WorldWideScience

Sample records for medical diagnostic equipment

  1. The introduction of compulsory compliance testing of medical diagnostic x-ray equipment in Western Australia

    International Nuclear Information System (INIS)

    Rafferty, M. W.; Jacob, C. S.

    1995-01-01

    Performance testing of medical diagnostic X-ray equipment can reveal equipment faults which, while not always clinically detectable, may contribute to reduced image quality and unnecessary radiation exposure of both patients and staff. Routine testing of such equipment is highly desirable to identify such faults and allows them to be rectified. The Radiological council of Western Australia is moving towards requiring compulsory compliance testing of all (new and existing) medical diagnostic X-ray equipment that all new mobile radiographic and new mammographic X-ray equipment be issued with a compliance test certificate as a prerequisite for registration. Workbooks which provide details of the tests required and recommended test methods have been prepared for medical radiographic (mobile and fixed), fluoroscopic and mammographic X-ray equipment. It is intended that future workbooks include details of the tests and methods for dental and computed tomography X-ray units. The workbooks are not limited to the compliance testing of items as specified in the Regulations, but include tests for other items such as film processing, darkrooms and image quality (for fluoroscopic equipment). Many of the workbook tests could be used within a regular quality assurance program for diagnostic X-ray equipment. Persons who conduct such compliance tests will need to be licensed and have all test certificates endorsed by a qualified expert. Suitable training and assessment of compliance testers will be required. Notification of such tests (including non-compliant items and corrective actions taken) will be required by the Radiological Council as a condition of equipment registration. 9 refs

  2. Analysis of licensed South African diagnostic imaging equipment ...

    African Journals Online (AJOL)

    Analysis of licensed South African diagnostic imaging equipment. ... Pan African Medical Journal ... Introduction: Objective: To conduct an analysis of all registered South Africa (SA) diagnostic radiology equipment, assess the number of equipment units per capita by imaging modality, and compare SA figures with published ...

  3. Diagnostic x-ray equipment compliance and facility survey. Recommended procedures for equipment and facility testing

    International Nuclear Information System (INIS)

    1994-01-01

    The Radiation Protection Bureau has set out guidelines for the testing of diagnostic x-ray equipment and facilities. This guide provides information for the x-ray inspector, test engineer, technologist, medical physicist and any other person responsible for verifying the regulatory compliance or safety of diagnostic x-ray equipment and facilities. Diagnostic x-radiation is an essential part of present day medical practice. The largest contributor of irradiation to the general population comes from diagnostic x-radiation. Although individual irradiations are usually small, there is a concern of possible excess cancer risk when large populations are irradiated. Unnecessary irradiations to patients from radiological procedures can be significantly reduced with little or no decrease in the value of medical diagnostic information. This can be achieved by using well designed x-ray equipment which is installed, used and maintained by trained personnel, and by the adoption of standardized procedures. In general, when patient surface dose is reduced, there is a corresponding decrease in dose to x-ray equipment operators and other health care personnel. 2 tabs., 4 figs

  4. Diagnostic x-ray equipment compliance and facility survey. Recommended procedures for equipment and facility testing

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    The Radiation Protection Bureau has set out guidelines for the testing of diagnostic x-ray equipment and facilities. This guide provides information for the x-ray inspector, test engineer, technologist, medical physicist and any other person responsible for verifying the regulatory compliance or safety of diagnostic x-ray equipment and facilities. Diagnostic x-radiation is an essential part of present day medical practice. The largest contributor of irradiation to the general population comes from diagnostic x-radiation. Although individual irradiations are usually small, there is a concern of possible excess cancer risk when large populations are irradiated. Unnecessary irradiations to patients from radiological procedures can be significantly reduced with little or no decrease in the value of medical diagnostic information. This can be achieved by using well designed x-ray equipment which is installed, used and maintained by trained personnel, and by the adoption of standardized procedures. In general, when patient surface dose is reduced, there is a corresponding decrease in dose to x-ray equipment operators and other health care personnel. 2 tabs., 4 figs.

  5. Diagnostic imaging and radiation therapy equipment

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1990-05-01

    This is the third edition of CSA Standard C22.2 No. 114 (now CAN/CSA-C22.2 No. 114), which is one of a series of standards issued by the Canadian Standards Association under Part II of the Canadian Electrical Code. This edition marks an important shift towards harmonization of Canadian requirements with those of the European community and the United States. Also important to this edition is the expansion of its scope to include the complete range of diagnostic imaging and radiation therapy equipment, rather than solely radiation-emitting equipment. In so doing, equipment previously addressed by CSA Standard C22.2 No. 125, Electromedical Equipment, specifically lasers for medical applications and diagnostic ultrasound units, is now dealt with in the new edition. By virtue of this expanded scope, many of the technical requirements in the electromedical equipment standard have been introduced to the new edition, thereby bringing CSA Standard C22.2 No. 114 up to date. 14 tabs., 16 figs.

  6. Diagnostic imaging and radiation therapy equipment

    International Nuclear Information System (INIS)

    1990-05-01

    This is the third edition of CSA Standard C22.2 No. 114 (now CAN/CSA-C22.2 No. 114), which is one of a series of standards issued by the Canadian Standards Association under Part II of the Canadian Electrical Code. This edition marks an important shift towards harmonization of Canadian requirements with those of the European community and the United States. Also important to this edition is the expansion of its scope to include the complete range of diagnostic imaging and radiation therapy equipment, rather than solely radiation-emitting equipment. In so doing, equipment previously addressed by CSA Standard C22.2 No. 125, Electromedical Equipment, specifically lasers for medical applications and diagnostic ultrasound units, is now dealt with in the new edition. By virtue of this expanded scope, many of the technical requirements in the electromedical equipment standard have been introduced to the new edition, thereby bringing CSA Standard C22.2 No. 114 up to date. 14 tabs., 16 figs

  7. A compliance testing program for diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Hutchinson, D.E.; Cobb, B.J.; Jacob, C.S.

    1999-01-01

    Compliance testing is nominally that part of a quality assurance program dealing with those aspects of X-ray equipment performance that are subject to radiation control legislation. Quality assurance programs for medical X-ray equipment should be an integral part of the quality culture in health care. However while major hospitals and individual medical centers may implement such programs with some diligence, much X-ray equipment can remain unappraised unless there is a comprehensive regulatory inspection program or some form of compulsion on the equipment owner to implement a testing program. Since the late 1950s all X-ray equipment in the State of Western Australia has been inspected by authorized officers acting on behalf of the Radiological Council, the regulatory authority responsible for administration of the State's Radiation Safety Act. However, economic constraints, coupled with increasing X-ray equipment numbers and a geographically large State have significantly affected the inspection rate. Data available from inspections demonstrate that regular compliance and performance checks are essential in order to ensure proper performance and to minimize unnecessary patient and operator dose. To ensure that diagnostic X-ray equipment complies with accepted standards and performance criteria, the regulatory authority introduced a compulsory compliance testing program for all medical, dental and chiropractic diagnostic X-ray equipment effective from 1 January 1997

  8. Constancy check of beam quality in conventional diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Costa, Alessandro M.; Badin, Romulo S.; Leite, Marina S.; Caldas, Linda V.E.

    2008-01-01

    A tandem ionization chamber was developed for quality control programs of X-ray equipment used in conventional radiography and mammography. A methodology for the use of the tandem chamber in the constancy check of diagnostic X-ray beam qualities was established. The application at a medical X-ray imaging facility of this established methodology is presented. The use of the tandem chamber in the constancy check of diagnostic X-ray beam qualities is a useful method to control the performance of the X-ray equipment

  9. Medical Issues: Equipment

    Science.gov (United States)

    ... Information Packets Equipment Pool Living With SMA Medical Issues Palliative Breathing Orthopedics Nutrition Equipment Daily Life At ... curesma.org > support & care > living with sma > medical issues > equipment Equipment Individuals with SMA often require a ...

  10. Medical equipment management

    CERN Document Server

    Willson, Keith; Tabakov, Slavik

    2013-01-01

    Know What to Expect When Managing Medical Equipment and Healthcare Technology in Your Organization As medical technology in clinical care becomes more complex, clinical professionals and support staff must know how to keep patients safe and equipment working in the clinical environment. Accessible to all healthcare professionals and managers, Medical Equipment Management presents an integrated approach to managing medical equipment in healthcare organizations. The book explains the underlying principles and requirements and raises awareness of what needs to be done and what questions to ask. I

  11. Problems of radiation protection at medical use of radiation equipment

    International Nuclear Information System (INIS)

    Larwin, K.

    1979-01-01

    For medical use of radiation equipment man is not only operator, but also object (patient). The question, if or how much it is necessary to expose the patient, is a medical problem and therefore not to be discussed here. For the user of medical equipments we have often special conditions. For many diagnostic applications the physician has to stay in the application room in contact with the patient. As a typical example for the problems of radiation protection there is discussed the situation on a well known fluoroscopic unit for lung and stomach examinations. (author)

  12. Quality control of diagnostic x-ray equipment and film processing

    International Nuclear Information System (INIS)

    1993-01-01

    According to the section 40 of the Radiation Act (592/92), the licensee is required in Finland to make the arrangements to control the function of the radiation equipment and related facilities used for medical procedures. The guide explains how quality control can be organized for diagnostic x-ray equipment. It also gives recommendations for constancy tests for conventional x-ray radiographic and fluoroscopic equipment and for film processing. The recommendations are based on the publications and statements of the International Committee for Radiation Protection (ICRP) and standardization organizations. The intention is that the operators of x-ray equipment or the maintenance personnel are able to perform the quality control tests presented in the guide

  13. Preliminary survey on the distribution of medical equipment and frequency of diagnostic and therapeutic procedures in Brazil: a contribution to the UNSCEAR report

    International Nuclear Information System (INIS)

    Biazotto, Bruna; Taboza de Oliveira, Alexandre; Baptista de Freitas, Marcelo

    2008-01-01

    Information about Brazil published in the UNSCEAR 2000 report are still scarce when compared to others countries. In this study, a survey on the distribution of medical equipment (X-ray generators, ultrasound, CT and MRI scanners, nuclear medicine equipment and teletherapy and brachytherapy units) and frequency of diagnostic and therapeutic procedures at the various Brazilian States was carried out. The overall information was obtained from a national database supported by the Brazilian Ministry of Health through the Computer Science Department of the National Health System (SUS - Sistema Unico de Saude). The distribution of equipment and the annual frequency of each type of procedure were analyzed considering the five geographical regions that form the country and their respective population. Temporal and regional trends in the annual frequency of procedures for 2000-2007 were also summarized in this study. National annual frequencies for the total of all medical X-ray examinations (259.0 examinations per 1000 population) were evaluated. Some examples can be given from chest, mammography and CT examinations: 67.4, 30.2 and 7.2 per 1000 population, respectively. In addition, annual frequencies for other modalities of diagnostic imaging have also been estimated: 61.5, 1.6 and 1.4 per 1000 population for ultrasound, nuclear medicine and MRI procedures, respectively. A total of 38.7 therapeutic procedures per 1000 population (teletherapy and brachytherapy) are annually performed in the country. The health services localized in Brazil comprised a total number of 253.1 diagnostic imaging equipment per million population, without considering dental X-ray. Amongst them, X-ray equipment used in common radiological examinations (chest, skull, spine, etc.) stands for 39% (97.7 per million). As expected, a significant decrease in the offer of equipment is observed when technologically more sophisticated equipment is concerned: magnetic resonance (3.5 per million), gamma

  14. TU-G-213-02: IEC Subcommittee 62B (Diagnostic Imaging Equipment): Recent and Active Projects

    International Nuclear Information System (INIS)

    Supanich, M.

    2015-01-01

    The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists

  15. TU-G-213-02: IEC Subcommittee 62B (Diagnostic Imaging Equipment): Recent and Active Projects

    Energy Technology Data Exchange (ETDEWEB)

    Supanich, M. [Rush University Medical Center (United States)

    2015-06-15

    The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists.

  16. Defects in medical X-ray equipment

    International Nuclear Information System (INIS)

    Eder, H.; Wahl, H.; Troeger, W.

    1979-01-01

    A careful estimate of the effects on the genetically significant radiation load shows that it is in the same order of magnitude as the increase in the skin dose area product. This is to say that of the genetically significant radiation dose of about 500 mJ/kg (50 mrem) per year and person due to medical X-ray diagnostics, about 75 mJ/kg (7.5 mrem) are due to serious defects in X-ray equipment. (orig.) [de

  17. Compliance testing of medical diagnostic x-ray equipment: three years experience of a public hospital in western Australia

    International Nuclear Information System (INIS)

    Tuchyna, T.; Jacob, C.S.

    2000-01-01

    Full text: A formal compliance testing program which began on 1 January 1997 called for all medical and diagnostic x-ray equipment to be tested according to protocols established by the Western Australian Radiological Council. This work describes the impact of the legislation three years post implementation on a major teaching Hospital with 45 x-ray tubes located throughout 37 rooms. Testing is performed prior to scheduled service by licensed compliance testers according to test methods specified in the Western Australian Compliance Testing Workbook, 1997. A dedicated non-invasive x-ray beam analyser is instrumental in accurately determining radiation output parameters of the generator and x-ray tube. Assessment of compliance is determined by a Qualified Expert. Repair and re-testing of non-compliant items is coordinated with service personnel. Notices of non-compliance were received for approximately 60% of the equipment in the Hospital following the equipment' first annual test. Reasons and seriousness of failure varied according to equipment category, test category, equipment use and age. The majority of non-compliance issues were resolved within 90 days. At the end of the third year of testing, approximately 75% of the x-ray units tested met the compliance criteria. The main reasons for non-compliance were found to be design limitations associated with old technology and the current radiation legislation that makes it difficult for older equipment to meet the stringent criteria. The number and categories of failure did not significantly decrease in the second or third years of testing. Exemptions from compliance criteria have been sought for two units on the basis of age and design. Units unable to meet the criteria following several repair attempts or where the cost of repair was deemed not justified, were decommissioned. Formal testing of medical x-ray equipment has demonstrated various non-compliance issues that did not significantly improve during the

  18. Course of radiological protection and safety in the medical diagnostic with X-rays

    International Nuclear Information System (INIS)

    Dominguez A, C.E.

    1997-01-01

    The obtention of images of human body to the medical diagnostic is one of the more old and generalized applications for X-ray. Therefore the design and performance of equipment and installations as well as the operation procedures must be oriented toward safety with the purpose to guarantee this radiological practice will bring a net positive benefit to the society. Given that in Mexico only exists the standardization related to source and equipment generators of ionizing radiation in the industrial area and medical therapy, but not so to the medical diagnostic area it is the purpose of this work to present those standards related with this application branch. Also it is presented the preparation of a manual for the course named Formation of teachers in radiological protection and safety in the X-ray medical diagnostic in 1997 which was imparted at ININ. (Author)

  19. The IHS diagnostic X-ray equipment radiation protection program

    International Nuclear Information System (INIS)

    Knapp, A.; Byrns, G.; Suleiman, O.

    1994-01-01

    The Indian Health Service (IHS) operates or contracts with Tribal groups to operate 50 hospitals and approximately 165 primary ambulatory care centers. These facilities contain approximately 275 medical and 800 dental diagnostic x-ray machines. IHS environmental health personnel in collaboration with the Food and Drug Administration's (FDA) Center for Devices and Radiological Health (CDRH) developed a diagnostic x-ray protection program including standard survey procedures and menu-driven calculations software. Important features of the program include the evaluation of equipment performance collection of average patient entrance skin exposure (ESE) measurements for selected procedures, and quality assurance. The ESE data, collected using the National Evaluation of X-ray Trends (NEXT) protocol, will be presented. The IHS Diagnostic X-ray Radiation Protection Program is dynamic and is adapting to changes in technology and workload

  20. COMPARATIVE ANALYSIS OF MEDICAL EQUIPMENT USED IN DIAGNOSTIC IMAGING IN BULGARIA AND COUNTRIES WORLDWIDE AND OPTIMIZATION AIMED AT IMPROVING THE HEALTH CARE SYSTEM MANAGEMENT

    Directory of Open Access Journals (Sweden)

    Svetoslav Garov

    2016-07-01

    Full Text Available Purpose: to reveal the current condition of medical equipment in Bulgaria related to those major groups of socially significant diseases and to make an attempt to define guidelines for its optimization in view of improving the functioning and management of the healthcare system in this field. Material and methods: The following research methods have been applied: 1. Document review method – research, processing and analysis of medical statistical information taken from data from WHO and annual reports of NRA. The study includes data from 2009 - 2015. 2. Graphical method – summarizing data in relevant tables and diagram presentations. Results: The article analyzes the condition of medical equipment in the field of oncologic and cardiologic medical aid in Bulgaria based on data taken from WHO (World Health Organization and annual reports of NRA (Nuclear Regulatory Agency. Six types of diagnostic imaging and radiation therapy devices have been studied: Magnetic Resonance Imaging units (MRI; Computed Tomography Scanners (CT, Positron Emission Tomography Scanners, Mammographs, Linear accelerators and Telecobalt units (Cobalt-60. The condition of medical equipment since 2009 has been analyzed, results have been reported and trends - studied. Conclusion: The oncologic and cardiologic medical equipment in Bulgaria has been gradually improving in the last seven years, but quantitative indicators regarding the devices studied are still far away from the figures recommended by WHO with one single exception, i.e. Computed Tomography Scanners.

  1. An Interview with Medical Diagnostics Scientist Bernhard Weigl

    Science.gov (United States)

    Sullivan, Megan

    2010-01-01

    Medical diagnostics help us evaluate a range of disorders, such as cancer and infectious diseases. In the United States and other developed countries, doctors have access to advanced equipment and laboratories that provide reliable diagnoses. As a result, when we are sick, we feel confident that we will get the treatment we need. Unfortunately,…

  2. Preliminary evaluation of operational parameters in fixed x-ray diagnostics equipment

    International Nuclear Information System (INIS)

    Bacelar, Alexandre; Oliveira, Sandro Soletti de; Streck, Elaine E.; Furtado, Alvaro Porto Alegre; Pinto, Ana Lucia Acosta

    1998-01-01

    In this work they were appraised 22 fixed X-ray diagnostic equipment belonging to three great medical institutions in Porto Alegre - RS, Brazil, with the purpose of demonstrating the importance of the implementation of a Quality Warranty program, advised by a health physicist, in the performance of these equipment. For so some data of alignment and collimation of the beam, peak tube voltage, tube current, transportable charge and exposition time were collected. The results of the tests showed that in only one of the institutions all the equipment remained in operationally acceptable conditions, with relative percent errors below 10%, concerning to the analyzed parameters. This study also showed that the performance of the equipment of the three analyzed institutions is a direct reflex of the maintenance of a Quality Warranty Program, advised by a qualified professional. (author)

  3. Development of an equipment diagnostic system that evaluates sensor drift

    International Nuclear Information System (INIS)

    Kanada, Masaki; Arita, Setsuo; Tada, Nobuo; Yokota, Katsuo

    2011-01-01

    The importance of condition monitoring technology for equipment has increased with the introduction of condition-based maintenance in nuclear power plants. We are developing a diagnostic system using process signals for plant equipment, such as pumps and motors. It is important to enable the diagnostic system to distinguish sensor drift and equipment failure. We have developed a sensor drift diagnostic method that combines some highly correlative sensor signals by using the MT (Mahalanobis-Taguchi) method. Furthermore, we have developed an equipment failure diagnostic method that measures the Mahalanobis distance from the normal state of equipment by the MT method. These methods can respectively detect sensor drift and equipment failure, but there are the following problems. In the sensor drift diagnosis, there is a possibility of misjudging the sensor drift when the equipment failure occurs and the process signal changes because the behavior of the process signal is the same as that of the sensor drift. Oppositely, in the equipment failure diagnosis, there is a possibility of misjudging the equipment failure when the sensor drift occurs because the sensor drift influences the change of process signal. To solve these problems, we propose a diagnostic method combining the sensor drift diagnosis and the equipment failure diagnosis by the MT method. Firstly, the sensor drift values are estimated by the sensor drift diagnosis, and the sensor drift is removed from the process signal. It is necessary to judge the validity of the estimated sensor drift values before removing the sensor drift from the process signal. We developed a method for judging the validity of the estimated sensor drift values by using the drift distribution based on the sensor calibration data. And then, the equipment failure is diagnosed by using the process signals after removal of the sensor drifts. To verify the developed diagnostic system, several sets of simulation data based on abnormal cases

  4. Lists I and II, nuclear medical diagnostics. As of January 18, 1983

    International Nuclear Information System (INIS)

    1983-01-01

    The information booklet presents the guidelines of the Federal Association of Panel Doctors, concerning the minimum equipment required for nuclear medical diagnostics practices (nuclear medical equipment guidelines), in the amended version of May 18, 1981; it also contains the list I (modern commercially available equipment) and the list II (older types of equipment). The devices specified in these lists are products of firms that are members of the ZVEI, and are in compliance with the guidelines of the Panel Doctors' Association. Combinations of older computer equipment/cameras with up-to-date equipment, also come up to the standards given in the guidelines if specifically mentioned therein. The list of manufacturers gives addresses of the manufacturers of the equipment stated in list I and II. An appendix up-dates the information to the date of October 1, 1986. (orig./HP) [de

  5. Fitness of equipment used for medical exposures to ionising radiation

    International Nuclear Information System (INIS)

    1998-01-01

    The advice in this guidance note is aimed at employers in control of equipment used for medical exposures to ionising radiation and ancillary equipment. This includes NHS trusts, health authorities or boards, private hospitals, clinics, surgeries, medical X-ray facilities in industry, dentists and chiropractors. The guidance should also be useful to radiation protection advisers appointed by such employers. The guidance provides advice on the requirements of regulation 33 of the Ionising Radiations Regulations 1985 (IRR85). In particular, it covers: (a) the selection, installation, maintenance, calibration and replacement of equipment to ensure that it is capable of restricting, so far as reasonably practicable, the medical exposure of any person to the extent that this is compatible with the intended diagnostic or therapeutic purpose; (b) recommended procedures for the definitive calibration of radiotherapy treatment; and (c) the need to investigate incidents involving a malfunction or defect in any 'radiation equipment' which result in medical exposures much greater than intended and to notify the Health and Safety Executive (HSE). 'Medical exposure' is defined in IRR85 as exposure of a person to ionising radiation for the purpose of his or her medical or dental examination or treatment which is conducted under the direction of a suitably qualified person and includes any such examination or treatment conducted for the purposes of research. For convenience, people undergoing medical exposure will be referred to as 'patients' in this guidance. Nothing in this publication is intended to indicate whether or not patients should be informed of any incident resulting from malfunction or defect in equipment used for medical exposure and the possible consequences of that exposure. As stated above, this guidance concerns medical exposures much greater than intended and although exposures much lower than intended can also have serious consequences, the incident would not

  6. Diagnostic x-ray equipment and its use

    International Nuclear Information System (INIS)

    1993-01-01

    The guide contains the requirements for the use, structure and operation of diagnostic x-ray equipment necessary to ensure the radiation safety of workers and patients. The guide is intended for the party responsible for operating the x-ray units, the staff operating, installing and maintaining x-ray examination equipment, and companies manufacturing and selling such equipment. Special requirements for mammographic and dental x-ray equipments are given in separate ST guides. (5 refs., 1 figs., 2 tabs.)

  7. Medical image compression and its application to TDIS-FILE equipment

    International Nuclear Information System (INIS)

    Tsubura, Shin-ichi; Nishihara, Eitaro; Iwai, Shunsuke

    1990-01-01

    In order to compress medical images for filing and communication, we have developed a compression algorithm which compresses images with remarkable quality using a high-pass filtering method. Hardware for this compression algorithm was also developed and applied to TDIS (total digital imaging system)-FILE equipment. In the future, hardware based on this algorithm will be developed for various types of diagnostic equipment and PACS. This technique has the following characteristics: (1) significant reduction of artifacts; (2) acceptable quality for clinical evaluation at 15:1 to 20:1 compression ratio; and (3) high-speed processing and compact hardware. (author)

  8. Equipment for isotope diagnostics

    International Nuclear Information System (INIS)

    Platz, W.

    1976-01-01

    The invention concerns an improvement of equipment for isotope diagnostics allowing to mark special intensity ranges of the recorded measurements by means of different colors. For undisturbed operation it is of advantage to avoid electric circuits between movable and unmovable parts of the color recorder. According to the invention, long gear wheels of glass fiber-reinforced polyamide are used for these connections. (ORU) [de

  9. Comparative survey of site and personnel monitoring characteristics for operation of various types of diagnostic-X ray equipment

    International Nuclear Information System (INIS)

    Lyarskij, P.P.; Zol'nikova, N.I.

    1977-01-01

    Diagnostic X-ray machines in present use at medical facilities differ in design and operating parameters, this diversity producing, in turn, a variety of local radiological situations and levels of personnel exposure. Based on radiological safety characterization of working conditions, the authors present a breakdown of contemporary diagnostic X-ray equipment types, based on detailed examination of each group in terms of their associated site monitoring and dosimetry patterns. The paper reports data on personnel exposure levels not only as a function of equipment design and operating characteristics but also according to types of occupational activities for particular medical personnel groups (radiologists, surgeons, anesthesiologists, etc.). Included are health physics data for domestic and foreign X-ray equipment, levels of local and absorbed doses for radiologists, cardiovascular surgeons, neurosurgeons, urologists, traumatologists, anesthesiologists, etc. Measures are recommended for optimizing their activities from the standpoint of radiation safety. (author)

  10. A study on enforcement effects of radiation safety control regulations for diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Sung, Mo IL; Park, Myeong Hwan; Kwon, Duk Moon; Lee, Joon IL

    1999-01-01

    The purposes of this study are to analyze the realities after enforcements of safety control regulations for diagnostic X-ray equipment and to suggest means for an improvement of low radiation safety control. A questionnaire survey for medical radiologic technologists was carried out to determine enforcement effects of the safety control regulations. The results of analysis from the survey are as follows. That is, most of he respondents realized the importance of the radiation safety control system, but about a half of them revealed that regulations were not well observed in accordance with their purposes. Only 43.9 percent of the respondents took an active part in quality control of radiation. And responsibility, sex, age, and knowledge for safety control were important indicators for observations of the regulations. Training for the safety control regulations are needed to ensure safety control and proper usage of diagnostic X-ray equipment. And management of organizations using diagnostic X-ray equipment have to understand and stress the importance of radiation safety control system. (author)

  11. Low activation diagnostic equipment design studies

    International Nuclear Information System (INIS)

    Hopkins, G.R.; Cheng, E.T.; Fisher, R.K.

    1985-01-01

    The low activation fusion concept has been applied to the diagnostic equipment in a fusion reactor. The components where fabrication from low activation materials is feasible have been identified. Other systems where higher activation elements are required can have their activation reduced by design approaches which include shielding and operation only in low flux regions of the reactor. Some components will not operate in a high flux so activation is not a major concern. This low activation diagnostic equipment study completes a series of low activation studies where all the components in a fusion power reactor have now been evaluated. It is concluded that a completely low activation fusion reactor is feasible with all components meeting the functional requirements. This provides an environmentally benign energy source with a high confidence level in meeting safety criteria in operation, maintenance and waste disposal

  12. Prioritic directions of inculcation of diagnostic equipment at NPP

    International Nuclear Information System (INIS)

    Morozov, V.I.

    2000-01-01

    The diagnostic provision creates the conditions for increasing the safety and reliability of the NPP functioning, technical service and maintenance by the actual state. With an account of the large number of the NPP equipment elements, limitedness of financial resources, different technical-economical effect from diagnostics determination of the priority directions for introduction of technical diagnostic means into the operational practice is one of the main factors. The method for determining the above-mentioned priorities is proposed. The main aspects of the method and mathematical models, based on the logical-probabilistic modeling, are presented. The essence of the method consists in ranging the technical-economical effect from introduction of various factors of the diagnostic equipment [ru

  13. [Application of information management system about medical equipment].

    Science.gov (United States)

    Hang, Jianjin; Zhang, Chaoqun; Wu, Xiang-Yang

    2011-05-01

    Based on the practice of workflow, information management system about medical equipment was developed and its functions such as gathering, browsing, inquiring and counting were introduced. With dynamic and complete case management of medical equipment, the system improved the management of medical equipment.

  14. Medical equipment in government health facilities: Missed opportunities

    OpenAIRE

    Pardeshi Geeta

    2005-01-01

    BACKGROUND: The availability and optimal utilization of medical equipment is important for improving the quality of health services. Significant investments are made for the purchase, maintenance and repair of medical equipment. Inadequate management of these equipment will result in financial losses and deprive the public of the intended benefits. This analysis is based on the conceptual framework drawn from the WHO recommended- lifecycle of medical equipment. AIMS: (1) To identify the probl...

  15. Diagnostic X-ray equipment evaluation in Brazil

    International Nuclear Information System (INIS)

    Campos de Araujo, A.M.; Peixoto, J.E.; Reis, V.R.G.

    1980-01-01

    A survey of the diagnostic X-ray equipment in use in Brazil is presented. Procedures for testing radiation quality (kilovoltage and filtration), tube output, beam collimation and protection devices are described and results of tests are tabulated. (H.K.)

  16. Technical diagnostics - equipment monitoring for increasing safety and availability of nuclear power plants

    International Nuclear Information System (INIS)

    Sturm, A.; Foerster, R.

    1977-01-01

    Utilization of technical diagnostics in equipment monitoring of nuclear power plants for ensuring nuclear safety, economic availability, and for decision making on necessary maintenance is reviewed. Technical diagnostics is subdivided into inspection and early detection of malfunctions. Moreover, combination of technical diagnostics and equipment monitoring, integration of technical diagnostics into maintenance strategy, and problems of introducing early detection of malfunctions into maintenance management of nuclear power plants are also discussed. In addition, a compilation of measuring techniques used in technical diagnostics has been made. The international state of the art of equipment monitoring in PWR nuclear power plants is illustrated by description of the sound and vibration measuring techniques. (author)

  17. Radiation protection calculations for diagnostic medical equipment

    International Nuclear Information System (INIS)

    Klueter, R.

    1992-01-01

    The standards DIN 6812 and DIN 6844 define the radiation protection requirements to be met by biomedical radiography equipment or systems for nuclear medicine. The paper explains the use of a specific computer program for radiation protection calculations. The program offers menu-controlled calculation, with free choice of the relevant nuclides. (DG) [de

  18. Development of process diagnostic techniques for piping and equipment

    International Nuclear Information System (INIS)

    Yotsutsuji, Mitoshi

    1987-01-01

    The thing required for using the facilities composing a plant for a long period without anxiety is to quantitatively grasp the quantities of the present condition of the facilities and to take the necessary measures beforehand. For this purpose, the diagnostic techniques for quickly and accurately detect the quantities of the condition of facilities are necessary, and the development of process diagnostic techniques has been desired. The process diagnostic techniques mentioned here mean those for diagnosing the contamination, clogging and performance of towers, tanks, heat exchangers and others. Idemitsu Engineering Co. had developed a simplified diagnostic equipment for detecting the state of fouling in piping in 1982, which is the gamma ray transmission diagnosis named Scale Checker. By further improving it, the process diagnostic techniques for piping and equipment were developed. In this report, the course of development and examination, the principle of detection, the constitution and the examination of remodeling of the Scale Checker are reported. As the cases of process diagnosis in plant facilities, the diagnosis of the clogging in process piping and the diagnosis of the performance of a distillation tower were carried out. The contents of the diagnosis and the results of those cases are explained. (Kako, I.)

  19. Medical equipment in government health facilities: missed opportunities.

    Science.gov (United States)

    Pardeshi, Geeta S

    2005-01-01

    The availability and optimal utilization of medical equipment is important for improving the quality of health services. Significant investments are made for the purchase, maintenance and repair of medical equipment. Inadequate management of these equipment will result in financial losses and deprive the public of the intended benefits. This analysis is based on the conceptual framework drawn from the WHO recommended- lifecycle of medical equipment. (1) To identify the problems in different stages of the life cycle. (2) To assess its financial implications and effect on service delivery. Analysis of secondary data from the latest Comptroller and Auditor General (CAG) Reports for the states in India. The study variables were category of equipment, financial implications and problems in the stages of life cycle. Calculation of proportions. A total of forty instances mentioning problems in the first phase of the life cycle of medical equipment were noted in 12 state reports. The equipment from the radiology department (15), equipment in the wards (5), laboratory (3) and operation theatres (4) were the ones most frequently implicated. In a majority of cases the financial implications amounted to twenty-five lakhs. The financial implications were in the form of extra expenditure, unfruitful expenditure or locking of funds. In 25 cases the equipment could not be put to use because of non-availability of trained staff and inadequate infrastructural support. Careful procurement, incoming inspection, successful installation and synchronization of qualified trained staff and infrastructural support will ensure timely onset of use of the equipment.

  20. Methods for improvement of some parameters of medical X-ray diagnostic equipment. Basic faults in selection of appropriate new or used units

    International Nuclear Information System (INIS)

    Tonev, M.; Danev, N.; Constantinov, B.

    2004-01-01

    An analysis is made of the factors determining the quality and performance of the main types of medical equipment: conventional radiographic and fluoroscopic X-ray unit; X-ray computer tomograph (CT); angiographic, mammographic, densitometric and dental X-ray equipment; magnetic resonance MRI. The aim is to give certain directions for the method one should adopt on choosing and purchasing X-ray equipment. Also one should take into consideration the new Health law and the Regulation for radiation protection of persons undergoing medical examination or treatment. The problems can be solved with the close cooperation between radiologists, medical physicists and x-ray engineers

  1. Lack of security of networked medical equipment in radiology.

    Science.gov (United States)

    Moses, Vinu; Korah, Ipeson

    2015-02-01

    OBJECTIVE. There are few articles in the literature describing the security and safety aspects of networked medical equipment in radiology departments. Most radiologists are unaware of the security issues. We review the security of the networked medical equipment of a typical radiology department. MATERIALS AND METHODS. All networked medical equipment in a radiology department was scanned for vulnerabilities with a port scanner and a network vulnerability scanner, and the vulnerabilities were classified using the Common Vulnerability Scoring System. A network sniffer was used to capture and analyze traffic on the radiology network for exposure of confidential patient data. We reviewed the use of antivirus software and firewalls on the networked medical equipment. USB ports and CD and DVD drives in the networked medical equipment were tested to see whether they allowed unauthorized access. Implementation of the virtual private network (VPN) that vendors use to access the radiology network was reviewed. RESULTS. Most of the networked medical equipment in our radiology department used vulnerable software with open ports and services. Of the 144 items scanned, 64 (44%) had at least one critical vulnerability, and 119 (83%) had at least one high-risk vulnerability. Most equipment did not encrypt traffic and allowed capture of confidential patient data. Of the 144 items scanned, two (1%) used antivirus software and three (2%) had a firewall enabled. The USB ports were not secure on 49 of the 58 (84%) items with USB ports, and the CD or DVD drive was not secure on 17 of the 31 (55%) items with a CD or DVD drive. One of three vendors had an insecure implementation of VPN access. CONCLUSION. Radiologists and the medical industry need to urgently review and rectify the security issues in existing networked medical equipment. We hope that the results of our study and this article also raise awareness among radiologists about the security issues of networked medical equipment.

  2. RESULTS OF THE SURVEY CONDUCTED AMONG OPHTHALMOLOGISTS ON THE ISSUE OF EQUIPMENT OF MEDICAL INSTITUTIONS WITH OPHTHALMOLOGY DEVICES

    Directory of Open Access Journals (Sweden)

    S. V. Seraphimov

    2017-01-01

    Full Text Available Introduction. The problem of limited accessibility and quality of ophthalmic medical care remains one of the leading ones in the national healthcare. This article presents results of the survey conducted among ophthalmologists about the effect of large-scale equipment of all medical institutions in the Leningrad Region with modern ophthalmologic devices over the recent years.Objective is to determine the contribution of the health care modernization program to equipping the medical institutions of the Leningrad Region with modern ophthalmologic medical devices, and to identify the main areas for improving the ophthalmologic care for residents of the Leningrad region with cataracts.Materials and methods. According to a specially developed questionnaire, 105 ophthalmologists from the Leningrad Region were interviewed. The survey was conducted among physicians working both in out-patient medical facilities and in medical facilities with in-patient modalities.Results. The results of the study confirmed positive changes that occurred in recent years as a result of equipping medical institutions with modern medical devices. Almost two-thirds (59.9% of respondents noted that equipping with modern medical devices had a significant impact on the quality of the medical and diagnostic measures carried out in healthcare facilities of the region.Conclusions. The equipment had a significant impact on the diagnosis and treatment of all kinds of diseases of the eye and its appendages, especially such eye disease which is so common among the population of the Leningrad Region as cataracts (75.0 per 100 ophthalmologists surveyed. At the same time, in spite of these efforts, the standard for equipping ophthalmologic departments in individual medical institutions has not been fully provided. Only every fifth (20.9% ophthalmologist noted during the survey that the list of available ophthalmic devices was sufficient, and that they all worked properly.

  3. Effectiveness of medical equipment donations to improve health systems: how much medical equipment is broken in the developing world?

    Science.gov (United States)

    Perry, Lora; Malkin, Robert

    2011-07-01

    It is often said that most of the medical equipment in the developing world is broken with estimates ranging up to 96% out of service. But there is little documented evidence to support these statements. We wanted to quantify the amount of medical equipment that was out of service in resource poor health settings and identify possible causes. Inventory reports were analyzed from 1986 to 2010, from hospitals in sixteen countries across four continents. The UN Human Development Index was used to determine which countries should be considered developing nations. Non-medical hospital equipment was excluded. This study examined 112,040 pieces of equipment. An average of 38.3% (42,925, range across countries: 0.83-47%) in developing countries was out of service. The three main causes were lack of training, health technology management, and infrastructure. We hope that the findings will help biomedical engineers with their efforts toward effective designs for the developing world and NGO's with efforts to design effective healthcare interventions.

  4. Quality control of conventional diagnostic radiology equipment in Serbia and Montenegro

    International Nuclear Information System (INIS)

    Ciraj, O.; Kosutic, D.; Markovic, S.

    2003-01-01

    There are more than 1500 diagnostic X-ray tubes in service in Serbia and Montenegro. Diagnostic X-ray equipment is checked on annual basis. X-ray equipment Qc protocols have been adopted from several international standards and guidelines [1,2], which have been modified according our practice and measuring equipment. According our inventory, about one half of all installed units is used for conventional X-ray diagnostics, 10% are mobile units, 2% of all in units in operation are mammographic devices an another 2% are computed tomography units. In addition there are about 600 dental X-ray units, which is 36% of all units. It is worth mentioning that almost 30 % of all installed units have single-phase generators, another 25% are tree phase (six and twelve pulse) generators and nearly 9% are high frequency units. Majority of units was installed more than 25 years ago. The Quality Control (QC) in radiography is a central part of QA programme, which deals with equipment maintenance and monitoring. QA in diagnostic radiology is a mean of maintaining standards in imaging and working towards minimizing patient and staff doses. As a part of QA programme in diagnostic radiology, the performance characteristics of 96 conventional X-ray units were measured in six months period during 2003. The diagnostic units were located in hospitals all over the country. They represent 25% of the total conventional diagnostic units of the country. About one half of measured X-ray units were new-installed. QC program has positive effect on X-ray equipment performance in a period of a few years. It is essential to perform QC tests for all installed X-ray units at least on annual basis. This would lead to production of consistent X-ray images, with minimal retake rate and hence, will contribute to decreasing of the patient dose. Patient doses are determined by multitude factors which interact in very complicated manner. It is very important to perform real patient dose measurements in

  5. Enhancing reactor availability factor by diagnostic monitoring and data acquisition of electrical equipments

    International Nuclear Information System (INIS)

    Singh, G.

    2006-01-01

    Electrical energy has made significant contribution to rapid growth of industrial activity in the country. Development and improvement of energy conversion devices or electrical apparatus have supported the growth. Reliability is probably the most important factor in electrical supply system, not only to give uninterrupted service but to provide an economic supply. Regular diagnostic testing of electrical equipments will make a significant contribution to the reliability of electrical supply. The purpose of diagnostic monitoring is to recognize the development of faults at an early stage, which consequently allows greater freedom to schedule the outages resulting in lower downtime and lower capitalized losses. The insulation constitutes the heart of any electrical/power equipment. The insulation in power equipment in normal condition undergoes certain changes in the physical, chemical, electrical and mechanical properties. The change with respect to time in the presence of an influencing factor, more often a stress (electrical) is referred to as ageing. The deterioration of insulating material plays an important role in the assessing the condition of electrical equipments. The systematic diagnostic tests are also part of the maintenance program to ensure the continued serviceability of electrical equipments, by replacing or repairing the components likely to fail, as revealed by the test. Diagnostic tests are carried out on various electrical equipments for detection of incipient fault, location and judging their severity. (author)

  6. Application of diagnostic reference levels in medical practice

    Energy Technology Data Exchange (ETDEWEB)

    Bourguignon, Michel [Faculty of Medicine of Paris, Deputy Director General, Nuclear Safety Authority (ASN), Paris (France)

    2006-07-01

    Diagnosis reference levels (D.R.L.) are defined in the Council Directive 97/43 EURATOM as 'Dose levels in medical radio diagnosis practices or in the case of radiopharmaceuticals, levels of activity, for typical examinations for groups of standards-sized patients or standards phantoms for broadly defined types of equipment. These levels are expected not to be exceeded for standard procedures when good and normal practice regarding diagnostic and technical performance is applied'. Thus D.R.L. apply only to diagnostic procedures and does not apply to radiotherapy. Radiation protection of patients is based on the application of 2 major radiation protection principles, justification and optimization. The justification principle must be respected first because the best way to protect the patient is not to carry a useless test. Radiation protection of the patient is a continuous process and local dose indicator values in the good range should not prevent the radiologist or nuclear medicine physician to continue to optimize their practice. (N.C.)

  7. Application of diagnostic reference levels in medical practice

    International Nuclear Information System (INIS)

    Bourguignon, Michel

    2006-01-01

    Diagnosis reference levels (D.R.L.) are defined in the Council Directive 97/43 EURATOM as 'Dose levels in medical radio diagnosis practices or in the case of radiopharmaceuticals, levels of activity, for typical examinations for groups of standards-sized patients or standards phantoms for broadly defined types of equipment. These levels are expected not to be exceeded for standard procedures when good and normal practice regarding diagnostic and technical performance is applied'. Thus D.R.L. apply only to diagnostic procedures and does not apply to radiotherapy. Radiation protection of patients is based on the application of 2 major radiation protection principles, justification and optimization. The justification principle must be respected first because the best way to protect the patient is not to carry a useless test. Radiation protection of the patient is a continuous process and local dose indicator values in the good range should not prevent the radiologist or nuclear medicine physician to continue to optimize their practice. (N.C.)

  8. Management information system of medical equipment using mobile devices

    Science.gov (United States)

    Núñez, C.; Castro, D.

    2011-09-01

    The large numbers of technologies currently incorporated into mobile devices transform them into excellent tools for capture and to manage the information, because of the increasing computing power and storage that allow to add many miscellaneous applications. In order to obtain benefits of these technologies, in the biomedical engineering field, it was developed a mobile information system for medical equipment management. The central platform for the system it's a mobile phone, which by a connection with a web server, it's capable to send and receive information relative to any medical equipment. Decoding a type of barcodes, known as QR-Codes, the management process is simplified and improved. These barcodes identified the medical equipments in a database, when these codes are photographed and decoded with the mobile device, you can access to relevant information about the medical equipment in question. This Project in it's actual state is a basic support tool for the maintenance of medical equipment. It is also a modern alternative, competitive and economic in the actual market.

  9. [Fundamental aspects for accrediting medical equipment calibration laboratories in Colombia].

    Science.gov (United States)

    Llamosa-Rincón, Luis E; López-Isaza, Giovanni A; Villarreal-Castro, Milton F

    2010-02-01

    Analysing the fundamental methodological aspects which should be considered when drawing up calibration procedure for electro-medical equipment, thereby permitting international standard-based accreditation of electro-medical metrology laboratories in Colombia. NTC-ISO-IEC 17025:2005 and GTC-51-based procedures for calibrating electro-medical equipment were implemented and then used as patterns. The mathematical model for determining the estimated uncertainty value when calibrating electro-medical equipment for accreditation by the Electrical Variable Metrology Laboratory's Electro-medical Equipment Calibration Area accredited in compliance with Superintendence of Industry and Commerce Resolution 25771 May 26th 2009 consists of two equations depending on the case; they are: E = (Ai + sigmaAi) - (Ar + sigmaAr + deltaAr1) and E = (Ai + sigmaAi) - (Ar + sigmaA + deltaAr1). The mathematical modelling implemented for measuring uncertainty in the Universidad Tecnológica de Pereira's Electrical Variable Metrology Laboratory (Electro-medical Equipment Calibration Area) will become a good guide for calibration initiated in other laboratories in Colombia and Latin-America.

  10. Course of radiological protection and safety in the medical diagnostic with X-rays; Curso de proteccion y seguridad radiologica en el diagnostico medico con rayos X

    Energy Technology Data Exchange (ETDEWEB)

    Dominguez A, C.E. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1997-07-01

    The obtention of images of human body to the medical diagnostic is one of the more old and generalized applications for X-ray. Therefore the design and performance of equipment and installations as well as the operation procedures must be oriented toward safety with the purpose to guarantee this radiological practice will bring a net positive benefit to the society. Given that in Mexico only exists the standardization related to source and equipment generators of ionizing radiation in the industrial area and medical therapy, but not so to the medical diagnostic area it is the purpose of this work to present those standards related with this application branch. Also it is presented the preparation of a manual for the course named Formation of teachers in radiological protection and safety in the X-ray medical diagnostic in 1997 which was imparted at ININ. (Author)

  11. Diagnostics of heavy mining equipment during the scheduled preventive maintenance

    Science.gov (United States)

    Drygin, M. Yu; Kuryshkin, N. P.

    2018-01-01

    Intensification of production, economic globalization and dramatic downgrade of the workers’ professional skills lead to unacceptable technical state of heavy mining equipment. Equipment maintenance outage reaches 84 % of the total downtime, of which emergency maintenance takes up to 36 % of time, that excesses 429 hours per year fr one excavator. It is shown that yearly diagnostics using methods of non-destructive check allows to reduce emergency downtime by 47 %, and 55 % of revealed defects can be eliminated without breaking the technological cycle of the equipment.

  12. Quantitative techniques for medical equipment maintenance management

    NARCIS (Netherlands)

    Ben Houria, Zeineb; Masmoudi, Malek; Al Hanbali, Ahmad; Khatrouch, Ikram; Masmoudi, Faouzi

    2016-01-01

    The maintenance department in a hospital is responsible for ensuring the safety of medical equipment and their availability while keeping the operation costs minimal. The selection of the best maintenance strategy is a key decision to reduce the equipment downtime, increase the availability, and

  13. An H-module linear actuator for medical equipment applications

    DEFF Research Database (Denmark)

    Liu, Xiao; Wu, Keyuan; ye, yunyue

    2012-01-01

    An H-module linear actuator (HMLA) is proposed in this paper for medical equipment applications. Compared to the existing linear actuators used in medical equipment, the proposed H-module linear actuator has much lower normal force, which makes use of an additional air-suspension system unnecessary...

  14. FY 2000 Research and development of technology for medical and welfare equipment. Report on the comprehensive survey on welfare equipment; 2000 nendo iryo fukushi kiki gijutsu kenkyu kaihatsu chosa hokokusho. Fukushi kiki sogo chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    The survey is conducted on the advanced basic and application technologies for medical and welfare equipment, e.g., biotechnology and drug delivery systems, to promote development of these technologies. For development of the gene-aided diagnostic system equipment for clinical purposes, surveys are conducted on current medical equipment and related technologies, and the results are summarized and pigeonholed for each equipment type. Also summarized are the small- to medium-sized enterprises which are considered to have techniques needed for development of sensors for heart disease treatment systems. For usability of welfare-related equipment products, investigations are made viewed from the designs oriented to human adaptability, human adaptable designs in the aging societies, and welfare-related problems in the aging societies and usability. The latest information on leading organizations and researchers is collected, for continuation and development of the usability programs for welfare-related equipment products, and also for inviting the current related technologies and researchers on life supporting for the aged in Japan to the programs. (NEDO)

  15. The research of medical equipment on-line detection system based on Android smartphone

    Science.gov (United States)

    Jiang, Junjie; Dong, Xinyu; Zhang, Hongjie; Liu, Mengjun

    2017-06-01

    With the unceasing enhancement of medical level, the expanding scale of medical institutions, medical equipment as an important tool for disease diagnosis, treatment and prevention, used in all levels of medical institutions. The quality and accuracy of the Medical equipment play a key role in the doctor's diagnosis and treatment effect, medical metrology as the important technical foundation is to ensure that the equipment, technology, material components are accurate and the application is safe and reliable. Medical equipment have the feature of variety, large quantity, long using cycle, expensive and multi-site, which bring great difficulty in maintenance, equipment management and verification. Therefore, how to get the medical measurement integrate deeply into the advanced internet technology, information technology and the new measuring method, for real-time monitoring of medical equipment, tracking, positioning, and query is particularly important.

  16. Analysis of Medical Equipment Management in Relation to the Mandatory Medical Equipment Safety Manager (MESM in Japan

    Directory of Open Access Journals (Sweden)

    Kai Ishida

    2014-01-01

    Full Text Available Half a decade has passed since the fifth revision of the medical law and mandatory appointment of a medical equipment safety manager (MESM in hospitals in Japan. During this period, circumstances have changed regarding maintenance of medical equipment (ME. We conducted a survey to examine these changes and the current situation in ME management. Maintenance of ME and related work were found to have increased in many hospitals, but the number of clinical engineering technologists (CETs has only slightly increased. The appointed MESM was a CET or physician in most hospitals. In hospitals where physicians were appointed as the MESM, 81% had operation managers. Many respondents commented that it was difficult for one person to cover all the tasks required by the MESM, due to a lack of knowledge, too much work, or other reasons. This suggests the importance of an operation manager for ME to work under the MESM.

  17. Ethical home medical equipment business practices.

    Science.gov (United States)

    Parver, C

    1991-11-01

    National uniform standards as a condition for receipt of a Medicare provider number would help rid the home medical equipment industry of those unethical and unscrupulous suppliers who have tarnished the industry's reputation.

  18. The influence of experiential learning on medical equipment adoption in general practices.

    Science.gov (United States)

    Bourke, Jane; Roper, Stephen

    2014-10-01

    The benefits of the availability and use of medical equipment for medical outcomes are understood by physicians and policymakers alike. However, there is limited understanding of the decision-making processes involved in adopting and using new technologies in health care organisations. Our study focuses on the adoption of medical equipment in Irish general practices which are marked by considerable autonomy in terms of commercial practice and the range of medical services they provide. We examine the adoption of six items of medical equipment taking into account commercial, informational and experiential stimuli. Our analysis is based on primary survey data collected from a sample of 601 general practices in Ireland on practice characteristics and medical equipment use. We use a multivariate Probit to identify commonalities in the determinants of the adoption. Many factors, such as GP and practice characteristics, influence medical equipment adoption. In addition, we find significant and consistent evidence of the influence of learning-by-using effects on the adoption of medical equipment in a general practice setting. Knowledge generated by experiential or applied learning can have commercial, organisational and health care provision benefits in small health care organisations. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  19. Medical Equipment Management through the Use of Radio Frequency Identification (RFID)

    National Research Council Canada - National Science Library

    Sanchez, Joaquin

    2004-01-01

    ...) in the management of medical equipment at Naval Medical Center San Diego (NMCSD). In doing so, the project seeks to derive potential benefits through the use of RFID technology by comparing a group of medical equipment items that are tracked within NMCSD...

  20. Preventive maintenance prioritization index of medical equipment using quality function deployment.

    Science.gov (United States)

    Saleh, Neven; Sharawi, Amr A; Elwahed, Manal Abd; Petti, Alberto; Puppato, Daniele; Balestra, Gabriella

    2015-05-01

    Preventive maintenance is a core function of clinical engineering, and it is essential to guarantee the correct functioning of the equipment. The management and control of maintenance activities are equally important to perform maintenance. As the variety of medical equipment increases, accordingly the size of maintenance activities increases, the need for better management and control become essential. This paper aims to develop a new model for preventive maintenance priority of medical equipment using quality function deployment as a new concept in maintenance of medical equipment. We developed a three-domain framework model consisting of requirement, function, and concept. The requirement domain is the house of quality matrix. The second domain is the design matrix. Finally, the concept domain generates a prioritization index for preventive maintenance considering the weights of critical criteria. According to the final scores of those criteria, the prioritization action of medical equipment is carried out. Our model proposes five levels of priority for preventive maintenance. The model was tested on 200 pieces of medical equipment belonging to 17 different departments of two hospitals in Piedmont province, Italy. The dataset includes 70 different types of equipment. The results show a high correlation between risk-based criteria and the prioritization list.

  1. Comprehensive framework for preventive maintenance priority of medical equipment.

    Science.gov (United States)

    Saleh, Neven; Balestra, Gabriella

    2015-08-01

    Throughout the medical equipment life cycle, preventive maintenance is considered one of the most important stages that should be managed properly. However, the need for better management and control by giving a reasonable prioritization for preventive maintenance becomes essential. The purpose of this study is to develop a comprehensive framework for preventive maintenance priority of medical equipment using Quality Function Deployment (QFD) and Fuzzy Logic (FL). The quality function deployment is proposed in order to identify the most important criteria that could impact preventive maintenance priority decision; meanwhile the role of the fuzzy logic is to generate a priority index of the list of equipment considering those criteria. The model validation was carried out on 140 pieces of medical equipment belonging to two hospitals. In application, we propose to classify the priority index into five classes. The results indicate that the strong correlation existence between risk-based criteria and preventive maintenance priority decision.

  2. Intelligent systems in technical and medical diagnostics

    CERN Document Server

    Korbicz, Jozef

    2013-01-01

    For many years technical and medical diagnostics has been the area of intensive scientific research. It covers well-established topics as well as emerging developments in control engineering, artificial intelligence, applied mathematics, pattern recognition and statistics. At the same time, a growing number of applications of different fault diagnosis methods, especially in electrical, mechanical, chemical and medical engineering, is being observed. This monograph contains a collection of 44 carefully selected papers contributed by experts in technical and medical diagnostics, and constitutes

  3. How 3D immersive visualization is changing medical diagnostics

    Science.gov (United States)

    Koning, Anton H. J.

    2011-03-01

    Originally the only way to look inside the human body without opening it up was by means of two dimensional (2D) images obtained using X-ray equipment. The fact that human anatomy is inherently three dimensional leads to ambiguities in interpretation and problems of occlusion. Three dimensional (3D) imaging modalities such as CT, MRI and 3D ultrasound remove these drawbacks and are now part of routine medical care. While most hospitals 'have gone digital', meaning that the images are no longer printed on film, they are still being viewed on 2D screens. However, this way valuable depth information is lost, and some interactions become unnecessarily complex or even unfeasible. Using a virtual reality (VR) system to present volumetric data means that depth information is presented to the viewer and 3D interaction is made possible. At the Erasmus MC we have developed V-Scope, an immersive volume visualization system for visualizing a variety of (bio-)medical volumetric datasets, ranging from 3D ultrasound, via CT and MRI, to confocal microscopy, OPT and 3D electron-microscopy data. In this talk we will address the advantages of such a system for both medical diagnostics as well as for (bio)medical research.

  4. Clarification of radiation-control regulations for diagnostic x-ray equipment

    International Nuclear Information System (INIS)

    1989-03-01

    The Office of Compliance and Surveillance of the Center for Devices and Radiological Health (CDRH) has received many requests for interpretation of the Federal regulations that relate to diagnostic x-ray equipment. Responses to these requests were originally issued as FDA Compliance Policy Guides, industry-wide letters, and letters to individuals. The document is a compilation of those responses that remain applicable. Guides or opinions that have been withdrawn or are now obsolete because they have been incorporated into the regulations are not included. The document consists of two sections: the General section, which contains information of a general nature; and the Specific section, which contains information specific to particular sections of the Federal Performance Standard for Diagnostic X-ray Equipment (21 CFR 1020.30-32). When the term 'Revised Language' appears in an item heading, it indicates English grammar correction; the term 'Revised' indicates an updated version of the original clarification

  5. BIOANALYTICAL STANDARDIZING FOR SEROLOGICAL DIAGNOSTIC MEDICAL DEVICES

    Directory of Open Access Journals (Sweden)

    A. Yu. Galkin

    2015-04-01

    Full Text Available In article we analyzed national and international regulations concerning the quality and safety of medical devices for in vitro diagnostics. We discussed the possibility of a partial application of the recommendations of the State Pharmacopoeia of Ukraine to this type of product. The main guiding regulatory documents establishing requirements for quality and safety tools for the serological diagnosis products are The technical regulation on medical devices for the diagnosis in vitro, DSTU ISO 13485 “Medical devices. Quality management system. Regulatory requirements”, and DSTU ISO/IEC 17025 “General requirements for the competence of testing and calibration laboratories”. Similar requirements of the State Pharmacopoeia of Ukraine which are used for drug standardization can not be directly applied to the medical devises for in vitro diagnostics due to a number of features, namely, the serological diagnosis products pre-designed to determine the unknown concentration of a particular analyte in a biological material, the diagnostic kits has to include the control samples (internal standard systems that need to be calibrated. It was determined following parameters of bioanalytical standardization and validation characterization for of qualitative (semi quantitative test-kits for serological diagnosis: precision (convergence, intralaboratory precision and reproducibility, diagnostic and analytical specificity, diagnostic sensitivity. It’s necessary to inspect additional parameters for quantitative test-kits such as accuracy (precision, linearity, analytical sensitivity and range.

  6. Role of the medical physicist in quality control in diagnostic x-ray departments

    International Nuclear Information System (INIS)

    Cameron, J.R.

    1973-01-01

    Medical physicists can play a role in education of future radiologists and technologists by teaching quality control needs and techniques. He or she can also provide service to the diagnostic section by establishing a quality control program. Finally, the medical physicist can play an important role in the development of simple and inexpensive techniques for quality control by radiological technologists. The ongoing work at the University of Wisconsin in this area is to provide quality control in measurement of the effective kVcp, the measurement of the effective focal spot size, the performance of the processing equipment, the output in mR/mAs, and the measurement of the half-value-layer and the total filtration. (U.S.)

  7. 78 FR 59623 - Emergency Medical Equipment

    Science.gov (United States)

    2013-09-27

    ... accordance with the FAA master minimum equipment list does not adversely affect aviation safety. This action... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration 14 CFR Parts 121 and 135 [Docket No... inoperative Emergency Medical Kit (EMK) or automated external defibrillator (AED). A copy of Master Minimum...

  8. Health technology assessment to improve the medical equipment life cycle management.

    Science.gov (United States)

    Margotti, Ana E; Ferreira, Filipa B; Santos, Francisco A; Garcia, Renato

    2013-01-01

    Health technology assessment (HTA) is a tool to support decision making that is intended to assist healthcare managers in their strategic decisions. The use of HTA as a tool for clinical engineering is especially relevant in the domain of the medical equipment once it could improve the performance of the medical equipment. It would be done by their systematically evaluation in several aspects, in their life cycle. In Brazil, the Institute of Biomedical Engineering (IEB-UFSC) through the clinical engineering area has been working on the development of methodologies and improvements on HTA for medical equipment. Therefore, this paper presents the effort to create specific methodologies that will improve the dissemination of HTA, focusing on incorporation and utilization phase of the medical equipment life cycle. This will give a better support to the decision makers in the management of the health care system.

  9. Diagnostic reference levels in medical imaging

    International Nuclear Information System (INIS)

    Rosenstein, M.

    2001-01-01

    The paper proposes additional advice to national or local authorities and the clinical community on the application of diagnostic reference levels as a practical tool to manage radiation doses to patients in diagnostic radiology and nuclear medicine. A survey was made of the various approaches that have been taken by authoritative bodies to establish diagnostic reference levels for medical imaging tasks. There are a variety of ways to implement the idea of diagnostic reference levels, depending on the medical imaging task of interest, the national or local state of practice and the national or local preferences for technical implementation. The existing International Commission on Radiological Protection (ICRP) guidance is reviewed, the survey information is summarized, a set of unifying principles is espoused and a statement of additional advice that has been proposed to ICRP Committee 3 is presented. The proposed advice would meet a need for a unifying set of principles to provide a framework for diagnostic reference levels but would allow flexibility in their selection and use. While some illustrative examples are given, the proposed advice does not specify the specific quantities to be used, the numerical values to be set for the quantities or the technical details of how national or local authorities should implement diagnostic reference levels. (author)

  10. Guidelines for Quality Control of Equipment Used in Diagnostic Radiology in the Netherlands

    International Nuclear Information System (INIS)

    Berg, L. van den; Aarts, C.N.M.; Beentjes, L.B.; Dalen, A. van; Elsakkers, P.; Julius, H.W.; Kicken, P.J.H.; Meer, F. van der; Teeuwisse, W.; Thijssen, M.A.O.; Zoetelief, J.

    1998-01-01

    The Dutch working group on 'Quality Criteria for Equipment Used in Diagnostic Radiology' has formulated guidelines providing technical criteria for equipment used in conventional diagnostic radiology. These guidelines are applicable to the technical parameters having a major impact on image quality and patient dose and include methods for testing. The following parameters are included: tube voltage, automatic exposure control, film processing, film-screen combination, light tightness and illumination of the dark room, half-value layer and filtration, light field, grid, focal spot size, viewing boxes and geometrical indicators. Each guideline consists of the following chapters: (1) Scope and field of application, (2) Background information, (3) Test procedure, (4) Test frequency, (5) Registration of observations, (6) Evaluation and interpretation, (7) Test report. Chapter 3 includes both the principles of the test method and a step by step description of the procedures. The principles of the test procedure provide a basis for adaptation to local circumstances. The step by step test procedure allows a quality control measurement to be performed with limited physical knowledge of the equipment. Chapter 6 includes limiting values. Draft guidelines were evaluated in practice in 20 hospitals. The final document has been accepted by the professional societies in the Netherlands and the Dutch Minister of Health as a reference set of tools to perform Quality Control of equipment used for conventional diagnostic radiology. (author)

  11. Imaging systems for medical diagnostics

    International Nuclear Information System (INIS)

    Krestel, E.

