WorldWideScience

Sample records for metallic stent placement

  1. Radiologic placement of metallic esophageal stents: preliminary experience

    International Nuclear Information System (INIS)

    Good, S.; Asch, M.R.; Jaffer, N.; Casson, A.G.

    1997-01-01

    To assess the usefulness of covered, self expanding metallic stents for alleviating stricture associated with malignant esophageal lesions. Patients and methods: Self-expanding metallic stents were placed in 10 patients with dysphagia related to stricture caused by malignant esophageal lesions. The stents were placed fluoroscopically with local anesthesia, and patency of the esophageal lumen was assessed by barium study after the procedure. The patients were then followed clinically. Results: In all 10 cases patency of the lumen was renewed after stent placement. After the procedure 9 of the patients could tolerate a normal or near-normal diet; in the other patient esophageal perforation occurred, and clinical deterioration prevented oral intake of food. In one patient, 2 stents were needed because of the length of the stricture. Two patients experienced reflux after placement of the stent across the gastro-esophageal junction. Another patient had asymptomatic aspiration after stent placement in the proximal esophagus. In 2 patients, symptoms associated with tracheoesophageal fistula were relieved after placement of the stents. Six of the 10 patients died; mean survival after the procedure was 12 (range 1 to 56) weeks. The other 4 patients were alive at the time of writing, having survived for a mean of 7.5 (range 2 to 13) weeks; all of these patients tolerated a near-normal diet. Conclusions: The placement of covered, self-expanding metallic stents is a quick, effective method of palliating dysphagia related to stricture caused by malignant esophageal lesions. (author)

  2. Clinical outcomes of secondary stent-in-stent self-expanding metal stent placement for primary stent malfunction in malignant gastric outlet obstruction.

    Science.gov (United States)

    Park, Jun Chul; Park, Jae Jun; Cheoi, Kungseok; Chung, Hyunsoo; Lee, Hyuk; Shin, Sung Kwan; Lee, Sang Kil; Lee, Yong Chan

    2012-12-01

    Although a substantial number of patients require secondary stents insertion due to primary stent malfunction in malignant gastric outlet obstruction, data on the outcomes of secondary self-expanding metal stents are sparse. To investigate clinical outcomes and factors related with secondary stent malfunction in patients with malignant gastric outlet obstruction given secondary stent-in-stent self-expanding metal stent insertion. For this retrospective study, a total 77 patients who underwent secondary stent-in-stent self-expanding metal stent placement for primary stent malfunction in malignant gastric outlet obstruction were enrolled. We compared the effectiveness and complications of secondary covered and uncovered stents and explored the predictive factors for stent malfunction. Stent-in-stent self-expanding metal stent placements were technically successful in all patients. Both groups also had comparable clinical success rates (covered stent, 87.2% and uncovered stent, 90.0%, P = 1.000). Stent malfunction rates (31.9% and 36.7% respectively, P = 0.805) and median patency time of stent (165 [95% confidence interval: 112-218] and 165 [95% confidence interval: 126-204] days, respectively, P = 0.358) were similar between secondary covered and uncovered stents. Longer patients' survival time (≥ 100 days) was associated with increased risk of stent malfunction (odds ratio: 4.598; 95% confidence interval: 1.473-14.355; P = 0.009). Secondary stent-in-stent self-expanding metal stent placement is feasible and effective treatment for primary stent malfunctions in malignant gastric outlet obstruction. Covered and uncovered stent are equally acceptable in terms of stent-related complications and stent patency, regardless of primary stent type. Copyright © 2012 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  3. Self-expanding metal stent placement for oesophageal cancer ...

    African Journals Online (AJOL)

    This article documents the technique and periprocedural experience. Patients and methods. All patients who had SEMS placement for ... Repeat stenting was for stent migration (n=15), tumour overgrowth (n=26) and a blocked stent and a stricture (n=1 each). Complications were recorded in six cases (1.3%): iatrogenic TOF ...

  4. Hepatocellular Carcinoma Complicated by Gastroduodenal Obstruction: Palliative Treatment with Metallic Stent Placement

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ye Jin; Kim, Jin Hyoung, E-mail: m1fenew@daum.net; Song, Ho-Young; Park, Jung-Hoon; Na, Han Kyu; Kim, Pyeong Hwa; Fan, Yong [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center (Korea, Republic of)

    2012-10-15

    Purpose: To evaluate the clinical effectiveness of self-expandable metallic stents in seven patients with malignant gastroduodenal obstruction caused by inoperable hepatocellular carcinoma (HCC). Methods: Seven patients with gastroduodenal obstruction caused by advanced HCC underwent metallic stent placement from 2003 to 2010. These patients had total dysphagia (n = 5) or were able to eat only liquids (n = 2) before stent placement. Patients had Eastern Cooperative Oncology Group performance scores of 2 or 3, and Child-Pugh classification B or C. Results: Stent placement was technically successful in all seven patients (100%) and clinically successful in six (86%). Five patients could eat a soft diet, and one patient tolerated regular diet after stent placement. Stent-related obstructive jaundice occurred in one patient. One patient had hematemesis 11 days after stent placement. Overall mean survival was 51 days (range, 10-119 days). Stent patency was preserved in six patients with clinical success until death. Conclusion: Placement of a covered self-expandable metallic stent may offer good palliation in patients with gastroduodenal obstruction due to advanced HCC.

  5. Palliation of malignant gastric obstruction : fluoroscopic guided covered metallic stent placement

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Min; Han, Young Min; Kim, Chong Soo; Lee, Sang Yong; Choi, Ki Chul; Lee, Soo Tak [Department of Daignostic Radiology and Internal Medicine, Chonbuk National University Hospital, Chonju (Korea, Republic of); Han, Hyun Young [Department of Radiology, Eulgy University Hospital, Taejon (Korea, Republic of)

    2000-03-01

    To demonstrate the feasibility and clinical efficacy of self-expanding, covered metallic stent placement for the palliative treatment of malignant gastric obstruction. Under fluoroscopic guidance, the placement of self-expanding, covered stents was attempted in 23 patients (age range, 31-78 years) with inoperable or recurrent gastric malignancies. All 23 suffered dysphagia and/or vomiting after the ingestion of soft foods, or swallowing difficulty. Three different types of self-expanding, covered metallic stents were used and in all patients, these were placed perorally using over the guide wire technique. Success was defined both technically and clinically. Stent placement was technically successful in 19 patients (82.6%) but because the guidewire failed to successfully negotiate the sites at which there was obstruction, was unsuccessful in four (17.4%). Stent placement was well tolerated in all patients except one, in whom an acutely angled efferent loop from remnant stomach was present. In this case, stent placement required a strong metallic guidewire. After placement, 17 of the 19 patients (89.5%) were able to ingest solid and/or soft foods without dysphagia and showed a markedly decreased incidence of vomiting. Two others showed some improvement in the frequency of vomiting but were able to ingest only a liquid diet. In one patient, the stent migrated two days after the procedure. During the follow-up period of 2-7 months (mean, 74 days), there were no clinically significant complications. For the short-term palliative treatment of patients with gastric inlet or outlet obstruction, the placement of self-expanding metallic stents has proven relatively easy and safe, as well as reasonably effective. (author)

  6. Palliation of malignant gastric obstruction : fluoroscopic guided covered metallic stent placement

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Han, Young Min; Kim, Chong Soo; Lee, Sang Yong; Choi, Ki Chul; Lee, Soo Tak; Han, Hyun Young

    2000-01-01

    To demonstrate the feasibility and clinical efficacy of self-expanding, covered metallic stent placement for the palliative treatment of malignant gastric obstruction. Under fluoroscopic guidance, the placement of self-expanding, covered stents was attempted in 23 patients (age range, 31-78 years) with inoperable or recurrent gastric malignancies. All 23 suffered dysphagia and/or vomiting after the ingestion of soft foods, or swallowing difficulty. Three different types of self-expanding, covered metallic stents were used and in all patients, these were placed perorally using over the guide wire technique. Success was defined both technically and clinically. Stent placement was technically successful in 19 patients (82.6%) but because the guidewire failed to successfully negotiate the sites at which there was obstruction, was unsuccessful in four (17.4%). Stent placement was well tolerated in all patients except one, in whom an acutely angled efferent loop from remnant stomach was present. In this case, stent placement required a strong metallic guidewire. After placement, 17 of the 19 patients (89.5%) were able to ingest solid and/or soft foods without dysphagia and showed a markedly decreased incidence of vomiting. Two others showed some improvement in the frequency of vomiting but were able to ingest only a liquid diet. In one patient, the stent migrated two days after the procedure. During the follow-up period of 2-7 months (mean, 74 days), there were no clinically significant complications. For the short-term palliative treatment of patients with gastric inlet or outlet obstruction, the placement of self-expanding metallic stents has proven relatively easy and safe, as well as reasonably effective. (author)

  7. Placement of retrievable self-expandable metallic stents with barbs into patients with obstructive prostate cancer.

    Science.gov (United States)

    Song, Ho-Young; Kim, Choung Soo; Jeong, In Gab; Yoo, Dalsan; Kim, Jin Hyoung; Nam, Deok Ho; Bae, Jae-Ik; Park, Jung-Hoon

    2013-03-01

    To evaluate the technical feasibility and clinical effectiveness of retrievable self-expandable metallic stents with barbs in patients with obstructive prostate cancer. Retrievable self-expandable metallic stents with eight barbs each were inserted into eight consecutive patients with obstructive prostate cancer. Patient ages ranged from 55 to 76 years (mean, 69 years). All eight patients had previously received hormone therapy, and three had undergone palliative transurethral prostatectomy. Stents were removed using a 21-F stent removal set if they caused complications. Stent placement was technically successful and well tolerated in all patients. One had severe incontinence, which improved spontaneously, and two had gross haematuria, which disappeared spontaneously within 4 days. Peak urine flow rates and post-void residual urine volumes 1 month after stent placement were 5.6-10.2 ml/s (mean, 8.3 ml/s), and 5-45 ml (mean, 27 ml), respectively. During a mean follow-up of 192 days (range, 39-632 days), one patient required stent removal after 232 days because of stone formation within the stent. No further intervention was required because the mass improved after stent removal. These preliminary results suggest that retrievable stents with eight barbs are both feasible to place and effective in patients with obstructive prostate cancer.

  8. Self-Expandable Metallic Stent Placement in Malignant Gastric Outlet Obstruction: A Comparison Between 2 Brands of Stents.

    Science.gov (United States)

    Ye, Bing-Wei; Lee, Kuei-Chuan; Hsieh, Yun-Cheng; Li, Chung-Pin; Chao, Yee; Hou, Ming-Chih; Lin, Han-Chieh

    2015-07-01

    Malignant gastric outlet obstruction is a late complication of intraabdominal malignancy. Self-expandable metallic stent placement has been a safe palliative treatment to relieve obstructive symptoms. We aimed to assess the efficacy and safety of metallic stents in our patients and analyzed the clinical outcome of different brands. Seventy-one patients with inoperable gastric outlet obstruction receiving WallFlex enteral stents (WallFlex group) or Bonastents (Bonastent group) since April 2010 were analyzed retrospectively. The overall technical and clinical success rates of stent placement were 100% and 93%, respectively. The baseline characteristics and clinical outcomes including procedure-related complications, restenosis, and reintervention rates were comparable between the 2 groups. However, the Bonastent group had a higher rate of stent fracture than the WallFlex group (13.3% vs 0%, P = 0.03). The mean duration of overall stent patency was 132.7 days. The mean duration of survival was 181.9 days. Resumption of regular diet or low residual diet at day 7 after stent insertion predicted stent patency (hazard ratio [HR]: 0.28, P = 0.01). Cancer with gastric origin (HR: 0.25, P = 0.045) and poststent chemotherapy (HR: 0.38, P = 0.006) predicted lower mortality; however, peritoneal carcinomatosis (HR: 3.09, P = 0.04) correlated with higher mortality. Metallic stent placement is a safe and effective method for relieving gastric outlet obstruction. Except higher rate of stent fracture in the Bonastent group, there is no significant difference in clinical outcomes between the Bonastent group and the WallFlex group.

  9. Self-Expandable Metallic Stent Placement in Malignant Gastric Outlet Obstruction

    Science.gov (United States)

    Ye, Bing-Wei; Lee, Kuei-Chuan; Hsieh, Yun-Cheng; Li, Chung-Pin; Chao, Yee; Hou, Ming-Chih; Lin, Han-Chieh

    2015-01-01

    Abstract Malignant gastric outlet obstruction is a late complication of intraabdominal malignancy. Self-expandable metallic stent placement has been a safe palliative treatment to relieve obstructive symptoms. We aimed to assess the efficacy and safety of metallic stents in our patients and analyzed the clinical outcome of different brands. Seventy-one patients with inoperable gastric outlet obstruction receiving WallFlex enteral stents (WallFlex group) or Bonastents (Bonastent group) since April 2010 were analyzed retrospectively. The overall technical and clinical success rates of stent placement were 100% and 93%, respectively. The baseline characteristics and clinical outcomes including procedure-related complications, restenosis, and reintervention rates were comparable between the 2 groups. However, the Bonastent group had a higher rate of stent fracture than the WallFlex group (13.3% vs 0%, P = 0.03). The mean duration of overall stent patency was 132.7 days. The mean duration of survival was 181.9 days. Resumption of regular diet or low residual diet at day 7 after stent insertion predicted stent patency (hazard ratio [HR]: 0.28, P = 0.01). Cancer with gastric origin (HR: 0.25, P = 0.045) and poststent chemotherapy (HR: 0.38, P = 0.006) predicted lower mortality; however, peritoneal carcinomatosis (HR: 3.09, P = 0.04) correlated with higher mortality. Metallic stent placement is a safe and effective method for relieving gastric outlet obstruction. Except higher rate of stent fracture in the Bonastent group, there is no significant difference in clinical outcomes between the Bonastent group and the WallFlex group. PMID:26200641

  10. Self-expandable metal stent placement versus emergency resection for malignant proximal colon obstructions

    NARCIS (Netherlands)

    Amelung, F.J.; Draaisma, W.A.; Consten, E.C.; Siersema, P.D.; Borg, F. ter

    2017-01-01

    BACKGROUND: Traditionally, all patients with a malignant obstruction of the proximal colon (MOPC) are treated with emergency resection. However, recent data suggest that Self-expandable metallic stent (SEMS) placement could lower mortality and morbidity rates. This study therefore aimed to compare

  11. Covered self-expandable metallic stent placement for a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Woon Ha; Jung, Gyoo Sik; Kim, Kyu Jong; Lee, Sang Ho [Gospel Hospital, College of Medicine, Kosin University, Busan (Korea, Republic of); Ko, Ji Ho [Masan Samsung Medical Center, Sungkyunkwan University School of University, Masan (Korea, Republic of); Jeong, Kyung Soon [University of Ulsan Colleg of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2007-09-15

    To evaluate the technical feasibility and clinical effectiveness of stent placement for the treatment of a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer. Under fluoroscopic guidance, one or two covered stents were placed in 20 consecutive patients (age range, 44-75 years) with an anastomotic stricture due to a recurrent gastric malignancy. Before stent placement, all patients had severe nausea and recurrent vomiting after ingestion. Stent placement was technically successful for all patients, and no procedural complications occurred. After stent placement, 18 of 20 (90.0%) patients were able to ingest at least a liquid diet and had a markedly decreased incidence of vomiting. During the follow-up of 2-116 weeks (mean, 25.5 weeks), stent migration occurred in two patients (10.0%) on one day after the procedure. All patients with stent migration were treated successfully by means of placing a second stent. Three patients showed a recurrence of the stricture due to tumor overgrowth; two of the patients were treated with coaxial placement of a second stent. Another patient refused additional management. Covered self-expandable metallic stent placement seems to be technically feasible and effective for palliative treatment of a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer.

  12. Covered self-expandable metallic stent placement for a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer

    International Nuclear Information System (INIS)

    Lee, Woon Ha; Jung, Gyoo Sik; Kim, Kyu Jong; Lee, Sang Ho; Ko, Ji Ho; Jeong, Kyung Soon

    2007-01-01

    To evaluate the technical feasibility and clinical effectiveness of stent placement for the treatment of a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer. Under fluoroscopic guidance, one or two covered stents were placed in 20 consecutive patients (age range, 44-75 years) with an anastomotic stricture due to a recurrent gastric malignancy. Before stent placement, all patients had severe nausea and recurrent vomiting after ingestion. Stent placement was technically successful for all patients, and no procedural complications occurred. After stent placement, 18 of 20 (90.0%) patients were able to ingest at least a liquid diet and had a markedly decreased incidence of vomiting. During the follow-up of 2-116 weeks (mean, 25.5 weeks), stent migration occurred in two patients (10.0%) on one day after the procedure. All patients with stent migration were treated successfully by means of placing a second stent. Three patients showed a recurrence of the stricture due to tumor overgrowth; two of the patients were treated with coaxial placement of a second stent. Another patient refused additional management. Covered self-expandable metallic stent placement seems to be technically feasible and effective for palliative treatment of a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer

  13. Delayed ischemic cecal perforation despite optimal decompression after placement of a self-expanding metal stent: report of a case

    DEFF Research Database (Denmark)

    Knop, Filip Krag; Pilsgaard, Bo; Meisner, Søren

    2004-01-01

    Endoscopic deployment of self-expanding metal stents offers an alternative to surgical intervention in rectocolonic obstructions. Reported clinical failures in the literature are all related to the site of stent placement. We report a case of serious intra-abdominal disease after technically and ...

  14. Single-dose brachytherapy versus metal stent placement for the palliation of dysphagia from oesophageal cancer: multicentre randomised trial

    NARCIS (Netherlands)

    Homs, Marjolein Y. V.; Steyerberg, Ewout W.; Eijkenboom, Wilhelmina M. H.; Tilanus, Hugo W.; Stalpers, Lukas J. A.; Bartelsman, Joep F. W. M.; van Lanschot, Jan J. B.; Wijrdeman, Harm K.; Mulder, Chris J. J.; Reinders, Janny G.; Boot, Henk; Aleman, Berthe M. P.; Kuipers, Ernst J.; Siersema, Peter D.

    2004-01-01

    Background Both single-dose brachytherapy and self-expanding metal stent placement are commonly used for palliation of oesophageal obstruction due to inoperable cancer, but their relative merits are unknown. We under-took a randomised trial to compare the outcomes of brachytherapy and stent

  15. Self-expandable metallic stent placement plus laparoscopy for acute malignant colorectal obstruction

    Science.gov (United States)

    Zhou, Jia-Min; Yao, Li-Qing; Xu, Jian-Min; Xu, Mei-Dong; Zhou, Ping-Hong; Chen, Wei-Feng; Shi, Qiang; Ren, Zhong; Chen, Tao; Zhong, Yun-Shi

    2013-01-01

    AIM: To investigate the clinical advantages of the stent-laparoscopy approach to treat colorectal cancer (CRC) patients with acute colorectal obstruction (ACO). METHODS: From April 2008 to April 2012, surgery-related parameters, complications, overall survival (OS), and disease-free survival (DFS) of 74 consecutive patients with left-sided CRC presented with ACO who underwent self-expandable metallic stent (SEMS) placement followed by one-stage open (n = 58) or laparoscopic resection (n = 16) were evaluated retrospectively. The stent-laparoscopy group was also compared with a control group of 96 CRC patients who underwent regular laparoscopy without ACO between January 2010 and December 2011 to explore whether SEMS placement influenced the laparoscopic procedure or reduced long-term survival by influencing CRC oncological characteristics. RESULTS: The characteristics of patients among these groups were comparable. The rate of conversion to open surgery was 12.5% in the stent-laparoscopy group. Bowel function recovery and postoperative hospital stay were significantly shorter (3.3 ± 0.9 d vs 4.2 ± 1.5 d and 6.7 ± 1.1 d vs 9.5 ± 6.7 d, P = 0.016 and P = 0.005), and surgical time was significantly longer (152.1 ± 44.4 min vs 127.4 ± 38.4 min, P = 0.045) in the stent-laparoscopy group than in the stent-open group. Surgery-related complications and the rate of admission to the intensive care unit were lower in the stent-laparoscopy group. There were no significant differences in the interval between stenting and surgery, intraoperative blood loss, OS, and DFS between the two stent groups. Compared with those in the stent-laparoscopy group, all surgery-related parameters, complications, OS, and DFS in the control group were comparable. CONCLUSION: The stent-laparoscopy approach is a feasible, rapid, and minimally invasive option for patients with ACO caused by left-sided CRC and can achieve a favorable long-term prognosis. PMID:24023495

  16. Clinical outcomes of secondary gastroduodenal self-expandable metallic stent placement by stent-in-stent technique for malignant gastric outlet obstruction.

    Science.gov (United States)

    Sasaki, Takashi; Isayama, Hiroyuki; Nakai, Yousuke; Takahara, Naminatsu; Hamada, Tsuyoshi; Mizuno, Suguru; Mohri, Dai; Yagioka, Hiroshi; Kogure, Hirofumi; Arizumi, Toshihiko; Togawa, Osamu; Matsubara, Saburo; Ito, Yukiko; Yamamoto, Natsuyo; Sasahira, Naoki; Hirano, Kenji; Toda, Nobuo; Tada, Minoru; Koike, Kazuhiko

    2015-01-01

    To evaluate the efficacy and safety of secondary gastroduodenal stent placement after first stent dysfunction for malignant gastric outlet obstruction. We conducted a retrospective analysis to investigate the efficacy and safety of secondary stent-in-stent gastroduodenal stent placement. Among 260 patients who had been treated with first gastroduodenal stent placement for malignant gastric outlet obstruction, 29 patients (11.2%) were treated with secondary gastroduodenal stent placement because of first stent dysfunction. Pancreatic cancer was the major primary cancer (55.2%). A WallFlex duodenal stent was the most frequently inserted stent both as a first stent (75.9%) and as a secondary stent (62.1%). There were 22 patients (75.9%) that received gastroduodenal stents at the bending site (supraduodenal angle or infraduodenal angle). Technical and clinical success rates were 100% and 86.2%, respectively. Median eating period was 3.0 months, and median survival time was 3.5 months. As for related complications, gastrointestinal perforation, insufficient stent expansion, tumor ingrowth, tumor overgrowth, and cholangitis were experienced in 13.8% (four cases), 6.9% (two cases), 6.9% (two cases), 3.4% (one case), and 3.4% (one case), respectively. Secondary gastroduodenal stent placement might be effective for managing first stent dysfunction in malignant gastric outlet obstruction. However, gastrointestinal perforation was the major complication. © 2014 The Authors. Digestive Endoscopy © 2014 Japan Gastroenterological Endoscopy Society.

  17. Fluoroscopic-guided covered metallic stent placement for gastric outlet obstruction and post-operative gastroenterostomy anastomotic stricture

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Min; Han, Young Min; Kim, Chong Soo; Lee, Sang Young; Lee, Soo Teik; Yang, Doo Hyun

    2001-07-01

    AIM: To evaluate the feasibility and safety of fluoroscopic-guided covered metallic stent placements in providing palliative care for patients with inoperable malignant gastric outlet obstruction. MATERIALS AND METHODS: Under fluoroscopic guidance, placement of self-expandable, covered stents was attempted in 20 patients with inoperable or recurrent gastric cancer (age range 36-79 years). All patients had inoperable gastric outlet obstruction, 13 with native anatomy and seven with post-operative anatomy (gastrointestinal anastomotic sites). All patients had intolerance to oral alimentation and/or vomiting after ingestion. Success was defined both technically and clinically. RESULTS: The placement of the stent was technically successful in 18 patients and failed in two patients (technical success: 90%). The cause of the technical failures was an inability to negotiate the guide wire through the obstruction sites in spite of the use of both fluoroscopic and endoscopic guidance. After stent placement, 15 patients were able to ingest at least liquids and had a markedly decreased incidence of vomiting (clinical success: 75%). During the mean follow-up of 6 weeks, there have been no stent reocclusion and no life-threatening complications except migration of two stents in one patient. CONCLUSION: Fluoroscopically guided covered metallic stent placement appears to be valuable for the palliative treatment of malignant obstruction of gastric outlet and post-operative gastrointestinal anastomoses. Lee, J.M. et al. (2001)

  18. Fluoroscopic-guided covered metallic stent placement for gastric outlet obstruction and post-operative gastroenterostomy anastomotic stricture

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Han, Young Min; Kim, Chong Soo; Lee, Sang Young; Lee, Soo Teik; Yang, Doo Hyun

    2001-01-01

    AIM: To evaluate the feasibility and safety of fluoroscopic-guided covered metallic stent placements in providing palliative care for patients with inoperable malignant gastric outlet obstruction. MATERIALS AND METHODS: Under fluoroscopic guidance, placement of self-expandable, covered stents was attempted in 20 patients with inoperable or recurrent gastric cancer (age range 36-79 years). All patients had inoperable gastric outlet obstruction, 13 with native anatomy and seven with post-operative anatomy (gastrointestinal anastomotic sites). All patients had intolerance to oral alimentation and/or vomiting after ingestion. Success was defined both technically and clinically. RESULTS: The placement of the stent was technically successful in 18 patients and failed in two patients (technical success: 90%). The cause of the technical failures was an inability to negotiate the guide wire through the obstruction sites in spite of the use of both fluoroscopic and endoscopic guidance. After stent placement, 15 patients were able to ingest at least liquids and had a markedly decreased incidence of vomiting (clinical success: 75%). During the mean follow-up of 6 weeks, there have been no stent reocclusion and no life-threatening complications except migration of two stents in one patient. CONCLUSION: Fluoroscopically guided covered metallic stent placement appears to be valuable for the palliative treatment of malignant obstruction of gastric outlet and post-operative gastrointestinal anastomoses. Lee, J.M. et al. (2001)

  19. Endoscopic stenting for hilar cholangiocarcinoma: efficacy of unilateral and bilateral placement of plastic and metal stents in a retrospective review of 480 patients

    Directory of Open Access Journals (Sweden)

    Liberato Manuel José

    2012-08-01

    Full Text Available Abstract Background Endoscopic biliary drainage of hilar cholangiocarcinoma is controversial with respect to the optimal types of stents and the extent of drainage. This study evaluated endoscopic palliation in patients with hilar cholangiocarcinoma using self-expandable metallic stents (SEMS and plastic stents (PS.We also compared unilateral and bilateral stent placement according to the Bismuth classification. Methods Data on 480 patients receiving endoscopic biliary drainage for hilar cholangiocarcinoma between September 1995 and December 2010 were retrospectively reviewed to evaluate the following outcome parameters: technical success (TS, functional success (FS, early and late complications, stent patency and survival. Patients were followed from stent insertion until death or stent occlusion. Patients were divided into 3 groups according to the Bismuth classification (Group 1, type I; Group 2, type II; Group 3, type > III. Results The initial stent insertion was successful in 450 (93.8% patients. TS was achieved in 204 (88.3% patients treated with PS and in 246 (98.8% patients palliated with SEMS (p P P  Conclusions SEMS insertion for the palliation of hilar cholangiocarcinoma offers higher technical and clinical success rates in the ITT analysis as well as lower complication rates and a superior cumulative stent patency when compared with PS placement in all Bismuth classifications. The cumulative patency of bilateral SEMS or PS stents was significantly higher than that of unilateral SEMS or PS stents, with lower occlusion rates in Bismuth II patients.

  20. Metallic stent placement for the management of acute colorectal obstruction caused by colorectal carcinomas: its effect on scheduled surgery

    International Nuclear Information System (INIS)

    Cao Yan; Liu Bingyan; Mao Aiwu; Yin Xiang; Gao Zhongdu

    2011-01-01

    Objective: To prospectively evaluate the safety and clinical efficacy of a newly designed self-expandable metallic stent (SEMS) placement in the treatment of patients with acute malignant colorectal obstruction due to colorectal carcinomas. Methods: During the period from April 2001 to October 2007, a total of 52 patients with acute malignant colorectal obstruction were treated with stent placement by using a new designed SEMS, which was employed as a preoperative transit means. All the patients were followed up and the relevant data, including technical success rate, clinical efficacy, complications and overall survival rate, were documented. The results were analyzed. Results: Stent placement was successfully carried out in all patients except for two patients who showed complete colorectal obstruction. No procedure-related complications occurred. Technical success rate was 96% (50/52). Two days after the treatment, the relief rate of colorectal obstruction was 98% (49/50). Postoperative complications included stent migration (n=4), anal pain (n=2) and stool impaction (n=1). The stool impaction seen in one patient was successfully removed away with endoscopic manipulation two days after stent placement. An elective one-stage surgical procedure was performed in all 50 patients who successfully received a SEMS placement within a mean interval of (8±2) days (ranged 4-11 days) after stent placement. Mean follow-up time was (36±12) months with a range of (3-70) months. All patients remained alive at the time of this report. Conclusion: The newly designed SEMS placement used as a preoperative transit means is a safe and effective intervention for colonic decompression in patients with acute malignant colorectal obstruction due to colorectal carcinomas. It can reliably ensure most of patients with colorectal carcinomas to successfully accomplish an elective surgery. (authors)

  1. Palliative metallic stent placement for managing esophageal cancer of the aging

    International Nuclear Information System (INIS)

    Li Qnqi; Yin Huabin; Yue Wei; Ji Chengzhou; Yang Yufeng

    2000-01-01

    Objective: To evaluate the effectiveness of self-expanding metallic stent in the treatment of the old patients with malignant esophageal stricture. Methods: 32 old patients with malignant esophageal stricture were treated with covered self-expandable metallic stents, 32 stents were placed by X-TV guiding, without pre-dilatation of the stenosis by balloon catheter. Results: All 32 stents were successfully placed, the successful rate was 100%. All of the patients obtained the improvement of the food intake ability. No fatal stent-related complications occurred. The average survival time was 6.5 months. Conclusions: The covered self-expandable metallic stent is effective in the palliative management of malignant esophageal stricture of the aging

  2. Improvement of quality of life and survival using self-expandable metal stent placement for severe malignant stenosis of the gastric body: a case report.

    Science.gov (United States)

    Kumagai, Hozumi; Nio, Kenta; Shirakawa, Tsuyoshi; Uchino, Keita; Kusaba, Hitoshi; Isobe, Taichi; Komoda, Masato; Tamura, Shingo; Maeyama, Ryo; Nagai, Eishi; Akashi, Koichi; Baba, Eishi

    2012-09-19

    Advanced gastric carcinoma often decreases quality of life because of upper gastrointestinal tract stenosis. Self-expandable metal stents have been thought to be an effective, minimally invasive treatment for stenosis. However, the effectiveness of self-expandable metal stent placement for carcinomatous stenosis of the gastric body and antrum has not been clarified, and there have been few reports of such cases. A 74-year-old Japanese woman developed stenosis of the gastric body and antrum caused by advanced gastric cancer during first-line chemotherapy. She developed weight loss and poor nutrition due to inadequate intake. Self-expandable metal stent placement for stenosis of the gastric body and antrum ameliorated her symptoms rapidly and improved her general condition and quality of life. Eight days after self-expandable metal stent placement, second-line chemotherapy could be administered safely. Oral intake and nutritional status were maintained for 117 days after self-expandable metal stent placement, and she died of gastric cancer 176 days after self-expandable metal stent placement and initiation of second-line chemotherapy. Self-expandable metal stent placement for carcinomatous stenosis in the gastric body and antrum could be an effective therapeutic strategy for patients with inadequate oral uptake. It may provide rapid improvement of the patient's general condition and oral intake with minimal complications, comparatively long-term symptom relief, and a survival benefit by allowing second-line chemotherapy.

  3. Impact of Carcinomatosis on Clinical Outcomes after Self-Expandable Metallic Stent Placement for Malignant Gastric Outlet Obstruction.

    Science.gov (United States)

    Lee, Ji Eun; Lee, Keol; Hong, Yun Soo; Kim, Eun Ran; Lee, Hyuk; Min, Byung-Hoon

    2015-01-01

    It is still unclear whether the peritoneal carcinomatosis had a negative effect on the clinical outcomes of patients who underwent self-expandable metallic stent (SEMS) placement for malignant gastric outlet obstruction (GOO). Although carcinomatosis may be associated with the development of multifocal gastrointestinal (GI) tract obstruction or decreased bowel movement, previous studies investigated the occurrence of stent failure only and thus had limitation in evaluating clinical outcomes of patients with carcinomatosis. Between 2009 and 2013, 155 patients (88 patients without carcinomatosis and 67 patients with carcinomatosis) underwent endoscopic SEMS placement for malignant GOO. Factors affecting clinical success and obstructive symptom-free survival (time period between SEMS placement and the recurrence of obstructive symptoms due to multifocal GI tract obstruction or decreased bowel movement as well as stent failure) were assessed. Patients with carcinomatosis showed higher Eastern Cooperative Oncology Group (ECOG) scale than those without carcinomatosis. Clinical success rates were 88.1% in patients with carcinomatosis and 97.7% in patients without carcinomatosis. In multivariate analysis, only ECOG scale was identified as an independent predictor of clinical success. During follow-up period, patients with carcinomatosis showed significantly shorter obstructive symptom-free survival than those without carcinomatosis. In multivariate analysis, the presence of carcinomatosis, chemotherapy or radiation therapy after SEMS placement, and obstruction site were identified as independent predictors of obstructive symptom-free survival. For patient without carcinomatosis, stent failure accounted for the recurrence of obstructive symptoms in 84.6% of cases. For patients with carcinomatosis, multifocal GI tract obstruction or decreased bowel movement accounted for 37.9% of cases with obstructive symptom recurrence and stent failure accounted for 44.8% of cases

  4. Impact of Carcinomatosis on Clinical Outcomes after Self-Expandable Metallic Stent Placement for Malignant Gastric Outlet Obstruction.

    Directory of Open Access Journals (Sweden)

    Ji Eun Lee

    Full Text Available It is still unclear whether the peritoneal carcinomatosis had a negative effect on the clinical outcomes of patients who underwent self-expandable metallic stent (SEMS placement for malignant gastric outlet obstruction (GOO. Although carcinomatosis may be associated with the development of multifocal gastrointestinal (GI tract obstruction or decreased bowel movement, previous studies investigated the occurrence of stent failure only and thus had limitation in evaluating clinical outcomes of patients with carcinomatosis.Between 2009 and 2013, 155 patients (88 patients without carcinomatosis and 67 patients with carcinomatosis underwent endoscopic SEMS placement for malignant GOO. Factors affecting clinical success and obstructive symptom-free survival (time period between SEMS placement and the recurrence of obstructive symptoms due to multifocal GI tract obstruction or decreased bowel movement as well as stent failure were assessed.Patients with carcinomatosis showed higher Eastern Cooperative Oncology Group (ECOG scale than those without carcinomatosis. Clinical success rates were 88.1% in patients with carcinomatosis and 97.7% in patients without carcinomatosis. In multivariate analysis, only ECOG scale was identified as an independent predictor of clinical success. During follow-up period, patients with carcinomatosis showed significantly shorter obstructive symptom-free survival than those without carcinomatosis. In multivariate analysis, the presence of carcinomatosis, chemotherapy or radiation therapy after SEMS placement, and obstruction site were identified as independent predictors of obstructive symptom-free survival. For patient without carcinomatosis, stent failure accounted for the recurrence of obstructive symptoms in 84.6% of cases. For patients with carcinomatosis, multifocal GI tract obstruction or decreased bowel movement accounted for 37.9% of cases with obstructive symptom recurrence and stent failure accounted for 44.8% of

  5. Percutaneous Placement of Permanent Metallic Stents in the Cystic Duct to Treat Obstructive Cholecystitis.

    Science.gov (United States)

    Brown, Nicholas I; Jhamb, Ashu; Brooks, Duncan M; Little, Andrew F

    2015-12-01

    This report presents a series of five patients unsuitable for surgery who had nonretrievable self-expanding metallic stents deployed along the cystic duct as treatment for benign and malignant causes of gallbladder obstruction. Techniques are described for draining cholecystitis, removing gallstones, bypassing gallbladder obstructions, and inserting metallic stents across the cystic duct to restore permanent antegrade gallbladder drainage in acute and chronic cholecystitis. Symptoms resolved in all cases, and stents remained patent for as long as 22 months. This procedure may be an effective alternative to cholecystectomy or long-term gallbladder drainage for patients in inoperable condition. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.

  6. Self-expandable metallic stent placement for patients with inoperable esophageal carcinoma. Investigation of the influence of prior radiotherapy and chemotherapy

    International Nuclear Information System (INIS)

    Ihara, Yuko; Murayama, Sadayuki; Toita, Takafumi; Utsunomiya, Takashi; Nagata, Osamu; Akamine, Tamaki; Ogawa, Kazuhiko; Adachi, Genki; Tanigawa, Noboru

    2006-01-01

    The aim of this study was to evaluate the efficacy and complications of self-expandable metallic stent placement for patients with inoperable esophageal carcinoma after radiotherapy and/or chemotherapy. We obtained data from 19 patients with advanced or recurrent esophageal carcinoma between 1996 and 2000. In all patients, a self-expandable metallic stent was placed under fluoroscopic guidance. Dysphagia before and after stent placement was graded. Complications after stent placement were also evaluated. Data were compared between patients with and without prior radiotherapy and/or chemotherapy. The procedure was technically successful in all but one patient. The dysphagia grade improved in all patients. No life-threatening complications occurred. The other major complications such as mediastinitis occurred in two patients, and pneumonia and funnel phenomenon occurred in one patient each. These patients had a history of radiotherapy and/or chemotherapy prior to stent placement. Eight of the twelve patients with prior radiotherapy and/or chemotherapy compared with one of seven patients without prior therapy had persistent chest pain, which was a statistically significant difference (P<0.05). Placement of self-expandable metallic stents was effective for patients with advanced or recurrent esophageal carcinoma. However, prior irradiation and/or chemotherapy increased the risk of persistent chest pain after stent placement. (author)

  7. Percutaneous unilateral biliary metallic stent placement in patients with malignant obstruction of the biliary hila and contralateral portal vein steno-occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Son, Rak Chae; Gwon, Dong Il; Ko, Heung Kyu; Kim, Jong Woo; Ko, Gi Young [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2015-06-15

    To investigate the outcomes of percutaneous unilateral metallic stent placement in patients with a malignant obstruction of the biliary hila and a contralateral portal vein steno-occlusion. Sixty patients with a malignant hilar obstruction and unilobar portal vein steno-occlusion caused by tumor invasion or preoperative portal vein embolization were enrolled in this retrospective study from October 2010 to October 2013. All patients were treated with percutaneous placement of a biliary metallic stent, including expanded polytetrafluoroethylene (ePTFE)-covered stents in 27 patients and uncovered stents in 33 patients. A total of 70 stents were successfully placed in 60 patients. Procedural-related minor complications, including self-limiting hemobilia (n = 2) and cholangitis (n = 4) occurred in six (10%) patients. Acute cholecystitis occurred in two patients. Successful internal drainage was achieved in 54 (90%) of the 60 patients. According to a Kaplan-Meier analysis, median survival time was 210 days (95% confidence interval [CI], 135-284 days), and median stent patency time was 133 days (95% CI, 94-171 days). No significant difference in stent patency was observed between covered and uncovered stents (p = 0.646). Stent dysfunction occurred in 16 (29.6%) of 54 patients after a mean of 159 days (range, 65-321 days). Unilateral placement of ePTFE-covered and uncovered stents in the hepatic lobe with a patent portal vein is a safe and effective method for palliative treatment of patients with a contralateral portal vein steno-occlusion caused by an advanced hilar malignancy or portal vein embolization. No significant difference in stent patency was detected between covered and uncovered metallic stents.

  8. Percutaneous placement of self-expandable metallic stents in patients with obstructive janudice secondary to metastalic gastric cancer after gastrectomy

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Hyun Pyo [Dept. of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Seo, In Ho; Yu, Jung Rim; Mok, Young Jae; Oh, Joo Hyeong [Korea University Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of); Kwon, Se Hwan [Dept. of Radiology, Kyung Hee University Medical Center, Seoul (Korea, Republic of); Kim, Sam Soo [Dept. of Radiology, Kangwon National University College of Medicine, Chuncheon (Korea, Republic of); Kim, Seung Kwon [Division of Interventional Radiology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis (United States)

    2013-10-15

    To evaluate the outcomes of patients undergoing percutaneous placements of a biliary stent for obstructive jaundice secondary to metastatic gastric cancer after gastrectomy. Fifty patients (mean age, 62.4 years; range, 27-86 years) who underwent percutaneous placements of a biliary stent for obstructive jaundice secondary to metastatic gastric cancer after gastrectomy were included. The technical success rate, clinical success rate, complication rate, stent patency, patient survival and factors associated with stent patency were being evaluated. The median interval between the gastrectomy and stent placement was 23.1 months (range, 3.9-94.6 months). The 50 patients received a total of 65 stents without any major procedure-related complications. Technical success was achieved in all patients. The mean total serum bilirubin level, which had been 7.19 mg/dL ± 6.8 before stent insertion, decreased to 4.58 mg/dL ± 5.4 during the first week of follow-up (p < 0.001). Clinical success was achieved in 42 patients (84%). Percutaneous transhepatic biliary drainage catheters were removed from 45 patients (90%). Infectious complications were noted in two patients (4%), and stent malfunction occurred in seven patients (14%). The median stent patency was 233 ± 99 days, and the median patient survival was 179 ± 83 days. Total serum bilirubin level after stenting was an independent factor for stent patency (p = 0.009). Percutaneous transhepatic placement of a biliary stent for obstructive jaundice secondary to metastatic gastric cancer after gastrectomy is a technically feasible and clinically effective palliative procedure.

  9. Predictors of outcomes in patients undergoing covered and uncovered self-expandable metal stent placement for malignant gastric outlet obstruction: a multicenter study.

    Science.gov (United States)

    Hori, Yasuki; Naitoh, Itaru; Hayashi, Kazuki; Ban, Tesshin; Natsume, Makoto; Okumura, Fumihiro; Nakazawa, Takahiro; Takada, Hiroki; Hirano, Atsuyuki; Jinno, Naruomi; Togawa, Shozo; Ando, Tomoaki; Kataoka, Hiromi; Joh, Takashi

    2017-02-01

    Uncovered self-expandable metal stents (U-SEMSs) and covered self-expandable metal stents (C-SEMSs) are available for palliative therapy for malignant gastric outlet obstruction (GOO). However, clinical differences and indications between the 2 types of SEMSs have not been elucidated. We retrospectively compared 126 patients with U-SEMS and 126 patients with C-SEMSs with regard to clinical outcome and factors predictive of clinical improvement after SEMSs placement. No significant difference was observed between the U-SEMS and C-SEMS groups with respect to technical success, clinical success, GOO score, or time to stent dysfunction. Stent migration was significantly more frequent in patients with C-SEMSs (U-SEMSs, .79%; C-SEMSs, 8.73%; P = .005). Karnofsky performance status, chemotherapy, peritoneal dissemination, and stent expansion ≤ 30% were associated significantly with poor GOO score improvement in multivariable analyses, but stent type was not (P = .213). In subgroup analyses, insufficient (≤30%) stent expansion was an independent factor in patients with U-SEMSs (P = .041) but not C-SEMSs. In the insufficient stent expansion subgroup, C-SEMSs was associated significantly with superior clinical improvement compared with U-SEMSs (P = .01). Insufficient stent expansion was observed more frequently in patients with GI obstruction because of anastomotic sites or metastatic cancer (44.8% [13/29], P = .001). No clinical difference, apart from stent migration, was observed between patients with U-SEMSs and C-SEMSs. GI obstruction because of an anastomotic site or metastatic cancer may be an indication for C-SEMS use to improve oral intake after SEMSs placement. Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  10. Endoscopic stent placement throughout the gastrointestinal tract

    NARCIS (Netherlands)

    van den Berg, M.W.

    2014-01-01

    In this thesis we focussed our research on stent placement throughout the GI tract. In search for ideal stents for treatment of malignant oesophageal stenosis and gastric outlet obstruction we evaluated new stent designs in prospective cohort studies. Smaller research projects mainly aimed to

  11. Self-expandable metal stent placement for the palliation of malignant gastroduodenal obstruction: experience in a large, single, UK centre

    International Nuclear Information System (INIS)

    Lowe, A.S.; Beckett, C.G.; Jowett, S.; May, J.; Stephenson, S.; Scally, A.; Tam, E.; Kay, C.L.

    2007-01-01

    Aim: To assess the technical success rate, and evaluate the clinical outcome, length of hospital stay, and cost of palliative gastro-duodenal stenting in a single-centre. Materials and methods: Eight-seven patients referred for insertion of a gastroduodenal stent between April 1999 and April 2004 were recruited to a non-randomized, before and after intervention study performed in a single centre. Demographic data, diagnosis and symptoms along with clinical and technical outcomes were recorded. Results: The technical success rate was 84/87 (96.6%), with inability to traverse the stricture in three patients. No immediate complications were demonstrated. There was marked improvement after stent placement with resolution of symptoms and commencement of dietary intake in 76 patients (87%). Stenting resulted in improved quality of life as reflected by an increase in Karnofsky score from 44/100, to 63/100 post-procedure. Late complications included perforation (n = 1), migration (n = 1) and stent occlusions due to tumour ingrowth/overgrowth (n = 7; mean 165 days). Mean survival was 107 days (range 0-411 days). Median hospital stay post-stent placement was 5.5 days (range 1-55 days) with a majority of patients (75%) discharged home. The mean cost of each treatment episode was Pounds 4146 ($7132 $US, Euro 6,028 EUROS). Conclusion: The present series confirms that combined endoscopic and radiological gastroduodenal stenting is a highly favourable treatment for patients with inoperable malignant gastric outlet obstruction. The results suggest that this minimally invasive procedure has a very high technical success rate, whilst at the same time providing excellent palliation of symptoms with improved quality of life in the majority of patients

  12. Self-expandable metal stent placement for the palliation of malignant gastroduodenal obstruction: experience in a large, single, UK centre

    Energy Technology Data Exchange (ETDEWEB)

    Lowe, A.S. [Department of Clinical Radiology, Bradford Royal Infirmary (United Kingdom)]. E-mail: andy.lowe@bradfordhospitals.nhs.uk; Beckett, C.G. [Department of Gastroenterology, Bradford Royal Infirmary (United Kingdom); Jowett, S. [Department of Gastroenterology, Bradford Royal Infirmary (United Kingdom); May, J. [Department of Surgery, Bradford Royal Infirmary (United Kingdom); Stephenson, S. [Department of Clinical Radiology, Bradford Royal Infirmary (United Kingdom); Scally, A. [School of Health Studies, Bradford (United Kingdom); Tam, E. [Department of Clinical Radiology, Bradford Royal Infirmary (United Kingdom); Kay, C.L. [Department of Clinical Radiology, Bradford Royal Infirmary (United Kingdom)

    2007-08-15

    Aim: To assess the technical success rate, and evaluate the clinical outcome, length of hospital stay, and cost of palliative gastro-duodenal stenting in a single-centre. Materials and methods: Eight-seven patients referred for insertion of a gastroduodenal stent between April 1999 and April 2004 were recruited to a non-randomized, before and after intervention study performed in a single centre. Demographic data, diagnosis and symptoms along with clinical and technical outcomes were recorded. Results: The technical success rate was 84/87 (96.6%), with inability to traverse the stricture in three patients. No immediate complications were demonstrated. There was marked improvement after stent placement with resolution of symptoms and commencement of dietary intake in 76 patients (87%). Stenting resulted in improved quality of life as reflected by an increase in Karnofsky score from 44/100, to 63/100 post-procedure. Late complications included perforation (n = 1), migration (n = 1) and stent occlusions due to tumour ingrowth/overgrowth (n = 7; mean 165 days). Mean survival was 107 days (range 0-411 days). Median hospital stay post-stent placement was 5.5 days (range 1-55 days) with a majority of patients (75%) discharged home. The mean cost of each treatment episode was Pounds 4146 ($7132 $US, Euro 6,028 EUROS). Conclusion: The present series confirms that combined endoscopic and radiological gastroduodenal stenting is a highly favourable treatment for patients with inoperable malignant gastric outlet obstruction. The results suggest that this minimally invasive procedure has a very high technical success rate, whilst at the same time providing excellent palliation of symptoms with improved quality of life in the majority of patients.

  13. Stent placement for tracheal stenosis in patients with esophageal cancer

    International Nuclear Information System (INIS)

    Takagi, Keigo; Hata, Yoshinobu; Sasamoto, Shuichi; Takahashi, Shoji; Sato, Fumitomo; Tamaki, Kazuyoshi; Goto, Hidenori; Yuasa, Rena

    2011-01-01

    Tracheal invasion including tracheal bifurcation due to esophageal cancer can sometimes cause serious complications of the airway, but such cases sometimes improve quickly following chemoradiation treatment. The absolute indications for stent replacement in the airway for this disorder and the optimal choice of stent are herein discussed. Between 1992 and 2010, 28 patients with airway stenosis, including 7 patients with esophago-tracheal fistula, were treated by placement of various stents; namely, 12 patients received Dumon stents, 3 patients had Dynamic stents, 10 patients were given Ultraflex stents, while 3 other patients were treated without the use of stents. Severe dyspnea in the supine position was observed, which mainly originated from invasion to the membranous portion of the trachea. Airway patency was maintained after stent replacement, although the median survival time of such cases was only 4 months. Three patients with severe dyspnea who could lie in a supine position recovered after undergoing chemoradiation treatment without stent replacement. No cases of stent removal were observed after chemoradiation treatment. Chemoradiation treatment for esophageal cancer was found to be effective for the management of airway disturbances, and thus the absolute indications for stent replacement are restricted to patients who cannot lie in a supine position due to severe impairment of ventilation during radiation therapy, as well as patients presenting with tracheobroncho-esophageal fistula. Concerning stent selection, a metal stent should be the first choice for tracheal stenosis due to its ease of insertion, because there is no substantial difference between silicone and metal stents regarding the treatment of tracheal stenosis. However, it is important to note that a silicone Y stent is useful for the treatment of tracheal bifurcation. (author)

  14. Stent graft placement for dysfunctional arteriovenous grafts

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Gyeong Sik [Dept. of Radiology, CHA Bundang Medical Center, College of Medicine, CHA University, Seongnam (Korea, Republic of); Shin, Byung Seok; Ohm, Joon Young; Ahn, Moon Sang [Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2015-07-15

    This study aimed to evaluate the usefulness and outcomes of stent graft use in dysfunctional arteriovenous grafts. Eleven patients who underwent stent graft placement for a dysfunctional hemodialysis graft were included in this retrospective study. Expanded polytetrafluoroethylene covered stent grafts were placed at the venous anastomosis site in case of pseudoaneurysm, venous laceration, elastic recoil or residual restenosis despite the repeated angioplasty. The patency of the arteriovenous graft was evaluated using Kaplan-Meier analysis. Primary and secondary mean patency was 363 days and 741 days. Primary patency at 3, 6, and 12 months was 82%, 73%, and 32%, respectively. Secondary patency at the 3, 6, 12, 24, and 36 months was improved to 91%, 82%, 82%, 50%, and 25%, respectively. Fractures of the stent graft were observed in 2 patients, but had no effect on the patency. Stent graft placement in dysfunctional arteriovenous graft is useful and effective in prolonging graft patency.

  15. Self-Expandable Metal Stent Placement for Closure of a Leak after Total Gastrectomy for Gastric Cancer: Report on Three Cases and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Dario Raimondo

    2014-01-01

    Full Text Available In the setting of the curative oncological surgery, the gastric surgery is exposed to complicated upper gastrointestinal leaks, and consequently the management of this problem has become more critically focused than was previously possible. We report here three cases of placement of a partially silicone-coated SEMS (Evolution Controlled Release Esophageal Stent System, Cook Medical, Winston-Salem, NC, USA in patients who underwent total gastrectomy with Roux-en-Y end-to-side esophagojejunostomy for a gastric adenocarcinoma. The promising results of our report, despite the small number of patients, suggest that early stenting (through a partially silicone-coated SEMS is a feasible alternative to surgical treatment in this subset of patients. In fact, in the treatment of leakage after total gastrectomy, plastic stents and totally covered metallic stents may not adhere sufficiently to the esophagojejunal walls and, as a result, migrate beyond the anastomosis. However, prospective studies with a larger number of patients might assess the real effectiveness and safety of this procedure.

  16. Self-Expandable Metallic Stent Placement in the Palliative Treatment of Malignant Obstruction of Gastric Outlet and Duodenum

    Science.gov (United States)

    Dobrucali, Ahmet

    2013-01-01

    Background/Aims To asses the usefulness of flexible metallic stents in the palliation of malignant obstruction of gastric outlet and duodenum. Methods Retrospective review was performed between January 2006 and December 2011 in 30 patients. Thirty consecutive patients with obstruction of the gastric outlet underwent palliative treatment with self-expandable flexible metallic stents. Complications and clinical outcomes were assessed. Results Twenty-four patients had advanced gastric carcinoma at the antrum and/or pylorus, four patients had obstruction at the pylorus due to pancreas tumours and one patient had duodedum and one patient had gall bladder tumour. Symptoms improved in 82.7% of the patients after the procedure. The improvement in ability to eat using the score system was statistically significant (pgastric outlet obstruction caused by stomach or pancreas cancer. PMID:23423384

  17. [Eleven Patients with Gastric Cancer Who Received Chemotherapy after Stent Placement for Gastric Outlet Obstruction].

    Science.gov (United States)

    Endo, Shunji; Nakagawa, Tomo; Konishi, Ken; Ikenaga, Masakazu; Ohta, Katsuya; Nakashima, Shinsuke; Matsumoto, Kenichi; Nishikawa, Kazuhiro; Ohmori, Takeshi; Yamada, Terumasa

    2017-01-01

    Endoscopic placement of self-expandable metallic stents is reportedly effective for gastric outlet obstructions due to advanced gastric cancer, and is less invasive than gastrojejunostomy. For patients who have good performance status, we administer chemotherapy after stent placement, although the safety and feasibility of this chemotherapy have not yet been discussed in full. Between 2011 and 2015, 15 patients at our institution underwent endoscopic gastroduodenal stent placement for gastric outlet obstruction due to gastric cancer. Eleven of these patients were administered chemotherapy after stent placement. In our case series, we did not observe any specific adverse event caused by stent placement plus chemotherapy. Adverse events after chemotherapy included anemia of CTCAE Grade 3 in 7 patients. Stent-in-stent placement was needed in 2 patients. Neither stent migration nor perforation was observed. Therefore, chemotherapy after stent placement for gastric outlet obstruction due to gastric cancer was considered safe and feasible. Stent placement is useful not only as palliative care for patients with terminal-stage disease, but also as one of the multimodal therapeutic strategies for gastric cancer.

  18. Stent placement for esophageal strictures : an update

    NARCIS (Netherlands)

    Hirdes, Meike Madeleine Catharine; Vleggaar, Frank Paul; Siersema, Peter Derk

    2011-01-01

    The use of stents for esophageal strictures has evolved rapidly over the past 10 years, from rigid plastic tubes to flexible self-expanding metal (SEMS), plastic (SEPS) and biodegradable stents. For the palliative treatment of malignant dysphagia both SEMS and SEPS effectively provide a rapid relief

  19. Angioplasty and stent placement - peripheral arteries

    Science.gov (United States)

    ... blood flow. A stent is a small, metal mesh tube that keeps the artery open. Angioplasty and ... Shreveport, Shreveport, LA. Review provided by VeriMed Healthcare Network. Also reviewed by David Zieve, MD, MHA, Medical ...

  20. Metallic intratracheal stent application on relapsing polychondritis with severe tracheobronchial malacia

    International Nuclear Information System (INIS)

    Ao Guokun; Zhao Weiguo; Guo Qinyun; Huang Qin

    2007-01-01

    Objective: To evaluate the therapeutic and adverse effects of metallic intratracheal stent placement in relapsing polychondritis with severe tracheobronchial malaeia. Methods: Five tracheal stents had been implanted in three patients with tracheobronchial malaeia. One patient was implanted with two tubular stents in trachea and one 'Y' shaped stent for bilateral bronchi. Another patient used a tubular stent in total tracheal segment. The last patient used a tubular stent in the upper segment of trachea. Results: All the stents were implanted successfully with obvious improvement of dyspnea after the treatment. Conclusions: Metallic intratracheal stent placement can really relieve symptoms and improve the life quality in patients with tracheobronchial malacia caused by relapsing polychondritis. (authors)

  1. Clinical application of hepatic vein percutaneous transluminal angioplasty and stent after stent placement in inferior vena cava

    International Nuclear Information System (INIS)

    Xu Hao; Zu Maoheng; Gu Yuming; Li Guojun; Zhang Qingqiao; Wei Ning; Xu Wei; Liu Hongtao

    2005-01-01

    Objective: To investigate the feasibility and effect of recanalization of hepatic vein with percutaneous transluminal angioplasty (PTA) and stent after stent placement in inferior vena cava (IVC). Methods: Eleven patients with Budd-Chiari syndrome (BCS)were once performed metal stent placement in IVC at other hospital, but ascites was not subsided in 9 patients after the stent placement and occurred again in 2 patients in 3 months after the procedure. PTA and metal stent placement were used to treat the occlusion of the hepatic vein (HV) via stent in IVC. Results: Recanalization of occlusive HV was successful in all 11 patients, and symptoms disappeared or were obviously improved. The mean blood pressure in HV dropped from pre-operation (45.12 ± 1.57) cm H 2 O (1 cm H 2 O=0.098 kPa) to post-operation (17.53 ± 0.68) cm H 2 O (P<0.01). In a period of 4-30 months (mean: 13.6 months) following-up, no patient reoccurred symptoms. Conclusion: Recanalization of HV via stent in IVC is a feasible and effective method for occlusive HV, but it is difficult. (authors)

  2. Placement of an implantable port catheter in the biliary stent: an experimental study in dogs

    International Nuclear Information System (INIS)

    Ko, Gi Young; Lee, Im Sick; Choi, Won Chan

    2004-01-01

    To investigate the feasibility of port catheter placement following a biliary stent placement. We employed 14 mongrel dogs as test subject and after the puncture of their gaIl bladders using sonographic guidance, a 10-mm in diameter metallic stent was placed at the common duct. In 12 dogs, a 6.3 F port catheter was placed into the duodenum through the common duct and a port was secured at the subcutaneous space following stent placement. As a control group, an 8.5 F drain tube was placed into the gallbladder without port catheter placement in the remaining two dogs. Irrigation of the bile duct was performed every week by injection of saline into the port, and the port catheter was replaced three weeks later in two dogs. Information relating to the success of the procedure, complications and the five-week follow-up cholangiographic findings were obtained. Placement of a biliary stent and a port catheter was technically successful in 13 (93%) dogs, while stent migration (n=3), gallbladder rupture (n=1) and death (n=5) due to subcutaneous abscess and peritonitis also occurred. The follow-up was achieved in eight dogs (seven dogs with a port catheter placement and one dog with a drain tube placement). Irrigation of the bile duct and port catheter replacement were successfully achieved without any complications. Cholangiograms obtained five weeks after stent placement showed diffuse biliary dilation with granulation tissue formation. However, focal biliary stricture was seen in one dog with stent placement alone. Placement of a port catheter following biliary stent placement seems to be feasible. However, further investigation is necessary to reduce the current complications

  3. Placement of an implantable port catheter in the biliary stent: an experimental study in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Gi Young; Lee, Im Sick; Choi, Won Chan [Asan Medical Center, Seoul (Korea, Republic of)

    2004-04-01

    To investigate the feasibility of port catheter placement following a biliary stent placement. We employed 14 mongrel dogs as test subject and after the puncture of their gaIl bladders using sonographic guidance, a 10-mm in diameter metallic stent was placed at the common duct. In 12 dogs, a 6.3 F port catheter was placed into the duodenum through the common duct and a port was secured at the subcutaneous space following stent placement. As a control group, an 8.5 F drain tube was placed into the gallbladder without port catheter placement in the remaining two dogs. Irrigation of the bile duct was performed every week by injection of saline into the port, and the port catheter was replaced three weeks later in two dogs. Information relating to the success of the procedure, complications and the five-week follow-up cholangiographic findings were obtained. Placement of a biliary stent and a port catheter was technically successful in 13 (93%) dogs, while stent migration (n=3), gallbladder rupture (n=1) and death (n=5) due to subcutaneous abscess and peritonitis also occurred. The follow-up was achieved in eight dogs (seven dogs with a port catheter placement and one dog with a drain tube placement). Irrigation of the bile duct and port catheter replacement were successfully achieved without any complications. Cholangiograms obtained five weeks after stent placement showed diffuse biliary dilation with granulation tissue formation. However, focal biliary stricture was seen in one dog with stent placement alone. Placement of a port catheter following biliary stent placement seems to be feasible. However, further investigation is necessary to reduce the current complications.

  4. Metallic Stents for Tracheobronchial Pathology Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Serrano, Carolina, E-mail: carolina.serrano@unizar.es [University of Zaragoza, Surgical Pathology Unit, Animal Pathology Department (Spain); Laborda, Alicia, E-mail: alaborda@unizar.es [University of Zaragoza, Minimally Invasive Techniques Research Group (GITMI) (Spain); Lozano, Juan M., E-mail: juamauloz@gmail.com [Marly Clinic, Radiology Department (Colombia); Caballero, Hugo, E-mail: hugocaballero2007@gmail.com [Marly Clinic, Pulmonology Department (Colombia); Sebastian, Antonio, E-mail: antonio.sebastian@ono.es [Lozano Blesa Clinical University Hospital, Pulmonology Department (Spain); Lopera, Jorge, E-mail: lopera@uthscsa.edu [Health Science Center, Interventional Radiology Deparment (United States); Gregorio, Miguel Angel de, E-mail: mgregori@unizar.es [University of Zaragoza, Minimally Invasive Techniques Research Group (GITMI) (Spain)

    2013-12-15

    Purpose: To present the 7-year experience of the treatment of benign and malignant tracheobronchial stenoses using metallic stents. Patients and Methods: One hundred twenty-three stents were inserted in 86 patients (74 benign and 12 malignant stenoses). Ninety-seven stents were placed in the trachea and 26 in the bronchi. The procedures were performed under fluoroscopic and flexible bronchoscopic guidance with the patient under light sedation. In cases of severe stenotic lesions or obstructions, laser resection was performed before stent placement. Clinical and functional pulmonary data were recorded before and 3 months after the procedure. Follow-up involved clinical data and radiographic techniques at 48 h and at 1-, 3-, 6-, and 12-month intervals. Results: The technical success was 100 %. Dyspnea disappearance, forced expiratory volume in the first second, and pulmonary functional data improvement was observed in all patients (p < 0.001). Complications were detected in 23 patients (26.7 %). Mean follow-up time was 6.3 {+-} 1.2 months in patients with malignant lesions and 76.2 {+-} 2.3 months patients with in benign lesions. By the end of the study, 100 % of patients with malignant pathology and 6.7 % of patients with benign lesions had died. Conclusion: Endoluminal treatment of tracheobronchial stenosis with metallic stents is a therapeutic alternative in patients who are poor candidates for surgery. In unresectable malignant lesions, the benefit of metallic stenting is unquestionable. In benign lesions, the results are satisfactory, but sometimes other interventions are required to treat complications. New stent technology may improve these results.

  5. Metallic stents for tracheobronchial pathology treatment.

    Science.gov (United States)

    Serrano, Carolina; Laborda, Alicia; Lozano, Juan M; Caballero, Hugo; Sebastián, Antonio; Lopera, Jorge; de Gregorio, Miguel Ángel

    2013-12-01

    To present the 7-year experience of the treatment of benign and malignant tracheobronchial stenoses using metallic stents. One hundred twenty-three stents were inserted in 86 patients (74 benign and 12 malignant stenoses). Ninety-seven stents were placed in the trachea and 26 in the bronchi. The procedures were performed under fluoroscopic and flexible bronchoscopic guidance with the patient under light sedation. In cases of severe stenotic lesions or obstructions, laser resection was performed before stent placement. Clinical and functional pulmonary data were recorded before and 3 months after the procedure. Follow-up involved clinical data and radiographic techniques at 48 h and at 1-, 3-, 6-, and 12-month intervals. The technical success was 100 %. Dyspnea disappearance, forced expiratory volume in the first second, and pulmonary functional data improvement was observed in all patients (p < 0.001). Complications were detected in 23 patients (26.7 %). Mean follow-up time was 6.3 ± 1.2 months in patients with malignant lesions and 76.2 ± 2.3 months patients with in benign lesions. By the end of the study, 100 % of patients with malignant pathology and 6.7 % of patients with benign lesions had died. Endoluminal treatment of tracheobronchial stenosis with metallic stents is a therapeutic alternative in patients who are poor candidates for surgery. In unresectable malignant lesions, the benefit of metallic stenting is unquestionable. In benign lesions, the results are satisfactory, but sometimes other interventions are required to treat complications. New stent technology may improve these results.

  6. Neuroendoscopic stent placement for cerebrospinal fluid pathway obstructions in adults.

    Science.gov (United States)

    Marx, Sascha; Fleck, Steffen K; El Refaee, Ehab; Manwaring, Jotham; Vorbau, Christina; Fritsch, Michael J; Gaab, Michael R; Schroeder, Henry W S; Baldauf, Joerg

    2016-09-01

    OBJECTIVE Since its revival in the early 1990s, neuroendoscopy has become an integral component of modern neurosurgery. Endoscopic stent placement for treatment of CSF pathway obstruction is a rarely used and underestimated procedure. The authors present the first series of neuroendoscopic intracranial stenting for CSF pathway obstruction in adults with associated results and complications spanning a long-term follow-up of 20 years. METHODS The authors retrospectively reviewed a prospectively maintained clinical database for endoscopic stent placement performed in adults between 1993 and 2013. RESULTS Of 526 endoscopic intraventricular procedures, stents were placed for treatment of CSF disorders in 25 cases (4.8%). The technique was used in the management of arachnoid cysts (ACs; n = 8), tumor-related CSF disorders (n = 13), and hydrocephalus due to stenosis of the foramen of Monro (n = 2) or aqueduct (n = 2). The mean follow-up was 87.1 months. No deaths or infections occurred that were related to endoscopic placement of intracranial stents. Late stent dislocation or migration was observed in 3 patients (12%). CONCLUSIONS Endoscopic intracranial stent placement in adults is rarely required but is a safe and helpful technique in select cases. It is indicated when reliable and long-lasting restoration of CSF pathway obstructions cannot be achieved with standard endoscopic techniques. In the treatment of tumor-related hydrocephalus, it is a good option to avoid reclosure of the restored CSF pathway by tumor growth. Currently, routine stent placement after endoscopic fenestration of ACs is not recommended. Stent placement for treatment of CSF disorders due to tumor is a good option for avoiding CSF shunting. To avoid stent migration and dislocation, and to allow for easy removal if needed, the device should be fixed to a bur hole reservoir.

  7. Usefulness of a guiding sheath for fluoroscopic stent placement in patients with malignant gastroduodenal obstruction.

    Science.gov (United States)

    Park, Jung-Hoon; Song, Ho-Young; Kim, Myoung Sun; Chung, Rosa; Kim, Jin Hyoung; Na, Han Kyu; Nam, Deok Ho

    2013-04-01

    Self-expandable metallic stent placement is widely used to manage malignant gastroduodenal obstructions. However, there are difficulties in negotiating a guidewire (GW) and a stent delivery system (SDS). To investigate feasibility, usefulness, and safety of a guiding sheath for fluoroscopic stent placement in patients with malignant gastroduodenal obstructions. In July 2001 to August 2011, 726 patients with malignant gastroduodenal obstructions underwent stent placement. Guiding sheath was used in patients in whom a GW could not be passed through the obstruction and a SDS failed to reach the obstruction. Sheath usefulness was evaluated based on the ability of the sheath to successfully assist. The technical success rate and the most frequent reasons for the use of a sheath were evaluated. The guiding sheath was needed in 148 of 726 patients (20%). The overall technical success rate was 98% with the guiding sheath. In two of 148 patients, stent placement failed because, the GW could not be passed through the obstruction, in the other, the SDS could not be passed. A minority of patients reported mild discomfort. Patients with pancreatic cancer and duodenal obstruction were significantly more likely to require the use of guiding sheaths (P = 0.002, P guiding sheath for fluoroscopic stent placement appears to be feasible, useful and safe in patients with malignant gastroduodenal obstructions.

  8. Endoscopic trimming of metallic stents with the use of argon plasma

    NARCIS (Netherlands)

    Christiaens, Paul; Decock, Sofie; Buchel, Otto; Bulté, Katrien; Moons, Veerle; D'Haens, Geert; van Olmen, Gust

    2008-01-01

    The endoscopic placement of metallic stents for palliation of malignant obstruction of the GI or biliary tract is an established practice and as such is often applied. Use of these stents, however, has its problems. Stent migration may cause obstruction of the bowel lumen. Migration of a biliary

  9. Usefulness of a Guiding Sheath for Fluoroscopic Colorectal Stent Placement

    Science.gov (United States)

    Nam, Deok Ho; Lee, Heuiran

    2012-01-01

    Objective To investigate the technical feasibility, clinical usefulness, and safety of a guiding sheath in fluoroscopic stent placement for patients with malignant colorectal obstructions. Materials and Methods Between June 2007 and January 2011, fluoroscopic placement of a dual colorectal stent was attempted in a total of 97 patients with malignant colorectal obstructions. A polytetrafluoroethylene guiding sheath was used in patients in whom a stent delivery system failed to reach the obstruction. Usefulness of the sheath was evaluated depending on whether the sheath could successfully assist the stent delivery system reach its area of interest. Results The guiding sheath was needed in 22 patients (15 men, 7 women; age range, 33-77 years; mean age, 59 years). The overall success rate for passing the sheath to the area of interest was 100%. There were no procedure-related deaths or major complications. The majority of the patients reported mild discomfort. In 2 of 22 patients with successful passing of the sheath to the area of interest, stent placement failed because of failure in the negotiation of a guide wire through the obstruction. Conclusion Using a guiding sheath seems to be easy, safe and useful in fluoroscopic stent placement for patients with malignant colorectal obstructions. PMID:22563292

  10. Stent placement of gastroenteric anastomoses formed by magnetic compression.

    Science.gov (United States)

    Cope, C; Clark, T W; Ginsberg, G; Habecker, P

    1999-01-01

    To evaluate the use of stents for prolonging the patency of gastroenteric anastomoses (GEA) induced by magnet compression. Rare earth magnets were inserted perorally and serially in 15 dogs so as to mate across the gastric and jejunal walls. After magnet excretion, the resulting GEA was identified endoscopically, dilated (n = 1), and stented with bare (n = 2) or partially covered (n = 6) flared 10-mm or 12-mm Z stents. The GEA was followed at 2-4-week intervals for patency; malfunctioning shunts were irrigated, or dilated with angioplasty balloons. Gross and histologic examination of the anastomotic tissues was performed in 14 animals. Magnet pairs were excreted in 5-7 days. Of the 19 magnet placements in 15 animals, stent placement was not possible because of early GEA closure (n = 6), failure to locate (n = 2), pancreatic abscess (n = 1), and magnet perforation with peritonitis (n = 1). Estimated duration of GEA patency was 19 days after balloon dilation, 40-64 days with bare Z stents, and 58-147 days (mean, 90 days) with partially covered Z stents. Shunt function was commonly hindered by bezoars. Stent narrowing or occlusion was caused by tissue overgrowth through bare stents (n = 2), between covered stent struts and through partially detached membrane (n = 2). Serious morbidity (n = 2) was due to malpositioned magnets across the pancreas in one animal and gastric perforation in the other. One dog was euthanized because of unsuspected kidney infection. Partially covered stents significantly extend the anatomic patency rate of magnetic GEA to 7 weeks or more. Functional patency is frequently impaired by bezoars. Ongoing improvements in covered stent design should provide longer-term GEA patency.

  11. Placement of a triple-layered covered versus uncovered metallic stent for palliation of malignant gastric outlet obstruction: a multicenter randomized trial.

    Science.gov (United States)

    Maetani, Iruru; Mizumoto, Yoshinori; Shigoka, Hiroaki; Omuta, Shigefumi; Saito, Michihiro; Tokuhisa, Junya; Morizane, Toshio

    2014-03-01

    Usually, uncovered self-expandable metallic stents (SEMS) are used for palliation of malignant gastric outlet obstruction (GOO). A triple-layered covered SEMS is reported to be efficacious, but its performance has not been compared with uncovered SEMS. The present study is the first to compare the efficacy and safety of a triple-layered covered versus uncovered SEMS. A multicenter randomized study was conducted in two tertiary referral centers, with 62 eligible patients with symptomatic GOO to receive covered (n = 31) or uncovered SEMS (n = 31). The primary endpoint was SEMS patency, and secondary endpoints were success rate and adverse events after complete follow up. Both groups had a technical success rate of 100% and comparable clinical success rates (P = 0.67). There was nostatistically significant difference in stent patency and adverse events between the two groups (P = 0.52 and P = 0.38, respectively). Although the occurrence rate of persistent obstructive symptoms was comparable (P = 0.42), that of recurrent obstructive symptoms was higher in the uncovered group (29% vs 3.6%, P = 0.0125). Patient survival did not differ between groups (P = 0.34). There was no statistically significant difference in stent patency, but use of a triple-layered covered SEMS was associated with less frequent stent dysfunction more than 4 weeks after stenting, despite similar short-term outcomes. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.

  12. Resolution of Metallic Biliary Stent Allergic Reaction After Partial Stent Removal in a Patient with Nickel Sensitivity.

    Science.gov (United States)

    Esparaz, Anthony M; Ahmed, Muneeb

    2017-07-01

    Local and systemic reactions to implanted metallic devices, particularly to those containing nickel, are well documented. Metal ions are released due to exposure of the metal to blood, proteins, other body fluids, and sheer mechanical stress. Metal ions then complex with native proteins and become antigens, which can elicit hypersensitivity reactions. Another case report depicts a specific allergic complication (early stent occlusion) related to metallic biliary stent implantation. We present a case of allergic symptoms, associated with eating, in a patient who developed nickel sensitivity after biliary metal stent placement confirmed by allergic skin testing to the same metallic biliary stent placed one year earlier. Symptoms resolved following partial removal of the non-epithelialized portion of the biliary stent.

  13. Tracheal Penetration and Tracheoesophageal Fistula Caused by an Esophageal Self-Expanding Metallic Stent

    Science.gov (United States)

    Madan, Karan; Venuthurimilli, Arun; Ahuja, Vineet; Mohan, Anant; Guleria, Randeep

    2014-01-01

    Tracheal penetration of esophageal self-expanding metallic stents (SEMS) with/without tracheoesophageal fistula (TEF) formation is a rare occurrence. We report the case of a 66-year-old female patient with advanced esophageal squamous cell carcinoma who had undergone palliative esophageal stenting on three occasions for recurrent esophageal stent obstruction. On evaluation of symptoms of breathing difficulty and aspiration following third esophageal stent placement, tracheal erosion and TEF formation due to the tracheal penetration by esophageal stent were diagnosed. The patient was successfully managed by covered tracheal SEMS placement under flexible bronchoscopy. PMID:25276461

  14. Tracheal Penetration and Tracheoesophageal Fistula Caused by an Esophageal Self-Expanding Metallic Stent

    Directory of Open Access Journals (Sweden)

    Karan Madan

    2014-01-01

    Full Text Available Tracheal penetration of esophageal self-expanding metallic stents (SEMS with/without tracheoesophageal fistula (TEF formation is a rare occurrence. We report the case of a 66-year-old female patient with advanced esophageal squamous cell carcinoma who had undergone palliative esophageal stenting on three occasions for recurrent esophageal stent obstruction. On evaluation of symptoms of breathing difficulty and aspiration following third esophageal stent placement, tracheal erosion and TEF formation due to the tracheal penetration by esophageal stent were diagnosed. The patient was successfully managed by covered tracheal SEMS placement under flexible bronchoscopy.

  15. Metallic stents provide better QOL than plastic stents in patients with stricture of unresectable advanced esophageal cancer

    International Nuclear Information System (INIS)

    Ohta, Kazuki; Nagahara, Akihito; Iijima, Katsuyori

    2006-01-01

    The aim of this study was to elucidate the utility and safety of treatment with esophageal stents (plastic and metallic stents) for unresectable advanced esophageal cancer. Between 1992 and 2002, 14 cases of unresectable advanced esophageal cancer were treated with esophageal stents (the plastic stent group, 7 cases; and the metallic stent group, 7 cases). Of these, 10 cases had a history of chemotherapy and or radiotherapy. An improvement in oral intake and performance status (PS), survival time, periods at home, and adverse events were compared between the two groups. After stenting, oral intake and PS were significantly improved in the metallic stent group. Follow-up at home was possible in 71.4%. There was no significant difference in survival or duration of time at home between the two groups. All adverse events were controllable and there was no difference between the two groups. Stenting not only improved oral intake and PS but also allowed a stay at home, resulting in a marked improvement in patients' quality of life (QOL). Stenting was performed safely even in cases with a history of radiotherapy. There was no difference in survival, ratios of staying at home, and safety between the two groups, but QOL was significantly improved in the metallic stent group. These outcomes indicate that placement of metallic stents should be actively considered to treat stricture due to advanced esophageal cancer. (author)

  16. Angioplasty and stent placement - carotid artery - discharge

    Science.gov (United States)

    ... have also had a stent (a tiny wire mesh tube) placed in the blocked area to keep ... Stony Brook, NY. Review provided by VeriMed Healthcare Network. Also reviewed by David Zieve, MD, MHA, Medical ...

