WorldWideScience

Sample records for metal hip resurfacing

  1. Biomimetic Composite-Metal Hip Resurfacing Implant

    Directory of Open Access Journals (Sweden)

    Habiba Bougherara

    2008-01-01

    Full Text Available Hip resurfacing technique is a conservative arthroplasty used in the young patient in which the femoral head is reshaped to accept metal cap with small guide stem. In the present investigation, a hybrid composite-metal resurfacing implant is proposed. The cup is made of carbon fiber/polyamide 12 (CF/PA12 covered with a thin layer of cobalt chrome (Co-Cr. Finite element (FE method was applied to analyze and compare the biomechanical performances of the hybrid hip resurfacing (HHR and the conventional Birmingham (BHR. Results of the finite element analysis showed that the composite implant leads to an increase in stresses in the cancellous bone by more than 15% than BHR, indicating a lower potential for stress shielding and bone fracture and higher potential for bone apposition with the HHR.

  2. Metal-on-Metal Hip Resurfacing Arthroplasty

    Science.gov (United States)

    Sehatzadeh, S; Kaulback, K; Levin, L

    2012-01-01

    Background Metal-on-metal (MOM) hip resurfacing arthroplasty (HRA) is in clinical use as an appropriate alternative to total hip arthroplasty in young patients. In this technique, a metal cap is placed on the femoral head to cover the damaged surface of the bone and a metal cup is placed in the acetabulum. Objectives The primary objective of this analysis was to compare the revision rates of MOM HRA using different implants with the benchmark set by the National Institute of Clinical Excellence (NICE). The secondary objective of this analysis was to review the literature regarding adverse biological effects associated with implant material. Review Methods A literature search was performed on February 13, 2012, to identify studies published from January 1, 2009, to February 13, 2012. Results The revision rates for MOM HRA using 6 different implants were reviewed. The revision rates for MOM HRA with 3 implants met the NICE criteria, i.e., a revision rate of 10% or less at 10 years. Two implants had short-term follow-ups and MOM HRA with one of the implants failed to meet the NICE criteria. Adverse tissue reactions resulting in failure of the implants have been reported by several studies. With a better understanding of the factors that influence the wear rate of the implants, adverse tissue reactions and subsequent implant failure can be minimized. Many authors have suggested that patient selection and surgical technique affect the wear rate and the risk of tissue reactions. The biological effects of high metal ion levels in the blood and urine of patients with MOM HRA implants are not known. Studies have shown an increase in chromosomal aberrations in patients with MOM articulations, but the clinical implications and long-term consequences of this increase are still unknown. Epidemiological studies have shown that patients with MOM HRA implants did not have an overall increase in mortality or risk of cancer. There is insufficient clinical data to confirm the

  3. 21 CFR 888.3400 - Hip joint femoral (hemi-hip) metallic resurfacing prosthesis.

    Science.gov (United States)

    2010-04-01

    ... prosthesis. 888.3400 Section 888.3400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... femoral (hemi-hip) metallic resurfacing prosthesis. (a) Identification. A hip joint femoral (hemi-hip) metallic resurfacing prosthesis is a device intended to be implanted to replace a portion of the hip joint...

  4. Inflammatory pseudotumor causing deep vein thrombosis after metal-on-metal hip resurfacing arthroplasty.

    LENUS (Irish Health Repository)

    Memon, Adeel Rasool

    2013-01-01

    Metal-on-metal hip resurfacings have recently been associated with a variety of complications resulting from adverse reaction to metal debris. We report a case of extensive soft tissue necrosis associated with a huge pelvic mass causing extensive deep vein thrombosis of the lower limb secondary to mechanical compression of the iliac vein. This is a rare and unusual cause of deep vein thrombosis after metal-on-metal hip resurfacing arthroplasty.

  5. Asymptomatic pseudotumours after metal-on-metal hip resurfacing show little change within one year

    NARCIS (Netherlands)

    van der Weegen, W.; Brakel, K.; Horn, R. J.; Hoekstra, H. J.; Sijbesma, T.; Pilot, P.; Nelissen, R. G. H. H.

    2013-01-01

    The aim of this study was to establish the natural course of unrevised asymptomatic pseudotumours after metal-on-metal (MoM) hip resurfacing during a six- to 12-month follow-up period. We used repeated metal artefact reduction sequence (MARS)-magnetic resonance imaging (MRI), serum metal ion

  6. 21 CFR 888.3410 - Hip joint metal/polymer or ceramic/polymer semiconstrained resurfacing cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... semiconstrained resurfacing cemented prosthesis. 888.3410 Section 888.3410 Food and Drugs FOOD AND DRUG... prosthesis. (a) Identification. A hip joint metal/polymer or ceramic/polymer semi-constrained resurfacing cemented prosthesis is a two-part device intended to be implanted to replace the articulating surfaces of...

  7. Metal release and metal allergy after total hip replacement with resurfacing versus conventional hybrid prosthesis

    Science.gov (United States)

    Gustafson, Klas; Jakobsen, Stig S; Lorenzen, Nina D; Thyssen, Jacob P; Johansen, Jeanne D; Bonefeld, Charlotte M; Stilling, Maiken; Baad-Hansen, Thomas; Søballe, Kjeld

    2014-01-01

    Background Metal-on-metal (MOM) total hip arthroplasties were reintroduced because of the problems with osteolysis and aseptic loosening related to polyethylene wear of early metal-on-polyethylene (MOP) arthroplasties. The volumetric wear rate has been greatly reduced with MOM arthroplasties; however, because of nano-size wear particles, the absolute number has been greatly increased. Thus, a source of metal ion exposure with the potential to sensitize patients is present. We hypothesized that higher amounts of wear particles result in increased release of metal ions and ultimately lead to an increased incidence of metal allergy. Methods 52 hips in 52 patients (median age 60 (51–64) years, 30 women) were randomized to either a MOM hip resurfacing system (ReCap) or a standard MOP total hip arthoplasty (Mallory Head/Exeter). Spot urine samples were collected preoperatively, postoperatively, after 3 months, and after 1, 2, and 5 years and tested with inductively coupled plasma-sector field mass spectrometry. After 5 years, hypersensitivity to metals was evaluated by patch testing and lymphocyte transformation assay. In addition, the patients answered a questionnaire about hypersensitivity. Results A statistically significant 10- to 20-fold increase in urinary levels of cobalt and chromium was observed throughout the entire follow-up in the MOM group. The prevalence of metal allergy was similar between groups. Interpretation While we observed significantly increased levels of metal ions in the urine during the entire follow-up period, no difference in prevalence of metal allergy was observed in the MOM group. However, the effect of long-term metal exposure remains uncertain. PMID:24930546

  8. Revision rates for metal-on-metal hip resurfacing and metal-on-metal total hip arthroplasty - a systematic review.

    Science.gov (United States)

    Ras Sørensen, Sofie-Amalie L; Jørgensen, Henrik L; Sporing, Sune L; Lauritzen, Jes B

    2016-11-10

    To compare revision rates of metal-on-metal (MoM) hip resurfacing (HRS) and MoM total hip arthroplasty (THA), as well as the primary causes for revisions. The PubMed database was queried for potentially relevant articles addressing MoMTHA and MoMHRS, a total of 51 articles were included. The review includes a total number of 5,399 MoMHRS and 3,244 THA prosthesis and the reasons for prosthesis failure were divided into 7 categories and the main causes discussed. The overall MoMTHA revision rate was 4.7% after 6.9 years. MoMHRS revision rate was 5.9% after 5.7 years. The odds ratio was 1.25 (1.03:1.53) 95% CI (p = 0.03) (MoMHRS vs. MoMTHA).The studies of hip prostheses were separated into 2 categories of short- and long-term (more or less than 5 years). Short-term revision rate for MoMTHA was 4.5% after 4.8 years, and for MoMHRS 4.0% after 4.2 years. The odds ratio was 1.09 (0.82:1.43) 95% CI (0 = 0.56) (MoMTHA vs. MoMHRS). Long-term revision rate for MoMTHA was 5.2% after 7.7 years and 8.2% after 7.6 years for MoMHRS. The odds ratio was 1.58 (1.53:1.96) 95% CI (p = 0.0001) (MoMHRS vs. MoMTHA).Revision causes were divided into 7 main categories. The most common cause for revision for both MoMTHA and MoMHRS was loosening 47.6% vs. 37.7%, fracture (MoMTHA 7.69%; MoMHRS 19.62%), metal reactions (MoMTHA 7.69%; MoMHRS 26.92%) infection (MoMTHA 12.08%; MoMHRS 6.54%), instability (MoMTHA 9.13%; MoMHRS 2.69%), manufacturer defect 6.73% for MoMTHA and nonreported for MoMHRS, and miscellaneous (MoMTHA 7.69%; MoMHRS 6.54%) was stated. The comparison of MoMHRS and MoMTHA revision rates showed no difference in the short term, however in the longer term, the revision rate of MoMHRS was significantly higher than for MoMTHA. The linear increase in revision rate of MoMHRS may indicate a progression in failure.

  9. What is the natural history of asymptomatic pseudotumours in metal-on-metal hip resurfacing patients?

    Science.gov (United States)

    Matharu, Gulraj S; Ostlere, Simon J; Pandit, Hemant G; Murray, David W

    2016-11-10

    We assessed the natural history of asymptomatic pseudotumours associated with metal-on-metal hip resurfacings (MoMHRs), and factors associated with future revision. In 2007-2008, we identified 25 MoMHRs (21 patients; mean age 59.9 years; 76% female) with asymptomatic pseudotumours. All patients underwent identical initial assessment (ultrasound, blood metal ions, radiographs, Oxford Hip Score [OHS]) and were considered asymptomatic because they denied experiencing hip symptoms, were satisfied with their MoMHR surgery, and had good or excellent OHSs (≥34). In 2012-2013, repeat assessments were performed in all non-revised patients. Revision for pseudotumour was performed/recommended in 15 MoMHRs (60%) at a mean 2.7 years (range 0.4-6.4 years) from initial assessment, with 14 developing symptoms before revision. Non-revised MoMHRs (n = 10) underwent repeat ultrasound at a mean 5.1 years (range 4.0-6.5 years) later, with no changes in pseudotumour volume (p = 0.956) or OHS (p = 0.065) between assessments. High blood cobalt (p = 0.0048) and chromium (p = 0.0162), large pseudotumours (p = 0.0458), low OHS (p = 0.0183), and bilateral MoMHRs (p = 0.049) predicted future revision. Patients with blood metal ions above established unilateral/bilateral thresholds and/or initial pseudotumours >30 cm3 had an 86.7% sensitivity, 70.0% specificity, 81.2% positive predictive value, and 77.8% negative predictive value for future revision. MoMHR patients with initially asymptomatic pseudotumours often become symptomatic and require revision. Patients with high blood metal ions and/or pseudotumours >30 cm3 should remain under annual surveillance or be considered for revision (especially in patients also having lower initial OHSs, bilateral MoMHRs, and/or those becoming symptomatic). Less regular surveillance of patients outside these parameters appears acceptable.

  10. The effect of motion patterns on edge-loading of metal-on-metal hip resurfacing.

    Science.gov (United States)

    Mellon, S J; Kwon, Y-M; Glyn-Jones, S; Murray, D W; Gill, H S

    2011-12-01

    The occurrence of pseudotumours (soft tissue masses relating to the hip joint) following metal-on-metal hip resurfacing arthroplasty (MoMHRA) has been associated with high serum metal ion levels and consequently higher than normal bearing wear. We investigated the relationship between serum metal ion levels and contact stress on the acetabular component of MoMHRA patients for two functional activities; gait and stair descent. Four subjects with MoMHRA, who had their serum metal ion levels measured, underwent motion analysis followed by CT scanning. Their motion capture data was combined with published hip contact forces and finite element models representing 14% (peak force) and 60% (end of stance) of the gait cycle and 52% (peak force) of stair descent activity were created. The inclination angle of the acetabular component was increased by 10° in 1° intervals and the contact stresses were determined at each interval for each subject. When the inclination angle was altered in such a way as to cause the hip contact force to pass through the edge of the acetabular component edge-loading occurred. Edge-loading increased the contact stress by at least 50%; the maximum increase was 108%. Patients with low serum metal ion levels showed no increase in contact stress at peak force during gait or stair descent. Patients with high serum metal ion levels exhibited edge-loading with an increase to the inclination angle of their acetabular components. The increase in inclination angle that induced edge-loading for these subjects was less than the inter-subject variability in the angle of published hip contact forces. The results of this study suggest that high serum metal ion levels are the result of inclination angle influenced edge-loading but that edge-loading cannot be attributed to inclination angle alone and that an individual's activity patterns can reduce or even override the influence of a steep acetabular component and prevent edge-loading. Copyright © 2011 IPEM

  11. Effect of simplifications of bone and components inclination on the elastohydrodynamic lubrication modeling of metal-on-metal hip resurfacing prosthesis.

    Science.gov (United States)

    Meng, Qingen; Liu, Feng; Fisher, John; Jin, Zhongmin

    2013-05-01

    It is important to study the lubrication mechanism of metal-on-metal hip resurfacing prosthesis in order to understand its overall tribological performance, thereby minimize the wear particles. Previous elastohydrodynamic lubrication studies of metal-on-metal hip resurfacing prosthesis neglected the effects of the orientations of the cup and head. Simplified pelvic and femoral bone models were also adopted for the previous studies. These simplifications may lead to unrealistic predictions. For the first time, an elastohydrodynamic lubrication model was developed and solved for a full metal-on-metal hip resurfacing arthroplasty. The effects of the orientations of components and the realistic bones on the lubrication performance of metal-on-metal hip resurfacing prosthesis were investigated by comparing the full model with simplified models. It was found that the orientation of the head played a very important role in the prediction of pressure distributions and film profiles of the metal-on-metal hip resurfacing prosthesis. The inclination of the hemispherical cup up to 45° had no appreciable effect on the lubrication performance of the metal-on-metal hip resurfacing prosthesis. Moreover, the combined effect of material properties and structures of bones was negligible. Future studies should focus on higher inclination angles, smaller coverage angle and microseparation related to the occurrences of edge loading.

  12. Revision rates for metal-on-metal hip resurfacing and metal-on-metal total hip arthroplasty – a systematic review

    DEFF Research Database (Denmark)

    Ras Sørensen, Sofie-amalie L.; Jørgensen, Henrik L.; Sporing, Sune L.

    2016-01-01

    Purpose To compare revision rates of metal-on-metal (MoM) hip resurfacing (HRS) and MoM total hip arthroplasty (THA), as well as the primary causes for revisions. Methods The PubMed database was queried for potentially relevant articles addressing MoMTHA and MoMHRS, a total of 51 articles were...... cause for revision for both MoMTHA and MoMHRS was loosening 47.6% vs. 37.7%, fracture (MoMTHA 7.69%; MoMHRS 19.62%), metal reactions (MoMTHA 7.69%; MoMHRS 26.92%) infection (MoMTHA 12.08%; MoMHRS 6.54%), instability (MoMTHA 9.13%; MoMHRS 2.69%), manufacturer defect 6.73% for MoMTHA and nonreported...

  13. Metal-on-metal hip resurfacing: correlation between clinical and radiological assessment, metal ions and ultrasound findings.

    Science.gov (United States)

    Scaglione, M; Fabbri, L; Bianchi, N; Dell'Omo, D; Guido, G

    2015-04-01

    We report the clinical, radiological and wear analysis of 52 consecutive MoM hip resurfacings (performed on 49 younger patients) to a mean follow-up of 9.2 years. Every patient underwent X-ray and clinical evaluation (HHS). Ultrasonography of the hip was performed in all patients in order to identify possible cystic or solid mass in periprosthetic tissue. In case of mass >20 mm, further MRI was performed to better analyse the characteristics of lesion. Five patients (five hips) had a revision. The overall survival rate was 90.38 %. The average HHS at follow-up examination was 95.5 points. No progressive radiolucent areas and no sclerosis or osteolysis around the implants were found. The US and RMI imaging showed a pseudotumour formation in two patients (correlated with high metal ion levels in blood and urine), both asymptomatic. A significant positive correlation between inclination of the acetabular component and serum metal ion levels was found (r = 0.64 and r = 0.62 for cobalt and chromium, respectively).

  14. Adverse reaction to metal debris in a consecutive series of DUROM™ hip resurfacing: pseudotumour incidence and metal ion concentration.

    Science.gov (United States)

    Hartmann, Albrecht; Kieback, Jan-Dirk; Lützner, Jörg; Günther, Klaus-Peter; Goronzy, Jens

    2017-07-25

    The aim of this study was to evaluate the incidence of adverse reactions to metal debris (ARMD) in a consecutive series of DUROM™ Hip Resurfacing Arthroplasty (HRA) at mid-term follow-up. Between October 2003 and March 2007 a total of 134 consecutive DUROM™ HRA in 121 patients were performed at our institution. Follow-up could be obtained in 101 unrevised patients (83%) at a mean time of 8.51 ± 0.97 years postoperatively and included patient-related outcome measurement, plain radiographs, MARS-MRI as well as whole blood metal ion assessment. 17 (16.5%) out of 103 hips revealed pseudotumour occurrence in MRI investigation, 1 (10.6%) with a diameter of ≥2 cm. Higher incidence of pseudotumours was found patients with femoral component size 7 μg/l. In contrast to cobalt determination, only elevated chromium values showed a positive association with pseudotumour occurrence and size. A significant proportion of patients developed pseudotumours and metal ion elevation in a consecutive cohort of DUROM™ HRA after mid-term follow-up. The incidence, however, seems not to differ from results of other well performing resurfacing brands; clinical relevance of our findings is unclear. Regarding potential local as well as systemic effects of metal particle release, close follow-up of patients is essential, even with clinically well-performing implants.

  15. A MRI classification of periprosthetic soft tissue masses (pseudotumours) associated with metal-on-metal resurfacing hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Hauptfleisch, Jennifer; Ostlere, Simon [Nuffield Orthopaedic Centre, Oxford University Hospitals NHS Trust, Department of Radiology, Oxford (United Kingdom); Pandit, Hemant; Grammatopoulos, George; Gill, Harinderjit S.; Murray, David W. [Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS), University of Oxford, Botnar Research Centre, Oxford (United Kingdom)

    2012-02-15

    Metal-on-metal hip resurfacing arthroplasty (MoMHRA) has become a popular option for young patients requiring hip replacement. A recognised complication is the formation of a symptomatic reactive periprosthetic soft tissue mass (pseudotumour). We present a radiological classification system for these reactive masses, dividing them into three groups: Type I are thin-walled cystic masses (cyst wall <3 mm), Type II are thick-walled cystic masses (cyst wall >3 mm, but less than the diameter of the cystic component) and Type III are predominantly solid masses. We reviewed all MRI performed over a 4-year period in patients with primary MoMHRA referred to our institution. In all cases the masses were assessed on MRI according to size, anatomical position, signal intensity and involvement of bone, muscle or neighbouring neurovascular bundles. Periprosthetic masses were seen in 33 hips in 17 female (7 bilateral) and 8 male patients (1 bilateral). The Type I lesions were the most common and more likely to be posterior to the hip joint. The Type III masses were significantly larger than the cystic lesions and were more likely to be located anterior to the hip joint. To date 22 patients have undergone revision surgery with conversions to total hip replacement. Severity of symptoms and revision rates were lowest in the Type I group and highest in the Type III group. Solid anterior pseudotumours were most likely to have the more severe symptoms and require revision surgery. (orig.)

  16. Outcomes after revision of metal on metal hip resurfacing to total arthroplasty using the direct anterior approach.

    Science.gov (United States)

    Bouveau, Victoire; Haen, Thomas-Xavier; Poupon, Joel; Nich, Christophe

    2018-03-08

    Function after revision total hip arthroplasty (THA) in failed metal-on-metal (MoM) hip resurfacing arthroplasty (HRA) is variable, but post-operative complication rates are reportedly high. We hypothesized HRA conversion to THA using the direct anterior approach (DAA) would be associated with optimal outcome. Seventeen MoM-HRAs in 15 patients (seven males, eight females) were revised through the DAA. The mean age was 45 years (28-59 yrs). The most common indications for revision were aseptic loosening of the acetabular component or of the femoral component and femoral neck fracture. In 16 hips, a conversion to a ceramic-on-ceramic (CoC) (13 hips) or to a metal-on polyethylene (MOP) (2), or to a large-head MoM (1) THA was done. An isolated femoral revision was done in one hip. After 6.7 ± 3 years, no hip had required a re-revision. The Postel-Merle d'Aubigne (PMA) functional score improved from 9 (4-14) to 16 (12-18) (p hip) and dysesthesia of the lateral femoral cutaneous nerve (four hips) were reported. Mean serum chromium concentration decreased from 33.2 μg/L (11.8-62 μg/L) pre-operatively to 5.8 μg/L (0.4-35.5 μg/L) post-operatively (p Revision of failed MoM-HRA using the DAA resulted in an acceptable clinical outcome, no specific complication and no further surgery. A consistent decline in serum ion levels may be expected following HRA conversion to THA.

  17. Hip Resurfacing: An Alternative to Conventional Hip Replacement?

    Science.gov (United States)

    ... Is hip resurfacing a good alternative to hip replacement? Answers from Mark Spangehl, M.D. Hip resurfacing has lost favor with many surgeons ... women with poor bone quality. Unlike traditional hip replacement, hip resurfacing doesn't completely replace the "ball" ...

  18. Usefulness of metal artifact reduction with WARP technique at 1.5 and 3T MRI in imaging metal-on-metal hip resurfacings

    Energy Technology Data Exchange (ETDEWEB)

    Lazik, Andrea; Lauenstein, Thomas C.; Theysohn, Jens M. [University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Landgraeber, Stefan; Schulte, Patrick [University Hospital Essen, Department of Orthopedics, Essen (Germany); Kraff, Oliver [University of Duisburg-Essen, Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany)

    2015-03-25

    To evaluate the usefulness of the metal artifact reduction technique ''WARP'' in the assessment of metal-on-metal hip resurfacings at 1.5 and 3T in the context of image quality and imaging speed. Nineteen patients (25 hip resurfacings) were randomized for 1.5 and 3T MRI, both including T1 and T2 turbo spin-echo as well as turbo inversion recovery magnitude sequences with and without view angle tilting and high bandwidth. Additional 3T sequences were acquired with a reduced number of averages and using the parallel acquisition technique for accelerating imaging speed. Artifact size (diameter, area), image quality (5-point scale) and delineation of anatomical structures were compared among the techniques, sequences and field strengths using the Wilcoxon sign-rank and paired t-test with Bonferroni correction. At both field strengths, WARP showed significant superiority over standard sequences regarding image quality, artifact size and delineation of anatomical structures. At 3T, artifacts were larger compared to 1.5T without affecting diagnostic quality, and scanning time could be reduced by up to 64 % without quality degradation. WARP proved useful in imaging metal-on-metal hip resurfacings at 1.5T as well as 3T with better image quality surrounding the implants. At 3T imaging could be considerably accelerated without losing diagnostic quality. (orig.)

  19. Usefulness of metal artifact reduction with WARP technique at 1.5 and 3T MRI in imaging metal-on-metal hip resurfacings

    International Nuclear Information System (INIS)

    Lazik, Andrea; Lauenstein, Thomas C.; Theysohn, Jens M.; Landgraeber, Stefan; Schulte, Patrick; Kraff, Oliver

    2015-01-01

    To evaluate the usefulness of the metal artifact reduction technique ''WARP'' in the assessment of metal-on-metal hip resurfacings at 1.5 and 3T in the context of image quality and imaging speed. Nineteen patients (25 hip resurfacings) were randomized for 1.5 and 3T MRI, both including T1 and T2 turbo spin-echo as well as turbo inversion recovery magnitude sequences with and without view angle tilting and high bandwidth. Additional 3T sequences were acquired with a reduced number of averages and using the parallel acquisition technique for accelerating imaging speed. Artifact size (diameter, area), image quality (5-point scale) and delineation of anatomical structures were compared among the techniques, sequences and field strengths using the Wilcoxon sign-rank and paired t-test with Bonferroni correction. At both field strengths, WARP showed significant superiority over standard sequences regarding image quality, artifact size and delineation of anatomical structures. At 3T, artifacts were larger compared to 1.5T without affecting diagnostic quality, and scanning time could be reduced by up to 64 % without quality degradation. WARP proved useful in imaging metal-on-metal hip resurfacings at 1.5T as well as 3T with better image quality surrounding the implants. At 3T imaging could be considerably accelerated without losing diagnostic quality. (orig.)

  20. Metal release and metal allergy after total hip replacement with resurfacing versus conventional hybrid prosthesis 5-year follow-up of 52 patients

    DEFF Research Database (Denmark)

    Gustafson, Klas; Jakobsen, Stig S; Lorenzen, Nina D

    2014-01-01

    to an increased incidence of metal allergy. METHODS: 52 hips in 52 patients (median age 60 (51-64) years, 30 women) were randomized to either a MOM hip resurfacing system (ReCap) or a standard MOP total hip arthoplasty (Mallory Head/Exeter). Spot urine samples were collected preoperatively, postoperatively, after....... RESULTS: A statistically significant 10- to 20-fold increase in urinary levels of cobalt and chromium was observed throughout the entire follow-up in the MOM group. The prevalence of metal allergy was similar between groups. INTERPRETATION: While we observed significantly increased levels of metal ions...

  1. Advanced metal artifact reduction MRI of metal-on-metal hip resurfacing arthroplasty implants: compressed sensing acceleration enables the time-neutral use of SEMAC

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, Jan; Thawait, Gaurav K. [Johns Hopkins University School of Medicine, Russell H. Morgan Department of Radiology and Radiological Science, Section of Musculoskeletal Radiology, Baltimore, MD (United States); Fritz, Benjamin [University of Freiburg, Department of Radiology, Freiburg im Breisgau (Germany); Raithel, Esther; Nittka, Mathias [Siemens Healthcare GmbH, Erlangen (Germany); Gilson, Wesley D. [Siemens Healthcare USA, Inc., Baltimore, MD (United States); Mont, Michael A. [Cleveland Clinic Foundation, Department of Orthopedic Surgery, Cleveland, OH (United States)

    2016-10-15

    Compressed sensing (CS) acceleration has been theorized for slice encoding for metal artifact correction (SEMAC), but has not been shown to be feasible. Therefore, we tested the hypothesis that CS-SEMAC is feasible for MRI of metal-on-metal hip resurfacing implants. Following prospective institutional review board approval, 22 subjects with metal-on-metal hip resurfacing implants underwent 1.5 T MRI. We compared CS-SEMAC prototype, high-bandwidth TSE, and SEMAC sequences with acquisition times of 4-5, 4-5 and 10-12 min, respectively. Outcome measures included bone-implant interfaces, image quality, periprosthetic structures, artifact size, and signal- and contrast-to-noise ratios (SNR and CNR). Using Friedman, repeated measures analysis of variances, and Cohen's weighted kappa tests, Bonferroni-corrected p-values of 0.005 and less were considered statistically significant. There was no statistical difference of outcomes measures of SEMAC and CS-SEMAC images. Visibility of implant-bone interfaces and pseudocapsule as well as fat suppression and metal reduction were ''adequate'' to ''good'' on CS-SEMAC and ''non-diagnostic'' to ''adequate'' on high-BW TSE (p < 0.001, respectively). SEMAC and CS-SEMAC showed mild blur and ripple artifacts. The metal artifact size was 63 % larger for high-BW TSE as compared to SEMAC and CS-SEMAC (p < 0.0001, respectively). CNRs were sufficiently high and statistically similar, with the exception of CNR of fluid and muscle and CNR of fluid and tendon, which were higher on intermediate-weighted high-BW TSE (p < 0.005, respectively). Compressed sensing acceleration enables the time-neutral use of SEMAC for MRI of metal-on-metal hip resurfacing implants when compared to high-BW TSE and image quality similar to conventional SEMAC. (orig.)

  2. Hip resurfacing: history, current status, and future.

    Science.gov (United States)

    Amstutz, Harlan C; Le Duff, Michel J

    2015-01-01

    Hip resurfacing arthroplasty (HRA) presents several advantages over conventional total hip arthroplasty (THA), including conservation and preservation of bone, reduced risk of dislocation, easy replication of hip biomechanics and easy revision if needed. It is a particularly appealing procedure for young patients. HRA has been performed for over 40 years following the same technological advances as THA. The bearing material used by most designs is metal-on-metal (MoM), which has the best compromise between strength and wear properties. However, MoM HRA has a specific set of possible complications. Aseptic femoral failures were initially the most prevalent cause for revision but progress in patient selection and surgical technique seem to have resolved this problem. Wear-related failures (high metal ion levels and adverse local tissue reactions) are now the main concern, and are essentially associated with poor acetabular component design and orientation, to which MoM is more sensitive than other bearing materials. The concept of functional coverage is key to understanding how MoM bearings are affected by edge wear. Only a 3-D assessment of cup position (e.g., the contact patch to rim distance) provides the necessary information to determine the role of cup positioning in relationship with abnormal bearing wear.The concept of hip resurfacing is more valid today than ever as the age of the patients in need of hip arthroplasty keeps getting lower. The recent publication of several excellent long-term survivorship results suggests that selection of a well-designed resurfacing system and accuracy in the placement of the cup can achieve long-term durability.

  3. Dislocation and spontaneous reduction of the femoral implant against the femoral neck in an infected metal on metal hip resurfacing with complex collection

    Energy Technology Data Exchange (ETDEWEB)

    Tins, Bernhard, E-mail: Bernhard.Tins@rjah.nhs.uk [Department of Radiology, RJAH Orthopaedic Hospital, Oswestry, Shropshire, SY 107 AG (United Kingdom)

    2011-07-15

    Metal on metal resurfacing hip implants are known to have complications unique to this type of implant. The case presented adds a further previously not described complication, the dislocation and spontaneous reduction of the pin of the femoral component against the femoral neck. The radiographic and CT findings are demonstrated. The dislocation was aided by bone loss due to an infection with a large periarticular collection. Periarticular collections in hip resurfacings are often due to a hypersensitivity type reaction to metal debris. However in the case presented it was due to infection. MRI was not able to discern the infection from a sterile collection. CT demonstrated bone loss and periosteal reaction suggestive of infection. In addition calcification of the pseudocapsule was seen, this is not a recognized feature of sterile collections.

  4. Hip resurfacing arthroplasty and perioperative blood testing.

    Science.gov (United States)

    Cook, Andrew; Cook, Steven; Smith, Ian; Weinrauch, Patrick

    2014-01-01

    It is standard practice in many institutions to routinely perform preoperative and postoperative haemoglobin level testing in association with hip joint arthroplasty procedures. It is our observation, however, that blood transfusion after uncomplicated primary hip arthroplasty in healthy patients is uncommon and that the decision to proceed with blood transfusion is typically made on clinical grounds. We therefore question the necessity and clinical value of routine perioperative blood testing about the time of hip resurfacing arthroplasty. We present analysis of perioperative blood tests and transfusion rates in 107 patients undertaking unilateral hybrid hip resurfacing arthroplasty by the senior author at a single institution over a three-year period. We conclude that routine perioperative testing of haemoglobin levels for hip resurfacing arthroplasty procedures does not assist in clinical management. We recommend that postoperative blood testing only be considered should the patient demonstrate clinical signs of symptomatic anaemia or if particular clinical circumstances necessitate.

  5. Hip Resurfacing Arthroplasty and Perioperative Blood Testing

    Directory of Open Access Journals (Sweden)

    Andrew Cook

    2014-01-01

    Full Text Available It is standard practice in many institutions to routinely perform preoperative and postoperative haemoglobin level testing in association with hip joint arthroplasty procedures. It is our observation, however, that blood transfusion after uncomplicated primary hip arthroplasty in healthy patients is uncommon and that the decision to proceed with blood transfusion is typically made on clinical grounds. We therefore question the necessity and clinical value of routine perioperative blood testing about the time of hip resurfacing arthroplasty. We present analysis of perioperative blood tests and transfusion rates in 107 patients undertaking unilateral hybrid hip resurfacing arthroplasty by the senior author at a single institution over a three-year period. We conclude that routine perioperative testing of haemoglobin levels for hip resurfacing arthroplasty procedures does not assist in clinical management. We recommend that postoperative blood testing only be considered should the patient demonstrate clinical signs of symptomatic anaemia or if particular clinical circumstances necessitate.

  6. Effects of chronic cobalt and chromium exposure after metal-on-metal hip resurfacing: An epigenome-wide association pilot study.

    Science.gov (United States)

    Steinberg, Julia; Shah, Karan M; Gartland, Alison; Zeggini, Eleftheria; Wilkinson, Jeremy Mark

    2017-10-01

    Metal-on-metal (MOM) hip resurfacing has recently been a popular prosthesis choice for the treatment of symptomatic arthritis, but results in the release of cobalt and chromium ions into the circulation that can be associated with adverse clinical effects. The mechanism underlying these effects remains unclear. While chromosomal aneuploidy and translocations are associated with this exposure, the presence of subtle structural epigenetic modifications in patients with MOM joint replacements remains unexplored. Consequently, we analyzed whole blood DNA methylation in 34 OA patients with MOM hip resurfacing (MOM HR) compared to 34 OA patients with non-MOM total hip replacements (non-MOM THR), using the genome-wide Illumina HumanMethylation 450k BeadChip. No probes showed differential methylation significant at 5% false-discovery rate (FDR). We also tested association of probe methylation levels with blood chromium and cobalt levels directly; there were no significant associations at 5% FDR. Finally, we used the "epigenetic clock" to compare estimated to actual age at sample for all individuals. We found no significant difference between MOM HR and non-MOM THR, and no correlation of age acceleration with blood metal levels. Our results suggest the absence of large methylation differences systemically following metal exposure, however, larger sample sizes will be required to identify potential small effects. Any DNA methylation changes that may occur in the local periprosthetic tissues remain to be elucidated. © 2017 The Authors. Orthopaedic Research Society. Published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. J Orthop Res 35:2323-2328, 2017. © 2017 The Authors. Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  7. A Randomized Seven-Year Study on Performance of the Stemmed Metal M2a-Magnum and Ceramic C2a-Taper, and the Resurfacing ReCap Hip Implants

    DEFF Research Database (Denmark)

    Borgwardt, Arne; Borgwardt, Lotte; Zerahn, Bo

    2018-01-01

    BACKGROUND: The large-diameter metal-on-metal hip prostheses were expected to have low wear and reduced dislocation rate compared to the traditional metal-on-polyethylene implants. We compare 2 such prostheses, the ReCap resurfacing implant and the M2a-Magnum stemmed implant, with the C2a ceramic...

  8. The Effectiveness of Blood Metal Ions in Identifying Patients with Unilateral Birmingham Hip Resurfacing and Corail-Pinnacle Metal-on-Metal Hip Implants at Risk of Adverse Reactions to Metal Debris.

    Science.gov (United States)

    Matharu, Gulraj S; Berryman, Fiona; Brash, Lesley; Pynsent, Paul B; Treacy, Ronan B C; Dunlop, David J

    2016-04-20

    We investigated whether blood metal ions could effectively identify patients with metal-on-metal hip implants with two common designs (Birmingham Hip Resurfacing [BHR] and Corail-Pinnacle) who were at risk of adverse reactions to metal debris. This single-center, prospective study involved 598 patients with unilateral hip implants (309 patients with the BHR implant and 289 patients with the Corail-Pinnacle implant) undergoing whole blood metal ion sampling at a mean time of 6.9 years. Patients were classified into two groups, one that had adverse reactions to metal debris (those who had to undergo revision for adverse reactions to metal debris or those with adverse reactions to metal debris on imaging; n = 46) and one that did not (n = 552). Three metal ion parameters (cobalt, chromium, and cobalt-chromium ratio) were compared between groups. Optimal metal ion thresholds for identifying patients with adverse reactions to metal debris were determined using receiver operating characteristic analysis. All ion parameters were significantly higher (p adverse reactions to metal debris compared with those who did not. Cobalt maximized the area under the curve for patients with the BHR implant (90.5%) and those with the Corail-Pinnacle implant (79.6%). For patients with the BHR implant, the area under the curve for cobalt was significantly greater than that for the cobalt-chromium ratio (p = 0.0005), but it was not significantly greater than that for chromium (p = 0.8483). For the patients with the Corail-Pinnacle implant, the area under the curve for cobalt was significantly greater than that for chromium (p = 0.0004), but it was similar to that for the cobalt-chromium ratio (p = 0.8139). Optimal blood metal ion thresholds for identifying adverse reactions to metal debris varied between the two different implants. When using cobalt, the optimal threshold for identifying adverse reactions to metal debris was 2.15 μg/L for the BHR group and 3.57 μg/L for the Corail

  9. Hip resurfacing does not improve proprioception compared with THA.

    Science.gov (United States)

    Larkin, Brian; Nyazee, Humaa; Motley, John; Nunley, Ryan M; Clohisy, John C; Barrack, Robert L

    2014-02-01

    Proposed benefits of total hip resurfacing arthroplasty over total hip arthroplasty (THA) include better proprioception, but this has not been rigorously tested or validated. Our purpose was to apply an advanced testing device that objectively quantifies dynamic postural stability to determine if total hip resurfacing is associated with improved proprioception compared with standard or large-head THA. Three groups of 25 patients (total hip resurfacing, THA femoral head > 32 mm, THA femoral head ≤ 32 mm) and a matched control group were recruited. All participants had UCLA scores ≥ 5 and Harris hip scores ≥ 90 at the time of testing. Testing was conducted using a commercially available device that uses a multidirectional, powered platform to measure deviations of the center of mass and consisted of trials with both double- and single-limb support. Double-limb testing showed no differences between groups. In single-limb testing, the operative side performed better in patients who had undergone total hip resurfacing versus THA, but this difference disappeared when the operative side was normalized to the nonoperative side. When compared with control subjects who had not had arthroplasty, both operative and nonoperative sides showed significantly worse proprioception for all arthroplasty cohorts, suggesting that decreased proprioception is associated with arthritis of the hip in young adults. Total hip resurfacing arthroplasty did not result in improved proprioception compared with THA. These results tend to refute the concept that improved proprioception is a rationale for selecting total hip resurfacing over THA in young patients.

  10. Patient-reported outcome of hip resurfacing arthroplasty and standard total hip replacement after short-term follow-up

    DEFF Research Database (Denmark)

    Nissen, Nina; Douw, Karla; Overgaard, Søren

    2011-01-01

    The purpose of this study was to investigate patientreported outcome in terms of satisfaction in two study groups that had undergone hip resurfacing arthro-plasty (HRA) or total hip replacement (THR). The procedure consists of placing a hollow, mushroom-shaped metal cap over the femoral head while...

  11. Femoral component loosening after hip resurfacing arthroplasty

    International Nuclear Information System (INIS)

    Zustin, Jozef; Sauter, Guido; Hahn, Michael; Morlock, Michael M.; Ruether, Wolfgang; Amling, Michael

    2010-01-01

    Before the re-introduction of the current generation of total hip resurfacing arthroplasty, component loosening and osteolysis were of great concern to the orthopaedic community. Early, mid- and long-term clinical results are encouraging, but component loosening still exists. Macroscopic, contact radiographic and histopathological analyses after undecalcified preparation of bone tissue specimens were performed. To investigate the frequency and morphological patterns of the loosening of the femoral component, we analysed a series of 190 retrieved femoral remnants that were revised for aseptic failures. Thirty-five (18.4%) hips were revised for clinical and/or radiographic loosening of the femoral component. Pseudoarthrosis (n = 17; median in situ time: 16 weeks, interquartile range [IQR]: 9 to 34), collapsed osteonecrosis (n = 5; median in situ time: 79 weeks, IQR: 63 to 97), cement-socket debonding (n = 3; median in situ time: 89 weeks, IQR: 54 to 97) and at later follow-up bone-cement loosening (n = 10; median in situ time: 175 weeks; IQR 112 to 198; p =0.005) were distinct patterns of the femoral remnant-implant loosening. Fibrocartilaginous metaplasia of interface bone trabeculae (n = 38; median in situ time: 61 weeks, IQR: 32 to 138) was strongly associated with femoral component loosening (p = 0.009). Both the trabecular hyperosteoidosis (n = 32; median in situ time: 71 weeks, IQR 50 to 129) and excessive intraosseous lymphocyte infiltration (n = 12; median in situ time: 75 weeks, IQR 51 to 98) at the bone-cement interface correlated strongly with fibrocartilaginous metaplasia (p = 0.001 and p = 0.016 respectively) and all three lesions were associated with the female gender (p = 0.021, p = 0.009, and p = 0.051). Femoral component loosening at early follow-up was mostly caused by pathological changes of the femoral remnant bone tissue: pseudoarthrosis and collapsed osteonecrosis. Fibrocartilaginous metaplasia was frequently observed in hips with femoral

  12. High-impact sport after hip resurfacing: The Ironman triathlon.

    Science.gov (United States)

    Girard, J; Lons, A; Pommepuy, T; Isida, R; Benad, K; Putman, S

    2017-09-01

    Returning to high-impact sport is an increasingly frequent functional demand following hip replacement. The literature, however, is sparse on the subject and nonexistent regarding triathlon. We therefore conducted a retrospective study of hip resurfacing in triathlon players, to determine: (1) whether it is possible to return to this kind of sport; (2) if so, whether it is possible to return to the same level; and (3) how a resurfaced hip behaves under these conditions. Hip resurfacing allows return to competition level in long-distance triathlon. A single-center single-operator retrospective study included patients undergoing hip resurfacing with the Conserve Plus implant inserted through a posterolateral approach, who had ceased long-distance triathlon practice due to osteoarthritis of the hip. Fifty-one of the 1688 patients undergoing resurfacing during the inclusion period were long-distance triathlon players. The series comprised 48 patients: 51 implants; 43 male, 5 female; mean age, 44.8 years (range, 28.2-58.9 years). At a mean 4.7 years' follow-up (range, 2.2-7.6 years), all clinical scores showed significant improvement; Merle d'Aubigné and Harris scores rose respectively from 12.3 (5-16) and 42 (37-56) preoperatively to 17.5 (13-18) and 93.2 (73-100) (Phip resurfacing. Non-impact sports (swimming, cycling) predominated postoperatively, whereas the rate of impact sport (running) diminished. Return to competition-level sport (extreme triathlon) was possible for 28/48 patients (58%). Implant survival seemed unaffected by this high-impact sports activity at a mean 4.7 years' follow-up. IV, retrospective, non-controlled. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  13. Comparison of acetabular reamings during hip resurfacing versus uncemented total hip arthroplasty.

    LENUS (Irish Health Repository)

    Brennan, S A

    2009-04-01

    PURPOSE: To compare the quantity of bone removed from the acetabulum during resurfacing hip arthroplasty versus uncemented total hip arthroplasty (THA). METHODS: 62 consecutive patients with osteoarthritis of the hip were prospectively studied. 24 men and 7 women aged 40 to 86 (mean, 59) years underwent Birmingham hip resurfacing. 13 men and 18 women aged 34 to 88 (mean, 61) years underwent uncemented THA using the trident acetabular cup. Obese elderly women at risk of femoral neck fracture and patients with large subchondral pseudocysts or a history of avascular necrosis of the femoral head were assigned to uncemented THA. Acetabular reamings were collected; marginal osteophytes were not included. The reamings were dehydrated, defatted, and weighed. RESULTS: The mean weight of acetabular reamings was not significantly different between patients undergoing hip resurfacing and uncemented THA (p=0.57). CONCLUSION: In hip resurfacing, the use of an appropriately small femoral component avoids oversizing the acetabular component and removal of excessive bone stock.

  14. Survivorship and clinical outcome of Birmingham hip resurfacing: a minimum ten years' follow-up.

    Science.gov (United States)

    Azam, Md Quamar; McMahon, Stephen; Hawdon, Gabrielle; Sankineani, Sukesh Rao

    2016-01-01

    Resurfacing as a percentage of total hip arthroplasty rose from 5.6 % in 2001 to 8.9 % in 2005 in Australia. During the same period the resurfacing to conventional prosthesis rose from 19.6 % to 29 % in the younger age group (less than 55 years). Long term (more than ten years) functional results of BHR are sparingly documented. Among the literatures available, the patient selection criteria vary from osteoarthritis, avascular necrosis, and dysplastic hip to slipped capital femoral epiphysis. The objective of the current study is to evaluate long term survivorship and functional outcome of Birmingham hip resurfacing surgery in osteoarthritic hip patients performed by a single surgeon. In this retrospective clinical study, all patients who underwent hip resurfacing for osteoarthritis of hip between 1999 and 2004 are included. All surgeries were performed by single surgeon (SJM) and in all patients Smith & Nephew system (Midland Medical Technologies, Birmingham, United Kingdom)) was used. Revision surgery is considered the end point of survivorship. Means, standard deviations, and confidence interval were calculated for all continuous measures. Survival analysis was performed with the Kaplan-Meier method and 95 % confidence intervals were calculated. The result is based on 222 patients (244 hips). This included 153 males and 69 females. Our mean follow up was 12.05 years and overall survival was 93.7 %. In terms of gender, survival in males was 95.43 % while in females it was 89.86 %. Failure was seen in 14 patients (16 hips), which included seven female (10.14 %) and seven male (4.57 %) patients. Failure of femoral components due to aseptic loosening and varus collapse was seen in eight patients after a mean 9.6 years. Metal allergy was seen in three patients (five hips), all of them were female of which two had bilateral resurfacing. Other complications included femoral neck stress fractures in two patients and acetabular component loosening in one patient. We

  15. The Tribology of Explanted Hip Resurfacings Following Early Fracture of the Femur

    Directory of Open Access Journals (Sweden)

    James K. Lord

    2015-10-01

    Full Text Available A recognized issue related to metal-on-metal hip resurfacings is early fracture of the femur. Most theories regarding the cause of fracture relate to clinical factors but an engineering analysis of failed hip resurfacings has not previously been reported. The objective of this work was to determine the wear volumes and surface roughness values of a cohort of retrieved hip resurfacings which were removed due to early femoral fracture, infection and avascular necrosis (AVN. Nine resurfacing femoral heads were obtained following early fracture of the femur, a further five were retrieved due to infection and AVN. All fourteen were measured for volumetric wear using a co-ordinate measuring machine. Wear rates were then calculated and regions of the articulating surface were divided into “worn” and “unworn”. Roughness values in these regions were measured using a non-contacting profilometer. The mean time to fracture was 3.7 months compared with 44.4 months for retrieval due to infection and AVN. Average wear rates in the early fracture heads were 64 times greater than those in the infection and AVN retrievals. Given the high wear rates of the early fracture components, such wear may be linked to an increased risk of femoral neck fracture.

  16. Resurfacing total hip replacement–a therapeutical approach in postmenopausal women with osteoporosis and hip arthrosis

    OpenAIRE

    Popescu, D; Ene, R; Cirstoiu, C

    2011-01-01

    Aim: Patients with incipient hip arthrosis may benefit from a relatively new therapeutical approach using resurfacing total hip replacement, but in those with associated osteoporosis, this type of surgical intervention is contraindicated, given the poor quality of osteoporotic bones. We assessed the efficacy of the antiosteoporotic pharmacological therapy to improve bone quality and bone strength in postmenopausal women diagnosed with hip arthrosis and osteoporosis thus facilitating the hip s...

  17. Hip Resurfacing Arthroplasty and Perioperative Blood Testing

    OpenAIRE

    Cook, Andrew; Cook, Steven; Smith, Ian; Weinrauch, Patrick

    2014-01-01

    It is standard practice in many institutions to routinely perform preoperative and postoperative haemoglobin level testing in association with hip joint arthroplasty procedures. It is our observation, however, that blood transfusion after uncomplicated primary hip arthroplasty in healthy patients is uncommon and that the decision to proceed with blood transfusion is typically made on clinical grounds. We therefore question the necessity and clinical value of routine perioperative blood testin...

  18. Confronting hip resurfacing and big femoral head replacement gait analysis

    Directory of Open Access Journals (Sweden)

    Panagiotis K. Karampinas

    2014-03-01

    Full Text Available Improved hip kinematics and bone preservation have been reported after resurfacing total hip replacement (THRS. On the other hand, hip kinematics with standard total hip replacement (THR is optimized with large diameter femoral heads (BFH-THR. The purpose of this study is to evaluate the functional outcomes of THRS and BFH-THR and correlate these results to bone preservation or the large femoral heads. Thirty-one patients were included in the study. Gait speed, postural balance, proprioception and overall performance. Our results demonstrated a non-statistically significant improvement in gait, postural balance and proprioception in the THRS confronting to BFH-THR group. THRS provide identical outcomes to traditional BFH-THR. The THRS choice as bone preserving procedure in younger patients is still to be evaluated.

  19. Finite element modeling of resurfacing hip prosthesis: estimation of accuracy through experimental validation.

    Science.gov (United States)

    Taddei, Fulvia; Martelli, Saulo; Gill, Harinderjit Singh; Cristofolini, Luca; Viceconti, Marco

    2010-02-01

    Metal-on-metal hip resurfacing is becoming increasingly popular, and a number of new devices have been recently introduced that, in the short term, appear to have satisfactory outcome but many questions are still open on the biomechanics of the resurfaced femur. This could be investigated by means of finite element analysis, but, in order to be effective in discerning potential critical conditions, the accuracy of the models' predictions should be assessed. The major goal of this study was to validate, through a combined experimental-numerical study, a finite element modeling procedure for the simulation of resurfaced femurs. In addition, a preliminary biomechanical analysis of the changes induced in the femoral neck biomechanics by the presence of the device was performed, under a physiologic range of hip joint reaction directions. For this purpose, in vitro tests and a finite element model based on the same specimen were developed using a cadaver femur. The study focused on the Conserve Plus, one of the most common contemporary resurfacing designs. Five loading configurations were identified to correspond to the extremes of physiological directions for the hip joint. The agreement between experimental measurements and numerical predictions was good both in the prediction of the femoral strains (R(2)>0.9), and in the prosthesis micromotions (errorprosthesis, apart from localized strain increments that can be considerable, always predicted near the stem. Low micromotions and contact pressure were predicted, suggesting a good stability of the prosthesis. The model accuracy was good in the prediction of the femoral strains and moderately good in the prediction of the bone-prosthesis micromovements. Although the investigated loading conditions were not completely physiological, the preliminary biomechanical analysis showed relatively small changes for the proximal femur after implantation. This validated model can support realistic simulations to examine physiological

  20. A Randomized Seven-Year Study on Performance of the Stemmed Metal M2a-Magnum and Ceramic C2a-Taper, and the Resurfacing ReCap Hip Implants.

    Science.gov (United States)

    Borgwardt, Arne; Borgwardt, Lotte; Zerahn, Bo; Daugaard, Henrik; Borgwardt, Lise; Ribel-Madsen, Søren

    2017-12-05

    The large-diameter metal-on-metal hip prostheses were expected to have low wear and reduced dislocation rate compared to the traditional metal-on-polyethylene implants. We compare 2 such prostheses, the ReCap resurfacing implant and the M2a-Magnum stemmed implant, with the C2a ceramic-on-ceramic stemmed implant as to clinical performance, serum concentrations of prosthesis metals, and the durability of the implants in a randomized, controlled clinical trial at 7 years of follow-up. All included patients had osteoarthritis. Preoperatively, the size of the implants was estimated from a magnetic resonance imaging (MRI) scan. Follow-up data included serum cobalt and chromium concentrations, Oxford and Harris Hip Scores, leg press and abduction force, 6-minute walk distance, WOMAC and SF-36 self-assessment scores, and from the 7th postoperative year also ultrasonography (US) examination of the soft tissue adjacent to the implant as well as MRI with metal artifact reduction sequence (MARS-MRI) when indicated. One hundred fifty-two hips in 146 patients were included. The serum cobalt and chromium concentrations were significantly higher for the 2 metal-on-metal prostheses than for the ceramic-on-ceramic, with the M2a-Magnum as the highest. No significant difference was found between the groups concerning physical performance measurements and scores as well as dislocations and prosthesis survival. Five revisions were done and concerned all groups, for reasons of pain, high serum cobalt and chromium concentrations, cystic fluid collection around the joint, and infection. Metal concentrations, US, and MARS-MRI contributed to the decision making regarding prosthesis revision. Metal concentrations were significantly higher for the metal-on-metal prostheses than for the ceramic-on-ceramic. The clinical performance was good in all 3 prosthesis groups. Metal concentrations, US, and MARS-MRI findings were of use to identify hips needing revision. ID Number in Clinical

  1. Comparison of Cemented and Bone Ingrowth Fixation Methods in Hip Resurfacing for Osteonecrosis.

    Science.gov (United States)

    O'Leary, Ryan J; Gaillard, Melissa D; Gross, Thomas P

    2017-02-01

    The optimal surgical treatment for osteonecrosis of the femoral head has yet to be elucidated. To evaluate the role of femoral fixation techniques in hip resurfacing, we present a comparison of the results for 2 consecutive groups: group 1 (75 hips) received hybrid hip resurfacing implants with a cemented femoral component; group 2 (103 hips) received uncemented femoral components. Both groups received uncemented acetabular components. We retrospectively analyzed our clinical database to compare failures, reoperations, complications, clinical results, metal ion test results, and X-ray measurements. Using consecutive groups caused time interval bias, so we required all group 2 patients to be at least 2 years out from surgery; we compared results from 2 years and final follow-up. Patient groups matched similarly in age, body mass index, and percent female. Despite similar demographics, the uncemented, group 2 cases showed a lower raw failure rate (0% vs 16%; P < .0001), a lower 2-year failure rate (0% vs 7%; P = .04), and a superior 8-year implant survivorship (100% vs 91%; log-rank P = .0028; Wilcoxon P = .0026). In cases that did not fail, patient clinical (P = .05), activity (P = .02), and pain scores (P = .03), as well as acetabular component position (P < .0001), all improved in group 2, suggesting advancements in surgical management. There were no cases of adverse wear-related failure in either group. This study demonstrates a superior outcome for cases of osteonecrosis with uncemented hip resurfacings compared to cases employing hybrid devices. Copyright © 2016 The Author(s). Published by Elsevier Inc. All rights reserved.

  2. What are the risks accompanying the reduced wear benefit of low-clearance hip resurfacing?

    Science.gov (United States)

    Daniel, Joseph; Ziaee, Hena; Kamali, Amir; Pradhan, Chandra; McMinn, Derek

    2012-10-01

    Clearance is an important determinant of metal-metal bearing function. Tribologic theory and laboratory evidence suggest low clearance (LC) reduces wear but with a potential to increase friction and clinical reports show LC resurfacings have high implant failure rates. Thus, the role of LC is unclear. We asked: is in vivo wear as reflected by cobalt (Co) and chromium (Cr) levels reduced in LC bearings, and if so, is this benefit offset by increased friction as assessed by implant-bone interface changes? We retrospectively reviewed 26 patients with LC resurfacings. We assessed Co and Cr levels in blood and urine, hip function, and radiographic adverse features. These data were compared with those from 26 patients with a similar resurfacing but with conventional clearance (CC) from a previous study. Minimum followup was 4.0 years (mean, 4.1 years; range, 4.0-4.7 years). Co and Cr ion comparisons showed three phases: in the first 2 months, there was no difference between the cohorts; at 2 to 24 months, the CC group showed higher levels; and subsequently, levels in the two groups converged. A mean Oxford hip score of 13 and step activity of 1.9 million cycles per year in the LC group were similar to those of the CC group. Cup radiolucencies were seen in three patients in the LC group and none in the CC group. Lower Co and Cr levels suggest lower wear in the LC resurfacings in the intermediate term, but the presence of radiolucencies raises the concern that higher bearing friction is affecting implant fixation. A larger clearance than the theoretically predicted ideal may be required to allow for minor manufacturing imperfections, component deformation, and progressive changes in the in vivo lubricant. Level III, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

  3. Resurfacing total hip replacement–a therapeutical approach in postmenopausal women with osteoporosis and hip arthrosis

    Science.gov (United States)

    Popescu, D; Ene, R

    2011-01-01

    Aim: Patients with incipient hip arthrosis may benefit from a relatively new therapeutical approach using resurfacing total hip replacement, but in those with associated osteoporosis, this type of surgical intervention is contraindicated, given the poor quality of osteoporotic bones. We assessed the efficacy of the antiosteoporotic pharmacological therapy to improve bone quality and bone strength in postmenopausal women diagnosed with hip arthrosis and osteoporosis thus facilitating the hip surgical intervention. Methods: We evaluated 20 postmenopausal women aged between 53–60 years diagnosed with osteoporosis according to the WHO criteria, by using dual–energy X–ray absorptiometry (DXA) for bone mineral density measurements. All these patients had low hip T score (osteopenia/ osteoporosis) and also incipient hip arthrosis. The surgical approach was delayed for 12 months and all the patients received bisphosphonate therapy with calcium and vitamin D supplements. DXA scans were performed after 12 months of therapy in all the patients. Results: A surgical intervention with resurfacing total hip replacement was performed in 12 of the 16 patients presenting with increasing BMD, 4 of them showing elements of rapidly advancing hip arthrosis to a stage that made this type of intervention impossible. We chose not to use this technique in the group with stable BMD (4 patients). All 12 women surgically treated had a favorable post–operative outcome without experiencing a femoral neck fracture during the surgical intervention or during the twelve–month follow–up. All 20 patients continued to receive bisphosphonate therapy. Conclusion: In postmenopausal women with osteoporosis and associated hip arthrosis, improving bone mass and bone quality with bisphosphonate therapy is necessary and important in order to allow hip arthroplasty, by using the technique of resurfacing, avoiding the risk of intra–operative fractures and with a favorable post–operative long

  4. Resurfacing total hip replacement--a therapeutical approach in postmenopausal women with osteoporosis and hip arthrosis.

    Science.gov (United States)

    Popescu, D; Ene, R; Cirstoiu, C

    2011-05-15

    Patients with incipient hip arthrosis may benefit from a relatively new therapeutical approach using resurfacing total hip replacement, but in those with associated osteoporosis, this type of surgical intervention is contraindicated, given the poor quality of osteoporotic bones. We assessed the efficacy of the antiosteoporotic pharmacological therapy to improve bone quality and bone strength in postmenopausal women diagnosed with hip arthrosis and osteoporosis thus facilitating the hip surgical intervention. We evaluated 20 postmenopausal women aged between 53-60 years diagnosed with osteoporosis according to the WHO criteria, by using dual-energy X-ray absorptiometry (DXA) for bone mineral density measurements. All these patients had low hip T score (osteopenia/ osteoporosis) and also incipient hip arthrosis. The surgical approach was delayed for 12 months and all the patients received bisphosphonate therapy with calcium and vitamin D supplements. DXA scans were performed after 12 months of therapy in all the patients. A surgical intervention with resurfacing total hip replacement was performed in 12 of the 16 patients presenting with increasing BMD, 4 of them showing elements of rapidly advancing hip arthrosis to a stage that made this type of intervention impossible. We chose not to use this technique in the group with stable BMD (4 patients). All 12 women surgically treated had a favorable post-operative outcome without experiencing a femoral neck fracture during the surgical intervention or during the twelve-month follow-up. All 20 patients continued to receive bisphosphonate therapy. In postmenopausal women with osteoporosis and associated hip arthrosis, improving bone mass and bone quality with bisphosphonate therapy is necessary and important in order to allow hip arthroplasty, by using the technique of resurfacing, avoiding the risk of intra-operative fractures and with a favorable post-operative long-term outcome.

  5. Are Females at Greater Risk for Revision Surgery After Hip Resurfacing Arthroplasty With the Articular Surface Replacement Prosthesis?

    Science.gov (United States)

    Donahue, Gabrielle S; Lindgren, Viktor; Galea, Vincent P; Madanat, Rami; Muratoglu, Orhun; Malchau, Henrik

    2016-10-01

    Female patients undergoing hip resurfacing arthroplasties may be at greater risk of revision surgery than males, but it is unclear whether this is related to sex or other factors. We focused our analysis on data from a prospective multicenter cohort study monitoring the ASR(TM) hip resurfacing arthroplasty prosthesis on the potential association of sex on patient-reported outcome measures (PROMs), metal ion levels, revision surgery, and presence of adverse local tissue reaction. As thousands of patients with the ASR(TM) prosthesis are still undergoing followup it is critical to optimize the protocol for monitoring these patients. We wished (1) to assess the associations between sex and implant survival, and adverse local tissue reaction; and (2) to report the differences between sexes in metal ion levels and patient-reported outcome measures. One thousand two hundred fifty-two patients (1390 hips) who underwent hip resurfacing arthroplasty with implantation of the ASR(TM) prosthesis from April 2003 to July 2010 were eligible for enrollment in a multicenter followup study of the ASR(TM) Hip Resurfacing System after the voluntary recall of this device was initiated by DePuy in 2010. Nine hundred seventy patients (1098 hips) were enrolled at a mean of 7 years after surgery, with a mean followup of 2 years (range, 1-3.5 years). Nine hundred fifty-eight patients (1084 hips) met the inclusion criteria: ability to provide informed consent, complete PROMs, and continued routine followup. A subset of patients (150 patients, 171 hips), who all were from one center, with annual metal artifact reduction sequence MRI were analyzed. Ninety-three percent of patients from this center had routine MRI performed. The EuroQoL (EQ-5D), Harris hip score (HHS), University of California Los Angeles (UCLA) activity score, VAS pain, radiographs, patient and surgery details, and blood cobalt and chromium levels were obtained. Cox regression analysis was conducted to identify factors

  6. Prospective study comparing functional outcomes and revision rates between hip resurfacing and total hip arthroplasty: preliminary results for 2 years

    Directory of Open Access Journals (Sweden)

    Régis Pailhé

    2013-07-01

    Full Text Available There is a need of independent prospective studies about modern generation of hip resurfacing implants. The aim of this propective observational study was to compare the functional outcomes and revision rates with hip resurfacing arthroplasty and total hip arthroplasty and to present the preliminary results at 2 years. Patients included were recruited prospectively in the Partial Pelvic Replacement Hip Project by a single surgeon between January 2007 and January 2010. Patients were assessed with the Harris Hip Score (HHS and Postel-Merle d’Aubigné (MDA score and Devane Score. The end point of the study was reoperation for any cause related to the prosthesis. At a mean follow up of 38.6 months there were a total of 142 patients with hip resurfacing (group 1 [100 Durom® (Zimmer Inc., Warsaw, IN, USA and 42 Birmingham Hip Resurfacing® (Smith & Nephew, Memphis, TN, USA] and 278 patients with total hip arthroplasty (group 2. The results showed significantly greater gain of HHS, MDA and Devane score with hip resurfacing procedures. However, considering all the complications, the rate was significantly higher in group 16.4% vs 1.79% in group 2 (P<0.0001. In group 1 we observed 6 complications only concerned males with Durom® implants. The follow up of this cohort is still on going and may deliver more information on the evolution of these results in time.

  7. Bone mineral density of the femoral neck in resurfacing hip arthroplasty

    DEFF Research Database (Denmark)

    Penny, Jeannette Østergaard; Ovesen, Ole; Brixen, Kim

    2010-01-01

    Resurfacing total hip arthroplasty (RTHA) may preserve the femoral neck bone stock postoperatively. Bone mineral density (BMD) may be affected by the hip position, which might bias longitudinal studies. We investigated the dependency of BMD precision on type of ROI and hip position....

  8. Hip resurfacing arthroplasty in treatment of avascular necrosis of the femoral head.

    Science.gov (United States)

    Pyda, Michał; Koczy, Bogdan; Widuchowski, Wojciech; Widuchowska, Małgorzata; Stołtny, Tomasz; Mielnik, Michał; Hermanson, Jacek

    2015-01-25

    Hip resurfacing is a conservative type of total hip arthroplasty but its use is controversial, especially in patients with osteonecrosis. The aim of this study was analysis of the clinical and radiographic outcomes of hip resurfacing in patients with osteonecrosis. Between 2007 and 2008, 30 hip resurfacing arthroplasties were performed due to osteoarthritis secondary to avascular necrosis of femoral head staged as Ficat III and IV. Patients were qualified to resurfacing arthroplasty when the extent of avascular necrosis using Kerboul's method was avascular necrosis and head-neck junction was >20°. All patients were evaluated clinically and radiologically before and 60 months after the operation. The mean Harris Hip Score (HHS) score increased from 47.8 to 94.25 (p<0.05). Physical activity level (University of California, Los Angeles activity score--UCLA activity score) improved from 3.7 to 7.55 (p<0.05). No implant migration was observed. Management of osteonecrosis of the hip with resurfacing arthroplasty seems to be effective in strictly-selected patients.

  9. Computer-assisted vs conventional mechanical jig technique in hip resurfacing arthroplasty.

    Science.gov (United States)

    Resubal, Jose Rafael E; Morgan, David A F

    2009-04-01

    To compare the effectiveness of computer-assisted surgery (CAS) and mechanical jig technique in hip resurfacing arthroplasty, we reviewed 176 hip resurfacing arthroplasty performed in 158 patients. The initial 131 hips were resurfaced using the conventional mechanical jig technique, and the remaining 45 hips with the CAS technique. The demographic data of the patients were similar for both techniques. Follow-up radiographs taken 2 months after the surgery showed patients in the CAS technique having a significantly better alignment of the femoral component on the frontal and sagittal planes. There was no difference in the risk of implant notching on the femoral neck for both techniques. The implant sizes were similar for both techniques; thus, the amount of bone stock preserved was not technique specific.

  10. Changes in bone mineral density of the acetabulum, femoral neck and femoral shaft, after hip resurfacing and total hip replacement

    DEFF Research Database (Denmark)

    Penny, J O; Brixen, K; Varmarken, J E

    2012-01-01

    It is accepted that resurfacing hip replacement preserves the bone mineral density (BMD) of the femur better than total hip replacement (THR). However, no studies have investigated any possible difference on the acetabular side. Between April 2007 and March 2009, 39 patients were randomised into ...

  11. Periacetabular Bone Mineral Density Changes After Resurfacing Hip Arthroplasty Versus Conventional Total Hip Arthroplasty. A Randomized Controlled DEXA Study

    NARCIS (Netherlands)

    Smolders, J.M.H.; Pakvis, D.F.; Hendrickx, B.W.; Verdonschot, Nicolaas Jacobus Joseph; van Susante, J.L.C.

    2013-01-01

    A randomized controlled trial was performed to evaluate acetabular bone mineral density (BMD) changes after hip resurfacing (RHA) versus an established conventional total hip arthroplasty (THA). A total of 71 patients were allocated randomly to receive either an RHA press-fit cobalt–chromium cup (n

  12. Recovery in horizontal gait after hip resurfacing vs. total hip arthroplasty at 6-month follow-up - a RCT study

    DEFF Research Database (Denmark)

    Jensen, Carsten; Aagaard, Per; Overgaard, Søren

    2012-01-01

    Background: Standard total hip arthroplasty (S-THA) is the established surgical treatment for patients older than 65 years with progressive osteoarthritis. However, implant survivorship curves decline more rapidly in patients younger than 50 years. Resurfacing total hip arthroplasty (R-THA) has t...

  13. Resultados preliminares da artroplastia do quadril metal-metal de superfície: análise dos primeiros 40 casos com seguimento médio de 3 anos Preliminary outcomes of hip metal-on-metal resurfacing arthroplasty: an analysis of the first 40 cases with mean follow-up time of 3 years

    Directory of Open Access Journals (Sweden)

    Mauricio de Moraes

    2008-01-01

    Full Text Available Quarenta quadris (39 pacientes foram submetidos à artroplastia total metal-metal de superficie "resurfacing" entre 2002 e 2005. Todos foram estudados e analisados clinicamente e radiograficamente. Foram utilizados critérios clínicos, no pré e pós-operatório, pela avaliação de D'Aubigné e Postel. Radiograficamente, as áreas de radiolucência ao redor do acetábulo foram classificadas de acordo com DeLee e Charnley e, no fêmur nas zonas descritas por Amstutz et al. A idade média foi de 54,40 anos. O seguimento mínimo foi de 14 meses e o máximo de 51(média de 37,36 meses. 94,44% dos resultados clínicos foram satisfatórios no pós-operatório. Ocorreram 2 casos de soltura asséptica. Não houve fratura do fêmur durante o seguimento. Os autores consideraram esta opção técnica e de implante satisfatória e, com bons resultados no seguimento médio de 3 anos.Forty hips (39 patients were submitted to metal-on-metal hip replacement (resurfacing between 2002 and 2005. Evaluation was provided by clinical examination and X-ray tests. The authors performed clinical evaluations before and after surgery. The specific criterion applied was the D'Aubigné and Postel's classification. X-ray images showed radiolucent lines around the acetabular component on the zones described by DeLee and Charnley and around the femoral component on the zones described by Amstutz et al. The mean age was 54.40 years. The minimum follow-up period was 14 months (range:12 to 51 months. The outcomes of 94.44% of the patients in the study were postoperatively rated as satisfactory. There were 2 cases of aseptic loose and no neck-femoral fractures during the follow-up period. The authors concluded that this technique and implant alternative is satisfactory, with good early outcomes in a mean follow-up time of three years.

  14. 21 CFR 888.3580 - Knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... resurfacing uncemented prosthesis. 888.3580 Section 888.3580 Food and Drugs FOOD AND DRUG ADMINISTRATION... § 888.3580 Knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis. (a) Identification. A knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis is a device made of...

  15. Computer navigation experience in hip resurfacing improves femoral component alignment using a conventional jig.

    Science.gov (United States)

    Morison, Zachary; Mehra, Akshay; Olsen, Michael; Donnelly, Michael; Schemitsch, Emil

    2013-11-01

    The use of computer navigation has been shown to improve the accuracy of femoral component placement compared to conventional instrumentation in hip resurfacing. Whether exposure to computer navigation improves accuracy when the procedure is subsequently performed with conventional instrumentation without navigation has not been explored. We examined whether femoral component alignment utilizing a conventional jig improves following experience with the use of imageless computer navigation for hip resurfacing. Between December 2004 and December 2008, 213 consecutive hip resurfacings were performed by a single surgeon. The first 17 (Cohort 1) and the last 9 (Cohort 2) hip resurfacings were performed using a conventional guidewire alignment jig. In 187 cases, the femoral component was implanted using the imageless computer navigation. Cohorts 1 and 2 were compared for femoral component alignment accuracy. All components in Cohort 2 achieved the position determined by the preoperative plan. The mean deviation of the stem-shaft angle (SSA) from the preoperatively planned target position was 2.2° in Cohort 2 and 5.6° in Cohort 1 (P = 0.01). Four implants in Cohort 1 were positioned at least 10° varus compared to the target SSA position and another four were retroverted. Femoral component placement utilizing conventional instrumentation may be more accurate following experience using imageless computer navigation.

  16. Computer navigation experience in hip resurfacing improves femoral component alignment using a conventional jig

    Directory of Open Access Journals (Sweden)

    Zachary Morison

    2013-01-01

    Full Text Available Background:The use of computer navigation has been shown to improve the accuracy of femoral component placement compared to conventional instrumentation in hip resurfacing. Whether exposure to computer navigation improves accuracy when the procedure is subsequently performed with conventional instrumentation without navigation has not been explored. We examined whether femoral component alignment utilizing a conventional jig improves following experience with the use of imageless computer navigation for hip resurfacing. Materials and Methods:Between December 2004 and December 2008, 213 consecutive hip resurfacings were performed by a single surgeon. The first 17 (Cohort 1 and the last 9 (Cohort 2 hip resurfacings were performed using a conventional guidewire alignment jig. In 187 cases, the femoral component was implanted using the imageless computer navigation. Cohorts 1 and 2 were compared for femoral component alignment accuracy. Results:All components in Cohort 2 achieved the position determined by the preoperative plan. The mean deviation of the stem-shaft angle (SSA from the preoperatively planned target position was 2.2° in Cohort 2 and 5.6° in Cohort 1 ( P = 0.01. Four implants in Cohort 1 were positioned at least 10° varus compared to the target SSA position and another four were retroverted. Conclusions: Femoral component placement utilizing conventional instrumentation may be more accurate following experience using imageless computer navigation.

  17. Computer-assisted hip resurfacing planning using Lie group shape models.

    Science.gov (United States)

    Hefny, Mohamed S; Rudan, John F; Ellis, Randy E

    2015-06-01

    Hip resurfacing is a surgical option for osteoarthritis young and active patients. Early failures has been reported due to improper implant placement. Computer-assisted surgery is a promising avenue for more successful procedures. This paper presents a novel automatic surgical planning for computer-assisted hip resurfacing procedures. The plan defined the femoral head axis that was used to place the implant. The automatic planning was based on a Lie group statistical shape model. A statistical shape model was constructed using 50 femurs from osteoarthritis patients who underwent computer-assisted hip resurfacing. The model was constructed using product Lie groups representation of shapes and nonlinear analysis on the manifold of shapes. A surgical plan was drawn for the derived base shape. The base shape was transformed to 14 femurs with known manual plans. The transformed base plan was used as the computed plan for each femur. Both actual and computed plans were compared. The method showed a success by computing plans that differ from the actual plans within the surgical admissible ranges. The minimum crossing distance between the two plans had a mean of 0.75 mm with a standard deviation of 0.54 mm. The angular difference between the two plans had the mean of 5.94° with a standard deviation of 2.145.94°. Product Lie groups shape models were proved to be successful in automatic planning for hip resurfacing computer-assisted surgeries. The method can be extended to other orthopedic and general surgeries.