    1990-01-01

    This book provides physicians and clinical physicists with detailed information on today's imaging modalities and assists them in selecting the optimal system for each clinical application. Physicists, engineers and computer specialists engaged in research and development and sales departments will also find this book to be of considerable use. It may also be employed at universities, training centers and in technical seminars. The physiological and physical fundamentals are explained in part 1. The technical solutions contained in part 2 illustrate the numerous possibilities available in X-ray diagnostics, computed tomography, nuclear medical diagnostics, magnetic resonance imaging, sonography and biomagnetic diagnostics. (orig.)

  12. A study on the test of efficiency of the diagnostic X-ray equipment according to their rectifications

    International Nuclear Information System (INIS)

    Seon, Jong Ryul

    1997-01-01

    For the efficient management of the diagnostic x-ray equipment, a nation-wide inspection of hospitals was performed by an inspection institute in Taejon in the first half of 1997. Among those hospitals inspected, 28 equipments(machines) which were over 500 mA were randomly selected according to their characteristics : 7 condenser type x-ray equipments, 7 three control phase of full wave rectification of type remote control x-ray equipments, 7 single phase of full wave rectification type for general radiography equipments, and 7 single phase of full wave rectification type of R/F equipments. We obtained the following results by conducting the experiment based on the efficiency of the equipments mentioned above. 1) When te equipments are analyzed, 2 out of 7 single phase of full wave rectification type of general radiography equipments(28.6%), 3 out of 7 single phase of full wave rectification type of R/F equipments(42.9%), 5 out of 7 three phase of full wave rectification type remote of control x-ray equipments(71.4%), and 4 out of 7 condenser type of x-ray equipments(57.1%) showed suitability. It proves the superiority of the three phase of full wave rectification type of remote control x-ray equipments. 2) From the overall analysis, only about 50% of the equipments(suitability of 14 out of 28) maintain the efficient management. Therefore, maintenance management of equipments is more necessary. If the efficiency of the x-ray equipment is uniformly maintained and managed to prevent the breakdown(trouble) beforehand especially through the continuous inspection of tube voltage, tube current, exposure time, and collimator, the financial loss and exposure dose to the patient, as well as the workers engaged in radiation, can be reduced for better medical service

  13. Diagnostics of Electric Equipment Windings

    Directory of Open Access Journals (Sweden)

    I. I. Branovitsky

    2007-01-01

    Full Text Available The paper presents methodology and results of the investigations pertaining to study of influence of short-circuited turns on transient electrical processes in electric motor windings. Dependence of their damped speed and value of the difference signal, obtained at reciprocal subtraction of damped oscillation curves in absence and in presence of short-circuited turns, on number of turns in the tested windings. It has been determined that damped oscillation curves, immediately attributed to short-circuited turns, have peak values along temporary axis which are areas of the largest transient process sensitivity to КЗ turns.Methodology for diagnostics of single- and three-phase electric motor windings and also other electric equipment, being realized in DO-1 device, has been developed in the paper. The men­tioned device makes it possible to carry out visual comparison and quantitative analysis of damped oscillation curves in the tested windings with standard ones which are set in the device memory and their difference signals.

  14. Optimization of working conditions of medical staff of isotopic diagnostic departments. Optimizatsiya uslovij truda meditsinskogo personala radiodiagnosticheskikh otdelenij

    Energy Technology Data Exchange (ETDEWEB)

    Ovsyannikov, A S [Akademiya Meditsinskikh Nauk SSSR, Moscow (USSR). Inst. Gigieny Truda i Professional' nykh Zabolevanij

    1989-01-01

    The study was undertaken to analyze the characteristics of the work of medical staff of isotopic diagnostic departments during use of {sup 99m}Tc isotope generators. The data on the functional load of physicians and paramedical staff were given along with the description of radiation doses and dose rates at various stages of work. The measures on optimization of labour conditions by means of the appropriate department's design, improvement of the regime of nurses' work and adequate allocation and utilization of medical equipment were developed.

  15. Working with the medical equipment: the status of the medical physicist in Romania today

    International Nuclear Information System (INIS)

    Leanca, Valeria

    2008-01-01

    Full text: The presentation will emphasize on the following points: a) General Information; b) Medical Physics activities in the following fields; c) Role of the medical physicist; d) The National Government Organization and the implementation of the status of the medical physicist working in the hospitals in Romania; e) Organizational Structure; f) Purpose; g) Aims; h) Legislation of Medical Physics; i) Medical equipment in Romania (author)

  16. RESEARCH OF RUSSIAN HIGH TECHNOLOGY MEDICAL EQUIPMENT MARKET: THE SOCIO-ECONOMIC ASPECTS

    Directory of Open Access Journals (Sweden)

    Станислав Сергеевич Отставнов

    2013-04-01

    Full Text Available The article presents the data obtained from comprehensive study of russian hi-tech medical equipment market. The size and the structure of Russian medical equipment market in 2005-2011 were investigated and market size forecast for 2012-2015 was given. Priority segments of Russian high-tech medical equipment market were identified (products with a high degree of visualization, anesthetic and ventilation equipment, patient monitors  based on the analysis of literature sources and morbidity structure. Key players in key segments of the market were identified and their financial performance such as number of employees, revenue, net profit, researches and development expenses were compared (according to actual annual reports.Research allowed to draw the following conclusion: today in the key segments of Russian high-tech medical equipment market the leadership of foreign companies  (Hitachi, Philips, Siemens, Toshiba, General Electric, Dräger is indisputable, objective preconditions for the fundamental change of the situation are absent. Import substitution requires the consolidation of domestic producers, adequate funding and human resource.The results can be used in practice by medical industry companies and State authorities on purpose to upgrade the medical industry.DOI: http://dx.doi.org/10.12731/2218-7405-2013-1-31

  17. Use of Audiovisual Media and Equipment by Medical Educationists ...

    African Journals Online (AJOL)

    The most frequently used audiovisual medium and equipment is transparency on Overhead projector (O. H. P.) while the medium and equipment that is barely used for teaching is computer graphics on multi-media projector. This study also suggests ways of improving teaching-learning processes in medical education, ...

  18. Automated Quality Assurance of Medical Digital X-Ray Equipment

    International Nuclear Information System (INIS)

    Zelikman, Mikhail; Kruchinin, Sergey

    2013-06-01

    Quality assurance of the x-ray equipment includes a set of various tests among which are installation and periodic exams performed by qualified engineers as well as daily routine tests carried out by the medical staff of the Radiology Department. As a rule, the decision concerning the applicability of the x-ray equipment for using in clinical studies is made on the basis of the routine tests results. The presented method is based on the detector's output signals, Signal-to-Noise Ratio and Modulation Transfer Function evaluation in automated way using the simple test-object's digital image registered with given geometry and x-ray exposure parameters settings. Rectangular 20 mm thick aluminum plate with fixed 1 mm thick well-finished steel edge (for general x-ray radiography/fluoroscopy systems) or 2 mm thick aluminum plate with fixed 1 mm thick aluminum well-finished edge (for digital x-ray mammography systems) can be used as a test equipment. Relevant to the decision concerning the x-ray device operation status are the parameters: deviations from the reference levels of the tube voltage and mAs as well as internal detector's noise variance and detector's gain deviations. Everyday testing procedure includes the following steps. On the first step the roentgenographer places the test-object at the center of the detector's surface, makes an exposure with specified parameters setting and geometry and after this, test results are displayed on the work station monitor or console screen in automatic way. In order to provide an automated regime of the presenting algorithm, the software must be integrated with the program module intended for the x-ray device control. The use of the presented method in clinical practice provides the reliable daily monitoring of the x-ray equipment operation status prior to its utilizing for patient diagnostic process. As a rule, it will take not more than 3-5 minutes for the roentgenographer to complete the routine

  19. Performance testing of medical US equipment using US phantom (ATS-539)

    International Nuclear Information System (INIS)

    Kim, Do Hyung; Kwon, Deok Moon

    2014-01-01

    This study is to provide accurate information as medical imaging equipment to check for the presence of body disease US equipment. We investigated the status of medical US equipment performance in Daegu and criteria US phantom (ATS-539) for US equipment performance measurements. The results in this study, 1. US phantom measurement results: The test passed rate were 88.6% and the failed rate were 11.4%. 2. The difference between the group of mean and the pass/failed groups were statistically significant. Focal zone and 4 mm functional resolution in the two items that are not present the passing standard. 3. The difference was statistically significant number of years and used equipment and pass the failed equipment (4.13 vs 7.25 years). We investigated the performance status of US equipment used in the clinical area in Daegu. The basis for the two items are not present this proposed passing standard. Equipment performance was associated with the number of years of using US equipment. It is necessary to maintain the best performance of the equipment phantom measurements for performance testing of US equipment

  20. Performance testing of medical US equipment using US phantom (ATS-539)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Do Hyung [Daegu Branch, Korea Association of Health Promotion, Daegu (Korea, Republic of); Kwon, Deok Moon [Dept. of Radiology, Daegu Health College, Daegu (Korea, Republic of)

    2014-12-15

    This study is to provide accurate information as medical imaging equipment to check for the presence of body disease US equipment. We investigated the status of medical US equipment performance in Daegu and criteria US phantom (ATS-539) for US equipment performance measurements. The results in this study, 1. US phantom measurement results: The test passed rate were 88.6% and the failed rate were 11.4%. 2. The difference between the group of mean and the pass/failed groups were statistically significant. Focal zone and 4 mm functional resolution in the two items that are not present the passing standard. 3. The difference was statistically significant number of years and used equipment and pass the failed equipment (4.13 vs 7.25 years). We investigated the performance status of US equipment used in the clinical area in Daegu. The basis for the two items are not present this proposed passing standard. Equipment performance was associated with the number of years of using US equipment. It is necessary to maintain the best performance of the equipment phantom measurements for performance testing of US equipment.

  1. Equipment for nuclear medical centers, production capabilities of Rosatom enterprises

    International Nuclear Information System (INIS)

    Gavrish, Yu. N.; Koloskov, S. A.; Smirnov, V. P.; Strokach, A. P.

    2015-01-01

    Analysis of the capabilities of the State Corporation Rosatom enterprises on the development and production of diagnostic and therapeutic equipment for nuclear medicine centers is presented. Prospects of the development of accelerator equipment for the production of a wide range of radioisotope products are shown, and the trends of its development are determined. A comparative analysis of the technical parameters of domestic tomographs and devices for brachytherapy with foreign counterparts is given

  2. Equipment for nuclear medical centers, production capabilities of Rosatom enterprises

    Science.gov (United States)

    Gavrish, Yu. N.; Koloskov, S. A.; Smirnov, V. P.; Strokach, A. P.

    2015-12-01

    Analysis of the capabilities of the State Corporation Rosatom enterprises on the development and production of diagnostic and therapeutic equipment for nuclear medicine centers is presented. Prospects of the development of accelerator equipment for the production of a wide range of radioisotope products are shown, and the trends of its development are determined. A comparative analysis of the technical parameters of domestic tomographs and devices for brachytherapy with foreign counterparts is given.

  3. Medical equipment management through the use of radio frequency identification (RFID)

    OpenAIRE

    Sanchez, Joaquin A.; Nixon, Richard A.; Chávez, Sergio

    2004-01-01

    MBA Professional Report Approved for public release, distribution is unlimited The purpose of this MBA project is to identify the potential value of Radio Frequency Identification (RFID) use in the management of medical equipment at Naval Medical Center San Diego (NMCSD). In doing so, our project seeks to derive potential benefits through the use of RFID technology by comparing a group of medical equipment items that are tracked within NMCSD. The project includes a discussion of additio...

  4. Changes in IEC standards related to diagnostic radiology

    International Nuclear Information System (INIS)

    Porubszky, T.; Barsai, J.

    2007-01-01

    Complete test of publication follows. Purposes. Technical Committee TC62 of International Electrotechnical Commission (IEC) deals with medical electrical equipment (i.e. medical devices using electricity). Standardization concerning diagnostic radiology equipment is task of its Sub-Committee SC62B. An outlook of its activities and present situation, and especially of radiation protection aspects, is given. Materials and methods. Third edition of basic safety standard for medical electrical equipment IEC 60601-1 was issued in 2005. Elaboration of new collateral and particular standards - applicable together with it - is in progress. These standards are generally at the same time also European - EN - and national standards. There is a great importance of radiation protection in diagnostic X-ray equipment. Collateral standard IEC 6060-1-3 about it was at first issued in 1994. Rapid development of imaging technology demands updating of requirements. SC62B in 2003 founded a maintenance team MT37 for preparation of the second edition of this standard. According to new safety philosophy of IEC all modality specific requirements are to be collected in 'safety and essential performance' particular standards. A new working group WG42 - founded in 2006 - elaborates a new particular standard IEC 60601-2-54 for radiographic and radioscopic equipment. Maintenance team MT32 deals with safety and performance standards for X-ray tube assemblies. The authors actively participate in these activities. Results and discussion. Present and future system of diagnostic radiology IEC standards and some interesting details are presented. Conclusions. International standards - although they are not 'obligatory' - are generally the basis of safety and performance certification of diagnostic radiology equipment and often also of their quality assurance.

  5. Tacit knowledge and visual expertise in medical diagnostic reasoning: implications for medical education.

    Science.gov (United States)

    Heiberg Engel, Peter Johan

    2008-01-01

    Much education--especially at the university level--has been criticized for having primarily dealt with explicit knowledge, i.e. those aspects of mental activities, which are verbal and conscious. Furthermore, research in medical diagnostic reasoning has been criticized for having focused on the specialty of intern medicine, while specialties with other skills, i.e. perceptive skills within pathology and radiology, have been ignored. To show that the concept of tacit knowledge is important in medical education-at all levels and in medical diagnostic reasoning. Describing how tacit knowledge according to Michael Polany, is experienced and expressed in day-to-day life, it is shown that there is a tacit dimension to all knowledge. Reviewing recent literature on medical diagnostic reasoning, it is shown that tacit knowledge is recognized in connection with concepts such as "non-analytical reasoning" and "dual process of reasoning." It is important that educators are trained in how explicit and implicit knowledge is attained and that tacit knowledge is included in educational programmes of all medical specialties.

  6. Quality Control in Diagnostic Radiology in the Netherlands (invited paper)

    International Nuclear Information System (INIS)

    Zoetelief, J.

    1998-01-01

    Application of the general principles of radiation protection to medical diagnostic radiology implies that each procedure using X rays or radionuclides is to be justified and optimised. Optimisation in diagnostic radiology implies that the radiation burden to the patient should be as low as possible, but compatible with the image quality necessary to obtain an adequate diagnosis or to guide treatment. Quality control of equipment is a prerequisite for achieving optimisation in diagnostic radiology. This was especially recognised for mammography as employed for breast cancer screening. Existing legislation in the Netherlands includes only a few criteria for equipment used in diagnostic radiology. In addition, the criteria are not all operational and measurement methods are lacking. Therefore, upon the initiative of the Dutch Ministry of Health, Welfare and Sports, the relevant professional societies, in collaboration with the former TNO Centre for Radiological Protection and Dosimetry, formulated eleven guidelines for quality control of equipment used in diagnostic radiology, including test procedures, test frequencies and limiting values. The implementation of quality control of equipment was included in the 1984 European Directive (84/466/Euratom) laying down basic measures for the radiation protection of persons undergoing medical examination or treatment. In the most recent European Directive on medical exposure (97/43/Euratom) the importance of quality control is stressed. In addition, the latter EC directive proposes the use of diagnostic reference levels for limiting the risks for patients undergoing diagnostic radiology. In the Netherlands preliminary reference levels for various procedures employed in diagnostic radiology are suggested. Finally, methods applied in the Netherlands for assessment of image quality are discussed. (author)

  7. NRC Information Notice No. 93-01: Accuracy of motor-operated valve diagnostic equipment manufactured by Liberty Technologies

    International Nuclear Information System (INIS)

    Grimes, B.K.

    1993-01-01

    Most licensees rely on MOV diagnostic equipment to provide information on the thrust delivered by the motor actuator in opening or closing its valve. The various types of MOV diagnostic equipment estimate valve stem thrust using different parameters, such as displacement of the spring pack or strain in the stem, mounting bolts, or yoke. Liberty Technologies has developed MOV diagnostic equipment, referred to as the Valve Operation Test and Evaluation System (VOTES), that estimates the thrust needed to open or close a valve based on strain of the valve yoke. The VOTES equipment derives thrust from yoke strain that has been calibrated to stem thrust using measured diametral strain of the valve stem and nominal engineering material properties. On October 2, 1992, Liberty Technologies notified the NRC that it had determined that two new factors can affect the thrust values obtained with its equipment. Those factors involve (1) the possible use of improper stem material constants and (2) the failure to account for a torque effect when the VOTES equipment is calibrated by measuring strain in the threaded portion of the valve stem. Liberty Technologies provided information on performing manual calculations to address these factors and stated that its new software, Version 2.3, assists in performing corrections to the thrust data

  8. Diagnostic Medical Imaging in Pediatric Patients and Subsequent Cancer Risk.

    Science.gov (United States)

    Mulvihill, David J; Jhawar, Sachin; Kostis, John B; Goyal, Sharad

    2017-11-01

    The use of diagnostic medical imaging is becoming increasingly more commonplace in the pediatric setting. However, many medical imaging modalities expose pediatric patients to ionizing radiation, which has been shown to increase the risk of cancer development in later life. This review article provides a comprehensive overview of the available data regarding the risk of cancer development following exposure to ionizing radiation from diagnostic medical imaging. Attention is paid to modalities such as computed tomography scans and fluoroscopic procedures that can expose children to radiation doses orders of magnitude higher than standard diagnostic x-rays. Ongoing studies that seek to more precisely determine the relationship of diagnostic medical radiation in children and subsequent cancer development are discussed, as well as modern strategies to better quantify this risk. Finally, as cardiovascular imaging and intervention contribute substantially to medical radiation exposure, we discuss strategies to enhance radiation safety in these areas. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  9. [Development of a medical equipment support information system based on PDF portable document].

    Science.gov (United States)

    Cheng, Jiangbo; Wang, Weidong

    2010-07-01

    According to the organizational structure and management system of the hospital medical engineering support, integrate medical engineering support workflow to ensure the medical engineering data effectively, accurately and comprehensively collected and kept in electronic archives. Analyse workflow of the medical, equipment support work and record all work processes by the portable electronic document. Using XML middleware technology and SQL Server database, complete process management, data calculation, submission, storage and other functions. The practical application shows that the medical equipment support information system optimizes the existing work process, standardized and digital, automatic and efficient orderly and controllable. The medical equipment support information system based on portable electronic document can effectively optimize and improve hospital medical engineering support work, improve performance, reduce costs, and provide full and accurate digital data

  10. Diagnostic information management system for the evaluation of medical images

    Energy Technology Data Exchange (ETDEWEB)

    Higa, Toshiaki; Torizuka, Kanji; Minato, Kotaro; Komori, Masaru; Hirakawa, Akina

    1985-04-01

    A practical, small and low-cost diagnostic information management system has been developed for a comparative study of various medical imaging procedures, including ordinary radiography, X-ray computed tomography, emission computed tomography, and so forth. The purpose of the system is to effectively manage the original image data files and diagnostic descriptions during the various imaging procedures. A diagnostic description of each imaging procedure for each patient is made on a hand-sort punched-card with line-drawings and ordinary medical terminology and then coded and computerized using Index for Roentgen Diagnoses (American College of Radiology). A database management software (DB Master) on a personal computer (Apple II) is used for searching for patients' records on hand-sort punched-cards and finally original medical images. Discussed are realistic use of medical images and an effective form of diagnostic descriptions.

  11. Diagnostic information management system for the evaluation of medical images

    International Nuclear Information System (INIS)

    Higa, Toshiaki; Torizuka, Kanji; Minato, Kotaro; Komori, Masaru; Hirakawa, Akina.

    1985-01-01

    A practical, small and low-cost diagnostic information management system has been developed for a comparative study of various medical imaging procedures, including ordinary radiography, X-ray computed tomography, emission computed tomography, and so forth. The purpose of the system is to effectively manage the original image data files and diagnostic descriptions during the various imaging procedures. A diagnostic description of each imaging procedure for each patient is made on a hand-sort punched-card with line-drawings and ordinary medical terminology and then coded and computerized using Index for Roentgen Diagnoses (American College of Radiology). A database management software (DB Master) on a personal computer (Apple II) is used for searching for patients' records on hand-sort punched-cards and finally original medical images. Discussed are realistic use of medical images and an effective form of diagnostic descriptions. (author)

  12. IR IMAGING AND VIBRATORY METHODS OF CONTROL AND DIAGNOSTICS OF THE EQUIPMENT AT OJSC «BSW – MANAGEMENT COMPANY OF HOLDING «BMC»

    Directory of Open Access Journals (Sweden)

    A. S. Shinkarev

    2017-01-01

    Full Text Available The article discusses the main methods of diagnostics of the equipment of OJSC «BSW – management company of holding «BMC». Presents results of diagnostics of various equipment with the description of the devices directly used for the diagnostic that can detect various defects of the equipment at the stage of their origination. Describes the advantages of these methods compared to other methods of control and diagnostics.

  13. Comparison of Diagnostic Information from Regular Telemetry Equipment and a Novel Patch Type Electrocardiogram Recorder

    DEFF Research Database (Denmark)

    Saadi, Dorthe Bodholt; Egstrup, Kenneth; Hoppe, Karsten

    2014-01-01

    The purpose of this pilot study is to compare the diagnostic information obtained using regular telemetry equipment and the novel ePatch heart monitor. The comparison was conducted by a cardiologist on 24-hour recordings from 11 admitted patients. For all 11 recordings, the same diagnostic inform...

  14. [Hospital clinical engineer orientation and function in the maintenance system of hospital medical equipment].

    Science.gov (United States)

    Li, Bin; Zheng, Yunxin; He, Dehua; Jiang, Ruiyao; Chen, Ying; Jing, Wei

    2012-03-01

    The quantity of medical equipment in hospital rise quickly recent year. It provides the comprehensive support to the clinical service. The maintenance of medical equipment becomes more important than before. It is necessary to study on the orientation and function of clinical engineer in medical equipment maintenance system. Refer to three grade health care system, the community doctors which is called General practitioner, play an important role as the gatekeeper of health care system to triage and cost control. The paper suggests that hospital clinical engineer should play similar role as the gatekeeper of medical equipment maintenance system which composed by hospital clinical engineer, manufacture engineer and third party engineer. The hospital clinical engineer should be responsible of guard a pass of medical equipment maintenance quality and cost control. As the gatekeeper, hospital clinical engineer should take the responsibility of "General engineer" and pay more attention to safety and health of medical equipment. The responsibility description and future transition? development of clinical engineer as "General Engineer" is discussed. More attention should be recommended to the team building of hospital clinical engineer as "General Engineer".

  15. Vibrational methods of the overhead gas-pipelines technological equipment diagnostics

    International Nuclear Information System (INIS)

    Zakhezin, A.M.; Malysheva, T.V.

    2001-01-01

    The diagnostic methods of overhead gas-pipelines of the technical equipment of gas-compressor station are considered in this article by carrying out registration certification documentation. Some faults of overhead technical gas-pipelines have been proposed. This paper is devoted to the diagnostic methods of the whole gas- pipelines and their parts for some faults during expert checking fulfillment and carrying out registration certification documentation. The analysis of all defects allows to determine a 'between-repairs interval', to develop some operations to avoid these faults and to estimate the repair operation quality, to reduce failure probability. As an example of the effectiveness of technical condition service of vibrational methods by expertise fulfillment have been considered for some defects of the overhead pipelines. (author)

  16. Diagnostic imaging in undergraduate medical education: an expanding role

    International Nuclear Information System (INIS)

    Miles, K.A.

    2005-01-01

    Radiologists have been involved in anatomy instruction for medical students for decades. However, recent technical advances in radiology, such as multiplanar imaging, 'virtual endoscopy', functional and molecular imaging, and spectroscopy, offer new ways in which to use imaging for teaching basic sciences to medical students. The broad dissemination of picture archiving and communications systems is making such images readily available to medical schools, providing new opportunities for the incorporation of diagnostic imaging into the undergraduate medical curriculum. Current reforms in the medical curriculum and the establishment of new medical schools in the UK further underline the prospects for an expanding role for imaging in medical education. This article reviews the methods by which diagnostic imaging can be used to support the learning of anatomy and other basic sciences

  17. Primary Salvage Survey of the Interference of Radiowaves Emitted by Smartphones on Medical Equipment.

    Science.gov (United States)

    Takao, Hiroyuki; Yeh, Yu Chih; Arita, Hiroyuki; Obatake, Takumi; Sakano, Teppei; Kurihara, Minoru; Matsuki, Akira; Ishibashi, Toshihiro; Murayama, Yuichi

    2016-10-01

    Use of mobile phones has become a standard reality of everyday living for many people worldwide, including medical professionals, as data sharing has drastically helped to improve quality of care. This increase in the use of mobile phones within hospitals and medical facilities has raised concern regarding the influence of radio waves on medical equipment. Although comprehensive studies have examined the effects of electromagnetic interference from 2G wireless communication and personal digital cellular systems on medical equipment, similar studies on more recent wireless technologies such as Long Term Evolution, wideband code division multiple access, and high-speed uplink access have yet to be published. Numerous tests targeting current wireless technologies were conducted between December 2012 and March 2013 in an anechoic chamber, shielded from external radio signals, with a dipole antenna to assess the effects of smartphone interference on several types of medical equipment. The interference produced by electromagnetic waves across five frequency bands from four telecommunication standards was assessed on 49 components from 22 pieces of medical equipment. Of the 22 pieces of medical equipment tested, 13 experienced interference at maximum transmission power. In contrast, at minimum transmission power, the maximum interference distance varied from 2 to 5 cm for different wireless devices. Four machines were affected at the minimum transmission power, and the maximum interference distance at the maximum transmission power was 38 cm. Results show that the interference from smartphones on medical equipment is very controllable.

  18. Tacit knowledge and visual expertise in medical diagnostic reasoning: implications for medical education

    DEFF Research Database (Denmark)

    Heiberg Engel, Peter Johan

    2008-01-01

    BACKGROUND: Much education--especially at the university level--has been criticized for having primarily dealt with explicit knowledge, i.e. those aspects of mental activities, which are verbal and conscious. Furthermore, research in medical diagnostic reasoning has been criticized for having...... focused on the specialty of intern medicine, while specialties with other skills, i.e. perceptive skills within pathology and radiology, have been ignored. AIMS: To show that the concept of tacit knowledge is important in medical education-at all levels and in medical diagnostic reasoning. METHODS...... such as "non-analytical reasoning" and "dual process of reasoning." CONCLUSION: It is important that educators are trained in how explicit and implicit knowledge is attained and that tacit knowledge is included in educational programmes of all medical specialties....

  19. Integrated software system for improving medical equipment management.

    Science.gov (United States)

    Bliznakov, Z; Pappous, G; Bliznakova, K; Pallikarakis, N

    2003-01-01

    The evolution of biomedical technology has led to an extraordinary use of medical devices in health care delivery. During the last decade, clinical engineering departments (CEDs) turned toward computerization and application of specific software systems for medical equipment management in order to improve their services and monitor outcomes. Recently, much emphasis has been given to patient safety. Through its Medical Device Directives, the European Union has required all member nations to use a vigilance system to prevent the reoccurrence of adverse events that could lead to injuries or death of patients or personnel as a result of equipment malfunction or improper use. The World Health Organization also has made this issue a high priority and has prepared a number of actions and recommendations. In the present workplace, a new integrated, Windows-oriented system is proposed, addressing all tasks of CEDs but also offering a global approach to their management needs, including vigilance. The system architecture is based on a star model, consisting of a central core module and peripheral units. Its development has been based on the integration of 3 software modules, each one addressing specific predefined tasks. The main features of this system include equipment acquisition and replacement management, inventory archiving and monitoring, follow up on scheduled maintenance, corrective maintenance, user training, data analysis, and reports. It also incorporates vigilance monitoring and information exchange for adverse events, together with a specific application for quality-control procedures. The system offers clinical engineers the ability to monitor and evaluate the quality and cost-effectiveness of the service provided by means of quality and cost indicators. Particular emphasis has been placed on the use of harmonized standards with regard to medical device nomenclature and classification. The system's practical applications have been demonstrated through a pilot

  20. 42 CFR 410.38 - Durable medical equipment: Scope and conditions.

    Science.gov (United States)

    2010-10-01

    ... or purchase of durable medical equipment, including iron lungs, oxygen tents, hospital beds, and wheelchairs, if the equipment is used in the patient's home or in an institution that is used as a home. (b... vehicle whose steering is operated by an electronic device or a joystick to control direction and turning...

  1. A recommender system for medical imaging diagnostic.

    Science.gov (United States)

    Monteiro, Eriksson; Valente, Frederico; Costa, Carlos; Oliveira, José Luís

    2015-01-01

    The large volume of data captured daily in healthcare institutions is opening new and great perspectives about the best ways to use it towards improving clinical practice. In this paper we present a context-based recommender system to support medical imaging diagnostic. The system relies on data mining and context-based retrieval techniques to automatically lookup for relevant information that may help physicians in the diagnostic decision.

  2. Radiological protection and quality control for diagnostic radiology in China

    International Nuclear Information System (INIS)

    Baorong, Yue

    2008-01-01

    Full text: There are 43,000 diagnostic departments, nearly 70,000 X-ray diagnostic facilities, 7,000 CT, 250 million for the annual total numbers of X-ray examinations, 120,000 occupationally exposed workers in diagnostic radiology. 'Basic standards for protection against ionizing radiation and for the safety of radiation sources' is promulgated on October, 2002. This basic standard follows the BSS. 'Rule on the administration of radio-diagnosis and radiotherapy', as a order of the Ministry of Health No. 46, is promulgated by Minister of Health on January 24, 2006. It includes general provisions, requirements and practice, establishment and approval of radio-diagnosis and radiotherapy services, safeguards and quality assurance, and so on. There are a series of radiological protection standards and quality control standards in diagnostic radiology, including 'radiological protection standard for the examination in X-ray diagnosis', 'radiological health protection standards for X-ray examination of child-bearing age women and pregnant women', 'radiological protection standards for the children in X-ray diagnosis', 'standards for radiological protection in medical X-ray diagnosis', 'specification for radiological protection monitoring in medical X-ray diagnosis', 'guide for reasonable application of medical X-ray diagnosis', 'general aspects for quality assurance in medical X-ray image of diagnosis', 'specification of image quality control test for the medical X-ray diagnostic equipment', 'specification of image quality assurance test for X-ray equipment for computed tomography', 'specification for testing of quality control in computed radiography (CR)' and 'specification for testing of quality control in X-ray mammography'. With the X-ray diagnostic equipment, there are acceptant tests, status tests and routing tests in large hospitals. It is poor for routing test in middle and smaller hospitals. CT is used widely in diagnostic radiology, however most workers in CT

  3. Results of evaluation of quality control measurement instrument of x-ray diagnostic equipment by non-invasive method

    International Nuclear Information System (INIS)

    Laan, Flavio T. van der; Elbern, Alvin W.

    1996-01-01

    This work shows the results of the tests realized on Santa Rita Hospital (Porto Alegre), using a non invasive quality control measurement instrument, developed in this University for fast measurement of essential parameters of X-rays diagnostic equipment. In the tests we used a diagnostics Siemens X ray, model Heliofos 4E as our standard equipment. The linearity test of sensor probe and the exposure rate calibration was performed, with a Palmer Dosimeter. For the kVp and exposure time we used a RTI commercial instrument. (author)

  4. Radionuclide diagnostics in St. Petersburg: сurrent status and development challenges

    Directory of Open Access Journals (Sweden)

    I. A. Zvonova

    2015-01-01

    Full Text Available This work aims at radionuclide diagnostics analyses in the Russian Federation city of St. Petersburg over 2005–2014. The study covers trends and development challenges , availability of radionuclide diagnostics for population needs, exposure doses for patients.This work aims at radionuclide diagnostics analyses in the Russian Federation city of St. Petersburg over 2005–2014. The study covers trends and development challenges , availability of radionuclide diagnostics for population needs, exposure doses for patients.Materials and methods. The radionuclide diagnostics temporal and structural changes’ analysis was based on Federal state statistical observation forms No.3-DOZ for St. Petersburg and on the results of radionuclide diagnostics subdivision surveys with radiology physicians’ questionnaires on the amount and composition of conducted examinations, dosages of introduced radioactivity of radiopharmaceticals and patients’ doses.The results. Since the end of 1990s until 2012 the amount of radionuclide diagnostics procedures had been steadily reducing. 74000 procedures were conducted in 2005 and 35500 in 2012. The number of radionuclide diagnostics procedures per one thousand residents reduced from 16 to 7.2. Both indicators slightly grew in 2013. In 2014 the total number of radiodiagnostic proceduress amounted up to 42000 and 8.2 tests per 1000 residents. Since 2011 the diagnostic equipment was upgraded. Four medical institutions received SPECT (single photon emission computed tomography or SPECT/CT, two new PET ( positron emission tomographs – centers were set up, three medical institutions had acquired positron emission tomographs (PET and are conducting PET – diagnostics receiving radiofarmaceuticals from external PET – center. At the same time one a third of radiodiagnostic units still has been operating obsolete and depreciated equipment dating back to 1980–1990 .Inspection results indicated that St. Petersburg

  5. Decision Support Procedure for Medical Equipment Maintenance Management

    NARCIS (Netherlands)

    Masmoudi, Malek; Houria, Zeineb Ben; Al Hanbali, Ahmad; Masmoudi, Faouzi

    2016-01-01

    Hospitals outsource several activities of the service support in order to focus on the core healthcare production as maintenance service. Recently, faced to the sophistication and the costs of medical equipment that continue to escalate, governments have implemented new reforms to control costs and

  6. The study of practices in planed diagnostic medical exposure

    International Nuclear Information System (INIS)

    Popescu, Irina-Anca; Perju, Nicoleta Ana-Maria; Cobzeanu, Camelia

    2011-01-01

    The exposure of population to ionizing radiations in medical diagnostic purposes represents a planed exposure procedure, medically justified, having a direct impact on patient health state. A justification of exposure, with a result that can confirm a clinical diagnostic, implies further important steps in treatment decisions. Optimization in patients radiological protection is the result of observing the reference levels recommendations, which maintains a reasonable individual exposure to ionizing radiation in medical purpose. In this paper we investigated the justification of 4189 exposures of patients who underwent planed diagnostic medical investigation over 36 months in a radiological unit. The most frequent investigation concerned the spinal column in 38.3% of total exposures-mainly at lumbar level (63.0% and 24.1%, respectively of total number of exposures), followed by limb bones (20.6%) and thorax (26.9%). Justification of practices included: rheumatic pains in 45.8% of exposures followed by traumatic injuries (20.6%), pleural and pulmonary pathology (19.3%), malignant processes (12.3%), ear-nose-throat investigations (1.1%) and car accidents (0.9%). The females over 40 years old were the group with the highest number of medical exposures, with 54.5% of total practices. This study revealed that the number of medical exposures justification is almost equal with non-justified examinations, confirming a not so good correlation between clinical diagnostic and the required radiological investigation. The percentages of justified versus non-justified practices indicated by specialist physicians and general practitioners were slightly equal - 59.3% vs. 40.7%, 56.9% vs. 43.1%, respectively. The analysis of data concluded that either specialist/general physicians must evaluate more rigorously the patients and all clinical signs in order to reduce as reasonable as possible the non-justified medical exposures to ionizing radiations, and thus to avoid financial and

  7. Osseous Metastase of Occult Paraganglioma: A Diagnostic Medical Error

    Directory of Open Access Journals (Sweden)

    Ghasemi TA

    2013-10-01

    Full Text Available Introduction: Diagnostic errors have a natural complexity. Medical diagnoses make up a large proportion of all medical errors and cause much suffering and harm. Compared to other types of error, diagnostic errors receive little attention-a major factor in continuity of unacceptable rates of diagnostic error. Case: A 55-year-old woman presented to the emergency department (ED complaining of bone pain which has been started a month ago and increased gradually in the upper right thigh. Following the emergency evaluation she was sent home with pain medication. On the second visit, a femur neck fracture was seen in the x-ray. She underwent hemiarthroplasty and was discharged. Over several weeks she was reevaluated by many Physicians, because of her worsening pain .In the third visit after the surgery, her x-ray showed bone destruction and following bone biopsy, malignant paraganglioma was diagnosed. Discussion and solution: In all cases in which patient comes to us with skeletal pain, getting a comprehensive history and a full physical examination are prior to lab tests and x-rays. Bone metastasis which can develop severe pain and pathological fractures, is common in patients with malignant paraganglioma. Effective steps for diagnostic error prevention are: Considering the diagnostic error in the normal range of quality assurance surveillance and review, identifying the elements leading to diagnostic errors and getting feedback on the diagnoses Physicians make, in order to improve their skills. Conclusion: It is an every health system priority to identify, analyze, and prevent diagnostic errors in order to improve patient safety

  8. Moving beyond quality control in diagnostic radiology and the role of the clinically qualified medical physicist.

    Science.gov (United States)

    Delis, H; Christaki, K; Healy, B; Loreti, G; Poli, G L; Toroi, P; Meghzifene, A

    2017-09-01

    Quality control (QC), according to ISO definitions, represents the most basic level of quality. It is considered to be the snapshot of the performance or the characteristics of a product or service, in order to verify that it complies with the requirements. Although it is usually believed that "the role of medical physicists in Diagnostic Radiology is QC", this, not only limits the contribution of medical physicists, but is also no longer adequate to meet the needs of Diagnostic Radiology in terms of Quality. In order to assure quality practices more organized activities and efforts are required in the modern era of diagnostic radiology. The complete system of QC is just one element of a comprehensive quality assurance (QA) program that aims at ensuring that the requirements of quality of a product or service will consistently be fulfilled. A comprehensive Quality system, starts even before the procurement of any equipment, as the need analysis and the development of specifications are important components under the QA framework. Further expanding this framework of QA, a comprehensive Quality Management System can provide additional benefits to a Diagnostic Radiology service. Harmonized policies and procedures and elements such as mission statement or job descriptions can provide clarity and consistency in the services provided, enhancing the outcome and representing a solid platform for quality improvement. The International Atomic Energy Agency (IAEA) promotes this comprehensive quality approach in diagnostic imaging and especially supports the field of comprehensive clinical audits as a tool for quality improvement. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  9. Nano structures for Medical Diagnostics Md

    International Nuclear Information System (INIS)

    Bellah, M.; Iqbal, S.M.; Bellah, M.; Iqbal, S.M.; Christensen, S.M.; Iqbal, S.M.; Iqbal, S.M.

    2012-01-01

    Nano technology is the art of manipulating materials on atomic or molecular scales especially to build nano scale structures and devices. The field is expanding quickly, and a lot of work is ongoing in the design, characterization, synthesis, and application of materials, structures, devices, and systems by controlling shape and size at nanometer scale. In the last few years, much work has been focused on the use of nano structures toward problems of biology and medicine. In this paper, we focus on the application of various nano structures and nano devices in clinical diagnostics and detection of important biological molecules. The discussion starts by introducing some basic techniques of micro-/nano scale fabrication that have enabled reproducible production of nano structures. The prospects, benefits, and limitations of using these novel techniques in the fields of bio detection and medical diagnostics are then discussed. Finally, the challenges of mass production and acceptance of nano technology by the medical community are considered.

  10. Exploring the Case for a Global Alliance for Medical Diagnostics Initiative

    Directory of Open Access Journals (Sweden)

    Melissa L. Mugambi

    2017-01-01

    Full Text Available In recent years, the private and public sectors have increased investments in medical diagnostics for low- and middle-income countries (LMICs. Despite these investments, numerous barriers prevent the adoption of existing diagnostics and discourage the development and introduction of new diagnostics in LMICs. In the late 1990s, the global vaccine community had similar challenges, as vaccine coverage rates stagnated and the introduction of new vaccines was viewed as a distraction to delivering existing vaccines. To address these challenges, the international community came together and formed the Global Alliance for Vaccines Initiative (GAVI. Sixteen years after the formation of GAVI, we see evidence of a healthier global vaccine landscape. We discuss how GAVI’s four guiding principles (product, health systems strengthening, financing and market shaping might apply to the advancement of medical diagnostics in LMICs. We present arguments for the international community and existing organizations to establish a Global Alliance for Medical Diagnostics Initiative (GAMDI.

  11. Supporting management of medical equipment for inpatient service in public hospitals: a case study.

    Science.gov (United States)

    Figueroa, Rosa L; Vallejos, Guido E

    2013-01-01

    This work presents a study of medical equipment availability in the short and long term. The work is divided in two parts. The first part is an analysis of the medical equipment inventory for the institution of study. We consider the replacement, maintenance, and reinforcement of the available medical equipment by considering local guidelines and surveying clinical personnel appreciation. The resulting recommendation is to upgrade the current equipment inventory if necessary. The second part considered a demand analysis in the short and medium term. We predicted the future demand with a 5-year horizon using Holt-Winters models. Inventory analysis showed that 27% of the medical equipment in stock was not functional. Due to this poor performance result we suggested that the hospital gradually addresses this situation by replacing 29 non-functional equipment items, reinforcing stock with 40 new items, and adding 11 items not available in the inventory but suggested by the national guidelines. The results suggest that general medicine inpatient demand has a tendency to increase within the time e.g. for general medicine inpatient service the highest increment is obtained by respiratory (12%, RMSE=8%) and genitourinary diseases (20%, RMSE=9%). This increment did not involve any further upgrading of the proposed inventory.

  12. The tendency of medical electrical equipment - IEC 60601-2-54: Particular requirements for the basic safety and essential performance of x-ray equipment for radiography and radioscopy

    International Nuclear Information System (INIS)

    Roh, Young Hoon; Kim, Jung Min

    2015-01-01

    Medical electrical equipment - Part 1: General requirement for basic safety and essential performance of MFDS was revised as 3th edition and Medical electrical equipment Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment will be expected to be announced as notification. Therefore this technical report was written to introduce provision of the particular requirements, replacement, addition, amendment. The purpose of this particular requirements is to secure requirements for basic safety and essential performance of X-ray equipment for radiography and radioscopy. X-ray high voltage generator, mechanical protective device, protection against radiation is included in this particular requirements. Medical electrical equipment - Part 1, Part 1-2, Part 1-3 is applied to this particular requirements. If the requirements is announced as notification, It is expected to widen understanding for basic safety and essential performance of X-ray equipment for radiography and radioscopy and play a part to internationalize of medical equipment

  13. The Use of Nanomaterials and Microfluidics in Medical Diagnostics

    DEFF Research Database (Denmark)

    Ashley, Jon; Sun, Yi

    2018-01-01

    and manipulation of materials, systems, and devices at the nanometer scale. The development of nanomaterials and nano-devices can be classified into two general approaches. The top down approach deals exclusively with developing nanostructures through machining, templating and lithographic techniques and refers...... nanotechnology followed by a brief summary of bottom-up approaches to developing nanomaterials and their use in medical diagnostics. Then a discussion on the top-down approach will focus on nano-devices, methods for fabrication and the applications of these devices in medical diagnostics. The chapter will go...

  14. In-flight medical emergencies during airline operations: a survey of physicians on the incidence, nature, and available medical equipment

    Directory of Open Access Journals (Sweden)

    Hinkelbein J

    2017-02-01

    Full Text Available Jochen Hinkelbein,1,2 Christopher Neuhaus,2,3 Lennert Böhm,1 Steffen Kalina,1 Stefan Braunecker1,2 1Department of Anaesthesiology and Intensive Care Medicine, University Hospital of Cologne, Cologne, 2Working group “Emergency Medicine and Air Rescue”, German Society for Aviation and Space Medicine (DGLRM, Munich, 3Department of Anesthesiology, Heidelberg University Hospital, Heidelberg, Germany Background: Data on the incidence of in-flight medical emergencies on-board civil aircraft are uncommon and rarely published. Such data could provide information regarding required medical equipment on-board aircraft and requisite training for cabin crew. The aim of the present study was to gather data on the incidences, nature, and medical equipment for in-flight medical emergencies by way of a survey of physician members of a German aerospace medical society.Materials and methods: Using unipark.de (QuestBack GmbH, Cologne, Germany, an online survey was developed and used to gather specific information. Members of the German Society for Aviation and Space Medicine (Deutsche Gesellschaft für Luft- und Raumfahrtmedizin e.V.; DGLRM were invited to participate in the survey during a 4-week period (21 March 2015 to 20 April 2015. Chi-square test was used for statistical analysis (p<0.05 was considered significant.Results: Altogether, 121 members of the society responded to the survey (n=335 sent out. Of the 121 respondents, n=54 (44.6% of the participants (89.9% male and 10.1% female; mean age, 54.1 years; n=121 were involved in at least one in-flight medical emergency. Demographic parameters in this survey were in concordance with the society members’ demographics. The mean duration of flights was 5.7 hours and the respondents performed 7.1 airline flights per year (median. Cardiovascular (40.0% and neurological disorders (17.8% were the most frequent diagnoses. The medical equipment (78.7% provided was sufficient. An emergency diversion was

  15. Proceedings on US-Japan workshop A-56 'irradiation effects on plasma diagnostic equipment'

    International Nuclear Information System (INIS)

    1986-06-01

    This is a collection of abstracts and papers for the US-Japan Workshop A-56 on ''Irradiation Effects on Plasma Diagnostic Equipments'' held at the Institute of Plasma Physics, Nagoya University, on January 28 through 30, 1986. The topics presented at the workshop are classified as follows: 1) Definition of the problems and general views. 2) Radiation levels estimated from recent experiments and analysis on large tokamaks. 3) Radiation sensitivities of diagnostic components. 4) Neutron sources for irradiation testing. 5) Discussion on suggested experiments on radiation hardening and conclusions. The conclusions summarized by Dr. K. M. Young are also included. (author)

  16. CRC Handbook of Medical Physics, vol. 3

    International Nuclear Information System (INIS)

    Waggener, R.G.; Kereiakes, J.G.; Shalek, R.J.

    1984-01-01

    In this work, the care and testing of measurement and diagnostic instruments are described in detail. Difficulties encountered with therapeutic and diagnostic calibrations are explored and solutions are suggested. VOLUME III Physics Teaching for Radiologic Technologists, Physics Teaching for Diagnostic Radiology Residents, Physics Teaching for Nuclear Medicine Residents, Physics Teaching for Radiotherapy Residents, Degree Programs in Medical Physics, Radiobiology Teaching, Non-Degree Medical Physics Training and American Board of Radiology Certifications, Radioactivity and Production of Medical Isotopes, Practical Medical Physics Consulting, Radiologic Terminology, Nuclear Medicine Imaging Techniques, Description of Radiotherapy Procedures, Medical Applications of Ultrasonography and Thermography, Glossary of Medical and Anatomical Terms Used in Medical Physics, Equipment List for Medical Physics and Acquisition Priority. Bibliography of Reference Materials. Index

  17. Radiation protection type testing and licensing of diagnostic X-ray equipment in the GDR

    International Nuclear Information System (INIS)

    Taschner, P.; Poulheim, K.F.; Feldheim, W.

    1987-01-01

    The results of more than 10 years experience in type testing and type licensing of diagnostic X-ray equipment with respect to meeting radiation protection requirements as well as the implications for the conduct of these procedures resulting from the introduction of new radiation protection legislation in 1983 and 1984, are described. At present an updated version of the 'Regulation of 16 December 1977 concerning radiation protection type testing and licensing of sealed radiation sources and equipment emitting ionizing radiation' is being prepared. (author)

  18. Computational Diagnostic: A Novel Approach to View Medical Data.

    Energy Technology Data Exchange (ETDEWEB)

    Mane, K. K. (Ketan Kirtiraj); Börner, K. (Katy)

    2007-01-01

    A transition from traditional paper-based medical records to electronic health record is largely underway. The use of electronic records offers tremendous potential to personalize patient diagnosis and treatment. In this paper, we discuss a computational diagnostic tool that uses digital medical records to help doctors gain better insight about a patient's medical condition. The paper details different interactive features of the tool which offer potential to practice evidence-based medicine and advance patient diagnosis practices. The healthcare industry is a constantly evolving domain. Research from this domain is often translated into better understanding of different medical conditions. This new knowledge often contributes towards improved diagnosis and treatment solutions for patients. But the healthcare industry lags behind to seek immediate benefits of the new knowledge as it still adheres to the traditional paper-based approach to keep track of medical records. However recently we notice a drive that promotes a transition towards electronic health record (EHR). An EHR stores patient medical records in digital format and offers potential to replace the paper health records. Earlier attempts of an EHR replicated the paper layout on the screen, representation of medical history of a patient in a graphical time-series format, interactive visualization with 2D/3D generated images from an imaging device. But an EHR can be much more than just an 'electronic view' of the paper record or a collection of images from an imaging device. In this paper, we present an EHR called 'Computational Diagnostic Tool', that provides a novel computational approach to look at patient medical data. The developed EHR system is knowledge driven and acts as clinical decision support tool. The EHR tool provides two visual views of the medical data. Dynamic interaction with data is supported to help doctors practice evidence-based decisions and make judicious

  19. Performance of on-site Medical waste disinfection equipment in hospitals of Tabriz, Iran

    Directory of Open Access Journals (Sweden)

    Hassan Taghipour

    2016-10-01

    Full Text Available Background: The number of studies available on the performance of on-site medical waste treatment facilities is rare, to date. The aim of this study was to evaluate the performance of onsite medical waste treatment equipment in hospitals of Tabriz, Iran. Methods: A various range of the on-site medical waste disinfection equipment (autoclave, chemical disinfection, hydroclave, and dry thermal treatment was considered to select 10 out of 22 hospitals in Tabriz to be included in the survey. The apparatus were monitored mechanically, chemically, and biologically for a six months period in all of the selected hospitals. Results: The results of the chemical monitoring (Bowie-Dick tests indicated that 38.9% of the inspected autoclaves had operational problems in pre-vacuum, air leaks, inadequate steam penetration into the waste, and/or vacuum pump. The biological indicators revealed that about 55.55% of the samples were positive. The most of applied devices were not suitable for treating anatomical, pharmaceutical, cytotoxic, and chemical waste. Conclusion: Although on-site medical waste treating facilities have been installed in all the hospitals, the most of infectious-hazardous medical waste generated in the hospitals were deposited into a municipal solid waste landfill, without enough disinfection. The responsible authorities should stringently inspect and evaluate the operation of on-site medical waste treating equipment. An advanced off-site central facility with multi-treatment and disinfection equipment and enough capacity is recommended as an alternative.

  20. The study on the perceptions of radiological technologist in medical imaging equipment used by the oriental doctor

    International Nuclear Information System (INIS)

    Choi, Jae Ho; Kang, Gi Bong; Kim, Sang Hyun

    2017-01-01

    In order to examine how Radiological Technologists perceive the oriental doctor's use of Medical Imaging Equipment, surveys were conducted for the members of the Korean Radiological Technologists Association. The total number of respondents were 515 and 481, with 34 insincere responses removed caused of nonvalidated answer. The results of the analysis are as follows. Although there were no statistical significance in the difference in perception by location of residence, work place, and educational background, respondents with higher education showed a tendency to agree on the use of comprehensive medical imaging equipment, but tended to oppose the use of special medical imaging equipment. Differences in perception by gender showed a greater negative perception toward the oriental doctor's use of medical imaging equipment by women than men. In particular, women showed more negative tendency for oriental doctor's use of special medical imaging equipment such as MRI, CT, and ultrasound equipment compared to men, and this was statistically significant. The difference in perception by age showed that the oriental doctor's use of medical imaging equipment was negative in the 20∼30s, neutral in the 40∼50s, and positive in the 60s, which were statistically significant. The difference in perception by work experience showed that the longer the work experience was, the more positive it was toward oriental doctor's use of medical imaging equipment. Specifically, the most favorable tendency was found with work experience of more than 30 years, which was statistically significant. The results of this study revealed the Radiological Technologists' perceptions on the oriental doctor's use of Medical Imaging Equipment and this can contribute to the direction of public health promotion in the future

  1. BIOANALYTICAL STANDARDIZING FOR SEROLOGICAL DIAGNOSTIC MEDICAL DEVICES

    OpenAIRE

    A. Yu. Galkin; A. G. Komar; A. A. Grigorenko

    2015-01-01

    In article we analyzed national and international regulations concerning the quality and safety of medical devices for in vitro diagnostics. We discussed the possibility of a partial application of the recommendations of the State Pharmacopoeia of Ukraine to this type of product. The main guiding regulatory documents establishing requirements for quality and safety tools for the serological diagnosis products are The technical regulation on medical devices for the diagnosis in vitro, DSTU ISO...

  2. Medical diagnostics with mobile devices: Comparison of intrinsic and extrinsic sensing.

    Science.gov (United States)

    Kwon, L; Long, K D; Wan, Y; Yu, H; Cunningham, B T

    2016-01-01

    We review the recent development of mobile detection instruments used for medical diagnostics, and consider the relative advantages of approaches that utilize the internal sensing capabilities of commercially available mobile communication devices (such as smartphones and tablet computers) compared to those that utilize a custom external sensor module. In this review, we focus specifically upon mobile medical diagnostic platforms that are being developed to serve the need in global health, personalized medicine, and point-of-care diagnostics. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Evaluation of conventional x-ray diagnostic equipment and radiological protection systems of hospitals and clinics installed in Recife city, Brazil

    International Nuclear Information System (INIS)

    Passos, Robson Silva

    1999-05-01

    Diagnostic radiology is the main contributor to the man-made exposure of general population. Since Quality Assurance (QA) programs ensure high quality diagnostic images with the lowest possible radiation dose to the patient, it has been recommended that all introduce QA programs for their radiological facilities. Consequently it is important to check the adequacy of equipment operating parameters in diagnostic radiography facilities, to ensure that a high quality of service is delivered. The purpose of this study was to evaluate the operating conditions of diagnostic units installed in Recife, Pernambuco. The study included 31 X-ray units from both public and private diagnostic services. The following parameters were evaluated: coincidence between the luminous and radiation fields; alignment of the radiation beam; agreement between the real and preset values of kVp and exposure time; filtration; half value lower (HVL); luminance of the view box; uniformity of the luminance; illuminance of the environment. The results showed that 20% of the equipment surveyed exhibited discrepancies between the luminous and radiation fields greater than 2% of the source to skin distance. The test of kilovoltage showed that 48% of the units do not fulfill the acceptability criteria, presenting discrepancies higher than ± 10% between the measured and preset values. The results of the accuracy of the timer indicated that 81% of the equipment surveyed present a discrepancy greater than ± 10% between the time selected in the control panel and actual exposure time.The test of the filtration shown that, in 20% of the equipment, this was inferior to 2,5 mm Al. The test of the luminance of view box shown that 96% of the equipment, shown a luminance lower of 2.000 cd/m 2 . Related to the test of the uniformity of the luminance, 81 % of the equipment shown a variation of the uniformity higher then 10%. The test of the iluminancy of the environment shown that 61 % of the equipment presented

  4. Mapping the different methods adopted for diagnostic imaging instruction at medical schools in Brazil.

    Science.gov (United States)

    Chojniak, Rubens; Carneiro, Dominique Piacenti; Moterani, Gustavo Simonetto Peres; Duarte, Ivone da Silva; Bitencourt, Almir Galvão Vieira; Muglia, Valdair Francisco; D'Ippolito, Giuseppe

    2017-01-01

    To map the different methods for diagnostic imaging instruction at medical schools in Brazil. In this cross-sectional study, a questionnaire was sent to each of the coordinators of 178 Brazilian medical schools. The following characteristics were assessed: teaching model; total course hours; infrastructure; numbers of students and professionals involved; themes addressed; diagnostic imaging modalities covered; and education policies related to diagnostic imaging. Of the 178 questionnaires sent, 45 (25.3%) were completed and returned. Of those 45 responses, 17 (37.8%) were from public medical schools, whereas 28 (62.2%) were from private medical schools. Among the 45 medical schools evaluated, the method of diagnostic imaging instruction was modular at 21 (46.7%), classic (independent discipline) at 13 (28.9%), hybrid (classical and modular) at 9 (20.0%), and none of the preceding at 3 (6.7%). Diagnostic imaging is part of the formal curriculum at 36 (80.0%) of the schools, an elective course at 3 (6.7%), and included within another modality at 6 (13.3%). Professors involved in diagnostic imaging teaching are radiologists at 43 (95.5%) of the institutions. The survey showed that medical courses in Brazil tend to offer diagnostic imaging instruction in courses that include other content and at different time points during the course. Radiologists are extensively involved in undergraduate medical education, regardless of the teaching methodology employed at the institution.

  5. The study on the perceptions of radiological technologist in medical imaging equipment used by the oriental doctor

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jae Ho [Dept. of Radiological Technology, Ansan University, Ansan (Korea, Republic of); Kang, Gi Bong [Dept. of Radiology, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Sang Hyun [Dept. of Radiology, Shinhan University, Seongnam (Korea, Republic of); and others

    2017-03-15

    In order to examine how Radiological Technologists perceive the oriental doctor's use of Medical Imaging Equipment, surveys were conducted for the members of the Korean Radiological Technologists Association. The total number of respondents were 515 and 481, with 34 insincere responses removed caused of nonvalidated answer. The results of the analysis are as follows. Although there were no statistical significance in the difference in perception by location of residence, work place, and educational background, respondents with higher education showed a tendency to agree on the use of comprehensive medical imaging equipment, but tended to oppose the use of special medical imaging equipment. Differences in perception by gender showed a greater negative perception toward the oriental doctor's use of medical imaging equipment by women than men. In particular, women showed more negative tendency for oriental doctor's use of special medical imaging equipment such as MRI, CT, and ultrasound equipment compared to men, and this was statistically significant. The difference in perception by age showed that the oriental doctor's use of medical imaging equipment was negative in the 20∼30s, neutral in the 40∼50s, and positive in the 60s, which were statistically significant. The difference in perception by work experience showed that the longer the work experience was, the more positive it was toward oriental doctor's use of medical imaging equipment. Specifically, the most favorable tendency was found with work experience of more than 30 years, which was statistically significant. The results of this study revealed the Radiological Technologists' perceptions on the oriental doctor's use of Medical Imaging Equipment and this can contribute to the direction of public health promotion in the future.

  6. Algorithms for diagnostics of the measuring channels and technological equipment at NPP with WWER-1000

    International Nuclear Information System (INIS)

    Vysotskij, V.G.

    1997-01-01

    An algorithm for diagnostics of the state of measuring channels of an information computer system with usage of analysis of statistical channel characteristics is presented. An algorithm for testing the generalized state of the NPP technological equipment is proposed

  7. Regulation E 67-13. Opinion of acceptance for the clinical use of medical equipment using radiation

    International Nuclear Information System (INIS)

    2015-01-01

    The objective of this regulation is to establish the regulatory requirements for the granting of the 'Act of Acceptance for the clinical use of radiation Medical Equipment employing' complementing the provisions of the 'Regulations for the Evaluation and State Control of Medical Equipment' and aims help to improve the legal basis of the Regulatory technical Medical Equipment Program. The provisions of this regulation is aimed at any institution of the National Health System, hereinafter applicant required an Opinion of Acceptance for the clinical use of a medical team that uses radiation to authorization of use in humans.

  8. [Current Situation and Prospects of Emergency Medical Equipment in Our Country].

    Science.gov (United States)

    Qi, Lijing; Cheng, Feng

    2016-03-01

    This article analyzes the new demand of emergency medical equipment in the current development trend based on the analysis of the development and current situation of emergency medicine in our country. At the same time it introduces the current industrial characteristics of our country. Finally it analyzes the development trend of this kind of equipment in the new emergency medicine field.

  9. Ordering of diagnostic information in encoded medical images. Accuracy progression

    Science.gov (United States)

    Przelaskowski, A.; Jóźwiak, R.; Krzyżewski, T.; Wróblewska, A.

    2008-03-01

    A concept of diagnostic accuracy progression for embedded coding of medical images was presented. Implementation of JPEG2000 encoder with a modified PCRD optimization algorithm was realized and initially verified as a tool for accurate medical image streaming. Mean square error as a distortion measure was replaced by other numerical measures to revise quality progression according to diagnostic importance of successively encoded image information. A faster increment of image diagnostic importance during reconstruction of initial packets of code stream was reached. Modified Jasper code was initially tested on a set of mammograms containing clusters of microcalcifications and malignant masses, and other radiograms. Teleradiologic applications were considered as the first area of interests.

  10. Ionizing radiation used in medical diagnostics as a source of radiation exposure of the patient with occupational diseases. Analysis and problems

    International Nuclear Information System (INIS)

    Apostolova, D.B.; Paskalev, Z.D.