  17. Biliary drainage of the common bile duct with an enteral metal stent

    NARCIS (Netherlands)

    dek, I.M.; van den Elzen, B.D.J.; Fockens, P.; Rauws, E.A.J.

    2009-01-01

    In this case report we present an elderly patient who was referred to our hospital with recurrent episodes of cholangitis that persisted after placement of five metal stents for a distal common bile duct (CBD) stenosis. All metal stents were endoscopically removed from the CBD by forceps after

  18. Advantages of laparoscopic stented choledochorrhaphy over T-tube placement.

    Science.gov (United States)

    Isla, A M; Griniatsos, J; Karvounis, E; Arbuckle, J D

    2004-07-01

    Postoperative complications after laparoscopic choledochotomy are mainly related to the T tube. Both laparoscopic endobiliary stent placement with primary closure of the common bile duct (CBD) and primary closure of the CBD without drainage have been proposed as safe and effective alternatives to T tube placement. This was a retrospective analysis of data collected prospectively on 53 consecutive patients suffering from proven choledocholithiasis who underwent laparoscopic CBD exploration through a choledochotomy between January 1999 and January 2003. In the early period a T tube was placed at the end of the procedure (n = 32). Biliary stent placement and primary CBD closure was performed from June 2001 (n = 21). There were no significant differences in epidemiological characteristics, preoperative factors or intraoperative findings between the groups. Seven patients developed complications, six in the T tube group and one in the stent group. Univariate analysis revealed a significantly lower morbidity rate and shorter postoperative hospital stay in the stent group. Placement of a biliary endoprosthesis after laparoscopic choledochotomy achieves biliary decompression, and avoids the complications of a T tube, leading to a shorter postoperative hospital stay. The method is a safe and effective alternative method of CBD drainage after laparoscopic choledochotomy. Copyright 2004 British Journal of Surgery Society Ltd. Published by John Wiley & Sons, Ltd.

  19. Ureteric stent placement with extraction string: no strings attached?

    Science.gov (United States)

    Bockholt, Nathan A; Wild, Trevor T; Gupta, Amit; Tracy, Chad R

    2012-12-01

    Study Type--Therapy (case series) Level of Evidence 4 What's known on the subject? and What does the study add? Of patients treated with an indwelling ureteric stent 80-90% experience lower urinary tract symptoms that are a hindrance to health-related quality of life. The prevalence of the extraction/retrieval string after ureteroscopy for stone disease and stent placement varies significantly between surgeons and published series, but the benefits of eliminating the need for a secondary procedure such as cystoscopy and stent removal, as well as the decrease in cost to the patient are well established. Published reports have not addressed the prevalence of post-procedure related events (PREs) in patients who have received an indwelling ureteric stent with the extraction/retrieval string still intact after ureteroscopy for stone disease. By analysing PREs (Emergency Room visits, unscheduled clinic visits, and telephone calls) related to their stent or procedure for patients with and without an extraction/retrieval string, the feasibility of the extraction string can be validated and the misconceptions about their use can be alleviated. • To review a retrospective ureteric stent cohort with and without extraction string to compare post-procedure related events (PRE), as ureteric stent placement after endoscopic management of urolithiasis is common, but data regarding the potential benefits or disadvantages of ureteric stent placement with extraction string are sparse. • Between June 2009 and June 2010, 293 patients underwent ureteroscopy with or without lithotripsy for stone disease. • In all, 181 patients had a unilateral procedure and underwent stent placement postoperatively. • Records were retrospectively reviewed for operative data and PRE occurring within the first 6 weeks after surgery, defined as unscheduled clinic or Emergency Room visits, or adverse event telephone calls. • Of 181 patients who underwent ureteric stent placement, 43 (23

  20. A Single-Institution Experience with Metallic Ureteral Stents: A Cost-Effective Method of Managing Deficiencies in Ureteral Drainage

    Directory of Open Access Journals (Sweden)

    Adam S. Baumgarten

    2014-04-01

    Full Text Available IntroductionThe limitations of traditional ureteral stents in patients with deficiencies in ureteral drainage have resulted in frequent stent exchanges. The implementation of metallic stents was introduced to improve the patency rates of patients with chronic upper urinary tract obstruction, obviating the need for frequent stent exchanges. We report our clinical experiences with the use of metallic ureteral stents in the management of poor ureteral drainage.Materials and MethodsFifty patients underwent metallic ureteral stent placement from 2009 to 2012. Stent failure was defined as an unplanned stent exchange, need for nephrostomy tube placement, increasing hydronephrosis with stent in place, or an elevation in serum creatinine. Stent life was analyzed using the Kaplan-Meier methodology, as this was a time dependent continuous variable. A cost analysis was similarly conducted.ResultsA total of 97 metallic stents were placed among our cohort of patients: 63 in cases of malignant obstruction, 33 in the setting of cutaneous ureterostomies, and 1 in an ileal conduit urinary diversion. Overall, stent failure occurred in 8.2% of the stents placed. Median stent life was 288.4 days (95% CI: 277.4-321.2 days. The estimated annual cost for traditional polymer stents (exchanged every 90 days was $9,648-$13,128, while the estimated cost for metallic stents was $4,211-$5,313.ConclusionOur results indicate that metallic ureteral stent placement is a technically feasible procedure with minimal complications and is well tolerated among patients. Metallic stents can be left in situ for longer durations and provide a significant financial benefit when compared to traditional polymer stents.

  1. Perivascular Inflammatory Reaction After Percutaneous Placement of Covered Stents

    International Nuclear Information System (INIS)

    Link, Johann; Mueller-Huelsbeck, Stefan; Brossmann, Joachim; Steffens, Johann C.; Heller, Martin

    1996-01-01

    A 52-year-old woman with an extensive superficial femoral artery occlusion was treated with percutaneous transluminal angioplasty. Because of extensive dissections, two covered stents were placed percutaneously. The intervention was successful with respect to vessel patency, but local pain and fever developed 5 hr after the intervention. Swelling of the thigh occurred, but deep venous thrombosis was excluded. MRI revealed pronounced soft-tissue edema in the adductor canal that persisted for 4 weeks. The fever responded to antiinflammatory medication, but the pain remained for 4 weeks. The vessel was patent at the last follow-up, 8 weeks after graft placement. Soft-tissue edema after percutaneous placement of covered stents has been reported previously. The cause of the inflammatory reaction is unclear

  2. Use of guiding sheaths in peroral fluoroscopic gastroduodenal stent placement

    International Nuclear Information System (INIS)

    Bae, Jae-Ik; Shin, Ji Hoon; Song, Ho-Young; Yoon, Chang Jin; Nam, Deok Ho; Choi, Won-Chan; Lim, Jin-Oh

    2005-01-01

    Our purpose was to assess the safety and usefulness of guiding sheaths in peroral fluoroscopic gastroduodenal stent placement. Two types of guiding sheath were made from straight polytetrafluoroethylene tubes. Type A was 80 cm in length, 4 mm in outer diameter and 3 mm in inner diameter. Type B was 70 cm in length, 6 mm in outer diameter and 5 mm in inner diameter. The type A sheath was used in 18 patients in whom a catheter-guide wire combination failed to pass through a stricture. The type B sheath was used in 22 patients in whom a stent delivery system failed to pass through the stricture due to loop formation within the gastric lumen. The overall success rate for guiding a catheter-guide wire through a stricture after using the type A sheath was 89%. The overall success rate for passing a stent delivery system through a stricture after using the type B sheath was 100%. All procedures were tolerated by the patients without any significant complications. The guiding sheaths were safe and useful in peroral fluoroscopic gastroduodenal stent placement. (orig.)

  3. Temporary metal stents in bladder outflow obstruction.

    Science.gov (United States)

    Yachia, D

    1997-12-01

    The use of stents in the management of prostatic obstruction started in 1980 with the development of the "partial catheter" by Fabian in Germany. Since then, a variety of metals and biostable and biodegradable polymers have been made into temporary or permanent stents for the management of infravesical obstructions such as benign or malignant prostatic enlargement, bladder neck stenoses, or urethral strictures. This paper is an overview of two generations of temporary metal stents used in the patients with infravesical obstruction.

  4. Usefulness of multifunctional gastrointestinal coil catheter for colorectal stent placement

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae-Hyung; Shin, Ji Hoon; Kim, Jin Hyoung; Lim, Jin-Oh; Kim, Kyung Rae [Asan Medical Center, Radiology and Research Institute of Radiology, Seoul (Korea); Song, Ho-Young [Asan Medical Center - Radiology, Songpa-gu, Seoul (Korea); Park, In Kook [Dongguk University, Life Science, Seoul (Korea); Choi, Eugene K. [Weill Medical College of Cornell University, New York, NY (United States)

    2008-11-15

    The purpose of this study was to evaluate the usefulness of a multifunctional gastrointestinal coil catheter for stent placement in 98 patients with colorectal strictures. The catheter was used in 98 consecutive patients for stent placement in the rectum (n = 24), recto-sigmoid (n = 13), sigmoid (n = 38), descending (n = 6), transverse (n = 11), splenic flexure (n = 3), hepatic flexure (n = 2), and ascending (n = 1) colon. The catheter was made of a stainless steel coil (1.3 mm in inner diameter), a 0.4-mm nitinol wire, a polyolefin tube, and a hemostasis valve. Usefulness of the catheter was evaluated depending on whether the catheter could pass a stricture over a guide wire and whether measurement of the stricture length was possible. The passage of the catheter over a guide wire beyond the stricture was technically successful and well tolerated in 93 (94.9%) of 98 patients. In the failed five patients, it was not possible to negotiate the guide wire due to presence of nearly complete small bowel obstruction. The average length of stricture was 6.15 cm (range, 3 cm to 20 cm) in patients with the colorectal stricture. There were no procedure-related complications. In conclusion, the multifunctional coil catheter seems to be useful in colorectal stent placement. (orig.)

  5. Outcomes after coronary stent implantation in patients with metal allergy.

    Science.gov (United States)

    Romero-Brufau, Santiago; Best, Patricia J M; Holmes, David R; Mathew, Verghese; Davis, Mark D P; Sandhu, Gurpreet S; Lennon, Ryan J; Rihal, Charanjit S; Gulati, Rajiv

    2012-04-01

    Clinical outcomes after stent placement in patients with a history of metal allergy remain incompletely understood. We performed a single-center retrospective study to evaluate such outcomes. Twenty-nine allergic patients who underwent coronary stent implantation were compared with a nonallergic group (n=250) matched for demographics and a propensity score for allergy to metal. Hypersensitivity to nickel was reported in 26 of 29 and chromium in 9 of 29. Patch testing performed in 11 of 29 patients was positive in all. Comparing allergy versus control subjects, there were no differences in number of segments treated (1.4±0.7 versus 1.5±0.7), stents placed (1.7±1.1 versus 1.6±0.9), and frequency of drug-eluting stent usage (52% versus 60%). In-hospital death (0% versus 0%), myocardial infarction (MI, 4% versus 3%, P=0.27), and 30-day death (3% versus 0%, P=0.53) and MI (3% versus 4%, P=0.71) were statistically similar. There were no differences in 4-year death (12% versus 13%), target lesion revascularization (TLR, 13 versus 17%, P=0.54), or death/MI/TLR (24% versus 34%, P=0.20). Clinically driven repeat angiography in 12 of 29 allergy patients revealed binary restenosis rates of 27% in bare metal stents and 0% in drug-eluting stents, with mean diameter in-stent restenosis of 36% and 8%, respectively. There was no change in circulating eosinophil and lymphocyte counts after stenting in the allergy group (0.19-0.20, P=0.67, and 1.90-1.79, P=0.59, respectively). A history of metal allergy was not associated with adverse early or late outcomes in this single-center study.

  6. Safety and benefits of self-expandable metallic stents with chemotherapy for malignant gastric outlet obstruction.

    Science.gov (United States)

    Miyabe, Katsuyuki; Hayashi, Kazuki; Nakazawa, Takahiro; Sano, Hitoshi; Yamada, Tomonori; Takada, Hiroki; Naitoh, Itaru; Shimizu, Shuya; Kondo, Hiromu; Nishi, Yuji; Yoshida, Michihiro; Umemura, Shuichiro; Hori, Yasuki; Kato, Akihisa; Ohara, Hirotaka; Joh, Takashi

    2015-07-01

    The influence of chemotherapy on placement of self-expandable metallic stents (SEMS) for malignant gastric outlet obstruction (MGOO) has not been evaluated extensively. We investigated the influence of chemotherapy on the clinical outcomes of SEMS placement for MGOO. A total of 152 cancer patients with MGOO from a university hospital and affiliate hospitals were included. The patients were classified according to chemotherapy status and evaluated for palliative efficacy and safety of SEMS placement. Technical success rate, time to oral intake, and parameters indicating improvement of physical condition did not differ between the with- and without-chemotherapy groups after stent placement. Re-intervention and stent migration were significantly more frequent in the with-chemotherapy group than in the without-chemotherapy group after stent placement (re-intervention, 32.4% vs 7.8%, P = 0.0005; stent migration, 13.5% vs 1.7%, P = 0.0097). The frequency of adverse events did not differ between the with- and without-chemotherapy groups. Although chemotherapy after stent placement was an independent predictive factor for shortening the stent patency period (hazard ratio [HR], 3.10; P = 0.0264), the use of additional stents facilitated uneventful recovery and further prolonged survival time (HR, 0.60; P = 0.0132). Various cancer patients with MGOO can undergo SEMS placement safely regardless of chemotherapy, and concurrent chemotherapy after stent placement can prolong survival time, although re-intervention and stent migration may be increased. © 2015 The Authors. Digestive Endoscopy © 2015 Japan Gastroenterological Endoscopy Society.

  7. Temporary metal internal stent dilation for colorectal obstruction and effect on operation methods

    International Nuclear Information System (INIS)

    Chen Niwei; Cheng Yingsheng; Fan Youben; Jin Huimin; Xu Huimin

    2005-01-01

    Objective: To explore the methods and clinical value of temporary internal metal stent through endoscopy under X ray control for treating patients with malignant colorectal obstruction. Methods: 27 patients with malignant colorectal obstruction were treated by temporary metallic internal stent placement via endoscopy under the X ray guidance. Results: 27 patients with colorectal obstruction symptoms were all got rid of the trouble within 48 hours after the stent placement. Selective stage I colorectal cancer resection and anastomosis were performed after bowel preparation. Conclusions: Metallic internal stent placement can loosen the colorectal obstructive symptoms with higher successful rate via endoscopy under X ray control and furthermore for promotion of stage I colorectal cancer resection and anastomosis. (authors)

  8. Quality of life after palliative treatment for oesophageal carcinoma -- a prospective comparison between stent placement and single dose brachytherapy

    NARCIS (Netherlands)

    Homs, Marjolein Y. V.; Essink-Bot, Marie-Louise; Borsboom, Gerard J. J. M.; Steyerberg, Ewout W.; Siersema, Peter D.

    2004-01-01

    Metal stent placement and single dose brachytherapy are commonly used treatment modalities for the palliation of inoperable oesophageal carcinoma. We investigated generic and disease-specific health-related quality of life (HRQoL) after these palliative treatments. Patients with dysphagia from

  9. Efficacy of retrievable metallic stent with fixation string for benign stricture after upper gastrointestinal surgery

    Energy Technology Data Exchange (ETDEWEB)

    KIm, Jeong Eun; KIm, Hyo Cheol; Lee, Myung Su; Hur, Sae Beom; KIm, Minuk; Lee, Sang Hwan; Cho, Soo Buem; KIm, Chan Sun; Han, Joon Koo [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2016-11-15

    To determine the efficacy of retrievable metallic stent with fixation string for benign anastomotic stricture after upper gastrointestinal (UGI) surgery. From June 2009 to May 2015, a total of 56 retrievable metallic stents with fixation string were placed under fluoroscopy guidance in 42 patients who were diagnosed with benign anastomotic stricture after UGI surgery. Clinical success was defined as achieving normal regular diet (NRD). The clinical success rate after the first stent placement was 57.1% (24/42). After repeated stent placement and/or balloon dilation, the clinical success rate was increased to 83.3% (35/42). Six (14.3%) patients required surgical revision to achieve NRD. One (2.4%) patient failed to achieve NRD. Stent migration occurred in 60.7% (34/56) of patients. Successful rate of removing the stent using fixation string and angiocatheter was 94.6% (53/56). Distal migration occurred in 12 stents. Of the 12 stents, 10 (83.3%) were successfully removed whereas 2 could not be removed. No complication occurred regarding distal migration. Using retrievable metallic stent with a fixation string is a feasible option for managing early benign anastomotic stricture after UGI surgery. It can reduce complications caused by distal migration of the stent.

  10. Stent placement under fluoroscopic monitoring and endoscopic direct vision for the treatment of malignant gastroduodenal obstruction: a report of 47 cases

    International Nuclear Information System (INIS)

    Zhang Baoyang; Li Weiping; Jiang Haosheng; Liu Shiyi; Hu Yi

    2009-01-01

    Objective: To discuss the operational technique and clinical effect of metallic stent placement in treating malignant gastroduodenal obstruction. Methods: Metallic stent placement under fluoroscopic monitoring and endoscopic direct vision was performed in 47 patients with malignant gastroduodenal obstruction. A total of 54 metallic stents was used. Results: The procedure was successfully completed in all 47 patients. During the follow-up period, all the patients could take liquid or ordinary diet and were markedly relived of vomiting. The living quality was much improved and no serious complications occurred. Conclusion: Under fluoroscopic monitoring and endoscopic direct vision, stent placement is a safe, effective, technically-simple and time-saving procedure for the treatment of malignant gastroduodenal obstruction with less sufferings to the patient. Therefore, it is definitely worth popularizing this technique in clinical practice. (authors)

  11. Surgical gastrojejunostomy or endoscopic stent placement for the palliation of malignant gastric outlet obstruction (SUSTENT study): a multicenter randomized trial

    NARCIS (Netherlands)

    Jeurnink, Suzanne M.; Steyerberg, Ewout W.; van Hooft, Jeanin E.; van Eijck, Casper H. J.; Schwartz, Matthijs P.; Vleggaar, Frank P.; Kuipers, Ernst J.; Siersema, Peter D.; Jeurnink, S. M.; Kuipers, E. J.; Siersema, P. D.; Steyerberg, E. W.; Polinder, S.; Borsboom, G.; van Eijck, C. H. J.; Fockens, P.; Gouma, D. J.; Schwartz, M. P.; Vermeijden, J. R.; van Ooijen, B.; Vleggaar, F. P.; Borel Rinkes, I. H. M.; Grubben, M.; van Laarhoven, C. H. J. M.; Peters, F. T. M.; Porte, R. J.; Plukker, J. Th M.; van Spreeuwel, J. P.; Jakimowicz, J. J.; Boot, H.; Cats, A.; van Coevorden, F. V.; Klaase, J. M.; van der Waaij, L. A.; Baas, P.; van der Schaar, P.; Sosef, M. N.; Timmer, R.; van Ramshorts, B.; Nicolai, J. J.; Houben, M. H. M. G.; Steup, W. H.; Pahlplatz, P. V. M.; Brouwers, M. A. M.; Meijssen, M. A. C.; Marinelli, A.; van der Linde, K.; Manusama, E.; ter Borg, F.; Eeftinck Schattenkerk, M.; Witteman, B.; Kruyt, F.; ten Hove, R.; Schmitz, R. F.; Lesterhuis, W.; Oostenbroek, R.; Veenendaal, R.; Hartgrink, H. H.; Tollenaar, R. A. E. M.; Wahab, P.; Spillenaar Bilgen, E. J.

    2010-01-01

    BACKGROUND: Both gastrojejunostomy (GJJ) and stent placement are commonly used palliative treatments of obstructive symptoms caused by malignant gastric outlet obstruction (GOO). OBJECTIVE: Compare GJJ and stent placement. DESIGN: Multicenter, randomized trial. SETTING: Twenty-one centers in The

  12. Self-expandable metallic stents for patients with recurrent esophageal carcinoma after failure of primary chemoradiotherapy

    International Nuclear Information System (INIS)

    Muto, Manabu; Ohtsu, Atsushi; Boku, Narikazu; Yoshida, Shigeaki; Miyata, Yoshinori; Shioyama, Yasukazu

    2001-01-01

    Recent advances in chemoradiotherapy for esophageal carcinoma have resulted in improved survival rates. However, there are few options for recurrent dysphagia due to refractory carcinoma after failure of primary chemoradiotherapy. The aim of this study was to evaluate the safety and efficacy of self-expandable metallic stent placement for patients with recurrent esophageal carcinoma where definitive chemoradiotherapy has failed. Thirteen consecutive patients with recurrent squamous cell carcinoma of the esophagus, in whom self-expandable metallic stents were placed after failure of primary chemoradiotherapy, were studied retrospectively. All patients had esophageal obstruction or malignant fistula. The oral alimentation status of nine of 13 patients (69%) improved after successful placement of the stent. Following placement of the stent, fever (>38 deg C) and severe chest pain occurred in 85% (11/13) of the patients. In all patients examined, C-reactive protein was elevated within 1 week of the operation. Esophageal perforation occurred in three patients. Stent-related mediastinitis and pneumonia developed in six (46%) and three (23%) patients, respectively. Seven of the 13 patients (54%) died of stent-related pulmonary complications. Although the placement of a self-expandable metallic stent for patients with recurrent esophageal carcinoma after failure of chemoradiotherapy improved their oral alimentation status, we found that this treatment increases the risk of life-threatening pulmonary complications. (author)

  13. [Metallic ureteral stents. Present and future.

    Science.gov (United States)

    Morcillo, E; Fernández, I; Pamplona, M; Sánchez-Margallo, F M; Soria, F

    2016-10-01

    The management of ureteral obstruction of malignant origin or complicated benign obstruction continues to be a challenge for the urological community. In this sense, the use of metallic stents could be considered a useful alternative to the conventional drainage techniques, because it accomplishes the resolution of obstruction in a single procedure, without external diversions and without the adverse effects of current diversions. Another important advantage they offer is that they do not need replacement as frequently as double J catheters or nephrostomy tubes require. From their first applications in the upper urinary tract until now the design of metallic stents has experienced a notable evolution. The main obstacle at the beginning was the use of stents intended for other organic territories, which caused a high rate of failures, since they did not take into consideration in their designs the hostile environment represented by urine for this type of devices, neither the existence of ureteral peristaltism. Thanks to subsequent metallic designs (Memokath, Uventa, Allium Medical URS-stent, Resonance), the current generation of ureteral metallic stents has improved the success rate in comparison to classical designs, accommodating to ureteral dynamics and improving the coating and alloys. Despite these advances, today, their application is limited to very selected patients due to the onset of undesirable effects still associated with theses stents, such as obstructive urothelial hyperplasia, encrustation or migration. The precise knowledge of the physiopathological mechanisms responsible for the cited adverse effects, together with the application of Bioengineering enabling the development of drug eluting metallic stents, biocoated stents, or new biodegradable metallic materials that mitigate or diminish their effects, may be the key to allow the development of the ideal metallic stent.

  14. Functional effects of renal artery stent placement on treated and contralateral kidneys.

    NARCIS (Netherlands)

    Leertouwer, T.C.; Derkx, F.H.M.; Pattynama, P.M.; Deinum, J.; Dijk, L.C. van; Schalekamp, M.A.D.H.

    2002-01-01

    BACKGROUND: This study examined the effects of stent placement for renal artery stenosis on the function of treated and contralateral kidneys. METHODS: Eighteen patients who underwent stent placement for unilateral renal artery stenosis presenting with hypertension and/or renal failure were studied

  15. Intravascular ultrasound assessed incomplete stent apposition and stent fracture in stent thrombosis after bare metal versus drug-eluting stent treatment the Nordic Intravascular Ultrasound Study (NIVUS)

    DEFF Research Database (Denmark)

    Kosonen, Petteri; Vikman, Saila; Jensen, Lisette Okkels

    2013-01-01

    This prospective multicenter registry used intravascular ultrasound (IVUS) in patients with definite stent thrombosis (ST) to compare rates of incomplete stent apposition (ISA), stent fracture and stent expansion in patients treated with drug-eluting (DES) versus bare metal (BMS) stents. ST...

  16. Endoscopic self-expandable metallic stenting for palliation of malignant gastric outlet obstruction in Southeast Asia.

    Science.gov (United States)

    Lye, Tiffany Jian Ying; Goh, Yaw Chong; Eng, Alvin Kim Hock; Ong, Hock Soo; Wong, Wai Keong; Chan, Weng Hoong

    2016-06-01

    Malignant gastric outlet obstruction (GOO) is a pre-terminal event in the natural history of gastric and pancreaticobiliary cancers. The use of endoscopic placement of self-expandable metallic stents (SEMS) is a less invasive alternative palliative option for these patients. This is the first study in Southeast Asia to evaluate the clinical efficacy and safety of endoscopic SEMS placement in patients with malignant GOO. A retrospective review of our department's database in endoscopic SEMS placement for the treatment of malignant GOO was performed. Twenty-four patients with advanced or metastatic malignancy that underwent placement of SEMS for treatment of malignant GOO between January 2003 and July 2013 were analysed. The GOO severity score was used as an objective means of assessing patients' oral intake. Technical success rate was 100%. All patients resumed oral intake of liquids within the same day of stent placement. Clinical success was achieved in 21 patients (87.5%). There was a significant improvement of GOO severity score from 0.62 ± 1.0 (mean ± standard deviation) before stent placement to 2.04 ± 0.86 after stent placement (P < 0.001). Complication rate was 12.5%. Stent-related complications observed include stent migration (two patients) and tumour ingrowth (one patient). Serious complications such as gastrointestinal haemorrhage or perforation did not occur in any patients. The median survival after stent placement was 57 days (95% confidence interval, 12.2-101.8 days). None of the patients died from stent-related complications. Endoscopic SEMS placement is a minimally invasive, safe and effective option for the palliation of malignant GOO. © 2014 Royal Australasian College of Surgeons.

  17. Retrievable Airway Stent Placement for Stoma Stricture after Anterior Mediastinal Tracheostomy: Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jae Yeon; Shin, Ji Hoon; Kim, Yong Hee; Song, Ho Young; Kim, Jin Hyoung [Dept. of University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Lee, Yeoun Joo [Dept. of Pediatrics, Pusan National University Children' s Hospital, Yangsan (Korea, Republic of)

    2013-06-15

    Anterior mediastinal tracheostomy (AMT) is performed to establish an airway after resection of advanced tumors in the cervicothoracic region. We report a case of successful placement of a covered retrievable self-expandable nitinol stent for a stoma stricture that developed after AMT in a patient with adenoid cystic carcinoma of the trachea. Two stent placements and removals, at two and three months after their initial placement, were performed due to loosening of the stents. Although we did not achieve long-term results as the patient died of massive hemorrhage, the stent placement was both feasible and safe, thus suggesting that temporary stent placement may be a valuable option for treating stoma stricture occurring after AMT.

  18. Retrievable Airway Stent Placement for Stoma Stricture after Anterior Mediastinal Tracheostomy: Case Report

    International Nuclear Information System (INIS)

    Hwang, Jae Yeon; Shin, Ji Hoon; Kim, Yong Hee; Song, Ho Young; Kim, Jin Hyoung; Lee, Yeoun Joo

    2013-01-01

    Anterior mediastinal tracheostomy (AMT) is performed to establish an airway after resection of advanced tumors in the cervicothoracic region. We report a case of successful placement of a covered retrievable self-expandable nitinol stent for a stoma stricture that developed after AMT in a patient with adenoid cystic carcinoma of the trachea. Two stent placements and removals, at two and three months after their initial placement, were performed due to loosening of the stents. Although we did not achieve long-term results as the patient died of massive hemorrhage, the stent placement was both feasible and safe, thus suggesting that temporary stent placement may be a valuable option for treating stoma stricture occurring after AMT.

  19. The Efficacy of the Coaxial Technique Using a 6-Fr Introducer Sheath in Stent Placement for Treating the Obstructions Proximal to the Descending Colon

    International Nuclear Information System (INIS)

    Chang, Il Soo; Park, Sang Woo; Hwang, Dae Yong; Seong, Moo Kyung; Joh, Hee Kyung; Yoon, So Young; Cho, Yo Han; Choe, Won Hyeok

    2011-01-01

    We wanted to evaluate the efficacy of stent placement using the coaxial technique with a stiff, long introducer sheath in patients with technical failure using an angiographic catheter for the obstructions proximal to the descending colon. Self-expandable metallic stent placement was attempted under fluoroscopy-guidance in 77 consecutive patients who had malignant colorectal obstruction. Stent placement was performed using an angiographic catheter and a guide wire. If the angiographic catheter could not be advanced over the guide wire into the obstructive lesions proximal to the descending colon, then a 6-Fr introducer sheath was used. The technical success rate, the clinical success rate and the complications were analyzed. Successful stent placement was achieved in 75 of 77 patients (97%). The angiographic catheter failed to advance into the obstructive lesions of 11 patients (M:F = 7:4: mean age, 65.5 years) whose lesions were at the level of the splenic flexure or transverse colon. Therefore, the coaxial technique was implemented in all these 11 patients using a 6-Fr stiff introducer sheath and then the stent placement was successful. There were no complications related to the use of a stiff introducer sheath. Clinical success, which was defined as relief of clinical obstructive bowel symptoms, was obtained within 24 hours in all of patients. The coaxial technique using a stiff introducer sheath can increase the technical success of fluoroscopy-guided, self-expandable metallic stent placement in patients with colonic obstruction proximal to the descending colon

  20. Clinical outcomes of self-expandable metal stent (SEMS placement as palliative treatment for malignant colorectal obstruction: A single-center study from Japan

    Directory of Open Access Journals (Sweden)

    Toshikatsu Nitta

    2017-07-01

    Conclusion: SEMS placement as a palliative treatment is likely to fail within a year, leading to re-occlusion. It is very important to maintain vigilant monitoring using X-ray, CT, and colonoscopy after SEMS placement, with close cooperation between the endoscopist and surgeon. A logistic framework involving careful follow-up, even in the absence of symptoms, and a combined team involving endoscopists and surgeons should be established to support re-intervention and surgery. We recommend vigilant monitoring of patients who received SEMS placement for palliation of malignant colorectal obstruction.

  1. Percutaneous transcholecystic approach for an experiment of biliary stent placement: an experimental study in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Tae Seok [Medical School of Gachon, Inchon (Korea, Republic of); Song, Ho Young; Lim, Jin Oh; Ko, Gi Young; Sung, Kyu Bo; Kim, Tae Hyung; Lee, Ho Jung [College of Medicine, Ulsan Univ., Seoul (Korea, Republic of)

    2002-06-01

    To determine, in an experimental study of biliary stent placement, the usefulness and safety of the percutaneous transcholecystic approach and the patency of a newly designed biliary stent. A stent made of 0.15-mm-thick nitinol wire, and 10 mm in diameter and 2 cm in length, was loaded in an introducer with an 8-F outer diameter. The gallbladders of seven mongrel dogs were punctured with a 16-G angiocath needle under sonographic guidance, and cholangiography was performed. After anchoring the anterior wall of the gallbladder to the abdominal wall using a T-fastener, the gallbladder body was punctured again under fluoroscopic guidance. The cystic and common bile ducts were selected using a 0.035-inch guide wire and a cobra catheter, and the stent was placed in the common bile duct. Post-stenting cholangiography was undertaken, and an 8.5-F drainage tube was inserted in the gallbladder. Two dogs were followed-up and sacrificed at 2,4 and 8 weeks after stent placement, respectively, and the other expired 2 days after stent placement. Follow-up cholangiograms were obtained before aninmal was sacrified, and a pathologic examination was performed. Stent placement was technically successful in all cases. One dog expired 2 days after placement because of bile peritonitis due to migration of the drainage tube into the peritoneal cavity, but the other six remained healthy during the follow-up period. Cholangiography performed before the sacrifice of each dog showed that the stents were patent. Pathologic examination revealed the proliferation of granulation tissue at 2 weeks, and complete endothelialization over the stents by granulation tissue at 8 weeks. Percutaneous transcholecystic biliary stent placement appears to be safe, easy and useful. After placement, the stent was patent during the follow-period.

  2. Percutaneous transcholecystic approach for an experiment of biliary stent placement: an experimental study in dogs

    International Nuclear Information System (INIS)

    Seo, Tae Seok; Song, Ho Young; Lim, Jin Oh; Ko, Gi Young; Sung, Kyu Bo; Kim, Tae Hyung; Lee, Ho Jung

    2002-01-01

    To determine, in an experimental study of biliary stent placement, the usefulness and safety of the percutaneous transcholecystic approach and the patency of a newly designed biliary stent. A stent made of 0.15-mm-thick nitinol wire, and 10 mm in diameter and 2 cm in length, was loaded in an introducer with an 8-F outer diameter. The gallbladders of seven mongrel dogs were punctured with a 16-G angiocath needle under sonographic guidance, and cholangiography was performed. After anchoring the anterior wall of the gallbladder to the abdominal wall using a T-fastener, the gallbladder body was punctured again under fluoroscopic guidance. The cystic and common bile ducts were selected using a 0.035-inch guide wire and a cobra catheter, and the stent was placed in the common bile duct. Post-stenting cholangiography was undertaken, and an 8.5-F drainage tube was inserted in the gallbladder. Two dogs were followed-up and sacrificed at 2,4 and 8 weeks after stent placement, respectively, and the other expired 2 days after stent placement. Follow-up cholangiograms were obtained before aninmal was sacrified, and a pathologic examination was performed. Stent placement was technically successful in all cases. One dog expired 2 days after placement because of bile peritonitis due to migration of the drainage tube into the peritoneal cavity, but the other six remained healthy during the follow-up period. Cholangiography performed before the sacrifice of each dog showed that the stents were patent. Pathologic examination revealed the proliferation of granulation tissue at 2 weeks, and complete endothelialization over the stents by granulation tissue at 8 weeks. Percutaneous transcholecystic biliary stent placement appears to be safe, easy and useful. After placement, the stent was patent during the follow-period

  3. Self-expanding metallic stents for gastric outlet obstruction resulting from stomach cancer: a preliminary study with a newly designed double-layered pyloric stent.

    Science.gov (United States)

    Lee, Sun Mi; Kang, Dae Hwan; Kim, Gwang Ha; Park, Won Il; Kim, Hyong Wook; Park, Jin Hong

    2007-12-01

    Although endoscopic stent placement is now generally accepted as a palliative treatment for gastric outlet obstruction resulting from gastric cancer, it carries potential limitations such as tumor ingrowth or migration. Our purpose was to evaluate the technical and clinical efficacy of endoscopic placement of a newly designed double-layered combination pyloric stent. Prospective, uncontrolled, single-center. Tertiary referral university hospital. Eleven patients with gastric outlet obstruction by unresectable stomach cancer. Eleven patients received a double-layered combination pyloric stent (an outer uncovered stent to reduce migration and an inner polytetrafluoroethylene-covered stent to prevent tumor ingrowth). To evaluate technical success, clinical success, and complications, especially tumor ingrowth and migration. Technical success was achieved in 11 of 11 (100%) patients. Among 11 patients in whom endoscopic stenting was placed successfully, clinical success was 90.9%, tumor ingrowth 0%, migration 9.1%, and tumor overgrowth 9.1%. Median stent patency period was 121 days. Small number of patients, uncontrolled study, short-term follow-up period. We have described a technique for endoscopic metal stent placement by using the newly designed double-layered combination stent for gastric outlet obstruction by stomach cancer. This stent seems to be effective and looks promising for technical efficacy, clinical outcome, and preventing tumor ingrowth and migration.

  4. Comparison of Technical and Clinical Outcome of Transjugular Portosystemic Shunt Placement Between a Bare Metal Stent and a PTFE-Stentgraft Device

    Energy Technology Data Exchange (ETDEWEB)

    Lauermann, J., E-mail: jostlauermann@gmail.com [Hannover Medical School, Department of Diagnostic and Interventional Radiology (Germany); Potthoff, A. [Hannover Medical School, Department of Gastroenterology, Hepatology and Endocrinology (Germany); Mc Cavert, M. [Beaumont Hospital, Department of Diagnostic and Interventional Radiology (Ireland); Marquardt, S. [Hannover Medical School, Department of Diagnostic and Interventional Radiology (Germany); Vaske, B. [Hannover Medical School, Institute of Biometry (Germany); Rosenthal, H. [Hannover Medical School, Department of Diagnostic and Interventional Radiology (Germany); Hahn, T. von [Hannover Medical School, Department of Gastroenterology, Hepatology and Endocrinology (Germany); Wacker, F.; Meyer, B. C.; Rodt, Thomas, E-mail: rodt.thomas@mh-hannover.de [Hannover Medical School, Department of Diagnostic and Interventional Radiology (Germany)

    2016-04-15

    PurposeTo analyse technical and clinical success of transjugular intrahepatic portosystemic shunt (TIPS) in patients with portal hypertension and compare a stent and a stentgraft with regard to clinical and technical outcome and associated costs.Materials and Methods170 patients (56 ± 12 years, 32.9 % females) treated with TIPS due to portal hypertension were reviewed. 80 patients received a stent (group 1) and 83 a stentgraft (group 2), and seven interventions were unsuccessful. Technical data, periprocedural imaging, follow-up ultrasound and clinical data were analysed with focus on technical success, patency, clinical outcome and group differences. Cost analysis was performed.ResultsPortal hypertension was mainly caused by ethyltoxic liver cirrhosis with ascites as dominant symptom (80 %). Technical success was 93.5 % with mean portosystemic gradient decrease from 16.1 ± 4.8 to 5.1 ± 2.1 mmHg. No significant differences in technical success and portosystemic gradient decrease between the groups were observed. Kaplan–Meier analysis yielded significant differences in primary patency after 14 days, 6 months and 2 years in favour of the stentgraft. Both groups showed good clinical results without significant difference in 1-year survival and hepatic encephalopathy rate. Costs to establish TIPS and to manage 2-year follow-up with constant patency and clinical success were 8876 € (group 1) and 9394 € (group 2).ConclusionTIPS is a safe and effective procedure to manage portal hypertension. Stent and stentgraft enabled good technical and clinical results with a low complication rate. Primary patency rates are clearly in favour of the stentgraft, whereas the stent was more cost effective with similar clinical results in both groups.

  5. Self-expanding oesophageal metal stents for the palliation of dysphagia due to extrinsic compression

    International Nuclear Information System (INIS)

    Gupta, N.K.; Boylan, C.E.; Razzaq, R.; England, R.E.; Mirra, L.; Martin, D.F.

    1999-01-01

    The role of self-expanding metallic stents is well established in the palliation of oesophageal stenosis and dysphagia due to primary oesophageal malignancy. However, their role in palliation of dysphagia due to external compressive mediastinal malignancies is not well established. The purpose of this study was to assess the efficacy of self-expanding metallic stents in the palliation of dysphagia due to extrinsic oesophageal compression by mediastinal malignancy. Between January 1995 and January 1998, 21 patients with oesophageal compression due to malignant mediastinal tumours underwent oesophageal stent placement for palliation of dysphagia. Complete data were available in 17 patients (10 men and 7 women). The mean age was 63.5 years (range 46-89 years). A total of 19 stents were placed successfully. The dysphagia grade prior to and after oesophageal stent placement was assessed and the complications documented. Of the 17 patients, 16 reported an improvement in dysphagia. The mean dysphagia score improved from 3.1 prior to treatment to 1.3 after treatment. In 1 patient the stent slipped during placement and another stent was placed satisfactorily. Early complications (within 48 h) in the form of mild to moderate retrosternal chest pain occurred in 5 patients. This was treated symptomatically. Late complications (after 48 h) in the form of bolus impaction occurred in 2 patients. This was successfully treated with oesophagoscopy and removal of bolus. In 2 patients the stent was overgrown by tumour and in one of these an additional stent was placed. In 1 patient incomplete closure of a tracheo-oesophageal fistula was observed. There was no procedure- or stent-related mortality. The mean survival time of this group was 2.1 months. Self-expanding metallic stents can be safely and effectively used in the palliation of dysphagia due to external mediastinal malignancies. (orig.)

  6. Delayed colonic perforation following stent placement for colorectal obstruction: a description of two cases with stent palliation.

    Directory of Open Access Journals (Sweden)

    Jalal Vahedian Ardakani

    2013-10-01

    Full Text Available Bowel stent insertion has a variety of complications one major of which is colonic perforation. The purpose of this article is to reveal two cases with delayed colonic perforation after stent placement to relieve bowel obstruction caused by rectal cancer. The first patient was a 55 year-old man who was a candidate for stent placement to avoid palliative surgery and relieve his bowel obstruction. Although the procedure resulted in complete relief of patient symptoms, but he returned with signs of peritonitis 10 days after the stent placement. A perforation was found at rectosigmoid junction on laparotomy. The second patient was a 60 year-old man who underwent a successful stent placement and returned 3 months later with a complaint of abdominal pain that showed up to be due to a rectal perforation on investigations. In conclusion, bowel perforation following stent placement can be a major complication, so close follow-up is necessary to detect it as soon as possible and prevent it from becoming an irreparable complication.

  7. Clinical application of self-expandable metallic stents in the treatment of malignant tracheal stenosis under general anesthesia

    International Nuclear Information System (INIS)

    Wang Weitao; Shi Haibin; Yang Zhengqiang; Liu Sheng; Zhou Chungao; Zhao Linbo; Xia Jinguo; Li Linsun

    2009-01-01

    Objective: To evaluate the safety and efficacy of self-expandable metallic stent placement for the treatment of malignant tracheal stenosis under general anesthesia and fluoroscopic guidance. Methods: Under general anesthesia the placement of self-expandable metallic stent was performed in 10 patients with malignant tracheal stenosis, the procedure was completed under fluoroscopic guidance in all patients. Results: Successful tracheal stenting was achieved in all 10 patients. In one patient, a Y-shaped stent was used as the tracheal carina was involved in the airway stenosis. The symptoms of dyspnea and asthma were markedly improved immediately after the implantation of stent in all patients. Conclusion: Tracheal implantation of self-expandable metallic stent under general anesthesia and fluoroscopic guidance is a safe and effective treatment for malignant tracheal stenosis, it can promptly relieve various symptoms caused by malignant tracheal stenosis and obviously improve patient's living quality, therefore,t his technique is of great value in clinical practice. (authors)

  8. Brachytherapy for the prevention of neointimal hyperplasia in the canine inferior vena cava after stent placement

    Energy Technology Data Exchange (ETDEWEB)

    Isota, Masayuki; Kaminou, Toshio; Sakai, Yukimasa; Nakamura, Kenji; Yamada, Ryusaku [Osaka City Univ. (Japan). Medical School

    2002-06-01

    The aim of this study was to evaluate the efficacy of brachytherapy for preventing neointimal hyperplasia in the inferior vena cava (IVC) after stent placement. Sixteen beagles underwent Z-stent placement in the IVC and the aorta. For 8 of 16 beagles, irradiation (15 Gy) was delivered endoluminally to the stented segments of each vessel immediately after stent placement using the {sup 192}Ir. All animals were sacrificed after 6 weeks for morphometric and histopathologic examination. Morphometrically, neointimal thickness in the IVC of the radiation group was significantly decreased compared with the control group as well as that in the aorta (p<0.05). Histopathologic findings showed the neointima in the IVC of the control group contained markedly organization of thrombus and neovascularization though that in the IVC of the radiation group consisted mainly of smooth muscle cells without organization of thrombus and neovascularization. From these data intravenous irradiation may prevent clinical restenosis after stent placement. (author)

  9. Renal Transplant Ureteral Stenosis: Treatment by Self-Expanding Metallic Stent

    International Nuclear Information System (INIS)

    Cantasdemir, Murat; Kantarci, Fatih; Numan, Furuzan; Mihmanli, Ismail; Kalender, Betul

    2003-01-01

    We report the use of a metallic stent in a transplant ureteral stenosis. A 28-year-old man with chronic renal failure due to chronic pyelonephritis, who received a living-donor renal transplant, presented with transplant ureteral stenosis. The stenosis was unresponsive to balloon dilation and was treated by antegrade placement of a self-expanding Memotherm stent. The stentedureter stayed patent for 3 years. It may be reasonable to treat post-transplant ureteral stenosis resistant to balloon dilation with self-expanding metallic stents. However, long-term follow-up is required to evaluate the efficacy of this treatment

  10. Percutaneous treatment of superior vena cava syndrome using metallic stents

    International Nuclear Information System (INIS)

    De Gregorio Ariza, Miguel Angel; Gimeno, Maria Jose; Alfonso, Eduardo; Mainar, Antonio; Medrano, Joaquin; Lopez-Marin, Paloma; Gamboa, Pablo; Tobio, Ricardo; Herrera, Marcos

    2003-01-01

    The purpose of this study was to evaluate the results of treatment of superior vena cava syndrome (SVCS) in patients with benign and malignant disease using expandable metallic stent. From January 1995 to April 2000, 87 expandable stents were implanted in 82 patients (59 men, 23 women; mean age 57.8 years, age range 39-79 years) for the treatment of SVCS. The SVCS was defined as symptomatic bilateral obstruction of venous drainage from head, neck and upper extremities. In 68 patients SVCS was due to malignant neoplasia, and in 14 cases it was due to benign aetiology. All patients were treated with expandable stent. We implanted 81 Wallstent prostheses and 6 Palmaz stents. Adjuvant thrombolysis was applied in 12 patients who required fibrinolysis. After recanalization, the stent was implanted in all cases in SVC (infra- or supra-azygos vein). All patients were treated with heparin of low molecular weight (HBPM) during 6 months. Patency was analyzed according to clinical symptoms and Doppler US or venograms exploration. Technical success was observed in all cases. Clinical success was reached in 78 of 82 patients (95.1%) (absence of symptoms in 2 or 3 days). Four patients suffered immediate thrombosis which required fibrinolitic treatment with a new prosthesis placement in 1 case. The follow-up for the malignant process was of 7.1 months (range 1-39 months) and in benign cases was 31.2 months (range 11-61 months). Sixty-two (91.1%) patients with malignancy died without SVCS symptomatology. All the patients with benign pathology are alive. Clinical primary patency in malignant cases was 87% with assisted patency of 96.2%. Endovascular therapy using metallic stent and thrombolysis is a successful method to treat SVCS due to benign or malignant aetiology. (orig.)

  11. Percutaneous treatment of superior vena cava syndrome using metallic stents

    Energy Technology Data Exchange (ETDEWEB)

    De Gregorio Ariza, Miguel Angel; Gimeno, Maria Jose; Alfonso, Eduardo; Mainar, Antonio; Medrano, Joaquin; Lopez-Marin, Paloma [Department of Interventional Radiology, ' ' Lozano Blesa' ' University Hospital, Avda. San Juan Bosco 15, 50009 Zaragoza (Spain); Gamboa, Pablo [Division of Interventional Radiology, Ohio State University Hospital, Columbus, Ohio (United States); Tobio, Ricardo [Interventional Radiology, Clinica de la Zarzuela, Madrid (Spain); Herrera, Marcos [Division of Interventional Radiology, University of Minnesota, Minneapolis, Minnesota (United States)

    2003-04-01

    The purpose of this study was to evaluate the results of treatment of superior vena cava syndrome (SVCS) in patients with benign and malignant disease using expandable metallic stent. From January 1995 to April 2000, 87 expandable stents were implanted in 82 patients (59 men, 23 women; mean age 57.8 years, age range 39-79 years) for the treatment of SVCS. The SVCS was defined as symptomatic bilateral obstruction of venous drainage from head, neck and upper extremities. In 68 patients SVCS was due to malignant neoplasia, and in 14 cases it was due to benign aetiology. All patients were treated with expandable stent. We implanted 81 Wallstent prostheses and 6 Palmaz stents. Adjuvant thrombolysis was applied in 12 patients who required fibrinolysis. After recanalization, the stent was implanted in all cases in SVC (infra- or supra-azygos vein). All patients were treated with heparin of low molecular weight (HBPM) during 6 months. Patency was analyzed according to clinical symptoms and Doppler US or venograms exploration. Technical success was observed in all cases. Clinical success was reached in 78 of 82 patients (95.1%) (absence of symptoms in 2 or 3 days). Four patients suffered immediate thrombosis which required fibrinolitic treatment with a new prosthesis placement in 1 case. The follow-up for the malignant process was of 7.1 months (range 1-39 months) and in benign cases was 31.2 months (range 11-61 months). Sixty-two (91.1%) patients with malignancy died without SVCS symptomatology. All the patients with benign pathology are alive. Clinical primary patency in malignant cases was 87% with assisted patency of 96.2%. Endovascular therapy using metallic stent and thrombolysis is a successful method to treat SVCS due to benign or malignant aetiology. (orig.)

  12. Role of Fully Covered Self-Expandable Metal Stent for Treatment of Benign Biliary Strictures and Bile Leaks

    Energy Technology Data Exchange (ETDEWEB)

    Pausawasadi, Nonthalee [Department of Medicine, Siriraj Hospital, Mahidol University, Bangkok (Thailand); Soontornmanokul, Tanassanee; Rerknimitr, Rungsun [Department of Medicine, Chulalongkorn University, Bangkok (Thailand)

    2012-02-15

    Endoscopic therapy by balloon dilation and placement of multiple large-bore plastic stents is the treatment of choice for benign biliary stricture. This approach is effective but it typically requires multiple endoscopic sessions given the short duration of stent patency. The endoscopic approach for treatment of bile leak involves the placement of a stent with or without biliary sphincterotomy. The self-expandable metal stent (SEMS) has traditionally been used for palliation of malignant biliary strictures given the long duration of stent patency owing to their larger stent diameter. Recently, SEMS has been used in a variety of benign biliary strictures and leaks, especially with the design of the covered self-expandable metal stent (CSEMS), which permits endoscopic-mediated stent removal. The use of CSEMS in benign biliary stricture could potentially result in a decrease in endoscopic sessions and it is technically easier when compared to placement of multiple plastic stents. However, complications such as cholecystitis due to blockage of cystic duct, stent migration, infection and pancreatitis have been reported. The potential subsegmental occlusion of contralateral intrahepatic ducts also limits the use of CSEMS in hilar stricture. Certain techniques and improvement of stent design may overcome these challenges in the future. Thus, CSEMS may be appropriate in only highly selected conditions, such as refractory benign biliary stricture, despite multiple plastic stent placement or difficult to treat bile duct stricture from chronic pancreatitis, and should not be used routinely. This review focuses on the use of fully covered self-expandable metal stent for benign biliary strictures and bile leaks.

  13. Role of Fully Covered Self-Expandable Metal Stent for Treatment of Benign Biliary Strictures and Bile Leaks

    International Nuclear Information System (INIS)

    Pausawasadi, Nonthalee; Soontornmanokul, Tanassanee; Rerknimitr, Rungsun

    2012-01-01

    Endoscopic therapy by balloon dilation and placement of multiple large-bore plastic stents is the treatment of choice for benign biliary stricture. This approach is effective but it typically requires multiple endoscopic sessions given the short duration of stent patency. The endoscopic approach for treatment of bile leak involves the placement of a stent with or without biliary sphincterotomy. The self-expandable metal stent (SEMS) has traditionally been used for palliation of malignant biliary strictures given the long duration of stent patency owing to their larger stent diameter. Recently, SEMS has been used in a variety of benign biliary strictures and leaks, especially with the design of the covered self-expandable metal stent (CSEMS), which permits endoscopic-mediated stent removal. The use of CSEMS in benign biliary stricture could potentially result in a decrease in endoscopic sessions and it is technically easier when compared to placement of multiple plastic stents. However, complications such as cholecystitis due to blockage of cystic duct, stent migration, infection and pancreatitis have been reported. The potential subsegmental occlusion of contralateral intrahepatic ducts also limits the use of CSEMS in hilar stricture. Certain techniques and improvement of stent design may overcome these challenges in the future. Thus, CSEMS may be appropriate in only highly selected conditions, such as refractory benign biliary stricture, despite multiple plastic stent placement or difficult to treat bile duct stricture from chronic pancreatitis, and should not be used routinely. This review focuses on the use of fully covered self-expandable metal stent for benign biliary strictures and bile leaks.

  14. Use of filter device during angioplasty and stent placement for the treatment of carotid stenosis

    International Nuclear Information System (INIS)

    Hong Bo; Liu Jianmin; Xu Yi; Zhao Wenyuan; Huang Qinghai; Zhang Long; Zhang Xin; Xin Tao

    2004-01-01

    Objective: To analyze the effect of filter device in the prevention of cerebral embolic events during carotid angioplasty and stent placement. Methods: Angioguard was used in the treatment of 25 patients of symptomatic carotid artery stenoses by angioplasty and stenting. The filter devices were placed distally to the stenoses and deployed before angioplasty and stent placement. Cerebral thromboembolic events were noted and the filter devices were macroscopically observed. Results: The filter devices were placed and carotid angioplasty and stenting were successfully administered in all 25 patients. Debris could be found macroscopically in 15 out of 25 retrieved filters. There was no death or symptomatic cerebral thromboembolic events during the procedure. Short-term clinical follow-up showed excellent results. Conclusion: Use of filter device may improve the safety of carotid angioplasty and stent placement. (authors)

  15. Biolimus-eluting stents with biodegradable polymer versus bare-metal stents in acute myocardial infarction

    DEFF Research Database (Denmark)

    Räber, Lorenz; Kelbæk, Henning; Taniwaki, Masanori

    2014-01-01

    BACKGROUND: This study sought to determine whether the 1-year differences in major adverse cardiac event between a stent eluting biolimus from a biodegradable polymer and bare-metal stents (BMSs) in the COMFORTABLE trial (Comparison of Biolimus Eluted From an Erodible Stent Coating With Bare Metal...

  16. Randomised trial of self-expanding metal stents versus polyethylene stents for distal malignant biliary obstruction

    NARCIS (Netherlands)

    Davids, P. H.; Groen, A. K.; Rauws, E. A.; Tytgat, G. N.; Huibregtse, K.

    1992-01-01

    Self-expanding metal stents are claimed to prolong biliary-stent patency, although no formal comparative trial between plastic and expandable stents has been done. In a prospective randomised trial, we assigned 105 patients with irresectable distal bile-duct malignancy to receive either a metal

  17. Factors associated with delayed gastric emptying in patients with stent placement for malignant gastric outlet obstruction

    Science.gov (United States)

    Tominaga, Kenji; Maetani, Iruru; Shigoka, Hiroaki; Omuta, Shigefumi; Sato, Koichiro; Ito, Sayo; Saigusa, Yoshinori; Gomi, Tatsuya; Kohda, Ehiichi

    2013-01-01

    Background and study aims: Delayed gastric emptying (DGE) is an important factor in determining the clinical outcome in patients with stent placement for malignant gastric outlet obstruction but the factors associated with DGE remain unclear. The aim of this study was to investigate whether clinicopathologic data could be used to identify the factors for DGE in such patients. Patients and methods: A prospective, single-arm, observational clinical study was performed in a referral hospital in Japan. A total of 54 patients with stent placement for malignant gastric outlet obstruction were enrolled. A gastric emptying scintigraphy test was performed 1 week after stent placement. The relationship between DGE and clinicopathologic factors was investigated, and also the relationship between DGE and stent patency time, eating period (when the patient was able to maintain oral intake), and survival time. Results: A total of 38.9 % (21 /54) of patients had DGE. The following were identified as independent predictive factors of DGE: opioid use (odds ratio, 5.32; 95 % confidence interval [95 %CI], 1.07 – 26.41; p = 0.04), chemotherapy before stent placement (odds ratio, 8.03; 95 %CI, 1.85 – 34.95; p = 0.006), and smaller stent diameter (odds ratio, 13.59; 95 %CI, 1.72 – 107.41; p = 0.01). No relationship was found between DGE and the level of oral intake, stent patency time, eating period, and survival time. Conclusions: The factors associated with DGE after stent placement include those associated with the patient’s tumor as well as factors relating to their treatment, including stenting. The clinical and functional results after stent placement appear to be unrelated to the gastric emptying findings. PMID:26135508

  18. Tracheal stenosis after treatment with metallic stent: a situation worse than the initial problem

    International Nuclear Information System (INIS)

    Barreto, Jaime; Mejia, Bibiana; Nino, Federico; Garavito, Carlos

    2008-01-01

    Stens are a tubular device for use in trachea, carina or main bronchus to provide a support and maintain the permeability of these structures. There are two groups: Metallic and Silicone stent. Either metallic and silicone stents has a special properties. Metallic stent are very attractive option due to relative easy in their placement. The accumulated experience in this therapy has allowed to recognize several complications to take into consideration mainly in patients with tracheal benign stenosis. FDA has recommended don't use metallic stents, covered and not covered in benign diseases. We report a case of a tracheal stenosis secondary to prolonged ortho tracheal intubation that required extensive interventions to control symptoms of central airway obstruction, between April and July of 2005.

  19. Is the Routine Check Nephrostogram Following Percutaneous Antegrade Ureteric Stent Placement Necessary?

    International Nuclear Information System (INIS)

    Soh, Keng Chuan; Tay, Kiang Hiong; Tan, Bien Soo; MM Htoo, Austin; HG Lo, Richard; Lin, Shueh En

    2008-01-01

    Our aim was to review our experience with percutaneous antegrade ureteric stent (PAUS) placement and to determine if the routinely conducted check nephrostogram on the day following ureteric stent placement was necessary. Retrospective review of patients who had undergone PAUS placement between January 2004 and December 2005 was performed. There were 83 subjects (36 males, 47 females), with a mean age of 59.9 years (range, 22-94 years). Average follow-up duration was 7.1 months (range, 1-24 months). The most common indications for PAUS placement were ureteric obstruction due to metastatic disease (n = 56) and urinary calculi (n = 34). Technical success was 93.2% (96/103 attempts), with no major immediate procedure-related complications or mortalities. The Bard 7Fr Urosoft DJ Stent was used in more than 95% of the cases. Eighty-one of 89 (91.0%) check nephrostograms demonstrated a patent ureteric stent with resultant safety catheter removal. Three check nephrostograms revealed distal stent migration requiring repositioning by a goose-snare, while five others showed stent occlusion necessitating permanent external drainage by nephrostomy drainage catheter reinsertion. Following PAUS placement, the serum creatinine level improved or stabilized in 82% of patients. The serum creatinine outcome difference between the groups with benign and malignant indications for PAUS placement was not statistically significant (p = 0.145) but resolution of hydronephrosis was significantly better (p = 0.008) in patients with benign indications. Percutaneous antegrade ureteric stent placement is a safe and effective means of relief for ureteric obstruction. The check nephrostogram following ureteric stent placement was unnecessary in the majority of patients

  20. Sustained relief of obstructive symptoms for the remaining life of patients following placement of an expandable metal stent for malignant colorectal obstruction Mejoría mantenida durante el resto de la vida de los síntomas obstructivos en pacientes con obstrucciones malignas colorrectales trás la colocación de prótesis metálicas expandibles

    Directory of Open Access Journals (Sweden)

    Jorge Manuel Canena

    2012-08-01

    Full Text Available Background: self-expanding metal stents are currently being used as a definitive palliative treatment for malignant colorectal obstruction in patients with incurable disease. Few studies have followed large numbers of patients from stent placement until death, and those few have reported conflicting results in the long-term clinical outcome data. Aims: this study evaluated the clinical effectiveness of stent placement for malignant colorectal obstruction throughout the patients' lives and related factors affecting stent patency, clinical success and complications. Methods: this was a multicentre, retrospective study of 89 consecutive patients who had undergone attempted expandable stent placement for symptomatic malignant colorectal obstruction during a 10-year period. Data were collected to analyse the sustained relief of obstructive symptoms throughout the patients' lives, as well as the technical success, immediate clinical success, stent patency, complications, reinterventions, survival, prognostic factors associated with stent patency and long-term clinical efficacy and risk factors for complications. Results: technical and immediate clinical success were achieved in 95.5% and 91.0% of patients, respectively. A total of 68 out of 89 patients (76.4% maintained relief of obstruction from stent implantation until death without reintervention. Twenty patients (22.5% had complications including perforation (n = 4; 4.5%, stent obstruction (n = 8; 9.0%, migration (n = 5; 5.6% and haemorrhage (n = 3; 3.4%. Stent-related mortality was seen in 1 patient (1.1%. The estimated median survival and estimated mean stent patency were 87.0 and 322.7 days, respectively. In total, 12 of the initial 89 patients (13.5% needed a colostomy for long-term relief of the obstructive symptoms. Univariate and multivariate analysis detected no significant prognostic factors associated with stent patency, long-term clinical efficacy and risk factors for complications

  1. Covered metallic stents with an anti-migration design vs. uncovered stents for the palliation of malignant gastric outlet obstruction: a multicenter, randomized trial.

    Science.gov (United States)

    Lee, Hyuk; Min, Byung-Hoon; Lee, Jeong Hoon; Shin, Cheol Min; Kim, Younjoo; Chung, Hyunsoo; Lee, Sang Hyub

    2015-10-01

    Previous studies reported comparable stent patency between covered self-expandable metallic stents (SEMS) and uncovered SEMS (UCS) for palliation of malignant gastric outlet obstruction (GOO). The aim of this study was to evaluate the efficacy and safety of the newly developed WAVE-covered SEMS (WCS), which has an anti-migration design, compared with UCS in gastric cancer patients with symptomatic GOO. A total of 102 inoperable gastric cancer patients with symptomatic GOO were prospectively enrolled from five referral centers and randomized to undergo UCS or WCS placement. Stent patency and recurrence of obstructive symptoms were assessed at 8 weeks and 16 weeks after stent placement. At the 8-week follow-up, both stent patency rates (72.5% vs. 62.7%) and re-intervention rates (19.6% vs. 19.6%) were comparable between the WCS and the UCS groups. Both stent stenosis (2.4% vs. 8.1%) and migration rates (9.5% vs. 5.4%) were comparable between WCS and UCS groups. At the 16-week follow-up, however, the WCS group had a significantly higher stent patency rate than the UCS group (68.6% vs. 41.2%). Re-intervention rates in the WCS and UCS groups were 23.5% and 39.2%, respectively. Compared with the UCS group, the WCS group had a significantly lower stent restenosis rate (7.1% vs. 37.8%) and a comparable migration rate (9.5% vs. 5.4%). Overall stent patency was significantly longer in the WCS group than in the UCS group. No stent-associated significant adverse events occurred in either the WCS or UCS groups. In the multivariate analysis, WCS placement and chemotherapy were identified as independent predictors of 16-week stent patency. WCS group showed comparable migration rate and significantly more durable long-term stent patency compared with UCS group for the palliation of GOO in patients with inoperable gastric cancer.

  2. Malignant inferior vena cava obstruction involving right atrium. Palliative treatment with self expandable metallic stent

    International Nuclear Information System (INIS)

    Shao Guoliang; Wang Jianhua; Zhou Kangrong; Yan Zhiping

    2001-01-01

    Objective: To investigate the safety and efficacy of placement of self-expandable metallic stent within right atrium and inferior vena cava (ICV) in patients with malignant ICV obstruction involving right atrium. Methods: There were 5 male patients with advanced hepatocellular carcinoma, aged from 42 to 65 years (mean 56.3 years). The malignancies invaded right atrium and ICV simultaneously, and caused obstruction of ICV. These patients presented symptoms and signs of obstruction of ICV such as hepatomegaly, ascites, edema of lower extremities. 'Z' type stainless steel stents (7.5-10.0 cm in length and 2.5 cm in diameter) were selected for these patients. Part (1.0-3.0 cm in length) of stent was placed in right atrium and the rest was in ICV. Results: All of stents were placed successfully and obstructed ICV reopened. The symptoms of obstruction of ICV relieved or disappeared. There were no recurrence of symptoms of obstruction of ICV and any cardiac complication related to placement of stents in follow-up period (67-188 days). Conclusion: Placement of self-expandable metallic stent within right atrium and ICV in treatment of patients with malignant ICV obstruction involving right atrium is one of the safe and effective methods

  3. Metal stents for malignant biliary obstruction

    NARCIS (Netherlands)

    Laméris, J. S.; Stoker, J.

    1994-01-01

    The main problem in the palliative treatment of malignant biliary obstruction is recurrent jaundice and cholangitis due to clogging of the endoprostheses. Large-bore metal stents, which can be placed using small-sized delivery systems, have been recognized as an important gain. Their use has

  4. Self-expandable metal stents for malignant gastric outlet obstruction: A pooled analysis of prospective literature.

    Science.gov (United States)

    van Halsema, Emo E; Rauws, Erik A J; Fockens, Paul; van Hooft, Jeanin E

    2015-11-21

    To provide an overview of the clinical outcomes of self-expandable metal stent (SEMS) placement for malignant gastric outlet obstruction (MGOO). A systematic literature search was performed in PubMed of the literature published between January 2009 and March 2015. Only prospective studies that reported on the clinical success of stent placement for MGOO were included. The primary endpoint was clinical success, defined according to the definition used in the original article. Data were pooled and analyzed using descriptive statistics. Subgroup analyses were performed for partially covered SEMSs (PCSEMSs) and uncovered SEMSs (UCSEMSs) using Fisher's exact test. A total of 19 studies, including 1281 patients, were included in the final analysis. Gastric (42%) and pancreatic (37%) cancer were the main causes of MGOO. UCSEMSs were used in 76% of patients and PCSEMSs in 24%. The overall pooled technical success rate was 97.3% and the clinical success rate was 85.7%. Stent dysfunction occurred in 19.6% of patients, mainly caused by re-obstruction (12.6%) and stent migration (4.3%), and was comparable between PCSEMSs and UCSEMSs (21.2% vs 19.1%, respectively, P = 0.412). Re-obstruction was more common with UCSEMSs (14.9% vs 5.1%, P < 0.001) and stent migration was more frequent after PCSEMS placement (10.9% vs 2.2%, P < 0.001). The overall perforation rate was 1.2%. Bleeding was reported in 4.1% of patients, including major bleeding in 0.8%. The median stent patency ranged from 68 to 307 d in five studies. The median overall survival ranged from 49 to 183 d in 13 studies. The clinical outcomes in this large population showed that enteral stent placement was feasible, effective and safe. Therefore, stent placement is a valid treatment option for the palliation of MGOO.

  5. Self-expandable metal stents for malignant gastric outlet obstruction: A pooled analysis of prospective literature

    Science.gov (United States)

    van Halsema, Emo E; Rauws, Erik AJ; Fockens, Paul; van Hooft, Jeanin E

    2015-01-01

    AIM: To provide an overview of the clinical outcomes of self-expandable metal stent (SEMS) placement for malignant gastric outlet obstruction (MGOO). METHODS: A systematic literature search was performed in PubMed of the literature published between January 2009 and March 2015. Only prospective studies that reported on the clinical success of stent placement for MGOO were included. The primary endpoint was clinical success, defined according to the definition used in the original article. Data were pooled and analyzed using descriptive statistics. Subgroup analyses were performed for partially covered SEMSs (PCSEMSs) and uncovered SEMSs (UCSEMSs) using Fisher’s exact test. RESULTS: A total of 19 studies, including 1281 patients, were included in the final analysis. Gastric (42%) and pancreatic (37%) cancer were the main causes of MGOO. UCSEMSs were used in 76% of patients and PCSEMSs in 24%. The overall pooled technical success rate was 97.3% and the clinical success rate was 85.7%. Stent dysfunction occurred in 19.6% of patients, mainly caused by re-obstruction (12.6%) and stent migration (4.3%), and was comparable between PCSEMSs and UCSEMSs (21.2% vs 19.1%, respectively, P = 0.412). Re-obstruction was more common with UCSEMSs (14.9% vs 5.1%, P < 0.001) and stent migration was more frequent after PCSEMS placement (10.9% vs 2.2%, P < 0.001). The overall perforation rate was 1.2%. Bleeding was reported in 4.1% of patients, including major bleeding in 0.8%. The median stent patency ranged from 68 to 307 d in five studies. The median overall survival ranged from 49 to 183 d in 13 studies. CONCLUSION: The clinical outcomes in this large population showed that enteral stent placement was feasible, effective and safe. Therefore, stent placement is a valid treatment option for the palliation of MGOO. PMID:26604654

  6. Self-expandable metal stents for malignant gastric outlet obstruction: A pooled analysis of prospective literature

    NARCIS (Netherlands)

    van Halsema, Emo E.; Rauws, Erik A. J.; Fockens, Paul; van Hooft, Jeanin E.

    2015-01-01

    To provide an overview of the clinical outcomes of self-expandable metal stent (SEMS) placement for malignant gastric outlet obstruction (MGOO). A systematic literature search was performed in PubMed of the literature published between January 2009 and March 2015. Only prospective studies that

  7. Wing-shaped plastic stents vs. self-expandable metal stents for palliative drainage of malignant distal biliary obstruction: a randomized multicenter study.

    Science.gov (United States)

    Schmidt, Arthur; Riecken, Bettina; Rische, Susanne; Klinger, Christoph; Jakobs, Ralf; Bechtler, Matthias; Kähler, Georg; Dormann, Arno; Caca, Karel

    2015-05-01

    Previous studies have shown superior patency rates for self-expandable metal stents (SEMS) compared with plastic stents in patients with malignant biliary obstruction. The aim of this study was to compare stent patency, patient survival, and complication rates between a newly designed, wing-shaped, plastic stent and SEMSs in patients with unresectable, malignant, distal, biliary obstruction. A randomized, multicenter trial was conducted at four tertiary care centers in Germany. A total of 37 patients underwent randomization between March 2010 and January 2013. Patients underwent endoscopic retrograde cholangiography with insertion of either a wing-shaped, plastic stent without lumen or an SEMS.  Stent failure occurred in 10/16 patients (62.5 %) in the winged-stent group vs. 4/18 patients (22.2 %) in the SEMS group (P = 0.034). The median time to stent failure was 51 days (range 2 - 92 days) for the winged stent and 80 days (range 28 - 266 days) for the SEMS (P = 0.002). Early stent failure (< 8 weeks after placement) occurred in 8 patients (50 %) vs. 2 patients (11.1 %), respectively (P = 0.022). After obtaining the results from this interim analysis, the study was discontinued because of safety concerns. The frequency of stent failure was significantly higher in the winged-stent group compared with the SEMS group. A high incidence of early stent failure within 8 weeks was observed in the winged-stent group. Thus, the winged, plastic stent without central lumen may not be appropriate for mid or long term drainage of malignant biliary obstruction. Study registration ClinicalTrials.gov (NCT01063634). © Georg Thieme Verlag KG Stuttgart · New York.

  8. Retrograde or antegrade double-pigtail stent placement for malignant ureteric obstruction?

    International Nuclear Information System (INIS)

    Uthappa, M.C.; Cowan, N.C.

    2005-01-01

    AIM: To determine the optimum approach for double-pigtail stent placement in malignant ureteric obstruction. PATIENTS AND METHODS: Retrograde stent placement was attempted in a consecutive series of patients presenting with malignant ureteric obstruction. If retrograde stent placement was unsuccessful, percutaneous nephrostomy was performed immediately followed by elective antegrade stent placement. Identical digital C-arm fluoroscopy for image-guidance and conditions for anaesthesia and analgesia were employed for both retrograde and antegrade procedures. Identical 8 Fr (20-26 cm) double-pigtail hydrophilic coated stents were used for each approach. RESULTS: Retrograde placement was attempted in 50 ureters in 30 patients {19 male, 11 female, average age 61.4 yr (range 29-90 yr)} over a 24-month period. The success rate for retrograde ureteric stent placement was 50% (n=25/50). Technical failures were due to failure to identify the ureteric orifice (n=22), failure to cross the stricture (n=1), failure to pass the stent (n=1) and failure to pass a 4 Fr catheter (n=1). Antegrade placement was attempted in 25 ureters with a success rate of 96% (n=24/25). Failure in the one case was due to inability to cross an upper third stricture secondary to pyeloureteritis cystica. CONCLUSION: It is suggested that retrograde route should be the initial approach if imaging shows no involvement of ureteric orifice (UO), when nephrostomy is technically very difficult or in cases of solitary kidney. The antegrade route is preferred if imaging shows tumour occlusion of the UO or if there is a tight stricture very close to the uretero-vesical junction (UVJ) making purchase within the ureter difficult for crossing the stricture

  9. Factors leading to tracheobronchial self-expandable metallic stent fracture.

    Science.gov (United States)

    Chung, Fu-Tsai; Lin, Shu-Min; Chen, Hao-Cheng; Chou, Chun-Liang; Yu, Chih-Teng; Liu, Chien-Ying; Wang, Chun-Hua; Lin, Horng-Chyuan; Huang, Chien-Da; Kuo, Han-Pin

    2008-11-01

    This retrospective study was to determine factors that contribute to self-expandable metallic stent fracture in patients with tracheobronchial disease. From 2001 to 2006, 139 patients (age, 62.1 +/- 15.4 years; range, 23-87 years) with benign (n = 62) and malignant (n = 77) tracheobronchial disease received 192 Ultraflex (Boston Scientific, Natick, Mass) self-expandable metallic stents (98 in patients with benign disease and 94 in patients with malignant disease). Seventeen fractured self-expandable metallic stents were found; the incidence was 12.2% (17/139 patients) among patients with tracheobronchial disease. Tortuous airway (odds ratio, 4.06; 95% confidence interval, 1.04-18.34; P = .04) independently predicted self-expandable metallic stent fracture. Most self-expandable metallic stent fractures (64.7%, 11/17) were detected 500 to 1000 days after self-expandable metallic stent implantation. Clinical presentations for patients with fractured self-expandable metallic stents included dyspnea exacerbation (70.6%, 12/17) and cough (23.5%, 4/17). Self-expandable metallic stent fracture is not uncommon in patients with tracheobronchial disease. Tortuous airway is an independent predictor for it. Although management of the fractured self-expandable metallic stent in our study was feasible and safe, self-expandable metallic stents should be restricted to a more select population.

  10. Interval biliary stent placement via percutaneous ultrasound guided cholecystostomy: another approach to palliative treatment in malignant biliary tract obstruction.

    Science.gov (United States)

    Harding, James; Mortimer, Alex; Kelly, Michael; Loveday, Eric

    2010-12-01

    Percutaneous cholecystostomy is a minimally invasive procedure for providing gallbladder decompression, often in critically ill patients. It can be used in malignant biliary obstruction following failed endoscopic retrograde cholangiopancreatography when the intrahepatic ducts are not dilated or when stent insertion is not possible via the bile ducts. In properly selected patients, percutaneous cholecystostomy in obstructive jaundice is a simple, safe, and rapid option for biliary decompression, thus avoiding the morbidity and mortality involved with percutaneous transhepatic biliary stenting. Subsequent use of a percutaneous cholecystostomy for definitive biliary stent placement is an attractive concept and leaves patients with no external drain. To the best of our knowledge, it has only been described on three previous occasions in the published literature, on each occasion forced by surgical or technical considerations. Traditionally, anatomic/technical considerations and the risk of bile leak have precluded such an approach, but improvements in catheter design and manufacture may now make it more feasible. We report a case of successful interval metal stent placement via percutaneous cholecystostomy which was preplanned and achieved excellent palliation for the patient. The pros and cons of the procedure and approach are discussed.

  11. Interval Biliary Stent Placement Via Percutaneous Ultrasound Guided Cholecystostomy: Another Approach to Palliative Treatment in Malignant Biliary Tract Obstruction

    International Nuclear Information System (INIS)

    Harding, James; Mortimer, Alex; Kelly, Michael; Loveday, Eric

    2010-01-01

    Percutaneous cholecystostomy is a minimally invasive procedure for providing gallbladder decompression, often in critically ill patients. It can be used in malignant biliary obstruction following failed endoscopic retrograde cholangiopancreatography when the intrahepatic ducts are not dilated or when stent insertion is not possible via the bile ducts. In properly selected patients, percutaneous cholecystostomy in obstructive jaundice is a simple, safe, and rapid option for biliary decompression, thus avoiding the morbidity and mortality involved with percutaneous transhepatic biliary stenting. Subsequent use of a percutaneous cholecystostomy for definitive biliary stent placement is an attractive concept and leaves patients with no external drain. To the best of our knowledge, it has only been described on three previous occasions in the published literature, on each occasion forced by surgical or technical considerations. Traditionally, anatomic/technical considerations and the risk of bile leak have precluded such an approach, but improvements in catheter design and manufacture may now make it more feasible. We report a case of successful interval metal stent placement via percutaneous cholecystostomy which was preplanned and achieved excellent palliation for the patient. The pros and cons of the procedure and approach are discussed.

