivalent to a hot-wire method. (paper)

  16. Blood pressure measurement of all five fingers by strain gauge plethysmography

    DEFF Research Database (Denmark)

    Hirai, M; Nielsen, S L; Lassen, N A

    1976-01-01

    of the other fingers was measured using a 24-mm-wide cuff. Blood pressure at the proximal phalanx was higher than that at the intermediate phalanx in all fingers except finger V. The difference of blood pressure values corresponded well with circumference of the finger. In 15 normal subjects, blood pressure...... at the proximal phalanx was compared in fingers I, III, IV, and V, using 16, 20, 24 and 24 mm wide cuffs. Finger blood pressure was closest to arm systolic blood pressure when a 24-mm or 27-mm-wide cuff was used in fingers I, III, and IV, and with a 20-mm-wide cuff in finger V. As the standard deviation......The aim of the present paper was to study the methodological problems involved in measuring systolic blood pressure in all five fingers by the strain gauge technique. In 24 normal subjects, blood pressure at the proximal phalanx of finger I and both at the proximal and the intermediate phalanx...

  17. Soot particle size measurements in ethylene diffusion flames at elevated pressures

    KAUST Repository

    Steinmetz, Scott

    2016-05-07

    Soot particle size is investigated in laminar nitrogen-diluted ethylene coflow diffusion flames at 4, 8, 12 and 16 atm. Line of sight attenuation and scattering are used to measure two-dimensional soot volume fraction and particle size fields for the first time at elevated pressures. Soot volume fraction dependence on pressure is consistent with the observations of similar studies, scaling approximately with the square of pressure. Scattering intensity is analyzed through Rayleigh and Rayleigh-Debye-Gans polydisperse fractal aggregate theories to provide two estimates of particle size. An increase in overall particle sizes with pressure is found, consistent with similar one-dimensional studies. Particle diameters in the annulus of the flame increase faster with pressure than those on centerline. Contrary to previous studies, the dependence of particle size on pressure was found to taper off between 8 and 12 atm, with little observed growth beyond 12 atm. The measurements provide additional data for one of the International Sooting Flame (ISF) workshop\\'s target pressurized flames.

  18. Measuring infrared contributions to the QCD pressure

    CERN Document Server

    Kajantie, Keijo; Rummukainen, K; Schröder, Y

    2002-01-01

    For the pressure (or free energy) of QCD, four-dimensional (4d) lattice data is available at zero baryon density up to a few times the critical temperature $T_c$. Perturbation theory, on the other hand, has serious convergence problems even at very high temperatures. In a combined analytical and three-dimensional (3d) lattice method, we show that it is possible to compute the QCD pressure from about $2 T_c$ to infinity. The numerical accuracy is good enough to resolve in principle, e.g., logarithmic contributions related to 4-loop perturbation theory.

  19. Measurement and analysis of pressure tube elongation in the Douglas Point reactor

    International Nuclear Information System (INIS)

    Causey, A.R.; MacEwan, S.R.; Jamieson, H.C.; Mitchell, A.B.

    1980-02-01

    Elongations of zirconium alloy pressure tubes in CANDU reactors, which occur as a result of neutron-irradiation-induced creep and growth, have been measured over the past 6 years, and the consequences of thses elongations have recently been analysed. Elongation rates, previously deduced from extensive measurements of elongations of cold-worked Zircaloy-2 pressure tubes in the Pickering reactors, have been modified to apply to the pressure tubes in the Douglas Point (DP) reactor by taking into account measured diffences in texture and dislocation density. Using these elongation rates, and structural data unique to the DP reactor, the analysis predicts elongation behaviour which is in good agreement with pressure tube elongations measured during the ten years of reactor operation. (Auth)

  20. Differences in blood pressure measurements in the forearm and upper arm of obese otherwise healthy first year medical students

    Directory of Open Access Journals (Sweden)

    Suganthi V, Navin Rajaratnam, Suzanne Maria D’cruz

    2014-07-01

    Full Text Available Background: The prevalence of obesity is increasing in Indian youth and obesity is associated with complications like systemic hypertension. Often, due to the non-availability of appropriate sized cuffs, standard cuff bladders are used to measure blood pressure in the forearms of obese young adults. Aim: To compare the upper arm arterial blood pressure measured using an appropriate cuff with the forearm arterial blood pressure measured using a standard cuff and conventional sphygmomanometry in obese otherwise healthy first year medical students. Materials and Methods: Blood pressure was measured in 27 obese otherwise healthy first year medical students after five minutes of rest using a mercury sphygmomanometer with the subjects seated and the arm and forearm at heart level, using an appropriate sized cuff for the upper arm according to American Heart Association standards and a standard cuff for the fore arm. Results: A statistically significant difference in both systolic [t-test (paired = -6.921; df = 26; sig = .000 (2- tailed] and diastolic blood pressure [t-test (paired = -8.508; df = 26; sig = .000 (2- tailed] was found, with the blood pressure readings being higher in the forearm. The correlations between upper arm and forearm systolic and diastolic blood pressure were 0.785 (p = .000 and 0.870 (p = .000. Conclusion: Both systolic and diastolic blood pressure measurements were significantly higher in the forearm. Further studies with larger sample size should be conducted to confirm that forearm blood pressure measurements using standard cuff bladders cannot be considered equal to upper arm measurements made using an appropriate sized cuff in all young obese individuals

  1. Relevance to Home Blood Pressure Monitoring Protocol of Blood Pressure Measurements Taken Before First- Morning Micturition and in the Afternoon

    Directory of Open Access Journals (Sweden)

    Antonio Eduardo Monteiro de Almeida

    2014-10-01

    Full Text Available Background: The importance of measuring blood pressure before morning micturition and in the afternoon, while working, is yet to be established in relation to the accuracy of home blood pressure monitoring (HBPM. Objective: To compare two HBPM protocols, considering 24-hour ambulatory blood pressure monitoring (wakefulness ABPM as gold-standard and measurements taken before morning micturition (BM and in the afternoon (AM, for the best diagnosis of systemic arterial hypertension (SAH, and their association with prognostic markers. Methods: After undergoing 24-hour wakefulness ABPM, 158 participants (84 women were randomized for 3- or 5-day HBPM. Two variations of the 3-day protocol were considered: with measurements taken before morning micturition and in the afternoon (BM+AM; and with post-morning-micturition and evening measurements (PM+EM. All patients underwent echocardiography (for left ventricular hypertrophy - LVH and urinary albumin measurement (for microalbuminuria - MAU. Result: Kappa statistic for the diagnosis of SAH between wakefulness-ABPM and standard 3-day HBPM, 3-day HBPM (BM+AM and (PM+EM, and 5-day HBPM were 0.660, 0.638, 0.348 and 0.387, respectively. The values of sensitivity of (BM+AM versus (PM+EM were 82.6% × 71%, respectively, and of specificity, 84.8% × 74%, respectively. The positive and negative predictive values were 69.1% × 40% and 92.2% × 91.2%, respectively. The comparisons of intraclass correlations for the diagnosis of LVH and MAU between (BM+AM and (PM+EM were 0.782 × 0.474 and 0.511 × 0.276, respectively. Conclusions: The 3 day-HBPM protocol including measurements taken before morning micturition and during work in the afternoon showed the best agreement with SAH diagnosis and the best association with prognostic markers.

  2. Method of detecting construction faults in concrete pressure vessels

    International Nuclear Information System (INIS)

    Robertson, S.A.; Duhoux, M.; Dawance, G.; Carrie, C.; Morel, D.

    1976-01-01

    A major problem in the design and construction of concrete pressure vessels for nuclear power stations is the risk of excessive air leaks through the concrete itself, due to faulty construction. The 'sonic coring' method of non-destructive concrete testing has been used successfully in pile and diaphragm wall construction control for several years, and the potential use of this method to control the presence of faults in concrete pressure vessels is here described. (author)

  3. Measurements of Pfirsch-Schlueter current and pressure profile for the high density ECH plasmas in Heliotron DR

    International Nuclear Information System (INIS)

    Morimoto, S.; Yanagi, N.; Nakasuga, M.; Obiki, T.; Iiyoshi, A.; Uo, K.

    1988-01-01

    The Pfirsch-Schlueter current and pressure profiles are estimated from magnetic measurements for high density electron cyclotron heating (ECH) plasmas (n-bar e =(2-3)x10 13 cm -3 , T e0 =200-400 eV, (β) 0 (1-(r/a) 2 ) s , is about two in macroscopically stable plasmas. A fast loss of plasma energy from the centre to the periphery is observed during the onset of the MHD instability. This method of measuring the pressure profile shape is simple and useful for heliotron type devices. (author). 20 refs, 8 figs, 1 tab

  4. Influence of Post-treatment Methods on Pressure Change of Filter Bag

    Directory of Open Access Journals (Sweden)

    Yihua Yin

    2016-01-01

    Full Text Available The PPS needle-punched non-woven filters with different post-treatments were studied by filter testing system. The pressure drop was measured at various filtration velocity, dust deposition time and the temperature during the experiment; and the effect of dust-cleaning as the consequence of pressure of filter bag was measured. The results showed that post-treatments transformed the surfaces of filters, and the dust formation differed greatly. Excessively high filtration velocity decreased the peak pressure in the process of dust-cleaning. The pressure of filter bag was increased as the dust layers were thickened. The higher temperature in filtration rose the peak pressure of filter bag, but decreased the rate of rising.

  5. Inverse method for stress monitoring in pressure components of steam generators

    International Nuclear Information System (INIS)

    Duda, P.