  18. Structure and corrosion resistance of Co-Cr-Mo alloy used in Birmingham Hip Resurfacing system.

    Science.gov (United States)

    Dobruchowska, Ewa; Paziewska, Monika; Przybyl, Krzysztof; Reszka, Kazimierz

    2017-01-01

    The endoprostheses made of cobalt-chromium-molybdenum (Co-Cr-Mo) alloys belong to the group of the most popular metallic implants used for reconstruction of hip joints. For such biomaterials, the primary goal is a correct and long-term functioning in the aggressive environment of body fluids. Therefore, the purpose of this study was to examine both the morphology and the corrosion resistance of implants made of the cobalt alloy used in Birmingham Hip Resurfacing (BHR) system (Smith & Nephew). For comparative purposes, the electrochemical studies were done for the nitrided stainless steel - Orthinox. Observations of the microstructure of the material under investigation were performed by means of the optical metallographic microscope and the scanning electron microscope. Furthermore, Energy Dispersive X-ray Spectroscopy was used to analyse the chemical composition of the endoprosthesis. Characterisation and evaluation of electrochemical corrosion resistance of the selected alloys were performed by potentiodynamic polarisation tests. The structural studies confirmed that Co-Cr-Mo (BHR system) is characterised by a typical dendritic microstructure with carbide precipitates, mainly M23C6, within the interdendritic areas. The results of the polarisation measurements showed that the cobalt alloy investigated exhibits lower corrosion potential than Orthinox in the utilised environments (3% NaCl, simulated body fluid - Hank's Body Fluid). However, the high passivation ability of the Co-Cr-Mo alloy, as well as its resistance to the initiation and propagation of localised corrosion processes, indicate that this material is significantly more appropriate for long-term implants.

  19. Periprosthetic fractures in the resurfaced hip--A case report and review of the literature.

    LENUS (Irish Health Repository)

    Brennan, Stephen A

    2013-02-01

    Traumatic periprosthetic fractures adjacent a hip resurfacing prosthesis are rare. When proximal fractures are encountered the obvious surgical solution is to revise to a large head stemmed femoral component. A previously well functioning implant may however be retained as various non-operative and operative treatment options exist. This paper reports the case history of a traumatic periprosthetic fracture successfully treated with cannulated screw fixation and reviews the current literature.

  20. Direct to consumer advertising via the Internet, a study of hip resurfacing.

    Science.gov (United States)

    Ogunwale, B; Clarke, J; Young, D; Mohammed, A; Patil, S; Meek, R M D

    2009-02-01

    With increased use of the internet for health information and direct to consumer advertising from medical companies, there is concern about the quality of information available to patients. The aim of this study was to examine the quality of health information on the internet for hip resurfacing. An assessment tool was designed to measure quality of information. Websites were measured on credibility of source; usability; currentness of the information; content relevance; content accuracy/completeness and disclosure/bias. Each website assessed was given a total score, based on number of scores achieved from the above categories websites were further analysed on author, geographical origin and possession of an independent credibility check. There was positive correlation between the overall score for the website and the score of each website in each assessment category. Websites by implant companies, doctors and hospitals scored poorly. Websites with an independent credibility check such as Health on the Net (HoN) scored twice the total scores of websites without. Like other internet health websites, the quality of information on hip resurfacing websites is variable. This study highlights methods by which to assess the quality of health information on the internet and advocates that patients should look for a statement of an "independent credibility check" when searching for information on hip resurfacing.

  1. Outcomes of hip resurfacing in a professional dancer: a case report.

    Science.gov (United States)

    Dunleavy, Kim

    2012-02-01

    A new surgical option (hip resurfacing arthroplasty) is now available for younger patients with hip osteoarthritis. A more aggressive rehabilitation program than the typical total hip arthroplasty protocol is needed for active individuals. This case report describes interventions used to maximize function in a 46-year-old professional dancer after hip resurfacing with a progressive therapeutic exercise program. Exercise choices were selected to address dance-specific requirements while respecting healing of the posterior capsular incision. Strengthening focused on hip abduction, extension, and external rotation. Precautions included avoiding gluteal stretching until 6 months. Pelvic alignment and weight-bearing distribution were emphasized. The patient was able to return to rehearsal by 7 months, at which time strength was equivalent to the unaffected leg. Range of motion reached unaffected side values at week 8 for internal rotation, week 11 for extension, week 13 for adduction, and week 28 for flexion. External rotation and abduction were still limited at 1 year, which influenced pelvic alignment with resultant pain on the unaffected side. Functional and impairment outcomes are presented with timelines to provide a basis for postoperative benchmarks for active clients after hip resurfacing. Although this case report presents a dance-specific program, exercise progressions for other active individuals may benefit from similar exercise intensity and sports-specific focus. Future rehabilitation programs should take into account possible flexion and external rotation range limitations and the need for gluteal muscle strengthening along with symmetry and pelvic alignment correction. Long-term studies investigating intensity of rehabilitation are warranted for patients intending to participate in higher level athletic activity.

  2. Outcome of Revision Total Hip Arthroplasty in Management of Failed Metal-on-Metal Hip Arthroplasty.

    Science.gov (United States)

    Rahman, Wael A; Amenábar, Tomás; Hetaimish, Bandar M; Safir, Oleg A; Kuzyk, Paul R; Gross, Allan E

    2016-11-01

    This is a retrospective review of the functional outcomes and complications of revision total hip arthroplasty (THA) of failed metal-on-metal (MoM) hip arthroplasty. A total of 20 revision THAs were performed in 19 patients. Of them, 2 cases were failed hip resurfacing, and 18 cases were failed (MoM) THA. The mean age at revision (THA) was 59.35 years (standard deviation [SD] 9.83). The mean follow-up was 45 months (SD 13.98). The indications of revision were aseptic loosening of acetabular component without adverse local tissue reaction (ALTR; 10 hips), aseptic loosening of the acetabular and femoral components without ALTR (1 hip), painful hip associated with ALTR (6 hips), iliopsoas impingement associated with a large-diameter femoral head or malpositioned acetabular component (3 hips). The acetabular components were revised in 18 hips using Trabecular Metal Modular cups. The femoral components were revised in 3 hips. A constrained acetabular liner was used in 5 hips. The Harris hip score significantly improved from 48.4 (SD 12.98) to 83.25 (SD 10.08). There were 2 complications (1 foot drop and 1 superficial infection) and 1 failure (recurrent dislocation) that required revision to a constrained liner. Early results of revision THA of failed MoM hip arthroplasty showed improvement in pain and functional outcome. No case of failed bone ingrowth was noted with the use of Trabecular Metal Modular cups. Extensive soft tissue and abductor muscles dysfunctions were common. A constrained acetabular component with repair of the hip abductors might be beneficial. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. High incidence of pseudotumours after hip resurfacing even in low risk patients; results from an intensified MRI screening protocol.

    NARCIS (Netherlands)

    Weegen, W. van der; Smolders, J.M.; Sijbesma, T.; Hoekstra, H.J.; Brakel, K.; Susante, J.L.C. van

    2013-01-01

    We intensified our screening protocol for the presence of pseudotumours in a consecutive series of patients with a hip resurfacing arthroplasty (HRA), to establish whether we should be alert to the presence of 'silent' pseudotumours. Patients categorised with high risk (11 hips) and low risk (10

  4. 21 CFR 888.3590 - Knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... uncemented prosthesis. 888.3590 Section 888.3590 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis. (a) Identification. A knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis is a device intended to be implanted...

  5. Reliability of using DXA around RTHAs. Bone Mineral Density of the femoral neck in resurfacing hip arthroplasty

    DEFF Research Database (Denmark)

    Penny, Jeannette Østergaard; Ovesen, Ole; Brixen, Kim

    2010-01-01

      Background and purpose: Resurfacing Total Hip Arthroplasty (RTHA) may preserve the femoral neck bone-stock post-operatively. Bone Mineral Density (BMD), could theoretically be affected by the hip-position, and bias longitudinal studies. We aimed to investigate BMD precision dependency on type...... of ROI and position of hip. Method: We DXA scanned the femoral neck of 15 resurfacing patients twice with the hip in 3 different rotations; 15° internal, neutral, and 15° external. For each position BMD was analyzed with 3 different surface area models. One model measured BMD in the total femoral neck......, the second model divided the neck in two and the third model had 6 divisions. Results: When all hip positions were pooled a mean Coefficient of variation (CV) of 3.1%, 3.6% and 4.6% was found in the 1, 2 and 6-region models, respectively, The external rotated hip position was less reproducible. When the hip...

  6. Bone mineral density of the femoral neck in resurfacing hip arthroplasty.

    Science.gov (United States)

    Penny, Jeannette Østergaard; Ovesen, Ole; Brixen, Kim; Varmarken, Jens-Erik; Overgaard, Søren

    2010-06-01

    Resurfacing total hip arthroplasty (RTHA) may preserve the femoral neck bone stock postoperatively. Bone mineral density (BMD) may be affected by the hip position, which might bias longitudinal studies. We investigated the dependency of BMD precision on type of ROI and hip position. We DXA-scanned the femoral neck of 15 resurfacing patients twice with the hip in 3 different rotations: 15 degrees internal, neutral, and 15 degrees external. For each position, BMD was analyzed with 3 surface area models. One model measured BMD in the total femoral neck, the second model divided the neck in two, and the third model had 6 divisions. When all hip positions were pooled, average coefficients of variation (CVs) of 3.1%, 3.6%, and 4.6% were found in the 1-, 2-, and 6-region models, respectively. The externally rotated hip position was less reproducible. When rotating in increments of 15 degrees or 30 degrees , the average CVs rose to 7.2%, 7.3%, and 12% in the 3 models. Rotation affected the precision most in the model that divided the neck in 6 subregions, predominantly in the lateral and distal regions. For larger-region models, some rotation could be allowed without compromising the precision. If hip rotation is strictly controlled, DXA can reliably provide detailed topographical information about the BMD changes around an RTHA. As rotation strongly affects the precision of the BMD measurements in small regions, we suggest that a less detailed model should be used for analysis in studies where the leg position has not been firmly controlled.

  7. Computer navigation vs conventional mechanical jig technique in hip resurfacing arthroplasty: a meta-analysis based on 7 studies.

    Science.gov (United States)

    Liu, Hao; Li, Lin; Gao, Wei; Wang, Meilin; Ni, Chunhui

    2013-01-01

    The studies on the accuracy of femoral component in hip resurfacing arthroplasty with the help of computer-assisted navigation were not consistent. This study aims to assess at the functional outcomes after computer navigation in hip resurfacing arthroplasty by systematically reviewing and meta-analyzing the data, which were searched up to December 2011 in PubMed, MEDLINE, EMBASE, MetaMed, EBSCO HOST, and the Web site of Google scholar. Totally, 197 articles about hip resurfacing arthroplasty were collected; finally, 7 articles met the inclusion criteria and were included in this meta-analysis (520 patients with 555 hip resurfacing arthroplasty). The odds ratio for the number of outliers was 0.155 (95% confidence interval, 0.048-0.498; P < .003). In conclusion, this meta-analysis suggests that the computer-assisted navigation system makes the femoral component positioning in hip resurfacing arthroplasty easier and more precise. Crown Copyright © 2013. Published by Elsevier Inc. All rights reserved.

  8. Similar range of motion and function after resurfacing large-head or standard total hip arthroplasty

    DEFF Research Database (Denmark)

    Penny, Jeannette Østergaard; Ovesen, Ole; Varmarken, Jens-Erik

    2013-01-01

    BACKGROUND AND PURPOSE: Large-size hip articulations may improve range of motion (ROM) and function compared to a 28-mm THA, and the low risk of dislocation allows the patients more activity postoperatively. On the other hand, the greater extent of surgery for resurfacing hip arthroplasty (RHA......° (35), 232° (36), and 225° (30) respectively, but the differences were not statistically significant. The 3 groups were similar regarding Harris hip score, UCLA activity score, step rate, and sick leave. INTERPRETATION: Head size had no influence on range of motion. The lack of restriction allowed...... for large articulations did not improve the clinical and patient-perceived outcomes. The more extensive surgical procedure of RHA did not impair the rehabilitation. This project is registered at ClinicalTrials.gov under # NCT01113762....

  9. A comparison of conventional guidewire alignment jigs with imageless computer navigation in hip resurfacing arthroplasty.

    Science.gov (United States)

    Olsen, Michael; Chiu, Mark; Gamble, Patrick; Boyle, Richard A; Tumia, Nezar; Schemitsch, Emil H

    2010-08-04

    Correct positioning of the initial femoral guidewire is vital in order to prepare the femoral head properly for hip resurfacing. The purpose of the present investigation was to determine the accuracy and precision of the placement of the initial femoral guidewire with use of conventional alignment jigs and to compare the results with those of imageless computer navigation. Five commercially available jigs (two lateral pin jigs, two neck centering jigs, and one head planing jig) were obtained. Four surgeons used each jig and navigation three times to insert a guidewire in 10 degrees of relative valgus and neutral version into individual synthetic femora. A single surgeon then used each jig three times to align the initial guidewire in 10 degrees of relative valgus and neutral version in each of ten human cadaver femora. Radiographs of the synthetic and human femora were made to assess and compare guidewire inclination and version between conventional instrumentation and navigation. Navigation provided ranges of error in the coronal guidewire alignment of up to eight times less than the conventional jigs, but both methods provided similar ranges of error for version. In both arms of the study, there were significant differences in coronal alignment accuracy between the two neck centering jigs. Next to navigation, one lateral pin jig provided the most accurate coronal placement of the initial guidewire whereas one neck centering jig provided the most precise coronal placement of the guidewire. Navigation was similar to conventional jigs in terms of the accuracy and precision of guidewire version. In hip resurfacing arthroplasty, the choice of a femoral alignment device may influence the accuracy and precision of guidewire insertion, ultimately impacting femoral component placement. Imageless computer navigation can facilitate accurate and precise coronal alignment of the initial femoral guidewire, superior to that of conventional instrumentation. The results of this

  10. How accurate is image-free computer navigation for hip resurfacing arthroplasty? An anatomical investigation

    International Nuclear Information System (INIS)

    Schnurr, C.; Nessler, J.; Koenig, D.P.; Meyer, C.; Schild, H.H.; Koebke, J.

    2009-01-01

    The existing studies concerning image-free navigated implantation of hip resurfacing arthroplasty are based on analysis of the accuracy of conventional biplane radiography. Studies have shown that these measurements in biplane radiography are imprecise and that precision is improved by use of three-dimensional (3D) computer tomography (CT) scans. To date, the accuracy of image-free navigation devices for hip resurfacing has not been investigated using CT scans, and anteversion accuracy has not been assessed at all. Furthermore, no study has tested the reliability of the navigation software concerning the automatically calculated implant position. The purpose of our study was to analyze the accuracy of varus-valgus and anteversion using an image-free hip resurfacing navigation device. The reliability of the software-calculated implant position was also determined. A total of 32 femoral hip resurfacing components were implanted on embalmed human femurs using an image-free navigation device. In all, 16 prostheses were implanted with the proposed position generated by the navigation software; the 16 prostheses were inserted in an optimized valgus position. A 3D CT scan was undertaken before and after operation. The difference between the measured and planned varus-valgus angle averaged 1 deg (mean±standard deviation (SD): group I, 1 deg±2 deg; group II, 1 deg±1 deg). The mean±SD difference between femoral neck anteversion and anteversion of the implant was 4 deg (group I, 4 deg±4 deg; group II, 4 deg±3 deg). The software-calculated implant position differed 7 deg±8 deg from the measured neck-shaft angle. These measured accuracies did not differ significantly between the two groups. Our study proved the high accuracy of the navigation device concerning the most important biomechanical factor: the varus-valgus angle. The software calculation of the proposed implant position has been shown to be inaccurate and needs improvement. Hence, manual adjustment of the

  11. Recovery in mechanical muscle strength following resurfacing vs standard total hip arthroplasty - a randomised clinical trial

    DEFF Research Database (Denmark)

    Jensen, Carsten; Aagaard, Per; Overgaard, S

    2011-01-01

    in maximal lower limb muscle strength (in 2/6 muscle groups) compared to S-THA. Notably, the attenuated strength recovery following R-THA was most markedly manifested in the late phase (1 yr) of post-surgical recovery, and appeared to be due to the detachment of the lower half of the gluteus maximus muscle...... randomised into (A) standard total hip arthroplasty (S-THA) and (B) resurfacing total hip arthroplasty (R-THA). Pre-surgery assessment and follow-up were conducted (8, 26 and 52 wks). Maximal isometric muscle strength (Nm) and between-limb asymmetry for the knee extensors/flexors, hip adductors....../abductors, hip extensors/flexors were analysed. RESULTS: Maximal knee extensor and hip abductor strength were higher in S-THA than R-THA at 52 wks post-surgery (P ≤ 0.05) and hip extensors tended to be higher in S-THA at 52 wks (P = 0.06). All muscle groups showed substantial between-limb strength asymmetry (7...

  12. Revision rate of Birmingham Hip Resurfacing arthroplasty: comparison of published literature and arthroplasty register data.

    Science.gov (United States)

    Schuh, Reinhard; Neumann, Daniel; Rauf, Rauend; Hofstaetter, Jochen; Boehler, Nikolaus; Labek, Gerold

    2012-07-01

    Hip resurfacing arthroplasty has gained popularity for treating young and active patients who have arthritis. There are two major data sources for assessing outcome and revision rate after total joint arthroplasty: sample-based clinical trials and national arthroplasty registers. The purpose of this study was to evaluate the outcome of the Birmingham Hip Resurfacing (BHR) arthroplasty in terms of revision rate as reported in clinical studies and recorded by national arthroplasty registers. A comprehensive literature research was performed from English-language, peer-reviewed journals and annual reports from national joint arthroplasty registers worldwide. Only publications from MEDLINE-listed journals were included. The revision rate was used as the primary outcome parameter. In order to allow for direct comparison of different data sets, calculation was based on revisions per 100 observed component years. For statistical analysis, confidence intervals (CI) were calculated. A total of 18,708 implants, equivalent to 106,565 observed component years, were analysed in the follow-up studies. The register reports contained 9,806 primary cases corresponding to 44,294 observed component years. Statistical analysis revealed a significant difference in revisions per 100 observed component years between the development team (0.27; CI: 0.14-0.40) and register data (0.74; CI: 0.72-0.76). The BHR arthroplasty device shows good results in terms of revision rate in register data as well as in clinical studies. However, the excellent results reported by the development team are not reproducible by other surgeons. Based on the results of our study, we believe that comprehensive national arthroplasty registers are the most suitable tool for assessing hip arthroplasty revision rate.

  13. A randomised controlled trial of total hip arthroplasty versus resurfacing arthroplasty in the treatment of young patients with arthritis of the hip joint.

    Science.gov (United States)

    Achten, Juul; Parsons, Nick R; Edlin, Richard P; Griffin, Damian R; Costa, Matthew L

    2010-01-14

    Hip replacement (arthroplasty) surgery is a highly successful treatment for patients with severe symptomatic arthritis of the hip joint. For older patients, several designs of Total Hip Arthroplasty have shown excellent results in terms of both function and value for money. However, in younger more active patients, there is approximately a 50% failure rate at 25 years for traditional implants. Hip resurfacing is a relatively new arthroplasty technique. In a recent review of the literature on resurfacing arthroplasty it was concluded that the short-term functional results appear promising but some potential early disadvantages were identified, including the risk of femoral neck fracture and collapse of the head of the femur. The aim of the current study is to assess whether there is a difference in functional hip scores at one year post-operation between Total Hip Arthroplasty and Resurfacing Arthroplasty. Secondary aims include assessment of complication rates for both procedures as well cost effectiveness. All patients medically fit for surgery and deemed suitable for a resurfacing arthroplasty are eligible to take part in this study. A randomisation sequence will be produced and administered independently. After consenting, all patients will be clinically reviewed and hip function, quality of life and physical activity level will be assessed through questionnaires. The allocated surgery will then be performed with the preferred technique of the surgeon. Six weeks post-operation hip function will be assessed and complications recorded. Three, six and 12 months post-operation hip function, quality of life and physical activity level will be assessed. Additional information about patients' out-of-pocket expenses will also be collected. Current Controlled Trials ISRCTN33354155. UKCLRN portfolio ID 4093.

  14. Hip resurfacing using a modified lateral approach with limited splitting of the gluteus medius muscle results in significant impairment of hip abductor strength.

    Science.gov (United States)

    Moussazadeh, A J; Kohlhof, H; Wirtz, D C; Wimmer, M D; Randau, T M; Wölk, T; Gravius, S

    2013-01-01

    A lateral, transgluteal approach for hip resurfacing carries the risk of approach-related weakening of the hip abductors due to unsuccessful re-adaptation of the gluteal muscles to the greater trochanter or to injury to the inferior nerve branch of the superior gluteal nerve. We investigated whether hip resurfacing using a soft tissue-sparing, modified transgluteal approach with limited cranial splitting of the gluteus medius muscle reduces hip abductor strength and the risk of approach-related injury to the superior gluteal nerve. Thirty-one patients (14 female, 17 male; mean age 53.5 ± 5.2 years) underwent hip resurfacing using a modified transgluteal approach with limited cranial splitting of the gluteus medius muscle. Nerve conduction signals were measured by surface electromyography (EMG), hip abductor strength by isokinetic testing a mean 36.2 months (± 11 mos) after surgery. The unoperated side was used as control. Surface EMG disclosed no neural lesions of the inferior branch of the superior gluteal nerve. Isokinetics revealed a significant reduction in muscle strength on the operated versus the contralateral side. Even a limited incision of the gluteus medius muscle resulted in significant impairment of hip abductor strength 2.5 years after surgery.

  15. Dual energy X-ray absorptiometry analysis of peri-prosthetic stress shielding in the Birmingham resurfacing hip replacement.

    LENUS (Irish Health Repository)

    Harty, J A

    2012-02-03

    INTRODUCTION: Numerous reports in the literature refer to the femoral neck fracture rate in hip resurfacing. The aim of this study was to determine the bone mineral density and evidence of stress shielding around the femoral component of the Birmingham resurfacing prosthesis. MATERIAL AND METHODS: Twenty-eight patients with primary unilateral osteoarthritis had a Birmingham resurfacing prosthesis. DEXA analysis of the proximal femur and femoral neck was performed and compared with the opposite unaffected side. RESULTS: Total periprosthetic bone mineral density was 0.49% greater than the control, but this did not achieve statistical significance. Although the BMD of the femoral neck was slightly increased on the prosthetic side (1.002 g\\/cm2) as opposed to the control side, this difference did not reach statistical significance. CONCLUSION: The Birmingham resurfacing prosthesis does not appear to reduce femoral neck bone mineral density in comparison to the normal femoral neck bone density. We conclude that femoral neck fractures are unlikely to be due to stress shielding related to the prosthesis.

  16. Inferior outcome after hip resurfacing arthroplasty than after conventional arthroplasty. Evidence from the Nordic Arthroplasty Register Association (NARA) database, 1995 to 2007

    DEFF Research Database (Denmark)

    Johanson, Per-Erik; Fenstad, Anne Marie; Furnes, Ove

    2010-01-01

    The reported outcomes of hip resurfacing arthroplasty (HRA) vary. The frequency of this procedure in Denmark, Norway, and Sweden is low. We therefore determined the outcome of HRA in the NARA database, which is common to all 3 countries, and compared it to the outcome of conventional total hip...

  17. Reliability of using DXA around RTHAs. Bone Mineral Density of the femoral neck in resurfacing hip arthroplasty. Precision biased by region of interest and rotation of the hip

    DEFF Research Database (Denmark)

    Penny, Jeannette Østergaard; Varmarken, Jens-Erik; Ovesen, Ole

    2009-01-01

    the hip was rotated in increments of 15° and 30°, the mean CVs rose to 7.2%, 7.3% and 11.8%.  Rotation affected the precision most in the model that divided the neck in 6 sub regions, predominantly in the lateral and distal regions. For larger-region models, some rotation could be allowed without......  Introduction:  Resurfacing Total Hip Arthroplasty (RTHA) may preserve the femoral neck bone-stock post-operatively. Bone Mineral Density (BMD), could theoretically be affected by the hip-position, and bias longitudinal studies. We aimed to investigate BMD precision dependency on type of ROI...... and position of hip.   Method and Materials  We DXA scanned the femoral neck of 15 resurfacing patients twice with the hip in 3 different rotations; 15° internal, neutral, and 15° external. For each position BMD was analyzed with 3 different surface area models. One model measured BMD in the total femoral neck...

  18. Nano-analyses of wear particles from metal-on-metal and non-metal-on-metal dual modular neck hip arthroplasty.

    Science.gov (United States)

    Xia, Zhidao; Ricciardi, Benjamin F; Liu, Zhao; von Ruhland, Christopher; Ward, Mike; Lord, Alex; Hughes, Louise; Goldring, Steven R; Purdue, Edward; Murray, David; Perino, Giorgio

    2017-04-01

    Increased failure rates due to metallic wear particle-associated adverse local tissue reactions (ALTR) is a significant clinical problem in resurfacing and total hip arthroplasty. Retrieved periprosthetic tissue of 53 cases with corrosion/conventional metallic wear particles from 285 revision operations for ALTR was selected for nano-analyses. Three major classes of hip implants associated with ALTR, metal-on-metal hip resurfacing arthroplasty (MoM HRA) and large head total hip replacement (MoM LHTHA) and non-metal-on-metal dual modular neck total hip replacement (Non-MoM DMNTHA) were included. The size, shape, distribution, element composition, and crystal structure of the metal particles were analyzed by conventional histological examination and electron microscopy with analytic tools of 2D X-ray energy dispersive spectrometry and X-ray diffraction. Distinct differences in size, shape, and element composition of the metallic particles were detected in each implant class which correlate with the histological features of severity of ALTR and variability in implant performance. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  19. Revision of failed hip resurfacing to total hip arthroplasty rapidly relieves pain and improves function in the early post operative period

    Directory of Open Access Journals (Sweden)

    Muirhead-Allwood Sarah K

    2010-11-01

    Full Text Available Abstract We reviewed the results of 25 consecutive patients who underwent revision of a hip resurfacing prosthesis to a total hip replacement. Revisions were performed for recurrent pain and effusion, infection and proximal femoral fractures. Both components were revised in 20 cases. There were 12 male and 13 female patients with average time to revision of 34.4 and 26.4 months respectively. The mean follow up period was 12.7 months (3 to 31. All patients reported relief of pain and excellent satisfaction scores. Two patients experienced stiffness up to three months post operatively. Pre operative Oxford, Harris and WOMAC hip scores were 39.1, 36.4 and 52.2 respectively. Mean post operative scores at last follow up were 17.4, 89.8 and 6.1 respectively (p

  20. Changes of the bone mineral density in proximal femur following total hip resurfacing arthroplasty in osteonecrosis of femoral head.

    Science.gov (United States)

    Lian, Yong-yun; Pei, Fu-xing; Yoo, Myung-chul; Cheng, Jing-qiu; Fatou, Camara-yagouba

    2008-04-01

    Total hip resurfacing arthroplasty (THRA) is being performed with increasing frequency for osteonecrosis of femoral head (ONFH). To evaluate femoral bone remodeling in ONFH after THRA and determine the impact of stem-neck angle (SNA) of inserted femoral component on bone remodeling, we monitored the changes in BMD in proximal femur in 23 patients with ONFH after surgery. Patients were divided into group A (SNA >or= 5 degrees ) and group B (SNA < 5 degrees ). The BMD was measured in seven Gruen zones and two neck zones using dual-energy X-ray absorptiometry preoperatively, then at 3, 6, 12, and 24 months after surgery. At all ROIs, the BMD decreased significantly by 3 months postoperatively. The BMD ceased to decrease and reversed by 6 months. The BMD in neck increased significantly in group A, compared with group B at 24 months. The BMD increased 2% at ROI1 at 24 months in both groups, and at ROI7, the BMD in group A reversed to baseline value by 6 months and increased 5.81% at 24 months. These findings implied that the bone stock of proximal femur in ONFH can be well reserved after total hip resurfacing arthroplasty with valgus positioning of the femoral component.

  1. Breast milk metal ion levels in a young and active patient with a metal-on-metal hip prosthesis.

    Science.gov (United States)

    Nelis, Raymond; de Waal Malefijt, Jan; Gosens, Taco

    2013-01-01

    Metal-on-metal resurfacing arthroplasty of the hip has been used increasingly over the last 10 years in younger active patients. The dissolution of the metal wear particles results in measurable increases in cobalt and chromium ions in the serum and urine of patients with a metal-on-metal bearing. We measured the cobalt, chromium, and molybdenum ion levels in urine; serum; and breast milk in a young and active patient with a metal-on-metal hip prosthesis after a pathologic fracture of the femoral neck. Metal-on-metal hip prosthesis leads to increasing levels of molybdenum in breast milk in the short-term follow-up. There are no increasing levels of chromium and cobalt ions in breast milk. Besides the already known elevated concentrations in serum of chromium and cobalt after implantation of a metal-on-metal hip prosthesis, we found no increasing levels of chromium and cobalt in urine. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Clinical and radiological evolution of Intervened patients of total arthroplasty of hip with prostheses of resuperficialization metal-metal - Preliminary report

    International Nuclear Information System (INIS)

    Galvan Villamarin, Fernando; Bernal Torres, Fabio A; Paez, Jose Mauricio and others

    2006-01-01

    The articular degeneration of the hip in young patients requires including therapeutical alternatives for the management of this population. The resurfacing prostheses with metal-metal surfaces is an alternative for this type of patients. Reports with short and medium follow up are very promising, besides the different studies of laboratory that bear, the theoretical bases for their success. In this descriptive study, observational cases series type is described the radiological and clinical evolution of patients intervened of total arthroplasty of hip with resurfacing prostheses metal-metal in the hospital el Tunal of Bogota. The results of 31 hips are presented (27 patients) with an age average of 50 years old and a medium follow up of 16 months, with a good post surgical functional result with a median of 96 in the Harris Scores. The complications presented in the patient series are described and their relation with the different factors analyzed

  3. Edge loading in metal-on-metal hips: low clearance is a new risk factor.

    Science.gov (United States)

    Underwood, Richard J; Zografos, Angelos; Sayles, Ritchie S; Hart, Alister; Cann, Philippa

    2012-03-01

    The revision rate of large head metal-on-metal and resurfacing hips are significantly higher than conventional total hip replacements. The revision of these components has been linked to high wear caused by edge loading; which occurs when the head-cup contact patch extends over the cup rim. There are two current explanations for this; first, there is loss of entrainment of synovial fluid resulting in breakdown of the lubricating film and second, edge loading results in a large local increase in contact pressure and consequent film thickness reduction at the cup rim, which causes an increase in wear. This paper develops a method to calculate the distance between the joint reaction force vector and the cup rim--the contact patch centre to rim (CPCR) distance. However, the critical distance for the risk of edge loading is the distance from the contact patch edge to rim (CPER) distance. An analysis of explanted hip components, divided into edge worn and non-edge-worn components showed that there was no statistical difference in CPCR values, but the CPER value was significantly lower for edge worn hips. Low clearance hips, which have a more conformal contact, have a larger diameter contact patch and thus are more at risk of edge loading for similarly positioned hips.

  4. Treatment of osteochondral defects of the talus with a metal resurfacing inlay implant after failed previous surgery: a prospective study

    NARCIS (Netherlands)

    van Bergen, C. J. A.; van Eekeren, I. C. M.; Reilingh, M. L.; Sierevelt, I. N.; van Dijk, C. N.

    2013-01-01

    We have evaluated the clinical effectiveness of a metal resurfacing inlay implant for osteochondral defects of the medial talar dome after failed previous surgical treatment. We prospectively studied 20 consecutive patients with a mean age of 38 years (20 to 60), for a mean of three years (2 to 5)

  5. Bone mineral density of the proximal femur after hip resurfacing arthroplasty: 1-year follow-up study

    Directory of Open Access Journals (Sweden)

    Anttila Esa

    2011-05-01

    Full Text Available Abstract Background Hip resurfacing arthroplasty (HRA is considered a bone-preserving procedure and may eliminate proximal femoral stress shielding and osteolysis. However, in addition to implant-related stress-shielding factors, various patient-related factors may also have an effect on bone mineral density (BMD of the proximal femur in patients with HRA. Thus, we studied the effects of stem-neck angle, demographic variables, and physical functioning on the BMD of the proximal femur in a one-year follow-up. Methods Thirty three patients (9 females and 24 males with a mean (SD age of 55 (9 years were included in the study. BMD was measured two days and 3, 6, and 12 months postoperatively and 10 regions of interest (ROI were used. Stem-neck angle was analyzed from anteroposterior radiographs. Results Three months postoperatively, BMD decreased in six out of 10 regions of interest (ROI on the side operated on and in one ROI on the control side (p Conclusions After an early drop, the BMD of the upper femur was restored and even exceeded the preoperative level at one year follow-up. From a clinical standpoint, the changes in BMD in these HRA patients could not be explained by stem-neck angle or patient related factors.

  6. Large-diameter metal-on-metal total hip arthroplasties: a page in orthopedic history?

    Science.gov (United States)

    Singh, Gurpal; Meyer, Heiko; Ruetschi, Marcel; Chamaon, Kathrin; Feuerstein, Bernd; Lohmann, Christoph H

    2013-11-01

    Large-diameter metal-on-metal (MoM) bearings evolved from the success of hip resurfacing. These implants were used in revision surgery in cases with well-fixed acetabular cups but loose or failed femoral stems, to avoid cup revision. Early data showed low rates of dislocation and potentially low wear profiles due to better fluid film lubrication. The risk of impingement was also thought to be low due to the increased head-neck ratio. Subsequently large-diameter MoM heads gained popularity in primary hip replacement. Recent data has emerged on the unacceptably high revision rates among patients with large-diameter MoM total hip arthroplasties (THAs), high blood levels of metal ions, and adverse tissue reactions. The head-neck (cone-taper) modular interface probably represents the weak link in large metal heads that have been used on conventional tapers. Increased torque of the large head, micromotion, and instability at the cone-taper interface, synergistic interactions between corrosion and wear, edge loading, low clearance, and psoas impingement are the likely causes for early failure of these prostheses. Copyright © 2013 Wiley Periodicals, Inc.

  7. Current Insights Regarding Metal-on-Metal Bearings for Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Catherine Van Der Straeten

    2017-09-01

    Full Text Available Modern small diameter metal-on-metal (MoM bearings for total hip arthroplasty (THA have been developed in the nineteen-eighties to address the problem of polyethylene wear related osteolysis. Subsequently large diameter MoM hip resurfacings (HRA were designed for young and active patients to preserve bone and avoid dislocation. Large diameter MoM THA were originally meant as an easy femoral component-only revision solution for femoral neck fractures in HRA, but were then advocated for primary THA as well. In the last decade however, increasing numbers of revisions for adverse local tissues reactions (ALTR to metal debris have been reported. These ALTR are due to excessive wear of the MoM bearings, usually related to malpositioning of the components leading to edge loading, or in rare cases to metal sensitivity. Besides the immunological reactions, metal particles and ions have a potential local and systemic toxicity. Wear and tribocorrosion at the taper-trunnion connections of MoM THA but also THA with polyethylene and ceramic bearings have also been recognized as a cause of ALTR with extensive tissue destruction. Despite the fact that the long-term survivorship and functional results of certain MoM HRA are excellent and better than THA in the young and active patients group, MoM bearings have become very unpopular and are likely to be replaced by bearing couples of other materials.

  8. The natural history of inflammatory pseudotumors in asymptomatic patients after metal-on-metal hip arthroplasty.

    Science.gov (United States)

    Almousa, Sulaiman A; Greidanus, Nelson V; Masri, Bassam A; Duncan, Clive P; Garbuz, Donald S

    2013-12-01

    Although pseudotumors have been reported in 32% of asymptomatic metal-on-metal hips, the natural history of asymptomatic pseudotumors is unknown. The purpose of this study was to assess changes over time in asymptomatic pseudotumors and the effect of revision on pseudotumor mass. Followup ultrasound was performed a mean of 25.8 months (range, 21-31 months) after the detection of 15 pseudotumors and five isolated fluid collections in a cohort of 20 asymptomatic patients (13 metal-on-metal, three metal-on-polyethylene, and four hip resurfacings) [42]. Changes in pseudotumors and fluid collections size and nature, and serum ion levels were determined. Among the 15 nonrevised patients, pseudotumors increased in size in six (four solid and two cystic) of 10 patients, three of which had clinically important increases (13-148 cm(3); 28-74 cm(3); 47-104 cm(3)). Three pseudotumors (one solid and two cystic) disappeared completely (the largest measured 31 cm(3)). One solid pseudotumor decreased in size (24 to 18 cm(3)). In five revised patients, pseudotumors completely disappeared in four patients. The fifth patient had two masses that decreased from 437 cm(3) to 262 cm(3) and 43 cm(3) to 25 cm(3). All revision patients had a reduction of chromium (40.42 μ/L to 2.69 μ/L) and cobalt ions (54.19 μ/L to 0.64 μ/L). Of five isolated fluid collections, four completely disappeared (two metal-on-metal and two metal-on-polyethylene) and one (metal-on-metal) increased from 26 cm(3) to 136 cm(3). Our observations suggest pseudotumors frequently increase in size in asymptomatic patients with occasional remission of small masses. Revision resulted in remission of pseudotumors.

  9. Balancing innovation and medical device regulation: the case of modern metal-on-metal hip replacements

    Directory of Open Access Journals (Sweden)

    Howard JJ

    2016-08-01

    Full Text Available Jason J Howard1,2 1Division of Orthopedic Surgery, Department of Surgery, Sidra Medical and Research Center, 2Department of Orthopedic Surgery, Weill Cornell Medical College, Doha, Qatar Abstract: Due to problems with wear particle generation and subsequent loosening using conventional metal-on-polyethylene total hip replacements, there has been a shift toward alternative bearing systems, including metal-on-metal (MoM, for younger, more active patients with degenerative joint disease. Based on positive results from early short-term clinical studies, MoM hip replacements were readily adopted by orthopedic surgeons with thousands being implanted worldwide over the past decade. Unacceptably high revision rates reported by two national joint registries called into question the rigorousness of the regulatory approval process for these implants, particularly with respect to premarket data requirements to prove safety, effectiveness, and the appropriateness of the regulatory pathway chosen. The purpose of this review was to investigate the balance between facilitating the introduction of new medical technologies and the need to ensure safety and effectiveness through comprehensive regulatory assessment. The case of MoM hip replacement devices was used to frame the investigation and subsequent discussions. The regulatory approval processes and post-market surveillance requirements associated with three common MoM hip replacements (two resurfacings: the Birmingham and articular surface replacement and the articular surface replacement XL total hip replacement were investigated. With respect to modern MoM hip replacement devices, the balance between facilitating the introduction of these new medical technologies and the need to ensure safety and effectiveness through comprehensive regulatory assessment was not achieved. The lessons learned from these experiences have application beyond joint replacements to the introduction of new medical technologies in

  10. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... prosthesis. 888.3370 Section 888.3370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip) acetabular metal cemented prosthesis is a device intended to be implanted to replace a portion of the hip joint...

  11. 21 CFR 888.3360 - Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... uncemented prosthesis. 888.3360 Section 888.3360 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis is a device intended to be implanted...

  12. Metal on metal surface replacement of the hip. Experience of the McMinn prothesis.

    Science.gov (United States)

    McMinn, D; Treacy, R; Lin, K; Pynsent, P

    1996-08-01

    The historical failure of surface replacement has been due to the production of wear debris with subsequent bone resorption, loosening, and failure. To avoid these problems, a surface replacement using a metal on metal bearing allowing thin components and femoral design and instrumentation to avoid varus alignment has been designed. Two hundred thirty-five joints have been resurfaced with this prosthesis in almost 5 years. There have been no femoral neck fractures and no dislocations. There have been 4 designs differing in the method of fixation. In the press fit group, 6 of 70 hips had to be revised for aseptic loosening. In the cemented group, debonding of the cup occurred in 3 of 43 cases. Six patients had hydroxyapatite coated components and have had excellent clinical outcomes. The current design uses a peripherally expanded hydroxyapatite coated cup and a cemented metal head; 116 of this design have been implanted during a 19-month period with excellent outcome. Despite short followup the authors are hopeful that the combination of a polar metal on metal bearing with appropriate fixation will yield a method of preserving bone stock in the younger patient requiring arthroplasty.

  13. Metal ion concentrations in body fluids after implantation of hip replacements with metal-on-metal bearing--systematic review of clinical and epidemiological studies.

    Directory of Open Access Journals (Sweden)

    Albrecht Hartmann

    Full Text Available INTRODUCTION: The use of metal-on-metal (MoM total hip arthroplasty (THA increased in the last decades. A release of metal products (i.e. particles, ions, metallo-organic compounds in these implants may cause local and/or systemic adverse reactions. Metal ion concentrations in body fluids are surrogate measures of metal exposure. OBJECTIVE: To systematically summarize and critically appraise published studies concerning metal ion concentrations after MoM THA. METHODS: Systematic review of clinical trials (RCTs and epidemiological studies with assessment of metal ion levels (cobalt, chromium, titanium, nickel, molybdenum in body fluids after implantation of metalliferous hip replacements. Systematic search in PubMed and Embase in January 2012 supplemented by hand search. Standardized abstraction of pre- and postoperative metal ion concentrations stratified by type of bearing (primary explanatory factor, patient characteristics as well as study quality characteristics (secondary explanatory factors. RESULTS: Overall, 104 studies (11 RCTs, 93 epidemiological studies totaling 9.957 patients with measurement of metal ions in body fluids were identified and analyzed. Consistently, median metal ion concentrations were persistently elevated after implantation of MoM-bearings in all investigated mediums (whole blood, serum, plasma, erythrocytes, urine irrespective of patient characteristics and study characteristics. In several studies very high serum cobalt concentrations above 50 µg/L were measured (detection limit typically 0.3 µg/L. Highest metal ion concentrations were observed after treatment with stemmed large-head MoM-implants and hip resurfacing arthroplasty. DISCUSSION: Due to the risk of local and systemic accumulation of metallic products after treatment with MoM-bearing, risk and benefits should be carefully balanced preoperatively. The authors support a proposed "time out" for stemmed large-head MoM-THA and recommend a restricted

  14. Metal Ion Concentrations in Body Fluids after Implantation of Hip Replacements with Metal-on-Metal Bearing – Systematic Review of Clinical and Epidemiological Studies

    Science.gov (United States)

    Hartmann, Albrecht; Hannemann, Franziska; Lützner, Jörg; Seidler, Andreas; Drexler, Hans; Günther, Klaus-Peter; Schmitt, Jochen

    2013-01-01

    Introduction The use of metal-on-metal (MoM) total hip arthroplasty (THA) increased in the last decades. A release of metal products (i.e. particles, ions, metallo-organic compounds) in these implants may cause local and/or systemic adverse reactions. Metal ion concentrations in body fluids are surrogate measures of metal exposure. Objective To systematically summarize and critically appraise published studies concerning metal ion concentrations after MoM THA. Methods Systematic review of clinical trials (RCTs) and epidemiological studies with assessment of metal ion levels (cobalt, chromium, titanium, nickel, molybdenum) in body fluids after implantation of metalliferous hip replacements. Systematic search in PubMed and Embase in January 2012 supplemented by hand search. Standardized abstraction of pre- and postoperative metal ion concentrations stratified by type of bearing (primary explanatory factor), patient characteristics as well as study quality characteristics (secondary explanatory factors). Results Overall, 104 studies (11 RCTs, 93 epidemiological studies) totaling 9.957 patients with measurement of metal ions in body fluids were identified and analyzed. Consistently, median metal ion concentrations were persistently elevated after implantation of MoM-bearings in all investigated mediums (whole blood, serum, plasma, erythrocytes, urine) irrespective of patient characteristics and study characteristics. In several studies very high serum cobalt concentrations above 50 µg/L were measured (detection limit typically 0.3 µg/L). Highest metal ion concentrations were observed after treatment with stemmed large-head MoM-implants and hip resurfacing arthroplasty. Discussion Due to the risk of local and systemic accumulation of metallic products after treatment with MoM-bearing, risk and benefits should be carefully balanced preoperatively. The authors support a proposed „time out“ for stemmed large-head MoM-THA and recommend a restricted indication for hip

  15. [OBSERVATION OF EFFECTIVENESS OF HIP RESURFACING ARTHROPLASTY IN TREATMENT OF OSTEONECROSIS OF FEMORAL HEAD IN YOUNG AND MIDDLE-AGED PATIENTS].

    Science.gov (United States)

    Yu, Yinxian; Yi, Chengqing; Ma, Jinzhong; Wang, Qiugen

    2016-02-01

    To evaluate the clinical and radiographic outcomes of hip resurfacing arthroplasty (HRA) for treating osteonecrosis of the femoral head (ONFH) in young and middle-aged patients. Between January 2008 and April 2009, 34 patients with ONFH underwent HRA. There were 19 males and 15 females with an average age of 54 years (range, 33-59 years). Of 34 cases, 16 left hips and 18 right hips were involved, including 9 cases of alcohol-induced ONFH, 8 cases of steroid-induced ONFH, 7 cases of traumatic ONFH, and 10 cases of unexplained ONFH. According to modified Ficat classification system, 26 hips were rated as stage III, and 8 hips as stage IV. The Harris hip score (HHS) and modified University of California, Los Angeles (UCLA) activity score were used to evaluate the clinical results. Migration of prosthesis was assessed on the anteroposterior radiographs. The abduction angle was measured on the acetabular side. On the femoral side, varus-valgus shift was determined by measurement of stem-shaft angle. The axial collapse of femoral component was assessed with the component-lateral cortex ratio. Healing of incision by first intention was achieved in all patients without complications of infection and thrombosis of deep vein of lower extremities. Thirty-two patients were followed up 78 months on average (range, 70-84 months). No implant loosening, infection, femoral neck fracture, dislocation, and inflammatory pseudotumor were observed. At last follow-up, the HHS score was significantly increased to 95.22 +/- 1.47 from preoperative 50.10 +/- 2.27 (t=1.510, P=0.008). Modified UCLA activity score was significantly increased to 7.70 +/- 1.13 from preoperative 3.90 +/- 0.90 (t=0.830, P=0.003). The abduction angle, stem-shaft angle, and compotent-lateral cortex ratio showed no significant difference between at 3 days after operation and last follow-up (P>0.05). If the indication of operation is mastered strictly, HRA may be effective in treatment for ONFH at Ficat stage III or IV

  16. 21 CFR 888.3380 - Hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... metal/polyacetal cemented prosthesis. 888.3380 Section 888.3380 Food and Drugs FOOD AND DRUG... Devices § 888.3380 Hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis is a two...

  17. Comparison of Patient-Reported Outcome from Neck-Preserving, Short-Stem Arthroplasty and Resurfacing Arthroplasty in Younger Osteoarthritis Patients

    Directory of Open Access Journals (Sweden)

    Marius Dettmer

    2015-01-01

    Full Text Available Hip resurfacing has been considered a good treatment option for younger, active osteoarthritis patients. However, there are several identified issues concerning risk for neck fractures and issues related to current metal-on-metal implant designs. Neck-preserving short-stem implants have been discussed as a potential alternative, but it is yet unclear which method is better suited for younger adults. We compared hip disability and osteoarthritis outcome scores (HOOS from a young group of patients (n=52, age 48.9 ± 6.1 years who had received hip resurfacing (HR with a cohort of patients (n=73, age 48.2 ± 6.6 years who had received neck-preserving, short-stem implant total hip arthroplasty (THA. Additionally, durations for both types of surgery were compared. HOOS improved significantly preoperatively to last followup (>1 year in both groups (p<0.0001, η2=0.69; there were no group effects or interactions. Surgery duration was significantly longer for resurfacing (104.4 min ± 17.8 than MiniHip surgery (62.5 min ± 14.8, U=85.0, p<0.0001, η2=0.56. The neck-preserving short-stem approach may be preferable to resurfacing due to the less challenging surgery, similar outcome, and controversy regarding resurfacing implant designs.

  18. Validation of the femoral component placement during hip resurfacing: a comparison between the conventional jig, patient-specific template, and CT-based navigation.

    Science.gov (United States)

    Kitada, Makoto; Sakai, Takashi; Murase, Tsuyoshi; Hanada, Toshihisa; Nakamura, Nobuo; Sugano, Nobuhiko

    2013-06-01

    Appropriate insertion of a femoral guidewire is essential for hip resurfacing. A simulation study was planned using synthetic femoral bone models and the accuracy and precision of femoral guidewire alignment and insertion point were compared between conventional jigs, patient-specific templates, and computed tomography (CT) based navigation techniques. Anteversion, stem-shaft angle, and the three-dimensional insertion point were measured postoperative with CT. Errors between planned and postoperative measurement and precision were evaluated. There were no statistically significant differences in error for anteversion or insertion point, although the mechanical jig showed greater error in the stem-shaft angle than the others. Patient-specific template and CT-based navigation showed good precision with high intraclass correlation (ICC) (template, 0.908 to 1.000; navigation, 0.929 to 0.995) and small root mean square error (RMSE) (0.954 to 2.969; 1.468 to 3.213). The mechanical jig group performance was inferior to the others. Patient-specific templates and CT-based navigation had good accuracy and precision. The mechanical jig technique was inferior to the others. Copyright © 2013 John Wiley & Sons, Ltd.

  19. Heavy reading in heavy metal : Unraveling the mystery of hip tissue in metal on metal total hip arthroplasty

    NARCIS (Netherlands)

    Boomsma, M.F.

    2017-01-01

    In this thesis, we investigated the use of computer tomography (CT) for the screening of patients with a metal-on-metal (MoM) hip prosthesis in two patient cohorts. With a self-established CT grading scale, we have shown that CT is a reliable method for the diagnosis of postoperative pathological

  20. Self-reported neurological clinical manifestations of metal toxicity in metal-on-metal hip arthroplasty

    NARCIS (Netherlands)

    van Lingen, Christiaan P.; Ettema, Harmen B.; Van Der Straeten, Catherine; Kollen, Bouwdewijn J.; Verheyen, Cees C. P. M.

    2014-01-01

    Adverse reactions to metal particle debris have been increasingly reported as a complication following large head metal-on-metal (MoM) hip arthroplasty. Elevated metal ion levels are a cause for concern. The aim of this study is to evaluate whether exposure to cobalt is associated with patient

  1. 21 CFR 888.3390 - Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... cemented or uncemented prosthesis. 888.3390 Section 888.3390 Food and Drugs FOOD AND DRUG ADMINISTRATION... § 888.3390 Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis is a two-part...

  2. Resurfacing Graphics

    Directory of Open Access Journals (Sweden)

    Prof. Patty K. Wongpakdee

    2013-06-01

    Full Text Available “Resurfacing Graphics” deals with the subject of unconventional design, with the purpose of engaging the viewer to experience the graphics beyond paper’s passive surface. Unconventional designs serve to reinvigorate people, whose senses are dulled by the typical, printed graphics, which bombard them each day. Today’s cutting-edge designers, illustrators and artists utilize graphics in a unique manner that allows for tactile interaction. Such works serve as valuable teaching models and encourage students to do the following: 1 investigate the trans-disciplines of art and technology; 2 appreciate that this approach can have a positive effect on the environment; 3 examine and research other approaches of design communications and 4 utilize new mediums to stretch the boundaries of artistic endeavor. This paper examines how visuals communicators are “Resurfacing Graphics” by using atypical surfaces and materials such as textile, wood, ceramics and even water. Such non-traditional transmissions of visual language serve to demonstrate student’s overreliance on paper as an outdated medium. With this exposure, students can become forward-thinking, eco-friendly, creative leaders by expanding their creative breadth and continuing the perpetual exploration for new ways to make their mark.

  3. Resurfacing Graphics

    Directory of Open Access Journals (Sweden)

    Prof. Patty K. Wongpakdee

    2013-06-01

    Full Text Available “Resurfacing Graphics” deals with the subject of unconventional design, with the purpose of engaging the viewer to experience the graphics beyond paper’s passive surface. Unconventional designs serve to reinvigorate people, whose senses are dulled by the typical, printed graphics, which bombard them each day. Today’s cutting-edge designers, illustrators and artists utilize graphics in a unique manner that allows for tactile interaction. Such works serve as valuable teaching models and encourage students to do the following: 1 investigate the trans-disciplines of art and technology; 2 appreciate that this approach can have a positive effect on the environment; 3 examine and research other approaches of design communications and 4 utilize new mediums to stretch the boundaries of artistic endeavor. This paper examines how visuals communicators are “Resurfacing Graphics” by using atypical surfaces and materials such as textile, wood, ceramics and even water. Such non-traditional transmissions of visual language serve to demonstrate student’s overreliance on paper as an outdated medium. With this exposure, students can become forward-thinking, eco-friendly, creative leaders by expanding their creative breadth and continuing the perpetual exploration for new ways to make their mark. 

  4. Pre-clinical evaluation of ceramic femoral head resurfacing prostheses using computational models and mechanical testing.

    Science.gov (United States)

    Dickinson, A S; Browne, M; Wilson, K C; Leffers, J R T; Taylor, A C

    2011-09-01

    Ceramic-on-ceramic hip resurfacing can potentially offer the bone-conserving advantages of resurfacing while eliminating metal ion release. Thin-walled ceramic resurfacing heads are conceivable following developments in the strength and reliability of ceramic materials, but verification of new designs is required. The present study aimed to develop a mechanical pre-clinical analysis verification process for ceramic resurfacing heads, using the DeltaSurf prosthesis design as a case study. Finite element analysis of a range of in vivo scenarios was used to design a series of physiologically representative mechanical tests, which were conducted to verify the strength of the prosthesis. Tests were designed to simulate ideal and worst-case in vivo loading and support, or to allow comparison with a clinically successful metallic device. In tests simulating ideal loading and support, the prosthesis sustained a minimum load of 39 kN before fracture, and survived 10 000 000 fatigue cycles of 0.534 kN to 5.34 kN. In worst-case tests representing a complete lack of superior femoral head bone support or pure cantilever loading of the prosthesis stem, the design demonstrated strength comparable to that of the equivalent metal device. The developed mechanical verification test programme represents an improvement in the state of the art where international test standards refer largely to total hip replacement prostheses. The case study's novel prosthesis design performed with considerable safety margins compared with extreme in vivo loads, providing evidence that the proposed ceramic resurfacing heads should have sufficient strength to perform safely in vivo. Similar verification tests should be designed and conducted for novel ceramic prosthesis designs in the future, leading the way to clinical evaluation.

  5. Blood metal ion concentrations in metal-on-metal total hip arthroplasty.

    Science.gov (United States)

    Ohtsuru, Tadahiko; Morita, Yuji; Murata, Yasuaki; Shimamoto, Shuji; Munakata, Yutaro; Kato, Yoshiharu

    2017-05-01

    The hip placement with a metal-on-metal (MOM) bearing has been used for both surface replacement and total hip arthroplasty (THA). Use of MOM bearing for hip replacement reduces the wear compared to conventional bearings. We prospectively assessed 30 patients who underwent unilateral MOM THA. A control group of 30 patients who underwent metal-on-polyethylene THA using the implants as the other group, except for bearing, were accessed. Blood samples were collected preoperatively and at 3- , 6- , 9- , 12- , 15- , 18- , and 24-month intervals. Changes in mean blood metal ion concentration were compared between the MOM and metal-on-polyethylene groups. A statistically significant positive correlation was observed between blood cobalt and chromium concentrations in all of the patients. The mean blood ion concentrations of the MOM were significantly higher than those of the metal-on-polyethylene. A statistically significant negative correlation was found between maximum blood cobalt concentration and cup version angle. The maximum blood chromium concentrations in the patients who had larger cup version angles were more likely to decrease. We considered that cup version angle is one of the factors that have the greatest effect on blood metal ion concentration, and the target cup version angle that did not induce an increase in blood metal ion concentrations was approximately 20°.

  6. Large head metal-on-metal cementless total hip arthroplasty versus 28mm metal-on-polyethylene cementless total hip arthroplasty: design of a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    van Raaij Jos JAM

    2008-10-01

    Full Text Available Abstract Background Osteoarthritis of the hip is successfully treated by total hip arthroplasty with metal-on-polyethylene articulation. Polyethylene wear debris can however lead to osteolysis, aseptic loosening and failure of the implant. Large head metal-on-metal total hip arthroplasty may overcome polyethylene wear induced prosthetic failure, but can increase systemic cobalt and chromium ion concentrations. The objective of this study is to compare two cementless total hip arthroplasties: a conventional 28 mm metal-on-polyethylene articulation and a large head metal-on-metal articulation. We hypothesize that the latter arthroplasties show less bone density loss and higher serum metal ion concentrations. We expect equal functional scores, greater range of motion, fewer dislocations, fewer periprosthetic radiolucencies and increased prosthetic survival with the metal-on-metal articulation. Methods A randomized controlled trial will be conducted. Patients to be included suffer from non-inflammatory degenerative joint disease of the hip, are aged between 18 and 80 and are admitted for primary cementless unilateral total hip arthroplasty. Patients in the metal-on-metal group will receive a cementless titanium alloy acetabular component with a cobalt-chromium liner and a cobalt-chromium femoral head varying from 38 to 60 mm. Patients in the metal-on-polyethylene group will receive a cementless titanium alloy acetabular component with a polyethylene liner and a 28 mm cobalt-chromium femoral head. We will assess acetabular bone mineral density by dual energy x-ray absorptiometry (DEXA, serum ion concentrations of cobalt, chromium and titanium, self reported functional status (Oxford hip score, physician reported functional status and range of motion (Harris hip score, number of dislocations and prosthetic survival. Measurements will take place preoperatively, perioperatively, and postoperatively (6 weeks, 1 year, 5 years and 10 years. Discussion

  7. Increased Mortality in Metal-on-Metal versus Non-Metal-on-Metal Primary Total Hip Arthroplasty at 10 Years and Longer Follow-Up: A Systematic Review and Meta-Analysis.

    Directory of Open Access Journals (Sweden)

    B G Pijls

    Full Text Available There are concerns about increased mortality in patients with metal-on-metal bearings in total hip arthroplasty (THA.To determine the mortality and the morbidity in patients with metal-on-metal articulations (MOM THA compared to patients with non-metal-on-metal articulations (non-MOM THA after primary total hip arthroplasty.Search of PubMed, MEDLINE, EMBASE, Web of Science, Cochrane, CINAHL, AcademicSearchPremier, ScienceDirect, Wiley and clinical trial registers through March 2015, augmented by a hand search of references from the included articles. No language restrictions were applied.Two reviewers screened and identified randomised controlled trials and observational studies of primary total hip arthroplasty comparing MOM THA with non-MOM THA.Two reviewers independently extracted study data and assessed risk of bias. Risk differences (RD were calculated with random effect models. Meta-regression was used to explore modifying factors.Difference in mortality and difference in morbidity expressed as revisions and medical complications between patients with MOM THA and non-MOM THA.Forty-seven studies were included, comprising 4,000 THA in randomised trials and over 500,000 THA in observational studies. For mortality, random effects analysis revealed a higher pooled RD of 0.7%, 95%, confidence interval (CI [0.0%, 2.3%], I-square 42%; the heterogeneity was explained by differences in follow-up. When restricted to studies with long term follow-up (i.e. 10 years or more, the RD for mortality was 8.5%, 95%, CI [5.8%, 11.2%]; number needed to treat was 12. Further subgroup analyses and meta-regression random effects models revealed no evidence for other moderator variables (study level covariates, e.g. resurfacing vs. non-resurfacing MOM than follow-up duration. The quality of the evidence presented in this meta-analysis was characterized as moderate according to the CLEAR-NPT (for non-pharmacological trials and Cochrane risk of bias Table

  8. [Detection of metal ions in hair after metal-metal hip arthroplasty].

    Science.gov (United States)

    Hernandez-Vaquero, D; Rodríguez de la Flor, M; Fernandez-Carreira, J M; Sariego-Muñiz, C

    2014-01-01

    There is an increase in the levels of metals in the serum and urine after the implantation of some models of metal-metal hip prosthesis. It has recently been demonstrated that there is an association between these levels and the levels found in hair. The aim of this study is to determine the presence of metals in hair, and to find out whether these change over time or with the removal of the implant. The levels of chromium, cobalt and molybdenum were determined in the hair of 45 patients at 3, 4, 5, and 6 years after a hip surface replacement. The mean age was 57.5 years, and two were female. Further surgery was required to remove the replacement and implant a new model with metal-polyethylene friction in 11 patients, 5 of them due to metallosis and a periarticular cyst. The mean levels of metals in hair were chromium 163.27 ppm, cobalt 61.98 ppm, and molybdenum 31.36 ppm, much higher than the levels found in the general population. A decrease in the levels of chromium (43.8%), molybdenum (51.1%), and cobalt (91.1%) was observed at one year in the patients who had further surgery to remove the prosthesis. High concentrations of metals in the hair are observed in hip replacements with metal-metal friction, which decrease when that implant is removed. The determination of metal ions in hair could be a good marker of the metal poisoning that occurs in these arthroplasty models. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.

  9. Cardiac transplant due to metal toxicity associated with hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Sheldon Moniz, MBBS (UWA

    2017-09-01

    Full Text Available Concerns regarding metal-on-metal (MoM bearing couples in total hip arthroplasty are well documented in the literature with cobalt (Co and chromium (Cr toxicity causing a range of both local and systemic adverse reactions. We describe the case of a patient undergoing cardiac transplantation as a direct result of Co and Cr toxicity following a MoM hip replacement. Poor implant positioning led to catastrophic wear generating abundant wear particles leading to Co and Cr toxicity, metallosis, bony destruction, elevated metal ion levels, and adverse biological responses. Systemic symptoms continued for 3 years following cardiac transplantation with resolution only after revision hip arthroplasty. There was no realization in the initial cardiac assessment and subsequent transplant workup that the hip replacement was the likely cause of the cardiac failure, and the hip replacement was not recognized as the cause until years after the heart transplant. This case highlights the need for clinicians to be aware of systemic MoM complications as well as the importance of positioning when using these prostheses.

  10. The effect of the metal-on-metal hip controversy on internet search activity.

    LENUS (Irish Health Repository)

    Phelan, Nigel

    2014-01-04

    The recall of the articular surface replacement (ASR) hip prosthesis in 2010 represents one of the most controversial areas in orthopaedic surgery in recent years. The aim of this study was to compare the impact of the metal-on-metal hip controversy on Internet search activity in four different regions and determine whether the number of related news reports affected Internet search activity. The Google Trends, Keywords and News applications were used to record the number of news articles and Internet search activity for the terms "hip recall", "metal-on-metal hip" and "ASR hip" from October 2009 to October 2012 in the USA, the UK, Australia and Ireland. There was a large increase in search activity following the official recall in August 2010 in all countries. There was significantly greater search activity after the recall in Ireland compared with the UK for the search term "hip recall" (P = 0.004). For the term "metal-on-metal hip", the UK had significantly more search activity (P = 0.0009). There was a positive correlation between the number of news stories in UK and Ireland with Internet search activity but not in the USA or Australia. Differences between countries affected by the same recall highlight the complex effects of the media on public awareness. The data demonstrates a window of opportunity prior to the official recall for the development of an awareness campaign to provide patients with accurate information.

  11. The association between metal allergy, total hip arthroplasty, and revision

    DEFF Research Database (Denmark)

    Thyssen, Jacob Pontoppidan; Jakobsen, Stig Storgaard; Engkilde, Kåre

    2009-01-01

    BACKGROUND AND PURPOSE: It has been speculated that the prevalence of metal allergy may be higher in patients with implant failure. We compared the prevalence and cause of revisions following total hip arthroplasty (THA) in dermatitis patients suspected to have contact allergy and in patients in ...

  12. Focal femoral condyle resurfacing.

    LENUS (Irish Health Repository)

    Brennan, S A

    2013-03-01

    Focal femoral inlay resurfacing has been developed for the treatment of full-thickness chondral defects of the knee. This technique involves implanting a defect-sized metallic or ceramic cap that is anchored to the subchondral bone through a screw or pin. The use of these experimental caps has been advocated in middle-aged patients who have failed non-operative methods or biological repair techniques and are deemed unsuitable for conventional arthroplasty because of their age. This paper outlines the implant design, surgical technique and biomechanical principles underlying their use. Outcomes following implantation in both animal and human studies are also reviewed. Cite this article: Bone Joint J 2013;95-B:301-4.

  13. INCIDENTALOMA FOUND IN A METAL-ON-METAL REVISION TOTAL HIP ARTHROPLASTY: A CASE REPORT.

    Directory of Open Access Journals (Sweden)

    Gabriele Falzarano

    2014-04-01

    Full Text Available Metal-on-metal coupling in total hip replacements has traditionally been a valid alternative to other total hip bearings for young adults and very active elderly patients. Unfortunately, clinical experience has revealed that the difference in strength between the titanium alloy stem and the cobalt alloy-bearing surface leads to a conflict between the acetabular component and the head, which inturn leads to abnormal wear and osteolysis. The major problems are osteolysis, metal ion intoxication, potential genome toxicity, neoplasms, allergies and implant failure. The authors present an incidental finding of a pseudotumour of the external rotators of the hip in a total hip replacement (THR revision in a 68 year old female patient.

  14. The Management of the Symptomatic Patient With a Metal-on-Metal Hip Prosthesis.

    Science.gov (United States)

    Harrington, Kate; Phelan, Emma; Torreggiani, William C; Doody, Orla

    2016-02-01

    Metal-on-metal (MoM) hip implants have gained popularity due to their greater stability and reduction in implant failure compare to metal-on-polyethylene prostheses. However, as well as carrying general risks of hip implantation, risks specifically associated with MoM implants have been well documented in recent years. Conditions such as pseudotumours or aseptic lymphocyte-dominated vasculitis-associated lesions are specific to MoM hip implants. In this review we discuss the typical patient presentation, the investigations that should be performed, the typical findings on various imaging modalities, and the treatment options of symptomatic patients with MoM hip arthroplasties. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  15. 21 CFR 888.3358 - Hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... porous-coated uncemented prosthesis. 888.3358 Section 888.3358 Food and Drugs FOOD AND DRUG... Devices § 888.3358 Hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis. (a) Identification. A hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis is a device...

  16. High performance sinter-HIP for hard metals

    International Nuclear Information System (INIS)

    Hongxia Chen; Deming Zhang; Yang Li; Jingping Chen

    2001-01-01

    The horizontal sinter-HIP equipment with great charge capacity and high performance, developed and manufactured by Central Iron and Steel Research Institute(CISRI), is mainly used for sintering and condensation of hard metals. This equipment is characterized by large hot zone, high heating speed, good temperature uniformity and fast cooling system. The equipment can provide uniform hot zone with temperature difference less than 6 o C at 1500-1600 o C and 6-10 MPa by controlling temperature, pressure and circulation of gas precisely. Using large scale horizontal sinter-HIP equipment to produce hard matals have many advantages such as stable quality, high efficiency of production, high rate of finished products and low production cost, so this equipment is a good choice for manufacturer of hard metals. (author)

  17. Complications Related to Metal-on-Metal Articulation in Trapeziometacarpal Joint Total Joint Arthroplasty

    DEFF Research Database (Denmark)

    Frølich, Christina; Hansen, Torben Bæk

    2015-01-01

    Adverse reactions to metal-on-metal (MoM) prostheses are well known from total hip joint resurfacing arthroplasty with elevated serum chrome or cobalt, pain and pseudo tumor formation. It may, however, also be seen after total joint replacement of the trapeziometacarpal joint using MoM articulation...

  18. High Re-Operation Rates Using Conserve Metal-On-Metal Total Hip Articulations

    DEFF Research Database (Denmark)

    Mogensen, S L; Jakobsen, Thomas; Christoffersen, Hardy

    2016-01-01

    INTRODUCTION: Metal-on-metal hip articulations have been intensely debated after reports of adverse reactions and high failure rates. The aim of this study was to retrospectively evaluate the implant of a metal-on.metal total hip articulation (MOM THA) from a single manufacture in a two...... of 53 months. 4 pseudotumors were diagnosed at time of follow up but no substantiated link was made between adverse reactions and re-operations. CONCLUSION: The high re-operation rates found in this study raised concern about the usage of the MOM THA and subsequently lead to the termination......-center study. MATERIALS AND METHODS: 108 CONSERVE(®) MOM THA were implanted in 92 patients between November 2005 and December 2010. Patients had at time of retrospective evaluation their journals reviewed for re-operations and adverse reactions. RESULTS: 20 hips were re-operated (18.4%) at a mean follow up...

  19. [Survey on the use and behaviour of metal-metal hip replacements in Spain].

    Science.gov (United States)

    Calcerrada, N; Fernández-Vega, A; Valls-León, C; Garcia-Cimbrelo, E

    2016-01-01

    Following medical device alerts published in different countries of problems with metal-on-metal total hip replacements, the Spanish Agency of Medicines and Medical Devices (AEMPS) in collaboration with the Spanish Hip Society Surgery designed a national survey to gather information on the use and behaviour of these hip implants. The survey consisted of a questionnaire sent by e-mail to 283 clinical centre recipients of metal-on-metal hips to be filled in by surgeons with expertise in the field. A total of 257 questionnaires were completed. The response rate of the clinical centres was 36.7%. A total of 97.7% of the responses reported that clinical and radiological follow-ups are carried out, and 79.6% undertook metal ion analyses (chromium and cobalt). A large majority (83.6%) of the responders who had who used surface implants, and 70% of those with large-head implants reported peri-operative complications. The most common complication was pain (25% with surface implants and 30.8% with large-head implants). Currently 80.8% of those responding were considering abandoning implanting of these hip replacements. Despite the many limitations to this study, the survey has allowed us to obtain in a quick first view of the implant scenario of Metal on Metal hip implants in Spain, and to determine the type of patient implanted, the time of implantation, and the experience/expertise of the surgeons, and the type of follow-up carried out. Copyright © 2015 SECOT. Published by Elsevier Espana. All rights reserved.

  20. Fatal Cobalt Toxicity after a Non-Metal-on-Metal Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Rinne M. Peters

    2017-01-01

    Full Text Available This case illustrates the potential for systemic cobalt toxicity in non-metal-on-metal bearings and its potentially devastating consequences. We present a 71-year-old male with grinding sensations in his right hip following ceramic-on-ceramic total hip arthroplasty (THA. After diagnosing a fractured ceramic liner, the hip prosthesis was revised into a metal-on-polyethylene bearing. At one year postoperatively, X-rays and MARS-MRI showed a fixed reversed hybrid THA, with periarticular densities, flattening of the femoral head component, and a pattern of periarticular metal wear debris and pseudotumor formation. Before revision could take place, the patient was admitted with the clinical picture of systemic cobalt toxicity, supported by excessively high serum cobalt and chromium levels, and ultimately died. At autopsy dilated cardiomyopathy as cause of death was hypothesized. A third body wear reaction between ceramic remnants and the metal femoral head very likely led to excessive metal wear, which contributed systemic cobalt toxicity leading to neurotoxicity and heart failure. This case emphasizes that fractured ceramic-on-ceramic bearings should be revised to ceramic-on-ceramic or ceramic-on-polyethylene bearings, but not to metal-on-polyethylene bearings. We aim to increase awareness among orthopedic surgeons for clinical clues for systemic cobalt intoxication, even when there is no metal-on-metal bearing surface.

  1. MRI of early symptomatic metal-on-metal total hip arthroplasty: a retrospective review of radiological findings in 20 hips

    International Nuclear Information System (INIS)

    Toms, A.P.; Marshall, T.J.; Cahir, J.; Darrah, C.; Nolan, J.; Donell, S.T.; Barker, T.; Tucker, J.K.

    2008-01-01

    Aim: To perform a retrospective review of all the conventional radiographic and magnetic resonance imaging (MRI) studies performed in patients with early postoperative pain following cobalt-chrome metal-on-metal total hip arthroplasty. Methods: A retrospective review of the radiology, surgical findings and histology in nineteen patients who had undergone a total of 20 hip arthroplasties using a cobalt-chromium on cobalt-chromium alloy prosthesis was undertaken. Results: Measures of implant placement on the immediate postoperative radiographs were all within the normal ranges (n = 20). Where more than one postoperative radiograph was available statistical analysis revealed no evidence of progressive change before the MRI examination (14). The median postoperative time to MRI was 35 months (range 11-63 months). Abnormalities were demonstrated using MRI in all symptomatic hips (n = 20). These comprised: periprosthetic fluid collections (20), which were isointense to muscle on T1-weighted images in 19 cases and hyperintense on T2-weighted images in 18 cases, periprosthetic bone marrow oedema (n = 6), muscle oedema (n = 4), avulsion of the gluteus minimus and medius tendons (n = 5), atrophy of piriformis (n = 15) and obturator internus (n = 17), and fracture of the medial calcar (n = 1). Operative findings in patients who had undergone revision surgery (n = 15) included: fluid-filled cavities (n = 11), soft tissue necrosis (n = 8), gluteal tendon avulsion (n = 5), proximal femoral diaphyseal necrosis (n = 4), and pitting and corrosion of the femoral stems (n = 8), which were, in all cases, firmly fixed to the cement mantle. Histology revealed viable tissue in six hips with necrosis (n = 12) and fibrin deposition (n = 15) being the predominate findings. Other findings included a perivascular lymphocytic infiltrate (n = 5), features of active inflammation (n = 4), and metallosis (n = 1). Conclusion: A significant number of patients with metal-on-metal hip replacements

  2. MRI of early symptomatic metal-on-metal total hip arthroplasty: a retrospective review of radiological findings in 20 hips

    Energy Technology Data Exchange (ETDEWEB)

    Toms, A.P. [Department of Radiology, Norfolk and Norwich University Hospital, Norwich, Norfolk (United Kingdom)], E-mail: andoni.toms@nnuh.nhs.uk; Marshall, T.J.; Cahir, J. [Department of Radiology, Norfolk and Norwich University Hospital, Norwich, Norfolk (United Kingdom); Darrah, C.; Nolan, J. [Department of Orthopaedics, Norfolk and Norwich University Hospital, Norwich, Norfolk (United Kingdom); Donell, S.T. [Institute of Health, University of East Anglia, Norwich, Norfolk (United Kingdom); Barker, T. [Department of Pathology, Norfolk and Norwich University Hospital, Norwich, Norfolk (United Kingdom); Tucker, J.K. [Department of Orthopaedics, Norfolk and Norwich University Hospital, Norwich, Norfolk (United Kingdom)

    2008-01-15

    Aim: To perform a retrospective review of all the conventional radiographic and magnetic resonance imaging (MRI) studies performed in patients with early postoperative pain following cobalt-chrome metal-on-metal total hip arthroplasty. Methods: A retrospective review of the radiology, surgical findings and histology in nineteen patients who had undergone a total of 20 hip arthroplasties using a cobalt-chromium on cobalt-chromium alloy prosthesis was undertaken. Results: Measures of implant placement on the immediate postoperative radiographs were all within the normal ranges (n = 20). Where more than one postoperative radiograph was available statistical analysis revealed no evidence of progressive change before the MRI examination (14). The median postoperative time to MRI was 35 months (range 11-63 months). Abnormalities were demonstrated using MRI in all symptomatic hips (n = 20). These comprised: periprosthetic fluid collections (20), which were isointense to muscle on T1-weighted images in 19 cases and hyperintense on T2-weighted images in 18 cases, periprosthetic bone marrow oedema (n = 6), muscle oedema (n = 4), avulsion of the gluteus minimus and medius tendons (n = 5), atrophy of piriformis (n = 15) and obturator internus (n = 17), and fracture of the medial calcar (n = 1). Operative findings in patients who had undergone revision surgery (n = 15) included: fluid-filled cavities (n = 11), soft tissue necrosis (n = 8), gluteal tendon avulsion (n = 5), proximal femoral diaphyseal necrosis (n = 4), and pitting and corrosion of the femoral stems (n = 8), which were, in all cases, firmly fixed to the cement mantle. Histology revealed viable tissue in six hips with necrosis (n = 12) and fibrin deposition (n = 15) being the predominate findings. Other findings included a perivascular lymphocytic infiltrate (n = 5), features of active inflammation (n = 4), and metallosis (n = 1). Conclusion: A significant number of patients with metal-on-metal hip replacements

  3. Early results of metal on metal articulation total hip arthroplasty in young patients.

    Science.gov (United States)

    Mohamad, J A; Kwan, M K; Merican, A M; Abbas, A A; Kamari, Z H; Hisa, M K; Ismail, Z; Idrus, R M

    2004-12-01

    We report our early experience of 20 cases of metal on metal articulation total hip arthroplasty in 19 young patients. Avascular necrosis of the femoral head (63%) was the commonest diagnosis for patients undergoing this procedure, followed by osteoarthritis (21%). In general, most of the patients were young and physically active with an average age of 43.1 years (range, 25 to 58 years). The average follow-up period was 18 months (range, 7 to 46 months). The mean total Harris Hip Score preoperatively and at final follow-up was 31 points and 89 points respectively. The mean total Pain Score improved from an average of 11.5 to 41.1 points at final follow-up. Sixteen (84%) of the patients had a good to excellent hip score. There was one dislocation, which stabilized after reduction and conservative management. One case of early infection underwent a two-staged revision.