  12. Ultraflex precision colonic stent placement as a bridge to surgery in patients with malignant colon obstruction

    DEFF Research Database (Denmark)

    Fregonese, D.; Naspetti, R.; Ferrer, S.

    2008-01-01

    Background: Emergency surgery for malignant colon obstruction entails relatively high morbidity and mortality rates and typically necessitates a 2-step resection. These problems might be potentially mitigated by placement of a self-expanding metal stent (SEMS) as a bridge to surgery. A nitinol...... colorectal SEMS may offer several advantages, but available evidence on the utility of this SEMS type remains highly limited. Objective: Our purpose was to evaluate the effectiveness and safety as a bridge to surgery of a nitinol SEMS designed for colorectal use. Design: Prospective and retrospective...... success in alleviating colonic obstructive symptoms, and bridging to elective surgery. Results: Technical success was achieved in 97% of patients with a 95% CI of 85% to 100% and clinical success in 81% (95% CI, 64%-92%). Elective surgery was performed in 94% (95% CI, 81%-99%) of patients at a median...

  13. Tracheal stent placement for the emergency management of tracheal collapse in dogs.

    Science.gov (United States)

    Beal, Matthew W

    2013-08-01

    Dogs with tracheal collapse may present with life-threatening upper airway obstruction. In most instances, a conservative approach to treatment including oxygen support coupled with sedation and cooling measures will relieve respiratory effort and thus relieve airway obstruction. Dogs that fail this conservative approach require endotracheal intubation to ensure a patent airway. This population of patients would benefit from a more definitive, yet palliative treatment option to acutely relieve upper airway obstruction. Placement of a self-expanding metallic stent that spans the affected portion of the trachea will acutely provide the patient with a sustained patent airway and optimize the likelihood of a positive outcome. © 2013 Elsevier Inc. All rights reserved.

  14. Polydioxanone biodegradable stent placement in a canine urethral model: analysis of inflammatory reaction and biodegradation.

    Science.gov (United States)

    Park, Jung-Hoon; Song, Ho-Young; Shin, Ji Hoon; Kim, Jin Hyoung; Jun, Eun Jung; Cho, Young Chul; Kim, Soo Hwan; Park, Jihong

    2014-08-01

    To investigate the inflammatory reaction and perform quantitative analysis of biodegradation after placement of a polydioxanone (PDO) biodegradable stent in a canine urethral model. PDO biodegradable stents were placed in the proximal and distal urethra of nine male mongrel dogs. The dogs were euthanized 4 weeks (group A; n = 3), 8 weeks (group B; n = 3), or 12 weeks (group C; n = 3) after stent placement. The luminal diameter of the stent-implanted urethra was assessed by follow-up retrograde urethrography, and histologic findings were obtained after the dogs were killed. Stents were removed after euthanasia, and their surface morphology and molecular weight were evaluated. Hematologic examination was performed to evaluate inflammatory reaction. Stent placement was technically successful in all dogs. The average luminal diameter gradually decreased. The average number of epithelial layers (2.93 vs 4.42; P stents were completely decomposed. An experimental study in a canine urethral model has demonstrated acceptable inflammatory reaction with gradually increasing granulation tissue but no luminal obstruction within 12 weeks. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  15. Palliation of Malignant Upper Gastrointestinal Obstruction with Self-Expandable Metal Stent

    International Nuclear Information System (INIS)

    Morikawa, Soichiro; Suzuki, Azumi; Nakase, Kojiro; Yasuda, Kenjiro

    2012-01-01

    To assess the technical success, ability to eat, complications and clinical outcomes of patients with self-expandable metal stent (SEMS) placed for malignant upper gastrointestinal (GI) obstruction. Data was collected retrospectively on patients who underwent SEMS placement for palliation of malignant upper GI obstruction by reviewing hospital charts from June 1998 to May 2011. Main outcome measurements were technical success, gastric outlet obstruction scoring system (GOOSS) score before and after treatment, complications, and survival. A total of 82 patients underwent SEMS placement with malignant upper GI obstruction. The initial SEMS placement was successful in 77 patients (93.9%). The mean GOOSS score was 0.56 before stenting and 1.92 (p < 0.001) after treatment. Complications arose in 12 patients (14.6%): stent migration in 1 patient (1.2%), perforation in 1 (1.2%), and obstruction of stent due to tumor ingrowth in 10 (12.2%). The median survival time after stenting was 52 days (6-445). SEMS placement is an effective and safe treatment for palliation of malignant upper GI obstruction. It provides lasting relief in dysphagia and improves the QOL of patients.

  16. Palliation of Malignant Upper Gastrointestinal Obstruction with Self-Expandable Metal Stent

    Energy Technology Data Exchange (ETDEWEB)

    Morikawa, Soichiro; Suzuki, Azumi; Nakase, Kojiro; Yasuda, Kenjiro [Kyoto Second Red Cross Hospital, Kyoto (Japan)

    2012-02-15

    To assess the technical success, ability to eat, complications and clinical outcomes of patients with self-expandable metal stent (SEMS) placed for malignant upper gastrointestinal (GI) obstruction. Data was collected retrospectively on patients who underwent SEMS placement for palliation of malignant upper GI obstruction by reviewing hospital charts from June 1998 to May 2011. Main outcome measurements were technical success, gastric outlet obstruction scoring system (GOOSS) score before and after treatment, complications, and survival. A total of 82 patients underwent SEMS placement with malignant upper GI obstruction. The initial SEMS placement was successful in 77 patients (93.9%). The mean GOOSS score was 0.56 before stenting and 1.92 (p < 0.001) after treatment. Complications arose in 12 patients (14.6%): stent migration in 1 patient (1.2%), perforation in 1 (1.2%), and obstruction of stent due to tumor ingrowth in 10 (12.2%). The median survival time after stenting was 52 days (6-445). SEMS placement is an effective and safe treatment for palliation of malignant upper GI obstruction. It provides lasting relief in dysphagia and improves the QOL of patients.

  17. Individualization of metal stents for management of gastric outlet obstruction caused by distal stomach cancer: a prospective study.

    Science.gov (United States)

    Shi, Ding; Bao, Yin-Su; Liu, Yong-Pan

    2013-08-01

    The use of various kinds of metal stents has emerged as an effective palliative treatment for malignant gastric outlet obstruction (GOO). However, most of these metal stents were designed for use in the esophagus or intestine and have a high incidence of stent obstruction and stent migration when used elsewhere. To evaluate the efficacy and safety of individualized stents (designed according to the shape and size of the GOO) in order to determine whether such stents could reduce the incidence of stent obstruction and migration. Multicenter, prospective, clinical trial. Two tertiary-care referral centers. Thirty-seven patients who presented with symptomatic unresectable malignant GOO caused by distal gastric cancer between April 2005 and June 2009. Placement of the individualized metal stents. The primary endpoint was to optimize stent resolution of proximal obstruction as determined by a GOO scoring system. Secondary endpoints were success rates, survival rates, and adverse events. Technical and clinical success was achieved in 97.3% and 94.4% of patients, respectively. The rate of resolution of proximal obstruction by a proximal stent was 97.3%. There were no procedure-related perforations or deaths. No stent migration or obstruction by tumor growth were found. The mean survival time was 232 days (range 28-387 days). A single-arm study in tertiary-care centers. Placement of individualized stents is a safe and effective modality for the palliation of malignant GOO caused by distal stomach cancer and can help reduce tumor ingrowth and stent migration. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  18. Metallic Stent Expansion Rate at Day One Predicts Stent Patency in Patients with Gastric Outlet Obstruction.

    Science.gov (United States)

    Ye, Bing-Wei; Chou, Chung-Kai; Hsieh, Yun-Cheng; Li, Chung-Pin; Chao, Yee; Hou, Ming-Chih; Lin, Han-Chieh; Lee, Kuei-Chuan

    2017-05-01

    Self-expandable metallic stent insertion has been a mainstream treatment for relieving the obstructive symptoms of malignant gastric outlet obstruction (MGOO), a late-stage complication of gastrointestinal malignancies. This study aims to investigate the predictive value of stent expansion rates in clinical outcomes in patients with MGOO. Eighty-seven patients with inoperable MGOO receiving metallic stents were reviewed retrospectively from April 2010 to December 2014. Clinical outcomes, predictors of stent patency, and survival were analyzed. The technical and clinical success rates were 100 and 94.3%, respectively. The median stent patency time was 114 days (range 13-570 days). The median survival time was 133 days (range 13-1145 days). Stent dysfunctions occurred in 28 patients (32.2%), with restenosis accounting for the majority (82%). The stent expansion rate ≥75% at Day 1 predicted the stent patency [hazard ratio (HR) 0.12, P = 0.04]. However, it did not correlate with survival. Non-gastric cancer origins (HR 2.41, P = 0.002) and peritoneal carcinomatosis (HR 2.54, P = 0.001) correlated with poor survival. However, post-stent chemotherapy (HR 0.55, P = 0.03) was related to better outcome. The comparison of clinical outcomes of first and second stent insertions showed no significant difference in the stent expansion rate either at Day 0 and Day 1 (P = 0.97 and P = 0.57). Self-expandable metallic stent insertion is a safe and effective treatment for relieving the obstructive symptoms. The stent expansion rate ≥75% at Day 1 is a novel stent-related predictor of stent patency.

  19. Expandable metallic stents in the palliative treatment of malignant tracheobronchial stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong Woong; Jung, Gyoo Sik; Kim, Seong Min; Lee, Seung Ryong; Kim, Hyun Sook; Huh, Jin Do; Joh, Young Duk [Kosin Medical College, Pusan (Korea, Republic of)

    1998-05-01

    The purpose of this study is to report the outcome of using expandable metallic stent in the management of malignant tracheobronchial stenosis with dyspnea. Under fluoroscopic and bronchoscopic guidance, seven patients with malignant airway stenosis were treated with ten expandable metallic stents. The cause of stenosis was metastasis from esophageal cancer in five patients, recurrent adenoid cystic carcinoma of the trachea in one, and primary lung cancer in one. The major sites of obstruction were the trachea in four patients, the left main bronchus in one, the trachea and left main bronchus in one, and the trachea and both bronchi in one. Chest radiography (n=7), bronchoscopy (n=5), pulmonary function test (PFT)(n=3), and spirometry(n=1) were performed before and after stent placement. In all seven patients, the stent was successfully placed at the lesion sites and dyspnea began to improve immediately. After the procedure, chest radiography and bronchoscopy showed an increase in airway diameter. After the procedure, chest radiography and bronchoscopy showed an increase in airway diameter. After stent placement, forced vital capacity (FVC) and forced expiratory volume in one second (FEV1) improved 53% and 56%, respectively. Peak flow velocity also changed from 46 L/min to 200 L/min. During median follow-up of 67 (41-1565) days, one stent migration occurred. In one patient, proximal tumor overgrowth occurred, and in one, tumor ingrowth was treated with balloon dilatation. For in the palliative treatment of malignant tracheobronchial stenosis with dyspnea, placement of expandable metal stents is safe and effective. (author). 21 refs., 1 tabs., 3 figs.

  20. Expandable metallic stents in the palliative treatment of malignant tracheobronchial stenosis

    International Nuclear Information System (INIS)

    Park, Jong Woong; Jung, Gyoo Sik; Kim, Seong Min; Lee, Seung Ryong; Kim, Hyun Sook; Huh, Jin Do; Joh, Young Duk

    1998-01-01

    The purpose of this study is to report the outcome of using expandable metallic stent in the management of malignant tracheobronchial stenosis with dyspnea. Under fluoroscopic and bronchoscopic guidance, seven patients with malignant airway stenosis were treated with ten expandable metallic stents. The cause of stenosis was metastasis from esophageal cancer in five patients, recurrent adenoid cystic carcinoma of the trachea in one, and primary lung cancer in one. The major sites of obstruction were the trachea in four patients, the left main bronchus in one, the trachea and left main bronchus in one, and the trachea and both bronchi in one. Chest radiography (n=7), bronchoscopy (n=5), pulmonary function test (PFT)(n=3), and spirometry(n=1) were performed before and after stent placement. In all seven patients, the stent was successfully placed at the lesion sites and dyspnea began to improve immediately. After the procedure, chest radiography and bronchoscopy showed an increase in airway diameter. After the procedure, chest radiography and bronchoscopy showed an increase in airway diameter. After stent placement, forced vital capacity (FVC) and forced expiratory volume in one second (FEV1) improved 53% and 56%, respectively. Peak flow velocity also changed from 46 L/min to 200 L/min. During median follow-up of 67 (41-1565) days, one stent migration occurred. In one patient, proximal tumor overgrowth occurred, and in one, tumor ingrowth was treated with balloon dilatation. For in the palliative treatment of malignant tracheobronchial stenosis with dyspnea, placement of expandable metal stents is safe and effective. (author). 21 refs., 1 tabs., 3 figs

  1. Interventional Management of Delayed and Massive Hemobilia due to Arterial Erosion by Metallic Biliary Stent

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Hee Seok [Dept. of Radiology, Gyeongsang National University Hospital, Jinju (Korea, Republic of); Shin, Tae Beom [Dept. of Diagnostic Radiology, Kimhae Jung Ang Hospital, Kimhae (Korea, Republic of); Hwang, Jae Cheol [Dept. of Radiology, Ulsan Hospital, Ulsan (Korea, Republic of); Bae, Jae Ik [Dept. of Radiology, Ajou University Hospital, Suwon (Korea, Republic of); Kim, Chang Won [Dept. of Radiology, Busan National University Hospital, Busan (Korea, Republic of)

    2012-01-15

    To evaluate the effectiveness of interventional management for delayed and massive hemobilia secondary to arterial erosion self expandable metallic stent (SES) in with biliary duct malignancy. Over 8-year period, eight patients who suffered from delayed massive hemobilia after SES placement for malignant biliary obstruction as palliative procedure, were included. The mean period between SES placement and presence of massive gastrointestinal hemorrhage was 66.5 days (15-152 days), pancreatic cancer (n = 2), Klatskin tumor (n = 2), common bile duct cancer (n = 2), intrahepatic cholangiocarcinoma (n = 1), and gastric cancer with ductal invasion (n = 1). Angiographic findings were pseudoaneurysm (n = 6), contrast extravasation (n = 1) and arterial spasm at segment (n = 1). Six patients underwent embolization of injured vessels using microcoils and N-butyl cyanoacrylate. Two patients underwent stent graft placement at right hepatic artery to prevent ischemic hepatic damage because of the presence of portal vein occlusion. Massive hemobilia was successfully controlled by the embolization of arteries (n = 6) and stent graft placement (n = 2) without related complications. The delayed massive hemobilia to arterial erosion metallic biliary stent is rare this complication be successfully treated by interventional management.

  2. Comparison of a New Polytetrafluoroethylene-Covered Metallic Stent to a Noncovered Stent in Canine Ureters

    International Nuclear Information System (INIS)

    Chung, Hwan-Hoon; Lee, Seung Hwa; Cho, Sung Bum; Park, Hong Suk; Kim, Young Sik; Kang, Byung Chul; Frisoli, Joan K.; Razavi, Mahmood K.

    2008-01-01

    The aim of this study was to determine the feasibility of using a newly designed polytetrafluoroethylene (PTFE)-covered metallic stent in the ureter by comparing its effectiveness with that of the noncovered stent in a canine model. We placed 14 stents in the ureters of seven mongrel dogs that weighed 30-40 kg each. The covered and noncovered stents were deployed in the right and left ureters, respectively, of six dogs. In the seventh dog, a covered stent and a double-J catheter were inserted in the right ureter, and a covered stent only was inserted in the left ureter. The first six dogs were sacrificed at 5, 10, and 15 weeks after deployment of the stents (two for each follow-up period), and the seventh dog was sacrificed at 30 weeks. There was no migration or poor expansion of any of the stents observed on plain radiography. On intravenous pyelogram and retrograde pyelogram, all of the covered stents at each follow-up period had patent lumens at the stented segments without hydronephrosis, and the passage of contrast material through it was well preserved. The noncovered stents in the dogs sacrificed at 5 and 10 weeks and one of the two dogs sacrificed at 15 weeks showed near-complete occlusion of the stent lumen due to ingrowth of the soft tissue, and severe hydronephrosis was also noted. The noncovered stent in the other dog sacrificed at 15 weeks showed the passage of contrast material without hydronephrosis, but the lumen of the stent was still nearly occluded by the soft tissue. There was no evidence of hydronephrosis or passage disturbance of the contrast material in both ureters of the dog sacrificed at 30 weeks. We conclude that the newly designed PTFE-covered stent effectively prevented the luminal occlusion caused by urothelial hyperplasia compared to the near-total occlusion of the noncovered stents, and no migration of the covered stents was noted

  3. Osteonecrosis of Femoral Head Occurred after Stent Placement of Femoral Artery

    Directory of Open Access Journals (Sweden)

    Akiyoshi Shimatani

    2014-01-01

    Full Text Available We present a case of osteonecrosis of femoral head (ONFH that occurred after stent angiography of femoral artery for the treatment of arteriosclerosis obliterans (ASO of left inferior limb in a 76-year-old woman. No case of late collapse of femoral head as a complication of endovascular procedure such as stent placement has been previously documented. We considered that ONFH occurred after detaining stent at a junction of left deep femoral artery for the treatment of the ischemia of left lateral and medial femoral circumflex artery.

  4. Metallic Ureteric Stents in Malignant Ureteric Obstruction: a Systematic Review.

    Science.gov (United States)

    Khoo, C C K; Abboudi, H; Cartwright, R; El-Husseiny, T; Dasgupta, R

    2018-02-02

    The effectiveness of metallic stents in the management of malignant ureteric obstruction (MUO) is unclear. This systematic review evaluates the use of four commercially available metallic stents (Resonance, Memokath 051, Uventa and Allium URS). Twenty-one studies met eligibility criteria. Overall success rates ranged from 88% for the Allium stent to 65% for Memokath 051. Resonance demonstrated the lowest migration rate (1%). Uventa had the lowest obstruction rate (6%). Metallic ureteric stents offer a viable alternative in the management of MUO. Further high quality studies are required to assess cost effectiveness and refine specific indications based on aetiology and level of the ureteric obstruction. Copyright © 2018. Published by Elsevier Inc.

  5. Long-term Results of Endovascular Stent Graft Placement of Ureteroarterial Fistula

    International Nuclear Information System (INIS)

    Okada, Takuya; Yamaguchi, Masato; Muradi, Akhmadu; Nomura, Yoshikatsu; Uotani, Kensuke; Idoguchi, Koji; Miyamoto, Naokazu; Kawasaki, Ryota; Taniguchi, Takanori; Okita, Yutaka; Sugimoto, Koji

    2013-01-01

    PurposeTo evaluate the safety, efficacy, and long-term results of endovascular stent graft placement for ureteroarterial fistula (UAF).MethodsWe retrospectively analyzed stent graft placement for UAF performed at our institution from 2004 to 2012. Fistula location was assessed by contrast-enhanced computed tomography (CT) and angiography, and freedom from hematuria recurrence and mortality rates were estimated.ResultsStent graft placement for 11 UAFs was performed (4 men, mean age 72.8 ± 11.6 years). Some risk factors were present, including long-term ureteral stenting in 10 (91 %), pelvic surgery in 8 (73 %), and pelvic radiation in 5 (45 %). Contrast-enhanced CT and/or angiography revealed fistula or encasement of the artery in 6 cases (55 %). In the remaining 5 (45 %), angiography revealed no abnormality, and the suspected fistula site was at the crossing area between urinary tract and artery. All procedures were successful. However, one patient died of urosepsis 37 days after the procedure. At a mean follow-up of 548 (range 35–1,386) days, 4 patients (36 %) had recurrent hematuria, and two of them underwent additional treatment with secondary stent graft placement and surgical reconstruction. The hematuria recurrence-free rates at 1 and 2 years were 76.2 and 40.6 %, respectively. The freedom from UAF-related and overall mortality rates at 2 years were 85.7 and 54.9 %, respectively.ConclusionEndovascular stent graft placement for UAF is a safe and effective method to manage acute events. However, the hematuria recurrence rate remains high. A further study of long-term results in larger number of patients is necessary

  6. Self-expandable metalic endotracheal stent

    International Nuclear Information System (INIS)

    Do, Young Soo; Cho, Dae Soon; Cho, Kyung Ja; Lee, Young Soo; Lee, Mi Jae

    1993-01-01

    Six bare stents and six covered stents were inserted in the trachea of 12 dogs under general anesthesia. After 1-10 weeks of observation, the dogs were killed, and the trachea and lung were examined grossly and histologically. Pneumonia and stent migration were observed more frequently at covered stent group. Inflammatory change of the trachea was more severe at covered stent group. In conclusion, we believe that it is inadequate to insert silicone covered stent in the tracheobronchial tree. (Author)

  7. Stent malapposition, as a potential mechanism of very late stent thrombosis after bare-metal stent implantation: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Higuma, Takumi, E-mail: higuma@cc.hirosaki-u.ac.jp; Abe, Naoki; Hanada, Kenji; Yokoyama, Hiroaki; Tomita, Hirofumi; Okumura, Ken

    2014-04-15

    A 90-year-old man was admitted to our hospital with acute ST-segment elevation myocardial infarction. He had a history of post-infarction angina pectoris 79 months ago and had a bare-metal stent (BMS) implanted in the proximal left anterior descending artery at our hospital. Emergent coronary angiography demonstrated thrombotic occlusion in the previously stented segment. After catheter thrombectomy, antegrade flow was restored, but 90% stenosis with haziness persisted in the proximal and distal portions of the previously stented segment. Intravascular ultrasound imaging showed interstrut cavities or stent malapposition at the proximal and distal sites of stented segment. In close proximity to the sites, residual thrombi were also observed. Optical coherence tomography (OCT) demonstrated neither lipid-laden neointimal tissue nor rupture but clearly demonstrated residual thrombus adjacent to the malapposed region in addition to the stent malapposition. PCI with balloon was successfully performed and stent apposition was confirmed by OCT. Stent malapposition is an unusual mechanism of very late stent thrombosis after BMS implantation. OCT can clearly reveal the etiology of stent thrombosis.

  8. Radiologic Placement of Uncovered Stents for the Treatment of Malignant Colonic Obstruction Proximal to the Descending Colon

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jehong; Kwon, Se Hwan, E-mail: Kwon98@khu.ac.kr [Kyung Hee University, Department of Radiology, College of Medicine (Korea, Republic of); Lee, Chang-Kyun [Kyung Hee University, Department of Internal Medicine, College of Medicine (Korea, Republic of); Park, Sun Jin [Kyung Hee University, Department of Surgery, College of Medicine (Korea, Republic of); Oh, Ji Young [Kyung Hee University Hospital at Gangdong, Department of Radiology (Korea, Republic of); Oh, Joo Hyeong [Kyung Hee University, Department of Radiology, College of Medicine (Korea, Republic of)

    2017-01-15

    PurposeTo evaluate the safety, feasibility, and patency rates of radiologic placement of uncovered stents for the treatment of malignant colonic obstruction proximal to the descending colon.Materials and MethodsThis was a retrospective, single-center study. From May 2003 to March 2015, 53 image-guided placements of uncovered stents (44 initial placements, 9 secondary placements) were attempted in 44 patients (male:female = 23:21; mean age, 71.8 years). The technical and clinical success, complication rates, and patency rates of the stents were also evaluated. Technical success was defined as the successful deployment of the stent under fluoroscopic guidance alone and clinical success was defined as the relief of obstructive symptoms or signs within 48 h of stent deployment.ResultsIn total, 12 (27.3 %) patients underwent preoperative decompression, while 32 (72.7 %) underwent decompression with palliative intent. The technical success rate was 93.2 % (41/44) for initial placement and 88.9 % (8/9) for secondary placement. Secondary stent placement in the palliative group was required in nine patients after successful initial stent placement due to stent obstruction from tumor ingrowth (n = 7) and stent migration (n = 2). The symptoms of obstruction were relieved in all successful cases (100 %). In the palliative group, the patency rates were 94.4 % at 1 month, 84.0 % at 3 months, 64.8 % at 6 months, and 48.6 % at 12 months.ConclusionsThe radiologic placement of uncovered stents for the treatment of malignant obstruction proximal to the descending colon is feasible and safe, and provides acceptable clinical results.

  9. A novel endobronchial approach to massive hemoptysis complicating silicone Y-stent placement for tracheobronchomalacia

    Science.gov (United States)

    Ryu, Changwan; Boffa, Daniel; Bramley, Kyle; Pisani, Margaret; Puchalski, Jonathan

    2018-01-01

    Abstract Rationale: Airway stabilization for severe, symptomatic tracheobronchomalacia (TBM) may be accomplished by silicone Y-stent placement. Common complications of the Y-stent include mucus plugging and granulation tissue formation. Patient concerns: We describe a rare case of massive hemoptysis originating from a silicone Y-stent placed for TBM. Diagnoses: An emergent bronchoscopy showed an actively bleeding, pulsatile vessel at the distal end of the left bronchial limb of the Y-stent. It was felt that the bleeding was caused by, or at least impacted by, the distal left bronchial limb of the Y-stent eroding into the airway wall. Interventions: We hypothesized that placement of oxidized regenerated cellulose (ORC) would provide initial hemostasis, and the subsequent placement of a biocompatible surgical sealant would lead to definitive resolution. Outcomes: ORC provided sufficient hemostasis and the subsequent synthetic polymer reinforced the tissue for complete cessation of the bleed. Lessons: The combined use of ORC and a biocompatible surgical sealant provided long-term management for life-threatening hemoptysis, and potentially morbid procedures such as embolization or surgery were avoided by advanced endobronchial therapy. PMID:29465600

  10. Biodegradable Metals for Cardiovascular Stent Application: Interests and New Opportunities

    Directory of Open Access Journals (Sweden)

    Maryam Moravej

    2011-06-01

    Full Text Available During the last decade, biodegradable metallic stents have been developed and investigated as alternatives for the currently-used permanent cardiovascular stents. Degradable metallic materials could potentially replace corrosion-resistant metals currently used for stent application as it has been shown that the role of stenting is temporary and limited to a period of 6–12 months after implantation during which arterial remodeling and healing occur. Although corrosion is generally considered as a failure in metallurgy, the corrodibility of certain metals can be an advantage for their application as degradable implants. The candidate materials for such application should have mechanical properties ideally close to those of 316L stainless steel which is the gold standard material for stent application in order to provide mechanical support to diseased arteries. Non-toxicity of the metal itself and its degradation products is another requirement as the material is absorbed by blood and cells. Based on the mentioned requirements, iron-based and magnesium-based alloys have been the investigated candidates for biodegradable stents. This article reviews the recent developments in the design and evaluation of metallic materials for biodegradable stents. It also introduces the new metallurgical processes which could be applied for the production of metallic biodegradable stents and their effect on the properties of the produced metals.

  11. [Hemolytic anemia secondary to the placement of a portosystemic stented shunt].

    Science.gov (United States)

    Carrillo-Esper, Raúl; Carrillo-Cortes, Ulises; Carrillo-Córdova, Jorge Raúl; Carrillo-Córdova, Luis Daniel; Carrillo-Córdova, Carlos Alberto; Carrillo-Córdova, Dulce María

    2013-01-01

    portal hypertension and variceal hemorrhage are common complications of hepatic cirrhosis, both associated with a high morbimortality. Portal system decompression by the placement of a transjugular intrahepatic portosystemic stented shunt, can reduce portal venus pressure and is effective controling complications of portal hypertension, like variceal hemorrhage and ascitis. The aim of this document is to describe a case of hemolytic anemia secondary to the placement of a transjugular intrahepatic portosystemic stented shunt. patient with portal hypertension secondary to liver cirrosis was given a transjugular intrahepatic portosystemic stented shunt for recurrent variceal hemorrhage. After the procedure, hemoglobin decreased 2 g/dL, associated with reticulocitosis, hipohaptoglobinemia, elevated lactic dehydrogenase and indirect hyperbilirrubinemia with negative Coombs test. The peripheral blood smear showed abnormal erythrocytes, with the prevalence of schistocytes. The final diagnosis was hemolytic anemia secondary to transjugular intrahepatic portosystemic stented shunt. the hemolytic anemia secondary to Transjugular Intrahepatic Portosystemic Stented Shunt is a rare complication. Usually, it has a benign prognosis, and it is self-limited once the stent is endothelialized.

  12. Palliation of Postoperative Gastrointestinal Anastomotic Malignant Strictures with Flexible Covered Metallic Stents: Preliminary Results

    International Nuclear Information System (INIS)

    Lee, Jeong-Min; Han, Young Min; Lee, Sang Yong; Kim, Chong Soo; Yang, Doo Hyun; Lee, Seung Ok

    2001-01-01

    Purpose: To evaluate the efficacy of the placement of covered metallic stents for palliation of gastrointestinal anastomotic strictures secondary to recurrent gastric cancer.Methods: Under fluoroscopic guidance, placement of one or two self-expandable covered metallic stents was attempted perorally in 11 patents (aged 48-76 years) with anastomotic stenoses due to recurrent gastric malignancies. The strictures involved both the afferent and efferent loops in three patients. All patients had poor peroral food intake with severe nausea and vomiting after ingestion. The technical and clinical success was evaluated.Results: Placement of the covered stent was technically successful in 13 of 15 (87%) attempts in ten patients. After the procedure, 9 of 11 (82%) patients overall were able to ingest at least a liquid diet and had markedly decreased incidence of vomiting. During the follow-up of 2-31 weeks (mean 8.5 weeks) there were no major complications.Conclusion: These preliminary results suggest that flexible, covered stents may provide effective palliation of malignant anastomotic stricture secondary to recurrent gastric cancer

  13. Combined Arterial Infusion and Stent Implantation Compared with Metal Stent Alone in Treatment of Malignant Gastroduodenal Obstruction

    International Nuclear Information System (INIS)

    Wang Zhongmin; Chen Kemin; Gong Ju; Zheng Yunfeng; Wang Tianxiang

    2009-01-01

    Many patients with malignant gastroduodenal obstruction have an unresectable primary lesion and distant metastases, which may prompt palliative management to allow the patient to eat and to improve the quality of life. Intraluminal metallic stent implantation (MSI) under fluoroscopic guidance has been reported to be an effective option for symptomatic relief in these patients, with a good safety record. An alternative, dual interventional therapy (DIT), has been used during the last decade, in which prosthesis insertion is followed by intra-arterial chemotherapy via the tumor-feeding arteries. The aim of this study was to compare success rates, complication rates, and survival time between MSI and DIT in patients who presented with gastroduodenal obstruction from advanced upper gastrointestinal tract cancer. All consecutive patients with malignant gastroduodenal obstruction seen at our center between October 2002 and August 2007 were retrospectively studied. Patients were treated palliatively by either MSI or DIT by the patient's or the next of kin's decision. Outcomes included technical and clinical success, complication rates, and survival. Of the 164 patients with malignant gastric and duodenal outlet obstructions, 80 (49%) underwent stent insertion as the primary therapy, while the remaining 84 (51%) received DIT. Clinical characteristics were similar between the two groups. In the MSI cohort initial stent implantation was successful in 73 patients (91%), two stents were used in 5 patients, and delayed additional stent insertion for stent obstruction related to tumor overgrowth was required in 3 patients during follow-up. In the DIT cohort the technical success rate was 94%, 3 patients required two stents, and stent obstruction occurred in 2 patients after initial stent placement. Early postprocedural clinical success, indicated by average dysphagia score, improved significantly in both groups: MSI group, from 4.56 to 1.51 (P < 0.01); and DIT group, from 4

  14. Use of a colonoscope for distal duodenal stent placement in patients with malignant obstruction

    NARCIS (Netherlands)

    S.M. Jeurnink (Suzanne); A. Repici (Alessandro); C. Luigiano (Carmelo); N. Pagano (Nico); E.J. Kuipers (Ernst); P.D. Siersema (Peter)

    2009-01-01

    textabstractBackground: Stent placement in the distal duodenum or proximal jejunum with a therapeutic gastroscope can be difficult, because of the reach of the endoscope, loop formation in the stomach, and flexibility of the gastroscope. The use of a colonoscope may overcome these problems.

  15. A comparison of the temporary placement of 3 different self-expanding stents for the treatment of refractory benign esophageal strictures: a prospective multicentre study

    Directory of Open Access Journals (Sweden)

    Canena Jorge Manuel

    2012-06-01

    Full Text Available Abstract Background Refractory benign esophageal strictures (RBESs have been treated with the temporary placement of different self-expanding stents with conflicting results. We compared the clinical effectiveness of 3 types of stents: self-expanding plastic stents (SEPSs, biodegradable stents, and fully covered self-expanding metal stents (FCSEMSs, for the treatment of RBES. Methods This study prospectively evaluated 3 groups of 30 consecutive patients with RBESs who underwent temporary placement of either SEPSs (12 weeks, n = 10, biodegradable stents (n = 10 or FCSEMSs (12 weeks, n = 10. Data were collected to analyze the technical success and clinical outcome of the stents as evaluated by recurrent dysphagia, complications and reinterventions. Results Stent implantation was technically successful in all patients. Migration occurred in 11 patients: 6 (60% in the SEPS group, 2 (20% in the biodegradable group and 3 (30% in the FCSEMS group (P = 0.16. A total of 8/30 patients (26.6% were dysphagia-free after the end of follow-up: 1 (10% in the SEPS group, 3 (30% in the biodegradable group and 4 (40% in the FCSEMS group (P = 0.27. More reinterventions were required in the SEPS group (n = 24 than in the biodegradable group (n = 13 or the FCSEMS group (n = 13 (P = 0.24. Multivariate analysis showed that stricture length was significantly associated with higher recurrence rates after temporary stent placement (HR = 1.37; 95% CI = 1.08-1.75; P = 0.011. Conclusions Temporary placement of a biodegradable stent or of a FCSEMS in patients with RBES may lead to long-term relief of dysphagia in 30 and 40% of patients, respectively. The use of SEPSs seems least preferable, as they are associated with frequent stent migration, more reinterventions and few cases of long-term improvement. Additionally, longer strictures were associated with a higher risk of recurrence.

  16. [Findings from Total Colonoscopy in Obstructive Colorectal Cancer Patients Who Underwent Stent Placement as a Bridge to Surgery(BTS)].

    Science.gov (United States)

    Maruo, Hirotoshi; Tsuyuki, Hajime; Kojima, Tadahiro; Koreyasu, Ryohei; Nakamura, Koichi; Higashi, Yukihiro; Shoji, Tsuyoshi; Yamazaki, Masanori; Nishiyama, Raisuke; Ito, Tatsuhiro; Koike, Kota; Ikeda, Takashi; Takayanagi, Yasuhiro; Kubota, Hiroyuki

    2017-11-01

    We clinically investigated 34 patients with obstructive colorectal cancer who underwent placement of a colonic stent as a bridge to surgery(BTS), focusing on endoscopic findings after stent placement.Twenty -nine patients(85.3%)underwent colonoscopy after stent placement, and the entire large intestine could be observed in 28(96.6%).Coexisting lesions were observed in 22(78.6%)of these 28 patients.The lesions comprised adenomatous polyps in 17 patients(60.7%), synchronous colon cancers in 5 patients(17.9%), and obstructive colitis in 3 patients(10.7%), with some overlapping cases.All patients with multiple cancers underwent one-stage surgery, and all lesions were excised at the same time.Colonoscopy after colonic stent placement is important for preoperative diagnosis of coexisting lesions and planning the extent of resection. These considerations support the utility of colonic stenting for BTS.

  17. Respiratory support with venovenous extracorporeal membrane oxygenation during stent placement for the palliation of critical airway obstruction: case series analysis.

    Science.gov (United States)

    Park, Jung-Hoon; Shin, Ji Hoon; Kim, Kun Yung; Lim, Ju Yong; Kim, Pyeong Hwa; Tsauo, Jiaywei; Kim, Min Tae; Song, Ho-Young

    2017-08-01

    Venovenous extracorporeal membrane oxygenation (VV ECMO) is used to support gas transfer of patients suffering from respiratory failure during various procedures. The purpose of this study was to evaluate the technical feasibility and safety of fluoroscopic stent placement under respiratory support with VV ECMO in patients with critical airway obstructions. We reviewed the records of 17 patients (14 male and 3 female; mean age: 63 years; range, 30-82 years) who underwent self-expandable metallic stent (SEMS) placement under VV ECMO respiratory support for critical airway obstruction caused by malignant (n=16) or benign (n=1) etiology. Fluoroscopic placement of SEMS was successful in all patients (100%) with no procedure-related complications. During a mean follow-up of 83 days (range, 10-367 days), 15 (88.2%) of 17 patients showed improvement of Hugh-Jones grades (from 4.7±0.4 to 3.1±0.9, Pcritical airway obstruction, especially in cases of respiratory distress despite ventilation support and an inability to lie in a supine position. However, further studies will be needed to validate the standardized methods and specific indications.

  18. The treatment of complex airway diseases with inverted Y-shaped self-expandable metal stent

    International Nuclear Information System (INIS)

    Li Jianming; Jia Guangzhi

    2011-01-01

    Objective: To investigate the application and therapeutic effects of inverted Y-shaped self-expandable metal airway stent in treating complex airway diseases (stenosis or fistula). Methods: According to the distinctive anatomic structure and the pathological changes of complex airway stenosis or fistula, the inverted y-shaped self-expandable metal airway stent was designed. Under fluoroscopic monitoring, a total of 12 inverted Y-shaped self-expandable metal stents were implanted in 12 patients with complex airway diseases. Results: Stent placement in the trachea-bronchial tree was technically successful in all patients. After the operation, the symptom of dyspnea was immediately relieved and the bucking following food intake disappeared. The general physical condition and living quality were much improved in all patients. Conclusion: The use of inverted Y-shaped self-expandable metal airway stent for the management of complex airway stenosis involving the tracheal carina was a simple and safe procedure and it has satisfactory short-term clinical results. (authors)

  19. Coated metal stents installation for the treatment of malignant tumors complicated with colonic and rectal fistula

    International Nuclear Information System (INIS)

    Mao Aiwu; Fang Shiming; Liu Shiyi; Lin Qing; Jiang Haosheng; Jia Yiping; Gao Zhongdu

    2007-01-01

    Objective: To probe the clinical features of malignant colonic and rectal tumors together with coated metal stent placement. Methods: 24 cases of colonic fistula with late stage malignant tumors including 16 cases of intestinal cancer(66.7%), 2 cases of gastric and cervical cancers respectively(8.3%); 1 case of bladder, 1 case of prostate, 1 case of ovary and 1 case of gallbladder cancer(4.2%). The cause for the fistulas were direct invasion (37.5% )and radiotherapy (62.5%). The KPS was 30-60, and the median value was 40. CT were done preoperatively and followed by radiography of canulation contrast medium enema to ensure the location of the orifice of the fistula, the route of intestinal canal or complicated with obstruction and the condition with nearby tissues. Stents were finally implanted specifically according to the different situations of intestines. The sites of implanted stents and the occlusion of fistula should be strictly scrutinized; and then with careful follow up of patients complications and general condition. The procedure was carried out practically in 23 cases. Results: The successful rate of technique reached 96%(22/23), the failed one was due to the curve over sharpness of intestinal lock and resulting in non-expansion of the stent. The clinical successful rate was 91.3%. The two failed cased included the one with improper coherence to the intestinal wall leading to the stent migration and the other with a mild leakage after stent placement. The follow-up duration were 28-365 days, average 109 days, and the median value was 92 days. The average surviving period of 3 months and 6 months were 51% and 11% respectively. Conclusion: Intestinal fistula is the common complication after intestinal tumor operation and radiotherapy with poor prognosis. Metal covered stents provide a therapy of choice to improve the life quality and prolong the life span. (authors)

  20. Stent placement for palliation of cor triatriatum dexter in a dog with suspected patent foramen ovale.

    Science.gov (United States)

    Barncord, Kristin; Stauthammer, Christopher; Moen, Sean L; Hanson, Melissa; Gruenstein, Daniel H

    2016-03-01

    An 11 month old spayed, female dog presented with exercise intolerance and cyanosis upon exertion. Echocardiography revealed an imperforate cor triatriatum dexter with mild tricuspid valve dysplasia, an underfilled right ventricle and significant right to left shunting across a presumptive patent foramen ovale. Balloon dilation of the abnormal atrial membrane was initially successful in creating a communication between the right atrial chambers, but stenosis of the original perforation and persistent clinical signs prompted a second intervention. A balloon expandable biliary stent was placed across the abnormal partition, improving caudal venous return to the right ventricle and reducing the right to left shunt. Three months after stent placement, resting oxygen saturation had normalized. Six months after stent placement, exercise tolerance had improved and exertional cyanosis had resolved. Long term follow up will be necessary to assess for remodeling of the right ventricle with improved venous return. Stent placement can be considered as a palliative treatment option for cor triatriatum dexter, especially for stenosis post-balloon dilation. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Percutaneous transluminal angioplasty and stent placement for iliofemoral arterial atherosclerotic occlusive disease

    International Nuclear Information System (INIS)

    Zheng Yanbo; Jiang Wenjin; Liu Sheng; Song Xuepeng; Sheng Qirui

    2006-01-01

    Objectives: To assess the safety and efficacy of percutaneous transluminal angioplasty (PTA) and stent placement for the treatment of iliofemoral arterial atherosclerotic occlusive diseases. Methods From April 1999 to August 2004, 13 cases of iliofemoral arterial occlusions were recanalized with contact thrombolytic therapy combined with guide wire mechanical recanalization method, followed by angioplasty and stent placement. A total of 25 self-expanding Wallstents were deployed. All patients were followed up by means of duplex ultrasound, angiography, or both. Results: All 13 cases were successfully recanalized, with technical successful rate of 100%. Available follow-up for all patients from 8 months-5 years (mean 26.2 months) included one patient undergoing again with successful contact thrombolysis because of early thrombosis; another patient with recurrent symptoms at 19 month after operation undertaking surgical bypass because of later reocclusion; all of the rest stents showing patency by the end of the study. Conclusions: Contact thrombolysis combined with guide wire mechanical recanalization for iliofemoral arterial occlusion is safe and effective, whereas PTA and stent placement would have the nearly same efficacy for the disease with mild injury and low restenosis. (authors)

  2. A simple three-dimensional stent for proper placement of mini-implant

    OpenAIRE

    Felicita, A Sumathi

    2013-01-01

    Background This paper deals with the fabrication of a three-dimensional stent which is simple in design but provides an accurate placement of a mini-implant in three planes of space, namely, sagittal (root proximity), vertical (attached gingiva/alveolar mucosa) and transverse (angulation). Findings The stent is made of 0.018 × 0.025 in. stainless steel archwire which consists of a ‘u loop’ angulated at 20°, a vertical limb, a horizontal limb and a stop. The angulation of the ‘u’ helps in the ...

  3. Contralateral Deep Vein Thrombosis after Iliac Vein Stent Placement in Patients with May-Thurner Syndrome.

    Science.gov (United States)

    Le, Trong Binh; Lee, Taeg Ki; Park, Keun-Myoung; Jeon, Yong Sun; Hong, Kee Chun; Cho, Soon Gu

    2018-04-25

    To investigate the incidence and potential causes of contralateral deep vein thrombosis (DVT) after common iliac vein (CIV) stent placement in patients with May-Thurner syndrome (MTS). Data of 111 patients (women: 73%) who had CIV stent implantation for symptomatic MTS at a single center were retrospectively analyzed. Mean patient age was 63.1 ± 15.2 years. Median follow-up was 36 months (range, 1-142 months). Stent location was determined by venogram and classified as extended to the inferior vena cava (IVC), covered the confluence, or confined to the iliac vein. Potential causes of contralateral DVT were presumed based on venographic findings. The relationship between stent location and contralateral DVT was analyzed. Ten patients (9%, men/women: 4/6) exhibited contralateral DVT at a median timing of 40 months (range, 6-98 months). Median age was 69 years (range, 42-85 years). Median follow-up was 73.5 months (range, 20-134 months). Potential causes were venous intimal hyperplasia (VIH) (n = 7), "jailing" (n = 2), and indeterminate (n = 1). All patients with VIH had previous CIV stents overextended to the IVC. Overextension of CIV stent was associated with contralateral DVT (P VIH should be considered a potential cause. Copyright © 2018 SIR. Published by Elsevier Inc. All rights reserved.

  4. Stent placement in hemodialysis access: historical lessons, the state of the art and future directions.

    Science.gov (United States)

    Yevzlin, Alexander; Asif, Arif

    2009-05-01

    Vascular access stenosis in patients undergoing chronic hemodialysis is a major issue that is associated with increased morbidity, mortality, and cost of medical care. Recent data have emphasized that endovascular stents could be used in the treatment of central as well as peripheral stenotic lesions. In general, a peripheral or central vein lesion that is elastic or recurs within a three-month period after an initially successful balloon angioplasty or a stenosis where surgical revision is not possible are some indications for intravascular stent placement. Recent reports have expanded the role of stents in the management of pseudoaneurysms associated with dialysis access. In this context, the utilization of these devices must take into account a fair comparison with the traditional (surgical) approaches regarding effectiveness as well as costs. This report describes the role of stents in arteriovenous dialysis access. In addition, some of the recent advances in the structure and complicating issues such as stent fracture, migration, and infection, as well cannulation through the stent, are discussed.

  5. Placement of a Colonic Stent by Percutaneous Colostomy in a Case of Malignant Stenosis

    International Nuclear Information System (INIS)

    Gomez Herrero, Helena; Paul Diaz, Laura; Pinto Pabon, Isabel; Lobato Fernandez, Rosa

    2001-01-01

    We present a patient with disseminated stomach cancer who presented with symptoms of acute obstruction of the splenic flexure of the colon caused by tumor spread. During a first attempt to insert a colon stent through the anus under endoscopic guidance as final palliative therapy, it was not possible to reach the region of the stricture, and iatrogenic perforation of the descending colon occurred, which resolved favorably under conservative management. A second attempt to insert a stent was made via percutaneous puncture of the transverse colon, approaching the region of the stricture by a descending route. The procedure was completed without complications and the patient's symptoms improved. Stent placement via percutaneous puncture of the colon has not previously been described in the literature. It may be an alternate route in cases of proximal strictures in which access through the anus has been unsuccessful even with the aid of endoscopic guidance

  6. Loss of Renal Function After Retrograde Ureteral Placement of an Allium Stent for Severe Ureteral Stricture.

    Science.gov (United States)

    Salciccia, Stefano; Sciarra, Alessandro; Polese, Milena; Giorgio, Alpi; Maggi, Martina; Gentilucci, Alessandro; Ciccariello, Mauro; D'Eramo, Giuseppe; Shahabadi, Houssain; Lai, Silvia; Ricciuti, Gian Piero

    2018-01-01

    Background: Ureteral strictures are a recurrent chronic condition that leads to severe side effects and poor quality of life. Management of ureteral stricture is a great challenge for urologists and no specific guidelines exist. Retrograde Allium ® ureteral stent (AUS) is a newly developed ureteral stent to treat either bulbar urethral or ureteral stenosis. Case Presentation: We describe a case of a 74-year-old Caucasian adult male presenting with a severe ureteral stricture secondary to an ureteroscopy for stone disease. Treatment with retrograde AUS placement produced a complete loss of renal function after 36 months, probably because of the development of a long achalasic stretch of the ureter. Conclusions: AUS is a new and promising device for the treatment of ureteral stenosis. However, a lack of standardization of the technique recommends a close instrumental follow-up after the procedure to decide the optimal time for stent removal.

  7. Temporary placement of a paclitaxel or rapamycin-eluting stent is effective to reduce stenting induced inflammatory reaction and scaring in benign cardia stricture models.

    Science.gov (United States)

    Wang, Lin; Zhu, Yue-Qi; Cheng, Ying-Sheng; Cui, Wen-Guo; Chen, Ni-Wei

    2014-12-01

    To investigate whether temporary placement of a paclitaxel or rapamycin eluting stent is more effective to reduce stenting induced inflammatory reaction and scaring than a bared stent in benign cardia stricture models. Eighty dog models of stricture were randomly divided into a control group (CG, n=20, no stent insertion), a bare stent group (BSG, n=20), a paclitaxel eluting (Pacl-ESG, n=20) and a rapamycin eluting stent group (Rapa-ESG, n=20), with one-week stent retention. Lower-oesophageal-sphincter pressure (LOSP), 5-minute barium height (5-mBH) and cardia diameter were assessed before, immediately after the procedure, and regularly for 6 months. Five dogs in each group were euthanized for histological examination at each follow-up assessment. Stent insertion was well tolerated, with similar migration rates in three groups. At 6 months, LOSP and 5-mBH improved in Pacl-ESG and Rapa-ESG compared to BSG (p0.05). Cardia kept more patency in the Pacl-ESG and Rapa-ESG than in BSG (p0.05). Paclitaxel or rapamycin-eluting stents insertion led to better outcomes than bare stents in benign cardia stricture models.

  8. Anesthetic and Airways Management of a Dog with Severe Tracheal Collapse during Intraluminal Stent Placement

    Directory of Open Access Journals (Sweden)

    M. Argano

    2013-01-01

    Full Text Available This case report describes the anesthetic and airways management of a dog affected by 4th degree tracheal collapse and undergoing endoscope-guided intraluminal stent placement. After premedication with acepromazine and butorphanol, general anesthesia was induced with propofol and maintained with intravenous propofol and butorphanol in constant rate infusion. During intraluminal stent placement, oxygen was supplemented by means of a simple and inexpensive handmade device, namely, a ureteral catheter inserted into the trachea and connected to an oxygen source, which allowed for the maintenance of airways’ patency and adequate patient’s oxygenation, without decreasing visibility in the surgical field or interfering with the procedure. The use of the technique described in the present paper was the main determinant of the successful anesthetic management and may be proposed for similar critical cases in which surgical manipulation of the tracheal lumen, which may potentially result in hypoxia by compromising airways patency, is required.

  9. Head-mounted display for a personal integrated image monitoring system: ureteral stent placement.

    Science.gov (United States)

    Yoshida, Soichiro; Kihara, Kazunori; Takeshita, Hideki; Nakanishi, Yasukazu; Kijima, Toshiki; Ishioka, Junichiro; Matsuoka, Yoh; Numao, Noboru; Saito, Kazutaka; Fujii, Yasuhisa

    2015-01-01

    The personal head-mounted display (HMD) has emerged as a novel image monitoring system. We present here the application of a high-definition organic electroluminescent binocular HMD in ureteral stent placement. Our HMD system displayed multiple forms of information such as integrated, sharp, high-contrast images using a four-split screen or a picture-in-picture technique both seamlessly and synchronously. When both the operator and the assistant wore an HMD, they could continuously and simultaneously monitor the cystoscopic and fluoroscopic images in an ergonomically natural position. Furthermore, each participant was able to modulate the displayed images depending on the procedure. In all five cases, both the operator and the assistant successfully used this system with no unfavorable event. No participants experienced any HMD wear-related adverse effects. We therefore believe this HMD system might be potentially beneficial during ureteral stent placement procedures. Furthermore, it is compact, easily introduced and affordable. © 2014 S. Karger AG, Basel.

  10. Mesenteric artery complications during angioplasty and stent placement for atherosclerotic chronic mesenteric ischemia.

    Science.gov (United States)

    Oderich, Gustavo S; Tallarita, Tiziano; Gloviczki, Peter; Duncan, Audra A; Kalra, Manju; Misra, Sanjay; Cha, Stephen; Bower, Thomas C

    2012-04-01

    The purpose of this study was to describe the incidence, management, and outcomes of mesenteric artery complications (MACs) during angioplasty and stent placement (MAS) for chronic mesenteric ischemia (CMI). We retrospectively reviewed the clinical data of 156 patients treated with 173 MAS for CMI (1998-2010). MACs were defined as procedure-related mesenteric artery dissection, stent dislodgement, embolization, thrombosis, or perforation. End points were procedure-related morbidity and death. There were 113 women and 43 men (mean age, 73 ± 14 years). Eleven patients (7%) developed 14 MACs, including distal mesenteric embolization in six, branch perforation in three, dissection in two, stent dislodgement in two, and stent thrombosis in one. Five patients required adjunctive endovascular procedures, including in two patients each, catheter-directed thrombolysis or aspiration, retrieval of dislodged stents, and placement of additional stents for dissection. Five patients (45%) required conversion to open repair: two required evacuation of mesenteric hematoma, two required mesenteric revascularization, and one required bowel resection. There were four early deaths (2.5%) due to mesenteric embolization or myocardial infarction in two patients each. Patients with MACs had higher rates of mortality (18% vs 1.5%) and morbidity (64% vs 19%; P thrombosis (odds ratio, 0.2; 95% confidence interval, 0.06-0.90). Patients treated by a large-profile system had a trend toward more MACs (odds ratio, 1.8; 95% confidence interval, 0.7-26.5; P = .07). MACs occurred in 7% of patients who underwent MAS for CMI and resulted in higher mortality, morbidity, and longer hospital length of stay. Use of antiplatelet therapy reduced the risk of distal embolization or vessel thrombosis. There was a trend toward more MACs in patients who underwent interventions performed with a large-profile system. Copyright © 2012 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  11. A simple three-dimensional stent for proper placement of mini-implant.

    Science.gov (United States)

    Felicita, A Sumathi

    2013-11-12

    This paper deals with the fabrication of a three-dimensional stent which is simple in design but provides an accurate placement of a mini-implant in three planes of space, namely, sagittal (root proximity), vertical (attached gingiva/alveolar mucosa) and transverse (angulation). The stent is made of 0.018×0.025 in. stainless steel archwire which consists of a 'u loop' angulated at 20°, a vertical limb, a horizontal limb and a stop. The angulation of the 'u' helps in the placement of the mini-implant at 70° to the long axis of the tooth. The vertical height is determined such that the mini-implant is placed at the mucogingival junction. The mini-implant is placed with the aid of the stent, and its angulation and proximity to the adjacent roots are checked with a cone beam computed tomography image. The cone beam computed tomography image showed the mini-implant at an angle of 70° to the long axis of the tooth. There is no contact between mini-implant and the roots of the adjacent teeth. This stent is simple, easy to fabricate, cost-effective, and provides ease of insertion/removal, and three-dimensional orientation of the mini-implant.

  12. New expandable metallic stents: An experimental study in vessels of dogs

    International Nuclear Information System (INIS)

    Song, Ho Young; Lee, Jung Min; Chung, Jin Young; Chung, Gyung Ho; Kim, Bog Yi; Kuh, Ja Houng

    1992-01-01

    Three-types of expandable metallic stents were constructed to evaluate the differences between the stents: one, formed in a cylindrical zigzag pattern wth stainless steel wire (Gianturco stent), another, made by coating the Gianturco stent with silicone rubber (Silicone stent), the third, made by coating the Gianturco stent with 24 carat gold (Gold stent) for tissue acceptance. A total of 69 stents (each 23 stents of Gianturco, Silicone, and Gold stents) of 8-12 mm in diameter and 20 mm long were placed into normal abdominal aorta, inferior vena cava and lilac artery of nine adults dogs for 2 weeks to 11 months. It was more difficult to introduce Silicone stent into an introducing sheath than Gianturco or Gold stent due to the thickness of silicone rubber. Four Gianturco stents and three Silicone stents showed migration but Gold stent did not. Luminal narrowing or occlusion was noted in 3 Silicone stents. In 2 Gianturco stents, and in 1 Gold stent. Neointimal proliferation over the stent wires was more rapid and even in Gold stent than Silicone or Gianturco stent. Although further study is needed, Gold stent seems to be better than Gianturco or Silicone stent as an endovascular graft material

  13. Drug-eluting stents versus bare-metal stents for acute coronary syndrome

    DEFF Research Database (Denmark)

    Feinberg, Joshua; Nielsen, Emil Eik; Greenhalgh, Janette

    2017-01-01

    BACKGROUND: Approximately 3.7 million people died from acute coronary syndrome worldwide in 2012. Acute coronary syndrome, also known as myocardial infarction or unstable angina pectoris, is caused by a sudden blockage of the blood supplied to the heart muscle. Percutaneous coronary intervention...... CRITERIA: Randomised clinical trials assessing the effects of drug-eluting stents versus bare-metal stents for acute coronary syndrome. We included trials irrespective of publication type, status, date, or language. DATA COLLECTION AND ANALYSIS: We followed our published protocol and the methodological......-eluting stents group compared with 6.63% in the bare-metal stents group based on the RR of 0.96 (95% CI 0.83 to 1.11, 10,939 participants, 19 trials/20 comparisons, very low-quality evidence). The results of Trial Sequential Analysis showed that we did not have sufficient information to confirm or reject our...

  14. The operative cooperation and nursing in performing airway stent placement under DSA guidance for treating airway stenosis

    International Nuclear Information System (INIS)

    Yan Baojun; Wu Gang; Han Xinwei; Wang Nan; Shi Jin; Si Wenfeng; Wang Kai; Su Ning; Liu Jia; Hai Dandan

    2011-01-01

    Objective: To discuss the key points of the nursing care for effectively performing airway stent placement under DSA monitoring for airway stenosis. Methods: Corresponding nursing care measures were carried out for 118 patients with airway stenosis who were treated with airway stent placement. Results: The symptom of dyspnea was markedly relieved after stent implantation in all 118 patients with airway stenosis. Conclusion: To strengthen the preoperative psychological nursing and operative posture training, to make close postoperative watch on vital signs, to adopt some prevention measures for possible complications and to give necessary medical advises at the time of discharge are very helpful for patient's recovery after the surgery. (authors)

  15. Endoscopic management of pancreatic duct injury by endoscopic stent placement: a case report and literature review

    Directory of Open Access Journals (Sweden)

    Ito Yasuhiro

    2012-07-01

    Full Text Available Abstract Recently, the diagnostic evaluation of pancreatic injury has improved dramatically. On the other hand, it is occasionally difficult to diagnose pancreatic injury, because there are no specific signs, symptoms, or laboratory findings. Radiological imaging also often fails to identify pancreatic injury in the acute phase. Delayed diagnosis results in significant morbidity and mortality. Most cases of pancreatic injury with suspicion or pancreatic duct disruption require surgery. Endoscopic retrograde cholangiopancreatography is one of the most accurate modalities for ductal evaluation and therapy and might enable one to avoid unnecessary surgery. We describe endoscopic management of pancreatic duct injury by endoscopic stent placement. A 45-year-old woman was admitted after a traffic accident. A computed tomography scan showed pancreatic parenchyma disruption at the pancreatic head. Endoscopic retrograde cholangiopancreatography demonstrated disruption of the pancreatic duct with extravasation into the peripancreatic fluid collection. A 5-French endoscopic nasopancreatic drainage (ENPD tube was placed. Her symptoms dramatically improved. ENPD tube was exchanged for a 5-French 5-cm pancreatic stent. Subsequent follow-up CT revealed remarkable improvement. On the 26th day, the patient was discharged from the hospital without symptoms or complications. In this report, a pancreatic stent may lead to rapid clinical improvement and enable surgery to be avoided. On the other hand, the reported complications of long-term follow-up make the role of stenting uncertain. Thus, close attention should be paid to stenting management in the follow-up period. A pancreatic stent is useful for pancreatic ductal injury. If pancreatic ductal injury is managed appropriately, a pancreatic stent may improve the clinical condition, and also prevent unnecessary surgery.

  16. Self-expandable metallic stents for palliation of patients with malignant gastric outlet obstruction caused by stomach cancer

    Science.gov (United States)

    Kim, Tae Oh; Kang, Dae Hwan; Kim, Gwang Ha; Heo, Jeong; Song, Geun Am; Cho, Mong; Kim, Dong Heon; Sim, Mun Sup

    2007-01-01

    AIM: To ascertain clinical outcome and complications of self-expandable metal stents for endoscopic palliation of patients with malignant obstruction of the gastrointestinal (GI) tract. METHODS: A retrospective review was performed throughout August 2000 to June 2005 of 53 patients with gastric outlet obstruction caused by stomach cancer. All patients had symptomatic obstruction including nausea, vomiting, and decreased oral intake. All received self-expandable metallic stents. RESULTS: Stent implantation was successful in all 53 (100%) patients. Relief of obstructive symptoms was achieved in 43 (81.1%) patients. No immediate stent-related complications were noted. Seventeen patients had recurrent obstruction (tumor ingrowth in 14 patients, tumor overgrowth in 1 patient, and partial distal stent migration in 2 patients). The mean survival was 145 d. Median stent patency time was 187 d. CONCLUSION: Endoscopic placement of self-expandable metallic stents is a safe and effective treatment for the palliation of patients with inoperable malignant gastric outlet obstruction caused by stomach cancer. PMID:17352023

  17. Outcome of urethral stent placement for management of urethral obstruction secondary to transitional cell carcinoma in dogs: 19 cases (2007-2010).

    Science.gov (United States)

    McMillan, Sarah K; Knapp, Deborah W; Ramos-Vara, José A; Bonney, Patty L; Adams, Larry G

    2012-12-15

    To determine the outcome in dogs undergoing urethral stent placement for management of urethral obstruction secondary to transitional cell carcinoma (TCC). Retrospective case series. 19 dogs with histopathologically confirmed TCC. Information regarding urethral stent placement and follow-up treatment was obtained from review of medical records. Quality of life assessment was performed with an owner questionnaire. Self-expanding nitinol stents were successfully placed in 17 of 19 dogs; stent placement was not possible in one dog, and another dog was euthanatized 2 days after stent placement, but before discharge from the hospital. Median survival time in 17 dogs following successful long-term stent placement was 78 days (range, 2 to 366 days). Complications following stent placement in 18 dogs included incontinence (n = 7), reobstruction from continued growth of urethral TCC (3), acute reobstruction shortly after the procedure (1), and stent migration (2). Of the 17 owners surveyed, 16 were satisfied with the outcome and would recommend urethral stent placement. The placement of self-expanding nitinol urethral stents was successful in alleviating TCC-induced urethral obstruction and providing good quality of life for most dogs.

  18. Endoscopic placement of double-J ureteric stents in children as a treatment for primary obstructive megaureter

    Directory of Open Access Journals (Sweden)

    Carroll Daniel

    2010-01-01

    Full Text Available Aim: To determine the efficacy and potential complications of double-J ureteric stents in the treatment of persistent or progressive primary obstructive megaureter in pediatric patients within our institution. Materials and Methods: A retrospective case-note review of all patients with double-J ureteric stents, between 1997 and 2004, was performed. In all, 38 stents were inserted in 31 patients aged between 2 months and 15 years of age. Complications and results of follow-up investigations and the need for follow-up investigations were recorded. Patients were followed up clinically and radiologically for a minimum of 2 years following stent insertion. Results: Endoscopic placement of double-J ureteric stents in childhood is straightforward and complications are uncommon (8/38 insertions. In non-resolving or progressive primary non-refluxing megaureter, double-J ureteric stenting alone is effective with resolution of primary non-refluxing megaureter in 66% of cases (25/38 insertions. Conclusions: Ureteric stenting provides an alternative to early surgery in patients with primary non-refluxing megaureter. The youngest patient in our series was 2 months old at the time of endoscopic ureteric double-J stent insertion. Endoscopic placement of ureteric double-J stents should be considered as a first-line treatment in the management of persistent or progressive non-refluxing megaureter leading to progressive hydronephrosis or pyonephrosis.

  19. Temporary placement of covered retrievable expandable nitinol stents with barbs in high-risk surgical patients with benign prostatic hyperplasia: work in progress.

    Science.gov (United States)

    Kim, Choung-Soo; Song, Ho-Young; Jeong, In Gab; Yeo, Hyun Jin; Kim, Eun-Young; Park, Jung-Hoon; Yoon, Chang Jin; Paick, Sung Hyun; Park, Sang Woo; Bae, Jae-Ik; Won, Je Hwan

    2011-10-01

    To report the use of a newly constructed, covered, retrievable, expandable nitinol stent with barbs to overcome the problem of stent migration associated with conventional covered prostatic expandable stents and to evaluate prospectively the technical feasibility and clinical effectiveness of the stents in patients with benign prostatic hyperplasia (BPH). A covered retrievable expandable nitinol stent with four barbs was placed with use of an 18-F stent delivery system in seven consecutive patients with symptomatic BPH who had high operative risks. Age range of patients was 62-83 years (mean 74 years). In cases in which the stent migrated, it was replaced with a stent with eight barbs. The stents were routinely removed 4 months after placement using a 21-F stent removal set. Stent placement was technically successful and well tolerated in six of the seven patients. The remaining patient needed a second stent placement after removal of the first stent. The stent with four barbs migrated into the urinary bladder in four patients (57%); three of these patients received a second stent with eight barbs with good results, and the fourth patient did not need further treatment because his symptoms improved. Routine removal of the stent 4 months after placement was performed in three of the seven patients with good results. Retrievable stents with eight barbs seem to overcome the problem of stent migration associated with conventional prostatic expandable stents. Preliminary results suggest that stents with barbs are both feasible and effective in patients with BPH. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.

  20. Safety and Efficacy of Percutaneous Biliary Covered Stent Placement in Patients with Malignant Biliary Hilar Obstruction; Correlation with Liver Function

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, Hyeran; Choi, Sun Young, E-mail: medmath@hanmail.net [School of Medicine Ewha Womans University, Department of Radiology and Medical Research Institute (Korea, Republic of); Kim, Kyung Ah [St. Vincent’s Hospital, The Catholic University of Korea, Department of Radiology (Korea, Republic of); Ko, Soo Bin [College of Arts and Science Case Western Reserve University, Department of Biology (United States)

    2016-09-15

    PurposeTo estimate the safety and efficacy of percutaneous ePTFE-covered biliary stent placement and the relationship between underlying liver function and stent patency in patients with malignant hilar obstruction.Materials and MethodsFrom March 2012 to June 2015, 41 patients [22 females, 19 males; mean age 69.8 (range 34–94) years] with malignant biliary obstruction underwent percutaneous biliary stent placement (31 patients with unilateral, 10 patients with bilateral side-by-side). Cumulative patient survival and stent patency rate curves were derived using the Kaplan–Meier method. A Cox model was used to explore the relationship between liver function and patient survival, and also biliary stent patency. Pearson correlation coefficient was used to analyze the relationship between patient survival and stent patency.ResultsTechnical success rate was 100 % and clinical success rate was 95 %. During follow-up, four complications occurred (two bilomas and two cases of acute cholecystitis) and were treated successfully with percutaneous drainage. No other complication occurred. Mean serum bilirubin level was 11.34 ± 7.35 mg/dL before drainage and 5.00 ± 4.83 mg/dL 2 weeks after stent placement. The median patent survival duration was 147 days (95 % CI, 69.6–224.4 days). The median stent patency duration was 101 days (95 % CI, 70.0–132.0 days). The cumulative stent patency rates at 1, 3, 6, and 12 months were 97, 57.6, 30.3, and 17.0 %, respectively. Child–Pugh score was correlated significantly with patient survival (P = 0.011) and stent patency (P = 0.007). MELD score was correlated significantly with stent patency (P = 0.044). There was a correlation between patient survival and stent patency (r = 0.778, P < 0.001).ConclusionPercutaneous placement of ePTFE-covered biliary stent was a safe and an effective method for malignant biliary obstruction. Underlying liver function seemed to be one of the important factors affecting

  1. [Short term effect of multiple stents parallel placement and reconstruction technique for the treatment of giant fusiform vertebrobasilar dissecting aneurysms].

    Science.gov (United States)

    Li, Baomin; Liang, Yongping; Liu, Xinfeng; Wang, Jun; Li, Sheng; Cao, Xiangyu; Ge, Aili; Feng, Huimin

    2015-08-01

    To investigate the feasibility,safety and follow-up results of multiple stents parallel placement and reconstruction technique for treating giant vertebrobasilar dissecting aneurysms. Five consecutive patients with giant fusiform vertebrobasilar dissecting aneurysms in Department of Neurology,Chinese People's Liberation Army General Hospital were retrospectively reviewed from April 2011 to October 2013. All patients were diagnosed vertebrobasilar dissecting aneurysms by MRI and digital subtraction angiography (DSA), the aneurysm size ranged 8.2-15.0 mm. All patients were treated by multiple stents parallel placement and reconstruction technique under general anesthesia. In the endovascular treatment process, 2-3 Solitaire or Neuroform self-expandable stents were parallel implanted in the maximum extension segment of the aneurysms to reconstruct the cavity of the aneurysm and solved the problem that the diameter of the intracranial stent is less than the diameter of the aneurysms. Multiple stents parallel placement can keep the stents stable in the cavity. The parallel stent can close the dissection as well as strengthen the aneurysm walls to alleviate the vessel pulsative compression of the brain stem. Furthermore, one of the parallel stents was selected for the main blood flow channel. Based on the main channel, telescope technique was used to completely covering the dissection. It can not only prevent the progress of dissection to normal regions, but also be helpful for blood flow channel reconstruction to reduce the hemodynamic disorders. All Patients received routine antiplatelet therapy before and after endovascular treatment. The operative procedures were succeeded in all patients. Five patients were implanted 18 stents (3 stents in 3 patients; 4 stents in 1 patient; 5 stents in 1 patient; parallel 3 stents in 2 patients; parallel 2 stents in 3 patients). The signs and symptoms of brain stem and posterior group of cranial nerves improved significantly. All

  2. Stent under-expansion on the procedure day, a predictive factor for poor oral intake after metallic stenting for gastric outlet obstruction.

    Science.gov (United States)

    Hori, Yasuki; Naitoh, Itaru; Ban, Tesshin; Narita, Kei; Nakazawa, Takahiro; Hayashi, Kazuki; Miyabe, Katsuyuki; Shimizu, Shuya; Kondo, Hiromu; Nishi, Yuji; Yoshida, Michihiro; Umemura, Shuichiro; Kato, Akihisa; Yamada, Tomonori; Ando, Tomoaki; Joh, Takashi

    2015-08-01

    Self-expandable metallic stents (SEMS) have been widely accepted as palliation therapy for malignant gastric outlet obstruction (GOO). However, the factors predictive of poor oral intake after SEMS placement have not been elucidated sufficiently. We aimed to clarify both the patient and stent-related predictive factors. We retrospectively reviewed 126 consecutive patients who underwent uncovered SEMS placement for malignant GOO between April 2010 and March 2013 at a university hospital and two tertiary care referral centers. Technical success of SEMS placement was achieved in all 126 (100%) patients. Improved oral intake was observed in 111 (88.1%) patients. A Karnofsky performance status ≤ 40 (odds ratio [OR], 1.19; 95% confidence interval [CI], 1.02-1.28; P = 0.041), peritoneal dissemination (OR, 1.20; 95% CI, 1.01-1.26; P = 0.038), and under-expansion of the SEMS on the procedure day (OR, 1.55; 95% CI, 1.26-1.62; P < 0.001) were independent predictive factors for poor improvement on the GOO scoring system, according to multivariate analysis. SEMS under-expansion was a stent related, while poor performance status and peritoneal dissemination were patient related, predictive factors for poor oral intake after SEMS placement for malignant GOO. © 2015 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  3. Retrograde placement of double-J ureteral stent with interventional therapy for the treatment of ureteral stricture

    International Nuclear Information System (INIS)

    Kong Jian; Xu Linfeng; Liang Huimin; Zheng Chuansheng; Zheng Jinlong; Feng Gansheng

    2000-01-01

    Objective: To evaluate the retrograde placement of Double-J ureteral stent with interventional therapy for the treatment of ureteral stricture. Methods: Twenty patients with ureteral stricture of various causes were treated with retrograde placing Double-J ureteral stent by interventional therapy. Results: The Double-J stent was successfully performed in all twenty patients. The successful rate of placing stent was 100%. The cure rate was 90% (18/20). The complications such as urinary leakage, wound infection, and bleeding were markedly decreased. The indication, duration of indwelling and complication of the indwelling stent were discussed. Conclusion: Retrograde placing Double-J stent with interventional therapy is simple and less invasive. It is believed to be a safe and effective method for the treatment of ureteral stricture

  4. Current status of metal stents for managing malignant ureteric obstruction.

    Science.gov (United States)

    Sountoulides, Petros; Kaplan, Adam; Kaufmann, Oskar Grau; Sofikitis, Nikolaos

    2010-04-01

    Obstruction of the ureters caused by extrinsic compression from a primary tumour or retroperitoneal lymph node masses is not unusual in the course of advanced pelvic malignancies. Most of the cases are of gynaecological or gastrointestinal origin, and the situation can be aggravated by peri-ureteric fibrosis, a long-term adverse event of previous chemotherapy or radiotherapy. Undoubtedly upper urinary tract decompression and maintenance of ureteric patency, even as a palliative measure, is important in managing these patients. Options for upper tract decompression include percutaneous nephrostomy, retrograde stenting and open urinary diversion. Plastic stents have long been used for managing malignant ureteric obstruction, but their overall success remains limited. Plastic stents often fail to be placed correctly, require regular exchange, and are faced with a high incidence of encrustation and migration. For these reasons plastic stents have been unsuccessful for long-term maintenance of ureteric patency. To overcome these limitations metal stents were introduced and recently developed in an effort to ensure better long-term patency of the obstructed ureter, fewer hospital admissions for stent change and better overall quality of life. In the present review the clinical applications of different types of metal stents are discussed, with a specific focus on the latest advances and the future options for managing malignant ureteric obstruction. © 2010 THE AUTHORS. JOURNAL COMPILATION © 2010 BJU INTERNATIONAL.

  5. Endoscopic suture fixation is associated with reduced migration of esophageal fully covered self-expandable metal stents (FCSEMS).

    Science.gov (United States)

    Wright, Andrew; Chang, Andrew; Bedi, Aarti Oza; Wamsteker, Erik-Jan; Elta, Grace; Kwon, Richard S; Carrott, Phillip; Elmunzer, B Joseph; Law, Ryan

    2017-09-01

    Esophageal fully covered self-expandable metal stents (FCSEMS) are indicated for the management of benign and malignant conditions of the esophagus including perforations, leaks, and strictures. FCSEMS are resistant to tissue ingrowth and are removable; however, stent migration occurs in 30-55% of cases. Endoscopic suture fixation of FCSEMS has been utilized to decrease the risk of stent migration though data supporting this practice remain limited. The primary aim of this study was to compare clinical outcomes and migration rate of patients who underwent placement of esophageal FCSEMS with and without endoscopic suture fixation. Our single-center, retrospective, cohort study includes patients who underwent esophageal FCSEMS placement with and without endoscopic suture fixation between January 1, 2012, and November 11, 2015. Baseline patient characteristics, procedural details, and clinical outcomes were abstracted. Logistic regression was performed to identify clinical and technical factors associated with outcomes and stent migration. A total of 51 patients underwent 62 FCSEMS placements, including 21 procedures with endoscopic suture fixation and 41 without. Suture fixation was associated with reduced risk of stent migration (OR 0.13, 95% CI 0.03-0.47). Prior stent migration was associated with significantly higher risk of subsequent migration (OR 6.4, 95% CI 1.6-26.0). Stent migration was associated with lower likelihood of clinical success (OR 0.21, 95% CI 0.06-0.69). There was a trend toward higher clinical success among patients undergoing suture fixation (85.7 vs. 60.9%, p = 0.07). Endoscopic suture fixation of FCSEMS was associated with a reduced stent migration rate. Appropriate patient selection for suture fixation of FCSEMS may lead to reduced migration in high-risk patients.

  6. Endovascular tubular stent-graft placement for isolated iliac artery aneurysms.

    Science.gov (United States)

    Okada, Takuya; Yamaguchi, Masato; Kitagawa, Atsushi; Kawasaki, Ryota; Nomura, Yoshikatsu; Okita, Yutaka; Sugimura, Kazuro; Sugimoto, Koji

    2012-02-01

    To evaluate the safety, efficacy, and mid-term outcomes of endovascular tubular stent-graft placement for repair of isolated iliac artery aneurysms (IAAs). Between January 2002 and March 2010, 20 patients (7 women and 13 men; mean age 74 years) underwent endovascular repair of 22 isolated IAAs. Two patients underwent endovascular repair for bilateral aneurysms. Ten para-anastomotic aneurysms (45%) developed after open abdominal aortic aneurysm (AAA) repair with an aorto-iliac graft, and 12 were true aneurysms (55%). Eleven straight and 11 tapered stent-grafts were placed. Contrast-enhanced computed tomography (CT) was performed to detect complications and evaluate aneurysmal shrinkage at week 1, 3, 6, and 12 months and once every year thereafter. Non-contrast-enhanced CT was performed in seven patients with chronic kidney disease. All procedures were successful, without serious complications, during the mean (range) follow-up period of 746 days (47-2651). Type II endoleak not requiring treatment was noted in one patient. The mean (SD) diameters of the true and para-anastomotic aneurysms significantly (p IAAs is safe and efficacious. Tapered stent-grafts of various sizes are required for accurate placement.

  7. Covered self-expandable metal stents in pancreatic malignancy regardless of resectability: a new concept validated by a decision analysis.