    2003-01-01

    The purpose of this work is to formulate a space marching method, which can be used to solve inverse multidimensional heat conduction problems. The method is designed to reconstruct the transient temperature distribution in a whole construction element based on measured temperatures taken at selected points inside or on the outer surface of the construction element. Next, the Finite Element Method is used to calculate thermal stresses and stresses caused by other loads such as, for instance, internal pressure. The developed method for solving temperature and total stress distribution will be tested using the measured temperatures generated from a direct solution. Transient temperature and total stress distribution obtained from method presented below will be compared with the values obtained from the direct solution. Finally, the presented method will be applied in order to monitor temperature and stress distribution in an outlet header using the real measured temperature values at seven points on the header's outer surface during the power boiler's shut down operation. The presented method allows to optimize the power block's start-up and shut-down operations, contributes to the reduction of heat loss during these operations and to the extension of power block's life. The fatigue and creep usage factor can be computed in an on-line mode. The presented method herein can be applied to monitoring systems that work in conventional as well as in nuclear power plants. (author)

  6. Primary flow meter for calibrating a sniffer test leak artefact by a pressure rise method

    Science.gov (United States)

    Arai, Kenta; Yoshida, Hajime

    2014-10-01

    Sniffer tests are used to locate leaks in equipment during operation. The sensitivity of a sniffer leak detector must be calibrated against a known gas flow to atmospheric pressure generated by a sniffer test leak artefact. We have developed a primary flow meter for calibrating gas flows to atmospheric pressure through the leak artefact. The flow meter is based on a pressure rise method and two chambers are used to measure the pressure rise with small uncertainty even at atmospheric pressure. The calibration range of the flow rate is 5 × 10-7 Pa m3 s-1 to 7 × 10-4 Pa m3 s-1 to atmospheric pressure at 23.0 °C with a minimum uncertainty of 1.4% (k = 2), as well as 4 × 10-8 Pa m3 s-1 to 5 × 10-4 Pa m3 s-1 to a vacuum at 23.0 °C. The long term stability of the flow meter was determined as 0.41% by repeated measurements of the conductance of the leak artefact. In case of the flow rate into a vacuum, the flow meter was successfully linked to the international reference value of CCM.P-K12 by a lab-internal comparison.

  7. Comparison of different screening methods for blood pressure disorders in children and adolescents.

    Science.gov (United States)

    Mourato, Felipe Alves; Lima Filho, José Luiz; Mattos, Sandra da Silva

    2015-01-01

    To compare different methods of screening for blood pressure disorders in children and adolescents. A database with 17,083 medical records of patients from a pediatric cardiology clinic was used. After analyzing the inclusion and exclusion criteria, 5,650 were selected. These were divided into two age groups: between 5 and 13 years and between 13 and 18 years. The blood pressure measurement was classified as normal, pre-hypertensive, or hypertensive, consistent with recent guidelines and the selected screening methods. Sensitivity, specificity, and accuracy were then calculated according to gender and age range. The formulas proposed by Somu and Ardissino's table showed low sensitivity in identifying pre-hypertension in all age groups, whereas the table proposed by Kaelber showed the best results. The ratio between blood pressure and height showed low specificity in the younger age group, but showed good performance in adolescents. Screening tools used for the assessment of blood pressure disorders in children and adolescents may be useful to decrease the current rate of underdiagnosis of this condition. The table proposed by Kaelber showed the best results; however, the ratio between BP and height demonstrated specific advantages, as it does not require tables. Copyright © 2014 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  8. Heat-washout measurements compared to distal blood pressure and perfusion in orthopaedic patients with foot ulcers

    DEFF Research Database (Denmark)

    Midttun, M; Azad, B B S; Broholm, R

    2015-01-01

    Distal blood pressure and local skin perfusion pressure were compared to measurement of blood flow rate (BFR) measured by the heat-washout method in orthopaedic patients with and without diabetes, all with a foot ulcer in one foot, compared to healthy controls. The correlation was good between heat......-washout and distal blood pressure in patients with diabetes with and without an ulcer (P = 0·024 and 0·059, respectively). The correlation was weak in patients without diabetes with and without an ulcer, most probably due to power problems (P = 0·118 and 0·116, respectively). The correlation in the healthy controls...... the surrounding tissue, and therefore, measurements are easier made in these subjects. BFR in the first toe increased significantly in all patients when the foot was moved from heart level to 50 cm below heart level (P = between 0·03 and 0·05) as previously seen in patients with claudication...

  9. Intraocular pressure measurement: Goldmann Applanation Tonometer vs non contact airpuff tonometer.

    Science.gov (United States)

    Shah, Masood Alam; Bin Saleem, Khalid; Mehmood, Talat

    2012-01-01

    An accurate assessment of Intraocular pressure (IOP) is vital in establishing diagnosis of Glaucoma and decision making regarding various treatment modalities available. The purpose of this study is to compare Goldmann Applanation Tonometer (GAT) with Air puff tonometer. Cross-sectional comparative study conducted. 73 eyes from 73 patients were included in this study and intraocular pressure (IOP) was measured by GAT and PT100 at Sheikh Khalifa Bin Zayed Hospital, Muzaffarabad, Benazir Shaheed Teaching Hospital, Abbottabad. Mean age of the patients was 53.17 +/- 13.80 years. Mean IOP measurements showed significant differences in measurements performed by the two tonometers (p contact air-puff tonometer, the Goldmann applanation tonometer is a reliable and consistent technique for measurement of intraocular pressure.

  10. Acoustic emission measurements at the pressure vessel ZB2

    International Nuclear Information System (INIS)

    Tirbonod, B.; Hanacek, L.

    1990-01-01

    The work presented here is the Swiss contribution to the project 'Zwischenbehaelter 2 (ZB2)' hosted by the 'Bundesministerium fuer Forschung und Technologie' of the Federal Republic of Germany. One of the crack-like defects introduced at the inside surface of the thick-walled pressure vessel ZB2 was locally monitored by acoustic emission. The measurement system was broadband (0.5 - 5 MHz) and allowed a threedimensional location of the source. The vessel was subjected to different tests. Signals were recorded during the second series of hydrotests, fast pressure cycles and fatigue test at 50 C. About 1 signal per hydrotest or cycle was recorded. For the hydrotests the signals were recorded generally at loading in the intermediate range of pressure; the sources were located in the artificial defect. Recurrent and non recurrent signals were recorded during the fatigue test. At loading, signals were captured up to the maximum pressure and for the recurrent signals at well defined pressure ranges. All the sources (except one, located in the base material ahead of the artificial defect) were situated in the artificial defect. The pressure and location depended on the loading phase and on the cycle range. The measurements were discussed by describing the signals by measurement, signal and source parameters. The goal was to identify the source mechanism and to assess the growth of the defect. For the hydrotests the identification of the mechanism at loading remains open. For the fatigue test the source situated in the base material was attributed to a primary mechanism; this source could assess the growth of the defect on the basis of linear elastic fracture mechanics. A secondary mechanism was suggested for recurrent sources active at loading. For all the tests, the sources active at unloading were attributed to a secondary mechanism. (author)

  11. Reliable intraocular pressure measurement using automated radio-wave telemetry

    Directory of Open Access Journals (Sweden)

    Paschalis EI

    2014-01-01

    Full Text Available Eleftherios I Paschalis,* Fabiano Cade,* Samir Melki, Louis R Pasquale, Claes H Dohlman, Joseph B CiolinoMassachusetts Eye and Ear Infirmary, Harvard Medical School, Boston, MA, USA*These authors contributed equally to this workPurpose: To present an autonomous intraocular pressure (IOP measurement technique using a wireless implantable transducer (WIT and a motion sensor.Methods: The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline IOP.Results: On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg and mean vehicle IOP (13.27±2.1 mmHg (P=0.45, suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001, and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001. Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001. Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute, during which the IOP is not expected to change.Conclusion: IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results.Keywords: IOP, pressure transducer, wireless, MEMS, implant, intraocular

  12. Comparison of exercise blood pressure measured by technician and an automated system.

    Science.gov (United States)

    Garcia-Gregory, J A; Jackson, A S; Studeville, J; Squires, W G; Owen, C A

    1984-05-01

    We evaluated the automated system Blood Pressure Measuring System (BPMS) developed by NASA on 277 adult males who elected to have a treadmill test as part of their annual physical. The BPMS uses acoustic transduction with a computer-assisted ECG gating to detect nonsynchronous noise. The BPMS readings were compared to pressures simultaneously measured by trained technicians. For all stages of work, BPMS readings were higher for systolic and lower for diastolic than technician readings. At peak stages of work, BPMS systolic pressures were about 20 mmHg higher than technician readings. Within each 3-min workstage, BPMS readings were found to be more inconsistent than technician readings. The standard errors of measurement for BPMS were from two to three times higher than technician values. These data showed automated blood pressure readings were significantly different than technician values and subject to more random fluctuations. These findings demonstrate the need to view exercise blood pressure measured by automated systems with caution.

  13. Prospective Study on Noninvasive Assessment of Intracranial Pressure in Traumatic Brain-Injured Patients: Comparison of Four Methods.