  4. USING TRABECULAR METAL AUGMENTS FOR TOTAL HIP REPLACEMENT IN PATIENTS AFTER ACETABULAR FRACTURES

    Directory of Open Access Journals (Sweden)

    R. M. Tikhilov

    2011-01-01

    Full Text Available The authors presented the experience of treatment of two patients with hip arthritis after acetabular fracture. Both patients were treated with total hip replacement. During the operation, to manage posterior-superior bone defects of the acetabulum, augments of trabecular metal were used. Pain and limitation of motions in hip were indications for operative treatment. After a year of follow up there was no pain in hip; also recovery of motion and improved quality of life were observed.

  5. Albumin as marker for susceptibility to metal ions in metal-on-metal hip prosthesis patients.

    Science.gov (United States)

    Facchin, F; Catalani, S; Bianconi, E; Pasquale, D De; Stea, S; Toni, A; Canaider, S; Beraudi, A

    2017-04-01

    Metal-on-metal (MoM) hip prostheses are known to release chromium and cobalt (Co), which negatively affect the health status, leading to prosthesis explant. Albumin (ALB) is the main serum protein-binding divalent transition metals. Its binding capacity can be affected by gene mutations or modification of the protein N-terminal region, giving the ischaemia-modified albumin (IMA). This study evaluated ALB, at gene and protein level, as marker of individual susceptibility to Co in MoM patients, to understand whether it could be responsible for the different management of this ion. Co was measured in whole blood, serum and urine of 40 MoM patients. A mutational screening of ALB was performed to detect links between mutations and metal binding. Finally, serum concentration of total ALB and IMA were measured. Serum total ALB concentration was in the normal range for all patients. None of the subjects presented mutations in the investigated gene. Whole blood, serum and urine Co did not correlate with serum total ALB or IMA, although IMA was above the normal limit in most subjects. The individual susceptibility is very important for patients' health status. Despite the limited results of this study, we provide indications on possible future investigations on the toxicological response to Co.

  6. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Science.gov (United States)

    2010-04-01

    ... uncemented acetabular component, prosthesis. 888.3330 Section 888.3330 Food and Drugs FOOD AND DRUG..., prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis is a two-part device intended to be implanted to replace a hip joint. The device...

  7. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Science.gov (United States)

    2010-04-01

    ... cemented acetabular component, prosthesis. 888.3320 Section 888.3320 Food and Drugs FOOD AND DRUG..., prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis is a two-part device intended to be implanted to replace a hip joint. The device...

  8. Poor Acetabular Component Orientation Increases Revision Risk in Metal-on-Metal Hip Arthroplasty.

    Science.gov (United States)

    Tauriainen, Tuomas J T; Niinimäki, Tuukka T; Niinimäki, Jaakko L; Nousiainen, Tomi O P; Leppilahti, Juhana I

    2017-07-01

    The rate of and the reasons for the failure of metal-on-metal (MoM) bearings have recently been discussed in literature. The aim of this study was to evaluate the influence of acetabular cup inclination and version angles on revision risk in patients with MoM hip arthroplasty. We retrospectively reviewed 825 patients (976 hips) who underwent a MoM hip arthroplasty between 2000 and 2013. There were 474 men and 351 women, with a mean age of 58 (19-86) years. Acceptable cup orientation was considered to be inside the Lewinnek's safe zone. The mean acetabular inclination angle was 48.9° (standard deviation, 8.1°; range, 16°-76°) and version angle 20.6° (standard deviation, 9.9°; range, -25 to 46°). The cup was found to be outside the Lewinnek's safe zone in 571 hips (58.5%). Acetabular cup revision surgery was performed in 157 hips (16.1%). The cup angles were outside Lewinnek's safe zone in 69.2% of the revised hips. The mean interobserver reliability and intraobserver repeatability of the measurements of cup inclination and version angles were excellent (intraclass correlation coefficients >0.90). The odds ratio for revision in hips outside vs inside the Lewinnek's safe zone was 1.82 (95% confidence interval, 1.26-2.62; P = .0014). Our findings provide compelling evidence that a cup position outside the Lewinnek's safe zone is associated with increased revision risk in patients with MoM arthroplasty. Copyright © 2017. Published by Elsevier Inc.

  9. 21 CFR 888.3310 - Hip joint metal/polymer constrained cemented or uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... uncemented prosthesis. 888.3310 Section 888.3310 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Hip joint metal/polymer constrained cemented or uncemented prosthesis. (a) Identification. A hip joint metal/polymer constrained cemented or uncemented prosthesis is a device intended to be implanted to...

  10. 21 CFR 888.3340 - Hip joint metal/composite semi-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... cemented prosthesis. 888.3340 Section 888.3340 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Hip joint metal/composite semi-constrained cemented prosthesis. (a) Identification. A hip joint metal/composite semi-constrained cemented prosthesis is a two-part device intended to be implanted to replace a...

  11. 21 CFR 888.3350 - Hip joint metal/polymer semi-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... prosthesis. 888.3350 Section 888.3350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... metal/polymer semi-constrained cemented prosthesis. (a) Identification. A hip joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a hip joint. The device limits...

  12. 21 CFR 888.3300 - Hip joint metal constrained cemented or uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... prosthesis. 888.3300 Section 888.3300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... metal constrained cemented or uncemented prosthesis. (a) Identification. A hip joint metal constrained cemented or uncemented prosthesis is a device intended to be implanted to replace a hip joint. The device...

  13. Metallic Modular Taper Junctions in Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Timothy McTighe

    2015-08-01

    Full Text Available The emergence of modularity in total hip arthroplasty (THA in the 1980s and 1990s was based on the fact that the benefit of these design features outweighed the risk. The use of metallic modular junctions presents a unique set of advantages and problems for use in THA. The advantages include improvement in fit and fill of the implant to bone, restoration of joint mechanics, reduced complications in revision surgery and reduction of costly inventory. However, the risks or concerns are a little harder to identify and deal with. Certainly corrosion, and fatigue failure are the two most prevalent concerns but now the specifics of fretting wear and corrosive wear increasing particulate debris and the potential biological response is having an impact on the design and potential longevity of the reconstructed hip. Material and designs are facing a shorter life expectancy than what was previously thought, mostly due to an increasing level of physical activity by the patient. Because there are no accurate laboratory test whereby the service life and performance of these implants can be predicted, early controlled clinical evaluations are necessary. Early publication of testing and clinical impressions should be encouraged in an attempt to reduce exposure to potential at risk patients, implants and material. The reduction and possible elimination of risks will require a balancing of all the variables requiring a multidisciplinary endeavor. This paper is designed to review the risk factors, and benefits of modular junctions in total hip arthroplasty (THA. Also some basic engineering principals that can reduce risk factors and improve functionality of modular junctions.

  14. Chromium and cobalt ion concentrations in blood and serum following various types of metal-on-metal hip arthroplasties

    DEFF Research Database (Denmark)

    Jantzen, Christopher; Jørgensen, Henrik L; Duus, Benn R

    2013-01-01

    Widely different metal ion concentrations in blood and serum have been reported with metal-on-metal (MoM) implants. We reviewed the literature on blood and serum ion concentrations of chromium (Cr) and cobalt (Co) following various MoM hip arthroplasties.......Widely different metal ion concentrations in blood and serum have been reported with metal-on-metal (MoM) implants. We reviewed the literature on blood and serum ion concentrations of chromium (Cr) and cobalt (Co) following various MoM hip arthroplasties....

  15. On the matter of synovial fluid lubrication: implications for Metal-on-Metal hip tribology.

    Science.gov (United States)

    Myant, Connor; Cann, Philippa

    2014-06-01

    Artificial articular joints present an interesting, and difficult, tribological problem. These bearing contacts undergo complex transient loading and multi axes kinematic cycles, over extremely long periods of time (>10 years). Despite extensive research, wear of the bearing surfaces, particularly metal-metal hips, remains a major problem. Comparatively little is known about the prevailing lubrication mechanism in artificial joints which is a serious gap in our knowledge as this determines film formation and hence wear. In this paper we review the accepted lubrication models for artificial hips and present a new concept to explain film formation with synovial fluid. This model, recently proposed by the authors, suggests that interfacial film formation is determined by rheological changes local to the contact and is driven by aggregation of synovial fluid proteins. The implications of this new mechanism for the tribological performance of new implant designs and the effect of patient synovial fluid properties are discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Longitudinal magnetic resonance imaging of pseudotumors following metal-on-metal total hip arthroplasty.

    Science.gov (United States)

    Hasegawa, Masahiro; Miyamoto, Noriki; Miyazaki, Shinichi; Wakabayashi, Hiroki; Sudo, Akihiro

    2014-12-01

    The purpose of the study was to determine the natural history of pseudotumors following metal-on-metal total hip arthroplasty (THA) using magnetic resonance imaging (MRI). Initial MRI was conducted at a mean of 36months postoperatively. Follow-up MRI was performed at a mean of 20months after the detection of 24 asymptomatic pseudotumors. Pseudotumor size was determined on MRI. The mean pseudotumor size changed from 729mm(2) to 877mm(2). Pseudotumors increased in size in eight and decreased in six. Ten hips showed no changes. The bigger the pseudotumor size, the more likely the size would increase. In conclusion, pseudotumors frequently change in size. A single MRI study in the clinical decision-making process should be avoided and a longitudinal study should be performed. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Metal release from hip prostheses: cobalt and chromium toxicity and the role of the clinical laboratory.

    Science.gov (United States)

    Campbell, Jonathon R; Estey, Mathew P

    2013-01-01

    Individuals with advanced hip disease suffer from pain, impaired hip function, and decreased quality of life. Roughly one million metal-on-metal (MoM) hip prostheses have been implanted worldwide in order to ameliorate these issues. While most MoM hip replacements are successful, some patients suffer from serious adverse effects secondary to the release of metal debris due to implant wear and corrosion. MoM hip prostheses are comprised predominantly of cobalt and chromium, and the serum concentration of these metal ions has been shown to correlate with both implant wear and the accumulation of metal debris in the periprosthetic tissue. Consequently, measurement of cobalt and chromium concentrations may be useful in the assessment of implant function and the potential for adverse effects in the follow-up of patients with MoM hip prostheses. The purpose of this Mini Review is to describe the adverse biological consequences of metal release from hip prostheses, provide an overview of the clinical utility of cobalt and chromium measurement and the current recommendations for testing, and alert laboratorians and physicians to the many challenges associated with measuring these metal ions.

  18. Midterm results of 36 mm metal-on-metal total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Hawar Akrawi

    2016-01-01

    Full Text Available Background: Despite the many perceived benefits of metal-on-metal (MoM articulation in total hip arthroplasty (THA, there have been growing concerns about metallosis and adverse reaction to metal debris (ARMD. Analysis of size 36 mm MoM articulation THAs is presented. These patients were evaluated for patient characteristics, relationship between blood metal ions levels and the inclination as well as the version of acetabular component, cumulative survival probability at final followup and functional outcome at final followup. Materials and Methods: 288, size 36 mm MoM THAs implanted in 269 patients at our institution from 2004 to 2010 were included in this retrospective study. These patients were assessed clinically for hip symptoms, perioperative complications and causes of revision arthroplasty were analysed. Biochemically, blood cobalt and chromium metal ions level were recorded and measurements of acetabular inclination and version were examined. Radiological evaluation utilizing Metal Artefact Reduction Sequence (MARS MRI was undertaken and implant cumulative survivorship was evaluated. Results: The mean followup was 5 years (range 2–7 years, mean age was 73 years and the mean Oxford hip score was 36.9 (range 5–48. Revision arthroplasty was executed in 20 (7.4% patients, of which 15 patients underwent single-stage revision THA. The causes of revision arthroplasty were: ARMD changes in 6 (2.2% patients, infection in 5 (1.9% patients and aseptic loosening in 5 (1.9% patients. Three (1.1% patients had their hips revised for instability, 1 (0.3% for raised blood metal ions levels. The implant cumulative survival rate, with revision for any reason, was 68.9% at 7 years. Conclusions: Although medium-sized MoM THA with a 36 mm head has a marginally better survivorship at midterm followup, compared to larger size head MoM articulating THA, our findings nonetheless are still worryingly poor in comparison to what has been quoted in the

  19. Failure of total hip implants: metals and metal release in 52 cases.

    Science.gov (United States)

    Jakobsen, Stig S; Lidén, Carola; Søballe, Kjeld; Johansen, Jeanne D; Menné, Torkil; Lundgren, Lennart; Bregnbak, David; Møller, Per; Jellesen, Morten S; Thyssen, Jacob P

    2014-12-01

    The pathogenesis of total joint replacement failure is multifactorial. One hypothesis suggests that corrosion and wear of alloys result in metal ion release, which may then cause sensitization and even implant failure, owing to the acquired immune reactivity. To assess cobalt, nickel and chromium(VI) release from, and the metal composition of, failed metal-on-ethylene total hip replacements. Implant components from 52 revision cases were evaluated with spot tests for free nickel, cobalt, and chromium (VI) ions. Implant composition was determined with X-ray fluorescence spectroscopy, and information on the reason for revision and complications in relation to surgery was collected from the medical charts when possible (72%). For 10 implants, corrosion was further characterized with scanning electron microscopy. We detected cobalt release from three of 38 removed femoral heads and from one of 24 femoral stems. Nickel release was detected from one of 24 femoral stems. No chromium(VI) release was detected. We found that cobalt and nickel were released from some failed total hip arthroplasties, and corrosion was frequently observed. Metal ions and particles corroded from metal-on-polyethylene may play a role in the complex aetiopathology of implant failure. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. The possibilities of magnetic resonance imaging in the diagnostics of complications after metal-on-metal hip arthroplasty

    Directory of Open Access Journals (Sweden)

    A. A. Vergay

    2013-01-01

    Full Text Available Objective: to find adverse periprosthetic local tissue reactions after metal-on-metal hip arthroplasty with ASR XL heads. Material and methods: 119 patients with 134 ASR XL head - Corail prostheses were treated in 2007-2009. The results were studied in 94 cases (105 prostheses - 84%. Average follow-up time consisted 62 ± 3 months. MRI was performed in 12 patients (13 hips who had clinical nonsatisfaction. Obtained data were compared with 21 MRI (24 hips of controlled group with good and perfect clinical results. Results. We found variations of normal periprosthetic tissue condition. Adverse reactions were identified in 10 cases. To improve the quality of pictures we developed special MRI adjustments and regimes of work. Conclusion: MRI diagnostics is indicated for the patients with metal-on-metal total hip arthroplasty in order to identify adverse local tissue reactions. The improvement of picture quality needs special adjustment of MRI equipment.

  1. Outcome of revision arthroplasty for failed metal-on-metal total hip replacements; is there a relation with metal ions?

    Science.gov (United States)

    Iqbal, Hafiz J; Al-Azzani, Waheeb A K; Jackson-Taylor, Esther; Clatworthy, Elizabeth; John, Alun

    2017-05-12

    We aimed to assess the early outcome following revision arthroplasty for failed metal-on-metal (MoM) total hip replacements (THR) due to adverse reaction to metal debris (ARMD). We reviewed 106 consecutive revision arthroplasties. Case notes and radiological investigations were reviewed to assess the complications. Oxford Hip Score (OHS) and Euroqol (EQ-5D-3L) scores were used to assess the functional outcome and improvement of quality of life. At a mean follow-up of 20 months (12-48 months), the mean OHS was 28.7. Pain improved in 61% patients. A majority of patients were in level 2 for all the EQ-5D-3L dimensions. The overall complication rate was 16%. Survivorship free from further revision for any cause was 94.3% at 48 months. There was no correlation between pre-revision blood metal ions and the final outcome. Revision surgery for failed MoM hip replacement due to ARMD is associated with a relatively higher rate of complications and risk of chronic pain. There is poor correlation between serum metal ions and development of ARMD and outcome following revision surgery.

  2. Failure of total hip implants: metals and metal release in 52 cases

    DEFF Research Database (Denmark)

    Jakobsen, Stig Storgaard; Lidén, Carola; Søballe, Kjeld

    2014-01-01

    Background . The pathogenesis of total joint replacement failure is multifactorial. One hypothesis suggests that corrosion and wear of alloys result in metal ion release, which may then cause sensitization and even implant failure, owing to the acquired immune reactivity. Objectives . To assess...... cobalt, nickel and chromium(VI) release from, and the metal composition of, failed metal-on-ethylene total hip replacements. Materials/methods . Implant components from 52 revision cases were evaluated with spot tests for free nickel, cobalt, and chromium (VI) ions. Implant composition was determined...... with X-ray fluorescence spectroscopy, and information on the reason for revision and complications in relation to surgery was collected from the medical charts whenpossible (72%). For 10 implants, corrosion was further characterized with scanning electron microscopy. Results . We detected cobalt release...

  3. Acetabular bone density and metal ions after metal-on-metal versus metal-on-polyethylene total hip arthroplasty; short-term results

    NARCIS (Netherlands)

    Zijlstra, Wierd P.; van der Veen, Hugo C.; van den Akker-Scheek, Inge; Zee, Mark J. M.; Bulstra, Sjoerd K.; van Raay, Jos J. A. M.

    Information on periprosthetic acetabular bone density is lacking for metal-on-metal total hip arthroplasties. These bearings use cobalt-chromium instead of titanium acetabular components, which could lead to stress shielding and hence periprosthetic bone loss. Cobalt and chromium ions have

  4. Outcome and serum ion determination up to 11 years after implantation of a cemented metal-on-metal hip prosthesis.

    Science.gov (United States)

    Lazennec, Jean-Yves; Boyer, Patrick; Poupon, Joel; Rousseau, Marc-Antoine; Roy, Carine; Ravaud, Philippe; Catonné, Yves

    2009-04-01

    Little is known about the long-term outcome of cemented metal-on-metal hip arthroplasties. We evaluated a consecutive series of metal-on-metal polyethylene-backed cemented hip arthroplasties implanted in patients under 60 years of age. 109 patients (134 joint replacements) were followed prospectively for mean 9 (7-11) years. The evaluation included clinical score, radiographic assessment, and blood sampling for ion level determination. At the final review, 12 hips had been revised, mainly because of aseptic loosening of the socket. Using revision for aseptic loosening as the endpoint, the survival rate at 9 years was 91% for the cup and 99% for the stem. In addition, 35 hips showed radiolucent lines at the bone-cement interface of the acetabulum and some were associated with osteolysis. The median serum cobalt and chromium levels were relatively constant over time, and were much higher than the detection level throughout the study period. The cobalt level was 1.5 microg/L 1 year after implantation, and 1.44 microg/L 9 years after implantation. Revisions for aseptic loosening and radiographic findings in the sockets led us to halt metal-on-metal-backed polyethylene cemented hip arthroplasty procedures. If the rigidity of the cemented socket is a reason for loosening, excessive release of metal ions and particles may be involved. Further investigations are required to confirm this hypothesis and to determine whether subluxation, microseparation, and hypersensitivity also play a role.

  5. Detection of incorrect manufacturer labelling of hip components

    Energy Technology Data Exchange (ETDEWEB)

    Durand-Hill, Matthieu; Henckel, Johann; Skinner, John; Hart, Alister [University College London, Institute of Orthopaedics, London (United Kingdom); Burwell, Matthew [Royal United Hospital, Bath (United Kingdom)

    2017-01-15

    We describe the case of a 53-year-old man who underwent a left metal-on-metal hip resurfacing in 2015. Component size mismatch (CSM) was suspected because of the patient's immediate post-operative mechanical symptoms and high metal ion levels. Surgical notes indicated the appropriate combinations of implants were used. However, we detected a mismatch using computed tomography. Revision was performed and subsequent measurements of explanted components confirmed the mismatch. To our knowledge, this case is the first report of a CT method being used in a patient to pre-operatively identify CSM. (orig.)

  6. Clinical usefulness of blood metal measurements to assess the failure of metal-on-metal hip implants

    Science.gov (United States)

    Sampson, Barry; Hart, Alister

    2012-01-01

    In April 2010, a Medicines and Healthcare Products Regulatory Agency safety alert concerning all metal-on-metal (MOM) hip replacements recommended measuring chromium and cobalt concentrations when managing patients with painful prostheses. The need for this review is illustrated by the recent surge in requests for these blood tests from orthopaedic surgeons following this alert. The aim is to provide guidance to laboratories in assessing these requests and advising clinicians on interpretation. First, we summarize the basic terminology regarding the types of hip replacements, with emphasis on the MOM type. Second, we describe the clinical concerns over implant-derived wear debris in the local tissues and distant sites. Analytical aspects of the measurement of the relevant metal ions and what factors affect the levels measured are discussed. The application of inductively coupled plasma mass spectrometry techniques to the measurement of these metals is considered in detail. The biological effects of metal wear products are summarized with local toxicity and systemic biological effects considered, including carcinogenicity, genotoxicity and systemic toxicity. Clinical cases are used to illustrate pertinent points. PMID:22155921

  7. Unusual presentation of failed metal-on-metal total hip arthroplasty with features of neoplastic process

    Directory of Open Access Journals (Sweden)

    Robert P. Runner, MD

    2017-06-01

    Full Text Available Metal-on-metal (MoM total hip arthroplasty (THA is associated with increased incidence of failure from metallosis, adverse tissue reactions, and the formation of pseudotumors. This case highlights a 53-year-old female with an enlarging painful thigh mass 12 years status post MoM THA. Radiographs and advanced imaging revealed an atypical mass with cortical bone destruction and spiculation, concerning for periprosthetic malignancy. Open frozen section biopsy was performed before undergoing revision THA in a single episode of care. This case illustrates that massive pseudotumors can be locally aggressive causing significant femoral bone destruction and may mimic malignancy. It is important that orthopaedic surgeons, radiologists and pathologists understand the relative infrequency of periprosthetic malignancy in MoM THA to mitigate patient concerns, misdiagnosis, and allow for an evidence based discussion when treating massive pseudotumors.

  8. Natural Remission of Major Periprosthetic Osteolysis following Total Hip Arthroplasty with Metal-on-Metal Bearings

    Directory of Open Access Journals (Sweden)

    Tatsuya Tamaki

    2017-01-01

    Full Text Available The natural course of adverse events following the use of metal-on-metal (MoM bearings in total hip arthroplasty (THA is not well known. In this article, we report the case of a patient with asymptomatic major acetabular osteolysis following MoM THA that diminished gradually without any surgical intervention. A 58-year-old male underwent one-stage bilateral MoM THA for bilateral osteoarthritis. Four years after THA, major acetabular osteolysis developed in his right hip without any local or systemic symptoms. The patient underwent a careful radiographic and clinical observation without any surgical intervention because he did not want to undergo revision surgery. The lesion gradually diminished after 7 years, and most of the osteolytic area was replaced by newly formed bone at 10 years. He continues to be followed with no evidence of cup loosening or migration. Our observation suggests that a periprosthetic osteolytic change related to the use of MoM bearings has the potential for natural remission.

  9. Histological characterization of periprosthetic tissue responses for metal-on-metal hip replacement

    Science.gov (United States)

    Phillips, Eual A.; Klein, Gregg R.; Cates, Harold E.; Kurtz, Steven M.; Steinbeck, Marla J.

    2014-01-01

    The histology of periprosthetic tissue from metal-on-metal (MOM) hip devices has been characterized by a variety of methods. The purpose of this study was to compare and evaluate the suitability of two previously developed aseptic lymphocyte-dominated vasculitis-associated lesions (ALVAL) scoring systems for periprosthetic hip tissue responses retrieved from MOM THR systems revised for loosening. Two ALVAL scoring systems (Campbell and Oxford) were used to perform histological analysis of soft tissues from seventeen failed MOM THRs. The predominant reactions for this patient cohort were macrophage infiltration and necrosis, with less than half of the patients (41%) showing a significant lymphocytic response or a high ALVAL reaction (6%). Other morphological changes which varied among patients included hemosiderin accumulation, cartilage formation and heterotopic ossification. Both scoring systems correlated with macrophage and lymphocyte responses and with each other, however given the diversity and variability of the current responses the Oxford-ALVAL system was more suitable for scoring tissues from MOM THR patients revised for loosening. It is important that standardized methods to score MOM tissue responses be used consistently so multiple study results can be compared to one another and a consensus can be generated. PMID:24941402

  10. Do cobalt and chromium levels predict osteolysis in metal-on-metal total hip arthroplasty?

    Science.gov (United States)

    Renner, Lisa; Schmidt-Braekling, Tom; Faschingbauer, Martin; Boettner, Friedrich

    2016-12-01

    Serum metal ions are part of the regular follow-up routine of patients with metal-on-metal total hip arthroplasties (MoM-THA). Increased cobalt levels have been suggested to indicate implant failure and corrosion. (1) Is there a correlation between the size of the osteolysis measured on a CT scan and metal ion levels? (2) Can metal ion levels predict the presence of osteolysis in MoM-THA? (3) Are cobalt and chromium serum levels or the cobalt-chromium-ratio diagnostic for osteolysis? CT scans of patients (n = 75) with a unilateral MoM-THA (Birmingham Hip System, Smith & Nephew, TN, USA) implanted by a single surgeon were reviewed to determine the presence of osteolysis. Statistical analysis was performed to detect its association with metal ion levels at the time of the imaging exam. The incidence of osteolysis was the same in men and women (35.6 vs 35.7 %). The cobalt-chromium-ratio correlates with the size of the osteolysis on the CT scan and the femoral component size in the overall study population (p = 0.050, p = 0.001) and in men (p = 0.002, p = 0.001) but not in women (p = 0.312, p = 0.344). The AUC for the cobalt-chromium-ratio to detect osteolysis was 0.613 (p = 0.112) for the overall population, 0.710 for men (p = 0.021) and 0.453 (p = 0.684) for women. The data suggest that a cut off level of 1.71 for the cobalt-chromium-ratio has a sensitivity of 62.5 % and specificity of 72.4 % to identify male patients with osteolysis. The disproportional increase of cobalt over chromium, especially in male patients with large component sizes can not be explained by wear alone and suggests that other processes (corrosion) might contribute to metal ion levels and might be more pronounced in patients with larger component sizes.

  11. Distributed Analysis of Hip Implants Using Six National and Regional Registries: Comparing Metal-on-Metal with Metal-on-Highly Cross-Linked Polyethylene Bearings in Cementless Total Hip Arthroplasty in Young Patients

    Science.gov (United States)

    Furnes, Ove; Paxton, Elizabeth; Cafri, Guy; Graves, Stephen; Bordini, Barbara; Comfort, Thomas; Rivas, Moises Coll; Banerjee, Samprit; Sedrakyan, Art

    2014-01-01

    Background: The regulation of medical devices has attracted controversy recently because of problems related to metal-on-metal hip implants. There is growing evidence that metal-on-metal implants fail early and cause local and systemic complications. However, the failure associated with metal-on-metal head size is not consistently documented and needs to be communicated to patients and surgeons. The purpose of this study is to compare implant survival of metal on metal with that of metal on highly cross-linked polyethylene. Methods: Using a distributed health data network, primary total hip arthroplasties were identified from six national and regional total joint arthroplasty registries (2001 to 2010). Inclusion criteria were patient age of forty-five to sixty-four years, cementless total hip arthroplasties, primary osteoarthritis diagnosis, and exclusion of the well-known outlier implant ASR (articular surface replacement). The primary outcome was revision for any reason. A meta-analysis of survival probabilities was performed with use of a fixed-effects model. Metal-on-metal implants with a large head size of >36 mm were compared with metal-on-highly cross-linked polyethylene implants. Results: Metal-on-metal implants with a large head size of >36 mm were used in 5172 hips and metal-on-highly cross-linked polyethylene implants were used in 14,372 hips. Metal-on-metal total hip replacements with a large head size of >36 mm had an increased risk of revision compared with metal-on-highly cross-linked polyethylene total hip replacements with more than two years of follow-up, with no difference during the first two years after implantation. The results of the hazard ratios (and 95% confidence intervals) from the multivariable model at various durations of follow-up were 0.95 (0.74 to 1.23) at zero to two years (p = 0.698), 1.42 (1.16 to 1.75) at more than two years to four years (p = 0.001), 1.78 (1.45 to 2.19) at more than four years to six years (p implants and

  12. Formation of a pseudotumor in total hip arthroplasty using a tribological metal-polyethylene pair

    Directory of Open Access Journals (Sweden)

    Lorenzo Fagotti

    2015-12-01

    Full Text Available ABSTRACT The aim here was to report a case of a young adult patient who evolved with tumor formation in the left thigh, 14 years after revision surgery on hip arthroplasty. Davies in 2005 made the first description of this disease in patients undergoing metal-on-metal hip arthroplasty. Over the last decade, however, pseudotumors around metal-on-polyethylene surfaces have become more prevalent. Our patient presented with increased volume of the left thigh 8 years after hip arthroplasty revision surgery. Two years before the arising of the tumor in the thigh, a nodule in the inguinal region was investigated to rule out a malignant neoplastic process, but the results were inconclusive. The main preoperative complaints were pain, functional limitation and marked reduction in the range of motion of the left hip. Plain radiographs showed loosening of acetabular and femoral, and a large mass between the muscle planes was revealed through magnetic resonance imaging of the left thigh. The surgical procedure consisted of resection of the lesion and removal of the components through lateral approach. In respect of total hip arthroplasty, pseudotumors are benign neoplasms in which the bearing surface consists of metal-on-metal, but they can also occur in different tribological pairs, as presented in this case.

  13. Comparison of Complications Following Revision of Metal-on-Metal Versus Metal-on-Polyethylene Total Hip Arthroplasty.

    Science.gov (United States)

    Nishio, Shoji; Fukunishi, Shigeo; Yoshiya, Shinichi; Sing, David C; Hansen, Erik N; Vail, Thomas P

    2017-01-01

    The aim of this study was to examine the clinical characteristics of patients who required revision and the rate of early complications after revision for metal-on-metal total hip arthroplasty (MOM THA) and metal-on-polyethylene total hip arthroplasty (MOP THA). Matched cohorts were selected by retrospective review from a single-center database of revision THAs for failed MOM and MOP THAs from 2010 to 2014. A total of 140 hips in 140 patients comprised the study population; 39 revisions were performed for failed MOM THAs (MOM group), and 101 revisions were performed for failed MOP THAs (MOP group). Data included patient demographics, reason for revision, type of revision procedure, any complication within 90 days after surgery, admission type, and discharge disposition. Primary diagnosis, time from primary THA to revision, operative time, blood loss, and length of stay were reviewed. The analysis showed the time from the index primary procedure to first revision was earlier (P=.01) in the MOM group despite no significant intergroup differences in age, gender, primary diagnosis, or body mass index. Surgical morbidity, as indicated by operative time, blood loss, and length of stay, was lower in the MOM group. The stem was retained more often in the MOM group. There was no significant difference between the groups in overall complication rate. These findings indicate that when performed at an earlier time period before extensive soft tissue reaction to metal ions, revision following MOM THA is not associated with an increased complication rate compared with revision following MOP THA. [Orthopedics. 2017; 40(1):e164-e169.]. Copyright 2016, SLACK Incorporated.

  14. Early rehabilitation in Resurfacing, standard and large head THA patients

    DEFF Research Database (Denmark)

    Penny, Jeannette Østergaard; Varmarken, Jens-Erik; Ovesen, Ole

    2009-01-01

      Introduction For patients in employment a fast rehabilitation is important. The reduced risk of dislocation when using a large-head metal-on-metal articulation theoretically offers a faster rehabilitation than a THA with a 28 mm articulation due to no restrictions. The larger surgical incision...... in the resurfacing patient may impair the early rehabilitation. We aimed to investigate early differences in rehabilitation parameters amongst the different groups. Materials and methods We randomized to resurfacing (n=20), standard 28 mm THA (n=19) and large head MoM THA (n=12). We recorded operation time, blood...... loss, incision length, length of stay and length of sick-absence. Clinical scores: WOMAC, HHS, UCLA activity and steps were recorded preoperatively, at 8 weeks and 6 months, with additional WOMAC at 3 and 6 weeks. Results Results reported for resurfacing, 28 mm and large head THA, respectively...

  15. [History of hip arthroplasty].

    Science.gov (United States)

    Płomiński, Janusz; Kwiatkowski, Krzysztof

    2007-02-01

    The authors present the history of hip prosthesis in treatment of coxarthrosis. Despite eighty years of experience the problem of gaining good and long-term results still exist and is difficult to solve. Even changing the way on cementless stabilization of prosthesis doesn't has result in solving the problem of aseptic loosening of hip arthroplasty. Problems of wear derbies made the producers find new to reduce particulate debris. The future of hip arthroplasty is connected with hip resurfacing. Moreover, the higher number of primary hip plasty the more prosthesis are loosening. The treatment is far more difficult and more expensive.

  16. Hip Implant Systems

    Science.gov (United States)

    ... Orthopaedic Surgeons Information about Soft Tissue Imaging and Metal Ion Testing Information for All Health Care Professionals who Provide Treatment to Patients with a Metal-on-Metal Hip Implant Metal-on-Metal Hip ...

  17. Cobalt serum levels differ in well functioning Birmingham resurfacing and Birmingham modular THA.

    Science.gov (United States)

    Renner, Lisa; Faschingbauer, Martin; Schmidt-Braekling, Tom; Boettner, Friedrich

    2016-05-01

    Metal-on-metal (MoM) bearings are known to release metal ions secondary to wear and corrosion. This may cause local reactions (adverse soft tissue reactions and osteolysis) and systemic effects. Little is known about the exact pattern and the differences between large head MoM total hip replacements (THA) and resurfacings (HR). (1) Is there a difference in metal ion concentrations between HR and MoM-THR using the same bearing design (Birmingham Hip Resurfacing System, Smith & Nephew, Inc. Memphis, TN, USA)? (2) Are metal ion levels changing over time in MoM-THA or HR? (3) Do acetabular inclination angle and femoral component size influence cobalt and chromium levels? Is there a correlation between clinical outcome and metal ion levels? A retrospective analysis was conducted in 77 well functioning unilateral Birmingham HR and 42 well functioning unilateral modular Birmingham MoM-THA (Smith & Nephew, Inc. Memphis, TN, USA) operated on between 2007 and 2012. Blood samples were taken at a minimum of 13 months and subsequent during annual follow-ups. (1) Cobalt levels were significantly higher in MoM-THA compared to HR (p Cobalt is increasing over time in MoM-THA (p = 0.030) whereas metal ions remain stable in HR. (3) Metal ion levels were not affected by acetabular inclination angle and femoral component size in MoM-THA. Chromium levels correlate with the femoral component size (r = -0.240; p = 0.037), the UCLA activity score (r = -0.344; p = 0.003) and the VAS (r = 0.263; p = 0.38) in HR. Considering that HR and MoM-THA used the same MoM bearing design, increased cobalt levels may be related to trunnion wear or corrosion. Elevated cobalt levels should raise concern for corrosion related failure in MoM-THA.

  18. Histologic, serologic, and tribologic findings in failed metal-on-metal total hip arthroplasty: AAOS exhibit selection.

    Science.gov (United States)

    Pelt, Christopher E; Erickson, Jill; Clarke, Ian; Donaldson, Thomas; Layfield, Lester; Peters, Christopher L

    2013-11-06

    Despite multiple changes in second-generation metal-on-metal hip implants, greater-than-expected revision rates have led to alarm. We hypothesized that the finding of intraoperative metallosis would be associated with a high metal load on histologic analysis and that both would be associated with increased wear, greater serum metal ion levels, and predictable biologic responses in the histologic sections. We evaluated the implant positioning, serum ion levels, intraoperative findings of metallosis, wear characteristics of retrieved implants (tribology), histology, and outcomes in a series of eighteen large-diameter metal-on-metal total hip arthroplasties. The arthroplasties were divided into two groups on the basis of the intraoperative finding of metallosis and into two groups on the basis of the metal load score. Intraoperative metallosis was not associated with a high metal load score (p = 0.15). The finding of intraoperative metallosis was associated with greater serum metal ion levels, greater wear rates, and greater complication rates. Aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL) scores were similar between the metallosis and non-metallosis groups (p = 0.49) as well as between the high and low-metal-load groups (p = 0.56).

  19. Friction of ceramic and metal hip hemi-endoprostheses against cadaveric acetabula.

    Science.gov (United States)

    Müller, L P; Degreif, J; Rudig, L; Mehler, D; Hely, H; Rommens, P M

    2004-12-01

    Studies of hip arthroplasty have dealt mainly with total endoprosthesis, while tribology measurement values of hemi-endoprosthetic implants are rare. The small amount of experimental tribological data concerning materials of hemi-endoprosthetic implants in the form of pendulum trials, animal experiments, in vivo measurements on human hip joints and pin on disc studies report friction coefficients between 0.014 and 0.57; the friction coefficients measured in fresh human cadaver hip joints were determined between 0.001 and 0.08. The HEPFlEx-hip simulator was constructed to test the friction coefficients of unipolar femur head hemi-endoprostheses made of metal or ceramic against fresh cadaveric acetabula. Its plane of movement is uniaxial with a flexion-extension movement of +30/-18 degrees . The force is produced pneumatically dynamic with amounts of 2.5 kN. Newborn calf serum serves as a lubricant. We mounted 20 fresh porcine acetabula and 10 fresh human cadaver acetabula in the HEPFlEx-hip simulator and compared the two unipolar femur head hemi-endoprostheses (metal vs. ceramic). The mean friction coefficients against porcine acetabula were micro=0.017-0.082 for ceramic and micro=0.020-0.101 for metal; against human cadaver acetabula micro=0.017-0.083 for ceramic and micro=0.019-0.118 for metal. The frictional coefficient deltas (metal-ceramic) values of all measurements were Deltamicro=0.004 for porcine acetabula and Deltamicro=0.001 for cadaver acetabula. Box-plots graphics document significantly lower frictional coefficients of the ceramics. The lower frictional coefficients of ceramic compared to metal against fresh cadaveric acetabula may have a clinical impact on the process of the protrusion of the corresponding femoral head through the acetabulum.

  20. Uncemented metal-on-metal acetabular component: follow-up of 112 hips for a minimum of 5 years.

    Science.gov (United States)

    Vassan, Uma T; Sharma, Sanjeev; Chowdary, Koganti P; Bhamra, Manjit S

    2007-08-01

    Aseptic loosening is the major cause of implant failure. In cemented hip arthroplasty, failure of the acetabular side is mainly due to lysis caused by wear particles. By using an implant with low wear characteristics and by enhancing acetabular fixation using an uncemented implant, we aimed to reduce acetabular lysis and thereby loosening. This was a retrospective cohort study of 119 hips (101 patients) that had the Uncemented Fitmore cup (Sulzer Orthopedics). In 66 patients, the femoral component was CF-30 (Sulzer) used with cement. In the remaining 35 patients, thrust plate prosthesis (TPP) (Sulzer) was used. Of the 101 patients, 94 (112 hips) were available for study. Mean follow-up of the 94 patients was 7 (5-13) years. The mean preoperative Harris hip score was 38 and the mean postoperative Harris hip score was 89 at the last follow-up. Taking aseptic loosening as the endpoint, the survival rate of the Fitmore cup was 100% at 11 years. The uncemented Fitmore acetabular cup with second generation metal-on-metal articulation showed good results with regard to aseptic loosening in the medium term.

  1. Outcomes following revision surgery performed for adverse reactions to metal debris in non-metal-on-metal hip arthroplasty patients

    Science.gov (United States)

    Judge, A.; Murray, D. W.; Pandit, H. G.

    2017-01-01

    Objectives Few studies have assessed outcomes following non-metal-on-metal hip arthroplasty (non-MoMHA) revision surgery performed for adverse reactions to metal debris (ARMD). We assessed outcomes following non-MoMHA revision surgery performed for ARMD, and identified predictors of re-revision. Methods We performed a retrospective observational study using data from the National Joint Registry for England and Wales. All non-MoMHAs undergoing revision surgery for ARMD between 2008 and 2014 were included (185 hips in 185 patients). Outcome measures following ARMD revision were intra-operative complications, mortality and re-revision surgery. Predictors of re-revision were identified using Cox regression. Results Intra-operative complications occurred in 6.0% (n = 11) of the 185 cases. The cumulative four-year patient survival rate was 98.2% (95% CI 92.9 to 99.5). Re-revision surgery was performed in 13.5% (n = 25) of hips at a mean time of 1.2 years (0.1 to 3.1 years) following ARMD revision. Infection (32%; n = 8), dislocation/subluxation (24%; n = 6), and aseptic loosening (24%; n = 6) were the most common re-revision indications. The cumulative four-year implant survival rate was 83.8% (95% CI 76.7 to 88.9). Multivariable analysis identified three predictors of re-revision: multiple revision indications (hazard ratio (HR) = 2.78; 95% CI 1.03 to 7.49; p = 0.043); selective component revisions (HR = 5.76; 95% CI 1.28 to 25.9; p = 0.022); and ceramic-on-polyethylene revision bearings (HR = 3.08; 95% CI 1.01 to 9.36; p = 0.047). Conclusions Non-MoMHAs revised for ARMD have a high short-term risk of re-revision, with important predictors of future re-revision including selective component revision, multiple revision indications, and ceramic-on-polyethylene revision bearings. Our findings may help counsel patients about the risks of ARMD revision, and guide reconstructive decisions. Future studies attempting to validate the predictors identified should also assess the

  2. Crowe Type I and II DDH managed by large diameter metal-on-metal total hip arthroplasty.

    Science.gov (United States)

    Yalcin, Nadir; Kilicarslan, Kasim; Cicek, Hakan; Kayaalp, Cetin; Yildirim, Hasan

    2011-01-01

    Large bearing metal-on-metal (MOM) total hip arthroplasty (THA) may offer advantages relating to stability and range of motion in patients with Crowe Type I and II developmental dysplasia of the hip (DDH). The purpose of this study was to provide an analysis of the clinical and radiological results of MOM THA in this context and compare the results with a cohort of patients treated with metal-on-polyethylene (MOP) bearing surfaces. 75 hips in 65 patients were treated with cementless MOM THA using large femoral heads (36-56 mm). The mean age of the patients was 47.4 years (29 to 59) and 54 were female. A group of 47 hips (41 patients) treated with conventional THA (screwed cup-polyethylene insert-28 mm head) was used for comparison. The study group was followed up for a mean of 62.1 months (32 to 76). No difference was found between the two groups in relation to improvement in Harris hip score (HHS) (43.1 to 90.3 points in the study group, 42.6 to 89.5 points in the control group, p>0.05). Although the preoperative range of motion in all planes were similar in both groups, the large head group demonstrated greater motion in all planes postoperatively, which was significant (all p=0.001). Additionally, there was a significant difference between groups in relation to the necessity for acetabular structural graft (8% and 31.9%, respectively; p=0.001). No major complications or adverse reactions to metal debris (ARMD) were observed in the study group. The results of large head MOM THA in young and active patients with DDH are similar to conventional THA at early follow-up, but the former offers the advantages of secure acetabular fixation without screws, greater range of motion, and lower risk of dislocation.

  3. International metal-on-metal multidisciplinary teams: do we manage patients with metal-on-metal hip arthroplasty in the same way? An analysis from the International Specialist Centre Collaboration on MOM Hips (ISCCoMH).

    Science.gov (United States)

    Berber, R; Skinner, J; Board, T; Kendoff, D; Eskelinen, A; Kwon, Y-M; Padgett, D E; Hart, A

    2016-02-01

    There are many guidelines that help direct the management of patients with metal-on-metal (MOM) hip arthroplasties. We have undertaken a study to compare the management of patients with MOM hip arthroplasties in different countries. Six international tertiary referral orthopaedic centres were invited to participate by organising a multi-disciplinary team (MDT) meeting, consisting of two or more revision hip arthroplasty surgeons and a musculoskeletal radiologist. A full clinical dataset including history, blood tests and imaging for ten patients was sent to each unit, for discussion and treatment planning. Differences in the interpretation of findings, management decisions and rationale for decisions were compared using quantitative and qualitative methods. Overall agreement between the orthopaedic centres and the recommended treatment plans for the ten patients with MOM hip implants was moderate (kappa = 0.6). Full agreement was seen in a third of cases, however split decisions were also seen in a third of cases. Units differed in their interpretation of the significance of the investigation findings and put varying emphasis on serial changes, in the presence of symptoms. In conclusion, the management of raised or rising blood metal ions, cystic pseudotumours and peri-acetabular osteolysis led to inconsistency in the agreement between centres. Coordinated international guidance and MDT panel discussions are recommended to improve consensus in decision making. A lack of evidence and the subsequent variation in regulator guidance leads to differences in opinions, the clinical impact of which can be reduced through a multi-disciplinary team approach to managing patients with MOM hip implants. Cite this article: Bone Joint J 2016;98-B:179-86. ©2016 The British Editorial Society of Bone & Joint Surgery.

  4. Surface and Subsurface Analyses of Metal-on-Polyethylene Total Hip Replacement Retrievals.

    Science.gov (United States)

    Vuong, Vicky; Pettersson, Maria; Persson, Cecilia; Larsson, Sune; Grandfield, Kathryn; Engqvist, Håkan

    2016-05-01

    Metal-on-polyethylene (MoP) articulations are one of the most reliable implanted hip prostheses. Unfortunately, long-term failure remains an obstacle to the service life. There is a lack of higher resolution research investigating the metallic surface component of MoP hip implants. This study investigates the surface and subsurface features of metallic cobalt chromium molybdenum alloy (CoCrMo) femoral head components from failed MoP retrievals. Unused prostheses were used for comparison to differentiate between wear-induced defects and imperfections incurred during implant manufacturing. The predominant scratch morphology observed on the non-implanted references was shallow and linear, whereas the scratches on the retrievals consisted of largely nonlinear, irregular scratches of varying depth (up to 150 nm in retrievals and up to 60 nm in reference samples). Characteristic hard phases were observed on the surface and subsurface material of the cast samples. Across all samples, a 100-400 nm thick nanocrystalline layer was visible in the immediate subsurface microstructure. Although observation of the nanocrystalline layer has been reported in metal-on-metal articulations, its presence in MoP retrievals and unimplanted prostheses has not been extensively examined. The results suggest that manufacturing-induced surface and subsurface microstructural features are present in MoP hip prostheses prior to implantation and naturally, these imperfections may influence the in vivo wear processes after implantation.

  5. Increased risk of revision of cementless stemmed total hip arthroplasty with metal-on-metal bearings

    Science.gov (United States)

    Pedersen, Alma B; Mäkelä, Keijo; Eskelinen, Antti; Havelin, Leif Ivar; Furnes, Ove; Kärrholm, Johan; Garellick, Göran; Overgaard, Søren

    2015-01-01

    Background and purpose Data from the national joint registries in Australia and England and Wales have revealed inferior medium-term survivorship for metal-on-metal (MoM) total hip arthroplasty (THA) than for metal-on-polyethylene (MoP) THA. Based on data from the Nordic Arthroplasty Register Association (NARA), we compared the revision risk of cementless stemmed THA with MoM and MoP bearings and we also compared MoM THA to each other. Patients and methods We identified 32,678 patients who were operated from 2002 through 2010 with cementless stemmed THA with either MoM bearings (11,567 patients, 35%) or MoP bearings (21,111 patients, 65%). The patients were followed until revision, death, emigration, or the end of the study period (December 31, 2011), and median follow-up was 3.6 (interquartile range (IQR): 2.4–4.8) years for MoM bearings and 3.4 (IQR: 2.0–5.8) years for MoP bearings. Multivariable regression in the presence of competing risk of death was used to assess the relative risk (RR) of revision for any reason (with 95% confidence interval (CI)). Results The cumulative incidence of revision at 8 years of follow-up was 7.0% (CI: 6.0–8.1) for MoM bearings and 5.1% (CI: 4.7–5.6) for MoP bearings. At 6 years of follow-up, the RR of revision for any reason was 1.5 (CI: 1.3–1.7) for MoM bearings compared to MoP bearings. The RR of revision for any reason was higher for the ASR (adjusted RR = 6.4, CI: 5.0–8.1), the Conserve Plus (adjusted RR = 1.7, CI: 1.1–2.5) and “other” acetabular components (adjusted RR = 2.4, CI: 1.5–3.9) than for MoP THA at 6 years of follow-up. Interpretation At medium-term follow-up, the survivorship for cementless stemmed MoM THA was inferior to that for MoP THA, and metal-related problems may cause higher revision rates for MoM bearings with longer follow-up. PMID:25715878

  6. Contact mechanics and elastohydrodynamic lubrication in a novel metal-on-metal hip implant with an aspherical bearing surface.

    Science.gov (United States)

    Meng, Qingen; Gao, Leiming; Liu, Feng; Yang, Peiran; Fisher, John; Jin, Zhongmin

    2010-03-22

    Diameter and diametral clearance of the bearing surfaces of metal-on-metal hip implants and structural supports have been recognised as key factors to reduce the dry contact and hydrodynamic pressures and improve lubrication performance. On the other hand, application of aspherical bearing surfaces can also significantly affect the contact mechanics and lubrication performance by changing the radius of the curvature of a bearing surface and consequently improving the conformity between the head and the cup. In this study, a novel metal-on-metal hip implant employing a specific aspherical bearing surface, Alpharabola, as the acetabular surface was investigated for both contact mechanics and elastohydrodynamic lubrication under steady-state conditions. When compared with conventional spherical bearing surfaces, a more uniform pressure distribution and a thicker lubricant film thickness within the loaded conjunction were predicted for this novel Alpharabola hip implant. The effects of the geometric parameters of this novel acetabular surface on the pressure distribution and lubricant thickness were investigated. A significant increase in the predicted lubricant film thickness and a significant decrease in the dry contact and hydrodynamic pressures were found with appropriate combinations of these geometric parameters, compared with the spherical bearing surface. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  7. Assessments of total hip replacements before and after revision surgery with use of computed tomography with metal artifact reduction techniques

    International Nuclear Information System (INIS)

    Robertson, D.D.; Fishman, E.K.; Kalender, W.A.; Magid, D.; Weiss, P.J.

    1986-01-01

    Radiographic assessment of revision total hip replacements suffers from the inability to provide adequate information regarding bone stock loss. Even CT, with its transaxial orientation, is limited because of metal artifacts. Three metal artifact reduction techniques are available for CT: material-dependent imaging, planar reformation of image data, and missing projection data replacement. These techniques were used to evaluate preoperatively seven patients with revision total hip replacements, and postoperatively eight patients with primary total hip replacements. Despite significant artifacts on the routine transaxial images, the metal artifact-reduced images were of sufficient quality to provide pertinent clinical information in all cases

  8. SU-E-J-230: Effect of Metal Hip Prosthesis On the Accuracy of Electromagnetic Localization and Tracking

    Energy Technology Data Exchange (ETDEWEB)

    Butler, W; Merrick, G; Kurko, B [Wheeling Hospital, Wheeling, WV (United States); Bittner, N [Tacoma\\Valley Radiation Oncology, Tacoma, WA (United States)

    2014-06-01

    Purpose: To quantify the effect of metal hip prosthesis on the ability to track and localize electromagnetic transponders. Methods: Three Calypso transponders were implanted into two prostate phantoms. The geometric center of the transponders were identified on computed tomography and set as the isocenter. With the phantom stationary on the treatment table and the tracking array 14-cm above the isocenter, data was acquired by the Calypso system at 10 Hz to establish the uncertainty in measurements. Transponder positional data was acquired with unilateral hip prostheses of different metallic compositions and then with bilateral hips placed at variable separation from the phantom. Results: Regardless of hip prosthesis composition, the average vector displacement in the presence of a unilateral prosthesis was < 0.5 mm. The greatest contribution to overall vector displacement occurred in the lateral dimension. With bilateral hip prosthesis, the average vector displacement was 0.3 mm. The displacement in the lateral dimension was markedly reduced compared with a unilateral hip, suggesting that there was a countervailing effect with bilateral hip prosthesis. The greatest average vector displacement was 0.6 mm and occurred when bilateral hip prostheses were placed within 4 cm of the detector array. Conclusion: Unilateral and bilateral hip prostheses did not have any meaningful effect on the ability to accurately track electromagnetic transponders implanted in a prostate phantom. At clinically realistic distances between the hip and detection array, the average tracking error is negligible.

  9. SU-E-J-230: Effect of Metal Hip Prosthesis On the Accuracy of Electromagnetic Localization and Tracking

    International Nuclear Information System (INIS)

    Butler, W; Merrick, G; Kurko, B; Bittner, N

    2014-01-01

    Purpose: To quantify the effect of metal hip prosthesis on the ability to track and localize electromagnetic transponders. Methods: Three Calypso transponders were implanted into two prostate phantoms. The geometric center of the transponders were identified on computed tomography and set as the isocenter. With the phantom stationary on the treatment table and the tracking array 14-cm above the isocenter, data was acquired by the Calypso system at 10 Hz to establish the uncertainty in measurements. Transponder positional data was acquired with unilateral hip prostheses of different metallic compositions and then with bilateral hips placed at variable separation from the phantom. Results: Regardless of hip prosthesis composition, the average vector displacement in the presence of a unilateral prosthesis was < 0.5 mm. The greatest contribution to overall vector displacement occurred in the lateral dimension. With bilateral hip prosthesis, the average vector displacement was 0.3 mm. The displacement in the lateral dimension was markedly reduced compared with a unilateral hip, suggesting that there was a countervailing effect with bilateral hip prosthesis. The greatest average vector displacement was 0.6 mm and occurred when bilateral hip prostheses were placed within 4 cm of the detector array. Conclusion: Unilateral and bilateral hip prostheses did not have any meaningful effect on the ability to accurately track electromagnetic transponders implanted in a prostate phantom. At clinically realistic distances between the hip and detection array, the average tracking error is negligible

  10. Complications Are Not Increased With Acetabular Revision of Metal-on-metal Total Hip Arthroplasty.

    Science.gov (United States)

    Penrose, Colin T; Seyler, Thorsten M; Wellman, Samuel S; Bolognesi, Michael P; Lachiewicz, Paul F

    2016-10-01

    Isolated revision of the acetabular component in the setting of total hip arthroplasty has an increased risk of dislocation. With local soft tissue destruction frequently associated with failed metal-on-metal (MoM) bearings, it is presumed that acetabular revision of these hips will have even greater risk of complications. However, no study directly compares the complications of MoM with metal-on-polyethylene (MoP) acetabular revisions. In the context of a large database analysis, we asked the following questions: (1) Are there differences in early medical or wound complications after isolated acetabular revision of MoM and MoP bearing surfaces? (2) Are there differences in the frequency of dislocation, deep infection, and rerevision based on the bearing surface of the original implant? A review of the 100% Medicare database from 2005 to 2012 was performed using International Classification of Diseases, 9th Revision and Current Procedural Terminology codes. We identified 451 patients with a MoM bearing and 628 patients with a MoP bearing who had an isolated acetabular revision and a minimum followup of 2 years. The incidence, odds ratios, and 95% confidence intervals for early medical or wound complications were calculated using a univariate analysis at 30 days with patient sex and age group-adjusted analysis for blood transfusion. The incidence, odds ratio, and 95% confidence intervals for dislocation, deep infection, and rerevision were calculated using a univariate analysis at 30 day, 90 days, 1 year, and 2 years using a subgroup analysis with the Cochran-Mantel-Haenszel test to adjust for patient gender and age groups. There were no differences between the MoM and MoP isolated acetabular revisions in the incidence of 30-day local complications. There was a greater risk of transfusion in the MoP group than the MoM group (134 of 451 [30%] versus 230 of 628 [37%]; odds ratio [OR], 0.731; 95% confidence interval [CI], 0.565-0.948; p = 0.018). There were no

  11. Cryovolcanic Resurfacing on Pluto

    Science.gov (United States)

    Singer, K. N.; Schenk, P.; White, O. L.; Moore, J. M.; McKinnon, W. B.; Grundy, W. M.; Spencer, J. R.; Stern, A.; Cook, J. C.; Nimmo, F.; Howard, A. D.; Cruikshank, D. P.; Beyer, R. A.; Umurhan, O. M.; Lauer, T.; Weaver, H. A., Jr.; Young, L. A.; Ennico Smith, K.

    2017-12-01

    Pluto displays several different young geologic terrains with few-to-no identifiable impact craters. Distinct terrains to the southwest of the informally named Sputnik Planitia may have been resurfaced by cryovolcanic processes, of a type and scale so far unique to Pluto [1,2]. The most prominent structures are two very large mounds with deep central depressions. The informally named Wright Mons stands 4 km high and the main mound spans 150 km and Piccard Mons is 7 km high and 225 km wide. Hummocky terrain with a characteristic wavelength of 8-12 km covers the flanks of Wright Mons and much of the surrounding terrain. Smaller boulders, blocks, slabs, or ridges on the order of a few km are superimposed on the hummocks. The large-scale slopes across the broad flanks of the Wright Mons are 3-5°. The central depression walls are typically 10°, but reach 20° in some locations. A number of other cavi or irregular depressions of various sizes (a few to 30 km) are scattered throughout the terrain and do not appear to be impact craters. There are few signs of potential individual flows but the large-scale hummocky texture is suggestive of viscous flow. We will explore a number of potential mechanisms for creation of Wright and Piccard Mons and the nearby terrains. These unique terrains present modeling challenges for building relatively young, large cryovolcanic constructs on outer solar system bodies. Tidal heating is thought to end early in Pluto-system history [3] and radiogenic heating levels are relatively low [4], although a subsurface ocean may still persist into the present day [5]. We will discuss the possible volcanic materials on Pluto and their mobility under different heating scenarios, as well as other possible emplacement processes. [1] Moore et al., (2016) Science 351, 1284-1293. [2] Singer et al. (2016) LPSC absract 47, 2276. [3] Cheng et al. (2014) Icarus 233, 242-258. [4] McKinnon et al. (1997) In: Stern, S.A., Tholen, D.J. (Eds.), Pluto and Charon

  12. 21 CFR 888.3353 - Hip joint metal/ceramic/polymer semi-constrained cemented or nonporous uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... cemented or nonporous uncemented prosthesis. 888.3353 Section 888.3353 Food and Drugs FOOD AND DRUG... prosthesis. (a) Identification. A hip joint metal/ceramic/polymer semi-constrained cemented or nonporous uncemented prosthesis is a device intended to be implanted to replace a hip joint. This device limits...

  13. Th1 type lymphocyte reactivity to metals in patients with total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Finnegan Alison

    2008-02-01

    Full Text Available Abstract Background All prostheses with metallic components release metal debris that can potentially activate the immune system. However, implant-related metal hyper-reactivity has not been well characterized. In this study, we hypothesized that adaptive immunity reaction(s, particularly T-helper type 1 (Th1 responses, will be dominant in any metal-reactivity responses of patients with total joint replacements (TJAs. We tested this hypothesis by evaluating lymphocyte reactivity to metal "ions" in subjects with and without total hip replacements, using proliferation assays and cytokine analysis. Methods Lymphocytes from young healthy individuals without an implant or a history of metal allergy (Group 1: n = 8 were used to assess lymphocyte responses to metal challenge agents. In addition, individuals (Group 2: n = 15 with well functioning total hip arthroplasties (average Harris Hip Score = 91, average time in-situ 158 months were studied. Age matched controls with no implants were also used for comparison (Group 3, n = 8, 4 male, 4 female average age 70, range 49–80. Group 1 subjects' lymphocyte proliferation response to Aluminum+3, Cobalt+2, Chromium+3, Copper+2, Iron+3, Molybdenum+5, Manganeese+2, Nickel+2, Vanadium+3 and Sodium+2 chloride solutions at a variety of concentrations (0.0, 0.05, 0.1, 0.5, 1.0 and 10.0 mM was studied to establish toxicity thresholds. Mononuclear cells from Group 2 and 3 subjects were challenged with 0.1 mM CrCl3, 0.1 mM NiCl2, 0.1 mM CoCl2 and approx. 0.001 mM titanium and the reactions measured with proliferation assays and cytokine analysis to determine T-cell subtype prominence. Results Primary lymphocytes from patients with well functioning total hip replacements demonstrated a higher incidence and greater magnitude of reactivity to chromium than young healthy controls (p 2 fold stimulation index response, p 10 mM. The differential secretion of signature T-cell subsets' cytokines (Th1 and Th2 lymphocytes

  14. Prospective analysis of human leukocyte functional tests reveals metal sensitivity in patients with hip implant

    Science.gov (United States)

    2013-01-01

    Background The aim of the study was to examine the reactivity of peripheral human leukocytes to various metal ions prior and following hip replacement in order to investigate implant-induced metal sensitivity. Methods Three patient groups were set up: (1) individuals without implants and no history of metal allergy (7 cases), (2) individuals without implants and known history of metal allergy (7 cases), and (3) patients undergoing cementless hip replacement (40 cases). Blood samples were taken in groups 1 and 2 at three different occasions; in group 3, prior and 3, 6, 12, 24, and 36 months after surgery. Peripheral leukocytes were separated and left either untreated or challenged with Ti, NiCl2, CoCl2, CrCl3, and phytohemagglutinin. Cell proliferation, cytokine release, and leukocyte migration inhibition assays were performed. Metal-induced reactivity was considered when all three assays showed significant change. Skin patch tests were also carried out. Results Both skin patch tests and leukocyte functional tests were negative in group 1, and both were positive in group 2. In group 3, after 6 months, 12% of the patients showed reactivity to the tested metals except for NiCl2. Following the 36-month period, 18% of group three became sensitive to metals (including all the earlier 12%). In contrast, patch tests were negative at each time point in group 3. Conclusions Orthopedic implant material may induce metal reactivity after implantation in a manner where susceptibility is yet to be elucidated. Leukocyte triple assay technique might be a useful tool to test implant material-related sensitivity. PMID:23680415

  15. Relationship between Pelvic Incidence Angle and Blood Concentration of Chromium and Cobalt Ions after Metal-on-Metal Hip Replacement: A Brief Report.

    Science.gov (United States)

    Pernaa, K; Saltychev, M; Mäkelä, K

    2018-03-01

    The wear of metal-on-metal hip implants may increase chromium or cobalt ion blood level. This phenomenon may depend among other things on the particularity of spinopelvic anatomy. The effect of pelvic incidence angle on the wear of metal-on-metal hip implants is not known. The objective of the study was to investigate whether such effect does exist. The pelvic incidence and inclination of acetabular component angles of 89 patients after unilateral metal-on-metal hip replacement were compared with blood level of chromium and cobalt ions using Pearson correlation coefficient. No significant correlations between pelvic incidence angle and the metal ion blood levels were observed. The correlation coefficients varied from -0.02 to 0.2 and all p values were >0.05. No evidence was found on the effect of pelvic incidence angle on metal wear after metal-on-metal hip replacement when measured by the blood levels of chromium and cobalt ions. It is reasonable to assume that other factors than pelvic tilt may affect the rate of implant wear.

  16. Comparison of different pseudotumor grading systems in a single cohort of metal-on-metal hip arthroplasty patients

    Energy Technology Data Exchange (ETDEWEB)

    Weegen, W. van der; Wullems, J.A.; Das, H.P. [St. Anna Hospital, Department of Orthopaedic Surgery, Geldrop (Netherlands); Brakel, K.; Horn, R.J. [St. Anna Hospital, Department of Radiology, Geldrop (Netherlands); Pilot, P. [Reinier de Graaf Gasthuis, Department of Orthopaedic Surgery, Delft (Netherlands); Nelissen, R.G. [Leids Universitair Medisch Centrum, Department of Orthopaedic Surgery, Leiden (Netherlands)

    2014-02-15

    Follow-up of pseudotumors observed with metal-artefact reducing sequence (MARS)-magnetic resonance imaging (MRI) following metal-on-metal total hip arthroplasty (MoMTHA) depends on how severe these pseudotumors are graded. Several pseudotumor grading systems for MARS-MRI have emerged but little is known of their validity. We studied the intra- and interobserver reliability of three different pseudotumor grading systems in a single cohort of MoMTHA. Two experienced musculoskeletal radiologists independently used three different pseudotumor grading systems for classifying MARS-MRI results of the same cohort of 42 MoMTHA patients (49 hips, mean follow-up 5.2 years). Intraobserver and interobserver reliability for each grading system was measured using Cohen's kappa (κ). Variance in pseudotumor severity grading between systems was analyzed. Intraobserver reliability on grading pseudotumor severity with the Anderson, Matthies, and Hauptfleisch grading system scored 0.47, 0.10, and 0.35 (observer 1), and 0.75, 0.38, and 0.42 (observer 2), respectively. Interobserver reliability scores for pseudotumor severity were 0.58, 0.23, and 0.34, respectively. Intraobserver reliability for grading pseudotumor severity on MARS-MRI ranged from poor to good, dependent on observer and grading system used. Interobserver reliability scored best with the Anderson system. A more succinct pseudotumor severity grading system is needed for clinical use. (orig.)

  17. Modular Neck vs Nonmodular Femoral Stems in Total Hip Arthroplasty-Clinical Outcome, Metal Ion Levels, and Radiologic Findings

    DEFF Research Database (Denmark)

    Mikkelsen, Rasmus T; Fløjstrup, Marianne; Lund, Christian

    2017-01-01

    BACKGROUND: Modular neck femoral stem (MNFS) for total hip arthroplasty (THA) was introduced to optimize the outcome, but created concerns about pain, elevated blood metal ion levels, and adverse reaction to metal debris such as pseudotumors (PTs), related to corrosion between femoral neck and st...

  18. [Choice of hip prosthesis in patients younger than 50 years

    NARCIS (Netherlands)

    Schreurs, B.W.; Busch, V.J.; Veth, R.P.H.

    2007-01-01

    There is no agreement about the most ideal type of hip prosthesis to be used in patients younger than 50 years. The most commonly used hip prostheses in patients younger than 50 years are uncemented or resurfacing prostheses and to a lesser extent cemented prostheses. A good result of a hip

  19. A study of TiN-coated metal-on-polymer bearing materials for hip prosthesis

    Science.gov (United States)

    Lee, Sung Bai; Choi, Jin Young; Park, Won Woong; Jeon, Jun Hong; Won, Sung Ok; Byun, Ji Young; Lim, Sang Ho; Han, Seung Hee

    2010-08-01

    The TiN-coated metal-on-polymer hip prosthetic pair has the potential to reduce wear debris of UHMWPE (ultra-high molecular weight polyethylene) and to prevent metallic-ion-induced cytotoxicity. However, high quality and adherent film is a key to the clinical success of hip prostheses. In this study, titanium nitride (TiN) films were deposited on stainless steel using plasma immersion ion implantation & deposition (PIII&D) technique to create high-quality film and an adherent interface. The chemical state and composition were analyzed by X-ray photoelectron spectroscopy (XPS), Auger electron spectroscopy (AES) and energy dispersive spectroscopy (EDS). The mechanical properties of the films were characterized using a micro-hardness tester and a pin-on-disk wear tester, and an x-ray diffractometer (XRD) was used for a crystallographic analysis. The PIII&D-treated TiN films showed a stoichiometric and (200) preferred orientation and micro-hardness up to 150 % higher than untreated film. A TiN-coated specimen using the PIII&D process also showed less UHMWPE wear compared to untreated specimens. The volumetric wear rate of UHMWPE could be reduced by as much as 42 % compared to when Co-Cr alloy was used. The results of this study show that advanced TiN-coating via the PIII&D process is a viable means of reducing UHMWPE wear in the metal-on-polymer bearing couple.

  20. Optimization of metal artefact reduction (MAR) sequences for MRI of total hip prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Toms, A.P., E-mail: andoni.toms@nnuh.nhs.u [Department of Radiology, Norfolk and Norwich University Hospital Trust, Norwich, Norfolk NR4 7UY (United Kingdom); Smith-Bateman, C.; Malcolm, P.N.; Cahir, J. [Department of Radiology, Norfolk and Norwich University Hospital Trust, Norwich, Norfolk NR4 7UY (United Kingdom); Graves, M. [University Department of Radiology, Addenbrooke' s Hospital, Cambridge (United Kingdom)

    2010-06-15

    Aim: To describe the relative contribution of matrix size and bandwidth to artefact reduction in order to define optimal sequence parameters for metal artefact reduction (MAR) sequences for MRI of total hip prostheses. Methods and materials: A phantom was created using a Charnley total hip replacement. Mid-coronal T1-weighted (echo time 12 ms, repetition time 400 ms) images through the prosthesis were acquired with increasing bandwidths (150, 300, 454, 592, and 781 Hz/pixel) and increasing matrixes of 128, 256, 384, 512, 640, and 768 pixels square. Signal loss from the prosthesis and susceptibility artefact was segmented using an automated tool. Results: Over 90% of the achievable reduction in artefacts was obtained with matrixes of 256 x 256 or greater and a receiver bandwidth of approximately 400 Hz/pixel or greater. Thereafter increasing the receiver bandwidth or matrix had little impact on reducing susceptibility artefacts. Increasing the bandwidth produced a relative fall in the signal-to-noise ratio (SNR) of between 49 and 56% for a given matrix, but, in practice, the image quality was still satisfactory even with the highest bandwidth and largest matrix sizes. The acquisition time increased linearly with increasing matrix parameters. Conclusion: Over 90% of the achievable metal artefact reduction can be realized with mid-range matrices and receiver bandwidths on a clinical 1.5 T system. The loss of SNR from increasing receiver bandwidth, is preferable to long acquisition times, and therefore, should be the main tool for reducing metal artefact.

  1. Cobalt to Chromium Ratio is Not a Key Marker for Adverse Local Tissue Reaction (ALTR) in Metal on Metal Hips.

    Science.gov (United States)

    Fehring, Thomas K; Carter, Joshua L; Fehring, Keith A; Odum, Susan M; Griffin, William L

    2015-09-01

    The diagnosis of adverse local tissue reaction (ALTR) after metal-on-metal total hip arthroplasty (MoMTHA) presents a significant challenge. No single biomarker is specific for ALTR. The purpose of this study was to determine if the ratio of cobalt to chromium ions is useful for diagnosing ALTR in MoMTHA. In 89 bearing-related revision THAs, preoperative cobalt and chromium ion levels were compared to an intraoperative soft tissue damage grading scale. The average cobalt to chromium ratio was 2.96 (0-20). There was no correlation between the tissue scale and the cobalt to chromium ratio (R=0.095; P=0.41). Many variables affecting ion production/excretion mitigate the use of the ion ratio. The cobalt to chromium ratio is not a predictive biomarker for ALTR in MoMTHA. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. The effect of a metal hip prosthesis on the radiation dose in therapeutic photon beam irradiations

    Energy Technology Data Exchange (ETDEWEB)

    Lin, S.-Y.; Chu, T.-C. E-mail: tcchu@mx.nthu.edu.tw; Lin, J.-P.; Liu, M.-T

    2002-07-01

    Prostate and cervical cancer patients are often treated with external X-ray beams of bi-lateral incidence. Such treatment may incur some dose effect that cannot be predicted precisely in commercial treatment planning systems (TPS) for patients having undergone total hip replacement. This study performs a Monte Carlo (MC) simulation and an analytical calculation (convolution superposition algorithm which is implemented in ADAC TPS) of a 6 MV, 5x5 cm{sup 2} X-ray beam incident into water with the existence of hip prosthesis, e.g. Ti6Al4V and CoCrMo alloy. The results indicate that ADAC TPS cannot precisely account for the scatter and backscatter radiation that a metal hip prosthesis causes. For percent depth dose (PDD) curves, the maximum underdosage of ADAC TPS up to 5 mm above the interface between dense material and water is 5%, 20% and 27% for PDD{sub Bone}, PDD{sub Ti} and PDD{sub Co}, respectively. The dose re-buildup, which occurs behind the hip region, becomes more and more obvious for denser medium existed in water. Increasing inhomogeneity also enhances the underdosage of ADAC for greater depth (>10 cm), as the figures of nearly 2% in PDD{sub Bone}, PDD{sub Ti} and 4-5% in PDD{sub Co} reveal. Overestimating the attenuated power of high-density non-water material in ADAC TPS causes this underdosage. For dose profiles, no significant differences were found in Profile{sub Bone} at any depth. Profile{sub Ti} reveals that MC slightly exceeds ADAC at off-axis position 1.0-2.0 cm. Profile{sub Co} reveals this more obviously. This finding means that scatter radiation from these denser materials is significant and cannot be predicted precisely in ADAC.

