WorldWideScience

Sample records for medical device evaluation

  1. Classification and evaluation of medical devices

    Directory of Open Access Journals (Sweden)

    Edina Vranić

    2003-05-01

    Full Text Available Medical devices and medical disposables contribute significantly to the quality and effectiveness of the health care system. It is necessary to commit scientifically sound regulatory environment that will provide consumers with the best medical care. This includes continued services to small manufacturers, readily available guidance on FDA requirements, predictable and reasonable response times on applications for marketing, and equitable enforcement. But in the public interest, this commitment to the industry must be coupled with a reciprocal commitment: that medical device firms will meet high standards in the design, manufacture, and evaluation of their products. The protections afforded our consumer, and the benefits provided the medical device industry, cannot be underestimated.

  2. Risk evaluation of medical and industrial radiation devices

    International Nuclear Information System (INIS)

    Jones, E.D.; Cunningham, R.E.; Rathbun, P.A.

    1994-03-01

    In 1991, the NRC, Division of Industrial and Medical Nuclear Safety, began a program to evaluate the use of probabilistic risk assessment (PRA) in regulating medical devices. This program represents an initial step in an overall plant to evaluate the use of PRA in regulating the use of nuclear by-product materials. The NRC envisioned that the use of risk analysis techniques could assist staff in ensuring that the regulatory approach was standardized, understandable, and effective. Traditional methods of assessing risk in nuclear power plants may be inappropriate to use in assessing the use of by-product devices. The approaches used in assessing nuclear reactor risks are equipment-oriented. Secondary attention is paid to the human component, for the most part after critical system failure events have been identified. This paper describes the risk methodology developed by Lawrence Livermore National Laboratory (LLNL), initially intended to assess risks associated with the use of the Gamma Knife, a gamma stereotactic radiosurgical device. For relatively new medical devices such as the Gamma Knife, the challenge is to perform a risk analysis with very little quantitative data but with an important human factor component. The method described below provides a basic approach for identifying the most likely risk contributors and evaluating their relative importance. The risk analysis approach developed for the Gamma Knife and described in this paper should be applicable to a broader class of devices in which the human interaction with the device is a prominent factor. In this sense, the method could be a prototypical model of nuclear medical or industrial device risk analysis

  3. Evaluating and Predicting Patient Safety for Medical Devices With Integral Information Technology

    Science.gov (United States)

    2005-01-01

    323 Evaluating and Predicting Patient Safety for Medical Devices with Integral Information Technology Jiajie Zhang, Vimla L. Patel, Todd R...errors are due to inappropriate designs for user interactions, rather than mechanical failures. Evaluating and predicting patient safety in medical ...the users on the identified trouble spots in the devices. We developed two methods for evaluating and predicting patient safety in medical devices

  4. Safety evaluation in the development of medical devices and combination products

    CERN Document Server

    Gad, Shayne C

    2008-01-01

    Capturing the growth of the global medical device market in recent years, this practical new guide is essential for all who are responsible for ensuring safety in the use and manufacture of medical devices. It has been extensively updated to reflect significant advances, incorporating combination products and helpful case examples of current real-life problems in the field.The Third Edition explores these key current trends:global device marketscontinually advancing technologythe increasing harmonization of device safety regulation worldwideEach aspect of safety evaluation is considered in ter

  5. Inhaled medication for asthma management: evaluation of how asthma patients, medical students, and doctors use the different devices

    Directory of Open Access Journals (Sweden)

    Muniz Janaína Barbosa

    2003-01-01

    Full Text Available Asthma results from a combination of three essential features: airflow obstruction, hyperresponsiveness of airways to endogenous or exogenous stimuli and inflammation. Inadequacy of the techniques to use different inhalation devices is one of the causes of therapeutic failure. The main purpose of this study was to evaluate how 20 medical students, 36 resident physicians of Internal Medicine/Pediatrics, and 40 asthma patients used three devices for inhalation therapy containing placebo. All patients were followed at the Pulmonary Outpatient Service of Botucatu Medical School and had been using inhaled medication for at least six months. The following devices were evaluated: metered dose inhalers (MDI, dry powder inhalers (DPI, and MDI attached to a spacer device. A single observer applied a protocol containing the main steps necessary to obtain a good inhaler technique to follow and grade the use of different devices. Health care professionals tested all three devices and patients tested only the device being used on their management. MDI was the device best known by doctors and patients. MDI use was associated with errors related to the coordination between inspiration and device activation. Failure to exhale completely before inhalation of the powder was the most frequent error observed with DPI use. In summary, patients did not receive precise instruction on how to use inhaled medication and health care professionals were not well prepared to adequately teach their patients.

  6. Risk assessment of medical devices: evaluation of microbiological and toxicological safety

    International Nuclear Information System (INIS)

    Dorpema, J.W.

    1995-01-01

    Safety assessment of medical devices includes sterilization and biological evaluation or biocompatability testing. Sterilization by ETO gas is criticised for their carcinogenic potency or even banned. Mutual acceptance of biological evaluation test results is promoted by a laboratory accreditation and qualification program. (Author)

  7. Human Factors and Medical Devices

    International Nuclear Information System (INIS)

    Dick Sawyer

    1998-01-01

    Medical device hardware- and software-driven user interfaces should be designed to minimize the likelihood of use-related errors and their consequences. The role of design-induced errors in medical device incidents is attracting widespread attention. The U.S. Food and Drug Administration (FDA) is fully cognizant that human factors engineering is critical to the design of safe medical devices, and user interface design is receiving substantial attention by the agency. Companies are paying more attention to the impact of device design, including user instructions, upon the performance of those health professionals and lay users who operate medical devices. Concurrently, the FDA is monitoring human factors issues in its site inspections, premarket device approvals, and postmarket incident evaluations. Overall, the outlook for improved designs and safer device operation is bright

  8. [Industry regulation and its relationship to the rapid marketing of medical devices].

    Science.gov (United States)

    Matsuoka, Atsuko

    2012-01-01

    In the market of medical devices, non-Japanese products hold a large part even in Japan. To overcome this situation, the Japanese government has been announcing policies to encourage the medical devices industry, such as the 5-year strategy for medical innovation (June 6, 2012). The Division of Medical Devices has been contributing to rapid marketing of medical devices by working out the standards for approval review and accreditation of medical devices, guidances on evaluation of medical devices with emerging technology, and test methods for biological safety evaluation of medical devices, as a part of practice in the field of regulatory science. The recent outcomes are 822 standards of accreditation for Class II medical devices, 14 guidances on safety evaluation of medical devices with emerging technology, and the revised test methods for biological safety evaluation (MHLW Notification by Director, OMDE, Yakushokuki-hatsu 0301 No. 20 "Basic Principles of Biological Safety Evaluation Required for Application for Approval to Market Medical Devices").

  9. Contextual inquiry for medical device design

    CERN Document Server

    Privitera, Mary Beth

    2015-01-01

    Contextual Inquiry for Medical Device Design helps users understand the everyday use of medical devices and the way their usage supports the development of better products and increased market acceptance. The text explains the concept of contextual inquiry using real-life examples to illustrate its application. Case studies provide a frame of reference on how contextual inquiry is successfully used during product design, ultimately producing safer, improved medical devices. Presents the ways contextual inquiry can be used to inform the evaluation and business case of technologyHelps users

  10. Utilizing national and international registries to enhance pre-market medical device regulatory evaluation.

    Science.gov (United States)

    Yue, Lilly Q; Campbell, Gregory; Lu, Nelson; Xu, Yunling; Zuckerman, Bram

    2016-01-01

    Regulatory decisions are made based on the assessment of risk and benefit of medical devices at the time of pre-market approval and subsequently, when post-market risk-benefit balance needs reevaluation. Such assessments depend on scientific evidence obtained from pre-market studies, post-approval studies, post-market surveillance studies, patient perspective information, as well as other real world data such as national and international registries. Such registries provide real world evidence and are playing a more and more important role in enhancing the safety and effectiveness evaluation of medical devices. While these registries provide large quantities of data reflecting real world practice and can potentially reduce the cost of clinical trials, challenges arise concerning (1) data quality adequate for regulatory decision-making, (2) bias introduced at every stage and aspect of study, (3) scientific validity of study designs, and (4) reliability and interpretability of study results. This article will discuss related statistical and regulatory challenges and opportunities with examples encountered in medical device regulatory reviews.

  11. Practice of Regulatory Science (Development of Medical Devices).

    Science.gov (United States)

    Niimi, Shingo

    2017-01-01

    Prototypes of medical devices are made in accordance with the needs of clinical practice, and for systems required during the initial process of medical device development for new surgical practices. Verification of whether these prototypes produce the intended performance specifications is conducted using basic tests such as mechanical and animal tests. The prototypes are then improved and modified until satisfactory results are obtained. After a prototype passes through a clinical trial process similar to that for new drugs, application for approval is made. In the approval application process, medical devices are divided into new, improved, and generic types. Reviewers judge the validity of intended use, indications, operation procedures, and precautions, and in addition evaluate the balance between risk and benefit in terms of efficacy and safety. Other characteristics of medical devices are the need for the user to attain proficiency in usage techniques to ensure efficacy and safety, and the existence of a variety of medical devices for which assessment strategies differ, including differences in impact on the body in cases in which a physical burden to the body or failure of a medical device develops. Regulatory science of medical devices involves prediction, judgment, and evaluation of efficacy, safety, and quality, from which data result which can become indices in the development stages from design to application for approval. A reduction in the number of animals used for testing, improvement in efficiency, reduction of the necessity for clinical trials, etc. are expected through rational setting of evaluation items.

  12. Medical device market in China.

    Science.gov (United States)

    Boyer, Philip; Morshed, Bashir I; Mussivand, Tofy

    2015-06-01

    With China's growing old-age population and economic presence on the international stage, it has become important to evaluate its domestic and foreign market contribution to medical devices. Medical devices are instruments or apparatuses used in the prevention, rehabilitation, treatment, or knowledge generation with respect to disease or other abnormal conditions. This article provides information drawn from recent publications to describe the current state of the Chinese domestic market for medical devices and to define opportunities for foreign investment potential therein. Recent healthcare reforms implemented to meet rising demand due to an aging and migrating population are having a positive effect on market growth-a global market with a projected growth of 15% per year over the next decade. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  13. [Ethic review on clinical experiments of medical devices in medical institutions].

    Science.gov (United States)

    Shuai, Wanjun; Chao, Yong; Wang, Ning; Xu, Shining

    2011-07-01

    Clinical experiments are always used to evaluate the safety and validity of medical devices. The experiments have two types of clinical trying and testing. Ethic review must be done by the ethics committee of the medical department with the qualification of clinical research, and the approval must be made before the experiments. In order to ensure the safety and validity of clinical experiments of medical devices in medical institutions, the contents, process and approval criterions of the ethic review were analyzed and discussed.

  14. PRE-MARKET CLINICAL EVALUATIONS OF INNOVATIVE HIGH-RISK MEDICAL DEVICES IN EUROPE

    DEFF Research Database (Denmark)

    Hulstaert, F.; Neyt, M.; Vinck, I.

    2012-01-01

    data are available? We studied the premarket clinical evaluation of innovative high-risk medical devices in Europe compared with the US, and with medicines, where appropriate. Methods: The literature and regulatory documents were checked. Representatives from industry, Competent Authorities, Notified...... of premarket trials in Europe and number of patients exposed, but failed as this information is not made public. Furthermore, the Helsinki Declaration is not followed with respect to the registration and publication of premarket trials. Conclusions: For innovative high-risk devices, new EU legislation should...

  15. Medical Device Safety

    Science.gov (United States)

    A medical device is any product used to diagnose, cure, or treat a condition, or to prevent disease. They ... may need one in a hospital. To use medical devices safely Know how your device works. Keep ...

  16. Implantable electronic medical devices

    CERN Document Server

    Fitzpatrick, Dennis

    2014-01-01

    Implantable Electronic Medical Devices provides a thorough review of the application of implantable devices, illustrating the techniques currently being used together with overviews of the latest commercially available medical devices. This book provides an overview of the design of medical devices and is a reference on existing medical devices. The book groups devices with similar functionality into distinct chapters, looking at the latest design ideas and techniques in each area, including retinal implants, glucose biosensors, cochlear implants, pacemakers, electrical stimulation t

  17. Implantable Medical Devices

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Implantable Medical Devices Updated:Sep 16,2016 For Rhythm Control ... a Heart Attack Introduction Medications Surgical Procedures Implantable Medical Devices • Life After a Heart Attack • Heart Attack ...

  18. [Discussion on Quality Evaluation Method of Medical Device During Life-Cycle in Operation Based on the Analytic Hierarchy Process].

    Science.gov (United States)

    Zheng, Caixian; Zheng, Kun; Shen, Yunming; Wu, Yunyun

    2016-01-01

    The content related to the quality during life-cycle in operation of medical device includes daily use, repair volume, preventive maintenance, quality control and adverse event monitoring. In view of this, the article aims at discussion on the quality evaluation method of medical devices during their life cycle in operation based on the Analytic Hierarchy Process (AHP). The presented method is proved to be effective by evaluating patient monitors as example. The method presented in can promote and guide the device quality control work, and it can provide valuable inputs to decisions about purchase of new device.

  19. Health economic evaluations of medical devices in the People's Republic of China: A systematic literature review.

    Science.gov (United States)

    Zhang, Rongrong; Modaresi, Farhang; Borisenko, Oleg

    2015-01-01

    The objective of this study is to identify and review the methodological quality of health economic evaluations of medical devices performed in the People's Republic of China. To our knowledge, no such investigations have been performed to date. A systematic literature review involving searches of Medline, Medline In-Process, the National Health Service Economic Evaluation Database, the Cost-Effectiveness Analysis Registry of the Tufts Medical Center, and the Wanfang Database was performed. The search spanned the period from 1990 to 2013. Studies on health economic evaluations of medical devices, in-vitro diagnostics, procedures, and the use of medical devices in Chinese health care settings were included. Full-text articles and conference abstracts in English and Chinese were included. Fifty-seven publications were included, 26 (46%) of which were in English and 31 (54%) of which were in Chinese. The included publications covered a wide range of clinical areas, such as surgery (n=23, 40%), screening (n=9, 16%), imaging use (n=6, 11%), kidney intervention (n=4, 7%), and nine other technological areas. Most of the studies (n=31, 54%) were cost analyses. Among the others, 13 (50%) studies used modeling, and another 13 (50%) were within-trial evaluations. Among studies that used modeling, eleven (85%) conducted sensitivity analyses, six of which had one-way sensitivity analysis, whereas one conducted both one-way and two-way sensitivity analyses; four of these eleven modeling-based analyses included probabilistic sensitivity analyses. The incremental cost-effectiveness ratio was reported in ten (18%) studies, eight of which were screening studies. The remaining two modeling studies were in areas of imaging and oncology. This study indicates that there are major limitations and deficiencies in the health economic evaluations on medical devices performed in the People's Republic of China. Further efforts are required from different stakeholders - academic, governmental

  20. Strategy on biological evaluation for biodegradable/absorbable materials and medical devices.

    Science.gov (United States)

    Liu, Chenghu; Luo, Hongyu; Wan, Min; Hou, Li; Wang, Xin; Shi, Yanping

    2018-01-01

    During the last two decades, biodegradable/absorbable materials which have many benefits over conventional implants are being sought in clinical practices. However, to date, it still remains obscure for us to perform full physic-chemical characterization and biological risk assessment for these materials and related devices due to their complex design and coherent processing. In this review, based on the art of knowledge for biodegradable/absorbable materials and biological risk assessment, we demonstrated some promising strategies to establish and improve the current biological evaluation systems for these biodegradable/absorbable materials and related medical devices.

  1. INTERFACE ELECTRONIC MEDICAL CARD ON MOBILE DEVICE

    Directory of Open Access Journals (Sweden)

    Y. L. Nechyporenko

    2013-05-01

    Full Text Available The concept designed by electronic medical card for heterogeneous environment of medical information systems at various levels. Appropriate model and technical solution. Done evaluating operating systems for mobile devices. Designed and produced by the project mobile application on Android OS as an electronic medical record on a Tablet PC Acer.

  2. 75 FR 6401 - Medical Devices Regulated by the Center for Biologics Evaluation and Research; Availability of...

    Science.gov (United States)

    2010-02-09

    ... Biologics Evaluation and Research (HFM-17), Food and Drug Administration, suite 200N, 1401 Rockville Pike... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2009-M-0513] Medical Devices Regulated by the Center for Biologics Evaluation and Research; Availability of Summaries...

  3. Class 1 devices case studies in medical devices design

    CERN Document Server

    Ogrodnik, Peter J

    2014-01-01

    The Case Studies in Medical Devices Design series consists of practical, applied case studies relating to medical device design in industry. These titles complement Ogrodnik's Medical Device Design and will assist engineers with applying the theory in practice. The case studies presented directly relate to Class I, Class IIa, Class IIb and Class III medical devices. Designers and companies who wish to extend their knowledge in a specific discipline related to their respective class of operation will find any or all of these titles a great addition to their library. Class 1 Devices is a companion text to Medical Devices Design: Innovation from Concept to Market. The intention of this book, and its sister books in the series, is to support the concepts presented in Medical Devices Design through case studies. In the context of this book the case studies consider Class I (EU) and 510(k) exempt (FDA) . This book covers classifications, the conceptual and embodiment phase, plus design from idea to PDS. These title...

  4. Case outsourcing medical device reprocessing.

    Science.gov (United States)

    Haley, Deborah

    2004-04-01

    IN THE INTEREST OF SAVING MONEY, many hospitals are considering extending the life of some single-use medical devices by using medical device reprocessing programs. FACILITIES OFTEN LACK the resources required to meet the US Food and Drug Administration's tough quality assurance standards. BY OUTSOURCING, hospitals can reap the benefits of medical device reprocessing without assuming additional staffing and compliance burdens. OUTSOURCING enables hospitals to implement a medical device reprocessing program quickly, with no capital investment and minimal effort.

  5. Medical device-related pressure ulcers

    Directory of Open Access Journals (Sweden)

    Black JM

    2016-08-01

    Full Text Available Joyce M Black,1 Peggy Kalowes2 1Adult Health and Illness Department, College of Nursing, University of Nebraska Medical Center, Omaha, NE, 2Nursing Research and Innovation, Long Beach Memorial Miller Children’s & Women’s Hospital, Long Beach, CA, USA Abstract: Pressure ulcers from medical devices are common and can cause significant morbidity in patients of all ages. These pressure ulcers appear in the shape of the device and are most often found from the use of oxygen delivery devices. A hospital program designed to reduce the number of pressure ulcers from medical devices was successful. The program involved the development of a team that focused on skin, the results were then published for the staff to track their performance, and it was found that using foam dressings helped reduce the pressure from the device. The incidence of ulcers from medical devices has remained at zero at this hospital since this program was implemented. Keywords: pressure ulcer, medical device related

  6. [Medical Devices Law for pain therapists].

    Science.gov (United States)

    Regner, M; Sabatowski, R

    2016-08-01

    Medical Devices Law is a relatively new legal system, which has replaced the Medical Devices Regulations still well-known in Germany. German Medical Devices Law is based on European directives, which are, in turn, incorporated into national law by the Medical Devices Act. The Medical Devices Act is a framework law and covers a number of regulations that address specific topics within Medical Devices Law. In turn, in individual regulations, reference is made to guidelines, recommendations, etc. from other sources that provide detailed technical information on specific topics. Medical Devices Law is a very complex legal system, which needs to be permanently observed due to constant updating and adjustment. In the current article, the design and the structure of the system will be described, but special emphasis will be laid on important problem areas that need to be considered when applying and operating medical products, in this case by pain therapists in particular.

  7. 77 FR 8260 - Agency Information Collection Activities; Proposed Collection; Comment Request; Medical Device...

    Science.gov (United States)

    2012-02-14

    ... will be used to evaluate risks associated with medical devices which will enable FDA to take...] Agency Information Collection Activities; Proposed Collection; Comment Request; Medical Device Reporting... comment in response to the notice. This notice solicits comments on medical device reporting (MDR...

  8. Medical device software: defining key terms.

    Science.gov (United States)

    Pashkov, Vitalii; Gutorova, Nataliya; Harkusha, Andrii

    one of the areas of significant growth in medical devices has been the role of software - as an integral component of a medical device, as a standalone device and more recently as applications on mobile devices. The risk related to a malfunction of the standalone software used within healthcare is in itself not a criterion for its qualification or not as a medical device. It is therefore, necessary to clarify some criteria for the qualification of stand-alone software as medical devices Materials and methods: Ukrainian, European Union, United States of America legislation, Guidelines developed by European Commission and Food and Drug Administration's, recommendations represented by international voluntary group and scientific works. This article is based on dialectical, comparative, analytic, synthetic and comprehensive research methods. the legal regulation of software which is used for medical purpose in Ukraine limited to one definition. In European Union and United States of America were developed and applying special guidelines that help developers, manufactures and end users to difference software on types standing on medical purpose criteria. Software becomes more and more incorporated into medical devices. Developers and manufacturers may not have initially appreciated potential risks to patients and users such situation could have dangerous results for patients or users. It is necessary to develop and adopt the legislation that will intend to define the criteria for the qualification of medical device software and the application of the classification criteria to such software, provide some illustrative examples and step by step recommendations to qualify software as medical device.

  9. Medical devices regulations, standards and practices

    CERN Document Server

    Ramakrishna, Seeram; Wang, Charlene

    2015-01-01

    Medical Devices and Regulations: Standards and Practices will shed light on the importance of regulations and standards among all stakeholders, bioengineering designers, biomaterial scientists and researchers to enable development of future medical devices. Based on the authors' practical experience, this book provides a concise, practical guide on key issues and processes in developing new medical devices to meet international regulatory requirements and standards. Provides readers with a global perspective on medical device regulationsConcise and comprehensive information on how to desig

  10. 21 CFR 892.2040 - Medical image hardcopy device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical image hardcopy device. 892.2040 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2040 Medical image hardcopy device. (a) Identification. A medical image hardcopy device is a device that produces a visible printed record of a medical...

  11. [Consideration of Mobile Medical Device Regulation].

    Science.gov (United States)

    Peng, Liang; Yang, Pengfei; He, Weigang

    2015-07-01

    The regulation of mobile medical devices is one of the hot topics in the industry now. The definition, regulation scope and requirements, potential risks of mobile medical devices were analyzed and discussed based on mobile computing techniques and the FDA guidance of mobile medical applications. The regulation work of mobile medical devices in China needs to adopt the risk-based method.

  12. Optical tests for using smartphones inside medical devices

    Science.gov (United States)

    Bernat, Amir S.; Acobas, Jennifer K.; Phang, Ye Shang; Hassan, David; Bolton, Frank J.; Levitz, David

    2018-02-01

    Smartphones are currently used in many medical applications and are more frequently being integrated into medical imaging devices. The regulatory requirements in existence today however, particularly the standardization of smartphone imaging through validation and verification testing, only partially cover imaging characteristics with a smartphone. Specifically, it has been shown that smartphone camera specifications are of sufficient quality for medical imaging, and there are devices which comply with the FDA's regulatory requirements for a medical device such as a device's field of view, direction of viewing and optical resolution and optical distortion. However, these regulatory requirements do not call specifically for color testing. Images of the same object using automatic settings or different light sources can show different color composition. Experimental results showing such differences are presented. Under some circumstances, such differences in color composition could potentially lead to incorrect diagnoses. It is therefore critical to control the smartphone camera and illumination parameters properly. This paper examines different smartphone camera settings that affect image quality and color composition. To test and select the correct settings, a test methodology is proposed. It aims at evaluating and testing image color correctness and white balance settings for mobile phones and LED light sources. Emphasis is placed on color consistency and deviation from gray values, specifically by evaluating the ΔC values based on the CIEL*a*b* color space. Results show that such standardization minimizes differences in color composition and thus could reduce the risk of a wrong diagnosis.

  13. Surgical tools and medical devices

    CERN Document Server

    Jackson, Mark

    2016-01-01

    This new edition presents information and knowledge on the field of biomedical devices and surgical tools. The authors look at the interactions between nanotechnology, nanomaterials, design, modeling, and tools for surgical and dental applications, as well as how nanostructured surfaces can be created for the purposes of improving cell adhesion between medical devices and the human body. Each original chapter is revised in this second edition and describes developments in coatings for heart valves, stents, hip and knee joints, cardiovascular devices, orthodontic applications, and regenerative materials such as bone substitutes. There are also 8 new chapters that address: Microvascular anastomoses Inhaler devices used for pulmonary delivery of medical aerosols Surface modification of interference screws Biomechanics of the mandible (a detailed case study) Safety and medical devices The synthesis of nanostructured material Delivery of anticancer molecules using carbon nanotubes Nano and micro coatings for medic...

  14. Medical device development.

    Science.gov (United States)

    Panescu, Dorin

    2009-01-01

    The development of a successful medical product requires not only engineering design efforts, but also clinical, regulatory, marketing and business expertise. This paper reviews items related to the process of designing medical devices. It discusses the steps required to take a medical product idea from concept, through development, verification and validation, regulatory approvals and market release.

  15. [Regulatory Program for Medical Devices in Cuba: experiences and current challenges].

    Science.gov (United States)

    Pereira, Dulce María Martínez; Rodríguez, Yadira Álvarez; Valdés, Yamila Cedeño; Ribas, Silvia Delgado

    2016-05-01

    Regulatory control of medical devices in Cuba is conducted through a system based on the Regulatory Program for Medical Devices as a way to ensure the safety, efficacy, and effectiveness of these technologies, which are in use by the National Health System. This program was launched in 1992, when the Regulations for State Evaluation and Registration of Medical Devices were approved. Its successive stages and the merging of regulatory activities for drugs and medical equipment have meant progress toward stronger, more transparent strategies and greater control of industry and the National Health System. Throughout its course the Cuban program has met with challenges and difficulties that it has addressed by drawing on its own experiences. During the new period, the greatest challenges revolve around ensuring that regulatory systems incorporate scientific evaluation, risk levels, maximum rigor through the use of technical standards, and the implementation of international recommendations, together with the application of the ISO 13485 certification scheme, enhanced market monitoring, and classification of medical devices in accordance with their relevance to the country's national health policies. From the regional standpoint, the greatest challenge lies in working toward regulatory convergence. The Collaborating Centre for the Regulation of Health Technologies will support the proposed regulatory strategy and established regional priorities, in particular in connection with the implementation of actions involving medical devices.

  16. Advancing medical device innovation through collaboration and coordination of structured data capture pilots: Report from the Medical Device Epidemiology Network (MDEpiNet) Specific, Measurable, Achievable, Results-Oriented, Time Bound (SMART) Think Tank.

    Science.gov (United States)

    Reed, Terrie L; Drozda, Joseph P; Baskin, Kevin M; Tcheng, James; Conway, Karen; Wilson, Natalia; Marinac-Dabic, Danica; Heise, Theodore; Krucoff, Mitchell W

    2017-12-01

    The Medical Device Epidemiology Network (MDEpiNet) is a public private partnership (PPP) that provides a platform for collaboration on medical device evaluation and depth of expertise for supporting pilots to capture, exchange and use device information for improving device safety and protecting public health. The MDEpiNet SMART Think Tank, held in February, 2013, sought to engage expert stakeholders who were committed to improving the capture of device data, including Unique Device Identification (UDI), in key electronic health information. Prior to the Think Tank there was limited collaboration among stakeholders beyond a few single health care organizations engaged in electronic capture and exchange of device data. The Think Tank resulted in what has become two sustainable multi-stakeholder device data capture initiatives, BUILD and VANGUARD. These initiatives continue to mature within the MDEpiNet PPP structure and are well aligned with the goals outlined in recent FDA-initiated National Medical Device Planning Board and Medical Device Registry Task Force white papers as well as the vision for the National Evaluation System for health Technology.%. Published by Elsevier Inc.

  17. Value-based purchasing of medical devices.

    Science.gov (United States)

    Obremskey, William T; Dail, Teresa; Jahangir, A Alex

    2012-04-01

    Health care in the United States is known for its continued innovation and production of new devices and techniques. While the intention of these devices is to improve the delivery and outcome of patient care, they do not always achieve this goal. As new technologies enter the market, hospitals and physicians must determine which of these new devices to incorporate into practice, and it is important these devices bring value to patient care. We provide a model of a physician-engaged process to decrease cost and increase review of physician preference items. We describe the challenges, implementation, and outcomes of cost reduction and product stabilization of a value-based process for purchasing medical devices at a major academic medical center. We implemented a physician-driven committee that standardized and utilized evidence-based, clinically sound, and financially responsible methods for introducing or consolidating new supplies, devices, and technology for patient care. This committee worked with institutional finance and administrative leaders to accomplish its goals. Utilizing this physician-driven committee, we provided access to new products, standardized some products, decreased costs of physician preference items 11% to 26% across service lines, and achieved savings of greater than $8 million per year. The implementation of a facility-based technology assessment committee that critically evaluates new technology can decrease hospital costs on implants and standardize some product lines.

  18. Pre-market clinical evaluations of innovative high-risk medical devices in Europe.

    Science.gov (United States)

    Hulstaert, Frank; Neyt, Mattias; Vinck, Imgard; Stordeur, Sabine; Huić, Mirjana; Sauerland, Stefan; Kuijpers, Marja R; Abrishami, Payam; Vondeling, Hindrik; Flamion, Bruno; Garattini, Silvio; Pavlovic, Mira; van Brabandt, Hans

    2012-07-01

    High-quality clinical evidence is most often lacking when novel high-risk devices enter the European market. At the same time, a randomized controlled trial (RCT) is often initiated as a requirement for obtaining market access in the US. Should coverage in Europe be postponed until RCT data are available? We studied the premarket clinical evaluation of innovative high-risk medical devices in Europe compared with the US, and with medicines, where appropriate. The literature and regulatory documents were checked. Representatives from industry, Competent Authorities, Notified Bodies, Ethics Committees, and HTA agencies were consulted. We also discuss patient safety and the transparency of information. In contrast to the US, there is no requirement in Europe to demonstrate the clinical efficacy of high-risk devices in the premarket phase. Patients in Europe can thus have earlier access to a potentially lifesaving device, but at the risk of insufficiently documented efficacy and safety. Variations in the stringency of clinical reviews, both at the level of Notified Bodies and Competent Authorities, do not guarantee patient safety. We tried to document the design of premarket trials in Europe and number of patients exposed, but failed as this information is not made public. Furthermore, the Helsinki Declaration is not followed with respect to the registration and publication of premarket trials. For innovative high-risk devices, new EU legislation should require the premarket demonstration of clinical efficacy and safety, using an RCT if possible, and a transparent clinical review, preferably centralized.

  19. International Standards for Radiation Sterilization of Medical Devices

    International Nuclear Information System (INIS)

    Miller, A.

    2007-01-01

    For a terminally sterilized medical device to be designated '' STERILE '', probability of finding the viable micro-organisms in the device shall be equal to or less than 1 x 10 -6 (EN 556-1:2001: Sterilization of medical devices - Requirements for medical devices to be designated '' STERILE '' - Part 1: Requirements for terminally sterilized medical devices). Author presents the main legal aspects of the international standards for radiation sterilization of medical devices

  20. MedMon: securing medical devices through wireless monitoring and anomaly detection.

    Science.gov (United States)

    Zhang, Meng; Raghunathan, Anand; Jha, Niraj K

    2013-12-01

    Rapid advances in personal healthcare systems based on implantable and wearable medical devices promise to greatly improve the quality of diagnosis and treatment for a range of medical conditions. However, the increasing programmability and wireless connectivity of medical devices also open up opportunities for malicious attackers. Unfortunately, implantable/wearable medical devices come with extreme size and power constraints, and unique usage models, making it infeasible to simply borrow conventional security solutions such as cryptography. We propose a general framework for securing medical devices based on wireless channel monitoring and anomaly detection. Our proposal is based on a medical security monitor (MedMon) that snoops on all the radio-frequency wireless communications to/from medical devices and uses multi-layered anomaly detection to identify potentially malicious transactions. Upon detection of a malicious transaction, MedMon takes appropriate response actions, which could range from passive (notifying the user) to active (jamming the packets so that they do not reach the medical device). A key benefit of MedMon is that it is applicable to existing medical devices that are in use by patients, with no hardware or software modifications to them. Consequently, it also leads to zero power overheads on these devices. We demonstrate the feasibility of our proposal by developing a prototype implementation for an insulin delivery system using off-the-shelf components (USRP software-defined radio). We evaluate its effectiveness under several attack scenarios. Our results show that MedMon can detect virtually all naive attacks and a large fraction of more sophisticated attacks, suggesting that it is an effective approach to enhancing the security of medical devices.

  1. [Hospital-based health technology assessment in France: how to proceed to evaluate innovative medical devices?].

    Science.gov (United States)

    Martelli, N; van den Brink, H; Denies, F; Dervaux, B; Germe, A F; Prognon, P; Pineau, J

    2014-01-01

    Innovative medical devices offer solutions to medical problems and greatly improve patients' outcomes. Like National Health Technology Assessment (HTA) agencies, hospitals face numerous requests for innovative and costly medical devices. To help local decision-makers, different approaches of hospital-based HTA (HB-HTA) have been adopted worldwide. The objective of the present paper is to explore HB-HTA models for adopting innovative medical devices in France and elsewhere. Four different models have been conceptualized: "ambassador" model, "mini-HTA" model, "HTA unit" model and "internal committee". Apparently, "HTA unit" and "internal committee" (or a mixture of both models) are the prevailing HB-HTA models in France. Nevertheless, some weaknesses of these models have been pointed out in previous works. Only few examples involving hospital pharmacists have been found abroad, except in France and in Italy. Finally, the harmonization of the assessment of innovative medical devices in France needs a better understanding of HB-HTA practices. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  2. Development of an Official Guideline for the Economic Evaluation of Drugs/Medical Devices in Japan.

    Science.gov (United States)

    Shiroiwa, Takeru; Fukuda, Takashi; Ikeda, Shunya; Takura, Tomoyuki; Moriwaki, Kensuke

    2017-03-01

    In Japan, cost-effectiveness evaluation was implemented on a trial basis from fiscal year 2016. The results will be applied to the future repricing of drugs and medical devices. On the basis of a request from the Central Social Insurance Medical Council (Chuikyo), our research team drafted the official methodological guideline for trial implementation. Here, we report the process of developing and the contents of the official guideline for cost-effectiveness evaluation. The guideline reflects discussions at the Chuikyo subcommittee (e.g., the role of quality-adjusted life-year) and incorporates our academic perspective. Team members generated research questions for each section of the guideline and discussions on these questions were carried out. A draft guideline was prepared and submitted to the Ministry of Health, Labour and Welfare (MHLW), and then to the subcommittee. The draft guideline was revised on the basis of the discussions at the subcommitte, if appropriate. Although the "public health care payer's perspective" is standard in this guideline, other perspectives can be applied as necessary depending on the objective of analysis. On the basis of the discussions at the subcommittee, quality-adjusted life-year will be used as the basic outcome. A discount rate of 2% per annum for costs and outcomes is recommended. The final guideline was officially approved by the Chuikyo general assembly in February 2016. This is the first officially approved guideline for the economic evaluation of drugs and medical devices in Japan. The guideline is expected to improve the quality and comparability of submitted cost-effectiveness data for decision making. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  3. Body Implanted Medical Device Communications

    Science.gov (United States)

    Yazdandoost, Kamya Yekeh; Kohno, Ryuji

    The medical care day by day and more and more is associated with and reliant upon concepts and advances of electronics and electromagnetics. Numerous medical devices are implanted in the body for medical use. Tissue implanted devices are of great interest for wireless medical applications due to the promising of different clinical usage to promote a patient independence. It can be used in hospitals, health care facilities and home to transmit patient measurement data, such as pulse and respiration rates to a nearby receiver, permitting greater patient mobility and increased comfort. As this service permits remote monitoring of several patients simultaneously it could also potentially decrease health care costs. Advancement in radio frequency communications and miniaturization of bioelectronics are supporting medical implant applications. A central component of wireless implanted device is an antenna and there are several issues to consider when designing an in-body antenna, including power consumption, size, frequency, biocompatibility and the unique RF transmission challenges posed by the human body. The radiation characteristics of such devices are important in terms of both safety and performance. The implanted antenna and human body as a medium for wireless communication are discussed over Medical Implant Communications Service (MICS) band in the frequency range of 402-405MHz.

  4. MEDIC: medical embedded device for individualized care.

    Science.gov (United States)

    Wu, Winston H; Bui, Alex A T; Batalin, Maxim A; Au, Lawrence K; Binney, Jonathan D; Kaiser, William J

    2008-02-01

    Presented work highlights the development and initial validation of a medical embedded device for individualized care (MEDIC), which is based on a novel software architecture, enabling sensor management and disease prediction capabilities, and commercially available microelectronic components, sensors and conventional personal digital assistant (PDA) (or a cell phone). In this paper, we present a general architecture for a wearable sensor system that can be customized to an individual patient's needs. This architecture is based on embedded artificial intelligence that permits autonomous operation, sensor management and inference, and may be applied to a general purpose wearable medical diagnostics. A prototype of the system has been developed based on a standard PDA and wireless sensor nodes equipped with commercially available Bluetooth radio components, permitting real-time streaming of high-bandwidth data from various physiological and contextual sensors. We also present the results of abnormal gait diagnosis using the complete system from our evaluation, and illustrate how the wearable system and its operation can be remotely configured and managed by either enterprise systems or medical personnel at centralized locations. By using commercially available hardware components and software architecture presented in this paper, the MEDIC system can be rapidly configured, providing medical researchers with broadband sensor data from remote patients and platform access to best adapt operation for diagnostic operation objectives.

  5. Medical Devices

    NARCIS (Netherlands)

    Verkerke, Gijsbertus Jacob; Mahieu, H.F.; Geertsema, A.A.; Hermann, I.F.; van Horn, J.R.; Hummel, J. Marjan; van Loon, J.P.; Mihaylov, D.; van der Plaats, A.; Schraffordt Koops, H.; Schutte, H.K.; Veth, R.P.H.; de Vries, M.P.; Rakhorst, G.; Shi, Donglu

    2004-01-01

    The development of new medical devices is a very time-consuming and costly process. Besides the time between the initial idea and the time that manufacturing and testing of prototypes takes place, the time needed for the development of production facilities, production of test series, marketing,

  6. Constructing the informatics and information technology foundations of a medical device evaluation system: a report from the FDA unique device identifier demonstration.

    Science.gov (United States)

    Drozda, Joseph P; Roach, James; Forsyth, Thomas; Helmering, Paul; Dummitt, Benjamin; Tcheng, James E

    2018-02-01

    The US Food and Drug Administration (FDA) has recognized the need to improve the tracking of medical device safety and performance, with implementation of Unique Device Identifiers (UDIs) in electronic health information as a key strategy. The FDA funded a demonstration by Mercy Health wherein prototype UDIs were incorporated into its electronic information systems. This report describes the demonstration's informatics architecture. Prototype UDIs for coronary stents were created and implemented across a series of information systems, resulting in UDI-associated data flow from manufacture through point of use to long-term follow-up, with barcode scanning linking clinical data with UDI-associated device attributes. A reference database containing device attributes and the UDI Research and Surveillance Database (UDIR) containing the linked clinical and device information were created, enabling longitudinal assessment of device performance. The demonstration included many stakeholders: multiple Mercy departments, manufacturers, health system partners, the FDA, professional societies, the National Cardiovascular Data Registry, and information system vendors. The resulting system of systems is described in detail, including entities, functions, linkage between the UDIR and proprietary systems using UDIs as the index key, data flow, roles and responsibilities of actors, and the UDIR data model. The demonstration provided proof of concept that UDIs can be incorporated into provider and enterprise electronic information systems and used as the index key to combine device and clinical data in a database useful for device evaluation. Keys to success and challenges to achieving this goal were identified. Fundamental informatics principles were central to accomplishing the system of systems model. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  7. Regulatory Science in Practice (Pharmaceuticals and Medical Devices Agency).

    Science.gov (United States)

    Hojo, Taisuke

    2017-01-01

    Review, safety, and relief services of the Pharmaceuticals and Medical Devices Agency are primarily focused on scientifically evaluating pharmaceuticals, medical devices, and cellular and tissue-based products referring to their quality, efficacy, and safety, which requires a variety of scientific knowledge and methods. Pharmaceutical regulation should be established based on the most advanced scientific expertise at all times. In order to evaluate products that use cutting-edge technology such as induced pluripotent stem cells and information and communication technology adequately, since fiscal year 2012 the Science Committee has been established as a platform to exchange opinions among members from top-ranking domestic and international academia and to enhance personnel exchanges through the Initiative to Facilitate Development of Innovative Drugs. In addition, the Regulatory Science Center will be established in 2018 to increase the integrity of our services for product reviews and safety measures. In particular, requiring electronic data submissions for clinical trial applications followed by an advanced approach to analysis should not only enhance the quality of reviews of individual products but should also support the development of pharmaceuticals and medical devices by providing pharmaceutical affairs consultations on research and development strategies with various guidelines based on new insights resulting from product-bridging data analysis. Moreover, a database including electronic health records with comprehensive medical information collected mainly from 10 cooperating medical institutions will be developed with the aim of developing safety measures in a more timely manner using methods of pharmacoepidemiological analysis.

  8. Electromagnetic compatibility of WLAN adapters with life-supporting medical devices.

    Science.gov (United States)

    Calcagnini, G; Mattei, E; Censi, F; Triventi, M; Lo Sterzo, R; Marchetta, E; Bartolini, P

    2011-05-01

    This paper investigates the electromagnetic compatibility of 45 critical care medical devices (infusion pumps, defibrillators, monitors, lung ventilators, anesthesia machines and external pacemakers) with various types of wireless local area network (WLAN, IEEE 802.11 b/g, 2.45 GHz, 100 mW) adapters. Interference is evaluated by performing ad-hoc tests according to the ANSI C63.18 recommended practice. The behavior of the devices during the tests was monitored using patient simulators/device testers specific for each device class. Electromagnetic interference cases were observed in three of 45 devices at a maximum distance of 5 cm. In two cases the interference caused malfunctions that may have clinical consequences for the patient. The authors' findings show that the use of these wireless local area network adapters can be considered reasonably safe, although interference may occur if they are operated at very close distance (<10 cm) to the medical devices.

  9. An extended protocol for usability validation of medical devices : Research design and reference model

    NARCIS (Netherlands)

    Schmettow, M.; Schnittker, R.; Schraagen, J.M.

    2017-01-01

    This paper proposes and demonstrates an extended protocol for usability validation testing of medical devices. A review of currently used methods for the usability evaluation of medical devices revealed two main shortcomings. Firstly, the lack of methods to closely trace the interaction sequences

  10. [Impact of an automated dispensing system for medical devices in cardiac surgery department].

    Science.gov (United States)

    Clou, E; Dompnier, M; Kably, B; Leplay, C; Poupon, E; Archer, V; Paul, M

    2018-01-01

    To secure medical devices' management, the implementation of automated dispensing system in surgical service has been realized. The objective of this study was to evaluate security, organizational and economic impact of installing automated dispensing system for medical devices (ASDM). The implementation took place in a cardiac surgery department. Security impact was assessed by comparing traceability rate of implantable medical devices one year before and one year after installation. Questionnaire on nurses' perception and satisfaction completed this survey. Resupplying costs, stocks' evolution and investments for the implementation of ASDM were the subject of cost-benefit study. After one year, traceability rate is excellent (100%). Nursing staffs were satisfied with 87.5% by this new system. The introduction of ASDM allowed a qualitative and quantitative decrease in stocks, with a reduction of 30% for purchased medical devices and 15% for implantable medical devices in deposit-consignment. Cost-benefit analysis shows a rapid return on investment. Real stock decrease (purchased medical devices) is equivalent to 46.6% of investment. Implementation of ASDM allows to secure storage and dispensing of medical devices. This system has also an important economic impact and appreciated by users. Copyright © 2017 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.

  11. Legislative aspects of the development of medical devices.

    Science.gov (United States)

    Marešová, Petra; Klímová, Blanka; Krejcar, Ondřej; Kuča, Kamil

    2015-09-01

    European industry of medical device technologies represents 30% of all worlds sales. New health technologies bring effective treatment approaches, help shorten stays in hospital1),bring better treatment results and accelerate rehabilitation which leads to the earlier patients recovery.Legislative aspects are one of the key areas influencing the speed of development of medical devices and their launching. The aim of this article is to specify current state of legislation in the development of medical devices in the European Union in comparison with the market leaders such as China, Japan and USA.The best established market of medical devices is in the USA. Both Japan and China follow the USA model. However, a non-professional code of ethics in China in some respect contributes to the decrease of quality of medical devices, while Japan as well as the EU countries try really hard to conform to all the regulations imposed on the manufacturing of medical devices.

  12. Mobile medical device connectivity: real world solutions.

    Science.gov (United States)

    Pettus, Dan

    2004-01-01

    Mobile medical devices, such as infusion pumps, provide an important therapeutic function. They are also valuable sources of information about treatment patterns at the point of care. However, these mobile devices have been independent islands of valuable information, unable to share the data they gather with other hospital information resources on a real time basis. Although data from these devices can provide significant improvements for medical safety and vital information needed for clinical best practice development, gathering that data poses significant challenges when interfacing with hospital information systems. Mobile medical devices move from place to place as independent actors, raising a series of security and identification issues when they need to be disconnected and reconnected using traditional tethered cable connections. The continuing lack of accepted communications protocol standards, in spite of the concentrated efforts of organizations like the IEEE and the Medical Information Bus (IEEE 1073) to establish them, has made integration into the hospital information system a complex and non-standard task. The rapid spread in availability and adoption of high-speed 802.11 wireless systems in hospitals offers a realistic connectivity solution for mobile medical devices. Inspite of this, the 802.11 standard is still evolving, and current security methods designed for user-based products like PDAs and laptop computers are not ideal for unmanned mobile medical devices because they assume the availability of a human operator to authenticate a wireless session. In the absence of accepted standards, manufacturers have created practical and innovative solutions to support the collection of clinical data from mobile medical devices and the integration of that data with hospital information systems. This paper will explore the potential benefits of integrating mobile medical devices into the hospital information system, and describe the challenges in

  13. An Initial Evaluation of Tablet Devices & What Are the Next Steps?

    Science.gov (United States)

    McKillen, Tracey

    2016-01-01

    This paper describes an evaluation of tablet devices for a Graduate Entry Medical School (GEMS). The purpose of this evaluation is to assess what type of tablet device could meet the needs of a GEMS student. GEMS requirements for the evaluation include; using the tablet device to replace paper teaching resources in lectures and tutorials and…

  14. Analytical Chemistry in the Regulatory Science of Medical Devices.

    Science.gov (United States)

    Wang, Yi; Guan, Allan; Wickramasekara, Samanthi; Phillips, K Scott

    2018-06-12

    In the United States, regulatory science is the science of developing new tools, standards, and approaches to assess the safety, efficacy, quality, and performance of all Food and Drug Administration-regulated products. Good regulatory science facilitates consumer access to innovative medical devices that are safe and effective throughout the Total Product Life Cycle (TPLC). Because the need to measure things is fundamental to the regulatory science of medical devices, analytical chemistry plays an important role, contributing to medical device technology in two ways: It can be an integral part of an innovative medical device (e.g., diagnostic devices), and it can be used to support medical device development throughout the TPLC. In this review, we focus on analytical chemistry as a tool for the regulatory science of medical devices. We highlight recent progress in companion diagnostics, medical devices on chips for preclinical testing, mass spectrometry for postmarket monitoring, and detection/characterization of bacterial biofilm to prevent infections.

  15. Pricing and reimbursement of drugs and medical devices in Hungary.

    Science.gov (United States)

    Gulácsi, L; Dávid, T; Dózsa, Cs

    2002-01-01

    Similarly to other countries of Central and Eastern Europe, Hungary has witnessed massive diffusion of healthcare technology such as drugs and medical devices since 1990. While substantial new pharmaceuticals, medical devices, and procedures have been liberalized, there has been no proper evaluation or training in their use. Healthcare providers have come to find themselves as entrepreneurs in private practice, while patients are acquiring an increasing awareness as customers of healthcare,demanding services in return for their taxes and contributions. This has led to extremely irrational patterns of investment in technology, with most an obvious waste of resources, while leaving basic needs unmet. Both the National Health Insurance Fund and the Ministry of Finance believe that the current pharmaceutical and medical device bill is too high. However, introducing a more transparent and flexible pricing and reimbursement framework may enable a more efficient allocation of the limited resources to be achieved.

  16. An update on mobile phones interference with medical devices.

    Science.gov (United States)

    Mahmoud Pashazadeh, Ali; Aghajani, Mahdi; Nabipour, Iraj; Assadi, Majid

    2013-10-01

    Mobile phones' electromagnetic interference with medical devices is an important issue for the medical safety of patients who are using life-supporting medical devices. This review mainly focuses on mobile phones' interference with implanted medical devices and with medical equipment located in critical areas of hospitals. A close look at the findings reveals that mobile phones may adversely affect the functioning of medical devices, and the specific effect and the degree of interference depend on the applied technology and the separation distance. According to the studies' findings and the authors' recommendations, besides mitigating interference, using mobile phones at a reasonable distance from medical devices and developing technology standards can lead to their effective use in hospital communication systems.

  17. An update on mobile phones interference with medical devices

    International Nuclear Information System (INIS)

    Pashazadeh, A. M.; Aghajani, M.; Nabipour, I.; Assadi, M.

    2013-01-01

    Mobile phones' electromagnetic interference with medical devices is an important issue for the medical safety of patients who are using life-supporting medical devices. This review mainly focuses on mobile phones' interference with implanted medical devices and with medical equipment located in critical areas of hospitals. A close look at the findings reveals that mobile phones may adversely affect the functioning of medical devices, and the specific effect and the degree of interference depend on the applied technology and the separation distance. According to the studies' findings and the authors' recommendations, besides mitigating interference, using mobile phones at a reasonable distance from medical devices and developing technology standards can lead to their effective use in hospital communication systems. (authors)

  18. Medical devices and human engineering

    CERN Document Server

    Bronzino, Joseph D

    2014-01-01

    Known as the bible of biomedical engineering, The Biomedical Engineering Handbook, Fourth Edition, sets the standard against which all other references of this nature are measured. As such, it has served as a major resource for both skilled professionals and novices to biomedical engineering.Medical Devices and Human Engineering, the second volume of the handbook, presents material from respected scientists with diverse backgrounds in biomedical sensors, medical instrumentation and devices, human performance engineering, rehabilitation engineering, and clinical engineering.More than three doze

  19. Medical device reliability and associated areas

    National Research Council Canada - National Science Library

    Dhillon, Balbir S

    2000-01-01

    .... Although the history of reliability engineering can be traced back to World War II, the application of reliability engineering concepts to medical devices is a fairly recent idea that goes back to the latter part of the 1960s when many publications on medical device reliability emerged. Today, a large number of books on general reliability have been...

  20. Model-based engineering for medical-device software.

    Science.gov (United States)

    Ray, Arnab; Jetley, Raoul; Jones, Paul L; Zhang, Yi

    2010-01-01

    This paper demonstrates the benefits of adopting model-based design techniques for engineering medical device software. By using a patient-controlled analgesic (PCA) infusion pump as a candidate medical device, the authors show how using models to capture design information allows for i) fast and efficient construction of executable device prototypes ii) creation of a standard, reusable baseline software architecture for a particular device family, iii) formal verification of the design against safety requirements, and iv) creation of a safety framework that reduces verification costs for future versions of the device software. 1.

  1. A concept ideation framework for medical device design.

    Science.gov (United States)

    Hagedorn, Thomas J; Grosse, Ian R; Krishnamurty, Sundar

    2015-06-01

    Medical device design is a challenging process, often requiring collaboration between medical and engineering domain experts. This collaboration can be best institutionalized through systematic knowledge transfer between the two domains coupled with effective knowledge management throughout the design innovation process. Toward this goal, we present the development of a semantic framework for medical device design that unifies a large medical ontology with detailed engineering functional models along with the repository of design innovation information contained in the US Patent Database. As part of our development, existing medical, engineering, and patent document ontologies were modified and interlinked to create a comprehensive medical device innovation and design tool with appropriate properties and semantic relations to facilitate knowledge capture, enrich existing knowledge, and enable effective knowledge reuse for different scenarios. The result is a Concept Ideation Framework for Medical Device Design (CIFMeDD). Key features of the resulting framework include function-based searching and automated inter-domain reasoning to uniquely enable identification of functionally similar procedures, tools, and inventions from multiple domains based on simple semantic searches. The significance and usefulness of the resulting framework for aiding in conceptual design and innovation in the medical realm are explored via two case studies examining medical device design problems. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Power Approaches for Implantable Medical Devices

    Directory of Open Access Journals (Sweden)

    Achraf Ben Amar

    2015-11-01

    Full Text Available Implantable medical devices have been implemented to provide treatment and to assess in vivo physiological information in humans as well as animal models for medical diagnosis and prognosis, therapeutic applications and biological science studies. The advances of micro/nanotechnology dovetailed with novel biomaterials have further enhanced biocompatibility, sensitivity, longevity and reliability in newly-emerged low-cost and compact devices. Close-loop systems with both sensing and treatment functions have also been developed to provide point-of-care and personalized medicine. Nevertheless, one of the remaining challenges is whether power can be supplied sufficiently and continuously for the operation of the entire system. This issue is becoming more and more critical to the increasing need of power for wireless communication in implanted devices towards the future healthcare infrastructure, namely mobile health (m-Health. In this review paper, methodologies to transfer and harvest energy in implantable medical devices are introduced and discussed to highlight the uses and significances of various potential power sources.

  3. Evaluation of commercial self-monitoring devices for clinical purposes

    DEFF Research Database (Denmark)

    Leth, Søren; Hansen, John; Nielsen, Olav Wendelboe

    2017-01-01

    Commercial self-monitoring devices are becoming increasingly popular, and over the last decade, the use of self-monitoring technology has spread widely in both consumer and medical markets. The purpose of this study was to evaluate five commercially available self-monitoring devices for further...

  4. [Software as medical devices/medical apps : Tasks, requirements, and experiences from the point of view of a competent authority].

    Science.gov (United States)

    Terhechte, Arno

    2018-03-01

    Software can be classified as a medical device according to the Medical Device Directive 93/42/EEC. The number of software products and medical apps is continuously increasing and so too is the use in health institutions (e. g., in hospitals and doctors' surgeries) for diagnosis and therapy.Different aspects of standalone software and medical apps from the perspective of the authority responsible are presented. The quality system implemented to establish a risk-based systematic inspection and supervision of manufacturers is discussed. The legal framework, as well as additional standards that are the basis for inspection, are outlined. The article highlights special aspects that occur during inspection like verification of software and interfaces, and the clinical evaluation of software. The Bezirksregierung, as the local government authority responsible in North Rhine-Westphalia, is also in charge of inspection of health institutions. Therefore this article is not limited to the manufacturers placing the software on the market, but in addition it describes the management and use of software as a medical device in hospitals.The future legal framework, the Medical Device Regulation, will strengthen the requirements and engage notified bodies more than today in the conformity assessment of software as a medical device.Manufacturers, health institutions, notified bodies and the authorities responsible are in charge of intensifying their efforts towards software as a medical device. Mutual information, improvement of skills, and inspections will lead to compliance with regulatory requirements.

  5. Towards sustainable design for single-use medical devices.

    Science.gov (United States)

    Hanson, Jacob J; Hitchcock, Robert W

    2009-01-01

    Despite their sophistication and value, single-use medical devices have become commodity items in the developed world. Cheap raw materials along with large scale manufacturing and distribution processes have combined to make many medical devices more expensive to resterilize, package and restock than to simply discard. This practice is not sustainable or scalable on a global basis. As the petrochemicals that provide raw materials become more expensive and the global reach of these devices continues into rapidly developing economies, there is a need for device designs that take into account the total life-cycle of these products, minimize the amount of non-renewable materials consumed and consider alternative hybrid reusable / disposable approaches. In this paper, we describe a methodology to perform life cycle and functional analyses to create additional design requirements for medical devices. These types of sustainable approaches can move the medical device industry even closer to the "triple bottom line"--people, planet, profit.

  6. 78 FR 21129 - Orthopaedic and Rehabilitation Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2013-04-09

    ... radiofrequency band ranging between 13 megahertz to 27.12 megahertz and is intended for the treatment of medical...] Orthopaedic and Rehabilitation Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: Orthopaedic and Rehabilitation Devices Panel of the Medical Devices...

  7. Anti-malware software and medical devices.

    Science.gov (United States)

    2010-10-01

    Just as much as healthcare information systems, medical devices need protection against cybersecurity threats. Anti-malware software can help safeguard the devices in your facility-but it has limitations and even risks. Find out what steps you can take to manage anti-malware applications in your devices.

  8. MDR (Medical Device Reporting)

    Data.gov (United States)

    U.S. Department of Health & Human Services — This database allows you to search the CDRH's database information on medical devices which may have malfunctioned or caused a death or serious injury during the...

  9. 78 FR 68714 - Medical Devices; Ophthalmic Devices; Classification of the Scleral Plug

    Science.gov (United States)

    2013-11-15

    ... amendments), as ``preamendments devices.'' FDA classifies these devices after the Agency takes the following.... FDA-2012-N-1238] Medical Devices; Ophthalmic Devices; Classification of the Scleral Plug AGENCY: Food... scleral plugs in order to provide a reasonable assurance of safety and effectiveness of the device. The...

  10. Use of mobile devices for medical imaging.

    Science.gov (United States)

    Hirschorn, David S; Choudhri, Asim F; Shih, George; Kim, Woojin

    2014-12-01

    Mobile devices have fundamentally changed personal computing, with many people forgoing the desktop and even laptop computer altogether in favor of a smaller, lighter, and cheaper device with a touch screen. Doctors and patients are beginning to expect medical images to be available on these devices for consultative viewing, if not actual diagnosis. However, this raises serious concerns with regard to the ability of existing mobile devices and networks to quickly and securely move these images. Medical images often come in large sets, which can bog down a network if not conveyed in an intelligent manner, and downloaded data on a mobile device are highly vulnerable to a breach of patient confidentiality should that device become lost or stolen. Some degree of regulation is needed to ensure that the software used to view these images allows all relevant medical information to be visible and manipulated in a clinically acceptable manner. There also needs to be a quality control mechanism to ensure that a device's display accurately conveys the image content without loss of contrast detail. Furthermore, not all mobile displays are appropriate for all types of images. The smaller displays of smart phones, for example, are not well suited for viewing entire chest radiographs, no matter how small and numerous the pixels of the display may be. All of these factors should be taken into account when deciding where, when, and how to use mobile devices for the display of medical images. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  11. 77 FR 72924 - Taxable Medical Devices

    Science.gov (United States)

    2012-12-07

    ... in hospitals, doctors offices and other medical institutions, such as x-ray machines, magnetic... the medical device context include sales to hospitals and other medical service providers. Although... of a taxable article to charity constitutes a taxable use under section 4218. However, the IRS and...

