WorldWideScience

Sample records for meniscal repair techniques

  1. Meniscal repair devices.

    Science.gov (United States)

    Barber, F A; Herbert, M A

    2000-09-01

    Meniscal repair devices not requiring accessory incisions are attractive. Many factors contribute to their clinical effectiveness including their biomechanical characteristics. This study compared several new meniscal repair devices with standard meniscal suture techniques. Using a porcine model, axis-of-insertion loads were applied to various meniscal sutures and repair devices. A single device or stitch was placed in a created meniscal tear and a load applied. Both loads and modes of failure were recorded. The load-to-failure data show stratification into 4 distinct statistical groups. Group A, 113 N for a double vertical stitch; group B, 80 N for a single vertical stitch; group C, 57 N for the BioStinger, 56 N for a horizontal mattress stitch, and 50 N for the T-Fix stitch; and group D, 33 N for the Meniscus Arrow (inserted by hand or gun), 32 N for the Clearfix screw, 31 N for the SDsorb staple, 30 N for the Mitek meniscal repair system, and 27 N for the Biomet staple. The failure mechanism varied. Sutures broke away from the knot. The Meniscus Arrow and BioStinger pulled through the inner rim with the crossbar intact. The Clearfix screw failed by multiple mechanisms, whereas 1 leg of the SDsorb staple always pulled out of the outer rim. The Mitek device usually failed by pullout from the inner rim. The Biomet staple always broke at the crosshead or just below it. Although the surgeon should be aware of the material properties of the repair technique chosen for a meniscal repair, this information is only an indication of device performance and may not correlate with clinical healing results.

  2. Success of Meniscal Repair at ACL Reconstruction

    Science.gov (United States)

    Toman, Charles; Spindler, Kurt P.; Dunn, Warren R.; Amendola, Annunziata; Andrish, Jack T.; Bergfeld, John A.; Flanigan, David; Jones, Morgan; Kaeding, Christopher C.; Marx, Robert G.; Matava, Matthew J.; McCarty, Eric C.; Parker, Richard D.; Wolcott, Michelle; Vidal, Armando; Wolf, Brian R.; Huston, Laura J.; Harrell, Frank E.; Wright, Rick W.

    2013-01-01

    Background Meniscal repair is performed in an attempt to prevent posttraumatic arthritis resulting from meniscal dysfunction after meniscal tears. The socioeconomic implications of premature arthritis are significant in the young patient population. Investigations and techniques focusing on meniscus preservation and healing are now at the forefront of orthopaedic sports medicine. Hypothesis Concomitant meniscal repair with ACL reconstruction is a durable and successful procedure at two year follow-up. Study Design Case Series; Level of evidence, 4. Methods All unilateral primary ACL reconstructions entered in 2002 in a prospective cohort who had meniscal repair at the time of ACLR were evaluated. Validated patient oriented outcome instruments were completed preoperatively and then again at the two-year postoperative time point. Reoperation after the index procedure was also documented and confirmed by operative reports. Results 437 unilateral primary ACL reconstructions were performed with 86 concomitant meniscal repairs (57 medial, 29 lateral) in 84 patients during the study period. Patient follow-up was obtained on 94% (81/86) of the meniscal repairs, allowing confirmation of meniscal repair success (defined as no repeat arthroscopic procedure) or failure. The overall success rate for meniscal repairs was 96% (76/79 patients) at two-year follow-up. Conclusions Meniscal repair is a successful procedure in conjunction with ACL reconstruction. When confronted with a “repairable” meniscal tear at the time of ACL reconstruction, orthopaedic surgeons can expect an estimated >90% clinical success rate at two-year follow-up using a variety of methods as shown in our study. PMID:19465734

  3. Biomechanical testing of new meniscal repair techniques containing ultra high-molecular weight polyethylene suture.

    Science.gov (United States)

    Barber, F Alan; Herbert, Morley A; Schroeder, F Alexander; Aziz-Jacobo, Jorge; Sutker, Michael J

    2009-09-01

    To evaluate the biomechanical characteristics of current meniscal repair techniques containing ultra high-molecular weight polyethylene (UHMWPE) suture with and without cyclic loading. Vertical longitudinal cuts made in porcine menisci were secured with a single repair device. Noncycled and cycled (500 cycles) biomechanical tests were performed on the following groups: group 1, No. 2-0 Mersilene vertical suture (Ethicon, Somerville, NJ); group 2, No. 2-0 Orthocord vertical suture (DePuy Mitek, Westwood, MA); group 3, No. 0 Ultrabraid vertical suture (Smith & Nephew Endoscopy, Andover, MA); group 4, No. 2-0 FiberWire vertical suture (Arthrex, Naples, FL); group 5, vertically oriented mattress suture by use of an Ultra FasT-Fix device (Smith & Nephew Endoscopy) with No. 0 Ultrabraid; group 6, vertically oriented mattress suture by use of a RapidLoc A2 device (DePuy Mitek) with No. 2-0 Orthocord suture; group 7, vertically oriented stitch by use of a MaxFire device with MaxBraid PE suture (Biomet Sports Medicine, Warsaw, IN); and group 8, an obliquely oriented stitch of No. 0 UHMWPE suture inserted by use of a CrossFix device (Cayenne Medical, Scottsdale, AZ). Endpoints were failure loads, failure modes, stiffness, and cyclic displacement. Mean single-pull loads were calculated for Ultra FasT-Fix (121 N), FiberWire (110 N), MaxFire (130 N), Mersilene (84 N), Orthocord (124 N), RapidLoc A2 (86 N), CrossFix (77 N), and Ultrabraid (109 N). After 500 cyclic loads, the Orthocord (222 N) repair was stronger than the others: Ultra FasT-Fix (110 N), FiberWire (117 N), MaxFire (132 N), Mersilene (89 N), RapidLoc A2 (108 N), CrossFix (95 N), and Ultrabraid (126 N) (P Fix, RapidLoc A2, and MaxFire) were comparable to the isolated UHMWPE-containing suture repairs on single-failure load testing. UHMWPE-containing suture repairs are stronger than braided polyester suture repairs, but pure UHMWPE suture (Ultrabraid) elongated more during cycling. Orthocord suture is significantly

  4. A biomechanical evaluation of all-inside 2-stitch meniscal repair devices with matched inside-out suture repair.

    Science.gov (United States)

    Ramappa, Arun J; Chen, Alvin; Hertz, Benjamin; Wexler, Michael; Grimaldi Bournissaint, Leandro; DeAngelis, Joseph P; Nazarian, Ara

    2014-01-01

    Many all-inside suture-based devices are currently available, including the Meniscal Cinch, FasT-Fix, Ultra FasT-Fix, RapidLoc, MaxFire, and CrossFix System. These different devices have been compared in various configurations, but to our knowledge, the Sequent meniscal repair device, which applies running sutures, has not been compared with the Ultra FasT-Fix, nor has it been compared with its suture, No. 0 Hi-Fi, using an inside-out repair technique. To assess the quality of the meniscal repair, all new devices should be compared with the gold standard: the inside-out repair. To that end, this study aims to compare the biomechanical characteristics of running sutures delivered by the Sequent meniscal repair device with 2 vertical mattress sutures applied using the Ultra FasT-Fix device and with 2 vertical mattress sutures using an inside-out repair technique with No. 0 Hi-Fi suture. Controlled laboratory study. Paired (medial and lateral), fresh-frozen porcine menisci were randomly assigned to 1 of 3 groups: Sequent (n = 17), Ultra FasT-Fix (n = 19), and No. 0 Hi-Fi inside-out repair (n = 20). Bucket-handle tears were created in all menisci and were subjected to repair according to their grouping. Once repaired, the specimens were subjected to cyclic loading (100, 300, and 500 cycles), followed by loading to failure. The Sequent and Ultra FasT-Fix device repairs and the suture repair exhibited low initial displacements. The Sequent meniscal repair device demonstrated the lowest displacement in response to cyclic loading. No. 0 Hi-Fi suture yielded the highest load to failure. With the development of the next generation of all-inside meniscal repair devices, surgeons may use these findings to select the method best suited for their patients. The Sequent meniscal repair device displays the least amount of displacement during cyclic loading but has a similar failure load to other devices.

  5. KNEE PROPRIOCEPTION FOLLOWING MENISCAL REPAIR

    Directory of Open Access Journals (Sweden)

    Brytsko A. A.

    2018-02-01

    Full Text Available Background. It is well known that meniscectomy leads to osteoarthritis of the knee and proprioception impairment. Objective. The aim of this study was to assess retrospectively the joint position sense after meniscal suture and partial medial meniscal resection and to estimate the patients’ satisfaction with knee function. Material and Methods. We evaluated the outcomes of 27 patients after meniscal repair and compared them to those of 24 patients after partial meniscal resection. We estimated the joint position sense at 30°, 45° and 60° of flexion using the Biodex system 4 Pro. All patients were assessed with the IKDC 2000 subjective knee score. Results. A statistically significant worsening in reproducing the injured joint position in comparison to the healthy limb in both groups was observed. These impairments were mostly expressed at 45° and 60° of knee flexion, and were worsening over time in the group of patients who had undergone medial meniscal resection. An average value by the IKDC 2000 scale after 24 months in the meniscorrhaphy group was 76.73 ± 11.17% and 68.93 ± 14.76% after partial medial meniscal resection. Сonclusion. The control over position of the knee is not impaired after meniscal repair. An overall satisfaction with joint function is higher in patients who undergo meniscal suture in comparison to the partial medial meniscal resection group.

  6. Meniscal repair following meniscectomy: Mechanism and protective effect

    International Nuclear Information System (INIS)

    Berjon, J.J.; Munuera, L.; Calvo, M.

    1990-01-01

    Meniscal repair was studied to evaluate the mechanism and its potential protective effects on the articular cartilage in an experimental model consisting of 68 knees of adult dogs on which five different types of medial meniscectomy were performed. The results were assessed by macroscopic, microangiographic, and histological methods, after a sequential follow-up period of 10-450 days. Two different mechanisms of meniscal repair were observed, depending on whether meniscal section had been performed in vascular (total meniscectomy) or avascular (subtotal or partial meniscectomy) zones. It was also observed that the repaired meniscal tissue does not prevent articular cartilage degeneration. This is more closely related to the size of the meniscal fragment preserved at meniscetomy. Due to the biomechanical importance of the meniscus and the lack of functional relevance of the repaired meniscal tissue, the most conservative approach possible to meniscectomy is recommended. (orig.)

  7. Successful anterior cruciate ligament reconstruction and meniscal repair in osteogenesis imperfecta.

    Science.gov (United States)

    Park, Jae-Young; Cho, Tae-Joon; Lee, Myung Chul; Han, Hyuk-Soo

    2018-03-20

    A case of anterior cruciate ligament (ACL) reconstruction with meniscal repair in an osteogenesis imperfecta patient is reported. A 24-year-old female with osteogenesis imperfecta type 1a suffered from a valgus extension injury resulting in tear of ACL and medial meniscus. She underwent an arthroscopic-assisted ACL reconstruction and medial meniscus repair. Meniscal tear at the menisco-capsular junction of the posterior horn of medial meniscus was repaired with three absorbable sutures via inside-out technique. ACL reconstruction was then performed with a bone-patellar tendon-bone allograft. The patient was followed up for 1 year with intact ACL grafts and healed medial meniscus. This case report showed that successful ACL reconstruction and meniscal repair is possible in an osteogenesis imperfecta patient.Level of evidence V.

  8. Meniscal tears, repairs and replacement: their relevance to osteoarthritis of the knee.

    Science.gov (United States)

    McDermott, Ian

    2011-04-01

    The menisci of the knee are important load sharers and shock absorbers in the joint. Meniscal tears are common, and whenever possible meniscal tears should be surgically repaired. Meniscectomy leads to a significant increased risk of osteoarthritis, and various options now exist for replacing missing menisci, including the use of meniscal scaffolds or the replacement of the entire meniscus by meniscal allograft transplantation. The field of meniscal surgery continues to develop apace, and the future may lie in growing new menisci by tissue engineering techniques.

  9. Similar failure rate in immediate post-operative weight bearing versus protected weight bearing following meniscal repair on peripheral, vertical meniscal tears.

    Science.gov (United States)

    Perkins, Bryan; Gronbeck, Kyle R; Yue, Ruixian Alexander; Tompkins, Marc A

    2017-08-16

    Post-operative weight bearing after meniscal repair is a point of debate among physicians. This study sought to evaluate whether patients adhering to an immediate WBAT rehabilitation programme have a higher failure rate compared to those adhering to a more traditional, protected, NWB status following meniscal repair. The null hypothesis was that there would be no difference in failure between the two groups. A retrospective review of meniscal repair patients greater than 5 years from surgery was performed for patients receiving meniscal repair treatment. Patients were categorized by post-surgical weight-bearing status, either NWB or WBAT, and then analysed for failure of repair. Failure was defined as re-operation on the torn meniscus. The study controlled for variables including age at surgery, sex, height, weight, and BMI, classification of tear type, acuity of the tear, repair location (medial or lateral), repair location within the meniscus, repair technique, and concomitant procedures. Re-operations were performed in 61 of 157 patients [38.9%]. There was no difference between weight-bearing groups for failure of meniscus repair (n.s.). The tears were acute vertical tears located in the posterior horn and body. For the 61 patients with re-operation, the average time to re-operation was 2.2 years with 10 [16%] > 5 years from surgery, 17 [28%] 2-5 years from surgery, and 34 [56%] bearing groups for rate of re-operation (n.s.). Weight bearing as tolerated after meniscal repair for peripheral, vertical tears does not result in a higher failure rate than traditional, non-weight bearing over a five-year follow-up period. The clinical relevance is that, based on these data, it may be appropriate to allow weight bearing as tolerated following meniscal repair of peripheral, vertical tears. Retrospective cohort study, Level III.

  10. Cell Based Meniscal Repair Using an Aligned Bioactive Nanofibrous Sheath

    Science.gov (United States)

    2017-07-01

    to subsequently guide tissue regeneration , for example, by seeded tissue progenitor cells . To achieve this objective, the first step is to develop...AWARD NUMBER: W81XWH-15-1-0104 TITLE: Cell -Based Meniscal Repair Using an Aligned Bioactive Nanofibrous Sheath PRINCIPAL INVESTIGATOR...SUBTITLE 5a. CONTRACT NUMBER Cell -Based Meniscal Repair Using an Aligned Bioactive Nanofibrous Sheath 5b. GRANT NUMBER W81XWH-15-1-0104 5c. PROGRAM

  11. Development of a Micronized Meniscus Extracellular Matrix Scaffold for Potential Augmentation of Meniscal Repair and Regeneration.

    Science.gov (United States)

    Monibi, Farrah A; Bozynski, Chantelle C; Kuroki, Keiichi; Stoker, Aaron M; Pfeiffer, Ferris M; Sherman, Seth L; Cook, James L

    2016-12-01

    Decellularized scaffolds composed of extracellular matrix (ECM) hold promise for repair and regeneration of the meniscus, given the potential for ECM-based biomaterials to aid in stem cell recruitment, infiltration, and differentiation. The objectives of this study were to decellularize canine menisci to fabricate a micronized, ECM-derived scaffold and to determine the cytocompatibility and repair potential of the scaffold ex vivo. Menisci were decellularized with a combination of physical agitation and chemical treatments. For scaffold fabrication, decellularized menisci were cryoground into a powder and the size and morphology of the ECM particles were evaluated using scanning electron microscopy. Histologic and biochemical analyses of the scaffold confirmed effective decellularization with loss of proteoglycan from the tissue but no significant reduction in collagen content. When washed effectively, the decellularized scaffold was cytocompatible to meniscal fibrochondrocytes, synoviocytes, and whole meniscal tissue based on the resazurin reduction assay and histologic evaluation. In an ex vivo model for meniscal repair, radial tears were augmented with the scaffold delivered with platelet-rich plasma as a carrier, and compared to nonaugmented (standard-of-care) suture techniques. Histologically, there was no evidence of cellular migration or proliferation noted in any of the untreated or standard-of-care treatment groups after 40 days of culture. Conversely, cellular infiltration and proliferation were noted in scaffold-augmented repairs. These data suggest the potential for the scaffold to promote cellular survival, migration, and proliferation ex vivo. Further investigations are necessary to examine the potential for the scaffold to induce cellular differentiation and functional meniscal fibrochondrogenesis.

  12. Longitudinal follow-up of patients with conservatively treated and arthroscopically repaired peripheral meniscal tears

    International Nuclear Information System (INIS)

    Deutsch, A.L.; Mink, J.H.; Rothman, B.J.

    1989-01-01

    Tears involving the peripheral third of the meniscus represent an important subgroup of meniscal injuries due to their unique ability to heal by synovial ingrowth and vascular proliferation. Serial MR images were obtained in 14 patients with arthroscopically proved peripheral meniscal tears to assess changes in MR appearance associated with meniscal healing. Six patients were treated conservatively, and eight underwent arthroscopic repair. All patients were considered clinically stable and presumably healed based on commonly accepted orthopedic criteria. Persistent grade 3 signal was seen in all patients up to 6 months after injury. In two patients more than 14 months after repair, grade 3 signal was present but decreased. In no patient did the signal entirely resolve. The authors concluded that signal from conservatively treated and repaired meniscal tears may persist long after the tear has become asymptomatic and presumable healed. This likely reflects known histologic differences between the native meniscus and reparative fibrocartilage. Persistence of grade 3 signal should not be interpreted as reflective of nonhealing in patients with persistent symptoms or as evidence of another tear in those with recurrent symptoms

  13. Surgical interventions for meniscal tears: a closer look at the evidence.

    Science.gov (United States)

    Mutsaerts, Eduard L A R; van Eck, Carola F; van de Graaf, Victor A; Doornberg, Job N; van den Bekerom, Michel P J

    2016-03-01

    The aim of the present study was to compare the outcomes of various surgical treatments for meniscal injuries including (1) total and partial meniscectomy; (2) meniscectomy and meniscal repair; (3) meniscectomy and meniscal transplantation; (4) open and arthroscopic meniscectomy and (5) various different repair techniques. The Bone, Joint and Muscle Trauma Group Register, Cochrane Database, MEDLINE, EMBASE and CINAHL were searched for all (quasi) randomized controlled clinical trials comparing various surgical techniques for meniscal injuries. Primary outcomes of interest included patient-reported outcomes scores, return to pre-injury activity level, level of sports participation and persistence of pain using the visual analogue score. Where possible, data were pooled and a meta-analysis was performed. A total of nine studies were included, involving a combined 904 subjects, 330 patients underwent a meniscal repair, 402 meniscectomy and 160 a collagen meniscal implant. The only surgical treatments that were compared in homogeneous fashion across more than one study were the arrow and inside-out technique, which showed no difference for re-tear or complication rate. Strong evidence-based recommendations regarding the other surgical treatments that were compared could not be made. This meta-analysis illustrates the lack of level I evidence to guide the surgical management of meniscal tears. Level I meta-analysis.

  14. Meniscectomy versus meniscal repair: 10 years radiological and clinical results in vertical lesions in stable knee.

    Science.gov (United States)

    Lutz, C; Dalmay, F; Ehkirch, F P; Cucurulo, T; Laporte, C; Le Henaff, G; Potel, J F; Pujol, N; Rochcongar, G; Salledechou, E; Seil, R; Gunepin, F-X; Sonnery-Cottet, B

    2015-12-01

    Surgical management of meniscal lesion consists of either a meniscectomy or meniscal repair. Although repair offers immediate recovery after surgery, it is also associated with higher rates of revision. A meniscectomy, on the other hand is known to be associated with an early onset of osteoarthritis. The present study compared clinical and radiological results at 10 years between meniscectomy and meniscal repair in isolated vertical lesion in an otherwise stable knee. The hypothesis was that repair shows functional and radiological benefit over meniscectomy. A multi-centric retrospective comparative study of 32 patients (24 male, 8 female). Mean follow-up was 10.6 years (range, 10-13 years). There were 10 meniscal repairs (group R) and 22 meniscectomies (group M), in 17 right and 15 left knees. Mean age at surgery was 33.45±12.3 years (range, 9-47 years). There were 28 medial and 4 lateral meniscal lesions; 26 were in the red-red zone and 6 in red-white zone. Functional score: KOOS score was significantly higher in group R than M on almost all parameters: 98±4.69 versus 77.38±21.97 for symptoms (P=0.0043), 96.89±7.20 versus 78.57±18.9 for pain (P=0.0052), 99.89±0.33 versus 80.88±19.6 for daily life activities (P=0.0002), 96.11±9.83 versus 54.05±32.85 for sport and leisure (P=0.0005), but 91±16.87 versus 68.15±37.7 for quality of life (P=0.1048). Radiology score: in group R, 7 patients had no features of osteoarthritis, and 2 had grade 1 osteoarthritis. In group M, 5 patients had grade 1 osteoarthritis, 10 grade 2, 3 grade 3 and 3 grade 4. Mean quantitative score was 0 (mean, 0.22±0.44) in-group R and 2 (mean, 2.19±0.98) in group M (P<0.0001). At more than 10year's follow-up, functional scores were significantly better with meniscal repair than meniscectomy on all parameters of the KOOS scale except quality of life. Functional and radiological scores correlated closely. These results show that meniscal repair for vertical lesions in stable knees

  15. Clinical Results of Arthroscopic Repair of Isolated Longitudinal Tear of Medial Meniscus by Vertical Cruciate Double Mattress Sutures with Outside-in Technique

    Directory of Open Access Journals (Sweden)

    Seyied Hamid Barzgar

    2013-09-01

    Full Text Available Introduction : Meniscal tears are one of the most common injuries treated by arthroscopic techniques. Arthroscopic meniscal repair is an accepted way of treatment for meniscal tears. Different arthroscopic techniques for meniscal repair are: inside-out, outside-in and all inside. In the first 2 techniques, meniscus is repaired by sutures and in the later by suture or by commercial ready implants . The goal of current study is assessing clinical results of arthroscopic repair of longitudinal meniscal tears with vertical cruciate double mattress sutures by outside-in technique after 9 months.   Methods: In this case series study, in 13 patients having criteria for engaging the study with longitudinal isolated meniscus tear, arthroscopic meniscal repair was done with vertical cruciate double mattress sutures by outside-in technique and patients were followed for 9 months.   Results: Of 13 patients, there were 12 males (92.3% and one female (7.7% aged 15-38 (average 28.3 years. In follow up period, there was one case (7.7% of irritation by subcutaneous knot. There was not any failure of repair. Average Lysholm score increased from 55.23 to 91.23 after 9 months of follow up, which was statistically significant (p<0.001. At the end of follow up period, there was not any medial joint line tenderness of knee, giving way or significant effusion or pain.   Conclusion: This study shows that this technique has a good short term outcome with no failure and low complications but it is necessary to do more long term studies to prove it.

  16. Arthroscopic all-inside meniscal repair - Does the meniscus heal? A clinical and radiological follow-up examination to verify meniscal healing using a 3-T MRI

    Energy Technology Data Exchange (ETDEWEB)

    Hoffelner, Thomas; Resch, Herbert; Mayer, Michael; Tauber, Mark [Department of Traumatology and Sports Injuries, Salzburg (Austria); Forstner, Rosemarie [University Hospital of Salzburg, Department of Radiology, Salzburg (Austria); Minnich, Bernd [University of Salzburg, Department of Organismic Biology, Salzburg (Austria)

    2011-02-15

    The purpose of this study was to correlate clinical and radiological results using a 3-T MRI to verify meniscal healing after arthroscopic all-inside meniscus repair. We selected 27 patients (14 men and 13 women) with an average age of 31 {+-} 9 years and retrospective clinical examinations and radiological assessments using a 3-T MRI after all-inside arthroscopic meniscal repair were conducted. Repair of the medial meniscus was performed in 19 patients and of the lateral meniscus in eight. In 17 patients (63%), we performed concomitant anterior cruciate ligament reconstruction. The mean follow-up period was 4.5 {+-} 1.7 years. The Lysholm score and Tegner activity index were used for clinical evaluation. Four grades were used to classify the radiological signal alterations within the meniscus: central globular (grade 1); linear horizontal or band-like (grade 2); intrameniscal alterations and linear signal alterations communicating with the articular surface (grade 3); and complex tears (grade 4). At follow-up, the average Lysholm score was 76 {+-} 15 points, with ten of the patients placed in group 6 based on the Tegner activity index. MRI examinations revealed no signal alteration in three patients, grade 1 in 0, grade 2 in five, grade 3 in 13, and grade 4 in six. The MRI findings correlated positively with the clinical scores in 21 patients (78%). Correlation of clinical and radiological examination was performed using 3-T MRI. In spite of satisfactory clinical outcomes at follow-up, a radiological signal alteration may still be visible on MRI, which was believed to be scar tissue, but could not be proven definitively. Imaging with a 3-Tesla MRI after meniscal suture surgery provides good but no definitive reliability on meniscus healing and therefore gives no advantage compared to 1.5-T MRI, with good clinical outcome using an all-inside arthroscopic meniscal repair. 3T-MRI can not substitute diagnostic arthroscopy in patients with persistent complaints after

  17. Arthroscopic all-inside meniscal repair - Does the meniscus heal? A clinical and radiological follow-up examination to verify meniscal healing using a 3-T MRI

    International Nuclear Information System (INIS)

    Hoffelner, Thomas; Resch, Herbert; Mayer, Michael; Tauber, Mark; Forstner, Rosemarie; Minnich, Bernd

    2011-01-01

    The purpose of this study was to correlate clinical and radiological results using a 3-T MRI to verify meniscal healing after arthroscopic all-inside meniscus repair. We selected 27 patients (14 men and 13 women) with an average age of 31 ± 9 years and retrospective clinical examinations and radiological assessments using a 3-T MRI after all-inside arthroscopic meniscal repair were conducted. Repair of the medial meniscus was performed in 19 patients and of the lateral meniscus in eight. In 17 patients (63%), we performed concomitant anterior cruciate ligament reconstruction. The mean follow-up period was 4.5 ± 1.7 years. The Lysholm score and Tegner activity index were used for clinical evaluation. Four grades were used to classify the radiological signal alterations within the meniscus: central globular (grade 1); linear horizontal or band-like (grade 2); intrameniscal alterations and linear signal alterations communicating with the articular surface (grade 3); and complex tears (grade 4). At follow-up, the average Lysholm score was 76 ± 15 points, with ten of the patients placed in group 6 based on the Tegner activity index. MRI examinations revealed no signal alteration in three patients, grade 1 in 0, grade 2 in five, grade 3 in 13, and grade 4 in six. The MRI findings correlated positively with the clinical scores in 21 patients (78%). Correlation of clinical and radiological examination was performed using 3-T MRI. In spite of satisfactory clinical outcomes at follow-up, a radiological signal alteration may still be visible on MRI, which was believed to be scar tissue, but could not be proven definitively. Imaging with a 3-Tesla MRI after meniscal suture surgery provides good but no definitive reliability on meniscus healing and therefore gives no advantage compared to 1.5-T MRI, with good clinical outcome using an all-inside arthroscopic meniscal repair. 3T-MRI can not substitute diagnostic arthroscopy in patients with persistent complaints after

  18. Meniscal injuries in the young, athletically active patient.

    Science.gov (United States)

    Poulsen, Matthew R; Johnson, Darren L

    2011-02-01

    Meniscal injuries are common in young physically active individuals, particularly those who are involved in contact level 1 sports that involve frequent pivoting, such as soccer and American football. This is a unique population because of their high physical activity at a young age, and it is important that correct diagnosis and appropriate treatment are provided, as the medial and lateral menisci are essential for normal knee function. In this article, we review the anatomy and function of the meniscus, the epidemiology of meniscal tears, and mechanism(s) of injury. Important concomitant injuries are also discussed. When making a diagnosis, relevant patient history, physical examination, and appropriate imaging studies are required. Nonoperative treatment is rarely successful for treating meniscal tears in young athletes, and therefore repair of the torn menisci is often required. We also discuss partial resection (which should only be performed when repair is not possible), as well as rehabilitation protocols after repair has been performed. All of these factors associated with meniscal injuries are important for a physician when diagnosing and treating these often complex injuries.

  19. A Contact Pressure Analysis Comparing an All-Inside and Inside-Out Surgical Repair Technique for Bucket-Handle Medial Meniscus Tears.

    Science.gov (United States)

    Marchetti, Daniel Cole; Phelps, Brian M; Dahl, Kimi D; Slette, Erik L; Mikula, Jacob D; Dornan, Grant J; Bucci, Gabriella; Turnbull, Travis Lee; Singleton, Steven B

    2017-10-01

    To directly compare effectiveness of the inside-out and all-inside medial meniscal repair techniques in restoring native contact area and contact pressure across the medial tibial plateau at multiple knee flexion angles. Twelve male, nonpaired (n = 12), fresh-frozen human cadaveric knees underwent a series of 5 consecutive states: (1) intact medial meniscus, (2) MCL tear and repair, (3) simulated bucket-handle longitudinal tear of the medial meniscus, (4) inside-out meniscal repair, and (5) all-inside meniscal repair. Knees were loaded with a 1,000-N axial compressive force at 5 knee flexion angles (0°, 30°, 45°, 60°, 90°), and contact area, mean contact pressure, and peak contact pressure were calculated using thin film pressure sensors. No significant differences were observed between the inside-out and all-inside repair techniques at any flexion angle for contact area, mean contact pressure, and peak contact pressure (all P > .791). Compared with the torn meniscus state, inside-out and all-inside repair techniques resulted in increased contact area at all flexion angles (all P contact pressure at all flexion angles (all P contact pressure at all flexion angles (all P contact area and peak contact pressure between the intact state and inside-out technique at angles ≥45° (all P contact area at 60° and 90° and peak contact pressure at 90° (both P contact area, mean contact pressure, and peak contact pressure over the tested flexion angles ranged from 498 to 561 mm 2 , 786 to 997 N/mm 2 , and 1,990 to 2,215 N/mm 2 , respectively. Contact area, mean contact pressure, and peak contact pressure were not significantly different between the all-inside and inside-out repair techniques at any tested flexion angle. Both techniques adequately restored native meniscus biomechanics near an intact level. An all-inside repair technique provided similar, native-state-restoring contact mechanics compared with an inside-out repair technique for the treatment of

  20. Meniscal tears: comparison of half-Fourier technique and conventional MR imaging

    International Nuclear Information System (INIS)

    Shabana, Wael; Maeseneer, Michel de; Machiels, Freddy; Ridder, Filip de; Osteaux, Michel

    2003-01-01

    Purpose: To determine whether half-Fourier MR image acquisition technique can provide similar information to that of conventional MR acquisition technique for evaluation of meniscal tears. Materials and methods: We studied 101 menisci in 52 patients who were referred for evaluation of meniscal tears. Sagittal MR images of the knee were obtained for all patients by using proton density and T2-weighted SE sequences on a 1-T clinical system. The half-Fourier technique and conventional technique were used for all patients. All other imaging parameters were identical for both sequences (TR/TE=2400/20,70; 3 mm slice thickness; 200x256 matrix; field of view, 200; one signal acquired). Both sets of images were filmed with standard window and level settings. Images were randomised and interpreted independently by two radiologists for the presence of meniscal tears. Images were also subjectively assessed for image quality using a five-point grading scale. Results: On half-Fourier images, Reader 1 interpreted 23 menisci as torn, compared to 28 for Reader 2. On conventional images, Reader 1 interpreted 24 menisci as torn, compared to 26 for Reader 2. Agreement between interpretation of the conventional and that of the half-Fourier images was 99% for Reader 1, and 98% for Reader 2. Agreement between readers for the half-Fourier images was 95%, and for the conventional images 96%. No statistically significant difference was found in the subjective evaluation of image quality between the conventional and half-Fourier images. Conclusion: The half-Fourier acquisition technique compares favourably with the conventional technique for the evaluation of meniscal tears

  1. The potential of optical coherence tomography for diagnosing meniscal pathology

    Science.gov (United States)

    Hang-Yin Ling, Carrie; Pozzi, Antonio; Thieman, Kelley M.; Tonks, Catherine A.; Guo, Shuguang; Xie, Huikai; Horodyski, MaryBeth

    2010-04-01

    Meniscal tears are often associated with anterior cruciate ligament (ACL) injury and may lead to pain and discomfort in humans. Maximal preservation of meniscal tissue is highly desirable to mitigate the progression of osteoarthritis. Guidelines of which meniscal tears are amenable to repair and what part of damaged tissues should be removed are elusive and lacking consensus. Images of microstructural changes in meniscus would potentially guide the surgeons to manage the meniscal tears better, but the resolution of current diagnostic techniques is limited for this application. In this study, we demonstrated the feasibility of using optical coherence tomography (OCT) for the diagnosis of meniscal pathology. Torn medial menisci were collected from dogs with ACL insufficiency. The torn meniscus was divided into three tissue samples and scanned by OCT and scanning electron microscopy (SEM). OCT and SEM images of torn menisci were compared. Each sample was evaluated for gross and microstructural abnormalities and reduction or loss of birefringence from the OCT images. The abnormalities detected with OCT were described for each type of tear. OCT holds promise in non-destructive and fast assessment of microstructural changes and tissue birefringence of meniscal tears. Future development of intraoperative OCT may help surgeons in the decision making of meniscal treatment.

  2. The potential of optical coherence tomography for diagnosing meniscal pathology

    International Nuclear Information System (INIS)

    Ling, Carrie Hang-Yin; Horodyski, MaryBeth; Pozzi, Antonio; Thieman, Kelley M; Tonks, Catherine A; Guo, Shuguang; Xie, Huikai

    2010-01-01

    Meniscal tears are often associated with anterior cruciate ligament (ACL) injury and may lead to pain and discomfort in humans. Maximal preservation of meniscal tissue is highly desirable to mitigate the progression of osteoarthritis. Guidelines of which meniscal tears are amenable to repair and what part of damaged tissues should be removed are elusive and lacking consensus. Images of microstructural changes in meniscus would potentially guide the surgeons to manage the meniscal tears better, but the resolution of current diagnostic techniques is limited for this application. In this study, we demonstrated the feasibility of using optical coherence tomography (OCT) for the diagnosis of meniscal pathology. Torn medial menisci were collected from dogs with ACL insufficiency. The torn meniscus was divided into three tissue samples and scanned by OCT and scanning electron microscopy (SEM). OCT and SEM images of torn menisci were compared. Each sample was evaluated for gross and microstructural abnormalities and reduction or loss of birefringence from the OCT images. The abnormalities detected with OCT were described for each type of tear. OCT holds promise in non-destructive and fast assessment of microstructural changes and tissue birefringence of meniscal tears. Future development of intraoperative OCT may help surgeons in the decision making of meniscal treatment

  3. Quantifying meniscal kinematics in dogs.

    Science.gov (United States)

    Park, Brian H; Banks, Scott A; Pozzi, Antonio

    2017-11-06

    The dog has been used extensively as an experimental model to study meniscal treatments such as meniscectomy, meniscal repair, transplantation, and regeneration. However, there is very little information on meniscal kinematics in the dog. This study used MR imaging to quantify in vitro meniscal kinematics in loaded dog knees in four distinct poses: extension, flexion, internal, and external rotation. A new method was used to track the meniscal poses along the convex and posteriorly tilted tibial plateau. Meniscal displacements were large, displacing 13.5 and 13.7 mm posteriorly on average for the lateral and medial menisci during flexion (p = 0.90). The medial anterior horn and lateral posterior horns were the most mobile structures, showing average translations of 15.9 and 15.1 mm, respectively. Canine menisci are highly mobile and exhibit movements that correlate closely with the relative tibiofemoral positions. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  4. A Novel Repair Method for Radial Tears of the Medial Meniscus: Biomechanical Comparison of Transtibial 2-Tunnel and Double Horizontal Mattress Suture Techniques Under Cyclic Loading.

    Science.gov (United States)

    Bhatia, Sanjeev; Civitarese, David M; Turnbull, Travis Lee; LaPrade, Christopher M; Nitri, Marco; Wijdicks, Coen A; LaPrade, Robert F

    2016-03-01

    Complete radial tears of the medial meniscus have been reported to be functionally similar to a total meniscectomy. At present, there is no consensus on an ideal technique for repair of radial midbody tears of the medial meniscus. Prior attempts at repair with double horizontal mattress suture techniques have led to a reportedly high rate of incomplete healing or healing in a nonanatomic (gapped) position, which compromises the ability of the meniscus to withstand hoop stresses. A newly proposed 2-tunnel radial meniscal repair method will result in decreased gapping and increased ultimate failure loads compared with the double horizontal mattress suture repair technique under cyclic loading. Controlled laboratory study. Ten matched pairs of male human cadaveric knees (average age, 58.6 years; range, 48-66 years) were used. A complete radial medial meniscal tear was made at the junction of the posterior one-third and middle third of the meniscus. One knee underwent a horizontal mattress inside-out repair, while the contralateral knee underwent a radial meniscal repair entailing the same technique with a concurrent novel 2-tunnel repair. Specimens were potted and mounted on a universal testing machine. Each specimen was cyclically loaded 1000 times with loads between 5 and 20 N before experiencing a load to failure. Gap distances at the tear site and failure load were measured. The 2-tunnel repairs exhibited a significantly stronger ultimate failure load (median, 196 N; range, 163-212 N) than did the double horizontal mattress suture repairs (median, 106 N; range, 63-229 N) (P = .004). In addition, the 2-tunnel repairs demonstrated decreased gapping at all testing states (P meniscus significantly decrease the ability of the meniscus to dissipate tibiofemoral loads, predisposing patients to early osteoarthritis. Improving the ability to repair medial meniscal radial tears in a way that withstands cyclic loads and heals in an anatomic position could significantly

  5. Surgical interventions for meniscal tears: a closer look at the evidence

    NARCIS (Netherlands)

    Mutsaerts, Eduard L. A. R.; van Eck, Carola F.; van de Graaf, Victor A.; Doornberg, Job N.; van den Bekerom, Michel P. J.

    2016-01-01

    The aim of the present study was to compare the outcomes of various surgical treatments for meniscal injuries including (1) total and partial meniscectomy; (2) meniscectomy and meniscal repair; (3) meniscectomy and meniscal transplantation; (4) open and arthroscopic meniscectomy and (5) various

  6. T-Fix endoscopic meniscal repair: technique and approach to different types of tears.

    Science.gov (United States)

    Barrett, G R; Richardson, K; Koenig, V

    1995-04-01

    Endoscopic meniscus repair using the T-Fix suture device (Acufex Microsurgical, Inc, Mansfield, MA) allows ease of suture placement for meniscus stability without the problems associated with ancillary incisions such as neurovascular compromise. It is ideal for the central posterior horn tears that are difficult using conventional techniques. Vertical tears, bucket handle tears, flap tears, and horizontal tears can be approached using a temporary "anchor stitch" to stabilize the meniscus before T-Fix repair. The basic method of repair and our approach to these different types of tears is presented.

  7. Potential Market for New Meniscus Repair Strategies: Evaluation of the MOON Cohort

    Science.gov (United States)

    Fetzer, Gary B.; Spindler, Kurt P.; Amendola, Annunziato; Andrish, Jack T.; Bergfeld, John A.; Dunn, Warren R.; Flanigan, David C.; Jones, Morgan; Kaeding, Christopher C.; Marx, Robert G.; Matava, Matthew J.; McCarty, Eric C.; Parker, Richard D.; Wolcott, Michelle; Vidal, Armando; Wolf, Brian R.; Wright, Rick W.

    2013-01-01

    be treated with an advanced repair technique, and 35% of medial meniscal tears and 62% of lateral meniscal tears could be treated with scaffold replacement. Conclusions Although meniscal preservation is a generally accepted concept in the treatment of meniscal tears, the majority of tears in this young cohort undergoing ACL reconstruction were either not repairable types (radial) and/or in the avascular zone. Even with contemporary approaches to meniscal tear repair, we found significant limitations faced by the treating surgeon. The majority of tears in this population are currently treated by partial meniscectomy. The results of this cohort will hopefully, stimulate and focus future research and development of new tissue engineering strategies for a large potential market for meniscal function in an ACL reconstructed cohort. PMID:19634719

  8. Meniscal pathology in children: differences and similarities with the adult meniscus

    Energy Technology Data Exchange (ETDEWEB)

    Francavilla, Michael L.; Restrepo, Ricardo; Zamora, Kathryn W.; Sarode, Vijaya [Department of Radiology, Miami Children' s Hospital, Miami, FL (United States); Swirsky, Stephen M. [Department of Orthopedics, Miami Children' s Hospital, Miami, FL (United States); Mintz, Douglas [Hospital for Special Surgery, New York, NY (United States)

    2014-08-15

    The normal meniscus undergoes typical developmental changes during childhood, reaching a mature adult appearance by approximately 10 years of age. In addition to recognizing normal meniscal appearances in children, identifying abnormalities - such as tears and the different types of discoid meniscus and meniscal cysts, as well as the surgical implications of these abnormalities - is vital in pediatric imaging. The reported incidence of meniscal tears in adolescents and young adults has increased because of increased sports participation and more widespread use of MRI. This review discusses the normal appearance of the pediatric meniscus, meniscal abnormalities, associated injuries, and prognostic indicators for repair. (orig.)

  9. Meniscal pathology in children: differences and similarities with the adult meniscus

    International Nuclear Information System (INIS)

    Francavilla, Michael L.; Restrepo, Ricardo; Zamora, Kathryn W.; Sarode, Vijaya; Swirsky, Stephen M.; Mintz, Douglas

    2014-01-01

    The normal meniscus undergoes typical developmental changes during childhood, reaching a mature adult appearance by approximately 10 years of age. In addition to recognizing normal meniscal appearances in children, identifying abnormalities - such as tears and the different types of discoid meniscus and meniscal cysts, as well as the surgical implications of these abnormalities - is vital in pediatric imaging. The reported incidence of meniscal tears in adolescents and young adults has increased because of increased sports participation and more widespread use of MRI. This review discusses the normal appearance of the pediatric meniscus, meniscal abnormalities, associated injuries, and prognostic indicators for repair. (orig.)

  10. MR imaging-based diagnosis and classification of meniscal tears.

    Science.gov (United States)

    Nguyen, Jie C; De Smet, Arthur A; Graf, Ben K; Rosas, Humberto G

    2014-01-01

    Magnetic resonance (MR) imaging is currently the modality of choice for detecting meniscal injuries and planning subsequent treatment. A thorough understanding of the imaging protocols, normal meniscal anatomy, surrounding anatomic structures, and anatomic variants and pitfalls is critical to ensure diagnostic accuracy and prevent unnecessary surgery. High-spatial-resolution imaging of the meniscus can be performed using fast spin-echo and three-dimensional MR imaging sequences. Normal anatomic structures that can mimic a tear include the meniscal ligament, meniscofemoral ligaments, popliteomeniscal fascicles, and meniscomeniscal ligament. Anatomic variants and pitfalls that can mimic a tear include discoid meniscus, meniscal flounce, a meniscal ossicle, and chondrocalcinosis. When a meniscal tear is identified, accurate description and classification of the tear pattern can guide the referring clinician in patient education and surgical planning. For example, longitudinal tears are often amenable to repair, whereas horizontal and radial tears may require partial meniscectomy. Tear patterns include horizontal, longitudinal, radial, root, complex, displaced, and bucket-handle tears. Occasionally, meniscal tears can be difficult to detect at imaging; however, secondary indirect signs, such as a parameniscal cyst, meniscal extrusion, or linear subchondral bone marrow edema, should increase the radiologist's suspicion for an underlying tear. Awareness of common diagnostic errors can ensure accurate diagnosis of meniscal tears. Online supplemental material is available for this article. ©RSNA, 2014.

  11. Meniscal transplantation: still experimental surgery? A review.

    Science.gov (United States)

    Moens, K; Dhollander, A; Moens, P; Verdonk, K; Verdonk, R; Almqvist, K F; Victor, J

    2014-09-01

    The objective of this review is to give a state of affairs of meniscal transplantation, with the accent on preservation and surgical techniques. All articles were selected by performing a search on the literature by using relevant keywords. The most relevant articles were selected with close attention to the publication date. When a meniscal tear is diagnosed, suture can be an option in the vascular zone, whereas the more frequently affected avascular zone heals poorly. A meniscectomy however is not without consequences, wherefore meniscal transplantation can be seen as a therapeutic option for pain reduction and improvement of function when the meniscus is lost. The meniscal scaffold, allograft and autograft can be currently withheld as possible grafts, where the meniscal scaffolds hold great promise as an alternative to the allograft. Various fixation techniques are therefore developed, where viable, deep frozen as well as cryopreservated allografts seem to give the most promising short term results. The transplantation can be performed using an open as well as an arthroscopic technique, using soft tissue fixation, bone plugs or blocks. De primacy of one technique can't be proven. In general meniscal transplantation can be considered as an acceptable procedure. Since the outcomes of different studies are difficult to compare, an attempt should be made to limit new studies to the comparison of one aspect. We can conclude that larger, more comparative randomised controlled long-term studies are necessary to resolve which techniques can give the best long-term results.

  12. Analysis of meniscal degeneration and meniscal gene expression

    Directory of Open Access Journals (Sweden)

    Norton James H

    2010-01-01

    Full Text Available Abstract Background Menisci play a vital role in load transmission, shock absorption and joint stability. There is increasing evidence suggesting that OA menisci may not merely be bystanders in the disease process of OA. This study sought: 1 to determine the prevalence of meniscal degeneration in OA patients, and 2 to examine gene expression in OA meniscal cells compared to normal meniscal cells. Methods Studies were approved by our human subjects Institutional Review Board. Menisci and articular cartilage were collected during joint replacement surgery for OA patients and lower limb amputation surgery for osteosarcoma patients (normal control specimens, and graded. Meniscal cells were prepared from these meniscal tissues and expanded in monolayer culture. Differential gene expression in OA meniscal cells and normal meniscal cells was examined using Affymetrix microarray and real time RT-PCR. Results The grades of meniscal degeneration correlated with the grades of articular cartilage degeneration (r = 0.672; P HLA-DPA1, integrin, beta 2 (ITGB2, ectonucleotide pyrophosphatase/phosphodiesterase 1 (ENPP1, ankylosis, progressive homolog (ANKH and fibroblast growth factor 7 (FGF7, were expressed at significantly higher levels in OA meniscal cells compared to normal meniscal cells. Importantly, many of the genes that have been shown to be differentially expressed in other OA cell types/tissues, including ADAM metallopeptidase with thrombospondin type 1 motif 5 (ADAMTS5 and prostaglandin E synthase (PTGES, were found to be expressed at significantly higher levels in OA meniscal cells. This consistency suggests that many of the genes detected in our study are disease-specific. Conclusion Our findings suggest that OA is a whole joint disease. Meniscal cells may play an active role in the development of OA. Investigation of the gene expression profiles of OA meniscal cells may reveal new therapeutic targets for OA therapy and also may uncover novel

  13. Chondral Injuries and Irreparable Meniscal Tears Among Adolescents With Anterior Cruciate Ligament or Meniscal Tears Are More Common in Patients With Public Insurance.

    Science.gov (United States)

    Williams, Ariel A; Mancini, Nickolas S; Solomito, Matthew J; Nissen, Carl W; Milewski, Matthew D

    2017-07-01

    Access to health care services is a critical component of health care reform and may differ among patients with different types of insurance. Hypothesis/Purpose: The purpose was to compare adolescents with private and public insurance undergoing surgery for anterior cruciate ligament (ACL) and/or meniscal tears. We hypothesized that patients with public insurance would have a delayed presentation from the time of injury and therefore would have a higher incidence of chondral injuries and irreparable meniscal tears and lower preoperative International Knee Documentation Committee (IKDC) scores than patients with private insurance. Cross-sectional study; Level of evidence, 3. This was a retrospective study of patients under 21 years of age undergoing ACL reconstruction and/or meniscal repair or debridement from January 2013 to March 2016 at a single pediatric sports medicine center. Patients were identified by a search of Current Procedural Terminology (CPT) codes. A chart review was performed for insurance type; preoperative diagnosis; date of injury, initial office visit, and surgery; preoperative IKDC score; intraoperative findings; and procedures. The study group consisted of 119 patients (mean age, 15.0 ± 1.7 years). Forty-one percent of patients had private insurance, while 59% had public insurance. There were 27 patients with isolated meniscal tears, 59 with combined meniscal and ACL tears, and 33 with isolated ACL tears. The mean time from injury to presentation was 56 days (range, 0-457 days) in patients with private insurance and 136 days (range, 0-1120 days) in patients with public insurance ( P = .02). Surgery occurred, on average, 35 days after the initial office visit in both groups. The mean preoperative IKDC score was 53 in both groups. Patients with meniscal tears with public insurance were more likely to require meniscal debridement than patients with private insurance (risk ratio [RR], 2.3; 95% CI, 1.7-3.1; P = .02). Patients with public insurance

  14. Meniscal allograft transplantation: a meta-analysis

    Directory of Open Access Journals (Sweden)

    De Bruycker Manolito

    2017-01-01

    Full Text Available Purpose: This meta-analysis evaluates the mid- to long-term survival outcome of MAT (meniscal allograft transplantation. Potential prognosticators, with particular focus on chondral status and age of the patient at the time of transplantation, were also analysed. Study design: Meta-analysis. Methods: An online database search was performed using following search string: “meniscal allograft transplantation” and “outcome”. A total of 65 articles were analysed for a total of 3157 performed MAT with a mean follow-up of 5.4 years. Subjective and clinical data was analysed. Results: The subjective and objective results of 2977 patients (3157 allografts were analysed; 70% were male, 30% were female. Thirty-eight percent received an isolated MAT. All other patients underwent at least one concomitant procedure. Lysholm, Knee injury and Osteoarthritis Outcome (KOOS, International Knee Documentation Committee (IKDC and Visual Analogue Scale (VAS scores were analysed. All scores showed a good patient satisfaction at long-term follow-up. The mean overall survival rate was 80.9%. Complication rates were comparable to standard meniscal repair surgery. There was a degenerative evolution in osteoarthritis with at least one grade in 1760 radiographically analysed patients. Concomitant procedures seem to have no effect on the outcome. Age at transplantation is a negative prognosticator. The body mass index (BMI of the patient shows a slightly negative correlation with the outcome of MAT. Conclusions: MAT is a viable solution for the younger patient with chronic pain in the meniscectomised knee joint. The complications are not severe and comparable to meniscal repair. The overall failure rate at final follow-up is acceptable and the allograft heals well in most cases, but MAT cannot be seen as a definitive solution for post-meniscectomy pain. The correct approach to the chronic painful total meniscectomised knee joint thus requires consideration of all

  15. Arthroscopic Meniscal Allograft Transplantation With Soft-Tissue Fixation Through Bone Tunnels.

    Science.gov (United States)

    Spalding, Tim; Parkinson, Ben; Smith, Nick A; Verdonk, Peter

    2015-10-01

    Meniscal allograft transplantation improves clinical outcomes for patients with symptomatic meniscus-deficient knees. We describe an established arthroscopic technique for meniscal allograft transplantation without the need for bone fixation of the meniscal horns. After preparation of the meniscal bed, the meniscus is parachuted into the knee through a silicone cannula and the meniscal horns are fixed with sutures through bone tunnels. The body of the meniscus is then fixed with a combination of all-inside and inside-out sutures. This technique is reliable and reproducible and has clinical outcomes comparable with those of bone plug fixation techniques.

  16. Meniscal Allograft Transplantation: State of the Art.

    Science.gov (United States)

    Trentacosta, Natasha; Graham, William C; Gersoff, Wayne K

    2016-06-01

    Meniscal allograft transplantation has evolved over the years to provide a state-of-the-art technique for the sports medicine surgeon to utilize in preserving contact mechanics and function of the knee in irreparable meniscal pathology. However, this procedure continues to spark considerable debate on proper tissue processing techniques, acceptable indications, methods of implantation, and potential long-term outcomes.

  17. Role of MRI in predicting meniscal tear reparability

    Energy Technology Data Exchange (ETDEWEB)

    Felisaz, Paolo Florent [Universita degli Studi di Pavia, Pavia (Italy); Fondazione IRCCS Policlinico San Matteo, Istituto di Radiologia, Pavia (Italy); Alessandrino, Francesco; Perelli, Simone [Universita degli Studi di Pavia, Pavia (Italy); Zanon, Giacomo; Benazzo, Francesco [Fondazione IRCCS Policlinico San Matteo, Clinica Ortopedica e Traumatologica, Pavia (Italy); Calliada, Fabrizio; Sammarchi, Luigi [Fondazione IRCCS Policlinico San Matteo Radiologia, Diagnostica per Immagini-Istituto di Radiologia, Pavia (Italy)

    2017-10-15

    To elucidate the role of MRI in predicting meniscal tear reparability according to tear type and location in relation to vascular zones. In this retrospective study, two readers evaluated 79 pre-surgical MRIs of meniscal tears arthroscopically treated with meniscectomy or meniscal repair. Tears were classified according to type into vertical, horizontal, radial, complex, flaps and bucket handle and were considered reparable if the distance measured from the tear to the menisco-capsular junction was less than or equal to 5 mm. Predictions were compared with the surgical procedure performed in arthroscopy. We assessed the diagnostic performance of MRI, agreement between MRI and arthroscopy, and interrater agreement. Then, we conducted an ROC analysis on the distances measured by the first reader and built a multivariate logistic regression model. MRI had a sensitivity, specificity, PPV, NPV and accuracy, respectively, of 85%, 79%, 86%, 76% and 83% in predicting meniscal tear reparability. Correct predictions for the specific tear pattern were 76% for vertical, 84% for horizontal, 88% for radial, 86% for complex, 84% for flaps and 86% for bucket handle. Agreement between the two readers' predictions and arthroscopy was good (k = 0.65 and 0.61, respectively). Inter-rater agreement was almost excellent (k = 0.79). The ROC analysis revealed sensitivity and specificity of 73% and 83% with a cutoff value of <4 mm (p < 0.001). Anterior cruciate ligament injury and medial meniscal tear increased the likelihood of meniscal tear reparability. MRI can be a reliable and accurate tool to predict the reparability of meniscal tears, with higher prediction rates for bucket-handle tears. (orig.)

  18. The knee meniscus: structure-function, pathophysiology, current repair techniques, and prospects for regeneration

    Science.gov (United States)

    Makris, Eleftherios A.; Hadidi, Pasha; Athanasiou, Kyriacos A.

    2011-01-01

    Extensive scientific investigations in recent decades have established the anatomical, biomechanical, and functional importance that the meniscus holds within the knee joint. As a vital part of the joint, it acts to prevent the deterioration and degeneration of articular cartilage, and the onset and development of osteoarthritis. For this reason, research into meniscus repair has been the recipient of particular interest from the orthopedic and bioengineering communities. Current repair techniques are only effective in treating lesions located in the peripheral vascularized region of the meniscus. Healing lesions found in the inner avascular region, which functions under a highly demanding mechanical environment, is considered to be a significant challenge. An adequate treatment approach has yet to be established, though many attempts have been undertaken. The current primary method for treatment is partial meniscectomy, which commonly results in the progressive development of osteoarthritis. This drawback has shifted research interest towards the fields of biomaterials and bioengineering, where it is hoped that meniscal deterioration can be tackled with the help of tissue engineering. So far, different approaches and strategies have contributed to the in vitro generation of meniscus constructs, which are capable of restoring meniscal lesions to some extent, both functionally as well as anatomically. The selection of the appropriate cell source (autologous, allogeneic, or xenogeneic cells, or stem cells) is undoubtedly regarded as key to successful meniscal tissue engineering. Furthermore, a large variation of scaffolds for tissue engineering have been proposed and produced in experimental and clinical studies, although a few problems with these (e.g., byproducts of degradation, stress shielding) have shifted research interest towards new strategies (e.g., scaffoldless approaches, self-assembly). A large number of different chemical (e.g., TGF-β1, C-ABC) and

  19. Weightbearing Versus Nonweightbearing After Meniscus Repair.

    Science.gov (United States)

    VanderHave, Kelly L; Perkins, Crystal; Le, Michael

    2015-01-01

    Optimal rehabilitation after meniscal repair remains controversial. To review the current literature on weightbearing status after meniscal repairs and to provide evidence-based recommendations for postoperative rehabilitation. MEDLINE (January 1, 1993 to July 1, 2014) and Embase (January 1, 1993 to July 1, 2014) were queried with use of the terms meniscus OR/AND repair AND rehabilitation. Included studies were those with levels of evidence 1 through 4, with minimum 2 years follow-up and in an English publication. Systematic review. Level 4. Demographics and clinical and radiographic outcomes of meniscus repair at a minimum of 2 years follow-up were extracted. Successful clinical outcomes ranged from 70% to 94% with conservative rehabilitation. More recent studies using an accelerated rehabilitation protocol with full weightbearing and early range of motion reported 64% to 96% good results. Outcomes after both conservative (restricted weightbearing) protocols and accelerated rehabilitation (immediate weightbearing) yielded similar good to excellent results; however, lack of similar objective criteria and consistency among surgical techniques and existing studies makes direct comparison difficult. © 2015 The Author(s).

  20. The role of biomaterials in the treatment of meniscal tears

    Directory of Open Access Journals (Sweden)

    Crystal O. Kean

    2017-11-01

    Full Text Available Extensive investigations over the recent decades have established the anatomical, biomechanical and functional importance of the meniscus in the knee joint. As a functioning part of the joint, it serves to prevent the deterioration of articular cartilage and subsequent osteoarthritis. To this end, meniscus repair and regeneration is of particular interest from the biomaterial, bioengineering and orthopaedic research community. Even though meniscal research is previously of a considerable volume, the research community with evolving material science, biology and medical advances are all pushing toward emerging novel solutions and approaches to the successful treatment of meniscal difficulties. This review presents a tactical evaluation of the latest biomaterials, experiments to simulate meniscal tears and the state-of-the-art materials and strategies currently used to treat tears.

  1. Magnetic resonance imaging of meniscal bucket-handle tears

    International Nuclear Information System (INIS)

    Dfouni, N.; Garcia, J.; Kindynis, Ph.; Bosson, D.

    1997-01-01

    To define MR signs of meniscal bucket-handle tears and evaluate the diagnostic efficiency of this technique. Retrospective study of 30 patients with a meniscal bucket-handle tear and 30 with a different type of tear, all proven by arthroscopy. The following MR signs of a bucket-handle tear were evaluated: 'separate meniscal fragment, 'double posterior cruciate ligament', 'snake sign' and 'double anterior horn'. A correct diagnosis of a bucket-handle tear was only made in 18/30 of patients. Several of the MR signs were seen in the same patient in 17 cases. A double posterior cruciate ligament was present only in cases of medial meniscus tears. The 12 menisci without these signs, and therefore not diagnosed as bucket-handle tears, were all classified as meniscal tears on the basis of signal extending to the meniscal surface. Nine of these were not displaced into the inter-condylar notch at arthroscopy. The interobserver agreement was excellent: kappa 0.88. The diagnosis of a bucket-handle meniscal tear, if it is displaced, can be made when one or more of the four MR evaluated signs are present. Other forms of meniscal tears are only exceptionally diagnosed as bucket-handle tears. (authors)

  2. Proximity of the Triangular Fibrocartilage Complex to Key Surrounding Structures and Safety Assessment of an Arthroscopic Repair Technique: A Cadaveric Study.

    Science.gov (United States)

    Kuremsky, Marshall A; Habet, Nahir; Peindl, Richard D; Gaston, R Glenn

    2016-12-01

    To quantify the distance of the dorsal ulnar sensory branch, floor of the extensor carpi ulnaris (ECU) subsheath, and ulnar neurovascular bundles from the triangular fibrocartilage complex (TFCC), and secondarily to assess the safety of an all-inside arthroscopic repair of the TFCC with a commonly used meniscal repair device with respect to the aforementioned structures. A custom K-wire with 1-mm gradation was used to determine the distance of at-risk structures from the periphery of the TFCC in 13 above-elbow human cadaver specimens. An all-inside repair of the TFCC at the location of a Palmer 1B tear was then performed using a commonly employed meniscal repair device. The distance from the deployed devices to the structure in closest proximity was then measured using digital calipers. The mean distance from the deployed device to the nearest structure of concern for iatrogenic injury was 9.4 mm (range, 5-15 mm). The closest structure to iatrogenic injury was usually, but not always, the dorsal ulnar sensory nerve in 9 of 13 wrists (69.2%) at 9.3 mm (range, 5-15 mm); on 3 occasions it was instead the ulnar nerve (23.1%) at 9.5 mm (range, 9-10 mm), and on 1 occasion 6 mm from the flexor digitorum profundus to the little finger (7.7%). Forearm rotation had no significant effect on measured distances (ulnar nerve: P = .98; dorsal sensory: P = .89; ECU: P = .90). The largest influence of forearm rotation was a 0.4-mm difference between pronation and supination with respect to the distance of the TFCC periphery on the ECU subsheath. An all-inside arthroscopic TFCC repair using a commonly used meniscal repair device appears safe with respect to nearby neurovascular structures and tendons under typical arthroscopic conditions. An all-inside arthroscopic TFCC repair using a commonly employed meniscal repair device appears safe in terms of proximity to important structures although further clinical investigation is warranted. Copyright © 2016 Arthroscopy

  3. Bucket handle tears of the medial meniscus: meniscal intrusion rather than meniscal extrusion

    International Nuclear Information System (INIS)

    Schlossberg, S.; Umans, H.; Flusser, G.; DiFelice, G.S.; Lerer, D.B.

    2007-01-01

    To determine the frequency of medial meniscal extrusion (MME) versus ''medial meniscal intrusion'' in the setting of bucket handle tears. Images were evaluated for previously reported risk factors for MME, including: medial meniscal root tear, radial tear, degenerative joint disease and joint effusion. Forty-one consecutive cases of bucket handle tear of the medial meniscus were reviewed by consensus by two musculoskeletal radiologists. Imaging was performed using a 1.5 GE Signa MR unit. Patient age, gender, medial meniscal root integrity, MME, medial meniscal intrusion, degenerative joint disease, effusion and anterior cruciate ligament (ACL) tear were recorded. Thirteen females and 27 males (age 12-62 years, median=30 years) were affected; one had bucket handle tear of each knee. Effusion was small in 13, moderate in 9 and large in 18. Degenerative joint disease was mild in three, moderate in two and severe in one. 26 ACL tears included three partial and three chronic. Medial meniscal root tear was complete in one case and partial thickness in two. None of the 40 cases with an intact or partially torn medial meniscal root demonstrated MME. MME of 3.1 mm was seen in the only full-thickness medial meniscal root tear, along with chronic ACL tear, moderate degenerative joint disease and large effusion. Medial meniscal intrusion of the central bucket handle fragment into the intercondylar notch was present in all 41 cases. Given an intact medial meniscal root in the setting of a ''pure'' bucket handle tear, there is no MME. (orig.)

  4. Cell-Based Meniscal Repair Using an Aligned Bioactive Nanofibrous Sheath

    Science.gov (United States)

    2016-07-01

    Engineering . Overlap: None Title: “Development of Novel Bioartificial Ligament Using Autologous Biological Scaffold and Cells” Grant#: W81XWH-13-2-0030...patient to rapid joint degeneration (i.e., osteoarthritis). Tissue engineering approaches, including the combination of cells, scaffolds, and...electrospun nano/microfibers comprising engineered scaffolds can mimic the ultrastructure of the native meniscal extracellular matrix (ECM); when seeded with

  5. Repair of Avascular Meniscus Tears with Electrospun Collagen Scaffolds Seeded with Human Cells.

    Science.gov (United States)

    Baek, Jihye; Sovani, Sujata; Glembotski, Nicholas E; Du, Jiang; Jin, Sungho; Grogan, Shawn P; D'Lima, Darryl D

    2016-03-01

    The self-healing capacity of an injured meniscus is limited to the vascularized regions and is especially challenging in the inner avascular regions. As such, we investigated the use of human meniscus cell-seeded electrospun (ES) collagen type I scaffolds to produce meniscal tissue and explored whether these cell-seeded scaffolds can be implanted to repair defects created in meniscal avascular tissue explants. Human meniscal cells (derived from vascular and avascular meniscal tissue) were seeded on ES scaffolds and cultured. Constructs were evaluated for cell viability, gene expression, and mechanical properties. To determine potential for repair of meniscal defects, human meniscus avascular cells were seeded and cultured on aligned ES collagen scaffolds for 4 weeks before implantation. Surgical defects resembling "longitudinal tears" were created in the avascular zone of bovine meniscus and implanted with cell-seeded collagen scaffolds and cultured for 3 weeks. Tissue regeneration and integration were evaluated by histology, immunohistochemistry, mechanical testing, and magentic resonance imaging. Ex vivo implantation with cell-seeded collagen scaffolds resulted in neotissue that was significantly better integrated with the native tissue than acellular collagen scaffolds or untreated defects. Human meniscal cell-seeded ES collagen scaffolds may therefore be useful in facilitating meniscal repair of avascular meniscus tears.

  6. Meniscal tissue regeneration in porous 50/50 copoly(L-lactide/epsilon-caprolactone) implants

    NARCIS (Netherlands)

    de Groot, J. H.; Zijlstra, F. M.; Kuipers, HW; Pennings, A. J.; Veth, RPH; Jansen, HWB

    Porous materials of a high-molecular-weight 50/50 copolymer of L-lactide and epsilon-caprolactone with different compression moduli were used for meniscal repair. In contrast to the previously used 4,4'-diphenylmethane and 1,6-trans-cyclohexane diisocyanates containing polyurethanes, degradation

  7. A new hydrogel for the conservative treatment of meniscal lesions: a randomized controlled study.

    Science.gov (United States)

    Zorzi, Claudio; Rigotti, Stefano; Screpis, Daniele; Giordan, Nicola; Piovan, Gianluca

    2015-01-01

    this study aimed to investigate the efficacy of intra-articular (IA) administration of a hydrogel formulation obtained from a hyaluronic acid (HA) derivative (HYADD4(®)) in the management of meniscal tears and in meniscal tear repair. fifty subjects with degenerative meniscal tears were enrolled into this single-site, observer-blind, parallel-group study. Clinical evaluations were performed at baseline and after 14, 30 and 60 days. Clinical outcomes included: pain reduction (Visual Analog Scale), improvement of knee functionality (WOMAC questionnaire), reduction in length and depth of the meniscal lesion (MRI-confirmed) and SF-36 questionnaire scores. Local tolerability and safety were also investigated. a significant reduction in VAS pain (p< 0.001) in favor of HYADD4(®) was recorded at day 14 and maintained at all the follow-up assessments. Data on knee functionality were in line with the VAS pain assessment results. A significant reduction in length and depth of the meniscal lesion, assessed using MRI, was found in the HYADD4(®) group compared to the control group (p<0.001). the results of this study may indicate a new treatment option in the conservative management of patients complaining of pain due to meniscal tears. The MRI data suggest that the hydrogel formulation of HA used in this study may also play a role in the healing process of the lesion. Level I, prospective randomized clinical trial.

  8. Tensile strength of the pullout repair technique for the medial meniscus posterior root tear: a porcine study.

    Science.gov (United States)

    Fujii, Masataka; Furumatsu, Takayuki; Xue, Haowei; Miyazawa, Shinichi; Kodama, Yuya; Hino, Tomohito; Kamatsuki, Yusuke; Ozaki, Toshifumi

    2017-10-01

    The purpose of this study was to compare the load-to-failure of different common suturing techniques with a new technique for the medial meniscus posterior root tear (MMPRT). Thirty porcine medial menisci were randomly assigned to three suturing techniques used for transtibial pullout repair of the MMPRT (n = 10 per group). Three different meniscal suture configurations were studied: the two simple suture (TSS) technique, the conventional modified Mason-Allen suture (MMA) technique, and the new MMA technique using the FasT-Fix combined with the Ultrabraid (F-MMA). The ultimate failure load was tested using a tensile testing machine. The MMA and F-MMA groups demonstrated significantly higher failure loads than the TSS group (P = 0.0003 and P = 0.0005, respectively). No significant differences were observed between the MMA and F-MMA groups (P = 0.734). The ultimate failure load was significantly greater in the F-MMA than the TSS group and similar to the conventional MMA technique.

  9. Biological knee reconstruction for combined malalignment, meniscal deficiency, and articular cartilage disease.

    Science.gov (United States)

    Harris, Joshua D; Hussey, Kristen; Wilson, Hillary; Pilz, Kyle; Gupta, Anil K; Gomoll, Andreas; Cole, Brian J

    2015-02-01

    The aim of this study was to analyze patient-reported outcomes in those undergoing the triad of simultaneous osteotomy, meniscal transplantation, and articular cartilage repair. Patients undergoing simultaneous meniscal transplantation, distal femoral or proximal tibial osteotomy, and articular cartilage surgery by a single surgeon (B.J.C.) were analyzed. Meniscal transplantation was performed using bone-in-slot techniques. Distal femoral and high tibial osteotomies were performed for valgus and varus malalignment, respectively. Microfracture, autologous chondrocyte implantation, and osteochondral autograft or allograft were performed for articular cartilage disease. Validated patient-reported and surgeon-measured outcomes were collected. Preoperative and postoperative outcomes and medial versus lateral disease were compared using Student t tests. Eighteen participants (mean age, 34 ± 7.8 years; symptomatic patients, 7.4 ± 5.6 years; 2.4 ± 1.0 surgical procedures before study enrollment; mean follow-up, 6.5 ± 3.2 years) were analyzed. Two thirds of participants had medial compartment pathologic conditions and one third had lateral compartment pathologic processes. At final follow-up, there were statistically significant clinically meaningful improvements in International Knee Documentation Committee (IKDC) subjective classification, Lysholm score, and 4 Knee Injury and Osteoarthritis Outcome Score (KOOS) subscores. Postoperative 12-item short form (SF-12) physical and mental component scores were not significantly different from preoperative scores. The Kellgren-Lawrence classification grade was 1.5 ± 1.1 at 2.5 ± 3.0 years after surgery. There was a significantly higher preoperative SF-12 physical composite score (PCS) in participants with lateral compartment pathologic conditions (v medial compartment conditions) (P = .011). Although there were 13 reoperations in 10 patients (55.5% reoperation rate), only one patient was converted to knee arthroplasty (5

  10. Lesão meniscal por fadiga Meniscal injury due to fatigue

    Directory of Open Access Journals (Sweden)

    Gilberto Luis Camanho

    2009-01-01

    Full Text Available OBJETIVO: O intuito do presente estudo é de analisar um grupo de pacientes portadores de lesão meniscal decorrente da falência estrutural sem relação com trauma ou problemas degenerativos, optando por chamá-la de lesão meniscal por fadiga. MATERIAL E MÉTODO: Foram avaliados 140 pacientes com lesão meniscal sem causa aparente e, portanto, considerados portadores da lesão meniscal por fadiga. Dentre eles, 85 pacientes eram do sexo masculino e 55 do sexo feminino. O menisco medial foi o mais acometido (92% dos casos. RESULTADOS: Todas as lesões foram diagnosticadas através de exame clínico e ressonância magnética. Os pacientes foram submetidos a meniscectomia por via artroscópica e os resultados foram divididos em dois tipos: bons e maus. Foram encontrados 27% de maus resultados dos quais nove pacientes evoluíram para osteonecrose idiopática. CONCLUSÃO: Concluímos que as lesões por fadiga devem ser analisadas como lesões provocadas por falência, portanto uma patologia sindrômica que pode evoluir para uma osteonecrose idiopática..OBJECTIVE: The purpose of the present study was to review a group of patients with meniscal injuries resulting from structural failure unrelated to trauma or degenerative problems to which was given the name "meniscal injury due to fatigue". MATERIAL AND METHOD: Evaluations were made on 140 patients with meniscal injuries without any apparent cause, who were therefore considered to have meniscal injuries due to fatigue. Among these, 85 patients were male and 55 were female. The medial meniscus was the most affected site (92% of the cases. RESULTS: All these injuries were diagnosed by means of clinical examination and magnetic resonance imaging. The patients underwent meniscectomy by means of arthroscopy and the results were divided into two types: good and poor. Poor results were found in 27% of the cases, among which nine patients progressed to idiopathic osteonecrosis. CONCLUSION: We conclude that

  11. Effective Treatment of an Apparent Meniscal Injury Using the Mulligan Concept

    Directory of Open Access Journals (Sweden)

    Alex J. Rhinehart

    2015-05-01

    Full Text Available Objective: Present a clinic case demonstrating the effectiveness of the Mulligan Concept (MC in treating an apparent meniscal injury. The utilization of the MC in the evaluation and treatment of a 20-year-old soccer player with an apparent acute meniscal injury is presented. Background: Meniscal injuries are common knee injuries. The MC is a therapeutic intervention strategy applied as both a treatment-based evaluation and therapeutic intervention. Treatment: The patient was successfully treated in four treatment sessions using the MC. The patient experienced minimal clinically-important differences on a variety of global and regional patient-rated outcomes. Uniqueness: To the author’s knowledge, there are currently no published case reports of using the MC in clinical practice to treat an apparent meniscal pathology. Conclusion: The MC can be utilized as an evaluation and treatment technique in patients suspected of having meniscal pathology in the knee.

  12. MRI of menisci repaired with bioabsorbable arrows

    International Nuclear Information System (INIS)

    Mustonen, Antti O.T.; Kiuru, Martti; Koskinen, Seppo K.; Tielinen, Laura; Lindahl, Jan; Hirvensalo, Eero

    2006-01-01

    To analyze with conventional magnetic resonance imaging (MRI) the signal appearance of menisci repaired with bioabsorbable arrows. Forty-four patients with 47 meniscal tears treated with bioabsorbable arrows underwent follow-up conventional MRI examination. The time interval between the surgery and MRI varied from 5 to 67 months (mean 26 months). Twenty-six patients also had concurrent repair of torn anterior cruciate ligament. The following grades were used to classify meniscal signal intensity: (a) G0; low signal intensity on all sequences and regular configuration in every plane, (b) G1; increased signal intensity within the meniscus, not extending to the meniscal surface, (c) G2; increased signal intensity linear in shape, which may or may not communicate with the capsular margin of the meniscus, without extending to the meniscal surface, and (d) G3; increased signal intensity extending to the meniscal surface. Thirteen menisci (27.5%) had normal signal intensity, 13 menisci (27.5%) Grade 1 signal intensity, 9 menisci (19%) Grade 2 signal intensity and 12 menisci (26%) Grade 3 signal intensity. The time difference between operation and MRI was statistically significant between the G0 (36 months) and G3 groups (14 months; P=0.0288). There was no statistical significance in different grades between medial and lateral meniscus or between patients with operated or intact ACL. On physical examination sixteen patients reported slight symptoms, seen evenly in each group. (orig.)

  13. Quantifying peri-meniscal synovitis and its relationship to meniscal pathology in osteoarthritis of the knee

    Energy Technology Data Exchange (ETDEWEB)

    Grainger, Andrew J. [Leeds General Infirmary, Department of Radiology, Leeds (United Kingdom); Rhodes, Laura A. [Leeds General Infirmary, Academic Unit of Medical Physics, The University of Leeds, Leeds (United Kingdom); Keenan, Anne-Maree; Emery, Paul; Conaghan, Philip G. [Leeds General Infirmary, Academic Unit of Musculoskeletal Disease, Leeds (United Kingdom)

    2007-01-15

    The objectives of this study were to validate a semiquantitative scoring system for estimating perimeniscal synovitis in osteoarthritic (OA) knees and to examine the relationship between the extent of synovitis and the degree of meniscal pathology using gadolinium-enhanced magnetic resonance imaging (MRI). Forty-three subjects with clinically diagnosed OA knee were assessed for peri-meniscal synovitis using gadolinium-enhanced MRI. Quantitative measurements of synovitis were made by summing areas in consecutive slices within generated regions of interest, and the synovitis was also scored semi-quantitatively using a 0-3 scale. Meniscal pathology (extrusion, degeneration and tearing) was also scored semiquantitatively. Establishment of a correlative relationship was undertaken using Spearman's rho ({rho}). A total of 86 sites were assessed. The semi-quantitative synovitis score correlated well with the quantitative synovitis score ({rho}>0.9). A moderate association between medial meniscal extrusion and synovitis was demonstrated ({rho}=0.762, P<0.000), although this association was not as strong in the lateral compartment ({rho}=0.524, P<0.000). The results suggest the semiquantitative scoring system is valid for assessing perimeniscal synovitis. The relationship between meniscal pathology and adjacent synovitis requires further study. (orig.)

  14. [SPECIFIC DIAGNOSTIC SIGNIFICANCE OF "RIPPLE SIGN" OF MEDIAL FEMORAL CONDYLE UNDER ARTHROSCOPE IN MEDIAL LONGITUDINAL MENISCAL TEARS].

    Science.gov (United States)

    Ren Shiyou; Sun, Limang; Chen, Guofei; Jiang, Changqing; Zhang, Xintao; Zhang Wentao

    2015-01-01

    To investigate the reliability of the "ripple sign" on the upper surface of the medial femoral condyle in the diagnosis of medial longitudinal meniscal tears under arthroscope. Between June 2013 and June 2014, 56 patients with knee injuries were included. There were 35 males and 21 females with an average age of 22.2 years (range, 12-38 years). The causes of injury were sports in 40 cases, falling in 10 cases, and traffic accident in 6 cases. The injury was located at the left knee in 22 cases and at the right knee in 34 cases. The disease duration was 10-40 days (mean, 20.2 days). Of 56 patients, 15 cases had simple medial meniscal injury; 41 cases had combined injuries, including anterior cruciate ligament injury in 38 cases, posterior cruciate ligament injury in 2 cases, and patellar dislocation in 1 case. The "ripple sign" was observed under arthroscope before operation. Repair of medial meniscal injury and reconstruction of cruciate ligament were performed. The positive "ripple sign" was seen under arthroscope in all patients, who were diagnosed to have longitudinal meniscal tears, including 23 cases of mild "ripple sign" , 28 cases of moderate "ripple sign", and 5 cases of severe "ripple sign". The "ripple sign" on the upper surface of the medial femoral condyle is a reliable diagnostic evidence of medial longitudinal meniscal tears.

  15. MR imaging of meniscal subluxation in the knee

    International Nuclear Information System (INIS)

    Breitenseher, M.J.; Tratting, S.; Dobrocky, I.; Steiner, E.; Imhof, H.; Kukla, C.; Nehrer, S.

    1997-01-01

    Purpose: The aim of this study was to establish diagnostic criteria for meniscal subluxation, and to determine whether there was any connection between meniscal subluxation and other common meniscal and knee-joint abnormalities. Material and Methods: The normal position of the meniscal body was assessed in 10 asymptomatic volunteers. MR signs of meniscal subluxation were evaluated retrospectively in 60 symptomatic patients with pain the knee, impaired mobility, and/or joint swelling who had no clear diagnosis after the evaluation of case history, clinical examination, and radiography. The criterion for subluxation of the meniscus was defined as a distance of ≥3 mm between the peripheral border of the meniscus and the edge of the tibial plateau. Results: In the volunteers, the mean distance form the medial meniscus to the edge of the tibial plateau was 0.07 mm, and that from the lateral meniscus was 0 mm. In 55 symptomatic patients without meniscal subluxation, the mean distance from the meniscus to the edge of the tribial plateau was 0.27 mm. Five patients (8%) had evidence of meniscal subluxation, 4 in the medial meniscus and one in the lateral meniscus. The most commonly associated knee abnormality was joint effusion in 5 knees and osteoarthritis in 2 knees. Conclusion: Meniscal subluxation was not a rare finding with MR imaging in patients with painful knees. Meniscal subluxation was associated with other knee abnormalities such as joint effusion or osteoarthritis. (orig.)

  16. MRI of displaced meniscal fragments

    International Nuclear Information System (INIS)

    Dunoski, Brian; Zbojniewicz, Andrew M.; Laor, Tal

    2012-01-01

    A torn meniscus frequently requires surgical fixation or debridement as definitive treatment. Meniscal tears with associated fragment displacement, such as bucket handle and flap tears, can be difficult to recognize and accurately describe on MRI, and displaced fragments can be challenging to identify at surgery. A displaced meniscal fragment can be obscured by synovium or be in a location not usually evaluated at arthroscopy. We present a pictorial essay of meniscal tears with displaced fragments in patients referred to a pediatric hospital in order to increase recognition and accurate interpretation by the radiologist, who in turn can help assist the surgeon in planning appropriate therapy. (orig.)

  17. MRI of displaced meniscal fragments

    Energy Technology Data Exchange (ETDEWEB)

    Dunoski, Brian [University of Cincinnati College of Medicine, Department of Radiology, Cincinnati Children' s Hospital Medical Center, Cincinnati, OH (United States); Children' s Hospital of Michigan, Department of Radiology, Detroit, MI (United States); Zbojniewicz, Andrew M.; Laor, Tal [University of Cincinnati College of Medicine, Department of Radiology, Cincinnati Children' s Hospital Medical Center, Cincinnati, OH (United States)

    2012-01-15

    A torn meniscus frequently requires surgical fixation or debridement as definitive treatment. Meniscal tears with associated fragment displacement, such as bucket handle and flap tears, can be difficult to recognize and accurately describe on MRI, and displaced fragments can be challenging to identify at surgery. A displaced meniscal fragment can be obscured by synovium or be in a location not usually evaluated at arthroscopy. We present a pictorial essay of meniscal tears with displaced fragments in patients referred to a pediatric hospital in order to increase recognition and accurate interpretation by the radiologist, who in turn can help assist the surgeon in planning appropriate therapy. (orig.)

  18. Detecting meniscal tears in primary care

    NARCIS (Netherlands)

    Snoeker, B.A.M.

    2017-01-01

    Although meniscal tears are a very common phenomenon uncertainty exists about the diagnosis and treatment of meniscal tears in primary care. This thesis aims to provide evidence for general practitioners and physical therapists regarding the diagnosis and management of patients with a suspected

  19. MRI of meniscal bucket-handle tears

    Energy Technology Data Exchange (ETDEWEB)

    Magee, T.H.; Hinson, G.W. [Menorah Medical Center, Overland Park, KS (United States). Dept. of Radiology

    1998-09-01

    A meniscal bucket-handle tear is a tear with an attached fragment displaced from the meniscus of the knee joint. Low sensitivity of MRI for detection of bucket-handle tears (64% as compared with arthroscopy) has been reported previously. We report increased sensitivity for detecting bucket-handle tears with the use of coronal short tau inversion recovery (STIR) images. Results. By using four criteria for diagnosis of meniscal bucket-handle tears, our overall sensitivity compared with arthroscopy was 93% (28 of 30 meniscal bucket-handle tears seen at arthroscopy were detected by MRI). The meniscal fragment was well visualized in all 28 cases on coronal STIR images. The double posterior cruciate ligament sign was seen in 8 of 30 cases, the flipped meniscus was seen in 10 of 30 cases and a fragment in the intercondylar notch was seen in 18 of 30 cases. (orig.)

