WorldWideScience

Sample records for medical device development

  1. Medical device development.

    Science.gov (United States)

    Panescu, Dorin

    2009-01-01

    The development of a successful medical product requires not only engineering design efforts, but also clinical, regulatory, marketing and business expertise. This paper reviews items related to the process of designing medical devices. It discusses the steps required to take a medical product idea from concept, through development, verification and validation, regulatory approvals and market release.

  2. Legislative aspects of the development of medical devices.

    Science.gov (United States)

    Marešová, Petra; Klímová, Blanka; Krejcar, Ondřej; Kuča, Kamil

    2015-09-01

    European industry of medical device technologies represents 30% of all worlds sales. New health technologies bring effective treatment approaches, help shorten stays in hospital1),bring better treatment results and accelerate rehabilitation which leads to the earlier patients recovery.Legislative aspects are one of the key areas influencing the speed of development of medical devices and their launching. The aim of this article is to specify current state of legislation in the development of medical devices in the European Union in comparison with the market leaders such as China, Japan and USA.The best established market of medical devices is in the USA. Both Japan and China follow the USA model. However, a non-professional code of ethics in China in some respect contributes to the decrease of quality of medical devices, while Japan as well as the EU countries try really hard to conform to all the regulations imposed on the manufacturing of medical devices.

  3. Development of Implantable Medical Devices: From an Engineering Perspective

    Directory of Open Access Journals (Sweden)

    Yeun-Ho Joung

    2013-09-01

    Full Text Available From the first pacemaker implant in 1958, numerous engineering and medical activities for implantable medical device development have faced challenges in materials, battery power, functionality, electrical power consumption, size shrinkage, system delivery, and wireless communication. With explosive advances in scientific and engineering technology, many implantable medical devices such as the pacemaker, cochlear implant, and real-time blood pressure sensors have been developed and improved. This trend of progress in medical devices will continue because of the coming super-aged society, which will result in more consumers for the devices. The inner body is a special space filled with electrical, chemical, mechanical, and marine-salted reactions. Therefore, electrical connectivity and communication, corrosion, robustness, and hermeticity are key factors to be considered during the development stage. The main participants in the development stage are the user, the medical staff, and the engineer or technician. Thus, there are three different viewpoints in the development of implantable devices. In this review paper, considerations in the development of implantable medical devices will be presented from the viewpoint of an engineering mind.

  4. Practice of Regulatory Science (Development of Medical Devices).

    Science.gov (United States)

    Niimi, Shingo

    2017-01-01

    Prototypes of medical devices are made in accordance with the needs of clinical practice, and for systems required during the initial process of medical device development for new surgical practices. Verification of whether these prototypes produce the intended performance specifications is conducted using basic tests such as mechanical and animal tests. The prototypes are then improved and modified until satisfactory results are obtained. After a prototype passes through a clinical trial process similar to that for new drugs, application for approval is made. In the approval application process, medical devices are divided into new, improved, and generic types. Reviewers judge the validity of intended use, indications, operation procedures, and precautions, and in addition evaluate the balance between risk and benefit in terms of efficacy and safety. Other characteristics of medical devices are the need for the user to attain proficiency in usage techniques to ensure efficacy and safety, and the existence of a variety of medical devices for which assessment strategies differ, including differences in impact on the body in cases in which a physical burden to the body or failure of a medical device develops. Regulatory science of medical devices involves prediction, judgment, and evaluation of efficacy, safety, and quality, from which data result which can become indices in the development stages from design to application for approval. A reduction in the number of animals used for testing, improvement in efficiency, reduction of the necessity for clinical trials, etc. are expected through rational setting of evaluation items.

  5. Cybersecurity and the Medical Device Product Development Lifecycle.

    Science.gov (United States)

    Jones, Richard W; Katzis, Konstantinos

    2017-01-01

    Protecting connected medical devices from evolving cyber related threats, requires a continuous lifecycle approach whereby cybersecurity is integrated within the product development lifecycle and both complements and re-enforces the safety risk management processes therein. This contribution reviews the guidance relating to medical device cybersecurity within the product development lifecycle.

  6. The current situation and development of medical device testing institutes in China.

    Science.gov (United States)

    Yang, Xiaofang; Mu, Ruihong; Fan, Yubo; Wang, Chunren; Li, Deyu

    2017-04-01

    This article analyses the current situation and development of Chinese medical device testing institutes from the perspectives of the two most important functions - testing functions and medical device standardization functions. Areas Covered: The objective of the Chinese government regulations for medical device industry is to ensure the safety and effectiveness of medical devices for Chinese patients. To support the regulation system, the Chinese government has established medical device testing institutes at different levels for example, the national, provincial, and municipal levels. These testing institutes also play an important role in technical support during medical device premarket registration and post market surveillance, they are also the vital practitioners of Chinese medical device standardization. Expert Commentary: Chinese medical device testing institutes are technical departments established by government, and serve the regulatory functions of government agency. In recent years, with the rapid development of medical device industry as well as constantly increasing international and domestic medical device market, the importance of medical device testing institute is more prominent, However, there are still some problems unsolved, such as their overall capacity remains to be improved, construction of standardization is to be strengthened, etc.

  7. Developing medical device software in compliance with regulations.

    Science.gov (United States)

    Zema, M; Rosati, S; Gioia, V; Knaflitz, M; Balestra, G

    2015-08-01

    In the last decade, the use of information technology (IT) in healthcare has taken a growing role. In fact, the adoption of an increasing number of computer tools has led to several benefits related to the process of patient care and allowed easier access to social and health care resources. At the same time this trend gave rise to new challenges related to the implementation of these new technologies. Software used in healthcare can be classified as medical devices depending on the way they are used and on their functional characteristics. If they are classified as medical devices they must satisfy specific regulations. The aim of this work is to present a software development framework that can allow the production of safe and high quality medical device software and to highlight the correspondence between each software development phase and the appropriate standard and/or regulation.

  8. Medical device development: managing conflicts of interest encountered by physicians.

    Science.gov (United States)

    Baim, Donald S; Donovan, Aine; Smith, John J; Briefs, Nancy; Geoffrion, Richard; Feigal, David; Kaplan, Aaron V

    2007-04-01

    New technologies introduced over the past three decades have transformed medical diagnosis and treatment, and significantly improved patient outcomes. These changes have been mediated by the introduction of new medical devices, particularly for the treatment of cardiovascular, orthopedic, and ophthalmic disorders. These devices, in turn, have created large markets and spawned a burgeoning medical device industry, including six Fortune 500 companies whose combined market capitalization now exceeds 400 billion dollars. This success story, which has unquestionably benefited patients and society alike, has been dependent upon an intense collaboration among industry, clinicians, and regulatory authorities. However, when physicians actively involved in patient care participate in such collaborations, they are increasingly vulnerable to creating potential conflicts between these two (clinical and device development) roles. Such conflicts, which may ultimately erode public trust, have important consequences not only for the individual physicians, but also for their parent institutions, their patients, sponsoring companies, and the entire clinical research enterprise that makes the development and introduction of new devices possible. The third Dartmouth Device Development Symposium held in October 2005 brought together thought leaders within the medical device community, including academicians, clinical investigators, regulators from the Food and Drug Administration and Centers for Medicare and Medicaid Services (CMS), large and small device manufacturers and the financial (venture capital and investment banks) community. The Symposium examined the conflicts of interest encountered during the early development and commercialization of a medical device. The goal of these discussions was to (1) identify and characterize the conflicts that arise and (2) provide strategies to address these conflicts. This manuscript was prepared by a writing committee to provide a summary

  9. Medical device software: defining key terms.

    Science.gov (United States)

    Pashkov, Vitalii; Gutorova, Nataliya; Harkusha, Andrii

    one of the areas of significant growth in medical devices has been the role of software - as an integral component of a medical device, as a standalone device and more recently as applications on mobile devices. The risk related to a malfunction of the standalone software used within healthcare is in itself not a criterion for its qualification or not as a medical device. It is therefore, necessary to clarify some criteria for the qualification of stand-alone software as medical devices Materials and methods: Ukrainian, European Union, United States of America legislation, Guidelines developed by European Commission and Food and Drug Administration's, recommendations represented by international voluntary group and scientific works. This article is based on dialectical, comparative, analytic, synthetic and comprehensive research methods. the legal regulation of software which is used for medical purpose in Ukraine limited to one definition. In European Union and United States of America were developed and applying special guidelines that help developers, manufactures and end users to difference software on types standing on medical purpose criteria. Software becomes more and more incorporated into medical devices. Developers and manufacturers may not have initially appreciated potential risks to patients and users such situation could have dangerous results for patients or users. It is necessary to develop and adopt the legislation that will intend to define the criteria for the qualification of medical device software and the application of the classification criteria to such software, provide some illustrative examples and step by step recommendations to qualify software as medical device.

  10. Medical devices regulations, standards and practices

    CERN Document Server

    Ramakrishna, Seeram; Wang, Charlene

    2015-01-01

    Medical Devices and Regulations: Standards and Practices will shed light on the importance of regulations and standards among all stakeholders, bioengineering designers, biomaterial scientists and researchers to enable development of future medical devices. Based on the authors' practical experience, this book provides a concise, practical guide on key issues and processes in developing new medical devices to meet international regulatory requirements and standards. Provides readers with a global perspective on medical device regulationsConcise and comprehensive information on how to desig

  11. Effects of Medical Device Regulations on the Development of Stand-Alone Medical Software: A Pilot Study.

    Science.gov (United States)

    Blagec, Kathrin; Jungwirth, David; Haluza, Daniela; Samwald, Matthias

    2018-01-01

    Medical device regulations which aim to ensure safety standards do not only apply to hardware devices but also to standalone medical software, e.g. mobile apps. To explore the effects of these regulations on the development and distribution of medical standalone software. We invited a convenience sample of 130 domain experts to participate in an online survey about the impact of current regulations on the development and distribution of medical standalone software. 21 respondents completed the questionnaire. Participants reported slight positive effects on usability, reliability, and data security of their products, whereas the ability to modify already deployed software and customization by end users were negatively impacted. The additional time and costs needed to go through the regulatory process were perceived as the greatest obstacles in developing and distributing medical software. Further research is needed to compare positive effects on software quality with negative impacts on market access and innovation. Strategies for avoiding over-regulation while still ensuring safety standards need to be devised.

  12. Pediatric medical device development by surgeons via capstone engineering design programs.

    Science.gov (United States)

    Sack, Bryan S; Elizondo, Rodolfo A; Huang, Gene O; Janzen, Nicolette; Espinoza, Jimmy; Sanz-Cortes, Magdalena; Dietrich, Jennifer E; Hakim, Julie; Richardson, Eric S; Oden, Maria; Hanks, John; Haridas, Balakrishna; Hury, James F; Koh, Chester J

    2018-03-01

    There is a need for pediatric medical devices that accommodate the unique physiology and anatomy of pediatric patients that is increasingly receiving more attention. However, there is limited literature on the programs within children's hospitals and academia that can support pediatric device development. We describe our experience with pediatric device design utilizing collaborations between a children's hospital and two engineering schools. Utilizing the academic year as a timeline, unmet pediatric device needs were identified by surgical faculty and matched with an engineering mentor and a team of students within the Capstone Engineering Design programs at two universities. The final prototypes were showcased at the end of the academic year and if appropriate, provisional patent applications were filed. All twelve teams successfully developed device prototypes, and five teams obtained provisional patents. The prototypes that obtained provisional patents included a non-operative ureteral stent removal system, an evacuation device for small kidney stone fragments, a mechanical leech, an anchoring system of the chorio-amniotic membranes during fetal surgery, and a fetal oxygenation monitor during fetoscopic procedures. Capstone Engineering Design programs in partnership with surgical faculty at children's hospitals can play an effective role in the prototype development of novel pediatric medical devices. N/A - No clinical subjects or human testing was performed. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Medical Devices

    NARCIS (Netherlands)

    Verkerke, Gijsbertus Jacob; Mahieu, H.F.; Geertsema, A.A.; Hermann, I.F.; van Horn, J.R.; Hummel, J. Marjan; van Loon, J.P.; Mihaylov, D.; van der Plaats, A.; Schraffordt Koops, H.; Schutte, H.K.; Veth, R.P.H.; de Vries, M.P.; Rakhorst, G.; Shi, Donglu

    2004-01-01

    The development of new medical devices is a very time-consuming and costly process. Besides the time between the initial idea and the time that manufacturing and testing of prototypes takes place, the time needed for the development of production facilities, production of test series, marketing,

  14. Medical device-related pressure ulcers

    Directory of Open Access Journals (Sweden)

    Black JM

    2016-08-01

    Full Text Available Joyce M Black,1 Peggy Kalowes2 1Adult Health and Illness Department, College of Nursing, University of Nebraska Medical Center, Omaha, NE, 2Nursing Research and Innovation, Long Beach Memorial Miller Children’s & Women’s Hospital, Long Beach, CA, USA Abstract: Pressure ulcers from medical devices are common and can cause significant morbidity in patients of all ages. These pressure ulcers appear in the shape of the device and are most often found from the use of oxygen delivery devices. A hospital program designed to reduce the number of pressure ulcers from medical devices was successful. The program involved the development of a team that focused on skin, the results were then published for the staff to track their performance, and it was found that using foam dressings helped reduce the pressure from the device. The incidence of ulcers from medical devices has remained at zero at this hospital since this program was implemented. Keywords: pressure ulcer, medical device related

  15. A model of user engagement in medical device development.

    Science.gov (United States)

    Grocott, Patricia; Weir, Heather; Ram, Mala Bridgelal

    2007-01-01

    The purpose of this paper is to address three topical themes: user involvement in health services research; determining the value of new medical technologies in patient care pathways, furthering knowledge related to quality in health and social care; and knowledge exchange between manufacturers, health service supply chain networks and device users. The model is being validated in a case study in progress. The latter is a "proving ground" study for a translational research company. Medical devices play a pivotal role in the management of chronic diseases, across all care settings. Failure to engage users in device development inevitably affects the quality of clinical outcomes. A model of user engagement is presented, turning unmet needs for medical devices into viable commercial propositions. A case study investigating the perceptions of individuals with Epidermolysis Bullosa (EB), their lay and professional carers into unmet needs. EB is an inherited condition affecting the skin and mucosal linings that leads to blistering and wounds. Qualitative data are being collected to generate understanding of unmet needs and wound care products. These needs are being translated into new design concepts and prototypes. Prototypes will be evaluated in an n = 1 experimental design, generating quantitative outcomes data. There are generalisations from the case study, and the model outlined. New products for managing EB wounds can logically benefit other groups. The model is transferable to other clinical problems, which can benefit from research and technological advances that are integral to clinical needs and care.

  16. Surgical tools and medical devices

    CERN Document Server

    Jackson, Mark

    2016-01-01

    This new edition presents information and knowledge on the field of biomedical devices and surgical tools. The authors look at the interactions between nanotechnology, nanomaterials, design, modeling, and tools for surgical and dental applications, as well as how nanostructured surfaces can be created for the purposes of improving cell adhesion between medical devices and the human body. Each original chapter is revised in this second edition and describes developments in coatings for heart valves, stents, hip and knee joints, cardiovascular devices, orthodontic applications, and regenerative materials such as bone substitutes. There are also 8 new chapters that address: Microvascular anastomoses Inhaler devices used for pulmonary delivery of medical aerosols Surface modification of interference screws Biomechanics of the mandible (a detailed case study) Safety and medical devices The synthesis of nanostructured material Delivery of anticancer molecules using carbon nanotubes Nano and micro coatings for medic...

  17. Counterfeit drugs and medical devices in developing countries

    Directory of Open Access Journals (Sweden)

    Glass BD

    2014-03-01

    Full Text Available Beverley D GlassSchool of Pharmacy and Molecular Sciences, James Cook University, Townsville, QLD, AustraliaAbstract: The World Health Organization has reported that counterfeit medicines potentially make up more than 50% of the global drug market, with a significant proportion of these fake products being encountered in developing countries. This occurrence is attributed to a lack of effective regulation and a weak enforcement capacity existing in these countries, with an increase in this trade resulting from the growing size and sophistication of drug counterfeiters. In addition, due to both cost and lack of availability of medicines, consumers in developing countries are more likely to seek out these inexpensive options. The World Health Organization is mindful of the impact of counterfeit drugs on consumer confidence in health care systems, health professionals, the supply chain, and genuine suppliers of medicines and medical devices. Antibiotics, antituberculosis drugs, and antimalarial and antiretroviral drugs are frequently targeted, with reports of 60% of the anti-infective drugs in Asia and Africa containing active pharmaceutical ingredients outside their pharmacopoeial limits. This has obvious public health implications of increasing drug resistance and negating all the efforts that have already gone into the provision of medicines to treat these life threatening conditions in the developing world. This review, while focusing on counterfeit medicines and medical devices in developing countries, will present information on their impact and how these issues can be addressed by regulation and control of the supply chain using technology appropriate to the developing world. The complexity of the problem will also be highlighted in terms of the definition of counterfeit and substandard medicines, including gray pharmaceuticals. Although this issue presents as a global public health problem, outcomes in developing countries where counterfeit

  18. Medical Device Safety

    Science.gov (United States)

    A medical device is any product used to diagnose, cure, or treat a condition, or to prevent disease. They ... may need one in a hospital. To use medical devices safely Know how your device works. Keep ...

  19. Implantable electronic medical devices

    CERN Document Server

    Fitzpatrick, Dennis

    2014-01-01

    Implantable Electronic Medical Devices provides a thorough review of the application of implantable devices, illustrating the techniques currently being used together with overviews of the latest commercially available medical devices. This book provides an overview of the design of medical devices and is a reference on existing medical devices. The book groups devices with similar functionality into distinct chapters, looking at the latest design ideas and techniques in each area, including retinal implants, glucose biosensors, cochlear implants, pacemakers, electrical stimulation t

  20. Implantable Medical Devices

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Implantable Medical Devices Updated:Sep 16,2016 For Rhythm Control ... a Heart Attack Introduction Medications Surgical Procedures Implantable Medical Devices • Life After a Heart Attack • Heart Attack ...

  1. Integration of human factors and ergonomics during medical device design and development: it's all about communication.

    Science.gov (United States)

    Vincent, Christopher James; Li, Yunqiu; Blandford, Ann

    2014-05-01

    Manufacturers of interactive medical devices, such as infusion pumps, need to ensure that devices minimise the risk of unintended harm during use. However, development teams face challenges in incorporating Human Factors. The aim of the research reported here was to better understand the constraints under which medical device design and development take place. We report the results of a qualitative study based on 19 semi-structured interviews with professionals involved in the design, development and deployment of interactive medical devices. A thematic analysis was conducted. Multiple barriers to designing for safety and usability were identified. In particular, we identified barriers to communication both between the development organisation and the intended users and between different teams within the development organisation. We propose the use of mediating representations. Artefacts such as personas and scenarios, known to provide integration across multiple perspectives, are an essential component of designing for safety and usability. Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  2. Analytical Chemistry in the Regulatory Science of Medical Devices.

    Science.gov (United States)

    Wang, Yi; Guan, Allan; Wickramasekara, Samanthi; Phillips, K Scott

    2018-06-12

    In the United States, regulatory science is the science of developing new tools, standards, and approaches to assess the safety, efficacy, quality, and performance of all Food and Drug Administration-regulated products. Good regulatory science facilitates consumer access to innovative medical devices that are safe and effective throughout the Total Product Life Cycle (TPLC). Because the need to measure things is fundamental to the regulatory science of medical devices, analytical chemistry plays an important role, contributing to medical device technology in two ways: It can be an integral part of an innovative medical device (e.g., diagnostic devices), and it can be used to support medical device development throughout the TPLC. In this review, we focus on analytical chemistry as a tool for the regulatory science of medical devices. We highlight recent progress in companion diagnostics, medical devices on chips for preclinical testing, mass spectrometry for postmarket monitoring, and detection/characterization of bacterial biofilm to prevent infections.

  3. Contextual inquiry for medical device design

    CERN Document Server

    Privitera, Mary Beth

    2015-01-01

    Contextual Inquiry for Medical Device Design helps users understand the everyday use of medical devices and the way their usage supports the development of better products and increased market acceptance. The text explains the concept of contextual inquiry using real-life examples to illustrate its application. Case studies provide a frame of reference on how contextual inquiry is successfully used during product design, ultimately producing safer, improved medical devices. Presents the ways contextual inquiry can be used to inform the evaluation and business case of technologyHelps users

  4. Integrating the results of user research into medical device development: insights from a case study.

    Science.gov (United States)

    Martin, Jennifer L; Barnett, Julie

    2012-07-19

    It is well established that considering users is an important aspect of medical device development. However it is also well established that there are numerous barriers to successfully conducting user research and integrating the results into product development. It is not sufficient to simply conduct user research, it must also be effectively integrated into product development. A case study of the development of a new medical imaging device was conducted to examine in detail how users were involved in a medical device development project. Two user research studies were conducted: a requirements elicitation interview study and an early prototype evaluation using contextual inquiry. A descriptive in situ approach was taken to investigate how these studies contributed to the product development process and how the results of this work influenced the development of the technology. Data was collected qualitatively through interviews with the development team, participant observation at development meetings and document analysis. The focus was on investigating the barriers that exist to prevent user data from being integrated into product development. A number of individual, organisational and system barriers were identified that functioned to prevent the results of the user research being fully integrated into development. The user and technological aspects of development were seen as separate work streams during development. The expectations of the developers were that user research would collect requirements for the appearance of the device, rather than challenge its fundamental concept. The manner that the user data was communicated to the development team was not effective in conveying the significance or breadth of the findings. There are a range of informal and formal organisational processes that can affect the uptake of user data during medical device development. Adopting formal decision making processes may assist manufacturers to take a more integrated and

  5. Integrating the results of user research into medical device development: insights from a case study

    Directory of Open Access Journals (Sweden)

    Martin Jennifer L

    2012-07-01

    Full Text Available Abstract Background It is well established that considering users is an important aspect of medical device development. However it is also well established that there are numerous barriers to successfully conducting user research and integrating the results into product development. It is not sufficient to simply conduct user research, it must also be effectively integrated into product development. Methods A case study of the development of a new medical imaging device was conducted to examine in detail how users were involved in a medical device development project. Two user research studies were conducted: a requirements elicitation interview study and an early prototype evaluation using contextual inquiry. A descriptive in situ approach was taken to investigate how these studies contributed to the product development process and how the results of this work influenced the development of the technology. Data was collected qualitatively through interviews with the development team, participant observation at development meetings and document analysis. The focus was on investigating the barriers that exist to prevent user data from being integrated into product development. Results A number of individual, organisational and system barriers were identified that functioned to prevent the results of the user research being fully integrated into development. The user and technological aspects of development were seen as separate work streams during development. The expectations of the developers were that user research would collect requirements for the appearance of the device, rather than challenge its fundamental concept. The manner that the user data was communicated to the development team was not effective in conveying the significance or breadth of the findings. Conclusion There are a range of informal and formal organisational processes that can affect the uptake of user data during medical device development. Adopting formal decision

  6. Safety evaluation in the development of medical devices and combination products

    CERN Document Server

    Gad, Shayne C

    2008-01-01

    Capturing the growth of the global medical device market in recent years, this practical new guide is essential for all who are responsible for ensuring safety in the use and manufacture of medical devices. It has been extensively updated to reflect significant advances, incorporating combination products and helpful case examples of current real-life problems in the field.The Third Edition explores these key current trends:global device marketscontinually advancing technologythe increasing harmonization of device safety regulation worldwideEach aspect of safety evaluation is considered in ter

  7. Towards sustainable design for single-use medical devices.

    Science.gov (United States)

    Hanson, Jacob J; Hitchcock, Robert W

    2009-01-01

    Despite their sophistication and value, single-use medical devices have become commodity items in the developed world. Cheap raw materials along with large scale manufacturing and distribution processes have combined to make many medical devices more expensive to resterilize, package and restock than to simply discard. This practice is not sustainable or scalable on a global basis. As the petrochemicals that provide raw materials become more expensive and the global reach of these devices continues into rapidly developing economies, there is a need for device designs that take into account the total life-cycle of these products, minimize the amount of non-renewable materials consumed and consider alternative hybrid reusable / disposable approaches. In this paper, we describe a methodology to perform life cycle and functional analyses to create additional design requirements for medical devices. These types of sustainable approaches can move the medical device industry even closer to the "triple bottom line"--people, planet, profit.

  8. A concept ideation framework for medical device design.

    Science.gov (United States)

    Hagedorn, Thomas J; Grosse, Ian R; Krishnamurty, Sundar

    2015-06-01

    Medical device design is a challenging process, often requiring collaboration between medical and engineering domain experts. This collaboration can be best institutionalized through systematic knowledge transfer between the two domains coupled with effective knowledge management throughout the design innovation process. Toward this goal, we present the development of a semantic framework for medical device design that unifies a large medical ontology with detailed engineering functional models along with the repository of design innovation information contained in the US Patent Database. As part of our development, existing medical, engineering, and patent document ontologies were modified and interlinked to create a comprehensive medical device innovation and design tool with appropriate properties and semantic relations to facilitate knowledge capture, enrich existing knowledge, and enable effective knowledge reuse for different scenarios. The result is a Concept Ideation Framework for Medical Device Design (CIFMeDD). Key features of the resulting framework include function-based searching and automated inter-domain reasoning to uniquely enable identification of functionally similar procedures, tools, and inventions from multiple domains based on simple semantic searches. The significance and usefulness of the resulting framework for aiding in conceptual design and innovation in the medical realm are explored via two case studies examining medical device design problems. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. CSIR research, development and innovation initiatives for the medical device and diagnostic industry

    CSIR Research Space (South Africa)

    Vilakazi, Busisiwe

    2017-10-01

    Full Text Available This presentation is focused on development and innovation initiatives in the medical device and diagnostic industry. It is presented by Dr Busisiwe Vilakasi at The 6th CSIR Conference: Ideas that work for industrial development, 5-6 October 2017...

  10. Mobile medical device connectivity: real world solutions.

    Science.gov (United States)

    Pettus, Dan

    2004-01-01

    Mobile medical devices, such as infusion pumps, provide an important therapeutic function. They are also valuable sources of information about treatment patterns at the point of care. However, these mobile devices have been independent islands of valuable information, unable to share the data they gather with other hospital information resources on a real time basis. Although data from these devices can provide significant improvements for medical safety and vital information needed for clinical best practice development, gathering that data poses significant challenges when interfacing with hospital information systems. Mobile medical devices move from place to place as independent actors, raising a series of security and identification issues when they need to be disconnected and reconnected using traditional tethered cable connections. The continuing lack of accepted communications protocol standards, in spite of the concentrated efforts of organizations like the IEEE and the Medical Information Bus (IEEE 1073) to establish them, has made integration into the hospital information system a complex and non-standard task. The rapid spread in availability and adoption of high-speed 802.11 wireless systems in hospitals offers a realistic connectivity solution for mobile medical devices. Inspite of this, the 802.11 standard is still evolving, and current security methods designed for user-based products like PDAs and laptop computers are not ideal for unmanned mobile medical devices because they assume the availability of a human operator to authenticate a wireless session. In the absence of accepted standards, manufacturers have created practical and innovative solutions to support the collection of clinical data from mobile medical devices and the integration of that data with hospital information systems. This paper will explore the potential benefits of integrating mobile medical devices into the hospital information system, and describe the challenges in

  11. An update on mobile phones interference with medical devices.

    Science.gov (United States)

    Mahmoud Pashazadeh, Ali; Aghajani, Mahdi; Nabipour, Iraj; Assadi, Majid

    2013-10-01

    Mobile phones' electromagnetic interference with medical devices is an important issue for the medical safety of patients who are using life-supporting medical devices. This review mainly focuses on mobile phones' interference with implanted medical devices and with medical equipment located in critical areas of hospitals. A close look at the findings reveals that mobile phones may adversely affect the functioning of medical devices, and the specific effect and the degree of interference depend on the applied technology and the separation distance. According to the studies' findings and the authors' recommendations, besides mitigating interference, using mobile phones at a reasonable distance from medical devices and developing technology standards can lead to their effective use in hospital communication systems.

  12. An update on mobile phones interference with medical devices

    International Nuclear Information System (INIS)

    Pashazadeh, A. M.; Aghajani, M.; Nabipour, I.; Assadi, M.

    2013-01-01

    Mobile phones' electromagnetic interference with medical devices is an important issue for the medical safety of patients who are using life-supporting medical devices. This review mainly focuses on mobile phones' interference with implanted medical devices and with medical equipment located in critical areas of hospitals. A close look at the findings reveals that mobile phones may adversely affect the functioning of medical devices, and the specific effect and the degree of interference depend on the applied technology and the separation distance. According to the studies' findings and the authors' recommendations, besides mitigating interference, using mobile phones at a reasonable distance from medical devices and developing technology standards can lead to their effective use in hospital communication systems. (authors)

  13. 78 FR 68853 - International Medical Device Regulators Forum; Medical Device Single Audit Program International...

    Science.gov (United States)

    2013-11-15

    ... its inaugural meeting in Singapore in 2012, identified a Work Group (WG) to develop specific documents... Assessment Method for the Recognition and Monitoring of Medical Device Auditing Organizations;'' and IMDRF...

  14. Class 1 devices case studies in medical devices design

    CERN Document Server

    Ogrodnik, Peter J

    2014-01-01

    The Case Studies in Medical Devices Design series consists of practical, applied case studies relating to medical device design in industry. These titles complement Ogrodnik's Medical Device Design and will assist engineers with applying the theory in practice. The case studies presented directly relate to Class I, Class IIa, Class IIb and Class III medical devices. Designers and companies who wish to extend their knowledge in a specific discipline related to their respective class of operation will find any or all of these titles a great addition to their library. Class 1 Devices is a companion text to Medical Devices Design: Innovation from Concept to Market. The intention of this book, and its sister books in the series, is to support the concepts presented in Medical Devices Design through case studies. In the context of this book the case studies consider Class I (EU) and 510(k) exempt (FDA) . This book covers classifications, the conceptual and embodiment phase, plus design from idea to PDS. These title...

  15. 76 FR 7220 - Medical Device Innovation Initiative; Request for Comments

    Science.gov (United States)

    2011-02-09

    ... medical device innovation. 6. Other actions CDRH should take to facilitate the development, assessment...] Medical Device Innovation Initiative; Request for Comments AGENCY: Food and Drug Administration, HHS... availability of a document for public comment entitled ``Medical Device Innovation Initiative'' (the report...

  16. Prospects of radiation sterilization of medical devices

    International Nuclear Information System (INIS)

    Hosobuchi, Kazunari

    1992-01-01

    Since radiation sterilization was first introduced in the United States in 1956 in the field of disposable medical devices, it has become an indispensable technique for sterilization because of the following reasons: (1) introduction into dialyzers, (2) introduction in medical device makers, (3) development of disposable medical devices associated with developing both high molecular chemistry and cool sterilization, (4) rationality of sterilization process, and (5) problems of sterilization with ethylene oxide gas. To promote the further development of radiation sterilization, the following items are considered necessary: (1) an increase in the number of facilities for radiation sterilization, (2) recommendation of the international standardization of sterilization method, (3) decrease in radiation doses associated with sterilization, (4) development of electron accelerators and bremsstrahlung equipments for radiation sources, and (5) simplification of sterilization process management. Factors precluding the development of radiation sterilization are: (1) development of other methods than radiation sterilization, (2) development of technique for sterile products, (3) high facility cost, (4) high irradiation cost, (5) benefits and limits of sterilization markets, and (6) influences of materials. (N.K.)

  17. 78 FR 68459 - Medical Device Development Tools; Draft Guidance for Industry, Tool Developers, and Food and Drug...

    Science.gov (United States)

    2013-11-14

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-D-1279] Medical Device Development Tools; Draft Guidance for Industry, Tool Developers, and Food and Drug Administration Staff; Availability AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food...

  18. Case outsourcing medical device reprocessing.

    Science.gov (United States)

    Haley, Deborah

    2004-04-01

    IN THE INTEREST OF SAVING MONEY, many hospitals are considering extending the life of some single-use medical devices by using medical device reprocessing programs. FACILITIES OFTEN LACK the resources required to meet the US Food and Drug Administration's tough quality assurance standards. BY OUTSOURCING, hospitals can reap the benefits of medical device reprocessing without assuming additional staffing and compliance burdens. OUTSOURCING enables hospitals to implement a medical device reprocessing program quickly, with no capital investment and minimal effort.

  19. Human Factors and Medical Devices

    International Nuclear Information System (INIS)

    Dick Sawyer

    1998-01-01

    Medical device hardware- and software-driven user interfaces should be designed to minimize the likelihood of use-related errors and their consequences. The role of design-induced errors in medical device incidents is attracting widespread attention. The U.S. Food and Drug Administration (FDA) is fully cognizant that human factors engineering is critical to the design of safe medical devices, and user interface design is receiving substantial attention by the agency. Companies are paying more attention to the impact of device design, including user instructions, upon the performance of those health professionals and lay users who operate medical devices. Concurrently, the FDA is monitoring human factors issues in its site inspections, premarket device approvals, and postmarket incident evaluations. Overall, the outlook for improved designs and safer device operation is bright

  20. The potential of medical device industry in technological and economical context.

    Science.gov (United States)

    Maresova, Petra; Penhaker, Marek; Selamat, Ali; Kuca, Kamil

    2015-01-01

    The high quality of public health improves not only healthy life expectancy, but also the productivity of labor. The most important part of the health care sector is the medical technology industry. The aim of this study is to analyze the current situation in the medical device industry in Europe, its potential strengths and weaknesses in the context of topical economic and demographic development. The contribution specifies an analysis of the economic state of the medical device industry in the context of demographic development of European Union's macroeconomic indicators and views of experts in the field of medical device development, concerning the opportunities for entities involved in the medical device market. There is fierce competition on the European market. The innovative activity is stable and well regulated by responsible authorities. Worldwide, the medical device market is expected to grow.

  1. Power Approaches for Implantable Medical Devices

    Directory of Open Access Journals (Sweden)

    Achraf Ben Amar

    2015-11-01

    Full Text Available Implantable medical devices have been implemented to provide treatment and to assess in vivo physiological information in humans as well as animal models for medical diagnosis and prognosis, therapeutic applications and biological science studies. The advances of micro/nanotechnology dovetailed with novel biomaterials have further enhanced biocompatibility, sensitivity, longevity and reliability in newly-emerged low-cost and compact devices. Close-loop systems with both sensing and treatment functions have also been developed to provide point-of-care and personalized medicine. Nevertheless, one of the remaining challenges is whether power can be supplied sufficiently and continuously for the operation of the entire system. This issue is becoming more and more critical to the increasing need of power for wireless communication in implanted devices towards the future healthcare infrastructure, namely mobile health (m-Health. In this review paper, methodologies to transfer and harvest energy in implantable medical devices are introduced and discussed to highlight the uses and significances of various potential power sources.

  2. [Medical Devices Law for pain therapists].

    Science.gov (United States)

    Regner, M; Sabatowski, R

    2016-08-01

    Medical Devices Law is a relatively new legal system, which has replaced the Medical Devices Regulations still well-known in Germany. German Medical Devices Law is based on European directives, which are, in turn, incorporated into national law by the Medical Devices Act. The Medical Devices Act is a framework law and covers a number of regulations that address specific topics within Medical Devices Law. In turn, in individual regulations, reference is made to guidelines, recommendations, etc. from other sources that provide detailed technical information on specific topics. Medical Devices Law is a very complex legal system, which needs to be permanently observed due to constant updating and adjustment. In the current article, the design and the structure of the system will be described, but special emphasis will be laid on important problem areas that need to be considered when applying and operating medical products, in this case by pain therapists in particular.

  3. Team-Based Development of Medical Devices: An Engineering–Business Collaborative

    Science.gov (United States)

    Eberhardt, Alan W.; Johnson, Ophelia L.; Kirkland, William B.; Dobbs, Joel H.; Moradi, Lee G.

    2016-01-01

    There is a global shift in the teaching methodology of science and engineering toward multidisciplinary, team-based processes. To meet the demands of an evolving technical industry and lead the way in engineering education, innovative curricula are essential. This paper describes the development of multidisciplinary, team-based learning environments in undergraduate and graduate engineering curricula focused on medical device design. In these programs, students actively collaborate with clinicians, professional engineers, business professionals, and their peers to develop innovative solutions to real-world problems. In the undergraduate senior capstone courses, teams of biomedical engineering (BME) and business students have produced and delivered numerous functional prototypes to satisfied clients. Pursuit of commercialization of devices has led to intellectual property (IP) disclosures and patents. Assessments have indicated high levels of success in attainment of student learning outcomes and student satisfaction with their undergraduate design experience. To advance these projects toward commercialization and further promote innovative team-based learning, a Master of Engineering (MEng) in Design and Commercialization was recently launched. The MEng facilitates teams of graduate students in engineering, life sciences, and business who engage in innovation-commercialization (IC) projects and coursework that take innovative ideas through research and development (R&D) to create marketable devices. The activities are structured with students working together as a “virtual company,” with targeted outcomes of commercialization (license agreements and new start-ups), competitive job placement, and/or career advancement. PMID:26902869

  4. Team-Based Development of Medical Devices: An Engineering-Business Collaborative.

    Science.gov (United States)

    Eberhardt, Alan W; Johnson, Ophelia L; Kirkland, William B; Dobbs, Joel H; Moradi, Lee G

    2016-07-01

    There is a global shift in the teaching methodology of science and engineering toward multidisciplinary, team-based processes. To meet the demands of an evolving technical industry and lead the way in engineering education, innovative curricula are essential. This paper describes the development of multidisciplinary, team-based learning environments in undergraduate and graduate engineering curricula focused on medical device design. In these programs, students actively collaborate with clinicians, professional engineers, business professionals, and their peers to develop innovative solutions to real-world problems. In the undergraduate senior capstone courses, teams of biomedical engineering (BME) and business students have produced and delivered numerous functional prototypes to satisfied clients. Pursuit of commercialization of devices has led to intellectual property (IP) disclosures and patents. Assessments have indicated high levels of success in attainment of student learning outcomes and student satisfaction with their undergraduate design experience. To advance these projects toward commercialization and further promote innovative team-based learning, a Master of Engineering (MEng) in Design and Commercialization was recently launched. The MEng facilitates teams of graduate students in engineering, life sciences, and business who engage in innovation-commercialization (IC) projects and coursework that take innovative ideas through research and development (R&D) to create marketable devices. The activities are structured with students working together as a "virtual company," with targeted outcomes of commercialization (license agreements and new start-ups), competitive job placement, and/or career advancement.

  5. 21 CFR 892.2040 - Medical image hardcopy device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical image hardcopy device. 892.2040 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2040 Medical image hardcopy device. (a) Identification. A medical image hardcopy device is a device that produces a visible printed record of a medical...

  6. [Consideration of Mobile Medical Device Regulation].

    Science.gov (United States)

    Peng, Liang; Yang, Pengfei; He, Weigang

    2015-07-01

    The regulation of mobile medical devices is one of the hot topics in the industry now. The definition, regulation scope and requirements, potential risks of mobile medical devices were analyzed and discussed based on mobile computing techniques and the FDA guidance of mobile medical applications. The regulation work of mobile medical devices in China needs to adopt the risk-based method.

  7. Assurance Cases for Medical Devices

    Science.gov (United States)

    2011-04-28

    the patient, and the hospital setting. Some pumps allow the patient to control part of the injection process (e.g. to inject more painkiller ...overdose, incorrect therapy, etc.   Design and development decisions that bear on safety and effectiveness http://www.fda.gov/MedicalDevices

  8. Risk evaluation of medical and industrial radiation devices

    International Nuclear Information System (INIS)

    Jones, E.D.; Cunningham, R.E.; Rathbun, P.A.

    1994-03-01

    In 1991, the NRC, Division of Industrial and Medical Nuclear Safety, began a program to evaluate the use of probabilistic risk assessment (PRA) in regulating medical devices. This program represents an initial step in an overall plant to evaluate the use of PRA in regulating the use of nuclear by-product materials. The NRC envisioned that the use of risk analysis techniques could assist staff in ensuring that the regulatory approach was standardized, understandable, and effective. Traditional methods of assessing risk in nuclear power plants may be inappropriate to use in assessing the use of by-product devices. The approaches used in assessing nuclear reactor risks are equipment-oriented. Secondary attention is paid to the human component, for the most part after critical system failure events have been identified. This paper describes the risk methodology developed by Lawrence Livermore National Laboratory (LLNL), initially intended to assess risks associated with the use of the Gamma Knife, a gamma stereotactic radiosurgical device. For relatively new medical devices such as the Gamma Knife, the challenge is to perform a risk analysis with very little quantitative data but with an important human factor component. The method described below provides a basic approach for identifying the most likely risk contributors and evaluating their relative importance. The risk analysis approach developed for the Gamma Knife and described in this paper should be applicable to a broader class of devices in which the human interaction with the device is a prominent factor. In this sense, the method could be a prototypical model of nuclear medical or industrial device risk analysis

  9. Regulatory affairs for biomaterials and medical devices

    CERN Document Server

    Amato, Stephen F; Amato, B

    2015-01-01

    All biomaterials and medical devices are subject to a long list of regulatory practises and policies which must be adhered to in order to receive clearance. This book provides readers with information on the systems in place in the USA and the rest of the world. Chapters focus on a series of procedures and policies including topics such as commercialization, clinical development, general good practise manufacturing and post market surveillance.Addresses global regulations and regulatory issues surrounding biomaterials and medical devicesEspecially useful for smaller co

  10. Promoting interdisciplinary project-based learning to build the skill sets for research and development of medical devices in academia.

    Science.gov (United States)

    Krishnan, Shankar

    2013-01-01

    The worldwide need for rapid expansion and diversification of medical devices and the corresponding requirements in industry pose arduous challenges for educators to train undergraduate biomedical engineering (BME) students. Preparing BME students for working in the research and development (R&D) in medical device industry is not easily accomplished by adopting traditional pedagogical methods. Even with the inclusion of the design and development elements in capstone projects, medical device industry may be still experience a gap in fulfilling their needs in R&D. This paper proposes a new model based on interdisciplinary project-based learning (IDPBL) to address the requirements of building the necessary skill sets in academia for carrying out R&D in medical device industry. The proposed model incorporates IDPBL modules distributed in a stepwise fashion through the four years of a typical BME program. The proposed model involves buy-in and collaboration from faculty as well as students. The implementation of the proposed design in an undergraduate BME program is still in process. However, a variant of the proposed IDPBL method has been attempted at a limited scale at the postgraduate level and has shown some success. Extrapolating the previous results, the adoption of the IDPBL to BME training seems to suggest promising outcomes. Despite numerous implementation challenges, with continued efforts, the proposed IDPBL will be valuable n academia for skill sets building for medical device R&D.

  11. Handheld Diagnostic Device Delivers Quick Medical Readings

    Science.gov (United States)

    2014-01-01

    To monitor astronauts' health remotely, Glenn Research Center awarded SBIR funding to Cambridge, Massachusetts-based DNA Medical Institute, which developed a device capable of analyzing blood cell counts and a variety of medical biomarkers. The technology will prove especially useful in rural areas without easy access to labs.

  12. Medical device risk management and its economic impact

    Directory of Open Access Journals (Sweden)

    Katerina Krsteva Jakimovska

    2013-10-01

    Full Text Available The importance of medical devices in everyday users/patients lives is imensse. This is the reason why emphasis must be put on safety during their use. Satisfactory safety level can be achived by implementation of quality and risk management standards. Medical device manufacturers must learn to deal with the potential risks by using theoretical and practical examples and measures in order to protect their users/patients and themselves from suffering huge losses arising from adverse events or recall of their products. The best moment for implementation of risk management methods and analysis begins from the device design and development through manufacturing, sales and distribution. These way medical device manufacturers will succseed in protecting their users/patients from serious adverse events and at the same time protect their brand and society status, while minimizing economic losses.

  13. International Standards for Radiation Sterilization of Medical Devices

    International Nuclear Information System (INIS)

    Miller, A.

    2007-01-01

    For a terminally sterilized medical device to be designated '' STERILE '', probability of finding the viable micro-organisms in the device shall be equal to or less than 1 x 10 -6 (EN 556-1:2001: Sterilization of medical devices - Requirements for medical devices to be designated '' STERILE '' - Part 1: Requirements for terminally sterilized medical devices). Author presents the main legal aspects of the international standards for radiation sterilization of medical devices

  14. The potential of medical device industry in technological and economical context

    Directory of Open Access Journals (Sweden)

    Maresova P

    2015-10-01

    Full Text Available Petra Maresova,1 Marek Penhaker,1,2 Ali Selamat,1,3 Kamil Kuca1,41Faculty of Informatics and Management, University of Hradec Králové, Hradec Králové, Czech Republic; 2Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, Technical University of Ostrava, Poruba, Czech Republic; 3Faculty of Computing, Universiti Teknologi Malaysia, Johor Bahru, Johor, Malaysia; 4Center for Biomedical Research, University Hospital Hradec Králové, Hradec Králové, Czech RepublicAbstract: The high quality of public health improves not only healthy life expectancy, but also the productivity of labor. The most important part of the health care sector is the medical technology industry. The aim of this study is to analyze the current situation in the medical device industry in Europe, its potential strengths and weaknesses in the context of topical economic and demographic development. The contribution specifies an analysis of the economic state of the medical device industry in the context of demographic development of European Union’s macroeconomic indicators and views of experts in the field of medical device development, concerning the opportunities for entities involved in the medical device market. There is fierce competition on the European market. The innovative activity is stable and well regulated by responsible authorities. Worldwide, the medical device market is expected to grow.Keywords: technology context, medical device, Europe, expenditure, review

  15. The Development of 1Balance: A Connected Medical Device for Measuring Human Balance

    Directory of Open Access Journals (Sweden)

    Heikki Sjöman

    2018-05-01

    Full Text Available Prototyping (iterative loops of design–build–test is a proven method of efficiently developing new products. Developing products not only quickly, but that are also fit for purpose, implies engaging the end users and iterating the technology at hand. However, there is currently little research on how engineering design can approach developing connected devices. The purpose of this paper is to distinguish and discuss design approaches that are suitable for connected devices. Internet of Things devices consist of both the physical products themselves and the data that is coming out of the products, which we define as the external and internal data, respectively. They both can be prototyped separately, but since the data acquired can influence the design of the device and vice versa, we propose to link these two together in the product development process. This issue becomes more apparent when designing networks of sensors, e.g., for complex artificial intelligence (AI databases. We explain the principle by describing the development of 1Balance through six different prototypes for human balance measurement. Technologically quantifying balance is an underused approach for objectively evaluating the state of a human’s performance. The authors have developed a mobile application for monitoring balance as a physiological signal (amount of sway via a compact wireless inertial measurement unit (IMU sensor strapped to the body of the subject for the duration of the measurement. We describe the design process for developing this connected medical device, as well as how the acquired data was used to improve the design of the product. In conclusion, we propose conceptually connecting the external and internal data prototyping loops.

  16. Early assessment of medical devices in development for company decision making : An exploration of best practices

    NARCIS (Netherlands)

    Markiewicz, Katarzyna; Van Til, Janine; IJzerman, Maarten

    2017-01-01

    To improve successful development and clinical use of medical technologies, it is suggested that manufacturers should start collecting evidence on devices effectiveness and eficiency early in their development. The aim of this study was to explore whether and how Dutch manufacturers perform an early

  17. Integrating health economics modeling in the product development cycle of medical devices: a Bayesian approach.

    Science.gov (United States)

    Vallejo-Torres, Laura; Steuten, Lotte M G; Buxton, Martin J; Girling, Alan J; Lilford, Richard J; Young, Terry

    2008-01-01

    Medical device companies are under growing pressure to provide health-economic evaluations of their products. Cost-effectiveness analyses are commonly undertaken as a one-off exercise at the late stage of development of new technologies; however, the benefits of an iterative use of economic evaluation during the development process of new products have been acknowledged in the literature. Furthermore, the use of Bayesian methods within health technology assessment has been shown to be of particular value in the dynamic framework of technology appraisal when new information becomes available in the life cycle of technologies. In this study, we set out a methodology to adapt these methods for their application to directly support investment decisions in a commercial setting from early stages of the development of new medical devices. Starting with relatively simple analysis from the very early development phase and proceeding to greater depth of analysis at later stages, a Bayesian approach facilitates the incorporation of all available evidence and would help companies to make better informed choices at each decision point.

  18. Wearable Devices in Medical Internet of Things: Scientific Research and Commercially Available Devices.

    Science.gov (United States)

    Haghi, Mostafa; Thurow, Kerstin; Stoll, Regina

    2017-01-01

    Wearable devices are currently at the heart of just about every discussion related to the Internet of Things. The requirement for self-health monitoring and preventive medicine is increasing due to the projected dramatic increase in the number of elderly people until 2020. Developed technologies are truly able to reduce the overall costs for prevention and monitoring. This is possible by constantly monitoring health indicators in various areas, and in particular, wearable devices are considered to carry this task out. These wearable devices and mobile apps now have been integrated with telemedicine and telehealth efficiently, to structure the medical Internet of Things. This paper reviews wearable health care devices both in scientific papers and commercial efforts. MIoT is demonstrated through a defined architecture design, including hardware and software dealing with wearable devices, sensors, smart phones, medical application, and medical station analyzers for further diagnosis and data storage. Wearables, with the help of improved technology have been developed greatly and are considered reliable tools for long-term health monitoring systems. These are applied in the observation of a large variety of health monitoring indicators in the environment, vital signs, and fitness. Wearable devices are now used for a wide range of healthcare observation. One of the most important elements essential in data collection is the sensor. During recent years with improvement in semiconductor technology, sensors have made investigation of a full range of parameters closer to realization.

  19. MEDIC: medical embedded device for individualized care.

    Science.gov (United States)

    Wu, Winston H; Bui, Alex A T; Batalin, Maxim A; Au, Lawrence K; Binney, Jonathan D; Kaiser, William J

    2008-02-01

    Presented work highlights the development and initial validation of a medical embedded device for individualized care (MEDIC), which is based on a novel software architecture, enabling sensor management and disease prediction capabilities, and commercially available microelectronic components, sensors and conventional personal digital assistant (PDA) (or a cell phone). In this paper, we present a general architecture for a wearable sensor system that can be customized to an individual patient's needs. This architecture is based on embedded artificial intelligence that permits autonomous operation, sensor management and inference, and may be applied to a general purpose wearable medical diagnostics. A prototype of the system has been developed based on a standard PDA and wireless sensor nodes equipped with commercially available Bluetooth radio components, permitting real-time streaming of high-bandwidth data from various physiological and contextual sensors. We also present the results of abnormal gait diagnosis using the complete system from our evaluation, and illustrate how the wearable system and its operation can be remotely configured and managed by either enterprise systems or medical personnel at centralized locations. By using commercially available hardware components and software architecture presented in this paper, the MEDIC system can be rapidly configured, providing medical researchers with broadband sensor data from remote patients and platform access to best adapt operation for diagnostic operation objectives.

  20. Body Implanted Medical Device Communications

    Science.gov (United States)

    Yazdandoost, Kamya Yekeh; Kohno, Ryuji

    The medical care day by day and more and more is associated with and reliant upon concepts and advances of electronics and electromagnetics. Numerous medical devices are implanted in the body for medical use. Tissue implanted devices are of great interest for wireless medical applications due to the promising of different clinical usage to promote a patient independence. It can be used in hospitals, health care facilities and home to transmit patient measurement data, such as pulse and respiration rates to a nearby receiver, permitting greater patient mobility and increased comfort. As this service permits remote monitoring of several patients simultaneously it could also potentially decrease health care costs. Advancement in radio frequency communications and miniaturization of bioelectronics are supporting medical implant applications. A central component of wireless implanted device is an antenna and there are several issues to consider when designing an in-body antenna, including power consumption, size, frequency, biocompatibility and the unique RF transmission challenges posed by the human body. The radiation characteristics of such devices are important in terms of both safety and performance. The implanted antenna and human body as a medium for wireless communication are discussed over Medical Implant Communications Service (MICS) band in the frequency range of 402-405MHz.

  1. Evaluating and Predicting Patient Safety for Medical Devices With Integral Information Technology

    Science.gov (United States)

    2005-01-01

    323 Evaluating and Predicting Patient Safety for Medical Devices with Integral Information Technology Jiajie Zhang, Vimla L. Patel, Todd R...errors are due to inappropriate designs for user interactions, rather than mechanical failures. Evaluating and predicting patient safety in medical ...the users on the identified trouble spots in the devices. We developed two methods for evaluating and predicting patient safety in medical devices

  2. Classification and evaluation of medical devices

    Directory of Open Access Journals (Sweden)

    Edina Vranić

    2003-05-01

    Full Text Available Medical devices and medical disposables contribute significantly to the quality and effectiveness of the health care system. It is necessary to commit scientifically sound regulatory environment that will provide consumers with the best medical care. This includes continued services to small manufacturers, readily available guidance on FDA requirements, predictable and reasonable response times on applications for marketing, and equitable enforcement. But in the public interest, this commitment to the industry must be coupled with a reciprocal commitment: that medical device firms will meet high standards in the design, manufacture, and evaluation of their products. The protections afforded our consumer, and the benefits provided the medical device industry, cannot be underestimated.

  3. Regulatory Science in Practice (Pharmaceuticals and Medical Devices Agency).

    Science.gov (United States)

    Hojo, Taisuke

    2017-01-01

    Review, safety, and relief services of the Pharmaceuticals and Medical Devices Agency are primarily focused on scientifically evaluating pharmaceuticals, medical devices, and cellular and tissue-based products referring to their quality, efficacy, and safety, which requires a variety of scientific knowledge and methods. Pharmaceutical regulation should be established based on the most advanced scientific expertise at all times. In order to evaluate products that use cutting-edge technology such as induced pluripotent stem cells and information and communication technology adequately, since fiscal year 2012 the Science Committee has been established as a platform to exchange opinions among members from top-ranking domestic and international academia and to enhance personnel exchanges through the Initiative to Facilitate Development of Innovative Drugs. In addition, the Regulatory Science Center will be established in 2018 to increase the integrity of our services for product reviews and safety measures. In particular, requiring electronic data submissions for clinical trial applications followed by an advanced approach to analysis should not only enhance the quality of reviews of individual products but should also support the development of pharmaceuticals and medical devices by providing pharmaceutical affairs consultations on research and development strategies with various guidelines based on new insights resulting from product-bridging data analysis. Moreover, a database including electronic health records with comprehensive medical information collected mainly from 10 cooperating medical institutions will be developed with the aim of developing safety measures in a more timely manner using methods of pharmacoepidemiological analysis.