  12. Development of Implantable Medical Devices: From an Engineering Perspective

    Directory of Open Access Journals (Sweden)

    Yeun-Ho Joung

    2013-09-01

    Full Text Available From the first pacemaker implant in 1958, numerous engineering and medical activities for implantable medical device development have faced challenges in materials, battery power, functionality, electrical power consumption, size shrinkage, system delivery, and wireless communication. With explosive advances in scientific and engineering technology, many implantable medical devices such as the pacemaker, cochlear implant, and real-time blood pressure sensors have been developed and improved. This trend of progress in medical devices will continue because of the coming super-aged society, which will result in more consumers for the devices. The inner body is a special space filled with electrical, chemical, mechanical, and marine-salted reactions. Therefore, electrical connectivity and communication, corrosion, robustness, and hermeticity are key factors to be considered during the development stage. The main participants in the development stage are the user, the medical staff, and the engineer or technician. Thus, there are three different viewpoints in the development of implantable devices. In this review paper, considerations in the development of implantable medical devices will be presented from the viewpoint of an engineering mind.

  13. Preventing medical device recalls

    CERN Document Server

    Raheja, Dev

    2014-01-01

    Introduction to Medical Device RequirementsIntroductionThe ChallengesSources of ErrorsUnderstanding the Science of Safety     Overview of FDA Quality System Regulation     Overview of Risk Management Standard ISO 14971     Overview of FDA Device Approval Process     Overview of Regulatory Requirements for Clinical TrialsSummaryReferencesPreventing Recalls during Specification WritingIntroductionConduct Requirements Analysis to Identify Missing RequirementsSpecifications for Safety, Durability, and

  14. 78 FR 26786 - Microbiology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2013-05-08

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-0001] Microbiology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and Drug...: Microbiology Devices Panel of the Medical Devices Advisory Committee. General Function of the Committee: To...

  15. 76 FR 48871 - Immunology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2011-08-09

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] Immunology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and Drug...: Immunology Devices Panel of the Medical Devices Advisory Committee. General Function of the Committee: To...

  16. Product-based Safety Certification for Medical Devices Embedded Software.

    Science.gov (United States)

    Neto, José Augusto; Figueiredo Damásio, Jemerson; Monthaler, Paul; Morais, Misael

    2015-01-01

    Worldwide medical device embedded software certification practices are currently focused on manufacturing best practices. In Brazil, the national regulatory agency does not hold a local certification process for software-intensive medical devices and admits international certification (e.g. FDA and CE) from local and international industry to operate in the Brazilian health care market. We present here a product-based certification process as a candidate process to support the Brazilian regulatory agency ANVISA in medical device software regulation. Center of Strategic Technology for Healthcare (NUTES) medical device embedded software certification is based on a solid safety quality model and has been tested with reasonable success against the Class I risk device Generic Infusion Pump (GIP).

  17. Managing medical equipment used by technology-dependent children: evaluation of an instructional tool for pediatric residents and medical students.

    Science.gov (United States)

    Jackson, Jennifer M; Radulovic, Andrea; Nageswaran, Savithri

    2012-08-01

    To evaluate the effectiveness of a workshop on managing medical devices used in technology-dependent children. Study participants included residents and medical students rotating in the pediatrics department at the time of the study. A workshop was conducted consisting of learning stations for common medical devices, including brief presentations and opportunities for hands-on practice with each device. Participants completed surveys before and after the workshop assessing their perceived ability to manage medical equipment before and after the workshop and their ongoing learning needs. All participants indicated a substantial need for training on how to manage medical devices used by technology-dependent patients. Scores for perceived ability to manage the devices improved significantly after workshop participation for nearly all devices taught. Medical trainees have significant learning needs for managing devices used by technology-dependent patients. Hands-on, small-group training can be an effective instructional tool for improving confidence in these skills.

  18. On the impact of medical device regulations on software architecture

    DEFF Research Database (Denmark)

    Hansen, Klaus Marius; Manikas, Konstantinos

    2016-01-01

    Compliance to regulations and regulatory approval are requirements for many medical device software systems. In this paper, we investigate the implications of medical device software regulations to the design of software systems. We do so by focusing on the American and European regulatory author...... of the device. Moreover, we review software modularity in the implementation of software medical device and propose a set of preliminary principles for architectural design of software medical device based on a set of constrains identified from the reviewed regulations....

  19. On-line integration of computer controlled diagnostic devices and medical information systems in undergraduate medical physics education for physicians.

    Science.gov (United States)

    Hanus, Josef; Nosek, Tomas; Zahora, Jiri; Bezrouk, Ales; Masin, Vladimir

    2013-01-01

    We designed and evaluated an innovative computer-aided-learning environment based on the on-line integration of computer controlled medical diagnostic devices and a medical information system for use in the preclinical medical physics education of medical students. Our learning system simulates the actual clinical environment in a hospital or primary care unit. It uses a commercial medical information system for on-line storage and processing of clinical type data acquired during physics laboratory classes. Every student adopts two roles, the role of 'patient' and the role of 'physician'. As a 'physician' the student operates the medical devices to clinically assess 'patient' colleagues and records all results in an electronic 'patient' record. We also introduced an innovative approach to the use of supportive education materials, based on the methods of adaptive e-learning. A survey of student feedback is included and statistically evaluated. The results from the student feedback confirm the positive response of the latter to this novel implementation of medical physics and informatics in preclinical education. This approach not only significantly improves learning of medical physics and informatics skills but has the added advantage that it facilitates students' transition from preclinical to clinical subjects. Copyright © 2011 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  20. 76 FR 7220 - Medical Device Innovation Initiative; Request for Comments

    Science.gov (United States)

    2011-02-09

    ... medical device innovation. 6. Other actions CDRH should take to facilitate the development, assessment...] Medical Device Innovation Initiative; Request for Comments AGENCY: Food and Drug Administration, HHS... availability of a document for public comment entitled ``Medical Device Innovation Initiative'' (the report...

  1. 78 FR 68853 - International Medical Device Regulators Forum; Medical Device Single Audit Program International...

    Science.gov (United States)

    2013-11-15

    ... its inaugural meeting in Singapore in 2012, identified a Work Group (WG) to develop specific documents... Assessment Method for the Recognition and Monitoring of Medical Device Auditing Organizations;'' and IMDRF...

  2. A model of user engagement in medical device development.

    Science.gov (United States)

    Grocott, Patricia; Weir, Heather; Ram, Mala Bridgelal

    2007-01-01

    The purpose of this paper is to address three topical themes: user involvement in health services research; determining the value of new medical technologies in patient care pathways, furthering knowledge related to quality in health and social care; and knowledge exchange between manufacturers, health service supply chain networks and device users. The model is being validated in a case study in progress. The latter is a "proving ground" study for a translational research company. Medical devices play a pivotal role in the management of chronic diseases, across all care settings. Failure to engage users in device development inevitably affects the quality of clinical outcomes. A model of user engagement is presented, turning unmet needs for medical devices into viable commercial propositions. A case study investigating the perceptions of individuals with Epidermolysis Bullosa (EB), their lay and professional carers into unmet needs. EB is an inherited condition affecting the skin and mucosal linings that leads to blistering and wounds. Qualitative data are being collected to generate understanding of unmet needs and wound care products. These needs are being translated into new design concepts and prototypes. Prototypes will be evaluated in an n = 1 experimental design, generating quantitative outcomes data. There are generalisations from the case study, and the model outlined. New products for managing EB wounds can logically benefit other groups. The model is transferable to other clinical problems, which can benefit from research and technological advances that are integral to clinical needs and care.

  3. The "déjà vu effect:" evaluation of United States medical device legislation, regulation, and the Food and Drug Administration's contentious 510(k) program.

    Science.gov (United States)

    Bauman, Jordan

    2012-01-01

    With the Medical Device Amendments of 1976, Congress granted FDA authority to regulate medical devices by implementing a risk-based regulatory framework. Several years prior to this legislation, the Cooper Committee reviewed the medical device regulatory landscape and uncovered weaknesses that could be detrimental to public health. However, only after several high-profile incidents involving unsafe medical devices did Congress respond with strong legislation. Since 1976, additional medical device legislative revisions have been enacted to address deficiencies highlighted by various groups representing Congress, FDA, and industry. A repetitive conclusion from these groups has been that the 510(k) program is incapable of serving as a premarket evaluation of safety and effectiveness under the existing statutory framework. However, these legislative revisions did not change the statutory framework despite these repeated findings. In 2009, CDRH convened separate groups to again review the 510(k) program. While more comprehensive than previous initiatives, the observed deficiencies and the proposed recommendations are remarkably similar to those identified by their predecessors. This cyclical review of the medical device regulatory landscape whereby the same observations and recommendations are repeated yet the output of such review does not yield major legislative revision of the existing statutory framework can be described as the "déjà vu effect." This will continue unless Congress enacts legislation that implements a new statutory framework with a different standard other than substantial equivalence. In the past, Congress has implemented major legislation only after a public health crisis. Hopefully this will not be the driving force in the future.

  4. Wireless energy transfer platform for medical sensors and implantable devices.

    Science.gov (United States)

    Zhang, Fei; Hackworth, Steven A; Liu, Xiaoyu; Chen, Haiyan; Sclabassi, Robert J; Sun, Mingui

    2009-01-01

    Witricity is a newly developed technique for wireless energy transfer. This paper presents a frequency adjustable witricity system to power medical sensors and implantable devices. New witricity resonators are designed for both energy transmission and reception. A prototype platform is described, including an RF power source, two resonators with new structures, and inductively coupled input and output stages. In vitro experiments, both in open air and using a human head phantom consisting of simulated tissues, are employed to verify the feasibility of this platform. An animal model is utilized to evaluate in vivo energy transfer within the body of a laboratory pig. Our experiments indicate that witricity is an effective new tool for providing a variety of medical sensors and devices with power.

  5. The current situation and development of medical device testing institutes in China.

    Science.gov (United States)

    Yang, Xiaofang; Mu, Ruihong; Fan, Yubo; Wang, Chunren; Li, Deyu

    2017-04-01

    This article analyses the current situation and development of Chinese medical device testing institutes from the perspectives of the two most important functions - testing functions and medical device standardization functions. Areas Covered: The objective of the Chinese government regulations for medical device industry is to ensure the safety and effectiveness of medical devices for Chinese patients. To support the regulation system, the Chinese government has established medical device testing institutes at different levels for example, the national, provincial, and municipal levels. These testing institutes also play an important role in technical support during medical device premarket registration and post market surveillance, they are also the vital practitioners of Chinese medical device standardization. Expert Commentary: Chinese medical device testing institutes are technical departments established by government, and serve the regulatory functions of government agency. In recent years, with the rapid development of medical device industry as well as constantly increasing international and domestic medical device market, the importance of medical device testing institute is more prominent, However, there are still some problems unsolved, such as their overall capacity remains to be improved, construction of standardization is to be strengthened, etc.

  6. Medical devices for the anesthetist: current perspectives

    Directory of Open Access Journals (Sweden)

    Ingrande J

    2014-03-01

    Full Text Available Jerry Ingrande, Hendrikus JM LemmensDepartment of Anesthesiology, Perioperative and Pain Medicine, Stanford University School of Medicine, Stanford, CA, USAAbstract: Anesthesiologists are unique among most physicians in that they routinely use technology and medical devices to carry out their daily activities. Recently, there have been significant advances in medical technology. These advances have increased the number and utility of medical devices available to the anesthesiologist. There is little doubt that these new tools have improved the practice of anesthesia. Monitoring has become more comprehensive and less invasive, airway management has become easier, and placement of central venous catheters and regional nerve blockade has become faster and safer. This review focuses on key medical devices such as cardiovascular monitors, airway equipment, neuromonitoring tools, ultrasound, and target controlled drug delivery software and hardware. This review demonstrates how advances in these areas have improved the safety and efficacy of anesthesia and facilitate its administration. When applicable, indications and contraindications to the use of these novel devices will be explored as well as the controversies surrounding their use.Keywords: catheters, echocardiography, ultrasound, fiberoptic bronchoscope, laryngeal mask airway, closed-loop anesthesia

  7. 77 FR 18829 - Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2012-03-28

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-N-0001] Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY... public. Name of Committee: Gastroenterology and Urology Devices Panel of the Medical Devices Advisory...

  8. 76 FR 71983 - Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-11-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY... public. Name of Committee: Gastroenterology and Urology Devices Panel of the Medical Devices Advisory...

  9. 42 CFR 410.36 - Medical supplies, appliances, and devices: Scope.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Medical supplies, appliances, and devices: Scope... Services § 410.36 Medical supplies, appliances, and devices: Scope. (a) Medicare Part B pays for the following medical supplies, appliances and devices: (1) Surgical dressings, and splints, casts, and other...

  10. 75 FR 57968 - Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2010-09-23

    ...] Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY... public. Name of Committee: Gastroenterology and Urology Devices Panel of the Medical Devices Advisory... committee will discuss, make recommendations, and vote on information related to the PMA for the LAP-BAND...

  11. 76 FR 55398 - Immunology Devices Panel of the Medical Devices Advisory Committee: Notice of Postponement of...

    Science.gov (United States)

    2011-09-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] Immunology Devices Panel of the Medical Devices Advisory Committee: Notice of Postponement of Meeting AGENCY... postponing the meeting of the Immunology Devices Panel of the Medical Devices Advisory Committee scheduled...

  12. A Medical Delivery Device

    DEFF Research Database (Denmark)

    2010-01-01

    The present invention relates to a medical delivery device comprising at least two membrane electrode assembly units each of which comprises three layers: an upper and a lower electrode and a selective ionic conductive membrane provided there-between. At least one of the three layers are shared...

  13. Medical Device Integration Model Based on the Internet of Things

    Science.gov (United States)

    Hao, Aiyu; Wang, Ling

    2015-01-01

    At present, hospitals in our country have basically established the HIS system, which manages registration, treatment, and charge, among many others, of patients. During treatment, patients need to use medical devices repeatedly to acquire all sorts of inspection data. Currently, the output data of the medical devices are often manually input into information system, which is easy to get wrong or easy to cause mismatches between inspection reports and patients. For some small hospitals of which information construction is still relatively weak, the information generated by the devices is still presented in the form of paper reports. When doctors or patients want to have access to the data at a given time again, they can only look at the paper files. Data integration between medical devices has long been a difficult problem for the medical information system, because the data from medical devices are lack of mandatory unified global standards and have outstanding heterogeneity of devices. In order to protect their own interests, manufacturers use special protocols, etc., thus causing medical decices to still be the "lonely island" of hospital information system. Besides, unfocused application of the data will lead to failure to achieve a reasonable distribution of medical resources. With the deepening of IT construction in hospitals, medical information systems will be bound to develop towards mobile applications, intelligent analysis, and interconnection and interworking, on the premise that there is an effective medical device integration (MDI) technology. To this end, this paper presents a MDI model based on the Internet of Things (IoT). Through abstract classification, this model is able to extract the common characteristics of the devices, resolve the heterogeneous differences between them, and employ a unified protocol to integrate data between devices. And by the IoT technology, it realizes interconnection network of devices and conducts associate matching

  14. Handbook of materials for medical devices

    National Research Council Canada - National Science Library

    Davis, J. R

    2003-01-01

    ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Introduction Chapter 1 Overview of Biomaterials and Their Use in Medical Devices . . . . . . . . . . . . . . . . 1 Uses for Biomaterials...

  15. Cybersecurity and the Medical Device Product Development Lifecycle.

    Science.gov (United States)

    Jones, Richard W; Katzis, Konstantinos

    2017-01-01

    Protecting connected medical devices from evolving cyber related threats, requires a continuous lifecycle approach whereby cybersecurity is integrated within the product development lifecycle and both complements and re-enforces the safety risk management processes therein. This contribution reviews the guidance relating to medical device cybersecurity within the product development lifecycle.

  16. BIOANALYTICAL STANDARDIZING FOR SEROLOGICAL DIAGNOSTIC MEDICAL DEVICES

    OpenAIRE

    A. Yu. Galkin; A. G. Komar; A. A. Grigorenko

    2015-01-01

    In article we analyzed national and international regulations concerning the quality and safety of medical devices for in vitro diagnostics. We discussed the possibility of a partial application of the recommendations of the State Pharmacopoeia of Ukraine to this type of product. The main guiding regulatory documents establishing requirements for quality and safety tools for the serological diagnosis products are The technical regulation on medical devices for the diagnosis in vitro, DSTU ISO...

  17. 75 FR 61507 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of...

    Science.gov (United States)

    2010-10-05

    ...] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of Notice... announcing an amendment to the notice of meeting of the General and Plastic Surgery Devices Panel of the..., FDA announced that a meeting of the General and Plastic Surgery Devices Panel of the Medical Devices...

  18. Medical device risk management and its economic impact

    Directory of Open Access Journals (Sweden)

    Katerina Krsteva Jakimovska

    2013-10-01

    Full Text Available The importance of medical devices in everyday users/patients lives is imensse. This is the reason why emphasis must be put on safety during their use. Satisfactory safety level can be achived by implementation of quality and risk management standards. Medical device manufacturers must learn to deal with the potential risks by using theoretical and practical examples and measures in order to protect their users/patients and themselves from suffering huge losses arising from adverse events or recall of their products. The best moment for implementation of risk management methods and analysis begins from the device design and development through manufacturing, sales and distribution. These way medical device manufacturers will succseed in protecting their users/patients from serious adverse events and at the same time protect their brand and society status, while minimizing economic losses.

  19. Regulation E 69-14. Monitoring requirements for medical devices

    International Nuclear Information System (INIS)

    2015-01-01

    In the 'Regulations for the State Evaluation and Registration of Medical Equipment' force (Hereinafter Rules) set forth in Chapter VII, Articles 79 and 86, the monitoring activity as one of the programs necessary for evaluating the safety and effectiveness of medical monitoring equipment. In the years 2008 and 2011 were approved and implemented by the Center for State Control of Medical Equipment (CCEEM) Regulations and -1.1 ER and ER-1 that support and regulatory requirements 'Control and monitoring of pacemakers and implantable defibrillators' and 'Assessment, recording and control after market surgical silicone implants,' which are specific to these products and have provided a useful result for the performance of the activity. Given the number and diversity of high-risk medical devices as implantable or sustain human life that are brought into our National Health System (SNS), a regulation establishing control over the behavior becomes necessary safety and effectiveness of this equipment during use, which provide inputs to risk management. The objective of this regulation is to establish the regulatory requirements for tracking medical equipment introduced in the NHS. The provisions of this Regulation is aimed at health institutions, to CECMED as manufacturers, suppliers, distributors and importers of medical equipment.

  20. 75 FR 47606 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2010-08-06

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of... General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee scheduled for August...

  1. [Design and application of implantable medical device information management system].

    Science.gov (United States)

    Cao, Shaoping; Yin, Chunguang; Zhao, Zhenying

    2013-03-01

    Through the establishment of implantable medical device information management system, with the aid of the regional joint sharing of resources, we further enhance the implantable medical device traceability management level, strengthen quality management, control of medical risk.

  2. Challenges in the Assessment of Medical Devices: The MedtecHTA Project.

    Science.gov (United States)

    Tarricone, Rosanna; Torbica, Aleksandra; Drummond, Michael

    2017-02-01

    Assessing medical devices (MDs) raises challenges which require us to reflect on whether current methods are adequate. Major features of devices are: (i) device-operator interaction can generate learning curve effects; (ii) incremental nature of innovation needs to be addressed by careful identification of the alternatives for comparative and incremental cost-effectiveness analysis; and (iii) broader organizational impact in terms of training and infrastructure, coupled with dynamic pricing, requires a more flexible approach to costing. The objective of the MedtecHTA project was to investigate improvements in HTA methods to allow for more comprehensive evaluation of MDs. It consisted of several work packages concerning (i) the available evidence on the currently adopted approaches for regulation and HTA of medical devices; (ii) the geographical variation in access to MDs; (iii) the development of methodological frameworks for conducting comparative effectiveness research and economic evaluation of MDs; and (iv) the organizational impact of MDs. This introductory paper summarizes the main results of the project and draws out the main overarching themes. This supplement represents a comprehensive report of all the main findings of the MedtecHTA project, and it is intended to be the main source for researchers and policy makers wanting information on the project. © 2017 The Authors. Health Economics published by John Wiley & Sons, Ltd. © 2017 The Authors. Health Economics Published by John Wiley & Sons, Ltd.

  3. Distribution of microorganisms in medical devices and their inactivation effects by gamma-irradiation

    International Nuclear Information System (INIS)

    Ito, Hitoshi; Ishigaki, Isao

    1986-01-01

    Radiation treatment is getting important position for sterilizing medical devices and for packaging films of foods. Recently, survey of bioburden is an important technique for evaluation of sterility doses for medical devices. However, many studies have been done mainly on the irradiation effects of spore-forming bacteria in medical devices. In this study, radiation sensitivity of spore-forming bacteria and fungi were examined after the survey on distribution of microorganisms in several kinds of medical devices. The main contaminant in disposable syringes, needles and conical flasks were consisted of Bacillus, with lesser amount of Micrococcus, Pseudomonas, Peptococcaceae and fungi as positive of 5 - 60 % in the medical devices which cultivated in thioglycolate broth. Bacillus group were identified as B. pumilus, B. sphaericus, B. coagulans, B. megaterium and etc. Fungi were isolated a lesser amounts compared with spore-forming bacteria and identified as Blastomyces, Penicillium, Haplosporangium, Euricoa and Audeobasidium. Peptococaceae were not isolated after irradiation with a dose of 0.1 Mrad even the samples were contaminated with high percentage. The D 10 values of dryed endospores of Bacillus-isolates which attached to the filter paper with pepton-glycerin were obtained to be 0.11 - 0.19 Mrad. The D 10 values of many isolates of fungi in dry condition were obtained below 0.08 Mrad. However, the isolate of Aureobasidium is radiation-resistant, and it's D 10 values was obtained as 0.28 Mrad under aerobic and anaerobic dry condition. (author)

  4. 78 FR 16684 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2013-03-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  5. 77 FR 20642 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2012-04-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  6. 76 FR 14415 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-03-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  7. 76 FR 62419 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-10-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  8. 75 FR 49940 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2010-08-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  9. 78 FR 30928 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2013-05-23

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  10. 76 FR 39882 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-07-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0478] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  11. Design considerations for medical devices in the home environment.

    Science.gov (United States)

    Kaufman-Rivi, Diana; Collins-Mitchell, Janette; Jetley, Raoul

    2010-01-01

    Patient demographics, economic forces, and technological advancements contribute to the rise in home care services. Advanced medical devices and equipment originally designed for use by trained personnel in hospitals and clinics are increasingly migrating into the home. Unlike the clinical setting, the home is an uncontrolled environment with additional hazards. The compatibility of the device with the recipient's knowledge, abilities, lifestyle, and home environment plays a significant role in their therapy and rehabilitation. The advent of new device technologies such as wireless devices and interoperability of systems lends a new and complex perspective for medical device use in the home that must also be addressed. Adequately assessing and matching the patient and their caregiver with the appropriate device technology while considering the suitability of the home environment for device operation and maintenance is a challenge that relies on good human factors principles. There is a need to address these challenges in the growing home care sector In this article, the authors take a look at some important considerations and design issues for medical devices used in the home care environment.

  12. Development of a handmade device for collimation and central ray alignment tests in medical X-ray equipment

    International Nuclear Information System (INIS)

    Cruz, B.L. da; Brito, E.B.; Gomes, A.S.

    2017-01-01

    Ordinance 453/98 of the Ministry of Health establishes that medical X-ray equipment should be monitored by tests that prove its efficiency. This practice is called quality control (QC), and two important tests jointly evaluate the operation of the collimation and alignment systems of the central axis of the X-ray beam. The low supply and the high cost generate allegations of difficulties in the periodic realization of the tests. The aim of this work is to design, make and evaluate the performance of a handmade device for the mentioned tests, using low cost materials. Once built, the device had its performance evaluated and compared with the traditionally marketed device. The handmade device proved to be fit in its functions. It is possible to make a device that tests X-ray medical equipment, using the radiology technologist himself as the test runner. Radiation protection is promoted and legislation with no real financial burden

  13. Implantable Medical Devices; Networking Security Survey

    Directory of Open Access Journals (Sweden)

    Siamak Aram

    2016-08-01

    Full Text Available The industry of implantable medical devices (IMDs is constantly evolving, which is dictated by the pressing need to comprehensively address new challenges in the healthcare field. Accordingly, IMDs are becoming more and more sophisticated. Not long ago, the range of IMDs’ technical capacities was expanded, making it possible to establish Internet connection in case of necessity and/or emergency situation for the patient. At the same time, while the web connectivity of today’s implantable devices is rather advanced, the issue of equipping the IMDs with sufficiently strong security system remains unresolved. In fact, IMDs have relatively weak security mechanisms which render them vulnerable to cyber-attacks that compromise the quality of IMDs’ functionalities. This study revolves around the security deficiencies inherent to three types of sensor-based medical devices; biosensors, insulin pump systems and implantable cardioverter defibrillators. Manufacturers of these devices should take into consideration that security and effectiveness of the functionality of implants is highly dependent on the design. In this paper, we present a comprehensive study of IMDs’ architecture and specifically investigate their vulnerabilities at networking interface.

  14. Early-stage valuation of medical devices: the role of developmental uncertainty.

    Science.gov (United States)

    Girling, Alan; Young, Terry; Brown, Celia; Lilford, Richard

    2010-08-01

    At the concept stage, many uncertainties surround the commercial viability of a new medical device. These include the ultimate functionality of the device, the cost of producing it and whether, and at what price, it can be sold to a health-care provider (HCP). Simple assessments of value can be made by estimating such unknowns, but the levels of uncertainty may mean that their operational value for investment decisions is unclear. However, many decisions taken at the concept stage are reversible and will be reconsidered later before the product is brought to market. This flexibility can be exploited to enhance early-stage valuations. To develop a framework for valuing a new medical device at the concept stage that balances benefit to the HCP against commercial costs. This is done within a simplified stage-gated model of the development cycle for new products. The approach is intended to complement existing proposals for the evaluation of the commercial headroom available to new medical products. A model based on two decision gates can lead to lower bounds (underestimates) for product value that can serve to support a decision to develop the product. Quantifiable uncertainty that can be resolved before the device is brought to market will generally enhance early-stage valuations of the device, and this remains true even when some components of uncertainty cannot be fully described. Clinical trials and other evidence-gathering activities undertaken as part of the development process can contribute to early-stage estimates of value.

  15. Medical instruments and devices principles and practices

    CERN Document Server

    Schreiner, Steven; Peterson, Donald R

    2015-01-01

    Medical Instruments and Devices: Principles and Practices originates from the medical instruments and devices section of The Biomedical Engineering Handbook, Fourth Edition. Top experts in the field provide material that spans this wide field. The text examines how biopotential amplifiers help regulate the quality and content of measured signals. It includes instruments and devices that span a range of physiological systems and the physiological scale: molecular, cellular, organ, and system. The book chronicles the evolution of pacemakers and their system operation and discusses oscillometry, cardiac output measurement, and the direct and indirect methods of measuring cardiac output. The authors also expound on the mechanics and safety of defibrillators and cover implantable stimulators, respiration, and the structure and function of mechanical ventilators. In addition, this text covers in depth: Anesthesia Delivery Electrosurgical Units and Devices Biomedical Lasers Measuring Cellular Traction Forces Blood G...

  16. Innovative medical devices and hospital decision making: a study comparing the views of hospital pharmacists and physicians.

    Science.gov (United States)

    Billaux, Mathilde; Borget, Isabelle; Prognon, Patrice; Pineau, Judith; Martelli, Nicolas

    2016-06-01

    Objectives Many university hospitals have developed local health technology assessment processes to guide informed decisions about new medical devices. However, little is known about stakeholders' perceptions and assessment of innovative devices. Herein, we investigated the perceptions regarding innovative medical devices of their chief users (physicians and surgeons), as well as those of hospital pharmacists, because they are responsible for the purchase and management of sterile medical devices. We noted the evaluation criteria used to assess and select new medical devices and suggestions for improving local health technology assessment processes indicated by the interviewees. Methods We randomly selected 18 physicians and surgeons (nine each) and 18 hospital pharmacists from 18 French university hospitals. Semistructured interviews were conducted between October 2012 and August 2013. Responses were coded separately by two researchers. Results Physicians and surgeons frequently described innovative medical devices as 'new', 'safe' and 'effective', whereas hospital pharmacists focused more on economic considerations and considered real innovative devices to be those for which no equivalent could be found on the market. No significant difference in evaluation criteria was found between these groups of professionals. Finally, hospital pharmacists considered the management of conflicts of interests in local health technology assessment processes to be an issue, whereas physicians and surgeons did not. Conclusions The present study highlights differences in perceptions related to professional affiliation. The findings suggest several ways in which current practices for local health technology assessment in French university hospitals could be improved and studied. What is known about the topic? Hospitals are faced with ever-growing demands for innovative and costly medical devices. To help hospital management deal with technology acquisition issues, hospital

  17. Use of endpoint adjudication to improve the quality and validity of endpoint assessment for medical device development and post marketing evaluation: Rationale and best practices. A report from the cardiac safety research consortium.

    Science.gov (United States)

    Seltzer, Jonathan H; Heise, Ted; Carson, Peter; Canos, Daniel; Hiatt, Jo Carol; Vranckx, Pascal; Christen, Thomas; Cutlip, Donald E

    2017-08-01

    This white paper provides a summary of presentations, discussions and conclusions of a Thinktank entitled "The Role of Endpoint Adjudication in Medical Device Clinical Trials". The think tank was cosponsored by the Cardiac Safety Research Committee, MDEpiNet and the US Food and Drug Administration (FDA) and was convened at the FDA's White Oak headquarters on March 11, 2016. Attention was focused on tailoring best practices for evaluation of endpoints in medical device clinical trials, practical issues in endpoint adjudication of therapeutic, diagnostic, biomarker and drug-device combinations, and the role of adjudication in regulatory and reimbursement issues throughout the device lifecycle. Attendees included representatives from medical device companies, the FDA, Centers for Medicare and Medicaid Services (CMS), end point adjudication specialist groups, clinical research organizations, and active, academically based adjudicators. The manuscript presents recommendations from the think tank regarding (1) rationale for when adjudication is appropriate, (2) best practices establishment and operation of a medical device adjudication committee and (3) the role of endpoint adjudication for post market evaluation in the emerging era of real world evidence. Copyright © 2017. Published by Elsevier Inc.

  18. Instructions included? Make safety training part of medical device procurement process.

    Science.gov (United States)

    Keller, James P

    2010-04-01

    Before hospitals embrace new technologies, it's important that medical personnel agree on how best to use them. Likewise, hospitals must provide the support to operate these sophisticated devices safely. With this in mind, it's wise for hospitals to include medical device training in the procurement process. Moreover, purchasing professionals can play a key role in helping to increase the amount of user training for medical devices and systems. What steps should you take to help ensure that new medical devices are implemented safely? Here are some tips.

  19. The potential of medical device industry in technological and economical context.

    Science.gov (United States)

    Maresova, Petra; Penhaker, Marek; Selamat, Ali; Kuca, Kamil

    2015-01-01

    The high quality of public health improves not only healthy life expectancy, but also the productivity of labor. The most important part of the health care sector is the medical technology industry. The aim of this study is to analyze the current situation in the medical device industry in Europe, its potential strengths and weaknesses in the context of topical economic and demographic development. The contribution specifies an analysis of the economic state of the medical device industry in the context of demographic development of European Union's macroeconomic indicators and views of experts in the field of medical device development, concerning the opportunities for entities involved in the medical device market. There is fierce competition on the European market. The innovative activity is stable and well regulated by responsible authorities. Worldwide, the medical device market is expected to grow.

  20. 77 FR 14272 - Medical Devices; Immunology and Microbiology Devices; Classification of Norovirus Serological...

    Science.gov (United States)

    2012-03-09

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 866 [Docket No. FDA-2012-N-0165] Medical Devices; Immunology and Microbiology Devices; Classification of Norovirus... AND MICROBIOLOGY DEVICES 0 1. The authority citation for 21 CFR part 866 continues to read as follows...

  1. Value-based procurement of medical devices: Application to devices for mechanical thrombectomy in ischemic stroke.

    Science.gov (United States)

    Trippoli, Sabrina; Caccese, Erminia; Marinai, Claudio; Messori, Andrea

    2018-03-01

    In the acute ischemic stroke, endovascular devices have shown promising clinical results and are also likely to represent value for money, as several modeling studies have shown. Pharmacoeconomic evaluations in this field, however, have little impact on the procurement of these devices. The present study explored how complex pharmacoeconomic models that evaluate effectiveness and cost can be incorporated into the in-hospital procurement of thrombectomy devices. As regards clinical modeling, we extracted outcomes at three months from randomized trials conducted for four thrombectomy devices, and we projected long-term results using standard Markov modeling. In estimating QALYs, the same model was run for the four devices. As regards economic modeling, we firstly estimated for each device the net monetary benefit (NMB) per patient (threshold = $60,000 per QALY); then, we simulated a competitive tender across the four products by determining the tender-based score (on a 0-to-100 scale). Prices of individual devices were obtained from manufacturers. Extensive sensitivity testing was applied to our analyses. For the four devices (Solitaire, Trevo, Penumbra, Solumbra), QALYs were 1.86, 1.52, 1,79, 1.35, NMB was $101,824, $83,546, $101,923, $69,440, and tender-based scores were 99.70, 43.43, 100, 0, respectively. Sensitivity analysis confirmed findings from base-case. Our results indicate that, in the field of thrombectomy devices, incorporating the typical tools of cost-effectiveness into the processes of tenders and procurement is feasible. Bridging the methodology of cost-effectiveness with the every-day practice of in-hospital procurement can contribute to maximizing the health returns that are generated by in-hospital expenditures for medical devices. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Regulatory affairs for biomaterials and medical devices

    CERN Document Server

    Amato, Stephen F; Amato, B

    2015-01-01

    All biomaterials and medical devices are subject to a long list of regulatory practises and policies which must be adhered to in order to receive clearance. This book provides readers with information on the systems in place in the USA and the rest of the world. Chapters focus on a series of procedures and policies including topics such as commercialization, clinical development, general good practise manufacturing and post market surveillance.Addresses global regulations and regulatory issues surrounding biomaterials and medical devicesEspecially useful for smaller co

  3. Medical Device-Associated Candida Infections in a Rural Tertiary Care Teaching Hospital of India

    Directory of Open Access Journals (Sweden)

    Sachin C. Deorukhkar

    2016-01-01

    Full Text Available Health care associated infections (HCAIs add incrementally to the morbidity, mortality, and cost expected of the patient’s underlying diseases alone. Approximately, about half all cases of HCAIs are associated with medical devices. As Candida medical device-associated infection is highly drug resistant and can lead to serious life-threatening complications, there is a need of continuous surveillance of these infections to initiate preventive and corrective measures. The present study was conducted at a rural tertiary care hospital of India with an aim to evaluate the rate of medical device-associated Candida infections. Three commonly encountered medical device-associated infections (MDAI, catheter-associated urinary tract infection (CA-UTI, intravascular catheter-related blood stream infections (CR-BSI, and ventilator-associated pneumonia (VAP, were targeted. The overall rate of MDAI in our hospital was 2.1 per 1000 device days. The rate of Candida related CA-UTI and CR-BSI was noted as 1.0 and 0.3, respectively. Untiring efforts taken by team members of Hospital Acquired Infection Control Committee along with maintenance of meticulous hygiene of the hospital and wards may explain the low MDAI rates in our institute. The present surveillance helped us for systematic generation of institutional data regarding MDAI with special reference to role of Candida spp.

  4. Growing pains: medical device interoperability. Regulators and new standards are helping to bring about the convergence of medical devices and information management systems on IT networks.

    Science.gov (United States)

    Degaspari, John

    2011-07-01

    Both provider organizations and medical device vendors have made significant, if slow-going, progress over the last several years to network their digitally-enabled medical devices. Recent strides in both the regulatory and standards arenas have provided renewed impetus on the part of both stakeholder groups to bring more interoperability to disparate medical devices, resulting in better security and quality of patient data.

  5. 78 FR 18233 - Medical Devices; Technical Amendment

    Science.gov (United States)

    2013-03-26

    ... human environment. Therefore, neither an environmental assessment nor an environmental impact statement..., Confidential business information, Medical devices, Medical research, Reporting and recordkeeping requirements... revising the second sentence in paragraph (a) to read as follows: Sec. 870.3600 External pacemaker pulse...

  6. 76 FR 65200 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee: Notice of...

    Science.gov (United States)

    2011-10-20

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee: Notice of... Administration (FDA) is postponing the meeting of the General and Plastic Surgery Devices Panel of the Medical...

  7. Prospects of radiation sterilization of medical devices

    International Nuclear Information System (INIS)

    Hosobuchi, Kazunari

    1992-01-01

    Since radiation sterilization was first introduced in the United States in 1956 in the field of disposable medical devices, it has become an indispensable technique for sterilization because of the following reasons: (1) introduction into dialyzers, (2) introduction in medical device makers, (3) development of disposable medical devices associated with developing both high molecular chemistry and cool sterilization, (4) rationality of sterilization process, and (5) problems of sterilization with ethylene oxide gas. To promote the further development of radiation sterilization, the following items are considered necessary: (1) an increase in the number of facilities for radiation sterilization, (2) recommendation of the international standardization of sterilization method, (3) decrease in radiation doses associated with sterilization, (4) development of electron accelerators and bremsstrahlung equipments for radiation sources, and (5) simplification of sterilization process management. Factors precluding the development of radiation sterilization are: (1) development of other methods than radiation sterilization, (2) development of technique for sterile products, (3) high facility cost, (4) high irradiation cost, (5) benefits and limits of sterilization markets, and (6) influences of materials. (N.K.)

  8. Assurance Cases for Medical Devices

    Science.gov (United States)

    2011-04-28

    the patient, and the hospital setting. Some pumps allow the patient to control part of the injection process (e.g. to inject more painkiller ...overdose, incorrect therapy, etc.   Design and development decisions that bear on safety and effectiveness http://www.fda.gov/MedicalDevices

  9. Electronic medical devices: a primer for pathologists.

    Science.gov (United States)

    Weitzman, James B

    2003-07-01

    Electronic medical devices (EMDs) with downloadable memories, such as implantable cardiac pacemakers, defibrillators, drug pumps, insulin pumps, and glucose monitors, are now an integral part of routine medical practice in the United States, and functional organ replacements, such as the artificial heart, pancreas, and retina, will most likely become commonplace in the near future. Often, EMDs end up in the hands of the pathologist as a surgical specimen or at autopsy. No established guidelines for systematic examination and reporting or comprehensive reviews of EMDs currently exist for the pathologist. To provide pathologists with a general overview of EMDs, including a brief history; epidemiology; essential technical aspects, indications, contraindications, and complications of selected devices; potential applications in pathology; relevant government regulations; and suggested examination and reporting guidelines. Articles indexed on PubMed of the National Library of Medicine, various medical and history of medicine textbooks, US Food and Drug Administration publications and product information, and specifications provided by device manufacturers. Studies were selected on the basis of relevance to the study objectives. Descriptive data were selected by the author. Suggested examination and reporting guidelines for EMDs received as surgical specimens and retrieved at autopsy. Electronic medical devices received as surgical specimens and retrieved at autopsy are increasing in number and level of sophistication. They should be systematically examined and reported, should have electronic memories downloaded when indicated, will help pathologists answer more questions with greater certainty, and should become an integral part of the formal knowledge base, research focus, training, and practice of pathology.

  10. Wearable Devices in Medical Internet of Things: Scientific Research and Commercially Available Devices.

    Science.gov (United States)

    Haghi, Mostafa; Thurow, Kerstin; Stoll, Regina

    2017-01-01

    Wearable devices are currently at the heart of just about every discussion related to the Internet of Things. The requirement for self-health monitoring and preventive medicine is increasing due to the projected dramatic increase in the number of elderly people until 2020. Developed technologies are truly able to reduce the overall costs for prevention and monitoring. This is possible by constantly monitoring health indicators in various areas, and in particular, wearable devices are considered to carry this task out. These wearable devices and mobile apps now have been integrated with telemedicine and telehealth efficiently, to structure the medical Internet of Things. This paper reviews wearable health care devices both in scientific papers and commercial efforts. MIoT is demonstrated through a defined architecture design, including hardware and software dealing with wearable devices, sensors, smart phones, medical application, and medical station analyzers for further diagnosis and data storage. Wearables, with the help of improved technology have been developed greatly and are considered reliable tools for long-term health monitoring systems. These are applied in the observation of a large variety of health monitoring indicators in the environment, vital signs, and fitness. Wearable devices are now used for a wide range of healthcare observation. One of the most important elements essential in data collection is the sensor. During recent years with improvement in semiconductor technology, sensors have made investigation of a full range of parameters closer to realization.

  11. The Style Evolution of Glasses: Acknowledging Well-being for Wearable Medical Device

    Directory of Open Access Journals (Sweden)

    Lydia Royeen

    2015-10-01

    Full Text Available The focus of Peta Bush’s work is to create wearable medical devices that address all qualities of the individual, including physical, mental, emotional, and psychosocial aspects. Peta is completing a practice-based research PhD titled “Therapeutic jewelry: The craft of people-centric devices for wellbeing.” Her passion for creating wearable medical devices that are multi-dimensional stems from her personal experiences, as she has Ehlers-Danlos syndrome. In addition, she uses her knowledge of well-being and the biopsychosocial model when creating her wearable medical devices. Peta currently uses technology, such as 3D printing, as one method to fabricate her collection. Her aspirations are for this concept of wearable medical devices to become mainstream, similar to glasses, and to remove the stigma associated with wearable medical devices.

  12. 78 FR 12329 - Distinguishing Medical Device Recalls From Product Enhancements; Reporting Requirements; Draft...

    Science.gov (United States)

    2013-02-22

    ... medical devices to take timely action to correct violative devices or remove them from the marketplace...] Distinguishing Medical Device Recalls From Product Enhancements; Reporting Requirements; Draft Guidance for... draft guidance entitled ``Distinguishing Medical Device Recalls From Product Enhancements; Reporting...

  13. [Thoughts on the Witnessed Audit in Medical Device Single Audit Program].

    Science.gov (United States)

    Wen, Jing; Xiao, Jiangyi; Wang, Aijun

    2018-02-08

    Medical Device Single Audit Program is one of the key projects in International Medical Device Regulators Forum, which has much experience to be used for reference. This paper briefly describes the procedures and contents of the Witnessed Audit in Medical Device Single Audit Program. Some revelations about the work of Witnessed Audit have been discussed, for reference by the Regulatory Authorities and the Auditing Organizations.

  14. Pre-market approval and post-market direct-to-consumer advertising of medical devices in Australia: a case study of breast cancer screening and diagnostic devices.

    Science.gov (United States)

    Vreugdenburg, T D; Willis, C D; Mundy, L; Hiller, J E

    2013-01-01

    While research investigating direct-to-consumer advertising of therapeutic goods in Australia has historically focused on prescription medicines, recent action taken by regulators against companies promoting medical devices has placed the industry into the spotlight. Despite the need to effectively regulate direct-to-consumer advertising of medical devices due to its potential harms, inadequacies in the current regulatory system have been noted. Under the present system, devices with a questionable evidence base may enter the Australian marketplace without an evaluation of their effectiveness, and regulators are reliant on industry self-regulation and consumer complaints to draw attention to cases of advertising misconduct. Although some successes in the present system have been observed, we argue that the outlined inadequacies continue to enable the promotion of medical devices to consumers without thorough or sufficient examination of evidence. © 2011 The Authors; Internal Medicine Journal © 2011 Royal Australasian College of Physicians.

  15. Medical device development: managing conflicts of interest encountered by physicians.

    Science.gov (United States)

    Baim, Donald S; Donovan, Aine; Smith, John J; Briefs, Nancy; Geoffrion, Richard; Feigal, David; Kaplan, Aaron V

    2007-04-01

    New technologies introduced over the past three decades have transformed medical diagnosis and treatment, and significantly improved patient outcomes. These changes have been mediated by the introduction of new medical devices, particularly for the treatment of cardiovascular, orthopedic, and ophthalmic disorders. These devices, in turn, have created large markets and spawned a burgeoning medical device industry, including six Fortune 500 companies whose combined market capitalization now exceeds 400 billion dollars. This success story, which has unquestionably benefited patients and society alike, has been dependent upon an intense collaboration among industry, clinicians, and regulatory authorities. However, when physicians actively involved in patient care participate in such collaborations, they are increasingly vulnerable to creating potential conflicts between these two (clinical and device development) roles. Such conflicts, which may ultimately erode public trust, have important consequences not only for the individual physicians, but also for their parent institutions, their patients, sponsoring companies, and the entire clinical research enterprise that makes the development and introduction of new devices possible. The third Dartmouth Device Development Symposium held in October 2005 brought together thought leaders within the medical device community, including academicians, clinical investigators, regulators from the Food and Drug Administration and Centers for Medicare and Medicaid Services (CMS), large and small device manufacturers and the financial (venture capital and investment banks) community. The Symposium examined the conflicts of interest encountered during the early development and commercialization of a medical device. The goal of these discussions was to (1) identify and characterize the conflicts that arise and (2) provide strategies to address these conflicts. This manuscript was prepared by a writing committee to provide a summary

  16. 75 FR 68200 - Medical Devices; Radiology Devices; Reclassification of Full-Field Digital Mammography System

    Science.gov (United States)

    2010-11-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 892 [Docket No. FDA-2008-N-0273] Medical Devices; Radiology Devices; Reclassification of Full- Field Digital... and Drugs, 21 CFR part 892 is amended as follows: PART 892--RADIOLOGY DEVICES 0 1. The authority...

  17. Identification of Bodies by Unique Serial Numbers on Implanted Medical Devices.

    Science.gov (United States)

    Blessing, Melissa M; Lin, Peter T

    2018-05-01

    Visual identification is the most common identification method used by medical examiners but is not always possible. Alternative methods include X-ray, fingerprint, or DNA comparison, but these methods require additional resources. Comparison of serial numbers on implanted medical devices is a rapid and definitive method of identification. To assess the practicality of using this method, we reviewed 608 consecutive forensic autopsies performed at a regional medical examiner office. Of these, 56 cases required an alternative method of identification due to decomposition (n = 35), gunshot wound (n = 9), blunt trauma (n = 6), or charring (n = 6). Of these 56 cases, eight (14.3%) were known to have an implanted medical device. Of these eight cases, five (63%) could be positively identified by comparing serial numbers. If an implanted medical device is known to be present, and medical records are available, identification by medical device serial number should be a first-line method. © 2017 American Academy of Forensic Sciences.

  18. Medical applications for pharmacists using mobile devices.

    Science.gov (United States)

    Aungst, Timothy Dy

    2013-01-01

    Mobile devices (eg, smartphones, tablet computers) have become ubiquitous and subsequently there has been a growth in mobile applications (apps). Concurrently, mobile devices have been integrated into health care practice due to the availability and quality of medical apps. These mobile medical apps offer increased access to clinical references and point-of-care tools. However, there has been little identification of mobile medical apps suitable for the practice of pharmacy. To address the shortage of recommendations of mobile medical apps for pharmacists in daily practice. Mobile medical apps were identified via the iTunes and Google Play Stores via the "Medical" app categories and key word searches (eg, drug information, medical calculators). In addition, reviews provided by professional mobile medical app review websites were used to identify apps. Mobile medical apps were included if they had been updated in the previous 3 months, were available in the US, used evidence-based information or literature support, had dedicated app support, and demonstrated stability. Exclusion criteria included apps that were not available in English, had advertisement bias, used nonreferenced sources, were available only via an institution-only subscription, and were web-based portals. Twenty-seven mobile apps were identified and reviewed that involved general pharmacy practice, including apps that involved drug references, clinical references, medical calculators, laboratory references, news and continuing medical education, and productivity. Mobile medical apps have a variety of features that are beneficial to pharmacy practice. Individual clinicians should consider several characteristics of these apps to determine which are suitable to incorporate into their daily practice.

  19. Developing medical device software in compliance with regulations.

    Science.gov (United States)

    Zema, M; Rosati, S; Gioia, V; Knaflitz, M; Balestra, G

    2015-08-01

    In the last decade, the use of information technology (IT) in healthcare has taken a growing role. In fact, the adoption of an increasing number of computer tools has led to several benefits related to the process of patient care and allowed easier access to social and health care resources. At the same time this trend gave rise to new challenges related to the implementation of these new technologies. Software used in healthcare can be classified as medical devices depending on the way they are used and on their functional characteristics. If they are classified as medical devices they must satisfy specific regulations. The aim of this work is to present a software development framework that can allow the production of safe and high quality medical device software and to highlight the correspondence between each software development phase and the appropriate standard and/or regulation.

  20. 21 CFR 801.122 - Medical devices for processing, repacking, or manufacturing.

    Science.gov (United States)

    2010-04-01

    ....122 Medical devices for processing, repacking, or manufacturing. A device intended for processing... act if its label bears the statement “Caution: For manufacturing, processing, or repacking”. ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical devices for processing, repacking, or...

  1. Handheld Diagnostic Device Delivers Quick Medical Readings

    Science.gov (United States)

    2014-01-01

    To monitor astronauts' health remotely, Glenn Research Center awarded SBIR funding to Cambridge, Massachusetts-based DNA Medical Institute, which developed a device capable of analyzing blood cell counts and a variety of medical biomarkers. The technology will prove especially useful in rural areas without easy access to labs.

  2. Medical device problem reporting for the betterment of healthcare.

    Science.gov (United States)

    1998-08-01

    Given that there are nearly 5,000 individual classes of medical devices, tens of thousands of medical device suppliers, and millions of healthcare providers around the world, device-related problems are bound to happen. But effective problem reporting can help reduce or eliminate many of these problems--not only within an institution, but also potentially around the world. In this article, we trace the problem reporting process from its beginnings in the hospital to its global impact in making critical information available throughout the healthcare community.

  3. Home Healthcare Medical Devices: A Checklist

    Science.gov (United States)

    ... not using it. Contact your doctor and home healthcare team often to review your health condition. * Check ... assurance of their safety and effectiveness. A home healthcare medical device is any product or equipment used ...

  4. Post-market clinical research conducted by medical device manufacturers: a cross-sectional survey

    Directory of Open Access Journals (Sweden)

    Ross JS

    2015-05-01

    Full Text Available Joseph S Ross, Katrina L Blount, Jessica D Ritchie, Beth Hodshon, Harlan M Krumholz Center for Outcomes Research and Evaluation, Yale-New Haven Hospital, New Haven, CT, USA Background: In the US, once a medical device is made available for use, several requirements have been established by the US Food and Drug Administration (FDA to ensure ongoing post-market surveillance of device safety and effectiveness. Our objective was to determine how commonly medical device manufacturers initiate post-market clinical studies or augment FDA post-market surveillance requirements for higher-risk devices that are most often approved via the FDA's pre-market approval (PMA pathway. Methods and results: We conducted a cross-sectional survey of 47 manufacturers with operations in California, Minnesota, and Massachusetts who market devices approved via the PMA pathway. Among 22 respondents (response rate =47%, nearly all self-reported conducting post-market clinical research studies, commonly between 1 and 5; only 1 respondent reported never conducting post-market clinical research studies. While manufacturers most often engaged in these studies to satisfy FDA requirements, other reasons were reported, including performance monitoring and surveillance and market acceptance initiatives. Risks of conducting and not conducting post-market clinical research studies were described through open-ended response to questions. Conclusion: Medical device manufacturers commonly initiate post-market clinical studies at the request of the FDA. Clinical data from these studies should be integrated into national post-market surveillance initiatives. Keywords: FDA, PMA pathway, post-market surveillance

  5. Radiation sterilization of medical devices

    International Nuclear Information System (INIS)

    Kaluska, I.; Stuglik, Z.

    1996-01-01

    Overview of sterilization methods of medical devices has been given, with the special stress put on radiation sterilization. A typical validation program for radiation sterilization has been shown and also a comparison of European and ISO standards concerning radiation sterilization has been discussed. (author). 13 refs, 1 fig., 2 tabs

  6. 77 FR 19534 - Medical Devices; Immunology and Microbiology Devices; Classification of Norovirus Serological...

    Science.gov (United States)

    2012-04-02

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 866 [Docket No. FDA-2012-N-0165] Medical Devices; Immunology and Microbiology Devices; Classification of Norovirus Serological Reagents; Correction AGENCY: Food and Drug Administration, HHS. ACTION: Final rule; correction...

  7. BIOANALYTICAL STANDARDIZING FOR SEROLOGICAL DIAGNOSTIC MEDICAL DEVICES

    Directory of Open Access Journals (Sweden)

    A. Yu. Galkin

    2015-04-01

    Full Text Available In article we analyzed national and international regulations concerning the quality and safety of medical devices for in vitro diagnostics. We discussed the possibility of a partial application of the recommendations of the State Pharmacopoeia of Ukraine to this type of product. The main guiding regulatory documents establishing requirements for quality and safety tools for the serological diagnosis products are The technical regulation on medical devices for the diagnosis in vitro, DSTU ISO 13485 “Medical devices. Quality management system. Regulatory requirements”, and DSTU ISO/IEC 17025 “General requirements for the competence of testing and calibration laboratories”. Similar requirements of the State Pharmacopoeia of Ukraine which are used for drug standardization can not be directly applied to the medical devises for in vitro diagnostics due to a number of features, namely, the serological diagnosis products pre-designed to determine the unknown concentration of a particular analyte in a biological material, the diagnostic kits has to include the control samples (internal standard systems that need to be calibrated. It was determined following parameters of bioanalytical standardization and validation characterization for of qualitative (semi quantitative test-kits for serological diagnosis: precision (convergence, intralaboratory precision and reproducibility, diagnostic and analytical specificity, diagnostic sensitivity. It’s necessary to inspect additional parameters for quantitative test-kits such as accuracy (precision, linearity, analytical sensitivity and range.

  8. Liability for damage caused by shortage and failure to use necessary medical devices

    Directory of Open Access Journals (Sweden)

    Cvetković Mihajlo

    2014-01-01

    Full Text Available In order to provide for successful, safe and high quality medical services, health care institutions need to be equipped with adequate medical devices. For this reason, every medical institution is legally obliged to have relevant medical devices. In case a patient has been deprived of some medical service for the lack of necessary medical devices (which the institution has been obliged to provide, the medical institution is responsible for the damage and harm sustained by the patient. The responsibility implies non-contractual liability (in tort law or pre-contractual liability (in contract law. In both cases, the liability is based on the presumed culpability. In order to be excluded from liability, the medical institution has to prove that the patient has been deprived of medical service (or that the institution has refused to enter into a medical service provider agreement on justifiable grounds, i.e. due to the lack of necessary medical devices. On the other hand, in case the medial institutions fail to provide needed care or violate their obligation to use medical devices when necessary, it is regarded as medical negligence (professional error. In most cases, it implies the liability of medical institutions for damage, injury or harm caused to the patient by medical services provided without applying a relevant medical device, whose use has been medically indicated. The liability is even more substantial in cases where the medical device has been available but the medical institutions has not applied it in medial treatment (even though its use has been medically indicated; such conduct is qualified as gross negligence.

  9. Medical Device Plug-and-Play Interoperability Standards and Technology Leadership

    Science.gov (United States)

    2017-10-01

    Award Number: W81XWH-09-1-0705 TITLE: “Medical Device Plug-and-Play Interoperability Standards and Technology Leadership” PRINCIPAL INVESTIGATOR...Sept 2016 – 20 Sept 2017 4. TITLE AND SUBTITLE “Medical Device Plug-and-Play Interoperability 5a. CONTRACT NUMBER Standards and Technology ...efficiency through interoperable medical technologies . We played a leadership role on interoperability safety standards (AAMI, AAMI/UL Joint

  10. Transmitting patient and device data via GSM--central management for decentral mobile medical devices.

    Science.gov (United States)

    Bachmor, T; Schöchlin, J; Bolz, A

    2002-01-01

    Equipping medical devices with long range telemetry opens completely new possibilities for emergency response, home care and remote diagnosis. Mobile communications nowadays seem to be a generally accepted part of our modern world, but bridging the gap between new (consumer-) technologies and medical devices still is a challenge today. Providing a telemetry link (GSM) is just the trivial part--ensuring security, reliability and service management are the more critical tasks that need to be addressed. Therefore, a complete system concept consists of an automatic fleet management (e.g. periodic device-initiated service calls) as well as customer relationship management (CRM), including technical service and a trouble-ticket system.

  11. Medical device integration: CIOs must bridge the digital divide between devices and electronic medical records.

    Science.gov (United States)

    Raths, David

    2009-02-01

    To get funding approved for medical device integration, ClOs suggest focusing on specific patient safety or staff efficiency pain points. Organizations that make clinical engineering part of their IT team report fewer chain-of-command issues. It also helps IT people understand the clinical goals because the engineering people have been working closely with clinicians for years. A new organization has formed to work on collaboration between clinical engineers and IT professionals. For more information, go to www.ceitcollaboration.org. ECRI Institute has written a guide to handling the convergence of medical technology and hospital networks. Its "Medical Technology for the IT Professional: An Essential Guide for Working in Today's Healthcare Setting" also details how IT professionals can assist hospital technology planning and acquisition, and provide ongoing support for IT-based medical technologies. For more information, visit www.ecri.org/ITresource.

  12. Human Thiel-Embalmed Cadaveric Aortic Model with Perfusion for Endovascular Intervention Training and Medical Device Evaluation.