  20. Advances and Prospects in Tissue-Engineered Meniscal Scaffolds for Meniscus Regeneration

    Directory of Open Access Journals (Sweden)

    Weimin Guo

    2015-01-01

    Full Text Available The meniscus plays a crucial role in maintaining knee joint homoeostasis. Meniscal lesions are relatively common in the knee joint and are typically categorized into various types. However, it is difficult for inner avascular meniscal lesions to self-heal. Untreated meniscal lesions lead to meniscal extrusions in the long-term and gradually trigger the development of knee osteoarthritis (OA. The relationship between meniscal lesions and knee OA is complex. Partial meniscectomy, which is the primary method to treat a meniscal injury, only relieves short-term pain; however, it does not prevent the development of knee OA. Similarly, other current therapeutic strategies have intrinsic limitations in clinical practice. Tissue engineering technology will probably address this challenge by reconstructing a meniscus possessing an integrated configuration with competent biomechanical capacity. This review describes normal structure and biomechanical characteristics of the meniscus, discusses the relationship between meniscal lesions and knee OA, and summarizes the classifications and corresponding treatment strategies for meniscal lesions to understand meniscal regeneration from physiological and pathological perspectives. Last, we present current advances in meniscal scaffolds and provide a number of prospects that will potentially benefit the development of meniscal regeneration methods.

  1. New understanding of the complex structure of knee menisci: implications for injury risk and repair potential for athletes.

    Science.gov (United States)

    Rattner, J B; Matyas, J R; Barclay, L; Holowaychuk, S; Sciore, P; Lo, I K Y; Shrive, N G; Frank, C B; Achari, Y; Hart, D A

    2011-08-01

    Menisci help maintain the structural integrity of the knee. However, the poor healing potential of the meniscus following a knee injury can not only end a career in sports but lead to osteoarthritis later in life. Complete understanding of meniscal structure is essential for evaluating its risk for injury and subsequent successful repair. This study used novel approaches to elucidate meniscal architecture. The radial and circumferential collagen fibrils in the meniscus were investigated using novel tissue-preparative techniques for light and electron microscopic studies. The results demonstrate a unique architecture based on differences in the packaging of the fundamental collagen fibrils. For radial arrays, the collagen fibrils are arranged in parallel into ∼10 μm bundles, which associate laterally to form flat sheets of varying dimensions that bifurcate and come together to form a honeycomb network within the body of the meniscus. In contrast, the circumferential arrays display a complex network of collagen fibrils arranged into ∼5 μm bundles. Interestingly, both types of architectural organization of collagen fibrils in meniscus are conserved across mammalian species and are age and sex independent. These findings imply that disruptions in meniscal architecture following an injury contribute to poor prognosis for functional repair. © 2010 John Wiley & Sons A/S.

  2. MR imaging of meniscal tears: correlation with history of trauma

    International Nuclear Information System (INIS)

    Choi, Jong Cheul; Yang, Seoung Oh; Choi, Sun Seob; Son, Seok Hyun; Lee, Yung Il; Chung, Duck Hwan; Kim, Kyung Taek; Sohn, Sung Keun; Lee, Jung Yoon

    1994-01-01

    The medial meniscus is injured much more than the lateral meniscus. Because the medial meniscus is much larger in diameter, is thinner in its periphery and narrower in body than the lateral meniscus, and dose not attach to either cruciate ligament. We evaluated correlations with sites of tear and history of trauma. We reviewed retrospectively in 43 patients with meniscal tears on MR(51 cases) and correlated them with history of trauma. The most common site of injury was the posterior horn of the medial meniscuc(32/51), but high incidence of lateral meniscal tear compared with previous reports was seen. In the cases which had history of trauma, the posterior horn of medial meniscus was most commonly injured(26/34) and 5 meniscal tears were combined with meniscal tear in the other site. The tear in the anterior horn of the medial meniscus was seen only in a patient which had history of trauma and combined with meniscal tear in the other site. But in the meniscal tears without definite history of trauma, the incidence of meniscal tear was different from the meniscal tear with history of trauma. The incidence of lateral meniscal tear(11/17) was higher than medial meniscal tear and the posterior horn of lateral meniscus was commonly injured. We concluded that the medial meniscus was commonly injured, especially posterior horn, but in the cases which had no definite history of trauma, the lateral meniscus was commonly injured. An awareness of prevalent site of meniscal injuries may be helpful in the diagnostic interpretation of MR imaging of knee

  3. Utility of three-dimensional method for diagnosing meniscal lesions

    International Nuclear Information System (INIS)

    Ohshima, Suguru; Nomura, Kazutoshi; Hirano, Mako; Hashimoto, Noburo; Fukumoto, Tetsuya; Katahira, Kazuhiro

    1998-01-01

    MRI of the knee is a useful method for diagnosing meniscal tears. Although the spin echo method is usually used for diagnosing meniscal tears, we examined the utility of thin slice scan with the three-dimensional method. We reviewed 70 menisci in which arthroscopic findings were confirmed. In this series, sensitivity was 90.9% for medial meniscal injuries and 68.8% for lateral meniscal injuries. There were 3 meniscal tears in which we could not detect tears on preoperative MRI. We could find tears in two of these cases when re-evaluated using the same MRI. In conclusion, we can get the same diagnostic rate with the three-dimensional method compared with the spin echo method. Scan time of the three-dimensional method is 3 minutes, on the other hand that of spin echo method in 17 minutes. This slice scan with three-dimensional method is useful for screening meniscal injuries before arthroscopy. (author)

  4. Diagnostic value of self-reported mechanical symptoms for diagnosing large meniscal tears in patients aged 40 years or older with meniscal tears

    DEFF Research Database (Denmark)

    Pihl, Kenneth; Englund, Martin; Lohmander, Stefan

    2017-01-01

    Purpose: Meniscal tears, which are longitudinal-vertical tears (e.g. bucket-handle tears) and/or involve all three meniscal sub regions (anterior horn, body and posterior horn), are typically large and assumed to cause patient perceived mechanical knee symptoms (knee grinding or clicking and knee...... catching or locking). However, whether the presence of such mechanical symptoms is useful for diagnosing these forms of meniscus tears is unknown. Therefore, we investigated the diagnostic values of having mechanical symptoms in diagnosing a bucket-handle tear and/or a tear involving all three meniscal sub...... regions in middle-aged and older patients undergoing arthroscopic meniscal surgery. Methods: This study is a secondary analysis of Pihl et al. OARSI 2017. The study included patients aged 40 years or older undergoing surgery for a meniscal tear from Knee Arthroscopy Cohort Southern Denmark (KACS...

  5. Part II: Biomechanical assessment for a footprint-restoring transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique.

    Science.gov (United States)

    Park, Maxwell C; Tibone, James E; ElAttrache, Neal S; Ahmad, Christopher S; Jun, Bong-Jae; Lee, Thay Q

    2007-01-01

    We hypothesized that a transosseous-equivalent repair would demonstrate improved tensile strength and gap formation between the tendon and tuberosity when compared with a double-row technique. In 6 fresh-frozen human shoulders, a transosseous-equivalent rotator cuff repair was performed: a suture limb from each of two medial anchors was bridged over the tendon and fixed laterally with an interference screw. In 6 contralateral matched-pair specimens, a double-row repair was performed. For all repairs, a materials testing machine was used to load each repair cyclically from 10 N to 180 N for 30 cycles; each repair underwent tensile testing to measure failure loads at a deformation rate of 1 mm/sec. Gap formation between the tendon edge and insertion was measured with a video digitizing system. The mean ultimate load to failure was significantly greater for the transosseous-equivalent technique (443.0 +/- 87.8 N) compared with the double-row technique (299.2 +/- 52.5 N) (P = .043). Gap formation during cyclic loading was not significantly different between the transosseous-equivalent and double-row techniques, with mean values of 3.74 +/- 1.51 mm and 3.79 +/- 0.68 mm, respectively (P = .95). Stiffness for all cycles was not statistically different between the two constructs (P > .40). The transosseous-equivalent rotator cuff repair technique improves ultimate failure loads when compared with a double-row technique. Gap formation is similar for both techniques. A transosseous-equivalent repair helps restore footprint dimensions and provides a stronger repair than the double-row technique, which may help optimize healing biology.

  6. Meniscal shear stress for punching.

    Science.gov (United States)

    Tuijthof, Gabrielle J M; Meulman, Hubert N; Herder, Just L; van Dijk, C Niek

    2009-01-01

    Experimental determination of the shear stress for punching meniscal tissue. Meniscectomy (surgical treatment of a lesion of one of the menisci) is the most frequently performed arthroscopic procedure. The performance of a meniscectomy is not optimal with the currently available instruments. To design new instruments, the punching force of meniscal tissue is an important parameter. Quantitative data are unavailable. The meniscal punching process was simulated by pushing a rod through meniscal tissue at constant speed. Three punching rods were tested: a solid rod of Oslash; 3.00 mm, and two hollow tubes (Oslash; 3.00-2.60 mm) with sharpened cutting edges of 0.15 mm and 0.125 mm thick, respectively. Nineteen menisci acquired from 10 human cadaveric knee joints were punched (30 tests). The force and displacement were recorded from which the maximum shear stress was determined (average added with three times the standard deviation). The maximum shear stress for the solid rod was determined at 10.2 N/mm2. This rod required a significantly lower punch force in comparison with the hollow tube having a 0.15 mm cutting edge (plt;0.01). The maximum shear stress for punching can be applied to design instruments, and virtual reality training environments. This type of experiment is suitable to form a database with material properties of human tissue similar to databases for the manufacturing industry.

  7. Arthroscopic Hip Labral Repair: The Iberian Suture Technique

    OpenAIRE

    Stubbs, Allston J.; Andersen, Jason S.; Mannava, Sandeep; Wooster, Benjamin M.; Howse, Elizabeth A.; Winter, S. Bradley

    2014-01-01

    Arthroscopic hip labral repair has beneficial short-term outcomes; however, debate exists regarding ideal surgical labral repair technique. This technical note presents an arthroscopic repair technique that uses intrasubstance labral suture passage to restore the chondrolabral interface. This “Iberian suture technique” allows for an anatomic repair while posing minimal risk of damage to the labral and chondral tissues.

  8. PCL tibial avulsion with an associated medial meniscal tear in a child: a case report on diagnosis and management.

    LENUS (Irish Health Repository)

    2012-02-01

    Posterior cruciate ligament (PCL) injuries from tibial avulsions are rare in the paediatric setting. One would need a high index of suspicion as clinical examination may be difficult, especially in the early period. Magnetic resonance imaging is an excellent diagnostic modality for this condition and other associated injuries within the knee. We report a rare case in which the patient had a PCL avulsion off the tibial insertion site with an associated posterior horn medial meniscal tear off the posterior capsule. He was treated through open reduction and internal fixation of the avulsed fragment with suture repair of the meniscal tear. We emphasize the importance of diagnosing and managing associated intra-articular injuries when dealing with the rare condition of PCL tibial avulsion in the paediatric setting.

  9. Posterior horn medial meniscal root tear: the prequel

    Energy Technology Data Exchange (ETDEWEB)

    Umans, H. [Albert Einstein College of Medicine, Bronx, NY (United States); Lenox Hill Radiology and Imaging Associates, New York, NY (United States); Morrison, W. [Thomas Jefferson University Hospital, Philadelphia, PA (United States); DiFelice, G.S. [Hospital for Special Surgery, New York, NY (United States); Vaidya, N. [Crystal Run Healthcare, Middletown, NY (United States); Winalski, C.S. [Cleveland Clinic, Imaging Institute, Department of Biomedical Engineering, Lerner Research Institute, Cleveland, OH (United States)

    2014-06-15

    To determine whether subarticular marrow changes deep to the posterior horn medial meniscal root anchor might predict subsequent medial meniscal root tear. Fifteen patients with MR-diagnosed posterior horn medial meniscal root (PHMMR) tear and a knee MRI antecedent to the tear were identified at three imaging centers over a 7-year period. The pre- and post-tear MR images were evaluated for marrow signal changes deep to the root anchor, meniscal root signal intensity, medial compartment articular cartilage thinning, and meniscal body extrusion. Images of 29 age- and gender-matched individuals with two MRIs of the same knee were reviewed as a control group. MRI in 11 of 15 (73 %) cases with subsequent PHMMR tear demonstrated linear subcortical marrow edema deep to the meniscal root anchor on the antecedent MRI compared to only 1 of 29 (3 %) non-tear controls (p < 0.0001). The abnormal signal resolved on post-tear MRI in all but two patients. Cyst-like changes deep to the PHMMR were present on initial MRI in three of 15 (23 %) cases and three of 29 (10 %) controls, persisting in all but one case on follow-up imaging. The PHMMR was gray on the initial MRI in seven of 15 (47 %) of cases that developed tears compared to four of 29 (14 %) controls (p < 0.0001). There was medial meniscal extrusion (MME) prior to tear in two of 15 (13 %) patients and in ten of 15 (67 %) patients after PHMMR failure. In the control group, MME was present in one (3 %) and three (10 %) of 29 subjects on the initial and follow-up MRIs, respectively. Articular cartilage loss was noted in two of 15 (15 %) cases before tear and nine of 15 (69 %) on follow-up imaging, as compared to one (3 %) and four (14 %) of 29 subjects in the control group. Subcortical marrow edema deep to the PHMMR may result from abnormal stresses and thus be a harbinger of meniscal root failure. This hypothesis is supported by resolution of these marrow signal changes after root tear. Following tear, extrusion of the

  10. MENISCAL REPAIR BY FIBROCARTILAGE - AN EXPERIMENTAL-STUDY IN THE DOG

    NARCIS (Netherlands)

    JANSEN, HWB; VETH, RPH; NIELSEN, HKL; DEGROOT, JH; PENNINGS, AJ; KUIJER, R

    Longitudinal lesions in the avascular part of the dog's meniscus were repaired by implantation of a porous polyurethane. Ingrowing repair tissue was characterized by biochemical and immunological analysis. Histologically, repair tissue initially was composed of fibrous tissue containing type I

  11. Effect of load on the repair of osteochondral defects using a porous polymer scaffold

    NARCIS (Netherlands)

    Hannink, G.J.; de Mulder, E.L.; Tienen, T.G. van; Buma, P.

    2012-01-01

    The aim of the present study was to evaluate if a porous polymer scaffold, currently used for partial meniscal replacement in clinical practice, could initiate regeneration and repair of osteochondral defects, and if regeneration and repair were related to mechanical stimulation. Two equally sized

  12. Study protocol for a randomised controlled trial of meniscal surgery compared with exercise and patient education for treatment of meniscal tears in young adults

    DEFF Research Database (Denmark)

    Skou, Soren Thorgaard; Lind, Martin; Holmich, Per

    2017-01-01

    INTRODUCTION: Arthroscopic surgery is a very common orthopaedic procedure. While several trials have investigated the effect of knee arthroscopy for middle-aged and older patients with meniscal tears, there is a paucity of trials comparing meniscal surgery with non-surgical treatment for younger...... adults. The aim of this randomised controlled trial (RCT) is to investigate if early arthroscopic surgery is superior to exercise therapy and education, with the option of later surgery if needed, in improving pain, function and quality of life in younger adults with meniscal tears. METHODS AND ANALYSIS......: This is a protocol for a multicentre, parallel-group RCT conducted at six hospitals across all five healthcare regions in Denmark. 140 patients aged 18-40 years with a clinical history and symptoms consistent with a meniscal tear, verified on MRI, found eligible for meniscal surgery by an orthopaedic surgeon...

  13. Use of porous polyurethanes for meniscal reconstruction and meniscal prostheses

    NARCIS (Netherlands)

    deGroot, JH; deVrijer, R; Pennings, AJ; Veth, RPH; Jansen, HWB

    In the past, porous materials made of an aromatic polyurethane (PU) were successfully used for meniscal reconstruction in dogs. Since aromatic PUs yield very toxic fragments upon degradation, a linear PU was synthesized by curing a poly(epsilon-caprolactone) and 1,4-trans-cyclohexane diisocyanate I

  14. MRI diagnosis of meniscal tears

    International Nuclear Information System (INIS)

    Kuga, Naoyuki; Oh, Toshihiro

    1996-01-01

    We studied the accuracy of magnetic resonance imaging (MRI) of the knee in fifty-six patients who were also examined arthroscopically. The accuracy, sensitivity, and specificity were 96%, 100%, and 95% for medial meniscal tears, and 91%, 67%, and 100% for lateral meniscal tears respectively. Two MRIs of the medial meniscus were false-positives. These MRI findings were both meniscocapsular separation of the medial meniscus, but the arthroscopic findings were normal. One case was an ACL injury and the other PCL and MCL injury. Hemorrhage and edema of the medial capsule caused by valgus stress at injury may look like a meniscal pseudo-tear on MRI. Five MRIs of the lateral meniscus were false-negatives. All menisci showed normal signal and shape on MRI but traumatic and stable tears of the lateral meniscus were identified arthroscopically. All were associated with ACL tears and lateral condylar bone bruise. The traumatic and stable tear of the meniscus tended to be overlooked on MRI because a meniscus without degeneration shows a normal signal. (author)

  15. Changes in Contact Area in Meniscus Horizontal Cleavage Tears Subjected to Repair and Resection.

    Science.gov (United States)

    Beamer, Brandon S; Walley, Kempland C; Okajima, Stephen; Manoukian, Ohan S; Perez-Viloria, Miguel; DeAngelis, Joseph P; Ramappa, Arun J; Nazarian, Ara

    2017-03-01

    To assess the changes in tibiofemoral contact pressure and contact area in human knees with a horizontal cleavage tear before and after treatment. Ten human cadaveric knees were tested. Pressure sensors were placed under the medial meniscus and the knees were loaded at twice the body weight for 20 cycles at 0°, 10°, and 20° of flexion. Contact area and pressure were recorded for the intact meniscus, the meniscus with a horizontal cleavage tear, after meniscal repair, after partial meniscectomy (single leaflet), and after subtotal meniscectomy (double leaflet). The presence of a horizontal cleavage tear significantly increased average peak contact pressure and reduced effective average tibiofemoral contact area at all flexion angles tested compared with the intact state (P contact pressure after creation of the horizontal cleavage tear. Repairing the horizontal cleavage tear restored peak contact pressures and areas to within 15% of baseline, statistically similar to the intact state at all angles tested (P contact pressure and reduced average contact area at all degrees of flexion compared with the intact state (P contact area and a significant elevation in contact pressure. These changes may accelerate joint degeneration. A suture-based repair of these horizontal cleavage tears returns the contact area and contact pressure to nearly normal, whereas both partial and subtotal meniscectomy lead to significant reductions in contact area and significant elevations in contact pressure within the knee. Repairing horizontal cleavage tears may lead to improved clinical outcomes by preserving meniscal tissue and the meniscal function. Understanding contact area and peak contact pressure resulting from differing strategies for treating horizontal cleavage tears will allow the surgeon to evaluate the best strategy for treating his or her patients who present with this meniscal pathology. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier

  16. Detection of meniscal injuries using MR imaging

    International Nuclear Information System (INIS)

    Lotysch, M.; Mink, J.H.; Levy, T.; Schwartz, A.; Crues, J.V. III.

    1986-01-01

    Eighty-six knees studied by MR imaging were treated operatively and the surgical-radiologic conditions were reviewed using the following grading system of meniscal signal: grade 1, globular signal within the meniscus that does not involve an articular margin; grade 2, linear signal within the meniscus that does not extend to an articular surface; grade 3, linear or globular signal extending to an articular surface. This grading system was applied to evaluate 86 knees (172 menisci). Eleven menisci had been treated operatively at an earlier period and were excluded. Of 92 grade 1 or 2 menisci, 88 were normal at surgery. Of 69 grade 3 minisci, lesions were associated with meniscal tears in 68 at surgery. MR imaging is an accurate method of evaluating meniscal surgery

  17. Innovative Concrete Repairing Technique Using Post Tensioning Steel Straps

    Directory of Open Access Journals (Sweden)

    Ma Chau-Khun

    2017-01-01

    Full Text Available In this paper, innovative technique using low-cost recycled steel straps confinement to repair load-induced damaged high-strength concrete (HSC columns were studied. This paper explains the effects of repairing technique using post tensioning steel straps. A series of experimental test was carried out to investigate the stress-strain relationships of such concrete. A total of 6 HSC columns were compressed 50% of their ultimate strength, then repaired by using steel straps. The proposed repairing technique significantly improved the performance of damaged concrete columns, in both strength and ductility. It was evidenced from this study that the steel strapping confining technique is effective in repairing of damaged HSC columns but ensured reasonable operating costs.

  18. Inferomedial displacement of the meniscal free fragment: MR findings

    International Nuclear Information System (INIS)

    Sorrentino, Fortunato; Iovane, Angelo; Nicosia, Antonio; Candela, Fabrizio; Midiri, Massimo; De Maria, Marcello

    2005-01-01

    Purpose. To define the accuracy of Magnetic Resonance (MR) in the diagnosis of inferomedial displacement of the meniscal fragments. Materials and methods. The MR examinations of the knee performed between December 2002 and April 2004 on 676 patients (mean age 32 years) with knee trauma and subsequently subjected to arthroscopy were retrospectively reviewed to assess the presence of bucket-handle meniscal tear and inferomedial displacement of the meniscal free fragment. The MR examinations were performed using a superconductive 0.5 T MR unit with a transmitting/receiving coil dedicated for the extremities. The MR images were acquired with SE T1 and GE T2 sequences in the sagittal, coronal and axial planes with 3 mm thickness and 1 mm gap. The images were independently reviewed by two authors blinded to the arthroscopy findings. In case of disagreement, a third author, unaware of the arthroscopic findings, gave his judgment. Results. On MR images a bucket-handle meniscal tear was identified in 54/676 patients. In 6 out of 54 patients, an inferomedial meniscal fragment displacement of the medical meniscus with associated inflammatory synovial reaction around the distal insertion of the medial homolateral collateral ligament was detected. All cases were confirmed by arthroscopy and no statistical differences between the two authors were observed. Conclusions. MR allows the detection of the inferomedial meniscal fragment displacement and a more correct planning of arthroscopy with a strong reduction of repeat interventions [it

  19. Structural knee joint pathology in patients aged 40 years or older with meniscal tears

    DEFF Research Database (Denmark)

    Pihl, Kenneth; Englund, Martin; Lohmander, L S

    2017-01-01

    Purpose: Recent studies have challenged the tenet that mechanical symptoms of the knee (i.e. the sensation of catching or locking) are caused by degenerative meniscal tears per se and relieved by surgery. We explored the potential associations between meniscal and other knee joint pathologies...... identified at meniscal surgery with the presence of patient-reported mechanical symptoms. Methods: This study included patients aged 40 years or older undergoing surgery for a meniscal tear from the Knee Arthroscopy Cohort Southern Denmark (KACS). Patients were consecutively recruited from February 2013...... score (KOOS), together with information on previous meniscal surgery. At arthroscopy, the operating surgeon recorded information about specific meniscal pathology (tear location, depth, type, length, meniscal tissue quality and circumferential and radial location) and other structural knee pathologies...

  20. Wide Panel Testing Technique for Evaluating Repair Weld Strengths

    Science.gov (United States)

    Rogers, Patrick R.; Bynum, Julian E.; Shah, Sandeep R.

    1998-01-01

    This paper describes a new tensile testing technique for evaluating the overall effect of a repair weld on the strength of a welded joint. Previously, repair weld strengths have been evaluated using one-inch width tensile specimens, but this technique does not capture all of the effects that result from a repair. The new technique involves testing of "wide panel" tensile specimens which contain the full length of a repair weld within a longer initial weld, allowing the specimen to capture the combined effects of residual stresses, local strength degradation, and load redistribution around a repair. The development of strains in the repair area of standard aluminum alloy specimens and new high-performance aluminum-lithium alloy specimens was observed and evaluated using photoelastic material. The results of this evaluation show an increased sensitivity to repair welding residual stresses in the aluminum-lithium alloy specimens.

  1. Scaffold architecture and fibrin gels promote meniscal cell proliferation

    Energy Technology Data Exchange (ETDEWEB)

    Pawelec, K. M., E-mail: pawelec.km@gmail.com, E-mail: jw626@cam.ac.uk; Best, S. M.; Cameron, R. E. [Cambridge Centre for Medical Materials, Materials Science and Metallurgy Department, University of Cambridge, Cambridge CB3 0FS (United Kingdom); Wardale, R. J., E-mail: pawelec.km@gmail.com, E-mail: jw626@cam.ac.uk [Division of Trauma and Orthopaedic Surgery, Department of Surgery, University of Cambridge, Cambridge CB2 2QQ (United Kingdom)

    2015-01-01

    Stability of the knee relies on the meniscus, a complex connective tissue with poor healing ability. Current meniscal tissue engineering is inadequate, as the signals for increasing meniscal cell proliferation have not been established. In this study, collagen scaffold structure, isotropic or aligned, and fibrin gel addition were tested. Metabolic activity was promoted by fibrin addition. Cellular proliferation, however, was significantly increased by both aligned architectures and fibrin addition. None of the constructs impaired collagen type I production or triggered adverse inflammatory responses. It was demonstrated that both fibrin gel addition and optimized scaffold architecture effectively promote meniscal cell proliferation.

  2. [Progress of Masquelet technique to repair bone defect].

    Science.gov (United States)

    Yin, Qudong; Sun, Zhenzhong; Gu, Sanjun

    2013-10-01

    To summarize the progress of Masquelet technique to repair bone defect. The recent literature concerning the application of Masquelet technique to repair bone defect was extensively reviewed and summarized. Masquelet technique involves a two-step procedure. First, bone cement is used to fill the bone defect after a thorough debridement, and an induced membrane structure surrounding the spacer formed; then the bone cement is removed after 6-8 weeks, and rich cancellous bone is implanted into the induced membrane. Massive cortical bone defect is repaired by new bone forming and consolidation. Experiments show that the induced membrane has vascular system and is also rich in vascular endothelial growth factor, transforming growth factor beta1, bone morphogenetic protein 2, and bone progenitor cells, so it has osteoinductive property; satisfactory results have been achieved in clinical application of almost all parts of defects, various types of bone defect and massive defect up to 25 cm long. Compared with other repair methods, Masquelet technique has the advantages of reliable effect, easy to operate, few complications, low requirements for recipient site, and wide application. Masquelet technique is an effective method to repair bone defect and is suitable for various types of bone defect, especially for bone defects caused by infection and tumor resection.

  3. MRI follow-up of conservatively treated meniscal knee lesions in general practice

    Energy Technology Data Exchange (ETDEWEB)

    Oei, Edwin H.G.; Hunink, M.G.M. [University Medical Center Rotterdam, Program for the Assessment of Radiological Technology (ART Program), Erasmus MC, Rotterdam (Netherlands); University Medical Center Rotterdam, Department of Radiology, Erasmus MC, Rotterdam (Netherlands); University Medical Center Rotterdam, Department of Epidemiology, Erasmus MC, Rotterdam (Netherlands); Koster, Ingrid M. [University Medical Center Rotterdam, Department of Radiology, Erasmus MC, Rotterdam (Netherlands); Maasstad Ziekenhuis, Department of Radiology, Rotterdam (Netherlands); Hensen, Jan-Hein J.; Vroegindeweij, Dammis [Maasstad Ziekenhuis, Department of Radiology, Rotterdam (Netherlands); Boks, Simone S. [University Medical Center Rotterdam, Department of General Practice, Erasmus MC, Rotterdam (Netherlands); Maasstad Ziekenhuis, Department of Radiology, Rotterdam (Netherlands); Diaconessenhuis Meppel, Department of Radiology, Meppel (Netherlands); Wagemakers, Harry P.A.; Koes, Bart W.; Bierma-Zeinstra, Sita M.A. [University Medical Center Rotterdam, Department of General Practice, Erasmus MC, Rotterdam (Netherlands)

    2010-05-15

    To evaluate meniscal status change on follow-up MRI after 1 year, prognostic factors and association with clinical outcome in patients with conservatively treated knee injury. We analysed 403 meniscal horns in 101 conservatively treated patients (59 male; mean age 40 years) in general practice who underwent initial knee MRI within 5 weeks of trauma. We performed ordinal logistic regression analysis to analyse prognostic factors for meniscal change on follow-up MRI after 1 year, and we assessed the association with clinical outcome. On follow-up MRI 49 meniscal horns had deteriorated and 18 had improved. Age (odds ratio [OR] 1.3/decade), body weight (OR 1.2/10 kg), total anterior cruciate ligament (ACL) rupture on initial MRI (OR 2.4), location in the posterior horn of the medial meniscus (OR 3.0) and an initial meniscal lesion (OR 0.3) were statistically significant predictors of meniscal MRI appearance change after 1 year, which was not associated with clinical outcome. In conservatively treated patients, meniscal deterioration on follow-up MRI 1 year after trauma is predicted by higher age and body weight, initial total ACL rupture, and location in the medial posterior horn. Change in MRI appearance is not associated with clinical outcome. (orig.)

  4. Meniscal configuration using magnetic resonance imaging; Configuracao meniscal pela ressonancia magnetica

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Arthur da Rocha C.; Turrini, Elisabete; Karoauk, Teresa C.C.; Lederman, Henrique M. [Escola Paulista de Medicina, Sao Paulo, SP (Brazil). Dept. de Diagnostico por Imagem

    1997-04-01

    The authors present a review of the normal meniscal configuration and correlation with anatomic specimens. The images were obtained by magnetic resonance imaging. The images were obtained by magnetic resonance imaging. The authors emphasize the importance of knowing the relationship between the meniscus and the adjacent anatomic structures. (author) 31 refs., 10 figs., tabs.

  5. Snapping Knee Caused by Medial Meniscal Cyst

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Ohishi

    2014-01-01

    Full Text Available Snapping phenomenon around the medial aspect of the knee is rare. We present this case of snapping knee caused by the sartorius muscle over a large medial meniscal cyst in a 66-year-old female. Magnetic resonance images demonstrated a large medial meniscal cyst with a horizontal tear of the medial meniscus. Arthroscopic cyst decompression with limited meniscectomy resulted in the disappearance of snapping, and no recurrence of the cyst was observed during a 2-year follow-up period.

  6. Meniscal abnormalities in soccer players: prevalence and MR imaging

    International Nuclear Information System (INIS)

    Song, In Sup; Lee, Jong Ik; Kwak, Byeung Kook; Shim, Hyung Jin; Lee, Jong Beum; Lee, Yong Chul; Kim, Kun Sang; Seo, Kyung Mook

    1995-01-01

    We aimed to know the prevalence of abnormal meniscal signal on MR imaging in asymptomatic soccer players and its radiologic significance. Using T1 and gradient echo T2 weighted sagittal and coronal MR image, 48 knees in twenty-four full time soccer players were evaluated for the meniscal abnormalities, the status of ligament and existence of joint effusion. Meniscal abnormalities were interpreted using grading system of Lotysch. By using Chi-square method. We analyzed the existence of joint effusion could divide the healing state and healed state of the meniscus. The prevalence of Grade 2 and more and Grade 3 were 42% and 39% of asymptomatic knees. In the 24 knees with meniscus tear, nine of the 14 asymptomatic knee showed effusion while eight of the 10 symptomatic knee did. Of 24 knees with meniscal tear, only eleven knees were related to previous history of major knee trauma. The prevalence of meniscal abnormalities on MR imaging in asymptomatic soccer players was higher (grade 3: 39%) than we expected. The joint effusion was not helpful to divide the healing state and healed state of the meniscus. So we suggest baseline MR imaging in the athletes who have been using the knee vigorously could give decisive information for the interpretation of subsequent MRI that may be performed when the players wounded

  7. In vitro synthesis of tensioned synoviocyte bioscaffolds for meniscal fibrocartilage tissue engineering.

    Science.gov (United States)

    Warnock, Jennifer J; Baker, Lindsay; Ballard, George A; Ott, Jesse

    2013-12-03

    Meniscal injury is a common cause of lameness in the dog. Tissue engineered bioscaffolds may be a treatment option for meniscal incompetency, and ideally would possess meniscus- like extracellular matrix (ECM) and withstand meniscal tensile hoop strains. Synovium may be a useful cell source for meniscal tissue engineering because of its natural role in meniscal deficiency and its in vitro chondrogenic potential. The objective of this study is to compare meniscal -like extracellular matrix content of hyperconfluent synoviocyte cell sheets ("HCS") and hyperconfluent synoviocyte sheets which have been tensioned over wire hoops (tensioned synoviocyte bioscaffolds, "TSB") and cultured for 1 month. Long term culture with tension resulted in higher GAG concentration, higher chondrogenic index, higher collagen concentration, and type II collagen immunoreactivity in TSB versus HCS. Both HCS and TSB were immunoreactive for type I collagen, however, HCS had mild, patchy intracellular immunoreactivity while TSB had diffuse moderate immunoreactivity over the entire bisocaffold. The tissue architecture was markedly different between TSB and HCS, with TSB containing collagen organized in bands and sheets. Both HCS and TSB expressed alpha smooth muscle actin and displayed active contractile behavior. Double stranded DNA content was not different between TSB and HCS, while cell viability decreased in TSB. Long term culture of synoviocytes with tension improved meniscal- like extra cellular matrix components, specifically, the total collagen content, including type I and II collagen, and increased GAG content relative to HCS. Future research is warranted to investigate the potential of TSB for meniscal tissue engineering.

  8. Tissue-Derived Extracellular Matrix Bioscaffolds: Emerging Applications in Cartilage and Meniscus Repair.

    Science.gov (United States)

    Monibi, Farrah A; Cook, James L

    2017-08-01

    Musculoskeletal injuries are a common problem in orthopedic practice. Given the long-term consequences of unaddressed cartilage and meniscal pathology, a number of treatments have been attempted to stimulate repair or to replace the injured tissue. Despite advances in orthopedic surgery, effective treatments for cartilage and meniscus injuries remain a significant clinical challenge. Tissue engineering is a developing field that aims to regenerate injured tissues with a combination of cells, scaffolds, and signals. Many natural and synthetic scaffold materials have been developed and tested for the repair and restoration of a number of musculoskeletal tissues. Among these, biological scaffolds derived from cell and tissue-derived extracellular matrix (ECM) have shown great promise in tissue engineering given the critical role of the ECM for maintaining the biological and biomechanical properties, structure, and function of native tissues. This review article presents emerging applications for tissue-derived ECM scaffolds in cartilage and meniscus repair. We examine normal ECM composition and the current and future methods for potential treatment of articular cartilage and meniscal defects with decellularized scaffolds.

  9. An Overview of Corroded Pipe Repair Techniques Using Composite Materials

    OpenAIRE

    K. S. Lim; S. N. A. Azraai; N. M. Noor; N. Yahaya

    2015-01-01

    Polymeric composites are being increasingly used as repair material for repairing critical infrastructures such as building, bridge, pressure vessel, piping and pipeline. Technique in repairing damaged pipes is one of the major concerns of pipeline owners. Considerable researches have been carried out on the repair of corroded pipes using composite materials. This article attempts a short review of the subject matter to provide insight into various techniques used in repa...

  10. Chronic anterior cruciate ligament tears and associated meniscal and traumatic cartilage lesions: evaluation with morphological sequences at 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Vlychou, Marianna; Fezoulidis, Ioannis V. [University Hospital of Larissa, Department of Radiology, Medical School of Thessaly, Larissa (Greece); Hantes, Michalis; Michalitsis, Sotirios; Malizos, Konstantinos [University Hospital of Larissa, Department of Orthopaedic Surgery, Medical School of Thessaly, Larissa (Greece); Tsezou, Aspasia [University Hospital of Larissa, Department of Molecular Genetics and Cytogenetics, Medical School of Thessaly, Larissa (Greece)

    2011-06-15

    To investigate the diagnostic efficacy of morphological sequences at 3.0 T MR imaging in detecting anterior cruciate ligament (ACL), meniscal pathology and traumatic cartilage legions in young patients with chronic deficient anterior cruciate ligament knees. This prospective study included 43 patients (39 male) between the age of 15 and 37 years (mean age 22.6 years) with a history of knee injury sustained at least 3 months prior to the decision to repair a torn ACL. All patients underwent a 3.0 T MR scan with the same standard protocol, including intermediate-weighted and three-dimensional spoiled gradient-recalled T1-weighted sequences with fat saturation and subsequently surgical reconstruction of the ACL, along with meniscal and cartilage repair, when necessary. All ACL tears were correctly interpreted by 3.0 T MR images. The sensitivity of the MR scans regarding tears of the medial meniscus was 93.7%, the specificity 92.6%, the positive predictive value 88.2% and the negative predictive value 95.8%. The sensitivity of the MR scans regarding tears of lateral meniscus was 85.7%, the specificity was 93.1%, the positive predictive value 85.7% and the negative predictive value 93.1%. With regard to the grading of the cartilage lesions, Cohen's kappa coefficient indicated moderate agreement for grade I and II cartilage lesions (0.5), substantial agreement for grade III and IV cartilage lesions (0.70 and 0.66) and substantial agreement for normal regions (0.75). Regarding location of the cartilage lesions, Cohen's kappa coefficient varied between almost perfect agreement in the lateral femoral condyle and no agreement in the trochlea. In the setting of chronic ACL deficiency, MR imaging at 3.0 T achieves satisfactory diagnostic performance regarding meniscal and ligamentous pathology. In the detection of cartilage lesions MRI is less successful. (orig.)

  11. Integrity of articular cartilage on T2 mapping associated with meniscal signal change

    International Nuclear Information System (INIS)

    Kai, Brian; Mann, Sumeer A.; King, Chris; Forster, Bruce B.

    2011-01-01

    Objective: The purpose of this study was to investigate the relationship between T2 relaxation values (T2 RVs) within the superficial zone of articular cartilage and different types of meniscal degeneration/tear. Materials and methods: A review of 310 consecutive knee MRIs which included an 8 echo T2 relaxation sequence, in patients referred for standard clinical indications, was performed independently and in blinded fashion by 2 observers. The posterior horns of the medial and lateral menisci were each evaluated and divided into 4 subgroups: Normal (control), Grade I/II meniscal signal, Grade III meniscal signal-simple tear (Grade III-S), and Grade III meniscal signal-complex tear (Grade III-C). After exclusion criteria were applied, the medial meniscal group consisted of 65 controls and 133 patients, while the lateral meniscal group consisted of 143 controls and 55 patients. T2 RVs were measured by an observer blinded to the clinical history and MRI grading. Measurements were obtained over the superficial zone of femoral and tibial articular cartilage adjacent to the center of the posterior horn of each meniscus to ensure consistency between measurements. Analysis of covariance adjusting for age and gender was used to compare T2 RVs between patients and controls. Results: T2 RVs were significantly increased in patients with Grade III-C meniscal tears compared to controls over the medial tibial plateau (MTP; p = 0.0001) and lateral tibial plateau (LTP; p = 0.0008). T2 RVs were not increased in patients with Grade III-C meniscal tears over the medial femoral condyle (MFC; p = 0.11) or lateral femoral condyle (LFC; p = 0.99). Grade I/II meniscal signal was not associated with elevated T2 RVs over the MFC (p = 0.15), LFC (p = 0.69), MTP (p = 0.42), or LTP (p = 0.50). Grade III-S meniscal signal was not associated with elevated T2 RVs over the MFC (p = 0.54), LFC (p = 0.43), MTP (p = 0.30), or LTP (p = 0.38). Conclusion: Grade III-C meniscal tears are associated with

  12. Integrity of articular cartilage on T2 mapping associated with meniscal signal change

    Energy Technology Data Exchange (ETDEWEB)

    Kai, Brian [Department of Radiology, University of British Columbia, UBC Hospital, 2211 Wesbrook Mall, Vancouver, BC, V6T 2B5 (Canada); Mann, Sumeer A. [Department of Radiology, University of Alberta, Walter Mackenzie Health Sciences Center, Edmonton, AB, T6G 2B7 (Canada); King, Chris [Department of Radiology, University of British Columbia, UBC Hospital, 2211 Wesbrook Mall, Vancouver, BC, V6T 2B5 (Canada); Forster, Bruce B., E-mail: bruce.forster@vch.ca [Department of Radiology, University of British Columbia, UBC Hospital, 2211 Wesbrook Mall, Vancouver, BC, V6T 2B5 (Canada)

    2011-09-15

    Objective: The purpose of this study was to investigate the relationship between T2 relaxation values (T2 RVs) within the superficial zone of articular cartilage and different types of meniscal degeneration/tear. Materials and methods: A review of 310 consecutive knee MRIs which included an 8 echo T2 relaxation sequence, in patients referred for standard clinical indications, was performed independently and in blinded fashion by 2 observers. The posterior horns of the medial and lateral menisci were each evaluated and divided into 4 subgroups: Normal (control), Grade I/II meniscal signal, Grade III meniscal signal-simple tear (Grade III-S), and Grade III meniscal signal-complex tear (Grade III-C). After exclusion criteria were applied, the medial meniscal group consisted of 65 controls and 133 patients, while the lateral meniscal group consisted of 143 controls and 55 patients. T2 RVs were measured by an observer blinded to the clinical history and MRI grading. Measurements were obtained over the superficial zone of femoral and tibial articular cartilage adjacent to the center of the posterior horn of each meniscus to ensure consistency between measurements. Analysis of covariance adjusting for age and gender was used to compare T2 RVs between patients and controls. Results: T2 RVs were significantly increased in patients with Grade III-C meniscal tears compared to controls over the medial tibial plateau (MTP; p = 0.0001) and lateral tibial plateau (LTP; p = 0.0008). T2 RVs were not increased in patients with Grade III-C meniscal tears over the medial femoral condyle (MFC; p = 0.11) or lateral femoral condyle (LFC; p = 0.99). Grade I/II meniscal signal was not associated with elevated T2 RVs over the MFC (p = 0.15), LFC (p = 0.69), MTP (p = 0.42), or LTP (p = 0.50). Grade III-S meniscal signal was not associated with elevated T2 RVs over the MFC (p = 0.54), LFC (p = 0.43), MTP (p = 0.30), or LTP (p = 0.38). Conclusion: Grade III-C meniscal tears are associated with

  13. Retrograde Ascending Dissection After Thoracic Endovascular Aortic Repair Combined With the Chimney Technique and Successful Open Repair Using the Frozen Elephant Trunk Technique.

    Science.gov (United States)

    Hirano, Koji; Tokui, Toshiya; Nakamura, Bun; Inoue, Ryosai; Inagaki, Masahiro; Maze, Yasumi; Kato, Noriyuki

    2018-01-01

    The chimney technique can be combined with thoracic endovascular aortic repair (TEVAR) to both obtain an appropriate landing zone and maintain blood flow of the arch vessels. However, surgical repair becomes more complicated if retrograde type A aortic dissection occurs after TEVAR with the chimney technique. We herein report a case involving a 73-year-old woman who developed a retrograde ascending dissection 3 months after TEVAR for acute type B aortic dissection. To ensure an adequate proximal sealing distance, the proximal edge of the stent graft was located at the zone 2 level and an additional bare stent was placed at the left subclavian artery (the chimney technique) at the time of TEVAR. Enhanced computed tomography revealed an aortic dissection involving the ascending aorta and aortic arch. Surgical aortic repair using the frozen elephant trunk technique was urgently performed. The patient survived without stroke, paraplegia, renal failure, or other major complications. Retrograde ascending dissection can occur after TEVAR combined with the chimney technique. The frozen elephant trunk technique is useful for surgical repair in such complicated cases.

  14. Meniscal repair by fibrocartilage in the dog : Characterization of the repair tissue and the role of vascularity

    NARCIS (Netherlands)

    Veth, RPH; Jansen, HWB; Nielsen, HKL; deGroot, JH; Pennings, AJ; Kuijer, R

    Lesions in the avascular part of 20 canine menisci were repaired by implantation of a porous polyurethane. Seven menisci were not repaired and served as controls. The repair tissue was characterized by biochemical and immunological analysis. The role of vascularity in healing was studied by

  15. A technique for introducing looped sutures in flexor tendon repair

    Directory of Open Access Journals (Sweden)

    Kamath B

    2006-01-01

    Full Text Available Stronger flexor tendon repairs facilitate early active motion therapy protocols. Core sutures using looped suture material provide 1 ½ to twice the strength of Kessler′s technique (with four strand and six strand Tsuge technique respectively. The technique is well-described and uses preformed looped sutures (supramid. This is not available in many countries and we describe a technique whereby looped sutures can be introduced in flexor tendon repair by the use of 23 G hypodermic needle and conventional 4.0 or 5.0 sutures. This is an alternative when the custom made preformed sutures are not available. This can be practiced in zone 3 to zone 5 repairs. Technical difficulties limit its use in zone 2 repairs.

  16. A comparison of arthrography to clinical diagnostics for diagnosing meniscal lesions

    International Nuclear Information System (INIS)

    Neuer, H.

    1982-01-01

    A comparative investigation as to the exactness of clinical and arthrographical diagnostics was carried out on 176 patients who were clinically examined and operated on in the period of 1972-1980. Using solely clinical diagnostics, the total rate of exactness was 90,9%, the exactness regarding the internal meniscal lesion being significantly higher (94.2%) than that regarding external meniscal lesion (76.7%). Using solely arthrographic diagnostics, the total rate of exactness was 82%, the rate for internal meniscus being significantly lower (83.9%) than that obtained using clinical diagnostics. As for the external meniscus, the exactness of arthrography differs only slightly from clinical diagnostics with 74.7%. The most frequent sources of error in arthorgraphy were found to be lesions of the posterior horn at the internal meniscus. In cases of external meniscal lesions, especially when an internal meniscal lesion was existing at the same time, both examination methods failed in 5 cases. For routine diagnosing of meniscal lesions, arthrography is not necessary. An accurate clinical examination and anamnesis bring very good and exact results and should therefore be given absolute priority. (orig./MG) [de

  17. Fundamental study on repairing technique for cracked or damaged parts of structures by cold gas dynamic spray technique

    International Nuclear Information System (INIS)

    Ogawa, Kazuhiro; Amao, Satoshi; Ichikawa, Yuji; Shoji, Tetsuo

    2008-01-01

    This study proposes an innovative technique for repairing of cracked or damaged parts of structures, such as nuclear or thermal power plants, by means of cold gas dynamic spray (CS) technique. In the case of generation of cracks etc. in the structure, the cracks can be repaired by welding. However, the welding spends considerable time on repair, and also needs special skills. The CS technique is known as a new technique not only for coatings but also for thick depositions. It has many advantages, i.e. dense deposition, high deposition rate and low oxidation. Therefore, it has a possibility to apply the CS technique instead of welding to repair the cracks etc. In this study, the cold gas dynamic spray technique as a new repairing technique for some structures is introduced. (author)

  18. Effectiveness and biocompatibility of a novel biological adhesive application for repair of meniscal tear on the avascular zone

    Science.gov (United States)

    Inoue, Takahito; Taguchi, Tetsushi; Imade, Shinji; Kumahashi, Nobuyuki; Uchio, Yuji

    2012-12-01

    We have investigated the effectiveness and safety of a newly developed biological adhesive for repair of meniscal tear. The adhesive was composed of disuccinimidyl tartrate (DST) as a crosslinker and human serum albumin (HSA) as a hardener. To determine adequate concentration, bonding strength was measured using a tensiometer 5 min after applying the adhesive on the avascular zone tear of porcine meniscus; it was compared with the strengths of commercially available cyanoacrylate-based and fibrin-based adhesives. In vivo examination was performed using Japanese white rabbits, creating longitudinal tears on the avascular zone of meniscus and applying DST-HSA adhesive. Three months after operation the rabbits were sacrificed and tension test and histological evaluation were performed. Bonding strength was measured in three porcine meniscus groups: (i) only suturing, (ii) suturing after applying the adhesive on surface and (iii) suturing using an adhesive-soaked suture. The optimum concentrations were 0.1 mmol of DST and 42 w/v% of HAS. Bonding strength was greatest with cyanoacrylate-based adhesive, followed by DST-HSA adhesive, and fibrin-based adhesive. No inflammation was observed in the synovium or surrounding tissues 3 months after using the DST-HSA adhesive. Bonding strength was greatest with DST-HSA adhesive-soaked suturing group (77 ± 6 N), followed by suturing only group (61 ± 5 N) and surface adhesive application group (60 ± 8 N). The newly developed DST-HSA adhesive is considered safe and may be effective in enforcement of bonding of avascular zone tear of the meniscus.

  19. Biomechanical comparison of single-row arthroscopic rotator cuff repair technique versus transosseous repair technique.

    Science.gov (United States)

    Tocci, Stephen L; Tashjian, Robert Z; Leventhal, Evan; Spenciner, David B; Green, Andrew; Fleming, Braden C

    2008-01-01

    This study determined the effect of tear size on gap formation of single-row simple-suture arthroscopic rotator cuff repair (ARCR) vs transosseous Mason-Allen suture open RCR (ORCR) in 13 pairs of human cadaveric shoulders. A massive tear was created in 6 pairs and a large tear in 7. Repairs were cyclically tested in low-load and high-load conditions, with no significant difference in gap formation. Under low-load, gapping was greater in massive tears. Under high-load, there was a trend toward increased gap with ARCR for large tears. All repairs of massive tears failed in high-load. Gapping was greater posteriorly in massive tears for both techniques. Gap formation of a modeled RCR depends upon the tear size. ARCR of larger tears may have higher failure rates than ORCR, and the posterior aspect appears to be the site of maximum gapping. Specific attention should be directed toward maximizing initial fixation of larger rotator cuff tears, especially at the posterior aspect.

  20. The role of an axial MR scan on the diagnosis a meniscal tear of the knee joint

    International Nuclear Information System (INIS)

    Yeom, Suk Keu; Kim, Baek Hyun; Hong, Suk Joo; Seol, Hae Young

    2007-01-01

    To evaluate the role of standard axial MR images for the diagnosis for meniscal tears of the knee. Forty-five patients with a prior MRI examination that underwent arthroscopic surgery of the knee due to clinical impression of a meniscal tear were included in the study group. The sequence for meniscal evaluation was an axial fat-saturated proton density-weighted image with a 4 mm slice thickness. Axial MR images were independently reviewed by two radiologists and were compared with findings of arthroscopy. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of the axial MR scan for the diagnosis of the meniscal tear were calculated. A total 90 menisci of 45 patients were evaluated in the axial MR scans. Forty-two patients had meniscal tears, and two of the patients had tears in both menisci; thus, a total of 44 meniscal tears were found by arthroscopy. For meniscal tears, the sensitivity of the axial plane was 76.2%, the specificity was 89.1% and the accuracy was 81.1%. False negative meniscal tears were seen in 12 cases and false positive meniscal tears were seen in 5 cases on the axial MR images. In standard knee MRI examinations, axial images may be valuable for the detection and localization of meniscal tears

  1. Advanced inspection and repair techniques for primary side components

    International Nuclear Information System (INIS)

    Elm, Ralph

    1998-01-01

    The availability of nuclear power plant mainly depends on the components of the Nuclear Steam Supply System (NSSS) such as reactor pressure vessel, core internals and steam generators. The last decade has been characterized by intensive inspection and repair work on PWR steam generators. In the future, it can be expected, that the inspection of the reactor pressure vessel and the inspection and repair of its internals, in both PWR and BWR will be one of the challenges for the nuclear community. Due to this challenge, new, advanced inspection and repair techniques for the vital primary side components have been developed and applied, taking into account such issues as: use of reliable and fast inspection methods, repair of affected components instead of costly replacement, reduction of outage time compared to conventional methods, minimized radiation exposure, acceptable costs. This paper reflects on advanced inspection and repair techniques such as: Baffle Former Bolt inspection and replacement, Barrel Former Bolt inspection and replacement, Mechanized UT and visual inspection of reactor pressure vessels, Steam Generator repair by advanced sleeving technology. The techniques described have been successfully applied in nuclear power plants and improved the operation performance of the components and the NPP. (author). 6 figs

  2. Factors Influencing Choice of Inguinal Hernia Repair Technique ...

    African Journals Online (AJOL)

    Background: Inguinal hernia repair surgery is one of the most frequently performed surgical procedures worldwide. This study sought to highlight factors that may influence decisions concerning inguinal hernia repair techniques. Methods: This descriptive crosssectional study was carried out in September 2014 among ...

  3. Ultrasound-guided percutaneous drainage of meniscal cysts: preliminary clinical experience

    International Nuclear Information System (INIS)

    MacMahon, P.J.; Brennan, D.D.; Duke, D.; Forde, S.; Eustace, S.J.

    2007-01-01

    Aim: To evaluate the efficacy of ultrasound-guided percutaneous drainage of symptomatic meniscal cysts. Materials and methods: Patients with lateral knee joint tenderness and swelling and confirmed meniscal cyst on magnetic resonance imaging (MRI) were consecutively enrolled for ultrasound-guided percutaneous cyst aspiration. Cysts were injected with local anaesthetic and steroid before completion of procedure. All 18 patients (all male, average age 33 years) were subsequently followed up (average time 10 months) and meniscal cyst symptoms assessed by questionnaire. Fischer's exact test used to analyse the data. Results: In every case the procedure was well tolerated, and each patient indicated that they would be willing to have a repeat procedure in the future. Ten patients reported complete resolution of symptoms secondary to therapeutic cyst aspiration and had resumed participation in high-performance sport. Two patients reported a satisfactory sustained response, reporting only occasional 'twinges of pain'. In the remaining six patients, symptoms returned after an initial pain-free period. The pain-free period ranged from 1-8 weeks. In this study, patient outcome did not significantly correlate with any meniscal cyst characteristic. Conclusion: Ultrasound-guided percutaneous aspiration of meniscal cysts is a well-tolerated, simple, and safe procedure. In this small patient series, it was associated with positive early results with favourable outcomes in the mid to long-term. It should be considered in patients unsuitable for surgical debridement or as an interim therapy if surgery is delayed or postponed

  4. MRI versus ultrasonography to assess meniscal abnormalities in acute knees.

    Science.gov (United States)

    Cook, James L; Cook, Cristi R; Stannard, James P; Vaughn, Gavin; Wilson, Nichole; Roller, Brandon L; Stoker, Aaron M; Jayabalan, Prakash; Hdeib, Moses; Kuroki, Keiichi

    2014-08-01

    While magnetic resonance imaging (MRI) is often considered the "gold standard" diagnostic imaging modality for detection of meniscal abnormalities, it is associated with misdiagnosis in as high as 47% of cases, is costly, and is not readily available to a large number of patients. Ultrasonographic examination of the knee has been reported to be an effective diagnostic tool for this purpose with the potential to overcome many of the shortcomings of MRI. The purpose of this study is to determine the clinical usefulness of ultrasonography for diagnosis of meniscal pathology in patients with acute knee pain and compare its diagnostic accuracy to MRI in a clinical setting. With Institutional Review Board approval, patients (n = 71) with acute knee pain were prospectively enrolled with informed consent. Preoperative MRI (1.5 T) was performed on each affected knee using the hospital's standard equipment and protocols and read by faculty radiologists trained in musculoskeletal MRI. Ultrasonographic assessments of each affected knee were performed by one of two faculty members trained in musculoskeletal ultrasonography using a 10 to 14 MHz linear transducer. Arthroscopic evaluation of affected knees was performed by one of three faculty orthopedic surgeons to assess and record all joint pathology, which served as the reference standard for determining presence, type, and severity of meniscal pathology. All evaluators for each diagnostic modality were blinded to all other data. Data were collected and compared by a separate investigator to determine sensitivity (Sn), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), correct classification rate (CCR), likelihood ratios (LR[+] and LR[-]), and odds ratios. Preoperative ultrasonographic assessment of meniscal pathology was associated with Sn = 91.2%, Sp = 84.2%, PPV = 94.5%, NPV = 76.2%, CCR = 89.5%, LR(+) = 5.78, and LR(-) = 0.10. Preoperative MRI assessment of

  5. Cost effectiveness of meniscal allograft for torn discoid lateral meniscus in young women.

    Science.gov (United States)

    Ramme, Austin J; Strauss, Eric J; Jazrawi, Laith; Gold, Heather T

    2016-09-01

    A discoid meniscus is more prone to tears than a normal meniscus. Patients with a torn discoid lateral meniscus are at increased risk for early onset osteoarthritis requiring total knee arthroplasty (TKA). Optimal management for this condition is controversial given the up-front cost difference between the two treatment options: the more expensive meniscal allograft transplantation compared with standard partial meniscectomy. We hypothesize that meniscal allograft transplantation following excision of a torn discoid lateral meniscus is more cost-effective compared with partial meniscectomy alone because allografts will extend the time to TKA. A decision analytic Markov model was created to compare the cost effectiveness of two treatments for symptomatic, torn discoid lateral meniscus: meniscal allograft and partial meniscectomy. Probability estimates and event rates were derived from the scientific literature, and costs and benefits were discounted by 3%. One-way sensitivity analyses were performed to test model robustness. Over 25 years, the partial meniscectomy strategy cost $10,430, whereas meniscal allograft cost on average $4040 more, at $14,470. Partial meniscectomy postponed TKA an average of 12.5 years, compared with 17.30 years for meniscal allograft, an increase of 4.8 years. Allograft cost $842 per-year-gained in time to TKA. Meniscal allografts have been shown to reduce pain and improve function in patients with discoid lateral meniscus tears. Though more costly, meniscal allografts may be more effective than partial meniscectomy in delaying TKA in this model. Additional future long term clinical studies will provide more insight into optimal surgical options.

  6. Is radiographic measurement of bony landmarks reliable for lateral meniscal sizing?

    Science.gov (United States)

    Yoon, Jung-Ro; Kim, Taik-Seon; Lim, Hong-Chul; Lim, Hyung-Tae; Yang, Jae-Hyuk

    2011-03-01

    The accuracy of meniscal measurement methods is still in debate. The authors' protocol for radiologic measurements will provide reproducible bony landmarks, and this measurement method of the lateral tibial plateau will correlate with the actual anatomic value. Controlled laboratory study. Twenty-five samples of fresh lateral meniscus with attached proximal tibia were obtained during total knee arthroplasty. Each sample was obtained without damage to the meniscus and bony attachment sites. The inclusion criterion was mild to moderate osteoarthritis in patients with mechanical axis deviation of less than 15°. Knees with lateral compartment osteoarthritic change or injured or degenerated menisci were excluded. For the lateral tibial plateau length measurements, the radiographic beam was angled 10° caudally at neutral rotation, which allowed differentiation of the lateral plateau cortical margins from the medial plateau. The transition points were identified and used for length measurement. The values of length were then compared with the conventional Pollard method and the anatomic values. The width measurement was done according to Pollard's protocol. For each knee, the percentage deviation from the anatomic dimension was recorded. Intraobserver error and interobserver error were calculated. The deviation of the authors' radiographic length measurements from anatomic dimensions was 1.4 ± 1.1 mm. The deviation of Pollard's radiographic length measurements was 4.1 ± 2.0 mm. With respect to accuracy-which represents the frequency of measurements that fall within 10% of measurements-the accuracy of authors' length was 98%, whereas for Pollard's method it was 40%. There was a good correlation between anatomic meniscal dimensions and each radiologic plateau dimensions for lateral meniscal width (R(2) = .790) and the authors' lateral meniscal length (R(2) = .823) and fair correlation for Pollard's lateral meniscal length (R(2) = .660). The reliability of each

  7. Sonographic Imaging of Meniscal Subluxation in Patients with Radiographic Knee Osteoarthritis

    Directory of Open Access Journals (Sweden)

    Chun-Hung Ko

    2007-09-01

    Conclusion: Meniscal subluxation is a prominent feature on weight-bearing sonographic imaging in patients with radiographic osteoarthritis and could be considered as a risk factor for the development of knee osteoarthritis. By using musculoskeletal ultrasonography, one can detect this occult meniscal derangement early before the appearance of radiographic signs of osteoarthritis.

  8. Patient reported outcomes in patients undergoing arthroscopic partial meniscectomy for traumatic or degenerative meniscal tears

    DEFF Research Database (Denmark)

    Thorlund, Jonas Bloch; Englund, Martin; Christensen, Robin

    2017-01-01

    OBJECTIVES: To compare patient reported outcomes from before surgery to 52 weeks after surgery between individuals undergoing arthroscopic partial meniscectomy for traumatic meniscal tears and those for degenerative meniscal tears. DESIGN: Comparative prospective cohort study. SETTING: Four public......-55, and undergoing arthroscopic partial meniscectomy for a traumatic or degenerative meniscal tear (defined by a combination of age and symptom onset). INTERVENTIONS: Both participant groups underwent arthroscopic partial meniscectomy for a meniscal tear, with operating surgeons recording relevant information......% women) with a traumatic or degenerative meniscal tear (n=141, mean age 38.7 years (standard deviation 10.9); n=256, 46.6 years (6.4); respectively) were included in the main analysis. At 52 weeks after arthroscopic partial meniscectomy, 55 (14%) patients were lost to follow-up. Statistically...

  9. MR imaging of displaced meniscal tears of the knee. Importance of a 'disproportional posterior horn sign'

    International Nuclear Information System (INIS)

    Chen, H.C.; Hsu, C.Y.; Shih, T.T.F.; Huang, K.M.; Li, Y.W.

    2001-01-01

    Purpose: Meniscal tears associated with displaced fragments are clinically significant. We propose the 'disproportional posterior horn sign' as a supportive criterion to identify a posterocentrally displaced meniscal fragment on MR imaging studies. If the meniscal posterior horn in the central portion appears larger than that in the peripheral section, it is considered positive for 'disproportional posterior horn sign'. Material and Methods: MR images obtained in 42 patients with 43 lesions, confirmed to have displaced meniscal tears, were included in this study. The MR images were retrospectively evaluated for the presence of the 'disproportional posterior horn sign', as well as the other known signs. Results: The 'disproportional posterior horn sign' was seen in 9 (20.9%) of 43 lesions, including 1 lateral discoid meniscal tear, 5 lateral meniscal tears and 3 medial meniscal tears. Five of them also had other signs of a displaced meniscal fragment. However, the remaining 4 cases only exhibited the 'disproportional posterior horn sign'. For the other MR signs, the 'absent bow tie sign' was detected in 40 (93%) of 43 lesions, the 'flipped meniscus sign' in 27 (62.8%) of 43 lesions, the 'double posterior cruciate ligament sign' in 17 (39.5%) of 43 lesions and the 'notch fragment sign' in 22 (51.2%) of 43 lesions. Conclusion: The 'disproportional posterior horn sign' is helpful in demonstrating a posterocentrally displaced meniscal fragment, especially when other characteristic signs are unremarkable or absent

  10. Factors Influencing Choice of Inguinal Hernia Repair Technique

    African Journals Online (AJOL)

    This study sought to highlight factors that may influence ... Experienced peers play a major role in training on the various repair ... Reasons influencing choice of repair technique include training ... (after appendectomy) accounting for 10 to 15% of all surgical ..... in medical school [as undergraduate students or as residents].

  11. Transvaginal Cystocele Repair by Purse-String Technique Reinforced with Three Simple Sutures: Surgical Technique and Results

    Directory of Open Access Journals (Sweden)

    Ho-Sook Song

    2012-09-01

    Full Text Available Purpose Different techniques for cystocele repair including the conventional anterior colporrhaphy and mesh technique are known. Our goal was to evaluate the anatomical success and safety of our method of transvaginal anterior vaginal wall repair by the purse-string technique reinforced with three simple additional sutures in the repair of cystocele over a 4-year follow-up period. Methods This was a retrospective review of 69 consecutive patients (grades 2 to 4 who underwent the above operations between 2001 and 2011, including their success rates as assessed by use of the Baden-Walker halfway classification system. Results Of the patients, 62 patients (98% were completely cured of cystocele and 1 patient showed grade 2 cystocele recurrence that required no further treatment. Two patients with grade 4 cystocele were completely cured. There was no vaginal erosion related to the cystocele repair. Conclusions Transvaginal anterior colporrhaphy by a purse-string technique reinforced with simple additive sutures appears to be a simple, safe, and easily performed approach in cystocele repair. There is no need for other material for reinforcement, even in high-grade cystocele, which is an advantage of our technique.

  12. Combined laparoscopic and open technique for repair of congenital abdominal hernia

    Science.gov (United States)

    Ye, Qinghuang; Chen, Yan; Zhu, Jinhui; Wang, Yuedong

    2017-01-01

    Abstract Background: Prune belly syndrome (PBS) is a rare congenital disorder among adults, and the way for repairing abdominal wall musculature has no unified standard. Materials and methods: We described combining laparoscopic and open technique in an adult male who presented with PBS. Physical examination and radiological imaging verified the case of PBS. The deficiency of abdominal wall musculature was repaired by combining laparoscopic and open technique using a double-deck complex patch. Results: The patient successfully underwent abdominal wall repair by combining laparoscopic and open technique. Postoperative recovery was uneventful, and improvement in symptom was significant in follow-up after 3, 6, 12, and 24 months. Conclusions: Combining laparoscopic and open technique for repair of deficiency of abdominal wall musculature in PBS was an exploratory way to improve life quality. PMID:29049186

  13. MRI follow-up of conservatively treated meniscal knee lesions in general practice

    NARCIS (Netherlands)

    E.H.G. Oei (Edwin); I.M. Koster (Ingrid); J.H.J. Hensen; S.S. Boks (Simone); H.P.A. Wagemakers (Harry); B.W. Koes (Bart); D. Vroegindeweij (Dammis); S.M. Bierma-Zeinstra (Sita); M.G.M. Hunink (Myriam)

    2010-01-01

    textabstractObjective: To evaluate meniscal status change on follow-up MRI after 1 year, prognostic factors and association with clinical outcome in patients with conservatively treated knee injury. Methods: We analysed 403 meniscal horns in 101 conservatively treated patients (59 male; mean age 40

  14. Bonding of human meniscal and articular cartilage with photoactive 1,8-naphthalimide dyes

    Science.gov (United States)

    Judy, Millard M.; Nosir, Hany R.; Jackson, Robert W.; Matthews, James Lester; Lewis, David E.; Utecht, Ronald E.; Yuan, Dongwu

    1996-05-01

    This study focused on meniscal cartilage repair by using the laser-activated photoactive 1,8- naphthalimide dye N,N'-bis-{6-[2-(2-(2- aminoethoxy)ethoxy)ethoxyethyl]amino-1H-benz (de)isoquinolin-1,3(2H)-dion-2- yl}-1,11-diamino-3,6,9-trioxaundecane. Harvested cadaveric human menisci were debrided and carved into strips 1 mm thick, 10 mm long, and 3 mm wide. Each strip was divided into two flaps, the surface painted with photoactive dye, the painted surfaces overlapped, the sample wrapped in Saran film, and the composite sandwiched between two glass slides at a pressure of approximately 3 kg/cm2. The sample then was transilluminated by argon ion laser light of 457.9-nm wavelength at a power density of 200 mW/cm2 with exposure times up to 5 h (3902 J/cm2 energy density). Essentially, the same procedures were performed for human femoral articular cartilage samples. Control experiments were conducted with laser irradiation alone and with dye alone. All the specimens were stored in isotonic saline solution for 2 h after irradiation to ensure hydration. The bond shear-strength was then tested and samples prepared for optical and electron transmission microscopy. Shear strength values of up to 1.8 kg/cm2 for meniscal tissues and 1.2 kg/cm2 for articular cartilaginous tissues were obtained for exposures of 3902 J/cm2. Shear strength values of approximately 0.9 kg/cm2 and 0.4 kg/cm2, respectively, for meniscus and cartilage were obtained with 459 J/cm2 exposure. Dye- and light-only controls exhibited 0 kg/cm2 shear strength values. Microscopy revealed close contact at the bonded surface in the laser-activated, dye-treated-specimens. This study shows that the laser-activated photoactive dyes have the capability of athermally bonding the meniscal and articular cartilage surfaces.

  15. Anatomic deltoid ligament repair with anchor-to-post suture reinforcement: technique tip.

    Science.gov (United States)

    Lack, William; Phisitkul, Phinit; Femino, John E

    2012-01-01

    The deltoid ligament is the primary ligamentous stabilizer of the ankle joint. Both superficial and deep components of the ligament can be disrupted with a rotational ankle fracture, chronic ankle instability, or in late stage adult acquired flatfoot deformity. The role of deltoid ligament repair in these conditions has been limited and its contribution to arthritis is largely unknown. Neglect of the deltoid ligament in the treatment of ankle injuries may be due to difficulties in diagnosis and lack of an effective method for repair. Most acute repair techniques address the superficial deltoid ligament with direct end-to-end repair, fixation through bone tunnels, or suture anchor repair of avulsion injuries. Deep deltoid ligament repair has been described using direct end-to-end repair with sutures, as well as by autograft and allograft tendon reconstruction utilizing various techniques. Newer tenodesis techniques have been described for late reconstruction of both deep and superficial components in patients with stage 4 adult acquired flatfoot deformity. We describe a technique that provides anatomic ligament-to-bone repair of the superficial and deep bundles of the deltoid ligament while reducing the talus toward the medial malleolar facet of the tibiotalar joint with anchor-to-post reinforcement of the ligamentous repair. This technique may protect and allow the horizontally oriented fibers of the deep deltoid ligament to heal with the appropriate resting length while providing immediate stability of the construct.

  16. Accuracy of 3-Tesla MR and MR arthrography in diagnosis of meniscal retear in the post-operative knee

    Energy Technology Data Exchange (ETDEWEB)

    Magee, Thomas [NSI, Merritt Island, FL (United States); University of Central Florida School of Medicine, Orlando, FL (United States)

    2014-08-15

    This study assesses the accuracy of 3-Tesla (3-T) conventional MR imaging, 3-T MR arthrography, and the combined use of conventional MR and MR arthrography in the diagnosis of meniscal retears as compared with arthroscopy. The study also assess whether there are false-negative cases in which injected contrast does not extend into the meniscus despite a meniscal retear being seen on arthroscopy. One hundred consecutive knee MR arthrograms performed on patients with previous knee surgery were reviewed retrospectively. 3-T conventional MR imaging, 3-T MR arthrography, and the combined use of conventional MR and MR arthrography were assessed for meniscal retears as compared with arthroscopy. The criterion used to diagnose a meniscal retear on MR arthrogram was injected contrast tracking into the meniscus. All patients underwent second-look arthroscopy. Seventy-four patients had conventional MR findings consistent with a meniscal retear. In 83 of the 100 patients, intraarticular contrast helped in demonstrating a retear. In ten patients, there were MR findings consistent with a meniscal retear despite intra-articular contrast not tracking into the meniscus. Ninety-four of the 100 patients had meniscal retears on second-look arthroscopy. Three-Tesla conventional MR examination was 78 % sensitive and 75 % specific, MR arthrogram examination was 88 % sensitive and 100 % specific, and the combined use of MR and MR arthrogram imaging was 98 % sensitive and 75 % specific in the diagnosis of a meniscal retear. The combined use of 3-T MR and MR arthrography allows for high sensitivity and specificity in meniscal retear detection. In some patients, intraarticular contrast will not track into a meniscal retear. When MR findings are consistent with a meniscal retear but contrast does not extend into the meniscus, a meniscal retear is likely. (orig.)

  17. MR diagnosis of meniscal tears of the knee: analysis of error patterns.

    Science.gov (United States)

    Van Dyck, Pieter; Gielen, Jan; D'Anvers, Jan; Vanhoenacker, Filip; Dossche, Lieven; Van Gestel, Jozef; Parizel, Paul M

    2007-11-01

    Despite high accuracy of magnetic resonance imaging (MRI) for diagnosing meniscal tears, MR findings do not always agree with surgical findings. We performed a blinded, retrospective study to analyze the nature and frequency of errors in the MR diagnosis of meniscal tears. Medical records of 100 consecutive patients who underwent MR and arthroscopy of the knee at our institution were reviewed. Twelve patients underwent prior meniscal surgery. Twenty-three patients had 27 discrepancies between MR and surgical findings. These were independently reviewed by two additional musculoskeletal radiologists in a double blinded fashion. Original incorrect diagnoses were categorized as either unavoidable, interpretation error or equivocal for meniscal tear. MR accuracy was 88% for the medial and 85% for the lateral meniscus. Of 27 incorrect MR diagnoses, 12 (44%) were unavoidable, 10 (37%) equivocal and 5 (19%) interpretation errors. Of the 67 medial meniscal tears, 12 (18%) were missed. Eight (67%) of these 12 were categorized as equivocal, including three postoperative menisci. Of 30 lateral tears, 12 (40%) were missed, 7 (58%) of which were categorized as unavoidable. Of these 12, 11 (92%) showed fraying of the inner edge, which was shaved at arthroscopy (n = 8) or had stable tear treated conservatively (n = 3). There were three false-positive diagnoses, all occuring in the lateral meniscus, two of which were unavoidable and one interpretation error. Of all missed lateral meniscal tears, most are unavoidable and related to confusion between what represents fraying and what represents a tear. Unavoidable false-positive diagnoses are infrequent and may be related to incomplete arthroscopic evaluation. Subtle or equivocal findings still make MR diagnosis difficult, even for experienced radiologists.

  18. Impact of type of meniscal tear on radiographic and symptomatic knee osteoarthritis

    DEFF Research Database (Denmark)

    Englund, M; Roos, Ewa M.; Lohmander, L S

    2003-01-01

    To investigate long-term radiographic and patient-relevant outcome of isolated limited meniscectomy with regard to type of meniscal tear and extent of surgical resection.......To investigate long-term radiographic and patient-relevant outcome of isolated limited meniscectomy with regard to type of meniscal tear and extent of surgical resection....

  19. Epidemiology of isolated meniscal injury and its effect on performance in athletes from the National Basketball Association.

    Science.gov (United States)

    Yeh, Peter C; Starkey, Chad; Lombardo, Stephen; Vitti, Gary; Kharrazi, F Daniel

    2012-03-01

    The current incidence and outcomes of meniscal injury have not been quantified in professional athletes. To describe the incidence, risk, amount of time lost, and effect on performance for isolated meniscal injury in athletes from the National Basketball Association (NBA). Demographic factors predicting the risk of meniscal tears and the effect of injury in return to play were also investigated. Descriptive epidemiology study. A centralized database was queried to identify meniscal injuries occurring in the NBA over 21 seasons. The frequency of injury, time lost, game exposures, and incidence, rate, and risk were calculated. The preinjury and postinjury player efficiency rating (PER) was used to identify changes in player performance. We identified 129 isolated meniscal tears in NBA athletes during a 21-season span. From this number, 77 (59.7%) involved the lateral meniscus and 52 (40.3%) the medial meniscus. Injuries occurred more frequently in games. The lateral meniscus had a statistically significant higher injury rate. Both left and right knees were equally affected. The number of days missed for lateral meniscal tears and medial meniscal tears was 43.8 ± 35.7 days and 40.9 ± 29.7 days, respectively, and was not statistically different. There was a significant inverse relationship between age and rate of lateral meniscal tears, with lateral meniscal tears more likely to occur up to age 30 years; beyond that medial meniscal tears were more common. Players with a body mass index (BMI) greater than 25 had a significantly increased risk of meniscal tears compared with players with a BMI less than 25, specifically with an increased risk of lateral meniscal tears. Twenty-five players (19.4%) did not return to play. For those who did, upon returning to competition, there was no statistical change in PER from their preinjury status, and the mean number of seasons completed was 4.1 ± 3.7 seasons. The lateral meniscus is more frequently torn than the medial meniscus

  20. Cyclic Testing of the 6-Strand Tang and Modified Lim-Tsai Flexor Tendon Repair Techniques.

    Science.gov (United States)

    Kang, Gavrielle Hui-Ying; Wong, Yoke-Rung; Lim, Rebecca Qian-Ru; Loke, Austin Mun-Kitt; Tay, Shian-Chao

    2018-03-01

    In this study, we compared the Tang repair technique with the 6-strand modified Lim-Tsai repair technique under cyclic testing conditions. Twenty fresh-frozen porcine flexor tendons were randomized into 2 groups for repair with either the modified Lim-Tsai or the Tang technique using Supramid 4-0 core sutures and Ethilon 6-0 epitendinous running suture. The repaired tendons were subjected to 2 stage cyclic loading. The survival rate and gap formation at the repair site were recorded. Tendons repaired by the Tang technique achieved an 80% survival rate. None of the modified Lim-Tsai repairs survived. The mean gap formed at the end of 1000 cycles was 1.09 mm in the Tang repairs compared with 4.15 mm in the modified Lim-Tsai repairs. The Tang repair is biomechanically stronger than the modified Lim-Tsai repair under cyclic loading. The Tang repair technique may exhibit a higher tolerance for active mobilization after surgery with less propensity for gap formation. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  1. Comparison of SPECT bone scintigraphy with MRI for diagnosis of meniscal tears

    International Nuclear Information System (INIS)

    Tahmasebi, Mohammad-naghi; Saghari, Mohsen; Moslehi, Masoud; Gholamrezanezhad, Ali

    2005-01-01

    Scintigraphy has been considered as competitive to MRI, but limited data are available on the accuracy of single photon emission tomography (SPECT) compared with MRI for the assessment of meniscal tears. Our objective was to assess the value of SPECT in comparison to MRI. Between January 2003 and March 2004, sixteen patients were studied with both modalities and the accuracy rates of SPECT scan results, and MRI findings in the diagnosis of meniscal tears were compared. Arthroscopy was the gold standard. The respective sensitivity rate, specificity rate, and positive and negative predictive accuracies of MRI were 89%, 94%, 93%, and 79% and for SPECT those were 78%, 94%, 94%, and 88%. There was good agreement on the presence or absence of tears between two modalities (κ statistic = 0.699). SPECT and MRI are both valuable imaging techniques. SPECT is a useful alternative when MRI is unavailable or unsuitable and it is beneficial when more possible accuracy is desired (such as when MRI results are either inconclusive or conflict with other clinical data)

  2. Single-row versus double-row rotator cuff repair: techniques and outcomes.

    Science.gov (United States)

    Dines, Joshua S; Bedi, Asheesh; ElAttrache, Neal S; Dines, David M

    2010-02-01

    Double-row rotator cuff repair techniques incorporate a medial and lateral row of suture anchors in the repair configuration. Biomechanical studies of double-row repair have shown increased load to failure, improved contact areas and pressures, and decreased gap formation at the healing enthesis, findings that have provided impetus for clinical studies comparing single-row with double-row repair. Clinical studies, however, have not yet demonstrated a substantial improvement over single-row repair with regard to either the degree of structural healing or functional outcomes. Although double-row repair may provide an improved mechanical environment for the healing enthesis, several confounding variables have complicated attempts to establish a definitive relationship with improved rates of healing. Appropriately powered rigorous level I studies that directly compare single-row with double-row techniques in matched tear patterns are necessary to further address these questions. These studies are needed to justify the potentially increased implant costs and surgical times associated with double-row rotator cuff repair.

  3. The relationship between prevalent medial meniscal intrasubstance signal changes and incident medial meniscal tears in women over a 1-year period assessed with 3.0 T MRI

    Energy Technology Data Exchange (ETDEWEB)

    Crema, Michel D. [Boston University School of Medicine, Department of Radiology, Quantitative Imaging Center, Boston, MA (United States); Ribeirao Preto School of Medicine, University of Sao Paulo (USP), Department of Biomechanics, Medicine and Rehabilitation of the Locomotor Apparatus, and Department of Internal Medicine, Radiology Division, Ribeirao Preto (Brazil); Institute of Diagnostic Imaging (IDI), Ribeirao Preto (Brazil); Hunter, David J. [The University of Sydney, Sydney School of Medicine, Sydney (Australia); Roemer, Frank W. [Boston University School of Medicine, Department of Radiology, Quantitative Imaging Center, Boston, MA (United States); Klinikum Augsburg, Department of Radiology, Augsburg (Germany); Li, Ling [New England Baptist Hospital, Division of Research, Boston, MA (United States); Marra, Monica D. [Boston University School of Medicine, Department of Radiology, Quantitative Imaging Center, Boston, MA (United States); Institute of Diagnostic Imaging (IDI), Ribeirao Preto (Brazil); Nogueira-Barbosa, Marcello H. [Ribeirao Preto School of Medicine, University of Sao Paulo (USP), Department of Biomechanics, Medicine and Rehabilitation of the Locomotor Apparatus, and Department of Internal Medicine, Radiology Division, Ribeirao Preto (Brazil); Hellio Le Graverand, Marie-Pierre; Wyman, Bradley T. [Pfizer Global Research and Development, New London, CT (United States); Guermazi, Ali [Boston University School of Medicine, Department of Radiology, Quantitative Imaging Center, Boston, MA (United States)

    2011-08-15

    Intrasubstance meniscal signal changes not reaching the articular surface on fast spin echo (FSE) sequences are considered to represent mucoid degeneration on MRI. The aim of this study was to evaluate the association of prevalent intrasubstance signal changes with incident tears of the medial meniscus detected on 3.0 T MRI over a 1-year period. A total of 161 women aged {>=}40 years participated in a longitudinal 1-year observational study of knee osteoarthritis. MRI (3.0 T) was performed at baseline and 12-month follow-up. The anterior horn, body, and posterior horn of the medial meniscus were scored by two experienced musculoskeletal radiologists using the Boston-Leeds Osteoarthritis Knee Score (BLOKS) system. Four grades were used to describe the meniscal morphology: grade 0 (normal), grade 1 (intrasubstance signal changes not reaching the articular surface), grade 2 (single tears), and grade 3 (complex tears and maceration). Fisher's exact test and the Cochran-Armitage trend test were performed to evaluate whether baseline intrasubstance signal changes (grade 1) predict incident meniscal tears/maceration (grades 2 and/or 3) in the same subregion of the medial meniscus, when compared to subregions without pathology as the reference group (grade 0). Medial meniscal intrasubstance signal changes at baseline did not predict tears at follow-up when evaluating the anterior and posterior horns (left-sided p-values 0.06 and 0.59, respectively). No incident tears were detected in the body. We could not demonstrate an association between prevalent medial meniscal intrasubstance signal changes with incident tears over a 1-year period. (orig.)