    2001-01-01

    X-rays in medical diagnostic are the major source of Bulgarian population exposure to ionizing radiations. Diagnostic X-ray is the most diagnostic application and is used in a wide variety of examinations. The modern concept for radiation protection of patients in diagnostic radiology is based on two main principles: justification of the examinations and radiation protection optimization. It is pointed out that the collective effective dose of radiation may be considerably reduced by decreasing the number of clinically unwarranted X-ray examination of storage and delivery of diagnostic information and adopting a system for physical and technical quality control of the X-ray equipment. The aim of this investigation is assessment of the collective effective doses for the patients with occupational diseases exposed to ionizing radiation by radiological diagnostics. The study covers the period of 1990 through 1999. A total of 3293 patients, treated in the Department of Occupational Toxicology, Clinic of Occupational Diseases, Medical University - Sofia, were examined with X-ray and KT (cervical and lumbar spine, chest, skull, stomach, extremities, pelvis, brain). Most of the observed patients were with predominantlyheavy metals poisonings and a few with other chemical agents poisonings. Number of patients with radiological examinations was 1938, number of examination per capita was 0,59 and the total number of radiological examinations was 2536. The average number of radiological examination for one patient was 1,36, the most number of radiological examinations for one patient was 4. The collective effective dose for an examined patient was 1803 man.mSv. Our results shown the essential of the raising ensure that the medical exposure of patients be the minimum necessary to achieve the required diagnostic objective. (author)

  11. Achievement report for fiscal 1999 on the development of total evaluation research laboratory system for the medical welfare equipment technology research and development project; 1999 nendo iryo fukushi kiki gijutsu kenkyu kaihatsu project yo sogo hyoka kenkyu rabo system kaihatsu jigyo seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-05-01

    A laboratory system named above has been developed to propel forward efficiently the efforts to develop medical welfare technologies through close coordination between medicine and engineering. Six laboratories are linked with each other in a network for the realization of an environment in which general support is extended to all the stages of equipment development from basic through clinical assessment. The biomedical engineering laboratory is constituted of various analyzing devices, and is capable of in vitro assessment of bioingredients. The therapeutic laboratory is provided with bioinformation/NMR (nuclear magnetic resonance) measurement equipment, animal surgical operation equipment, etc., and performs the assessment of test animals at the first stage of clinical assessment. The diagnostic laboratory acquires various image data necessary for the development of medical equipment at the same level as that of the site of clinical diagnosis. The intelligent surgical operation room takes in real-time diagnostic images while a surgical operation is under way and, at the same time, assesses surgical devices in the same environment as that of the surgical operation room. The medical information laboratory accumulates medical and image data from the other laboratories, and integrates the accumulated data. The data management center manages the laboratories in a unified way and enables comprehensive assessment and research. (NEDO)

  12. Upgradation of nuclear medical equipment in the developing countries and its impact in Bangladesh

    CERN Document Server

    Jahangir, S M; Haque, M A S; Hoq, M; Mawla, Y; Morium, T; Uddin, M R; Xie, Y

    2002-01-01

    Bangladesh has thirteen Nuclear Medical Centres and one Institute of Nuclear Medicine in the country which are being run and maintained by the physicians scientists and engineers of Bangladesh Atomic Energy Commission. The peaceful application of atomic energy was initiated through all these Centres with the use of clinical isotopes for thyroid and kidney studies. The equipment used for these purposes were the thyroid uptake system, rectilinear scanner and the multiprobe renogram system. The first gamma camera was installed in the country in 1980 at the Institute of Nuclear Medicine, Dhaka. That was the turning point for the country in the field of nuclear medicine. Presently all the nuclear medical establishments are equipped least with a gamma camera, thyroid uptake system and a renogram system. In the last two decades there has been a tremendous development in the design of nuclear medical equipment. Most of the old equipments were slow and manually operated. In the beginning of nineties of the past centur...

  13. Development of Skylab medical equipment and flight preparations

    Science.gov (United States)

    Johnston, R. S.; Stonesifer, J. C.; Hawkins, W. R.

    1975-01-01

    The major medical systems in the Skylab orbital workshop are described. They comprise the food system, the waste management system, operational bioinstrumentation, personal hygiene, gas sampling, an inflight medical support system, and a cardiovascular counterpressure garment. Life sciences experiments carried out aboard Skylab are also reviewed; these include an ergometer and metabolic analyzer, a lower-body negative pressure device, an electrode harness and body temperature probe, a blood pressure cuff, a leg volume measuring band, sleep studies, a body-mass measuring device, a rotating litter chair, a blood sample processor, and small-mass measuring apparatus. All performance requirements were met with the equipment, and no failures were encountered.

  14. X-ray application in diagnostics and therapeutics

    International Nuclear Information System (INIS)

    Braun, H.

    1975-01-01

    The lecture gives a general survey on the present possibilities of application of X-rays and radio-isotopes in medical diagnostics and therapeutics. The possibility of decreasing the radiation exposure by using image intensifiers and television is particularly indicated. The advantages of scintiscanning in diagnostics are presented by means of a series of examples. The increasing significance of telecurie equipment and particle accelerators are refered to in therapeutics. Finally, the radiation risk due to the medical application of radiation to the patient and the personnel is discussed and compared to the natural radiation exposure. (ORU/LH) [de

  15. Medical diagnostic laboratories provisioning of services in India

    Directory of Open Access Journals (Sweden)

    Rahi Jain

    2015-01-01

    Full Text Available Context: Diagnostic services have a very important role to play in medical decision-making, which have an impact on the nation′s health status. The understanding of Indian diagnostic services provisioning has certain literature gaps. Aims: This study focused on understanding the functioning of provision of diagnostic services by Indian diagnostic laboratories. Materials and Methods: Exploratory field visits and literature review were used as tools to understand the Indian health system. Results: Indian diagnostic laboratory can be classified into various categories based on the type of services provided and governance. The difference in their financing, resources, quality assurance of services and patient access to services was found in these different laboratories. Conclusions: It was concluded from the study that patient′s access to laboratory services is affected by the functioning of laboratories in terms of governance, financing, resources, quality assurance of services and patient services.

  16. Evidence-based approach to the maintenance of laboratory and medical equipment in resource-poor settings.

    Science.gov (United States)

    Malkin, Robert; Keane, Allison

    2010-07-01

    Much of the laboratory and medical equipment in resource-poor settings is out-of-service. The most commonly cited reasons are (1) a lack of spare parts and (2) a lack of highly trained technicians. However, there is little data to support these hypotheses, or to generate evidence-based solutions to the problem. We studied 2,849 equipment-repair requests (of which 2,529 were out-of-service medical equipment) from 60 resource-poor hospitals located in 11 nations in Africa, Europe, Asia, and Central America. Each piece of equipment was analyzed by an engineer or an engineering student and a repair was attempted using only locally available materials. If the piece was placed back into service, we assumed that the engineer's problem analysis was correct. A total of 1,821 pieces of medical equipment were placed back into service, or 72%, without requiring the use of imported spare parts. Of those pieces repaired, 1,704 were sufficiently documented to determine what knowledge was required to place the equipment back into service. We found that six domains of knowledge were required to accomplish 99% of the repairs: electrical (18%), mechanical (18%), power supply (14%), plumbing (19%), motors (5%), and installation or user training (25%). A further analysis of the domains shows that 66% of the out-of-service equipment was placed back into service using only 107 skills covering basic knowledge in each domain; far less knowledge than that required of a biomedical engineer or biomedical engineering technician. We conclude that a great majority of laboratory and medical equipment can be put back into service without importing spare parts and using only basic knowledge. Capacity building in resource-poor settings should first focus on a limited set of knowledge; a body of knowledge that we call the biomedical technician's assistant (BTA). This data set suggests that a supported BTA could place 66% of the out-of-service laboratory and medical equipment in their hospital back

  17. Upgradation of nuclear medical equipment in the developing countries and its impact in Bangladesh

    International Nuclear Information System (INIS)

    Jahangir, Saleh Mahmud; Xie, Y.; Uddin, Md. Rokon; Haque, Mohammod Abu Sayid; Hoq, Mahbubul; Mawla, Yasmeen; Alom, Md. Zahangir; Morium, Tasnim

    2002-11-01

    Bangladesh has thirteen Nuclear Medical Centres and one Institute of Nuclear Medicine in the country which are being run and maintained by the physicians scientists and engineers of Bangladesh Atomic Energy Commission. The peaceful application of atomic energy was initiated through all these Centres with the use of clinical isotopes for thyroid and kidney studies. The equipment used for these purposes were the thyroid uptake system, rectilinear scanner and the multiprobe renogram system. The first gamma camera was installed in the country in 1980 at the Institute of Nuclear Medicine, Dhaka. That was the turning point for the country in the field of nuclear medicine. Presently all the nuclear medical establishments are equipped least with a gamma camera, thyroid uptake system and a renogram system. In the last two decades there has been a tremendous development in the design of nuclear medical equipment. Most of the old equipments were slow and manually operated. In the beginning of nineties of the past century there was an uprising in the computer technology and most of the manually operated machines were brought under computerization. It was basically done with a custom built processor to perform only the specific job and spare the users from doing some extra manual work. But the performances of the recent models of the same computerized equipment are by far the best as compared with the past ones. This report describes the role of the IAEA in the upgradation of medical equipment, PC interfacing, upgrading of old gamma cameras and the technological and socio-economic impact in Bangladesh

  18. 38 CFR 17.351 - Grants for the replacement and upgrading of equipment at Veterans Memorial Medical Center.

    Science.gov (United States)

    2010-07-01

    ... replacement and upgrading of equipment at Veterans Memorial Medical Center. 17.351 Section 17.351 Pensions... Philippines § 17.351 Grants for the replacement and upgrading of equipment at Veterans Memorial Medical Center. Grants to assist the Republic of the Philippines in the replacement and upgrading of equipment and in...

  19. Evaluation of E.M.F. exposure from medical electrical equipment

    Energy Technology Data Exchange (ETDEWEB)

    Aniolczyk, H.; Mamrot, P.; Politanski, P. [Nofer Institute of Occupational Medicine, Lodz (Poland)

    2006-07-01

    he medical electric and electronic equipment, including electro surgical devices, short- and microwave diathermy units, and magnetic resonance imaging (MRI) systems, belong to the most hazardous sources of electromagnetic emissions. The electromagnetic emissions can interfere with emissions from other medical equipment located in the same facility (e.g. operation rooms) thus having impact on their work, but more importantly, they can be dangerous to patients, medical personnel operating them and other persons. In the present project, an assessment of E.M.F. intensity was performed for more than 2 000 electro surgical devices (330 khz, 440 khz and 1.76 MHz frequency ranges), 1 200 diathermy units and 45 MRI 0.2 - 1.5 T systems. E.M.F. exposure of medical staff was assessed based on respective national hygienic standards. The actual exposure levels were found to exceed the admissible values in Poland. The recorded E.M.F. intensities were compared with relevant Who and U E recommendations (e.g. I.C.N.I.R.P. guidelines, 1998, Directive 2004/40/E.C.). The findings revealed that for 18% of the devices examined, the E.M.F. was higher than the E.M.F. intensity values recommended by U E. (authors)

  20. Evaluation of E.M.F. exposure from medical electrical equipment

    International Nuclear Information System (INIS)

    Aniolczyk, H.; Mamrot, P.; Politanski, P.

    2006-01-01

    he medical electric and electronic equipment, including electro surgical devices, short- and microwave diathermy units, and magnetic resonance imaging (MRI) systems, belong to the most hazardous sources of electromagnetic emissions. The electromagnetic emissions can interfere with emissions from other medical equipment located in the same facility (e.g. operation rooms) thus having impact on their work, but more importantly, they can be dangerous to patients, medical personnel operating them and other persons. In the present project, an assessment of E.M.F. intensity was performed for more than 2 000 electro surgical devices (330 khz, 440 khz and 1.76 MHz frequency ranges), 1 200 diathermy units and 45 MRI 0.2 - 1.5 T systems. E.M.F. exposure of medical staff was assessed based on respective national hygienic standards. The actual exposure levels were found to exceed the admissible values in Poland. The recorded E.M.F. intensities were compared with relevant Who and U E recommendations (e.g. I.C.N.I.R.P. guidelines, 1998, Directive 2004/40/E.C.). The findings revealed that for 18% of the devices examined, the E.M.F. was higher than the E.M.F. intensity values recommended by U E. (authors)

  1. ER-1A-DEL-92 regulation. Procedure for evaluation and registration of medical equipment

    International Nuclear Information System (INIS)

    2015-01-01

    The objectives of this regulation is to provide additional guidance on the method of evaluation and registration of a medical team, so it is used by manufacturers, health institutions, testing centers and other institutions related to the topic. The provisions of this regulation apply to domestically produced medical equipment in relation to the necessary assessment for registration purposes of a medical team. However, the evaluation process may require evaluations and tests not explicitly included in this regulation, so that at each stage of the process the Center for State Control of Medical Equipment (Center) set the requirements for each computer or device class in particular.

  2. FY 2000 Report on the results of the survey/research on advanced medical treatment equipment technology of the next generation; 2000 nendo jisedai senshin iryo kiki gijutsu ni kakawaru chosa kenkyu hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    For development of the advanced medical treatment equipment technology of the next generation, attempts are made to translate the policy targets, established through open discussions at the workshops and others, into the concrete techniques. As a result, the basic plans are concretely drafted for the (development of the gene-aided diagnostic system equipment for clinical purposes) and (development of heart disease treatment system equipment). The program for the (development of the gene-aided diagnostic system equipment for clinical purposes) is aimed at development of the system equipment which utilizes DNA microarrays and others to analyze the gene information highly reliably, quickly at low cost by simple procedure. The program for the (development of heart disease treatment system equipment) is aimed at development of various techniques, e.g., low-invasion type supercompact composite sensors capable of continuously measuring two or more types of information from a living body, basic techniques therefor, living hybridization techniques for stably operating these devices in a living body for extended periods, and intelligent drug delivery systems carrying multi-channel information transmission mechanisms and two or more types of drugs, and capable of delivering drugs independently at high precision. (NEDO)

  3. Medical Ethics and Protection from Excessive Radiation

    International Nuclear Information System (INIS)

    Ruzicka, I.

    1998-01-01

    Among artificial sources of ionic radiation people are most often exposed to those emanating from X-ray diagnostic equipment. However, responsible usage of X-ray diagnostic methods may considerably reduce the general exposure to radiation. A research on rational access to X-ray diagnostic methods conducted at the X-ray Cabinet of the Tresnjevka Health Center was followed by a control survey eight years later of the rational methods applied, which showed that the number of unnecessary diagnostic examining was reduced for 34 % and the diagnostic indications were 10-40 $ more precise. The results therefore proved that radiation problems were reduced accordingly. The measures applied consisted of additional training organized for health care workers and a better education of the population. The basic element was then the awareness of both health care workers and the patients that excessive radiation should be avoided. The condition for achieving this lies in the moral responsibility of protecting the patients' health. A radiologist, being the person that promotes and carries out this moral responsibility, should organize and hold continual additional training of medical doctors, as well as education for the patients, and apply modern equipment. The basis of such an approach should be established by implementing medical ethics at all medical schools and faculties, together with the promotion of a wider intellectual and moral integrity of each medical doctor. (author)

  4. Email for communicating results of diagnostic medical investigations to patients.

    Science.gov (United States)

    Meyer, Barbara; Atherton, Helen; Sawmynaden, Prescilla; Car, Josip

    2012-08-15

    As medical care becomes more complex and the ability to test for conditions grows, pressure on healthcare providers to convey increasing volumes of test results to patients is driving investigation of alternative technological solutions for their delivery. This review addresses the use of email for communicating results of diagnostic medical investigations to patients. To assess the effects of using email for communicating results of diagnostic medical investigations to patients, compared to SMS/ text messaging, telephone communication or usual care, on outcomes, including harms, for health professionals, patients and caregivers, and health services. We searched: the Cochrane Consumers and Communication Review Group Specialised Register, Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library, Issue 1 2010), MEDLINE (OvidSP) (1950 to January 2010), EMBASE (OvidSP) (1980 to January 2010), PsycINFO (OvidSP) (1967 to January 2010), CINAHL (EbscoHOST) (1982 to February 2010), and ERIC (CSA) (1965 to January 2010). We searched grey literature: theses/dissertation repositories, trials registers and Google Scholar (searched July 2010). We used additional search methods: examining reference lists and contacting authors. Randomised controlled trials, quasi-randomised trials, controlled before and after studies and interrupted time series studies of interventions using email for communicating results of any diagnostic medical investigations to patients, and taking the form of 1) unsecured email 2) secure email or 3) web messaging. All healthcare professionals, patients and caregivers in all settings were considered. Two review authors independently assessed the titles and abstracts of retrieved citations. No studies were identified for inclusion. Consequently, no data collection or analysis was possible. No studies met the inclusion criteria, therefore there are no results to report on the use of email for communicating results of diagnostic medical

  5. An approach to human-centered design of nuclear medical equipment: the system of caption of the thyroid

    International Nuclear Information System (INIS)

    Santos, Isaac J.A. Luquetti; Silva, Carlos Borges da; Santana, Marcos; Carvalho, Paulo Victor R.; Oliveira, Mauro Vitor de; Mol, Antonio Carlos Mol; Grecco, Claudio Henrique; Augusto, Silas Cordeiro

    2005-01-01

    Technology plays an important role in modern medical centers, making health care increasingly complex, relying on complex technical equipment. This technical complexity is particularly noticeable in the nuclear medicine and can increase the risks for human error. Human error has many causes such as performance shaping factors, organizational factors and user interface design. Poorly design human system interfaces of nuclear medical equipment can increase the risks for human error. If all nuclear medical equipment had been designed with good user interfaces, incidents and accidents could be reduced as well as he time required to learn how to use the equipment. Although some manufacturers of nuclear medical equipment have already integrate human factors principles in their products, there is still a need to steer the development of nuclear medical technology toward more human-centered approach. The aim of this paper is to propose a methodology that contributes to the design, development and evaluation of nuclear medical equipment and human system interface, towards a human-centered approach. This methodology includes the ergonomic approach, based on the operator activity analysis, together with human factors standards and guidelines, questionnaires and user based testing. We describe a case study in which this methodology is being applied in evaluation of the thyroid uptake system, getting essential information and data, that ill be used in development of a new system. (author)

  6. System theory in medical diagnostic devices: an overview.

    Science.gov (United States)

    Baura, Gail D

    2006-01-01

    Medical diagnostics refers to testing conducted either in vitro or in vivo to provide critical health care information for risk assessment, early diagnosis, treatment, or disease management. Typical in vivo diagnostic tests include the computed tomography scan, magnetic resonance imaging, and blood pressure screening. Typical in vitro diagnostic tests include cholesterol, Papanicolaou smear, and conventional glucose monitoring tests. Historically, devices associated with both types of diagnostics have used heuristic curve fitting during signal analysis. However, since the early 1990s, a few enterprising engineers and physicians have used system theory to improve their core processing for feature detection and system identification. Current applications include automated Pap smear screening for detection of cervical cancer and diagnosis of Alzheimer's disease. Future applications, such as disease prediction before symptom onset and drug treatment customization, have been catalyzed by the Human Genome Project.

  7. Methodology for quantitative evaluation of diagnostic medical imaging

    International Nuclear Information System (INIS)

    Metz, C.

    1980-01-01

    This report deals with the evaluation of the performance of diagnostic medical imaging procedures using the Receiver Operating Characteristic or ROC analysis. The development of new tests for the statistical significance of apparent differences between ROC curves is discussed

  8. Analysis of environmental impact assessment for large-scale X-ray medical equipments

    International Nuclear Information System (INIS)

    Fu Jin; Pei Chengkai

    2011-01-01

    Based on an Environmental Impact Assessment (EIA) project, this paper elaborates the basic analysis essentials of EIA for the sales project of large-scale X-ray medical equipment, and provides the analysis procedure of environmental impact and dose estimation method under normal and accident conditions. The key points of EIA for the sales project of large-scale X-ray medical equipment include the determination of pollution factor and management limit value according to the project's actual situation, the utilization of various methods of assessment and prediction such as analogy, actual measurement and calculation to analyze, monitor, calculate and predict the pollution during normal and accident condition. (authors)

  9. EM-18-2008 regulation. Essential requirements for the registration of medical equipment

    International Nuclear Information System (INIS)

    2015-01-01

    This rule lays down additional rules for the evaluation and the State Control of Medical Equipment provisions. Medical equipment must be designed and constructed so that they are used under the conditions and for the intended purpose and shall, where applicable, by virtue of the technical knowledge, experience, education or training of users, do not compromise the clinical condition or safety of patients, or the safety and health of users or, where applicable, other persons, assuming that any risks that may be associated with their use constitute acceptable risks versus the benefits for the patient and is compatible with a high level of protection of health and safety.

  10. A thermal technique for local ultrasound intensity measurement: part 2. Application to exposimetry on a medical diagnostic device

    International Nuclear Information System (INIS)

    Wilkens, V

    2010-01-01

    Acoustic output measurements on medical ultrasound equipment are usually performed using radiation force balances to determine the output power and using hydrophones to determine pressure and intensity parameters. The local temporal-average ultrasound intensity can be measured alternatively by thermal sensors. The technique was described and prototype sensors were characterized in a preceding paper. Here, the application of such a thermal intensity sensor to the output beam characterization of a typical medical diagnostic device is described. Two transducers, a 7.5 MHz linear array and a 3.5 MHz convex array were investigated in different operating modes. For comparison, hydrophone measurements were also performed. If the spatial averaging effect is taken into account, good agreement is found between both measurement methods. The maximum deviations of the spatial-peak temporal-average intensities I SPTA obtained with the thermal sensor from the corresponding hydrophone-based results were below 12%. The simple thermal technique offers advantages for intensity measurements especially in the case of scanning and combined modes of the diagnostic device, where the synchronization between hydrophone measurements and the complex pulse emission pattern can be difficult

  11. 15 CFR Notes Applicable to State... - Notes applicable to State of Understanding related to Medical Equipment:

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Notes applicable to State of Understanding related to Medical Equipment: applicable Notes applicable to State of Understanding related to Medical Equipment: Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY,...

  12. 3D web based learning of medical equipment employed in intensive care units.

    Science.gov (United States)

    Cetin, Aydın

    2012-02-01

    In this paper, both synchronous and asynchronous web based learning of 3D medical equipment models used in hospital intensive care unit have been described over the moodle course management system. 3D medical equipment models were designed with 3ds Max 2008, then converted to ASE format and added interactivity displayed with Viewpoint-Enliven. 3D models embedded in a web page in html format with dynamic interactivity-rotating, panning and zooming by dragging a mouse over images-and descriptive information is embedded to 3D model by using xml format. A pilot test course having 15 h was applied to technicians who is responsible for intensive care unit at Medical Devices Repairing and Maintenance Center (TABOM) of Turkish High Specialized Hospital.

  13. Private sector involvement in times of armed conflict: What are the constraints for trading medical equipment?

    Science.gov (United States)

    Schmidt, Georg

    Today, healthcare facilities are highly dependent on the private sector to keep their medical equipment functioning. Moreover, private sector involvement becomes particularly important for the supply of spare parts and consumables. However, in times of armed conflict, the capacity of the corporate world appears to be seriously hindered. Subsequently, this study researches the influence of armed conflict on the private medical equipment sector. This study follows a qualitative approach by conducting 19 interviews with representatives of the corporate world in an active conflict zone. A semistructured interview guide, consisting of 10 questions, was used to examine the constraints of this sector. The results reveal that the lack of skilled personnel, complicated importation procedures, and a decrease in financial capacity are the major constraints faced by private companies dealing in medical equipment in conflict zones. Even when no official sanctions and embargoes for medical items exist, constraints for trading medical equipment are clearly recognizable. Countries at war would benefit from a centralized structure that deals with the importation procedures for medical items, to assist local companies in their purchasing procedures. A high degree of adaption is needed to continue operating, despite the emerging constraints of armed conflict. Future studies might research the constraints for manufacturers outside the conflict to export medical items to the country of war.

  14. Differential diagnostic value of procalcitonin in surgical and medical patients with septic shock.

    Science.gov (United States)

    Clec'h, Christophe; Fosse, Jean-Philippe; Karoubi, Philippe; Vincent, Francois; Chouahi, Imad; Hamza, Lilia; Cupa, Michel; Cohen, Yves

    2006-01-01

    To assess whether different diagnostic and prognostic cutoff values of procalcitonin should be considered in surgical and in medical patients with septic shock. Prospective observational study. Intensive care unit of the Avicenne teaching hospital, France. All patients with septic shock or noninfectious systemic inflammatory response syndrome within 48 hrs after admission. None. Patients were allocated to one of the following groups: group 1 (surgical patients with septic shock), group 2 (surgical patients with noninfectious systemic inflammatory response syndrome), group 3 (medical patients with septic shock), and group 4 (medical patients with noninfectious systemic inflammatory response syndrome). Procalcitonin at study entry was compared between group 1 and group 2 and between group 3 and group 4 to determine the diagnostic cutoff value in surgical and in medical patients, respectively. Procalcitonin was compared between survivors and nonsurvivors from group 1 and group 3 to determine its prognostic cutoff value. One hundred forty-three patients were included: 31 in group 1, 36 in group 2, 36 in group 3, and 40 in group 4. Median procalcitonin levels (ng/mL [interquartile range]) were higher in group 1 than in group 3 (34.00 [7.10-76.00] vs. 8.40 [3.63-24.70], p = .01). In surgical patients, the best diagnostic cutoff value was 9.70 ng/mL, with 91.7% sensitivity and 74.2% specificity. In medical patients, the best diagnostic cutoff value was 1.00 ng/mL, with 80% sensitivity and 94% specificity. Procalcitonin was a reliable early prognostic marker in medical but not in surgical patients with septic shock. A cutoff value of 6.00 ng/mL had 76% sensitivity and 72.7% specificity for separating survivors from nonsurvivors. The diagnostic cutoff value of procalcitonin was higher in surgical than in medical patients. Early procalcitonin was of prognostic interest in medical patients.

  15. Analysis of errors during medical and computerized diagnostics of spherical lung neoplasms

    International Nuclear Information System (INIS)

    Pozmogov, A.I.; Petruk, D.A.

    1985-01-01

    Reasons for errors in medical and computerized diagnostics of spherical lung neoplasms are studied based on material of 212 case records and clinicoroentgenological data; it should promote improvement of their diagnostics

  16. A method for performance assessment of medical radioisotope equipment

    International Nuclear Information System (INIS)

    Kerin, T.; Slavtchev, Ath.; Nedeltchev, M.; Kjurktchiev, T.

    1984-01-01

    A variety of tests and procedures exist for the performance assessment of radioisotope diagnostic equipment. The complex performance index which has been introduced to date is based on an heuristic approach. The present work tries to interconnect algorithmically the most important factors as the influence of the measurement geometry, the statistic peculiarities for lower activities and the information loss at high count rates. All this is reflected in a criterion which integrates the spatial resolution, the effective detector's field of vision, the radionuclide's sensitivity, the background count rate and the effective dead-time of the system under investigation. (Auth.)

  17. TU-G-213-03: IEC Subcommittee 62C (Equipment for Radiotherapy, Nuclear Medicine and Radiation Dosimetry): Recent and Active Projects

    Energy Technology Data Exchange (ETDEWEB)

    Culberson, W. [University of Wisconsin - Madison (United States)

    2015-06-15

    The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists.

  18. ER-E4 regulation. Transitional arrangement to implement the rules for evaluating and state control of medical equipment

    International Nuclear Information System (INIS)

    2015-01-01

    Establish a regulatory document where the validity and status of the documents contained in the Regulatory Legal Base Technical Program of medical equipment is exposed, given the scope thereof to comply with the provisions of the Regulation. This regulation is aimed at all subjects (manufacturers or producers, suppliers or distributors, importers, users, medical equipment, as well as health institutions SNS) involved in activities related to the evaluation and control of the State Medical equipment and make use of complementary technical legal documents.

  19. Procurement of medical equipment in Sweden

    Directory of Open Access Journals (Sweden)

    Heikki Terio

    2010-02-01

    Full Text Available In many hospitals in Sweden the importance of technology management is already accepted and accepted since the hospital managements have recognised that technology is an integral part of all major policy and planning decisions. Today’s medical devices are technically complex and sometimes a system of interacting devices is required to achieve the desired clinical function. If the hospitals want to use the latest, modern technology, then they need to make substantial investments in both equipment and competence. Complex technology, large investments and need of highly qualii ed personnel to handle the medical devices are factors that indicate a need of well-dei ned procurement process as an essential part of the total health technology management system that should be used in a hospital. In such a procurement process, carefully prepared planning of technology investments can reduce the running costs and costs for maintenance substantially. In addition, a well-dei ned procurement process contributes to increase the patient safety. In Karolinska University Hospital goods and services are purchased for more than 20% of the hospital’s €1.2 billion turnover. It is therefore very important that the procurement is carried out ef ectively.

  20. Quality control in dental diagnostic radiology : anomalous in the use of radiological equipment

    International Nuclear Information System (INIS)

    Alcaraz, M.; Martinez-Beneyto, Y.; Jodar, S.; Velasco, E.; Garcia-Vera, M. C.

    2004-01-01

    7,176 official quality control reports on dental diagnostic radiology were studied, relating to dental clinics located in 37 Spanish provinces covering 16 different autonomous Regions. The reports were issued as a result of the entry into force of Royal Decree 2071/1995 on quality control in General Diagnostic Radiology facilities, this Royal Decree was replaced by R. D. 1976/1999. The reports were writen by the UTPR (Technical Unit of Radiological Protection) Agsigma S. A. L., a company approved by the Nuclear Safety Council, and they correspond with the official reports issued during 1996-2001. This meants that a 5-year period has been monitored in order to observe the impacts of the establlishment of this legislation on quality control in intraoral dental diagnostic radiology facilities. The results show that 72.79% of the reports checked in 2001 would comply with the European Union's official recommendation (70 kVp, 8 mA> 1.5 mm of Al and 20 cm collimator length). Significant alterations have detected in a third (30.59%) of the radiological equipment. (Author) 36 refs

  1. Equipment for measuring torque and diagnostic data on control rod drive of nuclear reactor

    International Nuclear Information System (INIS)

    Simka, K.; Sneberger, J.; Tater, V.

    1991-01-01

    The equipment comprises an electric drive, a measuring unit and a device securing the movable parts of the drive. It can be used to measure the torque and diagnostic data of the control facility drive with the desired accuracy without having to dismantle the facility during decoupling or coupling the control component to the drive, during programming the movable parts in the transporting position. (Z.S.). 1 fig

  2. Equipment for radiation diagnostics

    International Nuclear Information System (INIS)

    Tschunt, E.; Platz, W.

    1976-01-01

    The invention relates to an improvement of the line type of the plotter in an X-ray diagnostics apparatus enabling the production of distinguishable recordings by means of a single plot type. The construction is described explicitly. (UWI) [de

  3. Effectiveness of Medical-Care Equipment Management: Case Study in a Public Hospital in Belo Horizonte / Minas Gerais

    OpenAIRE

    Estevão Maria Campolina de Oliveira; Eloísa Helena Rodrigues Guimaraes; Ester Eliane Jeunon

    2017-01-01

    This study aimed to identify and analyze the factors that contribute to the effectiveness of the management of medical-care equipment at the Hospital of Federal University of Minas Gerais (HC-UFMG) in Belo Horizonte, Minas Gerais. To achieve this goal, a case study was performed along with a field research at HC-UFMG, through interviews using a semi-structured questionnaire to professionals who handle and operate medical-care equipment; professionals who provide maintenance on equipment, and ...

  4. Sherlock Holmes' methods of deductive reasoning applied to medical diagnostics.

    Science.gov (United States)

    Miller, L

    1985-03-01

    Having patterned the character of Sherlock Holmes after one of his professors, Sir Arthur Conan Doyle, himself a physician, incorporated many of the didactic qualities of the 19th century medical diagnostician into the character of Holmes. In this paper I explore Holmes's techniques of deductive reasoning and their basis in 19th and 20th century medical diagnostics.

  5. A Fuzzy method for the usability evaluation of nuclear medical equipment

    Energy Technology Data Exchange (ETDEWEB)

    Grecco, Cláudio H.S.; Santos, Isaac J.A.L.; Farias, Marcos S.; Farias, Larissa P.; Filho, Alfredo M.V., E-mail: grecco@ien.gov.br, E-mail: luquetti@ien.gov.br, E-mail: msantana@ien.gov.br, E-mail: larissapfarias@ymail.com, E-mail: marques@ien.gov.br [Instituto de Engenharia Nuclear (DENN/IEN/CNEN/RJ), Rio de Janeiro, RJ (Brazil). Departamento de Engenharia Nuclear

    2017-11-01

    To avoid errors when handling nuclear medical equipment, it is important to develop products with a high degree of usability. This can be achieved by performing usability evaluations in the product development process to detect and mitigate potential usability problems. Usability evaluation focuses on how well users can learn and use a product to achieve their goals. Thus, the usability evaluation has become recognized as a valuable complement to the established approaches to design good user interfaces, to reduce incidents and accidents as well the time required to learn how to use the equipment. To gather information about usability, practitioners use a variety of methods that gather feedback from users about an existing interface or plans related to a new interface. A wide range of usability evaluation methods have been proposed, but few methods focus on developing an objective and practical evaluation method for usability. Moreover, the usability evaluations are based on human judgments and most methods cannot fully solve the subjectivity of these evaluations. In order to remedy this deficiency, the purpose of this work is to adopt a Fuzzy Set Theory (FST) approach to establish a method for the usability evaluation of nuclear medical equipment based on usability heuristics for user interface design and international standards for ergonomics of human-system interaction. To exemplify the method we performed a usability evaluating of the Digital Spectrometer ESP 13004 by testing it with representative users. The results showed that the method is a proactive tool to provide a basis for checking usability of medical device interfaces. (author)

  6. A Fuzzy method for the usability evaluation of nuclear medical equipment

    International Nuclear Information System (INIS)

    Grecco, Cláudio H.S.; Santos, Isaac J.A.L.; Farias, Marcos S.; Farias, Larissa P.; Filho, Alfredo M.V.

    2017-01-01

    To avoid errors when handling nuclear medical equipment, it is important to develop products with a high degree of usability. This can be achieved by performing usability evaluations in the product development process to detect and mitigate potential usability problems. Usability evaluation focuses on how well users can learn and use a product to achieve their goals. Thus, the usability evaluation has become recognized as a valuable complement to the established approaches to design good user interfaces, to reduce incidents and accidents as well the time required to learn how to use the equipment. To gather information about usability, practitioners use a variety of methods that gather feedback from users about an existing interface or plans related to a new interface. A wide range of usability evaluation methods have been proposed, but few methods focus on developing an objective and practical evaluation method for usability. Moreover, the usability evaluations are based on human judgments and most methods cannot fully solve the subjectivity of these evaluations. In order to remedy this deficiency, the purpose of this work is to adopt a Fuzzy Set Theory (FST) approach to establish a method for the usability evaluation of nuclear medical equipment based on usability heuristics for user interface design and international standards for ergonomics of human-system interaction. To exemplify the method we performed a usability evaluating of the Digital Spectrometer ESP 13004 by testing it with representative users. The results showed that the method is a proactive tool to provide a basis for checking usability of medical device interfaces. (author)

  7. 21 CFR 862.2050 - General purpose laboratory equipment labeled or promoted for a specific medical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false General purpose laboratory equipment labeled or... TOXICOLOGY DEVICES Clinical Laboratory Instruments § 862.2050 General purpose laboratory equipment labeled or promoted for a specific medical use. (a) Identification. General purpose laboratory equipment labeled or...

  8. Procuring, maintaining and using equipment: the key issues in controlling exposure to patients

    International Nuclear Information System (INIS)

    Hendra, I.R.F.

    1989-01-01

    Not only are acceptance criteria directly related to the design of medical x-ray equipment and quality assurance exercised during its manufacture, but also its performance, safety and reliability must feature in requirements for procuring new equipment. In the UK this issue is dealt with under the Department of Health and Social Security Manufacturer Registration Scheme for Medical Equipment in its application to radiological equipment. In the UK quality of maintenance services has been considered by one of our Working Parties commissioned by the South-East Thames Regional Health Authority who are the ''Centre of Responsibility'' for diagnostic imaging equipment in the National Health Service. The report prepared from the first phase of activity of this working group describes features of a procurement specification for maintenance services and prescribes complementary duties of contractors and customers. Radiograph reject analysis has indicated human error outweighs unsatisfactory equipment performance as the reason for rejecting poor radiographs. The use in X-ray departments of the kind of manufacturing quality system used by most reputable equipment manufacturers has the potential for a dramatic reduction in exposure. (author)

  9. Unintentional exposure to radiation during pregnancy from nuclear medical diagnostic procedures

    International Nuclear Information System (INIS)

    Moka, D.

    2005-01-01

    The administration of radiopharmaceuticals during pregnancy is contraindicated due to a lack of vital indications. However, if prenatal exposure to radiation should occur in the framework of a nuclear medical diagnostic procedure then fortunately no longterm side-effects would normally be expected. Radiation damage in the preimplantation phase leads to early abortion. However, if the further course of pregnancy remains uncomplicated then no subsequent side-effects need be expected. On a conservative estimate, it would require doses exceeding 50 mGy to cause radiation damage within the uterus after the preimplantation phase. However, the standard radioactivities applied for diagnostic purposes in nuclear medicine, can be obtained with doses of less than 20 mGy. On the basis of current knowledge, therefore, there is no reason to terminate pregnancy on medical grounds after diagnostic exposure to radiopharmaceuticals. (orig.)

  10. Regulation EM-ER-6. Requirements for the realization of clinical essays to the medical equipments

    International Nuclear Information System (INIS)

    2015-01-01

    This regulation applies to the medical equipment that become incorporated to the stage of clinical trial required for its evaluation and record, for which they are subdued to clinical investigation for the sake of verifying, in conditions specified of use, its functioning, identifying besides any undesirable defect. It extends to manufacturers of medical equipments, Public Health's units where the clinical investigations with those equipments take place and to the rest of the entities of the MINSAP . Its objective is to protect the participating subjects in the clinical investigations; Assuring the conduction of the clinical investigation and specifying the requirements for the conduction of the clinical investigations and the documentation required for it.

  11. Effectiveness of Medical-Care Equipment Management: Case Study in a Public Hospital in Belo Horizonte / Minas Gerais

    Directory of Open Access Journals (Sweden)

    Estevão Maria Campolina de Oliveira

    2017-03-01

    Full Text Available This study aimed to identify and analyze the factors that contribute to the effectiveness of the management of medical-care equipment at the Hospital of Federal University of Minas Gerais (HC-UFMG in Belo Horizonte, Minas Gerais. To achieve this goal, a case study was performed along with a field research at HC-UFMG, through interviews using a semi-structured questionnaire to professionals who handle and operate medical-care equipment; professionals who provide maintenance on equipment, and professionals who manage the operation and maintenance of equipment. As a strategy for discussion of the results, the Collective Subject Discourse (CSD was used supported by the analysis of the Central Idea (CI of each question or question groups. According to the CSD results, it was possible to identify factors that contribute to the effectiveness of the management of medical-care equipment, such as: professional qualification; practical knowledge; work professionalization; supervision focused on evaluation, development, results and continuous improvement; professional updating and technical support; individual accountability; adequate infrastructure; and implementation of equipment management planning. These factors indicate, to the institutions, opportunities of culture change and organizational growth.

  12. Interference by new-generation mobile phones on critical care medical equipment

    NARCIS (Netherlands)

    van Lieshout, Erik Jan; van der Veer, Sabine N.; Hensbroek, Reinout; Korevaar, Johanna C.; Vroom, Margreeth B.; Schultz, Marcus J.

    2007-01-01

    INTRODUCTION: The aim of the study was to assess and classify incidents of electromagnetic interference (EMI) by second-generation and third-generation mobile phones on critical care medical equipment. METHODS: EMI was assessed with two General Packet Radio Service (GPRS) signals (900 MHz, 2 W, two

  13. Sherlock Holmes's Methods of Deductive Reasoning Applied to Medical Diagnostics

    Science.gov (United States)

    Miller, Larry

    1985-01-01

    Having patterned the character of Sherlock Holmes after one of his professors, Sir Arthur Conan Doyle, himself a physician, incorporated many of the didactic qualities of the 19th century medical diagnostician into the character of Holmes. In this paper I explore Holmes's techniques of deductive reasoning and their basis in 19th and 20th century medical diagnostics. PMID:3887762

  14. Renewal of radiological equipment.

    Science.gov (United States)

    2014-10-01

    In this century, medical imaging is at the heart of medical practice. Besides providing fast and accurate diagnosis, advances in radiology equipment offer new and previously non-existing options for treatment guidance with quite low morbidity, resulting in the improvement of health outcomes and quality of life for the patients. Although rapid technological development created new medical imaging modalities and methods, the same progress speed resulted in accelerated technical and functional obsolescence of the same medical imaging equipment, consequently creating a need for renewal. Older equipment has a high risk of failures and breakdowns, which might cause delays in diagnosis and treatment of the patient, and safety problems both for the patient and the medical staff. The European Society of Radiology is promoting the use of up-to-date equipment, especially in the context of the EuroSafe Imaging Campaign, as the use of up-to-date equipment will improve quality and safety in medical imaging. Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or renewal. This plan should look forward a minimum of 5 years, with annual updates. Teaching points • Radiological equipment has a definite life cycle span, resulting in unavoidable breakdown and decrease or loss of image quality which renders equipment useless after a certain time period.• Equipment older than 10 years is no longer state-of-the art equipment and replacement is essential. Operating costs of older equipment will be high when compared with new equipment, and sometimes maintenance will be impossible if no spare parts are available.• Older equipment has a high risk of failure and breakdown, causing delays in diagnosis and treatment of the patient and safety problems both for the patient and the medical staff.• Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or replacement. This plan should look forward a

  15. [Investigation of non-ionizing radiation hazards from physiotherapy equipment in 16 medical institutions].

    Science.gov (United States)

    He, Jia-xi; Zhou, Wei; Qiu, Hai-li; Yang, Guang-tao

    2013-12-01

    To investigate the non-ionizing radiation hazards from physiotherapy equipment in medical institutions and to explore feasible control measures for occupational diseases. On-site measurement and assessment of ultra-high-frequency radiation, high-frequency electromagnetic field, microwave radiation, and laser radiation were carried out in 16 medical institutions using the methods in the Measurement of Physical Agents in Workplace (GBZ/T189-2007). All the investigated medical institutions failed to take effective protective measures against non-ionizing radiation. Of the 17 ultra-short wave therapy apparatus, 70.6%, 47.1%, and 17.64% had a safe intensity of ultra-high-frequency radiation on the head, chest, and abdomen, respectively. Of the 4 external high-frequency thermotherapy apparatus, 100%, 75%, and 75%had a safe intensity of high-frequency electromagnetic field on the head, chest, and abdomen, respectively. In addition, the intensities of microwave radiation and laser radiation produced by the 18 microwave therapy apparatus and 12 laser therapeutic apparatus met national health standards. There are non-ionizing radiation hazards from physiotherapy equipment in medical institutions, and effective prevention and control measures are necessary.

  16. Principles for new optical techniques in medical diagnostics for mHealth applications

    Science.gov (United States)

    Balsam, Joshua Michael

    Medical diagnostics is a critical element of effective medical treatment. However, many modern and emerging diagnostic technologies are not affordable or compatible with the needs and conditions found in low-income and middle-income countries and regions. Resource-poor areas require low-cost, robust, easy-to-use, and portable diagnostics devices compatible with telemedicine (i.e. mHealth) that can be adapted to meet diverse medical needs. Many suitable devices will need to be based on optical technologies, which are used for many types of biological analyses. This dissertation describes the fabrication and detection principles for several low-cost optical technologies for mHealth applications including: (1) a webcam based multi-wavelength fluorescence plate reader, (2) a lens-free optical detector used for the detection of Botulinum A neurotoxin activity, (3) a low cost micro-array reader that allows the performance of typical fluorescence based assays demonstrated for the detection of the toxin staphylococcal enterotoxin (SEB), and (4) a wide-field flow cytometer for high throughput detection of fluorescently labeled rare cells. This dissertation discusses how these technologies can be harnessed using readily available consumer electronics components such as webcams, cell phones, CCD cameras, LEDs, and laser diodes. There are challenges in developing devices with sufficient sensitivity and specificity, and approaches are presented to overcoming these challenges to create optical detectors that can serve as low cost medical diagnostics in resource-poor settings for mHealth.

  17. Medical image computing for computer-supported diagnostics and therapy. Advances and perspectives.

    Science.gov (United States)

    Handels, H; Ehrhardt, J

    2009-01-01

    Medical image computing has become one of the most challenging fields in medical informatics. In image-based diagnostics of the future software assistance will become more and more important, and image analysis systems integrating advanced image computing methods are needed to extract quantitative image parameters to characterize the state and changes of image structures of interest (e.g. tumors, organs, vessels, bones etc.) in a reproducible and objective way. Furthermore, in the field of software-assisted and navigated surgery medical image computing methods play a key role and have opened up new perspectives for patient treatment. However, further developments are needed to increase the grade of automation, accuracy, reproducibility and robustness. Moreover, the systems developed have to be integrated into the clinical workflow. For the development of advanced image computing systems methods of different scientific fields have to be adapted and used in combination. The principal methodologies in medical image computing are the following: image segmentation, image registration, image analysis for quantification and computer assisted image interpretation, modeling and simulation as well as visualization and virtual reality. Especially, model-based image computing techniques open up new perspectives for prediction of organ changes and risk analysis of patients and will gain importance in diagnostic and therapy of the future. From a methodical point of view the authors identify the following future trends and perspectives in medical image computing: development of optimized application-specific systems and integration into the clinical workflow, enhanced computational models for image analysis and virtual reality training systems, integration of different image computing methods, further integration of multimodal image data and biosignals and advanced methods for 4D medical image computing. The development of image analysis systems for diagnostic support or

  18. Assessment of Microbial Contamination of Surfaces and Medical Equipment in Wards of the Panjom Azar Hospital of Gorgan in 2014

    Directory of Open Access Journals (Sweden)

    Roghaye Noroozi

    2014-06-01

    Full Text Available Methods: In this cross-sectional study, different wards of panjom Azar educational hospital including ICU, dialysis and surgery room were investigated. Samples were collected randomly, for three months from July to September 2014, from beds, oxygen masks, oxygen manometer, patient table, covers of the patient's medical records, nurse's desk, border walls and water tap.  Samples were then cultured on blood agar and EMB agar. In order to determine the bacteria type, specific culture media with specific biochemical tests and diagnostic disks were used. Results: Results showed that from 216 samples collected from the levels, the 190 cases (88% had microbial contamination. Most of the recognized bacteria were Staphylococcus saprophyticus, Staphylococcus epidermidis, Staphylococcus aureus, Bacillus subtilis, Pseudomonas aeruginosa, Escherichia coli, Enterobacter and klebsiela. Results of microbial culture of equipments and levels were positive in case of bacterial contamination and maximum contamination was observed in the dialysis ward of the hospital. Conclusion: Due to the relatively high detected contamination, contamination control of levels and patient care equipments could considered as an effective action in reducing nosocomial infections. Thus, using appropriate disinfectant equipment, monitoring the disinfectants preparation, continuous monitoring and detection of common microorganisms are the most important ways for infection control in hospitals.

  19. National variation of ADHD diagnostic prevalence and medication use: health care providers and education policies.

    Science.gov (United States)

    Fulton, Brent D; Scheffler, Richard M; Hinshaw, Stephen P; Levine, Peter; Stone, Susan; Brown, Timothy T; Modrek, Sepideh

    2009-08-01

    Attention-deficit hyperactivity disorder (ADHD) diagnostic prevalence and medication use vary across U.S. census regions, but little is known about state-level variation. The purpose of this study was to estimate this variation across states and examine whether a state's health care provider characteristics and education policies are associated with this variation. Logistic regression models were estimated with 69,505 children aged four to 17 from the state-stratified and nationally representative 2003 National Survey of Children's Health, conducted by the Centers for Disease Control and Prevention. Diagnostic prevalence was higher in the South (odds ratio [OR]=1.42, p<.001) than in the West; among children with ADHD diagnoses, medication use was higher in the South (OR=1.60, p<.01) and the Midwest (OR=1.53, p<.01) versus the West. On these measures, several states differed from the U.S. averages, including some states that, on the basis of the regional patterns found above, would not be expected to differ: Michigan had a high diagnostic prevalence; Vermont, South Dakota, and Nebraska had low diagnostic prevalences; and Connecticut, New Jersey, and Kentucky had low medication rates. Both diagnosis and medication status were associated with the number, age, and type of physicians within a state, particularly pediatricians. However, state education policies were not significantly associated with either diagnostic prevalence or medication rates. To better understand the association between a state's health care provider characteristics and both diagnostic prevalence and medication use, it may be fruitful to examine the content of provider continuing education programs, including the recommendations of major health professional organization guidelines to treat ADHD.

  20. Reducing chronic obstructive pulmonary disease readmissions: the role of the durable medical equipment provider.

    Science.gov (United States)

    Messenger, Robert W

    2012-01-01

    Exacerbation and frequent rehospitalization in chronic obstructive pulmonary disease exacts a heavy toll on the US health care system. To address these issues, new initiatives have been proposed that are largely based on financial penalties to promote patient education and postdischarge care. However, as laudable as these goals are, improving outcomes in the chronic obstructive pulmonary disease population is more confounding than it may first appear. Chronic hypoxia, cognitive dysfunction, poor nutrition, and economic disadvantage are just a few of the challenges that require creative solutions and ongoing support. Case managers need to utilize all the potential products and services that can assist in improving outcomes for these patients. Durable medical equipment providers are often viewed as purveyors of medical equipment that offer little in the form of clinical support. However, in many cases these providers represent an overlooked resource that provides individualized, highly structured patient education and ongoing support programs. The challenge is in identifying those durable medical equipment providers that offer patients contemporary technology, and have both the resources and the commitment to provide patient support that is amenable to the goals of the hospital. This article reviews many of the confounding issues that contribute to the frequent rehospitalization of chronic obstructive pulmonary disease patients. Recommendations to improve patient education and oxygen therapy outcomes are provided along with suggestions to aid in the vetting of durable medical equipment providers. Acute care hospitals, long-term acute care hospitals, extended care facilities, integrated delivery systems. 1. An understanding of the complex variables that play in the management of chronic obstructive pulmonary disease will help the case manager to plan an effective course of care. 2. Case managers need to ensure that patients receive long-term oxygen technology that

  1. Possible radiation dose reduction by using digital X-ray equipment

    International Nuclear Information System (INIS)

    Horvathova, M.; Nikodemova, D.; Prikazska, M.

    2001-01-01

    The radiation load of population all over the world from medical examinations clearly demonstrates the importance of the introduction of the quality assurance and quality control programmes into the activities of radiology departments. The basic aim of quality assurance program is to ensure that the radiation dose is kept as low as reasonably practicable while still providing an adequate image quality. As many other fields, the rapid development of techniques brought change-over from the conventional analogue technique to the digital technique. In this process, the conventional X-ray film is being abandoned and images are being viewed on either laser film or monitor. The main advantages of using digital equipment lay in improved image quality and diagnostic accuracy through digital image processing, reduction in patients exposure, cost reduction by reduction of the film usage, more efficient storage and retrieval of radiographic images through picture archiving. Several studies that have been conducted for comparison of various diagnostic examinations show , that there is potential for dose saving in the digital image intensifier technique. The aim of this study was to compare measured values of dose-area product for colon investigations using different X-ray equipment types, two digital and two analogue. Our material consisted of 169 randomly selected patients, 115 of them were examined with digital equipment and 54 patients with the analogue equipment. The obtained results have confirmed the dose reduction and increase of diagnostic accuracy when using the digital equipment, with the added benefit of a good image quality. (authors)

  2. Dose evaluation in medical staff during diagnostics procedures in interventional radiology; Avaliacao da dose na equipe medica durante procedimentos diagnoticos de radiologia intervencionista

    Energy Technology Data Exchange (ETDEWEB)

    Bacchim Neto, Fernando A.; Alves, Allan F.F.; Rosa, Maria E.D.; Miranda, Jose R.A. [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Instituto de Biociencias. Departamento de Fisica e Biofisica; Moura, Regina [Faculdade de Medicina de Botucatu, SP (Brazil). Departamento de Cirurgia e Ortopedia; Pina, Diana R., E-mail: bacchim@ibb.unesp.br [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Faculdade de Medicina. Departamento de Doencas Tropicais e Diagnostico por Imagem

    2014-08-15

    Studies show that personal dosimeters may underestimate the dose values in interventional physicians, especially in extremities and crystalline. The objective of this work was to study the radiation exposure levels of medical staff in diagnostic interventional radiology procedures. For this purpose LiF:Mg,Ti (TLD-100) dosimeters were placed in different regions of the physician body. When comparing with reference dose levels, the maximum numbers of annual procedures were found. This information is essential to ensure the radiological protection of those professionals. (author)

  3. Quality control test solutions for diagnostic radiology, nuclear medicine and health physics with PTW equipment

    International Nuclear Information System (INIS)

    Froescher, Olga

    2007-01-01

    Complete test of publication follows. In 1922 PTW-Freiburg was founded to produce and market a revolutionary new electromechanical component for measuring very small electrical charges. Today PTW is the specialist and one of the global market leaders for manufacturing and supplying high-quality products in diagnostic radiology, nuclear medicine, radiation therapy and health physics. The quality control of X-ray images is influenced by a number of parameters. To maintain a consistent performance of X-ray installations, quality checks have to be conducted regularly. PTW offers a variety of diagnostic test tools for different X-ray devices, and therefore to reduce patient exposure and costs for X-ray departments. PTW's 'Code of Practice' defines in an easy and compact way how to perform quality control measurements on different diagnostic X-ray installations. The necessary equipment for measuring main parameters as well as acceptable limits are mentioned accordingly. The 'Code of Practice' bases on actual standards.

  4. Optimal Medical Equipment Maintenance Service Proposal Decision Support System combining Activity Based Costing (ABC) and the Analytic Hierarchy Process (AHP).

    Science.gov (United States)

    da Rocha, Leticia; Sloane, Elliot; M Bassani, Jose

    2005-01-01

    This study describes a framework to support the choice of the maintenance service (in-house or third party contract) for each category of medical equipment based on: a) the real medical equipment maintenance management system currently used by the biomedical engineering group of the public health system of the Universidade Estadual de Campinas located in Brazil to control the medical equipment maintenance service, b) the Activity Based Costing (ABC) method, and c) the Analytic Hierarchy Process (AHP) method. Results show the cost and performance related to each type of maintenance service. Decision-makers can use these results to evaluate possible strategies for the categories of equipment.

  5. Assessing the Oldness and Capacity of Radiography and Ultrasound Equipments in Tehran University of Medical Sciences

    International Nuclear Information System (INIS)

    Salamati, Payman; Ghanaati, Hossein; Ghasemzadeh, Shahram; Jalali, Amir Hossein

    2013-01-01

    Maintenance of imaging equipment is a very important part of the management of all medical imaging centers. To assess the oldness and capacity of radiography and ultrasound equipment in Tehran University of Medical Sciences. The study was performed in 16 hospitals, 4 faculties and three healthcare centers of Tehran University of Medical Sciences. We evaluated all the X-ray equipment (including the simple plain and dental, panorex, mammography, fluoroscopy and C-arm X-Ray devices) and also simple and Doppler ultrasound machines in terms of the type and usage of the device, production year, quantity of utilization, location, brand and current condition. Among fixed X-ray systems, 15 were currently in use, two were junk, two were damaged, and one was not utilized. The mean (SD) of the usage of these was 2151 (2230) cliché/month, and the mean (SD) of the oldness was 16.9 (13.6) years. The oldness of radiography equipment in our study was more than 20 years in 16, between 11 and 20 in 46, and less than 10 years in 76 devices. The mean (SD) usage (patients/month) of simple and color Doppler devices were 234.1 (365.2) and 597.5 (505.3), respectively. The oldness of ultrasonography equipment in our study was more than 11 years in 12 and less than 10 years in 55 devices. We found that 22 (15.9%) of the radiography systems and two (3%) of the ultrasonography systems had been used for more than 20 years. Radiology equipment in Tehran University of Medical Sciences have potential capacity, but they need repair, and better maintenance and management and application of standards for the imaging system needs organized supervisory mechanisms

  6. Electromagnetic interference from radio frequency identification inducing potentially hazardous incidents in critical care medical equipment

    NARCIS (Netherlands)

    Togt, R. van der; Lieshout, E.J. van; Hensbroek, R.; Beinat, E.; Binnekade, J.M.; Bakker, P.J.M.

    2008-01-01

    Context: Health care applications of autoidentification technologies, such as radio frequency identification (RFID), have been proposed to improve patient safety and also the tracking and tracing of medical equipment. However, electromagnetic interference (EMI) by RFID on medical devices has never

  7. Medical diagnostics for indoor mold exposure.

    Science.gov (United States)

    Hurraß, Julia; Heinzow, Birger; Aurbach, Ute; Bergmann, Karl-Christian; Bufe, Albrecht; Buzina, Walter; Cornely, Oliver A; Engelhart, Steffen; Fischer, Guido; Gabrio, Thomas; Heinz, Werner; Herr, Caroline E W; Kleine-Tebbe, Jörg; Klimek, Ludger; Köberle, Martin; Lichtnecker, Herbert; Lob-Corzilius, Thomas; Merget, Rolf; Mülleneisen, Norbert; Nowak, Dennis; Rabe, Uta; Raulf, Monika; Seidl, Hans Peter; Steiß, Jens-Oliver; Szewszyk, Regine; Thomas, Peter; Valtanen, Kerttu; Wiesmüller, Gerhard A

    2017-04-01

    In April 2016, the German Society of Hygiene, Environmental Medicine and Preventative Medicine (Gesellschaft für Hygiene, Umweltmedizin und Präventivmedizin (GHUP)) together with other scientific medical societies, German and Austrian medical societies, physician unions and experts has provided an AWMF (Association of the Scientific Medical Societies) guideline 'Medical diagnostics for indoor mold exposure'. This guideline shall help physicians to advise and treat patients exposed indoors to mold. Indoor mold growth is a potential health risk, even without a quantitative and/or causal association between the occurrence of individual mold species and health effects. Apart from the allergic bronchopulmonary aspergillosis (ABPA) and the mycoses caused by mold, there is only sufficient evidence for the following associations between moisture/mold damages and different health effects: Allergic respiratory diseases, asthma (manifestation, progression, exacerbation), allergic rhinitis, exogenous allergic alveolitis and respiratory tract infections/bronchitis. In comparison to other environmental allergens, the sensitizing potential of molds is estimated to be low. Recent studies show a prevalence of sensitization of 3-10% in the total population of Europe. The evidence for associations to mucous membrane irritation and atopic eczema (manifestation, progression, exacerbation) is classified as limited or suspected. Inadequate or insufficient evidence for an association is given for COPD, acute idiopathic pulmonary hemorrhage in children, rheumatism/arthritis, sarcoidosis, and cancer. The risk of infections from indoor molds is low for healthy individuals. Only molds that are capable to form toxins can cause intoxications. The environmental and growth conditions and especially the substrate determine whether toxin formation occurs, but indoor air concentrations are always very low. In the case of indoor moisture/mold damages, everyone can be affected by odor effects and

  8. Biodosimetry for medical diagnostic X-ray workers using stable chromosome aberration

    International Nuclear Information System (INIS)

    Wang Zhiquan; Liu Xuping; Li Jin

    1996-01-01

    The stable chromosome aberrations of medical diagnostic X-ray workers were analyzed using G-banding and their accumulative doses were evaluated. The results showed that the frequencies of reciprocal translocation, stable aberration and total aberration among the 4417 metaphase spread from 44 cases of medical diagnostic X-ray workers were distinctly higher than control values (P<0.05∼0.005). The stable aberration predominated strikingly in total aberration and reciprocal translocation was 57% in the stable aberrations. The medical diagnostic X-ray workers were divided into 3 groups according to calendar year of entry. The data showed that the frequencies of total aberration, stable aberration and reciprocal translocation increased with working years, especially in two groups who started working before 1970, there are statistically significant differences between the calendar year of entry before 1960 and 1960∼1969 in X-ray workers and control group. According to the equation recommended by Straume, linear coefficient (α) in linear quadratic model recommended by Schmid and the transformation coefficient by Lucas, the accumulative doses calculated are 0.58, 0.37 and 0.07 Gy for calendar year of entry before 1960, 1960∼1969 and after 1970 in X-ray workers, respectively

  9. Nordic working group for medical x-ray diagnostics: Diagnostic reference levels within xray diagnostics - experiences in the Nordic countries

    International Nuclear Information System (INIS)

    Leitz, W.; Groen, P.; Servomaa, A.; Einarsson, G.; Olerud, H.

    2003-01-01

    Medical x-ray diagnostics is one of the few applications of ionising radiation where people are irradiated on purpose. The strategy for radiation protection is also different compared to that in other areas that have the zero-alternative as its ultimate goal, meaning that no human beings at all are exposed in these practices. The focus in x-ray diagnostics concerning radiation protection is justification and optimisation. Optimisation implies that the examination is performed in such a way that the radiation dose is as small as possible without jeopardising the diagnostic security. X- ray diagnostics is a complex method where many technical parameters and methodology factors together are interacting in the determination of radiation dose and image quality. The optimisation process is not a simple and uncomplicated procedure, this difficulty is reflected in many international and national surveys showing a large spread of patient doses for one and the same type of examination. The concept diagnostic reference levels (DRL) has been introduced as a tool for reducing this wide distribution that is obviously indicating a lack of optimisation, and for cutting the highest radiation doses. In this presentation the concept for DRL and the experience gained in the Nordic countries with DRL are described. (orig.)

  10. [The diagnostic value of medical thoracoscopy for unexplained pleural effusion].

    Science.gov (United States)

    Jiang, Shu-juan; Mu, Xiao-yan; Zhang, Song; Su, Li-li; Ma, Wei-xia

    2013-05-01

    To explore the endoscopic features of patients with unexplained pleural effusion, and to evaluate the diagnostic value of medical thoracoscopy. A retrospective analysis of 2380 patients with unexplained pleural effusion (1320 males and 1060 females; age 15-94 years) in Shandong Provincial Hospital from 1992 to 2011 were performed .The diagnosis was confirmed by medical thoracoscopy. The endoscopic findings of malignant pleural effusion mostly showed nodules of varying sizes. The nodules could be grape-like, cauliflower-like, fused into masses, or diffused small nodules . The appearance of cancerous nodules was more diversified compared to tuberculous nodules. Tuberculous pleurisy was manifested as diffuse pleural congestion and miliary changes, multiple small gray-white nodules, fibrin deposition and adhesion in the pleural cavity, pleural thickening and loculation . The pathological diagnosis was as follows: pleural metastases in 899 (37.8%), primary pleural mesothelioma in 439 (18.4%), tuberculous pleurisy in 514 (21.6%), non-specific inflammation in 226 (9.5%), empyema in 190 (8.0%), hepatic pleural effusion in 36 (1.5%) and pleural effusion of unknown causes in 76 (3.2%) cases. The diagnostic positive rate of medical thoracoscopy was 96.8%. No serious complications were observed. Medical thoracoscopy is a relatively safe procedure and has an important application value in the diagnosis of unexplained pleural effusion.

  11. Radiation safety requirements for training of users of diagnostic X ...

    African Journals Online (AJOL)

    Background. Globally, the aim of requirements regarding the use and ownership of diagnostic medical X-ray equipment is to limit radiation by abiding by the 'as low as reasonably achievable' (ALARA) principle. The ignorance of radiographers with regard to radiation safety requirements, however, is currently a cause of ...

  12. Safety of Medical Diagnostic Ultrasound

    International Nuclear Information System (INIS)

    Breyer, B.