    Science.gov (United States)

    McLeod, Helen; Cox, Ben F; Robertson, James; Duncan, Robyn; Matthew, Shona; Bhat, Raj; Barclay, Avril; Anwar, J; Wilkinson, Tracey; Melzer, Andreas; Houston, J Graeme

    2017-09-01

    The purpose of this investigation was to evaluate human Thiel-embalmed cadavers with the addition of extracorporeal driven ante-grade pulsatile flow in the aorta as a model for simulation training in interventional techniques and endovascular device testing. Three human cadavers embalmed according to the method of Thiel were selected. Extracorporeal pulsatile ante-grade flow of 2.5 L per min was delivered directly into the aorta of the cadavers via a surgically placed connection. During perfusion, aortic pressure and temperature were recorded and optimized for physiologically similar parameters. Pre- and post-procedure CT imaging was conducted to plan and follow up thoracic and abdominal endovascular aortic repair as it would be in a clinical scenario. Thoracic endovascular aortic repair (TEVAR) and endovascular abdominal repair (EVAR) procedures were conducted in simulation of a clinical case, under fluoroscopic guidance with a multidisciplinary team present. The Thiel cadaveric aortic perfusion model provided pulsatile ante-grade flow, with pressure and temperature, sufficient to conduct a realistic simulation of TEVAR and EVAR procedures. Fluoroscopic imaging provided guidance during the intervention. Pre- and post-procedure CT imaging facilitated planning and follow-up evaluation of the procedure. The human Thiel-embalmed cadavers with the addition of extracorporeal flow within the aorta offer an anatomically appropriate, physiologically similar robust model to simulate aortic endovascular procedures, with potential applications in interventional radiology training and medical device testing as a pre-clinical model.

  13. Cybersecurity and medical devices: A practical guide for cardiac electrophysiologists

    Science.gov (United States)

    Kramer, Daniel B.; Foo Kune, Denis; Auto de Medeiros, Julio; Yan, Chen; Xu, Wenyuan; Crawford, Thomas; Fu, Kevin

    2017-01-01

    Abstract Medical devices increasingly depend on software. While this expands the ability of devices to perform key therapeutic and diagnostic functions, reliance on software inevitably causes exposure to hazards of security vulnerabilities. This article uses a recent high‐profile case example to outline a proactive approach to security awareness that incorporates a scientific, risk‐based analysis of security concerns that supports ongoing discussions with patients about their medical devices. PMID:28512774

  14. Medical device registration, agreements on mutual recognition - a step forward to global harmonization?

    International Nuclear Information System (INIS)

    Eidenberger, R.Reiner

    2000-01-01

    The purpose of this article is to give a short overview of some different regulations in Europe and the United States with regard to the clearance of medical devices and to give an outlook of what the Agreements on Mutual Recognition will bring in terms of Global Harmonization. Recent European legislation, the Council Directive 93/42/EEC of 14 June 1993 concerning medical devices (Medical Device Directive, MDD), requires that all medical devices placed on the European market bear the CE marking. From 14 June 1998, medical devices fall under the scope of this European Medical Device Directive and there is a harmonization within the European market. Similar to this, but for another market, are the USA FDA requirements, Premarket Approval (PMA) and Premarket notification (510(k)). The same medical device, the same goal - a safe product - but different legislation and thus duplication of registration procedures. The European Commission is presently discussing a series of agreements with third countries, Australia, New Zealand, USA, Canada, Japan and Eastern European countries wishing to join the EU, concerning the mutual acceptance of inspection bodies and, ultimately, proof of conformity (for example reports on examination, certificates, licenses and marks of conformity) in connection with medical devices. Meanwhile agreements with Australia, New Zealand, USA and Canada came into force. (author)

  15. The potential of medical device industry in technological and economical context

    Directory of Open Access Journals (Sweden)

    Maresova P

    2015-10-01

    Full Text Available Petra Maresova,1 Marek Penhaker,1,2 Ali Selamat,1,3 Kamil Kuca1,41Faculty of Informatics and Management, University of Hradec Králové, Hradec Králové, Czech Republic; 2Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, Technical University of Ostrava, Poruba, Czech Republic; 3Faculty of Computing, Universiti Teknologi Malaysia, Johor Bahru, Johor, Malaysia; 4Center for Biomedical Research, University Hospital Hradec Králové, Hradec Králové, Czech RepublicAbstract: The high quality of public health improves not only healthy life expectancy, but also the productivity of labor. The most important part of the health care sector is the medical technology industry. The aim of this study is to analyze the current situation in the medical device industry in Europe, its potential strengths and weaknesses in the context of topical economic and demographic development. The contribution specifies an analysis of the economic state of the medical device industry in the context of demographic development of European Union’s macroeconomic indicators and views of experts in the field of medical device development, concerning the opportunities for entities involved in the medical device market. There is fierce competition on the European market. The innovative activity is stable and well regulated by responsible authorities. Worldwide, the medical device market is expected to grow.Keywords: technology context, medical device, Europe, expenditure, review

  16. Hydrophilic Polymer Embolism: Implications for Manufacturing, Regulation, and Postmarket Surveillance of Coated Intravascular Medical Devices.

    Science.gov (United States)

    Mehta, Rashi I; Mehta, Rupal I

    2018-03-19

    Hydrophilic polymers are ubiquitously applied as surface coatings on catheters and intravascular medical technologies. Recent clinical literature has heightened awareness on the complication of hydrophilic polymer embolism, the phenomenon wherein polymer coating layers separate from catheter and device surfaces, and may be affiliated with a range of unanticipated adverse reactions. Significant system barriers have limited and delayed reporting on this iatrogenic complication, the full effects of which remain underrecognized by healthcare providers and manufacturers of various branded devices. In 2015, the United States Food and Drug Administration acknowledged rising clinical concerns and stated that the agency would work with stakeholders to further evaluate gaps that exist in current national and international device standards for coated intravascular medical technologies. The present article reviews current knowledge on this complication as well as factors that played a role in delaying detection and dissemination of information and new knowledge once hazards and clinical risks were identified. Furthermore, organ-specific effects and adverse reaction patterns are summarized, along with implications for device manufacturing, safety assurance, and regulation. Qualitative and quantitative particulate testing are needed to optimize coated intravascular device technologies. Moreover, general enhanced processes for medical device surveillance are required for timely adverse event management and to ensure patient safety.

  17. 77 FR 4252 - Additional Spectrum for the Medical Device Radiocommunication Service

    Science.gov (United States)

    2012-01-27

    ... licensed users in these frequency bands to continue providing service. Medical Micro-Power Networks (MMNs...). Under this approach, medical devices would operate in the band on a shared, non-exclusive basis with...Radio Service rules for devices operating in the 413-457 MHz band. These definitions were for a Medical...

  18. Laser direct writing of micro- and nano-scale medical devices

    Science.gov (United States)

    Gittard, Shaun D; Narayan, Roger J

    2010-01-01

    Laser-based direct writing of materials has undergone significant development in recent years. The ability to modify a variety of materials at small length scales and using short production times provides laser direct writing with unique capabilities for fabrication of medical devices. In many laser-based rapid prototyping methods, microscale and submicroscale structuring of materials is controlled by computer-generated models. Various laser-based direct write methods, including selective laser sintering/melting, laser machining, matrix-assisted pulsed-laser evaporation direct write, stereolithography and two-photon polymerization, are described. Their use in fabrication of microstructured and nanostructured medical devices is discussed. Laser direct writing may be used for processing a wide variety of advanced medical devices, including patient-specific prostheses, drug delivery devices, biosensors, stents and tissue-engineering scaffolds. PMID:20420557

  19. Open-source hardware for medical devices.

    Science.gov (United States)

    Niezen, Gerrit; Eslambolchilar, Parisa; Thimbleby, Harold

    2016-04-01

    Open-source hardware is hardware whose design is made publicly available so anyone can study, modify, distribute, make and sell the design or the hardware based on that design. Some open-source hardware projects can potentially be used as active medical devices. The open-source approach offers a unique combination of advantages, including reducing costs and faster innovation. This article compares 10 of open-source healthcare projects in terms of how easy it is to obtain the required components and build the device.

  20. Modelling degradation of bioresorbable polymeric medical devices

    CERN Document Server

    Pan, J

    2015-01-01

    The use of bioresorbable polymers in stents, fixation devices and tissue engineering is revolutionising medicine. Both industry and academic researchers are interested in using computer modelling to replace some experiments which are costly and time consuming. This book provides readers with a comprehensive review of modelling polymers and polymeric medical devices as an alternative to practical experiments. Chapters in part one provide readers with an overview of the fundamentals of biodegradation. Part two looks at a wide range of degradation theories for bioresorbable polymers and devices.

  1. Use-related risk analysis for medical devices based on improved FMEA.

    Science.gov (United States)

    Liu, Long; Shuai, Ma; Wang, Zhu; Li, Ping

    2012-01-01

    In order to effectively analyze and control use-related risk of medical devices, quantitative methodologies must be applied. Failure Mode and Effects Analysis (FMEA) is a proactive technique for error detection and risk reduction. In this article, an improved FMEA based on Fuzzy Mathematics and Grey Relational Theory is developed to better carry out user-related risk analysis for medical devices. As an example, the analysis process using this improved FMEA method for a certain medical device (C-arm X-ray machine) is described.

  2. Home Use Devices: How to Prepare for and Handle Power Outages for Medical Devices That Require Electricity

    Science.gov (United States)

    ... to Create a Personal Emergency File My personal emergency file contains: □ Instructions for using the medical device and all device manuals. □ First aid kit □ Medical records □ Insurance cards □ Current home care doctor’s orders □ Plan of treatment □ What a family ...

  3. Extended device profiles and testing procedures for the approval process of integrated medical devices using the IEEE 11073 communication standard.

    Science.gov (United States)

    Janß, Armin; Thorn, Johannes; Schmitz, Malte; Mildner, Alexander; Dell'Anna-Pudlik, Jasmin; Leucker, Martin; Radermacher, Klaus

    2018-02-23

    Nowadays, only closed and proprietary integrated operating room systems (IORS) from big manufacturers are available on the market. Hence, the interconnection of components from third-party vendors is only possible with increased time and costs. In the context of the German Federal Ministry of Education and Research (BMBF)-funded project OR.NET (2012-2016), the open integration of medical devices from different manufacturers was addressed. An integrated operating theater based on the open communication standard IEEE 11073 shall give clinical operators the opportunity to choose medical devices independently of the manufacturer. This approach would be advantageous especially for hospital operators and small- and medium-sized enterprises (SME) of medical devices. Actual standards and concepts regarding technical feasibility and the approval process do not cope with the requirements for a modular integration of medical devices in the operating room (OR), based on an open communication standard. Therefore, innovative approval strategies and corresponding certification and test procedures, which cover actual legal and normative standards, have to be developed in order to support the future risk management and the usability engineering process of open integrated medical devices in the OR. The use of standardized device and service profiles and a three-step testing procedure, including conformity, interoperability and integration tests are described in this paper and shall support the manufacturers to integrate their medical devices without disclosing the medical devices' risk analysis and related confidential expertise or proprietary information.

  4. 76 FR 22322 - Medical Devices; Immunology and Microbiology Devices; Classification of Ovarian Adnexal Mass...

    Science.gov (United States)

    2011-04-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 866 [Docket No. FDA-2010-N-0026] Medical Devices; Immunology and Microbiology Devices; Classification of Ovarian Adnexal Mass Assessment Score Test System; Correction AGENCY: Food and Drug Administration, HHS. ACTION...

  5. Just a piece of equipment? The importance of medical device education.

    Science.gov (United States)

    Brand, Darren

    2012-12-01

    The use of medical devices is an increasingly important element of a healthcare professional's role. It is crucial that users receive regular teaching and education to ensure that they are competent in the use of devices. This is particularly relevant in the increasingly litigious society in which we live. This article focuses upon the importance of a medical device education.

  6. Evaluation of Commercial Self-Monitoring Devices for Clinical Purposes

    DEFF Research Database (Denmark)

    Leth, Soren; Hansen, John; Nielsen, Olav W

    2017-01-01

    Commercial self-monitoring devices are becoming increasingly popular, and over the last decade, the use of self-monitoring technology has spread widely in both consumer and medical markets. The purpose of this study was to evaluate five commercially available self-monitoring devices for further...... activity trackers and compared to gyroscope readings. Two trackers were also tested on nine subjects by comparing pulse readings to Holter monitoring. RESULTS: The lowest average systematic error in the walking tests was -0.2%, recorded on the Garmin Vivofit 2 at 3.5 km/h; the highest error was the Fitbit...... the current functionality and limitations of the five self-tracking devices, and point towards a need for future research in this area....

  7. New IEEE 11073 Standards for interoperable, networked Point-of-Care Medical Devices.

    Science.gov (United States)

    Kasparick, Martin; Schlichting, Stefan; Golatowski, Frank; Timmermann, Dirk

    2015-08-01

    Surgical procedures become more and more complex and the number of medical devices in an operating room (OR) increases continuously. Today's vendor-dependent solutions for integrated ORs are not able to handle this complexity. They can only form isolated solutions. Furthermore, high costs are a result of vendor-dependent approaches. Thus we present a service-oriented device communication for distributed medical systems that enables the integration and interconnection between medical devices among each other and to (medical) information systems, including plug-and-play functionality. This system will improve patient's safety by making technical complexity of a comprehensive integration manageable. It will be available as open standards that are part of the IEEE 11073 family of standards. The solution consists of a service-oriented communication technology, the so called Medical Devices Profile for Web Services (MDPWS), a Domain Information & Service Model, and a binding between the first two mechanisms. A proof of this concept has been done with demonstrators of real world OR devices.

  8. Protecting computer-based medical devices: defending against viruses and other threats.

    Science.gov (United States)

    2005-07-01

    The increasing integration of computer hardware has exposed medical devices to greater risks than ever before. More and more devices rely on commercial off-the-shelf software and operating systems, which are vulnerable to the increasing proliferation of viruses and other malicious programs that target computers. Therefore, it is necessary for hospitals to take steps such as those outlined in this article to ensure that their computer-based devices are made safe and continue to remain safe in the future. Maintaining the security of medical devices requires planning, careful execution, and a commitment of resources. A team should be created to develop a process for surveying the security status of all computerized devices in the hospital and making sure that patches and other updates are applied as needed. These patches and updates should be approved by the medical system supplier before being implemented. The team should consider using virtual local area networks to isolate susceptible devices on the hospital's network. All security measures should be carefully documented, and the documentation should be kept up-to-date. Above all, care must be taken to ensure that medical device security involves a collaborative, supportive partnership between the hospital's information technology staff and biomedical engineering personnel.

  9. 21 CFR 892.2010 - Medical image storage device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical image storage device. 892.2010 Section 892.2010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED..., and digital memory. (b) Classification. Class I (general controls). The device is exempt from the...

  10. 76 FR 16292 - Medical Devices; Immunology and Microbiology Devices; Classification of Ovarian Adnexal Mass...

    Science.gov (United States)

    2011-03-23

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 866 [Docket No. FDA-2011-N-0026] Medical Devices; Immunology and Microbiology Devices; Classification of Ovarian... of Food and Drugs, 21 CFR part 866 is amended as follows: PART 866--IMMUNOLOGY AND MICROBIOLOGY...

  11. Methodological considerations in observational comparative effectiveness research for implantable medical devices: an epidemiologic perspective.

    Science.gov (United States)

    Jalbert, Jessica J; Ritchey, Mary Elizabeth; Mi, Xiaojuan; Chen, Chih-Ying; Hammill, Bradley G; Curtis, Lesley H; Setoguchi, Soko

    2014-11-01

    Medical devices play a vital role in diagnosing, treating, and preventing diseases and are an integral part of the health-care system. Many devices, including implantable medical devices, enter the market through a regulatory pathway that was not designed to assure safety and effectiveness. Several recent studies and high-profile device recalls have demonstrated the need for well-designed, valid postmarketing studies of medical devices. Medical device epidemiology is a relatively new field compared with pharmacoepidemiology, which for decades has been developed to assess the safety and effectiveness of medications. Many methodological considerations in pharmacoepidemiology apply to medical device epidemiology. Fundamental differences in mechanisms of action and use and in how exposure data are captured mean that comparative effectiveness studies of medical devices often necessitate additional and different considerations. In this paper, we discuss some of the most salient issues encountered in conducting comparative effectiveness research on implantable devices. We discuss special methodological considerations regarding the use of data sources, exposure and outcome definitions, timing of exposure, and sources of bias. © The Author 2014. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  12. [Study on the reform and improvement of the medical device registration system in China].

    Science.gov (United States)

    Wang, Lanming

    2012-11-01

    Based on the theories of the Government Regulation and Administrative Licensure, aiming at the current situations of medical device registration system in China, some policy suggestions for future reform and improvement were provided as follows. (1) change the concepts of medical device registration administration. (2) perfect the regulations of medical device registration administration. (3) reform the medical device review organizational system. (4) Optimize the procedure of review and approval. (5) set up and maintain a professional team of review and approval staff. (6) reinforce the post-marketing supervision of medical devices. (7) foster and bring into play of the role of non-government organizations.

  13. 75 FR 70112 - Medical Devices; General and Plastic Surgery Devices; Classification of Non-Powered Suction...

    Science.gov (United States)

    2010-11-17

    .... FDA-2010-N-0513] Medical Devices; General and Plastic Surgery Devices; Classification of Non-Powered... risks. Adverse tissue reaction Material degradation Improper function of suction apparatus (e.g., reflux.... Material degradation Section 8. Stability and Shelf Life. [[Page 70113

  14. Campaign to gather medical devices containing radium: results

    International Nuclear Information System (INIS)

    Pierre, J.P.; Vidal, J.P.; Martin, J.C.; Pasquier, J.L.

    2002-01-01

    Campaign to gather medical devices containing radium: results. On December 1, 1999, at the request of the French Health Ministry, OPRI and ANDRA launched a campaign to gather medical devices containing radium, formerly used in brachytherapy. This campaign addressed a public health issue because of the risks actually involved in a careless handling of these objects. Moreover the growing number of reported scattered radium medical devices in the last few years reinforced the necessity of the campaign. The gathering was initiated by a call of the owners (hospitals, caring centers, retired doctors or their heirs) to a toll free number. OPRI or ANDRA then appreciated the situation urgency. Priority was given to private people because most of them did not have suitable storage facilities. OPRI teams operated according a strict protocol guaranteeing their own safety, proper procedures and compliance with transport regulations for radioactive materials. 517 objects amounting to an activity of 1.32 x 10 11 Bq have been gathered in 90 operations. Properly packaged they were transported to and safely stored at the CEA Saclay site before their permanent storage in the ANDRA facilities. (author)

  15. Drugs and Medical Devices: Adverse Events and the Impact on Women's Health.

    Science.gov (United States)

    Carey, Jennifer L; Nader, Nathalie; Chai, Peter R; Carreiro, Stephanie; Griswold, Matthew K; Boyle, Katherine L

    2017-01-01

    A large number of medications and medical devices removed from the market by the US Food and Drug Administration over the past 4 decades specifically posed greater health risks to women. This article reviews the historical background of sex and gender in clinical research policy and describes several approved drugs and devices targeted for use in women that have caused major morbidity and mortality. The intended population for the medications and devices, population affected, approval process, and the basic and legal actions taken against the medication/drug company are also discussed. It is recognized that women are still at risk for harm from unsafe medications and devices, and continued improvements in legislation that promotes inclusion of sex and gender into the design and analysis of research will improve safety for both men and women. Copyright © 2017 Elsevier HS Journals, Inc. All rights reserved.

  16. Development and examination of a rubric for evaluating point-of-care medical applications for mobile devices.

    Science.gov (United States)

    Butcher, Robyn; MacKinnon, Martin; Gadd, Kathleen; LeBlanc-Duchin, Denise

    2015-01-01

    The rapid development and updates of mobile medical resource applications (apps) highlight the need for an evaluation tool to assess the content of these resources. The purpose of the study was to develop and test a new evaluation rubric for medical resource apps. The evaluation rubric was designed using existing literature and through a collaborative effort between a hospital and an academic librarian. Testing found scores ranging from 23% to 88% for the apps. The evaluation rubric proved able to distinguish levels of quality within each content component of the apps, demonstrating potential for standardization of medical resource app evaluations.

  17. 76 FR 71982 - Advancing Regulatory Science for Highly Multiplexed Microbiology/Medical Countermeasure Devices...

    Science.gov (United States)

    2011-11-21

    ... Multiplexed Microbiology Devices: Their clinical application and public health/clinical needs; inclusion of...] Advancing Regulatory Science for Highly Multiplexed Microbiology/ Medical Countermeasure Devices; Public... Multiplexed Microbiology/ Medical Countermeasure Devices'' that published in the Federal Register of August 8...

  18. Adherence to hydroxyurea medication by children with sickle cell disease (SCD) using an electronic device: a feasibility study.

    Science.gov (United States)

    Inoue, Susumu; Kodjebacheva, Gergana; Scherrer, Tammy; Rice, Gary; Grigorian, Matthew; Blankenship, Jeremy; Onwuzurike, Nkechi

    2016-08-01

    Adherence to hydroxyurea (HU) is a significant modifying factor in sickle cell vaso-occlusive pain. We conducted a study using an electronic medication container-monitor-reminder device (GlowCap™) to track adherence and determine whether use of this device affected rates of HU adherence. Subjects were regular attendees to our clinic. They were given a 37-item questionnaire and were asked to use a GlowCap containing HU. When the device cap is opened, it makes a remote "medication taken" record. The device also provides usage reminder in the form of lights and alarm sounds if the cap opening is delayed. Nineteen subjects participated in the survey, and 17 in the intervention phase. Of the 17, 12 had reliable adherence data. Seventeen caregivers of patients and two patients completed the survey. Two most common barriers to adherence identified were lack of reminders and absence of medicine home delivery. The intervention component of this study, which used both the electronic (GlowCap) method and medication possession ratio showed that the median adherence rate for the 12 patients evaluated was 85 %. The GlowCap device accurately kept a record of adherence rates. This device may be an effective tool for increasing HU medication adherence.

  19. 77 FR 6028 - Taxable Medical Devices

    Science.gov (United States)

    2012-02-07

    ... sold as part of an x-ray system. Commentators also requested information on the tax treatment of..., mitigation, treatment, or prevention of disease; or intended to affect the structure or any function of the... subject to an IDE is not a ``taxable medical device'' under the proposed regulations. VI. Dental...

  20. 78 FR 33849 - Battery-Powered Medical Devices Workshop: Challenges and Opportunities; Public Workshop; Request...

    Science.gov (United States)

    2013-06-05

    ... after the public workshop on the Internet at http://www.fda.gov/MedicalDevices/NewsEvents/Workshops..., compact, and mobile, the number of battery-powered medical devices will continue to increase. While many...] Battery-Powered Medical Devices Workshop: Challenges and Opportunities; Public Workshop; Request for...

  1. 75 FR 68972 - Medical Devices; General and Plastic Surgery Devices; Classification of Tissue Adhesive With...

    Science.gov (United States)

    2010-11-10

    .... FDA-2010-N-0512] Medical Devices; General and Plastic Surgery Devices; Classification of Tissue... running to unintended areas, etc. B. Wound dehiscence C. Adverse tissue reaction and chemical burns D..., Clinical Studies, Labeling. Adverse tissue reaction and chemical Biocompatibility Animal burns. Testing...

  2. 77 FR 32644 - Medical Devices; Exemption From Premarket Notification: Wheelchair Elevator

    Science.gov (United States)

    2012-06-01

    ...] Medical Devices; Exemption From Premarket Notification: Wheelchair Elevator AGENCY: Food and Drug... elevator devices commonly known as inclined platform lifts and vertical platform lifts. These devices are... behalf of Bruno Independent Living Aids, Inc., for wheelchair elevator devices (commonly known as...

  3. Views of patients and professionals about electronic multicompartment medication devices: a qualitative study.

    Science.gov (United States)

    Hall, Jill; Bond, Christine; Kinnear, Moira; McKinstry, Brian

    2016-10-17

    To explore the perceived acceptability, advantages and disadvantages of electronic multicompartment medication devices. Qualitative study using 8 focus groups and 10 individual semistructured interviews. Recordings were transcribed and analysed thematically. Strategies were employed to ensure the findings were credible and trustworthy. Community pharmacists (n=11), general practitioners (n=9), community nurses (n=12) and social care managers (n=8) were recruited from the National Health Service (NHS) and local authority services. Patients (n=15) who were current conventional or electronic multicompartment medication device users or had medication adherence problems were recruited from community pharmacies. 3 informal carers participated. Electronic multicompartment medication devices which prompt the patient to take medication may be beneficial for selected individuals, particularly those with cognitive impairment, but who are not seriously impaired, provided they have a good level of dexterity. They may also assist individuals where it is important that medication is taken at fixed time intervals. These are likely to be people who are being supported to live alone. No single device suited everybody; smaller/lighter devices were preferred but their usefulness was limited by the small number/size of storage compartments. Removing medications was often challenging. Transportability was an important factor for patients and carers. A carer's alert if medication is not taken was problematic with multiple barriers to implementation and no consensus as to who should receive the alert. There was a lack of enthusiasm among professionals, particularly among pharmacists, due to concerns about responsibility and funding for devices as well as ensuring devices met regulatory standards for storage and labelling. This study provides indicators of which patients might benefit from an electronic multicompartment medication device as well as the kinds of features to consider when

  4. Left to their own devices: medical learners' use of mobile technologies.

    Science.gov (United States)

    Ellaway, Rachel H; Fink, Patricia; Graves, Lisa; Campbell, Alanna

    2014-02-01

    Although many medical learners and teachers are using mobile technologies within medical education, there has been little evidence presented describing how they use mobile devices across a whole curriculum. The Northern Ontario School of Medicine (NOSM) introduced a new mobile device program in 2010. Incoming undergraduate medical learners received a laptop and an iPad and learners entering year three of the four-year program received a laptop and an iPhone. A survey was sent to all learners to gather information on their use of and attitudes toward these devices. A combination of quantitative and qualitative methods was used to analyze the data and to generate a series of themes that synthesized student behaviors, perceptions and attitudes. Context and learner autonomy were found to be important factors with learners using multiple devices for different purposes and adopting strategic approaches to learning using these devices. The expectation that school-issued devices would be regularly and enthusiastically used to replace more traditional study media was not reflected in practice. Learners' approaches to using mobile devices are heterogeneous as is the extent to which they use them. Learners adapt their use of mobile devices to the learning cultures and contexts they find themselves in.

  5. How do health service professionals consider human factors when purchasing interactive medical devices? A qualitative interview study.

    Science.gov (United States)

    Vincent, Christopher James; Blandford, Ann

    2017-03-01

    We present findings of a UK study into how those involved in purchasing interactive medical devices go about evaluating usability, the challenges that arise, and opportunities for improvement. The study focused on procurement of infusion devices because these are used by various professionals across healthcare. A semi-structured interview study was carried out involving a range of stakeholders (20 in total) involved in or impacted by medical device procurement. Data was analysed using thematic analysis, a qualitative method designed to support the identification, analysis and reporting of patterns. In principle, health service purchasing was found to accommodate consideration of equipment usability. In practice, the evaluation process was driven primarily by engineering standards; assessment of local needs did not accommodate substantive assessment of usability; and choice was limited by the availability of equipment on the marketplace. We discuss ways in which purchasing could be improved through techniques that account for social circumstances. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Possibilities of radiation sterilization for re-usage of medical devices in the medical management

    International Nuclear Information System (INIS)

    Tabei, Masae; Kudo, Hisaaki; Katsumura, Yosuke

    2004-01-01

    The rule for re-usage of medical single-use devices was established in US in 2000 based on the concept of Managed Care (total management of medicare on cost, quality and patients' satisfaction) and 20-30% of those devices are re-used at present. The re-usage is conducted in not only US but also Canada, Denmark, UK, India, China etc. Standing on the viewpoint, this paper described and discussed the possibility of re-usage of the single-use devices now prohibited in Japan, possible re-sterilization, possible re-usage of hollow fiber-type hemodialyzer following γ-ray sterilization with consideration for D-values against bacteria and viruses, cost estimation of electron beam sterilization for re-usage, and radiation sterilization of waste water and plastic materials. Radiation sterilization for re-usage of medical devices was concluded possible if their materials and records for their usage processes are proper, and should be conducted in a large scale after sufficient examinations by industries/government/academia. (N.I.)

  7. Third-year medical students' knowledge of privacy and security issues concerning mobile devices.

    Science.gov (United States)

    Whipple, Elizabeth C; Allgood, Kacy L; Larue, Elizabeth M

    2012-01-01

    The use of mobile devices are ubiquitous in medical-care professional settings, but information on privacy and security concerns of mobile devices for medical students is scarce. To gain baseline information about third-year medical students' mobile device use and knowledge of privacy and security issues concerning mobile devices. We surveyed 67 third-year medical students at a Midwestern university on their use of mobile devices and knowledge of how to protect information available through mobile devices. Students were also presented with clinical scenarios to rate their level of concern in regards to privacy and security of information. The most used features of mobile devices were: voice-to-voice (100%), text messaging (SMS) (94%), Internet (76.9%), and email (69.3%). For locking of one's personal mobile phone, 54.1% never physically lock their phone, and 58% never electronically lock their personal PDA. Scenarios considering definitely privacy concerns include emailing patient information intact (66.7%), and posting de-identified information on YouTube (45.2%) or Facebook (42.2%). As the ease of sharing data increases with the use of mobile devices, students need more education and training on possible privacy and security risks posed with mobile devices.

  8. Low power signal processing electronics for wearable medical devices.

    Science.gov (United States)

    Casson, Alexander J; Rodriguez-Villegas, Esther

    2010-01-01

    Custom designed microchips, known as Application Specific Integrated Circuits (ASICs), offer the lowest possible power consumption electronics. However, this comes at the cost of a longer, more complex and more costly design process compared to one using generic, off-the-shelf components. Nevertheless, their use is essential in future truly wearable medical devices that must operate for long periods of time from physically small, energy limited batteries. This presentation will demonstrate the state-of-the-art in ASIC technology for providing online signal processing for use in these wearable medical devices.

  9. Stakeholder challenges in purchasing medical devices for patient safety.

    Science.gov (United States)

    Hinrichs, Saba; Dickerson, Terry; Clarkson, John

    2013-03-01

    This study identifies the stakeholders who have a role in medical device purchasing within the wider system of health-care delivery and reports on their particular challenges to promote patient safety during purchasing decisions. Data was collected through observational work, participatory workshops, and semi-structured qualitative interviews, which were analyzed and coded. The study takes a systems-based and engineering design approach to the study. Five hospitals took part in this study, and the participants included maintenance, training, clinical end-users, finance, and risk departments. The main stakeholders for purchasing were identified to be staff from clinical engineering (Maintenance), device users (Clinical), device trainers (Training), and clinical governance for analyzing incidents involving devices (Risk). These stakeholders display varied characteristics in terms of interpretation of their own roles, competencies for selecting devices, awareness and use of resources for purchasing devices, and attitudes toward the purchasing process. The role of "clinical engineering" is seen by these stakeholders to be critical in mediating between training, technical, and financial stakeholders but not always recognized in practice. The findings show that many device purchasing decisions are tackled in isolation, which is not optimal for decisions requiring knowledge that is currently distributed among different people within different departments. The challenges expressed relate to the wider system of care and equipment management, calling for a more systemic view of purchasing for medical devices.

  10. Evaluation device of diagnostic X-ray beam

    International Nuclear Information System (INIS)

    Pela, Carlos Alberto; Paula, Eldereis de; Bruco, Jose Luiz; Ghilardi Netto, Thomaz

    1996-01-01

    A device developed to determine the physical parameters useful to the evaluation of both dental and medical X-ray equipment is presented. Nine detectors connected each one to a signal amplifier are used. The amplifiers output has being connected to an analog to digital interface plugged in a PC-AT microcomputer. The X-ray pass through filters before reaching the detectors. The data collected by microcomputer are used to calculate the kVp and other factors as total tube filtration, waveform, half-value layer, exposure rate and exposure time

  11. Research on dose setting for radiation sterilization of medical device

    International Nuclear Information System (INIS)

    Zhang Tongcheng; Liu Qingfang; Zhong Hongliang; Mi Zhisu; Wang Chunlei; Jiang Jianping

    2002-01-01

    Objective: To establish the radiation sterilization dose for medical devices using data of bioburden on the medical device. Methods: Firstly determination of recovery ratio and correction coefficient of the microbiological test method was used according to ISO11737 standard, then determination of bioburden on the products, finally the dose setting was completed based on the Method 1 in ISO11137 standard. Results: Fifteen kinds of medical devices were tested. Bioburden range was from 8.6-97271.2 CFU/device, recovery ration range 54.6%-100%, correction co-efficiency range 1.00-1.83, D 10 distribution from 1.40 to 2.82 kGy, verification dose (dose at SAL = 10 -2 ) range 5.1-17.6 kGy and sterilization dose (dose at SAL 10 -6 ) range 17.5-32.5 kGy. Conclusion: One hundred samples of each kind of product were exposed to the pre-determined verification dose and then the sterility test was performed. Each sterility test showed positive number was not greater than two. This indicated that the sterilization dose established for each kind of product was statistically acceptable

  12. 77 FR 32642 - Medical Devices; Exemption From Premarket Notification: Powered Patient Transport

    Science.gov (United States)

    2012-06-01

    ...] Medical Devices; Exemption From Premarket Notification: Powered Patient Transport AGENCY: Food and Drug... received a petition requesting exemption from the premarket notification requirements for powered patient... necessary to provide a reasonable assurance of safety and effectiveness. Under the Medical Device Amendments...

  13. 76 FR 14414 - Microbiology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2011-03-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES [Docket No. FDA-2011-N-0002] Microbiology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and Drug Administration, HHS... and Drug Administration (FDA). The meeting will be open to the public. Name of Committee: Microbiology...

  14. Medical Device Plug-and-Play Interoperability Standards and Technology Leadership

    Science.gov (United States)

    2010-10-01

    American Telemedicine Association), we demonstrated how continuous monitoring of the patient’s SpO2 and respiratory rate could detect the onset of...designed to monitor sepsis infection sounded its alarm continually, day and night. The device was built with an innovative algorithm to detect sepsis, but...transport Figure 3. This medical device has misread its sensors and inserted false data into patient’s permanent medical record. SPECIal FEaTuRE October

  15. Relative risk analysis in regulating the use of radiation-emitting medical devices. A preliminary application

    Energy Technology Data Exchange (ETDEWEB)

    Jones, E.D.; Banks, W.W.; Altenbach, T.J.; Fischer, L.E. [Lawrence Livermore National Lab., CA (United States)

    1995-09-01

    This report describes a preliminary application of an analysis approach for assessing relative risks in the use of radiation- emitting medical devices. Results are presented on human-initiated actions and failure modes that are most likely to occur in the use of the Gamma Knife, a gamma irradiation therapy device. This effort represents an initial step in a US Nuclear Regulatory Commission (NRC) plan to evaluate the potential role of risk analysis in regulating the use of nuclear medical devices. For this preliminary application of risk assessment, the focus was to develop a basic process using existing techniques for identifying the most likely risk contributors and their relative importance. The approach taken developed relative risk rankings and profiles that incorporated the type and quality of data available and could present results in an easily understood form. This work was performed by the Lawrence Livermore National Laboratory for the NRC.

  16. Relative risk analysis in regulating the use of radiation-emitting medical devices. A preliminary application

    International Nuclear Information System (INIS)

    Jones, E.D.; Banks, W.W.; Altenbach, T.J.; Fischer, L.E.

    1995-09-01

    This report describes a preliminary application of an analysis approach for assessing relative risks in the use of radiation- emitting medical devices. Results are presented on human-initiated actions and failure modes that are most likely to occur in the use of the Gamma Knife, a gamma irradiation therapy device. This effort represents an initial step in a US Nuclear Regulatory Commission (NRC) plan to evaluate the potential role of risk analysis in regulating the use of nuclear medical devices. For this preliminary application of risk assessment, the focus was to develop a basic process using existing techniques for identifying the most likely risk contributors and their relative importance. The approach taken developed relative risk rankings and profiles that incorporated the type and quality of data available and could present results in an easily understood form. This work was performed by the Lawrence Livermore National Laboratory for the NRC

  17. 21 CFR 801.16 - Medical devices; Spanish-language version of certain required statements.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical devices; Spanish-language version of....16 Medical devices; Spanish-language version of certain required statements. If devices restricted to prescription use only are labeled solely in Spanish for distribution in the Commonwealth of Puerto Rico where...

  18. Review of "Handbook of Human Factors in Medical Device Design", edited by Matthew B. Weinger, Michael E. Wiklund and Daryle J. Gardner-Bonneau, Assistant Editor Loir M. Kelly

    Directory of Open Access Journals (Sweden)

    Gaev Jonathan A

    2011-06-01

    Full Text Available Abstract Human factors is the study of the relationship between people and devices or systems. The goal of considering human factors in the design of medical devices is to create devices that take into consideration the way people use technology and process information to create a man-machine interface that leads to the best possible performance. This text describes the significant aspects of human factors issues related to medical device design. It is well written and is useful for medical device designers and for others who use or evaluate medical equipment.

  19. Software-Related Recalls of Health Information Technology and Other Medical Devices: Implications for FDA Regulation of Digital Health.

    Science.gov (United States)

    Ronquillo, Jay G; Zuckerman, Diana M

    2017-09-01

    Policy Points: Medical software has become an increasingly critical component of health care, yet the regulation of these devices is inconsistent and controversial. No studies of medical devices and software assess the impact on patient safety of the FDA's current regulatory safeguards and new legislative changes to those standards. Our analysis quantifies the impact of software problems in regulated medical devices and indicates that current regulations are necessary but not sufficient for ensuring patient safety by identifying and eliminating dangerous defects in software currently on the market. New legislative changes will further deregulate health IT, reducing safeguards that facilitate the reporting and timely recall of flawed medical software that could harm patients. Medical software has become an increasingly critical component of health care, yet the regulatory landscape for digital health is inconsistent and controversial. To understand which policies might best protect patients, we examined the impact of the US Food and Drug Administration's (FDA's) regulatory safeguards on software-related technologies in recent years and the implications for newly passed legislative changes in regulatory policy. Using FDA databases, we identified all medical devices that were recalled from 2011 through 2015 primarily because of software defects. We counted all software-related recalls for each FDA risk category and evaluated each high-risk and moderate-risk recall of electronic medical records to determine the manufacturer, device classification, submission type, number of units, and product details. A total of 627 software devices (1.4 million units) were subject to recalls, with 12 of these devices (190,596 units) subject to the highest-risk recalls. Eleven of the devices recalled as high risk had entered the market through the FDA review process that does not require evidence of safety or effectiveness, and one device was completely exempt from regulatory review

  20. Health Care: Reprocessed Medical Single-Use Devices in DoD

    National Research Council Canada - National Science Library

    2002-01-01

    ... for decontamination and resterilization. The emergence of new materials and sterilization methods, and the increasing costs of health care, resulted in the development of medical single-use devices and the practice of reprocessing the devices...

  1. Management information system of medical equipment using mobile devices

    Science.gov (United States)

    Núñez, C.; Castro, D.

    2011-09-01

    The large numbers of technologies currently incorporated into mobile devices transform them into excellent tools for capture and to manage the information, because of the increasing computing power and storage that allow to add many miscellaneous applications. In order to obtain benefits of these technologies, in the biomedical engineering field, it was developed a mobile information system for medical equipment management. The central platform for the system it's a mobile phone, which by a connection with a web server, it's capable to send and receive information relative to any medical equipment. Decoding a type of barcodes, known as QR-Codes, the management process is simplified and improved. These barcodes identified the medical equipments in a database, when these codes are photographed and decoded with the mobile device, you can access to relevant information about the medical equipment in question. This Project in it's actual state is a basic support tool for the maintenance of medical equipment. It is also a modern alternative, competitive and economic in the actual market.

  2. Evaluating imaging devices

    International Nuclear Information System (INIS)

    Rollo, F.D.

    1977-01-01

    The performance of any imaging device depends on two principal factors inherent to the device, namely, plane sensitivity and spatial resolution. These factors may be defined as follows: plane sensitivity is the counts per second recorded by the imaging device for each disintegration per second per square centimeter occurring within a plane sheet of radioactivity. Spatial resolution may be defined as the fidelity with which the imaging device reproduces the activity distribution of an object in the image plane. In all imaging devices, a trade-off exists between these two parameters; that is, as sensitivity improves, spatial resolution is degraded, and vice versa. Therefore, to fully evaluate an imaging system a technique should be selected that measures both parameters and reflects the trade-off between the two. In addition, the method should approximate the clinical problem, namely, the detection of a focal lesion within an activity distribution. Several methods have been described to evaluate nuclear imaging devices. The more common techniques include the use of organ phantoms, bar phantoms, line-spread functions, modulation transfer functions, contrast efficiency functions, and performance index functions. Each of these techniques is briefly described in this chapter, and their advantages and disadvantages are discussed. In addition, a phantom that can be used to simply and completely measure overall imaging system performance is described

  3. 31 CFR 595.513 - In-kind donations of medicine, medical devices, and medical services.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false In-kind donations of medicine...-kind donations of medicine, medical devices, and medical services. (a) Effective July 6, 2006, nongovernmental organizations that are U.S. persons are authorized to provide in-kind donations of medicine...

  4. 75 FR 1395 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of...

    Science.gov (United States)

    2010-01-11

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2009-N-0606] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of Notice...) is announcing an amendment to the notice of a meeting of the General and Plastic Surgery Devices...

  5. Towards automated assistance for operating home medical devices.

    Science.gov (United States)

    Gao, Zan; Detyniecki, Marcin; Chen, Ming-Yu; Wu, Wen; Hauptmann, Alexander G; Wactlar, Howard D

    2010-01-01

    To detect errors when subjects operate a home medical device, we observe them with multiple cameras. We then perform action recognition with a robust approach to recognize action information based on explicitly encoding motion information. This algorithm detects interest points and encodes not only their local appearance but also explicitly models local motion. Our goal is to recognize individual human actions in the operations of a home medical device to see if the patient has correctly performed the required actions in the prescribed sequence. Using a specific infusion pump as a test case, requiring 22 operation steps from 6 action classes, our best classifier selects high likelihood action estimates from 4 available cameras, to obtain an average class recognition rate of 69%.

  6. Recent advances in medical device triage technologies for chemical, biological, radiological, and nuclear events.

    Science.gov (United States)

    Lansdowne, Krystal; Scully, Christopher G; Galeotti, Loriano; Schwartz, Suzanne; Marcozzi, David; Strauss, David G

    2015-06-01

    In 2010, the US Food and Drug Administration (Silver Spring, Maryland USA) created the Medical Countermeasures Initiative with the mission of development and promoting medical countermeasures that would be needed to protect the nation from identified, high-priority chemical, biological, radiological, or nuclear (CBRN) threats and emerging infectious diseases. The aim of this review was to promote regulatory science research of medical devices and to analyze how the devices can be employed in different CBRN scenarios. Triage in CBRN scenarios presents unique challenges for first responders because the effects of CBRN agents and the clinical presentations of casualties at each triage stage can vary. The uniqueness of a CBRN event can render standard patient monitoring medical device and conventional triage algorithms ineffective. Despite the challenges, there have been recent advances in CBRN triage technology that include: novel technologies; mobile medical applications ("medical apps") for CBRN disasters; electronic triage tags, such as eTriage; diagnostic field devices, such as the Joint Biological Agent Identification System; and decision support systems, such as the Chemical Hazards Emergency Medical Management Intelligent Syndromes Tool (CHEMM-IST). Further research and medical device validation can help to advance prehospital triage technology for CBRN events.

  7. 31 CFR 594.515 - In-kind donations of medicine, medical devices, and medical services.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false In-kind donations of medicine....515 In-kind donations of medicine, medical devices, and medical services. (a) Effective July 6, 2006, nongovernmental organizations that are U.S. persons are authorized to provide in-kind donations of medicine...

  8. 31 CFR 597.511 - In-kind donations of medicine, medical devices, and medical services.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false In-kind donations of medicine... Licensing Policy § 597.511 In-kind donations of medicine, medical devices, and medical services. (a... incident to the provision by nongovernmental organizations that are U.S. persons of in-kind donations of...

  9. ANSTO and CSIRO: supporting the medical devices and sensors industry in Australia

    International Nuclear Information System (INIS)

    Triani, Gerry; Doe, Simon

    2005-01-01

    The Australian Nuclear Science and Technology Organisation (ANSTO) and the Commonwealth Scientific and Industrial Research Organisation (CSIRO) have provided support to the Medical Devices and Sensors Industry in Australia for many years. In particular the Institute of Materials and Engineering Science at ANSTO and CSIRO Manufacturing and Infrastructure Technology have worked independently and jointly on a number of projects to provide technical services and support to small to medium sized companies. A recent venture to capture their capabilities in the WTIA's Medical Devices and Sensors Industry Sectoral Project, part of the WTIA National Diffusion Networks Project, has produced substantial technical and financial gains for its participants. The aim of this article is to highlight the infrastructure and capabilities that ANSTO and CSIRO can provide to component manufacturers and industry clusters that offer a range of manufacturing processes needed for medical devices and sensors. Several case studies illustrate how ANSTO and CSIRO have provided support to the medical devices industry

  10. Evaluation of stability of polymeric insulation materials in radiation fields and development of radiation stable PVC and polypropylene for medical devices

    International Nuclear Information System (INIS)

    Gonzalez, M.E.; Docters, A.S.

    1999-01-01

    Radiation stability of polypropylene and polyvinylchloride medical products of local origin was evaluated, establishing their functionality by appropriate methods. A device for a mechanical test of syringes and another device for puncture testing of plastic films were constructed and tested. Shelf-life anticipation of irradiated products was examined by treating to high doses and in other cases by storing irradiated products at high temperatures. In both cases negative results would anticipate no functionality for real time aged products. Radiation stability improvement was tried by incorporating light protectors and antioxidants into polypropylene homopolymer. A composition with added light protector was obtained that did not discolor and that kept mechanical stability during aging. Polyvinylchloride tubing was examined and found stable in comparison with imported materials. A non-discoloring product could not be obtained. Evaluation of local commercial polyvinylchloride insulations of wires similar to the wires used in the conveyor system of the Irradiation Facility of Ezeiza Atomic Center suggested that the limit of 50 % reduction in elongation to break in relation to control samples as an indication of failure is too conservative, because this limit was reached much earlier than the actual period of use of installed wires. (author)

  11. Sterilization and reprocessing of materials and medical devices--reusability.

    Science.gov (United States)

    Jayabalan, M

    1995-07-01

    Problems associated with reprocessing of disposable medical devices such as hemodialysers with resterilization for reuse and changes in material properties with resterilization of polymeric (PVC, polypropylene, polyester, polycarbonate) materials intended for development of disposable devices are reviewed. Reprocessing of hospital supplies, polystyrene microtiter plate and angiographic catheter for reuse is also discussed.

  12. Home Healthcare Medical Devices: Infusion Therapy - Getting the Most Out of Your Pump

    Science.gov (United States)

    ... Medical Procedures Home Health and Consumer Devices Brochure - Home Healthcare Medical Devices: Infusion Therapy - Getting the Most ... if needed. What is the role of your home healthcare provider and supplier in your infusion therapy? ...

  13. 76 FR 42713 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of...

    Science.gov (United States)

    2011-07-19

    ...] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of Notice... announcing an amendment to the notice of meeting of the General and Plastic Surgery Devices Panel of the... INFORMATION: In the Federal Register of July 7, 2011, FDA announced that a meeting of the General and Plastic...

  14. OR.NET: a service-oriented architecture for safe and dynamic medical device interoperability.

    Science.gov (United States)

    Kasparick, Martin; Schmitz, Malte; Andersen, Björn; Rockstroh, Max; Franke, Stefan; Schlichting, Stefan; Golatowski, Frank; Timmermann, Dirk

    2018-02-23

    Modern surgical departments are characterized by a high degree of automation supporting complex procedures. It recently became apparent that integrated operating rooms can improve the quality of care, simplify clinical workflows, and mitigate equipment-related incidents and human errors. Particularly using computer assistance based on data from integrated surgical devices is a promising opportunity. However, the lack of manufacturer-independent interoperability often prevents the deployment of collaborative assistive systems. The German flagship project OR.NET has therefore developed, implemented, validated, and standardized concepts for open medical device interoperability. This paper describes the universal OR.NET interoperability concept enabling a safe and dynamic manufacturer-independent interconnection of point-of-care (PoC) medical devices in the operating room and the whole clinic. It is based on a protocol specifically addressing the requirements of device-to-device communication, yet also provides solutions for connecting the clinical information technology (IT) infrastructure. We present the concept of a service-oriented medical device architecture (SOMDA) as well as an introduction to the technical specification implementing the SOMDA paradigm, currently being standardized within the IEEE 11073 service-oriented device connectivity (SDC) series. In addition, the Session concept is introduced as a key enabler for safe device interconnection in highly dynamic ensembles of networked medical devices; and finally, some security aspects of a SOMDA are discussed.

  15. El Centro de Cardioestimuladores del Uruguay. CCC Medical Devices

    Directory of Open Access Journals (Sweden)

    Pablo Darscht

    2011-05-01

    Full Text Available Estudio de caso del Centro de Cardioestimuladores del Uruguay - CCC Medical Devices preparado a solicitud de Ingenio en el marco del proyecto financiado por la Iniciativa para Incubadoras de InfoDev - Grupo Banco Mundial. Este estudio detalla los pasos seguidos por una empresa nacional con un fuerte factor de innovación y los cambios producidos en el entorno de los negocios de la empresa. El comienzo de una pequeña empresa de marcapasos que tras pasar por diferentes etapas hoy gana mercados en el área de ingeniería para dispositivos médicos para diferentes empresas de investigación biomédica a nivel internacional.AbstractCase study of the Centro de Cardioestimuladores del Uruguay - CCC Medical Devices prepared on behalf of Ingenio within the project financed by de Incubator Initiative of InfoDev-World Bank Group. This study refers to the steps followed by a highly innovative local company and to the changes in its business environment. The start up of a small pacemakers company that after going through different stages is presently increasing its market share in the area of engineering of medical devices for biomedic research companies worldwide.

  16. Current status of the regulation for medical devices

    OpenAIRE

    Shah Anuja; Goyal R

    2008-01-01

    In the light of escalating use of medical devices, stringent regulatory standards are required to ensure that the devices are safe, well studied and have least adverse reactions. Recently introduced guidelines and the amendment in the law will provide adequate guidance for both the manufacturers and competent authorities to manage cases efficiently and appropriately. India has emerged as one of the leaders in pharmaceutical industry. Like many other amendments in Drugs and Cosmetics Act that ...

  17. Post market surveillance in the german medical device sector - current state and future perspectives.

    Science.gov (United States)

    Zippel, Claus; Bohnet-Joschko, Sabine

    2017-08-01

    Medical devices play a central role in the diagnosis and treatment of diseases but also bring the potential for adverse events, hazards or malfunction with serious consequences for patients and users. Medical device manufacturers are therefore required by law to monitor the performance of medical devices that have been approved by the competent authorities (post market surveillance). Conducting a nationwide online-survey in the German medical device sector in Q2/2014 in order to explore the current status of the use of post market instruments we obtained a total of 118 complete data sets, for a return rate of 36%. The survey included manufacturers of different sizes, producing medical devices of all risk classes. The post market instruments most frequently reported covered the fields of production monitoring and quality management as well as literature observation, regulatory vigilance systems, customer knowledge management and market observation while Post Market Clinical Follow-up and health services research were being used less for product monitoring. We found significant differences between the different risk classes of medical devices produced and the intensity of use of post market instruments. Differences between company size and the intensity of instruments used were hardly detected. Results may well contribute to the development of device monitoring which is a crucial element of the policy and regulatory system to identify device-related safety issues. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Image Quality Characteristics of Handheld Display Devices for Medical Imaging

    Science.gov (United States)

    Yamazaki, Asumi; Liu, Peter; Cheng, Wei-Chung; Badano, Aldo

    2013-01-01

    Handheld devices such as mobile phones and tablet computers have become widespread with thousands of available software applications. Recently, handhelds are being proposed as part of medical imaging solutions, especially in emergency medicine, where immediate consultation is required. However, handheld devices differ significantly from medical workstation displays in terms of display characteristics. Moreover, the characteristics vary significantly among device types. We investigate the image quality characteristics of various handheld devices with respect to luminance response, spatial resolution, spatial noise, and reflectance. We show that the luminance characteristics of the handheld displays are different from those of workstation displays complying with grayscale standard target response suggesting that luminance calibration might be needed. Our results also demonstrate that the spatial characteristics of handhelds can surpass those of medical workstation displays particularly for recent generation devices. While a 5 mega-pixel monochrome workstation display has horizontal and vertical modulation transfer factors of 0.52 and 0.47 at the Nyquist frequency, the handheld displays released after 2011 can have values higher than 0.63 at the respective Nyquist frequencies. The noise power spectra for workstation displays are higher than 1.2×10−5 mm2 at 1 mm−1, while handheld displays have values lower than 3.7×10−6 mm2. Reflectance measurements on some of the handheld displays are consistent with measurements for workstation displays with, in some cases, low specular and diffuse reflectance coefficients. The variability of the characterization results among devices due to the different technological features indicates that image quality varies greatly among handheld display devices. PMID:24236113

  19. "Joint Workshop on High Confidence Medical Devices, Software, and Systems (HCMDSS) and Medical Device Plug-and-Play (MD PnP) Interoperability"

    National Research Council Canada - National Science Library

    Goldman, Julian M

    2008-01-01

    Partial support was requested from TATRC, with joint funding from NSF, for a joint workshop to bring together the synergistic efforts and communities of the High Confidence Medical Devices, Software, and Systems (HCMDSS...

  20. Value driven innovation in medical device design: a process for balancing stakeholder voices.

    Science.gov (United States)

    de Ana, F J; Umstead, K A; Phillips, G J; Conner, C P

    2013-09-01

    The innovation process has often been represented as a linear process which funnels customer needs through various business and process filters. This method may be appropriate for some consumer products, but in the medical device industry there are some inherent limitations to the traditional innovation funnel approach. In the medical device industry, there are a number of stakeholders who need to have their voices heard throughout the innovation process. Each stakeholder has diverse and unique needs relating to the medical device, the needs of one may highly affect the needs of another, and the relationships between stakeholders may be tenuous. This paper describes the application of a spiral innovation process to the development of a medical device which considers three distinct stakeholder voices: the Voice of the Customer, the Voice of the Business and the Voice of the Technology. The process is presented as a case study focusing on the front-end redesign of a class III medical device for an orthopedics company. Starting from project initiation and scope alignment, the process describes four phases, Discover, Envision, Create, and Refine, and concludes with value assessment of the final design features.

  1. Device evaluation and coverage policy in workers' compensation: examples from Washington State.

    Science.gov (United States)

    Franklin, G M; Lifka, J; Milstein, J

    1998-09-25

    Workers' compensation health benefits are broader than general health benefits and include payment for medical and rehabilitation costs, associated indemnity (lost time) costs, and vocational rehabilitation (return-to-work) costs. In addition, cost liability is for the life of the claim (injury), rather than for each plan year. We examined device evaluation and coverage policy in workers' compensation over a 10-year period in Washington State. Most requests for device coverage in workers' compensation relate to the diagnosis, prognosis, or treatment of chronic musculoskeletal conditions. A number of specific problems have been recognized in making device coverage decisions within workers' compensation: (1) invasive devices with a high adverse event profile and history of poor outcomes could significantly increase both indemnity and medical costs; (2) many noninvasive devices, while having a low adverse event profile, have not proved effective for managing chronic musculoskeletal conditions relevant to injured workers; (3) some devices are marketed and billed as surrogate diagnostic tests for generally accepted, and more clearly proven, standard tests; (4) quality oversight of technology use among physicians may be inadequate; and (5) insurers' access to efficacy data adequate to make timely and appropriate coverage decisions in workers' compensation is often lacking. Emerging technology may substantially increase the costs of workers' compensation without significant evidence of health benefit for injured workers. To prevent ever-rising costs, we need to increase provider education and patient education and consent, involve the state medical society in coverage policy, and collect relevant outcomes data from healthcare providers.

  2. ISO 13485 a complete guide to quality management in the medical device industry

    CERN Document Server

    Abuhav, Itay

    2011-01-01

    Although complex and lengthy, the process of certification for the ISO 13485 can be easily mastered using the simple method outlined in ISO 13485: A Complete Guide to Quality Management in the Medical Device Industry. Written by an experienced industry professional, this practical book provides a complete guide to the ISO 13485 Standard certification for medical device manufacturing. Filled with examples drawn from the author's experience and spanning different sectors and fields of the medical device industry, the book translates the extra ordinary requirements and objectives of the standard

  3. ER-1A-DEL-92 regulation. Procedure for evaluation and registration of medical equipment

    International Nuclear Information System (INIS)

    2015-01-01

    The objectives of this regulation is to provide additional guidance on the method of evaluation and registration of a medical team, so it is used by manufacturers, health institutions, testing centers and other institutions related to the topic. The provisions of this regulation apply to domestically produced medical equipment in relation to the necessary assessment for registration purposes of a medical team. However, the evaluation process may require evaluations and tests not explicitly included in this regulation, so that at each stage of the process the Center for State Control of Medical Equipment (Center) set the requirements for each computer or device class in particular.

  4. Stretchable bioelectronics for medical devices and systems

    CERN Document Server

    Ghaffari, Roozbeh; Kim, Dae-Hyeong

    2016-01-01

    This book highlights recent advances in soft and stretchable biointegrated electronics. A renowned group of authors address key ideas in the materials, processes, mechanics, and devices of soft and stretchable electronics; the wearable electronics systems; and bioinspired and implantable biomedical electronics. Among the topics discussed are liquid metals, stretchable and flexible energy sources, skin-like devices, in vitro neural recording, and more. Special focus is given to recent advances in extremely soft and stretchable bio-inspired electronics with real-world clinical studies that validate the technology. Foundational theoretical and experimental aspects are also covered in relation to the design and application of these biointegrated electronics systems. This is an ideal book for researchers, engineers, and industry professionals involved in developing healthcare devices, medical tools and related instruments relevant to various clinical practices.

  5. Personal medical electronic devices and walk-through metal detector security systems: assessing electromagnetic interference effects.