    Science.gov (United States)

    Cardim, Danilo; Robba, Chiara; Donnelly, Joseph; Bohdanowicz, Michal; Schmidt, Bernhard; Damian, Maxwell; Varsos, Georgios V; Liu, Xiuyun; Cabeleira, Manuel; Frigieri, Gustavo; Cabella, Brenno; Smielewski, Peter; Mascarenhas, Sergio; Czosnyka, Marek

    2016-04-15

    Elevation of intracranial pressure (ICP) may occur in many diseases, and therefore the ability to measure it noninvasively would be useful. Flow velocity signals from transcranial Doppler (TCD) have been used to estimate ICP; however, the relative accuracy of these methods is unclear. This study aimed to compare four previously described TCD-based methods with directly measured ICP in a prospective cohort of traumatic brain-injured patients. Noninvasive ICP (nICP) was obtained using the following methods: 1) a mathematical "black-box" model based on interaction between TCD and arterial blood pressure (nICP_BB); 2) based on diastolic flow velocity (nICP_FVd); 3) based on critical closing pressure (nICP_CrCP); and 4) based on TCD-derived pulsatility index (nICP_PI). In time domain, for recordings including spontaneous changes in ICP greater than 7 mm Hg, nICP_PI showed the best correlation with measured ICP (R = 0.61). Considering every TCD recording as an independent event, nICP_BB generally showed to be the best estimator of measured ICP (R = 0.39; p area under the curve [AUC] = 0.66; p AUC (0.70; p AUC = 0.64; p > 0.05). nICP_PI was not related to measured ICP using any of the above statistical indicators. We also introduced a new estimator (nICP_Av) based on the average of three methods (nICP_BB, nICP_FVd, and nICP_CrCP), which overall presented improved statistical indicators (R = 0.47; p AUC = 0.73; p < 0.05). nICP_PI appeared to reflect changes in ICP in time most accurately. nICP_BB was the best estimator for ICP "as a number." nICP_Av demonstrated to improve the accuracy of measured ICP estimation.

  14. Multi-spectral temperature measurement method for gas turbine blade

    Science.gov (United States)

    Gao, Shan; Feng, Chi; Wang, Lixin; Li, Dong

    2016-02-01

    One of the basic methods to improve both the thermal efficiency and power output of a gas turbine is to increase the firing temperature. However, gas turbine blades are easily damaged in harsh high-temperature and high-pressure environments. Therefore, ensuring that the blade temperature remains within the design limits is very important. There are unsolved problems in blade temperature measurement, relating to the emissivity of the blade surface, influences of the combustion gases, and reflections of radiant energy from the surroundings. In this study, the emissivity of blade surfaces has been measured, with errors reduced by a fitting method, influences of the combustion gases have been calculated for different operational conditions, and a reflection model has been built. An iterative computing method is proposed for calculating blade temperatures, and the experimental results show that this method has high precision.

  15. Propagation of Radiosonde Pressure Sensor Errors to Ozonesonde Measurements

    Science.gov (United States)

    Stauffer, R. M.; Morris, G.A.; Thompson, A. M.; Joseph, E.; Coetzee, G. J. R.; Nalli, N. R.

    2014-01-01

    Several previous studies highlight pressure (or equivalently, pressure altitude) discrepancies between the radiosonde pressure sensor and that derived from a GPS flown with the radiosonde. The offsets vary during the ascent both in absolute and percent pressure differences. To investigate this problem further, a total of 731 radiosonde-ozonesonde launches from the Southern Hemisphere subtropics to Northern mid-latitudes are considered, with launches between 2005 - 2013 from both longer-term and campaign-based intensive stations. Five series of radiosondes from two manufacturers (International Met Systems: iMet, iMet-P, iMet-S, and Vaisala: RS80-15N and RS92-SGP) are analyzed to determine the magnitude of the pressure offset. Additionally, electrochemical concentration cell (ECC) ozonesondes from three manufacturers (Science Pump Corporation; SPC and ENSCI-Droplet Measurement Technologies; DMT) are analyzed to quantify the effects these offsets have on the calculation of ECC ozone (O3) mixing ratio profiles (O3MR) from the ozonesonde-measured partial pressure. Approximately half of all offsets are 0.6 hPa in the free troposphere, with nearly a third 1.0 hPa at 26 km, where the 1.0 hPa error represents 5 persent of the total atmospheric pressure. Pressure offsets have negligible effects on O3MR below 20 km (96 percent of launches lie within 5 percent O3MR error at 20 km). Ozone mixing ratio errors above 10 hPa (30 km), can approach greater than 10 percent ( 25 percent of launches that reach 30 km exceed this threshold). These errors cause disagreement between the integrated ozonesonde-only column O3 from the GPS and radiosonde pressure profile by an average of +6.5 DU. Comparisons of total column O3 between the GPS and radiosonde pressure profiles yield average differences of +1.1 DU when the O3 is integrated to burst with addition of the McPeters and Labow (2012) above-burst O3 column climatology. Total column differences are reduced to an average of -0.5 DU when

  16. Gravimetric capillary method for kinematic viscosity measurements

    Science.gov (United States)

    Rosenberger, Franz; Iwan, J.; Alexander, D.; Jin, Wei-Qing

    1992-01-01

    A novel version of the capillary method for viscosity measurements of liquids is presented. Viscosity data can be deduced in a straightforward way from mass transfer data obtained by differential weighing during the gravity-induced flow of the liquid between two cylindrical chambers. Tests of this technique with water, carbon tetrachloride, and ethanol suggest that this arrangement provides an accuracy of about +/- 1 percent. The technique facilitates operation under sealed, isothermal conditions and, thus can readily be applied to reactive and/or high vapor pressure liquids.

  17. Gain measurements in CO2 CW low pressure lasers

    International Nuclear Information System (INIS)

    Rodrigues, N.A.S.; Chanes Junior, J.B.; Jayaram, K.

    1983-01-01

    A series of gain measurements in low pressure CO 2 CW laser were performed in order to study the behaviour of a CO 2 laser ampliflier as a function of pressure and discharge current. A theoretical model, based on rate equations is also presented to describe the laser behaviour and the experimental procedure adopted. (C.L.B.) [pt

  18. A study of mechanical sealing methods using graphite powder for high pressure vessel

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, H. Y.; Hong, J. T.; Ahn, S. H.; Joung, C. Y. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-10-15

    The Fuel Test Loop (FTL) is a facility that can conduct fuel irradiation tests at the HANARO (High flux Advanced Neutron Application Reactor). The FTL simulates commercial NPP operating conditions such as pressure, temperature and neutron flux levels to conduct irradiation and thermo hydraulic tests. It is composed of an In Pile test Section (IPS) and an Out Pile System (OPS). The OPS contains a pressurizer, cooler, pump, heater and purification system, which are necessary to maintain the proper fluid conditions. In addition, the OPS contains engineered safety systems that can safely shutdown both HANARO and FTL if an accident occurs. The IPS accommodating fuel pins has a loaded IP 1 hole in HANARO, and a double pressure vessel for the design conditions of 350 .deg. C, 17.5MPa and is composed of an outer assembly and inner assembly. It has instruments such as a thermocouple, LVDT and SPND to measure the fuel performances during the test. FTL coolant is supplied to the IPS at the core of commercial nuclear power plants at the same temperature, pressure and flow conditions. Sensors are installed on the inside of the IPS to send signal transmission MI Cables to the outside for instrumentation through the pressure boundary. Therefore, the pressure boundary should be maintained in the sealing performance. Currently, the sealing of the IPS of the the FTL is maintained through a brazing method. However, A brazing method has disadvantages that can occur owing to thermal deformation or breakage in the instrumentation Mi cable. IPS inner assembly is a very long design length (approximately 5.29m), so it is difficult to perform in a vacuum chamber. Therefore, an easy and reliable way to assemble the instrumentation Mi cable mechanical sealing method has been studied. In this study, criteria tests at the pressure boundary were performed using universally applicable graphite powder for the instrumentation MI cable of various sizes.

  19. A study of mechanical sealing methods using graphite powder for high pressure vessel

    International Nuclear Information System (INIS)

    Jeong, H. Y.; Hong, J. T.; Ahn, S. H.; Joung, C. Y.

    2012-01-01

    The Fuel Test Loop (FTL) is a facility that can conduct fuel irradiation tests at the HANARO (High flux Advanced Neutron Application Reactor). The FTL simulates commercial NPP operating conditions such as pressure, temperature and neutron flux levels to conduct irradiation and thermo hydraulic tests. It is composed of an In Pile test Section (IPS) and an Out Pile System (OPS). The OPS contains a pressurizer, cooler, pump, heater and purification system, which are necessary to maintain the proper fluid conditions. In addition, the OPS contains engineered safety systems that can safely shutdown both HANARO and FTL if an accident occurs. The IPS accommodating fuel pins has a loaded IP 1 hole in HANARO, and a double pressure vessel for the design conditions of 350 .deg. C, 17.5MPa and is composed of an outer assembly and inner assembly. It has instruments such as a thermocouple, LVDT and SPND to measure the fuel performances during the test. FTL coolant is supplied to the IPS at the core of commercial nuclear power plants at the same temperature, pressure and flow conditions. Sensors are installed on the inside of the IPS to send signal transmission MI Cables to the outside for instrumentation through the pressure boundary. Therefore, the pressure boundary should be maintained in the sealing performance. Currently, the sealing of the IPS of the the FTL is maintained through a brazing method. However, A brazing method has disadvantages that can occur owing to thermal deformation or breakage in the instrumentation Mi cable. IPS inner assembly is a very long design length (approximately 5.29m), so it is difficult to perform in a vacuum chamber. Therefore, an easy and reliable way to assemble the instrumentation Mi cable mechanical sealing method has been studied. In this study, criteria tests at the pressure boundary were performed using universally applicable graphite powder for the instrumentation MI cable of various sizes

  20. Method of extraction under pressure of fossil material

    Energy Technology Data Exchange (ETDEWEB)

    Fredenmark, G L

    1942-02-24

    A method is described of extraction under pressure of fossil material, such as coal, brown coal (lignite), peat, oil shale. It is characterized by carrying out the process of extraction by utilization of fractions of shale oils and/or peat tar with a boiling point above 170/sup 0/C and under such as pressure that the medium of extraction is in a liquid state.