  4. The relationship between prevalent medial meniscal intrasubstance signal changes and incident medial meniscal tears in women over a 1-year period assessed with 3.0 T MRI

    International Nuclear Information System (INIS)

    Crema, Michel D.; Hunter, David J.; Roemer, Frank W.; Li, Ling; Marra, Monica D.; Nogueira-Barbosa, Marcello H.; Hellio Le Graverand, Marie-Pierre; Wyman, Bradley T.; Guermazi, Ali

    2011-01-01

    Intrasubstance meniscal signal changes not reaching the articular surface on fast spin echo (FSE) sequences are considered to represent mucoid degeneration on MRI. The aim of this study was to evaluate the association of prevalent intrasubstance signal changes with incident tears of the medial meniscus detected on 3.0 T MRI over a 1-year period. A total of 161 women aged ≥40 years participated in a longitudinal 1-year observational study of knee osteoarthritis. MRI (3.0 T) was performed at baseline and 12-month follow-up. The anterior horn, body, and posterior horn of the medial meniscus were scored by two experienced musculoskeletal radiologists using the Boston-Leeds Osteoarthritis Knee Score (BLOKS) system. Four grades were used to describe the meniscal morphology: grade 0 (normal), grade 1 (intrasubstance signal changes not reaching the articular surface), grade 2 (single tears), and grade 3 (complex tears and maceration). Fisher's exact test and the Cochran-Armitage trend test were performed to evaluate whether baseline intrasubstance signal changes (grade 1) predict incident meniscal tears/maceration (grades 2 and/or 3) in the same subregion of the medial meniscus, when compared to subregions without pathology as the reference group (grade 0). Medial meniscal intrasubstance signal changes at baseline did not predict tears at follow-up when evaluating the anterior and posterior horns (left-sided p-values 0.06 and 0.59, respectively). No incident tears were detected in the body. We could not demonstrate an association between prevalent medial meniscal intrasubstance signal changes with incident tears over a 1-year period. (orig.)

  5. Laboratory testing of closure cap repair techniques

    International Nuclear Information System (INIS)

    Persoff, P.; Moridis, G.; Tuck, D.M.

    1996-10-01

    Landfill design requires a low permeability closure cap as well as a low permeability liner. The Savannah River Site, in South Carolina, has approximately 85 acres of mixed waste landfills covered with compacted kaolin clay. Maintaining low permeability of the clay cap requires both that the permeability of the compacted clay itself remain low and that the integrity of the barrier be maintained. Barrier breaches typically result from penetration by roots or animals, and especially cracks caused by uneven settling or desiccation. In this study, clay layers, 0.81 m in diameter and 7.6 cm thick, were compacted in 7 lysimeters to simulate closure caps. The hydraulic conductivity of each layer was measured, and the compacted clay layers (CCL's) were cracked by drying. Then various repair techniques were applied and the effectiveness of each repair was assessed by remeasuring the hydraulic conductivity. Finally the repaired CCL was again dried and measured to determine how the repair responded to the conditions that caused the original failure. For a full report of this investigation see Persoff et al. Six repair techniques have been tested, four of which involve the use of injectable barrier liquids colloidal silica (CS) and polysiloxane (PSX) described below: (I) covering the crack with a bentonite geosynthetic clay liner (GCL), (ii) recompaction of new kaolinite at STD+3 moisture content joined to existing kaolinite that had dried and shrunk, (iii) direct injection of colloidal silica to a crack, (iv) injection of colloidal silica (CS) to wells in an overlying sand layer, (v) direct injection of polysiloxane to a crack, and (vi), injection of polysiloxane (PSX) to wells in an overlying soil layer

  6. Cartilage Degeneration, Subchondral Mineral and Meniscal Mineral Densities in Hartley and Strain 13 Guinea Pigs

    Science.gov (United States)

    Sun, Yubo; Scannell, Brian P; Honeycutt, Patrick R; Mauerhan, David R; H, James Norton; Hanley Jr, Edward N

    2015-01-01

    Osteoarthritis is a joint disease involved in articular cartilage, subchondral bone, meniscus and synovial membrane. This study sought to examine cartilage degeneration, subchondral bone mineral density (BMD) and meniscal mineral density (MD) in male Hartley, female Hartley and female strain 13 guinea pigs to determine the association of cartilage degeneration with subchondral BMD and meniscal MD. Cartilage degeneration, subchondral BMD and meniscal MD in 12 months old guinea pigs were examined with histochemistry, X-ray densitometry and calcium analysis. We found that male Hartley guinea pigs had more severe cartilage degeneration, subchondral BMD and meniscal MD than female Hartley guinea pigs, but not female strain 13 guinea pigs. Female strain 13 guinea pigs had more severe cartilage degeneration and higher subchondral BMD, but not meniscal MD, than female Hartley guinea pigs. These findings indicate that higher subchondral BMD, not meniscal MD, is associated with more severe cartilage degeneration in the guinea pigs and suggest that abnormal subchondral BMD may be a therapeutic target for OA treatment. These findings also indicate that the pathogenesis of OA in the male guinea pigs and female guinea pigs are different. Female strain 13 guinea pig may be used to study female gender-specific pathogenesis of OA. PMID:26401159

  7. Meniscal transplantation: procedures, outcomes, and rehabilitation

    Directory of Open Access Journals (Sweden)

    Young J

    2017-05-01

    Full Text Available James Young, Francois Tudor, Ahmed Mahmoud, Peter Myers Brisbane Orthopaedic & Sports Medicine Centre, Brisbane Private Hospital, Spring Hill, Brisbane, Queensland, Australia Abstract: Meniscal allograft transplantation (MAT is a possible treatment option for patients with joint pain after meniscectomy. It is necessary that the joint be aligned and stable. Current evidence shows that MAT improves pain and mechanical function in the mid to long term with patients reporting significantly improved outcomes at up to 15 years following surgery. Studies on survivorship showed up to 76% graft survival at 10 years. Recent studies have suggested a chondroprotective effect, but there is, at present, no evidence to support MAT in the prevention of osteoarthritis. This review article reported the current evidence for MAT showing support for fresh frozen, nonirradiated allografts. However, further research is required to determine the ideal indications for MAT, the optimal graft fixation method, and the safest rehabilitation protocol. Keywords: meniscus, meniscectomy, meniscal allograft transplantation

  8. A meta-analysis of clinical and radiographic outcomes of posterior horn medial meniscus root repairs.

    Science.gov (United States)

    Chung, Kyu Sung; Ha, Jeong Ku; Ra, Ho Jong; Kim, Jin Goo

    2016-05-01

    Although interest in medial meniscus posterior root tear (MMPRT) repair has increased, few case series have been reported. This meta-analysis aimed to examine the clinical and radiological effects of MMPRT repair by pooling pre- and post-operative data from case-series reports. A literature search was performed using MEDLINE/PubMed, the Cochrane Central Register of Controlled Trials, and EMBASE databases. Pre- and post-operative data were pooled to investigate the effects of MMPRT repair, including the Lysholm score improvement, meniscal extrusion (mm) reduction, progression of the Kellgren-Lawrence (K-L) grade, and cartilage status according to the Outerbridge classification. Treatment effects included paired standardized mean differences (difference in the pre- and post-operative mean outcomes divided by the standard deviation) for the Lysholm score and meniscal extrusion, as well as the pooled event rates of progression of K-L grade and cartilage status. As treatment effects, the Lysholm score increased by as much as 3.675 (P meniscus extrusion was not reduced (n.s.). The overall pooled event rates of progression of K-L grade and cartilage status were 10.6 and 17.3 % (P meniscus extrusion was not reduced. Considering the occurrence of progression of K-L grade and cartilage status, it did not prevent the progression of arthrosis completely. Based on these results, repair results in favourable outcomes for MMPRT. Meta-analysis, Level IV.

  9. A very simple technique to repair Grynfeltt-Lesshaft hernia.

    Science.gov (United States)

    Solaini, Leonardo; di Francesco, F; Gourgiotis, S; Solaini, Luciano

    2010-08-01

    A very simple technique to repair a superior lumbar hernia is described. The location of this type of hernia, also known as the Grynfeltt-Lesshaft hernia, is defined by a triangle placed in the lumbar region. An unusual case of a 67-year-old woman with a superior lumbar hernia is reported. The diagnosis was made by physical examination. The defect of the posterior abdominal wall was repaired with a polypropylene dart mesh. The patient had no evidence of recurrence at 11 months follow up. The surgical approach described in this paper is simple and easy to perform, and its result is comparable with other techniques that are much more sophisticated. No cases on the use of dart mesh to repair Grynfeltt-Lesshaft hernia have been reported by surgical journals indexed in PubMed.

  10. Advanced Inspection and Repair Welding Techniques for SCC Countermeasures

    International Nuclear Information System (INIS)

    Takagi, T.; Nishimoto, K.; Uchimoto, T.

    2012-01-01

    Feasibility studies of advanced inspection and repair welding techniques were conducted in the framework of the Nuclear and Industry Safety Agency of Japan (NISA) project on the enhancement of ageing management and maintenance of NPPs. In this paper, features of NDE methods investigated in the projects, main results of research activities and prospect of nickel based alloy weld inspection are discussed. We also make a review for the integrity and reliability evaluation techniques for repair welding of ageing plants which were intensively investigated in view of regulatory criteria, in NISA project. (author)

  11. Evolution of Autologous Chondrocyte Repair and Comparison to Other Cartilage Repair Techniques

    Directory of Open Access Journals (Sweden)

    Ashvin K. Dewan

    2014-01-01

    Full Text Available Articular cartilage defects have been addressed using microfracture, abrasion chondroplasty, or osteochondral grafting, but these strategies do not generate tissue that adequately recapitulates native cartilage. During the past 25 years, promising new strategies using assorted scaffolds and cell sources to induce chondrocyte expansion have emerged. We reviewed the evolution of autologous chondrocyte implantation and compared it to other cartilage repair techniques. Methods. We searched PubMed from 1949 to 2014 for the keywords “autologous chondrocyte implantation” (ACI and “cartilage repair” in clinical trials, meta-analyses, and review articles. We analyzed these articles, their bibliographies, our experience, and cartilage regeneration textbooks. Results. Microfracture, abrasion chondroplasty, osteochondral grafting, ACI, and autologous matrix-induced chondrogenesis are distinguishable by cell source (including chondrocytes and stem cells and associated scaffolds (natural or synthetic, hydrogels or membranes. ACI seems to be as good as, if not better than, microfracture for repairing large chondral defects in a young patient’s knee as evaluated by multiple clinical indices and the quality of regenerated tissue. Conclusion. Although there is not enough evidence to determine the best repair technique, ACI is the most established cell-based treatment for full-thickness chondral defects in young patients.

  12. MR imaging of meniscal bucket-handle tears: a review of signs and their relation to arthroscopic classification

    International Nuclear Information System (INIS)

    Aydingoez, Uestuen; Firat, Ahmet K.; Atay, Ahmet Oe.; Doral, Nedim M.

    2003-01-01

    Our objective was to review the MR imaging signs of meniscal bucket-handle tears and assess the relevance of these signs to the arthroscopic classification of displaced meniscal tears. Forty-five menisci in 42 patients who had a diagnosis of bucket-handle tear either on MR imaging or on subsequent arthroscopy (in which Dandy's classification of meniscal tears was used) were retrospectively analyzed for MR imaging findings of double posterior cruciate ligament (PCL), fragment within the intercondylar notch, absent bow tie, flipped meniscus, double-anterior horn, and disproportional posterior horn signs. Arthroscopy, which was considered as the gold standard, revealed 41 bucket-handle tears (either diagnosed or not diagnosed by MR imaging) in 38 patients (33 males, 5 females). There was a stastistically significant male preponderance for the occurrence of meniscal bucket-handle tears. Overall, sensitivity and positive predictive value of MR imaging for the detection of meniscal bucket-handle tears were calculated as 90%. Common MR imaging signs of meniscal bucket-handle tears in arthroscopically proven cases of such tears were the fragment in the notch and absent bow tie signs (98% frequency for each). Double-PCL, flipped meniscus, double-anterior horn, and disproportional posterior horn signs, however, were less common (32, 29, 29, and 27%, respectively). An arthroscopically proven bucket-handle tear was found in all patients who displayed at least three of the six MR imaging signs of meniscal bucket-handle tears. The presence of three or more MR imaging signs of meniscal bucket-handle tears is highly suggestive of this condition. (orig.)

  13. Evaluation of changes in vertical ground reaction forces as indicators of meniscal damage after transection of the cranial cruciate ligament in dogs.

    Science.gov (United States)

    Trumble, Troy N; Billinghurst, R Clark; Bendele, Alison M; McIlwraith, C Wayne

    2005-01-01

    To determine whether decreases in peak vertical force of the hind limb after transection of the cranial cruciate ligament (CrCL) would be indicative of medial meniscal damage in dogs. 39 purpose-bred adult male Walker Hounds. The right CrCL was transected arthroscopically. Force plate measurements of the right hind limb were made prior to and 2, 4, 10, and 18 weeks after transection of the CrCL. Only dogs with > or =10% decreases in peak vertical force after week 2 were considered to have potential meniscal damage. Dogs that did not have > or =10% decreases in peak vertical force at any time point after week 2 were assigned to group 1. Group 2 dogs had > or =10% decreases in peak vertical force from weeks 2 to 4 only. Group 3 and 4 dogs had > or =10% decreases in peak vertical force from weeks 4 to 10 only or from weeks 10 to 18 only, respectively. Damage to menisci and articular cartilage was graded at week 18, and grades for groups 2 to 4 were compared with those of group 1. The percentage change in peak vertical force and impulse area was significantly different in groups 2 (n = 4), 3 (4), and 4 (4) at the end of each measurement period (weeks 4, 10, and 18, respectively) than in group 1 (27). The meniscal grade for groups 2 to 4 was significantly higher than for group 1. A > or =10% decrease in peak vertical force had sensitivity of 52% and accuracy of 72% for identifying dogs with moderate to severe medial meniscal damage. In dogs with transected or ruptured CrCLs, force plate analysis can detect acute exacerbation of lameness, which may be the result of secondary meniscal damage, and provide an objective noninvasive technique that delineates the temporal pattern of medial meniscal injury.

  14. Isolated medial meniscal tear in a Border Collie.

    Science.gov (United States)

    Ridge, P A

    2006-01-01

    A three-year-old, female Border Collie was successfully treated for an isolated, torn, medial meniscus by arthroscopic meniscal tear resection. The dog returned to agility competition without recurrence of lameness.

  15. Large regional differences in incidence of arthroscopic meniscal procedures in the public and private sector in Denmark

    DEFF Research Database (Denmark)

    Hare, Kristoffer Borbjerg; Vinther, Jesper Høeg; Lohmander, L Stefan

    2015-01-01

    OBJECTIVES: A recent study reported a large increase in the number of meniscal procedures from 2000 to 2011 in Denmark. We examined the nation-wide distribution of meniscal procedures performed in the private and public sector in Denmark since different incentives may be present and the use...... of these procedures may differ from region to region. SETTING: We included data on all patients who underwent an arthroscopic meniscal procedure performed in the public or private sector in Denmark. PARTICIPANTS: Data were retrieved from the Danish National Patient Register on patients who underwent arthroscopic...... for public and private procedures for each region. RESULTS: Incidence of meniscal procedures increased at private and at public hospitals. The private sector accounted for the largest relative and absolute increase, rising from an incidence of 1 in 2000 to 98 in 2011. In 2011, the incidence of meniscal...

  16. Structural pathology is not related to patient-reported pain and function in patients undergoing meniscal surgery

    DEFF Research Database (Denmark)

    Christensen, Simon Tornbjerg; Nissen, Nis; Englund, Martin

    2017-01-01

    BACKGROUND: The relationship between meniscal tears and other joint pathologies with patient-reported symptoms is not clear. We investigated associations between structural knee pathologies identified at surgery with preoperative knee pain and function in patients undergoing arthroscopic meniscal...... of meniscal tears questionnaire, supplemented with information extracted from surgery reports. Following hypothesis-driven preselection of candidate variables, backward elimination regressions were performed to investigate associations between patient-reported outcomes and structural knee pathologies. RESULTS...... surgery. METHODS: This study included 443 patients from the Knee Arthroscopy Cohort Southern Denmark (KACS), a prospective cohort following patients 18 years or older undergoing arthroscopic meniscal surgery at 4 hospitals between 1 February 2013 and 31 January 2014. Patient-reported outcomes, including...

  17. Signs of knee osteoarthritis common in 620 patients undergoing arthroscopic surgery for meniscal tear

    DEFF Research Database (Denmark)

    Pihl, Kenneth; Englund, Martin; Lohmander, L. Stefan

    2017-01-01

    Background and purpose - Recent evidence has questioned the effect of arthroscopic knee surgery for middle-aged and older patients with degenerative meniscal tears with or without concomitant radiographic knee osteoarthritis (OA). We investigated the prevalence of early or more established knee OA...... and patients' characteristics in a cohort of patients undergoing arthroscopic surgery for a meniscal tear. Patients and methods - 641 patients assigned for arthroscopy on suspicion of meniscus tear were consecutively recruited from February 2013 through January 2015. Of these, 620 patients (mean age 49 (18...... established knee OA was present in 43% of patients undergoing knee arthroscopy for meniscal tear....

  18. Large regional differences in incidence of arthroscopic meniscal procedures in the public and private sector in Denmark.

    Science.gov (United States)

    Hare, Kristoffer Borbjerg; Vinther, Jesper Høeg; Lohmander, L Stefan; Thorlund, Jonas Bloch

    2015-02-24

    A recent study reported a large increase in the number of meniscal procedures from 2000 to 2011 in Denmark. We examined the nation-wide distribution of meniscal procedures performed in the private and public sector in Denmark since different incentives may be present and the use of these procedures may differ from region to region. We included data on all patients who underwent an arthroscopic meniscal procedure performed in the public or private sector in Denmark. Data were retrieved from the Danish National Patient Register on patients who underwent arthroscopic meniscus surgery as a primary or secondary procedure in the years 2000 to 2011. Hospital identification codes enabled linkage of performed procedures to specific hospitals. Yearly incidence of meniscal procedures per 100,000 inhabitants was calculated with 95% CIs for public and private procedures for each region. Incidence of meniscal procedures increased at private and at public hospitals. The private sector accounted for the largest relative and absolute increase, rising from an incidence of 1 in 2000 to 98 in 2011. In 2011, the incidence of meniscal procedures was three times higher in the Capital Region than in Region Zealand. Our study identified a large increase in the use of meniscal procedures in the public and private sector in Denmark. The increase was particularly conspicuous in the private sector as its proportion of procedures performed increased from 1% to 32%. Substantial regional differences were present in the incidence and trend over time of meniscal procedures. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  19. Meniscal and cruciate ligaments tears diagnosed with MR imaging versus arthroscopy

    International Nuclear Information System (INIS)

    Ziemianski, A.; Kruczynski, J.; Bruszewski, J.

    1993-01-01

    MR studies of knee joints in 37 patients were performed. The clinical diagnostics was traumatic lesions of menisci or cruciate ligaments. Arthroscopy of the knee joint was performed in 21 patients. MR showed meniscal lesion in 25 patients and anterior cruciate ligament (ACL) lesions in 18 patients. Arthroscopy showed meniscal lesions in 16 of 21 patients and ACL lesions in 11 of 21 patients. MR correlated with arthroscopy in 16 of examined menisci and 15 of 21 examined ACL. (author)

  20. Value of modern sonography in the assessment of meniscal lesions

    International Nuclear Information System (INIS)

    Wareluk, Pawel; Szopinski, Kazimierz T.

    2012-01-01

    The aim of this prospective study was to assess the accuracy of modern ultrasonography in diagnostic imaging of meniscal tears. One hundred and sixty menisci were evaluated in 80 patients (42 females, 38 males, mean age = 36.2 years, range = 16–70 years). Inclusion criteria for the study were twofold: clinical suspicion of meniscal injury and clinical indication for arthroscopy. Knee examination was performed with the Voluson 730 Expert ultrasound system (General Electric). After sonographic examination, all patients underwent arthroscopic procedures within 1–4 days. The final diagnosis of meniscal tears was taken from surgical reports. The overall sensitivity, specificity, positive predictive value and negative predictive value of sonographic examination in the assessment of meniscal tears amounted to 85.4%, 85.7%, 67.3% and 94.4%, respectively. The statistical parameters were not statistically different in medial and lateral menisci. Age, sex, body mass index (BMI), weight, physical activity, mechanism on injury, and time lapse from injury did not have a statistically significant impact on the usefulness of ultrasonography. The highest sensitivity (>90%) was obtained in medial menisci and in patients with a BMI > 25. The highest specificity (>90%) was obtained in lateral menisci, in patients after twisting injuries, in sports injuries, and in recent injuries (time lapse from the injury <1 month). The positive predictive value (PPV) of sonographic examination was higher than 90% only in recent injuries (<1 month), however, the negative predictive value of ultrasound is high, being less than 90% in males with lesions of lateral menisci and in sequelae of sports injuries

  1. Value of modern sonography in the assessment of meniscal lesions

    Energy Technology Data Exchange (ETDEWEB)

    Wareluk, Pawel, E-mail: pwareluk@wum.edu.pl [Department of Diagnostic Imaging, Second Faculty of Medicine, Medical University of Warsaw, ul. Kondratowicza 8, 03-242 Warsaw (Poland); Szopinski, Kazimierz T., E-mail: kszopinski@wum.edu.pl [Department of Dental and Maxillofacial Radiology, First Faculty of Medicine, Medical University of Warsaw, ul. Nowogrodzka 59, 02-006 Warsaw (Poland)

    2012-09-15

    The aim of this prospective study was to assess the accuracy of modern ultrasonography in diagnostic imaging of meniscal tears. One hundred and sixty menisci were evaluated in 80 patients (42 females, 38 males, mean age = 36.2 years, range = 16–70 years). Inclusion criteria for the study were twofold: clinical suspicion of meniscal injury and clinical indication for arthroscopy. Knee examination was performed with the Voluson 730 Expert ultrasound system (General Electric). After sonographic examination, all patients underwent arthroscopic procedures within 1–4 days. The final diagnosis of meniscal tears was taken from surgical reports. The overall sensitivity, specificity, positive predictive value and negative predictive value of sonographic examination in the assessment of meniscal tears amounted to 85.4%, 85.7%, 67.3% and 94.4%, respectively. The statistical parameters were not statistically different in medial and lateral menisci. Age, sex, body mass index (BMI), weight, physical activity, mechanism on injury, and time lapse from injury did not have a statistically significant impact on the usefulness of ultrasonography. The highest sensitivity (>90%) was obtained in medial menisci and in patients with a BMI > 25. The highest specificity (>90%) was obtained in lateral menisci, in patients after twisting injuries, in sports injuries, and in recent injuries (time lapse from the injury <1 month). The positive predictive value (PPV) of sonographic examination was higher than 90% only in recent injuries (<1 month), however, the negative predictive value of ultrasound is high, being less than 90% in males with lesions of lateral menisci and in sequelae of sports injuries.

  2. Association of MRI findings and expert diagnosis of symptomatic meniscal tear among middle-aged and older adults with knee pain.

    Science.gov (United States)

    Deshpande, Bhushan R; Losina, Elena; Smith, Savannah R; Martin, Scott D; Wright, R John; Katz, Jeffrey N

    2016-04-11

    Our aim was to examine the association between an expert clinician's impression of symptomatic meniscal tears and subsequent MRI in the context of middle-aged and older adults with knee pain. Patients older than 45 were eligible for this IRB-approved substudy if they had knee pain, had not undergone MRI and saw one of two orthopaedic surgeons experienced in the diagnosis of meniscal tear. The surgeon rated their confidence that the patient's symptoms were due to meniscal tear. The patient subsequently had a 1.5 or 3.0 T MRI within 6 months. We examined the association between presence of meniscal tear on MRI and the surgeon's confidence that the knee pain was due to meniscal tear using a χ(2) test for trend. Of 84 eligible patients, 63% were female, with a mean age of 64 years and a mean BMI of 27. The surgeon was confident that symptoms emanated from a tear among 39%. The prevalence of meniscal tear on MRI overall was 74%. Among subjects whose surgeon indicated high confidence that symptoms were due to meniscal tear, the prevalence was 80% (95% CI 63-90%). Similarly, the prevalence was 87% (95% CI 62-96%) among those whose surgeon had medium confidence and 64% (95% CI 48-77%) among those whose surgeon had low confidence (p = 0.12). Meniscal tears were frequently found on MRI even when an expert clinician was confident that a patient's knee symptoms were not due to a meniscal tear, indicating that providers should use MRI sparingly and cautiously to confirm or rule out the attribution of knee pain to meniscal tear.

  3. Usefulness of turbo spin-echo MR imaging in meniscal tears of the knee

    International Nuclear Information System (INIS)

    Jeong, Gun Young; Choi, Chang Lak; Chung, Jin Young; Han, Tae Il; Jang, Hong Im; Kim, Ji Min; Han, Hyun Young; Song, Mun Kab; Yang, Chang Kyu

    1998-01-01

    To evaluate the usefulness and diagnostic accuracy of turbo spin-echo(TSE) proton-density and T2-weighted images of meniscal tears of the knee. We retrospectively evaluated the sensitivity, specificity, and accuracy of TSE proton density and T2-weighted images of meniscal tears confirmed arthroscopically or surgically in 47 patients(98 menisci). The routine TSE parameters used in all patients were the dual echo sequence with sagittal proton density and T2-weighed images(4000/16, 90/5/2 [TR/effectiveTE/ETL/NEX]), and fat-suppressed coronal proton density and T2-weighted images. The chi-square test was used for statistical analysis. The sensitivity, specificity, and accuracy of TSE proton density images for the detection of meniscal tears were 93.9%, 93.8%, and 93.9%, respectively, in the medial meniscus, and 92.9%, 91.4%, and 91.8% in the lateral. On T2-weighted images the corresponding figures were 87.9%, 8%, and 89.8%, respectively, in the medial meniscus, and 64.3%, 91.4%, and 83.7% in the lateral. With regard to sensitivity and accuracy, TSE proton density images of meniscal tears were superior to TSE T2-weighted images.=20

  4. MRI diagnosis in meniscal tears: a Meta analysis

    International Nuclear Information System (INIS)

    Liu Xiaosheng; Xu Jianrong; Hua Jia; Wang Baisong

    2007-01-01

    Objective: To perform a Meta-analysis to evaluate the overall diagnostic value of magnetic resonance imaging (MRI) in patients with suspected meniscal tears. Methods: All the papers concerning the diagnosis of meniscal tears using MRI in both English and Chinese published from 1998 to 2004 had been searched and reviewed, and the studies with the arthroscopy as the gold standard were adopted as eligible. Statistical analysis was performed employing SAS 8.0. Heterogeneity of the included articles was tested, which was used to select proper effect model to calculate pooled weighted sensitivity, specificity and accuracy. Summary receiver operating characteristic (SROC) analyses were performed for tears of both menisci. Finally, subgroup analysis on magnetic field strength was performed. Results: Totally 11 studies were met the inclusion criteria with a total of 1221 patients. The pooled indexes of diagnostic performance and SROC demonstrated a high discriminatory power for detecting tears of the medial and lateral menisci. The value of TPR * for medial and lateral menisci showed no significant difference (0.90, 0.86, respectively, Z=0.11, P>0.05). Subgroup analysis demonstrated no statistically significant difference on diagnostic performance for various magnetic field strength (P>0.05). Conclusion: MRI is a highly accurate diagnostic tool for detecting tears of the medial and lateral menisci. At present, there is no evidence to ascertain that higher magnetic field strength improves discriminatory power for meniscal tears. (authors)

  5. An anatomical study of normal meniscal roots with isotropic 3D MRI at 3 T

    International Nuclear Information System (INIS)

    Ren Ahong; Zheng Zhuozhao; Shang Yao; Tian Chunyan

    2012-01-01

    Objectives: To clarify the morphological features of normal meniscal roots on magnetic resonance (MR) imaging with an isotropic 3D proton density-weighted (PDW) sequence. Materials: 3D PDW MR was performed in sixty-two patients at 3 T before knee arthroscopy. MR images of 34 normal medial menisci and 33 intact lateral menisci confirmed by arthroscopy were retrospectively evaluated. MR signals, insertion sites, dimensions and courses of four meniscal roots were recorded. Results: The anterior root of medial meniscus (ARMM) was typically hypointense, while the posterior root of medial meniscus (PRMM) and the anterior root of lateral meniscus (ARLM) were prone to be hyperintense or showing a comblike signal, and the posterior root of lateral meniscus (PRLM) was usually hypointense or comblike on PDW MR images. ARMM and PRLM had more complex and diverse insertion patterns than ARLM and PRMM. There were significant statistical differences of the lengths, widths, heights and course angles among four meniscal roots (all P < 0.001). Conclusions: The signal intensity of each meniscal root can be hypointense, hyperintense, or comblike on 3D PDW MR images. ARMM and PRLM have more complex and diverse insertion patterns than ARLM and PRMM. The dimensions and courses of four meniscal roots all differ.

  6. Evaluation of meniscal subluxation of the knee with MR imaging

    International Nuclear Information System (INIS)

    Kim, Hyun Chul; Park, Jin Gyoon; Kang, Heoung Keun; Kim, Jae Kyu; Seo, Jeong Jin; Kim, Yun Hyeon; Chung, Tae Woong

    2000-01-01

    The purpose of this study was to determine the normal meniscal position and meniscal subluxation by means of MR imaging. The normal position of the meniscus was determined by measuring the distance between the peripheral meniscal borders and the tibial plateau, as seen on coronal, sagittal and oblique MR images of 40 normal knees. For 33 abnormal knees in which outward subluxation of the meniscus from the tibial plateau was noted, the involved site, the predisposing factor, and the frequency of meniscus tearing were analyzed. In normal knees, the peripheral border of the meniscus extruded 3mm or less from the peripheral border of the tibial plateau. Among 33 abnormal knees, in which 5mm or more outward subluxation of the meniscus was seen, 19 menisci were medial and 14 were lateral. Among the 19, the body was involved in 12, the anterior horn in six, and the posterior horn in one. With regard to the 14 lateral subluxations, involvement of the posterior horn occurred in ten, of both the body and posterior horn in two, of the anterior horn in one, and of the body in one. The common predisposing factor in medial meniscus subluxation was osteoarthritis, seen in 89% of such cases, and in lateral subluxation, anterior cruciate ligament tear, which occurred in 79% of cases. Medial meniscus tear was noted in 89% of medial meniscus subluxations and lateral meniscus tear in 43% of lateral subluxations. Meniscal subluxation was easily detected by MR imaging of the knee. The common predisposing factor in medial meniscus subluxation was osteoarthritis, and in lateral meniscus subluxation, anterior cruciate ligament tear. A torn meniscus frequently co-occurred

  7. Exercise therapy versus arthroscopic partial meniscectomy for degenerative meniscal tear in middle aged patients

    DEFF Research Database (Denmark)

    Kise, Nina Jullum; Risberg, May Arna; Stensrud, Silje

    2016-01-01

    Objective To determine if exercise therapy is superior to arthroscopic partial meniscectomy for knee function in middle aged patients with degenerative meniscal tears. Design Randomised controlled superiority trial. Setting Orthopaedic departments at two public hospitals and two physiotherapy...... clinics in Norway. Participants 140 adults, mean age 49.5 years (range 35.7-59.9), with degenerative medial meniscal tear verified by magnetic resonance imaging. 96% had no definitive radiographic evidence of osteoarthritis. Interventions 12 week supervised exercise therapy alone or arthroscopic partial....... Our results should encourage clinicians and middle aged patients with degenerative meniscal tear and no definitive radiographic evidence of osteoarthritis to consider supervised exercise therapy as a treatment option. Trial registration www.clinicaltrials.gov (NCT01002794)....

  8. Exercise therapy versus arthroscopic partial meniscectomy for degenerative meniscal tear in middle aged patients

    DEFF Research Database (Denmark)

    Kise, Nina Jullum; Risberg, May Arna; Stensrud, Silje

    2016-01-01

    OBJECTIVE: To determine if exercise therapy is superior to arthroscopic partial meniscectomy for knee function in middle aged patients with degenerative meniscal tears. DESIGN: Randomised controlled superiority trial. SETTING: Orthopaedic departments at two public hospitals and two physiotherapy...... clinics in Norway. PARTICIPANTS: 140 adults, mean age 49.5 years (range 35.7-59.9), with degenerative medial meniscal tear verified by magnetic resonance imaging. 96% had no definitive radiographic evidence of osteoarthritis. INTERVENTIONS: 12 week supervised exercise therapy alone or arthroscopic partial....... Our results should encourage clinicians and middle aged patients with degenerative meniscal tear and no definitive radiographic evidence of osteoarthritis to consider supervised exercise therapy as a treatment option.Trial registration www.clinicaltrials.gov (NCT01002794)....

  9. [TECHNIQUES IN MITRAL VALVE REPAIR VIA A MINIMALLY INVASIVE APPROACH].

    Science.gov (United States)

    Ito, Toshiaki

    2016-03-01

    In mitral valve repair via a minimally invasive approach, resection of the leaflet is technically demanding compared with that in the standard approach. For resection and suture repair of the posterior leaflet, premarking of incision lines is recommended for precise resection. As an alternative to resection and suture, the leaflet-folding technique is also recommended. For correction of prolapse of the anterior leaflet, neochordae placement with the loop technique is easy to perform. Premeasurement with transesophageal echocardiography or intraoperative measurement using a replica of artificial chordae is useful to determine the appropriate length of the loops. Fine-tuning of the length of neochordae is possible by adding a secondary fixation point on the leaflet if the loop is too long. If the loop is too short, a CV5 Gore-Tex suture can be passed through the loop and loosely tied several times to stack the knots, with subsequent fixation to the edge of the leaflet. Finally, skill in the mitral valve replacement technique is necessary as a back-up for surgeons who perform minimally invasive mitral valve repair.

  10. Repair-oriented classification of aortic insufficiency: impact on surgical techniques and clinical outcomes.

    Science.gov (United States)

    Boodhwani, Munir; de Kerchove, Laurent; Glineur, David; Poncelet, Alain; Rubay, Jean; Astarci, Parla; Verhelst, Robert; Noirhomme, Philippe; El Khoury, Gébrine

    2009-02-01

    Valve repair for aortic insufficiency requires a tailored surgical approach determined by the leaflet and aortic disease. Over the past decade, we have developed a functional classification of AI, which guides repair strategy and can predict outcome. In this study, we analyze our experience with a systematic approach to aortic valve repair. From 1996 to 2007, 264 patients underwent elective aortic valve repair for aortic insufficiency (mean age - 54 +/- 16 years; 79% male). AV was tricuspid in 171 patients bicuspid in 90 and quadricuspid in 3. One hundred fifty three patients had type I dysfunction (aortic dilatation), 134 had type II (cusp prolapse), and 40 had type III (restrictive). Thirty six percent (96/264) of the patients had more than one identified mechanism. In-hospital mortality was 1.1% (3/264). Six patients experienced early repair failure; 3 underwent re-repair. Functional classification predicted the necessary repair techniques in 82-100% of patients, with adjunctive techniques being employed in up to 35% of patients. Mid-term follow up (median [interquartile range]: 47 [29-73] months) revealed a late mortality rate of 4.2% (11/261, 10 cardiac). Five year overall survival was 95 +/- 3%. Ten patients underwent aortic valve reoperation (1 re-repair). Freedoms from recurrent Al (>2+) and from AV reoperation at 5 years was 88 +/- 3% and 92 +/- 4% respectively and patients with type I (82 +/- 9%; 93 +/- 5%) or II (95 +/- 5%; 94 +/- 6%) had better outcomes compared to type III (76 +/- 17%; 84 +/- 13%). Aortic valve repair is an acceptable therapeutic option for patients with aortic insufficiency. This functional classification allows a systematic approach to the repair of Al and can help to predict the surgical techniques required as well as the durability of repair. Restrictive cusp motion (type III), due to fibrosis or calcification, is an important predictor for recurrent Al following AV repair.

  11. MRI imaging of displaced meniscal tears: Report of a case highlighting new potential pitfalls of the MRI signs

    International Nuclear Information System (INIS)

    Prasad, Abhishek; Brar, Rahat; Rana, Shaleen

    2014-01-01

    Magnetic resonance imaging (MRI) has been found to be an excellent imaging tool for meniscal injuries. Various MRI signs have been described to detect displaced meniscal injuries, specifically the bucket-handle tears. Although these signs are quite helpful in diagnosing meniscal tears, various pitfalls have also been reported for these signs. Double anterior cruciate ligament (ACL) sign refers to presence of a linear hypointense soft tissue anterior to the ACL, which represented the flipped bucket-handle tear of the meniscus. Disproportional posterior horn and flipped meniscus signs represent asymmetrically thickened horns of the menisci due to overlying displaced meniscal fragments. We report a case wherein MRI of the knee showed tear and displacement of the medial patellofemoral ligament (MPFL) and vastus medialis complex, medial collateral ligament (MCL), and posterior cruciate ligament (PCL) mimicking these signs. To our knowledge, internally displaced MPFL and MCLs have not been described as mimics for displaced meniscal fragments

  12. Discrimination of meniscal cell phenotypes using gene expression profiles

    Directory of Open Access Journals (Sweden)

    M Son

    2012-03-01

    Full Text Available The lack of quantitative and objective metrics to assess cartilage and meniscus cell phenotypes contributes to the challenges in fibrocartilage tissue engineering. Although functional assessment of the final resulting tissue is essential, initial characterization of cell sources and quantitative description of their progression towards the natural, desired cell phenotype would provide an effective tool in optimizing cell-based tissue engineering strategies. The purpose of this study was to identify quantifiable characteristics of meniscal cells and thereby find phenotypical markers that could effectively categorize cells based on their tissue of origin (cartilage, inner, middle, and outer meniscus. The combination of gene expression ratios collagen VI/collagen II, ADAMTS-5/collagen II, and collagen I/collagen II was the most effective indicator of variation among different tissue regions. We additionally demonstrate a possible application of these quantifiable metrics in evaluating the use of serially passaged chondrocytes as a possible cell source in fibrocartilage engineering. Comparing the ratios of the passaged chondrocytes and the native meniscal cells may provide direction to optimize towards the desired cell phenotype. We have thus shown that measurable markers defining the characteristics of the native meniscus can establish a standard by which different tissue engineering strategies can be objectively assessed. Such metrics could additionally be useful in exploring the different stages of meniscal degradation in osteoarthritis and provide some insight in the disease progression.

  13. Arthroscopic Double-Row Transosseous Equivalent Rotator Cuff Repair with a Knotless Self-Reinforcing Technique.

    Science.gov (United States)

    Mook, William R; Greenspoon, Joshua A; Millett, Peter J

    2016-01-01

    Rotator cuff tears are a significant cause of shoulder morbidity. Surgical techniques for repair have evolved to optimize the biologic and mechanical variables critical to tendon healing. Double-row repairs have demonstrated superior biomechanical advantages to a single-row. The preferred technique for rotator cuff repair of the senior author was reviewed and described in a step by step fashion. The final construct is a knotless double row transosseous equivalent construct. The described technique includes the advantages of a double-row construct while also offering self reinforcement, decreased risk of suture cut through, decreased risk of medial row overtensioning and tissue strangulation, improved vascularity, the efficiency of a knotless system, and no increased risk for subacromial impingement from the burden of suture knots. Arthroscopic knotless double row rotator cuff repair is a safe and effective method to repair rotator cuff tears.

  14. Middle-aged patients with an MRI-verified medial meniscal tear report symptoms commonly associated with knee osteoarthritis

    DEFF Research Database (Denmark)

    Hare, Kristoffer B.; Stefan Lohmander, L.; Kise, Nina Jullum

    2017-01-01

    Background and purpose — No consensus exists on when to perform arthroscopic partial meniscectomy in patients with a degenerative meniscal tear. Since MRI and clinical tests are not accurate in detecting a symptomatic meniscal lesion, the patient’s symptoms often play a large role when deciding...... when to perform surgery. We determined the prevalence and severity of self-reported knee symptoms in patients eligible for arthroscopic partial meniscectomy due to a degenerative meniscal tear. We investigated whether symptoms commonly considered to be related to meniscus injury were associated...... with early radiographic signs of knee osteoarthritis. Patients and methods — We included individual baseline items from the Knee injury and Osteoarthritis Outcome Score collected in 2 randomized controlled trials evaluating treatment for an MRI-verified degenerative medial meniscal tears in 199 patients aged...

  15. Sexual dysfunction after inguinal hernia repair with the Onstep versus Lichtenstein technique

    DEFF Research Database (Denmark)

    Andresen, Kristoffer; Burcharth, Jakob; Fonnes, Siv

    2017-01-01

    BACKGROUND: Sequelae after inguinal hernia repair include pain-related impairment of sexual function. Pain during intercourse can originate from the scar, scrotum, penis, or during ejaculation. The aim of this study was to investigate if the Onstep technique resulted in better results than...... the Lichtenstein technique regarding pain-related impairment of sexual function. METHODS: This study was part of the randomized ONLI trial (NCT01753219, Onstep versus Lichtenstein for inguinal hernia repair). Separate reporting of pain-related impairment of sexual function was planned before the study start......, with a separate sample size calculation. Participants were randomized to the Onstep or Lichtenstein technique for repair of their primary inguinal hernia and followed up at 6 months postoperative with the use of a questionnaire specific for pain-related impairment of sexual function. RESULTS: A total of 259...

  16. Arthroscopic Double-Row Transosseous Equivalent Rotator Cuff Repair with a Knotless Self-Reinforcing Technique

    OpenAIRE

    Mook, William R.; Greenspoon, Joshua A.; Millett, Peter J.

    2016-01-01

    Background: Rotator cuff tears are a significant cause of shoulder morbidity. Surgical techniques for repair have evolved to optimize the biologic and mechanical variables critical to tendon healing. Double-row repairs have demonstrated superior biomechanical advantages to a single-row. Methods: The preferred technique for rotator cuff repair of the senior author was reviewed and described in a step by step fashion. The final construct is a knotless double row transosseous equivalent construc...

  17. Trajectory of self-reported pain and function and knee extensor muscle strength in young patients undergoing arthroscopic surgery for meniscal tears

    DEFF Research Database (Denmark)

    Thorlund, Jonas Bloch; Østengaard, Lasse; Cardy, Nathan

    2017-01-01

    . PATIENTS AND INTERVENTION: People aged 30 years or younger undergoing surgery for a meniscal tear. OUTCOMES: and comparator: (1) Self-reported pain and function in patients undergoing meniscal surgery compared to a non-operative control group (2). Knee extensor strength in the leg undergoing surgery...... the trajectory of self-reported pain and function in patients undergoing arthroscopic surgery compared with non-operative treatments for young patients with meniscal tears. Knee extensor strength seemed to be impaired up to 12 months after surgery in young patients undergoing surgery for meniscal tears...

  18. Sportsmen’s Groin—Diagnostic Approach and Treatment With the Minimal Repair Technique

    Science.gov (United States)

    Muschaweck, Ulrike; Berger, Luise Masami

    2010-01-01

    Context: Sportsmen’s groin, also called sports hernia and Gilmore groin, is one of the most frequent sports injuries in athletes and may place an athletic career at risk. It presents with acute or chronic groin pain exacerbated with physical activity. So far, there is little consensus regarding pathogenesis, diagnostic criteria, or treatment. There have been various attempts to explain the cause of the groin pain. The assumption is that a circumscribed weakness in the posterior wall of the inguinal canal, which leads to a localized bulge, induces a compression of the genital branch of the genitofemoral nerve, considered responsible for the symptoms. Methods: The authors developed an innovative open suture repair—the Minimal Repair technique—to fit the needs of professional athletes. With this technique, the circumscribed weakness of the posterior wall of the inguinal canal is repaired by an elastic suture; the compression on the nerve is abolished, and the cause of the pain is removed. In contrast with that of common open suture repairs, the defect of the posterior wall is not enlarged, the suture is nearly tension free, and the patient can return to full training and athletic activity within a shorter time. The outcome of patients undergoing operations with the Minimal Repair technique was compared with that of commonly used surgical procedures. Results: The following advantages of the Minimal Repair technique were found: no insertion of prosthetic mesh, no general anesthesia required, less traumatization, and lower risk of severe complications with equal or even faster convalescence. In 2009, a prospective cohort of 129 patients resumed training in 7 days and experienced complete pain relief in an average of 14 days. Professional athletes (67%) returned to full activity in 14 days (median). Conclusion: The Minimal Repair technique is an effective and safe way to treat sportsmen’s groin. PMID:23015941

  19. The global percutaneous shuttling technique tip for arthroscopic rotator cuff repair

    Directory of Open Access Journals (Sweden)

    Bryan G. Vopat

    2014-05-01

    Full Text Available Most arthroscopic rotator cuff repairs utilize suture passing devices placed through arthro- scopic cannulas. These devices are limited by the size of the passing device where the suture is passed through the tendon. An alternative technique has been used in the senior author’s practice for the past ten years, where sutures are placed through the rotator cuff tendon using percutaneous passing devices. This technique, dubbed the global percutaneous shuttling technique of rotator cuff repair, affords the placement of sutures from nearly any angle and location in the shoulder, and has the potential advantage of larger suture bites through the tendon edge. These advantages may increase the area of tendon available to compress to the rotator cuff footprint and improve tendon healing and outcomes. The aim of this study is to describe the global percutaneous shuttling (GPS technique and report our results using this method. The GPS technique can be used for any full thickness rotator cuff tear and is particularly useful for massive cuff tears with poor tissue quality. We recently followed up 22 patients with an average follow up of 32 months to validate its usefulness. American Shoulder and Elbow Surgeons scores improved significantly from 37 preoperatively to 90 postoperatively (P<0.0001. This data supports the use of the GPS technique for arthroscopic rotator cuff repair. Further biomechanical studies are currently being performed to assess the improvements in tendon footprint area with this technique.

  20. Exploration Challenges: Transferring Ground Repair Techniques to Space Flight Application

    Science.gov (United States)

    McLemore, Carole A.; Kennedy, James P.; Rose, Frederick A.; Evans, Brian W.

    2007-01-01

    Fulfilling NASA's Vision for Space Exploration will demand an extended presence in space at distances from our home planet that exceed our current experience in space logistics and maintenance. The ability to perform repairs in lieu of the customary Orbital Replacement Unit (ORU) process where a faulty part is replaced will be elevated from contingency to routine to sustain operations. The use and cost effectiveness of field repairs for ground based operations in industry and the military have advanced with the development of technology in new materials, new repair techniques and new equipment. The unique environments, accessibility constraints and Extra Vehicular Activity (EVA) issues of space operations will require extensive assessment and evolution of these technologies to provide an equivalent and expected level of assurance to mission success. Challenges include the necessity of changes in design philosophy and policy, extremes in thermal cycling, disruptive forces (such as static charge and wind entrainment) on developed methods for control of materials, dramatically increased volatility of chemicals for cleaning and other compounds due to extremely low pressures, the limits imposed on dexterity and maneuverability by current EVA equipment and practices, and the necessity of unique verification methodology. This paper describes these challenges in and discusses the effects on the established ground techniques for repair. The paper also describes the leading repair methodology candidates and their beneficial attributes for resolving these issues with the evolution of technology.

  1. Clinical outcomes and repair integrity after arthroscopic full-thickness rotator cuff repair: suture-bridge versus double-row modified Mason-Allen technique.

    Science.gov (United States)

    Lee, Kwang Won; Yang, Dae Suk; Lee, Gyu Sang; Ma, Chang Hyun; Choy, Won Sik

    2018-05-23

    This retrospective study compared the clinical and radiologic outcomes of patients who underwent arthroscopic rotator cuff repairs by the suture-bridge and double-row modified Mason-Allen techniques. From January 2012 to May 2013, 76 consecutive cases of full-thickness rotator cuff tear, 1 to 4 cm in the sagittal plane, for which arthroscopic rotator cuff repair was performed, were included. The suture-bridge technique was used in 37 consecutive shoulders; and the double-row modified Mason-Allen technique, in 39 consecutive shoulders. Clinical outcomes at a minimum of 2 years (mean, 35.7 months) were evaluated postoperatively using the visual analog scale; University of California, Los Angeles Shoulder Scale; American Shoulder and Elbow Surgeons Subjective Shoulder Scale; and Constant score. Postoperative cuff integrity was evaluated at a mean of 17.7 months by magnetic resonance imaging. At the final follow-up, the clinical outcomes improved in both groups (all P  .05). The retear rate was 18.9% in the shoulders subjected to suture-bridge repair and 12.8% in the double-row modified Mason-Allen group; the difference was not significant (P = .361). Despite the presence of fewer suture anchors, the patients who underwent double-row modified Mason-Allen repair had comparable shoulder functional outcomes and a comparable retear rate with those who underwent suture-bridge repair. Therefore, the double-row modified Mason-Allen repair technique can be considered an effective treatment for patients with medium- to large-sized full-thickness rotator cuff tears. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  2. Patch-augmented rotator cuff repair: influence of the patch fixation technique on primary biomechanical stability.

    Science.gov (United States)

    Jung, Christian; Spreiter, Gregor; Audigé, Laurent; Ferguson, Stephen J; Flury, Matthias

    2016-05-01

    There is an ongoing debate about the potential of patch augmentation to improve biomechanical stability and healing associated with rotator cuff repair. The biomechanical properties of three different patch-augmented rotator cuff repair techniques were assessed in vitro and compared with a standard repair. Dermal collagen patch augmentation may increase the primary stability and strength of the repaired tendon in vitro, depending on the technique used for patch application. Forty cadaveric sheep shoulders with dissected infraspinatus tendons were randomized into four groups (n = 10/group) for tendon repair using a knotless double-row suture anchor technique. A xenologous dermal extracellular matrix patch was used for augmentation in the three test groups using an "integrated", "cover", or "hybrid" technique. Tendons were preconditioned, cyclically loaded from 10 to 30 N at 1 Hz, and then loaded monotonically to failure. Biomechanical properties and the mode of failure were evaluated. Patch augmentation significantly increased the maximum load at failure by 61 % in the "cover" technique test group (225.8 N) and 51 % in the "hybrid" technique test group (211.4 N) compared with the non-augmented control group (140.2 N) (P ≤ 0.015). For the test group with "integrated" patch augmentation, the load at failure was 28 % lower (101.6 N) compared with the control group (P = 0.043). There was no significant difference in initial and linear stiffness among the four experimental groups. The most common mode of failure was tendon pullout. No anchor dislocation, patch disruption or knot breakage was observed. Additional patch augmentation with a collagen patch influences the biomechanical properties of a rotator cuff repair in a cadaveric sheep model. Primary repair stability can be significantly improved depending on the augmentation technique.

  3. Radar rainfall image repair techniques

    Directory of Open Access Journals (Sweden)

    Stephen M. Wesson

    2004-01-01

    Full Text Available There are various quality problems associated with radar rainfall data viewed in images that include ground clutter, beam blocking and anomalous propagation, to name a few. To obtain the best rainfall estimate possible, techniques for removing ground clutter (non-meteorological echoes that influence radar data quality on 2-D radar rainfall image data sets are presented here. These techniques concentrate on repairing the images in both a computationally fast and accurate manner, and are nearest neighbour techniques of two sub-types: Individual Target and Border Tracing. The contaminated data is estimated through Kriging, considered the optimal technique for the spatial interpolation of Gaussian data, where the 'screening effect' that occurs with the Kriging weighting distribution around target points is exploited to ensure computational efficiency. Matrix rank reduction techniques in combination with Singular Value Decomposition (SVD are also suggested for finding an efficient solution to the Kriging Equations which can cope with near singular systems. Rainfall estimation at ground level from radar rainfall volume scan data is of interest and importance in earth bound applications such as hydrology and agriculture. As an extension of the above, Ordinary Kriging is applied to three-dimensional radar rainfall data to estimate rainfall rate at ground level. Keywords: ground clutter, data infilling, Ordinary Kriging, nearest neighbours, Singular Value Decomposition, border tracing, computation time, ground level rainfall estimation

  4. Controlled, all-position, butterbead-temperbead welding technique for nuclear repairs

    International Nuclear Information System (INIS)

    Clark, J.N.; Lambert, J.A.

    1986-01-01

    Sections III and XI of the ASME boiler and pressure vessel code describe a half-bead temper repair welding technique specifically designed for in-service BWR and PWR repair applications without postweld heat treatment. The method relies on deposition of two layers of weld beads. Prior to deposition of the second layer, half the first layer is ground away. As a result, the first layer HAZ is tempered or retransformed by the second layer heat input. It is on the basis of this tempering that a concession is granted to omit postweld heat treatment. The grinding stage is difficult to control, time consuming, and can involve long exposure of personnel to a radioactive environment. Consequently, there has been pressure to find a viable alternative to the half-bead technique. Much interest has been shown in the butterbead-temperbead technique, which is essentially the CEGB two-layer HAZ refinement technique. This does not require grinding of the first layer and achieves HAZ retransformation by increasing the heat input of the second layer. The elimination of the grinding stage considerably reduces repair time and, consequently, radiation exposure. The method has now been included as an acceptable alternative to the half-bead technique in section XI of the ASME code. The CEGB method has been used successfully in the U.K. power industry, mainly for prevention of stress relief cracking, but also to improve HAZ toughness for low temperature service. Two-layer HAZ refinement is achieved by retransformation of the first layer HAZ by the thermal field of the second layer

  5. Repair of lesser tuberosity osteotomy for shoulder arthroplasty: biomechanical evaluation of the Backpack and Dual Row techniques.

    Science.gov (United States)

    Heckman, Daniel S; Hoover, Stephen A; Weinhold, Paul S; Spang, Jeffrey T; Creighton, R Alexander

    2011-04-01

    Subscapularis dysfunction following total shoulder arthroplasty can result in permanent loss of function. The lesser tuberosity osteotomy (LTO) has been proposed as a method which utilizes bone-to-bone healing to improve subscapularis function. This study evaluates the biomechanical properties of two described techniques for LTO repair. We hypothesized that a Dual Row repair would be stronger and demonstrate less cyclic displacement than a Backpack repair. Ten matched pairs of cadaveric humeri were dissected, leaving the subscapularis intact, and a lesser tuberosity osteotomy was performed. Matched shoulders were randomized to either a Backpack repair or a Dual Row repair. Repairs were subjected to cyclic loading to 180 N for 500 cycles, followed by ramp-up loading to ultimate failure. Clinical failure was defined as displacement >5 mm after 500 cycles. Displacement after 500 cycles was significantly greater for the Backpack repair (6.9 mm) than for the Dual Row repair (4.6 mm) (P = .007). Most displacement occurred on the first cycle (Backpack, 4.6 mm; Dual Row, 2.1 mm) (P Row repair (3/10). Ultimate tensile strength was significantly greater for the Dual Row repair (632.3 N) than for the Backpack repair (510.9 N) (P = .01). The Dual Row technique is significantly stronger and demonstrates less cyclic displacement than the Backpack technique. Clinical studies are needed to determine the impact of LTO repair technique on subscapularis function following shoulder arthroplasty. Copyright © 2011. Published by Mosby, Inc.

  6. Meniscal position on routine MR imaging of the knee

    International Nuclear Information System (INIS)

    Miller, T.T.; Staron, R.B.; Feldman, F.; Cepel, E.

    1997-01-01

    Objective. To determine the prevalence of meniscal protrusion (i.e. location of the outer edge of a meniscus beyond the tibial articular surface), and to determine its relationship with internal derangement, joint effusion, and degenerative arthropathy. Design and patients. Sagittal and coronal MR images of 111 abnormal and 46 normal knees were evaluated for the presence of meniscal protrusion. We set 25% as the minimum amount of displacement considered abnormal because this was the smallest amount of displacement we could confidently discern. Presence of meniscal tear, anterior cruciate ligament (ACL) injury, joint effusion, or osteophytosis was also recorded. Results and conclusion. Normal examinations demonstrated protrusion of the medial meniscus in 6.5% of sagittal images and 15% of coronal images, and of the lateral meniscus in 2% and 13%, respectively. Fisher's exact test demonstrated a statistically significant difference between the normal and abnormal groups for the medial meniscus on both sagittal (P 0.2). A protruding medial meniscus was associated with effusion and osteophytosis (P 0.1). Posterior protrusion of the lateral meniscus was only associated with ACL injury (P<0.0001); protruding anterior horns and bodies of lateral menisci were not associated with any of the four abnormalities. It is concluded that the medial meniscus may occasionally protrude more than 25% of its width, but protrusion is more often due to effusion and osteophytes. Protrusion of the posterior horn of the lateral meniscus is associated with ACL insufficiency, while protrusion of the body and anterior horn of the lateral meniscus is a normal variant. (orig.). With 4 figs

  7. Comparison of CT and MRI in patients with tibial plateau fracture: can CT findings predict ligament tear or meniscal injury?

    International Nuclear Information System (INIS)

    Mui, Leonora W.; Engelsohn, Eliyahu; Umans, Hilary

    2007-01-01

    (1) To determine the accuracy of computed tomography (CT) in the evaluation of ligament tear and avulsion in patients with tibial plateau fracture. (2) To evaluate whether the presence or severity of fracture gap and articular depression can predict meniscal injury. A fellowship-trained musculoskeletal radiologist retrospectively reviewed knee CT and MRI examinations of 41 consecutive patients presenting to a level 1 trauma center with tibial plateau fractures. Fracture gap, articular depression, ligament tear and footprint avulsions were assessed on CT examinations. The MRI studies were examined for osseous and soft tissue injuries, including meniscal tear, meniscal displacement, ligament tear, and ligament avulsion. CT demonstrated torn ligaments with 80% sensitivity and 98% specificity. Only 2% of ligaments deemed intact on careful CT evaluation had partial or complete tears on MRI. Although the degree of fracture gap and articular depression was significantly greater in patients with meniscal injury compared with those without meniscal injury, ROC analysis demonstrated no clear threshold for gap or depression that yielded a combination of high sensitivity and specificity. In the acute setting, CT offers high sensitivity and specificity for depicting osseous avulsions, as well as high negative predictive value for excluding ligament injury. However, MRI remains necessary for the preoperative detection of meniscal injury. (orig.)

  8. Meniscectomy: indications, procedure, outcomes, and rehabilitation

    Directory of Open Access Journals (Sweden)

    Anetzberger H

    2013-12-01

    Full Text Available Hermann Anetzberger,1 Christof Birkenmaier,2 Stephan Lorenz3 1Orthopädische Gemeinschaftspraxis am OEZ, Munich, Germany; 2Department of Orthopedics, Ludwig-Maximilian-University Munich, Munich, Germany; 3Department of Orthopedic Sports Medicine, Technical University of Munich, Klinikum rechts der Isar, Munich, Germany Abstract: Meniscal injuries are among the most frequent reasons for knee problems. The goal of this manuscript is to review the biomechanical relevance of the human knee's menisci in relation to surgical indications, surgical techniques, rehabilitation, and outcomes. In order to identify the relevant literature, we performed a PubMed search for the years ranging from 1980–2013 using the following search terms: meniscus; biomechanical function; meniscectomy; meniscal repair; and clinical outcome. The meniscus helps to distribute the forces between the tibial and femoral articular cartilage layers in a load-sharing capacity. Meniscus damage or meniscectomy intuitively leads to an overloading of the cartilage and, hence, to the development of osteoarthrosis. Precise knowledge of meniscal shape and function, of the type of injury, of surgical techniques, as well as of postsurgical rehabilitative care are of decisive importance for an individually-adjusted treatment strategy. Other underlying coexisting knee pathologies also need to be considered. The diagnosis of a meniscal injury is based upon clinical history, physical examination, and imaging studies. The treatment of a meniscal lesion includes conservative, as well as operative, procedures. The goals of surgery are to reduce pain and disability, as well as to preserve meniscal function without causing additional cartilage damage. The resection of meniscal tissue should be restricted to as much as is necessary, and as little as is reasonably possible. Postoperative rehabilitation serves the purpose of improving functional deficits and pain, as well as of restoring a good range of

  9. Evaluation of footprint contact area and pressure using a triple-row modification of the suture-bridge technique for rotator cuff repair.

    Science.gov (United States)

    Ostrander, Roger V; McKinney, Bart I

    2012-10-01

    Studies suggest that arthroscopic repair techniques may have high recurrence rates for larger rotator cuff tears. A more anatomic repair may improve the success rate when performing arthroscopic rotator cuff repair. We hypothesized that a triple-row modification of the suture-bridge technique for rotator cuff repair would result in significantly more footprint contact area and pressure between the rotator cuff and the humeral tuberosity. Eighteen ovine infraspinatus tendons were repaired using 1 of 3 simulated arthroscopic techniques: a double-row repair, the suture-bridge technique, and a triple-row repair. The triple-row repair technique is a modification of the suture-bridge technique that uses an additional reducing anchor between the medial and lateral rows. Six samples were tested per group. Pressure-indicating film was used to measure the footprint contact area and pressure after each repair. The triple-row repair resulted in significantly more rotator cuff footprint contact area and contact pressure compared with the double-row technique and the standard suture-bridge technique. No statistical difference in contact area or contact pressure was found between the double-row technique and the suture-bridge technique. The triple-row technique for rotator cuff repair results in significantly more footprint contact area and contact pressure compared with the double-row and standard suture-bridge techniques. This more anatomic repair may improve the healing rate when performing arthroscopic rotator cuff repair. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  10. The association between reduced knee joint proprioception and medial meniscal abnormalities using MRI in knee osteoarthritis: results from the Amsterdam osteoarthritis cohort.

    Science.gov (United States)

    van der Esch, M; Knoop, J; Hunter, D J; Klein, J-P; van der Leeden, M; Knol, D L; Reiding, D; Voorneman, R E; Gerritsen, M; Roorda, L D; Lems, W F; Dekker, J

    2013-05-01

    Osteoarthritis (OA) of the knee is characterized by pain and activity limitations. In knee OA, proprioceptive accuracy is reduced and might be associated with pain and activity limitations. Although causes of reduced proprioceptive accuracy are divergent, medial meniscal abnormalities, which are highly prevalent in knee OA, have been suggested to play an important role. No study has focussed on the association between proprioceptive accuracy and meniscal abnormalities in knee OA. To explore the association between reduced proprioceptive accuracy and medial meniscal abnormalities in a clinical sample of knee OA subjects. Cross-sectional study in 105 subjects with knee OA. Knee proprioceptive accuracy was assessed by determining the joint motion detection threshold in the knee extension direction. The knee was imaged with a 3.0 T magnetic resonance (MR) scanner. Number of regions with medial meniscal abnormalities and the extent of abnormality in the anterior and posterior horn and body were scored according to the Boston-Leeds Osteoarthritis Knee Score (BLOKS) method. Multiple regression analyzes were used to examine whether reduced proprioceptive accuracy was associated with medial meniscal abnormalities in knee OA subjects. Mean proprioceptive accuracy was 2.9° ± 1.9°. Magnetic resonance imaging (MRI)-detected medial meniscal abnormalities were found in the anterior horn (78%), body (80%) and posterior horn (90%). Reduced proprioceptive accuracy was associated with both the number of regions with meniscal abnormalities (P knee complaints. This is the first study showing that reduced proprioceptive accuracy is associated with medial meniscal abnormalities in knee OA. The study highlights the importance of meniscal abnormalities in understanding reduced proprioceptive accuracy in persons with knee OA. Copyright © 2013 Osteoarthritis Research Society International. All rights reserved.

  11. One-Step Cartilage Repair Technique as a Next Generation of Cell Therapy for Cartilage Defects: Biological Characteristics, Preclinical Application, Surgical Techniques, and Clinical Developments.

    Science.gov (United States)

    Zhang, Chi; Cai, You-Zhi; Lin, Xiang-Jin

    2016-07-01

    To provide a comprehensive overview of the basic science rationale, surgical technique, and clinical outcomes of 1-step cartilage repair technique used as a treatment strategy for cartilage defects. A systematic review was performed in the main medical databases to evaluate the several studies concerning 1-step procedures for cartilage repair. The characteristics of cell-seed scaffolds, behavior of cells seeded into scaffolds, and surgical techniques were also discussed. Clinical outcomes and quality of repaired tissue were assessed using several standardized outcome assessment tools, magnetic resonance imaging scans, and biopsy histology. One-step cartilage repair could be divided into 2 types: chondrocyte-matrix complex (CMC) and autologous matrix-induced chondrogenesis (AMIC), both of which allow a simplified surgical approach. Studies with Level IV evidence have shown that 1-step cartilage repair techniques could significantly relieve symptoms and improve functional assessment (P studies clearly showed hyaline-like cartilage tissue in biopsy tissues by second-look arthroscopy. The 1-step cartilage repair technique, with its potential for effective, homogeneous distribution of chondrocytes and multipotent stem cells on the surface of the cartilage defect, is able to regenerate hyaline-like cartilage tissue, and it could be applied to cartilage repair by arthroscopy. Level IV, systematic review of Level II and IV studies. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  12. A barbed suture repair for flexor tendons: a novel technique with no exposed barbs.

    Science.gov (United States)

    Joyce, Cormac W; Sugrue, Conor; Chan, Jeffrey C; Delgado, Luis; Zeugolis, Dimitrios; Carroll, Seam M; Kelly, Jack L

    2014-10-01

    Barbed suture technology has shown promise in flexor tendon repairs, as there is an even distribution of load and the need for a knot is eliminated. We propose that a quick and simple, novel, barbed technique without any exposed barbs on the tendon surface has comparable strength and a smaller cross-sectional area at the repair site than traditional methods of repair. Forty porcine flexor tendons were randomized to polybutester 4-strand barbed repair or to 4-strand Adelaide monofilament repair. The cross-sectional area was measured before and after repair. Biomechanical testing was carried out and 2-mm gap formation force, ultimate strength of repair, and method of failure were recorded. The mean ultimate strength of the barbed repairs was 54.51 ± 17.9 while that of the Adelaide repairs was 53.17 ± 16.35. The mean 2-mm gap formation force for the barbed group was 44.71 ± 17.86 whereas that of the Adelaide group was 20.25 ± 4.99. The postrepair percentage change in cross-sectional area at the repair site for the Adelaide group and barbed group was 12.0 ± 2.3 and 4.6 ± 2.8, respectively. We demonstrated that a 4-strand knotless, barbed method attained comparable strength to that of the traditional Adelaide repair technique. The barbed method had a significantly reduced cross-sectional area at the repair site compared with the Adelaide group. The 2-mm gap formation force was less in the barbed group than the Adelaide group. Barbed repairs show promise for tendon repairs; this simple method warrants further study in an animal model.

  13. T1-weighted vs. short-TE-long-TR images. Usefulness for knee MR examinations of ligament and meniscal lesions

    International Nuclear Information System (INIS)

    Endo, Hideho; Wada, Mitsuyoshi; Shiotani, Seiji; Niitsu, Mamoru; Itai, Yuji

    2000-01-01

    The purpose of this study was to compare short-TE-long-TR images with T1-weighed images in knee MR examinations. Sagittal MR images of the knee were obtained in 31 patients with knee pain. T1-weighted images were obtained by the spin-echo technique (TR/TE =350/15), and short-TE-long-TR images by fast spin-echo (TR/TE =1300/15) with an echo-train length of 5. Contrast-to-noise-ratios (CNRs) of the anterior cruciate ligament and synovial space, meniscus and articular cartilage, and meniscal lesion and normal meniscus were compared between short-TE-long-TR images and T1-weighted images. On each of the three examinations, short-TE-long-TR images provided significantly higher CNRs than T1-weighted images. It was concluded that short-TE-long-TR images can be a useful alternative to T1-weighted images in evaluating the anterior cruciate ligament and meniscal lesions. (author)

  14. T1-weighted vs. short-TE-long-TR images. Usefulness for knee MR examinations of ligament and meniscal lesions

    Energy Technology Data Exchange (ETDEWEB)

    Endo, Hideho; Wada, Mitsuyoshi; Shiotani, Seiji [Tsukuba Medical Center Hospital, Ibaraki (Japan); Niitsu, Mamoru; Itai, Yuji

    2000-11-01

    The purpose of this study was to compare short-TE-long-TR images with T1-weighed images in knee MR examinations. Sagittal MR images of the knee were obtained in 31 patients with knee pain. T1-weighted images were obtained by the spin-echo technique (TR/TE =350/15), and short-TE-long-TR images by fast spin-echo (TR/TE =1300/15) with an echo-train length of 5. Contrast-to-noise-ratios (CNRs) of the anterior cruciate ligament and synovial space, meniscus and articular cartilage, and meniscal lesion and normal meniscus were compared between short-TE-long-TR images and T1-weighted images. On each of the three examinations, short-TE-long-TR images provided significantly higher CNRs than T1-weighted images. It was concluded that short-TE-long-TR images can be a useful alternative to T1-weighted images in evaluating the anterior cruciate ligament and meniscal lesions. (author)

  15. A Cohort Study on Meniscal Lesions among Airport Baggage Handlers

    DEFF Research Database (Denmark)

    Mikkelsen, Sigurd; Brauer, Charlotte; Pedersen, Ellen Bøtker

    2016-01-01

    socioeconomic background and less knee-straining work. Baggage handlers lifted suitcases with an average weight of approximately 15 kg, in total approximately five tonnes during a 9-hour workday. The cohort was followed in the National Patient Register and Civil Registration System. The outcome was a first time......Meniscal lesions are common and may contribute to the development of knee arthrosis. A few case-control and cross-sectional studies have identified knee-straining work as risk factors for meniscal lesions, but exposure-response relations and the role of specific exposures are uncertain...... of unskilled men employed at Copenhagen Airport or in other companies in the metropolitan Copenhagen area from 1990 to 2012 (the Copenhagen Airport Cohort). The cohort at risk included 3,307 airport baggage handlers with heavy lifting and kneeling or squatting work tasks and 63,934 referents with a similar...

  16. Human meniscal proteoglycan metabolism in long-term tissue culture

    NARCIS (Netherlands)

    Verbruggen, G.; Verdonk, R.; Veys, E. M.; van Daele, P.; de Smet, P.; van den Abbeele, K.; Claus, B.; Baeten, D.

    1996-01-01

    For the purpose of human meniscal allografting, menisci have been maintained viable in in vitro culture. The influence of long-term tissue culture on the extracellular matrix metabolism of the meniscus has been studied. Fetal calf serum (FCS) was used as a supplement for the growth factors necessary

  17. Magnetic resonance imaging of meniscal and anterior cruciate ligament injuries of the knee

    International Nuclear Information System (INIS)

    Kreitner, K.F.; Herrig, A.; Grebe, P.; Runkel, M.; Regentrop, H.J.

    1998-01-01

    To categorise discrepancies in findings of the menisci and anterior cruciate ligament (ACL) between arthroscopy and MRI. Materials and methods: The MRIs of 236 patients were retrospectively analysed by an experienced radiologist without knowledge of clinical and/for operative findings. Discrepancies in arthroscopic findings were reevaluated together with the arthroscopist to determine their cause of error. Results: The diagnostic accuracies for injuries of the medial and lateral meniscus and the ACL were 92.4%, 92.4%, and 94.1%. respectively. For the menisci, causes for discrepancies in findings (n=31) were: overinterpretation of central signal intensities with contact to the meniscal surface but without disturbance of the meniscal contour as a tear (n=12), insufficient arthroscopie evaluation of the knee joint (n=11), overlooked tears on MR imaging (n=6), misinterpretation of normal anatomic structures (n=1), ''magic angle'' phenomenon (n=1), and missed tears at MRI (n=1). Causes for discrepancies for the ACL (n=18) were: nearly complete versus complete rupture either at MRI or arthroscopy and vice versa (n=9), insufficient arthroscopic evaluation (n=6), insufficient MRI technique (n=2), and overlooked tear on MR imaging (n=1). Conclusions: Discrepant findings between MRI and arthroscopy may be also due to an insufficient arthroscopic evaluation in clinical routine. The close cooperation between surgeons and radiologists improves the understanding of the methods of each other. (orig.) [de

  18. A Barbed Suture Repair For Flexor Tendons: A Novel Technique With No Exposed Barbs

    Directory of Open Access Journals (Sweden)

    Cormac W. Joyce, MB BCh

    2014-10-01

    Conclusions: We demonstrated that a 4-strand knotless, barbed method attained comparable strength to that of the traditional Adelaide repair technique. The barbed method had a significantly reduced cross-sectional area at the repair site compared with the Adelaide group. The 2-mm gap formation force was less in the barbed group than the Adelaide group. Barbed repairs show promise for tendon repairs; this simple method warrants further study in an animal model.

  19. [Plug-technique for umbilical hernia repair in the adult].

    Science.gov (United States)

    Brancato, G; Privitera, A; Gandolfo, L; Donati, M; Caglià, P

    2002-02-01

    Umbilical hernia represents 6% of all abdominal wall hernias in the adult. Surgical repair should always be carried out due to possible occurrence of complications. Aim of this paper is to evaluate the efficacy of the plug-technique. From October 1995 to April 2000, the authors performed 21 operations for acquired umbilical hernia with a defect smaller than 4 cm. Local anesthesia was used and a light intravenous sedation added in particularly anxious patients. The repair was achieved by insertion of a polypropylene dart plug sutured to the margins of the hernial defect. All patients were up and about straightaway and were discharged within 24 hours of surgery. Postoperative pain was mild and required hospital analgesia in only 19% of cases and domiciliary analgesia in 24%. During a follow-up ranging from 6 to 60 months (mean 30), only one recurrence has been recorded. This tension-free technique allows immediate rehabilitation, with few complications and a low recurrence rate.

  20. The initial experience of introducing the Onstep technique for inguinal hernia repair in a general surgical department

    DEFF Research Database (Denmark)

    Andresen, K; Burcharth, Jakob Hornstrup Frølunde; Rosenberg, J

    2015-01-01

    BACKGROUND AND AIMS: A new technique for the repair of inguinal hernia, called Onstep, has been described. This technique places the mesh in the preperitoneal space medially and between the internal and external oblique muscles laterally. The Onstep technique has not yet been described outside...... repair. Inguinal Pain Questionnaire results: 95.5% reported no pain or pain that was easily ignored. CONCLUSIONS: It seems from this study that the Onstep technique is a safe method for inguinal hernia repair regarding perioperative and postoperative complications. The postoperative pain seems...

  1. Three-Dimensional Coculture of Meniscal Cells and Mesenchymal Stem Cells in Collagen Type I Hydrogel on a Small Intestinal Matrix-A Pilot Study Toward Equine Meniscus Tissue Engineering.

    Science.gov (United States)

    Kremer, Antje; Ribitsch, Iris; Reboredo, Jenny; Dürr, Julia; Egerbacher, Monika; Jenner, Florien; Walles, Heike

    2017-05-01

    Meniscal injuries are the most frequently encountered soft tissue injuries in the equine stifle joint. Due to the inherent limited repair potential of meniscal tissue, meniscal injuries do not only affect the meniscus itself but also lead to impaired joint homeostasis and secondary osteoarthritis. The presented study compares 3D coculture constructs of primary equine mesenchymal stem cells (MSC) and meniscus cells (MC) seeded on three different scaffolds-a cell-laden collagen type I hydrogel (Col I gel), a tissue-derived small intestinal matrix scaffold (SIS-muc) and a combination thereof-for their qualification to be applied for meniscus tissue engineering. To investigate cell attachment of primary MC and MSC on SIS-muc matrix SEM pictures were performed. For molecular analysis, lyophilized samples of coculture constructs with different cell ratios (100% MC, 100% MSC, and 50% MC and 50% MSC, 20% MC, and 80% MSC) were digested and analyzed for DNA and GAG content. Active matrix remodeling of 3D coculture models was indicated by matrix metalloproteinases detection. For comparison of tissue-engineered constructs with the histologic architecture of natural equine menisci, paired lateral and medial menisci of 15 horses representing different age groups were examined. A meniscus phenotype with promising similarity to native meniscus tissue in its GAG/DNA expression in addition to Col I, Col II, and Aggrecan production was achieved using a scaffold composed of Col I gel on SIS-muc combined with a coculture of MC and MSC. The results encourage further development of this scaffold-cell combination for meniscus tissue engineering.

  2. Laparoscopic Pediatric Inguinal Hernia Repair: Overview of "True Herniotomy" Technique and Review of Current Evidence.

    Science.gov (United States)

    Feehan, Brendan P; Fromm, David S

    2017-05-01

    Inguinal hernia repair is one of the most commonly performed operations in the pediatric population. While the majority of pediatric surgeons routinely use laparoscopy in their practices, a relatively small number prefer a laparoscopic inguinal hernia repair over the traditional open repair. This article provides an overview of the three port laparoscopic technique for inguinal hernia repair, as well as a review of the current evidence with respect to visualization and identification of hernias, recurrence rates, operative times, complication rates, postoperative pain, and cosmesis. The laparoscopic repair presents a viable alternative to open repair and offers a number of benefits over the traditional approach. These include superior visualization of the relevant anatomy, ability to assess and repair a contralateral hernia, lower rates of metachronous hernia, shorter operative times in bilateral hernia, and the potential for lower complication rates and improved cosmesis. This is accomplished without increasing recurrence rates or postoperative pain. Further research comparing the different approaches, including standardization of techniques and large randomized controlled trials, will be needed to definitively determine which is superior. Copyright© South Dakota State Medical Association.

  3. Innovative chimney-graft technique for endovascular repair of a pararenal abdominal aortic aneurysm.

    Science.gov (United States)

    Galiñanes, Edgar Luis; Hernandez-Vila, Eduardo A; Krajcer, Zvonimir

    2015-02-01

    After abdominal aortic aneurysm repair, progressive degeneration of the aneurysm can be challenging to treat. Multiple comorbidities and previous operations place such patients at high risk for repeat surgery. Endovascular repair is a possible alternative; however, challenging anatomy can push the limits of available technology. We describe the case of a 71-year-old man who presented with a 5.3-cm pararenal aneurysm 4 years after undergoing open abdominal aortic aneurysm repair. To avoid reoperation, we excluded the aneurysm by endovascular means, using visceral-artery stenting, a chimney-graft technique. Low-profile balloons on a monorail system enabled the rapid exchange of coronary wires via a buddy-wire technique. This novel approach facilitated stenting and simultaneous angioplasty of multiple visceral vessels and the abdominal aorta.

  4. Reliability and Validity of the IKDC, KOOS, and WOMAC for Patients With Meniscal Injuries.

    Science.gov (United States)

    van de Graaf, Victor A; Wolterbeek, Nienke; Scholtes, Vanessa A B; Mutsaerts, Eduard L A R; Poolman, Rudolf W

    2014-06-01

    Several patient-reported outcome measurements are used to measure functional outcome after treatment of meniscal injuries. However, for comparison of study results, there is a need for a uniform and standardized approach of measuring functional outcome. Selection of the instrument should be based on the quality of its measurement properties, and only the best instrument can be justified to be used. This study aimed to determine and compare the measurement properties of the Dutch-language versions of the International Knee Documentation Committee (IKDC) Subjective Knee Form, Knee Injury and Osteoarthritis Outcome Score (KOOS), and Western Ontario and McMaster Universities Arthritis Index (WOMAC) in a homogeneous group of patients with meniscal tears. Cohort study (design); Level of evidence, 2. Patients on the waiting list for meniscal surgery and patients between 6 weeks and 6 months after meniscal surgery were included (n = 75). Patients were excluded if they received an arthroplasty or had surgery on the anterior cruciate ligament. Internal consistency (Cronbach alpha), test-retest reliability (intraclass correlation coefficient [ICC]), measurement error (SEM), smallest detectable difference (SDD), content validity, construct validity (factor analysis and hypothesis testing), and floor and ceiling effects were determined. Results for the IKDC, KOOS dimensions, and WOMAC dimensions, respectively, were as follows: Cronbach alpha = .90, .72-.95, and .84-.95; ICC = 0.93, 0.84-0.89, and 0.77-0.89; SEM = 5.3, 7.0-12.6, and 7.3-12.2; SDD = 14.6, 19.4-35.0, and 20.2-33.9; hypotheses testing confirmation = 100%, 86%, and 85%. Floor effects within the SDD from the minimum score were found for the KOOS Sports/Recreation and Quality of Life dimensions. Ceiling effects within the SDD from the maximum score were found for the KOOS Activities of Daily Living and for all WOMAC dimensions. The IKDC showed the best performance on all measurement properties, implying that the IKDC

  5. Biomechanical Comparison of Arthroscopic Single- and Double-Row Repair Techniques for Acute Bony Bankart Lesions.

    Science.gov (United States)

    Spiegl, Ulrich J; Smith, Sean D; Todd, Jocelyn N; Coatney, Garrett A; Wijdicks, Coen A; Millett, Peter J

    2014-08-01

    Single- and double-row arthroscopic reconstruction techniques for acute bony Bankart lesions have been described in the literature. The double-row fixation technique would provide superior reduction and stability of a simulated bony Bankart lesion at time zero in a cadaveric model compared with the single-row technique. Controlled laboratory study. Testing was performed on 14 matched pairs of glenoids with simulated bony Bankart fractures with a defect width of 25% of the glenoid diameter. Half of the fractures were repaired with a double-row technique, while the contralateral glenoids were repaired with a single-row technique. The quality of fracture reduction was measured with a coordinate measuring machine. To determine the biomechanical stability of the repairs, specimens were preconditioned with 10 sinusoidal cycles between 5 and 25 N at 0.1 Hz and then pulled to failure in the anteromedial direction at a rate of 5 mm/min. Loads at 1 mm and 2 mm of fracture displacement were determined. The double-row technique required significantly higher forces to achieve fracture displacements of 1 mm (mean, 60.6 N; range, 39.0-93.3 N; P = .001) and 2 mm (mean, 94.4 N; range, 43.4-151.2 N; P = .004) than the single-row technique (1 mm: mean, 30.2 N; range, 14.0-54.1 N and 2 mm: mean, 63.7 N; range, 26.6-118.8 N). Significantly reduced fracture displacement was seen after double-row repair for both the unloaded condition (mean, 1.1 mm; range, 0.3-2.4 mm; P = .005) and in response to a 10-N anterior force applied to the defect (mean, 1.6 mm; range, 0.5-2.7 mm; P = .001) compared with single-row repair (unloaded: mean, 2.1 mm; range, 1.3-3.4 mm and loaded: mean, 3.4 mm; range, 1.9-4.7 mm). The double-row fixation technique resulted in improved fracture reduction and superior stability at time zero in this cadaveric model. This information may influence the surgical technique used to treat large osseous Bankart fractures and the postoperative rehabilitation protocols

  6. Patient selection, echocardiographic screening and treatment strategies for interventional tricuspid repair using the edge-to-edge repair technique.

    Science.gov (United States)

    Hausleiter, Jörg; Braun, Daniel; Orban, Mathias; Latib, Azeem; Lurz, Philipp; Boekstegers, Peter; von Bardeleben, Ralph Stephan; Kowalski, Marek; Hahn, Rebecca T; Maisano, Francesco; Hagl, Christian; Massberg, Steffen; Nabauer, Michael

    2018-04-24

    Severe tricuspid regurgitation (TR) has long been neglected despite its well known association with mortality. While surgical mortality rates remain high in isolated tricuspid valve surgery, interventional TR repair is rapidly evolving as an alternative to cardiac surgery in selected patients at high surgical risk. Currently, interventional edge-to-edge repair is the most frequently applied technique for TR repair even though the device has not been developed for this particular indication. Due to the inherent differences in tricuspid and mitral valve anatomy and pathology, percutaneous repair of the tricuspid valve is challenging due to a variety of factors including the complexity and variability of tricuspid valve anatomy, echocardiographic visibility of the valve leaflets, and device steering to the tricuspid valve. Furthermore, it remains to be clarified which patients are suitable for a percutaneous tricuspid repair and which features predict a successful procedure. On the basis of the available experience, we describe criteria for patient selection including morphological valve features, a standardized process for echocardiographic screening, and a strategy for clip placement. These criteria will help to achieve standardization of valve assessment and the procedural approach, and to further develop interventional tricuspid valve repair using either currently available devices or dedicated tricuspid edge-to-edge repair devices in the future. In summary, this manuscript will provide guidance for patient selection and echocardiographic screening when considering edge-to-edge repair for severe TR.