    Science.gov (United States)

    Guag, Joshua; Addissie, Bisrat; Witters, Donald

    2017-03-20

    There have been concerns that Electromagnetic security systems such as walk-through metal detectors (WTMDs) can potentially cause electromagnetic interference (EMI) in certain active medical devices including implantable cardiac pacemakers and implantable neurostimulators. Incidents of EMI between WTMDs and active medical devices also known as personal medical electronic devices (PMED) continue to be reported. This paper reports on emission measurements of sample WTMDs and testing of 20 PMEDs in a WTMD simulation system. Magnetic fields from sample WTMD systems were characterized for emissions and exposure of certain PMEDs. A WTMD simulator system designed and evaluated by FDA in previous studies was used to mimic the PMED exposures to the waveform from sample WTMDs. The simulation system allows for controlled PMED exposure enabling careful study with adjustable magnetic field strengths and exposure duration, and provides flexibility for PMED exposure at elevated levels in order to study EMI effects on the PMED. The PMED samples consisted of six implantable cardiac pacemakers, six implantable cardioverter defibrillators (ICD), five implantable neurostimulators, and three insulin pumps. Each PMED was exposed in the simulator to the sample WTMD waveforms using methods based on appropriate consensus test standards for each of the device type. Testing the sample PMEDs using the WTMD simulator revealed EMI effects on two implantable pacemakers and one implantable neurostimulator for exposure field strength comparable to actual WTMD field strength. The observed effects were transient and the PMEDs returned to pre-exposure operation within a few seconds after removal from the simulated WTMD exposure fields. No EMI was observed for the sample ICDs or insulin pumps. The findings are consistent with earlier studies where certain sample PMEDs exhibited EMI effects. Clinical implications were not addressed in this study. Additional studies are needed to evaluate potential PMED

  6. How can cardiothoracic and vascular medical devices stay in the market?

    Science.gov (United States)

    Wong, Kathie A; Hodgson, Luke; Garas, George; Malietzis, George; Markar, Sheraz; Rao, Christopher; von Segesser, Ludwig K; Athanasiou, Thanos

    2016-12-01

    Surgeons, as the consumers, must engage in commercial activity regarding medical devices since it directly has impacts on surgical practice and patient outcomes. Unique features defy traditional economic convention in this specific market partly because consumers do not usually pay directly. Greater involvement with commercial activity means better post-market surveillance of medical devices which leads to improved patient safety. The medical device industry has exhibited astonishing levels of growth and profitability reaching $398 billion on a global scale with new product development focusing on unmet clinical need. The industry has rapidly emerged within the context of an ageing population and a global surge in healthcare spending. But the market remains fragmented. The split of consumer, purchaser and payer leads to clinical need driving demand for new product development. This demand contributes to potentially large profit margins mainly contained by regulatory burden and liability issues. Demographic trends, prevalence of diseases and a huge capacity to absorb technology have sustained near unparalleled growth. To stay in the market, incremental development over the short term is essentially aided by responsiveness to demand. Disruptive product development is now more likely to come from multinational companies, in an increasingly expensive, regulated industry. Understanding healthcare organization can help explain the highly complex process of diffusion of innovations in healthcare that include medical devices. The time has come for surgeons to become actively involved with all aspects of the medical device life cycle including commercial activity and post-market surveillance. This is vital for improving patient care and ensuring patient safety. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  7. Residual Isocyanates in Medical Devices and Products: A Qualitative and Quantitative Assessment

    Directory of Open Access Journals (Sweden)

    Gillian Franklin

    2016-01-01

    Full Text Available We conducted a pilot qualitative and quantitative assessment of residual isocyanates and their potential initial exposures in neonates, as little is known about their contact effect. After a neonatal intensive care unit (NICU stockroom inventory, polyurethane (PU and PU foam (PUF devices and products were qualitatively evaluated for residual isocyanates using Surface SWYPE ™ . Those containing isocyanates were quantitatively tested for methylene diphenyl diisocyanate (MDI species, using UPLC-UV-MS/MS method. Ten of 37 products and devices tested, indicated both free and bound residual surface isocyanates; PU/PUF pieces contained aromatic isocyanates; one product contained aliphatic isocyanates. Overall, quantified mean MDI concentrations were low (4,4‘-MDI = 0.52 to 140.1 pg/mg and (2,4‘-MDI = 0.01 to 4.48 pg/mg. The 4,4‘-MDI species had the highest measured concentration (280 pg/mg. Commonly used medical devices/products contain low, but measurable concentrations of residual isocyanates. Quantifying other isocyanate species and neonatal skin exposure to isocyanates from these devices and products requires further investigation.

  8. Security and privacy qualities of medical devices: an analysis of FDA postmarket surveillance.

    Science.gov (United States)

    Kramer, Daniel B; Baker, Matthew; Ransford, Benjamin; Molina-Markham, Andres; Stewart, Quinn; Fu, Kevin; Reynolds, Matthew R

    2012-01-01

    Medical devices increasingly depend on computing functions such as wireless communication and Internet connectivity for software-based control of therapies and network-based transmission of patients' stored medical information. These computing capabilities introduce security and privacy risks, yet little is known about the prevalence of such risks within the clinical setting. We used three comprehensive, publicly available databases maintained by the Food and Drug Administration (FDA) to evaluate recalls and adverse events related to security and privacy risks of medical devices. Review of weekly enforcement reports identified 1,845 recalls; 605 (32.8%) of these included computers, 35 (1.9%) stored patient data, and 31 (1.7%) were capable of wireless communication. Searches of databases specific to recalls and adverse events identified only one event with a specific connection to security or privacy. Software-related recalls were relatively common, and most (81.8%) mentioned the possibility of upgrades, though only half of these provided specific instructions for the update mechanism. Our review of recalls and adverse events from federal government databases reveals sharp inconsistencies with databases at individual providers with respect to security and privacy risks. Recalls related to software may increase security risks because of unprotected update and correction mechanisms. To detect signals of security and privacy problems that adversely affect public health, federal postmarket surveillance strategies should rethink how to effectively and efficiently collect data on security and privacy problems in devices that increasingly depend on computing systems susceptible to malware.

  9. Effects of Medical Device Regulations on the Development of Stand-Alone Medical Software: A Pilot Study.

    Science.gov (United States)

    Blagec, Kathrin; Jungwirth, David; Haluza, Daniela; Samwald, Matthias

    2018-01-01

    Medical device regulations which aim to ensure safety standards do not only apply to hardware devices but also to standalone medical software, e.g. mobile apps. To explore the effects of these regulations on the development and distribution of medical standalone software. We invited a convenience sample of 130 domain experts to participate in an online survey about the impact of current regulations on the development and distribution of medical standalone software. 21 respondents completed the questionnaire. Participants reported slight positive effects on usability, reliability, and data security of their products, whereas the ability to modify already deployed software and customization by end users were negatively impacted. The additional time and costs needed to go through the regulatory process were perceived as the greatest obstacles in developing and distributing medical software. Further research is needed to compare positive effects on software quality with negative impacts on market access and innovation. Strategies for avoiding over-regulation while still ensuring safety standards need to be devised.

  10. Using Survival Analysis to Evaluate Medical Equipment Battery Life.

    Science.gov (United States)

    Kuhajda, David

    2016-01-01

    As hospital medical device managers obtain more data, opportunities exist for using the data to improve medical device management, enhance patient safety, and evaluate costs of decisions. As a demonstration of the ability to use data analytics, this article applies survival analysis statistical techniques to assist in making decisions on medical equipment maintenance. The analysis was performed on a large amount of data related to failures of an infusion pump manufacturer's lithium battery and two aftermarket replacement lithium batteries from one hospital facility. The survival analysis resulted in statistical evidence showing that one of the third-party batteries had a lower survival curve than the infusion pump manufacturer's battery. This lower survival curve translates to a shorter expected life before replacement is needed. The data suggested that to limit unexpected failures, replacing batteries at a two-year interval, rather than the current industry recommendation of three years, may be warranted. For less than $5,400 in additional annual cost, the risk of unexpected battery failures can be reduced from an estimated 28% to an estimated 7%.

  11. 78 FR 66941 - Design Considerations for Pivotal Clinical Investigations for Medical Devices; Guidance for...

    Science.gov (United States)

    2013-11-07

    .... 66, rm. 2110, Silver Spring, MD 20993-0002, 301- 796-5750. For devices regulated by CBER: Stephen... the best clinical and statistical practices for investigational medical device studies. A medical...

  12. Evaluating Varied Label Designs for Use with Medical Devices: Optimized Labels Outperform Existing Labels in the Correct Selection of Devices and Time to Select.

    Directory of Open Access Journals (Sweden)

    Laura Bix

    Full Text Available Effective standardization of medical device labels requires objective study of varied designs. Insufficient empirical evidence exists regarding how practitioners utilize and view labeling.Measure the effect of graphic elements (boxing information, grouping information, symbol use and color-coding to optimize a label for comparison with those typical of commercial medical devices.Participants viewed 54 trials on a computer screen. Trials were comprised of two labels that were identical with regard to graphics, but differed in one aspect of information (e.g., one had latex, the other did not. Participants were instructed to select the label along a given criteria (e.g., latex containing as quickly as possible. Dependent variables were binary (correct selection and continuous (time to correct selection.Eighty-nine healthcare professionals were recruited at Association of Surgical Technologists (AST conferences, and using a targeted e-mail of AST members.Symbol presence, color coding and grouping critical pieces of information all significantly improved selection rates and sped time to correct selection (α = 0.05. Conversely, when critical information was graphically boxed, probability of correct selection and time to selection were impaired (α = 0.05. Subsequently, responses from trials containing optimal treatments (color coded, critical information grouped with symbols were compared to two labels created based on a review of those commercially available. Optimal labels yielded a significant positive benefit regarding the probability of correct choice ((P<0.0001 LSM; UCL, LCL: 97.3%; 98.4%, 95.5%, as compared to the two labels we created based on commercial designs (92.0%; 94.7%, 87.9% and 89.8%; 93.0%, 85.3% and time to selection.Our study provides data regarding design factors, namely: color coding, symbol use and grouping of critical information that can be used to significantly enhance the performance of medical device labels.

  13. Integrating health economics modeling in the product development cycle of medical devices: a Bayesian approach.

    Science.gov (United States)

    Vallejo-Torres, Laura; Steuten, Lotte M G; Buxton, Martin J; Girling, Alan J; Lilford, Richard J; Young, Terry

    2008-01-01

    Medical device companies are under growing pressure to provide health-economic evaluations of their products. Cost-effectiveness analyses are commonly undertaken as a one-off exercise at the late stage of development of new technologies; however, the benefits of an iterative use of economic evaluation during the development process of new products have been acknowledged in the literature. Furthermore, the use of Bayesian methods within health technology assessment has been shown to be of particular value in the dynamic framework of technology appraisal when new information becomes available in the life cycle of technologies. In this study, we set out a methodology to adapt these methods for their application to directly support investment decisions in a commercial setting from early stages of the development of new medical devices. Starting with relatively simple analysis from the very early development phase and proceeding to greater depth of analysis at later stages, a Bayesian approach facilitates the incorporation of all available evidence and would help companies to make better informed choices at each decision point.

  14. Concordance of Adherence Measurement Using Self-Reported Adherence Questionnaires and Medication Monitoring Devices: An Updated Review.

    Science.gov (United States)

    Monnette, Alisha; Zhang, Yichen; Shao, Hui; Shi, Lizheng

    2018-01-01

    As medication adherence continues to be a prevalent issue in today's society, the methods used to monitor medication-taking behaviors are constantly being re-evaluated and compared in search of the 'gold standard' measure. Our review aimed to assess the current literature surrounding the correlation between self-reported questionnaires (SRQs) and electronic monitoring devices to determine if these measures produce similar results. We performed a literature search from 2009 to 2017 using PubMed, PubMed In-Process and Non-Indexed, EMBASE, Ovid MEDLINE, and Ovid MEDLINE In-Process. A keyword search using the terms 'patient compliance', 'treatment compliance', 'medication adherence', 'drug monitoring', 'drug therapy', 'electronic', 'digital', 'computer', 'monitor', 'monitoring', 'drug', 'pharmaceutical preparations', 'compliance', and 'medications' was done to capture all articles. We included articles measuring adherence using both monitoring devices and SRQs. Thirty-five articles were included in this review. The average difference in measured adherence rates between the two measures was 9.2% (range -66.3 to 61.5). A majority (62.7%) of articles reported moderate (n = 12; 27.9%), high (n = 5, 11.6%), or significant (n = 10, 23.3%) correlations between SRQs and monitoring devices. Results from our review are consistent with previous studies, as we found that many of our studies produced moderate to high correlation between both SRQs and monitoring devices [Farmer, Clin Ther 21(6):1074-90 (1999), IMS Institute for Healthcare Informatics. Avoidable costs in US health care (2012), Patel et al., Respirology 18(3):546-52 (2013), Siracusa et al., J Cyst Fibros 14(5):621-6 (2015), Smith et al., Int J Cardiol 145(1):122-3 (2010)]. Our findings demonstrate that self-reported adherence produces comparable results to electronic monitoring devices. As there is not yet a 'gold standard' measure for monitoring patient adherence, SRQs and Medication Event Monitoring Systems

  15. OR.NET RT: how service-oriented medical device architecture meets real-time communication.

    Science.gov (United States)

    Pfeiffer, Jonas H; Kasparick, Martin; Strathen, Benjamin; Dietz, Christian; Dingler, Max E; Lueth, Tim C; Timmermann, Dirk; Radermacher, Klaus; Golatowski, Frank

    2018-02-23

    Today's landscape of medical devices is dominated by stand-alone systems and proprietary interfaces lacking cross-vendor interoperability. This complicates or even impedes the innovation of novel, intelligent assistance systems relying on the collaboration of medical devices. Emerging approaches use the service-oriented architecture (SOA) paradigm based on Internet protocol (IP) to enable communication between medical devices. While this works well for scenarios with no or only soft timing constraints, the underlying best-effort communication scheme is insufficient for time critical data. Real-time (RT) networks are able to reliably guarantee fixed latency boundaries, for example, by using time division multiple access (TDMA) communication patterns. However, deterministic RT networks come with their own limitations such as tedious, inflexible configuration and a more restricted bandwidth allocation. In this contribution we overcome the drawbacks of both approaches by describing and implementing mechanisms that allow the two networks to interact. We introduce the first implementation of a medical device network that offers hard RT guarantees for control and sensor data and integrates into SOA networks. Based on two application examples we show how the flexibility of SOA networks and the reliability of RT networks can be combined to achieve an open network infrastructure for medical devices in the operating room (OR).

  16. Scouting For Approval: Lessons on Medical Device Regulation in an Era of Crowdfunding from Scanadu's "Scout".

    Science.gov (United States)

    Smith, Colleen

    2015-01-01

    Internet crowdfunding, a new and increasingly popular method of raising capital to develop products and businesses, has recently come into conflict with the Food and Drug Administration's (FDA's) regulation of medical devices. This Article examines the issues that arise when companies pre-sell medical devices via crowdfunding campaigns before gaining FDA approval of the devices. Because Internet crowdfunding has only been in use for a few years, little has been written about it academically, particularly about its interaction with FDA regulations. The rising interest in crowdfunding, coupled with the downturn in investment in the American medical device industry, make this a salient issue that is ripe for FDA review. This Article uses the crowdfunding campaign Scanadu, a medical device company, conducted in 2013 to raise money to develop its in-home diagnostic device, the "Scout," as a starting point for this analysis. Because it is extremely costly to develop a device and obtain FDA approval, medical device companies should be able to utilize crowdfunding to raise the necessary capital. However, because of the possible dangers medical devices pose, FDA needs to review the risks created by allowing companies to crowdfund medical devices and should issue guidance to help companies comply with FDA regulations while still allowing them to take advantage of the benefits of crowdfunding. This guidance should ensure the continued commitment to consumer safety that is at the core of FDA regulation.

  17. Monitoring of Vital Signs with Flexible and Wearable Medical Devices.

    Science.gov (United States)

    Khan, Yasser; Ostfeld, Aminy E; Lochner, Claire M; Pierre, Adrien; Arias, Ana C

    2016-06-01

    Advances in wireless technologies, low-power electronics, the internet of things, and in the domain of connected health are driving innovations in wearable medical devices at a tremendous pace. Wearable sensor systems composed of flexible and stretchable materials have the potential to better interface to the human skin, whereas silicon-based electronics are extremely efficient in sensor data processing and transmission. Therefore, flexible and stretchable sensors combined with low-power silicon-based electronics are a viable and efficient approach for medical monitoring. Flexible medical devices designed for monitoring human vital signs, such as body temperature, heart rate, respiration rate, blood pressure, pulse oxygenation, and blood glucose have applications in both fitness monitoring and medical diagnostics. As a review of the latest development in flexible and wearable human vitals sensors, the essential components required for vitals sensors are outlined and discussed here, including the reported sensor systems, sensing mechanisms, sensor fabrication, power, and data processing requirements. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Medical devices and the Middle East: market, regulation, and reimbursement in Gulf Cooperation Council states

    Directory of Open Access Journals (Sweden)

    Howard JJ

    2014-11-01

    Full Text Available Jason J Howard Division of Paediatric Orthopaedics, Department of Surgery, Sidra Medical and Research Center, Doha, Qatar Abstract: With some of the richest economies in the world, the Gulf Cooperation Council (GCC is undergoing rapid growth not only in its population but also in health care expenditure. Despite the GCC's abundance of hydrocarbon-based wealth, the drivers of the medical device industry in the GCC are still in flux, with gains yet to be made in areas of infrastructure, regulation, and reimbursement. However, the regional disease burden, expanding health insurance penetration, increasing privatization, and a desire to attract skilled expatriate health care providers have led to favorable conditions for the medical device market in the GCC. The purpose of this article is to investigate the current state of the GCC medical device industry, with respect to market, regulation, and reimbursement, paying special attention to the three largest medical device markets: Saudi Arabia, the United Arab Emirates, and Qatar. The GCC would seem to represent fertile ground for the development of medical technologies, especially those in line with the regional health priorities of the respective member states. Keywords: medical devices, regulation, reimbursement, Middle East 

  19. Mobile devices in medicine: a survey of how medical students, residents, and faculty use smartphones and other mobile devices to find information*

    Science.gov (United States)

    Boruff, Jill T.; Storie, Dale

    2014-01-01

    Objectives: The research investigated the extent to which students, residents, and faculty members in Canadian medical faculties use mobile devices, such as smartphones (e.g., iPhone, Android, Blackberry) and tablet computers (e.g., iPad), to answer clinical questions and find medical information. The results of this study will inform how health libraries can effectively support mobile technology and collections. Methods: An electronic survey was distributed by medical librarians at four Canadian universities to medical students, residents, and faculty members via departmental email discussion lists, personal contacts, and relevant websites. It investigated the types of information sought, facilitators to mobile device use in medical information seeking, barriers to access, support needs, familiarity with institutionally licensed resources, and most frequently used resources. Results: The survey of 1,210 respondents indicated widespread use of smartphones and tablets in clinical settings in 4 Canadian universities. Third- and fourth-year undergraduate students (i.e., those in their clinical clerkships) and medical residents, compared to other graduate students and faculty, used their mobile devices more often, used them for a broader range of activities, and purchased more resources for their devices. Conclusions: Technological and intellectual barriers do not seem to prevent medical trainees and faculty from regularly using mobile devices for their medical information searches; however, barriers to access and lack of awareness might keep them from using reliable, library-licensed resources. Implications: Libraries should focus on providing access to a smaller number of highly used mobile resources instead of a huge collection until library-licensed mobile resources have streamlined authentication processes. PMID:24415916

  20. Mobile devices in medicine: a survey of how medical students, residents, and faculty use smartphones and other mobile devices to find information.

    Science.gov (United States)

    Boruff, Jill T; Storie, Dale

    2014-01-01

    The research investigated the extent to which students, residents, and faculty members in Canadian medical faculties use mobile devices, such as smartphones (e.g., iPhone, Android, Blackberry) and tablet computers (e.g., iPad), to answer clinical questions and find medical information. The results of this study will inform how health libraries can effectively support mobile technology and collections. An electronic survey was distributed by medical librarians at four Canadian universities to medical students, residents, and faculty members via departmental email discussion lists, personal contacts, and relevant websites. It investigated the types of information sought, facilitators to mobile device use in medical information seeking, barriers to access, support needs, familiarity with institutionally licensed resources, and most frequently used resources. The survey of 1,210 respondents indicated widespread use of smartphones and tablets in clinical settings in 4 Canadian universities. Third- and fourth-year undergraduate students (i.e., those in their clinical clerkships) and medical residents, compared to other graduate students and faculty, used their mobile devices more often, used them for a broader range of activities, and purchased more resources for their devices. Technological and intellectual barriers do not seem to prevent medical trainees and faculty from regularly using mobile devices for their medical information searches; however, barriers to access and lack of awareness might keep them from using reliable, library-licensed resources. Libraries should focus on providing access to a smaller number of highly used mobile resources instead of a huge collection until library-licensed mobile resources have streamlined authentication processes.

  1. Medical devices made into weapons by prisoners: an unrecognized risk.

    Science.gov (United States)

    Hayden, J W; Laney, C; Kellermann, A L

    1995-12-01

    The alteration of a knee immobilizer into a sharp weapon by a prisoner prompted us to survey neighboring penal institutions to determine the frequency of such events. We mailed a nine-item survey to all detention facilities in Tennessee, Arkansas, and Mississippi. A second survey was sent to nonresponding institutions 6 weeks after the initial mailing. The Regional Medical Center at Memphis, the designated facility for evaluation and treatment of prisoners from the county jail and state penitentiary. Survey respondents included 25 state penitentiaries, 31 county jails, 1 state minimum-security facility, 1 state maximum-security facility, 1 work-release center, 1 county detention center for drunken-driving offenders, and 1 federal penitentiary. Of the 81 institutions surveyed, 77% responded to one of the two mailings. Forty percent responded in the affirmative when asked whether stolen or unauthorized medical equipment from outside their institutions had been discovered among inmates. When respondents were questioned as to whether medical equipment, prescribed or not, had been used or altered in a criminal manner, 34% responded "yes." Medications and medical appliances were listed in the responses. A survey of 81 local and neighboring penal institutions in a three-state area revealed that the illicit use of medicine and medical devices by prisoners is a legitimate safety concern of prison personnel and health care workers when medical care for inmates must be sought outside the security of their institutions. The modification of medical equipment into weapons by incarcerated patients, although clearly recognized as a security and safety problem by police authorities, appears to be unappreciated by health care workers providing episodic care to inmates.

  2. Implantable Medical Devices; Networking Security Survey

    OpenAIRE

    Siamak Aram; Rouzbeh A. Shirvani; Eros G. Pasero; Mohamd F. Chouikha

    2016-01-01

    The industry of implantable medical devices (IMDs) is constantly evolving, which is dictated by the pressing need to comprehensively address new challenges in the healthcare field. Accordingly, IMDs are becoming more and more sophisticated. Not long ago, the range of IMDs’ technical capacities was expanded, making it possible to establish Internet connection in case of necessity and/or emergency situation for the patient. At the same time, while the web connectivity of today’s implantable dev...

  3. Security and Privacy Qualities of Medical Devices: An Analysis of FDA Postmarket Surveillance

    Science.gov (United States)

    Kramer, Daniel B.; Baker, Matthew; Ransford, Benjamin; Molina-Markham, Andres; Stewart, Quinn; Fu, Kevin; Reynolds, Matthew R.

    2012-01-01

    Background Medical devices increasingly depend on computing functions such as wireless communication and Internet connectivity for software-based control of therapies and network-based transmission of patients’ stored medical information. These computing capabilities introduce security and privacy risks, yet little is known about the prevalence of such risks within the clinical setting. Methods We used three comprehensive, publicly available databases maintained by the Food and Drug Administration (FDA) to evaluate recalls and adverse events related to security and privacy risks of medical devices. Results Review of weekly enforcement reports identified 1,845 recalls; 605 (32.8%) of these included computers, 35 (1.9%) stored patient data, and 31 (1.7%) were capable of wireless communication. Searches of databases specific to recalls and adverse events identified only one event with a specific connection to security or privacy. Software-related recalls were relatively common, and most (81.8%) mentioned the possibility of upgrades, though only half of these provided specific instructions for the update mechanism. Conclusions Our review of recalls and adverse events from federal government databases reveals sharp inconsistencies with databases at individual providers with respect to security and privacy risks. Recalls related to software may increase security risks because of unprotected update and correction mechanisms. To detect signals of security and privacy problems that adversely affect public health, federal postmarket surveillance strategies should rethink how to effectively and efficiently collect data on security and privacy problems in devices that increasingly depend on computing systems susceptible to malware. PMID:22829874

  4. Framework conditions and requirements to ensure the technical functional safety of reprocessed medical devices.

    Science.gov (United States)

    Kraft, Marc

    2008-09-03

    Testing and restoring technical-functional safety is an essential part of medical device reprocessing. Technical functional tests have to be carried out on the medical device in the course of the validation of reprocessing procedures. These ensure (in addition to the hygiene tests) that the reprocessing procedure is suitable for the medical device. Functional tests are, however, also a part of reprocessing procedures. As a stage in the reprocessing, they ensure for the individual medical device that no damage or other changes limit the performance. When determining which technical-functional tests are to be carried out, the current technological standard has to be taken into account in the form of product-specific and process-oriented norms. Product-specific norms primarily define safety-relevant requirements. The risk management method described in DIN EN ISO 14971 is the basis for recognising hazards; the likelihood of such hazards arising can be minimised through additional technical-functional tests, which may not yet have been standardised. Risk management is part of a quality management system, which must be bindingly certified for manufacturers and processors of critical medical devices with particularly high processing demands by a body accredited by the competent authority.

  5. 77 FR 3781 - Pediatric Medical Devices; Public Workshop; Reopening of Comment Period

    Science.gov (United States)

    2012-01-25

    ... devices. DATES: Submit either electronic or written comments by March 5, 2012. ADDRESSES: Submit.... Designing pediatric medical devices can be challenging; children are often smaller and more active than adults; body structures and functions change throughout childhood, and children may be long-term device...

  6. A Maturity Grid Assessment Tool for Environmentally Conscious Design in the Medical Device Industry

    DEFF Research Database (Denmark)

    Moultrie, James; Sutcliffe, Laura Francesca Rose; Maier, Anja

    2016-01-01

    . This intervention tool provides designers and product marketers with insights on how to improve the design of their medical devices and specifically allows consideration of the complex trade-offs between decisions that influence different life-cycle stages. Through the tool, actionable insight is created......The medical device industry is growing increasingly concerned about environmental impact of products. Whilst there are many tools aiming to support environmentally conscious design, they are typically complex to use, demand substantial data collection and are not tailored to the specific needs...... of the medical device sector. This paper reports on the development of a Maturity Grid to address this gap. This novel design tool was developed iteratively through application in five case studies. The tool captures principles of eco-design for medical devices in a simple form, designed to be used by a team...

  7. Initiatives in the Australian Medical Devices Industry

    International Nuclear Information System (INIS)

    Whelan, Luke

    2005-01-01

    The medical device industry is as diverse as it is specialised and calls on the innovative use of design and components and utilises all facets of precision manufacturing from printed circuit boards, injection-moulded plastics to engineering, using a wide range of materials. It generally requires exacting standards, starting with design, particularly for devices that are invasive or have direct contact with the human body. Of course this brings the further consideration of sterilisation and whether it is for single or multiple use. There is an ever-present need to produce more accurate less invasive and cheaper devices. The driving motivation appears to be meeting clinical needs at a reduced cost. The push to treat people outside the hospital is growing, creating new demands and directions. The advent of the Internet and wireless technology has opened a whole new direction of research and development opportunities

  8. 78 FR 27971 - Dental Products Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2013-05-13

    ...] Dental Products Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and Drug...: Dental Products Panel of the Medical Devices Advisory Committee. General Function of the Committee: To... regulatory classification for dental devices known as Endosseous Dental Implants (Blade-form), one of the...

  9. A Collaborative Evaluation Framework for Biometric Connected Devices in Healthcare.

    Science.gov (United States)

    Farnia, Troskah; Jaulent, Marie Christine; Marchand, Guillaume; Yasini, Mobin

    2017-01-01

    A large number of biometric connected devices are currently available with a variety of designs. Healthcare users cannot easily choose the reliable ones that correspond the best to their healthcare problems. The existing evaluation methods do not consider at the same time aspects of connectivity and healthcare usage. In this study, a collaborative evaluation framework for biometric connected devices in healthcare usage is proposed. This framework contains six dimensions: medical validity, technical reliability, usability, ergonomy, legal compliance, and accuracy of measurements. In a first step, these dimensions were assessed by designing a self administered questionnaire answered by the stakeholders (patients, health professionals, payers, and manufacturers). A case study was then carried out in a second step to test this framework in a project of telemonitoring for heart failure patients. The results are in favor of the efficiency of the proposed framework as a decision making tool in healthcare usage.

  10. Biomaterials and medical devices a perspective from an emerging country

    CERN Document Server

    Hermawan, Hendra

    2016-01-01

    This book presents an introduction to biomaterials with the focus on the current development and future direction of biomaterials and medical devices research and development in Indonesia. It is the first biomaterials book written by selected academic and clinical experts experts on biomaterials and medical devices from various institutions and industries in Indonesia. It serves as a reference source for researchers starting new projects, for companies developing and marketing products and for governments setting new policies. Chapter one covers the fundamentals of biomaterials, types of biomaterials, their structures and properties and the relationship between them. Chapter two discusses unconventional processing of biomaterials including nano-hybrid organic-inorganic biomaterials. Chapter three addresses biocompatibility issues including in vitro cytotoxicity, genotoxicity, in vitro cell models, biocompatibility data and its related failure. Chapter four describes degradable biomaterial for medical implants...

  11. Evaluating a medical error taxonomy.

    OpenAIRE

    Brixey, Juliana; Johnson, Todd R.; Zhang, Jiajie

    2002-01-01

    Healthcare has been slow in using human factors principles to reduce medical errors. The Center for Devices and Radiological Health (CDRH) recognizes that a lack of attention to human factors during product development may lead to errors that have the potential for patient injury, or even death. In response to the need for reducing medication errors, the National Coordinating Council for Medication Errors Reporting and Prevention (NCC MERP) released the NCC MERP taxonomy that provides a stand...

  12. Additive Manufacturing for Robust and Affordable Medical Devices

    OpenAIRE

    Wolozny Gomez Robelo, Daniel Andre

    2016-01-01

    Additive manufacturing in the form of 3D printing is a revolutionary technology that has developed within the last two decades. Its ability to print an object with accurate features down to the micro scale have made its use in medical devices and research feasible. A range of life-saving technologies can now go from the laboratory and into field with the application of 3D-printing. This technology can be applied to medical diagnosis of patients in at-risk populations. Living biosensors a...

  13. An extended protocol for usability validation of medical devices: Research design and reference model.

    Science.gov (United States)

    Schmettow, Martin; Schnittker, Raphaela; Schraagen, Jan Maarten

    2017-05-01

    This paper proposes and demonstrates an extended protocol for usability validation testing of medical devices. A review of currently used methods for the usability evaluation of medical devices revealed two main shortcomings. Firstly, the lack of methods to closely trace the interaction sequences and derive performance measures. Secondly, a prevailing focus on cross-sectional validation studies, ignoring the issues of learnability and training. The U.S. Federal Drug and Food Administration's recent proposal for a validation testing protocol for medical devices is then extended to address these shortcomings: (1) a novel process measure 'normative path deviations' is introduced that is useful for both quantitative and qualitative usability studies and (2) a longitudinal, completely within-subject study design is presented that assesses learnability, training effects and allows analysis of diversity of users. A reference regression model is introduced to analyze data from this and similar studies, drawing upon generalized linear mixed-effects models and a Bayesian estimation approach. The extended protocol is implemented and demonstrated in a study comparing a novel syringe infusion pump prototype to an existing design with a sample of 25 healthcare professionals. Strong performance differences between designs were observed with a variety of usability measures, as well as varying training-on-the-job effects. We discuss our findings with regard to validation testing guidelines, reflect on the extensions and discuss the perspectives they add to the validation process. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. [Medical technology and medical education].

    Science.gov (United States)

    von Mallek, D; Biersack, H-J; Mull, R; Wilhelm, K; Heinz, B; Mellert, F

    2010-08-01

    The education of medical professionals is divided into medical studies, postgraduate training leading to the qualification as a specialist, and continuing professional development. During education, all scientific knowledge and practical skills are to be acquired, which enable the physician to practice responsibly in a specialized medical area. In the present article, relevant curricula are analyzed regarding the consideration of medical device-related topics, as the clinical application of medical technology has reached a central position in modern patient care. Due to the enormous scientific and technical progress, this area has become as important as pharmacotherapy. Our evaluation shows that medical device-related topics are currently underrepresented in the course of medical education and training and should be given greater consideration in all areas of medical education. Possible solutions are presented.

  15. Classroom to Clinic: Merging Education and Research to Efficiently Prototype Medical Devices.

    Science.gov (United States)

    Hanumara, Nevan C; Begg, Nikolai D; Walsh, Conor; Custer, David; Gupta, Rajiv; Osborn, Lynn R; Slocum, Alexander H

    2013-01-01

    Innovation in patient care requires both clinical and technical skills, and this paper presents the methods and outcomes of a nine-year, clinical-academic collaboration to develop and evaluate new medical device technologies, while teaching mechanical engineering. Together, over the course of a single semester, seniors, graduate students, and clinicians conceive, design, build, and test proof-of-concept prototypes. Projects initiated in the course have generated intellectual property and peer-reviewed publications, stimulated further research, furthered student and clinician careers, and resulted in technology licenses and start-up ventures.

  16. Integrating the results of user research into medical device development: insights from a case study.

    Science.gov (United States)

    Martin, Jennifer L; Barnett, Julie

    2012-07-19

    It is well established that considering users is an important aspect of medical device development. However it is also well established that there are numerous barriers to successfully conducting user research and integrating the results into product development. It is not sufficient to simply conduct user research, it must also be effectively integrated into product development. A case study of the development of a new medical imaging device was conducted to examine in detail how users were involved in a medical device development project. Two user research studies were conducted: a requirements elicitation interview study and an early prototype evaluation using contextual inquiry. A descriptive in situ approach was taken to investigate how these studies contributed to the product development process and how the results of this work influenced the development of the technology. Data was collected qualitatively through interviews with the development team, participant observation at development meetings and document analysis. The focus was on investigating the barriers that exist to prevent user data from being integrated into product development. A number of individual, organisational and system barriers were identified that functioned to prevent the results of the user research being fully integrated into development. The user and technological aspects of development were seen as separate work streams during development. The expectations of the developers were that user research would collect requirements for the appearance of the device, rather than challenge its fundamental concept. The manner that the user data was communicated to the development team was not effective in conveying the significance or breadth of the findings. There are a range of informal and formal organisational processes that can affect the uptake of user data during medical device development. Adopting formal decision making processes may assist manufacturers to take a more integrated and

  17. Integrating the results of user research into medical device development: insights from a case study

    Directory of Open Access Journals (Sweden)

    Martin Jennifer L

    2012-07-01

    Full Text Available Abstract Background It is well established that considering users is an important aspect of medical device development. However it is also well established that there are numerous barriers to successfully conducting user research and integrating the results into product development. It is not sufficient to simply conduct user research, it must also be effectively integrated into product development. Methods A case study of the development of a new medical imaging device was conducted to examine in detail how users were involved in a medical device development project. Two user research studies were conducted: a requirements elicitation interview study and an early prototype evaluation using contextual inquiry. A descriptive in situ approach was taken to investigate how these studies contributed to the product development process and how the results of this work influenced the development of the technology. Data was collected qualitatively through interviews with the development team, participant observation at development meetings and document analysis. The focus was on investigating the barriers that exist to prevent user data from being integrated into product development. Results A number of individual, organisational and system barriers were identified that functioned to prevent the results of the user research being fully integrated into development. The user and technological aspects of development were seen as separate work streams during development. The expectations of the developers were that user research would collect requirements for the appearance of the device, rather than challenge its fundamental concept. The manner that the user data was communicated to the development team was not effective in conveying the significance or breadth of the findings. Conclusion There are a range of informal and formal organisational processes that can affect the uptake of user data during medical device development. Adopting formal decision

  18. A user-centred approach to requirements elicitation in medical device development: a case study from an industry perspective.

    Science.gov (United States)

    Martin, Jennifer L; Clark, Daniel J; Morgan, Stephen P; Crowe, John A; Murphy, Elizabeth

    2012-01-01

    The healthcare industry is dependent upon the provision of well designed medical devices. To achieve this it is recommended that user-centred design should begin early, and continue throughout device development. This is a challenge, particularly for smaller companies who may lack the necessary expertise and knowledge. The aim of this study was to conduct a rigorous yet focused investigation into the user requirements for a new medical imaging device. Open-ended semi-structured interviews were conducted with potential clinical users of the device to investigate the clinical need for the device and the potential benefits for patients and clinical users. The study identified a number of new and significant clinical needs that suggested that the concept of the device should be fundamentally changed. The clinical and organisational priorities of the clinical users were identified, as well as a number of factors that would act as barriers to the safe and effective adoption of the device. The developers reported that this focused approach to early requirements elicitation would result in an improved product, reduce the time to market, and save the time and cost of producing and evaluating an inappropriate prototype. Copyright © 2011 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  19. Medical devices of the head, neck, and spine.

    Science.gov (United States)

    Hunter, Tim B; Yoshino, Mark T; Dzioba, Robert B; Light, Rick A; Berger, William G

    2004-01-01

    There are many medical devices used for head, neck, and spinal diseases and injuries, and new devices are constantly being introduced. Many of the newest devices are variations on a previous theme. Knowing the specific name of a device is not important. It is important to recognize the presence of a device and to have an understanding of its function as well as to be able to recognize the complications associated with its use. The article discusses the most common and important devices of the head, neck, and spine, including cerebrospinal fluid shunts and the Codman Hakim programmable valve; subdural drainage catheters, subdural electrodes, intracranial electrodes, deep brain stimulators, and cerebellar electrodes; coils, balloons, adhesives, particles, and aneurysm clips; radiation therapy catheters, intracranial balloons for drug installation, and carmustine wafers; hearing aids, cochlear implants, and ossicular reconstruction prostheses; orbital prostheses, intraocular silicone oil, and lacrimal duct stents; anterior and posterior cervical plates, posterior cervical spine wiring, odontoid fracture fixation devices, cervical collars and halo vests; thoracic and lumbar spine implants, anterior and posterior instrumentation for the thoracic and lumbar spine, vertebroplasty, and artificial disks; spinal column stimulators, bone stimulators, intrathecal drug delivery pumps, and sacral stimulators; dental and facial implant devices; gastric and tracheal tubes; vagus nerve stimulators; lumboperitoneal shunts; and temperature- and oxygen-sensing probes. Copyright RSNA, 2004

  20. Metrological Reliability of Medical Devices

    Science.gov (United States)

    Costa Monteiro, E.; Leon, L. F.

    2015-02-01

    The prominent development of health technologies of the 20th century triggered demands for metrological reliability of physiological measurements comprising physical, chemical and biological quantities, essential to ensure accurate and comparable results of clinical measurements. In the present work, aspects concerning metrological reliability in premarket and postmarket assessments of medical devices are discussed, pointing out challenges to be overcome. In addition, considering the social relevance of the biomeasurements results, Biometrological Principles to be pursued by research and innovation aimed at biomedical applications are proposed, along with the analysis of their contributions to guarantee the innovative health technologies compliance with the main ethical pillars of Bioethics.

  1. 75 FR 18219 - Drug and Medical Device Forum on Food and Drug Administration Drug and Device Requirements and...

    Science.gov (United States)

    2010-04-09

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0142] Drug and Medical Device Forum on Food and Drug Administration Drug and Device Requirements and Supplier Controls; Public Educational Forum AGENCY: Food and Drug Administration, HHS. ACTION: Notice of public...

  2. Evaluating and improving the performance of thin film force sensors within body and device interfaces.

    Science.gov (United States)

    Likitlersuang, Jirapat; Leineweber, Matthew J; Andrysek, Jan

    2017-10-01

    Thin film force sensors are commonly used within biomechanical systems, and at the interface of the human body and medical and non-medical devices. However, limited information is available about their performance in such applications. The aims of this study were to evaluate and determine ways to improve the performance of thin film (FlexiForce) sensors at the body/device interface. Using a custom apparatus designed to load the sensors under simulated body/device conditions, two aspects were explored relating to sensor calibration and application. The findings revealed accuracy errors of 23.3±17.6% for force measurements at the body/device interface with conventional techniques of sensor calibration and application. Applying a thin rigid disc between the sensor and human body and calibrating the sensor using compliant surfaces was found to substantially reduce measurement errors to 2.9±2.0%. The use of alternative calibration and application procedures is recommended to gain acceptable measurement performance from thin film force sensors in body/device applications. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  3. Design of point-of-care (POC) microfluidic medical diagnostic devices

    Science.gov (United States)

    Leary, James F.

    2018-02-01

    Design of inexpensive and portable hand-held microfluidic flow/image cytometry devices for initial medical diagnostics at the point of initial patient contact by emergency medical personnel in the field requires careful design in terms of power/weight requirements to allow for realistic portability as a hand-held, point-of-care medical diagnostics device. True portability also requires small micro-pumps for high-throughput capability. Weight/power requirements dictate use of super-bright LEDs and very small silicon photodiodes or nanophotonic sensors that can be powered by batteries. Signal-to-noise characteristics can be greatly improved by appropriately pulsing the LED excitation sources and sampling and subtracting noise in between excitation pulses. The requirements for basic computing, imaging, GPS and basic telecommunications can be simultaneously met by use of smartphone technologies, which become part of the overall device. Software for a user-interface system, limited real-time computing, real-time imaging, and offline data analysis can be accomplished through multi-platform software development systems that are well-suited to a variety of currently available cellphone technologies which already contain all of these capabilities. Microfluidic cytometry requires judicious use of small sample volumes and appropriate statistical sampling by microfluidic cytometry or imaging for adequate statistical significance to permit real-time (typically medical decisions for patients at the physician's office or real-time decision making in the field. One or two drops of blood obtained by pin-prick should be able to provide statistically meaningful results for use in making real-time medical decisions without the need for blood fractionation, which is not realistic in the field.

  4. #DDOD Use Case: Consolidated reporting of medical device recalls

    Data.gov (United States)

    U.S. Department of Health & Human Services — SUMMARY DDOD use case request for consolidated, consistent reporting of medical device recalls. WHAT IS A USE CASE? A “Use Case” is a request that was made by the...

  5. A service protocol for post-processing of medical images on the mobile device

    Science.gov (United States)

    He, Longjun; Ming, Xing; Xu, Lang; Liu, Qian

    2014-03-01

    With computing capability and display size growing, the mobile device has been used as a tool to help clinicians view patient information and medical images anywhere and anytime. It is uneasy and time-consuming for transferring medical images with large data size from picture archiving and communication system to mobile client, since the wireless network is unstable and limited by bandwidth. Besides, limited by computing capability, memory and power endurance, it is hard to provide a satisfactory quality of experience for radiologists to handle some complex post-processing of medical images on the mobile device, such as real-time direct interactive three-dimensional visualization. In this work, remote rendering technology is employed to implement the post-processing of medical images instead of local rendering, and a service protocol is developed to standardize the communication between the render server and mobile client. In order to make mobile devices with different platforms be able to access post-processing of medical images, the Extensible Markup Language is taken to describe this protocol, which contains four main parts: user authentication, medical image query/ retrieval, 2D post-processing (e.g. window leveling, pixel values obtained) and 3D post-processing (e.g. maximum intensity projection, multi-planar reconstruction, curved planar reformation and direct volume rendering). And then an instance is implemented to verify the protocol. This instance can support the mobile device access post-processing of medical image services on the render server via a client application or on the web page.

  6. [Projects to accelerate the practical use of innovative medical devices to collaborate with TWIns, Center for Advanced Biomedical Sciences, Waseda University and School of Engineering, The University of Tokyo].

    Science.gov (United States)

    Niimi, Shingo; Umezu, Mitsuo; Iseki, Hiroshi; Harada, Hiroshi Kasanuki Noboru; Mitsuishi, Mamoru; Kitamori, Takehiko; Tei, Yuichi; Nakaoka, Ryusuke; Haishima, Yuji

    2014-01-01

    Division of Medical Devices has been conducting the projects to accelerate the practical use of innovative medical devices to collaborate with TWIns, Center for Advanced Biomedical Sciences, Waseda University and School of Engineering, The University of Tokyo. The TWIns has been studying to aim at establishment of preclinical evaluation methods by "Engineering Based Medicine", and established Regulatory Science Institute for Medical Devices. School of Engineering, The University of Tokyo has been studying to aim at establishment of assessment methodology for innovative minimally invasive therapeutic devices, materials, and nanobio diagnostic devices. This report reviews the exchanges of personnel, the implement systems and the research progress of these projects.

  7. Clinical evaluation of cardiovascular devices: principles, problems, and proposals for European regulatory reform. Report of a policy conference of the European Society of Cardiology.

    Science.gov (United States)

    Fraser, Alan G; Daubert, Jean-Claude; Van de Werf, Frans; Estes, N A Mark; Smith, Sidney C; Krucoff, Mitchell W; Vardas, Panos E; Komajda, Michel

    2011-07-01

    The European Commission announced in 2008 that a fundamental revision of the medical device directives is being considered in order to clarify and strengthen the current legal framework. The system for testing and approving devices in Europe was established >20 years ago as a 'New Approach' to a previously little-regulated industry. It is recognized by many that the regulatory system has not kept pace with technological advances and changing patterns of medical practice. New legislation will be drafted during 2011, but medical experts have been little involved in this important process. This context makes it an opportune time for a professional association to advise from both clinical and academic perspectives about changes which should be made to improve the safety and efficacy of devices used in clinical practice and to develop more appropriate systems for their clinical evaluation and post-marketing surveillance. This report summarizes how medical devices are regulated and it reviews some serious clinical problems that have occurred with cardiovascular devices. Finally, it presents the main recommendations from a Policy Conference on the Clinical Evaluation of Cardiovascular Devices that was held at the European Heart House in January 2011.

  8. Pediatric medical device development by surgeons via capstone engineering design programs.

    Science.gov (United States)

    Sack, Bryan S; Elizondo, Rodolfo A; Huang, Gene O; Janzen, Nicolette; Espinoza, Jimmy; Sanz-Cortes, Magdalena; Dietrich, Jennifer E; Hakim, Julie; Richardson, Eric S; Oden, Maria; Hanks, John; Haridas, Balakrishna; Hury, James F; Koh, Chester J

    2018-03-01

    There is a need for pediatric medical devices that accommodate the unique physiology and anatomy of pediatric patients that is increasingly receiving more attention. However, there is limited literature on the programs within children's hospitals and academia that can support pediatric device development. We describe our experience with pediatric device design utilizing collaborations between a children's hospital and two engineering schools. Utilizing the academic year as a timeline, unmet pediatric device needs were identified by surgical faculty and matched with an engineering mentor and a team of students within the Capstone Engineering Design programs at two universities. The final prototypes were showcased at the end of the academic year and if appropriate, provisional patent applications were filed. All twelve teams successfully developed device prototypes, and five teams obtained provisional patents. The prototypes that obtained provisional patents included a non-operative ureteral stent removal system, an evacuation device for small kidney stone fragments, a mechanical leech, an anchoring system of the chorio-amniotic membranes during fetal surgery, and a fetal oxygenation monitor during fetoscopic procedures. Capstone Engineering Design programs in partnership with surgical faculty at children's hospitals can play an effective role in the prototype development of novel pediatric medical devices. N/A - No clinical subjects or human testing was performed. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Wireless communication with implanted medical devices using the conductive properties of the body.

    Science.gov (United States)

    Ferguson, John E; Redish, A David

    2011-07-01

    Many medical devices that are implanted in the body use wires or wireless radiofrequency telemetry to communicate with circuitry outside the body. However, the wires are a common source of surgical complications, including breakage, infection and electrical noise. In addition, radiofrequency telemetry requires large amounts of power and results in low-efficiency transmission through biological tissue. As an alternative, the conductive properties of the body can be used to enable wireless communication with implanted devices. In this article, several methods of intrabody communication are described and compared. In addition to reducing the complications that occur with current implantable medical devices, intrabody communication can enable novel types of miniature devices for research and clinical applications.

  10. Post-market clinical research conducted by medical device manufacturers: a cross-sectional survey.

    Science.gov (United States)

    Ross, Joseph S; Blount, Katrina L; Ritchie, Jessica D; Hodshon, Beth; Krumholz, Harlan M

    2015-01-01

    In the US, once a medical device is made available for use, several requirements have been established by the US Food and Drug Administration (FDA) to ensure ongoing post-market surveillance of device safety and effectiveness. Our objective was to determine how commonly medical device manufacturers initiate post-market clinical studies or augment FDA post-market surveillance requirements for higher-risk devices that are most often approved via the FDA's pre-market approval (PMA) pathway. We conducted a cross-sectional survey of 47 manufacturers with operations in California, Minnesota, and Massachusetts who market devices approved via the PMA pathway. Among 22 respondents (response rate =47%), nearly all self-reported conducting post-market clinical research studies, commonly between 1 and 5; only 1 respondent reported never conducting post-market clinical research studies. While manufacturers most often engaged in these studies to satisfy FDA requirements, other reasons were reported, including performance monitoring and surveillance and market acceptance initiatives. Risks of conducting and not conducting post-market clinical research studies were described through open-ended response to questions. Medical device manufacturers commonly initiate post-market clinical studies at the request of the FDA. Clinical data from these studies should be integrated into national post-market surveillance initiatives.

  11. Toward a treaty on safety and cost-effectiveness of pharmaceuticals and medical devices: enhancing an endangered global public good

    Directory of Open Access Journals (Sweden)

    Faunce Thomas

    2006-03-01

    Full Text Available Abstract • Expert evaluations of the safety, efficacy and cost-effectiveness of pharmaceutical and medical devices, prior to marketing approval or reimbursement listing, collectively represent a globally important public good. The scientific processes involved play a major role in protecting the public from product risks such as unintended or adverse events, sub-standard production and unnecessary burdens on individual and governmental healthcare budgets. • Most States now have an increasing policy interest in this area, though institutional arrangements, particularly in the area of cost-effectiveness analysis of medical devices, are not uniformly advanced and are fragile in the face of opposing multinational industry pressure to recoup investment and maintain profit margins. • This paper examines the possibility, in this context, of States commencing negotiations toward bilateral trade agreement provisions, and ultimately perhaps a multilateral Treaty, on safety, efficacy and cost-effectiveness analysis of pharmaceuticals and medical devices. Such obligations may robustly facilitate a conceptually interlinked, but endangered, global public good, without compromising the capacity of intellectual property laws to facilitate local product innovations.

  12. 78 FR 35940 - Content of Premarket Submissions for Management of Cybersecurity in Medical Devices; Draft...

    Science.gov (United States)

    2013-06-14

    ...] Content of Premarket Submissions for Management of Cybersecurity in Medical Devices; Draft Guidance for... draft guidance entitled ``Content of Premarket Submissions for Management of Cybersecurity in Medical Devices.'' This guidance identifies cybersecurity issues that manufacturers should consider in preparing...

  13. [Twenty-year History and Future Challenges in Transparency Enhancement of Review Process for Approval: Focus on Public Release of Review Reports regarding New Drugs and Medical Devices].

    Science.gov (United States)

    Morimoto, Kazushige; Kawasaki, Satoko; Yoshida, Yasunori

    2015-01-01

    For 20 years, the Ministry of Health, Labour and Welfare (MHLW, formerly Ministry of Health and Welfare (MHW)) has been trying to increase transparency of the review process for approving reports in order to promote the rational use of newly approved drugs and medical devices. The first Summary Basis of Approval (SBA) was published by MHW in 1994. In 1999, evaluation reports were prepared by MHW and the Pharmaceuticals and Medical Devices Evaluation Center to make them available to the public. In 2005, a notice from the Chief Executive of the Pharmaceuticals and Medical Devices Agency (PMDA) made procedures for public release of information on reviewing applications for new drugs. In 2006, 90 review reports of newly approved drugs and eight medical devices were revealed on PMDA websites. The dissemination of information by the United States Food and Drug Administration (FDA) and that of the European Medicines Agency (EMA) were studied and compared with that of the MHLW and PMDA. While common technical documents (CTD) for new drugs and summary technical documents (STED) for new medical devices have been released by PMDA, such documents are not released by the FDA and EMA. The European Public Assessment Report (EAPR) summary for the public is an interesting questionnaire approach that uses the "What," "How" and "Why" format. Finally, future proposals for the next decade are also outlined.

  14. BORDERLINE AND CLASSIFICATION IN THE COMMUNITY REGULATORY FRAMEWORK FOR MEDICAL DEVICES – BRIEF REVIEW ON SOME DENTISTRY PRODUCTS.

    Directory of Open Access Journals (Sweden)

    Maya Lyapina

    2015-02-01

    Full Text Available Defining a given product as a medical device and interpretation of the application of the classification rules fall within the competence of the competent authorities of the Member States where the product is on the market. Different interpretations of Community legislation occur, and, can put public health at risk and distort the internal market. Borderline cases are considered to be those cases where it is not clear from the outset whether a given product is a medical device, an in vitro diagnostic medical device, an active implantable medical device or not. Classification cases can be described as those cases where there exists a difficulty in the uniform application of the classification rules as laid down in the Medical Devices Directive (MDD, or where for a given device, depending on interpretation of the rules, different classifications can occur. The aim of the present work is to make a brief review on discussion on classification in the community regulatory framework for medical devices of some dentistry products.

  15. The Biological Responses to Magnesium-Based Biodegradable Medical Devices

    Directory of Open Access Journals (Sweden)

    Lumei Liu

    2017-11-01

    Full Text Available The biocompatibility of Magnesium-based materials (MBMs is critical to the safety of biodegradable medical devices. As a promising metallic biomaterial for medical devices, the issue of greatest concern is devices’ safety as degrading products are possibly interacting with local tissue during complete degradation. The aim of this review is to summarize the biological responses to MBMs at the cellular/molecular level, including cell adhesion, transportation signaling, immune response, and tissue growth during the complex degradation process. We review the influence of MBMs on gene/protein biosynthesis and expression at the site of implantation, as well as throughout the body. This paper provides a systematic review of the cellular/molecular behavior of local tissue on the response to Mg degradation, which may facilitate a better prediction of long-term degradation and the safe use of magnesium-based implants through metal innovation.

  16. An evaluation of sharp safety blood evacuation devices.

    Science.gov (United States)

    Ford, Joanna; Phillips, Peter

    This article describes an evaluation of three sharp safety blood evacuation devices in seven Welsh NHS boards and the Welsh Blood Service. Products consisted of two phlebotomy needles possessing safety shields and one phlebotomy device with wings, tubing and a retractable needle. The device companies provided the devices and appropriate training. Participating healthcare workers used the safety device instead of the conventional device to sample blood during the evaluation period and each type of device was evaluated in random order. Participants filled in a questionnaire for each type of device and then a further questionnaire comparing the two shielded evacuation needles with each other Results showed that responses to all three products were fairly positive, although each device was not liked by everyone who used it. When the two shielded evacuation devices were compared with each other, most users preferred the device with the shield positioned directly above the needle to the device with the shield at the side. However, in laboratory tests, the preferred device produced more fluid splatter than the other shielded device on activation.

  17. Communication during pediatric asthma visits and child asthma medication device technique 1 month later.

    Science.gov (United States)

    Sleath, Betsy; Carpenter, Delesha M; Ayala, Guadalupe X; Williams, Dennis; Davis, Stephanie; Tudor, Gail; Yeatts, Karin; Gillette, Chris

    2012-11-01

    This study investigated how provider demonstration of and assessment of child use of asthma medication devices and certain aspects of provider-patient communication during medical visits is associated with device technique 1 month later. Two hundred and ninety-six children aged 8-16 years with persistent asthma and their caregivers were recruited at five North Carolina pediatric practices. All of the medical visits were audio-tape recorded. Children were interviewed 1 month later and their device technique was observed and rated. If the provider asked the child to demonstrate metered dose inhaler technique during the medical visit, then the child was significantly more likely to perform a greater percentage of inhaler steps correctly 1 month later. Children with higher asthma management self-efficacy scores were significantly more likely to perform a greater percentage of diskus steps correctly. Additionally, children were significantly more likely to perform a greater percentage of diskus steps correctly if the provider discussed a written action plan during the visit. Children were significantly more likely to perform a greater percentage of turbuhaler steps correctly if they asked more medication questions. Providers should ask children to demonstrate their inhaler technique during medical visits so that they can educate children about proper technique and improve child asthma management self-efficacy. Providers should encourage children to ask questions about asthma medication devices during visits and they should discuss asthma action plans with families.

  18. French Sizing of Medical Devices is not Fit for Purpose

    International Nuclear Information System (INIS)

    Kibriya, Nabil; Hall, Rebecca; Powell, Steven; How, Thien; McWilliams, Richard G.

    2013-01-01

    PurposeThe purpose of the study is to quantify the variation in the metric equivalent of French size in a range of medical devices, from various manufacturers, used in interventional radiology.MethodsThe labelling of a range of catheters, introducers, drains, balloons, stents, and endografts was examined. Products were chosen to achieve a broad range of French sizes from several manufacturers. To assess manufacturing accuracy, eight devices were selected for measurement using a laser micrometer. The external diameters of three specimens of each device were measured at centimeter intervals along the length of the device to ensure uniformity.ResultsA total of 200 labels of interventional radiology equipment were scrutinized. The results demonstrate a wide variation in the metric equivalent of French sizing. Labelled products can vary in diameter across the product range by up to 0.79 mm.The devices selected for measurement with the non-contact laser micrometer demonstrate acceptable manufacturing consistency. The external diameter differed by 0.05 mm on average.ConclusionsOur results demonstrate wide variation in the interpretation of the French scale by different manufacturers of medical devices. This has the potential to lead to problems using coaxial systems especially when the products are from different manufacturers. It is recommended that standard labelling should be employed by all manufacturers conveying specific details of the equipment. Given the wide variation in the interpretation of the French scale, our opinion is that this scale either needs to be abandoned or be strictly defined and followed

  19. 77 FR 38177 - TRICARE; Off-Label Uses of Devices; Partial List of Examples of Unproven Drugs, Devices, Medical...

    Science.gov (United States)

    2012-06-27

    ... drugs, devices, and medical treatments or procedures and adding the TRICARE definition of unlabeled or... labeling. We are now modifying the definition of ``unlabeled or off-label drug'' to ``off-label use of a... reference back to the definition of the term in 199.2. ``Off-label uses of drugs and devices'' includes off...

  20. 75 FR 20854 - Medical Device Use in the Home Environment: Implications for the Safe and Effective Use of...