    Science.gov (United States)

    Kahaleh, M; Brock, A; Conaway, M R; Shami, V M; Dumonceau, J M; Northup, P G; Tokar, J; Rich, T A; Adams, R B; Yeaton, P

    2007-04-01

    The current treatment model for the management of malignant biliary obstruction is to place a plastic stent for unstaged pancreatic cancer. In patients with unresectable disease but a life expectancy of more than 6 months, self-expandable metal stents (SEMS) are favored because of their more prolonged patency. We analyzed the efficacy and cost-effectiveness of covered SEMS (CSEMS) in patients with pancreatic cancer and distal biliary obstruction without regard to surgical resectability. Between March 2001 and March 2005, 101 consecutive patients with obstructive jaundice secondary to pancreatic cancer underwent placement of a CSEMS. Patients with resectable tumor were offered pancreaticoduodenectomy. A model was developed to compare the costs of CSEMS and polyethylene and DoubleLayer stents. A total of 21 patients underwent staging laparoscopy, of whom 16 had a resection (76%). The 85 patients who did not have a resection had a mean survival of 5.9 months (range 1-25 months) and a mean CSEMS patency duration of 5.5 months (range 1-16 months). Life-table analysis demonstrated CSEMS patency rates of 97% at 3 months, 85% at 6 months, and 68% at 12 months. In a cost model that accounted for polyethylene and DoubleLayer stent malfunction and surgical resections, initial CSEMS placement (3177 euros per patient) was a less costly intervention than either DoubleLayer stent placement (3224 euros per patient) or polyethylene stent placement with revision (3570 euros per patient). Covered SEMS are an effective treatment for distal biliary obstructions caused by pancreatic carcinoma. Their prolonged patency and removability makes them an attractive option for biliary decompression, regardless of resectability. The strategy of initial covered SEMS placement might be the most cost-effective strategy in these patients.

  8. Management of acute malignant colorectal obstruction with a novel self-expanding metallic stent as a bridge to surgery

    International Nuclear Information System (INIS)

    Li Yongdong; Cheng Yingsheng; Li Minghua; Fan Youben; Chen Niwei; Wang Yu; Zhao Jungong

    2010-01-01

    Purpose: To prospectively evaluate the safety and clinical efficacy of a newly designed self-expandable metallic stent (SEMS) in the treatment of patients with acute malignant colorectal obstruction. Methods: Between April 2001 and October 2007, 52 patients with acute malignant colorectal obstruction were treated with a new designed SEMS as an investigational bridge to surgery. Patients were prospectively followed and relevant data collection was collected, including details regarding technique, clinical symptoms, complications, need for elective surgery, and overall survival. Results: Stent placement was technically successful in all but two patients (due to complete obstruction) with no procedure-related complications. Complications included stent migration (n = 4), anal pain (n = 2) and stool impaction (n = 1). Clinical success was achieved in 49 (98%) of 50 patients with resolution of bowel obstruction within 2 days of stent placement. In one patient with stool impaction 2 days after stent placement, endoscopic disimpaction was successfully performed. An elective one-stage surgical procedure was performed in all 50 patients who successfully received a SEMS as a bridge to surgery within a mean of 8 ± 2 days (range: 4-11 days) after stent placement. Mean follow-up time was 36 ± 12 months (range 3-70 months), and all patients remained alive at the time of this report. Conclusion: The newly designed SEMS placement as a bridge to surgery was a safe and effective intervention for colonic decompression in patients with acute malignant colorectal obstruction and allowed a high proportion of patients to be successfully proceeded to elective surgery.

  9. Self-Expandable Stent Placement in Infrapopliteal Arteries After Unsuccessful Angioplasty Failure: One-Year Follow-up

    International Nuclear Information System (INIS)

    Peregrin, J. H.; Smirova, S.; Koznar, B.; Novotny, J.; Kovac, J.; Lastovickova, J.; Skibova, J.

    2008-01-01

    The purpose of this prospective study was to evaluate whether stent placement in infrapopliteal arteries is helpful in failed percutaneous transluminal angioplasty (PTA). Infrapopliteal PTA was performed in 70 arteries of 66 patients with chronic critical lower limb ischemia. The group comprised 55 males and 11 females, with an average age of 63.4 (range, 42-82) years. Diabetes mellitus was present in 92.4% of patients. Only the palpable anterior tibial and posterior tibial arteries were evaluated. Stents (Xpert stent; Abbot Vascular, Redwood City, CA, USA) were placed in 16 arteries where PTA was not successful (the failure was defined as residual stenosis >30% after PTA). In 54 arteries simple PTA was performed and was technically successful. Twenty-four nondilated arteries with no significant stenosis served as a comparison group. The 12-month patency rate was evaluated according to a combination of palpation and Doppler ultrasound. In all cases stent placement restored the flow in the artery immediately after unsuccessful PTA. Twelve-month follow-up showed a patency rate of 82% in the PTA group, 78% in the stent group, and 69% in the comparison group. We conclude that stent placement in the case of unsuccessful infrapopliteal PTA changed technical failure to success and restored flow in the dilated artery. At 12-month follow-up the patency rate of infrapopliteal arteries stented for PTA failure did not differ significantly either from nonstented arteries with an optimal PTA result or from a comparison group of nonintervened arteries.

  10. Stent migration following endoscopic suture fixation of esophageal self-expandable metal stents: a systematic review and meta-analysis.

    Science.gov (United States)

    Law, Ryan; Prabhu, Anoop; Fujii-Lau, Larissa; Shannon, Carol; Singh, Siddharth

    2018-02-01

    Covered self-expandable metal stents (SEMS) are utilized for the management of benign and malignant esophageal conditions; however, covered SEMS are prone to migration. Endoscopic suture fixation may mitigate the migration risk of covered esophageal SEMS. Hence, we conducted a systematic review and meta-analysis to evaluate the effectiveness and safety of endoscopic suture fixation for covered esophageal SEMS. Following PRISMA guidelines, we performed a systematic review from 2011 to 2016 to identify studies (case control/case series) reporting the technical success and migration rate of covered esophageal SEMS following endoscopic suture fixation. We searched multiple electronic databases and conference proceedings. We calculated pooled rates (and 95% confidence intervals [CI]) of technical success and stent migration using a random effects model. We identified 14 studies (212 patients) describing covered esophageal SEMS placement with endoscopic suture fixation. When reported, SEMS indications included leak/fistula (n = 75), stricture (n = 65), perforation (n = 10), and achalasia (n = 4). The pooled technical success rate was 96.7% (95% CI 92.3-98.6), without heterogeneity (I 2  = 0%). We identified 29 SEMS migrations at rate of 15.9% (95% CI 11.4-21.6), without heterogeneity (I 2  = 0%). Publication bias was observed, and using the trim-and-fill method, a more conservative estimate for stent migration was 17.0%. Suture-related adverse events were estimated to occur in 3.7% (95% CI 1.6-8.2) of cases. Endoscopic suture fixation of covered esophageal SEMS appears to reduce stent migration when compared to published rates of non-anchored SEMS. However, SEMS migration still occurs in approximately 1 out of 6 cases despite excellent immediate technical success and low risk of suture-related adverse events.

  11. Mechanical Properties of Metallic Stents: How Do These Properties Influence the Choice of Stent for Specific Lesions?

    International Nuclear Information System (INIS)

    Dyet, John F.; Watts, William G.; Ettles, Duncan F.; Nicholson, Anthony A.

    2000-01-01

    Purpose: To assess selected balloon-expandable and self-expanding stents for radial force, flexibility, radio-opacity, and trackability, and to relate these physical characteristics to potential indications for placement.Methods: Force-strain curves were plotted for each stent and the force required to produce 50% luminal narrowing was recorded. The ability of the stent to show elastic recoil following deformation was also noted. Flexibility was measured by bending the stents against a force transducer and recording the force required per degree of flexion. Radio-opacity was measured by comparing each stent against a standard aluminum step wedge. Trackability was measured by testing the ability of the stent on its delivery system to track over angles of 90 deg. and 60 deg. Results: The balloon-expandable stents showed greater radial strength and radio-opacity but, apart from the AVE Iliac Bridge stent, showed poorer flexibility and trackability. The self-expanding stents showed less radial force but were able to re-expand following deformity. They were generally more flexible and had better trackability but lower radio-opacity.Conclusion: There is no stent which exhibits all the ideal properties required and therefore the interventionist will need to keep a range of stents available if all lesions are to be addressed

  12. A Novel Partially Covered Self-Expandable Metallic Stent with Proximal Flare in Patients with Malignant Gastric Outlet Obstruction.

    Science.gov (United States)

    Takahara, Naminatsu; Isayama, Hiroyuki; Nakai, Yousuke; Yoshida, Shuntaro; Saito, Tomotaka; Mizuno, Suguru; Yagioka, Hiroshi; Kogure, Hirofumi; Togawa, Osamu; Matsubara, Saburo; Ito, Yukiko; Yamamoto, Natsuyo; Tada, Minoru; Koike, Kazuhiko

    2017-07-15

    Endoscopic placement of self-expandable metal stents (SEMSs) has emerged as a palliative treatment for malignant gastric outlet obstruction (GOO). Although covered SEMSs can prevent tumor ingrowth, frequent migration of covered SEMSs may offset their advantages in preventing tumor ingrowth. We conducted this multicenter, single-arm, retrospective study at six tertiary referral centers to evaluate the safety and efficacy of a partially covered SEMS with an uncovered large-bore flare at the proximal end as an antimigration system in 41 patients with symptomatic malignant GOO. The primary outcome was clinical success, and the secondary outcomes were technical success, stent dysfunction, adverse events, and survival after stent placement. The technical and clinical success rates were 100% and 95%, respectively. Stent dysfunctions occurred in 17 patients (41%), including stent migration in nine (23%), tumor ingrowth in one (2%), and tumor overgrowth in four (10%). Two patients (5%) developed adverse events: one pancreatitis and one perforation. No procedure-related death was observed. A novel partially covered SEMS with a large-bore flare proximal end was safe and effective for malignant GOO but failed to prevent stent migration. Further research is warranted to develop a covered SEMS with an optimal antimigration system.

  13. Metallic stent in the treatment of ureteral obstruction: Experience of single institute

    Directory of Open Access Journals (Sweden)

    Chien-Chang Li

    2011-10-01

    Conclusion: Patients with ureteral obstructions can be treated sufficiently with the Resonance® metallic stent. Patients who had gynecological malignancies and received radiotherapy had a higher failure rate after Resonance® metallic stent insertion.

  14. Why Vascular Surgeons and Interventional Radiologists Collaborate or Compete: A Look at Endovascular Stent Placements

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Eric J.; Collins, Jeremy D. [Northwestern University Feinberg School of Medicine, Department of Radiology (United States); Crowley-Matoka, Megan [Northwestern University Feinberg School of Medicine, Center for Bioethics and Medical Humanities (United States); Chrisman, Howard B. [Northwestern University Feinberg School of Medicine, Department of Radiology (United States); Milad, Magdy P. [Northwestern University Feinberg School of Medicine, Department of Obstetrics and Gynecology-Reproductive Endocrinology and Infertility (United States); Vogelzang, Robert L., E-mail: vogelzang@northwestern.edu [Northwestern University Feinberg School of Medicine, Department of Radiology (United States)

    2017-06-15

    PurposeTo understand how cultural differences between vascular surgeons (VSs) and interventional radiologists (IRs) affect their clinical decision making and inter-specialty relationships.MethodsTwenty-four conversational interviews were conducted with IRs and VSs about their approaches to patient care, views of their specialty and others, and solutions to any expressed concerns. Interview transcripts were systematically analyzed to identify and compare key themes according to the constructivist grounded theory and content analysis using NVivo 10 software. These data were supplemented with a retrospective analysis of 3658 endovascular stent placements performed at a large medical academic center over 11 years. Aggregate counts were divided by provider specialty, and trends were assessed via correlation coefficients.ResultsEndovascular stent placements were relatively equally divided between IR and VS over 11 years with some variability from placements by cardiology. IRs tend to lay claim to treatments as masters of procedures, whereas VSs base their claims on being masters of the treated diseases, leading to collaboration in some practices and bitter competition in others. The level of perceived competition was most associated with specialists’ awareness of and appreciation for specialty-specific values rather than differences in practice structure/reimbursement.ConclusionsUnderstanding cultural differences between IRs and VSs is imperative for fostering better collaboration to grow shared territory rather than competing for the same slice of the pie.

  15. Why Vascular Surgeons and Interventional Radiologists Collaborate or Compete: A Look at Endovascular Stent Placements

    International Nuclear Information System (INIS)

    Keller, Eric J.; Collins, Jeremy D.; Crowley-Matoka, Megan; Chrisman, Howard B.; Milad, Magdy P.; Vogelzang, Robert L.

    2017-01-01

    PurposeTo understand how cultural differences between vascular surgeons (VSs) and interventional radiologists (IRs) affect their clinical decision making and inter-specialty relationships.MethodsTwenty-four conversational interviews were conducted with IRs and VSs about their approaches to patient care, views of their specialty and others, and solutions to any expressed concerns. Interview transcripts were systematically analyzed to identify and compare key themes according to the constructivist grounded theory and content analysis using NVivo 10 software. These data were supplemented with a retrospective analysis of 3658 endovascular stent placements performed at a large medical academic center over 11 years. Aggregate counts were divided by provider specialty, and trends were assessed via correlation coefficients.ResultsEndovascular stent placements were relatively equally divided between IR and VS over 11 years with some variability from placements by cardiology. IRs tend to lay claim to treatments as masters of procedures, whereas VSs base their claims on being masters of the treated diseases, leading to collaboration in some practices and bitter competition in others. The level of perceived competition was most associated with specialists’ awareness of and appreciation for specialty-specific values rather than differences in practice structure/reimbursement.ConclusionsUnderstanding cultural differences between IRs and VSs is imperative for fostering better collaboration to grow shared territory rather than competing for the same slice of the pie.

  16. Management of malignant biliary obstruction: Technical and clinical results using an expanded polytetrafluoroethylene fluorinated ethylene propylene (ePTFE/FEP)-covered metallic stent after 6-year experience

    Energy Technology Data Exchange (ETDEWEB)

    Fanelli, Fabrizio; Orgera, Gianluigi; Bezzi, Mario; Rossi, Plinio; Allegritti, Massimiliano; Passariello, Roberto [University of Rome, Department of Radiological Sciences, Rome (Italy)

    2008-05-15

    To evaluate the efficacy and safety of an expanded polytetrafluoroethylene-fluorinated ethylene-propylene (ePTFE/FEP)-covered metallic stent in the management of malignant biliary obstruction. Eighty consecutive patients with malignant common bile duct strictures were treated by placement of 83 covered metallic stents. The stent-graft consists of an inner ePTFE/FEP lining and an outer supporting structure of nitinol wire. Clinical evaluation, assessment of serum bilirubin and liver enzyme levels were analyzed before biliary drainage, before stent-graft placement and during the follow-up period at 1, 3, 6, 9 and 12 months. Technical success was obtained in all cases. After a mean follow-up of 6.9{+-}4.63 months, the 30-day mortality rate was 14.2%. Survival rates were 40% and 20.2% at 6 and 12 months, respectively. Stent-graft patency rates were 95.5%, 92.6% and 85.7% at 3, 6 and 12 months, respectively. Complications occurred in five patients (6.4%); among these, acute cholecystitis was observed in three patients (3.8%). A stent-graft occlusion rate of 9% was observed. The percentage of patients undergoing lifetime palliation (91%) and the midterm patency rate suggest that placement of this ePTFE/FEP-covered stent-graft is safe and highly effective in achieving biliary drainage in patients with malignant strictures of the common bile duct. (orig.)

  17. Safety and efficacy of everolimus-eluting stents for bare-metal in-stent restenosis

    International Nuclear Information System (INIS)

    Ota, Hideaki; Mahmoudi, Michael; Torguson, Rebecca; Satler, Lowell F.; Suddath, William O.; Pichard, Augusto D.; Waksman, Ron

    2015-01-01

    Objective: The aim of this study was to compare the safety and efficacy of the everolimus-eluting stents (EES) with the paclitaxel-eluting stent (PES) and sirolimus-eluting stent (SES) for the treatment of bare-metal in-stent restenosis. Background: The optimal treatment for bare-metal in-stent restenosis remains controversial. Methods: The study cohort comprised 322 consecutive patients (543 lesions) who presented with bare-metal in-stent restenosis to our institution and underwent coronary artery stent implantation with EES (114 patients; 181 lesions), PES (65 patients; 116 lesions) and SES (143 patients; 246 lesions). The analyzed clinical parameters were the 1-year rates of death, Q-wave myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), definite stent thrombosis (ST) and major adverse cardiac events (MACE) defined as the composite of death, MI, or TLR at 1-year. Results: The three groups were well matched for the conventional risk factors except for age and chronic kidney disease. The 1-year analyzed clinical parameters were similar in the three groups: death (EES = 3.5%, PES = 4.6%, SES = 4.2%; p = 0.94), MI (EES = 3.5%, PES = 6.3%, SES = 2.1%; p = 0.31), TLR (EES = 9.8%, PES = 9.5%, SES = 5.7%; p = 0.42), TVR (EES = 14.3%, PES = 11.1%, SES = 11.3%; p = 0.74), definite ST (EES = 0.9%, PES = 3.1%, SES = 3.5%; p = 0.38) and MACE (EES = 14.0%, PES = 15.4%, SES = 10.5%; p = 0.54). Male gender (hazard ratio = 0.47; 95% confidence interval = 0.25–0.88) and number of treated lesions (hazard ratio = 1.47; 95% confidence interval = 1.06–2.05) were found to be independent predictors of MACE. Conclusion: The results of the present study indicate that EES may provide similar safety and efficacy as first generation DES for the treatment of patients presenting with bare-metal in-stent restenosis

  18. Safety and efficacy of everolimus-eluting stents for bare-metal in-stent restenosis

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Hideaki [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Mahmoudi, Michael [University of Surrey, Guildford Road, Surrey, GU2-7XH (United Kingdom); Torguson, Rebecca; Satler, Lowell F.; Suddath, William O.; Pichard, Augusto D. [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Waksman, Ron, E-mail: ron.waksman@medstar.net [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States)

    2015-04-15

    Objective: The aim of this study was to compare the safety and efficacy of the everolimus-eluting stents (EES) with the paclitaxel-eluting stent (PES) and sirolimus-eluting stent (SES) for the treatment of bare-metal in-stent restenosis. Background: The optimal treatment for bare-metal in-stent restenosis remains controversial. Methods: The study cohort comprised 322 consecutive patients (543 lesions) who presented with bare-metal in-stent restenosis to our institution and underwent coronary artery stent implantation with EES (114 patients; 181 lesions), PES (65 patients; 116 lesions) and SES (143 patients; 246 lesions). The analyzed clinical parameters were the 1-year rates of death, Q-wave myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), definite stent thrombosis (ST) and major adverse cardiac events (MACE) defined as the composite of death, MI, or TLR at 1-year. Results: The three groups were well matched for the conventional risk factors except for age and chronic kidney disease. The 1-year analyzed clinical parameters were similar in the three groups: death (EES = 3.5%, PES = 4.6%, SES = 4.2%; p = 0.94), MI (EES = 3.5%, PES = 6.3%, SES = 2.1%; p = 0.31), TLR (EES = 9.8%, PES = 9.5%, SES = 5.7%; p = 0.42), TVR (EES = 14.3%, PES = 11.1%, SES = 11.3%; p = 0.74), definite ST (EES = 0.9%, PES = 3.1%, SES = 3.5%; p = 0.38) and MACE (EES = 14.0%, PES = 15.4%, SES = 10.5%; p = 0.54). Male gender (hazard ratio = 0.47; 95% confidence interval = 0.25–0.88) and number of treated lesions (hazard ratio = 1.47; 95% confidence interval = 1.06–2.05) were found to be independent predictors of MACE. Conclusion: The results of the present study indicate that EES may provide similar safety and efficacy as first generation DES for the treatment of patients presenting with bare-metal in-stent restenosis.

  19. Evaluation of metal allergies in patients with coronary stents.

    Science.gov (United States)

    Hillen, U; Haude, M; Erbel, R; Goos, M

    2002-12-01

    In-stent restenosis is a complication which impairs the success of coronary stenting. Recently, it was supposed that a delayed hypersensitivity reaction to nickel and molybdenum might be one of the triggering factors in in-stent restenosis. We have analyzed the data collected in our centre with respect to this hypothesis. Altogether, 34 patients were investigated (24 male, 10 female). Patch tests were performed with the standard series of the German Contact Dermatitis Research Group and a metal series containing the metal components of 316 L stainless steel. A positive patch test reaction to nickel was observed in 4 (11.8%) patients. None of the patients showed sensitization to the other metals. Retrospective analysis was performed in 20 patients: 2 of these patients had a positive patch test reaction to nickel, one of whom had an in-stent restenosis, and the other not. Restenoses were predominantly observed in patients with negative patch test reactions to nickel (6/18 patients). Out of the patients who were investigated prospectively only one showed sensitization to nickel. Restenosis was observed in 2 patients: neither patient had nickel allergy. Although it still cannot be excluded that metal allergy may play a role in the restenosis process in coronary stenting, there is at present little evidence for it.

  20. Transaortic gunshot wound through perivisceral segment successfully managed by placement of thoracic stent graft

    Directory of Open Access Journals (Sweden)

    Jared T. Feyko, DO

    2018-03-01

    Full Text Available We describe a 36-year-old woman who presented to our facility after sustaining a gunshot wound to the epigastric region. The gunshot resulted in injury to the left lobe of the liver and the twelfth thoracic vertebral body as well as in a through-and-through injury to the abdominal aorta at the level of the celiac axis. The vascular injury was managed successfully by placement of a thoracic stent graft with coverage of the celiac axis. This case demonstrates the feasibility of managing this uncommon injury with endovascular techniques.

  1. Endovascular Treatment of Blunt Traumatic Abdominal Aortic Occlusion With Kissing Stent Placement

    International Nuclear Information System (INIS)

    Idoguchi, Koji; Yamaguchi, Masato; Okada, Takuya; Nomura, Yoshikatsu; Sugimura, Kazuro; Okita, Yutaka; Sugimoto, Koji

    2012-01-01

    Blunt traumatic abdominal aortic dissection is extremely rare and potentially deadly. We present the case of a 62-year-old man involved in a frontal car crash. After emergency undergoing laparotomy for bowel injuries, he was referred to our hospital due to acute ischemia of bilateral lower extremities on day 3 after the trauma. Computed tomography and aortography showed an aortobiiliac dissection with complete occlusion. This injury was successfully treated by endovascular treatment with “kissing”-technique stent placement, which appears to be a safe, effective, and minimally invasive treatment.

  2. Endovascular Treatment of Blunt Traumatic Abdominal Aortic Occlusion With Kissing Stent Placement

    Energy Technology Data Exchange (ETDEWEB)

    Idoguchi, Koji, E-mail: idoguchi@ares.eonet.ne.jp; Yamaguchi, Masato; Okada, Takuya [Kobe University Hospital, Department of Radiology and Center for Endovascular Therapy (Japan); Nomura, Yoshikatsu [Kobe University Hospital, Department of Cardiovascular Surgery (Japan); Sugimura, Kazuro [Kobe University Hospital, Department of Radiology and Center for Endovascular Therapy (Japan); Okita, Yutaka [Kobe University Hospital, Department of Cardiovascular Surgery (Japan); Sugimoto, Koji [Kobe University Hospital, Department of Radiology and Center for Endovascular Therapy (Japan)

    2012-10-15

    Blunt traumatic abdominal aortic dissection is extremely rare and potentially deadly. We present the case of a 62-year-old man involved in a frontal car crash. After emergency undergoing laparotomy for bowel injuries, he was referred to our hospital due to acute ischemia of bilateral lower extremities on day 3 after the trauma. Computed tomography and aortography showed an aortobiiliac dissection with complete occlusion. This injury was successfully treated by endovascular treatment with 'kissing'-technique stent placement, which appears to be a safe, effective, and minimally invasive treatment.

  3. The role of MR angiography before transjugular placement of a portosystemic stent shunt (TIPS)

    International Nuclear Information System (INIS)

    Mueller, M.F.; Siewert, B.; Kim, D.; Edelman, R.R.; Stokes, K.R.; Finn, J.P.

    1994-01-01

    The authors employed magnetic resonance angiography (MRA) to guide catheter placement for transjugular intrahepatic portosystemic stent shunt (TIPS) procedures in 14 of 24 patients, and compared the results to the 10 patients who did not have prior panning based on MRA. Two-dimensional time-of-flight venography was performed during breath holding, and projection venograms were formatted in sagittal, coronal and axial planes. MRA defined venous anatomy sufficiently well to shorten the procedure and helped to minimize invasiveness. With MRA guidance, intrahepatic needle punctures were significantly fewer (without MRA guidance: mean 12.1; with MRA guidance: mean 3.5, p [de

  4. Removal of metallic tracheobronchial stents in lung transplantation with flexible bronchoscopy

    Directory of Open Access Journals (Sweden)

    Fruchter Oren

    2010-09-01

    Full Text Available Abstract Background Airway complications are among the most challenging problems after lung transplantation, and Self-Expandable Metallic Stents (SEMS are used to treat airway complications such as stenosis or malacia at the bronchial anastomosis sites. Several transplantation centers are reluctant to use SEMS since their removal is sometimes needed and usually requires the use of rigid bronchoscopy under general anesthesia. The objective of the current report is to describe our experience in SEMS retrieval by flexible bronchoscopy under conscious sedation. Methods A retrospective review was done of patients requiring tracheobronchial stent placement after lung transplantation in which the SEMS had to be removed. The retrieval procedure was done by flexible bronchoscopy on a day-care ambulatory basis. Results Between January 2004 and January 2010, out of 305 lung transplantation patients, 24 (7.8% underwent SEMS placement. Indications included bronchial stenosis in 20 and bronchomalacia in 4. In six patients (25% the SEMS had to be removed due to excessive granulation tissue formation and stent obstruction. The average time from SEMS placement to retrieval was 30 months (range 16-48 months. The stent was completely removed in five patients and partially removed in one patient; no major complications were encountered, and all patients were discharged within 3 hours of the procedure. In all procedures, new SEMS was successfully re-inserted thereafter. Conclusions The retrieval of SEMS in patients that underwent lung transplantation can be effectively and safely done under conscious sedation using flexible bronchoscopy on a day-care basis, this observation should encourage increasing usage of SEMS in highly selected patients.

  5. Long term results of endovascular treatment in renal arterial stenosis from Takayasu arteritis: Angioplasty versus stent placement

    International Nuclear Information System (INIS)

    Park, Hong Suk; Do, Young Soo; Park, Kwang Bo; Kim, Duk-Kyung; Choo, Sung Wook; Shin, Sung Wook; Cho, Sung Ki; Hyun, Dongho; Choo, In Wook

    2013-01-01

    Purpose: To retrospectively evaluate and compare the long term patency and antihypertensive effect of angioplasty and stent insertion in renal artery stenosis caused by Takayasu arteritis, with CT angiography and clinical follow-up. Materials and methods: We retrospectively analyzed and compared effects on hypertension and patency of renal artery in 16 patients (age ranging from 16 to 58 years, mean: 32.1 years) with renovascular hypertension caused by Takayasu arteritis who underwent endovascular treatment including angioplasty (n = 13) and stent placement (n = 9) for 22 stenotic renal arteries. Results: Technical success was 95% (21/22) without major complications. In the last follow-up CT angiogram (mean 85 ± 41 months), restenosis was 8% (1/12) in angioplasty and 66% (6/9) in stent. Patency rates of angioplasty were 100%, 91.7%, 91.7% and primary unassisted and primary assisted patency rates of stent placement were 55.6%, 33.3%, 33.3% and 88.9%, 66.7%, 55.6% at 1-, 3- and 5-years, respectively. In clinical follow-up (mean 120 ± 37.8 months, range 48–183 months), beneficial effects on hypertension were obtained in 87% of patients (13/15) and there was no significant difference between the patients who were treated by only angioplasty and the patients who received stent placement in at least one renal artery, regardless of whether or not angioplasty had been performed in the other renal artery. Conclusion: Compared with stent placement, angioplasty demonstrated better long term patency and similar clinical benefit on renovascular hypertension in renal artery stenosis of Takayasu arteritis. We suggest that stent placement should be reserved for obvious angioplasty failure

  6. The effectiveness of ureteric metal stents in malignant ureteric obstructions: A systematic review

    Directory of Open Access Journals (Sweden)

    Panagiotis Kallidonis

    2017-12-01

    Full Text Available Objective: To review the literature on the effectiveness, safety and long-term patency of ureteric metal mesh stents (MSs, as a variety of MSs have been used for managing malignant ureteric obstruction over the last three decades. Materials and methods: A systematic review using the search string; Ureter∗ AND (stent OR endoprosthesis AND metal∗ was conducted on PubMed, Scopus, Web of science and Cochrane Library online databases in May 2016. Prospective, retrospective, and comparative studies including MSs were included. The primary endpoint was the patency rate and the secondary endpoint was complications. Results: In all, 324 publications were screened and 31 articles were included in the systematic review; 21 prospective and 10 retrospective studies. These studies reported the effectiveness of specific MSs in population studies, in comparative studies among different MSs, as well as among MSs and JJ stents. It should be noted that all comparative studies were retrospective. Conclusion: The experiences with vascular MSs, such as the Wallstent™ (Boston Scientific/Microvasive, Natick, MA, USA, were related to high occlusion rates, due to endoluminal hyperplasia, and long-term disappointing patency. The use of covered MSs designed for the vascular system was also unfavourable. The Memokath 051™ (PNN Medical A/S, Kvistgaard, Denmark had better patency rates, but also higher migration rates. The long-term results were acceptable and rendered the Memokath 051 as a viable option for the management of malignant ureteric obstruction. The Uventa™ (Taewoong Medical, Seoul, Korea and Allium™ (Allium Medical Solutions Ltd, Caesarea, Israel MSs, specifically designed for ureteric placement, provided promising results. Nevertheless, the wide acceptance of these MSs would require well-designed clinical studies and long-term follow-up. Keywords: Stent, Metal stent, Ureteric obstruction, Malignant

  7. Percutaneous ureteral stent placement for the treatment of a benign ureteral obstruction in a Sumatran tiger (Panthera tigris sumatrae).

    Science.gov (United States)

    Delk, Katie W; Wack, Raymund F; Burgdorf-Moisuk, Anne; Palm, Carrie A; Zwingenberger, Allison; Glaiberman, Craig B; Ferguson, Kenneth H; Culp, William T N

    2015-01-01

    A 15-year-old, 113 kg intact male Sumatran tiger (Panthera tigris sumatrae) was evaluated for weight loss, polydipsia, and intermittent hematuria. The tiger was immobilized for diagnostic testing including blood work, urinalysis, and abdominal ultrasound. Laboratory testing demonstrated macro- and microhematuria, azotemia, and an increased urine protein:creatinine ratio. Abdominal ultrasound revealed bilateral ureterolithiasis as well as hydronephrosis and ureteral dilation. Ultrasonography performed 5 months later revealed worsening of the right-sided hydronephrosis and hydroureter and a decrease in the severity of dilation on the left side presumably from passage of the left-sided ureteral calculi. Nephroureteral decompression via the placement of a stent was elected. A pigtail ureteral catheter (8.2 French diameter) was placed in the right ureter via an antegrade percutaneous approach utilizing ultrasound and fluoroscopic-guidance. Following stent placement, macrohematuria resolved although microhematuria was noted in opportunistic urine samples. Five months after stent placement, the azotemia had mildly progressed, the urine protein:creatinine ratio was improved, the right hydronephrosis and hydroureter had completely resolved, and the ureteral stent remained in the appropriate position. The tiger had clinically improved with a substantial increase in appetite, weight, and activity level. Ureteral stenting allowed for nephroureteral decompression in the captive large felid of this report, and no complications were encountered. Ureteral stenting provided a minimally invasive method of managing ureteral obstruction in this patient and could be considered in future cases due to the clinical improvement and low morbidity. © 2015 Wiley Periodicals, Inc.

  8. Risks and Benefits of Postoperative Double-J Stent Placement After Ureteroscopy: Results from the Clinical Research Office of Endourological Society Ureteroscopy Global Study

    NARCIS (Netherlands)

    Muslumanoglu, Ahmet Y.; Fuglsig, Sven; Frattini, Antonio; Labate, Gaston; Nadler, Robert B.; Martov, Alexey; Wong, Carson; de La Rosette, Jean J. M. C. H.

    2017-01-01

    Double-J stent placement after stone removal by ureteroscopy (URS) is common and recommended in many cases but debatable in others. In this study, the risks and benefits of postoperative Double-J stent placement in URS stone treatment procedures undertaken in current clinical practice are examined.

  9. Bilateral Renal Fornix Rupture Following Intraarterial Contrast Medium Application for Infrarenal Aortic Stent Placement

    International Nuclear Information System (INIS)

    Niggemann, Pascal; Brehmer, Bernhard; Schuermann, Karl

    2006-01-01

    A 74-year-old male claudicant who had a significant abdominal aortic stenosis was hydrated before aortic stent placement because of an elevated creatinine level. During the intervention the patient experienced acute abdominal pain with vomiting. No vascular cause was detected. Due to persistant pain, plain radiography and an abdominal CT scan were performed a few hours after the procedure. Images revealed a bilateral renal fornix rupture with a large retroperitoneal fluid collection. The patient was treated conservatively with ureteral double-J placement and percutaneous nephrostomy. The further course was uneventful and the patient was discharged 2 weeks later free of symptoms. Renal fornix rupture is a very rare complication after contrast medium application that can be treated without surgery

  10. Self-expandable metal stents for obstructing colonic and extracolonic cancer

    DEFF Research Database (Denmark)

    van Hooft, Jeanin E; van Halsema, Emo E; Vanbiervliet, Geoffroy

    2014-01-01

    This Guideline is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE). This Guideline was also reviewed and endorsed by the Governing Board of the American Society for Gastrointestinal Endoscopy (ASGE). The Grading of Recommendations Assessment, Development, and Eva......This Guideline is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE). This Guideline was also reviewed and endorsed by the Governing Board of the American Society for Gastrointestinal Endoscopy (ASGE). The Grading of Recommendations Assessment, Development......, and Evaluation (GRADE) system was adopted to define the strength of recommendations and the quality of evidence. Main recommendations The following recommendations should only be applied after a thorough diagnostic evaluation including a contrast-enhanced computed tomography (CT) scan. 1 Prophylactic colonic...... stent placement is not recommended. Colonic stenting should be reserved for patients with clinical symptoms and imaging evidence of malignant large-bowel obstruction, without signs of perforation (strong recommendation, low quality evidence). 2 Colonic self-expandable metal stent (SEMS) placement...

  11. Biliary Leak in Post-Liver-Transplant Patients: Is There Any Place for Metal Stent?

    Directory of Open Access Journals (Sweden)

    Fernanda P. Martins

    2012-01-01

    Full Text Available Objectives. Endoscopic management of bile leak after orthotopic liver transplant (OLT is widely accepted. Preliminary studies demonstrated encouraging results for covered self-expandable metal stents (CSEMS in complex bile leaks. Methods. Thirty-one patients with post-OLT bile leaks underwent endoscopic temporary placement of CSEMS (3 partially CSEMS , 18 fully CSEMS with fins and 10 fully CSEMS with flare ends between December 2003 and December 2010. Long-term clinical success and safety were evaluated. Results. Median stent indwelling and follow-up were 89 and 1,353 days for PCSEMS, 102 and 849 for FCSEMS with fins and 98 and 203 for FCSEMS with flare ends. Clinical success was achieved in 100%, 77.8%, and 70%, respectively. Postplacement complications: cholangitis (1 and proximal migration (1, both in the FCSEMS with fins. Postremoval complications were biliary strictures requiring drainage: PCSEMS (1, FCSEMS with fins (6 and with flare ends (1. There was no significant differences in the FCSEMS groups regarding clinical success, age, gender, leak location, previous treatment, stent indwelling, and complications. Conclusion. Temporary placement of CSEMS is effective to treat post-OLT biliary leaks. However, a high number of post removal biliary strictures occurred especially in the FCSEMS with fins. CSEMS cannot be recommended in this patient population.

  12. Expandable Metal Stents for the Palliation of Malignant Gastroduodenal Obstruction

    International Nuclear Information System (INIS)

    Razzaq, Rubeena; Laasch, Hans-Ulrich; England, Ruth; Marriott, Angie; Martin, Derrick

    2001-01-01

    Purpose: Gastric outlet obstruction is a debilitating complication of upper gastrointestinal malignancy. We present our experience with insertion of self-expanding metal stents (SEMS).Methods: Twenty-eight patients were referred, stenting being attempted in 23. Two patients had esophageal Wallstents inserted through a gastrostomy; 21 had an endoscopic approach with enteral Wallstents.Results: One stent insertion failed, ten patients (45%) returned to a normal diet, ten patients (45%) managed semi-solid food and two patients (9%) had no significant improvement. No immediate complications were seen. One patient subsequently developed pancreatitis. Reintervention (4 stents, 1 jejunostomy, 1 gastro jejunostomy) was required in six of 22 patients (27%) for inadequate stent expansion (1), second stricture (2), stent migration (1), and tumor ingrowth (2). The mean survival was 95.4 days (SD 78.8 days, range 3-230 days). The mean follow-up time was 98.9 days (SD 86.7 days, range 3-309 days).Conclusions: SEMS are effective in palliating malignant gastric outlet obstruction. A combined endoscopic/fluoroscopic approach allows the most complete assessment of the stricture and removes the need for gastrostomy insertion. Careful assessment of the gastrointestinal tract distal to the lesion is important

  13. Effects of cobalt-chromium everolimus eluting stents or bare metal stent on fatal and non-fatal cardiovascular events

    DEFF Research Database (Denmark)

    Valgimigli, Marco; Sabaté, Manel; Kaiser, Christoph

    2014-01-01

    eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. PRIMARY OUTCOMES: The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite...... a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; P... coronary syndrome v stable coronary artery disease), diabetes mellitus, female sex, use of glycoprotein IIb/IIIa inhibitors, and up to one year v longer duration treatment with dual antiplatelets. CONCLUSIONS: This meta-analysis offers evidence that compared with bare metal stents the use of cobalt...

  14. Use of the covered Y-shaped metallic stent in the treatment of airway stenoses involving the lower trachea and the tracheal carina: preliminary clinical study

    International Nuclear Information System (INIS)

    Yang Ruimin; Li Fenbao; Zhang Mingqiu; Wu Gang; Han Xinwei

    2007-01-01

    Objective: To describe a new kind of Y-shaped metallic stent delivery system and evaluate its feasibility and preliminary effect for managing multiple airway stenoses involving the lower trachea and the tracheal carina. Methods: The Y-shaped metallic stent delivery system consisted of three-tier structure. The inner-tier was composed of four parallel guiding tubes, which was used for two guidewires and two threads passing through, the middle-tier was delivery catheter, which contained the four guiding tubes, and the outer-tier was introducer sheath. Under the fluoroscopic guidance, 15 patients with multiple stenoses involving the lower trachea and the tracheal carina were treated with the new covered self-expandable Y-shaped metallic stents. Results: Stent placement in the tracheo-bronchial tree was technically successful in all patients with obliteration of the dyspnea immediately after stent placement, and SaO2 was increased form preoperative 75%-89% to postoperative 96%-99%. During follow-up a period of 3-58 weeks (M 22 weeks), all stenosis were resolved without stent-related complications, and the general physical of all 15 patents was improved with no occurrence of obviously dyspnea and bleeding. Karnofsky performance status (KPS) was improved from preoperative 26%-45% to postoperative 72%-95%. Five patients died of the following causes unrelated to stent insertion: multiple organ failure (n=3), cachexia (n=1) and pulmonary infection caused by gastrobronehial fistula (n=1), and the remaining 10 patients were alive with no evidence of dyspnea at the time of this report. Conclusion: Deployment of the covered Y-shaped metallic stent with the use of Y metallic stent delivery system in the management of airway stenoses involving the lower trachea and the tracheal carina was a simple and safe procedure and with a good short-term clinical efficacy. (authors)

  15. Future developments in biliary stenting

    Directory of Open Access Journals (Sweden)

    Hair CD

    2013-06-01

    Full Text Available Clark D Hair,1 Divyesh V Sejpal21Department of Medicine, Section of Gastroenterology and Hepatology, Baylor College of Medicine, Houston, TX, USA; 2Department of Medicine, Section of Gastroenterology, Hofstra North Shore-LIJ School of Medicine, North Shore University Hospital, Manhasset, NY, USAAbstract: Biliary stenting has evolved dramatically over the past 30 years. Advancements in stent design have led to prolonged patency and improved efficacy. However, biliary stenting is still affected by occlusion, migration, anatomical difficulties, and the need for repeat procedures. Multiple novel plastic biliary stent designs have recently been introduced with the primary goals of reduced migration and improved ease of placement. Self-expandable bioabsorbable stents are currently being investigated in animal models. Although not US Food and Drug Administration approved for benign disease, fully covered self-expandable metal stents are increasingly being used in a variety of benign biliary conditions. In malignant disease, developments are being made to improve ease of placement and stent patency for both hilar and distal biliary strictures. The purpose of this review is to describe recent developments and future directions of biliary stenting.Keywords: plastic stents, self-expandable metal stents, drug eluting stents, bioabsorbable stents, malignant biliary strictures, benign biliary strictures

  16. Self-expandable metal stents for relieving malignant colorectal obstruction: short-term safety and efficacy within 30 days of stent procedure in 447 patients

    DEFF Research Database (Denmark)

    Meisner, Søren; González-Huix, Ferran; Vandervoort, Jo G

    2011-01-01

    The self-expandable metal stent (SEMS) can alleviate malignant colonic obstruction and avoid emergency decompressive surgery.......The self-expandable metal stent (SEMS) can alleviate malignant colonic obstruction and avoid emergency decompressive surgery....

  17. A Multicenter, Prospective Study of a New Fully Covered Expandable Metal Biliary Stent for the Palliative Treatment of Malignant Bile Duct Obstruction

    Directory of Open Access Journals (Sweden)

    Bret T. Petersen

    2013-01-01

    Full Text Available Background and Study Aims. Endoscopic placement of self-expanding metal stents (SEMSs is indicated for palliation of inoperable malignant biliary obstruction. A fully covered biliary SEMS (WallFlex Biliary RX Boston Scientific, Natick, USA was assessed for palliation of extrahepatic malignant biliary obstruction. Patients and Methods. 58 patients were included in this prospective, multicenter series conducted under an FDA-approved IDE. Main outcome measurements included (1 absence of stent occlusion within six months or until death, whichever occurred first and (2 technical success, need for reintervention, bilirubin levels, stent patency, time to stent occlusion, and adverse events. Results. Technical success was achieved in 98% (57/58, with demonstrated acute removability in two patients. Adequate clinical palliation until completion of followup was achievedin 98% (54/55 of evaluable patients, with 1 reintervention due to stent obstruction after 142 days. Mean total bilirubin decreased from 8.9 mg/dL to 1.2 mg/dL at 1 month. Device-related adverse events were limited and included 2 cases of cholecystitis. One stent migrated following radiation therapy. Conclusions. The WallFlex Biliary fully covered stent yielded technically successful placement with uncomplicated acute removal where required, appropriate reduction in bilirubin levels, and low rates of stent migration and occlusion. This SEMS allows successful palliation of malignant extrahepatic biliary obstruction.

  18. Polymeric photosensitizer-embedded self-expanding metal stent for repeatable endoscopic photodynamic therapy of cholangiocarcinoma.

    Science.gov (United States)

    Bae, Byoung-chan; Yang, Su-Geun; Jeong, Seok; Lee, Don Haeng; Na, Kun; Kim, Joon Mee; Costamagna, Guido; Kozarek, Richard A; Isayama, Hiroyuki; Deviere, Jacques; Seo, Dong Wan; Nageshwar Reddy, D

    2014-10-01

    Photodynamic therapy (PDT) is a new therapeutic approach for the palliative treatment of malignant bile duct obstruction. In this study, we designed photosensitizer-embedded self-expanding nonvascular metal stent (PDT-stent) which allows repeatable photodynamic treatment of cholangiocarcinoma without systemic injection of photosensitizer. Polymeric photosensitizer (pullulan acetate-conjugated pheophorbide A; PPA) was incorporated in self-expanding nonvascular metal stent. Residence of PPA in the stent was estimated in buffer solution and subcutaneous implantation on mouse. Photodynamic activity of PDT-stent was evaluated through laserexposure on stent-layered tumor cell lines, HCT-116 tumor-xenograft mouse models and endoscopic intervention of PDT-stent on bile duct of mini pigs. Photo-fluorescence imaging of the PDT-stent demonstrated homogeneous embedding of polymeric Pheo-A (PPA) on stent membrane. PDT-stent sustained its photodynamic activities at least for 2 month. And which implies repeatable endoscopic PDT is possible after stent emplacement. The PDT-stent after light exposure successfully generated cytotoxic singlet oxygen in the surrounding tissues, inducing apoptotic degradation of tumor cells and regression of xenograft tumors on mouse models. Endoscopic biliary in-stent photodynamic treatments on minipigs also suggested the potential efficacy of PDT-stent on cholangiocarcinoma. In vivo and in vitro studies revealed our PDT-stent, allows repeatable endoscopic biliary PDT, has the potential for the combination therapy (stent plus PDT) of cholangiocarcinoma. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Percutaneous transhepatic self-expanding metal stents for palliation ...

    African Journals Online (AJOL)

    Department of Surgery, Faculty of Health Sciences, University of Cape Town, and Surgical Gastroenterology, Groote Schuur. Hospital, Cape Town. Background. Malignant biliary obstruction is often inoperable at presentation and has a poor prognosis. Percutaneously placed self- expanding metal stents (SEMS) have been ...

  20. Treatment of postoperative main portal vein and superior mesenteric vein thrombosis with balloon angioplasty and/or stent placement.

    Science.gov (United States)

    Cao, Guangshao; Ko, Gi-Young; Sung, Kyu-Bo; Yoon, Hyun-Ki; Gwon, Dong Il; Kim, Jin-Hyoung

    2013-06-01

    Thrombolysis and mechanical thrombectomy have been used to treat postoperative main portal vein and superior mesenteric vein thrombosis. To evaluate the safety and efficacy of balloon angioplasty and/or stent placement without thrombolysis or thrombectomy for treating such thromboses. Fourteen patients with postoperative main portal vein or superior mesenteric vein thrombosis underwent percutaneous transhepatic balloon angioplasty and/or stent placement without thrombolysis or thrombectomy. The rates of technical and clinical success, major complications, and recurrence were evaluated retrospectively. Initial technical success was achieved in 13 of the 14 patients (93%). After the procedures, these 13 patients showed brisk portal inflow, without a significant amount of residual thrombus in the stented lumen or embolism. One patient was considered to be a technical failure despite showing a brisk portal inflow because 50% stenosis and partial residual thrombus remained in the stented lumen. Initial clinical success was achieved in 13 patients. One patient with technical success died of acute respiratory distress syndrome 8 days after the procedure, whereas one patient with technical failure achieved clinical success. One patient experienced acute rethrombosis 8 days after the procedure. During the median follow-up period of 16.3 months, rethrombosis occurred in six patients (43%), including one patient with acute rethrombosis. Balloon angioplasty and/or stent placement without thrombolysis or thrombectomy may be a safe and effective treatment modality for postoperative main portal vein and superior mesenteric vein thrombosis. © 2013 The Foundation Acta Radiologica.

  1. Overcoming the delivery limitation: results of an approach to implanting an integrated self-expanding Y-shaped metallic stent in the carina.

    Science.gov (United States)

    Han, Xin-Wei; Wu, Gang; Li, Yong-Dong; Zhang, Qing-Xian; Guan, Sheng; Ma, Nan; Ma, Ji

    2008-05-01

    To evaluate the technical success and initial clinical safety and effectiveness of the use of a Y-shaped metallic stent for complex stenoses involving the carina. Thirty-five consecutive patients with complex tracheobronchial stenoses involving the carina were treated with an integrated self-expandable inverted Y-shaped metallic stent and delivery system. The Y-shaped metallic stents were placed in the tracheobronchial tree with fluoroscopic guidance. Technical success, clinical success, Hugh-Jones classification, and complications were assessed during follow-up. The delivery of the integrated self-expandable Y-shaped metallic stent in the carinal areas was technically successful and well-tolerated in all patients. Clinical success was achieved in 31 patients (89%) 1-7 days after stent placement; the procedure failed in four patients (11%). The improvement between pre- and postoperative Hugh-Jones classification grade was statistically significant (Preport. The mean and median survival periods were 217 days+/-30 and 215 days+/-108, respectively. The mean and median stent patency periods were 216 days+/-30 and 215 days+/-119, respectively. Deployment of an integrated, self-expandable inverted Y-shaped metallic stent with the delivery system was a safe and effective procedure for the treatment of complex tracheobronchial stenoses involving the carina.

  2. Stent selection in patients with myocardial infarction: drug eluting, biodegradable polymers or bare metal stents?

    Science.gov (United States)

    Mieres, Juan; Rodríguez, Alfredo E

    2012-08-01

    Percutaneous coronary intervention (PCI) has been increasingly used in the last years during interventional procedures in patients with acute coronary syndromes (ACS) including ST elevation myocardial infarction (STEMI) and non-ST elevation myocardial infarction (NSTEMI). In patients with either STEMI, NSTEMI, high risk ACS with EKG changes or cardiac enzymes rises; PCI with bare metal stent (BMS) implantation has been associated with a significant improvement in clinical outcome. Therefore, BMS implantation during primary PCI in STEMI has become a standard of practice. With the introduction of drug eluting stents (DESs) in this decade, the use of these new devices instead of BMSs in patients with STEMI has emerged as a rational PCI alternative in this particular subgroup of patients. In spite of the unquestionable benefits of DESs in terms of reduction of restenosis and TVR, specific concerns have arisen with regard to their long-term safety. High incidence of very late stent thrombosis has been described with these devices, and special attention should be paid in patients with unstable coronary lesions, in which plaque composition and remodeling may play a main role in their safety and long-term outcome. Intraluminal thrombus caused by plaque rupture is the most frequent mechanism of STEMI, in which the necrotic core and thin fibrous cap play a major role. In this context, the use of first DESs designs may be futile or even unsafe because delayed healing may further contribute to plaque instability. Adjunctive invasive imaging tools can improve stent deployment and safety outcome in these lesions with intravascular findings of plaque instability. Recently, other players such as new dedicated antithrombotic BMS designs, including selfexpanding stents or drug-eluting coated balloons, are exploring their potential indications in patients with ACS and myocardial infarction. This paper reports and discusses new stent devices and adjunctive pharmacologic agents. It

  3. Contrast Medium Induced Nephropathy after Endovascular Stent Graft Placement: An Examination of Its Prevalence and Risk Factors

    International Nuclear Information System (INIS)

    Kawatani, Yohei; Nakamura, Yoshitsugu; Mochida, Yoshihiko; Yamauchi, Naoya; Hayashi, Yujiro; Taneichi, Tetsuyoshi; Ito, Yujiro; Kurobe, Hirotsugu; Suda, Yuji; Hori, Takaki

    2016-01-01

    Endovascular stent graft placement has become a major treatment for thoracic and abdominal aneurysms. While endovascular therapy is less invasive than open surgery, it involves the use of a contrast medium. Contrast media can cause renal impairment, a condition termed as contrast-induced nephropathy (CIN). This study sought to evaluate the incidence and risk factors of CIN following endovascular stent graft placement for aortic aneurysm repair. The study included 167 consecutive patients who underwent endovascular stent graft placement in our hospital from October 2013 to June 2014. CIN was diagnosed using the European Society of Urogenital Radiology criteria. Patients with and without CIN were compared. Chi-squared tests, t-tests, and multivariate logistic regression analyses were performed. Thirteen patients (7.8%) developed CIN. Left ventricular dysfunction and intraoperative blood transfusion were significantly more frequent in the CIN group (P = 0.017 and P = 0.032, resp.). Multivariate analysis showed that left ventricular dysfunction had the strongest influence on CIN development (odds ratio 9.34, P = 0.018, and 95% CI = 1.46–59.7). Patients with CIN also experienced longer ICU and hospital stays. Measures to improve renal perfusion flow should be considered for patients with left ventricular dysfunction who are undergoing endovascular stent graft placement

  4. Percutaneous subclavian artery stent-graft placement following failed ultrasound guided subclavian venous access

    Directory of Open Access Journals (Sweden)

    Szkup Peter

    2006-05-01

    Full Text Available Abstract Background Ultrasound guidance for central and peripheral venous access has been proven to improve success rates and reduce complications of venous cannulation. Appropriately trained and experienced operators add significantly to diminished patient morbidity related to venous access procedures. We discuss a patient who required an arterial stent-graft to prevent arterial hemorrhage following inadvertent cannulation of the proximal, ventral, right subclavian artery related to unsuccessful ultrasound guided access of the subclavian vein. Case presentation During pre-operative preparation for aortic valve replacement and aorto-coronary bypass surgery an anesthetist attempted ultrasound guided venous access. The ultrasound guided attempt to access the right jugular vein failed and the ultrasound guided attempt at accessing the subclavian vein resulted in inappropriate placement of an 8.5 F sheath in the arterial system. Following angiographic imaging and specialist consultations, an arterial stent-graft was deployed in the right subclavian artery rather than perform an extensive anterior chest wall resection and dissection to extract the arterial sheath. The patient tolerated the procedure, without complication, despite occlusion of the right internal mammary artery and the right vertebral artery. There were no neurologic sequelae. There was no evidence of hemorrhage after subclavian artery sheath extraction and stent-graft implantation. Conclusion The attempted ultrasound guided puncture of the subclavian vein resulted in placement of an 8.5 F subclavian artery catheter. Entry of the catheter into the proximal subclavian artery beneath the medial clavicle, the medial first rib and the manubrium suggests that the operator, most likely, did not directly visualize the puncture needle enter the vessel with the ultrasound. The bones of the anterior chest impede the ultrasound beam and the vessels in this area would not be visible to ultrasound

  5. Office stent placement under local anesthesia is a safe and efficient procedure for the management of multiple ureteral disorders.

    Science.gov (United States)

    Carrion, A; D'Anna, M; Costa-Grau, M; Luque, P; García-Cruz, E; Franco, A; Alcaraz, A

    2018-03-01

    To assess the outcomes of ureteral stent placement under local anesthesia for the management of multiple ureteral disorders. Retrospective study of 45 consecutive ureteral stents placed under local anesthesia from January 2015 to July 2016. Inclusion criteria were hemodynamically stable patients with urinary obstruction, urinary fistula or for prophylactic ureteral localization during surgery. Five minutes before the procedure, 10ml of lidocaine gel and 50ml of lidocaine solution were instilled in the bladder. A 4.8Fr ureteral stent was placed using a 15.5Fr flexible cystoscope under fluoroscopic control. Characteristics of procedures and outcomes were analysed. A total of 45 procedures (33 placement, 12 replacements) were attempted in 37 patients, of which 40 (89%) were successful. There were 10 male (27%) and 27 female patients (73%) with a mean age of 58.6 years (±17.5). Main indications for stent placement were stones (37.8%), extrinsic ureteral compression (28.9%) and surgery ureteral localization (22.2%). The reasons for failing to complete a procedure were the inability to pass the guidewire/stent in 4 cases (8.8%) or to identify the ureteral orifice in 1 (2.2%). Postoperative complications occurred in 8 patients (17.8%) (7 Clavien I, 1 Clavien IIIa). No procedure was prematurely terminated due to pain. Statistical analysis did not find significant successful predictors. The outpatient setting provided a fourfold cost decrease. Ureteral stent placement can be safely and effectively performed under local anesthesia in the office cystoscopy room. This procedure could free operating room time, reduce costs and minimize side effects of general anesthesia. Copyright © 2017 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. Comparison of Acute Recoil between Bioabsorbable Poly-L-lactic Acid XINSORB Stent and Metallic Stent in Porcine Model

    Directory of Open Access Journals (Sweden)

    Yizhe Wu

    2012-01-01

    Full Text Available Objective. To investigate acute recoil of bioabsorbable poly-L-lactic acid (PLLA stent. Background. As newly developed coronary stent, bioabsorbable PLLA stent still encountered concern of acute stent recoil. Methods. Sixteen minipigs were enrolled in our study. Eight PLLA XINSORB stents (Weite Biotechnology Co., Ltd., China and eight metallic stents (EXCEL, Jiwei Co., Ltd. China were implanted into coronary arteries. Upon quantitative coronary angiography analysis, acute absolute recoil was defined as the difference between mean diameter of inflated balloon (X and mean lumen diameter of stent immediately after deployment (Y, while acute percent recoil was defined as (X−Y/X and expressed as a percentage. Intravascular ultrasound (IVUS was performed immediately after implantation and 24 hours later to compare cross-sectional area (CSA between two groups and detect stent malapposition or collapse. Results. Acute absolute recoil in XINSORB and EXCEL was 0.02±0.13 mm and −0.08±0.08 mm respectively (P=0.19. Acute percent recoil in XINSORB and EXCEL was 0.66±4.32% and −1.40±3.83%, respectively (P=0.45. CSA of XINSORB was similar to that of EXCEL immediately after implantation, so was CSA of XINSORB at 24-hours followup. Within XINSORB group, no difference existed between CSA after implantation and CSA at 24-hours followup. No sign of acute stent malapposition was detected by IVUS. Conclusions. The acute stent recoil of XINSORB is similar to that of EXCEL. No acute stent malapposition or collapse appeared in both kinds of stent. This preclinical study was designed to provide preliminary data for future studies of long-term efficacy and safety of XINSORB stent.

  7. Novel flower-type covered metal stent to prevent cholecystitis: experimental study in a pig model.

    Science.gov (United States)

    Woo, Young Sik; Lee, Kwang Hyuck; Lee, Jong Kyun; Noh, Dong Hyo; Park, Joo Kyung; Lee, Kyu Taek; Jang, Kee-Taek

    2016-03-01

    Covered self-expandable metal stent (CSEMS) has the risk of obstruction of the cystic duct, and the main and branch pancreatic ducts due to strong radial force and covering material, which results in cholecystitis and pancreatitis. A flower-type covered self-expandable metal stent (F-CSEMS) having a five-petal-shaped design with side grooves was constructed to prevent the obstruction of the cystic duct orifice. This study investigated the value of the F-CSEMS in protection for cholecystitis in a pig model. Fourteen pigs randomly underwent endoscopic placement of either F-CSEMS or conventional CSEMS (C-CSEMS). The stent was placed across the cystic duct orifice to impede bile drainage from the gallbladder. Drainage was checked at 24, 48, 120 and 168 h after implantation. Blood was collected at baseline, on days 2 and 7 following implantation. The animals were killed for histologic evaluation on day 7. All stents were successfully inserted into bile duct without any procedure-related complications. At 48 h, the rate of contrast drainage from the gallbladder was higher in the F-CSEMS group than the C-CSEMS group without significant difference (71.4 vs. 28.6% p = 0.28). C-CSEMS was associated with higher levels of C-reactive protein (35.2 vs. 20.5 µg/dl, p = 0.03) and histologic inflammatory scores of gallbladder (score 4 vs. 2; p = 0.03). The F-CSEMS appears safe and helpful to prevent cholecystitis without disturbance of bile flow in a pig model.

  8. Drug-eluting stents vs bare metal stents for the treatment of large coronary vessels.

    Science.gov (United States)

    Quizhpe, Arturo R; Feres, Fausto; de Ribamar Costa, José; Abizaid, Alexandre; Maldonado, Galo; Costa, Ricardo; Abizaid, Andrea; Cano, Manuel; Moreira, Adriana C; Staico, Rodolfo; Mattos, Luiz Alberto; Tanajura, Luiz Fernando; Chaves, Aurea; Centemero, Marinella; Sousa, Amanda M R; Sousa, J Eduardo M R

    2007-08-01

    Lately drug-eluting stents (DES) have dramatically reduced restenosis rates and need for repeat revascularization in a wide subset of lesion and patients. However, their benefit for the treatment of large vessels (> 3.0 mm) has yet to be established. We investigated whether DES are superior to bare metal stents (BMS) in terms of clinical outcomes for the treatment of large coronary vessels. This study assessed the long-term outcomes (cardiac death, acute myocardial infarction, and need for repeat intervention in the treated vessel) of patients treated with either a DES (Cypher and Taxus) or a BMS of > or = 3.5 mm in diameter. A total of 250 consecutive patients who underwent DES implantation were clinically followed for 1 year and compared to 250 patients who were treated with BMS. Interventions in the setting of acute ST elevation myocardial infarction and treatment of bypass grafts were excluded. Cypher was the DES deployed in 70.8% of cases. Most of the enrolled patients were men (78%) with single vessel disease (65.6%). The left anterior descending artery was the culprit vessel in 34.2% of cases. Bare metal stent and DES cohorts had equivalent interpolated reference vessel diameter (3.19 +/- 0.3 mm for BMS vs 3.18 +/- 0.2 for DES; P = .1). Lesion was significantly longer in the group treated with DES (13.4 +/- 5.1 mm for BMS group vs 14.3 +/- 3.5 for DES; P = .0018). After 1 year of clinical follow-up, 95.2% of patients treated with DES and 91.2% of the patients who received BMS were free of major events (P = .2). A trend toward higher target-lesion revascularization was noticed in the group treated with BMS (4.8% vs 1.6%; P = .07). Percutaneous treatment of large coronary vessels carries a low risk of clinical events irrespective of the type of stent used.

  9. Stent

    Science.gov (United States)

    ... Drugs & Supplements Videos & Tools Español You Are Here: Home → Medical Encyclopedia → Stent URL of this page: //medlineplus.gov/ency/article/002303.htm Stent To use the sharing features on this page, please enable JavaScript. A stent is a tiny tube placed into a hollow structure in your ...

  10. Outcomes of second self-expandable metallic stent insertion for malignant gastric outlet obstruction.

    Science.gov (United States)

    Kim, Chan Gyoo; Choi, Il Ju; Lee, Jong Yeul; Cho, Soo-Jeong; Kim, Soo Jin; Kim, Mi-Jung; Park, Sook Ryun; Park, Young Lee

    2014-01-01

    Self-expandable metallic stents are used widely to relieve malignant gastric outlet obstruction (GOO). However, restenosis or migration of first stents is a frequent complication. The purpose of this retrospective cohort study was to evaluate the effectiveness of second stents as an approach to manage failure of first stents in patients with malignant GOO. A total of 222 patients with gastric cancer received first stents due to inoperable GOO at National Cancer Center in Korea between January 2008 and June 2011. Monthly follow-up interviews were performed, and second stents (stent-in-stent or stent-after-migration) were inserted in 59 patients by June 2012. Technical and clinical successes and long-term complications were evaluated. The technical and immediate clinical success rates were 98.3 % (58/59) and 91.5 % (54/59), respectively. Patients who received a second stent due to late complications involving the first stent (migration, restenosis, and fracture) showed a higher clinical success rate (95.8 % [46/48]) than patients who received a second stent due to immediate clinical failure of the first stent (72.7 % [8/11], p = 0.04). The immediate clinical success rate of stent-after-migration (100 % [11/11]) was not different from that of stent-in-stent (89.6 % [43/48], p = 1.0). The stent dysfunction rate of stent-after-migration (27.3 % [3/11]) also was similar to that of stent-in-stent (29.2 % [14/48], p = 1.0). The median patencies of stent-in-stent and stent-after-migration were 27.4 and 58.4 weeks, respectively (p = 0.177). There were no significant prognostic factors for patency of second stents. Insertion of a second stent is effective for treating the first-stent failure in gastric cancer patients with GOO, especially if the immediate outcome of the first stent was successful.

  11. Effect of biolimus-eluting stents with biodegradable polymer vs bare-metal stents on cardiovascular events among patients with acute myocardial infarction

    DEFF Research Database (Denmark)

    Räber, Lorenz; Kelbæk, Henning; Ostojic, Miodrag

    2012-01-01

    The efficacy and safety of drug-eluting stents compared with bare-metal stents remains controversial in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI)....

  12. Initial experience with Allium? stent in the management of bulbar urethral stricture

    OpenAIRE

    Silagy, Andrew; Merrett, Chris; Agarwal, Dinesh

    2017-01-01

    We herein present our initial experience of a short series with the Allium? Bulbar Urethral Stent (BUS) in the management of bulbar urethral disease. This Allium? stent is a self-expandable metal stent which is intended for temporary placement. Our series is a retrospective analysis of 15 BUS placements in 13 patients conducted during 2014 to 2016. BUS was placed successfully after visual internal urethrotomy (VIU) in all patients. Stent insertion was successful in 8 patients (62%) with a mea...

  13. Repeated transluminal endovascular Inoue stent graft placement for progressive dilatation of prosthetic graft that had been repaired with Inoue stent graft placement for dilatation 23 years after extraanatomical bypass.

    Science.gov (United States)

    Anzai, Tomohiro; Shimizu, Hideyuki; Yozu, Ryohei; Hashimoto, Subaru; Kuribayashi, Sachio; Inoue, Kanji

    2007-02-01

    A 76-year-old man had undergone aneurysm exclusion and ascending abdominal aortic extraanatomical bypass for a thoracoabdominal aortic aneurysm in 1978. In 1983 hemoptysis occurred, and resection and closure of the central stump of the aorta and a left lower lobectomy were performed. Dilatation (phi50 mm) of a prosthetic graft (Cooley Graft phi18 mm) used for extraanatomical bypass was noted in 2001 and was repaired by placement of an Inoue stent graft. However, the aneurysm diameter increased further (phi70 mm), although no endoleak was noted: Placement of an Inoue stent graft covering the whole length of the prosthetic graft was repeated in 2006. The postoperative course was smooth, no endoleak occurred, and the patient was discharged 2 weeks after surgery.

  14. Stent thrombosis, myocardial infarction, and death after drug-eluting and bare-metal stent coronary interventions

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Maeng, Michael; Kaltoft, Anne

    2007-01-01

    OBJECTIVES: The aim of the study was to examine outcomes subsequent to implantation of drug-eluting stents (DES) and bare-metal stents (BMS). BACKGROUND: Use of DES might be associated with increased risk of stent thrombosis (ST), myocardial infarction (MI), and death. METHODS: From January 2002...... the national databases. The Academic Research Consortium definition of ST was used. RESULTS: The DES were implanted in 3,548 patients (5,422 lesions) and BMS were implanted in 8,847 patients (11,730 lesions). Definite, probable, or possible ST was found in 190 (2.15%) patients in the BMS group and in 64 (1...

  15. Short-Term Biliary Stent Placement Contributing Common Bile Duct Stone Disappearance with Preservation of Duodenal Papilla Function

    Directory of Open Access Journals (Sweden)

    Tatsuki Ueda

    2016-01-01

    Full Text Available Aims. To investigate the effect of biliary stent placement without endoscopic sphincterotomy (EST on common bile duct stones (CBDS disappearance and the contribution of preserving the duodenal papilla function to reduce recurrence of CBDS. Methods. Sixty-six patients admitted for acute obstructive cholangitis due to CBDS who underwent biliary stent placement without EST for 2 years from March 2011 were evaluated retrospectively. The second endoscopic retrograde cholangiopancreatography (ERCP was performed for treatment of CBDS 3 to 4 months after the first ERCP. We estimated the rate of stone disappearance at the time of second ERCP. Results. CBDS disappearance was observed in 32 (48.5% of 66 patients. The diameter of the bile ducts and the diameter of CBDS in patients with CBDS disappearance were significantly smaller than in those with CBDS requiring extraction (p=0.007 and p<0.001, resp.. Stone disappearance was evident when the diameter of bile ducts and that of CBDS were <10 and 7 mm, respectively (p=0.002. Conclusions. Short-term stent placement without EST eliminates CBDS while preserving duodenal papilla function and may be suitable for treating CBDS in patients with nondilated bile ducts and small CBDS.

  16. Insertion of self-expanding metal stent for treatment of malignant obstruction in a pregnant woman

    Directory of Open Access Journals (Sweden)

    Noelia Alonso-Lázaro

    2014-03-01

    Full Text Available Colorectal cancer (CRC is the second most frequent cancer both in incidence and mortality in women, especially in those over 60 years of age. Diagnosis in women at gestational age is rare, so its incidence during pregnancy is low. However, an increase in its diagnosis is expected during the next years because of the raise in the average age of pregnancy. In most cases, the diagnosis is delayed because symptoms related to CRC can be attributed to pregnancy itself. Up to 30 % of CRC cases may present as an intestinal obstruction. In this situation, the main objective is to solve the clinical emergency in the safest way for mother and fetus, together with performing an accurate diagnostic approach to offer the best possible therapeutic management knowing the limitations and difficulties related to pregnancy. The self-expanding metallic stent (SEMS can be particularly useful in colon obstruction in a pregnant patient with CRC because it allows solving the acute condition providing time to perform a more accurate staging study and to prepare the patient for surgery, thus reducing both post-surgical morbidity and mortality. We report on the case of a patient who early in the second trimester of pregnancy presented with an acute colonic obstruction due to CRC which was successfully managed with the placement of a self-expanding metal stent.

  17. New 14-mm diameter Niti-S biliary uncovered metal stent for unresectable distal biliary malignant obstruction.

    Science.gov (United States)

    Kikuyama, Masataka; Shirane, Naofumi; Kawaguchi, Shinya; Terada, Shuzou; Mukai, Tsuyoshi; Sugimoto, Ken

    2018-01-16

    To investigate whether an uncovered self-expandable metal stent (UCSEMS) with a large diameter could prevent recurrent biliary obstruction (RBO). Thirty-eight patients with malignant biliary obstruction underwent treatment with an UCSEMS with a 14-mm diameter (Niti-S 14). Retrospectively, we evaluated technical and functional success rate, RBO rate, time to RBO, survival time, and adverse events in these patients. Stent placement success and functional success were achieved in all patients. Two patients (5.3%) had RBO due to tumor ingrowth or overgrowth. The median time to RBO was 190 (range, 164-215) d. The median survival time was 120 (range, 18-502) d. The 6-mo non-RBO rate was 91%. Other adverse events other than RBO occurred as follows: Acute cholecystitis, post-ERCP pancreatitis, hemobilia, and fever without exacerbation of liver injury, and liver abscess in 4 (10.3%), 3 (7.9%), 2 (5.3%), 1 (2.6%), and 1 (2.6%), respectively. Migration of the stents was not observed. Niti-S 14 is considered to be a preferable metal stent because of a low rate of RBO with no migration.

  18. Comparison of biolimus eluted from an erodible stent coating with bare metal stents in acute ST-elevation myocardial infarction (COMFORTABLE AMI trial): rationale and design

    NARCIS (Netherlands)

    Räber, L.; von Birgelen, Clemens

    2012-01-01

    Aims: Compared with bare metal stents (BMS), early generation drug-eluting stents (DES) reduce the risk of revascularisation in patients with ST-elevation myocardial infarction (STEMI) at the expense of an increased risk of very late stent thrombosis (ST). Durable polymer coatings for controlled

  19. Biodegradable Metals for Cardiovascular Stents: from Clinical Concerns to Recent Zn-Alloys.

    Science.gov (United States)

    Bowen, Patrick K; Shearier, Emily R; Zhao, Shan; Guillory, Roger J; Zhao, Feng; Goldman, Jeremy; Drelich, Jaroslaw W

    2016-05-01

    Metallic stents are used to promote revascularization and maintain patency of plaqued or damaged arteries following balloon angioplasty. To mitigate the long-term side effects associated with corrosion-resistant stents (i.e., chronic inflammation and late stage thrombosis), a new generation of so-called "bioabsorbable" stents is currently being developed. The bioabsorbable coronary stents will corrode and be absorbed by the artery after completing their task as vascular scaffolding. Research spanning the last two decades has focused on biodegradable polymeric, iron-based, and magnesium-based stent materials. The inherent mechanical and surface properties of metals make them more attractive stent material candidates than their polymeric counterparts. A third class of metallic bioabsorbable materials that are based on zinc has been introduced in the last few years. This new zinc-based class of materials demonstrates the potential for an absorbable metallic stent with the mechanical and biodegradation characteristics required for optimal stent performance. This review compares bioabsorbable materials and summarizes progress towards bioabsorbable stents. It emphasizes the current understanding of physiological and biological benefits of zinc and its biocompatibility. Finally, the review provides an outlook on challenges in designing zinc-based stents of optimal mechanical properties and biodegradation rate. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Usefulness of a hook in nasolacrimal balloon dilatation and stent placement

    International Nuclear Information System (INIS)

    Kim, Tae Hyung; Song, Ho Young; Son, Jin Hyun; Park, Sang Soo

    1996-01-01

    To evaluate the usefulness of a hook developed for pulling out the guide wire in nasolacrimal balloon dilatation and stent placement. The head was made of stainless steel wire in a shape of a question mark, and the body was made of four stainless steel pipes. The head was attached to the body in three different ways:A) the head was anterior to the body, B) the head was posterior to the body, and C) the head was angled of 30 degrees forward from the direction of the body. 90 epiphora patients took part in a test to compare and evalvate the usefulness of different types of hook. Average number of trials, success rate and average time of the procedure were recorded. The average trial number for different attachment methods A, B, and C was 4.5, 6.4, and 2.5, respectively, and the success rate 83, 70, and 97%, respectively. The average time of the procedure was 31 minutes. The C type hook was the most effective, and the new technique using the hook was more convenient and time-saving than the old technique using a nasal endoscopy

  1. Memokath Metallic Stent in the Treatment of Transplant Kidney Ureter Stenosis or Occlusion

    International Nuclear Information System (INIS)

    Boyvat, Fatih; Aytekin, Cuneyt; Colak, Turan; Firat, Ali; Karakayali, Hamdi; Haberal, Mehmet

    2005-01-01

    Purpose. To determine the efficacy of the Memokath 051 stent (Engineers and Doctors, Hornbaek, Denmark) in the treatment of recurrent ureteral stenosis or occlusion in transplant kidneys. Methods. From October 1985 through January 2004, 1,131 renal transplantations were performed at our center. Four patients who developed recurrent renal transplant ureter obstruction had nephrostomy catheters placed. Antegrade pyelography showed ureteral stenosis in three cases and complete occlusion in one patient. In each case, a Memokath 051 stent was inserted via an antegrade approach. Mean follow-up was 20 months (range 18-21 months). Creatinine levels were measured and ultrasonography was performed during follow-up. Results. All stent procedures were technically successful. During follow-up, one stent migrated within 10 days after stent insertion and was removed cystoscopically. Another stent had to be removed in the 14th month due to resistant infection, and was replaced with a new Memokath 051 stent which remained patent for another 8 months. The other two stents were fully patent at the 18th and 21st month of follow-up, respectively. Conclusion. Placement of a Memokath 051 stent appears to be a promising treatment alternative to balloon dilation, double-J stents and open surgical intervention for ureteral stenosis or occlusion in kidney transplant recipients. Further study of larger series is necessary

  2. [Renal artery stenosis after transplantation: treatment using percutaneous transluminal angioplasty and placement of an expandable metal luminal prosthesis].

    Science.gov (United States)

    Guzmán-Rodríguez, J Hugo; Plata-Muñoz, Juan José; Mancilla, Eduardo; Dorantes, Joel; Narváez, René; Martínez, Raúl; Tielve, Manuel; Bezaury, Paulina; Correa-Rotter, Ricardo; Alberú, Josefina

    2003-01-01

    Transplant renal artery stenosis (TRAS) is a cause of severe post transplant hypertension with a widely variable reported incidence from 1 to 25%. We herein report 3 cases of endoluminal stent placement after percutaneous transluminal angioplasty for treatment of TRAS. Clinical and laboratory findings during their follow-up, suggestive of TRAS included: elevated mean blood pressure, bruit over the graft area(2/3), and increase in serum creatinine (2/3). Doppler sonography, radioisotope renography and arteriography were performed to confirm TRAS diagnosis. The series includes 2 female and 1 male patients; the time elapsed between transplantation and TRAS diagnosis was 25 d, 12 and 65 months, respectively. All grafts were from living related donors. Patients received at least 3 antihypertensive drugs without adequate blood pressure control. Vascular anastomosis was end to end from the renal to the hypogastric artery in two cases, and end to side to the external iliac artery in the other one. After the diagnosis of TRAS, percutaneous transluminal angioplasty with endoluminal metallic Palmaz stent placement was accomplished in the three cases. No complications occurred during or after the procedures. Beneficial clinical results were obtained in all cases documented by a decrease in both: serum creatinine, and mean blood pressure. Average follow-up after stent placement was 13, 19 and 36 months, respectively without evidence of stenosis recurrence Percutaneous transluminal angioplasty with stent placement is a safe and effective treatment for TRAS associated hypertension and renal dysfunction. Extended follow-up is necessary to evaluate long-term efficacy and safety of this procedure.