  7. [Plastic repair of tricuspid valve: Carpentier's ring annuloplasty versus De VEGA technique].

    Science.gov (United States)

    Charfeddine, Salma; Hammami, Rania; Triki, Faten; Abid, Leila; Hentati, Mourad; Frikha, Imed; Kammoun, Samir

    2017-01-01

    Tricuspid valve disease has been neglected for a long time by cardiologists and surgeons, but for some years now leakage of tricuspid valve has been demonstrated as a prognostic factor in the evolution of patients with left heart valve disease undergoing surgery. Several techniques for plastic repair of tricuspid valve have been developed and the published studies differ on the results of these techniques; we conducted this study to assess the results of plastic repair of tricuspid valve in a population of patients with a high prevalence of rheumatic disease and to compare Carpentier's ring annuloplasty techniques with DEVEGA plasty. We conducted a retrospective study of patients undergoing plastic repair of tricuspid valve in the Department of Cardiology at the Medicine University of Sfax over a period of 25 years. We compared the results from the Group 1 (Carpentier's ring annuloplasty) with Group 2 (DeVEGA plasty). 91 patients were included in our study, 45 patients in the Group 1 and 46 patients in the Group 2. Most patients had mean or severe TI (83%) before surgery, ring dilation was observed in 90% of patients with no significant difference between the two groups. Immediate results were comparable between the two techniques but during monitoring recurrent, at least mean, insufficiency was significantly more frequent in the DeVEGA plasty Group. The predictive factors for significant recurring long term TI were DeVEGA technique (OR=3.26[1.12-9.28]) in multivariate study and preoperative pulmonary artery systolic pressure (OR=1.06 (1.01-1.12)). Plastic repair of tricuspid valve using Carpentier's ring seems to guarantee better results than DeVEGA plasty. On the other hand, preoperative high PASP is predictive of recurrent leakage of tricuspid valve even after plasty; hence the importance of surgery in the treatment of patients at an early stage of the disease.

  8. Current surgical practices in cleft care: cleft palate repair techniques and postoperative care.

    Science.gov (United States)

    Katzel, Evan B; Basile, Patrick; Koltz, Peter F; Marcus, Jeffrey R; Girotto, John A

    2009-09-01

    The purpose of this study was to objectively report practices commonly used in cleft palate repair in the United States. This study investigates current surgical techniques, postoperative care, and complication rates for cleft palate repair surgery. All 803 surgeon members of the American Cleft Palate-Craniofacial Association were sent online and/or paper surveys inquiring about their management of cleft palate patients. Three-hundred six surveys were received, a 38 percent response rate. This represented responses of surgeons from 100 percent of American Cleft Palate-Craniofacial Association registered cleft teams. Ninety-six percent of respondents perform a one-stage repair. Eighty-five percent of surgeons perform palate surgery when the patient is between 6 and 12 months of age. The most common one-stage repair techniques are the Bardach style (two flaps) with intravelar veloplasty and the Furlow palatoplasty. After surgery, 39 percent of surgeons discharge patients within 24 hours. Another 43 percent discharge patients within 48 hours. During postoperative management, 92 percent of respondents implement feeding restrictions. Eighty-five percent of physicians use arm restraints. Surgeons' self-reported complications rates are minimal: 54 percent report a fistula in less than 5 percent of cases. The reported need for secondary speech surgery varies widely. The majority of respondents repair clefts in one stage. The most frequently used repair techniques are the Furlow palatoplasty and the Bardach style with intravelar veloplasty. After surgery, the majority of surgeons discharge patients in 1 or 2 days, and nearly all surgeons implement feeding restrictions and the use of arm restraints. The varying feeding protocols are reviewed in this article.

  9. What is the best way to fix a polyurethane meniscal scaffold? A biomechanical evaluation of different fixation modes.

    Science.gov (United States)

    Hardeman, Francois; Corten, Kristoff; Mylle, Michiel; Van Herck, Bert; Verdonk, René; Verdonk, Peter; Bellemans, Johan

    2015-01-01

    Ingrowth of meniscal tissue into a meniscal scaffold can be optimized by securely fixing the scaffold into the meniscal remnants. The purpose of this research was to test and compare commonly used suture types and suture materials to fix a meniscal scaffold. Forty fresh porcine menisci were used. All tests used the same polyurethane-based scaffold. The load to failure of horizontal, vertical and diagonal sutures with PDS 0 and with Ethibond 0, and diagonal sutures with Ultra Fast-Fix(®) and Sequent(®) to fix a meniscal scaffold were tested. Five tests were conducted for each configuration. All constructs failed in the scaffold at a mean pullout force of 50.6 N (SD 12.7). Inferior results were noted for vertical sutures (40.1 N, SD 6.3) compared to horizontal (49.8 N, SD 5.5, p = 0.0007) and diagonal (51.7 N, SD 15.6, p = 0.024) sutures and for Ethibond 0 (41.4 N, SD 6.2) compared to PDS 0 (51.3 N, SD 12.9, p = 0.001). When comparing the diagonal suture placements, only Ethibond 0 (42.9 N, SD 5.4) showed significantly inferior results compared to PDS 0 (60.1 N, SD 16.9, p = 0.03), Ultra Fast-Fix(®) (60.1 N, SD 9.3, p = 0.004) and Sequent(®) (65.8 N, SD 4.4, p < 0.0001). The most common failure mode when fixing a polyurethane-based meniscal scaffold is suture pull-through of the scaffold in the distraction mode. This happens at a rather low pullout force and might preclude the use of this scaffold clinically. Vertical sutures and Ethibond 0 multifilament braided sutures fail at lower forces, and the tested commercial devices show promising results.

  10. Occupational kneeling and meniscal tears: a magnetic resonance imaging study in floor layers

    DEFF Research Database (Denmark)

    Rytter, Søren; Jensen, Lilli Kirkeskov; Bonde, Jens Peter

    2009-01-01

    OBJECTIVE: To evaluate the association between occupational kneeling and degenerative meniscal tears. METHODS: Magnetic resonance imaging (MRI) of both knees was conducted in 92 male floor layers and 49 male graphic designers (referents), with a mean age of 55.6 years (range 42-70 yrs). The prese......OBJECTIVE: To evaluate the association between occupational kneeling and degenerative meniscal tears. METHODS: Magnetic resonance imaging (MRI) of both knees was conducted in 92 male floor layers and 49 male graphic designers (referents), with a mean age of 55.6 years (range 42-70 yrs......). The presence of grade 3 MRI signal intensities indicating degenerative tears of the anterior, middle, and posterior one-third of the lateral and medial menisci was assessed on 1.5-Tesla MRI scans. The odds ratio (OR) of meniscal tears was determined among floor layers compared to graphic designers. Using...... logistic regression, models were adjusted for age, body mass index, and knee-straining sports. RESULTS: Degenerative tears were significantly more prevalent in the medial meniscus among floor layers than among graphic designers [OR 2.28, 95% confidence interval (CI) 1.10-4.98] and significantly more floor...

  11. Cell Seeding Densities in Autologous Chondrocyte Implantation Techniques for Cartilage Repair.

    Science.gov (United States)

    Foldager, Casper Bindzus; Gomoll, Andreas H; Lind, Martin; Spector, Myron

    2012-04-01

    Cartilage repair techniques have been among the most intensively investigated treatments in orthopedics for the past decade, and several different treatment modalities are currently available. Despite the extensive research effort within this field, the generation of hyaline cartilage remains a considerable challenge. There are many parameters attendant to each of the cartilage repair techniques that can affect the amount and types of reparative tissue generated in the cartilage defect, and some of the most fundamental of these parameters have yet to be fully investigated. For procedures in which in vitro-cultured autologous chondrocytes are implanted under a periosteal or synthetic membrane cover, or seeded onto a porous membrane or scaffold, little is known about how the number of cells affects the clinical outcome. Few published clinical studies address the cell seeding density that was employed. The principal objective of this review is to provide an overview of the cell seeding densities used in cell-based treatments currently available in the clinic for cartilage repair. Select preclinical studies that have informed the use of specific cell seeding densities in the clinic are also discussed.

  12. Comparison of osmotic swelling influences on meniscal fibrocartilage and articular cartilage tissue mechanics in compression and shear.

    Science.gov (United States)

    Nguyen, An M; Levenston, Marc E

    2012-01-01

    Although the contribution of the circumferential collagen bundles to the anisotropic tensile stiffness of meniscal tissue has been well described, the implications of interactions between tissue components for other mechanical properties have not been as widely examined. This study compared the effects of the proteoglycan-associated osmotic swelling stress on meniscal fibrocartilage and articular cartilage (AC) mechanics by manipulating the osmotic environment and tissue compressive offset. Cylindrical samples were obtained from the menisci and AC of bovine stifles, equilibrated in phosphate-buffered saline solutions ranging from 0.1× to 10×, and tested in oscillatory torsional shear and unconfined compression. Biochemical analysis indicated that treatments and testing did not substantially alter tissue composition. Mechanical testing revealed tissue-specific responses to both increasing compressive offset and decreasing bath salinity. Most notably, reduced salinity dramatically increased the shear modulus of both axially and circumferentially oriented meniscal tissue explants to a much greater extent than for cartilage samples. Combined with previous studies, these findings suggest that meniscal proteoglycans have a distinct structural role, stabilizing, and stiffening the matrix surrounding the primary circumferential collagen bundles. Copyright © 2011 Orthopaedic Research Society.

  13. Performance of PROMIS for Healthy Patients Undergoing Meniscal Surgery.

    Science.gov (United States)

    Hancock, Kyle J; Glass, Natalie; Anthony, Chris A; Hettrich, Carolyn M; Albright, John; Amendola, Annunziato; Wolf, Brian R; Bollier, Matthew

    2017-06-07

    The Patient-Reported Outcomes Measurement Information System (PROMIS) was developed as an extensive question bank with multiple health domains that could be utilized for computerized adaptive testing (CAT). In the present study, we investigated the use of the PROMIS Physical Function CAT (PROMIS PF CAT) in an otherwise healthy population scheduled to undergo surgery for meniscal injury with the hypotheses that (1) the PROMIS PF CAT would correlate strongly with patient-reported outcome instruments that measure physical function and would not correlate strongly with those that measure other health domains, (2) there would be no ceiling effects, and (3) the test burden would be significantly less than that of the traditional measures. Patients scheduled to undergo meniscal surgery completed the PROMIS PF CAT, Knee injury and Osteoarthritis Outcome Score (KOOS), Marx Knee Activity Rating Scale, Short Form-36 (SF-36), and EuroQol-5 Dimension (EQ-5D) questionnaires. Correlations were defined as high (≥0.7), high-moderate (0.61 to 0.69), moderate (0.4 to 0.6), moderate-weak (0.31 to 0.39), or weak (≤0.3). If ≥15% respondents to a patient-reported outcome measure obtained the highest or lowest possible score, the instrument was determined to have a significant ceiling or floor effect. A total of 107 participants were analyzed. The PROMIS PF CAT had a high correlation with the SF-36 Physical Functioning (PF) (r = 0.82, p ceiling effects, with 0% of the participants achieving the lowest and highest score, respectively. The PROMIS PF CAT correlates strongly with currently used patient-reported outcome measures of physical function and demonstrates no ceiling effects for patients with meniscal injury requiring surgery. It may be a reasonable alternative to more burdensome patient-reported outcome measures.

  14. MR imaging of the knee following cruciate ligament reconstruction and meniscal surgery; MRT des Kniegelenks nach Kreuzband- und Meniskusoperationen

    Energy Technology Data Exchange (ETDEWEB)

    Woertler, K. [Technische Univ. Muenchen, Klinikum rechts der Isar (Germany). Inst. fuer Roentgendiagnostik

    2009-03-15

    Due to the increasing number of surgical procedures performed on the knee, MR imaging of the postoperative knee has gained more and more importance. For the evaluation of anterior cruciate ligament grafts and postoperative menisci, basic knowledge of surgical techniques is essential in order to differentiate normal postoperative findings from transplant failure, retears, and complications. This article reviews technical aspects of MR imaging following knee surgery, basic principles of operative techniques for anterior cruciate ligament reconstruction and therapy of meniscal tears, normal postoperative findings, MR imaging criteria for recurrent lesions, and findings with typical complications. (orig.)

  15. The role of meniscal tissue in joint protection in early osteoarthritis.

    Science.gov (United States)

    Verdonk, Rene; Madry, Henning; Shabshin, Nogah; Dirisamer, Florian; Peretti, Giuseppe M; Pujol, Nicolas; Spalding, Tim; Verdonk, Peter; Seil, Romain; Condello, Vincenzo; Di Matteo, Berardo; Zellner, Johannes; Angele, Peter

    2016-06-01

    It is widely accepted that partial meniscectomy leads to early onset of osteoarthritis (OA). A strong correlation exists between the amount and location of the resected meniscus and the development of degenerative changes in the knee. On the other hand, osteoarthritic changes of the joint alter the structural and functional integrity of meniscal tissue. These alterations might additionally compromise the limited healing capacity of the meniscus. In young, active patients without cartilage damage, meniscus therapy including partial meniscectomy, meniscus suture, and meniscus replacement has proven beneficial effects in long-term studies. Even in an early osteoarthritic milieu, there is a relevant regenerative potential of the meniscus and the surrounding cartilage. This potential should be taken into account, and meniscal surgery can be performed with the correct timing and the proper indication even in the presence of early OA.

  16. The PASTA Bridge: A Technique for the Arthroscopic Repair of PASTA Lesions.

    Science.gov (United States)

    Hirahara, Alan M; Andersen, Wyatt J

    2017-10-01

    PASTA (partial articular supraspinatus tendon avulsion) lesions of greater than 50% thickness are usually repaired, whereas those of less than 50% thickness receive subacromial decompression and debridement. However, tears of greater than 25% thickness of the tendon result in increased strain of the adjacent, intact tendon fibers. Re-creating the tendon footprint at the greater tuberosity is the goal of a repair. Transtendon repairs have been considered the gold standard in repair but have shown varying outcomes and are technically difficult procedures. This report details the PASTA bridge-a technique for the arthroscopic, percutaneous repair of PASTA lesions. The PASTA bridge uses a spinal needle to ensure the repair includes the leading edge of the good tissue and is at the appropriate angle and area. Most procedures use a knife or trocar blindly to access the joint to place anchors, which has the potential to damage surrounding tissues and result in poor anchor and suture placement. The PASTA bridge is a safe, reliable procedure that is easily reproducible and appropriate for surgeons of all experience levels and should be strongly considered when repairing PASTA lesions.

  17. Implantation of autogenous meniscal fragments wrapped with a fascia sheath enhances fibrocartilage regeneration in vivo in a large harvest site defect.

    Science.gov (United States)

    Kobayashi, Yasukazu; Yasuda, Kazunori; Kondo, Eiji; Katsura, Taro; Tanabe, Yoshie; Kimura, Masashi; Tohyama, Harukazu

    2010-04-01

    Concerning meniscal tissue regeneration, many investigators have studied the development of a tissue-engineered meniscus. However, the utility still remains unknown. Implantation of autogenous meniscal fragments wrapped with a fascia sheath into the donor site meniscal defect may significantly enhance fibrocartilage regeneration in vivo in the defect. Controlled laboratory study. Seventy-five mature rabbits were used in this study. In each animal, an anterior one-third of the right medial meniscus was resected. Then, the animals were divided into the following 3 groups of 25 rabbits each: In group 1, no treatment was applied to the meniscal defect. In group 2, the defect was covered with a fascia sheath. In group 3, after the resected meniscus was fragmented into small pieces, the fragments were grafted into the defect. Then, the defect with the meniscal fragments was covered with a fascia sheath. In each group, 5 rabbits were used for histological evaluation at 3, 6, and 12 weeks after surgery, and 5 rabbits were used for biomechanical evaluation at 6 and 12 weeks after surgery. Histologically, large round cells in group 3 were scattered in the core portion of the meniscus-shaped tissue, and the matrix around these cells was positively stained by safranin O and toluisin blue at 12 weeks. The histological score of group 3 was significantly higher than that of group 1 and group 2. Biomechanically, the maximal load and stiffness of group 3 were significantly greater than those of groups 1 and 2. This study clearly demonstrated that implantation of autogenous meniscal fragments wrapped with a fascia sheath into the donor site meniscal defect significantly enhanced fibrocartilage regeneration in vivo in the defect at 12 weeks after implantation in the rabbit. This study proposed a novel strategy to treat a large defect after a meniscectomy.

  18. Combined laparoscopic and open technique for repair of congenital abdominal hernia: A case report of prune belly syndrome.

    Science.gov (United States)

    Ye, Qinghuang; Chen, Yan; Zhu, Jinhui; Wang, Yuedong

    2017-10-01

    Prune belly syndrome (PBS) is a rare congenital disorder among adults, and the way for repairing abdominal wall musculature has no unified standard. We described combining laparoscopic and open technique in an adult male who presented with PBS. Physical examination and radiological imaging verified the case of PBS. The deficiency of abdominal wall musculature was repaired by combining laparoscopic and open technique using a double-deck complex patch. The patient successfully underwent abdominal wall repair by combining laparoscopic and open technique. Postoperative recovery was uneventful, and improvement in symptom was significant in follow-up after 3, 6, 12, and 24 months. Combining laparoscopic and open technique for repair of deficiency of abdominal wall musculature in PBS was an exploratory way to improve life quality.

  19. A Cohort Study on Meniscal Lesions among Airport Baggage Handlers

    DEFF Research Database (Denmark)

    Mikkelsen, Sigurd; Brauer, Charlotte; Pedersen, Ellen Bøtker

    2016-01-01

    and then decreased slowly to reach unity after approximately 30 years, adjusted for effects of potential confounders. This relation between baggage handling and meniscal lesions was present for work on the apron which involves lifting in a kneeling or squatting position, but not in the baggage hall, which only...

  20. Anterior cruciate ligament and meniscal injuries in sports: incidence, time of practice until injury, and limitations caused after trauma.

    Science.gov (United States)

    Astur, Diego Costa; Xerez, Marcos; Rozas, João; Debieux, Pedro Vargas; Franciozi, Carlos Eduardo; Cohen, Moises

    2016-01-01

    To analyze the incidence of ACL and meniscal injuries in a population of recreational and elite athletes from Brazil and the relation of these injuries with their sports activities. This was a prospective observational study of 240 patients with ACL and/or meniscal injuries submitted to surgical treatment. Data of patients and sport modality, as well as Tegner score were registered in the first clinical evaluation. The patients were divided into three groups: (1) isolated rupture of the ACL; (2) ACL injury associated with meniscal injury; (3) isolated menisci injury. The majority of the patients belonged to group 1 (44.58%), followed by group 2 (30.2%) and 3 (25%). Most patients were soccer players. The mean time from sport practice to injury in group 1 was 17.81 years. In group 2, it was 17.3 years, and in group 3, 26.91 years. Soccer athletes presented ACL injury in 0.523/1000 h of practice and meniscal injury in 0.448/1000 h of practice. Before the injury, the mean Tegner score obtained for groups 1, 2, and 3 were 7.18, 7.34, and 6.53, respectively. After knee injury, those values were 3.07, 3.18, and 2.87, respectively. Soccer was the sport that caused the majority of lesions, regardless the group. Furthermore, patients from groups 1 and 2 had less time of practice prior to the injury (17.81 and 17.3 years) than the patients of group 3 (26.91 years). Women presented a higher risk to develop ACL and meniscal injuries in 1000 h of game/practice. Running, volleyball, and weightlifting are in ascending order of risk for ACL and/or meniscal injury. Regarding the return to sport practice, the efficiency of all athletes was impaired because of the injury.

  1. Anterior cruciate ligament and meniscal injuries in sports: incidence, time of practice until injury, and limitations caused after trauma

    Directory of Open Access Journals (Sweden)

    Diego Costa Astur

    Full Text Available ABSTRACT OBJECTIVE: To analyze the incidence of ACL and meniscal injuries in a population of recreational and elite athletes from Brazil and the relation of these injuries with their sports activities. METHODS: This was a prospective observational study of 240 patients with ACL and/or meniscal injuries submitted to surgical treatment. Data of patients and sport modality, as well as Tegner score were registered in the first clinical evaluation. The patients were divided into three groups: (1 isolated rupture of the ACL; (2 ACL injury associated with meniscal injury; (3 isolated menisci injury. RESULTS: The majority of the patients belonged to group 1 (44.58%, followed by group 2 (30.2% and 3 (25%. Most patients were soccer players. The mean time from sport practice to injury in group 1 was 17.81 years. In group 2, it was 17.3 years, and in group 3, 26.91 years. Soccer athletes presented ACL injury in 0.523/1000 h of practice and meniscal injury in 0.448/1000 h of practice. Before the injury, the mean Tegner score obtained for groups 1, 2, and 3 were 7.18, 7.34, and 6.53, respectively. After knee injury, those values were 3.07, 3.18, and 2.87, respectively. CONCLUSION: Soccer was the sport that caused the majority of lesions, regardless the group. Furthermore, patients from groups 1 and 2 had less time of practice prior to the injury (17.81 and 17.3 years than the patients of group 3 (26.91 years. Women presented a higher risk to develop ACL and meniscal injuries in 1000 h of game/practice. Running, volleyball, and weightlifting are in ascending order of risk for ACL and/or meniscal injury. Regarding the return to sport practice, the efficiency of all athletes was impaired because of the injury.

  2. Usefulness of meniscal width to transverse diameter ratio on coronal MRI in the diagnosis of incomplete discoid lateral meniscus

    International Nuclear Information System (INIS)

    Park, H.J.; Lee, S.Y.; Park, N.-H.; Chung, E.C.; Park, J.Y.; Kim, M.S.; Lee, E.J.

    2014-01-01

    Aim: To evaluate the clinical utility of the meniscal width to transverse diameter ratio (L/M ratio) of the lateral meniscus in the diagnosis of incomplete discoid lateral meniscus (IDLM) as compared with the arthroscopic diagnosis, meniscal width to tibial diameter ratio (L/T ratio) and conventional lateral meniscus width criteria. Materials and methods: This retrospective study sample included 41 patients with IDLM who underwent knee magnetic resonance imaging (MRI) and arthroscopy, as well as 50 controls with normal lateral menisci. MRI examinations were interpreted independently by two radiologists, both of whom were blinded to clinical information and radiological reports. Assessment of meniscal width (L), maximal transverse diameter of the lateral meniscus (M), and transverse diameter of the tibia (T) was carried out on central coronal sections that were observed to pass through the medial collateral ligament. L/M and L/T ratios were calculated. These results were correlated with arthroscopic findings and analysed statistically using categorical regression analysis and non-parametric correlation analysis. Using arthroscopic findings as the standard of reference, sensitivity and specificity were calculated for: (1) 12, 13, 14, and 15 mm meniscal width thresholds; (2) 40%, 50%, 60%, and 70% L/M ratio thresholds; and (3) 15%, 18%, 20%, and 25% L/T ratio thresholds. Results: The mean L/M ratio of the IDLM was approximately 67% and was statistically significantly higher than the control (44%). The best diagnostic discrimination was achieved using a threshold of 50%. The mean L/T ratio of the IDLM was approximately 23% and was statistically significant. The best diagnostic discrimination was achieved using a threshold of 18%. The threshold of 13 mm of meniscal width also showed high sensitivity and high specificity. Conclusion: The use of the L/M ratio or L/T ratio in combination with meniscal width criteria may be a useful method for evaluating IDLM

  3. Damage Tolerant Repair Techniques for Pressurized Aircraft Fuselages

    Science.gov (United States)

    1994-01-01

    RepoW Techniques for Prwurized Aircraft AXWdOg 4.9 Summary and Conclusions The basics of adhesive bonded repairs for aluminum aircraft fuselages have... of cruise altitude and bending stresses in the plate at the tip of one-sided reinforcements (chapter 5). The expanded Rose model was transformed into a...DEPARTMEN1 OF THE AIR FORCE AGENCY REPORT NUMBER AFIT/CI 2950 P STREET WRIGHT-PATTERSON AFB OH 45433-7765 11. SUPPLEMENTARY NOTES Usa. DISTRUISUIOII

  4. Identification, Characterization, and Utilization of Adult Meniscal Progenitor Cells

    Science.gov (United States)

    2017-11-01

    meniscal findings on knee MRI in middle-aged and elderly persons. N. Engl. J. Med. 359, 1108–1115.802 Stem Cell Reports j Vol. 3 j 789–803 j November 11...PBS, pH¼7.4) with protease inhibitors (Pierce Protease Inhibitor Tablets 88266, Thermo Fisher Scientific, Rockford, IL) at 4 1C for less than 24 h

  5. Changes in rates of arthroscopy due to degenerative knee disease and traumatic meniscal tears in Finland and Sweden.

    Science.gov (United States)

    Mattila, Ville M; Sihvonen, Raine; Paloneva, Juha; Felländer-Tsai, Li

    2016-02-01

    Knee arthroscopy is commonly performed to treat degenerative knee disease symptoms and traumatic meniscal tears. We evaluated whether the recent high-quality randomized control trials not favoring arthroscopic surgery for degenerative knee disease affected the procedure incidence and trends in Finland and Sweden. We conducted a bi-national registry-based study including all adult (aged ≥18 years) inpatient and outpatient arthroscopic surgeries performed for degenerative knee disease (osteoarthritis (OA) and degenerative meniscal tears) and traumatic meniscal tears in Finland between 1997 and 2012, and in Sweden between 2001 and 2012. In Finland, the annual number of operations was 16,389 in 1997, reached 20,432 in 2007, and declined to 15,018 in 2012. In Sweden, the number of operations was 9,944 in 2001, reached 11,711 in 2008, and declined to 8,114 in 2012. The knee arthroscopy incidence for OA was 124 per 10(5) person-years in 2012 in Finland and it was 51 in Sweden. The incidence of knee arthroscopies for meniscal tears coded as traumatic steadily increased in Finland from 64 per 10(5) person-years in 1997 to 97 per 10(5) person-years in 2012, but not in Sweden. The incidence of arthroscopies for degenerative knee disease declined after 2008 in both countries. Remarkably, the incidence of arthroscopy for degenerative knee disease and traumatic meniscal tears is 2 to 4 times higher in Finland than in Sweden. Efficient implementation of new high-quality evidence in clinical practice could reduce the number of ineffective surgeries.

  6. Changes in rates of arthroscopy due to degenerative knee disease and traumatic meniscal tears in Finland and Sweden

    Science.gov (United States)

    Mattila, Ville M; Sihvonen, Raine; Paloneva, Juha; Felländer-Tsai, Li

    2016-01-01

    Background and purpose Knee arthroscopy is commonly performed to treat degenerative knee disease symptoms and traumatic meniscal tears. We evaluated whether the recent high-quality randomized control trials not favoring arthroscopic surgery for degenerative knee disease affected the procedure incidence and trends in Finland and Sweden. Patients and methods We conducted a bi-national registry-based study including all adult (aged ≥18 years) inpatient and outpatient arthroscopic surgeries performed for degenerative knee disease (osteoarthritis (OA) and degenerative meniscal tears) and traumatic meniscal tears in Finland between 1997 and 2012, and in Sweden between 2001 and 2012. Results In Finland, the annual number of operations was 16,389 in 1997, reached 20,432 in 2007, and declined to 15,018 in 2012. In Sweden, the number of operations was 9,944 in 2001, reached 11,711 in 2008, and declined to 8,114 in 2012. The knee arthroscopy incidence for OA was 124 per 105 person-years in 2012 in Finland and it was 51 in Sweden. The incidence of knee arthroscopies for meniscal tears coded as traumatic steadily increased in Finland from 64 per 105 person-years in 1997 to 97 per 105 person-years in 2012, but not in Sweden. Interpretation The incidence of arthroscopies for degenerative knee disease declined after 2008 in both countries. Remarkably, the incidence of arthroscopy for degenerative knee disease and traumatic meniscal tears is 2 to 4 times higher in Finland than in Sweden. Efficient implementation of new high-quality evidence in clinical practice could reduce the number of ineffective surgeries. PMID:26122621

  7. Value of Fat-Suppressed Proton-Density-Weighted Turbo Spin-Echo Sequences in Detecting Meniscal Lesions: Comparison with Arthroscopy

    International Nuclear Information System (INIS)

    Schaefer, F.K.W.; Schaefer, P.J.; Brossmann, J.; Frahm, C.; Hilgert, R.E.; Heller, M.; Jahnke, T.

    2006-01-01

    Purpose: To evaluate fat-suppressed (FS) proton-density-weighted (PDw) turbo spin-echo (TSE) magnetic resonance imaging (MRI) compared to arthroscopy in the detection of meniscal lesions. Material and Methods: In a prospective study, 31 knee joints were imaged on a 1.5T MR scanner before arthroscopy using the following sequences: (a) coronal and sagittal FS-PDw TSE (TR/TE: 4009/15 ms); (b) coronal T1w SE (TR/TE: 722/20 ms), and sagittal PDw TSE (TR/TE: 3800/15 ms). Other imaging parameters were: slice thickness 3 mm, FOV 160 mm, matrix 256x256. A total of 186 meniscal regions (62 menisci; anterior horn, body, posterior horn) were evaluated. Standard of reference was arthroscopy. Sensitivity, specificity, negative predictive value (npv), positive predictive value (ppv), and accuracy were calculated. Results: Arthroscopically, meniscal lesions were detected in 55/186 segments (35 medial and 20 lateral meniscal lesions). Sensitivity, specificity, npv, ppv, and accuracy for combination of coronal and sagittal FS PDw TSE were 91.4%, 98.3%, 95%, 97%, and 93.5% for the medial meniscus, and 90%, 98.6%, 97.3%, 94.7%, and 96.8% for the lateral. The results were comparable to the combination of coronal T1w SE and sagittal PDw TSE for the medial (88.6%, 98.3%, 93.4%, 96.9%, 91.4%) and the lateral (90%, 95.9%, 97.2%, 85.7%, 92.5%) meniscus. Conclusion: FS PDw TSE-MR sequences are an excellent alternative for the detection of meniscal lesions in comparison with diagnostic arthroscopy

  8. Endovascular Aortic Aneurysm Repair with Chimney and Snorkel Grafts: Indications, Techniques and Results

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Rakesh P., E-mail: rpatel9@nhs.net [Northwick Park Hospital, Department of Vascular Radiology (United Kingdom); Katsargyris, Athanasios, E-mail: kthanassos@yahoo.com; Verhoeven, Eric L. G., E-mail: Eric.Verhoeven@klinikum-nuernberg.de [Klinikum Nuernberg, Department of Vascular and Endovascular Surgery (Germany); Adam, Donald J., E-mail: donald.adam@tiscali.co.uk [Heartlands Hospital, Department of Vascular Surgery (United Kingdom); Hardman, John A., E-mail: johnhardman@doctors.org.uk [Royal United Hospital Bath, Department of Vascular Radiology (United Kingdom)

    2013-12-15

    The chimney technique in endovascular aortic aneurysm repair (Ch-EVAR) involves placement of a stent or stent-graft parallel to the main aortic stent-graft to extend the proximal or distal sealing zone while maintaining side branch patency. Ch-EVAR can facilitate endovascular repair of juxtarenal and aortic arch pathology using available standard aortic stent-grafts, therefore, eliminating the manufacturing delays required for customised fenestrated and branched stent-grafts. Several case series have demonstrated the feasibility of Ch-EVAR both in acute and elective cases with good early results. This review discusses indications, technique, and the current available clinical data on Ch-EVAR.

  9. All-inside arthroscopic lateral collateral ligament repair for ankle instability with a knotless suture anchor technique.

    Science.gov (United States)

    Vega, Jordi; Golanó, Pau; Pellegrino, Alexandro; Rabat, Eduard; Peña, Fernando

    2013-12-01

    Recently, arthroscopic-assisted techniques have been described to treat lateral ankle instability with excellent results. However, complications including neuritis of the superficial peroneal or sural nerve, and pain or discomfort due to a prominent anchor or suture knot have been reported. The aim of this study was to describe a novel technique, the "all-inside arthroscopic lateral collateral ankle ligament repair," and its results for treating patients with ankle instability. Sixteen patients (10 men and 6 women, mean age 29.3 years, 17-46) with lateral ankle instability were treated with an arthroscopic procedure. Using a suture passer and a knotless anchor, the ligaments were repaired with an all-inside technique. The right ankle was affected in 10 cases. Mean follow-up was 22.3 (12-35) months. On arthroscopic examination, 13 patients had an isolated anterior talofibular ligament (ATFL) injury, and in 3 patients, both the ATFL and calcaneofibular ligament (CFL) were affected. All-inside arthroscopic anatomic repair of the lateral collateral ligament complex was performed in all cases. All patients reported subjective improvement of their ankle instability. The mean AOFAS score increased from 67 preoperatively to 97 at final follow-up. No major complications were reported. The all-inside arthroscopic ligament repair was a safe, reliable, and reproducible technique that both provided an anatomic repair of the lateral collateral ligament complex and restored ankle stability while preserving all the advantages of an arthroscopic technique. Level IV, retrospective case series.

  10. Recurrent Tricuspid Insufficiency: Is the Surgical Repair Technique a Risk Factor?

    OpenAIRE

    Kara, Ibrahim; Koksal, Cengiz; Cakalagaoglu, Canturk; Sahin, Muslum; Yanartas, Mehmet; Ay, Yasin; Demir, Serdar

    2013-01-01

    This study compares the medium-term results of De Vega, modified De Vega, and ring annuloplasty techniques for the correction of tricuspid insufficiency and investigates the risk factors for recurrent grades 3 and 4 tricuspid insufficiency after repair.

  11. Capstan screw rotator cuff repair: a novel two-row mini-open technique

    Science.gov (United States)

    Goubran, Alex; Jaques, Aishling; Smith, Christopher; Bunker, Tim

    2014-01-01

    Background Prospective data collection occurred between 2000 and 2010 on 143 consecutive patients with symptomatic rotator cuff tears, aiming to examine the end-result of a new technique of mini-open double row repair: the Capstan screw technique. Methods All patients had a pre- and postoperative Oxford Shoulder Score (OSS), American Shoulder and Elbow Surgeons (ASES) score and range of movement measurements. All were followed up for a minimum of 1 year with an exit questionnaire. Subscapularis repairs, small (5 cm) supraspinatus repairs were excluded. Ninety-nine patients fitted the inclusion and exclusion criteria of whom 87 had a complete data set. Results The mean (SD) pre-operative OSS was 21.85 (8.6) and the mean (SD) postoperative OSS was 44.58 (5.2) (p < 0.0001). The mean (SD) pre-operative ASES score was 51.5 (19.4) and the mean (SD) postoperative ASES score was 86.42 (17.06) (p < 0.0001). Flexion improved from a mean of 119° to 170° (p < 0.0001). The clinical re-tear rate was 3.4% and the imaged re-tear rate was 6.8%. In total, 91% of patients were satisfied with the procedure. There were no deep infections and two (2%) minor wound infections. There was no single instance of deltoid dysfunction. Conclusions The Capstan screw technique represents a simple, rapid, strong and reliable mini-open technique. PMID:27582933

  12. Simultaneous demonstration of UV-type and ionizing radiation-type DNA repair by the nucleoid sedimentation technique

    International Nuclear Information System (INIS)

    Aldenhoff, P.; Sperling, K.

    1984-01-01

    The nucleoid sedimentation technique is one of the most sensitive methods for measuring DNA excision repair. With this technique, it is shown that both UV- and ionizing radiation-type repair (the latter induced by bleomycin) can be discriminated in HeLa and normal diploid cells using 1-β-D-arabinofuranosylcytosine. The latter compound inhibits UV-type repair synthesis, and thus causes DNA breaks due to enzymic incision to persist, but has no effect on rejoining DNA after ionizing radiation-type damage. It was then possible to prove that 4-nitroquinoline-1-oxide induces both types of lesions which are repaired simultaneously. This effect could be demonstrated in HeLa and normal human diploid cells in a single experimental set-up. (Auth.)

  13. Minilaparoscopic technique for inguinal hernia repair combining transabdominal pre-peritoneal and totally extraperitoneal approaches.

    Science.gov (United States)

    Carvalho, Gustavo L; Loureiro, Marcelo P; Bonin, Eduardo A; Claus, Christiano P; Silva, Frederico W; Cury, Antonio M; Fernandes, Flavio A M

    2012-01-01

    Endoscopic surgical repair of inguinal hernia is currently conducted using 2 techniques: the totally extraperitoneal (TEP) and the transabdominal (TAPP) hernia repair. The TEP procedure is technically advantageous, because of the use of no mesh fixation and the elimination of the peritoneal flap, leading to less postoperative pain and faster recovery. The drawback is that TEP is not performed as frequently, because of its complexity and longer learning curve. In this study, we propose a hybrid technique that could potentially become the gold standard of minimally invasive inguinal hernia surgery. This will be achieved by combining established advantages of TEP and TAPP associated with the precision and cosmetics of minilaparoscopy (MINI). Between January and July 2011, 22 patients were admitted for endoscopic inguinal hernia repair. The combined technique was initiated with TAPP inspection and direct visualization of a minilaparoscopic trocar dissection of the preperitoneum space. A10-mm trocar was then placed inside the previously dissected preperitoneal space, using the same umbilical TAPP skin incision. Minilaparoscopic retroperitoneal dissection was completed by TEP, and the surgical procedure was finalized with intraperitoneal review and correction of the preperitoneal work. The minilaparoscopic TEP-TAPP combined approach for inguinal hernia is feasible, safe, and allows a simple endoscopic repair. This is achieved by combining features and advantages of both TAPP and TEP techniques using precise and sophisticated MINI instruments. Minilaparoscopic preperitoneal dissection allows a faster and easier creation of the preperitoneal space for the TEP component of the procedure.

  14. Evaluation of a New Knotless Suture Anchor Repair in Acute Achilles Tendon Ruptures: A Biomechanical Comparison of Three Techniques.

    Science.gov (United States)

    Cottom, James M; Baker, Joseph S; Richardson, Phillip E; Maker, Jared M

    Acute ruptures of the Achilles tendon are a common injury, and debate has continued in published studies on how best to treat these injuries. Specifically, controversy exists regarding the surgical approaches for Achilles tendon repair when one considers percutaneous versus open repair. The present study investigated the biomechanical strength of 3 different techniques for Achilles tendon repair in a cadaveric model. A total of 36 specimens were divided into 3 groups, each of which received a different construct. The first group received a traditional Krackow suture repair, the second group was repaired using a jig-assisted percutaneous suture, and the third group received a repair using a jig-assisted percutaneous repair modified with suture anchors placed into the calcaneus. The specimens were tested with cyclical loading and to ultimate failure. Cyclical loading showed a trend toward a stronger repair with the use of suture anchors after 10 cycles (p = .295), 500 cycles (p = .120), and 1000 cycles (p = .040). The ultimate load to failure was greatest in the group repaired with the modified knotless technique using the suture anchors (p = .098). The results of the present study show a clear trend toward a stronger construct in Achilles repair using a knotless suture anchor technique, which might translate to a faster return to activity and be more resistant to an early and aggressive rehabilitation protocol. Further clinical studies are warranted to evaluate this technique in a patient population. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Sportsmen's Groin-Diagnostic Approach and Treatment With the Minimal Repair Technique: A Single-Center Uncontrolled Clinical Review.

    Science.gov (United States)

    Muschaweck, Ulrike; Berger, Luise Masami

    2010-05-01

    Sportsmen's groin, also called sports hernia and Gilmore groin, is one of the most frequent sports injuries in athletes and may place an athletic career at risk. It presents with acute or chronic groin pain exacerbated with physical activity. So far, there is little consensus regarding pathogenesis, diagnostic criteria, or treatment. There have been various attempts to explain the cause of the groin pain. The assumption is that a circumscribed weakness in the posterior wall of the inguinal canal, which leads to a localized bulge, induces a compression of the genital branch of the genitofemoral nerve, considered responsible for the symptoms. The authors developed an innovative open suture repair-the Minimal Repair technique-to fit the needs of professional athletes. With this technique, the circumscribed weakness of the posterior wall of the inguinal canal is repaired by an elastic suture; the compression on the nerve is abolished, and the cause of the pain is removed. In contrast with that of common open suture repairs, the defect of the posterior wall is not enlarged, the suture is nearly tension free, and the patient can return to full training and athletic activity within a shorter time. The outcome of patients undergoing operations with the Minimal Repair technique was compared with that of commonly used surgical procedures. THE FOLLOWING ADVANTAGES OF THE MINIMAL REPAIR TECHNIQUE WERE FOUND: no insertion of prosthetic mesh, no general anesthesia required, less traumatization, and lower risk of severe complications with equal or even faster convalescence. In 2009, a prospective cohort of 129 patients resumed training in 7 days and experienced complete pain relief in an average of 14 days. Professional athletes (67%) returned to full activity in 14 days (median). The Minimal Repair technique is an effective and safe way to treat sportsmen's groin.

  16. Umbilical cord sparing technique for repair of congenital hernia into the cord and small omphalocele.

    Science.gov (United States)

    Ceccanti, Silvia; Falconi, Ilaria; Frediani, Simone; Boscarelli, Alessandro; Musleh, Layla; Cozzi, Denis A

    2017-01-01

    Current repair of small omphaloceles and hernias into the umbilical cord is a straightforward procedure, whose repair may result in a suboptimal cosmetic outcome. We describe a novel repair technique retaining the umbilical cord elements in an attempt to improve the cosmetic appearance of the umbilicus. Eight neonates were consecutively treated more than a ten-year period. Size of the fascial defects ranged 1 to 3cm (median, 2). Present technique entails incision of the amniotic sac without its detachment from the skin, reduction of the extruded contents under direct vision, and closure of the abdominal wall defect by circumferential suturing of peritoneum and fascia around the base of the amniotic sac. The amniotic sac is then re-approximated and folded to create an umbilical stump, which is trimmed and left to shed naturally. All patients achieved a scarless abdomen with a normal appearing umbilicus in 6. The remaining 2 patients are awaiting surgery for persisting umbilical hernia repair and umbilicoplasty, respectively. Poor esthetic outcome was significantly associated with initial fascial defect ≥2.5cm in size (p=0.03). Present technique is a simple and cosmetically appealing repair for umbilical cord hernias and small omphaloceles, especially effective when the size of the fascial defect is less than 2.5cm. IV (Treatment Study). Copyright © 2017 Elsevier Inc. All rights reserved.

  17. An Enhanced Vacuum Cure Technique for On-Aircraft Repair of Carbon-Bismaleimide Composites

    Science.gov (United States)

    Rider, Andrew N.; Baker, Alan A.; Wang, Chun H.; Smith, Graeme

    2011-06-01

    Carbon/bismaleimide (BMI) composite is increasingly employed in critical load carrying aircraft structures designed to operate at temperatures approaching 180°C. The high post-cure temperature (above 220°C) required to fully react the BMI resin, however, renders existing on-aircraft prepreg or wet layup repair methods invalid. This paper presents a new on-aircraft repair technique for carbon/BMI composites. The composite prepregs are first warm-staged to improve the ability to evacuate entrapped air. Then the patch is cured in the scarf cavity using the vacuum bag technique, followed by off-aircraft post-cure. The fully cured patch then can be bonded using a structural adhesive.

  18. Patient-reported outcome measures for patients with meniscal tears: a systematic review of measurement properties and evaluation with the COSMIN checklist

    Science.gov (United States)

    Middleton, Robert; Beard, David J; Price, Andrew J; Hopewell, Sally

    2017-01-01

    Objective Meniscal tears occur frequently in the population and the most common surgical treatment, arthroscopic partial meniscectomy, is performed in approximately two million cases worldwide each year. The purpose of this systematic review is to summarise and critically appraise the evidence for the use of patient-reported outcome measures (PROMs) in patients with meniscal tears. Design A systematic review was undertaken. Data on reported measurement properties were extracted and the quality of the studies appraised according to Consensus-based Standards for the Selection of Health Measurement Instruments. Data sources A search of MEDLINE, Embase, AMED and PsycINFO, unlimited by language or publication date (last search 20 February 2017). Eligibility criteria for selecting studies Development and validation studies reporting the measurement properties of PROMs in patients with meniscal tears were included. Results 11 studies and 10 PROMs were included. The overall quality of studies was poor. For measurement of symptoms and functional status, there is only very limited evidence supporting the selection of either the Lysholm Knee Scale, International Knee Documentation Committee Subjective Knee Form or the Dutch version of the Knee injury and Osteoarthritis Outcome Score. For measuring health-related quality of life, only limited evidence supports the selection of the Western Ontario Meniscal Evaluation Tool (WOMET). Of all the PROMs evaluated, WOMET has the strongest evidence for content validity. Conclusion For patients with meniscal tears, there is poor quality and incomplete evidence regarding the validity of the currently available PROMs. Further research is required to ensure these PROMs truly reflect the symptoms, function and quality of life of patients with meniscal tears. PROSPERO registration number CRD42017056847. PMID:29030413

  19. A Novel Analytic Technique for the Service Station Reliability in a Discrete-Time Repairable Queue

    Directory of Open Access Journals (Sweden)

    Renbin Liu

    2013-01-01

    Full Text Available This paper presents a decomposition technique for the service station reliability in a discrete-time repairable GeomX/G/1 queueing system, in which the server takes exhaustive service and multiple adaptive delayed vacation discipline. Using such a novel analytic technique, some important reliability indices and reliability relation equations of the service station are derived. Furthermore, the structures of the service station indices are also found. Finally, special cases and numerical examples validate the derived results and show that our analytic technique is applicable to reliability analysis of some complex discrete-time repairable bulk arrival queueing systems.

  20. Effect of shoulder abduction angle on biomechanical properties of the repaired rotator cuff tendons with 3 types of double-row technique.

    Science.gov (United States)

    Mihata, Teruhisa; Fukuhara, Tetsutaro; Jun, Bong Jae; Watanabe, Chisato; Kinoshita, Mitsuo

    2011-03-01

    After rotator cuff repair, the shoulder is immobilized in various abduction positions. However, there is no consensus on the proper abduction angle. To assess the effect of shoulder abduction angle on the biomechanical properties of the repaired rotator cuff tendons among 3 types of double-row techniques. Controlled laboratory study. Thirty-two fresh-frozen porcine shoulders were used. A simulated rotator cuff tear was repaired by 1 of 3 double-row techniques: conventional double-row repair, transosseous-equivalent repair, and a combination of conventional double-row and bridging sutures (compression double-row repair). Each specimen underwent cyclic testing followed by tensile testing to failure at a simulated shoulder abduction angle of 0° or 40° on a material testing machine. Gap formation and failure loads were measured. Gap formation in conventional double-row repair at 0° (1.2 ± 0.5 mm) was significantly greater than that at 40° (0.5 ± 0.3mm, P = .01). The yield and ultimate failure loads for conventional double-row repair at 40° were significantly larger than those at 0° (P row repair (P row repair was the greatest among the 3 double-row techniques at both 0° and 40° of abduction. Bridging sutures have a greater effect on the biomechanical properties of the repaired rotator cuff tendon at a low abduction angle, and the conventional double-row technique has a greater effect at a high abduction angle. Proper abduction position after rotator cuff repair differs between conventional double-row repair and transosseous-equivalent repair. The authors recommend the use of the combined technique of conventional double-row and bridging sutures to obtain better biomechanical properties at both low and high abduction angles.

  1. Advances in combining gene therapy with cell and tissue engineering-based approaches to enhance healing of the meniscus.

    Science.gov (United States)

    Cucchiarini, M; McNulty, A L; Mauck, R L; Setton, L A; Guilak, F; Madry, H

    2016-08-01

    Meniscal lesions are common problems in orthopaedic surgery and sports medicine, and injury or loss of the meniscus accelerates the onset of knee osteoarthritis (OA). Despite a variety of therapeutic options in the clinics, there is a critical need for improved treatments to enhance meniscal repair. In this regard, combining gene-, cell-, and tissue engineering-based approaches is an attractive strategy to generate novel, effective therapies to treat meniscal lesions. In the present work, we provide an overview of the tools currently available to improve meniscal repair and discuss the progress and remaining challenges for potential future translation in patients. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  2. Cartilage Repair Surgery: Outcome Evaluation by Using Noninvasive Cartilage Biomarkers Based on Quantitative MRI Techniques?

    Science.gov (United States)

    Jungmann, Pia M.; Baum, Thomas; Bauer, Jan S.; Karampinos, Dimitrios C.; Link, Thomas M.; Li, Xiaojuan; Trattnig, Siegfried; Rummeny, Ernst J.; Woertler, Klaus; Welsch, Goetz H.

    2014-01-01

    Background. New quantitative magnetic resonance imaging (MRI) techniques are increasingly applied as outcome measures after cartilage repair. Objective. To review the current literature on the use of quantitative MRI biomarkers for evaluation of cartilage repair at the knee and ankle. Methods. Using PubMed literature research, studies on biochemical, quantitative MR imaging of cartilage repair were identified and reviewed. Results. Quantitative MR biomarkers detect early degeneration of articular cartilage, mainly represented by an increasing water content, collagen disruption, and proteoglycan loss. Recently, feasibility of biochemical MR imaging of cartilage repair tissue and surrounding cartilage was demonstrated. Ultrastructural properties of the tissue after different repair procedures resulted in differences in imaging characteristics. T2 mapping, T1rho mapping, delayed gadolinium-enhanced MRI of cartilage (dGEMRIC), and diffusion weighted imaging (DWI) are applicable on most clinical 1.5 T and 3 T MR scanners. Currently, a standard of reference is difficult to define and knowledge is limited concerning correlation of clinical and MR findings. The lack of histological correlations complicates the identification of the exact tissue composition. Conclusions. A multimodal approach combining several quantitative MRI techniques in addition to morphological and clinical evaluation might be promising. Further investigations are required to demonstrate the potential for outcome evaluation after cartilage repair. PMID:24877139

  3. Cartilage Repair Surgery: Outcome Evaluation by Using Noninvasive Cartilage Biomarkers Based on Quantitative MRI Techniques?

    Directory of Open Access Journals (Sweden)

    Pia M. Jungmann

    2014-01-01

    Full Text Available Background. New quantitative magnetic resonance imaging (MRI techniques are increasingly applied as outcome measures after cartilage repair. Objective. To review the current literature on the use of quantitative MRI biomarkers for evaluation of cartilage repair at the knee and ankle. Methods. Using PubMed literature research, studies on biochemical, quantitative MR imaging of cartilage repair were identified and reviewed. Results. Quantitative MR biomarkers detect early degeneration of articular cartilage, mainly represented by an increasing water content, collagen disruption, and proteoglycan loss. Recently, feasibility of biochemical MR imaging of cartilage repair tissue and surrounding cartilage was demonstrated. Ultrastructural properties of the tissue after different repair procedures resulted in differences in imaging characteristics. T2 mapping, T1rho mapping, delayed gadolinium-enhanced MRI of cartilage (dGEMRIC, and diffusion weighted imaging (DWI are applicable on most clinical 1.5 T and 3 T MR scanners. Currently, a standard of reference is difficult to define and knowledge is limited concerning correlation of clinical and MR findings. The lack of histological correlations complicates the identification of the exact tissue composition. Conclusions. A multimodal approach combining several quantitative MRI techniques in addition to morphological and clinical evaluation might be promising. Further investigations are required to demonstrate the potential for outcome evaluation after cartilage repair.

  4. Development and validation of predictive simulation model of multi-layer repair welding process by temper bead technique

    International Nuclear Information System (INIS)

    Okano, Shigetaka; Miyasaka, Fumikazu; Mochizuki, Masahito; Tanaka, Manabu

    2015-01-01

    Stress corrosion cracking (SCC) has recently been observed in the nickel base alloy weld metal of dissimilar pipe joint used in pressurized water reactor (PWR) . Temper bead technique has been developed as one of repair procedures against SCC applicable in case that post weld heat treatment (PWHT) is difficult to carry out. In this regard, however it is essential to pass the property and performance qualification test to confirm the effect of tempering on the mechanical properties at repair welds before temper bead technique is actually used in practice. Thus the appropriate welding procedure conditions in temper bead technique are determined on the basis of the property and performance qualification testing. It is necessary for certifying the structural soundness and reliability at repair welds but takes a lot of work and time in the present circumstances. Therefore it is desirable to establish the reasonable alternatives for qualifying the property and performance at repair welds. In this study, mathematical modeling and numerical simulation procedures were developed for predicting weld bead configuration and temperature distribution during multi-layer repair welding process by temper bead technique. In the developed simulation technique, characteristics of heat source in temper bead welding are calculated from weld heat input conditions through the arc plasma simulation and then weld bead configuration and temperature distribution during temper bead welding are calculated from characteristics of heat source obtained through the coupling analysis between bead surface shape and thermal conduction. The simulation results were compared with the experimental results under the same welding heat input conditions. As the results, the bead surface shape and temperature distribution, such as A cl lines, were in good agreement between simulation and experimental results. It was concluded that the developed simulation technique has the potential to become useful for

  5. Determining flexor-tendon repair techniques via soft computing

    Science.gov (United States)

    Johnson, M.; Firoozbakhsh, K.; Moniem, M.; Jamshidi, M.

    2001-01-01

    An SC-based multi-objective decision-making method for determining the optimal flexor-tendon repair technique from experimental and clinical survey data, and with variable circumstances, was presented. Results were compared with those from the Taguchi method. Using the Taguchi method results in the need to perform ad-hoc decisions when the outcomes for individual objectives are contradictory to a particular preference or circumstance, whereas the SC-based multi-objective technique provides a rigorous straightforward computational process in which changing preferences and importance of differing objectives are easily accommodated. Also, adding more objectives is straightforward and easily accomplished. The use of fuzzy-set representations of information categories provides insight into their performance throughout the range of their universe of discourse. The ability of the technique to provide a "best" medical decision given a particular physician, hospital, patient, situation, and other criteria was also demonstrated.

  6. International Meniscus Reconstruction Experts Forum (IMREF) 2015 Consensus Statement on the Practice of Meniscal Allograft Transplantation.

    Science.gov (United States)

    Getgood, Alan; LaPrade, Robert F; Verdonk, Peter; Gersoff, Wayne; Cole, Brian; Spalding, Tim

    2016-08-25

    Meniscal allograft transplantation (MAT) has become relatively commonplace in specialized sport medicine practice for the treatment of patients with a symptomatic knee after the loss of a functional meniscus. The technique has evolved since the 1980s, and long-term results continue to improve. However, there still remains significant variation in how MAT is performed, and as such, there remains opportunity for outcome and graft survivorship to be optimized. The purpose of this article was to develop a consensus statement on the practice of MAT from key opinion leaders who are members of the International Meniscus Reconstruction Experts Forum so that a more standardized approach to the indications, surgical technique, and postoperative care could be outlined with the goal of ultimately improving patient outcomes. © 2016 The Author(s).

  7. Evaluation of Meniscal Mechanics and Proteoglycan Content in a Modified Anterior Cruciate Ligament Transection Model

    Science.gov (United States)

    Fischenich, Kristine M.; Coatney, Garrett A.; Haverkamp, John H.; Button, Keith D.; DeCamp, Charlie; Haut, Roger C.; Haut Donahue, Tammy L.

    2014-01-01

    Post-traumatic osteoarthritis (PTOA) develops as a result of traumatic loading that causes tears of the soft tissues in the knee. A modified transection model, where the anterior cruciate ligament (ACL) and both menisci were transected, was used on skeletally mature Flemish Giant rabbits. Gross morphological assessments, elastic moduli, and glycosaminoglycan (GAG) coverage of the menisci were determined to quantify the amount of tissue damage 12 weeks post injury. This study is one of the first to monitor meniscal changes after inducing combined meniscal and ACL transections. A decrease in elastic moduli as well as a decrease in GAG coverage was seen. PMID:24749144

  8. Influence of Rotator Cuff Tear Size and Repair Technique on the Creation and Management of Dog Ear Deformities in a Transosseous-Equivalent Rotator Cuff Repair Model

    Science.gov (United States)

    Redler, Lauren H.; Byram, Ian R.; Luchetti, Timothy J.; Tsui, Ying Lai; Moen, Todd C.; Gardner, Thomas R.; Ahmad, Christopher S.

    2014-01-01

    Background: Redundancies in the rotator cuff tissue, commonly referred to as “dog ear” deformities, are frequently encountered during rotator cuff repair. Knowledge of how these deformities are created and their impact on rotator cuff footprint restoration is limited. Purpose: The goals of this study were to assess the impact of tear size and repair method on the creation and management of dog ear deformities in a human cadaveric model. Study Design: Controlled laboratory study. Methods: Crescent-shaped tears were systematically created in the supraspinatus tendon of 7 cadaveric shoulders with increasing medial to lateral widths (0.5, 1.0, and 1.5 cm). Repair of the 1.5-cm tear was performed on each shoulder with 3 methods in a randomized order: suture bridge, double-row repair with 2-mm fiber tape, and fiber tape with peripheral No. 2 nonabsorbable looped sutures. Resulting dog ear deformities were injected with an acrylic resin mixture, digitized 3-dimensionally (3D), and photographed perpendicular to the footprint with calibration. The volume, height, and width of the rotator cuff tissue not in contact with the greater tuberosity footprint were calculated using the volume injected, 3D reconstructions, and calibrated photographs. Comparisons were made between tear size, dog ear measurement technique, and repair method utilizing 2-way analysis of variance and Student-Newman-Keuls multiple-comparison tests. Results: Utilizing 3D digitized and injection-derived volumes and dimensions, anterior dog ear volume, height, and width were significantly smaller for rotator cuff repair with peripheral looped sutures compared with a suture bridge (P repair with 2-mm fiber tape alone (P repair with looped peripheral sutures compared with a suture bridge (P repair technique, peripheral No. 2 nonabsorbable looped sutures significantly decreased the volume, height, and width of dog ear deformities, better restoring the anatomic footprint of the rotator cuff. Clinical

  9. Repair and tissue engineering techniques for articular cartilage.

    Science.gov (United States)

    Makris, Eleftherios A; Gomoll, Andreas H; Malizos, Konstantinos N; Hu, Jerry C; Athanasiou, Kyriacos A

    2015-01-01

    Chondral and osteochondral lesions due to injury or other pathology commonly result in the development of osteoarthritis, eventually leading to progressive total joint destruction. Although current progress suggests that biologic agents can delay the advancement of deterioration, such drugs are incapable of promoting tissue restoration. The limited ability of articular cartilage to regenerate renders joint arthroplasty an unavoidable surgical intervention. This Review describes current, widely used clinical repair techniques for resurfacing articular cartilage defects; short-term and long-term clinical outcomes of these techniques are discussed. Also reviewed is a developmental pipeline of acellular and cellular regenerative products and techniques that could revolutionize joint care over the next decade by promoting the development of functional articular cartilage. Acellular products typically consist of collagen or hyaluronic-acid-based materials, whereas cellular techniques use either primary cells or stem cells, with or without scaffolds. Central to these efforts is the prominent role that tissue engineering has in translating biological technology into clinical products; therefore, concomitant regulatory processes are also discussed.

  10. Techniques and outcome of repair of cleft of the secondary palate at ...

    African Journals Online (AJOL)

    Background: The technique adopted in the repair of cleft of the secondary palate must not just be based on the choice of the surgeon but on several factors which include the width of the cleft, length of palate and age of the patient. The aim of the article was to document our 4-year experience of the techniques and outcome ...

  11. Is the Dresden technique a mechanical design of choice suitable for the repair of middle third Achilles tendon ruptures? A biomechanical study.

    Science.gov (United States)

    de la Fuente, C; Carreño-Zillmann, G; Marambio, H; Henríquez, H

    2016-01-01

    To compare the mechanical failure of the Dresden technique for Achilles tendon repair with the double modified Kessler technique controlled repair technique. The maximum resistance of the two repair techniques are also compared. A total of 30 Achilles tendon ruptures in bovine specimens were repaired with an Ethibond(®) suture to 4.5cm from the calcaneal insertion. Each rupture was randomly distributed into one of two surgical groups. After repair, each specimen was subjected to a maximum traction test. The mechanical failure (tendon, suture, or knot) rates (proportions) were compared using the exact Fisher test (α=.05), and the maximum resistances using the Student t test (α=.05). There was a difference in the proportions of mechanical failures, with the most frequent being a tendon tear in the Dresden technique, and a rupture of the suture in the Kessler technique. The repair using the Dresden technique performed in the open mode, compared to the Kessler technique, has a more suitable mechanical design for the repair of middle third Achilles tendon ruptures on developing a higher tensile resistance in 58.7%. However, its most common mechanical failure was a tendon tear, which due to inappropriate loads could lead to lengthening of the Achilles tendon. Copyright © 2016 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. No patch technique for complete atrioventricular canal repair.

    Science.gov (United States)

    Aramendi, José Ignacio; Rodriguez, Miguel Angel; Luis, Teresa; Voces, Roberto

    2006-08-01

    We describe our initial experience with a new technique, consisting in direct closure of the ventricular septal defect component of the AV canal, by directly attaching the common bridging leaflets to the crest of the ventricular septum with interrupted sutures. After closure of the cleft, the ostium primum defect was closed with a running suture suturing the border of the septum primum to the newly created AV valve annulus. Three patients were operated upon. There was no mortality. Mean ischemic time was 39 min and mean pump time 77 min. All patients remained in sinus rhythm. At follow-up only trivial or mild mitral regurgitation was observed. This new technique permits the repair of complete AV canal without the need for any patch. It is fast, simple and reproducible.

  13. Advantages of Arthroscopic Rotator Cuff Repair With a Transosseous Suture Technique: A Prospective Randomized Controlled Trial.

    Science.gov (United States)

    Randelli, Pietro; Stoppani, Carlo Alberto; Zaolino, Carlo; Menon, Alessandra; Randelli, Filippo; Cabitza, Paolo

    2017-07-01

    Rotator cuff tear is a common finding in patients with painful, poorly functioning shoulders. The surgical management of this disorder has improved greatly and can now be fully arthroscopic. To evaluate clinical and radiological results of arthroscopic rotator cuff repair using 2 different techniques: single-row anchor fixation versus transosseous hardware-free suture repair. Randomized controlled trial; Level of evidence, 1. Sixty-nine patients with rotator cuff tears were enrolled: 35 patients were operated with metal anchors and 34 with standardized transosseous repair. The patients were clinically evaluated before surgery, during the 28 days after surgery, and at least 1 year after the operation by the use of validated rating scores (Constant score, QuickDASH, and numerical rating scale [NRS]). Final follow-up was obtained at more than 3 years by a QuickDASH evaluation to detect any difference from the previous follow-up. During the follow-up, rotator cuff integrity was determined through magnetic resonance imaging and was classified according to the 5 Sugaya categories. Patients operated with the transosseous technique had significantly less pain, especially from the 15th postoperative day: In the third week, the mean NRS value for the anchor group was 3.00 while that for transosseous group was 2.46 ( P = .02); in the fourth week, the values were 2.44 and 1.76, respectively ( P rotator cuff repair integrity, based on Sugaya magnetic resonance imaging classification, no significant difference was found between the 2 techniques in terms of retear rate ( P = .81). No significant differences were found between the 2 arthroscopic repair techniques in terms of functional and radiological results. However, postoperative pain decreased more quickly after the transosseous procedure, which therefore emerges as a possible improvement in the surgical repair of the rotator cuff. Registration: NCT01815177 ( ClinicalTrials.gov identifier).

  14. Osteochondral defect repair using a polyvinyl alcohol-polyacrylic acid (PVA-PAAc) hydrogel.

    Science.gov (United States)

    Bichara, David A; Bodugoz-Sentruk, Hatice; Ling, Doris; Malchau, Erik; Bragdon, Charles R; Muratoglu, Orhun K

    2014-08-01

    Poly(vinyl alcohol) (PVA) hydrogels can be candidates for articular cartilage repair due to their high water content. We synthesized a PVA-poly(acrylic acid) (PAAc) hydrogel formulation and determined its ability to function as a treatment option for condylar osteochondral (OC) defects in a New Zealand white rabbit (NZWR) model for 12 weeks and 24 weeks. In addition to hydrogel OC implants, tensile bar-shaped hydrogels were also implanted subcutaneously to evaluate changes in mechanical properties as a function of in vivo duration. There were no statistically significant differences (p > 0.05) in the water content measured in the OC hydrogel implant that was harvested after 12 weeks and 24 weeks, and non-implanted controls. There were no statistically significant differences (p > 0.05) in the break stress, strain at break or modulus of the tensile bars either between groups. Histological analysis of the OC defect, synovial capsule and fibrous tissue around the tensile bars determined hydrogel biocompatibility. Twelve-week hydrogels were found to be in situ flush with the articular cartilage; meniscal tissue demonstrated an intact surface. Twenty-four week hydrogels protruded from the defect site due to lack of integration with subchondral tissue, causing fibrillation to the meniscal surface. Condylar micro-CT scans ruled out osteolysis and bone cysts of the subchondral bone, and no PVA-PAAc hydrogel contents were found in the synovial fluid. The PVA-PAAc hydrogel was determined to be fully biocompatible, maintained its properties over time, and performed well at the 12 week time point. Physical fixation of the PVA-PAAc hydrogel to the subchondral bone is required to ensure long-term performance of hydrogel plugs for OC defect repair.

  15. Single site and conventional totally extraperitoneal techniques for uncomplicated inguinal hernia repair: A comparative study.

    Science.gov (United States)

    de Araújo, Felipe Brandão Corrêa; Starling, Eduardo Simão; Maricevich, Marco; Tobias-Machado, Marcos

    2014-10-01

    To demonstrate the feasibility of endoscopic extraperitoneal single site (EESS) inguinal hernia repair and compare it outcomes with the conventional totally extraperitoneal (TEP) technique. TEP inguinal hernia repair is a widely accepted alternative to conventional open technique with several perioperative advantages. Transumbilical laparoendoscopic singlesite surgery (LESS) is an emerging approach and has been reported for a number of surgical procedures with superior aesthetic results but other advantages need to be proven. Thirty-eight uncomplicated inguinal hernias were repaired by EESS approach between January 2010 and January 2011. All procedures were performed through a 25 cm infraumbilical incision using the Alexis wound retractor attached to a surgical glove and three trocars. Body mass index, age, operative time, blood loss, complications, conversion rate, analgesia requirement, hospital stay, return to normal activities and patient satisfaction with aesthetic results were analysed and compared with the last 38 matched-pair group of patients who underwent a conventional TEP inguinal hernia repair by the same surgeon. All procedures were performed successfully with no conversion. In both unilateral and bilateral EESS inguinal repairs, the mean operative time was longer than conventional TEP (55± 20 vs. 40± 15 min, P = 0.049 and 70± 15 vs. 55± 10 min, P = 0.014). Aesthetic result was superior in the EESS group (2.88± 0.43 vs. 2.79± 0.51, P = 0.042). There was no difference between the two approaches regarding blood loss, complications, hospital stay, time until returns to normal activities and analgesic requirement. EESS inguinal hernia repair is safe and effective, with superior cosmetic results in the treatment of uncomplicated inguinal hernias. Other advantages of this new technique still need to be proven.

  16. Risk factors, diagnosis and non-surgical treatment for meniscal tears: evidence and recommendations: a statement paper commissioned by the Danish Society of Sports Physical Therapy (DSSF).

    Science.gov (United States)

    Thorlund, Jonas Bloch; Juhl, Carsten Bogh; Ingelsrud, Lina Holm; Skou, Søren Thorgaard

    2018-05-01

    This statement aimed at summarising and appraising the available evidence for risk factors, diagnostic tools and non-surgical treatments for patients with meniscal tears. We systematically searched electronic databases using a pragmatic search strategy approach. Included studies were synthesised quantitatively or qualitatively, as appropriate. Strength of evidence was determined according to the Grading of Recommendations Assessment Development and Evaluation framework. Low-quality evidence suggested that overweight (degenerative tears, k=3), male sex (k=4), contact and pivoting sports (k=2), and frequent occupational kneeling/squatting (k=3) were risk factors for meniscal tears. There was low to moderate quality evidence for low to high positive and negative predictive values, depending on the underlying prevalence of meniscal tears for four common diagnostic tests (k=15, n=2474). Seven trials investigated exercise versus surgery (k=2) or the effect of surgery in addition to exercise (k=5) for degenerative meniscal tears. There was moderate level of evidence for exercise improving self-reported pain (Effect Size (ES)-0.51, 95% CI -1.16 to 0.13) and function (ES -0.06, 95% CI -0.23 to 0.11) to the same extent as surgery, and improving muscle strength to a greater extent than surgery (ES -0.45, 95% CI -0.62 to -0.29). High-quality evidence showed no clinically relevant effect of surgery in addition to exercise on pain (ES 0.18, 95% 0.05 to 0.32) and function (ES, 0.13 95% CI -0.03 to 0.28) for patients with degenerative meniscal tears. No randomised trials comparing non-surgical treatments with surgery in patients younger than 40 years of age or patients with traumatic meniscal tears were identified. Diagnosis of meniscal tears is challenging as all clinical diagnostic tests have high risk of misclassification. Exercise therapy should be recommended as the treatment of choice for middle-aged and older patients with degenerative meniscal lesions. Evidence on

  17. Congenital superior sternal cleft repair using our modified Sally technique: A case report

    Directory of Open Access Journals (Sweden)

    Tomoyuki Kuwata

    2014-12-01

    Full Text Available We report the case of an 8-month-old male neonate who underwent reconstructive surgery for a congenital superior sternal cleft to decrease the risk of commotio cordis. With regard to use of the Sally technique for the repair of a relatively wide cleft (4 × 4 cm, we were concerned about respiratory problems caused by compression following closure of the sternal halves. By closing the sternal halves imperfectly, elevation of intrapleural pressure can be avoided to some extent. By bridging the surplus resected cartilage from the lower sternum over the gap of the upper sternum, the heart is protected by more rigid material. We recommend our modified Sally technique because it is both flexible and effective for sternal cleft repair.

  18. Does double-row rotator cuff repair improve functional outcome of patients compared with single-row technique? A systematic review.

    Science.gov (United States)

    DeHaan, Alexander M; Axelrad, Thomas W; Kaye, Elizabeth; Silvestri, Lorenzo; Puskas, Brian; Foster, Timothy E

    2012-05-01

    The advantage of single-row versus double-row arthroscopic rotator cuff repair techniques has been a controversial issue in sports medicine and shoulder surgery. There is biomechanical evidence that double-row techniques are superior to single-row techniques; however, there is no clinical evidence that the double-row technique provides an improved functional outcome. When compared with single-row rotator cuff repair, double-row fixation, although biomechanically superior, has no clinical benefit with respect to retear rate or improved functional outcome. Systematic review. The authors reviewed prospective studies of level I or II clinical evidence that compared the efficacy of single- and double-row rotator cuff repairs. Functional outcome scores included the American Shoulder and Elbow Surgeons (ASES) shoulder scale, the Constant shoulder score, and the University of California, Los Angeles (UCLA) shoulder rating scale. Radiographic failures and complications were also analyzed. A test of heterogeneity for patient demographics was also performed to determine if there were differences in the patient profiles across the included studies. Seven studies fulfilled our inclusion criteria. The test of heterogeneity across these studies showed no differences. The functional ASES, Constant, and UCLA outcome scores revealed no difference between single- and double-row rotator cuff repairs. The total retear rate, which included both complete and partial retears, was 43.1% for the single-row repair and 27.2% for the double-row repair (P = .057), representing a trend toward higher failures in the single-row group. Through a comprehensive literature search and meta-analysis of current arthroscopic rotator cuff repairs, we found that the single-row repairs did not differ from the double-row repairs in functional outcome scores. The double-row repairs revealed a trend toward a lower radiographic proven retear rate, although the data did not reach statistical significance. There

  19. Confocal arthroscopy-based patient-specific constitutive models of cartilaginous tissues - II: prediction of reaction force history of meniscal cartilage specimens.

    Science.gov (United States)

    Taylor, Zeike A; Kirk, Thomas B; Miller, Karol

    2007-10-01

    The theoretical framework developed in a companion paper (Part I) is used to derive estimates of mechanical response of two meniscal cartilage specimens. The previously developed framework consisted of a constitutive model capable of incorporating confocal image-derived tissue microstructural data. In the present paper (Part II) fibre and matrix constitutive parameters are first estimated from mechanical testing of a batch of specimens similar to, but independent from those under consideration. Image analysis techniques which allow estimation of tissue microstructural parameters form confocal images are presented. The constitutive model and image-derived structural parameters are then used to predict the reaction force history of the two meniscal specimens subjected to partially confined compression. The predictions are made on the basis of the specimens' individual structural condition as assessed by confocal microscopy and involve no tuning of material parameters. Although the model does not reproduce all features of the experimental curves, as an unfitted estimate of mechanical response the prediction is quite accurate. In light of the obtained results it is judged that more general non-invasive estimation of tissue mechanical properties is possible using the developed framework.

  20. Meniscal replacement using a porous polymer prosthesis : A preliminary study in the dog

    NARCIS (Netherlands)

    Veth, RPH; Jansen, HWB; Nielsen, HKL; deGroot, JH; Pennings, AJ

    A porous polyurethane prosthesis was used to replace the lateral meniscus in the dog. After an initial ingrowth of fibrous tissue, the prostheses became filled with tissue strongly resembling normal meniscal fibrocartilage. Although less severe than seen after total meniscectomy, cartilage

  1. Fetoscopic Open Neural Tube Defect Repair: Development and Refinement of a Two-Port, Carbon Dioxide Insufflation Technique.

    Science.gov (United States)

    Belfort, Michael A; Whitehead, William E; Shamshirsaz, Alireza A; Bateni, Zhoobin H; Olutoye, Oluyinka O; Olutoye, Olutoyin A; Mann, David G; Espinoza, Jimmy; Williams, Erin; Lee, Timothy C; Keswani, Sundeep G; Ayres, Nancy; Cassady, Christopher I; Mehollin-Ray, Amy R; Sanz Cortes, Magdalena; Carreras, Elena; Peiro, Jose L; Ruano, Rodrigo; Cass, Darrell L

    2017-04-01

    To describe development of a two-port fetoscopic technique for spina bifida repair in the exteriorized, carbon dioxide-filled uterus and report early results of two cohorts of patients: the first 15 treated with an iterative technique and the latter 13 with a standardized technique. This was a retrospective cohort study (2014-2016). All patients met Management of Myelomeningocele Study selection criteria. The intraoperative approach was iterative in the first 15 patients and was then standardized. Obstetric, maternal, fetal, and early neonatal outcomes were compared. Standard parametric and nonparametric tests were used as appropriate. Data for 28 patients (22 endoscopic only, four hybrid, two abandoned) are reported, but only those with a complete fetoscopic repair were analyzed (iterative technique [n=10] compared with standardized technique [n=12]). Maternal demographics and gestational age (median [range]) at fetal surgery (25.4 [22.9-25.9] compared with 24.8 [24-25.6] weeks) were similar, but delivery occurred at 35.9 (26-39) weeks of gestation with the iterative technique compared with 39 (35.9-40) weeks of gestation with the standardized technique (Pmet in 9 of 12 (75%) and 3 of 10 (30%), respectively, and 7 of 12 (58%) compared with 2 of 10 (20%) have been treated for hydrocephalus to date. These latter differences were not statistically significant. Fetoscopic open neural tube defect repair does not appear to increase maternal-fetal complications as compared with repair by hysterotomy, allows for vaginal delivery, and may reduce long-term maternal risks. ClinicalTrials.gov, https://clinicaltrials.gov, NCT02230072.

  2. Development of a Chinese version of the Western Ontario Meniscal Evaluation Tool: cross-cultural adaptation and psychometric evaluation.

    Science.gov (United States)

    Tong, W W; Wang, W; Xu, W D

    2016-08-15

    The Western Ontario Meniscal Evaluation Tool (WOMET) is a questionnaire designed to evaluate the health-related quality of life (HRQOL) of patients with meniscal pathology. Our study aims to culturally adapt and validate the WOMET into a Chinese version. We translated the WOMET into Chinese. Then, a total of 121 patients with meniscal pathology were invited to participate in this study. To assess the test-retest reliability, the Chinese version WOMET was completed twice at 7-day intervals by the participants. The construct validity was assessed using Pearson's correlation coefficient or Spearman's correlation to test for correlations among the Chinese version WOMET and the eight domains of Short Form-36 (SF-36), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and the International Knee Documentation Committee (IKDC) score. Responsiveness was tested by comparison of the preoperative and postoperative scores of the Chinese version WOMET. The test-retest reliability of the overall scale and different domains were all found to be excellent. The Cronbach's α was 0.90. The Chinese version WOMET correlated well with other questionnaires which suggested good construct validity. We observed no ceiling and floor effects of the Chinese version WOMET. We also found good responsiveness for the effect size, and the standardized response mean values were 0.86 and 1.11. The Chinese version of the WOMET appears to be reliable and valid in evaluating patients with meniscal pathology.

  3. New Surface-Treatment Technique of Concrete Structures Using Crack Repair Stick with Healing Ingredients.

    Science.gov (United States)

    Ahn, Tae-Ho; Kim, Hong-Gi; Ryou, Jae-Suk

    2016-08-04

    This study focused on the development of a crack repair stick as a new repair method along with self-healing materials that can be used to easily repair the cracks in a concrete structure at the construction site. In developing this new repair technique, the self-healing efficiency of various cementitious materials was considered. Likewise, a crack repair stick was developed to apply to concrete structures with 0.3 mm or lower crack widths. The crack repair stick was made with different materials, such as cement, an expansive material (C 12 A₇), a swelling material, and calcium carbonate, to endow it with a self-healing property. To verify the performance of the crack repair stick for concrete structures, two types of procedures (field experiment and field absorption test) were carried out. As a result of such procedures, it was concluded that the developed crack repair stick could be used on concrete structures to reduce repair expenses and for the improved workability, usability, and serviceability of such structures. On the other hand, to evaluate the self-healing performance of the crack repair stick, various tests were conducted, such as the relative dynamic modulus of elasticity test, the water tightness test, the water permeability test, observation via a microscope, and scanning electron microscope (SEM) analysis. From the results, it is found that water leakage can be prevented and that the durability of a concrete structure can be improved through self-healing. Also, it was verified that the cracks were perfectly closed after 28 days due to application of the crack repair stick. These results indicate the usability of the crack repair stick for concrete structures, and its self-healing efficiency.

  4. Clinical Results of Flexor Tendon Repair in Zone II Using a six Strand Double Loop Technique.

    Science.gov (United States)

    Savvidou, Christiana; Tsai, Tsu-Min

    2015-06-01

    The purpose of this study is to report the clinical results after repair of flexor tendon zone II injuries utilizing a 6-strand double-loop technique and early post-operative active rehabilitation. We retrospectively reviewed 22 patients involving 51 cases with zone II flexor tendon repair using a six strand double loop technique from September 1996 to December 2012. Most common mechanism of injuries was sharp lacerations (86.5 %). Tendon injuries occurred equally in manual and non-manual workers and were work-related in 33 % of the cases. The Strickland score for active range of motion (ROM) postoperatively was excellent and good in the majority of the cases (81 %). The rupture rate was 1.9 %. The six strand double loop technique for Zone II flexor tendon repair leads to good and excellent motion in the majority of patients and low re- rupture rate. It is clinically effective and allows for early postoperative active rehabilitation.

  5. Lineage plasticity and cell biology of fibrocartilage and hyaline cartilage: Its significance in cartilage repair and replacement

    International Nuclear Information System (INIS)

    Freemont, Anthony J.; Hoyland, Judith

    2006-01-01

    Cartilage repair is a major goal of modern tissue engineering. To produce novel engineered implants requires a knowledge of the basic biology of the tissues that are to be replaced or reproduced. Hyaline articular cartilage and meniscal fibrocartilage are two tissues that have excited attention because of the frequency with which they are damaged. A basic strategy is to re-engineer these tissues ex vivo by stimulating stem cells to differentiate into the cells of the mature tissue capable of producing an intact functional matrix. In this brief review, the sources of cells for tissue engineering cartilage and the culture conditions that have promoted differentiation are discussed within the context of natural cartilage repair. In particular, the role of cell density, cytokines, load, matrices and oxygen tension are discussed

  6. Lineage plasticity and cell biology of fibrocartilage and hyaline cartilage: Its significance in cartilage repair and replacement

    Energy Technology Data Exchange (ETDEWEB)

    Freemont, Anthony J. [Regenerative Medicine Research Group, University of Manchester, England (United Kingdom)]. E-mail: Tony.freemont@man.ac.uk; Hoyland, Judith [Regenerative Medicine Research Group, University of Manchester, England (United Kingdom)

    2006-01-15

    Cartilage repair is a major goal of modern tissue engineering. To produce novel engineered implants requires a knowledge of the basic biology of the tissues that are to be replaced or reproduced. Hyaline articular cartilage and meniscal fibrocartilage are two tissues that have excited attention because of the frequency with which they are damaged. A basic strategy is to re-engineer these tissues ex vivo by stimulating stem cells to differentiate into the cells of the mature tissue capable of producing an intact functional matrix. In this brief review, the sources of cells for tissue engineering cartilage and the culture conditions that have promoted differentiation are discussed within the context of natural cartilage repair. In particular, the role of cell density, cytokines, load, matrices and oxygen tension are discussed.

  7. One-flap Palatoplasty: A Cohort Study to Evaluate a Technique for Unilateral Cleft Palate Repair

    Directory of Open Access Journals (Sweden)

    Percy Rossell-Perry, PhD, FACS

    2015-04-01

    Conclusions: Use of a 1-flap technique for unilateral cleft palate repair allowed us to achieve results comparable to those of a 2-flap technique in terms of postoperative fistula development and hypernasal speech. Additional studies are required to evaluate the effect of this technique on palatal growth.

  8. A biomechanical comparison of 2 transosseous-equivalent double-row rotator cuff repair techniques using bioabsorbable anchors: cyclic loading and failure behavior.