  4. A user-centred approach to requirements elicitation in medical device development: a case study from an industry perspective.

    Science.gov (United States)

    Martin, Jennifer L; Clark, Daniel J; Morgan, Stephen P; Crowe, John A; Murphy, Elizabeth

    2012-01-01

    The healthcare industry is dependent upon the provision of well designed medical devices. To achieve this it is recommended that user-centred design should begin early, and continue throughout device development. This is a challenge, particularly for smaller companies who may lack the necessary expertise and knowledge. The aim of this study was to conduct a rigorous yet focused investigation into the user requirements for a new medical imaging device. Open-ended semi-structured interviews were conducted with potential clinical users of the device to investigate the clinical need for the device and the potential benefits for patients and clinical users. The study identified a number of new and significant clinical needs that suggested that the concept of the device should be fundamentally changed. The clinical and organisational priorities of the clinical users were identified, as well as a number of factors that would act as barriers to the safe and effective adoption of the device. The developers reported that this focused approach to early requirements elicitation would result in an improved product, reduce the time to market, and save the time and cost of producing and evaluating an inappropriate prototype. Copyright © 2011 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  5. Medical Device Integration Model Based on the Internet of Things

    Science.gov (United States)

    Hao, Aiyu; Wang, Ling

    2015-01-01

    At present, hospitals in our country have basically established the HIS system, which manages registration, treatment, and charge, among many others, of patients. During treatment, patients need to use medical devices repeatedly to acquire all sorts of inspection data. Currently, the output data of the medical devices are often manually input into information system, which is easy to get wrong or easy to cause mismatches between inspection reports and patients. For some small hospitals of which information construction is still relatively weak, the information generated by the devices is still presented in the form of paper reports. When doctors or patients want to have access to the data at a given time again, they can only look at the paper files. Data integration between medical devices has long been a difficult problem for the medical information system, because the data from medical devices are lack of mandatory unified global standards and have outstanding heterogeneity of devices. In order to protect their own interests, manufacturers use special protocols, etc., thus causing medical decices to still be the "lonely island" of hospital information system. Besides, unfocused application of the data will lead to failure to achieve a reasonable distribution of medical resources. With the deepening of IT construction in hospitals, medical information systems will be bound to develop towards mobile applications, intelligent analysis, and interconnection and interworking, on the premise that there is an effective medical device integration (MDI) technology. To this end, this paper presents a MDI model based on the Internet of Things (IoT). Through abstract classification, this model is able to extract the common characteristics of the devices, resolve the heterogeneous differences between them, and employ a unified protocol to integrate data between devices. And by the IoT technology, it realizes interconnection network of devices and conducts associate matching

  6. Use-related risk analysis for medical devices based on improved FMEA.

    Science.gov (United States)

    Liu, Long; Shuai, Ma; Wang, Zhu; Li, Ping

    2012-01-01

    In order to effectively analyze and control use-related risk of medical devices, quantitative methodologies must be applied. Failure Mode and Effects Analysis (FMEA) is a proactive technique for error detection and risk reduction. In this article, an improved FMEA based on Fuzzy Mathematics and Grey Relational Theory is developed to better carry out user-related risk analysis for medical devices. As an example, the analysis process using this improved FMEA method for a certain medical device (C-arm X-ray machine) is described.

  7. MedMon: securing medical devices through wireless monitoring and anomaly detection.

    Science.gov (United States)

    Zhang, Meng; Raghunathan, Anand; Jha, Niraj K

    2013-12-01

    Rapid advances in personal healthcare systems based on implantable and wearable medical devices promise to greatly improve the quality of diagnosis and treatment for a range of medical conditions. However, the increasing programmability and wireless connectivity of medical devices also open up opportunities for malicious attackers. Unfortunately, implantable/wearable medical devices come with extreme size and power constraints, and unique usage models, making it infeasible to simply borrow conventional security solutions such as cryptography. We propose a general framework for securing medical devices based on wireless channel monitoring and anomaly detection. Our proposal is based on a medical security monitor (MedMon) that snoops on all the radio-frequency wireless communications to/from medical devices and uses multi-layered anomaly detection to identify potentially malicious transactions. Upon detection of a malicious transaction, MedMon takes appropriate response actions, which could range from passive (notifying the user) to active (jamming the packets so that they do not reach the medical device). A key benefit of MedMon is that it is applicable to existing medical devices that are in use by patients, with no hardware or software modifications to them. Consequently, it also leads to zero power overheads on these devices. We demonstrate the feasibility of our proposal by developing a prototype implementation for an insulin delivery system using off-the-shelf components (USRP software-defined radio). We evaluate its effectiveness under several attack scenarios. Our results show that MedMon can detect virtually all naive attacks and a large fraction of more sophisticated attacks, suggesting that it is an effective approach to enhancing the security of medical devices.

  8. Medical device market in China.

    Science.gov (United States)

    Boyer, Philip; Morshed, Bashir I; Mussivand, Tofy

    2015-06-01

    With China's growing old-age population and economic presence on the international stage, it has become important to evaluate its domestic and foreign market contribution to medical devices. Medical devices are instruments or apparatuses used in the prevention, rehabilitation, treatment, or knowledge generation with respect to disease or other abnormal conditions. This article provides information drawn from recent publications to describe the current state of the Chinese domestic market for medical devices and to define opportunities for foreign investment potential therein. Recent healthcare reforms implemented to meet rising demand due to an aging and migrating population are having a positive effect on market growth-a global market with a projected growth of 15% per year over the next decade. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  9. Telemetry and Telestimulation via Implanted Devices Necessary in Long-Term Experiments Using Conscious Untethered Animals for the Development of New Medical Treatments

    Science.gov (United States)

    Sugimachi, Masaru; Kawada, Toru; Uemura, Kazunori

    Effective countermeasures against explosive increase in healthcare expenditures are urgently needed. A paradigm shift in healthcare is called for, and academics and governments worldwide are working hard on the application of information and communication technologies (ICT) as a feasible and effective measure for reducing medical cost. The more prevalent the disease and the easier disease outcome can be improved, the more efficient is medical ICT in reducing healthcare cost. Hypertension and diabetes mellitus are such examples. Chronic heart failure is another disease in which patients may benefit from ICT-based medical practice. It is conceivable that daily monitoring of hemodynamics together with appropriate treatments may obviate the expensive hospitalization. ICT potentially permit continuous monitoring with wearable or implantable medical devices. ICT may also help accelerate the development of new therapeutic devices. Traditionally effectiveness of treatments is sequentially examined by sacrificing a number of animals at a given time point. These inefficient and inaccurate methods can be replaced by applying ICT to the devices used in chronic animal experiments. These devices allow researchers to obtain biosignals and images from live animals without killing them. They include implantable telemetric devices, implantable telestimulation devices, and imaging devices. Implanted rather than wired monitoring and stimulation devices permit experiments to be conducted under even more physiological conditions, i.e., untethered, free-moving states. Wireless communication and ICT are indispensible technologies for the development of such telemetric and telestimulation devices.

  10. Laser direct writing of micro- and nano-scale medical devices

    Science.gov (United States)

    Gittard, Shaun D; Narayan, Roger J

    2010-01-01

    Laser-based direct writing of materials has undergone significant development in recent years. The ability to modify a variety of materials at small length scales and using short production times provides laser direct writing with unique capabilities for fabrication of medical devices. In many laser-based rapid prototyping methods, microscale and submicroscale structuring of materials is controlled by computer-generated models. Various laser-based direct write methods, including selective laser sintering/melting, laser machining, matrix-assisted pulsed-laser evaporation direct write, stereolithography and two-photon polymerization, are described. Their use in fabrication of microstructured and nanostructured medical devices is discussed. Laser direct writing may be used for processing a wide variety of advanced medical devices, including patient-specific prostheses, drug delivery devices, biosensors, stents and tissue-engineering scaffolds. PMID:20420557

  11. Health Care: Reprocessed Medical Single-Use Devices in DoD

    National Research Council Canada - National Science Library

    2002-01-01

    ... for decontamination and resterilization. The emergence of new materials and sterilization methods, and the increasing costs of health care, resulted in the development of medical single-use devices and the practice of reprocessing the devices...

  12. Rapid Globalization of Medical Device Clinical Development Programs in Japan - The Case of Drug-Eluting Stents.

    Science.gov (United States)

    Murakami, Madoka; Suzuki, Yuka; Tominaga, Toshiyoshi

    2018-02-23

    Delays in the introduction to the Japanese market of drug-eluting stents (DES) developed overseas (i.e., "device lag") decreased sharply between 2004 and 2012. The reduction accompanied a shift in clinical development from a succession pattern (initial product development and approval overseas followed by eventual entrance into the Japanese market) to parallel development (employing multiregional clinical trials (MRCTs)). Although resource-intensive in the short-term, MRCTs are proving to be an effective tool in simultaneous global product development. Creative study designs and the absence of significant ethnic differences in Japanese subjects regarding DES safety and efficacy and the pharmacokinetic behavior of their coating drugs propel this process. More general factors such as medical need and industry incentivization also encourage this shift. Physicians' preference for DES over other percutaneous coronary interventions, the expanding global DES market, and streamlined development and approval prospects each motivate industry to continue investing in DES product development. The efforts of various stakeholders were also integral to overcoming practical obstacles, and contributions by 'Harmonization by Doing' and a premarket collaboration initiative between the USA and Japan were particularly effective. Today, USA/Japan regulatory cooperation is routine, and Japan is now integrated into global medical device development. MRCTs including Japanese subjects, sites, and investigators are now commonplace.

  13. How can cardiothoracic and vascular medical devices stay in the market?

    Science.gov (United States)

    Wong, Kathie A; Hodgson, Luke; Garas, George; Malietzis, George; Markar, Sheraz; Rao, Christopher; von Segesser, Ludwig K; Athanasiou, Thanos

    2016-12-01

    Surgeons, as the consumers, must engage in commercial activity regarding medical devices since it directly has impacts on surgical practice and patient outcomes. Unique features defy traditional economic convention in this specific market partly because consumers do not usually pay directly. Greater involvement with commercial activity means better post-market surveillance of medical devices which leads to improved patient safety. The medical device industry has exhibited astonishing levels of growth and profitability reaching $398 billion on a global scale with new product development focusing on unmet clinical need. The industry has rapidly emerged within the context of an ageing population and a global surge in healthcare spending. But the market remains fragmented. The split of consumer, purchaser and payer leads to clinical need driving demand for new product development. This demand contributes to potentially large profit margins mainly contained by regulatory burden and liability issues. Demographic trends, prevalence of diseases and a huge capacity to absorb technology have sustained near unparalleled growth. To stay in the market, incremental development over the short term is essentially aided by responsiveness to demand. Disruptive product development is now more likely to come from multinational companies, in an increasingly expensive, regulated industry. Understanding healthcare organization can help explain the highly complex process of diffusion of innovations in healthcare that include medical devices. The time has come for surgeons to become actively involved with all aspects of the medical device life cycle including commercial activity and post-market surveillance. This is vital for improving patient care and ensuring patient safety. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  14. Medical devices and human engineering

    CERN Document Server

    Bronzino, Joseph D

    2014-01-01

    Known as the bible of biomedical engineering, The Biomedical Engineering Handbook, Fourth Edition, sets the standard against which all other references of this nature are measured. As such, it has served as a major resource for both skilled professionals and novices to biomedical engineering.Medical Devices and Human Engineering, the second volume of the handbook, presents material from respected scientists with diverse backgrounds in biomedical sensors, medical instrumentation and devices, human performance engineering, rehabilitation engineering, and clinical engineering.More than three doze

  15. Medical device reliability and associated areas

    National Research Council Canada - National Science Library

    Dhillon, Balbir S

    2000-01-01

    .... Although the history of reliability engineering can be traced back to World War II, the application of reliability engineering concepts to medical devices is a fairly recent idea that goes back to the latter part of the 1960s when many publications on medical device reliability emerged. Today, a large number of books on general reliability have been...

  16. Sterilization and reprocessing of materials and medical devices--reusability.

    Science.gov (United States)

    Jayabalan, M

    1995-07-01

    Problems associated with reprocessing of disposable medical devices such as hemodialysers with resterilization for reuse and changes in material properties with resterilization of polymeric (PVC, polypropylene, polyester, polycarbonate) materials intended for development of disposable devices are reviewed. Reprocessing of hospital supplies, polystyrene microtiter plate and angiographic catheter for reuse is also discussed.

  17. Development of bacterially resistant polyurethane for coating medical devices

    International Nuclear Information System (INIS)

    Roohpour, Nima; Moshaverinia, Alireza; Wasikiewicz, Jaroslaw M; Paul, Deepen; Vadgama, Pankaj; Wilks, Mark; Millar, Michael

    2012-01-01

    Polyurethanes have been widely used in medicine for coating and packaging implantable and other medical devices. Polyether-urethanes, in particular, have superior mechanical properties and are biocompatible, but in common with other medical materials they are susceptible to microbial film formation. In this study, polyether-urethane was end-capped with silver lactate and silver sulfadiazine functional groups to produce a bacterially resistant polymer without sacrificing the useful mechanical properties of the polyether-polyurethane. The silver ions were covalently incorporated into the polymer during chain extension of the prepolymer. The functionalized polymers were structurally characterized by light scattering, electron microscopy, NMR, FTIR and Raman spectroscopy. Mechanical properties, hydrophilicity, in vitro stability and antibacterial action of polymers were also investigated. Results indicate that both silver salts were successfully incorporated into the polymer structure without significant effect on mechanical properties, whilst conferring acceptable bacterial resistance.

  18. Model-based engineering for medical-device software.

    Science.gov (United States)

    Ray, Arnab; Jetley, Raoul; Jones, Paul L; Zhang, Yi

    2010-01-01

    This paper demonstrates the benefits of adopting model-based design techniques for engineering medical device software. By using a patient-controlled analgesic (PCA) infusion pump as a candidate medical device, the authors show how using models to capture design information allows for i) fast and efficient construction of executable device prototypes ii) creation of a standard, reusable baseline software architecture for a particular device family, iii) formal verification of the design against safety requirements, and iv) creation of a safety framework that reduces verification costs for future versions of the device software. 1.

  19. [Ethic review on clinical experiments of medical devices in medical institutions].

    Science.gov (United States)

    Shuai, Wanjun; Chao, Yong; Wang, Ning; Xu, Shining

    2011-07-01

    Clinical experiments are always used to evaluate the safety and validity of medical devices. The experiments have two types of clinical trying and testing. Ethic review must be done by the ethics committee of the medical department with the qualification of clinical research, and the approval must be made before the experiments. In order to ensure the safety and validity of clinical experiments of medical devices in medical institutions, the contents, process and approval criterions of the ethic review were analyzed and discussed.

  20. Biomaterials and medical devices a perspective from an emerging country

    CERN Document Server

    Hermawan, Hendra

    2016-01-01

    This book presents an introduction to biomaterials with the focus on the current development and future direction of biomaterials and medical devices research and development in Indonesia. It is the first biomaterials book written by selected academic and clinical experts experts on biomaterials and medical devices from various institutions and industries in Indonesia. It serves as a reference source for researchers starting new projects, for companies developing and marketing products and for governments setting new policies. Chapter one covers the fundamentals of biomaterials, types of biomaterials, their structures and properties and the relationship between them. Chapter two discusses unconventional processing of biomaterials including nano-hybrid organic-inorganic biomaterials. Chapter three addresses biocompatibility issues including in vitro cytotoxicity, genotoxicity, in vitro cell models, biocompatibility data and its related failure. Chapter four describes degradable biomaterial for medical implants...

  1. Best practices in early phase medical device development: Engineering, prototyping, and the beginnings of a quality management system.

    Science.gov (United States)

    Fearis, Kristy; Petrie, Aidan

    2017-03-01

    Kristy Fearis is the founder and president of KPConsulting. She has held various positions in the medical device and research industry. She has led programs for medical industry leaders Medtronic, Edward Lifesciences, and Kimberly-Clark Healthcare to develop and commercialize Class II and III devices. Although a true quality management systems specialist at heart, Kristy has a passion for effectively and efficiently applying quality systems principles to early stage development to maximize benefit while minimizing impact on resources and time to market. Kristy works with both precommercial and commercial companies to build and implement quality systems that are "right sized" and support both an effective business model and high product quality. Aidan Petrie is the cofounder and chief innovation officer of Ximedica. Aidan drives innovation in Ximedica's core markets of medical device development and consumer healthcare. With a focus on human-centered design, usability, technical innovation and industrial design, Aidan has helped bring hundreds of products to market. Ranging from simple drug compliance aids to wearable therapeutics, home monitoring products, and complex surgical systems, Aidan challenges his teams to rethink the role design plays in the success of each product. Covering topics around usability, sensor and wearable technology, and current trends in medical design and development, Aidan is a sought-after industry speaker and widely published author. In addition to his role at Ximedica, Aidan advises multiple startups in the healthcare space and has interests in a number of related companies. He sits on the Board of MassArt and teaches and lectures at the Rhode Island School of Design, Massachusetts Institute of Technology, the Harvard iLab, and others. Aidan holds an undergraduate degree from Central St Martins in product design/engineering and a Masters in industrial design from the Rhode Island School of Design. Copyright © 2016 Elsevier Inc. All

  2. Development of a Modular Research Platform to Create Medical Observational Studies for Mobile Devices.

    Science.gov (United States)

    Zens, Martin; Grotejohann, Birgit; Tassoni, Adrian; Duttenhoefer, Fabian; Südkamp, Norbert P; Niemeyer, Philipp

    2017-05-23

    Observational studies have proven to be a valuable resource in medical research, especially when performed on a large scale. Recently, mobile device-based observational studies have been discovered by an increasing number of researchers as a promising new source of information. However, the development and deployment of app-based studies is not trivial and requires profound programming skills. The aim of this project was to develop a modular online research platform that allows researchers to create medical studies for mobile devices without extensive programming skills. The platform approach for a modular research platform consists of three major components. A Web-based platform forms the researchers' main workplace. This platform communicates via a shared database with a platform independent mobile app. Furthermore, a separate Web-based login platform for physicians and other health care professionals is outlined and completes the concept. A prototype of the research platform has been developed and is currently in beta testing. Simple questionnaire studies can be created within minutes and published for testing purposes. Screenshots of an example study are provided, and the general working principle is displayed. In this project, we have created a basis for a novel research platform. The necessity and implications of a modular approach were displayed and an outline for future development given. International researchers are invited and encouraged to participate in this ongoing project. ©Martin Zens, Birgit Grotejohann, Adrian Tassoni, Fabian Duttenhoefer, Norbert P Südkamp, Philipp Niemeyer. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 23.05.2017.

  3. Scouting For Approval: Lessons on Medical Device Regulation in an Era of Crowdfunding from Scanadu's "Scout".

    Science.gov (United States)

    Smith, Colleen

    2015-01-01

    Internet crowdfunding, a new and increasingly popular method of raising capital to develop products and businesses, has recently come into conflict with the Food and Drug Administration's (FDA's) regulation of medical devices. This Article examines the issues that arise when companies pre-sell medical devices via crowdfunding campaigns before gaining FDA approval of the devices. Because Internet crowdfunding has only been in use for a few years, little has been written about it academically, particularly about its interaction with FDA regulations. The rising interest in crowdfunding, coupled with the downturn in investment in the American medical device industry, make this a salient issue that is ripe for FDA review. This Article uses the crowdfunding campaign Scanadu, a medical device company, conducted in 2013 to raise money to develop its in-home diagnostic device, the "Scout," as a starting point for this analysis. Because it is extremely costly to develop a device and obtain FDA approval, medical device companies should be able to utilize crowdfunding to raise the necessary capital. However, because of the possible dangers medical devices pose, FDA needs to review the risks created by allowing companies to crowdfund medical devices and should issue guidance to help companies comply with FDA regulations while still allowing them to take advantage of the benefits of crowdfunding. This guidance should ensure the continued commitment to consumer safety that is at the core of FDA regulation.

  4. Protecting computer-based medical devices: defending against viruses and other threats.

    Science.gov (United States)

    2005-07-01

    The increasing integration of computer hardware has exposed medical devices to greater risks than ever before. More and more devices rely on commercial off-the-shelf software and operating systems, which are vulnerable to the increasing proliferation of viruses and other malicious programs that target computers. Therefore, it is necessary for hospitals to take steps such as those outlined in this article to ensure that their computer-based devices are made safe and continue to remain safe in the future. Maintaining the security of medical devices requires planning, careful execution, and a commitment of resources. A team should be created to develop a process for surveying the security status of all computerized devices in the hospital and making sure that patches and other updates are applied as needed. These patches and updates should be approved by the medical system supplier before being implemented. The team should consider using virtual local area networks to isolate susceptible devices on the hospital's network. All security measures should be carefully documented, and the documentation should be kept up-to-date. Above all, care must be taken to ensure that medical device security involves a collaborative, supportive partnership between the hospital's information technology staff and biomedical engineering personnel.

  5. 78 FR 21129 - Orthopaedic and Rehabilitation Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2013-04-09

    ... radiofrequency band ranging between 13 megahertz to 27.12 megahertz and is intended for the treatment of medical...] Orthopaedic and Rehabilitation Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: Orthopaedic and Rehabilitation Devices Panel of the Medical Devices...

  6. Extended device profiles and testing procedures for the approval process of integrated medical devices using the IEEE 11073 communication standard.

    Science.gov (United States)

    Janß, Armin; Thorn, Johannes; Schmitz, Malte; Mildner, Alexander; Dell'Anna-Pudlik, Jasmin; Leucker, Martin; Radermacher, Klaus

    2018-02-23

    Nowadays, only closed and proprietary integrated operating room systems (IORS) from big manufacturers are available on the market. Hence, the interconnection of components from third-party vendors is only possible with increased time and costs. In the context of the German Federal Ministry of Education and Research (BMBF)-funded project OR.NET (2012-2016), the open integration of medical devices from different manufacturers was addressed. An integrated operating theater based on the open communication standard IEEE 11073 shall give clinical operators the opportunity to choose medical devices independently of the manufacturer. This approach would be advantageous especially for hospital operators and small- and medium-sized enterprises (SME) of medical devices. Actual standards and concepts regarding technical feasibility and the approval process do not cope with the requirements for a modular integration of medical devices in the operating room (OR), based on an open communication standard. Therefore, innovative approval strategies and corresponding certification and test procedures, which cover actual legal and normative standards, have to be developed in order to support the future risk management and the usability engineering process of open integrated medical devices in the OR. The use of standardized device and service profiles and a three-step testing procedure, including conformity, interoperability and integration tests are described in this paper and shall support the manufacturers to integrate their medical devices without disclosing the medical devices' risk analysis and related confidential expertise or proprietary information.

  7. Anti-malware software and medical devices.

    Science.gov (United States)

    2010-10-01

    Just as much as healthcare information systems, medical devices need protection against cybersecurity threats. Anti-malware software can help safeguard the devices in your facility-but it has limitations and even risks. Find out what steps you can take to manage anti-malware applications in your devices.

  8. Early-stage valuation of medical devices: the role of developmental uncertainty.

    Science.gov (United States)

    Girling, Alan; Young, Terry; Brown, Celia; Lilford, Richard

    2010-08-01

    At the concept stage, many uncertainties surround the commercial viability of a new medical device. These include the ultimate functionality of the device, the cost of producing it and whether, and at what price, it can be sold to a health-care provider (HCP). Simple assessments of value can be made by estimating such unknowns, but the levels of uncertainty may mean that their operational value for investment decisions is unclear. However, many decisions taken at the concept stage are reversible and will be reconsidered later before the product is brought to market. This flexibility can be exploited to enhance early-stage valuations. To develop a framework for valuing a new medical device at the concept stage that balances benefit to the HCP against commercial costs. This is done within a simplified stage-gated model of the development cycle for new products. The approach is intended to complement existing proposals for the evaluation of the commercial headroom available to new medical products. A model based on two decision gates can lead to lower bounds (underestimates) for product value that can serve to support a decision to develop the product. Quantifiable uncertainty that can be resolved before the device is brought to market will generally enhance early-stage valuations of the device, and this remains true even when some components of uncertainty cannot be fully described. Clinical trials and other evidence-gathering activities undertaken as part of the development process can contribute to early-stage estimates of value.

  9. MDR (Medical Device Reporting)

    Data.gov (United States)

    U.S. Department of Health & Human Services — This database allows you to search the CDRH's database information on medical devices which may have malfunctioned or caused a death or serious injury during the...

  10. 78 FR 68714 - Medical Devices; Ophthalmic Devices; Classification of the Scleral Plug

    Science.gov (United States)

    2013-11-15

    ... amendments), as ``preamendments devices.'' FDA classifies these devices after the Agency takes the following.... FDA-2012-N-1238] Medical Devices; Ophthalmic Devices; Classification of the Scleral Plug AGENCY: Food... scleral plugs in order to provide a reasonable assurance of safety and effectiveness of the device. The...

  11. Methodological considerations in observational comparative effectiveness research for implantable medical devices: an epidemiologic perspective.

    Science.gov (United States)

    Jalbert, Jessica J; Ritchey, Mary Elizabeth; Mi, Xiaojuan; Chen, Chih-Ying; Hammill, Bradley G; Curtis, Lesley H; Setoguchi, Soko

    2014-11-01

    Medical devices play a vital role in diagnosing, treating, and preventing diseases and are an integral part of the health-care system. Many devices, including implantable medical devices, enter the market through a regulatory pathway that was not designed to assure safety and effectiveness. Several recent studies and high-profile device recalls have demonstrated the need for well-designed, valid postmarketing studies of medical devices. Medical device epidemiology is a relatively new field compared with pharmacoepidemiology, which for decades has been developed to assess the safety and effectiveness of medications. Many methodological considerations in pharmacoepidemiology apply to medical device epidemiology. Fundamental differences in mechanisms of action and use and in how exposure data are captured mean that comparative effectiveness studies of medical devices often necessitate additional and different considerations. In this paper, we discuss some of the most salient issues encountered in conducting comparative effectiveness research on implantable devices. We discuss special methodological considerations regarding the use of data sources, exposure and outcome definitions, timing of exposure, and sources of bias. © The Author 2014. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  12. A Maturity Grid Assessment Tool for Environmentally Conscious Design in the Medical Device Industry

    DEFF Research Database (Denmark)

    Moultrie, James; Sutcliffe, Laura Francesca Rose; Maier, Anja

    2016-01-01

    . This intervention tool provides designers and product marketers with insights on how to improve the design of their medical devices and specifically allows consideration of the complex trade-offs between decisions that influence different life-cycle stages. Through the tool, actionable insight is created......The medical device industry is growing increasingly concerned about environmental impact of products. Whilst there are many tools aiming to support environmentally conscious design, they are typically complex to use, demand substantial data collection and are not tailored to the specific needs...... of the medical device sector. This paper reports on the development of a Maturity Grid to address this gap. This novel design tool was developed iteratively through application in five case studies. The tool captures principles of eco-design for medical devices in a simple form, designed to be used by a team...

  13. Research and development of metals for medical devices based on clinical needs

    Directory of Open Access Journals (Sweden)

    Takao Hanawa

    2012-01-01

    Full Text Available The current research and development of metallic materials used for medicine and dentistry is reviewed. First, the general properties required of metals used in medical devices are summarized, followed by the needs for the development of α + β type Ti alloys with large elongation and β type Ti alloys with a low Young's modulus. In addition, nickel-free Ni–Ti alloys and austenitic stainless steels are described. As new topics, we review metals that are bioabsorbable and compatible with magnetic resonance imaging. Surface treatment and modification techniques to improve biofunctions and biocompatibility are categorized, and the related problems are presented at the end of this review. The metal surface may be biofunctionalized by various techniques, such as dry and wet processes. These techniques make it possible to apply metals to scaffolds in tissue engineering.

  14. Use of mobile devices for medical imaging.

    Science.gov (United States)

    Hirschorn, David S; Choudhri, Asim F; Shih, George; Kim, Woojin

    2014-12-01

    Mobile devices have fundamentally changed personal computing, with many people forgoing the desktop and even laptop computer altogether in favor of a smaller, lighter, and cheaper device with a touch screen. Doctors and patients are beginning to expect medical images to be available on these devices for consultative viewing, if not actual diagnosis. However, this raises serious concerns with regard to the ability of existing mobile devices and networks to quickly and securely move these images. Medical images often come in large sets, which can bog down a network if not conveyed in an intelligent manner, and downloaded data on a mobile device are highly vulnerable to a breach of patient confidentiality should that device become lost or stolen. Some degree of regulation is needed to ensure that the software used to view these images allows all relevant medical information to be visible and manipulated in a clinically acceptable manner. There also needs to be a quality control mechanism to ensure that a device's display accurately conveys the image content without loss of contrast detail. Furthermore, not all mobile displays are appropriate for all types of images. The smaller displays of smart phones, for example, are not well suited for viewing entire chest radiographs, no matter how small and numerous the pixels of the display may be. All of these factors should be taken into account when deciding where, when, and how to use mobile devices for the display of medical images. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  15. 77 FR 72924 - Taxable Medical Devices

    Science.gov (United States)

    2012-12-07

    ... in hospitals, doctors offices and other medical institutions, such as x-ray machines, magnetic... the medical device context include sales to hospitals and other medical service providers. Although... of a taxable article to charity constitutes a taxable use under section 4218. However, the IRS and...

  16. Preventing medical device recalls

    CERN Document Server

    Raheja, Dev

    2014-01-01

    Introduction to Medical Device RequirementsIntroductionThe ChallengesSources of ErrorsUnderstanding the Science of Safety     Overview of FDA Quality System Regulation     Overview of Risk Management Standard ISO 14971     Overview of FDA Device Approval Process     Overview of Regulatory Requirements for Clinical TrialsSummaryReferencesPreventing Recalls during Specification WritingIntroductionConduct Requirements Analysis to Identify Missing RequirementsSpecifications for Safety, Durability, and

  17. 78 FR 26786 - Microbiology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2013-05-08

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-0001] Microbiology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and Drug...: Microbiology Devices Panel of the Medical Devices Advisory Committee. General Function of the Committee: To...

  18. 76 FR 48871 - Immunology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2011-08-09

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] Immunology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and Drug...: Immunology Devices Panel of the Medical Devices Advisory Committee. General Function of the Committee: To...

  19. Product-based Safety Certification for Medical Devices Embedded Software.

    Science.gov (United States)

    Neto, José Augusto; Figueiredo Damásio, Jemerson; Monthaler, Paul; Morais, Misael

    2015-01-01

    Worldwide medical device embedded software certification practices are currently focused on manufacturing best practices. In Brazil, the national regulatory agency does not hold a local certification process for software-intensive medical devices and admits international certification (e.g. FDA and CE) from local and international industry to operate in the Brazilian health care market. We present here a product-based certification process as a candidate process to support the Brazilian regulatory agency ANVISA in medical device software regulation. Center of Strategic Technology for Healthcare (NUTES) medical device embedded software certification is based on a solid safety quality model and has been tested with reasonable success against the Class I risk device Generic Infusion Pump (GIP).

  20. Integrated health outcomes research strategies in drug or medical device development, pre- and postmarketing: time for change.

    Science.gov (United States)

    Badía, Xavier; Guyver, Alice; Magaz, Sol; Bigorra, Juan

    2002-06-01

    The implementation of health outcomes research as a healthcare decision-making tool has expanded rapidly in the last decade. Drugs and medical devices are increasingly being required to demonstrate not only their efficacy and safety characteristics, but also their performance in at least three core dimensions of health outcomes research: clinical effectiveness, patient-reported outcomes and economic outcomes. However, the current integration of health outcomes research lacks coordination and communication and as a result, money and time is being spent on the generation of health outcomes research data which can be both insufficient and fail to satisfy the information demands of all the relevant stakeholders. In response to this, a new paradigm is evolving which involves the implementation of health outcomes research strategies that encompass the development, pre- and postmarketing stages of a drug or medical device.

  1. On the impact of medical device regulations on software architecture

    DEFF Research Database (Denmark)

    Hansen, Klaus Marius; Manikas, Konstantinos

    2016-01-01

    Compliance to regulations and regulatory approval are requirements for many medical device software systems. In this paper, we investigate the implications of medical device software regulations to the design of software systems. We do so by focusing on the American and European regulatory author...... of the device. Moreover, we review software modularity in the implementation of software medical device and propose a set of preliminary principles for architectural design of software medical device based on a set of constrains identified from the reviewed regulations....

  2. Medical Device Integrated Vital Signs Monitoring Application with Real-Time Clinical Decision Support.

    Science.gov (United States)

    Moqeem, Aasia; Baig, Mirza; Gholamhosseini, Hamid; Mirza, Farhaan; Lindén, Maria

    2018-01-01

    This research involves the design and development of a novel Android smartphone application for real-time vital signs monitoring and decision support. The proposed application integrates market available, wireless and Bluetooth connected medical devices for collecting vital signs. The medical device data collected by the app includes heart rate, oxygen saturation and electrocardiograph (ECG). The collated data is streamed/displayed on the smartphone in real-time. This application was designed by adopting six screens approach (6S) mobile development framework and focused on user-centered approach and considered clinicians-as-a-user. The clinical engagement, consultations, feedback and usability of the application in the everyday practices were considered critical from the initial phase of the design and development. Furthermore, the proposed application is capable to deliver rich clinical decision support in real-time using the integrated medical device data.

  3. [Industry regulation and its relationship to the rapid marketing of medical devices].

    Science.gov (United States)

    Matsuoka, Atsuko

    2012-01-01

    In the market of medical devices, non-Japanese products hold a large part even in Japan. To overcome this situation, the Japanese government has been announcing policies to encourage the medical devices industry, such as the 5-year strategy for medical innovation (June 6, 2012). The Division of Medical Devices has been contributing to rapid marketing of medical devices by working out the standards for approval review and accreditation of medical devices, guidances on evaluation of medical devices with emerging technology, and test methods for biological safety evaluation of medical devices, as a part of practice in the field of regulatory science. The recent outcomes are 822 standards of accreditation for Class II medical devices, 14 guidances on safety evaluation of medical devices with emerging technology, and the revised test methods for biological safety evaluation (MHLW Notification by Director, OMDE, Yakushokuki-hatsu 0301 No. 20 "Basic Principles of Biological Safety Evaluation Required for Application for Approval to Market Medical Devices").

  4. BioInnovate Ireland--fostering entrepreneurial activity through medical device innovation training.

    Science.gov (United States)

    Bruzzi, M S; Linehan, J H

    2013-09-01

    In the midst of a rich environment for medical device development and manufacturing, universities can play a critical role by developing relevant training programs to produce entrepreneurs who can be efficient and successful in creating early stage companies by understanding deeply the issues involved in creating a useful device, how to raise money, designing early clinical studies and locating manufacturing partners.

  5. Management information system of medical equipment using mobile devices

    Science.gov (United States)

    Núñez, C.; Castro, D.

    2011-09-01

    The large numbers of technologies currently incorporated into mobile devices transform them into excellent tools for capture and to manage the information, because of the increasing computing power and storage that allow to add many miscellaneous applications. In order to obtain benefits of these technologies, in the biomedical engineering field, it was developed a mobile information system for medical equipment management. The central platform for the system it's a mobile phone, which by a connection with a web server, it's capable to send and receive information relative to any medical equipment. Decoding a type of barcodes, known as QR-Codes, the management process is simplified and improved. These barcodes identified the medical equipments in a database, when these codes are photographed and decoded with the mobile device, you can access to relevant information about the medical equipment in question. This Project in it's actual state is a basic support tool for the maintenance of medical equipment. It is also a modern alternative, competitive and economic in the actual market.

  6. Stretchable bioelectronics for medical devices and systems

    CERN Document Server

    Ghaffari, Roozbeh; Kim, Dae-Hyeong

    2016-01-01

    This book highlights recent advances in soft and stretchable biointegrated electronics. A renowned group of authors address key ideas in the materials, processes, mechanics, and devices of soft and stretchable electronics; the wearable electronics systems; and bioinspired and implantable biomedical electronics. Among the topics discussed are liquid metals, stretchable and flexible energy sources, skin-like devices, in vitro neural recording, and more. Special focus is given to recent advances in extremely soft and stretchable bio-inspired electronics with real-world clinical studies that validate the technology. Foundational theoretical and experimental aspects are also covered in relation to the design and application of these biointegrated electronics systems. This is an ideal book for researchers, engineers, and industry professionals involved in developing healthcare devices, medical tools and related instruments relevant to various clinical practices.

  7. Medical devices for the anesthetist: current perspectives

    Directory of Open Access Journals (Sweden)

    Ingrande J

    2014-03-01

    Full Text Available Jerry Ingrande, Hendrikus JM LemmensDepartment of Anesthesiology, Perioperative and Pain Medicine, Stanford University School of Medicine, Stanford, CA, USAAbstract: Anesthesiologists are unique among most physicians in that they routinely use technology and medical devices to carry out their daily activities. Recently, there have been significant advances in medical technology. These advances have increased the number and utility of medical devices available to the anesthesiologist. There is little doubt that these new tools have improved the practice of anesthesia. Monitoring has become more comprehensive and less invasive, airway management has become easier, and placement of central venous catheters and regional nerve blockade has become faster and safer. This review focuses on key medical devices such as cardiovascular monitors, airway equipment, neuromonitoring tools, ultrasound, and target controlled drug delivery software and hardware. This review demonstrates how advances in these areas have improved the safety and efficacy of anesthesia and facilitate its administration. When applicable, indications and contraindications to the use of these novel devices will be explored as well as the controversies surrounding their use.Keywords: catheters, echocardiography, ultrasound, fiberoptic bronchoscope, laryngeal mask airway, closed-loop anesthesia

  8. 77 FR 18829 - Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2012-03-28

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-N-0001] Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY... public. Name of Committee: Gastroenterology and Urology Devices Panel of the Medical Devices Advisory...

  9. 76 FR 71983 - Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-11-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY... public. Name of Committee: Gastroenterology and Urology Devices Panel of the Medical Devices Advisory...

  10. Recent advances in medical device triage technologies for chemical, biological, radiological, and nuclear events.

    Science.gov (United States)

    Lansdowne, Krystal; Scully, Christopher G; Galeotti, Loriano; Schwartz, Suzanne; Marcozzi, David; Strauss, David G

    2015-06-01

    In 2010, the US Food and Drug Administration (Silver Spring, Maryland USA) created the Medical Countermeasures Initiative with the mission of development and promoting medical countermeasures that would be needed to protect the nation from identified, high-priority chemical, biological, radiological, or nuclear (CBRN) threats and emerging infectious diseases. The aim of this review was to promote regulatory science research of medical devices and to analyze how the devices can be employed in different CBRN scenarios. Triage in CBRN scenarios presents unique challenges for first responders because the effects of CBRN agents and the clinical presentations of casualties at each triage stage can vary. The uniqueness of a CBRN event can render standard patient monitoring medical device and conventional triage algorithms ineffective. Despite the challenges, there have been recent advances in CBRN triage technology that include: novel technologies; mobile medical applications ("medical apps") for CBRN disasters; electronic triage tags, such as eTriage; diagnostic field devices, such as the Joint Biological Agent Identification System; and decision support systems, such as the Chemical Hazards Emergency Medical Management Intelligent Syndromes Tool (CHEMM-IST). Further research and medical device validation can help to advance prehospital triage technology for CBRN events.

  11. 42 CFR 410.36 - Medical supplies, appliances, and devices: Scope.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Medical supplies, appliances, and devices: Scope... Services § 410.36 Medical supplies, appliances, and devices: Scope. (a) Medicare Part B pays for the following medical supplies, appliances and devices: (1) Surgical dressings, and splints, casts, and other...

  12. 75 FR 57968 - Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2010-09-23

    ...] Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY... public. Name of Committee: Gastroenterology and Urology Devices Panel of the Medical Devices Advisory... committee will discuss, make recommendations, and vote on information related to the PMA for the LAP-BAND...

  13. 76 FR 55398 - Immunology Devices Panel of the Medical Devices Advisory Committee: Notice of Postponement of...

    Science.gov (United States)

    2011-09-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] Immunology Devices Panel of the Medical Devices Advisory Committee: Notice of Postponement of Meeting AGENCY... postponing the meeting of the Immunology Devices Panel of the Medical Devices Advisory Committee scheduled...

  14. Open-Source Medical Devices (OSMD) Design of a Small Animal Radiotherapy System

    Science.gov (United States)

    Prajapati, S.; Mackie, T. R.; Jeraj, R.

    2014-03-01

    Open-Source Medical Devices (OSMD) was initiated with the goal of facilitating medical research by developing medical technologies including both hardware and software on an open-source platform. Our first project was to develop an integrated imaging and radiotherapy device for small animals that includes computed tomography (CT), positron emission tomography (PET) and radiation therapy (RT) modalities for which technical specifications were defined in the first OSMD conference held in Madison, Wisconsin, USA in December 2011. This paper specifically focuses on the development of a small animal RT (micro-RT) system by designing a binary micro multileaf collimator (bmMLC) and a small animal treatment planning system (SATPS) to enable intensity modulated RT (IMRT). Both hardware and software projects are currently under development and their current progresses are described. After the development, both bmMLC and TPS will be validated and commissioned for a micro-RT system. Both hardware design and software development will be open-sourced after completion.

  15. Additive Manufacturing for Robust and Affordable Medical Devices

    OpenAIRE

    Wolozny Gomez Robelo, Daniel Andre

    2016-01-01

    Additive manufacturing in the form of 3D printing is a revolutionary technology that has developed within the last two decades. Its ability to print an object with accurate features down to the micro scale have made its use in medical devices and research feasible. A range of life-saving technologies can now go from the laboratory and into field with the application of 3D-printing. This technology can be applied to medical diagnosis of patients in at-risk populations. Living biosensors a...

  16. A Medical Delivery Device

    DEFF Research Database (Denmark)

    2010-01-01

    The present invention relates to a medical delivery device comprising at least two membrane electrode assembly units each of which comprises three layers: an upper and a lower electrode and a selective ionic conductive membrane provided there-between. At least one of the three layers are shared...

  17. Handbook of materials for medical devices

    National Research Council Canada - National Science Library

    Davis, J. R

    2003-01-01

    ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Introduction Chapter 1 Overview of Biomaterials and Their Use in Medical Devices . . . . . . . . . . . . . . . . 1 Uses for Biomaterials...

  18. Value driven innovation in medical device design: a process for balancing stakeholder voices.

    Science.gov (United States)

    de Ana, F J; Umstead, K A; Phillips, G J; Conner, C P

    2013-09-01

    The innovation process has often been represented as a linear process which funnels customer needs through various business and process filters. This method may be appropriate for some consumer products, but in the medical device industry there are some inherent limitations to the traditional innovation funnel approach. In the medical device industry, there are a number of stakeholders who need to have their voices heard throughout the innovation process. Each stakeholder has diverse and unique needs relating to the medical device, the needs of one may highly affect the needs of another, and the relationships between stakeholders may be tenuous. This paper describes the application of a spiral innovation process to the development of a medical device which considers three distinct stakeholder voices: the Voice of the Customer, the Voice of the Business and the Voice of the Technology. The process is presented as a case study focusing on the front-end redesign of a class III medical device for an orthopedics company. Starting from project initiation and scope alignment, the process describes four phases, Discover, Envision, Create, and Refine, and concludes with value assessment of the final design features.

  19. Compiling a Medical Device File and a Proposal for an International Standard for Rehabilitation Robots

    NARCIS (Netherlands)

    Römer, GertWillem R.B.E.; Stuyt, Harry J.A.

    2007-01-01

    Medical devices produced by manufacturers are subject to regulatory review by authorities. Usually, medical devices are developed at universities and other research institutes. This implies that regulatory activities are to be carried out by the designer at these organizations also. And as early as

  20. BIOANALYTICAL STANDARDIZING FOR SEROLOGICAL DIAGNOSTIC MEDICAL DEVICES

    OpenAIRE

    A. Yu. Galkin; A. G. Komar; A. A. Grigorenko

    2015-01-01

    In article we analyzed national and international regulations concerning the quality and safety of medical devices for in vitro diagnostics. We discussed the possibility of a partial application of the recommendations of the State Pharmacopoeia of Ukraine to this type of product. The main guiding regulatory documents establishing requirements for quality and safety tools for the serological diagnosis products are The technical regulation on medical devices for the diagnosis in vitro, DSTU ISO...

  1. OR.NET: a service-oriented architecture for safe and dynamic medical device interoperability.

    Science.gov (United States)

    Kasparick, Martin; Schmitz, Malte; Andersen, Björn; Rockstroh, Max; Franke, Stefan; Schlichting, Stefan; Golatowski, Frank; Timmermann, Dirk

    2018-02-23

    Modern surgical departments are characterized by a high degree of automation supporting complex procedures. It recently became apparent that integrated operating rooms can improve the quality of care, simplify clinical workflows, and mitigate equipment-related incidents and human errors. Particularly using computer assistance based on data from integrated surgical devices is a promising opportunity. However, the lack of manufacturer-independent interoperability often prevents the deployment of collaborative assistive systems. The German flagship project OR.NET has therefore developed, implemented, validated, and standardized concepts for open medical device interoperability. This paper describes the universal OR.NET interoperability concept enabling a safe and dynamic manufacturer-independent interconnection of point-of-care (PoC) medical devices in the operating room and the whole clinic. It is based on a protocol specifically addressing the requirements of device-to-device communication, yet also provides solutions for connecting the clinical information technology (IT) infrastructure. We present the concept of a service-oriented medical device architecture (SOMDA) as well as an introduction to the technical specification implementing the SOMDA paradigm, currently being standardized within the IEEE 11073 service-oriented device connectivity (SDC) series. In addition, the Session concept is introduced as a key enabler for safe device interconnection in highly dynamic ensembles of networked medical devices; and finally, some security aspects of a SOMDA are discussed.

  2. 75 FR 61507 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of...

    Science.gov (United States)

    2010-10-05

    ...] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of Notice... announcing an amendment to the notice of meeting of the General and Plastic Surgery Devices Panel of the..., FDA announced that a meeting of the General and Plastic Surgery Devices Panel of the Medical Devices...

  3. Real-time volume rendering of digital medical images on an iOS device

    Science.gov (United States)

    Noon, Christian; Holub, Joseph; Winer, Eliot

    2013-03-01

    Performing high quality 3D visualizations on mobile devices, while tantalizingly close in many areas, is still a quite difficult task. This is especially true for 3D volume rendering of digital medical images. Allowing this would empower medical personnel a powerful tool to diagnose and treat patients and train the next generation of physicians. This research focuses on performing real time volume rendering of digital medical images on iOS devices using custom developed GPU shaders for orthogonal texture slicing. An interactive volume renderer was designed and developed with several new features including dynamic modification of render resolutions, an incremental render loop, a shader-based clipping algorithm to support OpenGL ES 2.0, and an internal backface culling algorithm for properly sorting rendered geometry with alpha blending. The application was developed using several application programming interfaces (APIs) such as OpenSceneGraph (OSG) as the primary graphics renderer coupled with iOS Cocoa Touch for user interaction, and DCMTK for DICOM I/O. The developed application rendered volume datasets over 450 slices up to 50-60 frames per second, depending on the specific model of the iOS device. All rendering is done locally on the device so no Internet connection is required.

  4. 75 FR 47606 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2010-08-06

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of... General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee scheduled for August...

  5. Monitoring of Vital Signs with Flexible and Wearable Medical Devices.

    Science.gov (United States)

    Khan, Yasser; Ostfeld, Aminy E; Lochner, Claire M; Pierre, Adrien; Arias, Ana C

    2016-06-01

    Advances in wireless technologies, low-power electronics, the internet of things, and in the domain of connected health are driving innovations in wearable medical devices at a tremendous pace. Wearable sensor systems composed of flexible and stretchable materials have the potential to better interface to the human skin, whereas silicon-based electronics are extremely efficient in sensor data processing and transmission. Therefore, flexible and stretchable sensors combined with low-power silicon-based electronics are a viable and efficient approach for medical monitoring. Flexible medical devices designed for monitoring human vital signs, such as body temperature, heart rate, respiration rate, blood pressure, pulse oxygenation, and blood glucose have applications in both fitness monitoring and medical diagnostics. As a review of the latest development in flexible and wearable human vitals sensors, the essential components required for vitals sensors are outlined and discussed here, including the reported sensor systems, sensing mechanisms, sensor fabrication, power, and data processing requirements. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. [Design and application of implantable medical device information management system].

    Science.gov (United States)

    Cao, Shaoping; Yin, Chunguang; Zhao, Zhenying

    2013-03-01

    Through the establishment of implantable medical device information management system, with the aid of the regional joint sharing of resources, we further enhance the implantable medical device traceability management level, strengthen quality management, control of medical risk.

  7. Metrological Reliability of Medical Devices

    Science.gov (United States)

    Costa Monteiro, E.; Leon, L. F.

    2015-02-01

    The prominent development of health technologies of the 20th century triggered demands for metrological reliability of physiological measurements comprising physical, chemical and biological quantities, essential to ensure accurate and comparable results of clinical measurements. In the present work, aspects concerning metrological reliability in premarket and postmarket assessments of medical devices are discussed, pointing out challenges to be overcome. In addition, considering the social relevance of the biomeasurements results, Biometrological Principles to be pursued by research and innovation aimed at biomedical applications are proposed, along with the analysis of their contributions to guarantee the innovative health technologies compliance with the main ethical pillars of Bioethics.

  8. Post market surveillance in the german medical device sector - current state and future perspectives.

    Science.gov (United States)

    Zippel, Claus; Bohnet-Joschko, Sabine

    2017-08-01

    Medical devices play a central role in the diagnosis and treatment of diseases but also bring the potential for adverse events, hazards or malfunction with serious consequences for patients and users. Medical device manufacturers are therefore required by law to monitor the performance of medical devices that have been approved by the competent authorities (post market surveillance). Conducting a nationwide online-survey in the German medical device sector in Q2/2014 in order to explore the current status of the use of post market instruments we obtained a total of 118 complete data sets, for a return rate of 36%. The survey included manufacturers of different sizes, producing medical devices of all risk classes. The post market instruments most frequently reported covered the fields of production monitoring and quality management as well as literature observation, regulatory vigilance systems, customer knowledge management and market observation while Post Market Clinical Follow-up and health services research were being used less for product monitoring. We found significant differences between the different risk classes of medical devices produced and the intensity of use of post market instruments. Differences between company size and the intensity of instruments used were hardly detected. Results may well contribute to the development of device monitoring which is a crucial element of the policy and regulatory system to identify device-related safety issues. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. 78 FR 16684 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2013-03-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  10. 77 FR 20642 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2012-04-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  11. 76 FR 14415 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-03-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  12. 76 FR 62419 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-10-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  13. 75 FR 49940 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2010-08-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  14. 78 FR 30928 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2013-05-23

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  15. 76 FR 39882 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-07-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0478] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  16. Design considerations for medical devices in the home environment.

    Science.gov (United States)

    Kaufman-Rivi, Diana; Collins-Mitchell, Janette; Jetley, Raoul

    2010-01-01

    Patient demographics, economic forces, and technological advancements contribute to the rise in home care services. Advanced medical devices and equipment originally designed for use by trained personnel in hospitals and clinics are increasingly migrating into the home. Unlike the clinical setting, the home is an uncontrolled environment with additional hazards. The compatibility of the device with the recipient's knowledge, abilities, lifestyle, and home environment plays a significant role in their therapy and rehabilitation. The advent of new device technologies such as wireless devices and interoperability of systems lends a new and complex perspective for medical device use in the home that must also be addressed. Adequately assessing and matching the patient and their caregiver with the appropriate device technology while considering the suitability of the home environment for device operation and maintenance is a challenge that relies on good human factors principles. There is a need to address these challenges in the growing home care sector In this article, the authors take a look at some important considerations and design issues for medical devices used in the home care environment.

  17. Implantable Medical Devices; Networking Security Survey

    Directory of Open Access Journals (Sweden)

    Siamak Aram

    2016-08-01

    Full Text Available The industry of implantable medical devices (IMDs is constantly evolving, which is dictated by the pressing need to comprehensively address new challenges in the healthcare field. Accordingly, IMDs are becoming more and more sophisticated. Not long ago, the range of IMDs’ technical capacities was expanded, making it possible to establish Internet connection in case of necessity and/or emergency situation for the patient. At the same time, while the web connectivity of today’s implantable devices is rather advanced, the issue of equipping the IMDs with sufficiently strong security system remains unresolved. In fact, IMDs have relatively weak security mechanisms which render them vulnerable to cyber-attacks that compromise the quality of IMDs’ functionalities. This study revolves around the security deficiencies inherent to three types of sensor-based medical devices; biosensors, insulin pump systems and implantable cardioverter defibrillators. Manufacturers of these devices should take into consideration that security and effectiveness of the functionality of implants is highly dependent on the design. In this paper, we present a comprehensive study of IMDs’ architecture and specifically investigate their vulnerabilities at networking interface.

  18. Initiatives in the Australian Medical Devices Industry

    International Nuclear Information System (INIS)

    Whelan, Luke

    2005-01-01

    The medical device industry is as diverse as it is specialised and calls on the innovative use of design and components and utilises all facets of precision manufacturing from printed circuit boards, injection-moulded plastics to engineering, using a wide range of materials. It generally requires exacting standards, starting with design, particularly for devices that are invasive or have direct contact with the human body. Of course this brings the further consideration of sterilisation and whether it is for single or multiple use. There is an ever-present need to produce more accurate less invasive and cheaper devices. The driving motivation appears to be meeting clinical needs at a reduced cost. The push to treat people outside the hospital is growing, creating new demands and directions. The advent of the Internet and wireless technology has opened a whole new direction of research and development opportunities

  19. Value-based purchasing of medical devices.

    Science.gov (United States)

    Obremskey, William T; Dail, Teresa; Jahangir, A Alex

    2012-04-01

    Health care in the United States is known for its continued innovation and production of new devices and techniques. While the intention of these devices is to improve the delivery and outcome of patient care, they do not always achieve this goal. As new technologies enter the market, hospitals and physicians must determine which of these new devices to incorporate into practice, and it is important these devices bring value to patient care. We provide a model of a physician-engaged process to decrease cost and increase review of physician preference items. We describe the challenges, implementation, and outcomes of cost reduction and product stabilization of a value-based process for purchasing medical devices at a major academic medical center. We implemented a physician-driven committee that standardized and utilized evidence-based, clinically sound, and financially responsible methods for introducing or consolidating new supplies, devices, and technology for patient care. This committee worked with institutional finance and administrative leaders to accomplish its goals. Utilizing this physician-driven committee, we provided access to new products, standardized some products, decreased costs of physician preference items 11% to 26% across service lines, and achieved savings of greater than $8 million per year. The implementation of a facility-based technology assessment committee that critically evaluates new technology can decrease hospital costs on implants and standardize some product lines.