    Science.gov (United States)

    2010-04-21

    ...] Medical Device Use in the Home Environment: Implications for the Safe and Effective Use of Medical Device... related to the safe and effective use of medical device technology in the home environment. The workshop... the home environment. FDA will solicit feedback on: 1. The agency's current working definition of...

  1. Medical devices and the Middle East: market, regulation, and reimbursement in Gulf Cooperation Council states.

    Science.gov (United States)

    Howard, Jason J

    2014-01-01

    With some of the richest economies in the world, the Gulf Cooperation Council (GCC) is undergoing rapid growth not only in its population but also in health care expenditure. Despite the GCC's abundance of hydrocarbon-based wealth, the drivers of the medical device industry in the GCC are still in flux, with gains yet to be made in areas of infrastructure, regulation, and reimbursement. However, the regional disease burden, expanding health insurance penetration, increasing privatization, and a desire to attract skilled expatriate health care providers have led to favorable conditions for the medical device market in the GCC. The purpose of this article is to investigate the current state of the GCC medical device industry, with respect to market, regulation, and reimbursement, paying special attention to the three largest medical device markets: Saudi Arabia, the United Arab Emirates, and Qatar. The GCC would seem to represent fertile ground for the development of medical technologies, especially those in line with the regional health priorities of the respective member states.

  2. Compiling a Medical Device File and a Proposal for an International Standard for Rehabilitation Robots

    NARCIS (Netherlands)

    Römer, GertWillem R.B.E.; Stuyt, Harry J.A.

    2007-01-01

    Medical devices produced by manufacturers are subject to regulatory review by authorities. Usually, medical devices are developed at universities and other research institutes. This implies that regulatory activities are to be carried out by the designer at these organizations also. And as early as

  3. 78 FR 56719 - Challenging Regulatory and Reimbursement Paradigms for Medical Devices in the Treatment of...

    Science.gov (United States)

    2013-09-13

    ...] Challenging Regulatory and Reimbursement Paradigms for Medical Devices in the Treatment of Metabolic Diseases... announcing a public workshop entitled ``Changing Regulatory and Reimbursement Paradigms for Medical Devices... registration information on the AGA Web site. If you need special accommodations due to a disability, please...

  4. Medical Device Integrated Vital Signs Monitoring Application with Real-Time Clinical Decision Support.

    Science.gov (United States)

    Moqeem, Aasia; Baig, Mirza; Gholamhosseini, Hamid; Mirza, Farhaan; Lindén, Maria

    2018-01-01

    This research involves the design and development of a novel Android smartphone application for real-time vital signs monitoring and decision support. The proposed application integrates market available, wireless and Bluetooth connected medical devices for collecting vital signs. The medical device data collected by the app includes heart rate, oxygen saturation and electrocardiograph (ECG). The collated data is streamed/displayed on the smartphone in real-time. This application was designed by adopting six screens approach (6S) mobile development framework and focused on user-centered approach and considered clinicians-as-a-user. The clinical engagement, consultations, feedback and usability of the application in the everyday practices were considered critical from the initial phase of the design and development. Furthermore, the proposed application is capable to deliver rich clinical decision support in real-time using the integrated medical device data.

  5. The tablet device in hospital neurology and in neurology graduate medical education: a preliminary study.

    Science.gov (United States)

    George, Pravin; Newey, Christopher R; Bhimraj, Adarsh

    2015-01-01

    There is limited literature on tablet devices for neurohospitalists and in neurological graduate medical education. This study evaluated utilization, benefits, and limitations of customized tablets on inpatient neurology practice and resident education. The hypothesis was the perception of the tablet would be positive, given their portability, convenience to accessing point-of-care reference, and accessibility to the electronic medical record. Second-generation iPads with neurology-specific applications and literature were provided to our in-hospital general, stroke, and consult neurology teams. After 1 year, residents on these teams were surveyed on demographic data, familiarity, and utilization of the iPad and their perceptions of the device. All 27 residents responded to the survey. Most participants (23 of 27) used a tablet while on inpatient service. Twelve regularly utilized the neurology-specific apps and/or accessed scientific articles. Technologically savvy residents felt significantly more comfortable using tablets and were more quickly acquainted with the features. Thirteen respondents wanted a formal orientation on the advanced features of the tablet independent of their familiarity with the device or level of technological comfort. Overall, the perception was that the tablet was beneficial for inpatient clinical care and as an educational reference. Participants became easily familiarized with the device features quickly, regardless of whether they owned one previously or not. Most physicians indicated interest in advanced features of tablets; however, a formal orientation may be beneficial for optimal utilization. A reliable network connection is essential to in-hospital use of tablet devices. Additional research pertaining to patient outcomes, objective educational benefit, and cost-effectiveness is necessary.

  6. Radiation as a microbiological contamination control of drugs, cosmetics and medical devices

    International Nuclear Information System (INIS)

    Ishizeki, Chuichi

    1985-01-01

    This paper deals with current status of radiation sterilization or disinfection of drugs, cosmetics, their materials, and medical devices, and with quality control as a tool for securing microbiological safety, especially current status of sterilization tests. Ointment containing tetracyclin, steroid hormones, gelatin, and enzymes are presented as drug samples to be irradiated, and explanations for radiation sterilization of these drugs are provided. An outline of the application of radiation in cosmetics and medical devices is given. Issues are also provided from the viewpoint of safey and effectiveness of radiation sterilization. (Namekawa, K.)

  7. Limited Awareness of the Essences of Certification or Compliance Markings on Medical Devices.

    Science.gov (United States)

    Foo, Jong Yong Abdiel; Tan, Xin Ji Alan

    2017-06-01

    Medical devices have been long used for odiagnostic, therapeutic or rehabilitation purposes. Currently, they can range from a low-cost portable device that is often used for personal health monitoring to high-end sophisticated equipment that can only be operated by trained professionals. Depending on the functional purposes, there are different certification or compliance markings on the device when it is sold. One common certification marking is the Conformité Européenne affixation but this has a range of certification mark numbering for a variety of functional purposes. While the regulators and medical device manufacturers understand the associated significance and clinical implications, these may not be apparent to the professionals (using or maintaining the device) and the general public. With portable healthcare devices and mobile applications gaining popularity, better awareness of certification marking will be needed. Particularly, there are differences in the allowed functional purposes and the associated cost derivations of devices with a seemingly similar nature. A preferred approach such as an easy-to-understand notation next to any certification marking on a device can aid in differentiation without the need to digest mountainous regulatory details.

  8. Feasibility of energy harvesting techniques for wearable medical devices.

    Science.gov (United States)

    Voss, Thaddaeus J; Subbian, Vignesh; Beyette, Fred R

    2014-01-01

    Wearable devices are arguably one of the most rapidly growing technologies in the computing and health care industry. These systems provide improved means of monitoring health status of humans in real-time. In order to cope with continuous sensing and transmission of biological and health status data, it is desirable to move towards energy autonomous systems that can charge batteries using passive, ambient energy. This not only ensures uninterrupted data capturing, but could also eliminate the need to frequently remove, replace, and recharge batteries. To this end, energy harvesting is a promising area that can lead to extremely power-efficient portable medical devices. This paper presents an experimental prototype to study the feasibility of harvesting two energy sources, solar and thermoelectric energy, in the context of wearable devices. Preliminary results show that such devices can be powered by transducing ambient energy that constantly surrounds us.

  9. Dosimetric studies for gamma radiation validation of medical devices

    International Nuclear Information System (INIS)

    Soliman, Y.S.; Beshir, W.B.; Abdel-Fattah, A.A.; Abdel-Rehim, F.

    2013-01-01

    The delivery and validation of a specified dose to medical devices are key concerns to operators of gamma radiation facilities. The objective of the present study was to characterize the industrial gamma radiation facility and map the dose distribution inside the product-loading pattern during the validation and routine control of the sterilization process using radiochromic films. Cardboard phantoms were designed to achieve the homogeneity of absorbed doses. The uncertainty of the dose delivered during validation of the sterilization process was assessed. - Highlights: ► Using γ-rays for sterilization of hollow fiber dialyzers and blood tubing sets according to ISO 11137, 2006. ► Dosimetry studies of validations of γ-irradiation facility and sterilized medical devices. ► Places of D min and D max have been determined using FWT-60 films. ► Determining the target minimum doses required to meet the desired SAL of 10 −6 for the two products.

  10. Grave fraudulence in medical device research: a narrative review of the PIN seeding study for the Pinnacle hip system.

    Science.gov (United States)

    Steffen, Joan E; Fassler, Ella A; Reardon, Kevin J; Egilman, David S

    2018-01-01

    In 2001, DePuy, a wholly-owned subsidiary of Johnson & Johnson (J&J/DePuy), initiated a seeding study called the "Multi-center, Prospective, Clinical Evaluation of Pinnacle Acetabular Implants in Total Hip Arthroplasty" (PIN Study). J&J/DePuy designed this study to develop new business opportunities during the launch of their Pinnacle Hip System (PHS) and generate survivorship data for marketing. This article, the first review of a seeding trial for a medical device, examines internal company documents relating to the PIN Study; the analysis herein focuses on the integrity of J&J/DePuy's research practices in conception, implementation, and analysis. J&J/DePuy violated the study protocol and manipulated data; consented participants in violation of standards protecting human subjects; and did not secure Institutional Review Board approval for all study sites. J&J/DePuy used PIN Study results as the "fundamental selling point" for the PHS. Medical device seeding trials are distinct from previously-documented pharmaceutical seeding trials because companies can profit directly from device sales and because these studies may be the first clinical evaluation of the device (as was the case for the PIN Study). Seeding trials are malleable marketing projects, not rigorous scientific studies. Regulatory bodies, physicians, and others should be vigilant for persuasive marketing accounts disguised as science.

  11. Field Safety Notes in Product Problems of Medical Devices for Use in Pulmonology.

    Science.gov (United States)

    Hannig, Jürgen; Siekmeier, Rüdiger

    2015-01-01

    The current European system for medical devices is governed by three EC directives: the Medical Device Directive 93/42/EEC, the In-Vitro Diagnostic Directive 98/79/EC and the Active Implantable Medical Device Directive 90/385/EEC and regulates marketing and post-market surveillance of medical devices in the European Economic Area. In cases of incidents and field safety corrective actions (FSCA) manufacturers have to inform the responsible Competent Authority, which is the Federal Institute for Drugs and Medical Devices (BfArM) and the public by field safety notices (FSN). In this study we analyzed FSN of medical devices exclusively serving for diagnostics or treatment in pulmonology (e.g. nebulizers, oxygen concentrators, pulse oximeters, lung function analyzers, and non-active devices for treatment). FSCA and FSN publicized by BfArM in 2005-2013 were analyzed in respect to the MEDDEV 2.12-1 rev 8. In total 41 FSCA were publicized for the included products. German and English FSN were found in 36/35 cases, respectively. FSN were clearly characterized as FSN in 22/20 cases and declaration of the type of action was found in 27/26 cases, respectively. Product names were provided in all cases. Lot numbers or other information for product characterization were available in 7/8 and 26/24 cases, respectively. Detailed information regarding FSCA and product malfunction were found in 27/33 and 36/35 cases, respectively. Information on product related risks with previous use of the affected product was provided in 24/23 cases. In 34/34 cases manufacturers provided information to mitigate product related risks. Requests to pass FSN to persons needing awareness were found in 10/14 cases. Contact data were provided in 30/30 cases. Confirmation that the Competent Authority was informed was found in 12/14 cases and in 19/18 cases a customer confirmation was included. The obtained data suggest that there is an increasing annual number of FSCA and most FSN fulfill the criteria of

  12. Evaluation of a muscle pump-activating device for non-healing venous leg ulcers.

    Science.gov (United States)

    Harris, Connie; Duong, Rochelle; Vanderheyden, Gwen; Byrnes, Beth; Cattryse, Renee; Orr, Ava; Keast, David

    2017-12-01

    This evaluation involves an innovative muscle pump-activating device (geko™) as an adjunctive therapy with best practices for non-healing venous leg ulcers (VLUs). Stimulating the common peroneal nerve (at the fibular head), the geko™ device creates a response that acts as foot and calf muscle pumps, increasing venous, arterial and microcirculatory flow. The aim was to evaluate and determine if the geko™ is effective in this population and if it should be added to the medical supply formulary. In all, 12 patients with 18 recalcitrant VLUs (defined as less than 30% reduction in wound size in 30 days with best practices) in two community settings in Ontario consented to the evaluation and were treated with the geko™ for up to 20 weeks. A total of 44% of wounds healed, and 39% decreased in size. One patient non-adherent with the geko™ and best practices had deterioration in his or her wounds. With the patients as their own control, the mean weekly healing rate with the geko™ was 9·35% (±SD 0·10) compared to 0·06% (±SD 0·10) prior to baseline, which was statistically significant (P devices in 7 of 12 (58%) patients. One patient stopped the device due to rash, while another had to take breaks from using the device. Subsequently, the manufacturer (FirstKind Ltd) has developed a new device and protocol specific to the requirements of wound therapy to minimise this response. This small case series demonstrated the highly significant effectiveness of the geko™ device in these hard-to-heal VLUs. Further evaluations to determine dose and patient selection criteria are underway. © 2017 The Authors. International Wound Journal published by Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  13. Fiber-optic Fourier transform infrared spectroscopy for remote label-free sensing of medical device surface contamination

    Science.gov (United States)

    Hassan, Moinuddin; Tan, Xin; Welle, Elissa; Ilev, Ilko

    2013-05-01

    As a potential major source of biochemical contamination, medical device surfaces are of critical safety concerns in the clinical practice and public health. The development of innovative sensing methods for accurate and real-time detection of medical device surface contamination is essential to protect patients from high risk infection. In this paper, we demonstrate an alternative fiber-optic Fourier Transform Infrared (FTIR) spectroscopy based sensing approach for remote, non-contact, and label-free detection of biochemical contaminants in the mid-infrared (mid-IR) region. The sensing probe is designed using mid-IR hollow fibers and FTIR measurements are carried out in reflection mode. Bovine Serum Albumin (BSA) and bacterial endotoxin of different concentrations under thoroughly dry condition are used to evaluate the detection sensitivity. The devised system can identify ≤0.0025% (≤4 × 1011 molecules) BSA and 0.5% (0.5 EU/ml) endotoxin concentration. The developed sensing approach may be applied to detect various pathogens that pose public health threats.

  14. BioInnovate Ireland--fostering entrepreneurial activity through medical device innovation training.

    Science.gov (United States)

    Bruzzi, M S; Linehan, J H

    2013-09-01

    In the midst of a rich environment for medical device development and manufacturing, universities can play a critical role by developing relevant training programs to produce entrepreneurs who can be efficient and successful in creating early stage companies by understanding deeply the issues involved in creating a useful device, how to raise money, designing early clinical studies and locating manufacturing partners.

  15. Usability evaluation of a locomotor therapy device considering different strategies

    Directory of Open Access Journals (Sweden)

    Langthaler Sonja

    2016-09-01

    Full Text Available Usability of medical devices is one of the main determining factors in preventing use errors in treatment and strongly correlates to patient safety and quality of treatment. This thesis demonstrates the usability testing and evaluation of a prototype for locomotor therapy of infants. Therefore, based on the normative requirements of the EN 62366, a concept combined of evaluation procedures and assessing methods was created to enable extensive testing and analysis of the different aspects of usability. On the basis of gathered information weak points were identified and appropriate measures were presented to increase the usability and operating safety of the locomotor prototype. The overall outcome showed an usability value of 77.4% and an evaluation score of 6.99, which can be interpreted as “satisfactory”.

  16. Hacking medical devices a review - biomed 2013.

    Science.gov (United States)

    Frenger, Paul

    2013-01-01

    Programmable, implantable and external biomedical devices (such as pacemakers, defibrillators, insulin pumps, pain management pumps, vagus nerve stimulators and others) may be vulnerable to unauthorized access, commonly referred to as “hacking”. This intrusion may lead to compromise of confidential patient data or loss of control of the device itself, which may be deadly. Risks to health from unauthorized access is in addition to hazards from faulty (“buggy”) software or circuitry. Historically, this aspect of medical device design has been underemphasized by both manufacturers and regulatory bodies until recently. However, an insulin pump was employed as a murder weapon in 2001 and successful hacking of an implantable defibrillator was demonstrated in 2008. To remedy these problems, professional groups have announced a variety of design standards and the governmental agencies of several countries have enacted device regulations. In turn, manufacturers have developed new software products and hardware circuits to assist biomedical engineering firms to improve their commercial offerings. In this paper the author discusses these issues, reviewing known problems and zero-day threats, with potential solutions. He outlines his approach to secure software and hardware challenges using the Forth language. A plausible scenario is described in which hacking of an implantable defibrillator by terrorists results in a severe national security threat to the United States.

  17. Monitoring of biofilm formation on different material surfaces of medical devices using hyperspectral imaging method

    Science.gov (United States)

    Kim, Do-Hyun; Kim, Moon S.; Hwang, Jeeseong

    2012-03-01

    Contamination of the inner surface of indwelling (implanted) medical devices by microbial biofilm is a serious problem. Some microbial bacteria such as Escherichia coli form biofilms that lead to potentially lifethreatening infections. Other types of medical devices such as bronchoscopes and duodenoscopes account for the highest number of reported endoscopic infections where microbial biofilm is one of the major causes for these infections. We applied a hyperspectral imaging method to detect biofilm contamination on the surface of several common materials used for medical devices. Such materials include stainless steel, titanium, and stainless-steeltitanium alloy. Potential uses of hyperspectral imaging technique to monitor biofilm attachment to different material surfaces are discussed.

  18. On a turbulent wall model to predict hemolysis numerically in medical devices

    Science.gov (United States)

    Lee, Seunghun; Chang, Minwook; Kang, Seongwon; Hur, Nahmkeon; Kim, Wonjung

    2017-11-01

    Analyzing degradation of red blood cells is very important for medical devices with blood flows. The blood shear stress has been recognized as the most dominant factor for hemolysis in medical devices. Compared to laminar flows, turbulent flows have higher shear stress values in the regions near the wall. In case of predicting hemolysis numerically, this phenomenon can require a very fine mesh and large computational resources. In order to resolve this issue, the purpose of this study is to develop a turbulent wall model to predict the hemolysis more efficiently. In order to decrease the numerical error of hemolysis prediction in a coarse grid resolution, we divided the computational domain into two regions and applied different approaches to each region. In the near-wall region with a steep velocity gradient, an analytic approach using modeled velocity profile is applied to reduce a numerical error to allow a coarse grid resolution. We adopt the Van Driest law as a model for the mean velocity profile. In a region far from the wall, a regular numerical discretization is applied. The proposed turbulent wall model is evaluated for a few turbulent flows inside a cannula and centrifugal pumps. The results present that the proposed turbulent wall model for hemolysis improves the computational efficiency significantly for engineering applications. Corresponding author.

  19. State of the art of medical devices featuring smart electro-rheological and magneto-rheological fluids

    Directory of Open Access Journals (Sweden)

    Jong-Seok Oh

    2017-10-01

    Full Text Available Recently, smart fluids have drawn significant attention and growing a great interest in a broad range of engineering applications such as automotive and medical areas. In this article, two smart fluids called electro-rheological (ER fluid and magneto-rheological (MR fluid are reviewed in terms of medical applications. Especially, this article describes the attributes and inherent properties of individual medical and rehabilitation devices. The devices surveyed in this article include multi-degree-of-freedom haptic masters for robot surgery, thin membrane touch panels for braille readers, sponge-like tactile sensors to feel human tissues such as liver, rehabilitation systems such as prosthetic leg, and haptic interfaces for dental implant surgery. The operating principle, inherent characteristics and practical feasibility of each medical device or system are fully discussed in details.

  20. Practical design control implementation for medical devices

    CERN Document Server

    Justiniano, Jose

    2003-01-01

    Bringing together the concepts of design control and reliability engineering, this book is a must for medical device manufacturers. It helps them meet the challenge of designing and developing products that meet or exceed customer expectations and also meet regulatory requirements. Part One covers motivation for design control and validation, design control requirements, process validation and design transfer, quality system for design control, and measuring design control program effectiveness. Part Two discusses risk analysis and FMEA, designing-in reliability, reliability and design verific

  1. [The roles and the impacts of pharmacists in the management of medical devices at the hospital: A literature review].

    Science.gov (United States)

    Ferrand, É; Painchart, L; Grimandi, G; Décaudin, B; Bussières, J-F

    2017-11-01

    Identify the training profile and the published evidences about the roles and the impacts of hospital pharmacists in medical devices. A literature review was conducted using Google, Google Scholar and Pubmed for 1990-2016 associated with a manual search conducted in three non-indexed pharmaceutical journals for 2000-2016. The analysis of training programs available did not allow us to identify a specific training profile. A total of 72 articles related to the roles and the impacts of the pharmacist were identified, 52 of which came from non-indexed journals. Those articles did not deal specifically about the roles and the impacts of pharmacist; however, articles were analyses for three spheres including the referencing of medical devices (n=36), the evaluation (n=19) and the distribution system (n=13). French pharmacists have many theoretical and practical training opportunities. There are a few articles describing precisely the roles and the impacts of hospital pharmacists in medical device. It appears urgent to better document this activity in professional and indexed literature. Copyright © 2017 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.

  2. Medical Device Plug-and-Play Interoperability Standards and Technology Leadership

    Science.gov (United States)

    2016-10-01

    death,” The Boston Globe, April 3 2010. 27. Arney D, Pajic M, Goldman JM, Lee I, Mangharam R, Sokolsky O, “Toward Patient Safety in Closed - Loop Medical ...becoming increasingly clear. We have been providing medical device interoperability domain expertise to assist the Veterans Administration in a...15. Wallroth C, Goldman J, Manigel J, Osborn D, Roellike T, Weininger S, Westenskow D, “Development of a Standard for Physiologic Closed Loop

  3. Remote Access: A Vision for Mobile Medical Devices

    Directory of Open Access Journals (Sweden)

    Herbert Ernst

    2005-11-01

    Full Text Available During the Symposium for Remote Engineering and Virtual Instrumentation held at Brasov in early July 2005 an outlook was presented regarding the future potential of remote engineering for mobile medical devices. It is the intention of this article to recapitulate the content of the initiated discussions and to stimulate work in this complex and until now largely neglected field of application.

  4. How does the knowledge environment shape procurement practices for orthopaedic medical devices in Mexico?

    Science.gov (United States)

    Lingg, Myriam; Wyss, Kaspar; Durán-Arenas, Luis

    2016-07-08

    In organisational theory there is an assumption that knowledge is used effectively in healthcare systems that perform well. Actors in healthcare systems focus on managing knowledge of clinical processes like, for example, clinical decision-making to improve patient care. We know little about connecting that knowledge to administrative processes like high-risk medical device procurement. We analysed knowledge-related factors that influence procurement and clinical procedures for orthopaedic medical devices in Mexico. We based our qualitative study on 48 semi-structured interviews with various stakeholders in Mexico: orthopaedic specialists, government officials, and social security system managers or administrators. We took a knowledge-management related perspective (i) to analyse factors of managing knowledge of clinical procedures, (ii) to assess the role of this knowledge and in relation to procurement of orthopaedic medical devices, and (iii) to determine how to improve the situation. The results of this study are primarily relevant for Mexico but may also give impulsion to other health systems with highly standardized procurement practices. We found that knowledge of clinical procedures in orthopaedics is generated inconsistently and not always efficiently managed. Its support for procuring orthopaedic medical devices is insufficient. Identified deficiencies: leaders who lack guidance and direction and thus use knowledge poorly; failure to share knowledge; insufficiently defined formal structures and processes for collecting information and making it available to actors of health system; lack of strategies to benefit from synergies created by information and knowledge exchange. Many factors are related directly or indirectly to technological aspects, which are insufficiently developed. The content of this manuscript is novel as it analyses knowledge-related factors that influence procurement of orthopaedic medical devices in Mexico. Based on our results we

  5. 21 CFR 801.125 - Medical devices for use in teaching, law enforcement, research, and analysis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical devices for use in teaching, law enforcement, research, and analysis. 801.125 Section 801.125 Food and Drugs FOOD AND DRUG ADMINISTRATION... Directions for Use § 801.125 Medical devices for use in teaching, law enforcement, research, and analysis. A...

  6. [Radiotherapy and implantable medical device: example of infusion pumps].

    Science.gov (United States)

    Abrous-Anane, S; Benhassine, S; Lopez, S; Cristina, K; Mazeron, J-J

    2013-12-01

    Indication for radiotherapy is often questioned for patients equipped with implantable medical devices like infusion pumps as the radiation tolerance is poor or not known. We report here on the case of a patient who we treated with pelvic radiotherapy for cervical cancer and who had an infusion pump in iliac fossa. We conducted a series of tests on five identical pumps that insured that the treatment protocol is harmless to the implanted device. Copyright © 2013 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  7. A prospective window into medical device-related pressure ulcers in intensive care.

    Science.gov (United States)

    Coyer, Fiona M; Stotts, Nancy A; Blackman, Virginia Schmied

    2014-12-01

    The aim of this study was to determine the prevalence, severity, location, aetiology, treatment and healing of medical device-related pressure ulcers (PUs) in intensive care patients for up to 7 days. A prospective repeated measures study design was used. Patients in six intensive care units of two major medical centres, one each in Australia and the USA, were screened 1 day per month for 6 months. Those with device-related ulcers were followed daily for up to 7 days. The outcome measures were device-related ulcer prevalence, pain, infection, treatment and healing. Fifteen of 483 patients had device-related ulcers and 9 of 15 with 11 ulcers were followed beyond screening. Their mean age was 60·5 years, and most were men, overweight and at increased risk of PU. Endotracheal (ET) and nasogastric (NG) tubes were the cause of most device-related ulcers. Repositioning was the most frequent treatment. Four of 11 ulcers healed within the 7-day observation period. In conclusion, device-related ulcer prevalence was 3·1%, similar to that reported in the limited literature available, indicating an ongoing problem. Systematic assessment and repositioning of devices are the mainstays of care. We recommend continued prevalence determination and that nurses remain vigilant to prevent device-related ulcers, especially in patients with NG and ET tubes. © 2013 The Authors. International Wound Journal © 2013 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  8. Evaluating interactive computer-based scenarios designed for learning medical technology.

    Science.gov (United States)

    Persson, Johanna; Dalholm, Elisabeth Hornyánszky; Wallergård, Mattias; Johansson, Gerd

    2014-11-01

    The use of medical equipment is growing in healthcare, resulting in an increased need for resources to educate users in how to manage the various devices. Learning the practical operation of a device is one thing, but learning how to work with the device in the actual clinical context is more challenging. This paper presents a computer-based simulation prototype for learning medical technology in the context of critical care. Properties from simulation and computer games have been adopted to create a visualization-based, interactive and contextually bound tool for learning. A participatory design process, including three researchers and three practitioners from a clinic for infectious diseases, was adopted to adjust the form and content of the prototype to the needs of the clinical practice and to create a situated learning experience. An evaluation with 18 practitioners showed that practitioners were positive to this type of tool for learning and that it served as a good platform for eliciting and sharing knowledge. Our conclusion is that this type of tools can be a complement to traditional learning resources to situate the learning in a context without requiring advanced technology or being resource-demanding. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Biofilm eradication and prevention: a pharmaceutical approach to medical device infections

    National Research Council Canada - National Science Library

    Shunmugaperumal, Tamilvanan

    2010-01-01

    "Biofilm Eradication and Preventions presents the basics of biofilm formation on medical devices, diseases related to this formation, and approaches pharmaceutical researchers need to take to limit this problem...

  10. Evaluation of stray radiofrequency radiation emitted by electrosurgical devices

    International Nuclear Information System (INIS)

    De Marco, M; Maggi, S

    2006-01-01

    Electrosurgery refers to the passage of a high-frequency, high-voltage electrical current through the body to achieve the desired surgical effects. At the same time, these procedures are accompanied by a general increase of the electromagnetic field in an operating room that may expose both patients and personnel to relatively high levels of radiofrequency radiation. In the first part of this study, we have taken into account the radiation emitted by different monopolar electrosurgical devices, evaluating the electromagnetic field strength delivered by an electrosurgical handle and straying from units and other electrosurgical accessories. As a summary, in the worst case a surgeon's hands are exposed to a continuous and pulsed RF wave whose magnetic field strength is 0.75 A m -1 (E-field 400 V m -1 ). Occasionally stray radiation may exceed ICNIRP's occupational exposure guidelines, especially close to the patient return plate. In the second part of this paper, we have analysed areas of particular concern to prevent electromagnetic interference with some life-support devices (ventilators and electrocardiographic devices), which have failed to operate correctly. Most clinically relevant interference occurred when an electrosurgery device was used within 0.3 m of medical equipment. In the appendix, we suggest some practical recommendations intended to minimize the potential for electromagnetic hazards due to therapeutic application of RF energy

  11. Commercial viability of medical devices using Headroom and return on investment calculation

    NARCIS (Netherlands)

    Markiewicz, Katarzyna; van Til, Janine Astrid; Steuten, Lotte Maria Gertruda; IJzerman, Maarten Joost

    2016-01-01

    The market success of a medical product depends on its commercial viability, yet this may be hard to predict during the development process of medical devices. This paper aims to determine if applying the Headroom method combined with return on investment (ROI) analysis allows for estimation of the

  12. 76 FR 34845 - Medical Devices; Ear, Nose, and Throat Devices; Classification of the Wireless Air-Conduction...

    Science.gov (United States)

    2011-06-15

    ... control by other users with a similar medical device. Exposure to non-ionizing radiation Wireless... relating to EMC and wireless technology and human exposure to non-ionizing radiation. Therefore, on March... electro magnetic compatibility (EMC) and safety of exposure to non-ionizing radiation; (2) Design...

  13. Closed-loop approach for situation awareness of medical devices and operating room infrastructure

    Directory of Open Access Journals (Sweden)

    Rockstroh Max

    2015-09-01

    Full Text Available In recent years, approaches for information and control integration in the digital operating room have emerged. A major step towards an intelligent operating room and a cooperative technical environment would be autonomous adaptation of medical devices and systems to the surgical workflow. The OR staff should be freed from information seeking and maintenance tasks. We propose a closed-loop concept integrating workflow monitoring, processing and (semi-automatic interaction to bridge the gap between OR integration of medical devices and workflow-related information management.

  14. Incorporation of stochastic engineering models as prior information in Bayesian medical device trials.

    Science.gov (United States)

    Haddad, Tarek; Himes, Adam; Thompson, Laura; Irony, Telba; Nair, Rajesh

    2017-01-01

    Evaluation of medical devices via clinical trial is often a necessary step in the process of bringing a new product to market. In recent years, device manufacturers are increasingly using stochastic engineering models during the product development process. These models have the capability to simulate virtual patient outcomes. This article presents a novel method based on the power prior for augmenting a clinical trial using virtual patient data. To properly inform clinical evaluation, the virtual patient model must simulate the clinical outcome of interest, incorporating patient variability, as well as the uncertainty in the engineering model and in its input parameters. The number of virtual patients is controlled by a discount function which uses the similarity between modeled and observed data. This method is illustrated by a case study of cardiac lead fracture. Different discount functions are used to cover a wide range of scenarios in which the type I error rates and power vary for the same number of enrolled patients. Incorporation of engineering models as prior knowledge in a Bayesian clinical trial design can provide benefits of decreased sample size and trial length while still controlling type I error rate and power.

  15. Mobile Devices, Learning and Clinical Workplaces: Medical Student Use of Smartphones in Parisian Hospitals

    Science.gov (United States)

    Phelps, Megan; Scott, Karen M.; Chauffeté-Manillier, Martine; Lenne, Frédéric; Le Jeunne, Claire

    2017-01-01

    Mobile devices are ubiquitous worldwide, including in hospitals. "Just in time" learning provided by these devices is important for students. We investigated current use of, and learning with, smartphones and other mobile devices by medical students in Parisian hospitals. A survey with quantitative and qualitative items previously used…

  16. Microbiological Load Of Ethylene Oxide Sterilized Medical Devices And Its Elimination By Cobalt 60 Source

    International Nuclear Information System (INIS)

    Bashir, R.; Afroze, B.; Zulfiqar, H. F.; Saleem, R.; Saleem, F.; Aslam, F.; Naz, S.

    2016-01-01

    Objective: To determine the residing microbial flora of ethylene oxide (EtO) sterilized medical devices and optimization of safe dose of gamma radiation (Cobalt 60 source) for the complete elimination of microbial load. Study Design: Experimental study. Place and Duration of Study: Department of Biotechnology, Lahore College for Women University, Lahore, Pakistan from September 2014 to June 2015. Methodology: Thirty-six samples of EtO sterilized medical devices of same batch of three different companies were collected for this study. Isolation and enumeration of microbes were done by using different selective and differential media. Gram staining and biochemically characterization by API 20 (Bio Merieux, France) kit was done for identification of the microorganisms. The medical devices having high microbial load were sent to Pakistan Radiation Services (PARAS) for gamma irradiations at 3 different selected doses (20 KGy, 25 KGy, and 30 KGy). Result: Different types of Gram positive bacteria (Staphylococcus epidermidis, Staphylococcus aureus and Bacillus subtilis) were isolated from the EtO sterilized samples. Gram negative bacteria and fungi were not detected on these medical devices. Gamma irradiations Result showed that 30 KGy was optimized dose for complete elimination of microbial flora on endotracheal, Nelaton, and tracheostomy tubes. Conclusion: Gamma radiations (Co 60 source) effectively decontaminate the microbial flora on the equipment previously sterilized by the ethylene oxide gas; and 30 KGy is the optimized dose for all these medical devices. (author)

  17. Characterization of Bacterial Etiologic Agents of Biofilm Formation in Medical Devices in Critical Care Setup

    Directory of Open Access Journals (Sweden)

    Sangita Revdiwala

    2012-01-01

    Full Text Available Background. Biofilms contaminate catheters, ventilators, and medical implants; they act as a source of disease for humans, animals, and plants. Aim. Critical care units of any healthcare institute follow various interventional strategies with use of medical devices for the management of critical cases. Bacteria contaminate medical devices and form biofilms. Material and Methods. The study was carried out on 100 positive bacteriological cultures of medical devices which were inserted in hospitalized patients. The bacterial isolates were processed as per microtitre plate. All the isolates were subjected to antibiotic susceptibility testing by VITEK 2 compact automated systems. Results. Out of the total 100 bacterial isolates tested, 88 of them were biofilm formers. A 16–20-hour incubation period was found to be optimum for biofilm development. 85% isolates were multidrug resistants and different mechanisms of bacterial drug resistance like ESBL, carbapenemase, and MRSA were found among isolates. Conclusion. Availability of nutrition in the form of glucose enhances the biofilm formation by bacteria. Time and availability of glucose are important factors for assessment of biofilm progress. It is an alarm for those who are associated with invasive procedures and indwelling medical devices especially in patients with low immunity.

  18. Medical and welfare device session. Toward medical treatment and welfare of tomorrow; Iryo fukushi kiki session. Ashita no iryo fukushi ni mukete

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-09-01

    This paper is the material distributed in the medical and welfare device session held under the auspices of NEDO in September 2000. Diversification of needs in the medical and welfare areas and handling of age advancement are the growing issue. NEDO is putting efforts toward enhancement of quality of life (QOL) and realization of the nation with great life by providing high-quality and high-efficiency medical and welfare services. The NEDO's efforts cover the areas of treating adult diseases such as cancers and cardiac diseases whose seriousness is growing, early diagnoses of diseases, medical treatment with low invasion, elderly people helping, reduction of helpers' burden, reduction of handicaps to elderly people and mentally and physically handicapped persons, and assistance to participation in the society. To achieve these goals, NEDO is implementing the following four projects: research and development of medical and welfare device technologies, researches of medical science and engineering collaboration type, and promotion of developing welfare techno-systems and practical application of welfare appliances. Developments are being made toward practical application of medical and welfare devices with excellent safety and convenience, of low cost and high performance. The session gave the keynote addresses related to medical treatment and prevention of brain diseases; brain, the universe and MRI (the world of mind as seen in images), and high-tech medical treatments to protect brain (challenge to brain that starts now). (NEDO)

  19. Using an Elastic Band Device After a Severe Obstetric Pubic Symphyseal Separation: Clinical and Imaging Evaluation.

    Science.gov (United States)

    Lasbleiz, Jeremy; Sevestre, François-Xavier; Moquet, Pierre-Yves

    2017-09-01

    Severe separation of the pubic symphysis is a rare delivery complication. Facing this pathology, we decided to study a new elastic band device. To evaluate the elastic band device, clinical (pain-rated) and imaging (magnetic resonance imaging and radiography) evaluations with and without the device were performed. The elastic band device is a European Conformity-certified medical device, which is made of neoprene straps, that reduces the mobility of the pelvis and the use of the internal rotator muscles. Once the elastic band device was in place, on postpartum day 1, radiography showed a decrease of the pubic width from 41 to 12 mm. Furthermore, pain decreased from 10 of 10 to 2 of 10 in 2 days, allowing the patient to ambulate and avoid surgery. After 1 month, the pubic width (6 mm) and anatomy were recovered but minor pain was still present with hip rotatory movements. The elastic band device was worn 24 hours a day from postpartum days 1-90 and 12 hours a day from postpartum days 90 to 150; afterward, the patient returned to normal life without the elastic band device. Use of an elastic band device was associated with a reduction of the pubic width and pain associated after obstetric pubic symphysis separation.

  20. Analysis of liquid medication dose errors made by patients and caregivers using alternative measuring devices.

    Science.gov (United States)

    Ryu, Gyeong Suk; Lee, Yu Jeung

    2012-01-01

    Patients use several types of devices to measure liquid medication. Using a criterion ranging from a 10% to 40% variation from a target 5 mL for a teaspoon dose, previous studies have found that a considerable proportion of patients or caregivers make errors when dosing liquid medication with measuring devices. To determine the rate and magnitude of liquid medication dose errors that occur with patient/caregiver use of various measuring devices in a community pharmacy. Liquid medication measurements by patients or caregivers were observed in a convenience sample of community pharmacy patrons in Korea during a 2-week period in March 2011. Participants included all patients or caregivers (N = 300) who came to the pharmacy to buy over-the-counter liquid medication or to have a liquid medication prescription filled during the study period. The participants were instructed by an investigator who was also a pharmacist to select their preferred measuring devices from 6 alternatives (etched-calibration dosing cup, printed-calibration dosing cup, dosing spoon, syringe, dispensing bottle, or spoon with a bottle adapter) and measure a 5 mL dose of Coben (chlorpheniramine maleate/phenylephrine HCl, Daewoo Pharm. Co., Ltd) syrup using the device of their choice. The investigator used an ISOLAB graduated cylinder (Germany, blue grad, 10 mL) to measure the amount of syrup dispensed by the study participants. Participant characteristics were recorded including gender, age, education level, and relationship to the person for whom the medication was intended. Of the 300 participants, 257 (85.7%) were female; 286 (95.3%) had at least a high school education; and 282 (94.0%) were caregivers (parent or grandparent) for the patient. The mean (SD) measured dose was 4.949 (0.378) mL for the 300 participants. In analysis of variance of the 6 measuring devices, the greatest difference from the 5 mL target was a mean 5.552 mL for 17 subjects who used the regular (etched) dosing cup and 4

  1. Biomaterials in medical devices: an interview with Jörg Vienken of Fresenius Medical Care, Germany.

    Science.gov (United States)

    Vienken, Jörg

    2012-06-01

    Biomaterial and biopolymer research have significant impact on the development as well as application of biotechnology. Biotechnology Journal recently attended the "Nanomaterials for Biomedical Technologies 2012" conference. We were privileged to have the opportunity to ask Prof. Dr. Jörg Vienken, VP of BioSciences at Fresenius Medical Care, a few questions relating to medical devices, the importance of publishing for industry, and also his advice for young scientists/engineers looking for a career in industry. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Proposed changes to the reimbursement of pharmaceuticals and medical devices in Poland and their impact on market access and the pharmaceutical industry

    Science.gov (United States)

    Badora, Karolina; Caban, Aleksandra; Rémuzat, Cécile; Dussart, Claude; Toumi, Mondher

    2017-01-01

    ABSTRACT In Poland, two proposed amendments to the reimbursement act are currently in preparation; these are likely to substantially change the pricing and reimbursement landscape for both drugs and medical devices. Proposed changes include: alignment of medical device reimbursement with that of pharmaceuticals; relaxing the strict reimbursement criteria for ultra-orphan drugs; establishment of an additional funding category for vaccines; introduction of compassionate use, and a simplified reimbursement pathway for well-established off-label indications; appreciation of manufacturers’ innovation and research and development efforts by creating a dedicated innovation budget; introduction of a mechanism preventing excessive parallel import; prolonged duration of reimbursement decisions and reimbursement lists; and increased flexibility in defining drug programmes. Both amendments are still at a draft stage and many aspects of the new regulations remain unclear. Nonetheless, the overall direction of some of the changes is already evident and warrants discussion due to their high expected impact on pharmaceutical and device manufacturers. Here we evaluate the main changes proposed to the reimbursement of drugs, vaccines, and medical devices, and examine the impact they are likely to have on market access and pharmaceutical industry in Poland. PMID:29081924

  3. Medical applications of superconducting quantum interference devices

    International Nuclear Information System (INIS)

    Uehara, Gen

    2011-01-01

    SQUIDs (Superconducting Quantum Interference Devices) are applied to clinical areas and basic medical science fields because of their potential for measuring a minute magnetic signal from the human body. Magnetoencephalography, one of their applications, is used for the functional mapping of the brain cortex before surgery and the localization of focus of epilepsy. Recently, their applications to the early-stage detection of dementia and the localization of brain ischemia are suggested. Another application of SQUIDs is magnetospinography, which detects the conduction block in spinal cord signal propagation. (author)

  4. Design controls for the medical device industry

    CERN Document Server

    Teixeira, Marie B

    2013-01-01

    The second edition of a bestseller, Design Controls for the Medical Device Industry provides a comprehensive review of the latest design control requirements, as well as proven tools and techniques to ensure your company's design control program evolves in accordance with current industry practice. The text assists in the development of an effective design control program that not only satisfies the US FDA Quality System Regulation (QSR) and ISO 9001 and 13485 standards, but also meets today's third-party auditor/investigator expectations and saves you valuable time and money.The author's cont

  5. 76 FR 18227 - Molecular and Clinical Genetics Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-04-01

    ...] Molecular and Clinical Genetics Panel of the Medical Devices Advisory Committee; Notice of Meeting... comment period for the notice announcing a meeting of the Molecular and Clinical Genetics Panel (the panel... Clinical Genetics Panel of the Medical Devices Advisory Committee, and the opening of a public docket to...

  6. High-risk medical devices, children and the FDA: regulatory challenges facing pediatric mechanical circulatory support devices.

    Science.gov (United States)

    Almond, Christopher S D; Chen, Eric A; Berman, Michael R; Less, Joanne R; Baldwin, J Timothy; Linde-Feucht, Sarah R; Hoke, Tracey R; Pearson, Gail D; Jenkins, Kathy; Duncan, Brian W; Zuckerman, Bram D

    2007-01-01

    Pediatric mechanical circulatory support is a critical unmet need in the United States. Infant- and child-sized ventricular assist devices are currently being developed largely through federal contracts and grants through the National Heart, Lung, and Blood Institute (NHLBI). Human testing and marketing of high-risk devices for children raises epidemiologic and regulatory issues that will need to be addressed. Leaders from the US Food and Drug Administration (FDA), NHLBI, academic pediatric community, and industry convened in January 2006 for the first FDA Workshop on the Regulatory Process for Pediatric Mechanical Circulatory Support Devices. The purpose was to provide the pediatric community with an overview of the federal regulatory process for high-risk medical devices and to review the challenges specific to the development and regulation of pediatric mechanical circulatory support devices. Pediatric mechanical circulatory support present significant epidemiologic, logistic, and financial challenges to industry, federal regulators, and the pediatric community. Early interactions with the FDA, shared appreciation of challenges, and careful planning will be critical to avoid unnecessary delays in making potentially life-saving devices available for children. Collaborative efforts to address these challenges are warranted.

  7. Real-time volume rendering of digital medical images on an iOS device

    Science.gov (United States)

    Noon, Christian; Holub, Joseph; Winer, Eliot

    2013-03-01

    Performing high quality 3D visualizations on mobile devices, while tantalizingly close in many areas, is still a quite difficult task. This is especially true for 3D volume rendering of digital medical images. Allowing this would empower medical personnel a powerful tool to diagnose and treat patients and train the next generation of physicians. This research focuses on performing real time volume rendering of digital medical images on iOS devices using custom developed GPU shaders for orthogonal texture slicing. An interactive volume renderer was designed and developed with several new features including dynamic modification of render resolutions, an incremental render loop, a shader-based clipping algorithm to support OpenGL ES 2.0, and an internal backface culling algorithm for properly sorting rendered geometry with alpha blending. The application was developed using several application programming interfaces (APIs) such as OpenSceneGraph (OSG) as the primary graphics renderer coupled with iOS Cocoa Touch for user interaction, and DCMTK for DICOM I/O. The developed application rendered volume datasets over 450 slices up to 50-60 frames per second, depending on the specific model of the iOS device. All rendering is done locally on the device so no Internet connection is required.

  8. 47 CFR 95.1119 - Specific requirements for wireless medical telemetry devices operating in the 608-614 MHz band.

    Science.gov (United States)

    2010-10-01

    ... devices operating in the 608-614 MHz band. For a wireless medical telemetry device operating within the... 47 Telecommunication 5 2010-10-01 2010-10-01 false Specific requirements for wireless medical telemetry devices operating in the 608-614 MHz band. 95.1119 Section 95.1119 Telecommunication FEDERAL...

  9. Clinical protocol levels are required in laboratory animal surgery when using medical devices: experiences with ureteral replacement surgery in goats

    NARCIS (Netherlands)

    Jonge, P.K.J.D. de; Sloff, M.; Janke, H.P.; Kortmann, B.B.M.; Gier, R.P.E. de; Geutjes, P.J.; Oosterwijk, E.; Feitz, W.F.J.

    2017-01-01

    It is common to test medical devices in large animal studies that are or could also be used in humans. In this short report we describe the use of a ureteral J-stent for the evaluation of biodegradable tubular constructs for tissue reconstruction, and the regeneration of ureters in Saanen goats.

  10. OpenICE medical device interoperability platform overview and requirement analysis.

    Science.gov (United States)

    Arney, David; Plourde, Jeffrey; Goldman, Julian M

    2018-02-23

    We give an overview of OpenICE, an open source implementation of the ASTM standard F2761 for the Integrated Clinical Environment (ICE) that leverages medical device interoperability, together with an analysis of the clinical and non-functional requirements and community process that inspired its design.

  11. Lessons learned: mobile device encryption in the academic medical center.

    Science.gov (United States)

    Kusche, Kristopher P

    2009-01-01

    The academic medical center is faced with the unique challenge of meeting the multi-faceted needs of both a modern healthcare organization and an academic institution, The need for security to protect patient information must be balanced by the academic freedoms expected in the college setting. The Albany Medical Center, consisting of the Albany Medical College and the Albany Medical Center Hospital, was challenged with implementing a solution that would preserve the availability, integrity and confidentiality of business, patient and research data stored on mobile devices. To solve this problem, Albany Medical Center implemented a mobile encryption suite across the enterprise. Such an implementation comes with complexities, from performance across multiple generations of computers and operating systems, to diversity of application use mode and end user adoption, all of which requires thoughtful policy and standards creation, understanding of regulations, and a willingness and ability to work through such diverse needs.

  12. 21 CFR 801.1 - Medical devices; name and place of business of manufacturer, packer or distributor.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical devices; name and place of business of manufacturer, packer or distributor. 801.1 Section 801.1 Food and Drugs FOOD AND DRUG ADMINISTRATION... § 801.1 Medical devices; name and place of business of manufacturer, packer or distributor. (a) The...

  13. The future of the pharmaceutical, biological and medical device industry

    Directory of Open Access Journals (Sweden)

    Burgess LJ

    2011-09-01

    Full Text Available Lesley J Burgess, Marli TerblancheTREAD Research/Cardiology Unit, Department of Internal Medicine, Tygerberg Hospital and University of Stellenbosch, Parow, South AfricaAbstract: Numerous factors contribute to the declining pharmaceutical industry on the one hand and the rapidly growing generic industry together with the growing importance of medical devices and biologicals on the other. It is clear that the pharmaceutical industry is going to undergo a change in the next decade in order to meet the current challenges facing it and ultimately sustain its profitability and growth. This paper aims to identify a number of fairly obvious trends that are likely to have a significant impact on the product development pipeline in the next decade. It is more than clear that the current production pipeline for pharmaceutical, biotechnology and medical device industries is no longer sustainable and that urgent interventions are required in order to maintain its current level of profitability.Keywords: pharmaceutical industry, personalized medicine, trends, generics, biotechnology

  14. MELLO: Medical lifelog ontology for data terms from self-tracking and lifelog devices.

    Science.gov (United States)

    Kim, Hye Hyeon; Lee, Soo Youn; Baik, Su Youn; Kim, Ju Han

    2015-12-01

    The increasing use of health self-tracking devices is making the integration of heterogeneous data and shared decision-making more challenging. Computational analysis of lifelog data has been hampered by the lack of semantic and syntactic consistency among lifelog terms and related ontologies. Medical lifelog ontology (MELLO) was developed by identifying lifelog concepts and relationships between concepts, and it provides clear definitions by following ontology development methods. MELLO aims to support the classification and semantic mapping of lifelog data from diverse health self-tracking devices. MELLO was developed using the General Formal Ontology method with a manual iterative process comprising five steps: (1) defining the scope of lifelog data, (2) identifying lifelog concepts, (3) assigning relationships among MELLO concepts, (4) developing MELLO properties (e.g., synonyms, preferred terms, and definitions) for each MELLO concept, and (5) evaluating representative layers of the ontology content. An evaluation was performed by classifying 11 devices into 3 classes by subjects, and performing pairwise comparisons of lifelog terms among 5 devices in each class as measured using the Jaccard similarity index. MELLO represents a comprehensive knowledge base of 1998 lifelog concepts, with 4996 synonyms for 1211 (61%) concepts and 1395 definitions for 926 (46%) concepts. The MELLO Browser and MELLO Mapper provide convenient access and annotating non-standard proprietary terms with MELLO (http://mello.snubi.org/). MELLO covers 88.1% of lifelog terms from 11 health self-tracking devices and uses simple string matching to match semantically similar terms provided by various devices that are not yet integrated. The results from the comparisons of Jaccard similarities between simple string matching and MELLO matching revealed increases of 2.5, 2.2, and 5.7 folds for physical activity,body measure, and sleep classes, respectively. MELLO is the first ontology for

  15. Polymer coating embolism from intravascular medical devices - a clinical literature review.

    Science.gov (United States)

    Chopra, Amitabh M; Mehta, Monik; Bismuth, Jean; Shapiro, Maksim; Fishbein, Michael C; Bridges, Alina G; Vinters, Harry V

    Over the past three decades, lubricious (hydrophobic and/or hydrophilic) polymer-coated devices have been increasingly adopted by interventional physicians and vascular surgeons to access and treat a wider range of clinical presentations. Recent clinical literature highlights the presence of polymer coating emboli within the anatomy - a result of coating separation from an intravascular device - and associates it with a range of adverse clinical sequelae. The 2015 U.S. Food and Drug Administration safety communication titled "Lubricious Coating Separation from Intravascular Medical Devices" acknowledges these concerns and concludes that it will work with stakeholders to develop nonclinical test methodologies, establish performance criteria, and identify gaps in current national and international device standards for coating integrity performance. Despite this communication and multiple case reports from interventional physicians, pathologists, dermatologists and other involved physician specialties, polymer coating embolism remains clinically underrecognized. This article consolidates the available literature on polymer coating embolism (1986-2016) and highlights the following relevant information for the physician: (a) the history and elusive nature of polymer coating embolism; (b) potential incidence rates of this phenomenon; (c) reported histologic findings and clinical effects of polymer emboli in the anatomy; (d) the importance of the collaborative clinician-pathologist partnership to report polymer embolism findings; and (e) the importance to study particulate release from intravascular devices so as to further understand and potentially evolve coated interventional technologies. Preliminary research on coatings highlights the potential of using iterations of coatings on medical devices that attain the desired therapeutic result and mitigate or eliminate particulates altogether. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  16. FDA (Food and Drug Administration) Compliance Program Guidance Manual (FY 88). Section 4. Medical and radiological devices

    International Nuclear Information System (INIS)

    1988-01-01

    The FDA Compliance Program Guidance Manual provides a system for issuing and filing program plans and instructions directed to Food and Drug Administration Field operations for project implementation. Section IV provides those chapters of the Compliance Program Guidance Manual which pertain to the areas of medical and radiological devices. Some of the areas of coverage include laser and sunlamp standards inspections, compliance testing of various radiation-emitting products such as television receivers and microwave ovens, emergency response planning and policy, premarket approval and device manufacturers inspections, device problem reporting, sterilization of devices, and consumer education programs on medical and radiological devices

  17. An open prospective study evaluating efficacy and safety of a new medical device for rectal application of activated carbon in the treatment of chronic, uncomplicated perianal fistulas

    DEFF Research Database (Denmark)

    Zawadzki, Antoni; Johnson, Louis Banka; Bohe, Måns

    2017-01-01

    PURPOSE: It has been proposed that biological/chemical substances in the intestine might play a role in the occurrence and deterioration of perianal fistulas. Elimination of such unidentified factors from the lower gastrointestinal tract might offer a new strategy for the management of anal...... fistulas. The aim of this study was to evaluate the clinical effects on non-Crohn's disease perianal fistula healing, and the safety and tolerability of a new medical device that applies high-purity, high-activity granular activated carbon locally into the rectum twice daily of patients with perianal...... fistulas without any concomitant medication. METHODS: An open, single-arm, prospective study with active treatment for 8 weeks and an optional follow-up until week 24 ( ClinicalTrial.gov identifier NCT01462747) among patients with chronic, uncomplicated perianal fistulas scheduled for surgery was conducted...

  18. Mobile Medical Apps and mHealth Devices: A Framework to Build Medical Apps and mHealth Devices in an Ethical Manner to Promote Safer Use - A Literature Review.

    Science.gov (United States)

    Sharp, Mary; O'Sullivan, Declan

    2017-01-01

    This paper presents a preliminary literature review in the area of ethics in the development of Mobile Medical Apps and mHealth. The review included both direct health apps and also apps marketed under the area of well-being in addition to mHealth devices. The following words and combinations of them were used to carry out the search for publications, mHealth, Apps, Ethics. The search engines used were Google Scholar, and PubMed. The paper is restricted to publications since 2012. The total number of papers found was 1,920 of which 84 were reviewed. The reason for so few being reviewed was that the majority only considered security. The search revealed many papers dealing with security for all types of apps and mHealth devices but there are very few papers dealing with the ethical issues related to Apps or mHealth devices in the area. It is noted however that the number of apps is increasing in number exponentially and therefore it is argued that it is necessary to pay attention to the ethical aspects. There are now estimated to be 165,000 apps available in this area. How ethics are addressed in health and well-being apps is important as they can have an effect on the health of the individual using them. In a similar way, the need for addressing ethical issues for development of well-being apps is evident. In a study [1] it was noted that even though Electronic Health Record (EHR) was the highest ranked tablet-related task only one third of clinicians said that EHR was optimized for smartphones. When apps are integrated with the EHR they fully optimize productivity. In the same study the significant challenges identified included the method of evaluation and selection of mobile health solutions in order to ensure that clinical outcomes, care and efficiency are included. Security is mentioned but again wider ethical issues were not a consideration. From the literature review it is clear that there is a need for guidelines for how developers of medical ad well

  19. 76 FR 6623 - Molecular and Clinical Genetics Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2011-02-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0066] Molecular and Clinical Genetics Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY... public. Name of Committee: Molecular and Clinical Genetics Panel of the Medical Devices Advisory...

  20. A Fuzzy method for the usability evaluation of nuclear medical equipment

    Energy Technology Data Exchange (ETDEWEB)

    Grecco, Cláudio H.S.; Santos, Isaac J.A.L.; Farias, Marcos S.; Farias, Larissa P.; Filho, Alfredo M.V., E-mail: grecco@ien.gov.br, E-mail: luquetti@ien.gov.br, E-mail: msantana@ien.gov.br, E-mail: larissapfarias@ymail.com, E-mail: marques@ien.gov.br [Instituto de Engenharia Nuclear (DENN/IEN/CNEN/RJ), Rio de Janeiro, RJ (Brazil). Departamento de Engenharia Nuclear

    2017-11-01

    To avoid errors when handling nuclear medical equipment, it is important to develop products with a high degree of usability. This can be achieved by performing usability evaluations in the product development process to detect and mitigate potential usability problems. Usability evaluation focuses on how well users can learn and use a product to achieve their goals. Thus, the usability evaluation has become recognized as a valuable complement to the established approaches to design good user interfaces, to reduce incidents and accidents as well the time required to learn how to use the equipment. To gather information about usability, practitioners use a variety of methods that gather feedback from users about an existing interface or plans related to a new interface. A wide range of usability evaluation methods have been proposed, but few methods focus on developing an objective and practical evaluation method for usability. Moreover, the usability evaluations are based on human judgments and most methods cannot fully solve the subjectivity of these evaluations. In order to remedy this deficiency, the purpose of this work is to adopt a Fuzzy Set Theory (FST) approach to establish a method for the usability evaluation of nuclear medical equipment based on usability heuristics for user interface design and international standards for ergonomics of human-system interaction. To exemplify the method we performed a usability evaluating of the Digital Spectrometer ESP 13004 by testing it with representative users. The results showed that the method is a proactive tool to provide a basis for checking usability of medical device interfaces. (author)

  1. A Fuzzy method for the usability evaluation of nuclear medical equipment

    International Nuclear Information System (INIS)

    Grecco, Cláudio H.S.; Santos, Isaac J.A.L.; Farias, Marcos S.; Farias, Larissa P.; Filho, Alfredo M.V.