  3. Characterization of protein degradation in serum-based lubricants during simulation wear testing of metal-on-metal hip prostheses.

    Science.gov (United States)

    Maskiewicz, Victoria K; Williams, Paul A; Prates, Sarah J; Bowsher, John G; Clarke, Ian C

    2010-08-01

    A size exclusion high performance liquid chromatography (SEC-HPLC) method has been developed which is capable of separation and quantitation of bovine serum albumin (BSA) and bovine serum globulin (BSG) components of serum-based lubricant (SBL) solutions. This allowed characterization of the stability profiles of these proteins when acting as lubricants during hip wear simulation, and identification of wear-specific mechanisms of degradation. Using cobalt-chromium metal-on-metal (MOM) hip joints, it was observed that BSA remained stable for up to 3 days (215K cycles) of wear testing after which the protein degraded in a fairly linear fashion. BSG on the other hand, began to degrade immediately and in a linear fashion with a rate constant of 5% per day. Loss of both proteins occurred via the formation of high molecular weight aggregates which precipitated out of solution. No fragmentation of the polypeptide backbone of either protein was observed. Data obtained suggest that protein degradation was not due to microbial contamination, denaturation at the air-water interface, or frictional heating of articulating joint surfaces in these studies. We conclude that the primary source of protein degradation during MOM simulation testing occurs via high shear rates experienced by SBL solutions at articulating surfaces, possibly coupled with metal-protein interactions occurring as new and reactive metal surfaces are generated during wear testing. The development of this analytical methodology will allow new studies to clarify the role of SBL solutions in wear simulation studies and the interactions and lubricating properties of serum proteins with prosthetic surfaces other than MOM.

  4. Comparing return to sport activities after short metaphyseal femoral arthroplasty with resurfacing and big femoral head arthroplasties.

    Science.gov (United States)

    Karampinas, Panagiotis K; Papadelis, Eustratios G; Vlamis, John A; Basiliadis, Hlias; Pneumaticos, Spiros G

    2017-07-01

    Young patients feel that maintaining sport activities after total hip arthroplasty constitutes an important part of their quality of life. The majority of hip surgeons allow patients to return to low-impact activities, but significant caution is advised to taking part in high-impact activities. The purpose of this study is to compare and evaluate the post-operative return to daily living habits and sport activities following short-metaphyseal hip and high functional total hip arthroplasties (resurfacing and big femoral head arthroplasties). In a study design, 48 patients (55 hips) were enrolled in three different comparative groups, one with the short-metaphyseal arthroplasties, a second with high functional resurfacing arthroplasties and a third of big femoral head arthroplasties. Each patient experienced a clinical examination and evaluated with Harris Hip Score, WOMAC, Sf-36, UCLA activity score, satisfaction VAS, anteroposterior and lateral X-rays of the hip and were followed in an outpatient setting for 2 years. Statistical analysis revealed no notable differences between the three groups regarding their demographic data however significant differences have been found between preoperative and postoperative clinical scores of each group. Also, we fail to reveal any significant differences when comparing data of all three groups at the final 2 years postoperative control regarding their clinical scores. The overall outcome of all three groups was similar, all the patients were satisfied and returned to previous level of sport activities. Short metaphyseal hip arthroplasties in young patients intending to return to previous and even high impact sport activities, similar to high functional resurfacing, big femoral head arthroplasties. Short stems with hard on hard bearing surfaces might become an alternative to standard stems and hip resurfacing.

  5. Edge loading has a paradoxical effect on wear in metal-on-polyethylene total hip arthroplasties.

    Science.gov (United States)

    Harris, William H

    2012-11-01

    Edge wear is an adverse factor that can negatively impact certain THAs. In some metal-on-metal THAs, it can lead to adverse tissue reactions including aseptic lymphocytic vasculitis-associated lesions and even to pseudotumor formation. In some ceramic-on-ceramic THAs, it can lead to squeaking and/or stripe wear. Edge wear in metal-on-metal and ceramic-on-ceramic THAs can also be associated with accelerated wear across the articulation of these joints. I asked: Does edge wear occur in metal-on-polyethylene (MOP) articulations? And if so, does it increase joint wear? I examined the evidence in the literature for edge wear occurring in MOP THA and then assessed the evidence in the literature for data supporting the concept that edge wear in MOP hips could accelerate wear across the articulation over time. Extensive data in the literature confirm edge wear is common in MOP THA. Surprisingly, the evidence does not support that it accelerates wear across the articulation. In fact, substantial data support the concept that it does not. These observations suggest, in terms of edge wear accelerating overall wear, MOP articulation may have a privileged position compared to hard-on-hard THA articulations.

  6. Growth of an intrapelvic pseudotumor associated with a metal-on-metal total hip arthroplasty after revision arthroplasty causing a femoral nerve neuropathy

    Directory of Open Access Journals (Sweden)

    Patrick Leung, MD

    2016-09-01

    Full Text Available The development of pseudotumors is not uncommon with metal-on-metal total hip arthroplasty. Pseudotumors that dissect into the retroperitoneal space can cause symptoms of nerve compression. We describe a case of a 53-year-old male with a metal-on-metal total hip arthroplasty who developed mild symptoms of a femoral nerve neuropathy 6 years postoperatively. Revision arthroplasty to a ceramic-on-polyethylene articulation and debridement of the pseudotumor was performed. Postoperatively, the patient's femoral neuropathy progressed and a repeat magnetic resonance imaging showed an increase in size of the pseudotumor despite the removal of the offending metal-on-metal articulation. The patient subsequently underwent a laparoscopic excision of the retroperitoneal pseudotumor. By 17 months post laparoscopic excision of the pseudotumor, the patient's motor deficits resolved, however, sensory deficits persisted in the anteromedial thigh.

  7. Hip arthroplasty for treatment of advanced osteonecrosis: comprehensive review of implant options, outcomes and complications

    Directory of Open Access Journals (Sweden)

    Waewsawangwong W

    2016-06-01

    Full Text Available Warit Waewsawangwong, Pirapat Ruchiwit, James I Huddleston, Stuart B Goodman Department of Orthopedic Surgery, Stanford University, Stanford, CA, USA Abstract: Surgical treatment for late stage (post-collapse osteonecrosis of the femoral head is controversial. In these situations, the outcome of joint preservation procedures is poor. There are several arthroplasty options for late-stage disease. The clinical outcomes of hemiarthroplasty and hemiresurfacing are unpredictable because of progressive acetabular cartilage degeneration. Total hip resurfacing may be associated with further vascular insult to the femoral head and early failure of the implant. Total hip replacement with metal-on-conventional polyethylene bearing surfaces has been the gold standard, but implant survivorship is limited in young active patients due to wear and osteolysis. Newer alternative bearing surfaces may have improved wear characteristics, but their durability must be confirmed in longer-term studies. Keywords: hip arthroplasty, advanced osteonecrosis, implant options, outcomes, complications

  8. Patient-Reported Outcomes After Revision of Metal-on-Metal Total Bearings in Total Hip Arthroplasty.

    Science.gov (United States)

    Mata-Fink, Ana; Philipson, Daniel J; Keeney, Benjamin J; Ramkumar, Dipak B; Moschetti, Wayne E; Tomek, Ivan M

    2017-04-01

    Failure of metal-on-metal (MOM) total hip arthroplasty (THA) bearings is often accompanied by an aggressive local reaction associated with destruction of bone, muscle, and other soft tissues around the hip. Little is known about whether patient-reported physical and mental function following revision THA in MOM patients is compromised by this soft tissue damage, and whether revision of MOM THA is comparable with revision of hard-on-soft bearings such as metal-on-polyethylene (MOP). We identified 75 first-time MOM THA revisions and compared them with 104 first-time MOP revisions. Using prospective patient-reported measures via the Veterans RAND-12, we compared Physical Component Score and Mental Component Score function at preoperative baseline and postoperative follow-up between revision MOM THA and revision MOP THA. Physical Component Score did not vary between the groups preoperatively and at 1 month, 3 months, and 1 year postoperatively. Mental Component Score preoperatively and 1 and 3 months postoperatively were lower in patients in the MOM cohort compared with patients with MOP revisions (baseline: 43.7 vs 51.3, P revision cohorts. Postrevision physical function in revised MOM THA patients does not differ significantly from the outcomes of revised MOP THA. Mental function is markedly lower in MOM patients at baseline and early in the postoperative period, but does not differ from MOP patients at 1 year after revision. This information should be useful to surgeons and physicians facing MOM THA revision. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Bearing Change to Metal-On-Polyethylene for Ceramic Bearing Fracture in Total Hip Arthroplasty; Does It Work?

    Science.gov (United States)

    Lee, Soong Joon; Kwak, Hong Suk; Yoo, Jeong Joon; Kim, Hee Joong

    2016-01-01

    We evaluated the short-term to midterm results of reoperation with bearing change to metal-on-polyethylene (MoP) after ceramic bearing fracture in ceramic-on-ceramic total hip arthroplasty. Nine third-generation ceramic bearing fractures (6 heads and 3 liners) were treated with bearing change to MoP. Mean age at reoperation was 52.7 years. Mean follow-up was 4.3 years. During follow-up, 2 of 3 liner-fractured hips and 1 of 6 head-fractured hips showed radiologic signs of metallosis and elevated serum chromium levels. Re-reoperation with bearing rechange to a ceramic head was performed for the hips with metallosis. One liner-fractured hip had periprosthetic joint infection. Dislocation occurred in 3 hips. From our experience, bearing change to MoP is not a recommended treatment option for ceramic bearing fracture in total hip arthroplasty. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Comparison of metal ion concentrations and implant survival after total hip arthroplasty with metal-on-metal versus metal-on-polyethylene articulations.

    Science.gov (United States)

    Dahlstrand, Henrik; Stark, André; Wick, Marius C; Anissian, Lucas; Hailer, Nils P; Weiss, Rüdiger J

    2017-10-01

    Background and purpose - Large metal-on-metal (MoM) articulations are associated with metal wear and corrosion, leading to increased metal ion concentrations and unacceptable revision rates. There are few comparative studies of 28-mm MoM articulations with conventional metal-on-polyethylene (MoP) couplings. We present a long-term follow-up of a randomized controlled trial comparing MoM versus MoP 28-mm articulations, focused on metal ions and implant survival. Patients and methods - 85 patients with a mean age of 65 years at surgery were randomized to a MoM (Metasul) or a MoP (Protasul) bearing. After 16 years, 38 patients had died and 4 had undergone revision surgery. 13 patients were unavailable for clinical follow-up, leaving 30 patients (n = 14 MoM and n = 16 MoP) for analysis of metal ion concentrations and clinical outcome. Results - 15-year implant survival was similar in both groups (MoM 96% [95% CI 88-100] versus MoP 97% [95% CI 91-100]). The mean serum cobalt concentration was 4-fold higher in the MoM (1.5 μg/L) compared with the MoP cohort (0.4 μg/L, p concentration was double in the MoM (2.2 μg/L) compared with the MoP cohort (1.0 μg/L, p = 0.05). Mean creatinine levels were similar in both groups (MoM 93 μmol/L versus MoP 92 μmol/L). Harris hip scores differed only marginally between the MoM and MoP cohorts. Interpretation - This is the longest follow-up of a randomized trial on 28-mm MoM articulations, and although implant survival in the 2 groups was similar, metal ion concentrations remained elevated in the MoM cohort even in the long term.

  11. Transient elastohydrodynamic lubrication analysis of a novel metal-on-metal hip prosthesis with a non-spherical femoral bearing surface.

    Science.gov (United States)

    Meng, Q E; Liu, F; Fisher, J; Jin, Z M

    2011-01-01

    Effective lubrication performance of metal-on-metal hip implants only requires optimum conformity within the main loaded area, while it is advantageous to increase the clearance in the equatorial region. Such a varying clearance can be achieved by using non-spherical bearing surfaces for either acetabular or femoral components. An elastohydrodynamic lubrication model of a novel metal-on-metal hip prosthesis using a non-spherical femoral bearing surface against a spherical cup was solved under loading and motion conditions specified by ISO standard. A full numerical methodology of considering the geometric variation in the rotating non-spherical head in elastohydrodynamic lubrication solution was presented, which is applicable to all non-spherical head designs. The lubrication performance of a hip prosthesis using a specific non-spherical femoral head, Alpharabola, was analysed and compared with those of spherical bearing surfaces and a non-spherical Alpharabola cup investigated in previous studies. The sensitivity of the lubrication performance to the anteversion angle of the Alpharabola head was also investigated. Results showed that the non-spherical head introduced a large squeeze-film action and also led to a large variation in clearance within the loaded area. With the same equatorial clearance, the lubrication performance of the metal-on-metal hip prosthesis using an Alpharabola head was better than that of the conventional spherical bearings but worse than that of the metal-on-metal hip prosthesis using an Alpharabola cup. The reduction in the lubrication performance caused by the initial anteversion angle of the non-spherical head was small, compared with the improvement resulted from the non-spherical geometry.

  12. Characterization of wear debris from metal-on-metal hip implants during normal wear versus edge-loading conditions.

    Science.gov (United States)

    Kovochich, Michael; Fung, Ernest S; Donovan, Ellen; Unice, Kenneth M; Paustenbach, Dennis J; Finley, Brent L

    2018-04-01

    Advantages of second-generation metal-on-metal (MoM) hip implants include low volumetric wear rates and the release of nanosized wear particles that are chemically inert and readily cleared from local tissue. In some patients, edge loading conditions occur, which result in higher volumetric wear. The objective of this study was to characterize the size, morphology, and chemistry of wear particles released from MoM hip implants during normal (40° angle) and edge-loading (65° angle with microseparation) conditions. The mean primary particle size by volume under normal wear was 35 nm (range: 9-152 nm) compared with 95 nm (range: 6-573 nm) under edge-loading conditions. Hydrodynamic diameter analysis by volume showed that particles from normal wear were in the nano- (edge-loading conditions generated particles that ranged from Edge-loading conditions generated more elongated particles (4.5%) (aspect ratio ≥ 2.5) and more CoCr alloy particles (9.3%) compared with normal wear conditions (1.3% CoCr particles). By total mass, edge-loading particles contained approximately 640-fold more cobalt than normal wear particles. Our findings suggest that high wear conditions are a potential risk factor for adverse local tissue effects in MoM patients who experience edge loading. This study is the first to characterize both the physical and chemical characteristics of MoM wear particles collected under normal and edge-loading conditions. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 986-996, 2018. © 2017 Wiley Periodicals, Inc.

  13. Pseudotumour incidence, cobalt levels and clinical outcome after large head metal-on-metal and conventional metal-on-polyethylene total hip arthroplasty MID-TERM RESULTS OF A RANDOMISED CONTROLLED TRIAL

    NARCIS (Netherlands)

    van der Veen, H. C.; Reininga, I. H. F.; Zijlstra, W. P.; Boomsma, M. F.; Bulstra, S. K.; van Raay, J. J. A. M.

    2015-01-01

    We compared the incidence of pseudotumours after large head metal-on-metal (MoM) total hip arthroplasty (THA) with that after conventional metal-on-polyethylene (MoP) THA and assessed the predisposing factors to pseudotumour formation. From a previous randomised controlled trial which compared large

  14. Digital tomosynthesis with metal artifact reduction for assessing cementless hip arthroplasty: a diagnostic cohort study of 48 patients

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Hao; Yang, Dejin; Guo, Shengjie; Tang, Jing; Liu, Jian; Wang, Dacheng; Zhou, Yixin [Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Department of Orthopaedic Surgery, Beijing (China)

    2016-11-15

    For postoperative imaging assessment of cementless hip arthroplasty, radiography and computed tomography (CT) were restricted by overlapping structures and metal artifacts, respectively. A new tomosynthesis with metal artifact reduction (TMAR) is introduced by using metal extraction and ordered subset-expectation maximization (OS-EM) reconstruction. This study investigated the effectiveness of TMAR in assessing fixation stability of cementless hip arthroplasty components. We prospectively included 48 consecutive patients scheduled for revision hip arthroplasty in our hospital, with 41 femoral and 35 acetabular cementless components available for evaluation. All patients took the three examinations of radiography, CT, and TMAR preoperatively, with intraoperative mechanical tests, and absence or presence of osteointegration on retrieved prosthesis as reference standards. Three senior surgeons and four junior surgeons evaluated these images independently with uniform criteria. For TMAR, 82 % diagnoses on the femoral side and 84 % diagnoses on the acetabular side were accurate. The corresponding values were 44 and 67 % for radiography, and 39 % and 74 % for CT. Senior surgeons had significantly higher accuracy than junior surgeons by radiography (p < 0.05), but not by TMAR or CT. By minimizing metal artifacts in the bone-implant interface and clearly depicting peri-implant trabecular structures, the TMAR technique improved the diagnostic accuracy of assessing fixation stability of cementless hip arthroplasty, and shortened the learning curve of less experienced surgeons. Level II, diagnostic cohort study. (orig.)

  15. Youth subcultures and problem behaviours in Slovakia : Hip-Hop, Techno-scene, Metal, Punk, Skinheads and Roma

    NARCIS (Netherlands)

    Bobakova, Daniela

    2013-01-01

    Jongeren die deel uitmaken van jeugdsubculturen als hip-hop, techno-scene, metal, punk en skinheads, gebruiken vaker drugs, zijn vaker dronken, spijbelen vaker en beginnen eerder aan seks. Roma-jongeren zijn minder vaak dronken. Dat concludeert Daniela Bobáková op basis van een onderzoek onder deze

  16. Revision of Metal-on-metal Hip Arthroplasty with Well Fixed and Positioned Acetabular Component Using a Dual-mobility Head and Review of Literature.

    Science.gov (United States)

    Figueras, Guillem; Planell, Ramón Vives; Fernàndez, Ramón Serra; Biayna, Joan Camí

    2016-01-01

    As a consequence of use of metal-on-metal hip arthroplasties some patients have precised revision for pain or metal hipersensivity reactions among other causes. We propose to salvage monoblock acetabular component and femoral component using a dual-mobility head and perform a lower morbidity operation in young patients preserving host bone stock in cases with well fixed and positioned components. (1) What clinical problems have been reported in patients with Metal-on-metal hip arthroplasties? (2) Could the tribocorrosion potentially cause a fracture of neck femoral component? (3) Can be the dual-mobility head a recourse in metal-on-metal hip revision? Ten patients were revised for pain or/and raised Cobalt/Chromium levels between August 2012 and December 2015. In three cases femoral neck component was fractured and femoral revision was necessary. In four hips, acetabular and femoral components could be maintained. Age, body index mass, ion levels, acetabular position, size of acetabular component and femoral head, approach, blood transfunsion and time of hospitalization were analized. At a mean follow-up of 25,6 months (6 to 45) the mean postoperative HHS was 92. It was not statistically significant because several patients were low sintomatic before surgery, but had raised Cobalt/Chromium levels in the blood. All patients had near-normal levels of Cobalt/Chromium during the first 6 months after revision surgery. No relevant complications were reported. The use of dual-mobility head can be an acceptable option to revise metal-on-metal arthroplasties correctly oriented with abscence of loosening or infection signs and keeping bone stock in young patients.

  17. Lymphoid Aggregates That Resemble Tertiary Lymphoid Organs Define a Specific Pathological Subset in Metal-on-Metal Hip Replacements

    Science.gov (United States)

    Barone, Francesca; Hardie, Debbie L.; Matharu, Gulraj S.; Davenport, Alison J.; Martin, Richard A.; Grant, Melissa; Mosselmans, Frederick; Pynsent, Paul; Sumathi, Vaiyapuri P.; Addison, Owen; Revell, Peter A.; Buckley, Christopher D.

    2013-01-01

    Aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL) has been used to describe the histological lesion associated with metal-on-metal (M-M) bearings. We tested the hypothesis that the lymphoid aggregates, associated with ALVAL lesions resemble tertiary lymphoid organs (TLOs). Histopathological changes were examined in the periprosthetic tissue of 62 M-M hip replacements requiring revision surgery, with particular emphasis on the characteristics and pattern of the lymphocytic infiltrate. Immunofluorescence and immunohistochemistry were used to study the classical features of TLOs in cases where large organized lymphoid follicles were present. Synchrotron X-ray fluorescence (XRF) measurements were undertaken to detect localisation of implant derived ions/particles within the samples. Based on type of lymphocytic infiltrates, three different categories were recognised; diffuse aggregates (51%), T cell aggregates (20%), and organised lymphoid aggregates (29%). Further investigation of tissues with organised lymphoid aggregates showed that these tissues recapitulate many of the features of TLOs with T cells and B cells organised into discrete areas, the presence of follicular dendritic cells, acquisition of high endothelial venule like phenotype by blood vessels, expression of lymphoid chemokines and the presence of plasma cells. Co-localisation of implant-derived metals with lymphoid aggregates was observed. These findings suggest that in addition to the well described general foreign body reaction mediated by macrophages and a T cell mediated type IV hypersensitivity response, an under-recognized immunological reaction to metal wear debris involving B cells and the formation of tertiary lymphoid organs occurs in a distinct subset of patients with M-M implants. PMID:23723985

  18. Is there added risk in resurfacing a femoral head with cysts?

    Directory of Open Access Journals (Sweden)

    Liu Fei

    2011-10-01

    Full Text Available Abstract Background Femoral head cysts have been identified as a risk factor for early femoral failures after metal-on-metal hip resurfacing arthroplasty (HRA based on limited scientific data. However, we routinely performed HRA if less than 1/3 of the femoral head appeared destroyed by cysts on the preoperative radiograph. This study was undertaken to analyze whether there was an added risk of early femoral failures in HRA when femoral head cysts were present. Methods This retrospective case-control study included 939 MOM HRAs operated by a single surgeon with use of the posterior minimally invasive surgical (MIS approach between November 2005 and January 2009. Patients with all diagnoses except osteonecrosis were included. Among them, 117 HRAs had femoral head cysts ≥ 1 cm identified in surgery. All cysts were treated with bone grafting using acetabular reamings packed into the cavitary defect (instead of filling the cysts with cement. The control group, which had no cyst observed at the time of surgery, was randomly selected from our database using computer algorithms to match those cases in the study group for the parameters of surgical date, age, gender, body mass index, diagnosis, femoral fixation method, and the size of the femoral component. Results The minimum follow-up was 24 months for both groups. The early femoral failure rate in the study group was 3/117 (2.6% and 0/117 in the control group; there was no statistical difference between these two groups (P = 0.08. In the study group, there were two femoral neck fractures (revised: both occurred in patients having a cyst size of 1 cm3; and there was one femoral component loosening at 3-year follow up in a patient having a cyst size of 2 cm3. Conclusion Although the risk of early femoral failures among the group with cysts appeared higher than the group without cysts, we could not demonstrate a significant statistical difference between the two groups. It is possible that bone

  19. Do large heads enhance stability and restore native anatomy in primary total hip arthroplasty?

    Science.gov (United States)

    Lombardi, Adolph V; Skeels, Michael D; Berend, Keith R; Adams, Joanne B; Franchi, Orlando J

    2011-06-01

    Dislocation remains a serious complication in hip arthroplasty. Resurfacing proponents tout anatomic femoral head restoration as an advantage over total hip arthroplasty. However, advances in bearings have expanded prosthetic head options from traditional sizes of 22, 26, 28, and 32 mm to diameters as large as 60 mm. Large heads reportedly enhance stability owing to increased range of motion before impingement and increased jump distance to subluxation. Available larger diameter material combinations include metal- or ceramic-on-highly crosslinked polyethylene and metal-on-metal, each with distinct advantages and disadvantages. We sought to determine (1) if using larger diameter heads has lowered our dislocation rate; and (2) how closely an anatomic metal-on-metal bearing with diameters to 60 mm replicates native femoral head size. We retrospectively reviewed 2020 primary arthroplasties performed with large heads (≥ 36 mm) in 1748 patients and noted dislocation incidence. In a prospective subset of 89 cases using anatomic heads, native femoral head diameter was measured intraoperatively with calipers by an independent observer and later compared with implanted size. One dislocation has occurred in 2020 hips for an incidence of 0.05%. The prosthetic head averaged 0.7 mm larger than the native head with 68 of 89 (76%) reconstructed to within ± 2 mm of native size. Larger diameter heads have contributed to lower dislocation rates and large-diameter metal-on-metal articulation can provide close anatomic restoration in primary THA.

  20. Postoperative Recovery of Mechanical Muscle Function in Hip Replacement Patients

    DEFF Research Database (Denmark)

    Jensen, Carsten; Aagaard, Per; Overgaard, Søren

    2011-01-01

    old hip patients.   MATERIAL AND METHODS Patients: Forty elderly patients (age 55 ± 6, BMI 27.5 ± 4.1) with unilateral osteoarthritis participated in this prospectively study and were randomized to either total or resurfacing hip replacement. All implants inserted by two senior surgeons using only...

  1. Metal artifact reduction software used with abdominopelvic dual-energy CT of patients with metal hip prostheses: assessment of image quality and clinical feasibility.

    Science.gov (United States)

    Han, Seung Chol; Chung, Yong Eun; Lee, Young Han; Park, Kwan Kyu; Kim, Myeong Jin; Kim, Ki Whang

    2014-10-01

    The objective of our study was to determine the feasibility of using Metal Artifact Reduction (MAR) software for abdominopelvic dual-energy CT in patients with metal hip prostheses. This retrospective study included 33 patients (male-female ratio, 19:14; mean age, 63.7 years) who received total hip replacements and 20 patients who did not have metal prostheses as the control group. All of the patients underwent dual-energy CT. The quality of the images reconstructed using the MAR algorithm and of those reconstructed using the standard reconstruction was evaluated in terms of the visibility of the bladder wall, pelvic sidewall, rectal shelf, and bone-prosthesis interface and the overall diagnostic image quality with a 4-point scale. The mean and SD attenuation values in Hounsfield units were measured in the bladder, pelvic sidewall, and rectal shelf. For validation of the MAR interpolation algorithm, pelvis phantoms with small bladder "lesions" and metal hip prostheses were made, and images of the phantoms both with and without MAR reconstruction were evaluated. Image quality was significantly better with MAR reconstruction than without at all sites except the rectal shelf, where the image quality either had not changed or had worsened after MAR reconstruction. The mean attenuation value was changed after MAR reconstruction to its original expected value at the pelvic sidewall (p software with dual-energy CT decreases metal artifacts and increases diagnostic confidence in the assessment of the pelvic cavity but also introduces new artifacts that can obscure pelvic structures.

  2. Comparison and Combination of Dual-Energy- and Iterative-Based Metal Artefact Reduction on Hip Prosthesis and Dental Implants.

    Science.gov (United States)

    Bongers, Malte N; Schabel, Christoph; Thomas, Christoph; Raupach, Rainer; Notohamiprodjo, Mike; Nikolaou, Konstantin; Bamberg, Fabian

    2015-01-01

    To compare and combine dual-energy based and iterative metal artefact reduction on hip prosthesis and dental implants in CT. A total of 46 patients (women:50%,mean age:63±15years) with dental implants or hip prostheses (n = 30/20) were included and examined with a second-generation Dual Source Scanner. 120kV equivalent mixed-images were derived from reconstructions of the 100/Sn140kV source images using no metal artefact reduction (NOMAR) and iterative metal artefact reduction (IMAR). We then generated monoenergetic extrapolations at 130keV from source images without IMAR (DEMAR) or from source images with IMAR, (IMAR+DEMAR). The degree of metal artefact was quantified for NOMAR, IMAR, DEMAR and IMAR+DEMAR using a Fourier-based method and subjectively rated on a five point Likert scale by two independent readers. In subjects with hip prosthesis, DEMAR and IMAR resulted in significantly reduced artefacts compared to standard reconstructions (33% vs. 56%; for DEMAR and IMAR; respectively, pdental implants only IMAR showed a significant reduction of artefacts whereas DEMAR did not (71%, vs. 8% pprosthesis: 47%, dental implants 18%; both pdental implants, compared to a dual energy based method. The combination of DE-source images with IMAR and subsequent monoenergetic extrapolation provides an incremental benefit compared to both single methods.

  3. Reduction of metal artifacts from hip prostheses on CT images of the pelvis: value of iterative reconstructions.

    Science.gov (United States)

    Morsbach, Fabian; Bickelhaupt, Sebastian; Wanner, Guido A; Krauss, Andreas; Schmidt, Bernhard; Alkadhi, Hatem

    2013-07-01

    To assess the value of iterative frequency split-normalized (IFS) metal artifact reduction (MAR) for computed tomography (CT) of hip prostheses. This study had institutional review board and local ethics committee approval. First, a hip phantom with steel and titanium prostheses that had inlays of water, fat, and contrast media in the pelvis was used to optimize the IFS algorithm. Second, 41 consecutive patients with hip prostheses who were undergoing CT were included. Data sets were reconstructed with filtered back projection, the IFS algorithm, and a linear interpolation MAR algorithm. Two blinded, independent readers evaluated axial, coronal, and sagittal CT reformations for overall image quality, image quality of pelvic organs, and assessment of pelvic abnormalities. CT attenuation and image noise were measured. Statistical analysis included the Friedman test, Wilcoxon signed-rank test, and Levene test. Ex vivo experiments demonstrated an optimized IFS algorithm by using a threshold of 2200 HU with four iterations for both steel and titanium prostheses. Measurements of CT attenuation of the inlays were significantly (P algorithm for CT image reconstruction significantly reduces metal artifacts from hip prostheses, improves the reliability of CT number measurements, and improves the confidence for depicting pelvic abnormalities.

  4. Prediction of contact mechanics in metal-on-metal Total Hip Replacement for parametrically comprehensive designs and loads.

    Science.gov (United States)

    Donaldson, Finn E; Nyman, Edward; Coburn, James C

    2015-07-16

    Manufacturers and investigators of Total Hip Replacement (THR) bearings require tools to predict the contact mechanics resulting from diverse design and loading parameters. This study provides contact mechanics solutions for metal-on-metal (MoM) bearings that encompass the current design space and could aid pre-clinical design optimization and evaluation. Stochastic finite element (FE) simulation was used to calculate the head-on-cup contact mechanics for five thousand combinations of design and loading parameters. FE results were used to train a Random Forest (RF) surrogate model to rapidly predict the contact patch dimensions, contact area, pressures and plastic deformations for arbitrary designs and loading. In addition to widely observed polar and edge contact, FE results included ring-polar, asymmetric-polar, and transitional categories which have previously received limited attention. Combinations of design and load parameters associated with each contact category were identified. Polar contact pressures were predicted in the range of 0-200 MPa with no permanent deformation. Edge loading (with subluxation) was associated with pressures greater than 500 MPa and induced permanent deformation in 83% of cases. Transitional-edge contact (with little subluxation) was associated with intermediate pressures and permanent deformation in most cases, indicating that, even with ideal anatomical alignment, bearings may face extreme wear challenges. Surrogate models were able to accurately predict contact mechanics 18,000 times faster than FE analyses. The developed surrogate models enable rapid prediction of MoM bearing contact mechanics across the most comprehensive range of loading and designs to date, and may be useful to those performing bearing design optimization or evaluation. Published by Elsevier Ltd.

  5. Feasibility of asymmetric flow field-flow fractionation coupled to ICP-MS for the characterization of wear metal particles and metalloproteins in biofluids from hip replacement patients

    DEFF Research Database (Denmark)

    Löschner, Katrin; Harrington, Chris F.; Kearney, Jacque-Lucca

    2015-01-01

    Hip replacements are used to improve the quality of life of people with orthopaedic conditions, but the use of metal-on-metal (MoM) arthroplasty has led to poor outcomes for some patients. These problems are related to the generation of micro- to nanosized metal wear particles containing Cr, Co o...

  6. Clinical Results and Serum Metal Ion Concentrations following Ceramic-on-Metal Total Hip Arthroplasty at a Mean Follow-Up of 60 Months

    Science.gov (United States)

    Maurer-Ertl, W.; Pranckh-Matzke, D.; Bratschitsch, G.; Maier, M.

    2017-01-01

    Background. Increased metal ion levels following total hip arthroplasty (THA) with metal-on-metal bearings are a highly debated topic. Local soft tissue reactions with chronic pain and systemic side effects such as neuropathy are described. The aim of the current study was to determine the serum metal ion concentrations of Cobalt (Co) and Chrome (Cr) after THA with a ceramic-on-metal (CoM) bearing. Patients and Methods. Between 2008 and 2010, 20 patients underwent THA using a CoM bearing. Clinical function was evaluated by standardized scores systems (Harris Hip Score and WOMAC Score) and radiological examination included X-rays. Patient's blood samples were obtained for metal ion analysis and correlation analysis was done between these results and implant position. Results. Overall, 13 patients with 14 CoM devices were available for the current series. The mean age at time of surgery was 61 years (range, 41 to 85). The postoperative follow-up ranged from 49 to 68 months (mean, 58). Metal ion determination showed mean concentrations of 3,1 µg/L (range, 0,3–15,2 µg/L) for Co and 1,6 µg/L (range, 0,1–5,5 µg/L) for Cr, respectively. A correlation between cup anteversion and Co and Cr concentrations was shown. Conclusion. The current series showed increments for Co and Cr following CoM THA. However, these levels are lower compared to metal ion concentrations in patients with metal-on-metal bearings and the international accepted threshold for revision of MoM devices. We recommend routine follow-up including at least one obligatory evaluation of serum metal ion concentrations and an MRI once to exclude local soft tissue reactions. PMID:28373980

  7. Jogging after total hip arthroplasty.

    Science.gov (United States)

    Abe, Hirohito; Sakai, Takashi; Nishii, Takashi; Takao, Masaki; Nakamura, Nobuo; Sugano, Nobuhiko

    2014-01-01

    Jogging has been classified as a high-impact sport, and jogging after total hip arthroplasty (THA) has not been well documented. To investigate the participation rate for postoperative jogging as well as jogging parameters and the influence of jogging on implant stability and bearing wear. Case-control study; Level of evidence, 3. Included in this study were 804 hips in 608 patients (85 men, 523 women) who underwent THA between 2005 and 2011 with follow-up longer than 1 year. The mean patient age was 62 years (range, 26-98 years), and mean follow-up duration was 4.8 years (range, 2.3-7.8 years). Hip resurfacing arthroplasty (HRA) was performed in 81 patients and conventional THA in 527 patients. During routine postsurgical visits, patients were given a questionnaire concerning preoperative and postoperative jogging routines. For joggers, frequency, distance, duration, and velocity of jogging were recorded. Patients who did not jog postoperatively were asked to provide reasons for not jogging. Radiographs concerning implant migration and polyethylene wear were evaluated with specialized software, and serum cobalt and chromium ion concentrations were investigated for patients with metal-on-metal articulation. A total of 33 patients (5.4%) performed jogging preoperatively, and 23 patients (3.8%) performed jogging postoperatively. Of the 23 who jogged postoperatively, conventional THA was performed in 13 patients and HRA in 10 patients. Postoperatively, joggers trained a mean of 4 times (range, 1-7 times) per week, covering a mean distance of 3.6 km (range, 0.5-15 km) in a mean time of 29 minutes (range, 5-90 minutes) per session and at a mean speed of 7.7 km/h (range, 3-18 km/h). No patient complained of pain or showed serum cobalt and chromium ion elevation greater than 7 ppb. No hip showed loosening, abnormal component migration, or excessive wear at a mean 5-year follow-up. There were 74 postoperative non-joggers with an interest in jogging. The reasons given for

  8. The increase in cobalt release in metal-on-polyethylene hip bearings in tests with third body abrasives.

    Science.gov (United States)

    de Villiers, Danielle; Traynor, Alison; Collins, Simon N; Shelton, Julia C

    2015-09-01

    Hypersensitivity reactions in patients receiving metal-on-metal hip replacements have been attributed to corrosion products as observed by elevated cobalt and chromium ions in the blood. Although the majority of cases are reported in metal-on-metal, incidences of these reactions have been reported in the metal-on-polyethylene patient population. To date, no in vitro study has considered cobalt release for this bearing combination. This study considered four 28 mm and seven 52 mm diameter metal-on-polyethylene bearings tested following ISO standard hip simulator conditions as well as under established abrasive conditions. These tests showed measurable cobalt in all bearings under standard conditions. Cobalt release, as well as polyethylene wear, increased with diameter, increasing from 52 to 255 ppb. The introduction of bone cement particles into the articulation doubled polyethylene wear and cobalt release while alumina particles produced significant damage on the heads demonstrated by cobalt levels of 70,700 ppb and an increased polyethylene wear from a mean value of 9-160 mm(3)/mc. Cobalt release was indicative of head damage and correlated with polyethylene wear at the next gravimetric interval. The removal of third body particles resulted in continued elevated cobalt levels in the 52 mm diameter bearings tested with alumina compared to standard conditions but the bearings tested with bone cement particles returned to standard levels. The polyethylene wear in the bone cement tested bearings also recovered to standard levels, although the alumina tested bearings continued to wear at a higher rate of 475 mm(3)/mc. Cobalt release was shown to occur in metal-on-polyethylene bearings indicating damage to the metal head resulting in increased polyethylene wear. While large diameter metal-on-polyethylene bearings may provide an increased range of motion and a reduced dislocation risk, increased levels of cobalt are likely to be released and this needs to be fully

  9. Routine patellar resurfacing using an inset patellar technique.

    LENUS (Irish Health Repository)

    Hurson, Conor

    2012-02-01

    The management of the patella in total knee arthroplasty still causes controversy. Whether or not to resurface the patella in primary total knee arthroplasty remains unclear. In this study we examined 220 consecutive total knee replacements, by a single surgeon, where the patella was routinely resurfaced using the inset technique. All patellae were suitable for resurfacing. Patellar thickness was not altered in 54.5% of patellae. In 97.2% the patella was within 2 mm of the original thickness. There were no significant complications. In this study we have found that the inset technique of patella resurfacing in total knee replacement is a simple and safe resurfacing procedure.

  10. Surgical Approach May Influence Survival of Large-Diameter Head Metal-on-Metal Total Hip Arthroplasty: A 6- to 10-Year Follow-Up Study

    Directory of Open Access Journals (Sweden)

    Chih-Chien Hu

    2017-01-01

    Full Text Available Large-diameter head (LDH metal-on-metal (MoM total hip arthroplasty (THA has lost popularity because of metal allergy or ALTRs (adverse local tissue reactions in the past decade. Whether the surgical approach may influence the survival of LDH-MoM-THA has not been reported. From 2006 to 2009, we performed 96 LDH-MoM-THAs on 80 patients using an in situ head-neck assembly technique through a modified Watson-Jones approach. With a mean follow-up of 8.4 years (range, 6.3–10.1 years, the implant survival rate was 100%. All patients were satisfied with the results and the Harris Hip Score improved from 52 points to 98 points. No ALTRs were found, but 17.7% of the 96 hips (17 adverse events experienced adverse events related to the cup, including 5 cases of outlier cup malposition, 11 cases of inadequate cup seating, and 1 acetabular fracture. The tissue tension that was improved by a muscle-sparing approach might lessen the chance of microseparation or edge-loading that is taken as the major risk for early implant failure. Further investigation of whether these LDH-MoM-THAs would fail or not would require a longer follow-up or even retrieval analysis in the future.

  11. Small diameter metal-on-metal total hip arthroplasty at 13 years - a follow-up study.

    Science.gov (United States)

    Tardy, N; Maqdes, A; Boisrenoult, P; Beaufils, P; Oger, P

    2015-12-01

    Theoretically, the properties of second-generation metal-on-metal (MoM) bearings are better for wear, osteolysis and longevity. However, follow-up studies of more than 10 years are rare, in particular with hybrid fixation (cemented stainless steel stems and cementless cup), therefore we evaluated the results of this combination after a mean follow-up of 12.8 years: (1) to analyze the survival rate, (2) to compare it with the survival rate in the same series after 6.4 years (95.8% cup, 94.8% stem), (3) to evaluate clinical and radiographic outcome and (4) to analyze these failures. The number of revisions would increase after 10 years. We evaluated 106 total hip arthroplasties (THA) (Cedior™ press-fit cup with cemented Acora™ (n=50) and Exafit™ (n=56) stems and 28mm Metasul™ bearings performed between January 1999 and December 2002. The survival rate was calculated by the Kaplan-Meier method. The clinical assessment included the Postel Merle d'Aubigné (PMA) and Oxford scores. The radiographic assessment evaluated radiolucencies and osteolysis on standard X-rays. A histological analysis was only performed during revision THA. After a mean 12.8 years of follow-up (10-16), 53 THA were reviewed in 48 patients. Thirteen THA revisions (14%) were performed including 11 aseptic revisions (5 stem fractures, 2 cases of impingement and 3 loosenings [1 bipolar and 3 cups] and one case of osteolysis). Overall survival, taking into account revision for aseptic loosening, was 87.6% (CI 95%=77.3 to 99.3%). The mean PMA and Oxford scores at the final follow-up were 17.6±0.8 points (16-18) and 16.5±5.2 points (12-38) respectively. The radiological follow-up mainly identified radiolucencies around the stem in Gruen zones 1 and 7 (17 and 21% respectively). The survival rate of hybrid MoM THA in this series decreased after 10 years and is lower than studies evaluating cementless THA with the 28-mm Metasul™ bearings (90.9 to 100% survival). Although the clinical results are

  12. The Interchangeability of Plasma and Whole Blood Metal Ion Measurement in the Monitoring of Metal on Metal Hips

    OpenAIRE

    Malek, Ibrahim A.; Rogers, Joanne; King, Amanda Christina; Clutton, Juliet; Winson, Daniel; John, Alun

    2015-01-01

    One hundred and twenty six paired samples of plasma and whole blood were measured with inductively coupled plasma mass spectrometry technique for metal ions analysis to determine a relationship between them. There was a significant difference between the mean plasma and whole blood concentrations of both cobalt (Co) and chromium (Cr) (p < 0.0001 for both Co and Cr). The mean ratio between plasma and whole blood Cr and Co was 1.56 (range: 0.39?3.85) and 1.54 (range: 0.64?18.26), respectively, ...

  13. Metal allergy and second-generation metal-on-metal arthroplasties.

    Science.gov (United States)

    Cousen, Philippa J; Gawkrodger, David J

    2012-02-01

    There are concerns about the induction of metal allergy with second-generation metal-on-metal prostheses, and the role that this may play in the development of complications such as 'pseudotumours' or failure of the implant. In this review, we attempt to set out the current knowledge on this subject. From a review of the literature, it is apparent that the first-generation metal-on-metal replacement hips did cause metal sensitization, and that joint failure was associated with this, although it is still not clear which one led to the other. Highly engineered second-generation metal-on-metal arthroplasties used in joint resurfacings are now increasingly employed. Several studies have recently shown an association between metal sensitization and peri-implant hypersensitivity reactions and implant loosening and failure, although the overall risk appears to be low. The pragmatic approach adopted by most contact dermatologists for patients known to be allergic to nickel, cobalt or chromium and who require joint replacement is to recommend prostheses made of titanium-based alloys. Patch testing continues to be a useful tool as laboratory investigations for metal hypersensitivity continue to emerge. The development of guidelines on the management of patients receiving metal-on-metal arthroplasties suspected of being metal-allergic is desirable. © 2011 John Wiley & Sons A/S.

  14. What Is the Natural History of "Asymptomatic" Pseudotumours in Metal-on-Metal Hip Arthroplasty? Minimum 4-Year Metal Artifact Reduction Sequence Magnetic Resonance Imaging Longitudinal Study.

    Science.gov (United States)

    Kwon, Young-Min; Liow, Ming Han Lincoln; Dimitriou, Dimitris; Tsai, Tsung-Yuan; Freiberg, Andrew A; Rubash, Harry E

    2016-09-01

    Metal Artifact Reduction Sequence Magnetic Resonance Imaging (MARS-MRI) is an important cross-sectional imaging modality in detection of metal-on-metal (MoM) hip arthroplasty (HA) pseudotumours. Potential evolution of pseudotumours detected by MARS-MRI in "asymptomatic" patients with MoMHA arthroplasty beyond 2 years remains largely unknown. The aims of this longitudinal study were to (1) determine the natural history of pseudotumours in "asymptomatic" MoMHA patients under MARS-MRI surveillance and (2) characterize MRI feature(s) associated with progressive pseudotumours. A total of 37 MoMHA (32 patients, mean 56 years old) with pseudotumours on MARS-MRI were evaluated longitudinally using a standardized MARS-MRI protocol. Serum cobalt and chromium levels, pseudotumour size, thickness of the cyst wall, and MRI signal intensity of the abnormality were recorded and analyzed. At minimum of 4-year follow-up (range 49-54 months), 4 Type II pseudotumours (11%) demonstrated MRI evidence of progression. Five Type I pseudotumours (14%) were found to have "regressed." No measurable MRI progression was detected in remaining patients (75%). MRI features associated with progressive pseudotumours included the presence of increased cystic wall thickness and "atypical" mixed fluid signal. MRI pseudotumour progression was not associated with metal ion levels. The natural history of type I cystic pseudotumours continues to be nonprogressive in most "asymptomatic" MoMHA patients at minimum 4 years, suggesting the importance of patient symptoms and MRI characteristic features in the clinical decision-making process. Routine follow-up MARS-MRI evaluation of "asymptomatic" patients with low-grade cystic pseudotumours in the absence of interval clinical changes may not be indicated. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Preoperative Risk Factors Associated With Poor Outcomes of Revision Surgery for "Pseudotumors" in Patients With Metal-on-Metal Hip Arthroplasty.

    Science.gov (United States)

    Liow, Ming Han Lincoln; Dimitriou, Dimitris; Tsai, Tsung-Yuan; Kwon, Young-Min

    2016-12-01

    Revision surgery of failed metal-on-metal (MoM) total hip arthroplasty (THA) for adverse tissue reaction (pseudotumor) can be challenging as a consequence of soft tissue and muscle necrosis. The aims of this study were to (1) report the revision outcomes of patients who underwent revision surgery for failed MoM hip arthroplasty due to symptomatic pseudotumor and (2) identify preoperative risk factors associated with revision outcomes. Between January 2011 and January 2013, a total of 102 consecutive large head MoM hip arthroplasties in 97 patients (male: 62, female: 35), who underwent revision surgery were identified from the database of a multidisciplinary referral center. At minimum follow-up of 2 years (range: 26-52 months), at least one complication had occurred in 14 of 102 revisions (14%). Prerevision radiographic loosening (P = .01), magnetic resonance imaging (MRI) findings of solid lesions with abductor deficiency on MRI (P revision complications. The reoperation rate of revised MoM THA was 7% (7 of 102 hips). Implant survivorship was 88% at 3 years. Metal ion levels declined in most patients after removal of MoM articulation. Revision outcomes of revision surgery for failed MoM THA due to symptomatic pseudotumor demonstrated 14% complication rate and 7% re-revision rate at 30-month follow-up. Our study identified prerevision radiographic loosening, solid lesions/abductor deficiency on MRI, and high grade intraoperative tissue damage as risk factors associated with poorer revision outcomes. This provides clinically useful information for preoperative planning and perioperative counseling of MoM THA patients undergoing revision surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. A case study of radiotherapy planning for a bilateral metal hip prosthesis prostate cancer patient

    International Nuclear Information System (INIS)

    Su, Andy; Reft, Chester; Rash, Carla; Price, Jennifer; Jani, Ashesh B.

    2005-01-01

    The purpose of this report is to communicate the observed advantage of intensity-modulated radiotherapy (IMRT) in a patient with bilateral metallic hip prostheses. In this patient with early-stage low-risk disease, a dose of 74 Gy was planned in two phases-an initial 50 Gy to the prostate and seminal vesicles and an additional 24 Gy to the prostate alone. Each coplanar beam avoided the prosthesis in the beam's eye view. Using the same target expansions for each phase, IMRT and 3D-conformal radiotherapy (CRT) plans were compared for target coverage and inhomogeneity as well as dose to the bladder and rectum. The results of the analysis demonstrated that IMRT provided superior target coverage with reduced dose to normal tissues for both individual phases of the treatment plan as well as for the composite treatment plan. The dose to the rectum was significantly reduced with the IMRT technique, with a composite V80 of 35% for the IMRT plan versus 70% for 3D-CRT plan. Similarly, the dose to the bladder was significantly reduced with a V80 of 9% versus 20%. Overall, various dosimetric parameters revealed the corresponding 3D-CRT plan would not have been acceptable. The results indicate significant success with IMRT in a clinical scenario where there were no curative alternatives for local treatment other than external beam radiotherapy. Therefore, definitive external beam radiation of prostate cancer patients with bilateral prosthesis is made feasible with IMRT. The work described herein may also have applicability to other groups of patients, such as those with gynecological or other pelvic malignancies

  17. Few adverse reactions to metal on metal articulation in total hip arthroplasty in a review study on 358 consecutive cases with 1 to 5 years follow-up

    DEFF Research Database (Denmark)

    Stürup, Jens; Dahl, Line; Jensen, Karl Erik

    2012-01-01

    The aim of the present study was to determine the frequency of adverse reaction to metal on metal total hip arthroplasty using a M2a-38 articulation and a Magnum articulation, (Biomet Warsaw, Indiana).All patients who had received a Metal on Metal bearing prosthesis, in two centres in Copenhagen...... arthroplasty, who had an adverse reaction on one side. In addition the study showed that females had higher values of Co and Cr, and that younger patient reported groin pain more often.The conclusion of this study is that the number of adverse reactions is low, despite the time of observation being relatively...... short, no high frequency of adverse reactions to this prosthesis is expected....

  18. Optimization of scan time in MRI for total hip prostheses. SEMAC tailoring for prosthetic implants containing different types of metals

    Energy Technology Data Exchange (ETDEWEB)

    Deligianni, X. [University of Basel Hospital, Basel (Switzerland). Div. of Radiological Physics; Merian Iselin Klinik, Basel (Switzerland). Inst. of Radiology; Bieri, O. [University of Basel Hospital, Basel (Switzerland). Div. of Radiological Physics; Elke, R. [Orthomerian, Basel (Switzerland); Wischer, T.; Egelhof, T. [Merian Iselin Klinik, Basel (Switzerland). Inst. of Radiology

    2015-12-15

    Magnetic resonance imaging (MRI) of soft tissues after total hip arthroplasty is of clinical interest for the diagnosis of various pathologies that are usually invisible with other imaging modalities. As a result, considerable effort has been put into the development of metal artifact reduction MRI strategies, such as slice encoding for metal artifact correction (SEMAC). Generally, the degree of metal artifact reduction with SEMAC directly relates to the overall time spent for acquisition, but there is no specific consensus about the most efficient sequence setup depending on the implant material. The aim of this article is to suggest material-tailored SEMAC protocol settings. Five of the most common total hip prostheses (1. Revision prosthesis (S-Rom), 2. Titanium alloy, 3. Mueller type (CoNiCRMo alloy), 4. Old Charnley prosthesis (Exeter/Stryker), 5. MS-30 stem (stainless-steel)) were scanned on a 1.5 T MRI clinical scanner with a SEMAC sequence with a range of artifact-resolving slice encoding steps (SES: 2 - 23) along the slice direction (yielding a total variable scan time ranging from 1 to 10 min). The reduction of the artifact volume in comparison with maximal artifact suppression was evaluated both quantitatively and qualitatively in order to establish a recommended number of steps for each case. The number of SES that reduced the artifact volume below approximately 300 mm{sup 3} ranged from 3 to 13, depending on the material. Our results showed that although 3 SES steps can be sufficient for artifact reduction for titanium prostheses, at least 11 SES should be used for prostheses made of materials such as certain alloys of stainless steel. Tailoring SES to the implant material and to the desired degree of metal artifact reduction represents a simple tool for workflow optimization of SEMAC imaging near total hip arthroplasty in a clinical setting.

  19. Optimization of scan time in MRI for total hip prostheses. SEMAC tailoring for prosthetic implants containing different types of metals

    International Nuclear Information System (INIS)

    Deligianni, X.; Wischer, T.; Egelhof, T.

    2015-01-01

    Magnetic resonance imaging (MRI) of soft tissues after total hip arthroplasty is of clinical interest for the diagnosis of various pathologies that are usually invisible with other imaging modalities. As a result, considerable effort has been put into the development of metal artifact reduction MRI strategies, such as slice encoding for metal artifact correction (SEMAC). Generally, the degree of metal artifact reduction with SEMAC directly relates to the overall time spent for acquisition, but there is no specific consensus about the most efficient sequence setup depending on the implant material. The aim of this article is to suggest material-tailored SEMAC protocol settings. Five of the most common total hip prostheses (1. Revision prosthesis (S-Rom), 2. Titanium alloy, 3. Mueller type (CoNiCRMo alloy), 4. Old Charnley prosthesis (Exeter/Stryker), 5. MS-30 stem (stainless-steel)) were scanned on a 1.5 T MRI clinical scanner with a SEMAC sequence with a range of artifact-resolving slice encoding steps (SES: 2 - 23) along the slice direction (yielding a total variable scan time ranging from 1 to 10 min). The reduction of the artifact volume in comparison with maximal artifact suppression was evaluated both quantitatively and qualitatively in order to establish a recommended number of steps for each case. The number of SES that reduced the artifact volume below approximately 300 mm 3 ranged from 3 to 13, depending on the material. Our results showed that although 3 SES steps can be sufficient for artifact reduction for titanium prostheses, at least 11 SES should be used for prostheses made of materials such as certain alloys of stainless steel. Tailoring SES to the implant material and to the desired degree of metal artifact reduction represents a simple tool for workflow optimization of SEMAC imaging near total hip arthroplasty in a clinical setting.

  20. The Interchangeability of Plasma and Whole Blood Metal Ion Measurement in the Monitoring of Metal on Metal Hips

    Directory of Open Access Journals (Sweden)

    Ibrahim A. Malek

    2015-01-01

    Full Text Available One hundred and twenty six paired samples of plasma and whole blood were measured with inductively coupled plasma mass spectrometry technique for metal ions analysis to determine a relationship between them. There was a significant difference between the mean plasma and whole blood concentrations of both cobalt (Co and chromium (Cr (p<0.0001 for both Co and Cr. The mean ratio between plasma and whole blood Cr and Co was 1.56 (range: 0.39–3.85 and 1.54 (range: 0.64–18.26, respectively, but Bland and Altman analysis illustrated that this relationship was not universal throughout the range of concentrations. There was higher variability at high concentrations for both ions. We conclude that both these concentrations should not be used interchangeably and conversion factors are unreliable due to concentration dependent variability.

  1. No association between pseudotumors, high serum metal-ion levels and metal hypersensitivity in large-head metal-on-metal total hip arthroplasty at 5-7-year follow-up

    DEFF Research Database (Denmark)

    Hjorth, Mette Holm; Stilling, Maiken; Soballe, Kjeld

    2016-01-01

    (THA) and to investigate its relationship to serum metal-ion levels and hypersensitivity to metal. METHODS: Forty-one patients (31 males), mean age 52 (28-68) years, with a total of 49 large-head MoM THA participated in a 5-7-year follow-up study. Patients underwent ultrasonography, serum metal-ion...... concentrations were measured, metal allergy and atopic dermatitis were evaluated, and the questionnaires of the Oxford Hip Score (OHS), Harris Hip Score (HHS) and the Short-Form Health Survey (SF-36) were completed. RESULTS: Pseudotumors were found in eight patients, but they were asymptomatic and their serum...... metal-ion levels were similar to those observed in patients with no pseudotumors (p > 0.36). The capsule-stem distance of mean 8.6 mm (SD 3.82, 95% CI: 5.40-11.79) was wider (p = 0.02) in patients with pseudotumours than in patients without pseudotumors of mean 5.6 mm (SD 2.89, 95% CI: 4...

  2. Adverse reaction to metal debris in a patient with acetabular shell loosening 8 years after ceramic-on-metal total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Benjamin R. Pulley, MD

    2015-12-01

    Full Text Available A 41-year-old woman presented 8 years after a left total hip arthroplasty. She complained of progressive groin pain for several months. Radiographs demonstrated a hard-on-hard bearing surface combination and radiolucent lines surrounding the acetabular shell. Laboratory analysis revealed a mild leukocytosis, a normal erythrocyte sedimentation rate, and a mildly elevated C-reactive protein. Serum cobalt and chromium levels were markedly elevated. Aspiration of the hip joint was negative for infection. Magnetic resonance imaging failed to demonstrate a pseudotumor. Revision total hip arthroplasty was performed, and a ceramic-on-metal bearing surface combination was explanted. Significant intraoperative findings included dark gray synovial fluid, metal transfer onto the ceramic femoral head, and a grossly loose acetabular shell pivoting about a single well-fixed screw. The explanted components otherwise appeared normal macroscopically. Histologic analysis of the capsular tissue demonstrated aseptic lymphocyte-dominated vasculitis-associated lesion and inclusion bodies consistent with third-body wear. Revision arthroplasty to a ceramic-on-polyethylene bearing surface combination was performed with a good clinical result and laboratory normalization at 9-month follow-up.

  3. Comparison of metal ion concentrations and implant survival after total hip arthroplasty with metal-on-metal versus metal-on-polyethylene articulations

    OpenAIRE

    Dahlstrand, Henrik; Stark, André; Wick, Marius C; Anissian, Lucas; Hailer, Nils P; Weiss, Rüdiger J

    2017-01-01

    Background and purpose Large metal-on-metal (MoM) articulations are associated with metal wear and corrosion, leading to increased metal ion concentrations and unacceptable revision rates. There are few comparative studies of 28-mm MoM articulations with conventional metal-on-polyethylene (MoP) couplings. We present a long-term follow-up of a randomized controlled trial comparing MoM versus MoP 28-mm articulations, focused on metal ions and implant survival. Patients and methods 85 patients w...

  4. CO2 laser resurfacing of the face and neck.

    Science.gov (United States)

    Goldman, M P

    2001-05-01

    Laser resurfacing with the short-pulsed, high-energy CO2 laser has been used to treat photodamaged skin and acne scars. Efficacy and safety have been demonstrated with this technique since 1992. Newer treatment methods, including sequential or combination treatment with the Er:YAG laser have led to increased efficacy with a decrease in adverse sequelae. This article details the author's experience with CO2 laser resurfacing and promotes the use of sequential CO2/Er:YAG laser resurfacing.

  5. Evaluation of the fixation of the trabecular metal wedge in patients undergoing revision of total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Victor Magalhães Callado

    2014-08-01

    Full Text Available Objective:this study aimed to evaluate the fixation of the trabecular metal wedge in patients undergoing revision of total hip arthroplasty.Methods:twenty-three cases with minimum grading of Paprosky II-B that were operated between July 2008 and February 2013 were evaluated. These cases were evaluated based on radiographs before the operation, immediately after the operation and later on after the operation. Loss of fixation was defined as a change in the abduction angle of the component greater than 10° or any mobilization greater than 6 mm.Results:it was found that there was 100% fixation of the acetabula after a mean of 29.5 months. One case underwent removal of the implanted components due to infection.Conclusions:there is still no consensus regarding the best option for reconstructing hips with bone loss. However, revision using a trabecular metal wedge has presented excellent short-and medium-term results. This qualifies it as an important tool for achieving a fixed and stable acetabular component.

  6. Total hip arthroplasty survival in femoral head avascular necrosis versus primary hip osteoarthritis: Case-control study with a mean 10-year follow-up after anatomical cementless metal-on-metal 28-mm replacement.

    Science.gov (United States)

    Ancelin, D; Reina, N; Cavaignac, E; Delclaux, S; Chiron, P

    2016-12-01

    Total hip arthroplasty is the most widely used procedure to treat avascular necrosis (AVN) of the femoral head. Few studies have compared the outcomes of THA in femoral head AVN and primary hip osteoarthritis. Therefore we performed a case-control study to compare THA for femoral head AVN vs. primary hip osteoarthritis in terms of: (1) prosthesis survival, (2) complication rates, (3) functional outcomes and radiographic outcomes, (4) and to determine whether specific risk factors for THA failure exist in femoral head AVN. THA survival is similar in femoral head AVN and primary hip osteoarthritis. We compared two prospective cohorts of patients who underwent THA before 65 years of age, one composed of cases with femoral head AVN and the other of controls with primary hip osteoarthritis. In both cohorts, a cementless metal-on-metal prosthesis with a 28-mm cup and an anatomical stem was used. Exclusion criteria were THA with other types of prosthesis, posttraumatic AVN, and secondary osteoarthritis. With α set at 5%, to obtain 80% power, 246 patients were required in all. Prosthesis survival was assessed based on time to major revision (defined as replacement of at least one implant fixed to bone) and time to aseptic loosening. The other evaluation criteria were complications, Postel-Merle d'Aubigné (PMA) score, and the Engh and Agora Radiographic Assessment (ARA) scores for implant osseointegration. The study included 282 patients, 149 with AVN and 133 with osteoarthritis. Mean age was 47.8±10.2 years (range, 18.5-65) and mean follow-up was 11.4±2.8 years (range, 4.5-18.3 years). The 10-year survival rates were similar in the two groups: for major revision, AVN group, 92.5% (95% confidence interval [95% CI], 90.2-94.8) and osteoarthritis group, 95.3% (95% CI, 92.9-97.7); for aseptic loosening, AVN group, 98.6% (95% CI, 97.6-98.6) and osteoarthritis, 99.2% (95% CI, 98.4-100). The AVN group had higher numbers of revision for any reason (19 vs. 6, P=0.018) and

  7. Feasibility of asymmetric flow field-flow fractionation coupled to ICP-MS for the characterization of wear metal particles and metalloproteins in biofluids from hip replacement patients.

    Science.gov (United States)

    Loeschner, Katrin; Harrington, Chris F; Kearney, Jacque-Lucca; Langton, David J; Larsen, Erik H

    2015-06-01

    Hip replacements are used to improve the quality of life of people with orthopaedic conditions, but the use of metal-on-metal (MoM) arthroplasty has led to poor outcomes for some patients. These problems are related to the generation of micro- to nanosized metal wear particles containing Cr, Co or other elements, but the current analytical methods used to investigate the processes involved do not provide sufficient information to understand the size or composition of the wear particles generated in vivo. In this qualitative feasibility study, asymmetric flow field-flow fractionation (AF(4)) coupled with inductively coupled plasma mass spectrometry (ICP-MS) was used to investigate metal protein binding and the size and composition of wear metal particles present in serum and hip aspirates from MoM hip replacement patients. A well-established HPLC anion exchange chromatography (AEC) separation system coupled to ICP-MS was used to confirm the metal-protein associations in the serum samples. Off-line single particle ICP-MS (spICP-MS) analysis was used to confirm the approximate size distribution indicated by AF(4) of the wear particles in hip aspirates. In the serum samples, AF(4) -ICP-MS suggested that Cr was associated with transferrin (Tf) and Co with albumin (Alb) and an unidentified species; AEC-ICP-MS confirmed these associations and also indicated an association of Cr with Alb. In the hip aspirate sample, AF(4)-ICP-MS suggested that Cr was associated with Alb and Tf and that Co was associated with Alb and two unidentified compounds; AEC analysis confirmed the Cr results and the association of Co with Alb and a second compound. Enzymatic digestion of the hip aspirate sample, followed by separation using AF(4) with detection by UV absorption (280 nm), multi-angle light scattering and ICP-MS, suggested that the sizes of the Cr-, Co- and Mo-containing wear particles in a hip aspirate sample were in the range 40-150 nm. Off-line spICP-MS was used to confirm these

  8. Local tissue reaction and necrosis-induced femoral nerve palsy in a patient with a metal-on-metal total hip arthroplasty: a case report.

    Science.gov (United States)

    Wodowski, Andrew J; Rider, Carson M; Mihalko, William M

    2014-01-01

    This case report describes a 54-year-old Hispanic male who developed femoral nerve palsy approximately 1 year after metal-on-metal total hip arthroplasty (MOM THA). Cobalt and chromium levels were 4.8 ppb and undetectable, respectively. MRI demonstrated a well-encapsulated pseudotumor that communicated with the anterior portion of the right hip, and EMG showed neuropraxic femoral nerve injury. As a result, the patient experienced motor and sensory loss in the femoral and proximal saphenous nerve distributions. Surgical revision to ceramic-on-poly THA with debridement and decompression of the pseudotumor improved the patient's neurological status. Similar acute local tissue reactions have been described but the serum levels of cobalt and chrome associated with these reactions have been variable. Wear particles and products produced from corrosion at the head taper junction from MOM THA can potentially lead to cellular dysfunction with subsequent pseudotumer formation, but these reactions and fluid collections have also been found. In this patient, serum cobalt levels were elevated, while serum chromium levels remained undetectable. The purpose of this case report is to describe one patient's response and to review the recent literature regarding potential complications of MOM THA.

  9. Block-step asymmetry 5 years after large-head metal-on-metal total hip arthroplasty is related to lower muscle mass and leg power on the implant side.

    Science.gov (United States)

    Hjorth, M H; Stilling, M; Lorenzen, N D; Jakobsen, S S; Soballe, K; Mechlenburg, I

    2014-06-01

    Metal-on-metal articulations mimic the human hip anatomy, presumably lower dislocation rates and increase the range-of-motion. This study aims to measure the muscle mass and power of both legs in patients with unilateral metal-on-metal total hip arthroplasty, and to investigate their effect on block-step test, spatio-temporal gait parameters and self-reported function. Twenty-eight patients (7 women), mean age 50 (28-68) years, participated in a 5-7 year follow-up. Patients had received one type unilateral large-head metal-on-metal total hip articulation, all of which were well-functioning at follow-up. Mean muscle mass was measured by the total-body Dual energy X-ray Absorption scans, and muscle power was measured in a leg extensor power rig. Block-step test and spatio-temporal gait parameters were measured with an inertial measurement unit. Self-reported function was assessed by the Hip Disability and Osteoarthritis Outcome Score. We found a significant difference between the mean muscle mass of the implant-side leg and the non-implant-side leg in hip, thigh and calf areas (Ppower (P=0.025). Correlations between mean muscle mass and mean muscle power were significant for both the implant-side leg (r=0.45, P=0.018) and the non-implant-side leg (r=0.51, P=0.007). The difference in mean muscle power between legs correlated with block-step test asymmetry during ascending (r=0.40, P=0.047) and descending (r=0.53, P=0.006). Correlations between self-reported function and power of the implant-side leg were not significant. Young patients have not fully regained muscle mass, muscle power and function 5-7 years after metal-on-metal total hip arthroplasty. Copyright © 2014. Published by Elsevier Ltd.

  10. Results of Equilibrium Resurfacing Monta Carlo Models on Venus

    Science.gov (United States)

    Bjonnes, E. E.; Hansen, V. L.; Swenson, J. B.

    2008-03-01

    Previous equilibrium resurfacing tests failed to include increments between 10 and 0.03%. We tested this parameter space and found that there is no statistical evidence that equilibrium resurfacing cannot meet the two key observations of Venus' impact crater data set.

  11. Choice of implant combinations in total hip replacement: systematic review and network meta-analysis.

    Science.gov (United States)

    López-López, José A; Humphriss, Rachel L; Beswick, Andrew D; Thom, Howard H Z; Hunt, Linda P; Burston, Amanda; Fawsitt, Christopher G; Hollingworth, William; Higgins, Julian P T; Welton, Nicky J; Blom, Ashley W; Marques, Elsa M R

    2017-11-02

    Objective  To compare the survival of different implant combinations for primary total hip replacement (THR). Design  Systematic review and network meta-analysis. Data sources  Medline, Embase, The Cochrane Library, ClinicalTrials.gov, WHO International Clinical Trials Registry Platform, and the EU Clinical Trials Register. Review methods  Published randomised controlled trials comparing different implant combinations. Implant combinations were defined by bearing surface materials (metal-on-polyethylene, ceramic-on-polyethylene, ceramic-on-ceramic, or metal-on-metal), head size (large ≥36 mm or small meta-analysis for revision. There was no evidence that the risk of revision surgery was reduced by other implant combinations compared with the reference implant combination. Although estimates are imprecise, metal-on-metal, small head, cemented implants (hazard ratio 4.4, 95% credible interval 1.6 to 16.6) and resurfacing (12.1, 2.1 to 120.3) increase the risk of revision at 0-2 years after primary THR compared with the reference implant combination. Similar results were observed for the 2-10 years period. 31 studies (2888 patients) were included in the analysis of Harris hip score. No implant combination had a better score than the reference implant combination. Conclusions  Newer implant combinations were not found to be better than the reference implant combination (metal-on-polyethylene (not highly cross linked), small head, cemented) in terms of risk of revision surgery or Harris hip score. Metal-on-metal, small head, cemented implants and resurfacing increased the risk of revision surgery compared with the reference implant combination. The results were consistent with observational evidence and were replicated in sensitivity analysis but were limited by poor reporting across studies. Systematic review registration  PROSPERO CRD42015019435. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence

  12. Laser systems for ablative fractional resurfacing

    DEFF Research Database (Denmark)

    Paasch, Uwe; Haedersdal, Merete

    2011-01-01

    Ablative fractional resurfacing (AFR) creates microscopic vertical ablated channels that are surrounded by a thin layer of coagulated tissue, constituting the microscopic treatment zones (MTZs). AFR induces epidermal and dermal remodeling, which raises new possibilities for the treatment...... of a variety of skin conditions, primarily chronically photodamaged skin, but also acne and burn scars. In addition, it is anticipated that AFR can be utilized in the laser-assisted delivery of topical drugs. Clinical efficacy coupled with minimal downtime has driven the development of various fractional...

  13. The effect of metal artefact reduction on CT-based attenuation correction for PET imaging in the vicinity of metallic hip implants. A phantom study

    International Nuclear Information System (INIS)

    Harnish, R.; Lang, T.F.; Prevrhal, S.; Alavi, A.; Zaidi, H.

    2014-01-01

    To determine if metal artefact reduction (MAR) combined with a priori knowledge of prosthesis material composition can be applied to obtain CT-based attenuation maps with sufficient accuracy for quantitative assessment of 18 F-fluorodeoxyglucose uptake in lesions near metallic prostheses. A custom hip prosthesis phantom with a lesion-sized cavity filled with 0.2 ml 18 F-FDG solution having an activity of 3.367 MBq adjacent to a prosthesis bore was imaged twice with a chrome-cobalt steel hip prosthesis and a plastic replica, respectively. Scanning was performed on a clinical hybrid PET/CT system equipped with an additional external 137 Cs transmission source. PET emission images were reconstructed from both phantom configurations with CT-based attenuation correction (CTAC) and with CT-based attenuation correction using MAR (MARCTAC). To compare results with the attenuation-correction method extant prior to the advent of PET/CT, we also carried out attenuation correction with 137 Cs transmission-based attenuation correction (TXAC). CTAC and MARCTAC images were scaled to attenuation coefficients at 511 keV using a trilinear function that mapped the highest CT values to the prosthesis alloy attenuation coefficient. Accuracy and spatial distribution of the lesion activity was compared between the three reconstruction schemes. Compared to the reference activity of 3.37 MBq, the estimated activity quantified from the PET image corrected by TXAC was 3.41 MBq. The activity estimated from PET images corrected by MARCTAC was similar in accuracy at 3.32 MBq. CTAC corrected PET images resulted in nearly 40% overestimation of lesion activity at 4.70 MBq. Comparison of PET images obtained with the plastic and metal prostheses in place showed that CTAC resulted in a marked distortion of the 18 F-FDG distribution within the lesion, whereas application of MARCTAC and TXAC resulted in lesion distributions similar to those observed with the plastic replica. (author)

  14. Evaluation of metal artifacts in clinical MR images of patients with total hip arthroplasty using different metal artifact-reducing sequences.

    Science.gov (United States)

    Müller, Gunilla M; Lundin, Björn; von Schewelov, Thord; Müller, Markus F; Ekberg, Olle; Månsson, Sven

    2015-03-01

    To evaluate the distortion and artifact area of metal in MR images and to compare artifact reduction using different metal artifact-reducing sequences in patients with metal-on-metal (MoM) and non-MoM total hip prostheses. Thirty-six MoM and 15 non-MoM prostheses were examined in a 1.5-T MR scanner using T1-weighted (T1-w) sequences: turbo spin echo (TSE) high-readout bandwidth (hiBW), T1-w; TSE view angle tilting (VAT), T1-w; TSE VAT + slice encoding for metal artifact correction (SEMAC); short tau inversion recovery (STIR) hiBW or matched RF pulses (mRFp). Distortion was quantified using a new method measuring the acetabular roof angle (ARA). The artifact area was defined in the mid-coronal plane of the artifact. The T1 VAT + SEMAC sequence showed the least distortion compared to T1 VAT and T1-hiBW (150°, 127° and 102°, p < 0.001, in MoM; 152°, 143° and 128°, p ≤ 0.014, in non-MoM). The artifact area was smaller in MoM prostheses using the T1 VAT sequence compared to T1 hiBW and T1 VAT + SEMAC (2506 mm(2), 3160 mm(2) and 3214 mm(2), p < 0.001) and smaller in non-MoM prostheses using T1 VAT compared to T1-hiBW (4296 mm(2) and 4831 mm(2), p = 0.041). STIR-mRFp substantially reduced the artifact size compared with STIR-hiBW (MoM 4559 mm(2) and 6323 mm(2); non-MoM 5625 mm(2) and 8764 mm(2), p < 0.001). Metal artifacts in MR imaging examinations of hip prostheses can be evaluated for distortion using a distortion angle (ARA) and the degree of signal artifact as determined by measuring the largest cross-sectional artifact area. T1 VAT + SEMAC showed the least distortion; T1 VAT and STIR-mRFp were most efficient for reduction of the artifact area.

  15. Fretting and Corrosion Between a Metal Shell and Metal Liner May Explain the High Rate of Failure of R3 Modular Metal-on-Metal Hips.