  20. Medical instruments and devices principles and practices

    CERN Document Server

    Schreiner, Steven; Peterson, Donald R

    2015-01-01

    Medical Instruments and Devices: Principles and Practices originates from the medical instruments and devices section of The Biomedical Engineering Handbook, Fourth Edition. Top experts in the field provide material that spans this wide field. The text examines how biopotential amplifiers help regulate the quality and content of measured signals. It includes instruments and devices that span a range of physiological systems and the physiological scale: molecular, cellular, organ, and system. The book chronicles the evolution of pacemakers and their system operation and discusses oscillometry, cardiac output measurement, and the direct and indirect methods of measuring cardiac output. The authors also expound on the mechanics and safety of defibrillators and cover implantable stimulators, respiration, and the structure and function of mechanical ventilators. In addition, this text covers in depth: Anesthesia Delivery Electrosurgical Units and Devices Biomedical Lasers Measuring Cellular Traction Forces Blood G...

  1. Instructions included? Make safety training part of medical device procurement process.

    Science.gov (United States)

    Keller, James P

    2010-04-01

    Before hospitals embrace new technologies, it's important that medical personnel agree on how best to use them. Likewise, hospitals must provide the support to operate these sophisticated devices safely. With this in mind, it's wise for hospitals to include medical device training in the procurement process. Moreover, purchasing professionals can play a key role in helping to increase the amount of user training for medical devices and systems. What steps should you take to help ensure that new medical devices are implemented safely? Here are some tips.

  2. 77 FR 14272 - Medical Devices; Immunology and Microbiology Devices; Classification of Norovirus Serological...

    Science.gov (United States)

    2012-03-09

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 866 [Docket No. FDA-2012-N-0165] Medical Devices; Immunology and Microbiology Devices; Classification of Norovirus... AND MICROBIOLOGY DEVICES 0 1. The authority citation for 21 CFR part 866 continues to read as follows...

  3. Medical devices and the Middle East: market, regulation, and reimbursement in Gulf Cooperation Council states

    Directory of Open Access Journals (Sweden)

    Howard JJ

    2014-11-01

    Full Text Available Jason J Howard Division of Paediatric Orthopaedics, Department of Surgery, Sidra Medical and Research Center, Doha, Qatar Abstract: With some of the richest economies in the world, the Gulf Cooperation Council (GCC is undergoing rapid growth not only in its population but also in health care expenditure. Despite the GCC's abundance of hydrocarbon-based wealth, the drivers of the medical device industry in the GCC are still in flux, with gains yet to be made in areas of infrastructure, regulation, and reimbursement. However, the regional disease burden, expanding health insurance penetration, increasing privatization, and a desire to attract skilled expatriate health care providers have led to favorable conditions for the medical device market in the GCC. The purpose of this article is to investigate the current state of the GCC medical device industry, with respect to market, regulation, and reimbursement, paying special attention to the three largest medical device markets: Saudi Arabia, the United Arab Emirates, and Qatar. The GCC would seem to represent fertile ground for the development of medical technologies, especially those in line with the regional health priorities of the respective member states. Keywords: medical devices, regulation, reimbursement, Middle East 

  4. Medical and welfare device session. Toward medical treatment and welfare of tomorrow; Iryo fukushi kiki session. Ashita no iryo fukushi ni mukete

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-09-01

    This paper is the material distributed in the medical and welfare device session held under the auspices of NEDO in September 2000. Diversification of needs in the medical and welfare areas and handling of age advancement are the growing issue. NEDO is putting efforts toward enhancement of quality of life (QOL) and realization of the nation with great life by providing high-quality and high-efficiency medical and welfare services. The NEDO's efforts cover the areas of treating adult diseases such as cancers and cardiac diseases whose seriousness is growing, early diagnoses of diseases, medical treatment with low invasion, elderly people helping, reduction of helpers' burden, reduction of handicaps to elderly people and mentally and physically handicapped persons, and assistance to participation in the society. To achieve these goals, NEDO is implementing the following four projects: research and development of medical and welfare device technologies, researches of medical science and engineering collaboration type, and promotion of developing welfare techno-systems and practical application of welfare appliances. Developments are being made toward practical application of medical and welfare devices with excellent safety and convenience, of low cost and high performance. The session gave the keynote addresses related to medical treatment and prevention of brain diseases; brain, the universe and MRI (the world of mind as seen in images), and high-tech medical treatments to protect brain (challenge to brain that starts now). (NEDO)

  5. Commercial viability of medical devices using Headroom and return on investment calculation

    NARCIS (Netherlands)

    Markiewicz, Katarzyna; van Til, Janine Astrid; Steuten, Lotte Maria Gertruda; IJzerman, Maarten Joost

    2016-01-01

    The market success of a medical product depends on its commercial viability, yet this may be hard to predict during the development process of medical devices. This paper aims to determine if applying the Headroom method combined with return on investment (ROI) analysis allows for estimation of the

  6. INTERFACE ELECTRONIC MEDICAL CARD ON MOBILE DEVICE

    Directory of Open Access Journals (Sweden)

    Y. L. Nechyporenko

    2013-05-01

    Full Text Available The concept designed by electronic medical card for heterogeneous environment of medical information systems at various levels. Appropriate model and technical solution. Done evaluating operating systems for mobile devices. Designed and produced by the project mobile application on Android OS as an electronic medical record on a Tablet PC Acer.

  7. Development of a handmade device for collimation and central ray alignment tests in medical X-ray equipment

    International Nuclear Information System (INIS)

    Cruz, B.L. da; Brito, E.B.; Gomes, A.S.

    2017-01-01

    Ordinance 453/98 of the Ministry of Health establishes that medical X-ray equipment should be monitored by tests that prove its efficiency. This practice is called quality control (QC), and two important tests jointly evaluate the operation of the collimation and alignment systems of the central axis of the X-ray beam. The low supply and the high cost generate allegations of difficulties in the periodic realization of the tests. The aim of this work is to design, make and evaluate the performance of a handmade device for the mentioned tests, using low cost materials. Once built, the device had its performance evaluated and compared with the traditionally marketed device. The handmade device proved to be fit in its functions. It is possible to make a device that tests X-ray medical equipment, using the radiology technologist himself as the test runner. Radiation protection is promoted and legislation with no real financial burden

  8. Growing pains: medical device interoperability. Regulators and new standards are helping to bring about the convergence of medical devices and information management systems on IT networks.

    Science.gov (United States)

    Degaspari, John

    2011-07-01

    Both provider organizations and medical device vendors have made significant, if slow-going, progress over the last several years to network their digitally-enabled medical devices. Recent strides in both the regulatory and standards arenas have provided renewed impetus on the part of both stakeholder groups to bring more interoperability to disparate medical devices, resulting in better security and quality of patient data.

  9. 78 FR 18233 - Medical Devices; Technical Amendment

    Science.gov (United States)

    2013-03-26

    ... human environment. Therefore, neither an environmental assessment nor an environmental impact statement..., Confidential business information, Medical devices, Medical research, Reporting and recordkeeping requirements... revising the second sentence in paragraph (a) to read as follows: Sec. 870.3600 External pacemaker pulse...

  10. Medical Device Plug-and-Play Interoperability Standards and Technology Leadership

    Science.gov (United States)

    2016-10-01

    death,” The Boston Globe, April 3 2010. 27. Arney D, Pajic M, Goldman JM, Lee I, Mangharam R, Sokolsky O, “Toward Patient Safety in Closed - Loop Medical ...becoming increasingly clear. We have been providing medical device interoperability domain expertise to assist the Veterans Administration in a...15. Wallroth C, Goldman J, Manigel J, Osborn D, Roellike T, Weininger S, Westenskow D, “Development of a Standard for Physiologic Closed Loop

  11. NF EN ISO 11137-1, July 2006. Sterilization of health care products - Irradiation - Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices

    International Nuclear Information System (INIS)

    2006-01-01

    This part of the ISO 11137 standard specifies requirements for the development, validation and routine control of a radiation sterilization process for medical devices. Although the scope of this part of the ISO 11137 standard is limited to medical devices, it specifies requirements and provides guidance that may be applicable to other products and equipment. This part of the international standard covers radiation processes employing irradiators using the radionuclide 60 Co or 137 Cs, a beam from an electron generator or a beam from an X-ray generator. This part of the international standard does not: - specify requirements for development, validation and routine control of a process for inactivating the causative agents of spongiform encephalopathies such as scrapie, bovine spongiform encephalopathy and Creutzfeldt-Jakob disease; - detail specified requirements for designating a medical device as sterile; - specify a quality management system for the control of all stages of production of medical devices; - specify requirements for occupational safety associated with the design and operation of irradiation facilities; - specify requirements for the sterilization of used or reprocessed devices

  12. Wireless energy transfer platform for medical sensors and implantable devices.

    Science.gov (United States)

    Zhang, Fei; Hackworth, Steven A; Liu, Xiaoyu; Chen, Haiyan; Sclabassi, Robert J; Sun, Mingui

    2009-01-01

    Witricity is a newly developed technique for wireless energy transfer. This paper presents a frequency adjustable witricity system to power medical sensors and implantable devices. New witricity resonators are designed for both energy transmission and reception. A prototype platform is described, including an RF power source, two resonators with new structures, and inductively coupled input and output stages. In vitro experiments, both in open air and using a human head phantom consisting of simulated tissues, are employed to verify the feasibility of this platform. An animal model is utilized to evaluate in vivo energy transfer within the body of a laboratory pig. Our experiments indicate that witricity is an effective new tool for providing a variety of medical sensors and devices with power.

  13. 76 FR 65200 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee: Notice of...

    Science.gov (United States)

    2011-10-20

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee: Notice of... Administration (FDA) is postponing the meeting of the General and Plastic Surgery Devices Panel of the Medical...

  14. Practical design control implementation for medical devices

    CERN Document Server

    Justiniano, Jose

    2003-01-01

    Bringing together the concepts of design control and reliability engineering, this book is a must for medical device manufacturers. It helps them meet the challenge of designing and developing products that meet or exceed customer expectations and also meet regulatory requirements. Part One covers motivation for design control and validation, design control requirements, process validation and design transfer, quality system for design control, and measuring design control program effectiveness. Part Two discusses risk analysis and FMEA, designing-in reliability, reliability and design verific

  15. Development of an Official Guideline for the Economic Evaluation of Drugs/Medical Devices in Japan.

    Science.gov (United States)

    Shiroiwa, Takeru; Fukuda, Takashi; Ikeda, Shunya; Takura, Tomoyuki; Moriwaki, Kensuke

    2017-03-01

    In Japan, cost-effectiveness evaluation was implemented on a trial basis from fiscal year 2016. The results will be applied to the future repricing of drugs and medical devices. On the basis of a request from the Central Social Insurance Medical Council (Chuikyo), our research team drafted the official methodological guideline for trial implementation. Here, we report the process of developing and the contents of the official guideline for cost-effectiveness evaluation. The guideline reflects discussions at the Chuikyo subcommittee (e.g., the role of quality-adjusted life-year) and incorporates our academic perspective. Team members generated research questions for each section of the guideline and discussions on these questions were carried out. A draft guideline was prepared and submitted to the Ministry of Health, Labour and Welfare (MHLW), and then to the subcommittee. The draft guideline was revised on the basis of the discussions at the subcommitte, if appropriate. Although the "public health care payer's perspective" is standard in this guideline, other perspectives can be applied as necessary depending on the objective of analysis. On the basis of the discussions at the subcommittee, quality-adjusted life-year will be used as the basic outcome. A discount rate of 2% per annum for costs and outcomes is recommended. The final guideline was officially approved by the Chuikyo general assembly in February 2016. This is the first officially approved guideline for the economic evaluation of drugs and medical devices in Japan. The guideline is expected to improve the quality and comparability of submitted cost-effectiveness data for decision making. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  16. Electronic medical devices: a primer for pathologists.

    Science.gov (United States)

    Weitzman, James B

    2003-07-01

    Electronic medical devices (EMDs) with downloadable memories, such as implantable cardiac pacemakers, defibrillators, drug pumps, insulin pumps, and glucose monitors, are now an integral part of routine medical practice in the United States, and functional organ replacements, such as the artificial heart, pancreas, and retina, will most likely become commonplace in the near future. Often, EMDs end up in the hands of the pathologist as a surgical specimen or at autopsy. No established guidelines for systematic examination and reporting or comprehensive reviews of EMDs currently exist for the pathologist. To provide pathologists with a general overview of EMDs, including a brief history; epidemiology; essential technical aspects, indications, contraindications, and complications of selected devices; potential applications in pathology; relevant government regulations; and suggested examination and reporting guidelines. Articles indexed on PubMed of the National Library of Medicine, various medical and history of medicine textbooks, US Food and Drug Administration publications and product information, and specifications provided by device manufacturers. Studies were selected on the basis of relevance to the study objectives. Descriptive data were selected by the author. Suggested examination and reporting guidelines for EMDs received as surgical specimens and retrieved at autopsy. Electronic medical devices received as surgical specimens and retrieved at autopsy are increasing in number and level of sophistication. They should be systematically examined and reported, should have electronic memories downloaded when indicated, will help pathologists answer more questions with greater certainty, and should become an integral part of the formal knowledge base, research focus, training, and practice of pathology.

  17. The Style Evolution of Glasses: Acknowledging Well-being for Wearable Medical Device

    Directory of Open Access Journals (Sweden)

    Lydia Royeen

    2015-10-01

    Full Text Available The focus of Peta Bush’s work is to create wearable medical devices that address all qualities of the individual, including physical, mental, emotional, and psychosocial aspects. Peta is completing a practice-based research PhD titled “Therapeutic jewelry: The craft of people-centric devices for wellbeing.” Her passion for creating wearable medical devices that are multi-dimensional stems from her personal experiences, as she has Ehlers-Danlos syndrome. In addition, she uses her knowledge of well-being and the biopsychosocial model when creating her wearable medical devices. Peta currently uses technology, such as 3D printing, as one method to fabricate her collection. Her aspirations are for this concept of wearable medical devices to become mainstream, similar to glasses, and to remove the stigma associated with wearable medical devices.

  18. 78 FR 12329 - Distinguishing Medical Device Recalls From Product Enhancements; Reporting Requirements; Draft...

    Science.gov (United States)

    2013-02-22

    ... medical devices to take timely action to correct violative devices or remove them from the marketplace...] Distinguishing Medical Device Recalls From Product Enhancements; Reporting Requirements; Draft Guidance for... draft guidance entitled ``Distinguishing Medical Device Recalls From Product Enhancements; Reporting...

  19. High-risk medical devices, children and the FDA: regulatory challenges facing pediatric mechanical circulatory support devices.

    Science.gov (United States)

    Almond, Christopher S D; Chen, Eric A; Berman, Michael R; Less, Joanne R; Baldwin, J Timothy; Linde-Feucht, Sarah R; Hoke, Tracey R; Pearson, Gail D; Jenkins, Kathy; Duncan, Brian W; Zuckerman, Bram D

    2007-01-01

    Pediatric mechanical circulatory support is a critical unmet need in the United States. Infant- and child-sized ventricular assist devices are currently being developed largely through federal contracts and grants through the National Heart, Lung, and Blood Institute (NHLBI). Human testing and marketing of high-risk devices for children raises epidemiologic and regulatory issues that will need to be addressed. Leaders from the US Food and Drug Administration (FDA), NHLBI, academic pediatric community, and industry convened in January 2006 for the first FDA Workshop on the Regulatory Process for Pediatric Mechanical Circulatory Support Devices. The purpose was to provide the pediatric community with an overview of the federal regulatory process for high-risk medical devices and to review the challenges specific to the development and regulation of pediatric mechanical circulatory support devices. Pediatric mechanical circulatory support present significant epidemiologic, logistic, and financial challenges to industry, federal regulators, and the pediatric community. Early interactions with the FDA, shared appreciation of challenges, and careful planning will be critical to avoid unnecessary delays in making potentially life-saving devices available for children. Collaborative efforts to address these challenges are warranted.

  20. [Thoughts on the Witnessed Audit in Medical Device Single Audit Program].

    Science.gov (United States)

    Wen, Jing; Xiao, Jiangyi; Wang, Aijun

    2018-02-08

    Medical Device Single Audit Program is one of the key projects in International Medical Device Regulators Forum, which has much experience to be used for reference. This paper briefly describes the procedures and contents of the Witnessed Audit in Medical Device Single Audit Program. Some revelations about the work of Witnessed Audit have been discussed, for reference by the Regulatory Authorities and the Auditing Organizations.

  1. Medical diagnostics with mobile devices: Comparison of intrinsic and extrinsic sensing.

    Science.gov (United States)

    Kwon, L; Long, K D; Wan, Y; Yu, H; Cunningham, B T

    2016-01-01

    We review the recent development of mobile detection instruments used for medical diagnostics, and consider the relative advantages of approaches that utilize the internal sensing capabilities of commercially available mobile communication devices (such as smartphones and tablet computers) compared to those that utilize a custom external sensor module. In this review, we focus specifically upon mobile medical diagnostic platforms that are being developed to serve the need in global health, personalized medicine, and point-of-care diagnostics. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. 75 FR 68200 - Medical Devices; Radiology Devices; Reclassification of Full-Field Digital Mammography System

    Science.gov (United States)

    2010-11-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 892 [Docket No. FDA-2008-N-0273] Medical Devices; Radiology Devices; Reclassification of Full- Field Digital... and Drugs, 21 CFR part 892 is amended as follows: PART 892--RADIOLOGY DEVICES 0 1. The authority...

  3. Identification of Bodies by Unique Serial Numbers on Implanted Medical Devices.

    Science.gov (United States)

    Blessing, Melissa M; Lin, Peter T

    2018-05-01

    Visual identification is the most common identification method used by medical examiners but is not always possible. Alternative methods include X-ray, fingerprint, or DNA comparison, but these methods require additional resources. Comparison of serial numbers on implanted medical devices is a rapid and definitive method of identification. To assess the practicality of using this method, we reviewed 608 consecutive forensic autopsies performed at a regional medical examiner office. Of these, 56 cases required an alternative method of identification due to decomposition (n = 35), gunshot wound (n = 9), blunt trauma (n = 6), or charring (n = 6). Of these 56 cases, eight (14.3%) were known to have an implanted medical device. Of these eight cases, five (63%) could be positively identified by comparing serial numbers. If an implanted medical device is known to be present, and medical records are available, identification by medical device serial number should be a first-line method. © 2017 American Academy of Forensic Sciences.

  4. Medical applications for pharmacists using mobile devices.

    Science.gov (United States)

    Aungst, Timothy Dy

    2013-01-01

    Mobile devices (eg, smartphones, tablet computers) have become ubiquitous and subsequently there has been a growth in mobile applications (apps). Concurrently, mobile devices have been integrated into health care practice due to the availability and quality of medical apps. These mobile medical apps offer increased access to clinical references and point-of-care tools. However, there has been little identification of mobile medical apps suitable for the practice of pharmacy. To address the shortage of recommendations of mobile medical apps for pharmacists in daily practice. Mobile medical apps were identified via the iTunes and Google Play Stores via the "Medical" app categories and key word searches (eg, drug information, medical calculators). In addition, reviews provided by professional mobile medical app review websites were used to identify apps. Mobile medical apps were included if they had been updated in the previous 3 months, were available in the US, used evidence-based information or literature support, had dedicated app support, and demonstrated stability. Exclusion criteria included apps that were not available in English, had advertisement bias, used nonreferenced sources, were available only via an institution-only subscription, and were web-based portals. Twenty-seven mobile apps were identified and reviewed that involved general pharmacy practice, including apps that involved drug references, clinical references, medical calculators, laboratory references, news and continuing medical education, and productivity. Mobile medical apps have a variety of features that are beneficial to pharmacy practice. Individual clinicians should consider several characteristics of these apps to determine which are suitable to incorporate into their daily practice.

  5. 21 CFR 801.122 - Medical devices for processing, repacking, or manufacturing.

    Science.gov (United States)

    2010-04-01

    ....122 Medical devices for processing, repacking, or manufacturing. A device intended for processing... act if its label bears the statement “Caution: For manufacturing, processing, or repacking”. ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical devices for processing, repacking, or...

  6. Medical device problem reporting for the betterment of healthcare.

    Science.gov (United States)

    1998-08-01

    Given that there are nearly 5,000 individual classes of medical devices, tens of thousands of medical device suppliers, and millions of healthcare providers around the world, device-related problems are bound to happen. But effective problem reporting can help reduce or eliminate many of these problems--not only within an institution, but also potentially around the world. In this article, we trace the problem reporting process from its beginnings in the hospital to its global impact in making critical information available throughout the healthcare community.

  7. Home Healthcare Medical Devices: A Checklist

    Science.gov (United States)

    ... not using it. Contact your doctor and home healthcare team often to review your health condition. * Check ... assurance of their safety and effectiveness. A home healthcare medical device is any product or equipment used ...

  8. Radiation sterilization of medical devices

    International Nuclear Information System (INIS)

    Kaluska, I.; Stuglik, Z.

    1996-01-01

    Overview of sterilization methods of medical devices has been given, with the special stress put on radiation sterilization. A typical validation program for radiation sterilization has been shown and also a comparison of European and ISO standards concerning radiation sterilization has been discussed. (author). 13 refs, 1 fig., 2 tabs

  9. 77 FR 19534 - Medical Devices; Immunology and Microbiology Devices; Classification of Norovirus Serological...

    Science.gov (United States)

    2012-04-02

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 866 [Docket No. FDA-2012-N-0165] Medical Devices; Immunology and Microbiology Devices; Classification of Norovirus Serological Reagents; Correction AGENCY: Food and Drug Administration, HHS. ACTION: Final rule; correction...

  10. BIOANALYTICAL STANDARDIZING FOR SEROLOGICAL DIAGNOSTIC MEDICAL DEVICES

    Directory of Open Access Journals (Sweden)

    A. Yu. Galkin

    2015-04-01

    Full Text Available In article we analyzed national and international regulations concerning the quality and safety of medical devices for in vitro diagnostics. We discussed the possibility of a partial application of the recommendations of the State Pharmacopoeia of Ukraine to this type of product. The main guiding regulatory documents establishing requirements for quality and safety tools for the serological diagnosis products are The technical regulation on medical devices for the diagnosis in vitro, DSTU ISO 13485 “Medical devices. Quality management system. Regulatory requirements”, and DSTU ISO/IEC 17025 “General requirements for the competence of testing and calibration laboratories”. Similar requirements of the State Pharmacopoeia of Ukraine which are used for drug standardization can not be directly applied to the medical devises for in vitro diagnostics due to a number of features, namely, the serological diagnosis products pre-designed to determine the unknown concentration of a particular analyte in a biological material, the diagnostic kits has to include the control samples (internal standard systems that need to be calibrated. It was determined following parameters of bioanalytical standardization and validation characterization for of qualitative (semi quantitative test-kits for serological diagnosis: precision (convergence, intralaboratory precision and reproducibility, diagnostic and analytical specificity, diagnostic sensitivity. It’s necessary to inspect additional parameters for quantitative test-kits such as accuracy (precision, linearity, analytical sensitivity and range.

  11. Biomaterials in medical devices: an interview with Jörg Vienken of Fresenius Medical Care, Germany.

    Science.gov (United States)

    Vienken, Jörg

    2012-06-01

    Biomaterial and biopolymer research have significant impact on the development as well as application of biotechnology. Biotechnology Journal recently attended the "Nanomaterials for Biomedical Technologies 2012" conference. We were privileged to have the opportunity to ask Prof. Dr. Jörg Vienken, VP of BioSciences at Fresenius Medical Care, a few questions relating to medical devices, the importance of publishing for industry, and also his advice for young scientists/engineers looking for a career in industry. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Liability for damage caused by shortage and failure to use necessary medical devices

    Directory of Open Access Journals (Sweden)

    Cvetković Mihajlo

    2014-01-01

    Full Text Available In order to provide for successful, safe and high quality medical services, health care institutions need to be equipped with adequate medical devices. For this reason, every medical institution is legally obliged to have relevant medical devices. In case a patient has been deprived of some medical service for the lack of necessary medical devices (which the institution has been obliged to provide, the medical institution is responsible for the damage and harm sustained by the patient. The responsibility implies non-contractual liability (in tort law or pre-contractual liability (in contract law. In both cases, the liability is based on the presumed culpability. In order to be excluded from liability, the medical institution has to prove that the patient has been deprived of medical service (or that the institution has refused to enter into a medical service provider agreement on justifiable grounds, i.e. due to the lack of necessary medical devices. On the other hand, in case the medial institutions fail to provide needed care or violate their obligation to use medical devices when necessary, it is regarded as medical negligence (professional error. In most cases, it implies the liability of medical institutions for damage, injury or harm caused to the patient by medical services provided without applying a relevant medical device, whose use has been medically indicated. The liability is even more substantial in cases where the medical device has been available but the medical institutions has not applied it in medial treatment (even though its use has been medically indicated; such conduct is qualified as gross negligence.

  13. Design controls for the medical device industry

    CERN Document Server

    Teixeira, Marie B

    2013-01-01

    The second edition of a bestseller, Design Controls for the Medical Device Industry provides a comprehensive review of the latest design control requirements, as well as proven tools and techniques to ensure your company's design control program evolves in accordance with current industry practice. The text assists in the development of an effective design control program that not only satisfies the US FDA Quality System Regulation (QSR) and ISO 9001 and 13485 standards, but also meets today's third-party auditor/investigator expectations and saves you valuable time and money.The author's cont

  14. Medical devices and the Middle East: market, regulation, and reimbursement in Gulf Cooperation Council states.

    Science.gov (United States)

    Howard, Jason J

    2014-01-01

    With some of the richest economies in the world, the Gulf Cooperation Council (GCC) is undergoing rapid growth not only in its population but also in health care expenditure. Despite the GCC's abundance of hydrocarbon-based wealth, the drivers of the medical device industry in the GCC are still in flux, with gains yet to be made in areas of infrastructure, regulation, and reimbursement. However, the regional disease burden, expanding health insurance penetration, increasing privatization, and a desire to attract skilled expatriate health care providers have led to favorable conditions for the medical device market in the GCC. The purpose of this article is to investigate the current state of the GCC medical device industry, with respect to market, regulation, and reimbursement, paying special attention to the three largest medical device markets: Saudi Arabia, the United Arab Emirates, and Qatar. The GCC would seem to represent fertile ground for the development of medical technologies, especially those in line with the regional health priorities of the respective member states.

  15. Medical Device Plug-and-Play Interoperability Standards and Technology Leadership

    Science.gov (United States)

    2017-10-01

    Award Number: W81XWH-09-1-0705 TITLE: “Medical Device Plug-and-Play Interoperability Standards and Technology Leadership” PRINCIPAL INVESTIGATOR...Sept 2016 – 20 Sept 2017 4. TITLE AND SUBTITLE “Medical Device Plug-and-Play Interoperability 5a. CONTRACT NUMBER Standards and Technology ...efficiency through interoperable medical technologies . We played a leadership role on interoperability safety standards (AAMI, AAMI/UL Joint

  16. Transmitting patient and device data via GSM--central management for decentral mobile medical devices.

    Science.gov (United States)

    Bachmor, T; Schöchlin, J; Bolz, A

    2002-01-01

    Equipping medical devices with long range telemetry opens completely new possibilities for emergency response, home care and remote diagnosis. Mobile communications nowadays seem to be a generally accepted part of our modern world, but bridging the gap between new (consumer-) technologies and medical devices still is a challenge today. Providing a telemetry link (GSM) is just the trivial part--ensuring security, reliability and service management are the more critical tasks that need to be addressed. Therefore, a complete system concept consists of an automatic fleet management (e.g. periodic device-initiated service calls) as well as customer relationship management (CRM), including technical service and a trouble-ticket system.

  17. Medical device integration: CIOs must bridge the digital divide between devices and electronic medical records.

    Science.gov (United States)

    Raths, David

    2009-02-01

    To get funding approved for medical device integration, ClOs suggest focusing on specific patient safety or staff efficiency pain points. Organizations that make clinical engineering part of their IT team report fewer chain-of-command issues. It also helps IT people understand the clinical goals because the engineering people have been working closely with clinicians for years. A new organization has formed to work on collaboration between clinical engineers and IT professionals. For more information, go to www.ceitcollaboration.org. ECRI Institute has written a guide to handling the convergence of medical technology and hospital networks. Its "Medical Technology for the IT Professional: An Essential Guide for Working in Today's Healthcare Setting" also details how IT professionals can assist hospital technology planning and acquisition, and provide ongoing support for IT-based medical technologies. For more information, visit www.ecri.org/ITresource.

  18. Cybersecurity and medical devices: A practical guide for cardiac electrophysiologists

    Science.gov (United States)

    Kramer, Daniel B.; Foo Kune, Denis; Auto de Medeiros, Julio; Yan, Chen; Xu, Wenyuan; Crawford, Thomas; Fu, Kevin

    2017-01-01

    Abstract Medical devices increasingly depend on software. While this expands the ability of devices to perform key therapeutic and diagnostic functions, reliance on software inevitably causes exposure to hazards of security vulnerabilities. This article uses a recent high‐profile case example to outline a proactive approach to security awareness that incorporates a scientific, risk‐based analysis of security concerns that supports ongoing discussions with patients about their medical devices. PMID:28512774

  19. Sterilization of health care products - Radiation. Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices

    International Nuclear Information System (INIS)

    2006-01-01

    reproducible so that predictions can be made, with reasonable confidence, that there is a low level of probability of there being a viable microorganism present on product after sterilization. Specification of this probability is a matter for regulatory authorities and may vary from country to country (see, for example, EN 556-1 and ANSI/AAMI ST67). Generic requirements of the quality management system for design and development, production, installation and servicing are given in ISO 9001 and particular requirements for quality management systems for medical device production are given in ISO 13485. The standards for quality management systems recognise that, for certain processes used in manufacturing, the effectiveness of the process cannot be fully verified by subsequent inspection and testing of the product. Sterilization is an example of such a process. For this reason, sterilization processes are validated for use, the performance of the sterilization process is monitored routinely and the equipment is maintained. Exposure to a properly validated, accurately controlled sterilization process is not the only factor associated with the provision of reliable assurance that the products are sterile and, in this regard, suitable for its intended use. Attention is therefore given to a number of considerations including: a) the microbiological status of incoming raw materials and/or components; b) the validation and routine control of any cleaning and disinfection procedures used on the product; c) the control of the environment in which the product is manufactured, assembled and packaged; d) the control of equipment and processes; e) the control of personnel and their hygiene; f) the manner and materials in which the product is packaged; g) the conditions under which product is stored. This part of ISO 11137 describes the requirements for ensuring that the activities associated with the process of radiation sterilization are performed properly. These activities are described

  20. Medical device registration, agreements on mutual recognition - a step forward to global harmonization?

    International Nuclear Information System (INIS)

    Eidenberger, R.Reiner

    2000-01-01

    The purpose of this article is to give a short overview of some different regulations in Europe and the United States with regard to the clearance of medical devices and to give an outlook of what the Agreements on Mutual Recognition will bring in terms of Global Harmonization. Recent European legislation, the Council Directive 93/42/EEC of 14 June 1993 concerning medical devices (Medical Device Directive, MDD), requires that all medical devices placed on the European market bear the CE marking. From 14 June 1998, medical devices fall under the scope of this European Medical Device Directive and there is a harmonization within the European market. Similar to this, but for another market, are the USA FDA requirements, Premarket Approval (PMA) and Premarket notification (510(k)). The same medical device, the same goal - a safe product - but different legislation and thus duplication of registration procedures. The European Commission is presently discussing a series of agreements with third countries, Australia, New Zealand, USA, Canada, Japan and Eastern European countries wishing to join the EU, concerning the mutual acceptance of inspection bodies and, ultimately, proof of conformity (for example reports on examination, certificates, licenses and marks of conformity) in connection with medical devices. Meanwhile agreements with Australia, New Zealand, USA and Canada came into force. (author)

  1. A service protocol for post-processing of medical images on the mobile device

    Science.gov (United States)

    He, Longjun; Ming, Xing; Xu, Lang; Liu, Qian

    2014-03-01

    With computing capability and display size growing, the mobile device has been used as a tool to help clinicians view patient information and medical images anywhere and anytime. It is uneasy and time-consuming for transferring medical images with large data size from picture archiving and communication system to mobile client, since the wireless network is unstable and limited by bandwidth. Besides, limited by computing capability, memory and power endurance, it is hard to provide a satisfactory quality of experience for radiologists to handle some complex post-processing of medical images on the mobile device, such as real-time direct interactive three-dimensional visualization. In this work, remote rendering technology is employed to implement the post-processing of medical images instead of local rendering, and a service protocol is developed to standardize the communication between the render server and mobile client. In order to make mobile devices with different platforms be able to access post-processing of medical images, the Extensible Markup Language is taken to describe this protocol, which contains four main parts: user authentication, medical image query/ retrieval, 2D post-processing (e.g. window leveling, pixel values obtained) and 3D post-processing (e.g. maximum intensity projection, multi-planar reconstruction, curved planar reformation and direct volume rendering). And then an instance is implemented to verify the protocol. This instance can support the mobile device access post-processing of medical image services on the render server via a client application or on the web page.

  2. 77 FR 4252 - Additional Spectrum for the Medical Device Radiocommunication Service

    Science.gov (United States)

    2012-01-27

    ... licensed users in these frequency bands to continue providing service. Medical Micro-Power Networks (MMNs...). Under this approach, medical devices would operate in the band on a shared, non-exclusive basis with...Radio Service rules for devices operating in the 413-457 MHz band. These definitions were for a Medical...

  3. Design of point-of-care (POC) microfluidic medical diagnostic devices

    Science.gov (United States)

    Leary, James F.

    2018-02-01

    Design of inexpensive and portable hand-held microfluidic flow/image cytometry devices for initial medical diagnostics at the point of initial patient contact by emergency medical personnel in the field requires careful design in terms of power/weight requirements to allow for realistic portability as a hand-held, point-of-care medical diagnostics device. True portability also requires small micro-pumps for high-throughput capability. Weight/power requirements dictate use of super-bright LEDs and very small silicon photodiodes or nanophotonic sensors that can be powered by batteries. Signal-to-noise characteristics can be greatly improved by appropriately pulsing the LED excitation sources and sampling and subtracting noise in between excitation pulses. The requirements for basic computing, imaging, GPS and basic telecommunications can be simultaneously met by use of smartphone technologies, which become part of the overall device. Software for a user-interface system, limited real-time computing, real-time imaging, and offline data analysis can be accomplished through multi-platform software development systems that are well-suited to a variety of currently available cellphone technologies which already contain all of these capabilities. Microfluidic cytometry requires judicious use of small sample volumes and appropriate statistical sampling by microfluidic cytometry or imaging for adequate statistical significance to permit real-time (typically medical decisions for patients at the physician's office or real-time decision making in the field. One or two drops of blood obtained by pin-prick should be able to provide statistically meaningful results for use in making real-time medical decisions without the need for blood fractionation, which is not realistic in the field.

  4. Optical tests for using smartphones inside medical devices

    Science.gov (United States)

    Bernat, Amir S.; Acobas, Jennifer K.; Phang, Ye Shang; Hassan, David; Bolton, Frank J.; Levitz, David

    2018-02-01

    Smartphones are currently used in many medical applications and are more frequently being integrated into medical imaging devices. The regulatory requirements in existence today however, particularly the standardization of smartphone imaging through validation and verification testing, only partially cover imaging characteristics with a smartphone. Specifically, it has been shown that smartphone camera specifications are of sufficient quality for medical imaging, and there are devices which comply with the FDA's regulatory requirements for a medical device such as a device's field of view, direction of viewing and optical resolution and optical distortion. However, these regulatory requirements do not call specifically for color testing. Images of the same object using automatic settings or different light sources can show different color composition. Experimental results showing such differences are presented. Under some circumstances, such differences in color composition could potentially lead to incorrect diagnoses. It is therefore critical to control the smartphone camera and illumination parameters properly. This paper examines different smartphone camera settings that affect image quality and color composition. To test and select the correct settings, a test methodology is proposed. It aims at evaluating and testing image color correctness and white balance settings for mobile phones and LED light sources. Emphasis is placed on color consistency and deviation from gray values, specifically by evaluating the ΔC values based on the CIEL*a*b* color space. Results show that such standardization minimizes differences in color composition and thus could reduce the risk of a wrong diagnosis.

  5. Innovative medical devices and hospital decision making: a study comparing the views of hospital pharmacists and physicians.

    Science.gov (United States)

    Billaux, Mathilde; Borget, Isabelle; Prognon, Patrice; Pineau, Judith; Martelli, Nicolas

    2016-06-01

    Objectives Many university hospitals have developed local health technology assessment processes to guide informed decisions about new medical devices. However, little is known about stakeholders' perceptions and assessment of innovative devices. Herein, we investigated the perceptions regarding innovative medical devices of their chief users (physicians and surgeons), as well as those of hospital pharmacists, because they are responsible for the purchase and management of sterile medical devices. We noted the evaluation criteria used to assess and select new medical devices and suggestions for improving local health technology assessment processes indicated by the interviewees. Methods We randomly selected 18 physicians and surgeons (nine each) and 18 hospital pharmacists from 18 French university hospitals. Semistructured interviews were conducted between October 2012 and August 2013. Responses were coded separately by two researchers. Results Physicians and surgeons frequently described innovative medical devices as 'new', 'safe' and 'effective', whereas hospital pharmacists focused more on economic considerations and considered real innovative devices to be those for which no equivalent could be found on the market. No significant difference in evaluation criteria was found between these groups of professionals. Finally, hospital pharmacists considered the management of conflicts of interests in local health technology assessment processes to be an issue, whereas physicians and surgeons did not. Conclusions The present study highlights differences in perceptions related to professional affiliation. The findings suggest several ways in which current practices for local health technology assessment in French university hospitals could be improved and studied. What is known about the topic? Hospitals are faced with ever-growing demands for innovative and costly medical devices. To help hospital management deal with technology acquisition issues, hospital

  6. Open-source hardware for medical devices.

    Science.gov (United States)

    Niezen, Gerrit; Eslambolchilar, Parisa; Thimbleby, Harold

    2016-04-01

    Open-source hardware is hardware whose design is made publicly available so anyone can study, modify, distribute, make and sell the design or the hardware based on that design. Some open-source hardware projects can potentially be used as active medical devices. The open-source approach offers a unique combination of advantages, including reducing costs and faster innovation. This article compares 10 of open-source healthcare projects in terms of how easy it is to obtain the required components and build the device.

  7. Modelling degradation of bioresorbable polymeric medical devices

    CERN Document Server

    Pan, J

    2015-01-01

    The use of bioresorbable polymers in stents, fixation devices and tissue engineering is revolutionising medicine. Both industry and academic researchers are interested in using computer modelling to replace some experiments which are costly and time consuming. This book provides readers with a comprehensive review of modelling polymers and polymeric medical devices as an alternative to practical experiments. Chapters in part one provide readers with an overview of the fundamentals of biodegradation. Part two looks at a wide range of degradation theories for bioresorbable polymers and devices.

  8. 77 FR 8260 - Agency Information Collection Activities; Proposed Collection; Comment Request; Medical Device...

    Science.gov (United States)

    2012-02-14

    ... will be used to evaluate risks associated with medical devices which will enable FDA to take...] Agency Information Collection Activities; Proposed Collection; Comment Request; Medical Device Reporting... comment in response to the notice. This notice solicits comments on medical device reporting (MDR...

  9. 77 FR 52742 - Public Meeting-Strengthening the National Medical Device Postmarket Surveillance System; Request...

    Science.gov (United States)

    2012-08-30

    ... Contact Person) no later than September 5, 2012. No commercial or promotional material will be permitted... develop and implement a comprehensive medical device postmarket surveillance strategy to collect, analyze... implementing this strategy, FDA is holding a public meeting to discuss the current and future state of medical...

  10. Development of formulation device for periodontal disease.

    Science.gov (United States)

    Sato, Yasuhiko; Oba, Takuma; Watanabe, Norio; Danjo, Kazumi

    2012-01-01

    In addition to providing standard surgical treatment that removes the plaque and infected tissues, medications that can regenerate periodontal tissue are also required in the treatment of periodontal disease. As a form of regenerative medication, various growth factors are expected to be used while treating periodontal disease. A protein-like growth factor is often developed as a lyophilized product with dissolution liquid, considering its instability in the solution state. We have clarified that the formulation for periodontal disease needs to be viscous. When the lyophilized product was dissolved using a sticky solution, various problems were encountered, difficulty in dissolving and air bubbles, for example, and some efforts were needed to prepare the formulation. In this research, to identify the problem of preparing a viscous formulation, a lyophilized product (placebo) and sticky liquid were prepared by using vial and ampoule as the conventional containers. Based on these problems, a prototype administration device was developed, and its functionality was confirmed. As a result, it was suggested that the device with a useful mixing system that could shorten the preparation time was developed.

  11. Home Use Devices: How to Prepare for and Handle Power Outages for Medical Devices That Require Electricity

    Science.gov (United States)

    ... to Create a Personal Emergency File My personal emergency file contains: □ Instructions for using the medical device and all device manuals. □ First aid kit □ Medical records □ Insurance cards □ Current home care doctor’s orders □ Plan of treatment □ What a family ...

  12. 76 FR 22322 - Medical Devices; Immunology and Microbiology Devices; Classification of Ovarian Adnexal Mass...

    Science.gov (United States)

    2011-04-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 866 [Docket No. FDA-2010-N-0026] Medical Devices; Immunology and Microbiology Devices; Classification of Ovarian Adnexal Mass Assessment Score Test System; Correction AGENCY: Food and Drug Administration, HHS. ACTION...

  13. Just a piece of equipment? The importance of medical device education.

    Science.gov (United States)

    Brand, Darren

    2012-12-01

    The use of medical devices is an increasingly important element of a healthcare professional's role. It is crucial that users receive regular teaching and education to ensure that they are competent in the use of devices. This is particularly relevant in the increasingly litigious society in which we live. This article focuses upon the importance of a medical device education.

  14. New IEEE 11073 Standards for interoperable, networked Point-of-Care Medical Devices.

    Science.gov (United States)

    Kasparick, Martin; Schlichting, Stefan; Golatowski, Frank; Timmermann, Dirk

    2015-08-01

    Surgical procedures become more and more complex and the number of medical devices in an operating room (OR) increases continuously. Today's vendor-dependent solutions for integrated ORs are not able to handle this complexity. They can only form isolated solutions. Furthermore, high costs are a result of vendor-dependent approaches. Thus we present a service-oriented device communication for distributed medical systems that enables the integration and interconnection between medical devices among each other and to (medical) information systems, including plug-and-play functionality. This system will improve patient's safety by making technical complexity of a comprehensive integration manageable. It will be available as open standards that are part of the IEEE 11073 family of standards. The solution consists of a service-oriented communication technology, the so called Medical Devices Profile for Web Services (MDPWS), a Domain Information & Service Model, and a binding between the first two mechanisms. A proof of this concept has been done with demonstrators of real world OR devices.

  15. Navigating conflicts of interest for the medical device entrepreneur.

    Science.gov (United States)

    Donovan, Aine; Kaplan, Aaron V

    2012-01-01

    The past fifty years has witnessed dramatic progress in the understanding and treatment of patients suffering from cardiovascular disease leading to symptomatic relief and impressive increases in longevity. These advances have been due in large part to the development, study and implementation of new technology. Within interventional cardiology in particular, these advances have been driven by the availability of new technology in the form of medical devices. Successful device development efforts require close collaboration among basic scientist, clinician-inventors/entrepreneurs, clinician-investigators and corporations. Though the role of the clinician is central to this process, these activities present important conflicts-of-interest (COIs). The purpose of this paper is to 1) characterize these conflicts, 2) provide a context from which to approach their management and 3) recommend management strategies. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. Hacking medical devices a review - biomed 2013.

    Science.gov (United States)

    Frenger, Paul

    2013-01-01

    Programmable, implantable and external biomedical devices (such as pacemakers, defibrillators, insulin pumps, pain management pumps, vagus nerve stimulators and others) may be vulnerable to unauthorized access, commonly referred to as “hacking”. This intrusion may lead to compromise of confidential patient data or loss of control of the device itself, which may be deadly. Risks to health from unauthorized access is in addition to hazards from faulty (“buggy”) software or circuitry. Historically, this aspect of medical device design has been underemphasized by both manufacturers and regulatory bodies until recently. However, an insulin pump was employed as a murder weapon in 2001 and successful hacking of an implantable defibrillator was demonstrated in 2008. To remedy these problems, professional groups have announced a variety of design standards and the governmental agencies of several countries have enacted device regulations. In turn, manufacturers have developed new software products and hardware circuits to assist biomedical engineering firms to improve their commercial offerings. In this paper the author discusses these issues, reviewing known problems and zero-day threats, with potential solutions. He outlines his approach to secure software and hardware challenges using the Forth language. A plausible scenario is described in which hacking of an implantable defibrillator by terrorists results in a severe national security threat to the United States.

  17. 21 CFR 892.2010 - Medical image storage device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical image storage device. 892.2010 Section 892.2010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED..., and digital memory. (b) Classification. Class I (general controls). The device is exempt from the...

  18. [Impact of an automated dispensing system for medical devices in cardiac surgery department].

    Science.gov (United States)

    Clou, E; Dompnier, M; Kably, B; Leplay, C; Poupon, E; Archer, V; Paul, M

    2018-01-01

    To secure medical devices' management, the implementation of automated dispensing system in surgical service has been realized. The objective of this study was to evaluate security, organizational and economic impact of installing automated dispensing system for medical devices (ASDM). The implementation took place in a cardiac surgery department. Security impact was assessed by comparing traceability rate of implantable medical devices one year before and one year after installation. Questionnaire on nurses' perception and satisfaction completed this survey. Resupplying costs, stocks' evolution and investments for the implementation of ASDM were the subject of cost-benefit study. After one year, traceability rate is excellent (100%). Nursing staffs were satisfied with 87.5% by this new system. The introduction of ASDM allowed a qualitative and quantitative decrease in stocks, with a reduction of 30% for purchased medical devices and 15% for implantable medical devices in deposit-consignment. Cost-benefit analysis shows a rapid return on investment. Real stock decrease (purchased medical devices) is equivalent to 46.6% of investment. Implementation of ASDM allows to secure storage and dispensing of medical devices. This system has also an important economic impact and appreciated by users. Copyright © 2017 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.

  19. [Regulatory Program for Medical Devices in Cuba: experiences and current challenges].

    Science.gov (United States)

    Pereira, Dulce María Martínez; Rodríguez, Yadira Álvarez; Valdés, Yamila Cedeño; Ribas, Silvia Delgado

    2016-05-01

    Regulatory control of medical devices in Cuba is conducted through a system based on the Regulatory Program for Medical Devices as a way to ensure the safety, efficacy, and effectiveness of these technologies, which are in use by the National Health System. This program was launched in 1992, when the Regulations for State Evaluation and Registration of Medical Devices were approved. Its successive stages and the merging of regulatory activities for drugs and medical equipment have meant progress toward stronger, more transparent strategies and greater control of industry and the National Health System. Throughout its course the Cuban program has met with challenges and difficulties that it has addressed by drawing on its own experiences. During the new period, the greatest challenges revolve around ensuring that regulatory systems incorporate scientific evaluation, risk levels, maximum rigor through the use of technical standards, and the implementation of international recommendations, together with the application of the ISO 13485 certification scheme, enhanced market monitoring, and classification of medical devices in accordance with their relevance to the country's national health policies. From the regional standpoint, the greatest challenge lies in working toward regulatory convergence. The Collaborating Centre for the Regulation of Health Technologies will support the proposed regulatory strategy and established regional priorities, in particular in connection with the implementation of actions involving medical devices.

  20. 76 FR 16292 - Medical Devices; Immunology and Microbiology Devices; Classification of Ovarian Adnexal Mass...

    Science.gov (United States)

    2011-03-23

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 866 [Docket No. FDA-2011-N-0026] Medical Devices; Immunology and Microbiology Devices; Classification of Ovarian... of Food and Drugs, 21 CFR part 866 is amended as follows: PART 866--IMMUNOLOGY AND MICROBIOLOGY...

  1. Virtual worlds are an innovative tool for medical device training in a simulated environment.

    Science.gov (United States)

    Patel, Vishal; Lee, Henry; Taylor, Dave; Aggarwal, Rajesh; Kinross, James; Darzi, Ara

    2012-01-01

    Medical infusion devices are an integral component within the delivery of healthcare management. The aim of this study was to develop a training simulation in the virtual world of Second Life for the management of adverse events associated with infusion devices. Forty nurses were subsequently recruited to participate within the simulation and assess its feasibility.

  2. Inhaled medication for asthma management: evaluation of how asthma patients, medical students, and doctors use the different devices

    Directory of Open Access Journals (Sweden)

    Muniz Janaína Barbosa

    2003-01-01

    Full Text Available Asthma results from a combination of three essential features: airflow obstruction, hyperresponsiveness of airways to endogenous or exogenous stimuli and inflammation. Inadequacy of the techniques to use different inhalation devices is one of the causes of therapeutic failure. The main purpose of this study was to evaluate how 20 medical students, 36 resident physicians of Internal Medicine/Pediatrics, and 40 asthma patients used three devices for inhalation therapy containing placebo. All patients were followed at the Pulmonary Outpatient Service of Botucatu Medical School and had been using inhaled medication for at least six months. The following devices were evaluated: metered dose inhalers (MDI, dry powder inhalers (DPI, and MDI attached to a spacer device. A single observer applied a protocol containing the main steps necessary to obtain a good inhaler technique to follow and grade the use of different devices. Health care professionals tested all three devices and patients tested only the device being used on their management. MDI was the device best known by doctors and patients. MDI use was associated with errors related to the coordination between inspiration and device activation. Failure to exhale completely before inhalation of the powder was the most frequent error observed with DPI use. In summary, patients did not receive precise instruction on how to use inhaled medication and health care professionals were not well prepared to adequately teach their patients.

  3. [Study on the reform and improvement of the medical device registration system in China].

    Science.gov (United States)

    Wang, Lanming

    2012-11-01

    Based on the theories of the Government Regulation and Administrative Licensure, aiming at the current situations of medical device registration system in China, some policy suggestions for future reform and improvement were provided as follows. (1) change the concepts of medical device registration administration. (2) perfect the regulations of medical device registration administration. (3) reform the medical device review organizational system. (4) Optimize the procedure of review and approval. (5) set up and maintain a professional team of review and approval staff. (6) reinforce the post-marketing supervision of medical devices. (7) foster and bring into play of the role of non-government organizations.

  4. [Study on restriction factors and countermeasures of influence of China medical devices competitiveness].

    Science.gov (United States)

    Zhang, Zhijun

    2012-07-01

    Recent years, China medical devices industry has been a sunrise industry with widely-ranged products, high-tech innovation, and booming market demands. But with the globalization of market economy, China industry is still in the inferior position of competition. How to promote the industrial structure transition, increase scientific and technological level, speed up the updating of products, enhance the international competitiveness is one of the major tasks to maintain the healthy development of industry. This article makes a study on current situation of China medical devices industry, analyses the new opportunities, challenges and restriction factors, provides the countermeasures of strengthening industry competitiveness as well.

  5. The future of the pharmaceutical, biological and medical device industry

    Directory of Open Access Journals (Sweden)

    Burgess LJ

    2011-09-01

    Full Text Available Lesley J Burgess, Marli TerblancheTREAD Research/Cardiology Unit, Department of Internal Medicine, Tygerberg Hospital and University of Stellenbosch, Parow, South AfricaAbstract: Numerous factors contribute to the declining pharmaceutical industry on the one hand and the rapidly growing generic industry together with the growing importance of medical devices and biologicals on the other. It is clear that the pharmaceutical industry is going to undergo a change in the next decade in order to meet the current challenges facing it and ultimately sustain its profitability and growth. This paper aims to identify a number of fairly obvious trends that are likely to have a significant impact on the product development pipeline in the next decade. It is more than clear that the current production pipeline for pharmaceutical, biotechnology and medical device industries is no longer sustainable and that urgent interventions are required in order to maintain its current level of profitability.Keywords: pharmaceutical industry, personalized medicine, trends, generics, biotechnology

  6. 75 FR 70112 - Medical Devices; General and Plastic Surgery Devices; Classification of Non-Powered Suction...

    Science.gov (United States)

    2010-11-17

    .... FDA-2010-N-0513] Medical Devices; General and Plastic Surgery Devices; Classification of Non-Powered... risks. Adverse tissue reaction Material degradation Improper function of suction apparatus (e.g., reflux.... Material degradation Section 8. Stability and Shelf Life. [[Page 70113

  7. Campaign to gather medical devices containing radium: results

    International Nuclear Information System (INIS)

    Pierre, J.P.; Vidal, J.P.; Martin, J.C.; Pasquier, J.L.

    2002-01-01

    Campaign to gather medical devices containing radium: results. On December 1, 1999, at the request of the French Health Ministry, OPRI and ANDRA launched a campaign to gather medical devices containing radium, formerly used in brachytherapy. This campaign addressed a public health issue because of the risks actually involved in a careless handling of these objects. Moreover the growing number of reported scattered radium medical devices in the last few years reinforced the necessity of the campaign. The gathering was initiated by a call of the owners (hospitals, caring centers, retired doctors or their heirs) to a toll free number. OPRI or ANDRA then appreciated the situation urgency. Priority was given to private people because most of them did not have suitable storage facilities. OPRI teams operated according a strict protocol guaranteeing their own safety, proper procedures and compliance with transport regulations for radioactive materials. 517 objects amounting to an activity of 1.32 x 10 11 Bq have been gathered in 90 operations. Properly packaged they were transported to and safely stored at the CEA Saclay site before their permanent storage in the ANDRA facilities. (author)

  8. Characterization of Bacterial Etiologic Agents of Biofilm Formation in Medical Devices in Critical Care Setup

    Directory of Open Access Journals (Sweden)

    Sangita Revdiwala

    2012-01-01

    Full Text Available Background. Biofilms contaminate catheters, ventilators, and medical implants; they act as a source of disease for humans, animals, and plants. Aim. Critical care units of any healthcare institute follow various interventional strategies with use of medical devices for the management of critical cases. Bacteria contaminate medical devices and form biofilms. Material and Methods. The study was carried out on 100 positive bacteriological cultures of medical devices which were inserted in hospitalized patients. The bacterial isolates were processed as per microtitre plate. All the isolates were subjected to antibiotic susceptibility testing by VITEK 2 compact automated systems. Results. Out of the total 100 bacterial isolates tested, 88 of them were biofilm formers. A 16–20-hour incubation period was found to be optimum for biofilm development. 85% isolates were multidrug resistants and different mechanisms of bacterial drug resistance like ESBL, carbapenemase, and MRSA were found among isolates. Conclusion. Availability of nutrition in the form of glucose enhances the biofilm formation by bacteria. Time and availability of glucose are important factors for assessment of biofilm progress. It is an alarm for those who are associated with invasive procedures and indwelling medical devices especially in patients with low immunity.