    Science.gov (United States)

    Spang, Jeffrey T; Buchmann, Stefan; Brucker, Peter U; Kouloumentas, Panos; Obst, Tobias; Schröder, Manuel; Burgkart, Rainer; Imhoff, Andreas B

    2009-08-01

    A novel double-row configuration was compared with a traditional double-row configuration for rotator cuff repair. In 10 matched-pair sheep shoulders in vitro repair was performed with either a double-row technique with corkscrew suture anchors for the medial row and insertion anchors for the lateral row (group A) or a double-row technique with a new tape-like suture material with insertion anchors for both the medial and lateral rows (group B). Each specimen underwent cyclic loading from 10 to 150 N for 100 cycles, followed by unidirectional failure testing. Gap formation and strain within the repair area for the first and last cycles were analyzed with a video digitizing system, and stiffness and failure load were determined from the load-elongation curve. The results were similar for the 2 repair types. There was no significant difference between the ultimate failure loads of the 2 techniques (421 +/- 150 N in group A and 408 +/- 66 N in group B, P = .31) or the stiffness of the 2 techniques (84 +/- 26 N/mm in group A and 99 +/- 20 N/mm in group B, P = .07). In addition, gap formation was not different between the repair types. Strain over the repair area was also not different between the repair types. Both tested rotator cuff repair techniques had high failure loads, limited gap formation, and acceptable strain patterns. No significant difference was found between the novel and conventional double-row repair types. Two double-row techniques-one with corkscrew suture anchors for the medial row and insertion anchors for the lateral row and one with insertion anchors for both the medial and lateral rows-provided excellent biomechanical profiles at time 0 for double-row repairs in a sheep model. Although the sheep model may not directly correspond to in vivo conditions, all-insertion anchor double-row constructs are worthy of further investigation.

  9. Treatment of Painful, Irreparable Partial Meniscal Defects With a Polyurethane Scaffold: Midterm Clinical Outcomes and Survival Analysis.

    Science.gov (United States)

    Dhollander, Aad; Verdonk, Peter; Verdonk, René

    2016-10-01

    A biodegradable polyurethane scaffold was designed to fulfill a challenging clinical need in the treatment of patients with painful, irreparable partial meniscal defects. The use of an acellular polyurethane scaffold for new tissue generation in irreparable, partial meniscal defects provides both midterm pain relief and improved functionality. Case series; Level of evidence, 4. A total of 44 patients with irreparable, partial meniscal defects (29 medial and 15 lateral) were implanted with a polyurethane scaffold in a prospective, single-arm proof-of-principle study with a minimum 5-year follow-up. Clinical outcomes were measured with the visual analog scale (VAS) for pain, International Knee Documentation Committee (IKDC), and Knee injury and Osteoarthritis Outcome Score (KOOS) at baseline and at 2- and 5-year follow-up. Magnetic resonance imaging (MRI) was used to evaluate the meniscal implant and cartilage status of the index compartment. Kaplan-Meier time-to-treatment failure distributions were also performed. Removal of the scaffold, conversion to a meniscal transplant, or unicompartmental/total knee arthroplasty was used as endpoints. Seven patients were lost to follow-up (15.9%). The patients who participated in this study showed significant clinical improvement after surgery (mean [±SD] at baseline, 2 years, and 5 years: 56.2 ± 21.6, 24.6 ± 22.7, and 19.3 ± 26.9, respectively [VAS]; 206.5 ± 79.7, 329.8 ± 108.9, and 333.6 ± 112.2, respectively [total KOOS]). MRI of the scaffolds showed a smaller sized implant when compared with the native meniscus with an irregular surface at 2- and 5-year follow-up. A stable cartilage status of the index compartment at 5-year follow-up was demonstrated in 46.7% of patients compared with the baseline status. During the follow-up period, 62.2% of the implants survived. At final follow-up, 66.7% of the medial scaffolds were still functioning versus 53.8% of the lateral scaffolds. A polyurethane meniscal implant can

  10. Multilevel Spondylolysis Repair Using the "Smiley Face" Technique with 3-Dimensional Intraoperative Spinal Navigation.

    Science.gov (United States)

    Voisin, Mathew R; Witiw, Christopher D; Deorajh, Ryan; Guha, Daipayan; Oremakinde, Adetunji; Wang, Shelly; Yang, Victor

    2018-01-01

    Multilevel spondylolysis is a rare cause of progressive lower back pain, and patients who fail conservative management are treated surgically. Direct repair methods can maintain mobility and lead to decreased morbidity compared with spinal fusion in single-level spondylolysis. In this paper, we present a patient with nonadjacent multilevel spondylolysis who underwent the "smiley face" technique of direct multilevel repair without fusion using 3-dimensional intraoperative spinal navigation. Bilateral spondylolysis at L3 and L5 with associated spondylolisthesis in a 50-year-old male was repaired using the "smiley face" technique. Patient-reported outcomes, including the Oswestry Disability Index (ODI) and visual analog scale scores for back and leg pain, were assessed preoperatively along with 6 weeks and 4 months postoperatively. Postoperative computed tomography imaging showed precise screw insertion and rod placement along with stable hardware alignment in follow-up imaging. The patient's ODI and lower back visual analog scale scores decreased from 25 to 8 and 7.5 to 4, respectively, correlating to an excellent outcome on ODI. Direct repair and avoidance of fusion is possible and can provide good functional outcomes in patients with nonadjacent multilevel spondylolysis and associated spondylolisthesis. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. The Tilburg double blind randomised controlled trial comparing inguinal hernia repair according to Lichtenstein and the transinguinal preperitoneal technique

    Directory of Open Access Journals (Sweden)

    Gerritsen Pieter G

    2009-09-01

    Full Text Available Abstract Background Anterior open treatment of the inguinal hernia with a tension free mesh has reduced the incidence of recurrence and direct postoperative pain. The Lichtenstein procedure rules nowadays as reference technique for hernia treatment. Not recurrences but chronic pain is the main postoperative complication in inguinal hernia repair after Lichtenstein's technique. Preliminary experiences with a soft mesh placed in the preperitoneal space showed good results and less chronic pain. Methods The TULIP is a double-blind randomised controlled trial in which 300 patients will be randomly allocated to anterior inguinal hernia repair according to Lichtenstein or the transinguinal preperitoneal technique with soft mesh. All unilateral primary inguinal hernia patients eligible for operation who meet inclusion criteria will be invited to participate in this trial. The primary endpoint will be direct postoperative- and chronic pain. Secondary endpoints are operation time, postoperative complications, hospital stay, costs, return to daily activities (e.g. work and recurrence. Both groups will be evaluated. Success rate of hernia repair and complications will be measured as safeguard for quality. To demonstrate that inguinal hernia repair according to the transinguinal preperitoneal (TIPP technique reduces postoperative pain to Discussion The TULIP trial is aimed to show a reduction in postoperative chronic pain after anterior hernia repair according to the transinguinal preperitoneal (TIPP technique, compared to Lichtenstein. In our hypothesis the TIPP technique reduces chronic pain compared to Lichtenstein. Trial registration ISRCTN 93798494

  12. Knee function and knee muscle strength in middle-aged patients with degenerative meniscal tears eligible for arthroscopic partial meniscectomy

    DEFF Research Database (Denmark)

    Stensrud, Silje; Risberg, May Arna; Roos, Ewa M.

    2014-01-01

    BACKGROUND: Functional limitations exist postmeniscectomy, but preoperative data are scarce. PURPOSE: To examine knee function, knee muscle strength and performance in middle-aged patients with degenerative meniscal tears, eligible for arthroscopic partial meniscectomy. STUDY DESIGN: Cross......-sectional study. METHODS: Eighty-two participants with MRI verified degenerative meniscal tear (35% women, mean age 49 years) answered the Knee injury and Osteoarthritis Outcome Score (KOOS) and were tested for isokinetic knee muscle strength and lower extremity performance (one-leg hop for distance, 6 m timed...

  13. Robotic Inguinal Hernia Repair: Technique and Early Experience.

    Science.gov (United States)

    Arcerito, Massimo; Changchien, Eric; Bernal, Oscar; Konkoly-Thege, Adam; Moon, John

    2016-10-01

    Laparoscopic inguinal hernia repair has been shown to have multiple advantages compared with open repair such as less postoperative pain and earlier resume of daily activities with a comparable recurrence rate. We speculate robotic inguinal hernia repair may yield equivalent benefits, while providing the surgeon added dexterity. One hundred consecutive robotic inguinal hernia repairs with mesh were performed with a mean age of 56 years (25-96). Fifty-six unilateral hernias and 22 bilateral hernias were repaired amongst 62 males and 16 females. Polypropylene mesh was used for reconstruction. All but, two patients were completed robotically. Mean operative time was 52 minutes per hernia repair (45-67). Five patients were admitted overnight based on their advanced age. Regular diet was resumed immediately. Postoperative pain was minimal and regular activity was achieved after an average of four days. One patient recurred after three months in our earlier experience and he was repaired robotically. Mean follow-up time was 12 months. These data, compared with laparoscopic approach, suggest similar recurrence rates and postoperative pain. We believe comparative studies with laparoscopic approach need to be performed to assess the role robotic surgery has in the treatment of inguinal hernia repair.

  14. IVO develops a new repair technique for underwater sites. Viscous doughlike substance underwater cracks

    Energy Technology Data Exchange (ETDEWEB)

    Klingstedt, G.; Leisio, C. [ed.

    1998-07-01

    A viscous sealant is revolutionizing repair of the stone and concrete masonry of underwater dams, bridges and canals. There is now no need for expensive and time-consuming cofferdams, since a diver can extrude quick-setting mortar into underwater structures needing repair. This technique has worked well in recent years in various parts of Finland even in strongly flowing water. IVO experts are now starting to look more beyond the borders of Finland

  15. Effect of meniscus replacement fixation technique on restoration of knee contact mechanics and stability.

    Science.gov (United States)

    D'Lima, D D; Chen, P C; Kessler, O; Hoenecke, H R; Colwell, C W

    2011-06-01

    The menisci are important biomechanical components of the knee. We developed and validated a finite element model of meniscal replacement to assess the effect of surgical fixation technique on contact behavior and knee stability. The geometry of femoral and tibial articular cartilage and menisci was segmented from magnetic resonance images of a normal cadaver knee using MIMICS (Materialise, Leuven, Belgium). A finite element mesh was generated using HyperWorks (Altair Inc, Santa Ana, CA). A finite element solver (Abaqus v6.9, Simulia, Providence, RI) was used to compute contact area and stresses under axial loading and to assess stability (reaction force generated during anteroposterior translation of the femur). The natural and surgical attachments of the meniscal horns and peripheral rim were simulated using springs. After total meniscectomy, femoral contact area decreased by 26% with a concomitant increase in average contact stresses (36%) and peak contact stresses (33%). Replacing the meniscus without suturing the horns did little to restore femoral contact area. Suturing the horns increased contact area and reduced peak contact stresses. Increasing suture stiffness correlated with increased meniscal contact stresses as a greater proportion of tibiofemoral load was transferred to the meniscus. A small incremental benefit was seen of simulated bone plug fixation over the suture construct with the highest stiffness (50 N/mm). Suturing the rim did little to change contact conditions. The nominal anteroposterior stiffness reduced by 3.1 N/mm after meniscectomy. In contrast to contact area and stress, stiffness of the horn fixation sutures had a smaller effect on anteroposterior stability. On the other hand suturing the rim of the meniscus affected anteroposterior stability to a much larger degree. This model emphasizes the importance of the meniscus in knee biomechanics. Appropriate meniscal replacement fixation techniques are likely to be critical to the clinical

  16. Fibrochondrogenic potential of synoviocytes from osteoarthritic and normal joints cultured as tensioned bioscaffolds for meniscal tissue engineering in dogs

    Directory of Open Access Journals (Sweden)

    Jennifer J. Warnock

    2014-09-01

    Full Text Available Meniscal tears are a common cause of stifle lameness in dogs. Use of autologous synoviocytes from the affected stifle is an attractive cell source for tissue engineering replacement fibrocartilage. However, the diseased state of these cells may impede in vitro fibrocartilage formation. Synoviocytes from 12 osteoarthritic (“oaTSB” and 6 normal joints (“nTSB” were cultured as tensioned bioscaffolds and compared for their ability to synthesize fibrocartilage sheets. Gene expression of collagens type I and II were higher and expression of interleukin-6 was lower in oaTSB versus nTSB. Compared with nTSB, oaTSB had more glycosaminoglycan and alpha smooth muscle staining and less collagen I and II staining on histologic analysis, whereas collagen and glycosaminoglycan quantities were similar. In conclusion, osteoarthritic joint—origin synoviocytes can produce extracellular matrix components of meniscal fibrocartilage at similar levels to normal joint—origin synoviocytes, which makes them a potential cell source for canine meniscal tissue engineering.

  17. Kissing contusion between the posterolateral tibial plateau and lateral femoral condyle: associated ligament and meniscal tears

    International Nuclear Information System (INIS)

    Hong, Hyun Pyo; Lee, Jae Gue; Park, Ji Seon; Ryu, Kyung Nam

    2004-01-01

    Kissing contusion between the posterolateral tibial plateau and lateral femoral condyle is frequently found in association with a tear of the anterior cruciate liagment (ACL). The purpose of this study was to determine which ligamentous and meniscal tears are associated with kissing contusion. We retrospectively reviewed the findings depicted by 323 consecutive MR images of the knee and confirmed at arthroscopy. For the diagnosis of disruption, ligaments, medial menisci (MM) and lateral menisci (LM) were evaluated using accepted criteria. We compared the prevalence and location of meniscal and ligamentous tears between group I (44 knees with kissing contusion) and group II (279 knees without kissing contusion). For statistical analysis the chi-square test was used. ACLs were torn in all 44 knees (100%) with kissing contusion, and 78 (28%) of 279 without kissing contusion. There were ten medial collateral ligament (MCL) tears (23%) in group I, and 17 MCL tears (6%), five lateral collateral ligament (LCL) tears (2%) and ten posterior cruciate ligament (PCL) tears (4%) in group II. In group I, meniscal tears were found in 22 MM (50%) and in 19 LM (43%), while in group II, they occurred in 128 MM (46%) and 128 LM (46%), In group I, 17 (77%) of 22 MM tears and 13 (68%) of 19 LM tears were located in the posterior horn, while in group II, the corresponding figures were 97/128 (76%) and 60 of 128 (47%). The differing prevalence of ACL and MCL tears between the groups was statistically significant (p 0.05). Although kissing contusion was a highly specific sign of ACL tears, its presence was also significant among MCL tears. There was no significant difference in meniscal tears with or without kissing contusion

  18. Complications after pectus excavatum repair using pectus bars in adolescents and adults: risk comparisons between age and technique groups.

    Science.gov (United States)

    Choi, Soohwan; Park, Hyung Joo

    2017-10-01

    To compare the complications associated with age and technique groups in patients undergoing pectus excavatum (PE) repair. The data of 994 patients who underwent PE repair from March 2011 to December 2015 were retrospectively reviewed. Mean age was 9.59 years (range 31 months-55 years), and 756 patients were men (76.1%). The age groups were defined as follows: Group 1, Group 2, 5-9 years; Group 3, 10-14 years; Group 4, 15-17 years; Group 5, 18-19 years; Group 6, 20-24 years; and Group 7, >24 years. The technique groups were defined as follows: Group 1, patients who underwent repair with claw fixators and hinge plates; Group 2, patients who underwent repair with our 'bridge' technique. Complications were compared between age groups and technique groups. No cases of mortality occurred. Complication rates in the age groups 1-7 were 5.4%, 3.6%, 12.1%, 18.2%, 17.3%, 13.9% and 16.7%, respectively. The complication rate tripled after the age of 10. In multivariable analysis, odds ratio of Groups 4, 5 and 7 and asymmetric types were 3.04, 2.81, 2.97 and 1.70 (P Group 1 was 0.8% (6 of 780). No bar dislocations occurred in technique Group 2. Older patients have more asymmetric pectus deformity and they are also risk factors for complications following PE repair. The bridge technique provides a bar dislocation rate of 0%, even in adult patients. This procedure seems to reduce or prevent major complications following PE repair. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  19. Radiographic joint space narrowing in osteoarthritis of the knee: relationship to meniscal tears and duration of pain

    International Nuclear Information System (INIS)

    Chan, Wing P.; Huang, Guo-Shu; Hsu, Shu-Mei; Chang, Yue-Cune; Ho, Wei-Pin

    2008-01-01

    The objective of this study was to assess, with knee radiography, joint space narrowing (JSN) and its relationship to meniscal tears, anterior cruciate ligament (ACL) ruptures, articular cartilage erosion, and duration of pain in patients with knee osteoarthritis. A total of 140 patients who had knee osteoarthritis and underwent primary total knee replacement (TKR) surgery, with unicompartmental medial tibiofemoral JSN (grade 1 or greater) and normal lateral compartments, were recruited. Polytomous logistic regression was used to assess the relationship between JSN and risk factors. All patients with JSN were categorized as grade 1 (n=14, 10.0%), grade 2 (n=64, 45.7%), or grade 3 (n=62, 44.3%). Women presented with indications for a TKR at a younger age than men (mean age, 69 vs 73 years, P<0.05). There were 123 (87.9%) meniscal tears and 58 (41.4%) partial (insufficient or attenuated ACL fibers) and 10 (7.1%) complete ACL ruptures; 115 of 134 (85.8%) patients had moderate to severe cartilage erosion. A higher grade of JSN was correlated with a higher frequency of meniscal tears [odds ratio (OR) 6.00, 95% CI 1.29-27.96 for grade 2 vs grade 1 JSN] and duration of knee pain (OR 1.25, 95% CI 1.01-1.53 for grade 3 vs grade 1 JSN). A higher grade of JSN was not correlated with a higher frequency of ACL rupture or articular cartilage erosion. A higher grade of JSN is associated with a higher frequency of meniscal tears and long duration of knee pain in patients with knee osteoarthritis. (orig.)

  20. Radiographic joint space narrowing in osteoarthritis of the knee: relationship to meniscal tears and duration of pain

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Wing P. [Taipei Medical University, Department of Radiology, School of Medicine, Taipei (China); Taipei Medical University-Wan Fang Hospital, Department of Radiology, Taipei (China); Huang, Guo-Shu [Tri-Service General Hospital, National Defense Medical Center, Department of Radiology, Taipei (China); Hsu, Shu-Mei [Taipei Medical University, Department of Radiology, School of Medicine, Taipei (China); National Taiwan University, Department of Public Health, Taipei (China); Chang, Yue-Cune [Tamkang University, Department of Mathematics, Taipei County (China); Ho, Wei-Pin [Taipei Medical University-Wan Fang Hospital, Department of Orthopedic Surgery, Taipei (China)

    2008-10-15

    The objective of this study was to assess, with knee radiography, joint space narrowing (JSN) and its relationship to meniscal tears, anterior cruciate ligament (ACL) ruptures, articular cartilage erosion, and duration of pain in patients with knee osteoarthritis. A total of 140 patients who had knee osteoarthritis and underwent primary total knee replacement (TKR) surgery, with unicompartmental medial tibiofemoral JSN (grade 1 or greater) and normal lateral compartments, were recruited. Polytomous logistic regression was used to assess the relationship between JSN and risk factors. All patients with JSN were categorized as grade 1 (n=14, 10.0%), grade 2 (n=64, 45.7%), or grade 3 (n=62, 44.3%). Women presented with indications for a TKR at a younger age than men (mean age, 69 vs 73 years, P<0.05). There were 123 (87.9%) meniscal tears and 58 (41.4%) partial (insufficient or attenuated ACL fibers) and 10 (7.1%) complete ACL ruptures; 115 of 134 (85.8%) patients had moderate to severe cartilage erosion. A higher grade of JSN was correlated with a higher frequency of meniscal tears [odds ratio (OR) 6.00, 95% CI 1.29-27.96 for grade 2 vs grade 1 JSN] and duration of knee pain (OR 1.25, 95% CI 1.01-1.53 for grade 3 vs grade 1 JSN). A higher grade of JSN was not correlated with a higher frequency of ACL rupture or articular cartilage erosion. A higher grade of JSN is associated with a higher frequency of meniscal tears and long duration of knee pain in patients with knee osteoarthritis. (orig.)

  1. Readability of Online Sources Regarding Meniscal Tears.

    Science.gov (United States)

    Hodax, Jonathan D; Baird, Grayson L; McBride, Trevor; Owens, Brett D

    2017-09-01

    Meniscal injuries are extremely common, with an incidence of 8.3 per 1,000 person/years in young, active individuals. Patients often turn to the internet to glean information about their injuries, and even to guide decision making about treatment. Much research has been done demonstrating that a reading level of eighth grade or lower is appropriate for accurately communicating written information to patients, yet medical practitioners often fail to meet this requirement. To better examine the information patients receive about meniscal injuries, we set out to evaluate the reading level and content of three commonly used search terms on the three search engines with the largest market share. The authors examined the keywords "meniscus tear," "meniscus tear treatment," and "knee pain meniscus" on the three highest market share search engines. The top 10 results from each search were included, and redundancies identified. Unique Web sites were evaluated for source, word count, reading level, and content including advertisements, diagrams, photographs, nonoperative and operative options, and accurate medical information. A total of 23 unique Web sites were identified in our search, including 13 public education sources, 6 academic institutions, and 4 private physicians/groups. Average grade levels of articles ranged from 9.4 to 14.2 (mean, 11.14; standard deviation [SD] 1.46), and Flesch-Kincaid reading ease scores ranged from 23.9 to 68.7 (mean, 55.31; SD, 10.11). Pages from public sources required the highest level of readability (11.6, 95% confidence interval [CI]: 9.8-13.2), which was significantly higher than private (11.0, 95% CI: 9.3, 12.7]) and academic (10.9, 95% CI: 8.9-12.9), p  = 0.007 and p  = 0.002, respectively. Further efforts to make appropriate health information available to patients are needed. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  2. The Relationship between Chondromalacia Patella, Medial Meniscal Tear and Medial Periarticular Bursitis in Patients with Osteoarthritis.

    Science.gov (United States)

    Resorlu, Mustafa; Doner, Davut; Karatag, Ozan; Toprak, Canan Akgun

    2017-12-01

    This study investigated the presence of bursitis in the medial compartment of the knee (pes anserine, semimembranosus-tibial collateral ligament, and medial collateral ligament bursa) in osteoarthritis, chondromalacia patella and medial meniscal tears. Radiological findings of 100 patients undergoing magnetic resonance imaging with a preliminary diagnosis of knee pain were retrospectively evaluated by two radiologists. The first radiologist assessed all patients in terms of osteoarthritis, chondromalacia patella and medial meniscal tear. The second radiologist was blinded to these results and assessed the presence of bursitis in all patients. Mild osteoarthritis (grade I and II) was determined in 55 patients and severe osteoarthritis (grade III and IV) in 45 cases. At retropatellar cartilage evaluation, 25 patients were assessed as normal, while 29 patients were diagnosed with mild chondromalacia patella (grade I and II) and 46 with severe chondromalacia patella (grade III and IV). Medial meniscus tear was determined in 51 patients. Severe osteoarthritis and chondromalacia patella were positively correlated with meniscal tear (p chondromalacia patella (p = 0.023 and p = 0.479, respectively). Evaluation of lateral compartment bursae revealed lateral collateral ligament bursitis in 2 patients and iliotibial bursitis in 5 patients. We observed a greater prevalence of bursitis in the medial compartment of the knee in patients with severe osteoarthritis and medial meniscus tear.

  3. Meniscal T1rho and T2 measured with 3.0T MRI increases directly after running a marathon

    Energy Technology Data Exchange (ETDEWEB)

    Stehling, Christoph [University of California, Musculoskeletal and Quantitative Imaging Group (MQIR), Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); University of Muenster, Department of Clinical Radiology, Muenster (Germany); Luke, Anthony [University of California, Department of Orthopedic Surgery, San Francisco, CA (United States); Stahl, Robert [University of California, Musculoskeletal and Quantitative Imaging Group (MQIR), Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Ludwig Maximilians University of Munich, Department of Clinical Radiology, Munich (Germany); Baum, Thomas; Joseph, Gabby; Pan, Judong; Link, Thomas M. [University of California, Musculoskeletal and Quantitative Imaging Group (MQIR), Department of Radiology and Biomedical Imaging, San Francisco, CA (United States)

    2011-06-15

    To prospectively evaluate changes in T1rho and T2 relaxation time in the meniscus using 3.0 T MRI in asymptomatic knees of marathon runners and to compare these findings with those of age-matched healthy subjects. Thirteen marathon runners underwent 3.0 T MRI including T1rho and T2 mapping sequences before, 48-72 h after, and 3 months after competition. Ten controls were examined at baseline and after 3 months. All images were analyzed by two musculoskeletal radiologists identifying and grading cartilage, meniscal, ligamentous. and other knee abnormalities with WORMS scores. Meniscal segmentation was performed to generate T1rho and T2 maps in six compartments. No differences in morphological knee abnormalities were found before and after the marathon. However, all marathon runners showed a significant increase in T1rho and T2 values after competition in all meniscus compartments (p < 0.0001), which may indicate changes in the biochemical composition of meniscal tissue. While T2 values decreased after 3 months T1rho values remained at a high level, indicating persisting changes in the meniscal matrix composition after a marathon. T2 values in menisci have the potential to be used as biomarkers for identifying reversible meniscus matrix changes indicating potential tissue damage. T1rho values need further study, but may be a valuable marker for diagnosing early, degenerative changes in the menisci following exercise. (orig.)

  4. Efficacy of bone marrow-stimulating technique in rotator cuff repair.

    Science.gov (United States)

    Bilsel, Kerem; Yildiz, Fatih; Kapicioglu, Mehmet; Uzer, Gokcer; Elmadag, Mehmet; Pulatkan, Anil; Esrefoglu, Mukaddes; Bozdag, Ergun; Milano, Giuseppe

    2017-08-01

    This study used a chronic rotator cuff (RC) tear model to investigate the effect of microfracture as a bone marrow-stimulating (BMS) technique for RC healing. A chronic retracted RC tendon tear model was created bilaterally in the subscapularis tendons of 20 New Zealand rabbits. The tendons were repaired after 8 weeks using a single-row configuration. Tendons in the right shoulder were repaired in standard fashion (control group). Microfractures were performed in the left shoulders before repair (microfracture group). The animals were euthanized 8 and 16 weeks after repair. The repaired tendons were tested biomechanically for their ultimate failure load, linear stiffness, and elongation at failure. Gross and histologic evaluations of the tendon-to-bone healing were evaluated. Macroscopically, subscapularis tendons were attached on the lesser tuberosity. In the microfracture group, collagen fibers were organized in relatively thicker bundles. The mean ultimate failure load of the microfracture group was significantly greater at 8 weeks (148.4 ± 31 N vs. 101.4 ± 26 N, respectively; P = .011) and 16 weeks (155 ± 30 N vs. 114.9 ± 25 N, respectively; P = .017) after repair. There were no significant differences between the groups for linear stiffness at 8 weeks (15.9 ± 2.7 N/mm vs. 15.8 ± 1.3 N/mm, respectively; P = .798) and 16 weeks (16.9 ± 4.3 N/mm vs. 17.1 ± 3.6 N/mm, respectively, P = .848) and elongation at failure at 8 weeks (4.7 ± 1.1 mm vs. 4.7 ± 1.3 mm, respectively; P = .848) and 16 weels (4.8 ± 1.5 mm vs. 4.9 ± 0.9 mm, respectively; P = .749). The microfracture on the tuberosity of the repaired chronic rotator cuff tear promoted dynamic tendon healing with significantly increased ultimate force to failure and with thicker collagen bundles and more fibrocartilage histologically at 8 weeks. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of

  5. Determination of damage and In vivo DNA repairing through the unicellular in gel electrophoresis technique

    International Nuclear Information System (INIS)

    Mendiola C, M.T.; Morales R, P.

    1997-01-01

    The experimental conditions were standardized for the unicellular in gel electrophoresis technique setting up (EUG) at the Cellular Radiobiology laboratory. Preliminary experiments were realized with human cells and mouse which were exposed to ionizing radiation or hydroxide peroxide (H 2 O 2 ) to induce DNA damage and to verify the technique performance. It was analysed the In vivo repairing kinetics of induced damage by gamma radiation in mouse leukocytes which were exposed to 137 Cs source and taking samples of peripheric blood of the tail of each mouse at different exposure times and processing them for EUG. In function of the cells proportion with damage in each time it was determined the existence of fast repairing mechanism at the first 15 minutes followed by a slight increase in the damage and a late repairing stage between 30 and 90 minutes. It was analysed this behavior and the potentiality of this In vivo system. (Author)

  6. Bonding and fusion of meniscus fibrocartilage using a novel chondroitin sulfate bone marrow tissue adhesive.

    Science.gov (United States)

    Simson, Jacob A; Strehin, Iossif A; Allen, Brian W; Elisseeff, Jennifer H

    2013-08-01

    The weak intrinsic meniscus healing response and technical challenges associated with meniscus repair contribute to a high rate of repair failures and meniscectomies. Given this limited healing response, the development of biologically active adjuncts to meniscal repair may hold the key to improving meniscal repair success rates. This study demonstrates the development of a bone marrow (BM) adhesive that binds, stabilizes, and stimulates fusion at the interface of meniscus tissues. Hydrogels containing several chondroitin sulfate (CS) adhesive levels (30, 50, and 70 mg/mL) and BM levels (30%, 50%, and 70%) were formed to investigate the effects of these components on hydrogel mechanics, bovine meniscal fibrochondrocyte viability, proliferation, matrix production, and migration ability in vitro. The BM content positively and significantly affected fibrochondrocyte viability, proliferation, and migration, while the CS content positively and significantly affected adhesive strength (ranged from 60±17 kPa to 335±88 kPa) and matrix production. Selected material formulations were translated to a subcutaneous model of meniscal fusion using adhered bovine meniscus explants implanted in athymic rats and evaluated over a 3-month time course. Fusion of adhered meniscus occurred in only the material containing the highest BM content. The technology can serve to mechanically stabilize the tissue repair interface and stimulate tissue regeneration across the injury site.

  7. Biomechanical comparison of single-row, double-row, and transosseous-equivalent repair techniques after healing in an animal rotator cuff tear model.

    Science.gov (United States)

    Quigley, Ryan J; Gupta, Akash; Oh, Joo-Han; Chung, Kyung-Chil; McGarry, Michelle H; Gupta, Ranjan; Tibone, James E; Lee, Thay Q

    2013-08-01

    The transosseous-equivalent (TOE) rotator cuff repair technique increases failure loads and contact pressure and area between tendon and bone compared to single-row (SR) and double-row (DR) repairs, but no study has investigated if this translates into improved healing in vivo. We hypothesized that a TOE repair in a rabbit chronic rotator cuff tear model would demonstrate a better biomechanical profile than SR and DR repairs after 12 weeks of healing. A two-stage surgical procedure was performed on 21 New Zealand White Rabbits. The right subscapularis tendon was transected and allowed to retract for 6 weeks to simulate a chronic tear. Repair was done with the SR, DR, or TOE technique and allowed to heal for 12 weeks. Cyclic loading and load to failure biomechanical testing was then performed. The TOE repair showed greater biomechanical characteristics than DR, which in turn were greater than SR. These included yield load (p repair of a chronic, retracted rotator cuff tear, the TOE technique was the strongest biomechanical construct after healing followed by DR with SR being the weakest. Copyright © 2013 Orthopaedic Research Society.

  8. The success of 6-hour hospital discharge on patients having vaginal repair operations using a new conscious sedation technique.

    Science.gov (United States)

    Hill, N; Gupta, A; Zakaryan, A; Morey, R

    2011-01-01

    Anterior and posterior repair are standard surgical techniques for treatment of vaginal prolapse. These procedures are performed traditionally under general anaesthetic or spinal anaesthetic and usually require overnight admission in the hospital. We describe our case series of 40 patients who underwent anterior (18/40), posterior (20/40) or combined repair (2/40) under local anaesthetic and conscious sedation (Remifentanyl). The majority (35/40) were performed in the day-case surgery unit and 95% patients were discharged within 6 hours of the operation, with no complications. All the patients were satisfied with the anaesthetic technique. We concluded that our technique of vaginal repair avoids the risk of general and spinal anaesthetic. The majority of operations can be performed as day cases with good patient satisfaction and without increasing risks to the patients. This technique has potential significant financial saving for the hospitals.

  9. Brazing and diffusion bonding processes as available repair techniques for gas turbine blades and nozzles

    International Nuclear Information System (INIS)

    Mazur, Z.

    1997-01-01

    The conventionally welding methods are not useful for repair of heavily damaged gas turbine blades and nozzles. It includes thermal fatigue and craze cracks, corrosion, erosion and foreign object damage, which extend to the large areas. Because of required extensive heat input and couponing, it can cause severe distortion of the parts and cracks in the heat affected zone, and can made the repair costs high. For these cases, the available repair methods of gas turbine blades and nozzles, include brazing and diffusion bonding techniques are presented. Detailed analysis of the brazing and diffusion bonding processes applied for gas turbine blades repair with all elements which presented. Detailed analysis of the brazing and diffusion bonding processes applied for gas turbine blades repair with all elements which have influence to get sound joint is carried out. Depend of kind of blades and nozzle damage or deterioration registered a different methods of brazing and diffusion bonding applicability is presented. (Author) 65 refs

  10. DNA repair protocols

    DEFF Research Database (Denmark)

    Bjergbæk, Lotte

    In its 3rd edition, this Methods in Molecular Biology(TM) book covers the eukaryotic response to genomic insult including advanced protocols and standard techniques in the field of DNA repair. Offers expert guidance for DNA repair, recombination, and replication. Current knowledge of the mechanisms...... that regulate DNA repair has grown significantly over the past years with technology advances such as RNA interference, advanced proteomics and microscopy as well as high throughput screens. The third edition of DNA Repair Protocols covers various aspects of the eukaryotic response to genomic insult including...... recent advanced protocols as well as standard techniques used in the field of DNA repair. Both mammalian and non-mammalian model organisms are covered in the book, and many of the techniques can be applied with only minor modifications to other systems than the one described. Written in the highly...

  11. A 5‑year Review of Darning Technique of Inguinal Hernia Repair

    African Journals Online (AJOL)

    modes of presentation,[8,9] and in many hospitals where the experience ... will be ideal. This study aims to present our experience with the use of the. Darning technique for repair of inguinal hernia in a Nigerian ... Study Design: A descriptive retrospective study ... site infection was the most common complication occurring in.

  12. Direct surgical repair of spondylolysis in athletes: indications, techniques, and outcomes.

    Science.gov (United States)

    Drazin, Doniel; Shirzadi, Ali; Jeswani, Sunil; Ching, Harry; Rosner, Jack; Rasouli, Alexandre; Kim, Terrence; Pashman, Robert; Johnson, J Patrick

    2011-11-01

    Athletes present with back pain as a common symptom. Various sports involve repetitive hyperextension of the spine along with axial loading and appear to predispose athletes to the spinal pathology spondylolysis. Many athletes with acute back pain require nonsurgical treatment methods; however, persistent recurrent back pain may indicate degenerative disc disease or spondylolysis. Young athletes have a greater incidence of spondylolysis. Surgical solutions are many, and yet there are relatively few data in the literature on both the techniques and outcomes of spondylolytic repair in athletes. In this study, the authors undertook a review of the surgical techniques and outcomes in the treatment of symptomatic spondylolysis in athletes. A systematic review of the MEDLINE and PubMed databases was performed using the following key words to identify articles published between 1950 and 2011: "spondylolysis," "pars fracture," "repair," "athlete," and/or "sport." Papers on both athletes and nonathletes were included in the review. Articles were read for data on methodology (retrospective vs prospective), type of treatment, number of patients, mean patient age, and mean follow-up. Eighteen articles were included in the review. Eighty-four athletes and 279 nonathletes with a mean age of 20 and 21 years, respectively, composed the population under review. Most of the fractures occurred at L-5 in both patient groups, specifically 96% and 92%, respectively. The average follow-up period was 26 months for athletes and 86 months for nonathletes. According to the modified Henderson criteria, 84% (71 of 84) of the athletes returned to their sports activities. The time intervals until their return ranged from 5 to 12 months. For a young athlete with a symptomatic pars defect, any of the described techniques of repair would probably produce acceptable results. An appropriate preoperative workup is important. The ideal candidate is younger than 20 years with minimal or no listhesis and

  13. Integrated technique of planning the capital repair of residential buildings and objects of transport infrastructure

    Science.gov (United States)

    Dement'eva, Marina

    2017-10-01

    The paper presents the results of a comparative analysis of two fundamentally different methods for planning capital repairs of objects of transport infrastructure and residential development. The first method was based on perspective long-term plans. Normative service life were the basis for planning the periodicity of repairs. The second method was based on the performance of repairs in fact of the onset of the malfunction. Problems of financing repair work, of the uneven aging of constructs and engineering systems, different wear mechanism in different conditions of exploitation, absence of methods of planning repairs of administrative and production buildings (depots, stations, etc.) justify the need to optimize methods of planning the repair and the relevance of this paper. The aim of the study was to develop the main provisions of an integrated technique for planning the capital repair of buildings of any functional purpose, which combines the advantages of each of the discussed planning methods. For this purpose, the consequences of technical and economic risk were analyzed of the buildings, including stations, depots, transport transfer hubs, administrative buildings, etc when choosing different planning methods. One of the significant results of the study is the possibility of justifying the optimal period of capital repairs on the basis of the proposed technical and economic criteria. The adjustment of the planned repair schedule is carried out taking into account the reliability and cost-effectiveness of the exploitation process.

  14. The contribution of 3D quantitative meniscal and cartilage measures to variation in normal radiographic joint space width—Data from the Osteoarthritis Initiative healthy reference cohort

    International Nuclear Information System (INIS)

    Roth, Melanie; Wirth, Wolfgang; Emmanuel, Katja; Culvenor, Adam G.; Eckstein, Felix

    2017-01-01

    Objective: To explore to what extent three-dimensional measures of the meniscus and femorotibial cartilage explain the variation in medial and lateral femorotibial radiographic joint space width (JSW), in healthy men and women. Methods: The right knees of 87 Osteoarthritis Initiative healthy reference participants (no symptoms, radiographic signs or risk factors of osteoarthritis; 37 men, 50 women; age 55.0 ± 7.6; BMI 24.4 ± 3.1) were assessed. Quantitative measures of subregional femorotibial cartilage thickness and meniscal position and morphology were computed from segmented magnetic resonance images. Minimal and medial/lateral fixed-location JSW were determined from fixed-flexion radiographs. Correlation and regression analyses were used to explore the contribution of demographic, cartilage and meniscal parameters to JSW in healthy subjects. Results: The correlation with (medial) minimal JSW was somewhat stronger for cartilage thickness (0.54 ≤ r ≤ 0.67) than for meniscal (−0.31 ≤ r ≤ 0.50) or demographic measures (−0.15 ≤ r ≤ 0.48), in particular in men. In women, in contrast, the strength of the correlations of cartilage thickness and meniscal measures with minimal JSW were in the same range. Fixed-location JSW measures showed stronger correlations with cartilage thickness (r ≥ 0.68 medially; r ≥ 0.59 laterally) than with meniscal measures (r ≤ |0.32| medially; r ≤ |0.32| laterally). Stepwise regression models revealed that meniscal measures added significant independent information to the total variance explained in minimal JSW (adjusted multiple r 2 = 58%) but not in medial or lateral fixed-location JSW (r 2 = 60/51%, respectively). Conclusions: In healthy subjects, minimal JSW was observed to reflect a combination of cartilage and meniscal measures, particularly in women. Fixed-location JSW, in contrast, was found to be dominated by variance in cartilage thickness in both men and women, with somewhat higher correlations between

  15. On failure of the pruning technique in "error repair in shift-reduce parsers"

    NARCIS (Netherlands)

    Bertsch, E; Nederhof, MJ

    A previous article presented a technique to compute the least-cost error repair by incrementally generating configurations that result from inserting and deleting tokens in a syntactically incorrect input. An additional mechanism to improve the run-time efficiency of this algorithm by pruning some

  16. Culture of equine fibroblast-like synoviocytes on synthetic tissue scaffolds towards meniscal tissue engineering: a preliminary cell-seeding study

    Directory of Open Access Journals (Sweden)

    Jennifer J. Warnock

    2014-04-01

    coating of PGA scaffolds; cellularity was inversely proportional to the concentration of PLLA used. PLLA coating did not prevent dissolution of the PGA scaffolds. All cell scaffold types and culture conditions produced non-uniform cellular distribution.Discussion/Conclusion. FLS-seeding of PGA scaffolds cultured in a rotating bioreactor resulted in the most optimal cell and matrix characteristics seen in this study. Cells grew only in the pores of the OPLA sponge, and could not adhere to the PLLA coating of PGA scaffold, due to the hydrophobic property of PLA. While PGA culture in a bioreactor produced measureable GAG, no culture technique produced visible collagen. For this reason, and due to the dissolution of PGA scaffolds, the culture conditions and scaffolds described here are not recommended for inducing fibrochondrogenesis in equine FLS for meniscal tissue engineering.

  17. The Relationship between Chondromalacia Patella, Medial Meniscal Tear and Medial Periarticular Bursitis in Patients with Osteoarthritis

    Science.gov (United States)

    Doner, Davut; Karatag, Ozan; Toprak, Canan Akgun

    2017-01-01

    Abstract Background This study investigated the presence of bursitis in the medial compartment of the knee (pes anserine, semimembranosus-tibial collateral ligament, and medial collateral ligament bursa) in osteoarthritis, chondromalacia patella and medial meniscal tears. Patients and methods Radiological findings of 100 patients undergoing magnetic resonance imaging with a preliminary diagnosis of knee pain were retrospectively evaluated by two radiologists. The first radiologist assessed all patients in terms of osteoarthritis, chondromalacia patella and medial meniscal tear. The second radiologist was blinded to these results and assessed the presence of bursitis in all patients. Results Mild osteoarthritis (grade I and II) was determined in 55 patients and severe osteoarthritis (grade III and IV) in 45 cases. At retropatellar cartilage evaluation, 25 patients were assessed as normal, while 29 patients were diagnosed with mild chondromalacia patella (grade I and II) and 46 with severe chondromalacia patella (grade III and IV). Medial meniscus tear was determined in 51 patients. Severe osteoarthritis and chondromalacia patella were positively correlated with meniscal tear (p chondromalacia patella (p = 0.023 and p = 0.479, respectively). Evaluation of lateral compartment bursae revealed lateral collateral ligament bursitis in 2 patients and iliotibial bursitis in 5 patients. Conclusions We observed a greater prevalence of bursitis in the medial compartment of the knee in patients with severe osteoarthritis and medial meniscus tear. PMID:29333118

  18. Novel technique for repairing posterior medial meniscus root tears using porcine knees and biomechanical study.

    Directory of Open Access Journals (Sweden)

    Jia-Lin Wu

    Full Text Available Transtibial pullout suture (TPS repair of posterior medial meniscus root (PMMR tears was shown to achieve good clinical outcomes. The purpose of this study was to compare biomechanically, a novel technique designed to repair PMMR tears using tendon graft (TG and conventional TPS repair. Twelve porcine tibiae (n = 6 each TG group: flexor digitorum profundus tendon was passed through an incision in the root area, created 5 mm postero-medially along the edge of the attachment area. TPS group: a modified Mason-Allen suture was created using no. 2 FiberWire. The tendon grafts and sutures were threaded through the bone tunnel and then fixed to the anterolateral cortex of the tibia. The two groups underwent cyclic loading followed by a load-to-failure test. Displacements of the constructs after 100, 500, and 1000 loading cycles, and the maximum load, stiffness, and elongation at failure were recorded. The TG technique had significantly lower elongation and higher stiffness compared with the TPS. The maximum load of the TG group was significantly lower than that of the TPS group. Failure modes for all specimens were caused by the suture or graft cutting through the meniscus. Lesser elongation and higher stiffness of the constructs in TG technique over those in the standard TPS technique might be beneficial for postoperative biological healing between the meniscus and tibial plateau. However, a slower rehabilitation program might be necessary due to its relatively lower maximum failure load.

  19. An experimental study of reconstructive procedures in lesions of the meniscus. Use of synovial flaps and carbon fiber implants for artificially made lesions in the meniscus of the rabbit

    NARCIS (Netherlands)

    Veth, R. P.; den Heeten, G. J.; Jansen, H. W.; Nielsen, H. K.

    1983-01-01

    Reconstructive procedures were investigated in meniscal lesions in 25 rabbits. Large meniscal defects were repaired with either a synovial flap or a carbon fiber implant. Fibrous tissue healing with occasional areas of fibrocartilage occurred after both types of reconstruction. When carbon fibers

  20. MRI as an accurate tool for the diagnosis and characterization of different knee joint meniscal injuries

    Directory of Open Access Journals (Sweden)

    Ayman F. Ahmed

    2017-12-01

    Conclusion: MRI of the knee will give the orthopedic surgeons ability to select suitable treatment and arthroscopic interference for their patients. MRI has high accuracy in meniscal tears diagnosis allowing accurate grading of them.

  1. Delay in surgery predisposes to meniscal and chondral injuries in anterior cruciate ligament deficient knees

    Directory of Open Access Journals (Sweden)

    Ravi Gupta

    2016-01-01

    Conclusion: Surgical delay predicts an increase in medial meniscal and lateral articular injuries justifying early rather than delayed reconstruction in ACL deficient knees. Increasing age is positively related to intraarticular injuries while females are more susceptible to lateral articular injuries.

  2. Critical and subcritical damage monitoring of bonded composite repairs using innovative non-destructive techniques

    Science.gov (United States)

    Grammatikos, S. A.; Kordatos, E. Z.; Aggelis, D. G.; Matikas, T. E.; Paipetis, A. S.

    2012-04-01

    Infrared Thermography (IrT) has been shown to be capable of detecting and monitoring service induced damage of repair composite structures. Full-field imaging, along with portability are the primary benefits of the thermographic technique. On-line lock-in thermography has been reported to successfully monitor damage propagation or/and stress concentration in composite coupons, as mechanical stresses in structures induce heat concentration phenomena around flaws. During mechanical fatigue, cyclic loading plays the role of the heating source and this allows for critical and subcritical damage identification and monitoring using thermography. The Electrical Potential Change Technique (EPCT) is a new method for damage identification and monitoring during loading. The measurement of electrical potential changes at specific points of Carbon Fiber Reinforced Polymers (CFRPs) under load are reported to enable the monitoring of strain or/and damage accumulation. Along with the aforementioned techniques Finally, Acoustic Emission (AE) method is well known to provide information about the location and type of damage. Damage accumulation due to cyclic loading imposes differentiation of certain parameters of AE like duration and energy. Within the scope of this study, infrared thermography is employed along with AE and EPCT methods in order to assess the integrity of bonded repair patches on composite substrates and to monitor critical and subcritical damage induced by the mechanical loading. The combined methodologies were effective in identifying damage initiation and propagation of bonded composite repairs.

  3. The use of MRI in the investigation of lateral meniscal tear post medial unicompartmental knee replacement

    Directory of Open Access Journals (Sweden)

    Sanil H. Ajwani, MBChB, BSc (Hons, MRCS

    2015-06-01

    Full Text Available The evaluation of lateral knee pain in patients with a medial unicompartmental knee replacement (UKR is complex. The native lateral compartment structures are prone to the same injuries as patients with normal knees. Historical reports of lateral meniscal injury post medial UKR have argued MRI evaluation is obsolete due to artefact caused by the prosthesis. We report a case of lateral meniscal injury in a patient two years after successful medial UKR. We identified the offending pathology via utilization of MRI scanners adopting metal artefact reduction sequences (MARS. The MARS MRI protocol helps clinicians accurately and non-invasively evaluate soft tissue structures in knees with metal prostheses. It also allows surgeons to accurately counsel patients and provides a higher degree of certainty in treating the pathology.

  4. Comparison of Passive Stiffness Changes in the Supraspinatus Muscle after Double-row and Knotless Transosseous-equivalent Rotator Cuff Repair Techniques: A Cadaveric Study

    Science.gov (United States)

    Hatta, Taku; Giambini, Hugo; Hooke, Alexander W.; Zhao, Chunfeng; Sperling, John W.; Steinmann, Scott P.; Yamamoto, Nobuyuki; Itoi, Eiji; An, Kai-Nan

    2016-01-01

    Purpose To investigate the alteration of passive stiffness in the supraspinatus muscle after double-row (DR) and knotless transosseous-equivalent (KL-TOE) repair techniques, using the shear wave elastography (SWE) in cadavers with rotator cuff tears. We also aimed to compare altered muscular stiffness after these repairs to that obtained from shoulders with intact rotator cuff tendon. Methods Twelve fresh-frozen cadaveric shoulders with rotator cuff tear (tear size; small [6], medium-large [6]) were used. Passive stiffness of four anatomical regions in the supraspinatus muscle was measured based on an established SWE method. Each specimen underwent DR and KL-TOE footprint repairs at 30° glenohumeral abduction. SWE values, obtained at 0°, 10°, 20°, 30°, 60°, and 90° abduction, were assessed in 3 different conditions: preoperative (torn) and postoperative conditions with the 2 techniques. The increase ratio of SWE values after repair was compared among the four regions to assess stiffness distribution. In addition, SWE values were obtained on 12 shoulders with intact rotator cuff tendons as control. Results In shoulders with medium-large size tears, supraspinatus muscles showed an increased passive stiffness after rotator cuff repairs, and this was significantly observed at adducted positions. KL-TOE repair showed uniform stiffness changes among the four regions of the supraspinatus muscle (mean, 189-218% increase after repair), whereas, DR repair caused a significantly heterogeneous stiffness distribution within the muscle (mean, 187-319% after repair, P = 0.002). Although a repair-induced increase in muscle stiffness was observed also in small size tear, there were no significant differences in repaired stiffness changes between DR and KL-TOE (mean, 127-138% and 127-130% after repairs, respectively). Shoulders with intact rotator cuff tendon showed uniform SWE values among the four regions of the supraspinatus muscle (mean, 38.2-43.0 kPa). Conclusion Passive

  5. Difficulties and Problematic Steps in Teaching the Onstep Technique for Inguinal Hernia Repair, Results from a Focus Group Interview

    DEFF Research Database (Denmark)

    Andresen, Kristoffer; Laursen, Jannie; Rosenberg, Jacob

    2016-01-01

    technique for inguinal hernia repair, seen from the instructor's point of view. Methods. We designed a qualitative study using a focus group to allow participants to elaborate freely and facilitate a discussion. Participants were surgeons with extensive experience in performing the Onstep technique from...... course should preferably have experience with other types of hernia repairs. If trainees are inexperienced, the training setup should be a traditional step-by-step programme. A training setup should consist of an explanation of the technique with emphasis on anatomy and difficult parts of the procedure...

  6. Correlation between histological outcome and surgical cartilage repair technique in the knee: A meta-analysis.

    Science.gov (United States)

    DiBartola, Alex C; Everhart, Joshua S; Magnussen, Robert A; Carey, James L; Brophy, Robert H; Schmitt, Laura C; Flanigan, David C

    2016-06-01

    Compare histological outcomes after microfracture (MF), autologous chondrocyte implantation (ACI), and osteochondral autograft transfer (OATS). Literature review using PubMed MEDLINE, SCOPUS, Cumulative Index for Nursing and Allied Health Literature (CINAHL), and Cochrane Collaboration Library. Inclusion criteria limited to English language studies International Cartilage Repair Society (ICRS) grading criteria for cartilage analysis after ACI (autologous chondrocyte implantation), MF (microfracture), or OATS (osteochondral autografting) repair techniques. Thirty-three studies investigating 1511 patients were identified. Thirty evaluated ACI or one of its subtypes, six evaluated MF, and seven evaluated OATS. There was no evidence of publication bias (Begg's p=0.48). No statistically significant correlation was found between percent change in clinical outcome and percent biopsies showing ICRS Excellent scores (R(2)=0.05, p=0.38). Percent change in clinical outcome and percent of biopsies showing only hyaline cartilage were significantly associated (R(2)=0.24, p=0.024). Mean lesion size and histological outcome were not correlated based either on percent ICRS Excellent (R(2)=0.03, p=0.50) or percent hyaline cartilage only (R(2)=0.01, p=0.67). Most common lesion location and histological outcome were not correlated based either on percent ICRS Excellent (R(2)=0.03, p=0.50) or percent hyaline cartilage only (R(2)=0.01, p=0.67). Microfracture has poorer histologic outcomes than other cartilage repair techniques. OATS repairs primarily are comprised of hyaline cartilage, followed closely by cell-based techniques, but no significant difference was found cartilage quality using ICRS grading criteria among OATS, ACI-C, MACI, and ACI-P. IV, meta-analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Morphologic characterization of meniscal root ligaments in the human knee with magnetic resonance microscopy at 11.7 and 3 T

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Eric Y.; Chung, Christine B. [VA San Diego Healthcare System, Department of Radiology, San Diego, CA (United States); University of California, San Diego Medical Center, Department of Radiology, San Diego, CA (United States); Biswas, Reni; DiCamillo, Paul; Statum, Sheronda; Tafur, Monica; Bydder, Graeme M. [University of California, San Diego Medical Center, Department of Radiology, San Diego, CA (United States)

    2014-10-15

    To determine the feasibility of using MR microscopy to characterize the root ligaments of the human knee at both ultra-high-field (11.7 T) and high-field (3 T) strengths. Seven fresh cadaveric knees were used for this study. Six specimens were imaged at 11.7 T and one specimen at 3 T using isotropic or near-isotropic voxels. Histologic correlation was performed on the posteromedial root ligament of one specimen. Meniscal root ligament shape, signal intensity, and ultrastructure were characterized. High-resolution, high-contrast volumetric images were generated from both MR systems. Meniscal root ligaments were predominantly oval in shape. Increased signal intensity was most evident at the posteromedial and posterolateral root ligaments. On the specimen that underwent histologic preparation, increased signal intensity corresponded to regions of enthesis fibrocartilage. Collagen fascicles were continuous between the menisci and root ligaments. Predominantly horizontal meniscal radial tie fibers continued into the root ligaments as vertical endoligaments. MR microscopy can be used to characterize and delineate the distinct ultrastructure of the root ligaments on both ultra-high-field- and high-field-strength MR systems. (orig.)

  8. The relationship between chondromalacia patella, medial meniscal tear and medial periarticular bursitis in patients with osteoarthritis

    Directory of Open Access Journals (Sweden)

    Resorlu Mustafa

    2017-11-01

    Full Text Available This study investigated the presence of bursitis in the medial compartment of the knee (pes anserine, semimembranosus-tibial collateral ligament, and medial collateral ligament bursa in osteoarthritis, chondromalacia patella and medial meniscal tears.

  9. Flexor tendon repair: a comparative study between a knotless barbed suture repair and a traditional four-strand monofilament suture repair.

    LENUS (Irish Health Repository)

    Joyce, C W

    2014-01-01

    We compared the tensile strength of a novel knotless barbed suture method with a traditional four-strand Adelaide technique for flexor tendon repairs. Forty fresh porcine flexor tendons were transected and randomly assigned to one of the repair groups before repair. Biomechanical testing demonstrated that the tensile strengths between both tendon groups were very similar. However, less force was required to create a 2 mm gap in the four-strand repair method compared with the knotless barbed technique. There was a significant reduction in the cross-sectional area in the barbed suture group after repair compared with the Adelaide group. This would create better gliding within the pulley system in vivo and could decrease gapping and tendon rupture.

  10. Clinical and radiographic outcomes of meniscus surgery and future targets for biologic intervention: A review of data from the MOON Group.

    Science.gov (United States)

    Westermann, Robert W; Jones, Morgan; Wasserstein, David; Spindler, Kurt P

    Meniscus injury and treatment occurred with the majority of anterior cruciate ligament reconstructions (ACLR) in the multicenter orthopedic outcomes (MOON) cohort. We describe the patient-reported outcomes, radiographic outcomes, and predictors of pain from meniscus injuries and treatment in the setting of ACLR. Patient-reported outcomes improve significantly following meniscus repair with ACLR, but differences exist based on the meniscus injury laterally (medial or lateral). Patients undergoing medial meniscus repair have worse patient-reported outcomes and more pain compared to those with uninjured menisci. However, lateral meniscal tears can be repaired with similar outcomes as uninjured menisci. Medial meniscal treatment (meniscectomy or repair) results in a significant loss of joint space at 2 years compared to uninjured menisci. Menisci treated with excision had a greater degree of joint space loss compared to those treated with repair. Clinically significant knee pain is more common following injuries to the medial meniscus and increased in patients who undergo early re-operation after initial ACLR. Future research efforts aimed at improving outcomes after combined ACLR and meniscus treatment should focus on optimizing biologic and mechanical environments that promote healing of medial meniscal tears sustained during ACL injury.

  11. Biomechanical comparison of a single-row versus double-row suture anchor technique for rotator cuff repair.

    Science.gov (United States)

    Kim, David H; Elattrache, Neal S; Tibone, James E; Jun, Bong-Jae; DeLaMora, Sergai N; Kvitne, Ronald S; Lee, Thay Q

    2006-03-01

    Reestablishment of the native footprint during rotator cuff repair has been suggested as an important criterion for optimizing healing potential and fixation strength. A double-row rotator cuff footprint repair will demonstrate superior biomechanical properties compared with a single-row repair. Controlled laboratory study. In 9 matched pairs of fresh-frozen cadaveric shoulders, the supraspinatus tendon from 1 shoulder was repaired with a double-row suture anchor technique: 2 medial anchors with horizontal mattress sutures and 2 lateral anchors with simple sutures. The tendon from the contralateral shoulder was repaired using a single lateral row of 2 anchors with simple sutures. Each specimen underwent cyclic loading from 10 to 180 N for 200 cycles, followed by tensile testing to failure. Gap formation and strain over the footprint area were measured using a video digitizing system; stiffness and failure load were determined from testing machine data. Gap formation for the double-row repair was significantly smaller (P row repair for the first cycle (1.67 +/- 0.75 mm vs 3.10 +/- 1.67 mm, respectively) and the last cycle (3.58 +/- 2.59 mm vs 7.64 +/- 3.74 mm, respectively). The initial strain over the footprint area for the double-row repair was nearly one third (P row repair. Adding a medial row of anchors increased the stiffness of the repair by 46% and the ultimate failure load by 48% (P row repair improved initial strength and stiffness and decreased gap formation and strain over the footprint when compared with a single-row repair. To achieve maximal initial fixation strength and minimal gap formation for rotator cuff repair, reconstructing the footprint attachment with 2 rows of suture anchors should be considered.

  12. The contribution of 3D quantitative meniscal and cartilage measures to variation in normal radiographic joint space width—Data from the Osteoarthritis Initiative healthy reference cohort

    Energy Technology Data Exchange (ETDEWEB)

    Roth, Melanie, E-mail: melanie.roth@pmu.ac.at [Institute of Anatomy, Paracelsus Medical University Salzburg & Nuremberg, Strubergasse 21, 5020, Salzburg (Austria); Wirth, Wolfgang, E-mail: wolfgang.wirth@pmu.ac.at [Institute of Anatomy, Paracelsus Medical University Salzburg & Nuremberg, Strubergasse 21, 5020, Salzburg (Austria); Chondrometrics GmbH, Ulrichshöglerstrasse 23, 83404, Ainring (Germany); Emmanuel, Katja, E-mail: katja.emmanuel@icloud.com [Institute of Anatomy, Paracelsus Medical University Salzburg & Nuremberg, Strubergasse 21, 5020, Salzburg (Austria); Department of Orthopedics and Traumatology, Paracelsus Medical University, Müllner Hauptstraße 48, 5020, Salzburg (Austria); Culvenor, Adam G., E-mail: adam.culvenor@pmu.ac.at [Institute of Anatomy, Paracelsus Medical University Salzburg & Nuremberg, Strubergasse 21, 5020, Salzburg (Austria); School of Allied Health, La Trobe University, Plenty Road, Bundoora, 3086, Victoria (Australia); Eckstein, Felix, E-mail: felix.eckstein@pmu.ac.at [Institute of Anatomy, Paracelsus Medical University Salzburg & Nuremberg, Strubergasse 21, 5020, Salzburg (Austria); Chondrometrics GmbH, Ulrichshöglerstrasse 23, 83404, Ainring (Germany)

    2017-02-15

    Objective: To explore to what extent three-dimensional measures of the meniscus and femorotibial cartilage explain the variation in medial and lateral femorotibial radiographic joint space width (JSW), in healthy men and women. Methods: The right knees of 87 Osteoarthritis Initiative healthy reference participants (no symptoms, radiographic signs or risk factors of osteoarthritis; 37 men, 50 women; age 55.0 ± 7.6; BMI 24.4 ± 3.1) were assessed. Quantitative measures of subregional femorotibial cartilage thickness and meniscal position and morphology were computed from segmented magnetic resonance images. Minimal and medial/lateral fixed-location JSW were determined from fixed-flexion radiographs. Correlation and regression analyses were used to explore the contribution of demographic, cartilage and meniscal parameters to JSW in healthy subjects. Results: The correlation with (medial) minimal JSW was somewhat stronger for cartilage thickness (0.54 ≤ r ≤ 0.67) than for meniscal (−0.31 ≤ r ≤ 0.50) or demographic measures (−0.15 ≤ r ≤ 0.48), in particular in men. In women, in contrast, the strength of the correlations of cartilage thickness and meniscal measures with minimal JSW were in the same range. Fixed-location JSW measures showed stronger correlations with cartilage thickness (r ≥ 0.68 medially; r ≥ 0.59 laterally) than with meniscal measures (r ≤ |0.32| medially; r ≤ |0.32| laterally). Stepwise regression models revealed that meniscal measures added significant independent information to the total variance explained in minimal JSW (adjusted multiple r{sup 2} = 58%) but not in medial or lateral fixed-location JSW (r{sup 2} = 60/51%, respectively). Conclusions: In healthy subjects, minimal JSW was observed to reflect a combination of cartilage and meniscal measures, particularly in women. Fixed-location JSW, in contrast, was found to be dominated by variance in cartilage thickness in both men and women, with somewhat higher correlations

  13. [STUDY ON WOUND HEALING AFTER Sommerlad TECHNIQUE REPAIR OF ISOLATED CLEFT PALATE].

    Science.gov (United States)

    Lu, Yong; Shi, Bing; Wang, Zhiyong; Zhan, Xin

    2014-07-01

    To study the inhibitory effect of Sommerlad technique on the growth of the maxilla by comparing the wound healing between Sommerlad and Von Langenbeck techniques in repair of isolated cleft palate. A retrospective cohort study was conducted on 54 patients with isolated cleft palate who received palatoplasty with levator veli palatini retropositioning according to Sommerlad between June 2005 and August 2011 as trial group; 89 cleft patients received Von Langenbeck technique repair between June 2003 and September 2006 as control group. There was no significant difference in gender and age between 2 groups (P > 0.05). The operation time, intraoperative blood loss, body temperature, and fever were recorded and compared; the wound healing was observed, and the palatal mucosa was graded according to Karsten standard. The operation time of trial group [(72.2 ± 5.5) minutes] was significantly longer than that of control group [(58.1 ± 6.8) minutes] (t = 4.494, P = 0.000); the intraoperative blood loss of trial group [(18.6 ± 6.5) mL] was significantly less than that of control group [(34.2 ± 10.2) mL] (t = 2.447, P = 0.000). Within postoperative 48 hours, the highest body temperature was 36.6-37.6°C (mean, 36.9°C) in trial group, and was 36.8-38.2°C (mean, 37.3°C) in control group; fever occurred in 5 patients (9.3%) of trial group and 21 patients (23.6%) of control group, showing significant difference (χ2 = 4.640, P = 0.030). The patients were followed up 3-18 months (mean, 9 months) in the trial group, and 3-6 years (mean, 4 years) in the control group. Scar was rated as level 0, level 1, and level 2 in 38, 13, and 3 cases of trial group, and in 6, 35, and 48 cases of control group, showing significant difference (Z = -7.785, P = 0.000). The isolated cleft palate repair using Sommerlad technique has the advantages of less injury and less scar tissue, indicating no inhibitory effect on the growth of the maxilla.

  14. [PART-KESSLER TECHNIQUE WITH SUTURE ANCHOR IN REPAIR OF SPONTANEOUS Achilles TENDON RUPTURE].

    Science.gov (United States)

    Qi, Jie; Duan, Liang; Li, Weiwei; Wei, Wenbo

    2016-02-01

    To summarize the application and experience of repairing spontaneous Achilles tendon rupture by part-Kessler technique with suture anchor. Between January 2011 and December 2013, 31 patients with spontaneous Achilles tendon rupture were treated by part-Kessler technique with suture anchor. Of 31 cases, 23 were male and 8 were female, aged 16-53 years (mean, 38 years). The left side was involved in 15 cases and the right side in 16 cases. The causes of injury included sudden heel pain and walking weakness during sports in 22 cases; no surefooted down-stairs, slip, and carrying heavy loads in 9 cases. The distance from broken site to the calcaneus adhension of Achilles tendon was 3-6 cm (mean, 4.2 cm). The time from injury to operation was 7 hours to 4 days (mean, 36.8 hours). All incisions healed by first intention without nerve injury or adhering with skin. The patients were followed up 6-24 months (mean, 15 months). All patients could complete 25 times heel raising without difficulty at 6 months after operation. No Achilles tendon rupture occurred again during follow-up. At 6 months after operation, the range of motion of the ankle joint in dorsiflexion and plantar flexion showed no significant difference between normal and affected sides (t=0.648, P=0.525; t=0.524, P=0.605). The circumference of the affected leg was significantly smaller than that of normal leg at 6 months after operation (t=2.074, P=0.041), but no significant difference was found between affected and normal sides at 12 months after operation (t=0.905, P=0.426). The American Orthopedic Foot and Ankle Society (AOFAS) scores at 6, 12, 18, and 24 months after operation were significantly higher than preoperative score (P0.05). Repairing spontaneous Achilles tendon rupture by part-Kessler technique with suture anchor can supply strong strain and decrease the shear forces of suture. So part-Kessler technique with suture anchor is successful in repairing spontaneous Achilles tendon rupture.

  15. Modified suture-bridge technique to prevent a marginal dog-ear deformity improves structural integrity after rotator cuff repair.

    Science.gov (United States)

    Ryu, Keun Jung; Kim, Bang Hyun; Lee, Yohan; Lee, Yoon Seok; Kim, Jae Hwa

    2015-03-01

    The arthroscopic suture-bridge technique has proved to provide biomechanically firm fixation of the torn rotator cuff to the tuberosity by increasing the footprint contact area and pressure. However, a marginal dog-ear deformity is encountered not infrequently when this technique is used, impeding full restoration of the torn cuff. To evaluate the structural and functional outcomes of the use of a modified suture-bridge technique to prevent a marginal dog-ear deformity compared with a conventional suture-bridge method in rotator cuff repair. Cohort study; Level of evidence 2. A consecutive series of 71 patients aged 50 to 65 years who underwent arthroscopic rotator cuff repair for full-thickness medium-sized to massive tears was evaluated. Patients were divided into 2 groups according to repair technique: a conventional suture-bridge technique (34 patients; group A) versus a modified suture-bridge technique to prevent a marginal dog-ear deformity (37 patients; group B). Radiographic evaluations included postoperative cuff integrity using MRI. Functional evaluations included pre- and postoperative range of motion (ROM), pain visual analog scale (VAS), the University of California, Los Angeles (UCLA) shoulder rating scale, the Constant score, and the American Shoulder and Elbow Surgeons (ASES) score. All patients were followed up clinically at a minimum of 1 year. When the 2 surgical techniques were compared, postoperative structural integrity by Sugaya classification showed the distribution of types I:II:III:IV:V to be 4:20:2:4:4 in group A and 20:12:4:0:1 in group B. More subjects in group B had a favorable Sugaya type compared with group A (P bridge technique repairs were found in the retear group (P = .03). There were significant differences between healed and retear groups in functional outcome scores, with worse results in the retear group. A modified suture-bridge technique to prevent a marginal dog-ear deformity provided better structural outcomes than a

  16. Cell biological and biomechanical evaluation of two different fixation techniques for rotator cuff repair.

    Science.gov (United States)

    Klinger, H-M; Koelling, S; Baums, M H; Kahl, E; Steckel, H; Smith, M M; Schultz, W; Miosge, N

    2009-06-01

    Our objective was to evaluate the cell biology and biomechanical aspects of the healing process after two different techniques in open rotator cuff surgery - double-loaded bio-absorbable suture anchors combined with so-called arthroscopic Mason-Allen stitches (AAMA) and a trans-osseous suture technique combined with traditional modified Mason-Allen stitches (SMMA). Thirty-six mature sheep were randomized into two repair groups. After 6, 12, or 26 weeks, evaluation of the reinsertion site of the infraspinatus tendon was performed. The mechanical load-to-failure and stiffness results did not indicate a significant difference between the two groups. After 26 weeks, fibrocartilage was sparse in the AAMA group, whereas the SMMA group showed the most pronounced amount of fibrocartilage. We found no ultrastructural differences in collagen fiber organization between the two groups. The relative expression of collagen type II mRNA in the normal group was 1.11. For the AAMA group, 6 weeks after surgery, the relative expression was 55.47, whereas for the SMMA group it was 1.90. This in vivo study showed that the AAMA group exhibited a tendon-to-bone healing process more favorable in its cell biology than that of the traditional SMMA technique. Therefore, the AAMA technique might also be more appropriate for arthroscopic repair.

  17. Preservation of bursal-sided tendon in partial-thickness articular-sided rotator cuff tears: a novel arthroscopic transtendon anatomic repair technique.

    Science.gov (United States)

    Shin, Sang-Jin; Jeong, Jae-Hoon; Jeon, Yoon Sang; Kim, Rag Gyu

    2016-12-01

    The purpose of this study was to introduce a novel arthroscopic transtendon anatomic repair technique that spares the intact bursal-sided tendon in articular-sided partial-thickness rotator cuff tears (PTRCT) and to present shoulder functional outcomes in patients with symptomatic articular-sided PCRCT that involves more than 50 % of its thickness after arthroscopic repair using a novel technique. Eighteen patients with symptomatic articular-sided PCRCT involving more than 50 % of the tendon's thickness underwent arthroscopic repair using a devised technique. The devised technique restores only the torn articular portion of the rotator cuff at the anatomical footprint using a suture anchor, and preserves the integrity of the corresponding bursal-sided tendon by tying knots at the most lateral bursal side on the subacromial space. Clinical and functional outcome using ASES and Constant scores were evaluated. The structural integrity of the rotator cuff was evaluated by MRI at 6 months postoperatively. Pain relief and shoulder functional outcomes were encouraging during the recovery phase after operation. ASES (preoperative 54.0 ± 10.3 to postoperative 92.6 ± 8.0), Constant score (61.2 ± 8.5-88.0 ± 5.3), VAS for pain (4.9 ± 2.6-0.6 ± 0.7) improved significantly after arthroscopic transtendon anatomic repair (p rotator cuff retears on 6-month MRI. No complications related to surgical procedures had occurred. The devised technique of arthroscopic transtendon repair provided satisfactory functional outcomes without postoperative discomforts. This technique minimizes over-tightening of the articular layer and reduces tension mismatches between the articular and bursal layers, which are considered as important factors for improvement of postoperative shoulder motion.

  18. A comparison of the techniques of direct pars interarticularis repairs for spondylolysis and low-grade spondylolisthesis: a meta-analysis.

    Science.gov (United States)

    Mohammed, Nasser; Patra, Devi Prasad; Narayan, Vinayak; Savardekar, Amey R; Dossani, Rimal Hanif; Bollam, Papireddy; Bir, Shyamal; Nanda, Anil

    2018-01-01

    OBJECTIVE Spondylosis with or without spondylolisthesis that does not respond to conservative management has an excellent outcome with direct pars interarticularis repair. Direct repair preserves the segmental spinal motion. A number of operative techniques for direct repair are practiced; however, the procedure of choice is not clearly defined. The present study aims to clarify the advantages and disadvantages of the different operative techniques and their outcomes. METHODS A meta-analysis was conducted in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. The following databases were searched: PubMed, Cochrane Library, Web of Science, and CINAHL ( Cumulative Index to Nursing and Allied Health Literature). Studies of patients with spondylolysis with or without low-grade spondylolisthesis who underwent direct repair were included. The patients were divided into 4 groups based on the operative technique used: the Buck repair group, Scott repair group, Morscher repair group, and pedicle screw-based repair group. The pooled data were analyzed using the DerSimonian and Laird random-effects model. Tests for bias and heterogeneity were performed. The I 2 statistic was calculated, and the results were analyzed. Statistical analysis was performed using StatsDirect version 2. RESULTS Forty-six studies consisting of 900 patients were included in the study. The majority of the patients were in their 2nd decade of life. The Buck group included 19 studies with 305 patients; the Scott group had 8 studies with 162 patients. The Morscher method included 5 studies with 193 patients, and the pedicle group included 14 studies with 240 patients. The overall pooled fusion, complication, and outcome rates were calculated. The pooled rates for fusion for the Buck, Scott, Morscher, and pedicle screw groups were 83.53%, 81.57%, 77.72%, and 90.21%, respectively. The pooled complication rates for the Buck, Scott, Morscher, and pedicle

  19. Single incision laparoscopic surgery (SILS) inguinal hernia repair - recent clinical experiences of this novel technique.

    Science.gov (United States)

    Yussra, Y; Sutton, P A; Kosai, N R; Razman, J; Mishra, R K; Harunarashid, H; Das, S

    2013-01-01

    Inguinal hernia remains the most commonly encountered surgical problem. Various methods of repair have been described, and the most suitable one debated. Single port access (SPA) surgery is a rapidly evolving field, and has the advantage of affording 'scarless' surgery. Single incision laparoscopic surgery (SILS) for inguinal hernia repair is seen to be feasible in both total extraperitoneal (TEP) and transabdominal pre-peritoneal (TAPP) approaches. Data and peri-operative information on both of these however are limited. We aimed to review the clinical experience, feasibility and short term complications related to laparoscopic inguinal hernia repair via single port access. A literature search was performed using Google Scholar, Springerlink Library, Highwire Press, Surgical Endoscopy Journal, World Journal of Surgery and Medscape. The following search terms were used: laparoscopic hernia repair, TAPP, TEP, single incision laparoscopic surgery (SILS). Fourteen articles in English language related to SILS inguinal hernia repair were identified. Nine articles were related to TEP repair and the remaining 5 to TAPP. A total of 340 patients were reported within these studies: 294 patients having a TEP repair and 46 a TAPP. Only two cases of recurrence were reported. Various ports have been utilized, including the SILS port, Tri-Port and a custom- made port using conventional laparoscopic instruments. The duration of surgery was 40-100 minutes and the average length of hospital stay was one day. Early outcomes of this novel technique show it to be feasible, safe and with potentially better cosmetic outcome.

  20. An evaluation of meniscal collagenous structure using optical projection tomography

    International Nuclear Information System (INIS)

    Andrews, Stephen HJ; Ronsky, Janet L; Rattner, Jerome B; Shrive, Nigel G; Jamniczky, Heather A

    2013-01-01

    The collagenous structure of menisci is a complex network of circumferentially oriented fascicles and interwoven radially oriented tie-fibres. To date, examination of this micro- architecture has been limited to two-dimensional imaging techniques. The purpose of this study was to evaluate the ability of the three-dimensional imaging technique; optical projection tomography (OPT), to visualize the collagenous structure of the meniscus. If successful, this technique would be the first to visualize the macroscopic orientation of collagen fascicles in 3-D in the meniscus and could further refine load bearing mechanisms in the tissue. OPT is an imaging technique capable of imaging samples on the meso-scale (1-10 mm) at a micro-scale resolution. The technique, similar to computed tomography, takes two-dimensional images of objects from incremental angles around the object and reconstructs them using a back projection algorithm to determine three-dimensional structure. Bovine meniscal samples were imaged from four locations (outer main body, femoral surface, tibial surface and inner main body) to determine the variation in collagen orientation throughout the tissue. Bovine stifles (n = 2) were obtained from a local abattoir and the menisci carefully dissected. Menisci were fixed in methanol and subsequently cut using a custom cutting jig (n = 4 samples per meniscus). Samples were then mounted in agarose, dehydrated in methanol and subsequently cleared using benzyl alcohol benzyl benzoate (BABB) and imaged using OPT. Results indicate circumferential, radial and oblique collagenous orientations at the contact surfaces and in the inner third of the main body of the meniscus. Imaging identified fascicles ranging from 80-420 μm in diameter. Transition zones where fascicles were found to have a woven or braided appearance were also identified. The outer-third of the main body was composed of fascicles oriented predominantly in the circumferential direction. Blood vessels were

  1. Biomechanical comparison of four double-row speed-bridging rotator cuff repair techniques with or without medial or lateral row enhancement.

    Science.gov (United States)

    Pauly, Stephan; Fiebig, David; Kieser, Bettina; Albrecht, Bjoern; Schill, Alexander; Scheibel, Markus

    2011-12-01

    Biomechanical comparison of four different Speed-Bridge configurations with or without medial or lateral row reinforcement. Reinforcement of the knotless Speed-Bridge double-row repair technique with additional medial mattress- or lateral single-stitches was hypothesized to improve biomechanical repair stability at time zero. Controlled laboratory study: In 36 porcine fresh-frozen shoulders, the infraspinatus tendons were dissected and shoulders were randomized to four groups: (1) Speed-Bridge technique with single tendon perforation per anchor (STP); (2) Speed-Bridge technique with double tendon perforation per anchor (DTP); (3) Speed-Bridge technique with medial mattress-stitch reinforcement (MMS); (4) Speed-Bridge technique with lateral single-stitch reinforcement (LSS). All repairs were cyclically loaded from 10-60 N up to 10-200 N (20 N stepwise increase) using a material testing device. Forces at 3 and 5 mm gap formation, mode of failure and maximum load to failure were recorded. The MMS-technique with double tendon perforation showed significantly higher ultimate tensile strength (338.9 ± 90.0 N) than DTP (228.3 ± 99.9 N), LSS (188.9 ± 62.5 N) and STP-technique (122.2 ± 33.8 N). Furthermore, the MMS-technique provided increased maximal force resistance until 3 and 5 mm gap formation (3 mm: 77.8 ± 18.6 N; 5 mm: 113.3 ± 36.1 N) compared with LSS, DTP and STP (P row defect by tendon sawing first, then laterally. No anchor pullout occurred. Double tendon perforation per anchor and additional medial mattress stitches significantly enhance biomechanical construct stability at time zero in this ex vivo model when compared with the all-knotless Speed-Bridge rotator cuff repair.

  2. Joint line tenderness and McMurray tests for the detection of meniscal lesions: what is their real diagnostic value?

    Science.gov (United States)

    Galli, Marco; Ciriello, Vincenzo; Menghi, Amerigo; Aulisa, Angelo G; Rabini, Alessia; Marzetti, Emanuele

    2013-06-01

    To assess the interobserver concordance of the joint line tenderness (JLT) and McMurray tests, and to determine their diagnostic efficiency for the detection of meniscal lesions. Prospective observational study. Orthopedics outpatient clinic, university hospital. Patients (N=60) with suspected nonacute meniscal lesions who underwent knee arthroscopy. Not applicable. Patients were examined by 3 independent observers with graded levels of experience (>10y, 3y, and 4mo of practice). The interobserver concordance was assessed by Cohen-Fleiss κ statistics. Accuracy, negative and positive predictive values for prevalence 10% to 90%, positive (LR+) and negative (LR-) likelihood ratios, and the Bayesian posttest probability with a positive or negative result were also determined. The diagnostic value of the 2 tests combined was assessed by logistic regression. Arthroscopy was used as the reference test. No interobserver concordance was determined for the JLT. The McMurray test showed higher interobserver concordance, which improved when judgments by the less experienced examiner were discarded. The whole series studied by the "best" examiner (experienced orthopedist) provided the following values: (1) JLT: sensitivity, 62.9%; specificity, 50%; LR+, 1.26; LR-, .74; (2) McMurray: sensitivity, 34.3%; specificity, 86.4%; LR+, 2.52; LR-, .76. The combination of the 2 tests did not offer advantages over the McMurray alone. The JLT alone is of little clinical usefulness. A negative McMurray test does not modify the pretest probability of a meniscal lesion, while a positive result has a fair predictive value. Hence, in a patient with a suspected meniscal lesion, a positive McMurray test indicates that arthroscopy should be performed. In case of a negative result, further examinations, including imaging, are needed. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  3. Satisfaction, function and repair integrity after arthroscopic versus mini-open rotator cuff repair.

    Science.gov (United States)

    Barnes, L A Fink; Kim, H M; Caldwell, J-M; Buza, J; Ahmad, C S; Bigliani, L U; Levine, W N

    2017-02-01

    Advances in arthroscopic techniques for rotator cuff repair have made the mini-open approach less popular. However, the mini-open approach remains an important technique for repair for many surgeons. The aims of this study were to compare the integrity of the repair, the function of the shoulder and satisfaction post-operatively using these two techniques in patients aged > 50 years. We identified 22 patients treated with mini-open and 128 patients treated with arthroscopic rotator cuff repair of July 2007 and June 2011. The mean follow-up was two years (1 to 5). Outcome was assessed using the American Shoulder and Elbow Surgeons (ASES) and Simple Shoulder Test (SST) scores, and satisfaction. The integrity of the repair was assessed using ultrasonography. A power analysis ensured sufficient enrolment. There was no statistically significant difference between the age, function, satisfaction, or pain scores (p > 0.05) of the two groups. The integrity of the repair and the mean SST scores were significantly better in the mini-open group (91% of mini-open repairs were intact versus 60% of arthroscopic repairs, p = 0.023; mean SST score 10.9 (standard deviation (sd) 1.3) in the mini-open group; 8.9 (sd 3.5) in arthroscopic group; p = 0.003). The ASES scores were also higher in the mini-open group (mean ASES score 91.0 (sd 10.5) in mini-open group; mean 82.70 (sd 19.8) in the arthroscopic group; p = 0.048). The integrity of the repair and function of the shoulder were better after a mini-open repair than after arthroscopic repair of a rotator cuff tear in these patients. The functional difference did not translate into a difference in satisfaction. Mini-open rotator cuff repair remains a useful technique despite advances in arthroscopy. Cite this article: Bone Joint J 2017;99-B:245-9. ©2017 The British Editorial Society of Bone & Joint Surgery.

  4. A novel technique of rotator cuff repair using spinal needle and suture loop

    Directory of Open Access Journals (Sweden)

    Muzaffar Nasir

    2010-11-01

    Full Text Available Abstract Background We present a simple technique of arthroscopic rotator cuff repair using a spinal needle and suture loop. Methods With the arthroscope laterally, a spinal needle looped with PDS is inserted percutaneously into the shoulder posteriorly and penetrated through the healthy posterior cuff tear margin. Anteriorly, another spinal needle loaded with PDS is inserted percutaneously to engage the healthy tissue at the anterior tear margin. The suture in the anterior needle is then delivered into the suture loop of the posterior needle using a suture retriever. The posterior needle and loop are then pulled out carrying the anterior suture with it. The two limbs of this suture are then retrieved through a cannula for knotting. The same procedure is then repeated for additional suturing. Suture anchors placed over the greater tuberosity are used to complete the repair. Conclusion This is an easy method of rotator cuff repair using simple instruments and lesser time, hence can be employed at centers with less equipment and at reduced cost to the patient.