    Science.gov (United States)

    Ilo, Kevin C; Derby, Emma J; Whittaker, Robert K; Blunn, Gordon W; Skinner, John A; Hart, Alister J

    2017-05-01

    The R3 acetabular system used with its metal liner has higher revision rates when compared to its ceramic and polyethylene liner. In June 2012, the medical and healthcare products regulatory agency issued an alert regarding the metal liner of the R3 acetabular system. Six retrieved R3 acetabular systems with metal liners underwent detailed visual analysis using macroscopic and microscopic techniques. Visual analysis discovered corrosion on the backside of the metal liners. There was a distinct border to the areas of corrosion that conformed to antirotation tab insertions on the inner surface of the acetabular shell, which are for the polyethylene liner. Scanning electron microscopy indicated evidence of crevice corrosion, and energy-dispersive X-ray analysis confirmed corrosion debris rich in titanium. The high failure rate of the metal liner option of the R3 acetabular system may be attributed to corrosion on the backside of the liner which appear to result from geometry and design characteristics of the acetabular shell. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Current Status of Fractional Laser Resurfacing.

    Science.gov (United States)

    Carniol, Paul J; Hamilton, Mark M; Carniol, Eric T

    2015-01-01

    Fractional lasers were first developed based on observations of lasers designed for hair transplantation. In 2007, ablative fractional laser resurfacing was introduced. The fractionation allowed deeper tissue penetration, leading to greater tissue contraction, collagen production and tissue remodeling. Since then, fractional erbium:YAG resurfacing lasers have also been introduced. These lasers have yielded excellent results in treating photoaging, acne scarring, and dyschromia. With the adjustment of microspot density, pulse duration, number of passes, and fluence, the surgeon can adjust the treatment effects. These lasers have allowed surgeons to treat patients with higher Fitzpatrick skin types (types IV to VI) and greater individualize treatments to various facial subunits. Immunohistochemical analysis has demonstrated remodeling effects of the tissues for several months, producing longer lasting results. Adjuvant treatments are also under investigation, including concomitant face-lift, product deposition, and platelet-rich plasma. Finally, there is a short recovery time from treatment with these lasers, allowing patients to resume regular activities more quickly. Although there is a relatively high safety profile for ablative fractionated lasers, surgeons should be aware of the limitations of specific treatments and the associated risks and complications.

  17. Surface chemistry and microstructure of metallic biomaterials for hip and knee endoprostheses

    Science.gov (United States)

    Jenko, Monika; Gorenšek, Matevž; Godec, Matjaž; Hodnik, Maxinne; Batič, Barbara Šetina; Donik, Črtomir; Grant, John T.; Dolinar, Drago

    2018-01-01

    The surface chemistry and microstructures of titanium alloys (both new and used) and CoCrMo alloys used for hip and knee endoprostheses were determined using SEM (morphology), EBSD (phase analysis), AES and XPS (surface chemistry). Two new and two used endoprostheses were studied. The SEM SE and BE images showed their microstructures, while the EBSD provided the phases of the materials. During the production of the hip and knee endoprostheses, these materials are subject to severe thermomechanical treatments and physicochemical processes that are decisive for CoCrMo alloys. The AES and XPS results showed that thin oxide films on (a) Ti6Al4V are primarily a mixture of TiO2 with a small amount of Al2O3, while the V is depleted, (b) Ti6Al7Nb is primarily a mixture of TiO2 with a small amount of Al2O3 and Nb2O5, and (c) the CoCrMo alloy is primarily a mixture of Cr2O3 with small amounts of Co and Mo oxides. The thin oxide film on the CoCrMo alloy should prevent intergranular corrosion and improve the biocompatibility. The thin oxide films on the Ti alloys prevent further corrosion, improve the biocompatibility, and affect the osseointegration.

  18. Grading the severity of soft tissue changes associated with metal-on-metal hip replacements: reliability of an MR grading system

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Helen; Cahir, John G.; Goodwin, Richard W. [Norfolk and Norwich University Hospital, Department of Radiology, Norwich, Norfolk (United Kingdom); Toms, Andoni Paul [Norfolk and Norwich University Hospital, Department of Radiology, Norwich, Norfolk (United Kingdom); Norwich Radiology Academy, Norwich (United Kingdom); Wimhurst, James; Nolan, John F. [Norfolk and Norwich University Hospital, Department of Orthopaedics, Norwich, Norfolk (United Kingdom)

    2011-03-15

    Metal-on-metal (MoM) soft tissue reactions or aseptic lymphocytic vasculitis-associated lesions (ALVAL) are being recognised using metal artefact reduction (MAR) MR with increasing frequency following the advent of second generation metal-on-metal bearings, but there is no standardised technique for reporting of MR appearances in this disease. The aim of this study was to measure the reliability of a grading system designed for scoring the severity of MoM disease on MRI. MRI examinations of 73 hips in 59 patients were retrospectively selected and then anonymised, randomised and reviewed by three independent observers (musculoskeletal radiologists). Each MR examination was scored as either A: normal, B: infection, C1: mild MoM disease, C2: moderate MoM disease or C3: severe MoM disease according to pre-defined criteria. Kappa correlation statistics were used to compare the observations. There was substantial agreement among all three observers; the correlation coefficient between the two most experienced observers was {kappa} = 0.78 [95% confidence intervals (CI): 0.68-0.88] and when compared with the least experienced observer coefficients were {kappa} = 0.69 (95% CI: 0.57-0.80) and {kappa} = 0.66 (95% CI: 0.54-0.78). The strongest correlation occurred for grades A, C2 and C3. The weakest correlations occurred for grades B and C1. The grading system described in this study is reliable for evaluating ALVAL in MoM prostheses using MR but is limited in differentiating mild disease from infection. (orig.)

  19. Plumes as a Mechanism for Equilibrium Resurfacing of Venus

    Science.gov (United States)

    Hansen, V. L.; Young, D. A.

    2004-03-01

    End member hypotheses catastrophic- and equilibrium-volcanic-resurfacing fall short in addressing Venus' crater database, and both assume crater removal by burial. We propose an alternative hypothesis that includes crater destruction by annealing.

  20. The effect of metal artefact reduction on CT-based attenuation correction for PET imaging in the vicinity of metallic hip implants: a phantom study.

    Science.gov (United States)

    Harnish, Roy; Prevrhal, Sven; Alavi, Abass; Zaidi, Habib; Lang, Thomas F

    2014-07-01

    To determine if metal artefact reduction (MAR) combined with a priori knowledge of prosthesis material composition can be applied to obtain CT-based attenuation maps with sufficient accuracy for quantitative assessment of (18)F-fluorodeoxyglucose uptake in lesions near metallic prostheses. A custom hip prosthesis phantom with a lesion-sized cavity filled with 0.2 ml (18)F-FDG solution having an activity of 3.367 MBq adjacent to a prosthesis bore was imaged twice with a chrome-cobalt steel hip prosthesis and a plastic replica, respectively. Scanning was performed on a clinical hybrid PET/CT system equipped with an additional external (137)Cs transmission source. PET emission images were reconstructed from both phantom configurations with CT-based attenuation correction (CTAC) and with CT-based attenuation correction using MAR (MARCTAC). To compare results with the attenuation-correction method extant prior to the advent of PET/CT, we also carried out attenuation correction with (137)Cs transmission-based attenuation correction (TXAC). CTAC and MARCTAC images were scaled to attenuation coefficients at 511 keV using a trilinear function that mapped the highest CT values to the prosthesis alloy attenuation coefficient. Accuracy and spatial distribution of the lesion activity was compared between the three reconstruction schemes. Compared to the reference activity of 3.37 MBq, the estimated activity quantified from the PET image corrected by TXAC was 3.41 MBq. The activity estimated from PET images corrected by MARCTAC was similar in accuracy at 3.32 MBq. CTAC corrected PET images resulted in nearly 40 % overestimation of lesion activity at 4.70 MBq. Comparison of PET images obtained with the plastic and metal prostheses in place showed that CTAC resulted in a marked distortion of the (18)F-FDG distribution within the lesion, whereas application of MARCTAC and TXAC resulted in lesion distributions similar to those observed with the plastic replica. MAR combined

  1. Technical note: Comparison of metal-on-metal hip simulator wear measured by gravimetric, CMM and optical profiling methods

    Science.gov (United States)

    Alberts, L. Russell; Martinez-Nogues, Vanesa; Baker Cook, Richard; Maul, Christian; Bills, Paul; Racasan, R.; Stolz, Martin; Wood, Robert J. K.

    2018-03-01

    Simulation of wear in artificial joint implants is critical for evaluating implant designs and materials. Traditional protocols employ the gravimetric method to determine the loss of material by measuring the weight of the implant components before and after various test intervals and after the completed test. However, the gravimetric method cannot identify the location, area coverage or maximum depth of the wear and it has difficulties with proportionally small weight changes in relatively heavy implants. In this study, we compare the gravimetric method with two geometric surface methods; an optical light method (RedLux) and a coordinate measuring method (CMM). We tested ten Adept hips in a simulator for 2 million cycles (MC). Gravimetric and optical methods were performed at 0.33, 0.66, 1.00, 1.33 and 2 MC. CMM measurements were done before and after the test. A high correlation was found between the gravimetric and optical methods for both heads (R 2  =  0.997) and for cups (R 2  =  0.96). Both geometric methods (optical and CMM) measured more volume loss than the gravimetric method (for the heads, p  =  0.004 (optical) and p  =  0.08 (CMM); for the cups p  =  0.01 (optical) and p  =  0.003 (CMM)). Two cups recorded negative wear at 2 MC by the gravimetric method but none did by either the optical method or by CMM. The geometric methods were prone to confounding factors such as surface deformation and the gravimetric method could be confounded by protein absorption and backside wear. Both of the geometric methods were able to show the location, area covered and depth of the wear on the bearing surfaces, and track their changes during the test run; providing significant advantages to solely using the gravimetric method.

  2. Quantifying metal artefact reduction using virtual monochromatic dual-layer detector spectral CT imaging in unilateral and bilateral total hip prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Wellenberg, R.H.H., E-mail: r.h.wellenberg@amc.uva.nl [Department of Radiology, Academic Medical Centre, Amsterdam (Netherlands); Boomsma, M.F., E-mail: m.f.boomsma@isala.nl [Department of Radiology, Isala, Zwolle (Netherlands); Osch, J.A.C. van, E-mail: j.a.c.van.osch@isala.nl [Department of Radiology, Isala, Zwolle (Netherlands); Vlassenbroek, A., E-mail: alain.vlassenbroek@philips.com [Philips Medical Systems, Brussels (Belgium); Milles, J., E-mail: julien.milles@philips.com [Philips Medical Systems, Eindhoven (Netherlands); Edens, M.A., E-mail: m.a.edens@isala.nl [Department of Innovation and Science, Isala, Zwolle (Netherlands); Streekstra, G.J., E-mail: g.j.streekstra@amc.uva.nl [Department of Radiology, Academic Medical Centre, Amsterdam (Netherlands); Slump, C.H., E-mail: c.h.slump@utwente.nl [MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede (Netherlands); Maas, M., E-mail: m.maas@amc.uva.nl [Department of Radiology, Academic Medical Centre, Amsterdam (Netherlands)

    2017-03-15

    Highlights: • Dual-layer detector CT reduces metal artefacts at high monochromatic energies (keV). • 130 keV images were optimal based on quantitative analysis on CNRs. • Optimal keVs varied from 74 to 150 keV for different hip prostheses configurations. • The Titanium alloy resulted in less severe artefacts compared to the Cobalt alloy. • Severe metal artefacts, caused by extensive photon-starvation, were not reduced. - Abstract: Purpose: To quantify the impact of prosthesis material and design on the reduction of metal artefacts in total hip arthroplasties using virtual monochromatic dual-layer detector Spectral CT imaging. Methods: The water-filled total hip arthroplasty phantom was scanned on a novel 128-slice Philips IQon dual-layer detector Spectral CT scanner at 120-kVp and 140-kVp at a standard computed tomography dose index of 20.0 mGy. Several unilateral and bilateral hip prostheses consisting of different metal alloys were inserted and combined which were surrounded by 18 hydroxyapatite calcium carbonate pellets representing bone. Images were reconstructed with iterative reconstruction and analysed at monochromatic energies ranging from 40 to 200 keV. CT numbers in Hounsfield Units (HU), noise measured as the standard deviation in HU, signal-to-noise-ratios (SNRs) and contrast-to-noise-ratios (CNRs) were analysed within fixed regions-of-interests placed in and around the pellets. Results: In 70 and 74 keV virtual monochromatic images the CT numbers of the pellets were similar to 120-kVp and 140-kVp polychromatic results, therefore serving as reference. A separation into three categories of metal artefacts was made (no, mild/moderate and severe) where pellets were categorized based on HU deviations. At high keV values overall image contrast was reduced. For mild/moderate artefacts, the highest average CNRs were attained with virtual monochromatic 130 keV images, acquired at 140-kVp. Severe metal artefacts were not reduced. In 130 keV images

  3. Systemic and local toxicity of metal debris released from hip prostheses: A review of experimental approaches.

    Science.gov (United States)

    Bijukumar, Divya Rani; Segu, Abhijith; Souza, Júlio C M; Li, XueJun; Barba, Mark; Mercuri, Louis G; J Jacobs, Joshua; Mathew, Mathew Thoppil

    2018-01-12

    Despite the technological improvements in orthopedic joint replacement implants, wear and corrosion products associated with the metal components of these implants may result in adverse local tissue and perhaps systemic reactions and toxicities. The current review encompasses a literature review of the local and systemic toxicity studies concerning the effect of CoCrMo wear debris released from wear and corrosion of orthopedic implants and prostheses. Release of metallic debris is mainly in the form of micro- and nano-particles, ions of different valences, and oxides composed of Co and Cr. Though these substances alter human biology, their direct effects of these substances on specific tissue types remain poorly understood. This may partially be the consequence of the multivariate research methodologies employed, leading to inconsistent reports. This review proposes the importance of developing new and more appropriate in-vitro methodologies to study the cellular responses and toxicity mediated by joint replacement wear debris in-vivo. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Results of endoprosthetic hip joint replacement with the aluminum ceramic-metal composite prosthesis "Lindenhof".

    Science.gov (United States)

    Stock, D; Diezemann, E D; Gottstein, J

    1980-01-01

    The first clinical results of the Lindenhof ceramic-metal composite prosthesis implanted in our hospital in Freiburg are presented. We observed that same favorable early results as the conventional prostheses in a correct position. The implants are incorporated into the bone within 8-12 weeks. The radiographic films show the adaptation of the supporting bone around the ceramic socket. We explain the failures due to our initial lack of technical experience and/or anatomical deformation of the pelvic bone. complications caused by the post-operative treatment during the 12 weeks following surgery did not occur. The combination of a cemented metal femoral component with a ceramic head seems to be a reasonable compromise to use the favorable physical and biochemical properties of the bioceramic material as long as there is no satisfactory solution for a stable cementless fixation of the femoral stem in to the bone. The advantages of the Lindenhof prosthesis predominate the disadvantages: expensive instruments and a post-operative treatment of several months.

  5. Hip Replacement

    Science.gov (United States)

    Hip replacement is surgery for people with severe hip damage. The most common cause of damage is osteoarthritis. Osteoarthritis ... pain medicines, and exercise haven't helped, hip replacement surgery might be an option for you. During ...

  6. Equilibrium resurfacing of Venus: Results from new Monte Carlo modeling and implications for Venus surface histories

    Science.gov (United States)

    Bjonnes, E. E.; Hansen, V. L.; James, B.; Swenson, J. B.

    2012-02-01

    Venus' impact crater population imposes two observational constraints that must be met by possible model surface histories: (1) near random spatial distribution of ˜975 craters, and (2) few obviously modified impact craters. Catastrophic resurfacing obviously meets these constraints, but equilibrium resurfacing histories require a balance between crater distribution and modification to be viable. Equilibrium resurfacing scenarios with small incremental resurfacing areas meet constraint 1 but not 2, whereas those with large incremental resurfacing areas meet constraint 2 but not 1. Results of Monte Carlo modeling of equilibrium resurfacing ( Strom et al., 1994) is widely cited as support for catastrophic resurfacing hypotheses and as evidence against hypotheses of equilibrium resurfacing. However, the Monte Carlo models did not consider intermediate-size incremental resurfacing areas, nor did they consider histories in which the era of impact crater formation outlasts an era of equilibrium resurfacing. We construct three suites of Monte Carlo experiments that examine incremental resurfacing areas not previously considered (5%, 1%, 0.7%, and 0.1%), and that vary the duration of resurfacing relative to impact crater formation time (1:1 [suite A], 5:6 [suite B], and 2:3 [suite C]). We test the model results against the two impact crater constraints. Several experiments met both constraints. The shorter the time period of equilibrium resurfacing, or the longer the time of crater formation following the cessation of equilibrium resurfacing, the larger the possible areas of incremental resurfacing that satisfy both constraints. Equilibrium resurfacing is statistically viable for suite A at 0.1%, suite B at 0.1%, and suite C for 1%, 0.7%, and 0.1% areas of incremental resurfacing.

  7. Increased metal allergy in patients with failed metal-on-metal hip arthroplasty and peri-implant T-lymphocytic inflammation.

    Science.gov (United States)

    Thomas, P; Braathen, L R; Dörig, M; Auböck, J; Nestle, F; Werfel, T; Willert, H G

    2009-08-01

    In 16 patients with revised metal-on-metal arthroplasty and peri-implant lymphocytic inflammation, we verified the role of metal hypersensitivity by patch testing (PT) and lymphocyte transformation test (LTT). In the 16 patients with lymphocyte dominated periprosthetic inflammation, allergy history was obtained by a questionnaire, specific serum IgE to aeroallergens was measured to assess atopy, PT to standard and metal series was performed and metal sensitivity was further assessed by LTT using blood mononuclear cells. Revision surgery was performed because of pain (8/16), osteolysis (4/16), dislocation (3/16) and loosening of the stem (1/16). Histological examination showed perivascular infiltrates of T lymphocytes, high endothelial venules, fibrin exudation and accumulation of macrophages with drop-like inclusions. Five patients had a history of cutaneous metal allergy and atopy was found in 25% of the patients. In 13/16 patients (81%), systemic metal sensitivity was found based on PT and/or LTT. Patch test reactions were seen in 11/16 patients (69%; partly multiple reactions/patient): 7/16 to Cobalt (Co), 7/16 to Chromium (Cr), 4/16 to Nickel (Ni), and one each to Molybdenum (Mo) and Manganese (Mn). Ten of 16 patients (62%) showed enhanced LTT reactivity to metals: 7/16 to Ni, 7/16 to Co, 5/16 to Cr, 5/16 to Mo and 4/16 to Mn. The lymphocyte dominated peri-implant inflammation may well reflect an allergic hyper-reactivity in these patients, given the high rate of concomitantly found metal allergy. Despite the overall incidence of metal implant allergy being low, allergic reactions should be included as differential diagnosis in failed metal-on-metal arthroplasty.

  8. Antibiotic-laden Arthroplasty with a Novel Design of Cement Mould and Metallic Endoskeleton for Treatment of Hip Infection, an Inexpensive Alternative: A Preliminary Report of Two Cases

    Directory of Open Access Journals (Sweden)

    William CCH

    2017-07-01

    Full Text Available Infection of the hip after implant fixation is an uncommon yet devastating complication that results in poor long-term outcome. The gold standard treatment for chronic infection after hip arthroplasty is a two-stage protocol: eradication of infection, follow by re-implantation arthroplasty. The use of interim antibiotic-laden cement spacer has become a popular procedure to maintain hip joint function and provide antibiotic elution simultaneously before re-implantation. However, antibiotic cement spacer is mechanically weak and breaks if overloaded. Therefore, we designed a cement mould with metallic endoskeleton with the aim of creating a stronger, inexpensive, antibiotic-impregnated spacer resembling a unipolar arthroplasty. We report two cases of severe hip joint infection after implant fixation (bipolar hemiarthroplasty, screw fixation neck of femur. Both patients had undergone first stage surgery of debridement and articulating antibiotic cement insertion using our design. Although the second stage surgery was planned for these patients, both patients delayed the operation in view of good functional status after a year walking with the antibiotic cement spacer. These cases showed that the mechanical property of the new antibiotic cement spacer was promising but further mechanical studies upon this new endoskeleton design are required.

  9. Antibiotic-laden Arthroplasty with a Novel Design of Cement Mould and Metallic Endoskeleton for Treatment of Hip Infection, an Inexpensive Alternative: A Preliminary Report of Two Cases.

    Science.gov (United States)

    William, Cch; Simmrat, S; Suhaeb, A M

    2017-07-01

    Infection of the hip after implant fixation is an uncommon yet devastating complication that results in poor long-term outcome. The gold standard treatment for chronic infection after hip arthroplasty is a two-stage protocol: eradication of infection, follow by re-implantation arthroplasty. The use of interim antibiotic-laden cement spacer has become a popular procedure to maintain hip joint function and provide antibiotic elution simultaneously before re-implantation. However, antibiotic cement spacer is mechanically weak and breaks if overloaded. Therefore, we designed a cement mould with metallic endoskeleton with the aim of creating a stronger, inexpensive, antibiotic-impregnated spacer resembling a unipolar arthroplasty. We report two cases of severe hip joint infection after implant fixation (bipolar hemiarthroplasty, screw fixation neck of femur). Both patients had undergone first stage surgery of debridement and articulating antibiotic cement insertion using our design. Although the second stage surgery was planned for these patients, both patients delayed the operation in view of good functional status after a year walking with the antibiotic cement spacer. These cases showed that the mechanical property of the new antibiotic cement spacer was promising but further mechanical studies upon this new endoskeleton design are required.

  10. MR imaging with metal artifact-reducing sequences and gadolinium contrast agent in a case-control study of periprosthetic abnormalities in patients with metal-on-metal hip prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Gunilla M.; Mueller, Markus F.; Ekberg, Olle [Lund University, Skaane University Hospital, Department of Radiology, Malmoe (Sweden); Maansson, Sven [Lund University, Skaane University Hospital, Department of Medical Radiation Physics, Malmoe (Sweden); Schewelov, Thord von [Lund University, Skaane University Hospital, Department of Orthopedic Surgery, Malmoe (Sweden); Nittka, Mathias [Siemens AG, Healthcare Sector, Erlangen (Germany); Lundin, Bjoern [Lund University, Skaane University Hospital, Department of Radiology, Lund (Sweden)

    2014-08-15

    To apply and compare magnetic resonance imaging (MRI) metal artifact reducing sequences (MARS) including subtraction imaging after contrast application in patients with metal-on-metal (MoM) hip prostheses, investigate the prevalence and characteristics of periprosthetic abnormalities, as well as their relation with pain and risk factors. Fifty-two MoM prostheses (35 cases with pain and or risk factors, and 17 controls) in 47 patients were examined in a 1.5-T MR scanner using MARS: turbo spin echo (TSE) with high readout bandwidth with and without view angle tilting (VAT), TSE with VAT and slice encoding for metal artifact correction (SEMAC), short tau inversion recovery (STIR) with matched RF pulses, and post-contrast imaging. The relations of MRI findings to pain and risk factors were analyzed and in five revised hips findings from operation, histology, and MRI were compared. TSE VAT detected the highest number of osteolyses. Soft tissue mass, effusion, and capsular thickening were common, whereas osteolysis in acetabulum and femur were less frequent. Contrast enhancement occurred in bone, synovia, joint capsule, and the periphery of soft tissue mass. There was no significant relation between MRI findings and pain or risk factors. MARS and gadolinium subtraction imaging are useful for evaluation of complications to MoM prosthesis. TSE VAT had the highest sensitivity for osteolysis. Contrast enhancement might indicate activation of aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL). Pain, small head, or steep prosthesis inclination angle are not useful predictors of periprosthetic abnormalities, and wide indications for MR follow-up are warranted. (orig.)

  11. Total hip prosthesis CT with single-energy projection-based metallic artifact reduction: impact on the visualization of specific periprosthetic soft tissue structures

    Energy Technology Data Exchange (ETDEWEB)

    Gondim Teixeira, Pedro Augusto [CHU-Nancy, Service D' Imagerie Guilloz, Nancy (France); UMR, S 947, Universite de Lorraine, IADI, Nancy (France); Meyer, Jean-Baptiste; Raymond, Ariane; Blum, Alain [CHU-Nancy, Service D' Imagerie Guilloz, Nancy (France); Baumann, Cedric [CHU-Nancy, Service d' Epidemiologie et Evaluation Cliniques, Nancy (France); Sirveaux, Francois [Service de Chirurgie Traumatologique et Orthopedique, Nancy (France); Coudane, Henry [CHU-Nancy, Service de Chirurgie Traumatologique et Arthroscopique de l' Appareil Locomoteur (ATOL), Nancy (France)

    2014-09-15

    To compare the image quality of CT with iterative reconstruction alone and in association with projection-based single-energy metal artifact reduction (SEMAR) for the visualization of specific periarticular soft tissue structures in patients with hip prostheses. CT studies from 48 consecutive patients with a hip prosthesis (24 unilateral and 24 bilateral) were retrospectively reconstructed using two different methods: iterative reconstruction (IR) alone and IR associated with SEMAR. The influence of metallic artifacts on the identification of various periarticular structures was evaluated subjectively by two readers. The image quality was compared in patients with unilateral and bilateral prostheses. Visualization of periprosthetic soft tissue was significantly improved by the SEMAR algorithm (p < 0.0001). When SEMAR was associated with IR, the gluteus minimus and medius tendons, obturator internus muscle, prostate/uterus and bladder could be seen with medium or high confidence. There were no significant differences in image quality between patients with unilateral or bilateral prosthesis when SEMAR was used (p > 0.2). This algorithm increased the detection of periarticular masses by 30 %. SEMAR significantly improves the image quality of periarticular soft-tissue structures in patients with hip prostheses. (orig.)

  12. Benefits of Hot Isostatic Pressure/Powdered Metal (HIP/PM) and Additive Manufacturing (AM) To Fabricate Advanced Energy System Components

    Energy Technology Data Exchange (ETDEWEB)

    Horton, Nancy [Energy Industries of Ohio, Cleveland, OH (United States); Sheppard, Roy [Energy Industries of Ohio, Cleveland, OH (United States)

    2016-12-31

    Advanced Energy systems require large, complex components produced from materials capable of withstanding severe operating environments (high temperature, pressure, corrosivity). Such parts can be difficult to source, as conventional material processing technologies must be tailored to ensure a safe and cost effective approach to large-scale manufacture of quality structural advanced alloy components that meet the performance specifications of AE systems. (HIP/PM) has shown advantages over other manufacturing methods when working with these materials. For example, using HIP’ing in lieu of casting means significant savings in raw material costs, which for expensive, high-nickel alloys can be considerable for large-scale production. Use of HIP/PM also eliminates the difficulties resulting from reactivity of these materials in the molten state and facilitates manufacture of the large size requirements of the AE industry, producing a part that is defect and porosity free, thus further reducing or eliminating time and expense of post processing machining and weld repair. New advances in Additive Manufacturing (AM) techniques make it possible to further expand the benefits of HIP/PM in producing AE system components to create an even more robust manufacturing approach. Traditional techniques of welding and forming sheet metal to produce the HIP canisters can be time consuming and costly, with limitations on the complexity of part which can be achieved. A key benefit of AM is the freedom of design that it offers, so use of AM could overcome such challenges, ultimately enabling redesign of complete energy systems. A critical step toward this goal is material characterization of the required advanced alloys, for use in AM. Using Haynes 282, a high nickel alloy of interest to the Fossil Energy community, particularly for Advanced-UltraSuperCritical (AUSC) operating environments, as well as the crosscutting interests of the aerospace, defense and medical markets, this

  13. Maximizing benefits and minimizing risk with CO2 laser resurfacing.

    Science.gov (United States)

    Fitzpatrick, Richard E

    2002-01-01

    Laser resurfacing using the high-energy, pulsed and scanned CO2 laser produces the most dramatic improvement in severe photo-induced facial rhytides and deeply atrophic scars. More recently, the use of short- and long-pulsed erbium lasers in conjunction with CO2 laser resurfacing has been shown to speed healing by removing the upper layer of thermally induced necrotic tissue. The Er:YAG lasers are more superficial ablative tools that inflict less residual thermal damage on the tissue, thus allowing healing to occur without the requisite internal clearance of excessive debris. With continued research and advances in laser surgery, cutaneous resurfacing will be further enhanced with improved outcomes and lessened morbidity.

  14. Hip Fracture

    Science.gov (United States)

    ... hip fractures in people of all ages. In older adults, a hip fracture is most often a result of a fall from a standing height. In people with very weak bones, a hip fracture can occur simply by standing on the leg and twisting. Risk factors The rate of hip fractures increases substantially with ...

  15. High Early Major Complication Rate After Revision for Mechanically Assisted Crevice Corrosion in Metal-on-Polyethylene Total Hip Arthroplasty.

    Science.gov (United States)

    McGrory, Brian J; Jorgensen, Anna H

    2017-12-01

    Failed total hip arthroplasty caused by mechanically assisted crevice corrosion (MACC) has serious consequences such as adverse local tissue reaction. Revision is currently indicated for significant hip pain, stiffness, and dysfunction; hip instability; progressive bone loss; and soft tissue destruction. Outcomes of this revision surgery are not yet completely understood. We examined the surgical outcomes at a minimum of 6 months (average, 25; range, 7-68 months) in a cohort of 27 consecutive patients who underwent revision total hip arthroplasty for MACC associated with a single implant vendor and taper type. Major orthopedic complications occurred in 7 of 27 patients (25.9%), each after the original revision surgery. Five additional major complications occurred in subsequent surgeries. Postoperative hip dislocation occurred in 6 of 27 (22.2%), deep infection occurred in 3 of 27 (11.1%), and aseptic acetabular loosening, seroma requiring irrigation and debridement, pulmonary embolism, periprosthetic fracture, and reintubation each occurred in 1 of 27 (3.7%). Harris hip scores improved significantly with surgery (P = .0002), but overall, scores were lower for those who had major complications (70.9 vs 89.2), and only 20 of 27 patients (74.1%) had good or excellent outcomes. Symptomatic MACC is a potentially devastating diagnosis, because of decreased soft tissue and bone viability associated with adverse local tissue reaction. This leads to a high early major complication rate. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Risk of revision following total hip arthroplasty: metal-on-conventional polyethylene compared with metal-on-highly cross-linked polyethylene bearing surfaces: international results from six registries.

    Science.gov (United States)

    Paxton, Elizabeth; Cafri, Guy; Havelin, Leif; Stea, Susanna; Pallisó, Francesc; Graves, Stephen; Hoeffel, Daniel; Sedrakyan, Art

    2014-12-17

    The results of randomized controlled trials and systematic reviews have suggested reduced radiographic wear in highly cross-linked polyethylene compared with conventional polyethylene in primary total hip arthroplasty. However, longer-term clinical results have not been thoroughly examined, to our knowledge. The purpose of this study was to compare the risk of revision for metal-on-conventional and metal-on-highly cross-linked total hip arthroplasty bearing surfaces with use of a distributed data network of six national and regional registries (Kaiser Permanente, HealthEast, the Emilia-Romagna region in Italy, the Catalan region in Spain, Norway, and Australia). Inclusion criteria were osteoarthritis as the primary diagnosis, cementless implant fixation, and a patient age of forty-five to sixty-four years. These criteria resulted in a sample of 16,571 primary total hip arthroplasties. Multivariate meta-analysis was performed with use of linear mixed models, with survival probability as the unit of analysis. The results of a fixed-effects model suggested that there was insufficient evidence of a difference in risk of revision between bearing surfaces (hazard ratio, 1.20 [95% confidence interval, 0.80 to 1.79]; p = 0.384). Highly cross-linked polyethylene does not appear to have a reduced risk of revision in this subgroup of total hip arthroplasty patients. Arthroplasties involving highly cross-linked polyethylene do not appear to have an increased risk of revision in this subgroup of total hip arthroplasty patients. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  17. Metal-metal-hofteproteser

    DEFF Research Database (Denmark)

    Ulrich, Michael; Overgaard, Søren; Penny, Jeannette

    2014-01-01

    In Denmark 4,456 metal-on-metal (MoM) hip prostheses have been implanted. Evidence demonstrates that some patients develope adverse biological reactions causing failures of MoM hip arthroplasty. Some reactions might be systemic. Failure rates are associated with the type and the design of the Mo......M hip implant. A Danish surveillance programme has been initiated addressing these problems....

  18. Metal-metal-hofteproteser

    DEFF Research Database (Denmark)

    Ulrich, Michael; Overgaard, Søren; Penny, Jeannette

    2014-01-01

    In Denmark 4,456 metal-on-metal (MoM) hip prostheses have been implanted. Evidence demonstrates that some patients develope adverse biological reactions causing failures of MoM hip arthroplasty. Some reactions might be systemic. Failure rates are associated with the type and the design of the Mo...

  19. Hip pain

    Science.gov (United States)

    ... from a chair, walking, climbing stairs, and driving Hamstring strain Iliotibial band syndrome Hip flexor strain Hip ... and cool down afterward. Stretch your quadriceps and hamstrings. Avoid running straight down hills. Walk down instead. ...

  20. Hip joint replacement

    Science.gov (United States)

    Hip arthroplasty; Total hip replacement; Hip hemiarthroplasty; Arthritis - hip replacement; Osteoarthritis - hip replacement ... your activities. Most of the time, hip joint replacement is done in people age 60 and older. ...

  1. Resurfacing hemiarthroplasty compared to stemmed hemiarthroplasty for glenohumeral osteoarthritis

    DEFF Research Database (Denmark)

    Rasmussen, Jeppe V; Olsen, Bo S; Sorensen, Anne Kathrine

    2015-01-01

    PURPOSE: The aim of this study was to conduct a randomised, clinical trial comparing stemmed hemiarthroplasty and resurfacing hemiarthroplasty in the treatment of glenohumeral osteoarthritis. METHODS: A total of 40 shoulders (35 patients) were randomised to stemmed hemiarthroplasty or resurfacing...... hemiarthroplasty and evaluated three and 12 months postoperatively using the Constant-Murley score (CMS) and Western Ontario Osteoarthritis of the Shoulder (WOOS) index. RESULTS: There were no statistically significant differences in age, gender or pre-operative scores except for WOOS at baseline. Two patients...... to be inferior to those of stemmed hemiarthroplasty. It is unclear whether this reflects a real difference in effect or baseline differences due to the limited number of randomised patients. We suggest there is a need for a larger, more definitive trial....

  2. Native Patella Retention Versus Resurfacing in a Cohort of Staged Bilateral Total Knee Patients

    Directory of Open Access Journals (Sweden)

    Justin M Head

    2017-10-01

    Full Text Available Background: Patellar resurfacing in total knee arthroplasty remains a point of controversy within the literature and the generally followed paradigm varies among regions. Methods: In effort to elucidate a difference following the change from universal patellar resurfacing to universal non-resurfacing, 32 patients with bilateral TKA that included one resurfaced and one native patella were retrospectively reviewed at average follow up 21.4 months from the most recent surgery. Results: No difference was observed in patient satisfaction, KOOS-ADL score, and VAS scores. No complications or secondary patellar resurfacing occurred. Conclusions: Therefore, patients perceive no difference between knees with native patella retention or a resurfaced patella in regards to pain and function.

  3. Thermal injuries as a result of CO2 laser resurfacing.

    Science.gov (United States)

    Grossman, A R; Majidian, A M; Grossman, P H

    1998-09-01

    CO2 laser resurfacing of the face for fine wrinkles has gained great popularity over a short period of time. The use of the CO2 laser has proven to be effective in reducing or eliminating fine wrinkles. This tool in the surgeon's armamentarium has been added to those of dermabrasion and chemical peel. The theoretical advantage of the use of the CO2 laser for resurfacing has been better accuracy and reportedly more control of the depth of penetration. The use of the CO2 laser has been welcomed by many cosmetic surgeons. Until now, there have been few reported cases of complications with the use of the CO2 laser. To many, this would sound too good to be true; unfortunately, that is the case. The CO2 laser is a high-energy machine that can indeed cause thermal injury. This thermal injury can result in deep burns to the skin and hypertrophic scarring. We feel this is more common than is currently being reported, and we share our experience as a burn and wound care referral service. During an 18-month period, 20 consecutive patients were referred to our practice who had received injuries from the CO2 laser resurfacing laser. We present here in this review a summary of those injuries. The CO2 resurfacing laser is a very effective tool for the treatment of fine wrinkles, but it is not without the potential for serious complications. We urge caution with the use of the laser and prompt recognition and treatment of thermal injury to the skin.

  4. Pseudotumour formation and subsequent resolution in metal-on-metal total hip arthroplasty following revision: Instructional review and an illustrative case report with revision using a dual mobility design.

    Science.gov (United States)

    Sassoon, A A; Barrack, R L

    2016-06-01

    The use of large-diameter metal-on-metal (MoM) components in total hip arthroplasty (THA) is associated with an increased risk of early failure due to adverse local tissue reaction to metal debris (ARMD) in response to the release of metal ions from the bearing couple and/or head-neck taper corrosion. The aim of this paper was to present a review of the incidence and natural history of ARMD and the forms of treatment, with a focus on the need for and extent of resection or debulking of the pseudotumour. An illustrative case report is presented of a patient with an intra-pelvic pseudotumour associated with a large diameter MoM THA, which was treated successfully with revision of the bearing surface to a dual mobility couple and retention of the well-fixed acetabular and femoral components. The pseudotumour was left in situ Resolution of the intra-pelvic mass and normalisation of metal ion levels was observed seven months post-operatively. Cite this article: Bone Joint J 2016;98-B:736-40. ©2016 The British Editorial Society of Bone & Joint Surgery.

  5. The Content of the 14 Metals in Cancellous and Cortical Bone of the Hip Joint Affected by Osteoarthritis

    Science.gov (United States)

    Zioła-Frankowska, Anetta; Kubaszewski, Łukasz; Dąbrowski, Mikołaj; Kowalski, Artur; Rogala, Piotr; Strzyżewski, Wojciech; Łabędź, Wojciech; Kanicky, Viktor

    2015-01-01

    The aim of the study was to determine the content of particular elements Ca, Mg, P, Na, K, Zn, Cu, Fe, Mo, Cr, Ni, Ba, Sr, and Pb in the proximal femur bone tissue (cancellous and cortical bone) of 96 patients undergoing total hip replacement for osteoarthritis using ICP-AES and FAAS analytical techniques. The interdependencies among these elements and their correlations depended on factors including age, gender, place of residence, tobacco consumption, alcohol consumption, exposure to environmental pollution, physical activity, and type of degenerative change which were examined by statistical and chemometric methods. The factors that exerted the greatest influence on the elements in the femoral head and neck were tobacco smoking (higher Cr and Ni content in smokers), alcohol consumption (higher concentrations of Ni, Cu in people who consume alcohol), and gender (higher Cu, Zn, and Ni concentrations in men). The factors influencing Pb accumulation in bone tissue were tobacco, alcohol, gender, and age. In primary and secondary osteoarthritis of the hip, the content and interactions of elements are different (mainly those of Fe and Pb). There were no significant differences in the concentrations of elements in the femoral head and neck that could be attributed to residence or physical activity. PMID:26357659

  6. The Effect of Prior Hip Arthroscopy on Patient-Reported Outcomes After Total Hip Arthroplasty: An Institutional Registry-Based, Matched Cohort Study.

    Science.gov (United States)

    Konopka, Joseph F; Buly, Robert L; Kelly, Bryan T; Su, Edwin P; McLawhorn, Alexander S

    2018-02-02

    A significant number of patients who undergo hip arthroscopy will subsequently undergo total hip arthroplasty (THA) or hip resurfacing arthroplasty (HRA), although limited evidence exists regarding effects of prior hip arthroscopy on the outcomes of these procedures. Of 5091 patients who underwent hip arthroscopy, we identified 69 patients who underwent subsequent THA (46) or HRA (23). Patients were matched to patients with no history of hip arthroscopy. Preoperative and 2-year postoperative Hip disability and Osteoarthritis Outcome Score, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Short Form-12, Lower Extremity Activity Scale score, and satisfaction surveys were compared. Patients who underwent THA with history of arthroscopy had lower postoperative Hip disability and Osteoarthritis Outcome Score Pain (82 ± 16 vs 93 ± 9, P = .003), Stiffness (85 ± 16 vs 93 ± 15, P = .01), Sports and Recreation (71 ± 22 vs 88 ± 18, P = .003), Quality-of-Life (65 ± 22 vs 86 ± 11, P Hip arthroscopy before hip arthroplasty is associated with slightly lower results in several patient-reported outcomes. These results are relevant when assessing patients for hip arthroscopy and when counseling prospective arthroplasty patients with history of arthroscopy. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. The Infection Rate of Metal-on-Metal Total Hip Replacement Is Higher When Compared to Other Bearing Surfaces as Documented by the Australian Orthopaedic Association National Joint Replacement Registry.

    Science.gov (United States)

    Huang, Phil; Lyons, Matt; O'Sullivan, Michael

    2018-02-01

    Despite the well-documented decline in the use of metal-on-metal (MoM) implants over the last decade, there are still controversies regarding whether all MoM implants are created equally. Complications such as elevated serum metal ion levels, aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL) and pseudotumours have all been well documented, but recent studies suggest increased risk of infection with MoM bearing surfaces. Most of these studies however have small patient numbers. The purpose of this study was to examine the cumulative incidence of revision for infection of MoM bearing surfaces in primary hip arthroplasty at a national and single-surgeon level. Data was collected from the Australian Orthopaedic Association National Joint Replacement Registry, which contains over 98% of all arthroplasties performed in Australia since 2001. The cumulative incidence of revision for infection was extracted at a national level and single-surgeon level. Two hundred seventy-six thousand eight hundred seventy-eight subjects were documented in the Australian registry. The 10-year cumulative percent revision for infection of MoM bearing surfaces in primary total hip replacement (THR) was 2.5% at a national level, compared to 0.8% for other bearing surfaces. The senior author contributed 1755 subjects with 7-year follow-up and a cumulative percent revision for infection of MoM bearing surfaces in primary THR of 36.9%, compared to 2.0% for other bearing surfaces. The cumulative percent of revision of MoM bearing surfaces is higher compared to other bearing surfaces; this is especially pronounced in cumulative percent of revision for infection. There was a higher cumulative percent of revision for infection in MoM bearings surfaces (in particular, large-head MoM) compared to other bearing surfaces at both the national and individual-surgeon level.

  8. Aesthetic skin resurfacing with the high-energy ultrapulsed CO2 laser.

    Science.gov (United States)

    Weinstein, C; Roberts, T L

    1997-04-01

    CO2 laser resurfacing, using the new generation high-energy output pulsed lasers, provides a highly accurate method of resurfacing and rejuvenating facial skin. Its applications are widespread and well accepted by the general population (Color Figs. 3 to 8). Complications may occur, which may be minimized through adequate laser training and appreciation of the mechanisms of skin healing.

  9. Total hip arthroplasty revision by dual-mobility acetabular cup cemented in a metal reinforcement: A 62 case series at a minimum 5 years' follow-up.

    Science.gov (United States)

    Lebeau, N; Bayle, M; Belhaouane, R; Chelli, M; Havet, E; Brunschweiler, B; Mertl, P

    2017-09-01

    Total hip arthroplasty (THA) requires bone reconstruction in case of severe acetabular injury, with risk of dislocation, especially postoperatively. Dual-mobility cups have proved effective in preventing dislocation in THA revision for instability, but their behavior when cemented in a metal reinforcement has been little studied. The present study assessed results for a dual-mobility cup cemented in a metal reinforcement, in terms of aseptic loosening and postoperative instability. A single-center continuous series of 62 patients receiving such an assembly in THA revision was assessed retrospectively at a minimum 5 years' follow-up. Failure due to aseptic loosening or instability and implant survival at last follow-up were analyzed. Radiological and clinical analysis was performed at a mean 77 months' follow-up. Mean Merle-d'Aubigné-Postel score was 14, Harris score 73 and Oxford-12 score 23.9 at last follow-up. Complications comprised 5 cases of loosening and 2 of dislocation. Loosening risk was significantly greater in case ofrevision with severe bone loss. IV, retrospective study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  10. The effect of metal artefact reduction on CT-based attenuation correction for PET imaging in the vicinity of metallic hip implants : a phantom study

    NARCIS (Netherlands)

    Harnish, Roy; Prevrhal, Sven; Alavi, Abass; Zaidi, Habib; Lang, Thomas F.

    To determine if metal artefact reduction (MAR) combined with a priori knowledge of prosthesis material composition can be applied to obtain CT-based attenuation maps with sufficient accuracy for quantitative assessment of F-18-fluorodeoxyglucose uptake in lesions near metallic prostheses. A custom

  11. Resurfacing asteroids from YORP spin-up and failure

    Science.gov (United States)

    Graves, Kevin J.; Minton, David A.; Hirabayashi, Masatoshi; DeMeo, Francesca E.; Carry, Benoit

    2018-04-01

    The spectral properties of S and Q-type asteroids can change over time due to interaction with the solar wind and micrometeorite impacts in a process known as 'space weathering.' Space weathering raises the spectral slope and decreases the 1 μm absorption band depth in the spectra of S and Q-type asteroids. Over time, Q-type asteroids, which have very similar spectra to ordinary chondrite meteorites, will change into S-type asteroids. Because there are a significant number of Q-type asteroids, there must be some process which is resurfacing S-type asteroids into Q-types. In this study, we use asteroid data from the Sloan Digital Sky Survey to show a trend between the slope through the g‧, r‧, and i‧ filters, called the gri-slope, and size that holds for all populations of S and Q-type asteroids in the inner solar system, regardless of orbit. We model the evolution of a suite of asteroids in a Monte Carlo YORP rotational evolution and space weathering model. We show that spin-up and failure from YORP is one of the key resurfacing mechanisms that creates the observed weathering trends with size. By varying the non-dimensional YORP coefficient and running time of the present model over the range 475-1425 Myr, we find a range of values for the space weathering timescale, τSW ≈ 19-80 Myr at 2.2 AU. We also estimate the time to weather a newly resurfaced Q-type asteroid into an S-complex asteroid at 1 AU, τQ → S(1AU) ≈ 2-7 Myr.

  12. Multi-phase volcanic resurfacing at Loki Patera on Io.

    Science.gov (United States)

    de Kleer, K; Skrutskie, M; Leisenring, J; Davies, A G; Conrad, A; de Pater, I; Resnick, A; Bailey, V; Defrère, D; Hinz, P; Skemer, A; Spalding, E; Vaz, A; Veillet, C; Woodward, C E

    2017-05-10

    The Jovian moon Io hosts the most powerful persistently active volcano in the Solar System, Loki Patera. The interior of this volcanic, caldera-like feature is composed of a warm, dark floor covering 21,500 square kilometres surrounding a much cooler central 'island'. The temperature gradient seen across areas of the patera indicates a systematic resurfacing process, which has been seen to occur typically every one to three years since the 1980s. Analysis of past data has indicated that the resurfacing progressed around the patera in an anti-clockwise direction at a rate of one to two kilometres per day, and that it is caused either by episodic eruptions that emplace voluminous lava flows or by a cyclically overturning lava lake contained within the patera. However, spacecraft and telescope observations have been unable to map the emission from the entire patera floor at sufficient spatial resolution to establish the physical processes at play. Here we report temperature and lava cooling age maps of the entire patera floor at a spatial sampling of about two kilometres, derived from ground-based interferometric imaging of thermal emission from Loki Patera obtained on 8 March 2015 ut as the limb of Europa occulted Io. Our results indicate that Loki Patera is resurfaced by a multi-phase process in which two waves propagate and converge around the central island. The different velocities and start times of the waves indicate a non-uniformity in the lava gas content and/or crust bulk density across the patera.

  13. Recontouring, resurfacing, and scar revision in skin cancer reconstruction.

    Science.gov (United States)

    Brenner, Michael J; Perro, Christopher A

    2009-08-01

    Residual disfigurement is a common problem for patients who have undergone skin cancer reconstruction. Restoring form and function in these patients is an artistic and technical endeavor. The efficacy of surgical scar revision, dermabrasion, chemical peels, and laser resurfacing is predicated upon the skin's innate ability to regenerate over time in response to mechanical, chemical, and thermal or ablative stresses. The patient and surgeon should be accepting of a process that is often gradual and may proceed in stages. Achieving proficiency with the secondary procedures for improving scars and local flaps may allow the motivated surgeon to mold an initially passable surgical result into an excellent one.

  14. Comparison of the risk of revision in cementless total hip arthroplasty with ceramic-on-ceramic and metal-on-polyethylene bearings

    Science.gov (United States)

    Varnum, Claus; Pedersen, Alma B; Kjærsgaard-Andersen, Per; Overgaard, Søren

    2015-01-01

    Background and purpose Ceramic-on-ceramic (CoC) bearings were introduced in total hip arthroplasty (THA) to reduce problems related to polyethylene wear. We compared the 9-year revision risk for cementless CoC THA and for cementless metal-on-polyethylene (MoP) THA. Patients and methods In this prospective, population-based study from the Danish Hip Arthroplasty Registry, we identified all the primary cementless THAs that had been performed from 2002 through 2009 (n = 25,656). Of these, 1,773 THAs with CoC bearings and 9,323 THAs with MoP bearings were included in the study. To estimate the relative risk (RR) of revision, we used regression with the pseudo-value approach and treated death as a competing risk. Results 444 revisions were identified: 4.0% for CoC THA (71 of 1,773) and 4.0% for MoP THA (373 of 9,323). No statistically significant difference in the risk of revision for any reason was found for CoC and MoP bearings after 9 years of follow-up (adjusted RR = 1.3, 95% CI: 0.72–2.4). Revision rates due to component failure were 0.5% (n = 8) for CoC bearings and 0.1% (n = 6) for MoP bearings (p revision due to ceramic fracture. Interpretation When compared to the “standard” MoP bearings, CoC THA had a 33% higher (though not statistically significantly higher) risk of revision for any reason at 9 years. PMID:25637339

  15. Hip Pain

    Science.gov (United States)

    ... diagnosis and decision making. In: DeLee & Drez's Orthopaedic Sports Medicine: Principles and Practice. 4th ed. Philadelphia, Pa.: ... http://www.mayoclinic.org/symptoms/hip-pain/basics/definition/SYM-20050684 . Mayo Clinic Footer Legal Conditions and ...

  16. Rose Hip

    Science.gov (United States)

    ... shows that taking rose hip powder mixed with apple juice does not affect weight or blood sugar ... Rose, Phool Gulab, Pink Rose, Poire d'oiseaux, Rosa alba, Rosa canina, Rosa centifolia, Rosa damascena, Rosa ...

  17. Hip ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Martinoli, Carlo, E-mail: carlo.martinoli@libero.it [Radiologia, DISC, Università di Genova, Largo Rosanna Benzi 8, I-16132 Genoa (Italy); Garello, Isabella; Marchetti, Alessandra; Palmieri, Federigo; Altafini, Luisa [Radiologia, DISC, Università di Genova, Largo Rosanna Benzi 8, I-16132 Genoa (Italy); Valle, Maura [Radiologia, Gaslini Children Hospital, Genova (Italy); Tagliafico, Alberto [Radiologia, National Institute for Cancer Research, Genoa (Italy)

    2012-12-15

    In newborns, US has an established role in the detection and management of developmental dysplasia of the hip. Later in childhood, when the limping child is a major diagnostic dilemma, US is extremely helpful in the identification of the varied disease processes underlying this condition, as transient synovitis, septic arthritis, Perthes disease and slipped femoral capital epiphysis. In adolescent practicing sporting activities, US is an excellent means to identify apophyseal injures about the pelvic ring, especially when avulsions are undisplaced and difficult-to-see radiographically. Later on, in the adulthood, US is an effective modality to diagnose tendon and muscle injuries about the hip and pelvis, identify effusion or synovitis within the hip joint or its adjacent bursae and guide the treatment of these findings. The aim of this article is to provide a comprehensive review of the most common pathologic conditions about the hip, in which the contribution of US is relevant for the diagnostic work-up.

  18. Thermal measurements of short-duration CO2 laser resurfacing

    Science.gov (United States)

    Harris, David M.; Fried, Daniel; Reinisch, Lou; Bell, Thomas; Lyver, Rex

    1997-05-01

    The thermal consequences of a 100 microsecond carbon-dioxide laser used for skin resurfacing were examined with infrared radiometry. Human skin was evaluated in a cosmetic surgery clinic and extirpated rodent skin was measured in a research laboratory. Thermal relaxation following single pulses of in vivo human and ex vivo animal skin were quantitatively similar in the 30 - 1000 msec range. The thermal emission from the area of the irradiated tissue increased monotonically with increasing incident laser fluence. Extremely high peak temperatures during the 100 microsecond pulse are attributed to plume incandescence. Ejecta thermal emission may also contribute to our measurements during the first several msecs. The data are combined into a thermal relaxation model. Given known coefficients, and adjusting tissue absorption to reflect a 50% water content, and thermal conductivity of 2.3 times that of water, the measured (both animal back and human forearm) and calculated values coincide. The high thermal conductance suggests preferential thermal conduction along the protein matrix. The clinical observation of a resurfacing procedure clearly shows thermal overlap and build-up is a result of sequential, adjacent pulses. A decrease of 4 - 6 degrees Celsius in surface temperature at the treatment site that appeared immediately post-Tx and gradually diminished over several days is possibly a sign of dermal convective and/or evaporative cooling.

  19. Isolated scaphotrapeziotrapezoid osteoarthritis treatment using resurfacing arthroplasty with scaphoid anchorage.

    Science.gov (United States)

    Humada Álvarez, G; Simón Pérez, C; García Medrano, B; Faour Martín, O; Marcos Rodríguez, J J; Vega Castrillo, A; Martín Ferrero, M A

    The aim of this study is to show the results of scaphotrapeziotrapezoid (STT) joint osteoarthritis treatment performing resurfacing arthroplasty with scaphoid anchorage. An observational, descriptive and retrospective study was performed. Ten patients with isolated STT joint osteoarthritis were studied between 2013 and 2015. The mean follow-up time was 26months. Clinical results, functional and subjective scores were reviewed. The patients were satisfied, achieving an average of 2.1 (0-3) on the VAS score and 16 (2 to 28) in the DASH questionnaire, and returning to work in the first three months post-surgery. Recovery of range of motion compared to the contralateral wrist was 96% in extension, 95% in flexion, 87% in ulnar deviation and 91% in radial deviation. The average handgrip strength of the wrist was 95% and pinch strength was 95% compared to the contralateral side. There were no intraoperative complications or alterations in postoperative carpal alignment. Resurfacing arthroplasty is proposed as a good and novel alternative in treating isolated SST joint arthritis. Achieving the correct balance between the strength and mobility of the wrist, without causing carpal destabilisation, is important to obtain satisfactory clinical and functional results. Copyright © 2017. Publicado por Elsevier España, S.L.U.

  20. Ternary complexes metal [Co(II), Ni(II), Cu(II) and Zn(II)]--ortho-iodohippurate (I-hip)--acyclovir. X-ray characterization of isostructural [(Co, Ni or Zn)(I-hip)(2)(ACV)(H(2)O)(3)] with stacking as a recognition factor.

    Science.gov (United States)

    Barceló-Oliver, M; Terrón, A; García-Raso, A; Fiol, J J; Molins, E; Miravitlles, C

    2004-11-01

    Four ternary metal--ortho-iodohippurate (I-hip)--acyclovir (ACV) complexes, [M(I-hip)(2)(ACV)(H(2)O)(3)] where M is Co(II) (1), Ni(II) (2), Cu (3) and Zn(II) have been obtained by reaction between the corresponding binary complexes M(II)(I-hip)(2)xnH(2)O and ACV. Three ternary complexes (M=Co, Ni and Zn) and the corresponding Zn(II)--ortho-iodohippurate binary derivative have been structurally characterized by X-ray diffraction: The studies show these three ternary complexes are isostructural and present, in solid state, an interesting stacking between the nucleobase and the aryl ring of the hippurate moiety, which probably promotes the formation of ternary complexes. Moreover, the two different ligands interact between them by means of ancillary hydrogen bonds with water molecules coordinated to the metal ion. It must be mentioned that these two recognition factors, hydrogen bonds plus stacking, could explain the reason for the isostructurality of these ternary derivatives with so different three metal ions, with diverses trends in coordination numbers and geometries. In solid state, there are two enantiomeric molecules that are related by an inversion center as the crystal-building unit (as a translational motif) for the ternary complexes.

  1. Release of zirconia nanoparticles at the metal stem-bone cement interface in implant loosening of total hip replacements.

    Science.gov (United States)

    Schunck, Antje; Kronz, Andreas; Fischer, Cornelius; Buchhorn, Gottfried Hans

    2016-02-01

    In a previous failure analysis performed on femoral components of cemented total hip replacements, we determined high volumes of abraded bone cement. Here, we describe the topography of the polished surface of polymethyl methacrylate (PMMA) bone cement containing zirconia radiopacifier, analyzed by scanning electron microscopy and vertical scanning interferometry. Zirconia spikes protruded about 300nm from the PMMA matrix, with pits of former crystal deposition measuring about 400nm in depth. We deduced that the characteristically mulberry-shaped agglomerates of zirconia crystals are ground and truncated into flat surfaces and finally torn out of the PMMA matrix. Additionally, evaluation of in vitro PMMA-on-PMMA articulation confirmed that crystal agglomerations of zirconia were exposed to grain pullout, fatigue, and abrasion. In great quantities, micron-sized PMMA wear and zirconia nanoparticles accumulate in the cement-bone interface and capsular tissues, thereby contributing to osteolysis. Dissemination of nanoparticles to distant lymph nodes and organs of storage has been reported. As sufficient information is lacking, foreign body reactions to accumulated nanosized zirconia in places of long-term storage should be investigated. The production of wear particles of PMMA bone cement in the interface to joint replacement devices, presents a local challenge. The presence of zirconia particles results in frustrated digestion attempts by macrophages, liberation of inflammatory mediators, and necrosis leading to aseptic inflammation and osteolyses. Attempts to minimize wear of articulating joints reduced the attention to the deterioration of cement cuffs. We therefore investigated polished surfaces of retrieved cuffs to demonstrate their morphology and to measure surface roughness. Industrially admixed agglomerates of the radiopacifier are abraded to micron and nano-meter sized particles. The dissemination of zirconia particles in the reticulo-endothelial system to

  2. A Multi-centre Study to Assess the Long-term Performance of the Pinnacle™ Cup With a Polyethylene-on-metal Bearing in Primary Total Hip Replacement

    Science.gov (United States)

    2017-06-27

    Rheumatoid Arthritis; Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis

  3. Biologic resurfacing of the patella bone versus patellectomy

    Directory of Open Access Journals (Sweden)

    Motamedi M

    1995-04-01

    Full Text Available In the past years, there was a tendency to excise the patella in pathologic conditions affecting this bone. The patella has many critical effects in the function of the knee joint. For example, after its exicision the force of quadriceps muscle decreases by forty percent (40% and the knee joint becomes prone to early osteoarthritic changes. For these reasons, in the recent years the "biologic resurfacing of patella" has been used in pathologic conditions instead of its complete removal. In this new method after resection of the diseased part of the bone, the fascia of the quadriceps muscle, with its intact base, is used to cover the resected part of the bone. In practice, after pain relief, the active motion of the joint is started. Then the limb is placed in a splint or brace and after a period of 3 weeks, passive motion is begun.

  4. Resurfacing shoulder arthroplasty for the treatment of severe rheumatoid arthritis

    DEFF Research Database (Denmark)

    Voorde, Pia C Ten; Rasmussen, Jeppe V; Olsen, Bo S

    2015-01-01

    BACKGROUND AND PURPOSE: There is no consensus on which type of shoulder prosthesis should be used in patients with rheumatoid arthritis (RA). We describe patients with RA who were treated with shoulder replacement, regarding patient-reported outcome, prosthesis survival, and causes of revision......, and we compare outcome after resurfacing hemi-arthroplasty (RHA) and stemmed hemi-arthroplasty (SHA). PATIENTS AND METHODS: We used data from the national Danish Shoulder Arthroplasty Registry and included patients with RA who underwent shoulder arthroplasty in Denmark between 2006 and 2010. Patient-reported...... outcome was obtained 1-year postoperatively using the Western Ontario Osteoarthritis of the Shoulder index (WOOS), and rates of revision were calculated by checking revisions reported until December 2011. The patient-reported outcome of RHA was compared to that of SHA using regression analysis...

  5. Hip Problems in Infants

    Science.gov (United States)

    ... A hip problem in infants is known as developmental dysplasia of the hip (DDH). It is when the ball of the ... later in life? Resources International Hip Dysplasia Institute, Developmental Dysplasia of the Hip (DDH) International Hip Dysplasia Institute, Hip-Healthy Swaddling ...

  6. Defining the Learning Curve for Hip Arthroscopy: A Threshold Analysis of the Volume-Outcomes Relationship.

    Science.gov (United States)

    Mehta, Nabil; Chamberlin, Peter; Marx, Robert G; Hidaka, Chisa; Ge, Yile; Nawabi, Danyal H; Lyman, Stephen

    2018-01-01

    Hip arthroscopy has emerged as a successful option for the treatment of femoroacetabular impingement and related hip disorders, but the procedure is technically challenging. To define the learning curve through which surgeons become proficient at hip arthroscopy. Cohort study; level of evidence, 3. The authors identified hip arthroscopy procedures performed by surgeons through a New York State database (Statewide Planning and Research Cooperative System) and followed those cases for additional hip surgery (total hip arthroplasty, hip resurfacing, or ipsilateral hip arthroscopy) within 5 years of the original procedure. Career volume for each case was calculated as the number of hip arthroscopy procedures that the surgeon had performed. Volume strata were identified via the stratum-specific likelihood ratio method. A Cox proportional hazards model was used to measure the effect of surgeon career volume on risk of additional hip surgery, adjusting for the following patient characteristics: age, sex, race/ethnicity, insurance type, and concurrent diagnosis of hip osteoarthritis. Among 8041 hip arthroscopies performed by 251 surgeons, 989 (12.3%) cases underwent additional hip surgery within 5 years. Four strata of surgeon career volume associated with distinct frequencies of reoperation were identified: cases in the lowest stratum (0-97) had the highest frequency of additional surgery (15.4%). Frequencies declined for cases in the medium (98-388), high (389-518), and highest (≥519) strata (13.8%, 10.1%, and 2.6%, respectively). There was an increased risk of subsequent surgery in each stratum when compared with the highest stratum (hazard ratio [95% CI]: low volume, 3.22 [2.29-4.54]; medium, 3.40 [2.41-4.82]; high, 2.81 [1.86-4.25]; P learning curve for hip arthroscopy was unexpectedly demanding. Cases performed by surgeons with career volumes ≥519 had significantly lower risk of subsequent hip surgery than those performed by lower-volume surgeons.

  7. The resurfacing history of Mars - A synthesis of digitized, viking-based geology

    Science.gov (United States)

    Tanaka, Kenneth L.; Isbell, Nancy K.; Scott, David H.; Greeley, Ronald; Guest, John E.

    1988-01-01

    A global geologic map series of Mars was digitized at high resolution (1.846 sq km/pixel). It was found that the surface of Mars is predominantly volcanic. A resurfacing history was constructed by estimating the total extent of the geologic units. Eolian resurfacing was prevalent during the Late Amazonian Epoch, affecting 4.9 x 10 to the 6th sq km. It was found that resurfacing rates vary according to the absolute-age scheme used and generally decrease with time. Resurfacing rates were approximately 1000 sq km/yr during the Middle Noachian Epoch, one hundred to several hundred sq km/yr during the Late Noachian to Late Hesperian Epochs, and tens of sq km/yr or less during the Amazonian Period.

  8. Structural-Geometric Functionalization of the Additively Manufactured Prototype of Biomimetic Multispiked Connecting Ti-Alloy Scaffold for Entirely Noncemented Resurfacing Arthroplasty Endoprostheses

    Science.gov (United States)

    Rogala, Piotr; Patalas, Adam

    2017-01-01

    The multispiked connecting scaffold (MSC-Scaffold) prototype, inspired by the biological system of anchorage of the articular cartilage in the periarticular trabecular bone by means of subchondral bone interdigitations, is the essential innovation in fixation of the bone in resurfacing arthroplasty (RA) endoprostheses. The biomimetic MSC‐Scaffold, due to its complex geometric structure, can be manufactured only using additive technology, for example, selective laser melting (SLM). The major purpose of this work is determination of constructional possibilities for the structural-geometric functionalization of SLM‐manufactured MSC‐Scaffold prototype, compensating the reduced ability—due to the SLM technological limitations—to accommodate the ingrowing bone filling the interspike space of the prototype, which is important for the prototype bioengineering design. Confocal microscopy scanning of components of the SLM‐manufactured prototype of total hip resurfacing arthroplasty (THRA) endoprosthesis with the MSC‐Scaffold was performed. It was followed by the geometric measurements of a variety of specimens designed as the fragments of the MSC-Scaffold of both THRA endoprosthesis components. The reduced ability to accommodate the ingrowing bone tissue in the SLM‐manufactured prototypes versus that in the corresponding CAD models has been quantitatively determined. Obtained results enabled to establish a way of compensatory structural‐geometric functionalization, allowing the MSC‐Scaffold adequate redesigning and manufacturing in additive SLM technology. PMID:28785159

  9. Structural-Geometric Functionalization of the Additively Manufactured Prototype of Biomimetic Multispiked Connecting Ti-Alloy Scaffold for Entirely Noncemented Resurfacing Arthroplasty Endoprostheses

    Directory of Open Access Journals (Sweden)

    Ryszard Uklejewski

    2017-01-01

    Full Text Available The multispiked connecting scaffold (MSC-Scaffold prototype, inspired by the biological system of anchorage of the articular cartilage in the periarticular trabecular bone by means of subchondral bone interdigitations, is the essential innovation in fixation of the bone in resurfacing arthroplasty (RA endoprostheses. The biomimetic MSC‐Scaffold, due to its complex geometric structure, can be manufactured only using additive technology, for example, selective laser melting (SLM. The major purpose of this work is determination of constructional possibilities for the structural-geometric functionalization of SLM‐manufactured MSC‐Scaffold prototype, compensating the reduced ability—due to the SLM technological limitations—to accommodate the ingrowing bone filling the interspike space of the prototype, which is important for the prototype bioengineering design. Confocal microscopy scanning of components of the SLM‐manufactured prototype of total hip resurfacing arthroplasty (THRA endoprosthesis with the MSC‐Scaffold was performed. It was followed by the geometric measurements of a variety of specimens designed as the fragments of the MSC-Scaffold of both THRA endoprosthesis components. The reduced ability to accommodate the ingrowing bone tissue in the SLM‐manufactured prototypes versus that in the corresponding CAD models has been quantitatively determined. Obtained results enabled to establish a way of compensatory structural‐geometric functionalization, allowing the MSC‐Scaffold adequate redesigning and manufacturing in additive SLM technology.

  10. [Hip fractures].

    Science.gov (United States)

    Weisová, Drahomíra; Salášek, Martin; Pavelka, Tomáš

    2013-01-01

    Hip fractures are ranked among the frequent injuries. These fractures have been often coupled with high energy trauma in children and in patients with normal bone structure, low energy trauma and osteoporotic fracture (fragility fracture) is typical in elder patients. Hip fractures are divided into five groups: femoral head fracture, femoral neck fracture, pertrochanteric, intertrochateric and subtrochanteric fracture. Surgical treatment is indicated in all patients unless contraindications are present. Long bed rest has been accompanied by a high risk of development of thromboembolic disease, pneumonia and bed sore. Healing in the wrong position and nonunions are often the result of conservative treatment. Screw osteosynthesis is performed in isolated femoral head factures. Three cannulated screws or a DHS plate (dynamic hip screw) are used in fractures of the femoral neck with normal femoral head perfusion, total hip replacement is recommended in elder patients and in case of loss of blood supply of the femoral head. Pertrochanteric and intertrochanteric fractures can be stabilized by the femoral nails (PFN, PFN A, PFH - proximal femoral nail), nails are suitable for minimally invasive insertion and provide higher stability in the shaft, or plates (DHS) designed for stable pertronchanteric and intertrochanteric fractures. Subtrochanteric fractures can be fixed also intramedullary (nails - PFN long, PFN A long) and extramedullary (plates - DCS dynamic condylar screw, proximal femoral LCP - locking compression plate). Open reduction with internal plate fixation is advantageous for pathological fractures, as biopsy sampling can be performed. Hip fracture rehabilitation is integral part of the treatment, including walking on crutches or with a walker with partial weight bearing for at least six weeks.

  11. Assessment of femoral neck fracture risk for a novel proximal epiphyseal hip prosthesis.

    Science.gov (United States)

    Cristofolini, Luca; Juszczyk, Mateusz; Taddei, Fulvia; Field, Richard E; Rushton, Neil; Viceconti, Marco

    2011-07-01

    This study addresses the risk of femoral neck fracture associated with resurfacing hip prostheses. A novel cemented Proximal Epiphyseal Replacement (PER) featuring a short curved stem was investigated. Seven pairs of femurs were in vitro tested. One femur of each pair was randomly assigned for PER implantation. The contralateral femur was tested intact. All femurs were loaded to failure in a validated, physiological configuration. High-speed videos (10,000-12,000 frames/s) were acquired to identify the location of fracture initiation. For comparison, data were included from Birmingham Hip Resurfacing previously tested in an identical fashion (N=3). Relative to the contralateral intact femurs, the failure load of the PER and Birmingham implants was 15.4% higher and 10.0% lower, respectively. In six of the seven PER implants, fracture initiation (neck or inter-trochanteric) was similar to the contralateral intact femurs, suggesting comparable stress distribution. Conversely, fracture initiation in the Birmingham implants occurred at the lateral prosthesis rim, which differed substantially from the intact femurs. No correlation existed between bone quality and strengthening/weakening effect of the PER (failure load of implant as a percentage of intact: R^2=0.067). Conversely, Birmingham implantation weakened the femurs with lower density (R^2=0.92). Therefore, unlike most resurfacing prostheses, the PER seems suitable also for osteoporotic subjects. This study seems to confirm that resurfacing with a Birmingham Hip tends to reduce the strength of the proximal femur. The opposite seemed to happen with the PER, which slightly reduced the risk of neck fracture, also in low-quality bones. Copyright © 2011 Elsevier Ltd. All rights reserved.

  12. Prior image constrained compressed sensing metal artifact reduction (PICCS-MAR): 2D and 3D image quality improvement with hip prostheses at CT colonography

    International Nuclear Information System (INIS)

    Bannas, Peter; Li, Yinsheng; Motosugi, Utaroh; Li, Ke; Chen, Guang-Hong; Lubner, Meghan; Pickhardt, Perry J.

    2016-01-01

    To assess the effect of the prior-image-constrained-compressed-sensing-based metal-artefact-reduction (PICCS-MAR) algorithm on streak artefact reduction and 2D and 3D-image quality improvement in patients with total hip arthroplasty (THA) undergoing CT colonography (CTC). PICCS-MAR was applied to filtered-back-projection (FBP)-reconstructed DICOM CTC-images in 52 patients with THA (unilateral, n = 30; bilateral, n = 22). For FBP and PICCS-MAR series, ROI-measurements of CT-numbers were obtained at predefined levels for fat, muscle, air, and the most severe artefact. Two radiologists independently reviewed 2D and 3D CTC-images and graded artefacts and image quality using a five-point-scale (1 = severe streak/no-diagnostic confidence, 5 = no streak/excellent image-quality, high-confidence). Results were compared using paired and unpaired t-tests and Wilcoxon signed-rank and Mann-Whitney-tests. Streak artefacts and image quality scores for FBP versus PICCS-MAR 2D-images (median: 1 vs. 3 and 2 vs. 3, respectively) and 3D images (median: 2 vs. 4 and 3 vs. 4, respectively) showed significant improvement after PICCS-MAR (all P < 0.001). PICCS-MAR significantly improved the accuracy of mean CT numbers for fat, muscle and the area with the most severe artefact (all P < 0.001). PICCS-MAR substantially reduces streak artefacts related to THA on DICOM images, thereby enhancing visualization of anatomy on 2D and 3D CTC images and increasing diagnostic confidence. (orig.)

  13. Safety and efficacy of high fluence CO2 laser skin resurfacing with a single pass.

    Science.gov (United States)

    Khosh, M M; Larrabee, W F; Smoller, B

    1999-01-01

    Carbon dioxide (CO2) laser skin resurfacing has nearly replaced more traditional methods of superficial skin rejuvenation. Post-treatment erythema is the most common side effect of this method of skin resurfacing. Sublethal thermal damage to the dermis has been proposed as an etiology for post laser erythema. Recent developments in laser resurfacing technology have aimed at minimizing thermal damage to the dermis. To determine depth of skin ablation, extent of thermal injury, and ideal laser parameters for the FeatherTouch laser system. To assess the safety and efficacy of laser resurfacing at high energy fluences with a single pass. Laser resurfacing was performed in the preauricular skin of five patients undergoing rhytidectomy. A total of 60 sites were tested with fluences of 7 to 17 Joules/cm2. Histologic evaluation of excised skin showed maximal thermal injury to be restricted to 60 microns in the papillary dermis. The reticular dermis showed no evidence of injury. Based on these findings, laser resurfacing at 17 J/cm2 (70 watts) was performed on 30 patients (in the periorbital area, a maximum of 9 J/cm2 or 36 watts was used). Follow up ranged between 12 and 18 months. Based on histologic comparison of average and high fluence laser resurfacing, high fluence laser resurfacing did not cause added thermal damage to the reticular dermis. In the clinical group, no major complications such as scarring, scleral show, infection or ectropion were encountered. Transient hyperpigmentation was noted in three patients. Overall patient satisfaction was good to excellent. Post-treatment erythema lasted an average of 4 weeks. We conclude that CO2 laser resurfacing of the face (excluding the periorbital region) can be performed safely and effectively, with the FeatherTouch laser, at 17 J/cm2 with one pass. In our group of patients, laser resurfacing with a single pass at 17 J/cm2 caused less post-operative erythema than two or more passes at 9 J/cm2.