  9. Drugs and Medical Devices: Adverse Events and the Impact on Women's Health.

    Science.gov (United States)

    Carey, Jennifer L; Nader, Nathalie; Chai, Peter R; Carreiro, Stephanie; Griswold, Matthew K; Boyle, Katherine L

    2017-01-01

    A large number of medications and medical devices removed from the market by the US Food and Drug Administration over the past 4 decades specifically posed greater health risks to women. This article reviews the historical background of sex and gender in clinical research policy and describes several approved drugs and devices targeted for use in women that have caused major morbidity and mortality. The intended population for the medications and devices, population affected, approval process, and the basic and legal actions taken against the medication/drug company are also discussed. It is recognized that women are still at risk for harm from unsafe medications and devices, and continued improvements in legislation that promotes inclusion of sex and gender into the design and analysis of research will improve safety for both men and women. Copyright © 2017 Elsevier HS Journals, Inc. All rights reserved.

  10. 76 FR 71982 - Advancing Regulatory Science for Highly Multiplexed Microbiology/Medical Countermeasure Devices...

    Science.gov (United States)

    2011-11-21

    ... Multiplexed Microbiology Devices: Their clinical application and public health/clinical needs; inclusion of...] Advancing Regulatory Science for Highly Multiplexed Microbiology/ Medical Countermeasure Devices; Public... Multiplexed Microbiology/ Medical Countermeasure Devices'' that published in the Federal Register of August 8...

  11. Electromagnetic compatibility of WLAN adapters with life-supporting medical devices.

    Science.gov (United States)

    Calcagnini, G; Mattei, E; Censi, F; Triventi, M; Lo Sterzo, R; Marchetta, E; Bartolini, P

    2011-05-01

    This paper investigates the electromagnetic compatibility of 45 critical care medical devices (infusion pumps, defibrillators, monitors, lung ventilators, anesthesia machines and external pacemakers) with various types of wireless local area network (WLAN, IEEE 802.11 b/g, 2.45 GHz, 100 mW) adapters. Interference is evaluated by performing ad-hoc tests according to the ANSI C63.18 recommended practice. The behavior of the devices during the tests was monitored using patient simulators/device testers specific for each device class. Electromagnetic interference cases were observed in three of 45 devices at a maximum distance of 5 cm. In two cases the interference caused malfunctions that may have clinical consequences for the patient. The authors' findings show that the use of these wireless local area network adapters can be considered reasonably safe, although interference may occur if they are operated at very close distance (<10 cm) to the medical devices.

  12. 77 FR 6028 - Taxable Medical Devices

    Science.gov (United States)

    2012-02-07

    ... sold as part of an x-ray system. Commentators also requested information on the tax treatment of..., mitigation, treatment, or prevention of disease; or intended to affect the structure or any function of the... subject to an IDE is not a ``taxable medical device'' under the proposed regulations. VI. Dental...

  13. 78 FR 33849 - Battery-Powered Medical Devices Workshop: Challenges and Opportunities; Public Workshop; Request...

    Science.gov (United States)

    2013-06-05

    ... after the public workshop on the Internet at http://www.fda.gov/MedicalDevices/NewsEvents/Workshops..., compact, and mobile, the number of battery-powered medical devices will continue to increase. While many...] Battery-Powered Medical Devices Workshop: Challenges and Opportunities; Public Workshop; Request for...

  14. 75 FR 68972 - Medical Devices; General and Plastic Surgery Devices; Classification of Tissue Adhesive With...

    Science.gov (United States)

    2010-11-10

    .... FDA-2010-N-0512] Medical Devices; General and Plastic Surgery Devices; Classification of Tissue... running to unintended areas, etc. B. Wound dehiscence C. Adverse tissue reaction and chemical burns D..., Clinical Studies, Labeling. Adverse tissue reaction and chemical Biocompatibility Animal burns. Testing...

  15. 77 FR 32644 - Medical Devices; Exemption From Premarket Notification: Wheelchair Elevator

    Science.gov (United States)

    2012-06-01

    ...] Medical Devices; Exemption From Premarket Notification: Wheelchair Elevator AGENCY: Food and Drug... elevator devices commonly known as inclined platform lifts and vertical platform lifts. These devices are... behalf of Bruno Independent Living Aids, Inc., for wheelchair elevator devices (commonly known as...

  16. Views of patients and professionals about electronic multicompartment medication devices: a qualitative study.

    Science.gov (United States)

    Hall, Jill; Bond, Christine; Kinnear, Moira; McKinstry, Brian

    2016-10-17

    To explore the perceived acceptability, advantages and disadvantages of electronic multicompartment medication devices. Qualitative study using 8 focus groups and 10 individual semistructured interviews. Recordings were transcribed and analysed thematically. Strategies were employed to ensure the findings were credible and trustworthy. Community pharmacists (n=11), general practitioners (n=9), community nurses (n=12) and social care managers (n=8) were recruited from the National Health Service (NHS) and local authority services. Patients (n=15) who were current conventional or electronic multicompartment medication device users or had medication adherence problems were recruited from community pharmacies. 3 informal carers participated. Electronic multicompartment medication devices which prompt the patient to take medication may be beneficial for selected individuals, particularly those with cognitive impairment, but who are not seriously impaired, provided they have a good level of dexterity. They may also assist individuals where it is important that medication is taken at fixed time intervals. These are likely to be people who are being supported to live alone. No single device suited everybody; smaller/lighter devices were preferred but their usefulness was limited by the small number/size of storage compartments. Removing medications was often challenging. Transportability was an important factor for patients and carers. A carer's alert if medication is not taken was problematic with multiple barriers to implementation and no consensus as to who should receive the alert. There was a lack of enthusiasm among professionals, particularly among pharmacists, due to concerns about responsibility and funding for devices as well as ensuring devices met regulatory standards for storage and labelling. This study provides indicators of which patients might benefit from an electronic multicompartment medication device as well as the kinds of features to consider when

  17. Study on 3D printer production of auxiliary device for upper limb for medical imaging test

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyeong Gyun [Dept. of Radiological Science, Far East University, Eumsung (Korea, Republic of); Yoon, Jae Ho [Jukwang Precision Co., Ltd., Gumi (Korea, Republic of); Choi, Seong Dae [Dept. of Mechanical system engineering, Kumoh Institute of Technology, Gumi (Korea, Republic of)

    2015-12-15

    There is a progressive development in the medical imaging technology, especially of descriptive capability for anatomical structure of human body thanks to advancement of information technology and medical devices. But however maintenance of correct posture is essential for the medical imaging checkup on the shoulder joint requiring rotation of the upper limb due to the complexity of human body. In the cases of MRI examination, long duration and fixed posture are critical, as failure to comply with them leads to minimal possibility of reproducibility only with the efforts of the examiner and will of the patient. Thus, this study aimed to develop an auxiliary device that enables rotation of the upper limb as well as fixing it at quantitative angles for medical imaging examination capable of providing diagnostic values. An auxiliary device has been developed based on the results of precedent studies, by designing a 3D model with the CATIA software, an engineering application, and producing it with the 3D printer. The printer is Objet350 Connex from Stratasys, and acrylonitrile- butadiene-styrene(ABS) is used as the material of the device. Dimensions are 120 X 150 X 190 mm, with the inner diameter of the handle being 125.9 mm. The auxiliary device has 4 components including the body (outside), handle (inside), fixture terminal and the connection part. The body and handle have the gap of 2.1 mm for smooth rotation, while the 360 degree of scales have been etched on the handle so that the angle required for observation may be recorded per patient for traceability and dual examination.

  18. Study on 3D printer production of auxiliary device for upper limb for medical imaging test

    International Nuclear Information System (INIS)

    Kim, Hyeong Gyun; Yoon, Jae Ho; Choi, Seong Dae

    2015-01-01

    There is a progressive development in the medical imaging technology, especially of descriptive capability for anatomical structure of human body thanks to advancement of information technology and medical devices. But however maintenance of correct posture is essential for the medical imaging checkup on the shoulder joint requiring rotation of the upper limb due to the complexity of human body. In the cases of MRI examination, long duration and fixed posture are critical, as failure to comply with them leads to minimal possibility of reproducibility only with the efforts of the examiner and will of the patient. Thus, this study aimed to develop an auxiliary device that enables rotation of the upper limb as well as fixing it at quantitative angles for medical imaging examination capable of providing diagnostic values. An auxiliary device has been developed based on the results of precedent studies, by designing a 3D model with the CATIA software, an engineering application, and producing it with the 3D printer. The printer is Objet350 Connex from Stratasys, and acrylonitrile- butadiene-styrene(ABS) is used as the material of the device. Dimensions are 120 X 150 X 190 mm, with the inner diameter of the handle being 125.9 mm. The auxiliary device has 4 components including the body (outside), handle (inside), fixture terminal and the connection part. The body and handle have the gap of 2.1 mm for smooth rotation, while the 360 degree of scales have been etched on the handle so that the angle required for observation may be recorded per patient for traceability and dual examination

  19. Left to their own devices: medical learners' use of mobile technologies.

    Science.gov (United States)

    Ellaway, Rachel H; Fink, Patricia; Graves, Lisa; Campbell, Alanna

    2014-02-01

    Although many medical learners and teachers are using mobile technologies within medical education, there has been little evidence presented describing how they use mobile devices across a whole curriculum. The Northern Ontario School of Medicine (NOSM) introduced a new mobile device program in 2010. Incoming undergraduate medical learners received a laptop and an iPad and learners entering year three of the four-year program received a laptop and an iPhone. A survey was sent to all learners to gather information on their use of and attitudes toward these devices. A combination of quantitative and qualitative methods was used to analyze the data and to generate a series of themes that synthesized student behaviors, perceptions and attitudes. Context and learner autonomy were found to be important factors with learners using multiple devices for different purposes and adopting strategic approaches to learning using these devices. The expectation that school-issued devices would be regularly and enthusiastically used to replace more traditional study media was not reflected in practice. Learners' approaches to using mobile devices are heterogeneous as is the extent to which they use them. Learners adapt their use of mobile devices to the learning cultures and contexts they find themselves in.

  20. Advancing medical device innovation through collaboration and coordination of structured data capture pilots: Report from the Medical Device Epidemiology Network (MDEpiNet) Specific, Measurable, Achievable, Results-Oriented, Time Bound (SMART) Think Tank.

    Science.gov (United States)

    Reed, Terrie L; Drozda, Joseph P; Baskin, Kevin M; Tcheng, James; Conway, Karen; Wilson, Natalia; Marinac-Dabic, Danica; Heise, Theodore; Krucoff, Mitchell W

    2017-12-01

    The Medical Device Epidemiology Network (MDEpiNet) is a public private partnership (PPP) that provides a platform for collaboration on medical device evaluation and depth of expertise for supporting pilots to capture, exchange and use device information for improving device safety and protecting public health. The MDEpiNet SMART Think Tank, held in February, 2013, sought to engage expert stakeholders who were committed to improving the capture of device data, including Unique Device Identification (UDI), in key electronic health information. Prior to the Think Tank there was limited collaboration among stakeholders beyond a few single health care organizations engaged in electronic capture and exchange of device data. The Think Tank resulted in what has become two sustainable multi-stakeholder device data capture initiatives, BUILD and VANGUARD. These initiatives continue to mature within the MDEpiNet PPP structure and are well aligned with the goals outlined in recent FDA-initiated National Medical Device Planning Board and Medical Device Registry Task Force white papers as well as the vision for the National Evaluation System for health Technology.%. Published by Elsevier Inc.

  1. Cost effectiveness of medical devices to diagnose pre-eclampsia in low-resource settings

    Directory of Open Access Journals (Sweden)

    Zoë M. McLaren

    Full Text Available Background: Maternal mortality remains a major health challenge facing developing countries, with pre-eclampsia accounting for up to 17% of maternal deaths. Diagnosis requires skilled health providers and devices that are appropriate for low-resource settings. This study presents the first cost-effectiveness analysis of multiple medical devices used to diagnose pre-eclampsia in low- and middle-income countries (LMICs. Methods: Blood pressure and proteinuria measurement devices, identified from compendia for LMICs, were included. We developed a decision tree framework to assess the cost-effectiveness of each device using parameter values that reflect the general standard of care based on a survey of relevant literature and expert opinion. We examined the sensitivity of our results using one-way and second-order probabilistic multivariate analyses. Results: Because the disability-adjusted life years (DALYs averted for each device were very similar, the results were influenced by the per-use cost ranking. The most cost-effective device combination was a semi-automatic blood pressure measurement device and visually read urine strip test with the lowest combined per-use cost of $0.2004 and an incremental cost effectiveness ratio of $93.6 per DALY gained relative to a baseline with no access to diagnostic devices. When access to treatment is limited, it is more cost-effective to improve access to treatment than to increase testing rates or diagnostic device sensitivity. Conclusions: Our findings were not sensitive to changes in device sensitivity, however they were sensitive to changes in the testing rate and treatment rate. Furthermore, our results suggest that simple devices are more cost-effective than complex devices. The results underscore the desirability of two design features for LMICs: ease of use and accuracy without calibration. Our findings have important implications for policy makers, health economists, health care providers and

  2. Possibilities of radiation sterilization for re-usage of medical devices in the medical management

    International Nuclear Information System (INIS)

    Tabei, Masae; Kudo, Hisaaki; Katsumura, Yosuke

    2004-01-01

    The rule for re-usage of medical single-use devices was established in US in 2000 based on the concept of Managed Care (total management of medicare on cost, quality and patients' satisfaction) and 20-30% of those devices are re-used at present. The re-usage is conducted in not only US but also Canada, Denmark, UK, India, China etc. Standing on the viewpoint, this paper described and discussed the possibility of re-usage of the single-use devices now prohibited in Japan, possible re-sterilization, possible re-usage of hollow fiber-type hemodialyzer following γ-ray sterilization with consideration for D-values against bacteria and viruses, cost estimation of electron beam sterilization for re-usage, and radiation sterilization of waste water and plastic materials. Radiation sterilization for re-usage of medical devices was concluded possible if their materials and records for their usage processes are proper, and should be conducted in a large scale after sufficient examinations by industries/government/academia. (N.I.)

  3. Third-year medical students' knowledge of privacy and security issues concerning mobile devices.

    Science.gov (United States)

    Whipple, Elizabeth C; Allgood, Kacy L; Larue, Elizabeth M

    2012-01-01

    The use of mobile devices are ubiquitous in medical-care professional settings, but information on privacy and security concerns of mobile devices for medical students is scarce. To gain baseline information about third-year medical students' mobile device use and knowledge of privacy and security issues concerning mobile devices. We surveyed 67 third-year medical students at a Midwestern university on their use of mobile devices and knowledge of how to protect information available through mobile devices. Students were also presented with clinical scenarios to rate their level of concern in regards to privacy and security of information. The most used features of mobile devices were: voice-to-voice (100%), text messaging (SMS) (94%), Internet (76.9%), and email (69.3%). For locking of one's personal mobile phone, 54.1% never physically lock their phone, and 58% never electronically lock their personal PDA. Scenarios considering definitely privacy concerns include emailing patient information intact (66.7%), and posting de-identified information on YouTube (45.2%) or Facebook (42.2%). As the ease of sharing data increases with the use of mobile devices, students need more education and training on possible privacy and security risks posed with mobile devices.

  4. Low power signal processing electronics for wearable medical devices.

    Science.gov (United States)

    Casson, Alexander J; Rodriguez-Villegas, Esther

    2010-01-01

    Custom designed microchips, known as Application Specific Integrated Circuits (ASICs), offer the lowest possible power consumption electronics. However, this comes at the cost of a longer, more complex and more costly design process compared to one using generic, off-the-shelf components. Nevertheless, their use is essential in future truly wearable medical devices that must operate for long periods of time from physically small, energy limited batteries. This presentation will demonstrate the state-of-the-art in ASIC technology for providing online signal processing for use in these wearable medical devices.

  5. Improving Patient Safety with X-Ray and Anesthesia Machine Ventilator Synchronization: A Medical Device Interoperability Case Study

    Science.gov (United States)

    Arney, David; Goldman, Julian M.; Whitehead, Susan F.; Lee, Insup

    When a x-ray image is needed during surgery, clinicians may stop the anesthesia machine ventilator while the exposure is made. If the ventilator is not restarted promptly, the patient may experience severe complications. This paper explores the interconnection of a ventilator and simulated x-ray into a prototype plug-and-play medical device system. This work assists ongoing interoperability framework development standards efforts to develop functional and non-functional requirements and illustrates the potential patient safety benefits of interoperable medical device systems by implementing a solution to a clinical use case requiring interoperability.

  6. Stakeholder challenges in purchasing medical devices for patient safety.

    Science.gov (United States)

    Hinrichs, Saba; Dickerson, Terry; Clarkson, John

    2013-03-01

    This study identifies the stakeholders who have a role in medical device purchasing within the wider system of health-care delivery and reports on their particular challenges to promote patient safety during purchasing decisions. Data was collected through observational work, participatory workshops, and semi-structured qualitative interviews, which were analyzed and coded. The study takes a systems-based and engineering design approach to the study. Five hospitals took part in this study, and the participants included maintenance, training, clinical end-users, finance, and risk departments. The main stakeholders for purchasing were identified to be staff from clinical engineering (Maintenance), device users (Clinical), device trainers (Training), and clinical governance for analyzing incidents involving devices (Risk). These stakeholders display varied characteristics in terms of interpretation of their own roles, competencies for selecting devices, awareness and use of resources for purchasing devices, and attitudes toward the purchasing process. The role of "clinical engineering" is seen by these stakeholders to be critical in mediating between training, technical, and financial stakeholders but not always recognized in practice. The findings show that many device purchasing decisions are tackled in isolation, which is not optimal for decisions requiring knowledge that is currently distributed among different people within different departments. The challenges expressed relate to the wider system of care and equipment management, calling for a more systemic view of purchasing for medical devices.

  7. How does the knowledge environment shape procurement practices for orthopaedic medical devices in Mexico?

    Science.gov (United States)

    Lingg, Myriam; Wyss, Kaspar; Durán-Arenas, Luis

    2016-07-08

    In organisational theory there is an assumption that knowledge is used effectively in healthcare systems that perform well. Actors in healthcare systems focus on managing knowledge of clinical processes like, for example, clinical decision-making to improve patient care. We know little about connecting that knowledge to administrative processes like high-risk medical device procurement. We analysed knowledge-related factors that influence procurement and clinical procedures for orthopaedic medical devices in Mexico. We based our qualitative study on 48 semi-structured interviews with various stakeholders in Mexico: orthopaedic specialists, government officials, and social security system managers or administrators. We took a knowledge-management related perspective (i) to analyse factors of managing knowledge of clinical procedures, (ii) to assess the role of this knowledge and in relation to procurement of orthopaedic medical devices, and (iii) to determine how to improve the situation. The results of this study are primarily relevant for Mexico but may also give impulsion to other health systems with highly standardized procurement practices. We found that knowledge of clinical procedures in orthopaedics is generated inconsistently and not always efficiently managed. Its support for procuring orthopaedic medical devices is insufficient. Identified deficiencies: leaders who lack guidance and direction and thus use knowledge poorly; failure to share knowledge; insufficiently defined formal structures and processes for collecting information and making it available to actors of health system; lack of strategies to benefit from synergies created by information and knowledge exchange. Many factors are related directly or indirectly to technological aspects, which are insufficiently developed. The content of this manuscript is novel as it analyses knowledge-related factors that influence procurement of orthopaedic medical devices in Mexico. Based on our results we

  8. [Software as medical devices/medical apps : Tasks, requirements, and experiences from the point of view of a competent authority].

    Science.gov (United States)

    Terhechte, Arno

    2018-03-01

    Software can be classified as a medical device according to the Medical Device Directive 93/42/EEC. The number of software products and medical apps is continuously increasing and so too is the use in health institutions (e. g., in hospitals and doctors' surgeries) for diagnosis and therapy.Different aspects of standalone software and medical apps from the perspective of the authority responsible are presented. The quality system implemented to establish a risk-based systematic inspection and supervision of manufacturers is discussed. The legal framework, as well as additional standards that are the basis for inspection, are outlined. The article highlights special aspects that occur during inspection like verification of software and interfaces, and the clinical evaluation of software. The Bezirksregierung, as the local government authority responsible in North Rhine-Westphalia, is also in charge of inspection of health institutions. Therefore this article is not limited to the manufacturers placing the software on the market, but in addition it describes the management and use of software as a medical device in hospitals.The future legal framework, the Medical Device Regulation, will strengthen the requirements and engage notified bodies more than today in the conformity assessment of software as a medical device.Manufacturers, health institutions, notified bodies and the authorities responsible are in charge of intensifying their efforts towards software as a medical device. Mutual information, improvement of skills, and inspections will lead to compliance with regulatory requirements.

  9. Research on dose setting for radiation sterilization of medical device

    International Nuclear Information System (INIS)

    Zhang Tongcheng; Liu Qingfang; Zhong Hongliang; Mi Zhisu; Wang Chunlei; Jiang Jianping

    2002-01-01

    Objective: To establish the radiation sterilization dose for medical devices using data of bioburden on the medical device. Methods: Firstly determination of recovery ratio and correction coefficient of the microbiological test method was used according to ISO11737 standard, then determination of bioburden on the products, finally the dose setting was completed based on the Method 1 in ISO11137 standard. Results: Fifteen kinds of medical devices were tested. Bioburden range was from 8.6-97271.2 CFU/device, recovery ration range 54.6%-100%, correction co-efficiency range 1.00-1.83, D 10 distribution from 1.40 to 2.82 kGy, verification dose (dose at SAL = 10 -2 ) range 5.1-17.6 kGy and sterilization dose (dose at SAL 10 -6 ) range 17.5-32.5 kGy. Conclusion: One hundred samples of each kind of product were exposed to the pre-determined verification dose and then the sterility test was performed. Each sterility test showed positive number was not greater than two. This indicated that the sterilization dose established for each kind of product was statistically acceptable

  10. 77 FR 32642 - Medical Devices; Exemption From Premarket Notification: Powered Patient Transport

    Science.gov (United States)

    2012-06-01

    ...] Medical Devices; Exemption From Premarket Notification: Powered Patient Transport AGENCY: Food and Drug... received a petition requesting exemption from the premarket notification requirements for powered patient... necessary to provide a reasonable assurance of safety and effectiveness. Under the Medical Device Amendments...

  11. 76 FR 14414 - Microbiology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2011-03-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES [Docket No. FDA-2011-N-0002] Microbiology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and Drug Administration, HHS... and Drug Administration (FDA). The meeting will be open to the public. Name of Committee: Microbiology...

  12. Relative risk analysis in regulating the use of radiation-emitting medical devices. A preliminary application

    Energy Technology Data Exchange (ETDEWEB)

    Jones, E.D.; Banks, W.W.; Altenbach, T.J.; Fischer, L.E. [Lawrence Livermore National Lab., CA (United States)

    1995-09-01

    This report describes a preliminary application of an analysis approach for assessing relative risks in the use of radiation- emitting medical devices. Results are presented on human-initiated actions and failure modes that are most likely to occur in the use of the Gamma Knife, a gamma irradiation therapy device. This effort represents an initial step in a US Nuclear Regulatory Commission (NRC) plan to evaluate the potential role of risk analysis in regulating the use of nuclear medical devices. For this preliminary application of risk assessment, the focus was to develop a basic process using existing techniques for identifying the most likely risk contributors and their relative importance. The approach taken developed relative risk rankings and profiles that incorporated the type and quality of data available and could present results in an easily understood form. This work was performed by the Lawrence Livermore National Laboratory for the NRC.

  13. Relative risk analysis in regulating the use of radiation-emitting medical devices. A preliminary application

    International Nuclear Information System (INIS)

    Jones, E.D.; Banks, W.W.; Altenbach, T.J.; Fischer, L.E.

    1995-09-01

    This report describes a preliminary application of an analysis approach for assessing relative risks in the use of radiation- emitting medical devices. Results are presented on human-initiated actions and failure modes that are most likely to occur in the use of the Gamma Knife, a gamma irradiation therapy device. This effort represents an initial step in a US Nuclear Regulatory Commission (NRC) plan to evaluate the potential role of risk analysis in regulating the use of nuclear medical devices. For this preliminary application of risk assessment, the focus was to develop a basic process using existing techniques for identifying the most likely risk contributors and their relative importance. The approach taken developed relative risk rankings and profiles that incorporated the type and quality of data available and could present results in an easily understood form. This work was performed by the Lawrence Livermore National Laboratory for the NRC

  14. Medical Device Plug-and-Play Interoperability Standards and Technology Leadership

    Science.gov (United States)

    2010-10-01

    American Telemedicine Association), we demonstrated how continuous monitoring of the patient’s SpO2 and respiratory rate could detect the onset of...designed to monitor sepsis infection sounded its alarm continually, day and night. The device was built with an innovative algorithm to detect sepsis, but...transport Figure 3. This medical device has misread its sensors and inserted false data into patient’s permanent medical record. SPECIal FEaTuRE October

  15. 21 CFR 801.16 - Medical devices; Spanish-language version of certain required statements.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical devices; Spanish-language version of....16 Medical devices; Spanish-language version of certain required statements. If devices restricted to prescription use only are labeled solely in Spanish for distribution in the Commonwealth of Puerto Rico where...

  16. High-Confidence Medical Devices: Cyber-Physical Systems for 21st Century Health Care

    Data.gov (United States)

    Networking and Information Technology Research and Development, Executive Office of the President — The U.S. market for medical devices is the largest in the world. At an estimated $83 billion in 2006, this market represents nearly half the global total and is...

  17. 31 CFR 595.513 - In-kind donations of medicine, medical devices, and medical services.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false In-kind donations of medicine...-kind donations of medicine, medical devices, and medical services. (a) Effective July 6, 2006, nongovernmental organizations that are U.S. persons are authorized to provide in-kind donations of medicine...

  18. Pricing and reimbursement of drugs and medical devices in Hungary.

    Science.gov (United States)

    Gulácsi, L; Dávid, T; Dózsa, Cs

    2002-01-01

    Similarly to other countries of Central and Eastern Europe, Hungary has witnessed massive diffusion of healthcare technology such as drugs and medical devices since 1990. While substantial new pharmaceuticals, medical devices, and procedures have been liberalized, there has been no proper evaluation or training in their use. Healthcare providers have come to find themselves as entrepreneurs in private practice, while patients are acquiring an increasing awareness as customers of healthcare,demanding services in return for their taxes and contributions. This has led to extremely irrational patterns of investment in technology, with most an obvious waste of resources, while leaving basic needs unmet. Both the National Health Insurance Fund and the Ministry of Finance believe that the current pharmaceutical and medical device bill is too high. However, introducing a more transparent and flexible pricing and reimbursement framework may enable a more efficient allocation of the limited resources to be achieved.

  19. 75 FR 1395 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of...

    Science.gov (United States)

    2010-01-11

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2009-N-0606] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of Notice...) is announcing an amendment to the notice of a meeting of the General and Plastic Surgery Devices...

  20. Challenges in the Assessment of Medical Devices: The MedtecHTA Project.

    Science.gov (United States)

    Tarricone, Rosanna; Torbica, Aleksandra; Drummond, Michael

    2017-02-01

    Assessing medical devices (MDs) raises challenges which require us to reflect on whether current methods are adequate. Major features of devices are: (i) device-operator interaction can generate learning curve effects; (ii) incremental nature of innovation needs to be addressed by careful identification of the alternatives for comparative and incremental cost-effectiveness analysis; and (iii) broader organizational impact in terms of training and infrastructure, coupled with dynamic pricing, requires a more flexible approach to costing. The objective of the MedtecHTA project was to investigate improvements in HTA methods to allow for more comprehensive evaluation of MDs. It consisted of several work packages concerning (i) the available evidence on the currently adopted approaches for regulation and HTA of medical devices; (ii) the geographical variation in access to MDs; (iii) the development of methodological frameworks for conducting comparative effectiveness research and economic evaluation of MDs; and (iv) the organizational impact of MDs. This introductory paper summarizes the main results of the project and draws out the main overarching themes. This supplement represents a comprehensive report of all the main findings of the MedtecHTA project, and it is intended to be the main source for researchers and policy makers wanting information on the project. © 2017 The Authors. Health Economics published by John Wiley & Sons, Ltd. © 2017 The Authors. Health Economics Published by John Wiley & Sons, Ltd.

  1. Towards automated assistance for operating home medical devices.

    Science.gov (United States)

    Gao, Zan; Detyniecki, Marcin; Chen, Ming-Yu; Wu, Wen; Hauptmann, Alexander G; Wactlar, Howard D

    2010-01-01

    To detect errors when subjects operate a home medical device, we observe them with multiple cameras. We then perform action recognition with a robust approach to recognize action information based on explicitly encoding motion information. This algorithm detects interest points and encodes not only their local appearance but also explicitly models local motion. Our goal is to recognize individual human actions in the operations of a home medical device to see if the patient has correctly performed the required actions in the prescribed sequence. Using a specific infusion pump as a test case, requiring 22 operation steps from 6 action classes, our best classifier selects high likelihood action estimates from 4 available cameras, to obtain an average class recognition rate of 69%.

  2. 31 CFR 594.515 - In-kind donations of medicine, medical devices, and medical services.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false In-kind donations of medicine....515 In-kind donations of medicine, medical devices, and medical services. (a) Effective July 6, 2006, nongovernmental organizations that are U.S. persons are authorized to provide in-kind donations of medicine...

  3. 31 CFR 597.511 - In-kind donations of medicine, medical devices, and medical services.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false In-kind donations of medicine... Licensing Policy § 597.511 In-kind donations of medicine, medical devices, and medical services. (a... incident to the provision by nongovernmental organizations that are U.S. persons of in-kind donations of...

  4. ANSTO and CSIRO: supporting the medical devices and sensors industry in Australia

    International Nuclear Information System (INIS)

    Triani, Gerry; Doe, Simon

    2005-01-01

    The Australian Nuclear Science and Technology Organisation (ANSTO) and the Commonwealth Scientific and Industrial Research Organisation (CSIRO) have provided support to the Medical Devices and Sensors Industry in Australia for many years. In particular the Institute of Materials and Engineering Science at ANSTO and CSIRO Manufacturing and Infrastructure Technology have worked independently and jointly on a number of projects to provide technical services and support to small to medium sized companies. A recent venture to capture their capabilities in the WTIA's Medical Devices and Sensors Industry Sectoral Project, part of the WTIA National Diffusion Networks Project, has produced substantial technical and financial gains for its participants. The aim of this article is to highlight the infrastructure and capabilities that ANSTO and CSIRO can provide to component manufacturers and industry clusters that offer a range of manufacturing processes needed for medical devices and sensors. Several case studies illustrate how ANSTO and CSIRO have provided support to the medical devices industry

  5. Assurance of Medical Device Quality with Quality Management System: An Analysis of Good Manufacturing Practice Implementation in Taiwan

    Directory of Open Access Journals (Sweden)

    Tzu-Wei Li

    2015-01-01

    Full Text Available The implementation of an effective quality management system has always been considered a principal method for a manufacturer to maintain and improve its product and service quality. Globally many regulatory authorities incorporate quality management system as one of the mandatory requirements for the regulatory control of high-risk medical devices. The present study aims to analyze the GMP enforcement experience in Taiwan between 1998 and 2013. It describes the regulatory implementation of medical device GMP requirement and initiatives taken to assist small and medium-sized enterprises in compliance with the regulatory requirement. Based on statistical data collected by the competent authority and industry research institutes, the present paper reports the growth of Taiwan local medical device industry after the enforcement of GMP regulation. Transition in the production, technologies, and number of employees of Taiwan medical device industry between 1998 and 2013 provides the competent authorities around the world with an empirical foundation for further policy development.

  6. Polymer coating embolism from intravascular medical devices - a clinical literature review.

    Science.gov (United States)

    Chopra, Amitabh M; Mehta, Monik; Bismuth, Jean; Shapiro, Maksim; Fishbein, Michael C; Bridges, Alina G; Vinters, Harry V

    Over the past three decades, lubricious (hydrophobic and/or hydrophilic) polymer-coated devices have been increasingly adopted by interventional physicians and vascular surgeons to access and treat a wider range of clinical presentations. Recent clinical literature highlights the presence of polymer coating emboli within the anatomy - a result of coating separation from an intravascular device - and associates it with a range of adverse clinical sequelae. The 2015 U.S. Food and Drug Administration safety communication titled "Lubricious Coating Separation from Intravascular Medical Devices" acknowledges these concerns and concludes that it will work with stakeholders to develop nonclinical test methodologies, establish performance criteria, and identify gaps in current national and international device standards for coating integrity performance. Despite this communication and multiple case reports from interventional physicians, pathologists, dermatologists and other involved physician specialties, polymer coating embolism remains clinically underrecognized. This article consolidates the available literature on polymer coating embolism (1986-2016) and highlights the following relevant information for the physician: (a) the history and elusive nature of polymer coating embolism; (b) potential incidence rates of this phenomenon; (c) reported histologic findings and clinical effects of polymer emboli in the anatomy; (d) the importance of the collaborative clinician-pathologist partnership to report polymer embolism findings; and (e) the importance to study particulate release from intravascular devices so as to further understand and potentially evolve coated interventional technologies. Preliminary research on coatings highlights the potential of using iterations of coatings on medical devices that attain the desired therapeutic result and mitigate or eliminate particulates altogether. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  7. Home Healthcare Medical Devices: Infusion Therapy - Getting the Most Out of Your Pump

    Science.gov (United States)

    ... Medical Procedures Home Health and Consumer Devices Brochure - Home Healthcare Medical Devices: Infusion Therapy - Getting the Most ... if needed. What is the role of your home healthcare provider and supplier in your infusion therapy? ...

  8. Sustained prevention of biofilm formation on a novel silicone matrix suitable for medical devices

    DEFF Research Database (Denmark)

    Steffensen, Søren Langer; Merete H., Vestergaard,; Jensen, Minna Grønning

    2015-01-01

    Bacterial colonization and biofilm formation on medical devices constitute major challenges in clinical long-term use of e.g. catheters due to the risk of (re)infection of patients, which would result in additional use of antibiotics risking bacterial resistance development. The aim of the present...... in the range of 1–20 mg/mL. Devices containing 25% (w/w) hydrogel and loaded with ciprofloxacin displayed a strong antibacterial effect against Staphylococcus aureus bacterial colonization and subsequent biofilm formation on the device material was inhibited for 29 days. In conclusion, the hydrogel...

  9. 76 FR 42713 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of...

    Science.gov (United States)

    2011-07-19

    ...] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of Notice... announcing an amendment to the notice of meeting of the General and Plastic Surgery Devices Panel of the... INFORMATION: In the Federal Register of July 7, 2011, FDA announced that a meeting of the General and Plastic...

  10. El Centro de Cardioestimuladores del Uruguay. CCC Medical Devices

    Directory of Open Access Journals (Sweden)

    Pablo Darscht

    2011-05-01

    Full Text Available Estudio de caso del Centro de Cardioestimuladores del Uruguay - CCC Medical Devices preparado a solicitud de Ingenio en el marco del proyecto financiado por la Iniciativa para Incubadoras de InfoDev - Grupo Banco Mundial. Este estudio detalla los pasos seguidos por una empresa nacional con un fuerte factor de innovación y los cambios producidos en el entorno de los negocios de la empresa. El comienzo de una pequeña empresa de marcapasos que tras pasar por diferentes etapas hoy gana mercados en el área de ingeniería para dispositivos médicos para diferentes empresas de investigación biomédica a nivel internacional.AbstractCase study of the Centro de Cardioestimuladores del Uruguay - CCC Medical Devices prepared on behalf of Ingenio within the project financed by de Incubator Initiative of InfoDev-World Bank Group. This study refers to the steps followed by a highly innovative local company and to the changes in its business environment. The start up of a small pacemakers company that after going through different stages is presently increasing its market share in the area of engineering of medical devices for biomedic research companies worldwide.

  11. LWAs computational platform for e-consultation using mobile devices: cases from developing nations.

    Science.gov (United States)

    Olajubu, Emmanuel Ajayi; Odukoya, Oluwatoyin Helen; Akinboro, Solomon Adegbenro

    2014-01-01

    Mobile devices have been impacting on human standard of living by providing timely and accurate information anywhere and anytime through wireless media in developing nations. Shortage of experts in medical fields is very obvious throughout the whole world but more pronounced in developing nations. Thus, this study proposes a telemedicine platform for the vulnerable areas of developing nations. The vulnerable area are the interior with little or no medical facilities, hence the dwellers are very susceptible to sicknesses and diseases. The framework uses mobile devices that can run LightWeight Agents (LWAs) to send consultation requests to a remote medical expert in urban city from the vulnerable interiors. The feedback is conveyed to the requester through the same medium. The system architecture which contained AgenRoller, LWAs, The front-end (mobile devices) and back-end (the medical server) is presented. The algorithm for the software component of the architecture (AgenRoller) is also presented. The system is modeled as M/M/1/c queuing system, and simulated using Simevents from MATLAB Simulink environment. The simulation result presented show the average queue length, the number of entities in the queue and the number of entities departure from the system. These together present the rate of information processing in the system. A full scale development of this system with proper implementation will help extend the few medical facilities available in the urban cities in developing nations to the interiors thereby reducing the number of casualties in the vulnerable areas of the developing world especially in Sub Saharan Africa.

  12. Current status of the regulation for medical devices

    OpenAIRE

    Shah Anuja; Goyal R

    2008-01-01

    In the light of escalating use of medical devices, stringent regulatory standards are required to ensure that the devices are safe, well studied and have least adverse reactions. Recently introduced guidelines and the amendment in the law will provide adequate guidance for both the manufacturers and competent authorities to manage cases efficiently and appropriately. India has emerged as one of the leaders in pharmaceutical industry. Like many other amendments in Drugs and Cosmetics Act that ...

  13. Interoperability of medical device information and the clinical applications: an HL7 RMIM based on the ISO/IEEE 11073 DIM.

    Science.gov (United States)

    Yuksel, Mustafa; Dogac, Asuman

    2011-07-01

    Medical devices are essential to the practice of modern healthcare services. Their benefits will increase if clinical software applications can seamlessly acquire the medical device data. The need to represent medical device observations in a format that can be consumable by clinical applications has already been recognized by the industry. Yet, the solutions proposed involve bilateral mappings from the ISO/IEEE 11073 Domain Information Model (DIM) to specific message or document standards. Considering that there are many different types of clinical applications such as the electronic health record and the personal health record systems, the clinical workflows, and the clinical decision support systems each conforming to different standard interfaces, detailing a mapping mechanism for every one of them introduces significant work and, thus, limits the potential health benefits of medical devices. In this paper, to facilitate the interoperability of clinical applications and the medical device data, we use the ISO/IEEE 11073 DIM to derive an HL7 v3 Refined Message Information Model (RMIM) of the medical device domain from the HL7 v3 Reference Information Mode (RIM). This makes it possible to trace the medical device data back to a standard common denominator, that is, HL7 v3 RIM from which all the other medical domains under HL7 v3 are derived. Hence, once the medical device data are obtained in the RMIM format, it can easily be transformed into HL7-based standard interfaces through XML transformations because these interfaces all have their building blocks from the same RIM. To demonstrate this, we provide the mappings from the developed RMIM to some of the widely used HL7 v3-based standard interfaces.

  14. Image Quality Characteristics of Handheld Display Devices for Medical Imaging

    Science.gov (United States)

    Yamazaki, Asumi; Liu, Peter; Cheng, Wei-Chung; Badano, Aldo

    2013-01-01

    Handheld devices such as mobile phones and tablet computers have become widespread with thousands of available software applications. Recently, handhelds are being proposed as part of medical imaging solutions, especially in emergency medicine, where immediate consultation is required. However, handheld devices differ significantly from medical workstation displays in terms of display characteristics. Moreover, the characteristics vary significantly among device types. We investigate the image quality characteristics of various handheld devices with respect to luminance response, spatial resolution, spatial noise, and reflectance. We show that the luminance characteristics of the handheld displays are different from those of workstation displays complying with grayscale standard target response suggesting that luminance calibration might be needed. Our results also demonstrate that the spatial characteristics of handhelds can surpass those of medical workstation displays particularly for recent generation devices. While a 5 mega-pixel monochrome workstation display has horizontal and vertical modulation transfer factors of 0.52 and 0.47 at the Nyquist frequency, the handheld displays released after 2011 can have values higher than 0.63 at the respective Nyquist frequencies. The noise power spectra for workstation displays are higher than 1.2×10−5 mm2 at 1 mm−1, while handheld displays have values lower than 3.7×10−6 mm2. Reflectance measurements on some of the handheld displays are consistent with measurements for workstation displays with, in some cases, low specular and diffuse reflectance coefficients. The variability of the characterization results among devices due to the different technological features indicates that image quality varies greatly among handheld display devices. PMID:24236113

  15. "Joint Workshop on High Confidence Medical Devices, Software, and Systems (HCMDSS) and Medical Device Plug-and-Play (MD PnP) Interoperability"

    National Research Council Canada - National Science Library

    Goldman, Julian M

    2008-01-01

    Partial support was requested from TATRC, with joint funding from NSF, for a joint workshop to bring together the synergistic efforts and communities of the High Confidence Medical Devices, Software, and Systems (HCMDSS...

  16. ISO 13485 a complete guide to quality management in the medical device industry

    CERN Document Server

    Abuhav, Itay

    2011-01-01

    Although complex and lengthy, the process of certification for the ISO 13485 can be easily mastered using the simple method outlined in ISO 13485: A Complete Guide to Quality Management in the Medical Device Industry. Written by an experienced industry professional, this practical book provides a complete guide to the ISO 13485 Standard certification for medical device manufacturing. Filled with examples drawn from the author's experience and spanning different sectors and fields of the medical device industry, the book translates the extra ordinary requirements and objectives of the standard

  17. A study on developpement of guideline on writing technical document for electrical medical devices: Dental x-ray equipment

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Youl; Kim, Jae Ryang; Lee, Jun Ho; Park, Chang Won [Division of Medical Device Research, National Institute of Food and Drug Safety Evaluation, Mnistry of Food and Drug Safety (Korea, Republic of)

    2016-12-15

    Due to recent population aging, the number of check-up for senior citizens has increased steadily. According to this trend, the market size of dental X-ray equipment and the number of approval and review for these devices have simultaneously increased. The technical document of medical device is required for approval and review for medical device, and medical device companies needs to have work comprehension and expertise, as the document needs to include the overall contents such as performances, test criteria, etc.. Yet, since most of domestic manufacturers or importers of medical devices are small businesses, it is difficult for them to recruit professional manpower for approval of medical devices, and submission of inaccurate technical documents has increased. These problems lead to delay of the approval process and to difficulties in quick entering into the market. Especially, the Ministry of Food and Drug safety (MFDS) standards of a dental extra-oral X-ray equipment, a dental intra-oral X-ray equipment, an arm-type computed tomography, and a portable X-ray system have been recently enacted or not. this guideline of dental X-ray equipment adjusting revised standards was developed to help relative companies and reviewers. For this study, first, the methods to write technical document have been reviewed with revised international and domestic regulations and system. Second, the domestic and foreign market status of each item has been surveyed and analyzed. Third, the contents of technical documents already approved by MFDS have been analyzed to select the correct example, test items, criteria, and methods. Finally, the guideline has been developed based on international and domestic regulation, through close review of a consultative body composed of academic, industrial, research institute and government experts.

  18. A study on developpement of guideline on writing technical document for electrical medical devices: Dental x-ray equipment

    International Nuclear Information System (INIS)

    Lee, Seung Youl; Kim, Jae Ryang; Lee, Jun Ho; Park, Chang Won

    2016-01-01

    Due to recent population aging, the number of check-up for senior citizens has increased steadily. According to this trend, the market size of dental X-ray equipment and the number of approval and review for these devices have simultaneously increased. The technical document of medical device is required for approval and review for medical device, and medical device companies needs to have work comprehension and expertise, as the document needs to include the overall contents such as performances, test criteria, etc.. Yet, since most of domestic manufacturers or importers of medical devices are small businesses, it is difficult for them to recruit professional manpower for approval of medical devices, and submission of inaccurate technical documents has increased. These problems lead to delay of the approval process and to difficulties in quick entering into the market. Especially, the Ministry of Food and Drug safety (MFDS) standards of a dental extra-oral X-ray equipment, a dental intra-oral X-ray equipment, an arm-type computed tomography, and a portable X-ray system have been recently enacted or not. this guideline of dental X-ray equipment adjusting revised standards was developed to help relative companies and reviewers. For this study, first, the methods to write technical document have been reviewed with revised international and domestic regulations and system. Second, the domestic and foreign market status of each item has been surveyed and analyzed. Third, the contents of technical documents already approved by MFDS have been analyzed to select the correct example, test items, criteria, and methods. Finally, the guideline has been developed based on international and domestic regulation, through close review of a consultative body composed of academic, industrial, research institute and government experts

  19. RESULTS OF THE SURVEY CONDUCTED AMONG OPHTHALMOLOGISTS ON THE ISSUE OF EQUIPMENT OF MEDICAL INSTITUTIONS WITH OPHTHALMOLOGY DEVICES

    Directory of Open Access Journals (Sweden)

    S. V. Seraphimov

    2017-01-01

    Full Text Available Introduction. The problem of limited accessibility and quality of ophthalmic medical care remains one of the leading ones in the national healthcare. This article presents results of the survey conducted among ophthalmologists about the effect of large-scale equipment of all medical institutions in the Leningrad Region with modern ophthalmologic devices over the recent years.Objective is to determine the contribution of the health care modernization program to equipping the medical institutions of the Leningrad Region with modern ophthalmologic medical devices, and to identify the main areas for improving the ophthalmologic care for residents of the Leningrad region with cataracts.Materials and methods. According to a specially developed questionnaire, 105 ophthalmologists from the Leningrad Region were interviewed. The survey was conducted among physicians working both in out-patient medical facilities and in medical facilities with in-patient modalities.Results. The results of the study confirmed positive changes that occurred in recent years as a result of equipping medical institutions with modern medical devices. Almost two-thirds (59.9% of respondents noted that equipping with modern medical devices had a significant impact on the quality of the medical and diagnostic measures carried out in healthcare facilities of the region.Conclusions. The equipment had a significant impact on the diagnosis and treatment of all kinds of diseases of the eye and its appendages, especially such eye disease which is so common among the population of the Leningrad Region as cataracts (75.0 per 100 ophthalmologists surveyed. At the same time, in spite of these efforts, the standard for equipping ophthalmologic departments in individual medical institutions has not been fully provided. Only every fifth (20.9% ophthalmologist noted during the survey that the list of available ophthalmic devices was sufficient, and that they all worked properly.

  20. 78 FR 66941 - Design Considerations for Pivotal Clinical Investigations for Medical Devices; Guidance for...

    Science.gov (United States)

    2013-11-07

    .... 66, rm. 2110, Silver Spring, MD 20993-0002, 301- 796-5750. For devices regulated by CBER: Stephen... the best clinical and statistical practices for investigational medical device studies. A medical...

  1. Reducing hospital noise: a review of medical device alarm management.

    Science.gov (United States)

    Konkani, Avinash; Oakley, Barbara; Bauld, Thomas J

    2012-01-01

    Increasing noise in hospital environments, especially in intensive care units (ICUs) and operating rooms (ORs), has created a formidable challenge for both patients and hospital staff. A major contributing factor for the increasing noise levels in these environments is the number of false alarms generated by medical devices. This study focuses on discovering best practices for reducing the number of false clinical alarms in order to increase patient safety and provide a quiet environment for both work and healing. The researchers reviewed Pub Med, Web of Knowledge and Google Scholar sources to obtain original journal research and review articles published through January 2012. This review includes 27 critically important journal articles that address different aspects of medical device alarms management, including the audibility, identification, urgency mapping, and response time of nursing staff and different solutions to such problems. With current technology, the easiest and most direct method for reducing false alarms is to individualize alarm settings for each patient's condition. Promoting an institutional culture change that emphasizes the importance of individualization of alarms is therefore an important goal. Future research should also focus on the development of smart alarms.

  2. 'It's on my iPhone': attitudes to the use of mobile computing devices in medical education, a mixed-methods study.

    Science.gov (United States)

    Wallace, Sean; Clark, Marcia; White, Jonathan

    2012-01-01

    The last decade has seen the introduction of new technology which has transformed many aspects of our culture, commerce, communication and education. This study examined how medical teachers and learners are using mobile computing devices such as the iPhone in medical education and practice, and how they envision them being used in the future. Semistructured interviews were conducted with medical students, residents and faculty to examine participants' attitudes about the current and future use of mobile computing devices in medical education and practice. A thematic approach was used to summarise ideas and concepts expressed, and to develop an online survey. A mixed methods approach was used to integrate qualitative and quantitative findings. Medical students, residents and faculty at a large Canadian medical school in 2011. Interviews were conducted with 18 participants (10 students, 7 residents and 1 faculty member). Only 213 participants responded to the online survey (76 students, 65 residents and 41 faculty members). Over 85% of participants reported using a mobile-computing device. The main uses described for mobile devices related to information management, communication and time management. Advantages identified were portability, flexibility, access to multimedia and the ability to look up information quickly. Challenges identified included: superficial learning, not understanding how to find good learning resources, distraction, inappropriate use and concerns about access and privacy. Both medical students and physicians expressed the view that the use of these devices in medical education and practice will increase in the future. This new technology offers the potential to enhance learning and patient care, but also has potential problems associated with its use. It is important for leadership in medical schools and healthcare organisations to set the agenda in this rapidly developing area to maximise the benefits of this powerful new technology while

  3. OR.NET RT: how service-oriented medical device architecture meets real-time communication.

    Science.gov (United States)

    Pfeiffer, Jonas H; Kasparick, Martin; Strathen, Benjamin; Dietz, Christian; Dingler, Max E; Lueth, Tim C; Timmermann, Dirk; Radermacher, Klaus; Golatowski, Frank

    2018-02-23

    Today's landscape of medical devices is dominated by stand-alone systems and proprietary interfaces lacking cross-vendor interoperability. This complicates or even impedes the innovation of novel, intelligent assistance systems relying on the collaboration of medical devices. Emerging approaches use the service-oriented architecture (SOA) paradigm based on Internet protocol (IP) to enable communication between medical devices. While this works well for scenarios with no or only soft timing constraints, the underlying best-effort communication scheme is insufficient for time critical data. Real-time (RT) networks are able to reliably guarantee fixed latency boundaries, for example, by using time division multiple access (TDMA) communication patterns. However, deterministic RT networks come with their own limitations such as tedious, inflexible configuration and a more restricted bandwidth allocation. In this contribution we overcome the drawbacks of both approaches by describing and implementing mechanisms that allow the two networks to interact. We introduce the first implementation of a medical device network that offers hard RT guarantees for control and sensor data and integrates into SOA networks. Based on two application examples we show how the flexibility of SOA networks and the reliability of RT networks can be combined to achieve an open network infrastructure for medical devices in the operating room (OR).

  4. Humanitarian Use Devices/Humanitarian Device Exemptions in cardiovascular medicine.

    Science.gov (United States)

    Kaplan, Aaron V; Harvey, Elisa D; Kuntz, Richard E; Shiran, Hadas; Robb, John F; Fitzgerald, Peter

    2005-11-01

    The Second Dartmouth Device Development Symposium held in October 2004 brought together leaders from the medical device community, including clinical investigators, senior representatives from the US Food and Drug Administration, large and small device manufacturers, and representatives from the financial community to examine difficult issues confronting device development. The role of the Humanitarian Use Device/Humanitarian Device Exemption (HUD/HDE) pathway in the development of new cardiovascular devices was discussed in this forum. The HUD/HDE pathway was created by Congress to facilitate the availability of medical devices for "orphan" indications, ie, those affecting HDEs have been granted (23 devices, 6 diagnostic tests). As the costs to gain regulatory approval for commonly used devices increase, companies often seek alternative ways to gain market access, including the HUD/HDE pathway. For a given device, there may be multiple legitimate and distinct indications, including indications that meet the HUD criteria. Companies must choose how and when to pursue each of these indications. The consensus of symposium participants was for the HUD/HDE pathway to be reserved for true orphan indications and not be viewed strategically as part of the clinical development plan to access a large market.

  5. Developing a reproducible non-line-of-sight experimental setup for testing wireless medical device coexistence utilizing ZigBee.

    Science.gov (United States)

    LaSorte, Nickolas J; Rajab, Samer A; Refai, Hazem H

    2012-11-01

    The integration of heterogeneous wireless technologies is believed to aid revolutionary healthcare delivery in hospitals and residential care. Wireless medical device coexistence is a growing concern given the ubiquity of wireless technology. In spite of this, a consensus standard that addresses risks associated with wireless heterogeneous networks has not been adopted. This paper serves as a starting point by recommending a practice for assessing the coexistence of a wireless medical device in a non-line-of-sight environment utilizing 802.15.4 in a practical, versatile, and reproducible test setup. This paper provides an extensive survey of other coexistence studies concerning 802.15.4 and 802.11 and reports on the authors' coexistence testing inside and outside an anechoic chamber. Results are compared against a non-line-of-sight test setup. Findings relative to co-channel and adjacent channel interference were consistent with results reported in the literature.