    2017-01-01

    To avoid errors when handling nuclear medical equipment, it is important to develop products with a high degree of usability. This can be achieved by performing usability evaluations in the product development process to detect and mitigate potential usability problems. Usability evaluation focuses on how well users can learn and use a product to achieve their goals. Thus, the usability evaluation has become recognized as a valuable complement to the established approaches to design good user interfaces, to reduce incidents and accidents as well the time required to learn how to use the equipment. To gather information about usability, practitioners use a variety of methods that gather feedback from users about an existing interface or plans related to a new interface. A wide range of usability evaluation methods have been proposed, but few methods focus on developing an objective and practical evaluation method for usability. Moreover, the usability evaluations are based on human judgments and most methods cannot fully solve the subjectivity of these evaluations. In order to remedy this deficiency, the purpose of this work is to adopt a Fuzzy Set Theory (FST) approach to establish a method for the usability evaluation of nuclear medical equipment based on usability heuristics for user interface design and international standards for ergonomics of human-system interaction. To exemplify the method we performed a usability evaluating of the Digital Spectrometer ESP 13004 by testing it with representative users. The results showed that the method is a proactive tool to provide a basis for checking usability of medical device interfaces. (author)

  2. Interoperability of medical device information and the clinical applications: an HL7 RMIM based on the ISO/IEEE 11073 DIM.

    Science.gov (United States)

    Yuksel, Mustafa; Dogac, Asuman

    2011-07-01

    Medical devices are essential to the practice of modern healthcare services. Their benefits will increase if clinical software applications can seamlessly acquire the medical device data. The need to represent medical device observations in a format that can be consumable by clinical applications has already been recognized by the industry. Yet, the solutions proposed involve bilateral mappings from the ISO/IEEE 11073 Domain Information Model (DIM) to specific message or document standards. Considering that there are many different types of clinical applications such as the electronic health record and the personal health record systems, the clinical workflows, and the clinical decision support systems each conforming to different standard interfaces, detailing a mapping mechanism for every one of them introduces significant work and, thus, limits the potential health benefits of medical devices. In this paper, to facilitate the interoperability of clinical applications and the medical device data, we use the ISO/IEEE 11073 DIM to derive an HL7 v3 Refined Message Information Model (RMIM) of the medical device domain from the HL7 v3 Reference Information Mode (RIM). This makes it possible to trace the medical device data back to a standard common denominator, that is, HL7 v3 RIM from which all the other medical domains under HL7 v3 are derived. Hence, once the medical device data are obtained in the RMIM format, it can easily be transformed into HL7-based standard interfaces through XML transformations because these interfaces all have their building blocks from the same RIM. To demonstrate this, we provide the mappings from the developed RMIM to some of the widely used HL7 v3-based standard interfaces.

  3. Open-Source Medical Devices (OSMD) Design of a Small Animal Radiotherapy System

    Science.gov (United States)

    Prajapati, S.; Mackie, T. R.; Jeraj, R.

    2014-03-01

    Open-Source Medical Devices (OSMD) was initiated with the goal of facilitating medical research by developing medical technologies including both hardware and software on an open-source platform. Our first project was to develop an integrated imaging and radiotherapy device for small animals that includes computed tomography (CT), positron emission tomography (PET) and radiation therapy (RT) modalities for which technical specifications were defined in the first OSMD conference held in Madison, Wisconsin, USA in December 2011. This paper specifically focuses on the development of a small animal RT (micro-RT) system by designing a binary micro multileaf collimator (bmMLC) and a small animal treatment planning system (SATPS) to enable intensity modulated RT (IMRT). Both hardware and software projects are currently under development and their current progresses are described. After the development, both bmMLC and TPS will be validated and commissioned for a micro-RT system. Both hardware design and software development will be open-sourced after completion.

  4. 21 CFR 801.128 - Exceptions or alternatives to labeling requirements for medical devices held by the Strategic...

    Science.gov (United States)

    2010-04-01

    ... requirements for medical devices held by the Strategic National Stockpile. 801.128 Section 801.128 Food and... requirements for medical devices held by the Strategic National Stockpile. (a) The appropriate FDA Center... Strategic National Stockpile. (b)(1)(i) A Strategic National Stockpile official or any entity that...

  5. Educational value of pocket-sized ultrasound devices to improve understanding of ultrasound examination principles and sonographic anatomy for medical student.

    Directory of Open Access Journals (Sweden)

    Eun Young Kim

    Full Text Available Medical students must understand the principles of ultrasonography (US, because US examinations are an important component of patient care in clinical practice. Pocket-sized ultrasound devices have the benefits of accessibility and ease of use. The primary objective of the present study was to evaluate the educational value of these devices in terms of improving medical student interest and understanding of US and sonographic anatomy.We added a US training program comprised of a self-study learning module and a hands-on training session to a two-week block curriculum of medical imaging for first year medical students (n = 40. Multiple pocket-sized US devices were used on a small-group basis during a single afternoon. Students were asked to complete a questionnaire before and after the US training session; these two questionnaires contained 6 and 10 questions, respectively, which were rated by students using a five-point Likert scale. In addition, understanding of sonographic anatomy was tested before and after the training program.Forty students completed the two questionnaires and the anatomy-related tests. Students found the program educationally valuable (4.37 ± 0.54 of 5 and reported that US practice was useful for improving their understanding of the principles of US examinations (4.23 ± 0.66 of 5 and sonographic anatomy (4.40 ± 0.55 of 5. Overall confidence at performing US examinations and understanding of sonographic anatomy were significantly increased after US training (increased overall confidence score, 1.87 ± 0.91 and improvement in sonographic anatomy score, 6.55 ± 1.55, p values < 0.001.US training using pocket-sized ultrasound devices was found to be educationally valuable for medical students in terms of improving understanding of US principles and familiarizing students with sonographic anatomy.

  6. Comparison of Transplant Waitlist Outcomes for Pediatric Candidates Supported by Ventricular Assist Devices Versus Medical Therapy.

    Science.gov (United States)

    Law, Sabrina P; Oron, Assaf P; Kemna, Mariska S; Albers, Erin L; McMullan, D Michael; Chen, Jonathan M; Law, Yuk M

    2018-05-01

    Ventricular assist devices have gained popularity in the management of refractory heart failure in children listed for heart transplantation. Our primary aim was to compare the composite endpoint of all-cause pretransplant mortality and loss of transplant eligibility in children who were treated with a ventricular assist device versus a medically managed cohort. This was a retrospective cohort analysis. Data were obtained from the Scientific Registry of Transplant Recipients. The at-risk population (n = 1,380) was less than 18 years old, either on a ventricular assist device (605 cases) or an equivalent-severity, intensively medically treated group (referred to as MED, 775 cases). None. The impact of ventricular assist devices was estimated via Cox proportional hazards regression (hazard ratio), dichotomizing 1-year outcomes to "poor" (22%: 193 deaths, 114 too sick) versus all others (940 successful transplants, 41 too healthy, 90 censored), while adjusting for conventional risk factors. Among children 0-12 months old, ventricular assist device was associated with a higher risk of poor outcomes (hazard ratio, 2.1; 95% CI, 1.5-3.0; p comparative study of ventricular assist devices versus medical therapy in children. Age is a significant modulator of waitlist outcomes for children with end-stage heart failure supported by ventricular assist device, with the impact of ventricular assist devices being more beneficial in adolescents.

  7. 21 CFR 610.42 - Restrictions on use for further manufacture of medical devices.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Restrictions on use for further manufacture of medical devices. 610.42 Section 610.42 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH... for Communicable Disease Agents § 610.42 Restrictions on use for further manufacture of medical...

  8. RESULTS OF THE SURVEY CONDUCTED AMONG OPHTHALMOLOGISTS ON THE ISSUE OF EQUIPMENT OF MEDICAL INSTITUTIONS WITH OPHTHALMOLOGY DEVICES

    Directory of Open Access Journals (Sweden)

    S. V. Seraphimov

    2017-01-01

    Full Text Available Introduction. The problem of limited accessibility and quality of ophthalmic medical care remains one of the leading ones in the national healthcare. This article presents results of the survey conducted among ophthalmologists about the effect of large-scale equipment of all medical institutions in the Leningrad Region with modern ophthalmologic devices over the recent years.Objective is to determine the contribution of the health care modernization program to equipping the medical institutions of the Leningrad Region with modern ophthalmologic medical devices, and to identify the main areas for improving the ophthalmologic care for residents of the Leningrad region with cataracts.Materials and methods. According to a specially developed questionnaire, 105 ophthalmologists from the Leningrad Region were interviewed. The survey was conducted among physicians working both in out-patient medical facilities and in medical facilities with in-patient modalities.Results. The results of the study confirmed positive changes that occurred in recent years as a result of equipping medical institutions with modern medical devices. Almost two-thirds (59.9% of respondents noted that equipping with modern medical devices had a significant impact on the quality of the medical and diagnostic measures carried out in healthcare facilities of the region.Conclusions. The equipment had a significant impact on the diagnosis and treatment of all kinds of diseases of the eye and its appendages, especially such eye disease which is so common among the population of the Leningrad Region as cataracts (75.0 per 100 ophthalmologists surveyed. At the same time, in spite of these efforts, the standard for equipping ophthalmologic departments in individual medical institutions has not been fully provided. Only every fifth (20.9% ophthalmologist noted during the survey that the list of available ophthalmic devices was sufficient, and that they all worked properly.

  9. [Study on restriction factors and countermeasures of influence of China medical devices competitiveness].

    Science.gov (United States)

    Zhang, Zhijun

    2012-07-01

    Recent years, China medical devices industry has been a sunrise industry with widely-ranged products, high-tech innovation, and booming market demands. But with the globalization of market economy, China industry is still in the inferior position of competition. How to promote the industrial structure transition, increase scientific and technological level, speed up the updating of products, enhance the international competitiveness is one of the major tasks to maintain the healthy development of industry. This article makes a study on current situation of China medical devices industry, analyses the new opportunities, challenges and restriction factors, provides the countermeasures of strengthening industry competitiveness as well.

  10. A systematic review of electronic multi-compartment medication devices with reminder systems for improving adherence to self-administered medications.

    Science.gov (United States)

    Paterson, Mary; Kinnear, Moira; Bond, Christine; McKinstry, Brian

    2017-06-01

    Many patients experience difficulties adhering to medication regimes. For people who forget or get confused about medication, there are products to help them such as multi-compartment medication devices (MMDs). Some of these, known as electronic MMDs (eMMDs), use audible and/or visual signals to prompt the patient when to take medication, dispense medications, give instructions to the patient, and contact a caregiver (mobile Internet or text to a carer) as needed. To systematically review the literature on the use of eMMDs, to determine what evidence for their effectiveness is available. A comprehensive literature search of 10 databases, plus an Internet search and hand searching was conducted, using the MeSH terms reminder systems/patient compliance/medication adherence. There were no date restrictions. Inclusion criteria were patients in any community setting, in any country and with no restrictions of age, gender, ethnicity or medical condition, using an eMMD. Peer-reviewed quantitative or qualitative studies of any design were included. Of 805 abstracts identified and 99 full text papers retrieved, six met the inclusion criteria. Five of the studies reported adherence to medication regimes; one reported design factors to improve adherence. Adherence varied by the context of the reminders, the target group and usability of the devices. The studies were small scale and only one was a well conducted randomised controlled trial. Overall methodological quality of the studies was poor. Although positive effects on adherence were reported further, rigorously conducted, studies are needed to inform the use of eMMDs. © 2016 Royal Pharmaceutical Society.

  11. Halo and spillover effect illustrations for selected beneficial medical devices and drugs

    Directory of Open Access Journals (Sweden)

    Brent D. Kerger

    2016-09-01

    Full Text Available Abstract Background Negative news media reports regarding potential health hazards of implanted medical devices and pharmaceuticals can lead to a ‘negative halo effect,’ a phenomenon whereby judgments about a product or product type can be unconsciously altered even though the scientific support is tenuous. To determine how a ‘negative halo effect’ may impact the rates of use and/or explantation of medical products, we analyzed the occurrence of such an effect on three implanted medical devices and one drug: 1 intrauterine contraceptive devices (IUDs; 2 silicone gel-filled breast implants (SGBI; 3 metal-on-metal hip implants (MoM; and 4 the drug Tysabri. Methods Data on IUD use from 1965 to 2008 were gathered from the Department of Health and Human Services Vital and Health Statistics and peer-reviewed publications. Data regarding SGBI implant and explantation rates from 1989 to 2012 were obtained from the Institute of Medicine and the American Society of Plastic Surgeons. MoM implant and explantation data were extracted from the England and Wales National Joint Registry and peer-reviewed publications. Tysabri patient data were reported by Elan Corporation or Biogen Idec Inc. Data trends for all products were compared with historical recall or withdrawal events and discussed in the context of public perceptions following such events. Results We found that common factors altered public risk perceptions and patterns of continued use. First, a negative halo effect may be driven by continuing patient anxiety despite positive clinical outcomes. Second, negative reports about one product can spill over to affect the use of dissimilar products in the same category. Third, a negative halo effect on an entire category of medical devices can be sustained regardless of the scientific findings pertaining to safety. Fourth, recovery of a product’s safety reputation and prevalent use may take decades in the U.S., even while these products may

  12. Urolithiasis: evaluation, dietary factors, and medical management

    DEFF Research Database (Denmark)

    Jung, Helene; Andonian, Sero; Assimos, Dean

    2017-01-01

    PURPOSE: The aim of this review was to provide current best evidence for evaluation, dietary, and medical management of patients with urolithiasis. METHODS: Literature addressing evaluation, dietary, and medical management of urolithiasis was searched. Papers were analyzed and rated according...... the life of stone-forming individuals very differently, and that evaluation and medical management should be personalized according to risk of recurrence, severity of stone disease, presence of associated medical conditions, and patient's motivation. With regard to evaluation, dietary and medical...... management of patients with urolithiasis evidence from the literature suggest that selective metabolic evaluation may lead to rational dietary and medical management. Statements based on LOE and GOR are provided to guide clinical practice. CONCLUSION: The provided evidence for evaluation of patients...

  13. Integration of human factors and ergonomics during medical device design and development: it's all about communication.

    Science.gov (United States)

    Vincent, Christopher James; Li, Yunqiu; Blandford, Ann

    2014-05-01

    Manufacturers of interactive medical devices, such as infusion pumps, need to ensure that devices minimise the risk of unintended harm during use. However, development teams face challenges in incorporating Human Factors. The aim of the research reported here was to better understand the constraints under which medical device design and development take place. We report the results of a qualitative study based on 19 semi-structured interviews with professionals involved in the design, development and deployment of interactive medical devices. A thematic analysis was conducted. Multiple barriers to designing for safety and usability were identified. In particular, we identified barriers to communication both between the development organisation and the intended users and between different teams within the development organisation. We propose the use of mediating representations. Artefacts such as personas and scenarios, known to provide integration across multiple perspectives, are an essential component of designing for safety and usability. Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  14. The Role of Healthcare Technology Management in Facilitating Medical Device Cybersecurity.

    Science.gov (United States)

    Busdicker, Mike; Upendra, Priyanka

    2017-09-02

    This article discusses the role of healthcare technology management (HTM) in medical device cybersecurity and outlines concepts that are applicable to HTM professionals at a healthcare delivery organization or at an integrated delivery network, regardless of size. It provides direction for HTM professionals who are unfamiliar with the security aspects of managing healthcare technologies but are familiar with standards from The Joint Commission (TJC). It provides a useful set of recommendations, including relevant references for incorporating good security practices into HTM practice. Recommendations for policies, procedures, and processes referencing TJC standards are easily applicable to HTM departments with limited resources and to those with no resource concerns. The authors outline processes from their organization as well as best practices learned through information sharing at AAMI, National Health Information Sharing and Analysis Center (NH-ISAC), and Medical Device Innovation, Safety, and Security Consortium (MDISS) conferences and workshops.

  15. Influence of Mobile Phones on the Quality of ECG Signal Acquired by Medical Devices

    Science.gov (United States)

    Buczkowski, T.; Janusek, D.; Zavala-Fernandez, H.; Skrok, M.; Kania, M.; Liebert, A.

    2013-10-01

    Health aspects of the use of radiating devices, like mobile phones, are still a public concern. Stand-alone electrocardiographic systems and those built-in, more sophisticated, medical devices have become a standard tool used in everyday medical practice. GSM mobile phones might be a potential source of electromagnetic interference (EMI) which may affect reliability of medical appliances. Risk of such event is particularly high in places remote from GSM base stations in which the signal received by GSM mobile phone is weak. In such locations an increase in power of transmitted radio signal is necessary to enhance quality of the communication. In consequence, the risk of interference of electronic devices increases because of the high level of EMI. In the present paper the spatial, temporal, and spectral characteristics of the interference have been examined. The influence of GSM mobile phone on multilead ECG recordings was studied. It was observed that the electrocardiographic system was vulnerable to the interference generated by the GSM mobile phone working with maximum transmit power and in DTX mode when the device was placed in a distance shorter than 7.5 cm from the ECG electrode located on the surface of the chest. Negligible EMI was encountered at any longer distance.

  16. Improvised explosive devices: pathophysiology, injury profiles and current medical management.

    Science.gov (United States)

    Ramasamy, A; Hill, A M; Clasper, J C

    2009-12-01

    The improvised explosive device (IED), in all its forms, has become the most significant threat to troops operating in Afghanistan and Iraq. These devices range from rudimentary home made explosives to sophisticated weapon systems containing high-grade explosives. Within this broad definition they may be classified as roadside explosives and blast mines, explosive formed pojectile (EFP) devices and suicide bombings. Each of these groups causeinjury through a number of different mechanisms and can result in vastly different injury profiles. The "Global War on Terror" has meant that incidents which were previously exclusively seen in conflict areas, can occur anywhere, and clinicians who are involved in emergency trauma care may be required to manage casualties from similar terrorist attacks. An understanding of the types of devices and their pathophysiological effects is necessary to allow proper planning of mass casualty events and to allow appropriate management of the complex poly-trauma casualties they invariably cause. The aim of this review article is to firstly describe the physics and injury profile from these different devices and secondly to present the current clinical evidence that underpins their medical management.

  17. An in vitro method for detecting chemical sensitization using human reconstructed skin models and its applicability to cosmetic, pharmaceutical, and medical device safety testing.

    Science.gov (United States)

    McKim, James M; Keller, Donald J; Gorski, Joel R

    2012-12-01

    Chemical sensitization is a serious condition caused by small reactive molecules and is characterized by a delayed type hypersensitivity known as allergic contact dermatitis (ACD). Contact with these molecules via dermal exposure represent a significant concern for chemical manufacturers. Recent legislation in the EU has created the need to develop non-animal alternative methods for many routine safety studies including sensitization. Although most of the alternative research has focused on pure chemicals that possess reasonable solubility properties, it is important for any successful in vitro method to have the ability to test compounds with low aqueous solubility. This is especially true for the medical device industry where device extracts must be prepared in both polar and non-polar vehicles in order to evaluate chemical sensitization. The aim of this research was to demonstrate the functionality and applicability of the human reconstituted skin models (MatTek Epiderm(®) and SkinEthic RHE) as a test system for the evaluation of chemical sensitization and its potential use for medical device testing. In addition, the development of the human 3D skin model should allow the in vitro sensitization assay to be used for finished product testing in the personal care, cosmetics, and pharmaceutical industries. This approach combines solubility, chemical reactivity, cytotoxicity, and activation of the Nrf2/ARE expression pathway to identify and categorize chemical sensitizers. Known chemical sensitizers representing extreme/strong-, moderate-, weak-, and non-sensitizing potency categories were first evaluated in the skin models at six exposure concentrations ranging from 0.1 to 2500 µM for 24 h. The expression of eight Nrf2/ARE, one AhR/XRE and two Nrf1/MRE controlled gene were measured by qRT-PCR. The fold-induction at each exposure concentration was combined with reactivity and cytotoxicity data to determine the sensitization potential. The results demonstrated that

  18. Cost effectiveness of medical devices to diagnose pre-eclampsia in low-resource settings

    Directory of Open Access Journals (Sweden)

    Zoë M. McLaren

    Full Text Available Background: Maternal mortality remains a major health challenge facing developing countries, with pre-eclampsia accounting for up to 17% of maternal deaths. Diagnosis requires skilled health providers and devices that are appropriate for low-resource settings. This study presents the first cost-effectiveness analysis of multiple medical devices used to diagnose pre-eclampsia in low- and middle-income countries (LMICs. Methods: Blood pressure and proteinuria measurement devices, identified from compendia for LMICs, were included. We developed a decision tree framework to assess the cost-effectiveness of each device using parameter values that reflect the general standard of care based on a survey of relevant literature and expert opinion. We examined the sensitivity of our results using one-way and second-order probabilistic multivariate analyses. Results: Because the disability-adjusted life years (DALYs averted for each device were very similar, the results were influenced by the per-use cost ranking. The most cost-effective device combination was a semi-automatic blood pressure measurement device and visually read urine strip test with the lowest combined per-use cost of $0.2004 and an incremental cost effectiveness ratio of $93.6 per DALY gained relative to a baseline with no access to diagnostic devices. When access to treatment is limited, it is more cost-effective to improve access to treatment than to increase testing rates or diagnostic device sensitivity. Conclusions: Our findings were not sensitive to changes in device sensitivity, however they were sensitive to changes in the testing rate and treatment rate. Furthermore, our results suggest that simple devices are more cost-effective than complex devices. The results underscore the desirability of two design features for LMICs: ease of use and accuracy without calibration. Our findings have important implications for policy makers, health economists, health care providers and

  19. Health technology assessment process of a cardiovascular medical device in four different settings.

    Science.gov (United States)

    Olry de Labry Lima, Antonio; Espín Balbino, Jaime; Lemgruber, Alexandre; Caro Martínez, Araceli; García-Mochón, Leticia; Martín Ruiz, Eva; Lessa, Fernanda

    2017-10-01

    Health technology assessment (HTA) is a tool to help the decision-making process. The aim is to describe methods and processes used in the reimbursement decision making for drug-eluting stents (DES) in four different settings. DES as a technology under study was selected according to different criteria, all of them agreed by a working group. A survey of key informants was designed. DES was evaluated following well-structured HTA processes. Nonetheless, scope for improvement was observed in relation to the data considered for the final decision, the transparency and inclusiveness of the process as well as in the methods employed. An attempt to describe the HTA processes of a well-known medical device.

  20. Effects of Sterilization Cycles on PEEK for Medical Device Application

    Science.gov (United States)

    Yap, Wai Teng; Foo, Soo Leong; Lee, Teck Kheng

    2018-01-01

    The effects of the sterilization process have been studied on medical grade thermoplastic polyetheretherketone (PEEK). For a reusable medical device, material reliability is an important parameter to decide its lifetime, as it will be subjected to the continuous steam sterilization process. A spring nature, clip component was selected out of a newly designed medical device (patented) to perform this reliability study. This clip component was sterilized for a predetermined number of cycles (2, 4, 6, 8, 10, 20…100) at 121 °C for 30 min. A significant decrease of ~20% in the compression force of the spring was observed after 30 cycles, and a ~6% decrease in the lateral dimension of the clip was observed after 50 cycles. No further significant change in the compression force or dimension was observed for the subsequent sterilization cycles. Vickers hardness and differential scanning calorimetry (DSC) techniques were used to characterize the effects of sterilization. DSC results exhibited no significant change in the degree of cure and melting behavior of PEEK before and after the sterilization. Hardness measurement exhibited an increase of ~49% in hardness after just 20 cycles. When an unsterilized sample was heated for repetitive cycles without the presence of moisture (121 °C, 10 and 20 cycles), only ~7% of the maximum change in hardness was observed. PMID:29466289

  1. Effects of Sterilization Cycles on PEEK for Medical Device Application.

    Science.gov (United States)

    Kumar, Amit; Yap, Wai Teng; Foo, Soo Leong; Lee, Teck Kheng

    2018-02-21

    The effects of the sterilization process have been studied on medical grade thermoplastic polyetheretherketone (PEEK). For a reusable medical device, material reliability is an important parameter to decide its lifetime, as it will be subjected to the continuous steam sterilization process. A spring nature, clip component was selected out of a newly designed medical device (patented) to perform this reliability study. This clip component was sterilized for a predetermined number of cycles (2, 4, 6, 8, 10, 20…100) at 121 °C for 30 min. A significant decrease of ~20% in the compression force of the spring was observed after 30 cycles, and a ~6% decrease in the lateral dimension of the clip was observed after 50 cycles. No further significant change in the compression force or dimension was observed for the subsequent sterilization cycles. Vickers hardness and differential scanning calorimetry (DSC) techniques were used to characterize the effects of sterilization. DSC results exhibited no significant change in the degree of cure and melting behavior of PEEK before and after the sterilization. Hardness measurement exhibited an increase of ~49% in hardness after just 20 cycles. When an unsterilized sample was heated for repetitive cycles without the presence of moisture (121 °C, 10 and 20 cycles), only ~7% of the maximum change in hardness was observed.

  2. Design and evaluation of pointing devices; Gestaltung und Evaluation von koordinatengebenden Interaktionsgeraeten

    Energy Technology Data Exchange (ETDEWEB)

    Krauss, L.; Zuehlke, D. [Kaiserslautern Univ. (Germany)

    2002-07-01

    Pointing devices e.g. the computer mouse are gaining considerable importance in modern human-machine-systems as a major part of the interaction interface between human beings and machines. During the dialogues with window-based operating systems the human being - the user - moves the cursor to a certain position on the screen by means of pointing devices. Microsoft products like WINDOWS have asserted themselves in the meantime in office applications and are currently conquering the market of industrial control systems as well. In office applications the mouse has become established as the most important pointing device for interaction. However, an 'office mouse' is not really suitable in a manufacturing environment. Only a few investigations exist evaluating alternatives to the mouse, which are suitable for industrial applications. At the Center of Human-Machine-Interaction (ZMMI) of the Institute of Production Automation (pak) at the University of Kaiserslautern a comparative investigation was carried out for alternative pointing devices like mouse, mousepad, mousebutton, mousestick, trackball, joystick, touchscreen, digitizing tablet and keyboard to determine their industrial suitability. This paper presents the methods of investigation and the most important results. The known Fitts' law model is mainly used in the field of HCl for office applications in order to evaluate interaction devices. This paper presents the new method DEVICE and is applied in the field of HMI for the evaluation of pointing devices. Tests with DEVICE and Fitts' method were conducted with machine operators under industrial environments to determine the suitability of thirty different pointing devices. The comparison between DEVICE and Fitts' law model shows that the results of certain partial tests correlate with each other. DEVICE can be used as substitute for Fitts' law model and offers additional parameters such as e.g. error rates and pointing deviation

  3. Analysis of medical device materials with the local electrode atom probe

    International Nuclear Information System (INIS)

    Goodman, S.L.; Mengelt, T.J.; Ali, M.; Ulfig, R.M.; Martens, R.M.; Kelly, T.F.; Kostrna, S.L.P.; Kostrna, M.S.; Carmichael, W.J.

    2004-01-01

    Full text: As medical technology advances towards microsurgical and minimally invasive techniques, there is a drive to produce ever-smaller devices that demand higher material performance and hence enhanced nano and micro-scale control of material structure. These devices are made from stainless steel alloys, Nitinol, titanium, CoCrMo, and non-metals such as pyrolytic carbon and silicon. These applications are made possible due to suitable physical and mechanical properties, good corrosion resistance in biological environments, reasonable biocompatibility, and good manufacturability. With respect to the metals, the nano-structure and composition of the material surface, typically an oxide, is especially critical since biological responses and corrosion occur at the material-environment interface. Thus, there is an increasing need to understand the 3-D structure and composition of metallic biomaterials at the atomic scale. Three-dimensional atom probe microscopy can uniquely provide such atomic-level structural information. In the present study several of these medical device materials were examined. These include a 316L stainless steel alloy which is widely used in implanted spinal fixation devices, bone screws, cardiovascular and neurological stents, a cast CoCrMo acetabular hip cup of a Cormet metal-on-metal Hip Resurfacing System (Corin Group, Cirencester, England) that was rejected for clinical use, Nitinol wires specimens such as are used for stents and guide wires, and low temperature pyrolytic carbon as used in clinical heart valve prosthetics. (author)

  4. 76 FR 67463 - Pediatric Medical Devices; Public Workshop; Request for Comments

    Science.gov (United States)

    2011-11-01

    ... use, existing scientific research data to determine pediatric effectiveness based on a similar course... research data, and C. The methods to overcome the pitfalls and data gaps, including statistical approaches... announcing a public workshop entitled ``Using Scientific Research Data to Support Pediatric Medical Device...

  5. HEALTH TECHNOLOGY ASSESSMENT OF MEDICAL DEVICES IN EUROPE: PROCESSES, PRACTICES, AND METHODS.

    Science.gov (United States)

    Fuchs, Sabine; Olberg, Britta; Panteli, Dimitra; Busse, Reinhard

    2016-01-01

    To review and compare current Health Technology Assessment (HTA) activities for medical devices (MDs) across European HTA institutions. A comprehensive approach was adopted to identify institutions involved in HTA in European countries. We systematically searched institutional Web sites and other online sources by using a structured tool to extract information on the role and link to decision making, structure, scope, process, methodological approach, and available HTA reports for each included institution. Information was obtained from eighty-four institutions, forty-seven of which were analyzed. Fifty-four methodological documents from twenty-three agencies in eighteen countries were identified. Only five agencies had separate documents for the assessment of MDs. A few agencies made separate provisions for the assessment of MDs in their general methods. The amount of publicly available HTA reports on MDs varied by device category and agency remit. Despite growing consensus on their importance and international initiatives, such as the EUnetHTA Core Model®, specific tools for the assessment of MDs are rarely developed and implemented at the national level. Separate additional signposts incorporated in existing general methods guides may be sufficient for the evaluation of MDs.

  6. Approval of devices and facilities using ionizing radiations for medical purposes

    International Nuclear Information System (INIS)

    1977-01-01

    This Order made by the Ministers of Health and Social Security, Agriculture and Labour amends a previous Decree of 23 April 1969 in particular concerning the classification of medical or dental radiodiagnostic devices subject to approval. The technical conditions to be complied with for such devices and facilities have also been amended. Finally, it is provided that, as regards facilities with heavy equipment subject to licensing (Act of 31 December 1970), approval is subject to compliance with the licensing conditions and is requested together with the application for a licence. (NEA) [fr

  7. A balancing act: a phenomenological exploration of medical students' experiences of using mobile devices in the clinical setting.

    Science.gov (United States)

    Rashid-Doubell, F; Mohamed, S; Elmusharaf, K; O'Neill, C S

    2016-05-03

    The aims of this study were to describe the experiences of senior students using mobile devices in a clinical setting while learning and interacting with clinical teachers, patients and each other, and to identify challenges that facilitated or impeded the use of such devices in the hospital. Interpretative phenomenology was chosen to guide our enquiry. Semi-structured interviews were conducted to examine the experiences of five senior medical students using mobile devices in the clinical setting. Senior medical students at an international medical school in the Middle East. Three main themes emerged from the data analysis: learning; professional identity and transitioning from student to doctor. The findings showed that using mobile devices in the clinical area as a learning tool was not a formalised process. Rather, it was opportunistic learning at the bedside and on occasion a source of distraction from clinical teaching. Students needed to negotiate relationships between themselves, the clinical teacher and patients in order to ensure that they maintained an acceptable professional image. Participants experienced and negotiated the change from student to doctor making them mindful of using their devices at the bedside. Mobile devices are part of daily life for a medical student and there is a need to adapt medical education in the clinical setting, to allow the students to use their devices in a sensitive manner. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  8. Dynamics of device innovation: implications for assessing value.

    Science.gov (United States)

    Gelijns, Annetine C; Russo, Mark J; Hong, Kimberly N; Brown, Lawrence D; Ascheim, Deborah D; Moskowitz, Alan J

    2013-10-01

    In recent years, there has been growing interest in evaluating the health and economic impact of medical devices. Payers increasingly rely on cost-effectiveness analyses in making their coverage decisions, and are adopting value-based purchasing initiatives. These analytic approaches, however, have been shaped heavily by their use in the pharmaceutical realm, and are ill-adapted to the medical device context. This study focuses on the development and evaluation of left ventricular assist devices (LVADs) to highlight the unique challenges involved in the design and conduct of device trials compared with pharmaceuticals. Devices are moving targets characterized by a much higher degree of post-introduction innovation and "learning by using" than pharmaceuticals. The cost effectiveness ratio of left ventricular assist devices for destination therapy, for example, decreased from around $600,000 per life year saved based on results from the pivotal trial to around $100,000 within a relatively short time period. These dynamics pose fundamental challenges to the evaluation enterprise as well as the policy-making world, which this paper addresses.

  9. Medical diagnostics with mobile devices: Comparison of intrinsic and extrinsic sensing.

    Science.gov (United States)

    Kwon, L; Long, K D; Wan, Y; Yu, H; Cunningham, B T

    2016-01-01

    We review the recent development of mobile detection instruments used for medical diagnostics, and consider the relative advantages of approaches that utilize the internal sensing capabilities of commercially available mobile communication devices (such as smartphones and tablet computers) compared to those that utilize a custom external sensor module. In this review, we focus specifically upon mobile medical diagnostic platforms that are being developed to serve the need in global health, personalized medicine, and point-of-care diagnostics. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. EM-GE-5 Regulation. Standard for the first-rate application clinical practices in the execution of the clinical investigations for medical teams' evaluation

    International Nuclear Information System (INIS)

    2015-01-01

    This guide has the following objectives: a) To guide methodologically the implementation of Good Clinical Practice for the execution of clinical research with medical devices that need to be evaluated, in addition to the Regulation E R-6. Requirements for the Conduct of Clinical Trials for Medical Devices , b) Provide the fundamental aspects to be taken into count for quality control to clinical investigations.

  11. 77 FR 52742 - Public Meeting-Strengthening the National Medical Device Postmarket Surveillance System; Request...

    Science.gov (United States)

    2012-08-30

    ... Contact Person) no later than September 5, 2012. No commercial or promotional material will be permitted... develop and implement a comprehensive medical device postmarket surveillance strategy to collect, analyze... implementing this strategy, FDA is holding a public meeting to discuss the current and future state of medical...

  12. Assurance of Medical Device Quality with Quality Management System: An Analysis of Good Manufacturing Practice Implementation in Taiwan

    Directory of Open Access Journals (Sweden)

    Tzu-Wei Li

    2015-01-01

    Full Text Available The implementation of an effective quality management system has always been considered a principal method for a manufacturer to maintain and improve its product and service quality. Globally many regulatory authorities incorporate quality management system as one of the mandatory requirements for the regulatory control of high-risk medical devices. The present study aims to analyze the GMP enforcement experience in Taiwan between 1998 and 2013. It describes the regulatory implementation of medical device GMP requirement and initiatives taken to assist small and medium-sized enterprises in compliance with the regulatory requirement. Based on statistical data collected by the competent authority and industry research institutes, the present paper reports the growth of Taiwan local medical device industry after the enforcement of GMP regulation. Transition in the production, technologies, and number of employees of Taiwan medical device industry between 1998 and 2013 provides the competent authorities around the world with an empirical foundation for further policy development.

  13. Potential negative consequences of non-consented switch of inhaled medications and devices in asthma patients.

    Science.gov (United States)

    Björnsdóttir, U S; Gizurarson, S; Sabale, U

    2013-09-01

    Asthma requires individually tailored and careful management to control and prevent symptoms and exacerbations. Selection of the most appropriate treatment is dependent on both the choice of drugs and inhaler device; however, financial pressures may result in patients being switched to alternative medications and devices in an attempt to reduce costs. This review aimed to examine the published literature in order to ascertain whether switching a patient's asthma medications or device negatively impacts clinical and economic outcomes. A literature search of MEDLINE (2001-13 September 2011) was conducted to identify English-language articles focused on the direct impact of switching medications and inhaler devices and switching from fixed-dose combination to monocomponent therapy via separate inhalers in patients with asthma; the indirect impacts of switching were also assessed. Evidence showed that non-consented switching of medications and inhalers in patients with asthma can be associated with a range of negative outcomes, at both individual and organisational levels. Factors that reduce adherence may lead to compromised symptom control resulting in increased healthcare resource utilisation and poorer patient quality of life. The consequences of a non-consented switch should be weighed carefully against arguments supporting an inhaler switch without the patient's consent for non-medical/budgetary reasons, such as potential reductions in initial acquisition costs, which may be associated with subsequent additional healthcare needs. Given the increasing pressure for reduced costs and efficient allocation of limited healthcare resources, an additional investment in ensuring high medication adherence may lead to greater savings due to a potentially decreased demand for healthcare services. In contrast, savings achieved in acquisition costs may result in a greater net loss due to increased healthcare consumption caused by decreased asthma control. © 2013 The Authors

  14. The Development of 1Balance: A Connected Medical Device for Measuring Human Balance

    Directory of Open Access Journals (Sweden)

    Heikki Sjöman

    2018-05-01

    Full Text Available Prototyping (iterative loops of design–build–test is a proven method of efficiently developing new products. Developing products not only quickly, but that are also fit for purpose, implies engaging the end users and iterating the technology at hand. However, there is currently little research on how engineering design can approach developing connected devices. The purpose of this paper is to distinguish and discuss design approaches that are suitable for connected devices. Internet of Things devices consist of both the physical products themselves and the data that is coming out of the products, which we define as the external and internal data, respectively. They both can be prototyped separately, but since the data acquired can influence the design of the device and vice versa, we propose to link these two together in the product development process. This issue becomes more apparent when designing networks of sensors, e.g., for complex artificial intelligence (AI databases. We explain the principle by describing the development of 1Balance through six different prototypes for human balance measurement. Technologically quantifying balance is an underused approach for objectively evaluating the state of a human’s performance. The authors have developed a mobile application for monitoring balance as a physiological signal (amount of sway via a compact wireless inertial measurement unit (IMU sensor strapped to the body of the subject for the duration of the measurement. We describe the design process for developing this connected medical device, as well as how the acquired data was used to improve the design of the product. In conclusion, we propose conceptually connecting the external and internal data prototyping loops.

  15. Engaging with economic evaluation methods: insights from small and medium enterprises in the UK medical devices industry after training workshops

    Directory of Open Access Journals (Sweden)

    Craven Michael P

    2012-09-01

    Full Text Available Abstract Background With increased governmental interest in value assessment of technologies and where medical device manufacturers are finding it increasingly necessary to become more familiar with economic evaluation methods, the study sought to explore the levels of health economics knowledge within small and medium-sized enterprises (SMEs and to scope strategies they employ to demonstrate the value of their products to purchasers. Methods A short questionnaire was completed by participants attending one of five workshops on product development in the medical device sector that took place in England between 2007 and 2011. From all responses obtained, a large proportion of participants were based in SMEs (N = 43, and these responses were used for the analysis. Statistical analysis using non-parametric tests was performed on questions with approximately interval scales. Qualitative data from participant responses were analysed to reveal emerging themes. Results The questionnaire results revealed that 60% of SME participants (mostly company directors or managers, including product or project managers rated themselves as having low or no knowledge of health economics prior to the workshops but the rest professed at least medium knowledge. Clinical trials and cost analyses or cost-effectiveness studies were the most highly cited means by which SMEs aim to demonstrate value of products to purchasers. Purchasers were perceived to place most importance on factors of safety, expert opinion, cost-effectiveness and price. However many companies did not utilise formal decision-making tools to prioritise these factors. There was no significant dependence of the use of decision-making tools in general with respect to professed knowledge of health economics methods. SMEs did not state a preference for any particular aspect of potential value when deciding whether to develop a product. A majority of SMEs stated they would use a health economics tool

  16. Engaging with economic evaluation methods: insights from small and medium enterprises in the UK medical devices industry after training workshops.

    Science.gov (United States)

    Craven, Michael P; Allsop, Matthew J; Morgan, Stephen P; Martin, Jennifer L

    2012-09-03

    With increased governmental interest in value assessment of technologies and where medical device manufacturers are finding it increasingly necessary to become more familiar with economic evaluation methods, the study sought to explore the levels of health economics knowledge within small and medium-sized enterprises (SMEs) and to scope strategies they employ to demonstrate the value of their products to purchasers. A short questionnaire was completed by participants attending one of five workshops on product development in the medical device sector that took place in England between 2007 and 2011. From all responses obtained, a large proportion of participants were based in SMEs (N = 43), and these responses were used for the analysis. Statistical analysis using non-parametric tests was performed on questions with approximately interval scales. Qualitative data from participant responses were analysed to reveal emerging themes. The questionnaire results revealed that 60% of SME participants (mostly company directors or managers, including product or project managers) rated themselves as having low or no knowledge of health economics prior to the workshops but the rest professed at least medium knowledge. Clinical trials and cost analyses or cost-effectiveness studies were the most highly cited means by which SMEs aim to demonstrate value of products to purchasers. Purchasers were perceived to place most importance on factors of safety, expert opinion, cost-effectiveness and price. However many companies did not utilise formal decision-making tools to prioritise these factors. There was no significant dependence of the use of decision-making tools in general with respect to professed knowledge of health economics methods. SMEs did not state a preference for any particular aspect of potential value when deciding whether to develop a product. A majority of SMEs stated they would use a health economics tool. Research and development teams or marketing and sales

  17. [Evaluation of two closed-system drug transfer device in the antineoplastic drug elaboration process].

    Science.gov (United States)

    Gómez-Álvarez, Sandra; Porta-Oltra, Begoña; Hernandez-Griso, Marta; Pérez-Labaña, Francisca; Climente-Martí, Mónica

    2016-01-01

    to assess the impact of two closed-system drug transfer device on the local and environmental contamination and preparation times in the process of preparation of parenteral chemotherapy compared to the standard system. prospective observational study. Two different closed- systems providers, Care Fusion® and Icu Medical®, were compared to standard preparation. 15 nurses of Pharmacy Department prepared 5 preparations each one, one with the standard procedure and four using closed-systems. To evaluate the contamination, a fluorescein solution 0.5% was prepared. Two kind of contamination were evaluated, local (three points connection: closed-system connect vial, syringe and final infusion bags) and environmental (gloves and countertop). Percentage of contaminated preparations was obtained in each one. Time taken by each nurse in each preparation was recorded. 75 preparations were prepared. Local contamination was reduced 21% and 75% in closed-system Icu Medical® and Care Fusion® respectively. Care Fusion® closed system, local contamination was significantly lower than the standard system to the vial, syringe and final package, while Icu Medical® closed-systems only was significantly lower in the connection to the vial. Time of preparation was increased significantly with the use of closed-system between 23.4 and 30.5 seconds. both closed-systems drug transfer device have shown an improvement in contamination than the use of the standard system. However, preparation time has been significantly increased with the use of both systems. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  18. The effects of cosmic radiation on implantable medical devices

    International Nuclear Information System (INIS)

    Bradley, P.

    1996-01-01

    Metal oxide semiconductor (MOS) integrated circuits, with the benefits of low power consumption, represent the state of the art technology for implantable medical devices. Three significant sources of radiation are classified as having the ability to damage or alter the behavior of implantable electronics; Secondary neutron cosmic radiation, alpha particle radiation from the device packaging and therapeutic doses(up to 70 Gγ) of high energy radiation used in radiation oncology. The effects of alpha particle radiation from the packaging may be eliminated by the use of polyimide or silicone rubber die coatings. The relatively low incidence of therapeutic radiation incident on an implantable device and the use of die coating leaves cosmic radiation induced secondary neutron single event upset (SEU) as the main pervasive ionising radiation threat to the reliability of implantable devices. A theoretical model which predicts the susceptibility of a RAM cell to secondary neutron cosmic radiation induced SEU is presented. The model correlates well within the statistical uncertainty associated with both the theoretical and field estimate. The predicted Soft Error Rate (SER) is 4.8 x l0 -12 upsets/(bit hr) compared to an observed upset rate of 8.5 x 10 -12 upsets/(bit hr) from 20 upsets collected over a total of 284672 device days. The predicted upset rate may increase by up to 20% when consideration is given to patients flying in aircraft The upset rate is also consistent with the expected geographical variations of the secondary cosmic ray neutron flux, although insufficient upsets precluded a statistically significant test. This is the first clinical data set obtained indicating the effects of cosmic radiation on implantable devices. Importantly, it may be used to predict the susceptibility of future to the implantable device designs to the effects of cosmic radiation

  19. ISO 13485: a complete guide to quality management in the medical device industry

    National Research Council Canada - National Science Library

    Abuhav, Itay

    2012-01-01

    .... Written by an experienced industry professional, this practical book provides a complete guide to the ISO 13485 standard certification for medical device manufacturing in terms of quality control...

  20. Evaluation of ExPress glaucoma filtration device in Indian patients with advanced glaucoma

    Directory of Open Access Journals (Sweden)

    Dewang Angmo

    2015-01-01

    Full Text Available ExPress glaucoma filtration device (GFD has recently become available in India as a surgical option for glaucoma patients. We retrospectively evaluated the outcome of ExPress GFD in 12 eyes with advanced glaucoma with intraocular pressures (IOPs not controlled on maximal tolerable medical therapy. The mean preoperative IOP of 29.58 ± 7.13 mmHg decreased to 17.0 ± 2.67 and 17.40 ± 0.89 mmHg at 6 and 12 months after surgery. Absolute success (IOP ≤ 18 mmHg, with no additional glaucoma medications was achieved in eight cases (66.7% and qualified success (IOP ≤ 18 mmHg, with additional glaucoma medications in two cases (16.7% at 1-year after surgery. Early intervention was needed in 4 patients; two underwent anterior chamber reformation while the other two required needling. Two patients required resurgery. There was no significant change in the best corrected visual acuity postoperatively (P = 0.37. ExPress GFD does not seem to offer a benefit over standard trabeculectomy in patients with advanced glaucomatous disease in terms of IOP control or complication rate. However, due to the small sample size with a heterogeneous mixture of primary and secondary glaucoma′s, we await further studies with a larger sample size and long-term follow-up, to see how the device performs.

  1. Evaluation of ExPress glaucoma filtration device in Indian patients with advanced glaucoma.

    Science.gov (United States)

    Angmo, Dewang; Sharma, Reetika; Temkar, Shreyas; Dada, Tanuj

    2015-05-01

    ExPress glaucoma filtration device (GFD) has recently become available in India as a surgical option for glaucoma patients. We retrospectively evaluated the outcome of ExPress GFD in 12 eyes with advanced glaucoma with intraocular pressures (IOPs) not controlled on maximal tolerable medical therapy. The mean preoperative IOP of 29.58 ± 7.13 mmHg decreased to 17.0 ± 2.67 and 17.40 ± 0.89 mmHg at 6 and 12 months after surgery. Absolute success (IOP ≤ 18 mmHg, with no additional glaucoma medications) was achieved in eight cases (66.7%) and qualified success (IOP ≤ 18 mmHg, with additional glaucoma medications) in two cases (16.7%) at 1-year after surgery. Early intervention was needed in 4 patients; two underwent anterior chamber reformation while the other two required needling. Two patients required resurgery. There was no significant change in the best corrected visual acuity postoperatively (P = 0.37). ExPress GFD does not seem to offer a benefit over standard trabeculectomy in patients with advanced glaucomatous disease in terms of IOP control or complication rate. However, due to the small sample size with a heterogeneous mixture of primary and secondary glaucoma's, we await further studies with a larger sample size and long-term follow-up, to see how the device performs.

  2. Reliability evaluation programmable logic devices

    International Nuclear Information System (INIS)

    Srivani, L.; Murali, N.; Thirugnana Murthy, D.; Satya Murty, S.A.V.

    2014-01-01

    Programmable Logic Devices (PLD) are widely used as basic building modules in high integrity systems, considering their robust features such as gate density, performance, speed etc. PLDs are used to implement digital design such as bus interface logic, control logic, sequencing logic, glue logic etc. Due to semiconductor evolution, new PLDs with state-of-the-art features are arriving to the market. Since these devices are reliable as per the manufacturer's specification, they were used in the design of safety systems. But due to their reduced market life, the availability of performance data is limited. So evaluating the PLD before deploying in a safety system is very important. This paper presents a survey on the use of PLDs in the nuclear domain and the steps involved in the evaluation of PLD using Quantitative Accelerated Life Testing. (author)

  3. Factors that influence the recognition, reporting and resolution of incidents related to medical devices and other healthcare technologies: a systematic review.

    Science.gov (United States)

    Polisena, Julie; Gagliardi, Anna; Urbach, David; Clifford, Tammy; Fiander, Michelle

    2015-03-29

    Medical devices have improved the treatment of many medical conditions. Despite their benefit, the use of devices can lead to unintended incidents, potentially resulting in unnecessary harm, injury or complications to the patient, a complaint, loss or damage. Devices are used in hospitals on a routine basis. Research to date, however, has been primarily limited to describing incidents rates, so the optimal design of a hospital-based surveillance system remains unclear. Our research objectives were twofold: i) to explore factors that influence device-related incident recognition, reporting and resolution and ii) to investigate interventions or strategies to improve the recognition, reporting and resolution of medical device-related incidents. We searched the bibliographic databases: MEDLINE, Embase, the Cochrane Central Register of Controlled Trials and PsycINFO database. Grey literature (literature that is not commercially available) was searched for studies on factors that influence incident recognition, reporting and resolution published and interventions or strategies for their improvement from 2003 to 2014. Although we focused on medical devices, other health technologies were eligible for inclusion. Thirty studies were included in our systematic review, but most studies were concentrated on other health technologies. The study findings indicate that fear of punishment, uncertainty of what should be reported and how incident reports will be used and time constraints to incident reporting are common barriers to incident recognition and reporting. Relevant studies on the resolution of medical errors were not found. Strategies to improve error reporting include the use of an electronic error reporting system, increased training and feedback to frontline clinicians about the reported error. The available evidence on factors influencing medical device-related incident recognition, reporting and resolution by healthcare professionals can inform data collection and

  4. Outsourcing versus in-house maintenance of medical devices: a longitudinal, empirical study.

    Science.gov (United States)

    Miguel-Cruz, Antonio; Rios-Rincón, Adriana; Haugan, Gregory L

    2014-03-01

    To determine what factors have a significant influence on the performance of medical device maintenance outsourcing, and to determine how the performance of external governance structures differs depending on whether a hospital is private or public. This was a longitudinal study of 590 maintenance transactions at 20 hospitals in Bogotá, Colombia, involving 764 medical devices and 72 maintenance service providers. Maintenance performance data (i.e., turn-around time in hours; TAT) for the service providers (either in-house or outsourced) were primarily collected over a 20-month period, from December 2009-August 2011, by means of a monitoring procedure; then, a hazards model was run. The availability of specific repair parts, in-stock, in the city in which the medical devices were located, had a positive impact on the performance of both internal and external governance structures. Online service also had a positive impact on both, with a stronger positive impact on the performance of internal governance than on that of external governance. For transactions governed by external structures, better performance was seen in private hospitals than in public ones. In public health institutions, internal governance showed better performance than external governance. Both internal and external governance structures showed better performance in private healthcare institutions than in public ones. In public health institutions, internal governance shows better performance than external governance; this suggests that healthcare managers should reconsider the trend to eliminate in-house maintenance service staff in public healthcare institutions.

  5. Clinical Evaluation of a Novel Intrarectal Device for Management of Fecal Incontinence in Bedridden Patients.

    Science.gov (United States)

    Singh, Sandeep; Bhargava, Balram; Vasantha, Padma; Bhatia, Rohit; Sharma, Hanish; Pal, Sujoy; Sahni, Peush; Makharia, Govind K

    The primary objective of the study was to evaluate the safety and efficacy of a stool management kit (SMK) for containment of fecal incontinence in hospitalized bedridden patients. A single-group quasi-experimental study. Twenty bedridden adults who had at least 1 episode of fecal incontinence in the prior 24 hours participated in the study. The study setting was the neurological unit of the All India Institute of Medical Sciences in New Delhi, India. The study was carried out in 2 phases. The device was placed in situ for up to 24 hours in 10 patients during phase I of the study and up to 120 hours in an additional 10 patients during phase II. Participants were assessed for anorectal injury and peripheral device leakage on a 4- to 6-hourly basis. Sigmoidoscopy was performed to evaluate for any mucosal trauma or alteration of anorectal pathology after retrieval of the device. The device was successfully placed in all patients following the first attempt to place the device; 80% of patients retained the device until planned removal. The SMK diverted fecal matter without anal leakage in 174 (93.5%) out of 186 assessment points in a group of 20 patients. The devices remained in situ for 21 ± 0.2 and 84.5 ± 38.9 hours during phase I and phase II, respectively. None experienced anorectal bleeding, sphincter injury, or mucosal ulceration with device usage. Post-device sigmoidoscopy revealed erythema at the site of diverter placement in 2 participants. Study findings suggest that the SMK successfully diverted liquid to semiformed fecal exudate without peripheral device leakage in 93.5% of bedridden patients. No serious adverse events occurred. Additional research is needed to compare its effectiveness with that of currently available intrarectal balloon devices.

  6. A flexible super-capacitive solid-state power supply for miniature implantable medical devices.

    Science.gov (United States)

    Meng, Chuizhou; Gall, Oren Z; Irazoqui, Pedro P

    2013-12-01

    We present a high-energy local power supply based on a flexible and solid-state supercapacitor for miniature wireless implantable medical devices. Wireless radio-frequency (RF) powering recharges the supercapacitor through an antenna with an RF rectifier. A power management circuit for the super-capacitive system includes a boost converter to increase the breakdown voltage required for powering device circuits, and a parallel conventional capacitor as an intermediate power source to deliver current spikes during high current transients (e.g., wireless data transmission). The supercapacitor has an extremely high area capacitance of ~1.3 mF/mm(2), and is in the novel form of a 100 μm-thick thin film with the merit of mechanical flexibility and a tailorable size down to 1 mm(2) to meet various clinical dimension requirements. We experimentally demonstrate that after fully recharging the capacitor with an external RF powering source, the supercapacitor-based local power supply runs a full system for electromyogram (EMG) recording that consumes ~670 μW with wireless-data-transmission functionality for a period of ~1 s in the absence of additional RF powering. Since the quality of wireless powering for implantable devices is sensitive to the position of those devices within the RF electromagnetic field, this high-energy local power supply plays a crucial role in providing continuous and reliable power for medical device operations.

  7. 47 CFR 95.1121 - Specific requirements for wireless medical telemetry devices operating in the 1395-1400 and 1427...

    Science.gov (United States)

    2010-10-01

    ... wireless medical telemetry devices operating in the 1395-1400 and 1427-1432 MHz bands. Due to the critical... 47 Telecommunication 5 2010-10-01 2010-10-01 false Specific requirements for wireless medical telemetry devices operating in the 1395-1400 and 1427-1432 MHz bands. 95.1121 Section 95.1121...

  8. 77 FR 59667 - NIJ Evaluation of Through-Wall Sensor Devices

    Science.gov (United States)

    2012-09-28

    ... Through-Wall Sensor Devices AGENCY: National Institute of Justice, DOJ. ACTION: Notice of NIJ evaluation of through-wall sensor devices. SUMMARY: The National Institute of Justice (NIJ) is soliciting interest in supplying through-wall sensor devices for participation in an evaluation by the NIJ Sensor...

  9. Virtual worlds are an innovative tool for medical device training in a simulated environment.

    Science.gov (United States)

    Patel, Vishal; Lee, Henry; Taylor, Dave; Aggarwal, Rajesh; Kinross, James; Darzi, Ara

    2012-01-01

    Medical infusion devices are an integral component within the delivery of healthcare management. The aim of this study was to develop a training simulation in the virtual world of Second Life for the management of adverse events associated with infusion devices. Forty nurses were subsequently recruited to participate within the simulation and assess its feasibility.

  10. Evaluation of the medical devices benchmark materials in the controlled human patch testing and in the RhE in vitro skin irritation protocol.

    NARCIS (Netherlands)

    Kandárová, Helena; Bendova, Hana; Letasiova, Silvia; Coleman, Kelly P; De Jong, Wim H; Jírova, Dagmar

    2018-01-01

    Several irritants were used in the in vitro irritation medical device round robin. The objective of this study was to verify their irritation potential using the human patch test (HPT), an in vitro assay, and in vivo data. The irritants were lactic acid (LA), heptanoic acid (HA), sodium dodecyl

  11. In situ formation of antimicrobial silver nanoparticles and the impregnation of hydrophobic polycaprolactone matrix for antimicrobial medical device applications.

    Science.gov (United States)

    Tran, Phong A; Hocking, Dianna M; O'Connor, Andrea J

    2015-02-01

    Bacterial infection associated with medical devices remains a challenge to modern medicine as more patients are being implanted with medical devices that provide surfaces and environment for bacteria colonization. In particular, bacteria are commonly found to adhere more preferably to hydrophobic materials and many of which are used to make medical devices. Bacteria are also becoming increasingly resistant to common antibiotic treatments as a result of misuse and abuse of antibiotics. There is an urgent need to find alternatives to antibiotics in the prevention and treatment of device-associated infections world-wide. Silver nanoparticles have emerged as a promising non-drug antimicrobial agent which has shown effectiveness against a wide range of both Gram-negative and Gram-positive pathogen. However, for silver nanoparticles to be clinically useful, they must be properly incorporated into medical device materials whose wetting properties could be detrimental to not only the incorporation of the hydrophilic Ag nanoparticles but also the release of active Ag ions. This study aimed at impregnating the hydrophobic polycaprolactone (PCL) polymer, which is a FDA-approved polymeric medical device material, with hydrophilic silver nanoparticles. Furthermore, a novel approach was employed to uniformly, incorporate silver nanoparticles into the PCL matrix in situ and to improve the release of Ag ions from the matrix so as to enhance antimicrobial efficacy. Copyright © 2014. Published by Elsevier B.V.

  12. Reducing hospital noise: a review of medical device alarm management.

    Science.gov (United States)

    Konkani, Avinash; Oakley, Barbara; Bauld, Thomas J

    2012-01-01

    Increasing noise in hospital environments, especially in intensive care units (ICUs) and operating rooms (ORs), has created a formidable challenge for both patients and hospital staff. A major contributing factor for the increasing noise levels in these environments is the number of false alarms generated by medical devices. This study focuses on discovering best practices for reducing the number of false clinical alarms in order to increase patient safety and provide a quiet environment for both work and healing. The researchers reviewed Pub Med, Web of Knowledge and Google Scholar sources to obtain original journal research and review articles published through January 2012. This review includes 27 critically important journal articles that address different aspects of medical device alarms management, including the audibility, identification, urgency mapping, and response time of nursing staff and different solutions to such problems. With current technology, the easiest and most direct method for reducing false alarms is to individualize alarm settings for each patient's condition. Promoting an institutional culture change that emphasizes the importance of individualization of alarms is therefore an important goal. Future research should also focus on the development of smart alarms.

  13. 77 FR 26769 - Educational Forum on Medical Device Reporting, Complaint Files, and Recalls, Corrections, and...