  3. The application of DynaCT in performing the placement of intracranial stent

    International Nuclear Information System (INIS)

    Shen Hui; Wang Yongchun; Wang Minjie; Ding Hailing; Qin Yashan; Mao Yaqin; Li Songhua; Mao Yanjun; Hao Qiang

    2011-01-01

    Objective: To evaluate the clinical application of DynaCT technique in performing intracranial stent implantation. Methods: Thirty-nine patients who were planed to receive intracranial stent implantation were involved in this study. During the procedure DynaCT scanning was employed to monitor the real-time situation of stent implantation. Results: A total of 47 stents were implanted in intracranial vessels in the 39 patients. By using conventional angiography during operation the position of these stents was observed and was assured to be in the proper position. The adherence of these stents to the vascular wall was demonstrated with DynaCT multi-planar reconstruction images and the stent adherence in good condition was ensured. Conclusion: DynaCT applied during and after intracranial stent implantation is very helpful for displaying the contours of the stents as well as the vascular lumen and for providing a detail picture of the relationship between the stent and the surrounding anatomy. Therefore, DynaCT scanning is of great clinical significance for performing the intracranial stent implantation. (authors)

  4. Transurethral resection of fibrotic scar tissue combined with temporary urethral stent placement for patients with in anterior urethral stricture

    Directory of Open Access Journals (Sweden)

    Cheol Yong Yoon

    2014-08-01

    Full Text Available Introduction Fibrotic scar formation is a main cause of recurrent urethral stricture after initial management with direct vision internal urethrotomy (DVIU. In the present study, we devised a new technique of combined the transurethral resection of fibrotic scar tissue and temporary urethral stenting, using a thermo-expandable urethral stent (MemokathTM 044TW in patients with anterior urethral stricture. Materials and Methods As a first step, multiple incisions were made around stricture site with cold-cutting knife and Collins knife electrode to release a stricture band. Fibrotic tissue was then resected with a 13Fr pediatric resectoscope before deployment of a MemokathTM 044TW stent (40 – 60mm on a pre-mounted sheath using 0° cystoscopy. Stents were removed within 12 months after initial placement. Results We performed this technique on 11 consecutive patients with initial (n = 4 and recurrent (n = 7 anterior urethral stricture (April 2009 – February 2013. At 18.9 months of mean follow-up (12-34 months, mean Qmax (7.8±3.9ml/sec vs 16.8 ± 4.8ml/sec, p < 0.001, IPSS (20.7 vs 12.5, p = 0.001 , and QoL score (4.7 vs 2.2, p < 0.001 were significantly improved. There were no significant procedure-related complications except two cases of tissue ingrowth at the edge of stent, which were amenable by transurethral resection. In 7 patients, an average 1.4 times (1-5 times of palliative urethral dilatation was carried out and no patients underwent open surgical urethroplasty during the follow-up period. Conclusion Combined transurethral resection and temporary urethral stenting is a effective therapeutic option for anterior urethral stricture. Further investigations to determine the long-term effects, and safety profile of this new technique are warranted.

  5. Long-Term Results of Stent Placement in Patients with Outflow Block After Living-Donor-Liver Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Fujimori, Masashi, E-mail: fujimorim@clin.medic.mie-u.ac.jp [Mie University School of Medicine, Department of Radiology (Japan); Yamakado, Koichiro, E-mail: yamakado47@gmail.com; Takaki, Haruyuki, E-mail: takaki-h@clin.medic.mie-u.ac.jp [Hyogo College of Medicine, Department of Radiology (Japan); Nakatsuka, Atsuhiro, E-mail: nakatuka@clin.medic.mie-u.ac.jp; Uraki, Junji, E-mail: junji@clin.medic.mie-u.ac.jp; Yamanaka, Takashi, E-mail: t-yama@clin.medic.mie-u.ac.jp; Hasegawa, Takaaki, E-mail: hasegawat@clin.medic.mie-u.ac.jp; Sugino, Yuichi, E-mail: ysugino23@clin.medic.mie-u.ac.jp; Nakajima, Ken, E-mail: k-nakajima@clin.medic.mie-u.ac.jp; Matsushita, Naritaka, E-mail: n-matsushita@clin.medic.mie-u.ac.jp [Mie University School of Medicine, Department of Radiology (Japan); Mizuno, Shugo, E-mail: mizunos@clin.medic.mie-u.ac.jp [Mie University School of Medicine, Hepatobiliary Pancreatic and Transplant Surgery (Japan); Sakuma, Hajime, E-mail: sakuma.mie@gmail.com [Mie University School of Medicine, Department of Radiology (Japan); Isaji, Shuji, E-mail: isaji-s@clin.medic.mie-u.ac.jp [Mie University School of Medicine, Hepatobiliary Pancreatic and Transplant Surgery (Japan)

    2016-04-15

    PurposeTo evaluate long-term results of stent placement retrospectively in patients with outflow block after living-donor-liver transplantation (LDLT).Materials and MethodsFor this institutional review board approved retrospective study conducted during 2002–2012, stents were placed in outflow veins in 15 patients (11.3 %, 15/133) (12 men; 3 female) in whom outflow block developed after LDLT. Their mean age was 52.3 years ± 15.3 (SD) (range, 4–69 years). Venous stenosis with a pressure gradient ≥5 mmHg (outflow block) was observed in the inferior vena cava in seven patients, hepatic vein in seven patients, and both in one patient. Technical success, change in a pressure gradient and clinical manifestations, and complications were evaluated. Overall survival of 15 patients undergoing outflow block stenting was compared with that of 116 patients without outflow block after LDLT.ResultsStents were placed across the outflow block veins without complications, lowering the pressure gradient ≤ 3 mmHg in all patients (100 %, 15/15). Clinical manifestations improved in 11 patients (73.3 %, 11/15), and all were discharged from the hospital. However, they did not improve in the other 4 patients (26.7 %, 4/15) who died in the hospital 1.0–3.7 months after stenting (mean, 2.0 ± 1.2 months). No significant difference in 5-year survival rates was found between patients with and without outflow block after LDLT (61.1 vs. 72.2 %, p = .405).ConclusionStenting is a feasible, safe, and useful therapeutic option to resolve outflow block following LDLT, providing equal survival to that of patients without outflow block.

  6. Safety and efficacy of coaxial lumen-apposing metal stents in the management of refractory gastrointestinal luminal strictures: a multicenter study

    Science.gov (United States)

    Bazerbachi, Fateh; Heffley, Jason D.; Abu Dayyeh, Barham K.; Nieto, Jose; Vargas, Eric J.; Sawas, Tarek; Zaghlol, Raja; Buttar, Navtej S.; Topazian, Mark D.; Wong Kee Song, Louis M.; Levy, Michael; Keilin, Steve; Cai, Qiang; Willingham, Field F.

    2017-01-01

    Background and aims  Benign gastrointestinal (GI) strictures are often refractory to standard endoscopic interventions. Fully covered coaxial lumen-apposing metal stents (LAMS) have emerged as a novel therapy for these strictures. The aim of this study was to evaluate the safety and efficacy of LAMS for refractory GI strictures. Patients and methods  A retrospective analysis was performed for patients who underwent LAMS placement for benign luminal strictures in three US centers between January 2014 and December 2016. The primary outcomes were technical success and initial clinical success of LAMS placement. Secondary outcomes were stent migration, rate of re-intervention, and adverse events. Results  A total of 49 patients underwent 56 LAMS placement procedures. Previous treatment had failed in 39 patients (79.6 %), and anastomotic strictures were the indication in 77.6 % (38/49), with the most common site being gastrojejunal (34.7 % [17/49]). Technical success was achieved in all procedures and initial clinical success was achieved in 96.4 % of all procedures (54/56). Patient initial clinical success was 95.9 % (47/49). Stent migration occurred in 17.9 % of procedures, and was more likely to occur at sites in the lower GI tract ( P  = 0.02). The mean stent dwell time was 100.6 days, and the mean follow-up was 169.8 days. Minor adverse events, not requiring hospitalization, occurred in 33.9 % of procedures, including subsequent stricture progression (10.7 %). In cases where LAMS were removed, mean follow-up time was 102.2 days. The re-intervention rate was 75 % at 300 days follow-up after stent removal. Of the LAMS placed at anastomotic strictures, 36.4 % required re-intervention, with approximately two-thirds of these re-interventions requiring placement of a new stent or surgery. Conclusion  LAMS placement was successful for the management of refractory GI strictures, with good technical and initial clinical success rates

  7. Delay of surgery after stent placement for resectable malignant colorectal obstruction is associated with higher risk of recurrence

    DEFF Research Database (Denmark)

    Broholm, Malene; Kobborg, Martin; Frostberg, Erik

    2017-01-01

    BACKGROUND: Self-expanding metal stents can be used as bridge to elective surgery for acute malignant colonic obstruction. However, the impact on long-term oncological outcome and the optimal timing of surgery are still unknown. METHOD: This was a retrospective multicenter study performed at four...

  8. Flexible bronchoscopic insertion of self-expanding metal stents in malignant tracheal lesions without fluoroscopic guidance

    Directory of Open Access Journals (Sweden)

    Karan Madan

    2016-01-01

    Full Text Available Background: Self-expanding metal stents (SEMS are a well-accepted treatment modality for malignant tracheobronchial obstruction or malignant tracheoesophageal fistulae (TEFs. The traditional approach to SEMS insertion in central airway obstruction (CAO has been rigid bronchoscopy performed under general anesthesia. Fluoroscopic guidance is sometimes utilized. Safe and accurate placement of tracheobronchial SEMS has also been described using flexible bronchoscopy. We herein describe our experience with tracheal SEMS insertion using flexible bronchoscopy without fluoroscopic guidance. Methods: A retrospective analysis of the bronchoscopy records was undertaken for the duration June 2012 to June 2014. Patients with malignant CAO or malignant TEF who underwent tracheal SEMS insertion using flexible bronchoscopy were included. Procedures were performed under mild sedation. Fluoroscopic guidance was not utilized. Results: Eleven patients were identified. The mean age was 60.9 (12.8 years. There were 6 males and 5 female patients. Most common indication for tracheal SEMS was CAO (9/11 followed by TEF (2/11. Stent deployment could be accomplished successfully and at the desired location in all the patients. All patients reported immediate symptomatic relief. Two patients experienced peri-procedural respiratory failure that recovered within 24 h. There was no procedure related mortality or other major complications. Conclusion: Insertion of tracheal SEMS in patients with malignant CAO/TEF using flexible bronchoscopy under minimal sedation is a safe and efficacious modality that can be performed without fluoroscopic guidance.

  9. Endoscopic Therapy With Lumen-apposing Metal Stents Is Safe and Effective for Patients With Pancreatic Walled-off Necrosis.

    Science.gov (United States)

    Sharaiha, Reem Z; Tyberg, Amy; Khashab, Mouen A; Kumta, Nikhil A; Karia, Kunal; Nieto, Jose; Siddiqui, Uzma D; Waxman, Irving; Joshi, Virendra; Benias, Petros C; Darwin, Peter; DiMaio, Christopher J; Mulder, Christopher J; Friedland, Shai; Forcione, David G; Sejpal, Divyesh V; Gonda, Tamas A; Gress, Frank G; Gaidhane, Monica; Koons, Ann; DeFilippis, Ersilia M; Salgado, Sanjay; Weaver, Kristen R; Poneros, John M; Sethi, Amrita; Ho, Sammy; Kumbhari, Vivek; Singh, Vikesh K; Tieu, Alan H; Parra, Viviana; Likhitsup, Alisa; Womeldorph, Craig; Casey, Brenna; Jonnalagadda, Sreeni S; Desai, Amit P; Carr-Locke, David L; Kahaleh, Michel; Siddiqui, Ali A

    2016-12-01

    Endoscopic ultrasound-guided transmural drainage and necrosectomy have become the standard treatment for patients with pancreatic walled-off necrosis (WON). Lumen-apposing metal stents (LAMS) have shown success in the management of pancreatic fluid collections. However, there are few data on their specific roles in management of WON. We investigated the efficacy and safety of LAMS in treatment of WON. We performed a retrospective multicenter case series of 124 patients with WON who underwent endoscopic transmural drainage by using LAMS at 17 tertiary care centers from January 2014 through May 2015. Patients underwent endoscopic ultrasound-guided cystogastrostomy or cystoenterostomy with placement of an LAMS into the WON collection. At the discretion of the endoscopist, we performed direct endoscopic necrosectomy, irrigation with hydrogen peroxide, and/or nasocystic drain placement. We performed endoscopic retrograde cholangiopancreatography with pancreatic duct stent placement when indicated. Concomitant therapies included direct endoscopic debridement (n = 78), pancreatic duct stent placement for leak (n = 19), hydrogen peroxide-assisted necrosectomy (n = 38), and nasocystic irrigation (n = 22). We collected data for a median time of 4 months (range, 1-34 months) after the LAMS placement. The primary outcomes were rates of technical success (successful placement of the LAMS), clinical success (resolution of WON, on the basis of image analysis, without need for further intervention via surgery or interventional radiology), and adverse events. The median size of the WON was 9.5 cm (range, 4-30 cm). Eight patients had 2 LAMS placed for multiport access, all with technical success (100%). Clinical success was achieved in 107 patients (86.3%) after 3 months of follow-up. Thirteen patients required a percutaneous drain, and 3 required a surgical intervention to manage their WON. The stents remained patent in 94% of patients (117 of 124) and migrated in 5.6% of

  10. Palliative gastrojejunostomy versus endoscopic stent placement for gastric outlet obstruction in patients with unresectable gastric cancer: a propensity score-matched analysis.

    Science.gov (United States)

    Jang, Seung Hyeon; Lee, Hyuk; Min, Byung-Hoon; Kim, Su Mi; Kim, Hye Seung; Carriere, Keumhee C; Min, Yang Won; Lee, Jun Haeng; Kim, Jae J

    2017-10-01

    It remains unclear whether selection of treatment modality affects the survival of patients with malignant gastric outlet obstruction (GOO). We compared the effect of gastrojejunostomy (GJ) and endoscopic self-expandable metallic stent (SEMS) placement on the long-term outcomes of patients with malignant GOO caused by unresectable gastric cancer. We conducted a retrospective study of gastric cancer patients undergoing GJ or endoscopic SEMS placement for the palliation of malignant GOO. To reduce the effect of selection bias, we performed a propensity score-matching analysis between two groups. In a propensity-matched analysis (45 and 99 in GJ and SEMS groups, respectively), clinical success rates were comparable between the GJ and SEMS groups (95.6 and 96.0%), while the SEMS group showed significantly shorter hospital stays than the GJ group. The GJ group showed a significantly longer reintervention period and overall survival (393 and 129 days) compared to the SEMS group. In multivariate Cox regression analysis, GJ, low ECOG scale (good performance status), and additional chemo- or radiation therapy were identified as independent favorable predictors of overall survival. GJ was also identified as an independent protective predictor against reintervention. We found that palliative GJ was significantly associated with longer overall survival and lower risk of reintervention than SEMS placement in patients with malignant GOO caused by unresectable gastric cancer. Given very limited expected survival in selected patients with unresectable gastric cancer and more favorable short-term outcomes in cases of SEMS placement, individualized approach might be required in treatment decision between palliative GJ and SEMS placement.

  11. Metallic stent implantation in the treatment of malignant tracheal stenosis under general anaesthesia

    International Nuclear Information System (INIS)

    Bai Xuming; Jin Yong; Xie Hong; Cheng Long; Gu Xingshi; Chang Liuhui

    2012-01-01

    Objective: To evaluate the safety and feasibility of the tracheal stent implantation for treatment of malignant tracheal stenosis under general anaesthesia. Methods: Eighteen patients with malignant tracheal stenosis underwent preoperative 64-slice spiral CT scan and airway reconstruction. The stenotic sites were located in main tracheal trunk (5 patients), in right main bronchus (1 patient), in trachea and left main bronchus (4 patients), in trachea and right main bronchus (3 patients), in main tracheal trunk and bilateral main bronchus (5 patients). The degree of stenosis was rated 51% to 70% in 7 cases, 71% to 90% in 11 cases. All patients, 17 patients of ASA grade Ⅳ and 1 patient of grade Ⅲ, presented with severe dyspnea. Under general anaesthesia, implantation of metallic stent was performed through the sputum aspiration hole of the connecting tubing with DSA guidance. The NBP, ECG, RR, SaO 2 of the patients were recorded and compared with t test during the entire procedure. At the end of the procedure, relief of dyspnea, complications related to anesthesia and operation were recorded. Results: The success rate of stent placement was 18/18, and dyspnea was significantly relived in all patients. Slightly bloody sputum occurred in 7 cases. The stent was obstructed by sputum in 1 case,and the patient was treated with medication. There were no severe complications. The operative course were rated 11 to 9 in 17 cases, and 6 to 8 in 1 case. All 18 patients were cooperative during the procedure. Sixteen patients rated the procedure as very comfortable and 2 rated the procedure as comfortable. Respiratory rate (RR) and heart rate (HR) decreased in all patients after the operation [(37.1 ± 2.8)/min and (106.5 ± 14.2) bpm before the operation respectively, (18.6 ± 1.4)/min and (73.2 ± 7.6) bpm after the operation respectively], t=17.81 and 3.80, P<0.01. Pulse oxygen saturation (SaO 2 ) during the operation [(91.2 ± 1.8)%]increased [(76.3 ± 8.6 )% before the

  12. Outcomes of Prosthetic Hemodialysis Grafts after Deployment of Bare Metal versus Covered Stents at the Venous Anastomosis

    International Nuclear Information System (INIS)

    Kim, Charles Y.; Tandberg, Daniel J.; Rosenberg, Michael D.; Miller, Michael J.; Suhocki, Paul V.; Smith, Tony P.

    2012-01-01

    Purpose: To compare postintervention patency rates after deployment of bare metal versus covered stents across the venous anastomosis of prosthetic arteriovenous (AV) grafts. Methods: Review of our procedural database over a 6 year period revealed 377 procedures involving stent deployment in an AV access circuit. After applying strict inclusion criteria, our study group consisted of 61 stent deployments in 58 patients (median age 58 years, 25 men, 33 women) across the venous anastomosis of an upper extremity AV graft circuit that had never been previously stented. Both patent and thrombosed AV access circuits were retrospectively analyzed. Within the bare metal stent group, 20 of 32 AV grafts were thrombosed at initial presentation compared to 18 of 29 AV grafts in the covered stent group. Results: Thirty-two bare metal stents and 29 covered stents were deployed across the venous anastomosis. The 3, 6, and 12 months primary access patency rates for bare metal stents were not significantly different than for covered stents: 50, 41, and 22 % compared to 59, 52, and 29 %, respectively (p = 0.21). The secondary patency rates were also not significantly different: 78, 78, and 68 % for bare metal stents compared to 76, 69, and 61 % for covered stents, respectively (p = 0.85). However, covered stents demonstrated a higher primary stent patency rate than bare metal stents: 100, 85, and 70 % compared to 75, 67, and 49 % at 3, 6, and 12 months (p < 0.01). Conclusion: The primary and secondary access patency rates after deployment of bare metal versus covered stents at the venous anastomosis were not significantly different. However, bare metal stents developed in-stent stenoses significantly sooner.

  13. The effectiveness of ureteric metal stents in malignant ureteric obstructions: A systematic review.

    Science.gov (United States)

    Kallidonis, Panagiotis; Kotsiris, Dimitrios; Sanguedolce, Francesco; Ntasiotis, Panteleimon; Liatsikos, Evangelos; Papatsoris, Athanasios

    2017-12-01

    To review the literature on the effectiveness, safety and long-term patency of ureteric metal mesh stents (MSs), as a variety of MSs have been used for managing malignant ureteric obstruction over the last three decades. A systematic review using the search string; Ureter∗ AND (stent OR endoprosthesis) AND metal∗ was conducted on PubMed, Scopus, Web of science and Cochrane Library online databases in May 2016. Prospective, retrospective, and comparative studies including MSs were included. The primary endpoint was the patency rate and the secondary endpoint was complications. In all, 324 publications were screened and 31 articles were included in the systematic review; 21 prospective and 10 retrospective studies. These studies reported the effectiveness of specific MSs in population studies, in comparative studies among different MSs, as well as among MSs and JJ stents. It should be noted that all comparative studies were retrospective. The experiences with vascular MSs, such as the Wallstent™ (Boston Scientific/Microvasive, Natick, MA, USA), were related to high occlusion rates, due to endoluminal hyperplasia, and long-term disappointing patency. The use of covered MSs designed for the vascular system was also unfavourable. The Memokath 051™ (PNN Medical A/S, Kvistgaard, Denmark) had better patency rates, but also higher migration rates. The long-term results were acceptable and rendered the Memokath 051 as a viable option for the management of malignant ureteric obstruction. The Uventa™ (Taewoong Medical, Seoul, Korea) and Allium™ (Allium Medical Solutions Ltd, Caesarea, Israel) MSs, specifically designed for ureteric placement, provided promising results. Nevertheless, the wide acceptance of these MSs would require well-designed clinical studies and long-term follow-up.

  14. Coronary stent restenosis and the association with allergy to metal content of 316L stainless steel.

    Science.gov (United States)

    Slodownik, D; Danenberg, C; Merkin, D; Swaid, F; Moshe, S; Ingber, A; Lotan, H; Durst, R

    Most intra-coronary stents in use are made of 316 L stainless steel, which contains nickel, chromate and molybdenum. Whether inflammatory and allergic reactions to metals contribute to in-stent restenosis is still a matter of debate. The aim of this study was to ascertain the relationship between metal allergy and the occurrence of in-stent restenosis. Ninety-nine adult patients who underwent two cardiac catheterisations, up to two years apart, were included in the study. Seventy patients had patent stents at the second angiogram (patent stent group) and 29 were found to have in-stent restenosis (restenosis group). All patients underwent patch testing with the relevant metals and the 316L stainless steel plate. Twenty-eight (28.3%) patients were found to have an allergy to at least one metal. There was no significant difference in the prevalence of metal allergy between the patent stent group and the restenosis group (28.6 and 27.6%, respectively; p = 0.921). Our data do not support the theory that contact allergy plays a role in the pathogenesis of in-stent restenosis.

  15. Efficacy of endoscopic management of leak after foregut surgery with endoscopic covered self-expanding metal stents (SEMS).

    Science.gov (United States)

    Aryaie, Amir H; Singer, Jordan L; Fayezizadeh, Mojtaba; Lash, Jon; Marks, Jeffrey M

    2017-02-01

    Anastomotic or staple-line leak after foregut surgery presents a formidable management challenge. In recent years, with advancement of endoscopy, self-expanding covered stents have been gaining popularity. In this study, we aimed to determine the safety and effectiveness of self-expanding covered stents in management of leak after foregut surgery. Consecutive patients who received a fully covered self-expandable metal stent (SEMS) due to an anastomotic leak after upper gastrointestinal surgery between 2009 and 2014 were retrospectively reviewed. Demographic data, stent placement and removal, clinical success, time to resolution, and complications were collected. Predictive factors for clinical success rate were assessed. A total of 20 consecutive patients underwent placement of fully covered SEMS for anastomotic leak, following esophagectomy (n = 5), esophageal diverticulectomy (n = 1), gastric sleeve (n = 4), gastric bypass (n = 3), partial gastrectomy (n = 4), and total gastrectomy (n = 3). All the stents were removed successfully, and clinical resolution was achieved in 18 patients (90 %) after a median of two (range 1-3) procedures and a mean of 6.2 weeks (range 0.4-14). Complications presented in 12 patients (60 %), including stent migration (n = 8), mucosal friability (n = 4), tissue integration (n = 2), and bleeding (n = 2). Two (10 %) patients' treatment was complicated by aorto-esophageal fistula formation resulting in one death. Demographic factors, comorbidities, and type of surgery were not predictive of clinical success rate or time to resolution. SEMS are effective tools for the management of leaks after foregut surgery. The biggest challenge with this approach is stent migration. Caution is warranted due to the risk of fatal complications such as aorto-esophageal fistula formation. No type of surgery or particular patient factor, including age, sex, BMI, albumin, history of radiation, malignancy, and comorbid diabetes or

  16. Spectral Analysis Related to Bare-Metal and Drug-Eluting Coronary Stent Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Rose Mary Ferreira Lisboa da, E-mail: roselisboa@cardiol.br [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil); Silva, Carlos Augusto Bueno [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil); Belo Horizonte, Hospital São João de Deus, Divinópolis, MG (Brazil); Greco, Otaviano José [Belo Horizonte, Hospital São João de Deus, Divinópolis, MG (Brazil); Moreira, Maria da Consolação Vieira [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil)

    2014-08-15

    The autonomic nervous system plays a central role in cardiovascular regulation; sympathetic activation occurs during myocardial ischemia. To assess the spectral analysis of heart rate variability during stent implantation, comparing the types of stent. This study assessed 61 patients (mean age, 64.0 years; 35 men) with ischemic heart disease and indication for stenting. Stent implantation was performed under Holter monitoring to record the spectral analysis of heart rate variability (Fourier transform), measuring the low-frequency (LF) and high-frequency (HF) components, and the LF/HF ratio before and during the procedure. Bare-metal stent was implanted in 34 patients, while the others received drug-eluting stents. The right coronary artery was approached in 21 patients, the left anterior descending, in 28, and the circumflex, in 9. As compared with the pre-stenting period, all patients showed an increase in LF and HF during stent implantation (658 versus 185 ms2, p = 0.00; 322 versus 121, p = 0.00, respectively), with no change in LF/HF. During stent implantation, LF was 864 ms2 in patients with bare-metal stents, and 398 ms2 in those with drug-eluting stents (p = 0.00). The spectral analysis of heart rate variability showed no association with diabetes mellitus, family history, clinical presentation, beta-blockers, age, and vessel or its segment. Stent implantation resulted in concomitant sympathetic and vagal activations. Diabetes mellitus, use of beta-blockers, and the vessel approached showed no influence on the spectral analysis of heart rate variability. Sympathetic activation was lower during the implantation of drug-eluting stents.

  17. First magnetic resonance imaging-guided aortic stenting and cava filter placement using a polyetheretherketone-based magnetic resonance imaging-compatible guidewire in swine: proof of concept.

    Science.gov (United States)

    Kos, Sebastian; Huegli, Rolf; Hofmann, Eugen; Quick, Harald H; Kuehl, Hilmar; Aker, Stephanie; Kaiser, Gernot M; Borm, Paul J A; Jacob, Augustinus L; Bilecen, Deniz

    2009-05-01

    The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. The guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.

  18. First Magnetic Resonance Imaging-Guided Aortic Stenting and Cava Filter Placement Using a Polyetheretherketone-Based Magnetic Resonance Imaging-Compatible Guidewire in Swine: Proof of Concept

    International Nuclear Information System (INIS)

    Kos, Sebastian; Huegli, Rolf; Hofmann, Eugen; Quick, Harald H.; Kuehl, Hilmar; Aker, Stephanie; Kaiser, Gernot M.; Borm, Paul J. A.; Jacob, Augustinus L.; Bilecen, Deniz

    2009-01-01

    The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. The guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.

  19. Effects of cobalt-chromium everolimus eluting stents or bare metal stent on fatal and non-fatal cardiovascular events

    DEFF Research Database (Denmark)

    Valgimigli, Marco; Sabaté, Manel; Kaiser, Christoph

    2014-01-01

    coronary syndrome v stable coronary artery disease), diabetes mellitus, female sex, use of glycoprotein IIb/IIIa inhibitors, and up to one year v longer duration treatment with dual antiplatelets. CONCLUSIONS: This meta-analysis offers evidence that compared with bare metal stents the use of cobalt...

  20. Drug-eluting versus bare-metal stents in large coronary arteries

    DEFF Research Database (Denmark)

    Kaiser, Christoph; Galatius, Soeren; Erne, Paul

    2010-01-01

    Recent data have suggested that patients with coronary disease in large arteries are at increased risk for late cardiac events after percutaneous intervention with first-generation drug-eluting stents, as compared with bare-metal stents. We sought to confirm this observation and to assess whether...

  1. Very late bare-metal stent thrombosis, rare but stormy!

    LENUS (Irish Health Repository)

    Ali, Mohammed

    2011-08-01

    Recurrent in-stent thrombosis is rarely reported, with catastrophic clinical consequences of either acute coronary syndrome or death. We present a case of recurrent in-stent thrombosis with its outcome and a concise literature review.

  2. Biocompatibility properties of a new braided biodegradable urethral stent: a comparison with a biodegradable spiral and a braided metallic stent in the rabbit urethra.

    Science.gov (United States)

    Isotalo, Taina M; Nuutine, Juha-Pekka; Vaajanen, Anu; Martikainen, Paula M; Laurila, Marita; Törmälä, Pertti; Talja, Martti; Tammela, Teuvo L

    2006-04-01

    To compare the biocompatibility properties of a new braided biodegradable self-reinforced poly-L-lactic acid (SR-PLLA) urethral stent to the former spiral biodegradable SR-PLLA stent and the stainless steel stent in a rabbit model. In all, 54 male New Zealand White rabbits were anaesthetized and stents inserted into the prostatic urethra, three of each kind for each sample time. The rabbits were killed after 1, 3, 6, 9, 12 or 15 months and light microscopy and scanning electron microscopy used to analyse the effects. The disintegration of the braided SR-PLLA stent was more closely controlled than that of the spiral SR-PLLA stent. The metallic stent induced epithelial hyperplasia and polyposis earlier than the biodegradable stents, and in these rabbits the polyposis disappeared after the disintegration process. There were no differences in the histological analyses between the biodegradable stents, whereas the metallic stents caused the strongest inflammatory reactions. The braided SR-PLLA urethral stent functioned well in the rabbit urethra and clinical studies are already planned.

  3. Long-Term Efficacy of Percutaneous Internal Plastic Stent Placement for Non-anastomotic Biliary Stenosis After Liver Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Sun, E-mail: seraph377@gmail.com; Han, Joon Koo, E-mail: hanjk@snu.ac.kr; Baek, Ji-Hyun, E-mail: 100paper@gmail.com [Seoul National University Hospital, Department of Radiology (Korea, Republic of); Suh, Suk-Won, E-mail: bomboy1@hanmail.net [Chung-Ang University Hospital, Department of Surgery (Korea, Republic of); Joo, Ijin, E-mail: hijijin@gmail.com [Seoul National University Hospital, Department of Radiology (Korea, Republic of); Yi, Nam-Joon, E-mail: gsleenj@hanmail.net; Lee, Kwang-Woong, E-mail: kwleegs@gmail.com; Suh, Kyung-Suk, E-mail: kssuh@snu.ac.kr [Seoul National University Hospital, Department of Surgery (Korea, Republic of)

    2016-06-15

    PurposeWe aimed to evaluate the long-term efficacy of percutaneous management of non-anastomotic biliary stenosis after liver transplantation, using plastic internal biliary stents.Materials and MethodsThis study included 35 cases (28 men, 7 women; mean age: 52.09 ± 8.13 years, range 34–68) in 33 patients who needed repeated interventional procedures because of biliary strictures. After classification of the biliary strictures, we inserted percutaneous biliary plastic stents through the T-tube or percutaneous transhepatic biliary drainage tracts. Stents were exchanged according to percutaneous methods at regular 2- to 6-month intervals. The stents were removed if the condition improved, as observed on cholangiogram as well as based on clinical findings. The median patient follow-up period after initial diagnosis and treatment was 6.04 years (range 0.29–9.95 years). We assessed treatment success rate and patient and graft survival times.ResultsDuring the follow-up period, 14 patients (14/33, 42.42 %) were successfully treated and were tube-free. The median tube-free time, time without a stent, was 4.13 years (range 1.00–9.01). In contrast, internal plastic stents remained in 9 patients (9/33, 27.27 %) until the last follow-up. These patients had acceptable hepatic function. Among the remaining 10 patients, 3 (3/33, 9.09 %) were lost to regular follow-up and the other 7 (7/33, 21.21 %) patients died. The overall graft loss rate was 20.0 % (7/35). The median time from initial treatment to graft loss was 1.84 years (range 0.42–4.25).ConclusionsPercutaneous plastic stents placement is technically feasible and clinically useful in patients with multiple biliary stenoses following liver transplantation.

  4. Clinical outcomes with drug-eluting and bare-metal stents in patients with ST-segment elevation myocardial infarction

    DEFF Research Database (Denmark)

    Palmerini, Tullio; Biondi-Zoccai, Giuseppe; Della Riva, Diego

    2013-01-01

    The authors investigated the relative safety and efficacy of different drug-eluting stents (DES) and bare metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI) using a network meta-analysis.......The authors investigated the relative safety and efficacy of different drug-eluting stents (DES) and bare metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI) using a network meta-analysis....

  5. Percutaneous transhepatic self-expanding metal stents for palliation ...

    African Journals Online (AJOL)

    Stent occlusion occurred in 4 patients (8%) within a week as result of stent migration (n=3) or presumed biliary sludge (n=1); 2 (4%) stents occluded between 7 days and 1 month. Four patients (8%) died during hospital admission due to pre-existing biliary sepsis (n=3) and pneumonia (n=1). Nine patients developed ...

  6. The New Nitinol Conformable Self-Expandable Metal Stents for Malignant Colonic Obstruction: A Pilot Experience as Bridge to Surgery Treatment

    Directory of Open Access Journals (Sweden)

    Roberto Di Mitri

    2014-01-01

    Full Text Available Introduction. Self-expandable metal stents (SEMS are a nonsurgical option for treatment of malignant colorectal obstruction also as a bridge to surgery approach. The new nitinol conformable stent has improved clinical outcomes in these kinds of patients. We report a pilot experience with nitinol conformable SEMS placement as bridge to surgery treatment in patients with colorectal obstruction. Materials and Methods. Between April and August 2012, we collected data on colonic nitinol conformable SEMS placement in a cohort of consecutive symptomatic patients, with malignant colorectal obstruction, who were treated as a bridge to surgery. Technical success, clinical success, and adverse events were recorded. Results. Ten patients (7 male (70%, with a mean age of 69.2 ± 10.1, were evaluated. The mean length of the stenosis was 3.6 ± 0.6 cm. Five patients (50% were treated on an emergency basis. The median time from stent placement to surgery was 16 days (interquartile range 7–21. Technical and clinical success was achieved in all patients with a significant early improvement of symptoms. No adverse events due to the SEMS placement were observed. Conclusion. This pilot study confirmed the important role of nitinol conformable SEMS as a bridge to surgery option in the treatment of symptomatic malignant colorectal obstruction.

  7. Self-expanding metal stents for the palliation of malignant gastric outlet obstruction in patients with peritoneal carcinomatosis.

    Science.gov (United States)

    Rademacher, Christoph; Bechtler, Matthias; Schneider, Steffen; Hartmann, Bettina; Striegel, Johannes; Jakobs, Ralf

    2016-11-21

    To evaluate the efficacy of self-expanding metal stents (SEMS) for the palliation of malignant gastric outlet obstruction in patients with and without peritoneal carcinomatosis (PC). We performed a retrospective analysis of 62 patients who underwent SEMS placement for treatment of malignant gastroduodenal obstruction at our hospital over a six-year period. Stents were deployed through the scope under combined fluoroscopic and endoscopic guidance. Technical success was defined as successful stent placement and expansion. Clinical success was defined as an improvement in the obstructive symptoms and discharge from hospital without additional parenteral nutrition. According to carcinomatosis status, patients were assigned into groups with or without evidence of peritoneal disease. In most cases, obstruction was caused by pancreatic (47%) or gastric cancer (23%). Technical success was achieved in 96.8% (60/62), clinical success in 79% (49/62) of all patients. Signs of carcinomatosis were identified in 27 patients (43.5%). The diagnosis was confirmed by pathology or previous operation in 7 patients (11.2%) and suspected by CT, MRI or ultrasound in 20 patients (32.2%). Presence of carcinomatosis was associated with a significantly lower clinical success rate compared to patients with no evidence of peritoneal disease (66.7% vs 88.6%, P = 0.036). There was no significant difference in overall survival between patients with or without PC (median 48 d vs 70 d, P = 0.21), but patients showed significantly longer survival after clinical success of SEMS placement compared to those experiencing clinical failure (median 14.5 d vs 75 d, P = 0.0003). Given the limited therapeutic options and a clinical success rate of at least 66.7%, we believe that SEMS are a reasonable treatment option in patients with malignant gastric outlet obstruction with peritoneal carcinomatosis.

  8. Tracheal Self-Expandable Metallic Stents: A Comparative Study of Three Different Stents in a Rabbit Model.

    Science.gov (United States)

    Serrano, Carolina; Lostalé, Fernando; Rodríguez-Panadero, Francisco; Blas, Ignacio de; Laborda, Alicia; de Gregorio, Miguel Angel

    2016-03-01

    The objective of this study was to assess tracheal reactivity after the deployment of different self-expandable metal stents (SEMS). Forty female New Zealand rabbits were divided into four groups. Three groups received three different SEMS: steel (ST), nitinol (NiTi), or nitinol drug-eluting stent (DES); the fourth group was the control group (no stent). Stents were deployed percutaneously under fluoroscopic guidance. Animals were assessed by multi-slice, computed tomography (CT) scans, and tracheas were collected for anatomical pathology (AP) study. Data from CT and AP were statistically analyzed and correlated. The DES group had the longest stenosis (20.51±14.08mm vs. 5.84±12.43 and 6.57±6.54mm in NiTi and ST, respectively, day 30; P<.05), and higher granuloma formation on CT (50% of cases). The NiTi group showed the lowest grade of stenosis (2.86±6.91% vs. 11.28±13.98 and 15.54±25.95% in DES and ST, respectively; P<.05). The AP study revealed that the ST group developed intense proliferative reactivity compared to the other groups. In the DES group, a destructive response was observed in 70% of the animals, while the NiTi was the least reactive stent. CT was more effective in detecting wall thickening (positive correlation of 68.9%; P<.001) than granuloma (not significant). The ST group developed granulomas and significant stenosis. NiTi was the least reactive stent, while DES caused significant lesions that may be related to drug dosage. This type of DES stent is therefore not recommended for the treatment of tracheobronchial stenosis. Copyright © 2015 SEPAR. Published by Elsevier Espana. All rights reserved.

  9. Drug-eluting or bare-metal stents for large coronary vessel stenting? The BASKET-PROVE (PROspective Validation Examination) trial: Study protocol and design

    DEFF Research Database (Denmark)

    Pfisterer, M.; Bertel, O.; Bonetti, P.O.

    2008-01-01

    Background Based on a subgroup analysis of 18-month BAsel Stent Kosten Effektivitats Trial (BASKET) outcome data, we hypothesized that very late (>12 months) stent thrombosis occurs predominantly after drug-eluting stent implantation in large native coronary vessel stenting. Methods To prove...... or refute this hypothesis, we set up an 11-center 4-country prospective trial of 2260 consecutive patients treated with >= 3.0-mm stents only, randomized to receive Cypher (Johnson & Johnson, Miami Lakes, FL), Vision (Abbott Vascular, Abbott Laboratories, IL), or Xience stents (Abbott Vascular). Only...... to cobalt-chromium bare-metal stents in this relevant, low-risk group of everyday patients. In addition, a comparison with similar BASKET patients will allow to estimate the impact of 12-versus 6-month dual antiplatelet therapy on these outcomes Udgivelsesdato: 2008/4...

  10. Long-term mortality of coronary artery bypass grafting and bare-metal stenting.

    Science.gov (United States)

    Wu, Chuntao; Zhao, Songyang; Wechsler, Andrew S; Lahey, Stephen; Walford, Gary; Culliford, Alfred T; Gold, Jeffrey P; Smith, Craig R; Holmes, David R; King, Spencer B; Higgins, Robert S D; Jordan, Desmond; Hannan, Edward L

    2011-12-01

    There is little information on relative survival with follow-up longer than 5 years in patients undergoing coronary artery bypass grafting (CABG) and patients undergoing percutaneous coronary intervention (PCI) with stenting. This study tested the hypothesis that CABG is associated with a lower risk of long-term (8-year) mortality than is stenting with bare-metal stents for multivessel coronary disease. We identified 18,359 patients with multivessel disease who underwent isolated CABG and 13,377 patients who received bare-metal stenting in 1999 to 2000 in New York and followed their vital status through 2007 using the National Death Index (NDI). We matched CABG and stent patients on the number of diseased coronary vessels, proximal left anterior descending (LAD) artery disease, and propensity of undergoing CABG based on numerous patient characteristics and compared survival after the 2 procedures. In the 7,235 pairs of matched patients, the overall 8-year survival rates were 78.0% for CABG and 71.2% for stenting (hazard ratio [HR], 0.68; 95% confidence interval [CI], 0.64 to 0.74; p grafting is associated with a lower risk of death than is stenting with bare metal stents for multivessel coronary disease. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Successful stent-in-stent insertion of an expandable metallic stent covered with polyuretane placed to obliterate a large bronchial fistula after chemoradiotherapy for inoperable lung cancer

    International Nuclear Information System (INIS)

    Minami, Hiroya; Tsubota, Noriaki; Miyamoto, Yoshifumi; Yoshimura, Masahiro; Obayashi, Kayoko; Takada, Yoshiki

    1999-01-01

    Bronchial fistulas in cases of inoperable lung cancer caused by radiochemotherapy are quite refractory and generally cannot be surgically closed. A 45-year-old man with squamous cell carcinoma in the right lung underwent two courses of induction chemotherapy (135 mg CDDP, 5 mg VDS, 13.5 mg MMC) and radiation therapy (2 Gy x 22 times) for invasion of the right main bronchus, the pulmonary artery and superior vena cava. Just before the end of the second course, the empyem second to the bronchial fistula caused by tumor necrosis developed in the right upper bronchus, and fenestration was performed. After the operation, his condition improved remarkably, however the fistula enlarged into the right main bronchus and the purulent discharge flowed into the left lung. An expandable metallic stent (EMS) covered with polyuretane was inserted in the trachea and the left main bronchus to break aspiration pneumonia. As the covered EMS was too unstable to be fixed, a bare EMS was inserted in a stent-in-stent fashion. After the procedure he was followed at the O.P.D. and lived a relatively comfortable life for 9 months until his death due to tumor. We inserted the covered EMS in a stent-in-stent fashion to successfully obliterate a large bronchial fistula. (author)

  12. Self-Expandable Metal Stents for Colorectal Cancer: From Guidelines to Clinical Practice

    Directory of Open Access Journals (Sweden)

    Maria Pia Costa Santos

    2016-11-01

    Conclusions: In this study, stent placement was an effective procedure in obstructive colorectal cancer. It was mainly used as a bridge to elective surgery. However, a significant rate of silent perforation was observed, which may compromise the oncological outcome of these potentially curable patients. Prospective real life studies are warranted for a better definition of actual recommendations.

  13. Loss of Renal Function After Retrograde Ureteral Placement of an Allium Stent for Severe Ureteral Stricture

    OpenAIRE

    Salciccia, Stefano; Sciarra, Alessandro; Polese, Milena; Giorgio, Alpi; Maggi, Martina; Gentilucci, Alessandro; Ciccariello, Mauro; D'Eramo, Giuseppe; Shahabadi, Houssain; Lai, Silvia; Ricciuti, Gian Piero

    2018-01-01

    Abstract Background: Ureteral strictures are a recurrent chronic condition that leads to severe side effects and poor quality of life. Management of ureteral stricture is a great challenge for urologists and no specific guidelines exist. Retrograde Allium® ureteral stent (AUS) is a newly developed ureteral stent to treat either bulbar urethral or ureteral stenosis. Case Presentation: We describe a case of a 74-year-old Caucasian adult male presenting with a severe ureteral stricture secondary...

  14. Predictive factors for pancreatitis and cholecystitis in endoscopic covered metal stenting for distal malignant biliary obstruction.

    Science.gov (United States)

    Shimizu, Shuya; Naitoh, Itaru; Nakazawa, Takahiro; Hayashi, Kazuki; Miyabe, Katsuyuki; Kondo, Hiromu; Yoshida, Michihiro; Yamashita, Hiroaki; Umemura, Shuichiro; Hori, Yasuki; Ohara, Hirotaka; Joh, Takashi

    2013-01-01

    Pancreatitis and cholecystitis are major complications after self-expandable metal stent (SEMS) placement in distal malignant biliary obstruction. We aimed to clarify predictive factors for pancreatitis and cholecystitis after covered SEMS placement. We retrospectively reviewed 74 consecutive patients with distal malignant biliary obstruction who underwent initial endoscopic drainage using covered SEMS. Predictive factors for pancreatitis and cholecystitis were evaluated in the 74 patients described above and in 66 patients who had not undergone cholecystectomy. The incidences of pancreatitis and cholecystitis were 10.8% (8/74) and 6.1% (4/66), respectively. Univariate analysis revealed that non-pancreatic cancer (P = 0.018) and contrast injection into the pancreatic duct (P = 0.030) were significant predictive factors for pancreatitis. Multivariate analysis revealed that non-pancreatic cancer (odds ratio [OR], 4.21; 95% confidence interval [CI], 1.63-14.18; P = 0.007) and contrast injection into the pancreatic duct (OR, 3.34; 95% CI, 1.33-9.60; P = 0.016) were significant independent predictive factors for pancreatitis. On the other hand, univariate and multivariate analyses revealed that tumor involvement to the orifice of the cystic duct (OCD) was a significant independent predictive factor for cholecystitis (OR, 5.85; 95% CI, 1.91-27.74; P = 0.005). Non-pancreatic cancer and contrast injection into the pancreatic duct were predictive factors for pancreatitis, and tumor involvement to the OCD was a positive predictive factor for cholecystitis after endoscopic covered SEMS placement for distal malignant biliary obstruction. © 2012 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  15. A pooled analysis of data comparing sirolimus-eluting stents with bare-metal stents

    NARCIS (Netherlands)

    C.M. Spaulding (Christian); J. Daemen (Joost); H. Boersma (Eric); D.E. Cutlip (Donald); P.W.J.C. Serruys (Patrick)

    2007-01-01

    textabstractBACKGROUND: Although randomized studies have shown a beneficial effect of drug-eluting stents in reducing the risk of repeated revascularization, these trials were underpowered to compare rates of death and myocardial infarction. The long-term safety of drug-eluting stents has been

  16. The effectiveness of ureteric metal stents in malignant ureteric obstructions: A systematic review

    OpenAIRE

    Kallidonis, Panagiotis; Kotsiris, Dimitrios; Sanguedolce, Francesco; Ntasiotis, Panteleimon; Liatsikos, Evangelos; Papatsoris, Athanasios

    2017-01-01

    Objective: To review the literature on the effectiveness, safety and long-term patency of ureteric metal mesh stents (MSs), as a variety of MSs have been used for managing malignant ureteric obstruction over the last three decades. Materials and methods: A systematic review using the search string; Ureterâ AND (stent OR endoprosthesis) AND metalâ was conducted on PubMed, Scopus, Web of science and Cochrane Library online databases in May 2016. Prospective, retrospective, and comparative studi...

  17. Ferromagnetic Bare Metal Stent for Endothelial Cell Capture and Retention.

    Science.gov (United States)

    Uthamaraj, Susheil; Tefft, Brandon J; Hlinomaz, Ota; Sandhu, Gurpreet S; Dragomir-Daescu, Dan

    2015-09-18

    Rapid endothelialization of cardiovascular stents is needed to reduce stent thrombosis and to avoid anti-platelet therapy which can reduce bleeding risk. The feasibility of using magnetic forces to capture and retain endothelial outgrowth cells (EOC) labeled with super paramagnetic iron oxide nanoparticles (SPION) has been shown previously. But this technique requires the development of a mechanically functional stent from a magnetic and biocompatible material followed by in-vitro and in-vivo testing to prove rapid endothelialization. We developed a weakly ferromagnetic stent from 2205 duplex stainless steel using computer aided design (CAD) and its design was further refined using finite element analysis (FEA). The final design of the stent exhibited a principal strain below the fracture limit of the material during mechanical crimping and expansion. One hundred stents were manufactured and a subset of them was used for mechanical testing, retained magnetic field measurements, in-vitro cell capture studies, and in-vivo implantation studies. Ten stents were tested for deployment to verify if they sustained crimping and expansion cycle without failure. Another 10 stents were magnetized using a strong neodymium magnet and their retained magnetic field was measured. The stents showed that the retained magnetism was sufficient to capture SPION-labeled EOC in our in-vitro studies. SPION-labeled EOC capture and retention was verified in large animal models by implanting 1 magnetized stent and 1 non-magnetized control stent in each of 4 pigs. The stented arteries were explanted after 7 days and analyzed histologically. The weakly magnetic stents developed in this study were capable of attracting and retaining SPION-labeled endothelial cells which can promote rapid healing.

  18. Sirolimus-eluting stents suppress neointimal formation irrespective of metallic allergy.

    Science.gov (United States)

    Nakazawa, Gaku; Tanabe, Kengo; Aoki, Jiro; Onuma, Yoshinobu; Higashikuni, Yasutomi; Yamamoto, Hirosada; Ohtsuki, Shuji; Yachi, Sen; Yagishita, Atsuhiko; Nakajima, Hiroyoshi; Hara, Kazuhiro

    2008-06-01

    Metallic allergy is associated with restenosis following bare metal stent implantation, but the impact of metallic allergy on the outcome after implantation of drug-eluting stents (DES) has not been investigated. The present study group consisted of 88 consecutive patients (109 lesions) who underwent percutaneous coronary intervention with sirolimus-eluting stents (SES). Follow-up angiography was obtained at 8 months in all patients. At that time, the patients underwent epicutaneous patch tests for nickel, chromate, molybdenum, manganese, and titanium, which were evaluated after 48 h of contact. The patch test was positive in 14 patients (16%) (5 for manganese, 3 for nickel, 1 for chromate, 1 for Nickel and manganese, and 4 for manganese and chromate). The binary restenosis rate in the patients with a positive patch test was similar to those with negative patch test (6.3% vs 6.5%, p=0.98). Serial quantitative coronary angiography analyses identified no significant differences in late lumen loss of in-stent segments between patients with positive patch test and those with negative patch test (0.19+/-0.49 mm vs 0.12+/-0.48 mm, p=0.55). SES prevent restenosis irrespective of metallic allergy. The classic relationship between metallic allergy and in-stent restenosis, seen with bare metal stents, does not appear to arise with DES, possibly because of the immunosuppressive effect of sirolimus.

  19. Stent-Graft Placement with Early Debridement and Antibiotic Treatment for Femoral Pseudoaneurysms in Intravenous Drug Addicts

    International Nuclear Information System (INIS)

    Fu, Qining; Meng, Xiyun; Li, Fenghe; Wang, Xuehu; Cheng, Jun; Huang, Wen; Ren, Wei; Zhao, Yu

    2015-01-01

    PurposeExplore the application of endovascular covered stent-graft (SG) placement in femoral pseudoaneurysms in intravenous drug addicts.Materials and MethodsWe evaluated a consecutive series of pseudoaneurysm in intravenous drug addicts treated with SGs from August 2010 to December 2013.Results15 patients with 16 arterial pseudoaneurysms were enrolled in this study. All were males with a mean age of 36.9 years. Hemorrhage was the most common reason (93.8 %) for seeking medical care, and 3 of these patients were in hemorrhagic shock at admission. All patients received broad-spectrum antibiotics, and debridement and drainage were implemented after SG placement. 7 of the 13 cases which had microbiologic results showed mixed infections, while gram-negative bacteria were the major pathogens. Except for 2 patients, who were lost to follow-up, two new pseudoaneurysms formed due to delayed debridement, and one stent thrombosis occurred, none of the remaining cases had SG infection or developed claudication.ConclusionsSG placement controls massive hemorrhage rapidly, gives enough time for subsequent treatment for pseudoaneurysms due to intravenous drug abuse, and reduces the incidence of postoperative claudication. With appropriate broad-spectrum antibiotics and early debridement, the incidence of SG infection is relatively low. It is an effective alternative especially as temporary bridge measure for critical patients. However, the high cost, uncertain long-term prospects, high demand for medical adherence, and the risk of using the conduits for re-puncture call for a cautious selection of patients. More evidence is required for the application of this treatment

  20. Stent-Graft Placement with Early Debridement and Antibiotic Treatment for Femoral Pseudoaneurysms in Intravenous Drug Addicts

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Qining, E-mail: cqmufqn@163.com; Meng, Xiyun, E-mail: 383274177@qq.com; Li, Fenghe, E-mail: lfh-cqmu@gmail.com; Wang, Xuehu, E-mail: 184037696@qq.co; Cheng, Jun, E-mail: cqdcj@163.com; Huang, Wen, E-mail: dhuangwen@hotmail.com; Ren, Wei, E-mail: renwei9771@yahoo.com.cn; Zhao, Yu, E-mail: zhaoyu-cqmu@126.com [The First Affiliated Hospital of Chongqing Medical University, Department of Vascular Surgery (China)

    2015-06-15

    PurposeExplore the application of endovascular covered stent-graft (SG) placement in femoral pseudoaneurysms in intravenous drug addicts.Materials and MethodsWe evaluated a consecutive series of pseudoaneurysm in intravenous drug addicts treated with SGs from August 2010 to December 2013.Results15 patients with 16 arterial pseudoaneurysms were enrolled in this study. All were males with a mean age of 36.9 years. Hemorrhage was the most common reason (93.8 %) for seeking medical care, and 3 of these patients were in hemorrhagic shock at admission. All patients received broad-spectrum antibiotics, and debridement and drainage were implemented after SG placement. 7 of the 13 cases which had microbiologic results showed mixed infections, while gram-negative bacteria were the major pathogens. Except for 2 patients, who were lost to follow-up, two new pseudoaneurysms formed due to delayed debridement, and one stent thrombosis occurred, none of the remaining cases had SG infection or developed claudication.ConclusionsSG placement controls massive hemorrhage rapidly, gives enough time for subsequent treatment for pseudoaneurysms due to intravenous drug abuse, and reduces the incidence of postoperative claudication. With appropriate broad-spectrum antibiotics and early debridement, the incidence of SG infection is relatively low. It is an effective alternative especially as temporary bridge measure for critical patients. However, the high cost, uncertain long-term prospects, high demand for medical adherence, and the risk of using the conduits for re-puncture call for a cautious selection of patients. More evidence is required for the application of this treatment.

  1. Prior radiation and chemotherapy increase the risk of life-threatening complications after insertion of metallic stents for esophagogastric malignancy.

    Science.gov (United States)

    Kinsman, K J; DeGregorio, B T; Katon, R M; Morrison, K; Saxon, R R; Keller, F S; Rosch, J

    1996-03-01

    Self-expanding metallic stents (SEMS) are effective in relieving the symptoms of obstructing esophagogastric malignancy. While complications with SEMS have been described, factors influencing such occurrence have not been defined. Self-expanding Gianturco-Rosch Z-stents were placed successfully in 59 patients with obstructing esophagogastric malignancies. Early procedure-related complications occurred in 6 patients (10%) and were usually minor. Twenty-three late complications occurred in 22 patients (37.5%). Life-threatening complications occurred in 9 patients (15%), including gastrointestinal bleeding (7), perforation (1), and tracheoesophageal fistula (1) and contributed to all five deaths. Eight of 22 patients with prior radiation and/or chemotherapy (36.4%) had life-threatening complications compared to 1 of 37 (2.5%) without prior therapy (p = 0.001). Stent-related mortality occurred in 5 of 22 (23%) patients with prior therapy compared to none of the 37 without prior therapy (p = 0.005). Multivariate analysis confirmed the association between prior radiation and/or chemotherapy and life-threatening complications (p = 0.012; odds ratio, 32.63) and also an association with female gender (p = 0.032; odds ratio, 13.9). There was no association with tumor location or length, histologic type, age, prestent dysphagia grade, or previous surgical resection. Patients with prior radiation and/or chemotherapy have an increased risk of severe complications following placement of SEMS.

  2. Microvascular Coronary Flow Comparison in Acute Myocardial Infarction Angioplasty treated with a mesh covered stent (MGUARD Stent) versus Bare Metal Stent

    Energy Technology Data Exchange (ETDEWEB)

    Lindefjeld, Dante S., E-mail: dslindef@puc.cl [Hospital Clínico, Pontificia Universidad Católica de Chile (Chile); Hospital Dr. Sótero del Río, Santiago-Chile (Chile); Guarda, Eduardo [Hospital Clínico, Pontificia Universidad Católica de Chile (Chile); Méndez, Manuel [Hospital Clínico, Pontificia Universidad Católica de Chile (Chile); Hospital Dr. Sótero del Río, Santiago-Chile (Chile); Martínez, Alejandro [Hospital Clínico, Pontificia Universidad Católica de Chile (Chile); Pérez, Osvaldo [Hospital Clínico, Pontificia Universidad Católica de Chile (Chile); Hospital Dr. Sótero del Río, Santiago-Chile (Chile); Fajuri, Alejandro; Marchant, Eugenio [Hospital Clínico, Pontificia Universidad Católica de Chile (Chile); Aninat, Mauricio; Torres, Humberto [Hospital Dr. Gustavo Fricke, Viña del Mar-Chile (Chile); Dussaillant, Gastón [Hospital Clínico Universidad de Chile, Santiago-Chile (Chile)

    2013-01-15

    Background: Distal embolization of thrombus/platelet aggregates decreases myocardial reperfusion during primary percutaneous coronary intervention (PCI), and is associated with worse immediate and long-term prognosis of patients with ST-elevation myocardial infarction (STEMI). Objective: Assess the efficacy of a mesh covered stent (MGuard™ stent, MGS) in preventing distal embolization and microvascular reperfusion impairment during primary PCI, compared with a bare metal stent (BMS). Methods: Forty patients with STEMI referred for primary PCI were randomized for stenting the culprit lesion with the MGS (n = 20) or a BMS (n = 20). Blinded experts performed off-line measurements of angiographic epicardial and microvascular reperfusion criteria: TIMI flow grade, myocardial blush, corrected TIMI frame count (cTFC). Results: At baseline clinical, angiographic and procedural variables were not different between groups. Post PCI TIMI flow grade was similar in both groups. We observed better myocardial Blush grade in group MGS compared to BMS (median value 3.0 vs 2.5, 2p = 0.006) and cTFC (mean cTFC: MGS 19.65 ± 4.07 vs BMS 27.35 ± 7.15, 2p < 0.001, cTFC mean difference MGS-BMS: 7.7, CI 95%: 3.94 to 11.46). MGS stent group had a higher percentage of successful angioplasty (cTFC ≤ 23: MGS 85% vs BMS 30%, 2p < 0.001). We had two cases of acute stent thrombosis (one for each group) at 30 days follow up, but no clinical events at 6 months follow up. Conclusions: In this exploratory study, MGS significantly improved microvascular reperfusion criteria compared with a BMS in primary PCI. However its safety and impact on clinical outcomes should be verified in larger randomized clinical trials.

  3. Thoracic aortic stent-graft placement combined with left subclavian artery 'chimney operation': therapeutic analysis of 15 cases with insufficient proximal anchor area

    International Nuclear Information System (INIS)

    Liu Jiayi; Huang Lianjun; Fan Zhanming; Zhang Zhaoqi

    2012-01-01

    Objective: To discuss the strategies for the management of insufficient proximal anchoring area during the performance of transluminal stent-graft placement (TSGP), and to evaluate the feasibility of intentional coverage of the left subclavian artery (LSA) together with left subclavian artery stent-graft placement by using 'chimney operation' technique. Methods: A total of 15 patients with thoracic aortic diseases complicated by insufficient proximal anchoring area, who were encountered in authors' hospital during the period from Dec. 2009 to April 2011, were enrolled in this study. The clinical data were retrospectively analyzed. The thoracic aortic diseases included aortic dissection (n=6), aortic pseudoaneurysm (n=1), aortic aneurysm (n=4) and penetrating ulcer (n=4). Of the 15 patients, the distance between the lesion and LSA anchoring site 15 mm in 2. TSGP was carried out. The ostium of LSA was intentionally and completely covered by thoracic aortic stent-graft and left subclavian artery stent-graft placement was subsequently performed. The patients were kept under observation for symptoms of cerebral and upper limb ischemia. The postoperative complications such as endoleak and the patency of LSA were assessed with angiography. Results: Thoracic aortic stent-graft placement was successfully carried out in all 15 patients. In addition, one 'chimney' stent was properly implanted in LSA in each patient. After the procedure, no complications of nervous system or severe ischemia of upper extremity occurred. Follow-up examinations performed between 5 days to 3 months after the treatment revealed that the aortic stent-graft remained in stable condition and no type Ⅰ endoleak occurred, meanwhile the blood flow in 'chimney' stent was unobstructed. Conclusion: Intentional LSA coverage with 'chimney operation' can expand the applicability of TSGP with high tolerability. It is especially useful for patients with left vertebral artery blood supply dominance or with

  4. Metallic stent with high axial force as a risk factor for cholecystitis in distal malignant biliary obstruction.

    Science.gov (United States)

    Nakai, Yousuke; Isayama, Hiroyuki; Kawakubo, Kazumichi; Kogure, Hirofumi; Hamada, Tsuyoshi; Togawa, Osamu; Ito, Yukiko; Matsubara, Saburo; Arizumi, Toshihiko; Yagioka, Hiroshi; Takahara, Naminatsu; Uchino, Rie; Mizuno, Suguru; Miyabayashi, Koji; Yamamoto, Keisuke; Sasaki, Takashi; Yamamoto, Natsuyo; Hirano, Kenji; Tada, Minoru; Koike, Kazuhiko

    2014-01-01

    Tumor involvement to the orifice of cystic duct (OCD) is a risk factor for cholecystitis after self-expandable metallic stent (SEMS) placement, but its prevention is still difficult. We conducted this multicenter analysis to clarify a type of SEMS or a method to place SEMS which would decrease the incidence of cholecystitis after SEMS placement. The incidence of cholecystitis was studied in consecutive patients receiving SEMS for distal malignant biliary obstruction in five tertiary care centers. Multiple logistic regression analysis was performed to evaluate risk factors for cholecystitis. A total of 376 patients who received SEMS placement for distal malignant biliary obstruction were analyzed. Tumor involvement to OCD was diagnosed in 25.3%. Overall incidence of cholecystitis was 6.9%. Cholecystitis was observed in 8.0% of 300 patients with covered SEMS, 16.8% of 95 patients with tumor involvement to OCD, 10.8% of 234 patients with SEMS of high axial force (AF), and 12.0% of 158 patients with SEMS length ≤ 60 mm. In the multivariate analysis, tumor involvement to OCD (odds ratio [OR] 5.40, P cholecystitis in SEMS with high and low AF was 25.0% and 5.0%, respectively. This study with an expanded cohort reconfirmed tumor involvement to OCD as a risk factor for cholecystitis after SEMS placement. SEMS with low AF might decrease cholecystitis. © 2014 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  5. Endovascular Stent Graft Placement in the Treatment of Ruptured Tuberculous Pseudoaneurysm of the Descending Thoracic Aorta: Case Report and Review of the Literature

    International Nuclear Information System (INIS)

    Dogan, Sozen; Memis, Ahmet; Kale, Arzum; Buket, Suat

    2009-01-01

    We report a successful repair of a ruptured tuberculous pseudoaneurysm of the descending thoracic aorta by endovascular stent graft placement. This procedure is starting to be accepted as an alternative method to surgery, and we review similar cases in the literature.

  6. Rational imaging concepts in the follow-up of stent-graft placements for aortic aneurysm and aortic dissection

    International Nuclear Information System (INIS)

    Hansmann, H.J.; Kampschulte, A.; Schumacher, H.; Noeldge, G.; Richter, G.M.

    2001-01-01

    Goal. To identify essential and relevant diagnostic algorithms in the follow-up of stent-grafts placed for aortic dissections and aneurysms based on our 7 years experience including the use of more than 10 different devices. Material and Methods. Evaluation of conventional biplane imaging, angiography, sonography, CT and MR in the efficacy of demonstrating endoleaks, sac shrinkage, changes of stent-graft integrity and, with special reference to MR-compatibility of various stent-graft devices. Results. Endoleaks are found in 20-30% of patients after endovascular exclusion of abdominal aortic aneurysms. However, this rate neither necessarily reflects the clinical course nor the onset and course of sac shrinkage. Physical long-term integrity of the devices is seen best on conventional bi-plane radiographs. Sonography is helpful only in selected patients (non-obese, good compliance) otherwise not providing information precisely enough for sac control. As gold standard both CT (CTA) and MR (MRA) are equally effective in the follow-up of endovascular stent-grafts, allowing 3D control of sac geometry in aneurysmal disease or hemodynamic changes in stent-grafts for aortic dissection. MRI is considered to be more effective in the detection of small endoleaks. Angiography is inferior to CT and MRI in the diagnosis of endoleaks and thus is required only for intervention planning in patients with suspected endoleaks. Two of 8 evaluated stent-graft devices proved to be prohibitive for MRI because of their severe artifacts productions (Life-path, Zenith) as a result of their thick metallic meshwork. Conclusion. CT including CTA with 2D and 3D reformatting is the method of choice for the follow up of stent-graft treatment of aortic disease. Depending on availability, MRI may be used alternatively. In young patients and for those with contraindications to iodinated contrast media MRI is a perfectly equivalent alternative. Especially in patients with known contraindications to

  7. The effect of sirolimus-eluting stent implantation on re-endothelialization: a comparative study with bare-metal stent implantation in rabbits

    International Nuclear Information System (INIS)

    Zhang Lin; ZZhang Ruiyan; Zhu Zhengbin; Du Run; Shen Weifeng

    2009-01-01

    Objective: To evaluate the effect of sirolimus-eluting stent implantation on the reendothelialization of abdominal aorta in rabbits, and to compare it with that of bare-metal stent implantation. Methods: Twenty-four New Zealand male rabbits were randomly and equally divided into two groups after hyperlipemia feeding. Sirolimus-eluting stent, Firebird, or bare-metal stent, Mustang, was implanted in the abdominal aorta in two groups. Every three experimental rabbits from both groups were sacrificed each time at 3, 7, 14 and 28 days after the procedure, and the specimens of aorta were harvested and processed for observing the vascular endothelia with scanning electron microscopy, and the degree of re-endothelialization was analyzed by computed imaging analysis technique. Results: Three days after the procedure, in both groups neogenetic endothelia could be hardly seen in the treated aorta although inflammatory reaction was rather obvious. At the time of 7, 14 and 28 days after the operation, the covering rate of re-endothelialization in sirolimus-eluting stent group was significantly lower than that in bare-metal stent group (15% ±8% vs 53% ± 9%, 49% ±16% vs 83% ± 4% and 73% ± 3% vs 93% ± 4% respectively, P < 0.05). Conclusion: Compared with bare-metal stent, sirolimus-eluting stent will markedly delay the re-endothelialization of the implanted vessels. (authors)

  8. The use of self expandable metallic stent in the management of malignant biliary obstruction

    International Nuclear Information System (INIS)

    Han, Joon Koo; Choi, Byung Ihn; Chung, Jin Wook; Park, Jae Hyung; Han, Gi Seok; Han, Man Chung

    1993-01-01

    Self expandable metallic stent is a good alternative of percutaneous transhepatic biliary drainage because it can eliminate numerous problems caused by external drainage catheter, such as tube dislodgement, bile leakage and psychotic problems. Authors analyzed initial results of self expandable metallic stents used in the patient with malignant biliary obstruction to evaluate the efficacy of the procedure and to find the technical problems in the procedure. Self expandable metallic stents were inserted in 14 patients: three with recurrent stomach cancer: three with gallbladder cancer: seven with Klaskin tumor: one with common duct cancer. Gianturco type stent was used in 9 cases ans Wallstent was used in 2 cases. In remaining three case, both Z-stent and Wallstent were used in the same patient. The average period of follow up was 104 days (4-409 days). In 13 cases, the patency of the bile duct was restored by the stent (technical success: 92.9%). Occlusions of the stent were found in two cases, after two and 13 months, respectively. Causes of failure and stent occlusion were associated duodenal obstruction, tumor overgrowth and shortening of Wallstent. In remaining 11 patients, one patient was lost to follow up an 10 patients did not show recurrent jaundice until death or last follow up. There was no major complication related to the procedure. The insertion of self expandable metallic stent is a safe procedure and can eliminate major disadvantages of PTBD. Overstenting, overlapping and evaluation of associated GI tract obstruction is crucial for obtaining technical success and long-term patency

  9. Long-term safety and outcome of a temporary self-expanding metallic stent for achalasia: a prospective study with a 13-year single-center experience

    International Nuclear Information System (INIS)

    Zhao, Jun-Gong; Li, Yong-Dong; Li, Ming-Hua; Shang, Ke-Zhong; Cheng, Ying-Sheng; Chen, Ni-Wei; Chen, Wei-Xiong

    2009-01-01

    To prospectively evaluate the long-term clinical safety and efficacy of a newly designed self-expanding metallic stent (SEMS) in the treatment of patients with achalasia. Seventy-five patients with achalasia were treated with a temporary SEMS with a 30-mm diameter. The SEMSs were placed under fluoroscopic guidance and removed by gastroscopy 4-5 days after stent placement. Follow-up data focused on dysphagia score, technique and clinical success, clinical remissions and failures, and complications and was performed at 6 months, 1 year, and within 3 to 5 years, 5 to 8 years, 8 to 10 years, and >10 years postoperatively. Stent placement was technically successful in all patients. Complications included stent migration (n=4, 5.33%), chest pain (n=28, 38.7%), reflux (n=15, 20%), and bleeding (n=9, 12%). No perforation or 30-day mortality occurred. Clinical success was achieved in all patients 1 month after stent removal. The overall remission rates at 6 months, 1, 1-3, 3-5, 5-8, 8-10, and >10 year follow-up periods were 100%, 96%, 93.9%, 90.9%, 100%, 100%, and 83.3%, respectively. Stent treatment failed in six patients, and the overall remission rate in our series was 92%. The median and mean primary patencies were 2.8 ± 0.28 years (95% CI: 2.25-3.35) and 4.28 ± 0.40 years (95% CI: 3.51-5.05), respectively. The use of temporary SEMSs with 30-mm diameter proved to be a safe and effective approach for managing achalasia with a long-term satisfactory clinical remission rate. (orig.)

  10. Effective treatment of benign biliary strictures with a removable, fully covered, self-expandable metal stent: A prospective, multicenter European study.

    Science.gov (United States)

    Schmidt, Arthur; Pickartz, Tilman; Lerch, Markus M; Fanelli, Fabrizio; Fiocca, Fausto; Lucatelli, Pierleone; Cereatti, Fabrizio; Hoffmeister, Albrecht; van Steenbergen, Werner; Kraft, Matthias; Meier, Benjamin; Caca, Karel

    2017-04-01

    Temporary placement of removable, fully covered, self-expandable metal stents (fcSEMS) for treatment of benign biliary strictures (BBS) has been reported to be effective. However, the optimal extraction time point remains unclear and stent migration has been a major concern. The objective of this study was to evaluate the efficacy and safety of this treatment modality using an fcSEMS with a special antimigration design and prolonged stent indwell time. We performed a prospective, single-arm study at six tertiary care centers in Europe. Patients with BBS underwent endoscopic or percutaneous implantation of an fcSEMS (GORE® VIABIL® Biliary Endoprosthesis, W.L. Gore & Associates, Flagstaff, AZ, USA). The devices were scheduled to be removed nine months later, and patients were to return for follow-up for an additional 15 months. Forty-three patients were enrolled in the study. Stricture etiology was chronic pancreatitis in the majority of patients (57.5%). All fcSEMS were placed successfully, either endoscopically (76.7%) or percutaneously (23.3%). Stent migration was observed in two patients (5.2%). Primary patency of the SEMS prior to removal was 73.0%. All attempted stent removals were successful. At removal, stricture was resolved or significantly improved without need for further therapy in 78.9% of patients. Stricture recurrence during a follow-up of two years post-implant was observed in two patients. Temporary placement of the fcSEMS is a feasible, safe and effective treatment for BBS. The design of the device used in this study accounts for very low migration rates and facilitates easy stent retrieval, even after it has been in place for up to 11 months.

  11. Anesthetic management of a large mediastinal mass for tracheal stent placement

    Directory of Open Access Journals (Sweden)

    Suman Rajagopalan

    2016-04-01

    Full Text Available ABSTRACT The anesthetic management of patients with large mediastinal masses can be complicated due to the pressure effects of the mass on the airway or major vessels. We present the successful anesthetic management of a 64-year-old female with a large mediastinal mass that encroached on the great vessels and compressed the trachea. A tracheal stent was placed to relieve the tracheal compression under general anesthesia. Spontaneous ventilation was maintained during the perioperative period with the use of a classic laryngeal mask airway. We discuss the utility of laryngeal mask airway for anesthetic management of tracheal stenting in patients with mediastinal masses.

  12. Evaluation of the Effects of Temporary Covered Nitinol Stent Placement in the Prostatic Urethra: Short-Term Study in the Canine Model

    International Nuclear Information System (INIS)

    Crisostomo, Veronica; Song, Ho Young; Maynar, Manuel; Sun, Fei; Soria, Federico; Lima, Juan Rafael; Yoon, Chang Jin; Uson-Gargallo, Jesus

    2007-01-01

    Purpose. To evaluate the effect of temporary stent placement on the canine prostatic urethra. Methods. Retrievable PTFE-covered nitinol stents were placed in the prostatic urethras of 8 beagle dogs under fluoroscopic guidance. Retrograde urethrography was obtained before and after stenting. Retrograde urethrography and endoscopy were performed 1 and 2 months after deployment. The endoscopic degree of hyperplasia was rated on a scale of 0 to 4 (0 absence, 4 = occlusion). On day 60, stents were removed and urethrography was performed immediately before euthanasia. Pathologic analysis was performed to determine the degree of glandular atrophy, periurethral fibrosis, and urethral dilation. Results. Stent deployment was technically successful in 7 animals, and failed in 1 dog due to a narrow urethral lumen. Complete migration was seen in 2 animals at 1 month, and an additional stent was deployed. On day 30, endoscopy showed slight hyperplasia (grade 1) in 3 animals. On day 60, moderate hyperplasia (grade 2) was evidenced in 4 cases. No impairment of urinary flow was seen during follow-up. Retrieval was technically easy to perform, and was successful in all dogs. The major histologic findings were chronic inflammatory cell infiltrates; prostate glandular atrophy, with a mean value of 1.86 (SD 0.90); periurethral fibrosis, with a mean ratio of 29.37 (SD 10.41); and dilatation of the prostatic urethra, with a mean ratio of 6.75 (SD 3.22). Conclusion. Temporary prostatic stent placement in dogs is safe and feasible, causing marked enlargement of the prostatic urethral lumen. Retrievable covered stents may therefore be an option for bladder outlet obstruction management in men

  13. Endoscopic ultrasound-guided gallbladder drainage for acute cholecystitis: Long-term outcomes after removal of a self-expandable metal stent.

    Science.gov (United States)

    Kamata, Ken; Takenaka, Mamoru; Kitano, Masayuki; Omoto, Shunsuke; Miyata, Takeshi; Minaga, Kosuke; Yamao, Kentaro; Imai, Hajime; Sakurai, Toshiharu; Watanabe, Tomohiro; Nishida, Naoshi; Kudo, Masatoshi

    2017-01-28

    To assess the long-term outcomes of this procedure after removal of self-expandable metal stent (SEMS). The efficacy and safety of endoscopic ultrasound-guided gallbladder drainage (EUS-GBD) with SEMS were also assessed. Between January 2010 and April 2015, 12 patients with acute calculous cholecystitis, who were deemed unsuitable for cholecystectomy, underwent EUS-GBD with a SEMS. EUS-GBD was performed under the guidance of EUS and fluoroscopy, by puncturing the gallbladder with a needle, inserting a guidewire, dilating the puncture hole, and placing a SEMS. The SEMS was removed and/or replaced with a 7-Fr plastic pigtail stent after cholecystitis improved. The technical and clinical success rates, adverse event rate, and recurrence rate were all measured. The rates of technical success, clinical success, and adverse events were 100%, 100%, and 0%, respectively. After cholecystitis improved, the SEMS was removed without replacement in eight patients, whereas it was replaced with a 7-Fr pigtail stent in four patients. Recurrence was seen in one patient (8.3%) who did not receive a replacement pigtail stent. The median follow-up period after EUS-GBD was 304 d (78-1492). EUS-GBD with a SEMS is a possible alternative treatment for acute cholecystitis. Long-term outcomes after removal of the SEMS were excellent. Removal of the SEMS at 4-wk after SEMS placement and improvement of symptoms might avoid migration of the stent and recurrence of cholecystitis due to food impaction.