  6. Mobile devices in medicine: a survey of how medical students, residents, and faculty use smartphones and other mobile devices to find information*

    Science.gov (United States)

    Boruff, Jill T.; Storie, Dale

    2014-01-01

    Objectives: The research investigated the extent to which students, residents, and faculty members in Canadian medical faculties use mobile devices, such as smartphones (e.g., iPhone, Android, Blackberry) and tablet computers (e.g., iPad), to answer clinical questions and find medical information. The results of this study will inform how health libraries can effectively support mobile technology and collections. Methods: An electronic survey was distributed by medical librarians at four Canadian universities to medical students, residents, and faculty members via departmental email discussion lists, personal contacts, and relevant websites. It investigated the types of information sought, facilitators to mobile device use in medical information seeking, barriers to access, support needs, familiarity with institutionally licensed resources, and most frequently used resources. Results: The survey of 1,210 respondents indicated widespread use of smartphones and tablets in clinical settings in 4 Canadian universities. Third- and fourth-year undergraduate students (i.e., those in their clinical clerkships) and medical residents, compared to other graduate students and faculty, used their mobile devices more often, used them for a broader range of activities, and purchased more resources for their devices. Conclusions: Technological and intellectual barriers do not seem to prevent medical trainees and faculty from regularly using mobile devices for their medical information searches; however, barriers to access and lack of awareness might keep them from using reliable, library-licensed resources. Implications: Libraries should focus on providing access to a smaller number of highly used mobile resources instead of a huge collection until library-licensed mobile resources have streamlined authentication processes. PMID:24415916

  7. Mobile devices in medicine: a survey of how medical students, residents, and faculty use smartphones and other mobile devices to find information.

    Science.gov (United States)

    Boruff, Jill T; Storie, Dale

    2014-01-01

    The research investigated the extent to which students, residents, and faculty members in Canadian medical faculties use mobile devices, such as smartphones (e.g., iPhone, Android, Blackberry) and tablet computers (e.g., iPad), to answer clinical questions and find medical information. The results of this study will inform how health libraries can effectively support mobile technology and collections. An electronic survey was distributed by medical librarians at four Canadian universities to medical students, residents, and faculty members via departmental email discussion lists, personal contacts, and relevant websites. It investigated the types of information sought, facilitators to mobile device use in medical information seeking, barriers to access, support needs, familiarity with institutionally licensed resources, and most frequently used resources. The survey of 1,210 respondents indicated widespread use of smartphones and tablets in clinical settings in 4 Canadian universities. Third- and fourth-year undergraduate students (i.e., those in their clinical clerkships) and medical residents, compared to other graduate students and faculty, used their mobile devices more often, used them for a broader range of activities, and purchased more resources for their devices. Technological and intellectual barriers do not seem to prevent medical trainees and faculty from regularly using mobile devices for their medical information searches; however, barriers to access and lack of awareness might keep them from using reliable, library-licensed resources. Libraries should focus on providing access to a smaller number of highly used mobile resources instead of a huge collection until library-licensed mobile resources have streamlined authentication processes.

  8. Implantable Medical Devices; Networking Security Survey

    OpenAIRE

    Siamak Aram; Rouzbeh A. Shirvani; Eros G. Pasero; Mohamd F. Chouikha

    2016-01-01

    The industry of implantable medical devices (IMDs) is constantly evolving, which is dictated by the pressing need to comprehensively address new challenges in the healthcare field. Accordingly, IMDs are becoming more and more sophisticated. Not long ago, the range of IMDs’ technical capacities was expanded, making it possible to establish Internet connection in case of necessity and/or emergency situation for the patient. At the same time, while the web connectivity of today’s implantable dev...

  9. Framework conditions and requirements to ensure the technical functional safety of reprocessed medical devices.

    Science.gov (United States)

    Kraft, Marc

    2008-09-03

    Testing and restoring technical-functional safety is an essential part of medical device reprocessing. Technical functional tests have to be carried out on the medical device in the course of the validation of reprocessing procedures. These ensure (in addition to the hygiene tests) that the reprocessing procedure is suitable for the medical device. Functional tests are, however, also a part of reprocessing procedures. As a stage in the reprocessing, they ensure for the individual medical device that no damage or other changes limit the performance. When determining which technical-functional tests are to be carried out, the current technological standard has to be taken into account in the form of product-specific and process-oriented norms. Product-specific norms primarily define safety-relevant requirements. The risk management method described in DIN EN ISO 14971 is the basis for recognising hazards; the likelihood of such hazards arising can be minimised through additional technical-functional tests, which may not yet have been standardised. Risk management is part of a quality management system, which must be bindingly certified for manufacturers and processors of critical medical devices with particularly high processing demands by a body accredited by the competent authority.

  10. 77 FR 3781 - Pediatric Medical Devices; Public Workshop; Reopening of Comment Period

    Science.gov (United States)

    2012-01-25

    ... devices. DATES: Submit either electronic or written comments by March 5, 2012. ADDRESSES: Submit.... Designing pediatric medical devices can be challenging; children are often smaller and more active than adults; body structures and functions change throughout childhood, and children may be long-term device...

  11. 78 FR 27971 - Dental Products Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2013-05-13

    ...] Dental Products Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and Drug...: Dental Products Panel of the Medical Devices Advisory Committee. General Function of the Committee: To... regulatory classification for dental devices known as Endosseous Dental Implants (Blade-form), one of the...

  12. A medical application integrating remote 3D visualization tools to access picture archiving and communication system on mobile devices.

    Science.gov (United States)

    He, Longjun; Ming, Xing; Liu, Qian

    2014-04-01

    With computing capability and display size growing, the mobile device has been used as a tool to help clinicians view patient information and medical images anywhere and anytime. However, for direct interactive 3D visualization, which plays an important role in radiological diagnosis, the mobile device cannot provide a satisfactory quality of experience for radiologists. This paper developed a medical system that can get medical images from the picture archiving and communication system on the mobile device over the wireless network. In the proposed application, the mobile device got patient information and medical images through a proxy server connecting to the PACS server. Meanwhile, the proxy server integrated a range of 3D visualization techniques, including maximum intensity projection, multi-planar reconstruction and direct volume rendering, to providing shape, brightness, depth and location information generated from the original sectional images for radiologists. Furthermore, an algorithm that changes remote render parameters automatically to adapt to the network status was employed to improve the quality of experience. Finally, performance issues regarding the remote 3D visualization of the medical images over the wireless network of the proposed application were also discussed. The results demonstrated that this proposed medical application could provide a smooth interactive experience in the WLAN and 3G networks.

  13. Moving Up the Value Chain : A Study of Malaysia's Solar and Medical Device Industries

    OpenAIRE

    World Bank

    2011-01-01

    This report responds to a request by the Government of Malaysia to examine how Malaysia can move up the value chain in the solar and medical device industries. Through the lens of long-term development, the overall growth performance of the Malaysian economy has been a resounding success story. The Commission on growth and development listed Malaysia as one of only 13 countries that regist...

  14. An extended protocol for usability validation of medical devices : Research design and reference model

    NARCIS (Netherlands)

    Schmettow, M.; Schnittker, R.; Schraagen, J.M.

    2017-01-01

    This paper proposes and demonstrates an extended protocol for usability validation testing of medical devices. A review of currently used methods for the usability evaluation of medical devices revealed two main shortcomings. Firstly, the lack of methods to closely trace the interaction sequences

  15. Distribution of microorganisms in medical devices and their inactivation effects by gamma-irradiation

    International Nuclear Information System (INIS)

    Ito, Hitoshi; Ishigaki, Isao

    1986-01-01

    Radiation treatment is getting important position for sterilizing medical devices and for packaging films of foods. Recently, survey of bioburden is an important technique for evaluation of sterility doses for medical devices. However, many studies have been done mainly on the irradiation effects of spore-forming bacteria in medical devices. In this study, radiation sensitivity of spore-forming bacteria and fungi were examined after the survey on distribution of microorganisms in several kinds of medical devices. The main contaminant in disposable syringes, needles and conical flasks were consisted of Bacillus, with lesser amount of Micrococcus, Pseudomonas, Peptococcaceae and fungi as positive of 5 - 60 % in the medical devices which cultivated in thioglycolate broth. Bacillus group were identified as B. pumilus, B. sphaericus, B. coagulans, B. megaterium and etc. Fungi were isolated a lesser amounts compared with spore-forming bacteria and identified as Blastomyces, Penicillium, Haplosporangium, Euricoa and Audeobasidium. Peptococaceae were not isolated after irradiation with a dose of 0.1 Mrad even the samples were contaminated with high percentage. The D 10 values of dryed endospores of Bacillus-isolates which attached to the filter paper with pepton-glycerin were obtained to be 0.11 - 0.19 Mrad. The D 10 values of many isolates of fungi in dry condition were obtained below 0.08 Mrad. However, the isolate of Aureobasidium is radiation-resistant, and it's D 10 values was obtained as 0.28 Mrad under aerobic and anaerobic dry condition. (author)

  16. Medical devices of the head, neck, and spine.

    Science.gov (United States)

    Hunter, Tim B; Yoshino, Mark T; Dzioba, Robert B; Light, Rick A; Berger, William G

    2004-01-01

    There are many medical devices used for head, neck, and spinal diseases and injuries, and new devices are constantly being introduced. Many of the newest devices are variations on a previous theme. Knowing the specific name of a device is not important. It is important to recognize the presence of a device and to have an understanding of its function as well as to be able to recognize the complications associated with its use. The article discusses the most common and important devices of the head, neck, and spine, including cerebrospinal fluid shunts and the Codman Hakim programmable valve; subdural drainage catheters, subdural electrodes, intracranial electrodes, deep brain stimulators, and cerebellar electrodes; coils, balloons, adhesives, particles, and aneurysm clips; radiation therapy catheters, intracranial balloons for drug installation, and carmustine wafers; hearing aids, cochlear implants, and ossicular reconstruction prostheses; orbital prostheses, intraocular silicone oil, and lacrimal duct stents; anterior and posterior cervical plates, posterior cervical spine wiring, odontoid fracture fixation devices, cervical collars and halo vests; thoracic and lumbar spine implants, anterior and posterior instrumentation for the thoracic and lumbar spine, vertebroplasty, and artificial disks; spinal column stimulators, bone stimulators, intrathecal drug delivery pumps, and sacral stimulators; dental and facial implant devices; gastric and tracheal tubes; vagus nerve stimulators; lumboperitoneal shunts; and temperature- and oxygen-sensing probes. Copyright RSNA, 2004

  17. Factors that influence the recognition, reporting and resolution of incidents related to medical devices and other healthcare technologies: a systematic review.

    Science.gov (United States)

    Polisena, Julie; Gagliardi, Anna; Urbach, David; Clifford, Tammy; Fiander, Michelle

    2015-03-29

    analysis in future studies. Since evidence gaps on medical device-related incidents exist, telephone interviews with frontline clinicians will be conducted to solicit information about their experiences with medical devices and suggested strategies for device surveillance improvement in a hospital context. Further research also should investigate the impact of human, system, organizational and education factors on the development and implementation of local medical device surveillance systems.

  18. Mobile Medical Apps and mHealth Devices: A Framework to Build Medical Apps and mHealth Devices in an Ethical Manner to Promote Safer Use - A Literature Review.

    Science.gov (United States)

    Sharp, Mary; O'Sullivan, Declan

    2017-01-01

    This paper presents a preliminary literature review in the area of ethics in the development of Mobile Medical Apps and mHealth. The review included both direct health apps and also apps marketed under the area of well-being in addition to mHealth devices. The following words and combinations of them were used to carry out the search for publications, mHealth, Apps, Ethics. The search engines used were Google Scholar, and PubMed. The paper is restricted to publications since 2012. The total number of papers found was 1,920 of which 84 were reviewed. The reason for so few being reviewed was that the majority only considered security. The search revealed many papers dealing with security for all types of apps and mHealth devices but there are very few papers dealing with the ethical issues related to Apps or mHealth devices in the area. It is noted however that the number of apps is increasing in number exponentially and therefore it is argued that it is necessary to pay attention to the ethical aspects. There are now estimated to be 165,000 apps available in this area. How ethics are addressed in health and well-being apps is important as they can have an effect on the health of the individual using them. In a similar way, the need for addressing ethical issues for development of well-being apps is evident. In a study [1] it was noted that even though Electronic Health Record (EHR) was the highest ranked tablet-related task only one third of clinicians said that EHR was optimized for smartphones. When apps are integrated with the EHR they fully optimize productivity. In the same study the significant challenges identified included the method of evaluation and selection of mobile health solutions in order to ensure that clinical outcomes, care and efficiency are included. Security is mentioned but again wider ethical issues were not a consideration. From the literature review it is clear that there is a need for guidelines for how developers of medical ad well

  19. 75 FR 18219 - Drug and Medical Device Forum on Food and Drug Administration Drug and Device Requirements and...

    Science.gov (United States)

    2010-04-09

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0142] Drug and Medical Device Forum on Food and Drug Administration Drug and Device Requirements and Supplier Controls; Public Educational Forum AGENCY: Food and Drug Administration, HHS. ACTION: Notice of public...

  20. Special funding schemes for innovative medical devices in French hospitals: the pros and cons of two different approaches.

    Science.gov (United States)

    Martelli, Nicolas; van den Brink, Hélène

    2014-07-01

    Financing innovative medical devices is an important challenge for national health policy makers, and a crucial issue for hospitals. However, when innovative medical devices are launched on the European market there is generally little clinical evidence regarding both efficacy and safety, both because of the flaws in the European system for regulating such devices, and because they are at an early stage of development. To manage the uncertainty surrounding the reimbursement of innovation, several European countries have set up temporary funding schemes to generate evidence about the effectiveness of devices. This article explores two different French approaches to funding innovative in-hospital devices and collecting supplementary data: the coverage with evidence development (CED) scheme introduced under Article L. 165-1-1 of the French Social Security Code; and national programs for hospital-based research. We discuss pros and cons of both approaches in the light of CED policies in Germany and the UK. The CED policies for devices share common limitations. Thus, transparency of CED processes should be enhanced and decisions need to be made in a timely way. Finally, we think that closer collaboration between manufacturers, health authorities and hospitals is essential to make CED policies more operational. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  1. Advertising of medical devices: foreign experience and Ukrainian practice.

    Science.gov (United States)

    Pashkov, Vitalii; Harkusha, Andrii; Bytiak, Oleksii

    Chosen European foreign policy vector for Ukraine establishes its obligation to enforce the process of adaptation of the EU law regulations in the internal legal policy. The approximation of Ukrainian law to the European Union (EU) "acquis communautaire" is not only the instrument for deepening our economic cooperation with the European Union, but also the important measure to enhance further development of Ukraine in general. National legislation, which regulate advertising and promotion of medical devices (MD), is not an exception. Some key points on legal regulation of abovementioned sphere is a base of this study. Ukrainian legislation, European Union`s Law Acts, EU's member-states law, WHO Acts and Recommendations, European Medical Technology Industry Association (EUCOMED) Acts. Article is based on dialectical, comparative, analytic, synthetic and comprehensive research methods. In accordance with Ukrainian legislation, there is no special law that concerns advertising on MD in Ukraine, this sphere is regulated by general law that named ≪About advertisement≫, but it doesn't take into account even main characteristics of such a special object as medical devices (MD). Moreover, the law ≪About advertisement≫ contain discrepancies in terms that are used, these contradictions, in our opinion, must be eliminated by appropriate law reforms. The advertising and promotion of MD in EU is regulated by a combination of EU and national legislation of EU Member States, national advertising and promotion of MD are not harmonized with the EU MDD for now, resulting in a fragmented legal landscape that differs from one EU Member State to the other. Practice of adopting different codes and guides that regulate advertising, including advertising of MD, is widespread in EU and EU Member States and thus must be used in Ukraine with appropriate reformation of national law.

  2. Recent developments in drug eluting devices with tailored interfacial properties.

    Science.gov (United States)

    Sanchez-Rexach, Eva; Meaurio, Emilio; Sarasua, Jose-Ramon

    2017-11-01

    Drug eluting devices have greatly evolved during past years to become fundamental products of great marketing importance in the biomedical field. There is currently a large diversity of highly specialized devices for specific applications, making the development of these devices an exciting field of research. The replacement of the former bare metal devices by devices loaded with drugs allowed the sustained and controlled release of drugs, to achieve the desired local therapeutic concentration of drug. The newer devices have been "engineered" with surfaces containing micro- and nanoscale features in a well-controlled manner, that have shown to significantly affect cellular and subcellular function of various biological systems. For example, the topography can be structured to form an antifouling surface mimicking the defense mechanisms found in nature, like the skin of the shark. In the case of bone implants, well-controlled nanostructured interfaces can promote osteoblast differentiation and matrix production, and enhance short-term and long-term osteointegration. In any case, the goal of current research is to design implants that induce controlled, guided, and rapid healing. This article reviews recent trends in the development of drug eluting devices, as well as recent developments on the micro/nanotechnology scales, and their future challenges. For this purpose medical devices have been divided according to the different systems of the body they are focused to: orthopedic devices, breathing stents, gastrointestinal and urinary systems, devices for cardiovascular diseases, neuronal implants, and wound dressings. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Linking Engineering and Medical Training: A USC program seeks to introduce medical and engineering students to medical device development.

    Science.gov (United States)

    Tolomiczenko, George; Sanger, Terry

    2015-01-01

    Medical students are attracted by the prospect of a meaningful addition to their clinical work. Engineering students are excited by a unique opportunity to learn directly alongside their medical student peers. For both, as well as the scientific community at large, the boutique program at the University of Southern California (USC) linking engineering and medical training at the graduate level is instructive of a new way of approaching engineering education that can potentially provide benefits to both students and society. Students who have grown up in an era of ?mass customization? in the retail and service industries can enjoy that same degree of flexibility also in the realm of education. At the same time, society gains engineers who have developed an increased empathy and awareness of the clinical contexts in which their innovations will be implemented.

  4. #DDOD Use Case: Consolidated reporting of medical device recalls

    Data.gov (United States)

    U.S. Department of Health & Human Services — SUMMARY DDOD use case request for consolidated, consistent reporting of medical device recalls. WHAT IS A USE CASE? A “Use Case” is a request that was made by the...

  5. [Hospital-based health technology assessment in France: how to proceed to evaluate innovative medical devices?].

    Science.gov (United States)

    Martelli, N; van den Brink, H; Denies, F; Dervaux, B; Germe, A F; Prognon, P; Pineau, J

    2014-01-01

    Innovative medical devices offer solutions to medical problems and greatly improve patients' outcomes. Like National Health Technology Assessment (HTA) agencies, hospitals face numerous requests for innovative and costly medical devices. To help local decision-makers, different approaches of hospital-based HTA (HB-HTA) have been adopted worldwide. The objective of the present paper is to explore HB-HTA models for adopting innovative medical devices in France and elsewhere. Four different models have been conceptualized: "ambassador" model, "mini-HTA" model, "HTA unit" model and "internal committee". Apparently, "HTA unit" and "internal committee" (or a mixture of both models) are the prevailing HB-HTA models in France. Nevertheless, some weaknesses of these models have been pointed out in previous works. Only few examples involving hospital pharmacists have been found abroad, except in France and in Italy. Finally, the harmonization of the assessment of innovative medical devices in France needs a better understanding of HB-HTA practices. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  6. Optimised design and development of a bio-medical healthcare device through quality function deployment (QFD).

    Science.gov (United States)

    Sharma, Jitendra

    2012-01-01

    Technology is major stimulus for change and is imbibed in various forms; especially in the field of medical devices and bio-medical instruments used in life and death situations. Cardiotocograph (CTG), a foetal heart rate and uterine contraction monitoring and measurement machine, is a valuable tool in the process of childbirth. The Quality Function Deployment (QFD) is an engineering technique with the number one priority being to satisfy the customer. The aim of using QFD in this paper is to highlight the limitations and complexities of the present instrument. The paper attempts to first discuss out the operational details of the instrument along with a brief review of the relevant literature. Following this, its functional analysis is carried out through QFD - a TQM tool. The resultant outcome enlists CTG functions with their Raw Weight and Priority Score. A detailed theoretical analysis of results pinpoints basic functional limitation of exiting machine.

  7. Security and privacy for implantable medical devices

    CERN Document Server

    Carrara, Sandro

    2014-01-01

     This book presents a systematic approach to analyzing the challenging engineering problems posed by the need for security and privacy in implantable medical devices (IMD).  It describes in detail new issues termed as lightweight security, due to the associated constraints on metrics such as available power, energy, computing ability, area, execution time, and memory requirements. Coverage includes vulnerabilities and defense across multiple levels, with basic abstractions of cryptographic services and primitives such as public key cryptography, block ciphers and digital signatures. Experts from engineering introduce to some IMD systems that have  recently been proposed and developed. Experts from Computer Security and Cryptography present new research, which shows vulnerabilities in existing IMDs and proposes solutions. Experts from Privacy Technology and Policy will discuss the societal, legal and ethical challenges surrounding IMD security as well as technological solutions that build on the latest in C...

  8. Promising silicones modified with cationic biocides for the development of antimicrobial medical devices.

    Science.gov (United States)

    Ghamrawi, Sarah; Bouchara, Jean-Philippe; Tarasyuk, Oksana; Rogalsky, Sergiy; Lyoshina, Lyudmila; Bulko, Olga; Bardeau, Jean-François

    2017-06-01

    We have tested silicones containing 2% or 5% of the cationic biocides polyhexamethylene guanidine dodecylbenzenesulfonate (PHMG-DBS), 1-octyl-3-methylimidazolium tetrafluoroborate (OMIM-BF 4 ) or 1-dodecyl-3-methylimidazolium tetrafluoroborate (DMIM-BF 4 ) against the major relevant bacterial and yeast species in health care-associated infections (HCAI). Study conducted according to the international standard ISO 22196 revealed that silicones containing 2% or 5% DMIM-BF 4 or 5% PHMG-DBS presented the highest antimicrobial activity, leading to a logarithmic growth reduction of 3.03 to 6.46 and 3.65 to 4.85 depending on the bacterial or fungal species. Heat-pretreated silicones containing 2% DMIM-BF 4 kept a high activity, with at least a 3-log reduction in bacterial growth, except against P. aeruginosa where there was only a 1.1-log reduction. After 33days, the release ratio of cationic biocide from silicone films containing 5% of DMIM-BF 4 was found to be 5.6% in pure water and 1.9% in physiological saline solution, respectively. No leaching of PHMG-DBS polymeric biocide was detected under the same conditions. These results demonstrate unambiguously that silicones containing 2% DMIM-BF 4 or 5% PHMG-DBS present high antimicrobial activity, as well as high leaching resistance and therefore may be good candidates for the development of safer medical devices. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Wireless communication with implanted medical devices using the conductive properties of the body.

    Science.gov (United States)

    Ferguson, John E; Redish, A David

    2011-07-01

    Many medical devices that are implanted in the body use wires or wireless radiofrequency telemetry to communicate with circuitry outside the body. However, the wires are a common source of surgical complications, including breakage, infection and electrical noise. In addition, radiofrequency telemetry requires large amounts of power and results in low-efficiency transmission through biological tissue. As an alternative, the conductive properties of the body can be used to enable wireless communication with implanted devices. In this article, several methods of intrabody communication are described and compared. In addition to reducing the complications that occur with current implantable medical devices, intrabody communication can enable novel types of miniature devices for research and clinical applications.

  10. The PMA Scale: A Measure of Physicians' Motivation to Adopt Medical Devices.

    Science.gov (United States)

    Hatz, Maximilian H M; Sonnenschein, Tim; Blankart, Carl Rudolf

    2017-04-01

    Studies have often stated that individual-level determinants are important drivers for the adoption of medical devices. Empirical evidence supporting this claim is, however, scarce. At the individual level, physicians' adoption motivation was often considered important in the context of adoption decisions, but a clear notion of its dimensions and corresponding measurement scales is not available. To develop and subsequently validate a scale to measure the motivation to adopt medical devices of hospital-based physicians. The development and validation of the physician-motivation-adoption (PMA) scale were based on a literature search, internal expert meetings, a pilot study with physicians, and a three-stage online survey. The data collected in the online survey were analyzed using exploratory factor analysis (EFA), and the PMA scale was revised according to the results. Confirmatory factor analysis (CFA) was conducted to test the results from the EFA in the third stage. Reliability and validity tests and subgroup analyses were also conducted. Overall, 457 questionnaires were completed by medical personnel of the National Health Service England. The EFA favored a six-factor solution to appropriately describe physicians' motivation. The CFA confirmed the results from the EFA. Our tests indicated good reliability and validity of the PMA scale. This is the first reliable and valid scale to measure physicians' adoption motivation. Future adoption studies assessing the individual level should include the PMA scale to obtain more information about the role of physicians' motivation in the broader adoption context. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  11. Post-market clinical research conducted by medical device manufacturers: a cross-sectional survey.

    Science.gov (United States)

    Ross, Joseph S; Blount, Katrina L; Ritchie, Jessica D; Hodshon, Beth; Krumholz, Harlan M

    2015-01-01

    In the US, once a medical device is made available for use, several requirements have been established by the US Food and Drug Administration (FDA) to ensure ongoing post-market surveillance of device safety and effectiveness. Our objective was to determine how commonly medical device manufacturers initiate post-market clinical studies or augment FDA post-market surveillance requirements for higher-risk devices that are most often approved via the FDA's pre-market approval (PMA) pathway. We conducted a cross-sectional survey of 47 manufacturers with operations in California, Minnesota, and Massachusetts who market devices approved via the PMA pathway. Among 22 respondents (response rate =47%), nearly all self-reported conducting post-market clinical research studies, commonly between 1 and 5; only 1 respondent reported never conducting post-market clinical research studies. While manufacturers most often engaged in these studies to satisfy FDA requirements, other reasons were reported, including performance monitoring and surveillance and market acceptance initiatives. Risks of conducting and not conducting post-market clinical research studies were described through open-ended response to questions. Medical device manufacturers commonly initiate post-market clinical studies at the request of the FDA. Clinical data from these studies should be integrated into national post-market surveillance initiatives.

  12. 78 FR 35940 - Content of Premarket Submissions for Management of Cybersecurity in Medical Devices; Draft...

    Science.gov (United States)

    2013-06-14

    ...] Content of Premarket Submissions for Management of Cybersecurity in Medical Devices; Draft Guidance for... draft guidance entitled ``Content of Premarket Submissions for Management of Cybersecurity in Medical Devices.'' This guidance identifies cybersecurity issues that manufacturers should consider in preparing...

  13. Grazing incidence angle based sensing approach integrated with fiber-optic Fourier transform infrared (FO-FTIR) spectroscopy for remote and label-free detection of medical device contaminations

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, Moinuddin, E-mail: moinuddin.hassan@fda.hhs.gov; Ilev, Ilko [Optical Therapeutics and Medical Nanophotonics Laboratory, Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland 20993 (United States)

    2014-10-15

    Contamination of medical devices has become a critical and prevalent public health safety concern since medical devices are being increasingly used in clinical practices for diagnostics, therapeutics and medical implants. The development of effective sensing methods for real-time detection of pathogenic contamination is needed to prevent and reduce the spread of infections to patients and the healthcare community. In this study, a hollow-core fiber-optic Fourier transform infrared spectroscopy methodology employing a grazing incidence angle based sensing approach (FO-FTIR-GIA) was developed for detection of various biochemical contaminants on medical device surfaces. We demonstrated the sensitivity of FO-FTIR-GIA sensing approach for non-contact and label-free detection of contaminants such as lipopolysaccharide from various surface materials relevant to medical device. The proposed sensing system can detect at a minimum loading concentration of approximately 0.7 μg/cm{sup 2}. The FO-FTIR-GIA has the potential for the detection of unwanted pathogen in real time.

  14. BORDERLINE AND CLASSIFICATION IN THE COMMUNITY REGULATORY FRAMEWORK FOR MEDICAL DEVICES – BRIEF REVIEW ON SOME DENTISTRY PRODUCTS.

    Directory of Open Access Journals (Sweden)

    Maya Lyapina

    2015-02-01

    Full Text Available Defining a given product as a medical device and interpretation of the application of the classification rules fall within the competence of the competent authorities of the Member States where the product is on the market. Different interpretations of Community legislation occur, and, can put public health at risk and distort the internal market. Borderline cases are considered to be those cases where it is not clear from the outset whether a given product is a medical device, an in vitro diagnostic medical device, an active implantable medical device or not. Classification cases can be described as those cases where there exists a difficulty in the uniform application of the classification rules as laid down in the Medical Devices Directive (MDD, or where for a given device, depending on interpretation of the rules, different classifications can occur. The aim of the present work is to make a brief review on discussion on classification in the community regulatory framework for medical devices of some dentistry products.

  15. The Biological Responses to Magnesium-Based Biodegradable Medical Devices

    Directory of Open Access Journals (Sweden)

    Lumei Liu

    2017-11-01

    Full Text Available The biocompatibility of Magnesium-based materials (MBMs is critical to the safety of biodegradable medical devices. As a promising metallic biomaterial for medical devices, the issue of greatest concern is devices’ safety as degrading products are possibly interacting with local tissue during complete degradation. The aim of this review is to summarize the biological responses to MBMs at the cellular/molecular level, including cell adhesion, transportation signaling, immune response, and tissue growth during the complex degradation process. We review the influence of MBMs on gene/protein biosynthesis and expression at the site of implantation, as well as throughout the body. This paper provides a systematic review of the cellular/molecular behavior of local tissue on the response to Mg degradation, which may facilitate a better prediction of long-term degradation and the safe use of magnesium-based implants through metal innovation.

  16. Modification of the surfaces of medical devices to prevent microbial adhesion and biofilm formation.

    Science.gov (United States)

    Desrousseaux, C; Sautou, V; Descamps, S; Traoré, O

    2013-10-01

    The development of devices with surfaces that have an effect against microbial adhesion or viability is a promising approach to the prevention of device-related infections. To review the strategies used to design devices with surfaces able to limit microbial adhesion and/or growth. A PubMed search of the published literature. One strategy is to design medical devices with a biocidal agent. Biocides can be incorporated into the materials or coated or covalently bonded, resulting either in release of the biocide or in contact killing without release of the biocide. The use of biocides in medical devices is debated because of the risk of bacterial resistance and potential toxicity. Another strategy is to modify the chemical or physical surface properties of the materials to prevent microbial adhesion, a complex phenomenon that also depends directly on microbial biological structure and the environment. Anti-adhesive chemical surface modifications mostly target the hydrophobicity features of the materials. Topographical modifications are focused on roughness and nanostructures, whose size and spatial organization are controlled. The most effective physical parameters to reduce bacterial adhesion remain to be determined and could depend on shape and other bacterial characteristics. A prevention strategy based on reducing microbial attachment rather than on releasing a biocide is promising. Evidence of the clinical efficacy of these surface-modified devices is lacking. Additional studies are needed to determine which physical features have the greatest potential for reducing adhesion and to assess the usefulness of antimicrobial coatings other than antibiotics. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  17. Communication during pediatric asthma visits and child asthma medication device technique 1 month later.

    Science.gov (United States)

    Sleath, Betsy; Carpenter, Delesha M; Ayala, Guadalupe X; Williams, Dennis; Davis, Stephanie; Tudor, Gail; Yeatts, Karin; Gillette, Chris

    2012-11-01

    This study investigated how provider demonstration of and assessment of child use of asthma medication devices and certain aspects of provider-patient communication during medical visits is associated with device technique 1 month later. Two hundred and ninety-six children aged 8-16 years with persistent asthma and their caregivers were recruited at five North Carolina pediatric practices. All of the medical visits were audio-tape recorded. Children were interviewed 1 month later and their device technique was observed and rated. If the provider asked the child to demonstrate metered dose inhaler technique during the medical visit, then the child was significantly more likely to perform a greater percentage of inhaler steps correctly 1 month later. Children with higher asthma management self-efficacy scores were significantly more likely to perform a greater percentage of diskus steps correctly. Additionally, children were significantly more likely to perform a greater percentage of diskus steps correctly if the provider discussed a written action plan during the visit. Children were significantly more likely to perform a greater percentage of turbuhaler steps correctly if they asked more medication questions. Providers should ask children to demonstrate their inhaler technique during medical visits so that they can educate children about proper technique and improve child asthma management self-efficacy. Providers should encourage children to ask questions about asthma medication devices during visits and they should discuss asthma action plans with families.

  18. French Sizing of Medical Devices is not Fit for Purpose

    International Nuclear Information System (INIS)

    Kibriya, Nabil; Hall, Rebecca; Powell, Steven; How, Thien; McWilliams, Richard G.

    2013-01-01

    PurposeThe purpose of the study is to quantify the variation in the metric equivalent of French size in a range of medical devices, from various manufacturers, used in interventional radiology.MethodsThe labelling of a range of catheters, introducers, drains, balloons, stents, and endografts was examined. Products were chosen to achieve a broad range of French sizes from several manufacturers. To assess manufacturing accuracy, eight devices were selected for measurement using a laser micrometer. The external diameters of three specimens of each device were measured at centimeter intervals along the length of the device to ensure uniformity.ResultsA total of 200 labels of interventional radiology equipment were scrutinized. The results demonstrate a wide variation in the metric equivalent of French sizing. Labelled products can vary in diameter across the product range by up to 0.79 mm.The devices selected for measurement with the non-contact laser micrometer demonstrate acceptable manufacturing consistency. The external diameter differed by 0.05 mm on average.ConclusionsOur results demonstrate wide variation in the interpretation of the French scale by different manufacturers of medical devices. This has the potential to lead to problems using coaxial systems especially when the products are from different manufacturers. It is recommended that standard labelling should be employed by all manufacturers conveying specific details of the equipment. Given the wide variation in the interpretation of the French scale, our opinion is that this scale either needs to be abandoned or be strictly defined and followed

  19. 77 FR 38177 - TRICARE; Off-Label Uses of Devices; Partial List of Examples of Unproven Drugs, Devices, Medical...

    Science.gov (United States)

    2012-06-27

    ... drugs, devices, and medical treatments or procedures and adding the TRICARE definition of unlabeled or... labeling. We are now modifying the definition of ``unlabeled or off-label drug'' to ``off-label use of a... reference back to the definition of the term in 199.2. ``Off-label uses of drugs and devices'' includes off...

  20. 75 FR 20854 - Medical Device Use in the Home Environment: Implications for the Safe and Effective Use of...

    Science.gov (United States)

    2010-04-21

    ...] Medical Device Use in the Home Environment: Implications for the Safe and Effective Use of Medical Device... related to the safe and effective use of medical device technology in the home environment. The workshop... the home environment. FDA will solicit feedback on: 1. The agency's current working definition of...

  1. Medical Device-Associated Candida Infections in a Rural Tertiary Care Teaching Hospital of India

    Directory of Open Access Journals (Sweden)

    Sachin C. Deorukhkar

    2016-01-01

    Full Text Available Health care associated infections (HCAIs add incrementally to the morbidity, mortality, and cost expected of the patient’s underlying diseases alone. Approximately, about half all cases of HCAIs are associated with medical devices. As Candida medical device-associated infection is highly drug resistant and can lead to serious life-threatening complications, there is a need of continuous surveillance of these infections to initiate preventive and corrective measures. The present study was conducted at a rural tertiary care hospital of India with an aim to evaluate the rate of medical device-associated Candida infections. Three commonly encountered medical device-associated infections (MDAI, catheter-associated urinary tract infection (CA-UTI, intravascular catheter-related blood stream infections (CR-BSI, and ventilator-associated pneumonia (VAP, were targeted. The overall rate of MDAI in our hospital was 2.1 per 1000 device days. The rate of Candida related CA-UTI and CR-BSI was noted as 1.0 and 0.3, respectively. Untiring efforts taken by team members of Hospital Acquired Infection Control Committee along with maintenance of meticulous hygiene of the hospital and wards may explain the low MDAI rates in our institute. The present surveillance helped us for systematic generation of institutional data regarding MDAI with special reference to role of Candida spp.

  2. 78 FR 56719 - Challenging Regulatory and Reimbursement Paradigms for Medical Devices in the Treatment of...

    Science.gov (United States)

    2013-09-13

    ...] Challenging Regulatory and Reimbursement Paradigms for Medical Devices in the Treatment of Metabolic Diseases... announcing a public workshop entitled ``Changing Regulatory and Reimbursement Paradigms for Medical Devices... registration information on the AGA Web site. If you need special accommodations due to a disability, please...

  3. Radiation as a microbiological contamination control of drugs, cosmetics and medical devices

    International Nuclear Information System (INIS)

    Ishizeki, Chuichi

    1985-01-01

    This paper deals with current status of radiation sterilization or disinfection of drugs, cosmetics, their materials, and medical devices, and with quality control as a tool for securing microbiological safety, especially current status of sterilization tests. Ointment containing tetracyclin, steroid hormones, gelatin, and enzymes are presented as drug samples to be irradiated, and explanations for radiation sterilization of these drugs are provided. An outline of the application of radiation in cosmetics and medical devices is given. Issues are also provided from the viewpoint of safey and effectiveness of radiation sterilization. (Namekawa, K.)

  4. [Intelligent telemedicine in intensive care units. Bed-side operation of medical technology devices and IT in intensive care medicine].

    Science.gov (United States)

    Röhrig, R; Rüth, R

    2009-03-01

    Patient data management systems (PDMS) may improve the quality of clinical documentation in intensive care medicine. In addition to the documentation, many PDMS offer the clinicians support for clinical decisions and workflow. The data recorded by the PDMS are available for data analysis to support administrative responsibilities (e.g., reimbursement, personnel management, quality management) or scientific questions. Within this process, semantic interoperability is a cornerstone for the integration of the PDMS into the IT infrastructure of the hospital, and the connection of medical devices is an essential precondition. Thus, a medical terminology system, like LOINC or SNOMED CT, is required, but are generally not widely used. This is partly caused by the fact that the effort necessary to implement a standard vocabulary is not equally shared between the sending and receiving systems. The solution could be medical devices that send LOINC-coded data. The experience of implementing LOINC into medical devices and information systems teaches us that more research and development of new functionalities for clinical information systems and PDMS to display and process (LOINC) coded data are needed.

  5. Real-time signal processing of accelerometer data for wearable medical patient monitoring devices.

    Science.gov (United States)

    Van Wieringen, Matt; Eklund, J

    2008-01-01

    Elderly and other people who live at home but required some physical assistance to do so are often more susceptible injury causing falls in and around their place of residence. In the event that a fall does occur, as a direct result of a previous medical condition or the fall itself, these people are typically less likely to be able to seek timely medical help without assistance. The goal of this research is to develop a wearable sensor device that uses an accelerometer for monitoring the movement of the person to detect falls after they have occurred in order to enable timely medical assistance. The data coming from the accelerometer is processed in real-time in the device and sent to a remote monitoring station where operators can attempt to make contact with the person and/or notify medical personnel of the situation. The ADXL330 accelerometer is contained within a Nintendo WiiMote controller, which forms the basis of the wearable medical sensor. The accelerometer data can then be sent via Bluetooth connection and processed by a local gateway processor. If a fall is detected, the gateway will then contact a remote monitoring station, on a cellular network, for example, via satellite, and/or through a hardwired phone or Internet connection. To detect the occurrence of ta fall, the accelerometer data is passed through a matched filter and the data is compared to benchmark analysis data that will define the conditions that represents the occurrence of a fall.

  6. Limited Awareness of the Essences of Certification or Compliance Markings on Medical Devices.

    Science.gov (United States)

    Foo, Jong Yong Abdiel; Tan, Xin Ji Alan

    2017-06-01

    Medical devices have been long used for odiagnostic, therapeutic or rehabilitation purposes. Currently, they can range from a low-cost portable device that is often used for personal health monitoring to high-end sophisticated equipment that can only be operated by trained professionals. Depending on the functional purposes, there are different certification or compliance markings on the device when it is sold. One common certification marking is the Conformité Européenne affixation but this has a range of certification mark numbering for a variety of functional purposes. While the regulators and medical device manufacturers understand the associated significance and clinical implications, these may not be apparent to the professionals (using or maintaining the device) and the general public. With portable healthcare devices and mobile applications gaining popularity, better awareness of certification marking will be needed. Particularly, there are differences in the allowed functional purposes and the associated cost derivations of devices with a seemingly similar nature. A preferred approach such as an easy-to-understand notation next to any certification marking on a device can aid in differentiation without the need to digest mountainous regulatory details.

  7. Feasibility of energy harvesting techniques for wearable medical devices.

    Science.gov (United States)

    Voss, Thaddaeus J; Subbian, Vignesh; Beyette, Fred R

    2014-01-01

    Wearable devices are arguably one of the most rapidly growing technologies in the computing and health care industry. These systems provide improved means of monitoring health status of humans in real-time. In order to cope with continuous sensing and transmission of biological and health status data, it is desirable to move towards energy autonomous systems that can charge batteries using passive, ambient energy. This not only ensures uninterrupted data capturing, but could also eliminate the need to frequently remove, replace, and recharge batteries. To this end, energy harvesting is a promising area that can lead to extremely power-efficient portable medical devices. This paper presents an experimental prototype to study the feasibility of harvesting two energy sources, solar and thermoelectric energy, in the context of wearable devices. Preliminary results show that such devices can be powered by transducing ambient energy that constantly surrounds us.

  8. Dosimetric studies for gamma radiation validation of medical devices

    International Nuclear Information System (INIS)

    Soliman, Y.S.; Beshir, W.B.; Abdel-Fattah, A.A.; Abdel-Rehim, F.

    2013-01-01

    The delivery and validation of a specified dose to medical devices are key concerns to operators of gamma radiation facilities. The objective of the present study was to characterize the industrial gamma radiation facility and map the dose distribution inside the product-loading pattern during the validation and routine control of the sterilization process using radiochromic films. Cardboard phantoms were designed to achieve the homogeneity of absorbed doses. The uncertainty of the dose delivered during validation of the sterilization process was assessed. - Highlights: ► Using γ-rays for sterilization of hollow fiber dialyzers and blood tubing sets according to ISO 11137, 2006. ► Dosimetry studies of validations of γ-irradiation facility and sterilized medical devices. ► Places of D min and D max have been determined using FWT-60 films. ► Determining the target minimum doses required to meet the desired SAL of 10 −6 for the two products.

  9. Fiber-optic Fourier transform infrared spectroscopy for remote label-free sensing of medical device surface contamination

    Science.gov (United States)

    Hassan, Moinuddin; Tan, Xin; Welle, Elissa; Ilev, Ilko

    2013-05-01

    As a potential major source of biochemical contamination, medical device surfaces are of critical safety concerns in the clinical practice and public health. The development of innovative sensing methods for accurate and real-time detection of medical device surface contamination is essential to protect patients from high risk infection. In this paper, we demonstrate an alternative fiber-optic Fourier Transform Infrared (FTIR) spectroscopy based sensing approach for remote, non-contact, and label-free detection of biochemical contaminants in the mid-infrared (mid-IR) region. The sensing probe is designed using mid-IR hollow fibers and FTIR measurements are carried out in reflection mode. Bovine Serum Albumin (BSA) and bacterial endotoxin of different concentrations under thoroughly dry condition are used to evaluate the detection sensitivity. The devised system can identify ≤0.0025% (≤4 × 1011 molecules) BSA and 0.5% (0.5 EU/ml) endotoxin concentration. The developed sensing approach may be applied to detect various pathogens that pose public health threats.

  10. Do single-use medical devices containing biopolymers reduce the environmental impacts of surgical procedures compared with their plastic equivalents?

    Science.gov (United States)

    Unger, Scott R; Hottle, Troy A; Hobbs, Shakira R; Thiel, Cassandra L; Campion, Nicole; Bilec, Melissa M; Landis, Amy E

    2017-01-01

    Background While petroleum-based plastics are extensively used in health care, recent developments in biopolymer manufacturing have created new opportunities for increased integration of biopolymers into medical products, devices and services. This study compared the environmental impacts of single-use disposable devices with increased biopolymer content versus typically manufactured devices in hysterectomy. Methods A comparative life cycle assessment of single-use disposable medical products containing plastic(s) versus the same single-use medical devices with biopolymers substituted for plastic(s) at Magee-Women's Hospital (Magee) in Pittsburgh, PA and the products used in four types of hysterectomies that contained plastics potentially suitable for biopolymer substitution. Magee is a 360-bed teaching hospital, which performs approximately 1400 hysterectomies annually. Results There are life cycle environmental impact tradeoffs when substituting biopolymers for petroplastics in procedures such as hysterectomies. The substitution of biopolymers for petroleum-based plastics increased smog-related impacts by approximately 900% for laparoscopic and robotic hysterectomies, and increased ozone depletion-related impacts by approximately 125% for laparoscopic and robotic hysterectomies. Conversely, biopolymers reduced life cycle human health impacts, acidification and cumulative energy demand for the four hysterectomy procedures. The integration of biopolymers into medical products is correlated with reductions in carcinogenic impacts, non-carcinogenic impacts and respiratory effects. However, the significant agricultural inputs associated with manufacturing biopolymers exacerbate environmental impacts of products and devices made using biopolymers. Conclusions The integration of biopolymers into medical products is correlated with reductions in carcinogenic impacts, non-carcinogenic impacts and respiratory effects; however, the significant agricultural inputs associated

  11. Field Safety Notes in Product Problems of Medical Devices for Use in Pulmonology.

    Science.gov (United States)

    Hannig, Jürgen; Siekmeier, Rüdiger

    2015-01-01

    The current European system for medical devices is governed by three EC directives: the Medical Device Directive 93/42/EEC, the In-Vitro Diagnostic Directive 98/79/EC and the Active Implantable Medical Device Directive 90/385/EEC and regulates marketing and post-market surveillance of medical devices in the European Economic Area. In cases of incidents and field safety corrective actions (FSCA) manufacturers have to inform the responsible Competent Authority, which is the Federal Institute for Drugs and Medical Devices (BfArM) and the public by field safety notices (FSN). In this study we analyzed FSN of medical devices exclusively serving for diagnostics or treatment in pulmonology (e.g. nebulizers, oxygen concentrators, pulse oximeters, lung function analyzers, and non-active devices for treatment). FSCA and FSN publicized by BfArM in 2005-2013 were analyzed in respect to the MEDDEV 2.12-1 rev 8. In total 41 FSCA were publicized for the included products. German and English FSN were found in 36/35 cases, respectively. FSN were clearly characterized as FSN in 22/20 cases and declaration of the type of action was found in 27/26 cases, respectively. Product names were provided in all cases. Lot numbers or other information for product characterization were available in 7/8 and 26/24 cases, respectively. Detailed information regarding FSCA and product malfunction were found in 27/33 and 36/35 cases, respectively. Information on product related risks with previous use of the affected product was provided in 24/23 cases. In 34/34 cases manufacturers provided information to mitigate product related risks. Requests to pass FSN to persons needing awareness were found in 10/14 cases. Contact data were provided in 30/30 cases. Confirmation that the Competent Authority was informed was found in 12/14 cases and in 19/18 cases a customer confirmation was included. The obtained data suggest that there is an increasing annual number of FSCA and most FSN fulfill the criteria of

  12. Regulation and Device Development: Tips for Optimizing Your Experience With the Food and Drug Administration.

    Science.gov (United States)

    Brooks, Steven S

    2017-06-01

    Physician-inventors are in a unique position to identify unserved patient needs, and innovate solutions to clinical problems. These solutions may also have associated commercial opportunities. The logistics of developing these medical products, however, can seem a daunting task. One of the primary barriers in the United States is the regulatory process of the Food and Drug Administration (FDA). In this article, we will explore the risk-based approach used by the FDA which forms a framework to consider the regulatory pathway and the process to gain regulatory clearance or approval for medical devices. Inherent device properties and the procedural risk of the devices will determine the rigor with which they are scrutinized by FDA, and the evidentiary requirements to legally market them. Data and evidentiary development will vary depending on risk and regulatory precedent and may or may not require clinical data This regulatory paradigm will determine into which risk-based device class they fit, and whether they are regulated under the 510(k) or premarket approval application pathways. The FDA, although gatekeeper of the US market and tasked with determining which products are safe and effective, can be a powerful ally for product development. They have significant scientific and medical expertise, and mechanisms to both provide guidance, and also to consider novel approaches to product development and evidence development. Early interaction for routine and novel products alike can result in expedited and efficient development. This collaborative approach can be best practice to most expeditiously develop the next generation of products, getting them into the hands of US doctors and into the treatment of US patients. Copyright © 2017. Published by Elsevier Inc.

  13. Understanding the mobile internet to develop the next generation of online medical teaching tools.

    Science.gov (United States)

    Desai, Tejas; Christiano, Cynthia; Ferris, Maria

    2011-01-01

    Healthcare providers (HCPs) use online medical information for self-directed learning and patient care. Recently, the mobile internet has emerged as a new platform for accessing medical information as it allows mobile devices to access online information in a manner compatible with their restricted storage. We investigated mobile internet usage parameters to direct the future development of mobile internet teaching websites. Nephrology On-Demand Mobile (NOD(M)) (http://www.nephrologyondemand.org) was made accessible to all mobile devices. From February 1 to December 31, 2010, HCP use of NOD(M) was tracked using code inserted into the root files. Nephrology On-Demand received 15,258 visits, of which approximately 10% were made to NOD(M), with the majority coming from the USA. Most access to NOD(M) was through the Apple iOS family of devices and cellular connections were the most frequently used. These findings provide a basis for the future development of mobile nephrology and medical teaching tools.

  14. Mobile Software as a Medical Device (SaMD) for the Treatment of Epilepsy: Development of Digital Therapeutics Comprising Behavioral and Music-Based Interventions for Neurological Disorders.

    Science.gov (United States)

    Afra, Pegah; Bruggers, Carol S; Sweney, Matthew; Fagatele, Lilly; Alavi, Fareeha; Greenwald, Michael; Huntsman, Merodean; Nguyen, Khanhly; Jones, Jeremiah K; Shantz, David; Bulaj, Grzegorz

    2018-01-01

    Digital health technologies for people with epilepsy (PWE) include internet-based resources and mobile apps for seizure management. Since non-pharmacological interventions, such as listening to specific Mozart's compositions, cognitive therapy, psychosocial and educational interventions were shown to reduce epileptic seizures, these modalities can be integrated into mobile software and delivered by mobile medical apps as digital therapeutics. Herein, we describe: (1) a survey study among PWE about preferences to use mobile software for seizure control, (2) a rationale for developing digital therapies for epilepsy, (3) creation of proof-of-concept mobile software intended for use as an adjunct digital therapeutic to reduce seizures, and (4) broader applications of digital therapeutics for the treatment of epilepsy and other chronic disorders. A questionnaire was used to survey PWE with respect to preferred features in a mobile app for seizure control. Results from the survey suggested that over 90% of responders would be interested in using a mobile app to manage their seizures, while 75% were interested in listening to specific music that can reduce seizures. To define digital therapeutic for the treatment of epilepsy, we designed and created a proof-of-concept mobile software providing digital content intended to reduce seizures. The rationale for all components of such digital therapeutic is described. The resulting web-based app delivered a combination of epilepsy self-care, behavioral interventions, medication reminders and the antiseizure music, such as the Mozart's sonata K.448. To improve long-term patient engagement, integration of mobile medical app with music and multimedia streaming via smartphones, tablets and computers is also discussed. This work aims toward development and regulatory clearance of software as medical device (SaMD) for seizure control, yielding the adjunct digital therapeutic for epilepsy, and subsequently a drug-device combination

  15. Power Factor Improvement Using Automatic Power Factor Compensation (APFC Device for Medical Industries in Malaysia

    Directory of Open Access Journals (Sweden)

    Zaidi Maryam Nabihah

    2018-01-01

    Full Text Available This paper present the project designed to correcting power factor for medical industries in Malaysia automatically. Which with hope to make the cost and energy usage efficient, because the energy source are depleting due to increase in population. Power factor is the ratio of real power and apparent power. This definition is mathematically represented as kW/kVA where kW is active power and kVA is apparent power (active + reactive. Reactive power is the non-working power generated by the magnetic and inductive load to generate magnetic flux. The increase in reactive power increase the apparent power so the power factor will decrease. Low pF will cause the industry to meet high demand thus making it less efficient. The main aim of this project is to increasing the current power factor of medical industries from 0.85 to 0.90. Power factor compensation contribute to reduction in current-dependent losses and increase energy efficiency while expanding the reliability of planning for future energy network. As technology develops, the gradual cost and efficiency penalty should reduce. Therefore, automatic power factor compensation device should become cost-effective and smaller device over time. That is the reason this project is using programmable device as it is a miniature architecture device.

  16. Monitoring of biofilm formation on different material surfaces of medical devices using hyperspectral imaging method

    Science.gov (United States)

    Kim, Do-Hyun; Kim, Moon S.; Hwang, Jeeseong

    2012-03-01

    Contamination of the inner surface of indwelling (implanted) medical devices by microbial biofilm is a serious problem. Some microbial bacteria such as Escherichia coli form biofilms that lead to potentially lifethreatening infections. Other types of medical devices such as bronchoscopes and duodenoscopes account for the highest number of reported endoscopic infections where microbial biofilm is one of the major causes for these infections. We applied a hyperspectral imaging method to detect biofilm contamination on the surface of several common materials used for medical devices. Such materials include stainless steel, titanium, and stainless-steeltitanium alloy. Potential uses of hyperspectral imaging technique to monitor biofilm attachment to different material surfaces are discussed.

  17. State of the art of medical devices featuring smart electro-rheological and magneto-rheological fluids

    Directory of Open Access Journals (Sweden)

    Jong-Seok Oh

    2017-10-01

    Full Text Available Recently, smart fluids have drawn significant attention and growing a great interest in a broad range of engineering applications such as automotive and medical areas. In this article, two smart fluids called electro-rheological (ER fluid and magneto-rheological (MR fluid are reviewed in terms of medical applications. Especially, this article describes the attributes and inherent properties of individual medical and rehabilitation devices. The devices surveyed in this article include multi-degree-of-freedom haptic masters for robot surgery, thin membrane touch panels for braille readers, sponge-like tactile sensors to feel human tissues such as liver, rehabilitation systems such as prosthetic leg, and haptic interfaces for dental implant surgery. The operating principle, inherent characteristics and practical feasibility of each medical device or system are fully discussed in details.

  18. Remote Access: A Vision for Mobile Medical Devices

    Directory of Open Access Journals (Sweden)

    Herbert Ernst

    2005-11-01

    Full Text Available During the Symposium for Remote Engineering and Virtual Instrumentation held at Brasov in early July 2005 an outlook was presented regarding the future potential of remote engineering for mobile medical devices. It is the intention of this article to recapitulate the content of the initiated discussions and to stimulate work in this complex and until now largely neglected field of application.