  1. Oscillometric and auscultatory blood pressure measurement methods in children: a systematic review and meta-analysis.

    Science.gov (United States)

    Duncombe, Stephanie L; Voss, Christine; Harris, Kevin C

    2017-02-01

    The phase-out of mercury from clinical settings calls for valid alternatives to assess blood pressure (BP) in children. Aneroid devices provide a mercury-free alternative to BP measurements by auscultation, whereas oscillometric (automated) devices are increasingly becoming the norm in clinical practice due to their ease of use. The aim of this systematic review and meta-analysis was to investigate the accuracy of oscillometric and aneroid BP devices compared with the mercury sphygmomanometer for the measurement of BP in children. We systematically searched four electronic databases (MEDLINE, Embase, CINAHL, and Web of Science) and relevant journals for eligible articles published before 30 July 2015. We screened 1415 articles, and two authors independently reviewed 92 full-text articles. We included 29 articles (38 studies) with 26 879 children. Random-effects model meta-analyses revealed that oscillometric devices yield higher measurements of SBP than auscultation with a mercury sphygmomanometer (pooled effect estimate 2.53 mmHg; 95% CI 0.57-4.50; P devices and found comparable results. Oscillometric devices may serve as a suitable alternative to auscultation for initial BP screening in the pediatric population.

  2. The identification and repair of anomalous measurements in the measurement of big diameter based on rolling-wheel method

    Science.gov (United States)

    Chen, Haiou; Yu, Xiaofen

    2011-05-01

    Rolling-wheel method is an effective way of measuring big diameter. After amending the temperature error and pressure error, the uncertainty of measurement can not be φ =5um/m stably because of the influence of skid. The traditional method of identifying skid loses sight of the influences of the unstable motor speed, the appearance form error and the eccentric of installation of the big axis and rolling wheel and so on, so the method has its limitation. In this paper, a new method of multiple identification and repair is introduced, namely n diameters are measured and Chauvenet standard is used for identifying the anomalous measurements one by one, and then the average value of the remaining data is used for repairing identified anomalous measurements, and the next round identification and repair is carried out until the accuracy requirement of the measurement is satisfied. The result of experiments indicates that the method can identify anomalous measurements whose offsets caused by the skid are greater than 0.2φ , and the uncertainty of measurement has improved substantially.

  3. Magneto-structural transformations via a solid-state nudged elastic band method: Application to iron under pressure

    International Nuclear Information System (INIS)

    Zarkevich, N. A.; Johnson, D. D.

    2015-01-01

    We extend the solid-state nudged elastic band method to handle a non-conserved order parameter, in particular, magnetization, that couples to volume and leads to many observed effects in magnetic systems. We apply this formalism to the well-studied magneto-volume collapse during the pressure-induced transformation in iron—from ferromagnetic body-centered cubic (bcc) austenite to hexagonal close-packed (hcp) martensite. We find a bcc-hcp equilibrium coexistence pressure of 8.4 GPa, with the transition-state enthalpy of 156 meV/Fe at this pressure. A discontinuity in magnetization and coherent stress occurs at the transition state, which has a form of a cusp on the potential-energy surface (yet all the atomic and cell degrees of freedom are continuous); the calculated pressure jump of 25 GPa is related to the observed 25 GPa spread in measured coexistence pressures arising from martensitic and coherency stresses in samples. Our results agree with experiments, but necessarily differ from those arising from drag and restricted parametrization methods having improperly constrained or uncontrolled degrees of freedom

  4. A direct method for determining complete positive and negative capillary pressure curves for reservoir rock using the centrifuge

    Energy Technology Data Exchange (ETDEWEB)

    Spinler, E.A.; Baldwin, B.A. [Phillips Petroleum Co., Bartlesville, OK (United States)

    1997-08-01

    A method is being developed for direct experimental determination of capillary pressure curves from saturation distributions produced during centrifuging fluids in a rock plug. A free water level is positioned along the length of the plugs to enable simultaneous determination of both positive and negative capillary pressures. Octadecane as the oil phase is solidified by temperature reduction while centrifuging to prevent fluid redistribution upon removal from the centrifuge. The water saturation is then measured via magnetic resonance imaging. The saturation profile within the plug and the calculation of pressures for each point of the saturation profile allows for a complete capillary pressure curve to be determined from one experiment. Centrifuging under oil with a free water level into a 100 percent water saturated plug results in the development of a primary drainage capillary pressure curve. Centrifuging similarly at an initial water saturation in the plug results in the development of an imbibition capillary pressure curve. Examples of these measurements are presented for Berea sandstone and chalk rocks.

  5. Why use Finapres or Portapres rather than intra-arterial or intermittent non-invasive techniques of blood pressure measurement?

    NARCIS (Netherlands)

    Langewouters, G. J.; Settels, J. J.; Roelandt, R.; Wesseling, K. H.

    1998-01-01

    In the clinic, blood pressure is measured almost exclusively using non-invasive intermittent techniques, of which the auscultatory (Riva-Rocci/Korotkoff, RRK) and the computerized oscillometric method are most often used. However, both methods only provide a momentary value. In addition, the

  6. Determination of total carbonates in soil archaeometry using a new pressure method with temperature compensation

    Science.gov (United States)

    Barouchas, Pantelis; Koulos, Vasilios; Melfos, Vasilios

    2017-04-01

    For the determination of total carbonates in soil archaeometry a new technique was applied using a multi-sensor philosophy, which combines simultaneous measurement of pressure and temperature. This technology is innovative and complies with EN ISO 10693:2013, ASTM D4373-02(2007) and Soil Science Society of America standard test methods for calcium carbonate content in soils and sediments. The total carbonates analysis is based on a pressure method that utilizes the FOGII Digital Soil CalcimeterTM, which is a portable apparatus. The total carbonate content determined by treating a 1.000 g (+/- 0.001 g) dried sample specimens with 6N hydrochloric acid (HCL) reagent grade, in an enclosed reaction vessel. Carbon dioxide gas evolved during the reaction between the acid and carbonate fraction of the specimen, was measured by the resulting pressure generated, taking in account the temperature conditions during the reaction. Prior to analysis the procedure was validated with Sand/Soil mixtures from BIPEA proficiency testing program with soils of different origins. For applying this new method in archaeometry a total number of ten samples were used from various rocks which are related with cultural constructions and implements in Greece. They represent a large range of periods since the Neolithic times, and were selected because there was an uncertainty about their accurate mineralogical composition especially regarding the presence of carbonate minerals. The results were compared to the results from ELTRA CS580 inorganic carbon analyzer using an infrared cell. The determination of total carbonates for 10 samples from different ancient sites indicated a very good correlation (R2 >0.97) between the pressure method with temperature compensation and the infrared method. The proposed method is quickly and accurate in archaeometry and can replace easily other techniques for total carbonates testing. The FOGII Digital Soil CalcimeterTM is portable and easily can be carried for

  7. Intraocular pressure measurements after conductive keratoplasty.

    Science.gov (United States)

    Kymionis, George D; Naoumidi, Tatiana L; Aslanides, Ioannis M; Kumar, Vinod; Astyrakakis, Nikolaos I; Tsilimbaris, Miltiadis; Pallikaris, Ioannis G

    2005-01-01

    To determine the possible impact of conductive keratoplasty (CK) on intraocular pressure (IOP) measurements. A prospective, single-center, noncomparative interventional case series was performed. Baseline and postoperative IOPs were measured by Goldmann applanation tonometry in 32 eyes of 18 patients who underwent CK for hyperopia correction. Mean follow-up was 11.9 months (range: 8 to 18 months). After CK, a statistically significant decrease in the measured IOP was observed (before CK: 14.22+/-1.64 vs after CK: 12.66+/-2.21, P<.001). The change in IOP readings postoperatively was not correlated with age, sex, keratometric readings, or attempted correction. Despite the limitations due to the small number of patients enrolled in this study, the applanation tonometer appears to underestimate the true IOP after CK.

  8. Analysis of selected structures for model-based measuring methods using fuzzy logic

    Energy Technology Data Exchange (ETDEWEB)

    Hampel, R.; Kaestner, W.; Fenske, A.; Vandreier, B.; Schefter, S. [Hochschule fuer Technik, Wirtschaft und Sozialwesen Zittau/Goerlitz (FH), Zittau (DE). Inst. fuer Prozesstechnik, Prozessautomatisierung und Messtechnik e.V. (IPM)

    2000-07-01

    Monitoring and diagnosis of safety-related technical processes in nuclear enginering can be improved with the help of intelligent methods of signal processing such as analytical redundancies. This chapter gives an overview about combined methods in form of hybrid models using model based measuring methods (observer) and knowledge-based methods (fuzzy logic). Three variants of hybrid observers (fuzzy-supported observer, hybrid observer with variable gain and hybrid non-linear operating point observer) are explained. As a result of the combination of analytical and fuzzy-based algorithms a new quality of monitoring and diagnosis is achieved. The results will be demonstrated in summary for the example water level estimation within pressure vessels (pressurizer, steam generator, and Boiling Water Reactor) with water-steam mixture during the accidental depressurization. (orig.)

  9. Analysis of selected structures for model-based measuring methods using fuzzy logic

    International Nuclear Information System (INIS)

    Hampel, R.; Kaestner, W.; Fenske, A.; Vandreier, B.; Schefter, S.

    2000-01-01

    Monitoring and diagnosis of safety-related technical processes in nuclear engineering can be improved with the help of intelligent methods of signal processing such as analytical redundancies. This chapter gives an overview about combined methods in form of hybrid models using model based measuring methods (observer) and knowledge-based methods (fuzzy logic). Three variants of hybrid observers (fuzzy-supported observer, hybrid observer with variable gain and hybrid non-linear operating point observer) are explained. As a result of the combination of analytical and fuzzy-based algorithms a new quality of monitoring and diagnosis is achieved. The results will be demonstrated in summary for the example water level estimation within pressure vessels (pressurizer, steam generator, and Boiling Water Reactor) with water-steam mixture during the accidental depressurization. (orig.)