    1998-01-01

    Large numbers of people (both sick and healthy) are routinely exposed to ultrasound waves. We shall discuss wave parameters and scanner properties that are relevant to the safety aspect. This includes central pulse frequency, pulse length, intensity (ISPTA and others), focusing, pulse repetition frequency, pulse pressure, etc. Since the transmitted ultrasound power has steadily been increasing during the last two decades, the problems are becoming more serious with time. Doppler methods have gained importance and 'popularity, which additionally increases ultrasound power requirements since the reflectivity of red blood cells is so small that the backscattered pressure is about 100 times less than that from soft tissue structures in the body. Main mechanisms that can potentially present hazard are heating and cavitation. The basic parameter used to assess thermal hazard is ISPTA and the optimal predictor of cavitation hazard is the peak rarefractional pressure. The hazard of heating-up can be summarized in saying that temperatures up to 38.5 o C are safe, while temperatures above 41 o C are definitely not. Care must be taken to stay within the safe zone. However, there does not exist a confirmed report of any type of hazardous effects on humans using intensities presently applied in diagnostic ultrasound scanners. Taking this into account, various international bodies have put limits to the application of ultrasound, which is best summarized in the FDA (USA) regulation that diagnostic apparatus may have an output of maximally 720 mW/cm 2 (derated) provided thermal and mechanical properties are indicated (onscreen) by properly defined Thermal Indices (TI) and Mechanical Index (MI). These aspects shall be discussed in some detail. We shall give the rules for the operator to apply ultrasound with minimal hazard. The general conclusion is that diagnostic ultrasound, as presently known, may be used whenever a qualified expert expects essential medical benefit for the

  13. Using Survival Analysis to Evaluate Medical Equipment Battery Life.

    Science.gov (United States)

    Kuhajda, David

    2016-01-01

    As hospital medical device managers obtain more data, opportunities exist for using the data to improve medical device management, enhance patient safety, and evaluate costs of decisions. As a demonstration of the ability to use data analytics, this article applies survival analysis statistical techniques to assist in making decisions on medical equipment maintenance. The analysis was performed on a large amount of data related to failures of an infusion pump manufacturer's lithium battery and two aftermarket replacement lithium batteries from one hospital facility. The survival analysis resulted in statistical evidence showing that one of the third-party batteries had a lower survival curve than the infusion pump manufacturer's battery. This lower survival curve translates to a shorter expected life before replacement is needed. The data suggested that to limit unexpected failures, replacing batteries at a two-year interval, rather than the current industry recommendation of three years, may be warranted. For less than $5,400 in additional annual cost, the risk of unexpected battery failures can be reduced from an estimated 28% to an estimated 7%.

  14. Application of a latent variables model for the medical images analysis

    International Nuclear Information System (INIS)

    Campos S, Y.; Ruiz C, S.

    2008-01-01

    In recent years the technological advance has allowed the significant advance in diverse research fields, the medicine has not been exempt of this technology and the use of this technology has allowed a significant advance in the equipment that are used to obtain medical images. The quantity of information that is generated with this equipment has grown in exponential form and it is a difficult task to carry out a quantitative analysis of the data also the manipulation of big quantities of information makes the medical images analysis a complicated task. It is in fact this complexity what motivates this work where one of the main objectives is the analysis of techniques that allow to work with the complexity of the data generated with medical equipment. Likewise, it is wanted to illustrate an application of the peaceful uses of the nuclear energy to treat a medical problem where the diagnostic it depends essentially on the current medical equipment to give an appropriate treatment to the patients. (Author)

  15. Diagnostic Reasoning across the Medical Education Continuum

    Directory of Open Access Journals (Sweden)

    C. Scott Smith

    2014-07-01

    Full Text Available We aimed to study linguistic and non-linguistic elements of diagnostic reasoning across the continuum of medical education. We performed semi-structured interviews of premedical students, first year medical students, third year medical students, second year internal medicine residents, and experienced faculty (ten each as they diagnosed three common causes of dyspnea. A second observer recorded emotional tone. All interviews were digitally recorded and blinded transcripts were created. Propositional analysis and concept mapping were performed. Grounded theory was used to identify salient categories and transcripts were scored with these categories. Transcripts were then unblinded. Systematic differences in propositional structure, number of concept connections, distribution of grounded theory categories, episodic and semantic memories, and emotional tone were identified. Summary concept maps were created and grounded theory concepts were explored for each learning level. We identified three major findings: (1 The “apprentice effect” in novices (high stress and low narrative competence; (2 logistic concept growth in intermediates; and (3 a cognitive state transition (between analytical and intuitive approaches in experts. These findings warrant further study and comparison.

  16. Medical physics 1981

    International Nuclear Information System (INIS)

    Bunde, E.

    1982-01-01

    This volume continues the series of congress publications with which the Deutsche Gesellschaft fuer Medizinische Physik has been completely documenting its annual meetings for some years. The meeting was aimed to show the complexity not only of the scientific specialty medical physics but also of the practical activities of medical physicists, or at least give some idea of it. The conference was centred on the following points: Possibilities of optimization and methods for re-examination of techniques used in X-ray diagnostics, nuclear diagnostics and ultrasonographic diagnostics; bases of dosimetry in practical radiotherapy, especially with a view to the plans to make gauging of therapeutical dosemeters compulsory; current state of neutron therapy and dosimetry; safety and constancy of irradiation devices in operation; planning and equipment of modern radiotherapy departments. Furthermore topics from medical optics and nuclearbiological research were dealt with. Reports were given on the clinical use of whole-body counters. Climatology and surgical research were marginally dealt with in two synoptical papers. Short reports on work currently under way completed the subject groups given and allowed insight into further topical fields of work of medical physicists in science and practice. Finally, the question of education received particular interest. (orig./MG) [de

  17. Reduced medical and occupational exposures by optimizing working procedures in fluoroscopy equipment in the University Hospital of Santa Maria (RS)

    International Nuclear Information System (INIS)

    Weis, Guilherme L.; Claus, Thiago V.; Baumhardt, Tadeu; Shuch, Luiz A.

    2013-01-01

    This work seeks to reduce medical (patient) and occupational (workers) exposure by standardizing resources available in fluoroscopy equipment used in interventional procedures. Such procedures use transportable surgical arch type fluoroscopy equipment, with applications in orthopedics, angiography and pacemaker implantation. Improper use of these devices generates excessive radiation doses in both patients and the medical staff. It is observed that the equipment after being connected to the grid, is pre-selected to work in continuous fluoroscopy and no additional filtration, producing higher doses of radiation. For specific applications, changes in protocols should be undertaken according to medical indication. This work used a fluoroscopy equipment Shimadzu Active Opescope two radiation monitoring equipment, brand Radcal, models 9010 and 9015, two ionization chambers, of 60 cc and 180 cc and a low contrast phantom and a catheter, information that simulate the human body. Incidences were performed by changing the conditions of exposure as frame rates (fps - frames per second) and additional filtration. For each composition parameters was generated and filed an image, with the extent of their respective doses. These images were evaluated by radiologists. In more extreme cases we obtained a reduction of a factor 25 in occupational exposure (medical personnel) using the pulsed with the greatest 2 fps additional filter (0.3 mm Cu) compared to continuous system without any additional filtration. In medical exposure (of patients), decreased by a factor 39, the same conditions described above. With these arguments it is justified the optimization and standardization of the equipment used in fluoroscopy, which besides providing a dose reduction the patient and the medical personnel, increases the life of the X-ray tube while maintaining the quality of medical diagnosis. (author)

  18. MEDICAL DIAGNOSTICS BY MICROSTRUCTURAL ANALYSIS OF BIOLOGICAL LIQUID DRIED PATTERNS AS A PROBLEM OF BIOINFORMATICS

    Directory of Open Access Journals (Sweden)

    Petr Vladimirovich Lebedev-Stepanov, Dr.

    2018-02-01

    Full Text Available Motivation: It is important to develop the high-precision computerized methods for medical rapid diagnostic which is generalizing the unique clinical experience obtained in the past decade as specialized solutions for diagnostic problems of control of specific diseases and, potentially, for a wide health monitoring of virtually healthy population, identify the reserves of human health and take the actions to prevent of these reserves depletion. In this work we present one of the new directions in bioinformatics, i.e. medical diagnostics by automated expert system on basis of morphology analysis of digital image of biological liquid dried pattern. Results: Proposed method is combination of bioinformatics and biochemistry approaches for obtaining diagnostic information from a morphological analysis of standardized dried patterns of biological liquid sessile drop. We have carried out own research in collaboration with medical diagnostic centers and formed the electronic database for recognition the following types of diseases: candidiasis; neoplasms; diabetes mellitus; diseases of the circulatory system; cerebrovascular disease; diseases of the digestive system; diseases of the genitourinary system; infectious diseases; factors relevant to the work; factors associated with environmental pollution; factors related to lifestyle. The laboratory setup for diagnostics of the human body in pathology states is developed. The diagnostic results are considered. Availability: Access to testing the software can be obtained on request to the contact email below.

  19. MEDIC: medical embedded device for individualized care.

    Science.gov (United States)

    Wu, Winston H; Bui, Alex A T; Batalin, Maxim A; Au, Lawrence K; Binney, Jonathan D; Kaiser, William J

    2008-02-01

    Presented work highlights the development and initial validation of a medical embedded device for individualized care (MEDIC), which is based on a novel software architecture, enabling sensor management and disease prediction capabilities, and commercially available microelectronic components, sensors and conventional personal digital assistant (PDA) (or a cell phone). In this paper, we present a general architecture for a wearable sensor system that can be customized to an individual patient's needs. This architecture is based on embedded artificial intelligence that permits autonomous operation, sensor management and inference, and may be applied to a general purpose wearable medical diagnostics. A prototype of the system has been developed based on a standard PDA and wireless sensor nodes equipped with commercially available Bluetooth radio components, permitting real-time streaming of high-bandwidth data from various physiological and contextual sensors. We also present the results of abnormal gait diagnosis using the complete system from our evaluation, and illustrate how the wearable system and its operation can be remotely configured and managed by either enterprise systems or medical personnel at centralized locations. By using commercially available hardware components and software architecture presented in this paper, the MEDIC system can be rapidly configured, providing medical researchers with broadband sensor data from remote patients and platform access to best adapt operation for diagnostic operation objectives.

  20. Questionnaire-based evaluation of mobile phone interference with medical-electrical equipment in Swedish hospitals.

    Science.gov (United States)

    Wiinberg, Stig; Samuelsson, Göran; Larsson, Stefan; Nilsson, Barbro; Jönsson, Patrik X; Ivarsson, Bodil; Olofsson, Per-Åke

    2017-08-09

    National recommendations in Sweden recommend a safety distance of 3 meter (m) between mobile phones and medical-electrical (ME) equipment in hospitals. A questionnaire was used to investigate how often mobile phones were reported to interfere with ME products in clinical practice across Sweden. The results confirmed that ME equipment can be affected by mobile phone use but, the risk of the patient's outcome being affected were minimal; no cases were identified which led to injury or death. In conclusion, the results support recommendations for a general safety distance of 0.5 m between mobile phones and ME equipment in care environments.

  1. Patients Radiation Load Caused by Digitalised X-Ray Equipment

    International Nuclear Information System (INIS)

    Nikodemova, D.; Prikazska, M.; Horvathova, M.

    2001-01-01

    Full text: The radiation load of population all over the world from medical examinations clearly demonstrate the importance of implementation of quality assurance and quality control programmes into the activities of radiological departments. The basic aim of quality assurance programme is to ensure that the radiation dose is kept as low as reasonably practicable consistent with adequate image quality. As many other fields, the rapid development of techniques brought change-over from the conventional analogue technique to the digital technique. In this connection conventional X-ray film is being abandoned and images are being viewed on either laser film or monitor. The main advantages of using digital equipment lay in improved image quality and diagnostic accuracy through digital image processing, reduction in patient exposure, cost reduction by reduction film usage, more efficient storage and retrieval of radiographic images through picture archiving. Several studies that have been conducted for comparison of various diagnostic examinations performed on digital and analogue X-ray equipment have shown that in barium meal examinations, there is potential for dose saving in the digital image intensifier technique. The aim of this study was to compare measured values of dose-area product for colon investigations using different X-ray equipment types, on digital and one analogue. Our material consisted of 60 randomly selected patients, 24 of them were examined with digital equipment and 36 patients with the analogue equipment. (author)

  2. Structure of the medical digital image

    International Nuclear Information System (INIS)

    Baltadzhiev, D.

    1997-01-01

    In up-to-date medical practice diagnostic imaging techniques are the most powerful tools available to clinicians. The modern medical equipment is entirely based on digital technology. In this article the principle of generating medical images is presented. The concept for gray scale where medical images are commonly presented is described. The patterns of gray images transformation into colour scale are likewise outlined. Basic notions from medical imaging terminology such as image matrix, pixel, spatial and contrast resolution power, bit, byte and the like are explained. Also an example is given of how the binary system treats images. On the basis of digital technology the obtained medical images lend themselves readily to additional processing, reconstruction (including 3D) and storage for subsequent utilization. The ceaseless progress of computerized communications promote easy and prompt access for clinicians to the diagnostic images needed as well as realization of expert consultations by teleconference contact (author)

  3. Order No. 217 of 29 April 1977 on X-ray diagnostic equipment for medical use

    International Nuclear Information System (INIS)

    1978-01-01

    This Order was made by the National Health Service and is divided into several parts covering inter alia approval and notification of X-ray installations, conditions of liability, occupational radiation protection, construction of X-ray apparatus and its shielding and inspection of such equipment by the National Health Service. (NEA) [fr

  4. Radiation doses from medical diagnostic procedures in Canada

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, J E; Lentle, B C; Vo, C [British Columbia Univ., Vancouver, BC (Canada). Dept. of Radiology

    1997-03-01

    This document sets out to record and analyze the doses incurred in Canada from medical procedures involving the use of ionizing radiation in a typical year. Excluded are those doses incurred during therapeutic irradiation, since they differ in scale to such a large degree and because they are used almost exclusively in treating cancer. In this we are following a precedent set by the United Nations Scientific Committee on the Effects of Ionizing Radiation. Although the International Commission on Radiological Protection (ICRP) notes that dose limits should not be applied to medical exposures, it also observes that doses in different settings for the same procedure may vary by as much as two orders of magnitude, and that there are considerable opportunities for dose reductions in diagnostic radiology. Because these data do not stand in isolation the report also encompasses a review of the relevant literature and some background comment on the evolving technology of the radiological sciences. Because there is a somewhat incomplete perception of the changes taking place in diagnostic methods we have also provided some introductory explanations of the relevant technologies. In addition, there is an analysis of at least some of the limitations on the completeness of the data which are reported here. (author).

  5. Radiation doses from medical diagnostic procedures in Canada

    International Nuclear Information System (INIS)

    Aldrich, J.E.; Lentle, B.C.; Vo, C.

    1997-03-01

    This document sets out to record and analyze the doses incurred in Canada from medical procedures involving the use of ionizing radiation in a typical year. Excluded are those doses incurred during therapeutic irradiation, since they differ in scale to such a large degree and because they are used almost exclusively in treating cancer. In this we are following a precedent set by the United Nations Scientific Committee on the Effects of Ionizing Radiation. Although the International Commission on Radiological Protection (ICRP) notes that dose limits should not be applied to medical exposures, it also observes that doses in different settings for the same procedure may vary by as much as two orders of magnitude, and that there are considerable opportunities for dose reductions in diagnostic radiology. Because these data do not stand in isolation the report also encompasses a review of the relevant literature and some background comment on the evolving technology of the radiological sciences. Because there is a somewhat incomplete perception of the changes taking place in diagnostic methods we have also provided some introductory explanations of the relevant technologies. In addition, there is an analysis of at least some of the limitations on the completeness of the data which are reported here. (author)

  6. X ray spectra and qualities for use in diagnostic radiology and equipment calibration

    International Nuclear Information System (INIS)

    Souza, Karla Cristina de

    1996-12-01

    The goal of this work was the standardization of radiation qualities of diagnostic X ray equipment of the Assay Laboratory of the Institute for Radiation Protection and Dosimetry (IRD) of the National Commission of Nuclear Energy, Brazil. X ray spectra were determined from pulse height distribution measured directly on the primary beam using a high pure planar Ge detector. A program was developed to convert pulse height distribution into radiation spectra in the range from 20 to 150 keV. X ray qualities based on those used by the 'Physikalish-Technish Bundesantalt' (PTB) primary laboratory were implanted in three radiological equipment of the Assay Laboratory. These qualities simulate radiation beams on patients submitted to typical radiological examinations. Besides the spectrometric system, a reference measurement system based on an ionization chamber calibrated in air kerma was used to establish parameters such as kilovoltage, first and second half-value layer, mean energy, effective energy and inherent filtration. Our data have shown that the implantation of these radiation qualities in the Assay Laboratory results on a metrological basis for calibration of dose measurement assemblies and kV-meters, like those used by IRD to evaluate the parameters of X ray equipment around the country. A catalogue of spectral data resulting from this work is a data bank that allows various applications like dose calculation using Monte Carlo simulation techniques. (author)

  7. Vibration diagnostics and vibration alignment – effective tool to reduce the cost of repairs and maintenance of equipment

    OpenAIRE

    Пархоменко, Ю. В.

    2017-01-01

    The article discribes the following types of adjusting rotary equipment such as: balancing in own bearings, on-center alignment and shaft alignment, elimination of soft foot. The vibration alignment is based on the results of vibration diagnostics at production run of OJSC «BSW – Management Company of Holding «BMC». 

  8. Emergency Medical Service (EMS): Rotorcraft Technology Workshop

    Science.gov (United States)

    Bauchspies, J. S.; Adams, R. J.

    1981-01-01

    A lead organization on the national level should be designated to establish concepts, locations, and the number of shock trauma air medical services. Medical specialists desire a vehicle which incorporates advances in medical technology trends in health care. Key technology needs for the emergency medical services helicopter of the future include the riding quality of fixed wing aircraft (reduced noise and vibration), no tail rotor, small rotor, small rotor diameter, improved visibility, crashworthy vehicle, IFR capability, more affordability high reliability, fuel efficient, and specialized cabins to hold medical/diagnostic and communications equipment. Approaches to a national emergency medical service are discussed.

  9. Clinical Training of Medical Physicists Specializing in Diagnostic Radiology

    International Nuclear Information System (INIS)

    2010-01-01

    The application of radiation in human health, for both diagnosis and treatment of disease, is an important component of the work of the IAEA. The responsibility for the increasing technical aspects of this work is undertaken by the medical physicist. To ensure good practice in this vital area, structured clinical training programmes are required to complement academic learning. This publication is intended to be a guide to the practical implementation of such a programme for diagnostic radiology. There is a general and growing awareness that radiation medicine is increasingly dependent on well trained medical physicists based in the clinical setting. However, an analysis of the availability of medical physicists indicates a large shortfall of qualified and capable professionals. This is particularly evident in developing countries. While strategies to increase academic educational opportunities are critical to such countries, the need for guidance on structured clinical training was recognized by the members of the Regional Cooperative Agreement (RCA) for Research, Development and Training related to Nuclear Sciences for Asia and the Pacific. Consequently, a technical cooperation regional project (RAS6038) under the RCA programme was formulated to address this need in the Asia-Pacific region by developing suitable material and establishing its viability. Development of a clinical training guide for medical physicists specializing in diagnostic radiology started in 2007 with the appointment of a core drafting committee of regional and international experts. The publication drew on the experiences of clinical training programmes in Australia and New Zealand, the UK and the USA, and was moderated by physicists working in the Asian region. This publication follows the approach of the IAEA publication Training Course Series No. 37, Clinical Training of Medical Physicists specializing in Radiation Oncology. This approach to clinical training has been successfully tested

  10. MO-F-204-00: Preparing for the ABR Diagnostic and Nuclear Medical Physics Exams

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    Adequate, efficient preparation for the ABR Diagnostic and Nuclear Medical Physics exams is key to successfully obtain ABR certification. Each part of the ABR exam presents its own challenges: Part I: Determine the scope of basic medical physics study material, efficiently review this material, and solve related written questions/problems. Part II: Understand imaging principles, modalities, and systems, including image acquisition, processing, and display. Understand the relationship between imaging techniques, image quality, patient dose and safety, and solve related written questions/problems. Part III: Gain crucial, practical, clinical medical physics experience. Effectively communicate and explain the practice, performance, and significance of all aspects of clinical medical physics. All parts of the ABR exam require specific skill sets and preparation: mastery of basic physics and imaging principles; written problem solving often involving rapid calculation; responding clearly and succinctly to oral questions about the practice, methods, and significance of clinical medical physics. This symposium focuses on the preparation necessary for each part of the ABR exam. Although there is some overlap, the nuclear exam covers a different body of knowledge than the diagnostic exam. A separate speaker will address those unique aspects of the nuclear exam, and how preparing for a second specialty differs from the first. Medical physicists who recently completed each ABR exam portion will share their experiences, insights, and preparation methods to help attendees best prepare for the challenges of each part of the ABR exam. In accordance with ABR exam security policy, no recalls or exam questions will be discussed. Learning Objectives: How to prepare for Part 1 of the ABR exam by determining the scope of basic medical physics study material and related problem solving/calculations How to prepare for Part 2 of the ABR exam by understanding diagnostic and/or nuclear

  11. MO-F-204-00: Preparing for the ABR Diagnostic and Nuclear Medical Physics Exams

    International Nuclear Information System (INIS)

    2016-01-01

    Adequate, efficient preparation for the ABR Diagnostic and Nuclear Medical Physics exams is key to successfully obtain ABR certification. Each part of the ABR exam presents its own challenges: Part I: Determine the scope of basic medical physics study material, efficiently review this material, and solve related written questions/problems. Part II: Understand imaging principles, modalities, and systems, including image acquisition, processing, and display. Understand the relationship between imaging techniques, image quality, patient dose and safety, and solve related written questions/problems. Part III: Gain crucial, practical, clinical medical physics experience. Effectively communicate and explain the practice, performance, and significance of all aspects of clinical medical physics. All parts of the ABR exam require specific skill sets and preparation: mastery of basic physics and imaging principles; written problem solving often involving rapid calculation; responding clearly and succinctly to oral questions about the practice, methods, and significance of clinical medical physics. This symposium focuses on the preparation necessary for each part of the ABR exam. Although there is some overlap, the nuclear exam covers a different body of knowledge than the diagnostic exam. A separate speaker will address those unique aspects of the nuclear exam, and how preparing for a second specialty differs from the first. Medical physicists who recently completed each ABR exam portion will share their experiences, insights, and preparation methods to help attendees best prepare for the challenges of each part of the ABR exam. In accordance with ABR exam security policy, no recalls or exam questions will be discussed. Learning Objectives: How to prepare for Part 1 of the ABR exam by determining the scope of basic medical physics study material and related problem solving/calculations How to prepare for Part 2 of the ABR exam by understanding diagnostic and/or nuclear

  12. Preventing infection from reusable medical equipment: a systematic review

    Directory of Open Access Journals (Sweden)

    Hart Tony

    2002-03-01

    Full Text Available Abstract Background In 2000, the World Health Organization (WHO had eight sets of conflicting recommendations for decontaminating medical equipment. We conducted a systematic review of observational studies to assist WHO in reconciling the various guidelines. This paper summarises the methods developed and illustrates the results for three procedures – alcohol, bleach and povidone iodine. Methods We developed a Medline search strategy and applied inclusion criteria specifying the decontamination procedures of interest and an outcome of microbial destruction for a set of marker organisms. We developed protocols to assess the quality of studies and categorised them according to the reliability of the methods used. Through an iterative process we identified best practice for the decontamination methods and key additional factors required to ensure their effectiveness. We identified 88 published papers for inclusion, describing 135 separate studies of decontamination. Results For disinfection with alcohol, best practice was identified from 23 studies as an exposure to 70–80% ethanol or isopropanol for at least 5 minutes. Bleach was effective for sterilization at a concentration of 5000 ppm for 5 minutes and for disinfection at 1000 ppm for 10 minutes (33 studies. Povidone iodine was only partially effective for disinfection at a concentration of 1% for 15 minutes (15 studies. Conclusions Our findings provide an evidence base for WHO guidelines on decontaminating medical equipment. The results support the recommended use of bleach and show that alcohol could be used more widely than current guidelines suggest, provided best practice is followed. The effectiveness of povidone iodine is uncertain.

  13. 77 FR 51759 - U.S. Medical Mission to Brazil; Sao Paulo, Brazil, May 21-24, 2013

    Science.gov (United States)

    2012-08-27

    ... equipment, emergency equipment, diagnostic, physiotherapy and orthopedic, healthcare information technology... as attendees from Europe, Asia and Africa. The Medical Trade Mission to Brazil is intended to include.... Brazilian health insurance companies are responsible for paying 99% of the costs related to home care...

  14. An audit of diagnostic tests performed in medical microbiology, and ...

    African Journals Online (AJOL)

    Clinical audit is an important tool for reviewing and improving the quality of service in clinical laboratories. This is a three year audit of diagnostic test carried out in Medical Microbiology and Immunology laboratories of University of Maiduguri Teaching Hospital, Maiduguri, Nigeria. The objectives were to document and ...

  15. VIBRATION DIAGNOSTICS AND VIBRATION ALIGNMENT – EFFECTIVE TOOL TO REDUCE THE COST OF REPAIRS AND MAINTENANCE OF EQUIPMENT

    Directory of Open Access Journals (Sweden)

    Yu. V. Parkhomenko

    2017-01-01

    Full Text Available The article discribes the following types of adjusting rotary equipment such as: balancing in own bearings, on-center alignment and shaft alignment, elimination of soft foot. The vibration alignment is based on the results of vibration diagnostics at production run of OJSC «BSW – Management Company of Holding «BMC». 

  16. The evaluation of diagnostic medical exposures in the Czech Republic

    International Nuclear Information System (INIS)

    Petrova, K.; Klener, V.; Heribanova, A.; Husak, V.; Masopust, J.

    1998-01-01

    Surveys were performed in the Czech Republic to evaluate diagnostic medical exposures. The results are presented in 4 tables: (i) burden from the use of radiopharmaceuticals (examination, radiopharmaceutical, no. of procedures, average administered activity, conversion factor, collective effective dose); (ii) use of radiopharmaceuticals at nuclear medicine departments (type of examination, type of radiopharmaceutical, no. of departments, average administered activity); (iii) reference levels of administered activity specified for some diagnostic procedures for the adult patient (examination, radionuclide, chemical form, administered activity); and (iv) X-ray examinations (examination, annual no. of procedures, effective dose, age distribution, sex distribution). (P.A.)

  17. The national institute of radiation hygiene and the medical application of radiation

    International Nuclear Information System (INIS)

    Baarli, J.

    1988-01-01

    This paper gives a review of the rules and regulations concerning medical application of radiation in Norway. It discusses the intention of the regulations, the way in which the regulations is applied and how the National Institute of Radiation Hygiene as the competent authority assures the application of the regulations. The paper furthermore gives an indication of the areas of radiation application in medicine and the number of location of X-ray equipment, nuclear medical laboratories, radiation therapy equipment, etc. The number of X-ray examinations in Norway per year are also given, together with their distribution among the various types of examinations. Summary results of a quality assurance investigation of nuclear medical laboratories are given, as well as the results of inspections of the various types of equipment used in medical diagnostics

  18. Developments in medical imaging techniques

    International Nuclear Information System (INIS)

    Kramer, Cornelis

    1979-01-01

    A review of the developments in medical imaging in the past 25 years shows a strong increase in the number of physical methods which have become available for obtaining images of diagnostic value. It is shown that despite this proliferation of methods the equipment used for obtaining the images can be based on a common structure. Also the resulting images can be characterized by a few relevant parameters which indicate their information content. On the basis of this common architecture a study is made of the potential capabilities of the large number of medical imaging techniques available now and in the future. Also the requirements and possibilities for handling the images obtained and for controlling the diagnostic systems are investigated [fr

  19. Children's exposure to diagnostic medical radiation and cancer risk: epidemiologic and dosimetric considerations

    International Nuclear Information System (INIS)

    Linet, Martha S.; Rajaraman, Preetha; Kim, Kwang pyo

    2009-01-01

    While the etiology of most childhood cancers is largely unknown, epidemiologic studies have consistently found an association between exposure to medical radiation during pregnancy and risk of childhood cancer in offspring. The relation between early life diagnostic radiation exposure and occurrence of pediatric cancer risks is less clear. This review summarizes current and historical estimated doses for common diagnostic radiologic procedures as well as the epidemiologic literature on the role of maternal prenatal, children's postnatal and parental preconception diagnostic radiologic procedures on subsequent risk of childhood malignancies. Risk estimates are presented according to factors such as the year of birth of the child, trimester and medical indication for the procedure, and the number of films taken. The paper also discusses limitations of the methods employed in epidemiologic studies to assess pediatric cancer risks, the effects on clinical practice of the results reported from the epidemiologic studies, and clinical and public health policy implications of the findings. Gaps in understanding and additional research needs are identified. Important research priorities include nationwide surveys to estimate fetal and childhood radiation doses from common diagnostic procedures, and epidemiologic studies to quantify pediatric and lifetime cancer risks from prenatal and early childhood exposures to diagnostic radiography, CT, and fluoroscopically guided procedures. (orig.)

  20. Design of point-of-care (POC) microfluidic medical diagnostic devices

    Science.gov (United States)

    Leary, James F.

    2018-02-01

    Design of inexpensive and portable hand-held microfluidic flow/image cytometry devices for initial medical diagnostics at the point of initial patient contact by emergency medical personnel in the field requires careful design in terms of power/weight requirements to allow for realistic portability as a hand-held, point-of-care medical diagnostics device. True portability also requires small micro-pumps for high-throughput capability. Weight/power requirements dictate use of super-bright LEDs and very small silicon photodiodes or nanophotonic sensors that can be powered by batteries. Signal-to-noise characteristics can be greatly improved by appropriately pulsing the LED excitation sources and sampling and subtracting noise in between excitation pulses. The requirements for basic computing, imaging, GPS and basic telecommunications can be simultaneously met by use of smartphone technologies, which become part of the overall device. Software for a user-interface system, limited real-time computing, real-time imaging, and offline data analysis can be accomplished through multi-platform software development systems that are well-suited to a variety of currently available cellphone technologies which already contain all of these capabilities. Microfluidic cytometry requires judicious use of small sample volumes and appropriate statistical sampling by microfluidic cytometry or imaging for adequate statistical significance to permit real-time (typically medical decisions for patients at the physician's office or real-time decision making in the field. One or two drops of blood obtained by pin-prick should be able to provide statistically meaningful results for use in making real-time medical decisions without the need for blood fractionation, which is not realistic in the field.

  1. Image processing for medical diagnosis of human organs

    International Nuclear Information System (INIS)

    Tamura, Shin-ichi

    1989-01-01

    The report first describes expectations and needs for diagnostic imaging in the field of clinical medicine, radiation medicine in particular, viewed by the author as an image processing expert working at a medical institute. Then, medical image processing techniques are discussed in relation to advanced information processing techniques that are currently drawing much attention in the field of engineering. Finally, discussion is also made of practical applications of image processing techniques to diagnosis. In the field of clinical diagnosis, advanced equipment such as PACS (picture archiving and communication system) has come into wider use, and efforts have been made to shift from visual examination to more quantitative and objective diagnosis by means of such advanced systems. In clinical medicine, practical, robust systems are more useful than sophisticated ones. It is difficult, though important, to develop completely automatized diagnostic systems. The urgent, realistic goal, therefore, is to develop effective diagnosis support systems. In particular, operation support systems equipped with three-dimensional displays will be very useful. (N.K.)

  2. TU-G-213-00: The International Electrotechnical Commission (IEC): What Is It and Why Should Medical Physicists Care?

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-06-15

    The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists.

  3. Teaching Critical Thinking in Graduate Medical Education: Lessons Learned in Diagnostic Radiology.

    Science.gov (United States)

    Morrissey, Benjamin; Heilbrun, Marta E

    2017-01-01

    The 2014 Institute of Medicine report, Graduate Medical Education that Meets the Nation's Health Needs , challenged the current graduate medical training process and encouraged new opportunities to redefine the fundamental skills and abilities of the physician workforce. This workforce should be skilled in critically evaluating the current systems to improve care delivery and health. To meet these goals, current challenges, motivations, and educational models at the medical school and graduate medical education levels related to formal training in nonclinical aspects of medicine, especially critical thinking, are reviewed. Our diagnostic radiology training program is presented as a "case study" to frame the review.

  4. Managing medical equipment used by technology-dependent children: evaluation of an instructional tool for pediatric residents and medical students.

    Science.gov (United States)

    Jackson, Jennifer M; Radulovic, Andrea; Nageswaran, Savithri

    2012-08-01

    To evaluate the effectiveness of a workshop on managing medical devices used in technology-dependent children. Study participants included residents and medical students rotating in the pediatrics department at the time of the study. A workshop was conducted consisting of learning stations for common medical devices, including brief presentations and opportunities for hands-on practice with each device. Participants completed surveys before and after the workshop assessing their perceived ability to manage medical equipment before and after the workshop and their ongoing learning needs. All participants indicated a substantial need for training on how to manage medical devices used by technology-dependent patients. Scores for perceived ability to manage the devices improved significantly after workshop participation for nearly all devices taught. Medical trainees have significant learning needs for managing devices used by technology-dependent patients. Hands-on, small-group training can be an effective instructional tool for improving confidence in these skills.

  5. Exposure criteria for medical diagnostic ultrasound: 1, Criteria based on thermal mechanisms

    International Nuclear Information System (INIS)

    1992-01-01

    A previous report (NCRP, 1983) contains a comprehensive review of biological effects and mechanisms of action of ultrasound and an analysis of their implications for medical ultrasound. This Report presents background material for a scientifically-based approach to safety assessment of ultrasound. It is intended to help the medical community take advantage of new developments, while maintaining the excellent safety record which now exists for diagnostic ultrasound

  6. SU-E-P-01: An Informative Review On the Role of Diagnostic Medical Physicist in the Academic and Private Medical Centers

    International Nuclear Information System (INIS)

    Weir, V; Zhang, J

    2014-01-01

    Purpose: The role of physicist in the academic and private hospital environment continues to evolve and expand. This becomes more obvious with the newly revised requirements of the Joint Commission (JC) on imaging modalities and the continued updated requirements of ACR accreditation for medical physics (i.e., starting in June 2014, a physicists test will be needed before US accreditation). We provide an informative review on the role of diagnostic medical physicist and hope that our experience will expedite junior physicists in understanding their role in medical centers, and be ready to more opportunities. Methods: Based on our experience, diagnostic medical physicists in both academic and private medical centers perform several clinical functions. These include providing clinical service and physics support, ensuring that all ionizing radiation devices are tested and operated in compliance with the State and Federal laws, regulations and guidelines. We also discuss the training and education required to ensure that the radiation exposure to patients and staff is as low as reasonably achievable. We review the overlapping roles of medical and health physicist in some institutions. Results: A detailed scheme on the new requirements (effective 7/1/2014) of the JC is provided. In 2015, new standards for fluoroscopy, cone beam CT and the qualifications of staff will be phased in. A summary of new ACR requirements for different modalities is presented. Medical physicist have other duties such as sitting on CT and fluoroscopy committees for protocols design, training of non-radiologists to meet the new fluoroscopy rules, as well as helping with special therapies such as Yittrium 90 cases. Conclusion: Medical physicists in both academic and private hospitals are positioned to be more involved and prominent. Diagnostic physicists need to be more proactive to involve themselves in the day to day activities of the radiology department

  7. SU-E-P-01: An Informative Review On the Role of Diagnostic Medical Physicist in the Academic and Private Medical Centers

    Energy Technology Data Exchange (ETDEWEB)

    Weir, V [Baylor Health Care System, Dallas, TX (United States); Zhang, J [University of Kentucky, Lexington, KY (United States)

    2014-06-01

    Purpose: The role of physicist in the academic and private hospital environment continues to evolve and expand. This becomes more obvious with the newly revised requirements of the Joint Commission (JC) on imaging modalities and the continued updated requirements of ACR accreditation for medical physics (i.e., starting in June 2014, a physicists test will be needed before US accreditation). We provide an informative review on the role of diagnostic medical physicist and hope that our experience will expedite junior physicists in understanding their role in medical centers, and be ready to more opportunities. Methods: Based on our experience, diagnostic medical physicists in both academic and private medical centers perform several clinical functions. These include providing clinical service and physics support, ensuring that all ionizing radiation devices are tested and operated in compliance with the State and Federal laws, regulations and guidelines. We also discuss the training and education required to ensure that the radiation exposure to patients and staff is as low as reasonably achievable. We review the overlapping roles of medical and health physicist in some institutions. Results: A detailed scheme on the new requirements (effective 7/1/2014) of the JC is provided. In 2015, new standards for fluoroscopy, cone beam CT and the qualifications of staff will be phased in. A summary of new ACR requirements for different modalities is presented. Medical physicist have other duties such as sitting on CT and fluoroscopy committees for protocols design, training of non-radiologists to meet the new fluoroscopy rules, as well as helping with special therapies such as Yittrium 90 cases. Conclusion: Medical physicists in both academic and private hospitals are positioned to be more involved and prominent. Diagnostic physicists need to be more proactive to involve themselves in the day to day activities of the radiology department.

  8. Proposed limiting values for performance criteria in acceptance testing of diagnostic X-ray equipment in the Federal Republic of Germany

    International Nuclear Information System (INIS)

    Baeuml, A.

    1989-01-01

    In the Federal Republic of Germany a new X-ray ordinance came into force in 1988 containing a specific paragraph on quality assurance for all medical X-ray units stipulating acceptance tests, regular checks and supervision by medical bodies and the competent authorities. Acceptance testing is to be performed by engineers from equipment suppliers of manufacturers in new and existing installations. It is expected that the service engineers will adjust the equipment in such a way as to obtain optimal performance before measurements are made, the results of which are to be stated in a certificate describing quality status of the equipment. A working group has developed guidelines for these acceptance tests. Items to be measured are reported and proposed limiting values and their tolerances are discussed. (author)

  9. Proposed limiting values for performance criteria in acceptance testing of diagnostic X-ray equipment in the Federal Republic of Germany

    International Nuclear Information System (INIS)

    Baeuml, A.

    1989-01-01

    In the Federal Republic of Germany a new X-ray ordinance came into force in 1988 containing a specific paragraph on quality assurance for all medical X-ray units stipulating acceptance tests, regular checks and supervision by medical bodies and the competent authorities. Acceptance testing is to be performed by engineers from the equipment suppliers or manufacturers in new and also existing installations. It is expected that the service engineers will adjust the equipment in such a way as to obtain optimal performance before measurements are made, the results of which are to be stated in a certificate describing the quality status of the equipment. A working group has developed guidelines for these acceptance tests. The items to be measured are reported and the proposed limiting values and their tolerances are discussed. (author)

  10. A special ionisation chamber for quality control of diagnostic and mammography X ray equipment

    International Nuclear Information System (INIS)

    Costa, A.M.; Caldas, L.V.E.

    2003-01-01

    A quality control program for X ray equipment used for conventional radiography and mammography requires the constancy check of the beam qualities in terms of the half-value layers. In this work, a special double-faced parallel-plate ionisation chamber was developed with inner electrodes of different materials, in a tandem system. Its application will be in quality control programs of diagnostic and mammography X ray equipment for confirmation of half-value layers previously determined by the conventional method. Moreover, the chamber also may be utilised for measurements of air kerma values (and air kerma rates) in X radiation fields used for conventional radiography and mammography. The chamber was studied in relation to the characteristics of saturation, ion collection efficiency, polarity effects, leakage current, and short-term stability. The energy dependence in response of each of the two faces of the chamber was determined over the conventional radiography and mammography X ray ranges (unattenuated beams). The different energy responses of the two faces of the chamber allowed the formation of a tandem system useful for the constancy check of beam qualities. (author)

  11. A special ionisation chamber for quality control of diagnostic and mammography X ray equipment.

    Science.gov (United States)

    Costa, A M; Caldas, L V E

    2003-01-01

    A quality control program for X ray equipment used for conventional radiography and mammography requires the constancy check of the beam qualities in terms of the half-value layers. In this work, a special double-faced parallel-plate ionisation chamber was developed with inner electrodes of different materials, in a tandem system. Its application will be in quality control programs of diagnostic and mammography X ray equipment for confirmation of half-value layers previously determined by the conventional method. Moreover, the chamber also may be utilised for measurements of air kerma values (and air kerma rates) in X radiation fields used for conventional radiography and mammography. The chamber was studied in relation to the characteristics of saturation, ion collection efficiency, polarity effects, leakage current, and short-term stability. The energy dependence in response of each of the two faces of the chamber was determined over the conventional radiography and mammography X ray ranges (unattenuated beams). The different energy response of the two faces of the chamber allowed the formation of a tandem system useful for the constancy check of beam qualities.

  12. A diagnostic methodology for refrigerating systems; Methodologie de diagnostic des installations frigorifiques

    Energy Technology Data Exchange (ETDEWEB)

    Vrinat, G. [Association Francaise du Froid (AFF), 75 - Paris (France)

    1997-12-31

    A diagnostic methodology for refrigerating machines, equipment and plants has been defined and evaluated for EDF, the French national power utility and ADEME, the French Agency for Energy Conservation, in the framework of energy conservation objectives: the diagnostic method should enable to identify malfunctions, assess the cost efficiency of the equipment, identify limiting factors, and consider corrective measures

  13. Radiation protection in medical diagnostic radiology in the city of Sobral, Brazil

    International Nuclear Information System (INIS)

    Menezes, F.L.; Paschoal, C.M.M.; Ferreira, F.C.L.; Alcantara, M.C.

    2015-01-01

    The objective of this study was to evaluate the suitability to radiation protection of four diagnostic radiology medical services in the city of Sobral-CE, Northeast of Brazil, and to analyze results of the literature for the cities of Rio Branco-AC, North of Brazil, and Rio de Janeiro-RJ, South-east of Brazil. In Sobral-CE, it was performed interviews and direct observations with reference to Brazilian law, the National Ordinance No.453/1998 of the Ministry of Health that regulates the operation of medical and odontological diagnostic radiology services. The results show the occurrence of many items in disagreement with the standard. The technical and operational infractions have basically due to unfamiliarity with the legislation, the lack of investment in training and/or professional development courses. (authors)

  14. Effects of job stress on hypertension among medical diagnostic X-ray workers in China

    International Nuclear Information System (INIS)

    Zhao Zhigang; Wang Jixian; Zhao Yongcheng; Zhang Wei

    2004-01-01

    Objective: To study the relation between job stress and hypertension among medical diagnostic x-ray workers in China. Methods: A total of 264 confirmed cases of hypertension were selected among medical diagnostic X-ray workers from 10 provinces and cities. A case-control study with 1:2 matched pair was conducted. Job stress was defined according to Siegrist effort-reward imbalance model. Results: High imbalance ,high overcommitment and severe work environment were associated with enhanced hypertension risk significantly. The OR was 1.848 (P=0.018), 2.058 (P=0.000) and 1.797 (P=0.008) for imbalance, overcommitment and severe work environment, respectively. After controlling other risk factors, the relation still remained significant. Conclusion: The main work-related risk factors causing hypertension among diagnostic X-ray workers are effort-reward imbalance, overcommitment and severe work environment. (authors)

  15. Relativity Screens for Misvalued Medical Services: Impact on Noninvasive Diagnostic Radiology.

    Science.gov (United States)

    Rosenkrantz, Andrew B; Silva, Ezequiel; Hawkins, C Matthew

    2017-11-01

    In 2006, the AMA/Specialty Society Relative Value Scale Update Committee (RUC) introduced ongoing relativity screens to identify potentially misvalued medical services for payment adjustments. We assess the impact of these screens upon the valuation of noninvasive diagnostic radiology services. Data regarding relativity screens and relative value unit (RVU) changes were obtained from the 2016 AMA Relativity Assessment Status Report. All global codes in the 2016 Medicare Physician Fee Schedule with associated work RVUs were classified as noninvasive diagnostic radiology services versus remaining services. The frequency of having ever undergone a screen was compared between the two groups. Screened radiology codes were further evaluated regarding the RVU impact of subsequent revaluation. Of noninvasive diagnostic radiology codes, 46.0% (201 of 437) were screened versus 22.2% (1,460 of 6,575) of remaining codes (P < .001). Most common screens for which radiology codes were identified as potentially misvalued were (1) high expenditures (27.5%) and (2) high utilization (25.6%). The modality and body region most likely to be identified in a screen were CT (82.1%) and breast (90.9%), respectively. Among screened radiology codes, work RVUs, practice expense RVUs, and nonfacility total RVUs decreased in 20.3%, 65.9%, and 75.3%, respectively. All screened CT, MRI, brain, and spine codes exhibited decreased total RVUs. Policymakers' ongoing search for potentially misvalued medical services has disproportionately impacted noninvasive diagnostic radiology services, risking the introduction of unintended or artificial shifts in physician practice. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  16. Small Portable Analyzer Diagnostic Equipment (SPADE) Program -- Diagnostic Software Validation

    Science.gov (United States)

    1984-07-01

    Electronic Equipment Electromagnetic Emission and Susceptibility Requirements for the Control of Electromagnetic Interference Electromagnetic...ONLY. ORIENTATION OF DEFECT LOOKING HHO QIlILL: t -ed’-o· Significant efforts were expended to simulate spalling failures associated with naturally

  17. Mamma diagnostics for MTRA (medical-radiological personnel)/RT (radiologists); Mammadiagnostik fuer MTRA/RT

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Uwe; Baum, Friedemann

    2014-07-01

    The text book on mamma diagnostics for MTRA (medical-radiological personnel)/RT (radiologists) covers the following issues: Anatomy, development and physiology of mammary glands; tumor development an breast cancer risk; pathology, non-imaging diagnostics; mammography: physical-technical fundamentals; mammography: analogue technique; mammography: digital technique; mammography: quality assurance; mammography: legal questions and radiation protection; mammography: new developments; mammography: setting technique; mammography: use and appraisal; mamma-sonography: technique and methodology; mamma-sonography: assignment and appraisal, mamma-NMR: technique and methodology; mamma-NMR: assignment and appraisal lymph node diagnostics; mamma interventions; biopsy; mamma interventions: marking examination concepts; therapeutic concepts; hygienic concepts; communication and interaction.

  18. Diagnostic technology of PWR plant equipment failures

    International Nuclear Information System (INIS)

    Nakamura, Tetsuo; Tanaka, Mamoru; Okamachi, Masao; Taguchi, Shozo; Nagashima, Kazuhiro; Ishikawa, Satoshi

    1985-01-01

    To confirm the soundness of the important facilities in a nuclear power plant contributes to the reliability of the plant operations and improvement of its operation rate. For this purpose, the following diagnostic techniques have been developed. (1). Vibration and loose parts monitoring: Detection of abnormal structural vibrations in the reactor, estimation of its mode, detection of loose parts in the primary system, and estimation of the position and energy of their collisions against the reactor vessel or the like. (2). Valve leak monitoring: Detection of leaks from primary valves in the primary cooling boundary, such as the pressurizer relief valve and safety valve, and estimation of the form of the leaks. (3). Detector noise response diagnosis: Diagnosis of degradation of principal process detectors during plant operation. Furthermore, a diagnostic system incorporating the above diagnostic technology applicable to actual plants has been experimentally manufactured and successfully verified. (author)

  19. A novel approach to collaborative product development in the medical-equipment industry

    OpenAIRE

    Tseng, Kevin C; Chien-Lung, Hsu

    2013-01-01

    In this study, we summarise the requirements for collaborative product development based on our investigation of the differences in the resources and tools that are needed for the various stages of collaborative product development and the needs of system users during these various stages. We proposed a user-oriented approach of collaborative product development for medical equipment and designed a collaborative product development system with the required functionalities to satisfy different...

  20. The role of medical physicist in radiation protection

    International Nuclear Information System (INIS)

    Nusslin, F.

    2010-01-01

    Ionizing Radiation is applied in Radiation Therapy, Nuclear medicine and Diagnostic Radiology. Radiation Protection in Medical Application of Ionizing Radiation requires specific Professional Competence in all relevant details of the radiation source instrumentation / equipment clinical dosimetry application procedures quality assurance medical risk-benefit assessment. Application in general include Justification of practices (sufficient benefit to the exposed individuals) Limitation of doses to individuals (occupational / public exposure) Optimization of Protection (magnitude and likelihood of exposures, and the number of individuals exposed will be ALARA. Competence of persons is normally assessed by the State by having a formal mechanism for registration, accreditation or certification of medical physicists in the various specialties (e.g. diagnostic radiology, radiation therapy, nuclear medicine). The patient safety in the use of medical radiation will be increased through: Consistent education and certification of medical team members, whose qualifications are recognized nationally, and who follow consensus practice guidelines that meet established national accrediting standards

  1. X-ray medical diagnostics and thyroid cancer

    International Nuclear Information System (INIS)

    Tsenova, T.; Chobanova, N.; Pavlova, A; Bajrakova, A.

    1998-01-01

    An analytical epidemiological study for assessment of X-ray medical diagnosis as a risk factor for thyroid cancer (TC) has been carried out. The data from the investigation of 90 TC cases and 180 controls matched by sex and age are used. The risk assessment is based on the distribution of investigated persons according to thyroid gland irradiation (as an equivalent dose cumulated from the procedures) and the number of different procedures of organs and systems. There is a significantly increased risk for TC from diagnostic lung examinations; fluoroscopy (OR=3.49, 95% CI=1.66±7.39, p=0.0002) and radiography (OR=2.48, 95% CI=1.05±5.86, p=0.02) (author)

  2. Quality control: a measure for optimization of dose in diagnostic radiology

    International Nuclear Information System (INIS)

    Abd Aziz Mhd Ramli; Muhammad Jamal Md Isa; Husaini Salleh

    2002-01-01

    Patient dose should always be a factor that is taken into account when using diagnostic X-ray equipment. There is no doubt that patients receive vastly different radiation doses for same examination under different circumstances and performance as well as safety standard of X-ray generating machine is one of the possible causes for this. MINT's experience in measuring performance and safety standard of X-ray fluoroscopic equipments in the year of 2000 indicated that 70% of the irradiating apparatus tend to deliver unnecessary exposures to patients due to various causes. Improper calibration and the usage of unoptimized fluoroscopic X-ray equipment are identified as two major causes that lead to unoptimized medical exposures to patient

  3. Health Technology Assessment for Molecular Diagnostics: Practices, Challenges, and Recommendations from the Medical Devices and Diagnostics Special Interest Group.

    Science.gov (United States)

    Garfield, Susan; Polisena, Julie; S Spinner, Daryl; Postulka, Anne; Y Lu, Christine; Tiwana, Simrandeep K; Faulkner, Eric; Poulios, Nick; Zah, Vladimir; Longacre, Michael

    2016-01-01

    Health technology assessments (HTAs) are increasingly used to inform coverage, access, and utilization of medical technologies including molecular diagnostics (MDx). Although MDx are used to screen patients and inform disease management and treatment decisions, there is no uniform approach to their evaluation by HTA organizations. The International Society for Pharmacoeconomics and Outcomes Research Devices and Diagnostics Special Interest Group reviewed diagnostic-specific HTA programs and identified elements representing common and best practices. MDx-specific HTA programs in Europe, Australia, and North America were characterized by methodology, evaluation framework, and impact. Published MDx HTAs were reviewed, and five representative case studies of test evaluations were developed: United Kingdom (National Institute for Health and Care Excellence's Diagnostics Assessment Programme, epidermal growth factor receptor tyrosine kinase mutation), United States (Palmetto's Molecular Diagnostic Services Program, OncotypeDx prostate cancer test), Germany (Institute for Quality and Efficiency in Healthcare, human papillomavirus testing), Australia (Medical Services Advisory Committee, anaplastic lymphoma kinase testing for non-small cell lung cancer), and Canada (Canadian Agency for Drugs and Technologies in Health, Rapid Response: Non-invasive Prenatal Testing). Overall, the few HTA programs that have MDx-specific methods do not provide clear parameters of acceptability related to clinical and analytic performance, clinical utility, and economic impact. The case studies highlight similarities and differences in evaluation approaches across HTAs in the performance metrics used (analytic and clinical validity, clinical utility), evidence requirements, and how value is measured. Not all HTAs are directly linked to reimbursement outcomes. To improve MDx HTAs, organizations should provide greater transparency, better communication and collaboration between industry and HTA

  4. Prior use of durable medical equipment as a risk adjuster for health-based capitation

    NARCIS (Netherlands)

    R.C. van Kleef (Richard); R.C.J.A. van Vliet (René)

    2010-01-01

    textabstractThis paper examines a new risk adjuster for capitation payments to Dutch health plans, based on the prior use of durable medical equipment (DME). The essence is to classify users of DME in a previous year into clinically homogeneous classes and to apply the resulting classification as a

  5. General guidelines about performance specifications for purchasing equipment for x-ray diagnostics, with comments

    International Nuclear Information System (INIS)

    1995-12-01

    These general guidelines are intended to be used as a basis for what requirements are reasonable from a radiation protection point of view and should be part of the contract in connection with the purchase of equipment for x-ray diagnostics. Technical performance requirements are addressed as well as items like documentation, instructions for use and education and training. The guidelines are also useful for the design of quality assurance programs. In the comments in addition to these guidelines legal aspects are noted, including a list of relevant laws, regulations and directives. Standards, both national and international, within the field are referred to with a short description of their content. 40 refs

  6. General guidelines about performance specifications for purchasing equipment for x-ray diagnostics, with comments

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-01

    These general guidelines are intended to be used as a basis for what requirements are reasonable from a radiation protection point of view and should be part of the contract in connection with the purchase of equipment for x-ray diagnostics. Technical performance requirements are addressed as well as items like documentation, instructions for use and education and training. The guidelines are also useful for the design of quality assurance programs. In the comments in addition to these guidelines legal aspects are noted, including a list of relevant laws, regulations and directives. Standards, both national and international, within the field are referred to with a short description of their content. 40 refs.

  7. Effects of electromagnetic interference on the functional usage of medical equipment by 2G/3G/4G cellular phones: A revie

    Directory of Open Access Journals (Sweden)

    Periyasamy M. Mariappan

    2016-09-01

    Full Text Available There has been an increase in the potential use of wireless devices in healthcare domain for a variety of reasons. The most commonly used device is the cellular phone, which emits strong electromagnetic energy affecting thereby the functionality of the vital medical equipment such as ventilators, ECG monitors, cardiac monitors, and defibrillators. This prompted the healthcare concerns to restrict the use of these phones in the proximity of critical and non-critical care medical equipment. Due to the developments made in the design of medical equipment to comply with the EMC standards, the restriction had been slowly laid off. Still, the researchers are concerned about the electromagnetic interference with medical devices by cellular phones in the healthcare domain and recommend for conducting continuous research to study their interaction with medical equipment. This paper overviews the certain investigations carried out in the recent years to study the electromagnetic interference between medical devices and 2G/3G/4G LTE cellular phones. During the initial development of cellular phones, the 2G cellular phones had caused more interference that affects the function and operation of some medical devices. The possibility of interference from 3G cellular phones with medical devices was considerably lower than the 2G phones, but still exists. Furthermore, almost all of the 4G phones have little to no interference with the medical devices. Currently, with the development of the medical devices industry, the current medical devices are designed to operate safely under any conditions of usage. Finally, a careful analysis would require statistics on the frequency of adverse events across the healthcare system, which apparently do not exist.

  8. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Science.gov (United States)

    2010-10-01

    ... Procedural Terminology published by the American Medical Association. (3) Levels of supervision. Except where... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  9. Advanced signal processing theory and implementation for sonar, radar, and non-invasive medical diagnostic systems

    CERN Document Server

    Stergiopoulos, Stergios

    2009-01-01

    Integrates topics of signal processing from sonar, radar, and medical system technologies by identifying their concept similarities. This book covers non-invasive medical diagnostic system applications, including intracranial ultrasound, a technology that attempts to address non-invasive detection on brain injuries and stroke.

  10. Synthetic biology devices for in vitro and in vivo diagnostics.

    Science.gov (United States)

    Slomovic, Shimyn; Pardee, Keith; Collins, James J

    2015-11-24

    There is a growing need to enhance our capabilities in medical and environmental diagnostics. Synthetic biologists have begun to focus their biomolecular engineering approaches toward this goal, offering promising results that could lead to the development of new classes of inexpensive, rapidly deployable diagnostics. Many conventional diagnostics rely on antibody-based platforms that, although exquisitely sensitive, are slow and costly to generate and cannot readily confront rapidly emerging pathogens or be applied to orphan diseases. Synthetic biology, with its rational and short design-to-production cycles, has the potential to overcome many of these limitations. Synthetic biology devices, such as engineered gene circuits, bring new capabilities to molecular diagnostics, expanding the molecular detection palette, creating dynamic sensors, and untethering reactions from laboratory equipment. The field is also beginning to move toward in vivo diagnostics, which could provide near real-time surveillance of multiple pathological conditions. Here, we describe current efforts in synthetic biology, focusing on the translation of promising technologies into pragmatic diagnostic tools and platforms.

  11. A study on developpement of guideline on writing technical document for electrical medical devices: Dental x-ray equipment

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Youl; Kim, Jae Ryang; Lee, Jun Ho; Park, Chang Won [Division of Medical Device Research, National Institute of Food and Drug Safety Evaluation, Mnistry of Food and Drug Safety (Korea, Republic of)

    2016-12-15

    Due to recent population aging, the number of check-up for senior citizens has increased steadily. According to this trend, the market size of dental X-ray equipment and the number of approval and review for these devices have simultaneously increased. The technical document of medical device is required for approval and review for medical device, and medical device companies needs to have work comprehension and expertise, as the document needs to include the overall contents such as performances, test criteria, etc.. Yet, since most of domestic manufacturers or importers of medical devices are small businesses, it is difficult for them to recruit professional manpower for approval of medical devices, and submission of inaccurate technical documents has increased. These problems lead to delay of the approval process and to difficulties in quick entering into the market. Especially, the Ministry of Food and Drug safety (MFDS) standards of a dental extra-oral X-ray equipment, a dental intra-oral X-ray equipment, an arm-type computed tomography, and a portable X-ray system have been recently enacted or not. this guideline of dental X-ray equipment adjusting revised standards was developed to help relative companies and reviewers. For this study, first, the methods to write technical document have been reviewed with revised international and domestic regulations and system. Second, the domestic and foreign market status of each item has been surveyed and analyzed. Third, the contents of technical documents already approved by MFDS have been analyzed to select the correct example, test items, criteria, and methods. Finally, the guideline has been developed based on international and domestic regulation, through close review of a consultative body composed of academic, industrial, research institute and government experts.

  12. A study on developpement of guideline on writing technical document for electrical medical devices: Dental x-ray equipment

    International Nuclear Information System (INIS)

    Lee, Seung Youl; Kim, Jae Ryang; Lee, Jun Ho; Park, Chang Won

    2016-01-01

    Due to recent population aging, the number of check-up for senior citizens has increased steadily. According to this trend, the market size of dental X-ray equipment and the number of approval and review for these devices have simultaneously increased. The technical document of medical device is required for approval and review for medical device, and medical device companies needs to have work comprehension and expertise, as the document needs to include the overall contents such as performances, test criteria, etc.. Yet, since most of domestic manufacturers or importers of medical devices are small businesses, it is difficult for them to recruit professional manpower for approval of medical devices, and submission of inaccurate technical documents has increased. These problems lead to delay of the approval process and to difficulties in quick entering into the market. Especially, the Ministry of Food and Drug safety (MFDS) standards of a dental extra-oral X-ray equipment, a dental intra-oral X-ray equipment, an arm-type computed tomography, and a portable X-ray system have been recently enacted or not. this guideline of dental X-ray equipment adjusting revised standards was developed to help relative companies and reviewers. For this study, first, the methods to write technical document have been reviewed with revised international and domestic regulations and system. Second, the domestic and foreign market status of each item has been surveyed and analyzed. Third, the contents of technical documents already approved by MFDS have been analyzed to select the correct example, test items, criteria, and methods. Finally, the guideline has been developed based on international and domestic regulation, through close review of a consultative body composed of academic, industrial, research institute and government experts

  13. Automated Risk Control in Medical Imaging Equipment Management Using Cloud Application

    Directory of Open Access Journals (Sweden)

    Sally M. Ghanem

    2018-01-01

    Full Text Available Medical imaging equipment (MIE is the baseline of providing patient diagnosis in healthcare facilities. However, that type of equipment poses high risk for patients, operators, and environment in terms of technology and application. Considering risk management in MIE management is rarely covered in literature. The study proposes a methodology that controls risks associated with MIE management. The methodology is based on proposing a set of key performance indicators (KPIs that lead to identify a set of undesired events (UDEs, and through a risk matrix, a risk level is evaluated. By using cloud computing software, risks could be controlled to be manageable. The methodology was verified by using a data set of 204 pieces of MIE along 104 hospitals, which belong to Egyptian Ministry of Health. Results point to appropriateness of proposed KPIs and UDEs in risk evaluation and control. Thus, the study reveals that optimizing risks taking into account the costs has an impact on risk control of MIE management.

  14. [The Offer of Medical-Diagnostic Self-Tests on German Language Websites: Results of a Systematic Internet Search].

    Science.gov (United States)

    Kuecuekbalaban, P; Schmidt, S; Muehlan, H

    2018-03-01

    The aim of the current study was to provide an overview of medical-diagnostic self-tests which can be purchased without a medical prescription on German language websites. From September 2014 to March 2015, a systematic internet research was conducted with the following search terms: self-test, self-diagnosis, home test, home diagnosis, quick test, rapid test. 513 different self-tests for the diagnostics of 52 diverse diseases or health risks were identified, including chronic diseases (e. g. diabetes, chronic disease of the kidneys, liver, and lungs), sexually transmitted diseases (e. g. HIV, chlamydia, gonorrhea), infectious diseases (e. g. tuberculosis, malaria, Helicobacter pylori), allergies (e. g. house dust, cats, histamine) and cancer as well as tests for the diagnostics of 12 different psychotropic substances. These were sold by 90 companies in Germany and by other foreign companies. The number of medical-diagnostic self-tests which can be bought without a medical prescription on the Internet has increased enormously in the last 10 years. Further studies are needed for the identification of the determinants of the use of self-tests as well as the impact of the application on the experience and behavior of the user. © Georg Thieme Verlag KG Stuttgart · New York.