  19. Post-market clinical research conducted by medical device manufacturers: a cross-sectional survey

    Directory of Open Access Journals (Sweden)

    Ross JS

    2015-05-01

    Full Text Available Joseph S Ross, Katrina L Blount, Jessica D Ritchie, Beth Hodshon, Harlan M Krumholz Center for Outcomes Research and Evaluation, Yale-New Haven Hospital, New Haven, CT, USA Background: In the US, once a medical device is made available for use, several requirements have been established by the US Food and Drug Administration (FDA to ensure ongoing post-market surveillance of device safety and effectiveness. Our objective was to determine how commonly medical device manufacturers initiate post-market clinical studies or augment FDA post-market surveillance requirements for higher-risk devices that are most often approved via the FDA's pre-market approval (PMA pathway. Methods and results: We conducted a cross-sectional survey of 47 manufacturers with operations in California, Minnesota, and Massachusetts who market devices approved via the PMA pathway. Among 22 respondents (response rate =47%, nearly all self-reported conducting post-market clinical research studies, commonly between 1 and 5; only 1 respondent reported never conducting post-market clinical research studies. While manufacturers most often engaged in these studies to satisfy FDA requirements, other reasons were reported, including performance monitoring and surveillance and market acceptance initiatives. Risks of conducting and not conducting post-market clinical research studies were described through open-ended response to questions. Conclusion: Medical device manufacturers commonly initiate post-market clinical studies at the request of the FDA. Clinical data from these studies should be integrated into national post-market surveillance initiatives. Keywords: FDA, PMA pathway, post-market surveillance

  20. 21 CFR 801.125 - Medical devices for use in teaching, law enforcement, research, and analysis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical devices for use in teaching, law enforcement, research, and analysis. 801.125 Section 801.125 Food and Drugs FOOD AND DRUG ADMINISTRATION... Directions for Use § 801.125 Medical devices for use in teaching, law enforcement, research, and analysis. A...

  1. [Radiotherapy and implantable medical device: example of infusion pumps].

    Science.gov (United States)

    Abrous-Anane, S; Benhassine, S; Lopez, S; Cristina, K; Mazeron, J-J

    2013-12-01

    Indication for radiotherapy is often questioned for patients equipped with implantable medical devices like infusion pumps as the radiation tolerance is poor or not known. We report here on the case of a patient who we treated with pelvic radiotherapy for cervical cancer and who had an infusion pump in iliac fossa. We conducted a series of tests on five identical pumps that insured that the treatment protocol is harmless to the implanted device. Copyright © 2013 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  2. Biomedical devices and systems security.

    Science.gov (United States)

    Arney, David; Venkatasubramanian, Krishna K; Sokolsky, Oleg; Lee, Insup

    2011-01-01

    Medical devices have been changing in revolutionary ways in recent years. One is in their form-factor. Increasing miniaturization of medical devices has made them wearable, light-weight, and ubiquitous; they are available for continuous care and not restricted to clinical settings. Further, devices are increasingly becoming connected to external entities through both wired and wireless channels. These two developments have tremendous potential to make healthcare accessible to everyone and reduce costs. However, they also provide increased opportunity for technology savvy criminals to exploit them for fun and profit. Consequently, it is essential to consider medical device security issues. In this paper, we focused on the challenges involved in securing networked medical devices. We provide an overview of a generic networked medical device system model, a comprehensive attack and adversary model, and describe some of the challenges present in building security solutions to manage the attacks. Finally, we provide an overview of two areas of research that we believe will be crucial for making medical device system security solutions more viable in the long run: forensic data logging, and building security assurance cases.

  3. A prospective window into medical device-related pressure ulcers in intensive care.

    Science.gov (United States)

    Coyer, Fiona M; Stotts, Nancy A; Blackman, Virginia Schmied

    2014-12-01

    The aim of this study was to determine the prevalence, severity, location, aetiology, treatment and healing of medical device-related pressure ulcers (PUs) in intensive care patients for up to 7 days. A prospective repeated measures study design was used. Patients in six intensive care units of two major medical centres, one each in Australia and the USA, were screened 1 day per month for 6 months. Those with device-related ulcers were followed daily for up to 7 days. The outcome measures were device-related ulcer prevalence, pain, infection, treatment and healing. Fifteen of 483 patients had device-related ulcers and 9 of 15 with 11 ulcers were followed beyond screening. Their mean age was 60·5 years, and most were men, overweight and at increased risk of PU. Endotracheal (ET) and nasogastric (NG) tubes were the cause of most device-related ulcers. Repositioning was the most frequent treatment. Four of 11 ulcers healed within the 7-day observation period. In conclusion, device-related ulcer prevalence was 3·1%, similar to that reported in the limited literature available, indicating an ongoing problem. Systematic assessment and repositioning of devices are the mainstays of care. We recommend continued prevalence determination and that nurses remain vigilant to prevent device-related ulcers, especially in patients with NG and ET tubes. © 2013 The Authors. International Wound Journal © 2013 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  4. On-line integration of computer controlled diagnostic devices and medical information systems in undergraduate medical physics education for physicians.

    Science.gov (United States)

    Hanus, Josef; Nosek, Tomas; Zahora, Jiri; Bezrouk, Ales; Masin, Vladimir

    2013-01-01

    We designed and evaluated an innovative computer-aided-learning environment based on the on-line integration of computer controlled medical diagnostic devices and a medical information system for use in the preclinical medical physics education of medical students. Our learning system simulates the actual clinical environment in a hospital or primary care unit. It uses a commercial medical information system for on-line storage and processing of clinical type data acquired during physics laboratory classes. Every student adopts two roles, the role of 'patient' and the role of 'physician'. As a 'physician' the student operates the medical devices to clinically assess 'patient' colleagues and records all results in an electronic 'patient' record. We also introduced an innovative approach to the use of supportive education materials, based on the methods of adaptive e-learning. A survey of student feedback is included and statistically evaluated. The results from the student feedback confirm the positive response of the latter to this novel implementation of medical physics and informatics in preclinical education. This approach not only significantly improves learning of medical physics and informatics skills but has the added advantage that it facilitates students' transition from preclinical to clinical subjects. Copyright © 2011 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  5. Utilizing national and international registries to enhance pre-market medical device regulatory evaluation.

    Science.gov (United States)

    Yue, Lilly Q; Campbell, Gregory; Lu, Nelson; Xu, Yunling; Zuckerman, Bram

    2016-01-01

    Regulatory decisions are made based on the assessment of risk and benefit of medical devices at the time of pre-market approval and subsequently, when post-market risk-benefit balance needs reevaluation. Such assessments depend on scientific evidence obtained from pre-market studies, post-approval studies, post-market surveillance studies, patient perspective information, as well as other real world data such as national and international registries. Such registries provide real world evidence and are playing a more and more important role in enhancing the safety and effectiveness evaluation of medical devices. While these registries provide large quantities of data reflecting real world practice and can potentially reduce the cost of clinical trials, challenges arise concerning (1) data quality adequate for regulatory decision-making, (2) bias introduced at every stage and aspect of study, (3) scientific validity of study designs, and (4) reliability and interpretability of study results. This article will discuss related statistical and regulatory challenges and opportunities with examples encountered in medical device regulatory reviews.

  6. Biofilm eradication and prevention: a pharmaceutical approach to medical device infections

    National Research Council Canada - National Science Library

    Shunmugaperumal, Tamilvanan

    2010-01-01

    "Biofilm Eradication and Preventions presents the basics of biofilm formation on medical devices, diseases related to this formation, and approaches pharmaceutical researchers need to take to limit this problem...

  7. [Medical technology and medical education].

    Science.gov (United States)

    von Mallek, D; Biersack, H-J; Mull, R; Wilhelm, K; Heinz, B; Mellert, F

    2010-08-01

    The education of medical professionals is divided into medical studies, postgraduate training leading to the qualification as a specialist, and continuing professional development. During education, all scientific knowledge and practical skills are to be acquired, which enable the physician to practice responsibly in a specialized medical area. In the present article, relevant curricula are analyzed regarding the consideration of medical device-related topics, as the clinical application of medical technology has reached a central position in modern patient care. Due to the enormous scientific and technical progress, this area has become as important as pharmacotherapy. Our evaluation shows that medical device-related topics are currently underrepresented in the course of medical education and training and should be given greater consideration in all areas of medical education. Possible solutions are presented.

  8. Legislative and ethical aspects of introducing new technologies in medical care for senior citizens in developed countries

    Directory of Open Access Journals (Sweden)

    Kacetl J

    2016-07-01

    Full Text Available Jaroslav Kacetl,1 Petra Maresova2 1Department of Applied Linguistics, 2Department of Economics, Faculty of Informatics and Management, University of Hradec Kralove, Hradec Kralove, Czech Republic Introduction: The majority of developed countries are currently experiencing demographic aging. The most frequently expressed concerns related to the changing age structure are the increased costs of social and medical care, a lack of labor force in the job market, and financial sustainability of the pension system. These concerns are often based on the pessimistic view of population aging. This view understands aging as a prolonged period of illness and suffering. On the other hand, optimists believe that a longer life span is a result of increased quality of life and better health care. The quality of life may be improved not only by medicaments, but also by rapidly developing area of medical devices, which allow better care for seniors in many areas.Aim: This contribution aims to assess the legislative environment and ethical questions related to the use of medical devices, especially medical devices, in medical care for senior citizens.Methods: The methods used in this study are literature reviews of legislative and ethical environment in the European Union (EU and the US.Results: Main findings of this study result from assessing the state of medical device regulations in Europe and the US. Namely, the US regulation seems to be better arranged, which is probably due to the fact that there is only one responsible body – the US Food and Drug Administration, which is responsible for all medical device regulations. On the other hand, in the EU, talks about new legislation are led by ministers from all the EU member states and it may take a long time before all the EU countries come to an agreement. Keywords: senior citizen, medical devices, legislation, ethical aspects

  9. 76 FR 34845 - Medical Devices; Ear, Nose, and Throat Devices; Classification of the Wireless Air-Conduction...

    Science.gov (United States)

    2011-06-15

    ... control by other users with a similar medical device. Exposure to non-ionizing radiation Wireless... relating to EMC and wireless technology and human exposure to non-ionizing radiation. Therefore, on March... electro magnetic compatibility (EMC) and safety of exposure to non-ionizing radiation; (2) Design...

  10. Closed-loop approach for situation awareness of medical devices and operating room infrastructure

    Directory of Open Access Journals (Sweden)

    Rockstroh Max

    2015-09-01

    Full Text Available In recent years, approaches for information and control integration in the digital operating room have emerged. A major step towards an intelligent operating room and a cooperative technical environment would be autonomous adaptation of medical devices and systems to the surgical workflow. The OR staff should be freed from information seeking and maintenance tasks. We propose a closed-loop concept integrating workflow monitoring, processing and (semi-automatic interaction to bridge the gap between OR integration of medical devices and workflow-related information management.

  11. Mobile Devices, Learning and Clinical Workplaces: Medical Student Use of Smartphones in Parisian Hospitals

    Science.gov (United States)

    Phelps, Megan; Scott, Karen M.; Chauffeté-Manillier, Martine; Lenne, Frédéric; Le Jeunne, Claire

    2017-01-01

    Mobile devices are ubiquitous worldwide, including in hospitals. "Just in time" learning provided by these devices is important for students. We investigated current use of, and learning with, smartphones and other mobile devices by medical students in Parisian hospitals. A survey with quantitative and qualitative items previously used…

  12. Microbiological Load Of Ethylene Oxide Sterilized Medical Devices And Its Elimination By Cobalt 60 Source

    International Nuclear Information System (INIS)

    Bashir, R.; Afroze, B.; Zulfiqar, H. F.; Saleem, R.; Saleem, F.; Aslam, F.; Naz, S.

    2016-01-01

    Objective: To determine the residing microbial flora of ethylene oxide (EtO) sterilized medical devices and optimization of safe dose of gamma radiation (Cobalt 60 source) for the complete elimination of microbial load. Study Design: Experimental study. Place and Duration of Study: Department of Biotechnology, Lahore College for Women University, Lahore, Pakistan from September 2014 to June 2015. Methodology: Thirty-six samples of EtO sterilized medical devices of same batch of three different companies were collected for this study. Isolation and enumeration of microbes were done by using different selective and differential media. Gram staining and biochemically characterization by API 20 (Bio Merieux, France) kit was done for identification of the microorganisms. The medical devices having high microbial load were sent to Pakistan Radiation Services (PARAS) for gamma irradiations at 3 different selected doses (20 KGy, 25 KGy, and 30 KGy). Result: Different types of Gram positive bacteria (Staphylococcus epidermidis, Staphylococcus aureus and Bacillus subtilis) were isolated from the EtO sterilized samples. Gram negative bacteria and fungi were not detected on these medical devices. Gamma irradiations Result showed that 30 KGy was optimized dose for complete elimination of microbial flora on endotracheal, Nelaton, and tracheostomy tubes. Conclusion: Gamma radiations (Co 60 source) effectively decontaminate the microbial flora on the equipment previously sterilized by the ethylene oxide gas; and 30 KGy is the optimized dose for all these medical devices. (author)

  13. Classroom to Clinic: Merging Education and Research to Efficiently Prototype Medical Devices.

    Science.gov (United States)

    Hanumara, Nevan C; Begg, Nikolai D; Walsh, Conor; Custer, David; Gupta, Rajiv; Osborn, Lynn R; Slocum, Alexander H

    2013-01-01

    Innovation in patient care requires both clinical and technical skills, and this paper presents the methods and outcomes of a nine-year, clinical-academic collaboration to develop and evaluate new medical device technologies, while teaching mechanical engineering. Together, over the course of a single semester, seniors, graduate students, and clinicians conceive, design, build, and test proof-of-concept prototypes. Projects initiated in the course have generated intellectual property and peer-reviewed publications, stimulated further research, furthered student and clinician careers, and resulted in technology licenses and start-up ventures.

  14. Analysis of liquid medication dose errors made by patients and caregivers using alternative measuring devices.

    Science.gov (United States)

    Ryu, Gyeong Suk; Lee, Yu Jeung

    2012-01-01

    Patients use several types of devices to measure liquid medication. Using a criterion ranging from a 10% to 40% variation from a target 5 mL for a teaspoon dose, previous studies have found that a considerable proportion of patients or caregivers make errors when dosing liquid medication with measuring devices. To determine the rate and magnitude of liquid medication dose errors that occur with patient/caregiver use of various measuring devices in a community pharmacy. Liquid medication measurements by patients or caregivers were observed in a convenience sample of community pharmacy patrons in Korea during a 2-week period in March 2011. Participants included all patients or caregivers (N = 300) who came to the pharmacy to buy over-the-counter liquid medication or to have a liquid medication prescription filled during the study period. The participants were instructed by an investigator who was also a pharmacist to select their preferred measuring devices from 6 alternatives (etched-calibration dosing cup, printed-calibration dosing cup, dosing spoon, syringe, dispensing bottle, or spoon with a bottle adapter) and measure a 5 mL dose of Coben (chlorpheniramine maleate/phenylephrine HCl, Daewoo Pharm. Co., Ltd) syrup using the device of their choice. The investigator used an ISOLAB graduated cylinder (Germany, blue grad, 10 mL) to measure the amount of syrup dispensed by the study participants. Participant characteristics were recorded including gender, age, education level, and relationship to the person for whom the medication was intended. Of the 300 participants, 257 (85.7%) were female; 286 (95.3%) had at least a high school education; and 282 (94.0%) were caregivers (parent or grandparent) for the patient. The mean (SD) measured dose was 4.949 (0.378) mL for the 300 participants. In analysis of variance of the 6 measuring devices, the greatest difference from the 5 mL target was a mean 5.552 mL for 17 subjects who used the regular (etched) dosing cup and 4

  15. Medical applications of superconducting quantum interference devices

    International Nuclear Information System (INIS)

    Uehara, Gen

    2011-01-01

    SQUIDs (Superconducting Quantum Interference Devices) are applied to clinical areas and basic medical science fields because of their potential for measuring a minute magnetic signal from the human body. Magnetoencephalography, one of their applications, is used for the functional mapping of the brain cortex before surgery and the localization of focus of epilepsy. Recently, their applications to the early-stage detection of dementia and the localization of brain ischemia are suggested. Another application of SQUIDs is magnetospinography, which detects the conduction block in spinal cord signal propagation. (author)

  16. 76 FR 18227 - Molecular and Clinical Genetics Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-04-01

    ...] Molecular and Clinical Genetics Panel of the Medical Devices Advisory Committee; Notice of Meeting... comment period for the notice announcing a meeting of the Molecular and Clinical Genetics Panel (the panel... Clinical Genetics Panel of the Medical Devices Advisory Committee, and the opening of a public docket to...

  17. Software-Related Recalls of Health Information Technology and Other Medical Devices: Implications for FDA Regulation of Digital Health.

    Science.gov (United States)

    Ronquillo, Jay G; Zuckerman, Diana M

    2017-09-01

    Policy Points: Medical software has become an increasingly critical component of health care, yet the regulation of these devices is inconsistent and controversial. No studies of medical devices and software assess the impact on patient safety of the FDA's current regulatory safeguards and new legislative changes to those standards. Our analysis quantifies the impact of software problems in regulated medical devices and indicates that current regulations are necessary but not sufficient for ensuring patient safety by identifying and eliminating dangerous defects in software currently on the market. New legislative changes will further deregulate health IT, reducing safeguards that facilitate the reporting and timely recall of flawed medical software that could harm patients. Medical software has become an increasingly critical component of health care, yet the regulatory landscape for digital health is inconsistent and controversial. To understand which policies might best protect patients, we examined the impact of the US Food and Drug Administration's (FDA's) regulatory safeguards on software-related technologies in recent years and the implications for newly passed legislative changes in regulatory policy. Using FDA databases, we identified all medical devices that were recalled from 2011 through 2015 primarily because of software defects. We counted all software-related recalls for each FDA risk category and evaluated each high-risk and moderate-risk recall of electronic medical records to determine the manufacturer, device classification, submission type, number of units, and product details. A total of 627 software devices (1.4 million units) were subject to recalls, with 12 of these devices (190,596 units) subject to the highest-risk recalls. Eleven of the devices recalled as high risk had entered the market through the FDA review process that does not require evidence of safety or effectiveness, and one device was completely exempt from regulatory review

  18. 47 CFR 95.1119 - Specific requirements for wireless medical telemetry devices operating in the 608-614 MHz band.

    Science.gov (United States)

    2010-10-01

    ... devices operating in the 608-614 MHz band. For a wireless medical telemetry device operating within the... 47 Telecommunication 5 2010-10-01 2010-10-01 false Specific requirements for wireless medical telemetry devices operating in the 608-614 MHz band. 95.1119 Section 95.1119 Telecommunication FEDERAL...

  19. [New medical device hospital assessment: what kind of clinical data?].

    Science.gov (United States)

    Beaussier, H; Junot, H; Lancrenon, S; Faure, P

    2012-01-01

    Since 2003, the AP-HP medical devices committee (CODIMS) assess the therapeutic relevance of innovated medical device (MD) for the French AP-HP hospitals' group. To accomplish this task, the CODIMS asks manufacturers to bring out clinical arguments to justify the use of their MD in hospital. This work analyses retrospectively after 8years, all assessed MD until March 2011 and the scientific quality of the clinical data submitted by manufacturers to the CODIMS to purchase their MD. All MD were classed according to their certification's level (I, IIa, IIb, III, DMIA). The quality of available clinical studies (CS) provided by manufacturers for each case was assessed and classed according to five clinical relevance levels based on the evidence-based medecine standards (1-2: high methodology; 3-5: low methodology). One hundred and three MD files (80 % of class IIb and III MD) were analysed by the CODIMS (630CS). Our results highlight the lack of relevance of files that are provided to assess innovated MD: 29 files without any CS; concerning class IIb (32DMS, 221CS) and III (50, 342CS) MD, only 6 % of CS presented a correct clinical relevance level. And the situation did not get better during this assessment period. The CODIMS deplore the poor clinical relevance of files provided to assess MD (wrong comparator, inappropriate ends-points, insufficient follow-up to assess long-term security, small population studied). Future legislative developments for MD assessment are expected to improve this situation. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  20. OpenICE medical device interoperability platform overview and requirement analysis.

    Science.gov (United States)

    Arney, David; Plourde, Jeffrey; Goldman, Julian M

    2018-02-23

    We give an overview of OpenICE, an open source implementation of the ASTM standard F2761 for the Integrated Clinical Environment (ICE) that leverages medical device interoperability, together with an analysis of the clinical and non-functional requirements and community process that inspired its design.

  1. Lessons learned: mobile device encryption in the academic medical center.

    Science.gov (United States)

    Kusche, Kristopher P

    2009-01-01

    The academic medical center is faced with the unique challenge of meeting the multi-faceted needs of both a modern healthcare organization and an academic institution, The need for security to protect patient information must be balanced by the academic freedoms expected in the college setting. The Albany Medical Center, consisting of the Albany Medical College and the Albany Medical Center Hospital, was challenged with implementing a solution that would preserve the availability, integrity and confidentiality of business, patient and research data stored on mobile devices. To solve this problem, Albany Medical Center implemented a mobile encryption suite across the enterprise. Such an implementation comes with complexities, from performance across multiple generations of computers and operating systems, to diversity of application use mode and end user adoption, all of which requires thoughtful policy and standards creation, understanding of regulations, and a willingness and ability to work through such diverse needs.

  2. 21 CFR 801.1 - Medical devices; name and place of business of manufacturer, packer or distributor.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical devices; name and place of business of manufacturer, packer or distributor. 801.1 Section 801.1 Food and Drugs FOOD AND DRUG ADMINISTRATION... § 801.1 Medical devices; name and place of business of manufacturer, packer or distributor. (a) The...

  3. Hydrophilic Polymer Embolism: Implications for Manufacturing, Regulation, and Postmarket Surveillance of Coated Intravascular Medical Devices.

    Science.gov (United States)

    Mehta, Rashi I; Mehta, Rupal I

    2018-03-19

    Hydrophilic polymers are ubiquitously applied as surface coatings on catheters and intravascular medical technologies. Recent clinical literature has heightened awareness on the complication of hydrophilic polymer embolism, the phenomenon wherein polymer coating layers separate from catheter and device surfaces, and may be affiliated with a range of unanticipated adverse reactions. Significant system barriers have limited and delayed reporting on this iatrogenic complication, the full effects of which remain underrecognized by healthcare providers and manufacturers of various branded devices. In 2015, the United States Food and Drug Administration acknowledged rising clinical concerns and stated that the agency would work with stakeholders to further evaluate gaps that exist in current national and international device standards for coated intravascular medical technologies. The present article reviews current knowledge on this complication as well as factors that played a role in delaying detection and dissemination of information and new knowledge once hazards and clinical risks were identified. Furthermore, organ-specific effects and adverse reaction patterns are summarized, along with implications for device manufacturing, safety assurance, and regulation. Qualitative and quantitative particulate testing are needed to optimize coated intravascular device technologies. Moreover, general enhanced processes for medical device surveillance are required for timely adverse event management and to ensure patient safety.

  4. Discovery and Development of Synthetic and Natural Biomaterials for Protein Therapeutics and Medical Device Applications

    Science.gov (United States)

    Keefe, Andrew J.

    Controlling nonspecific protein interactions is important for applications from medical devices to protein therapeutics. The presented work is a compilation of efforts aimed at using zwitterionic (ionic yet charge neutral) polymers to modify and stabilize the surface of sensitive biomedical and biological materials. Traditionally, when modifying the surface of a material, the stability of the underlying substrate. The materials modified in this dissertation are unique due to their unconventional amorphous characteristics which provide additional challenges. These are poly(dimethyl siloxane) (PDMS) rubber, and proteins. These materials may seem dissimilar, but both have amorphous surfaces, that do not respond well to chemical modification. PDMS is a biomaterial extensively used in medical device manufacturing, but experiences unacceptably high levels of non-specific protein fouling when used with biological samples. To reduce protein fouling, surface modification is often needed. Unfortunately conventional surface modification methods, such as Poly(ethylene glycol) (PEG) coatings, do not work for PDMS due to its amorphous state. Herein, we demonstrate how a superhydrophilic zwitterionic material, poly(carboxybetaine methacrylate) (pCBMA), can provide a highly stable nonfouling coating with long term stability due to the sharp the contrast in hydrophobicity between pCBMA and PDMS. Biological materials, such as proteins, also require stabilization to improve shelf life, circulation time, and bioactivity. Conjugation of proteins with PEG is often used to increase protein stability, but has a detrimental effect on bioactivity. Here we have shown that pCBMA conjugation improves stability in a similar fashion to PEG, but also retains, or even improves, binding affinity due to enhanced protein-substrate hydrophobic interactions. Recognizing that pCBMA chemically resembles the combination of lysine (K) and glutamic acid (E) amino acids, we have shown how zwitterionic

  5. MELLO: Medical lifelog ontology for data terms from self-tracking and lifelog devices.

    Science.gov (United States)

    Kim, Hye Hyeon; Lee, Soo Youn; Baik, Su Youn; Kim, Ju Han

    2015-12-01

    The increasing use of health self-tracking devices is making the integration of heterogeneous data and shared decision-making more challenging. Computational analysis of lifelog data has been hampered by the lack of semantic and syntactic consistency among lifelog terms and related ontologies. Medical lifelog ontology (MELLO) was developed by identifying lifelog concepts and relationships between concepts, and it provides clear definitions by following ontology development methods. MELLO aims to support the classification and semantic mapping of lifelog data from diverse health self-tracking devices. MELLO was developed using the General Formal Ontology method with a manual iterative process comprising five steps: (1) defining the scope of lifelog data, (2) identifying lifelog concepts, (3) assigning relationships among MELLO concepts, (4) developing MELLO properties (e.g., synonyms, preferred terms, and definitions) for each MELLO concept, and (5) evaluating representative layers of the ontology content. An evaluation was performed by classifying 11 devices into 3 classes by subjects, and performing pairwise comparisons of lifelog terms among 5 devices in each class as measured using the Jaccard similarity index. MELLO represents a comprehensive knowledge base of 1998 lifelog concepts, with 4996 synonyms for 1211 (61%) concepts and 1395 definitions for 926 (46%) concepts. The MELLO Browser and MELLO Mapper provide convenient access and annotating non-standard proprietary terms with MELLO (http://mello.snubi.org/). MELLO covers 88.1% of lifelog terms from 11 health self-tracking devices and uses simple string matching to match semantically similar terms provided by various devices that are not yet integrated. The results from the comparisons of Jaccard similarities between simple string matching and MELLO matching revealed increases of 2.5, 2.2, and 5.7 folds for physical activity,body measure, and sleep classes, respectively. MELLO is the first ontology for

  6. Value-based procurement of medical devices: Application to devices for mechanical thrombectomy in ischemic stroke.

    Science.gov (United States)

    Trippoli, Sabrina; Caccese, Erminia; Marinai, Claudio; Messori, Andrea

    2018-03-01

    In the acute ischemic stroke, endovascular devices have shown promising clinical results and are also likely to represent value for money, as several modeling studies have shown. Pharmacoeconomic evaluations in this field, however, have little impact on the procurement of these devices. The present study explored how complex pharmacoeconomic models that evaluate effectiveness and cost can be incorporated into the in-hospital procurement of thrombectomy devices. As regards clinical modeling, we extracted outcomes at three months from randomized trials conducted for four thrombectomy devices, and we projected long-term results using standard Markov modeling. In estimating QALYs, the same model was run for the four devices. As regards economic modeling, we firstly estimated for each device the net monetary benefit (NMB) per patient (threshold = $60,000 per QALY); then, we simulated a competitive tender across the four products by determining the tender-based score (on a 0-to-100 scale). Prices of individual devices were obtained from manufacturers. Extensive sensitivity testing was applied to our analyses. For the four devices (Solitaire, Trevo, Penumbra, Solumbra), QALYs were 1.86, 1.52, 1,79, 1.35, NMB was $101,824, $83,546, $101,923, $69,440, and tender-based scores were 99.70, 43.43, 100, 0, respectively. Sensitivity analysis confirmed findings from base-case. Our results indicate that, in the field of thrombectomy devices, incorporating the typical tools of cost-effectiveness into the processes of tenders and procurement is feasible. Bridging the methodology of cost-effectiveness with the every-day practice of in-hospital procurement can contribute to maximizing the health returns that are generated by in-hospital expenditures for medical devices. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Prevention of Medical Device-Related Pressure Injuries Associated With Respiratory Equipment Use in a Critical Care Unit: A Quality Improvement Project.

    Science.gov (United States)

    Padula, Cynthia A; Paradis, Heidi; Goodwin, Robert; Lynch, Judith; Hegerich-Bartula, Deborah

    Medical devices have been identified as an extrinsic risk factor for development of pressure injuries, with as many as 30% to 70% of medical device-related pressure injuries resulting from respiratory equipment. This article describes a quality improvement project undertaken to reduce the occurrence of respiratory device-related pressure injuries in a critically care unit. Multiple actions were implemented to achieve this goal. Respiratory therapists were trained to document occurrences on a daily basis, and apparent cause analyses were conducted on each occurrence. An interdisciplinary team conducted biweekly rounds on patients with respiratory devices and consulted other professionals as indicated. Nurses and respiratory therapists attended an evidence-based, collaborative, educational offering and completed a measure of team functioning before the program and at the end of the study period. The occurrence rates of respiratory device-related pressure injuries were reduced over the project period, and these changes were sustained over the subsequent 12 months.

  8. FDA (Food and Drug Administration) Compliance Program Guidance Manual (FY 88). Section 4. Medical and radiological devices

    International Nuclear Information System (INIS)

    1988-01-01

    The FDA Compliance Program Guidance Manual provides a system for issuing and filing program plans and instructions directed to Food and Drug Administration Field operations for project implementation. Section IV provides those chapters of the Compliance Program Guidance Manual which pertain to the areas of medical and radiological devices. Some of the areas of coverage include laser and sunlamp standards inspections, compliance testing of various radiation-emitting products such as television receivers and microwave ovens, emergency response planning and policy, premarket approval and device manufacturers inspections, device problem reporting, sterilization of devices, and consumer education programs on medical and radiological devices

  9. Pre-market approval and post-market direct-to-consumer advertising of medical devices in Australia: a case study of breast cancer screening and diagnostic devices.

    Science.gov (United States)

    Vreugdenburg, T D; Willis, C D; Mundy, L; Hiller, J E

    2013-01-01

    While research investigating direct-to-consumer advertising of therapeutic goods in Australia has historically focused on prescription medicines, recent action taken by regulators against companies promoting medical devices has placed the industry into the spotlight. Despite the need to effectively regulate direct-to-consumer advertising of medical devices due to its potential harms, inadequacies in the current regulatory system have been noted. Under the present system, devices with a questionable evidence base may enter the Australian marketplace without an evaluation of their effectiveness, and regulators are reliant on industry self-regulation and consumer complaints to draw attention to cases of advertising misconduct. Although some successes in the present system have been observed, we argue that the outlined inadequacies continue to enable the promotion of medical devices to consumers without thorough or sufficient examination of evidence. © 2011 The Authors; Internal Medicine Journal © 2011 Royal Australasian College of Physicians.

  10. First experiences with the implementation of the European standard EN 62304 on medical device software for the quality assurance of a radiotherapy unit.

    Science.gov (United States)

    Höss, Angelika; Lampe, Christian; Panse, Ralf; Ackermann, Benjamin; Naumann, Jakob; Jäkel, Oliver

    2014-03-21

    According to the latest amendment of the Medical Device Directive standalone software qualifies as a medical device when intended by the manufacturer to be used for medical purposes. In this context, the EN 62304 standard is applicable which defines the life-cycle requirements for the development and maintenance of medical device software. A pilot project was launched to acquire skills in implementing this standard in a hospital-based environment (in-house manufacture). The EN 62304 standard outlines minimum requirements for each stage of the software life-cycle, defines the activities and tasks to be performed and scales documentation and testing according to its criticality. The required processes were established for the pre-existent decision-support software FlashDumpComparator (FDC) used during the quality assurance of treatment-relevant beam parameters. As the EN 62304 standard implicates compliance with the EN ISO 14971 standard on the application of risk management to medical devices, a risk analysis was carried out to identify potential hazards and reduce the associated risks to acceptable levels. The EN 62304 standard is difficult to implement without proper tools, thus open-source software was selected and integrated into a dedicated development platform. The control measures yielded by the risk analysis were independently implemented and verified, and a script-based test automation was retrofitted to reduce the associated test effort. After all documents facilitating the traceability of the specified requirements to the corresponding tests and of the control measures to the proof of execution were generated, the FDC was released as an accessory to the HIT facility. The implementation of the EN 62304 standard was time-consuming, and a learning curve had to be overcome during the first iterations of the associated processes, but many process descriptions and all software tools can be re-utilized in follow-up projects. It has been demonstrated that a

  11. First experiences with the implementation of the European standard EN 62304 on medical device software for the quality assurance of a radiotherapy unit

    International Nuclear Information System (INIS)

    Höss, Angelika; Lampe, Christian; Panse, Ralf; Ackermann, Benjamin; Naumann, Jakob; Jäkel, Oliver

    2014-01-01

    According to the latest amendment of the Medical Device Directive standalone software qualifies as a medical device when intended by the manufacturer to be used for medical purposes. In this context, the EN 62304 standard is applicable which defines the life-cycle requirements for the development and maintenance of medical device software. A pilot project was launched to acquire skills in implementing this standard in a hospital-based environment (in-house manufacture). The EN 62304 standard outlines minimum requirements for each stage of the software life-cycle, defines the activities and tasks to be performed and scales documentation and testing according to its criticality. The required processes were established for the pre-existent decision-support software FlashDumpComparator (FDC) used during the quality assurance of treatment-relevant beam parameters. As the EN 62304 standard implicates compliance with the EN ISO 14971 standard on the application of risk management to medical devices, a risk analysis was carried out to identify potential hazards and reduce the associated risks to acceptable levels. The EN 62304 standard is difficult to implement without proper tools, thus open-source software was selected and integrated into a dedicated development platform. The control measures yielded by the risk analysis were independently implemented and verified, and a script-based test automation was retrofitted to reduce the associated test effort. After all documents facilitating the traceability of the specified requirements to the corresponding tests and of the control measures to the proof of execution were generated, the FDC was released as an accessory to the HIT facility. The implementation of the EN 62304 standard was time-consuming, and a learning curve had to be overcome during the first iterations of the associated processes, but many process descriptions and all software tools can be re-utilized in follow-up projects. It has been demonstrated that a

  12. 76 FR 6623 - Molecular and Clinical Genetics Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2011-02-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0066] Molecular and Clinical Genetics Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY... public. Name of Committee: Molecular and Clinical Genetics Panel of the Medical Devices Advisory...

  13. 21 CFR 801.128 - Exceptions or alternatives to labeling requirements for medical devices held by the Strategic...

    Science.gov (United States)

    2010-04-01

    ... requirements for medical devices held by the Strategic National Stockpile. 801.128 Section 801.128 Food and... requirements for medical devices held by the Strategic National Stockpile. (a) The appropriate FDA Center... Strategic National Stockpile. (b)(1)(i) A Strategic National Stockpile official or any entity that...

  14. Comparison of Transplant Waitlist Outcomes for Pediatric Candidates Supported by Ventricular Assist Devices Versus Medical Therapy.

    Science.gov (United States)

    Law, Sabrina P; Oron, Assaf P; Kemna, Mariska S; Albers, Erin L; McMullan, D Michael; Chen, Jonathan M; Law, Yuk M

    2018-05-01

    Ventricular assist devices have gained popularity in the management of refractory heart failure in children listed for heart transplantation. Our primary aim was to compare the composite endpoint of all-cause pretransplant mortality and loss of transplant eligibility in children who were treated with a ventricular assist device versus a medically managed cohort. This was a retrospective cohort analysis. Data were obtained from the Scientific Registry of Transplant Recipients. The at-risk population (n = 1,380) was less than 18 years old, either on a ventricular assist device (605 cases) or an equivalent-severity, intensively medically treated group (referred to as MED, 775 cases). None. The impact of ventricular assist devices was estimated via Cox proportional hazards regression (hazard ratio), dichotomizing 1-year outcomes to "poor" (22%: 193 deaths, 114 too sick) versus all others (940 successful transplants, 41 too healthy, 90 censored), while adjusting for conventional risk factors. Among children 0-12 months old, ventricular assist device was associated with a higher risk of poor outcomes (hazard ratio, 2.1; 95% CI, 1.5-3.0; p comparative study of ventricular assist devices versus medical therapy in children. Age is a significant modulator of waitlist outcomes for children with end-stage heart failure supported by ventricular assist device, with the impact of ventricular assist devices being more beneficial in adolescents.

  15. Development and examination of a rubric for evaluating point-of-care medical applications for mobile devices.

    Science.gov (United States)

    Butcher, Robyn; MacKinnon, Martin; Gadd, Kathleen; LeBlanc-Duchin, Denise

    2015-01-01

    The rapid development and updates of mobile medical resource applications (apps) highlight the need for an evaluation tool to assess the content of these resources. The purpose of the study was to develop and test a new evaluation rubric for medical resource apps. The evaluation rubric was designed using existing literature and through a collaborative effort between a hospital and an academic librarian. Testing found scores ranging from 23% to 88% for the apps. The evaluation rubric proved able to distinguish levels of quality within each content component of the apps, demonstrating potential for standardization of medical resource app evaluations.

  16. Regulation E 69-14. Monitoring requirements for medical devices

    International Nuclear Information System (INIS)

    2015-01-01

    In the 'Regulations for the State Evaluation and Registration of Medical Equipment' force (Hereinafter Rules) set forth in Chapter VII, Articles 79 and 86, the monitoring activity as one of the programs necessary for evaluating the safety and effectiveness of medical monitoring equipment. In the years 2008 and 2011 were approved and implemented by the Center for State Control of Medical Equipment (CCEEM) Regulations and -1.1 ER and ER-1 that support and regulatory requirements 'Control and monitoring of pacemakers and implantable defibrillators' and 'Assessment, recording and control after market surgical silicone implants,' which are specific to these products and have provided a useful result for the performance of the activity. Given the number and diversity of high-risk medical devices as implantable or sustain human life that are brought into our National Health System (SNS), a regulation establishing control over the behavior becomes necessary safety and effectiveness of this equipment during use, which provide inputs to risk management. The objective of this regulation is to establish the regulatory requirements for tracking medical equipment introduced in the NHS. The provisions of this Regulation is aimed at health institutions, to CECMED as manufacturers, suppliers, distributors and importers of medical equipment.

  17. An information model to support user-centered design of medical devices.

    Science.gov (United States)

    Hagedorn, Thomas J; Krishnamurty, Sundar; Grosse, Ian R

    2016-08-01

    The process of engineering design requires the product development team to balance the needs and limitations of many stakeholders, including those of the user, regulatory organizations, and the designing institution. This is particularly true in medical device design, where additional consideration must be given for a much more complex user-base that can only be accessed on a limited basis. Given this inherent challenge, few projects exist that consider design domain concepts, such as aspects of a detailed design, a detailed view of various stakeholders and their capabilities, along with the user-needs simultaneously. In this paper, we present a novel information model approach that combines a detailed model of design elements with a model of the design itself, customer requirements, and of the capabilities of the customer themselves. The information model is used to facilitate knowledge capture and automated reasoning across domains with a minimal set of rules by adopting a terminology that treats customer and design specific factors identically, thus enabling straightforward assessments. A uniqueness of this approach is that it systematically provides an integrated perspective on the key usability information that drive design decisions towards more universal or effective outcomes with the very design information impacted by the usability information. This can lead to cost-efficient optimal designs based on a direct inclusion of the needs of customers alongside those of business, marketing, and engineering requirements. Two case studies are presented to show the method's potential as a more effective knowledge management tool with built-in automated inferences that provide design insight, as well as its overall effectiveness as a platform to develop and execute medical device design from a holistic perspective. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. On a turbulent wall model to predict hemolysis numerically in medical devices

    Science.gov (United States)

    Lee, Seunghun; Chang, Minwook; Kang, Seongwon; Hur, Nahmkeon; Kim, Wonjung

    2017-11-01

    Analyzing degradation of red blood cells is very important for medical devices with blood flows. The blood shear stress has been recognized as the most dominant factor for hemolysis in medical devices. Compared to laminar flows, turbulent flows have higher shear stress values in the regions near the wall. In case of predicting hemolysis numerically, this phenomenon can require a very fine mesh and large computational resources. In order to resolve this issue, the purpose of this study is to develop a turbulent wall model to predict the hemolysis more efficiently. In order to decrease the numerical error of hemolysis prediction in a coarse grid resolution, we divided the computational domain into two regions and applied different approaches to each region. In the near-wall region with a steep velocity gradient, an analytic approach using modeled velocity profile is applied to reduce a numerical error to allow a coarse grid resolution. We adopt the Van Driest law as a model for the mean velocity profile. In a region far from the wall, a regular numerical discretization is applied. The proposed turbulent wall model is evaluated for a few turbulent flows inside a cannula and centrifugal pumps. The results present that the proposed turbulent wall model for hemolysis improves the computational efficiency significantly for engineering applications. Corresponding author.

  19. 21 CFR 610.42 - Restrictions on use for further manufacture of medical devices.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Restrictions on use for further manufacture of medical devices. 610.42 Section 610.42 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH... for Communicable Disease Agents § 610.42 Restrictions on use for further manufacture of medical...

  20. Design and development of a device to measure the deformities of clubfoot.

    Science.gov (United States)

    Khas, Kanwaljit S; Pandey, Pulak M; Ray, Alok R

    2015-03-01

    Clubfoot describes a range of foot abnormalities usually present at birth, in which the foot of a baby is twisted out of shape or position. In order to develop an effective treatment plan for clubfoot and/or assess the extent to which existing interventions are successful, medical practitioners need to be able to accurately measure the nature and extent of the deformity. This is typically performed using a goniometer. However, this device is only able to measure one dimension at a time. As such, a complete assessment of the condition of a foot can be extremely burdensome and time-consuming. This article describes a new device that can quickly and efficiently take several measurements on feet of various sizes and shapes. The use of this device was verified by measuring the deformities of real clubfeet. A silicone rubber clubfoot model was also used in this study to clearly illustrate the effectiveness with which the proposed device can measure the various deformities of clubfoot. It is envisaged that the use of this device will significantly reduce the time and effort orthopedists require to measure clubfoot deformities and develop and assess treatment plans. © IMechE 2015.

  1. Development of a mini-mobile digital radiography system by using wireless smart devices.

    Science.gov (United States)

    Jeong, Chang-Won; Joo, Su-Chong; Ryu, Jong-Hyun; Lee, Jinseok; Kim, Kyong-Woo; Yoon, Kwon-Ha

    2014-08-01

    The current technologies that trend in digital radiology (DR) are toward systems using portable smart mobile as patient-centered care. We aimed to develop a mini-mobile DR system by using smart devices for wireless connection into medical information systems. We developed a mini-mobile DR system consisting of an X-ray source and a Complementary Metal-Oxide Semiconductor (CMOS) sensor based on a flat panel detector for small-field diagnostics in patients. It is used instead of the systems that are difficult to perform with a fixed traditional device. We also designed a method for embedded systems in the development of portable DR systems. The external interface used the fast and stable IEEE 802.11n wireless protocol, and we adapted the device for connections with Picture Archiving and Communication System (PACS) and smart devices. The smart device could display images on an external monitor other than the monitor in the DR system. The communication modules, main control board, and external interface supporting smart devices were implemented. Further, a smart viewer based on the external interface was developed to display image files on various smart devices. In addition, the advantage of operators is to reduce radiation dose when using remote smart devices. It is integrated with smart devices that can provide X-ray imaging services anywhere. With this technology, it can permit image observation on a smart device from a remote location by connecting to the external interface. We evaluated the response time of the mini-mobile DR system to compare to mobile PACS. The experimental results show that our system outperforms conventional mobile PACS in this regard.

  2. MRI-powered biomedical devices.

    Science.gov (United States)

    Hovet, Sierra; Ren, Hongliang; Xu, Sheng; Wood, Bradford; Tokuda, Junichi; Tse, Zion Tsz Ho

    2017-11-16

    Magnetic resonance imaging (MRI) is beneficial for imaging-guided procedures because it provides higher resolution images and better soft tissue contrast than computed tomography (CT), ultrasound, and X-ray. MRI can be used to streamline diagnostics and treatment because it does not require patients to be repositioned between scans of different areas of the body. It is even possible to use MRI to visualize, power, and control medical devices inside the human body to access remote locations and perform minimally invasive procedures. Therefore, MR conditional medical devices have the potential to improve a wide variety of medical procedures; this potential is explored in terms of practical considerations pertaining to clinical applications and the MRI environment. Recent advancements in this field are introduced with a review of clinically relevant research in the areas of interventional tools, endovascular microbots, and closed-loop controlled MRI robots. Challenges related to technology and clinical feasibility are discussed, including MRI based propulsion and control, navigation of medical devices through the human body, clinical adoptability, and regulatory issues. The development of MRI-powered medical devices is an emerging field, but the potential clinical impact of these devices is promising.

  3. A systematic review of electronic multi-compartment medication devices with reminder systems for improving adherence to self-administered medications.

    Science.gov (United States)

    Paterson, Mary; Kinnear, Moira; Bond, Christine; McKinstry, Brian

    2017-06-01

    Many patients experience difficulties adhering to medication regimes. For people who forget or get confused about medication, there are products to help them such as multi-compartment medication devices (MMDs). Some of these, known as electronic MMDs (eMMDs), use audible and/or visual signals to prompt the patient when to take medication, dispense medications, give instructions to the patient, and contact a caregiver (mobile Internet or text to a carer) as needed. To systematically review the literature on the use of eMMDs, to determine what evidence for their effectiveness is available. A comprehensive literature search of 10 databases, plus an Internet search and hand searching was conducted, using the MeSH terms reminder systems/patient compliance/medication adherence. There were no date restrictions. Inclusion criteria were patients in any community setting, in any country and with no restrictions of age, gender, ethnicity or medical condition, using an eMMD. Peer-reviewed quantitative or qualitative studies of any design were included. Of 805 abstracts identified and 99 full text papers retrieved, six met the inclusion criteria. Five of the studies reported adherence to medication regimes; one reported design factors to improve adherence. Adherence varied by the context of the reminders, the target group and usability of the devices. The studies were small scale and only one was a well conducted randomised controlled trial. Overall methodological quality of the studies was poor. Although positive effects on adherence were reported further, rigorously conducted, studies are needed to inform the use of eMMDs. © 2016 Royal Pharmaceutical Society.

  4. A mixed-method research to investigate the adoption of mobile devices and Web2.0 technologies among medical students and educators.

    Science.gov (United States)

    Fan, Si; Radford, Jan; Fabian, Debbie

    2016-04-19

    The past decade has witnessed the increasing adoption of Web 2.0 technologies in medical education. Recently, the notion of digital habitats, Web 2.0 supported learning environments, has also come onto the scene. While there has been initial research on the use of digital habitats for educational purposes, very limited research has examined the adoption of digital habitats by medical students and educators on mobile devices. This paper reports the Stage 1 findings of a two-staged study. The whole study aimed to develop and implement a personal digital habitat, namely digiMe, for medical students and educators at an Australian university. The first stage, however, examined the types of Web 2.0 tools and mobile devices that are being used by potential digiMe users, and reasons for their adoption. In this first stage of research, data were collected through a questionnaire and semi-structured interviews. Questionnaire data collected from 104 participants were analysed using the Predictive Analytics SoftWare (PASW). Frequencies, median and mean values were pursued. Kruskal Wallis tests were then performed to examine variations between views of different participant groups. Notes from the 6 interviews, together with responses to the open-ended section of the questionnaire, were analysed using the constructivist grounded theory approach, to generate key themes relevant to the adoption of Web 2.0 tools and mobile devices. The findings reflected the wide use of mobile devices, including both smart phones and computing tablets, by medical students and educators for learning, teaching and professional development purposes. Among the 22 types of Web 2.0 tools investigated, less than half of these tools were frequently used by the participants, this reflects the mismatch between users' desires and their actual practice. Age and occupation appeared to be the influential factors for their adoption. Easy access to information and improved communication are main purposes. This

  5. Halo and spillover effect illustrations for selected beneficial medical devices and drugs

    Directory of Open Access Journals (Sweden)

    Brent D. Kerger

    2016-09-01

    Full Text Available Abstract Background Negative news media reports regarding potential health hazards of implanted medical devices and pharmaceuticals can lead to a ‘negative halo effect,’ a phenomenon whereby judgments about a product or product type can be unconsciously altered even though the scientific support is tenuous. To determine how a ‘negative halo effect’ may impact the rates of use and/or explantation of medical products, we analyzed the occurrence of such an effect on three implanted medical devices and one drug: 1 intrauterine contraceptive devices (IUDs; 2 silicone gel-filled breast implants (SGBI; 3 metal-on-metal hip implants (MoM; and 4 the drug Tysabri. Methods Data on IUD use from 1965 to 2008 were gathered from the Department of Health and Human Services Vital and Health Statistics and peer-reviewed publications. Data regarding SGBI implant and explantation rates from 1989 to 2012 were obtained from the Institute of Medicine and the American Society of Plastic Surgeons. MoM implant and explantation data were extracted from the England and Wales National Joint Registry and peer-reviewed publications. Tysabri patient data were reported by Elan Corporation or Biogen Idec Inc. Data trends for all products were compared with historical recall or withdrawal events and discussed in the context of public perceptions following such events. Results We found that common factors altered public risk perceptions and patterns of continued use. First, a negative halo effect may be driven by continuing patient anxiety despite positive clinical outcomes. Second, negative reports about one product can spill over to affect the use of dissimilar products in the same category. Third, a negative halo effect on an entire category of medical devices can be sustained regardless of the scientific findings pertaining to safety. Fourth, recovery of a product’s safety reputation and prevalent use may take decades in the U.S., even while these products may

  6. Risk assessment of medical devices: evaluation of microbiological and toxicological safety

    International Nuclear Information System (INIS)

    Dorpema, J.W.

    1995-01-01

    Safety assessment of medical devices includes sterilization and biological evaluation or biocompatability testing. Sterilization by ETO gas is criticised for their carcinogenic potency or even banned. Mutual acceptance of biological evaluation test results is promoted by a laboratory accreditation and qualification program. (Author)

  7. The Role of Healthcare Technology Management in Facilitating Medical Device Cybersecurity.

    Science.gov (United States)

    Busdicker, Mike; Upendra, Priyanka

    2017-09-02

    This article discusses the role of healthcare technology management (HTM) in medical device cybersecurity and outlines concepts that are applicable to HTM professionals at a healthcare delivery organization or at an integrated delivery network, regardless of size. It provides direction for HTM professionals who are unfamiliar with the security aspects of managing healthcare technologies but are familiar with standards from The Joint Commission (TJC). It provides a useful set of recommendations, including relevant references for incorporating good security practices into HTM practice. Recommendations for policies, procedures, and processes referencing TJC standards are easily applicable to HTM departments with limited resources and to those with no resource concerns. The authors outline processes from their organization as well as best practices learned through information sharing at AAMI, National Health Information Sharing and Analysis Center (NH-ISAC), and Medical Device Innovation, Safety, and Security Consortium (MDISS) conferences and workshops.

  8. Influence of Mobile Phones on the Quality of ECG Signal Acquired by Medical Devices

    Science.gov (United States)

    Buczkowski, T.; Janusek, D.; Zavala-Fernandez, H.; Skrok, M.; Kania, M.; Liebert, A.

    2013-10-01

    Health aspects of the use of radiating devices, like mobile phones, are still a public concern. Stand-alone electrocardiographic systems and those built-in, more sophisticated, medical devices have become a standard tool used in everyday medical practice. GSM mobile phones might be a potential source of electromagnetic interference (EMI) which may affect reliability of medical appliances. Risk of such event is particularly high in places remote from GSM base stations in which the signal received by GSM mobile phone is weak. In such locations an increase in power of transmitted radio signal is necessary to enhance quality of the communication. In consequence, the risk of interference of electronic devices increases because of the high level of EMI. In the present paper the spatial, temporal, and spectral characteristics of the interference have been examined. The influence of GSM mobile phone on multilead ECG recordings was studied. It was observed that the electrocardiographic system was vulnerable to the interference generated by the GSM mobile phone working with maximum transmit power and in DTX mode when the device was placed in a distance shorter than 7.5 cm from the ECG electrode located on the surface of the chest. Negligible EMI was encountered at any longer distance.

  9. Improvised explosive devices: pathophysiology, injury profiles and current medical management.

    Science.gov (United States)

    Ramasamy, A; Hill, A M; Clasper, J C

    2009-12-01

    The improvised explosive device (IED), in all its forms, has become the most significant threat to troops operating in Afghanistan and Iraq. These devices range from rudimentary home made explosives to sophisticated weapon systems containing high-grade explosives. Within this broad definition they may be classified as roadside explosives and blast mines, explosive formed pojectile (EFP) devices and suicide bombings. Each of these groups causeinjury through a number of different mechanisms and can result in vastly different injury profiles. The "Global War on Terror" has meant that incidents which were previously exclusively seen in conflict areas, can occur anywhere, and clinicians who are involved in emergency trauma care may be required to manage casualties from similar terrorist attacks. An understanding of the types of devices and their pathophysiological effects is necessary to allow proper planning of mass casualty events and to allow appropriate management of the complex poly-trauma casualties they invariably cause. The aim of this review article is to firstly describe the physics and injury profile from these different devices and secondly to present the current clinical evidence that underpins their medical management.

  10. Effects of Sterilization Cycles on PEEK for Medical Device Application

    Science.gov (United States)

    Yap, Wai Teng; Foo, Soo Leong; Lee, Teck Kheng

    2018-01-01

    The effects of the sterilization process have been studied on medical grade thermoplastic polyetheretherketone (PEEK). For a reusable medical device, material reliability is an important parameter to decide its lifetime, as it will be subjected to the continuous steam sterilization process. A spring nature, clip component was selected out of a newly designed medical device (patented) to perform this reliability study. This clip component was sterilized for a predetermined number of cycles (2, 4, 6, 8, 10, 20…100) at 121 °C for 30 min. A significant decrease of ~20% in the compression force of the spring was observed after 30 cycles, and a ~6% decrease in the lateral dimension of the clip was observed after 50 cycles. No further significant change in the compression force or dimension was observed for the subsequent sterilization cycles. Vickers hardness and differential scanning calorimetry (DSC) techniques were used to characterize the effects of sterilization. DSC results exhibited no significant change in the degree of cure and melting behavior of PEEK before and after the sterilization. Hardness measurement exhibited an increase of ~49% in hardness after just 20 cycles. When an unsterilized sample was heated for repetitive cycles without the presence of moisture (121 °C, 10 and 20 cycles), only ~7% of the maximum change in hardness was observed. PMID:29466289

  11. Effects of Sterilization Cycles on PEEK for Medical Device Application.

    Science.gov (United States)

    Kumar, Amit; Yap, Wai Teng; Foo, Soo Leong; Lee, Teck Kheng

    2018-02-21

    The effects of the sterilization process have been studied on medical grade thermoplastic polyetheretherketone (PEEK). For a reusable medical device, material reliability is an important parameter to decide its lifetime, as it will be subjected to the continuous steam sterilization process. A spring nature, clip component was selected out of a newly designed medical device (patented) to perform this reliability study. This clip component was sterilized for a predetermined number of cycles (2, 4, 6, 8, 10, 20…100) at 121 °C for 30 min. A significant decrease of ~20% in the compression force of the spring was observed after 30 cycles, and a ~6% decrease in the lateral dimension of the clip was observed after 50 cycles. No further significant change in the compression force or dimension was observed for the subsequent sterilization cycles. Vickers hardness and differential scanning calorimetry (DSC) techniques were used to characterize the effects of sterilization. DSC results exhibited no significant change in the degree of cure and melting behavior of PEEK before and after the sterilization. Hardness measurement exhibited an increase of ~49% in hardness after just 20 cycles. When an unsterilized sample was heated for repetitive cycles without the presence of moisture (121 °C, 10 and 20 cycles), only ~7% of the maximum change in hardness was observed.