  10. Laser-Machined Microcavities for Simultaneous Measurement of High-Temperature and High-Pressure

    Directory of Open Access Journals (Sweden)

    Zengling Ran

    2014-08-01

    Full Text Available Laser-machined microcavities for simultaneous measurement of high-temperature and high-pressure are demonstrated. These two cascaded microcavities are an air cavity and a composite cavity including a section of fiber and an air cavity. They are both placed into a pressure chamber inside a furnace to perform simultaneous pressure and high-temperature tests. The thermal and pressure coefficients of the short air cavity are ~0.0779 nm/°C and ~1.14 nm/MPa, respectively. The thermal and pressure coefficients of the composite cavity are ~32.3 nm/°C and ~24.4 nm/MPa, respectively. The sensor could be used to separate temperature and pressure due to their different thermal and pressure coefficients. The excellent feature of such a sensor head is that it can withstand high temperatures of up to 400 °C and achieve precise measurement of high-pressure under high temperature conditions.

  11. Laser-machined microcavities for simultaneous measurement of high-temperature and high-pressure.

    Science.gov (United States)

    Ran, Zengling; Liu, Shan; Liu, Qin; Huang, Ya; Bao, Haihong; Wang, Yanjun; Luo, Shucheng; Yang, Huiqin; Rao, Yunjiang

    2014-08-07

    Laser-machined microcavities for simultaneous measurement of high-temperature and high-pressure are demonstrated. These two cascaded microcavities are an air cavity and a composite cavity including a section of fiber and an air cavity. They are both placed into a pressure chamber inside a furnace to perform simultaneous pressure and high-temperature tests. The thermal and pressure coefficients of the short air cavity are ~0.0779 nm/°C and ~1.14 nm/MPa, respectively. The thermal and pressure coefficients of the composite cavity are ~32.3 nm/°C and ~24.4 nm/MPa, respectively. The sensor could be used to separate temperature and pressure due to their different thermal and pressure coefficients. The excellent feature of such a sensor head is that it can withstand high temperatures of up to 400 °C and achieve precise measurement of high-pressure under high temperature conditions.

  12. A method of measuring the conductivity of air-sensitive substances in dependence on pressure (alkali metal anthracene addition compounds)

    International Nuclear Information System (INIS)

    Konrad Luehder, Konrad

    1996-01-01

    The conductivity of alkali anthracene addition compounds of the general formula M x (atc) with x=2.0 and = 1.5 was measured in dependence on pressure up to 400 MPa, shoving values in the range of 10 -8 S/cm. A suitable apparatus is described. (authors)

  13. Simple device to determine the pressure applied by pressure clips for the treatment of earlobe keloids

    Directory of Open Access Journals (Sweden)

    Aashish Sasidharan

    2015-01-01

    Full Text Available Background: Keloids of the ear are common problems. Various treatment modalities are available for the treatment of ear keloids. Surgical excision with intralesional steroid injection along with compression therapy has the least recurrence rate. Various types of devices are available for pressure therapy. Pressure applied by these devices is uncontrolled and is associated with the risk of pressure necrosis. We describe here a simple and easy to use device to measure pressure applied by these clips for better outcome. Objectives: To devise a simple method to measure the pressure applied by various pressure clips used in ear keloid pressure therapy. Materials and Methods: By using a force sensitive resistor (FSR, the pressure applied gets converted into voltage using electrical wires, resistors, capacitors, converter, amplifier, diode, nine-volt (9V cadmium battery and the voltage is measured using a multimeter. The measured voltage is then converted into pressure using pressure voltage graph that depicts the actual pressure applied by the pressure clip. Results: The pressure applied by different clips was variable. The spring clips were adjustable by slight variation in the design whereas the pressure applied by binder clips and magnet discs was not adjustable. Conclusion: The uncontrolled/suboptimal pressure applied by certain pressure clips can be monitored to provide optimal pressure therapy in ear keloid for better outcome.

  14. Agreement of high definition oscillometry with direct arterial blood pressure measurement at different blood pressure ranges in horses under general anaesthesia.

    Science.gov (United States)

    Tünsmeyer, Julia; Hopster, Klaus; Feige, Karsten; Kästner, Sabine Br

    2015-05-01

    To determine the agreement of high definition oscillometry (HDO) with direct arterial blood pressure measurements in normotensive, hypotensive and hypertensive horses during general anaesthesia. Experimental study. Seven healthy warmblood horses, aged 3-11 years, weighing 470-565 kg. Measurements from a HDO device with the cuff placed around the base of the tail were compared with pressures measured invasively from the facial artery. High blood pressures were induced by intravenous (IV) administration of dobutamine (5 μg kg(-1) minute(-1)) over ten minutes followed by norepinephrine (0.1 mg kg(-1) IV) and low pressures by increasing the inspired fraction of isoflurane and administration of nitroglycerine (0.05 mg kg(-1) IV). For analysis three pressure levels were determined: high (MAP>110 mmHg), normal (60 mmHgstandard deviation for SAP, MAP and DAP were 0.1 ± 19.4 mmHg, 0.5 ± 14.0, 4.7 ± 15.6, respectively. At high pressure levels bias and SD were 26.1 ± 37.3 (SAP), 4.2 ± 19.4 (MAP), 1.5 ± 16.8 (DAP) and at low pressures -20.0 ± 20.9 (SAP), -11.4 ± 19.6 (MAP), -4.7 ± 20.1 (DAP), with HDO measurements at a MAP <50 mmHg often failing. Good agreement with invasive arterial blood pressures was obtained with HDO at normotensive levels in horses. At high and low pressure ranges HDO was unreliable. Therefore, if haemodynamic instability is expected, invasive measurement remains preferable. © 2014 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

  15. Measurement for the Leak Rate enhanced by a Improved Method

    International Nuclear Information System (INIS)

    Bae, Sang-Hoon; Choi, Young-San; Kim, Young-Ki; Lee, Yong-Sub; Jung, Hoan-Sung

    2007-01-01

    The leak rate measurement of the HANARO such as a research reactor that adopts a confinement concept for a reactor hall is very important one during a period inspection. This test verifies whether the reactor building could maintain the negative pressure or not when radiation is perceived by abnormal accidents. Of course, this may not cause a problem in a reactor operation only if it can satisfy the design requirement, but it is necessary to have some margin of a limitation value because a reactor hall should be managed more conservatively than the design reference. To meet the requirements of this strict design condition, previous method was changed to a new type of test with more stable and robust measuring method. The new leak rate measurement method is briefly introduced and the merits of this proposed method are shown through the data analyzed for last 3 years

  16. [Comparative study of intraocular pressure measurements by Goldmann applanation tonometer, noncontact tonometer and TonoPen].

    Science.gov (United States)

    Ceská, Burdová M; Ferrová, K; Filous, A; Oskorypová, K; Lezatková, P; Sedlácková, P

    2012-02-01

    The purpose of the study was to compare the levels of the intraocular pressure (NOT) measured in one eye at the same moment by three different methods: by Goldmann applanation tonometer (AT), non-contact tonometer (BT) and Tono-Pen (TP). It was further set the average variability of the performed measurements for particular tonometric methods. NOT was assessed in 106 eyes of 106 subjects aged 7-77 years (average 34.3 +/- 17.1 years). NOT was measured at the same moment with BT, TP and AT. The obtained data were statistically analyzed. The average NOT was 16.55 +/- 2.95, 17.95 +/- 4.47 and 16.13 +/- 3.4 mmHg when AT, BT and TP were applied. Average variability of three measurements for AT, BT and TP was 1.51 +/- 0.96, 1.78 +/- 1.08 and 1.47 +/- 0.9 mmHg. Average NOT levels of the measured AT and TP were almost identical with a difference of 0.42 mmHg (p = 0.236). Average level of the intraocular pressure measured by BT was higher by 1.40 mmHg and 1.82 mmHg in comparison with AT and TP (p = 0.00002), respectively. NOT measurement produced almost identical average levels at AT and TP, whereas at BT the levels were much higher. Average variability of the three subsequent NOT measurements was the highest at BT, whereas at AT and TP the average variability was lower and nearly identical.

  17. Reliability and responsiveness of algometry for measuring pressure pain threshold in patients with knee osteoarthritis

    OpenAIRE

    Mutlu, Ebru Kaya; Ozdincler, Arzu Razak

    2015-01-01

    [Purpose] This study aimed to establish the intrarater reliability and responsiveness of a clinically available algometer in patients with knee osteoarthritis as well as to determine the minimum-detectable-change and standard error of measurement of testing to facilitate clinical interpretation of temporal changes. [Subjects] Seventy-three patients with knee osteoarthritis were included. [Methods] Pressure pain threshold measured by algometry was evaluated 3 times at 2-min intervals over 2 cl...

  18. Surface pressure retrieval from SCIAMACHY measurements in the O2 A Band: validation of the measurements and sensitivity on aerosols

    Directory of Open Access Journals (Sweden)

    B. van Diedenhoven

    2005-01-01

    Full Text Available We perform surface pressure retrievals from cloud-free Oxygen A band measurements of SCIAMACHY. These retrievals can be well validated because surface pressure is a quantity that is, in general, accurately known from meteorological models. Therefore, surface pressure retrievals and their validation provide important insight into the quality of the instrument calibration. Furthermore, they can provide insight into retrievals which are affected by similar radiation transport processes, for example the retrieval of total columns of H2O, CO, CO2 and CH4. In our retrieval aerosols are neglected. Using synthetic measurements, it is shown that for low to moderate surface albedos this leads to an underestimation of the retrieved surface pressures. For high surface albedos this generally leads to an overestimation of the retrieved surface pressures. The surface pressures retrieved from the SCIAMACHY measurements indeed show this dependence on surface albedo, when compared to the corresponding pressures from a meteorological database. However, an offset of about 20 hPa was found, which can not be caused by neglecting aerosols in the retrieval. The same offset was found when comparing the retrieved surface pressures to those retrieved from co-located GOME Oxygen A band measurements. This implies a calibration error in the SCIAMACHY measurements. By adding an offset of 0.86% of the continuum reflectance at 756 nm to the SCIAMACHY reflectance measurements, this systematic bias vanishes.