  15. The analysis of distribution of the chromosome aberration breakpoints from medical diagnostic X-ray workers

    International Nuclear Information System (INIS)

    Wang Qin; Li Jin; Tang Weisheng; Wang Zhiquan

    2003-01-01

    Objective: To analyze the distribution of the chromosome aberration breakpoints from medical diagnostic x-ray workers. Methods: The breakpoints of lymphocyte chromosomes are analyzed using G-banding. Results: There are 146 breakpoints among 3545 metaphase in 37 cases of X-ray workers. There are statistically significant differences between observed values and expected values (χ 2 =42.82, df=23, P 0.05). Conclusion: The chromosome aberration breakpoints of medical diagnostic X-ray workers are non-random. The observed values of breakpoint numbers are higher than those of the expected values in 7 and 14 chromosomes (P<0.05)

  16. CURRENT LEVELS OF MEDICAL EXPOSURE IN RUSSIA

    Directory of Open Access Journals (Sweden)

    M. I. Balonov

    2015-01-01

    Full Text Available We considered conditions of patients’ medical radiation exposure in Russian diagnostic radiology and nuclear medicine basing on the data of our own research, of the Unified system of individual dose control and of some relevant literature. We analyzed the data on the number of diagnostic examinations, patients’ individual and collective doses and their distribution by examination types. Time trends of the studied parameters are presented for the period between 1999 and 2013. Current level of Russian patients’ medical exposure is the lowest over the whole observation period and one of the lowest among the developed countries. The annual number of X-ray diagnostic examinations is 1.8 per capita. In 2013 median effective dose of medical exposure per capita in Russia was 0.45 mSv and median dose per procedure was 0.25 mSv. The major contribution to collective dose of medical exposure was from computed tomography and radiography; the largest individual doses were caused by interventional radiology, computed X-Ray and nuclear medicine tomographic examinations. The range of median doses comprises about four orders of magnitude, i.e. from several microSv in dental X-ray examinations up to several tens of milliSv in interventional and multistage tomographic examinations. The median effective dose of adult patients increases by about an order of magnitude with each transition from dental X-ray examinations to conventional radiology and further to computed tomography and interventional radiology examinations. During interventional X-Ray examinations, absorbed skin doses at radiation beam entrance site may reach several Gray, which may lead to deterministic radiation effects in skin and subcutaneous tissues. Due to replacement of low-dose ‘functional’ nuclear medicine examinations with more informative modern scintigraphy and tomography examination, patient doses substantially increased over the last decade. With current trend for re-equipment of

  17. A preface on advances in diagnostics for infectious and parasitic diseases: detecting parasites of medical and veterinary importance.

    Science.gov (United States)

    Stothard, J Russell; Adams, Emily

    2014-12-01

    There are many reasons why detection of parasites of medical and veterinary importance is vital and where novel diagnostic and surveillance tools are required. From a medical perspective alone, these originate from a desire for better clinical management and rational use of medications. Diagnosis can be at the individual-level, at close to patient settings in testing a clinical suspicion or at the community-level, perhaps in front of a computer screen, in classification of endemic areas and devising appropriate control interventions. Thus diagnostics for parasitic diseases has a broad remit as parasites are not only tied with their definitive hosts but also in some cases with their vectors/intermediate hosts. Application of current diagnostic tools and decision algorithms in sustaining control programmes, or in elimination settings, can be problematic and even ill-fitting. For example in resource-limited settings, are current diagnostic tools sufficiently robust for operational use at scale or are they confounded by on-the-ground realities; are the diagnostic algorithms underlying public health interventions always understood and well-received within communities which are targeted for control? Within this Special Issue (SI) covering a variety of diseases and diagnostic settings some answers are forthcoming. An important theme, however, throughout the SI is to acknowledge that cross-talk and continuous feedback between development and application of diagnostic tests is crucial if they are to be used effectively and appropriately.

  18. Diagnostic Machine Learning Models for Acute Abdominal Pain: Towards an e-Learning Tool for Medical Students.

    Science.gov (United States)

    Khumrin, Piyapong; Ryan, Anna; Judd, Terry; Verspoor, Karin

    2017-01-01

    Computer-aided learning systems (e-learning systems) can help medical students gain more experience with diagnostic reasoning and decision making. Within this context, providing feedback that matches students' needs (i.e. personalised feedback) is both critical and challenging. In this paper, we describe the development of a machine learning model to support medical students' diagnostic decisions. Machine learning models were trained on 208 clinical cases presenting with abdominal pain, to predict five diagnoses. We assessed which of these models are likely to be most effective for use in an e-learning tool that allows students to interact with a virtual patient. The broader goal is to utilise these models to generate personalised feedback based on the specific patient information requested by students and their active diagnostic hypotheses.

  19. Review of the regulation on the installation and use of X-ray equipment for medical diagnosis

    International Nuclear Information System (INIS)

    Alvarez Garcia, C.; Arguelles Sanchez, R.; Franco Artero, P.; Gil Gahete, M.; Rodriguez Marti, M.; Rueda Guerrero, M. D.; Villarroel Gonzalez-Eipe, R.

    2009-01-01

    The first regulation on the installation and use of X-ray equipment for the purposes of medical diagnosis was approved in 1991. This allowed the control of the safety of such equipment to be significantly improved. Royal Decree 1891/1991 has now been subjected to a review to update its contents and include the regulatory changes that have been incorporated in later standards, this having materialised with the Royal Decree 1085/2009, of July 3rd. (Author)

  20. Investments for medical equipment in a mother and child health hospital: correlation with level of services/departments.

    Science.gov (United States)

    Trevisanuto, Daniele; Raggi, Roberto; Bavuusuren, Bayasgalantai; Tudevdorj, Erkhembaatar; Doglioni, Nicoletta; Zanardo, Vincenzo

    2011-02-01

    To assess whether investments for medical equipments assigned by a team of experts to a mother and child health hospital located in Mongolia were correlated with structural, organizational, and educational level of its services/departments. A score was used for evaluating the level of each service/department. It was based on a 'structural area' and an 'organizational and educational area'. Destination of funds was determined by a team of experts in collaboration with the head of the service/department. Thirty-three of 36 services/departments (91.6%) were evaluated. A total sum of 4,432,140 Euros to invest in medical equipment was estimated. Assigned investments were inversely correlated with the total (structural plus organizational and educational area) score (n = 33; r =  -0.59; p = 0.0002), and the specific scores for structural area (n = 33; r = -0.46; p = 0.005) and organizational and educational area (n = 33; r =  -0.56; p = 0.0006). A large part of the funds for medical equipment was destined to services/departments with low organizational and educational conditions, limiting the potential effect of the aid meanwhile supporting the most in need departments. Educational efforts and monitoring of specific long-term indicators are mandatory.

  1. The future of novel diagnostics in medical mycology.

    Science.gov (United States)

    Teles, Fernando; Seixas, Jorge

    2015-04-01

    Several fungal diseases have become serious threats to human health and life, especially upon the advent of human immunodeficiency virus/AIDS epidemics and of other typical immunosuppressive conditions of modern life. Accordingly, the burden posed by these diseases and, concurrently, by intensive therapeutic regimens against these diseases has increased worldwide. Existing and available rapid tests for point-of-care diagnosis of important fungal diseases could enable the limitations of current laboratory methods for detection and identification of medically important fungi to be surpassed, both in low-income countries and for first-line diagnosis (screening) in richer countries. As with conventional diagnostic methods and devices, former immunodiagnostics have been challenged by molecular biology-based platforms, as a way to enhance the sensitivity and shorten the assay time, thus enabling early and more accurate diagnosis. Most of these tests have been developed in-house, without adequate validation and standardization. Another challenge has been the DNA extraction step, which is especially critical when dealing with fungi. In this paper, we have identified three major research trends in this field: (1) the application of newer biorecognition techniques, often applied in analytical chemistry; (2) the development of new materials with improved physico-chemical properties; and (3) novel bioanalytical platforms, allowing fully automated testing. Keeping up to date with the fast technological advances registered in this field, primarily at the proof-of-concept level, is essential for wise assessment of those that are likely to be more cost effective and, as already observed for bacterial and viral pathogens, may provide leverage to the current tepid developmental status of novel and improved diagnostics for medical mycology. © 2015 The Authors.

  2. Retrospective Dose Reconstruction for Medical Diagnostic X Ray Workers in China using Stable Chromosome Aberrations

    International Nuclear Information System (INIS)

    Wang, Q.; Liu, P.; Li, J.; Wang, Q.; Tang, S.; Sun, M.; Wang, L.; Aoyama, T.; Sugahara, T.

    1998-01-01

    The chromosome rearrangements in medical diagnostic X ray workers were analysed using the G-banding technique and evaluated collectively in accumulated doses. A total of 9102 metaphase spreads from 84 medical diagnostic X ray workers and 17 controls were scored. The results showed that: (1) the frequencies of translocation, stable chromosome aberration and total aberration in X ray workers were significantly higher than those of controls (P < 0.05 γ 0.005), unstable chromosome aberrations (including dicentric and acentric aberration) tended upwards; (2) the main aberration in stable aberrations was reciprocal translocation; (3) the stable aberration predominated strikingly in total aberrations. The medical diagnostic X ray workers were divided into three groups according to calendar year of entry. The data showed that the frequencies of translocation, stable aberration and total aberration increased with earlier year of entry, especially in two groups who started working before 1970. According to the equation recommended by Straume et al, linear coefficient (α) in the linear quadratic model provided by Fernandez's experiment, their collective accumulation doses calculated were 0.53, 0.26 and 0.06 Gy for calendar year of entry before 1960, 1960-1969, and after 1970, in X ray workers, respectively. (author)

  3. Children's exposure to diagnostic medical radiation and cancer risk: epidemiologic and dosimetric considerations

    Energy Technology Data Exchange (ETDEWEB)

    Linet, Martha S.; Rajaraman, Preetha [National Cancer Institute, Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, Bethesda, MD (United States); Kim, Kwang pyo [National Cancer Institute, Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, Bethesda, MD (United States); Kyung Hee University, Department of Nuclear Engineering, Yongin-si, Gyeonggi (Korea)

    2009-02-15

    While the etiology of most childhood cancers is largely unknown, epidemiologic studies have consistently found an association between exposure to medical radiation during pregnancy and risk of childhood cancer in offspring. The relation between early life diagnostic radiation exposure and occurrence of pediatric cancer risks is less clear. This review summarizes current and historical estimated doses for common diagnostic radiologic procedures as well as the epidemiologic literature on the role of maternal prenatal, children's postnatal and parental preconception diagnostic radiologic procedures on subsequent risk of childhood malignancies. Risk estimates are presented according to factors such as the year of birth of the child, trimester and medical indication for the procedure, and the number of films taken. The paper also discusses limitations of the methods employed in epidemiologic studies to assess pediatric cancer risks, the effects on clinical practice of the results reported from the epidemiologic studies, and clinical and public health policy implications of the findings. Gaps in understanding and additional research needs are identified. Important research priorities include nationwide surveys to estimate fetal and childhood radiation doses from common diagnostic procedures, and epidemiologic studies to quantify pediatric and lifetime cancer risks from prenatal and early childhood exposures to diagnostic radiography, CT, and fluoroscopically guided procedures. (orig.)

  4. Principles and applications of polymerase chain reaction in medical diagnostic fields: a review.

    Science.gov (United States)

    Valones, Marcela Agne Alves; Guimarães, Rafael Lima; Brandão, Lucas André Cavalcanti; de Souza, Paulo Roberto Eleutério; de Albuquerque Tavares Carvalho, Alessandra; Crovela, Sergio

    2009-01-01

    Recent developments in molecular methods have revolutionized the detection and characterization of microorganisms in a broad range of medical diagnostic fields, including virology, mycology, parasitology, microbiology and dentistry. Among these methods, Polymerase Chain Reaction (PCR) has generated great benefits and allowed scientific advancements. PCR is an excellent technique for the rapid detection of pathogens, including those difficult to culture. Along with conventional PCR techniques, Real-Time PCR has emerged as a technological innovation and is playing an ever-increasing role in clinical diagnostics and research laboratories. Due to its capacity to generate both qualitative and quantitative results, Real-Time PCR is considered a fast and accurate platform. The aim of the present literature review is to explore the clinical usefulness and potential of both conventional PCR and Real-Time PCR assays in diverse medical fields, addressing its main uses and advances.

  5. Structural shielding of medical X-ray rooms for diagnostic installations

    International Nuclear Information System (INIS)

    Rabitsch, H.

    1979-06-01

    In Part I (RIG 8), the various design procedures for shielding against X-rays are discussed and compared. In particular, this comparison is carried out between the shielding obtained conforming to the Austrian Regulations for Radiation Protection and that obtained from the DIN-standard DIN 6812; this latter includes the various operating conditions of diagnostic installations up to 150 kV. Several examples for particular structural shielding components in medical radiation rooms are given. (author)

  6. Clinical Training of Medical Physicists Specializing in Diagnostic Radiology (French Edition)

    International Nuclear Information System (INIS)

    2012-01-01

    The application of radiation in human health, for both diagnosis and treatment of disease, is an important component of the work of the IAEA. The responsibility for the increasing technical aspects of this work is undertaken by the medical physicist. To ensure good practice in this vital area, structured clinical training programmes are required to complement academic learning. This publication is intended to be a guide to the practical implementation of such a programme for diagnostic radiology. There is a general and growing awareness that radiation medicine is increasingly dependent on well trained medical physicists based in the clinical setting. However, an analysis of the availability of medical physicists indicates a large shortfall of qualified and capable professionals. This is particularly evident in developing countries. While strategies to increase academic educational opportunities are critical to such countries, the need for guidance on structured clinical training was recognized by the members of the Regional Cooperative Agreement (RCA) for Research, Development and Training related to Nuclear Sciences for Asia and the Pacific. Consequently, a technical cooperation regional project (RAS6038) under the RCA programme was formulated to address this need in the Asia-Pacific region by developing suitable material and establishing its viability. Development of a clinical training guide for medical physicists specializing in diagnostic radiology started in 2007 with the appointment of a core drafting committee of regional and international experts. The publication drew on the experiences of clinical training programmes in Australia and New Zealand, the UK and the USA, and was moderated by physicists working in the Asian region. This publication follows the approach of the IAEA publication Training Course Series No. 37, Clinical Training of Medical Physicists specializing in Radiation Oncology. This approach to clinical training has been successfully tested

  7. Clinical Training of Medical Physicists Specializing in Diagnostic Radiology (Spanish Edition)

    International Nuclear Information System (INIS)

    2013-01-01

    The application of radiation in human health, for both diagnosis and treatment of disease, is an important component of the work of the IAEA. The responsibility for the increasing technical aspects of this work is undertaken by the medical physicist. To ensure good practice in this vital area, structured clinical training programmes are required to complement academic learning. This publication is intended to be a guide to the practical implementation of such a programme for diagnostic radiology. There is a general and growing awareness that radiation medicine is increasingly dependent on well trained medical physicists based in the clinical setting. However, an analysis of the availability of medical physicists indicates a large shortfall of qualified and capable professionals. This is particularly evident in developing countries. While strategies to increase academic educational opportunities are critical to such countries, the need for guidance on structured clinical training was recognized by the members of the Regional Cooperative Agreement (RCA) for Research, Development and Training related to Nuclear Sciences for Asia and the Pacific. Consequently, a technical cooperation regional project (RAS6038) under the RCA programme was formulated to address this need in the Asia-Pacific region by developing suitable material and establishing its viability. Development of a clinical training guide for medical physicists specializing in diagnostic radiology started in 2007 with the appointment of a core drafting committee of regional and international experts. The publication drew on the experiences of clinical training programmes in Australia and New Zealand, the UK and the USA, and was moderated by physicists working in the Asian region. This publication follows the approach of the IAEA publication Training Course Series No. 37, Clinical Training of Medical Physicists specializing in Radiation Oncology. This approach to clinical training has been successfully tested

  8. Guidance notes for the protection of persons against ionising radiations arising from medical and dental use

    International Nuclear Information System (INIS)

    1988-01-01

    Guidance notes have been prepared by the NRPB, the Health Departments and the Health and Safety Executive for the protection of all persons against ionising radiations arising from medical and dental use. The guidance notes are a guide to good radiation protection practice consistent with regulatory requirements. The areas covered include medical and dental radiology, diagnostic X-ray equipment for medical and dental radiography, beam therapy and remotely controlled after-loading, brachytherapy, diagnostic and therapeutic uses of unsealed radioactive substances, diagnostic uses of sealed or other solid radioactive sources, patients leaving hospital after administration of radioactive substances, precautions after death of a patient whom radioactive substances have been administered, storage and movement of radioactive substances, disposal of radioactive waste and contingency planning and emergency procedures. (U.K.)

  9. Value of multi-criteria decision analysis in early assessment of medical diagnostic devices

    NARCIS (Netherlands)

    IJzerman, Maarten Joost; Hummel, J. Marjan

    2010-01-01

    OBJECTIVES: Multicriteria decision analytic (MCDA) techniques are a powerful tool in evaluating health care interventions where multiple, often competing, factors need to be considered. The analytic hierarchy process (AHP) is one such technique. We have applied AHP to evaluate medical diagnostic

  10. Cancer risk analysis among medical diagnostic X-ray workers in China

    International Nuclear Information System (INIS)

    Wang Jixian; Li Benxiao; Gao Zhiwei; Xu Jun; Zhang Jingyuan; Aoyama, Takashi; Sugahara, Tsutomu

    1997-01-01

    To provide the evidence and related rules of human malignant tumors produced by prolonged exposure to low level ionizing radiation. The cancer incidence (1950-1990) among 27011 medical diagnostic X-ray workers was compared with that among 25782 other medical specialists employed between 1950 and 1980 in China by means of O/E system. A significantly elevated risk of cancer was seen among diagnostic x-ray workers (RR = 1.1,95%Cl:1.0-1.2,P <0.05). Significantly elevated risks were seen for leukemia and cancers of skin, female breast, liver and esophagus, the RR being 2.3, 5.0, 1.6, 1.3 and 4.4 respectively. The RR for leukemia was higher for X-ray workers who began employment before 1970 and also for those who were young when employment began. The patterns of risk associated with length of service and with age and calendar year of initial employment suggest that the excesses of leukemia, skin cancer and female breast cancer were due to occupational exposure to X-rays. The ERR and EAR for leukemia and solid cancer were calculated roughly. (author)

  11. Traps in quality assurance of diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Meier, N.; Lenzen, H.; Fiebich, M.

    1992-01-01

    With the introduction of the German industrial protocol for quality assurance of X-ray equipment, everybody using X-ray machines fell into sort of trap or found some of the procedures misleading. Vigorous discussions were held on every conceivable aspect of this and other protocols, and are still in progress. This paper points out some of the common traps and considers a new type dosimeter, which allows a definite separation of quality assurance of X-ray equipment and of processing and which can also be used in future for quality assurance of digital radiography equipment. (orig.) [de

  12. [The challenges of standardization in clinical diagnostic laboratories of medical organizations].

    Science.gov (United States)

    Men'shikov, V V

    2013-04-01

    The generalized data concerning the conditions of application of regulations of national standards in clinical diagnostic laboratories of medical organizations is presented. The primary information was provided by 14 regions of 6 federal administrative okrugs of Russia. The causes of challenges of application of requirements of standards are presented. They are mostly related with insufficient financial support, lacking of manpower, difficulties with reagents supply, inadequate technical maintenance of devices and absence of support of administration of medical organizations. The recommendations are formulated concerning the necessity of publishing the document of Minzdrav of Russia to determine the need in application of standards in laboratory practice.

  13. CSIR research, development and innovation initiatives for the medical device and diagnostic industry

    CSIR Research Space (South Africa)

    Vilakazi, Busisiwe

    2017-10-01

    Full Text Available This presentation is focused on development and innovation initiatives in the medical device and diagnostic industry. It is presented by Dr Busisiwe Vilakasi at The 6th CSIR Conference: Ideas that work for industrial development, 5-6 October 2017...

  14. Diagnostic Imaging in the Medical Support of the Future Missions to the Moon

    Science.gov (United States)

    Sargsyan, Ashot E.; Jones, Jeffrey A.; Hamilton, Douglas R.; Dulchavsky, Scott A.; Duncan, J. Michael

    2007-01-01

    This viewgraph presentation is a course that reviews the diagnostic imaging techniques available for medical support on the future moon missions. The educational objectives of the course are to: 1) Update the audience on the curreultrasound imaging in space flight; 2) Discuss the unique aspects of conducting ultrasound imaging on ISS, interplanetary transit, ultrasound imaging on ISS, interplanetary transit, and lunar surface operations; and 3) Review preliminary data obtained in simulations of medical imaging in lunar surface operations.

  15. Russian medical X-ray engineering is confidently going into the year 2000

    International Nuclear Information System (INIS)

    Chikirdin, Eh.G.

    2000-01-01

    The achievements of the national medical X-ray technique are analyzed on the basis of the materials of the International exhibition Public health-99 which took place in November-December 1999, are analyzed. Great attention of the enterprises-developers was paid to fluorographic-digital equipment due to actuality of the lungs tuberculosis control in Russia. The characteristics for several fluorographic digital facilities, wherein by high technical characteristics it proves possible to improve the design and obtain low radiation doses for the patients and sufficiently low cost of the equipment, are presented. The characteristics of mobile facilities for X-ray diagnostics, including a fluorograph, mammograph, dental X-ray apparatus, are also presented. The attention was also paid to a X-ray diagnostic complex, feed devices, phantom sets, tomograph, dental apparatus and other developments in the area of X-ray technique. The outlooks for developments in the area of the national medical Xray technique are noted [ru

  16. Procuring, maintaining and using equipment: the key issues in controlling exposure to patients

    International Nuclear Information System (INIS)

    Hendra, I.R.F.

    1989-01-01

    Radiological equipment is not purpose-built for each individual application. Thus, not only are acceptance criteria directly related to the design of equipment and the quality assurance exercised during its manufacture, but also the performance, safety and reliability of equipment must feature in the requirements for procuring new equipment. In the UK this issue is dealt with under the Department of Health and Social Security Manufacturer Registration Scheme for Medical Equipment in its application to radiological equipment. Similarly the continuing reliability of equipment in service is directly related to the quality of maintenance services. This is determined largely by the manner in which such services are procured. In the UK this issue has been considered by one of four Working Parties commissioned by the South-East Thames Regional Health Authority who are the ''Centre of Responsibility'' for diagnostic imaging equipment. The report prepared from the first phase of activity of this working group describes features of a procurement specification for maintenance services and prescribes the complementary duties of contractors and customers. The use in X-ray departments of the kind of manufacturing quality system that is used by most reputable equipment manufacturers has the potential for a dramatic reduction in exposure to patients. (author)

  17. FY 2000 Report on the survey results. Survey on international cooperation for medical treatment/welfare equipment; 2000 nendo iryo fukushi kiki kokusai kyodo kenkyu jigyo chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    The NEDO's representatives visited Europe and China with the objectives of, e.g., international cooperation and information exchanges for medical treatment/welfare equipment. For the welfare equipment technologies, they visited the research institutes and facilities in UK and Germany, among others, to find that the European countries place more emphasis on researches to meet the needs than on advancing the equipment itself. For the medical treatment equipment, they visited the bio-research institutes in Europe for exchanging information on post-genome and tissue engineering. The European countries are behind USA in research fund and manpower for bio-technology and bio-medical, although making great efforts with much expectation on these areas. The China's medical treatment/welfare technologies seem to be clearly still in the stage of needing aids rather than rendering cooperation. However, China has been producing a number of new products in the areas where her traditional arts of medicine are combined with advanced techniques of the West, e.g., those for examination, as felt from a number of the equipment types presented to the China Medical Treatment Equipment Exhibition. (NEDO)

  18. Photoionization sensors for non-invasive medical diagnostics

    Science.gov (United States)

    Mustafaev, Aleksandr; Rastvorova, Iuliia; Khobnya, Kristina; Podenko, Sofia

    2016-09-01

    The analysis of biomarkers can help to identify the significant number of diseases: lung cancer, tuberculosis, diabetes, high levels of stress, psychosomatic disorders etc. To implement continuous monitoring of the state of human health, compact VUV photoionization detector with current-voltage measurement is designed by Saint-Petersburg Mining University Plasma Research Group. This sensor is based on the patented method of stabilization of electric parameters - CES (Collisional Electron Spectroscopy). During the operation at atmospheric pressure VUV photoionization sensor measures the energy of electrons, produced in the ionization with the resonance photons, whose wavelength situated in the vacuum ultraviolet (VUV). A special software was developed to obtain the second-order derivative of the I-U characteristics, taken by the VUV sensor, to construct the energy spectra of the characteristic electrons. VUV photoionization detector has an unique set of parameters: small size (10*10*1 mm), low cost, wide range of recognizable molecules, as well as accuracy, sufficient for using this instrument for the medical purposes. This device can be used for non-invasive medical diagnostics without compromising the quality of life, for control of environment and human life. Work supported by Foundation for Assistance to Small Innovative Enterprises in Science and Technology.

  19. Human-centered design of the human-system interfaces of medical equipment: thyroid uptake system

    International Nuclear Information System (INIS)

    Monteiro, Jonathan K.R.; Farias, Marcos S.; Santos, Isaac J.A. Luquetti; Monteiro, Beany G.

    2013-01-01

    Technology plays an important role in modern medical centers, making healthcare increasingly complex, relying on complex technical equipment. This technical complexity is particularly noticeable in the nuclear medicine. Poorly design human-system interfaces can increase the risks for human error. The human-centered approach emphasizes the development of the equipment with a deep understanding of the users activities, current work practices, needs and abilities of the users. An important concept of human-centered design is that the ease-of-use of the equipment can be ensured only if users are actively incorporated in all phases of the life cycle of design process. Representative groups of users are exposed to the equipment at various stages in development, in a variety of testing, evaluation and interviewing situations. The users feedback obtained is then used to refine the design, with the result serving as input to the next interaction of design process. The limits of the approach are that the users cannot address any particular future needs without prior experience or knowledge about the equipment operation. The aim of this paper is to present a methodological framework that contributes to the design of the human-system interfaces, through an approach related to the users and their activities. A case study is described in which the methodological framework is being applied in development of new human-system interfaces of the thyroid uptake system. (author)

  20. 75 FR 26196 - Publication of OIG Updated Special Fraud Alert on Telemarketing by Durable Medical Equipment...

    Science.gov (United States)

    2010-05-11

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Office of Inspector General Publication of OIG Updated Special Fraud Alert on Telemarketing by Durable Medical Equipment Suppliers AGENCY: Office of Inspector...) 205-0007. SUPPLEMENTARY INFORMATION: In our publication of the OIG Updated Special Fraud Alert on...

  1. Medical thoracoscopy: a useful diagnostic tool for undiagnosed pleural effusion.

    Science.gov (United States)

    Agarwal, Abhishek; Prasad, Rajendra; Garg, Rajiv; Verma, S K; Singh, Abhijeet; Husain, N

    2014-01-01

    We aimed to assess the role of medical thoracoscopy in patients with undiagnosed pleural effusion. Patiens presenting with pleural effusion underwent three pleural aspirations. Patients in whom pleural fluid analysis was inconclusive underwent closed pleural biopsy for diagnostic confirmation. Patients in whom closed pleural biopsy was incolcusive underwent medical thoracoscopy using a rigid thoracoscope with a viewing angle of zero degrees was done under local anaesthesia and sedation with the patient lying in lateral decubitus position with the affected side up. Biopsy specimens from parietal pleura were obtained under direct vision and were sent for histopathological examination. Of the 128 patients with pleural effusion who were studied, pleural fluid examination established the diagnosis in 81 (malignancy 33, tuberculosis 33, pyogenic 14 and fungal 1); 47 patients underwent closed pleural biopsy and a diagnosis was made in 28 patients (malignancy 24, tuberculosis 4). The remaining 19 patients underwent medical thoracoscopy and pleural biopsy and the aetiological diagnosis could be confirmed in 13 of the 19 patients (69%) (adenocarcinoma 10, poorly differentiated carcinoma 2 and mesothelioma 1). Medical thoracoscopy is a useful tool for the diagnosis of pleural diseases. The procedure is safe with minimal complications.

  2. 21 CFR 866.4540 - Immunonephelometer equipment.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents § 866.4540 Immunonephelometer equipment. (a) Identification. Immunonephelometer equipment for clinical use...

  3. 21 CFR 866.4520 - Immunofluorometer equipment.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents § 866.4520 Immunofluorometer equipment. (a) Identification. Immunofluorometer equipment for clinical use with...

  4. Radiographic techniques adaptation for any conventional X-ray equipment

    International Nuclear Information System (INIS)

    Pina, Diana R.; Ghilardi Netto, Thomaz; Martinez, Alexandre S.; Duarte, Sergio B.; Trad, Clovis S.; Brochi, Marco Aurelio C.

    2001-01-01

    In order to obtain a better risk-benefice relation in diagnostic radiology it turns out to be essential the control and optimization of the radiographic techniques used to reduce the absorbed doses until its minimum, keeping or adjusting the diagnostic image at any X-ray equipment. The present work deals with the standardization of radiographic techniques of chest, skull and pelvis, which is more suitable for obtaining a safe diagnostic with smaller doses, for a standard patient, at any conventional X-ray equipment. (author)

  5. Diagnostic radiology physics: A handbook for teachers and students. Endorsed by: American Association of Physicists in Medicine, Asia-Oceania Federation of Organizations for Medical Physics, European Federation of Organisations for Medical Physics

    Energy Technology Data Exchange (ETDEWEB)

    Dance, D. R. [Royal Surrey County Hospital, Guildford (United Kingdom); Christofides, S. [New Nicosia General Hospital (Cyprus); Maidment, A. D.A. [University of Pennsylvania (United States); McLean, I. D. [International Atomic Energy Agency, Vienna (Austria); Ng, K. H. [University of Malaya, Kuala Lumpur (Malaysia)

    2014-09-15

    This publication is written for students and teachers involved in programmes that train medical physicists for work in diagnostic radiology. It provides, in the form of a syllabus, a comprehensive overview of the basic medical physics knowledge required for the practice of modern diagnostic radiology. This makes it particularly useful for graduate students and residents in medical physics programmes. The material presented in the publication has been endorsed by the major international organizations and is the foundation for academic and clinical courses in both diagnostic radiology physics and in emerging areas such as imaging in radiotherapy.

  6. Quality control in diagnostic radiology. Historical development and present status in Europe

    International Nuclear Information System (INIS)

    Michael Moores, B.

    2007-01-01

    Complete test of publication follows. Quality control is now an accepted activity within the overall radiation protection framework for diagnostic radiology. Indeed it is now a legal requirement within Member States specified in EC Directives that establish the basic requirements for radiation protection in medicine. This was not always the case and its historical development can be considered in three parts: 1) The development of test procedures and standardisation of practices; 2) Harmonisation of initiatives and the creation of a European dimension in such practices; 3) Its role and function in a changing and evolving technological environment - current status and future needs. The development of tests methods for diagnostic X-ray equipment was initially intimately related to the development of a scientific basis for the X-ray imaging process. Knowledge of the physical basis for image production in film-screen and fluoroscopic processes required the definition and specification and measurement of particular parameters within the image forming chain. The development of test methods and the necessary measuring equipment involved ongoing research and development by physical scientists throughout Europe and North America. However, the many different approaches employed meant that results of measurements could not always be compared. However, once acceptable test methods and equipment had been developed it was possible to standardise practices through the development of test protocols. In 1980 a foundation for collective European actions was established through the EC radiation protection research and development programme. This helped to establish a European wide forum for actions in the field of medical radiation protection including quality control. These initiatives were driven by EC Directives, which were concerned with protection of the worker, general public and patients from medical practices that utilised ionising radiation. Multi national research

  7. TH-F-209-01: Pitfalls: Reliability and Performance of Diagnostic X-Ray Sources

    International Nuclear Information System (INIS)

    Behling, R.

    2016-01-01

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. Learning Objectives: Understand the basic requirements on medical diagnostic X-ray sources per modality Learn to select the optimal equipment employing state-of-the-art metric Know causes of failures, depending on the way X-ray sources are operated Understand methods to remediate

  8. TH-F-209-00: Pitfalls: Reliability and Performance of Diagnostic X-Ray Sources

    International Nuclear Information System (INIS)

    2016-01-01

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. Learning Objectives: Understand the basic requirements on medical diagnostic X-ray sources per modality Learn to select the optimal equipment employing state-of-the-art metric Know causes of failures, depending on the way X-ray sources are operated Understand methods to remediate

  9. TH-F-209-01: Pitfalls: Reliability and Performance of Diagnostic X-Ray Sources

    Energy Technology Data Exchange (ETDEWEB)

    Behling, R. [Philips Medical Systems DMC GmbH (United States)

    2016-06-15

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. Learning Objectives: Understand the basic requirements on medical diagnostic X-ray sources per modality Learn to select the optimal equipment employing state-of-the-art metric Know causes of failures, depending on the way X-ray sources are operated Understand methods to remediate

  10. TH-F-209-00: Pitfalls: Reliability and Performance of Diagnostic X-Ray Sources

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. Learning Objectives: Understand the basic requirements on medical diagnostic X-ray sources per modality Learn to select the optimal equipment employing state-of-the-art metric Know causes of failures, depending on the way X-ray sources are operated Understand methods to remediate

  11. Design and Implementation of a Portal for the Medical Equipment Market: MEDICOM

    Science.gov (United States)

    Kalivas, Dimitris; Panou-Diamandi, Ourania; Zeelenberg, Cees; van Nimwegen, Chris

    2001-01-01

    Background The MEDICOM (Medical Products Electronic Commerce) Portal provides the electronic means for medical-equipment manufacturers to communicate online with their customers while supporting the Purchasing Process and Post Market Surveillance. The Portal offers a powerful Internet-based search tool for finding medical products and manufacturers. Its main advantage is the fast, reliable and up-to-date retrieval of information while eliminating all unrelated content that a general-purpose search engine would retrieve. The Universal Medical Device Nomenclature System (UMDNS) registers all products. The Portal accepts end-user requests and generates a list of results containing text descriptions of devices, UMDNS attribute values, and links to manufacturer Web pages and online catalogues for access to more-detailed information. Device short descriptions are provided by the corresponding manufacturer. The Portal offers technical support for integration of the manufacturers' Web sites with itself. The network of the Portal and the connected manufacturers' sites is called the MEDICOM system. Objective To establish an environment hosting all the interactions of consumers (health care organizations and professionals) and providers (manufacturers, distributors, and resellers of medical devices). Methods The Portal provides the end-user interface, implements system management, and supports database compatibility. The Portal hosts information about the whole MEDICOM system (Common Database) and summarized descriptions of medical devices (Short Description Database); the manufacturers' servers present extended descriptions. The Portal provides end-user profiling and registration, an efficient product-searching mechanism, bulletin boards, links to on-line libraries and standards, on-line information for the MEDICOM system, and special messages or advertisements from manufacturers. Platform independence and interoperability characterize the system design. Relational Database

  12. Design and implementation of a portal for the medical equipment market: MEDICOM.

    Science.gov (United States)

    Palamas, S; Kalivas, D; Panou-Diamandi, O; Zeelenberg, C; van Nimwegen, C

    2001-01-01

    The MEDICOM (Medical Products Electronic Commerce) Portal provides the electronic means for medical-equipment manufacturers to communicate online with their customers while supporting the Purchasing Process and Post Market Surveillance. The Portal offers a powerful Internet-based search tool for finding medical products and manufacturers. Its main advantage is the fast, reliable and up-to-date retrieval of information while eliminating all unrelated content that a general-purpose search engine would retrieve. The Universal Medical Device Nomenclature System (UMDNS) registers all products. The Portal accepts end-user requests and generates a list of results containing text descriptions of devices, UMDNS attribute values, and links to manufacturer Web pages and online catalogues for access to more-detailed information. Device short descriptions are provided by the corresponding manufacturer. The Portal offers technical support for integration of the manufacturers Web sites with itself. The network of the Portal and the connected manufacturers sites is called the MEDICOM system. To establish an environment hosting all the interactions of consumers (health care organizations and professionals) and providers (manufacturers, distributors, and resellers of medical devices). The Portal provides the end-user interface, implements system management, and supports database compatibility. The Portal hosts information about the whole MEDICOM system (Common Database) and summarized descriptions of medical devices (Short Description Database); the manufacturers servers present extended descriptions. The Portal provides end-user profiling and registration, an efficient product-searching mechanism, bulletin boards, links to on-line libraries and standards, on-line information for the MEDICOM system, and special messages or advertisements from manufacturers. Platform independence and interoperability characterize the system design. Relational Database Management Systems are used for

  13. Update of diagnostic medical and dental x-ray exposures in Romania

    Energy Technology Data Exchange (ETDEWEB)

    Sorop, Ioana; Mossang, Daniela; Dadulescu, Elena [Radiation Hygiene Laboratory of Public Health Authority Dolj, 2, Constantin Lecca Street, Craiova (Romania); Iacob, Mihai Radu [University ' Alexandru Ioan Cuza' , 11, Carol I Street, 700506, Iasi (Romania); Iacob, Olga [Institute of Public Health, 14, Victor Babes Street, 700465 Iasi (Romania)], E-mail: danamossang@sanpubdj.ro

    2008-12-15

    This national study, the third in the last 15 years, updates the magnitude of medical radiation exposure from conventional x-ray examinations, in order to optimise the radiological protection to the population in a cost-effective manner. Effective doses from diagnostic radiology were estimated for adult and paediatric patients undergoing the 20 most important types of x-ray examination. Data were collected from 179 x-ray departments, selected by their annual workload, throughout the country. Estimates were made using two dosimetric quantities: entrance surface dose, derived from the absorbed dose in air measured by simulation of radiographic examinations, and dose-area product, measured during fluoroscopic examinations performed on adult and paediatric patients. Conversion coefficients to effective dose of the UK National Radiological Protection Board (NRPB) have been used in all calculations. The effective dose per patient from all medical x-ray examinations was 0.74 mSv and the resulting annual collective effective dose was 6930 man Sv, with annual effective dose per caput of 0.33 mSv. The current size of population exposure from diagnostic radiology is lower than the previous one by 40%, but could be about 30% higher by taking into account the estimated contribution from computed tomography (CT) procedures.

  14. MO-AB-210-00: Diagnostic Ultrasound Imaging Quality Control and High Intensity Focused Ultrasound Therapy Hands-On Workshop

    International Nuclear Information System (INIS)

    2015-01-01

    The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS

  15. MO-AB-210-00: Diagnostic Ultrasound Imaging Quality Control and High Intensity Focused Ultrasound Therapy Hands-On Workshop

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-06-15

    The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS

  16. DXplain: a Web-based diagnostic decision support system for medical students.

    Science.gov (United States)

    London, S

    1998-01-01

    DXplain is a diagnostic decision support program, with a new World Wide Web interface, designed to help medical students and physicians formulate differential diagnoses based on clinical findings. It covers over 2000 diseases and 5000 clinical manifestations. DXplain suggests possible diagnoses, and provides brief descriptions of every disease in the database. Not all diseases are included, nor does DXplain take into account preexisting conditions or the chronological sequence of clinical manifestations. Despite these limitations, it is a useful educational tool, particularly for problem-based learning (PBL) cases and for students in clinical rotations, as it fills a niche not adequately covered by MEDLINE or medical texts. The system is relatively self-explanatory, requiring little or no end-user training. Medical libraries offering, or planning to offer, their users access to Web-based materials and resources may find this system a valuable addition to their electronic collections. Should it prove popular with the local users, provision of access may also establish or enhance the library's image as a partner in medical education.

  17. Biomedical visual data analysis to build an intelligent diagnostic decision support system in medical genetics.

    Science.gov (United States)

    Kuru, Kaya; Niranjan, Mahesan; Tunca, Yusuf; Osvank, Erhan; Azim, Tayyaba

    2014-10-01

    In general, medical geneticists aim to pre-diagnose underlying syndromes based on facial features before performing cytological or molecular analyses where a genotype-phenotype interrelation is possible. However, determining correct genotype-phenotype interrelationships among many syndromes is tedious and labor-intensive, especially for extremely rare syndromes. Thus, a computer-aided system for pre-diagnosis can facilitate effective and efficient decision support, particularly when few similar cases are available, or in remote rural districts where diagnostic knowledge of syndromes is not readily available. The proposed methodology, visual diagnostic decision support system (visual diagnostic DSS), employs machine learning (ML) algorithms and digital image processing techniques in a hybrid approach for automated diagnosis in medical genetics. This approach uses facial features in reference images of disorders to identify visual genotype-phenotype interrelationships. Our statistical method describes facial image data as principal component features and diagnoses syndromes using these features. The proposed system was trained using a real dataset of previously published face images of subjects with syndromes, which provided accurate diagnostic information. The method was tested using a leave-one-out cross-validation scheme with 15 different syndromes, each of comprised 5-9 cases, i.e., 92 cases in total. An accuracy rate of 83% was achieved using this automated diagnosis technique, which was statistically significant (pbenefits of using hybrid image processing and ML-based computer-aided diagnostics for identifying facial phenotypes. Copyright © 2014. Published by Elsevier B.V.

  18. Development of the testing procedure for units and elements of mining equipment

    Directory of Open Access Journals (Sweden)

    P. B. Gerike

    2017-09-01

    Full Text Available The author considers in detail the stages of creating a testing procedure for mining equipment based on the complex implementation of principles of nondestructive testing and technical diagnostics. The author substantiates effectiveness of application of a complex diagnostic approach for assessing the state of metal structures and energy-mechanical equipment of mining machines. The opportunity for timely detection of defects, regardless of their type and degree of danger, presents itself only with a wide application of the modern methods of vibration diagnostics and nondestructive testing. The author substantiates the effectiveness of specific combination of methods of nondestructive testing, most optimally suited for solving given tasks. The article contains the developed complex of more than 120 diagnostic rules, suitable for performing automated analysis of vibroacoustic signal and revealing the main damages of energy-mechanical equipment based on selective groups of informative frequencies. The author formulates the main criteria that one can use as a basic platform for improving the methodology for normalizing the parameters of mechanical oscillations. The developed diagnostic criteria became a basis for the development of individual spectral masks suitable for performing the analysis of parameters of vibroacoustic waves generated during operation of mining equipment. The author proves necessity of transition of repair and maintenance divisions of industrial enterprises to the system of maintenance of machinery according to its actual technical state, and the developed complex of diagnostic rules for detecting defects can serve as a platform for the implementation of basic elements of this system. The author substantiates the principal validity of the developed methodology for testing mining machines equipment and its individual elements, such as the predictive modeling of degradation of technical state of mining equipment and the

  19. Specification for high voltage cable plug and socket connections for medical X-ray equipment

    International Nuclear Information System (INIS)

    1980-01-01

    Under the direction of the Light Engineering Standards Committee, a British Standard Specification has been prepared for three-conductor and four-conductor high-voltage cable plug and socket connections for medical X-ray equipment. The standard deals with the essential dimensions to ensure mechanical interchangeability, the recommended dimensions, the wiring connections to contacts of plug and socket and the marking of contacts of plug and socket. (U.K.)

  20. Senior medical students' awareness of radiation risks from common diagnostic imaging examinations.

    Science.gov (United States)

    Scali, Elena; Mayo, John; Nicolaou, Savvas; Kozoriz, Michael; Chang, Silvia

    2017-12-01

    Senior medical students represent future physicians who commonly refer patients for diagnostic imaging studies that may involve ionizing radiation. The radiology curriculum at the University of British Columbia provides students with broad-based knowledge about common imaging examinations. The purpose of this study was to investigate students' awareness of radiation exposures and risks. An anonymous multiple-choice cross-sectional questionnaire was distributed to final year medical students to assess knowledge of radiation from common diagnostic examinations and radiation-related risks following completion of the longitudinal radiology curriculum, carried out over the four years of medical training. Sixty-three of 192 eligible students participated (33% response rate). The majority felt that knowledge of radiation doses of common imaging examinations is somewhat or very important; however, only 12% (N = 8) routinely discuss radiation-related risks with patients. While all respondents recognized children as most sensitive to the effects of radiation, only 24% (N = 15) correctly identified gonads as the most radiation-sensitive tissue. Almost all respondents recognized ultrasound and MRI as radiation free modalities. Respondents who correctly identified the relative dose of common imaging examinations in chest x-ray equivalents varied from 3-77% (N = 2 - 49); the remaining responses were largely underestimates. Finally, 44% (N = 28) correctly identified the excess risk of a fatal cancer from an abdominal CT in an adult, while the remainder underestimated this risk. Medical students acknowledge the importance of radiation-related issues to patient care. While almost all students are familiar with radiation-free modalities, many are not familiar with, and commonly underestimate, the relative doses and risks of common imaging studies. This may expose patients to increasing imaging investigations and exposure to radiation hazards.

  1. Stochastic risk estimation from medical x-ray diagnostic examinations, 2

    International Nuclear Information System (INIS)

    Hashizume, Tadashi; Maruyama, Takashi; Noda, Yutaka; Iwai, Kazuo; Tateno, Y.; Nishizawa, Kanae.

    1981-01-01

    The risks of genetic, leukemia and malignant diseases from medical X-ray diagnostic examinations were estimated using the frequency of radiographic and fluoroscopic exposures per diagnostic examination, child expectancy, leukemia and malignancy significant factors, and using a weighting factor determined on the basis of data concerning the cancer mortality among atomic bomb survivors in Nagasaki and of a recommendation of International Commission of Radiological Protection. The organ or tissue doses with respect to the stochastic risks were determined with ionization chambers and thermoluminescent dosimeters placed at the positions of the organs or tissues in a RANDO woman phantom which was exposed to diagnostic X-rays according to technical factors of typical radiographic and fluoroscopic examinations obtained from a nationwide survey. The resultant risks by age-group and type of radiographic and fluoroscopic examination are tabulated in terms of risk level of 10 -6 . In general, the total risk defined as the sum of genetic, leukemia and malignant risks was a high value for the X-ray diagnosis of digestive organs involving barium meal and barium enema. For example, the total risk for young age-group was 100 to 200 x 10 -6 for the X-ray diagnosis of digestive organs. The total risk from the chest radiography was lower value as compared with the risk from the X-ray diagnosis of other organs or tissues. On the contrary, the risk from the chest tomography was comparable to the risk from the diagnosis of digestive organs. The total risk decreased with increasing of age for every X-ray diagnostic examination. (author)

  2. Medical equipment archives management based on internet%基于互联网的医疗器械档案管理

    Institute of Scientific and Technical Information of China (English)

    杨琼

    2017-01-01

    目的:有效管理医疗器械档案,实现档案信息资源的共享.方法:通过互联网管理平台与内网相结合的多途径、多渠道管理模式,根据医疗设备和医用耗材档案管理的不同需求进行分类管理.结果:销售公司作为用户参与到医院管理工作中来,充分发挥了他们的主观能动性,有效减轻了设备科的工作压力;工作人员可以随时随地登录网站查阅、录入信息,为工作提供方便,实现了医疗器械电子档案精确动态管理.结论:医疗器械档案管理网络化是档案收集及充分发挥档案作用的一个有效途径.%Objective To effectively manage the archives of medical equipment and realize the sharing of archives information resources.Methods Multi-way management mode integrating internet management platform and intranet was involved in classification management according to the requirements of medical equipment and consumables archives management.Results Distribution company was involved in hospital management as the user,and the workload of the equipment department was relieved effectively.The staff could inquire and input information by logging in the website,and precision and dynamic management of medical equipment electronic archives was realized.Conclusion Network-based medical equipment archives management contributes to the collection and application of the archives.

  3. Transmission of hazardous diseases via nanobacterial contamination of medical and dental equipment

    Directory of Open Access Journals (Sweden)

    Jafar Kolahi

    2013-01-01

    Full Text Available Introduction: Nanobacteria (calcifying nanoparticles, nanobes are one of the most controversial issues in contemporary biology. Studies show accumulating evidence on association of nanobacteria with pathologic calcifications such as kidney stone, arterial plaque, calcification of coronary arteries, and cardiac valves calculus. The Hypothesis: Nanobacteria can tolerate harsh conditions extremely well. The apatite mineral layer around the organism and slow metabolism is likely to be the reason for the resistance of nanobacteria. They showed a wide resistance to the several disinfecting and sterilizating chemicals as well as autoclaving, ultraviolet light, microwaves, heating and drying treatments. Hence, it seems logic to postulate that hazardous diseases can be easily transmitted via nanobacterial contamination of medical and dental equipment. Evaluation of the Hypothesis: It is not enough to claim an agent not living according to the standard view on living creatures, as irrelevant to biological safety of cell cultures, or to human and animal health. Although the nature of prions is still under debate and prions are classified as nonliving, they exist and cause diseases, and thus form a serious risk for animal and human health. The risk was recognized only after enormous economical losses. It appears that nanobacteria situation is rather similar, except the fact that nanobacteria appear to cause or contribute to common hazardous diseases of the mankind. Hence, world-widely well-known organizations such as the Centers for Disease Control and Prevention, the Occupational Safety and Health Administration, and the World Health Organization should pay more attention to transmission of hazardous diseases via nanobacterial contamination of medical and dental equipment.

  4. Are diagnostic criteria for eating disorders markers of medical severity?

    Science.gov (United States)

    Peebles, Rebecka; Hardy, Kristina K; Wilson, Jenny L; Lock, James D

    2010-05-01

    The objective of this study was to compare the medical severity of adolescents who had eating disorders not otherwise specified (EDNOS) with those who had anorexia nervosa (AN) and bulimia nervosa (BN). Medical records of 1310 females aged 8 through 19 years and treated for AN, BN, or EDNOS were retrospectively reviewed. Patients with EDNOS were subcategorized into partial AN (pAN) and partial BN (pBN) when they met all Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition criteria but 1 for AN or BN, respectively. Primary outcome variables were heart rate, systolic blood pressure, temperature, and QTc interval on electrocardiogram. Additional physiologically significant medical complications were also reviewed. A total of 25.2% of females had AN, 12.4% had BN, and 62.4% had EDNOS. The medical severity of patients with EDNOS was intermediate to that of patients with AN and BN in all primary outcomes. Patients with pAN had significantly higher heart rates, systolic blood pressures, and temperatures than those with AN; patients with pBN did not differ significantly from those with BN in any primary outcome variable; however, patients with pAN and pBN differed significantly from each other in all outcome variables. Patients with pBN and BN had longer QTc intervals and higher rates of additional medical complications reported at presentation than other groups. EDNOS is a medically heterogeneous category with serious physiologic sequelae in children and adolescents. Broadening AN and BN criteria in pediatric patients to include pAN and pBN may prove to be clinically useful.

  5. The Qualitative-Quantitative Analysis and the Study of Personnel's Awareness of the Management Strategies of the Wastes of Medical Diagnostic Laboratories of Rasht, in 2009

    Directory of Open Access Journals (Sweden)

    Nabizadeh R.

    2012-01-01

    Full Text Available Background and Objectives: Waste produced by health and treatment centers (hospitals including medical diagnostic laboratories is one of the sources of municipal waste production. Waste produced by medical diagnostic laboratories due to the existence of pathogens and infectious materials by high importance is one of the environmental issues. This survey has been done on the qualitative-quantitative analytical bases, and the investigation has focused on the management strategies of the waste material of medical diagnostic laboratories of Rasht, Iran in 2009. Methods: In this descriptive study, samples were collected from 19 medical diagnostic laboratories of Rasht in 3 consecutive days (Monday, Tuesday and Wednesday every week, after filling the questionnaire and interviewing with the managers. Then, the samples were separated manually, and divided into 46 different constituents and weighed. Next, the constituents were classified based on characteristics and potentiality of being hazardous.Results: The total amount of annual waste production by the medical diagnostic laboratories of Rasht is 25785.143kg. In this study, the share of manufacturing conventional waste (domestic type wastes, especially infectious, chemical, pharmaceutical, and radioactive wastes were 1.16%, 95.34%, 1.42% and 2.08%, respectively. The highest and lowest amount of waste production relates to plastic materials and wood which are 48.37 and 0.43%, respectively. In this study sharp cutting things were calculated to be 10.52%. Furthermore, 84 percent of the managers of the medical diagnostic laboratories had not had enough information of the circulars and instructions on the enforceable management strategies of the medical wastes.Conclusion: Concerning the management of the medical waste production in the medical diagnostic laboratories, it is suggested that the managers and the personnel be trained on the separation, collection, and disinfection techniques and final disposal

  6. Energy dependence measurement of small-type optically stimulated luminescence (OSL) dosimeter by means of characteristic X-rays induced with general diagnostic X-ray equipment.

    Science.gov (United States)

    Takegami, Kazuki; Hayashi, Hiroaki; Okino, Hiroki; Kimoto, Natsumi; Maehata, Itsumi; Kanazawa, Yuki; Okazaki, Tohru; Hashizume, Takuya; Kobayashi, Ikuo

    2016-01-01

    For X-ray inspections by way of general X-ray equipment, it is important to measure an entrance-skin dose. Recently, a small optically stimulated luminescence (OSL) dosimeter was made commercially available by Landauer, Inc. The dosimeter does not interfere with the medical images; therefore, it is expected to be a convenient detector for measuring personal exposure doses. In an actual clinical situation, it is assumed that X-rays of different energies will be detected by a dosimeter. For evaluation of the exposure dose measured by a dosimeter, it is necessary to know the energy dependence of the dosimeter. Our aim in this study was to measure the energy dependence of the OSL dosimeter experimentally in the diagnostic X-ray region. Metal samples weighing several grams were irradiated and, in this way, characteristic X-rays having energies ranging from 8 to 85 keV were generated. Using these mono-energetic X-rays, the dosimeter was irradiated. Simultaneously, the fluence of the X-rays was determined with a CdTe detector. The energy-dependent efficiency of the dosimeter was derived from the measured value of the dosimeter and the fluence. Moreover, the energy-dependent efficiency was calculated by Monte-Carlo simulation. The efficiency obtained in the experiment was in good agreement with that of the simulation. In conclusion, our proposed method, in which characteristic X-rays are used, is valuable for measurement of the energy dependence of a small OSL dosimeter in the diagnostic X-ray region.

  7. TECHNICAL DIAGNOSTICS AT RUP “BMZ”

    Directory of Open Access Journals (Sweden)

    A. A. Kuzembajev

    2004-01-01

    Full Text Available The review of technical diagnostics and crack detection at RUP “BMZ” is given in the article and there are reflected the functions and tasks of the Laboratory of Technical Diagnostics and Crack detection (LTDandC. The examples of determination of the equipment failure by methods of vibration diagnostics, applied in LTDandC, are given and the efficiency of using of the system of technical servicing of the equipment according to “state” is shown. The idea of transfer from the repairs system “according to schedule” to repairs “according to state” using new information technologies such as vibrating monitoring and vibrating diagnostics is briefly reflected in the article.

  8. Determination of absorbed dose in crystalline and thyroid gland with irradiation protocols applied in orthopantomography equipment for dental examination

    International Nuclear Information System (INIS)

    Munoz A, A. A.; Ramirez A, L. M.; Sosa A, M. A.; Azorin V, J. C.; Vallejo H, M. A.

    2016-10-01

    Ionizing radiations are very useful in the medical field for the diagnostic use of different pathologies. Currently there are different technologies for diagnostic imaging using conventional X-ray, computed tomography, mammography, angiography, dental panoramic X-ray, among others. However, it should be noted that exposure to radiation in this type of diagnostic tests has increased considerably in recent years, because radiological examinations are not always carried out according to the actual clinical needs of each patient, increasing the risk to develop cancer. In this paper, the absorbed dose in the lens and thyroid gland was measured with the help of TLD-100 dosimeters located in a PMMA phantom adapted for orthopantomography (dental panoramic X-ray) equipment in 5 hospitals; using the parameters pre-configured for normal adult for irradiation. A Harshaw 3500 equipment was used to read the dosimeters, obtaining a value of 1.324 ± Sd 0.01 mGy for crystalline and 1.044 ± Sd 0.03 mGy values which are intended to be validated under other conditions and protocols. (Author)

  9. The Design of Diagnostic Medical Facilities where Ionising Radiation is used

    International Nuclear Information System (INIS)

    Malone, J.; O'Reilly, G.; O'Connor, U.; Gallagher, A.; Sheahan, N.; Fennell, S.

    2009-06-01

    The original Code of Practice on The Design of Diagnostic Medical Facilities Using Ionising Radiation was first published by the Nuclear Energy Board in 1988. In the intervening years the 'Blue Book' as it became known has served the medical community well as the sector has expanded and modernised and the late Dr Noel Nowlan, then Chief Executive of the Nuclear Energy Board, deserves much credit for initiating this pioneering contribution to radiation safety in Ireland. There have been significant developments since its publication in terms of the underlying radiation protection legislation, regulatory practice as well as developments in new technologies that have given rise to the need for a revision of the Code. This revised Code is based on a comprehensive draft document produced by the Haughton Institute under contract to the RPII and was finalised following extensive consultations with the relevant stakeholders. The revised Code includes a brief review of the current legislative framework and its specific impact on the management of building projects (Chapters 1 and 2), a presentation of the main types of radiological (Chapter 3) and nuclear medicine (Chapter 4) facilities, a treatment of the technical aspects of shielding calculations (Chapter 5) and a discussion of the practical aspects of implementing shielding solutions in a building context (Chapter 6). The primary purpose of the Code is to assist in the design of diagnostic facilities to the highest radiation protection standards in order to ensure the safety of workers and members of the public and the delivery of a safe service to patients. Diagnostic radiology is a dynamic environment and the Code is intended to be used in consultation with the current literature, an experienced Radiation Protection Advisor and a multidisciplinary project team

  10. Medical Physics Staffing Needs in Diagnostic Imaging and Radionuclide Therapy: An Activity Based Approach [Endorsed by International Organization for Medical Physics

    International Nuclear Information System (INIS)

    2018-01-01

    Over the last decades, the rapid technological development of diagnostic and interventional radiology and nuclear medicine has made them major tools of modern medicine. However, at the same time the involved risks, the growing number of procedures and the increasing complexity of the procedures require competent professional staff to ensure safe and effective patient diagnosis, treatment and management. Medical physicists (or clinically qualified medical physicists) have been recognized as vital health professionals with important and clear responsibilities related to quality and safety of applications of ionizing radiation in medicine. This publication describes an algorithm developed to determine the recommended staffing levels for clinical medical physics services in medical imaging and radionuclide therapy, based on current best practice, as described in international guidelines.

  11. Medical x-ray

    International Nuclear Information System (INIS)

    Abd Aziz Mhd Ramli; Gui Ah Auu; Husaini Salleh; Idris Besar; Mohd Ashhar Khalid; Muhammad Jamal Md Isa; Shaharuddin Mohd; Siti Najila Mohd Janib; Mohamed Ali Abdul Khader; Mahalatchimi Dave; Mohd Fazly Abdul Rahim; Ng Chee Moon; Ram Piari; Teoh Hoon Heng; Lee Peter

    2004-01-01

    This book describes the fundamental subject about medical radiography. It is a multidisciplinary field that requires cross professional input from scientists, engineers and medical doctors. However, it is presented in simple language to suit different levels of readers from x-ray operators and radiographers to physists, general practitioners and radiology specialists.The book is written in accordance to the requirements of the standard syllabus approved by the Ministry of Health Malaysia for the training of medical x-ray operator and general practitioners. In general, the content is not only designed to provide relevant and essential subject for related professionals in medical radiological services such as x-ray operator, radiographer and radiologists, but also to address those in associated radiological services including nurses, medical technologists and physicists.The book is organized and arranged sequentially into 3 parts for easy reference: Radiation safety; X-ray equipment and associated facilities; Radiography practices. With proper grasping of all these parts, the radiological services could be provided with confident and the highest professional standard. Thus, medical imaging with highest quality that can provide useful diagnostic information at minimum doses and at cost effective could be assured

  12. Effect of negative air ions on the potential for bacterial contamination of plastic medical equipment.

    Science.gov (United States)

    Shepherd, Simon J; Beggs, Clive B; Smith, Caroline F; Kerr, Kevin G; Noakes, Catherine J; Sleigh, P Andrew

    2010-04-12

    In recent years there has been renewed interest in the use of air ionizers to control the spread of infection in hospitals and a number of researchers have investigated the biocidal action of ions in both air and nitrogen. By comparison, the physical action of air ions on bacterial dissemination and deposition has largely been ignored. However, there is clinical evidence that air ions might play an important role in preventing the transmission of Acinetobacter infection. Although the reasons for this are unclear, it is hypothesized that a physical effect may be responsible: the production of air ions may negatively charge items of plastic medical equipment so that they repel, rather than attract, airborne bacteria. By negatively charging both particles in the air and items of plastic equipment, the ionizers minimize electrostatic deposition on these items. In so doing they may help to interrupt the transmission of Acinetobacter infection in certain healthcare settings such as intensive care units. A study was undertaken in a mechanically ventilated room under ambient conditions to accurately measure changes in surface potential exhibited by items of plastic medical equipment in the presence of negative air ions. Plastic items were suspended on nylon threads, either in free space or in contact with a table surface, and exposed to negative ions produced by an air ionizer. The charge build-up on the specimens was measured using an electric field mill while the ion concentration in the room air was recorded using a portable ion counter. The results of the study demonstrated that common items of equipment such as ventilator tubes rapidly developed a large negative charge (i.e. generally >-100V) in the presence of a negative air ionizer. While most items of equipment tested behaved in a similar manner to this, one item, a box from a urological collection and monitoring system (the only item made from styrene acrylonitrile), did however develop a positive charge in the

  13. Effect of negative air ions on the potential for bacterial contamination of plastic medical equipment

    Directory of Open Access Journals (Sweden)

    Kerr Kevin G

    2010-04-01

    Full Text Available Abstract Background In recent years there has been renewed interest in the use of air ionizers to control the spread of infection in hospitals and a number of researchers have investigated the biocidal action of ions in both air and nitrogen. By comparison, the physical action of air ions on bacterial dissemination and deposition has largely been ignored. However, there is clinical evidence that air ions might play an important role in preventing the transmission of Acinetobacter infection. Although the reasons for this are unclear, it is hypothesized that a physical effect may be responsible: the production of air ions may negatively charge items of plastic medical equipment so that they repel, rather than attract, airborne bacteria. By negatively charging both particles in the air and items of plastic equipment, the ionizers minimize electrostatic deposition on these items. In so doing they may help to interrupt the transmission of Acinetobacter infection in certain healthcare settings such as intensive care units. Methods A study was undertaken in a mechanically ventilated room under ambient conditions to accurately measure changes in surface potential exhibited by items of plastic medical equipment in the presence of negative air ions. Plastic items were suspended on nylon threads, either in free space or in contact with a table surface, and exposed to negative ions produced by an air ionizer. The charge build-up on the specimens was measured using an electric field mill while the ion concentration in the room air was recorded using a portable ion counter. Results The results of the study demonstrated that common items of equipment such as ventilator tubes rapidly developed a large negative charge (i.e. generally >-100V in the presence of a negative air ionizer. While most items of equipment tested behaved in a similar manner to this, one item, a box from a urological collection and monitoring system (the only item made from styrene

  14. Application of a latent variables model for the medical images analysis; Aplicacion de un modelo de variables latentes para el analisis de imagenes medicas

    Energy Technology Data Exchange (ETDEWEB)

    Campos S, Y.; Ruiz C, S. [Centro de Investigacion en Matematica, A.C. Jalisco s/n, Col. Valenciana, Guanajuato (Mexico)

    2008-07-01

    In recent years the technological advance has allowed the significant advance in diverse research fields, the medicine has not been exempt of this technology and the use of this technology has allowed a significant advance in the equipment that are used to obtain medical images. The quantity of information that is generated with this equipment has grown in exponential form and it is a difficult task to carry out a quantitative analysis of the data also the manipulation of big quantities of information makes the medical images analysis a complicated task. It is in fact this complexity what motivates this work where one of the main objectives is the analysis of techniques that allow to work with the complexity of the data generated with medical equipment. Likewise, it is wanted to illustrate an application of the peaceful uses of the nuclear energy to treat a medical problem where the diagnostic it depends essentially on the current medical equipment to give an appropriate treatment to the patients. (Author)

  15. An engineering development of fluoroscopic X-ray medical equipment based-on fluorescent screen

    International Nuclear Information System (INIS)

    Ferry Suyatno; I Putu Susila; Djoko Sukmono

    2011-01-01

    Fluoroscopic x-ray medical equipment uses fluorescent screen to capture structural image of organs. Unlike conventional x-ray equipment which uses film, in the fluoroscopic x-ray, the resulting image is visualized on the fluorescent screen and directly observed by physicians in the patients' rooms. In this study, we developed an image capture system that transforms the image on the fluorescent screen into digital data, which is then transferred to computer for visualization and further processing. By using this system, the observation of the resulting image can be done on a computer that is placed in the control room. The image can also be stored easily and at low cost compared to conventional film. The experiment shows that the system could be used to capture image of the object. However, its quality needs to be improved. In the future, the system will be modified and tested with different types of cameras to obtain better results. (author)

  16. On-line integration of computer controlled diagnostic devices and medical information systems in undergraduate medical physics education for physicians.