  12. Analysis of medical device materials with the local electrode atom probe

    International Nuclear Information System (INIS)

    Goodman, S.L.; Mengelt, T.J.; Ali, M.; Ulfig, R.M.; Martens, R.M.; Kelly, T.F.; Kostrna, S.L.P.; Kostrna, M.S.; Carmichael, W.J.

    2004-01-01

    Full text: As medical technology advances towards microsurgical and minimally invasive techniques, there is a drive to produce ever-smaller devices that demand higher material performance and hence enhanced nano and micro-scale control of material structure. These devices are made from stainless steel alloys, Nitinol, titanium, CoCrMo, and non-metals such as pyrolytic carbon and silicon. These applications are made possible due to suitable physical and mechanical properties, good corrosion resistance in biological environments, reasonable biocompatibility, and good manufacturability. With respect to the metals, the nano-structure and composition of the material surface, typically an oxide, is especially critical since biological responses and corrosion occur at the material-environment interface. Thus, there is an increasing need to understand the 3-D structure and composition of metallic biomaterials at the atomic scale. Three-dimensional atom probe microscopy can uniquely provide such atomic-level structural information. In the present study several of these medical device materials were examined. These include a 316L stainless steel alloy which is widely used in implanted spinal fixation devices, bone screws, cardiovascular and neurological stents, a cast CoCrMo acetabular hip cup of a Cormet metal-on-metal Hip Resurfacing System (Corin Group, Cirencester, England) that was rejected for clinical use, Nitinol wires specimens such as are used for stents and guide wires, and low temperature pyrolytic carbon as used in clinical heart valve prosthetics. (author)

  13. 76 FR 67463 - Pediatric Medical Devices; Public Workshop; Request for Comments

    Science.gov (United States)

    2011-11-01

    ... use, existing scientific research data to determine pediatric effectiveness based on a similar course... research data, and C. The methods to overcome the pitfalls and data gaps, including statistical approaches... announcing a public workshop entitled ``Using Scientific Research Data to Support Pediatric Medical Device...

  14. Approval of devices and facilities using ionizing radiations for medical purposes

    International Nuclear Information System (INIS)

    1977-01-01

    This Order made by the Ministers of Health and Social Security, Agriculture and Labour amends a previous Decree of 23 April 1969 in particular concerning the classification of medical or dental radiodiagnostic devices subject to approval. The technical conditions to be complied with for such devices and facilities have also been amended. Finally, it is provided that, as regards facilities with heavy equipment subject to licensing (Act of 31 December 1970), approval is subject to compliance with the licensing conditions and is requested together with the application for a licence. (NEA) [fr

  15. A balancing act: a phenomenological exploration of medical students' experiences of using mobile devices in the clinical setting.

    Science.gov (United States)

    Rashid-Doubell, F; Mohamed, S; Elmusharaf, K; O'Neill, C S

    2016-05-03

    The aims of this study were to describe the experiences of senior students using mobile devices in a clinical setting while learning and interacting with clinical teachers, patients and each other, and to identify challenges that facilitated or impeded the use of such devices in the hospital. Interpretative phenomenology was chosen to guide our enquiry. Semi-structured interviews were conducted to examine the experiences of five senior medical students using mobile devices in the clinical setting. Senior medical students at an international medical school in the Middle East. Three main themes emerged from the data analysis: learning; professional identity and transitioning from student to doctor. The findings showed that using mobile devices in the clinical area as a learning tool was not a formalised process. Rather, it was opportunistic learning at the bedside and on occasion a source of distraction from clinical teaching. Students needed to negotiate relationships between themselves, the clinical teacher and patients in order to ensure that they maintained an acceptable professional image. Participants experienced and negotiated the change from student to doctor making them mindful of using their devices at the bedside. Mobile devices are part of daily life for a medical student and there is a need to adapt medical education in the clinical setting, to allow the students to use their devices in a sensitive manner. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  16. Potential negative consequences of non-consented switch of inhaled medications and devices in asthma patients.

    Science.gov (United States)

    Björnsdóttir, U S; Gizurarson, S; Sabale, U

    2013-09-01

    Asthma requires individually tailored and careful management to control and prevent symptoms and exacerbations. Selection of the most appropriate treatment is dependent on both the choice of drugs and inhaler device; however, financial pressures may result in patients being switched to alternative medications and devices in an attempt to reduce costs. This review aimed to examine the published literature in order to ascertain whether switching a patient's asthma medications or device negatively impacts clinical and economic outcomes. A literature search of MEDLINE (2001-13 September 2011) was conducted to identify English-language articles focused on the direct impact of switching medications and inhaler devices and switching from fixed-dose combination to monocomponent therapy via separate inhalers in patients with asthma; the indirect impacts of switching were also assessed. Evidence showed that non-consented switching of medications and inhalers in patients with asthma can be associated with a range of negative outcomes, at both individual and organisational levels. Factors that reduce adherence may lead to compromised symptom control resulting in increased healthcare resource utilisation and poorer patient quality of life. The consequences of a non-consented switch should be weighed carefully against arguments supporting an inhaler switch without the patient's consent for non-medical/budgetary reasons, such as potential reductions in initial acquisition costs, which may be associated with subsequent additional healthcare needs. Given the increasing pressure for reduced costs and efficient allocation of limited healthcare resources, an additional investment in ensuring high medication adherence may lead to greater savings due to a potentially decreased demand for healthcare services. In contrast, savings achieved in acquisition costs may result in a greater net loss due to increased healthcare consumption caused by decreased asthma control. © 2013 The Authors

  17. Adherence to hydroxyurea medication by children with sickle cell disease (SCD) using an electronic device: a feasibility study.

    Science.gov (United States)

    Inoue, Susumu; Kodjebacheva, Gergana; Scherrer, Tammy; Rice, Gary; Grigorian, Matthew; Blankenship, Jeremy; Onwuzurike, Nkechi

    2016-08-01

    Adherence to hydroxyurea (HU) is a significant modifying factor in sickle cell vaso-occlusive pain. We conducted a study using an electronic medication container-monitor-reminder device (GlowCap™) to track adherence and determine whether use of this device affected rates of HU adherence. Subjects were regular attendees to our clinic. They were given a 37-item questionnaire and were asked to use a GlowCap containing HU. When the device cap is opened, it makes a remote "medication taken" record. The device also provides usage reminder in the form of lights and alarm sounds if the cap opening is delayed. Nineteen subjects participated in the survey, and 17 in the intervention phase. Of the 17, 12 had reliable adherence data. Seventeen caregivers of patients and two patients completed the survey. Two most common barriers to adherence identified were lack of reminders and absence of medicine home delivery. The intervention component of this study, which used both the electronic (GlowCap) method and medication possession ratio showed that the median adherence rate for the 12 patients evaluated was 85 %. The GlowCap device accurately kept a record of adherence rates. This device may be an effective tool for increasing HU medication adherence.

  18. A study on development of guideline on writing technical document for electrical medical devices: Bone absorptiometric X-ray system

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sung Youl; Kim, Jae Ryang; Kim, Eun Rim; Lee, Jun Ho; Lee, Chang Hyung; Park, Chang Won [Medical Device Research Division, Ministry of Food and Drug Safety, Cheongju (Korea, Republic of)

    2016-06-15

    The market size of the bone absorptiometric X-ray system and the number of its approval by Ministry of Food and Drug Safety (MFDS) has annually increased, with a trend of increasing aging population and osteoporosis patients. For approval of manufactured or imported medical devices in Republic of Korea, it is required to submit its technical document. Therefore, it is need to develop the technical document guideline for the bone absorptiometric X-ray system for manufacturers, importers and reviewers. First of all, the technical documents which were already approved were examined and analyzed through MFDS approval administration system. Second, safety and performance test standards and methods that match international standards were drawn after conducting survey of the market status and the technology development trend for it, with examination and analysis of applicable domestic and overseas standards. Third, by operating industry-research-government cooperation, the guideline draft on writing technical document for the bone absorptiometric X-ray system was discussed, collecting their opinion. As a result, it is suitable to international and domestic condition, includes test evaluation methods and offer various information with appropriate examples to civil petitioner, when they write the technical documents.

  19. A study on development of guideline on writing technical document for electrical medical devices: Bone absorptiometric X-ray system

    International Nuclear Information System (INIS)

    Lee, Sung Youl; Kim, Jae Ryang; Kim, Eun Rim; Lee, Jun Ho; Lee, Chang Hyung; Park, Chang Won

    2016-01-01

    The market size of the bone absorptiometric X-ray system and the number of its approval by Ministry of Food and Drug Safety (MFDS) has annually increased, with a trend of increasing aging population and osteoporosis patients. For approval of manufactured or imported medical devices in Republic of Korea, it is required to submit its technical document. Therefore, it is need to develop the technical document guideline for the bone absorptiometric X-ray system for manufacturers, importers and reviewers. First of all, the technical documents which were already approved were examined and analyzed through MFDS approval administration system. Second, safety and performance test standards and methods that match international standards were drawn after conducting survey of the market status and the technology development trend for it, with examination and analysis of applicable domestic and overseas standards. Third, by operating industry-research-government cooperation, the guideline draft on writing technical document for the bone absorptiometric X-ray system was discussed, collecting their opinion. As a result, it is suitable to international and domestic condition, includes test evaluation methods and offer various information with appropriate examples to civil petitioner, when they write the technical documents

  20. A workshop on developing risk assessment methods for medical use of radioactive material. Volume 2: Supporting documents

    Energy Technology Data Exchange (ETDEWEB)

    Tortorelli, J.P. [ed.] [Lockheed Idaho Technologies Co., Idaho Falls, ID (United States)

    1995-08-01

    A workshop was held at the Idaho National Engineering Laboratory, August 16--18, 1994 on the topic of risk assessment on medical devices that use radioactive isotopes. Its purpose was to review past efforts to develop a risk assessment methodology to evaluate these devices, and to develop a program plan and a scoping document for future methodology development. This report contains presentation material and a transcript of the workshop. Participants included experts in the fields of radiation oncology, medical physics, risk assessment, human-error analysis, and human factors. Staff from the US Nuclear Regulatory Commission (NRC) associated with the regulation of medical uses of radioactive materials and with research into risk-assessment methods participated in the workshop. The workshop participants concurred in NRC`s intended use of risk assessment as an important technology in the development of regulations for the medical use of radioactive material and encouraged the NRC to proceed rapidly with a pilot study. Specific recommendations are included in the executive summary and the body of this report.

  1. A workshop on developing risk assessment methods for medical use of radioactive material. Volume 2: Supporting documents

    International Nuclear Information System (INIS)

    Tortorelli, J.P.

    1995-08-01

    A workshop was held at the Idaho National Engineering Laboratory, August 16--18, 1994 on the topic of risk assessment on medical devices that use radioactive isotopes. Its purpose was to review past efforts to develop a risk assessment methodology to evaluate these devices, and to develop a program plan and a scoping document for future methodology development. This report contains presentation material and a transcript of the workshop. Participants included experts in the fields of radiation oncology, medical physics, risk assessment, human-error analysis, and human factors. Staff from the US Nuclear Regulatory Commission (NRC) associated with the regulation of medical uses of radioactive materials and with research into risk-assessment methods participated in the workshop. The workshop participants concurred in NRC's intended use of risk assessment as an important technology in the development of regulations for the medical use of radioactive material and encouraged the NRC to proceed rapidly with a pilot study. Specific recommendations are included in the executive summary and the body of this report

  2. The effects of cosmic radiation on implantable medical devices

    International Nuclear Information System (INIS)

    Bradley, P.

    1996-01-01

    Metal oxide semiconductor (MOS) integrated circuits, with the benefits of low power consumption, represent the state of the art technology for implantable medical devices. Three significant sources of radiation are classified as having the ability to damage or alter the behavior of implantable electronics; Secondary neutron cosmic radiation, alpha particle radiation from the device packaging and therapeutic doses(up to 70 Gγ) of high energy radiation used in radiation oncology. The effects of alpha particle radiation from the packaging may be eliminated by the use of polyimide or silicone rubber die coatings. The relatively low incidence of therapeutic radiation incident on an implantable device and the use of die coating leaves cosmic radiation induced secondary neutron single event upset (SEU) as the main pervasive ionising radiation threat to the reliability of implantable devices. A theoretical model which predicts the susceptibility of a RAM cell to secondary neutron cosmic radiation induced SEU is presented. The model correlates well within the statistical uncertainty associated with both the theoretical and field estimate. The predicted Soft Error Rate (SER) is 4.8 x l0 -12 upsets/(bit hr) compared to an observed upset rate of 8.5 x 10 -12 upsets/(bit hr) from 20 upsets collected over a total of 284672 device days. The predicted upset rate may increase by up to 20% when consideration is given to patients flying in aircraft The upset rate is also consistent with the expected geographical variations of the secondary cosmic ray neutron flux, although insufficient upsets precluded a statistically significant test. This is the first clinical data set obtained indicating the effects of cosmic radiation on implantable devices. Importantly, it may be used to predict the susceptibility of future to the implantable device designs to the effects of cosmic radiation

  3. ISO 13485: a complete guide to quality management in the medical device industry

    National Research Council Canada - National Science Library

    Abuhav, Itay

    2012-01-01

    .... Written by an experienced industry professional, this practical book provides a complete guide to the ISO 13485 standard certification for medical device manufacturing in terms of quality control...

  4. Proposed changes to the reimbursement of pharmaceuticals and medical devices in Poland and their impact on market access and the pharmaceutical industry

    Science.gov (United States)

    Badora, Karolina; Caban, Aleksandra; Rémuzat, Cécile; Dussart, Claude; Toumi, Mondher

    2017-01-01

    ABSTRACT In Poland, two proposed amendments to the reimbursement act are currently in preparation; these are likely to substantially change the pricing and reimbursement landscape for both drugs and medical devices. Proposed changes include: alignment of medical device reimbursement with that of pharmaceuticals; relaxing the strict reimbursement criteria for ultra-orphan drugs; establishment of an additional funding category for vaccines; introduction of compassionate use, and a simplified reimbursement pathway for well-established off-label indications; appreciation of manufacturers’ innovation and research and development efforts by creating a dedicated innovation budget; introduction of a mechanism preventing excessive parallel import; prolonged duration of reimbursement decisions and reimbursement lists; and increased flexibility in defining drug programmes. Both amendments are still at a draft stage and many aspects of the new regulations remain unclear. Nonetheless, the overall direction of some of the changes is already evident and warrants discussion due to their high expected impact on pharmaceutical and device manufacturers. Here we evaluate the main changes proposed to the reimbursement of drugs, vaccines, and medical devices, and examine the impact they are likely to have on market access and pharmaceutical industry in Poland. PMID:29081924

  5. Outsourcing versus in-house maintenance of medical devices: a longitudinal, empirical study.

    Science.gov (United States)

    Miguel-Cruz, Antonio; Rios-Rincón, Adriana; Haugan, Gregory L

    2014-03-01

    To determine what factors have a significant influence on the performance of medical device maintenance outsourcing, and to determine how the performance of external governance structures differs depending on whether a hospital is private or public. This was a longitudinal study of 590 maintenance transactions at 20 hospitals in Bogotá, Colombia, involving 764 medical devices and 72 maintenance service providers. Maintenance performance data (i.e., turn-around time in hours; TAT) for the service providers (either in-house or outsourced) were primarily collected over a 20-month period, from December 2009-August 2011, by means of a monitoring procedure; then, a hazards model was run. The availability of specific repair parts, in-stock, in the city in which the medical devices were located, had a positive impact on the performance of both internal and external governance structures. Online service also had a positive impact on both, with a stronger positive impact on the performance of internal governance than on that of external governance. For transactions governed by external structures, better performance was seen in private hospitals than in public ones. In public health institutions, internal governance showed better performance than external governance. Both internal and external governance structures showed better performance in private healthcare institutions than in public ones. In public health institutions, internal governance shows better performance than external governance; this suggests that healthcare managers should reconsider the trend to eliminate in-house maintenance service staff in public healthcare institutions.

  6. A flexible super-capacitive solid-state power supply for miniature implantable medical devices.

    Science.gov (United States)

    Meng, Chuizhou; Gall, Oren Z; Irazoqui, Pedro P

    2013-12-01

    We present a high-energy local power supply based on a flexible and solid-state supercapacitor for miniature wireless implantable medical devices. Wireless radio-frequency (RF) powering recharges the supercapacitor through an antenna with an RF rectifier. A power management circuit for the super-capacitive system includes a boost converter to increase the breakdown voltage required for powering device circuits, and a parallel conventional capacitor as an intermediate power source to deliver current spikes during high current transients (e.g., wireless data transmission). The supercapacitor has an extremely high area capacitance of ~1.3 mF/mm(2), and is in the novel form of a 100 μm-thick thin film with the merit of mechanical flexibility and a tailorable size down to 1 mm(2) to meet various clinical dimension requirements. We experimentally demonstrate that after fully recharging the capacitor with an external RF powering source, the supercapacitor-based local power supply runs a full system for electromyogram (EMG) recording that consumes ~670 μW with wireless-data-transmission functionality for a period of ~1 s in the absence of additional RF powering. Since the quality of wireless powering for implantable devices is sensitive to the position of those devices within the RF electromagnetic field, this high-energy local power supply plays a crucial role in providing continuous and reliable power for medical device operations.

  7. 47 CFR 95.1121 - Specific requirements for wireless medical telemetry devices operating in the 1395-1400 and 1427...

    Science.gov (United States)

    2010-10-01

    ... wireless medical telemetry devices operating in the 1395-1400 and 1427-1432 MHz bands. Due to the critical... 47 Telecommunication 5 2010-10-01 2010-10-01 false Specific requirements for wireless medical telemetry devices operating in the 1395-1400 and 1427-1432 MHz bands. 95.1121 Section 95.1121...

  8. In situ formation of antimicrobial silver nanoparticles and the impregnation of hydrophobic polycaprolactone matrix for antimicrobial medical device applications.

    Science.gov (United States)

    Tran, Phong A; Hocking, Dianna M; O'Connor, Andrea J

    2015-02-01

    Bacterial infection associated with medical devices remains a challenge to modern medicine as more patients are being implanted with medical devices that provide surfaces and environment for bacteria colonization. In particular, bacteria are commonly found to adhere more preferably to hydrophobic materials and many of which are used to make medical devices. Bacteria are also becoming increasingly resistant to common antibiotic treatments as a result of misuse and abuse of antibiotics. There is an urgent need to find alternatives to antibiotics in the prevention and treatment of device-associated infections world-wide. Silver nanoparticles have emerged as a promising non-drug antimicrobial agent which has shown effectiveness against a wide range of both Gram-negative and Gram-positive pathogen. However, for silver nanoparticles to be clinically useful, they must be properly incorporated into medical device materials whose wetting properties could be detrimental to not only the incorporation of the hydrophilic Ag nanoparticles but also the release of active Ag ions. This study aimed at impregnating the hydrophobic polycaprolactone (PCL) polymer, which is a FDA-approved polymeric medical device material, with hydrophilic silver nanoparticles. Furthermore, a novel approach was employed to uniformly, incorporate silver nanoparticles into the PCL matrix in situ and to improve the release of Ag ions from the matrix so as to enhance antimicrobial efficacy. Copyright © 2014. Published by Elsevier B.V.

  9. 77 FR 26769 - Educational Forum on Medical Device Reporting, Complaint Files, and Recalls, Corrections, and...

    Science.gov (United States)

    2012-05-07

    ... Device Quality Systems Regulation (QSR) to the regulated industry, particularly small businesses. DATES... registration fee will be used to offset expenses of hosting the event including continental breakfast, lunch... interest in the topics discussed from small medical device manufacturers in the Dallas District area. This...

  10. Use of endpoint adjudication to improve the quality and validity of endpoint assessment for medical device development and post marketing evaluation: Rationale and best practices. A report from the cardiac safety research consortium.

    Science.gov (United States)

    Seltzer, Jonathan H; Heise, Ted; Carson, Peter; Canos, Daniel; Hiatt, Jo Carol; Vranckx, Pascal; Christen, Thomas; Cutlip, Donald E

    2017-08-01

    This white paper provides a summary of presentations, discussions and conclusions of a Thinktank entitled "The Role of Endpoint Adjudication in Medical Device Clinical Trials". The think tank was cosponsored by the Cardiac Safety Research Committee, MDEpiNet and the US Food and Drug Administration (FDA) and was convened at the FDA's White Oak headquarters on March 11, 2016. Attention was focused on tailoring best practices for evaluation of endpoints in medical device clinical trials, practical issues in endpoint adjudication of therapeutic, diagnostic, biomarker and drug-device combinations, and the role of adjudication in regulatory and reimbursement issues throughout the device lifecycle. Attendees included representatives from medical device companies, the FDA, Centers for Medicare and Medicaid Services (CMS), end point adjudication specialist groups, clinical research organizations, and active, academically based adjudicators. The manuscript presents recommendations from the think tank regarding (1) rationale for when adjudication is appropriate, (2) best practices establishment and operation of a medical device adjudication committee and (3) the role of endpoint adjudication for post market evaluation in the emerging era of real world evidence. Copyright © 2017. Published by Elsevier Inc.

  11. Development of a wireless blood pressure measuring device with smart mobile device.

    Science.gov (United States)

    İlhan, İlhan; Yıldız, İbrahim; Kayrak, Mehmet

    2016-03-01

    Today, smart mobile devices (telephones and tablets) are very commonly used due to their powerful hardware and useful features. According to an eMarketer report, in 2014 there were 1.76 billion smartphone users (excluding users of tablets) in the world; it is predicted that this number will rise by 15.9% to 2.04 billion in 2015. It is thought that these devices can be used successfully in biomedical applications. A wireless blood pressure measuring device used together with a smart mobile device was developed in this study. By means of an interface developed for smart mobile devices with Android and iOS operating systems, a smart mobile device was used both as an indicator and as a control device. The cuff communicating with this device through Bluetooth was designed to measure blood pressure via the arm. A digital filter was used on the cuff instead of the traditional analog signal processing and filtering circuit. The newly developed blood pressure measuring device was tested on 18 patients and 20 healthy individuals of different ages under a physician's supervision. When the test results were compared with the measurements made using a sphygmomanometer, it was shown that an average 93.52% accuracy in sick individuals and 94.53% accuracy in healthy individuals could be achieved with the new device. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  12. 78 FR 950 - Medical Devices; Availability of Safety and Effectiveness Summaries for Premarket Approval...

    Science.gov (United States)

    2013-01-07

    ..., FDA- 2012-M-0965, FDA-2012-M-0968, FDA-2012-M-1011, and FDA-2012-M-1013] Medical Devices; Availability.... Glucose Monitoring System (TGMS). P000008/S017, FDA-2012-M-1013.. Allergan, Inc..... LAP-BAND \\TM\\ February 16, 2011. Adjustable Gastric Banding System. P100049, FDA-2012-M-0893....... Torax Medical, Inc...

  13. Security and Privacy Qualities of Medical Devices: An Analysis of FDA Postmarket Surveillance

    OpenAIRE

    Ransford, Benjamin; Molina-Markham, Andres; Stewart, Quinn; Fu, Kevin; Kramer, Daniel Bruce; Baker, Matthew Charles; Reynolds, Matthew R.

    2012-01-01

    Background: Medical devices increasingly depend on computing functions such as wireless communication and Internet connectivity for software-based control of therapies and network-based transmission of patients’ stored medical information. These computing capabilities introduce security and privacy risks, yet little is known about the prevalence of such risks within the clinical setting. Methods: We used three comprehensive, publicly available databases maintained by the Food and Drug Admini...

  14. Taking transition into account: designing with pre-users of medical devices

    DEFF Research Database (Denmark)

    Kelly, Janet; Matthews, Ben

    2010-01-01

    of the product. We present a case study that documents how we worked with pre-users of two different types of medical technologies: hearing aids and insulin injection devices. Pre-users are people who do not currently use these products, but who are in a life situation for which these technologies may...

  15. Corruption in the health care sector: A barrier to access of orthopaedic care and medical devices in Uganda.

    Science.gov (United States)

    Bouchard, Maryse; Kohler, Jillian C; Orbinski, James; Howard, Andrew

    2012-05-03

    Globally, injuries cause approximately as many deaths per year as HIV/AIDS, tuberculosis and malaria combined, and 90% of injury deaths occur in low- and middle- income countries. Given not all injuries kill, the disability burden, particularly from orthopaedic injuries, is much higher but is poorly measured at present. The orthopaedic services and orthopaedic medical devices needed to manage the injury burden are frequently unavailable in these countries. Corruption is known to be a major barrier to access of health care, but its effects on access to orthopaedic services is still unknown. A qualitative case study of 45 open-ended interviews was conducted to investigate the access to orthopaedic health services and orthopaedic medical devices in Uganda. Participants included orthopaedic surgeons, related healthcare professionals, industry and government representatives, and patients. Participants' experiences in accessing orthopaedic medical devices were explored. Thematic analysis was used to analyze and code the transcripts. Analysis of the interview data identified poor leadership in government and corruption as major barriers to access of orthopaedic care and orthopaedic medical devices. Corruption was perceived to occur at the worker, hospital and government levels in the forms of misappropriation of funds, theft of equipment, resale of drugs and medical devices, fraud and absenteeism. Other barriers elicited included insufficient health infrastructure and human resources, and high costs of orthopaedic equipment and poverty. This study identified perceived corruption as a significant barrier to access of orthopaedic care and orthopaedic medical devices in Uganda. As the burden of injury continues to grow, the need to combat corruption and ensure access to orthopaedic services is imperative. Anti-corruption strategies such as transparency and accountability measures, codes of conduct, whistleblower protection, and higher wages and benefits for workers could be

  16. Corruption in the health care sector: A barrier to access of orthopaedic care and medical devices in Uganda

    Directory of Open Access Journals (Sweden)

    Bouchard Maryse

    2012-05-01

    Full Text Available Abstract Background Globally, injuries cause approximately as many deaths per year as HIV/AIDS, tuberculosis and malaria combined, and 90% of injury deaths occur in low- and middle- income countries. Given not all injuries kill, the disability burden, particularly from orthopaedic injuries, is much higher but is poorly measured at present. The orthopaedic services and orthopaedic medical devices needed to manage the injury burden are frequently unavailable in these countries. Corruption is known to be a major barrier to access of health care, but its effects on access to orthopaedic services is still unknown. Methods A qualitative case study of 45 open-ended interviews was conducted to investigate the access to orthopaedic health services and orthopaedic medical devices in Uganda. Participants included orthopaedic surgeons, related healthcare professionals, industry and government representatives, and patients. Participants’ experiences in accessing orthopaedic medical devices were explored. Thematic analysis was used to analyze and code the transcripts. Results Analysis of the interview data identified poor leadership in government and corruption as major barriers to access of orthopaedic care and orthopaedic medical devices. Corruption was perceived to occur at the worker, hospital and government levels in the forms of misappropriation of funds, theft of equipment, resale of drugs and medical devices, fraud and absenteeism. Other barriers elicited included insufficient health infrastructure and human resources, and high costs of orthopaedic equipment and poverty. Conclusions This study identified perceived corruption as a significant barrier to access of orthopaedic care and orthopaedic medical devices in Uganda. As the burden of injury continues to grow, the need to combat corruption and ensure access to orthopaedic services is imperative. Anti-corruption strategies such as transparency and accountability measures, codes of conduct

  17. Corruption in the health care sector: A barrier to access of orthopaedic care and medical devices in Uganda

    Science.gov (United States)

    2012-01-01

    Background Globally, injuries cause approximately as many deaths per year as HIV/AIDS, tuberculosis and malaria combined, and 90% of injury deaths occur in low- and middle- income countries. Given not all injuries kill, the disability burden, particularly from orthopaedic injuries, is much higher but is poorly measured at present. The orthopaedic services and orthopaedic medical devices needed to manage the injury burden are frequently unavailable in these countries. Corruption is known to be a major barrier to access of health care, but its effects on access to orthopaedic services is still unknown. Methods A qualitative case study of 45 open-ended interviews was conducted to investigate the access to orthopaedic health services and orthopaedic medical devices in Uganda. Participants included orthopaedic surgeons, related healthcare professionals, industry and government representatives, and patients. Participants’ experiences in accessing orthopaedic medical devices were explored. Thematic analysis was used to analyze and code the transcripts. Results Analysis of the interview data identified poor leadership in government and corruption as major barriers to access of orthopaedic care and orthopaedic medical devices. Corruption was perceived to occur at the worker, hospital and government levels in the forms of misappropriation of funds, theft of equipment, resale of drugs and medical devices, fraud and absenteeism. Other barriers elicited included insufficient health infrastructure and human resources, and high costs of orthopaedic equipment and poverty. Conclusions This study identified perceived corruption as a significant barrier to access of orthopaedic care and orthopaedic medical devices in Uganda. As the burden of injury continues to grow, the need to combat corruption and ensure access to orthopaedic services is imperative. Anti-corruption strategies such as transparency and accountability measures, codes of conduct, whistleblower protection, and higher

  18. Design for Additive Bio-Manufacturing: From Patient-Specific Medical Devices to Rationally Designed Meta-Biomaterials.

    Science.gov (United States)

    Zadpoor, Amir A

    2017-07-25

    Recent advances in additive manufacturing (AM) techniques in terms of accuracy, reliability, the range of processable materials, and commercial availability have made them promising candidates for production of functional parts including those used in the biomedical industry. The complexity-for-free feature offered by AM means that very complex designs become feasible to manufacture, while batch-size-indifference enables fabrication of fully patient-specific medical devices. Design for AM (DfAM) approaches aim to fully utilize those features for development of medical devices with substantially enhanced performance and biomaterials with unprecedented combinations of favorable properties that originate from complex geometrical designs at the micro-scale. This paper reviews the most important approaches in DfAM particularly those applicable to additive bio-manufacturing including image-based design pipelines, parametric and non-parametric designs, metamaterials, rational and computationally enabled design, topology optimization, and bio-inspired design. Areas with limited research have been identified and suggestions have been made for future research. The paper concludes with a brief discussion on the practical aspects of DfAM and the potential of combining AM with subtractive and formative manufacturing processes in so-called hybrid manufacturing processes.

  19. Design for Additive Bio-Manufacturing: From Patient-Specific Medical Devices to Rationally Designed Meta-Biomaterials

    Directory of Open Access Journals (Sweden)

    Amir A. Zadpoor

    2017-07-01

    Full Text Available Recent advances in additive manufacturing (AM techniques in terms of accuracy, reliability, the range of processable materials, and commercial availability have made them promising candidates for production of functional parts including those used in the biomedical industry. The complexity-for-free feature offered by AM means that very complex designs become feasible to manufacture, while batch-size-indifference enables fabrication of fully patient-specific medical devices. Design for AM (DfAM approaches aim to fully utilize those features for development of medical devices with substantially enhanced performance and biomaterials with unprecedented combinations of favorable properties that originate from complex geometrical designs at the micro-scale. This paper reviews the most important approaches in DfAM particularly those applicable to additive bio-manufacturing including image-based design pipelines, parametric and non-parametric designs, metamaterials, rational and computationally enabled design, topology optimization, and bio-inspired design. Areas with limited research have been identified and suggestions have been made for future research. The paper concludes with a brief discussion on the practical aspects of DfAM and the potential of combining AM with subtractive and formative manufacturing processes in so-called hybrid manufacturing processes.

  20. Concordance of Adherence Measurement Using Self-Reported Adherence Questionnaires and Medication Monitoring Devices: An Updated Review.

    Science.gov (United States)

    Monnette, Alisha; Zhang, Yichen; Shao, Hui; Shi, Lizheng

    2018-01-01

    As medication adherence continues to be a prevalent issue in today's society, the methods used to monitor medication-taking behaviors are constantly being re-evaluated and compared in search of the 'gold standard' measure. Our review aimed to assess the current literature surrounding the correlation between self-reported questionnaires (SRQs) and electronic monitoring devices to determine if these measures produce similar results. We performed a literature search from 2009 to 2017 using PubMed, PubMed In-Process and Non-Indexed, EMBASE, Ovid MEDLINE, and Ovid MEDLINE In-Process. A keyword search using the terms 'patient compliance', 'treatment compliance', 'medication adherence', 'drug monitoring', 'drug therapy', 'electronic', 'digital', 'computer', 'monitor', 'monitoring', 'drug', 'pharmaceutical preparations', 'compliance', and 'medications' was done to capture all articles. We included articles measuring adherence using both monitoring devices and SRQs. Thirty-five articles were included in this review. The average difference in measured adherence rates between the two measures was 9.2% (range -66.3 to 61.5). A majority (62.7%) of articles reported moderate (n = 12; 27.9%), high (n = 5, 11.6%), or significant (n = 10, 23.3%) correlations between SRQs and monitoring devices. Results from our review are consistent with previous studies, as we found that many of our studies produced moderate to high correlation between both SRQs and monitoring devices [Farmer, Clin Ther 21(6):1074-90 (1999), IMS Institute for Healthcare Informatics. Avoidable costs in US health care (2012), Patel et al., Respirology 18(3):546-52 (2013), Siracusa et al., J Cyst Fibros 14(5):621-6 (2015), Smith et al., Int J Cardiol 145(1):122-3 (2010)]. Our findings demonstrate that self-reported adherence produces comparable results to electronic monitoring devices. As there is not yet a 'gold standard' measure for monitoring patient adherence, SRQs and Medication Event Monitoring Systems

  1. Combining multi-criteria decision analysis and mini-health technology assessment: A funding decision-support tool for medical devices in a university hospital setting.

    Science.gov (United States)

    Martelli, Nicolas; Hansen, Paul; van den Brink, Hélène; Boudard, Aurélie; Cordonnier, Anne-Laure; Devaux, Capucine; Pineau, Judith; Prognon, Patrice; Borget, Isabelle

    2016-02-01

    At the hospital level, decisions about purchasing new and oftentimes expensive medical devices must take into account multiple criteria simultaneously. Multi-criteria decision analysis (MCDA) is increasingly used for health technology assessment (HTA). One of the most successful hospital-based HTA approaches is mini-HTA, of which a notable example is the Matrix4value model. To develop a funding decision-support tool combining MCDA and mini-HTA, based on Matrix4value, suitable for medical devices for individual patient use in French university hospitals - known as the IDA tool, short for 'innovative device assessment'. Criteria for assessing medical devices were identified from a literature review and a survey of 18 French university hospitals. Weights for the criteria, representing their relative importance, were derived from a survey of 25 members of a medical devices committee using an elicitation technique involving pairwise comparisons. As a test of its usefulness, the IDA tool was applied to two new drug-eluting beads (DEBs) for transcatheter arterial chemoembolization. The IDA tool comprises five criteria and weights for each of two over-arching categories: risk and value. The tool revealed that the two new DEBs conferred no additional value relative to DEBs currently available. Feedback from participating decision-makers about the IDA tool was very positive. The tool could help to promote a more structured and transparent approach to HTA decision-making in French university hospitals. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. What do you mean you can't sterilize it? The reusable medical device matrix.

    Science.gov (United States)

    Stephens, Anne; Assang, AnnMarie

    2010-12-01

    Health Canada recommends that hospitals should have procedures in place to ensure Reusable Medical Devices (RMD) are cleaned, disinfected and sterilized according to the manufacturer's instructions. For the purpose of this paper, reusable medical devices will be referred to as RMDs and include all instrumentation and devices that the Central Processing Department (CPD) resterilizes for use in the hospital. Patient safety in surgery begins in CPD. Manufacturer recommendations for the decontamination and sterilization of surgical instrumentation are of utmost importance to Operating Room (OR) and CPD staff. With recommendations that are unclear, nonspecific or unattainable there was a need to define what it means institutionally to meet standards and provide safe patient care while continuing to support the advancement of surgical technology. The purpose of this paper is to describe the challenges faced by one multisite organization (The University Health Network) in managing the sterilization of surgical instrumentation. The development of The Guidance Matrix by the network's inter-professional Reusable Medical Device (RMD) Committee, will be discussed along with information about the elements of this tool and an illustration of how it is used. The key benefits of The Guidance Matrix, including how its use has facilitated transparent decision-making, communication and collaboration regarding sterilization issues across the sites, will be described. Sterilization processes in Central Processing Departments (CPD) include chemical indicators, dated load indicators, and tamperproof locks and filters. The lack of an indicator of sterilization can be a frustrating experience for an OR Nurse. But do we really understand the critical importance of all these indicators? The foundation of sterilizing reusable medical devices (RMDs) begins with proper processes, standards and subsequent scientific validation from the vendors. According to AORN, patient safety is vital and it

  3. Antimicrobial treatment of polymeric medical devices by silver nanomaterials and related technology

    Czech Academy of Sciences Publication Activity Database

    Polívková, A.; Hubáček, Tomáš; Staszek, M.; Švorčík, V.; Siegel, J.

    2017-01-01

    Roč. 18, č. 2 (2017), č. článku 419. E-ISSN 1422-0067 Institutional support: RVO:60077344 Keywords : antimicrobials * medical devices * nanostructures * polymers * modification Subject RIV: JJ - Other Materials OBOR OECD: Materials engineering Impact factor: 3.226, year: 2016

  4. PRE-MARKET CLINICAL EVALUATIONS OF INNOVATIVE HIGH-RISK MEDICAL DEVICES IN EUROPE

    DEFF Research Database (Denmark)

    Hulstaert, F.; Neyt, M.; Vinck, I.

    2012-01-01

    data are available? We studied the premarket clinical evaluation of innovative high-risk medical devices in Europe compared with the US, and with medicines, where appropriate. Methods: The literature and regulatory documents were checked. Representatives from industry, Competent Authorities, Notified...... of premarket trials in Europe and number of patients exposed, but failed as this information is not made public. Furthermore, the Helsinki Declaration is not followed with respect to the registration and publication of premarket trials. Conclusions: For innovative high-risk devices, new EU legislation should...

  5. Development of Skylab medical equipment and flight preparations

    Science.gov (United States)

    Johnston, R. S.; Stonesifer, J. C.; Hawkins, W. R.

    1975-01-01

    The major medical systems in the Skylab orbital workshop are described. They comprise the food system, the waste management system, operational bioinstrumentation, personal hygiene, gas sampling, an inflight medical support system, and a cardiovascular counterpressure garment. Life sciences experiments carried out aboard Skylab are also reviewed; these include an ergometer and metabolic analyzer, a lower-body negative pressure device, an electrode harness and body temperature probe, a blood pressure cuff, a leg volume measuring band, sleep studies, a body-mass measuring device, a rotating litter chair, a blood sample processor, and small-mass measuring apparatus. All performance requirements were met with the equipment, and no failures were encountered.

  6. Risiken und Nebenwirkungen der Integration medizinischer Software in klinische IT-Strukturen – Erlanger Memorandum [Software as a medical device – side effects when applying the new European regulation on medical devices for IT products

    Directory of Open Access Journals (Sweden)

    Kaiser, J.

    2012-12-01

    Full Text Available [english] European medical device regulations have been altered to cover pure software applications as well. They now may be classified as a medical device if used for medical diagnostics and/or medical treatment. Slowly, these regulations are being implemented into national law of the EEC member states, for example into the German MPG (Medical Product Law.For some software applications such as Picture Archiving and Communication systems (PACS a classification as medical device is – at least for parts of it – routine today, ruling e.g. the quality of medical monitor screens for assessment of x-ray pictures. For software applications such as patient data management systems (PDMS, electronic health records (EHR, laboratory information systems and similar systems this was not the case so far. This paper deals with the consequences which may arise if a PDMS used on intensive care units or even an EHR is now classified as a medical device, e.g. because it is able to deliver intelligent composite views on laboratory data, medical data, and treatment information to support diagnostic assessment or treatment advice.Modern clinical information systems, PDMS and EHR support the user with medical information and clinical decision support (CDSS. So there is doubt that they are used for diagnostics and/or treatment. Medical device regulations distinguish between medical product classes I (low risk, II and III (high risk of medical devices according to potential risks for the patient. IF CDSS functions e.g. as modules of a PDMS use vital sign values in the decision algorithms, the PDMS may even be classified as class II medical product, similar to e.g. intravenous pumps. If decision rules of a decision support-system are defined by IT-administrators working for a hospital itself it could even become manufacturer of the medical device.The authors discuss implications and demonstrate difficulties which arise for manufacturers as well as for hospitals or the

  7. The Challenges of Balancing Safety and Security in Implantable Medical Devices.

    Science.gov (United States)

    Katzis, Konstantinos; Jones, Richard W; Despotou, George

    2016-01-01

    Modern Implantable Medical Devices (IMDs), implement capabilities that have contributed significantly to patient outcomes, as well as quality of life. The ever increasing connectivity of IMD's does raise security concerns though there are instances where implemented security measures might impact on patient safety. The paper discusses challenges of addressing both of these attributes in parallel.

  8. Outsourcing versus in-house maintenance of medical devices: a longitudinal, empirical study

    Directory of Open Access Journals (Sweden)

    Antonio Miguel-Cruz

    2014-03-01

    Full Text Available OBJECTIVE: To determine what factors have a significant influence on the performance of medical device maintenance outsourcing, and to determine how the performance of external governance structures differs depending on whether a hospital is private or public. METHODS: This was a longitudinal study of 590 maintenance transactions at 20 hospitals in Bogotá, Colombia, involving 764 medical devices and 72 maintenance service providers. Maintenance performance data (i.e., turn-around time in hours; TAT for the service providers (either in-house or outsourced were primarily collected over a 20-month period, from December 2009-August 2011, by means of a monitoring procedure; then, a hazards model was run. RESULTS: The availability of specific repair parts, in-stock, in the city in which the medical devices were located, had a positive impact on the performance of both internal and external governance structures. Online service also had a positive impact on both, with a stronger positive impact on the performance of internal governance than on that of external governance. For transactions governed by external structures, better performance was seen in private hospitals than in public ones. In public health institutions, internal governance showed better performance than external governance. Both internal and external governance structures showed better performance in private healthcare institutions than in public ones. CONCLUSIONS: In public health institutions, internal governance shows better performance than external governance; this suggests that healthcare managers should reconsider the trend to eliminate in-house maintenance service staff in public healthcare institutions.

  9. [The SWOT analysis and strategic considerations for the present medical devices' procurement].

    Science.gov (United States)

    Li, Bin; He, Meng-qiao; Cao, Jian-wen

    2006-05-01

    In this paper, the SWOT analysis method is used to find out the internal strength, weakness, exterior opportunities and threats of the present medical devices' procurements in hospitals and some strategic considerations are suggested as "one direction, two expansions, three changes and four countermeasures".

  10. Extraterritorial reach of the FCPA: recommendations for U.S. medical device companies with activities in Europe.

    Science.gov (United States)

    Vollebregt, Erik

    2010-01-01

    Traditionally medical devices companies manage business compliance with anti-corruption and anti-fraud rules in a document-oriented way that does not always yield optimal results for the company. As a result, compliance issues are not optimally managed by the companies. Now that medical devices companies become ever more internationally active, they must also take into account the international dimensions of business compliance. This article intends to provide U.S. medical devices companies with activities in Europe with an insight in business compliance risks in the European Union (EU) and the risks related to U.S. statutes that may be applicable to a U.S. company's activities overseas. The article proposes a process-oriented and IT-supported way of structuring an international business compliance program, resulting in increased effectiveness of the program and increased competitiveness and risk management of the company as well as a high degree of acceptance of the procedures by the company's employees.

  11. 78 FR 951 - Accessible Medical Device Labeling in a Standard Content and Format Public Workshop; Request for...

    Science.gov (United States)

    2013-01-07

    ... format so that patients, caregivers, and healthcare providers may access and utilize device labeling as... labeling, and what they would want in a standard version of device labeling. Key findings from the survey... survey with the National Family Caregivers Association (NFCA) on medical device labeling to elicit home...

  12. Medical Device Regulation: A Comparison of the United States and the European Union.

    Science.gov (United States)

    Maak, Travis G; Wylie, James D

    2016-08-01

    Medical device regulation is a controversial topic in both the United States and the European Union. Many physicians and innovators in the United States cite a restrictive US FDA regulatory process as the reason for earlier and more rapid clinical advances in Europe. The FDA approval process mandates that a device be proved efficacious compared with a control or be substantially equivalent to a predicate device, whereas the European Union approval process mandates that the device perform its intended function. Stringent, peer-reviewed safety data have not been reported. However, after recent high-profile device failures, political pressure in both the United States and the European Union has favored more restrictive approval processes. Substantial reforms of the European Union process within the next 5 to 10 years will result in a more stringent approach to device regulation, similar to that of the FDA. Changes in the FDA regulatory process have been suggested but are not imminent.

  13. Touch-free, gesture-based control of medical devices and software based on the leap motion controller.

    Science.gov (United States)

    Mauser, Stanislas; Burgert, Oliver

    2014-01-01

    There are several intra-operative use cases which require the surgeon to interact with medical devices. We used the Leap Motion Controller as input device and implemented two use-cases: 2D-Interaction (e.g. advancing EPR data) and selection of a value (e.g. room illumination brightness). The gesture detection was successful and we mapped its output to several devices and systems.

  14. 75 FR 17143 - Draft Guidance for Industry and Food and Drug Administration Staff; Medical Devices; Neurological...

    Science.gov (United States)

    2010-04-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2009-D-0495] Draft Guidance for Industry and Food and Drug Administration Staff; Medical Devices; Neurological and Physical Medicine Device Guidance Documents; Availability AGENCY: Food and Drug Administration, HHS. ACTION...

  15. 75 FR 44267 - Draft Guidance for Industry and Food and Drug Administration Staff; Medical Devices; Neurological...

    Science.gov (United States)

    2010-07-28

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2009-N-0495] Draft Guidance for Industry and Food and Drug Administration Staff; Medical Devices; Neurological and Physical Medicine Device Guidance Document; Reopening of Comment Period AGENCY: Food and Drug...

  16. Constructing the informatics and information technology foundations of a medical device evaluation system: a report from the FDA unique device identifier demonstration.

    Science.gov (United States)

    Drozda, Joseph P; Roach, James; Forsyth, Thomas; Helmering, Paul; Dummitt, Benjamin; Tcheng, James E

    2018-02-01

    The US Food and Drug Administration (FDA) has recognized the need to improve the tracking of medical device safety and performance, with implementation of Unique Device Identifiers (UDIs) in electronic health information as a key strategy. The FDA funded a demonstration by Mercy Health wherein prototype UDIs were incorporated into its electronic information systems. This report describes the demonstration's informatics architecture. Prototype UDIs for coronary stents were created and implemented across a series of information systems, resulting in UDI-associated data flow from manufacture through point of use to long-term follow-up, with barcode scanning linking clinical data with UDI-associated device attributes. A reference database containing device attributes and the UDI Research and Surveillance Database (UDIR) containing the linked clinical and device information were created, enabling longitudinal assessment of device performance. The demonstration included many stakeholders: multiple Mercy departments, manufacturers, health system partners, the FDA, professional societies, the National Cardiovascular Data Registry, and information system vendors. The resulting system of systems is described in detail, including entities, functions, linkage between the UDIR and proprietary systems using UDIs as the index key, data flow, roles and responsibilities of actors, and the UDIR data model. The demonstration provided proof of concept that UDIs can be incorporated into provider and enterprise electronic information systems and used as the index key to combine device and clinical data in a database useful for device evaluation. Keys to success and challenges to achieving this goal were identified. Fundamental informatics principles were central to accomplishing the system of systems model. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  17. Wearable Devices in Medical Internet of Things: Scientific Research and Commercially Available Devices

    OpenAIRE

    Haghi, Mostafa; Thurow, Kerstin; Stoll, Regina

    2017-01-01

    Objectives Wearable devices are currently at the heart of just about every discussion related to the Internet of Things. The requirement for self-health monitoring and preventive medicine is increasing due to the projected dramatic increase in the number of elderly people until 2020. Developed technologies are truly able to reduce the overall costs for prevention and monitoring. This is possible by constantly monitoring health indicators in various areas, and in particular, wearable devices a...

  18. Biomedical devices and their applications

    CERN Document Server

    2004-01-01

    This volume introduces readers to the basic concepts and recent advances in the field of biomedical devices. The text gives a detailed account of novel developments in drug delivery, protein electrophoresis, estrogen mimicking methods and medical devices. It also provides the necessary theoretical background as well as describing a wide range of practical applications. The level and style make this book accessible not only to scientific and medical researchers but also to graduate students.

  19. [Discussion on Quality Evaluation Method of Medical Device During Life-Cycle in Operation Based on the Analytic Hierarchy Process].

    Science.gov (United States)

    Zheng, Caixian; Zheng, Kun; Shen, Yunming; Wu, Yunyun

    2016-01-01

    The content related to the quality during life-cycle in operation of medical device includes daily use, repair volume, preventive maintenance, quality control and adverse event monitoring. In view of this, the article aims at discussion on the quality evaluation method of medical devices during their life cycle in operation based on the Analytic Hierarchy Process (AHP). The presented method is proved to be effective by evaluating patient monitors as example. The method presented in can promote and guide the device quality control work, and it can provide valuable inputs to decisions about purchase of new device.

  20. Security and privacy qualities of medical devices: an analysis of FDA postmarket surveillance.

    Science.gov (United States)

    Kramer, Daniel B; Baker, Matthew; Ransford, Benjamin; Molina-Markham, Andres; Stewart, Quinn; Fu, Kevin; Reynolds, Matthew R

    2012-01-01

    Medical devices increasingly depend on computing functions such as wireless communication and Internet connectivity for software-based control of therapies and network-based transmission of patients' stored medical information. These computing capabilities introduce security and privacy risks, yet little is known about the prevalence of such risks within the clinical setting. We used three comprehensive, publicly available databases maintained by the Food and Drug Administration (FDA) to evaluate recalls and adverse events related to security and privacy risks of medical devices. Review of weekly enforcement reports identified 1,845 recalls; 605 (32.8%) of these included computers, 35 (1.9%) stored patient data, and 31 (1.7%) were capable of wireless communication. Searches of databases specific to recalls and adverse events identified only one event with a specific connection to security or privacy. Software-related recalls were relatively common, and most (81.8%) mentioned the possibility of upgrades, though only half of these provided specific instructions for the update mechanism. Our review of recalls and adverse events from federal government databases reveals sharp inconsistencies with databases at individual providers with respect to security and privacy risks. Recalls related to software may increase security risks because of unprotected update and correction mechanisms. To detect signals of security and privacy problems that adversely affect public health, federal postmarket surveillance strategies should rethink how to effectively and efficiently collect data on security and privacy problems in devices that increasingly depend on computing systems susceptible to malware.

  1. Fiscal 1999 achievement report on regional consortium research and development project. Regional consortium research field (Development of super-devices for medical equipment by 3-dimensional microstructure machining technology - 3rd year); 1999 nendo micro sanjigen kako gijutsu ni yoru iryo kikiyo super device no kaihatsu seika hokokusho (dai 3 nendo)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    In the development of micromechanisms, a highly efficient micromotor capable of outputting 25g/cm is developed, in which a DC motor, 4mm in diameter and 12.5mm in length, and a deceleration mechanism are combined. A technology is established of manufacturing microtubes 0.1mm in internal diameter of various materials for use with medical equipment. A direct cam screw type discharge mechanism for minute amounts is developed. It is now foreseen that a cartridge (air pressurized) discharge mechanism and a tube pump will be commercialized. A microjoint is developed with a built-in micro check valve for medicine flow channels. A microfilter is developed using a polypropylene hollow yarn membrane. A microsensor is developed, which responds to a 0.01-second change in flow rate at an error rate of {+-}3% or less. A microcomputer control system is test-produced. Newly developed devices are integrated for the test production of a portable device for sustained infusion of medicine, and the product is found to be superior to the existing systems. Also described are the utilization of various micromachining techniques. (NEDO)

  2. Safety problems with the use of medical equipment/devices

    NARCIS (Netherlands)

    Rademakers, C.

    2009-01-01

    In the past decennia medical technology has rapidly developed. Nowadays it plays an important role in all medical fields. It introduced technologic solutions for many medical problems and it definitely increased the possibilities in the medical field to increase the quality of life. However with

  3. Identification of proteins involved in the adhesionof Candida species to different medical devices.

    Science.gov (United States)

    Núñez-Beltrán, Arianna; López-Romero, Everardo; Cuéllar-Cruz, Mayra

    2017-06-01

    Adhesion is the first step for Candida species to form biofilms on medical devices implanted in the human host. Both the physicochemical nature of the biomaterial and cell wall proteins (CWP) of the pathogen play a determinant role in the process. While it is true that some CWP have been identified in vitro, little is known about the CWP of pathogenic species of Candida involved in adhesion. On this background, we considered it important to investigate the potential role of CWP of C. albicans, C. glabrata, C. krusei and C. parapsilosis in adhesion to different medical devices. Our results indicate that the four species strongly adher to polyvinyl chloride (PVC) devices, followed by polyurethane and finally by silicone. It was interesting to identify fructose-bisphosphate aldolase (Fba1) and enolase 1 (Eno1) as the CWP involved in adhesion of C. albicans, C. glabrata and C. krusei to PVC devices whereas phosphoglycerate kinase (Pgk) and Eno1 allow C. parapsilosis to adher to silicone-made implants. Results presented here suggest that these CWP participate in the initial event of adhesion and are probably followed by other proteins that covalently bind to the biomaterial thus providing conditions for biofilm formation and eventually the onset of infection. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Application of stereo-imaging technology to medical field.