  19. Measured wavenumber: frequency spectrum associated with acoustic and aerodynamic wall pressure fluctuations.

    Science.gov (United States)

    Arguillat, Blandine; Ricot, Denis; Bailly, Christophe; Robert, Gilles

    2010-10-01

    Direct measurements of the wavenumber-frequency spectrum of wall pressure fluctuations beneath a turbulent plane channel flow have been performed in an anechoic wind tunnel. A rotative array has been designed that allows the measurement of a complete map, 63×63 measuring points, of cross-power spectral densities over a large area. An original post-processing has been developed to separate the acoustic and the aerodynamic exciting loadings by transforming space-frequency data into wavenumber-frequency spectra. The acoustic part has also been estimated from a simple Corcos-like model including the contribution of a diffuse sound field. The measured acoustic contribution to the surface pressure fluctuations is 5% of the measured aerodynamic surface pressure fluctuations for a velocity and boundary layer thickness relevant for automotive interior noise applications. This shows that for aerodynamically induced car interior noise, both contributions to the surface pressure fluctuations on car windows have to be taken into account.

  20. Variation of Pressure Waveforms in Measurements of Extracorporeal Shock Wave Lithotripter

    Science.gov (United States)

    Inose, Naoto; Ide, Masao

    1993-05-01

    In this paper, we describe measurement of variation in pressure waveforms of the acoustic field of an extra-corporeal shock-wave lithotripter (ESWL). Variations in the measured acoustic fields and pressure waveform of an underwater spark-gap-type ESWL with an exhausted spark plug electrode have been reported by researchers using crystal sensors. If the ESWL spark plugs become exhausted, patients feel pain during kidney, biliary stone disintegration. We studied the relationship between exhaustion of electrodes and the variation of pressure waveforms and shock-wave fields of the ESWL using a newly developed hydrophone.

  1. Flow Field Measurements of Methane-Oxygen Turbulent Nonpremixed Flames at High Pressure

    Science.gov (United States)

    Iino, Kimio; Kikkawa, Hoshitaka; Akamatsu, Fumiteru; Katsuki, Masashi

    We carried out the flow field measurement of methane-oxygen turbulent nonpremixed flame in non-combusting and combusting situations at high pressures using LDV. The main objectives are to study the influences of combustion on the turbulence structure at high pressures and to provide detailed data on which numerical predictions on such flows can rely. Direct observation and CH* chemiluminescence detection are conducted at high pressures up to 1.0MPa. It was found that the flame length at elevated pressures became constant. From flow field measurements, the following features of flames at elevated pressure were found: (1) the existence of flame suppressed turbulence in the upstream region of the jet and enhanced it in the downstream region with increasing pressure; (2) Turbulence in the flame was more anisotropic than in the corresponding cold jet in all regions of the flow with increasing pressure; (3) Reynolds shear stresses did not change at elevated pressure; (4) Combustion processes had a marked influence on the turbulence macroscale under high pressures, however, the turbulence macroscale was not changed even with the increase in pressure.

  2. Electrical probe measurements in low and high pressure discharges

    International Nuclear Information System (INIS)

    Andersson, D.

    1976-11-01

    The construction of an apparatus for automatic determination of electron distributions is described, whereafter measurements of electron energy distributions before and after a stationary plasma sheath in a low pressure mercury discharge are presented. The sheath appears at a constriction of the discharge tube. The measurements have been made with a spheric probe, using the second-derivative method, and the results show that the energy distribution on the anode side of the sheath is a sum of a thermal population and an accelerated distribution. Near the sheath the accelerated electrons suffice to carry the discharge current, but far from it the current must be carried by an anisotropy in the thermal part of the distribution function. A comparison is made with calculated distributions. The cross-sections for electron-neutral and Coulomb collisions are not sufficient to account for the damping of the accelerated population, suggesting the presence of a plasma instability. In order to study the distribution function of the axial velocity component, preliminary measurements of the first derivative of the current to a plane probe have been made. Such measurements yield information about the anisotropy and the current transport, and may perhaps shed some light on the phenomenon of current limitation. Some measurements on a TIG welding arc are also described. (Auth.)

  3. Dose rate measuring device and dose rate measuring method using the same

    International Nuclear Information System (INIS)

    Urata, Megumu; Matsushita, Takashi; Hanazawa, Sadao; Konno, Takahiro; Chiba, Yoshinori; Yumitate, Tadahiro

    1998-01-01

    The device of the present invention comprises a scintillation fiber scope having a shape elongated in the direction of the height of a pressure vessel and emitting light by incident of radiation to detect radiation, a radioactivity measuring device for measuring a dose rate based on the detection of the fiber scope and a reel means for dispensing and taking up the fiber scope, and it constituted such that the dose rate of the pressure vessel and that of a shroud are determined independently. Then, when the taken out shroud is contained in an container, excessive shielding is not necessary, in addition, this device can reliably be inserted to or withdrawn from complicated places between the pressure vessel and the shroud, and further, the dose rate of the pressure vessel and that of the shroud can be measured approximately accurately even when the thickness of them is different greatly. (N.H.)

  4. Dose rate measuring device and dose rate measuring method using the same

    Energy Technology Data Exchange (ETDEWEB)

    Urata, Megumu; Matsushita, Takashi; Hanazawa, Sadao; Konno, Takahiro; Chiba, Yoshinori; Yumitate, Tadahiro

    1998-11-13

    The device of the present invention comprises a scintillation fiber scope having a shape elongated in the direction of the height of a pressure vessel and emitting light by incident of radiation to detect radiation, a radioactivity measuring device for measuring a dose rate based on the detection of the fiber scope and a reel means for dispensing and taking up the fiber scope, and it constituted such that the dose rate of the pressure vessel and that of a shroud are determined independently. Then, when the taken out shroud is contained in an container, excessive shielding is not necessary, in addition, this device can reliably be inserted to or withdrawn from complicated places between the pressure vessel and the shroud, and further, the dose rate of the pressure vessel and that of the shroud can be measured approximately accurately even when the thickness of them is different greatly. (N.H.)

  5. A comparison of statistically optimized near field acoustic holography using single layer pressure velocity measurements and using double layer pressure measurements

    DEFF Research Database (Denmark)

    Jacobsen, Finn; Chen, Xinyi; Jaud, Virginie

    2008-01-01

    recently been suggested. An alternative method uses a double layer array of pressure transducers. Both methods make it possible to distinguish between sources on the two sides of the array and thus suppress the influence of extraneous noise and reflections coming from the “wrong” side. This letter compares...

  6. Comparison of air-charged and water-filled urodynamic pressure measurement catheters.

    Science.gov (United States)

    Cooper, M A; Fletter, P C; Zaszczurynski, P J; Damaser, M S

    2011-03-01

    Catheter systems are utilized to measure pressure for diagnosis of voiding dysfunction. In a clinical setting, patient movement and urodynamic pumps introduce hydrostatic and motion artifacts into measurements. Therefore, complete characterization of a catheter system includes its response to artifacts as well its frequency response. The objective of this study was to compare the response of two disposable clinical catheter systems: water-filled and air-charged, to controlled pressure signals to assess their similarities and differences in pressure transduction. We characterized frequency response using a transient step test, which exposed the catheters to a sudden change in pressure; and a sinusoidal frequency sweep test, which exposed the catheters to a sinusoidal pressure wave from 1 to 30 Hz. The response of the catheters to motion artifacts was tested using a vortex and the response to hydrostatic pressure changes was tested by moving the catheter tips to calibrated heights. Water-filled catheters acted as an underdamped system, resonating at 10.13 ± 1.03 Hz and attenuating signals at frequencies higher than 19 Hz. They demonstrated significant motion and hydrostatic artifacts. Air-charged catheters acted as an overdamped system and attenuated signals at frequencies higher than 3.02 ± 0.13 Hz. They demonstrated significantly less motion and hydrostatic artifacts than water-filled catheters. The transient step and frequency sweep tests gave comparable results. Air-charged and water-filled catheters respond to pressure changes in dramatically different ways. Knowledge of the characteristics of the pressure-measuring system is essential to finding the best match for a specific application. Copyright © 2011 Wiley-Liss, Inc.

  7. Maximum respiratory pressure measuring system : calibration and evaluation of uncertainty

    NARCIS (Netherlands)

    Ferreira, J.L.; Pereira, N.C.; Oliveira Júnior, M.; Vasconcelos, F.H.; Parreira, V.F.; Tierra-Criollo, C.J.