  14. IVUS Findings in Late and Very Late Stent Thrombosis. A Comparison Between Bare-metal and Drug-eluting Stents.

    Science.gov (United States)

    Fuentes, Lara; Gómez-Lara, Josep; Salvatella, Neus; Gonzalo, Nieves; Hernández-Hernández, Felipe; Fernández-Nofrerias, Eduard; Sánchez-Recalde, Ángel; Alfonso, Fernando; Romaguera, Rafael; Ferreiro, José Luis; Roura, Gerard; Teruel, Luis; Gracida, Montserrat; Marcano, Ana Lucrecia; Gómez-Hospital, Joan-Antoni; Cequier, Ángel

    2017-09-01

    Stent thrombosis (ST) is a life-threatening complication after stent implantation. Intravascular ultrasound is able to discern most causes of ST. The aim of this study was to compare intravascular ultrasound findings between bare-metal stents (BMS) and drug-eluting stents (DES) in patients with late (31 days to 1 year) or very late ST (> 1 year). Of 250 consecutive patients with late or very late ST in 7 Spanish institutions, 114 patients (45.5% BMS and 54.5% DES) were imaged with intravascular ultrasound. Off-line intravascular ultrasound analysis was performed to assess malapposition, underexpansion, and neoatherosclerosis. The median time from stent implantation to ST was 4.0 years with BMS and 3.4 years with DES (P = .04). Isolated malapposition was similarly observed in both groups (36.5% vs 46.8%; P = .18) but was numerically lower with BMS (26.6% vs 48.0%; P = .07) in patients with very late ST. Isolated underexpansion was similarly observed in both groups (13.5% vs 11.3%; P = .47). Isolated neoatherosclerosis occurred only in patients with very late ST and was more prevalent with BMS (22.9%) than with DES (6.0%); P = .02. At 2.9 years' follow-up, there were 0% and 6.9% cardiac deaths, respectively (P = .06) and recurrent ST occurred in 4.0% and 5.2% of patients, respectively (P = .60). Malapposition was the most common finding in patients with late and very late ST and is more prevalent with DES in very late ST. In contrast, neoatherosclerosis was exclusively observed in patients with very late ST and mainly with BMS. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  15. Mechanical behavior of polymer-based vs. metallic-based bioresorbable stents

    OpenAIRE

    Ang, Hui Ying; Huang, Ying Ying; Lim, Soo Teik; Wong, Philip; Joner, Michael; Foin, Nicolas

    2017-01-01

    Bioresorbable scaffolds (BRS) were developed to overcome the drawbacks of current metallic drug-eluting stents (DES), such as late in-stent restenosis and caging of the vessel permanently. The concept of the BRS is to provide transient support to the vessel during healing before being degraded and resorbed by the body, freeing the vessel and restoring vasomotion. The mechanical properties of the BRS are influenced by the choice of the material and processing methods. Due to insufficient radia...

  16. Gastroduodenal stent placement versus surgical gastrojejunostomy for the palliation of gastric outlet obstructions in patients with unresectable gastric cancer: a propensity score-matched analysis.

    Science.gov (United States)

    Park, Jung-Hoon; Song, Ho-Young; Yun, Sung-Cheol; Yoo, Moon-Won; Ryu, Min-Hee; Kim, Jin Hyoung; Kim, Do Hoon; Lee, Jeong Hoon; Zhou, Wei-Zhong; Yook, Jeong Hwan; Jung, Hwoon-Yong

    2016-08-01

    To compare the outcomes between stent placement and surgical gastrojejunostomy (GJ) for the palliation of gastric outlet obstruction (GOO) in patients with unresectable gastric cancer. A retrospective study was performed in a single university hospital in 224 patients with GOO, and who were treated either by stent placement (n = 124) or surgical GJ (n = 100). The outcomes were assessed with reference to the following variables with the use of propensity-score matching: success rates; complications; dysphagia scores, albumin, and body mass index; survival; symptom-free duration; and hospitalization. We identified a well-balanced cohort of 74 pairs of patients, matched on the basis of propensity score. The dysphagia score 7 days after treatment was significantly better in the stent group (P obstruction symptoms and better nutritional status. • The two methods are equally effective in palliating gastric outlet obstruction symptoms • The stent group showed rapid and efficient palliation of symptoms • Recurrent symptoms were more frequent in the stent group • Surgical gastrojejunostomy provides a longer symptom-free duration and better nutritional status.

  17. Development of prognostic model for predicting survival after retrograde placement of ureteral stent in advanced gastrointestinal cancer patients and its evaluation by decision curve analysis.

    Science.gov (United States)

    Kawano, Shingo; Komai, Yoshinobu; Ishioka, Junichiro; Sakai, Yasuyuki; Fuse, Nozomu; Ito, Masaaki; Kihara, Kazunori; Saito, Norio

    2016-10-01

    The aim of this study was to determine risk factors for survival after retrograde placement of ureteral stents and develop a prognostic model for advanced gastrointestinal tract (GIT: esophagus, stomach, colon and rectum) cancer patients. We examined the clinical records of 122 patients who underwent retrograde placement of a ureteral stent against malignant extrinsic ureteral obstruction. A prediction model for survival after stenting was developed. We compared its clinical usefulness with our previous model based on the results from nephrostomy cases by decision curve analysis. Median follow-up period was 201 days (8-1490) and 97 deaths occurred. The 1-year survival rate in this cohort was 29%. Based on multivariate analysis, primary site of colon origin, absence of retroperitoneal lymph node metastasis and serum albumin >3g/dL were significantly associated with a prolonged survival time. To develop a prognostic model, we divided the patients into 3 risk groups of favorable: 0-1 factors (N.=53), intermediate: 2 risk factors (N.=54), and poor: 3 risk factors (N.=15). There were significant differences in the survival profiles of these 3 risk groups (P<0.0001). Decision curve analyses revealed that the current model has a superior net benefit than our previous model for most of the examined probabilities. We have developed a novel prognostic model for GIT cancer patients who were treated with retrograde placement of a ureteral stent. The current model should help urologists and medical oncologists to predict survival in cases of malignant extrinsic ureteral obstruction.

  18. Current status and future direction of biodegradable metallic and polymeric vascular scaffolds for next-generation stents.

    Science.gov (United States)

    Im, Seung Hyuk; Jung, Youngmee; Kim, Soo Hyun

    2017-09-15

    Because of the increasing incidence of coronary artery disease, the importance of cardiovascular stents has continuously increased as a treatment of this disease. Biodegradable scaffolds fabricated from polymers and metals have emerged as promising materials for vascular stents because of their biodegradability. Although such stent framework materials have shown good clinical efficacy, it is difficult to decide whether polymers or metals are better vascular scaffolds because their properties are different. Therefore, there are still obstacles in the development of biodegradable vascular scaffolds in terms of improving clinical efficacy. This review analyzes the pros and cons of current stent materials with respect to five key factors for next-generation stent and discusses methods of improvement. Furthermore, we discuss biodegradable electronic stents with electrical conductivity, which has been considered unimportant until now, and highlight electrical conductivity as a key factor in the development of next-generation stents. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  19. Management of recurrent bulbar urethral stricture-a 54 patients study with Allium bulbar urethral stent (BUS)

    OpenAIRE

    Culha, Melih; Ozkuvanci, Unsal; Ciftci, Seyfettin; Saribacak, Ali; Ustuner, Murat; Yavuz, Ufuk; Yilmaz, Hasan; Ozkan, Levend

    2014-01-01

    The Allium Bulbar Urethral Stent (BUS) is a fully covered, self-expandable, large caliber metal stent specially designed for the treatment of bulbar urethra strictures. The stent is intended for a long term use for the purpose of opening the occluded urethral passage and to allow spontaneous urination. This study objective was to evaluate the clinical efficacy of temporary placement of the Allium BUS stent. This was a prospective study in 54 men with recurrent benign urethral stricture conduc...

  20. Successful Treatment of Isolated Spontaneous Superior Mesenteric Artery Dissection with Stent Placement

    International Nuclear Information System (INIS)

    Yoon, Young-Won; Choi, Donghoon; Cho, Seung-Yun; Lee, Do Yun

    2003-01-01

    Isolated dissection of superior mesenteric artery is a rare condition and is usually treated surgically. We treated a patient with severe abdominal pain who was angiographically confirmed to have superior mesenteric artery thrombosis associated with isolated spontaneous dissection. He was treated initially by thrombolysis and oral anticoagulation, but recurrent symptoms developed with radiologic evidence of disease progression. We performed superior mesenteric artery stenting and recovery was uneventful

  1. Very late stent thrombosis with second generation drug eluting stents compared to bare metal stents: Network meta-analysis of randomized primary percutaneous coronary intervention trials.

    Science.gov (United States)

    Philip, Femi; Stewart, Susan; Southard, Jeffrey A

    2016-07-01

    The relative safety of drug-eluting stents (DES) and bare-metal stents (BMS) in primary percutaneous coronary intervention (PPCI) in ST elevation myocardial infarction (STEMI) continues to be debated. The long-term clinical outcomes between second generation DES and BMS for primary percutaneous coronary intervention (PCI) using network meta-analysis were compared. Randomized controlled trials comparing stent types (first generation DES, second generation DES, or BMS) were considered for inclusion. A search strategy used Medline, Embase, Cochrane databases, and proceedings of international meetings. Information about study design, inclusion criteria, and sample characteristics were extracted. Network meta-analysis was used to pool direct (comparison of second generation DES to BMS) and indirect evidence (first generation DES with BMS and second generation DES) from the randomized trials. Twelve trials comparing all stents types including 9,673 patients randomly assigned to treatment groups were analyzed. Second generation DES was associated with significantly lower incidence of definite or probable ST (OR 0.59, 95% CI 0.39-0.89), MI (OR 0.59, 95% CI 0.39-0.89), and TVR at 3 years (OR 0.50: 95% CI 0.31-0.81) compared with BMS. In addition, there was a significantly lower incidence of MACE with second generation DES versus BMS (OR 0.54, 95% CI 0.34-0.74) at 3 years. These were driven by a higher rate of TVR, MI and stent thrombosis in the BMS group at 3 years. There was a non-significant reduction in the overall and cardiac mortality [OR 0.83, 95% CI (0.60-1.14), OR 0.88, 95% CI (0.6-1.28)] with the use of second generation DES versus BMS at 3 years. Network meta-analysis of randomized trials of primary PCI demonstrated lower incidence of MACE, MI, TVR, and stent thrombosis with second generation DES compared with BMS. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  2. Expandable metallic ureteral stent: indications and results. Analysis of the current literature.

    Science.gov (United States)

    Sampogna, Gianluca; Grasso, Angelica; Montanari, Emanuele

    2018-03-28

    Ureteral obstructions are managed by complex surgery not always feasible for surgical field complexity or poor patient conditions. Various surgical maneuvers, as ureteral dilation, stenting and percutaneous nephrostomy, can be offered, but they are related to considerable failure rates and negative impact on quality of life. In selected cases, the positioning of long-term expandable metallic ureteral stents (EMUSs) may be an appropriate and successful choice. Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses criteria, a systematic review of the literature was performed in July 2017 using PubMed, Cochrane Library, Scopus and Web of Science databases. The search was conducted by typing the following terms: "Expandable metallic ureteral stent", "Memokath ureteral stent", "Allium ureteral stent" and "Uventa ureteral stent". Twenty studies reported the safety, efficacy and clinical outcomes related to the common available EMUSs. Most studies were single-arm, retrospective and involving a low number of clinical cases, resulting in significant difficulties with outlining indications and drawing conclusions. Available papers showed EMUSs offered a high rate of patency, a long duration and a good quality of life, even if they are associated with significant complications. Since the first description of ureteral stents 50 years ago, we have faced a significant evolution in stent design. The current generation of EMUSs offers many advantages, but the onset of adverse effects is still significant and limits their use to selected cases. Further research should be addressed to the realization of prospective, multi-institutional randomized clinical trials to highlight indications to manage appropriately ureteral obstructions.

  3. Placement of Endovascular Stent across the Branching Arteries: Long-term Serial Evaluation of Stent-tissue Responses Overlying the Arterial Orifices in an Experimental Study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Il; Chung, Jin Wook, E-mail: chungjw@snu.ac.kr [Seoul National University College of Medicine, Department of Radiology (Korea, Republic of); Kim, Hyun Beom [National Cancer Center of Korea, Department of Radiology and Center for Liver Cancer, Research Institute and Hospital (Korea, Republic of); Park, Jae Hyung [Seoul National University College of Medicine, Department of Radiology (Korea, Republic of); Seo, Jeong Wook [Seoul National University College of Medicine, Department of Pathology (Korea, Republic of); Kim, Hyo-Cheol; Jae, Hwan Jun; Lee, Whal [Seoul National University College of Medicine, Department of Radiology (Korea, Republic of)

    2012-10-15

    PurposeThis study was designed to investigate the effects of stenting across the branching arteries on the patency and stent-tissue responses over the branching arterial orifices. Methods: Thirteen dogs were observed after placing aortic stents across the celiac arteries (CA), superior mesenteric arteries (SMA), and renal arteries (RA). The animals were grouped according to stent types: large-cell group (n = 6) and small-cell group (n = 7). Angiography was performed to evaluate the branching artery patency at 2, 6, and 12 months after stent insertion, and the stent-tissue responses covering the orifices were evaluated on histopathologic examination. Results: All branching arteries were patent on follow-up angiography; however, three patterns of stent-tissue responses over the orifices were observed: neointimal layering, bridging septa, and papillary hyperplasia. Although neointimal layering and bridging septa were evenly observed, severe papillary hyperplasia was more frequent at SMA and CA than RA. Four RA showed less than 50% ostial patency, and localized infarct was observed in six kidneys (24%). The ostial patency tended to decrease with small-cell stent during the follow-up period. Conclusions: Various stent-tissue responses over the branching artery orifices are induced by the aortic stent covering the branching arteries and may not be easily detected by conventional angiography. Subclinical renal infarct also may occur despite patent renal angiography.

  4. Percutaneous Intraductal Radiofrequency Ablation for Clearance of Occluded Metal Stent in Malignant Biliary Obstruction: Feasibility and Early Results

    Energy Technology Data Exchange (ETDEWEB)

    Pai, Madhava, E-mail: madhava.pai@imperial.ac.uk [Hammersmith Hospital, Imperial College, HPB Unit, Department of Surgery (United Kingdom); Valek, Vlastimil; Tomas, Andrasina [University Hospital Brno Bohunice, Department of Radiology (Czech Republic); Doros, Attila [Semmelweis University, Radiology Unit, Department of Transplantation and Surgery (Hungary); Quaretti, Pietro [IRCCS Policlinico San Matteo, Department of Radiology (Italy); Golfieri, Rita; Mosconi, Cristina [University of Bologna, Department of Radiology, Policlinico S. Orsola-Malpighi (Italy); Habib, Nagy, E-mail: nagy.habib@imperial.ac.uk [Hammersmith Hospital, Imperial College, HPB Unit, Department of Surgery (United Kingdom)

    2013-07-11

    PurposeThe major complication occurring with biliary stents is stent occlusion, frequently seen because of tumour in-growth, epithelial hyperplasia, and sludge deposits, resulting in recurrent jaundice and cholangitis. We report a prospective study with the results of first in man percutaneous intraductal radiofrequency (RF) ablation to clear the blocked metal stents in patients with malignant biliary obstruction using a novel bipolar RF catheter.MethodsNine patients with malignant biliary obstruction and blocked metal stents were included. These patients underwent intraductal biliary RF ablation through the blocked metal stent following external biliary decompression with an internal–external biliary drainage.ResultsAll nine patients had their stent patency restored successfully without the use of secondary stents. Following this intervention, there was no 30-day mortality, haemorrhage, bile duct perforation, bile leak, or pancreatitis. Of the nine patients, six are alive and three patients are dead with a median follow-up of 122 (range 50–488) days and a median stent patency of 102.5 (range 50–321) days. Six patients had their stent patent at the time of last follow-up or death. Three patients with stent blockage at 321, 290, and 65 days postprocedure underwent percutaneous transhepatic drain insertion and repeat ablation.ConclusionsIn this selective group of patients, it appears that this new approach is safe and feasible. Efficacy remains to be proven in future, randomized, prospective studies.

  5. Newly developed biodegradable stents for benign gastrointestinal tract stenoses: a preliminary clinical trial.

    Science.gov (United States)

    Tanaka, Toyohiko; Takahashi, Masashi; Nitta, Norihisa; Furukawa, Akira; Andoh, Akira; Saito, Yasuharu; Fujiyama, Yoshihide; Murata, Kiyoshi

    2006-01-01

    We developed an Ultraflex-type stent by knitting polylactic acid monofilaments. The purpose of this study was to evaluate the stent's clinical usefulness for treating benign stenoses in the gastrointestinal tract. The radial force of the biodegradable stent was compared with those of commercially available metallic stents. The measured radial force of the new biodegradable stent was higher than that of commercially available metallic stents. The biodegradable stents were applied in 2 patients with benign gastrointestinal stenoses. The first patient was a 19-year-old female with esophageal stenosis, due to drinking of caustic potash in an attempt to commit suicide. The second patient was a 75-year-old male who had a stenosis at the anastomotic site after esophageal cancer resection. In both cases, the placement of the stent was performed successfully, and the patients' complaints improved immediately after stent placement. There were no complications during stent placement. The stenosis had not recurred at the six-month follow-up examination. In conclusion, the newly developed biodegradable stents were useful in treating benign stenoses of the alimentary tract. 2006 S. Karger AG, Basel

  6. Malignant Gastric and Duodenal Stenosis: Palliation by Peroral Implantation of a Self-Expanding Metallic Stent

    International Nuclear Information System (INIS)

    Pinto, Isabel T.

    1997-01-01

    Purpose: To assess the use of self-expanding metallic stents in patients with inoperable malignant antrum-pylorus-duodenal obstruction. Methods: Six patients underwent implantation of a Wallstent self-expanding metallic endoprosthesis (20 mm in five patients and 16 mm in one). In five patients a catheter (Berenstein) was introduced perorally into the stomach. A guidewire (Terumo) was introduced through the catheter and advanced through the antrum-pylorus-duodenal stenosis. The guidewire was removed and a 260-cm-long, 0.035'' superstiff guide (Amplatz) was introduced. After the catheter was removed the stent assembly was introduced. In the last patient the stent was implanted through a percutaneous gastrostomy. Results: Treatment of inoperable gastric outlet obstruction caused by tumor compression is difficult and unsatisfactory. Peroral implantation of self-expanding metallic stents resulted in successful palliative therapy of antrum-pylorus-duodenal stenosis in six patients in whom surgery was not possible because of advanced disease and poor general condition. On average, patients were able to eat during 41 days. One patient is tolerating oral intake at 3 months. Conclusion: Implantation of stents resulted in palliative relief of malignant antrum-pylorus-duodenal obstructions

  7. Drug-eluting stents and bare metal stents in patients with NSTE-ACS

    DEFF Research Database (Denmark)

    Pedersen, Sune Haahr; Pfisterer, Matthias; Kaiser, Christoph

    2014-01-01

    AIMS: The use of drug-eluting stents (DES) in patients with non-ST-segment elevation acute coronary syndrome (NSTE-ACS) is controversial and not yet endorsed in clinical guidelines. METHODS AND RESULTS: This was an a priori planned post hoc analysis involving 754 NSTE-ACS patients from...... implantation in large vessels was associated with a reduction in both TVR and the combined endpoint consisting of cardiovascular death/MI. Thus, DES use improves both efficacy and safety. These findings support the use of DES in NSTE-ACS patients....... endpoint, and clinically indicated target vessel revascularisation (TVR) and stent thrombosis. Compared to patients with BMS, those treated with SES and EES had a strong trend towards lower two-year rates of the primary endpoint (HR: 0.31 [CI: 0.11-0.90], p=0.03, and HR: 0.74 [CI: 0.44-1.24], p=0...

  8. Drug-eluting stents in renal artery stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Zaehringer, M. [Marienhospital Stuttgart, Department of Radiology, Stuttgart (Germany); Pattynama, P.M.T. [Erasmus MC-University Medical Center Rotterdam, Rotterdam (Netherlands); Talen, A. [genae associates nv, Antwerp (Belgium); Sapoval, M. [Hopital Europeen Georges Pompidou, Service de Radiologie Cardio-Vasculaire, Paris (France); Inserm U 780 epidemiologie Cardio Vasculaire, Paris (France)

    2008-04-15

    Because of higher acute and long-term success rates compared with balloon angioplasty alone, percutaneous stent implantation has become an accepted therapy for the treatment of atherosclerotic renal artery stenosis. Restenosis rates after successful renal stent placement vary from 6 up to 40%, depending on the definition of restenosis, the diameter of the treated vessel segment and comorbidities. The safety and efficacy of drug-eluting stents for the treatment of renal-artery stenosis is poorly defined. The recently published GREAT study is the only prospective study, comparing bare-metal and sirolimus-coated low profile stent systems in renal artery stenosis, showing a relative risk reduction of angiographic binary in-stent restenosis by 50%. This is an opinion paper on indications, current treatment options and restenosis rates following renal artery stenting and the potential use of drug-eluting stents for this indication. (orig.)

  9. The Effect of Ureteral Stent Placement Before Radical Prostatectomy on the Safety of Ureteral Dissection and the Surgeon’s Comfort

    Directory of Open Access Journals (Sweden)

    Fatih Akdemir

    2017-09-01

    Full Text Available Objective: This study investigated the role of preoperative ureteral stent placement in reducing the risk of ureteral injury, an intraoperative complication of radical retropubic prostatectomy (RRP, and its contribution to the surgeon’s comfort. Materials and Methods: Open RRP was performed in 66 patients diagnosed with localized prostate cancer in our clinic between 2010 and 2015. The patients were divided into two groups; group 1 (n=34 underwent surgery without ureteral stent placement and group 2 (n=32 had surgery following the placement of a ureteral stent. The cases were preoperatively evaluated by suprapubic and transrectal ultrasonography. Perioperative and postoperative complications of all cases were determined. Both groups were assessed in terms of ureteral injury, operative time, and surgeon’s comfort. Results: The mean age of the patients in group 1 and group 2 was 61.12±5.92 (50-72 years and 63.58±6.2 (51-75 years, respectively. The mean prostate volume was 76.8±2.41 and 72.4±3.53 cc in groups 1 and 2, respectively. The mean operative time was 143.9±3.06 minutes in group 1 and 136.8±2.83 minutes in group 2. Partial ureteral injury occurred in three patients in group 1 and was repaired intraoperatively. Of these patients, two had previously undergone radiotherapy for prostate cancer and it was difficult to perform prostate dissection intraoperatively. The remaining patient had a history of transurethral resection of the prostate. No ureteral injury was observed in any of the patients in group 2. Conclusion: Preoperative ureteral stent placement in selected patients can facilitate ureteral dissection and reduce ureteral injury risk.

  10. Outcomes of Percutaneous Management of Anastomotic Ureteral Strictures in Renal Transplantation: Chronic Nephroureteral Stent Placement with and without Balloon Dilatation

    Energy Technology Data Exchange (ETDEWEB)

    Uflacker, A., E-mail: andreuflacker@gmail.com; Sheeran, D., E-mail: dsheeran9@gmail.com; Khaja, M., E-mail: mkhaja@mac.com [University of Virginia/Interventional Radiology (United States); Patrie, J., E-mail: jp4h@virginia.edu [UVA Health System/Radiology (United States); Elias, G., E-mail: gae2y@virginia.edu [VCU Medical Center/Radiology (United States); Saad, W., E-mail: wspikes@yahoo.com [University of Michigan Health System (United States)

    2015-06-15

    PurposeThis study was designed o evaluate outcomes of percutaneous management of anastomotic ureteral strictures in renal transplants using nephroureteral stents with or without balloon dilatation.MethodsA retrospective audit of 1,029 consecutive renal transplants was performed. Anastomotic ureteral strictures were divided into two groups: nephroureteral stent only (NUS) and NUS+PTA (nephroureteral stent plus percutaneous transluminal angioplasty), with each cohort subdivided into early versus late presentation (obstructive uropathy occurring <90 day or >90 days from transplant, respectively). Overall and 6-month technical success were defined as removal of NUS any time with <30 % residual stenosis (any time lapse less or more than 6 months) and at >6 months, respectively. Patency was evaluated from NUS removal to last follow-up for both groups and compared.ResultsSixty-seven transplant patients with 70 ureteric anastomotic strictures (6.8 %, n = 70/1,029) underwent 72 percutaneous treatments. 34 % were late (>90 days, n = 24/70), and 66 % were early (<90 days, n = 46/70). Overall technical success was 82 % (n = 59/72) and 6-month success was 58 % (n = 42/72). Major and minor complications were 2.8 % (n = 2/72), and 12.5 % (n = 9/72). NUS+PTA did not improve graft survival (p = 0.354) or patency (p = 0.9) compared with NUS alone. There was no difference in graft survival between treated and nontreated groups (p = 0.74).ConclusionsThere is no advantage to PTA in addition to placement of NUS, although PTA did not negatively impact graft survival or long-term patency and both interventions were safe and effective. Neither the late or early groups benefited from PTA in addition to NUS. Earlier obstructions showed greater improvement in serum creatinine than later obstructions.

  11. Endoluminal stenting for the management of leak following sleeve gastrectomy and loop duodenojejunal bypass with sleeve gastrectomy

    Directory of Open Access Journals (Sweden)

    Ying-Nan Tsai

    2018-01-01

    Full Text Available Postoperative leak is a serious complication of bariatric surgery and often results in significant morbidity and mortality. Stent placement is a less invasive alternative to surgery for the treatment of bariatric surgical leak. We evaluated the efficacy and complications of covered self-expandable metal stents (SEMS in the treatment of post-bariatric surgical leak. We retrospectively reviewed patients who underwent stent placement for leak after bariatric surgery. Leak was diagnosed by upper gastrointestinal series or was visualized during the endoscopy. We examined the timing of stent placement, size of the leak, stent migration and its complications, total stent treatment duration, and treatment outcome. Between January 2011 and April 2015, seven patients underwent covered SEMS placement for leak after bariatric surgery, including laparoscopic sleeve gastrectomy (LSG (n = 5 and laparoscopic loop duodenojejunal bypass with sleeve gastrectomy (LDJB-SG (n = 2. A stent was placed in one patient for infection control and bridging to revisional surgery. Among the other six patients, one patient who received stent placement one year after leak diagnosis failed to achieve leak closure, and five patients with early stent placement achieved leak closure. Three patients with small leak achieved leak closure more quickly. Stent migration was found in six patients, and associated ulcers occurred in five patients. We conclude that stenting is effective in the management of staple-line leaks following LSG and LDJB-SG. Stent migration and associated ulcers are common after stent placement. Early stent removal can be achieved in patients with small leaks.

  12. EW-7197 eluting nano-fiber covered self-expandable metallic stent to prevent granulation tissue formation in a canine urethral model

    Science.gov (United States)

    Yang, Su-Geun; Tsauo, Jiaywei; Kim, Kun Yung; Kim, Min Tae; Gang, Sung Gwon; Kim, Dae-Kee; Kim, Dong-Hyun; Song, Ho-Young

    2018-01-01

    Purpose To evaluate an EW-7197-eluting nanofiber-covered stent (NFCS) for suppressing granulation tissue formation after stent placement in a canine urethral model. Materials and methods All experiments were approved by the committee of animal research. A total of 12 NFCSs were placed in the proximal and distal urethras of six dogs. Dogs were divided into two groups with 3 dogs each. The control stent (CS) group received NFCSs and the drug stent (DS) group received EW-7197 (1000 μg)-eluting NFCSs. All dogs were sacrificed 8 weeks after stent placement Histologic findings of the stented urethra were compared using the Mann-Whitney U test. Results Stent placement was technically successful in all dogs without procedure-related complications. On urethrographic analysis, the mean luminal diameter was significantly larger in the DS group than in the CS group at 4 and 8 weeks after stent placement (all p 0.05). Conclusion The EW-7197-eluting NFCS is effective and safe for suppressing granulation tissue formation after stent placement in a canine urethral model. PMID:29447198

  13. Sustained benefit at 2 years for covered stents versus bare-metal stents in long SFA lesions: the VIASTAR trial.

    Science.gov (United States)

    Lammer, Johannes; Zeller, Thomas; Hausegger, Klaus A; Schaefer, Philipp J; Gschwendtner, Manfred; Mueller-Huelsbeck, Stefan; Rand, Thomas; Funovics, Martin; Wolf, Florian; Rastan, Aljoscha; Gschwandtner, Michael; Puchner, Stefan; Beschorner, Ulrich; Ristl, Robin; Schoder, Maria

    2015-02-01

    The hypothesis that covered stents are superior to bare-metal stents (BMS) in long femoropopliteal artery disease was tested. The one-year results of the VIASTAR trial revealed a patency benefit of covered stents in the treatment-per-protocol (TPP) analysis only. A prospective, randomized, single-blind, multicenter study evaluated 141 patients with symptomatic peripheral arterial disease (PAD) after treatment with heparin-bonded covered stents (VIABAHN(®) Endoprosthesis) or BMS. Clinical outcomes and patency rates were assessed at 1, 6, 12, and 24 months. Mean lesion length was 19.0 ± 6.3 cm in the VIABAHN(®) versus 17.3 ± 6.6 cm in the BMS group. The 24-month primary patency rates in the VIABAHN(®) and BMS group were: intention-to-treat 63.1 (95 % CI 0.52-0.76) versus 41.2 % (95 % CI 0.29-0.57; log rank p = 0.04) and TPP 69.4 (95 % CI 0.58-0.83) versus 40.0 % (95 % CI 0.28-0.56; log rank p = 0.004). Freedom from target-lesion-revascularization (TLR) was 79.4 (95 % CI 0.70-0.90) versus 73.0 % (95 % CI 0.63-0.85) for VIABAHN(®) versus BMS (log rank p = 0.37). For the TPP group in lesions ≥20 cm, the 24-month patency rates were 65.2 (95 % CI 0.50-0.85) versus 26.7 % (95 % CI 0.12-0.59; log rank p = 0.004) for VIABAHN(®) versus BMS, and freedom from TLR was 80.0 (95 % CI 0.68-0.94) versus 61.9 % (95 % CI 0.44-0.87; log rank p = 0.13). The ankle brachial index was 0.89 ± 0.18 versus 0.91 ± 0.17 (p = 0.76) at 24-month in the VIABAHN(®) versus the BMS group, respectively. At 24-month, this trial in PAD patients with long femoropopliteal lesions demonstrated a significantly improved primary patency rate for heparin-bonded covered stents compared to BMS, however, without a significant impact on clinical outcomes and TLR rate (Reg. Nr. ISRCTN48164244).

  14. Percutaneous transhepatic self-expanding metal stents for palliation ...

    African Journals Online (AJOL)

    Nine patients (18%) developed a procedure-related complication, which included cholangitis after stent insertion (n=4), cholangitic liver abscesses (n=1), subphrenic liver collection (n=1), bile leakage (n=1) and cholecystitis (n=2). Three patients (6%) developed complications unrelated to SEMS insertion, which included ...

  15. Treatment of malignant esophageal obstructions with covered metallic Z stents: long-term results in 52 patients.

    Science.gov (United States)

    Saxon, R R; Barton, R E; Katon, R M; Petersen, B D; Lakin, P C; Timmermans, H; Uchida, B; Keller, F S; Rösch, J

    1995-01-01

    To prospectively evaluate the clinical efficacy of silicone-covered Gianturco-Rösch self-expandable Z (GRZ) stents in the treatment of malignant esophageal obstruction. GRZ stents were placed in 52 patients (39 men, 13 women) with severe dysphagia due to high-grade malignant esophageal obstruction. Stent placement was technically successful, and immediate relief of dysphagia was achieved in 50 of 52 patients (96%), with long-term relief in 47 patients (90%). Fifty-one patients (98%) died during follow-up (range, 1 week to 33 months; mean, 4.3 months). Late complications were most prevalent and included stent migration (n = 5), food impaction (n = 2), chest pain (n = 2), membrane disruption with tumor ingrowth (n = 1), granulomatous reaction above the stent (n = 1), esophageal perforation with mediastinitis (n = 1), and upper gastrointestinal hemorrhage (n = 4). Twelve complications were easily managed with medical, endoscopic, or radiologic intervention. Four deaths may have been related to stent placement (early mortality rate, 7.7%). GRZ stents provide relatively safe and effective long-term palliation in patients with severe, malignant esophageal obstruction.

  16. Bronchial stents

    Directory of Open Access Journals (Sweden)

    Ibrahim Emad

    2006-01-01

    Full Text Available Bronchial stents are mostly used as a Palliative relief of symptoms often caused by airway obstruction, It is also used for sealing of stump fistulas after pneumonectomy and dehiscence after bronchoplastic operations. Advances in airway prosthetics have provided a variety of silicone stents, expandable metal stents, and pneumatic dilators, enabling the correction of increasingly complex anatomical problems. Several series have been published describing the application and results of these techniques. This manuscript reviews the historical development of stents, types, indication, outcome, and complications. Alternative therapies for tracheobronchial stenting were also reviewed

  17. Trial of self-expandable metallic stents in the palliation of tracheo ...

    African Journals Online (AJOL)

    Trial of self-expandable metallic stents in the palliation of tracheo-oesophageal fistula in carcinoma of the oesophagus. ... Over half of the patients in the TOF group had concomitant pneumonia at presentation with decreased survival (p = 0.010) and a hazard ratio of 10.86. Two patients died, on days 4 and 7 respectively.

  18. Meta-Analysis of Comparison of Drug-Eluting Stents and Bare-Metal Stents in Patients on Dialysis.

    Science.gov (United States)

    Li, Shan; Ye, Dan; Chen, Guoping; Xu, Weiwei

    2017-04-15

    Coronary artery disease is common in patients with end-stage renal disease who are on hemodialysis. The efficacy and safety of evidence regarding the use of drug-eluting stents (DES) and bare-metal stents (BMS) in patients with dialysis is unclear. We searched MEDLINE, EMBASE, Science Citation Index, CINAHL, and the Cochrane CENTRAL database of controlled clinical trials for controlled trials that compare DES and BMS in dialysis patients up to June 2016. We conducted a meta-analysis across 14 eligible studies (n = 62,250 patients). In general, DES-treated patients demonstrate a lower risk of the clinical adverse events compared with those treated with BMS. Significant reduction in the incidence of death (odds ratio [OR] 0.77, CI 0.64 to 0.92) and major adverse cardiovascular events (OR 0.65, CI 0.57 to 0.74) and target lesion/vessel revascularization (OR 0.83, CI 0.73 to 0.94), and a trend toward lower OR for myocardial infarction (OR 0.95, CI 0.87 to 1.02) were noted in DES-treated patients. In conclusion, the use of DES in patients with dialysis yields significant decrease in the risk of mortality, major adverse cardiovascular events, and target lesion/vessel revascularization. Larger randomized studies are needed to confirm the results of this meta-analysis and establish the appropriate stent choice in this high-risk population. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. A strain-mediated corrosion model for bioabsorbable metallic stents.

    Science.gov (United States)

    Galvin, E; O'Brien, D; Cummins, C; Mac Donald, B J; Lally, C

    2017-06-01

    This paper presents a strain-mediated phenomenological corrosion model, based on the discrete finite element modelling method which was developed for use with the ANSYS Implicit finite element code. The corrosion model was calibrated from experimental data and used to simulate the corrosion performance of a WE43 magnesium alloy stent. The model was found to be capable of predicting the experimentally observed plastic strain-mediated mass loss profile. The non-linear plastic strain model, extrapolated from the experimental data, was also found to adequately capture the corrosion-induced reduction in the radial stiffness of the stent over time. The model developed will help direct future design efforts towards the minimisation of plastic strain during device manufacture, deployment and in-service, in order to reduce corrosion rates and prolong the mechanical integrity of magnesium devices. The need for corrosion models that explore the interaction of strain with corrosion damage has been recognised as one of the current challenges in degradable material modelling (Gastaldi et al., 2011). A finite element based plastic strain-mediated phenomenological corrosion model was developed in this work and was calibrated based on the results of the corrosion experiments. It was found to be capable of predicting the experimentally observed plastic strain-mediated mass loss profile and the corrosion-induced reduction in the radial stiffness of the stent over time. To the author's knowledge, the results presented here represent the first experimental calibration of a plastic strain-mediated corrosion model of a corroding magnesium stent. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  20. Membrane-like structure in the urinary bladder neck of a young cat: diagnosis and treatment using balloon dilatation and a balloon-expandable metallic stent

    Directory of Open Access Journals (Sweden)

    Matias Ruiz-Drebing

    2017-10-01

    Full Text Available Case summary A 33-month-old, spayed female domestic shorthair cat was referred to the Animal Health Trust for the investigation of urinary incontinence and straining to urinate. A membrane-like structure was detected in the bladder neck, which caused partial obstruction of the urinary bladder. A combination of different imaging techniques, including ultrasonography, radiography, CT and fluoroscopy, was essential in the diagnosis, surgical planning and treatment of this intravesicular stricture. During retrograde vaginourethrocystogram, unexpected subcapsular accumulation of contrast medium was seen around both kidneys on radiographs and confirmed with CT. Three different treatments were performed, including surgical debridement, balloon dilatation and placement of a self-expanding metallic stent across the stricture. Histopathology of the membrane was unable to differentiate whether the lesion was congenital or acquired. No urinary incontinence was observed 5 months after placement of the metallic stent. Relevance and novel information This is the first reported case using fluoroscopic-guided balloon dilatation of the bladder neck for the treatment of a bladder neck stricture. Presence of renal subcapsular contrast medium secondary to a retrograde vaginourethrocystogram due to partial obstruction at the bladder neck in a cat has not been previously described.

  1. Long-term outcome after drug-eluting versus bare-metal stent implantation in patients with ST-segment elevation myocardial infarction

    DEFF Research Database (Denmark)

    Holmvang, Lene; Kelbæk, Henning; Kaltoft, Anne Kjer

    2013-01-01

    This study sought to compare the long-term effects of drug-eluting stent (DES) compared with bare-metal stent (BMS) implantation in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention.......This study sought to compare the long-term effects of drug-eluting stent (DES) compared with bare-metal stent (BMS) implantation in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention....

  2. Ultraflex precision colonic stent placement as a bridge to surgery in patients with malignant colon obstruction

    DEFF Research Database (Denmark)

    Fregonese, D.; Naspetti, R.; Ferrer, S.

    2008-01-01

    colorectal SEMS may offer several advantages, but available evidence on the utility of this SEMS type remains highly limited. Objective: Our purpose was to evaluate the effectiveness and safety as a bridge to surgery of a nitinol SEMS designed for colorectal use. Design: Prospective and retrospective...... success in alleviating colonic obstructive symptoms, and bridging to elective surgery. Results: Technical success was achieved in 97% of patients with a 95% CI of 85% to 100% and clinical success in 81% (95% CI, 64%-92%). Elective surgery was performed in 94% (95% CI, 81%-99%) of patients at a median...... of 11 days (95% CI, 7-15 days) after SEMS placement. SEMS-related perforation occurred in 3 patients. Limitations: No control group was included in this nonrandomized cohort study. Conclusions: In this first comparatively large clinical study of a nitinol colorectal SEMS as a bridge to surgery, a high...

  3. Fully covered self-expanding metal stents are effective for benign esophagogastric disruptions and strictures.

    Science.gov (United States)

    Wilson, Jennifer L; Louie, Brian E; Farivar, Alexander S; Vallières, Eric; Aye, Ralph W

    2013-12-01

    Self-expanding fully covered metal stents (CSs) are ideal for use in benign esophagogastric disease. We reviewed our experience with CS to evaluate outcomes, to determine a role for CS in a standard treatment for benign esophageal conditions, and to compare our results with recently published studies. We performed a retrospective chart review from 2005 to 2012. A total of 57 CSs were placed in 44 patients. Indications were stricture (11 patients), anastomotic leak (20), perforation (7), and tracheoesophageal fistulae (6). For GI tract disruptions, open repair or diversion was avoided in 31/33 patients (93.9 %) but required an associated drainage procedure in 22/33 (67 %) patients. Resolution does not depend on achieving radiological control with 6/26 (23 %) having evidence of a persistent leak. Benign strictures were dilated at a mean of 3.7 times prior to stenting. Adjunctive intra-mucosal steroid injections were used in 8/11 patients. Stents were removed at a mean of 33 days. At a mean of 283 days of follow-up, 6/11 (54.5 %) had symptom resolution. The most common complication was stent migration occurring in 17.5 % of patients overall. Covered stents are an effective adjunct in the management of benign upper gastrointestinal tract fistulae, leaks, perforations and benign strictures.

  4. Treatment of tracheobronchial stenosis with a self-expandable metallic stents

    International Nuclear Information System (INIS)

    Kim, Yong Soo; Jeon, Seok Chol; Choi, Chul Seung; Choi, Yo Won; Hahm, Chang Kok

    1994-01-01

    We analysed the role of modified Gianturco self-expandable stents in the treatment of tracheobronchial stenosis in 13 patients. We inserted modified Gianturco self-expandable stents under the fluoroscopic and bronchoscopic guidance. There were stenosis in the trachea(n=2), the right main bronchus(n=2), and the left main bronchus(n=9). The causes of the stenosis were endobronchial tuberculosis(n=10), intubation granuloma(n=1), restenosis after surgical reconstruction(n=2). Dyspnea or wheezing was improved within 1 or 2 days following the procedure. There were 32% and 22% respective increase in average FEV1 and FVC. Lung perfusion scan showed 9.6% increase of perfusion in the involved lung. No complications related to the procedure were encountered. During follow-up period of up to 31 months, 2 patients showed tracheal or bronchial restenosis, at 3 and 6 months, retrospectively. There was a distal migration of the stents in one case. During the follow up period after stent insertion, improvement of the obstructive changes and dyspnea persisted in 10 out of 13 patients. The modified Gianturco self-expandable metallic stents may be a good choice for the treatment of tracheobronchial stenosis, either as a primary treatment, or when the reconstruction failed

  5. Interdisciplinary Canadian guidelines on the use of metal stents in the gastrointestinal tract for oncological indications

    International Nuclear Information System (INIS)

    Baerlocher, M.O.; Asch, M.R.; Dixon, P.; Kortan, P.; Myers, A.; Law, C.

    2008-01-01

    To provide evidence-based guidelines regarding the appropriate use of gastrointestinal stents for oncologic indications. This document describes the use of gastrointestinal stents by appropriately trained physicians. This document is based on a review of the published evidence and supplemented by consensus expert opinion. Gastrointestinal stenting has been evaluated in terms of technical success, complications, patient satisfaction, clinical outcome, and cost-benefit analysis. This document was approved by the Canadian Interventional Radiology Association; approval from the other relevant Canadian societies is pending. Gastrointestinal stenting has a valuable role in the management of the gastrointestinal malignancy. The decision to use such devices should be taken after comprehensive multidisciplinary clinical, endoscopic, and radiologic evaluation. This interdisciplinary Canadian guideline on the use of metal stents in the gastrointestinal tract for ontological indications is based on a scientific literature review and relevant clinical experience. This guideline attempts to define principles of practice for most circumstances, though adherence to this guideline will not, of course, produce successful outcomes in every case. (author)

  6. Interdisciplinary Canadian guidelines on the use of metal stents in the gastrointestinal tract for oncological indications

    Energy Technology Data Exchange (ETDEWEB)

    Baerlocher, M.O. [Dept. of Radiology, Univ. of Toronto, Toronto, Ontario (Canada)], E-mail: mark.baerlocher@utoronto.ca; Asch, M.R. [Dept. of Diagnostic Imaging, Lakeridge Health Corp., Oshawa, Ontario (Canada); Dixon, P. [Dept. of Radiation Oncology, Durham Regional Cancer Centre, Oshawa, Ontario (Canada); Dept. of Oncology, Queen' s Univ., Kingston, Ontario (Canada); Kortan, P. [Div. of Gastroenterology, Dept. of Medicine, St. Michael' s Hospital, Toronto, Ontario (Canada); Myers, A. [Dept. of Diagnostic Imaging, Lakeridge Health Corp., Oshawa, Ontario (Canada); Law, C. [Dept. of Surgical Oncology, Div. of General Surgery, Sunnybrook HSC, Toronto, Ontario (Canada)

    2008-06-15

    To provide evidence-based guidelines regarding the appropriate use of gastrointestinal stents for oncologic indications. This document describes the use of gastrointestinal stents by appropriately trained physicians. This document is based on a review of the published evidence and supplemented by consensus expert opinion. Gastrointestinal stenting has been evaluated in terms of technical success, complications, patient satisfaction, clinical outcome, and cost-benefit analysis. This document was approved by the Canadian Interventional Radiology Association; approval from the other relevant Canadian societies is pending. Gastrointestinal stenting has a valuable role in the management of the gastrointestinal malignancy. The decision to use such devices should be taken after comprehensive multidisciplinary clinical, endoscopic, and radiologic evaluation. This interdisciplinary Canadian guideline on the use of metal stents in the gastrointestinal tract for ontological indications is based on a scientific literature review and relevant clinical experience. This guideline attempts to define principles of practice for most circumstances, though adherence to this guideline will not, of course, produce successful outcomes in every case. (author)

  7. Upper Gastrointestinal Stent

    OpenAIRE

    Kim, Sang Gyun; Yang, Chang-Hun

    2012-01-01

    Gastrointestinal (GI) stent has been developed for palliation of obstructive symptoms in various diseases causing obstruction of GI tract. Self-expanding metal stent (SEMS) has replaced old type of plastic stent, and endoscopic insertion of stent has replaced fluoroscopy-guided insertion. Nowadays, newly-designed SEMSs have been developed for prevention of complications such as stent migration and re-obstruction, and indications of stent recently have been widened into benign conditions as we...

  8. Impact of carcinomatosis and ascites status on long-term outcomes of palliative treatment for patients with gastric outlet obstruction caused by unresectable gastric cancer: stent placement versus palliative gastrojejunostomy.

    Science.gov (United States)

    Park, Chan Hyuk; Park, Jun Chul; Kim, Eun Hye; Chung, Hyunsoo; An, Ji Yeong; Kim, Hyoung-Il; Shin, Sung Kwan; Lee, Sang Kil; Cheong, Jae-Ho; Hyung, Woo Jin; Lee, Yong Chan; Noh, Sung Hoon; Kim, Choong Bae

    2015-02-01

    Self-expandable metal stent (SEMS) placement and palliative gastrojejunostomy (GJJ) are palliative treatment options for malignant gastric outlet obstruction. To compare clinical outcomes of palliative treatments for gastric outlet obstruction caused by unresectable gastric cancer. Retrospective study. University-affiliated tertiary-care hospital in the Republic of Korea. Two hundred fifty-six patients with gastric outlet obstruction caused by unresectable gastric cancer. SEMS placement and palliative GJJ. Patency duration and overall survival duration. In total, 217 and 39 patients underwent SEMS placement and palliative GJJ, respectively, as an initial palliative treatment. Treatment modality affected reobstruction after clinical success (hazard ratio [HR] [95% confidence interval {CI}], 0.5 [0.3-0.8] of palliative GJJ). In addition, carcinomatosis with ascites was an independent associated factor of clinical success and reobstruction (HR [95% CI], 0.3 [0.1-0.7] and 1.4 [1.0-2.0], respectively). In a subgroup of patients with good performance who had neither carcinomatosis nor ascites, patency duration and overall survival duration did not differ between the 2 groups (P = .079 and P = .290, respectively). In patients with good performance who had carcinomatosis without ascites, patency duration was longer in the palliative GJJ group than in the SEMS placement group (P = .016). Overall survival, however, did not differ between the 2 groups (P = .062). In a subgroup of patients with good performance who had carcinomatosis with ascites, both patency duration and overall survival were longer in the palliative GJJ group than in the SEMS placement group (P = .007 and P = .012, respectively). Nonrandomized, retrospective study. Long-term clinical outcomes of the palliative treatment modality for gastric outlet obstruction caused by unresectable gastric cancer were affected by carcinomatosis and ascites status. Copyright © 2015 American Society for

  9. Comparison of Laparoscopic versus Open Surgery after Insertion of Self-Expandable Metallic Stents in Acute Malignant Colorectal Obstruction: A Case-Matched Study

    Directory of Open Access Journals (Sweden)

    Chotirot Angkurawaranon

    2017-03-01

    Full Text Available Background: Self-expanding metallic stents (SEMS have been acknowledged in management of acute colorectal obstruction. The surgical approach after SEMS insertion varies from open approach to laparoscopic-assisted approach. The primary objective of this study was to compare the outcomes of laparoscopic approach and open approach after SEMS insertion. Methods: From January 2007 to December 2010, cross-sectional medical records reviewed a total of 76 patients who underwent colorectal stenting with SEMS. Patients and tumor characteristics, complications, morbidity and mortality were obtained. Results: Forty-three patients underwent SEMS placement as a bridge to surgery. Laparoscopic-assisted surgery (LS was performed in 24 patients (55.8%, and open surgery (OS was performed in 19 patients (44.2%. All clinicopathological parameters were matched. The technical success of SEMS was found in 42 patients (97.7%, and the clinical stent success was 100%. LS had a higher chance of primary anastomosis than OS (p=0.012; Odd ratio 2.717; 95%CI: 1.79-4.012. LS had a lower permanent ostomy rate (p=0.031; Odd ratio 0.385; 95%CI: 0.259-0.572 and lower estimated blood loss (p=0.024; Odd ratio 0.23; 95%CI: 0.006-0.086. The post-operative complications, mortality rate, recurrence rate, disease free status, and overall survival rates between the two groups were non-significant. Conclusion: Colonic stent is an effective treatment of acute malignant colonic obstruction. The authors suggest the advantage of laparoscopic approach resection after colonic stenting results in a higher primary anastomosis rate, and lower blood loss than open surgery.

  10. Self-expanding metallic stent as a bridge to surgery in the treatment of left colon cancer obstruction: Cost-benefit analysis and oncologic results.

    Science.gov (United States)

    Flor-Lorente, Blas; Báguena, Gloria; Frasson, Matteo; García-Granero, Alvaro; Cervantes, Andrés; Sanchiz, Vicente; Peña, Andres; Espí, Alejandro; Esclapez, Pedro; García-Granero, Eduardo

    2017-03-01

    The use of a self-expanding metallic stent as a bridge to surgery in acute malignant left colonic obstruction has been suggested as an alternative treatment to emergency surgery. The aim of the present study was to compare the morbi-mortality, cost-benefit and long-term oncological outcomes of both therapeutic options. This is a prospective, comparative, controlled, non-randomized study (2005-2010) performed in a specialized unit. The study included 82 patients with left colon cancer obstruction treated by stent as a bridge to surgery (n=27) or emergency surgery (n=55) operated with local curative intention. The main outcome measures (postoperative morbi-mortaliy, cost-benefit, stoma rate and long-term oncological outcomes) were compared based on an "intention-to-treat" analysis. There were no significant statistical differences between the two groups in terms of preoperative data and tumor characteristics. The technically successful stenting rate was 88.9% (11.1% perforation during stent placement) and clinical success was 81.4%. No difference was observed in postoperative morbi-mortality rates. The primary anastomosis rate was higher in the bridge to surgery group compared to the emergency surgery group (77.8% vs. 56.4%; P=.05). The mean costs in the emergency surgery group resulted to be €1,391.9 more expensive per patient than in the bridge to surgery group. There was no significant statistical difference in oncological long-term outcomes. The use of self-expanding metalllic stents as a bridge to surgery is a safe option in the urgent treatment of obstructive left colon cancer, with similar short and long-term results compared to direct surgery, inferior mean costs and a higher rate of primary anastomosis. Copyright © 2017 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Fabrication of a silver particle-integrated silicone polymer-covered metal stent against sludge and biofilm formation and stent-induced tissue inflammation.

    Science.gov (United States)

    Lee, Tae Hoon; Jang, Bong Seok; Jung, Min Kyo; Pack, Chan Gi; Choi, Jun-Ho; Park, Do Hyun

    2016-10-14

    To reduce tissue or tumor ingrowth, covered self-expandable metal stents (SEMSs) have been developed. The effectiveness of covered SEMSs may be attenuated by sludge or stone formation or by stent clogging due to the formation of biofilm on the covering membrane. In this study, we tested the hypothesis that a silicone membrane containing silver particles (Ag-P) would prevent sludge and biofilm formation on the covered SEMS. In vitro, the Ag-P-integrated silicone polymer-covered membrane exhibited sustained antibacterial activity, and there was no definite release of silver ions from the Ag-P-integrated silicone polymer membrane at any time point. Using a porcine stent model, in vivo analysis demonstrated that the Ag-P-integrated silicone polymer-covered SEMS reduced the thickness of the biofilm and the quantity of sludge formed, compared with a conventional silicone-covered SEMS. In vivo, the release of silver ions from an Ag-P-integrated silicone polymer-covered SEMS was not detected in porcine serum. The Ag-P-integrated silicone polymer-covered SEMS also resulted in significantly less stent-related bile duct and subepithelium tissue inflammation than a conventional silicone polymer-covered SEMS. Therefore, the Ag-P-integrated silicone polymer-covered SEMS reduced sludge and biofilm formation and stent-induced pathological changes in tissue. This novel SEMS may prolong the stent patency in clinical application.

  12. Endoscopic treatment of anastomotic biliary complications after liver transplantation using removable, covered, self-expandable metallic stents.

    Science.gov (United States)

    Haapamäki, Carola; Udd, Marianne; Halttunen, Jorma; Lindström, Outi; Mäkisalo, Heikki; Kylänpää, Leena

    2012-01-01

    Anastomotic bile duct complications after liver transplantation (LT) have been treated endoscopically by dilation and plastic tube stenting, with the stent therapy having moved toward using covered, self-expandable metallic stents (cSEMS) in recent years. The aim of this study was to analyze therapy outcome of post-LT anastomotic complications using cSEMS. Seventeen post-LT patients had 29 cSEMS (Allium stent, n = 23; Wallstent, n = 4; Micro-Tech, n = 2) placed during endoscopic retrograde cholangiopancreatography (ERCP). The fully covered stents (Allium, Micro-Tech) were placed entirely inside the common bile duct. Data were collected and analyzed in a retrospective manner. These 17 patients had 19 stent treatment periods. Resolution was eventually established in all patients. There were four (14%) stent migrations. Pancreatitis was seen after one ERCP procedure, whereas five cases of cholangitis were seen. Treatment of post-LT anastomotic complications with cSEMS seems to be both safe and efficient. Further assessment regarding indications, stent types and stenting time is needed.

  13. High proximal migration rate of a partially covered "big cup" duodenal stent in patients with malignant gastric outlet obstruction

    NARCIS (Netherlands)

    van den Berg, Maarten W.; Walter, Daisy; Vleggaar, Frank P.; Siersema, Peter D.; Fockens, Paul; van Hooft, Jeanin E.

    2014-01-01

    Endoscopic placement of self-expandable metal stents (SEMS) has emerged as a palliative treatment for patients with malignant gastric outlet obstruction (GOO). Recently, a new partially covered "big cup" SEMS has been developed to prevent both stent migration and tissue ingrowth. The aim of the

  14. Initial experience with Allium™ stent in the management of bulbar urethral stricture

    Science.gov (United States)

    Silagy, Andrew; Merrett, Chris

    2017-01-01

    We herein present our initial experience of a short series with the Allium™ Bulbar Urethral Stent (BUS) in the management of bulbar urethral disease. This Allium™ stent is a self-expandable metal stent which is intended for temporary placement. Our series is a retrospective analysis of 15 BUS placements in 13 patients conducted during 2014 to 2016. BUS was placed successfully after visual internal urethrotomy (VIU) in all patients. Stent insertion was successful in 8 patients (62%) with a mean follow up of 7.2 months (range, 2–12 months). Two of the failed patients stents were reinserted had repeat stenting with a successful outcome. The result of this short series suggests that BUS may have a limited role in the management of bulbar urethral stricture disease. PMID:28791227

  15. MRI Artifacts of a Metallic Stent Derived From a Human Aorta Specimen

    International Nuclear Information System (INIS)

    Soto, M. E.; Flores, P.; Marrufo, O.; Hidalgo, S. S.; Rodriguez, A. O.

    2010-01-01

    Magnetic resonance imaging has proved to be a useful technique to get images of the whole body. However, the presence of ferromagnetic material can cause susceptibility artifacts, which result from microscopic gradients that occur near the boundaries between areas displaying different magnetic susceptibility. These gradients cause dephasing of spins and frequency shifts in the surrounding tissues. Intravoxel dephasing and spatial mis-registration can degrade image quality. An aorta with a metallic stent was preserved in formaldehyde at 10% inside acrylic cylinders and used to obtain MR images. We tested pulsed spin echo and gradient echo sequences to improve image quality. All experiments were performed on a 7T/21 cm Varian system (Varian, Inc, Palo Alto, CA) equipped with Direct Drive technology and a 16-rung birdcage coil transceiver. The presence of metallic stents produces a lack of signal that might give falsely reassuring appearances within the vessel lumen.

  16. Efficacy of laser photoablative therapy and expandable metal stents for esophageal carcinoma

    Science.gov (United States)

    Balachandar, Gowra; Trowers, Eugene A.

    2000-05-01

    Malignant dysphagia is a serious condition in which 70% of patients die within one year, regardless of the treatment received. It provokes a rapid deterioration of a patient's physical condition and a significant worsening of quality of life. The surgical treatment of dysphagia is frequently complicated with technical difficulties, and often the tumors cannot be excised because of extensive invasion into adjacent structures. Furthermore, many patients are considered inoperable due to advanced age, associated diseases and malnutrition. Laser photoablative therapy coupled with expandable metal stents restores luminal patency in more than 80% of patients allowing them to eat liquids and soft foods. The efficacy of laser photoablative therapy and expandable metal stents for the palliation esophageal carcinoma will be critically reviewed.

  17. Optimal training strategies for carotid stenting.

    Science.gov (United States)

    Schneider, Peter A

    2005-06-01

    Future participation in the treatment of carotid occlusive disease is dependent on training to perform carotid stent placement. Reviewed herein are strategies for training in carotid stenting. Included in this discussion are; the skills required for carotid stenting, the carotid stent learning curve, a comparison of training and credentialing, and the roles of simulators, courses, and hands-on experience in carotid stent training.

  18. No association between metal allergy and cardiac in-stent restenosis in patients with dermatitis-results from a linkage study

    DEFF Research Database (Denmark)

    Thyssen, Jacob P; Engkilde, Kåre; Menné, Torkil

    2011-01-01

    , and it remains unclear whether individuals who are allergic to these metals have an increased risk of restenosis after PCI with stent implantation. Objectives. To further evaluate whether dermatitis patients with nickel and/or chromium allergy had an increased risk of developing cardiac in-stent restenosis...... restenosis. Conclusions. Nickel and/or chromium allergy in dermatitis patients does not appear to increase the overall risk of in-stent restenosis after PCI.......Background. Percutaneous coronary intervention (PCI) with implantation of a metal stent is a common procedure performed in patients with symptomatic ischaemic heart disease. Intracoronary stents typically have a backbone of stainless steel, which contains nickel, chromium, and molybdenum...

  19. Rationale and feasibility study of a mechanical model for the testing of material fatigue in metal ureteral stents.

    Science.gov (United States)

    Bafaloukas, Nikos; Birch, Malcom; Buchholz, Noor

    2008-02-01

    Stents are used abundantly to maintain ureteral patency. The majority are plastic tubes that adjust easily to upper urinary-tract motion. Recently, a coiled-wire lumenless stent was introduced (ZebraStent, Neo Medical, Munich, Germany) to facilitate expulsion of stone fragments after lithotripsy. Its metal core is composed of Nitinol, with the soft J ends being of titanium. The thin shape considerably increases the extraluminal space. The ZebraStent stretches the ureter and also provides a surface for the fragments to glide along. In our 18-month experience with the ZebraStent, two of them fractured along the shaft. We sought to learn whether this complication resulted from a defect in stent design or from material fatigue secondary to constant movement. Our model is powered by an electric motor that produces a constant displacement similar to stent movements in vivo. The whole ZebraStent is embedded in a 37 degrees C waterbath to simulate physiological conditions within the ureter. We used an average displacement of 16 mm. The average frequency of ventilatory-cycle simulation was 20 times that in vivo, allowing us to collect data in a shorter time. All 10 stents broke within the proximal Nitinol shaft at the equivalent of 4 to 6 months (125-179 days). Our preliminary results show that all stents break after the equivalent of 4 or more months. The fact that this occurs in the homogenous proximal Nitinol shaft rather than at the welding point between the shaft and the titanium curl implies that breakage is secondary to material fatigue and not design error. Extensive testing is under way to confirm material fatigue as the cause of breakage. We hope to determine a safe dwelling time for these stents, which at the moment should not exceed 3 months.

  20. Bronchoscopic management of critical central airway obstruction by thyroid cancer: Combination airway stenting using tracheal and inverted-Y carinal self-expanding metallic stents

    Science.gov (United States)

    Madan, Karan; Shrestha, Prajowl; Garg, Rakesh; Hadda, Vijay; Mohan, Anant; Guleria, Randeep

    2017-01-01

    Central airway obstruction (CAO) can result from various benign and malignant etiologies. Anaplastic thyroid cancer (ATC) is the most aggressive form of thyroid cancer. Rapid airway compromise is the main cause of death in ATC. We report a patient with ATC who presented with a large neck mass leading to CAO with long segment tracheal and right main bronchial compression and respiratory failure. Urgent Rigid Bronchoscopy was performed for airway stabilization and patient was managed with a combination airway stenting approach. A combination of self expanding, metallic, covered inverted Y and straight tracheal stents was used to stabilize the near complete airway structure. We herein highlight the role of therapeutic rigid bronchoscopy with airway stenting as an efficacious treatment modality for management of malignant CAO. PMID:28360477

  1. Bronchoscopic management of critical central airway obstruction by thyroid cancer: Combination airway stenting using tracheal and inverted-Y carinal self-expanding metallic stents

    Directory of Open Access Journals (Sweden)

    Karan Madan

    2017-01-01

    Full Text Available Central airway obstruction (CAO can result from various benign and malignant etiologies. Anaplastic thyroid cancer (ATC is the most aggressive form of thyroid cancer. Rapid airway compromise is the main cause of death in ATC. We report a patient with ATC who presented with a large neck mass leading to CAO with long segment tracheal and right main bronchial compression and respiratory failure. Urgent Rigid Bronchoscopy was performed for airway stabilization and patient was managed with a combination airway stenting approach. A combination of self expanding, metallic, covered inverted Y and straight tracheal stents was used to stabilize the near complete airway structure. We herein highlight the role of therapeutic rigid bronchoscopy with airway stenting as an efficacious treatment modality for management of malignant CAO.

  2. Type D personality predicts death or myocardial infarction after bare metal stent or sirolimus-eluting stent implantation

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Lemos, Pedro A; van Vooren, Priya R

    2004-01-01

    We investigated the effect of Type D personality on the occurrence of adverse events at nine months in patients with ischemic heart disease (IHD) after percutaneous coronary intervention (PCI) with sirolimus-eluting stents (SESs) or bare stents. Type D patients experience increased negative...... emotions and tend not to express these emotions in social interactions....

  3. Improved outcomes of elderly patients treated with drug-eluting versus bare metal stents in large coronary arteries

    DEFF Research Database (Denmark)

    Kurz, David J; Bernheim, Alain M; Tüller, David

    2015-01-01

    BACKGROUND: Drug-eluting stents (DES) improve outcomes in elderly patients with small coronary artery disease compared with bare-metal stents (BMS), but randomized data in elderly patients in need of large coronary stents are not available. METHODS: Planned secondary analysis of patients ≥75 years....... The primary end point was a composite of cardiac death or nonfatal myocardial infarction at 2 years. RESULTS: Comparison of DES versus BMS among 405 patients ≥75 years showed significantly lower rates of the primary end point for DES (5.0% vs 11.6%; hazard ration (HR) 0.64 [0.44-0.91]; P = .014). Rates...

  4. Comparing Percutaneous Transluminal Angioplasty and Stent Placement for Treatment of Subclavian Arterial Occlusive Disease: A Systematic Review and Meta-Analysis

    International Nuclear Information System (INIS)

    Ahmed, Ahmed T.; Mohammed, Khaled; Chehab, Monzer; Brinjikji, Waleed; Hassan Murad, M.; Cloft, Harry; Bjarnason, Haraldur

    2016-01-01

    Background and PurposeSubclavian artery occlusive disease (SAOD) is often associated with cerebrovascular symptoms such as subclavian steal syndrome and stroke. We conducted a systematic review and meta-analysis to compare percutaneous transluminal angioplasty (PTA) and stent placement for the treatment of SAOD.Materials and MethodsWe searched Medline, EMBASE, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and Scopus through October 16, 2014. From each study, we abstracted baseline patient characteristics, study design variables, and outcome data including rates of technical success, primary patency (≤2 and >2 years follow-up), symptom resolution, and complications. Meta-analysis was performed using a random-effects model.ResultsA total of 35 non-comparative studies with 1726 patients were included. Technical success rate was significantly higher in the stent group than the PTA group (92.8 vs 86.8 %, p = 0.007). Long-term primary patency rates (76.9 vs 79.6 %, p = 0.729) and symptom resolution rates (82.2 vs 73.0 %, p = 0.327) were not statistically different. There was no statistically significant difference in the rates of stroke or death.ConclusionStent placement for treatment of SAOD may be associated with higher rates of technical success but similar rates of symptom resolution and long-term outcomes. The confidence in the available estimates is low. Further comparative studies are needed to guide patients and clinicians in shared decision making.

  5. Comparing Percutaneous Transluminal Angioplasty and Stent Placement for Treatment of Subclavian Arterial Occlusive Disease: A Systematic Review and Meta-Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Ahmed T., E-mail: Ahmed.Ahmed1@mayo.edu; Mohammed, Khaled, E-mail: Mohammed.Khaled@mayo.edu [Mayo Clinic, Evidence-Based Practice Research Program (United States); Chehab, Monzer, E-mail: moe.chehab@beumont.edu [Oakland University William Beaumont School of Medicine, Department of Diagnostic Radiology and Molecular Imaging (United States); Brinjikji, Waleed, E-mail: Brinjikji.Waleed@mayo.edu [Mayo Clinic, Department of Radiology (United States); Hassan Murad, M., E-mail: Murad.Mohammad@mayo.edu [Mayo Clinic, Evidence-Based Practice Research Program (United States); Cloft, Harry, E-mail: Cloft.Harry@mayo.edu; Bjarnason, Haraldur, E-mail: Bjarnason.Haraldur@mayo.edu [Mayo Clinic, Department of Radiology (United States)

    2016-05-15

    Background and PurposeSubclavian artery occlusive disease (SAOD) is often associated with cerebrovascular symptoms such as subclavian steal syndrome and stroke. We conducted a systematic review and meta-analysis to compare percutaneous transluminal angioplasty (PTA) and stent placement for the treatment of SAOD.Materials and MethodsWe searched Medline, EMBASE, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and Scopus through October 16, 2014. From each study, we abstracted baseline patient characteristics, study design variables, and outcome data including rates of technical success, primary patency (≤2 and >2 years follow-up), symptom resolution, and complications. Meta-analysis was performed using a random-effects model.ResultsA total of 35 non-comparative studies with 1726 patients were included. Technical success rate was significantly higher in the stent group than the PTA group (92.8 vs 86.8 %, p = 0.007). Long-term primary patency rates (76.9 vs 79.6 %, p = 0.729) and symptom resolution rates (82.2 vs 73.0 %, p = 0.327) were not statistically different. There was no statistically significant difference in the rates of stroke or death.ConclusionStent placement for treatment of SAOD may be associated with higher rates of technical success but similar rates of symptom resolution and long-term outcomes. The confidence in the available estimates is low. Further comparative studies are needed to guide patients and clinicians in shared decision making.

  6. [Case in which renal function improved following stent-graft placement in the aorta two months after the onset of stanford type B acute aortic dissection].

    Science.gov (United States)

    Fusamae, Juri; Nishino, Tomoya; Uramatsu, Tadashi; Obata, Yoko; Furusu, Akira; Sakamoto, Ichiro; Kohno, Shigeru

    2011-01-01

    A 48-year-old man was admitted to the Department of Cardiovascular Surgery in our hospital after developing Stanford type B acute aortic dissection with a patent false lumen in July 2008. Conservative treatment involving rest and antihypertensive therapy was provided following admission. Urine volume decreased from day 9, and serum creatinine increased to 7.7 mg/dL. As it was suspected that the reduced renal blood flow was caused by progression of aortic dissection, contrast-enhanced computed tomography (CT)was performed. The left kidney showed reduced enhancement and the right kidney was heterogeneously enhanced. The dissection had extended to the left renal artery, and the reduced renal blood flow caused by narrowing of the left renal artery was thought to have caused the renal dysfunction. As elevated urea nitrogen and serum creatinine levels and hyperkalemia persisted, hemodialysis was performed a total of four times. Although the patient was subsequently withdrawn from dialysis, he continued to display severe renal dysfunction and was transferred to our department on day 28 for the treatment of renal failure. Conservative treatment was continued, but the maximum diameter of the thoracic aorta gradually increased, and stent placement at the entry of aortic dissection was indicated. On day 86, two stent-grafts were placed for entries at the distal site of the descending aorta and the distal site of the aortic arch. Postoperative abdominal contrast-enhanced CT showed expansion of the true lumen, and blood flow and contrast enhancement improved in both kidneys. Postoperatively, serum creatinine gradually decreased, improving to 1.16 mg/dL on day 96. Renography in the third month after stent-graft placement showed improved renal function in both kidneys. These findings suggest that even at approximately 2 months after the onset of acute renal failure associated with aortic dissection, renal function can be improved by restoring blood flow in the renal arteries.

  7. Adiponectin expression in epicardial adipose tissue after percutaneous coronary intervention with bare-metal stent.

    Science.gov (United States)

    Spener, Roberta França; Breda, João Roberto; Pires, Adilson Casemiro; Pinhal, Maria Aparecida da Silva; Souto, Ricardo Peres do

    2011-01-01

    The classical view of adipose tissue as a passive reservoir for energy storage is no longer valid. In the past decade, adipose tissue has been shown to have endocrine functions and the most abundant peptide secreted by adipocytes is adiponectin. Pericardial adipose tissue (PAT) is distributed around coronary arteries and endovascular injury, caused by the presence of intracoronary bare-metal stent (BMS), could promote inflammatory changes in the periadvential fat, contributing to vascular restenosis. We sought to determine gene expression of inflammatory mediator in pericardial adipose tissue after bare-metal stent implantation and vascular restenosis that had been referred to operative treatment. Paired samples of PAT were harvested at the time of elective coronary artery bypass surgery (CABG) in 11 patients (n = 22), one sample was obtained of the tissue around BMS area and another sample around coronary artery without stent. Local expression of adiponectin was determined by real-time polymerase chain reaction (RT-PCR) using Taq DNA polymerase. In two samples, there was no gene expression of adiponectin. We are able to identify adiponectin in 20 samples, however, the pattern of gene expression were heterogeneous.We did not notice specificity when we compared PAT obtained near BMS area or far from BMS area. There were no correlation between adiponectin gene expression and presence of BMS.

  8. Statistical parametric mapping and statistical probabilistic anatomical mapping analyses of basal/acetazolamide Tc-99m ECD brain SPECT for efficacy assessment of endovascular stent placement for middle cerebral artery stenosis

    International Nuclear Information System (INIS)

    Lee, Tae-Hong; Kim, Seong-Jang; Kim, In-Ju; Kim, Yong-Ki; Kim, Dong-Soo; Park, Kyung-Pil

    2007-01-01

    Statistical parametric mapping (SPM) and statistical probabilistic anatomical mapping (SPAM) were applied to basal/acetazolamide Tc-99m ECD brain perfusion SPECT images in patients with middle cerebral artery (MCA) stenosis to assess the efficacy of endovascular stenting of the MCA. Enrolled in the study were 11 patients (8 men and 3 women, mean age 54.2 ± 6.2 years) who had undergone endovascular stent placement for MCA stenosis. Using SPM and SPAM analyses, we compared the number of significant voxels and cerebral counts in basal and acetazolamide SPECT images before and after stenting, and assessed the perfusion changes and cerebral vascular reserve index (CVRI). The numbers of hypoperfusion voxels in SPECT images were decreased from 10,083 ± 8,326 to 4,531 ± 5,091 in basal images (P 0.0317) and from 13,398 ± 14,222 to 7,699 ± 10,199 in acetazolamide images (P = 0.0142) after MCA stenting. On SPAM analysis, the increases in cerebral counts were significant in acetazolamide images (90.9 ± 2.2 to 93.5 ± 2.3, P = 0.0098) but not in basal images (91 ± 2.7 to 92 ± 2.6, P = 0.1602). The CVRI also showed a statistically significant increase from before stenting (median 0.32; 95% CI -2.19-2.37) to after stenting (median 1.59; 95% CI -0.85-4.16; P = 0.0068). This study revealed the usefulness of voxel-based analysis of basal/acetazolamide brain perfusion SPECT after MCA stent placement. This study showed that SPM and SPAM analyses of basal/acetazolamide Tc-99m brain SPECT could be used to evaluate the short-term hemodynamic efficacy of successful MCA stent placement. (orig.)

  9. Nickel and chromium release from stents into isotonic NaCl solution investigated with the aid of neutron activation analysis

    International Nuclear Information System (INIS)

    Lin, X.; Portenlaenger, G.; Henkelmann, R.; Schulz, Ch.; Alt, E.

    1999-01-01

    Stent placement has become an effective treatment for abrupt or threatened vessel closure in recent years. As a preliminary investigation on the allergy problem towards to Ni and Cr metals from implanted stent, the release of the two elements from stents into isotonic NaCl solution was investigated. Trace amounts of Ni and Cr metals released from stents are successfully determined by neutron activation analysis (NAA). An extreme experimental condition is applied in the NAA procedure to reach a low detection limit of 1 ng Ni. A conclusion is given about the influence on the Ni and Cr release from gold coating, from the expansion, and from the different incubation periods. (author)

  10. Systemic hypersensitivity reaction to endovascular stainless steel stent.

    Science.gov (United States)

    Univers, Junior; Long, Chandler; Tonks, Stephen A; Freeman, Michael B

    2018-02-01

    Endovascular intervention has become the mainstay for treatment of most patients suffering from peripheral vascular disease. We describe a patient with a known nickel allergy who underwent placement of a stainless steel stent for aortoiliac occlusive disease. Despite our attempt to avoid a nickel-containing stent, the patient developed a diffuse rash consistent with a nickel or metal allergy. A review of stainless steel metallurgy revealed that nickel, cobalt, and titanium are frequently used to provide anticorrosive properties to stainless steel. The clinical significance of the use of nickel-alloy stents in the setting of patients with a nickel allergy is discussed. Published by Elsevier Inc.

  11. The Role of Vascular Imaging in Guiding Routine Percutaneous Coronary Interventions: A Meta-Analysis of Bare Metal Stent and Drug-Eluting Stent Trials.