  14. Automatic assessment of volume asymmetries applied to hip abductor muscles in patients with hip arthroplasty

    Science.gov (United States)

    Klemt, Christian; Modat, Marc; Pichat, Jonas; Cardoso, M. J.; Henckel, Joahnn; Hart, Alister; Ourselin, Sebastien

    2015-03-01

    Metal-on-metal (MoM) hip arthroplasties have been utilised over the last 15 years to restore hip function for 1.5 million patients worldwide. Althoug widely used, this hip arthroplasty releases metal wear debris which lead to muscle atrophy. The degree of muscle wastage differs across patients ranging from mild to severe. The longterm outcomes for patients with MoM hip arthroplasty are reduced for increasing degrees of muscle atrophy, highlighting the need to automatically segment pathological muscles. The automated segmentation of pathological soft tissues is challenging as these lack distinct boundaries and morphologically differ across subjects. As a result, there is no method reported in the literature which has been successfully applied to automatically segment pathological muscles. We propose the first automated framework to delineate severely atrophied muscles by applying a novel automated segmentation propagation framework to patients with MoM hip arthroplasty. The proposed algorithm was used to automatically quantify muscle wastage in these patients.

  15. Comparisons of slice-encoding metal artifact correction and view-angle tilting magnetic resonance imaging and traditional digital radiography in evaluating chronic hip pain after total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Yimin Ma

    2018-01-01

    Translational potential of this article: The main objective of this research was to show that MR sequences from the SEMAC-VAT TSE prototype provide a significant advantage at detecting lesions in patients after THA because of the excellent soft-tissue resolution of the MR imaging. SEMAC-VAT MR can evaluate chronic hip pain after THA and determine the cause, which can help the clinician decide on whether a surgical revision is needed.

  16. Potential role of resurfacing Subtropical Underwater in ENSO evolution

    Science.gov (United States)

    Qu, T.; Chi, J.

    2017-12-01

    Results from a model of the Estimating the Circulation and Climate of the Ocean (ECCO) have shown that the resurfacing of high salinity Subtropical Underwater contributes to the sea surface salinity variability in the equatorial Pacific. On interannual time scale, this contribution can account for as much as 25% of the surface freshwater flux anomalies and is believed to play a role in ENSO evolution. Having these results in mind, this study investigates the surface salinity budget and its primary controls in the equatorial Pacific using ECCO output for the period 1993-2016. Particular attention is paid to 2014/2015 and 2015/2016. Preliminary analyses of the model results suggest that enhanced subsurface processes and in particular enhanced entrainment of Subtropical Underwater are primarily responsible for the positive sea surface salinity anomalies in the central equatorial Pacific during 2014/2015, which represents an opposite phase of El Niño. These subsurface processes weakened during 2015/2016, diretly contributing to the development of the 2015/2016 El Niño. The mechanisms controlling these subsurface processes are discussed.

  17. Histological evaluation of vertical laser channels from ablative fractional resurfacing

    DEFF Research Database (Denmark)

    Skovbølling Haak, Christina; Illes, Monica; Paasch, Uwe

    2011-01-01

    Ablative fractional resurfacing (AFR) represents a new treatment potential for various skin conditions and new laser devices are being introduced. It is important to gain information about the impact of laser settings on the dimensions of the created laser channels for obtaining a safe...... and efficient treatment outcome. The aim of this study was to establish a standard model to document the histological tissue damage profiles after AFR and to test a new laser device at diverse settings. Ex vivo abdominal pig skin was treated with a MedArt 620, prototype fractional carbon dioxide (CO(2)) laser...... measurements for each laser setting (n = 28). AFR created cone-shaped laser channels. Ablation depths varied from reaching the superficial dermis (2 mJ, median 41 μm) to approaching the subcutaneous fat (144 mJ, median 1,943 μm) and correlated to the applied energy levels in an approximate linear relation (r(2...

  18. Females with Unexplained Joint Pain Following Total Joint Arthroplasty Exhibit a Higher Rate and Severity of Hypersensitivity to Implant Metals Compared with Males: Implications of Sex-Based Bioreactivity Differences.

    Science.gov (United States)

    Caicedo, Marco S; Solver, Edward; Coleman, Latasha; Jacobs, Joshua J; Hallab, Nadim J

    2017-04-19

    Recent studies indicate that females demonstrate an increased risk of experiencing adverse local tissue reactions, aseptic loosening, and revision after primary metal-on-metal hip resurfacing arthroplasty compared with males; the underlying biological mechanisms responsible for sex discrepancies in implant failure remain unclear. In addition to anatomical and biomechanical sex differences, there may be inherent immunological disparities that predispose females to more aggressive adaptive immune reactivity to implant debris, i.e., metal sensitivity. In this retrospective study, we analyzed sex-associated rates and levels of metal sensitization in 1,038 male and 1,575 female subjects with idiopathic joint pain following total joint arthroplasty (TJA) who were referred for in vitro metal-sensitivity testing. Females demonstrated a significantly higher rate and severity of metal sensitization compared with males. The median lymphocyte stimulation index (SI) among males was 2.8 (mean, 5.4; 95% confidence interval [CI], 4.9 to 6.0) compared with 3.5 (mean, 8.2; 95% CI, 7.4 to 9.0) among females (p metal-sensitivity testing, females exhibited a higher level of pain and demonstrated a higher rate and severity (as measured by lymphocyte SI) of metal sensitization compared with males. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  19. Hip Replacement Surgery

    Science.gov (United States)

    ... Initiative Breadcrumb Home Health Topics English Español Hip Replacement Surgery Basics In-Depth Download Download EPUB Download ... What is it? Points To Remember About Hip Replacement Surgery Hip replacement surgery removes damaged or diseased ...

  20. Hip replacement - discharge

    Science.gov (United States)

    ... discharge; Total hip replacement - discharge; Hip hemiarthroplasty - discharge; Osteoarthritis - hip replacement discharge ... such as downhill skiing or contact sports like football and soccer. But you should be able to ...

  1. Hip fracture - discharge

    Science.gov (United States)

    ... Philadelphia, PA: Elsevier; 2017:chap 55. Read More Broken bone Hip fracture surgery Hip pain Leg MRI scan Osteoporosis - overview Patient Instructions Getting your home ready - knee or hip surgery Osteomyelitis - discharge Review ...

  2. Low-dose CT imaging of a total hip arthroplasty phantom using model-based iterative reconstruction and orthopedic metal artifact reduction

    Energy Technology Data Exchange (ETDEWEB)

    Wellenberg, R.H.H.; Streekstra, G.J.; Maas, M. [Academic Medical Center, Department of Radiology, Amsterdam (Netherlands); Boomsma, M.F.; Osch, J.A.C. van [Department of Radiology, Zwolle (Netherlands); Vlassenbroek, A. [Philips Medical Systems, Brussels (Belgium); Milles, J. [Philips Medical Systems, Eindhoven (Netherlands); Edens, M.A. [Department of Innovation and Science, Zwolle (Netherlands); Slump, C.H. [University of Twente, MIRA Institute for Biomedical Technology and Technical Medicine, Enschede (Netherlands)

    2017-05-15

    To compare quantitative measures of image quality, in terms of CT number accuracy, noise, signal-to-noise-ratios (SNRs), and contrast-to-noise ratios (CNRs), at different dose levels with filtered-back-projection (FBP), iterative reconstruction (IR), and model-based iterative reconstruction (MBIR) alone and in combination with orthopedic metal artifact reduction (O-MAR) in a total hip arthroplasty (THA) phantom. Scans were acquired from high- to low-dose (CTDI{sub vol}: 40.0, 32.0, 24.0, 16.0, 8.0, and 4.0 mGy) at 120- and 140- kVp. Images were reconstructed using FBP, IR (iDose{sup 4} level 2, 4, and 6) and MBIR (IMR, level 1, 2, and 3) with and without O-MAR. CT number accuracy in Hounsfield Units (HU), noise or standard deviation, SNRs, and CNRs were analyzed. The IMR technique showed lower noise levels (p < 0.01), higher SNRs (p < 0.001) and CNRs (p < 0.001) compared with FBP and iDose{sup 4} in all acquisitions from high- to low-dose with constant CT numbers. O-MAR reduced noise (p < 0.01) and improved SNRs (p < 0.01) and CNRs (p < 0.001) while improving CT number accuracy only at a low dose. At the low dose of 4.0 mGy, IMR level 1, 2, and 3 showed 83%, 89%, and 95% lower noise values, a factor 6.0, 9.2, and 17.9 higher SNRs, and 5.7, 8.8, and 18.2 higher CNRs compared with FBP respectively. Based on quantitative analysis of CT number accuracy, noise values, SNRs, and CNRs, we conclude that the combined use of IMR and O-MAR enables a reduction in radiation dose of 83% compared with FBP and iDose{sup 4} in the CT imaging of a THA phantom. (orig.)

  3. MOM Failure Modes: An In-Depth Look at Metal Ions and Implant Wear

    Directory of Open Access Journals (Sweden)

    Tom Donaldson, MD

    2014-03-01

    Full Text Available Contemporary MOM bearings (large-diameter heads offered the perceived benefits of much greater range of motion and greater stability with reduced risk of impingement and dislocation. A variety of design and Both positive [1-3] and negative reports [4-8] have now emerged with regard to total hip arthroplasty (THA and resurfacing arthroplasty. As a result, there has been an avalanche of studies focused on critical issues such as: surgical positioning, shallow cups (face angles 144-170° [9-11] and “edge loading”. [5,7,12-17] However, there are several, possibly synergistic, risk scenarios that could trigger adverse MOM wear and very little progress has been made in understanding such interacting parameters. In an effort to understand the role of metal ion analysis and how it relates to revision surgery and implant wear, selected MOM revised cases were reviewed [28]. Retrieval data was included in conjunction with metal ion analyses and intraoperative observations to determine various failure modes.  We suggest MOM devices that are well fixed but fail after 2 years can be classified into one of six modes: (i normal, (ii allergic reaction, (iii 3rd body wear, (iv repetitive subluxation with metal impingement, (v multi-directional subluxation with soft tissue impingement, and (vi repetitive subluxation with soft tissue impingement.

  4. Partial resurfacing with varus osteotomy for an osteochondral defect of the femoral head

    NARCIS (Netherlands)

    van Stralen, Renée A.; Haverkamp, Daniël; van Bergen, Christiaan J. A.; Eijer, Henk

    2009-01-01

    Osteochondral defects of the femoral head represent a major challenge and various modern treatment options exist. We report a 16-year-old male with a large (3 x 3cm) osteochondral defect of the femoral head that was treated with a partial resurfacing prosthesis combined with a high varus osteotomy,

  5. The Plains of Aphrodite: Geohistory and Modes of Volcanic Resurfacing, Venus

    Science.gov (United States)

    Hansen, V. L.; Young, D. A.; Lang, N. P.; Bleamaster, B. F., III

    2002-03-01

    Geologic mapping of four contiguous VMAPs that cross the planitiae of Northern Aphrodite provides clues for plains surface evolution. Two modes of resurfacing emerge: relatively long and extensive flows sourced dominantly from coronae and, formation of a thin, lacey volcanic shield layer.

  6. Evaluation of periprosthetic bone mineral density and postoperative migration of humeral head resurfacing implants

    DEFF Research Database (Denmark)

    Mechlenburg, Inger; Klebe, Thomas Martin; Døssing, Kaj Verner

    2014-01-01

    BACKGROUND: Implant migration, bone mineral density (BMD), length of glenohumeral offset (LGHO), and clinical results were compared for the Copeland (Biomet Inc, Warsaw, IN, USA) and the Global C.A.P. (DePuy Int, Warsaw, IN, USA) humeral head resurfacing implants (HHRIs). METHODS: The study...

  7. Hip prostheses in young adults. Surface prostheses and short-stem prostheses.

    Science.gov (United States)

    Gallart, X; Riba, J; Fernández-Valencia, J A; Bori, G; Muñoz-Mahamud, E; Combalia, A

    The poor results obtained in young patients when using a conventional prosthesis led to the resurgence of hip resurfacing to find less invasive implants for the bone. Young patients present a demand for additional activity, which makes them a serious challenge for the survival of implants. In addition, new information technologies contribute decisively to the preference for non-cemented prostheses. Maintaining quality of life, preserving the bone and soft tissues, as well as achieving a very stable implant, are the goals of every hip orthopaedic surgeon for these patients. The results in research point to the use of smaller prostheses, which use the metaphyseal zone more and less the diaphyseal zone, and hence the large number of the abovementioned short stem prostheses. Both models are principally indicated in the young adult. Their revision should be a more simple operation, but this is only true for hip resurfacing, not for short stems. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Should we resurface the patella in total knee replacement? Experience with the Nex Gen prothesis.

    Science.gov (United States)

    Tabutin, J; Banon, F; Catonne, Y; Grobost, J; Tessier, J L; Tillie, B

    2005-10-01

    Patellar resurfacing is a controversial issue in primary total knee replacement. So, we took advantage of a large study to try and answer this question. An open prospective multicentric study was conducted about the outcome of the Nex Gen Total Knee prosthesis with clinical and radiological follow-up at regular intervals (1, 2 and 5 years). The data were centrally collected and analyzed by independent observers. A total of whole 5,915 cases were included (487 in the French group); incidences of patello-femoral pain were observed in both French and international groups and compared between cases with or without resurfaced patellae. Only osteoarthritic cases were selected for this particular study. Statistical analysis was performed using a Pearson's Chi-square test with a 95% confidence interval. The frequency of preoperative pain was significantly higher in the French group; 85.1% versus 66.6% (p<0.05). No patello-femoral pain appeared in preoperatively painless patients in the French group. The frequency of lateral patellar release was similar in both groups. 35.7% of the patellae were resurfaced in the international group versus 98.8% in the French one. At 2 years, patello-femoral pain was observed in 6.3% of cases in the former group versus 0.7% in the latter one. The risk of having patello-femoral pain was 9.45 times higher in the international group. When considering resurfaced cases in both groups the risk of having anterior knee pain was not significantly different (p=0.35). In the French group, one case out of nine (11.1%) with patello-femoral pain had not been resurfaced, while 129 cases out of 151 (85.4%) had not had a resurfacing in the international group. This emphasizes the effect of patellar implant on pain. Although patello-femoral pain is multifactorial, this analysis tool is powerful in getting rid of the "center effect " (cf Swedish register). Even if a longer follow-up for confirmation is needed, our data favor patellar resurfacing with this

  9. Wear mechanisms in ceramic hip implants.

    Science.gov (United States)

    Slonaker, Matthew; Goswami, Tarun

    2004-01-01

    The wear in hip implants is one of the main causes for premature hip replacements. The wear affects the potential life of the prosthesis and subsequent removals of in vivo implants. Therefore, the objective of this article is to review various joints that show lower wear rates and consequently higher life. Ceramics are used in hip implants and have been found to produce lower wear rates. This article discusses the advantages and disadvantages of ceramics compared to other implant materials. Different types of ceramics that are being used are reviewed in terms of the wear characteristics, debris released, and their size together with other biological factors. In general, the wear rates in ceramics were lower than that of metal-on-metal and metal-on-polyethylene combinations.

  10. Fractional CO 2 laser resurfacing as monotherapy in the treatment of atrophic facial acne scars

    Directory of Open Access Journals (Sweden)

    Imran Majid

    2014-01-01

    Full Text Available Background: While laser resurfacing remains the most effective treatment option for atrophic acne scars, the high incidence of post-treatment adverse effects limits its use. Fractional laser photothermolysis attempts to overcome these limitations of laser resurfacing by creating microscopic zones of injury to the dermis with skip areas in between. Aim: The aim of the present study is to assess the efficacy and safety of fractional CO 2 laser resurfacing in atrophic facial acne scars. Materials and Methods: Sixty patients with moderate to severe atrophic facial acne scars were treated with 3-4 sessions of fractional CO 2 laser resurfacing at 6-week intervals. The therapeutic response to treatment was assessed at each follow up visit and then finally 6 months after the last laser session using a quartile grading scale. Response to treatment was labelled as ′excellent′ if there was >50% improvement in scar appearance and texture of skin on the grading scale while 25-50% response and <25% improvement were labelled as ′good′ and ′poor′ response, respectively. The overall satisfaction of the patients and any adverse reactions to the treatment were also noted. Results: Most of the patients showed a combination of different morphological types of acne scars. At the time of final assessment 6 months after the last laser session, an excellent response was observed in 26 patients (43.3% while 15 (25% and 19 patients (31.7% demonstrated a good and poor response respectively. Rolling and superficial boxcar scars responded the best while pitted scars responded the least to fractional laser monotherapy. The commonest reported adverse effect was transient erythema and crusting lasting for an average of 3-4 and 4-6 days, respectively while three patients developed post-inflammatory pigmentation lasting for 8-12 weeks. Conclusions: Fractional laser resurfacing as monotherapy is effective in treating acne scars especially rolling and superficial boxcar

  11. Incidence of Heterotopic Ossification after Surface and Conventional Total Hip Arthroplasty: A Comparative Study Using Anterolateral Approach and Indomethacin Prophylaxis

    Directory of Open Access Journals (Sweden)

    Dario Regis

    2013-01-01

    Full Text Available The incidence and severity of heterotopic ossification (HO in two homogeneous groups of patients that received surface replacement arthroplasty (SRA and conventional total hip arthroplasty (THA were evaluated retrospectively. Thirty-nine patients undergoing 42 hip resurfacing procedures and 41 primary cementless THAs through an anterolateral approach received a 10-day course of 150 mg/die of indomethacin postoperatively. The median surgical time was 190 minutes and 156 minutes, respectively (. At a minimum 1-year followup, the development of HO was assessed on standard X-ray using Brooker grading. Ectopic bone formation was detected in five cases (11.9%, two Brooker grade I and three grade II in the SRA group and in 14 hips (34.1%, 12 grade I and two grade II treated with conventional THA, but the difference was not significant (. No clinically relevant periprosthetic ossification (Brooker III or IV occurred in both groups. Although the difference was not statistically significant, the incidence of HO after SRA was lower than conventional THA. More extensive soft tissue trauma, bone debris, and longer operative time in hip resurfacing are not likely to be absolute risk factors for HO. Further investigations including larger patient populations are needed to confirm these findings.

  12. Hip joint replacement - slideshow

    Science.gov (United States)

    ... medlineplus.gov/ency/presentations/100006.htm Hip joint replacement - series—Normal anatomy To use the sharing features ... M. Editorial team. Related MedlinePlus Health Topics Hip Replacement A.D.A.M., Inc. is accredited by ...

  13. Hip replacement - precautions

    Science.gov (United States)

    ... page, please enable JavaScript. After you have hip replacement surgery, you will need to be careful how ... to Expect at Home After you have hip replacement surgery, you will need to be careful how ...

  14. The other hip in unilateral hip dysplasia

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Rømer, Lone; Søballe, Kjeld

    2006-01-01

    with apparently unilateral right developmental dysplasia (left hip center-edge angles greater than 20 degrees), 26 patients with apparently unilateral left developmental dysplasia (right hip center-edge angles greater than 20 degrees), 68 patients with bilateral developmental dysplasia, and 34 patients...... "gold" standard]). See the Guidelines for Authors for a complete description of levels of evidence....

  15. HIPs at Ten

    Science.gov (United States)

    Kuh, George; O'Donnell, Ken; Schneider, Carol Geary

    2017-01-01

    2017 is the anniversary of the introduction of what are now commonly known as high-impact practices (HIPs). Many of the specific activities pursued under the HIPs acronym have been around in some form for decades, such as study abroad, internships, and student-faculty research. It was about ten years ago that, after conferring HIPs at Ten with…

  16. Bursitis of the Hip

    Science.gov (United States)

    ... difficile (C. diff.) InfectionHerpes Home Diseases and Conditions Bursitis of the Hip Condition Bursitis of the Hip Share Print Table of Contents1. ... Prevention5. Treatment6. Everyday Life7. Questions8. Resources What is bursitis of the hip? Bursitis is the painful swelling ...

  17. The Hip Restoration Algorithm

    Science.gov (United States)

    Stubbs, Allston Julius; Atilla, Halis Atil

    2016-01-01

    Summary Background Despite the rapid advancement of imaging and arthroscopic techniques about the hip joint, missed diagnoses are still common. As a deep joint and compared to the shoulder and knee joints, localization of hip symptoms is difficult. Hip pathology is not easily isolated and is often related to intra and extra-articular abnormalities. In light of these diagnostic challenges, we recommend an algorithmic approach to effectively diagnoses and treat hip pain. Methods In this review, hip pain is evaluated from diagnosis to treatment in a clear decision model. First we discuss emergency hip situations followed by the differentiation of intra and extra-articular causes of the hip pain. We differentiate the intra-articular hip as arthritic and non-arthritic and extra-articular pain as surrounding or remote tissue generated. Further, extra-articular hip pain is evaluated according to pain location. Finally we summarize the surgical treatment approach with an algorithmic diagram. Conclusion Diagnosis of hip pathology is difficult because the etiologies of pain may be various. An algorithmic approach to hip restoration from diagnosis to rehabilitation is crucial to successfully identify and manage hip pathologies. Level of evidence: V. PMID:28066734

  18. Standard guidelines of care: CO 2 laser for removal of benign skin lesions and resurfacing

    Directory of Open Access Journals (Sweden)

    Krupashankar D

    2008-03-01

    Full Text Available Resurfacing is a treatment to remove acne and chicken pox scars, and changes in the skin due to ageing. Machines : Both ablative and nonablative lasers are available for use. CO 2 laser is the gold standard in ablative lasers. Detailed knowledge of the machines is essential. Indications for CO 2 laser: Therapeutic indications: Actinic and seborrheic keratosis, warts, moles, skin tags, epidermal and dermal nevi, vitiligo blister and punch grafting, rhinophyma, sebaceous hyperplasia, xanthelasma, syringomas, actinic cheilitis angiofibroma, scar treatment, keloid, skin cancer, neurofibroma and diffuse actinic keratoses. CO 2 laser is not recommended for the removal of tattoos. Aesthetic indications: Resurfacing for acne, chicken pox and surgical scars, periorbital and perioral wrinkles, photo ageing changes, facial resurfacing. Physicians′ qualifications: Any qualified dermatologist (DVD or MD may practice CO 2 laser. The dermatologist should possess postgraduate qualification in dermatology and should have had specific hands-on training in lasers either during postgraduation or later at a facility which routinely performs laser procedures under a competent dermatologist/plastic surgeon, who has experience and training in using lasers. For the use of CO 2 lasers for benign growths, a full day workshop is adequate. As parameters may vary in different machines, specific training with the available machine at either the manufacturer′s facility or at another centre using the machine is recommended. Facility: CO 2 lasers can be used in the dermatologist′s minor procedure room for the above indications. However, when used for full-face resurfacing, the hospital operation theatre or day care facility with immediate access to emergency medical care is essential. Smoke evacuator is mandatory. Preoperative counseling and Informed consent Detailed counseling with respect to the treatment, desired effects, possible postoperative complications, should be

  19. [Avascular necrosis of the hip - diagnosis and treatment].

    Science.gov (United States)

    Drescher, W; Pufe, T; Smeets, R; Eisenhart-Rothe, R V; Jäger, M; Tingart, M

    2011-04-01

    Femoral head necrosis is an ischaemic bone necrosis of traumatic or nontraumatic pathogenesis which can lead to hip joint destruction in young age. It is today the indication for 10 % of all the total hip joint replacements. Known aetiologies of nontraumatic femoral head necrosis are alcoholism, steroids, sickle cell anaemia, caisson, and Gaucher's disease. Further risk factors are chemotherapy, chronic inflammatory bowel disease, systemic lupus erythematosus, and multiple sclerosis, in which also steroids are involved. Gravidity is another risk factor, but still idiopathic pathogenesis is found. In diagnosis, the ARCO-classification of the Association for the Research of Osseous Circulation is essential. While stage 0 can only be found histologically, the reversible early stage 1 shows MR signal changes. In the irreversible early stage 2, first native x-ray changes are seen as lower radiolucency reflects new bone apposition on dead trabeculae. In stage 3, subchondral fracture follows, and in stage 4 secondary arthritis of the hip. Established therapy in stage 1 is core decompression, physiotherapy, and more and more also bisphosphonates. Sufficient data to support extracorporeal shock wave therapy are still lacking. Stem cell therapy seems to be a promising new therapy method in stage 2. In stage 2 and 3 mainly proximal femoral osteotomies and (non)vascularised bone transplantation are performed. In stage 4, depending on size and location of the necrotic zone and pathology of the adjacent bone, resurfacing or short stem hip arthroplasty can be performed. However, conventional THA is still golden standard. The problem and challenge, however, is the often young patient age in femoral head necrosis. Especially chemotherapy-associated osteonecrosis in leukaemia is found in patients in their second decade of life. Therefore, the hip should be preserved as long as possible. © Georg Thieme Verlag KG Stuttgart · New York.

  20. "Active" and "Passive" Lava Resurfacing Processes on Io: A Comparative Study of Loki Patera and Prometheus

    Science.gov (United States)

    Davies, A. G.; Matson, D. L.; Leone, G.; Wilson, L.; Keszthelyi, L. P.

    2004-01-01

    Studies of Galileo Near Infrared Mapping Spectrometer (NIMS) data and ground based data of volcanism at Prometheus and Loki Patera on Io reveal very different mechanisms of lava emplacement at these two volcanoes. Data analyses show that the periodic nature of Loki Patera s volcanism from 1990 to 2001 is strong evidence that Loki s resurfacing over this period resulted from the foundering of a crust on a lava lake. This process is designated passive , as there is no reliance on sub-surface processes: the foundering of the crust is inevitable. Prometheus, on the other hand, displays an episodicity in its activity which we designate active . Like Kilauea, a close analog, Prometheus s effusive volcanism is dominated by pulses of magma through the nearsurface plumbing system. Each system affords views of lava resurfacing processes through modelling.

  1. Outcome, revision rate and indication for revision following resurfacing hemiarthroplasty for osteoarthritis of the shoulder

    DEFF Research Database (Denmark)

    Rasmussen, J V; Polk, A; Sorensen, A K

    2014-01-01

    In this study, we evaluated patient-reported outcomes, the rate of revision and the indications for revision following resurfacing hemiarthroplasty of the shoulder in patients with osteoarthritis. All patients with osteoarthritis who underwent primary resurfacing hemiarthroplasty and reported...... to the Danish Shoulder Arthroplasty Registry (DSR), between January 2006 and December 2010 were included. There were 772 patients (837 arthroplasties) in the study. The Western Ontario Osteoarthritis of the Shoulder (WOOS) index was used to evaluate patient-reported outcome 12 months (10 to 14) post......-operatively. The rates of revision were calculated from the revisions reported to the DSR up to December 2011 and by checking deaths with the Danish National Register of Persons. A complete questionnaire was returned by 688 patients (82.2%). The mean WOOS was 67 (0 to 100). A total of 63 hemiarthroplasties (7...

  2. SU-G-IeP2-03: Comparison of Dose Calculation On MAR (metal Artifact Reduction) and Non-MAR Datasets for Pelvic Patients with Hip Prosthesis and Head and Neck Patients with Dental Filling

    Energy Technology Data Exchange (ETDEWEB)

    Huang, V; Kohli, K [BC Cancer Agency, Surrey, BC (United Kingdom)

    2016-06-15

    Purpose: Metal artifact reduction (MAR) software in computed tomography (CT) was previously evaluated with phantoms demonstrating the algorithm is capable of reducing metal artifacts without affecting the overall image quality. The goal of this study is to determine the dosimetric impact when calculating with CT datasets reconstructed with and without MAR software. Methods: Twelve head and neck cancer patients with dental fillings and four pelvic cancer patients with hip prosthesis were scanned with a GE Optima RT 580 CT scanner. Images were reconstructed with and without the MAR software. 6MV IMRT and VMAT plans were calculated with AAA on the MAR dataset until all constraints met our clinic’s guidelines. Contours from the MAR dataset were copied to the non-MAR dataset. Next, dose calculation on the non-MAR dataset was performed using the same field arrangements and fluence as the MAR plan. Conformality index, D99% and V100% to PTV were compared between MAR and non-MAR plans. Results: Differences between MAR and non-MAR plans were evaluated. For head and neck plans, the largest variations in conformality index, D99% and V100% were −3.8%, −0.9% and −2.1% respectively whereas for pelvic plans, the biggest discrepancies were −32.7%, −0.4% and -33.5% respectively. The dosimetric impact from hip prosthesis is greater because it produces more artifacts compared to dental fillings. Coverage to PTV can increase or decrease depending on the artifacts since dark streaks reduce the HU whereas bright streaks increase the HU. In the majority of the cases, PTV dose in the non-MAR plans is higher than MAR plans. Conclusion: With the presence of metals, MAR algorithm can allow more accurate delineation of targets and OARs. Dose difference between MAR and non-MAR plans depends on the proximity of the organ to the high density material, the streaking artifacts and the beam arrangements of the plan.

  3. SU-G-IeP2-03: Comparison of Dose Calculation On MAR (metal Artifact Reduction) and Non-MAR Datasets for Pelvic Patients with Hip Prosthesis and Head and Neck Patients with Dental Filling

    International Nuclear Information System (INIS)

    Huang, V; Kohli, K

    2016-01-01

    Purpose: Metal artifact reduction (MAR) software in computed tomography (CT) was previously evaluated with phantoms demonstrating the algorithm is capable of reducing metal artifacts without affecting the overall image quality. The goal of this study is to determine the dosimetric impact when calculating with CT datasets reconstructed with and without MAR software. Methods: Twelve head and neck cancer patients with dental fillings and four pelvic cancer patients with hip prosthesis were scanned with a GE Optima RT 580 CT scanner. Images were reconstructed with and without the MAR software. 6MV IMRT and VMAT plans were calculated with AAA on the MAR dataset until all constraints met our clinic’s guidelines. Contours from the MAR dataset were copied to the non-MAR dataset. Next, dose calculation on the non-MAR dataset was performed using the same field arrangements and fluence as the MAR plan. Conformality index, D99% and V100% to PTV were compared between MAR and non-MAR plans. Results: Differences between MAR and non-MAR plans were evaluated. For head and neck plans, the largest variations in conformality index, D99% and V100% were −3.8%, −0.9% and −2.1% respectively whereas for pelvic plans, the biggest discrepancies were −32.7%, −0.4% and -33.5% respectively. The dosimetric impact from hip prosthesis is greater because it produces more artifacts compared to dental fillings. Coverage to PTV can increase or decrease depending on the artifacts since dark streaks reduce the HU whereas bright streaks increase the HU. In the majority of the cases, PTV dose in the non-MAR plans is higher than MAR plans. Conclusion: With the presence of metals, MAR algorithm can allow more accurate delineation of targets and OARs. Dose difference between MAR and non-MAR plans depends on the proximity of the organ to the high density material, the streaking artifacts and the beam arrangements of the plan.

  4. Can gait deviation index be used efectively for the evaluation of gait pathology in total hip arthroplasty

    DEFF Research Database (Denmark)

    Jensen, Carsten; Rosenlund, Signe; Nielsen, Dennis Brandborg

    In this poster, the Gait Deviation Index (GDI) was used as a convenient method to evaluate pre-to-postoperative gait quality changes after total hip arthroplasty and identify factors which might be predictive of outcome. Design: Three-dimensional gait data from a randomized clinical trial was used...... to determine changes in gait quality in participants walking at self-selected speed. Upon completion of the first assessment, the participants were randomly assigned to either resurfacing hip arthroplasty or conventional hip arthroplasty. The outcome was changes in overall gait quality measured with GDI during...... limbs; 0.3 [95%CI: -2.3 to 1.7]. However, the score for the two groups (pooled data) improved after surgery by 4.4 [95%CI: 1.8 to 7.0]. The single level regression analysis identified the preoperative GDI score as a strong predictor of outcome (p

  5. Crater density differences: Exploring regional resurfacing, secondary crater populations, and crater saturation equilibrium on the moon

    Science.gov (United States)

    Povilaitis, R Z; Robinson, M S; van der Bogert, C H; Hiesinger, Harald; Meyer, H M; Ostrach, Lillian

    2017-01-01

    The global population of lunar craters >20 km in diameter was analyzed by Head et al., (2010) to correlate crater distribution with resurfacing events and multiple impactor populations. The work presented here extends the global crater distribution analysis to smaller craters (5–20 km diameters, n = 22,746). Smaller craters form at a higher rate than larger craters and thus add granularity to age estimates of larger units and can reveal smaller and younger areas of resurfacing. An areal density difference map generated by comparing the new dataset with that of Head et al., (2010) shows local deficiencies of 5–20 km diameter craters, which we interpret to be caused by a combination of resurfacing by the Orientale basin, infilling of intercrater plains within the nearside highlands, and partial mare flooding of the Australe region. Chains of 5–30 km diameter secondaries northwest of Orientale and possible 8–22 km diameter basin secondaries within the farside highlands are also distinguishable. Analysis of the new database indicates that craters 57–160 km in diameter across much of the lunar highlands are at or exceed relative crater densities of R = 0.3 or 10% geometric saturation, but nonetheless appear to fit the lunar production function. Combined with the observation that small craters on old surfaces can reach saturation equilibrium at 1% geometric saturation (Xiao and Werner, 2015), this suggests that saturation equilibrium is a size-dependent process, where large craters persist because of their resistance to destruction, degradation, and resurfacing.

  6. Comparison of four different lasers for acne scars: Resurfacing and fractional lasers.

    Science.gov (United States)

    You, Hi-Jin; Kim, Deok-Woo; Yoon, Eul-Sik; Park, Seung-Ha

    2016-04-01

    Acne scars are common and cause cosmetic problems. There is a multitude of treatment options for acne scars, including dermabrasion, chemical peeling, and fillers, but the advent of laser technology has greatly improved the treatment of acne scars. Although several laser systems are available, studies comparing their efficacy are limited. This study compares the results of treatments using resurfacing (carbon dioxide, CO2; erbium-doped yttrium aluminum garnet, Er:YAG) versus fractional (nonablative fractional laser, NAFL; ablative fractional laser, AFL) lasers. A retrospective photographic analysis of 58 patients who underwent laser treatment for facial atrophic acne scars was performed. Clinical improvement was assessed by six blinded investigators with a scale graded from 0 to 10. Adverse events were also noted. Mean improvement scores of the CO2, Er:YAG, NAFL, and AFL groups were 6.0, 5.8, 2.2, and 5.2, respectively. The NAFL group showed a significantly lower score than the other groups. The mean number of treatments was significantly greater in the fractional laser groups than in the resurfacing laser groups. The resurfacing laser groups had a prolonged recovery period and high risk of complications. The Er:YAG laser caused less erythema or pigmentation compared to the CO2 laser. Although the CO2 laser, Er:YAG laser, and AFL improved the acne scars, the CO2 laser had a greater downtime. Three consecutive AFL treatments are as effective as a single treatment with resurfacing lasers, with shorter social downtime periods and less adverse effects. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  7. Scar resurfacing with high-energy, short-pulsed and flashscanning carbon dioxide lasers.

    Science.gov (United States)

    Bernstein, L J; Kauvar, A N; Grossman, M C; Geronemus, R G

    1998-01-01

    Scars have a significant effect on a person's physical and social being. Many treatment modalities for scar improvement such as surgical scar revision, electrosurgical planing, chemical peeling, filler substance implantation, and dermabrasion have been developed. Recently, the resurfacing carbon dioxide (CO2) laser systems have proven to be a useful and safe treatment in the treatment of facial rhytides and acne scarring. The purpose of this study was to evaluate the resurfacing CO2 lasers in the treatment of various surgical, traumatic, acne, and varicella scars. Thirty subjects, aging between 14 and 84 years, with surgical, traumatic, acne, or varicella scars were evaluated. Two types of resurfacing laser systems were utilized in this study, a high-energy, short-pulsed CO2 laser and a continuous wave CO2 laser with an optico-mechanical computer flash-scanner. Post-surgical scars were treated with laser resurfacing between 4 and 6 weeks after scar formation. Traumatic, acne, and varicella scars were treated after scar maturation (range, 1-10 years). Scar improvement was evaluated by photographic analysis of before and after images by four independent health care workers using a quartile scale of improvement ( 75%) as well as optical profilometry using silicone surface impressions in 12 scars. Twenty of 24 surgical scars had greater than 75% improvement, and 24 of 24 had greater than 50% improvement by photographic analysis. All six traumatic, acne and varicella scars had greater than 50% improvement. Optical profilometry and surface topography maps reveal a significant flattening of related and depressed scars. The high-energy, short-pulsed CO2 laser and the continuous wave CO2 laser with flash-scanning attachment are safe and effective as a treatment modality for scar revision. In general, elevated scars improve more dramatically than depressed scars.

  8. A new patient classification for laser resurfacing and peels: predicting responses, risks, and results.

    Science.gov (United States)

    Fanous, Nabil

    2002-01-01

    Traditional classifications for skin treatment modalities are based on skin characteristics, the most important being skin color. Other factors are considered as well, such as oiliness, thickness, pathology, and sensitivity. While useful, these classifications are occasionally inadequate in predicting and explaining the outcome of some peels, dermabrasions, or laser resurfacing procedures. Why, for example, would a Korean patient with a light white skin inadvertently develop more hyperpigmentation than his darker skinned French counterpart? The new classification introduced here is based on the racial and genetic origins of patients. It suggests that racial genetic predisposition is the determining factor in human response to skin injury, including skin treatments. This classification takes into account both skin and features, rather than skin alone. It offers a new approach in evaluating patients scheduled for skin peels or laser resurfacing, in the hope of helping physicians to better predict reactions, select the appropriate type and intensity of the skin treatment and, ultimately, better control the outcome. Six categories (sub-races) are described: Nordics, Europeans, Mediterraneans, Indo-Pakistanis, Africans, and Asians. The reaction of each sub-race to peels, laser resurfacing, or dermabrasion is analyzed. The risks associated with each group are noted. This new classification provides physicians with a practical way to evaluate patients prior to treatment, with a view to determining each patient's suitability, postoperative reaction, the likelihood of complications, and likely result.

  9. The use of a prosthetic inlay resurfacing as a salvage procedure for a failed cartilage repair.

    Science.gov (United States)

    Dhollander, Aad Alfons Maria; Almqvist, Karl Fredrik; Moens, Kris; Vandekerckhove, Pieter-Jan; Verdonk, René; Verdonk, Peter; Victor, Jan

    2015-08-01

    This study was designed to describe the clinical and radiographical outcome of the HemiCAP(®) resurfacing system as a salvage treatment for a failed index cartilage procedure. Fourteen patients were treated consecutively and clinically prospectively followed for a mean period of 26.1 ± 12.8 months. All patients were previously treated for their cartilage lesion. Radiographical data were analysed based on the Kellgren and Lawrence system. The patients involved in this study demonstrated a gradual clinical improvement in time. However, radiographically significant osteoarthritic changes were observed during the follow-up period. The position of the HemiCAP(®) resurfacing system was adequate in all cases, and no signs of loosening were observed during the follow-up period. The HemiCAP(®) resurfacing system is feasible as a salvage treatment for a failed index cartilage procedure and resulted in a gradual clinical improvement. However, the favourable clinical outcome was not confirmed by the radiographical findings. IV.

  10. Progressive glenoid bone loss caused by erosion in humeral head resurfacing.

    Science.gov (United States)

    Werner, B S; Stehle, J; Abdelkawi, A; Plumhoff, P; Hudek, R; Gohlke, F

    2017-12-01

    Cementless surface replacement of the shoulder represents an alternative to conventional stemmed anatomic prostheses. Glenoid erosion is a well-known complication in hemiarthroplasty. However, there is limited data concerning radiographic evaluation and prognostic factors for this phenomenon. The aim of our study was to determine the development of glenoid erosion following shoulder resurfacing using a new measurement technique and detect potential prognostic factors. We performed a retrospective analysis on 38 shoulders undergoing humeral head resurfacing with a mean follow-up of 65.4 ± 43 months. Clinical and radiographic evaluation followed a standardized protocol including pre- and postoperative Constant score, active range of motion, and X‑rays in true anteroposterior view. Three independent observers performed measurements of glenoid erosion. We found good interobserver reliability for glenoid erosion measurements (intraclass correlation coefficient [ICC] 0.74-0.78). Progressive glenoid erosion was present in all cases, averaging 5.5 ± 3.9 mm at more than 5 years' follow-up. Male patients demonstrated increased glenoid bone loss within the first 5 years (p erosion was 37%. Glenoid erosion can be routinely expected in patients undergoing humeral head resurfacing. Painful glenoid erosion leads to deterioration in functional outcome and necessitates revision surgery in a high percentage of cases.

  11. Burnishing Techniques Strengthen Hip Implants

    Science.gov (United States)

    2010-01-01

    In the late 1990s, Lambda Research Inc., of Cincinnati, Ohio, received Small Business Innovation Research (SBIR) awards from Glenn Research Center to demonstrate low plasticity burnishing (LPB) on metal engine components. By producing a thermally stable deep layer of compressive residual stress, LPB significantly strengthened turbine alloys. After Lambda patented the process, the Federal Aviation Administration accepted LPB for repair and alteration of commercial aircraft components, the U.S. Department of Energy found LPB suitable for treating nuclear waste containers at Yucca Mountain. Data from the U.S. Food and Drug Administration confirmed LPB to completely eliminate the occurrence of fretting fatigue failures in modular hip implants.

  12. Metal-on-metal bearings a clinical practicum

    CERN Document Server

    Jones, Lynne C; Greenwald, A Seth

    2014-01-01

    This book addresses the background and significance of factors potentially influencing clinical and biological outcomes of metal-on-metal hip implants. Includes discussion of reported complications including pseudotumors and other lymphocytic-based responses.

  13. Viscous relaxation as a prerequisite for tectonic resurfacing on Ganymede: Insights from numerical models of lithospheric extension

    Science.gov (United States)

    Bland, Michael T.; McKinnon, William B.

    2018-01-01

    Ganymede’s bright terrain formed during a near-global resurfacing event (or events) that produced both heavily tectonized and relatively smooth terrains. The mechanism(s) by which resurfacing occurred on Ganymede (e.g., cryovolcanic or tectonic), and the relationship between the older, dark and the younger, bright terrain are fundamental to understanding the geological evolution of the satellite. Using a two-dimensional numerical model of lithospheric extension that has previously been used to successfully simulate surface deformation consistent with grooved terrain morphologies, we investigate whether large-amplitude preexisting topography can be resurfaced (erased) by extension (i.e., tectonic resurfacing). Using synthetically produced initial topography, we show that when the total relief of the initial topography is larger than 25–50 m, periodic groove-like structures fail to form. Instead, extension is localized in a few individual, isolated troughs. These results pose a challenge to the tectonic resurfacing hypothesis. We further investigate the effects of preexisting topography by performing suites of simulations initialized with topography derived from digital terrain models of Ganymede’s surface. These include dark terrain, fresh (relatively deep) impact craters, smooth bright terrain, and a viscously relaxed impact crater. The simulations using dark terrain and fresh impact craters are consistent with our simulations using synthetic topography: periodic groove-like deformation fails to form. In contrast, when simulations were initialized with bright smooth terrain topography, groove-like deformation results from a wide variety of heat flow and surface temperature conditions. Similarly, when a viscously relaxed impact crater was used, groove-like structures were able to form during extension. These results suggest that tectonic resurfacing may require that the amplitude of the initial topography be reduced before extension begins. We emphasize that

  14. Developmental dysplasia of the hip

    Science.gov (United States)

    ... dislocation of the hip joint; Developmental hip dysplasia; DDH; Congenital dysplasia of the hip; Congenital dislocation of ... during pregnancy can increase a baby's risk of DDH. Other risk factors include: Being the first child ...

  15. Hip fracture surgery

    Science.gov (United States)

    ... allows your surgeon to use an x-ray machine to see how well the parts of your hip bone line up. The surgeon ... allows your surgeon to use an x-ray machine to see how well the parts of your hip bone line up. The surgeon ...

  16. TREATMENT OF HIP DYSPLASIA

    Directory of Open Access Journals (Sweden)

    Iulian ICLEANU

    2015-11-01

    Full Text Available In this thesis, our purpose is to show that using physiotherapy on patients with hip dysplasia from the very beginning, in the first months of life, helps treating them faster. Common literature proposes to use physiotherapy on patients with hip dysplasia either after their recovery or in the terminal phase of recovery, claiming that any earlier intervention will prolong the hip recovery. The effects of hip dysplasia reflect over the whole musculoskeletal system, while it hinders the knees (genu valgum, the ankles (ankle valgus, calcaneal valgus and the spine (scoliosis especially at the lumbar level. The most spectacular are at the hip level, that is why we made an analytical evaluation only for this joint. To show the importance of physiotherapy for children with hip dysplasia we started from the hypothesis: untimely treatment for children with hip dysplasia has improved results in functional recovery and in obtaining a better stability, without the necessity of orthopedics or surgical interventions. The research methods used in this study are: the observation method, the bibliographic study method, the experimental method, the graphics method and the statistical mathematical method to process the data and to represent the results graphically. In the end, the results obtained are significantly different from the initial evaluations and we came to the conclusion that starting an untimely analytical kinetic treatment and globally personalizing it to every patient improves stability and biomechanical parameters for the hip.

  17. High mid-term revision rate after treatment of large, full-thickness cartilage lesions and OA in the patellofemoral joint using a large inlay resurfacing prosthesis

    DEFF Research Database (Denmark)

    Laursen, Jens Ole

    2017-01-01

    pain but high mid-term revision rate after patellofemoral inlay resurfacing using the HemiCAP-Wave® implant. Patellofemoral resurfacing implantation treatment with a large inlay prosthesis can offer temporary treatment for large isolated patellofemoral cartilage lesions or OA in younger patients...

  18. Formed HIP Can Processing

    Energy Technology Data Exchange (ETDEWEB)

    Clarke, Kester Diederik [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-07-27

    The intent of this report is to document a procedure used at LANL for HIP bonding aluminum cladding to U-10Mo fuel foils using a formed HIP can for the Domestic Reactor Conversion program in the NNSA Office of Material, Management and Minimization, and provide some details that may not have been published elsewhere. The HIP process is based on the procedures that have been used to develop the formed HIP can process, including the baseline process developed at Idaho National Laboratory (INL). The HIP bonding cladding process development is summarized in the listed references. Further iterations with Babcock & Wilcox (B&W) to refine the process to meet production and facility requirements is expected.

  19. Trends in Primary and Revision Hip Arthroplasty Among Orthopedic Surgeons Who Take the American Board of Orthopedics Part II Examination.

    Science.gov (United States)

    Eslam Pour, Aidin; Bradbury, Thomas L; Horst, Patrick K; Harrast, John J; Erens, Greg A; Roberson, James R

    2016-07-01

    A certified list of all operative cases performed within a 6-month period is a required prerequisite for surgeons taking the American Board of Orthopaedic Surgery Part II oral examination. Using the American Board of Orthopaedic Surgery secure Internet database database containing these cases, this study (1) assessed changing trends for primary and revision total hip arthroplasty (THA) and (2) compared practices and early postoperative complications between 2 groups of examinees, those with and without adult reconstruction fellowship training. Secure Internet database was searched for all 2003-2013 procedures with a Current Procedural Terminology code for THA, hip resurfacing, hemiarthroplasty, revision hip arthroplasty, conversion to THA, or removal of hip implant (Girdlestone, static, or dynamic spacer). Adult reconstruction fellowship-trained surgeons performed 60% of the more than 33,000 surgeries identified (average 28.1) and nonfellowship-trained surgeons performed 40% (average 5.2) (P revision surgeries for infection (71% vs 29%)(P revision surgeries (29% vs 35.5%) (P revision hip arthroplasties are often performed by surgeons without adult reconstruction fellowship training. Complications are less frequently reported by surgeons with larger volumes of joint replacement surgery who perform either primary or more complex cases. Primary hip arthroplasty is increasingly performed by surgeons early in practice who have completed an adult reconstructive fellowship after residency training. This trend is even more pronounced for more complex cases such as revision or management of infection. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Transmastoid Approach for Resurfacing the Superior Semicircular Canal Dehiscence with a Dumpling Structure

    Directory of Open Access Journals (Sweden)

    Xiao-Bo Ma

    2015-01-01

    Full Text Available Background: Superior semicircular canal dehiscence (SSCD is gradually recognized by otologists in recent years. The patients with SSCD have a syndrome comprising a series of vestibular symptoms and hearing function disorders which can be cured by the operation. In this study, we evaluated the characteristics of patients with SSCD and determined the effectiveness of treating this syndrome by resurfacing the canal via the transmastoid approach using a dumpling structure. Methods: Patients with SSCD, confirmed by high-resolution computed tomography and hospitalized at Beijing Tongren Hospital between November 2009 and October 2012, were included in the study. All of the patients underwent the unilateral transmastoid approach for resurfacing the canal, and received regular follow-up after surgery. Data from preoperative medical records and postoperative follow-up were comparatively analyzed to evaluate the effect of surgery. Results: In total, 10 patients and 13 ears (three left ears, four right ears, three bilateral ears were evaluated in the study, which included 7 men and 3 women. Different symptoms and distinctive manifestations of vestibular evoked myogenic potential were found in these patients. After surgery, 4 patients had complete resolution, 5 had partial resolution, and 1 patient, with bilateral SSCD, had aggravation. None of the patients suffered from serious complications such as sensorineural hearing loss, facial paralysis, cerebrospinal fluid leakage, or intracranial hypertension. Conclusions: In patients with unilateral SSCD, resurfacing the canal via the transmastoid approach using a dumpling structure is an effective and safe technique. However, more consideration is needed for patients with bilateral SSCD.

  1. Resurfacing of pitted facial scars with a pulsed Er:YAG laser.

    Science.gov (United States)

    Kye, Y C

    1997-10-01

    Laser resurfacing has beneficial effects for the treatment of several skin conditions. Recently, the pulsed Er:YAG laser has been shown to be a highly effective treatment for several kinds of pitted facial scars. The purpose of this study was to assess the efficacy and safety of pulsed Er:YAG laser skin resurfacing for pitted facial scars. Four patients with small pox scars, five patients with chicken pox scars, and 21 patients with acne scars were included in this study. All patients were skin type III and IV. All patients were instructed to use tretinoin cream 0.05% nightly for 2-4 weeks prior to the laser treatment. The pulsed Er:YAG laser with 2-mm handpiece at the setting of 500 mJ/pulse, 3.5-4.5 W was used. Two weeks after laser treatment, topical application of hydroquinone 4%, tretinoin 0.05%, and hydrocortisone 1% cream was recommended for 2-4 weeks. Facial photographs were obtained at baseline and 2-week intervals postoperatively with a 35-mm single lense reflex camera equipped with a lense mounted ring flash. The results of treatment were evaluated for the changes of skin texture and color at 2 weeks, 1 month, and 3 months. Three patients with acne scars agreed to skin biopsy. Three months after laser treatment, all patients with small pox and chicken pox scars were improved about 55%, and patients with acne scars were improved about 40% on average. Pulsed Er:YAG laser skin resurfacing is an effective and safe treatment for pitted facial scars.

  2. Economically and environmentally informed policy for road resurfacing: tradeoffs between costs and greenhouse gas emissions

    Science.gov (United States)

    Reger, Darren; Madanat, Samer; Horvath, Arpad

    2014-10-01

    As road conditions worsen, users experience an increase in fuel consumption and vehicle wear and tear. This increases the costs incurred by the drivers, and also increases the amount of greenhouse gases (GHGs) that vehicles emit. Pavement condition can be improved through rehabilitation activities (resurfacing) to reduce the effects on users, but these activities also have significant cost and GHG emission impacts. The objective of pavement management is to minimize total societal (user and agency) costs. However, the environmental impacts associated with the cost-minimizing policy are not currently accounted for. We show that there exists a range of potentially optimal decisions, known as the Pareto frontier, in which it is not possible to decrease total emissions without increasing total costs and vice versa. This research explores these tradeoffs for a system of pavement segments. For a case study, a network was created from a subset of California’s highways using available traffic data. It was shown that the current resurfacing strategy used by the state’s transportation agency, Caltrans, does not fall on the Pareto frontier, meaning that significant savings in both total costs and total emissions can be achieved by switching to one of the optimal policies. The methods presented in this paper also allow the decision maker to evaluate the impact of other policies, such as reduced vehicle kilometers traveled or better construction standards.

  3. Implications of the Utopia Gravity Anomaly for the Resurfacing of the Northern Plains of Mars

    Science.gov (United States)

    Banerdt, W. B.

    2004-01-01

    Whereas the surface units of the northern plain of Mars generally exhibit ages ranging from late Hesperian to Amazonian, interpretation of precise topographic measurements indicate that the age of the underlying "basement" is early Noachian, or almost as old as the southern highlands. This suggests that widespread but relatively superficial resurfacing has occurred throughout the northern plains since the end of early heavy bombardment. In this abstract I examine some of the possible implications of the subsurface structure inferred for the Utopia basin from gravity data on the nature of this resurfacing. The large, shallow, circular depression in Utopia Planitia has been identified as a huge impact basin, based on both geological evidence and detailed analysis of MOLA topography. Its diameter (approx. 3000 km) is equivalent to that of the Hellas basin, as is its inferred age (early Noachian). However, whereas Hellas is extremely deep with rough terrain and large slopes, the Utopia basin is a smooth, shallow, almost imperceptible bowl. Conversely, Utopia displays one of the largest (non-Tharsis-related) positive geoid anomalies on Mars, in contrast to a much more subdued negative anomaly over Hellas.

  4. Polydeoxyribonucleotide improves wound healing of fractional laser resurfacing in rat model.

    Science.gov (United States)

    Yu, Mi; Lee, Jun Young

    2017-02-01

    Polydeoxyribonucleotide (PDRN) is an active compound that can promote wound healing. PDRN stimulates wound healing by enhancing angiogenesis and increasing fibroblast growth rates. Laser skin resurfacing is a popular cosmetic procedure for skin rejuvenation. Despite excellent improvement of photo-damaged skin and acne scarring, it is accompanied with drawbacks, such as prolonged erythema and crusting. This study was designed to assess the effect of PDRN on wounds induced by fractional laser resurfacing. Twelve male rats aged 8 weeks were randomly assigned to the PDRN treatment group and the control group. Wounds were induced using a fractional ablative CO 2 laser. The treatment group received daily injections of PDRN and the control group received injections of the vehicle. Wound healing assessed by clinical features and histopathologic findings. The process of wound healing was faster in the treatment group than in the control group. In the histopathological examination, the granulation tissue thickness score of the treatment group was significantly higher than that of the control group. Results of immunohistochemical staining showed a marked increase of VEGF-positive cells and PECAM-1/CD31-positive microvessels in the treatment group. PDRN may be a beneficial option to promote wound healing after laser treatment.

  5. Finite element analysis of 2-Station hip himulator

    Science.gov (United States)

    Fazli, M. I. M.; Yahya, A.; Shahrom, A.; Nawawi, S. W.; Zainudin, M. R.; Nazarudin, M. S.

    2017-10-01

    This paper presented the analysis of materials and design architecture of 2-station hip simulator. Hip simulator is a machine used to conduct the joint and wear test of hip prosthetic. In earlier work, the hip simulator was modified and some improvement were made by using SolidWorks software. The simulator consists of 3DOF which controlled by separate stepper motor and a static load that set up by manual method in each station. In this work, finite element analysis (FEA) of hip simulator was implemented to analyse the structure of the design and selected materials used for simulator component. The analysis is completed based on two categories which are safety factor and stress tests. Both design drawing and FEA was done using SolidWorks software. The study of the two categories is performed by applying the peak load up to 4000N on the main frame that is embedded with metal-on-metal hip prosthesis. From FEA, the value of safety factor and degree of stress formation are successfully obtained. All the components exceed the value of 2 for safety factor analysis while the degree of stress formation shows higher value compare to the yield strength of the material. With this results, it provides information regarding part of simulator which are susceptible to destruct. Besides, the results could be used for design improvement and certify the stability of the hip simulator in real application.

  6. Alumina-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty

    OpenAIRE

    Jung, Yup Lee; Kim, Shin-Yoon

    2010-01-01

    The long-term durability of polyethylene lining total hip arthroplasty (THA) mainly depends on periprosthetic osteolysis due to wear particles, especially in young active patients. In hip simulator study, reports revealed significant wear reduction of the alumina ceramic-on-polyethylene articulation of THA compared with metal-on-polyethylene bearing surfaces. However, medium to long-term clinical studies of THA using the alumina ceramic-on-polyethylene are few and the reported wear rate of th...

  7. Transient osteoporosis of the hip

    International Nuclear Information System (INIS)

    McWalter, Patricia; Hassan Ahmed

    2007-01-01

    Transient osteoporosis of the hip is an uncommon cause of hip pain, mostly affecting healthy middle-aged men and also women in the third trimester of pregnancy. We present a case of transient osteoporosis of the hip in a 33-year-old non-pregnant female patient. This case highlights the importance of considering a diagnosis of transient osteoporosis of the hip in patients who present with hip pain. (author)

  8. Resultados de artroplastia total de joelho com e sem implante de recapeamento (resurfacing patelar Results of total knee replacement with/without resurfacing of the patella

    Directory of Open Access Journals (Sweden)

    Abdul Khan

    2012-01-01

    Full Text Available OBJETIVO: Estudar a diferença de dor, estalido e crepitação patelofemoral no pós-operatório em pacientes com ou sem recapeamento patelar após 5 anos, os quais tinham dor patelofemoral antes da cirurgia. Estudar a incidência de dor, estalido e crepitação patelofemoral depois de pateloplastia em ambos os grupos. MÉTODOS: Revisão retrospectiva de 765 pacientes submetidos a artroplastia total do joelho (ATJ com ou sem recapeamento patelar. Os pacientes foram perguntados sobre dor pré e pós-operatória, 5 anos depois da cirurgia. Foram examinados por enfermeiro especializado 5 anos, após a cirurgia para verificar estalidos ou crepitação patelofemoral (PF. RESULTADOS: 688 pacientes (89,9% tinham dor PF pré-operatória. De 688 pacientes, 449 tinham recapeamento patelar (R e 239 não tinham (NR. Trinta e seis pacientes do grupo NR tinham pateloplastia. A incidência de dor PF pós-operatória foi 13,3% no grupo R e 13,6% no grupo NR. A incidência de estalido PF pós-operatório no grupo R foi 10,4% e apenas 1,3% no grupo NR (estatisticamente significante, p OBJECTIVE: To study the difference of post-op patellofemoral pain, clunk and crepitus in patients with/without resurfacing at 5 years who had pre-op patellofemoral pain. To study the incidence of post-operative patellofemoral pain, clunk and crepitus following patelloplasty in both the groups. METHODS: Retrospective review of 765 patients who had total knee replacement with/without resurfacing.Patients were asked about both pre-operative pain and also post-operative pain 5 years after the operation. Patients were examined by a specialist nurse at 5 years post-operatively to check for any patellofemoral clunk/crepitus. RESULTS: 688 patients (89.9% had preoperative PF pain. Of 688 patients, 449 had patellar resurfacing and 239 had not (NR. Thirty-six patients from the NR group had patelloplasty. The incidence of postoperative PF pain was 13.3% in the R group and 13.6% in the NR group

  9. Hip Labral Tear

    Science.gov (United States)

    ... are often associated with sports participation. If your sport puts a lot of strain on your hips, condition the surrounding muscles with strength and flexibility exercises. Try to avoid loading your ...

  10. Imaging of hip arthroplasty

    International Nuclear Information System (INIS)

    Breitenseher, M.J.; Mayerhoefer, M.; Gottsauner-Wolf, F.; Krestan, C.; Imhof, H.; Toma, C.D.

    2002-01-01

    Hip arthroplasty has become a common and still increasing procedure for the treatment of osteoarthritis, advanced head necrosis, post-inflammatory arthritis or rheumatoid arthritis.Radiography is the most important imaging modality for monitoring the normal, asymptomatic hip arthroplasty. Radiographs are obtained at the end of a surgical treatment, to exclude complications like fracture or component misplacement. In the follow-up radiographs are used for the diagnosis of loosening and infection of the hip arthroplasty as well as soft tissue ossification. Together with the history and clinical information, the analysis of morphological findings allows to find the grade of loosening. MRI has been advocated in the diagnosis of infection, in particular in the localisation of soft tissue involvement.Imaging, especially by radiographs, is used for the evaluation of the normal and complicated follow-up of hip arthroplasty. (orig.) [de

  11. Survey and Cleaning of Metal Contamination in Graphite Plasma-Facing Tiles in DIII-D

    Science.gov (United States)

    Chrobak, C. P.; Chamberlain, F.; Lee, R. L.; Holtrop, K. L.; Taylor, P. L.; Jackson, G. L.; Wall, D.; Buchenauer, D. A.; Mills, B. E.

    2012-10-01

    During the DIII-D FY11 and FY12 campaigns, relatively high levels of high Z metallic core plasma impurities impeded high performance plasma operation. Observations made during a vessel entry revealed potential sources of the increased metals, including: copper and Inconel splatter from a probe head damaged by runaway electrons, partial melting of a neutral beam molybdenum shield plate, and exposed metals on the Fast Wave antenna Faraday shields. Portable beta-backscattering and x-ray fluorescence diagnostics were used to map the areal density of metals deposited on the graphite plasma-facing tiles around the vessel. Tile surfaces with deposits exceeding 7x10^16 metal atoms/cm^2 were sanded in place or grit blasted outside of the vessel to remove impurities. The distribution of metals before and after resurfacing and the effectiveness of the tile resurfacing techniques on subsequent plasmas will be presented.

  12. Effects of metal-inlay thickness in polyethylene cups with metal-on-metal bearings.

    NARCIS (Netherlands)

    Verdonschot, N.J.J.; Vena, P.; Stolk, J.; Huiskes, R.

    2002-01-01

    A way to prevent polyethylene wear in total hip replacements is to use metal-on-metal bearings. The cup design of these bearings may be a metal inlay in a polyethylene cup. However, these metal inlays are relatively thin and may deform on loading. The purpose of the current study was to determine

  13. Athletic Hip Injuries.

    Science.gov (United States)

    Lynch, T Sean; Bedi, Asheesh; Larson, Christopher M

    2017-04-01

    Historically, athletic hip injuries have garnered little attention; however, these injuries account for approximately 6% of all sports injuries and their prevalence is increasing. At times, the diagnosis and management of hip injuries can be challenging and elusive for the team physician. Hip injuries are seen in high-level athletes who participate in cutting and pivoting sports that require rapid acceleration and deceleration. Described previously as the "sports hip triad," these injuries consist of adductor strains, osteitis pubis, athletic pubalgia, or core muscle injury, often with underlying range-of-motion limitations secondary to femoroacetabular impingement. These disorders can happen in isolation but frequently occur in combination. To add to the diagnostic challenge, numerous intra-articular disorders and extra-articular soft-tissue restraints about the hip can serve as pain generators, in addition to referred pain from the lumbar spine, bowel, bladder, and reproductive organs. Athletic hip conditions can be debilitating and often require a timely diagnosis to provide appropriate intervention.

  14. Comparison of high-energy pulsed carbon dioxide laser resurfacing and dermabrasion in the revision of surgical scars.

    Science.gov (United States)

    Nehal, K S; Levine, V J; Ross, B; Ashinoff, R

    1998-06-01

    Both dermabrasion and high-energy pulsed carbon dioxide (CO2) laser resurfacing can improve the appearance of surgical scars. Although the results of these two procedures have been compared using historical data, a prospective evaluation has never been performed in humans. To prospectively compare the clinical effects of dermabrasion and high-energy pulsed CO2 laser resurfacing in the revision of surgical scars. Facial surgical scars in four patients were prospectively revised using a split scar model. One half of the scar was dermabraded and the other half was resurfaced with the high-energy pulsed CO2 laser. Comparisons of the two treatment modalities were performed through clinical assessment, photographic evaluation, and textural analysis of the scars. The high-energy pulsed CO2 laser-resurfaced halves of the scar were bloodless with less postoperative crusting in comparison with the dermabraded halves. Reepithelialization time and degree and duration of postoperative erythema were similar for both treatment halves. Photographic evaluation and textural analysis showed comparable improvement in the clinical appearance and surface texture of the scars with both treatment modalities. Both the high-energy pulsed CO2 laser and dermabrasion can achieve comparable clinical improvement in the revision of surgical scars. The high-energy pulsed CO2 laser offers the advantage of a bloodless field and a more precise method of tissue ablation. Postoperative erythema, however, is an expected finding with both treatment modalities.

  15. Implant Optimisation for Primary Hip Replacement in Patients over 60 Years with Osteoarthritis: A Cohort Study of Clinical Outcomes and Implant Costs Using Data from England and Wales.

    Directory of Open Access Journals (Sweden)

    Simon S Jameson

    Full Text Available Hip replacement is one of the most commonly performed surgical procedures worldwide; hundreds of implant configurations provide options for femoral head size, joint surface material and fixation method with dramatically varying costs. Robust comparative evidence to inform the choice of implant is needed. This retrospective cohort study uses linked national databases from England and Wales to determine the optimal type of replacement for patients over 60 years undergoing hip replacement for osteoarthritis.Implants included were the commonest brand from each of the four types of replacement (cemented, cementless, hybrid and resurfacing; the reference prosthesis was the cemented hip procedure. Patient reported outcome scores (PROMs, costs and risk of repeat (revision surgery were examined. Multivariable analyses included analysis of covariance to assess improvement in PROMs (Oxford hip score, OHS, and EQ5D index (9159 linked episodes and competing risks modelling of implant survival (79,775 procedures. Cost of implants and ancillary equipment were obtained from National Health Service procurement data.EQ5D score improvements (at 6 months were similar for all hip replacement types. In females, revision risk was significantly higher in cementless hip prostheses (hazard ratio, HR = 2.22, p<0.001, when compared to the reference hip. Although improvement in OHS was statistically higher (22.1 versus 20.5, p<0.001 for cementless implants, this small difference is unlikely to be clinically important. In males, revision risk was significantly higher in cementless (HR = 1.95, p = 0.003 and resurfacing implants, HR = 3.46, p<0.001, with no differences in OHS. Material costs were lowest with the reference implant (cemented, range £1103 to £1524 and highest with cementless implants (£1928 to £4285. Limitations include the design of the study, which is intrinsically vulnerable to omitted variables, a paucity of long-term implant survival data (reflecting the

  16. Patellar resurfacing versus nonresurfacing in total knee arthroplasty for osteoarthritis: experience at a tertiary care institution in Pakistan

    Directory of Open Access Journals (Sweden)

    Lakdawala RH

    2012-02-01

    Full Text Available Akil Fazal1, Riaz H Lakdawala21Clinical Fellow, NYU Hospital for Joint Disease, New York, US; 2Associate Professor and Chief, Section of Orthopedics, Department of Surgery, The Aga Khan University Hospital, Karachi, PakistanObjective: To determine the effect of patellar resurfacing in patients offered total knee arthroplasty for osteoarthritis.Design: Randomized control study.Place and duration of study: The Aga Khan University Hospital, Karachi, Pakistan from January 3, 2005 to January 9, 2010.Patients and methods: Patients undergoing primary total knee arthroplasty for osteoarthritis were assigned to either the patellar resurfacing or nonresurfacing arm using systematic sampling. This consisted of patients undergoing unilateral and bilateral knee arthroplasty. Preoperatively, Knee Society Knee and Function Scores were calculated. After a minimum of 3 years postoperatively Knee Society Knee and Function Scores as well as the Clinical Anterior Knee Pain Rating were calculated and analysis done to check for differences.Results: Seventy-five patients were recruited in each arm; 135 patients had bilateral and 15 had unilateral knee arthroplasty. The mean preoperative knee score was 40.4 for the resurfacing group and 40.60 for the nonresurfacing group (P = 0.45. This improved postoperatively to 93.67 and 94.23 respectively, with no difference between the two groups (P = 0.67. The mean preoperative function score was 45.50 for resurfaced patellae and 45.83 for nonresurfaced. This improved to 89.67 and 90.50, respectively, again with no difference (P = 0.51. Postoperative Clinical Anterior Knee Pain Rating was a mean of 0.1 for resurfaced and 0.13 for nonresurfaced patellas, with no difference on analysis (P = 0.06. However, patients who had bilateral knee arthroplasty had a slightly higher Clinical Anterior Knee Pain Rating than those who had single knee surgery (P = 0.046 irrespective of whether the patellar was resurfaced or not.Conclusion: In

  17. Evaluación de metales redox-sensitivos como proxies de paleoxigenación en un ambiente marino hipóxico del norte de Chile Redox-sensitive metals evaluation as proxis of paleoxygenation in a hypoxic marine environment of northern Chile

    Directory of Open Access Journals (Sweden)

    JORGE VALDÉS

    2004-03-01

    Full Text Available Se analizó la distribución de molibdeno, cadmio, zinc, vanadio y níquel, todos metales redox-sensitivos, bajo una perspectiva espacial (sedimento superficial y temporal (testigos de sedimento, con el propósito de determinar su potencial como indicadores de paleoxigenación en la bahía Mejillones del Sur, un ambiente hipóxico del norte de Chile. El aporte litogénico (de acuerdo a aluminio fue descartado. Además, el flujo biogénico no es el único factor que controla la preservación de metales en esta bahía. La variación espacial en la concentración de metales fue investigada en relación con la oxigenación de las aguas de fondo. Los resultados mostraron que solo el Ni y el Cd presentan una correlación significativa con el oxígeno disuelto, aumentando sus concentraciones hacia el sector más profundo de la bahía, en donde prevalecen condiciones de mínimo oxígeno, con valores cercanos a 0,02 mL L-1. La variación temporal en la concentración de metales redox-sensitivos, registrada en tres testigos de sedimento que cubren los pasados 2.000 años, mostró que, en general, la oxigenación de fondo de la bahía ha cambiado desde un ambiente más oxigenado en el pasado, hacia un ambiente menos oxigenado en el presente. Se propone que el flujo biogénico a través de una oxiclina bien desarrollada, asociado a una condición anóxica de la interfase agua-sedimento son los principales factores que permiten explicar la concentración de metales que se preserva en los sedimentos marinos de Mejillones durante condiciones no-El Niño/La Niña. Cuando El Niño está presente en la bahía, se profundiza la oxiclina, aumentando el nivel de oxigenación de las aguas subsuperficiales al interior de la bahía, lo que provoca que la precipitación de metales hacia los sedimentos disminuya, favoreciendo, a su vez, la liberación de metales desde la interfase agua-sedimento. Basado en esto, se plantea que las diferencias en la concentración de

  18. Complications in Hip Arthroscopy

    Science.gov (United States)

    Nakano, Naoki; Khanduja, Vikas

    2016-01-01

    Summary Background Recent developments in hip arthroscopic techniques and technology have made it possible in many cases to avoid open surgical dislocation for treating a variety of pathology in the hip. Although early reports suggest favourable results’ using hip arthroscopy and it has been shown to be a relatively safe procedure, complications do exist and can sometimes lead to significant morbidity. Methods This is a review article. The aim of this manuscript is to present the most frequent and/or serious complications that could occur at or following hip arthroscopy and some guidelines to avoid these complications. Conclusion Most complications of hip arthroscopy are minor or transient but serious complications can occur as well. A lot of complication e.g. acetabular labral puncture go unreported. Appropriate education and training, precise and meticulous surgical technique with correct instrumentation, the right indication in the right patient and adherence to advice from mentors and experienced colleagues are all essential factors for a successful outcome. Level of evidence: V. PMID:28066747

  19. Skin resurfacing in a circumferential full thickness burn to the penis: lessons learnt.

    Science.gov (United States)

    Jabir, Shehab; Frew, Quentin; Thompson, Richard; Dziewulski, Peter

    2013-08-13

    A circumferential full-thickness burn to the penis is a rarely encountered injury. However, when it does occur, it proves a management challenge to the plastic and burns surgeon in terms of reconstruction. This is due to the need of not only regaining adequate function of the organ, but also because of the need for a pleasing aesthetic outcome. Split-skin grafts have been utilised successfully to resurface full thickness burns of the penis and have given good results. Yet the success of split-skin grafts, especially those applied to an anatomically challenging region of the body such as the penis, depends on a number of carefully thought-out steps. We discuss the case of a circumferential full-thickness burn to the penis which was treated with split-skin grafting and highlight important pitfalls that the plastic and burns surgeon need to be aware of to ensure a successful outcome.

  20. 100-μsec pulsed CO2 laser resurfacing of lower eyelids: erythema and rhytides reduction

    Science.gov (United States)

    Bell, Thomas; Harris, David M.; Schachter, Daniel; Burkart, John

    1997-05-01

    Lower eyelid skin is very thin with a low density of adnexal structures. Attempts to remove rhytides and improve surface appearance with chemical peels and dermabrasion have been disappointing. Laser resurfacing offers a new modality that may improve the outcome. We evaluated a very short duration (100 microsecond(s) ec) pulsed carbon-dioxide laser (Tru-PulseTM) in terms of healing time (duration of erythema) and efficacy (wrinkle reduction). Female patients aged 35 - 75 received laser resurfacing in a variety of cosmetic zones but only data from lower lids are reported here. Dosimetry varied from total fluences of 5 to 20 J/cm2 (9 mm2 spot, 250 - 500 mJ pulse, 1 to 4 passes). Patients followed a strict regime of post-op wound care. Pre-treatment and follow-up photographs were taken in a studio with constant photographic parameters. Projected 35 mm slides were evaluated side-by-side for clinical improvement and presence of erythema. Within the first 4 days post-op all (100%) lower eyelids exhibited erythema and swelling, at 7 days: 71%, 12 days: 60%, 3 weeks: 25%, and one (1) month or longer 7%. In our sample the longest duration of post-op lower lid erythema lasted 5 weeks. Most patients experienced 70 -80% wrinkle reduction with a range of 0 - 100%. Regression analysis was used to evaluate the relationships between percent wrinkle reduction and the treatment, demographic, and evaluation variables. There was a significant trend for wrinkles to improve over the 3 to 9 month evaluation period. Older patients improved slightly more than younger patients. There was no relationship between total energy density and wrinkle reduction.