  5. Optimizing pressurized contact area in rotator cuff repair: the diamondback repair.

    Science.gov (United States)

    Burkhart, Stephen S; Denard, Patrick J; Obopilwe, Elifho; Mazzocca, Augustus D

    2012-02-01

    The purpose of this study was to compare tendon-bone footprint contact area over time under physiologic loads for 4 different rotator cuff repair techniques: single row (SR), triangle double row (DR), chain-link double row (CL), and diamondback double row (DBK). A supraspinatus tear was created in 28 human cadavers. Tears were fixed with 1 of 4 constructs: SR, DR, CL, or DBK. Immediate post-repair measurements of pressurized contact area were taken in neutral rotation and 0° of abduction. After a static tensile load, pressurized contact area was observed over a 160-minute period after repair. Cyclic loading was then performed. The DBK repair had the highest pressurized contact area initially, as well as the highest pressurized contact area and lowest percentage decrease in pressurized contact area after 160 minutes of testing. The DBK repair had significantly larger initial pressurized contact than CL (P = .003) and SR (P = .004) but not DR (P = .06). The DBK technique was the only technique that produced a pressurized contact area that exceeded the native footprint both at initial repair (P = .01) and after 160 minutes of testing (P = .01). DBK had a significantly larger mean pressurized contact area than all the repairs after 160 minutes of testing (P = .01). DBK had a significantly larger post-cyclic loading pressurized contact area than CL (P = .01) and SR (P = .004) but not DR (P = .07). This study showed that a diamondback repair (a modification of the transosseous repair) can significantly increase the rotator cuff pressurized contact area in comparison with other standard rotator cuff repair constructs when there is sufficient tendon mobility to perform a double-row repair without excessive tension on the repair site. The persistent pressurized contact area of a DBK repair may be desirable to enhance healing potential when there is sufficient tendon mobility to perform a double-row repair, particularly for large or massive rotator cuff tears where it is

  6. Three Tesla MRI for the diagnosis of meniscal and anterior cruciate ligament pathology: a comparison to arthroscopic findings

    International Nuclear Information System (INIS)

    Sampson, M.J.; Jackson, M.P.; Moran, C.J.; Moran, R.; Eustace, S.J.; Shine, S.

    2008-01-01

    Aim: To assess the accuracy of 3 T magnetic resonance imaging (MRI) in the evaluation of meniscal and anterior cruciate ligament (ACL) injury. Materials and methods: Sixty-one consecutive patients were identified who were referred for evaluation of suspected intra-articular pathology with a 3 T MRI and who, subsequently, underwent an arthroscopic procedure of the knee were included for the study. Two musculoskeletal radiologists interpreted the images. The sensitivity, specificity, positive predictive value, and negative predictive value were then calculated for the MRI versus the arthroscopic findings as a reference standard. Results: The sensitivity and specificity for the overall detection of meniscal tears in this study was 84 and 93%, respectively. The results for the medial meniscus separately were 91 and 93% and for the lateral 77 and 93%. The evaluation of ACL integrity was 100% sensitive and specific. The meniscal tear type was correctly identified in 75% of cases and its location in 94%. Conclusion: This study demonstrates good results of 3 T MRI in the evaluation of the injured knee. Caution should still be given to the interpretation on MRI of a lateral meniscus tear, and it is suggested that the standard diagnostic criteria of high signal reaching the articular surface on two consecutive image sections be adhered to even at these higher field strengths

  7. Femoral fracture repair using a locking plate technique in an adult captive polar bear (Ursus maritimus).

    Science.gov (United States)

    Zimmerman, Dawn M; Dew, Terry; Douglass, Michael; Perez, Edward

    2010-02-01

    To report successful femoral fracture repair in a polar bear. Case report. Female polar bear (Ursus maritimus) 5 years and approximately 250 kg. A closed, complete, comminuted fracture of the distal midshaft femur was successfully reduced and stabilized using a compression plating technique with 2 specialized human femur plates offering axial, rotational, and bending support, and allowing the bone to share loads with the implant. Postoperative radiographs were obtained at 11.5 weeks, 11 months, and 24 months. Bone healing characterized by marked periosteal reaction was evident at 11 months with extensive remodeling evident at 24 months. No complications were noted. Distal mid shaft femoral fracture was reduced, stabilized, and healed in an adult polar bear with a locking plate technique using 2 plates. Previously, femoral fractures in polar bears were considered irreparable. Use of 2 plates applied with a locking plate technique can result in successful fracture repair despite large body weight and inability to restrict postoperative activity.

  8. Risk factors, diagnosis and non-surgical treatment for meniscal tears

    DEFF Research Database (Denmark)

    Thorlund, Jonas Bloch; Juhl, Carsten Bogh; Ingelsrud, Lina Holm

    2018-01-01

    quantitatively or qualitatively, as appropriate. Strength of evidence was determined according to the Grading of Recommendations Assessment Development and Evaluation framework. Low-quality evidence suggested that overweight (degenerative tears, k=3), male sex (k=4), contact and pivoting sports (k=2...... investigated exercise versus surgery (k=2) or the effect of surgery in addition to exercise (k=5) for degenerative meniscal tears. There was moderate level of evidence for exercise improving self-reported pain (Effect Size (ES)-0.51, 95% CI -1.16 to 0.13) and function (ES -0.06, 95% CI -0.23 to 0...

  9. Comparison of histologic healing and biomechanical characteristics between repair techniques for a delaminated rotator cuff tear in rabbits.

    Science.gov (United States)

    Cheon, Sang-Jin; Kim, Jung-Han; Gwak, Heui-Chul; Kim, Chang-Wan; Kim, Jeon-Kyo; Park, Ji-Hwan

    2017-05-01

    The purpose of this study was to compare histologic healing and biomechanical characteristics between 2 repair techniques (layer by layer, repair of each layer to bone separately; and whole layer, repair of each layer to the bone en masse) for delaminated rotator cuff tear. Rabbits were used as subjects and classified into 2 groups: group A, right side, the layer-by-layer repair group; and group B, left side, the whole-layer repair group. Histologic evaluations were done at 3 weeks (n = 7) and 6 weeks (n = 4) after operation. Biomechanical tests to evaluate the tensile property were done at time 0 (n = 5) and 3 weeks (n = 5) after operation. Histologic healing improved in all groups. A smaller cleft was found between layers in group B compared with the cleft in group A at 3 weeks after operation. At time 0, group A showed a higher yield load and ultimate failure load (67 ± 10.5 N and 80 ± 7.8 N, respectively). However, at 3 weeks after operation, group B showed a higher yield load (48 ± 7.6 N). In the delaminated rotator cuff tear model in the rabbit, the whole-layer repair showed a narrow gap between layers and a higher yield load at 3 weeks after operation. Surgical techniques that unite the cleft in a delaminated tear could improve biomechanical strength after operation. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  10. Arthroscopic repair of anterosuperior rotator cuff tears: in-continuity technique vs. disruption of subscapularis-supraspinatus tear margin: comparison of clinical outcomes and structural integrity between the two techniques.

    Science.gov (United States)

    Kim, Sung-Jae; Jung, Min; Lee, Jae-Hoo; Kim, Chul; Chun, Yong-Min

    2014-12-17

    The purpose of this study was to compare the clinical outcomes and structural integrity after two techniques of arthroscopic anterosuperior rotator cuff repair: in continuity and disruption of the tear margin. This study included fifty-nine patients who underwent arthroscopic repair of an anterosuperior rotator cuff tear that was done either by disrupting the margin between the subscapularis and supraspinatus tears (Group A) or by performing the repair in continuity without disrupting the margin (Group B). Clinical outcomes were assessed on the basis of a visual analog scale (VAS) pain score, subjective shoulder value (SSV), American Shoulder and Elbow Surgeons (ASES) score, University of California at Los Angeles (UCLA) shoulder score, and active range of motion of the shoulder. Subscapularis strength was assessed with use of the modified belly-press test. Magnetic resonance arthrography (MRA) or computed tomographic arthrography (CTA) was performed at six months after surgery to assess the structural integrity of the repair. At the two-year follow-up evaluation, VAS pain scores, SSVs, ASES scores, UCLA shoulder scores, subscapularis strength, and active range of motion improved significantly in both groups compared with preoperatively (p tears of the rotator cuff, the technique of in-continuity repair did not produce better clinical outcomes or structural integrity than the technique involving disruption of the tear margin. If the muscle in an anterosuperior rotator cuff tear is of good quality, it does not appear to matter whether the tear margin between the subscapularis and supraspinatus is preserved or disrupted. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  11. A new technique for repair of a dislocated sternoclavicular joint using a sternal tension cable system.

    Science.gov (United States)

    Janson, Jacques T; Rossouw, Gawie J

    2013-02-01

    An unstable anterior or posterior sternoclavicular joint dislocation can cause severe morbidity with poor shoulder movement and strength. These dislocations need to be repaired, which can be challenging. Many different procedures have been described to obtain a stable joint fixation with varying results. We report a new technique for repairing a sternoclavicular joint dislocation by using a figure-of-eight sternal cable system. This procedure is relatively simple and reproducible to create a stable and functional sternoclavicular joint. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  12. CRUCIATE LIGAMENT RECONSTRUCTION

    Directory of Open Access Journals (Sweden)

    A. V. Korolev

    2016-01-01

    Full Text Available Purpose: To evaluate long-term results of meniscal repair during arthroscopic ACL reconstruction.Materials and methods: 45 patients who underwent meniscal repair during arthroscopic ACL reconstruction between 2007 and 2013 by the same surgeon were included in the study. In total, fifty meniscus were repaired (26 medial and 24 lateral. Procedures included use of one up to four Fast-Fix implants (Smith & Nephew. In five cases both medial and lateral meniscus were repaired. Cincinnati, IKDC and Lysholm scales were used for long-term outcome analysis.Results: 19 male and 26 female patients were included in the study aging from 15 to 59 years (mean age 33,2±1,5. Median time from injury to surgical procedure was zero months (ranging zero to one. Mean time from surgery to scale analysis was 55,9±3 months (ranged 20-102. Median Cincinnati score was 97 (ranged 90-100, with excellent results in 93% of cases (43 patients and good results in 7% (3 patients. Median IKDC score was 90,8 (ranged 86,2-95,4, with excellent outcomes in 51% of cases (23 patients, good in 33% (15 patients and satisfactory in 16% (7 patients. Median Lysholm score was 95 (ranged 90-100, with excellent outcomes in 76% of cases (34 patients and good in 24% (11 patients. Authors identified no statistical differences when comparing survey results in age, sex and time from trauma to surgery.Conclusions: Results of the present study match the data from orthopedic literature that prove meniscal repair as a safe and efficient procedure with good and excellent outcomes. All-inside meniscal repair can be used irrespectively of patients' age and is efficient even in case of delayed procedures.

  13. Development of biodegradable hyper-branched tissue adhesives for the repair of meniscus tears.

    Science.gov (United States)

    Bochyńska, A I; Van Tienen, T G; Hannink, G; Buma, P; Grijpma, D W

    2016-03-01

    Meniscus tears are one of the most commonly occurring injuries of the knee joint. Current meniscus repair techniques are challenging and do not bring fully satisfactory results. Tissue adhesives are a promising alternative, since they are easy to apply and cause minimal tissue trauma. In this study, a series of amphiphilic copolymers based on polyethylene glycol, trimethylene carbonate and citric acid were synthesized and subsequently end-functionalized with hexamethylene diisocyanate to form reactive adhesive materials. The shear adhesive strength of the networks to bovine meniscus tissue measured in a lap-shear adhesion test ranged between 20 and 80 kPa, which was better than for fibrin glue (10 kPa). The elastic modulus of the networks depended on composition and was in the same range as that of human meniscus. Cell compatibility was assessed using Alamar Blue staining after incubation of the bovine meniscus cells with different concentrations of the glues for 7 days. Cell viability was not affected after adding up to 3mg of the adhesive/mL of medium. The proposed materials are suitable candidates to be used as resorbable tissue adhesives for meniscus repair. They have excellent mechanical and adhesive properties that can be adjusted by varying the composition of the copolymers. Meniscal tears often occur and current treatment strategies do not bring fully satisfactory results. Use of biodegradable tissue adhesives would be an interesting option, but currently available adhesives are not suited due to toxicity or poor mechanical properties. Here, we describe the development of novel biodegradable, hyper-branched, adhesive copolymers. These adhesives cure upon contact with water forming flexible networks. Their adhesion to bovine meniscus tissue was significantly better than that of clinically used fibrin glue. The tensile properties of the cured networks were in the same range of values of the human meniscus. When physiologically relevant amounts were added to

  14. Comparison of gait and pathology outcomes of three meniscal procedures for induction of knee osteoarthritis in sheep.

    Science.gov (United States)

    Cake, M A; Read, R A; Corfield, G; Daniel, A; Burkhardt, D; Smith, M M; Little, C B

    2013-01-01

    Meniscectomy (MX) of sheep induces a well-established animal model of human osteoarthritis (OA). This study compared the clinical (lameness) and pathological outcomes of unilateral, complete medial MX vs two less traumatic and more easily performed meniscal destabilisation procedures. Four-year old wethers (n = 6/group) underwent sham operation, cranial pole release (CPR), mid-body transection (MBT) or total MX of the medial meniscus. Joints were assessed for gross pathology (cartilage erosion and osteophytes), histomorphometry, two histopathology scoring methods (modified Mankin-type and Pritzker score), and immunohistology for ADAMTS- and MMP-cleaved neoepitopes, at 12 weeks post-op. Ground reaction forces (GRFs) were determined by force plate in a subset (n = 4/group) at baseline, 2.5, 8, and 12 weeks post-op. Gross pathology scores of operated groups differed significantly from sham animals (P osteophyte formation. Similarly, histopathology scores were significantly elevated vs sham but did not differ between operated groups at P subchondral sclerosis, suggesting some residual biomechanical effect from the destabilised but intact meniscus. Few significant differences were noted between operated groups in force plate analyses, though gait abnormalities appeared to be least in CPR sheep, and most persistent (>12 weeks) in MBT animals. The well-validated ovine MX model and the simpler meniscal destabilisation procedures resulted in broadly similar joint pathology and lameness. Meniscal CPR or MBT, as easier and more clinically relevant procedures, may represent preferred models for the induction of OA and evaluation of potential disease-modifying therapies. Copyright © 2012 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  15. Association of weight change with progression of meniscal intrasubstance degeneration over 48 months. Data from the Osteoarthritis Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Brandao Guimaraes, Julio [University of California, Musculoskeletal and Quantitative Imaging Research Group (MQIR), Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Federal University of Sao Paulo (UNIFESP), Department of Radiology, Sao Paulo (Brazil); DASA Laboratory, Department of Radiology, Sao Paulo (Brazil); Nevitt, Michael C.; McCulloch, Charles E.; Liu, Felix [University of California, Department of Epidemiology and Biostatistics, San Francisco, CA (United States); Schwaiger, Benedikt J.; Gersing, Alexandra S.; Facchetti, Luca; Bucknor, Matthew D.; Chanchek, Nattagan; Joseph, Gabby B.; Link, Thomas M. [University of California, Musculoskeletal and Quantitative Imaging Research Group (MQIR), Department of Radiology and Biomedical Imaging, San Francisco, CA (United States)

    2018-03-15

    To investigate the association of weight change over 48 months with progression of meniscal intrasubstance degeneration (MID). We studied 487 subjects with MID at baseline and after 48 months using 3-T MRI with the same protocol (FSE sequences with and without fat suppression). These participants lost weight (≥3%, n = 141), had moderate weight gain (3-10%, n = 77), substantial weight gain (>10%, n = 15) or maintained stable weight (n = 254). Progression of MID to a meniscal tear was assessed using the WORMS grading system and compared among weight change groups using logistic regression. ANOVA and chi-square tests were used to study the differences in subjects' characteristics. Progression of MID increased from weight loss to substantial weight gain (p < 0.001) and was significantly more likely with both moderate weight gain (odds ratio [OR], 4.9; 95% confidence interval [CI] 2.4-8.9) and substantial weight gain (OR, 9.5; 95% CI 3.2-28.5) compared to stable weight. Results were similar in both menisci for moderate weight gain (medial: OR, 6.8; 95% CI 3.5-11.3; lateral: OR, 2.6; 95% CI 1.1-6.6) and substantial weight gain (medial: OR, 21.0; 95% CI 5.1-80.7; lateral: OR, 9.7; 95% CI 0.95-100.2). Weight gain is associated with an increased likelihood that meniscal intrasubstance degeneration will progress with the risk increasing with greater weight gain. (orig.)

  16. An Anatomic and Biomechanical Comparison of Bankart Repair Configurations.

    Science.gov (United States)

    Judson, Christopher H; Voss, Andreas; Obopilwe, Elifho; Dyrna, Felix; Arciero, Robert A; Shea, Kevin P

    2017-11-01

    Suture anchor repair for anterior shoulder instability can be performed using a number of different repair techniques, but none has been proven superior in terms of anatomic and biomechanical properties. Purpose/Hypothesis: The purpose was to compare the anatomic footprint coverage and biomechanical characteristics of 4 different Bankart repair techniques: (1) single row with simple sutures, (2) single row with horizontal mattress sutures, (3) double row with sutures, and (4) double row with labral tape. The hypotheses were as follows: (1) double-row techniques would improve the footprint coverage and biomechanical properties compared with single-row techniques, (2) horizontal mattress sutures would increase the footprint coverage compared with simple sutures, and (3) repair techniques with labral tape and sutures would not show different biomechanical properties. Controlled laboratory study. Twenty-four fresh-frozen cadaveric specimens were dissected. The native labrum was removed and the footprint marked and measured. Repair for each of the 4 groups was performed, and the uncovered footprint was measured using a 3-dimensional digitizer. The strength of the repair sites was assessed using a servohydraulic testing machine and a digital video system to record load to failure, cyclic displacement, and stiffness. The double-row repair techniques with sutures and labral tape covered 73.4% and 77.0% of the footprint, respectively. These percentages were significantly higher than the footprint coverage achieved by single-row repair techniques using simple sutures (38.1%) and horizontal mattress sutures (32.8%) ( P row and double-row groups or between the simple suture and horizontal mattress suture techniques. Likewise, there was no difference in the biomechanical properties of the double-row repair techniques with sutures versus labral tape. Double-row repair techniques provided better coverage of the native footprint of the labrum but did not provide superior

  17. Trajectory of self-reported pain and function and knee extensor muscle strength in young patients undergoing arthroscopic surgery for meniscal tears: A systematic review and meta-analysis.

    Science.gov (United States)

    Thorlund, Jonas Bloch; Østengaard, Lasse; Cardy, Nathan; Wilson, Fiona; Jørgensen, Claus; Juhl, Carsten Bogh

    2017-08-01

    To investigate the trajectory of patient reported pain and function and knee extensor muscle strength over time in young individuals undergoing arthroscopic meniscal surgery. Systematic review and meta-analysis METHODS: Six databases were searched up to October 13th, 2016. People aged 30 years or younger undergoing surgery for a meniscal tear. and comparator: (1) Self-reported pain and function in patients undergoing meniscal surgery compared to a non-operative control group (2). Knee extensor strength in the leg undergoing surgery compared to a healthy control group or the contra-lateral leg. Methodological quality was assessed using the SIGN 50 guidelines. No studies were found on patient reported pain and function. Six studies, including 137 patients were included in the analysis on knee extensor muscle strength. Knee extensor muscle strength was impaired in the injured leg prior to surgery and was still reduced compared with control data up to 12 months after surgery (SMD: -1.16) (95% CI: -1.83; -0.49). All included studies were assessed to have a high risk of bias. No studies were found comparing the trajectory of self-reported pain and function in patients undergoing arthroscopic surgery compared with non-operative treatments for young patients with meniscal tears. Knee extensor strength seemed to be impaired up to 12 months after surgery in young patients undergoing surgery for meniscal tears. The results of the present study should be interpreted with caution due to a limited number of available studies with high risk of bias including relatively few patients. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  18. Meniscal root entrapment of an osteochondritis dissecans loose body.

    Science.gov (United States)

    Jones, Christopher R; McMonagle, Joseph S; Garrett, William E

    2014-09-01

    Loose bodies are relatively common in the knee. On radiographs they can often be seen in the medial and lateral gutters, intercondylar notch, and the posterior compartment. At times an apparent loose body is not free to move in the knee because it has been covered by synovium and is no longer mobile. It is uncommon for an osteochondral loose body to become incorporated into meniscal tissue. We report a case of an apparent loose body becoming incorporated into the posterior horn and root of the medial meniscus. We are not aware that this condition has been previously reported. Because removing the entire loose body would have destabilized the posterior root of the medial meniscus, it is important to be aware of this potential occurrence.

  19. Handbook of adhesive bonded structural repair

    CERN Document Server

    Wegman, Raymond F

    1992-01-01

    Provides repair methods for adhesive bonded and composite structures; identifies suitable materials and equipment for repairs; describes damage evaluation criteria and techniques, and methods of inspection before and after repair.

  20. Coronal oblique imaging of the knee: Can it increase radiologists' confidence in diagnosing posterior root meniscal tears?

    International Nuclear Information System (INIS)

    Casagranda, B.U.; Leeman, J.; Costello, J.M.; Rafiee, B.; Harner, C.D.

    2013-01-01

    Aim: To investigate the utility of the coronal oblique sequence in the interrogation of posterior root meniscal lesions. Materials and methods: Following international review board approval, 62 consecutive knee arthroscopy cases were referred to the musculoskeletal (MSK) radiologists from the same orthopaedic surgeon for imaging/surgical correlation of the posterior meniscal roots. Of 62 cases, 45 lateral and 46 medial menisci met the inclusion criteria. Imaging evaluation was performed with standard magnetic resonance imaging (MRI) sequences, including a coronal oblique proton density sequence. Two blinded fellowship-trained MSK radiologists independently evaluated the menisci on standard sequences indicating whether a tear was identified and then specifying a confidence score using a scale of 1–3 on each study interpreted. Immediately thereafter, the coronal oblique sequence was evaluated using the same method. Statistics were performed on meniscal lesions involving the posterior horn/root junction or isolated root tears comparing confidence scores. Results: Reader A identified nine posterior horn/root junction tears and 14 isolated root tears. Following the addition of the coronal oblique sequence, confidence scores increased in three of 14 (21.4%) isolated root tears. All three final reads were concordant with arthroscopy. Reader B identified 10 posterior horn/root junction tears and 19 isolated root tears. The confidence score increased in six cases: five of 19 (26.3%) isolated root tears and one of 10 (10%) posterior horn/root junction tears. All six final reads were concordant with arthroscopy. Kappa coefficients indicated near perfect agreement. Conclusion: The coronal oblique sequence increased reader confidence in nearly 24% of the posterior root cases identified in this series

  1. A biomechanical comparison of 2 techniques of footprint reconstruction for rotator cuff repair: the SwiveLock-FiberChain construct versus standard double-row repair.

    Science.gov (United States)

    Burkhart, Stephen S; Adams, Christopher R; Burkhart, Sarah S; Schoolfield, John D

    2009-03-01

    The purpose of this study was to compare the biomechanical fixation parameters of a standard double-row rotator cuff repair with those of a knotless footprint reconstruction using the double-row SwiveLock-FiberChain technique (Arthrex, Naples, FL). Seven matched pairs of human cadaveric shoulders were used for testing (mean age, 48 +/- 10.3 years). A shoulder from each matched pair was randomly selected to receive a standard 4-anchor double-row repair of the supraspinatus tendon, and the contralateral shoulder received a 4-anchor double-row SwiveLock-FiberChain repair. The tendon was cycled from 10 N to 100 N at 1 Hz for 500 cycles, followed by a single-cycle pull to failure at 33 mm/s. Yield load, ultimate load, cyclic displacement, and mode of failure were recorded. Yield load and ultimate load were higher for the SwiveLock-FiberChain repair compared with the standard double-row repair for 6 of the 7 treatment pairs; however, 1 cadaver had a contrary outcome, so the overall mean differences in yield load and ultimate load were not significantly different from 0 by Student t test (P > .15). Furthermore, smaller differences between yield load and ultimate load for the SwiveLock-FiberChain repair in 5 of the 7 treatment pairs showed a self-reinforcing mechanism. Double-row footprint reconstruction with the knotless SwiveLock-FiberChain system in this study had yield loads, ultimate loads, and cyclic displacements that were statistically equivalent to those of standard double-row rotation cuff reconstructions. The SwiveLock-FiberChain system's combination of strength, self-reinforcement, and decreased operating time may offer advantages to the surgeon, particularly when dealing with older patients in whom poor tissue quality and total operative time are important considerations.

  2. A simple novel technique [PUIT] for closure of urethrocutaneous fistula after hypospadias repair: Preliminary results

    Directory of Open Access Journals (Sweden)

    Awad M

    2005-01-01

    Full Text Available Urethrocutaneous fistula is a common complication of urethroplasty for severe hypospadias, even when a microsurgical technique is applied, the closure of the fistula is a challenging problem. We present a simple surgical procedure, posterior urethral incision technique [PUIT] to close the fistula in our department. Between February 2001 and December 2004 we prospectively evaluated 32 patients, 26 patients with initial hypospadias fistulas and 6 with recurrent fistulas who underwent closure of urethrocutaneous fistula after hypospadias repair. The mean age of patients was 5 years, the operation consisted of trimming the fistula edge after mobilization of the skin all-around then a midline posterior urethral incision was done 2 mm above and 2 mm below the fistula opening then re-approximation of the urethral edges using 6/0 vicryl sutures with loop magnification. The timing of fistula repair was between 6 and 13 months after it was formed, all of these were effectively closed except three cases with stricture and fistula. Of these, two were completely relieved after repeated urethral dilatation, three times a week for 2 weeks. The third failed case will need another sitting after 6 months. The posterior midline urethral incision gives a good opportunity for repair without tension with a good cosmetic outcome. This may be done under local anesthesia in adults. The procedure is considered simple rapid and easy to be done for variable fistulas types whatever of its site and the age.

  3. Evaluación de desenlace: trasplante meniscal versus segunda meniscectomía

    OpenAIRE

    Manrique Otero, Diana Marcela; Moncaleano Ruiz, Viviana; Peña Cruz, Nancy Tatiana; Ramírez Trujillo, Paula; Romero Mora, Jaime Alberto

    2016-01-01

    Introducción: El incremento de pacientes sintomáticos de rodilla y la osteoartrosis en jóvenes con limitadas posibilidades terapéuticas después de una meniscectomía, genera la búsqueda de alternativas terapéuticas. A pesar que es poco utilizado en Colombia, el trasplante meniscal es una propuesta para el manejo sintomático. Según cifras norteamericanas, se practican entre 700.000 a 1.500.000 artroscopias de rodilla anualmente, el 50% termina en meniscectomía y de este un 40% persiste...

  4. New Technique of Exposed Glaucoma Drainage Tube Repair: Report of a Case.

    Science.gov (United States)

    Berezina, Tamara L; Fechtner, Robert D; Cohen, Amir; Kim, Eliott E; Chu, David S

    2015-01-01

    We present the case of successful repair of an exposed glaucoma drainage tube by cornea graft fixation with tissue adhesive, and without subsequent coverage by adjacent conjunctiva or donor tissues. Patient with history of keratoglobus with thin cornea and sclera, and phthisical contralateral eye, underwent three unsuccessful corneal grafts followed by Boston type 1 keratoprosthesis in the right eye. Ahmed drainage device with sclera patch graft was implanted to control the intraocular pressure. Two years later the tube eroded through sclera graft and conjunctiva. Repair was performed by covering the tube with a corneal patch graft secured by tissue adhesive after the conjunctiva in this area was dissected away. The cornea graft was left uncovered due to fragility of adjacent conjunctiva. The healing of ocular and graft surfaces was complete prior to the 1 month follow-up. Conjunctival epithelium covered the corneal patch graft. At 12 months follow-up, the graft and the tube remained stable. Our report suggests that corneal patch graft fixation to the sclera by means of tissue adhesive, without closing the conjunctiva, can be considered as an effective alternative surgical approach for managing exposed glaucoma drainage tube, accompanied by adjacent conjunctiva tissue deficiency. How to cite this article: Berezina TL, Fechtner RD, Cohen A, Kim EE, Chu DS. New Technique of Exposed Glaucoma Drainage Tube Repair: Report of a Case. J Curr Glaucoma Pract 2015;9(2):62-64.

  5. New In-Field Composite Repair Techniques for Transmission or Distribution Pipelines

    Science.gov (United States)

    2009-05-18

    In-field repair of a damaged pipeline must be performed safely, efficiently, rapidly and reliably. Reinforcement of damaged pipelines is typically accomplished by welding a repair patch and then recoating the repaired area. The welded full-encircleme...

  6. Short-term outcome after Onstep versus Lichtenstein technique for inguinal hernia repair

    DEFF Research Database (Denmark)

    Andresen, K; Burcharth, J; Fonnes, S

    2015-01-01

    was to investigate if there were differences in early postoperative pain during the first 10 days between the Onstep and the Lichtenstein technique. METHODS: This was a double-blinded, randomized clinical trial conducted in five surgical departments in Denmark, from April 2013 to June 2014. Eligible participants...... for this study were male patients, >18 years, with a primary inguinal hernia. Experimental treatment in this study was the Onstep technique, which was compared with the Lichtenstein repair. Primary outcome was postoperative pain during the first 10 days following surgery. Secondary outcomes included duration...... of surgery, period for return to normal daily activities (days), and recurrence. Randomization was done in blocks and stratified on centers. Participants and study personnel handling questionnaires and analysis were blinded to the allocation. RESULTS: In total, 290 participants were randomized. We found...

  7. Diagnostic accuracy of the Thessaly test, standardised clinical history and other clinical examination tests (Apley's, McMurray's and joint line tenderness) for meniscal tears in comparison with magnetic resonance imaging diagnosis.

    Science.gov (United States)

    Blyth, Mark; Anthony, Iain; Francq, Bernard; Brooksbank, Katriona; Downie, Paul; Powell, Andrew; Jones, Bryn; MacLean, Angus; McConnachie, Alex; Norrie, John

    2015-08-01

    Reliable non-invasive diagnosis of meniscal tears is difficult. Magnetic resonance imaging (MRI) is often used but is expensive and incidental findings are problematic. There are a number of physical examination tests for the diagnosis of meniscal tears that are simple, cheap and non-invasive. To determine the diagnostic accuracy of the Thessaly test and to determine if the Thessaly test (alone or in combination with other physical tests) can obviate the need for further investigation by MRI or arthroscopy for patients with a suspected meniscal tear. Single-centre prospective diagnostic accuracy study. Although the study was performed in a secondary care setting, it was designed to replicate the results that would have been achieved in a primary care setting. Two cohorts of patients were recruited: patients with knee pathology (n = 292) and a control cohort with no knee pathology (n = 75). Sensitivity, specificity and diagnostic accuracy of the Thessaly test in determining the presence of meniscal tears. Participants were assessed by both a primary care clinician and a musculoskeletal clinician. Both clinicians performed the Thessaly test, McMurray's test, Apley's test, joint line tenderness test and took a standardised clinical history from the patient. The Thessaly test had a sensitivity of 0.66, a specificity of 0.39 and a diagnostic accuracy of 54% when utilised by primary care clinicians. This compared with a sensitivity of 0.62, a specificity of 0.55 and diagnostic accuracy of 59% when used by musculoskeletal clinicians. The diagnostics accuracy of the other tests when used by primary care clinicians was 54% for McMurray's test, 53% for Apley's test, 54% for the joint line tenderness test and 55% for clinical history. For primary care clinicians, age and past history of osteoarthritis were both significant predictors of MRI diagnosis of meniscal tears. For musculoskeletal clinicians age and a positive diagnosis of meniscal tears on clinical history

  8. Direct repair of lumbar spondylolysis by Buck′s technique

    Directory of Open Access Journals (Sweden)

    S Rajasekaran

    2011-01-01

    encountered in the perioperative or postoperative period. Conclusions: In carefully selected patients, direct repair of the pars defect by the Buck′s technique of internal fixation and bone grafting was a safe and effective alternative to fusion in younger patients with symptomatic spondylolysis, without associated spondylolisthesis, who failed conservative management.

  9. Repair of Double Head Pectoralis Major Tendon Avulsion into its Native Footprint Using Bi-cortical EndoButtons and Tendon Sliding Technique.

    Science.gov (United States)

    Prabhu, Jagadish; Faqi, Mohammed Khalid; Alkhalifa, Fahad; Tayara, Bader Kamal; Awad, Rashad Khamis

    2017-01-01

    Injuries to the pectoralis major muscle are relatively infrequent. The mechanism of injury is usually an eccentric shortening of the pectoralis major under heavy load, such as when performing a bench press exercise. We report a case that presented to us with a history of sudden pain in the left pectoral region while doing heavy bench press exercise. The patient sustained a type III D pectoralis muscle -tendon avulsion. Surgical repair was done through a bi-cortical tendon sliding technique using two cortical buttons. In this article we describe our modifications to the previously described surgical technique for the pectoralis major tendon repair using the EndoButton and tension - slide technique, aiming to overcome the possible complications.

  10. Prevalence of Discoid Meniscus During Arthroscopy for Isolated Lateral Meniscal Pathology in the Pediatric Population.

    Science.gov (United States)

    Ellis, Henry B; Wise, Kelsey; LaMont, Lauren; Copley, Lawson; Wilson, Philip

    2017-06-01

    Meniscus tears in the young patient are becoming more prevalent. Knowledge of presenting characteristics and morphology can affect treatment decisions. The purpose of this study was to review and evaluate all the isolated lateral meniscus pathology that required arthroscopic treatment in a pediatric sports medicine practice and compare presenting characteristics between those with a discoid meniscus and those with normal meniscal morphology. We performed a retrospective review of all isolated lateral meniscus arthroscopic procedures from 2003 to 2012 in a high-volume pediatric sports practice. Presentation, radiographs, and intraoperative findings were reviewed. The prevalence and clinical findings of a discoid meniscus in this population and among all age groups were compared with those with a meniscus tear occurring in a normal meniscus. Two hundred and sixty-one arthroscopies were performed for symptomatic isolated lateral menisci pathology. Of these, 75% were discoid in nature; the remainder was tears occurring in normal menisci. Ninety-six of 99 patients (97%) with lateral meniscus pathology under the age of 13 had a discoid meniscus and 66% presented with no injury. There was a transition within the population at 14 years of age, with a rise in the incidence of normal meniscal body tears. Even after this transition point, meniscal pathology incidence remained notable; 59% of isolated lateral meniscus pathology in patients between the ages of 14 and 16 years old were a discoid meniscus. Magnetic resonance imaging criteria for discoid meniscus (3 consecutive sagittal cuts or coronal mid-compartment measure) were unreliable after the age of 13 years old. The ratio of complete to incomplete discoids in all age groups was 4 to 3. In conclusion, discoid menisci have a high prevalence in isolated lateral meniscus pathology requiring knee arthroscopy. Clinical presentation, imaging, characteristics, and treatment may be different among different age groups. In the

  11. Four-Strand Core Suture Improves Flexor Tendon Repair Compared to Two-Strand Technique in a Rabbit Model

    Directory of Open Access Journals (Sweden)

    Alice Wichelhaus

    2016-01-01

    Full Text Available Introduction. This study was designed to investigate the influence of the amount of suture material on the formation of peritendinous adhesions of intrasynovial flexor tendon repairs. Materials and Methods. In 14 rabbits, the flexor tendons of the third and the fourth digit of the right hind leg were cut and repaired using a 2- or 4-strand core suture technique. The repaired tendons were harvested after three and eight weeks. The range of motion of the affected toes was measured and the tendons were processed histologically. The distance between the transected tendon ends, the changes in the peritendinous space, and cellular and extracellular inflammatory reaction were quantified by different staining. Results. A 4-strand core suture resulted in significantly less gap formation. The 2-strand core suture showed a tendency to less adhesion formation. Doubling of the intratendinous suture material was accompanied by an initial increase in leukocyte infiltration and showed a greater amount of formation of myofibroblasts. From the third to the eighth week after flexor tendon repair, both the cellular and the extracellular inflammation decreased significantly. Conclusion. A 4-strand core suture repair leads to a significantly better tendon healing process with less diastasis between the sutured tendon ends despite initially pronounced inflammatory response.

  12. The preclinical sheep model of high tibial osteotomy relating basic science to the clinics: standards, techniques and pitfalls.

    Science.gov (United States)

    Pape, Dietrich; Madry, Henning

    2013-01-01

    To develop a preclinical large animal model of high tibial osteotomy to study the effect of axial alignment on the lower extremity on specific issues of the knee joint, such as in articular cartilage repair, development of osteoarthritis and meniscal lesions. Preoperative planning, surgical procedure and postoperative care known from humans were adapted to develop a HTO model in the adult sheep. Thirty-five healthy, skeletally mature, female Merino sheep between 2 and 4 years of age underwent a HTO of their right tibia in a medial open-wedge technique inducing a normal (group 1) and an excessive valgus alignment (group 2) and a closed-wedge technique (group 3) inducing a varus alignment with the aim of elucidating the effect of limb alignment on cartilage repair in vivo. Animals were followed up for 6 months. Solid bone healing and maintenance of correction are most likely if the following surgical principles are respected: (1) medial and longitudinal approach to the proximal tibia; (2) biplanar osteotomy to increase initial rotatory stability regardless of the direction of correction; (3) small, narrow but long implant with locking screws; (4) posterior plate placement to avoid slope changes; (5) use of bicortical screws to account for the brittle bone of the tibial head and to avoid tibial head displacement. Although successful high tibial osteotomy in sheep is complex, the sheep may--because of its similarities with humans--serve as an elegant model to induce axial malalignment in a clinically relevant environment, and osteotomy healing under challenging mechanical conditions.

  13. The use of the Ma-Griffith technique for percutaneous repair of fresh ruptured tendo Achillis.

    Science.gov (United States)

    Klein, W; Lang, D M; Saleh, M

    1991-01-01

    All patients treated for a rupture of the Achilles tendon by the technique of percutaneous repair were identified from a five year period up to 1987. A review of the patients and results of this technique was undertaken using a clinical grading system. Review was conducted between 18 and 81 months following the injury. Of 38 patients followed up, 71% achieved good results and only 8% poor results. The re-rupture rate for this series was 8%. Sural nerve involvement (13%) was found to be a troublesome complication. During the period under study, a modification to the technique was introduced which abolished this complication. We present our results and describe the modification to the technique. The importance of the use of nonabsorbable sutures is emphasized.

  14. Importance of meniscal injury diagnosis and surgical management in dogs during reconstruction of cranial cruciate ligament rupture: A retrospective study

    Directory of Open Access Journals (Sweden)

    Seok-Beom Seo

    2017-09-01

    Conclusion: Finally based on the clinical superiority, it is recommended that meniscal injury should be checked and corrected during RCCL reconstruction for getting better clinical outcomes. [J Adv Vet Anim Res 2017; 4(3.000: 311-318

  15. Anatomic suture anchor versus the Broström technique for anterior talofibular ligament repair: a biomechanical comparison.

    Science.gov (United States)

    Waldrop, Norman E; Wijdicks, Coen A; Jansson, Kyle S; LaPrade, Robert F; Clanton, Thomas O

    2012-11-01

    Despite the popularity of the Broström procedure for secondary repair of chronic lateral ankle instability, there have been no biomechanical studies reporting on the strength of this secondary repair method, whether using suture fixation or suture anchors. The purpose of our study was to perform a biomechanical comparison of the ultimate load to failure and stiffness of the traditional Broström technique using only a suture repair compared with a suture anchor repair of the anterior talofibular ligament (ATFL) at time zero. We believed that fixation strength of the suture anchor repair would be closer to the strength of the native ligament and allow more aggressive rehabilitation. Controlled laboratory study. Twenty-four fresh-frozen cadaveric ankles were randomly divided into 4 groups of 6 specimens. One group was an intact control group, and the other groups consisted of the traditional Broström and 2 suture anchor modifications (suture anchors in talus or fibula) of the Broström procedure. The specimens were loaded to failure to determine the strength and stiffness of each construct. In load-to-failure testing, ultimate failure loads of the Broström (68.2 ± 27.8 N; P = .013), suture anchor fibula (79.2 ± 34.3 N; P = .037), and suture anchor talus (75.3 ± 45.6 N; P = .027) repairs were significantly lower than that of the intact (160.9 ± 72.2 N) ATFL group. Stiffness of the Broström (6.0 ± 2.5 N/mm; P = .02), suture anchor fibula (6.8 N/mm ± 2.7; P = .05), and suture anchor talus (6.6 N/mm ± 4.0; P = .04) repairs were significantly lower than that of the intact (12.4 N/mm ± 4.1 N/mm) ATFL group. The 3 repair groups were not significantly different from each other, but all 3 were substantially lower in strength and stiffness when compared to the intact ATFL. The use of suture anchors to repair the ATFL produces a repair that can withstand loads to failure similar to the suture-only Broström repair. However, all 3 repair groups were much weaker than

  16. Recurrent tricuspid insufficiency: is the surgical repair technique a risk factor?

    Science.gov (United States)

    Kara, Ibrahim; Koksal, Cengiz; Cakalagaoglu, Canturk; Sahin, Muslum; Yanartas, Mehmet; Ay, Yasin; Demir, Serdar

    2013-01-01

    This study compares the medium-term results of De Vega, modified De Vega, and ring annuloplasty techniques for the correction of tricuspid insufficiency and investigates the risk factors for recurrent grades 3 and 4 tricuspid insufficiency after repair. In our clinic, 93 patients with functional tricuspid insufficiency underwent surgical tricuspid repair from May 2007 through October 2010. The study was retrospective, and all the data pertaining to the patients were retrieved from hospital records. Functional capacity, recurrent tricuspid insufficiency, and risk factors aggravating the insufficiency were analyzed for each patient. In the medium term (25.4 ± 10.3 mo), the rates of grades 3 and 4 tricuspid insufficiency in the De Vega, modified De Vega, and ring annuloplasty groups were 31%, 23.1%, and 6.1%, respectively. Logistic regression analysis revealed that chronic obstructive pulmonary disease, left ventricular dysfunction (ejection fraction, tricuspid insufficiency. Medium-term survival was 90.6% for the De Vega group, 96.3% for the modified De Vega group, and 97.1% for the ring annuloplasty group. Ring annuloplasty provided the best relief from recurrent tricuspid insufficiency when compared with DeVega annuloplasty. Modified De Vega annuloplasty might be a suitable alternative to ring annuloplasty when rings are not available.

  17. One and a half ventricle repair in association with tricuspid valve repair according to "peacock tail" technique in patients with Ebstein's malformation and failing right ventricle.

    Science.gov (United States)

    Prifti, Edvin; Baboci, Arben; Esposito, Giampiero; Kajo, Efrosina; Dado, Elona; Vanini, Vittorio

    2014-05-01

    The aim of this study was to evaluate the outcome in a series of patients with Ebstein's anomaly and a failing right ventricle (RV) undergoing tricuspid valve (TV) repair and bidirectional Glenn cavopulmonary anastomosis (BDG). Between January 2006 and September 2013, 11 consecutive patients diagnosed with severe forms of Ebstein's anomaly and a failing RV underwent TV surgery and BDG. The mean age was 16.5 ± 7 years. Most frequently found symptoms were cyanosis, dyspnea, and arrhythmias. The azygos or hemiazygos veins were left open. The TV was repaired using the "peacock tail" technique, which consisted of total detachment of the anterior and posterior leaflets of the TV and rotation in both directions reimplanting them to the true annulus. The mean follow-up was 3.8 ± 2.4 years (range three months to six years). Hospital mortality was 9% (one patient). TV repair was possible in 10 patients. None of the patients had AV block postoperatively. At one year after surgery, the indexed RV and RA diameter were reduced significantly versus the preoperative data (p = 0.003 and p TV area were 1.2 ± 0.42 and 1.6 ± 0.6 (mm/m2), significantly lower than preoperatively (p = 0.001 and p = 0.008, respectively). The mean NYHA functional class, SaO2 , and cardiothoracic ratio were significantly improved. The peacock tail technique for TV repair in combination with BDG in patients with Ebstein's malformation and depressed RV function results in TV preservation, a low incidence of recurrent regurgitation, favorable functional status and RV function, and resolution of cyanosis. © 2014 Wiley Periodicals, Inc.

  18. Single versus double-row repair of the rotator cuff: does double-row repair with improved anatomical and biomechanical characteristics lead to better clinical outcome?

    Science.gov (United States)

    Pauly, Stephan; Gerhardt, Christian; Chen, Jianhai; Scheibel, Markus

    2010-12-01

    Several techniques for arthroscopic repair of rotator cuff defects have been introduced over the past years. Besides established techniques such as single-row repairs, new techniques such as double-row reconstructions have gained increasing interest. The present article therefore provides an overview of the currently available literature on both repair techniques with respect to several anatomical, biomechanical, clinical and structural endpoints. Systematic literature review of biomechanical, clinical and radiographic studies investigating or comparing single- and double-row techniques. These results were evaluated and compared to provide an overview on benefits and drawbacks of the respective repair type. Reconstructions of the tendon-to-bone unit for full-thickness tears in either single- or double-row technique differ with respect to several endpoints. Double-row repair techniques provide more anatomical reconstructions of the footprint and superior initial biomechanical characteristics when compared to single-row repair. With regard to clinical results, no significant differences were found while radiological data suggest a better structural tendon integrity following double-row fixation. Presently published clinical studies cannot emphasize a clearly superior technique at this time. Available biomechanical studies are in favour of double-row repair. Radiographic studies suggest a beneficial effect of double-row reconstruction on structural integrity of the reattached tendon or reduced recurrent defect rates, respectively.

  19. Impingement syndrome of the shoulder following double row suture anchor technique for arthroscopic rotator cuff repair: a case report

    Directory of Open Access Journals (Sweden)

    Rambani Rohit

    2009-06-01

    Full Text Available Abstract Introduction Arthroscopic repair of the rotator cuff is a demanding surgery. Accurate placement of anchors is key to success. Case presentation A 38-year-old woman received arthroscopic repair of her rotator cuff using a double row suture anchor technique. Postoperatively, she developed impingement syndrome which resulted from vertical displacement of a suture anchor once the shoulder was mobilised. The anchor was removed eight weeks following initial surgery and the patient had an uneventful recovery. Conclusion Impingement syndrome following arthroscopic repair of the rotator cuffs using double row suture anchor has not been widely reported. This is the first such case where anchoring has resulted in impingement syndrome.

  20. Innovative repair of subsidence damage

    International Nuclear Information System (INIS)

    Marino, G.G.

    1992-01-01

    In order to improve handling of subsidence damages the Illinois Mine Subsidence Insurance Fund supported the development of novel cost-effective methods of repair. The research in developing the repairs was directed towards the most common and costly damages that had been observed. As a result repair techniques were designed for structurally cracked foundations in the tension zone; structurally cracked foundations in the compression zone; and damaged or undamaged tilted foundations. When appropriate the postulated methods would result in: 1. significant cost savings (over conventional procedures); 2. a structural capacity greater than when the foundation was uncracked; and 3. an aesthetic appeal. All the postulated repair methodologies were laboratory and/or field tested. This paper will summarize the essentials of each technique developed and the test results

  1. Effects of Laparascopic Hernia Repair by PIRS (Percutan Internal Ring Suturing) Technique on Testicular Artery Blood Supply.

    Science.gov (United States)

    Oral, Akgun; Karaca, Leyla; Ahiskalioglu, Ali; Yildiz, Abdullah; Yigiter, Murat; Celikkaya, Mehmet Emin; Chyndolotov, Temirlan; Salman, Ahmet Bedii

    2018-02-02

    Percutaneous internal ring suturing technique (PIRS) is a minimally invasive technique in pediatric inguinal hernia repair. In the present study, a negative effect on testicular blood flow using PIRS technique has been investigated. Forty male patients were included in the study prospectively. Two groups were formed as conventional open surgery (Group I) and PIRS technique (Group II). The resistive index (RI) value of the testicular artery was measured prospectively by using SMI (superb micro-vascular imaging) software with the color doppler ultrasound technique preoperatively and postoperatively at the first month. Inguinal hernia was present on the left in 35% (n = 14) of the patients and on the right in 65% (n = 26) of the patients. There was no statistically significant difference (p = 0.727) between Group I and II with regard to preoperative RI value (0.66 ± 0.07 vs. 0.66 ± 0.45, respectively). Similarly, there was no statistically significant difference (p = 0.220) between Group I and II with regard to the RI values measured at the postoperative first month (0.58 ± 0.04 vs. 0.60 ± 0.04, respectively). Although the postoperative RI values decreased compared to the preoperative values in both groups, this difference was not statistically significant. (p = 0.447 in Group I, and p = 0.175 in Group II for intragroup comparison). Besides PIRS technique has the advantages provided by all other laparoscopic techniques defined for inguinal hernia repair, there is no significant difference between this technique and conventional open surgery with regard to testicular blood flow. It is an innovative candidate technique instead of the open surgery method besides its additional advantages.

  2. Performance of evaluation techniques for planning preventive repair of leakages on BWR vessel stub tubes

    International Nuclear Information System (INIS)

    Prat, J.P.

    1985-01-01

    Stub tubes have been installed on the control rod drive assemblies of the majority of boiling water reactor vessel bottoms. These stub tubes can undergo a slow process of cracking, producing no potential hazard but occasional plant unavailability due to leakage in excess of specification limits. In the case considered here, the development and application of remotely controlled equipment permitting access both from inside and outside the housing, and of crack evolution and location techniques, has made the progressive development, selection and planning of repairs a possibility, thus minimizing the risk of leakages appearing between refuelling outages. The example used here is of a Nuclear Power Plant in which a first leak appeared in 1981. Since that time extensive and progressive laboratory and field development work has been carried out. This paper presents the experience gained with customized, remote-control inspection equipment, and several developed or adapted techniques, as the basis for an in-service repair decision tree, the case in question being that of a BWR plant in which a cracking process, not affecting safety but potentially affecting availability, has given rise to leaks after ten years of operation

  3. Postpartum perineal reapir performed by midwives: A randomised trial comparing two suture techniques for perineal repair leaving the skin unsutured

    DEFF Research Database (Denmark)

    Kindberg, Sara; Misan, Stehouwer; Hvidman, Lone

    2008-01-01

    Postpartum perineal repair performed by midwives: A randomised trial comparing two suture techniques leaving the skin unsutured. Objective      To compare a continuous suture technique to interrupted stitches using inverted knots for postpartum perineal repair of second-degree lacerations...... and episiotomies.   Design          A double blind randomised controlled trial.   Setting          A Danish university hospital with more than 4800 deliveries annually.   Population   400 healthy primiparous women with a vaginal delivery at term.   Method         Randomisation was computer-controlled. Structured...... healing, patient satisfaction, dyspareunia or need for resuturing. The continuous suture technique was significantly faster (15 min. vs. 17 min, p=0.03) and less suture material was used (1 vs. 2 packets, pskin unsutured...

  4. The relationship between chondromalacia patella, medial meniscal tear and medial periarticular bursitis in patients with osteoarthritis

    OpenAIRE

    Resorlu Mustafa; Doner Davut; Karatag Ozan; Toprak Canan Akgun

    2017-01-01

    Abstract Background This study investigated the presence of bursitis in the medial compartment of the knee (pes anserine, semimembranosus-tibial collateral ligament, and medial collateral ligament bursa) in osteoarthritis, chondromalacia patella and medial meniscal tears. Patients and methods Radiological findings of 100 patients undergoing magnetic resonance imaging with a preliminary diagnosis of knee pain were retrospectively evaluated by two radiologists. The first radiologist assessed al...

  5. Development of laser repair technique for cutting impurities in secondary side of a steam generator

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Cheol Jung; Chung, Chin Man; Kim, Min Suk; Jeong, Tae Moon

    1999-12-01

    In this research, the laser repair technique was investigated for the purpose of cutting impurities in secondary side of a steam generator. For this research, a high quality Nd:YAG laser was manufactured and the beam delivery experiments was performed with multimode optical fibers. Also, the small size focusing system was designed and fabricated for remote cutting and the laser cutting experiment was performed. (author)

  6. Comparison of spin echo T1-weighted sequences versus fast spin-echo proton density-weighted sequences for evaluation of meniscal tears at 1.5 T

    International Nuclear Information System (INIS)

    Wolff, Andrew B.; Pesce, Lorenzo L.; Wu, Jim S.; Smart, L.R.; Medvecky, Michael J.; Haims, Andrew H.

    2009-01-01

    At our institution, fast spin-echo (FSE) proton density (PD) imaging is used to evaluate articular cartilage, while conventional spin-echo (CSE) T1-weighted sequences have been traditionally used to characterize meniscal pathology. We sought to determine if FSE PD-weighted sequences are equivalent to CSE T1-weighted sequences in the detection of meniscal tears, obviating the need to perform both sequences. We retrospectively reviewed the records of knee arthroscopies performed by two arthroscopy-focused surgeons from an academic medical center over a 2-year period. The preoperative MRI images were interpreted independently by two fellowship-trained musculoskeletal radiologists who graded the sagittal CSE T1 and FSE PD sequences at different sittings with grades 1-5, where 1 = normal meniscus, 2 = probable normal meniscus, 3 indeterminate, 4 = probable torn meniscus, and 5 = torn meniscus. Each meniscus was divided into an anterior and posterior half, and these halves were graded separately. Operative findings provided the gold standard. Receiver operating characteristic (ROC) analysis was performed to compare the two sequences. There were 131 tears in 504 meniscal halves. Using ROC analysis, the reader 1 area under curve for FSE PD was significantly better than CSE T1 (0.939 vs. 0.902, >95% confidence). For reader 2, the difference met good criteria for statistical non-inferiority but not superiority (0.913 for FSE PD and 0.908 for CSE T1; >95% non-inferiority for difference at most of -0.027). FSE PD-weighted sequences, using our institutional protocol, are not inferior to CSE T1-weighted sequences for the detection of meniscal tears and may be superior. (orig.)

  7. Plan Repair as an Extension of Planning

    NARCIS (Netherlands)

    Van der Krogt, R.P.J.; De Weerdt, M.M.

    2005-01-01

    In dynamic environments, agents have to deal with changing situations. In these cases, repairing a plan is often more efficient than planning from scratch, but existing planning techniques are more advanced than existing plan repair techniques. Therefore, we propose a straightforward method to

  8. Meniscus tear surgery and meniscus replacement

    Science.gov (United States)

    Vaquero, Javier; Forriol, Francisco

    2016-01-01

    Summary Objective the menisci are easily injured and difficult to repair. The aim of this study was to analyze the current state of meniscal surgery aimed at preserving morphology and conserving the biomechanics of the knee to prevent joint degeneration. Methodology a search of the electronic medical literature database Medline was conducted, from http://www.ncbi.nlm.nih.gov/pubmed. The search was not limited by language. Candidate articles were identified by searching for those that included the keywords meniscus, surgery, suture, implant, allograft. The limits were included for clinical research and clinical trials. Basic research was not included. The studies selected were evaluated and classified in three different categories: basic science, reconstruction (suture and meniscectomy) and implants (scaffolds and allograft). Results the consequences of meniscectomy performed at a young age can lead to a joint cartilage degeneration twenty years later. There are few surgical options for the repair of meniscal injuries in order both to preserve the meniscus and to ensure the long term survival of the knee joint, meniscectomy, repair, suturing the tear, or reconstruction, when a meniscal allograft or synthetic substitute is used to replace the meniscus, but the biomechanical properties of the native meniscus are not reproduced entirely by the scaffolds that exist today. Conclusion therapies that successfully repair or replace the meniscus are therefore likely to prevent or delay osteoarthritis progression. PMID:27331034

  9. Hydrogels for precision meniscus tissue engineering: a comprehensive review.

    Science.gov (United States)

    Rey-Rico, Ana; Cucchiarini, Magali; Madry, Henning

    The meniscus plays a pivotal role to preserve the knee joint homeostasis. Lesions to the meniscus are frequent, have a reduced ability to heal, and may induce tibiofemoral osteoarthritis. Current reconstructive therapeutic options mainly focus on the treatment of lesions in the peripheral vascularized region. In contrast, few approaches are capable of stimulating repair of damaged meniscal tissue in the central, avascular portion. Tissue engineering approaches are of high interest to repair or replace damaged meniscus tissue in this area. Hydrogel-based biomaterials are of special interest for meniscus repair as its inner part contains relatively high proportions of proteoglycans which are responsible for the viscoelastic compressive properties and hydration grade. Hydrogels exhibiting high water content and providing a specific three-dimensional (3D) microenvironment may be engineered to precisely resemble this topographical composition of the meniscal tissue. Different polymers of both natural and synthetic origins have been manipulated to produce hydrogels hosting relevant cell populations for meniscus regeneration and provide platforms for meniscus tissue replacement. So far, these compounds have been employed to design controlled delivery systems of bioactive molecules involved in meniscal reparative processes or to host genetically modified cells as a means to enhance meniscus repair. This review describes the most recent advances on the use of hydrogels as platforms for precision meniscus tissue engineering.

  10. Dynamic augmentation restores anterior tibial translation in ACL suture repair: a biomechanical comparison of non-, static and dynamic augmentation techniques.

    Science.gov (United States)

    Hoogeslag, Roy A G; Brouwer, Reinoud W; Huis In 't Veld, Rianne; Stephen, Joanna M; Amis, Andrew A

    2018-02-03

    There is a lack of objective evidence investigating how previous non-augmented ACL suture repair techniques and contemporary augmentation techniques in ACL suture repair restrain anterior tibial translation (ATT) across the arc of flexion, and after cyclic loading of the knee. The purpose of this work was to test the null hypotheses that there would be no statistically significant difference in ATT after non-, static- and dynamic-augmented ACL suture repair, and they will not restore ATT to normal values across the arc of flexion of the knee after cyclic loading. Eleven human cadaveric knees were mounted in a test rig, and knee kinematics from 0° to 90° of flexion were recorded by use of an optical tracking system. Measurements were recorded without load and with 89-N tibial anterior force. The knees were tested in the following states: ACL-intact, ACL-deficient, non-augmented suture repair, static tape augmentation and dynamic augmentation after 10 and 300 loading cycles. Only static tape augmentation and dynamic augmentation restored ATT to values similar to the ACL-intact state directly postoperation, and maintained this after cyclic loading. However, contrary to dynamic augmentation, the ATT after static tape augmentation failed to remain statistically less than for the ACL-deficient state after cyclic loading. Moreover, after cyclic loading, ATT was significantly less with dynamic augmentation when compared to static tape augmentation. In contrast to non-augmented ACL suture repair and static tape augmentation, only dynamic augmentation resulted in restoration of ATT values similar to the ACL-intact knee and decreased ATT values when compared to the ACL-deficient knee immediately post-operation and also after cyclic loading, across the arc of flexion, thus allowing the null hypotheses to be rejected. This may assist healing of the ruptured ACL. Therefore, this study would support further clinical evaluation of dynamic augmentation of ACL repair.

  11. Lichtenstein Mesh Repair (LMR) v/s Modified Bassini's Repair (MBR) + Lichtenstein Mesh Repair of Direct Inguinal Hernias in Rural Population - A Comparative Study.

    Science.gov (United States)

    Patil, Santosh M; Gurujala, Avinash; Kumar, Ashok; Kumar, Kuthadi Sravan; Mithun, Gorre

    2016-02-01

    Lichtenstein's tension free mesh hernioplasty is the commonly done open technique for inguinal hernias. As our hospital is in rural area, majority of patients are labourers, open hernias are commonly done. The present study was done by comparing Lichtenstein Mesh Repair (LMR) v/s Modified Bassini's repair (MBR) + Lichtenstein mesh repair (LMR) of direct Inguinal Hernias to compare the technique of both surgeries and its outcome like postoperative complications and recurrence rate. A comparative randomized study was conducted on patients reporting to MNR hospital, sangareddy with direct inguinal hernias. A total of fifty consecutive patients were included in this study of which, 25 patients were operated by LMR and 25 patients were operated by MBR+LMR and followed up for a period of two years. The outcomes of the both techniques were compared. Study involved 25 each of Lichtenstein's mesh repair (LMR) and modified bassini's repair (MBR) + LMR, over a period of 2 years. The duration of surgery for lichtenstein mesh repair is around 34.56 min compared to LMR+MBR, which is 47.56 min which was statistically significant (p-value is MBR group in POD 1, but not statistically significant (p-value is 0.0949) and from POD 7 the pain was almost similar in both groups. The recurrence rate is 2% for LMR and 0% for MBR+LMR. LMR+MBR was comparatively better than only LMR in all direct inguinal hernias because of low recurrence rate (0%) and low postoperative complications, which showed in our present study.

  12. Novel Repair Technique for Life-Extension of Hydraulic Turbine Components in Hydroelectric Power Stations

    Science.gov (United States)

    Hiramatsu, Yoichi; Ishii, Jun; Funato, Kazuhiro

    A significant number of hydraulic turbines operated in Japan were installed in the first half of the 20th century. Today, aging degradation and flaws are observed in these turbine equipments. So far, Japanese engineers have applied NDI technology of Ultrasonic Testing (UT) to detect the flaws, and after empirical evaluation of the remaining life they decided an adequate moment to replace the equipments. Since the replacement requires a large-scale field site works and high-cost, one of the solutions for life-extension of the equipments is introduction of repair services. We have been working in order to enhance the accuracy of results during the detection of flaws and flaws dimensioning, in particular focusing on the techniques of Tip-echo, TOFD and Phased-Array UT, accompanied by the conventional UT. These NDI methods made possible to recognize the entire image of surface and embedded flaws with complicated geometry. Then, we have developed an evaluation system of these flaws based on the theory of crack propagation, of the logic of crack growth driven by the stress-intensity factor of the crack tip front. The sophisticated evaluation system is constituted by a hand-made software and database of stress-intensity factor. Based on these elemental technologies, we propose a technique of repair welding to provide a life-extension of hydraulic turbine components.

  13. Imaging techniques for the assessment of fracture repair.

    Science.gov (United States)

    Augat, P; Morgan, E F; Lujan, T J; MacGillivray, T J; Cheung, W H

    2014-06-01

    Imaging of a healing fracture provides a non-invasive and often instructive reproduction of the fracture repair progress and the healing status of bone. However, the interpretation of this reproduction is often qualitative and provides only an indirect and surrogate measure of the mechanical stability of the healing fracture. Refinements of the available imaging techniques have been suggested to more accurately determine the healing status of bone. Plain radiographs provide the ability to determine the degree of bridging of the fracture gap and to quantify the amount of periosteal callus formation. Absorptiometric measures including dual X-ray absorptiometry and computed tomography provide quantitative information on the amount and the density of newly formed bone around the site of the fracture. To include the effect of spatial distribution of newly formed bone, finite element models of healing fracture can be employed to estimate its load bearing capacity. Ultrasound technology not only avoids radiation doses to the patients but also provides the ability to additionally measure vascularity in the surrounding soft tissue of the fracture and in the fracture itself. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Evaluation of the functional results after rotator cuff arthroscopic repair with the suture bridge technique

    Directory of Open Access Journals (Sweden)

    Alberto Naoki Miyazaki

    Full Text Available ABSTRACT OBJECTIVE: To evaluate the results of arthroscopic treatment of large and extensive rotator cuff injuries (RCI that involved the supra and infraspinatus muscles using the suture bridge (SB technique. METHODS: Between July 2010 and November 2014, 37 patients with RCI who were treated with SB technique were evaluated. The study included all patients with a minimum follow-up of 12 months who underwent primary surgery of the shoulder. Twenty-four patients were male and 13 were female. The mean age was 60 years (45-75. The dominant side was affected in 32 cases. The most common cause of injury was trauma (18 cases. The mean preoperative motion was 123°, 58°, T11. Through magnetic resonance imaging, 36 fatty degenerations were classified according to Goutallier. Patients underwent rotator cuff repair with SB technique, which consists of using a medial row anchor with two Corkscrew(r fibertape(r or fiberwire(r at the articular margin, associated with lateral fixation without stitch using PushLocks(r or SwiveLocks(r. RESULTS: The mean age was 60 years and mean fatty degeneration was 2.6. The mean range of motion (following the AAOS in the postoperative evaluation was 148° of forward elevation, 55° in lateral rotation and medial rotation in T9. Using the criteria of the University of California at Los Angeles (UCLA, 35 (94% patients had excellent and good results; one (2.7%, fair; and one (2.7%, poor. CONCLUSION: Arthroscopic repair of a large and extensive RCI using SB technique had good and excellent results in 94% of the patients.

  15. Ultrasonic techniques for repair of aircraft structures with bonded composite patches

    Science.gov (United States)

    Smith, S. H.; Senapati, N.; Francini, R. B.

    1994-01-01

    This is a paper on a research and development project to demonstrate a novel ultrasonic process for the field application of boron/epoxy (B/Ep) patches for repair of aircraft structures. The first phase of the project was on process optimization and testing to develop the most practical ultrasonic processing techniques. Accelerated testing and aging behavior of precured B/Ep patches, which were ultrasonically bonded to simulated B-52 wing panel assemblies, were performed by conducting flight-by-flight spectrum loading fatigue tests. The spectrum represented 2340 missions/flights or 30 years of service. The effects of steady-state applied temperature and prior exposure of the B/Ep composite patches were evaluated. Representative experimental results of this phase of the project are presented.

  16. Midwives conducting perineal repair: The Danish Suture Trial

    DEFF Research Database (Denmark)

    Kindberg, Sara

    2007-01-01

    Midwives conducting perineal repair: The Danish Suture Trial.     Background Suture techniques and materials for repair of 2nd degree perineal lacerations and episiotomies have been tested in several clinical trials. Danish midwives and obstetricians have developed a new, simple and time-efficien......Midwives conducting perineal repair: The Danish Suture Trial.     Background Suture techniques and materials for repair of 2nd degree perineal lacerations and episiotomies have been tested in several clinical trials. Danish midwives and obstetricians have developed a new, simple and time...

  17. Ontology Alignment Repair through Modularization and Confidence-Based Heuristics.

    Directory of Open Access Journals (Sweden)

    Emanuel Santos

    Full Text Available Ontology Matching aims at identifying a set of semantic correspondences, called an alignment, between related ontologies. In recent years, there has been a growing interest in efficient and effective matching methods for large ontologies. However, alignments produced for large ontologies are often logically incoherent. It was only recently that the use of repair techniques to improve the coherence of ontology alignments began to be explored. This paper presents a novel modularization technique for ontology alignment repair which extracts fragments of the input ontologies that only contain the necessary classes and relations to resolve all detectable incoherences. The paper presents also an alignment repair algorithm that uses a global repair strategy to minimize both the degree of incoherence and the number of mappings removed from the alignment, while overcoming the scalability problem by employing the proposed modularization technique. Our evaluation shows that our modularization technique produces significantly small fragments of the ontologies and that our repair algorithm produces more complete alignments than other current alignment repair systems, while obtaining an equivalent degree of incoherence. Additionally, we also present a variant of our repair algorithm that makes use of the confidence values of the mappings to improve alignment repair. Our repair algorithm was implemented as part of AgreementMakerLight, a free and open-source ontology matching system.

  18. Ontology Alignment Repair through Modularization and Confidence-Based Heuristics.

    Science.gov (United States)

    Santos, Emanuel; Faria, Daniel; Pesquita, Catia; Couto, Francisco M

    2015-01-01

    Ontology Matching aims at identifying a set of semantic correspondences, called an alignment, between related ontologies. In recent years, there has been a growing interest in efficient and effective matching methods for large ontologies. However, alignments produced for large ontologies are often logically incoherent. It was only recently that the use of repair techniques to improve the coherence of ontology alignments began to be explored. This paper presents a novel modularization technique for ontology alignment repair which extracts fragments of the input ontologies that only contain the necessary classes and relations to resolve all detectable incoherences. The paper presents also an alignment repair algorithm that uses a global repair strategy to minimize both the degree of incoherence and the number of mappings removed from the alignment, while overcoming the scalability problem by employing the proposed modularization technique. Our evaluation shows that our modularization technique produces significantly small fragments of the ontologies and that our repair algorithm produces more complete alignments than other current alignment repair systems, while obtaining an equivalent degree of incoherence. Additionally, we also present a variant of our repair algorithm that makes use of the confidence values of the mappings to improve alignment repair. Our repair algorithm was implemented as part of AgreementMakerLight, a free and open-source ontology matching system.

  19. Aircraft Propeller Hub Repair

    Energy Technology Data Exchange (ETDEWEB)

    Muth, Thomas R [ORNL; Peter, William H [ORNL

    2015-02-13

    The team performed a literature review, conducted residual stress measurements, performed failure analysis, and demonstrated a solid state additive manufacturing repair technique on samples removed from a scrapped propeller hub. The team evaluated multiple options for hub repair that included existing metal buildup technologies that the Federal Aviation Administration (FAA) has already embraced, such as cold spray, high velocity oxy-fuel deposition (HVOF), and plasma spray. In addition the team helped Piedmont Propulsion Systems, LLC (PPS) evaluate three potential solutions that could be deployed at different stages in the life cycle of aluminum alloy hubs, in addition to the conventional spray coating method for repair. For new hubs, a machining practice to prevent fretting with the steel drive shaft was recommended. For hubs that were refurbished with some material remaining above the minimal material condition (MMC), a silver interface applied by an electromagnetic pulse additive manufacturing method was recommended. For hubs that were at or below the MMC, a solid state additive manufacturing technique using ultrasonic welding (UW) of thin layers of 7075 aluminum to the hub interface was recommended. A cladding demonstration using the UW technique achieved mechanical bonding of the layers showing promise as a viable repair method.

  20. A new barbed device for repair of flexor tendons.

    LENUS (Irish Health Repository)

    Hirpara, K M

    2012-02-01

    We split 100 porcine flexor tendons into five groups of 20 tendons for repair. Three groups were repaired using the Pennington modified Kessler technique, the cruciate or the Savage technique, one using one new device per tendon and the other with two new devices per tendon. Half of the tendons received supplemental circumferential Silfverskiold type B cross-stitch. The repairs were loaded to failure and a record made of their bulk, the force required to produce a 3 mm gap, the maximum force applied before failure and the stiffness. When only one device was used repairs were equivalent to the Pennington modified Kessler for all parameters except the force to produce a 3 mm gap when supplemented with a circumferential repair, which was equivalent to the cruciate. When two devices were used the repair strength was equivalent to the cruciate repair, and when the two-device repair was supplemented with a circumferential suture the force to produce a 3 mm gap was equivalent to that of the Savage six-strand technique.

  1. Anterior cruciate ligament repair - past, present and future.

    Science.gov (United States)

    Mahapatra, Piyush; Horriat, Saman; Anand, Bobby S

    2018-06-15

    This article provides a detailed narrative review on the history and current concepts surrounding ligamentous repair techniques in athletic patients. In particular, we will focus on the anterior cruciate ligament (ACL) as a case study in ligament injury and ligamentous repair techniques. PubMed (MEDLINE), EMBASE and Cochrane Library databases for papers relating to primary anterior cruciate ligament reconstruction were searched by all participating authors. All relevant historical papers were included for analysis. Additional searches of the same databases were made for papers relating to biological enhancement of ligament healing. The poor capacity of the ACL to heal is one of the main reasons why the current gold standard surgical treatment for an ACL injury in an athletic patient is ACL reconstruction with autograft from either the hamstrings or patella tendon. It is hypothesised that by preserving and repairing native tissues and negating the need for autograft that primary ACL repair may represent a key step change in the treatment of ACL injuries. The history of primary ACL repair will be discussed and the circumstances that led to the near-abandonment of primary ACL repair techniques will be reviewed. There has been a recent resurgence in interest with regards to primary ACL repair. Improvements in imaging now allow for identification of tear location, with femoral-sided injuries, being more suitable for repair. We will discuss in details strategies for improving the mechanical and biological environment in order to allow primary healing to occur. In particular, we will explain mechanical supplementation such as Internal Brace Ligament Augmentation and Dynamic Intraligamentary Stabilisation techniques. These are novel techniques that aim to protect the primary repair by providing a stabilising construct that connects the femur and the tibia, thus bridging the repair. In addition, biological supplementation is being investigated as an adjunct and we will

  2. Laparoscopic Repair of Inguinal Hernias

    OpenAIRE

    Carter, Jonathan; Duh, Quan-Yang

    2011-01-01

    For patients with recurrent inguinal hernia, or bilateral inguinal hernia, or for women, laparoscopic repair offers significant advantages over open techniques with regard to recurrence risk, pain, and recovery. For unilateral first-time hernias, either laparoscopic or open repair with mesh can offer excellent results. The major drawback of laparoscopy is that the technique requires a significant number of cases to master. For surgeons in group practice, it makes sense to have one surgeon in ...

  3. Sphenoid dysplasia in neurofibromatosis type 1: a new technique for repair.

    Science.gov (United States)

    Concezio, Di Rocco; Amir, Samii; Gianpiero, Tamburrini; Luca, Massimi; Mario, Giordano

    2017-06-01

    Sphenoid bone dysplasia in neurofibromatosis type 1 is characterized by progressive exophthalmos and facial disfiguration secondary to herniation of meningeal and cerebral structures. We describe a technique for reconstruction of the sphenoid defect apt at preventing or correcting the ocular globe dislocation. After placement of spinal cerebrospinal fluid drainage to reduce intracranial pressure, the temporal pole is posteriorly dislocated extradurally. The greater sphenoid wing defect is identified. A titanium mesh covered by lyophilized dura, modeled in a curved fashion, is interposed between the bone defect and the cerebro-meningeal structures with its convex surface over the retracted temporal pole. The particular configuration of the titanium mesh allows a self-maintaining position due to the pressure exerted by the brain over its convex central part with its lateral margins consequently pushed and self-anchored against the medial and lateral walls of the temporal fossa. Screw fixation is not needed. The technique utilized in four cases proved to be reliable at the long-term clinical and neuroradiological controls (6 to 19 years). Sphenoid bone dysplasia in NF1, resulting in proptosis and exophthalmos, is usually progressive. It can be surgically repaired using a curved titanium mesh with the convexity faced to the temporal pole that is in the opposite fashion from all the techniques previously introduced. When utilized early in life, the technique can prevent the occurrence of the orbital and facial disfiguration.

  4. Imaging of cartilage repair procedures

    International Nuclear Information System (INIS)

    Sanghvi, Darshana; Munshi, Mihir; Pardiwala, Dinshaw

    2014-01-01

    The rationale for cartilage repair is to prevent precocious osteoarthritis in untreated focal cartilage injuries in the young and middle-aged population. The gamut of surgical techniques, normal postoperative radiological appearances, and possible complications have been described. An objective method of recording the quality of repair tissue is with the magnetic resonance observation of cartilage repair tissue (MOCART) score. This scoring system evaluates nine parameters that include the extent of defect filling, border zone integration, signal intensity, quality of structure and surface, subchondral bone, subchondral lamina, and records presence or absence of synovitis and adhesions. The five common techniques of cartilage repair currently offered include bone marrow stimulation (microfracture or drilling), mosaicplasty, synthetic resorbable scaffold grafts, osteochondral allograft transplants, and autologous chondrocyte implantation (ACI). Complications of cartilage repair procedures that may be demonstrated on magnetic resonance imaging (MRI) include plug loosening, graft protuberance, graft depression, and collapse in mosaicplasty, graft hypertrophy in ACI, and immune response leading to graft rejection, which is more common with synthetic grafts and cadaveric allografts

  5. A Comparative Biomechanical Analysis of 2 Double-Row, Distal Triceps Tendon Repairs.

    Science.gov (United States)

    Dorweiler, Matthew A; Van Dyke, Rufus O; Siska, Robert C; Boin, Michael A; DiPaola, Mathew J

    2017-05-01

    Triceps tendon ruptures are rare orthopaedic injuries that almost always require surgical repair. This study tests the biomechanical properties of an original anchorless double-row triceps repair against a previously reported knotless double-row repair. The anchorless double-row triceps repair technique will yield similar biomechanical properties when compared with the knotless double-row repair technique. Controlled laboratory study. Eighteen cadaver arms were randomized into 2 groups. One group received the anchorless repair and the other received the knotless anchor repair. A materials testing system (MTS) machine was used to cycle the repaired arms from 0° to 90° with a 2.5-pound weight for 1500 cycles at 0.25 Hz. Real-time displacement of the tendon was measured during cycling using a probe. Load to failure was performed after completion of cyclic loading. The mean displacement with the anchorless technique was 0.77 mm (SD, 0.25 mm) at 0° (full elbow extension) and 0.76 mm (SD, 0.38 mm) at 90° (elbow flexion). The mean displacement with the anchored technique was 0.83 mm (SD, 0.57 mm) at 0° and 1.01 mm (SD, 0.62 mm) at 90°. There was no statistically significant difference for tendon displacement at 0º ( P = .75) or 90º ( P = .31). The mean load to failure with the anchorless technique was 618.9 N (SD, 185.6 N), while it was 560.5 N (SD, 154.1 N) with the anchored technique, again with no statistically significant difference ( P = .28). Our anchorless double-row triceps repair technique yields comparable biomechanical properties to previously described double-row triceps tendon repair techniques, with the added benefit of avoiding the cost of suture anchors. This anchorless double-row triceps tendon repair can be considered as an acceptable alternative to a knotless anchor repair for triceps tendon ruptures.

  6. The use of recombinant DNA techniques to study radiation-induced damage, repair and genetic change in mammalian cells

    International Nuclear Information System (INIS)

    Thacker, J.

    1986-01-01

    A brief introduction is given to appropriate elements of recombinant DNA techniques and applications to problems in radiobiology are reviewed with illustrative detail. Examples are included of studies with both 254 nm ultraviolet light and ionizing radiation and the review progresses from the molecular analysis of DNA damage in vitro through to the nature of consequent cellular responses. The review is dealt with under the following headings: Molecular distribution of DNA damage, The use of DNA-mediated gene transfer to assess damage and repair, The DNA double strand break: use of restriction endonucleases to model radiation damage, Identification and cloning of DNA repair genes, Analysis of radiation-induced genetic change. (UK)

  7. Diagnosing Snapping Sartorius Tendon Secondary to a Meniscal Cyst Using Dynamic Ultrasound Avoids Incorrect Surgical Procedure

    Directory of Open Access Journals (Sweden)

    Vipin Asopa

    2013-01-01

    Full Text Available We describe a case of painful snapping in the medial aspect of the knee of a 40-year-old man, following a knee hyperflexion injury. Dynamic real-time ultrasonography determined that the snapping was due to the distal tendon of sartorius passing over a medial meniscal cyst. The patient subsequently underwent arthroscopic decompression of the cyst instead of an inappropriate hamstring tendon harvest procedure, with complete resolution of symptoms.

  8. A study of everyday repair: informing interaction design

    OpenAIRE

    Maestri, Leah Adriana

    2012-01-01

    Repair is typically seen in design as the restoration of broken objects to their original state. Repair by non-experts, or everyday repair, can often lead to novel forms of repair resulting in the creative repurposing of objects that are often unforeseen by designers. Using a grounded theory approach, this study describes key aspects of repair including: the techniques non-experts employ for repairing their objects; the motivations that prompt acts of repair; and the outcomes that result fr...

  9. Biomechanical comparison of 4 double-row suture-bridging rotator cuff repair techniques using different medial-row configurations.

    Science.gov (United States)

    Pauly, Stephan; Kieser, Bettina; Schill, Alexander; Gerhardt, Christian; Scheibel, Markus

    2010-10-01

    Biomechanical comparison of different suture-bridge configurations of the medial row with respect to initial construct stability (time 0, porcine model). In 40 porcine fresh-frozen shoulders, the infraspinatus tendons were dissected from their insertions. All specimens were operated on by use of the suture-bridge technique, only differing in terms of the medial-row suture-grasping configuration, and randomized into 4 groups: (1) single-mattress (SM) technique, (2) double-mattress (DM) technique, (3) cross-stitch (CS) technique, and (4) double-pulley (DP) technique. Identical suture anchors were used for all specimens (medial: Bio-Corkscrew FT 5.5 [Arthrex, Naples, FL]; lateral: Bio-PushLock 3.5 [Arthrex]). All repairs were cyclically loaded from 10 to 60 N until 10 to 200 N (20-N stepwise increase after 50 cycles each) with a material testing machine. Forces at 3 and 5 mm of gap formation, mode of failure, and maximum load to failure were recorded. The DM technique had the highest ultimate tensile strength (368.6 ± 99.5 N) compared with the DP (248.4 ± 122.7 N), SM (204.3 ± 90 N), and CS (184.9 ± 63.8 N) techniques (P = .004). The DM technique provided maximal force resistance until 3 and 5 mm of gap formation (90.0 ± 18.1 N and 128.0 ± 32.3 N, respectively) compared with the CS (72 ± 8.9 N and 108 ± 20.2 N, respectively), SM (66.0 ± 8.9 N and 90.0 ± 26.9 N, respectively), and DP (62.2 ± 6.2 N and 71 ± 13.2 N, respectively) techniques (P biomechanical construct stability at time 0 in this porcine ex vivo model. This technique increases initial stability and resistance to suture cutting through the rotator cuff tendon after arthroscopic suture-bridge repair. Copyright © 2010 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  10. Current Biomechanical Concepts for Rotator Cuff Repair

    Science.gov (United States)

    2013-01-01

    For the past few decades, the repair of rotator cuff tears has evolved significantly with advances in arthroscopy techniques, suture anchors and instrumentation. From the biomechanical perspective, the focus in arthroscopic repair has been on increasing fixation strength and restoration of the footprint contact characteristics to provide early rehabilitation and improve healing. To accomplish these objectives, various repair strategies and construct configurations have been developed for rotator cuff repair with the understanding that many factors contribute to the structural integrity of the repaired construct. These include repaired rotator cuff tendon-footprint motion, increased tendon-footprint contact area and pressure, and tissue quality of tendon and bone. In addition, the healing response may be compromised by intrinsic factors such as decreased vascularity, hypoxia, and fibrocartilaginous changes or aforementioned extrinsic compression factors. Furthermore, it is well documented that torn rotator cuff muscles have a tendency to atrophy and become subject to fatty infiltration which may affect the longevity of the repair. Despite all the aforementioned factors, initial fixation strength is an essential consideration in optimizing rotator cuff repair. Therefore, numerous biomechanical studies have focused on elucidating the strongest devices, knots, and repair configurations to improve contact characteristics for rotator cuff repair. In this review, the biomechanical concepts behind current rotator cuff repair techniques will be reviewed and discussed. PMID:23730471

  11. MR imaging of cartilage and its repair in the knee - a review

    International Nuclear Information System (INIS)

    Trattnig, S.; Welsch, G.W.; Domayer, S.; Mosher, T.; Eckstein, F.