    Science.gov (United States)

    Alsidawi, Said; Effat, Mohamed; Rahman, Shahid; Abdallah, Mouhamad; Leesar, Massoud

    2015-12-01

    The routine use of vascular imaging including intravascular ultrasound (IVUS) and optical coherence tomography (OCT) in guiding percutaneous coronary interventions (PCI) is still controversial especially when using drug-eluting stents. A meta-analysis of trials using bare metal stents was previously published. We conducted a meta-analysis of available published trials that compared imaging-guided PCI and angiography-guided PCI in patients undergoing routine PCI only. Trials that enrolled patients with acute coronary syndrome were excluded to decrease heterogeneity. We aimed to study both drug-eluting stents (DES) as well as bare metal stents (BMS). We identified seven randomized controlled trials on IVUS-guided bare metal stents. We also identified three randomized controlled trials on IVUS-guided drug-eluting stents. To improve the power of the drug-eluting stent data, we identified, and included, nine registries that compared IVUS-guided PCI to angiography-guided PCI in the drug-eluting stent era. Nonrandomized registries that included BMS only were excluded as there are multiple previous meta-analyses that studied these patients. Finally, we identified one registry that compared OCT-guided PCI to angiography-guided PCI using either a BMS or a DES. A total of 14,197 patients were studied overall. The meta-analysis was conducted using a random effect model. Imaging guidance was associated with a significantly larger postintervention minimal luminal diameter (SMD: 0.289. 95% CI: 0.213-0.365. P DES patients (odds ratio: 0.810. 95% CI: 0.719-0.912. P DES and BMS patients (odds ratio: 0.782. 95% CI: 0.686-0.890. P DES patients (odds ratio: 0.654. 95% CI: 0.468-0.916. P DES and BMS patients (odds ratio: 0.727. 95% CI: 0.540-0.980. P DES patients (odds ratio: 0.551. 95% CI: 0.363-0.837. P DES and BMS patients (odds ratio: 0.589. 95% CI: 0.425-0.816. P DES patients (odds ratio: 0.651. 95% CI: 0.499-0.850. P DES and BMS patients (odds ratio: 0.665. 95% CI: 0.513-0.862. P

  12. What is the ideal stent as initial intervention for malignant gastric outlet obstruction?

    Science.gov (United States)

    Park, Chan Ik; Kim, Jie-Hyun; Lee, Yong Chan; Jahng, Jaehoon; Youn, Young Hoon; Park, Hyojin; Lee, Sang In

    2013-01-01

    Self-expandable metal stents are effective palliation for malignant gastric outlet obstruction. The aims of study were to evaluate efficacy and safety of double-layered Comvi, uncovered and covered stent to find out protocols which enhance stent patency. We retrospectively analysed data from 224 patients who underwent endoscopic stent placement for malignant gastric outlet obstruction caused by stomach cancer from 2006 to 2011. Technical and clinical success rates were evaluated and clinical outcomes were compared according to stent types and chemotherapy. The overall technical and clinical success rates were achieved in 99.6% and 80.4%, respectively without immediate complications. The clinical success rate was not significantly different between three groups. The median stent patency time was 156 days [interquartile range 66-279] without differences between groups. The 4-, 8-, and 12-week patency rates were 89.4%, 77.3%, and 61.2%, respectively with no differences between groups. The re-stenosis of stent frequently occurred in the case of the uncovered stents, while migration was more likely to be observed for the covered and Comvi stent. Chemotherapy significantly lowered re-intervention rates, especially in uncovered stents. Patency rates are significantly improved by combining the use of uncovered stent with follow-up chemotherapy treatment, which retains the advantages of the mechanical and chemical aspects of stent and chemotherapy, respectively. Copyright © 2012 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  13. Outcome of self-expanding metal stenting followed by radiation therapy for unresectable extrahepatic bile duct cancer

    International Nuclear Information System (INIS)

    Jin Jing; Gao Li; Yu Zihao; Han Jianzhu; Zhai Renyou

    2007-01-01

    Objective: To retrospectively analyze the efficacy for self-expanding metal stenting followed by radiation therapy for unresectable extrahepatic bile duct cancer. Methods: From Jan 1996 to Sep 2002, 17 patients were treated with self-expanding metal stenting followed by Ir 192 high dose brachytherapy (brachytherapy group, n=5)and by external beam radiation therapy(external radiation therapy group, n=9). Brachytherapy was delivered on the same day or the following day after stenting with the total dose of DT 20- 30 Gy, twice daily, for 2-3 days. The median total dosage of external radiation therapy was 48 Gy (14-66 Gy), 2 Gy/fraction. Results: Jaundice was released after metal stenting from 71.4% to 14.3% (P=0.001), showing no significant difference between brachytherapy and external radiation therapy in terms of jaundice release(χ 2 =0.21, P=0.65). The median survival period(5-35 months)for whole groups was 12 months 1-, 2-year survival rates were 40.8% and 8.16%, respectively. No significant difference was shown for patients received either brachytherapy or external radiation therapy for 8 months, but with 1,2 year survival rate as 40.0%, 13.3%, respectively (χ 2 =1.10, P=0.29). Conclusions: Self-expanding metal stenting is able to release jaundice significantly and followed by high dose radiation therapy may further prolong the survival. (authors)

  14. Long-term Outcomes of Drug-eluting versus Bare-metal stent for ST-elevation Myocardial Infarction

    Directory of Open Access Journals (Sweden)

    Liping Wang

    2014-06-01

    Full Text Available Background: Long-term outcomes of drug-eluting stents (DES versus bare-metal stents (BMS in patients with ST-segment elevation myocardial infarction (STEMI remain uncertain. Objective: To investigate long-term outcomes of drug-eluting stents (DES versus bare-metal stents (BMS in patients with ST-segment elevation myocardial infarction (STEMI. Methods: We performed search of MEDLINE, EMBASE, the Cochrane library, and ISI Web of Science (until February 2013 for randomized trials comparing more than 12-month efficacy or safety of DES with BMS in patients with STEMI. Pooled estimate was presented with risk ratio (RR and its 95% confidence interval (CI using random-effects model. Results: Ten trials with 7,592 participants with STEMI were included. The overall results showed that there was no significant difference in the incidence of all-cause death and definite/probable stent thrombosis between DES and BMS at long-term follow-up. Patients receiving DES implantation appeared to have a lower 1-year incidence of recurrent myocardial infarction than those receiving BMS (RR = 0.75, 95% CI 0.56 to 1.00, p= 0.05. Moreover, the risk of target vessel revascularization (TVR after receiving DES was consistently lowered during long-term observation (all p< 0.01. In subgroup analysis, the use of everolimus-eluting stents (EES was associated with reduced risk of stent thrombosis in STEMI patients (RR = 0.37, p=0.02. Conclusions: DES did not increase the risk of stent thrombosis in patients with STEMI compared with BMS. Moreover, the use of DES did lower long-term risk of repeat revascularization and might decrease the occurrence of reinfarction.

  15. Primary Stent Placement of an Acute Occlusion in the Iliac Arteries of Patients with Acute Limb Ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Ki Chan; Shin, Tae Beom; Choi, Ho Cheol; Choi, Hye Young; Kim, Ji Eun; Chung, Sung Hoon [Gyeongsang National University Hospital, Jinju (Korea, Republic of)

    2009-01-15

    To assess the efficacy of stent-assisted recanalization for the management of acute limb ischemia (ALI) after a failed surgical revascularization in patients with acute iliac arterial occlusion and considered unfit for a thrombolysis. The data on 6 patients with acute limb ischemia due to iliac arterial occlusion, and treated with stent implantation between November 2005 and March 2008, was analyzed retrospectively. The reasons for ALI in the patients analyzed included acute thrombosis related to a traumatic injury (n=3), acute in-situ thrombosis with pre-existing atherosclerotic stenosis (n=2), and cardiogenic embolism (n=1). A preprocedural CT angiography and conventional angiography revealed an occlusion at the iliac artery. This study examined the clinical data, technical and clinical outcome of the procedure, and complications related to the procedure or follow-up period for each patient. Primary stenting was technically successful in all patients, thus resulting in the reduction or elimination of clinical symptoms in the 5 patients observed. One patient expired due to multi-organ failure related to a reperfusion injury. The other five patients showed good clinical results without symptom recurrence and normal duplex USG or CT angiographic findings during the 3-15 month follow-up period. A stent-assisted recanalization is an effective treatment for patients with ALI, which are considered unfit for thrombolysis and surgical recanalization.

  16. Late Migration of Two Covered Biliary Stents Through a Spontaneous Bilioenteric Fistula in a Patient with Malignant Biliary Obstruction

    International Nuclear Information System (INIS)

    Krokidis, Miltiadis E.; Hatzidakis, Adam A.; Manousaki, Eirini G.; Gourtsoyiannis, Nicholas C.

    2008-01-01

    We report a case of simultaneous late migration of two ePTFE-FEP covered biliary endoprostheses (Viabil, W.L. Gore, Flagstaff, AZ, USA) that were percutaneously implanted for the treatment of malignant obstructive jaundice. The first Viabil covered stent was placed successfully without any evidence of dislocation or other complication during follow-up. Occlusion of the stent occurred 4 months later and was treated with the placement of a second stent of the same type. Thirteen months later the patient became symptomatic. Percutaneous transhepatic cholangiography (PTC) revealed the presence of a choledocho-duodenal fistula and the disappearance of the two endoprostheses previously implanted. A third metallic stent was then percutaneously positioned through the bilioenteric fistula. The computed tomography scan that followed for the detection of the metallic bodies did not reveal the dislocated metallic stents. Stent migration is a well-known complication of uncovered metallic stents, though Viabil stent migration is assumed to be most unlikely to happen due to the stent's anchoring barbs. Furthermore, the stent had already been tightly fixed by tumor over- and ingrowth, as recognized in previous imaging. This is a very unusual case, describing the disappearance of two metallic foreign bodies encapsulated by tumor

  17. A true bifurcational stenosis treated with a bioresorbable vascular scaffold and a drug-eluting metallic stent: Degradable meets durable.

    Science.gov (United States)

    Wiebe, Jens; Hamm, Christian; Nef, Holger

    2015-06-01

    The role of bioresorbable scaffolds (BRS) has mostly been investigated in simple coronary lesions. True bifurcational stenoses are one of the major challenges in interventional cardiology. We report here a successful case of a hybrid approach using a bioresorbable scaffold and a drug-eluting metallic stent to treat a true bifurcational lesion. Due to the degradable character of the BRS, only one metallic stent remains and thus the risk of restenosis can possibly be reduced. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  18. Clinical outcomes of re-stenting in patients with stent malfunction in malignant gastric outlet obstruction.

    Science.gov (United States)

    Jin, Eun Hyo; Kim, Sang Gyun; Seo, Ji Yeon; Im, Jong Pil; Kim, Joo Sung; Jung, Hyun Chae

    2016-04-01

    Self-expanding metal stents (SEMS) have been used for the palliative treatment of malignant gastric outlet obstruction (GOO). The aim of this study was to evaluate the clinical outcomes of salvage SEMS for stent malfunction and to identify the prognostic factors for a longer patency. A total of 108 patients who underwent a secondary salvage SEMS placement for a primary stent malfunction were retrospectively reviewed at the Seoul National University Hospital between August 2004 and May 2013. The duration of patency for salvage SEMS was defined as the time between salvage SEMS placement and the recurrence of obstructive symptoms that were confirmed either endoscopically or radiologically. The technical and clinical success rates for salvage SEMS were 100 and 82.4% (95% confidence interval [CI] 74.0-89.0), respectively. A salvage SEMS malfunction occurred in 29 (26.9%) of the 108 patients. The median duration of patency for salvage SEMS was 59.5 days (range 3-928, 95% CI 73.7-118.3). Longer SEMS patencies of more than 60 days were significantly associated with palliative chemotherapy (odds ratio = 2.539, 95% CI 1.031-6.252, p = .043). For salvage SEMS, covered-uncovered stents had a longer patency duration, as compared with other combinations of primary and salvage stent types. Longer patency durations for salvage SEMS were associated with palliative chemotherapy after salvage SEMS insertion. Salvage SEMS could be a feasible and effective treatment for primary stent malfunction in malignant GOO.

  19. Emergent intracranial balloon angioplasty and bailout self-expandable stent placement in acute large vessel occlusion of the anterior circulation: Experience of a single institution

    International Nuclear Information System (INIS)

    Heo, Young Jin; Seo, Jung Hwa; Jeong, Hae Woong

    2017-01-01

    To evaluate the outcomes of angioplasty for recanalization after acute ischemic stroke (AIS). The study population was selected from 134 patients who underwent endovascular revascularization therapy (ERT) for AIS between October 2011 and May 2014. Of those 134 patients, 39 who underwent balloon angioplasty with or without stent insertion were included in this study. Balloon angioplasty was the primary treatment for nine patients and a rescue method for 30 patients. The revascularization rate at 7 days, procedure-related complications, and clinical outcomes at 3 months were analyzed. The occlusion sites were the middle cerebral artery (n = 26), intracranial internal carotid artery (n = 10), and middle cerebral artery branch (n = 3). Angioplasty achieved successful revascularization (Thrombolysis in Cerebral Ischemia grade 2b–3) in 76.9% of patients. Computed tomography angiography performed 7 days post-procedure revealed a maintained reperfusion in 82.8% of successful cases. Only two patients had symptomatic intracerebral hemorrhage. At the 3-month follow-up, 18 (48.6%) and 10 (27.0%) patients showed good and poor functional outcomes, respectively (modified Rankin Scale scores, 0–2 and 5–6). Emergent balloon angioplasty and bailout self-expandable stent placement may be safe and effective for achieving successful revascularization in acute large vessel occlusion of the anterior circulation. It could be a feasible rescue method as well as a primary method for ERT

  20. Emergent intracranial balloon angioplasty and bailout self-expandable stent placement in acute large vessel occlusion of the anterior circulation: Experience of a single institution

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Young Jin; Seo, Jung Hwa; Jeong, Hae Woong [Busan Paik Hospital, Inje University, Busan (Korea, Republic of)

    2017-06-15

    To evaluate the outcomes of angioplasty for recanalization after acute ischemic stroke (AIS). The study population was selected from 134 patients who underwent endovascular revascularization therapy (ERT) for AIS between October 2011 and May 2014. Of those 134 patients, 39 who underwent balloon angioplasty with or without stent insertion were included in this study. Balloon angioplasty was the primary treatment for nine patients and a rescue method for 30 patients. The revascularization rate at 7 days, procedure-related complications, and clinical outcomes at 3 months were analyzed. The occlusion sites were the middle cerebral artery (n = 26), intracranial internal carotid artery (n = 10), and middle cerebral artery branch (n = 3). Angioplasty achieved successful revascularization (Thrombolysis in Cerebral Ischemia grade 2b–3) in 76.9% of patients. Computed tomography angiography performed 7 days post-procedure revealed a maintained reperfusion in 82.8% of successful cases. Only two patients had symptomatic intracerebral hemorrhage. At the 3-month follow-up, 18 (48.6%) and 10 (27.0%) patients showed good and poor functional outcomes, respectively (modified Rankin Scale scores, 0–2 and 5–6). Emergent balloon angioplasty and bailout self-expandable stent placement may be safe and effective for achieving successful revascularization in acute large vessel occlusion of the anterior circulation. It could be a feasible rescue method as well as a primary method for ERT.

  1. Self-expandable medical memorial metallic stent with 125I seeds for the treatment of esophageal carcinoma: a retrospective analysis

    International Nuclear Information System (INIS)

    Zhang Shuo; Lu Bin

    2011-01-01

    Objective: To discuss the curative effect and safety of the implantation of self-expandable medical memorial metallic stent with 125 I seeds for the treatment of advanced esophageal carcinomas. Methods: Implantation of self-expandable medical memorial metallic stent with 125 I seeds was performed in 32 patients with advanced esophageal canner. The clinical data were retrospectively analyzed. The technical success rate, the operation time, the immediate and mid-term effectiveness, the survival time, the complications, the body weight, the blood picture, the immune indexes, the average hospitalization days and hospitalization expenses were analyzed. Results: The average operation time was (18±5) minutes. Successful stent implantation was achieved in all 32 patients (100%). No 125 I seeds fell off during the procedure. The remission rate of dysphagia was 100%. Esophageal restenosis occurred in four patients, and displacement of the stent was seed in one patient. One month after the treatment, 90% of patients had a Karnofsky performance score over 60. The mean survival time was (8.7±6.6) months. The average hospitalization time was (7.8±3.7) days and the mean hospitalization cost was (12±3) thousand Chinese Yuan. Conclusion: For the treatment of esophageal carcinomas, the implantation of self-expandable medical memorial metallic stent with 125 I seeds is safe, effective and simple. This treatment can markedly improve the symptom of dysphagia and significantly prolong the patient's survival time. (authors)

  2. Mechanical behavior of polymer-basedvs. metallic-based bioresorbable stents.

    Science.gov (United States)

    Ang, Hui Ying; Huang, Ying Ying; Lim, Soo Teik; Wong, Philip; Joner, Michael; Foin, Nicolas

    2017-08-01

    Bioresorbable scaffolds (BRS) were developed to overcome the drawbacks of current metallic drug-eluting stents (DES), such as late in-stent restenosis and caging of the vessel permanently. The concept of the BRS is to provide transient support to the vessel during healing before being degraded and resorbed by the body, freeing the vessel and restoring vasomotion. The mechanical properties of the BRS are influenced by the choice of the material and processing methods. Due to insufficient radial strength of the bioresorbable material, BRS often required large strut profile as compared to conventional metallic DES. Having thick struts will in turn affect the deliverability of the device and may cause flow disturbance, thereby increasing the incidence of acute thrombotic events. Currently, the bioresorbable poly-l-lactic acid (PLLA) polymer and magnesium (Mg) alloys are being investigated as materials in BRS technologies. The bioresorption process, mechanical properties, in vitro observations and clinical outcomes of PLLA-based and Mg-based BRS will be examined in this review.

  3. SU-E-T-115: Dose Perturbation Study of Self-Expandable Metal and Polyester Esophageal Stents in Proton Therapy Beams

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S; Li, Z [University of Florida Proton Therapy Institute, Jacksonville, FL (United States); Jalaj, S; McGaw, C; B K, John; J S, Scolapio; J C, Munoz [Division of Gastoenterology, Department of Medicine, University of Florida, Jacksonville, FL (United States)

    2014-06-01

    Purpose: This work investigates dose perturbations due to Self-expandable metal and polyester esophageal stents undergoing proton radiotherapy for esophageal cancer. Methods: Five commercially available esophageal stents made of nitinol (Evolution, Wallflex and Ultraflex), stainless steel (Z-Stent) and polyester (Polyflex) were tested. Radiochromic film (GafChromic EBT3 film, Ashland, Covington, KY) wrapped around a stent and a 12cc syringe was irradiated with 2CGE (Cobalt Gray Equivalent) of proton beam in a custom fabricated acrylic phantom. An air-hollow syringe simulates the esophagus. Results: The Z-stent created the largest dose perturbations ranges from -14.5% to 6.1% due to the steel composition. The WallFlex, Evolution and Ultraflex stents produced the dose perturbation ranges of (−9.2%∼8.6%), (−6.8%∼5.7%) and (−6.2%∼6.2%), respectively. The PolyFlex stent contains the radiopaque tungsten markers located top, middle and bottom portions. When the focal cold spots induced by the markers were excluded in the analysis, the dose perturbation range was changed from (−11.6%∼6.4%) to (−0.6%∼5.0%). Conclusion: The magnitude of dose perturbation is related to material of a metallic stent. The non-metallic stent such as PolyFlex shows relatively lower dose perturbation than metallic stents except a radiopaque marker region. Overall Evolution and Ultraflex stent appear to be less dose perturbations. The largest dose perturbations (cold spots) were located at both edges of stents in distal area for the single proton beam irradiation study. The analysis of more than two proton beam which is more typical clinical beam arrangement would be necessary to minimize the doe perturbation effect in proton ratiotherapy.

  4. Stent thrombosis caused by metal allergy complicated by protein S deficiency and heparin-induced thrombocytopenia: a case report and review of the literature

    OpenAIRE

    Konishi, Takao; Yamamoto, Tadashi; Funayama, Naohiro; Yamaguchi, Beni; Sakurai, Seiichiro; Nishihara, Hiroshi; Yamazaki, Koko; Kashiwagi, Yusuke; Sasa, Yasuki; Gima, Mitsuru; Tanaka, Hideichi; Hotta, Daisuke; Kikuchi, Kenjiro

    2015-01-01

    A 43-year-old woman recipient of a bare metal coronary stent during an acute anterior myocardial infarction was repeatedly hospitalized with recurrent stent thrombosis (ST) over the following 3?years. Emergent coronary angiography showed a thrombus in the in-stent segment of the proximal left anterior descending artery. We repeatedly aspirated the thrombus, which immediately reformed multiple times. The discontinuation of heparin and administration of thrombolytics and argatroban, followed by...

  5. Results of Stent Graft Placement to Treat Cephalic Arch Stenosis in Hemodialysis Patients with Dysfunctional Brachiocephalic Arteriovenous Fistulas.

    Science.gov (United States)

    Jones, Robert G; Willis, Andrew P; Tullett, Karen; Riley, Peter L

    2017-10-01

    To determine effectiveness of the VIABAHN (W.L. Gore & Associates, Flagstaff, Arizona) stent graft to treat cephalic arch stenosis in patients with dysfunctional brachiocephalic arteriovenous fistulas after inadequate venoplasty response. Between 2012 and 2015, patients with failed venoplasty of symptomatic cephalic arch stenosis received a VIABAHN stent graft. Follow-up venography was performed at approximately 3, 6, and 12 months. Data were retrospectively analyzed with patency estimated using Kaplan-Meier and log-rank methodology. There were 39 patients included. Technical and clinical success was 100%. Primary target lesion patency was 85% (95% confidence interval [CI], 69%-93%), 67% (95% CI, 50%-80%), and 42% (95% CI, 25%-57%) at 3, 6, and 12 months. There was no significant difference in patency with regard to sex or age (P = .8 and P = .6, respectively). Primary assisted patency was 95% (95% CI, 82%-99%) at 3, 6, and 12 months. Access circuit primary patency was 85% (95% CI, 69%-93%), 67% (95% CI, 50%-80%), and 42% (95% CI, 25%-57%) at 3, 6, and 12 months. There was no significant difference in patency between patients with the stent graft as the first treatment episode in the cephalic arch and those that had previous intervention at this site (P = .98). There were 48 repeat venoplasty procedures performed in the cephalic arch to maintain patency, including 7 repeat VIABAHN insertions. No complications were encountered. The VIABAHN stent graft is a safe, effective, and durable device for treating cephalic arch stenosis when venoplasty fails. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  6. Drug-eluting stents for coronary bifurcations: bench testing of provisional side-branch strategies.

    Science.gov (United States)

    Ormiston, John A; Webster, Mark W I; El Jack, Seifeddin; Ruygrok, Peter N; Stewart, James T; Scott, Douglas; Currie, Erin; Panther, Monique J; Shaw, Bronwyn; O'Shaughnessy, Barbara

    2006-01-01

    The objective of this study was to bench-test provisional bifurcation stenting strategies to provide insights on how best to perform these with drug-eluting stents (DESs). Bifurcation stenting with DESs reduces restenosis compared with bare metal stents (BMSs). Outcomes with a single DES are better than with two DESs but if the main branch is stented, there needs to be a reliable strategy for provisionally stenting the side-branch with full ostial scaffolding and drug application. Stents were photographed in a phantom after deployment with different strategies. With provisional T-stenting, placement of the side-branch stent without gaps is difficult. The internal (or reverse) crush strategy fully scaffolds the side-branch ostium but is experimental. The culotte technique providing excellent side-branch ostial coverage is easier to perform with open-cell or large-cell stent design. In general, kissing balloon post-dilation improves stent expansion, especially at the ostium, and corrects distortion. However, a main-branch kissing balloon of smaller diameter than the deploying balloon causes distortion. Final main-branch postdilatation or sequential postdilatation prevents distortion after the internal crush strategy.

  7. Delayed Migration of a WallFlex Enteral Stent Resulting in Jejunal Perforation

    Directory of Open Access Journals (Sweden)

    Phillip S. Ge

    2013-01-01

    Full Text Available Enteral stents are increasingly utilized to palliate malignant gastrointestinal obstruction; however, they can be associated with significant complications. We describe an unusual case of a 67-year-old male with gastric adenocarcinoma who underwent placement of a WallFlex metallic enteral stent to relieve a malignant gastric outlet obstruction. Four months later, while actively undergoing chemotherapy, he developed acute abdominal pain and was found to have delayed stent migration and jejunal perforation. He required emergent surgical resection of the perforated segment of jejunum. Delayed migration of the WallFlex enteral stent with subsequent visceral perforation has yet to be reported in the literature. Chemotherapy after stent placement has been associated with an increase in maintenance of stent patency; however, shrinkage of the local tumor by chemoradiation may increase the risk of stent migration. Care should be taken in placing enteral stents in patients undergoing continued treatment of their malignancy, as delayed migration of even uncovered stents may occur.

  8. Modified gianturco biliary stent in benign and malignant obstruction: Results of long-term follow up

    International Nuclear Information System (INIS)

    Chung, Jin Young; Song, Ho Young; Han, Hyun Young; Han, Young Min; Chung, Gyung Ho; Kim, Chong Soo; Choi, Ki Chul; Roh, Byung Suk; Kim, Jae Kyu

    1993-01-01

    Modified biliary gianturco stents were placed in 27 patients with obstructive jaundice. From July 1990 to October 1992, 46 two-seven connected stents of 8-12 mm in diameter (Myungsung Meditech, Seoul, Korea) were placed in 5 patients with benign biliary stricture and 22 patients with malignant biliary stricture in three university hospitals; 12 in Chonbuk National University Hospital, 12 in Wonkwang University Hospital, and 3 in Chonnam National University Hospital. Nineteen were men and eight were women, ranged in age from 34 to 76 years (average, 55 years). The stents were placed percutaneously through a transhepatic approach using a 8.5 Fr. introducing sheath. All stents were placed successfully without any technical failures or procedural morbidity or mortality. All patients complained dull abdominal pain for 1 to 3 days after the stent placement. In a follow-up period of 7-46 weeks, reocclusions were observed in one of the patients with benign stricture (20%) and three of the patients with malignant stricture (16%). Two patients with recurrent jaundice due to the obstruction of the stent were treated with placement of additional stent, one patient was treated with external catheter drainage. Migration of stent occurred in one patient. The application of the expandable biliary metallic stent is suggested as an effective treatment for benign and malignant biliary obstructive jaundice

  9. Comparison of Drug-Eluting Stent with Bare-Metal Stent Implantation in Femoropopliteal Artery Disease: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Ding, Yong; Zhou, Min; Wang, Yonggang; Cai, Liang; Shi, Zhenyu

    2018-03-04

    This study aimed to perform a systematic review and meta-analysis of current evidence comparing the drug-eluting stent (DES) with the bare-metal stent (BMS) in the treatment of femoropopliteal artery disease (FPAD). All relevant articles reporting the results of DES versus BMS implantation in FPAD were systematically searched in MEDLINE, EMBASE, and Cochrane database. Randomized controlled trial, cohort, and retrospective study were all included. The efficacy endpoints included late lumen loss, binary restenosis, primary patency rate, freedom from target lesion revascularization, and stent fracture. Related data of the follow-up outcomes were extracted and pooled. For each endpoint, odds ratios (ORs) and 95% confidence intervals (CIs) were calculated. A total of 9 studies with 776 patients were included in this meta-analysis. There was no statistically significant difference between the DES and BMS groups in terms of late lumen loss at 6 months (SMD = -0.37, P = 0.07); binary restenosis at 6, 12, and 24 months (OR = 0.44, P = 0.20; OR = 0.75, P = 0.74; OR = 0.62, P = 0.36; respectively); primary patency rate at 6, 12, and 24 months (OR = 1.18, P = 0.73; OR = 1.43, P = 0.70; OR = 1.25, P = 0.68, respectively); freedom from target lesion revascularization at 12 months (OR = 1.13, P = 0.79); and stent fracture at 6 months (OR = 1.67, P = 0.38). A sensitivity analysis demonstrated that there was a significant benefit in the DES group over the BMS group in binary restenosis at 6 months (OR = 0.22, P = 0.008) after excluding a retrospective study, whereas no significant difference was observed when eliminating any other study. A subgroup analysis did not reveal any significant difference between a subgroup (sirolimus-eluting stent or paclitaxel-eluting stent) and the BMS group in FPAD. According to current evidence, DES was not superior to BMS in the treatment of FPAD. Further larger randomized controlled trials are needed to provide more evidence in the comparison

  10. The location of obstruction predicts stent occlusion in malignant gastric outlet obstruction

    Science.gov (United States)

    Grunwald, Douglas; Cohen, Jonah; Bartley, Anthony; Sheridan, Jennifer; Chuttani, Ram; Sawhney, Mandeep S.; Pleskow, Douglas K.; Berzin, Tyler M.; Mizrahi, Meir

    2016-01-01

    Background: Gastric outlet obstruction (GOO) can occur with locally invasive or metastatic cancer involving the upper gastrointestinal tract at the pylorus or the duodenum. Endoscopic management with self-expanding metal stents (SEMSs) is often the preferred palliative approach. Stent occlusion is a common reason for failure and reintervention. We set out to determine whether the location of the malignant obstruction is associated with the angulation of the stent and can predict stent occlusion. Methods: We performed a retrospective review of consecutive patients who underwent successful duodenal stenting with SEMS for malignant GOO between 2006 and 2015 at a large advanced endoscopy referral center. We determined the location of obstruction, the stent angle, and the rate of technical and clinical success of stent placement. We then identified cases of subsequent stent occlusion confirmed by endoscopic evaluation. Results: A total of 100 consecutive patients were included in the study; 91 of these patients had enough data to evaluate SEMS occlusion. A total of 21 patients (23%) developed stent occlusion with a median time of 39 days. The risk of occlusion sequentially increased as the obstruction occurred more distally from the antrum to the third or fourth portion of the duodenum (p = 0.006). This relationship was maintained after controlling for stent angle (p = 0.05). Conclusions: A distal location of malignant GOO was strongly predictive of stent occlusion, independent of stent angle. This may be due to longer and more complex distal obstructions, along with foreshortening of the stent during placement and tumor infiltration. If replicated, these results will have implications for endoscopic practice and future device development. PMID:27803736

  11. Comparison of Drug-Eluting Stents With Bare-Metal Stents for PCI of Saphenous Vein Graft Lesions: Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Mosleh, Wassim; Gandhi, Sumeet; Elsiddig, Mohamed; Schwalm, Jon-David; Farkouh, Michael E

    2016-12-01

    The superiority of drug-eluting stent (DES) implantation over bare-metal stent (BMS) implantation in saphenous vein graft (SVG) lesions is controversial, with significant heterogeneity demonstrated in the literature. A study search was conducted from January 2003 to October 2015, and identified four randomized controlled trials (RCTs) and 35 observational studies comparing DES vs BMS in SVG interventions. Clinical endpoint data were abstracted and analyzed by combining the odds ratios (ORs) of individual studies into a pooled OR using a random-effects model. The meta-analysis included 39,213 patients in the DES group and 26,461 patients in the BMS group. Patients who underwent percutaneous coronary intervention with DES had lower major adverse cardiovascular event (MACE) rate (OR, 0.63; 95% confidence interval [CI], 0.54-0.74; PDES group compared with the BMS group (OR, 0.87; 95% CI, 0.73-1.04; P=.13). Benefits were sustained at long-term follow-up of 36 months without an increased risk of early and/or late stent thrombosis. The observed benefit for MACE was only seen in observational studies (OR, 0.63; 95% CI, 0.53-0.75; PDES in comparison with BMS implantation for PCI to SVG lesions had lower MACE, all-cause mortality, and TVR rates, without a significant reduction in MI and TLR.

  12. No association between metal allergy and cardiac in-stent restenosis in patients with dermatitis-results from a linkage study.

    Science.gov (United States)

    Thyssen, Jacob P; Engkilde, Kåre; Menné, Torkil; Johansen, Jeanne D; Hansen, Peter Riis; Gislason, Gunnar H

    2011-03-01

    Percutaneous coronary intervention (PCI) with implantation of a metal stent is a common procedure performed in patients with symptomatic ischaemic heart disease. Intracoronary stents typically have a backbone of stainless steel, which contains nickel, chromium, and molybdenum, and it remains unclear whether individuals who are allergic to these metals have an increased risk of restenosis after PCI with stent implantation. To further evaluate whether dermatitis patients with nickel and/or chromium allergy had an increased risk of developing cardiac in-stent restenosis with stainless steel stents. An individual-level linkage study was performed to identify dermatitis patients who had been patch tested with the European baseline series between 1979 and 2007 at Gentofte University Hospital (N = 18794) and who had also undergone PCI at some point in a Danish hospital. One hundred and forty-nine (0.8%) dermatitis patients who had undergone PCI with a metal stent were included. One hundred and forty-seven were patch-tested before undergoing PCI. Of the patients, 14.1% (21/149) had cardiac in-stent restenosis. Among patients with metal allergy, 2 (11.8%) had restenosis. Nickel and/or chromium allergy in dermatitis patients does not appear to increase the overall risk of in-stent restenosis after PCI. © 2011 John Wiley & Sons A/S.

  13. Budd-Chiari syndrome due to prothrombotic disorder: mid-term patency and efficacy of endovascular stents

    Energy Technology Data Exchange (ETDEWEB)

    Pelage, Jean-Pierre; Denys, Alban; Sibert, Annie; Menu, Yves [Department of Radiology, Hopital Beaujon, AP-HP, 100 Boulevard du General Leclerc, 92110 Clichy (France); Valla, Dominique [Department of Hepatology, Hopital Beaujon, AP-HP, 100 Boulevard du General Leclerc, 92110 Clichy (France); Sauvanet, Alain; Belghiti, Jacques [Department of Surgery, Hopital Beaujon, AP-HP, 100 Boulevard du General Leclerc, 92110 Clichy (France)

    2003-02-01

    Our objective was to evaluate efficacy and patency of metallic stent placement for symptomatic Budd-Chiari syndrome (BCS) due to prothrombotic disorders. Eleven patients with proved BCS due to prothrombotic disorders were referred for endovascular treatment because of refractory ascites (n=9), abdominal pain (n=8), jaundice (n=6), and/or gastrointestinal bleeding (n=4). Stents were inserted for stenosed hepatic vein (n=7), inferior vena cava (n=2), or mesenterico-caval shunt (n=2). Clinical efficacy and stent patency was evaluated by clinical and Doppler follow-up. After a mean follow-up of 21 months, 6 patients had fully patent stents without reintervention (primary stent patency: 55%). Two patients with hepatic vein stenosis had stent thrombosis and died 4 months after procedure. Restenosis occurred in 3 cases (2 hepatic vein and 1 mesenterico-caval shunt stenosis) and were successfully treated by balloon angioplasty (n=2) and addition of new stents (n=1) leading to a 82% secondary stent patency. Of 9 patients with patent stent, 7 were asymptomatic (77%) at the end of the study. Stent placement is a safe and effective procedure to control of symptomatic BCS. Prothrombotic disorder does not seem to jeopardize patency in anticoagulated patients. (orig.)

  14. Comparison of plain balloon and cutting balloon angioplasty for the treatment of restenosis with drug-eluting stents vs bare metal stents.

    Science.gov (United States)

    Park, Seung-Jung; Kim, Kyung-Hee; Oh, Il-Young; Shin, Dong-Ho; Park, Kyung-Il; Seo, Myung-Ki; Chung, Jin-Wook; Park, Kyung Woo; Lee, Hae-Young; Kang, Hyun-Jae; Koo, Bon-Kwon; Youn, Tae-Jin; Kim, Hyo-Soo

    2010-09-01

    The efficacy of cutting or plain balloon angioplasty (CBA or PBA) has not been analyzed for the treatment of drug-eluting stent (DES) restenosis vs bare metal stent (BMS) restenosis. The 252 in-stent restenosis (ISR) lesions in 224 consecutive patients treated by CBA (n=167) or PBA (n=85) between July 2002 and December 2007 were analyzed. At 6-month angiographic and 12-month clinical follow-up, CBA and PBA showed similar efficacies: repeat-ISR (37.0% vs 37.8%, P=0.90), late loss (0.62+/-0.60 vs 0.61+/-0.47 mm, P=0.92), and target lesion revascularization (18.3% vs 22.4%, P=0.50). This comparable efficacy was maintained for treatment in the DES-ISR and BMS-ISR subgroups. However, target lesion-related myocardial infarction (n=9) occurred more frequently in the CBA than in the PBA arm (6.2% vs 0%, P=0.03), most of which developed early after ISR treatment (n=7; 54+/-26 days). Independent predictors of repeat-ISR were diffuse ISR and smaller pretreatment minimal lumen diameter, both of which might imply heavier plaque burden in the ISR group. Plain or cutting balloon angioplasty for ISR seems to be comparable, as the angiographic or clinical endpoints were not affected by initial stent type but by parameters related to the plaque burden of the ISR lesion. However, CBA might be associated with higher risk of myocardial infarction than PBA, suggesting more attention to dual-antiplatelet therapy after its use for ISR.

  15. Impact of cutting balloon angioplasty (CBA) prior to bare metal stenting on restenosis.

    Science.gov (United States)

    Ozaki, Yukio; Yamaguchi, Tetsu; Suzuki, Takahiko; Nakamura, Masato; Kitayama, Michihiko; Nishikawa, Hideo; Inoue, Teruo; Hara, Kazuhiro; Usuba, Fumihiko; Sakurada, Masami; Awano, Kojiro; Matsuo, Hitoshi; Ishiwata, Sugao; Yasukawa, Tatsuya; Ismail, Tevfik F; Hishida, Hitoshi; Kato, Osamu

    2007-01-01

    While stent restenosis and late thrombosis still occur even with drug-eluting-stents (DES), there remains a need to explore other strategies for preventing restenosis. Five hundred and twenty-one patients were randomized: 260 to cutting-balloon angioplasty (CBA) before bare-metal stent (CBA-BMS) and 261 to balloon-angioplasty (BA) before BMS (BA-BMS). Intravascular ultrasound (IVUS)-guided procedures were performed in 279 (54%) patients and angiographic guidance was used in the remainder. Minimal lumen diameter was significantly greater in CBA-BMS than BA-BMS (2.65+/-0.40 mm vs 2.52+/-0.4 mm, p<0.01) and % diameter stenosis (%DS)-post was less in CBA-BMS than BA-BMS (14.0+/-5.9% vs 16.3+/-6.8%, p<0.01). %DS-follow-up was subsequently less in CBA-BMS than BA-BMS (32.4+/-15.1% vs 35.4+/-15.3%, p<0.05) associated with lower rates of restenosis in CBA-BMS than BA-BMS (11.8% vs 19.6%, p<0.05) and less target lesion revascularization (TLR) in CBA-BMS than BA-BMS (9.6% vs 15.3%, p<0.05). Patients were divided into 4 groups based on the device used before stenting and IVUS use (IVUS-CBA-BMS: 137 patients; Angio-CBA-BMS: 123; IVUS-BA-BMS: 142; and Angio-BA-BMS: 119). At follow-up IVUS-CBA-BMS had a significantly lower restenosis rate (6.6%) than Angio-CBA-BMS (17.9%), IVUS-BA-BMS (19.8%) and Angio-BA-BMS (18.2%, p<0.05). Restenosis and TLR were significantly lower in CBA-BMS than BA-BMS. This favorable outcome was achieved because of the lower restenosis rate conferred by the IVUS-guided-CBA-BMS strategy (6.6%). The restenosis rates obtained with this strategy were comparable to those achieved with DES.

  16. Ureteral stenting and urinary stone management: A systematic review

    NARCIS (Netherlands)

    Haleblian, George; Kijvikai, Kittinut; de la Rosette, Jean; Premingert, Glenn

    2008-01-01

    Purpose: Ureteral stents are widely used in many urological procedures. We evaluated the recent literature, providing an update on materials and stent designs, and indications for stent placement and stent complications, including the management of such stent related problems. Materials and Methods:

  17. Sirolimus-eluting versus bare-metal stent implantation in patients with ostial lesions

    DEFF Research Database (Denmark)

    Jørgensen, Erik; Kelbæk, Henning; Kløvgaard, Lene

    2010-01-01

    To investigate the efficacy of implantation of sirolimus-eluting stents (SES) in the ostium of coronary arteries.......To investigate the efficacy of implantation of sirolimus-eluting stents (SES) in the ostium of coronary arteries....

  18. Influence of a dexamethasone-eluting covered stent on tissue reaction: an experimental study in a canine bronchial model

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Song, Ho-Young; Choi, Gi Bok; Kim, Tae-Hyung; Suh, Ji-Yeon; Seo, Tae-Seok; Yuk, Soon Hong; Kim, Young-Hwa; Cho, Yong-Mee

    2005-01-01

    This study was designed to evaluate the feasibility and efficacy of a dexamethasone (DXM)-eluting, covered, self-expanding metallic stent to reduce tissue reaction following stent placement in a canine bronchial model. We placed a DXM-eluting, polyurethane-covered, self-expanding metallic stent (drug stent, DS) and a polyurethane-covered, self-expanding metallic stent (control stent, CS) alternately in each left main bronchus and left lower lobe bronchus in 12 dogs. The stents were 20 mm in diameter and length when fully expanded. The dose of DXM was approximately 36.7 mg in each DS, but was absent in the CS. The dogs were euthanased 1 week (n=4), 2 weeks (n=4) or 4 weeks (n=4) after stent placement. Histologic findings, such as epithelial erosion/ulcer or granulation tissue thickness, were obtained from the mid-portion of the bronchus, where the stent had been placed, and evaluated between DS and CS. There were no procedure-related complications or malpositioning of any of the bronchial stents. Stent migration was detected in one dog just before euthanasia 1 week following stent placement. Stent patency was maintained until euthanasia in all dogs. Epithelial erosion/ulcer (%) was significantly less in the DS (mean±standard deviation, 46.88±23.75) than in the CS (73.75±14.08) (P=0.026) for all time-points. There was a decrease in epithelial erosion/ulcer as the follow-up period increased in both DS and CS. The granulation tissue thickness (mm) was less in DS (2.63±2.05) than in CS (3.49±2.95), although the difference was not significant (P=0.751) for all time-points. There was a tendency toward an increase in granulation tissue thickness and chronic lymphocytic infiltration as the follow-up period increased in both DS and CS. In conclusion, DXM-eluting, covered, self-expanding metallic stent seems to be effective in reducing tissue reaction secondary to stent placement in a canine bronchial model. (orig.)

  19. Influence of a dexamethasone-eluting covered stent on tissue reaction: an experimental study in a canine bronchial model

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon; Song, Ho-Young; Choi, Gi Bok; Kim, Tae-Hyung; Suh, Ji-Yeon [University of Ulsan College of Medicine, Department of Radiology, Asan Medical Center, Seoul (Korea); Seo, Tae-Seok [Gachon Medical School, Department of Radiology, Gil Medical Center, Inchon (Korea); Yuk, Soon Hong [Hannam University, Department of Polymer Science and Engineering, College of Engineering, Daejeon (Korea); Kim, Young-Hwa [Soonchunhyang University Chonan Hospital, Department of Radiology, Chonan (Korea); Cho, Yong-Mee [University of Ulsan College of Medicine, Department of Pathology, Asan Medical Center, Seoul (Korea)

    2005-06-01

    This study was designed to evaluate the feasibility and efficacy of a dexamethasone (DXM)-eluting, covered, self-expanding metallic stent to reduce tissue reaction following stent placement in a canine bronchial model. We placed a DXM-eluting, polyurethane-covered, self-expanding metallic stent (drug stent, DS) and a polyurethane-covered, self-expanding metallic stent (control stent, CS) alternately in each left main bronchus and left lower lobe bronchus in 12 dogs. The stents were 20 mm in diameter and length when fully expanded. The dose of DXM was approximately 36.7 mg in each DS, but was absent in the CS. The dogs were euthanased 1 week (n=4), 2 weeks (n=4) or 4 weeks (n=4) after stent placement. Histologic findings, such as epithelial erosion/ulcer or granulation tissue thickness, were obtained from the mid-portion of the bronchus, where the stent had been placed, and evaluated between DS and CS. There were no procedure-related complications or malpositioning of any of the bronchial stents. Stent migration was detected in one dog just before euthanasia 1 week following stent placement. Stent patency was maintained until euthanasia in all dogs. Epithelial erosion/ulcer (%) was significantly less in the DS (mean{+-}standard deviation, 46.88{+-}23.75) than in the CS (73.75{+-}14.08) (P=0.026) for all time-points. There was a decrease in epithelial erosion/ulcer as the follow-up period increased in both DS and CS. The granulation tissue thickness (mm) was less in DS (2.63{+-}2.05) than in CS (3.49{+-}2.95), although the difference was not significant (P=0.751) for all time-points. There was a tendency toward an increase in granulation tissue thickness and chronic lymphocytic infiltration as the follow-up period increased in both DS and CS. In conclusion, DXM-eluting, covered, self-expanding metallic stent seems to be effective in reducing tissue reaction secondary to stent placement in a canine bronchial model. (orig.)

  20. 2-year clinical outcomes after implantation of sirolimus-eluting, paclitaxel-eluting, and bare-metal coronary stents: results from the WDHR (Western Denmark Heart Registry)

    DEFF Research Database (Denmark)

    Kaltoft, Anne; Jensen, Lisette Okkels; Maeng, Michael

    2009-01-01

    OBJECTIVES: This registry study assessed the safety and efficacy of the 2 types of drug-eluting stents (DES), sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES), compared with bare-metal stents (BMS). BACKGROUND: Drug-eluting stents may increase the risk of stent thrombosis (ST...... databases. We used Cox regression analysis to control for confounding. RESULTS: The 2-year incidence of definite ST was 0.64% in BMS patients, 0.79% in DES patients (adjusted relative risk [RR]: 1.09; 95% confidence interval [CI]: 0.72 to 1.65), 0.50% in SES patients (adjusted RR: 0.63, 95% CI: 0.35 to 1...

  1. Stents in patients with esophageal cancer before chemoradiotherapy: high risk of complications and no impact on the nutritional status.

    Science.gov (United States)

    Mão-de-Ferro, S; Serrano, M; Ferreira, S; Rosa, I; Lage, P; Alexandre, D P; Freire, J; Mirones, L; Casaca, R; Bettencourt, A; Pereira, A D

    2016-03-01

    Preoperative chemoradiotherapy is the standard of care for locally advanced esophageal cancer, causing persistent deterioration in the nutritional status. We performed a prospective study to evaluate the safety and efficacy of esophageal double-covered self-expandable metal stents in patients with esophageal cancer before chemoradiotherapy. The nutritional status and dysphagia were prospectively recorded. Eleven patients were included: eight were moderate and three were severely malnourished. After stent placement, dysphagia improved in all patients. With regard to complications, one patient developed an esophageal perforation that required urgent esophagectomy. Four patients presented stent migration. Three of these patients required enteral nutrition and none was submitted to surgery because of poor nutritional status. Of the other six patients, only four were operated upon. Stent placement presented a high complication rate and did not prevent weight loss or malnutrition. Other alternatives, including naso-gastric tube placement or endoscopic percutaneous gastrostomy or jejunostomy, should be considered.

  2. Endovascular Treatment of Ruptured Abdominal Aneurysm into the Inferior Vena Cava in Patient After Stent Graft Placement

    International Nuclear Information System (INIS)

    Juszkat, Robert; Pukacki, Fryderyk; Zarzecka, Anna; Kulesza, Jerzy; Majewski, Waclaw

    2009-01-01

    We report the case of a patient who underwent endovascular repair and then reintervention as a result of the presence of a persistent endoleak complicated by an aortocaval fistula. A 76-year-old patient with a history of endovascular treatment for abdominal aortic aneurysm 2 years earlier had a palpable abdominal mass, high-output cardiac failure, and renal failure. A computed tomographic scan and angiography revealed bending of the right iliac limb, a type I endoleak, and rupture of the aneurysm into the inferior vena cava with aortocaval fistula formation. An iliac extension was positioned in the right external iliac artery. The procedure was finished successfully. Control angiography showed normal flow within the endoprosthesis, and both iliac arteries were without signs of endoleakage and aortocaval fistula. Ectatic common iliac artery may lead to a late distal attachment site endoleak. The application of a stent graft in cases of secondary aortocaval fistula after stent graft repair is a good option, particularly in emergency cases.

  3. Immediate Outcomes of Covered Stent Placement for Treatment or Prevention of Aortic Wall Injury Associated With Coarctation of the Aorta (COAST II).

    Science.gov (United States)

    Taggart, Nathaniel W; Minahan, Matthew; Cabalka, Allison K; Cetta, Frank; Usmani, Kudret; Ringel, Richard E

    2016-03-14

    This study aimed to describe the safety and short-term efficacy of the Covered Cheatham-Platinum stent (CCPS) in treating or preventing aortic wall injury (AWI) in patients with coarctation of the aorta (CoA). The COAST II trial (Covered Cheatham-Platinum Stents for Prevention or Treatment of Aortic Wall Injury Associated with Coarctation of the Aorta Trial) is a multicenter, single-arm trial using the CCPS for the treatment and/or prevention of AWI in patients with CoA and pre-existing AWI or increased risk of AWI. Patients were enrolled if they had a history of CoA with pre-existing AWI (Treatment group) or with increased risk of AWI (Prevention group). Pre/post-implant hemodynamics and angiography were reported. A core laboratory performed standardized review of all angiograms. One-month follow-up was reported. A total of 158 patients (male = 65%; median age 19 years) underwent placement of CCPS. Eighty-three patients had pre-existing AWI. The average ascending-to-descending aorta systolic gradient improved from 27 ± 20 mm Hg to 4 ± 6 mm Hg. Complete coverage of pre-existing AWI was achieved in 66 of 71 patients (93%) with AWI who received a single CCPS. Ultimately, complete coverage of AWI was achieved in 76 of 83 patients (92%); 7 patients had minor endoleaks that did not require repeat intervention. Four patients experienced important access site vascular injury. There were no acute AWI, repeat interventions, or deaths. The CCPS can effectively treat and potentially prevent AWI associated with CoA. Access site arterial injury is the most common important complication. Longer-term follow-up is necessary to define mid- and late-term outcomes. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  4. Comparison of clinical outcomes between bioresorbable vascular stents versus conventional drug-eluting and metallic stents: a systematic review and meta-analysis.

    Science.gov (United States)

    Banach, Maciej; Serban, Maria-Corina; Sahebkar, Amirhossein; García-García, Hector M; Mikhailidis, Dimitri P; Martin, Seth S; Brie, Daniel; Rysz, Jacek; Toth, Peter P; Jones, Steven R; Hasan, Rani K; Mosteoru, Svetlana; Al Rifai, Mahmoud; Pencina, Michael J; Serruys, Patrick W

    2016-06-12

    Several studies have suggested good procedural and similar clinical outcomes between everolimus-eluting Absorb bioresorbable stents (BRS) versus conventional drug-eluting stents (DES), but the evidence is not definitive. Our aim was to perform a systematic review and meta-analysis to investigate the effects of BRS versus conventional drug-eluting and bare metallic stents on the cardiovascular endpoints and all-cause mortality. The follow-up in the included studies was up to 13 months. The following endpoints were evaluated: all-cause mortality, cardiac death, patient-oriented major adverse cardiac events (POCE), device-oriented major adverse cardiac events (DOCE), any-cause myocardial infarction (MI), target vessel MI (TVMI), target vessel revascularisation (TVR) and target lesion revascularisation (TLR). The results of 10 studies with 5,773 subjects showed a statistically significant increase in the risk of TVMI between BRS and conventional stents (odds ratio [OR]: 1.45, 95% confidence interval [CI]: 1.03-2.05, p=0.032). None of the other differences reached statistical significance: all-cause mortality (OR: 0.67, 95% CI: 0.30-1.49, p=0.333), cardiac death (OR: 1.00, 95% CI: 0.47-2.12, p=0.996), POCE (OR: 0.91, 95% CI: 0.68-1.22, p=0.546), DOCE (OR: 1.12, 95% CI: 0.86-1.46, p=0.387), any-cause MI (OR: 1.34, 95% CI: 0.98-1.82, p=0.064), TVR (OR: 0.99, 95% CI: 0.73-1.33, p=0.934) and TLR (OR: 0.92, 95% CI: 0.66-1.29, p=0.641). Similar results were observed after restricting the meta-analysis to the comparison of BRS vs. EES. Our meta-analysis suggests a significantly higher risk of TVMI with BRS compared with conventional stents and no significant differences in the rates of occurrence of the other outcomes during one-year follow-up. Further studies with larger samples sizes, longer follow-up, different clinical scenarios and more complex lesions are required to confirm or refute our findings.

  5. Chest pain following oesophageal stenting for malignant dysphagia

    International Nuclear Information System (INIS)

    Golder, Mark; Tekkis, Paris P.; Kennedy, Colette; Lath, Sadaf; Toye, Rosemary; Steger, Adrian C.

    2001-01-01

    AIM: The palliative use of self-expanding metallic stents has been widely reported to relieve dysphagia in cases of oesophageal carcinoma. Little has been documented on the severity of chest pain following oesophageal stenting. The aim of this study was to investigate the association of pain with oesophageal stenting for malignant dysphagia. METHODS: Fifty-two patients with inoperable oesophageal carcinoma underwent stent placement between 1995-1999. Daily opioid analgesic requirements (mg of morphine equivalent doses) were monitored for 3 days before and 7 days after stenting. The degree of palliation was expressed as a dysphagia score (0-3). Hospital stay, readmission days, stent complications and patient survival time were also recorded. RESULTS: Twenty-six patients (50%) required opioid analgesia for chest pain (median dose: 80 mg morphine/day) within 48 h of the procedure compared to 11 (21.2%) patients before stenting (P = 0.0041). A significant increase was evident in the analgesic consumption following stent deployment (P < 0.001). The dysphagia score improved by a median value of 1 (CI 0.25)P < 0.001, with a re-intervention rate of 11.5%. The median survival time was 40 days post stenting (range 1-120). CONCLUSION: A significant proportion of patients developed chest pain after oesophageal stenting, requiring high dose opioid analgesia. As the origin of the pain is still unknown, pre-emptive analgesia may a play role in reducing stent-related morbidity and possibly in-hospital stay. Golder, M. et al. (2001)

  6. Modified nasolacrimal duct stenting

    International Nuclear Information System (INIS)

    Tian Min; Jin Mei; Chen Huanjun; Li Yi

    2008-01-01

    Objective: Traditional nasolacrimal duct stenting possesses some shortcoming including difficulty of pulling ball head guide wire from the nasal cavity with turbinate hypertrophy and nasal septal deviation. The new method of nose-oral tube track establishment can overcome the forementioned and increase the successful rate. Methods: 5 F catheter and arterial sheath were modified to be nasolacrimal duct stent delivery device respectively. Antegrade dacryocystography was taken firstly to display the obstructed site and followed by the modified protocol of inserting the guide wire through nasolacrimal duct and nasal cavity, and establishing the stent delivery track for retrograde stent placement. Results: 5 epiphora patients with failure implantation by traditional method were all succeeded through the modified stenting (100%). During 6-mouth follow-up, no serious complications and reocclusion occurred. Conclusion: The establishment of eye-nose-mouth-nose of external nasal guide wire track can improve the successful rate of nasolacrimal duct stenting. (authors)

  7. Restenosis in coronary bare metal stents. Importance of time to follow-up: a comparison of coronary angiograms 6 months and 4 years after implantation

    DEFF Research Database (Denmark)

    Jørgensen, Erik; Helqvist, Steffen; Kløvgaard, Lene

    2008-01-01

    Objectives. Angiographic late lumen loss measured 6 to 9 month after bare metal stent implantation in the coronary arteries is a validated restenosis parameter. Design. We performed a second angiographic follow-up after 4 years in event free survivors from the DANSTENT trial cohort. Results......-sectional vessel area and a 39% reduction of the binary restenosis rate over time. Conclusions. Instent late lumen loss in bare metal stents decreases spontaneously over time. Maturation of early hyperplastic tissue reaction after stent implantation with subsequent thinning of fibrotic tissue might explain...

  8. Percutaneous Transhepatic Biliary Metal Stent for Malignant Hilar Obstruction: Results and Predictive Factors for Efficacy in 159 Patients from a Single Center

    Energy Technology Data Exchange (ETDEWEB)

    Li, Mingwu, E-mail: lmw-jack@china.com.cn; Bai, Ming, E-mail: mingbai1983@gmail.com; Qi, Xingshun, E-mail: qixingshun19840717@126.com; Li, Kai, E-mail: lkiscoming@163.com; Yin, Zhanxin, E-mail: yinzhanxin@sina.com [Fourth Military Medical University, Department of Digestive Interventional Radiology, Xijing Hospital of Digestive Diseases (China); Wang, Jianhong, E-mail: 54526844@qq.com [Fourth Military Medical University, Department of Ultrasound, Xijing Hospital of Digestive Diseases (China); Wu, Wenbing, E-mail: wuwb211@126.com; Zhen, Luanluan, E-mail: zll2007101@163.com; He, Chuangye, E-mail: sxhechuangye@126.com [Fourth Military Medical University, Department of Digestive Interventional Radiology, Xijing Hospital of Digestive Diseases (China); Fan, Daiming, E-mail: fandaim@fmmu.edu.cn [Fourth Military Medical University, State Key Laboratory of Cancer Biology and Xijing Hospital of Digestive Diseases (China); Zhang, Zhuoli, E-mail: Zhuoli-Zhang@northwestern.edu [Northwestern University, Department of Radiology (United States); Han, Guohong, E-mail: hangh2009@gmail.com, E-mail: Hangh@fmmu.edu.cn [Fourth Military Medical University, Department of Digestive Interventional Radiology, Xijing Hospital of Digestive Diseases (China)

    2015-06-15

    AimTo investigate and compare the efficacy and safety of percutaneous transhepatic biliary stenting (PTBS) using a one- or two-stage procedure and determine the predictive factors for the efficacious treatment of malignant hilar obstruction (MHO).Methods159 consecutive patients with MHO who underwent PTBS were enrolled between January 2010 and June 2013. Patients were classified into one- or two-stage groups. Independent predictors of therapeutic success were evaluated using a logistic regression model.Results108 patients were treated with one-stage PTBS and 51 patients were treated with two-stage PTBS. The stents were technically successful in all patients. Successful drainage was achieved in 114 patients (71.4 %). A total of 42 early major complications were observed. Re-interventions were attempted in 23 patients during follow-up. The cumulative primary patency rates at 3, 6, and 12 months were 88, 71, and 48 %, respectively. Stent placement using a one- or two-stage procedure did not significantly affect therapeutic success, early major complications, median stent patency, or survival. A stent placed across the duodenal papilla was an independent predictor of therapeutic success (odds ratio = 0.262, 95 % confidence interval [0.107–0.642]). Patients with stents across papilla had a lower rate of cholangitis compared with patients who had a stent above papilla (7.1 vs. 20.3 %, respectively, p = 0.03).ConclusionsThe majority of patients with MHO who underwent one-stage PTBS showed similar efficacy and safety outcomes compared with those who underwent two-stage PTBS. Stent placement across the duodenal papilla was associated with a higher therapeutic success rate.

  9. Renal Transplant Arterial Stenosis Treated With Bare-Metal Versus Drug-Eluting Stents: Comparison of Treatment Outcomes.

    Science.gov (United States)

    Hanna, R F; Hao, F; Kraus, C F; Mitsopoulos, G; Goldstein, G E; Weintraub, J; Sperling, D; Susman, J; Schlossberg, P; Sheynzon, V

    2015-12-01

    This study aims to evaluate outcomes of bare-metal stents (BMS) versus drug-eluting stents (DES) in patients who undergo stenting for transplant renal arterial stenosis. We retrospectively reviewed records of renal transplantation patients who underwent transplant renal arterial stenting from September 2009 to September 2013. All stents greater than 5 mm were excluded to allow for equivalent comparison between the DES and BMS groups. Statistical comparisons were performed using a two-tailed Fischer exact test, and analysis of continuous variables was analyzed using a one-way analysis of variance. The final study population included a total of 18 patients who received either BMS or DES (11 and 7 patients, respectively) for transplant renal arterial stenosis. The most common indications for stenting were increasing creatinine level and abnormal Doppler velocities. There were more re-interventions with BMS (n = 4/11) than DES (n = 0/7), but the trend was not statistically significant (P = .12). Three patients who received BMS had a clinically significant decrease in blood pressure versus 4 in the DES group (P = .33). Six patients who received BMS had a clinically significant decrease in creatinine level versus 3 in the DES group (P = 1.0). There is an absolute but not statistically significant difference in the incidence of restenosis requiring repeat intervention between the BMS and DES groups. No difference was detected in clinical success as measured by decreases in blood pressure or creatinine. Future larger studies are needed to corroborate these findings. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Covered versus uncovered metal stents for malignant gastric outlet obstruction: Systematic review and meta-analysis.

    Science.gov (United States)

    Hamada, Tsuyoshi; Hakuta, Ryunosuke; Takahara, Naminatsu; Sasaki, Takashi; Nakai, Yousuke; Isayama, Hiroyuki; Koike, Kazuhiko

    2017-05-01

    Self-expandable metal stents (SEMS) are used for non-resectable malignant gastric outlet obstruction (GOO). Studies of covered versus uncovered SEMS have yielded inconsistent results as a result of heterogeneity in design and patient population. We carried out a meta-analysis to compare covered and uncovered gastroduodenal SEMS. Using MEDLINE, Embase, and the Cochrane database, we identified 1624 patients from 13 prospective and retrospective studies that evaluated covered and uncovered SEMS for malignant GOO and were published until October 2016. We pooled data on SEMS dysfunction, technical and clinical success, and adverse events using the fixed-effect or random-effects model. Compared with uncovered SEMS, covered SEMS did not show any significant difference in stent dysfunction risk (risk ratio [RR], 1.02; 95% confidence interval [CI], 0.79-1.32). A subgroup analysis of five randomized trials suggested a trend toward a lower dysfunction risk in covered SEMS (RR, 0.63; 95% CI, 0.45-0.88). Covered SEMS were associated with a lower occlusion risk (RR, 0.44; 95% CI, 0.28-0.68), but with a higher migration risk (RR, 4.28; 95% CI, 2.89-6.34). Technical and clinical success rates were comparable between the groups. Overall adverse events tended to be more frequent in covered SEMS (RR, 1.75; 95% CI, 1.09-2.83). Outcomes of covered and uncovered gastroduodenal SEMS were comparable, although the lower dysfunction rate of covered SEMS observed in the analysis of randomized trials needs further investigation. Antimigration mechanisms for covered SEMS and identification of patients who can achieve longer patency from uncovered SEMS would help improve the outcomes of gastroduodenal SEMS. © 2016 Japan Gastroenterological Endoscopy Society.

  11. Conformability in everolimus-eluting bioresorbable scaffolds compared with metal platform coronary stents in long lesions.

    Science.gov (United States)

    Fam, Jiang Ming; Ishibashi, Yuki; Felix, Cordula; Zhang, Bu Chun; Diletti, Roberto; van Mieghem, Nicolas; Regar, Evelyn; van Domburg, Ron; Onuma, Yoshinobu; van Geuns, Robert-Jan

    2017-12-01

    The aim of this study was to determine if there are significant differences in curvature of the treated vessel after the deployment of a polymeric BRS or MPS in long lesions. The impact of long polymeric bioresorbable scaffolds (BRS) compared with metallic platform stents (MPS) on vessel curvature is unknown. This retrospective study compares 32 patients who received a single everolimus-eluting BRS with 32 patients treated with a single MPS of 28 mm. Quantitative coronary angiography (QCA) was used to evaluate curvature of the treatment and peri-treatment region before and after percutaneous coronary intervention (PCI). Baseline demographic and angiographic characteristics were similar between the BRS and MPS groups. Pretreatment lesion length was 22.19 versus 20.38 mm in the BRS and MPS groups respectively (p = 0.803). After treatment, there was a decrease in median diastolic curvature in the MPS group (from 0.257 to 0.199 cm -1 , p = 0.001). A similar trend was observed in the BRS group but did not reach statistical significance (median diastolic curvature from 0.305 to 0.283 cm -1 , p = 0.056). Median Percentage relative change in diastolic curvature was lower in the BRS group compared with the MPS group (BRS vs. MPS: 7.48 vs. 29.4%, p = 0.013). By univariate analysis, use of MPS was an independent predictor of change in diastolic curvature (p = 0.022). In the deployment of long coronary scaffolds/stents (28 mm in length), BRS provides better conformability compared with MPS.

  12. Stent intussusception after thromboaspiration through a platinum chrome stent: a particular case of longitudinal stent deformation.

    Science.gov (United States)

    Mila, Rafael; Vignolo, Gustavo; Trujillo, Pedro

    2015-04-01

    The need to improve stent deliverability has led to the development of thinner and more flexible stents. However, there is concern about decreased longitudinal strength. The number of longitudinal stent deformation reports has dramatically increased. We report a case of stent longitudinal deformation after thromboaspiration through a new generation platinum chrome bare metal stent. Images show an "intussusception effect," an extreme form of the previously described "concertina deformation," as the mechanism of shortening. Since stent technology is constantly evolving, newer devices will probably be designed to have less susceptibility to longitudinal stent deformation.

  13. Management of recurrent bulbar urethral stricture-a 54 patients study with Allium bulbar urethral stent (BUS).

    Science.gov (United States)

    Culha, Melih; Ozkuvanci, Unsal; Ciftci, Seyfettin; Saribacak, Ali; Ustuner, Murat; Yavuz, Ufuk; Yilmaz, Hasan; Ozkan, Levend

    2014-01-01

    The Allium Bulbar Urethral Stent (BUS) is a fully covered, self-expandable, large caliber metal stent specially designed for the treatment of bulbar urethra strictures. The stent is intended for a long term use for the purpose of opening the occluded urethral passage and to allow spontaneous urination. This study objective was to evaluate the clinical efficacy of temporary placement of the Allium BUS stent. This was a prospective study in 54 men with recurrent benign urethral stricture conducted during 2009 to 2012. All men underwent an internal urethrotomy or dilatation procedure followed by an endoscopic stent placement. Clinical success was achieved in 44 (81.4%) of the 54 patients. No patient reported discomfort at the stent site. 2 stents migrated distally. 1 stent was occluded. All stents were removed in a mean time of 8.8 (range 3-18) months following implantation. This experience with the Allium BUS for treating urethral strictures suggests that it is safe and reliable treatment modality.

  14. A Zr-based bulk metallic glass for future stent applications: Materials properties, finite element modeling, and in vitro human vascular cell response.

    Science.gov (United States)

    Huang, Lu; Pu, Chao; Fisher, Richard K; Mountain, Deidra J H; Gao, Yanfei; Liaw, Peter K; Zhang, Wei; He, Wei

    2015-10-01

    Despite the prevalent use of crystalline alloys in current vascular stent technology, new biomaterials are being actively sought after to improve stent performance. In this study, we demonstrated the potential of a Zr-Al-Fe-Cu bulk metallic glass (BMG) to serve as a candidate stent material. The mechanical properties of the Zr-based BMG, determined under both static and cyclic loadings, were characterized by high strength, which would allow for the design of thinner stent struts to improve stent biocompatibility. Finite element analysis further complemented the experimental results and revealed that a stent made of the Zr-based BMG was more compliant with the beats of a blood vessel, compared with medical 316L stainless steel. The Zr-based BMG was found to be corrosion resistant in a simulated body environment, owing to the presence of a highly stable ZrO2-rich surface passive film. Application-specific biocompatibility studies were conducted using human aortic endothelial cells and smooth muscle cells. The Zr-Al-Fe-Cu BMG was found to support stronger adhesion and faster coverage of endothelial cells and slower growth of smooth muscle cells than 316L stainless steel. These results suggest that the Zr-based BMG could promote re-endothelialization and potentially lower the risk of restenosis, which are critical to improve vascular stent implantation integration. In general, findings in this study raised the curtain for the potential application of BMGs as future candidates for stent applications. Vascular stents are medical devices typically used to restore the lumen of narrowed or clogged blood vessel. Despite the clinical success of metallic materials in stent-assisted angioplasty, post-surgery complications persist due to the mechanical failures, corrosion, and in-stent restenosis of current stents. To overcome these hurdles, strategies including new designs and surface functionalization have been exercised. In addition, the development of new materials with

  15. Role of fluoroscopic guided self expandable metallic stents in the management of malignant esophageal strictures

    Directory of Open Access Journals (Sweden)

    Mohamed Shaker

    2016-09-01

    Conclusion: Fluoroscopic guided esophageal stenting is a highly effective and safe method for palliating dysphagia in patients with obstructing esophageal cancer with significant clinical improvement.

  16. A comparison of drug-eluting stents versus bare metal stents in saphenous vein graft PCI outcomes: a meta-analysis.

    Science.gov (United States)

    Mamas, Mamas A; Foley, James; Nair, Satheesh; Wiper, Andrew; Clarke, Bernard; El-Omar, Magdi; Fraser, Douglas G; Khattar, Rajdeep; Neyses, Ludwig; Fath-Ordoubadi, Farzin

    2011-04-01

    Studies demonstrate that percutaneous coronary intervention (PCI) with drug-eluting stents (DES) is associated with reduced revascularization and major adverse cardiac events (MACE) rates compared to bare metal stents (BMS) in native coronary vessels. Optimal PCI treatment of saphenous vein graft (SVG) lesions remains unclear despite SVG procedures representing up to 10% of PCI cases. We therefore performed a meta-analysis to compare outcomes between BMS and DES in SVG PCI. A search (2004-2009) of MEDLINE and conference proceedings for all relevant studies comparing mortality and MACE outcomes in DES versus BMS in SVG PCI and meta-analysis of the data was performed. Twenty studies were identified from 2005 to 2009 enrolling a total of 5,296 patients. Meta-analysis revealed a decrease in mortality associated with DES use, odds ratio (OR) 0.68; 95% confidence interval (CI) 0.53-0.88; P = 0.004. Similarly, MACE (OR 0.64; 95% CI 0.51-0.82; P DES were used compared to BMS. This reduction in mortality and MACE events associated with DES use appears to be limited to registry studies and not randomized controlled studies. Our meta-analysis suggests DES use to be safe in SVG PCI and associated with reduced mortality and MACE rates with reductions in revascularization also observed. ©2011, Wiley Periodicals, Inc.

  17. Drug-eluting stents vs. bare metal stents in saphenous vein graft disease. Insights from a meta-analysis of 7,090 patients.

    Science.gov (United States)

    Lupi, Alessandro; Navarese, Eliano Pio; Lazzero, Maurizio; Sansa, Mara; De Servi, Stefano; Serra, Antonio; Bongo, Angelo Sante; Buffon, Antonio

    2011-01-01

    Evidence supporting the use of drug-eluting stents (DES) in saphenous vein graft (SVG) disease is uncertain. Previous studies have suggested that DES might reduce the re-intervention rate in SVG disease, with conflicting data on mortality. Thus, a meta-analysis was performed to compare outcomes of DES vs. bare metal stent (BMS) in SVG disease. Medline and Web databases were searched for studies comparing DES and BMS for SVG disease, reporting rates of overall mortality, target vessel revascularization (TVR) and myocardial infarction (MI) with a follow-up of ≥6 months. The meta-analysis included 23 studies (7,090 patients). Compared with BMS, DES-treated patients had lower rates of TVR (odds ratio (OR), 0.53; confidence interval (CI), 0.39-0.72; PDES improved mortality rates, and randomized trials, in which benefit from DES was not evident. Meta-regression analysis showed that DES were more effective in the presence of older grafts and type 2 diabetes. The present meta-analysis showed that, in SVG disease, DES significantly reduced TVR, but did not provide clear benefits on mortality and MI, with an opposite direction of results in mortality observed from randomized and observational data.

  18. Gastrointestinal stenting

    International Nuclear Information System (INIS)

    Zollikofer, C.L.; Schoch, E.; Jost, R.; Decurtins, M.

    2000-01-01

    Acute obstructions of the gastric outlet, the duodenum, or the large bowel require rapid treatment to relieve symptoms of retention or ileus. Large-caliber stents of 16 to 22 mm offer a new non-surgical alternative for treating these patients with minimal risks and high success rates. For gastroduodenal outlet obstructions palliated by self-expanded metal stents, clinical success rates are in the range of 80-100 %. Preoperative treatment of colorectal obstructions successfully relieves acute symptoms of ileus in 87-100 % allowing primary anastomosis and thereby reducing the costs caused by multiple operations and the need of intensive care by approximately 25 %. It is the purpose of this review to familiarize the reader with the indications, possibilities, and limits of intestinal stenting. (orig.)

  19. Comparison of outcome in 1809 patients treated with drug-eluting stents or bare-metal stents in a real-world setting

    Directory of Open Access Journals (Sweden)

    Vogt A

    2011-11-01

    Full Text Available Alexander Vogt1, Anke Schoelmerich1, Franziska Pollner1, Manuela Schlitt1, Uwe Raaz1, Lars Maegdefessel2, Iris Reindl1, Michael Buerke1, Karl Werdan1, Axel Schlitt11Department of Medicine III, Martin Luther-University, Halle, Germany; 2Division of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, CA, USAPurpose: The aim of this study was to determine the long-term safety of drug-eluting stent (DES versus bare metal stent (BMS implantation in a “real-world” setting.Patients and methods: A total of 1809 patients who were treated with implantation of either BMS or DES were assessed. Kaplan-Meier and multivariate Cox regression analyses concerning primary endpoint of cardiac mortality were performed.Results: A total of 609 patients received DES. Mean age was 66.2 ± 11.3 years, 69.4% were male, and 1517 (83.8% were treated for acute coronary syndrome (unstable angina 510 [28.2%], non-ST-elevation myocardial infarction [NSTEMI] 506 [28.0%], and ST-elevation myocardial infarction [STEMI] 501 [27.7%]. Mean follow-up was 34 ± 15 months. During follow-up, 268 patients died of cardiac causes (DES 42 [7.3%]; BMS 226 [19.6%]; P < 0.001. Univariate Kaplan-Meier analysis showed an advantage of DES over BMS concerning the primary endpoint (P < 0.001. When adjusting for classic risk factors and additional factors that affect the progression of coronary heart disease (CHD, DES was not found to be superior to BMS (hazard ratio 0.996, 95% confidence interval 0.455–2.182, P = 0.993. Severely impaired renal function was an independent predictor for cardiac mortality after stent implantation.Conclusion: Treatment with DES is safe in the long term, also in patients presenting with STEMI. However, in multivariate analyses it is not superior to BMS treatment.Keywords: coronary stent, outcome, renal insufficiency, myocardial infarction, STEMI

  20. Stent thrombosis with second-generation drug-eluting stents compared with bare-metal stents: network meta-analysis of primary percutaneous coronary intervention trials in ST-segment–elevation myocardial infarction [corrected].

    Science.gov (United States)

    Philip, Femi; Agarwal, Shikhar; Bunte, Matthew C; Bunte, Matthew; Goel, Sachin S; Tuzcu, E Murat; Ellis, Stephen; Kapadia, Samir R

    2014-02-01

    The relative safety of drug-eluting stents (DESs) and bare-metal stents (BMSs) with respect to stent thrombosis (ST) continues to be debated. There are limited data comparing safety and efficacy of second-generation DES to BMS. We compared the clinical outcomes between second-generation DES and BMS for primary percutaneous coronary intervention using network meta-analysis. Randomized controlled trials comparing stent types (first-generation DES, second-generation DES or BMS) were considered for inclusion. A search strategy used Medline, Embase, Cochrane databases, and proceedings of the international meetings. Information about study design, inclusion criteria, and sample characteristics were extracted. Network meta-analysis was used to pool direct (comparison of second-generation DES to BMS) and indirect evidence (first-generation DES with BMS and second-generation DES) from the randomized trials. Twenty-one trials comparing all stents types, including 12 866 patients randomly assigned to treatment groups, were analyzed. A significantly lower incidence of ST was noted with the use of second-generation DES as early as 30 days (odds ratio [OR], 0.36; 95% confidence interval [CI], 0.15-0.82) and between 31 days and 1 year (OR, 0.49; 95% CI, 0.30-0.79) when compared with BMS. Second-generation DES was associated with significantly lower incidence of definite ST at 1 year (OR, 0.3; 95% CI, 0.11-0.83) and myocardial infarction (OR, 0.3; 95% CI, 0.17-0.54) and target vessel revascularization at 1 year (OR, 0.54; 95% CI, 0.80-0.98) when compared with BMS. There was no difference in mortality at 30 days (OR, 0.84; 95% CI, 0.45-1.59) or 1 year (OR, 0.80; 95% CI, 0.56-1.14) with the use of second-generation DES versus BMS. The small number of events may influence the precision of the analysis. Network meta-analysis of randomized trials of primary percutaneous coronary intervention demonstrated lower incidence of ST, myocardial infarction, and target vessel revascularization

  1. Experimental study of different nickel-titanium memory tracheal stents in dogs

    International Nuclear Information System (INIS)

    Lang Xu; He Nengshu; Fan Hailun

    2009-01-01

    Objective: Since membrane -covered metal tracheal stent was applied successfully to treat the airway stenosis, it has been widely used and obtained satisfactory result during the past years. The purpose of our study was provide theoretical rational for treatment with membrane-covered tracheal stent by using animal experiment. Methods: The nickel- titanium memory stents of 22 mm in diameter and 6 cm in length were deployed in 18 dogs. The dogs were grouped into full- length membrane-covered group (n=6), partial-length membrane-covered group (membrane was covered for 4 cm in the medial part of the stent, n=6), and naked stent group (n=6). After the stent placement dysphagia or dysphonia was monitored daily. Twenty-four weeks later, the dogs were executed. Speiments were taken from the cephalic, medial, and caudal trachea under the stent. HE stain and proliferating cell nuclear antigen (PCNA) were evaluated. Results: After the stent placement, no dyspnea, dysphagia or dysphonia but cough was present in each dog. There was no significant difference in symptom between the three groups. Inflammation reaction, metaplasia from low columnar epithelium to spuamous epithelium, and mild granulation tissue hyperplasia in the underlying mucosa were present in each group. However, fibrosis and tracheal straitness were present only in the non-membrane-covered area, but not in the membrane-covered area. More PCNA expression was observed in the non-membrane -covered area than in the membrane-covered area. Conclusion: Both membrane-covered and non-membrane-covered stents can cause similar symptoms. However, the membrane -covered tracheal stent has good biological compatibility and would not induce tracheal straitness. The non-membrane -covered tracheal stent could induce a severe pathologic reaction and tracheal straitness. (authors)

  2. [Retrieval of a migrated plastic stent in a 51-year-old man].