  1. Sonography for hip joint effusion in adults with hip pain

    NARCIS (Netherlands)

    S.M. Bierma-Zeinstra (Sita); A.M. Bohnen (Arthur); J.A.N. Verhaar (Jan); A. Prins (Ad); J.S. Lameris; A.Z. Ginai (Abida)

    2000-01-01

    textabstractOBJECTIVE: To study the prevalence of ultrasonic hip joint effusion and its relation with clinical, radiological and laboratory (ESR) findings in adults with hip pain. METHODS: Patients (n = 224) aged 50 years or older with hip pain, referred by the general

  2. Sonography for hip joint effusion in adults with hip pain

    NARCIS (Netherlands)

    Bierma-Zeinstra, S. M.; Bohnen, A. M.; Verhaar, J. A.; Prins, A.; Ginai-Karamat, A. Z.; Laméris, J. S.

    2000-01-01

    To study the prevalence of ultrasonic hip joint effusion and its relation with clinical, radiological and laboratory (ESR) findings in adults with hip pain. Patients (n = 224) aged 50 years or older with hip pain, referred by the general practitioner for radiological investigation, underwent a

  3. HIP DYSPLASIA IN TORNJAK

    Directory of Open Access Journals (Sweden)

    Hrvoje Milošević

    2012-07-01

    Full Text Available Canine hip dysplasia (CHD is a hereditary developmental anomaly, most frequent in large dog breeds. Clinical confirmation of the disorder is based on hip X-ray imaging. Twenty Tornjak dogs aged between 9-36 months, and weighted from 35-42 kg were examined for CHD. Scoring was performed according to six clearly defined radiographic parameters by Flueckiger method (5. Dysplastic changes of various severity were observed in 11 dogs, while in 9 dogs changes were absent. The study describes 4 CHD cases of varying degrees of severity. The results indicate the presence of CHD in Bosnian Tornjak. Determining the incidence of dysplasia in this autochthonous breed requires a more detailed study, which will enable determination of the prevalence of dysplasia and analysis of the relationship to other dog breeds. Key words: canine hip dysplasia, Bosnian Tornjak

  4. Hip joint pathology

    DEFF Research Database (Denmark)

    Tijssen, M; van Cingel, R E H; de Visser, E

    2017-01-01

    The purpose of this retrospective cohort study was to (a) describe the clinical presentation of femoroacetabular impingement (FAI) and hip labral pathology; (b) describe the accuracy of patient history and physical tests for FAI and labral pathology as confirmed by hip arthroscopy. Patients (18......-65 years) were included if they were referred to a physical therapist to gather pre-operative data and were then diagnosed during arthroscopy. Results of pre-operative patient history and physical tests were collected and compared to arthroscopy. Data of 77 active patients (mean age: 37 years) were...

  5. Hip Arthroscopy in The Athlete

    OpenAIRE

    Byrd, J.W. Thomas

    2007-01-01

    Sports related injuries to the hip have received relatively little attention, in the part because the clinical assessment, imaging studies, and surgical techniques are less sophisticated. The evolution of hip arthroscopy has offered a less invasive technique that allows for recognition and treatment of hip pathologies that previously went unrecognized. The success of hip arthoscopy is dependent on proper patient selection based on the patient's history and diagnosis. The purpose of this clini...

  6. The digital global geologic map of Mars: chronostratigraphic ages, topographic and crater morphologic characteristics, and updated resurfacing history

    Science.gov (United States)

    Tanaka, K.L.; Robbins, S.J.; Fortezzo, C.M.; Skinner, J.A.; Hare, T.M.

    2014-01-01

    A new global geologic map of Mars has been completed in a digital, geographic information system (GIS) format using geospatially controlled altimetry and image data sets. The map reconstructs the geologic history of Mars, which includes many new findings collated in the quarter century since the previous, Viking-based global maps were published, as well as other discoveries that were made during the course of the mapping using new data sets. The technical approach enabled consistent and regulated mapping that is appropriate not only for the map's 1:20,000,000 scale but also for its widespread use by diverse audiences. Each geologic unit outcrop includes basic attributes regarding identity, location, area, crater densities, and chronostratigraphic age. In turn, units are grouped by geographic and lithologic types, which provide synoptic global views of material ages and resurfacing character for the Noachian, Hesperian, and Amazonian periods. As a consequence of more precise and better quality topographic and morphologic data and more complete crater-density dating, our statistical comparisons identify significant refinements for how Martian geologic terrains are characterized. Unit groups show trends in mean elevation and slope that relate to geographic occurrence and geologic origin. In comparison with the previous global geologic map series based on Viking data, the new mapping consists of half the number of units due to simpler, more conservative and globally based approaches to discriminating units. In particular, Noachian highland surfaces overall have high percentages of their areas now dated as an epoch older than in the Viking mapping. Minimally eroded (i.e., pristine) impact craters ≥3 km in diameter occur in greater proportion on Hesperian surfaces. This observation contrasts with a deficit of similarly sized craters on heavily cratered and otherwise degraded Noachian terrain as well as on young Amazonian surfaces. We interpret these as reflecting the

  7. Skin resurfacing improved with a new dual wavelength Er:YAG/CO2 laser system: a comparative study.

    Science.gov (United States)

    Trelles, M A; García-Solana, L; Calderhead, R G

    1999-06-01

    The efficacy of a new dual wavelength Er:YAG and CO2 laser system was tested for skin resurfacing results on rabbits' ears and human facial skin. The dual wavelength laser delivers simultaneous pulses of low-energy CO2 and high-energy Er:YAG energies. Theoretically, combining the strengths of both laser types in one console should lead to improved clinical outcome. The use of the laser for skin resurfacing and remodeling has dramatically increased over the past few years. The CO2 laser was the first laser to be used in this field, followed more recently by the E:YAG laser. Both lasers offer unique advantages and disadvantages. The present study consists of an ear chamber experiment, conducted on eight rabbits, to examine vascular network formation, after laser resurfacing with a standard CO2 laser and the Er:YAG/CO2 laser. Resurfacing was also performed on human patients with the Er:YAG/CO2 laser and the results were compared with previously published results of CO2 laser resurfacing. Significant advantages, including an attenuation in the degree of edema and erythema and a shorter reepithelialization time compared to results with conventional CO2 systems, were observed with the Er:YAG/CO2 system. Improved tissue reorganization and good clinical results in nine of the ten patients (six ratings of "very good" and three "good") were observed. The clinical outcome of the remaining patient was rated as "fair." Minimal side effects were reported and observed in only three patients. The learning curve required to maximize the efficiency of the system is steep, however, requiring a thorough understanding of the different laser/tissue interactions associated with the two wavelengths. It is the authors' opinion that the dual wavelength Er:YAG/CO2 laser system offers a particularly efficient and flexible system to perform standard CO2 procedures for skin resurfacing with an improved clinical outcome, as well as other applications with the CO2 or Er:YAG energy delivered

  8. [Progress on classification and application of artificial hip joint materials].

    Science.gov (United States)

    Wu, Xiao; He, Ben-xiang; Tan, Ya-jun

    2016-03-01

    The selection of the prosthetic material determine the success or failure of hip arthroplasty. Currently, the metals, ceramics, polymer composites and carbon materials are the main prosthetic materials of artificial hip joint. They have some progresses in biocompatibility, elastic modulus,mechanical properties, useful life, but they still can't reach the ideal standard of design. In this essay, we mainly review the characteristics and applications of the current artificial hip joint materials through its classification in order to provide a reference for choosing appropriate hip joint materials in clinic and increasing characteristic of materials. We consider the polymer composites has more advantages such as biocompatibility, mechanical properties, corrosion resistance and price, even if it has shortages in abrasion resistance. As the researches of polymer composites are main focus on abrasion resistance, articular surface and strength,and its performances are increased fast, it has a wide prospect in future.

  9. [Are the cobalt hip prosthesis dangerous?].

    Science.gov (United States)

    Mistretta, Virginie; Kurth, William; Charlier, Corinne

    The placement of a hip prosthesis is one of the most common orthopedic surgical procedures. Some implants contain metal and are therefore capable of releasing metal particles like cobalt in patients who wear metal prostheses. Cobalt can be responsible of local toxicity (including metallosis, hypersensitivity reaction, and benign tumor) or systemic toxicity (including cardiomyopathy, polycythemia, hypothyroidism, and neurological disorders). To monitor potential toxicity of metal hip prostheses, an annual monitoring of patients implanted is recommended and includes clinical examination, radiological examination and blood cobalt determination. The cobalt concentration in blood allows to estimate the risk of toxicity and to evaluate the performance of the implant. The currently recommended threshold value is equal to 7 µg of cobalt per liter of blood. Our study, conducted on 251 patients over a period of 4 years, has shown that the cobalt concentration average was 2.51 µg/l in blood, with 51 patients having a cobaltemia higher than the threshold of 7 µg/l. © 2016 médecine/sciences – Inserm.

  10. Ultrasound: Infant Hip

    Science.gov (United States)

    ... the womb (breech position) babies with a family history of DDH Also, DDH occurs more frequently in girls than boys and among first-born infants. Doctors will consider all of these factors when deciding whether a baby's hips should be checked by ultrasound. In addition, a ...

  11. In-situ electrochemical study of interaction of tribology and corrosion in artificial hip prosthesis simulators.

    Science.gov (United States)

    Yan, Yu; Dowson, Duncan; Neville, Anne

    2013-02-01

    The second generation Metal-on-Metal (MoM) hip replacements have been considered as an alternative to commonly used Polyethylene-on-Metal (PoM) joint prostheses due to polyethylene wear debris induced osteolysis. However, the role of corrosion and the biofilm formed under tribological contact are still not fully understood. Enhanced metal ion concentrations have been reported widely from hair, blood and urine samples of patients who received metal hip replacements and in isolated cases when abnormally high levels have caused adverse local tissue reactions. An understanding of the origin of metal ions is really important in order to design alloys for reduced ion release. Reciprocating pin-on-plate wear tester is a standard instrument to assess the interaction of corrosion and wear. However, more realistic hip simulator can provide a better understanding of tribocorrosion process for hip implants. It is very important to instrument the conventional hip simulator to enable electrochemical measurements. In this study, simple reciprocating pin-on-plate wear tests and hip simulator tests were compared. It was found that metal ions originated from two sources: (a) a depassivation of the contacting surfaces due to tribology (rubbing) and (b) corrosion of nano-sized wear particles generated from the contacting surfaces. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. Hip Arthroscopy: A Brief History.

    Science.gov (United States)

    Kandil, Abdurrahman; Safran, Marc R

    2016-07-01

    Hip arthroscopy is a fast-growing and evolving field. Like knee and shoulder arthroscopy, hip arthroscopy began as a diagnostic procedure and then progressed to biopsy and resection of abnormalities. Subsequently, it has evolved to repair of various tissues and treatment of underlying causes. As the understanding of the hip joint and its associated pathophysiology grows, indications will continue to expand for this diagnostic and therapeutic modality. This article outlines the historic developments of hip arthroscopy, including advancements in instrumentation and techniques from the days of the first hip arthroscopies to the present day. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Favorable outcome of a total hip arthroplasty with insufficient bone coverage of the roof reinforcement ring

    Directory of Open Access Journals (Sweden)

    Fernando M. Judas

    2015-01-01

    Conclusion: This result can be supported by the good fixation of the metal ring to the pelvis with screws, the adequate orientation of both components of the total hip arthroplasty, and the bone graft incorporation.

  14. Combined fractional resurfacing (10600 nm/1540 nm): Tridimensional imaging evaluation of a new device for skin rejuvenation.

    Science.gov (United States)

    Mezzana, Paolo; Valeriani, Maurizio; Valeriani, Roberto

    2016-11-01

    In this study were described the results, by tridimensional imaging evaluation, of the new "Combined Fractional Resurfacing" technique with the first fractional laser that overtakes the limits of traditional ablative, nonablative fractional resurfacing by combining CO 2 ablative and GaAs nonablative lasers. These two wavelengths can work separately or in a mixed modality to give the best treatment choice to all the patients. In this study, it is demonstrated that the simultaneous combination of the CO 2 wavelength (10600 nm) and GaAs wavelength (1540 nm) reduced the downtime, reduced pain during the treatment, and produced better results on fine wrinkles reduction and almost the same results on pigmentation as seen with 3D analysis by Antera (Miravex).

  15. Tribology of total hip arthroplasty prostheses

    Science.gov (United States)

    Rieker, Claude B.

    2016-01-01

    Articulating components should minimise the generation of wear particles in order to optimize long-term survival of the prosthesis. A good understanding of tribological properties helps the orthopaedic surgeon to choose the most suitable bearing for each individual patient. Conventional and highly cross-linked polyethylene articulating either with metal or ceramic, ceramic-on-ceramic and metal-on-metal are the most commonly used bearing combinations. All combinations of bearing surface have their advantages and disadvantages. An appraisal of the individual patient’s objectives should be part of the assessment of the best bearing surface. Cite this article: Rieker CB. Tribology of total hip arthroplasty prostheses: what an orthopaedic surgeon should know. EFORT Open Rev 2016;1:52-57. DOI: 10.1302/2058-5241.1.000004. PMID:28461928

  16. Hip Muscle Activity during Isometric Contraction of Hip Abduction

    Science.gov (United States)

    Fujisawa, Hiroyuki; Suzuki, Hiroto; Yamaguchi, Emi; Yoshiki, Hiromi; Wada, Yui; Watanabe, Aya

    2014-01-01

    [Purpose] This study aimed to determine the effect of varying hip flexion angle on hip muscle activity during isometric contraction in abduction. [Subjects] Twenty-seven healthy men (mean age=21.5 years, SD=1.2) participated in this study. [Methods] Surface electromyography (EMG) was recorded of the upper portion of the gluteus maximus (UGM), lower portion of the gluteus maximus (LGM), tensor fasciae latae (TFL), and gluteus medius (GMed) during isometric contraction under two measurement conditions: hip flexion angle (0, 20, 40, 60, and 80 degrees) and abduction of the hip joint at 20, 40, 60, and 80% maximum strength. Integrated EMG (IEMG) were calculated and normalized to the value of maximum voluntary contraction (MVC). [Results] Results indicated that the IEMG of both the UGM and LGM increased significantly with increases in hip flexion angle, whereas the IEMG of the TFL decreased significantly. The maximum activities of the UGM and the LGM were 85.7 ± 80.8%MVC and 38.2 ± 32.9%MVC at 80 degrees of hip flexion, respectively, and that of the TFL was 71.0 ± 39.0%MVC at 40 degrees of hip flexion. [Conclusion] The IEMG of the GMed did not change with increases in hip flexion angle. Hip flexion angle affected the activity of the GM and TFL during isometric contraction in abduction. PMID:24648628

  17. Hip Muscle Activity during Isometric Contraction of Hip Abduction.

    Science.gov (United States)

    Fujisawa, Hiroyuki; Suzuki, Hiroto; Yamaguchi, Emi; Yoshiki, Hiromi; Wada, Yui; Watanabe, Aya

    2014-02-01

    [Purpose] This study aimed to determine the effect of varying hip flexion angle on hip muscle activity during isometric contraction in abduction. [Subjects] Twenty-seven healthy men (mean age=21.5 years, SD=1.2) participated in this study. [Methods] Surface electromyography (EMG) was recorded of the upper portion of the gluteus maximus (UGM), lower portion of the gluteus maximus (LGM), tensor fasciae latae (TFL), and gluteus medius (GMed) during isometric contraction under two measurement conditions: hip flexion angle (0, 20, 40, 60, and 80 degrees) and abduction of the hip joint at 20, 40, 60, and 80% maximum strength. Integrated EMG (IEMG) were calculated and normalized to the value of maximum voluntary contraction (MVC). [Results] Results indicated that the IEMG of both the UGM and LGM increased significantly with increases in hip flexion angle, whereas the IEMG of the TFL decreased significantly. The maximum activities of the UGM and the LGM were 85.7 ± 80.8%MVC and 38.2 ± 32.9%MVC at 80 degrees of hip flexion, respectively, and that of the TFL was 71.0 ± 39.0%MVC at 40 degrees of hip flexion. [Conclusion] The IEMG of the GMed did not change with increases in hip flexion angle. Hip flexion angle affected the activity of the GM and TFL during isometric contraction in abduction.

  18. Partial humeral head resurfacing and Latarjet coracoid transfer for treatment of recurrent anterior glenohumeral instability.

    Science.gov (United States)

    Moros, Chris; Ahmad, Christopher S

    2009-08-01

    Bone deficiencies of either the humeral head or glenoid fossa may cause recurrent shoulder instability following soft tissue stabilization procedures. The engaging Hill-Sachs lesion, a major risk factor for instability, has been identified in a majority of patients with recurrent anterior instability. Guidance for surgical management of large humeral head deficiency presents few available options, with even fewer clinical data to support any one technique. Anteroinferior glenoid deficiency has also been a well-documented source of recurrent instability. The Latarjet coracoid transfer procedure corrects the glenoid defect by restoring the architecture of the inferior rim. Although coracoid transfer addresses containment on the glenoid, a concomitant large humeral head defect is at risk for engagement on the corrected glenoid. This article describes a case of a 50-year-old man presenting with recurrent right shoulder dislocations status post-open stabilization procedure 10 years prior. Radiologic evaluation demonstrated a large Hill-Sachs lesion with adjacent chondral derangement and a nonunion bony Bankart lesion. The Arthrosurface HemiCap humeral head resurfacing prosthesis (Arthrosurface Inc, Franklin, Massachusetts) was used to address the Hill-Sachs lesion with a Latarjet coracoid transfer procedure. We were unable to identify examples in the literature of the HemiCap used in the correction of a Hill-Sachs lesion for recurrent anterior instability. The HemiCap prosthesis has the benefit of correcting the Hill-Sachs lesion and adjacent chondral defect while preserving uninvolved articular surface. The combination of surgical interventions produced a successful result.

  19. The result of revision total hip arthroplasty in patients with metallosis following a catastrophic failure of a polyethylene liner.

    Science.gov (United States)

    Kwak, Hong Suk; Yoo, Jeong Joon; Lee, Young-Kyun; Koo, Kyung-Hoi; Yoon, Kang Sup; Kim, Hee Joong

    2015-03-01

    Wear cannot be completely prevented after total hip arthroplasty. If severe polyethylene (PE) liner wear develops, the so-called catastrophic failure occurs and metallosis develops. We postulated that longevity of the new implant may be affected after revision surgery for metallosis following a catastrophic failure of a PE liner due to the substantial amount of PE wear particles and infiltration of the metal particles in this catastrophic condition. Twenty-three hips of 23 patients were identified because they showed metallosis during revision total hip arthroplasties performed in Seoul National University Hospital between January 1996 and August 2004. They were followed for at least 6.5 years after the index revision total hip arthroplasty. The clinical and radiological results of revision total hip arthroplasties in these patients were evaluated. The median Harris hip score increased from 60 points before revision total hip arthroplasties to 90 points at the final follow-up. Osteolysis was detected at an average of 9.3 years after revision total hip arthroplasties in 13 hips and acetabular cup loosening at average 9.8 years after revision total hip arthroplasties in 9 hips. With radiographic evidence of osteolysis and loosening as the end points, the 15-year survival rates were 28.2% and 56.0%, respectively. The survival rate of revision total hip arthroplasty in patients with metallosis following a catastrophic failure of a PE liner was low.

  20. Studies of hip impingement diagnosis

    OpenAIRE

    Yazdi Far, Mahshid

    2014-01-01

    This thesis was submitted for the degree of Doctor of Philosophy and awarded by Brunel University. Hip impingement is a hip associated abnormality which develops among young and middle-aged individuals. It reduces the activity of those affected and if it is not detected at early stage, it can result in osteoarthritis. In this thesis a reliable framework for studying impingement detection is developed. Current clinical methods in detecting hip impingement involve measuring three angles, fir...

  1. Key Parameters Evaluation for Hip Prosthesis with Finite Element Analysis

    Science.gov (United States)

    Guo, Hongqiang; Li, Dichen; Lian, Qin; Li, Xiang; Jin, Zhongmin

    2007-09-01

    Stem length and cross section are two key parameters that influence the stability and longevity of metallic hip prosthesis in the total hip arthroplasty (THA). In order to assess their influence to the stress and fatigue behavior of hip prosthesis, a series model of hip prosthesis with round-shaped or drum-shaped cross section, and with different stem lengths were created. These models were analyzed under both static and dynamic loading conditions with finite element analysis, and dynamic loading represents normal walking was used in the dynamic analysis. The stress on the metallic stem, cement, and adjacent bone were got, micromotion on the cement-metal interface were got too. Safety factors for fatigue life of the hip prothesis were calculated based on data obtained from dynamic analysis. Static analysis shows that drum-shaped cross section can decrease the displacement of the stem, that stress on drum-shaped stem focus on the corner of the femoral neck and the distal part of hip prosthesis, whereas the stress on the round-shaped stem distributes evenly over most part of the stem, and maximum stress on stem prosthesis fluctuates with stem length bottoming out at stem length range from 80 mm to 110 mm, that drum-shaped stems with drum height 8 mm generate more stress at the distal part of stem than drum-shaped stems with drum height 10 mm and round stems do. Dynamic and fatigue analysis shows that drum-shaped stem with drum height 10 mm and stem length 90 mm has the greatest safety factor therefore long fatigue life.

  2. SIGN HIP construct: Achieving hip fracture fixation without using an ...

    African Journals Online (AJOL)

    At the 6 week follow-up, there was 1 (1.5%) case of infection and 8 (11.8%) cases of varus collapse. Conclusion: Using the SIGN Hip Construct, hip fracture fixation can be achieved safely without an image intensifier. This implant may be a good alternative in developing countries where access to fluoroscopy is limited or ...

  3. Formation of a large rice body-containing cyst following total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Issack Paul S

    2012-06-01

    Full Text Available Abstract Background There are several well-described causes of a painful mass following total hip arthroplasty including polyethylene and metal wear debris, infection, expanding hematoma, dislocation, and synovial cysts. In addition to causing pain, these lesions, when large enough, may cause neurologic and vascular compromise. Rapid growth of the mass may clinically and radiographically resemble a sarcoma. Here, we report a case of a large painful hip mass which developed after total hip arthroplasty. The well-circumscribed mass was overlying and extending into the hip joint containing thousands of highly organized fibrin-containing “rice bodies”. To our knowledge, this is the first report of a large, highly organized (rice-body-containing cyst complicating total hip arthroplasty. Case presentation A 55-year old Caucasian woman developed a large, slowly enlarging, painful hip mass 2 1/2 years after primary total hip arthroplasty. Clinically and radiographically, the lesion resembled a soft tissue sarcoma. Surgical removal identified a well-circumscribed mass extending into the hip joint containing thousands of highly organized fibrin-containing “rice bodies”. Conclusion Identification and excision of this “pseudotumor” following hip arthroplasty is important for obtaining a definitive diagnosis, ruling out malignancy or infection and relieving any potential compression on surrounding neurovascular structures.

  4. Hip sonography in the newborn

    International Nuclear Information System (INIS)

    Riboni, G.; Serantoni, S.; De Simoni, M.; Bascape', P.; Facchini, R.; Pirovano, G.

    1991-01-01

    The authors report the data relative to 1507 cases studied with clinical and US examinations, in the neonatal period, in order to exclude hip dysplasia dislocation. US examination was carried out according to Graf's technique and the newborns were classified according to US hip type, to clinical examination and to possible risk factors. The patients were included in a protocol including orthopedic and US controls. Seventeen treated infants were considered as pathologic. Ten of them had IIc or D hips ar birth; the other 7, with IIa hips at birth, presented a X-ray pathologic hip after the 4th months of life. At about one year of age all infants could normally walk, excpet for one who was being treated with herness. No statistically significant differences were observed between the number of pathologic infants in the risk group (1.7%) and that in the no-risk group (0.8%). Clinical examination of the newborn has low sensitivity in detecting pathologic hips. On the basis of their results, thw authors belive US examination of the newborn to be a valuable screening method to diagnose hip dysplasia/dislocation. Moreover, Graf's morphologic method is the best one for US screening of the hip in the neonatal period

  5. Hip-Hop Education Resources

    Science.gov (United States)

    Hall, Marcella Runell

    2009-01-01

    Hip-hop music and culture are often cited as being public pedagogy, meaning the music itself has intrinsic educational value. Non-profit organizations and individual educators have graciously taken the lead in utilizing hip-hop to educate. As the academy continues to debate its effectiveness, teachers and community organizers are moving forward.…

  6. Total hip arthroplasty in Denmark

    DEFF Research Database (Denmark)

    Pedersen, Alma Becic; Johnsen, Søren Paaske; Overgaard, Søren

    2005-01-01

    The annual number of total hip arthroplasties (THA) has increased in Denmark over the past 15 years. There is, however, limited detailed data available on the incidence of THAs.......The annual number of total hip arthroplasties (THA) has increased in Denmark over the past 15 years. There is, however, limited detailed data available on the incidence of THAs....

  7. The current state of bearing surfaces in total hip replacement.

    Science.gov (United States)

    Rajpura, A; Kendoff, D; Board, T N

    2014-02-01

    We reviewed the literature on the currently available choices of bearing surface in total hip replacement (THR). We present a detailed description of the properties of articulating surfaces review the understanding of the advantages and disadvantages of existing bearing couples. Recent technological developments in the field of polyethylene and ceramics have altered the risk of fracture and the rate of wear, although the use of metal-on-metal bearings has largely fallen out of favour, owing to concerns about reactions to metal debris. As expected, all bearing surface combinations have advantages and disadvantages. A patient-based approach is recommended, balancing the risks of different options against an individual's functional demands.

  8. Development and first validation of a simplified CT-based classification system of soft tissue changes in large-head metal-on-metal total hip replacement: intra- and interrater reliability and association with revision rates in a uniform cohort of 664 arthroplasties

    International Nuclear Information System (INIS)

    Boomsma, Martijn F.; Warringa, Niek; Edens, Mireille A.; Lingen, Christiaan P. van; Ettema, Harmen B.; Verheyen, Cees C.P.M.; Maas, Mario

    2015-01-01

    After implantation of a metal-on-metal total hip arthroplasty (MoM THA), a large incidence of pseudotumor formation has been described recently. Several centers have invited patients for follow-up in order to screen for pseudotumor formation. The spectrum of abnormalities found by CT in MoM THA patients can be unfamiliar to radiologists and orthopedic surgeons. Previously, a CT five-point grading scale has been published. In this paper, a simplification into a three-point classification system gives insight in the morphological distinction of abnormalities of the postoperative hip capsule in MoM implants in relation to the decision for revision. The reliability of this simplified classification regarding intra- and interrater reliability and its association with revision rate is investigated and discussed. All patients who underwent MoM THA in our hospital were invited for screening. Various clinical measures and CT scan were obtained in a cross-sectional fashion. A decision on revision surgery was made shortly after screening. CT scans were read in 582 patients, of which 82 patients were treated bilaterally. CT scans were independently single read by two board-certified radiologists and classified into categories I-V. In a second meeting, consensus was obtained. Categories were subsequently rubricated in class A (categories I and II), B (category III), and C (categories IV and V). Intra- and inter-radiologist agreement on MoM pathology was assessed by means of the weighted Cohen's kappa. Categorical data were presented as n (%), and tested by means of Fisher's exact test. Continuous data were presented as median (min-max) and tested by means of Mann-Whitney U test (two group comparison) or Kruskal-Wallis test (three group comparison). Logistic regression analysis was performed in order to study independence of CT class for association with revision surgery. Univariate statistically significant variables were entered in a multiple model. All statistical

  9. Development and first validation of a simplified CT-based classification system of soft tissue changes in large-head metal-on-metal total hip replacement: intra- and interrater reliability and association with revision rates in a uniform cohort of 664 arthroplasties

    Energy Technology Data Exchange (ETDEWEB)

    Boomsma, Martijn F.; Warringa, Niek [Isala Hospital, Department of Radiology, Zwolle (Netherlands); Edens, Mireille A. [Isala Hospital, Department of Innovation and Science, Zwolle (Netherlands); Lingen, Christiaan P. van; Ettema, Harmen B.; Verheyen, Cees C.P.M. [Isala Hospital, Department of Orthopaedics, Zwolle (Netherlands); Maas, Mario [AMC, Department of Radiology, Amsterdam (Netherlands)

    2015-08-15

    After implantation of a metal-on-metal total hip arthroplasty (MoM THA), a large incidence of pseudotumor formation has been described recently. Several centers have invited patients for follow-up in order to screen for pseudotumor formation. The spectrum of abnormalities found by CT in MoM THA patients can be unfamiliar to radiologists and orthopedic surgeons. Previously, a CT five-point grading scale has been published. In this paper, a simplification into a three-point classification system gives insight in the morphological distinction of abnormalities of the postoperative hip capsule in MoM implants in relation to the decision for revision. The reliability of this simplified classification regarding intra- and interrater reliability and its association with revision rate is investigated and discussed. All patients who underwent MoM THA in our hospital were invited for screening. Various clinical measures and CT scan were obtained in a cross-sectional fashion. A decision on revision surgery was made shortly after screening. CT scans were read in 582 patients, of which 82 patients were treated bilaterally. CT scans were independently single read by two board-certified radiologists and classified into categories I-V. In a second meeting, consensus was obtained. Categories were subsequently rubricated in class A (categories I and II), B (category III), and C (categories IV and V). Intra- and inter-radiologist agreement on MoM pathology was assessed by means of the weighted Cohen's kappa. Categorical data were presented as n (%), and tested by means of Fisher's exact test. Continuous data were presented as median (min-max) and tested by means of Mann-Whitney U test (two group comparison) or Kruskal-Wallis test (three group comparison). Logistic regression analysis was performed in order to study independence of CT class for association with revision surgery. Univariate statistically significant variables were entered in a multiple model. All statistical

  10. The efficacy of patellar decompression for improving anterior knee pain following total knee arthroplasty without patellar resurfacing.

    Science.gov (United States)

    Lee, Gun Woo; Lee, Sun-Mi; Jang, Soo-Jin; Son, Jung-Hwan

    2013-04-01

    Anterior knee pain remains common following total knee arthroplasty (TKA). In this study, we evaluated the efficacy of patellar decompression via drilling for the treatment of anterior knee pain following TKA without patellar resurfacing. A prospective cohort study was performed in 271 consecutive patients who underwent primary total knee replacement with patellar decompression (study group, n = 131) or without decompression (control group, n = 140). The patients were assessed according to the Knee Society rating, clinical anterior knee pain score, and British Orthopaedic Association patient-satisfaction score in each group. Each assessment was performed without the examiner knowing whether the patella had been decompressed. Radiographic evaluations were also performed according to the Knee Society scoring system for functional activity and our own severity grade system for patellofemoral articular change. There were no adverse events following patellar decompression. The overall prevalence of anterior knee pain was not significantly different between groups (p = 0.71). However, patients presenting pain over grade II after the operation in the study group were statistically low (p = 0.01). The overall postoperative knee scores were higher in the study group, but there were no significant differences between groups (p = 0.0731). Analyses of the radiographs revealed similar postoperative outcomes in both groups of knees. As we observed significantly lower rates of anterior knee pain and no patellar complications following patellar decompression via drilling in TKA without patellar resurfacing, we recommend performing patellar decompression in cases of total knee replacement without patellar resurfacing.

  11. Alumina-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty.

    Science.gov (United States)

    Jung, Yup Lee; Kim, Shin-Yoon

    2010-02-11

    The long-term durability of polyethylene lining total hip arthroplasty (THA) mainly depends on periprosthetic osteolysis due to wear particles, especially in young active patients. In hip simulator study, reports revealed significant wear reduction of the alumina ceramic-on-polyethylene articulation of THA compared with metal-on-polyethylene bearing surfaces. However, medium to long-term clinical studies of THA using the alumina ceramic-on-polyethylene are few and the reported wear rate of this articulation is variable. We reviewed the advantages and disadvantages of ceramicon- polyethylene articulation in THA, hip simulator study and retrieval study for polyethylene wear, in vivo clinical results of THA using alumina ceramic-on-polyethylene bearing surfaces in the literature, and new trial alumina ceramic-onhighly cross linked polyethylene bearing surfaces.

  12. Clinical diagnosis of hip pain.

    Science.gov (United States)

    Plante, Matthew; Wallace, Roxanne; Busconi, Brian D

    2011-04-01

    This article reviews the evaluation of the hip including the clinical history and physical examination. As our understanding of hip pathology evolves, and arthroscopic and other minimally invasive operative techniques improve, the focus is shifting toward earlier identification of hip pathology. Risk factors for the development of arthritis are now well established and include femoral acetabular impingement, labral tearing, developmental dysplasia, and slipped capital femoral epiphysis. Emerging treatment options may address these conditions in the early stages and prevent or slow the progression of hip degeneration. It is vitally important to elucidate intra-articular versus extra-articular pathology of hip pain in every step of the patient encounter: history, physical examination, and imaging. Copyright © 2011 Elsevier Inc. All rights reserved.

  13. Total hip arthroplasty for surgical management of advanced tuberculous hip arthritis: Case report

    OpenAIRE

    Tan, Shi Ming; Chin, Pak Lin

    2015-01-01

    Tuberculosis (TB) arthritis of the hip is a debilitating disease that often results in severe cartilage destruction and degeneration of the hip. In advanced cases, arthrodesis of the hip confers benefits to the young, high-demand and active patient. However, many of these patients go on to develop degenerative arthritis of the spine, ipsilateral knee and contralateral hip, necessitating the need for a conversion to total hip arthroplasty. Conversion of a previously fused hip to a total hip ar...

  14. Hip abductor muscle volume in hip osteoarthritis and matched controls.

    Science.gov (United States)

    Zacharias, A; Pizzari, T; English, D J; Kapakoulakis, T; Green, R A

    2016-10-01

    Hip abductor muscle strength and function is negatively impacted by the presence of hip osteoarthritis (OA). This study aimed to quantify differences in hip abductor muscle volume, fatty infiltration and strength in a unilateral hip OA population when compared to a control group. Impact of radiographic severity of OA on these variables was also examined. Volumes of gluteus maximus (GMax), medius (GMed) minimus (GMin) and tensor fascia lata (TFL) was measured using MRI and muscle volume asymmetry between limbs was calculated. Fatty infiltrate within muscles was graded using the Goutallier classification system. Hip abduction and rotation strength was tested using a dynamometer. Differences between groups or limbs were analysed using t-tests and differences in fatty infiltration using non-parametric tests. A statistically significant decrease in muscle volume was identified in GMax (P abduction and internal rotation strength was reduced in the OA group. Increased levels of fatty infiltration were identified in the affected limbs of the OA group for GMax (P = 0.01) and GMin (P = 0.04). Gluteal muscle atrophy, increased gluteal fatty infiltration and hip strength deficits were evident in the affected hips of OA participants. Since severity of OA was related to the extent of atrophy and fatty deposits, rehabilitation programs targeting these muscles could reverse or halt the progression of these structural and functional deficits. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  15. Extensive risk analysis of mechanical failure for an epiphyseal hip prothesis: a combined numerical-experimental approach.

    Science.gov (United States)

    Martelli, S; Taddei, F; Cristofolini, L; Gill, H S; Viceconti, M

    2011-02-01

    There has been recent renewed interest in proximal femur epiphyseal replacement as an alternative to conventional total hip replacement. In many branches of engineering, risk analysis has proved to be an efficient tool for avoiding premature failures of innovative devices. An extensive risk analysis procedure has been developed for epiphyseal hip prostheses and the predictions of this method have been compared to the known clinical outcomes of a well-established contemporary design, namely hip resurfacing devices. Clinical scenarios leading to revision (i.e. loosening, neck fracture and failure of the prosthetic component) were associated with potential failure modes (i.e. overload, fatigue, wear, fibrotic tissue differentiation and bone remodelling). Driving parameters of the corresponding failure mode were identified together with their safe thresholds. For each failure mode, a failure criterion was identified and studied under the most relevant physiological loading conditions. All failure modes were investigated with the most suitable investigation tool, either numerical or experimental. Results showed a low risk for each failure scenario either in the immediate postoperative period or in the long term. These findings are in agreement with those reported by the majority of clinical studies for correctly implanted devices. Although further work is needed to confirm the predictions of this method, it was concluded that the proposed risk analysis procedure has the potential to increase the efficacy of preclinical validation protocols for new epiphyseal replacement devices.

  16. Clinical Evaluation of Fused/Ankylosed Hip with Severe Flexion Deformity after Conversion to Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Saroj Kumar Suwal

    2016-06-01

    Conclusions: THA is an effective treatment for ankylosed hip with severe flexion deformity although complications are noted more than routine hip arthroplasties. Keywords: ankylosed hip; fused hip; severe flexion deformity; total hip arthroplasty. | PubMed

  17. Results of total hip arthroplasty using a bionic hip stem.

    Science.gov (United States)

    Fokter, Samo K; Sarler, Taras; Strahovnik, Andrej; Repše-Fokter, Alenka

    2015-06-01

    The trabecular-orientated bionic hip stem was designed to mimic the natural force transmission through the femur in total hip arthroplasty, resulting in supposedly longer prosthesis survivability. The aim of this study was to compare the second-generation bionic hip stem to a standard uncemented hip stem. A group of 18 patients (21 hips) who underwent total hip arthroplasty with a bionic stem (bionic group) was compared with a historic group of 12 patients (12 hips) treated with standard anatomic hip stem (control group). During the first year after the procedure, the densitometric measurements of the bone around the prosthesis were taken. Radiographic and clinical assessments were additionally performed preoperatively and at the three month, six month, one year and three year follow-ups in the bionic group. In the bionic group, one patient was revised for aseptic loosening and 16 patients (19 hips) were available to the final follow-up. A significant decrease of bone mineral density was found in Gruen zones 3, 4 and 5 in the bionic group, and in zone 7 in both groups. The bionic group had a significantly higher bone mineral density in Gruen zone 1 at the one year follow-up. At the final follow-up, all prostheses were radiologically stable in both groups. Provided that a good implant position is achieved, comparable short-term results can be obtained using a bionic stem. Still, a decrease of bone mineral density in Gruen zone 7 occurred in both groups. Further studies are required to determine survivability of the bionic stem.

  18. The impact of surface and geometry on coefficient of friction of artificial hip joints.

    Science.gov (United States)

    Choudhury, Dipankar; Vrbka, Martin; Mamat, Azuddin Bin; Stavness, Ian; Roy, Chanchal K; Mootanah, Rajshree; Krupka, Ivan

    2017-08-01

    Coefficient of friction (COF) tests were conducted on 28-mm and 36-mm-diameter hip joint prostheses for four different material combinations, with or without the presence of Ultra High Molecular Weight Polyethylene (UHMWPE) particles using a novel pendulum hip simulator. The effects of three micro dimpled arrays on femoral head against a polyethylene and a metallic cup were also investigated. Clearance played a vital role in the COF of ceramic on polyethylene and ceramic on ceramic artificial hip joints. Micro dimpled metallic femoral heads yielded higher COF against a polyethylene cup; however, with metal on metal prostheses the dimpled arrays significantly reduced the COF. In situ images revealed evidence that the dimple arrays enhanced film formation, which was the main mechanism that contributed to reduced friction. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Total Hip Arthroplasty Dislocations Are More Complex Than They Appear: A Case Report of Intraprosthetic Dislocation of an Anatomic Dual-Mobility Implant After Closed Reduction

    Science.gov (United States)

    Waddell, Bradford S.; De Martino, Ivan; Sculco, Thomas; Sculco, Peter

    2016-01-01

    Background: Total hip arthroplasty is a successful operation for the treatment of hip pain. One of the common complications of hip arthroplasty is dislocation. While reduction of standard prosthetic dislocations is highly successful, new prostheses add the potential for new complications. Case Report: We present the case of a patient who experienced intraprosthetic dislocation of an anatomic dual-mobility total hip prosthesis after a closed hip reduction and include the prereduction and postreduction radiographic findings. Conclusion: Emergency department physicians should be aware of intraprosthetic dislocation. This complication can be easily missed because the metal/ceramic femoral head appears to be reduced in the acetabulum. PMID:27303232

  20. The pelvis and hips

    International Nuclear Information System (INIS)

    Berquist, T.H.; Coventry, M.B.

    1985-01-01

    Radiographic evaluation of joint replacements requires close communication between the radiologist and referring physician. Routine films, radioisotope scans, and subtraction arthrography (including aspiration and injection of the pseudocapsule) may be indicated in different clinical situations. This paper summarizes the accuracy of these modalities. Most patients present with pain. One must exclude loosening, infection, and other problems. The arthrogram is most useful in defining anatomy and most causes of hip pain. Culture studies and diagnostic injections add to the versatility of subtraction arthrography and increase its accuracy. If plain films are negative, a Tc-99m scan can be obtained. If this is negative, loosening is unlikely. If pain persists or if the scan is positive, an arthrogram should be performed. Pain may be secondary to bursitis rather than loosening, and the arthrogram will assist in diagnosis and treatment. When films suggest loosening, arthrography is the procedure of choice to confirm the diagnosis and to exclude infection

  1. Hip complications following chemoradiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, P.J.; Sebag Montefiore, D.J.; Arnott, S.J. [Saint Bartholomew`s Hospital, London (United Kingdom)

    1995-12-01

    Chemoradiotherapy protocols are a recent development in the management of tumours where preservation of organ function is important. It is now recognized that such combined treatment may produce adverse effects below the accepted dose thresholds for either modality. This enhancement of toxicity is generally thought to reflect depletion of stem cells within the tissue concerned. We report four patients who have developed avascular necrosis or fractures of the hip following chemoradiotherapy for carcinoma of the vulva or anus. These complications developed after a radiation dose of 4500 cGy in 20 fractions. The possible role of cytotoxic agents in sensitizing bone to radiation damage is discussed, and a novel mechanism is proposed to account for this phenomenon. (author).

  2. Hip complications following chemoradiotherapy

    International Nuclear Information System (INIS)

    Jenkins, P.J.; Sebag Montefiore, D.J.; Arnott, S.J.

    1995-01-01

    Chemoradiotherapy protocols are a recent development in the management of tumours where preservation of organ function is important. It is now recognized that such combined treatment may produce adverse effects below the accepted dose thresholds for either modality. This enhancement of toxicity is generally thought to reflect depletion of stem cells within the tissue concerned. We report four patients who have developed avascular necrosis or fractures of the hip following chemoradiotherapy for carcinoma of the vulva or anus. These complications developed after a radiation dose of 4500 cGy in 20 fractions. The possible role of cytotoxic agents in sensitizing bone to radiation damage is discussed, and a novel mechanism is proposed to account for this phenomenon. (author)

  3. [Modified mini-Hardinge access for hip prosthesis implantation in the supine position].

    Science.gov (United States)

    Mazoochian, F; Schmidutz, F; Fottner, A; Jansson, V

    2014-04-01

    Total hip arthroplasty with a minimal-incision technique that can be performed in the widely used supine position. The accustomed and good overview of this position allows safe positioning of the implant and combines this with the advantage of a soft tissue preserving technique. All standard instruments and implants can be further applied. Primary and secondary coxarthrosis, femoral head necrosis. Revision surgery, severe anatomic deformity, implantation of hip resurfacing arthroplasty. Supine position. The skin incision runs from the innominate tubercle proximally and falls slightly in the dorsal direction (20-30°). Incision of the iliotibial tract and exposure of the vastogluteal muscle sling. Starting from the greater trochanter, the sinewy onset of the minimal and medium gluteal muscle is split with an arched-shaped incision, which also falls proximally in the dorsal direction. Exposition of the joint capsule, longitudinal incision and resection of the ventrolateral parts. Dislocation of the hip by a combined adduction and external rotation movement. Osteotomy of the femoral neck and resection of the femoral head are performed in a figure-of-four position without adduction. To prepare the acetabulum and to insert the cup, the leg is placed in neutral position with a slight flexion of 20° in the hip. Preparation of the femur and implantation of the stem is again performed in a figure-of-four position in adduction. Reduction of the hip and stepwise wound closure. Mobilization on postoperative day 1. Starting with half weight bearing and after completed wound healing rapid increase to full weight bearing. Intensive physiotherapy and rehabilitation. Thrombosis prophylaxis according to guidelines. The mini-incision approach has successfully been used in our clinic for years. Between September 2004 and November 2005, the less-invasive technique was evaluated in a randomized controlled trial with 51 patients (52 hips). Compared to the standard approach a

  4. To debride or not to debride? That is the question: rethinking char removal in ablative CO2 laser skin resurfacing.

    Science.gov (United States)

    Niamtu, Joe

    2008-09-01

    The treatment standard for laser skin resurfacing (LSR) includes aggressively wiping away the char with moist gauze before and after each pass to prevent heat buildup and lateral tissue damage from existing char. No published study has addressed not debriding between passes with traditional higher fluence, high-density, multipass CO(2) LSR in humans. The objective was to disprove the dogma that wiping away the laser char between treatment passes is necessary. A total of 158 patients were treated over a 23-month period with multipass, nondebrided CO(2) laser resurfacing (6 J/cm(2), density 6). A small series of split-face studies were performed by debriding one side and not debriding the other side after each pass, and 89 full-face patients were treated without debriding any char between two or three passes. Histologic and photographic studies were performed in selected patients to determine the differences between debrided and nondebrided techniques. None of the nondebrided patients experienced significant complications. Operative times were shortened as was postlaser pain and erythema. Histologic analysis showed that three passes of 6 J/cm(2) with a density of 6 produces extremely similar epidermal and dermal changes regardless of debriding between passes or not. This is the first study in humans using high-energy, high-density, multipass LSR without debriding between passes. The authors have indicated no significant interest with commercial supporters.

  5. The effect of wiping on skin resurfacing in a pig model using a high energy pulsed CO2 laser system.

    Science.gov (United States)

    Ross, E V; Mowlavi, A; Barnette, D; Glatter, R D; Grevelink, J M

    1999-02-01

    The impact of wiping in laser skin resurfacing has not been systematically studied. We examined the effects of wiping during single- and multiple-pass high energy pulsed CO2 laser skin resurfacing in a farm pig. Consequences of wiping were evaluated with regard to depth of residual thermal damage, tissue necrosis, and fibroplasia. Also, the impact of wiping on gross wound healing was observed. Wounds were followed for 21 days and biopsies were obtained on postoperative days 0, 1, and 21. Immediate postoperative biopsies of single-pass wounds showed equivalent residual thermal damage regardless of wiping; in contrast, biopsies from multiple-pass sites without wiping showed more extensive and variable residual thermal damage than wiped sites. On postoperative day one, single pass sites without wiping were grossly less erythematous than wiped sites, and biopsies showed less extensive necrosis and inflammation. In contrast, multiple pass sites without wiping were grossly more erythematous than corresponding wiped sites, and biopsies revealed significantly increased and variable necrosis. After 21 days, multiple pass sites without wiping were grossly more erythematous and showed a thicker band of fibroplasia microscopy. For single pass wounds, not wiping decreased the level of wounding. In contrast, not wiping in multiple pass wounds significantly increased the depth and variability of residual thermal damage and necrosis, resulting in prolonged healing.

  6. Comparison of radiographic and radionuclide hip arthrography in determination of femoral component loosening of hip arthroplasties

    International Nuclear Information System (INIS)

    Capello, W.N.; Uri, B.G.; Wellman, H.N.; Robb, J.A.; Stiver, P.L.

    1985-01-01

    Radiographic examination of a patient experiencing pain following total hip arthroplasty is an important step in the systematic approach to evaluating component loosening, even though the information yielded is often equivocal and nondiagnostic in assessing component loosening. The radiographic criteria for loosening are especially difficult to assess following revision surgery, for radiolucent lines frequently exist at the bone-cement interface immediately following implantation. The advent of noncemented hip prostheses poses another problem: the routinely noted disruption of bone-cement of prosthesis-cement interfaces is not present with uncemented prostheses. As the criteria for loosening of the noncemented prostheses are still evolving, plain radiographic examination is frequently nondiagnostic. Femoral component loosening is difficult to detect with standard contrast arthrography because the bone, metal, surrounding radiopaque cement and contrast agents have similar or identical radiographic appearances. In contrast arthrography, if the prosthesis is loose the injected agent opacifies the radiolucent zone encircling the prosthesis or cement mangle. Because of the similarity in the appearances of these agents and the surrounding structures on x-ray films, interpretation is difficult. The inclusion of subtraction techniques in routine contrast arthrography has improved its accuracy; however, these techniques require special equipment and demand precise patient positioning. The purpose of this study is to introduce a new form of hip arthrography using a radionuclide agent in place of the contrast agent. A comparison of the results using these two techniques is presented

  7. Traumatic injuries of the hip.

    LENUS (Irish Health Repository)

    Marshall, Nina

    2009-11-01

    Traumatic lesions of the hip in athletes may be clinically challenging because of the overlap in clinical presentation due to differing pathologies and the presence of multiple injuries. Imaging of the hip in the athlete has undergone a recent resurgence of interest and understanding related to the increasing accessibility and use of hip arthroscopy, which expands the treatment options available for intra-articular pathology. MR imaging and MR arthrography have a unique role in diagnosis of these pathologies, guiding the surgeon, arthroscopist, and referring clinician in their management of bony and soft tissue injury.

  8. Hip Muscle Activity during Isometric Contraction of Hip Abduction

    OpenAIRE

    Fujisawa, Hiroyuki; Suzuki, Hiroto; Yamaguchi, Emi; Yoshiki, Hiromi; Wada, Yui; Watanabe, Aya

    2014-01-01

    [Purpose] This study aimed to determine the effect of varying hip flexion angle on hip muscle activity during isometric contraction in abduction. [Subjects] Twenty-seven healthy men (mean age=21.5 years, SD=1.2) participated in this study. [Methods] Surface electromyography (EMG) was recorded of the upper portion of the gluteus maximus (UGM), lower portion of the gluteus maximus (LGM), tensor fasciae latae (TFL), and gluteus medius (GMed) during isometric contraction under two measurement con...

  9. Simulated studies of wear and friction in total hip prosthesis components with various ball sizes and surface finishes

    Science.gov (United States)

    Swikert, M. A.; Johnson, R. L.

    1976-01-01

    Experiments were conducted on a newly designed total hip joint simulator. The apparatus closely simulates the complex motions and loads of the human hip in normal walking. The wear and friction of presently used appliance configurations and materials were determined. A surface treatment of the metal femoral ball specimens was applied to influence wear. The results of the investigation indicate that wear can be reduced by mechanical treatment of metal femoral ball surfaces. A metallographic examination and surface roughness measurements were made.

  10. CUSTOMIZED ACETABULAR COMPONENTS IN REVISION HIP ARTHROPLASTY

    Directory of Open Access Journals (Sweden)

    G. M. Kavalersky

    2016-01-01

    Full Text Available In recent years, there is a trend of increasing demand for revision hip arthroplasty. Among these patients there are many with complex acetabular defects, including patients with pelvic discontinuity. To ensure stability for revised acetabular components in such cases becomes a challenging or unachievable task. Such defects give indications for printing customized tri-flange acetabular component. The authors analysed own experience of creating and applying custom made acetabular components in 3 patients with complex acetabular defects. Material and methods. Among the patients there were 2 women and 1 man. Average age was 60,3±19,4 years (38 to 78 years. Two patients had III B defects with pelvic discontinuity and one patient had III A defect by Paprosky classification. As the first step, the authors in collaboration with engineers printed a plaster full size pelvic 3D model, as the second step a customized tri-flange acetabular component was designed and printed. Harris Hip Score was evaluated preoperatively and 3 months postoperatively. Results. Average follow-up period was 5,3±2,5 months (3 to 8 months. The authors observed no cases of implant loosening, dislocation or deep periprosthetic infection. Average Harris Hip Score before surgery was 27,13 and after surgery – 74,1 indicating a significant improvement in 3 months postoperatively. Conclusion. Indications for use of individual acetabular components in reported patients correspond to indications formulated by Berasi et al. The authors obtained encouraging early follow-up outcomes that correspond to data of other authors. In one patient certain difficulties were reported due to insufficient pelvic distraction. Component’s flanges prevented achieving adequate pelvic distraction. Nevertheless, good primary stability was achieved. Modern software and 3D metal printers can significantly reduce the production cost of customized acetabular components. Application of this technology can be

  11. Association of hip pain with radiographic evidence of hip osteoarthritis: diagnostic test study

    Science.gov (United States)

    Nevitt, Michael C; Niu, Jingbo; Clancy, Mary M; Lane, Nancy E; Link, Thomas M; Vlad, Steven; Tolstykh, Irina; Jungmann, Pia M.; Felson, David T; Guermazi, Ali

    2015-01-01

    Study question Is there concordance between hip pain and radiographic hip osteoarthritis? Methods In this diagnostic test study, pelvic radiographs were assessed for hip osteoarthritis in two cohorts: the Framingham Osteoarthritis Study (community of Framingham, Massachusetts) and the Osteoarthritis Initiative (a multicenter longitudinal cohort study of osteoarthritis in the United States). Using visual representation of the hip joint, participants reported whether they had hip pain on most days and the location of the pain: anterior, groin, lateral, buttocks, or low back. In the Framingham study, participants with hip pain were also examined for hip pain with internal rotation. The authors analysed the agreement between radiographic hip osteoarthritis and hip pain, and for those with hip pain suggestive of hip osteoarthritis they calculated the sensitivity, specificity, positive predictive value, and negative predictive value of radiographs as the diagnostic test. Study answer and limitations In the Framingham study (n=946), only 15.6% of hips in patients with frequent hip pain showed radiographic evidence of hip osteoarthritis, and 20.7% of hips with radiographic hip osteoarthritis were frequently painful. The sensitivity of radiographic hip osteoarthritis for hip pain localised to the groin was 36.7%, specificity 90.5%, positive predictive value 6.0%, and negative predictive value 98.9%. Results did not differ much for hip pain at other locations or for painful internal rotation. In the Osteoarthritis Initiative study (n=4366), only 9.1% of hips in patients with frequent pain showed radiographic hip osteoarthritis, and 23.8% of hips with radiographic hip osteoarthritis were frequently painful. The sensitivity of definite radiographic hip osteoarthritis for hip pain localised to the groin was 16.5%, specificity 94.0%, positive predictive value 7.1%, and negative predictive value 97.6%. Results also did not differ much for hip pain at other locations. What this

  12. Hip Fractures among Older Adults

    Science.gov (United States)

    ... this page: About CDC.gov . Home & Recreational Safety Older Adult Falls Important Facts about Falls Costs of Falls Hip Fractures Among Older Adults Older Adult Falls Programs Compendium of Effective Fall Interventions, 3rd Edition ...

  13. Social inequality and hip fracture

    DEFF Research Database (Denmark)

    Harvey, N. C.; Hansen, L.; Judge, A.

    2015-01-01

    fracture (ICD10: S720, S721, S722 and S729) were identified from 1 January 1995 to 31 December 2011. Hip fracture patients were matched 1:1 on age, gender and year of fracture to a non-hip fracture control. An individual's education attainment was defined as basic, secondary or higher, and their income...... and year of fracture, and education and year of fracture, to describe whether the association of income or education with rates of hip fracture changed over time. Results: There were 69,774 hip fracture patients and 69,709 controls (both mean age 81.2 years) with complete data on income and education. Both...

  14. Developmental Dysplasia of the Hip

    Science.gov (United States)

    ... to deepen the hip socket (if it's too shallow) or to shorten the thighbone or realign it. ... and treatment, consult your doctor. © 1995- The Nemours Foundation. All rights reserved. Images provided by The Nemours ...

  15. Monoarticular Hip Involvement in Pseudogout

    Directory of Open Access Journals (Sweden)

    Figen Kocyigit

    2015-01-01

    Full Text Available Pseudogout is the acutest form of arthritis in the elderly. Although clinical manifestations vary widely, polyarticular involvement is typical mimicking osteoarthritis or rheumatoid arthritis. Monoarticular involvement is relatively rare and is generally provoked by another medical condition. There are reported cases of hip involvement by pseudogout in monoarticular form. However, all of the cases were presented as septic arthritis. In this report, we present a case of monoarticular hip involvement mimicking soft tissue abscess. We confirmed the pseudogout diagnosis after ultrasonographic evaluation of the involved hip joint and pathological and biochemical analysis of synovial fluid analysis. Diagnosis is important to avoid unnecessary medical and surgical treatment in cases of the bizarre involvement of hip in pseudogout.

  16. Artroplastía de superficie en cadera. Resultados iniciales favorables en pacientes selectos. [Hip resurfacing arthroplasty: favorable initial results in selected patients

    Directory of Open Access Journals (Sweden)

    Fernando Martín Comba

    2013-12-01

    Full Text Available In­tro­duc­ción El objetivo del presente trabajo es reportar los resultados clínicos y radiológicos iniciales de una serie consecutiva de pacientes selectos tratados en nuestra institución con un único diseño de artroplastia de superficie, comparando además la tasa de revisión temprana con un grupo control de pacientes tratados en el mismo lapso con una artroplastia total de cadera no cementada. Material y ­Métodos Cuarenta y siete pacientes de sexo masculino (49 caderas con diagnóstico de artrosis de cadera que fueron tratados quirúrgicamente con una artroplastia híbrida de superficie, entre noviembre de 2006 y julio de 2009. La edad promedio fue de 44,5 años (rango de 21 a 57. En todos los casos, la indicación de la artroplastia de superficie se realizó en pacientes jóvenes con alta expectativa funcional y siguiendo estrictos criterios de selección radiológicos. Se efectuó un seguimiento clínico y un meticuloso análisis radiológico. Resultados La escala funcional posoperatoria de Merle D’Aubigné-Postel fue, en promedio, de 17,3 puntos a los 43 meses de seguimiento promedio (rango 24-62 meses. El 85% de los pacientes refirió que practicaba alguna actividad deportiva con una escala UCLA promedio de 9,5 (rango 8-10. Un paciente requirió una cirugía de revisión (2,04% por fractura de cuello femoral. No existieron diferencias estadísticamente significativas en cuanto a la tasa de revisión temprana comparando con el grupo control (p = 0,55. Conclusiones En nuestra experiencia inicial con artroplastia de superficie, obtuvimos resultados a corto plazo favorables, en una serie de hombres con artrosis y alta demanda funcional, estrictamente seleccionados.

  17. Influence of Hip Joint Position on Muscle Activity during Prone Hip Extension with Knee Flexion.

    Science.gov (United States)

    Suehiro, Tadanobu; Mizutani, Masatoshi; Okamoto, Mitsuhisa; Ishida, Hiroshi; Kobara, Kenichi; Fujita, Daisuke; Osaka, Hiroshi; Takahashi, Hisashi; Watanabe, Susumu

    2014-12-01

    [Purpose] This study investigated the selective activation of the gluteus maximus during a prone hip extension with knee flexion exercise, with the hip joint in different positions. [Subjects] The subjects were 21 healthy, male volunteers. [Methods] Activities of the right gluteus maximus, right hamstrings, bilateral lumbar erector spinae, and bilateral lumbar multifidus were measured using surface electromyography during a prone hip extension with knee flexion exercise. Measurements were made with the hip joint in each of 3 positions: (1) a neutral hip joint position, (2) an abduction hip joint position, and (3) an abduction with external rotation hip joint position. [Results] Gluteus maximus activity was significantly higher when the hip was in the abduction with external rotation hip joint position than when it was in the neutral hip joint and abduction hip joint positions. Gluteus maximus activity was also significantly higher in the abduction hip joint position than in the neutral hip joint position. Hamstring activity was significantly lower when the hip was in the abduction with external rotation hip joint position than when it was in the neutral hip joint and abduction hip joint positions. [Conclusion] Abduction and external rotation of the hip during prone hip extension with knee flexion exercise selectively activates the gluteus maximus.

  18. Fixation of an Anatomically Designed Cementless Stem in Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Shigeru Nakamura

    2012-01-01

    Full Text Available Purpose. The Anatomic Fiber Metal plus stem (Zimmer is one of the anatomically designed cementless stems to achieve stable fixation by metaphyseal fit. We studied outcomes of cementless total hip arthroplasty using this stem and possible effects of metaphyseal fit on outcomes. Methods. The cementless total hip arthroplasty using this stem was performed for 155 hips. One hundred and thirty-seven hips of 122 patients were followed for 5 to 16 (mean, 9.7 years and entered into the study. The metaphyseal fit was defined as good or poor in an anteroposterior radiograph after surgery. We studied the fixation of the stem and bone reaction on an anteroposterior radiograph at the final followup. Results. Twelve hips had revision, six acetabular components and six acetabular liners. No stem was revised. The biological fixation of the stem was bone ingrown fixation for 136 hips and unstable for one. The metaphyseal fit was good for 83 hips and poor for 54 hips. There were no differences for stem fixation and bone reaction between the two groups. Conclusions. The fixation of the stem was stable at a mean followup of 9.7 years independently from metaphyseal fit.

  19. Numerical evaluation of bone remodelling and adaptation considering different hip prosthesis designs.

    Science.gov (United States)

    Levadnyi, Ievgen; Awrejcewicz, Jan; Gubaua, José Eduardo; Pereira, Jucélio Tomás

    2017-12-01

    The change in mechanical properties of femoral cortical bone tissue surrounding the stem of the hip endoprosthesis is one of the causes of implant instability. We present an analysis used to determine the best conditions for long-term functioning of the bone-implant system, which will lead to improvement of treatment results. In the present paper, a finite element method coupled with a bone remodelling model is used to evaluate how different three-dimensional prosthesis models influence distribution of the density of bone tissue. The remodelling process begins after the density field is obtained from a computed tomography scan. Then, an isotropic Stanford model is employed to solve the bone remodelling process and verify bone tissue adaptation in relation to different prosthesis models. The study results show that the long-stem models tend not to transmit loads to proximal regions of bone, which causes the stress-shielding effect. Short stems or application in the calcar region provide a favourable environment for transfer of loads to the proximal region, which allows for maintenance of bone density and, in some cases, for a positive variation, which causes absence of the aseptic loosening of an implant. In the case of hip resurfacing, bone mineral density changes slightly and is closest to an intact femur. Installation of an implant modifies density distribution and stress field in the bone. Thus, bone tissue is stimulated in a different way than before total hip replacement, which evidences Wolff's law, according to which bone tissue adapts itself to the loads imposed on it. The results suggest that potential stress shielding in the proximal femur and cortical hypertrophy in the distal femur may, in part, be reduced through the use of shorter stems, instead of long ones, provided stem fixation is adequate. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Imaging of the hip

    International Nuclear Information System (INIS)

    Karantanas, A.

    2012-01-01

    Full text: Standard radiographs represent the basic tool of hip joint imaging. For detailed analysis of abnormalities related to bone marrow, articular cartilage, labrum and periarticular soft tissues, MRI has become the method of choice. MR arthrography is superior to standard MRI with regard to depicting the intra-articular abnormalities. CT is supporting plain radiographs for accurate depiction of subtle bone details. Ultrasound is commonly used in postoperative hematoma, bursitis, initial diagnosis of cysts and solid soft tissue tumors as well as for image guided injections and biopsies. Bone scintigraphy is suitable for the mapping of multifocal disease, such as osseous metastatic deposits. PET and PET/CT may be able to differentiate malignant neoplasm and infection from other abnormalities. A common disorder often requested for evaluation, is osteoarthritis. MRI is able to depict early degenerative changes which are occult on plain radiographs. CT- or MR arthrography provide a better evaluation of these changes but should only be performed in cases in which conservative surgery is considered to offer a significant clinical improvement for the patient. These cases include cam type femoroacetabular impingement and traumatic chondrolysis. MRI is an imaging technique that allows direct visualization of the bone marrow. Marrow disorders of the hip may induce a variety of imaging findings and frequently are not detected by conventional radiographic techniques until they have reached an advanced clinical stage. The excellent spatial and contrast resolution provided by MRI facilitates early detection and evaluation of various disorders allowing thus prompt treatment. Imaging findings may alter or guide the correct treatment. In addition, the association of marrow changes and pain such as in osteonecrosis and osteoarthritis is clinically relevant. For imaging the bone marrow, we use a combination of pulse sequences, including T1-w spin echo, PD/T2-w turbo spin echo

  1. Influence of the hip flexion angle on isokinetic hip rotator torque and acceleration time of the hip rotator muscles.

    Science.gov (United States)

    Baldon, Rodrigo de M; Furlan, Leonardo; Serrão, Fábio V

    2013-10-01

    The purpose of this study was to verify the influence of the hip flexion angle on isokinetic rotator torque and acceleration times of the hip medial and lateral rotator muscles. Twenty-one healthy women were included in this study. The hip rotator function was evaluated at 3 different hip flexion angles (10°, 40°, and 90°). The results showed that both eccentric and concentric hip lateral rotator torques were greater at 40° of hip flexion when compared with 90°. Moreover, both the eccentric and concentric hip medial rotator torques were greater at 90° of hip flexion than at 40° and 10°, and greater at 40° than at 10°. In addition, both the eccentric and concentric hip medial to lateral rotator torque ratios were greater at 90° of hip flexion than at 40° and 10°, and greater at 40° than at 10°. Finally, the acceleration times of the hip medial rotator muscles were smaller at 90° of hip flexion than at 10° and smaller at 40° than at 10°. The current results highlight the importance of evaluating the hip rotator muscles at different hip flexion angles to comprehensively assess their functions.

  2. Minimum Five-Year Outcomes with Porous Tantalum Acetabular Cup and Augment Construct in Complex Revision Total Hip Arthroplasty.

    Science.gov (United States)

    Jenkins, Derek R; Odland, Andrew N; Sierra, Rafael J; Hanssen, Arlen D; Lewallen, David G

    2017-05-17

    The use of a trabecular metal revision shell with metal augmentation to fill segmental or irregular defects during complex revision hip arthroplasty has been shown to provide good short-term results in prior published series. Longer-term results of the several cup-augment constructs used clinically are not known. The objective of this study was to report, with minimum 5-year radiographic and clinical follow-up, the outcome of these various constructs in revision total hip arthroplasty. Eighty-four patients (85 hips) underwent revision total hip arthroplasty with use of porous tantalum augments between 2000 and 2007 at a single institution and were retrospectively reviewed. Fifty-seven of the patients (58 hips) had clinical and radiographic follow-up at a minimum of 5 years. At the time of revision, the majority of the hips had acetabular defects classified as Paprosky Type 3A (28 of 58, 48%) or Type 3B (22 of 58, 38%). Eleven (19%) of the hips also had preoperative pelvic discontinuity. All hips were assessed clinically at a minimum of 5 years with use of the Mayo hip score. Postoperative radiographs were reviewed for implant stability, the presence and location of radiolucent lines and healing of the discontinuity if present. In 2 (3%) of the 58 hips, the constructs failed because of aseptic loosening of the acetabular component and re-revision was indicated. Six (10%) of the 58 hips demonstrated a radiolucent line between the trabecular metal shell and bone in DeLee and Charnley zone 3. In 1 hip that underwent re-revision and in 5 of the 6 hips with a zone-3 radiolucency, a pelvic discontinuity was present at the time of the index revision. The mean preoperative Mayo hip score was 35.7, which improved to 61.9 at 3 months and was 61.7 at the minimum 5-year follow-up. With failure defined as aseptic loosening requiring repeat revision surgery, this cohort demonstrated 97% survivorship and maintained satisfactory hip function at the minimum 5 years after the index

  3. CURBSIDE CONSULTATION IN HIP ARTHROPLASTY

    Directory of Open Access Journals (Sweden)

    Scott M. Sporer

    2009-03-01

    Full Text Available DESCRIPTION A user friendly reference for decision making in hip arthroplasty designed in a question formed clinical problem scenarios and answers format .The articles composed of the answers, containing current concepts and preferences of experts in primary and revision hip surgery are enhanced by several images, diagrams and references and written in the form of a curbside consultation by Scott M. Sporer, MD. and his collaborators. PURPOSE By this practical reference of hip arthroplasty, Scott M. Sporer, MD. and the contributors have aimed providing the reader practical and clinically relevant information, evidence-based advices, their preferences and opinions containing current concepts for difficult and controversial clinical situations in total hip replacement surgery which are often not addressed clearly in traditional references. FEATURES The book is composed of 9 sections and 49 articles each written by a different expert designed in a question and answers format including several images and diagrams and also essential references at the end of each article. In the first section preoperative questions is subjected. Second section is about preoperative acetabulum questions. Third section is about preoperative femur questions. Fourth section is about intraoperative questions. Intraoperative acetabulum question is subjected in the fifth section and the intraoperative femur questions in the sixth section. The seventh section is about postoperative questions. Eighth and ninth sections are about general questions about failure and failure of acetabulum in turn. AUDIENCE Mainly practicing orthopedic surgeons, fellows and residents who are interested in hip arthroplasty have been targeted but several carefully designed scenarios of controversial and difficult situations surrounding total hip replacement surgery and the current information will also be welcomed by experienced clinicians practicing in hip arthroplasty. ASSESSMENT Scott M. Sporer

  4. Trunnionosis in total hip arthroplasty: a review.

    Science.gov (United States)

    Mistry, Jaydev B; Chughtai, Morad; Elmallah, Randa K; Diedrich, Aloise; Le, Sidney; Thomas, Melbin; Mont, Michael A

    2016-03-01

    Trunnionosis is defined as wear of the femoral head-neck interface and has recently been acknowledged as a growing cause of total hip arthroplasty failure. Some studies have reported that it accounts for up to 3 % of all revisions. The exact cause of trunnionosis is currently unknown; however, postulated etiologies include modular junction wear, corrosion damage, and metal ion release. Additionally, implant design and trunnion geometries may contribute to the progression of component failure. In order to aid in our understanding of this phenomenon, our aim was to present the current literature on (1) the effect of femoral head size on trunnionosis, (2) the effect of trunnion design on trunnionosis, (3) localized biological reactions associated with trunnionosis, and (4) gross trunnion failures. It is hoped that this will encourage further research and interest aimed at minimizing this complication.

  5. Osteochondritis Dissecans of the Hip

    Energy Technology Data Exchange (ETDEWEB)

    Linden, B. [Hoeglands Hospital, Eksjoe (Sweden). Dept. of Orthopedic Surgery; Jonsson, K. [Univ. Hospital, Lund (Sweden). Center for Medical Imaging and Physiology; Redlund-Johnell, I. [Univ. Hospital, Malmoe (Sweden). Dept. of Diagnostic Radiology

    2003-03-01

    Purpose: To investigate the clinical and radiological characteristics of osteochondritis dissecans (OD) of the hip and the outcome of this condition after treatment. Material and Methods: Twelve male and 3 female patients with OD were retrospectively studied. Six patients had a history of Legg-Calve-Perthes disease (LCPD) and among them 2 also had had a trauma to the hip. A further 5 had had trauma and 1 a developmental dislocation of the hip (DDH). The remaining 3 patients had no history of previous hip disease or trauma. All patients were examined with plain radiography, 7 with MR, 3 with CT and 2 with hip arthrography. Results: All OD lesions were detected at plain radiography, and most of them were located near the fovea. At MR the lesions had low signal intensity at T1-weighted sequences, and 6/7 had edema or fluid collection in or adjacent to the lesion on T2-weighted sequences. The early treatment in 7 patients was surgery, 2 had had conservative treatment and 6 no treatment. At follow-up 12 years after radiological diagnosis, 5 patients had hip arthrosis, 4 of whom were treated with arthroplasty. All but 3 had reduced hip rotation and all but 2 (with arthroplasty) had load pain. Three of the patients with earlier surgery had not developed arthrosis. Conclusions: OD lesions are usually well seen with plain radiography. There is a great risk of developing early arthrosis and it seems that early surgery is connected with arthrosis development. Thus only symptomatic treatment is recommended.

  6. Osteochondritis Dissecans of the Hip

    International Nuclear Information System (INIS)

    Linden, B.; Jonsson, K.; Redlund-Johnell, I.

    2003-01-01

    Purpose: To investigate the clinical and radiological characteristics of osteochondritis dissecans (OD) of the hip and the outcome of this condition after treatment. Material and Methods: Twelve male and 3 female patients with OD were retrospectively studied. Six patients had a history of Legg-Calve-Perthes disease (LCPD) and among them 2 also had had a trauma to the hip. A further 5 had had trauma and 1 a developmental dislocation of the hip (DDH). The remaining 3 patients had no history of previous hip disease or trauma. All patients were examined with plain radiography, 7 with MR, 3 with CT and 2 with hip arthrography. Results: All OD lesions were detected at plain radiography, and most of them were located near the fovea. At MR the lesions had low signal intensity at T1-weighted sequences, and 6/7 had edema or fluid collection in or adjacent to the lesion on T2-weighted sequences. The early treatment in 7 patients was surgery, 2 had had conservative treatment and 6 no treatment. At follow-up 12 years after radiological diagnosis, 5 patients had hip arthrosis, 4 of whom were treated with arthroplasty. All but 3 had reduced hip rotation and all but 2 (with arthroplasty) had load pain. Three of the patients with earlier surgery had not developed arthrosis. Conclusions: OD lesions are usually well seen with plain radiography. There is a great risk of developing early arthrosis and it seems that early surgery is connected with arthrosis development. Thus only symptomatic treatment is recommended

  7. Emerging topics on the hip: Ligamentum teres and hip microinstability

    International Nuclear Information System (INIS)

    Cerezal, Luis; Arnaiz, Javier; Canga, Ana; Piedra, Tatiana; Altónaga, José R.; Munafo, Ricardo; Pérez-Carro, Luis

    2012-01-01

    Microinstability and ligament teres lesions are emergent topics on the hip pathology. These entities are an increasingly recognized cause of persistent hip pain and should be considered in the differential diagnosis of the patient with hip pain. Conventional (non-arthrographic) CT and MR have a very limited role in the evaluation of these entities. CTa and MRa have emerged as the modalities of choice for pre-operative imaging of ligamentum teres injuries and microinstability. To date, pre-operative imaging detection of these pathologies is not widespread but with appropriate imaging and a high index of suspicion, preoperative detection should improve. This article discusses current concepts regarding anatomy, biomechanics, clinical findings, diagnosis and treatment of ligament teres lesions and microinstability.