    Science.gov (United States)

    Hanus, Josef; Nosek, Tomas; Zahora, Jiri; Bezrouk, Ales; Masin, Vladimir

    2013-01-01

    We designed and evaluated an innovative computer-aided-learning environment based on the on-line integration of computer controlled medical diagnostic devices and a medical information system for use in the preclinical medical physics education of medical students. Our learning system simulates the actual clinical environment in a hospital or primary care unit. It uses a commercial medical information system for on-line storage and processing of clinical type data acquired during physics laboratory classes. Every student adopts two roles, the role of 'patient' and the role of 'physician'. As a 'physician' the student operates the medical devices to clinically assess 'patient' colleagues and records all results in an electronic 'patient' record. We also introduced an innovative approach to the use of supportive education materials, based on the methods of adaptive e-learning. A survey of student feedback is included and statistically evaluated. The results from the student feedback confirm the positive response of the latter to this novel implementation of medical physics and informatics in preclinical education. This approach not only significantly improves learning of medical physics and informatics skills but has the added advantage that it facilitates students' transition from preclinical to clinical subjects. Copyright © 2011 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  17. Medical History of Elderly Patients in the Emergency Setting: Not an Easy Point-of-Care Diagnostic Marker

    Directory of Open Access Journals (Sweden)

    Tobias Lindner

    2015-01-01

    Full Text Available Background. Medical histories are a crucially important diagnostic tool. Elderly patients represent a large and increasing group of emergency patients. Due to cognitive deficits, taking a reliable medical history in this patient group can be difficult. We sought to evaluate the medical history-taking in emergency patients above 75 years of age with respect to duration and completeness. Methods. Anonymous data of consecutive patients were recorded. Times for the defined basic medical history-taking were documented, as were the availability of other sources and times to assess these. Results. Data of 104 patients were included in the analysis. In a quarter of patients (25%, n=26 no complete basic medical history could be obtained. In the group of patients where complete data could be gathered, only 16 patients were able to provide all necessary information on their own. Including other sources like relatives or GPs prolonged the time until complete medical history from 7.3 minutes (patient only to 26.4 (+relatives and 56.3 (+GP minutes. Conclusions. Medical histories are important diagnostic tools in the emergency setting and are prolonged in the elderly, especially if additional documentation and third parties need to be involved. New technologies like emergency medical cards might help to improve the availability of important patient data but implementation of these technologies is costly and faces data protection issues.

  18. X-ray diagnostics, X-ray therapy, diagnostics and therapy with radioactive materials in free medical practice

    International Nuclear Information System (INIS)

    Setzer, H.D.

    1976-01-01

    On the basis of the documents of the Kassenaerztliche Vereinigung Niederbayerns in Straubing, the work of the established general practicioners in the fields of X-ray and nuclear medicine was investigated for the 1st quarter of 1971, and the X-ray diagnostic services rendered were evaluated according to age and sex. 2/3 of all doctors participating in a health insurance plan in Lower Bavaria are general practitioners; all other fields are represented less often than in Munich. The values for the whole Federal Republic are in between. Internal specialists, radiologists, and urologists together carry out 85.7% of the ten examinations which contribute most to the total gonadal dose. An application of the data on the 1st quarter to the annual value is only possible by allowing for an error of 13.1%. All in all, 6% more X-ray services are administered to men than to women. For both sexes, the genetically most important group of 15-34 resp. 15-39 years of age is highly represented, although young men receive X-ray diagnostics more frequently. X-ray therapy makes up only about 0.5% of all services. Nuclear medical diagnostics is employed to the same extent by radiologists and internal specialists, while therapy with radioactive substances is almost exclusively provided by radiologists. Relative to the population density, radioactive substances are more often used in Lower Bavaria than in West Berlin. (orig.) [de

  19. Cognitive bias in clinical practice – nurturing healthy skepticism among medical students

    Directory of Open Access Journals (Sweden)

    Bhatti A

    2018-04-01

    Full Text Available Alysha Bhatti Faculty of Medicine, Imperial College London, London, UK Abstract: Errors in clinical reasoning, known as cognitive biases, are implicated in a significant proportion of diagnostic errors. Despite this knowledge, little emphasis is currently placed on teaching cognitive psychology in the undergraduate medical curriculum. Understanding the origin of these biases and their impact on clinical decision making helps stimulate reflective practice. This article outlines some of the common types of cognitive biases encountered in the clinical setting as well as cognitive debiasing strategies. Medical educators should nurture healthy skepticism among medical students by raising awareness of cognitive biases and equipping them with robust tools to circumvent such biases. This will enable tomorrow’s doctors to improve the quality of care delivered, thus optimizing patient outcomes. Keywords: cognitive bias, diagnostic error, clinical decision making

  20. Development of a handmade device for collimation and central ray alignment tests in medical X-ray equipment

    International Nuclear Information System (INIS)

    Cruz, B.L. da; Brito, E.B.; Gomes, A.S.

    2017-01-01

    Ordinance 453/98 of the Ministry of Health establishes that medical X-ray equipment should be monitored by tests that prove its efficiency. This practice is called quality control (QC), and two important tests jointly evaluate the operation of the collimation and alignment systems of the central axis of the X-ray beam. The low supply and the high cost generate allegations of difficulties in the periodic realization of the tests. The aim of this work is to design, make and evaluate the performance of a handmade device for the mentioned tests, using low cost materials. Once built, the device had its performance evaluated and compared with the traditionally marketed device. The handmade device proved to be fit in its functions. It is possible to make a device that tests X-ray medical equipment, using the radiology technologist himself as the test runner. Radiation protection is promoted and legislation with no real financial burden

  1. The role of radiology in diagnostic error: a medical malpractice claims review.

    Science.gov (United States)

    Siegal, Dana; Stratchko, Lindsay M; DeRoo, Courtney

    2017-09-26

    Just as radiologic studies allow us to see past the surface to the vulnerable and broken parts of the human body, medical malpractice claims help us see past the surface of medical errors to the deeper vulnerabilities and potentially broken aspects of our healthcare delivery system. And just as the insights we gain through radiologic studies provide focus for a treatment plan for healing, so too can the analysis of malpractice claims provide insights to improve the delivery of safe patient care. We review 1325 coded claims where Radiology was the primary service provider to better understand the problems leading to patient harm, and the opportunities most likely to improve diagnostic care in the future.

  2. Cost-Saving Early Diagnosis of Functional Pain in Nonmalignant Pain: A Noninferiority Study of Diagnostic Accuracy.

    Science.gov (United States)

    Cámara, Rafael J A; Merz, Christian; Wegmann, Barbara; Stauber, Stefanie; von Känel, Roland; Egloff, Niklaus

    2016-01-01

    Objectives. We compared two index screening tests for early diagnosis of functional pain: pressure pain measurement by electronic diagnostic equipment, which is accurate but too specialized for primary health care, versus peg testing, which is cost-saving and more easily manageable but of unknown sensitivity and specificity. Early distinction of functional (altered pain perception; nervous sensitization) from neuropathic or nociceptive pain improves pain management. Methods. Clinicians blinded for the index screening tests assessed the reference standard of this noninferiority diagnostic accuracy study, namely, comprehensive medical history taking with all previous findings and treatment outcomes. All consenting patients referred to a university hospital for nonmalignant musculoskeletal pain participated. The main analysis compared the receiver operating characteristic (ROC) curves of both index screening tests. Results. The area under the ROC curve for peg testing was not inferior to that of electronic equipment: it was at least 95% as large for finger measures (two-sided p = 0.038) and at least equally as large for ear measures (two-sided p = 0.003). Conclusions. Routine diagnostic testing by peg, which is accessible for general practitioners, is at least as accurate as specialized equipment. This may shorten time-to-treatment in general practices, thereby improving the prognosis and quality of life.

  3. Development of cancer medical treatment/diagnostic equipment using the source of X-rays in space coherence

    International Nuclear Information System (INIS)

    Sato, Isamu; Shintomi, Kazutaka; Hayakawa, Ken

    2009-01-01

    In Nihon University, the research and development of Parametric X-rays radiation (PXR) by the 100 MeV electron linac are advanced. It was proved by basic experiment that PXR was a source of coherent X-rays. Coherent X-rays have the characteristic that a refraction action is guided with an irradiation matter. According to this action, the contrast image pick-up of an irradiation matter is attained, and X-rays becomes possible to focus a point itself. Research of cancer medical treatment and diagnosis are advanced using the new source of X-ray. Miniaturization of the source is important for the spread of cancer medical new treatment and diagnoses. Recently, the tabletop type 100 MeV class cryogenic linac with energy recovery is under development. In symposium, we report progress of these research and development. (author)

  4. Risk factors of coronary heart disease among medical diagnostic X-ray workers

    International Nuclear Information System (INIS)

    Zhang Wei; Wang Jixian; Zhao Yongcheng; Li Benxiao; Fan Tiqiang; Zhao Zhigang; Lin Zhidong

    2002-01-01

    Objective: To investigate risk factors of coronary heart disease (CHD) in medical diagnostic X-ray workers in China, especially the relationship of CHD with occupational irradiation. Methods: A 1:2 matched case-control study was carried out. The study subjects consisted of 112 pair-matched cases and controls coming from different hospitals in China. Information about occupational and non-occupational risk factors obtained by interviewing every subjects personally. Individual doses were estimated by normalized work load method. SAS 6.12 software conditional Logistic regression method was applied to data analysis. Results: Variables such as family history of CHD (OR=17.298, P = 0.0001), history of hypertension (OR = 6.172, P = 0.0003), overweight (OR = 2.679, P = 0.0150), physical exercises (OR = 0.421, P0.0333), diabetes (OR = 7.823, P = 0.0200), radiation protection condition (OR = 3.992, P 0.0027), and accumulated radiation dose (OR = 1.612, P 0.0454) were included in the last model. Conclusions: For the medical diagnostic X-ray workers, family history of coronary heart disease, history of hypertension, diabetes, etc. are the main risk factors of CHD, and occupational exposure may be a potential risk factor. As for the mechanism, further studies are needed

  5. Visualizing and measuring the temperature field produced by medical diagnostic ultrasound using thermography

    International Nuclear Information System (INIS)

    Vachutka, J; Grec, P; Mornstein, V; Caruana, C J

    2008-01-01

    The heating of tissues by diagnostic ultrasound can pose a significant hazard particularly in the imaging of the unborn child. The demonstration of the temperature field in tissue is therefore an important objective in the teaching of biomedical physics to healthcare professionals. The temperature field in a soft tissue model was made visible and measured using thermography. Temperature data from the images were used to investigate the dependence of temperature increase within the model on ultrasound exposure time and distance from the transducer. The experiment will be used within a multi-professional biomedical physics teaching laboratory for enhancing learning regarding the principles of thermography and the thermal effects of ultrasound to medical and healthcare students and also for demonstrating the quantitative use of thermographic imaging to students of biophysics, medical physics and medical technology

  6. Evaluation of TLD dose response compared to MCNP-5 simulation of diagnostic X ray equipment - radiation diagnostic image

    International Nuclear Information System (INIS)

    Sanchez G, R.; Cavalieri, T. A.; De Paiva, F.; Dalledone S, P. de T.; Yoriyaz, H.; Rodrigues F, M. A.; Vivolo, V.

    2014-08-01

    The thermo luminescent dosimeter (TLD) is used as a radiation dosimeter and can be used as environmental and staff personnel monitoring. The TLD measures ionizing radiation exposure by a process in which the amount of radiation collected by the dosimeter is converted in visible light when the crystal is heated. The amount of emitted light is proportional to the radiation exposure, and then the response of the TLD must be the related to the real dose. In this work it was used twenty four TLD 700 in order to obtain eight values of doses from a diagnostic X-ray equipment. The TLD-700 is a LiF TLD enriched with 7 Li isotope. One way to compare and study the response of TLD is by Monte Carlo method, which has been used as a computational tool to solve problems stochastically. This method can be applied to any geometry, even those where the boundary conditions are unknown, making the method particularly useful to solve problems a priori. In this work it was modeled the X-ray tube exactly as the one used to irradiate the TLD, after the simulation and the TLD irradiation the results of dose value from both were compared. (Author)

  7. Evaluation of TLD dose response compared to MCNP-5 simulation of diagnostic X ray equipment - radiation diagnostic image

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez G, R.; Cavalieri, T. A.; De Paiva, F.; Dalledone S, P. de T.; Yoriyaz, H. [Instituto de Pesquisas Energeticas e Nucleares, Centro de Engenharia Nuclear / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil); Rodrigues F, M. A. [Universidade Estadual Paulista, Faculdade de Medicina de Botucatu, Departamento de Dermatologia e Radioterapia, Av. Prof. Montenegro s/n, Rubiao Junior, 18601-970 Botucatu (Brazil); Vivolo, V., E-mail: chancez@hotmail.com [Instituto de Pesquisas Energeticas e Nucleares, Gerencia de Metrologia das Radiacoes / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil)

    2014-08-15

    The thermo luminescent dosimeter (TLD) is used as a radiation dosimeter and can be used as environmental and staff personnel monitoring. The TLD measures ionizing radiation exposure by a process in which the amount of radiation collected by the dosimeter is converted in visible light when the crystal is heated. The amount of emitted light is proportional to the radiation exposure, and then the response of the TLD must be the related to the real dose. In this work it was used twenty four TLD 700 in order to obtain eight values of doses from a diagnostic X-ray equipment. The TLD-700 is a LiF TLD enriched with {sup 7}Li isotope. One way to compare and study the response of TLD is by Monte Carlo method, which has been used as a computational tool to solve problems stochastically. This method can be applied to any geometry, even those where the boundary conditions are unknown, making the method particularly useful to solve problems a priori. In this work it was modeled the X-ray tube exactly as the one used to irradiate the TLD, after the simulation and the TLD irradiation the results of dose value from both were compared. (Author)

  8. Radiation doses to patients in medical diagnostic x-ray examinations in New Zealand: a 1983-84 survey

    International Nuclear Information System (INIS)

    Williamson, B.D.P.; Poletti, J.L.; Cartwright, P.H.; Le Heron, J.C.

    1993-06-01

    A survey of doses to patients undergoing diagnostic x-ray examinations was performed in 1983-84. Developments since 1983-84 were reviewed and estimates made of the frequency of x-ray examinations, and doses to patients, as at 1992. The collective effective dose from general medical diagnostic radiology in 1983-84 was estimated to have been about 443 μSv per capita per annum. The figure excluded computed tomography which was estimated to have contributed about 5.6 μSv per capita per annum and mammography gave 0.3 μSv per annum. The total per capital effective dose from all medical diag over the whole period from 1983-84 to 1992. The highest dose examinations in 1983-84 were the fluoroscopic procedures barium enema and meal. Over the whole period 1983-84 to 1992 the genetically significant dose (GSD) to the population of New Zealand from medical diagnostic radiology was estimated to have been in the range 200-250 μSv per capita per annum. The two opposing tendencies noted for effective dose, viz, the fall in frequency of some examination types and the rise of Computed tomography, acted also upon this dose index. 43 refs., tabs., figs., ills

  9. An epidemiologic investigation of cancers among medical diagnostic X-ray workers of 1950-1996 in Jiangsu province

    International Nuclear Information System (INIS)

    Yu Ningle; Wang Jin; Xu Cuizhen; Hu Lianzhi; Hou Bijun

    2001-01-01

    Objective: To research the phenomenon and characteristic of radiation oncogenesis among medical diagnostic X-ray workers. Methods: The cancer incidence data of the fixed cohort from the beginning of 1950 to the end of 1996 were collected. The estimates of relative risk (RR) were calculated by AMFIT in Epicure (Hirosoft International Corp, 1988-1992). Results: During the period of 1950-1996 there were 312 cancers among 215 355 person-years at risk in a cohort of 7701 subjects, including, medical diagnostic X-ray workers and workers of other departments in the same hospitals. The RR adjusted for sex and age for overall cancers was more than 1. The incidence of female breast cancer increased significantly (RR = 3.3, 95%, CI = 1.39 - 8.07), and the relative risks for solid cancer and leukemia were 1.2 and 2.6, respectively. The average age of occurrence of malignant tumors was moved up from 55.0 years in the controls to 51.3 years in the X-ray workers. Conclusions: There is a positive effect of radiation oncogenesis on medical diagnostic X-ray workers, although the sample size is not large enough to make a definite overall conclusion statistically. Further follow-up is needed

  10. A flexible mobile-device biosensing instrumentation platform for point-of-care medical diagnostics applications

    DEFF Research Database (Denmark)

    Patou, François; Pfreundt, Andrea; Zulfiqar, Azeem

    2014-01-01

    helping to address this challenge. Specifically, Lab-on-Chip (LoC) devices have a key role to play in the advent of Point-of-Care (PoC) medical applications, driving a shift of the medical diagnostics paradigm and the transition from a centralized, technical, high-throughput biological sample analysis...... programmable electrical readout from LoCs potentially comprehending varied transducers addressing different targeted biological markers. A smart-phone/tablet docking-station embeds the hardware interface necessary for the implementation of a smart-phone digital lock-in amplifier. The platform is tested...

  11. Advance of the National Program of Radiological Protection and Safety for medical diagnostic with X-rays

    International Nuclear Information System (INIS)

    Verdejo S, M.

    1999-01-01

    The National Program of Radiological Protection and Safety for medical diagnostic with X-ray (Programa Nacional de Proteccion y Seguridad Radiologica para diagnostico medico con rayos X) was initiated in the General Direction of Environmental Health (Direccion General de Salud Ambiental) in 1995. Task coordinated with different dependences of the Public Sector in collaboration between the Secretary of Health (Secretaria de Salud), the National Commission of Nuclear Safety and Safeguards (Comision Nacional de Seguridad Nuclear y Salvaguardias) and, the National Institute of Nuclear Research (Instituto Nacional de Investigaciones Nucleares). The surveillance to the fulfilment of the standardization in matter of Radiological Protection and Safety in the medical diagnostic with X-rays has been obtained for an important advance in the Public sector and it has been arousing interest in the Private sector. (Author)

  12. Integrating Nursing Diagnostic Concepts into the Medical Entities Dictionary Using the ISO Reference Terminology Model for Nursing Diagnosis

    OpenAIRE

    Hwang, Jee-In; Cimino, James J.; Bakken, Suzanne

    2003-01-01

    Objective: The purposes of the study were (1) to evaluate the usefulness of the International Standards Organization (ISO) Reference Terminology Model for Nursing Diagnoses as a terminology model for defining nursing diagnostic concepts in the Medical Entities Dictionary (MED) and (2) to create the additional hierarchical structures required for integration of nursing diagnostic concepts into the MED.

  13. Exposure of the bulgarian population from diagnostic radiology during 2001/2006 y

    International Nuclear Information System (INIS)

    Kostova-Lefterova, D.; Ingilizova, K.

    2008-01-01

    Each Member State of the European Union is currently committed to produce national legislation, demonstrating conformity with the European Directive on medical exposures. According to the Directive, each country shall estimate the medical exposure of its population. For this purpose it is necessary to calculate the individual effective dose from each type of diagnostic radiology examination and the frequency of the examinations. The collective effective dose (CED) is disputable indicator for the medical exposures but it is a criterion for the level of the country on the radiation protection of persons undergoing medical exposure. The individual effective doses from each type of diagnostic radiology examination will depend on the patient's age, sex, weight, the number and type of images, the screening time and also the equipment used. Some mean values can be obtained through surveys of patient dose and compared with the national or European reference doses for 'standard sized' patients. The aim of this investigation is to assess the exposure of Bulgarian population undergoing diagnostic radiology examinations. The diagnostic radiology procedures are in 30 positions, distributed in 3 age groups: 0 - 17 y., 17 - 45 y. and over 45 y. For the assessment of the CED the generally accepted formula has been applied. The individual effective doses have been established on the basis of standard tablegrams for the radiographic diagnostic examinations and the results from the national research project 'Phare' in 2002. Presented data are: average number of examinations 3848.92x10 3 , frequency in thousands 500, annual effective individual dose 0.89 mSv/y and average annual collective effective dose - 3314.59 man.Sv/y. The mean effective dose per caput of population for medical exposures can then be compared with that of other countries having similar levels of health care. Comparisons can also be made with exposure of the population from other sources of radiation. The dynamics

  14. Application of the new International Code of Practice for dosimetry in diagnostic radiology to conventional exams

    International Nuclear Information System (INIS)

    Martinez Gonzalez, A.; Cardenas Herrera, J.; Walwyn Salas, G.; Machado, A.; Mora Machado, R. de la

    2008-01-01

    Full text: During the recent years, a policy for updating and installation of the X-ray equipment, specialized as well as conventional, have been carrying out, in Cuba. Conventional equipment has reached almost the whole primary level. Considering this situation, the quality control programs and clinical dosimetry have become even more important. Regarding the last one, an International Code of Practice for Dosimetry in Diagnostic Radiology had been published by the International Atomic Energy Agency in order to been used as a guide and to standardize the methodologies used to evaluate the patient exposure in radiodiagnostic. Taken into consideration the above reasons, an assessment of the aforementioned code of practice was done in order to choose the most feasible methodology to implement in the country. The evaluation was performed considering the lack of dosimetric equipment and medical physicists in this practice, in the interests of increasing the measurements scope to a large number of services as well as to standardize the methodology on a national scale. The present work shows the results obtained from the application of the new code of practice to conventional radiology exams in some medical institutions. Out of 3 on patients measurements methodologies described in the code of practice, the one of measurement of the incident air kerma was chosen. This methodology allow to the physicist to focus on the diagnostic equipment tests and to delegate the collection of the patient and exposure parameters data to the technicians, which make the increased of the patient and diagnostic departments sample, possible. The measurements were carried out in 2 hospital of the capital. The exams involved in the assessments were thorax PA, lumbar spine AP and lumbar spine LAT. In every diagnostic service, 25 patients were chosen on each projection. The weight and height average of the patient sample were 68 kg and 167 cm respectively. In the assessment were considered only

  15. Enhancement of equipment services for Kozloduy NPP

    International Nuclear Information System (INIS)

    Schultz, Christophe

    2013-01-01

    Conclusion After 5 years of maintenance services, KNPP and AREVA have continuously intensified their partnership Close cooperation between KNPP, AREVA Local Office Engineers and OEM experts Involvement of sophisticated tools for diagnostics and condition monitoring Performance of engineering services and obsolescence evaluation Possibilities to perform equipment modernization of Electrical and IC equipment in future

  16. The study on cytogenetic analysis and dosimetry reconstruction for medical diagnostic X-ray workers using G-banding and fluorescence in situ hybridization

    International Nuclear Information System (INIS)

    Li Jin; Wang Qin; Tang Weisheng; Sun Yuanming; Wang Zhiquan

    2003-01-01

    Objective: To estimate the dose of medical diagnostic X-ray workers. Methods: The chromosome aberrations were analyzed by G-banding or FISH in medical diagnostic X-ray workers with different calendar years of entry. Results: The biological doses estimated by the two methods were in agreement with the doses evaluated by physical methods. Conclusion: G-banding and FISH are effective ways to analyse the chromosome translocations

  17. Translating silicon nanowire BioFET sensor-technology to embedded point-of-care medical diagnostics

    DEFF Research Database (Denmark)

    Pfreundt, Andrea; Zulfiqar, Azeem; Patou, François

    2013-01-01

    Silicon nanowire and nanoribbon biosensors have shown great promise in the detection of biomarkers at very low concentrations. Their high sensitivity makes them ideal candidates for use in early-stage medical diagnostics and further disease monitoring where low amounts of biomarkers need to be de......Silicon nanowire and nanoribbon biosensors have shown great promise in the detection of biomarkers at very low concentrations. Their high sensitivity makes them ideal candidates for use in early-stage medical diagnostics and further disease monitoring where low amounts of biomarkers need...... to be detected. However, in order to translate this technology from the bench to the bedside, a number of key issues need to be taken into consideration: Integrating nanobiosensors-based technology requires to overcome the difficult tradeoff between imperatives for high device reproducibilty and associated...... rising fabrication costs. Also the translation of nano-scale sensor technology into daily-use point-of-care devices requires acknowledgement of the end-user requirements, making device portability and human-interfacing a focus point in device development. Sample handling or purification for instance...

  18. 77 FR 6915 - Medical Diagnostic Equipment Accessibility Standards

    Science.gov (United States)

    2012-02-09

    ... have limited stamina or other conditions that affect their ability to maintain balance. Mammography... of cell foam), the upholstery may compress or deflect during use. If the height of the transfer...

  19. In-phantom spectrometry of medical diagnostic x rays

    International Nuclear Information System (INIS)

    Stansbury, P.S.

    1977-10-01

    A program of measurements was made to determine the spectral fluence distributions at locations of significance in a heterogeneous, hominoid phantom exposed to x rays in a manner simulating medical diagnostic radiology. The measurements were made with a specially constructed NaI(Tl) scintillation detector. The detector had a spherically shaped active volume 0.6 cm in diameter. The resolution of this detector was five times worse than that of a more conventional NaI(Tl) spectrometer. Resolution broadening and other distortions were removed from the observed pulse height spectra with a computer-coded, iterative unfolding technique. The performance of the spectrometer and the unfolding scheme was assessed by comparing, in a few cases, the unfolded NaI(Tl) spectra with spectra determined with a high resolution Ge(Li) spectrometer. The measurements were made in a physical model of an idealized representation of an average adult patient

  20. In-phantom spectrometry of medical diagnostic x rays

    Energy Technology Data Exchange (ETDEWEB)

    Stansbury, P. S.

    1977-10-01

    A program of measurements was made to determine the spectral fluence distributions at locations of significance in a heterogeneous, hominoid phantom exposed to x rays in a manner simulating medical diagnostic radiology. The measurements were made with a specially constructed NaI(Tl) scintillation detector. The detector had a spherically shaped active volume 0.6 cm in diameter. The resolution of this detector was five times worse than that of a more conventional NaI(Tl) spectrometer. Resolution broadening and other distortions were removed from the observed pulse height spectra with a computer-coded, iterative unfolding technique. The performance of the spectrometer and the unfolding scheme was assessed by comparing, in a few cases, the unfolded NaI(Tl) spectra with spectra determined with a high resolution Ge(Li) spectrometer. The measurements were made in a physical model of an idealized representation of an average adult patient.

  1. Medical capsule robots: A renaissance for diagnostics, drug delivery and surgical treatment.

    Science.gov (United States)

    Mapara, Sanyat S; Patravale, Vandana B

    2017-09-10

    The advancements in electronics and the progress in nanotechnology have resulted in path breaking development that will transform the way diagnosis and treatment are carried out currently. This development is Medical Capsule Robots, which has emerged from the science fiction idea of robots travelling inside the body to diagnose and cure disorders. The first marketed capsule robot was a capsule endoscope developed to capture images of the gastrointestinal tract. Today, varieties of capsule endoscopes are available in the market. They are slightly larger than regular oral capsules, made up of a biocompatible case and have electronic circuitry and mechanisms to capture and transmit images. In addition, robots with diagnostic features such as in vivo body temperature detection and pH monitoring have also been launched in the market. However, a multi-functional unit that will diagnose and cure diseases inside the body has not yet been realized. A remote controlled capsule that will undertake drug delivery and surgical treatment has not been successfully launched in the market. High cost, inadequate power supply, lack of control over drug release, limited space for drug storage on the capsule, inadequate safety and no mechanisms for active locomotion and anchoring have prevented their entry in the market. The capsule robots can revolutionize the current way of diagnosis and treatment. This paper discusses in detail the applications of medical capsule robots in diagnostics, drug delivery and surgical treatment. In diagnostics, detailed analysis has been presented on wireless capsule endoscopes, issues associated with the marketed versions and their corresponding solutions in literature. Moreover, an assessment has been made of the existing state of remote controlled capsules for targeted drug delivery and surgical treatment and their future impact is predicted. Besides the need for multi-functional capsule robots and the areas for further research have also been

  2. Tasks of physicists and graduated engineers in diagnostic radiology

    International Nuclear Information System (INIS)

    Angerstein, W.

    1987-01-01

    The tasks of physicists and engineers in diagnostic radiology are compiled and trends of development are discussed. Specific duties can be selected from these tasks for each department and physicist individually. An attempt is made to characterize the specific tasks of medical physics. The most important tasks are concerning subjects of (1) investment planning, (2) quality control and quality assurance, (3) service and maintenance, (4) radiation protection and electrical safety, (5) development, testing and adaption of equipment, (6) assistance in running the radiologic department, (7) research, (8) pre- and postgraduate training, (9) educational training, (10) miscellaneous. (author)

  3. Diagnostic imaging over the last 50 years: research and development in medical imaging science and technology

    International Nuclear Information System (INIS)

    Doi, Kunio

    2006-01-01

    Over the last 50 years, diagnostic imaging has grown from a state of infancy to a high level of maturity. Many new imaging modalities have been developed. However, modern medical imaging includes not only image production but also image processing, computer-aided diagnosis (CAD), image recording and storage, and image transmission, most of which are included in a picture archiving and communication system (PACS). The content of this paper includes a short review of research and development in medical imaging science and technology, which covers (a) diagnostic imaging in the 1950s, (b) the importance of image quality and diagnostic performance, (c) MTF, Wiener spectrum, NEQ and DQE, (d) ROC analysis, (e) analogue imaging systems, (f) digital imaging systems, (g) image processing, (h) computer-aided diagnosis, (i) PACS, (j) 3D imaging and (k) future directions. Although some of the modalities are already very sophisticated, further improvements will be made in image quality for MRI, ultrasound and molecular imaging. The infrastructure of PACS is likely to be improved further in terms of its reliability, speed and capacity. However, CAD is currently still in its infancy, and is likely to be a subject of research for a long time. (review)

  4. Upgrading the Medical Physics Calibration Laboratory Towards ISO/IEC 17025: Radiation Standards and Calibration in Diagnostic Radiology

    International Nuclear Information System (INIS)

    Asmaliza Hashim; Muhammad Jamal Md Isa; Abd Aziz Mhd Ramli; Wan Hazlinda Ismail; Norhayati Abdullah; Shahrul Azlan Azizan; Siti Sara Deraman; Nor Azlin Azraai; Md Khairusalih Md Zin

    2010-01-01

    Calibration of quality control (QC) test tools used in diagnostic radiology is legally required under the Ministry of Health (MOH) requirement. The Medical Physics Calibration Laboratory of the Malaysian Nuclear Agency is the national focal point for the calibration of quality control test tools used in diagnostic radiology. The Medical Physics Calibration Laboratory has measurement traceability to primary standard dosimetry laboratory (Physikalisch-Technische Bundesanstalt (PTB)), thus providing an interface between the primary standard dosimetry laboratory and Malaysian hospitals, clinics and license class H holder. The Medical Physics Calibration Laboratory facility is comprised of a constant potential x-ray system with a capability of 160 kV tube and a series of reference and working standard ion chambers. The stability of reference and working standard ion chambers was measured using strontium-90. Dosimetric instruments used in diagnostic radiology is calibrated in terms of air kerma to comply with an International Code of Practices of dosimetry for example IAEA's Technical Report Series number 457. The new series of standard radiation qualities was established based on ISO/IEC 61267. The measurement of beam homogeneity was measured using film and ion chamber to define the field size at certain distance and kV output was measured using the spectrometer and non-invasive kVp meter. The uncertainties measurement was determined with expended uncertainties to a level of confidence of approximately 95% (coverage factor k=2). This paper describes the available facility and the effort of the Medical Physics Calibration Laboratory to upgrade the laboratory towards ISO/IEC 17025. (author)

  5. Radiosterilization and other sterilization methods of medical equipment on Kilmer's conference, Brussels, 12-16 June 1993

    International Nuclear Information System (INIS)

    Zagorski, Z.P.

    1993-01-01

    The Johnson and Johnson Co. organized the scientific conference devoted to different aspects and methods of sterilization of medical equipment and materials. A condensed review of the main problems discussed during the conference has been done. Attention has been paid especially on: actual problems with primary infections control, problems of sterilization in pharmacy, hazards problems, investigations and control methods and radiation sterilization. 2 figs

  6. Unintentional exposure to radiation during pregnancy from nuclear medical diagnostic procedures; Unabsichtliche Strahlenexposition in der Schwangerschaft durch nuklearmedizinische Diagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Moka, D. [Gemeinschaftspraxis fuer Radiologie und Nuklearmedizin, Essen (Germany)

    2005-12-01

    The administration of radiopharmaceuticals during pregnancy is contraindicated due to a lack of vital indications. However, if prenatal exposure to radiation should occur in the framework of a nuclear medical diagnostic procedure then fortunately no longterm side-effects would normally be expected. Radiation damage in the preimplantation phase leads to early abortion. However, if the further course of pregnancy remains uncomplicated then no subsequent side-effects need be expected. On a conservative estimate, it would require doses exceeding 50 mGy to cause radiation damage within the uterus after the preimplantation phase. However, the standard radioactivities applied for diagnostic purposes in nuclear medicine, can be obtained with doses of less than 20 mGy. On the basis of current knowledge, therefore, there is no reason to terminate pregnancy on medical grounds after diagnostic exposure to radiopharmaceuticals. (orig.)

  7. The potential of high resolution melting analysis (hrma) to streamline, facilitate and enrich routine diagnostics in medical microbiology.

    Science.gov (United States)

    Ruskova, Lenka; Raclavsky, Vladislav

    2011-09-01

    Routine medical microbiology diagnostics relies on conventional cultivation followed by phenotypic techniques for identification of pathogenic bacteria and fungi. This is not only due to tradition and economy but also because it provides pure culture needed for antibiotic susceptibility testing. This review focuses on the potential of High Resolution Melting Analysis (HRMA) of double-stranded DNA for future routine medical microbiology. Search of MEDLINE database for publications showing the advantages of HRMA in routine medical microbiology for identification, strain typing and further characterization of pathogenic bacteria and fungi in particular. The results show increasing numbers of newly-developed and more tailor-made assays in this field. For microbiologists unfamiliar with technical aspects of HRMA, we also provide insight into the technique from the perspective of microbial characterization. We can anticipate that the routine availability of HRMA in medical microbiology laboratories will provide a strong stimulus to this field. This is already envisioned by the growing number of medical microbiology applications published recently. The speed, power, convenience and cost effectiveness of this technology virtually predestine that it will advance genetic characterization of microbes and streamline, facilitate and enrich diagnostics in routine medical microbiology without interfering with the proven advantages of conventional cultivation.

  8. Radiographic quality and radiation protection in general medical practice and small hospitals

    International Nuclear Information System (INIS)

    Williamson, B.D.P.; Le Heron, J.C.

    1988-01-01

    Radiation protection and image quality were assessed in a survey of 22 general medical practices (GP) and the 24 smallest hospitals with x-ray facilities. Limited radiography, usually of extremities for trauma, was being performed in these facilities since access to regular radiology services was restricted, mainly for geographic reasons. An anthropomorphic phantom foot and ankle with two simulated fractures of the lateral and medical malleoli was presented at each facility for radiography, and the resulting films assessed for radiographic technique and basic diagnostic usefulness. The x-ray equipment was adequate for the range of procedures performed. While the standard of radiographic techniques was lower than in regular x-ray departments, most films of the phantom ankle were still diagnostically useful and only four were rejected entirely. The principal deficiency in general practice x-ray was in darkrooms and x-ray film processing. Consultation in this regard with registered medical radiation technologists is recommended. Generally, the x-ray equipment and working procedures complied with the National Radiation Laboratory Code of Safe Practice for the Use of X-rays in Diagnosis (Medical). Radiation doses to the phantom ankle ranged widely for effectively the same procedure, although none was excessive. Improved x-ray film processing, and tighter x-ray beam collimation, would result in a narrower range of doses to patients. Personnel exposures to radiation were satisfactorily low and special shieldings are not required in general practice. (author). 7 refs., 4 figs., 2 tabs

  9. Studies on optimization of radiation protection for patients in diagnostic radiology

    International Nuclear Information System (INIS)

    Wei, Z.; Zhang, Q.; Li, W.; Li, K.; Wei, L.; Zong, X.; Qiang, Z.; Wu, Y.

    1994-01-01

    For the exposure of patients in diagnostic radiology, individual dose limit does not apply, but optimization of radiological protection may play a major role. This project has been carried out with the purpose of improving the protection of patients in medical diagnostic radiology in China utilizing the principles of optimization. Taking Sichuan, Shandong and Beijing as surveyed areas, we investigated the present situation of the protection of patients. In the survey, the patient doses were classified into practical dose, justified dose and optimized dose to evaluate the influences of managerial and equipment factors separately. The results show that there are some urgent protection problems in X-ray protection to be solved in the surveyed regions. This paper, however, points out that the prospects of reducing patient doses are encouraging provided that appropriate measures are adopted. For instance, taking proper managerial measures without radical change of existing equipments may reduce patient doses in chest fluoroscopy and radiography by 40% and 18% respectively; refitting some equipment may reduce the doses by 82.4% in chest fluoroscopy, 66% in chest radiography, and 80% in barium meal examination of the gastrointestinal (GI) tract. Using chest radiography instead of fluoroscopy supplemented by other protection measures may reduce the doses by 91.7%. Optimization analysis shows that adoption of the above measures conforms to the principle of optimization of radiation protection. (authors). 5 refs., 7 tabs

  10. 171 ROYAL DECREE 1891/1991 of 30 December 1991 on the installation and use of X-ray equipment for the purposes of medical diagnosis

    International Nuclear Information System (INIS)

    1992-01-01

    The Decree lays down the rules enabling government authorities to monitor the proper functioning of such appliances. It takes account of the Council of European Communities' Directive 80/836/Euratom amended by Directive 84/466/Euratom on basic safety standards for the health protection of the general public and workers against the dangers of ionization and Directive 84/467/Euratom laying down basic measures for the radiation protection of persons undergoing medical examination or treatment. The Decree provides for a register of firms authorised to sell and maintain medical X-ray equipment, and a register of the equipment installed. It also sets out requirements relating to third party liability insurance, and to the qualifications and training of personnel operating the equipment. (NEA)

  11. EXPERIENCE IN DEVELOPMENT MEDICAL KITS FOR MEDICAL SERVICES OF THE RUSSIAN FEDERATION ARMED FORCES

    Directory of Open Access Journals (Sweden)

    E. O. Rodionov

    2016-01-01

    Full Text Available Introduction. The development of modern, complete-standard issue equipment for the Armed Forces Medical Service is an urgent organizational and management task. First aid kits, medical bags, sets of medical equipment, medical kits and packing existed until recently; no longer meet modern requirements for a number of objective reasons. The aim of the study was the formation of programs of development of modern samples of complete-standard-issue equipment. Materials and methods. The study was conducted based on the analysis of scientific literature and guidelines which regulate different aspects of the Armed Forces Medical Service complete-standard issue equipment. The study used methods like: retrospective, content analysis, comparison and description, logical, structural and functional analysis, expert assessments, decision-making, as well as the methods of the theory of constraints and other systems. Results and discussion. rmation of the range of medical property in modern conditions for inclusion into complete-standard issue equipment is connected with the need to make timely decisions on choosing the most efficient models, taking into account market conditions and economic opportunities. There are requirements established for the complete-samples standard issue equipment for their use outside a medical organization. Development program structure of complete-standard-issue equipment is shown, as well as examples of the formation of the content of medical equipment kits. On the basis of the offered program a new complete-standard issue equipment of the Armed Forces Medical Service was created. In accordance with the principles of the theory of constraints a strategy to optimize the composition of sets of medical equipment was developed. It included comprehensive solutions aimed at stabilizing the activity of the pharmaceutical industry in the interest of the Armed Forces Medical Service. Conclusions. An offered program has allowed developing

  12. Study of results of prophylactic medical examination of personnel of radioisotope diagnostic laboratories

    International Nuclear Information System (INIS)

    Mokrousova, Eh.V.

    1988-01-01

    Preliminary results of the analysis of frequency of revealed diseases in radiological diagnostic personnel of leningrad medical establishments are given. A close connection between the frequency of revealed diseases and the age is more manifested than between the frequency of revealed diseases and personnel length of service. By the end of occupational activity the frequency of radiological personnel diseases doesn't exceed the similar frequency in population. 3 refs; 2 tabs

  13. Noncancer death for medical diagnostic X-ray workers in China, 1950-1995

    International Nuclear Information System (INIS)

    Jia Weihua; Wang Jixian; Li Benxiao; Zhao Yongcheng; Zhang Jingyuan

    2002-01-01

    Objective: To investigate occupational radiation exposure effects on human non-cancer diseases. Methods: A cohort study for medical diagnostic X-ray workers and medical workers who never engaged in X-ray work was carried out. Results: The significantly enhanced noncancer deaths for X-ray workers were showed as follows: ischemic heart disease, RR was 1.39 ( P < 0.01 ); cerebrovascular disease, RR = 1.36 ( P < 0.01 ); aplastic anemia, RR = 10.35 (P < 0.01 ); disease of the nervous system, RR = 2.06 (P < 0.01); disease of the skin and subcutaneous tissues, RR = 3.23 (P < 0.05). Conclusions: Long-term occupational X-ray irradiation can enhance the overall risk of deaths, in which, risk for heart disease, cerebrovascular disease and aplastic anemia deaths may significantly related to the occupational exposure

  14. Current aspects in the development of the quality control in the conventional X-ray diagnostic radiology

    International Nuclear Information System (INIS)

    Stoeva, M.; Velkova, K.

    2004-01-01

    The role of the X-ray diagnostic radiology as one of the main factors forming the general public dose is indisputable. Following the requirement for justification of the application of X-rays for medical purposes, certain criteria for assessment of the parameters of the X-ray diagnostic equipment are formed and maximum permissible values defined. The latter are developed by the international and national radiation protection organizations and introduced both in the international and national legislation. The importance of the quality assurance concept for the radiation protection of the patient and staff in diagnostic radiology turned the quality control into main toll for obtaining high quality images with minimum dose to the patient and staff. X-ray diagnostics is one of the most common methods used in the medical practice. This is the main reason for the increase of the quality control protocols, winch makes their handling difficult. The latest developments in this area bring forward the idea for the development of specialized quality control software, which is capable of: 1) full or semi-automated calculation and assessment of the parameters of the X-ray diagnostic units; 2) tools for data handling and access; 3) tools for data analysis based on predefined procedures

  15. Diagnostic planning in JT-60 project

    International Nuclear Information System (INIS)

    Matoba, Tohru; Suzuki, Yasuo; Funahashi, Akimasa; Itagaki, Tokiyoshi

    1977-08-01

    The diagnostic plans of JT-60 were made along with design of the main machine. Basic requirements of the diagnostic program are (1) multiple measurement of respective plasma parameters, (2) efficient usage of the discharge, (3) capable data acquisition system, (4) high reliability of the diagnostic equipments, and (5) systematic development of new diagnostic techniques. Dimensions of the diagnostic ports were determined in detailed design of the vacuum vessel, anticipating the possible diagnostic methods. The proposed diagnostic systems and the plans are shown in table and figures respectively. Problems in the diagnostics are also described. (auth.)

  16. Diagnostic Imaging Workshop

    International Nuclear Information System (INIS)

    Sociedad Argentina de Fisica Medica

    2012-01-01

    The American Association of Physicist in Medicine (AAPM), the International Organization for Medical Physics (IOMP) and the Argentina Society of Medical Physics (SAFIM) was organized the Diagnostic Imaging Workshop 2012, in the city of Buenos Aires, Argentina. This workshop was an oriented training and scientific exchange between professionals and technicians who work in medical physics, especially in the areas of diagnostic imaging, nuclear medicine and radiotherapy, with special emphasis on the use of multimodal imaging for radiation treatment, planning as well of quality assurance associates.

  17. A complex method of equipment replacement planning. An advanced plan for the replacement of medical equipment.

    Science.gov (United States)

    Dondelinger, Robert M

    2004-01-01

    This complex method of equipment replacement planning is a methodology; it is a means to an end, a process that focuses on equipment most in need of replacement, rather than the end itself. It uses data available from the maintenance management database, and attempts to quantify those subjective items important [figure: see text] in making equipment replacement decisions. Like the simple method of the last issue, it is a starting point--albeit an advanced starting point--which the user can modify to fit their particular organization, but the complex method leaves room for expansion. It is based on sound logic, documented facts, and is fully defensible during the decision-making process and will serve your organization well as provide a structure for your equipment replacement planning decisions.

  18. Advances in medical diagnostic technology

    CERN Document Server

    Lai, Khin Wee; Mohamad Salim, Maheza Irna; Ong, Sang-Bing; Utama, Nugraha Priya; Myint, Yin Mon; Mohd Noor, Norliza; Supriyanto, Eko

    2014-01-01

    This book provides the most recent findings and knowledge in advanced diagnostics technology, covering a wide spectrum including brain activity analysis, breast and lung cancer detection, echocardiography, computer aided skeletal assessment to mitochondrial biology imaging at the cellular level. The authors explored magneto acoustic approaches and tissue elasticity imaging for the purpose of breast cancer detection. Perspectives in fetal echocardiography from an image processing angle are included. Diagnostic imaging in the field of mitochondrial diseases as well as the use of Computer-Aided System (CAD) are also discussed in the book. This book will be useful for students, lecturers or professional researchers in the field of biomedical sciences and image processing.

  19. Design of portable ultraminiature flow cytometers for medical diagnostics

    Science.gov (United States)

    Leary, James F.

    2018-02-01

    Design of portable microfluidic flow/image cytometry devices for measurements in the field (e.g. initial medical diagnostics) requires careful design in terms of power requirements and weight to allow for realistic portability. True portability with high-throughput microfluidic systems also requires sampling systems without the need for sheath hydrodynamic focusing both to avoid the need for sheath fluid and to enable higher volumes of actual sample, rather than sheath/sample combinations. Weight/power requirements dictate use of super-bright LEDs with top-hat excitation beam architectures and very small silicon photodiodes or nanophotonic sensors that can both be powered by small batteries. Signal-to-noise characteristics can be greatly improved by appropriately pulsing the LED excitation sources and sampling and subtracting noise in between excitation pulses. Microfluidic cytometry also requires judicious use of small sample volumes and appropriate statistical sampling by microfluidic cytometry or imaging for adequate statistical significance to permit real-time (typically in less than 15 minutes) initial medical decisions for patients in the field. This is not something conventional cytometry traditionally worries about, but is very important for development of small, portable microfluidic devices with small-volume throughputs. It also provides a more reasonable alternative to conventional tubes of blood when sampling geriatric and newborn patients for whom a conventional peripheral blood draw can be problematical. Instead one or two drops of blood obtained by pin-prick should be able to provide statistically meaningful results for use in making real-time medical decisions without the need for blood fractionation, which is not realistic in the doctor's office or field.

  20. Improvement of the Russian system of medical care at the site of space crew landing

    Science.gov (United States)

    Rukavishnikov, Ilya; Bogomolov, Valery; Polyakov, Alexey

    The crew members are delivered to ISS and return back to the Earth on the space craft "Soyuz TMA" at present time. The technical means providing the safe landing of space crews are reliable enough. In spite of that the complex of negative factors (long lasting alternating and shock overloads, effects of landing apparatus rotation on vestibular system) affects the crew during landing and can reach the extreme values under the certain conditions. According to this fact there is a possibility of appearance of bodily damages of different weight besides the traditional functional disturbances. The group of search and rescue on the landing site includes the medical specialists appropriately equipped to stop the symptoms of medical contingency (strong vestibule-vegetative reactions, traumas of different weight, etc.) Medical evacuation complex which provides the acceptable conditions for the cosmonauts including the conditions for medical care is delivered to the landing site as well. The long term experience of search and rescue assurance at the landing site have shown that the specialists successfully cope with this task. In some cases it was required to give the medical help which allowed to improve the general condition and physical capacity of crewmembers and provide their evacuation to the places of postflight rehabilitation. At the same time the solution of some of the problems from our point of view could increase the efficacy of medical care for the landing crew. The organization of the training on emergency under the field conditions for medical specialists on the regular basis (not less that once a year) is extremely important. The equipment of medical specialists requires the regular improvement and modernization due to the fast changing medical technologies and standards. Wearable medical sets must provide the first aid performing in accordance to the modern medical requirements. It is also necessary to include in the list of equipment the textbook of

  1. Beyond Diagnostic Accuracy: The Clinical Utility of Diagnostic Tests

    NARCIS (Netherlands)

    Bossuyt, Patrick M. M.; Reitsma, Johannes B.; Linnet, Kristian; Moons, Karel G. M.

    2012-01-01

    Like any other medical technology or intervention, diagnostic tests should be thoroughly evaluated before their introduction into daily practice. Increasingly, decision makers, physicians, and other users of diagnostic tests request more than simple measures of a test's analytical or technical

  2. Data driven approaches for diagnostics and optimization of NPP operation

    International Nuclear Information System (INIS)

    Pliska, J.; Machat, Z.

    2014-01-01

    The efficiency and heat rate is an important indicator of both the health of the power plant equipment and the quality of power plant operation. To achieve this challenges powerful tool is a statistical data processing of large data sets which are stored in data historians. These large data sets contain useful information about process quality and equipment and sensor health. The paper discusses data-driven approaches for model building of main power plant equipment such as condenser, cooling tower and the overall thermal cycle as well using multivariate regression techniques based on so called a regression triplet - data, model and method. Regression models comprise a base for diagnostics and optimization tasks. Diagnostics and optimization tasks are demonstrated on practical cases - diagnostics of main power plant equipment to early identify equipment fault, and optimization task of cooling circuit by cooling water flow control to achieve for a given boundary conditions the highest power output. (authors)

  3. Integration of Diagnostics into Ground Equipment Study. Volume 1

    National Research Council Canada - National Science Library

    Kumara, Soundar; Gautam, N; Hall, Dave; Purao, Sandeep; Garga, Amulya; Grimes, Barney

    2004-01-01

    ...) for Ground Equipment used by the U.S. Marine Corps. The study reviewed the sources of Autonomic Logistics data, the data requirements, the timeliness or required "pull" of such data, its transmission means...

  4. Diagnostic radiology: I

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    This chapter describes the historic development of diagnostic equipment for radiology. The problems associated with fluoroscope design are detailed and the current uses of updated technology, particularly digitization, are considered. Numerous historical photographs are included. 13 refs

  5. Nova target diagnostics control system

    International Nuclear Information System (INIS)

    Severyn, J.R.

    1985-01-01

    During the past year the Nova target diagnostics control system was finished and put in service. The diagnostics loft constructed to the north of the target room provides the environmental conditions required to collect reliable target diagnostic data. These improvements include equipment cooling and isolation of the power source with strict control of instrumentation grounds to eliminate data corruption due to electromagnetic pulses from the laser power-conditioning system or from target implosion effects

  6. Cognitive bias in clinical practice - nurturing healthy skepticism among medical students.

    Science.gov (United States)

    Bhatti, Alysha

    2018-01-01

    Errors in clinical reasoning, known as cognitive biases, are implicated in a significant proportion of diagnostic errors. Despite this knowledge, little emphasis is currently placed on teaching cognitive psychology in the undergraduate medical curriculum. Understanding the origin of these biases and their impact on clinical decision making helps stimulate reflective practice. This article outlines some of the common types of cognitive biases encountered in the clinical setting as well as cognitive debiasing strategies. Medical educators should nurture healthy skepticism among medical students by raising awareness of cognitive biases and equipping them with robust tools to circumvent such biases. This will enable tomorrow's doctors to improve the quality of care delivered, thus optimizing patient outcomes.

  7. Image formation in diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Boer, J.A. den.

    1983-01-01

    This thesis deals with a physical description of the image formation in static radiographic shadow image X-ray equipment and an analysis of the optimization of such systems. For the latter criteria have been developed that take into account all relevant physical phenomena that relate to properties of the image and the radiation exposure of the patient. The discussion of image formation results in a number of relations between the X-ray system parameters on the one hand and properties of the X-ray image on the other. The three principal aspects considered are energy transfer, modulation transfer and noise. (Auth./C.F.)

  8. Collective dose estimation in Portuguese population due to medical exams of diagnostic radiology and nuclear medicine

    International Nuclear Information System (INIS)

    Teles, Pedro; Vaz, Pedro; Paulo, Graciano; Santos, Joana; Pascoal, Ana; Lanca, Isabel; Matela, Nuno; Sousa, Patrick; Carvoeiras, Pedro; Parafita, Rui; Simaozinho, Paula

    2013-01-01

    In order to assess the exposure of the Portuguese population to ionizing radiation due to medical examinations of diagnostic radiology and nuclear medicine, a working group, consisting of 40 institutions, public and private, was created to evaluation the coletive dose in the Portuguese population in 2010. This work was conducted in collaboration with the Dose Datamed European consortium, which aims to assess the exposure of the European population to ionizing radiation due to 20 diagnostic radiology examinations most frequent in Europe (the 'TOP 20') and nuclear medicine examinations. We obtained an average value of collective dose of ≈ 1 mSv/caput, which puts Portugal in the category of countries medium to high exposure to Europe. We hope that this work can be a starting point to bridge the persistent lack of studies in the areas referred to in Portugal, and to enable the characterization periodic exposure of the Portuguese population to ionizing radiation in the context of medical applications

  9. Diagnostic value and safety of medical thoracoscopy in tuberculous pleural effusion.

    Science.gov (United States)

    Wang, Zhen; Xu, Li-Li; Wu, Yan-Bing; Wang, Xiao-Juan; Yang, Yuan; Zhang, Jun; Tong, Zhao-Hui; Shi, Huan-Zhong

    2015-09-01

    Differentiating tuberculous pleural effusion from other lymphocytic pleural effusions is often challenging. This retrospective study aimed to assess the efficacy and safety of medical thoracoscopy in patients with suspected tuberculous pleural effusion. Between July 2005 and June 2014, patients with pleural effusions of unknown etiologies underwent medical thoracoscopy in our institute after less invasive means of diagnosis had failed. Demographic, radiographic, procedural, and histological data of patients with tuberculous pleural effusion were analyzed. During this 9-year study, 333 of 833 patients with pleural effusion were confirmed to have tuberculous pleurisy. Under thoracoscopy, we observed pleural nodules in 69.4%, pleural adhesion in 66.7%, hyperemia in 60.7%, plaque-like lesions in 6.0%, ulceration in 1.5% of patients with tuberculous pleurisy. Pleural biopsy revealed the presence of Mycobacterium tuberculosis in the pleural tissue or/and demonstration of caseating granulomas in 330 (99.1%) patients. No serious adverse events were recorded, and the most common minor complication was transient chest pain (43.2%) from the indwelling chest tube. Our data showed that medical thoracoscopy is a simple procedure with high diagnostic yield and excellent safety for the diagnosis of tuberculous pleural effusion. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Integrating molecular diagnostics into histopathology training: the Belfast model.

    Science.gov (United States)

    Flynn, C; James, J; Maxwell, P; McQuaid, S; Ervine, A; Catherwood, M; Loughrey, M B; McGibben, D; Somerville, J; McManus, D T; Gray, M; Herron, B; Salto-Tellez, M

    2014-07-01

    Molecular medicine is transforming modern clinical practice, from diagnostics to therapeutics. Discoveries in research are being incorporated into the clinical setting with increasing rapidity. This transformation is also deeply changing the way we practise pathology. The great advances in cell and molecular biology which have accelerated our understanding of the pathogenesis of solid tumours have been embraced with variable degrees of enthusiasm by diverse medical professional specialties. While histopathologists have not been prompt to adopt molecular diagnostics to date, the need to incorporate molecular pathology into the training of future histopathologists is imperative. Our goal is to create, within an existing 5-year histopathology training curriculum, the structure for formal substantial teaching of molecular diagnostics. This specialist training has two main goals: (1) to equip future practising histopathologists with basic knowledge of molecular diagnostics and (2) to create the option for those interested in a subspecialty experience in tissue molecular diagnostics to pursue this training. It is our belief that this training will help to maintain in future the role of the pathologist at the centre of patient care as the integrator of clinical, morphological and molecular information. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  11. Evidence of the preferential use of disease prototypes over case exemplars among early year one medical students prior to and following diagnostic training.

    Science.gov (United States)

    Papa, Frank J; Li, Feiming

    2015-12-01

    Two core dual processing theory (DPT) System I constructs (Exemplars and Prototypes) were used to: 1) formulate a training exercise designed to improve diagnostic performance in year one medical students, and 2) explore whether any observed performance improvements were associated with preferential use of exemplars or prototypes. With IRB approval, 117 year one medical students participated in an acute chest pain diagnostic training exercise. A pre- and post-training test containing the same 27 case vignettes was used to determine if the subjects' diagnostic performance improved via training in both exemplars and prototypes. Exemplar and Prototype theory was also used to generate a unique typicality estimate for each case vignette. Because these estimates produce different performance predictions, differences in the subjects' observed performance would make it possible to infer whether subjects were preferentially using Exemplars or Prototypes. Pre- vs. post-training comparison revealed a significant performance improvement; t=14.04, pmid typical vignettes: t=4.94, pleast typical: t=5.16, pmid typical: t=2.94, pleast typical: t=6.64, ptheory than Exemplar theory. DPT is useful in designing and evaluating the utility of new approaches to diagnostic training, and, investigating the cognitive factors driving diagnostic capabilities among early medical students.

  12. Methods for medical device and equipment procurement and prioritization within low- and middle-income countries: findings of a systematic literature review.

    Science.gov (United States)

    Diaconu, Karin; Chen, Yen-Fu; Cummins, Carole; Jimenez Moyao, Gabriela; Manaseki-Holland, Semira; Lilford, Richard

    2017-08-18

    Forty to 70 % of medical devices and equipment in low- and middle-income countries are broken, unused or unfit for purpose; this impairs service delivery to patients and results in lost resources. Undiscerning procurement processes are at the heart of this issue. We conducted a systematic review of the literature to August 2013 with no time or language restrictions to identify what product selection or prioritization methods are recommended or used for medical device and equipment procurement planning within low- and middle-income countries. We explore the factors/evidence-base proposed for consideration within such methods and identify prioritization criteria. We included 217 documents (corresponding to 250 texts) in the narrative synthesis. Of these 111 featured in the meta-summary. We identify experience and needs-based methods used to reach procurement decisions. Equipment costs (including maintenance) and health needs are the dominant issues considered. Extracted data suggest that procurement officials should prioritize devices with low- and middle-income country appropriate technical specifications - i.e. devices and equipment that can be used given available human resources, infrastructure and maintenance capacity. Suboptimal device use is directly linked to incomplete costing and inadequate consideration of maintenance services and user training during procurement planning. Accurate estimation of life-cycle costing and careful consideration of device servicing are of crucial importance.

  13. ITER diagnostics: Maintenance and commissioning in the hot cell test bed

    International Nuclear Information System (INIS)

    Walker, C.I.; Barnsley, R.; Costley, A.E.; Gottfried, R.; Haist, B.; Itami, K.; Kondoh, T.; Loesser, G.D.; Palmer, J.; Sugie, T.; Tesini, A.; Vayakis, G.

    2005-01-01

    In-vessel diagnostic equipment in ITER integrated in six equatorial and 12 upper ports, 16 divertor cassettes and five lower ports is designed to be removed in modules and then repaired, tested and commissioned in the same location at the ITER hot cell. The repair requirements and tests on these components are described along with design features that facilitate repair. The testing establishes the repair strategy, qualifies the refurbishment work and finally checks the mechanical and diagnostic function before the return of the modules. At the hot cell, a dummy port is provided for tests of mechanical and vacuum integrity as well as commissioning of the diagnostic equipment. The scope of the hot cell maintenance and commissioning activities is summarised and an overview of the integration of the diagnostic equipment is given

  14. 浅谈医疗设备管理中的预防性维护%On advantages and disadvantages of preventive maintenance for medical equipments

    Institute of Scientific and Technical Information of China (English)

    张宜江; 焦明阳

    2012-01-01

    目的:医疗设备是医院现代化建设的物质基础,加强医疗设备管理,使医疗设备预防性维护(PM)成为医院现代化管理的一项重要措施.方法:在医院建设中,人才是基础,医疗器械是条件,管理是关键.加强医疗设备管理是医院重点工作之一,在医疗设备管理中维修与保养则是重中之重.结果:做好医疗设备的维护保养对延长仪器寿命、提高诊断准确率起到重要作用.结论:预防性维护是指周期性地对仪器进行一系列科学的维护工作,以确保仪器安全地处于最佳工作状态.%Objective: Hospital medical equipment is the material basis of hospital modernization, and also an important symbol of the modernization. Methods: In hospital construction, talent is the foundation, medical equipment is the condition, management is the key. Strengthen the management of medical equipment is a focal point of the work of the hospital. In the management of medical equipment, repair and maintenance is very important. Results: The maintenance plays an important role in extending equipment life and improving the accuracy of diagnosis. Conclusion: Preventive maintenance is a series of scientific maintenance work for equipments, to ensure that the apparatus securely in the best working condition. This series of maintenance work mainly includes the operating performance test and adjustment, electrical safety testing, cleaning, lubricating, and replacing consumable components.