    Science.gov (United States)

    Poszler, A; Klare, P; Weber, A; Abdelhafez, M; Holzapfel, K; Schmid, R M; von Delius, S

    2018-04-16

    Endosonographically guided transgastric drainage is the first-line interventional therapy of walled-off necrosis and symptomatic pancreatic pseudocysts in necrotizing pancreatitis. Plastic stents or lumen apposing metal stents are commonly used. A possible complication of endoscopic therapy is stent migration. We report upon a 51-year-old man who presented with acute necrotizing pancreatitis. Transgastric necrosectomy was performed and 5 transmural double-pigtail stents (DPS) were left in situ to drain the residual retroperitoneal cavity. The patient recovered and 4 stents were endoscopically removed 5 weeks later on an outpatient basis, whereas the fifth stent was suspected to have passed spontaneously via the natural route. The asymptomatic patient presented 3 months later for follow-up computed tomography. The necrosis had healed but one DPS was seen beyond the gastric wall near the kidney. Transmural access to the stent could be achieved by an endosonographically guided puncture toward the proximal portion of the stent followed by placement of a hydrophilic guidewire alongside the stent. A new gastrostomy was created by using a 6F cystotome followed by wire-guided dilation with a 12 mm balloon. The stent could then be grasped with transmurally inserted rat-tooth forceps and repositioned across the gastrostomy site. The patient was given prophylactic antibiotics. After removal of the stent, the patient could be discharged. Herein, we present the successful endosonographically guided transmural removal of a retroperitoneally migrated plastic stent. Of note, in our patient we had to rely completely on endosonography and radiography for localization and targeting of the stent, since the former necrotic cavity had meanwhile completely healed.

  3. Bare-metal vs. drug-eluting stents in patients with atrial fibrillation undergoing percutaneous coronary intervention.

    Science.gov (United States)

    Kiviniemi, Tuomas; Puurunen, Marja; Schlitt, Axel; Rubboli, Andrea; Karjalainen, Pasi; Nammas, Wail; Kirchhof, Paulus; Biancari, Fausto; Lip, Gregory Yh; Airaksinen, Ke Juhani

    2014-01-01

    We explored 12-month clinical outcomes of 929 patients with atrial fibrillation (AF) undergoing percutaneous coronary intervention (PCI) with bare-metal stents (BMS) vs. drug-eluting stents (DES) from the prospective multicenter AFCAS (Atrial Fibrillation undergoing Coronary Artery Stenting) registry. METHODS AND RESULTS: Endpoints included the first occurrence of major adverse cardiac and cerebrovascular events (MACCE), defined as a composite of all-cause death, myocardial infarction (MI), target vessel revascularization, definite/probable stent thrombosis (ST), transient ischemic attack or stroke. Bleeding events were defined according to the Bleeding Academic Research Consortium criteria. Altogether, 673 (72.4%) patients received BMS and 220 (23.7%) at least one DES. Patients treated with DES more often had diabetes and prior ischemic events, and a longer stent length (Pheart failure and were more likely to present with acute ST-elevation MI (P<0.05 for both). At 12-month follow-up, rates and risks of MACCE and total bleeding events were comparable between the groups (22.0% with BMS vs. 19.5% with DES, P=0.51, hazard ratio (HR) 0.89, 95% confidence interval (CI) 0.63-1.25 for DES) and (19.5% vs. 15.0%, respectively, P=0.16, HR 0.75, 95% CI 0.51-1.09 for DES). Definite/probable ST was more frequent in the BMS group (1.9% vs. 0%, respectively, P=0.046). In real-world patients with AF undergoing PCI, DES use was associated with outcomes comparable to those with BMS without excess bleeding complications. More ST was seen in BMS-treated patients.

  4. Comparative Study of Esophageal Self-expandable Metallic Stent Insertion and Gastrostomy Feeding for Dysphagia Caused by Lung Cancer.

    Science.gov (United States)

    Kim, Jihye; Min, Yang Won; Lee, Hyuk; Min, Byung Hoon; Lee, Joon Haeng; Rhee, Poong Lyul; Kim, Jae J

    2018-03-25

    Dysphagia is encountered in a large proportion of patients with lung cancer and is associated with malnutrition and a poor quality of life. This study compared the clinical outcomes of self-expandable metallic stent (SEMS) insertion and percutaneous gastrostomy (PG) feeding for patients with lung cancer and dysphagia. A total of 261 patients with lung cancer, who underwent either SEMS insertion (stent group) or PG (gastrostomy group) as an initial treatment procedure for dysphagia between July 1997 and July 2015 at the Samsung Medical Center, were reviewed retrospectively, and 84 patients with esophageal obstruction were identified. The clinical outcomes, including the overall survival, additional intervention, complications, and post-procedural nutritional status in the two groups, were compared. Among the 84 patients finally analyzed, 68 patients received SEMS insertion and 16 had PG. The stent group had less cervical obstruction and more mid-esophageal obstruction than the gastrostomy group. The Kaplan-Meier curves revealed similar overall survival in the two groups. Multivariate analysis showed that the two modalities had similar survival rates (PG compared with SEMS insertion, hazard ratio 0.682, p=0.219). Fifteen patients (22.1%) in the stent group received additional intervention, whereas there was no case in the gastrostomy group (p=0.063). The decrease in the serum albumin level after the procedure was lower in the gastrostomy group than in the stent group (-0.20±0.54 g/dL vs. -0.65±0.57 g/dL, p=0.013). SEMS insertion and PG feeding for relieving dysphagia by lung cancer had a comparable survival outcome. On the other hand, PG was associated with a better nutritional status.

  5. Bare metal vs. drug-eluting stents for extracranial vertebral artery disease: a meta-analysis of nonrandomized comparative studies.

    Science.gov (United States)

    Langwieser, Nicolas; Buyer, Dominique; Schuster, Tibor; Haller, Bernhard; Laugwitz, Karl-Ludwig; Ibrahim, Tareq

    2014-10-01

    To compare through meta-analysis the use of drug-eluting stents (DES) vs. bare metal stents (BMS) in the treatment of extracranial vertebral artery (EVA) disease. A literature search of the PubMed database was conducted to identify English-language articles in which both BMS and DES stenting were performed for EVA stenosis by the same investigator(s). Further, eligible studies had to provide data on in-stent restenosis during follow-up. The search identified 9 nonrandomized studies that met the inclusion criteria. The random effects model was employed to pool data. Meta-regression analyses were performed to evaluate the relationships between risk of restenosis and the age of patients, the length of follow-up, or the percentage of male patients. Reported technical success was high (range 99.2%-100%) and comparable for BMS [100% (276/276)] and DES [99.4% (166/167)]. The use of DES was associated with significantly lower (pDES showed significantly lower symptomatic restenosis rates as compared to BMS [4.7% (8/169) for DES vs. 11.6% (32/275) for BMS; p=0.005]. There was no change in the risk of restenosis for any factor explored in the meta-regression analysis. This meta-analysis demonstrates that the use of DES for extracranial vertebral artery stenting significantly reduces both the rate of restenosis and recurrence of symptoms as compared to BMS. In future, randomized trials are needed to support these findings.

  6. Drug-eluting vs. bare-metal stents for treatment of acute myocardial infarction with renal insufficiency. Results from Korea Acute Myocardial Infarction Registry.

    Science.gov (United States)

    Bae, Eun Hui; Lim, Sang Yup; Choi, Young Hwan; Suh, Sang Heon; Cho, Kyung Hoon; Choi, Joon Seok; Kim, Chang Seong; Park, Jeong Woo; Ma, Seong Kwon; Jeong, Myung Ho; Kim, Soo Wan

    2011-01-01

    Patients with chronic kidney disease have had conflicting results between drug-eluting stents (DES) and bare-metal stents (BMS). The aim of the present study was to determine whether DES is preferable for the treatment of acute myocardial infarction (AMI) with renal insufficiency, and to elucidate the impact of diabetes mellitus (DM) on outcomes of each stent. As a part of the Korea Acute Myocardial Infarction Registry (KAMIR), 2,175 AMI patients with renal insufficiency (glomerular filtration rate renal insufficiency, DES implantation exhibits a favorable 1-year clinical outcome than BMS implantation, and subgroup analysis for diabetic subjects showed worse outcomes in the DM group with implanted DES.

  7. Long-term clinical and economic analysis of the Endeavor drug-eluting stent versus the Driver bare-metal stent: 4-year results from the ENDEAVOR II trial (Randomized Controlled Trial to Evaluate the Safety and Efficacy of the Medtronic AVE ABT-578 Eluting Driver Coronary Stent in De Novo Native Coronary Artery Lesions).

    Science.gov (United States)

    Eisenstein, Eric L; Wijns, William; Fajadet, Jean; Mauri, Laura; Edwards, Rex; Cowper, Patricia A; Kong, David F; Anstrom, Kevin J

    2009-12-01

    This study was designed to evaluate long-term clinical and economic outcomes for subjects receiving Endeavor drug-eluting versus Driver bare-metal stents (both Medtronic CardioVascular, Santa Rosa, California). Early studies found that the drug-eluting stent (DES) was a clinically and economically attractive alternative to the bare-metal stent; however, associations between DES and very late stent thrombosis suggest that longer follow-up is required. We used clinical, resource use and follow-up data from 1,197 subjects randomized to receive Endeavor (n = 598) versus Driver (n = 599) stents in ENDEAVOR II (Randomized Controlled Trial to Evaluate the Safety and Efficacy of the Medtronic AVE ABT-578 Eluting Driver Coronary Stent in De Novo Native Coronary Artery Lesions) study with Medicare cost weights and quality of life adjustments applied from secondary sources. We compared differences through 4-year follow-up (1,440 days). Patients in both treatment groups had similar baseline characteristics. The use of Endeavor versus Driver reduced 4-year target vessel revascularization rates per 100 subjects (10.4 vs. 21.5; difference: -11.1; 95% confidence interval [CI]: -16.0 to -6.1; p AVE ABT-578 Eluting Driver Coronary Stent in De Novo Native Coronary Artery Lesions [ENDEAVOR II]; NCT00614848).

  8. Sustained Benefit at 2 Years for Covered Stents Versus Bare-Metal Stents in Long SFA Lesions: The VIASTAR Trial

    Energy Technology Data Exchange (ETDEWEB)

    Lammer, Johannes, E-mail: jlammer@gmx.at, E-mail: johannes.lammer@meduniwien.ac.at [Medical University Vienna, The Department of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy (Austria); Zeller, Thomas, E-mail: thomas.zeller@universitaets-herzzentrum.de [Universitaets-Herzzentrum Freiburg-Bad Krozingen, Department of Angiology (Germany); Hausegger, Klaus A., E-mail: klaus.hausegger@lkh-klu.at [Klinikum Klagenfurt, The Department of Diagnostic and Interventional Radiology (Austria); Schaefer, Philipp J., E-mail: jp.schaefer@rad.uni-kiel.de [University Clinics Schleswig-Holstein, The Department of Radiology (Germany); Gschwendtner, Manfred, E-mail: manfred.gschwendtner@elisabethinen.or.at [Elisabethinen Hospital, The Department of Diagnostic and Interventional Radiology (Austria); Mueller-Huelsbeck, Stefan, E-mail: muehue@diako.de [Diakonissen Hospital, The Department of Diagnostic and Interventional Radiology (Germany); Rand, Thomas, E-mail: thomas.rand@wienkav.at [Hietzing Hospital, The Department of Radiology (Austria); Funovics, Martin, E-mail: martin.funovics@meduniwien.ac.at; Wolf, Florian, E-mail: florian.wolf@meduniwien.ac.at [Medical University Vienna, The Department of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy (Austria); Rastan, Aljoscha, E-mail: aljoscha.rastan@universitaets-herzzentrum.de [Universitaets-Herzzentrum Freiburg-Bad Krozingen, Department of Angiology (Germany); Gschwandtner, Michael, E-mail: michael.gschwandtner@meduniwien.ac.at [Medical University Vienna, The Department of Angiology (Austria); Puchner, Stefan, E-mail: stefan.puchner@meduniwien.ac.at [Medical University Vienna, The Department of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-guided Therapy (Austria); and others

    2015-02-15

    PurposeThe hypothesis that covered stents are superior to bare-metal stents (BMS) in long femoropopliteal artery disease was tested. The one-year results of the VIASTAR trial revealed a patency benefit of covered stents in the treatment-per-protocol (TPP) analysis only.MethodsA prospective, randomized, single-blind, multicenter study evaluated 141 patients with symptomatic peripheral arterial disease (PAD) after treatment with heparin-bonded covered stents (VIABAHN{sup ®} Endoprosthesis) or BMS. Clinical outcomes and patency rates were assessed at 1, 6, 12, and 24 months. Mean lesion length was 19.0 ± 6.3 cm in the VIABAHN{sup ®} versus 17.3 ± 6.6 cm in the BMS group.ResultsThe 24-month primary patency rates in the VIABAHN{sup ®} and BMS group were: intention-to-treat 63.1 (95 % CI 0.52–0.76) versus 41.2 % (95 % CI 0.29–0.57; log rank p = 0.04) and TPP 69.4 (95 % CI 0.58–0.83) versus 40.0 % (95 % CI 0.28–0.56; log rank p = 0.004). Freedom from target-lesion-revascularization (TLR) was 79.4 (95 % CI 0.70–0.90) versus 73.0 % (95 % CI 0.63–0.85) for VIABAHN{sup ®} versus BMS (log rank p = 0.37). For the TPP group in lesions ≥20 cm, the 24-month patency rates were 65.2 (95 % CI 0.50–0.85) versus 26.7 % (95 % CI 0.12–0.59; log rank p = 0.004) for VIABAHN{sup ®} versus BMS, and freedom from TLR was 80.0 (95 % CI 0.68–0.94) versus 61.9 % (95 % CI 0.44–0.87; log rank p = 0.13). The ankle brachial index was 0.89 ± 0.18 versus 0.91 ± 0.17 (p = 0.76) at 24-month in the VIABAHN{sup ®} versus the BMS group, respectively.ConclusionAt 24-month, this trial in PAD patients with long femoropopliteal lesions demonstrated a significantly improved primary patency rate for heparin-bonded covered stents compared to BMS, however, without a significant impact on clinical outcomes and TLR rate (Reg. Nr. ISRCTN48164244)

  9. Stent versus gastrojejunostomy for the palliation of gastric outlet obstruction: A systematic review

    NARCIS (Netherlands)

    S.M. Jeurnink (Suzanne); C.H.J. van Eijck (Casper); E.W. Steyerberg (Ewout); E.J. Kuipers (Ernst); P.D. Siersema (Peter)

    2007-01-01

    textabstractBackground: Gastrojejunostomy (GJJ) is the most commonly used palliative treatment modality for malignant gastric outlet obstruction. Recently, stent placement has been introduced as an alternative treatment. We reviewed the available literature on stent placement and GJJ for gastric

  10. Percutaneous coronary revascularization using a trilayer metal phosphorylcholine-coated zotarolimus-eluting stent.

    Science.gov (United States)

    Abizaid, Alexandre; Lansky, Alexandra J; Fitzgerald, Peter J; Tanajura, Luis Fernando; Feres, Fausto; Staico, Rodolfo; Mattos, Luiz; Abizaid, Andrea; Chaves, Aurea; Centemero, Marinella; Sousa, Amanda G M R; Sousa, J Eduardo; Zaugg, Margo J; Schwartz, Lewis B

    2007-05-15

    The ZoMaxx Coronary Stent System elutes the antiproliferative agent zotarolimus via a biocompatible phosphorylcholine polymer loaded onto a novel, thin, stainless steel stent platform containing an 0.0007-inch inner layer of tantalum that enhances fluoroscopic radiopacity. The objective of this single-arm prospective clinical trial was to assess the safety and performance of the ZoMaxx stent for the treatment of coronary artery stenosis. Forty consecutive patients with ischemic coronary occlusive disease due to single de novo obstructive lesions of native coronary arteries were treated with 3 x 18 mm ZoMaxx stents at the Dante Pazzanese de Cardiologie in Saõ Paulo, Brazil, between April and July 2005. Independent core laboratories analyzed quantitative coronary angiography and intravascular ultrasound results immediately after stent implantation, and after 4 months. The lesion, procedure, and device-deployment success rates were all 100% (40 of 40). There were no major adverse cardiac events during the study. Follow-up quantitative coronary angiography at 4 months revealed in-stent and in-segment late lumen losses of 0.20 +/- 0.35 and 0.17 +/- 0.35 mm, respectively. Follow-up intravascular ultrasound at 4 months revealed 6.5 +/- 6.2% neointimal volume obstruction. There were no instances of late acquired stent incomplete apposition or stent thrombosis. In conclusion, the ZoMaxx Coronary Stent can be safely implanted for the treatment of de novo coronary artery stenosis. The inhibition of neointima formation as measured by follow-up angiography and IVUS after 4 months suggests therapeutic potential for the reduction of restenosis.

  11. Metallic stent implantation in patients with iliac artery occlusion: long-term patency rate and factors related to recurrence

    International Nuclear Information System (INIS)

    Chung, Seok Kyun; Kim, Jae Kyu; Yoon, Woong; Kim, Jeong; Park, Jin Gyoon; Kang, Heoung Keun; Choi, Soo JinNa

    2003-01-01

    To determine the long-term patency rate in 68 patients with iliac artery occlusion who underwent metallic stent implantation, and to analyze the factors related to recurrence. Sixty-eight patients with occlusive disease of the iliac artery underwent implantation of a self-expandable metallic stent. The clinical symptoms were intermittent claudication (n=48), resting pain (n=11), and gangrene (n=9). Stent patency was determined by follow-up angiography and color Doppler imaging, and the cumulative patency rate using the Kaplan-Meier method. Cox's proportional hazard model was used to analyse recurrence-related factors involving clinical symptoms (Fontaine stage), risk factors, and anatomical factors such as lesion location, length, and the development of collaterals. The duration of follow-up varied from 1 day to 73 months (mean, 23.8 months). Arterial occlusion recurred in 16 of 68 patients (23.5%), and the cumulative patency rate was as follows: 95.4% at one month, 93.2% at six months, 80.1% at one year, 73.2% at two years, 68.9% at three years, and 62% at five years. According to a statistical analysis of risk factors, the recurrence (p=0.04) than in those without it, but in patients who smoked, hypertension, DM, and previous cerebrovascular disease were not statistically significant. With regard to anatomical factors, the recurrent rate for lesions involving the external iliac artery was 6.5 times higher (p=0.02) than for those involving the common iliac artery. Variations in the fontaine stage were not statistically significant indicators of recurrence. The recurrence rate after implantation of an iliac artery stent is higher in patients with heart disease than in those without it, and higher for occlusive lesions involving the external iliac artery than for those of the common iliac artery

  12. Outcomes of endoscopic pyloric stenting in malignant gastric outlet obstruction: a retrospective study.

    Science.gov (United States)

    Mansoor, Hala; Yusuf, Muhammed Aasim

    2013-07-19

    Up to 30% of patients with pancreatic cancer and more than 50% of patients with gastric cancer already have incurable disease, with distressing symptoms of gastric outlet obstruction at the time of presentation which require effective palliation. We decided to test the clinical outcomes of endoscopic stent placement in malignant gastric outlet obstruction. In a retrospective single institution-based study, the charts of patients who had self-expandable metal stents placed to alleviate malignant gastric outlet obstruction were reviewed. Charts were reviewed to assess improvement in oral intake according to the Gastric Outlet Obstruction Scoring System (GOOSS), and in order to also evaluate technical success and complications of the procedure. 69 patients with successful stent placement were retrospectively evaluated. Within 7 and 28 days after stent placement respectively, 85.5% and 80% benefited from stent insertion, with an increase in the GOOSS score of > 1. Resumption of soft or low residue diet (GOOSS 2-3) was achieved in 53.6% at day 7 and in 62% of patients at day 28, respectively. Of the patients achieving a GOOSS score of 2-3, 17.3% remained on a soft or low residue diet at 24 weeks or at last follow up, while 46% died. Stent related adverse events occurred in 10 patients (14%), including stent blockade in 7 and stent migration in 3 patients. Endoscopic enteral stenting promptly increases oral intake in the majority of patients with malignant gastric outlet obstruction and is a safe procedure with a low rate of serious complications.

  13. Endothelial Barrier Protein Expression in Biodegradable Polymer Sirolimus-Eluting Versus Durable Polymer Everolimus-Eluting Metallic Stents.

    Science.gov (United States)

    Mori, Hiroyoshi; Cheng, Qi; Lutter, Christoph; Smith, Samantha; Guo, Liang; Kutyna, Matthew; Torii, Sho; Harari, Emanuel; Acampado, Eduardo; Joner, Michael; Kolodgie, Frank D; Virmani, Renu; Finn, Aloke V

    2017-12-11

    This study sought to investigate endothelial coverage and barrier protein expression following stent implantation. Biodegradable polymer drug-eluting stents (BP-DES) have been purported to have biological advantages in vessel healing versus durable polymer DES (DP-DES), although clinical trial data suggest equipoise. Biodegradable polymer-sirolimus-eluting stents (BP-SES), durable polymer-everolimus-eluting stents (DP-EES), and bare-metal stents (BMS) were compared. In the rabbit model (28, 45, and 120 days), stented arteries underwent light microscopic analysis and immunostaining for the presence of vascular endothelium (VE)-cadherin, an endothelial barrier protein, and were subjected to confocal microscopy and scanning electron microscopy. A cell culture study in stented silicone tubes was performed to assess cell proliferation. Light microscopic assessments were similar between BP-SES and DP-EES. BMS showed nearly complete expression of VE-cadherin at 28 days, whereas both DES showed significantly less with results favoring BP-SES versus DP-EES (39% coverage in BP-SES, 22% in DP-EES, 95% in BMS). Endothelial cell morphologic patterns differed according to stent type with BMS showing a spindle-like shape, DP-EES a cobblestone pattern, and BP-SES a shape in between. VE-cadherin-negative areas showed greater surface monocytes regardless of type of stent. Cell proliferation was suppressed in both DES with numerically less suppression in BP-SES versus DP-EES. This is the first study to examine VE-cadherin expression after DES. All DES demonstrated deficient barrier expression relative to BMS with results favoring BP-SES versus DP-EES. These findings may have important implications for the development of neoatherosclerosis in different stent types. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. Endoscopic suturing for the prevention of stent migration in benign upper gastrointestinal conditions: a comparative multicenter study.

    Science.gov (United States)

    Ngamruengphong, Saowanee; Sharaiha, Reem Z; Sethi, Amrita; Siddiqui, Ali A; DiMaio, Christopher J; Gonzalez, Susana; Im, Jennifer; Rogart, Jason N; Jagroop, Sophia; Widmer, Jessica; Hasan, Raza Abbas; Laique, Sobia; Gonda, Tamas; Poneros, John; Desai, Amit; Tyberg, Amy; Kumbhari, Vivek; El Zein, Mohamad; Abdelgelil, Ahmed; Besharati, Sepideh; Hernaez, Ruben; Okolo, Patrick I; Singh, Vikesh; Kalloo, Anthony N; Kahaleh, Michel; Khashab, Mouen A

    2016-09-01

    Fully covered self-expandable metal stents (FCSEMSs) have increasingly been used in benign upper gastrointestinal (UGI) conditions; however, stent migration remains a major limitation. Endoscopic suture fixation (ESF) may prevent stent migration. The aims of this study were to compare the frequency of stent migration in patients who received endoscopic suturing for stent fixation (ESF group) compared with those who did not (NSF group) and to assess the impact of ESF on clinical outcome. This was a retrospective study of patients who underwent FCSEMS placement for benign UGI diseases. Patients were divided into either the NSF or ESF group. Outcome variables, including stent migration, clinical success (resolution of underlying pathology), and adverse events, were compared. A total of 125 patients (44 in ESF group, 81 in NSF group; 56 benign strictures, 69 leaks/fistulas/perforations) underwent 224 stenting procedures. Stent migration was significantly more common in the NSF group (33 % vs. 16 %; P = 0.03). Time to stent migration was longer in the ESF group (P = 0.02). ESF appeared to protect against stent migration in patients with a history of stent migration (adjusted odds ratio [OR] 0.09; P = 0.002). ESF was also significantly associated with a higher rate of clinical success (60 % vs. 38 %; P = 0.03). Rates of adverse events were similar between the two groups. Endoscopic suturing for stent fixation is safe and associated with a decreased migration rate, particularly in patients with a prior history of stent migration. It may also improve clinical response, likely because of the reduction in stent migration. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Feasibility, safety, and outcomes of a single-step endoscopic ultrasonography-guided drainage of pancreatic fluid collections without fluoroscopy using a novel electrocautery-enhanced lumen-apposing, self-expanding metal stent

    Science.gov (United States)

    Yoo, Joseph; Yan, Linda; Hasan, Raza; Somalya, Saana; Nieto, Jose; Siddiqui, Ali A.

    2017-01-01

    Background and Objectives: There are currently limited data available regarding the safety of endoscopic ultrasound (EUS)-guided drainage of pancreatic fluid collections (PFCs) using the lumen-apposing metal stent without fluoroscopic guidance. This study aims to evaluate clinical outcomes and safety of EUS-guided drainage of PFC using the electrocautery-enhanced lumen-apposing metal stents (EC-LAMSs) without fluoroscopic guidance. Methods: We conducted a retrospective study on patients with symptomatic PFC who underwent EUS-guided drainage using EC-LAMS without fluoroscopy. All patients were followed clinically until resolution of their PFC. Technical success (successful placement of EC-LAMS), number of patients who achieved complete resolution of PFC without additional intervention and adverse events were noted. Results: We evaluated 25 patients, including three with pancreatic pseudocysts and 22 with walled-off necrosis (WON). The etiology of the patient's pancreatitis was gallstones (42%), alcohol (27%), and other causes (31%). The mean cyst size was 82 mm (range, 60–170 mm). The indications for endoscopic drainage were abdominal pain, infected WON, or gastric outlet obstruction. Technical success with placement of the EC-LAMS was achieved in all 25 patients. There were no procedure-related complications. The mean patient follow-up was 7.8 months. PFCs resolved in 24 (96%) patients; the one failure was in a patient with WON. Stent occlusion was seen in one patient. There was a spontaneous migration of one stent into the enteral lumen after resolution of WONs. The EC-LAMS were successfully removed using a snare in all the remaining patients. The median number of endoscopy sessions to achieve PFCs resolution was 2 (range, 2–6). Conclusions: Single-step EUS-guided drainage of PFCs without fluoroscopic guidance using the novel EC-LAMS is a safe and effective endoscopic technique for drainage of PFCs with excellent technical and clinical success rates and no

  16. Outcomes of polytetrafluoroethylene-covered stent versus bare-metal stent in the primary treatment of severe iliac artery obstructive lesions.

    Science.gov (United States)

    Piazza, Michele; Squizzato, Francesco; Spolverato, Gaya; Milan, Luca; Bonvini, Stefano; Menegolo, Mirko; Grego, Franco; Antonello, Michele

    2015-11-01

    This study compared early and midterm outcomes of polytetrafluoroethylene-covered stents (CSs) vs bare-metal stents (BMSs) in the primary treatment of severe TransAtlantic Inter-Society Consensus for the Management of Peripheral Arterial Disease (TASC II) C and D iliac artery obstructive lesions. Between January 2009 and June 2014, 128 patients underwent stenting of 167 iliac arteries; CSs were implanted in 82 iliac arteries (49%) and BMSs in 85 (51%). All patients were prospectively enrolled in a dedicated database. Thirty-day outcomes, mid-term patency, limb salvage, and survival were compared, and follow-up results were analyzed with Kaplan-Meier curves. Clinical presentation, lesion site, extension, and laterality were evaluated for their association with patency in the two groups using multiple logistic regressions. Patients were a mean age of 70 ± 10.3 years, The Society for Vascular Surgery comorbidity score was 0.89 ± 0.57, with no differences after stratification by CS and BMS (P = .17). Iliac lesions were classified by limb as TASC II C in 86 (51%) and D in 81 (49%). Comparing CS and BMS, technical success was 99% in both groups (P = 1.0); the 30-day cumulative surgical complications rate (7.3% vs 4.7%; P = .53), mortality (1.8% vs 0%; P = .45), and morbidity (1.8% vs 1.4%; P = .99) were equivalent. At 24 months (average 22 months; range, 30 days-56 months), primary patency of CS vs BMS was similar (93% vs 80%; P = .14), and this finding was maintained after stratification by TASC II C (97% vs 93%; P = .59) and D (88% vs 61%; P = .07); secondary patency was 98% vs 92% (P = .22), and limb salvage was 99% and 95% (P = .35) respectively. Multivariate analysis indicated that BMS in long-segment stenosis involving the common and external iliac arteries was a negative predictor of patency (odds ratio, 0.16; 95% confidence interval, 0.04-0.62; P = .007); within this subgroup of TASC II D lesions, primary patency at 24 months was significantly

  17. Efficacy of a dexamethasone-eluting nitinol stent on the inhibition of pseudointimal hyperplasia in a transjugular intrahepatic portosystemic shunt: an experimental study in a swine model

    International Nuclear Information System (INIS)

    Seo, Tae Seok; Oh, Joo Hyeogn; Park, Young Koo; Song, Ho Young; Park, Sang Joon; Yuk, Sun Hong

    2005-01-01

    We wanted to evaluate the feasibility and efficacy of using a dexamethasone (DM)-eluting nitinol stent to inhibit the pseudointimal hyperplasia following stent placement in the transjugular intrahepatic portosystemic shunt tract (TIPS) of a swine. Fifteen stents were constructed using 0.15 mm-thick nitinol wire; they were 60 mm in length and 10 mm in diameter. The metallic stents were then classified into three types; type 1 and 2 was coated with the mixture of 12% and 20%, respectively, of DM solution and polyurethane (PU), while type 3 was a bare stent that was used for control study. In fifteen swine, each type of stent was implanted in the TIPS tract of 5 swine, and each animal was sacrificed 2 weeks after TIPS creation. The proliferation of the pseudointima was evaluated both on follow-up portogram and pathologic examination. One TIPS case, using the type 1 stent, and two TIPS cases, using the type 2 stent, maintained their luminal patency while the others were all occluded. On the histopathologic analysis, the mean of the maximum pseudointimal hyperplasia was expressed as the percentage of the stent radius that was patent, and these values were 51.2%, 50% and 76% for the type 1, 2, and 3 stents, respectively. The DM-eluting stent showed a tendency to reduce the development of pseudointimal hyperplasia in the TIPS tract of a swine model with induced-portal hypertension

  18. Network meta-analysis of balloon angioplasty, nondrug metal stent, drug-eluting balloon, and drug-eluting stent for treatment of infrapopliteal artery occlusive disease.

    Science.gov (United States)

    Xiao, Yaowen; Chen, Zhong; Yang, Yaoguo; Kou, Lei

    2016-01-01

    We aimed to conduct a network meta-analysis of mixed treatments for the infrapopliteal artery occlusive disease. We searched randomized controlled trials (RCTs) regarding balloon angioplasty (BA), nondrug metal stent (NDMS), drug-eluting balloon (DEB), or drug-eluting stent (DES) in PubMed, Embase, CENTRAL, Ovid, Sinomed, and other relevant websites. We selected and assessed the trials that met the inclusion criteria and conducted a network meta-analysis using the ADDIS software. We included 11 relevant trials. We analyzed data of 1322 patients with infrapopliteal artery occlusive disease, of which 351 were in the NDMS vs. DES trials, 231 in the NDMS vs. BA trials, 490 in the BA vs. DEB trials, 50 in the DEB vs. DES trials, and 200 in the BA vs. DES trials. The network meta-analysis indicated that with NDMS as the reference, DES had a better result with respect to restenosis (odds ratio [OR], 5.16; 95% credible interval [CI], 1.58-18.41; probability of the best treatment, 84%) and amputation (OR, 2.50; 95% CI, 0.81-7.11; probability of the best treatment, 61%) and DEB had a better result with respect to target lesion revascularization (TLR; OR, 3.74; 95% CI, 0.78-17.05; probability of the best treatment, 57%). Moreover, with BA as the reference, NDMS had a better result with respect to technical success (OR, 0.10; 95% CI, 0.00-1.15; probability of the best treatment, 86%). Our meta-analysis revealed that DES is a better treatment with respect to short-term patency and limb salvage rate, NMDS may provide a better technical success, and DEB and DES are good choices for reducing revascularization.

  19. Metallic Limus-Eluting Stents Abluminally Coated with Biodegradable Polymers: Angiographic and Clinical Comparison of a Novel Ultra-Thin Sirolimus Stent Versus Biolimus Stent in the DESTINY Randomized Trial.

    Science.gov (United States)

    Lemos, Pedro A; Abizaid, Alexandre A C; Meireles, George C; Sarmento-Leite, Rogério; Prudente, Mauricio; Cantarelli, Marcelo; Dourado, Adriano D; Mariani, Jose; Perin, Marco A; Costantini, Costantino; Costa, Ricardo A; Costa, José Ribamar; Chamie, Daniel; Campos, Carlos A; Ribeiro, Expedito

    2015-12-01

    To evaluate the outcomes of patients treated with a new drug-eluting stent formulation with low doses of sirolimus, built in an ultra-thin-strut platform coated with biodegradable abluminal coating. This study is a randomized trial that tested the main hypothesis that the angiographic late lumen loss of the novel sirolimus-eluting stent is noninferior compared with commercially available biolimus-eluting stent. A final study population comprising 170 patients with one or two de novo lesions was randomized in the ratio 2:1 for sirolimus-eluting stent or biolimus-eluting stent, respectively. The primary endpoint was 9-month angiographic in-stent late lumen loss. Adverse clinical events were prospectively collected for 1 year. After 9 months, the novel sirolimus-eluting stent was shown noninferior compared with the biolimus stent for the primary endpoint (angiographic in-stent late lumen loss: 0.20 ± 0.29 mm vs. 0.15 ± 0.20 mm, respectively; P value for noninferiority <0.001). The 1-year incidence of death, myocardial infarction, repeat revascularization, and stent thrombosis remained low and not significantly different between the groups. The present randomized trial demonstrates that the tested novel sirolimus-eluting stent was angiographically noninferior in comparison with a last-generation biolimus-eluting stent. © 2015 John Wiley & Sons Ltd.

  20. Prospective, multi-center evaluation of a silicon carbide coated cobalt chromium bare metal stent for percutaneous coronary interventions: Two-year results of the ENERGY Registry

    Energy Technology Data Exchange (ETDEWEB)

    Erbel, Raimund, E-mail: erbel@uk-essen.de [Department of Cardiology, University of Duisburg-Essen, Essen (Germany); Eggebrecht, Holger [Cardioangiological Center Bethanien (CCB), Frankfurt (Germany); Roguin, Ariel [Department of Cardiology, Rambam Medical Center, Haifa (Israel); Schroeder, Erwin [Division of Cardiovascular Medicine, Cliniques Universitaires de Mont-Godinne, Yvoir (Belgium); Philipp, Sebastian [Department Internal Medicine/Cardiology, Elbe Klinikum Stade, Stade (Germany); Heitzer, Thomas [Department of Cardiology, Heart Center Dortmund, Dortmund (Germany); Schwacke, Harald [Department of Internal Medicine, Diakonissen-Stiftungs- Krankenhaus Speyer (Germany); Ayzenberg, Oded [The Heart Institute, Kaplan Medical Center, Rehovot (Israel); Serra, Antonio [Servicio de Cardiología, Hospital de la Santa Creu i Sant Pau, Barcelona, España (Spain); Delarche, Nicolas [Cardiology unit, Pau General Hospital, Pau (France); Luchner, Andreas [Department of Internal Medicine/Cardiology, Universitätsklinikum Regensburg (Germany); Slagboom, Ton [Department of Cardiology, Onze Lieve Vrouwe Gasthuis, Amsterdam (Netherlands)

    2014-11-15

    Background: Novel bare metal stents with improved stent design may become a viable alternative to drug-eluting stents in certain patient groups, particularly, when long-term dual antiplatelet therapy should be avoided. Purpose: The ENERGY registry aimed to assess the safety and benefits of a cobalt–chromium thin strut bare metal stent with a passive coating in a large series of patients under real-world conditions. Methods and materials: This prospective registry recruited 1016 patients with 1074 lesions in 48 centers from April to November 2010. The primary endpoint was the rate of major adverse cardiac events (MACEs), a composite of cardiac death, myocardial infarction and clinically driven target lesion revascularization. Results: More than half of the lesions (61.0%) were type A/B1 lesions, mean lesion length was 14.5 ± 6.5 mm and mean reference vessel diameter 3.2 ± 0.5 mm. MACE rates at 6, 12 and 24 months were 4.9%, 8.1% and 9.4%, target lesion revascularization rates 2.8%, 4.9% and 5.4% and definite stent thrombosis rates 0.5%, 0.6% and 0.6%. Subgroups showed significant differences in baseline and procedural characteristics which did not translate into significantly different clinical outcomes. Specifically, MACE rates at 24 months were 13.5% in diabetics, 8.6% in small stents and 9.6% in acute coronary syndrome patients. Conclusion: The population of ENERGY reflects real-world conditions with bare metal stents being mainly used in simple lesions. In this setting, percutaneous coronary intervention using a cobalt–chromium thin strut bare metal stent with a passive coating showed very good results up to 24 months. (ClinicalTrials.gov:NCT01056120) Summary for annotated table of contents: The ENERGY international registry evaluated the safety and benefits of a cobalt–chromium thin strut bare metal stent with passive coating in 1016 patients under real-world conditions until 2 years. Results were encouraging with a low composite rate of cardiac death

  1. Prospective, multi-center evaluation of a silicon carbide coated cobalt chromium bare metal stent for percutaneous coronary interventions: Two-year results of the ENERGY Registry

    International Nuclear Information System (INIS)

    Erbel, Raimund; Eggebrecht, Holger; Roguin, Ariel; Schroeder, Erwin; Philipp, Sebastian; Heitzer, Thomas; Schwacke, Harald; Ayzenberg, Oded; Serra, Antonio; Delarche, Nicolas; Luchner, Andreas; Slagboom, Ton

    2014-01-01

    Background: Novel bare metal stents with improved stent design may become a viable alternative to drug-eluting stents in certain patient groups, particularly, when long-term dual antiplatelet therapy should be avoided. Purpose: The ENERGY registry aimed to assess the safety and benefits of a cobalt–chromium thin strut bare metal stent with a passive coating in a large series of patients under real-world conditions. Methods and materials: This prospective registry recruited 1016 patients with 1074 lesions in 48 centers from April to November 2010. The primary endpoint was the rate of major adverse cardiac events (MACEs), a composite of cardiac death, myocardial infarction and clinically driven target lesion revascularization. Results: More than half of the lesions (61.0%) were type A/B1 lesions, mean lesion length was 14.5 ± 6.5 mm and mean reference vessel diameter 3.2 ± 0.5 mm. MACE rates at 6, 12 and 24 months were 4.9%, 8.1% and 9.4%, target lesion revascularization rates 2.8%, 4.9% and 5.4% and definite stent thrombosis rates 0.5%, 0.6% and 0.6%. Subgroups showed significant differences in baseline and procedural characteristics which did not translate into significantly different clinical outcomes. Specifically, MACE rates at 24 months were 13.5% in diabetics, 8.6% in small stents and 9.6% in acute coronary syndrome patients. Conclusion: The population of ENERGY reflects real-world conditions with bare metal stents being mainly used in simple lesions. In this setting, percutaneous coronary intervention using a cobalt–chromium thin strut bare metal stent with a passive coating showed very good results up to 24 months. (ClinicalTrials.gov:NCT01056120) Summary for annotated table of contents: The ENERGY international registry evaluated the safety and benefits of a cobalt–chromium thin strut bare metal stent with passive coating in 1016 patients under real-world conditions until 2 years. Results were encouraging with a low composite rate of cardiac death

  2. Five-year outcomes for first generation drug-eluting stents versus bare-metal stents in patients with ST-segment elevation myocardial infarction: a meta-analysis of randomised controlled trials.

    Science.gov (United States)

    Zheng, Fei; Xing, Shanshan; Gong, Zushun; Xing, Qichong

    2014-06-01

    Drug-eluting stent (DES) implantation has been proved more effective compared with bare-metal stent (BMS) implantation for ST-segment elevation myocardial infarction (STEMI) within medium follow up. However, limited information is available on the long-term safety and efficacy of DES. We performed a meta-analysis of randomised controlled trials (RCT) comparing DES with BMS in patients with STEMI at long-term follow up, defined as five years or more. The clinical end points were target vessel revascularisation (TVR), death, recurrent myocardial infarction (MI), stent thrombosis and very late stent thrombosis. We calculated the pooled estimate based on a fixed-effects model using odds ratio (OR) for rare events. Four RCT were included, with a total of 1414 patients enrolled. Up to five years, DES showed a significant reduction in TVR (OR, 0.55; 95% confidence interval [CI], 0.55-0.77; P = 0.0005), but an increase in very late stent thrombosis (OR, 3.03; 95% CI, 1.28-7.18; P = 0.01), without increasing mortality (OR, 0.85; 95% CI, 0.59-1.20; P = 0.35), recurrent MI (OR, 1.05; 95% CI, 0.69-1.60; P = 0.80), and overall stent thrombosis (OR, 1.10; 95% CI, 0.66-1.82; P = 0.72). At long-term follow-up, primary percutaneous coronary intervention with DES improved efficacy, without reducing overall safety. However, a trade-off must be made between the reduction of reintervention with DES and an increase in very late stent thrombosis. Crown Copyright © 2014. Published by Elsevier B.V. All rights reserved.

  3. Endoscopic Ultrasound-guided Drainage of Walled-off Necrosis in Children With Fully Covered Self-expanding Metal Stents.

    Science.gov (United States)

    Nabi, Zaheer; Lakhtakia, Sundeep; Basha, Jahangeer; Chavan, Radhika; Ramchandani, Mohan; Gupta, Rajesh; Kalapala, Rakesh; Darisetty, Santosh; Talukdar, Rupjyoti; Reddy, Duvuur Nageshwar

    2017-04-01

    Endoscopic ultrasound (EUS)-guided drainage with fully covered self-expanding metallic stents (FCSEMS) has been successfully used in adult patients. The utility of FCSEMS in children with walled-off necrosis (WON) is, however, unknown. The aim of present study was to evaluate the feasibility, safety, and efficacy of EUS drainage of WON using FCSEMS in children. We retrospectively evaluated the data of children (18 years or younger) who underwent EUS drainage of WON using FCSEMS at our institution. All FCSEMS were removed between 1 and 3 months. Feasibility, safety, and efficacy were analysed. Twenty-one children (20 boys, mean age 14.9 ± 2.34 years, range 9-18 years) underwent EUS-guided drainage of WON with FCSEMS. The median size of WON was 88 mm (55-148 mm). The median interval between onset of acute pancreatitis and EUS guided drainage was 58 days (range 30-288 days). The technical and clinical success rates were 100% and 95%, respectively. Nasocystic tube was placed in 3 children for lavage. Endoscopic necrosectomy was not required in any of the children. There were no major complications. Minor complications included bleeding (2), stent migration (1), and difficulty in removal of stent (1). After a median follow-up of 360 days (range: 30-1020 days), there was 1 recurrence of WON. EUS drainage of WON using specially designed FCSEMS is safe and efficacious in children. The utility of FCSEMS in children should be further explored and compared with plastic stents.

  4. Safety and efficacy of biodegradable drug-eluting vs. bare metal stents: a meta-analysis from randomized trials.

    Science.gov (United States)

    Yin, Yangguang; Zhang, Yao; Zhao, Xiaohui

    2014-01-01

    Biodegradable polymeric coatings have been proposed as a promising strategy to enhance biocompatibility and improve the delayed healing in the vessel. However, the efficacy and safety of biodegradable polymer drug-eluting stents (BP-DES) vs. bare metal stents (BMS) are unknown. The aim of this study was to perform a meta-analysis of randomized controlled trials (RCTs) comparing the outcomes of BP-DES vs. BMS. PubMed, Embase, and Cochrane Central Register of Controlled Trials (CENTRAL) were searched for randomized clinical trials, until December 2013, that compared any of approved BP-DES and BMS. Efficacy endpoints were target-vessel revascularization (TVR), target-lesion revascularization (TLR) and in-stent late loss (ISLL). Safety endpoints were death, myocardial infarction (MI), definite stent thrombosis (DST). The meta-analysis included 7 RCTs with 2,409 patients. As compared with BMS, there was a significantly reduced TVR (OR [95% CI] = 0.37 [0.28-0.50]), ISLL (OR [95% CI] = -0.41 [-0.48-0.34]) and TLR (OR [95% CI] = 0.38 [0.27-0.52]) in BP-DES patients. However, there were no difference for safety outcomes between BP-DES and BMS. BP-DES is more effective in reducing ISLL, TVR and TLR, as safe as standard BMS with regard to death, ST and MI. Further large RCTs with long-term follow-up are warranted to better define the relative merits of BP-DES.

  5. Clinical outcome after primary percutaneous coronary intervention with drug-eluting and bare metal stents in patients with ST-segment elevation myocardial infarction

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Maeng, Michael; Thayssen, Per

    2008-01-01

    BACKGROUND: The use of drug-eluting stents (DESs) versus bare metal stents (BMSs) in primary percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction is a matter of debate. Therefore, we examined the risk of target lesion revascularization (TLR), stent thrombosis......, myocardial infarction, and death after the implantation of DES or BMS in primary PCI patients in Western Denmark. METHODS AND RESULTS: A total of 3756 consecutive patients with ST-segment elevation myocardial infarction treated with primary PCI and stent implantation, recorded in the Western Denmark Heart...... RR=1.13; 95% CI=0.81 to 1.59; P=0.47). All-cause 2-year mortality was 7.8% in the DES group and 11.4% in BMS group (P7.2% in the DES group and 8.7% in the BMS group (P=0.09; adjusted RR...

  6. Stent thrombosis caused by metal allergy complicated by protein S deficiency and heparin-induced thrombocytopenia: a case report and review of the literature.

    Science.gov (United States)

    Konishi, Takao; Yamamoto, Tadashi; Funayama, Naohiro; Yamaguchi, Beni; Sakurai, Seiichiro; Nishihara, Hiroshi; Yamazaki, Koko; Kashiwagi, Yusuke; Sasa, Yasuki; Gima, Mitsuru; Tanaka, Hideichi; Hotta, Daisuke; Kikuchi, Kenjiro

    2015-01-01

    A 43-year-old woman recipient of a bare metal coronary stent during an acute anterior myocardial infarction was repeatedly hospitalized with recurrent stent thrombosis (ST) over the following 3 years. Emergent coronary angiography showed a thrombus in the in-stent segment of the proximal left anterior descending artery. We repeatedly aspirated the thrombus, which immediately reformed multiple times. The discontinuation of heparin and administration of thrombolytics and argatroban, followed by repeated balloon dilatations, ended the formation of new thrombi. The patient was found to be allergic to nickel, protein S deficient and carrier of heparin-induced thrombocytopenia antibody. We discuss this case in the context of a) literature pertaining to acute coronary syndromes in the young, and b) the detailed investigations needed to identify thrombotic risk factors. Steroids may be effective to prevent recurrent ST caused by stent allergy.

  7. Tracheal stenting under flexible bronchoscopy for large tracheoesophageal malignant lymphadenopathy

    Science.gov (United States)

    Ayub, Irfan Ismail; Kannan, Kalaichelvi; Dhenesh, R; Thiagarajan, Anand

    2017-01-01

    A 67-year-old man with poorly controlled chronic obstructive pulmonary disease presented with progressive dysphagia and was diagnosed with locally advanced carcinoma of the esophagus. Positron emission tomography-computed tomography staging showed mediastinal lymphadenopathy including a large lymph node in the tracheoesophageal groove with moderate tracheal compression. He was advised chemoradiotherapy but was reluctant to proceed with the same. He developed stridor 2 months later and repeat imaging showed increased size of the tracheoesophageal lymph node with critical airway narrowing. Since he was not fit for general anesthesia, he was subjected to tracheal stenting with self-expandable metal stent under flexible bronchoscopy. Following stent placement, there was relief of dyspnea, and stridor and the patient was discharged. PMID:28474657

  8. Stent Fracture after Everolimus-Eluting Stent Implantation

    Directory of Open Access Journals (Sweden)

    Ali S. Almasood

    2011-01-01

    Full Text Available Compared with bare-metal stents, drug-eluting stents (DES have greatly reduced the risk of in-stent restenosis (ISR by inhibiting neointimal growth. Nevertheless, DES are still prone to device failure, which may lead to cardiac events. Recently, stent fracture (SF has emerged as a potential mechanism of DES failure that is associated with ISR. Stent fracture is strongly related to stent type, and prior reports suggest that deployment of sirolimus eluting stents (SES may be associated with a higher risk of SF compared to other DES. Everolimus eluting stents (EESs represent a new generation of DES with promising results. The occurrence of SF with EES has not been well established. The present paper describes two cases of EES fracture associated with ISR.

  9. The evaluation of primary stenting of sirolimus-eluting versus bare-metal stents in the treatment of atherosclerotic lesions of crural arteries

    International Nuclear Information System (INIS)

    Falkowski, Aleksander; Wilk, Grazyna; Poncyljusz, Wojciech; Szczerbo-Trojanowska, Malgorzata

    2009-01-01

    A comparison was made of sirolimus-eluting stents and bare stents as an effective means of treatment of stenosis in crural arteries. Patients were randomly divided into two groups: (1) patients treated with sirolimus-eluting stents and (2) patients treated with bare stents. Each group consisted of 25 patients, and every patient had one stent implanted. All patients showed symptoms of ischemia of the peripheral arteries, classified according to the Rutherford scale into categories 3, 4, and 5. All patients were examined 24 h before and 24 h and 6 months after the intervention. The results were analyzed according to clinical, hemodynamic, and angiographic criteria. Technically, the procedure was successful in 100% of cases, and both groups presented an equal improvement in clinical and hemodynamic parameters. The follow-up angiographic examination demonstrated a significantly lower rate of restenosis among the sirolimus-eluting stent group (4, 16%) versus the bare stent group (19, 76%) (p < 0.001), with lower target lesion revascularization in 3 (12%) versus 14 (56%) (p < 0.05), respectively. Quantitative angiography demonstrated that all variables used to assess restenosis were superior for sirolimus-eluting stents 6 months after intervention: late lumen loss 0.46 ± 0.72 versus 1.70 ± 0.94 (p < 0.001) and minimal lumen diameter 2.25 ± 0.82 versus 0.99 ± 1.08 (p < 0.001). Results of this study reveal that the use of sirolimus-eluting stents decreases the risk of restenosis in comparison to standard stents. (orig.)

  10. The evaluation of primary stenting of sirolimus-eluting versus bare-metal stents in the treatment of atherosclerotic lesions of crural arteries

    Energy Technology Data Exchange (ETDEWEB)

    Falkowski, Aleksander; Wilk, Grazyna [Pomeranian Medical University of Szczecin, Departament of General and Dental Diagnostic Imaging, Szczecin (Poland); Poncyljusz, Wojciech [Pomeranian Medical University of Szczecin, Departament of Diagnostic Imaging and Interventional Radiology, Szczecin (Poland); Szczerbo-Trojanowska, Malgorzata [Medical University of Lublin, Department of Interventional Radiology and Neuroradiology, Lublin (Poland)

    2009-04-15

    A comparison was made of sirolimus-eluting stents and bare stents as an effective means of treatment of stenosis in crural arteries. Patients were randomly divided into two groups: (1) patients treated with sirolimus-eluting stents and (2) patients treated with bare stents. Each group consisted of 25 patients, and every patient had one stent implanted. All patients showed symptoms of ischemia of the peripheral arteries, classified according to the Rutherford scale into categories 3, 4, and 5. All patients were examined 24 h before and 24 h and 6 months after the intervention. The results were analyzed according to clinical, hemodynamic, and angiographic criteria. Technically, the procedure was successful in 100% of cases, and both groups presented an equal improvement in clinical and hemodynamic parameters. The follow-up angiographic examination demonstrated a significantly lower rate of restenosis among the sirolimus-eluting stent group (4, 16%) versus the bare stent group (19, 76%) (p < 0.001), with lower target lesion revascularization in 3 (12%) versus 14 (56%) (p < 0.05), respectively. Quantitative angiography demonstrated that all variables used to assess restenosis were superior for sirolimus-eluting stents 6 months after intervention: late lumen loss 0.46 {+-} 0.72 versus 1.70 {+-} 0.94 (p < 0.001) and minimal lumen diameter 2.25 {+-} 0.82 versus 0.99 {+-} 1.08 (p < 0.001). Results of this study reveal that the use of sirolimus-eluting stents decreases the risk of restenosis in comparison to standard stents. (orig.)

  11. Propensity score matched lesion-based comparison of long-term clinical and angiographic outcomes after placement of sirolimus (Cypher Bx Velocity) and paclitaxel (TAXUS Express)-eluting stents for de novo native coronary stenosis.

    Science.gov (United States)

    Nakano, Yosuke; Ishikawa, Tetsuya; Hino, Shoryoku; Mutoh, Makoto

    2014-04-01

    Long-term clinical and angiographic outcomes after sirolimus (SES: Cypher Bx Velocity) and paclitaxel (PES: TAXUS Express)-eluting stent implantation were firstly compared in Japan. During PES-available period from May 2007 to February 2009, 1068 nonrandomized consecutive de novo native coronary lesions treated either with a PES (682 lesions) or SES were enrolled in this study, and a retrospective examination was conducted in April 2013. During that interval, the use ratio of drug-eluting stent (i.e. SES plus PES) was 94.2 %. By adjusting the baselines with a propensity score matching analysis produced 383 lesions in each arm, the incidence of the clinical endpoint (1500-day cardiac death, nonfatal recurrent myocardial infarction, and definite stent thrombosis) after placement of SES (2.1 %; mean follow-up, 1400 ± 290 days) was not significantly different from that in the PES group (2.6 %; 1394 ± 325 days, p = 0.637). SES did not relate to the clinical endpoint (hazard ratio 1.04; 95 % CI 0.29-3.76; p = 0.949). In the baseline-adjusted angiographic followed up lesions (n = 234 in each arm), the incidence of binary restenosis (percent diameter stenosis [%DS] >50 %) in the SES group (12.0 %; mean follow-up, 477 ± 281 days) was not significantly different from that in the PES group (14.5 %; 497 ± 341 days, p = 0.431). SES did not relate to binary restenosis (Odds ratio 0.73; 95 % CI 0.40-1.32; p = 0.295). In conclusion, the present propensity score matched lesion-based analysis firstly showed the statistical equivalent long-term clinical and angiographic outcomes after either SES or PES placement for de novo native coronary lesion in Japanese patients in a daily practice environment.

  12. [Metal self-expanding stents for malignant obstruction of stomach outlet and duodenum].

    Science.gov (United States)

    Shabunin, A V; Lebedev, S S; Chechenin, G M; Barinov, Yu V; Sidorova, Yu V; Bagateliya, Z A; Vardanyan, A V; Dolidze, D D

    To compare different types of self-expanding stents (partially coated or uncovered) for malignant pyloroduodenal obstruction (MPDO). 89 MPDO patients underwent stenting at the Botkin City Hospital (Moscow) for the period 2008-2016. The causes of malignant obstruction were: stomach cancer - 53 (59.5%), pancreatic cancer - 31 (34.8%), compression by retroperitoneal lymph nodes - 3 (3.4%), duodenal cancer - 2 (2.2%). Patients were divided into two homogeneous groups. In group 1 (32 patients) partially coated stents were used, in group 2 (57 patients) - uncovered stents. Mean age was 68.3±6.2 and 64.3±5.7 years in both groups respectively; male/female ratio 18/14 in group 1, 32/25 in group 2. Length of stricture was 51±5.1 mm in group 1, 48±4.8 mm in group 2. GOOSS score in group 1: 0-8, 1-13, 2-11, 3-0, in group 2 0-14, 1-25, 2-18, 3-0 (p=0.03). Technical success was achieved in 32 patients of group 1 (100%) and in 57 patients of group 2 (100%). There were no procedure-associated complications and mortality. Clinical success was observed in 29 (90.6%) patients of group 1 and in 50 (87.7%) patients of group 2. GOOSS score of group 1: 0-8, 1-8, 2-10, 3-12, group 2: 0-3, 1-15, 2-19, 3-20. There were 3 distal dislocations of the stent within 1 - days in group 1, in group 2 dislocations were absent. Postoperative chemotherapy was prescribed in 20 (62.5%) patients of group 1 and 38 (66.7%) patients of group 2 (p=0.08). 27 patients of group 1 and 49 patients of group 2 died due to progression of the disease, others are under observation. Mean life expectancy: group 1 (18 patients - 50 days, 9 patients - 100 days, 5 patients were alive by the moment of study); group 2 (32 patients - 50 days, 100 days - 17 patients, 8 patients were alive by the moment of study). 3 patients (9.4%) in group 1 and 7 (12.3%) patients in group 2 had stent dysfunction (p=0.02). Mean period of partially covered stent function was 138±3.9 days, uncovered stent - 96±4.8 days (р=0.003). Our study

  13. Safety and efficacy of second-generation drug-eluting stents compared with bare-metal stents: An updated meta-analysis and regression of 9 randomized clinical trials.

    Science.gov (United States)

    Mahmoud, Ahmed N; Shah, Nikhil H; Elgendy, Islam Y; Agarwal, Nayan; Elgendy, Akram Y; Mentias, Amgad; Barakat, Amr F; Mahtta, Dhruv; David Anderson, R; Bavry, Anthony A

    2018-01-01

    The efficacy of second-generation drug-eluting stents (DES; eg, everolimus and zotarolimus) compared with bare-metal stents (BMS) in patients undergoing percutaneous coronary intervention was challenged recently by new evidence from large clinical trials. Thus, we aimed to conduct an updated systematic review and meta-analysis of randomized clinical trials (RCTs) evaluating the efficacy and safety of second-generation DES compared with BMS. Electronic databases were systematically searched for all RCTs comparing second-generation DES with BMS and reporting clinical outcomes. The primary efficacy outcome was major adverse cardiac events (MACE); the primary safety outcome was definite stent thrombosis. The DerSimonian and Laird method was used for estimation of summary risk ratios (RR). A total of 9 trials involving 17 682 patients were included in the final analysis. Compared with BMS, second-generation DES were associated with decreased incidence of MACE (RR: 0.78, 95% confidence interval [CI]: 0.69-0.88), driven by the decreased incidence of myocardial infarction (MI) (RR: 0.67, 95% CI: 0.48-0.95), target-lesion revascularization (RR: 0.47, 95% CI: 0.42-0.53), definite stent thrombosis (RR: 0.57, 95% CI: 0.41-0.78), and definite/probable stent thrombosis (RR: 0.54, 95% CI: 0.38-0.80). The incidence of all-cause mortality was similar between groups (RR: 0.94, 95% CI: 0.79-1.10). Meta-regression showed lower incidences of MI with DES implantation in elderly and diabetic patients (P = 0.026 and P DES appear to be associated with a lower incidence of MACE, mainly driven by lower rates of target-lesion revascularization, MI, and stent thrombosis. However, all-cause mortality appears similar between groups. © 2018 Wiley Periodicals, Inc.

  14. The sirolimus-eluting Cypher Select coronary stent for the treatment of bare-metal and drug-eluting stent restenosis: insights from the e-SELECT (Multicenter Post-Market Surveillance) registry.

    Science.gov (United States)

    Abizaid, Alexandre; Costa, J Ribamar; Banning, Adrian; Bartorelli, Antonio L; Dzavik, Vladimir; Ellis, Stephen; Gao, Runlin; Holmes, David R; Jeong, Muyng Ho; Legrand, Victor; Neumann, Franz-Josef; Nyakern, Maria; Orlick, Amy; Spaulding, Christian; Worthley, Stephen; Urban, Philip M

    2012-01-01

    This study sought to compare the 1-year safety and efficacy of Cypher Select or Cypher Select Plus (Cordis Corporation, Bridgewater, New Jersey) sirolimus-eluting stents (SES) with the treatment of bare-metal stents (BMS) and drug-eluting stent (DES) in-stent restenosis (ISR) in nonselected, real-world patients. There is paucity of consistent data on DES for the treatment of ISR, especially, DES ISR. The e-SELECT (Multicenter Post-Market Surveillance) registry is a Web-based, multicenter and international registry encompassing virtually all subsets of patients and lesions treated with at least 1 SES during the period from 2006 to 2008. We enrolled in this pre-specified subanalysis all patients with at least 1 clinically relevant BMS or DES ISR treated with SES. Primary endpoint was major adverse cardiac events and stent thrombosis rate at 1 year. Of 15,147 patients enrolled, 1,590 (10.5%) presented at least 1 ISR (BMS group, n = 1,235, DES group, n = 355). Patients with DES ISR had higher incidence of diabetes (39.4% vs. 26.9%, p target lesion revascularization and definite/probable late stent thrombosis were higher in patients with DES ISR (6.9% vs. 3.1%, p = 0.003, and 1.8% vs. 0.5%, p = 0.04, respectively). Use of SES for either BMS or DES ISR treatment is safe and associated with low target lesion revascularization recurrence and no apparent safety concern. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  15. Percutaneous stenting of the superior mesenteric artery for the treatment of chronic mesenteric ischemia

    International Nuclear Information System (INIS)

    Gweon, Hye Mi; Suh, Sang Hyun; Won, Jong Yun; Lee, Do Yun; Kim, Sam Soo

    2008-01-01

    We wanted to evaluate the effectiveness of stent placement on the superior mesenteric artery as a treatment for chronic mesenteric ischemia. Seven patients (mean age: 55 years, age range: 43-66 years) with chronic mesenteric ischemia were enrolled between March 2000 and September 2003. All the patients underwent pre-procedure contrast enhanced computerized tomography to evaluate for occlusion or stenosis of the mesenteric arteries and they then underwent an angiographic procedure. A balloon-expandable metal stent was placed in the superior mesenteric artery, and this was combined with balloon angioplasty and thrombolysis. We evaluated the angiographic and procedural success after the procedures. Angiographic and procedural success was obtained in 100% of the patients and the clinical symptoms improved in 100% of the patients. The patency at 6-months and 1-year was 85% and 71%, respectively. The mean follow-up period was 12 months (range: 1-25 months). During the follow-up period, ischemic symptoms recurred in 2 patients, and restenosis in a stent was confirmed with angiography; one patient was successfully treated by stent placement in the celiac artery and the other patient died due to extensive mesenteric thrombosis. For the treatment of chronic mesenteric ischemia, percutaneous stent placement on the superior mesenteric artery showed a favorable result and it was an effective alternative to surgery for the high-risk patients

  16. Percutaneous stenting of the superior mesenteric artery for the treatment of chronic mesenteric ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Gweon, Hye Mi; Suh, Sang Hyun; Won, Jong Yun [Yongdong Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Lee, Do Yun [Yonsei National College of Medicine, Seoul (Korea, Republic of); Kim, Sam Soo [Kangwon National University Hospital, Chuncheon (Korea, Republic of)

    2008-06-15

    We wanted to evaluate the effectiveness of stent placement on the superior mesenteric artery as a treatment for chronic mesenteric ischemia. Seven patients (mean age: 55 years, age range: 43-66 years) with chronic mesenteric ischemia were enrolled between March 2000 and September 2003. All the patients underwent pre-procedure contrast enhanced computerized tomography to evaluate for occlusion or stenosis of the mesenteric arteries and they then underwent an angiographic procedure. A balloon-expandable metal stent was placed in the superior mesenteric artery, and this was combined with balloon angioplasty and thrombolysis. We evaluated the angiographic and procedural success after the procedures. Angiographic and procedural success was obtained in 100% of the patients and the clinical symptoms improved in 100% of the patients. The patency at 6-months and 1-year was 85% and 71%, respectively. The mean follow-up period was 12 months (range: 1-25 months). During the follow-up period, ischemic symptoms recurred in 2 patients, and restenosis in a stent was confirmed with angiography; one patient was successfully treated by stent placement in the celiac artery and the other patient died due to extensive mesenteric thrombosis. For the treatment of chronic mesenteric ischemia, percutaneous stent placement on the superior mesenteric artery showed a favorable result and it was an effective alternative to surgery for the high-risk patients.

  17. Sex-related Impact on Clinical Outcome of Everolimus-eluting Versus Bare-metal Stents in ST-segment Myocardial Infarction. Insights From the EXAMINATION Trial.

    Science.gov (United States)

    Regueiro, Ander; Fernández-Rodríguez, Diego; Brugaletta, Salvatore; Martín-Yuste, Victoria; Masotti, Monica; Freixa, Xavier; Cequier, Ángel; Íñiguez, Andrés; Serruys, Patrick W; Sabaté, Manel

    2015-05-01

    The use of second-generation drug-eluting stents compared with bare-metal stents in patients with ST-segment elevation myocardial infarction reduces the rate of major adverse cardiac events. We aimed to evaluate the impact of sex on the performance of everolimus-eluting stents vs bare-metal stents in ST-segment elevation myocardial infarction at 2-year follow-up. This is a sub-study of the EXAMINATION trial that randomized 1498 patients with ST-segment elevation myocardial infarction undergoing percutaneous coronary intervention to everolimus-eluting or bare-metal stents. Primary end point was combined all-cause death, any recurrent myocardial infarction, and any revascularization. All end points were analyzed according to sex at 2-year follow-up. Of 1498 patients included in the trial, 254 (17.0%) were women. Women were older and had higher prevalence of hypertension and lower prevalence of smoking compared with men. In contrast with men, stent diameter was smaller in women. After multivariate analysis, the primary end point was similar between women and men (hazard ratio=0.95; 95% confidence interval, 0.66-1.37), and among women, between those treated with bare-metal vs everolimus-eluting stents (hazard ratio=2.48; 95% confidence interval, 0.95-6.46). Women showed a lower rate of repeat revascularization than men (hazard ratio=0.55; 95% confidence interval, 0.32-0.95) despite worse baseline characteristics. This difference was driven by better performance of the everolimus-eluting stent in women. Despite poorer baseline clinical characteristics, women with ST-segment elevation myocardial infarction treated with percutaneous coronary intervention showed outcomes similar to men. The use of everolimus-eluting stents may represent an added value in women as it showed a reduced rate of repeated revascularization compared to men. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  18. A precious metal alloy for construction of MR imaging-compatible balloon-expandable vascular stents

    NARCIS (Netherlands)

    L.C. van Dijk (Lukas); J. van Holten; B.P. van Dijk (Bastiaan); N.A. Matheijssen; P.M.T. Pattynama (Peter)

    2001-01-01

    textabstractThe authors developed ABI alloy, which mechanically resembles stainless steel 316. The main elements of ABI alloy are palladium and silver. Magnetic resonance (MR) images and radiographs of ABI alloy and stainless steel 316 stent models and of nitinol, tantalum, and

  19. Self-Expanding Metal Stenting for Palliation of Patients with Malignant Colonic Obstruction

    DEFF Research Database (Denmark)

    Meisner, Søren; González-Huix, Ferran; Vandervoort, Jo G

    2012-01-01

    .1%. Overall migration rate was 5.5%. Overall death rate during follow-up was 48.6% (124), with 67.7% of deaths related to the patient's colorectal cancer, unrelated in 32.3%. Only 2 deaths were related to the stent or procedure. Limitations. No control group. Conclusions. The primary palliative option...

  20. Transjugular Insertion of Bare-Metal Biliary Stent for the Treatment of Distal Malignant Obstructive Jaundice Complicated by Coagulopathy

    International Nuclear Information System (INIS)

    Tsauo Jiaywei; Li Xiao; Li Hongcui; Wei Bo; Luo Xuefeng; Zhang Chunle; Tang Chengwei; Wang Weiping

    2013-01-01

    This study was designed to investigate retrospectively the feasibility of transjugular insertion of biliary stent (TIBS) for the treatment of distal malignant obstructive jaundice complicated by coagulopathy. Between April 2005 and May 2010, six patients with distal malignant obstructive jaundice associated with coagulopathy that was unable to be corrected underwent TIBS at our institution for the palliation of jaundice. Patients’ medical record and imaging results were reviewed to obtain information about demographics, procedure details, complications, and clinical outcomes. The intrahepatic biliary tract was successfully accessed in all six patients via transjugular approach. The procedure was technically successfully in five of six patients, with a bare-metal stent implanted after traversing the biliary strictures. One procedure failed, because the guidewire could not traverse the biliary occlusion. One week after TIBS, the mean serum bilirubin in the five successful cases had decreased from 313 μmol/L (range 203.4–369.3) to 146.2 μmol/L (range 95.8–223.3) and had further decreased to 103.6 μmol/L (range 29.5–240.9) at 1 month after the procedure. No bleeding, sepsis, or other major complications were observed after the procedure. The mean survival of these five patients was 4.5 months (range 1.9–5.8). On imaging follow-up, there was no evidence of stent stenosis or migration, with 100 % primary patency. When the risks of hemorrhage from percutaneous transhepatic cholangiodrainage are high, TIBS may be an effective alternative for the treatment of distal malignant obstructive jaundice.

  1. Transjugular Insertion of Bare-Metal Biliary Stent for the Treatment of Distal Malignant Obstructive Jaundice Complicated by Coagulopathy

    Energy Technology Data Exchange (ETDEWEB)

    Tsauo Jiaywei, E-mail: 80732059@qq.com; Li Xiao, E-mail: simonlixiao@gmail.com; Li Hongcui, E-mail: lihongcui520@126.com; Wei Bo, E-mail: allyooking@tom.com; Luo Xuefeng, E-mail: luobo_913@126.com; Zhang Chunle, E-mail: sugar139000@163.com; Tang Chengwei, E-mail: 20378375@qq.com [West China Hospital of Sichuan University, Department of Gastroenterology and Hepatology (China); Wang Weiping, E-mail: irjournalclub@gmail.com [Section of Interventional Radiology, Cleveland Clinic, Imaging Institute (United States)

    2013-04-15

    This study was designed to investigate retrospectively the feasibility of transjugular insertion of biliary stent (TIBS) for the treatment of distal malignant obstructive jaundice complicated by coagulopathy. Between April 2005 and May 2010, six patients with distal malignant obstructive jaundice associated with coagulopathy that was unable to be corrected underwent TIBS at our institution for the palliation of jaundice. Patients' medical record and imaging results were reviewed to obtain information about demographics, procedure details, complications, and clinical outcomes. The intrahepatic biliary tract was successfully accessed in all six patients via transjugular approach. The procedure was technically successfully in five of six patients, with a bare-metal stent implanted after traversing the biliary strictures. One procedure failed, because the guidewire could not traverse the biliary occlusion. One week after TIBS, the mean serum bilirubin in the five successful cases had decreased from 313 {mu}mol/L (range 203.4-369.3) to 146.2 {mu}mol/L (range 95.8-223.3) and had further decreased to 103.6 {mu}mol/L (range 29.5-240.9) at 1 month after the procedure. No bleeding, sepsis, or other major complications were observed after the procedure. The mean survival of these five patients was 4.5 months (range 1.9-5.8). On imaging follow-up, there was no evidence of stent stenosis or migration, with 100 % primary patency. When the risks of hemorrhage from percutaneous transhepatic cholangiodrainage are high, TIBS may be an effective alternative for the treatment of distal malignant obstructive jaundice.

  2. Removal of Retrievable Self-Expandable Metallic Tracheobronchial Stents: An 18-Year Experience in a Single Center

    International Nuclear Information System (INIS)

    Park, Jung-Hoon; Kim, Pyeong Hwa; Shin, Ji Hoon; Tsauo, Jiaywei; Kim, Min Tae; Cho, Young Chul; Kim, Jin Hyoung; Song, Ho-Young

    2016-01-01

    PurposeThe purpose of the study was to retrospectively evaluate the technical outcomes of removal of retrievable self-expandable metallic stents (REMSs) and identify predictors of technical failure in 81 patients with benign and malignant tracheobronchial strictures.Materials and MethodsA total of 98 REMSs were removed under fluoroscopic guidance in 81 patients with benign (n = 48) or malignant (n = 33) tracheobronchial strictures. Primary and secondary technical success rates and complication rate were evaluated. Technical outcomes with regard to underlying diseases were also evaluated. Logistic regression models were constructed to identify predictors of primary technical success.ResultsPrimary and secondary technical success rates were 86.7 and 94.9 %, respectively. Stent removal-related complication rate was 7.1 % (7/98) and all were bleeding after stent removal. All bleeding complications were minor and managed conservatively. Primary technical success rate for benign strictures was significantly lower compared with that for malignant strictures (80.9 vs. 97.1 %, P = 0.029), but secondary technical success rate (93.7 vs. 97.1 %, P = 0.652) did not differ between the two groups. Granulation tissue formation was identified as an independent predictor of primary technical success (odds ratio 0.249, 95 % CI 0.071–0.874, P = 0.030).ConclusionRemoval of REMSs in patients with benign and malignant tracheobronchial strictures is safe and technically feasible. Bronchoscopic guidance may be required when the removal using a hook wire fails. The presence of granulation tissue was the negative predictor of primary technical success.

  3. Removal of Retrievable Self-Expandable Metallic Tracheobronchial Stents: An 18-Year Experience in a Single Center

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jung-Hoon; Kim, Pyeong Hwa; Shin, Ji Hoon, E-mail: jhshin@amc.seoul.kr; Tsauo, Jiaywei; Kim, Min Tae; Cho, Young Chul; Kim, Jin Hyoung; Song, Ho-Young [University of Ulsan College of Medicine, Departments of Radiology and Research Institute of Radiology, Asan Medical Center (Korea, Republic of)

    2016-11-15

    PurposeThe purpose of the study was to retrospectively evaluate the technical outcomes of removal of retrievable self-expandable metallic stents (REMSs) and identify predictors of technical failure in 81 patients with benign and malignant tracheobronchial strictures.Materials and MethodsA total of 98 REMSs were removed under fluoroscopic guidance in 81 patients with benign (n = 48) or malignant (n = 33) tracheobronchial strictures. Primary and secondary technical success rates and complication rate were evaluated. Technical outcomes with regard to underlying diseases were also evaluated. Logistic regression models were constructed to identify predictors of primary technical success.ResultsPrimary and secondary technical success rates were 86.7 and 94.9 %, respectively. Stent removal-related complication rate was 7.1 % (7/98) and all were bleeding after stent removal. All bleeding complications were minor and managed conservatively. Primary technical success rate for benign strictures was significantly lower compared with that for malignant strictures (80.9 vs. 97.1 %, P = 0.029), but secondary technical success rate (93.7 vs. 97.1 %, P = 0.652) did not differ between the two groups. Granulation tissue formation was identified as an independent predictor of primary technical success (odds ratio 0.249, 95 % CI 0.071–0.874, P = 0.030).ConclusionRemoval of REMSs in patients with benign and malignant tracheobronchial strictures is safe and technically feasible. Bronchoscopic guidance may be required when the removal using a hook wire fails. The presence of granulation tissue was the negative predictor of primary technical success.

  4. Delayed Development of Brain Abscesses Following Stent-Graft Placement in a Head and Neck Cancer Patient Presenting with Carotid Blowout Syndrome

    International Nuclear Information System (INIS)

    Oweis, Yaseen; Gemmete, Joseph J.; Chaudhary, Neeraj; Pandey, Aditya; Ansari, Sameer

    2011-01-01

    We describe the delayed development of intracranial abscesses following emergent treatment with a covered stent-graft for carotid blowout syndrome (CBS) in a patient with head and neck cancer. The patient presented with hemoptysis and frank arterial bleeding through the tracheostomy site. A self-expandable stent-graft was deployed across a small pseudoaneurysm arising from the right common carotid artery (RCCA) and resulted in immediate hemostasis. Three months later, the patient suffered a recurrent hemorrhage. CT of the neck demonstrated periluminal fluid around the caudal aspect of the stent-graft with intraluminal thrombus and a small pseudoaneurysm. Subsequently, the patient underwent a balloon test occlusion study and endovascular sacrifice of the RCCA and right internal carotid artery. MRI of the brain demonstrated at least four ring-enhancing lesions within the right cerebral hemisphere consistent with intracranial abscesses that resolved with broad-spectrum antibiotic coverage.

  5. Incidence of definite stent thrombosis or in-stent restenosis after drug-eluting stent implantation for treatment of coronary in-stent restenosis. From western denmark heart registry

    DEFF Research Database (Denmark)

    Jensen, Jesper; Jensen, Lisette Okkels; Terkelsen, Christian Juhl

    2012-01-01

    There are limited data on the optimal management of in-stent restenosis after percutaneous coronary intervention (PCI) with bare metal stent (BMS) or drug-eluting stent (DES) implantations. We assessed the clinical presentation, the incidence, and prognosis of definite stent thrombosis or resteno......There are limited data on the optimal management of in-stent restenosis after percutaneous coronary intervention (PCI) with bare metal stent (BMS) or drug-eluting stent (DES) implantations. We assessed the clinical presentation, the incidence, and prognosis of definite stent thrombosis...

  6. Newest-generation drug-eluting and bare-metal stents combined with prasugrel-based antiplatelet therapy in large coronary arteries

    DEFF Research Database (Denmark)

    Jeger, Raban; Pfisterer, Matthias; Alber, Hannes

    2012-01-01

    In the BAsel Stent Kosten Effektivitäts Trial PROspective Validation Examination (BASKET-PROVE), drug-eluting stents (DESs) had similar 2-year rates of death and myocardial infarction but lower rates of target vessel revascularization and major adverse cardiac events compared with bare-metal sten...... (BMSs). However, comparative clinical effects of newest-generation DES with biodegradable polymers vs second-generation DES or newest-generation BMS with biocompatible coatings, all combined with a prasugrel-based antiplatelet therapy, on 2-year outcomes are not known....