    2010-01-01

    The objective of this paper is to present a methodology for the evaluation of uncertainties in the measurements results obtained during the calibration of a digital manovacuometer prototype (DM) with a load cell sensor pressure device incorporated. Calibration curves were obtained for both pressure

  8. A minimally invasive in-fiber Bragg grating sensor for intervertebral disc pressure measurements

    International Nuclear Information System (INIS)

    Dennison, Christopher R; Wild, Peter M; Wilson, David R; Cripton, Peter A

    2008-01-01

    We present an in-fiber Bragg grating (FBG) based intervertebral disc (IVD) pressure sensor that has pressure sensitivity seven times greater than that of a bare fiber, and a major diameter and sensing area of only 400 µm and 0.03 mm 2 , respectively. This is the only optical, the smallest and the most mechanically compliant disc pressure sensor reported in the literature. This is also an improvement over other FBG pressure sensors that achieve increased sensitivity through mechanical amplification schemes, usually resulting in major diameters and sensing lengths of many millimeters. Sensor sensitivity is predicted using numerical models, and the predicted sensitivity is verified through experimental calibrations. The sensor is validated by conducting IVD pressure measurements in porcine discs and comparing the FBG measurements to those obtained using the current standard sensor for IVD pressure. The predicted sensitivity of the FBG sensor matched with that measured experimentally. IVD pressure measurements showed excellent repeatability and agreement with those obtained from the standard sensor. Unlike the current larger sensors, the FBG sensor could be used in discs with small disc height (i.e. cervical or degenerated discs). Therefore, there is potential to conduct new measurements that could lead to new understanding of the biomechanics

  9. Measurement of intrahepatic pressure during radiofrequency ablation in porcine liver.

    Science.gov (United States)

    Kawamoto, Chiaki; Yamauchi, Atsushi; Baba, Yoko; Kaneko, Keiko; Yakabi, Koji

    2010-04-01

    To identify the most effective procedures to avoid increased intrahepatic pressure during radiofrequency ablation, we evaluated different ablation methods. Laparotomy was performed in 19 pigs. Intrahepatic pressure was monitored using an invasive blood pressure monitor. Radiofrequency ablation was performed as follows: single-step standard ablation; single-step at 30 W; single-step at 70 W; 4-step at 30 W; 8-step at 30 W; 8-step at 70 W; and cooled-tip. The array was fully deployed in single-step methods. In the multi-step methods, the array was gradually deployed in four or eight steps. With the cooled-tip, ablation was performed by increasing output by 10 W/min, starting at 40 W. Intrahepatic pressure was as follows: single-step standard ablation, 154.5 +/- 30.9 mmHg; single-step at 30 W, 34.2 +/- 20.0 mmHg; single-step at 70 W, 46.7 +/- 24.3 mmHg; 4-step at 30 W, 42.3 +/- 17.9 mmHg; 8-step at 30 W, 24.1 +/- 18.2 mmHg; 8-step at 70 W, 47.5 +/- 31.5 mmHg; and cooled-tip, 114.5 +/- 16.6 mmHg. The radiofrequency ablation-induced area was spherical with single-step standard ablation, 4-step at 30 W, and 8-step at 30 W. Conversely, the ablated area was irregular with single-step at 30 W, single-step at 70 W, and 8-step at 70 W. The ablation time was significantly shorter for the multi-step method than for the single-step method. Increased intrahepatic pressure could be controlled using multi-step methods. From the shapes of the ablation area, 30-W 8-step expansions appear to be most suitable for radiofrequency ablation.

  10. TH-AB-201-08: Ion Chamber Dose Measurements - Problems with the Temperature-Pressure Correction Factor

    Energy Technology Data Exchange (ETDEWEB)

    Bourgouin, A [Carleton University, Ottawa, Ontario (Canada); McEwen, M [National Research Council, Ottawa, ON (Canada)

    2016-06-15

    Purpose: To investigate the behavior of ionization chambers over a wide pressure range. Methods: Three cylindrical and two parallel-plate designs of ion chamber were investigated. The ion chambers were placed in vessel where the pressure was varied from atmospheric (101 kPa) down to 5 kPa. Measurements were made using 60Co and high-energy electron beams. The pressure was measured to better than 0.1% and multiple data sets were obtained for each chamber at both polarities to investigate pressure cycling and dependency on the sign of the charge collected. Results: For all types of chamber, the ionization current, corrected using the standard PTP, showed a similar behaviour. Deviations from the standard theory were generally small for Co-60 but very significant for electron beams, up to 20 % below P = 10 kPa. The effect was found to be always larger when collecting negative charge, suggesting a dependence on free-electron collection. The most likely source of such electrons is low-energy electrons emitted from the electrodes. This signal would be independent of air pressure within the chamber cavity. The data was analyzed to extract this signal and it was found to be a non-negligible component of the ionization current at atmospheric pressure. In the case of the parallel plate chambers, the effect was approximately 0.25 %. For the cylindrical chambers the effect was larger - up to 1.2 % - and dependent on the chamber type, which would be consistent with electron emission from different wall materials. For the electron beams, the correction factor was dependent on the electron energy and approximately double that observed in 60Co. Conclusion: Measurements have indicated significant deviations of the standard pressure correction that are consistent with electron emission from chamber electrodes. This has implications for both primary standard and reference ion chamber-based dosimetry.

  11. Microwave measurements of water vapor partial pressure at high temperatures

    International Nuclear Information System (INIS)

    Latorre, V.R.

    1991-01-01

    One of the desired parameters in the Yucca Mountain Project is the capillary pressure of the rock comprising the repository. This parameter is related to the partial pressure of water vapor in the air when in equilibrium with the rock mass. Although there are a number of devices that will measure the relative humidity (directly related to the water vapor partial pressure), they generally will fail at temperatures on the order of 150C. Since thee author has observed borehole temperatures considerably in excess of this value in G-Tunnel at the Nevada Test Site (NTS), a different scheme is required to obtain the desired partial pressure data at higher temperatures. This chapter presents a microwave technique that has been developed to measure water vapor partial pressure in boreholes at temperatures up to 250C. The heart of the system is a microwave coaxial resonator whose resonant frequency is inversely proportional to the square root of the real part of the complex dielectric constant of the medium (air) filling the resonator. The real part of the dielectric constant of air is approximately equal to the square of the refractive index which, in turn, is proportional to the partial pressure of the water vapor in the air. Thus, a microwave resonant cavity can be used to measure changes in the relative humidity or partial pressure of water vapor in the air. Since this type of device is constructed of metal, it is able to withstand very high temperatures. The actual limitation is the temperature limit of the dielectric material in the cable connecting the resonator to its driving and monitoring equipment-an automatic network analyzer in our case. In the following sections, the theory of operation, design, construction, calibration and installation of the microwave diagnostics system is presented. The results and conclusions are also presented, along with suggestions for future work

  12. Pressure test method for reactor pressure vessel in construction field

    International Nuclear Information System (INIS)

    Takeda, Masakado; Ushiroda, Koichi; Miyahara, Ryohei; Takano, Hiroshi; Matsuura, Tadashi; Sato, Keiya.

    1998-01-01

    Plant constitutional parts as targets of both of a primary pressure test and a secondary pressure test are disposed in communication with a reactor pressure vessel, and a pressure of the primary pressure test is applied to the targets of both tests, so that the primary pressure test and the second pressure test are conducted together. Since the number of pressure tests can be reduced to promote construction, and the number of workers can also be reduced. A pressure exceeding the maximum pressure upon use is applied to the pressure vessel after disposing the incore structures, to continuously conduct the primary pressure test and the secondary pressure test joined together and an incore flowing test while closing the upper lid of the pressure vessel as it is in the construction field. The number of opening/closing of the upper lid upon conducting every test can be reduced, and since the pressure resistance test is conducted after arranging circumference conditions for the incore flowing test, the tests can be conducted collectively also in view of time. (N.H.)

  13. Evaluation of the intraocular pressure measured with the ocular response analyzer.

    Science.gov (United States)

    Ogbuehi, Kelechi C; Almubrad, Turki M

    2010-07-01

    Comparison of the magnitude and repeatability of the intraocular pressure (IOP) measured with the Ocular Response Analyzer (ORA) to that measured with the Goldmann tonometer. Two sets of IOP measurements were made, for 89 eyes of eighty-nine subjects, approximately 1-week apart. Goldmann tonometry was performed subsequent to non-contact tonometry, in which the order of measurement was randomized between the ORA and the Topcon CT80 non-contact tonometer (CT80). Each method was assessed twice for intrasession repeatability. The limits of agreement between each non-contact pressure and that measured with the Goldmann tonometer were assessed once per session. The level of statistical significance was 0.05. The mean differences between the ORA-corneal compensated, Goldmann-correlated, and CT80-IOP (ORA-IOPcc; ORA-IOPg and CT80-IOP) versus the Goldmann IOP were -0.3 +/- 2.7 mmHg (mean +/- SD), -0.3 +/- 2.2 mmHg and -0.3 +/- 2.1 mmHg, respectively for session 1 and 0.3 +/- 3.0 mmHg, 0.2 +/- 2.2 mmHg, and -0.5 +/- 2.2 mmHg, respectively, for session 2. The repeatability coefficients were +/- 5.3 mmHg, +/- 4.2 mmHg, +/- 2.5 mmHg, and +/- 1.9 mmHg, respectively for ORA-IOPcc, ORA-IOPg, CT80-IOP, and Goldmann IOP in session 1 and +/- 3.8 mmHg, +/- 3.6 mmHg, +/- 1.6 mmHg, and +/- 1.9 mmHg, respectively for session 2. The repeatability indices for the ORA were poorer than those with the Goldmann tonometer and the CT80 in both sessions. However, the average IOP measured with the ORA did not vary significantly from those measured with the other two tonometers in either session. The ORA provides valid, repeatable measures of IOP.