    Science.gov (United States)

    2012-05-07

    ... Device Quality Systems Regulation (QSR) to the regulated industry, particularly small businesses. DATES... registration fee will be used to offset expenses of hosting the event including continental breakfast, lunch... interest in the topics discussed from small medical device manufacturers in the Dallas District area. This...

  14. Clinical protocol levels are required in laboratory animal surgery when using medical devices: experiences with ureteral replacement surgery in goats

    OpenAIRE

    de Jonge, Paul K. J. D.; Sloff, Marije; Janke, Heinz P.; Kortmann, Barbara B. M.; de Gier, Robert P. E.; Geutjes, Paul J.; Oosterwijk, Egbert; Feitz, Wout F. J.

    2017-01-01

    It is common to test medical devices in large animal studies that are or could also be used in humans. In this short report we describe the use of a ureteral J-stent for the evaluation of biodegradable tubular constructs for tissue reconstruction, and the regeneration of ureters in Saanen goats. Similarly to a previous study in pigs, the ureteral J-stent was blindly inserted until some resistance was met. During evaluation of the goats after three months, perforation of the renal cortex by th...

  15. Navigating conflicts of interest for the medical device entrepreneur.

    Science.gov (United States)

    Donovan, Aine; Kaplan, Aaron V

    2012-01-01

    The past fifty years has witnessed dramatic progress in the understanding and treatment of patients suffering from cardiovascular disease leading to symptomatic relief and impressive increases in longevity. These advances have been due in large part to the development, study and implementation of new technology. Within interventional cardiology in particular, these advances have been driven by the availability of new technology in the form of medical devices. Successful device development efforts require close collaboration among basic scientist, clinician-inventors/entrepreneurs, clinician-investigators and corporations. Though the role of the clinician is central to this process, these activities present important conflicts-of-interest (COIs). The purpose of this paper is to 1) characterize these conflicts, 2) provide a context from which to approach their management and 3) recommend management strategies. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. 78 FR 950 - Medical Devices; Availability of Safety and Effectiveness Summaries for Premarket Approval...

    Science.gov (United States)

    2013-01-07

    ..., FDA- 2012-M-0965, FDA-2012-M-0968, FDA-2012-M-1011, and FDA-2012-M-1013] Medical Devices; Availability.... Glucose Monitoring System (TGMS). P000008/S017, FDA-2012-M-1013.. Allergan, Inc..... LAP-BAND \\TM\\ February 16, 2011. Adjustable Gastric Banding System. P100049, FDA-2012-M-0893....... Torax Medical, Inc...

  17. Security and Privacy Qualities of Medical Devices: An Analysis of FDA Postmarket Surveillance

    OpenAIRE

    Ransford, Benjamin; Molina-Markham, Andres; Stewart, Quinn; Fu, Kevin; Kramer, Daniel Bruce; Baker, Matthew Charles; Reynolds, Matthew R.

    2012-01-01

    Background: Medical devices increasingly depend on computing functions such as wireless communication and Internet connectivity for software-based control of therapies and network-based transmission of patients’ stored medical information. These computing capabilities introduce security and privacy risks, yet little is known about the prevalence of such risks within the clinical setting. Methods: We used three comprehensive, publicly available databases maintained by the Food and Drug Admini...

  18. Taking transition into account: designing with pre-users of medical devices

    DEFF Research Database (Denmark)

    Kelly, Janet; Matthews, Ben

    2010-01-01

    of the product. We present a case study that documents how we worked with pre-users of two different types of medical technologies: hearing aids and insulin injection devices. Pre-users are people who do not currently use these products, but who are in a life situation for which these technologies may...

  19. Corruption in the health care sector: A barrier to access of orthopaedic care and medical devices in Uganda.

    Science.gov (United States)

    Bouchard, Maryse; Kohler, Jillian C; Orbinski, James; Howard, Andrew

    2012-05-03

    Globally, injuries cause approximately as many deaths per year as HIV/AIDS, tuberculosis and malaria combined, and 90% of injury deaths occur in low- and middle- income countries. Given not all injuries kill, the disability burden, particularly from orthopaedic injuries, is much higher but is poorly measured at present. The orthopaedic services and orthopaedic medical devices needed to manage the injury burden are frequently unavailable in these countries. Corruption is known to be a major barrier to access of health care, but its effects on access to orthopaedic services is still unknown. A qualitative case study of 45 open-ended interviews was conducted to investigate the access to orthopaedic health services and orthopaedic medical devices in Uganda. Participants included orthopaedic surgeons, related healthcare professionals, industry and government representatives, and patients. Participants' experiences in accessing orthopaedic medical devices were explored. Thematic analysis was used to analyze and code the transcripts. Analysis of the interview data identified poor leadership in government and corruption as major barriers to access of orthopaedic care and orthopaedic medical devices. Corruption was perceived to occur at the worker, hospital and government levels in the forms of misappropriation of funds, theft of equipment, resale of drugs and medical devices, fraud and absenteeism. Other barriers elicited included insufficient health infrastructure and human resources, and high costs of orthopaedic equipment and poverty. This study identified perceived corruption as a significant barrier to access of orthopaedic care and orthopaedic medical devices in Uganda. As the burden of injury continues to grow, the need to combat corruption and ensure access to orthopaedic services is imperative. Anti-corruption strategies such as transparency and accountability measures, codes of conduct, whistleblower protection, and higher wages and benefits for workers could be

  20. Corruption in the health care sector: A barrier to access of orthopaedic care and medical devices in Uganda

    Directory of Open Access Journals (Sweden)

    Bouchard Maryse

    2012-05-01

    Full Text Available Abstract Background Globally, injuries cause approximately as many deaths per year as HIV/AIDS, tuberculosis and malaria combined, and 90% of injury deaths occur in low- and middle- income countries. Given not all injuries kill, the disability burden, particularly from orthopaedic injuries, is much higher but is poorly measured at present. The orthopaedic services and orthopaedic medical devices needed to manage the injury burden are frequently unavailable in these countries. Corruption is known to be a major barrier to access of health care, but its effects on access to orthopaedic services is still unknown. Methods A qualitative case study of 45 open-ended interviews was conducted to investigate the access to orthopaedic health services and orthopaedic medical devices in Uganda. Participants included orthopaedic surgeons, related healthcare professionals, industry and government representatives, and patients. Participants’ experiences in accessing orthopaedic medical devices were explored. Thematic analysis was used to analyze and code the transcripts. Results Analysis of the interview data identified poor leadership in government and corruption as major barriers to access of orthopaedic care and orthopaedic medical devices. Corruption was perceived to occur at the worker, hospital and government levels in the forms of misappropriation of funds, theft of equipment, resale of drugs and medical devices, fraud and absenteeism. Other barriers elicited included insufficient health infrastructure and human resources, and high costs of orthopaedic equipment and poverty. Conclusions This study identified perceived corruption as a significant barrier to access of orthopaedic care and orthopaedic medical devices in Uganda. As the burden of injury continues to grow, the need to combat corruption and ensure access to orthopaedic services is imperative. Anti-corruption strategies such as transparency and accountability measures, codes of conduct

  1. Corruption in the health care sector: A barrier to access of orthopaedic care and medical devices in Uganda

    Science.gov (United States)

    2012-01-01

    Background Globally, injuries cause approximately as many deaths per year as HIV/AIDS, tuberculosis and malaria combined, and 90% of injury deaths occur in low- and middle- income countries. Given not all injuries kill, the disability burden, particularly from orthopaedic injuries, is much higher but is poorly measured at present. The orthopaedic services and orthopaedic medical devices needed to manage the injury burden are frequently unavailable in these countries. Corruption is known to be a major barrier to access of health care, but its effects on access to orthopaedic services is still unknown. Methods A qualitative case study of 45 open-ended interviews was conducted to investigate the access to orthopaedic health services and orthopaedic medical devices in Uganda. Participants included orthopaedic surgeons, related healthcare professionals, industry and government representatives, and patients. Participants’ experiences in accessing orthopaedic medical devices were explored. Thematic analysis was used to analyze and code the transcripts. Results Analysis of the interview data identified poor leadership in government and corruption as major barriers to access of orthopaedic care and orthopaedic medical devices. Corruption was perceived to occur at the worker, hospital and government levels in the forms of misappropriation of funds, theft of equipment, resale of drugs and medical devices, fraud and absenteeism. Other barriers elicited included insufficient health infrastructure and human resources, and high costs of orthopaedic equipment and poverty. Conclusions This study identified perceived corruption as a significant barrier to access of orthopaedic care and orthopaedic medical devices in Uganda. As the burden of injury continues to grow, the need to combat corruption and ensure access to orthopaedic services is imperative. Anti-corruption strategies such as transparency and accountability measures, codes of conduct, whistleblower protection, and higher

  2. 3D printing for health & wealth: Fabrication of custom-made medical devices through additive manufacturing

    Science.gov (United States)

    Colpani, Alessandro; Fiorentino, Antonio; Ceretti, Elisabetta

    2018-05-01

    Additive Manufacturing (AM) differs from traditional manufacturing technologies by its ability to handle complex shapes with great design flexibility. These features make the technique suitable to fabricate customized components, particularly answering specific custom needs. Although AM mainly referred to prototyping, nowadays the interest in direct manufacturing of actual parts is growing. This article shows the application of AM within the project 3DP-4H&W (3D Printing for Health & Wealth) which involves engineers and physicians for developing pediatric custom-made medical devices to enhance the fulfilling of the patients specific needs. In the project, two types of devices made of a two-component biocompatible silicone are considered. The first application (dental field) consists in a device for cleft lip and palate. The second one (audiological field) consists in an acoustic prosthesis. The geometries of the devices are based on the anatomy of the patient that is obtained through a 3D body scan process. For both devices, two different approaches were planned, namely direct AM and indirect Rapid Tooling (RT). In particular, direct AM consists in the FDM processing of silicone, while RT consists in molds FDM fabrication followed by silicone casting. This paper presents the results of the RT method that is articulated in different phases: the acquisition of the geometry to be realized, the design of the molds taking into account the casting feasibility (as casting channel, vents, part extraction), the realization of molds produced through AM, molds surface chemical finishing, pouring and curing of the silicone. The fabricated devices were evaluated by the physicians team that confirmed the effectiveness of the proposed procedure in fabricating the desired devices. Moreover, the procedure can be used as a general method to extend the range of applications to any custom-made device for anatomic districts, especially where complex shapes are present (as tracheal or

  3. Antimicrobial treatment of polymeric medical devices by silver nanomaterials and related technology

    Czech Academy of Sciences Publication Activity Database

    Polívková, A.; Hubáček, Tomáš; Staszek, M.; Švorčík, V.; Siegel, J.

    2017-01-01

    Roč. 18, č. 2 (2017), č. článku 419. E-ISSN 1422-0067 Institutional support: RVO:60077344 Keywords : antimicrobials * medical devices * nanostructures * polymers * modification Subject RIV: JJ - Other Materials OBOR OECD: Materials engineering Impact factor: 3.226, year: 2016

  4. Evaluation of ExPress glaucoma filtration device in Indian patients with advanced glaucoma

    OpenAIRE

    Angmo, Dewang; Sharma, Reetika; Temkar, Shreyas; Dada, Tanuj

    2015-01-01

    ExPress glaucoma filtration device (GFD) has recently become available in India as a surgical option for glaucoma patients. We retrospectively evaluated the outcome of ExPress GFD in 12 eyes with advanced glaucoma with intraocular pressures (IOPs) not controlled on maximal tolerable medical therapy. The mean preoperative IOP of 29.58 ± 7.13 mmHg decreased to 17.0 ± 2.67 and 17.40 ± 0.89 mmHg at 6 and 12 months after surgery. Absolute success (IOP ≤ 18 mmHg, with no additional glaucoma medicat...

  5. Risiken und Nebenwirkungen der Integration medizinischer Software in klinische IT-Strukturen – Erlanger Memorandum [Software as a medical device – side effects when applying the new European regulation on medical devices for IT products

    Directory of Open Access Journals (Sweden)

    Kaiser, J.

    2012-12-01

    Full Text Available [english] European medical device regulations have been altered to cover pure software applications as well. They now may be classified as a medical device if used for medical diagnostics and/or medical treatment. Slowly, these regulations are being implemented into national law of the EEC member states, for example into the German MPG (Medical Product Law.For some software applications such as Picture Archiving and Communication systems (PACS a classification as medical device is – at least for parts of it – routine today, ruling e.g. the quality of medical monitor screens for assessment of x-ray pictures. For software applications such as patient data management systems (PDMS, electronic health records (EHR, laboratory information systems and similar systems this was not the case so far. This paper deals with the consequences which may arise if a PDMS used on intensive care units or even an EHR is now classified as a medical device, e.g. because it is able to deliver intelligent composite views on laboratory data, medical data, and treatment information to support diagnostic assessment or treatment advice.Modern clinical information systems, PDMS and EHR support the user with medical information and clinical decision support (CDSS. So there is doubt that they are used for diagnostics and/or treatment. Medical device regulations distinguish between medical product classes I (low risk, II and III (high risk of medical devices according to potential risks for the patient. IF CDSS functions e.g. as modules of a PDMS use vital sign values in the decision algorithms, the PDMS may even be classified as class II medical product, similar to e.g. intravenous pumps. If decision rules of a decision support-system are defined by IT-administrators working for a hospital itself it could even become manufacturer of the medical device.The authors discuss implications and demonstrate difficulties which arise for manufacturers as well as for hospitals or the

  6. Advertising of medical devices: foreign experience and Ukrainian practice.

    Science.gov (United States)

    Pashkov, Vitalii; Harkusha, Andrii; Bytiak, Oleksii

    Chosen European foreign policy vector for Ukraine establishes its obligation to enforce the process of adaptation of the EU law regulations in the internal legal policy. The approximation of Ukrainian law to the European Union (EU) "acquis communautaire" is not only the instrument for deepening our economic cooperation with the European Union, but also the important measure to enhance further development of Ukraine in general. National legislation, which regulate advertising and promotion of medical devices (MD), is not an exception. Some key points on legal regulation of abovementioned sphere is a base of this study. Ukrainian legislation, European Union`s Law Acts, EU's member-states law, WHO Acts and Recommendations, European Medical Technology Industry Association (EUCOMED) Acts. Article is based on dialectical, comparative, analytic, synthetic and comprehensive research methods. In accordance with Ukrainian legislation, there is no special law that concerns advertising on MD in Ukraine, this sphere is regulated by general law that named ≪About advertisement≫, but it doesn't take into account even main characteristics of such a special object as medical devices (MD). Moreover, the law ≪About advertisement≫ contain discrepancies in terms that are used, these contradictions, in our opinion, must be eliminated by appropriate law reforms. The advertising and promotion of MD in EU is regulated by a combination of EU and national legislation of EU Member States, national advertising and promotion of MD are not harmonized with the EU MDD for now, resulting in a fragmented legal landscape that differs from one EU Member State to the other. Practice of adopting different codes and guides that regulate advertising, including advertising of MD, is widespread in EU and EU Member States and thus must be used in Ukraine with appropriate reformation of national law.

  7. The Challenges of Balancing Safety and Security in Implantable Medical Devices.

    Science.gov (United States)

    Katzis, Konstantinos; Jones, Richard W; Despotou, George

    2016-01-01

    Modern Implantable Medical Devices (IMDs), implement capabilities that have contributed significantly to patient outcomes, as well as quality of life. The ever increasing connectivity of IMD's does raise security concerns though there are instances where implemented security measures might impact on patient safety. The paper discusses challenges of addressing both of these attributes in parallel.

  8. Outsourcing versus in-house maintenance of medical devices: a longitudinal, empirical study

    Directory of Open Access Journals (Sweden)

    Antonio Miguel-Cruz

    2014-03-01

    Full Text Available OBJECTIVE: To determine what factors have a significant influence on the performance of medical device maintenance outsourcing, and to determine how the performance of external governance structures differs depending on whether a hospital is private or public. METHODS: This was a longitudinal study of 590 maintenance transactions at 20 hospitals in Bogotá, Colombia, involving 764 medical devices and 72 maintenance service providers. Maintenance performance data (i.e., turn-around time in hours; TAT for the service providers (either in-house or outsourced were primarily collected over a 20-month period, from December 2009-August 2011, by means of a monitoring procedure; then, a hazards model was run. RESULTS: The availability of specific repair parts, in-stock, in the city in which the medical devices were located, had a positive impact on the performance of both internal and external governance structures. Online service also had a positive impact on both, with a stronger positive impact on the performance of internal governance than on that of external governance. For transactions governed by external structures, better performance was seen in private hospitals than in public ones. In public health institutions, internal governance showed better performance than external governance. Both internal and external governance structures showed better performance in private healthcare institutions than in public ones. CONCLUSIONS: In public health institutions, internal governance shows better performance than external governance; this suggests that healthcare managers should reconsider the trend to eliminate in-house maintenance service staff in public healthcare institutions.

  9. Existing reporting guidelines for clinical trials are not completely relevant for implantable medical devices: a systematic review.

    Science.gov (United States)

    Motte, Anne-France; Diallo, Stéphanie; van den Brink, Hélène; Châteauvieux, Constance; Serrano, Carole; Naud, Carole; Steelandt, Julie; Alsac, Jean-Marc; Aubry, Pierre; Cour, Florence; Pellerin, Olivier; Pineau, Judith; Prognon, Patrice; Borget, Isabelle; Bonan, Brigitte; Martelli, Nicolas

    2017-11-01

    The aim of this study was to determine relevant items for reporting clinical trials on implantable medical devices (IMDs) and to identify reporting guidelines which include these items. A panel of experts identified the most relevant items for evaluating IMDs from an initial list based on reference papers. We then conducted a systematic review of articles indexed in MEDLINE. We retrieved reporting guidelines from the EQUATOR network's library for health research reporting. Finally, we screened these reporting guidelines to find those using our set of reporting items. Seven relevant reporting items were selected that related to four topics: randomization, learning curve, surgical setting, and device information. A total of 348 reporting guidelines were identified, among which 26 met our inclusion criteria. However, none of the 26 reporting guidelines presented all seven items together. The most frequently reported item was timing of randomization (65%). On the contrary, device information and learning curve effects were poorly specified. To our knowledge, this study is the first to identify specific items related to IMDs in reporting guidelines for clinical trials. We have shown that no existing reporting guideline is totally suitable for these devices. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. [The SWOT analysis and strategic considerations for the present medical devices' procurement].

    Science.gov (United States)

    Li, Bin; He, Meng-qiao; Cao, Jian-wen

    2006-05-01

    In this paper, the SWOT analysis method is used to find out the internal strength, weakness, exterior opportunities and threats of the present medical devices' procurements in hospitals and some strategic considerations are suggested as "one direction, two expansions, three changes and four countermeasures".

  11. Extraterritorial reach of the FCPA: recommendations for U.S. medical device companies with activities in Europe.

    Science.gov (United States)

    Vollebregt, Erik

    2010-01-01

    Traditionally medical devices companies manage business compliance with anti-corruption and anti-fraud rules in a document-oriented way that does not always yield optimal results for the company. As a result, compliance issues are not optimally managed by the companies. Now that medical devices companies become ever more internationally active, they must also take into account the international dimensions of business compliance. This article intends to provide U.S. medical devices companies with activities in Europe with an insight in business compliance risks in the European Union (EU) and the risks related to U.S. statutes that may be applicable to a U.S. company's activities overseas. The article proposes a process-oriented and IT-supported way of structuring an international business compliance program, resulting in increased effectiveness of the program and increased competitiveness and risk management of the company as well as a high degree of acceptance of the procedures by the company's employees.

  12. Development of bacterially resistant polyurethane for coating medical devices

    International Nuclear Information System (INIS)

    Roohpour, Nima; Moshaverinia, Alireza; Wasikiewicz, Jaroslaw M; Paul, Deepen; Vadgama, Pankaj; Wilks, Mark; Millar, Michael

    2012-01-01

    Polyurethanes have been widely used in medicine for coating and packaging implantable and other medical devices. Polyether-urethanes, in particular, have superior mechanical properties and are biocompatible, but in common with other medical materials they are susceptible to microbial film formation. In this study, polyether-urethane was end-capped with silver lactate and silver sulfadiazine functional groups to produce a bacterially resistant polymer without sacrificing the useful mechanical properties of the polyether-polyurethane. The silver ions were covalently incorporated into the polymer during chain extension of the prepolymer. The functionalized polymers were structurally characterized by light scattering, electron microscopy, NMR, FTIR and Raman spectroscopy. Mechanical properties, hydrophilicity, in vitro stability and antibacterial action of polymers were also investigated. Results indicate that both silver salts were successfully incorporated into the polymer structure without significant effect on mechanical properties, whilst conferring acceptable bacterial resistance.

  13. TU-AB-204-01: Device Approval Process

    International Nuclear Information System (INIS)

    Delfino, J.

    2016-01-01

    The responsibilities of the Food and Drug Administration (FDA) have increased since the inception of the Food and Drugs Act in 1906. Medical devices first came under comprehensive regulation with the passage of the 1938 Food, Drug, and Cosmetic Act. In 1971 FDA also took on the responsibility for consumer protection against unnecessary exposure to radiation-emitting devices for home and occupational use. However it was not until 1976, under the Medical Device Regulation Act, that the FDA was responsible for the safety and effectiveness of medical devices. This session will be presented by the Division of Radiological Health (DRH) and the Division of Imaging, Diagnostics, and Software Reliability (DIDSR) from the Center for Devices and Radiological Health (CDRH) at the FDA. The symposium will discuss on how we protect and promote public health with a focus on medical physics applications organized into four areas: pre-market device review, post-market surveillance, device compliance, current regulatory research efforts and partnerships with other organizations. The pre-market session will summarize the pathways FDA uses to regulate the investigational use and commercialization of diagnostic imaging and radiation therapy medical devices in the US, highlighting resources available to assist investigators and manufacturers. The post-market session will explain the post-market surveillance and compliance activities FDA performs to monitor the safety and effectiveness of devices on the market. The third session will describe research efforts that support the regulatory mission of the Agency. An overview of our regulatory research portfolio to advance our understanding of medical physics and imaging technologies and approaches to their evaluation will be discussed. Lastly, mechanisms that FDA uses to seek public input and promote collaborations with professional, government, and international organizations, such as AAPM, International Electrotechnical Commission (IEC

  14. TU-AB-204-01: Device Approval Process

    Energy Technology Data Exchange (ETDEWEB)

    Delfino, J. [Food & Drug Administration (United States)

    2016-06-15

    The responsibilities of the Food and Drug Administration (FDA) have increased since the inception of the Food and Drugs Act in 1906. Medical devices first came under comprehensive regulation with the passage of the 1938 Food, Drug, and Cosmetic Act. In 1971 FDA also took on the responsibility for consumer protection against unnecessary exposure to radiation-emitting devices for home and occupational use. However it was not until 1976, under the Medical Device Regulation Act, that the FDA was responsible for the safety and effectiveness of medical devices. This session will be presented by the Division of Radiological Health (DRH) and the Division of Imaging, Diagnostics, and Software Reliability (DIDSR) from the Center for Devices and Radiological Health (CDRH) at the FDA. The symposium will discuss on how we protect and promote public health with a focus on medical physics applications organized into four areas: pre-market device review, post-market surveillance, device compliance, current regulatory research efforts and partnerships with other organizations. The pre-market session will summarize the pathways FDA uses to regulate the investigational use and commercialization of diagnostic imaging and radiation therapy medical devices in the US, highlighting resources available to assist investigators and manufacturers. The post-market session will explain the post-market surveillance and compliance activities FDA performs to monitor the safety and effectiveness of devices on the market. The third session will describe research efforts that support the regulatory mission of the Agency. An overview of our regulatory research portfolio to advance our understanding of medical physics and imaging technologies and approaches to their evaluation will be discussed. Lastly, mechanisms that FDA uses to seek public input and promote collaborations with professional, government, and international organizations, such as AAPM, International Electrotechnical Commission (IEC

  15. 78 FR 951 - Accessible Medical Device Labeling in a Standard Content and Format Public Workshop; Request for...

    Science.gov (United States)

    2013-01-07

    ... format so that patients, caregivers, and healthcare providers may access and utilize device labeling as... labeling, and what they would want in a standard version of device labeling. Key findings from the survey... survey with the National Family Caregivers Association (NFCA) on medical device labeling to elicit home...

  16. A medical application integrating remote 3D visualization tools to access picture archiving and communication system on mobile devices.

    Science.gov (United States)

    He, Longjun; Ming, Xing; Liu, Qian

    2014-04-01

    With computing capability and display size growing, the mobile device has been used as a tool to help clinicians view patient information and medical images anywhere and anytime. However, for direct interactive 3D visualization, which plays an important role in radiological diagnosis, the mobile device cannot provide a satisfactory quality of experience for radiologists. This paper developed a medical system that can get medical images from the picture archiving and communication system on the mobile device over the wireless network. In the proposed application, the mobile device got patient information and medical images through a proxy server connecting to the PACS server. Meanwhile, the proxy server integrated a range of 3D visualization techniques, including maximum intensity projection, multi-planar reconstruction and direct volume rendering, to providing shape, brightness, depth and location information generated from the original sectional images for radiologists. Furthermore, an algorithm that changes remote render parameters automatically to adapt to the network status was employed to improve the quality of experience. Finally, performance issues regarding the remote 3D visualization of the medical images over the wireless network of the proposed application were also discussed. The results demonstrated that this proposed medical application could provide a smooth interactive experience in the WLAN and 3G networks.

  17. Medical Device Regulation: A Comparison of the United States and the European Union.

    Science.gov (United States)

    Maak, Travis G; Wylie, James D

    2016-08-01

    Medical device regulation is a controversial topic in both the United States and the European Union. Many physicians and innovators in the United States cite a restrictive US FDA regulatory process as the reason for earlier and more rapid clinical advances in Europe. The FDA approval process mandates that a device be proved efficacious compared with a control or be substantially equivalent to a predicate device, whereas the European Union approval process mandates that the device perform its intended function. Stringent, peer-reviewed safety data have not been reported. However, after recent high-profile device failures, political pressure in both the United States and the European Union has favored more restrictive approval processes. Substantial reforms of the European Union process within the next 5 to 10 years will result in a more stringent approach to device regulation, similar to that of the FDA. Changes in the FDA regulatory process have been suggested but are not imminent.

  18. Touch-free, gesture-based control of medical devices and software based on the leap motion controller.

    Science.gov (United States)

    Mauser, Stanislas; Burgert, Oliver

    2014-01-01

    There are several intra-operative use cases which require the surgeon to interact with medical devices. We used the Leap Motion Controller as input device and implemented two use-cases: 2D-Interaction (e.g. advancing EPR data) and selection of a value (e.g. room illumination brightness). The gesture detection was successful and we mapped its output to several devices and systems.

  19. Ability of Saudi mothers to appropriately and accurately use dosing devices to administer oral liquid medications to their children

    Directory of Open Access Journals (Sweden)

    Almazrou S

    2014-12-01

    Full Text Available Saja Almazrou, Hind Alsahly, Huda Alwattar, Lamya Alturki, Mona Alamri Department of Clinical Pharmacy, College of Pharmacy, King Saud University, Riyadh, Saudi Arabia Background: Most liquid medications are packaged with administration devices, which may be used inappropriately or inaccurately, and sometimes are not used at all. Because of the importance of their proper use for children's health, this study was designed to assess Saudi mothers' experiences with measuring cups, syringes, and droppers for oral liquid medications; to compare accuracy of dosing across these devices; and to determine the effects of mothers' education statuses and pharmacist counseling on dosing accuracy. Methods: This was a cross-sectional study in which mothers were observed as they used a set of commonly available dosing devices which are a dosing cup, syringe, and dropper. Interviews were conducted in the outpatient pharmacy waiting area in several tertiary hospitals and primary clinics in Riyadh, Saudi Arabia between March and April 2013. Saudi women who were mothers of children aged 12 years old or younger and who gave their consent were eligible. Caregivers other than mothers and subjects with vision problems or cognitive/physical disabilities were excluded. We gathered demographic information such as age, number of children, and education status. Subjects were asked if they had had counseling on how to use measuring devices and which device they preferred. Then, the mothers were required to demonstrate how to measure 5 mL of paracetamol (acetaminophen syrup using a cup and a syringe and 1 mL of paracetamol syrup using a dropper. Dosing errors were evaluated visually as overdosing, underdosing, or no error (if the dose was accurate. The data were entered into Microsoft Excel and evaluated using Stata 11.1. Logistic regression was employed to determine relationships. Results: The results revealed that 58% of participants measured an accurate dose of paracetamol

  20. Adverse Events Involving Radiation Oncology Medical Devices: Comprehensive Analysis of US Food and Drug Administration Data, 1991 to 2015

    International Nuclear Information System (INIS)

    Connor, Michael J.; Marshall, Deborah C.; Moiseenko, Vitali; Moore, Kevin; Cervino, Laura; Atwood, Todd; Sanghvi, Parag; Mundt, Arno J.; Pawlicki, Todd; Recht, Abram; Hattangadi-Gluth, Jona A.

    2017-01-01

    Purpose: Radiation oncology relies on rapidly evolving technology and highly complex processes. The US Food and Drug Administration collects reports of adverse events related to medical devices. We sought to characterize all events involving radiation oncology devices (RODs) from the US Food and Drug Administration's postmarket surveillance Manufacturer and User Facility Device Experience (MAUDE) database, comparing these with non–radiation oncology devices. Methods and Materials: MAUDE data on RODs from 1991 to 2015 were sorted into 4 product categories (external beam, brachytherapy, planning systems, and simulation systems) and 5 device problem categories (software, mechanical, electrical, user error, and dose delivery impact). Outcomes included whether the device was evaluated by the manufacturer, adverse event type, remedial action, problem code, device age, and time since 510(k) approval. Descriptive statistics were performed with linear regression of time-series data. Results for RODs were compared with those for other devices by the Pearson χ"2 test for categorical data and 2-sample Kolmogorov-Smirnov test for distributions. Results: There were 4234 ROD and 4,985,698 other device adverse event reports. Adverse event reports increased over time, and events involving RODs peaked in 2011. Most ROD reports involved external beam therapy (50.8%), followed by brachytherapy (24.9%) and treatment planning systems (21.6%). The top problem types were software (30.4%), mechanical (20.9%), and user error (20.4%). RODs differed significantly from other devices in each outcome (P<.001). RODs were more likely to be evaluated by the manufacturer after an event (46.9% vs 33.0%) but less likely to be recalled (10.5% vs 37.9%) (P<.001). Device age and time since 510(k) approval were shorter among RODs (P<.001). Conclusions: Compared with other devices, RODs may experience adverse events sooner after manufacture and market approval. Close postmarket surveillance, improved

  1. Adverse Events Involving Radiation Oncology Medical Devices: Comprehensive Analysis of US Food and Drug Administration Data, 1991 to 2015

    Energy Technology Data Exchange (ETDEWEB)

    Connor, Michael J. [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California (United States); Department of Radiation Oncology, University of California Irvine School of Medicine, Irvine, California (United States); Marshall, Deborah C.; Moiseenko, Vitali; Moore, Kevin; Cervino, Laura; Atwood, Todd; Sanghvi, Parag; Mundt, Arno J.; Pawlicki, Todd [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California (United States); Recht, Abram [Department of Radiation Oncology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts (United States); Hattangadi-Gluth, Jona A., E-mail: jhattangadi@ucsd.edu [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California (United States)

    2017-01-01

    Purpose: Radiation oncology relies on rapidly evolving technology and highly complex processes. The US Food and Drug Administration collects reports of adverse events related to medical devices. We sought to characterize all events involving radiation oncology devices (RODs) from the US Food and Drug Administration's postmarket surveillance Manufacturer and User Facility Device Experience (MAUDE) database, comparing these with non–radiation oncology devices. Methods and Materials: MAUDE data on RODs from 1991 to 2015 were sorted into 4 product categories (external beam, brachytherapy, planning systems, and simulation systems) and 5 device problem categories (software, mechanical, electrical, user error, and dose delivery impact). Outcomes included whether the device was evaluated by the manufacturer, adverse event type, remedial action, problem code, device age, and time since 510(k) approval. Descriptive statistics were performed with linear regression of time-series data. Results for RODs were compared with those for other devices by the Pearson χ{sup 2} test for categorical data and 2-sample Kolmogorov-Smirnov test for distributions. Results: There were 4234 ROD and 4,985,698 other device adverse event reports. Adverse event reports increased over time, and events involving RODs peaked in 2011. Most ROD reports involved external beam therapy (50.8%), followed by brachytherapy (24.9%) and treatment planning systems (21.6%). The top problem types were software (30.4%), mechanical (20.9%), and user error (20.4%). RODs differed significantly from other devices in each outcome (P<.001). RODs were more likely to be evaluated by the manufacturer after an event (46.9% vs 33.0%) but less likely to be recalled (10.5% vs 37.9%) (P<.001). Device age and time since 510(k) approval were shorter among RODs (P<.001). Conclusions: Compared with other devices, RODs may experience adverse events sooner after manufacture and market approval. Close postmarket surveillance

  2. Study on 3D printer production of auxiliary device for upper limb for medical imaging test

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyeong Gyun [Dept. of Radiological Science, Far East University, Eumsung (Korea, Republic of); Yoon, Jae Ho [Jukwang Precision Co., Ltd., Gumi (Korea, Republic of); Choi, Seong Dae [Dept. of Mechanical system engineering, Kumoh Institute of Technology, Gumi (Korea, Republic of)

    2015-12-15

    There is a progressive development in the medical imaging technology, especially of descriptive capability for anatomical structure of human body thanks to advancement of information technology and medical devices. But however maintenance of correct posture is essential for the medical imaging checkup on the shoulder joint requiring rotation of the upper limb due to the complexity of human body. In the cases of MRI examination, long duration and fixed posture are critical, as failure to comply with them leads to minimal possibility of reproducibility only with the efforts of the examiner and will of the patient. Thus, this study aimed to develop an auxiliary device that enables rotation of the upper limb as well as fixing it at quantitative angles for medical imaging examination capable of providing diagnostic values. An auxiliary device has been developed based on the results of precedent studies, by designing a 3D model with the CATIA software, an engineering application, and producing it with the 3D printer. The printer is Objet350 Connex from Stratasys, and acrylonitrile- butadiene-styrene(ABS) is used as the material of the device. Dimensions are 120 X 150 X 190 mm, with the inner diameter of the handle being 125.9 mm. The auxiliary device has 4 components including the body (outside), handle (inside), fixture terminal and the connection part. The body and handle have the gap of 2.1 mm for smooth rotation, while the 360 degree of scales have been etched on the handle so that the angle required for observation may be recorded per patient for traceability and dual examination.

  3. Study on 3D printer production of auxiliary device for upper limb for medical imaging test

    International Nuclear Information System (INIS)

    Kim, Hyeong Gyun; Yoon, Jae Ho; Choi, Seong Dae

    2015-01-01

    There is a progressive development in the medical imaging technology, especially of descriptive capability for anatomical structure of human body thanks to advancement of information technology and medical devices. But however maintenance of correct posture is essential for the medical imaging checkup on the shoulder joint requiring rotation of the upper limb due to the complexity of human body. In the cases of MRI examination, long duration and fixed posture are critical, as failure to comply with them leads to minimal possibility of reproducibility only with the efforts of the examiner and will of the patient. Thus, this study aimed to develop an auxiliary device that enables rotation of the upper limb as well as fixing it at quantitative angles for medical imaging examination capable of providing diagnostic values. An auxiliary device has been developed based on the results of precedent studies, by designing a 3D model with the CATIA software, an engineering application, and producing it with the 3D printer. The printer is Objet350 Connex from Stratasys, and acrylonitrile- butadiene-styrene(ABS) is used as the material of the device. Dimensions are 120 X 150 X 190 mm, with the inner diameter of the handle being 125.9 mm. The auxiliary device has 4 components including the body (outside), handle (inside), fixture terminal and the connection part. The body and handle have the gap of 2.1 mm for smooth rotation, while the 360 degree of scales have been etched on the handle so that the angle required for observation may be recorded per patient for traceability and dual examination

  4. Innovative postmarket device evaluation using a quality registry to monitor thoracic endovascular aortic repair in the treatment of aortic dissection.

    Science.gov (United States)

    Beck, Adam W; Lombardi, Joseph V; Abel, Dorothy B; Morales, J Pablo; Marinac-Dabic, Danica; Wang, Grace; Azizzadeh, Ali; Kern, John; Fillinger, Mark; White, Rodney; Cronenwett, Jack L; Cambria, Richard P

    2017-05-01

    United States Food and Drug Administration (FDA)-mandated postapproval studies have long been a mainstay of the continued evaluation of high-risk medical devices after initial marketing approval; however, these studies often present challenges related to patient/physician recruitment and retention. Retrospective single-center studies also do not fully represent the spectrum of real-world performance nor are they likely to have a sufficiently large enough sample size to detect important signals. In recent years, The FDA Center for Devices and Radiological Health has been promoting the development and use of patient registries to advance infrastructure and methodologies for medical device investigation. The FDA 2012 document, "Strengthening the National System for Medical Device Post-market Surveillance," highlighted registries as a core foundational infrastructure when linked to other complementary data sources, including embedded unique device identification. The Vascular Quality Initiative (VQI) thoracic endovascular aortic repair for type B aortic dissection project is an innovative method of using quality improvement registries to meet the needs of device evaluation after market approval. Here we report the organization and background of this project and highlight the innovation facilitated by collaboration of physicians, the FDA, and device manufacturers. This effort used an existing national network of VQI participants to capture patients undergoing thoracic endovascular aortic repair for acute type B aortic dissection within a registry that aligns with standard practice and existing quality efforts. The VQI captures detailed patient, device, and procedural data for consecutive eligible cases under the auspices of a Patient Safety Organization (PSO). Patients were divided into a 5-year follow-up group (200 acute; 200 chronic dissections) and a 1-year follow-up group (100 acute; 100 chronic). The 5-year cohort required additional imaging details, and the 1-year

  5. Promoting interdisciplinary project-based learning to build the skill sets for research and development of medical devices in academia.

    Science.gov (United States)

    Krishnan, Shankar

    2013-01-01

    The worldwide need for rapid expansion and diversification of medical devices and the corresponding requirements in industry pose arduous challenges for educators to train undergraduate biomedical engineering (BME) students. Preparing BME students for working in the research and development (R&D) in medical device industry is not easily accomplished by adopting traditional pedagogical methods. Even with the inclusion of the design and development elements in capstone projects, medical device industry may be still experience a gap in fulfilling their needs in R&D. This paper proposes a new model based on interdisciplinary project-based learning (IDPBL) to address the requirements of building the necessary skill sets in academia for carrying out R&D in medical device industry. The proposed model incorporates IDPBL modules distributed in a stepwise fashion through the four years of a typical BME program. The proposed model involves buy-in and collaboration from faculty as well as students. The implementation of the proposed design in an undergraduate BME program is still in process. However, a variant of the proposed IDPBL method has been attempted at a limited scale at the postgraduate level and has shown some success. Extrapolating the previous results, the adoption of the IDPBL to BME training seems to suggest promising outcomes. Despite numerous implementation challenges, with continued efforts, the proposed IDPBL will be valuable n academia for skill sets building for medical device R&D.

  6. 75 FR 17143 - Draft Guidance for Industry and Food and Drug Administration Staff; Medical Devices; Neurological...

    Science.gov (United States)

    2010-04-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2009-D-0495] Draft Guidance for Industry and Food and Drug Administration Staff; Medical Devices; Neurological and Physical Medicine Device Guidance Documents; Availability AGENCY: Food and Drug Administration, HHS. ACTION...

  7. 75 FR 44267 - Draft Guidance for Industry and Food and Drug Administration Staff; Medical Devices; Neurological...

    Science.gov (United States)

    2010-07-28

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2009-N-0495] Draft Guidance for Industry and Food and Drug Administration Staff; Medical Devices; Neurological and Physical Medicine Device Guidance Document; Reopening of Comment Period AGENCY: Food and Drug...

  8. Counterfeit drugs and medical devices in developing countries

    Directory of Open Access Journals (Sweden)

    Glass BD

    2014-03-01

    Full Text Available Beverley D GlassSchool of Pharmacy and Molecular Sciences, James Cook University, Townsville, QLD, AustraliaAbstract: The World Health Organization has reported that counterfeit medicines potentially make up more than 50% of the global drug market, with a significant proportion of these fake products being encountered in developing countries. This occurrence is attributed to a lack of effective regulation and a weak enforcement capacity existing in these countries, with an increase in this trade resulting from the growing size and sophistication of drug counterfeiters. In addition, due to both cost and lack of availability of medicines, consumers in developing countries are more likely to seek out these inexpensive options. The World Health Organization is mindful of the impact of counterfeit drugs on consumer confidence in health care systems, health professionals, the supply chain, and genuine suppliers of medicines and medical devices. Antibiotics, antituberculosis drugs, and antimalarial and antiretroviral drugs are frequently targeted, with reports of 60% of the anti-infective drugs in Asia and Africa containing active pharmaceutical ingredients outside their pharmacopoeial limits. This has obvious public health implications of increasing drug resistance and negating all the efforts that have already gone into the provision of medicines to treat these life threatening conditions in the developing world. This review, while focusing on counterfeit medicines and medical devices in developing countries, will present information on their impact and how these issues can be addressed by regulation and control of the supply chain using technology appropriate to the developing world. The complexity of the problem will also be highlighted in terms of the definition of counterfeit and substandard medicines, including gray pharmaceuticals. Although this issue presents as a global public health problem, outcomes in developing countries where counterfeit

  9. Evaluation of E.M.F. exposure from medical electrical equipment

    Energy Technology Data Exchange (ETDEWEB)

    Aniolczyk, H.; Mamrot, P.; Politanski, P. [Nofer Institute of Occupational Medicine, Lodz (Poland)

    2006-07-01

    he medical electric and electronic equipment, including electro surgical devices, short- and microwave diathermy units, and magnetic resonance imaging (MRI) systems, belong to the most hazardous sources of electromagnetic emissions. The electromagnetic emissions can interfere with emissions from other medical equipment located in the same facility (e.g. operation rooms) thus having impact on their work, but more importantly, they can be dangerous to patients, medical personnel operating them and other persons. In the present project, an assessment of E.M.F. intensity was performed for more than 2 000 electro surgical devices (330 khz, 440 khz and 1.76 MHz frequency ranges), 1 200 diathermy units and 45 MRI 0.2 - 1.5 T systems. E.M.F. exposure of medical staff was assessed based on respective national hygienic standards. The actual exposure levels were found to exceed the admissible values in Poland. The recorded E.M.F. intensities were compared with relevant Who and U E recommendations (e.g. I.C.N.I.R.P. guidelines, 1998, Directive 2004/40/E.C.). The findings revealed that for 18% of the devices examined, the E.M.F. was higher than the E.M.F. intensity values recommended by U E. (authors)

  10. Evaluation of E.M.F. exposure from medical electrical equipment

    International Nuclear Information System (INIS)

    Aniolczyk, H.; Mamrot, P.; Politanski, P.

    2006-01-01

    he medical electric and electronic equipment, including electro surgical devices, short- and microwave diathermy units, and magnetic resonance imaging (MRI) systems, belong to the most hazardous sources of electromagnetic emissions. The electromagnetic emissions can interfere with emissions from other medical equipment located in the same facility (e.g. operation rooms) thus having impact on their work, but more importantly, they can be dangerous to patients, medical personnel operating them and other persons. In the present project, an assessment of E.M.F. intensity was performed for more than 2 000 electro surgical devices (330 khz, 440 khz and 1.76 MHz frequency ranges), 1 200 diathermy units and 45 MRI 0.2 - 1.5 T systems. E.M.F. exposure of medical staff was assessed based on respective national hygienic standards. The actual exposure levels were found to exceed the admissible values in Poland. The recorded E.M.F. intensities were compared with relevant Who and U E recommendations (e.g. I.C.N.I.R.P. guidelines, 1998, Directive 2004/40/E.C.). The findings revealed that for 18% of the devices examined, the E.M.F. was higher than the E.M.F. intensity values recommended by U E. (authors)

  11. Sustained prevention of biofilm formation on a novel silicone matrix suitable for medical devices

    DEFF Research Database (Denmark)

    Steffensen, Søren Langer; Merete H., Vestergaard,; Jensen, Minna Grønning

    2015-01-01

    Bacterial colonization and biofilm formation on medical devices constitute major challenges in clinical long-term use of e.g. catheters due to the risk of (re)infection of patients, which would result in additional use of antibiotics risking bacterial resistance development. The aim of the present...... in the range of 1–20 mg/mL. Devices containing 25% (w/w) hydrogel and loaded with ciprofloxacin displayed a strong antibacterial effect against Staphylococcus aureus bacterial colonization and subsequent biofilm formation on the device material was inhibited for 29 days. In conclusion, the hydrogel...

  12. 42 CFR 405.213 - Re-evaluation of a device categorization.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Re-evaluation of a device categorization. 405.213... Decisions That Relate to Health Care Technology § 405.213 Re-evaluation of a device categorization. (a... experimental/investigational (Category A) may request re-evaluation of the categorization decision. (2) A...

  13. Clinical protocol levels are required in laboratory animal surgery when using medical devices: experiences with ureteral replacement surgery in goats.

    Science.gov (United States)

    de Jonge, Paul K J D; Sloff, Marije; Janke, Heinz P; Kortmann, Barbara B M; de Gier, Robert P E; Geutjes, Paul J; Oosterwijk, Egbert; Feitz, Wout F J

    2017-10-01

    It is common to test medical devices in large animal studies that are or could also be used in humans. In this short report we describe the use of a ureteral J-stent for the evaluation of biodegradable tubular constructs for tissue reconstruction, and the regeneration of ureters in Saanen goats. Similarly to a previous study in pigs, the ureteral J-stent was blindly inserted until some resistance was met. During evaluation of the goats after three months, perforation of the renal cortex by the stent was observed in four out of seven animals. These results indicated that blind stent placement was not possible in goats. In four new goats, clinical protocols were followed using X-ray and iodinated contrast fluids to visualize the kidney and stent during stent placement. With this adaptation the stents were successfully placed in the kidneys of these four new goats with minimal additional effort. It is likely that other groups in other fields ran into similar problems that could have been avoided by following clinical protocols. Therefore, we would like to stress the importance of following clinical protocols when using medical devices in animals to prevent unnecessary suffering and to reduce the number of animals needed.

  14. Identification of proteins involved in the adhesionof Candida species to different medical devices.

    Science.gov (United States)

    Núñez-Beltrán, Arianna; López-Romero, Everardo; Cuéllar-Cruz, Mayra

    2017-06-01

    Adhesion is the first step for Candida species to form biofilms on medical devices implanted in the human host. Both the physicochemical nature of the biomaterial and cell wall proteins (CWP) of the pathogen play a determinant role in the process. While it is true that some CWP have been identified in vitro, little is known about the CWP of pathogenic species of Candida involved in adhesion. On this background, we considered it important to investigate the potential role of CWP of C. albicans, C. glabrata, C. krusei and C. parapsilosis in adhesion to different medical devices. Our results indicate that the four species strongly adher to polyvinyl chloride (PVC) devices, followed by polyurethane and finally by silicone. It was interesting to identify fructose-bisphosphate aldolase (Fba1) and enolase 1 (Eno1) as the CWP involved in adhesion of C. albicans, C. glabrata and C. krusei to PVC devices whereas phosphoglycerate kinase (Pgk) and Eno1 allow C. parapsilosis to adher to silicone-made implants. Results presented here suggest that these CWP participate in the initial event of adhesion and are probably followed by other proteins that covalently bind to the biomaterial thus providing conditions for biofilm formation and eventually the onset of infection. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. A study on developpement of guideline on writing technical document for electrical medical devices: Dental x-ray equipment

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Youl; Kim, Jae Ryang; Lee, Jun Ho; Park, Chang Won [Division of Medical Device Research, National Institute of Food and Drug Safety Evaluation, Mnistry of Food and Drug Safety (Korea, Republic of)

    2016-12-15

    Due to recent population aging, the number of check-up for senior citizens has increased steadily. According to this trend, the market size of dental X-ray equipment and the number of approval and review for these devices have simultaneously increased. The technical document of medical device is required for approval and review for medical device, and medical device companies needs to have work comprehension and expertise, as the document needs to include the overall contents such as performances, test criteria, etc.. Yet, since most of domestic manufacturers or importers of medical devices are small businesses, it is difficult for them to recruit professional manpower for approval of medical devices, and submission of inaccurate technical documents has increased. These problems lead to delay of the approval process and to difficulties in quick entering into the market. Especially, the Ministry of Food and Drug safety (MFDS) standards of a dental extra-oral X-ray equipment, a dental intra-oral X-ray equipment, an arm-type computed tomography, and a portable X-ray system have been recently enacted or not. this guideline of dental X-ray equipment adjusting revised standards was developed to help relative companies and reviewers. For this study, first, the methods to write technical document have been reviewed with revised international and domestic regulations and system. Second, the domestic and foreign market status of each item has been surveyed and analyzed. Third, the contents of technical documents already approved by MFDS have been analyzed to select the correct example, test items, criteria, and methods. Finally, the guideline has been developed based on international and domestic regulation, through close review of a consultative body composed of academic, industrial, research institute and government experts.

  16. A study on developpement of guideline on writing technical document for electrical medical devices: Dental x-ray equipment

    International Nuclear Information System (INIS)

    Lee, Seung Youl; Kim, Jae Ryang; Lee, Jun Ho; Park, Chang Won

    2016-01-01

    Due to recent population aging, the number of check-up for senior citizens has increased steadily. According to this trend, the market size of dental X-ray equipment and the number of approval and review for these devices have simultaneously increased. The technical document of medical device is required for approval and review for medical device, and medical device companies needs to have work comprehension and expertise, as the document needs to include the overall contents such as performances, test criteria, etc.. Yet, since most of domestic manufacturers or importers of medical devices are small businesses, it is difficult for them to recruit professional manpower for approval of medical devices, and submission of inaccurate technical documents has increased. These problems lead to delay of the approval process and to difficulties in quick entering into the market. Especially, the Ministry of Food and Drug safety (MFDS) standards of a dental extra-oral X-ray equipment, a dental intra-oral X-ray equipment, an arm-type computed tomography, and a portable X-ray system have been recently enacted or not. this guideline of dental X-ray equipment adjusting revised standards was developed to help relative companies and reviewers. For this study, first, the methods to write technical document have been reviewed with revised international and domestic regulations and system. Second, the domestic and foreign market status of each item has been surveyed and analyzed. Third, the contents of technical documents already approved by MFDS have been analyzed to select the correct example, test items, criteria, and methods. Finally, the guideline has been developed based on international and domestic regulation, through close review of a consultative body composed of academic, industrial, research institute and government experts

  17. 'It's on my iPhone': attitudes to the use of mobile computing devices in medical education, a mixed-methods study.

    Science.gov (United States)

    Wallace, Sean; Clark, Marcia; White, Jonathan

    2012-01-01

    The last decade has seen the introduction of new technology which has transformed many aspects of our culture, commerce, communication and education. This study examined how medical teachers and learners are using mobile computing devices such as the iPhone in medical education and practice, and how they envision them being used in the future. Semistructured interviews were conducted with medical students, residents and faculty to examine participants' attitudes about the current and future use of mobile computing devices in medical education and practice. A thematic approach was used to summarise ideas and concepts expressed, and to develop an online survey. A mixed methods approach was used to integrate qualitative and quantitative findings. Medical students, residents and faculty at a large Canadian medical school in 2011. Interviews were conducted with 18 participants (10 students, 7 residents and 1 faculty member). Only 213 participants responded to the online survey (76 students, 65 residents and 41 faculty members). Over 85% of participants reported using a mobile-computing device. The main uses described for mobile devices related to information management, communication and time management. Advantages identified were portability, flexibility, access to multimedia and the ability to look up information quickly. Challenges identified included: superficial learning, not understanding how to find good learning resources, distraction, inappropriate use and concerns about access and privacy. Both medical students and physicians expressed the view that the use of these devices in medical education and practice will increase in the future. This new technology offers the potential to enhance learning and patient care, but also has potential problems associated with its use. It is important for leadership in medical schools and healthcare organisations to set the agenda in this rapidly developing area to maximise the benefits of this powerful new technology while

  18. Evaluation of STAT medication ordering process in a community hospital

    Directory of Open Access Journals (Sweden)

    Abdelaziz H

    2016-06-01

    Full Text Available Background: In most health care facilities, problems related to delays in STAT medication order processing time are of common concern. Objective: The purpose of this study was to evaluate processing time for STAT orders at Kimball Medical Center. Methods: All STAT orders were reviewed to determine processing time; order processing time was also stratified by physician order entry (physician entered (PE orders vs. non-physician entered (NPE orders. Collected data included medication ordered, indication, time ordered, time verified by pharmacist, time sent from pharmacy, and time charted as given to the patient. Results: A total of 502 STAT orders were reviewed and 389 orders were included for analysis. Overall, median time was 29 minutes, IQR 16–63; p<0.0001. . The time needed to process NPE orders was significantly less than that needed for PE orders (median 27 vs. 34 minutes; p=0.026. In terms of NPE orders, the median total time required to process STAT orders for medications available in the Automated Dispensing Devices (ADM was within 30 minutes, while that required to process orders for medications not available in the ADM was significantly greater than 30 minutes. For PE orders, the median total time required to process orders for medications available in the ADM (i.e., not requiring pharmacy involvement was significantly greater than 30 minutes. [Median time = 34 minutes (p<0.001]. Conclusion: We conclude that STAT order processing time may be improved by increasing the availability of medications in ADM, and pharmacy involvement in the verification process.

  19. A Web-based searchable system to confirm magnetic resonance compatibility of implantable medical devices in Japan: a preliminary study.

    Science.gov (United States)

    Fujiwara, Yasuhiro; Fujioka, Hitoshi; Watanabe, Tomoko; Sekiguchi, Maiko; Murakami, Ryuji

    2017-09-01

    Confirmation of the magnetic resonance (MR) compatibility of implanted medical devices (IMDs) is mandatory before conducting magnetic resonance imaging (MRI) examinations. In Japan, few such confirmation methods are in use, and they are time-consuming. This study aimed to develop a Web-based searchable MR safety information system to confirm IMD compatibility and to evaluate the usefulness of the system. First, MR safety information for intravascular stents and stent grafts sold in Japan was gathered by interviewing 20 manufacturers. These IMDs were categorized based on the descriptions available on medical package inserts as: "MR Safe," "MR Conditional," "MR Unsafe," "Unknown," and "No Medical Package Insert Available". An MR safety information database for implants was created based on previously proposed item lists. Finally, a Web-based searchable system was developed using this database. A questionnaire was given to health-care personnel in Japan to evaluate the usefulness of this system. Seventy-nine datasets were collected using information provided by 12 manufacturers and by investigating the medical packaging of the IMDs. Although the datasets must be updated by collecting data from other manufacturers, this system facilitates the easy and rapid acquisition of MR safety information for IMDs, thereby improving the safety of MRI examinations.

  20. Evaluation of Device-Independent Internet Spatial Location

    Directory of Open Access Journals (Sweden)

    Dan Komosny

    2017-05-01

    Full Text Available Device-independent Internet spatial location is needed for many purposes, such as data personalisation and social behaviour analysis. Internet spatial databases provide such locations based the IP address of a device. The free to use databases are natively included into many UNIX and Linux operating systems. These systems are predominantly used for e-shops, social networks, and cloud data storage. Using a constructed ground truth dataset, we comprehensively evaluate these databases for null responses, returned country/region/city, and distance error. The created ground truth dataset differs from others by covering cities with both low and high populations and maintaining only devices that follow the rule of one IP address per ISP (Internet Service Provider and per city. We define two new performance metrics that show the effect of city population and trustworthiness of the results. We also evaluate the databases against an alternative measurement-based approach. We study the reasons behind the results. The data evaluated comes from Europe. The results may be of use for engineers, developers and researchers that use the knowledge of geographical location for related data processing and analysis, such as marketing.

  1. 31 CFR 560.533 - Brokering sales of agricultural commodities, medicine, and medical devices.

    Science.gov (United States)

    2010-07-01

    ... technical data, software, or information) that are subject to license application requirements of another... IRANIAN TRANSACTIONS REGULATIONS Licenses, Authorizations and Statements of Licensing Policy § 560.533 Brokering sales of agricultural commodities, medicine, and medical devices. (a) General license for...

  2. Establishment of a Quantitative Medical Technology Evaluation System and Indicators within Medical Institutions.

    Science.gov (United States)

    Wu, Suo-Wei; Chen, Tong; Pan, Qi; Wei, Liang-Yu; Wang, Qin; Li, Chao; Song, Jing-Chen; Luo, Ji

    2018-06-05

    The development and application of medical technologies reflect the medical quality and clinical capacity of a hospital. It is also an effective approach in upgrading medical service and core competitiveness among medical institutions. This study aimed to build a quantitative medical technology evaluation system through questionnaire survey within medical institutions to perform an assessment to medical technologies more objectively and accurately, and promote the management of medical quality technologies and ensure the medical safety of various operations among the hospitals. A two-leveled quantitative medical technology evaluation system was built through a two-round questionnaire survey of chosen experts. The Delphi method was applied in identifying the structure of evaluation system and indicators. The judgment of the experts on the indicators was adopted in building the matrix so that the weight coefficient and maximum eigenvalue (λ max), consistency index (CI), and random consistency ratio (CR) could be obtained and collected. The results were verified through consistency tests, and the index weight coefficient of each indicator was conducted and calculated through analytical hierarchy process. Twenty-six experts of different medical fields were involved in the questionnaire survey, 25 of whom successfully responded to the two-round research. Altogether, 4 primary indicators (safety, effectiveness, innovativeness, and benefits), as well as 13 secondary indicators, were included in the evaluation system. The matrix is built to conduct the λ max, CI, and CR of each expert in the survey, and the index weight coefficients of primary indicators were 0.33, 0.28, 0.27, and 0.12, respectively, and the index weight coefficients of secondary indicators were conducted and calculated accordingly. As the two-round questionnaire survey of experts and statistical analysis were performed and credibility of the results was verified through consistency evaluation test, the

  3. Development and evaluation of vision rehabilitation devices.

    Science.gov (United States)

    Luo, Gang; Peli, Eli

    2011-01-01

    We have developed a range of vision rehabilitation devices and techniques for people with impaired vision due to either central vision loss or severely restricted peripheral visual field. We have conducted evaluation studies with patients to test the utilities of these techniques in an effort to document their advantages as well as their limitations. Here we describe our work on a visual field expander based on a head mounted display (HMD) for tunnel vision, a vision enhancement device for central vision loss, and a frequency domain JPEG/MPEG based image enhancement technique. All the evaluation studies included visual search paradigms that are suitable for conducting indoor controllable experiments.