    2009-01-01

    Chondral injuries are common lesions of the knee joint, and many patients could benefit from cartilage repair. Widespread cartilage repair techniques require sophisticated noninvasive follow-up using MRI. In addition to the precise morphological assessment of this area of cartilage repair, the cartilage's biochemical constitution can be determined using biochemical MRI techniques. The combination of the clinical outcome after cartilage repair together with the morphological and biochemical description of the cartilage repair tissue as well as the surrounding cartilage can lead to an optimal follow-up evaluation. The present article on MR imaging techniques of cartilage repair focuses on morphological description and scoring using techniques from conventional 2D through advanced isotropic 3D MRI sequences. Furthermore the ultrastructure of the repair tissue and the surrounding cartilage is evaluated in-vivo by biochemical T1-delayed gadolinium enhanced MRI of cartilage (dGEMRIC), T2 relaxation, and diffusion-weighted imaging techniques. (orig.)

  12. Anterolateral ligament abnormalities in patients with acute anterior cruciate ligament rupture are associated with lateral meniscal and osseous injuries

    Energy Technology Data Exchange (ETDEWEB)

    Dyck, Pieter van; Smet, Eline de; Gielen, Jan L.; Parizel, Paul M. [Antwerp University Hospital and University of Antwerp, Department of Radiology, Antwerp (Belgium); Clockaerts, Stefan [University College Hospitals, Department of Orthopaedics, London (United Kingdom); Vanhoenacker, Filip M. [Antwerp University Hospital and University of Antwerp, Department of Radiology, Antwerp (Belgium); Ghent University Hospital and University of Ghent, Department of Radiology, Ghent (Belgium); AZ St-Maarten, Department of Radiology, Antwerp (Belgium); Lambrecht, Valerie [Ghent University Hospital and University of Ghent, Department of Radiology, Ghent (Belgium); Wouters, Kristien [Antwerp University Hospital and University of Antwerp, Department of Biostatistics, Antwerp (Belgium)

    2016-10-15

    To determine the frequency of anterolateral ligament (ALL) injury in patients with acute anterior cruciate ligament (ACL) rupture and to analyse its associated injury patterns. Ninety patients with acute ACL rupture for which MRI was obtained within 8 weeks after the initial trauma were retrospectively identified. Two radiologists assessed the status of the ALL on MRI by consensus. The presence or absence of an ALL abnormality was compared with the existence of medial and lateral meniscal tears diagnosed during arthroscopy. Associated collateral ligament and osseous injuries were documented with MRI. Forty-one of 90 knees (46 %) demonstrated ALL abnormalities on MRI. Of 49 knees with intact ALL, 15 (31 %) had a torn lateral meniscus as compared to 25 torn lateral menisci in 41 knees (61 %) with abnormal ALL (p = 0.008). Collateral ligament (p ≤ 0.05) and osseous injuries (p = 0.0037) were more frequent and severe in ALL-injured as compared with ALL-intact knees. ALL injuries are fairly common in patients with acute ACL rupture and are statistically significantly associated with lateral meniscal, collateral ligament and osseous injuries. (orig.)

  13. Regional and depth variability of porcine meniscal mechanical properties through biaxial testing.

    Science.gov (United States)

    Kahlon, A; Hurtig, M B; Gordon, K D

    2015-01-01

    The menisci in the knee joint undergo complex loading in-vivo resulting in a multidirectional stress distribution. Extensive mechanical testing has been conducted to investigate the tissue properties of the knee meniscus, but the testing conditions do not replicate this complex loading regime. Biaxial testing involves loading tissue along two different directions simultaneously, which more accurately simulates physiologic loading conditions. The purpose of this study was to report mechanical properties of meniscal tissue resulting from biaxial testing, while simultaneously investigating regional variations in properties. Ten left, fresh porcine joints were obtained, and the medial and lateral menisci were harvested from each joint (twenty menisci total). Each menisci was divided into an anterior, middle and posterior region; and three slices (femoral, deep and tibial layers) were obtained from each region. Biaxial and constrained uniaxial testing was performed on each specimen, and Young's moduli were calculated from the resulting stress strain curves. Results illustrated significant differences in regional mechanical properties, with the medial anterior (Young's modulus (E)=11.14 ± 1.10 MPa), lateral anterior (E=11.54 ± 1.10 MPa) and lateral posterior (E=9.0 ± 1.2 MPa) regions exhibiting the highest properties compared to the medial central (E=5.0 ± 1.22 MPa), medial posterior (E=4.16 ± 1.13 MPa) and lateral central (E=5.6 ± 1.20 MPa) regions. Differences with depth were also significant on the lateral meniscus, with the femoral (E=12.7 ± 1.22 MPa) and tibial (E=8.6 ± 1.22 MPa) layers exhibiting the highest Young's moduli. This data may form the basis for future modeling of meniscal tissue, or may aid in the design of synthetic replacement alternatives. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Lichtenstein Mesh Repair (LMR) v/s Modified Bassini’s Repair (MBR) + Lichtenstein Mesh Repair of Direct Inguinal Hernias in Rural Population – A Comparative Study

    Science.gov (United States)

    Patil, Santosh M; Kumar, Ashok; Kumar, Kuthadi Sravan; Mithun, Gorre

    2016-01-01

    Introduction Lichtenstein’s tension free mesh hernioplasty is the commonly done open technique for inguinal hernias. As our hospital is in rural area, majority of patients are labourers, open hernias are commonly done. The present study was done by comparing Lichtenstein Mesh Repair (LMR) v/s Modified Bassini’s repair (MBR) + Lichtenstein mesh repair (LMR) of direct Inguinal Hernias to compare the technique of both surgeries and its outcome like postoperative complications and recurrence rate. Materials and Methods A comparative randomized study was conducted on patients reporting to MNR hospital, sangareddy with direct inguinal hernias. A total of fifty consecutive patients were included in this study of which, 25 patients were operated by LMR and 25 patients were operated by MBR+LMR and followed up for a period of two years. The outcomes of the both techniques were compared. Results Study involved 25 each of Lichtenstein’s mesh repair (LMR) and modified bassini’s repair (MBR) + LMR, over a period of 2 years. The duration of surgery for lichtenstein mesh repair is around 34.56 min compared to LMR+MBR, which is 47.56 min which was statistically significant (p-value is MBR group in POD 1, but not statistically significant (p-value is 0.0949) and from POD 7 the pain was almost similar in both groups. The recurrence rate is 2% for LMR and 0% for MBR+LMR. Conclusion LMR+MBR was comparatively better than only LMR in all direct inguinal hernias because of low recurrence rate (0%) and low postoperative complications, which showed in our present study. PMID:27042517

  15. Mini- or Less-open Sublay Operation (MILOS): A New Minimally Invasive Technique for the Extraperitoneal Mesh Repair of Incisional Hernias.

    Science.gov (United States)

    Reinpold, Wolfgang; Schröder, Michael; Berger, Cigdem; Nehls, Jennifer; Schröder, Alexander; Hukauf, Martin; Köckerling, Ferdinand; Bittner, Reinhard

    2018-01-16

    Improvement of ventral hernia repair. Despite the use of mesh and other recent improvements, the currently popular techniques of ventral hernia repair have specific disadvantages and risks. We developed the endoscopically assisted mini- or less-open sublay (MILOS) concept. The operation is performed transhernially via a small incision with light-holding laparoscopic instruments either under direct, or endoscopic visualization. An endoscopic light tube was developed to facilitate this approach (EndotorchTM Wolf Company). Each MILOS operation can be converted to standard total extraperitoneal gas endoscopy once an extraperitoneal space of at least 8 cm has been created. All MILOS operations were prospectively documented in the German Hernia registry with 1 year questionnaire follow-up. Propensity score matching of incisional hernia operations comparing the results of the MILOS operation with the laparoscopic intraperitoneal onlay mesh operation (IPOM) and open sublay repair from other German Hernia registry institutions was performed. Six hundred fifteen MILOS incisional hernia operations were included. Compared with laparoscopic IPOM incisional hernia operation, the MILOS repair is associated with significantly a fewer postoperative surgical complications (P advantages of open sublay and the laparoscopic IPOM repair.ClinicalTrials.gov Identifier NCT03133000.

  16. Open preperitoneal groin hernia repair with mesh

    DEFF Research Database (Denmark)

    Andresen, Kristoffer; Rosenberg, Jacob

    2017-01-01

    Background For the repair of inguinal hernias, several surgical methods have been presented where the purpose is to place a mesh in the preperitoneal plane through an open access. The aim of this systematic review was to describe preperitoneal repairs with emphasis on the technique. Data sources...... A systematic review was conducted and reported according to the PRISMA statement. PubMed, Cochrane library and Embase were searched systematically. Studies were included if they provided clinical data with more than 30 days follow up following repair of an inguinal hernia with an open preperitoneal mesh......-analysis. Open preperitoneal techniques with placement of a mesh through an open approach seem promising compared with the standard anterior techniques. This systematic review provides an overview of these techniques together with a description of surgical methods and clinical outcomes....

  17. Open preperitoneal groin hernia repair with mesh

    DEFF Research Database (Denmark)

    Andresen, Kristoffer; Rosenberg, Jacob

    2017-01-01

    BACKGROUND: For the repair of inguinal hernias, several surgical methods have been presented where the purpose is to place a mesh in the preperitoneal plane through an open access. The aim of this systematic review was to describe preperitoneal repairs with emphasis on the technique. DATA SOURCES......: A systematic review was conducted and reported according to the PRISMA statement. PubMed, Cochrane library and Embase were searched systematically. Studies were included if they provided clinical data with more than 30 days follow up following repair of an inguinal hernia with an open preperitoneal mesh......-analysis. Open preperitoneal techniques with placement of a mesh through an open approach seem promising compared with the standard anterior techniques. This systematic review provides an overview of these techniques together with a description of surgical methods and clinical outcomes....

  18. Factors associated with clinical and structural outcomes after arthroscopic rotator cuff repair with a suture bridge technique in medium, large, and massive tears.

    Science.gov (United States)

    Choi, Sungwook; Kim, Myung Ku; Kim, Gyeong Min; Roh, Young-Ho; Hwang, Im Kyung; Kang, Hyunseong

    2014-11-01

    This study was conducted to evaluate clinical outcomes, maintenance of repair integrity, and retear rate after arthroscopic rotator cuff repair by a suture bridge technique among patients with medium, large, and massive rotator cuff tears. We evaluated 147 patients who had undergone arthroscopic rotator cuff repair. Clinical and functional evaluations were performed with the Constant and University of California-Los Angeles scores. All patients were confirmed to have magnetic resonance imaging evidence of tendon healing at least 12 months postoperatively. The average postoperative time to follow-up magnetic resonance imaging was 23.4 months (range, 12-48 months). A total of 25 (17.0%) retears were observed. All clinical outcome scores were improved significantly at follow-up. Larger intraoperative tear sizes were correlated with higher retear rates. The incidence of retear was also higher in cases in which the preoperative fatty degeneration grade was higher. The incidence of retear increased with age and in the heavy worker group (e.g., farmers, carriers, car mechanics) but was not statistically significant. Arthroscopic rotator cuff repair by a suture bridge technique yields improvements in clinical outcome measures and a relatively high degree of patient satisfaction despite the fact that repair integrity is not maintained in many cases. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  19. Canine stifle stability following cranial cruciate ligament transection and medial meniscal release

    DEFF Research Database (Denmark)

    Vedel, T.; Kristiansen, S.; Jensen, Bente Rona

    stifle stability was evaluated in right pelvic limbs from canine cadavers under three different test situations (intact, CrCL deficient and medial meniscal release (MMR)). Dogs were euthanized for reasons unrelated to the study, owner approval given for research use and institutional ethical approval...... to an intact stifle PTA between 95.5° and 97°. The mean maximal CTS in CrCL deficient stifles was 52.8% of intact marker separation distance, occurring at an average joint angle of 130°, equivalent to an intact PTA of 109°.After MMR, CTS initiated significantly earlier in extension, at a joint angle of 65...... meniscus, but did not cause a significant change in the maximal amount of CTS....

  20. Primary unilateral cleft lip repair

    OpenAIRE

    Adenwalla, H. S.; Narayanan, P. V.

    2009-01-01

    The unilateral cleft lip is a complex deformity. Surgical correction has evolved from a straight repair through triangular and quadrilateral repairs to the Rotation Advancement Technique of Millard. The latter is the technique followed at our centre for all unilateral cleft lip patients. We operate on these at five to six months of age, do not use pre-surgical orthodontics, and follow a protocol to produce a notch-free vermillion. This is easy to follow even for trainees. We also perform clos...

  1. Biomechanical Analysis of an Arthroscopic Broström Ankle Ligament Repair and a Suture Anchor-Augmented Repair.

    Science.gov (United States)

    Giza, Eric; Whitlow, Scott R; Williams, Brady T; Acevedo, Jorge I; Mangone, Peter G; Haytmanek, C Thomas; Curry, Eugene E; Turnbull, Travis Lee; LaPrade, Robert F; Wijdicks, Coen A; Clanton, Thomas O

    2015-07-01

    Secondary surgical repair of ankle ligaments is often indicated in cases of chronic lateral ankle instability. Recently, arthroscopic Broström techniques have been described, but biomechanical information is limited. The purpose of the present study was to analyze the biomechanical properties of an arthroscopic Broström repair and augmented repair with a proximally placed suture anchor. It was hypothesized that the arthroscopic Broström repairs would compare favorably to open techniques and that augmentation would increase the mean repair strength at time zero. Twenty (10 matched pairs) fresh-frozen foot and ankle cadaveric specimens were obtained. After sectioning of the lateral ankle ligaments, an arthroscopic Broström procedure was performed on each ankle using two 3.0-mm suture anchors with #0 braided polyethylene/polyester multifilament sutures. One specimen from each pair was augmented with a 2.9-mm suture anchor placed 3 cm proximal to the inferior tip of the lateral malleolus. Repairs were isolated and positioned in 20 degrees of inversion and 10 degrees of plantarflexion and loaded to failure using a dynamic tensile testing machine. Maximum load (N), stiffness (N/mm), and displacement at maximum load (mm) were recorded. There were no significant differences between standard arthroscopic repairs and the augmented repairs for mean maximum load and stiffness (154.4 ± 60.3 N, 9.8 ± 2.6 N/mm vs 194.2 ± 157.7 N, 10.5 ± 4.7 N/mm, P = .222, P = .685). Repair augmentation did not confer a significantly higher mean strength or stiffness at time zero. Mean strength and stiffness for the arthroscopic Broström repair compared favorably with previous similarly tested open repair and reconstruction methods, validating the clinical feasibility of an arthroscopic repair. However, augmentation with an additional proximal suture anchor did not significantly strengthen the repair. © The Author(s) 2015.

  2. Fabrication of a two-level tumor bone repair biomaterial based on a rapid prototyping technique

    Energy Technology Data Exchange (ETDEWEB)

    Kai He; Yan Yongnian; Zhang Renji; Wang Xiaohong [Key Laboratory for Advanced Materials Processing Technology, Ministry of Education and Center of Organ Manufacturing, Department of Mechanical Engineering, Tsinghua University, Beijing 100084 (China); Wang Xinluan; Madhukar, Kumta Shekhar; Qin Ling [Department of Orthoapedics and Traumatology, The Chinese University of Hong Kong. Shatin, NT (Hong Kong)], E-mail: wangxiaohong@tsinghua.edu.cn, E-mail: kumta@cuhk.edu.hk, E-mail: qin@ort.cuhk.edu.hk

    2009-06-01

    After the removal of the giant cell tumor (GCT) of bone, it is necessary to fill the defects with adequate biomaterials. A new functional bone repair material with both stimulating osteoblast growth and inhibiting osteoclast activity has been developed with phosphorylated chitosan (P-chitosan) and disodium (1 {yields} 4)-2-deoxy-2-sulfoamino-{beta}-D-glucopyranuronan (S-chitosan) as the additives of poly(lactic acid-co-glycolic acid) (PLGA)/calcium phosphate (TCP) scaffolds based on a double-nozzle low-temperature deposition manufacturing technique. A computer-assisted design model was used and the optimal fabrication parameters were determined through the manipulation of a pure PLGA/TCP system. The microscopic structures, water absorbability and mechanical properties of the samples with different P-chitosan and S-chitosan concentrations were characterized correspondingly. The results suggested that this unique composite porous scaffold material is a potential candidate for the repair of large bone defects after a surgical removal of GCT.

  3. The effect of double-row fixation on initial repair strength in rotator cuff repair: a biomechanical study.

    Science.gov (United States)

    Meier, Steven W; Meier, Jeffrey D

    2006-11-01

    The purpose of this study was to compare the initial mechanical strength of 3 rotator cuff repair techniques. A total of 30 fresh-frozen cadaveric shoulders were prepared, and full-thickness supraspinatus tears were created. Specimens were randomized and placed into 3 groups: (1) transosseous suture technique (group I: TOS, n = 10, 6F/4M), (2) single-row suture anchor fixation (group II: SRSA, n = 10, 6F/4M), and (3) double-row suture anchor fixation (group III: DRSA, n = 10, 6F/4M). Each specimen underwent cyclic load testing from 5 N to 180 N at a rate of 33 mm/sec. The test was stopped when complete failure (repair site gap of 10 mm) or a total of 5,000 cycles was attained. Group I (TOS) failed at an average of 75.3 +/- 22.49 cycles, and group II (SRSA) at an average of 798.3 +/- 73.28 cycles; group III (DRSA) had no failures because all samples were stopped when 5,000 cycles had been completed. Fixation strength of the DRSA technique proved to be significantly greater than that of SRSA (P row suture anchor fixation was significantly stronger than was single-row repair. Therefore, double-row fixation may be superior to other techniques in that it provides a substantially stronger repair that could lead to improved biologic healing. A high incidence of incomplete healing occurs in rotator cuff repair. Use of double-row fixation may help the clinician to address some deficiencies in current methods by increasing the strength of the repair, potentially leading to improved healing rates.

  4. Hypospadias repair with the glanular-frenular collar (GFC) technique.

    Science.gov (United States)

    Özbey, Hüseyin; Etker, Şeref

    2017-02-01

    In the normal human penis, the glans wings merge in the midline ventrally, but are separated by the 'septum glandis' in conjunction with the frenulum. The frenulum is also included in the formation of the distal (glanular and subcoronal) urethra, which has a special part known as the 'fossa navicularis'. This has inspired a hypospadias repair technique that simulates the development of the glanular and subcoronal urethra, which can be incorporated into the repair of all cases of hypospadias. A total of 121 patients with varying degrees of hypospadias underwent surgery with the described technique: a Y-V plasty was used to dissect the inner foreskin, in a fashion that allowed for its ventral mobilization as a frenular mucosal collar. After tubularization of the proximal urethra, a partial spongioplasty was performed that extended up to the subcoronal level. The glans wings were approximated only at their outermost convexities, with a couple of subepithelial sutures, leaving a slit for the meatus. The cleft-like area between the split wings of the glans penis was filled with the terminal ends of the spongiosum and the dartos of the mucosal collar, which converged to form a septum and a neo-frenulum (glanular-frenular collar, GFC). The midline skin closure of the ventral collar and the circumferential foreskin closure was completed as usual. At a mean follow-up of 10 months, two patients developed urethral fistula (2%), six had meatal stenosis (5%), and two had glans dehiscence (2%) that resulted in meatal retraction. Overall, patients had a cosmetically satisfying appearance (Figure). Forty-one received secondary circumcision; the parents of 80 (66%) patients were satisfied with the final foreskin appearance obtained with this method. The split wings of the glans penis or so-called ventral cleft between the glans wings that accommodate the frenulum is part of normal anatomy. Hence, in hypospadias surgery, the approximated glans wings should allow for ventral support

  5. A Comparative Biomechanical Analysis of 2 Double-Row, Distal Triceps Tendon Repairs

    OpenAIRE

    Dorweiler, Matthew A.; Van Dyke, Rufus O.; Siska, Robert C.; Boin, Michael A.; DiPaola, Mathew J.

    2017-01-01

    Background: Triceps tendon ruptures are rare orthopaedic injuries that almost always require surgical repair. This study tests the biomechanical properties of an original anchorless double-row triceps repair against a previously reported knotless double-row repair. Hypothesis: The anchorless double-row triceps repair technique will yield similar biomechanical properties when compared with the knotless double-row repair technique. Study Design: Controlled laboratory study. Methods: Eighteen ca...

  6. A history of meniscal surgery: from ancient times to the twenty-first century.

    Science.gov (United States)

    Di Matteo, B; Moran, C J; Tarabella, V; Viganò, A; Tomba, P; Marcacci, M; Verdonk, R

    2016-05-01

    The science and surgery of the meniscus have evolved significantly over time. Surgeons and scientists always enjoy looking forward to novel therapies. However, as part of the ongoing effort at optimizing interventions and outcomes, it may also be useful to reflect on important milestones from the past. The aim of the present manuscript was to explore the history of meniscal surgery across the ages, from ancient times to the twenty-first century. Herein, some of the investigations of the pioneers in orthopaedics are described, to underline how their work has influenced the management of the injured meniscus in modern times. Level of evidence V.

  7. Intralaryngeal thyroarytaenoid lateralisation using the Fast-Fix 360 system: a canine cadaveric study.

    Science.gov (United States)

    Stegen, Ludo; Kitshoff, Adriaan M; Van Goethem, Bart; Vandekerckhove, Peter; de Rooster, Hilde

    2015-01-01

    Laryngeal paralysis is a condition in which failure of arytaenoid abduction results in a reduced rima glottidis cross-sectional area. The most commonly performed surgical techniques rely on unilateral abduction of the arytaenoid, requiring a lateral or ventral surgical approach to the larynx. The aim of the study was to investigate a novel minimally invasive intralaryngeal thyroarytaenoid lateralisation technique, using the Fast-Fix 360 meniscal repair system. Larynges were harvested from large breed canine cadavers. With the aid of Kirschner wires placed between the centre of the vocal process and the centre of an imaginary line between the cranial thyroid fissure and the cricothyroid articulation, the mean insertion angle was calculated. The Fast-Fix 360 delivery needle inserted intralaryngeally (n=10), according to a simplified insertion angle (70°), resulted in thyroid penetration (>2.5 mm from margin) in all patients. The Fast-Fix was applied unilaterally at 70° with the first toggle fired on the lateral aspect of the thyroid cartilage and inside the laryngeal cavity on retraction. The suture was tightened. Preprocedural (61.06±9.21 mm2) and postprocedural (138.37±26.12 mm2) rima glottidis cross-sectional area was significantly different (P<0.0001). The mean percentage increase in rima glottidis cross-sectional area was 125.96 per cent (±16.54 per cent). Intralaryngeal thyroarytaenoid laterlisation using the Fast-Fix 360 meniscal repair system ex vivo increased the rima glottidis cross-sectional area significantly.

  8. MR accuracy and arthroscopic incidence of meniscal radial tears

    Energy Technology Data Exchange (ETDEWEB)

    Magee, Thomas; Shapiro, Marc; Williams, David [Department of Radiology, Neuroimaging Institute, 27 East Hibiscus Blvd., Melbourne, FL 32901 (United States)

    2002-12-01

    A meniscal radial tear is a vertical tear that involves the inner meniscal margin. The tear is most frequent in the middle third of the lateral meniscus and may extend outward in any direction. We report (1) the arthroscopic incidence of radial tears, (2) MR signs that aid in the detection of radial tears and (3) our prospective accuracy in detection of radial tears. Design and patients. Three musculoskeletal radiologists prospectively read 200 consecutive MR examinations of the knee that went on to arthroscopy by one orthopedic surgeon. MR images were assessed for location and MR characteristics of radial tears. MR criteria used for diagnosis of a radial tear were those outlined by Tuckman et al.: truncation, abnormal morphology and/or lack of continuity or absence of the meniscus on one or more MR images. An additional criterion used was abnormal increased signal in that area on fat-saturated proton density or T2-weighted coronal and sagittal images. Prospective MR readings were correlated with the arthroscopic findings.Results. Of the 200 consecutive knee arthroscopies, 28 patients had radial tears reported arthroscopically (14% incidence). MR readings prospectively demonstrated 19 of the 28 radial tears (68% sensitivity) when the criteria for diagnosis of a radial tear were truncation or abnormal morphology of the meniscus. With the use of the additional criterion of increased signal in the area of abnormal morphology on fat-saturated T2-weighted or proton density weighted sequences, the prospective sensitivity was 25 of 28 radial tears (89% sensitivity). There were no radial tears described in MR reports that were not demonstrated on arthroscopy (i.e., there were no false positive MR readings of radial tears in these 200 patients). Radial tears are commonly seen at arthroscopy. There was a 14% incidence in this series of 200 patients who underwent arthroscopy. Prospective detection of radial tears was 68% as compared with arthroscopy when the criteria as

  9. MR accuracy and arthroscopic incidence of meniscal radial tears

    International Nuclear Information System (INIS)

    Magee, Thomas; Shapiro, Marc; Williams, David

    2002-01-01

    A meniscal radial tear is a vertical tear that involves the inner meniscal margin. The tear is most frequent in the middle third of the lateral meniscus and may extend outward in any direction. We report (1) the arthroscopic incidence of radial tears, (2) MR signs that aid in the detection of radial tears and (3) our prospective accuracy in detection of radial tears. Design and patients. Three musculoskeletal radiologists prospectively read 200 consecutive MR examinations of the knee that went on to arthroscopy by one orthopedic surgeon. MR images were assessed for location and MR characteristics of radial tears. MR criteria used for diagnosis of a radial tear were those outlined by Tuckman et al.: truncation, abnormal morphology and/or lack of continuity or absence of the meniscus on one or more MR images. An additional criterion used was abnormal increased signal in that area on fat-saturated proton density or T2-weighted coronal and sagittal images. Prospective MR readings were correlated with the arthroscopic findings.Results. Of the 200 consecutive knee arthroscopies, 28 patients had radial tears reported arthroscopically (14% incidence). MR readings prospectively demonstrated 19 of the 28 radial tears (68% sensitivity) when the criteria for diagnosis of a radial tear were truncation or abnormal morphology of the meniscus. With the use of the additional criterion of increased signal in the area of abnormal morphology on fat-saturated T2-weighted or proton density weighted sequences, the prospective sensitivity was 25 of 28 radial tears (89% sensitivity). There were no radial tears described in MR reports that were not demonstrated on arthroscopy (i.e., there were no false positive MR readings of radial tears in these 200 patients). Radial tears are commonly seen at arthroscopy. There was a 14% incidence in this series of 200 patients who underwent arthroscopy. Prospective detection of radial tears was 68% as compared with arthroscopy when the criteria as

  10. Application of Rapid Prototyping Technique and Intraoperative Navigation System for the Repair and Reconstruction of Orbital Wall Fractures

    Science.gov (United States)

    Cha, Jong Hyun; Lee, Yong Hae; Ruy, Wan Chul; Roe, Young; Moon, Myung Ho

    2016-01-01

    Background Restoring the orbital cavity in large blow out fractures is a challenge for surgeons due to the anatomical complexity. This study evaluated the clinical outcomes and orbital volume after orbital wall fracture repair using a rapid prototyping (RP) technique and intraoperative navigation system. Methods This prospective study was conducted on the medical records and radiology records of 12 patients who had undergone a unilateral blow out fracture reconstruction using a RP technique and an intraoperative navigation system from November 2014 to March 2015. The surgical results were assessed by an ophthalmic examination and a comparison of the preoperative and postoperative orbital volume ratio (OVR) values. Results All patients had a successful treatment outcome without complications. Volumetric analysis revealed a significant decrease in the mean OVR from 1.0952±0.0662 (ranging from 0.9917 to 1.2509) preoperatively to 0.9942±0.0427 (ranging from 0.9394 to 1.0680) postoperatively. Conclusion The application of a RP technique for the repair of orbital wall fractures is a useful tool that may help improve the clinical outcomes by understanding the individual anatomy, determining the operability, and restoring the orbital cavity volume through optimal implant positioning along with an intraoperative navigation system. PMID:28913272

  11. DNA repair

    International Nuclear Information System (INIS)

    Van Zeeland, A.A.

    1984-01-01

    In this chapter a series of DNA repair pathways are discussed which are available to the cell to cope with the problem of DNA damaged by chemical or physical agents. In the case of microorganisms our knowledge about the precise mechanism of each DNA repair pathway and the regulation of it has been improved considerably when mutants deficient in these repair mechanisms became available. In the case of mammalian cells in culture, until recently there were very little repair deficient mutants available, because in almost all mammalian cells in culture at least the diploid number of chromosomes is present. Therefore the frequency of repair deficient mutants in such populations is very low. Nevertheless because replica plating techniques are improving some mutants from Chinese hamsters ovary cells and L5178Y mouse lymphoma cells are now available. In the case of human cells, cultures obtained from patients with certain genetic diseases are available. A number of cells appear to be sensitive to some chemical or physical mutagens. These include cells from patients suffering from xeroderma pigmentosum, Ataxia telangiectasia, Fanconi's anemia, Cockayne's syndrome. However, only in the case of xeroderma pigmentosum cells, has the sensitivity to ultraviolet light been clearly correlated with a deficiency in excision repair of pyrimidine dimers. Furthermore the work with strains obtained from biopsies from man is difficult because these cells generally have low cloning efficiencies and also have a limited lifespan in vitro. It is therefore very important that more repair deficient mutants will become available from established cell lines from human or animal origin

  12. FLEXOR TENDON REPAIR IN THE HAND

    African Journals Online (AJOL)

    Method of Repair. Cases. AGE, SEX ... method is at fault and not the dexterity of the operator or his technique. .... Physio- therapy seldom makes stiff fingers work, but it prevents .... or repaired later by direct suture, graft or transplant. No. of.

  13. Understanding Magnetic Resonance Imaging of Knee Cartilage Repair: A Focus on Clinical Relevance.

    Science.gov (United States)

    Hayashi, Daichi; Li, Xinning; Murakami, Akira M; Roemer, Frank W; Trattnig, Siegfried; Guermazi, Ali

    2017-06-01

    The aims of this review article are (a) to describe the principles of morphologic and compositional magnetic resonance imaging (MRI) techniques relevant for the imaging of knee cartilage repair surgery and their application to longitudinal studies and (b) to illustrate the clinical relevance of pre- and postsurgical MRI with correlation to intraoperative images. First, MRI sequences that can be applied for imaging of cartilage repair tissue in the knee are described, focusing on comparison of 2D and 3D fast spin echo and gradient recalled echo sequences. Imaging features of cartilage repair tissue are then discussed, including conventional (morphologic) MRI and compositional MRI techniques. More specifically, imaging techniques for specific cartilage repair surgery techniques as described above, as well as MRI-based semiquantitative scoring systems for the knee cartilage repair tissue-MR Observation of Cartilage Repair Tissue and Cartilage Repair OA Knee Score-are explained. Then, currently available surgical techniques are reviewed, including marrow stimulation, osteochondral autograft, osteochondral allograft, particulate cartilage allograft, autologous chondrocyte implantation, and others. Finally, ongoing research efforts and future direction of cartilage repair tissue imaging are discussed.

  14. Analysis for a two-dissimilar-component cold standby repairable system with repair priority

    International Nuclear Information System (INIS)

    Leung, Kit Nam Francis; Zhang Yuanlin; Lai, Kin Keung

    2011-01-01

    In this paper, a cold standby repairable system consisting of two dissimilar components and one repairman is studied. Assume that working time distributions and repair time distributions of the two components are both exponential, and Component 1 has repair priority when both components are broken down. After repair, Component 1 follows a geometric process repair while Component 2 obeys a perfect repair. Under these assumptions, using the perfect repair model, the geometric process repair model and the supplementary variable technique, we not only study some important reliability indices, but also consider a replacement policy T, under which the system is replaced when the working age of Component 1 reaches T. Our problem is to determine an optimal policy T* such that the long-run average loss per unit time (i.e. average loss rate) of the system is minimized. The explicit expression for the average loss rate of the system is derived, and the corresponding optimal replacement policy T* can be found numerically. Finally, a numerical example for replacement policy T is given to illustrate some theoretical results and the model's applicability. - Highlights: → A two-dissimilar-component cold standby system with repair priority is formulated. → The successive up/repair times of Component 1 form a decreasing/increasing geometric process. → Not only some reliability indices but also a replacement policy are studied.

  15. Two Ports Laparoscopic Inguinal Hernia Repair in Children

    Directory of Open Access Journals (Sweden)

    Medhat M. Ibrahim

    2015-01-01

    Full Text Available Introduction. Several laparoscopic treatment techniques were designed for improving the outcome over the last decade. The various techniques differ in their approach to the inguinal internal ring, suturing and knotting techniques, number of ports used in the procedures, and mode of dissection of the hernia sac. Patients and Surgical Technique. 90 children were subjected to surgery and they undergone two-port laparoscopic repair of inguinal hernia in children. Technique feasibility in relation to other modalities of repair was the aim of this work. 90 children including 75 males and 15 females underwent surgery. Hernia in 55 cases was right-sided and in 15 left-sided. Two patients had recurrent hernia following open hernia repair. 70 (77.7% cases were suffering unilateral hernia and 20 (22.2% patients had bilateral hernia. Out of the 20 cases 5 cases were diagnosed by laparoscope (25%. The patients’ median age was 18 months. The mean operative time for unilateral repairs was 15 to 20 minutes and bilateral was 21 to 30 minutes. There was no conversion. The complications were as follows: one case was recurrent right inguinal hernia and the second was stitch sinus. Discussion. The results confirm the safety and efficacy of two ports laparoscopic hernia repair in congenital inguinal hernia in relation to other modalities of treatment.

  16. Laparoscopic totally extraperitoneal inguinal hernia repair: lessons learned from 3,100 hernia repairs over 15 years.

    Science.gov (United States)

    Dulucq, Jean-Louis; Wintringer, Pascal; Mahajna, Ahmad

    2009-03-01

    Two revolutions in inguinal hernia repair surgery have occurred during the last two decades. The first was the introduction of tension-free hernia repair by Liechtenstein in 1989 and the second was the application of laparoscopic surgery to the treatment of inguinal hernia in the early 1990s. The purposes of this study were to assess the safety and effectiveness of laparoscopic totally extraperitoneal (TEP) repair and to discuss the technical changes that we faced on the basis of our accumulative experience. Patients who underwent an elective inguinal hernia repair at the Department of Abdominal Surgery at the Institute of Laparoscopic Surgery (ILS), Bordeaux, between June 1990 and May 2005 were enrolled retrospectively in this study. Patient demographic data, operative and postoperative course, and outpatient follow-up were studied. A total of 3,100 hernia repairs were included in the study. The majority of the hernias were repaired by TEP technique; the repair was done by transabdominal preperitoneal (TAPP) repair in only 3%. Eleven percent of the hernias were recurrences after conventional repair. Mean operative time was 17 min in unilateral hernia and 24 min in bilateral hernia. There were 36 hernias (1.2%) that required conversion: 12 hernias were converted to open anterior Liechtenstein and 24 to laparoscopic TAPP technique. The incidence of intraoperative complications was low. Most of the patients were discharged at the second day of the surgery. The overall postoperative morbidity rate was 2.2%. The incidence of recurrence rate was 0.35%. The recurrence rate for the first 200 repairs was 2.5%, but it decreased to 0.47% for the subsequent 1,254 hernia repairs According to our experience, in the hands of experienced laparoscopic surgeons, laparoscopic hernia repair seems to be the favored approach for most types of inguinal hernias. TEP is preferred over TAPP as the peritoneum is not violated and there are fewer intra-abdominal complications.

  17. Extensive and equivalent repair in both radiation-resistant and radiation-sensitive E. coli determined by a DNA-unwinding technique

    International Nuclear Information System (INIS)

    Ahnstroem, G.; George, A.M.; Cramp, W.A.

    1978-01-01

    The extent of strand breakage and repair in irradiated E. coli B/r and Bsub(s-l) was studied using a DNA-unwinding technique in denaturing conditions of weak alkali. Although these two strains showed widely different response to the lethal effects of ionizing radiation, they both had an equal capacity to repair radiation-induced breaks in DNA. Oxygen enhancement ratios for the killing of B/r and Bsub(s-l) were respectively 4 and 2; but after repair in non-nutrient or nutrient post-irradiation conditions, the oxygen enhancement values for the residual strand breaks were always the same for the two strains. The equal abilities of E.coli B/r and E.coli Bsub(s-l) to remove the strand breaks measured by this weak-alkali technqiue has led to the suggestion that some other type of damage to either DNA or another macromolecule may play a major role in determining whether or not the cells survive to proliferate. (author)

  18. Extensive and equivalent repair in both radiation-resistant and radiation-sensitive E. coli determined by a DNA-unwinding technique

    Energy Technology Data Exchange (ETDEWEB)

    Ahnstroem, G [Stockholm Univ. (Sweden); George, A M; Cramp, W A

    1978-10-01

    The extent of strand breakage and repair in irradiated E. coli B/r and Bsub(s-l) was studied using a DNA-unwinding technique in denaturing conditions of weak alkali. Although these two strains showed widely different response to the lethal effects of ionizing radiation, they both had an equal capacity to repair radiation-induced breaks in DNA. Oxygen enhancement ratios for the killing of B/r and Bsub(s-l) were respectively 4 and 2; but after repair in non-nutrient or nutrient post-irradiation conditions, the oxygen enhancement values for the residual strand breaks were always the same for the two strains. The equal abilities of E.coli B/r and E.coli Bsub(s-l) to remove the strand breaks measured by this weak-alkali technqiue has led to the suggestion that some other type of damage to either DNA or another macromolecule may play a major role in determining whether or not the cells survive to proliferate.

  19. The forked flap repair for hypospadias

    Directory of Open Access Journals (Sweden)

    Anil Chadha

    2012-01-01

    Full Text Available Context: Despite the abundance of techniques for the repair of Hypospadias, its problems still persist and a satisfactory design to correct the penile curvature with the formation of neourethra from the native urethral tissue or genital or extragenital tissues, with minimal postoperative complications has yet to evolve. Aim: Persisting with such an endeavor, a new technique for the repair of distal and midpenile hypospadias is described. Materials and Methods: The study has been done in 70 cases over the past 11 years. The "Forked-Flap" repair is a single stage method for the repair of such Hypospadias with chordee. It takes advantage of the rich vascular communication at the corona and capitalizes on the established reliability of the meatal based flip-flap. The repair achieves straightening of the curvature of the penis by complete excision of chordee tissue from the ventral surface of the penis beneath the urethral plate. The urethra is reconstructed using the native plate with forked flap extensions and genital tissue relying on the concept of meatal based flaps. Water proofing by dartos tissue and reinforcement by Nesbit′s prepucial tissue transfer completes the one stage procedure. Statistical Analysis: An analysis of 70 cases of this single stage technique of repair of penile hypospadias with chordee, operated at 3 to 5 years of age over the past 11 years is presented. Results and Conclusion: The Forked Flap gives comparable and replicable results; except for a urethrocutaneous fistula rate of 4% no other complications were observed.

  20. Current Biomechanical Concepts of Suture Bridge Repair Technique for Rotator Cuff Tear

    OpenAIRE

    Ming-Long Yeh; Chih-Kai Hong; Wei-Ren Su; I-Ming Jou; Cheng-Li Lin; Chii-Jen Lin

    2015-01-01

    Rotator cuff tears are one of the most common disorders of the shoulder and can have significant effects on daily activities as a result of pain, loss of motion and strength. The goal of rotator cuff repair is aimed at anatomic restoration of the rotator cuff tendon to reduce pain and improve the joint function. Recently, arthroscopic repair has been widely accepted for treatment of rotator cuff tears due to its equal or better results than those from open repair. In 2006, a...

  1. Flexor tendon repair with a knotless, bidirectional barbed suture: an in vivo biomechanical analysis.

    Science.gov (United States)

    Maddox, Grady E; Ludwig, Jonathan; Craig, Eric R; Woods, David; Joiner, Aaron; Chaudhari, Nilesh; Killingsworth, Cheryl; Siegal, Gene P; Eberhardt, Alan; Ponce, Brent

    2015-05-01

    To compare and analyze biomechanical properties and histological characteristics of flexor tendons either repaired by a 4-strand modified Kessler technique or using barbed suture with a knotless repair technique in an in vivo model. A total of 25 chickens underwent surgical transection of the flexor digitorum profundus tendon followed by either a 4-strand Kessler repair or a knotless repair with barbed suture. Chickens were randomly assigned to 1 of 3 groups with various postoperative times to death. Harvested tendons were subjected to biomechanical testing or histologic analysis. Harvested tendons revealed failures in 25% of knotless repairs (8 of 32) and 8% of 4-strand Kessler repairs (2 of 24). Biomechanical testing revealed no significant difference in tensile strength between 4-strand Kessler and barbed repairs; however, this lack of difference may be attributed to lower statistical power. We noted a trend toward a gradual decrease in strength over time for barbed repairs, whereas we noticed the opposite for the 4-strand Kessler repairs. Mode of failure during testing differed between repair types. The barbed repairs tended toward suture breakage as opposed to 4-strand Kessler repairs, which demonstrated suture pullout. Histological analysis identified no difference in the degree of inflammation or fibrosis; however, there was a vigorous foreign body reaction around the 4-strand Kessler repair and no such response around the barbed repairs. In this model, knotless barbed repairs trended toward higher in vivo failure rates and biomechanical inferiority under physiologic conditions, with each repair technique differing in mode of failure and respective histologic reaction. We are unable to recommend the use of knotless barbed repair over the 4-strand modified Kessler technique. For the repair techniques tested, surgeons should prefer standard Kessler repairs over the described knotless technique with barbed suture. Copyright © 2015 American Society for Surgery

  2. Endovascular Aneurysm Repair Using a Reverse Chimney Technique in a Patient With Marfan Syndrome and Contained Ruptured Chronic Type B Dissection

    International Nuclear Information System (INIS)

    Ketelsen, Dominik; Kalender, Guenay; Heuschmid, Martin; Syha, Roland; Mangold, Stefanie; Claussen, Claus D.; Brechtel, Klaus

    2011-01-01

    We report endovascular thoracic and abdominal aneurysm repair (EVAR) with reverse chimney technique in a patient with contained ruptured type B dissection. EVAR seems feasible as a bailout option in Marfan patients with acute life-threatening disease.

  3. Biomechanical comparison of double-row versus transtendon single-row suture anchor technique for repair of the grade III partial articular-sided rotator cuff tears.

    Science.gov (United States)

    Zhang, Chun-Gang; Zhao, De-Wei; Wang, Wei-Ming; Ren, Ming-Fa; Li, Rui-Xin; Yang, Sheng; Liu, Yu-Peng

    2010-11-01

    For partial-thickness tears of the rotator cuff, double-row fixation and transtendon single-row fixation restore insertion site anatomy, with excellent results. We compared the biomechanical properties of double-row and transtendon single-row suture anchor techniques for repair of grade III partial articular-sided rotator cuff tears. In 10 matched pairs of fresh-frozen sheep shoulders, the infraspinatus tendon from 1 shoulder was repaired with a double-row suture anchor technique. This comprised placement of 2 medial anchors with horizontal mattress sutures at an angle of ≤ 45° into the medial margin of the infraspinatus footprint, just lateral to the articular surface, and 2 lateral anchors with horizontal mattress sutures. Standardized, 50% partial, articular-sided infraspinatus lesions were created in the contralateral shoulder. The infraspinatus tendon from the contralateral shoulder was repaired using two anchors with transtendon single-row mattress sutures. Each specimen underwent cyclic loading from 10 to 100 N for 50 cycles, followed by tensile testing to failure. Gap formation and strain over the footprint area were measured using a motion capture system; stiffness and failure load were determined from testing data. Gap formation for the transtendon single-row repair was significantly smaller (P row repair for the first cycle ((1.74 ± 0.38) mm vs. (2.86 ± 0.46) mm, respectively) and the last cycle ((3.77 ± 0.45) mm vs. (5.89 ± 0.61) mm, respectively). The strain over the footprint area for the transtendon single-row repair was significantly smaller (P row repair. Also, it had a higher mean ultimate tensile load and stiffness. For grade III partial articular-sided rotator cuff tears, transtendon single-row fixation exhibited superior biomechanical properties when compared with double-row fixation.

  4. The contemporary role of 1 vs. 2-stage repair for proximal hypospadias.

    Science.gov (United States)

    Dason, Shawn; Wong, Nathan; Braga, Luis H

    2014-12-01

    This review discusses the most commonly employed techniques in the repair of proximal hypospadias, highlighting the advantages and disadvantages of single versus staged surgical techniques. Hypospadias can have a spectrum of severity with a urethral meatus ranging from the perineum to the glans. Associated abnormalities are commonly found with proximal hypospadias and encompass a large spectrum, including ventral curvature (VC) up to 50 degrees or more, ventral skin deficiency, a flattened glans, penile torsion and penoscrotal transposition. Our contemporary understanding of hypospadiology is comprised of a foundation built by experts who have described a number of techniques and their outcomes, combined with survey data detailing practice patterns. The two largest components of hypospadias repair include repair of VC and urethroplasty. VC greater than 20 degrees is considered clinically relevant to warrant surgical correction. To repair VC, the penis is first degloved-a procedure that may reduce or remove curvature by itself in some cases. Residual curvature is then repaired with dorsal plication techniques, transection of the urethral plate, and/or ventral lengthening techniques. Urethroplasty takes the form of 1- or 2-stage repairs. One-stage options include the tubularized incised urethroplasty (TIP) or various graft or flap-based techniques. Two-stage options also include grafts or flaps, including oral mucosal and preputial skin grafting. One stage repairs are an attractive option in that they may reduce cost, hospital stay, anesthetic risks, and time to the final result. The downside is that these repairs require mastery of multiple techniques may be more complex, and-depending on technique-have higher complication rates. Two-stage repairs are preferred by the majority of surveyed hypospadiologists. The 2-stage repair is versatile and has satisfactory outcomes, but necessitates a second procedure. Given the lack of clear high-quality evidence supporting the

  5. Does strand configuration and number of purchase points affect the biomechanical behavior of a tendon repair? A biomechanical evaluation using different kessler methods of flexor tendon repair.

    Science.gov (United States)

    Dogramaci, Yunus; Kalaci, Aydiner; Sevinç, Teoman Toni; Esen, Erdinc; Komurcu, Mahmut; Yanat, Ahmet Nedim

    2008-09-01

    This study compares the mechanical properties of modified Kessler and double-modified Kessler flexor tendon repair techniques and evaluates simple modifications on both methods. Forty fresh sheep flexor tendons were divided equally into four groups. A transverse sharp cut was done in the middle of each tendon and then repaired with modified Kessler technique, modified Kessler with additional purchase point in the midpoint of each longitudinal strand, double-modified Kessler technique, or a combination of outer Kessler and inner cruciate configuration based on double-modified Kessler technique. The tendons were tested in a tensile testing machine to assess the mechanical performance of the repairs. Outcome measures included gap formation and ultimate forces. The gap strengths of the double-modified Kessler technique (30.85 N, SD 1.90) and double-modified Kessler technique with inner cruciate configuration (33.60 N, SD 4.64) were statistically significantly greater than that of the two-strand modified Kessler (22.56 N, SD 3.44) and modified Kessler with additional purchase configuration (21.75 N, SD 4.03; Tukey honestly significant difference test, P purchase point in modified Kessler repair or changing the inner strand configuration in double-modified Kessler repair. The results of this study show that the number of strands across the repair site together with the number of locking loops clearly affects the strength of the repair; meanwhile, the longitudinal strand orientation and number of purchase points in a single loop did not affect its strength.

  6. JAG Tearing Technique with Radiofrequency Guide Wire for Aortic Fenestration in Thoracic Endovascular Aneurysm Repair

    International Nuclear Information System (INIS)

    Ricci, Carmelo; Ceccherini, Claudio; Leonini, Sara; Cini, Marco; Vigni, Francesco; Neri, Eugenio; Tucci, Enrico; Benvenuti, Antonio; Tommasino, Giulio; Sassi, Carlo

    2012-01-01

    An innovative approach, the JAG tearing technique, was performed during thoracic endovascular aneurysm repair in a patient with previous surgical replacement of the ascending aorta with a residual uncomplicated type B aortic dissection who developed an aneurysm of the descending thoracic aorta with its lumen divided in two parts by an intimal flap. The proximal landing zone was suitable to place a thoracic stent graft. The distal landing zone was created by cutting the intimal flap in the distal third of the descending thoracic aorta with a radiofrequency guide wire and intravascular ultrasound catheter.

  7. Sequelae of Endoscopic Inguinal Hernia Repair : Incidence, evaluation and management

    NARCIS (Netherlands)

    Burgmans, J.P.J.

    2015-01-01

    The endoscopic preperitoneal technique (TEP) is an appealing inguinal hernia repair technique, theoretically superior to other approaches. In practice some problems remain unsolved. Real incidences of chronic postoperative inguinal pain (CPIP) and other important sequelae of endoscopic hernia repair

  8. Surgical repair of large cyclodialysis clefts.

    Science.gov (United States)

    Gross, Jacob B; Davis, Garvin H; Bell, Nicholas P; Feldman, Robert M; Blieden, Lauren S

    2017-05-11

    To describe a new surgical technique to effectively close large (>180 degrees) cyclodialysis clefts. Our method involves the use of procedures commonly associated with repair of retinal detachment and complex cataract extraction: phacoemulsification with placement of a capsular tension ring followed by pars plana vitrectomy and gas tamponade with light cryotherapy. We also used anterior segment optical coherence tomography (OCT) as a noninvasive mechanism to determine the extent of the clefts and compared those results with ultrasound biomicroscopy (UBM) and gonioscopy. This technique was used to repair large cyclodialysis clefts in 4 eyes. All 4 eyes had resolution of hypotony and improvement of visual acuity. One patient had an intraocular pressure spike requiring further surgical intervention. Anterior segment OCT imaging in all 4 patients showed a more extensive cleft than UBM or gonioscopy. This technique is effective in repairing large cyclodialysis clefts. Anterior segment OCT more accurately predicted the extent of each cleft, while UBM and gonioscopy both underestimated the size of the cleft.

  9. Double-row vs single-row rotator cuff repair: a review of the biomechanical evidence.

    Science.gov (United States)

    Wall, Lindley B; Keener, Jay D; Brophy, Robert H

    2009-01-01

    A review of the current literature will show a difference between the biomechanical properties of double-row and single-row rotator cuff repairs. Rotator cuff tears commonly necessitate surgical repair; however, the optimal technique for repair continues to be investigated. Recently, double-row repairs have been considered an alternative to single-row repair, allowing a greater coverage area for healing and a possibly stronger repair. We reviewed the literature of all biomechanical studies comparing double-row vs single-row repair techniques. Inclusion criteria included studies using cadaveric, animal, or human models that directly compared double-row vs single-row repair techniques, written in the English language, and published in peer reviewed journals. Identified articles were reviewed to provide a comprehensive conclusion of the biomechanical strength and integrity of the repair techniques. Fifteen studies were identified and reviewed. Nine studies showed a statistically significant advantage to a double-row repair with regards to biomechanical strength, failure, and gap formation. Three studies produced results that did not show any statistical advantage. Five studies that directly compared footprint reconstruction all demonstrated that the double-row repair was superior to a single-row repair in restoring anatomy. The current literature reveals that the biomechanical properties of a double-row rotator cuff repair are superior to a single-row repair. Basic Science Study, SRH = Single vs. Double Row RCR.

  10. Application of computer-aided three-dimensional skull model with rapid prototyping technique in repair of zygomatico-orbito-maxillary complex fracture.

    Science.gov (United States)

    Li, Wei Zhong; Zhang, Mei Chao; Li, Shao Ping; Zhang, Lei Tao; Huang, Yu

    2009-06-01

    With the advent of CAD/CAM and rapid prototyping (RP), a technical revolution in oral and maxillofacial trauma was promoted to benefit treatment, repair of maxillofacial fractures and reconstruction of maxillofacial defects. For a patient with zygomatico-facial collapse deformity resulting from a zygomatico-orbito-maxillary complex (ZOMC) fracture, CT scan data were processed by using Mimics 10.0 for three-dimensional (3D) reconstruction. The reduction design was aided by 3D virtual imaging and the 3D skull model was reproduced using the RP technique. In line with the design by Mimics, presurgery was performed on the 3D skull model and the semi-coronal incision was taken for reduction of ZOMC fracture, based on the outcome from the presurgery. Postoperative CT and images revealed significantly modified zygomatic collapse and zygomatic arch rise and well-modified facial symmetry. The CAD/CAM and RP technique is a relatively useful tool that can assist surgeons with reconstruction of the maxillofacial skeleton, especially in repairs of ZOMC fracture.

  11. A cell-free scaffold-based cartilage repair provides improved function hyaline-like repair at one year.

    Science.gov (United States)

    Siclari, Alberto; Mascaro, Gennaro; Gentili, Chiara; Cancedda, Ranieri; Boux, Eugenio

    2012-03-01

    Bone marrow stimulation techniques in cartilage repair such as drilling are limited by the formation of fibrous to hyaline-like repair tissue. It has been suggested such techniques can be enhanced by covering the defect with scaffolds. We present an innovative approach using a polyglycolic acid (PGA)-hyaluronan scaffold with platelet-rich-plasma (PRP) in drilling. We asked whether (1) PRP immersed in a cell-free PGA-hyaluronan scaffold improves patient-reported 1-year outcomes for the Knee injury and Osteoarthritis Score (KOOS), and (2) implantation of the scaffold in combination with bone marrow stimulation leads to the formation of hyaline-like cartilage repair tissue. We reviewed 52 patients who had arthroscopic implantation of the PGA-hyaluronan scaffold immersed with PRP in articular cartilage defects of the knee pretreated with Pridie drilling. Patients were assessed by KOOS. At 9 months followup, histologic staining was performed in specimens obtained from five patients to assess the repair tissue quality. The KOOS subscores improved for pain (55 to 91), symptoms (57 to 88), activities of daily living (69 to 86), sports and recreation (36 to 70), and quality of life (38 to 73). The histologic evaluation showed a homogeneous hyaline-like cartilage repair tissue. The cell-free PGA-hyaluronan scaffold combined with PRP leads to cartilage repair and improved patient-reported outcomes (KOOS) during 12 months of followup. Histologic sections showed morphologic features of hyaline-like repair tissue. Long-term followup is needed to determine if the cartilage repair tissue is durable. Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

  12. Formation and maturation of the murine meniscus.

    Science.gov (United States)

    Gamer, Laura W; Xiang, Lin; Rosen, Vicki

    2017-08-01

    Meniscal injuries are commonplace, but current surgical repair procedures do not prevent degenerative joint changes that occur after meniscal injury and often lead to osteoarthritis. Successful tissue regeneration in adults often recapitulates events that occur during embryogenesis, suggesting that understanding the regulatory pathways controlling these early processes may provide clues for developing strategies for tissue repair. While the mouse is now widely used to study joint diseases, detailed knowledge of the basic biology of murine meniscus is not readily available. Here, we examine meniscal morphogenesis in mice from embryonic day 13.5 (E13.5) to 6 months of age using histology, in situ hybridization, and immunohistochemistry. We find that the meniscus is a morphologically distinct structure at E16 when it begins to regionalize. At birth, the meniscus has a distinguishable inner, avascular, round chondrocyte cell region, an outer, vascularized, fibroblast cell region, and a surface superficial zone. Maturation begins at 2 weeks of age when the meniscus expresses type I collagen, type II collagen, type X collagen, and MMP-13 in specific patterns. By 4 weeks of age, small areas of ossification are detected in the anterior meniscal horn, a common feature seen in rodents. Maturation appears complete at 8 weeks of age, when the meniscus resembles the adult structure complete with ossifying tissue that contains bone marrow like areas. Our results provide, the first systematic study of mouse meniscal development and will be a valuable tool for analyzing murine models of knee joint formation and disease. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1683-1689, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  13. Turbine repair process, repaired coating, and repaired turbine component

    Science.gov (United States)

    Das, Rupak; Delvaux, John McConnell; Garcia-Crespo, Andres Jose

    2015-11-03

    A turbine repair process, a repaired coating, and a repaired turbine component are disclosed. The turbine repair process includes providing a turbine component having a higher-pressure region and a lower-pressure region, introducing particles into the higher-pressure region, and at least partially repairing an opening between the higher-pressure region and the lower-pressure region with at least one of the particles to form a repaired turbine component. The repaired coating includes a silicon material, a ceramic matrix composite material, and a repaired region having the silicon material deposited on and surrounded by the ceramic matrix composite material. The repaired turbine component a ceramic matrix composite layer and a repaired region having silicon material deposited on and surrounded by the ceramic matrix composite material.

  14. Long-term follow-up results of umbilical hernia repair.

    Science.gov (United States)

    Venclauskas, Linas; Jokubauskas, Mantas; Zilinskas, Justas; Zviniene, Kristina; Kiudelis, Mindaugas

    2017-12-01

    Multiple suture techniques and various mesh repairs are used in open or laparoscopic umbilical hernia (UH) surgery. To compare long-term follow-up results of UH repair in different hernia surgery groups and to identify risk factors for UH recurrence. A retrospective analysis of 216 patients who underwent elective surgery for UH during a 10-year period was performed. The patients were divided into three groups according to surgery technique (suture, mesh and laparoscopic repair). Early and long-term follow-up results including hospital stay, postoperative general and wound complications, recurrence rate and postoperative patient complaints were reviewed. Risk factors for recurrence were also analyzed. One hundred and forty-six patients were operated on using suture repair, 52 using open mesh and 18 using laparoscopic repair technique. 77.8% of patients underwent long-term follow-up. The postoperative wound complication rate and long-term postoperative complaints were significantly higher in the open mesh repair group. The overall hernia recurrence rate was 13.1%. Only 2 (1.7%) patients with small hernias ( 30 kg/m 2 , diabetes and wound infection were independent risk factors for umbilical hernia recurrence. The overall umbilical hernia recurrence rate was 13.1%. Body mass index > 30 kg/m 2 , diabetes and wound infection were independent risk factors for UH recurrence. According to our study results, laparoscopic medium and large umbilical hernia repair has slight advantages over open mesh repair concerning early postoperative complications, long-term postoperative pain and recurrence.

  15. Clinical Outcomes and Complications of Percutaneous Achilles Repair System Versus Open Technique for Acute Achilles Tendon Ruptures.

    Science.gov (United States)

    Hsu, Andrew R; Jones, Carroll P; Cohen, Bruce E; Davis, W Hodges; Ellington, J Kent; Anderson, Robert B

    2015-11-01

    Limited incision techniques for acute Achilles tendon ruptures have been developed in recent years to improve recovery and reduce postoperative complications compared with traditional open repair. The purpose of this retrospective cohort study was to analyze the clinical outcomes and postoperative complications between acute Achilles tendon ruptures treated using a percutaneous Achilles repair system (PARS [Arthrex, Inc, Naples, FL]) versus open repair and evaluate the overall outcomes for operatively treated Achilles ruptures. Between 2005 and 2014, 270 consecutive cases of operatively treated acute Achilles tendon ruptures were reviewed (101 PARS, 169 open). Patients with Achilles tendinopathy, insertional ruptures, chronic tears, or less than 3-month follow-up were excluded. Operative treatment consisted of a percutaneous technique (PARS) using a 2-cm transverse incision with FiberWire (Arthrex, Inc, Naples, FL) sutures or open repair using a 5- to 8-cm posteromedial incision with FiberWire in a Krackow fashion reinforced with absorbable sutures. Patient demographics were recorded along with medical comorbidities, activity at injury, time from injury to surgery, length of follow-up, return to baseline activities by 5 months, and postoperative complications. The most common activity during injury for both groups was basketball (PARS: 39%, open: 47%). A greater number of patients treated with PARS were able to return to baseline physical activities by 5 months compared with the open group (PARS: 98%, open: 82%; P = .0001). There were no significant differences (P > .05) between groups in rates of rerupture (P = 1.0), sural neuritis (P = .16), wound dehiscence (P = .74), superficial (P = .29) and/or deep infection (P = .29), or reoperation (P = .13). There were no deep vein thromboses (DVTs) or reruptures in either group. In the PARS group, there were no cases of sural neuritis, 3 cases (3%) of superficial wound dehiscence, and 2 reoperations (2%) for superficial

  16. Magnetic Resonance Imaging of Cartilage Repair

    Science.gov (United States)

    Trattnig, Siegfried; Winalski, Carl S.; Marlovits, Stephan; Jurvelin, Jukka S.; Welsch, Goetz H.; Potter, Hollis G.

    2011-01-01

    Articular cartilage lesions are a common pathology of the knee joint, and many patients may benefit from cartilage repair surgeries that offer the chance to avoid the development of osteoarthritis or delay its progression. Cartilage repair surgery, no matter the technique, requires a noninvasive, standardized, and high-quality longitudinal method to assess the structure of the repair tissue. This goal is best fulfilled by magnetic resonance imaging (MRI). The present article provides an overview of the current state of the art of MRI of cartilage repair. In the first 2 sections, preclinical and clinical MRI of cartilage repair tissue are described with a focus on morphological depiction of cartilage and the use of functional (biochemical) MR methodologies for the visualization of the ultrastructure of cartilage repair. In the third section, a short overview is provided on the regulatory issues of the United States Food and Drug Administration (FDA) and the European Medicines Agency (EMEA) regarding MR follow-up studies of patients after cartilage repair surgeries. PMID:26069565

  17. Repair technique for steam generator tubes using electroforming

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Ho; Jeong, Hyun Kyu; Seo, Moon Hong

    2001-07-01

    Pickering B CANDU Unit 5 had experienced leakage at sleeve/tube joint due to severe and local pitting in 1992{delta}1993. One year later, OHT developed electrosleeving techniques for steam generator tube repair which was applied at Pickering B CANDU Unit 5, Oconee Unit 1 and Callaway in 1994, 1995 and 1999 respectively. In the results of electrosleeved tube test, electrosleeve materials were stronger than mother tubes in mechanical properties and corrosion resistance under design criteria. Two analytical models were originally developed for estimating the failure temperature under severe accident transients. Electrosleeve, a structural layer of fine grained nickel is electroformed onto the strike by circulating an aqueous solution of Ni sulfate or sulfamate with NiCO3. The patents published by FTI said that the electrolyte for electroforming the structural layer contains a pinning agent to inhibit growth of metal grains in the electroformed layer. The pinning agent contains phosphoric, phosphorous acid, molybdenum. In localization of electrosleeving, there are some problems like as 1)low plating rate, 2)high residual stress, 3)alloy composition, 4)low material properties at high temperature. Ni-Fe plating exhibit anomalous codeposition; that is less noble metal, Fe, deposits preferentially to the more noble metal, Ni. Ductility decrease and residual stress increase with increase of Fe content in plate layer. Addition of particle size of 10{delta}400{mu}m makes residual stress compressive in plate layer. Composite plating show excellent high temperature properties.

  18. Repair technique for steam generator tubes using electroforming

    International Nuclear Information System (INIS)

    Kim, Seung Ho; Jeong, Hyun Kyu; Seo, Moon Hong

    2001-07-01

    Pickering B CANDU Unit 5 had experienced leakage at sleeve/tube joint due to severe and local pitting in 1992δ1993. One year later, OHT developed electrosleeving techniques for steam generator tube repair which was applied at Pickering B CANDU Unit 5, Oconee Unit 1 and Callaway in 1994, 1995 and 1999 respectively. In the results of electrosleeved tube test, electrosleeve materials were stronger than mother tubes in mechanical properties and corrosion resistance under design criteria. Two analytical models were originally developed for estimating the failure temperature under severe accident transients. Electrosleeve, a structural layer of fine grained nickel is electroformed onto the strike by circulating an aqueous solution of Ni sulfate or sulfamate with NiCO3. The patents published by FTI said that the electrolyte for electroforming the structural layer contains a pinning agent to inhibit growth of metal grains in the electroformed layer. The pinning agent contains phosphoric, phosphorous acid, molybdenum. In localization of electrosleeving, there are some problems like as 1)low plating rate, 2)high residual stress, 3)alloy composition, 4)low material properties at high temperature. Ni-Fe plating exhibit anomalous codeposition; that is less noble metal, Fe, deposits preferentially to the more noble metal, Ni. Ductility decrease and residual stress increase with increase of Fe content in plate layer. Addition of particle size of 10δ400μm makes residual stress compressive in plate layer. Composite plating show excellent high temperature properties

  19. Suture spanning augmentation of single-row rotator cuff repair: a biomechanical analysis.

    Science.gov (United States)

    Early, Nicholas A; Elias, John J; Lippitt, Steven B; Filipkowski, Danielle E; Pedowitz, Robert A; Ciccone, William J

    2017-02-01

    This in vitro study evaluated the biomechanical benefit of adding spanning sutures to single-row rotator cuff repair. Mechanical testing was performed to evaluate 9 pairs of cadaveric shoulders with complete rotator cuff repairs, with a single-row technique used on one side and the suture spanning technique on the other. The spanning technique included sutures from 2 lateral anchors securing tendon near the musculotendinous junction, spanning the same anchor placement from single-row repair. The supraspinatus muscle was loaded to 100 N at 0.25 Hz for 100 cycles, followed by a ramp to failure. Markers and a video tracking system measured anterior and posterior gap formation across the repair at 25-cycle intervals. The force at which the stiffness decreased by 50% and 75% was determined. Data were compared using paired t-tests. One single-row repair failed at row repairs than for the suture spanning technique. The difference was statistically significant at all cycles for the posterior gap formation (P ≤ .02). The trends were not significant for the anterior gap (P ≥ .13). The loads at which the stiffness decreased by 50% and 75% did not differ significantly between the 2 types of repair (P ≥ .10). The suture spanning technique primarily improved posterior gap formation. Decreased posterior gap formation could reduce failure rates for rotator cuff repair. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  20. Footprint Contact Area and Interface Pressure Comparison Between the Knotless and Knot-Tying Transosseous-Equivalent Technique for Rotator Cuff Repair.

    Science.gov (United States)

    Kim, Sung-Jae; Kim, Sung-Hwan; Moon, Hyun-Soo; Chun, Yong-Min

    2016-01-01

    To quantify and compare the footprint contact area and interface pressure on the greater tuberosity between knotless and knot-tying transosseous-equivalent (TOE) repair using pressure-sensitive film. We used 11 pairs of fresh-frozen cadaveric shoulders (22 specimens), in which rotator cuff tears were created before repair. Each pair was randomized to either conventional medial knot-tying TOE repair (group A) or medial knotless TOE repair using the modified Mason-Allen technique (group B). Pressure-sensitive film was used to quantify the pressurized contact area and interface pressure between the greater tuberosity and supraspinatus tendon. The mean pressurized contact area was 33.2 ± 2.5 mm(2) for group A and 28.4 ± 2.4 mm(2) for group B. There was a significant difference between groups (P = .005). Although the overall contact configuration of both groups was similar and showed an M shape, group A showed a greater pressurized configuration around the medial row. The mean interface pressure was 0.20 ± 0.02 MPa for group A and 0.17 ± 0.02 MPa for group B. There was a significant difference between groups (P = .001). Contrary to our hypothesis, in this time-zero study, medial knotless TOE repair using a modified Mason-Allen suture produced a significantly inferior footprint contact area and interface pressure compared with conventional medial knot-tying TOE repair. Even though we found a statistically significant difference between the 2 repair methods, it is still unknown if this statistical difference seen in our study has any clinical and radiologic significance. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  1. Preliminary report of a sutureless onlay technique for incisional hernia repair using fibrin glue alone for mesh fixation.

    Science.gov (United States)

    Stoikes, Nathaniel; Webb, David; Powell, Ben; Voeller, Guy

    2013-11-01

    The Rives repair for ventral/incisional (V/I) hernias involves sublay mesh placement requiring retrorectus dissection and transfascial stitches. Chevrel described a repair by onlaying mesh after a unique primary fascial closure. Although Chevrel fixated mesh to the anterior fascia with sutures, he used fibrin glue for fascial closure reinforcement. We describe an onlay technique with mesh fixated to the anterior fascia solely with fibrin glue without suture fixation. From January 2010 to January 2012, 50 patients underwent a V/I hernia onlay technique with fibrin glue mesh fixation. Records were reviewed for technical details, demographics, mesh characteristics, and postoperative outcomes. Primary fascial closure with interrupted permanent suture was done with or without myofascial advancement flaps. Onlay polypropylene mesh was placed providing 8 cm of overlap. Fibrin glue was applied over the prosthesis and subcutaneous drains were placed. Mean age was 62.4 years. Mean body mass index was 30.1 kg/m(2). Average mesh size was 14.5 cm × 19.1 cm. Mean operative time was 144.4 minutes (range, 38 to 316 minutes). Mean discharge was postoperative Day 2.9 (range, 0 to 15 days). Morbidity included eight seromas, one hematoma, and three wound infections. Seventeen patients required components separation. Mean follow-up was 19.5 months with no recurrences. This is the first series describing fibrin glue alone for mesh fixation for V/I hernia repair. It allows for immediate prosthesis fixation to the anterior fascia. Early results are promising. Potential advantages include less operative time, less technical difficulty, and less long-term pain. A prospective trial is needed to evaluate this approach.

  2. Leak testing and repair of fusion devices

    International Nuclear Information System (INIS)

    Kozman, T.A.

    1983-01-01

    The leak testing, reporting and vacuum leak repair techniques of the MFTF yin-yang number one magnet system, the world's largest superconducting magnet system, are discussed. Based on this experience, techniques will be developed for testing and repairing leaks on the 42 MFTF-B magnets. The leak-hunting techniques for the yin-yang magnet systems were applied to two helium circuits (the coil bundle and guard vacuum; both require helium flow for magnet cooldown), their associated piping, liquid nitrogen radiation shields, and piping. Additionally, during MFTF-B operation there will be warm water plasma shields and piping that require leak checking

  3. Chronologic and Geographic Trends of Triangular Fibrocartilage Complex Repair.

    Science.gov (United States)

    Saito, Taichi; Sterbenz, Jennifer M; Chung, Kevin C

    2017-11-01

    This article shows trends in triangular fibrocartilage complex (TFCC) repair since 1990 by geographic area and year. The repair methods presented in the literature were inside-out, outside-in, all-inside, and open repair. The outside-in technique was reported most often for ulnar-side tears, whereas the inside-out technique was reported most frequently for radial-side tears. Recently, a foveal reattachment technique for ulnar-side tears has garnered attention and has been reported with increasing frequency, especially in Asia, because the deepest portion of TFCC, attached to fovea, plays a key role in stabilizing the distal radioulnar joint. Understanding these trends can help clinicians best treat TFCC tears. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Underwater inspection, repair and reconstitution of water reactor fuel

    International Nuclear Information System (INIS)

    1988-06-01

    On-site fuel examination plays an important role for evaluation of fuel irradiation performance under reactor operating conditions. Also fuel assembly repairs are economically very attractive for operating nuclear utilities. The status of the processes of examination and repair, equipment used and research plans in Member States are reviewed in these Proceedings. All presentations were divided into three sessions: inspection diagnostic: facilities, techniques, and programmes (8 papers); repair and reconstitution techniques (6 papers); power plant experience (6 papers). A separate abstract was prepared for each of these 20 papers. Refs, figs and tabs

  5. Scarf Repair of Composite Laminates

    Directory of Open Access Journals (Sweden)

    Xie Zonghong

    2016-01-01

    Full Text Available The use of composite materials, such as carbon-fiber reinforced plastic (CFRP composites, aero-structures has led to an increased need of advanced assembly joining and repair technologies. Adhesive bonded repairs as an alternative to recover full or part of initial strength were investigated. Tests were conducted with the objective of evaluating the effectiveness of techniques used for repairing damage fiber reinforced laminated composites. Failure loads and failure modes were generated and compared with the following parameters: scarf angles, roughness of grind tool and number of external plies. Results showed that scarf angle was the critical parameter and the largest tensile strength was observed with the smallest scarf angle. Besides, the use of external plies at the outer surface could not increase the repairs efficiency for large scarf angle. Preparing the repair surfaces by sanding them with a sander ranging from 60 to 100 grit number had significant effect on the failure load. These results allowed the proposal of design principles for repairing CFRP structures.

  6. Overlapping sphincteroplasty and posterior repair.

    Science.gov (United States)

    Crane, Andrea K; Myers, Erinn M; Lippmann, Quinn K; Matthews, Catherine A

    2014-12-01

    Knowledge of how to anatomically reconstruct extensive posterior-compartment defects is variable among gynecologists. The objective of this video is to demonstrate an effective technique of overlapping sphincteroplasty and posterior repair. In this video, a scripted storyboard was constructed that outlines the key surgical steps of a comprehensive posterior compartment repair: (1) surgical incision that permits access to posterior compartment and perineal body, (2) dissection of the rectovaginal space up to the level of the cervix, (3) plication of the rectovaginal muscularis, (4) repair of internal and external anal sphincters, and (5) reconstruction of the perineal body. Using a combination of graphic illustrations and live video footage, tips on repair are highlighted. The goals at the end of repair are to: (1) have improved vaginal caliber, (2) increase rectal tone along the entire posterior vaginal wall, (3) have the posterior vaginal wall at a perpendicular plane to the perineal body, (4) reform the hymenal ring, and (5) not have an overly elongated perineal body. This video provides a step-by-step guide on how to perform an overlapping sphincteroplasty and posterior repair.

  7. Urinary function after Snodgrass repair of distal hypospadias: comparison with the Mathieu repair.

    Science.gov (United States)

    Scarpa, Maria Grazia; Castagnetti, Marco; Berrettini, Alfredo; Rigamonti, Waifro; Musi, Luciano

    2010-05-01

    To evaluate urinary function in patients with distal hypospadias undergoing repair by the tubularized incised-plate urethroplasty (TIP or Snodgrass), compare the results with those in patients treated by the Mathieu technique, and show the potential issues inherent to the evaluation of such results. A cross-sectional assessment was performed of uncomplicated distal hypospadias operated on during a 3-year period, already toilet trained, and able to void volitionally. Evaluation included clinical assessment urinary symptoms and urinary stream, and uroflowmetry. Out of 83 patients operated on during the study period, 10 (12%) developed complication and 32 were not toilet trained or refused to participate in the study. Median follow-up in the remaining 41 patients included in the study was 20 (3-36) months. None of these patients presented voiding symptoms or urinary stream abnormalities. Uroflowmetry was normal in 30 cases and obstructive in 11 (27%). An obstructive flow pattern was more common in patients undergoing TIP versus Mathieu repair, 8 of 19 (42%) versus 3 of 22 (14%), respectively (P = 0.07). Four TIP cases with an obstructive uroflow pattern were managed conservatively. Although both the TIP and the Mathieu repair allow good results in terms of urinary function after distal hypospadias repairs, the TIP technique seems more likely to be associated with urine flow pattern abnormalities. The actual clinical relevance of this finding remains ill defined.

  8. Single- and double-row repair for rotator cuff tears - biology and mechanics.

    Science.gov (United States)

    Papalia, Rocco; Franceschi, Francesco; Vasta, Sebastiano; Zampogna, Biagio; Maffulli, Nicola; Denaro, Vincenzo

    2012-01-01

    We critically review the existing studies comparing the features of single- and double-row repair, and discuss suggestions about the surgical indications for the two repair techniques. All currently available studies comparing the biomechanical, clinical and the biological features of single and double row. Biomechanically, the double-row repair has greater performances in terms of higher initial fixation strength, greater footprint coverage, improved contact area and pressure, decreased gap formation, and higher load to failure. Results of clinical studies demonstrate no significantly better outcomes for double-row compared to single-row repair. Better results are achieved by double-row repair for larger lesions (tear size 2.5-3.5 cm). Considering the lack of statistically significant differences between the two techniques and that the double row is a high cost and a high surgical skill-dependent technique, we suggest using the double-row technique only in strictly selected patients. Copyright © 2012 S. Karger AG, Basel.

  9. Radiation repair models for clinical application.

    Science.gov (United States)

    Dale, Roger G

    2018-02-28

    A number of newly emerging clinical techniques involve non-conventional patterns of radiation delivery which require an appreciation of the role played by radiation repair phenomena. This review outlines the main models of radiation repair, focussing on those which are of greatest clinical usefulness and which may be incorporated into biologically effective dose assessments. The need to account for the apparent "slowing-down" of repair rates observed in some normal tissues is also examined, along with a comparison of the relative merits of the formulations which can be used to account for such phenomena. Jack Fowler brought valuable insight to the understanding of radiation repair processes and this article includes reference to his important contributions in this area.

  10. Repair-welding technology of irradiated materials - WIM project

    International Nuclear Information System (INIS)

    Nakata, K.; Oishi, M.

    1998-01-01

    A new project on the development of repair-welding technology for core internals and reactor (pressure) vessel, consigned by the Ministry of International Trade and Industry (MITI), has been started from October 1997. The objective of the project is classified into three points as follows: (1) to develop repair-welding techniques for neutron irradiated materials, (2) to prove the availability of the techniques for core internals and reactor (pressure) vessel, and (3) to recommend the updated repair-welding for the Technical Rules and Standards. Total planning, neutron irradiation, preparation of welding equipment are now in progress. The materials are austenitic stainless steels and a low alloy steel. Neutron irradiation is performed using test reactors. In order to suppress the helium aggregation along grain boundaries, low heat input welding techniques, such as laser, low heat input TIG and friction weldings, will be applied. (author)

  11. Biomechanical analysis of a salt-modified polyvinyl alcohol hydrogel for knee meniscus applications, including comparison with human donor samples.

    Science.gov (United States)

    Hayes, Jennifer C; Curley, Colin; Tierney, Paul; Kennedy, James E

    2016-03-01

    The primary objective of this research was the biomechanical analysis of a salt-modified polyvinyl alcohol hydrogel, in order to assess its potential for use as an artificial meniscal implant. Aqueous polyvinyl alcohol (PVA) was treated with a sodium sulphate (Na2SO4) solution to precipitate out the polyvinyl alcohol resulting in a pliable hydrogel. The freeze-thaw process, a strictly physical method of crosslinking, was employed to crosslink the hydrogel. Development of a meniscal shaped mould and sample housing unit allowed the production of meniscal shaped hydrogels for direct comparison to human meniscal tissue. Results obtained show that compressive responses were slightly higher in PVA/Na2SO4 menisci, displaying maximum compressive loads of 2472N, 2482N and 2476N for samples having undergone 1, 3 and 5 freeze-thaw cycles respectively. When compared to the human meniscal tissue tested under the same conditions, an average maximum load of 2467.5N was observed. This suggests that the PVA/Na2SO4 menisci are mechanically comparable to the human meniscus. Biocompatibility analysis of PVA/Na2SO4 hydrogels revealed no acute cytotoxicity. The work described herein has innovative potential in load bearing applications, specifically as an alternative to meniscectomy as replacement of critically damaged meniscal tissue in the knee joint where repair is not viable. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. The "Batman flap": a novel technique to repair a large central glabellar defect.

    Science.gov (United States)

    Puviani, Mario; Curci, Marco

    2018-04-01

    Given the critical position of central glabella among the frontal, nasal, and supraorbital aesthetic subunits of the face, the reconstruction of large defects in this area represents a surgical challenge. We describe a surgical technique based on a modified, curved, A-T flap to repair a large glabellar defect. Our modification is useful for large glabellar defects because it enables the distribution of the tension all over the reconstruction sides, avoiding a stressed central area and the subsequent risk of necrosis; functionally, it respects the eyebrows position and since the advancement is parallel to their major axes, it avoids the reduction of the distance between them. The "Batman flap" enables reconstructing a glabellar defect, with a good aesthetical result and the respect of the relevant aesthetical subunits. © 2017 The International Society of Dermatology.

  13. A comparison of the DNA and chromosome repair kinetics after #betta# irradiation

    International Nuclear Information System (INIS)

    Hittelman, W.N.; Pollard, M.

    1982-01-01

    The kinetics of repair at the chromosome and DNA levels were compared after #betta# irradiation of Chinese hamster ovary cells (CHO). Induction and repair of DNA damage were measured by the alkaline and neutral elution techniques, while chromosome damage and repair were determined by the technique of premature chromosome condensation. During and after #betta# irradiation, significant DNA repair occurred within 2 min. This fast repair could be inhibited by EDTA and pyrophosphate and probably reflected polynucleotide ligase activity. A slower component of DNA repair was detected between 15 and 60 min after irradiation, by which time most of the DNA had been repaired. In contrast, chromosome repair was not detectable until 45 min after irradiation, and nearly half of the chromatid breaks were repaired by 60 min. Cycloheximide, an inhibitor of protein synthesis, prevented chromosome break repair, yet had no effect on the immediate formation of chromatid exchanges or DNA repair. These results suggest the following: (1) the rapidly repairing DNA lesions are not important in the repair of chromosomes; (2) chromosome damage involves only a minority of the DNA lesions measured by alkaline and neutral DNA elution; and (3) chromosome repair may involve more than simply the repair of damaged DNA that can be detected by the alkaline and neutral elution assays

  14. Laparoscopic inguinal preperitoneal injection--novel technique for inguinal hernia repair: preliminary results of experimental study.

    Science.gov (United States)

    Kozlov, Yury; Novogilov, Vladimir; Rasputin, Andrey; Podkamenev, Alexey; Krasnov, Pavel; Weber, Irina; Solovjev, Alexey

    2012-04-01

    Inguinal hernia repair is the most common procedure in pediatric surgery. Suture techniques for laparoscopic inguinal hernia repair in children are easy to perform and popular with a low recurrence rate. The aim of this study was to evaluate the effect of laparoscopic preperitoneal injection of three-dimensional gel on closing of the inguinal hernia sac (IHS) in laboratory animals. With the animals under general anesthesia, we performed peritoneoscopy in 12 male Chinchilla rabbits weighing 1200-1400 g. The endoscope was introduced into the abdominal cavity, and bilateral deep inguinal rings were identified. A Tuohy needle with the injectable polymeric bulking agent DAM+™ (three-dimensional polyacrylamide gel with silver ions [Argiform(®) from Bioform(®)]) was introduced preperitoneally. The implant was then injected across the entire orifice of the deep inguinal rings and draped over the cord structures. After completion of bilateral repairs, the rabbits were extubated and observed in the animal laboratory. Then the second laparoscopy was performed 6 months later, and the deep inguinal rings were inspected. The postoperative course was uneventful in all the animals. At the second laparoscopy no reopening of the entire orifice of the deep inguinal rings was noted. Accurate placement of the polymeric agent and adequate coverage of the vas deferens were accomplished in all the animals. This study demonstrates that the biopolymeric implant gives good postoperative results and a stable trend of closing the IHS in long-term follow-up. In conclusion, we hope that injectable polymeric bulking agents can be used for treatment of inguinal hernias of pediatric patients after additional animal and human research.

  15. Repair process and a repaired component

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, III, Herbert Chidsey; Simpson, Stanley F.