  15. Diagnostic reasoning strategies and diagnostic success.

    Science.gov (United States)

    Coderre, S; Mandin, H; Harasym, P H; Fick, G H

    2003-08-01

    Cognitive psychology research supports the notion that experts use mental frameworks or "schemes", both to organize knowledge in memory and to solve clinical problems. The central purpose of this study was to determine the relationship between problem-solving strategies and the likelihood of diagnostic success. Think-aloud protocols were collected to determine the diagnostic reasoning used by experts and non-experts when attempting to diagnose clinical presentations in gastroenterology. Using logistic regression analysis, the study found that there is a relationship between diagnostic reasoning strategy and the likelihood of diagnostic success. Compared to hypothetico-deductive reasoning, the odds of diagnostic success were significantly greater when subjects used the diagnostic strategies of pattern recognition and scheme-inductive reasoning. Two other factors emerged as independent determinants of diagnostic success: expertise and clinical presentation. Not surprisingly, experts outperformed novices, while the content area of the clinical cases in each of the four clinical presentations demonstrated varying degrees of difficulty and thus diagnostic success. These findings have significant implications for medical educators. It supports the introduction of "schemes" as a means of enhancing memory organization and improving diagnostic success.

  16. Proposal of dose constraint values to the patient in diagnostic radiology

    International Nuclear Information System (INIS)

    Arranz, L.; Sastre, J.M.; Ferrer, N.; Andres, J.C. De; Guibelalde, E.; Tobarra, B.; Madrid, G.

    1996-01-01

    A dose constraint is the value of an individual dose not to be exceeded in the individual dose distribution considered in an optimization process. The objective of a dose constraints is to set a ceiling to the doses to individual from a source, practice or task which are considered acceptable in the optimization process at the design stage. Implicitly, as C. Zuur states, dose constraints are below the relevant dose limit and usually should be established as local or national levels. Exposures for medical purposes are not subject to dose limits and hence dose constraints were recommended by the ICRP just for occupational and public exposures. However, as an effective tool for optimization for medical exposures, ICRP-60 in paragraph 180 recognizes the value of applying this concept to patient diagnostic radiology with some peculiarities: 'Considerations should be given to the use of dose constraints, or investigation levels, selected by the appropriate professional or regulatory agency, for application in some common diagnostic procedures. They should be applied with flexibility to allow higher cases where indicated by sound clinical judgement.' This paper analyzes retrospectively the dose levels imparted to patient in some common examinations (chest, lumbar spine and mammography) at different optimization stages of different facilities to propose some local constraints for diagnostic examinations. Dose values have been obtained under routine working conditions. Centres included in the survey have been chosen all over Spain, classifying them with particular attention to the following aspects: -Organizational aspects of the diagnostic radiology service, i.e., operational, technical and clinical criteria, as well as quality requirements. - Evaluation and revision of routine medical protocols. -Quality control of the radiological equipment. - Quality criteria for the surveillance of the weekly procedures, with requirements of proper training of die technical staff

  17. Basic concepts and issues: a primer on distribution and sales representative agreements in the medical device and durable medical equipment industries.

    Science.gov (United States)

    Burow, Heiko E; Kolls, Raymond C

    2006-01-01

    Counsel for a manufacturer of medical devices or durable medical equipment must have working knowledge of various legal disciplines to draft contracts with intermediaries (sales representatives and distributors) for the marketing and sale of the manufacturer's products. If the manufacturer wishes to sell its products abroad, counsel must become familiar with the laws and business practices of the target country, and methods of gaining access to the foreign market. This Article gives readers an overview of the applicable legal principles, under U.S. and foreign laws, in the areas of agency, contracts, healthcare regulation, consumer protection, intellectual property protection, and dealer protection. To aid counsel in drafting intermediary agreements, specific contractual terms and issues are explored in depth, including: appointment clauses, performance provisions, provisions concerning pricing and payment, protective clauses (shielding the manufacturer from liability), term and termination provisions, independent contractor clauses, export control clauses, recordkeeping and audit provisions, choice of law clauses, and dispute resolution clauses.

  18. Evaluation of conventional x-ray diagnostic equipment and radiological protection systems of hospitals and clinics installed in Recife city, Brazil; Avaliacao dos equipamentos de raios-X diagnostico convencionais e dos sistemas de protecao radiologica de clinicas e hospitais da cidade de Recife

    Energy Technology Data Exchange (ETDEWEB)

    Passos, Robson Silva

    1999-05-15

    Diagnostic radiology is the main contributor to the man-made exposure of general population. Since Quality Assurance (QA) programs ensure high quality diagnostic images with the lowest possible radiation dose to the patient, it has been recommended that all introduce QA programs for their radiological facilities. Consequently it is important to check the adequacy of equipment operating parameters in diagnostic radiography facilities, to ensure that a high quality of service is delivered. The purpose of this study was to evaluate the operating conditions of diagnostic units installed in Recife, Pernambuco. The study included 31 X-ray units from both public and private diagnostic services. The following parameters were evaluated: coincidence between the luminous and radiation fields; alignment of the radiation beam; agreement between the real and preset values of kVp and exposure time; filtration; half value lower (HVL); luminance of the view box; uniformity of the luminance; illuminance of the environment. The results showed that 20% of the equipment surveyed exhibited discrepancies between the luminous and radiation fields greater than 2% of the source to skin distance. The test of kilovoltage showed that 48% of the units do not fulfill the acceptability criteria, presenting discrepancies higher than {+-} 10% between the measured and preset values. The results of the accuracy of the timer indicated that 81% of the equipment surveyed present a discrepancy greater than {+-} 10% between the time selected in the control panel and actual exposure time.The test of the filtration shown that, in 20% of the equipment, this was inferior to 2,5 mm Al. The test of the luminance of view box shown that 96% of the equipment, shown a luminance lower of 2.000 cd/m{sup 2}. Related to the test of the uniformity of the luminance, 81 % of the equipment shown a variation of the uniformity higher then 10%. The test of the iluminancy of the environment shown that 61 % of the equipment

  19. Exposure parameters in fluoroscopy equipment. Quality control

    International Nuclear Information System (INIS)

    Alonso, M.; Castaneda, M.J.; Matorras, P.; Diaz-Caneja, N.; Gutierrez, I.

    1992-01-01

    Within the quality control program in Diagnostic Radiology currently being undertaken at the 'Marques de Valdecilla' University Hospital, the corresponding specification and procedure prototypes for the control of conventional radioscopy equipment have been elaborated and applied. This paper presents the values proposed in the specifications and those obtained for the following radioscopy equipment parameters: reference kerma, and its reproducibility, kerma linearity, maximum kerma at the skin, and total filtration. The results obtained indicate that the equipment studied could comply with specified requirements if a Maintenance Program were to be implemented in coordination with the Quality Control Program. (author)

  20. Dual Processing Model for Medical Decision-Making: An Extension to Diagnostic Testing.

    Science.gov (United States)

    Tsalatsanis, Athanasios; Hozo, Iztok; Kumar, Ambuj; Djulbegovic, Benjamin

    2015-01-01

    Dual Processing Theories (DPT) assume that human cognition is governed by two distinct types of processes typically referred to as type 1 (intuitive) and type 2 (deliberative). Based on DPT we have derived a Dual Processing Model (DPM) to describe and explain therapeutic medical decision-making. The DPM model indicates that doctors decide to treat when treatment benefits outweigh its harms, which occurs when the probability of the disease is greater than the so called "threshold probability" at which treatment benefits are equal to treatment harms. Here we extend our work to include a wider class of decision problems that involve diagnostic testing. We illustrate applicability of the proposed model in a typical clinical scenario considering the management of a patient with prostate cancer. To that end, we calculate and compare two types of decision-thresholds: one that adheres to expected utility theory (EUT) and the second according to DPM. Our results showed that the decisions to administer a diagnostic test could be better explained using the DPM threshold. This is because such decisions depend on objective evidence of test/treatment benefits and harms as well as type 1 cognition of benefits and harms, which are not considered under EUT. Given that type 1 processes are unique to each decision-maker, this means that the DPM threshold will vary among different individuals. We also showed that when type 1 processes exclusively dominate decisions, ordering a diagnostic test does not affect a decision; the decision is based on the assessment of benefits and harms of treatment. These findings could explain variations in the treatment and diagnostic patterns documented in today's clinical practice.

  1. Dual Processing Model for Medical Decision-Making: An Extension to Diagnostic Testing.

    Directory of Open Access Journals (Sweden)

    Athanasios Tsalatsanis

    Full Text Available Dual Processing Theories (DPT assume that human cognition is governed by two distinct types of processes typically referred to as type 1 (intuitive and type 2 (deliberative. Based on DPT we have derived a Dual Processing Model (DPM to describe and explain therapeutic medical decision-making. The DPM model indicates that doctors decide to treat when treatment benefits outweigh its harms, which occurs when the probability of the disease is greater than the so called "threshold probability" at which treatment benefits are equal to treatment harms. Here we extend our work to include a wider class of decision problems that involve diagnostic testing. We illustrate applicability of the proposed model in a typical clinical scenario considering the management of a patient with prostate cancer. To that end, we calculate and compare two types of decision-thresholds: one that adheres to expected utility theory (EUT and the second according to DPM. Our results showed that the decisions to administer a diagnostic test could be better explained using the DPM threshold. This is because such decisions depend on objective evidence of test/treatment benefits and harms as well as type 1 cognition of benefits and harms, which are not considered under EUT. Given that type 1 processes are unique to each decision-maker, this means that the DPM threshold will vary among different individuals. We also showed that when type 1 processes exclusively dominate decisions, ordering a diagnostic test does not affect a decision; the decision is based on the assessment of benefits and harms of treatment. These findings could explain variations in the treatment and diagnostic patterns documented in today's clinical practice.

  2. The Medical Exposure to Ionizing Radiation and Protection of the Patient in Medical Imaging Procedures for Diagnostic and Therapeutic Purposes (Excluding Radiotherapy) using X-Rays in Israel - Risk - Cost and Benefit

    International Nuclear Information System (INIS)

    Ben-Shlomo, A.

    1998-10-01

    Diagnostic and therapeutic radiology is playing a major role in modern medicine. The utilization of devices emitting ionizing radiation for medical diagnostic and therapeutic purposes is classified into three categories: a. Radiotherapy procedures for the treatment of malignant and benign tumors. b. Nuclear medicine procedures using radiopharmaceuticals that are introduced into the patient's body for diagnostic and therapeutic purposes. c. Diagnostic and therapeutic x-ray imaging procedures. This group includes conventional radiography, conventional fluoroscopy, cardiac catheterization, angiography, CT, mammography, dental, and fluoroscopy operation procedures. A survey was carried out on a sample of three major Israeli hospitals in order to: 1. Determine the status of radiation protection of patients in Israel with regard to the use of x-rays in medical imaging and interventional radiology. 2. Assess the extent of exposure of the population to medical x-rays, and assess the collective risk in Israel in this relation (based on Icr-60). 3. Carry out a cost-benefit optimization procedure related to the means that should be used to reduce the exposure of Israeli patients under x-ray procedures. 4. Establish a of practical recommendations to reduce the x-ray radiation exposure of patients and to increase the image quality. 5. Establish a number of basic rules to be utilized by health policy makers in Israel

  3. The Medical Exposure to Ionizing Radiation and Protection of the Patient in Medical Imaging Procedures for Diagnostic and Therapeutic Purposes (Excluding Radiotherapy) using X-Rays in Israel - Risk - Cost and Benefit

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Shlomo, A

    1998-10-01

    Diagnostic and therapeutic radiology is playing a major role in modern medicine. The utilization of devices emitting ionizing radiation for medical diagnostic and therapeutic purposes is classified into three categories: a. Radiotherapy procedures for the treatment of malignant and benign tumors. b. Nuclear medicine procedures using radiopharmaceuticals that are introduced into the patient's body for diagnostic and therapeutic purposes. c. Diagnostic and therapeutic x-ray imaging procedures. This group includes conventional radiography, conventional fluoroscopy, cardiac catheterization, angiography, CT, mammography, dental, and fluoroscopy operation procedures. A survey was carried out on a sample of three major Israeli hospitals in order to: 1. Determine the status of radiation protection of patients in Israel with regard to the use of x-rays in medical imaging and interventional radiology. 2. Assess the extent of exposure of the population to medical x-rays, and assess the collective risk in Israel in this relation (based on Icr-60). 3. Carry out a cost-benefit optimization procedure related to the means that should be used to reduce the exposure of Israeli patients under x-ray procedures. 4. Establish a of practical recommendations to reduce the x-ray radiation exposure of patients and to increase the image quality. 5. Establish a number of basic rules to be utilized by health policy makers in Israel.

  4. Medical Issues: Orthopedics

    Science.gov (United States)

    ... Information Packets Equipment Pool Living With SMA Medical Issues Palliative Breathing Orthopedics Nutrition Equipment Daily Life At ... curesma.org > support & care > living with sma > medical issues > orthopedics Orthopedics In SMA, muscle weakness can cause ...

  5. Medical Issues: Breathing

    Science.gov (United States)

    ... Information Packets Equipment Pool Living With SMA Medical Issues Palliative Breathing Orthopedics Nutrition Equipment Daily Life At ... curesma.org > support & care > living with sma > medical issues > breathing Breathing Breathing problems are the most common ...

  6. Exposure of Medical Staff during Interventional Procedures

    International Nuclear Information System (INIS)

    Osvay, M.; Turak, O.

    2013-01-01

    The medical staff during interventional procedures receives significant doses on their hands, or parts of their body not covered with protective shielding equipment, as they are close to X-rays field. It can be stated, that interventional radiology and cardiology have one of the highest doses among the X-ray diagnostic procedures. The radiologist use X-ray machine directly in the interventional procedures. The occupational dose is measured only by one Kodak film badge worn under the lead apron for the estimation of the effective dose in Hungary. Our lecture presents the results of dose measurements on eye lens, hands, knees using LiF thermoluminescent dosemeters on the medical staff of two Hungarian hospitals. Results suggest that wearing only one film badge (or other dosemeter system) under the lead apron does not provide proper information on the real occupational dose of medical staff.(author)

  7. Assessment of technical equipment supply in healthcare institutions: example of Almaty

    Directory of Open Access Journals (Sweden)

    Kuralbai K Kurakbayev

    2014-01-01

    Full Text Available Background: The share of healthcare-related expenditure in the Gross Domestic Product of Kazakhstan is relatively small, and it is strategically important to restructure budgetary expenses in favor of healthcare with simultaneous redistribution of resources in accordance with changing demands and prioritization of high-quality medical care. The aim of this study was to analyze resource provision to healthcare organizations in Kazakhstan and its structure and level assessment. Materials and Methods: The study is based on a comparative assessment of technical and technological equipment of medical institutions in Almaty, Kazakhstan. We analyzed the scope and structure of the financial component of the resource base in Almaty. We carried out information processing and analysis methods, content analysis, mathematical treatment, as well as conducted case studies. Also, we held opinion poll among medical staff (specialists, managerial staff (n = 300 P for trend < 0.001 and patients (n = 210 P for trend < 0.001. Results: About 18.8% of patients do not receive medical care because of defects of the equipment, whereas 19.9% of patients claim that the reason of refusal of the provision of medical services is an equipment overload. Conclusion: Most of the respondents referred to on poor technical equipment, mismatch with the world standards of performance and competitiveness. Lack of advanced medical technology, inadequate financing, insufficient supply of domestic medical equipment, and inadequate procurement by tender were also noted. The obtained data point to the need for optimization and upgrading medical equipment at various levels of healthcare.

  8. [Medical equipment product lines in basic pharmacies].

    Science.gov (United States)

    Macesková, B; Lipská, J

    2003-07-01

    Medical appliances dispensed in basic type pharmacies for cash or vouchers for medical or orthopedic appliances require expertise of pharmacists and laboratory assistants concerning the assortment, payment, construction of prices, conditions for prescription, ordering, properties, and functions of individual appliances. Using the method of frequency analysis, the analysis of data from five pharmacies within a period of three months (more than 17,000 records) revealed how individual subgroups of medical appliances and their concrete items are represented in both types of dispensation. The method of the semistructured questionnaire (10 respondents) was used to find what problems are encountered in dispensation, and which medical appliances and their subgroups are the sources of the problems. The respondents regard the contemporary level of knowledge concerning medical appliances gained in pregradual studies as insufficient.

  9. Evaluation of the conditions of operation of X-ray equipment as regards the coincidence between light field, radiation field and the central ray alignment in radiology services of the Recife, Brazil

    International Nuclear Information System (INIS)

    Oliveira, Claudia F.M.; Silva, Iran J.O.; Lopes Filho, Ferdinand J.; Morais, Carolinne S.; Junior, Claudio L.R.

    2014-01-01

    This paper aims at considering the need for constant evaluation of diagnostic radiology equipment and the fact that this issue be part of the radiology technologist's tasks, develop skills in radiology technologist through applying quality control tests, as regards the assessment of coincidence between the light field and the radiation field and the alignment of the radiation beam of medical X-ray equipment in radiology services in the city of Recife. For the tests, the procedures by national protocols of Quality Control Tests were adopted - QCT and the Medical Radiodiagnosis Manual. The instruments used to check the alignment of the central ray was an acrylic cylinder with steel balls of 0.8 mm diameter located in the upper and lower base separated by a distance of 15 cm, a chassis loaded with film, tape and level bubble. The results show that the tested devices are in good condition for diagnostic radiology, with regard to both the radiation field to be exposed as well as the image quality for a more accurate diagnosis, which guarantees the individual radiological protection

  10. Virtual reality aided visualization of fluid flow simulations with application in medical education and diagnostics.

    Science.gov (United States)

    Djukic, Tijana; Mandic, Vesna; Filipovic, Nenad

    2013-12-01

    Medical education, training and preoperative diagnostics can be drastically improved with advanced technologies, such as virtual reality. The method proposed in this paper enables medical doctors and students to visualize and manipulate three-dimensional models created from CT or MRI scans, and also to analyze the results of fluid flow simulations. Simulation of fluid flow using the finite element method is performed, in order to compute the shear stress on the artery walls. The simulation of motion through the artery is also enabled. The virtual reality system proposed here could shorten the length of training programs and make the education process more effective. © 2013 Published by Elsevier Ltd.

  11. Magnetic resonance imaging and spectroscopy- emerging trends in medical diagnostics and therapy

    International Nuclear Information System (INIS)

    Deshmukh, Sudha

    1997-01-01

    A dramatic acceleration in the application of magnetic resonance techniques in the field of medical sciences has been witnessed over the past decade. Magnetic Resonance Imaging (MRI) has been called the most significant development since the discovery of x-rays. As a method of visualizing cross-sectional anatomy, MRI is without peer. MRI images can now provide in-vivo anatomical details that were earlier available only with invasive procedures. Yet, despite its extraordinary potential, MRI has had limited success, if any, in tissue characterization using the three image parameters T 1 , T 2 and proton density ρ. MR spectroscopy has however bridged this gap to a large extent and opened up the possibility of studying in vivo chemistry. In the present article an attempt has been made to give a brief account of the application of magnetic resonance imaging and spectroscopy in medical diagnostics and therapy. The basic principles pertaining to MRI and MRS are also discussed in brief. (author)

  12. A Diagnostic Ultrasound Imaging System

    International Nuclear Information System (INIS)

    Lee, Seong Woo

    1999-01-01

    The ability to see the internal organs of the human body in a noninvasive way is a powerful diagnostic tool of modern medicine. Among these imaging modalities such as X-ray, MRI, and ultrasound. MRI and ultrasound are presenting much less risk of undesirable damage of both patient and examiner. In fact, no deleterious effects have been reported as a result of clinical examination by using MRI and ultrasound diagnostic equipment. As a result, their market volume has been rapidly increased. MRI has a good resolution. but there are a few disadvantages such as high price. non-real-time imaging capability. and expensive diagnostic cost. On the other hand, the ultrasound imaging system has inherently poor resolution as compared with X-ray and MRI. In spite of its poor resolution, the ultrasound diagnostic equipment is lower in price and has an ability of real-time imaging as compared with the others. As a result, the ultrasound imaging system has become general and essential modality for imaging the internal organs of human body. In this review various researches and developments to enhance the resolution of the ultrasound images are explained and future trends of the ultrasound imaging technology are described

  13. 47 CFR 18.203 - Equipment authorization.

    Science.gov (United States)

    2010-10-01

    ... information already on file with the Commission. (2) A technical report pursuant to §§ 18.207 and 18.311. (b... 47 Telecommunication 1 2010-10-01 2010-10-01 false Equipment authorization. 18.203 Section 18.203 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL INDUSTRIAL, SCIENTIFIC, AND MEDICAL EQUIPMENT...

  14. EXPERIENCE IN DEVELOPMENT MEDICAL KITS FOR MEDICAL SERVICES OF THE RUSSIAN FEDERATION ARMED FORCES

    OpenAIRE

    E. O. Rodionov; Yu. V. Miroshnichenko; V. N. Kononov; A. V. Tikhonov; I. V. Klochkova

    2016-01-01

    Introduction. The development of modern, complete-standard issue equipment for the Armed Forces Medical Service is an urgent organizational and management task. First aid kits, medical bags, sets of medical equipment, medical kits and packing existed until recently; no longer meet modern requirements for a number of objective reasons. The aim of the study was the formation of programs of development of modern samples of complete-standard-issue equipment. Materials and methods. The study was c...

  15. Medical program in radiation protection from the Argentine Nuclear Regulatory Authority

    International Nuclear Information System (INIS)

    Perez, M. R.; Gisone, P.; Di Trano, J.L.; Dubner, D.L.; Michelin, S.C.

    1998-01-01

    This program is carried out by the Radio pathology Laboratory, belonging to the Nuclear Regulatory Authority. The program includes the following aspects: 1) planning and organization of medical response in radiological emergencies. A three-level system of medical assistance has been developed considering: a- determination of each level of care and their potential roles; b- choice of medical facilities for medical assistance; c- preparedness for medical response (equipment s, logistic support, human resources, training). 2) scientific research activities related to radio pathology subjects: a- hematological indicators in radioinduced aplasia; b- biological and biophysical dosimeters; c- radiation effects on the developing brain. 3) edition of practical guidelines for diagnostic and treatment: a- external and internal radioactive contamination; b- acute radiation syndrome; c- radiological burns. 4) medical advising in radioprotection (risk assessment in radiation workers, medical exposures, potential effects of prenatal irradiation). 5) international interactions: activities related with the constitution of a Latin American radio pathology network, linkage with international reference centers. (author) [es

  16. Diagnostic x-ray in use in federal medical centre, case study Makurdi metropolis

    International Nuclear Information System (INIS)

    Onoja, R.A.; Fiase, J.O.

    2009-01-01

    Every year more than two thousand patients go for routine medical check-up at the Federal Medical Centre using diagnostic x-rays. This paper is based on a study to determine the entrance surface doses per radiograph of 108 patients that had diagnostic examinations at the Federal Medical Centre Makurdi. The examinations considered in this study are chest x-ray examinations, abdomen, skull and other extremities, for both adults and children. The results show that the mean entrance surface doses of PA chest x-ray for female range between 237-275μGy, for male is between 1183-297μGy, and for children range between 47-237μGy. The AP chest x-ray for female range between 1943-3440μGy, for male is between 1583-3484μGy and for children it ranges between 177-451μGy. The PA examination of the skull for adult female ranged between 117-787μGy, for male it ranged between 117-532μGy and children from 472-948μGy. Also for the AP examination for skull the adult female mean entrance surface doses range from 129-798μGy, for the male it range from 145-178μGy and for children 138-650μGy. The AP abdomen for adult female produces a mean entrance surface doses range between 620-682μGy, for the male is between 105-930μGy, and children it range between 144-398μGy. In the case of extremities AP examination are between the range of 173-468μGy for adult female, 300-595μGy for adult male and between 254-887μGy for the children. In the case of extremities PA examination mean entrance surface doses are between the range of 145-517μGy for adult female, 363-517μGy for adult male and between 130-566μGy for the children. The data shows that the entrance surface doses due to the x-ray examination for adult and children are within the ICRP guidance levels. These guidance levels of dose for diagnostic radiography for a typical adult patient are 10 mGy for AP abdomen, 0.4 mGy PA chest, 7 mGy for AP chest and 5 mGy for PA skull

  17. Regulation EM-GT-7. Quality control of the radiography equipment

    International Nuclear Information System (INIS)

    2015-01-01

    The purpose of this document is to provide practical guidance of technical procedures for carrying out quality control in X-ray equipment. This guide is applicable to general purpose radiography equipment, although some of the procedures may be applied to other types of diagnostic imaging equipment. The tests described require the appointed instrumentation and some of these can be implemented in the radiodiagnostic given the simplicity of them and others require special equipment and can be performed by external specialized groups to these units.

  18. Chief objectives of the development of X-ray equipment engineering in Russia

    International Nuclear Information System (INIS)

    Blinov, N.N.; Varshavskij, Yu.V.; Zelikman, M.I.

    1997-01-01

    Based on the world tendencies in the development of X-ray diagnostic instruments the main problems int he development of domestic X-ray diagnostic equipment engineering are analyzed. Variant of basic equipment for modern X-ray room for digital biomedical radiography is proposed. Tendencies int he instrumentation of X-ray diagnosis are the following ones: X-ray computerized tomograph creation, development of telecontrolled X-ray computerized. complexes for biomedical X-ray complexes for digital biomedical radiography, automation of the film development

  19. CIT diagnostic computer interface studies

    International Nuclear Information System (INIS)

    Rauch, W.; Hayes, S.; Lowrance, J.; Oliaro, G.; Sauthoff, N.; Sichta, P.; Stark, W.

    1987-01-01

    This paper presents the on-going work performed in proposing instrumentation equipment and communications networks for the Diagnostic Data Acquisition and Diagnostic Instrumentation and Control System for the Compact Ignition Torus (CIT), which will begin operation in 1993. Consideration is given to the system criteria and requirements and their influence on the appropriate application of instrumentation and communication technologies to the system. This paper concentrates on the investigation of the bus communication technologies as they apply to the CIT data acquisition system. It compares CAMAC, VME, and FASTBUS as standards for data acquisition. The paper describes the connectivity between VAX equipment and CAMAC and VME instrumentation systems. Instrumentation and communication functionality and performance levels are presented as factors important to the overall data acquisition system performance

  20. An analysis of cancer death risk among medical diagnostic X-ray workers in China, 1950-1995

    International Nuclear Information System (INIS)

    Zhao Yongcheng; Wang Jixian; Zhang Wei; Li Benxiao; Fan Tiqiang; Zhang Jingyuan

    2002-01-01

    Objective: To investigate effects of occupational radiation exposure on cancer death among medical diagnostic X-ray workers. Methods: A cohort study on medical diagnostic X-ray workers and non-X-ray medical workers was carried out and a risk analysis of cancer death between 1950 and 1995 was conducted with the O/E system. Results: A significant enhancement in cancer death risk for X-ray workers was found, especially those engaged in X-ray work in early calendar years. The overall cancer RR was 1.26, (95 % CI: 1.14 - 1.38), for leukemia it was 2.48, (95% CI: 1.68-3.51 ); for esophagus cancer, 3.18, (95% CI: 2.02 -4.77); for liver cancer, 1.54, (95 % CI: 1.27 - 1.86); and for bone cancer, 2.48, (95 % CI: 1.00 - 5.40). In the late calendar year cohort a significant enhancement of cancer death was seen only in esophagus cancer (RR = 4.19, 95 % CI: 1.80 - 8.25) and lung cancer (RR = 1.60, 95% CI:1.10-2.25). Conclusion: Long-term occupational X-ray irradiation can enhance the risk of cancer death when the cumulative dose reached a certain level. The significant enhancement of cancer death for leukemia and some solid cancers may be related to the occupational exposure to X-rays

  1. The evaluation of the irradiation of medical team in critical X-ray diagnostic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Markovic, S; Pavlovic, R [Inst. of Nuclear Science Vinca, Belgrade (Yugoslavia). Radiation and Environmental Protection Lab.; Boreli, F [Fac. of Electrical Engineering, Belgrade (Yugoslavia)

    1996-12-31

    A good realized assessment of the irradiation for any exposed group of population serves as the base for the radiation protection measures (emergency radiation preparedness, radiation protection optimization etc.). This is especially important, by the radiation protection point of view, in contrast X-ray diagnostic techniques - angiographies. This paper presents the way for the realization of the medical team irradiation assessment, based on originally derived simple equations for the scattered radiation field around patient. (author) 1 fig., 3 figs.

  2. 21 CFR 866.4830 - Rocket immunoelectro-phoresis equipment.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents... equipment for clinical use is a device used to perform a specific test on proteins by using a procedure...

  3. Use of antihypertensive medications and diagnostic tests among privately insured adolescents and young adults with primary versus secondary hypertension.

    Science.gov (United States)

    Yoon, Esther Y; Cohn, Lisa; Freed, Gary; Rocchini, Albert; Kershaw, David; Ascione, Frank; Clark, Sarah

    2014-07-01

    To compare the use of antihypertensive medications and diagnostic tests among adolescents and young adults with primary versus secondary hypertension. We conducted retrospective cohort analysis of claims data for adolescents and young adults (12-21 years of age) with ≥3 years of insurance coverage (≥11 months/year) in a large private managed care plan during 2003-2009 with diagnosis of primary hypertension or secondary hypertension. We examined their use of antihypertensive medications and identified demographic characteristics and the presence of obesity-related comorbidities. For the subset receiving antihypertensive medications, we examined their diagnostic test use (echocardiograms, renal ultrasounds, and electrocardiograms). The study sample included 1,232 adolescents and young adults; 84% had primary hypertension and 16% had secondary hypertension. The overall prevalence rate of hypertension was 2.6%. One quarter (28%) with primary hypertension had one or more antihypertensive medications, whereas 65% with secondary hypertension had one or more antihypertensive medications. Leading prescribers of antihypertensives for subjects with primary hypertension were primary care physicians (80%), whereas antihypertensive medications were equally prescribed by primary care physicians (43%) and sub-specialists (37%) for subjects with secondary hypertension. The predominant hypertension diagnosis among adolescents and young adults is primary hypertension. Antihypertensive medication use was higher among those with secondary hypertension compared with those with primary hypertension. Further study is needed to determine treatment effectiveness and patient outcomes associated with differential treatment patterns used for adolescents and young adults with primary versus secondary hypertension. Copyright © 2014 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  4. Equipment concept design and development plans for microgravity science and applications research on space station: Combustion tunnel, laser diagnostic system, advanced modular furnace, integrated electronics laboratory

    Science.gov (United States)

    Uhran, M. L.; Youngblood, W. W.; Georgekutty, T.; Fiske, M. R.; Wear, W. O.

    1986-01-01

    Taking advantage of the microgravity environment of space NASA has initiated the preliminary design of a permanently manned space station that will support technological advances in process science and stimulate the development of new and improved materials having applications across the commercial spectrum. Previous studies have been performed to define from the researcher's perspective, the requirements for laboratory equipment to accommodate microgravity experiments on the space station. Functional requirements for the identified experimental apparatus and support equipment were determined. From these hardware requirements, several items were selected for concept designs and subsequent formulation of development plans. This report documents the concept designs and development plans for two items of experiment apparatus - the Combustion Tunnel and the Advanced Modular Furnace, and two items of support equipment the Laser Diagnostic System and the Integrated Electronics Laboratory. For each concept design, key technology developments were identified that are required to enable or enhance the development of the respective hardware.

  5. High precision instrumentation for measuring the true exposure time in diagnostic X-ray examinations

    International Nuclear Information System (INIS)

    Silva, Danubia B.; Santos, Marcus A.P.; Barros, Fabio R.; Santos, Luiz A.P.

    2013-01-01

    One of the most important physical quantities to be evaluated in diagnostic radiology is the radiation exposure time experimented by the patient during the X-ray examination. IAEA and WHO organizations have suggested that any country must create a quality surveillance program to verify if each type of ionizing radiation equipment used in the hospitals and medical clinics are in conformity with the accepted uncertainties following the international standards. The purpose of this work is to present a new high precision methodology for measuring true exposure time in diagnostic X-ray examinations: pulsed, continuous or digital one. An electronic system named CronoX, which will be soon registered at the Brazilian Patent Office (INPI), is the equipment that provides such a high precision measurement. The principle of measurement is based on the electrical signal captured by a sensor that enters in a regeneration amplifier to transform it in a digital signal, which is treated by a microprocessor (uP). The signal treatment results in a two measured times: 1) T rx , the true X-ray exposure time; 2) T nx , the time in which the X-ray machine is repeatedly cut off during the pulsed irradiation and there is no delivery dose to the patient. Conventional Polymat X-ray equipment and dental X-ray machines were used to generate X-ray photons and take the measurements with the electronic systems. The results show that such a high precision instrumentation displays the true exposure time in diagnostic X-ray examinations and indicates a new method to be purposed for the quality surveillance programs in radiology. (author)

  6. Prototyping low-cost and flexible vehicle diagnostic systems

    Directory of Open Access Journals (Sweden)

    Marisol GARCÍA-VALLS

    2016-12-01

    Full Text Available Diagnostic systems are software and hardware-based equipment that interoperate with an external monitored system. Traditionally, they have been expensive equipment running test algorithms to monitor physical properties of, e.g., vehicles, or civil infrastructure equipment, among others. As computer hardware is increasingly powerful (whereas its cost and size is decreasing and communication software becomes easier to program and more run-time efficient, new scenarios are enabled that yield to lower cost monitoring solutions. This paper presents a low cost approach towards the development of a diagnostic systems relying on a modular component-based approach and running on a resource limited embedded computer. Results on a prototype implementation are shown that validate the presented design, its flexibility, performance, and communication latency.

  7. Estimation of identification limit for a small-type OSL dosimeter on the medical images by measurement of X-ray spectra

    OpenAIRE

    Takegami, Kazuki ; Hayashi, Hiroaki; Okino, Hiroki; Kimoto, Natsumi ; Maehata, Itsumi ; Kanazawa, Yuki ; Okazaki, Tohru ; Hashizume, Takuya ; Kobayashi, Ikuo 

    2016-01-01

    Our aim in this study is to derive an identification limit on a dosimeter for not disturbing a medical image when patients wear a small-type optically stimulated luminescence (OSL) dosimeter on their bodies during X-ray diagnostic imaging. For evaluation of the detection limit based on an analysis of X-ray spectra, we propose a new quantitative identification method. We performed experiments for which we used diagnostic X-ray equipment, a soft-tissue-equivalent phantom (1–20 cm), and a CdTe X...

  8. Value of MRI in radiology. No MRI training in other special medical fields. A joint statement by the DRG and BVDRN

    International Nuclear Information System (INIS)

    Wolf, K.J.; Fischer, J.

    1997-01-01

    Applications of MRI are restricted to the special field of diagnostic radiology, also comprising neuroradiology and pediatric radiology, and this is how it should be. This is the unanimous opinion of the medical self-administration bodies as well as of the supervisory bodies, declared with the coming into force of the WO of 1992. Any spreading of applications to other special medical fields will jeopardize the existence and development of diagnostic radiology. Only its being exclusively applied by diagnostic radiology experts will guarantee and maintain the high quality standards and economic efficiency meanwhile achieved with MRI. The demand for diagnostic MRI examinations is met by the currently available equipment at radiological specialists' practices. The Medical Associations of the Laender Baden-Wuerttemberg, Schleswig-Holstein, Saarland, and Westfalen-Lippe, other than the Bavarian Association, declared that the method should not be opened up for application by orthopedic specialists. The Federal Medical Association is called upon to use its competences as a recommending body in order to make this point clear in a general statement, recommending that MRI applications should be restricted to experts in the field of diagnostic radiology. Another good reason is warranty of equal conditions throughout Germany. There are no facts or reasons that would recommend a softening of current conditions by allowing deviating practice at Laender level. (Orig./AJ) [de

  9. Solid targets and irradiation facilities for production of diagnostic and therapeutic radionuclides at the Debrecen cyclotron

    International Nuclear Information System (INIS)

    Tarkanyi, F.; Ando, L.; Szucs, Z.; Mahunka, I.; Kovacs, Z.

    2000-01-01

    The MGC-20E (NIIEFA, Leningrad, USSR) variable energy compact cyclotron (k=20) was installed in ATOMKI (Debrecen, Hungary) in 1985. Protons, deuterons, 3 He- and α-particles can be accelerated with currents up to 300 μA for internal irradiation and up to 50 μA for external beams. The establishment of the Cyclotron Laboratory was partly supported by the International Atomic Energy Agency. The application of the cyclotron is multipurpose: basic nuclear research, application of activation technique for analytical and wear studies, application of intense fast neutron source for agro-biological, bio-medical application and for radiation damage test of electronic components, and finally radioisotope production for medical diagnostics and for other scientific and applied fields. The cyclotron laboratory has six target rooms, a radiochemistry laboratory and a medical unit equipped with PET

  10. Control and diagnostics of technical state of main electro technical and thermal equipment of NPP, TPS and HPS on the basis of thermovision technologies

    International Nuclear Information System (INIS)

    Banduryan, B.B.; Fedorenko, G.M.; Ostapchuk, L.B.; Saratov, V.O.

    2006-01-01

    The opportunity of using of thermovision technologies for detection of defects NPP, TPS and HPS electro technical and power equipment is shown. The results of thermovision monitoring of a turbine generator stator technical state are represented. The method for thermovision control of a technical state of a electrical machines and apparatus construction elements, for which the patent of Ukraine have been obtained, is described. he verification of the offered expedient thermovision control and diagnostics at 'Elektrovazhmash' factory was carried out

  11. X-ray diagnostics in non-specialized conditions

    International Nuclear Information System (INIS)

    Vasil’yev, A Y; Lyubimenko, V A; Potrakhov, Y N; Potrakhov, N N; Bessonov, V B; Klonov, V V; Larionov, I A; Gryaznov, A Y; Zhamova, K K

    2017-01-01

    The results of research in the development of X-ray diagnostic equipment in non-specialized conditions are described. The design of the first domestic digital X-ray diagnostic complex for neonatology in portable design is presented. Examples of X-ray images obtained “at home” from a patient are given. (paper)

  12. Investigation of radiation protection of medical staff performing medical diagnostic examinations by using PET/CT technique

    International Nuclear Information System (INIS)

    Wrzesień, Małgorzata; Napolska, Katarzyna

    2015-01-01

    Positron emission tomography (PET) is now one of the most important methods in the diagnosis of cancer diseases. Due to the rapid growth of PET/CT centres in Poland in less than a decade, radiation protection and, consequently, the assessment of worker exposure to ionising radiation, emitted mainly by the isotope 18 F, have become essential issues. The main aim of the study was to analyse the doses received by workers employed in the Medical Diagnostic Centre. The analysis comprises a physicist, three nurses, three physicians, three technicians, as well as two administrative staff employees. High-sensitivity thermoluminescent detectors (TLDs) were used to measure the doses for medical staff. The personnel was classified into categories, among them employees having direct contact with the ‘source of radiation’— 18 FDG. The TLDs were placed on the fingertips of both hands and they were also attached at the level of eye lenses, thyroid and gonads depending on the assigned category. The highest dose of radiation was observed during the administration of the 18 FDG to the patients. In the case of the physicist, the highest dose was recorded during preparation of the radiopharmaceutical— 18 FDG. The body parts most exposed to ionizing radiation are the fingertips of the thumb, index and middle finger. (paper)

  13. Investigation of radiation protection of medical staff performing medical diagnostic examinations by using PET/CT technique.

    Science.gov (United States)

    Wrzesień, Małgorzata; Napolska, Katarzyna

    2015-03-01

    Positron emission tomography (PET) is now one of the most important methods in the diagnosis of cancer diseases. Due to the rapid growth of PET/CT centres in Poland in less than a decade, radiation protection and, consequently, the assessment of worker exposure to ionising radiation, emitted mainly by the isotope (18)F, have become essential issues. The main aim of the study was to analyse the doses received by workers employed in the Medical Diagnostic Centre. The analysis comprises a physicist, three nurses, three physicians, three technicians, as well as two administrative staff employees. High-sensitivity thermoluminescent detectors (TLDs) were used to measure the doses for medical staff. The personnel was classified into categories, among them employees having direct contact with the 'source of radiation'-(18)FDG. The TLDs were placed on the fingertips of both hands and they were also attached at the level of eye lenses, thyroid and gonads depending on the assigned category. The highest dose of radiation was observed during the administration of the (18)FDG to the patients. In the case of the physicist, the highest dose was recorded during preparation of the radiopharmaceutical-(18)FDG. The body parts most exposed to ionizing radiation are the fingertips of the thumb, index and middle finger.

  14. Cost Benefit Optimization of the Israeli Medical Diagnostic X-Ray Exposure

    International Nuclear Information System (INIS)

    Ben-Shlomo, A.; Shlesinger, T.; Shani, G.; Kushilevsky, A.

    1999-01-01

    Diagnostic and therapeutic radiology is playing a major role in modern medicine. A preliminary survey was carried out during 1997 on 3 major Israeli hospitals in order to assess the extent of exposure of the population to medical x-rays (1). The survey has found that the annual collective dose of the Israeli population to x-ray medical imaging procedures (excluding radio-therapy) is about 7,500 Man-Sv. The results of the survey were analyzed in order to. 1. Carry out a cost-benefit optimization procedure related to the means that should be used to reduce the exposure of the Israeli patients under x-ray procedures. 2. Establish a set of practical recommendations to reduce the x-ray radiation exposure of patients and to increase the image quality. . Establish a number of basic rules to be utilized by health policy makers in Israel. Based on the ICRP-60 linear model risk assessments (2), the extent of the annual risk arising A.om the 7,500 Man-Sv medical x-ray collective dose in Israel has been found to be the potential addition of 567 cancer cases per year, 244 of which to be fatal, and a potential additional birth of 3-4 children with severe genetic damage per year. This assessment take into account the differential risk and the collective dose according to the age distribution in the Israeli exposed population, and excludes patients with chronic diseases

  15. Radiological safety status and quality assurance audit of medical X-ray diagnostic installations in India.

    Science.gov (United States)

    Sonawane, A U; Singh, Meghraj; Sunil Kumar, J V K; Kulkarni, Arti; Shirva, V K; Pradhan, A S

    2010-10-01

    We conducted a radiological safety and quality assurance (QA) audit of 118 medical X-ray diagnostic machines installed in 45 major hospitals in India. The main objective of the audit was to verify compliance with the regulatory requirements stipulated by the national regulatory body. The audit mainly covered accuracy check of accelerating potential (kVp), linearity of tube current (mA station) and timer, congruence of radiation and optical field, and total filtration; in addition, we also reviewed medical X-ray diagnostic installations with reference to room layout of X-ray machines and conduct of radiological protection survey. A QA kit consisting of a kVp Test-O-Meter (ToM) (Model RAD/FLU-9001), dose Test-O-Meter (ToM) (Model 6001), ionization chamber-based radiation survey meter model Gun Monitor and other standard accessories were used for the required measurements. The important areas where there was noncompliance with the national safety code were: inaccuracy of kVp calibration (23%), lack of congruence of radiation and optical field (23%), nonlinearity of mA station (16%) and timer (9%), improper collimator/diaphragm (19.6%), faulty adjustor knob for alignment of field size (4%), nonavailability of warning light (red light) at the entrance of the X-ray room (29%), and use of mobile protective barriers without lead glass viewing window (14%). The present study on the radiological safety status of diagnostic X-ray installations may be a reasonably good representation of the situation in the country as a whole. The study contributes significantly to the improvement of radiological safety by the way of the steps already taken and by providing a vital feed back to the national regulatory body.

  16. Raman spectroscopy for medical diagnostics--From in-vitro biofluid assays to in-vivo cancer detection.

    Science.gov (United States)

    Kong, Kenny; Kendall, Catherine; Stone, Nicholas; Notingher, Ioan

    2015-07-15

    Raman spectroscopy is an optical technique based on inelastic scattering of light by vibrating molecules and can provide chemical fingerprints of cells, tissues or biofluids. The high chemical specificity, minimal or lack of sample preparation and the ability to use advanced optical technologies in the visible or near-infrared spectral range (lasers, microscopes, fibre-optics) have recently led to an increase in medical diagnostic applications of Raman spectroscopy. The key hypothesis underpinning this field is that molecular changes in cells, tissues or biofluids, that are either the cause or the effect of diseases, can be detected and quantified by Raman spectroscopy. Furthermore, multivariate calibration and classification models based on Raman spectra can be developed on large "training" datasets and used subsequently on samples from new patients to obtain quantitative and objective diagnosis. Historically, spontaneous Raman spectroscopy has been known as a low signal technique requiring relatively long acquisition times. Nevertheless, new strategies have been developed recently to overcome these issues: non-linear optical effects and metallic nanoparticles can be used to enhance the Raman signals, optimised fibre-optic Raman probes can be used for real-time in-vivo single-point measurements, while multimodal integration with other optical techniques can guide the Raman measurements to increase the acquisition speed and spatial accuracy of diagnosis. These recent efforts have advanced Raman spectroscopy to the point where the diagnostic accuracy and speed are compatible with clinical use. This paper reviews the main Raman spectroscopy techniques used in medical diagnostics and provides an overview of various applications. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  17. Radiological safety status and quality assurance audit of medical X-ray diagnostic installations in India

    International Nuclear Information System (INIS)

    Sonawane, A.U.; Singh, Meghraj; Sunil Kumar, J.V.K.; Kulkarni, Arti; Shirva, V.K.; Pradhan, A.S.

    2010-01-01

    We conducted a radiological safety and quality assurance (QA) audit of 118 medical X-ray diagnostic machines installed in 45 major hospitals in India. The main objective of the audit was to verify compliance with the regulatory requirements stipulated by the national regulatory body. The audit mainly covered accuracy check of accelerating potential (kVp), linearity of tube current (mA station) and timer, congruence of radiation and optical field, and total filtration; in addition, we also reviewed medical X-ray diagnostic installations with reference to room layout of X-ray machines and conduct of radiological protection survey. A QA kit consisting of a kVp Test-O-Meter (ToM) (Model RAD/FLU-9001), dose Test-O-Meter (ToM) (Model 6001), ionization chamber-based radiation survey meter model Gun Monitor and other standard accessories were used for the required measurements. The important areas where there was noncompliance with the national safety code were: inaccuracy of kVp calibration (23%), lack of congruence of radiation and optical field (23%), nonlinearity of mA station (16%) and timer (9%), improper collimator/diaphragm (19.6%), faulty adjustor knob for alignment of field size (4%), nonavailability of warning light (red light) at the entrance of the X-ray room (29%), and use of mobile protective barriers without lead glass viewing window (14%). The present study on the radiological safety status of diagnostic X-ray installations may be a reasonably good representation of the situation in the country as a whole. The study contributes significantly to the improvement of radiological safety by the way of the steps already taken and by providing a vital feed back to the national regulatory body. (author)

  18. [The characteristics of medical technologies in emergency medical care hospital].

    Science.gov (United States)

    Murakhovskiĭ, A G; Babenko, A I; Bravve, Iu I; Tataurova, E A

    2013-01-01

    The article analyzes the implementation of major 12 diagnostic and 17 treatment technologies applied during medical care of patients with 12 key nosology forms of diseases in departments of the emergency medical care hospital No 2 of Omsk. It is established that key groups of technologies in the implementation of diagnostic process are the laboratory clinical diagnostic analyses and common diagnostic activities at reception into hospital and corresponding departments. The percentage of this kind of activities is about 78.3% of all diagnostic technologies. During the realization of treatment process the priority technologies are common curative and rehabilitation activities, intensive therapy activities and clinical diagnostic monitoring activities. All of them consist 80.1% of all curative technologies.

  19. Information needs assessment of medical equipment offices based on Critical Success Factors (CSF) and Business System Planning (BSP) methods.

    Science.gov (United States)

    Khorrami, F; Ahmadi, M; Alizadeh, A; Roozbeh, N; Mohseni, S

    2015-01-01

    Introduction: Given the ever-increasing importance and value of information, providing the management with a reliable information system, which can facilitate decision-making regarding planning, organization and control, is vitally important. This study aimed to analyze and evaluate the information needs of medical equipment offices. Methods: This descriptive applied cross-sectional study was carried out in 2010. The population of the study included the managers of statistic and medical records at the offices of vice-chancellor for treatment in 39 medical universities in Iran. Data were collected by using structured questioners. With regard to different kinds of designing information systems, sampling was done by two methods, BSP (based on processes of job description) and CSF method (based on critical success factors). The data were analyzed by SPSS-16. Results: Our study showed that 41% of information needs were found to be critical success factors of managers of office. The first priority of managers was "the number of bed and bed occupancy in hospitals". Of 29 identified information needs, 62% were initial information needs of managers (from the viewpoints of managers). Of all, 4% of the information needs were obtained through the form, 14% through both the form and database, 11% through the web site, and 71% had no sources (forms, databases, web site). Conclusion: Since 71% of the information needs of medical equipment offices managers had no information sources, the development of information system in these offices seems to be necessary. Despite the important role of users in designing the information systems (identifying 62% of information needs), other scientific methods is also needed to be utilized in designing the information systems.

  20. Information needs assessment of medical equipment offices based on Critical Success Factors (CSF) and Business System Planning (BSP) methods

    Science.gov (United States)

    Khorrami, F; Ahmadi, M; Alizadeh, A; Roozbeh, N; Mohseni, S

    2015-01-01

    Introduction: Given the ever-increasing importance and value of information, providing the management with a reliable information system, which can facilitate decision-making regarding planning, organization and control, is vitally important. This study aimed to analyze and evaluate the information needs of medical equipment offices. Methods: This descriptive applied cross-sectional study was carried out in 2010. The population of the study included the managers of statistic and medical records at the offices of vice-chancellor for treatment in 39 medical universities in Iran. Data were collected by using structured questioners. With regard to different kinds of designing information systems, sampling was done by two methods, BSP (based on processes of job description) and CSF method (based on critical success factors). The data were analyzed by SPSS-16. Results: Our study showed that 41% of information needs were found to be critical success factors of managers of office. The first priority of managers was “the number of bed and bed occupancy in hospitals”. Of 29 identified information needs, 62% were initial information needs of managers (from the viewpoints of managers). Of all, 4% of the information needs were obtained through the form, 14% through both the form and database, 11% through the web site, and 71% had no sources (forms, databases, web site). Conclusion: Since 71% of the information needs of medical equipment offices managers had no information sources, the development of information system in these offices seems to be necessary. Despite the important role of users in designing the information systems (identifying 62% of information needs), other scientific methods is also needed to be utilized in designing the information systems. PMID:28255389

  1. Quality Control Program for radiodiagnostic equipment on the Department of Antioquia, Colombia

    International Nuclear Information System (INIS)

    Beltran, Camilo; Viloria, Carolina; Puerta, Anselmo; Morales, Javier; Martinez, Piedad

    2008-01-01

    The Health Sectional Direction of Antioquia DSSA and the National University of Colombia campus Medellin have been formalizing inter-administrative agreements to realize Quality Control Studies on the institutions of medical radiodiagnostics of the department. In the first phase of the project on 2006, quality control studies were completed on 40 conventional and 31 mammography equipment, in the second phase by the end of 2006, 21 fluoroscopy, interventionism and C arms equipment were also studied; the third phase, finished by the end of 2007, counted with 50 conventional equipment. The tests proposed on the ARCAL XLIX IAEA protocol, tests on the installations, on the generator, on the image systems and the patient dosimetry were performed. From the evaluations on the installations, reports with relevant recommendations to be considerate and implemented to perform a better use of own resources on each institution were elaborated. On this paper, current results, impact on the participating institutions and the benefits from the applications that these kinds of practices bring to the institutions are presented. Finally, the necessity to advance towards clear politics in order to impulse the implementation of quality assurance programs in radiodiagnostic institutions, looking to improve the quality of diagnostic images with patient benefits, higher trust on technical conditions of equipment for a better and adequate diagnose, as well as to advance on processes seeking the optimization of radiological protection on the patient and the personnel occupationally exposed, is presented. (author)

  2. The diagnostic accuracy of three rapid diagnostic tests for typhoid fever at Chittagong Medical College Hospital, Chittagong, Bangladesh.

    Science.gov (United States)

    Maude, Rapeephan R; de Jong, Hanna K; Wijedoru, Lalith; Fukushima, Masako; Ghose, Aniruddha; Samad, Rasheda; Hossain, Mohammed Amir; Karim, Mohammed Rezaul; Faiz, Mohammed Abul; Parry, Christopher M

    2015-10-01

    To determine the diagnostic accuracy of three rapid diagnostic tests (RDTs) for typhoid fever in febrile hospitalised patients in Bangladesh. Febrile adults and children admitted to Chittagong Medical College Hospital, Bangladesh, were investigated with Bact/Alert(®) blood cultures and real-time PCR to detect Salmonella enterica Typhi and Paratyphi A and assays for Rickettsia, leptospirosis and dengue fever. Acute serum samples were examined with the LifeAssay (LA) Test-it™ Typhoid IgM lateral flow assay detecting IgM antibodies against S. Typhi O antigen, CTKBiotech Onsite Typhoid IgG/IgM Combo Rapid-test cassette lateral flow assay detecting IgG and IgM antibodies against S. Typhi O and H antigens and SD Bioline line assay for IgG and IgM antibodies against S. Typhi proteins. In 300 malaria smear-negative febrile patients [median (IQR) age of 13.5 (5-31) years], 34 (11.3%) had confirmed typhoid fever: 19 positive by blood culture for S. Typhi (three blood PCR positive) and 15 blood culture negative but PCR positive for S. Typhi in blood. The respective sensitivity and specificity of the three RDTs in patients using a composite reference standard of blood culture and/or PCR-confirmed typhoid fever were 59% and 61% for LifeAssay, 59% and 74% for the CTK IgM and/or IgG, and 24% and 96% for the SD Bioline RDT IgM and/or IgG. The LifeAssay RDT had a sensitivity of 63% and a specificity of 91% when modified with a positive cut-off of ≥2+ and analysed using a Bayesian latent class model. These typhoid RDTs demonstrated moderate diagnostic accuracies, and better tests are needed. © 2015 The Authors. Tropical Medicine & International Health Published by John Wiley & Sons Ltd.

  3. Quality assurance procedures in radiotherapy - IEC specifications for equipment

    Energy Technology Data Exchange (ETDEWEB)

    Rassow, J; Klieber, E

    1986-08-01

    The International Electrotechnical Commission (IEC) worked out international standards for requirements and tests of electrical, mechanical and radiation safety as well as for definition and tests of functional performance characteristics of radiotherapy equipments (medical electron accelerators, gamma beam teletherapy and afterloading equipments, simulators and accessories) and for clinical dosimeters and terminology for medical radiology. A survey is given on the actual state of standardization projects. The problems of such standards are shown for the standard for functional performance characteristics of medical electron accelerators as example.

  4. Quality assurance procedures in radiotherapy - IEC specifications for equipment

    International Nuclear Information System (INIS)

    Rassow, J.; Klieber, E.

    1986-01-01

    The International Electrotechnical Commission (IEC) worked out international standards for requirements and tests of electrical, mechanical and radiation safety as well as for definition and tests of functional performance characteristics of radiotherapy equipments (medical electron accelerators, gamma beam teletherapy and afterloading equipments, simulators and accessories) and for clinical dosimeters and terminology for medical radiology. A survey is given on the actual state of standardization projects. The problems of such standards are shown for the standard for functional performance characteristics of medical electron accelerators as example. (orig.) [de

  5. Rapid detection of chromosome rearrangement in medical diagnostic X-ray workers by using fluorescence in situ hybridization and study on dose estimation

    International Nuclear Information System (INIS)

    Wang Zhiquan; Sun Yuanming; Li Jin

    1998-01-01

    Objective: Biological doses were estimated for medical diagnostic X-ray workers. Methods: Chromosome rearrangements in X-ray workers were analysed by fluorescence in situ hybridization (FISH) with composite whole chromosome paintings number 4 and number 7. Results: The frequency of translocation in medical diagnostic X-ray workers was much higher than that in control group (P<0.01). The biological doses to individual X-ray workers were calculated by their translocation frequency. The translocation frequencies of both FISH and G-banding were in good agreement. Conclusion: The biological doses to X-ray workers are estimated by FISH first when their dosimetry records are not documented

  6. [The set of wearable medical equipment for medical and nursing teams].

    Science.gov (United States)

    Efimenko, N a; Valevskii, V V; Lyutov, V V; Makhnovskii, A I; Sorokin, S I; Blinda, I V

    2015-06-01

    The kit is designed in accordance with the list of the first medical aid procedures and syndromic standards of emergency medical care providing. The kit contains modern local hemostatic agents, vent tubes, cricothyrotomy, needles to eliminate pneumothorax, portable oxygen machine, sets for intravenous and intraosseous infusion therapy, collapsible plastic tires, anti-shock pelvic girdle, and other medical products and pharmaceuticals. As containers used backpack and trolley bag on wheels camouflage colours. For the convenience and safety of the personnel of the vest is designed discharge to be converted in the body armour.

  7. SU-F-E-01: Pitfalls: Reliability and Performance of Diagnostic X-Sources

    Energy Technology Data Exchange (ETDEWEB)

    Behling, R [Philips Medical Systems DMC GmbHHamburg (United States)

    2016-06-15

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. The author is employee of Royal Philips.

  8. SU-F-E-01: Pitfalls: Reliability and Performance of Diagnostic X-Sources

    International Nuclear Information System (INIS)

    Behling, R

    2016-01-01

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. The author is employee of Royal Philips

  9. 46 CFR 197.454 - First aid and treatment equipment.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false First aid and treatment equipment. 197.454 Section 197.454 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE OCCUPATIONAL SAFETY AND... Equipment § 197.454 First aid and treatment equipment. The diving supervisor shall ensure that medical kits...

  10. Calibration of dosimeters used in diagnostic radiology in terms of air kerma rate

    International Nuclear Information System (INIS)

    Soluman, M. H.

    2012-10-01

    This study was performed to determine IEC reference radiation beam quality for calibrating dosimeters used in diagnostic radiology. Additional filtration required to establish certain IEC quality was estimated from beam transmission measurements using Al absorbers. The experiment was carried out using medical x-ray equipment at Neelain Medical Center, Khartoum. The required added filtration thickness required to establish RQA quality was estimated according to the the method described in the IEC standard. The required filtration was estimated for each of radiation quality (40, 60, 80, 100, 120,) kV. Result showed the maximum deviation of 2.3%, for the half value-layers, which complied with the standard requirement of 3%, the additional filtration required for the RQA qualities was found to as follows: 1.2 mmAL (RQA2, 40 kV), 11.0 mmAL (RQA3, 60 kV), 20.7 mmAL ( RQA4, 80 kV), 29.5 mmAL (RQA5, 100 kV) and 33.0 mmAL (AQA6, 120 kV), those qualities recommended to be applied to calibration of the diagnostic radiology measurements instruments in Sudan.(Author)

  11. An overview of medical image data base

    International Nuclear Information System (INIS)

    Nishihara, Eitaro

    1992-01-01

    Recently, the systematization using computers in medical institutions has advanced, and the introduction of hospital information system has been almost completed in the large hospitals with more than 500 beds. But the objects of the management of the hospital information system are text information, and do not include the management of images of enormous quantity. By the progress of image diagnostic equipment, the digitization of medical images has advanced, but the management of images in hospitals does not utilize the merits of digital images. For the purpose of solving these problems, the picture archiving and communication system (PACS) was proposed about ten years ago, which makes medical images into a data base, and enables the on-line access to images from various places in hospitals. The studies have been continued to realize it. The features of medical image data, the present status of utilizing medical image data, the outline of the PACS, the image data base for the PACS, the problems in the realization of the data base and the technical trend, and the state of actual construction of the PACS are reported. (K.I.)

  12. Medical isotope uses in Thailand

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1960-01-15

    In February 1959, the International Atomic Energy Agency sent an expert to Thailand to assist in the development of the medical application of radioisotopes, particularly in diagnosis and clinical research. The IAEA expert was to gave a series of lectures to groups of medical workers in order to provide them with an introductory account of the various applications of radioisotopes in medicine. Work with radioisotopes was already under way at the Radiology Department of Siriraj Hospital, where 15 to 20 patients were referred to the Department each week for tests with radioactive iodine used as a tracer. A number of cases had also been treated with therapeutic doses of radioiodine. The laboratory is well provided with nucleonic equipment and certain additional items of essential equipment were obtained under the IAEA expert's guidance. Certain delays were, however, experienced in obtaining supplies of radioisotopes from abroad because of customs and other import regulations, and the expert regarded the establishment of a simplified procedure. The existing facilities, techniques and organization of work at the laboratory were improved and a new diagnostic procedures was established on a routine basis. For example, the dispensing of routine tracer doses of radioiodine was simplified and reorganized. Again, a specialized system for measuring the output of the heart with the help of radioisotopes was established for the investigation of patients with cardiac disorders

  13. Needs, conditions of intervention and staff in medical physics for medical imagery

    International Nuclear Information System (INIS)

    Salvat, Cecile; Dieudonne, Arnaud; Guilhem, Marie-Therese; Le Du, Dominique; Pierrat, Noelle; Isambert, Aurelie; Valero, Marc; Blanchard, Vincent

    2013-04-01

    This guide proposes information on the types and quantification of medical physics tasks to be performed when performing medical imagery using ionizing radiations. It gives recommendations about the commitment of medical physicists (with or without support staff) and the required staff in nuclear medicine and, more generally in imagery (interventional radiology, scanography, conventional radiology). It first gives an overview of the situation in France in 2012 in terms of observations made by the ASN during inspections, and of results of a survey conducted among medical physicists involved in medical imagery. It indicates the current regulatory requirements, and international and national recommendations, and describes the commitment in imagery of medical physicists in three countries (Spain, Belgium and Germany). It analyses and describes the fields of intervention of medical physicists in imagery and identifies associated tasks in France (in equipment purchasing, equipment installation, equipment routine usage, patient care, nuclear medicine or internal vectorized radiotherapy, or staff training). Recommendations of a work-group about sizing criteria are proposed

  14. Identifying the cause of intermittent problems in diagnostic X-ray machines

    International Nuclear Information System (INIS)

    Addison, S.J.; O'Brien, M.J.; Robb, D.B.