  4. Sodium Hypochlorite Treatment and Nitinol Performance for Medical Devices

    Science.gov (United States)

    Weaver, J. D.; Gutierrez, E. J.; Nagaraja, S.; Stafford, P. R.; Sivan, S.; Di Prima, M.

    2017-09-01

    Processing of nitinol medical devices has evolved over the years as manufacturers have identified methods of reducing surface defects such as inclusions. One recent method proposes to soak nitinol medical devices in a 6% sodium hypochlorite (NaClO) solution as a means of identifying surface inclusions. Devices with surface inclusions could in theory then be removed from production because inclusions would interact with NaClO to form a visible black material on the nitinol surface. To understand the effects of an NaClO soak on performance, we compared as-received and NaClO-soaked nitinol wires with two different surface finishes (black oxide and electropolished). Pitting corrosion susceptibility was equivalent between the as-received and NaClO-soaked groups for both surface finishes. Nickel ion release increased in the NaClO-soaked group for black oxide nitinol, but was equivalent for electropolished nitinol. Fatigue testing revealed a lower fatigue life for NaClO-soaked black oxide nitinol at all alternating strains. With the exception of 0.83% alternating strain, NaClO-soaked and as-received electropolished nitinol had similar average fatigue life, but the NaClO-soaked group showed higher variability. NaClO-soaked electropolished nitinol had specimens with the lowest number of cycles to fracture for all alternating strains tested with the exception of the highest alternating strain 1.2%. The NaClO treatment identified only one specimen with surface inclusions and caused readily identifiable surface damage to the black oxide nitinol. Damage from the NaClO soak to electropolished nitinol surface also appears to have occurred and is likely the cause of the increased variability of the fatigue results. Overall, the NaClO soak appears to not lead to an improvement in nitinol performance and seems to be damaging to the nitinol surface in ways that may not be detectable with a simple visual inspection for black material on the nitinol surface.

  5. Cybersecurity vulnerabilities in medical devices: a complex environment and multifaceted problem

    Directory of Open Access Journals (Sweden)

    Williams PAH

    2015-07-01

    Full Text Available Patricia AH Williams, Andrew J Woodward eHealth Research Group and Security Research Institute, Edith Cowan University, Perth, WA, Australia Abstract: The increased connectivity to existing computer networks has exposed medical devices to cybersecurity vulnerabilities from which they were previously shielded. For the prevention of cybersecurity incidents, it is important to recognize the complexity of the operational environment as well as to catalog the technical vulnerabilities. Cybersecurity protection is not just a technical issue; it is a richer and more intricate problem to solve. A review of the factors that contribute to such a potentially insecure environment, together with the identification of the vulnerabilities, is important for understanding why these vulnerabilities persist and what the solution space should look like. This multifaceted problem must be viewed from a systemic perspective if adequate protection is to be put in place and patient safety concerns addressed. This requires technical controls, governance, resilience measures, consolidated reporting, context expertise, regulation, and standards. It is evident that a coordinated, proactive approach to address this complex challenge is essential. In the interim, patient safety is under threat. Keywords: cybersecurity, security, safety, wireless, risk, medical devices

  6. Modification of the surfaces of medical devices to prevent microbial adhesion and biofilm formation.

    Science.gov (United States)

    Desrousseaux, C; Sautou, V; Descamps, S; Traoré, O

    2013-10-01

    The development of devices with surfaces that have an effect against microbial adhesion or viability is a promising approach to the prevention of device-related infections. To review the strategies used to design devices with surfaces able to limit microbial adhesion and/or growth. A PubMed search of the published literature. One strategy is to design medical devices with a biocidal agent. Biocides can be incorporated into the materials or coated or covalently bonded, resulting either in release of the biocide or in contact killing without release of the biocide. The use of biocides in medical devices is debated because of the risk of bacterial resistance and potential toxicity. Another strategy is to modify the chemical or physical surface properties of the materials to prevent microbial adhesion, a complex phenomenon that also depends directly on microbial biological structure and the environment. Anti-adhesive chemical surface modifications mostly target the hydrophobicity features of the materials. Topographical modifications are focused on roughness and nanostructures, whose size and spatial organization are controlled. The most effective physical parameters to reduce bacterial adhesion remain to be determined and could depend on shape and other bacterial characteristics. A prevention strategy based on reducing microbial attachment rather than on releasing a biocide is promising. Evidence of the clinical efficacy of these surface-modified devices is lacking. Additional studies are needed to determine which physical features have the greatest potential for reducing adhesion and to assess the usefulness of antimicrobial coatings other than antibiotics. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  7. 76 FR 48169 - Advancing Regulatory Science for Highly Multiplexed Microbiology/Medical Countermeasure Devices...

    Science.gov (United States)

    2011-08-08

    ... microbiology/MCM device, their clinical application and public health/clinical needs and quality criteria for... topics: 1. Clinical Application of Highly Multiplexed Microbiology Devices: Their clinical application... to evaluate the analytical and clinical performance of highly multiplexed microbiology devices...

  8. Security and privacy issues in implantable medical devices: A comprehensive survey.

    Science.gov (United States)

    Camara, Carmen; Peris-Lopez, Pedro; Tapiador, Juan E

    2015-06-01

    Bioengineering is a field in expansion. New technologies are appearing to provide a more efficient treatment of diseases or human deficiencies. Implantable Medical Devices (IMDs) constitute one example, these being devices with more computing, decision making and communication capabilities. Several research works in the computer security field have identified serious security and privacy risks in IMDs that could compromise the implant and even the health of the patient who carries it. This article surveys the main security goals for the next generation of IMDs and analyzes the most relevant protection mechanisms proposed so far. On the one hand, the security proposals must have into consideration the inherent constraints of these small and implanted devices: energy, storage and computing power. On the other hand, proposed solutions must achieve an adequate balance between the safety of the patient and the security level offered, with the battery lifetime being another critical parameter in the design phase. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. 76 FR 7222 - Medical Device Innovation Initiative; Public Meeting; Request for Comments

    Science.gov (United States)

    2011-02-09

    ... public meeting will be provided on a space-available basis beginning at 7 a.m. Non-U.S. citizens are... The United States is the global leader in medical device innovation and CDRH is committed to assuring... public health. CDRH is responsible for advancing public health and facilitating innovation to help bring...

  10. Current challenges for clinical trials of cardiovascular medical devices.

    Science.gov (United States)

    Zannad, Faiez; Stough, Wendy Gattis; Piña, Ileana L; Mehran, Roxana; Abraham, William T; Anker, Stefan D; De Ferrari, Gaetano M; Farb, Andrew; Geller, Nancy L; Kieval, Robert S; Linde, Cecilia; Redberg, Rita F; Stein, Kenneth; Vincent, Alphons; Woehrle, Holger; Pocock, Stuart J

    2014-07-15

    Several features of cardiovascular devices raise considerations for clinical trial conduct. Prospective, randomized, controlled trials remain the highest quality evidence for safety and effectiveness assessments, but, for instance, blinding may be challenging. In order to avoid bias and not confound data interpretation, the use of objective endpoints and blinding patients, study staff, core labs, and clinical endpoint committees to treatment assignment are helpful approaches. Anticipation of potential bias should be considered and planned for prospectively in a cardiovascular device trial. Prospective, single-arm studies (often referred to as registry studies) can provide additional data in some cases. They are subject to selection bias even when carefully designed; thus, they are generally not acceptable as the sole basis for pre-market approval of high risk cardiovascular devices. However, they complement the evidence base and fill the gaps unanswered by randomized trials. Registry studies present device safety and effectiveness in day-to-day clinical practice settings and detect rare adverse events in the post-market period. No single research design will be appropriate for every cardiovascular device or target patient population. The type of trial, appropriate control group, and optimal length of follow-up will depend on the specific device, its potential clinical benefits, the target patient population and the existence (or lack) of effective therapies, and its anticipated risks. Continued efforts on the part of investigators, the device industry, and government regulators are needed to reach the optimal approach for evaluating the safety and performance of innovative devices for the treatment of cardiovascular disease. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  11. Signal Quality Evaluation of Emerging EEG Devices

    Directory of Open Access Journals (Sweden)

    Thea Radüntz

    2018-02-01

    Full Text Available Electroencephalogram (EEG registration as a direct measure of brain activity has unique potentials. It is one of the most reliable and predicative indicators when studying human cognition, evaluating a subject's health condition, or monitoring their mental state. Unfortunately, standard signal acquisition procedures limit the usability of EEG devices and narrow their application outside the lab. Emerging sensor technology allows gel-free EEG registration and wireless signal transmission. Thus, it enables quick and easy application of EEG devices by users themselves. Although a main requirement for the interpretation of an EEG is good signal quality, there is a lack of research on this topic in relation to new devices. In our work, we compared the signal quality of six very different EEG devices. On six consecutive days, 24 subjects wore each device for 60 min and completed tasks and games on the computer. The registered signals were evaluated in the time and frequency domains. In the time domain, we examined the percentage of artifact-contaminated EEG segments and the signal-to-noise ratios. In the frequency domain, we focused on the band power variation in relation to task demands. The results indicated that the signal quality of a mobile, gel-based EEG system could not be surpassed by that of a gel-free system. However, some of the mobile dry-electrode devices offered signals that were almost comparable and were very promising. This study provided a differentiated view of the signal quality of emerging mobile and gel-free EEG recording technology and allowed an assessment of the functionality of the new devices. Hence, it provided a crucial prerequisite for their general application, while simultaneously supporting their further development.

  12. Continuous Context-Aware Device Comfort Evaluation Method

    DEFF Research Database (Denmark)

    Guo, Jingjing; Jensen, Christian D.; Ma, Jianfeng

    2015-01-01

    Mobile devices have become more powerful and are increasingly integrated in the everyday life of people; from playing games, taking pictures and interacting with social media to replacing credit cards in payment solutions. The security of a mobile device is therefore increasingly linked to its...... context, such as its location, surroundings (e.g. objects and people in the immediate environment) and so on, because some actions may only be appropriate in some situations; this is not captured by traditional security models. In this paper, we examine the notion of Device Comfort and propose a way...... to calculate the sensitivity of a specific action to the context. We present two different methods for a mobile device to dynamically evaluate its security status when an action is requested, either by the user or by another device. The first method uses the predefined ideal context as a standard to assess...

  13. CSIR research, development and innovation initiatives for the medical device and diagnostic industry

    CSIR Research Space (South Africa)

    Vilakazi, Busisiwe

    2017-10-01

    Full Text Available This presentation is focused on development and innovation initiatives in the medical device and diagnostic industry. It is presented by Dr Busisiwe Vilakasi at The 6th CSIR Conference: Ideas that work for industrial development, 5-6 October 2017...

  14. High-Confidence Medical Devices: Cyber-Physical Systems for 21st Century Health Care

    Data.gov (United States)

    Networking and Information Technology Research and Development, Executive Office of the President — The U.S. market for medical devices is the largest in the world. At an estimated $83 billion in 2006, this market represents nearly half the global total and is...

  15. Radiation exams in occupational medical evaluations

    International Nuclear Information System (INIS)

    Gelsleichter, A.M.; Hunh, A.; Nandi, D.M.

    2017-01-01

    Introduction: In occupational medicine, medical care must be geared toward the prevention of worker health. However, occupational medical exams often seek only through rigorous screening, reduce absenteeism, and thus increase productivity. To meet this goal, many institutions include radiological examinations indiscriminately in their medical and expert evaluations, contrary to the principle of justification. Objective: To provide a reflection about the presence of radiological exams in occupational medical evaluations. Methodology: Literary review including legislation related to the research topic. Results: Portaria 453/98 ANVISA prohibits the performance of radiological examinations for employment or expert purposes, except in cases where the exam may bring a benefit to the health of the individual examined or to society. However, in some situations the Norma Regulamentadora number 7 of the Ministry of Labor and Employment provides for radiological exams as a parameter for monitoring occupational exposure. Article 168 of the Consolidation of Labor Laws also prescribes that additional examinations may be required, at the medical discretion, to determine the physical and mental fitness of the employee for the job. Conclusion: Although there are legal provisions that prohibit and others that allow radiological exams in medical occupational evaluations, companies and institutions should take into account that any radiological exam has a risk involved and should not request them in a compulsory and indiscriminate manner. Radiological exams are only permissible to elucidate the diagnostic hypothesis produced by clinical evaluation, in order to provide a real benefit for the individual

  16. Simulation of leakage current measurement on medical devices using helmholtz coil configuration with different current flow

    Science.gov (United States)

    Sutanto, E.; Chandra, F.; Dinata, R.

    2017-05-01

    Leakage current measurement which can follow IEC standard for medical device is one of many challenges to be answered. The IEC 60601-1 has defined that the limit for a leakage current for Medical Device can be as low as 10 µA and as high as 500 µA, depending on which type of contact (applied part) connected to the patient. Most people are using ELCB (Earth-leakage circuit breaker) for safety purpose as this is the most common and available safety device in market. One type of ELCB devices is RCD (Residual Current Device) and this RCD type can measure the leakage current directly. This work will show the possibility on how Helmholtz Coil Configuration can be made to be like the RCD. The possibility is explored by comparing the magnetic field formula from each device, then it proceeds with a simulation using software EJS (Easy Java Simulation). The simulation will make sure the concept of magnetic field current cancellation follows the RCD concept. Finally, the possibility of increasing the measurement’s sensitivity is also analyzed. The sensitivity is needed to see the possibility on reaching the minimum leakage current limit defined by IEC, 0.01mA.

  17. Simulation of leakage current measurement on medical devices using helmholtz coil configuration with different current flow

    International Nuclear Information System (INIS)

    Sutanto, E; Chandra, F; Dinata, R

    2017-01-01

    Leakage current measurement which can follow IEC standard for medical device is one of many challenges to be answered. The IEC 60601-1 has defined that the limit for a leakage current for Medical Device can be as low as 10 µA and as high as 500 µA, depending on which type of contact (applied part) connected to the patient. Most people are using ELCB (Earth-leakage circuit breaker) for safety purpose as this is the most common and available safety device in market. One type of ELCB devices is RCD (Residual Current Device) and this RCD type can measure the leakage current directly. This work will show the possibility on how Helmholtz Coil Configuration can be made to be like the RCD. The possibility is explored by comparing the magnetic field formula from each device, then it proceeds with a simulation using software EJS (Easy Java Simulation). The simulation will make sure the concept of magnetic field current cancellation follows the RCD concept. Finally, the possibility of increasing the measurement’s sensitivity is also analyzed. The sensitivity is needed to see the possibility on reaching the minimum leakage current limit defined by IEC, 0.01mA. (paper)

  18. FDA (Food and Drug Administration) compliance program guidance manual and updates (FY 86). Section 4. Medical and radiological devices. Irregular report

    International Nuclear Information System (INIS)

    1986-01-01

    The FDA Compliance Program Guidance Manual provides a system for issuing and filing program plans and instructions directed to Food and Drug Administration Field operations for project implementation. Section IV provides those chapters of the Compliance Program Guidance Manual which pertain to the areas of medical and radiological devices. Some of the areas of coverage include laser and sunlamp standards inspections, compliance testing of various radiation-emitting products such as television receivers and microwave ovens, emergency response planning and policy, premarket approval and device manufacturers inspections, device problem reporting, sterilization of devices, and consumer education programs on medical and radiological devices

  19. 76 FR 45826 - Medical Device User Fee Rates for Fiscal Year 2012

    Science.gov (United States)

    2011-08-01

    ... paper check: All paper checks must be in U.S. currency from a U.S. bank and made payable to the Food and... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0542] Medical Device User Fee Rates for Fiscal Year 2012 AGENCY: Food and Drug Administration, HHS. ACTION...

  20. Exer-Genie(Registered Trademark) Exercise Device Hardware Evaluation

    Science.gov (United States)

    Schaffner, Grant; Sharp,Carwyn; Stroud, Leah

    2008-01-01

    An engineering evaluation was performed on the ExerGenie(r) exercise device to quantify its capabilities and limitations to address questions from the Constellation Program. Three subjects performed rowing and circuit training sessions to assess the suitability of the device for aerobic exercise. Three subjects performed a resistive exercise session to assess the suitability of the device for resistive exercise. Since 1 subject performed both aerobic and resistive exercise sessions, a total of 5 subjects participated.

  1. Risk assessment and comparative effectiveness of left ventricular assist device and medical management in ambulatory heart failure patients: design and rationale of the ROADMAP clinical trial.

    Science.gov (United States)

    Rogers, Joseph G; Boyle, Andrew J; O'Connell, John B; Horstmanshof, Douglas A; Haas, Donald C; Slaughter, Mark S; Park, Soon J; Farrar, David J; Starling, Randall C

    2015-02-01

    Mechanical circulatory support is now a proven therapy for the treatment of patients with advanced heart failure and cardiogenic shock. The role for this therapy in patients with less severe heart failure is unknown. The objective of this study is to examine the impact of mechanically assisted circulation using the HeartMate II left ventricular assist device in patients who meet current US Food and Drug Administration-defined criteria for treatment but are not yet receiving intravenous inotropic therapy. This is a prospective, nonrandomized clinical trial of 200 patients treated with either optimal medical management or a mechanical circulatory support device. This trial will be the first prospective clinical evaluation comparing outcomes of patients with advanced ambulatory heart failure treated with either ongoing medical therapy or a left ventricular assist device. It is anticipated to provide novel insights regarding relative outcomes with each treatment and an understanding of patient and provider acceptance of the ventricular assist device therapy. This trial will also provide information regarding the risk of events in "stable" patients with advanced heart failure and guidance for the optimal timing of left ventricular assist device therapy. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Real-time signal processing of accelerometer data for wearable medical patient monitoring devices.

    Science.gov (United States)

    Van Wieringen, Matt; Eklund, J

    2008-01-01

    Elderly and other people who live at home but required some physical assistance to do so are often more susceptible injury causing falls in and around their place of residence. In the event that a fall does occur, as a direct result of a previous medical condition or the fall itself, these people are typically less likely to be able to seek timely medical help without assistance. The goal of this research is to develop a wearable sensor device that uses an accelerometer for monitoring the movement of the person to detect falls after they have occurred in order to enable timely medical assistance. The data coming from the accelerometer is processed in real-time in the device and sent to a remote monitoring station where operators can attempt to make contact with the person and/or notify medical personnel of the situation. The ADXL330 accelerometer is contained within a Nintendo WiiMote controller, which forms the basis of the wearable medical sensor. The accelerometer data can then be sent via Bluetooth connection and processed by a local gateway processor. If a fall is detected, the gateway will then contact a remote monitoring station, on a cellular network, for example, via satellite, and/or through a hardwired phone or Internet connection. To detect the occurrence of ta fall, the accelerometer data is passed through a matched filter and the data is compared to benchmark analysis data that will define the conditions that represents the occurrence of a fall.

  3. 75 FR 15439 - Food and Drug Administration/Xavier University Global Medical Device Conference

    Science.gov (United States)

    2010-03-29

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0001] Food and Drug Administration/Xavier University Global Medical Device Conference AGENCY: Food and Drug Administration, HHS. ACTION: Notice of public conference. SUMMARY: The Food and Drug Administration (FDA...

  4. 78 FR 15957 - Food and Drug Administration/Xavier University Global Medical Device Conference

    Science.gov (United States)

    2013-03-13

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-0001] Food and Drug Administration/Xavier University Global Medical Device Conference AGENCY: Food and Drug Administration, HHS. ACTION: Notice of public conference. SUMMARY: The Food and Drug Administration (FDA...

  5. 77 FR 10537 - Food and Drug Administration/Xavier University Global Medical Device Conference

    Science.gov (United States)

    2012-02-22

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-N-0001] Food and Drug Administration/Xavier University Global Medical Device Conference AGENCY: Food and Drug Administration, HHS. ACTION: Notice of public conference. SUMMARY: The Food and Drug Administration (FDA...

  6. Improving evaluation at two medical schools.

    Science.gov (United States)

    Schiekirka-Schwake, Sarah; Dreiling, Katharina; Pyka, Katharina; Anders, Sven; von Steinbüchel, Nicole; Raupach, Tobias

    2017-08-03

    Student evaluations of teaching can provide useful feedback for teachers and programme coordinators alike. We have designed a novel evaluation tool assessing teacher performance and student learning outcome. This tool was implemented at two German medical schools. In this article, we report student and teacher perceptions of the novel tool, and the implementation process. Focus group discussions as well as one-to-one interviews involving 22 teachers and 31 undergraduate medical students were conducted. Following adjustments to the feedback reports (e.g. the colour coding of results) at one medical school, 42 teachers were asked about their perceptions of the revised report and the personal benefit of the evaluation tool. Teachers appreciated the individual feedback provided by the evaluation tool and stated that they wanted to improve their teaching, based on the results; however, they missed most of the preparative communication. Students were unsure about the additional benefit of the instrument compared with traditional evaluation tools. A majority was unwilling to complete evaluation forms in their spare time, and some felt that the new questionnaire was too long and that the evaluations occurred too often. They were particularly interested in feedback on how their comments have helped to further improve teaching. Student evaluations of teaching can provide useful feedback CONCLUSION: Despite evidence of the utility of the tool for individual teachers, implementation of changes to the process of evaluation appears to have been suboptimal, mainly owing to a perceived lack of communication. In order to motivate students to provide evaluation data, feedback loops including aims and consequences should be established. © 2017 John Wiley & Sons Ltd and The Association for the Study of Medical Education.

  7. Experimental evaluation of cooling efficiency of the high performance cooling device

    Science.gov (United States)

    Nemec, Patrik; Malcho, Milan

    2016-06-01

    This work deal with experimental evaluation of cooling efficiency of cooling device capable transfer high heat fluxes from electric elements to the surrounding. The work contain description of cooling device, working principle of cooling device, construction of cooling device. Experimental part describe the measuring method of device cooling efficiency evaluation. The work results are presented in graphic visualization of temperature dependence of the contact area surface between cooling device evaporator and electronic components on the loaded heat of electronic components in range from 250 to 740 W and temperature dependence of the loop thermosiphon condenser surface on the loaded heat of electronic components in range from 250 to 740 W.

  8. Experimental evaluation of cooling efficiency of the high performance cooling device

    Energy Technology Data Exchange (ETDEWEB)

    Nemec, Patrik, E-mail: patrik.nemec@fstroj.uniza.sk; Malcho, Milan, E-mail: milan.malcho@fstroj.uniza.sk [University of Žilina, Faculty of Mechanical Engineering, Department of Power Engineering, Univerzitna 1, 010 26 Žilina (Slovakia)

    2016-06-30

    This work deal with experimental evaluation of cooling efficiency of cooling device capable transfer high heat fluxes from electric elements to the surrounding. The work contain description of cooling device, working principle of cooling device, construction of cooling device. Experimental part describe the measuring method of device cooling efficiency evaluation. The work results are presented in graphic visualization of temperature dependence of the contact area surface between cooling device evaporator and electronic components on the loaded heat of electronic components in range from 250 to 740 W and temperature dependence of the loop thermosiphon condenser surface on the loaded heat of electronic components in range from 250 to 740 W.

  9. Do single-use medical devices containing biopolymers reduce the environmental impacts of surgical procedures compared with their plastic equivalents?

    Science.gov (United States)

    Unger, Scott R; Hottle, Troy A; Hobbs, Shakira R; Thiel, Cassandra L; Campion, Nicole; Bilec, Melissa M; Landis, Amy E

    2017-01-01

    Background While petroleum-based plastics are extensively used in health care, recent developments in biopolymer manufacturing have created new opportunities for increased integration of biopolymers into medical products, devices and services. This study compared the environmental impacts of single-use disposable devices with increased biopolymer content versus typically manufactured devices in hysterectomy. Methods A comparative life cycle assessment of single-use disposable medical products containing plastic(s) versus the same single-use medical devices with biopolymers substituted for plastic(s) at Magee-Women's Hospital (Magee) in Pittsburgh, PA and the products used in four types of hysterectomies that contained plastics potentially suitable for biopolymer substitution. Magee is a 360-bed teaching hospital, which performs approximately 1400 hysterectomies annually. Results There are life cycle environmental impact tradeoffs when substituting biopolymers for petroplastics in procedures such as hysterectomies. The substitution of biopolymers for petroleum-based plastics increased smog-related impacts by approximately 900% for laparoscopic and robotic hysterectomies, and increased ozone depletion-related impacts by approximately 125% for laparoscopic and robotic hysterectomies. Conversely, biopolymers reduced life cycle human health impacts, acidification and cumulative energy demand for the four hysterectomy procedures. The integration of biopolymers into medical products is correlated with reductions in carcinogenic impacts, non-carcinogenic impacts and respiratory effects. However, the significant agricultural inputs associated with manufacturing biopolymers exacerbate environmental impacts of products and devices made using biopolymers. Conclusions The integration of biopolymers into medical products is correlated with reductions in carcinogenic impacts, non-carcinogenic impacts and respiratory effects; however, the significant agricultural inputs associated

  10. Evaluation of device-independent internet spatial location

    OpenAIRE

    Komosný, Dan; Pang, Paul; Mehic, Miralem; Vozňák, Miroslav

    2017-01-01

    Device-independent Internet spatial location is needed for many purposes, such as data personalisation and social behaviour analysis. Internet spatial databases provide such locations based the IP address of a device. The free to use databases are natively included into many UNIX and Linux operating systems. These systems are predominantly used for e-shops, social networks, and cloud data storage. Using a constructed ground truth dataset, we comprehensively evaluate these databases for null r...

  11. A review of the latest guidelines for NIBP device validation.

    Science.gov (United States)

    Alpert, Bruce S; Quinn, David E; Friedman, Bruce A

    2013-12-01

    The current ISO Standard is accepted as the National Standard in almost every industrialized nation. An overview of the most recently adopted standards is provided. Standards writing groups including the Advancement of Medical Instrumentation Sphygmomanometer Committee and ISO JWG7 are working to expand standardized evaluation methods to include the evaluation of devices intended for use in environments where motion artifact is common. An Association for the Advancement of Medical Instrumentation task group on noninvasive blood pressure measurement in the presence of motion artifact has published a technical information report containing research and standardized methods for the evaluation of blood pressure device performance in the presence of motion artifact.

  12. [Introduction of Quality Management System Audit in Medical Device Single Audit Program].

    Science.gov (United States)

    Wen, Jing; Xiao, Jiangyi; Wang, Aijun

    2018-01-30

    The audit of the quality management system in the medical device single audit program covers the requirements of several national regulatory authorities, which has a very important reference value. This paper briefly described the procedures and contents of this audit. Some enlightenment on supervision and inspection are discussed in China, for reference by the regulatory authorities and auditing organizations.

  13. Improving Patient Safety with X-Ray and Anesthesia Machine Ventilator Synchronization: A Medical Device Interoperability Case Study

    Science.gov (United States)

    Arney, David; Goldman, Julian M.; Whitehead, Susan F.; Lee, Insup

    When a x-ray image is needed during surgery, clinicians may stop the anesthesia machine ventilator while the exposure is made. If the ventilator is not restarted promptly, the patient may experience severe complications. This paper explores the interconnection of a ventilator and simulated x-ray into a prototype plug-and-play medical device system. This work assists ongoing interoperability framework development standards efforts to develop functional and non-functional requirements and illustrates the potential patient safety benefits of interoperable medical device systems by implementing a solution to a clinical use case requiring interoperability.

  14. 78 FR 21612 - Medical Device Classification Product Codes; Guidance for Industry and Food and Drug...

    Science.gov (United States)

    2013-04-11

    ... driving force for CDRH's internal organizational structure as well. These Panels were established with the... guidance represents the Agency's current thinking on medical device classification product codes. It does...

  15. Registry Assessment of Peripheral Interventional Devices (RAPID) - Registry Assessment of Peripheral Interventional Devices Core Data Elements.

    Science.gov (United States)

    Jones, W Schuyler; Krucoff, Mitchell W; Morales, Pablo; Wilgus, Rebecca W; Heath, Anne H; Williams, Mary F; Tcheng, James E; Marinac-Dabic, J Danica; Malone, Misti L; Reed, Terrie L; Fukaya, Rie; Lookstein, Robert; Handa, Nobuhiro; Aronow, Herbert D; Bertges, Daniel J; Jaff, Michael R; Tsai, Thomas T; Smale, Joshua A; Zaugg, Margo J; Thatcher, Robert J; Cronenwett, Jack L; Nc, Durham; Md, Silver Spring; Japan, Tokyo; Ny, New York; Ri, Providence; Vt, Burlington; Mass, Newton; Colo, Denver; Ariz, Tempe; Calif, Santa Clara; Minn, Minneapolis; Nh, Lebanon

    2018-01-25

    The current state of evaluating patients with peripheral artery disease and more specifically of evaluating medical devices used for peripheral vascular intervention (PVI) remains challenging because of the heterogeneity of the disease process, the multiple physician specialties that perform PVI, the multitude of devices available to treat peripheral artery disease, and the lack of consensus about the best treatment approaches. Because PVI core data elements are not standardized across clinical care, clinical trials, and registries, aggregation of data across different data sources and physician specialties is currently not feasible.Methods and Results:Under the auspices of the U.S. Food and Drug Administration's Medical Device Epidemiology Network initiative-and its PASSION (Predictable and Sustainable Implementation of the National Registries) program, in conjunction with other efforts to align clinical data standards-the Registry Assessment of Peripheral Interventional Devices (RAPID) workgroup was convened. RAPID is a collaborative, multidisciplinary effort to develop a consensus lexicon and to promote interoperability across clinical care, clinical trials, and national and international registries of PVI. The current manuscript presents the initial work from RAPID to standardize clinical data elements and definitions, to establish a framework within electronic health records and health information technology procedural reporting systems, and to implement an informatics-based approach to promote the conduct of pragmatic clinical trials and registry efforts in PVI. Ultimately, we hope this work will facilitate and improve device evaluation and surveillance for patients, clinicians, health outcomes researchers, industry, policymakers, and regulators.

  16. Implementation of a low-cost mobile devices to support medical diagnosis.

    Science.gov (United States)

    García Sánchez, Carlos; Botella Juan, Guillermo; Ayuso Márquez, Fermín; González Rodríguez, Diego; Prieto-Matías, Manuel; Tirado Fernández, Francisco

    2013-01-01

    Medical imaging has become an absolutely essential diagnostic tool for clinical practices; at present, pathologies can be detected with an earliness never before known. Its use has not only been relegated to the field of radiology but also, increasingly, to computer-based imaging processes prior to surgery. Motion analysis, in particular, plays an important role in analyzing activities or behaviors of live objects in medicine. This short paper presents several low-cost hardware implementation approaches for the new generation of tablets and/or smartphones for estimating motion compensation and segmentation in medical images. These systems have been optimized for breast cancer diagnosis using magnetic resonance imaging technology with several advantages over traditional X-ray mammography, for example, obtaining patient information during a short period. This paper also addresses the challenge of offering a medical tool that runs on widespread portable devices, both on tablets and/or smartphones to aid in patient diagnostics.

  17. Implementation of a Low-Cost Mobile Devices to Support Medical Diagnosis

    Directory of Open Access Journals (Sweden)

    Carlos García Sánchez

    2013-01-01

    Full Text Available Medical imaging has become an absolutely essential diagnostic tool for clinical practices; at present, pathologies can be detected with an earliness never before known. Its use has not only been relegated to the field of radiology but also, increasingly, to computer-based imaging processes prior to surgery. Motion analysis, in particular, plays an important role in analyzing activities or behaviors of live objects in medicine. This short paper presents several low-cost hardware implementation approaches for the new generation of tablets and/or smartphones for estimating motion compensation and segmentation in medical images. These systems have been optimized for breast cancer diagnosis using magnetic resonance imaging technology with several advantages over traditional X-ray mammography, for example, obtaining patient information during a short period. This paper also addresses the challenge of offering a medical tool that runs on widespread portable devices, both on tablets and/or smartphones to aid in patient diagnostics.

  18. Security and privacy for implantable medical devices

    CERN Document Server

    Carrara, Sandro

    2014-01-01

     This book presents a systematic approach to analyzing the challenging engineering problems posed by the need for security and privacy in implantable medical devices (IMD).  It describes in detail new issues termed as lightweight security, due to the associated constraints on metrics such as available power, energy, computing ability, area, execution time, and memory requirements. Coverage includes vulnerabilities and defense across multiple levels, with basic abstractions of cryptographic services and primitives such as public key cryptography, block ciphers and digital signatures. Experts from engineering introduce to some IMD systems that have  recently been proposed and developed. Experts from Computer Security and Cryptography present new research, which shows vulnerabilities in existing IMDs and proposes solutions. Experts from Privacy Technology and Policy will discuss the societal, legal and ethical challenges surrounding IMD security as well as technological solutions that build on the latest in C...

  19. Do we have to Include HCI Issues in Clinical Trials of Medical Devices?

    DEFF Research Database (Denmark)

    Nielsen, Lene; Christensen, Lars Rune; Sabers, Anne

    2017-01-01

    Digital devices play an important role in medical treatment and will in the future play a larger role in connection to cures of health-related issues. Traditionally medicine has been tested by clinical double blind, randomized trials to document the efficacy and safety profile. When it comes to t...

  20. Definition of information technology architectures for continuous data management and medical device integration in diabetes.

    Science.gov (United States)

    Hernando, M Elena; Pascual, Mario; Salvador, Carlos H; García-Sáez, Gema; Rodríguez-Herrero, Agustín; Martínez-Sarriegui, Iñaki; Gómez, Enrique J

    2008-09-01

    The growing availability of continuous data from medical devices in diabetes management makes it crucial to define novel information technology architectures for efficient data storage, data transmission, and data visualization. The new paradigm of care demands the sharing of information in interoperable systems as the only way to support patient care in a continuum of care scenario. The technological platforms should support all the services required by the actors involved in the care process, located in different scenarios and managing diverse information for different purposes. This article presents basic criteria for defining flexible and adaptive architectures that are capable of interoperating with external systems, and integrating medical devices and decision support tools to extract all the relevant knowledge to support diabetes care.

  1. Telemetry and Telestimulation via Implanted Devices Necessary in Long-Term Experiments Using Conscious Untethered Animals for the Development of New Medical Treatments

    Science.gov (United States)

    Sugimachi, Masaru; Kawada, Toru; Uemura, Kazunori

    Effective countermeasures against explosive increase in healthcare expenditures are urgently needed. A paradigm shift in healthcare is called for, and academics and governments worldwide are working hard on the application of information and communication technologies (ICT) as a feasible and effective measure for reducing medical cost. The more prevalent the disease and the easier disease outcome can be improved, the more efficient is medical ICT in reducing healthcare cost. Hypertension and diabetes mellitus are such examples. Chronic heart failure is another disease in which patients may benefit from ICT-based medical practice. It is conceivable that daily monitoring of hemodynamics together with appropriate treatments may obviate the expensive hospitalization. ICT potentially permit continuous monitoring with wearable or implantable medical devices. ICT may also help accelerate the development of new therapeutic devices. Traditionally effectiveness of treatments is sequentially examined by sacrificing a number of animals at a given time point. These inefficient and inaccurate methods can be replaced by applying ICT to the devices used in chronic animal experiments. These devices allow researchers to obtain biosignals and images from live animals without killing them. They include implantable telemetric devices, implantable telestimulation devices, and imaging devices. Implanted rather than wired monitoring and stimulation devices permit experiments to be conducted under even more physiological conditions, i.e., untethered, free-moving states. Wireless communication and ICT are indispensible technologies for the development of such telemetric and telestimulation devices.

  2. TU-AB-204-02: Device Adverse Events and Compliance

    International Nuclear Information System (INIS)

    Gonzales, S.

    2016-01-01

    The responsibilities of the Food and Drug Administration (FDA) have increased since the inception of the Food and Drugs Act in 1906. Medical devices first came under comprehensive regulation with the passage of the 1938 Food, Drug, and Cosmetic Act. In 1971 FDA also took on the responsibility for consumer protection against unnecessary exposure to radiation-emitting devices for home and occupational use. However it was not until 1976, under the Medical Device Regulation Act, that the FDA was responsible for the safety and effectiveness of medical devices. This session will be presented by the Division of Radiological Health (DRH) and the Division of Imaging, Diagnostics, and Software Reliability (DIDSR) from the Center for Devices and Radiological Health (CDRH) at the FDA. The symposium will discuss on how we protect and promote public health with a focus on medical physics applications organized into four areas: pre-market device review, post-market surveillance, device compliance, current regulatory research efforts and partnerships with other organizations. The pre-market session will summarize the pathways FDA uses to regulate the investigational use and commercialization of diagnostic imaging and radiation therapy medical devices in the US, highlighting resources available to assist investigators and manufacturers. The post-market session will explain the post-market surveillance and compliance activities FDA performs to monitor the safety and effectiveness of devices on the market. The third session will describe research efforts that support the regulatory mission of the Agency. An overview of our regulatory research portfolio to advance our understanding of medical physics and imaging technologies and approaches to their evaluation will be discussed. Lastly, mechanisms that FDA uses to seek public input and promote collaborations with professional, government, and international organizations, such as AAPM, International Electrotechnical Commission (IEC

  3. TU-AB-204-02: Device Adverse Events and Compliance

    Energy Technology Data Exchange (ETDEWEB)

    Gonzales, S. [Food & Drug Administration (United States)

    2016-06-15

    The responsibilities of the Food and Drug Administration (FDA) have increased since the inception of the Food and Drugs Act in 1906. Medical devices first came under comprehensive regulation with the passage of the 1938 Food, Drug, and Cosmetic Act. In 1971 FDA also took on the responsibility for consumer protection against unnecessary exposure to radiation-emitting devices for home and occupational use. However it was not until 1976, under the Medical Device Regulation Act, that the FDA was responsible for the safety and effectiveness of medical devices. This session will be presented by the Division of Radiological Health (DRH) and the Division of Imaging, Diagnostics, and Software Reliability (DIDSR) from the Center for Devices and Radiological Health (CDRH) at the FDA. The symposium will discuss on how we protect and promote public health with a focus on medical physics applications organized into four areas: pre-market device review, post-market surveillance, device compliance, current regulatory research efforts and partnerships with other organizations. The pre-market session will summarize the pathways FDA uses to regulate the investigational use and commercialization of diagnostic imaging and radiation therapy medical devices in the US, highlighting resources available to assist investigators and manufacturers. The post-market session will explain the post-market surveillance and compliance activities FDA performs to monitor the safety and effectiveness of devices on the market. The third session will describe research efforts that support the regulatory mission of the Agency. An overview of our regulatory research portfolio to advance our understanding of medical physics and imaging technologies and approaches to their evaluation will be discussed. Lastly, mechanisms that FDA uses to seek public input and promote collaborations with professional, government, and international organizations, such as AAPM, International Electrotechnical Commission (IEC

  4. Preparation and Characterization of an Advanced Medical Device for Bone Regeneration

    OpenAIRE

    Dorati, Rossella; Colonna, Claudia; Genta, Ida; Bruni, Giovanna; Visai, Livia; Conti, Bice

    2013-01-01

    Tridimensional scaffolds can promote bone regeneration as a framework supporting the migration of cells from the surrounding tissue into the damaged tissue and as delivery systems for the controlled or prolonged release of cells, genes, and growth factors. The goal of the work was to obtain an advanced medical device for bone regeneration through coating a decellularized and deproteinized bone matrix of bovine origin with a biodegradable, biocompatible polymer, to improve the cell engraftment...

  5. Security Mechanism Based on Hospital Authentication Server for Secure Application of Implantable Medical Devices

    Science.gov (United States)

    2014-01-01

    After two recent security attacks against implantable medical devices (IMDs) have been reported, the privacy and security risks of IMDs have been widely recognized in the medical device market and research community, since the malfunctioning of IMDs might endanger the patient's life. During the last few years, a lot of researches have been carried out to address the security-related issues of IMDs, including privacy, safety, and accessibility issues. A physician accesses IMD through an external device called a programmer, for diagnosis and treatment. Hence, cryptographic key management between IMD and programmer is important to enforce a strict access control. In this paper, a new security architecture for the security of IMDs is proposed, based on a 3-Tier security model, where the programmer interacts with a Hospital Authentication Server, to get permissions to access IMDs. The proposed security architecture greatly simplifies the key management between IMDs and programmers. Also proposed is a security mechanism to guarantee the authenticity of the patient data collected from IMD and the nonrepudiation of the physician's treatment based on it. The proposed architecture and mechanism are analyzed and compared with several previous works, in terms of security and performance. PMID:25276797

  6. Security mechanism based on Hospital Authentication Server for secure application of implantable medical devices.

    Science.gov (United States)

    Park, Chang-Seop

    2014-01-01

    After two recent security attacks against implantable medical devices (IMDs) have been reported, the privacy and security risks of IMDs have been widely recognized in the medical device market and research community, since the malfunctioning of IMDs might endanger the patient's life. During the last few years, a lot of researches have been carried out to address the security-related issues of IMDs, including privacy, safety, and accessibility issues. A physician accesses IMD through an external device called a programmer, for diagnosis and treatment. Hence, cryptographic key management between IMD and programmer is important to enforce a strict access control. In this paper, a new security architecture for the security of IMDs is proposed, based on a 3-Tier security model, where the programmer interacts with a Hospital Authentication Server, to get permissions to access IMDs. The proposed security architecture greatly simplifies the key management between IMDs and programmers. Also proposed is a security mechanism to guarantee the authenticity of the patient data collected from IMD and the nonrepudiation of the physician's treatment based on it. The proposed architecture and mechanism are analyzed and compared with several previous works, in terms of security and performance.

  7. Use of technical skills and medical devices among new registered nurses: A questionnaire study.

    Science.gov (United States)

    Ewertsson, Mona; Gustafsson, Margareta; Blomberg, Karin; Holmström, Inger K; Allvin, Renée

    2015-12-01

    One comprehensive part of nursing practice is performing technical skills and handling of medical equipment. This might be challenging for new registered nurses (RNs) to do in patient-safe way. The aim of this study was to describe and compare the extent to which new RNs perform various technical skills and handle medical devices in different settings, and to investigate their possibility for continued learning in this respect. A further aim was to describe their perceptions of incident reporting related to technical skills and medical devices. A cross-sectional study with descriptive and comparative design. RNs who recently graduated from a nursing programme at three Swedish universities and had worked as a RN for up to 1 year were included in the study (n=113, response rate 57%). Data were collected by means of a postal questionnaire. Half of the RNs reported that they performed several of the listed tasks every day or every week, regardless of workplace. These tasks were most frequently performed in surgical departments. The majority of the participants (76%) stated a need of continued practical training. However, less than half of them (48%) had access to a training environment. Several participants (43%) had been involved in incidents related to technical skills or medical devices, which were not always reported. Nearly a third of the participants (31%) did not use the existing guidelines when performing technical skills, and reflection on performance was uncommon. This study highlights the importance of shared responsibilities between nurse educators and health care employers to provide learning opportunities for new RNs in technical skills, to maintain patient safety. To increase the safety culture where nursing students and new RNs understand the importance of using evidence-based guidelines and taking a reflective approach in the performance of technical tasks is needed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Identifying optimal postmarket surveillance strategies for medical and surgical devices: implications for policy, practice and research.

    Science.gov (United States)

    Gagliardi, Anna R; Umoquit, Muriah; Lehoux, Pascale; Ross, Sue; Ducey, Ariel; Urbach, David R

    2013-03-01

    Non-drug technologies offer many benefits, but have been associated with adverse events, prompting calls for improved postmarket surveillance. There is little empirical research to guide the development of such a system. The purpose of this study was to identify optimal postmarket surveillance strategies for medical and surgical devices. Qualitative methods were used for sampling, data collection and analysis. Stakeholders from Canada and the USA representing different roles and perspectives were first interviewed to identify examples and characteristics of different surveillance strategies. These stakeholders and others they recommended were then assembled at a 1-day nominal group meeting to discuss and prioritise the components of a postmarket device surveillance system, and research needed to achieve such a system. Consultations were held with 37 participants, and 47 participants attended the 1-day meeting. They recommended a multicomponent system including reporting by facilities, clinicians and patients, supported with some external surveillance for validation and real-time trials for high-risk devices. Many considerations were identified that constitute desirable characteristics of, and means by which to implement such a system. An overarching network was envisioned to broker linkages, establish a shared minimum dataset, and support communication and decision making. Numerous research questions were identified, which could be pursued in tandem with phased implementation of the system. These findings provide unique guidance for establishing a device safety network that is based on existing initiatives, and could be expanded and evaluated in a prospective, phased fashion as it was developed.

  9. Patient perceptions regarding the use of smart devices for medical photography: results of a patient-based survey.

    Science.gov (United States)

    Nair, Akshay Gopinathan; Potdar, Nayana A; Dadia, Suchit; Aulakh, Simranjeet; Ali, Mohammad Javed; Shinde, Chhaya A

    2018-03-06

    To assess patient perceptions regarding medical photography and the use of smart devices, namely mobile phones and tablets for medical photography. A questionnaire-based survey was conducted among 280 consecutive adult patients who presented to the oculoplastics clinic at a tertiary eye care centre. The responses were tabulated and analysed. Of the 280 patients surveyed, 68% felt that medical photography had a positive impact on their understanding of their illnesses and 72% felt that the use of smartphones for medical photography was acceptable. Respondents below the age of 40 years were more likely to approve of the use of mobile phones for photography as compared to those over 40. Most patients (74%) preferred a doctor to be the person photographing them. While a majority approved of doctors and trainee physicians having access to their photographs, they felt non-physician healthcare personnel should not have access to clinical photographs. Also, 72% of the respondents felt that the patient's consent should be taken before using their photographs. It was noted that patient identification and breach of confidentiality could be some of the potential issues with using smart devices as cameras in the clinic. Clinical photography in general and, specifically, using smart devices for clinical photographs have gained acceptance among patients. The outcomes of this study may be utilized to create policy guidelines for the use of smart devices as photography tools in the clinics. The findings of this survey can also help to create standardized, uniform patient consent forms for clinical photography.

  10. 75 FR 51829 - Public Workshop on Medical Devices and Nanotechnology: Manufacturing, Characterization, and...

    Science.gov (United States)

    2010-08-23

    ... hotel at 301-977-8900 or refer to their Web page at: www.gaithersburg.hilton.com . Contact Person: Daya... provide public comments, time permitting. If you need special accommodations due to a disability, please... refer to the meeting registration Web page at http://www.fda.gov/MedicalDevices/NewsEvents/Workshops...

  11. Development of a handmade device for collimation and central ray alignment tests in medical X-ray equipment; Desenvolvimento de um dispositivo artesanal para os testes de colimação e alinhamento do raio central em equipamentos médicos de raios X

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, B.L. da; Brito, E.B.; Gomes, A.S., E-mail: elizabethberbr@live.com [Universidade José de Souza Herdy (UNINGRANRIO), Nova Iguaçu, RJ (Brazil)

    2017-07-01

    Ordinance 453/98 of the Ministry of Health establishes that medical X-ray equipment should be monitored by tests that prove its efficiency. This practice is called quality control (QC), and two important tests jointly evaluate the operation of the collimation and alignment systems of the central axis of the X-ray beam. The low supply and the high cost generate allegations of difficulties in the periodic realization of the tests. The aim of this work is to design, make and evaluate the performance of a handmade device for the mentioned tests, using low cost materials. Once built, the device had its performance evaluated and compared with the traditionally marketed device. The handmade device proved to be fit in its functions. It is possible to make a device that tests X-ray medical equipment, using the radiology technologist himself as the test runner. Radiation protection is promoted and legislation with no real financial burden.

  12. Registry Assessment of Peripheral Interventional Devices (RAPID): Registry assessment of peripheral interventional devices core data elements.

    Science.gov (United States)

    Jones, W Schuyler; Krucoff, Mitchell W; Morales, Pablo; Wilgus, Rebecca W; Heath, Anne H; Williams, Mary F; Tcheng, James E; Marinac-Dabic, J Danica; Malone, Misti L; Reed, Terrie L; Fukaya, Rie; Lookstein, Robert A; Handa, Nobuhiro; Aronow, Herbert D; Bertges, Daniel J; Jaff, Michael R; Tsai, Thomas T; Smale, Joshua A; Zaugg, Margo J; Thatcher, Robert J; Cronenwett, Jack L

    2018-02-01

    The current state of evaluating patients with peripheral artery disease and more specifically of evaluating medical devices used for peripheral vascular intervention (PVI) remains challenging because of the heterogeneity of the disease process, the multiple physician specialties that perform PVI, the multitude of devices available to treat peripheral artery disease, and the lack of consensus about the best treatment approaches. Because PVI core data elements are not standardized across clinical care, clinical trials, and registries, aggregation of data across different data sources and physician specialties is currently not feasible. Under the auspices of the U.S. Food and Drug Administration's Medical Device Epidemiology Network initiative-and its PASSION (Predictable and Sustainable Implementation of the National Registries) program, in conjunction with other efforts to align clinical data standards-the Registry Assessment of Peripheral Interventional Devices (RAPID) workgroup was convened. RAPID is a collaborative, multidisciplinary effort to develop a consensus lexicon and to promote interoperability across clinical care, clinical trials, and national and international registries of PVI. The current manuscript presents the initial work from RAPID to standardize clinical data elements and definitions, to establish a framework within electronic health records and health information technology procedural reporting systems, and to implement an informatics-based approach to promote the conduct of pragmatic clinical trials and registry efforts in PVI. Ultimately, we hope this work will facilitate and improve device evaluation and surveillance for patients, clinicians, health outcomes researchers, industry, policymakers, and regulators. Copyright © 2017 Society for Vascular Surgery. All rights reserved.

  13. Evaluation of the Quality Control Program for Diagnostic Radiography and Fluoroscopy Devices in Syria during 2005-2013

    Directory of Open Access Journals (Sweden)

    M. H. Kharita

    2017-06-01

    Full Text Available Introduction: Extensive use of diagnostic radiology is the largest contributor to total population radiation doses. Thus, appropriate equipment and safe practice are necessary for good-quality images with optimal doses. This study aimed to perform quality control (QC audit for radiography and fluoroscopy devices owned by private sector in Syria (2005-2013 to verify compliance of performance of X-ray machines with the regulatory requirements stipulated by the national regulatory body. Materials and Methods: In this study, QC audit included 487 X-ray diagnostic machines, (363 radiography and 124 fluoroscopy devices, installed in 306 medical diagnostic radiology centers in 14 provinces in Syria. We employed an X-ray beam analyzer device (NERO model 8000, Victoreen, USA, which was tested and calibrated at the National Secondary Standard Dosimetry Laboratory traceable to the IAEA Network of Secondary Standard Dosimetry Laboratories. Standard QC tool kits were used to evaluate tube and generator of the X-ray machines, which constituted potential (kVp, timer accuracy, radiation output consistency, tube filtration, small and large focal spot sizes, X-ray beam collimation and alignment, as well as high- and low-resolution and entrance surface dose in fluoroscopy. Results: According to our results, most of the assessed operating parameters were in compliance with the standards stipulated by the National Regulatory Authority. In cases of noncompliance for the assessed parameters, maximum value (28.77% pertained to accuracy of kVp calibration for radiography units, while the lowest value (2.42% belonged to entrance surface dose in fluoroscopy systems. Conclusion: Effective QC program in diagnostic radiology leads to obtaining information regarding quality of radiology devices used for medical diagnosis and minimizing the doses received by patients and medical personnel. The findings of this QC program, as the main part of QA program, illustrated that most

  14. Power Factor Improvement Using Automatic Power Factor Compensation (APFC Device for Medical Industries in Malaysia

    Directory of Open Access Journals (Sweden)

    Zaidi Maryam Nabihah

    2018-01-01

    Full Text Available This paper present the project designed to correcting power factor for medical industries in Malaysia automatically. Which with hope to make the cost and energy usage efficient, because the energy source are depleting due to increase in population. Power factor is the ratio of real power and apparent power. This definition is mathematically represented as kW/kVA where kW is active power and kVA is apparent power (active + reactive. Reactive power is the non-working power generated by the magnetic and inductive load to generate magnetic flux. The increase in reactive power increase the apparent power so the power factor will decrease. Low pF will cause the industry to meet high demand thus making it less efficient. The main aim of this project is to increasing the current power factor of medical industries from 0.85 to 0.90. Power factor compensation contribute to reduction in current-dependent losses and increase energy efficiency while expanding the reliability of planning for future energy network. As technology develops, the gradual cost and efficiency penalty should reduce. Therefore, automatic power factor compensation device should become cost-effective and smaller device over time. That is the reason this project is using programmable device as it is a miniature architecture device.

  15. Audiologic and subjective evaluation of Baha® Attract device.

    Science.gov (United States)

    Pérez-Carbonell, Tomàs; Pla-Gil, Ignacio; Redondo-Martínez, Jaume; Morant-Ventura, Antonio; García-Callejo, Francisco Javier; Marco-Algarra, Jaime

    We included 9 patients implanted with Baha ® Attract. All our patients were evaluated by free field tonal audiometry, free field verbal audiometry and free field verbal audiometry with background noise, all the tests were performed with and without the device. To evaluate the subjective component of the implantation, we used the Glasgow Benefit Inventory (GBI) and Abbreviated Profile of Hearing Aid Benefit (APHAB). The auditive assessment with the device showed average auditive thresholds of 35.8dB with improvements of 25.8dB over the previous situation. Speech reception thresholds were 37dB with Baha ® Attract, showing improvements of 23dB. Maximum discrimination thresholds showed an average gain of 60dB with the device. Baha ® Attract achieves auditive improvements in patients for whom it is correctly indicated, with a consequent positive subjective evaluation. This study shows the attenuation effect in transcutaneous transmission, that prevents the device achieving greater improvements. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  16. Pricing of medical devices under coverage uncertainty--a modelling approach.

    Science.gov (United States)

    Girling, Alan J; Lilford, Richard J; Young, Terry P

    2012-12-01

    Product vendors and manufacturers are increasingly aware that purchasers of health care will fund new clinical treatments only if they are perceived to deliver value-for-money. This influences companies' internal commercial decisions, including the price they set for their products. Other things being equal, there is a price threshold, which is the maximum price at which the device will be funded and which, if its value were known, would play a central role in price determination. This paper examines the problem of pricing a medical device from the vendor's point of view in the presence of uncertainty about what the price threshold will be. A formal solution is obtained by maximising the expected value of the net revenue function, assuming a Bayesian prior distribution for the price threshold. A least admissible price is identified. The model can also be used as a tool for analysing proposed pricing policies when no formal prior specification of uncertainty is available. Copyright © 2011 John Wiley & Sons, Ltd.

  17. From Paper to PDA: Design and Evaluation of a Clinical Ward Instruction on a Mobile Device

    Science.gov (United States)

    Kanstrup, Anne Marie; Stage, Jan

    Mobile devices with small screens and minimal facilities for interaction are increasingly being used in complex human activities for accessing and processing information, while the user is moving. This paper presents a case study of the design and evaluation of a mobile system, which involved transformation of complex text and tables to digital format on a PDA. The application domain was an emergency medical ward, and the user group was junior registrars. We designed a PDA-based system for accessing information, focusing on the ward instruction, implemented a prototype and evaluated it for usability and utility. The evaluation results indicate significant problems in the interaction with the system as well as the extent to which the system is useful for junior registrars in their daily work.

  18. Effects of sterilization on the mechanical properties of poly(methyl methacrylate) based personalized medical devices.

    Science.gov (United States)

    Münker, T J A G; van de Vijfeijken, S E C M; Mulder, C S; Vespasiano, V; Becking, A G; Kleverlaan, C J; Becking, A G; Dubois, L; Karssemakers, L H E; Milstein, D M J; van de Vijfeijken, S E C M; Depauw, P R A M; Hoefnagels, F W A; Vandertop, W P; Kleverlaan, C J; Münker, T J A G; Maal, T J J; Nout, E; Riool, M; Zaat, S A J

    2018-05-01

    Nowadays, personalized medical devices are frequently used for patients. Due to the manufacturing procedure sterilization is required. How different sterilization methods affect the mechanical behavior of these devices is largely unknown. Three poly(methyl methacrylate) (PMMA) based materials (Vertex Self-Curing, Palacos R+G, and NextDent C&B MFH) were sterilized with different sterilization methods: ethylene oxide, hydrogen peroxide gas plasma, autoclavation, and γ-irradiation. Mechanical properties were determined by testing the flexural strength, flexural modulus, fracture toughness, and impact strength. The flexural strength of all materials was significantly higher after γ-irradiation compared to the control and other sterilization methods, as tested in a wet environment. NextDent C&B MFH showed the highest flexural and impact strength, Palacos R+G showed the highest maximum stress intensity factor and total fracture work. Autoclave sterilization is not suitable for the sterilization of PMMA-based materials. Ethylene oxide, hydrogen peroxide gas plasma, and γ-irradiation appear to be suitable techniques to sterilize PMMA-based personalized medical devices. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. Differential effects of public and private funding in the medical device industry.

    Science.gov (United States)

    Kang, Hyunsung D; Ku, David N

    2018-02-01

    Funding for scientific advancement comes from two dominant sources: public funds used to generate knowledge, and private sector funds in the pursuit of commercial products. It is unclear how to compare the outputs of these two financial mechanisms because both sectors are motivated by common goods but are also governed by divergent forces. Employment within a geographic region may be a metric of mutual value that can be applied equally to assess the societal impacts of two financing sources. Areas covered: The authors focused on the medical device industry, which is a robust sector of growth for the U.S. economy. The U.S. NIH and venture capital community are representatives of public and private capital, respectively. Using a longitudinal employment dataset of 247 distinct locations, the authors found that NIH funding tends to create more jobs directly compared to venture capital funding. Moreover, the indirect effect of governmental funding is initially smaller than that of venture capital funding for the first two years, but eventually surpasses that of venture capital funding. Expert commentary: These findings imply that policy decisions regarding financial allocations in the medical device industry should consider the appropriate typology of financial capital and its consequences.

  20. Linking the Regulatory and Reimbursement Processes for Medical Devices : The Need for Integrated Assessments

    NARCIS (Netherlands)

    Ciani, Oriana; Wilcher, Britni; van Giessen, Anoukh; Taylor, Rod S.

    2017-01-01

    Much criticism has been directed at the licencing requirements for medical devices (MDs) as they often result in a lack of robust evidence to inform health technology assessment (HTA) decisions. To better understand the current international decisional framework on MD technologies, we undertook