    2018-02-20

    Matrix composite component repair processes are disclosed. The matrix composite repair process includes applying a repair material to a matrix composite component, securing the repair material to the matrix composite component with an external securing mechanism and curing the repair material to bond the repair material to the matrix composite component during the securing by the external securing mechanism. The matrix composite component is selected from the group consisting of a ceramic matrix composite, a polymer matrix composite, and a metal matrix composite. In another embodiment, the repair process includes applying a partially-cured repair material to a matrix composite component, and curing the repair material to bond the repair material to the matrix composite component, an external securing mechanism securing the repair material throughout a curing period, In another embodiment, the external securing mechanism is consumed or decomposed during the repair process.

  16. Inguinal hernia repair: anaesthesia, pain and convalescence

    DEFF Research Database (Denmark)

    Callesen, Torben

    2003-01-01

    of less serious complications is lower by local anaesthesia, compared to other anaesthetic techniques. Of special interest is, that the rate of urinary retention can be eliminated by the use of local anaesthesia. Local anaesthesia results, in comparative studies, in a higher degree of patient satisfaction...... than other anaesthetic techniques. Local anaesthesia also facilitates faster mobilisation and earlier discharge/fulfilment of discharge criteria from post anaesthetic care units than other anaesthetic techniques. Pain after hernia repair is more pronounced at mobilisation or coughing than during rest....... Pain after laparoscopic surgery is less pronounced than after open surgery, while different open repair techniques do not exhibit significant differences. Postoperative pain is best treated with a combination of local analgesia and peripherally acting agents (paracetamol, NSAID or their combination...

  17. Staged abdominal closure with intramuscular tissue expanders and modified components separation technique of a giant incisional hernia after repair of a ruptured omphalocele

    Directory of Open Access Journals (Sweden)

    Yukihiro Tatekawa

    2016-07-01

    Full Text Available In patients with omphalocele, several different techniques are performed for repair of the abdominal wall defect. We present the case of a staged abdominal closure of a giant incisional hernia after repair of a ruptured omphalocele. At birth, skin flap coverage associated with silo formation occurred, but the abdominal wall defect remained, resulting in a giant abdominal hernia. To expand the layers of the abdominal wall, tissue expanders were placed between the bilateral internal oblique and transverses abdominis muscles. Postoperatively, a modified components separation technique was performed. The abdominal wall was closed in the midline. Upon closure of the skin in the midline, bilateral relaxing incisions were performed, covering the remaining defect with artificial dermis. At the age of one year and 7 months, the patient had no recurrent incisional hernia nor any wound complications.

  18. Double-Row Capsulolabral Repair Increases Load to Failure and Decreases Excessive Motion.

    Science.gov (United States)

    McDonald, Lucas S; Thompson, Matthew; Altchek, David W; McGarry, Michelle H; Lee, Thay Q; Rocchi, Vanna J; Dines, Joshua S

    2016-11-01

    Using a cadaver shoulder instability model and load-testing device, we compared biomechanical characteristics of double-row and single-row capsulolabral repairs. We hypothesized a greater reduction in glenohumeral motion and translation and a higher load to failure in a mattress double-row capsulolabral repair than in a single-row repair. In 6 matched pairs of cadaveric shoulders, a capsulolabral injury was created. One shoulder was repaired with a single-row technique, and the other with a double-row mattress technique. Rotational range of motion, anterior-inferior translation, and humeral head kinematics were measured. Load-to-failure testing measured stiffness, yield load, deformation at yield load, energy absorbed at yield load, load to failure, deformation at ultimate load, and energy absorbed at ultimate load. Double-row repair significantly decreased external rotation and total range of motion compared with single-row repair. Both repairs decreased anterior-inferior translation compared with the capsulolabral-injured condition, however, no differences existed between repair types. Yield load in the single-row group was 171.3 ± 110.1 N, and in the double-row group it was 216.1 ± 83.1 N (P = .02). Ultimate load to failure in the single-row group was 224.5 ± 121.0 N, and in the double-row group it was 373.9 ± 172.0 N (P = .05). Energy absorbed at ultimate load in the single-row group was 1,745.4 ± 1,462.9 N-mm, and in the double-row group it was 4,649.8 ± 1,930.8 N-mm (P = .02). In cases of capsulolabral disruption, double-row repair techniques may result in decreased shoulder rotational range of motion and improved load-to-failure characteristics. In cases of capsulolabral disruption, repair techniques with double-row mattress repair may provide more secure fixation. Double-row capsulolabral repair decreases shoulder motion and increases load to failure, yield load, and energy absorbed at yield load more than single-row repair. Published by

  19. Study on Repaired Earthquake-Damaged Bridge Piers under Seismic Load

    Directory of Open Access Journals (Sweden)

    Jun Deng

    2015-01-01

    Full Text Available The concrete bridge pier damaged during earthquakes need be repaired to meet the design standards. Steel tube as a traditional material or FRP as a novel material has become popular to repair the damaged reinforced concrete (RC bridge piers. In this paper, experimental and finite element (FE studies are employed to analyze the confinement effectiveness of the different repair materials. The FE method was used to calculate the hysteretic behavior of three predamaged circle RC bridge piers repaired with steel tube, basalt fiber reinforced polymer (BFRP, and carbon fiber reinforced polymer (CFRP, respectively. Meanwhile, the repaired predamaged circle concrete bridge piers were tested by pseudo-static cyclic loading to study the seismic behavior and evaluate the confinement effectiveness of the different repair materials and techniques. The FE analysis and experimental results showed that the repaired piers had similar hysteretic curves with the original specimens and all the three repair techniques can restore the seismic performance of the earthquake-damaged piers. Steel tube jacketing can significantly improve the lateral stiffness and peak load of the damaged pier, while the BFRP and CFRP sheets cannot improve these properties due to their thin thickness.

  20. Male Fertility After Inguinal Hernia Mesh Repair

    DEFF Research Database (Denmark)

    Kohl, Andreas Pagh; Andresen, Kristoffer; Rosenberg, Jacob

    2017-01-01

    OBJECTIVE:: To determine whether patients who receive an inguinal hernia repair father the same number of children as the background population. BACKGROUND:: Although the effect of inguinal hernia repair on male fertility has previously been investigated through indirect measures, no previous...... studies have evaluated the final measure of male fertility, which is the number of children fathered by patients. METHODS:: Prospectively collected data on 32,621 male patients between the ages of 18 and 55 years who received 1 or more inguinal hernia repairs during the years 1998 to 2012 were found in 5...... hernia repair using Lichtenstein technique or laparoscopic approach did not father fewer children than expected. Thus, inguinal hernia repair using Lichtenstein or laparoscopic approach did not impair male fertility....

  1. Incidence of retear with double-row versus single-row rotator cuff repair.

    Science.gov (United States)

    Shen, Chong; Tang, Zhi-Hong; Hu, Jun-Zu; Zou, Guo-Yao; Xiao, Rong-Chi

    2014-11-01

    Rotator cuff tears have a high recurrence rate, even after arthroscopic rotator cuff repair. Although some biomechanical evidence suggests the superiority of the double-row vs the single-row technique, clinical findings regarding these methods have been controversial. The purpose of this study was to determine whether the double-row repair method results in a lower incidence of recurrent tearing compared with the single-row method. Electronic databases were systematically searched to identify reports of randomized, controlled trials (RCTs) comparing single-row with double-row rotator cuff repair. The primary outcome assessed was retear of the repaired cuff. Secondary outcome measures were the American Shoulder and Elbow Surgeons (ASES) shoulder score, the Constant shoulder score, and the University of California, Los Angeles (UCLA) score. Heterogeneity between the included studies was assessed. Six studies involving 428 patients were included in the review. Compared with single-row repair, double-row repair demonstrated a lower retear incidence (risk ratio [RR]=1.71 [95% confidence interval (CI), 1.18-2.49]; P=.005; I(2)=0%) and a reduced incidence of partial-thickness retears (RR=2.16 [95% CI, 1.26-3.71]; P=.005; I(2)=26%). Functional ASES, Constant, and UCLA scores showed no difference between single- and double-row cuff repairs. Use of the double-row technique decreased the incidence of retears, especially partial-thickness retears, compared with the single-row technique. The functional outcome was not significantly different between the 2 techniques. To improve the structural outcome of the repaired rotator cuff, surgeons should use the double-row technique. However, further long-term RCTs on this topic are needed. Copyright 2014, SLACK Incorporated.

  2. Cleft Palate Repair Using a Double Opposing Z-Plasty.

    Science.gov (United States)

    Moores, Craig; Shah, Ajul; Steinbacher, Derek M

    2016-07-01

    Cleft palate is a common congenital defect with several described surgical repairs. The most successful treatment modality remains a controversy. The goals of repair focus on achievement of normal speech and optimizing velopharyngeal function while minimizing both fistula formation and facial growth restriction. In this video, the authors demonstrate use of the double opposing Z-plasty technique in the repair of a Veau II type cleft palate. The video demonstrates the marking, incisions, dissection, and repair of the cleft. It also examines the use of von Langenbeck-type relaxing incisions and demonstrates a specific approach to the repair of this particular cleft. The authors believe that the Furlow double opposing Z-plasty with the von Langenbeck relaxing incision can provide the best postoperative outcome by combining the benefits of each individual operation. The Z-plasty technique works to correct the aberrant muscle of the soft palate while increasing the length of the palate. The authors believe that this results in better velopharyngeal function.

  3. The temporal outcomes of open versus arthroscopic knotted and knotless rotator cuff repair over 5 years

    Science.gov (United States)

    Lucena, Thomas R; Lam, Patrick H; Millar, Neal L

    2015-01-01

    Background The present study aimed to determine how repair technique influenced structural and clinical outcomes at 5 years post-surgery. Methods Three cohorts of patients had repair of a symptomatic rotator cuff tear using (i) an open double-row mattress repair technique (n = 25); (ii) arthroscopic single-row simple suture knotted technique (n = 25); or (iii) arthroscopic single-row inverted mattress knotless technique (n = 36) by one surgeon. Standardized patient- and examiner-determined outcomes were obtained pre-operatively and postoperatively with a validated protocol, ultrasound were also performed at the same time. Results Retear occurred more often after open repair (48%) at 5 years than after arthroscopic knotted (33%) and arthroscopic knotless (26%) repair. Retear was associated with increasing age, pre-operative tear size and weaker pre-operative and 5 years postoperative cuff strength. Between 2 years and 5 years, the open repair group experienced an increase in the frequency of pain during activity, as well as in the difficulty experienced and the severity of pain during overhead activities (p repair group. Conclusions At 5-year follow-up, arthroscopic rotator cuff repair techniques resulted in fewer retears and better outcomes compared to an open double-row technique. PMID:27582985

  4. Repair technology for steam generator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Ho; Jung, Hyun Kyu; Jung, Seung Ho; Kim, Chang Hoi; Jung, Young Moo; Seo, Yong Chil; Kim, Jung Su; Seo, Moo Hong

    2001-02-01

    The most commonly used sleeving materials are thermally treated Alloy 600 and thermally treated Alloy 690 Alloy. Currently, thermally treated Alloy 690 and Alloy 800 are being offered although Alloy 800 has not been licensed in the US. To install sleeve, joint strength, leak tightness, PWSCC resistance, evaluation on process parameter range and the effect of equipments and procedures on repair plan and radiation damage have to be investigated before sleeving. ABB CE provides three type of leak tight Alloy 690 TIG welded and PLUSS sleeve. Currently, Direct Tube Repair technique using Nd:YAG laser has been developed by ABB CE and Westinghouse. FTI has brazed and kinetic sleeve designs for recirculating steam generator and hydraulic and rolled sleeve designs for one-through steam generators. Westinghouse provides HEJ, brazed and laser welded sleeve design. When sleeve is installed in order to repair the damaged S/G tubes, it is certain that defects can be occurred due to the plastic induced stress and thermal stress. Therefore it is important to minimize the residual stress. FTI provides the electrosleeve technique as a future repair candidate using electroplating.

  5. Repair technology for steam generator tubes

    International Nuclear Information System (INIS)

    Kim, Seung Ho; Jung, Hyun Kyu; Jung, Seung Ho; Kim, Chang Hoi; Jung, Young Moo; Seo, Yong Chil; Kim, Jung Su; Seo, Moo Hong

    2001-02-01

    The most commonly used sleeving materials are thermally treated Alloy 600 and thermally treated Alloy 690 Alloy. Currently, thermally treated Alloy 690 and Alloy 800 are being offered although Alloy 800 has not been licensed in the US. To install sleeve, joint strength, leak tightness, PWSCC resistance, evaluation on process parameter range and the effect of equipments and procedures on repair plan and radiation damage have to be investigated before sleeving. ABB CE provides three type of leak tight Alloy 690 TIG welded and PLUSS sleeve. Currently, Direct Tube Repair technique using Nd:YAG laser has been developed by ABB CE and Westinghouse. FTI has brazed and kinetic sleeve designs for recirculating steam generator and hydraulic and rolled sleeve designs for one-through steam generators. Westinghouse provides HEJ, brazed and laser welded sleeve design. When sleeve is installed in order to repair the damaged S/G tubes, it is certain that defects can be occurred due to the plastic induced stress and thermal stress. Therefore it is important to minimize the residual stress. FTI provides the electrosleeve technique as a future repair candidate using electroplating

  6. TEMS: an alternative method for the repair of benign recto-vaginal fistulae.

    Science.gov (United States)

    Darwood, R J; Borley, N R

    2008-07-01

    The repair of high recto-vaginal fistula can be challenging since access may be limited via the endo-anal approach yet the alternative trans-abdominal route carries significant morbidity. We report the use of TEMS to repair a recto-vaginal fistula following anterior resection and pelvic radiotherapy. The patient was placed prone and a 25 cm rectoscope was inserted. A proximally based mucosal advancement flap was raised to repair the fistula. The patient was discharged 2 days later and a contrast study confirmed closure of the fistula. COMPARISON WITH OTHER TECHNIQUES: TEMS allows excellent visualisation of a rectovaginal fistula compared to standard endo-anal or trans-vaginal techniques. The morbidity is lower than the trans-abdominal route. TEMS is a useful technique for the repair of benign recto-vaginal fistula and has distinct advantages over conventional techniques.

  7. Meniscal Allograft Transplantation Does Not Prevent or Delay Progression of Knee Osteoarthritis.

    Directory of Open Access Journals (Sweden)

    Catherine Van Der Straeten

    Full Text Available Meniscal tears are common knee injuries. Meniscal allograft transplantation (MAT has been advocated to alleviate symptoms and delay osteoarthritis (OA after meniscectomy. We investigated (1 the long-term outcome of MAT as a treatment of symptomatic meniscectomy, (2 most important factors affecting survivorship and (3 OA progression.From 1989 till 2013, 329 MAT were performed in 313 patients. Clinical and radiographic results and MAT survival were evaluated retrospectively. Failure was defined as conversion to knee arthroplasty (KA or total removal of the MAT.Mean age at surgery was 33 years (15-57; 60% were males. No-to-mild cartilage damage was found in 156 cases, moderate-to-severe damage in 130. Simultaneous procedures in 118 patients included cartilage procedures, osteotomy or ACL-reconstruction. At a mean follow-up of 6.8 years (0.2-24.3years, 5 patients were deceased and 48 lost (14.6%, 186 MAT were in situ (56.5% whilst 90 (27.4% had been removed, including 63 converted to a KA (19.2%. Cumulative allograft survivorship was 15.1% (95% CI:13.9-16.3 at 24.0 years. In patients <35 years at surgery, survival was significantly better (24.1% compared to ≥35 years (8.0% (p = 0.017. In knees with no-to-mild cartilage damage more allografts survived (43.0% compared to moderate-to-severe damage (6.6% (p = 0.003. Simultaneous osteotomy significantly deteriorated survival (0% at 24.0 years (p = 0.010. 61% of patients underwent at least one additional surgery (1-11 for clinical symptoms after MAT. Consecutive radiographs showed significant OA progression at a mean of 3.8 years (p<0.0001. Incremental Kellgren-Lawrence grade was +1,1 grade per 1000 days (2,7yrs.MAT did not delay or prevent tibiofemoral OA progression. 19.2% were converted to a knee prosthesis at a mean of 10.3 years. Patients younger than 35 with no-to-mild cartilage damage may benefit from MAT for relief of symptoms (survivorship 51.9% at 20.2 years, but patients and healthcare payers

  8. Oxygen tension is a determinant of the matrix-forming phenotype of cultured human meniscal fibrochondrocytes.

    Directory of Open Access Journals (Sweden)

    Adetola B Adesida

    Full Text Available BACKGROUND: Meniscal cartilage displays a poor repair capacity, especially when injury is located in the avascular region of the tissue. Cell-based tissue engineering strategies to generate functional meniscus substitutes is a promising approach to treat meniscus injuries. Meniscus fibrochondrocytes (MFC can be used in this approach. However, MFC are unable to retain their phenotype when expanded in culture. In this study, we explored the effect of oxygen tension on MFC expansion and on their matrix-forming phenotype. METHODOLOGY/PRINCIPAL FINDINGS: MFC were isolated from human menisci followed by basic fibroblast growth factor (FGF-2 mediated cell expansion in monolayer culture under normoxia (21%O(2 or hypoxia (3%O(2. Normoxia and hypoxia expanded MFC were seeded on to a collagen scaffold. The MFC seeded scaffolds (constructs were cultured in a serum free chondrogenic medium for 3 weeks under normoxia and hypoxia. Constructs containing normoxia-expanded MFC were subsequently cultured under normoxia while those formed from hypoxia-expanded MFC were subsequently cultured under hypoxia. After 3 weeks of in vitro culture, the constructs were assessed biochemically, histologically and for gene expression via real-time reverse transcription-PCR assays. The results showed that constructs under normoxia produced a matrix with enhanced mRNA ratio (3.5-fold higher; p<0.001 of collagen type II to I. This was confirmed by enhanced deposition of collagen II using immuno-histochemistry. Furthermore, the constructs under hypoxia produced a matrix with higher mRNA ratio of aggrecan to versican (3.5-fold, p<0.05. However, both constructs had the same capacity to produce a glycosaminoglycan (GAG -specific extracellular matrix. CONCLUSIONS: Our data provide evidence that oxygen tension is a key player in determining the matrix phenotype of cultured MFC. These findings suggest that the use of normal and low oxygen tension during MFC expansion and subsequent neo

  9. Evaluation of native hyaline cartilage and repair tissue after two cartilage repair surgery techniques with 23Na MR imaging at 7 T: initial experience.

    Science.gov (United States)

    Zbýň, S; Stelzeneder, D; Welsch, G H; Negrin, L L; Juras, V; Mayerhoefer, M E; Szomolanyi, P; Bogner, W; Domayer, S E; Weber, M; Trattnig, S

    2012-08-01

    To compare the sodium normalized mean signal intensity (NMSI) values between patients after bone marrow stimulation (BMS) and matrix-associated autologous chondrocyte transplantation (MACT) cartilage repair procedures. Nine BMS and nine MACT patients were included. Each BMS patient was matched with one MACT patient according to age [BMS 36.7 ± 10.7 (mean ± standard deviation) years; MACT 36.9 ± 10.0 years], postoperative interval (BMS 33.5 ± 25.3 months; MACT 33.2 ± 25.7 months), and defect location. All magnetic resonance imaging (MRI) measurements were performed on a 7 T system. Proton images served for morphological evaluation of repair tissue using the magnetic resonance observation of cartilage repair tissue (MOCART) scoring system. Sodium NMSI values in the repair area and morphologically normal cartilage were calculated. Clinical outcome was assessed right after MRI. Analysis of covariance, t-tests, and Pearson correlation coefficients were evaluated. Sodium NMSI was significantly lower in BMS (P = 0.004) and MACT (P = 0.006) repair tissue, compared to reference cartilage. Sodium NMSI was not different between the reference cartilage in MACT and BMS patients (P = 0.664), however it was significantly higher in MACT than in BMS repair tissue (P = 0.028). Better clinical outcome was observed in BMS than in MACT patients. There was no difference between MOCART scores for MACT and BMS patients (P = 0.915). We did not observe any significant correlation between MOCART score and sodium repair tissue NMSI (r = -0.001; P = 0.996). Our results suggest higher glycosaminoglycan (GAG) content, and therefore, repair tissue of better quality in MACT than in BMS patients. Sodium imaging might be beneficial in non-invasive evaluation of cartilage repair surgery efficacy. Copyright © 2012 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  10. BIOMECHANICS AND HISTOLOGICAL ANALYSIS IN RABBIT FLEXOR TENDONS REPAIRED USING THREE SUTURE TECHNIQUES (FOUR AND SIX STRANDS) WITH EARLY ACTIVE MOBILIZATION.

    Science.gov (United States)

    Severo, Antônio Lourenço; Arenhart, Rodrigo; Silveira, Daniela; Ávila, Aluísio Otávio Vargas; Berral, Francisco José; Lemos, Marcelo Barreto; Piluski, Paulo César Faiad; Lech, Osvandré Luís Canfield; Fukushima, Walter Yoshinori

    2012-01-01

    Analyzing suture time, biomechanics (deformity between the stumps) and the histology of three groups of tendinous surgical repair: Brazil-2 (4-strands) which the end knot (core) is located outside the tendon, Indiana (4-strands) and Tsai (6-strands) with sutures technique which the end knot (core) is inner of the tendon, associated with early active mobilization. The right calcaneal tendons (plantar flexor of the hind paw) of 36 rabbits of the New Zealand breed (Oryctolagus cuniculus) were used in the analysis. This sample presents similar size to human flexor tendon that has approximately 4.5 mm (varying from 2mm). The selected sample showed the same mass (2.5 to 3kg) and were male or female adults (from 8 ½ months). For the flexor tendons of the hind paws, sterile and driven techniques were used in accordance to the Committee on Animal Research and Ethics (CETEA) of the University of the State of Santa Catarina (UDESC), municipality of Lages, in Brazil (protocol # 1.33.09). In the biomechanical analysis (deformity) carried out between tendinous stumps, there was no statistically significant difference (p>0.01). There was no statistical difference in relation to surgical time in all three suture techniques with a mean of 6.0 minutes for Tsai (6- strands), 5.7 minutes for Indiana (4-strands) and 5.6 minutes for Brazil (4-strands) (p>0.01). With the early active mobility, there was qualitative and quantitative evidence of thickening of collagen in 38.9% on the 15(th) day and in 66.7% on the 30(th) day, making the biological tissue stronger and more resistant (p=0.095). This study demonstrated that there was no histological difference between the results achieved with an inside or outside end knot with respect to the repaired tendon and the number of strands did not affect healing, vascularization or sliding of the tendon in the osteofibrous tunnel, which are associated with early active mobility, with the repair techniques applied.

  11. BIOMECHANICS AND HISTOLOGICAL ANALYSIS IN RABBIT FLEXOR TENDONS REPAIRED USING THREE SUTURE TECHNIQUES (FOUR AND SIX STRANDS) WITH EARLY ACTIVE MOBILIZATION

    Science.gov (United States)

    Severo, Antônio Lourenço; Arenhart, Rodrigo; Silveira, Daniela; Ávila, Aluísio Otávio Vargas; Berral, Francisco José; Lemos, Marcelo Barreto; Piluski, Paulo César Faiad; Lech, Osvandré Luís Canfield; Fukushima, Walter Yoshinori

    2015-01-01

    Objective: Analyzing suture time, biomechanics (deformity between the stumps) and the histology of three groups of tendinous surgical repair: Brazil-2 (4-strands) which the end knot (core) is located outside the tendon, Indiana (4-strands) and Tsai (6-strands) with sutures technique which the end knot (core) is inner of the tendon, associated with early active mobilization. Methods: The right calcaneal tendons (plantar flexor of the hind paw) of 36 rabbits of the New Zealand breed (Oryctolagus cuniculus) were used in the analysis. This sample presents similar size to human flexor tendon that has approximately 4.5 mm (varying from 2mm). The selected sample showed the same mass (2.5 to 3kg) and were male or female adults (from 8 ½ months). For the flexor tendons of the hind paws, sterile and driven techniques were used in accordance to the Committee on Animal Research and Ethics (CETEA) of the University of the State of Santa Catarina (UDESC), municipality of Lages, in Brazil (protocol # 1.33.09). Results: In the biomechanical analysis (deformity) carried out between tendinous stumps, there was no statistically significant difference (p>0.01). There was no statistical difference in relation to surgical time in all three suture techniques with a mean of 6.0 minutes for Tsai (6- strands), 5.7 minutes for Indiana (4-strands) and 5.6 minutes for Brazil (4-strands) (p>0.01). With the early active mobility, there was qualitative and quantitative evidence of thickening of collagen in 38.9% on the 15th day and in 66.7% on the 30th day, making the biological tissue stronger and more resistant (p=0.095). Conclusion: This study demonstrated that there was no histological difference between the results achieved with an inside or outside end knot with respect to the repaired tendon and the number of strands did not affect healing, vascularization or sliding of the tendon in the osteofibrous tunnel, which are associated with early active mobility, with the repair techniques

  12. Very long-term results (more than 20 years) of valve repair with carpentier's techniques in nonrheumatic mitral valve insufficiency.

    Science.gov (United States)

    Braunberger, E; Deloche, A; Berrebi, A; Abdallah, F; Celestin, J A; Meimoun, P; Chatellier, G; Chauvaud, S; Fabiani, J N; Carpentier, A

    2001-09-18

    Mitral valve repair is considered the gold standard in surgery of degenerative mitral valve insufficiency (MVI), but the long-term results (>20 years) are unknown. We reviewed the first 162 consecutive patients who underwent mitral valve repair between 1970 and 1984 for MVI due to nonrheumatic disease. The cause of MVI was degenerative in 146 patients (90%) and bacterial endocarditis in 16 patients (10%). MVI was isolated or, in 18 cases, associated with tricuspid insufficiency. The mean age of the 162 patients (104 men and 58 women) was 56+/-10 years (age range 22 to 77 years). New York Heart Association functional class was I, II, III, and IV in 2%, 39%, 52%, and 7% of patients, respectively. The mean cardiothoracic ratio was 0.58+/-0.07 (0.4 to 0.8), and 72 (45%) patients had atrial fibrillation. Valve analysis showed that the main mechanism of MVI was type II Carpentier's functional classification in 152 patients. The leaflet prolapse involved the posterior leaflet in 93 patients, the anterior leaflet in 28 patients, and both leaflets in 31 patients. Surgical technique included a Carpentier's ring annuloplasty in all cases, a valve resection in 126 patients, and shortening or transposition of chordae in 49 patients. During the first postoperative month, there were 3 deaths (1.9%) and 3 reoperations (2 valve replacements and 1 repeat repair [1.9%]). Six patients were lost to follow-up. The remaining 151 patients with mitral valve repair were followed during a median of 17 years (range 1 to 29 years; 2273 patient-years). The 20-year Kaplan-Meier survival rate was 48% (95% CI 40% to 57%), which is similar to the survival rate for a normal population with the same age structure. The 20-year rates were 19.3% (95% CI 11% to 27%) for cardiac death and 26% (95% CI 17% to 35%) for cardiac morbidity/mortality (including death from a cardiac cause, stroke, and reoperation). During the 20 years of follow-up, 7 patients were underwent surgery at 3, 7, 7, 8, 8, 10, or 12

  13. Intraosseous repair of the inferior alveolar nerve in rats: an experimental model.

    Science.gov (United States)

    Curtis, N J; Trickett, R I; Owen, E; Lanzetta, M

    1998-08-01

    A reliable method of exposure of the inferior alveolar nerve in Wistar rats has been developed, to allow intraosseous repair with two microsurgical techniques under halothane inhalational anaesthesia. The microsuturing technique involves anastomosis with 10-0 nylon sutures; a laser-weld technique uses an albumin-based solder containing indocyanine green, plus an infrared (810 nm wavelength) diode laser Seven animals had left inferior alveolar nerve repairs performed with the microsuture and laser-weld techniques. Controls were provided by unoperated nerves in the repaired cases. Histochemical analysis was performed utilizing neuron counts and horseradish peroxidase tracer (HRP) uptake in the mandibular division of the trigeminal ganglion, following sacrifice and staining of frozen sections with cresyl violet and diaminobenzidene. The results of this analysis showed similar mean neuron counts and mean HRP uptake by neurons for the unoperated controls and both microsuture and laser-weld groups. This new technique of intraosseous exposure of the inferior alveolar nerve in rats is described. It allows reliable and reproducible microsurgical repairs using both microsuture and laser-weld techniques.

  14. Problems in repair-welding of duplex-treated tool steels

    Directory of Open Access Journals (Sweden)

    T. Muhič

    2009-01-01

    Full Text Available The present paper addresses problems in laser welding of die-cast tools used for aluminum pressure die-castings and plastic moulds. To extend life cycle of tools various surface improvements are used. These surface improvements significantly reduce weldability of the material. This paper presents development of defects in repair welding of duplex-treated tool steel. The procedure is aimed at reduction of defects by the newly developed repair laser welding techniques. Effects of different repair welding process parameters and techniques are considered. A microstructural analysis is conducted to detect defect formation and reveal the best laser welding method for duplex-treated tools.

  15. Imaging and management of complications of open surgical repair of abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Nayeemuddin, M.; Pherwani, A.D.; Asquith, J.R.

    2012-01-01

    Open repair is still considered the reference standard for long-term repair of abdominal aortic aneurysms (AAA). In contrast to endovascular aneurysm repair (EVAR), patients with open surgical repair of AAA are not routinely followed up with imaging. Although complications following EVAR are widely recognized and routinely identified on follow-up imaging, complications also do occur following open surgical repair. With frequent use of multi-slice computed tomography (CT) angiography (CTA) in vascular patients, there is now improved recognition of the potential complications following open surgical repair. Many of these complications are increasingly being managed using endovascular techniques. The aim of this review is to illustrate a variety of potential complications that may occur following open surgical repair and to demonstrate their management using both surgical and endovascular techniques.

  16. In Vitro Comparison of Two Barbed Suture Configurations for Flexor Tendon Repair.

    Science.gov (United States)

    Engel, Jamie L; Gabra, Joseph N; Esterle, Andrew R; Lanzinger, William D; Elias, John J

    2017-12-01

    Purpose  The current study compares the strength of a previously studied technique for flexor tendon repair with barbed sutures to an experimental approach that aligns all the barbs to oppose distraction. Methods  Twelve flexor tendons from cadaveric specimens were mechanically tested following repair of simulated zone II tendon injuries. Two repair techniques utilizing barbed sutures were studied: the Marrero-Amadeo four-core barbed suture approach and the experimental configuration with all barbs on four cores opposing distraction. Maximum applied load at failure, that is, ultimate load, and 2-mm gap force were compared between the two repair techniques, both as raw values and after normalization to cross-sectional area of the intact tendon. Statistical testing was performed using t -tests and Mann-Whitney U -tests, where appropriate, with a significance level of 0.05. Results  The ultimate loads, raw (58.2 N) and normalized (4.8 N/mm 2 ), were significantly larger for the Marrero-Amadeo repair than the proposed experimental approach (35.6 N and 2.7 N/mm 2 ; p  barbs to oppose distraction does not improve strength of the repaired tendon. The Marrero-Amadeo technique was found to have superior strength for use in traumatic zone II flexor tendon injuries.

  17. Biomechanical evaluation of a single-row versus double-row repair for complete subscapularis tears.

    Science.gov (United States)

    Wellmann, Mathias; Wiebringhaus, Philipp; Lodde, Ina; Waizy, Hazibullah; Becher, Christoph; Raschke, Michael J; Petersen, Wolf

    2009-12-01

    The purpose of the study was to compare a single-row repair and a double-row repair technique for the specific characteristics of a complete subscapularis lesion. Ten pairs of human cadaveric shoulder human shoulder specimens were tested for stiffness and ultimate tensile strength of the intact tendons in a load to failure protocol. After a complete subscapularis tear was provoked, the specimens were assigned to two treatment groups: single-row repair (1) and a double-row repair using a "suture bridge" technique (2). After repair cyclic loading a subsequent load to failure protocol was performed to determine the ultimate tensile load, the stiffness and the elongation behaviour of the reconstructions. The intact subscapularis tendons had a mean stiffness of 115 N/mm and a mean ultimate load of 720 N. The predominant failure mode of the intact tendons was a tear at the humeral insertion site (65%). The double-row technique restored 48% of the ultimate load of the intact tendons (332 N), while the single-row technique revealed a significantly lower ultimate load of 244 N (P = 0.001). In terms of the stiffness, the double-row technique showed a mean stiffness of 81 N/mm which is significantly higher compared to the stiffness of the single-row repairs of 55 N/mm (P = 0.001). The double-row technique has been shown to be stronger and stiffer when compared to a conventional single-row repair. Therefore, this technique is recommended from a biomechanical point of view irrespectively if performed by an open or arthroscopic approach.

  18. Surgical repair of mid-body proximal sesamoid bone fractures in 25 horses.

    Science.gov (United States)

    Busschers, Evita; Richardson, Dean W; Hogan, Patricia M; Leitch, Midge

    2008-12-01

    To describe the characteristics of unilateral mid-body proximal sesamoid bone (PSB) fractures, to determine factors associated with the outcome of horses after surgical repair, and to describe a technique for arthroscopically assisted screw fixation in lag fashion. Retrospective case series. Horses (n=25) with unilateral mid-body PSB fracture. Medical records (1996-2006), radiographs, and arthroscopic videos of horses with surgically repaired unilateral mid-body PSB fractures were reviewed. Retrieved data included signalment, affected limb and PSB, fracture characteristics, and surgical technique. Outcome was established by radiographic assessment of healing and race records; categorical data were analyzed using Fisher's Exact test. Medial forelimb PSBs were most commonly affected (80%). Surgical technique and degree of reduction were significantly associated with outcome; 44% of horses with screw repair and none of the horses with wire fixation raced (P=.047). Factors that may have influenced this outcome were differences in fracture reduction (improved reduction in 22% wire repairs and 88% screw repairs, P=.002) and use of external coaptation (22% wire repair and 88% lag screw repair, P=.002). None of the horses with unimproved reduction raced after surgery. Only 28% of horses with mid-body PSB fractures raced after surgery. Compared with wire fixation, screw fixation in lag fashion resulted in good reduction and is seemingly a superior repair technique. For mid-body PSB fractures, arthroscopically assisted screw fixation in lag fashion and external coaptation for anesthesia recovery and initial support provides the best likelihood of return to athletic use.

  19. Development of Guidelines for In-Situ Repair of SLS-Class Composite Flight Hardware

    Science.gov (United States)

    Weber, Thomas P., Jr.; Cox, Sarah B.

    2018-01-01

    The purpose of composite repair development at KSC (John F. Kennedy Space Center) is to provide support to the CTE (Composite Technology for Exploration) project. This is a multi-space center effort with the goal of developing bonded joint technology for SLS (Space Launch System) -scale composite hardware. At KSC, effective and efficient repair processes need to be developed to allow for any potential damage to composite components during transport or launch preparation. The focus of the composite repair development internship during the spring of 2018 was on the documentation of repair processes and requirements for process controls based on techniques developed through hands-on work with composite test panels. Three composite test panels were fabricated for the purpose of repair and surface preparation testing. The first panel included a bonded doubler and was fabricated to be damaged and repaired. The second and third panels were both fabricated to be cut into lap-shear samples to test the strength of bond of different surface preparation techniques. Additionally, jointed composite test panels were impacted at MSFC (Marshall Space Flight Center) and analyzed for damage patterns. The observations after the impact tests guided the repair procedure at KSC to focus on three repair methods. With a finalized repair plan in place, future work will include the strength testing of different surface preparation techniques, demonstration of repair methods, and repair of jointed composite test panels being impacted at MSFC.

  20. Biomechanical Comparison of Single- Versus Double-Row Capsulolabral Repair for Shoulder Instability: A Review.

    Science.gov (United States)

    Yousif, Matthew John; Bicos, James

    2017-12-01

    The glenohumeral joint is the most commonly dislocated joint in the body. Failure rates of capsulolabral repair have been reported to be approximately 8%. Recent focus has been on restoration of the capsulolabral complex by a double-row capsulolabral repair technique in an effort to decrease redislocation rates after arthroscopic capsulolabral repair. To present a review of the biomechanical literature comparing single- versus double-row capsulolabral repairs and discuss the previous case series of double-row fixation. Narrative review. A simple review of the literature was performed by PubMed search. Only biomechanical studies comparing single- versus double-row capsulolabral repair were included for review. Only those case series and descriptive techniques with clinical results for double-row repair were included in the discussion. Biomechanical comparisons evaluating the native footprint of the labrum demonstrated significantly superior restoration of the footprint through double-row capsulolabral repair compared with single-row repair. Biomechanical comparisons of contact pressure at the repair interface, fracture displacement in bony Bankart lesion, load to failure, and decreased external rotation (suggestive of increased load to failure) were also significantly in favor of double- versus single-row repair. Recent descriptive techniques and case series of double-row fixation have demonstrated good clinical outcomes; however, no comparative clinical studies between single- and double-row repair have assessed functional outcomes. The superiority of double-row capsulolabral repair versus single-row repair remains uncertain because comparative studies assessing clinical outcomes have yet to be performed.

  1. Relationship of DNA repair and chromosome aberrations to potentially lethal damage repair in X-irradiated mammalian cells

    International Nuclear Information System (INIS)

    Fornace, A.J. Jr.; Nagasawa, H.; Little, J.B.

    1980-01-01

    By the alkaline elution technique, the repair of x-ray-induced DNA single strand breaks and DNA-protein cross-links was investigated in stationary phase, contact-inhibited mouse cells. During the first hour of repair, approximately 90% of x-ray induced single strand breaks were rejoined whereas most of the remaining breaks were rejoined more slowly during the next 5 h. The number of residual non-rejoined single strand breaks was approximately proportional to the x-ray dose at early repair times. DNA-protein cross-links were removed at a slower rate - T 1/2 approximately 10 to 12 h. Cells were subcultured at low density at various times after irradiation and scored for colony survival, and chromosome aberrations in the first mitosis after sub-culture. Both cell lethality and the frequency of chromosome aberrations decreased during the first several hours of repair, reaching a minimum level by 6 h; this decrease correlated temporally with the repair of the slowly rejoining DNA strand breaks. The possible relationship of DNA repair to changes in survival and chromosome aberrations is discussed

  2. Prosthetic Mesh Repair for Incarcerated Inguinal Hernia

    Directory of Open Access Journals (Sweden)

    Cihad Tatar

    2016-08-01

    Full Text Available Background: Incarcerated inguinal hernia is a commonly encountered urgent surgical condition, and tension-free repair is a well-established method for the treatment of noncomplicated cases. However, due to the risk of prosthetic material-related infections, the use of mesh in the repair of strangulated or incarcerated hernia has often been subject to debate. Recent studies have demonstrated that biomaterials represent suitable materials for performing urgent hernia repair. Certain studies recommend mesh repair only for cases where no bowel resection is required; other studies, however, recommend mesh repair for patients requiring bowel resection as well. Aim: The aim of this study was to compare the outcomes of different surgical techniques performed for strangulated hernia, and to evaluate the effect of mesh use on postoperative complications. Study Design: Retrospective cross-sectional study. Methods: This retrospective study was performed with 151 patients who had been admitted to our hospital’s emergency department to undergo surgery for a diagnosis of incarcerated inguinal hernia. The patients were divided into two groups based on the applied surgical technique. Group 1 consisted of 112 patients treated with mesh-based repair techniques, while Group 2 consisted of 39 patients treated with tissue repair techniques. Patients in Group 1 were further divided into two sub-groups: one consisting of patients undergoing bowel resection (Group 3, and the other consisting of patients not undergoing bowel resection (Group 4. Results: In Group 1, it was observed that eight (7.14% of the patients had wound infections, while two (1.78% had hematomas, four (3.57% had seromas, and one (0.89% had relapse. In Group 2, one (2.56% of the patients had a wound infection, while three (7.69% had hematomas, one (2.56% had seroma, and none had relapses. There were no statistically significant differences between the two groups with respect to wound infection

  3. Laser-activated solid protein bands for peripheral nerve repair: an vivo study.

    Science.gov (United States)

    Lauto, A; Trickett, R; Malik, R; Dawes, J M; Owen, E R

    1997-01-01

    Severed tibial nerves in rats were repaired using a novel technique, utilizing a semiconductor diode-laser-activated protein solder applied longitudinally across the join. Welding was produced by selective laser denaturation of solid solder bands containing the dye indocyanine green. An in vivo study, using 48 adult male Wistar rats, compared conventional microsuture-repaired tibial nerves with laser solder-repaired nerves. Nerve repairs were characterised immediately after surgery and after 3 months. Successful regeneration with average compound muscle action potentials of 2.5 +/- 0.5 mV and 2.7 +/- 0.3 mV (mean and standard deviation) was demonstrated for the laser-soldered nerves and the sutured nerves, respectively. Histopathology confirmed comparable regeneration of axons in laser- and suture-operated nerves. The laser-based nerve repair technique was easier and faster than microsuture repair, minimising manipulation damage to the nerve.

  4. Early anterior cruciate ligament reconstruction can save meniscus without any complications

    Directory of Open Access Journals (Sweden)

    Chang-Ik Hur

    2017-01-01

    Conclusions: Early ACL reconstruction had excellent clinical results and stability as good as delayed reconstruction without the problem of knee motion, muscle power, and postural control. Moreover, early reconstruction showed the high possibility of meniscal repair. Therefore, early ACL reconstruction should be recommended.

  5. Evaluation of different techniques for repair of co-arctation of aorta

    Directory of Open Access Journals (Sweden)

    Karimi AA

    1998-08-01

    Full Text Available This study is on different surgical techniques for repair of Co-arctation of aort and their effect for correction of systemic hypertension and lower extremity hypotension. In addition to these, the clinical and paraclinical data were noticed. 50 pt were operated in "SHARIATI" hospital during 1370-1377 with diagnosis of Co-arctation of aorta (30 men, mean age 19.4 years, 20 women, mean age 16.6 years. In addition to older age of our patients which results in more post-op sequela, there was suprrisingly a long-lag between onset of symptoms, diagnosis and operation (mean 4.36 years. 62% of Co-arctation were juxtaductal and the remainder were non-classical forms. 52% of our patients had co-existing cardiac disease which were very high in comparison with other studies (12%. This is due to older age of our patients and more valvular heart diseases. Among complicated cases of co-arctation, 71.9% were in men and 28.1% in women and this difference is due to high incidence of bicuspid aortic valve in men. The mean angiographic gradient were 57.5 mmHg which increases with age. CXR was abnormal in 91.7% and ECG in 74.2% of patients. The different applied surgical techniques include ee-A=26%, TIG=40%, TBG=18%, DPR=14%, FSCR=2%. There is no significant difference regarding post-op complications, BP in post-op period, and increase in pedal pulses, except in TBG group which HTN was more common. Two early deaths occurred which were in DRP group.

  6. Short frontal plane fractures involving the dorsoproximal articular surface of the proximal phalanx: Description of the injury and a technique for repair.

    Science.gov (United States)

    Wright, I M; Minshall, G J

    2018-01-01

    Chip fractures of the dorsoproximal articular margin of the proximal phalanx are common injuries in racehorses. Large fractures can extend distal to the joint capsule insertion and have been described as dorsal frontal fractures. To report the location and morphology of short frontal plane fractures involving the dorsoproximal articular surface of the proximal phalanx and describe a technique for repair under arthroscopic and radiographic guidance. Single centre retrospective case study. Case records of horses with frontal plane fractures restricted to the dorsoproximal epiphysis and metaphysis of the proximal phalanx referred to Newmarket Equine Hospital were retrieved, images reviewed and lesion morphology described. A technique for repair and the results obtained are reported. A total of 22 fractures in 21 horses commencing at the proximal articular surface exited the dorsal cortex of the proximal phalanx distal to the metacarpophalangeal/metatarsophalangeal joint capsule in 17 hind- and five forelimbs. All were in Thoroughbred racehorses. In 16 cases these were acute racing or training injuries; 20 fractures were medial, one lateral and one was midline. All were repaired with a single lag screw using arthroscopic and radiographically determined landmarks. A total of 16 horses raced after surgery with performance data similar to their preinjury levels. The study demonstrates substantial morphological similarities between individual lesions supporting a common pathophysiology, but does not identify precise causation. There are no cases managed differently that might permit assessment of the comparative efficacy of the treatment described. Short frontal plane fractures involving the dorsoproximal margin of the proximal phalanx that exit the bone distal to the metacarpophalangeal/metatarsophalangeal joint capsule have substantial morphological similarities, are amenable to minimally invasive repair and carry a good prognosis for return to training and racing.

  7. A new incision for unilateral cleft lip repair developed using animated simulation of repair on computer

    Directory of Open Access Journals (Sweden)

    Sahay A

    2007-01-01

    Full Text Available Background: Unilateral cleft lip repair continues to leave behind some amount of dissatisfaction, as a scope for further improvement is always felt. Most surgeons do not like to deviate from the standard Millard′s/ triangular techniques, or their minor modifications, as no one likes to experiment on the face for fear of unfavourable outcomes. The computer can be utilized as a useful tool in the analysis and planning of surgery and new methods can be developed and attempted subsequently with greater confidence. Aim: We decided to see if an improved lip repair could be developed with the use of computers. Materials and Methods: Analysis of previous lip repairs was done to determine where an improvement was required. Movement of tissues, by simulating an ideal repair, using image warping software, on digital images of cleft lip was studied in animation sequences. A repair which could reproduce these movements was planned. A new incision emerged, which had combined the principles of Millard′s and Randall / Tennyson repairs, with additional features. The new method was performed on 30 cases. Conclusions: The results were encouraging as the shortcomings of these methods were minimized, and the advantages maximized.

  8. Inguinal hernia repair in the Amsterdam region 1994-1996.

    Science.gov (United States)

    Schoots, I G; van Dijkman, B; Butzelaar, R M; van Geldere, D; Simons, M P

    2001-03-01

    In the Netherlands, approximately 30,000 inguinal hernia repairs are performed yearly. At least 15% are for recurrence. New procedures are being introduced creating discussion on which technique is the best. Currently it is not possible to choose on evidence alone because of the long follow-up that is needed. In 1996 an inventory was taken of all inguinal hernia repairs that were performed in the Amsterdam region (9 hospitals). These results were compared with the results from a similar study performed in 1994. Major changes in treatment strategy were noted. The Bassini repair was replaced by Shouldice and Lichtenstein techniques. There was a significant increase in the use of prostheses for both primary and recurrent inguinal hernias. There was no significant decrease in the percentage of operations performed for recurrent hernia from 19.5% to 16.8%. However, there was a significant decrease in operations performed for early recurrences (5.1%-3.4%) (p = 0.05). These results suggest that the Shouldice and Lichtenstein repairs may be superior to the Bassini repair in terms of early hernia recurrence.

  9. Use of hydroxyurea in the measurement of DNA repair by the BND cellulose method

    International Nuclear Information System (INIS)

    Irwin, J.; Strauss, B.

    1980-01-01

    Hydroxyurea inhibition is a convenient method of suppressing replicative DNA synthesis for DNA excision-repair measurement by the BND cellulose technique. Nonetheless, hydroxyurea can introduce artefacts by direct reaction with repair-inducing compounds and by long-term inhibition of the overall repair process. A simple technique of overcoming these problems is described. Cells are reacted with repair-inducing compounds in the absence of hydroxyurea, the cells are washed free of inducer, hydroxyurea is added to 2 mM, and after a short period to establish replication inhibition, 3 H dThd is added and repair measured over a one-hour incubation period

  10. Weld Repair of Thin Aluminum Sheet

    Science.gov (United States)

    Beuyukian, C. S.; Mitchell, M. J.

    1986-01-01

    Weld repairing of thin aluminum sheets now possible, using niobium shield and copper heat sinks. Refractory niobium shield protects aluminum adjacent to hole, while copper heat sinks help conduct heat away from repair site. Technique limits tungsten/inert-gas (TIG) welding bombardment zone to melt area, leaving surrounding areas around weld unaffected. Used successfully to repair aluminum cold plates on Space Shuttle, Commercial applications, especially in sealing fractures, dents, and holes in thin aluminum face sheets or clad brazing sheet in cold plates, heat exchangers, coolers, and Solar panels. While particularly suited to thin aluminum sheet, this process also used in thicker aluminum material to prevent surface damage near weld area.

  11. Biomechanical characteristics of single-row repair in comparison to double-row repair with consideration of the suture configuration and suture material

    OpenAIRE

    Baums, M. H.; Buchhorn, G. H.; Spahn, G.; Poppendieck, B.; Schultz, W.; Klinger, H.-M.

    2008-01-01

    The aim of the study was to evaluate the time zero mechanical properties of single- versus double-row configuration for rotator cuff repair in an animal model with consideration of the stitch technique and suture material. Thirty-two fresh-frozen sheep shoulders were randomly assigned to four repair groups: suture anchor single-row repair coupled with (1) braided, nonabsorbable polyester suture sized USP No. 2 (SRAE) or (2) braided polyblend polyethylene suture sized No. 2 (SRAH). The double-...

  12. Arthroscopic anterior talofibular ligament repair for chronic ankle instability with a suture anchor technique.

    Science.gov (United States)

    Kim, Eung Soo; Lee, Kyung Tai; Park, Jun Sic; Lee, Young Koo

    2011-04-11

    The goal of this study was to retrospectively evaluate the clinical outcomes of arthroscopic repair for chronic ankle instability using a bioabsorbable anchor with 2 sutures. We evaluated the results of 28 ankles treated with arthroscopic anterior talofibular ligament repair using bioabsorbable anchors with a FiberWire and TigerWire suture (Arthrex, Inc, Naples, Florida) placed on the fibula from March 2008 to January 2009. Average follow-up was 15.9 months (range, 13-25 months). Patients were evaluated using the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot ankle score and stress radiographs. Mean AOFAS hindfoot ankle score was 92.48 ± 6.14 at last follow-up compared to the mean preoperative score of 60.78 ± 16.38 (P=.041). Mean postoperative anterior draw test score difference between 2 ankles was 0.61 ± 0.75 compared to the mean preoperative score difference of 3.59 ± 0.68 (P=.00). There was a 14% complication rate, including 3 cases of portal site irritation and 1 case of superficial infection. Stress radiographs revealed 3 cases of anterior displacement >3 mm compared to the other side. All patients returned to their previous activity level.Arthroscopic ligament reconstruction for chronic lateral ankle instability using suture anchors is effective in returning patients to their preinjury function levels. Good clinical results were obtained with some minor complications. This minimally invasive technique is a reasonable alternative to other open surgical procedures for chronic ankle instability. Copyright 2011, SLACK Incorporated.

  13. Saturation of DNA repair in mammalian cells

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, F E; Setlow, R B

    1979-01-01

    Excision repair seems to reach a plateau in normal human cells at a 254 nm dose near 20 J/m/sup 2/. We measured excision repair in normal human fibroblasts up to 80 J/m/sup 2/. The four techniques used (unscheduled DNA synthesis, photolysis of BrdUrd incorporated during repair, loss of sites sensitive to a UV endonuclease from Micrococcus luteus, and loss of pyrimidine dimers from DNA) showed little difference between the two doses. Moreover, the loss of endonuclease sites in 24h following two 20 J/m/sup 2/ doses separated by 24h was similar to the loss observed following one dose. Hence, we concluded that the observed plateau in excision repair is real and does not represent some inhibitory process at high doses but a true saturation of one of the rate limiting steps in repair.

  14. Acute and chronic response of meniscal fibrocartilage to holmium:YAG laser irradiation

    Science.gov (United States)

    Horan, Patrick J.; Popovic, Neven A.; Islinger, Richard B.; Kuklo, Timothy R.; Dick, Edward J.

    1997-05-01

    The acute and chronic (10 week) histological effects of the holmium:YAG laser during partial meniscectomy in an in vivo rabbit model were investigated. Twenty-four adult male New Zealand rabbits underwent bilateral parapatellar medial knee arthrotomies. In the right knee, a partial medial meniscectomy was done through the avascular zone using a standard surgical blade. In the left knee, an anatomically similar partial medial meniscectomy was performed using a Ho:YAG laser (Coherent, USA). This study indicates that the laser creates two zones of damage in the meniscal fibrocartilage and that the zone of thermal change may act as a barrier to healing. The zone of thermal change which is eventually debrided was thought at the time of surgery to be viable. In the laser cut menisci, the synovium appears to have greater inflammation early and to be equivalent with the scalpel cut after three weeks. At all time periods there appeared more cellular damage in the laser specimens.

  15. Primary unilateral cleft lip repair.

    Science.gov (United States)

    Adenwalla, H S; Narayanan, P V

    2009-10-01

    The unilateral cleft lip is a complex deformity. Surgical correction has evolved from a straight repair through triangular and quadrilateral repairs to the Rotation Advancement Technique of Millard. The latter is the technique followed at our centre for all unilateral cleft lip patients. We operate on these at five to six months of age, do not use pre-surgical orthodontics, and follow a protocol to produce a notch-free vermillion. This is easy to follow even for trainees. We also perform closed alar dissection and extensive primary septoplasty in all these patients. This has improved the overall result and has no long-term deleterious effect on the growth of the nose or of the maxilla. Other refinements have been used for prevention of a high-riding nostril, and correction of the vestibular web.

  16. A biomechanical comparison of single and double-row fixation in arthroscopic rotator cuff repair.

    Science.gov (United States)

    Smith, Christopher D; Alexander, Susan; Hill, Adam M; Huijsmans, Pol E; Bull, Anthony M J; Amis, Andrew A; De Beer, Joe F; Wallace, Andrew L

    2006-11-01

    The optimal method for arthroscopic rotator cuff repair is not yet known. The hypothesis of the present study was that a double-row repair would demonstrate superior static and cyclic mechanical behavior when compared with a single-row repair. The specific aims were to measure gap formation at the bone-tendon interface under static creep loading and the ultimate strength and mode of failure of both methods of repair under cyclic loading. A standardized tear of the supraspinatus tendon was created in sixteen fresh cadaveric shoulders. Arthroscopic rotator cuff repairs were performed with use of either a double-row technique (eight specimens) or a single-row technique (eight specimens) with nonabsorbable sutures that were double-loaded on a titanium suture anchor. The repairs were loaded statically for one hour, and the gap formation was measured. Cyclic loading to failure was then performed. Gap formation during static loading was significantly greater in the single-row group than in the double-row group (mean and standard deviation, 5.0 +/- 1.2 mm compared with 3.8 +/- 1.4 mm; p row repairs failed at a mean of 320 +/- 96.9 N whereas the single-row repairs failed at a mean of 224 +/- 147.9 N (p = 0.058). Three single-row repairs and three double-row repairs failed as a result of suture cut-through. Four single-row repairs and one double-row repair failed as a result of anchor or suture failure. The remaining five repairs did not fail, and a midsubstance tear of the tendon occurred. Although more technically demanding, the double-row technique demonstrates superior resistance to gap formation under static loading as compared with the single-row technique. A double-row reconstruction of the supraspinatus tendon insertion may provide a more reliable construct than a single-row repair and could be used as an alternative to open reconstruction for the treatment of isolated tears.

  17. Pseudo-arthrosis repair of a posterior cruciate ligament avulsion fracture

    OpenAIRE

    Hoogervorst, Paul; Gardeniers, J. W. M.; Moret-Wever, S.; van Kampen, A.

    2010-01-01

    A pseudo-arthrosis repair of a 4-year-old bony avulsion fracture of the PCL using a minimally invasive technique, screw fixation, and bone grafting is reported. The case presented seems to be rather unique due to the fragment size and the approach for pseudo-arthrosis repair. There was a good functional result following minimally invasive pseudo-arthrosis repair of a posterior cruciate ligament avulsion fracture. There are no previous reports of similar pseudo-arthrosis repairs, and other aut...

  18. Bridging suture makes consistent and secure fixation in double-row rotator cuff repair.

    Science.gov (United States)

    Fukuhara, Tetsutaro; Mihata, Teruhisa; Jun, Bong Jae; Neo, Masashi

    2017-09-01

    Inconsistent tension distribution may decrease the biomechanical properties of the rotator cuff tendon after double-row repair, resulting in repair failure. The purpose of this study was to compare the tension distribution along the repaired rotator cuff tendon among three double-row repair techniques. In each of 42 fresh-frozen porcine shoulders, a simulated infraspinatus tendon tear was repaired by using 1 of 3 double-row techniques: (1) conventional double-row repair (no bridging suture); (2) transosseous-equivalent repair (bridging suture alone); and (3) compression double-row repair (which combined conventional double-row and bridging sutures). Each specimen underwent cyclic testing at a simulated shoulder abduction angle of 0° or 40° on a material-testing machine. Gap formation and tendon strain were measured during the 1st and 30th cycles. To evaluate tension distribution after cuff repair, difference in gap and tendon strain between the superior and inferior fixations was compared among three double-row techniques. At an abduction angle of 0°, gap formation after either transosseous-equivalent or compression double-row repair was significantly less than that after conventional double-row repair (p row repair (p = 0.01) at 0° abduction had significantly less difference in gap formation between the superior and inferior fixations than did conventional double-row repair. After the 30th cycle, the difference in longitudinal strain between the superior and inferior fixations at 0° abduction was significantly less with compression double-row repair (2.7% ± 2.4%) than with conventional double-row repair (8.6% ± 5.5%, p = 0.03). Bridging sutures facilitate consistent and secure fixation in double-row rotator cuff repairs, suggesting that bridging sutures may be beneficial for distributing tension equally among all sutures during double-row repair of rotator cuff tears. Copyright © 2017 The Japanese Orthopaedic Association. Published by Elsevier B

  19. Semiconductors detectors: basics principals, fabrication and repair

    International Nuclear Information System (INIS)

    Souza Coelho, L.F. de.

    1982-05-01

    The fabrication and repairing techniques of semiconductor detectors, are described. These methods are shown in the way they are applied by the semiconductor detector laboratory of the KFA-Julich, where they have been developed during the last 15 years. The history of the semiconductor detectors is presented here, being also described the detector fabrication experiences inside Brazil. The key problems of manufacturing are raised. In order to understand the fabrication and repairing techniques the working principles of these detectors, are described. The cases in which worked during the stay in the KFA-Julich, particularly the fabrication of a plane Ge (Li) detector, with side entry, and the repair of a coaxial Ge (Li) is described. The vanguard problems being researched in Julich are also described. Finally it is discussed a timetable for the semiconductor detector laboratory of the UFRJ, which laboratory is in the mounting stage now. (Author) [pt

  20. Meniscal tear evaluation. Comparison of a conventional spin-echo proton density sequence with a fast spin-echo sequence utilizing a 512x358 matrix size

    International Nuclear Information System (INIS)

    Hopper, M.A.; Robinson, P.; Grainger, A.J.

    2011-01-01

    Aim: To determine the sensitivities, specificities, and receiver-operating characteristics (ROCs) for sagittal conventional spin-echo proton density (SE-PD) and fast spin-echo proton density (FSE-PD) sequences in the diagnosis of meniscal tears when compared to arthroscopic findings utilizing increased FSE matrix acquisition size. Method and materials: Magnetic resonance imaging (MRI) studies of 97 knees (194 menisci) were independently and prospectively interpreted by two experienced musculoskeletal radiologists over four separate readings at least 3 weeks apart. Readings 1 and 2 included images in all three planes in accordance with the standard protocol with either a SE or FSE sagittal PD, at readings 3 and 4 just the SE or FSE sagittal PD sequences were reported. The FSE sequence was acquired with an increased matrix size, compared to the SE sequence, to provide increased resolution. Menisci were graded for the presence of a tear and statistical analysis to calculate sensitivity and specificity was performed comparing to arthroscopy as the reference standard. ROC analysis for the diagnosis of meniscal tears on the SE and FSE sagittal sequences was also evaluated. Reader concordance for the SE and FSE sequences was calculated. Results: Sixty-seven tears were noted at arthroscopy; 60 were detected on SE and 56 on FSE. The sensitivity and specificity for SE was 90 and 90%, and for FSE was 84 and 94%, respectively, with no significant difference. ROC analysis showed no significant difference between the two sequences and kappa values demonstrated a higher level of reader agreement for the FSE than for the SE reading. Conclusion: Use of a FSE sagittal PD sequence with an increased matrix size provides comparable performance to conventional SE sagittal PD when evaluating meniscal disease with a modern system. The present study indicates an increased level of concordance between readers for the FSE sagittal sequence compared to the conventional SE.

  1. Meniscal tear evaluation. Comparison of a conventional spin-echo proton density sequence with a fast spin-echo sequence utilizing a 512x358 matrix size

    Energy Technology Data Exchange (ETDEWEB)

    Hopper, M.A.; Robinson, P. [Leeds Teaching Hospitals NHS Trust, Leeds (United Kingdom); Grainger, A.J., E-mail: andrew.grainger@leedsth.nhs.u [Leeds Teaching Hospitals NHS Trust, Leeds (United Kingdom)

    2011-04-15

    Aim: To determine the sensitivities, specificities, and receiver-operating characteristics (ROCs) for sagittal conventional spin-echo proton density (SE-PD) and fast spin-echo proton density (FSE-PD) sequences in the diagnosis of meniscal tears when compared to arthroscopic findings utilizing increased FSE matrix acquisition size. Method and materials: Magnetic resonance imaging (MRI) studies of 97 knees (194 menisci) were independently and prospectively interpreted by two experienced musculoskeletal radiologists over four separate readings at least 3 weeks apart. Readings 1 and 2 included images in all three planes in accordance with the standard protocol with either a SE or FSE sagittal PD, at readings 3 and 4 just the SE or FSE sagittal PD sequences were reported. The FSE sequence was acquired with an increased matrix size, compared to the SE sequence, to provide increased resolution. Menisci were graded for the presence of a tear and statistical analysis to calculate sensitivity and specificity was performed comparing to arthroscopy as the reference standard. ROC analysis for the diagnosis of meniscal tears on the SE and FSE sagittal sequences was also evaluated. Reader concordance for the SE and FSE sequences was calculated. Results: Sixty-seven tears were noted at arthroscopy; 60 were detected on SE and 56 on FSE. The sensitivity and specificity for SE was 90 and 90%, and for FSE was 84 and 94%, respectively, with no significant difference. ROC analysis showed no significant difference between the two sequences and kappa values demonstrated a higher level of reader agreement for the FSE than for the SE reading. Conclusion: Use of a FSE sagittal PD sequence with an increased matrix size provides comparable performance to conventional SE sagittal PD when evaluating meniscal disease with a modern system. The present study indicates an increased level of concordance between readers for the FSE sagittal sequence compared to the conventional SE.

  2. CT arthrography and virtual arthroscopy in the diagnosis of the anterior cruciate ligament and meniscal abnormalities of the knee joint

    International Nuclear Information System (INIS)

    Lee, Whal; Chung, Jin-Wook; Kang, Heung-Sik; Hong, Sung-Hwan; Choi, Ja-Young; Kim, Ho-Sung; Kim, Seok-Jung; Kim, Hyung-Ho

    2004-01-01

    To determine the diagnostic accuracy of CT arthrography and virtual arthroscopy in the diagnosis of anterior cruciate ligament and meniscus pathology. Thirty-eight consecutive patients sho underwent CT arthrography and arthroscopy of the knee were included in this study. The ages of the patients ranged from 19 to 52 years and all of the patients were male. Sagittal, coronal, transverse and oblique coronal multiplanar reconstruction images were reformatted from CT arthrography. Virtual arthroscopy was performed from 6 standard views using a volume rendering technique. Three radiologists analyzed the MPR images and two orthopedic surgeons analyzed the virtual arthroscopic images. The sensitivity and specificity of CT arthrography for the diagnosis of anterior cruciate ligament abnormalities were 87.5%-100% and 93.3%-96.7%, respectively and those for meniscus abnormalities were 91.7%-100% and 98.1%, respectively. The sensitivity and specificity of virtual arthroscopy for the diagnosis of anterior cruciate ligament abnormalities were 87.5% and 83.3%-90%, respectively, and those for meniscus abnormalities were 83.3%-87.5% and 96.1-98.1%, respectively. CT arthrography and virtual arthroscopy showed good diagnostic accuracy for anterior cruciate ligament and meniscal abnormalities

  3. The Biomechanical Role of Scaffolds in Augmented Rotator Cuff Tendon Repairs

    Science.gov (United States)

    2012-01-01

    The biomechanical role of scaffolds in augmented rotator cuff tendon repairs Amit Aurora, D Enga,b, Jesse A. McCarron, MDc, Antonie J. van den Bogert...used for rotator cuff repair augmentation; however, the appropriate scaffold material properties and/or surgical application techniques for achieving...The model predicts that the biomechanical performance of a rotator cuff repair can be modestly increased by augmenting the repair with a scaffold that

  4. Using technique vibration diagnostics for assessing the quality of power transmission line supports repairs

    Directory of Open Access Journals (Sweden)

    Cherpakov Aleksander

    2017-01-01

    Full Text Available The considered method for assessing the quality of the repair work to restore the rack supports of transmission lines is based on the method of vibration diagnostics. Power transmission line supports with a symmetrical destruction of the protective layer of concrete in the ground in violation of the construction section were chosen as an object. Finite element modelling package Ansys was used in assessing the quality of repair work. The example of evaluating the quality of repair using the relative adhesion defective area design criteria in the analysis of natural vibration frequencies is given.

  5. Biomechanical evaluation of knotless anatomical double-layer double-row rotator cuff repair: a comparative ex vivo study.

    Science.gov (United States)

    Hepp, Pierre; Osterhoff, Georg; Engel, Thomas; Marquass, Bastian; Klink, Thomas; Josten, Christoph

    2009-07-01

    The layered configuration of the rotator cuff tendon is not taken into account in classic rotator cuff tendon repair techniques. The mechanical properties of (1) the classic double-row technique, (2) a double-layer double-row (DLDR) technique in simple suture configuration, and (3) a DLDR technique in mattress suture configuration are significantly different. Controlled laboratory study. Twenty-four sheep shoulders were assigned to 3 repair groups of full-thickness infraspinatus tears: group 1, traditional double-row repair; group 2, DLDR anchor repair with simple suture configuration; and group 3, DLDR knotless repair with mattress suture configuration. After ultrasound evaluation of the repair, each specimen was cyclically loaded with 10 to 100 N for 50 cycles. Each specimen was then loaded to failure at a rate of 1 mm/s. There were no statistically significant differences among the 3 testing groups for the mean footprint area. The cyclic loading test revealed no significant difference among the 3 groups with regard to elongation. For the load-to-failure test, groups 2 and 3 showed no differences in ultimate tensile load when compared with group 1. However, when compared to group 2, group 3 was found to have significantly higher values regarding ultimate load, ultimate elongation, and energy absorbed. The DLDR fixation techniques may provide strength of initial repair comparable with that of commonly used double-row techniques. When compared with the knotless technique with mattress sutures, simple suture configuration of DLDR repair may be too weak. Knotless DLDR rotator cuff repair may (1) restore the footprint by the use of double-row principles and (2) enable restoration of the shape and profile. Double-layer double-row fixation in mattress suture configuration has initial fixation strength comparable with that of the classic double-row fixation and so may potentially improve functional results of rotator cuff repair.

  6. Dynamic compression of human and ovine meniscal tissue compared with a potential thermoplastic elastomer hydrogel replacement.

    Science.gov (United States)

    Fischenich, Kristine M; Boncella, Katie; Lewis, Jackson T; Bailey, Travis S; Haut Donahue, Tammy L

    2017-10-01

    Understanding how human meniscal tissue responds to loading regimes mimetic of daily life as well as how it compares to larger animal models is critical in the development of a functionally accurate synthetic surrogate. Seven human and eight ovine cadaveric meniscal specimens were regionally sectioned into cylinders 5 mm in diameter and 3 mm thick along with 10 polystyrene-b-polyethylene oxide block copolymer-based thermoplastic elastomer (TPE) hydrogels. Samples were compressed to 12% strain at 1 Hz for 5000 cycles, unloaded for 24 h, and then retested. No differences were found within each group between test one and test two. Human and ovine tissue exhibited no regional dependency (p Human samples relaxed quicker than ovine tissue or the TPE hydrogel with modulus values at cycle 50 not significantly different from cycle 5000. Ovine menisci were found to be similar to human menisci in relaxation profile but had significantly higher modulus values (3.44 MPa instantaneous and 0.61 MPa after 5000 cycles compared with 1.97 and 0.11 MPa found for human tissue) and significantly different power law fit coefficients. The TPE hydrogel had an initial modulus of 0.58 MPa and experienced less than a 20% total relaxation over the 5000. Significant differences in the magnitude of compressive modulus between human and ovine menisci were observed, however the relaxation profiles were similar. Although statistically different than the native tissues, modulus values of the TPE hydrogel material were similar to those of the human and ovine menisci, making it a material worth further investigation for use as a synthetic replacement. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 2722-2728, 2017. © 2017 Wiley Periodicals, Inc.

  7. Non-parametric estimation of the availability in a general repairable system

    International Nuclear Information System (INIS)

    Gamiz, M.L.; Roman, Y.

    2008-01-01

    This work deals with repairable systems with unknown failure and repair time distributions. We focus on the estimation of the instantaneous availability, that is, the probability that the system is functioning at a given time, which we consider as the most significant measure for evaluating the effectiveness of a repairable system. The estimation of the availability function is not, in general, an easy task, i.e., analytical techniques are difficult to apply. We propose a smooth estimation of the availability based on kernel estimator of the cumulative distribution functions (CDF) of the failure and repair times, for which the bandwidth parameters are obtained by bootstrap procedures. The consistency properties of the availability estimator are established by using techniques based on the Laplace transform

  8. Non-parametric estimation of the availability in a general repairable system

    Energy Technology Data Exchange (ETDEWEB)

    Gamiz, M.L. [Departamento de Estadistica e I.O., Facultad de Ciencias, Universidad de Granada, Granada 18071 (Spain)], E-mail: mgamiz@ugr.es; Roman, Y. [Departamento de Estadistica e I.O., Facultad de Ciencias, Universidad de Granada, Granada 18071 (Spain)

    2008-08-15

    This work deals with repairable systems with unknown failure and repair time distributions. We focus on the estimation of the instantaneous availability, that is, the probability that the system is functioning at a given time, which we consider as the most significant measure for evaluating the effectiveness of a repairable system. The estimation of the availability function is not, in general, an easy task, i.e., analytical techniques are difficult to apply. We propose a smooth estimation of the availability based on kernel estimator of the cumulative distribution functions (CDF) of the failure and repair times, for which the bandwidth parameters are obtained by bootstrap procedures. The consistency properties of the availability estimator are established by using techniques based on the Laplace transform.

  9. Penatalaksanaan Repair Palatoplasty dengan Teknik Furlow Double Opposing Z Plasty

    Directory of Open Access Journals (Sweden)

    Pingky Krisna Arindra

    2015-06-01

    metode Furlow double opposing z plasty dengan kombinasi insisi lateral, dan didapatkan hasil menutupnya celah di palatum mole sampai dengan uvula. Telah dilakukan operasi repair palatoplasi dengan metode Furlow double opposing z plasty. Teknik ini dilakukan untuk menghindari insisi yang terlalu luas dikarenakan terdapatnya jaringan fibrous yang tebal pada mukosa palatum pasca operasi sebelumnya. Tujuan studi kasus adalah untuk mengetahui kemampuan teknik Furlow Double Opposing Z Plasty sebagai prosedur repair palatoplasty.   Repair Palatoplasty Management with Furlow Double Opposing Z Plasty Technique. Cases of cleft lip and palate are one of the deformity disorders that often occur. There are variety of clinical appearance ranging from incomplete to complete cases. Clinical appearance with different width requires proper surgical technique. Patients with cleft lip and palate had undergone surgical intervention, so that they needed surgical correction to repair the result or failure of the previous surgery. A Four year old boy complain there was cleft on the soft palate. The patient was diagnosed with labiognatopalatoscisis. The patient had undergone two stages of cleft lip surgery and twice of cleft palate surgery with pushback method and repair with z plasty, however the result was unsatisfactory. Further, the patient underwent repair palatoplasty surgery with Furlow double opposing z plasty method combined with lateral relaxing insicion. The result in the post surgery was the closure of cleft soft palate up to uvula. Repair palataplasty surgery has been done with Furlow double opposing z plasty method. This technique could avoid extended incision due to thick fibrous tissue on the palatum mucosa as the result of serial previous surgery. The aim of this case case study is to determine the technical capabilities of Furlow Double Opposing Z Plasty as palatoplasty repair procedure.

  10. Posterior horn lateral meniscal tears simulating meniscofemoral ligament attachment in the setting of ACL tear: MRI findings

    International Nuclear Information System (INIS)

    Park, Lawrence S.; Jacobson, Jon A.; Jamadar, David A.; Caoili, Elaine; Kalume-Brigido, Monica; Wojtys, Edward

    2007-01-01

    We have noted apparent far lateral meniscal attachment of the meniscofemoral ligament (MFL) with an anterior cruciate ligament (ACL) tear. This study evaluates MFL attachment and association with posterior horn lateral meniscus (PHLM) tear. Nine months of knee arthroscopy reports were reviewed to classify the PHLM and ACL as torn or normal. After excluding those with prior knee surgery, MR images were reviewed by two radiologists to determine the number of images lateral to PCL, which showed the ligaments of Humphrey and Wrisberg visible as structures separate from the PHLM. Any patient with abnormal PHLM surface signal not continuous with the MFL was excluded. MRI findings were compared with arthroscopy using Student's t test and Fisher's exact test. Of the 54 participants, 5 had PHLM tears and 49 were normal. Twenty-one had ACL tears; all those with an PHLM tear had an ACL tear. The ligament of Humphrey inserted on average 0.9 consecutive images lateral to the PCL without an PHLM tear and 4.7 with an PHLM tear; the ligament of Wrisberg inserted on average 3.0 consecutive images without an PHLM tear and 4.5 with an PHLM tear (slice thickness/gap = 3 mm/0.5 mm). There was a significant association between PHLM tear and number of images (p = 0.0028), and between ACL tear and this type of PHLM tear (p = 0.0064). Apparent far lateral meniscal extension of a meniscofemoral ligament (greater than or equal to four images lateral to the PCL) should be considered as a possible PHLM tear, especially in the setting of an ACL tear. (orig.)

  11. A combined technique using a muscular flap and endobronchial stent to repair complex broncho-oesophageal fistulae supported by ECMO.

    Science.gov (United States)

    Baste, Jean-Marc; Haddad, Laura; Philouze, Guillaume

    2018-02-01

    Certain broncho-oesophageal fistulae require surgical repair. Herein, we describe an innovative surgical technique combining intercostal flap and endobronchial stenting. Two patients, each with a with complex broncho-oesophageal fistula 2 years after radio-chemotherapy, were hospitalised for severe respiratory infection and extension of the fistula despite previous endoscopic treatment. The first patient presented with respiratory distress (ARDS). She had emergency surgery under extra corporeal membrane oxygenation: oesophagectomy and reconstruction of the left bronchus by a vascularised intercostal flap. Stenting was performed on day 10, due to persistence of the fistula. At 3 months the bronchus was healed, but the patient died of cerebral bleeding. For the second patient, repair was proposed before severe ARDS with the same surgical and ventilatory strategy and a stent was preventively inserted after surgery. After 3 months, the stent was removed and the left bronchus was healed. Complex post-radiotherapy broncho-oesophageal fistulae should be treated surgically before respiratory complications arise, by combining reconstruction with a vascularised flap and transient stenting.

  12. Laparoscopic repair of high rectovaginal fistula: Is it technically feasible?

    Directory of Open Access Journals (Sweden)

    Parthasarathi Ramakrishnan

    2005-10-01

    Full Text Available Abstract Background Rectovaginal fistula (RVF is an epithelium-lined communication between the rectum and vagina. Most RVFs are acquired, the most common cause being obstetric trauma. Most of the high RVFs are repaired by conventional open surgery. Laparoscopic repair of RVF is rare and so far only one report is available in the literature. Methods We present a case of high RVF repaired by laparoscopy. 56-year-old female who had a high RVF following laparoscopic assisted vaginal hysterectomy was successfully operated laparoscopically. Here we describe the operative technique and briefly review the literature. Results The postoperative period of the patient was uneventful and after a follow up of 6 months no recurrence was found. Conclusion Laparoscopic repair of high RVF is feasible in selected patients but would require proper identification of tissue planes and good laparoscopic suturing technique.

  13. Lingual mucosal graft two-stage Bracka technique for redo hypospadias repair

    Directory of Open Access Journals (Sweden)

    Ahmed Sakr

    2017-09-01

    Conclusion: Lingual mucosa is a reliable and versatile graft material in the armamentarium of two-stage Bracka hypospadias repair with the merits of easy harvesting and minor donor-site complications.

  14. Laparoscopic repair for vesicouterine fistulae

    Directory of Open Access Journals (Sweden)

    Rafael A. Maioli

    2015-10-01

    . Discussion: Laparoscopy has advantages over open surgery in that it is associated with less pain, shorter length of hospital stay, better cosmesis, quicker recovery, and equal efficacy. Although cases of VUF are rarely noted, the laparoscopic skill obtained through other urological procedures suggest, that laparoscopic repair may be the procedure of choice for such cases (2. The reported operative time for the laparoscopic repair of VUF in the literature varies between 140 and 220 min (3. However, laparoscopic techniques should be considered as a mode of abdominal access and should not influence the method of surgical repair. Surgical success should depend on the adherence to good technique rather than the approach. Hence, this method appears to be a viable alternative for surgeons experienced with laparoscopic suturing techniques. Conclusion: Laparoscopic repair appears to be a viable alternative for surgeons experienced with laparoscopic suturing techniques.

  15. Reversed double PCL sign: unusual location of a meniscal fragment of the knee observed by MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Niitsu, M.; Itai, Y. [Dept. of Radiology, Inst. of Clinical Medicine, Univ. of Tsukuba, Ibaraki (Japan); Ikeda, K. [Inst. of Clinical Medicine, Univ. of Tsukuba, Ibaraki (Japan)

    2003-12-01

    A 36-year-old woman with tears of the anterior cruciate ligament and medial meniscus received a meniscectomy. The MR images obtained prior to the partial meniscectomy showed a bucket-handle meniscal tear with centrally displaced fragment lying anterior to the posterior cruciate ligament (PCL), representing a ''double PCL sign''; however, after the meniscectomy, MR images demonstrated a fragment in the space posterior to the PCL where no structure is generally recognized except for the ligament of wrisberg. This article reports a ''reversed'' double PCL sign, caused by inadequate surgical clearance of a bucket-handle tear of the medial meniscus. (orig.)

  16. Primary unilateral cleft lip repair

    Directory of Open Access Journals (Sweden)

    Adenwalla H

    2009-10-01

    Full Text Available The unilateral cleft lip is a complex deformity. Surgical correction has evolved from a straight repair through triangular and quadrilateral repairs to the Rotation Advancement Technique of Millard. The latter is the technique followed at our centre for all unilateral cleft lip patients. We operate on these at five to six months of age, do not use pre-surgical orthodontics, and follow a protocol to produce a notch-free vermillion. This is easy to follow even for trainees. We also perform closed alar dissection and extensive primary septoplasty in all these patients. This has improved the overall result and has no long-term deleterious effect on the growth of the nose or of the maxilla. Other refinements have been used for prevention of a high-riding nostril, and correction of the vestibular web.

  17. Assessment of Concrete Repair Techniques for Radiologically-Contaminated Tank Farm Pump and Valve Pits

    International Nuclear Information System (INIS)

    MINTEER, D.J.

    2000-01-01

    As part of the scope of Project W-314, ''Tank Farm Restoration and Safe Operations,'' the condition of pump and valve pit walls and floors is being assessed, and repairs made as needed, to support upgrading the infrastructure necessary to safely transfer tank waste for treatment. Flaws in the surfaces of the pits (e.g., concrete crack/faults, protective coating deterioration) must be repaired to ensure containment integrity and to facilitate future decontamination of the pits. This engineering study presents a cost/risk/benefit evaluation of concrete and protective coating repair methods in pump and valve pits using various manual and remote tool systems

  18. A novel silk suture-assisted laparoscopic technique for the repair of a gastrocolic fistula in a pediatric patient

    Directory of Open Access Journals (Sweden)

    Seher Mughal

    2016-10-01

    Full Text Available Percutaneous placement of gastrostomy was first described in 1980. Since then it has become widely used in pediatric surgery throughout the world. Inherent in the technique is the possibility of inadvertent damage to adjacent anatomical structures, most commonly the transverse colon. Management previously had involved laparotomy and correction of the gastrocolic fistula. Here we describe a novel laparoscopic approach to the repair of a gastrocolic fistula following percutaneous gastrostomy, avoiding the morbidity of laparotomy in an immunocompromised patient with a rotund abdomen secondary to steroid usage.

  19. Laparoscopic-assisted repair of Morgagni–Larrey hernia by anterior ...

    African Journals Online (AJOL)

    Various techniques have been described to repair Morgagni–Larrey hernia. There is still concerns on the sufficiency of a simple laparoscopic anterior abdominal wall fixation. We aim to report of two children undergoingthe laparoscopic-assisted anterior abdominal wall repair for Morgagni–Larrey hernia, and to discuss this ...

  20. Excellent healing rates and patient satisfaction after arthroscopic repair of medium to large rotator cuff tears with a single-row technique augmented with bone marrow vents.

    Science.gov (United States)

    Dierckman, Brian D; Ni, Jake J; Karzel, Ronald P; Getelman, Mark H

    2018-01-01

    This study evaluated the repair integrity and patient clinical outcomes following arthroscopic rotator cuff repair of medium to large rotator cuff tears using a single-row technique consisting of medially based, triple-loaded anchors augmented with bone marrow vents in the rotator cuff footprint lateral to the repair. This is a retrospective study of 52 patients (53 shoulders) comprising 36 males and 16 females with a median age of 62 (range 44-82) with more than 24-month follow-up, tears between 2 and 4 cm in the anterior-posterior dimension and utilizing triple-loaded anchors. Mann-Whitney test compared Western Ontario Rotator Cuff (WORC) outcome scores between patients with healed and re-torn cuff repairs. Multivariate logistic regression analysed association of variables with healing status and WORC score. Cuff integrity was assessed on MRI, read by a musculoskeletal fellowship-trained radiologist. Magnetic resonance imaging (MRI) demonstrated an intact repair in 48 of 53 shoulders (91%). The overall median WORC score was 95.7 (range 27.6-100.0). A significant difference in WORC scores were seen between patients with healed repairs 96.7 (range 56.7-100.0) compared with a re-tear 64.6 (27.6-73.8), p rotator cuff tears using a triple-loaded single-row repair augmented with bone marrow vents resulted in a 91% healing rate by MRI and excellent patient reported clinical outcomes comparable to similar reported results in the literature. IV.