  8. Emerging topics on the hip: ligamentum teres and hip microinstability.

    Science.gov (United States)

    Cerezal, Luis; Arnaiz, Javier; Canga, Ana; Piedra, Tatiana; Altónaga, José R; Munafo, Ricardo; Pérez-Carro, Luis

    2012-12-01

    Microinstability and ligament teres lesions are emergent topics on the hip pathology. These entities are an increasingly recognized cause of persistent hip pain and should be considered in the differential diagnosis of the patient with hip pain. Conventional (non-arthrographic) CT and MR have a very limited role in the evaluation of these entities. CTa and MRa have emerged as the modalities of choice for pre-operative imaging of ligamentum teres injuries and microinstability. To date, pre-operative imaging detection of these pathologies is not widespread but with appropriate imaging and a high index of suspicion, preoperative detection should improve. This article discusses current concepts regarding anatomy, biomechanics, clinical findings, diagnosis and treatment of ligament teres lesions and microinstability. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  9. The impact of proximal femoral morphology on failure strength with a mid-head resection short-stem hip arthroplasty.

    Science.gov (United States)

    Olsen, Michael; Al Saied, Mohamed; Morison, Zachary; Sellan, Michael; Waddell, James P; Schemitsch, Emil H

    2014-12-01

    Mid-head resection short-stem hip arthroplasty is a conservative alternative to conventional total hip replacement and addresses proximal fixation challenges in patients not suitable for hip resurfacing. It is unclear whether proximal femoral morphology impacts the ultimate failure load of mid-head resection implanted femurs, thus the aim of this study was to investigate the effect of native neck-shaft angle (NSA) and coronal implant alignment on proximal femoral strength. In total, 36 synthetic femurs with two different proximal femoral morphologies were utilized in this study. Of them, 18 femurs with a varus NSA of 120° and 18 femurs with a valgus NSA of 135° were each implanted with a mid-head resection prosthesis. Femurs within the two different femoral morphology groups were divided into three equal coronal implant alignment groups: 10° valgus, 10° varus or neutral alignment. Prepared femurs were tested for stiffness and to failure in axial compression. There was no significant difference in stiffness nor failure load between femurs implanted with valgus-, varus- or neutrally aligned implants in femurs with a NSA of 120° (p = 0.396, p = 0.111, respectively). Femurs implanted in valgus orientation were significantly stiffer and failed at significantly higher loads than those implanted in varus alignment in femurs with a NSA of 135° (p = 0.001, p = 0.007, respectively). A mid-head resection short-stem hip arthroplasty seems less sensitive to clinically relevant variations of coronal implant alignment and may be more forgiving upon implantation in some femoral morphologies, however, a relative valgus component alignment is recommended. © IMechE 2014.

  10. Developmental dysplasia of the hip

    Directory of Open Access Journals (Sweden)

    Shahryar Noordin

    2010-10-01

    Full Text Available Developmental dysplasia of the hip (DDH is a spectrum of anatomical abnormalities of the hip joint in which the femoral head has an abnormal relationship with the acetabulum. Most studies report an incidence of 1 to 34 cases per 1,000 live births and differences could be due to different diagnostic methods and timing of evaluation. Risk factors include first born status, female sex, positive family history, breech presentation and oligohydramnios. Clinical presentations of DDH depend on the age of the child. Newborns present with hip instability, infants have limited hip abduction on examination, and older children and adolescents present with limping, joint pain, and/or osteoarthritis. Repeated, careful examination of all infants from birth and throughout the first year of life until the child begins walking is important to prevent late cases. Provocative testing includes the Barlow and Ortolani maneuvers. Other signs, such as shorting of the femur with hips and knees flexed (Galeazzi sign, asymmetry of the thigh or gluteal folds, and discrepancy of leg lengths are potential clues. Treatment depends on age at presentation and outcomes are much better when the child is treated early, particularly during the first six months of life.

  11. Excess mortality following hip fracture

    DEFF Research Database (Denmark)

    Abrahamsen, B; van Staa, T; Ariely, R

    2009-01-01

    Summary This systematic literature review has shown that patients experiencing hip fracture after low-impact trauma are at considerable excess risk for death compared with nonhip fracture/community control populations. The increased mortality risk may persist for several years thereafter, highlig......Summary This systematic literature review has shown that patients experiencing hip fracture after low-impact trauma are at considerable excess risk for death compared with nonhip fracture/community control populations. The increased mortality risk may persist for several years thereafter...... and excess mortality rates for hip fracture. Although a lack of consistent study design precluded any formal meta-analysis or pooled analysis of the data, we have shown that hip fracture is associated with excess mortality (over and above mortality rates in nonhip fracture/community control populations......) during the first year after fracture ranging from 8.4% to 36%. In the identified studies, individuals experienced an increased relative risk for mortality following hip fracture that was at least double that for the age-matched control population, became less pronounced with advancing age, was higher...

  12. Traumatic hip dislocations in children

    International Nuclear Information System (INIS)

    Minhas, M.S.

    2010-01-01

    Objectives: To evaluate clinical features, treatment and relationship to the time period between dislocation, reduction and early complications of traumatic dislocation of hip in children. Methods: Case series conducted at Jinnah Post Graduate Medical Centre Karachi from July 2005 to August 2009. Children with traumatic hip dislocation up to fifteen years of age who presented in last four years were included in this study. Their clinical information, etiology, associated injuries, duration, method of reduction and early complications are evaluated through emergency room proforma and indoor record. Follow up of patient was updated in outpatient department. Results: We had eight patients, six boys and two girls. Youngest 2.4 years and eldest was 12 years with mean age of 6.2 +- 3.8 years. All presented with posterior hip dislocation. Etiology was road traffic accident in two and history of fall in remaining six patients. Average duration of time between dislocation and reduction was 19 hours range 3-72 hours. Dislocated hips were reduced under General Anaesthesia in two patients and under sedation analgesia in six patients. No complications were noted in eight cases with mean 18.75 +- 13.23 months follows up. Conclusion: Traumatic hip dislocation in children is not rare. Slight trauma causes dislocation in younger age and immediate closed reduction and Immobilization reduces complications. (author

  13. Evaluation of the patient with hip pain.

    Science.gov (United States)

    Wilson, John J; Furukawa, Masaru

    2014-01-01

    Hip pain is a common and disabling condition that affects patients of all ages. The differential diagnosis of hip pain is broad, presenting a diagnostic challenge. Patients often express that their hip pain is localized to one of three anatomic regions: the anterior hip and groin, the posterior hip and buttock, or the lateral hip. Anterior hip and groin pain is commonly associated with intra-articular pathology, such as osteoarthritis and hip labral tears. Posterior hip pain is associated with piriformis syndrome, sacroiliac joint dysfunction, lumbar radiculopathy, and less commonly ischiofemoral impingement and vascular claudication. Lateral hip pain occurs with greater trochanteric pain syndrome. Clinical examination tests, although helpful, are not highly sensitive or specific for most diagnoses; however, a rational approach to the hip examination can be used. Radiography should be performed if acute fracture, dislocations, or stress fractures are suspected. Initial plain radiography of the hip should include an anteroposterior view of the pelvis and frog-leg lateral view of the symptomatic hip. Magnetic resonance imaging should be performed if the history and plain radiograph results are not diagnostic. Magnetic resonance imaging is valuable for the detection of occult traumatic fractures, stress fractures, and osteonecrosis of the femoral head. Magnetic resonance arthrography is the diagnostic test of choice for labral tears.

  14. Developmental hip dysplasia in adolescence

    Directory of Open Access Journals (Sweden)

    Vukašinović Zoran

    2009-01-01

    Full Text Available The authors define adolescence and developmental dysplasia of the hip (DDH. Special attention is paid to pathological findings characteristic of DDH in adolescence (unrecognized and untreated DDH; treated DDH, but non-terminated treatment; DDH diagnosed with delay, inadequately treated, with complications. The authors emphasise that DDH treatment has to be successfully terminated well before the adolescence; possibilities are explained on management modes at the time of adolescence, and possible persons guilty for the persistence of later hip problems are indicated. Based on the authors' experience and having in mind all surgical possibilities for the treatment (pelvic osteotomies, femoral osteotomies, trochanteroplasties, leg length equalization procedures the authors propose treatment protocols. The intention is to provide better treatment results and to prevent secondary hip arthrosis. Furthermore, how to improve the struggle against DDH is suggested.

  15. MRI of the hip joint

    International Nuclear Information System (INIS)

    Czerny, C.; Noebauer-Huhmann, I.M.; Imhof, H.

    2005-01-01

    Magnetic resonance imaging (MRI) is performed to diagnose many pathologic conditions affecting the hip joint. Either conventional MRI (without contrast enhancement of the joint cavity) or MR arthrography is used to detect and most accurately differentiate hip joint pathologies. Conventional MRI is performed in cases of bone marrow edema, necrosis, arthrosis and especially the so-called ''activated arthrosis'', as well as in inflammatory and tumorous entities. MR arthography, which has only recently become available for use, is excellently suited for diagnosing lesions of the acetabular labrum, cartilage lesions, and free articular bodies. This article provides an overview about MRI characteristics and their accuracy of hip joint diseases and the impact on the therapeutic procedure. (orig.)

  16. Properties of Rose Hip Marmalades

    Directory of Open Access Journals (Sweden)

    Oktay Yildiz

    2012-01-01

    Full Text Available Rose hip, also known as wild rose, is a summer fruit. The aim of this research is to present physical, chemical, rheological, sensory and antioxidant properties of rose hip marmalades. Rose hips cultivated in Turkey are processed into pulp and then marmalade is made by using vacuum evaporator or classical method. For the purposes of this investigation, marmalades produced on a factory scale using two methods were compared to commercial marmalades purchased on market. The marmalades exhibited high levels of antioxidant activity as well as total phenolic content. The consistency indices for the marmalades were determined to be between 64.2 and 321 Pa·s^n. Colour parameters, namely L, a, b, were measured and correlations between the examined parameters were calculated.

  17. Cementless Hydroxyapatite Coated Hip Prostheses

    Directory of Open Access Journals (Sweden)

    Antonio Herrera

    2015-01-01

    Full Text Available More than twenty years ago, hydroxyapatite (HA, calcium phosphate ceramics, was introduced as a coating for cementless hip prostheses. The choice of this ceramic is due to its composition being similar to organic apatite bone crystals. This ceramic is biocompatible, bioactive, and osteoconductive. These qualities facilitate the primary stability and osseointegration of implants. Our surgical experience includes the implantation of more than 4,000 cementless hydroxyapatite coated hip prostheses since 1990. The models implanted are coated with HA in the acetabulum and in the metaphyseal area of the stem. The results corresponding to survival and stability of implants were very satisfactory in the long-term. From our experience, HA-coated hip implants are a reliable alternative which can achieve long term survival, provided that certain requirements are met: good design selection, sound choice of bearing surfaces based on patient life expectancy, meticulous surgical technique, and indications based on adequate bone quality.

  18. Cementless Hydroxyapatite Coated Hip Prostheses

    Science.gov (United States)

    Herrera, Antonio; Mateo, Jesús; Gil-Albarova, Jorge; Lobo-Escolar, Antonio; Ibarz, Elena; Gabarre, Sergio; Más, Yolanda

    2015-01-01

    More than twenty years ago, hydroxyapatite (HA), calcium phosphate ceramics, was introduced as a coating for cementless hip prostheses. The choice of this ceramic is due to its composition being similar to organic apatite bone crystals. This ceramic is biocompatible, bioactive, and osteoconductive. These qualities facilitate the primary stability and osseointegration of implants. Our surgical experience includes the implantation of more than 4,000 cementless hydroxyapatite coated hip prostheses since 1990. The models implanted are coated with HA in the acetabulum and in the metaphyseal area of the stem. The results corresponding to survival and stability of implants were very satisfactory in the long-term. From our experience, HA-coated hip implants are a reliable alternative which can achieve long term survival, provided that certain requirements are met: good design selection, sound choice of bearing surfaces based on patient life expectancy, meticulous surgical technique, and indications based on adequate bone quality. PMID:25802848

  19. Early results with the thrust plate prosthesis in young patients with osteoarthritis of the hip.

    Science.gov (United States)

    Sharma, Sanjeev; Verma, Gopalkrishna; Draviraj, Kingsley Paul; Bhamra, Manjit

    2005-04-01

    The purpose of this study was to evaluate the results of the Thrust Plate Prosthesis as a treatment option for osteoarthritis of the hip in young patients. Of the fifty patients (63 hips) reviewed, 31 (62%) were males and 19 (38%) females. Pre-operative diagnosis included primary osteoarthritis (23), developmental dysplasia (8), avascular necrosis (7), Perthes (4), post-traumatic arthritis (3), rheumatoid arthritis (2), ankylosing spondylitis (1), psoriatic arthropathy (1) and slipped upper femoral epiphysis (1). All components were implanted uncemented with metal-on-metal articulation. The average follow-up was 4.04 years (range 12 months-8.5 years). The mean age of the patients was 42.3 years (range 21-57 years). The mean pre-operative Harris Hip Score was 41.9 (range 12-89) and at final follow-up 89.91 (range 41-100). In 25 hips with > or = 5 yr follow-up, the average HHS at final follow-up was 84.5 (range 50-100). Complications included dislocation (2), transient sciatic nerve palsy (1), discomfort from lateral strap (2), implantation of wrong femoral head (1), revision (3 = 4.76%) and implant loosening (4) (6.35%). The thrust plate prosthesis is a useful alternative in young patients with hip arthritis and the results are comparable with other uncemented hip replacements. The added advantage is preservation of the proximal femoral bone stock, which can prove useful in future revisions.

  20. Deciding to have knee or hip replacement

    Science.gov (United States)

    ... 000368.htm Deciding to have knee or hip replacement To use the sharing features on this page, ... a decision. Who Benefits From Knee or hip Replacement Surgery? The most common reason to have a ...

  1. Risks of hip and knee replacement

    Science.gov (United States)

    ... lose blood during and after hip or knee replacement surgery. Some people need a blood transfusion during ... higher during and soon after hip or knee replacement surgery. Sitting or lying down for long periods ...

  2. The efficacy of autologous platelet rich plasma combined with ablative carbon dioxide fractional resurfacing for acne scars: a simultaneous split-face trial.

    Science.gov (United States)

    Lee, Jin Woong; Kim, Beom Joon; Kim, Myeung Nam; Mun, Seog Kyun

    2011-07-01

    Ablative carbon dioxide (CO(2) ) fractional resurfacing is a promising therapeutic intervention for the treatment of acne scars, although this technique is associated with prolonged surgical site erythema and edema, which may affect the daily lives of patients. Autologous platelet-rich plasma (PRP) is known to enhance wound healing and has applications in many areas of medicine. To evaluate the synergistic effects of autologous PRP with CO(2) fractional resurfacing for acne scars. A split-face trial was conducted in 14 Korean participants with acne scars. All participants received one session of ablative CO(2) fractional resurfacing. Immediately after resurfacing, facial halves were randomly assigned to receive treatment with autologous PRP injections on one side (experimental side) and normal saline injections on the other side (control side). The participants were monitored for degree of recovery and resurfacing-associated adverse events, including prolonged erythema, edema, and other effects on days 0, 2, 4, 6, 8, 15, and 30. The intensity of erythema was objectively measured using a chromometer at the same time intervals. After one additional treatment session using the same protocol, two independent dermatologists evaluated clinical improvement using a quartile grading scale. All participants completed the study. Erythema on the experimental side improved faster than on the control side and was significantly less at day 4 (p=.01). This difference was confirmed using a chromometer (p=.049). Total duration of erythema was an average of 10.4±2.7 days on the control side and 8.6±2.0 days on the experimental side (p=.047). Edema also improved faster on the experimental side than on the control side. The total duration of edema was an average of 7.1±1.5 days on the control side and 6.1±1.1 days on the experimental side (p=.04). Participants were also assessed for duration of post-treatment crusting, with a mean of 6.8±1.0 days on the control side and 5.9±1

  3. Computed tomography in abnormalities of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Visser, J.D.; Jonkers, A.; Klasen, H.J. (Rijksuniversiteit Groningen (Netherlands). Academisch Ziekenhuis); Hillen, B. (Rijksuniversiteit Groningen (Netherlands). Lab. voor Anatomie en Embryologie)

    1982-06-26

    The value of computed tomography in the assessment of abnormalities of the hip is demonstrated with the aid of an anatomical preparation and in patients with, respectively, congenital dislocation of a hip, dislocation of the hip in spina bifida, an acetabular fracture and a Ewing tumour. The anteversion of the acetabulum and femur and the instability index of the hip joint can be measured by means of computed tomography.

  4. Ultrasonography of the hip and lower extremity.

    Science.gov (United States)

    Malanga, Gerard A; Dentico, Richard; Halperin, Jonathan S

    2010-08-01

    Musculoskeletal ultrasonographic evaluation of the proximal lower limb includes the evaluation of the soft tissue structures, including tendons, ligaments, or muscles, and the bony structures of this region, include the hip, pubic symphysis, and sacroiliac joints. The evaluation of the hip or proximal lower limb region can be performed in an efficient and systematic manner. Ultrasonography of the lateral hip, intra-articular hip, medial thigh, and posterior thigh are discussed in the article. Copyright 2010 Elsevier Inc. All rights reserved.

  5. Hip Dislocation or Subluxation After Hip Arthroscopy: A Systematic Review.

    Science.gov (United States)

    Duplantier, Neil L; McCulloch, Patrick C; Nho, Shane J; Mather, Richard C; Lewis, Brian D; Harris, Joshua D

    2016-07-01

    To determine patient- and surgery-specific characteristics of patients sustaining postarthroscopic hip dislocation or subluxation. A systematic review of multiple medical databases was registered with PROSPERO and performed using Preferred Reporting Items for Systemic Reviews and Meta-Analysis guidelines. Level I to IV clinical outcome studies reporting the presence of hip dislocation or subluxation after hip arthroscopy were eligible. Length of follow-up was not an exclusion criterion. All patient- and surgery-specific variables were extracted from each, specifically evaluating osseous morphology and resection details; labral, iliopsoas, ligamentum teres, and capsular management; generalized ligamentous laxity; instability direction and mechanism; management; and outcome. Study authors were individually contacted to assess most recent outcome. Ten articles with 11 patients were analyzed (mean patient age: 36.6 ± 12.3 years). There were 9 hip dislocations and 2 subluxations. Mean time between surgery and dislocation was 3.2 ± 4.0 months (range: recovery room to 14 months). Anterior was the most frequent dislocation direction (8 cases). Acetabular undercoverage (preoperative dysplasia or iatrogenic rim over-resection) was observed in 5 cases. Labral debridement was performed in 5 cases, iliopsoas tenotomy in 3 cases, and ligamentum teres debridement in 1 case. A "T" capsulotomy was created in 1 case (isolated interportal in other 10 cases). Capsular closure was performed in 2 cases (both interportal). Generalized ligamentous laxity was diagnosed in 1 case. A combination of external rotation and extension was observed in 5 of the 6 cases reporting the mechanism of anterior dislocation. Four cases were successfully treated with closed reduction; 4 required total hip arthroplasty; and 3 required revision capsulorrhaphy. Postarthroscopic hip instability was observed in patients with acetabular undercoverage (including iatrogenic resection), labral debridement

  6. An unusual presentation of catastrophic failure of hip arthroplasty with a thigh mass

    Directory of Open Access Journals (Sweden)

    Florian Dibra, MD

    2016-06-01

    Full Text Available In the advent of increasing demand for total hip arthroplasty, surveillance of these patients is imperative to identify potential complications requiring revision surgery. This is especially important in the young population, as revision is usually necessary during their lifetime. We present a case of a young female patient with a history of total hip arthroplasty 17 years prior, who presented with left hip pain and anterior thigh mass. The prosthetic hip had progressed to catastrophic failure with the cobalt-chrome femoral head having eroded through the polyethylene and acetabular socket. This was associated with significant metal debris and large fluid collection in the thigh. The patient required complex revision surgery but could have had a much lesser procedure with earlier intervention.

  7. Treatment of tuberculosis of the hip.

    African Journals Online (AJOL)

    Key Words: tuberculosis, hip, treatment. Between September 1986 and December 1993,. 57 patients were seen with tuberculosis of the hip at Kenyatta National Hospital. The diagnosis was proven by ... LA 7cetahtiltdm and femoral head with early subluxation. FIG 2 Radiograph showing stabltciation of a ttihercltlolu hip.

  8. Hip-Hop and the Academic Canon

    Science.gov (United States)

    Abe, Daudi

    2009-01-01

    Over the last 30 years, the hip-hop movement has risen from the margins to become the preeminent force in US popular culture. In more recent times academics have begun to harness the power of hip-hop culture and use it as a means of infusing transformative knowledge into the mainstream academic discourse. On many college campuses, hip-hop's…

  9. Clicky hip alone is not a true risk factor for developmental dysplasia of the hip.

    Science.gov (United States)

    Nie, K; Rymaruk, S; Paton, R W

    2017-11-01

    A clicky hip is a common referral for clinical and sonographic screening for developmental dysplasia of the hip (DDH). There is controversy regarding whether it represents a true risk factor for pathological DDH. Therefore a 20-year prospective, longitudinal, observational study was undertaken to assess the relationship between the presence of a neonatal clicky hip and pathological DDH. A total of 362 infants from 1997 to 2016 were referred with clicky hips to our 'one-stop' paediatric hip screening clinic. Hips were assessed clinically for instability and by ultrasound imaging using a simplified Graf/Harcke classification. Dislocated or dislocatable hips were classified as Graf Type IV hips. The mean age at presentation was 13.8 weeks (12.8 to 14.7). In all 351 out of 362 children (97.0%) had Graf Type I hips (normal) that required no treatment. Nine children (2.5%) had Graf Type II hips but all resolved to Graf Type I hips on follow-up scans. One child (0.3%) had Graf Type III hip dysplasia and one child (0.3%) had an irreducible hip dislocation. The two pathological hips were associated with unilateral limited hip abduction. Mean referrals increased from 12.9 to 23.3 each year (p = 0.002) from the first decade of the study to the second, driven by increasing primary care referrals (5.5 versus 16.7 per year, p hips required no treatment other than reassurance to parents. Clicky hips with a normal hip examination should be considered a variant of normal childhood and not a risk factor for DDH. However, an abnormal hip examination including unilateral limited hip abduction should prompt urgent further investigations. Cite this article: Bone Joint J 2017;99-B:1533-6. ©2017 The British Editorial Society of Bone & Joint Surgery.

  10. Hip Hip Hurrah! Hip size inversely related to heart disease and total mortality

    DEFF Research Database (Denmark)

    Heitmann, B L; Lissner, L

    2011-01-01

    obesity and/or waist circumference. These studies have been remarkable in terms of their consistency, and in the unexpected finding of an adverse effect of small hip size, after statistically correcting for differences in general and abdominal size. The hazard related to a small hip size may be stronger...... for women than men, but is evident in both genders. In this 'viewpoint', we wish to draw attention to the emerging body of evidence and to encourage researchers to continue collecting measures of lower body size in their surveys....

  11. Assessment of total hip arthroplasty as a predisposing factor for ischiofemoral impingement

    International Nuclear Information System (INIS)

    Oliveira, Adriana L.; Azevedo, Debora C.; Eajazi, Alireza; Palmer, William E.; Bredella, Miriam A.; Kwon, Young-Min; Torriani, Martin

    2015-01-01

    To examine the effect of total hip arthroplasty (THA) on ischiofemoral (IF) and quadratus femoris (QF) spaces with the hypothesis that THA does not affect ischiofemoral relationships. The study was IRB approved and complied with HIPAA guidelines. We identified consecutive MR examinations (pelvis and/or hip) obtained at our institution in adults (≥18 years old) screened for THA-related complications. Native hips from the same individuals served as controls. We collected medical record data including age, gender, surgical history, and THA designs. Two radiologists independently measured the IF-RAD and IF-MRI (IF space on radiographs and MR imaging, respectively) and QF space (on MR imaging). Groups were compared using ANCOVA controlled for gender. The study group comprised 250 hips (132 subjects; 162 post-THA and 88 native hips). Subjects were aged 59 ± 10 years, with 66 males and 66 females. Comparison of IF-MRI and QF spaces between native and post-THA hips showed no differences (P > 0.12) and IF-RAD was higher in post-THA subjects (P = 0.01). No differences in the IF-MRI and QF spaces were present between native hips and different THA designs (P > 0.4). IF-RAD of metal-on-metal THA was higher than that of native hips (P = 0.01) and trended higher than ceramic-on-polyethylene THA (P = 0.08), with the remaining comparisons showing no significant differences (P > 0.4). Radiographic- and MRI-based measures in patients with standard THA do not show narrowing of IF and QF spaces. (orig.)

  12. Assessment of total hip arthroplasty as a predisposing factor for ischiofemoral impingement

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Adriana L.; Azevedo, Debora C.; Eajazi, Alireza; Palmer, William E.; Bredella, Miriam A. [Massachusetts General Hospital and Harvard Medical School, Division of Musculoskeletal Imaging and Intervention, Boston, MA (United States); Kwon, Young-Min [Massachusetts General Hospital and Harvard Medical School, Department of Orthopedics, Boston, MA (United States); Torriani, Martin [Massachusetts General Hospital and Harvard Medical School, Division of Musculoskeletal Imaging and Intervention, Boston, MA (United States); Massachusetts General Hospital, Division of Musculoskeletal Imaging and Intervention Department of Radiology, Boston, MA (United States)

    2015-12-15

    To examine the effect of total hip arthroplasty (THA) on ischiofemoral (IF) and quadratus femoris (QF) spaces with the hypothesis that THA does not affect ischiofemoral relationships. The study was IRB approved and complied with HIPAA guidelines. We identified consecutive MR examinations (pelvis and/or hip) obtained at our institution in adults (≥18 years old) screened for THA-related complications. Native hips from the same individuals served as controls. We collected medical record data including age, gender, surgical history, and THA designs. Two radiologists independently measured the IF-RAD and IF-MRI (IF space on radiographs and MR imaging, respectively) and QF space (on MR imaging). Groups were compared using ANCOVA controlled for gender. The study group comprised 250 hips (132 subjects; 162 post-THA and 88 native hips). Subjects were aged 59 ± 10 years, with 66 males and 66 females. Comparison of IF-MRI and QF spaces between native and post-THA hips showed no differences (P > 0.12) and IF-RAD was higher in post-THA subjects (P = 0.01). No differences in the IF-MRI and QF spaces were present between native hips and different THA designs (P > 0.4). IF-RAD of metal-on-metal THA was higher than that of native hips (P = 0.01) and trended higher than ceramic-on-polyethylene THA (P = 0.08), with the remaining comparisons showing no significant differences (P > 0.4). Radiographic- and MRI-based measures in patients with standard THA do not show narrowing of IF and QF spaces. (orig.)

  13. Hip-Hop Pop Art

    Science.gov (United States)

    Talley, Clarence, Sr.

    2011-01-01

    Art has a way of helping students better understand and appreciate the world around them, particularly the things that are most important to them. Hip hop is one of those generational genres that capture the attention of young students like few other things do. Drawing on this genre to get students to create art is an excellent way to demonstrate…

  14. X-Ray Exam: Hip

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Hip KidsHealth / For Parents / X-Ray Exam: ... darker. An X-ray technician takes the X-rays. An X-ray technician in the radiology department of a ...

  15. Reverse hybrid total hip arthroplasty

    DEFF Research Database (Denmark)

    Wangen, Helge; Havelin, Leif I.; Fenstad, Anne M

    2017-01-01

    . Patients and methods - From the NARA, we extracted data on reverse hybrid THAs from January 1, 2000 until December 31, 2013. 38,415 such hips were studied and compared with cemented THAs. The Kaplan-Meier method and Cox regression analyses were used to estimate the prosthesis survival and the relative risk...

  16. Imaging of hip joint arthroplasty

    International Nuclear Information System (INIS)

    Mayerhoefer, M.E.; Fruehwald-Pallamar, J.; Czerny, C.

    2009-01-01

    The hip joint is the largest joint in the human body and consequently, its evaluation by diagnostic imaging is highly important. This includes imaging of hip joint arthroplasty, which is used to avoid joint immobility following a wide spectrum of diseases, such as end-stage degenerative disease, avascular necrosis of the femoral head or post-traumatic fractures. Conventional radiography is still the standard imaging modality for the evaluation of hip arthroplasty both directly following surgery and for periodical follow-up. In the majority of cases conventional radiography enables adequate assessment of early and late complications that can arise following hip arthroplasty, such as loosening, prosthetic or periprosthetic fracture, luxation, infection and soft tissue calcification. If the diagnosis cannot be established by means of radiography, advanced imaging methods such as computed tomography (CT) and magnetic resonance imaging (MRI), with or without injection of contrast media, may provide additional information. This is particularly true for the depiction of inflammatory processes. Regardless of the imaging modality used patients' clinical symptoms must also be taken into account in order to establish the correct diagnosis. (orig.) [de

  17. HIP IMPLANT ANALYSIS WITH CATIA

    Directory of Open Access Journals (Sweden)

    Florin CIOFU

    2017-12-01

    Full Text Available CATIA V5R16 is a product of Dassault Systemes, one of the most widely used CAD/CAM/ CAE systems worldwide, with applications in various fields, from the automotive, aerospace, automotive and medical industries. The paper aims to improve the technical, technological and medical knowledge related to the activity of the hip prosthesis.

  18. Use of medical tourism for hip and knee surgery in osteoarthritis: a qualitative examination of distinctive attitudinal characteristics among Canadian patients.

    Science.gov (United States)

    Crooks, Valorie A; Cameron, Keri; Chouinard, Vera; Johnston, Rory; Snyder, Jeremy; Casey, Victoria

    2012-11-21

    Medical tourism is the term that describes patients' international travel with the intention of seeking medical treatment. Some medical tourists go abroad for orthopaedic surgeries, including hip and knee resurfacing and replacement. In this article we examine the findings of interviews with Canadian medical tourists who went abroad for such surgeries to determine what is distinctive about their attitudes when compared to existing qualitative research findings about patients' decision-making in and experiences of these same procedures in their home countries. Fourteen Canadian medical tourists participated in semi-structured phone interviews, all of whom had gone abroad for hip or knee surgery to treat osteoarthritis. Transcripts were coded and thematically analysed, which involved comparing emerging findings to those in the existing qualitative literature on hip and knee surgery. Three distinctive attitudinal characteristics among participants were identified when interview themes were compared to findings in the existing qualitative research on hip and knee surgery in osteoarthritis. These attitudinal characteristics were that the medical tourists we spoke with were: (1) comfortable health-related decision-makers; (2) unwavering in their views about procedure necessity and urgency; and (3) firm in their desires to maintain active lives. Compared to other patients reported on in the existing qualitative hip and knee surgery literature, medical tourists are less likely to question their need for surgery and are particularly active in their pursuit of surgical intervention. They are also comfortable with taking control of health-related decisions. Future research is needed to identify motivators behind patients' pursuit of care abroad, determine if the attitudinal characteristics identified here hold true for other patient groups, and ascertain the impact of these attitudinal characteristics on surgical outcomes. Arthritis care providers can use the attitudinal

  19. Use of medical tourism for hip and knee surgery in osteoarthritis: a qualitative examination of distinctive attitudinal characteristics among Canadian patients

    Directory of Open Access Journals (Sweden)

    Crooks Valorie A

    2012-11-01

    Full Text Available Abstract Background Medical tourism is the term that describes patients’ international travel with the intention of seeking medical treatment. Some medical tourists go abroad for orthopaedic surgeries, including hip and knee resurfacing and replacement. In this article we examine the findings of interviews with Canadian medical tourists who went abroad for such surgeries to determine what is distinctive about their attitudes when compared to existing qualitative research findings about patients’ decision-making in and experiences of these same procedures in their home countries. Methods Fourteen Canadian medical tourists participated in semi-structured phone interviews, all of whom had gone abroad for hip or knee surgery to treat osteoarthritis. Transcripts were coded and thematically analysed, which involved comparing emerging findings to those in the existing qualitative literature on hip and knee surgery. Results Three distinctive attitudinal characteristics among participants were identified when interview themes were compared to findings in the existing qualitative research on hip and knee surgery in osteoarthritis. These attitudinal characteristics were that the medical tourists we spoke with were: (1 comfortable health-related decision-makers; (2 unwavering in their views about procedure necessity and urgency; and (3 firm in their desires to maintain active lives. Conclusions Compared to other patients reported on in the existing qualitative hip and knee surgery literature, medical tourists are less likely to question their need for surgery and are particularly active in their pursuit of surgical intervention. They are also comfortable with taking control of health-related decisions. Future research is needed to identify motivators behind patients’ pursuit of care abroad, determine if the attitudinal characteristics identified here hold true for other patient groups, and ascertain the impact of these attitudinal characteristics on

  20. Importance of preclinical evaluation of wear in hip implant designs using simulator machines

    Directory of Open Access Journals (Sweden)

    Rafael Mello Trommer

    Full Text Available ABSTRACT Total hip arthroplasty (THA is a surgical procedure that involves the replacement of the damaged joint of the hip by an artificial device. Despite the recognized clinical success of hip implants, wear of the articulating surfaces remains as one of the critical issues influencing performance. Common material combinations used in hip designs comprise metal-on-polymer (MoP, ceramic-on-polymer (CoP, metal-on-metal (MoM, and ceramic-on-ceramic (CoC. However, when the design of the hip implant is concerned besides the materials used, several parameters can influence its wear performance. In this scenario, where the safety and efficacy for the patient are the main issues, it is fundamental to evaluate and predict the wear rate of the hip implant design before its use in THA. This is one of the issues that should be taken into account in the preclinical evaluation step of the product, in which simulated laboratory tests are necessary. However, it is fundamental that the applied motions and loads can reproduce the wear mechanisms physiologically observed in the patient. To replicate the in vivo angular displacements and loadings, special machines known as joint simulators are employed. This article focuses on the main characteristics related to the wear simulation of hip implants using mechanical simulators, giving information to surgeons, researchers, regulatory bodies, etc., about the importance of preclinical wear evaluation. A critical analysis is performed on the differences in the principles of operation of simulators and their effects on the final results, and about future trends in wear simulation.

  1. [Atraumatic hip pain in young adults].

    Science.gov (United States)

    González Murillo, M; Turcu, V; De Nicolás Navas, M B; Yeguas Bermejo, A

    2016-01-01

    Hip pain in the young adult is a disabling pathophysiological process may be related to multiple etiologies. The process must be determined in order to make a diagnosis and follow-up treatment. The case is presented of a 29 year old woman with anemia, atraumatic hip pain on the right side, and a limp of one month onset. The differential diagnosis includes infectious, rheumatological, tumor, avascular necrosis of hip, hip impingement, hip dysplasia, osteoarthritis and other syndromes. Copyright © 2014 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España, S.L.U. All rights reserved.

  2. In Vivo Damage of the Head-Neck Junction in Hard-on-Hard Total Hip Replacements: Effect of Femoral Head Size, Metal Combination, and 12/14 Taper Design

    Directory of Open Access Journals (Sweden)

    Massimiliano Baleani

    2017-07-01

    Full Text Available Recently, concerns have been raised about the potential effect of head-neck junction damage products at the local and systemic levels. Factors that may affect this damage process have not been fully established yet. This study investigated the possible correlations among head-neck junction damage level, implant design, material combination, and patient characteristics. Head-neck junctions of 148 retrieved implants were analysed, including both ceramic-on-ceramic (N = 61 and metal-on-metal (N = 87 bearings. In all cases, the male taper was made of titanium alloy. Damage was evaluated using a four-point scoring system based on damage morphology and extension. Patient age at implantation, implantation time, damage risk factor, and serum ion concentration were considered as independent potential predicting variables. The damage risk factor summarises head-neck design characteristics and junction loading condition. Junction damage correlated with both implantation time and damage factor risk when the head was made of ceramic. A poor correlation was found when the head was made of cobalt alloy. The fretting-corrosion phenomenon seemed mainly mechanically regulated, at least when cobalt alloy components were not involved. When a component was made of cobalt alloy, the role of chemical phenomena increased, likely becoming, over implantation time, the damage driving phenomena of highly stressed junctions.

  3. Evolution of the hip and pelvis.

    Science.gov (United States)

    Hogervorst, Tom; Bouma, Heinse W; de Vos, John

    2009-08-01

    Man's evolution features two unique developments: growing a huge brain and upright gait. Their combination makes the pelvis the most defining skeletal element to read human evolution. Recent revival in joint preserving hip surgery have brought to attention morphological variations of the human hip that appear similar to hips of extant mammals. In man, such variations can produce hip osteoarthrosis through motion. We reviewed the evolution of the hip and pelvis with special interest in morphology that can lead to motion induced osteoarthrosis in man. The combination of giving birth to big brained babies and walking upright has produced marked differences between the sexes in pelvis and hip morphology, each having their characteristic mode of hip impingement and osteoarthrosis.

  4. Hip Imaging in Athletes: Sports Imaging Series.

    Science.gov (United States)

    Agten, Christoph A; Sutter, Reto; Buck, Florian M; Pfirrmann, Christian W A

    2016-08-01

    Hip or groin pain in athletes is common and clinical presentation is often nonspecific. Imaging is a very important diagnostic step in the work-up of athletes with hip pain. This review article provides an overview on hip biomechanics and discusses strategies for hip imaging modalities such as radiography, ultrasonography, computed tomography, and magnetic resonance (MR) imaging (MR arthrography and traction MR arthrography). The authors explain current concepts of femoroacetabular impingement and the problem of high prevalence of cam- and pincer-type morphology in asymptomatic persons. With the main focus on MR imaging, the authors present abnormalities of the hip joint and the surrounding soft tissues that can occur in athletes: intraarticular and extraarticular hip impingement syndromes, labral and cartilage disease, microinstability of the hip, myotendinous injuries, and athletic pubalgia. (©) RSNA, 2016.

  5. Combination of microneedle radiofrequency (RF), fractional RF skin resurfacing and multi-source non-ablative skin tightening for minimal-downtime, full-face skin rejuvenation.

    Science.gov (United States)

    Kaplan, Haim; Kaplan, Lilach

    2016-12-01

    In the recent years, there is a growth in demand for radiofrequency (RF)-based procedures to improve skin texture, laxity and contour. The new generation of systems allow non-invasive and fractional resurfacing treatments on one platform. The aim of this study was to evaluate the safety and efficacy of a new treatment protocol using a multisource RF, combining 3 different modalities in each patient: [1] non-ablative RF skin tightening, [2] fractional skin resurfacing, and [3] microneedling RF for non-ablative coagulation and collagen remodelling. 14 subjects were enrolled in this study using EndyMed PRO ™ platform. Each patient had 8 non-ablative treatments and 4 fractional treatments (fractional skin resurfacing and Intensif). The global aesthetic score was used to evaluate improvement. All patients had improvement in skin appearance. About 43% had excellent or very good improvement above 50%, 18% had good improvement between 25 and 50%, and the rest 39% had a mild improvement of < 25%. Downtime was minimal and no adverse effect was reported. Our data show significant improvement of skin texture, skin laxity and wrinkle reduction achieved using RF treatment platform.

  6. Hip fractures. Epidemiology, risk factors, falls, energy absorption, hip protectors, and prevention

    DEFF Research Database (Denmark)

    Lauritzen, J B

    1997-01-01

    have a high risk of hip fracture (annual rate of 5-6%), and the incidence of falls is about 1,500 falls/1,000 persons/year. Most hip fractures are a result of a direct trauma against the hip. The incidence of falls on the hip among nursing home residents is about 290 falls/1,000 persons/year and about......%, corresponding to 9 out of 247 residents saved from sustaining a hip fracture. The review points to the essentials of the development of hip fracture, which constitutes; risk of fall, type of fall, type of impact, energy absorption, and lastly bone strength, which is the ultimate and last permissive factor......The present review summarizes the pathogenic mechanisms leading to hip fracture based on epidemiological, experimental, and controlled studies. The estimated lifetime risk of hip fracture is about 14% in postmenopausal women and 6% in men. The incidence of hip fractures increases exponentially...

  7. Hip Strength Testing of Soccer Players With Long-Standing Hip and Groin Pain

    DEFF Research Database (Denmark)

    Rafn, Bolette S; Tang, Lars; Nielsen, Peter Martin

    2016-01-01

    OBJECTIVE: To investigate whether self-reported pain during hip strength testing correlates to a large degree with hip muscle strength in soccer players with long-standing unilateral hip and groin pain. DESIGN: Cross-sectional study. SETTING: Clinical assessments at Sports Orthopaedic Research...... Center-Copenhagen (SORC-C), Arthroscopic Centre Amager, Copenhagen University Hospital, Denmark. PARTICIPANTS: Twenty-four male soccer players with unilateral long-standing hip and groin pain. INTERVENTIONS: The soccer players performed 5 reliable hip muscle strength tests (isometric hip flexion......, adduction, abduction, isometric hip flexion-modified Thomas test, and eccentric hip adduction). MAIN OUTCOME MEASURES: Muscle strength was measured with a hand-held dynamometer, and the players rated the pain during testing on a numerical rating scale (0-10). RESULTS: In 4 tests (isometric hip adduction...

  8. Rose hip (Rosa canina L.) oil obtained from waste hip seeds by different extraction methods.

    Science.gov (United States)

    Szentmihályi, Klára; Vinkler, Péter; Lakatos, Béla; Illés, Vendel; Then, Mária

    2002-04-01

    From the rose hip seed, which is generally a waste material, valuable oil can be obtained for medicinal use. Various extraction methods have been compared: traditional solvent extraction with ultrasound-, microwave-, sub- and supercritical fluid extraction (SFE). Unsaturated fatty acid (UFA: oleic-, linoleic- and linolenic acid; 16.25-22.11%, 35.94-54.75%, 20.29-26.48%) and polyunsaturated fatty acid (PUFA:linoleic- and linolenic acid) content were over 90% and 60% in the recovered oils. The oils contained different amounts of metals. The concentration of some metals, particularly iron in microwave oil (27.11 microg g(-1)) is undesirable from the aspect of stability. By traditional solvent extraction, oil was obtained in 4.85 wt/wt%. Subcritical FE appeared to be the best method for the recovery of rose hip oil with highest oil yield (6.68 wt/wt%), carotene- (145.3 microg g(-1)) and linoleic acid content (54.75%). Supercritical FE without organic solvent is suitable for mild recovery of oil. The oil was rich in UFA and PUFA (92.7% and 76.25%) and contained the lowest amount of carotene and pheophytin (36.3 and 45.8 microg g(-1)). Oil yield in most new extraction methods (microwave extraction, super- and subcritical FE) was higher than in the case of traditional Soxhlet extraction. The main benefit of supercritical FE with CO2 is the solvent free oil while in the case of other extractions evaporation of the solvent is needed. Although the content of bioactive compounds in oils was different, all oils may be appropriate for medicinal use.

  9. EXPERIMENTAL RESEARCH OF REGENERATIVE FEATURES IN BONE TISSUES AROUND IMPLANTS AFTER ONE-STAGE BILATERAL TOTAL HIP REPLACEMENT

    Directory of Open Access Journals (Sweden)

    V. M. Mashkov

    2012-01-01

    Full Text Available Objective: to research the specific features of regenerative processes of bone tissue around implants after one-stage bilateral total hip replacement in experiment. Material and methods: 27 total hip replacement operations have been performed in 18 rabbits of breed "chinchilla" to which bipolar femoral endoprosthesis made of titanic alloy PT-38, one type-size, with friction pair metal-on-metal and neck-shaft angle 165 degrees have been implanted: total unilateral hip replacement operations have been performed in 9 animals (control group, one-stage bilateral total hip replacement operations have been performed in 9 animals (experimental group. During research they have been on radiological and clinical checking-up. After the experiment the animals had histological tests of the tissues around endoprosthesis components. Results and conclusions: After one-stage bilateral total hip replacement in early terms of research more expressed changes of bone tissue in the form of its thinning and decompaction were found around implants. One-stage bilateral total hip replacement did not essentially influence on the speed of osteogenesis around endoprothesis components in comparison with unilateral total hip replacement, so in late terms of observation in both groups the fixing of endoprothesis components did not differ.

  10. Ultrasound-Guided Hip Arthrocentesis in a Child with Hip Pain and Fever

    Directory of Open Access Journals (Sweden)

    James H. Moak

    2012-09-01

    Full Text Available Children presenting to the emergency department with hip pain and fever are at risk for significant morbidity due to septic arthritis. Distinguishing between septic arthritis and other causes of hip pain may be challenging. Sonographic visualization of the hip with real-time ultrasound-guided arthrocentesis may allow faster differentiation between etiologies, hastening definitive therapy and improving analgesia. This report describes the use of hip sonography in a case of Lyme arthritis. The authors review the medical literature in support of bedside hip sonography and discuss how to perform ultrasound-guided hip arthrocentesis. Clinical findings in septic and Lyme arthritis are also described.

  11. BILATERAL PATHOLOGICAL HIP DISLOCATION IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Yuriy E. Garkavenko

    2017-03-01

    Full Text Available Introduction. Pathological dislocation of the hip is one of the most severe complications of acute hematogenous osteomyelitis. The program of treatment for children with pathological hip dislocation is complex, but it has been sufficiently developed and implemented very successfully. At the same time, the available literature provides no cases of treating children with bilateral pathological hip dislocations after hematogenous osteomyelitis. There is no information on the incidence of such cases or in regards to remote functional results. Materials and methods. The results of the treatment of 18 children with bilateral pathological dislocation of the hip after hematogenous osteomyelitis are presented, which constituted 23.1% of the total number of patients (78 who underwent surgery in 2000–2016 for the diagnosis of pathological hip dislocation. Both hip joints were surgically operated on in 12 patients, while one hip joint was operated on in 6 patients. To assess the anatomical and functional state of hip joints, the clinical and roentgenological diagnostic techniques were used. Results and discussion. To stabilize and restore the function of the hip joints, 18 children underwent 30 surgical interventions: simple open hip reduction (19 and open hip reduction with hip arthroplasty with one (6 or two (5 demineralized osteochondral allogeneic grafts. The decision regarding the possibility of performing surgical intervention on the second hip joint was made only after a child's check-up examination was complete and after positive information about the anatomical and functional state of the operated hip joint was obtained. According to these criteria, 14 (77.8% children underwent surgical treatment of the second hip joint 1–1.5 years after the course of conservative measures to restore the range of motion in the previously operated hip joint. Over a period of 1–12 years, 17 patients were examined, 10 of which underwent an operation on both

  12. Chronic Periprosthetic Hip Joint Infection

    DEFF Research Database (Denmark)

    Lange, Jeppe; Troelsen, Anders; Søballe, Kjeld

    2016-01-01

    INTRODUCTION: Limited information is available regarding the treatment strategy and prognosis of non-selected patients treated for chronic periprosthetic hip joint infection. Such information is important as no head-to-head studies on treatment strategies are available. The purpose of this study...... is to report on the treatment strategy and prognosis of a non-selected, consecutive patient population. METHODS: We identified 130 patients in the National Patient Registry, consecutively treated for a chronic periprosthetic hip joint infection between 2003-2008 at 11 departments of orthopaedic surgery. We...... chart review with a minimum of 5 years follow-up by the nationwide electronic patient record system. RESULTS: After primary revision surgery, 53 patients (41%) had a spacer in situ, 64 (50%) had a resection arthroplasty and 13 (9%) did not have the infected implant removed. 63% were re...

  13. Hip fractures in old men

    International Nuclear Information System (INIS)

    Martinez Rondanelli, Alfredo

    2005-01-01

    Describe 289 hip fractures that were admitted at Hospital Universitario del Valle between November 1, 2003 and June 30, 2004. The patients had the first appointment at 2.7 days after the fallen, 60% the patients were women, at he age average were 75 years. In the hospital 228 patients were operated (79%). The surgery was realized in average at the twelve days after than they were admitted at the hospital. The days in the hospital were in average 17.5 days. The index of Katz at the admission was 3.96 and the Parker index was 6.56. The mortality in the hospital was of 30 patients (11%). The following during six months was in 114 patients of the people that were operated; we found loss of initial reduction the hip fracture in 10% and infection in 4%

  14. The Danish Hip Arthroplasty Register

    DEFF Research Database (Denmark)

    Gundtoft, Per Hviid; Varnum, Claus; Pedersen, Alma Becic

    2016-01-01

    AIM OF DATABASE: The aim of the Danish Hip Arthroplasty Register (DHR) is to continuously monitor and improve the quality of treatment of primary and revision total hip arthroplasty (THA) in Denmark. STUDY POPULATION: The DHR is a Danish nationwide arthroplasty register established in January 1995...... complications. Completeness of primary and revision surgery is evaluated annually and validation of a number of variables has been carried out. DESCRIPTIVE DATA: A total of 139,525 primary THAs and 22,118 revisions have been registered in the DHR between January 1, 1995 and December 31, 2014. Since 1995....... All Danish orthopedic departments - both public and private - report to the register, and registration is compulsory. MAIN VARIABLES: The main variables in the register include civil registration number, indication for primary and revision surgery, operation date and side, and postoperative...

  15. Editorial Commentary: Anatomical Vandalism of the Hip? Hip Capsular Repair Seems a Sound Adjunct to Hip Arthroscopic Surgery.

    Science.gov (United States)

    van Arkel, Richard J; Jeffers, Jonathan R T; Amis, Andrew A

    2017-02-01

    The study "Contribution of the Pubofemoral Ligament to Hip Stability: A Biomechanical Study" by Martin, Khoury, Schröder, Johnson, Gómez-Hoyos, Campos, and Palmer found that cutting the hip capsular ligament allowed a large increase in femoral internal rotation, particularly in the flexed hip, causing subluxation to occur. In addition to providing new data on the role of the pubofemoral ligament, it raises the question of whether hip joint surgeons should repair the capsule-what are the likely consequences?-and whether any beneficial effects persist in long-term clinical follow-ups. For now, hip capsular repair seems a sound adjunct to hip arthroscopic surgery. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  16. Do Changes in Patellofemoral Joint Offset Lead to Adverse Outcomes in Total Knee Arthroplasty With Patellar Resurfacing? A Radiographic Review.

    Science.gov (United States)

    Matz, Jacob; Howard, James L; Morden, David J; MacDonald, Steven J; Teeter, Matthew G; Lanting, Brent A

    2017-03-01

    Patellofemoral joint biomechanics contribute to anterior knee pain, instability, and dysfunction following total knee arthroplasty (TKA). Information about specific factors leading to anterior knee pain and dysfunction is currently limited. Changes in patellofemoral joint offset (PFO) refers to a mismatch between the preoperative and postoperative anteroposterior geometry of the patellofemoral joint. It remains unclear whether these changes lead to adverse outcomes in TKA. A retrospective radiographic review of 970 knees pre-TKA and post-TKA was completed to correlate the radiographic and clinical outcomes of changing the PFO using a posterior-stabilized single knee design with patellar resurfacing. A total of 970 patients were reviewed. Postoperatively, the anterior femoral offset, anteroposterior femoral size, and anterior patellar offset were changed in 40%, 60%, and 71% of knees, respectively, compared to preoperative values. The Western Ontario and McMasters Osteoarthritis Index total score as well as subscale scores for pain and function were not significantly affected by an increase or decrease in PFO. Similarly, Knee Society Scores and range of motion were not significantly affected. Increased anterior patellar offset was, however, associated with increased postoperative patellar tilt. Postoperative patellar tilt was not correlated with adverse patient satisfaction scores or loss of range of motion. Changes in PFO (decreased, maintained, or increased) are common post-TKA and are not associated with a difference in clinical outcomes. Increases in anterior patellar offset led to increased patellar tilt, which was not associated with adverse patient satisfaction scores. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Gross and microscopic findings in patients submitted to nonablative full-face resurfacing using intense pulsed light: a preliminary study.

    Science.gov (United States)

    Hernández-Pérez, Enrique; Ibiett, Erick Valencia

    2002-08-01

    Intense pulsed light (IPL) is a noncoherent, nonlaser, filtered flashlamp emitting a broadband visible light that has been shown to be effective in photoepilation, as well as in a number of vascular and pigmented lesions of the skin. Their efficacy has also been reported recently in the treatment of photodamaged facial skin. In the last condition, however, there are few studies showing the clinical and microscopic changes produced by IPL. To assess the gross and microscopic changes that occur in photodamaged skin submitted to nonablative full-face resurfacing (NAFFR) using IPL. Five women were submitted to five NAFFR sessions using IPL, one every 2 weeks. Skin biopsies and photographs were taken on all of the patients before the first procedure and after the last one, as well as weekly clinical assessment. Data concerning skin features (wrinkles, oiliness, thickness, dilated pores, and general appearance) were all assessed. Microscopic improvement of the aging features in the epidermis and dermis were all assessed. For the statistical analysis a t test for small samples was used. All the patients showed clinical and microscopic improvement in every one of the parameters assessed. The t test for small samples showed a statistically significant difference (P Facial photodamage was clinically and microscopically improved using IPL. Use of IPL as a rejuvenating method seems to be promising, with minimal side effects, a wide safety margin, and minimal downtime.

  18. A Pilot Study of Skin Resurfacing Using the 2,790-nm Erbium:YSGG Laser System

    Directory of Open Access Journals (Sweden)

    Jong Won Rhie

    2015-01-01

    Full Text Available BackgroundThe erbium:yttrium scandium gallium garnet (Er:YSGG laser differs from other laser techniques by having a faster and higher cure rate. Since the Er:YSGG laser causes an appropriate proportion of ablation and coagulation, it has advantages over the conventional carbon dioxide (CO2 laser and the erbium-doped yttrium aluminum garnet (Er:YAG laser, including heating tendencies and explosive vaporization. This research was conducted to explore the effects and safety of the Er:YSGG laser.MethodsTwenty patients participated in the pilot study of a resurfacing system using a 2,790-nm Er:YSGG laser. All patients received facial treatment by the 2,790-nm Er:YSGG laser system (Cutera twice with a 4-week interval. Wrinkle reduction, reduction in pigment inhomogeneity, and improvement in tone and texture were measured.ResultsStudy subjects included 15 women and five men. Re-epithelization occurred in all subjects 3 to 4 days after treatment, and wrinkle reduction, reduction in pigment inhomogeneity, and improvement in tone and texture within 6 months of treatment.ConclusionsThe 2,790-nm YSGG laser technique had fewer complications and was effective in the improvement of scars, pores, wrinkles, and skin tone and color with one or two treatments. We expect this method to be effective for people with acne scars, pore scars, deep wrinkles, and uneven skin texture and color.

  19. Prospective, pilot evaluation of the performance of nanofractional radiofrequency for improvement of skin texture via skin resurfacing.

    Science.gov (United States)

    Bohnert, Krista; Dorizas, Andrew; Sadick, Neil

    2018-02-01

    The latest generation of radiofrequency, nanofractional radiofrequency, allows the heat energy to be delivered through the use of pins or needles as electrodes, facilitating increased efficacy and reduced pain, downtime, and side effects. The objective of this prospective pilot clinical study was to evaluate the efficacy of nanofractional radiofrequency in skin resurfacing. Seventeen subjects were enrolled in the study, and each received three nanofractional radiofrequency (160-pin tip) treatments in the facial area at 3-week intervals. Follow-up visits were scheduled at 1 and 2 months after the final treatment. Clinical photography, patient, and investigator assessments were conducted during the treatment visits and follow-up. All subjects completed the study. At the 1- and 2-month follow-up, there was a moderate to significant improvement (2.6 and 3.5, respectively, P = .01) according to the investigator global esthetic improvement scale rating. Most subjects reported that they were satisfied or very satisfied with the outcome and level of comfort. Nanofractional radiofrequency is a safe and effective strategy for improving texture, tone, and skin laxity with high patient satisfaction and tolerable safety profile. © 2017 Wiley Periodicals, Inc.

  20. Fractional nonablative 1,540-nm laser resurfacing of atrophic acne scars. A randomized controlled trial with blinded response evaluation

    DEFF Research Database (Denmark)

    Hedelund, Lene; Moreau, Karen Estell R; Beyer, Ditte M

    2010-01-01

    fractional laser treatment of acne scars. Ten patients with acne scars were included. Two intraindividual areas of similar size and appearance within contralateral anatomical regions were randomized to (1) 3-monthly laser treatments with a StarLux 1,540-nm fractional handpiece, and (2) no treatment. Blinded...... appeared more even and smooth than untreated control areas (4.5, 2-6.5, versus 6.5, 4.5-8, P=0.0156, at 4 weeks; 4.5, 2.5-6.5, versus 6.5, 4.5-8, at 12 weeks; P=0.0313). Patients were satisfied with the treatment (5.5, 1-7, after 12 weeks) and five of the ten patients evaluated their acne scars......The efficacy of nonablative fractional laser resurfacing of acne scars has been described in case reports and uncontrolled trials. The present study is the first randomized controlled trial in this field. The aim of this study was to examine the efficacy and adverse effects of 1,540-nm nonablative...

  1. Treatment of cosmetic tattoos using carbon dioxide ablative fractional resurfacing in an animal model: a novel method confirmed histopathologically.

    Science.gov (United States)

    Wang, Chia-Chen; Huang, Chuen-Lin; Sue, Yuh-Mou; Lee, Shao-Chen; Leu, Fur-Jiang

    2013-04-01

    Treating cosmetic tattoos using quality-switched lasers is difficult. We used carbon dioxide ablative fractional resurfacing (CO2 AFR) to remove cosmetic tattoos and examined the pathophysiologic mechanisms involved in this technique in an animal model. Twelve rats were tattooed on their backs with white and flesh-colored pigments. Half of each tattoo was treated with CO2 AFR (5 sessions at 1-month intervals), and the other half was the untreated control. An independent observer reviewed photographic documentation of clinical response. Serial skin samples obtained at baseline and at various times after laser treatment were evaluated using histologic and immunohistochemical methods. Four rats had excellent responses to laser treatment and eight had good responses. White and flesh-colored tattoos had similar clearance rates and tissue reactions. Histologic analysis showed immediate ablation of tattoo pigments in the microscopic ablation zones. Tattoo pigments in the microscopic coagulation zones migrated to the epidermis and became part of the microscopic exudative necrotic debris appearing on day 2 that was exfoliated after 5 days. Increased fibronectin expression around the microscopic treatment zones during the extrusion of tattoo pigments indicated that wound healing facilitates this action. CO2 AFR successfully removes cosmetic tattoos. © 2012 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.

  2. Fractional nonablative 1,540-nm laser resurfacing of atrophic acne scars. A randomized controlled trial with blinded response evaluation

    DEFF Research Database (Denmark)

    Hedelund, Lene; Moreau, Karen Estell R; Beyer, Ditte M

    2010-01-01

    The efficacy of nonablative fractional laser resurfacing of acne scars has been described in case reports and uncontrolled trials. The present study is the first randomized controlled trial in this field. The aim of this study was to examine the efficacy and adverse effects of 1,540-nm nonablative...... fractional laser treatment of acne scars. Ten patients with acne scars were included. Two intraindividual areas of similar size and appearance within contralateral anatomical regions were randomized to (1) 3-monthly laser treatments with a StarLux 1,540-nm fractional handpiece, and (2) no treatment. Blinded...... appeared more even and smooth than untreated control areas (4.5, 2-6.5, versus 6.5, 4.5-8, P=0.0156, at 4 weeks; 4.5, 2.5-6.5, versus 6.5, 4.5-8, at 12 weeks; P=0.0313). Patients were satisfied with the treatment (5.5, 1-7, after 12 weeks) and five of the ten patients evaluated their acne scars...

  3. A Hip Implant Energy Harvester

    Science.gov (United States)

    Pancharoen, K.; Zhu, D.; Beeby, S. P.

    2014-11-01

    This paper presents a kinetic energy harvester designed to be embedded in a hip implant which aims to operate at a low frequency associated with body motion of patients. The prototype is designed based on the constrained volume available in a hip prosthesis and the challenge is to harvest energy from low frequency movements (< 1 Hz) which is an average frequency during free walking of a patient. The concept of magnetic-force-driven energy harvesting is applied to this prototype considering the hip movements during routine activities of patients. The magnetic field within the harvester was simulated using COMSOL. The simulated resonant frequency was around 30 Hz and the voltage induced in a coil was predicted to be 47.8 mV. A prototype of the energy harvester was fabricated and tested. A maximum open circuit voltage of 39.43 mV was obtained and the resonant frequency of 28 Hz was observed. Moreover, the power output of 0.96 μW was achieved with an optimum resistive load of 250Ω.

  4. Dosimetric influence of hip prosthesis during radiotherapeutic treatment

    International Nuclear Information System (INIS)

    Gschwind, R.; Buffard, E.; Masset, H.; Makovicka, L.; David, C.; David, C.; Buffard, E.

    2008-01-01

    As the population become aged, many patients with hip prosthesis are treated for a pelvic cancer. The recommended ballistic must avoid to pass in the prosthesis, but sometimes it is inevitable. So it is essential to quantify with accuracy the dose modifications linked to the presence of metallic implant. The aim of this study is to analyze by Monte Carlo method these modifications in simple and complex models (anthropomorphic phantom) which take into account the geometry and the composition of the prosthesis and its coatings. Then, this methodology was used to study the behaviour of a treatment planning system in theses extreme conditions. (authors)

  5. Cover Story: The Miseducation of Hip-Hop.

    Science.gov (United States)

    Evelyn, Jamilah

    2000-01-01

    Some higher education officials believe that hip-hop music is eating away at the morals, and ultimately the classroom experience, of today's college students. Discusses why the gap exists between student and faculty attitudes toward hip-hop, how hip-hop music represents blackness, how people perceive hip-hop youth, the positive side of hip-hop,…

  6. Infection or metal hypersensitivity? The diagnostic challenge of failure in metal-on-metal bearings.

    LENUS (Irish Health Repository)

    Galbraith, John G

    2011-04-01

    The use of second generation metal-on-metal hip articulations has gained favour in the past few years. A hypersensitivity reaction to the metal-on-metal bearing, although rare, is a reported complication and is a novel mode of failure of these implants. Differentiating failure secondary to infection from failure secondary to metal hypersensitivity represents a significant diagnostic challenge. A retrospective review of all cases of hip arthroplasty using metal-on-metal bearings over a 5-year period at a tertiary referral centre identified 3 cases of failure secondary to metal hypersensitivity. Clinical presentation, serological markers, radiological imaging and histological analysis of all cases identified were evaluated. Histological analysis of periprosthetic tissue in all 3 cases identified characteristic features such as perivascular lymphocytic aggregates and chronic inflammation consistent with aseptic lymphocytic vasculitis-associated lesions (ALVAL). This study highlights that failure secondary to metal hypersensitivity must be considered in patients presenting with the reappearance of persistent pain, marked joint effusion, and the development of early osteolysis in the absence of infection.

  7. CT osteodensitometry in the area directly adjacent to hip endoprotheses

    International Nuclear Information System (INIS)

    Sokiranski, R.; Marienfeld, D.; Felsenberg, D.; Rilinger, N.; Goerich, J.; Kalender, W.

    1996-01-01

    Purpose: The value of metal artifact reduction in quantitative bone density determination in the vicinity of metallic implants was studied. Method: Ten cadaver femora with hip endoprostheses implanted intra vitam were examined in CT with varying slice thicknesses, tube voltage, scan time and magnification factor. The artifact-laden images were then processed using a metal artifact reduction programme (MAR). The metallic implant was removed, allowing the bone slices to be examined again with the same imaging parameters, but without the bothersome metal artifacts. This allowed comparison of bone density values obtained before and after application of MAR with data obtained after implant removal. Results: A comparison of the bone density measurements between the sample group without implants and the group with indwelling implants prior to MAR showed an unexpected correlation coefficient r=0.975-0.977. The correlation coefficients after MAR rose to r=0.987-0.992 in 125 kV and r=0.989-0.991 in 85 kV modes. The reproducibility of the density measurements for the groups without implants and with implants following MAR showed variation coefficients (VC) of 1.16% and 0.75% respectively. The reproducibility of the manual definition of the region of interest (ROI) in bone showed a VC=2.19%. Conclusions: Bone density in the vicinity of metallic implants can be reliably and reproducibly determined using MAR. (orig.) [de

  8. Physiopathology and biomechanics of hip osteoarthritis

    Directory of Open Access Journals (Sweden)

    M. Cutolo

    2011-09-01

    Full Text Available Several factors seem to play a relevant role in the pathogenesis of hip osteoarthritis. Among these, an altered biomechanic and neuromuscular integrity of the hip joint should be considered. This is a review of the recent international literature concerning the role of loads and strengths acting on the hip joint, in order to better understand the pathogenesis and the physiopathology of the hip osteoarthritis. The study of these factors might be important to prevent the development of the osteoarthritis and might suggest the conservative treatment. In particular, the role of the balance among the muscles working in maintaining the equilibrium of the acting strengths is matter of discussion. The articular and neuromuscular dysfunction might induce an altered load distribution in the hip, particularly on the articular cartilage surface, and seems to favour the development of hip osteoarthritis...

  9. Clinical results of cementless total hip arthroplasty with shortening osteotomy for high dislocation with developmental dysplasia.

    Science.gov (United States)

    Desteli, Engin Eren; Imren, Yunus; Tan, Erkan; Erdoğan, Murat; Özcan, Hüseyin

    2015-03-01

    Total hip arthroplasty for severe developmental dysplasia of the hip is a technically challenging procedure. Subtrochanteric femoral osteotomy enables reducing the femoral head and restoring abductor muscle strength without compromising proximal femoral bone stock in advanced dysplasia.We aimed to retrospectively evaluate Crowe type III or IV developmental dysplasia of the hip who underwent reconstruction with cementless total hip arthroplasty combined with a transverse subtrochanteric femoral osteotomy. Sixty hips of 52 patients (11 male, 49 female) with Crowe type III (n: 37) or IV (n: 23) developmental dysplasia of the hip were included. The average age was 51.4 years. Surgery was performed in lateral decubitis position with posterolateral approach. Subtrochanteric transverse femoral osteotomy were used with cementless components. 40 of the femoral components were Secur-Fit type, and 20 of them were secur-fit plus max type. Ceramic-ceramic coupling was used in 24 cases and metal-polyethylene coupling was used in 36 cases. Merle D'Aubigne and Harris Hip score were used to rate the clinical outcome at the final follow up. All femoral shortening osteotomies were united at a mean of 5.7 months. Mean Merle D'Aubigne pain score was increased from 3.1 to 5.4, and mean Harris Hip score improved from 39 to 92.8, postoperatively (p<0.01). There was no significant difference in time to union between different types of stems. 4 femoral stems had asymptomatic radiolucent lines. There was no significant difference in time to union between different types of stems.

  10. Hip Surgery Candidates: A Comparative Study of Hip Osteoarthritis and Prior Hip Fracture Patient Characteristics

    OpenAIRE

    Marks, Ray

    2008-01-01

    Aim: To assess similarities and differences in patient-related characteristics before and after surgery for painful disabling hip osteoarthritis among elderly subgroups with and without a trauma history. Method: First, a cohort of 1000 hospitalized patients were assessed for trends in: perceived duration of the condition, pain intensity, functional performance ability, walking distance, body mass, and comorbidity characteristics among other factors. Then, the most salient of these patient-rel...

  11. Imaging findings of anterior hip dislocations

    Energy Technology Data Exchange (ETDEWEB)

    Pfeifer, Kyle [Mallinckrodt Institute of Radiology, Department of Radiology, St. Louis, MO (United States); Leslie, Michael [Yale School of Medicine, Department of Orthopedics and Rehabilitation, New Haven, CT (United States); Menn, Kirsten; Haims, Andrew [Yale University School of Medicine, Department of Radiology and Biomedical Imaging, New Haven, CT (United States)

    2017-06-15

    Anterior hip dislocations are rare orthopedic emergencies resulting from high-energy trauma and have unique imaging characteristics on radiography, computed tomography (CT), and magnetic resonance imaging (MRI). Imaging findings on CT and MRI allow for the prompt recognition and classification of anterior hip dislocations, which guides patient management and reduces complications. The purpose of this article is to review imaging findings of anterior hip dislocations, specifically focusing on CT and MRI. (orig.)

  12. Imaging findings of anterior hip dislocations

    International Nuclear Information System (INIS)

    Pfeifer, Kyle; Leslie, Michael; Menn, Kirsten; Haims, Andrew

    2017-01-01

    Anterior hip dislocations are rare orthopedic emergencies resulting from high-energy trauma and have unique imaging characteristics on radiography, computed tomography (CT), and magnetic resonance imaging (MRI). Imaging findings on CT and MRI allow for the prompt recognition and classification of anterior hip dislocations, which guides patient management and reduces complications. The purpose of this article is to review imaging findings of anterior hip dislocations, specifically focusing on CT and MRI. (orig.)

  13. Immediate Effect of Grade IV Inferior Hip Joint Mobilization on Hip Abductor Torque: A Pilot Study

    OpenAIRE

    Makofsky, Howard; Panicker, Siji; Abbruzzese, Jeanine; Aridas, Cynthia; Camp, Michael; Drakes, Jonelle; Franco, Caroline; Sileo, Ray

    2007-01-01

    Joint mobilization and manipulation stimulate mechanoreceptors, which may influence the joint and surrounding muscles. The purpose of this pilot study was to determine the effect of grade IV inferior hip joint mobilization on hip abductor torque. Thirty healthy subjects were randomly assigned to a control group (grade I inferior hip joint mobilization) or an experimental group (grade IV inferior hip joint mobilization). Subjects performed a pre- and post-intervention test of five isometric re...

  14. Fatal cobalt toxicity after total hip arthroplasty revision for fractured ceramic components.

    Science.gov (United States)

    Fox, Kimberly A; Phillips, Todd M; Yanta, Joseph H; Abesamis, Michael G

    2016-11-01

    Post-arthroplasty metallosis, which refers to metallic corrosion and deposition of metallic debris in the periprosthetic soft tissues of the body, is an uncommon complication. Systemic cobalt toxicity post-arthroplasty is extremely rare. The few known fatal cases of cobalt toxicity appear to be a result of replacing shattered ceramic heads with metal-on-metal or metal-on-polyethylene implants. Friction between residual shards of ceramic and cobalt-chromium implants allows release of cobalt into the synovial fluid and bloodstream, resulting in elevated whole blood cobalt levels and potential toxicity. This is a single patient chart review of a 60-year-old woman with prior ceramic-on-ceramic right total hip arthroplasty complicated by fractured ceramic components and metallosis of the joint. She underwent synovectomy and revision to a metal-on-polyethylene articulation. Ten months post-revision, she presented to the emergency department (ED) with right hip pain, dyspnea, worsening hearing loss, metallic dysgeusia, and weight loss. Chest CTA revealed bilateral pulmonary emboli (PE), and echocardiogram revealed new cardiomyopathy with global left ventricular hypokinesis with an ejection fraction (EF) of 35-40% inconsistent with heart strain from PE. Whole blood cobalt level obtained two days into her admission was 424.3 mcg/L and 24-h urine cobalt level was 4830.5 mcg/L. Although the patient initially clinically improved with regard to her PE and was discharged to home on hospital day 5, she returned 10 days later with a right hip dislocation and underwent closed reduction of the hip. The patient subsequently decompensated, developing cardiogenic shock, and respiratory failure. She went into pulseless electrical activity (PEA) and expired. Autopsy revealed an extensive metallic effusion surrounding the right hip prosthesis that tested positive for cobalt (41,000 mcg/L). There was also cobalt in the heart muscle tissue (2.5 mcg/g). A whole blood cobalt level

  15. Life Estimation of Hip Joint Prosthesis

    Science.gov (United States)

    Desai, C.; Hirani, H.; Chawla, A.

    2014-11-01

    Hip joint is one of the largest weight-bearing structures in the human body. In the event of a failure of the natural hip joint, it is replaced with an artificial hip joint, known as hip joint prosthesis. The design of hip joint prosthesis must be such so as to resist fatigue failure of hip joint stem as well as bone cement, and minimize wear caused by sliding present between its head and socket. In the present paper an attempt is made to consider both fatigue and wear effects simultaneously in estimating functional-life of the hip joint prosthesis. The finite element modeling of hip joint prosthesis using HyperMesh™ (version 9) has been reported. The static analysis (load due to the dead weight of the body) and dynamic analysis (load due to walking cycle) have been described. Fatigue life is estimated by using the S-N curve of individual materials. To account for progressive wear of hip joint prosthesis, Archard's wear law, modifications in socket geometry and dynamic analysis have been used in a sequential manner. Using such sequential programming reduction in peak stress has been observed with increase in wear. Finally life is estimated on the basis of socket wear.

  16. Life Estimation of Hip Joint Prosthesis

    Science.gov (United States)

    Desai, C.; Hirani, H.; Chawla, A.

    2015-07-01

    Hip joint is one of the largest weight-bearing structures in the human body. In the event of a failure of the natural hip joint, it is replaced with an artificial hip joint, known as hip joint prosthesis. The design of hip joint prosthesis must be such so as to resist fatigue failure of hip joint stem as well as bone cement, and minimize wear caused by sliding present between its head and socket. In the present paper an attempt is made to consider both fatigue and wear effects simultaneously in estimating functional-life of the hip joint prosthesis. The finite element modeling of hip joint prosthesis using HyperMesh™ (version 9) has been reported. The static analysis (load due to the dead weight of the body) and dynamic analysis (load due to walking cycle) have been described. Fatigue life is estimated by using the S-N curve of individual materials. To account for progressive wear of hip joint prosthesis, Archard's wear law, modifications in socket geometry and dynamic analysis have been used in a sequential manner. Using such sequential programming reduction in peak stress has been observed with increase in wear. Finally life is estimated on the basis of socket wear.

  17. COMPLEX FUNCTIONAL ASSESSMENT OF THE HIP JOINT.

    Directory of Open Access Journals (Sweden)

    Maya S. Krastanova

    2015-09-01

    Full Text Available Introduction: In relation to the study reporting the effects of applying phased complex rehabilitation in patients with total hip arthroplasty, it has been concluded that the everyday clinical practice in Bulgaria does not apply complex examination, giving an objective picture about the extent of functional status of patients with trauma and diseases of the hip. Aim: The main goal of this