  14. Driving Pressure Influence in Voltage Maps Measurement Process Using Advanced Pneumatic Mapping Probe

    Directory of Open Access Journals (Sweden)

    Marek Kukucka

    2016-01-01

    Full Text Available Our paper deals with the method of the voltage-impedance map measurement process as a method useful for the electric mapping of human skin. The area of research extends from the basic research to its practical application in acupuncture skin mapping and acupuncture point localization and visualization. The problem of sufficient skin coverage and electrical contact with measuring electrodes is solved by the conventional mechanical telescopic electrodes and by the pneumatic matrix electrode probe. A 2D or 3D voltage-impedance map of skin is an output of the measuring, interpretation and evaluation process. New pneumatic construction of measuring probe was implemented to achieve a better coverage of specified skin area and get a reduced force range of the touching electrodes allowing the steady contact of the skin-electrode. A skin contact is related to the driving pressure of touching electrodes. Our paper offers experimentally measured results, voltage maps of skin on specific areas, selected measured and described acupuncture points and their applications in electro-acupuncture.

  15. High-pressure behavior of amorphous selenium from ultrasonic measurements and Raman spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    He, Z.; Liu, X. R.; Hong, S. M., E-mail: hpswjtu@gmail.com, E-mail: smhong@home.swjtu.edu.cn [Laboratory of High Pressure Physics, Southwest Jiaotong University, Key Laboratory of Advanced Technologies of Materials, Ministry of Education of China, Chengdu 610031 (China); Wang, Z. G. [National Key Laboratory for Shock Wave and Detonation Physics Research, Institute of Fluid Physics, Chinese Academy of Engineering Physics, Mianyang 621900 (China); Zhu, H. Y. [State Key Laboratory of Superhard Materials, Jilin University, Changchun 130012 (China); Peng, J. P. [School of Physical Science and Technology, Southwest Jiaotong University, Chengdu 610031 (China)

    2014-07-07

    The high-pressure behavior of melt-quenched amorphous selenium (a-Se) has been investigated via ultrasonic measurements and Raman scattering at room temperature. The ultrasonic measurements were conducted on a-Se in a multi-anvil apparatus with two different sample assemblies at pressures of up to 4.5 and 4.8 GPa. We discovered that similar kinks occur in the slopes of the pressure dependence characteristics of the travel time and the sound velocity in both shear and longitudinal waves in the 2.0–2.5 GPa range. These kinks are independent of the sample assemblies, indicating an intrinsic transformation of the a-Se. Additionally, we deduced the pressure-volume relationship of a-Se from the sound velocity characteristics using the Birch–Murnaghan equation of state, and the results agreed well with those of previous reports. In situ high-pressure Raman scattering measurements of a-Se were conducted in a diamond anvil cell with an 830 nm excitation line up to a pressure of 4.3 GPa. We found that the characteristic band of a-Se at ∼250 cm{sup −1} experienced a smooth shift to a lower frequency with pressure, but a sharp slope change in the band intensity versus pressure occurred near 2.5 GPa. The results of X-ray diffraction and differential scanning calorimetry measurements indicate that the samples remain in their amorphous states after decompression. Thus, we proposed that the abnormal compression behavior of a-Se in the 2.0–2.5 GPa range can be attributed to pressure-induced local atomic reconfiguration, implying an amorphous-amorphous transition of the elementary selenium.

  16. Does the position or contact pressure of the stethoscope make any difference to clinical blood pressure measurements: an observational study.

    Science.gov (United States)

    Pan, Fan; Zheng, Dingchang; He, Peiyu; Murray, Alan

    2014-12-01

    This study aimed to investigate the effect of stethoscope position and contact pressure on auscultatory blood pressure (BP) measurement. Thirty healthy subjects were studied. Two identical stethoscopes (one under the cuff, the other outside the cuff) were used to simultaneously and digitally record 2 channels of Korotkoff sounds during linear cuff pressure deflation. For each subject, 3 measurements with different contact pressures (0, 50, and 100 mm Hg) on the stethoscope outside the cuff were each recorded at 3 repeat sessions. The Korotkoff sounds were replayed twice on separate days to each of 2 experienced listeners to determine systolic and diastolic BPs (SBP and DBP). Variance analysis was performed to study the measurement repeatability and the effect of stethoscope position and contact pressure on BPs. There was no significant BP difference between the 3 repeat sessions, between the 2 determinations from each listener, between the 2 listeners and between the 3 stethoscope contact pressures (all P > 0.06). There was no significant SBP difference between the 2 stethoscope positions at the 2 lower stethoscope pressures (P = 0.23 and 0.45), but there was a small (0.4 mm Hg, clinically unimportant) significant difference (P = 0.005) at the highest stethoscope pressure. The key result was that, DBP from the stethoscope under the cuff was significantly lower than that from outside the cuff by 2.8 mm Hg (P stethoscope outside the cuff, tends to give a higher DBP than the true intra-arterial pressure, this study could suggest that the stethoscope position under the cuff, and closer to the arterial occlusion, might yield measurements closer to the actual invasive DBP.

  17. The flow measurement methods for the primary system of integral reactors

    International Nuclear Information System (INIS)

    Lee, J.; Seo, J. K.; Lee, D. J.

    2001-01-01

    It is the common features of the integral reactors that the main components of the primary system are installed within the reactor vessel, and so there are no any flow pipes connecting the reactor coolant pumps or steam generators. Due to no any flow pipes, it is impossible to measure the differential pressure at the primary system of the integral reactors, and it also makes impossible measure the primary coolant flow rate. The objective of the study is to draw up the flow measurement methods for the primary system of integral reactors. As a result of the review, we have made a selection of the flow measurement method by pump speed, bt HBM, and by pump motor power as the flow measurement methods for the primary system of integral reactors. Peculiarly, we did not found out a precedent which the direct pump motor power-flow rate curve is used as the flow measurement method in the existing commercial nuclear power reactors. Therefore, to use this method for integral reactors, it is needed to bear the follow-up measures in mind. The follow-up measures is included in this report

  18. Synchronous Surface Pressure and Velocity Measurements of standard model in hypersonic flow

    Directory of Open Access Journals (Sweden)

    Zhijun Sun

    2018-01-01

    Full Text Available Experiments in the Hypersonic Wind tunnel of NUAA(NHW present synchronous measurements of bow shockwave and surface pressure of a standard blunt rotary model (AGARD HB-2, which was carried out in order to measure the Mach-5-flow above a blunt body by PIV (Particle Image Velocimetry as well as unsteady pressure around the rotary body. Titanium dioxide (Al2O3 Nano particles were seeded into the flow by a tailor-made container. With meticulous care designed optical path, the laser was guided into the vacuum experimental section. The transient pressure was obtained around model by using fast-responding pressure-sensitive paint (PSPsprayed on the model. All the experimental facilities were controlled by Series Pulse Generator to ensure that the data was time related. The PIV measurements of velocities in front of the detached bow shock agreed very well with the calculated value, with less than 3% difference compared to Pitot-pressure recordings. The velocity gradient contour described in accord with the detached bow shock that showed on schlieren. The PSP results presented good agreement with the reference data from previous studies. Our work involving studies of synchronous shock-wave and pressure measurements proved to be encouraging.

  19. Comparison of ambulatory blood pressure monitoring and office blood pressure measurements in obese children and adolescents.

    Science.gov (United States)

    Renda, Rahime

    2018-04-01

    Obesity in adults has been related to hypertension and abnormal nocturnal dipping of blood pressure, which are associated with poor cardiovascular and renal outcomes. Here, we aimed to resolve the relationship between the degree of obesity, the severity of hypertension and dipping status on ambulatory blood pressure in obese children. A total 72 patients with primary obesity aged 7 to 18 years (mean: 13.48 ± 3.25) were selected. Patients were divided into three groups based on body mass index (BMİ) Z-score. Diagnosis and staging of ambulatory hypertension based on 24-h blood pressure measurements, obtained from ambulatory blood pressure monitoring. Based on our ambulatory blood pressure data, 35 patients (48.6%) had hypertension, 7 (20%) had ambulatory prehypertension, 21 (60%) had hypertension, and 7 patients (20%) had severe ambulatory hypertension. There was a significant relationship between severity of hypertension and the degree of obesity (p lood pressure results and loads were similar between groups. Diastolic and mean arterial blood pressure levels during the night, diastolic blood pressure loads, and heart rate during the day were significantly higher in Group 3 (p lood pressure at night, mean arterial pressure at night, diastolic blood pressure loads and heart rate at day. Increase in BMI Z-score does not a significant impact on daytime blood pressure and nocturnal dipping status.

  20. Second measurement of morning systolic blood pressure is more closely associated with albuminuria.

    Science.gov (United States)

    Sakabe, Kazumi; Fukui, Michiaki; Ushigome, Emi; Hamaguchi, Masahide; Tanaka, Toru; Atsuta, Haruhiko; Ohnishi, Masayoshi; Oda, Yohei; Hasegawa, Goji; Nakamura, Naoto

    2012-08-01

    It is important to control blood pressure as well as to control blood glucose for the prevention of diabetic nephropathy. However, to our knowledge, there are no reports investigating which blood pressure, including morning, evening and clinic, is more closely associated with albuminuria and whether one measurement is sufficient or not in patients with Type 2 diabetes. We measured morning, evening and clinic blood pressure and compared the area under the curve (AUC) of blood pressure for urinary albumin excretion equal to or more than 30 mg/g creatinine using receiver-operating characteristic curve analyses and odds ratio for albuminuria defined as urinary albumin excretion equal to or more than 30 mg/g creatinine in 858 patients with Type 2 diabetes. Odds ratio (95% confidence interval (CI)) of morning, evening and clinic systolic blood pressure for albuminuria was 1.034 (1.024 - 1.044), 1.033 (1.023 - 1.043) and 1.013 (1.055 - 1.021), respectively (p AUC of morning, evening and clinic systolic blood pressure was 0.644 (0.628 - 0.700) (p AUC of the second morning systolic blood pressure was greater than the first (p = 0.033). The second measurement of morning systolic blood pressure is more closely associated with albuminuria than the first measurement of the morning in addition to clinic systolic blood pressure.