    1987-01-01

    Quality assurance testing and performance evaluation of radiologic x-ray equipment is an important part of producing acceptable diagnostic quality images with minimum patient exposure. Regulatory and advisory agencies provide guidance for performing these tests, but it is often only obvious problems which are detected without extensive investigation. It is desirable for the Health Physicist to be able to determine the cause of an intermittent ''bad film'' with a minimum of test equipment. This paper relates some significant performance anomalies which have been identified in diagnostic x-ray equipment from installations in the Seattle area. Many of these problems eluded manufacturer's service personnel. Also included is a description of simple steps which can be included in test procedures to detect these equipment irregularities

  15. Relationship between type of medical institutions according to the equipment list and inspection fee computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Cheol; Lim, Cheong Hwan; Joo, Yeong Cheol [Dept. of Dept. of Health Care, Hanseo University, Seosan (Korea, Republic of)

    2014-12-15

    This study demonstrates holding condition of CT by medical institution classification and by season, and examination fee in Korea currently to quantitatively understand frequency of examination region by change of CT equipment, domestic growing trend and change of distribution and using rate. Recent 10 years of CT holding condition by medical institution classification (Tertiary hospital, General hospital, Hospital, Clinic, Dental hospital, Dental clinic, Hospitalized health center) and by year (2003-2012), and CT examination fee of distribution of medical institution by year is surveyed. The holding ratio of Tertiary hospital level and General hospital level is 32.7% in 2003 and 33.0% in 2012. Whereas, Hospital and Clinic level is 74.2% in 2003 and 66.8% in 2012, which takes approximately 70%. Based on data in 2012, it is 82.2% of total examination fee in Tertiary hospital and General hospital, while 17.5% in hospital and clinic. CT holding rate of Hospital level is increasing, while Clinic level is decreasing. Approximately 80% of CT examination fee is claimed by Tertiary hospital and General hospital. Therefore, there is a significant correlation between CT holding condition of medical institution classification and examination fee. Particularly, correlation between CT holding number of Tertiary hospital and examination fee is significant (p< .001). The more CT holding number, the higher the amount claimed examination fee.

  16. Relationship between type of medical institutions according to the equipment list and inspection fee computed tomography

    International Nuclear Information System (INIS)

    Kim, Min Cheol; Lim, Cheong Hwan; Joo, Yeong Cheol

    2014-01-01

    This study demonstrates holding condition of CT by medical institution classification and by season, and examination fee in Korea currently to quantitatively understand frequency of examination region by change of CT equipment, domestic growing trend and change of distribution and using rate. Recent 10 years of CT holding condition by medical institution classification (Tertiary hospital, General hospital, Hospital, Clinic, Dental hospital, Dental clinic, Hospitalized health center) and by year (2003-2012), and CT examination fee of distribution of medical institution by year is surveyed. The holding ratio of Tertiary hospital level and General hospital level is 32.7% in 2003 and 33.0% in 2012. Whereas, Hospital and Clinic level is 74.2% in 2003 and 66.8% in 2012, which takes approximately 70%. Based on data in 2012, it is 82.2% of total examination fee in Tertiary hospital and General hospital, while 17.5% in hospital and clinic. CT holding rate of Hospital level is increasing, while Clinic level is decreasing. Approximately 80% of CT examination fee is claimed by Tertiary hospital and General hospital. Therefore, there is a significant correlation between CT holding condition of medical institution classification and examination fee. Particularly, correlation between CT holding number of Tertiary hospital and examination fee is significant (p< .001). The more CT holding number, the higher the amount claimed examination fee

  17. Radiological safety status and quality assurance audit of medical X-ray diagnostic installations in India

    Directory of Open Access Journals (Sweden)

    Sonawane A

    2010-01-01

    Full Text Available We conducted a radiological safety and quality assurance (QA audit of 118 medical X-ray diagnostic machines installed in 45 major hospitals in India. The main objective of the audit was to verify compliance with the regulatory requirements stipulated by the national regulatory body. The audit mainly covered accuracy check of accelerating potential (kVp, linearity of tube current (mA station and timer, congruence of radiation and optical field, and total filtration; in addition, we also reviewed medical X-ray diagnostic installations with reference to room layout of X-ray machines and conduct of radiological protection survey. A QA kit consisting of a kVp Test-O-Meter (ToM (Model RAD/FLU-9001, dose Test-O-Meter (ToM (Model 6001, ionization chamber-based radiation survey meter model Gun Monitor and other standard accessories were used for the required measurements. The important areas where there was noncompliance with the national safety code were: inaccuracy of kVp calibration (23%, lack of congruence of radiation and optical field (23%, nonlinearity of mA station (16% and timer (9%, improper collimator/diaphragm (19.6%, faulty adjustor knob for alignment of field size (4%, nonavailability of warning light (red light at the entrance of the X-ray room (29%, and use of mobile protective barriers without lead glass viewing window (14%. The present study on the radiological safety status of diagnostic X-ray installations may be a reasonably good representation of the situation in the country as a whole. The study contributes significantly to the improvement of radiological safety by the way of the steps already taken and by providing a vital feed back to the national regulatory body.

  18. Delivering health information about self-medication to older adults: use of touchscreen-equipped notebook computers.

    Science.gov (United States)

    Neafsey, P J; Strickler, Z; Shellman, J; Padula, A T

    2001-11-01

    Preventing Drug Interactions in Active Older Adults is an educational intervention to prevent prescription and over-the-counter (OTC) drug and alcohol interactions in active, community-living older adults. The objectives of the program are to increase older adults' knowledge of potential interactions of prescription medications with OTC drugs and alcohol and to increase their confidence (self-efficacy) about how to avoid such interactions. An interactive multimedia computer software program (Personal Education Program or PEP) was designed for the learning styles and psychomotor skills of older adults. Focus groups of older adults evaluated PEP components in a formative manner during development. The program content dealing with antacids, calcium supplements, and acid reducers was pilot tested with 60 older adults recruited from local senior centers. Participants used the PEP on notebook computers equipped with infrared-sensitive touchscreens. Users of PEP had greater knowledge and self-efficacy scores than controls. Participants indicated a high degree of satisfaction with the PEP and reported their intent to make specific changes in self-medication behaviors.

  19. Quality control of diagnostic X-ray installations for conventional radiography in the period of their clinical use-methods and results of their implementation

    International Nuclear Information System (INIS)

    Vassileva, J.

    2000-01-01

    A guide on the qualify assurance in x-ray diagnostics, developed for Bulgarian medical physicists and other specialists is presented. All measurement described have been testing for three years in the Department of Radiology in the Regional Hospital in Shoumen. The guide covers only tests on the x-ray equipment. A list of test measurements as well as recommendations for the minimum frequency of a routine performance testing are given

  20. The future of medical diagnostics: review paper

    LENUS (Irish Health Repository)

    Jerjes, Waseem K

    2011-08-23

    Abstract While histopathology of excised tissue remains the gold standard for diagnosis, several new, non-invasive diagnostic techniques are being developed. They rely on physical and biochemical changes that precede and mirror malignant change within tissue. The basic principle involves simple optical techniques of tissue interrogation. Their accuracy, expressed as sensitivity and specificity, are reported in a number of studies suggests that they have a potential for cost effective, real-time, in situ diagnosis. We review the Third Scientific Meeting of the Head and Neck Optical Diagnostics Society held in Congress Innsbruck, Innsbruck, Austria on the 11th May 2011. For the first time the HNODS Annual Scientific Meeting was held in association with the International Photodynamic Association (IPA) and the European Platform for Photodynamic Medicine (EPPM). The aim was to enhance the interdisciplinary aspects of optical diagnostics and other photodynamic applications. The meeting included 2 sections: oral communication sessions running in parallel to the IPA programme and poster presentation sessions combined with the IPA and EPPM posters sessions.

  1. Establish radiation protection programme for diagnostic radiology

    International Nuclear Information System (INIS)

    Mboya, G.

    2014-01-01

    Mammography is an effective method used for breast diagnostics and screening. The aim of this project is to review the literature on how to establish radiation protection programme for mammography in order to protect the patients, the occupationally exposed workers and the members of the public from harmful effects of ionizing radiation. It reviews some of the trends in mammography doses and dosimetric principles such as average glandular dose in the glandular tissue which is used for description of radiation risk, also the factors affecting patient doses are discussed. However, the average glandular dose should not be used directly to estimate the radiation risk from mammography. Risk is calculated under certain assumptions from determined entrance surface air kerma. Given the increase in population dose, emphasis is placed on the justification and optimization of the mammographic procedures. Protection is optimized by the radiation dose being appropriate with the purpose of the mammographic examination. The need to establish diagnostic reference levels as an optimization is also discussed. In order to obtain high quality mammograms at low dose to the breast, it is necessary to use the correct equipment and perform periodic quality control tests on mammography equipment. It is noted that in order to achieve the goal of this project, the application of radiation protection should begin at the time of requesting for mammography examination, positioning of the patient, irradiation, image processing and interpretation of mammogram. It is recommended that close cooperation between radiology technologists, radiologist, medical physicists, regulatory authority and other support workers be required and established to obtain a consistent and effective level of radiation protection in a mammography facility. (author)

  2. The Application of Whole Cell-Based Biosensors for Use in Environmental Analysis and in Medical Diagnostics

    Science.gov (United States)

    Gui, Qingyuan; Lawson, Tom; Shan, Suyan; Yan, Lu; Liu, Yong

    2017-01-01

    Various whole cell-based biosensors have been reported in the literature for the last 20 years and these reports have shown great potential for their use in the areas of pollution detection in environmental and in biomedical diagnostics. Unlike other reviews of this growing field, this mini-review argues that: (1) the selection of reporter genes and their regulatory proteins are directly linked to the performance of celllular biosensors; (2) broad enhancements in microelectronics and information technologies have also led to improvements in the performance of these sensors; (3) their future potential is most apparent in their use in the areas of medical diagnostics and in environmental monitoring; and (4) currently the most promising work is focused on the better integration of cellular sensors with nano and micro scaled integrated chips. With better integration it may become practical to see these cells used as (5) real-time portable devices for diagnostics at the bedside and for remote environmental toxin detection and this in situ application will make the technology commonplace and thus as unremarkable as other ubiquitous technologies. PMID:28703749

  3. Inquiry about the uses of special equipment (CT equipment, angiography systems, mammography devices, screens)

    International Nuclear Information System (INIS)

    Schwager, P.; Stieve, F.E.

    1986-01-01

    There are at least 1100 special devices in medical establishment in Bavaria which require special inspection and surveillance with regard to quality of equipment and radiation protection. In addition, there are at least 53 tomographs available for operation, and at least 120 installed X-ray screens. These devices need special approval testing and quality control services as they contribute a very significant amount of the medically indicated radiation exposure of the population. Appropriate measures are explained that can be applied in order to reduce the medical radiation exposure to an optimum. (orig.) [de

  4. The engineering of JET diagnostics

    International Nuclear Information System (INIS)

    Walker, C.I.; Dillon, S.F.; Hammond, N.P.; Hancock, C.J.; Lam, N.; McCarron, E.J.; Prior, P.C.S.; Reid, J.; Sanders, S.; Tellier, X.; Tiscornia, A.J.; Whitfield, G.A.H.; Wilson, C.H.; Wilson, D.J.

    1995-01-01

    There are some 62 identifiably different diagnostic systems on JET. 22 were installed new at the last, Pumped Divertor, shutdown and a further 22 which were modified, upgraded or repositioned. This paper describes some of the engineering aspects peculiar to the renewed diagnostic systems, reviews their construction and installation and gives an overview of the design of presently installed diagnostic equipment at the Torus. Examples are considered that illustrate the breakdown into a categorisation based on their installation method. This is useful for discussion of many of the associated engineering problems of method and quality control of manufacture, vulnerability, access for installation and maintenance and ultimately system safety and reliability. The function and measured plasma parameter of specific diagnostics is covered in other papers and is not attempted here, neither is a full catalogue of Diagnostics on JET. (orig.)

  5. Disinfection protocols for necropsy equipment in rabies laboratories: Safety of personnel and diagnostic outcome.

    Science.gov (United States)

    Aiello, Roberta; Zecchin, Barbara; Tiozzo Caenazzo, Silvia; Cattoli, Giovanni; De Benedictis, Paola

    2016-08-01

    In the last decades, molecular techniques have gradually been adopted for the rapid confirmation of results obtained through gold standard methods. However, international organisations discourage their use in routine laboratory investigations for rabies post-mortem diagnosis, as they may lead to false positive results due to cross-contamination. Cleaning and disinfection are essential to prevent cross-contamination of samples in the laboratory environment. The present study evaluated the efficacy of selected disinfectants on rabies-contaminated necropsy equipment under organic challenge using a carrier-based test. The occurrence of detectable Rabies virus (RABV) antigen, viable virus and RNA was assessed through the gold standard Fluorescent Antibody Test, the Rabies Tissue Culture Infection Test and molecular techniques, respectively. None of the tested disinfectants proved to be effective under label conditions. Off label disinfection protocols were found effective for oxidizing agents and phenolic, only. Biguanide and quaternary ammonium compound were both ineffective under all tested conditions. Overall, discordant results were obtained when different diagnostic tests were compared, which means that in the presence of organic contamination common disinfectants may not be effective enough on viable RABV or RNA. Our results indicate that an effective disinfection protocol should be carefully validated to guarantee staff safety and reliability of results. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  6. 21 CFR 1000.50 - Recommendation for the use of specific area gonad shielding on patients during medical diagnostic...

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Recommendation for the use of specific area gonad shielding on patients during medical diagnostic x-ray procedures. 1000.50 Section 1000.50 Food and Drugs... GENERAL Radiation Protection Recommendations § 1000.50 Recommendation for the use of specific area gonad...

  7. Evaluation of video capture equipment for secondary image acquisition in the PACS.

    Science.gov (United States)

    Sukenobu, Yoshiharu; Sasagaki, Michihiro; Hirabuki, Norio; Naito, Hiroaki; Narumi, Yoshifumi; Inamura, Kiyonari

    2002-01-01

    There are many cases in which picture archiving and communication systems (PACS) are built with old-type existing modalities with no DICOM output. One of the methods for interfacing them to the PACS is to implement video capture (/ frame grabber) equipment. This equipment takes analog video signal output from medical imaging modalities, and amplitude of the video signal is A/D converted and supplied to the PACS. In this report, we measured and evaluated the accuracy at which this video capture equipment could capture the image. From the physical evaluation, we found the pixel values of an original image and its captured image were almost equal in gray level from 20%-90%. The change in the pixel values of a captured image was +/-3 on average. The change of gray level concentration was acceptable and had an average standard deviation of around 0.63. As for resolution, the degradation was observed at the highest physical level. In a subjective evaluation, the evaluation value of the CT image had a grade of 2.81 on the average (the same quality for a reference image was set to a grade of 3.0). Abnormalities in heads, chests, and abdomens were judged not to influence diagnostic accuracy. Some small differences were seen when comparing captured and reference images, but they are recognized as having no influence on the diagnoses.

  8. Method of estimating patient skin dose from dose displayed on medical X-ray equipment with flat panel detector

    International Nuclear Information System (INIS)

    Fukuda, Atsushi; Koshida, Kichiro; Togashi, Atsuhiko; Matsubara, Kousuke

    2004-01-01

    The International Electrotechnical Commission (IEC) has stipulated that medical X-ray equipment for interventional procedures must display radiation doses such as air kerma in free air at the interventional reference point and dose area product to establish radiation safety for patients (IEC 60601-2-43). However, it is necessary to estimate entrance skin dose for the patient from air kerma for an accurate risk assessment of radiation skin injury. To estimate entrance skin dose from displayed air kerma in free air at the interventional reference point, it is necessary to consider effective energy, the ratio of the mass-energy absorption coefficient for skin and air, and the backscatter factor. In addition, since automatic exposure control is installed in medical X-ray equipment with flat panel detectors, it is necessary to know the characteristics of control to estimate exposure dose. In order to calculate entrance skin dose under various conditions, we investigated clinical parameters such as tube voltage, tube current, pulse width, additional filter, and focal spot size, as functions of patient body size. We also measured the effective energy of X-ray exposure for the patient as a function of clinical parameter settings. We found that the conversion factor from air kerma in free air to entrance skin dose is about 1.4 for protection. (author)

  9. SPECIFICITY OF MANIFACTURING PROCESS VALIDATION FOR DIAGNOSTIC SEROLOGICAL DEVICES

    Directory of Open Access Journals (Sweden)

    O. Yu. Galkin

    2018-02-01

    Full Text Available The aim of this research was to analyze recent scientific literature, as well as national and international legislature on manifacturing process validation of biopharmaceutical production, in particular devices for serological diagnostics. Technology validation in the field of medical devices for serological diagnostics is most influenced by the Technical Regulation for Medical Devices for in vitro Diagnostics State Standards of Ukraine – SSU EN ISO 13485:2015 “Medical devices. Quality management system. Requirements for regulation”, SSU EN ISO 14971:2015 “Medical devices. Instructions for risk management”, Instruction ST-N of the Ministry of Healthcare of Ukraine 42-4.0:2014 “Medications. Suitable industrial practice”, State Pharmacopoeia of Ukraine and Instruction ICH Q9 on risk management. Current recommendations for validations of drugs manufacturing process, including biotechnological manufacturing, can not be directly applied to medical devices for in vitro diagnostics. It was shown that the specifics of application and raw materials require individual validation parameters and process validations for serological diagnostics devices. Critical parameters to consider in validation plans were provided for every typical stage of production of in vitro diagnostics devices on the example of immunoassay kits, such as obtaining protein antigens, including recombinant ones, preparations of mono- and polyclonal antibodies, immunoenzyme conjugates and immunosorbents, chemical reagents etc. The bottlenecks of technologies for in vitro diagnostics devices were analyzed from the bioethical and biosafety points of view.

  10. Molecular diagnostics: the changing culture of medical microbiology.

    Science.gov (United States)

    Bullman, Susan; Lucey, Brigid; Sleator, Roy D

    2012-01-01

    Diagnostic molecular biology is arguably the fastest growing area in current laboratory-based medicine. Growth of the so called 'omics' technologies has, over the last decade, led to a gradual migration away from the 'one test, one pathogen' paradigm, toward multiplex approaches to infectious disease diagnosis, which have led to significant improvements in clinical diagnostics and ultimately improved patient care.

  11. Comparison of 3MP medical-grade to 1MP office grade LCD monitors in mammographic diagnostic and perceptual performance

    International Nuclear Information System (INIS)

    Ong, Aaron; Tan, Shu.; Gledhill, Samuel; Hennessy, Oliver; Lui, Belinda; Lee, Alan; Lemish, Wayne; Styles, Colin; Pun, Emma; Padmanabhan, Meenakshi; Pitman, Alexander G.; Tauro, Paul; Waugh, Paul

    2011-01-01

    Full text: Picture archiving and communication systems images designed to be viewed on high-resolution medical-grade monitors are routinely viewed on office-grade monitors on the wards or at home. This study aimed to determine whether a statistically significant difference in diagnostic (cancer detection) and perceptual (microcalcification detection) performance exists between 3MP grade and 1MP office-grade monitors. 3MP Dome medical-grade liquid crystal display (LCD) monitors (Planar, Beaverton, OR, USA) were compared to 1MP Dell office-grade LCD monitors (Dell Inc, Round Rock, TX, USA). Eight radiologists (reader experi ence 8-30 years) read the same set of 100 mammograms (23/100 with proven cancers and 52/100 with microcalcifications) presented in random order on three occasions separated by two time intervals of 12 weeks. Reads 1 and 3 utilised 3MP monitors and formed the baseline read. Read 2 utilised 1MP monitors and constituted the experimental read. Reading conditions were standardised. Readers were aware of which monitors they were using. Mul tivariate logistic regression analysis (to account for reader variability and monitor impact) was performed to assess for statistical significance. At a = 5%, confidence intervals analysis comparing the measured parameters between 1MP to 3MP monitors demonstrated no statistically significant difference in diagnostic and perceptual performance for the reader group. In cancer detection (the diagnostic task), reader accuracy remained high irrespective of monitor type. Regression analysis comparing performance with 1MP against 3MP monitors found P values of 0.693 and 0.324 for diagnostic and perceptual performance, respectively. There were no statistically and clinically significant differences between 3MP and 1MP monitors in mammographic diagnostic and perceptual performance. Comparable performance may be due to compensatory behav iour by readers.

  12. 21 CFR 866.4500 - Immunoelectrophoresis equipment.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents... clinical use with its electrical power supply is a device used for separating protein molecules...

  13. 21 CFR 886.1380 - Diagnostic condensing lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Diagnostic condensing lens. 886.1380 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1380 Diagnostic condensing lens. (a) Identification. A diagnostic condensing lens is a device used in binocular indirect ophthalmoscopy (a procedure...

  14. Exposure of the French paediatric population to ionising radiation from diagnostic medical procedures in 2010

    International Nuclear Information System (INIS)

    Etard, Cecile; Aubert, Bernard; Mezzarobba, Myriam; Bernier, Marie-Odile

    2014-01-01

    Medical examination is the main source of artificial radiation exposure. Because children present an increased sensitivity to ionising radiation, radiology practices at a national level in paediatrics should be monitored. This study describes the ionising radiation exposure from diagnostic medical examinations of the French paediatric population in 2010. Data on frequency of examinations were provided by the French National Health Insurance through a representative sample including 107,627 children ages 0-15 years. Effective doses for each type of procedure were obtained from the published French literature. Median and mean effective doses were calculated for the studied population. About a third of the children were exposed to at least one examination using ionising radiation in 2010. Conventional radiology, dental exams, CT scans and nuclear medicine and interventional radiology represent respectively 55.3%, 42.3%, 2.1% and 0.3% of the procedures. Children 10-15 years old and babies from birth to 1 year are the most exposed populations, with respectively 1,098 and 734 examinations per 1,000 children per year. Before 1 year of age, chest and pelvis radiographs are the most common imaging tests, 54% and 32%, respectively. Only 1% of the studied population is exposed to CT scan, with 62% of these children exposed to a head-and-neck procedure. The annual median and mean effective doses were respectively 0.03 mSv and 0.7 mSv for the exposed children. This study gives updated reference data on French paediatric exposure to medical ionising radiation that can be used for public health or epidemiological purposes. Paediatric diagnostic use appears much lower than that of the whole French population as estimated in a previous study. (orig.)

  15. Exposure of the French paediatric population to ionising radiation from diagnostic medical procedures in 2010

    Energy Technology Data Exchange (ETDEWEB)

    Etard, Cecile; Aubert, Bernard [Institut de Radioprotection et de Surete Nucleaire, Medical Expertise Unit, Fontenay-aux-Roses (France); Mezzarobba, Myriam [Institut de Radioprotection et de Surete Nucleaire, Laboratory of Epidemiology, Fontenay-aux-Roses (France); Bernier, Marie-Odile [Institut de Radioprotection et de Surete Nucleaire, Laboratory of Epidemiology, Fontenay-aux-Roses (France); Institut de Radioprotection et de Surete Nucleaire, IRSN/PRP-HOM/SRBE/LEPID, Laboratoire d' Epidemiologie, Fontenay-aux-Roses (France)

    2014-12-15

    Medical examination is the main source of artificial radiation exposure. Because children present an increased sensitivity to ionising radiation, radiology practices at a national level in paediatrics should be monitored. This study describes the ionising radiation exposure from diagnostic medical examinations of the French paediatric population in 2010. Data on frequency of examinations were provided by the French National Health Insurance through a representative sample including 107,627 children ages 0-15 years. Effective doses for each type of procedure were obtained from the published French literature. Median and mean effective doses were calculated for the studied population. About a third of the children were exposed to at least one examination using ionising radiation in 2010. Conventional radiology, dental exams, CT scans and nuclear medicine and interventional radiology represent respectively 55.3%, 42.3%, 2.1% and 0.3% of the procedures. Children 10-15 years old and babies from birth to 1 year are the most exposed populations, with respectively 1,098 and 734 examinations per 1,000 children per year. Before 1 year of age, chest and pelvis radiographs are the most common imaging tests, 54% and 32%, respectively. Only 1% of the studied population is exposed to CT scan, with 62% of these children exposed to a head-and-neck procedure. The annual median and mean effective doses were respectively 0.03 mSv and 0.7 mSv for the exposed children. This study gives updated reference data on French paediatric exposure to medical ionising radiation that can be used for public health or epidemiological purposes. Paediatric diagnostic use appears much lower than that of the whole French population as estimated in a previous study. (orig.)

  16. Fuel-motion diagnostics and cineradiography

    International Nuclear Information System (INIS)

    DeVolpi, A.

    1982-09-01

    Nuclear and non-nuclear applications of cineradiography are reviewed, with emphasis on diagnostic instrumentation for in-pile transient-reactor safety testing of nuclear fuel motion. The primary instrument for this purpose has been the fast-neutron hodoscope, which has achieved quantitative monitoring of time, location, mass, and velocity of fuel movement under the difficult conditions associated with transient-reactor experiments. Alternative diagnostic devices that have been developed have not matched the capabilities of the hodoscope. Other applications for the fuel-motion diagnostic apparatus are also evolving, including time-integrated radiography and direct time- and space-resolved fuel-pin power monitoring. Although only two reactors are now actively equipped with high-resolution fuel-motion diagnostic systems, studies and tests have been carried out in and for many other reactors

  17. Assessment of medical occupational radiation doses in Costa Rica

    International Nuclear Information System (INIS)

    Mora, P.; Acuna, M.

    2011-01-01

    Participation of the Univ. of Costa Rica (UCR) in activities in an IAEA Regional Project RLA/9/066 through training, equipment and expert missions, has enabled to setting up of a national personal monitoring laboratory. Since 2007, the UCR has been in charge of monitoring around 1800 medical radiation workers of the Social Security System. Individual external doses are measured with thermoluminescent dosemeter using a Harshaw 6600 Plus reader. The service has accreditation with ISO/IEC 17025:2005. Distribution of monitored medical personnel is as follows: 83 % in diagnostic radiology, 6 % in nuclear medicine and 6 % in radiotherapy. Preliminary values for the 75 percentile of annual H p (10) in mSv are: radiology 0.37; interventional radiology 0.41; radiotherapy 0.53 and nuclear medicine 1.55. The service provided by the UCR in a steady and reliable way can help to implement actions to limit the doses received by the medical workers and optimise their radiation protection programs. (authors)

  18. Assessment of medical occupational radiation doses in Costa Rica.

    Science.gov (United States)

    Mora, P; Acuña, M

    2011-09-01

    Participation of the University of Costa Rica (UCR) in activities in an IAEA Regional Project RLA/9/066 through training, equipment and expert missions, has enabled to setting up of a national personal monitoring laboratory. Since 2007, the UCR has been in charge of monitoring around 1800 medical radiation workers of the Social Security System. Individual external doses are measured with thermoluminescent dosemeter using a Harshaw 6600 Plus reader. The service has accreditation with ISO/IEC 17025:2005. Distribution of monitored medical personnel is as follows: 83 % in diagnostic radiology, 6 % in nuclear medicine and 6 % in radiotherapy. Preliminary values for the 75 percentile of annual H(p)(10) in mSv are: radiology 0.37; interventional radiology 0.41; radiotherapy 0.53 and nuclear medicine 1.55. The service provided by the UCR in a steady and reliable way can help to implement actions to limit the doses received by the medical workers and optimise their radiation protection programs.

  19. Problems of steam turbine diagnostics and the 'Simens' diagnosis system

    International Nuclear Information System (INIS)

    Tserner, V.; Andrea, K.

    1993-01-01

    Diagnostics system, allowing one to detect changes in the state on single turbine elements at an early stage is described. Besides this system allows one to utilize the turbine plant optimally and efficiency from the viewpoint of the equipment durability. Specially oriented monitoring of the turbine plant and equipment element state saves resources necessary to keep up the working order of the equipment

  20. Potentiality Studies of Stainless Steel 304 Material for Production of Medical Equipment using Micro Electrical Discharge Machining (micro-EDM) Analysis and Modeling

    DEFF Research Database (Denmark)

    Puthumana, Govindan

    2016-01-01

    Stainless steel 304 (SS304) is a material widely used for production of medical equipment mainly because of its anti-corrosive properties. It has excellent mechanical properties, strength and reliability because of which it is one of the best materials for fabrication of medical devices. This paper...... and process parameters were developed. Grey relational analysis was used to optimize the micro-EDM quality characteristics, and the highest grey relational grade (GRG) of 0.8021 was obtained at a voltage of 100 V and a capacitance of 0.4 μF....

  1. [Medical equipment companies and their ties with technology development centers in Mexico].

    Science.gov (United States)

    Hernández, B; Arredondo, A; Cruz, C; Sánchez, E; Damián, T

    1993-10-01

    The purpose of this study was to determine the characteristics of the companies that produce, distribute, and service medical equipment in Mexico and the factors related to whether or not they had established ties with research and technology development centers. The data analyzed came from a survey of such companies carried out in Mexico City and environs in 1989. The information was updated in 1991. Multivariate analyses were carried out in order to identify the characteristics of companies that had established ties or wished to do so and the areas of interest of those companies. Of 208 companies surveyed, only 23% had ties with research centers. The companies that had such ties or were interested in establishing them tended to invest in research and to have made plans for expansion. The establishment of ties appeared to be a two-way process, with positive consequences for the companies involved, the research centers, and the health sector. It was concluded that it would be advantageous to design programs to promote ties with companies having the characteristics mentioned.

  2. Medical beam monitor—Pre-clinical evaluation and future applications

    Science.gov (United States)

    Frais-Kölbl, Helmut; Griesmayer, Erich; Schreiner, Thomas; Georg, Dietmar; Pernegger, Heinz

    2007-10-01

    Future medical ion beam applications for cancer therapy which are based on scanning technology will require advanced beam diagnostics equipment. For a precise analysis of beam parameters we want to resolve time structures in the range of microseconds to nanoseconds. A prototype of an advanced beam monitor was developed by the University of Applied Sciences Wiener Neustadt and its research subsidiary Fotec in co-operation with CERN RD42, Ohio State University and the Jožef Stefan Institute in Ljubljana. The detector is based on polycrystalline Chemical Vapor Deposition (pCVD) diamond substrates and is equipped with readout electronics up to 2 GHz analog bandwidth. In this paper we present the design of the pCVD-detector system and results of tests performed in various particle accelerator based facilities. Measurements performed in clinical high energy photon beams agreed within 1.2% with results obtained by standard ionization chambers.

  3. Medical beam monitor—Pre-clinical evaluation and future applications

    CERN Document Server

    Frais-Kölbl, H; Schreiner, T; Georg, D; Pernegger, H

    2007-01-01

    Future medical ion beam applications for cancer therapy which are based on scanning technology will require advanced beam diagnostics equipment. For a precise analysis of beam parameters we want to resolve time structures in the range of microseconds to nanoseconds. A prototype of an advanced beam monitor was developed by the University of Applied Sciences Wiener Neustadt and its research subsidiary Fotec in co-operation with CERN RD42, Ohio State University and the Jožef Stefan Institute in Ljubljana. The detector is based on polycrystalline Chemical Vapor Deposition (pCVD) diamond substrates and is equipped with readout electronics up to 2 GHz analog bandwidth. In this paper we present the design of the pCVD-detector system and results of tests performed in various particle accelerator based facilities. Measurements performed in clinical high energy photon beams agreed within 1.2% with results obtained by standard ionization chambers.

  4. Development of educational image databases and e-books for medical physics training.

    Science.gov (United States)

    Tabakov, S; Roberts, V C; Jonsson, B-A; Ljungberg, M; Lewis, C A; Wirestam, R; Strand, S-E; Lamm, I-L; Milano, F; Simmons, A; Deane, C; Goss, D; Aitken, V; Noel, A; Giraud, J-Y; Sherriff, S; Smith, P; Clarke, G; Almqvist, M; Jansson, T

    2005-09-01

    Medical physics education and training requires the use of extensive imaging material and specific explanations. These requirements provide an excellent background for application of e-Learning. The EU projects Consortia EMERALD and EMIT developed five volumes of such materials, now used in 65 countries. EMERALD developed e-Learning materials in three areas of medical physics (X-ray diagnostic radiology, nuclear medicine and radiotherapy). EMIT developed e-Learning materials in two further areas: ultrasound and magnetic resonance imaging. This paper describes the development of these e-Learning materials (consisting of e-books and educational image databases). The e-books include tasks helping studying of various equipment and methods. The text of these PDF e-books is hyperlinked with respective images. The e-books are used through the readers' own Internet browser. Each Image Database (IDB) includes a browser, which displays hundreds of images of equipment, block diagrams and graphs, image quality examples, artefacts, etc. Both the e-books and IDB are engraved on five separate CD-ROMs. Demo of these materials can be taken from www.emerald2.net.

  5. Safety problems with the use of medical equipment/devices

    NARCIS (Netherlands)

    Rademakers, C.

    2009-01-01

    In the past decennia medical technology has rapidly developed. Nowadays it plays an important role in all medical fields. It introduced technologic solutions for many medical problems and it definitely increased the possibilities in the medical field to increase the quality of life. However with

  6. Challenges in setting up quality control in diagnostic radiology ...

    African Journals Online (AJOL)

    Journal Home > Vol 24, No 4 (2015) >. Log in or ... Quality control (QC) on diagnostic radiology equipment form part of the fundamental requirements for the ... Inadequate cooperation by facilities management, lack of QC equipment and insufficient staff form the major challenges in setting up QC in the facilities under study.

  7. [Biochemical diagnostics of fatal opium intoxication].

    Science.gov (United States)

    Papyshev, I P; Astashkina, O G; Tuchik, E S; Nikolaev, B S; Cherniaev, A L

    2013-01-01

    Biochemical diagnostics of fatal opium intoxication remains a topical problem in forensic medical science and practice. We investigated materials obtained in the course of forensic medical expertise of the cases of fatal opium intoxication. The study revealed significant differences between myoglobin levels in blood, urine, myocardium, and skeletal muscles. The proposed approach to biochemical diagnostics of fatal opium intoxication enhances the accuracy and the level of evidence of expert conclusions.

  8. Phased implementation of AT and T PACS at Duke University Medical Center

    International Nuclear Information System (INIS)

    Stockbridge, C.; Ravin, C.E.

    1986-01-01

    ''Help me communicate more quickly and more effectively with referring clinicians''. This request was the driving behind the installation of the AT and T CommView System at Duke. The CommView System is a type of Digital Image Management System and Picture Archival Communication System whose chief purpose is to deliver interpolated diagnostic images to referring clinicians and attending physicians. The system acquires electronic images from modalities in a diagnostic imaging facility, stores these images in computer managed patient files and distributes these on demand over fiber optic cable to Display Consoles. The CommView System was designed at AT and T Bell Labs; it uses fiber optic ribbon cable between buildings fused to multistrand lightguide building cables to distribute images, typically around a medical center or campus at data transfer rates of 40 Mbps. This paper gives the rationale used in designing a start-up network and placing the initial equipment for a field of the AT and T CommView System in the Radiology Department of Duke University Medical Center

  9. Corruption in the Procurement of Pharmaceuticals and Medical Equipment in China: The Incentives Facing Multinationals, Domestic Firms and Hospital Officials

    OpenAIRE

    Rose-Ackerman, Susan; Tan, Yingqi

    2014-01-01

    Calls for reform of the Chinese healthcare system are voiced at the highest levels of the Chinese government, but reform cannot succeed unless policymakers confront the incentives for corruption built into the institutional structure of the healthcare system. Focusing on the markets for pharmaceuticals and medical equipment, this article isolates the special features of the Chinese healthcare system that are conducive to corruption. Without denying the responsibility of individual corporate r...

  10. Mapping of the radiation field of a mammography equipment using molybdenum and rhodium filters

    International Nuclear Information System (INIS)

    Barreira, Jacqueline S.; Campos, Daniela; Vivolo, Vitor

    2014-01-01

    The use of X rays for diagnostic radiology is very common and important to Medicine, including mammographic diagnosis focusing decreasing of the doses applied to the patients and preserving high quality of the diagnostic image. A quality control program of the irradiation systems it is very necessary. The Instruments Calibration Laboratory (LCI) of IPEN perform calibration in dosemeters used in radiation dosimetry (in diagnostic radiology) for many years. The objective of that paper is determining the point of greatest intensity of the beam issued by the mammography equipment. Exposures were made with filters Rhodium and Molybdenum. That mapping is important before applied a routine quality control program of the mammography equipment and the calibration of instruments in the diagnosis. (author)

  11. Improved Submariner Eyewear for Routine Wear and Emergency Equipment Use Underway

    Science.gov (United States)

    2010-01-15

    information. 2.0 DESCRIPTION Naval Submarine Medical Research Laboratory (NSMRL) is seeking information from the eyewear industry that will provide...Improved Submariner Eyewear for Routine Wear and Emergency Equipment Use Underway by Alison America, MA Wayne G. Horn, MD...Submariner Eyewear for Routine Wear and Emergency Equipment Use Underway 50818 Alison America, MA Wayne G. Horn, MD Naval Submarine Medical Research

  12. Meeting the challenges of managing substation equipment assets

    Energy Technology Data Exchange (ETDEWEB)

    Shaver, J. [CEA Technologies (Canada)

    2005-06-01

    Best practices for monitoring and assessing substation equipment are discussed. Scheduled time-based maintenance is the most common, but recent evidence indicates that despite it being the most expensive, it may not always identify potential failures. The author recommends developing decision-making tools that take into account obsolescence, reliability, safety and environmental issues, as well as operating, repair and carrying costs, as absolutely necessary for consistent and intelligent decision-making. Given the high cost of research, the author recommends developing such tools through pooling of skills and collaboration with other utilities, as the preferred way to develop best practices. The Life Cycle Management of Substation Equipment and Apparatus Interest Group of CEA Technologies Inc is one such group that was formed to help utilities facilitate their research and technology development endeavours. The group's current focus is on developing equipment diagnostics and life optimization through the development of validation tools for predicting remaining life and/or extending life. Brief descriptions of these, and other completed project are given. Completed projects described include developing tools for predicting remaining life of transformers, power connectors and disconnect switches, safety protocol for restoration of substations involved with fires/explosions, and compiling a critical review of diagnostic instruments designed to assess transformer conditions.

  13. Preliminary results of the analysis of the administered activities in diagnostic studies of nuclear medicine

    International Nuclear Information System (INIS)

    Lopez Bejerano, G.; Sed, L.J.

    2001-01-01

    The worldwide use of Nuclear Medicine diagnostic procedures and the tendency to its increment, infers an important exposure of the population to ionising radiation; it has motivated that the IAEA in the International Basic Safety Standards (BSS), emits recommendations for the establishment of guidance levels of activities administered to the patients in diagnostic procedures. Taking into account the above-mentioned and that in Cuba there exist 20 departments of Nuclear Medicine that in the majority possess equipment with more than 20 years of operation, which influences directly the medical exposure. A survey was designed and applied in 10 of these departments. The survey evaluates the compliance with the BSS requirements, and specifically, the activities administered to the patients in Nuclear Medicine diagnostic procedures are analysed. In the present work the obtained preliminary results of the statistical analysis carried out on the activity values used in Nuclear Medicine departments are presented, and comparisons made for a proposal of guidance levels for the national practice, which is compared with those recommended internationally. (author)

  14. 21 CFR 874.1925 - Toynbee diagnostic tube.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Toynbee diagnostic tube. 874.1925 Section 874.1925...) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Diagnostic Devices § 874.1925 Toynbee diagnostic tube. (a) Identification. The toynbee diagnostic tube is a listening device intended to determine the degree of openness of...

  15. Diagnostic interface problems on TFTR

    International Nuclear Information System (INIS)

    Goldfarb, S.

    1977-01-01

    Diagnostic equipment on TFTR has functional interfaces with many machine systems. Salient requirements include plasma access, environmental resistance to thermal, magnetic and radiation effects, automated data acquisition and controls, remote handling and personnel safety. Problems imposed by these requirements and the solutions being considered are described

  16. Diagnostics on Z (invited)

    International Nuclear Information System (INIS)

    Nash, T. J.; Derzon, M. S.; Chandler, G. A.; Fehl, D. L.; Leeper, R. J.; Porter, J. L.; Spielman, R. B.; Ruiz, C.; Cooper, G.; McGurn, J.

    2001-01-01

    The 100 ns, 20 MA pinch-driver Z is surrounded by an extensive set of diagnostics. There are nine radial lines of sight set at 12 o above horizontal and each of these may be equipped with up to five diagnostic ports. Instruments routinely fielded viewing the pinch from the side with these ports include x-ray diode arrays, photoconducting detector arrays, bolometers, transmission grating spectrometers, time-resolved x-ray pinhole cameras, x-ray crystal spectrometers, calorimeters, silicon photodiodes, and neutron detectors. A diagnostic package fielded on axis for viewing internal pinch radiation consists of nine lines of sight. This package accommodates virtually the same diagnostics as the radial ports. Other diagnostics not fielded on the axial or radial ports include current B-dot monitors, filtered x-ray scintillators coupled by fiber optics to streak cameras, streaked visible spectroscopy, velocity interferometric system for any reflector, bremsstrahlung cameras, and active shock breakout measurement of hohlraum temperature. The data acquisition system is capable of recording up to 500 channels and the data from each shot is available on the Internet. A major new diagnostic presently under construction is the BEAMLET backlighter. We will briefly describe each of these diagnostics and present some of the highest-quality data from them

  17. A study of radiological protection for women of reproductive age in diagnostic radiology. Questionnaire for medical radiation technologists

    International Nuclear Information System (INIS)

    Tsubone, Chie; Ban, Nobuhiko; Kai, Michiaki

    2005-01-01

    There has been great concern regarding the radiation protection for women of reproductive age when exposed to diagnostic radiation. The 10-day-rule proposed by the ICRP has not been recommended since 1983 because the risk to embryo and fetus within four weeks after menstruation may be small. However, some expects see that incomplete abandon of the 10-day-rule might cause confusion among the medical doctors and patients, and consequently unwarranted abortion happens. This paper surveyed the views of radiation technologies in hospitals and discussed how radiation exposure of women of reproductive age in medicine should be controlled. We found that the views to be 10-day-rule were spilt 50:50 and that radiation technologists do not necessarily think the 10-day-rule should be abandoned. Even the radiation technologists who are supposed to be able to explain to the patients the health risk following diagnostic exposure do not fully understand the risk involved. In conclusion, although a low-dose risk of diagnostic exposure should be sufficiently educated in order to obtain an exact understanding, the 10-day-rule may be useful in order to actually avoid any trouble in diagnostic radiology. (author)

  18. CAPITAL STRUCTURE ANALYSIS OF THE MEDICAL DIAGNOSTIC-CONSULTATIVE CENTERS IN VARNA (absolute indicators

    Directory of Open Access Journals (Sweden)

    Lyubomira Koeva-Dimitrova

    2016-08-01

    Full Text Available The capital structure analysis of medical institutions is related to the assessment of their financial sustainability. The degree of their financial sustainability indicates the extent to which the medical institution is exposed to financial risk. This financial risk is related to the use of foreign capital (debts, loans, etc. and it is defined as the probability of insolvency and possible bankruptcy due to the existence of debts which could not be repaid at some point in the foreseeable future. Objective: To analyze the capital structure of the medical diagnostic-consultative centers in Varna city and on this basis to assess their long-term solvency and existence of financial risk. Materials and Methods: The materials for the study are the published annual financial statements (up to 05. 01. 2016 in the Commercial Register for the period from year 2008 to 2014 of all MDCCs (Medical Diagnostic Consultative centers, registered in Varna - 9 in total. In the study are applied logical-mathematical methods (comparison, grouping, detail, graphical method; financial and accounting analysis (balance sheet analysis; analysis of absolute ratios for financial sustainability. Results: Upon analysis of the capital structure of MDCC's are studied the main absolute indicators characterizing the conditions for financial sustainability and the existence of financial risk regarding the solvency. A table represents the overall assessment of the degree of financial sustainability of the companies according to the type and structure of the fulfilled criteria. It was ascertained that for year 2014, DCC 3, 4, 5 and 8 have met all the conditions and according to them these hospitals have very high financial sustainability. DCC 7 has an average financial sustainability, DCC 1 and 2 are in a financial crisis and DCC 6 and 9 are facing bankruptcy. It must be emphasized that nearly half of the studied health care organizations (DCC 1, 2, 6 and 9 need urgent intervention by

  19. Application of noise analysis methods in nuclear reactor diagnostics

    International Nuclear Information System (INIS)

    Dach, K.

    1985-01-01

    By statistical evaluation of the fluctuation component of signals from selected detectors, noise diagnostics detects conditions of equipment which might later result in failure. The objective of early diagnostics is to detect the failed integrity of primary circuit components, failed detectors or anomalies of the thermohydraulic process. The commonest method of experimental data analysis is spectral analysis in the frequency range 0 to 50 Hz. Recently, expert diagnostic systems have been built based on artificial intelligence systems. Czechoslovakia participates in the experimental research of noise diagnostics in the context of the development of diagnostic assemblies for WWER-440 reactors. (M.D.)

  20. Adaptive Technology Application for Vibration-Based Diagnostics of Roller Bearings on Industrial Plants

    Directory of Open Access Journals (Sweden)

    Mironov Aleksey

    2014-09-01

    Full Text Available Roller bearings are widely used in equipment of different applications; therefore, the issues related to the assessment of bearing technical state and localization of bearing faults are quite important and relevant. The reason is that technical state of a bearing is a critical component, which determines efficiency of a mechanism or equipment. For bearings inspection and diagnostics, various methods of vibration-based diagnostics are used. The adaptive technology for vibration-based diagnostics developed in „D un D centrs” is an effective tool for evaluation of technical state of bearings in operation compared to the existing SKF method.

  1. The medical physicist in a nuclear medicine department

    International Nuclear Information System (INIS)

    Trujillo Z, F.E.; Gomez A, E.

    2007-01-01

    The diagnostic studies and therapeutic treatments carried out in a Nuclear Medicine department make use of radioactive material. For such a reason it becomes necessary to take a strict control in the reception, use and waste that are generated of the typical works inside the department. Also, work related with the quality control of the equipment dedicated to produce images and of those not image formers, need to carry out to guarantee its maximum performance; as well as quality of the diagnostic and of the therapy imparted in patients. Additionally its are needed to make originated works of the individual procedures to patient and of the acquisition of radioactive materials and removal of the waste or radioactive contaminations. Presently work the recommendations of the American College of Radiology (ACR), the European Federation of Organizations for Medical Physics (EFOMP) and of the Mexican Official Standards relating to the functions that should be observed in a Nuclear Medicine Department are exposed. The ACR and the EFOMP, conclude in their recommendations that the medical physicist fulfills with the suitable profile and likewise they describe in detail the actions and functions that he should supervise, to carry out, to document and to inform. (Author)

  2. [Development of Hospital Equipment Maintenance Information System].

    Science.gov (United States)

    Zhou, Zhixin

    2015-11-01

    Hospital equipment maintenance information system plays an important role in improving medical treatment quality and efficiency. By requirement analysis of hospital equipment maintenance, the system function diagram is drawed. According to analysis of input and output data, tables and reports in connection with equipment maintenance process, relationships between entity and attribute is found out, and E-R diagram is drawed and relational database table is established. Software development should meet actual process requirement of maintenance and have a friendly user interface and flexible operation. The software can analyze failure cause by statistical analysis.

  3. Myasthenia Gravis: Tests and Diagnostic Methods

    Science.gov (United States)

    ... Focus on MG Newsletter MG Quarterly Test & Diagnostic methods In addition to a complete medical and neurological ... How can I help? About MGFA Test & Diagnostic methods Treatment for MG FAQ's Upcoming Events 2018 MG ...

  4. Molecular diagnostics of neurodegenerative disorders

    Directory of Open Access Journals (Sweden)

    Megha eAgrawal

    2015-09-01

    Full Text Available Molecular diagnostics provide a powerful method to detect and diagnose various neurological diseases such as Alzheimer’s and Parkinson’s disease. The confirmation of such diagnosis allows early detection and subsequent medical counseling that help specific patients to undergo clinically important drug trials. This provides a medical pathway to have better insight of neurogenesis and eventual cure of the neurodegenerative diseases. In this short review, we present recent advances in molecular diagnostics especially biomarkers and imaging spectroscopy for neurological diseases. We describe advances made in Alzheimer’s disease, Parkinson’s disease, Amyotrophic lateral sclerosis and Huntington’s disease, and finally present a perspective on the future directions to provide a framework for further developments and refinements of molecular diagnostics to combat neurodegenerative disorders.

  5. Molecular diagnostics of neurodegenerative disorders.

    Science.gov (United States)

    Agrawal, Megha; Biswas, Abhijit

    2015-01-01

    Molecular diagnostics provide a powerful method to detect and diagnose various neurological diseases such as Alzheimer's and Parkinson's disease. The confirmation of such diagnosis allows early detection and subsequent medical counseling that help specific patients to undergo clinically important drug trials. This provides a medical pathway to have better insight of neurogenesis and eventual cure of the neurodegenerative diseases. In this short review, we present recent advances in molecular diagnostics especially biomarkers and imaging spectroscopy for neurological diseases. We describe advances made in Alzheimer's disease (AD), Parkinson's disease (PD), Amyotrophic lateral sclerosis (ALS) and Huntington's disease (HD), and finally present a perspective on the future directions to provide a framework for further developments and refinements of molecular diagnostics to combat neurodegenerative disorders.

  6. Medical Data Probabilistic Analysis by Optical Computing Methods

    Directory of Open Access Journals (Sweden)

    Alexander LARKIN

    2014-06-01

    Full Text Available The purpose of this article to show the laser coherent photonics methods can be use for classification of medical information. It is shown that the holography methods can be used not only for work with images. Holographic methods can be used for processing of information provided in the universal multi-parametric form. It is shown that along with the usual correlation algorithm enable to realize a number of algorithms of classification: searching for a precedent, Hamming distance measurement, Bayes probability algorithm, deterministic and “correspondence” algorithms. Significantly, that preserves all advantages of holographic method – speed, two-dimension, record-breaking high capacity of memory, flexibility of data processing and representation of result, high radiation resistance in comparison with electronic equipment. For example is presented the result of solving one of the problems of medical diagnostics - a forecast of organism state after mass traumatic lesions.

  7. Physical activity education in the undergraduate curricula of all UK medical schools: are tomorrow's doctors equipped to follow clinical guidelines?

    Science.gov (United States)

    Weiler, Richard; Chew, Stephen; Coombs, Ngaire; Hamer, Mark; Stamatakis, Emmanuel

    2012-11-01

    Physical activity (PA) is a cornerstone of disease prevention and treatment. There is, however, a considerable disparity between public health policy, clinical guidelines and the delivery of physical activity promotion within the National Health Service in the UK. If this is to be addressed in the battle against non-communicable diseases, it is vital that tomorrow's doctors understand the basic science and health benefits of physical activity. The aim of this study was to assess the provision of physical activity teaching content in the curricula of all medical schools in the UK. Our results, with responses from all UK medical schools, uncovered some alarming findings, showing that there is widespread omission of basic teaching elements, such as the Chief Medical Officer recommendations and guidance on physical activity. There is an urgent need for physical activity teaching to have dedicated time at medical schools, to equip tomorrow's doctors with the basic knowledge, confidence and skills to promote physical activity and follow numerous clinical guidelines that support physical activity promotion.

  8. Fluorescence spectroscopy for medical and environmental diagnostics

    International Nuclear Information System (INIS)

    Johansson, Jonas.

    1993-09-01

    Fluorescence spectroscopy can be used for diagnostics in medical and environmental applications. The many aspects of fluorescence emission are utilized to enhance the accuracy of the diagnosis. A fluorescence detection system, based on nitrogen laser or dye laser excitation and optical multichannel detection, was constructed, and fluorescence spectra from human malignant tumours of various origins, were recorded. Tumour demarcation was observed using exogenous chromophores, as well as the endogenous tissue fluorescence. In particular, δ-amino levulinic acid was found to provide very good tumour demarcation. A multi-colour imaging system capable of simultaneous recording of four fluorescence images at selected wavelengths, was developed. Examples of processed images, based on the four sub-images, are shown for malignant tumours. In addition, data from photodynamic treatment of human malignant tumours are presented. Autofluorescence spectra from excised pieces of human atherosclerotic aorta and atherosclerotic coronary segment were found to be different from those of non-diseased vessels. Furthermore, fluorescence decay curves from atherosclerotic samples were found to differ from those of non-diseased samples. It is concluded that both spectral and temporal information should be utilized to enhance the demarcation. Methods for obtaining fluorescence data free from interference from blood, with applications to in vivo laser angioplasty of atherosclerosis, are discussed. The optical multichannel system and the multi-colour imaging system were integrated with a remote sensing system, originally used for environmental measurements, to obtain fluorescence spectra as well as fluorescence images of plants at a distance of up to 100 m. The fluorescence data from plants subject to environmental stress or senescent plants were found to differ from those obtained from healthy vegetation. 359 refs

  9. Pocket book on setting techniques for medical imaging. X-ray diagnostics, angiography, CT, MRT. 4. rev. and enl. ed.; Taschenatlas Einstelltechnik. Roentgendiagnostik, Angiografie, CT, MRT

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, Torsten B.; Reif, Emil [Caritas-Krankenhaus, Dillingen/Saar (Germany)

    2009-07-01

    The pocketbook on setting techniques for medical imaging is concerned with the problem to prepare appropriate images for diagnostic purposes using modern high-technology instruments like x-ray diagnostics, angiography, computerized tomography and magnetic resonance tomography. The following issues are covered: Head, spinal column, upper extremities, lower extremities, thorax, gastrointestinal tract, intravenous organ examination, angiography, computerized tomography, NMR imaging.

  10. System for remote routine monitoring of power equipment at TPP and NPP

    International Nuclear Information System (INIS)

    Kantsedalov, V.G.; Samojlenko, V.P.; Doroshenko, V.A.

    1988-01-01

    A system for remote routine monitoring of TPP and NPP pipeline metals is described. The principal functional unit of the system is the unit of remote routine methods and techniques for studying and monitoring the metal and properties. The system is equipped with 5 types of routine monitoring equipment: robots, remote aggregated complexes, periodical diagnostic monitors, other means of metal diagnostics (endoscopes, introscopes). All current information enters the unit for estimating and forecasting the service life of power unit, where it is compared with the standard indices of reliability, duravility and efficiency. The system considered permits to reduce significantly or minimize the scope of works on metal monitoring during overhauls, increase intermonitoring and interrepairing compaigns to 8 years

  11. Complications in diagnostic imaging. 2. ed.

    International Nuclear Information System (INIS)

    Ansell, G.; Wilkins, R.A.; Medical Research Council, Harrow

    1987-01-01

    Thirty-seven chapters review various complications which may arise for patients and staff in medical diagnostic imaging. Five of these chapters are indexed separately covering topics on the complications of using radiopharmaceuticals, safety considerations in magnetic resonance imaging, radiation hazards of diagnostic radiology and medico-legal problems involving diagnostic radiology in both the UK and the USA. (UK)

  12. Survey of diagnostic radiology in the Republic of Ireland

    International Nuclear Information System (INIS)

    Cunningham, J.D.; Howett, D.; Hone, C.; Mulholland, C.

    1988-03-01

    This survey examined a number of aspects of the practice of diagnostic radiology in Ireland. These included the frequency of examinations, the gonadal and active bone marrow doses to patients, the genetically significant dose, the standard of design of x-ray rooms and of performance of equipment, and an inventory of equipment currently in use (author)

  13. Equipping medical graduates to address health systems challenges ...

    African Journals Online (AJOL)

    Methods: We defined HSR and strengthening competencies for medical graduates through a literature review and expert consultations. Learning outcomes in terms of knowledge, skill or attitude in the 64 module guides of the curriculum were compared with the competencies required. A survey of recent medical graduates ...

  14. Skylab medical technology utilization

    Science.gov (United States)

    Stonesifer, J. C.

    1974-01-01

    To perform the extensive medical experimentation on man in a long-term, zero-g environment, new medical measuring and monitoring equipment had to be developed, new techniques in training and operations were required, and new methods of collecting and analyzing the great amounts of medical data were developed. Examples of technology transfers to the public sector resulted from the development of new equipment, methods, techniques, and data. This paper describes several of the examples that stemmed directly from Skylab technology.

  15. FY 1999 report on the survey of the international joint research project on medical welfare equipment; 1999 nendo iryo fukushi kiki kokusai kyodo kenkyu jigyo chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    For the purpose of internationally cooperating in the R and D of medical welfare equipment, visits were paid to Australia and the U.S. to survey the related administration/research institutes/medical welfare facilities. Australia is a world leader of heart (transplant) operation, organ transplant, artificial middle ear, apneic relaxation equipment, ophthalmological equipment, bio-materials, etc. The country wants to positively promote the international cooperation with Japan because both countries are complementary to each other. Starting about 1999, the U.S. entered the age of competition of the R and D with the use of genome, and the post-genome age is already beginning there. A number of ventures are running for creation of new industry. As to the U.S. government's measures taken for subsidy, regulation, etc. toward new industry, the information could be obtained from the persons concerned. The impression of a tour of welfare facilities in the U.S. was that hardware/software are systematically prepared there, and the aged live bright and positive lives and enjoy lives. (NEDO)

  16. FY 1999 report on the survey of the international joint research project on medical welfare equipment; 1999 nendo iryo fukushi kiki kokusai kyodo kenkyu jigyo chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    For the purpose of internationally cooperating in the R and D of medical welfare equipment, visits were paid to Australia and the U.S. to survey the related administration/research institutes/medical welfare facilities. Australia is a world leader of heart (transplant) operation, organ transplant, artificial middle ear, apneic relaxation equipment, ophthalmological equipment, bio-materials, etc. The country wants to positively promote the international cooperation with Japan because both countries are complementary to each other. Starting about 1999, the U.S. entered the age of competition of the R and D with the use of genome, and the post-genome age is already beginning there. A number of ventures are running for creation of new industry. As to the U.S. government's measures taken for subsidy, regulation, etc. toward new industry, the information could be obtained from the persons concerned. The impression of a tour of welfare facilities in the U.S. was that hardware/software are systematically prepared there, and the aged live bright and positive lives and enjoy lives. (NEDO)

  17. Report on the FY 1999 R and D on medical welfare equipment technology. Comprehensive survey of welfare equipment; 1999 nendo iryo fukushi kiki gijutsu kenkyu kaihatsu hokokusho. Fukushi kiki sozo chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    The paper made it clear what kinds of R and D will be required for equipment which supports action of aged handicapped persons in daily life and social life in the following three fields: support of walking and movement in daily life, grasp of action and life situation, and support of operation of life information. The purpose of the survey is to intensify the results as the data for effective promotion of the commercialization of the welfare equipment/system which are great in safety and convenience, low-priced, and high-efficient making use of high-tech industrial technology in the project for the R and D of medical welfare equipment technology promoted by NEDO. Therefore, the item for survey in the important field was made 'the comprehensive survey on the project of the R and D on welfare technology such as life supporting robot systems.' The survey was made on the following: (1) 'life support robot' which supports walking and simple motion in daily life of aged people, (2) 'life support information terminal' which enables regional communication and is easy for aged people to use, (3) 'monitoring system for at-home daily activities and life situation' using sensor integrated into electric home appliances, etc. (NEDO)

  18. Report on the FY 1999 R and D on medical welfare equipment technology. Comprehensive survey of welfare equipment; 1999 nendo iryo fukushi kiki gijutsu kenkyu kaihatsu hokokusho. Fukushi kiki sozo chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    The paper made it clear what kinds of R and D will be required for equipment which supports action of aged handicapped persons in daily life and social life in the following three fields: support of walking and movement in daily life, grasp of action and life situation, and support of operation of life information. The purpose of the survey is to intensify the results as the data for effective promotion of the commercialization of the welfare equipment/system which are great in safety and convenience, low-priced, and high-efficient making use of high-tech industrial technology in the project for the R and D of medical welfare equipment technology promoted by NEDO. Therefore, the item for survey in the important field was made 'the comprehensive survey on the project of the R and D on welfare technology such as life supporting robot systems.' The survey was made on the following: (1) 'life support robot' which supports walking and simple motion in daily life of aged people, (2) 'life support information terminal' which enables regional communication and is easy for aged people to use, (3) 'monitoring system for at-home daily activities and life situation' using sensor integrated into electric home appliances, etc. (NEDO)

  19. Quality Control in Diagnostic Radiology: Experiences and Achievements

    International Nuclear Information System (INIS)

    Mohd Khalid Matori; Husaini Salleh; Muhammad Jamal Md Isa

    2015-01-01

    Malaysian Nuclear Agency through its Medical Physics Group has been providing Quality Control (QC) services for medical X-ray apparatus used in diagnostic radiology to private clinics and hospitals since the year 1997. The Medical Physics Groups services is endorsed by the Malaysian Ministry Of Health (MOH) and is in accordance with the Malaysian Standard MS 838 and the Atomic Energy Licensing Act, 1984. Until today, the scopes of testing services also include all types of medical x-ray apparatus. The quality control (QC) in diagnostic radiology is considered as part of quality assurance program which provide accurate diagnostic information at the lowest cost and the least exposure of the patients to radiation. Many experience and obstacles were faced by Medical Physics Group. This paper will discuss the experiences and achievements of providing QC service from early stage until now so that it can be shared by the citizens of the Malaysian Nuclear Agency. The results of quality assurance inspection of all types of X-ray apparatus for medical conducted by Agency Nuclear Malaysia will be presented in brief. (author)

  20. 21 CFR 886.1390 - Flexible diagnostic Fresnel lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Flexible diagnostic Fresnel lens. 886.1390 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1390 Flexible diagnostic Fresnel lens. (a) Identification. A flexible diagnostic Fresnel lens is a device that is a very thin lens which has...