    Science.gov (United States)

    Nam, Kyoung Won; Park, Jeongyun; Kim, In Young; Kim, Kwang Gi

    2012-09-01

    There has been continuous development in the area of stereoscopic medical imaging devices, and many stereoscopic imaging devices have been realized and applied in the medical field. In this article, we review past and current trends pertaining to the application stereo-imaging technologies in the medical field. We describe the basic principles of stereo vision and visual issues related to it, including visual discomfort, binocular disparities, vergence-accommodation mismatch, and visual fatigue. We also present a brief history of medical applications of stereo-imaging techniques, examples of recently developed stereoscopic medical devices, and patent application trends as they pertain to stereo-imaging medical devices. Three-dimensional (3D) stereo-imaging technology can provide more realistic depth perception to the viewer than conventional two-dimensional imaging technology. Therefore, it allows for a more accurate understanding and analysis of the morphology of an object. Based on these advantages, the significance of stereoscopic imaging in the medical field increases in accordance with the increase in the number of laparoscopic surgeries, and stereo-imaging technology plays a key role in the diagnoses of the detailed morphologies of small biological specimens. The application of 3D stereo-imaging technology to the medical field will help improve surgical accuracy, reduce operation times, and enhance patient safety. Therefore, it is important to develop more enhanced stereoscopic medical devices.

  5. HEALTH TECHNOLOGY ASSESSMENT OF MEDICAL DEVICES IN EUROPE: PROCESSES, PRACTICES, AND METHODS.

    Science.gov (United States)

    Fuchs, Sabine; Olberg, Britta; Panteli, Dimitra; Busse, Reinhard

    2016-01-01

    To review and compare current Health Technology Assessment (HTA) activities for medical devices (MDs) across European HTA institutions. A comprehensive approach was adopted to identify institutions involved in HTA in European countries. We systematically searched institutional Web sites and other online sources by using a structured tool to extract information on the role and link to decision making, structure, scope, process, methodological approach, and available HTA reports for each included institution. Information was obtained from eighty-four institutions, forty-seven of which were analyzed. Fifty-four methodological documents from twenty-three agencies in eighteen countries were identified. Only five agencies had separate documents for the assessment of MDs. A few agencies made separate provisions for the assessment of MDs in their general methods. The amount of publicly available HTA reports on MDs varied by device category and agency remit. Despite growing consensus on their importance and international initiatives, such as the EUnetHTA Core Model®, specific tools for the assessment of MDs are rarely developed and implemented at the national level. Separate additional signposts incorporated in existing general methods guides may be sufficient for the evaluation of MDs.

  6. 31 CFR 560.533 - Brokering sales of agricultural commodities, medicine, and medical devices.

    Science.gov (United States)

    2010-07-01

    ... technical data, software, or information) that are subject to license application requirements of another... IRANIAN TRANSACTIONS REGULATIONS Licenses, Authorizations and Statements of Licensing Policy § 560.533 Brokering sales of agricultural commodities, medicine, and medical devices. (a) General license for...

  7. A New Stethoscope Design with Unique Characteristics and Development in Medical Device

    Science.gov (United States)

    Ghahramanifar, M.; Haghani, M.; Ghadimi Moghadam, A.; Ghadimi Moghadam, A.K.

    2018-01-01

    As regards the significant role of stethoscopes in the diagnosis of congenital and adventitious heart diseases and prevention of irreparable complications of these diseases, the quality of hearing sound of these stethoscopes by a physician has a significant impact on the disease diagnosis. This device plays an important role in the early diagnosis of congenital heart and respiratory diseases and provides this feasibility since birth. Also, the importance of this device performance in the diagnosis of heart, cardiovascular and respiratory diseases at different age periods is not a secret. This new invented device, in comparison to a variety of available stethoscopes in the field of diagnosis, is capable of hearing the sound of a very high quality and cancelling the noise of sound that sometimes leads to wrong diagnosis or misdiagnosis. This new invented stethoscope is approved by cardiologists, lung and Infectious disease specialists as well as being registered under No. 78382 in Patent Islamic Republic of Iran. PMID:29732350

  8. A New Stethoscope Design with Unique Characteristics and Development in Medical Device.

    Science.gov (United States)

    Ghahramanifar, M; Haghani, M; Ghadimi Moghadam, A; Ghadimi Moghadam, A K

    2018-03-01

    As regards the significant role of stethoscopes in the diagnosis of congenital and adventitious heart diseases and prevention of irreparable complications of these diseases, the quality of hearing sound of these stethoscopes by a physician has a significant impact on the disease diagnosis. This device plays an important role in the early diagnosis of congenital heart and respiratory diseases and provides this feasibility since birth. Also, the importance of this device performance in the diagnosis of heart, cardiovascular and respiratory diseases at different age periods is not a secret. This new invented device, in comparison to a variety of available stethoscopes in the field of diagnosis, is capable of hearing the sound of a very high quality and cancelling the noise of sound that sometimes leads to wrong diagnosis or misdiagnosis. This new invented stethoscope is approved by cardiologists, lung and Infectious disease specialists as well as being registered under No. 78382 in Patent Islamic Republic of Iran.

  9. Sodium Hypochlorite Treatment and Nitinol Performance for Medical Devices

    Science.gov (United States)

    Weaver, J. D.; Gutierrez, E. J.; Nagaraja, S.; Stafford, P. R.; Sivan, S.; Di Prima, M.

    2017-09-01

    Processing of nitinol medical devices has evolved over the years as manufacturers have identified methods of reducing surface defects such as inclusions. One recent method proposes to soak nitinol medical devices in a 6% sodium hypochlorite (NaClO) solution as a means of identifying surface inclusions. Devices with surface inclusions could in theory then be removed from production because inclusions would interact with NaClO to form a visible black material on the nitinol surface. To understand the effects of an NaClO soak on performance, we compared as-received and NaClO-soaked nitinol wires with two different surface finishes (black oxide and electropolished). Pitting corrosion susceptibility was equivalent between the as-received and NaClO-soaked groups for both surface finishes. Nickel ion release increased in the NaClO-soaked group for black oxide nitinol, but was equivalent for electropolished nitinol. Fatigue testing revealed a lower fatigue life for NaClO-soaked black oxide nitinol at all alternating strains. With the exception of 0.83% alternating strain, NaClO-soaked and as-received electropolished nitinol had similar average fatigue life, but the NaClO-soaked group showed higher variability. NaClO-soaked electropolished nitinol had specimens with the lowest number of cycles to fracture for all alternating strains tested with the exception of the highest alternating strain 1.2%. The NaClO treatment identified only one specimen with surface inclusions and caused readily identifiable surface damage to the black oxide nitinol. Damage from the NaClO soak to electropolished nitinol surface also appears to have occurred and is likely the cause of the increased variability of the fatigue results. Overall, the NaClO soak appears to not lead to an improvement in nitinol performance and seems to be damaging to the nitinol surface in ways that may not be detectable with a simple visual inspection for black material on the nitinol surface.

  10. Cybersecurity vulnerabilities in medical devices: a complex environment and multifaceted problem

    Directory of Open Access Journals (Sweden)

    Williams PAH

    2015-07-01

    Full Text Available Patricia AH Williams, Andrew J Woodward eHealth Research Group and Security Research Institute, Edith Cowan University, Perth, WA, Australia Abstract: The increased connectivity to existing computer networks has exposed medical devices to cybersecurity vulnerabilities from which they were previously shielded. For the prevention of cybersecurity incidents, it is important to recognize the complexity of the operational environment as well as to catalog the technical vulnerabilities. Cybersecurity protection is not just a technical issue; it is a richer and more intricate problem to solve. A review of the factors that contribute to such a potentially insecure environment, together with the identification of the vulnerabilities, is important for understanding why these vulnerabilities persist and what the solution space should look like. This multifaceted problem must be viewed from a systemic perspective if adequate protection is to be put in place and patient safety concerns addressed. This requires technical controls, governance, resilience measures, consolidated reporting, context expertise, regulation, and standards. It is evident that a coordinated, proactive approach to address this complex challenge is essential. In the interim, patient safety is under threat. Keywords: cybersecurity, security, safety, wireless, risk, medical devices

  11. A workshop on developing risk assessment methods for medical use of radioactive material. Volume 1: Summary

    Energy Technology Data Exchange (ETDEWEB)

    Tortorelli, J.P. [ed.] [Lockheed Idaho Technologies Co., Idaho Falls, ID (United States)

    1995-08-01

    A workshop was held at the Idaho National Engineering Laboratory, August 16--18, 1994 on the topic of risk assessment on medical devices that use radioactive isotopes. Its purpose was to review past efforts to develop a risk assessment methodology to evaluate these devices, and to develop a program plan and a scoping document for future methodology development. This report contains a summary of that workshop. Participants included experts in the fields of radiation oncology, medical physics, risk assessment, human-error analysis, and human factors. Staff from the US Nuclear Regulatory Commission (NRC) associated with the regulation of medical uses of radioactive materials and with research into risk-assessment methods participated in the workshop. The workshop participants concurred in NRC`s intended use of risk assessment as an important technology in the development of regulations for the medical use of radioactive material and encouraged the NRC to proceed rapidly with a pilot study. Specific recommendations are included in the executive summary and the body of this report. An appendix contains the 8 papers presented at the conference: NRC proposed policy statement on the use of probabilistic risk assessment methods in nuclear regulatory activities; NRC proposed agency-wide implementation plan for probabilistic risk assessment; Risk evaluation of high dose rate remote afterloading brachytherapy at a large research/teaching institution; The pros and cons of using human reliability analysis techniques to analyze misadministration events; Review of medical misadministration event summaries and comparison of human error modeling; Preliminary examples of the development of error influences and effects diagrams to analyze medical misadministration events; Brachytherapy risk assessment program plan; and Principles of brachytherapy quality assurance.

  12. A workshop on developing risk assessment methods for medical use of radioactive material. Volume 1: Summary

    International Nuclear Information System (INIS)

    Tortorelli, J.P.

    1995-08-01

    A workshop was held at the Idaho National Engineering Laboratory, August 16--18, 1994 on the topic of risk assessment on medical devices that use radioactive isotopes. Its purpose was to review past efforts to develop a risk assessment methodology to evaluate these devices, and to develop a program plan and a scoping document for future methodology development. This report contains a summary of that workshop. Participants included experts in the fields of radiation oncology, medical physics, risk assessment, human-error analysis, and human factors. Staff from the US Nuclear Regulatory Commission (NRC) associated with the regulation of medical uses of radioactive materials and with research into risk-assessment methods participated in the workshop. The workshop participants concurred in NRC's intended use of risk assessment as an important technology in the development of regulations for the medical use of radioactive material and encouraged the NRC to proceed rapidly with a pilot study. Specific recommendations are included in the executive summary and the body of this report. An appendix contains the 8 papers presented at the conference: NRC proposed policy statement on the use of probabilistic risk assessment methods in nuclear regulatory activities; NRC proposed agency-wide implementation plan for probabilistic risk assessment; Risk evaluation of high dose rate remote afterloading brachytherapy at a large research/teaching institution; The pros and cons of using human reliability analysis techniques to analyze misadministration events; Review of medical misadministration event summaries and comparison of human error modeling; Preliminary examples of the development of error influences and effects diagrams to analyze medical misadministration events; Brachytherapy risk assessment program plan; and Principles of brachytherapy quality assurance

  13. Medical devices made into weapons by prisoners: an unrecognized risk.

    Science.gov (United States)

    Hayden, J W; Laney, C; Kellermann, A L

    1995-12-01

    The alteration of a knee immobilizer into a sharp weapon by a prisoner prompted us to survey neighboring penal institutions to determine the frequency of such events. We mailed a nine-item survey to all detention facilities in Tennessee, Arkansas, and Mississippi. A second survey was sent to nonresponding institutions 6 weeks after the initial mailing. The Regional Medical Center at Memphis, the designated facility for evaluation and treatment of prisoners from the county jail and state penitentiary. Survey respondents included 25 state penitentiaries, 31 county jails, 1 state minimum-security facility, 1 state maximum-security facility, 1 work-release center, 1 county detention center for drunken-driving offenders, and 1 federal penitentiary. Of the 81 institutions surveyed, 77% responded to one of the two mailings. Forty percent responded in the affirmative when asked whether stolen or unauthorized medical equipment from outside their institutions had been discovered among inmates. When respondents were questioned as to whether medical equipment, prescribed or not, had been used or altered in a criminal manner, 34% responded "yes." Medications and medical appliances were listed in the responses. A survey of 81 local and neighboring penal institutions in a three-state area revealed that the illicit use of medicine and medical devices by prisoners is a legitimate safety concern of prison personnel and health care workers when medical care for inmates must be sought outside the security of their institutions. The modification of medical equipment into weapons by incarcerated patients, although clearly recognized as a security and safety problem by police authorities, appears to be unappreciated by health care workers providing episodic care to inmates.

  14. Security and privacy issues in implantable medical devices: A comprehensive survey.

    Science.gov (United States)

    Camara, Carmen; Peris-Lopez, Pedro; Tapiador, Juan E

    2015-06-01

    Bioengineering is a field in expansion. New technologies are appearing to provide a more efficient treatment of diseases or human deficiencies. Implantable Medical Devices (IMDs) constitute one example, these being devices with more computing, decision making and communication capabilities. Several research works in the computer security field have identified serious security and privacy risks in IMDs that could compromise the implant and even the health of the patient who carries it. This article surveys the main security goals for the next generation of IMDs and analyzes the most relevant protection mechanisms proposed so far. On the one hand, the security proposals must have into consideration the inherent constraints of these small and implanted devices: energy, storage and computing power. On the other hand, proposed solutions must achieve an adequate balance between the safety of the patient and the security level offered, with the battery lifetime being another critical parameter in the design phase. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. 76 FR 7222 - Medical Device Innovation Initiative; Public Meeting; Request for Comments

    Science.gov (United States)

    2011-02-09

    ... public meeting will be provided on a space-available basis beginning at 7 a.m. Non-U.S. citizens are... The United States is the global leader in medical device innovation and CDRH is committed to assuring... public health. CDRH is responsible for advancing public health and facilitating innovation to help bring...

  16. Public Use of Mobile Medical Applications: A Case Study on Cloud-Based Medical Service of Taiwan.

    Science.gov (United States)

    Lu, Chen-Luan; Yan, Yu-Hua

    2016-01-01

    The use of smart mobile devices has been getting increasingly popular. The focus of this study is an attempt to explore the development of mobile medical App by medical centers and regional hospitals of Taiwan and the function of the App for comparison. The results show indicated that many hospitals developed Apps for the public for mobile medical service, of which 26 medical centers (100%) and 72 regional hospitals (84.7%) availed appointment making service via Apps. The result indicated variance at significant level (p < 0.01). There are 23 medical centers (88.5%) and 74 regional hospitals (87.1%) availed Apps for checking service progress. The result indicated insignificant variance level (p > 0.01). We can see that mobile medical service is gradually emerging as a vital issue. Yet, this is a new domain in medical service. With the mushrooming of medical applications in smart mobile devices, the medical service system is expected to be installed in these devices to enhance interactive mode of operation and inquiry services, such as medication and inquiries into physical examination results. By then, people can learn the status of their health with this system.

  17. Grave fraudulence in medical device research: a narrative review of the PIN seeding study for the Pinnacle hip system.

    Science.gov (United States)

    Steffen, Joan E; Fassler, Ella A; Reardon, Kevin J; Egilman, David S

    2018-01-01

    In 2001, DePuy, a wholly-owned subsidiary of Johnson & Johnson (J&J/DePuy), initiated a seeding study called the "Multi-center, Prospective, Clinical Evaluation of Pinnacle Acetabular Implants in Total Hip Arthroplasty" (PIN Study). J&J/DePuy designed this study to develop new business opportunities during the launch of their Pinnacle Hip System (PHS) and generate survivorship data for marketing. This article, the first review of a seeding trial for a medical device, examines internal company documents relating to the PIN Study; the analysis herein focuses on the integrity of J&J/DePuy's research practices in conception, implementation, and analysis. J&J/DePuy violated the study protocol and manipulated data; consented participants in violation of standards protecting human subjects; and did not secure Institutional Review Board approval for all study sites. J&J/DePuy used PIN Study results as the "fundamental selling point" for the PHS. Medical device seeding trials are distinct from previously-documented pharmaceutical seeding trials because companies can profit directly from device sales and because these studies may be the first clinical evaluation of the device (as was the case for the PIN Study). Seeding trials are malleable marketing projects, not rigorous scientific studies. Regulatory bodies, physicians, and others should be vigilant for persuasive marketing accounts disguised as science.

  18. Simulation of leakage current measurement on medical devices using helmholtz coil configuration with different current flow

    Science.gov (United States)

    Sutanto, E.; Chandra, F.; Dinata, R.

    2017-05-01

    Leakage current measurement which can follow IEC standard for medical device is one of many challenges to be answered. The IEC 60601-1 has defined that the limit for a leakage current for Medical Device can be as low as 10 µA and as high as 500 µA, depending on which type of contact (applied part) connected to the patient. Most people are using ELCB (Earth-leakage circuit breaker) for safety purpose as this is the most common and available safety device in market. One type of ELCB devices is RCD (Residual Current Device) and this RCD type can measure the leakage current directly. This work will show the possibility on how Helmholtz Coil Configuration can be made to be like the RCD. The possibility is explored by comparing the magnetic field formula from each device, then it proceeds with a simulation using software EJS (Easy Java Simulation). The simulation will make sure the concept of magnetic field current cancellation follows the RCD concept. Finally, the possibility of increasing the measurement’s sensitivity is also analyzed. The sensitivity is needed to see the possibility on reaching the minimum leakage current limit defined by IEC, 0.01mA.

  19. Simulation of leakage current measurement on medical devices using helmholtz coil configuration with different current flow

    International Nuclear Information System (INIS)

    Sutanto, E; Chandra, F; Dinata, R

    2017-01-01

    Leakage current measurement which can follow IEC standard for medical device is one of many challenges to be answered. The IEC 60601-1 has defined that the limit for a leakage current for Medical Device can be as low as 10 µA and as high as 500 µA, depending on which type of contact (applied part) connected to the patient. Most people are using ELCB (Earth-leakage circuit breaker) for safety purpose as this is the most common and available safety device in market. One type of ELCB devices is RCD (Residual Current Device) and this RCD type can measure the leakage current directly. This work will show the possibility on how Helmholtz Coil Configuration can be made to be like the RCD. The possibility is explored by comparing the magnetic field formula from each device, then it proceeds with a simulation using software EJS (Easy Java Simulation). The simulation will make sure the concept of magnetic field current cancellation follows the RCD concept. Finally, the possibility of increasing the measurement’s sensitivity is also analyzed. The sensitivity is needed to see the possibility on reaching the minimum leakage current limit defined by IEC, 0.01mA. (paper)

  20. Security and Privacy Qualities of Medical Devices: An Analysis of FDA Postmarket Surveillance

    Science.gov (United States)

    Kramer, Daniel B.; Baker, Matthew; Ransford, Benjamin; Molina-Markham, Andres; Stewart, Quinn; Fu, Kevin; Reynolds, Matthew R.

    2012-01-01

    Background Medical devices increasingly depend on computing functions such as wireless communication and Internet connectivity for software-based control of therapies and network-based transmission of patients’ stored medical information. These computing capabilities introduce security and privacy risks, yet little is known about the prevalence of such risks within the clinical setting. Methods We used three comprehensive, publicly available databases maintained by the Food and Drug Administration (FDA) to evaluate recalls and adverse events related to security and privacy risks of medical devices. Results Review of weekly enforcement reports identified 1,845 recalls; 605 (32.8%) of these included computers, 35 (1.9%) stored patient data, and 31 (1.7%) were capable of wireless communication. Searches of databases specific to recalls and adverse events identified only one event with a specific connection to security or privacy. Software-related recalls were relatively common, and most (81.8%) mentioned the possibility of upgrades, though only half of these provided specific instructions for the update mechanism. Conclusions Our review of recalls and adverse events from federal government databases reveals sharp inconsistencies with databases at individual providers with respect to security and privacy risks. Recalls related to software may increase security risks because of unprotected update and correction mechanisms. To detect signals of security and privacy problems that adversely affect public health, federal postmarket surveillance strategies should rethink how to effectively and efficiently collect data on security and privacy problems in devices that increasingly depend on computing systems susceptible to malware. PMID:22829874

  1. The future of academic innovation in the field of medical devices: is innovation still possible in orthopedics?

    Science.gov (United States)

    Courvoisier, Aurélien

    2016-09-01

    Academic research is essential to bring disruptive innovation on medical devices market because the risk-taking is too high for companies and their investors. Performing clinical trials is essential to technical files but no one wants to accept responsibility for implanted off-label devices. The paper explains the academic process for innovation. We see that academic research depends, at the end, on the motivation of companies to develop a product. The key to innovation stands in the early collaboration between the surgeons, the research teams and the companies in a project. Innovation is a good idea supported by the expertise of the right people at the right moment. In orthopaedics, we need, more than ever, to stay focused on the patient benefits.

  2. FDA (Food and Drug Administration) compliance program guidance manual and updates (FY 86). Section 4. Medical and radiological devices. Irregular report

    International Nuclear Information System (INIS)

    1986-01-01

    The FDA Compliance Program Guidance Manual provides a system for issuing and filing program plans and instructions directed to Food and Drug Administration Field operations for project implementation. Section IV provides those chapters of the Compliance Program Guidance Manual which pertain to the areas of medical and radiological devices. Some of the areas of coverage include laser and sunlamp standards inspections, compliance testing of various radiation-emitting products such as television receivers and microwave ovens, emergency response planning and policy, premarket approval and device manufacturers inspections, device problem reporting, sterilization of devices, and consumer education programs on medical and radiological devices

  3. 76 FR 45826 - Medical Device User Fee Rates for Fiscal Year 2012

    Science.gov (United States)

    2011-08-01

    ... paper check: All paper checks must be in U.S. currency from a U.S. bank and made payable to the Food and... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0542] Medical Device User Fee Rates for Fiscal Year 2012 AGENCY: Food and Drug Administration, HHS. ACTION...

  4. Intelligent Medical Systems for Aerospace Emergency Medical Services

    Science.gov (United States)

    Epler, John; Zimmer, Gary

    2004-01-01

    The purpose of this project is to develop a portable, hands free device for emergency medical decision support to be used in remote or confined settings by non-physician providers. Phase I of the project will entail the development of a voice-activated device that will utilize an intelligent algorithm to provide guidance in establishing an airway in an emergency situation. The interactive, hands free software will process requests for assistance based on verbal prompts and algorithmic decision-making. The device will allow the CMO to attend to the patient while receiving verbal instruction. The software will also feature graphic representations where it is felt helpful in aiding in procedures. We will also develop a training program to orient users to the algorithmic approach, the use of the hardware and specific procedural considerations. We will validate the efficacy of this mode of technology application by testing in the Johns Hopkins Department of Emergency Medicine. Phase I of the project will focus on the validation of the proposed algorithm, testing and validation of the decision making tool and modifications of medical equipment. In Phase 11, we will produce the first generation software for hands-free, interactive medical decision making for use in acute care environments.

  5. 75 FR 15439 - Food and Drug Administration/Xavier University Global Medical Device Conference

    Science.gov (United States)

    2010-03-29

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0001] Food and Drug Administration/Xavier University Global Medical Device Conference AGENCY: Food and Drug Administration, HHS. ACTION: Notice of public conference. SUMMARY: The Food and Drug Administration (FDA...

  6. 78 FR 15957 - Food and Drug Administration/Xavier University Global Medical Device Conference

    Science.gov (United States)

    2013-03-13

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-0001] Food and Drug Administration/Xavier University Global Medical Device Conference AGENCY: Food and Drug Administration, HHS. ACTION: Notice of public conference. SUMMARY: The Food and Drug Administration (FDA...

  7. 77 FR 10537 - Food and Drug Administration/Xavier University Global Medical Device Conference

    Science.gov (United States)

    2012-02-22

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-N-0001] Food and Drug Administration/Xavier University Global Medical Device Conference AGENCY: Food and Drug Administration, HHS. ACTION: Notice of public conference. SUMMARY: The Food and Drug Administration (FDA...

  8. Antimicrobial Treatment of Polymeric Medical Devices by Silver Nanomaterials and Related Technology.

    Science.gov (United States)

    Polívková, Markéta; Hubáček, Tomáš; Staszek, Marek; Švorčík, Václav; Siegel, Jakub

    2017-02-15

    Antimicrobial biocompatible polymers form a group of highly desirable materials in medicinal technology that exhibit interesting thermal and mechanical properties, and high chemical resistance. There are numerous types of polymers with antimicrobial activity or antimicrobial properties conferred through their proper modification. In this review, we focus on the second type of polymers, especially those whose antimicrobial activity is conferred by nanotechnology. Nanotechnology processing is a developing area that exploits the antibacterial effects of broad-scale compounds, both organic and inorganic, to form value-added medical devices. This work gives an overview of nanostructured antimicrobial agents, especially silver ones, used together with biocompatible polymers as effective antimicrobial composites in healthcare. The bactericidal properties of non-conventional antimicrobial agents are compared with those of conventional ones and the advantages and disadvantages are discussed.

  9. Antimicrobial Treatment of Polymeric Medical Devices by Silver Nanomaterials and Related Technology

    Directory of Open Access Journals (Sweden)

    Markéta Polívková

    2017-02-01

    Full Text Available Antimicrobial biocompatible polymers form a group of highly desirable materials in medicinal technology that exhibit interesting thermal and mechanical properties, and high chemical resistance. There are numerous types of polymers with antimicrobial activity or antimicrobial properties conferred through their proper modification. In this review, we focus on the second type of polymers, especially those whose antimicrobial activity is conferred by nanotechnology. Nanotechnology processing is a developing area that exploits the antibacterial effects of broad-scale compounds, both organic and inorganic, to form value-added medical devices. This work gives an overview of nanostructured antimicrobial agents, especially silver ones, used together with biocompatible polymers as effective antimicrobial composites in healthcare. The bactericidal properties of non-conventional antimicrobial agents are compared with those of conventional ones and the advantages and disadvantages are discussed.

  10. Strategy on biological evaluation for biodegradable/absorbable materials and medical devices.

    Science.gov (United States)

    Liu, Chenghu; Luo, Hongyu; Wan, Min; Hou, Li; Wang, Xin; Shi, Yanping

    2018-01-01

    During the last two decades, biodegradable/absorbable materials which have many benefits over conventional implants are being sought in clinical practices. However, to date, it still remains obscure for us to perform full physic-chemical characterization and biological risk assessment for these materials and related devices due to their complex design and coherent processing. In this review, based on the art of knowledge for biodegradable/absorbable materials and biological risk assessment, we demonstrated some promising strategies to establish and improve the current biological evaluation systems for these biodegradable/absorbable materials and related medical devices.

  11. 3D printing for health & wealth: Fabrication of custom-made medical devices through additive manufacturing

    Science.gov (United States)

    Colpani, Alessandro; Fiorentino, Antonio; Ceretti, Elisabetta

    2018-05-01

    Additive Manufacturing (AM) differs from traditional manufacturing technologies by its ability to handle complex shapes with great design flexibility. These features make the technique suitable to fabricate customized components, particularly answering specific custom needs. Although AM mainly referred to prototyping, nowadays the interest in direct manufacturing of actual parts is growing. This article shows the application of AM within the project 3DP-4H&W (3D Printing for Health & Wealth) which involves engineers and physicians for developing pediatric custom-made medical devices to enhance the fulfilling of the patients specific needs. In the project, two types of devices made of a two-component biocompatible silicone are considered. The first application (dental field) consists in a device for cleft lip and palate. The second one (audiological field) consists in an acoustic prosthesis. The geometries of the devices are based on the anatomy of the patient that is obtained through a 3D body scan process. For both devices, two different approaches were planned, namely direct AM and indirect Rapid Tooling (RT). In particular, direct AM consists in the FDM processing of silicone, while RT consists in molds FDM fabrication followed by silicone casting. This paper presents the results of the RT method that is articulated in different phases: the acquisition of the geometry to be realized, the design of the molds taking into account the casting feasibility (as casting channel, vents, part extraction), the realization of molds produced through AM, molds surface chemical finishing, pouring and curing of the silicone. The fabricated devices were evaluated by the physicians team that confirmed the effectiveness of the proposed procedure in fabricating the desired devices. Moreover, the procedure can be used as a general method to extend the range of applications to any custom-made device for anatomic districts, especially where complex shapes are present (as tracheal or

  12. Identifying optimal postmarket surveillance strategies for medical and surgical devices: implications for policy, practice and research.

    Science.gov (United States)

    Gagliardi, Anna R; Umoquit, Muriah; Lehoux, Pascale; Ross, Sue; Ducey, Ariel; Urbach, David R

    2013-03-01

    Non-drug technologies offer many benefits, but have been associated with adverse events, prompting calls for improved postmarket surveillance. There is little empirical research to guide the development of such a system. The purpose of this study was to identify optimal postmarket surveillance strategies for medical and surgical devices. Qualitative methods were used for sampling, data collection and analysis. Stakeholders from Canada and the USA representing different roles and perspectives were first interviewed to identify examples and characteristics of different surveillance strategies. These stakeholders and others they recommended were then assembled at a 1-day nominal group meeting to discuss and prioritise the components of a postmarket device surveillance system, and research needed to achieve such a system. Consultations were held with 37 participants, and 47 participants attended the 1-day meeting. They recommended a multicomponent system including reporting by facilities, clinicians and patients, supported with some external surveillance for validation and real-time trials for high-risk devices. Many considerations were identified that constitute desirable characteristics of, and means by which to implement such a system. An overarching network was envisioned to broker linkages, establish a shared minimum dataset, and support communication and decision making. Numerous research questions were identified, which could be pursued in tandem with phased implementation of the system. These findings provide unique guidance for establishing a device safety network that is based on existing initiatives, and could be expanded and evaluated in a prospective, phased fashion as it was developed.

  13. Personalized biomedical devices & systems for healthcare applications

    Science.gov (United States)

    Chen, I.-Ming; Phee, Soo Jay; Luo, Zhiqiang; Lim, Chee Kian

    2011-03-01

    With the advancement in micro- and nanotechnology, electromechanical components and systems are getting smaller and smaller and gradually can be applied to the human as portable, mobile and even wearable devices. Healthcare industry have started to benefit from this technology trend by providing more and more miniature biomedical devices for personalized medical treatments in order to obtain better and more accurate outcome. This article introduces some recent development in non-intrusive and intrusive biomedical devices resulted from the advancement of niche miniature sensors and actuators, namely, wearable biomedical sensors, wearable haptic devices, and ingestible medical capsules. The development of these devices requires carful integration of knowledge and people from many different disciplines like medicine, electronics, mechanics, and design. Furthermore, designing affordable devices and systems to benefit all mankind is a great challenge ahead. The multi-disciplinary nature of the R&D effort in this area provides a new perspective for the future mechanical engineers.

  14. [Introduction of Quality Management System Audit in Medical Device Single Audit Program].

    Science.gov (United States)

    Wen, Jing; Xiao, Jiangyi; Wang, Aijun

    2018-01-30

    The audit of the quality management system in the medical device single audit program covers the requirements of several national regulatory authorities, which has a very important reference value. This paper briefly described the procedures and contents of this audit. Some enlightenment on supervision and inspection are discussed in China, for reference by the regulatory authorities and auditing organizations.

  15. Residual Isocyanates in Medical Devices and Products: A Qualitative and Quantitative Assessment

    Directory of Open Access Journals (Sweden)

    Gillian Franklin

    2016-01-01

    Full Text Available We conducted a pilot qualitative and quantitative assessment of residual isocyanates and their potential initial exposures in neonates, as little is known about their contact effect. After a neonatal intensive care unit (NICU stockroom inventory, polyurethane (PU and PU foam (PUF devices and products were qualitatively evaluated for residual isocyanates using Surface SWYPE ™ . Those containing isocyanates were quantitatively tested for methylene diphenyl diisocyanate (MDI species, using UPLC-UV-MS/MS method. Ten of 37 products and devices tested, indicated both free and bound residual surface isocyanates; PU/PUF pieces contained aromatic isocyanates; one product contained aliphatic isocyanates. Overall, quantified mean MDI concentrations were low (4,4‘-MDI = 0.52 to 140.1 pg/mg and (2,4‘-MDI = 0.01 to 4.48 pg/mg. The 4,4‘-MDI species had the highest measured concentration (280 pg/mg. Commonly used medical devices/products contain low, but measurable concentrations of residual isocyanates. Quantifying other isocyanate species and neonatal skin exposure to isocyanates from these devices and products requires further investigation.

  16. 78 FR 21612 - Medical Device Classification Product Codes; Guidance for Industry and Food and Drug...

    Science.gov (United States)

    2013-04-11

    ... driving force for CDRH's internal organizational structure as well. These Panels were established with the... guidance represents the Agency's current thinking on medical device classification product codes. It does...

  17. Development of a Virtual Guitar using Haptic Device

    OpenAIRE

    田村,真晴; 山下,英生

    2009-01-01

    In recent years, a haptic device that output power as one of the computer output devices has been developed. We can get the feeling that we really touch the material through a sensor of haptic device when we touch a material simulated in a computer. In this research, a virtual guitar in which the feeling playing guitar and the sound volume are changed by adjusting power to input with a haptic device was developed. With the haptic device we feel as if we play a genuine guitar. Moreover, it see...

  18. An extended protocol for usability validation of medical devices: Research design and reference model.

    Science.gov (United States)

    Schmettow, Martin; Schnittker, Raphaela; Schraagen, Jan Maarten

    2017-05-01

    This paper proposes and demonstrates an extended protocol for usability validation testing of medical devices. A review of currently used methods for the usability evaluation of medical devices revealed two main shortcomings. Firstly, the lack of methods to closely trace the interaction sequences and derive performance measures. Secondly, a prevailing focus on cross-sectional validation studies, ignoring the issues of learnability and training. The U.S. Federal Drug and Food Administration's recent proposal for a validation testing protocol for medical devices is then extended to address these shortcomings: (1) a novel process measure 'normative path deviations' is introduced that is useful for both quantitative and qualitative usability studies and (2) a longitudinal, completely within-subject study design is presented that assesses learnability, training effects and allows analysis of diversity of users. A reference regression model is introduced to analyze data from this and similar studies, drawing upon generalized linear mixed-effects models and a Bayesian estimation approach. The extended protocol is implemented and demonstrated in a study comparing a novel syringe infusion pump prototype to an existing design with a sample of 25 healthcare professionals. Strong performance differences between designs were observed with a variety of usability measures, as well as varying training-on-the-job effects. We discuss our findings with regard to validation testing guidelines, reflect on the extensions and discuss the perspectives they add to the validation process. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Implementation of a low-cost mobile devices to support medical diagnosis.

    Science.gov (United States)

    García Sánchez, Carlos; Botella Juan, Guillermo; Ayuso Márquez, Fermín; González Rodríguez, Diego; Prieto-Matías, Manuel; Tirado Fernández, Francisco

    2013-01-01

    Medical imaging has become an absolutely essential diagnostic tool for clinical practices; at present, pathologies can be detected with an earliness never before known. Its use has not only been relegated to the field of radiology but also, increasingly, to computer-based imaging processes prior to surgery. Motion analysis, in particular, plays an important role in analyzing activities or behaviors of live objects in medicine. This short paper presents several low-cost hardware implementation approaches for the new generation of tablets and/or smartphones for estimating motion compensation and segmentation in medical images. These systems have been optimized for breast cancer diagnosis using magnetic resonance imaging technology with several advantages over traditional X-ray mammography, for example, obtaining patient information during a short period. This paper also addresses the challenge of offering a medical tool that runs on widespread portable devices, both on tablets and/or smartphones to aid in patient diagnostics.

  20. Implementation of a Low-Cost Mobile Devices to Support Medical Diagnosis

    Directory of Open Access Journals (Sweden)

    Carlos García Sánchez

    2013-01-01

    Full Text Available Medical imaging has become an absolutely essential diagnostic tool for clinical practices; at present, pathologies can be detected with an earliness never before known. Its use has not only been relegated to the field of radiology but also, increasingly, to computer-based imaging processes prior to surgery. Motion analysis, in particular, plays an important role in analyzing activities or behaviors of live objects in medicine. This short paper presents several low-cost hardware implementation approaches for the new generation of tablets and/or smartphones for estimating motion compensation and segmentation in medical images. These systems have been optimized for breast cancer diagnosis using magnetic resonance imaging technology with several advantages over traditional X-ray mammography, for example, obtaining patient information during a short period. This paper also addresses the challenge of offering a medical tool that runs on widespread portable devices, both on tablets and/or smartphones to aid in patient diagnostics.

  1. Fiscal 1998 achievement report on regional consortium research and development project. Venture business raising type regional consortium - small business creating base type (Research and development of Peltier actuating device-aided advanced medical and welfare systems - 2nd year); 1998 nendo Peltier undo soshi wo mochiita kodo iryo fukushi system no kenkyu kaihatsu seika hokokusho. 2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    Efforts are made to develop a new Peltier actuating device by amalgamating a Peltier device and shape memory alloy and to apply the product to medical and welfare activities. In the development of active movement control for a Peltier actuating device, a multiaxial control system is developed, and a success is attained in high-speed and high-precision control of temperature and in current- and voltage-aided control of the behavior. In the development of an active actuator for catheters, an active catheter is developed for the first time, capable of performing twisting and bending simultaneously. In the development of an artificial heart catheter, an approximately 10cm-long Peltier actuating device is manufactured to serve as an artificial heart module, and a controller is developed to drive the module at the frequency of approximately 0.5Hz. In the development of shape memory alloys and Peltier devices for normal temperature actuation, the impact is examined of the addition of a third element on the transformation temperature and shape memory characteristics. Research and development is also carried out for element technologies for using a Peltier actuating device as an artificial muscle. (NEDO)

  2. The Use of Nanomaterials and Microfluidics in Medical Diagnostics

    DEFF Research Database (Denmark)

    Ashley, Jon; Sun, Yi

    2018-01-01

    and manipulation of materials, systems, and devices at the nanometer scale. The development of nanomaterials and nano-devices can be classified into two general approaches. The top down approach deals exclusively with developing nanostructures through machining, templating and lithographic techniques and refers...... nanotechnology followed by a brief summary of bottom-up approaches to developing nanomaterials and their use in medical diagnostics. Then a discussion on the top-down approach will focus on nano-devices, methods for fabrication and the applications of these devices in medical diagnostics. The chapter will go...

  3. Do we have to Include HCI Issues in Clinical Trials of Medical Devices?

    DEFF Research Database (Denmark)

    Nielsen, Lene; Christensen, Lars Rune; Sabers, Anne

    2017-01-01

    Digital devices play an important role in medical treatment and will in the future play a larger role in connection to cures of health-related issues. Traditionally medicine has been tested by clinical double blind, randomized trials to document the efficacy and safety profile. When it comes to t...

  4. Definition of information technology architectures for continuous data management and medical device integration in diabetes.

    Science.gov (United States)

    Hernando, M Elena; Pascual, Mario; Salvador, Carlos H; García-Sáez, Gema; Rodríguez-Herrero, Agustín; Martínez-Sarriegui, Iñaki; Gómez, Enrique J

    2008-09-01

    The growing availability of continuous data from medical devices in diabetes management makes it crucial to define novel information technology architectures for efficient data storage, data transmission, and data visualization. The new paradigm of care demands the sharing of information in interoperable systems as the only way to support patient care in a continuum of care scenario. The technological platforms should support all the services required by the actors involved in the care process, located in different scenarios and managing diverse information for different purposes. This article presents basic criteria for defining flexible and adaptive architectures that are capable of interoperating with external systems, and integrating medical devices and decision support tools to extract all the relevant knowledge to support diabetes care.

  5. Preparation and Characterization of an Advanced Medical Device for Bone Regeneration

    OpenAIRE

    Dorati, Rossella; Colonna, Claudia; Genta, Ida; Bruni, Giovanna; Visai, Livia; Conti, Bice

    2013-01-01

    Tridimensional scaffolds can promote bone regeneration as a framework supporting the migration of cells from the surrounding tissue into the damaged tissue and as delivery systems for the controlled or prolonged release of cells, genes, and growth factors. The goal of the work was to obtain an advanced medical device for bone regeneration through coating a decellularized and deproteinized bone matrix of bovine origin with a biodegradable, biocompatible polymer, to improve the cell engraftment...

  6. Wearable Device Control Platform Technology for Network Application Development

    Directory of Open Access Journals (Sweden)

    Heejung Kim

    2016-01-01

    Full Text Available Application development platform is the most important environment in IT industry. There are a variety of platforms. Although the native development enables application to optimize, various languages and software development kits need to be acquired according to the device. The coexistence of smart devices and platforms has rendered the native development approach time and cost consuming. Cross-platform development emerged as a response to these issues. These platforms generate applications for multiple devices based on web languages. Nevertheless, development requires additional implementation based on a native language because of the coverage and functions of supported application programming interfaces (APIs. Wearable devices have recently attracted considerable attention. These devices only support Bluetooth-based interdevice communication, thereby making communication and device control impossible beyond a certain range. We propose Network Application Agent (NetApp-Agent in order to overcome issues. NetApp-Agent based on the Cordova is a wearable device control platform for the development of network applications, controls input/output functions of smartphones and wearable/IoT through the Cordova and Native API, and enables device control and information exchange by external users by offering a self-defined API. We confirmed the efficiency of the proposed platform through experiments and a qualitative assessment of its implementation.

  7. Security Mechanism Based on Hospital Authentication Server for Secure Application of Implantable Medical Devices

    Science.gov (United States)

    2014-01-01

    After two recent security attacks against implantable medical devices (IMDs) have been reported, the privacy and security risks of IMDs have been widely recognized in the medical device market and research community, since the malfunctioning of IMDs might endanger the patient's life. During the last few years, a lot of researches have been carried out to address the security-related issues of IMDs, including privacy, safety, and accessibility issues. A physician accesses IMD through an external device called a programmer, for diagnosis and treatment. Hence, cryptographic key management between IMD and programmer is important to enforce a strict access control. In this paper, a new security architecture for the security of IMDs is proposed, based on a 3-Tier security model, where the programmer interacts with a Hospital Authentication Server, to get permissions to access IMDs. The proposed security architecture greatly simplifies the key management between IMDs and programmers. Also proposed is a security mechanism to guarantee the authenticity of the patient data collected from IMD and the nonrepudiation of the physician's treatment based on it. The proposed architecture and mechanism are analyzed and compared with several previous works, in terms of security and performance. PMID:25276797

  8. Security mechanism based on Hospital Authentication Server for secure application of implantable medical devices.

    Science.gov (United States)

    Park, Chang-Seop

    2014-01-01

    After two recent security attacks against implantable medical devices (IMDs) have been reported, the privacy and security risks of IMDs have been widely recognized in the medical device market and research community, since the malfunctioning of IMDs might endanger the patient's life. During the last few years, a lot of researches have been carried out to address the security-related issues of IMDs, including privacy, safety, and accessibility issues. A physician accesses IMD through an external device called a programmer, for diagnosis and treatment. Hence, cryptographic key management between IMD and programmer is important to enforce a strict access control. In this paper, a new security architecture for the security of IMDs is proposed, based on a 3-Tier security model, where the programmer interacts with a Hospital Authentication Server, to get permissions to access IMDs. The proposed security architecture greatly simplifies the key management between IMDs and programmers. Also proposed is a security mechanism to guarantee the authenticity of the patient data collected from IMD and the nonrepudiation of the physician's treatment based on it. The proposed architecture and mechanism are analyzed and compared with several previous works, in terms of security and performance.

  9. Use of technical skills and medical devices among new registered nurses: A questionnaire study.

    Science.gov (United States)

    Ewertsson, Mona; Gustafsson, Margareta; Blomberg, Karin; Holmström, Inger K; Allvin, Renée

    2015-12-01

    One comprehensive part of nursing practice is performing technical skills and handling of medical equipment. This might be challenging for new registered nurses (RNs) to do in patient-safe way. The aim of this study was to describe and compare the extent to which new RNs perform various technical skills and handle medical devices in different settings, and to investigate their possibility for continued learning in this respect. A further aim was to describe their perceptions of incident reporting related to technical skills and medical devices. A cross-sectional study with descriptive and comparative design. RNs who recently graduated from a nursing programme at three Swedish universities and had worked as a RN for up to 1 year were included in the study (n=113, response rate 57%). Data were collected by means of a postal questionnaire. Half of the RNs reported that they performed several of the listed tasks every day or every week, regardless of workplace. These tasks were most frequently performed in surgical departments. The majority of the participants (76%) stated a need of continued practical training. However, less than half of them (48%) had access to a training environment. Several participants (43%) had been involved in incidents related to technical skills or medical devices, which were not always reported. Nearly a third of the participants (31%) did not use the existing guidelines when performing technical skills, and reflection on performance was uncommon. This study highlights the importance of shared responsibilities between nurse educators and health care employers to provide learning opportunities for new RNs in technical skills, to maintain patient safety. To increase the safety culture where nursing students and new RNs understand the importance of using evidence-based guidelines and taking a reflective approach in the performance of technical tasks is needed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Rapid and Low-cost Prototyping of Medical Devices Using 3D Printed Molds for Liquid Injection Molding

    Science.gov (United States)

    Chung, Philip; Heller, J. Alex; Etemadi, Mozziyar; Ottoson, Paige E.; Liu, Jonathan A.; Rand, Larry; Roy, Shuvo

    2014-01-01

    Biologically inert elastomers such as silicone are favorable materials for medical device fabrication, but forming and curing these elastomers using traditional liquid injection molding processes can be an expensive process due to tooling and equipment costs. As a result, it has traditionally been impractical to use liquid injection molding for low-cost, rapid prototyping applications. We have devised a method for rapid and low-cost production of liquid elastomer injection molded devices that utilizes fused deposition modeling 3D printers for mold design and a modified desiccator as an injection system. Low costs and rapid turnaround time in this technique lower the barrier to iteratively designing and prototyping complex elastomer devices. Furthermore, CAD models developed in this process can be later adapted for metal mold tooling design, enabling an easy transition to a traditional injection molding process. We have used this technique to manufacture intravaginal probes involving complex geometries, as well as overmolding over metal parts, using tools commonly available within an academic research laboratory. However, this technique can be easily adapted to create liquid injection molded devices for many other applications. PMID:24998993

  11. Incorporation of stochastic engineering models as prior information in Bayesian medical device trials.

    Science.gov (United States)

    Haddad, Tarek; Himes, Adam; Thompson, Laura; Irony, Telba; Nair, Rajesh

    2017-01-01

    Evaluation of medical devices via clinical trial is often a necessary step in the process of bringing a new product to market. In recent years, device manufacturers are increasingly using stochastic engineering models during the product development process. These models have the capability to simulate virtual patient outcomes. This article presents a novel method based on the power prior for augmenting a clinical trial using virtual patient data. To properly inform clinical evaluation, the virtual patient model must simulate the clinical outcome of interest, incorporating patient variability, as well as the uncertainty in the engineering model and in its input parameters. The number of virtual patients is controlled by a discount function which uses the similarity between modeled and observed data. This method is illustrated by a case study of cardiac lead fracture. Different discount functions are used to cover a wide range of scenarios in which the type I error rates and power vary for the same number of enrolled patients. Incorporation of engineering models as prior knowledge in a Bayesian clinical trial design can provide benefits of decreased sample size and trial length while still controlling type I error rate and power.

  12. Health professionals as mobile content creators: teaching medical students to develop mHealth applications.

    Science.gov (United States)

    Masters, Ken

    2014-10-01

    Patient access to health information and patient-provider communication is integral to medicine, and can be facilitated by mobile applications ("apps"). Traditionally, student training in mobile Health (mHealth) has focussed on health professionals as consumers of information, with negative impacts on the quality and value of medical apps. This study focuses on teaching medical students to develop their own medical apps. At Sultan Qaboos University, Oman, an app development environment, iBuildApp, was taught to medical students and used to develop their first apps. Students were surveyed on their perceptions of the project. Of the 166 students, 107 (64.5%) completed the survey. There was an increase in the perceived need for such learning, apps were aimed primarily at patients, and previous programming experience was the strongest influencer of a positive experience. A majority (77.6%) wanted more sophisticated development environments in spite of their apparent struggles. The impact of previous experience is similar to other studies; the perceived value and focus on patient apps is indicative of an awareness of patients' use of the devices not reflected in all literature. It is possible to teach medical students the fundamentals of app design so that they may contribute to app development in the future.

  13. Patient perceptions regarding the use of smart devices for medical photography: results of a patient-based survey.

    Science.gov (United States)

    Nair, Akshay Gopinathan; Potdar, Nayana A; Dadia, Suchit; Aulakh, Simranjeet; Ali, Mohammad Javed; Shinde, Chhaya A

    2018-03-06

    To assess patient perceptions regarding medical photography and the use of smart devices, namely mobile phones and tablets for medical photography. A questionnaire-based survey was conducted among 280 consecutive adult patients who presented to the oculoplastics clinic at a tertiary eye care centre. The responses were tabulated and analysed. Of the 280 patients surveyed, 68% felt that medical photography had a positive impact on their understanding of their illnesses and 72% felt that the use of smartphones for medical photography was acceptable. Respondents below the age of 40 years were more likely to approve of the use of mobile phones for photography as compared to those over 40. Most patients (74%) preferred a doctor to be the person photographing them. While a majority approved of doctors and trainee physicians having access to their photographs, they felt non-physician healthcare personnel should not have access to clinical photographs. Also, 72% of the respondents felt that the patient's consent should be taken before using their photographs. It was noted that patient identification and breach of confidentiality could be some of the potential issues with using smart devices as cameras in the clinic. Clinical photography in general and, specifically, using smart devices for clinical photographs have gained acceptance among patients. The outcomes of this study may be utilized to create policy guidelines for the use of smart devices as photography tools in the clinics. The findings of this survey can also help to create standardized, uniform patient consent forms for clinical photography.

  14. 75 FR 51829 - Public Workshop on Medical Devices and Nanotechnology: Manufacturing, Characterization, and...

    Science.gov (United States)

    2010-08-23

    ... hotel at 301-977-8900 or refer to their Web page at: www.gaithersburg.hilton.com . Contact Person: Daya... provide public comments, time permitting. If you need special accommodations due to a disability, please... refer to the meeting registration Web page at http://www.fda.gov/MedicalDevices/NewsEvents/Workshops...

  15. Health economic evaluations of medical devices in the People's Republic of China: A systematic literature review.

    Science.gov (United States)

    Zhang, Rongrong; Modaresi, Farhang; Borisenko, Oleg

    2015-01-01

    The objective of this study is to identify and review the methodological quality of health economic evaluations of medical devices performed in the People's Republic of China. To our knowledge, no such investigations have been performed to date. A systematic literature review involving searches of Medline, Medline In-Process, the National Health Service Economic Evaluation Database, the Cost-Effectiveness Analysis Registry of the Tufts Medical Center, and the Wanfang Database was performed. The search spanned the period from 1990 to 2013. Studies on health economic evaluations of medical devices, in-vitro diagnostics, procedures, and the use of medical devices in Chinese health care settings were included. Full-text articles and conference abstracts in English and Chinese were included. Fifty-seven publications were included, 26 (46%) of which were in English and 31 (54%) of which were in Chinese. The included publications covered a wide range of clinical areas, such as surgery (n=23, 40%), screening (n=9, 16%), imaging use (n=6, 11%), kidney intervention (n=4, 7%), and nine other technological areas. Most of the studies (n=31, 54%) were cost analyses. Among the others, 13 (50%) studies used modeling, and another 13 (50%) were within-trial evaluations. Among studies that used modeling, eleven (85%) conducted sensitivity analyses, six of which had one-way sensitivity analysis, whereas one conducted both one-way and two-way sensitivity analyses; four of these eleven modeling-based analyses included probabilistic sensitivity analyses. The incremental cost-effectiveness ratio was reported in ten (18%) studies, eight of which were screening studies. The remaining two modeling studies were in areas of imaging and oncology. This study indicates that there are major limitations and deficiencies in the health economic evaluations on medical devices performed in the People's Republic of China. Further efforts are required from different stakeholders - academic, governmental

  16. Technologies for Medical Sciences

    CERN Document Server

    Tavares, João; Barbosa, Marcos; Slade, AP

    2012-01-01

    This book presents novel and advanced technologies for medical sciences in order to solidify knowledge in the related fields and define their key stakeholders.   The fifteen papers included in this book were written by invited experts of international stature and address important technologies for medical sciences, including: computational modeling and simulation, image processing and analysis, medical imaging, human motion and posture, tissue engineering, design and development medical devices, and mechanic biology. Different applications are treated in such diverse fields as biomechanical studies, prosthesis and orthosis, medical diagnosis, sport, and virtual reality.   This book is of interest to researchers, students and manufacturers from  a wide range of disciplines related to bioengineering, biomechanics, computational mechanics, computational vision, human motion, mathematics, medical devices, medical image, medicine and physics.

  17. Pricing of medical devices under coverage uncertainty--a modelling approach.

    Science.gov (United States)

    Girling, Alan J; Lilford, Richard J; Young, Terry P

    2012-12-01

    Product vendors and manufacturers are increasingly aware that purchasers of health care will fund new clinical treatments only if they are perceived to deliver value-for-money. This influences companies' internal commercial decisions, including the price they set for their products. Other things being equal, there is a price threshold, which is the maximum price at which the device will be funded and which, if its value were known, would play a central role in price determination. This paper examines the problem of pricing a medical device from the vendor's point of view in the presence of uncertainty about what the price threshold will be. A formal solution is obtained by maximising the expected value of the net revenue function, assuming a Bayesian prior distribution for the price threshold. A least admissible price is identified. The model can also be used as a tool for analysing proposed pricing policies when no formal prior specification of uncertainty is available. Copyright © 2011 John Wiley & Sons, Ltd.

  18. Effects of sterilization on the mechanical properties of poly(methyl methacrylate) based personalized medical devices.

    Science.gov (United States)

    Münker, T J A G; van de Vijfeijken, S E C M; Mulder, C S; Vespasiano, V; Becking, A G; Kleverlaan, C J; Becking, A G; Dubois, L; Karssemakers, L H E; Milstein, D M J; van de Vijfeijken, S E C M; Depauw, P R A M; Hoefnagels, F W A; Vandertop, W P; Kleverlaan, C J; Münker, T J A G; Maal, T J J; Nout, E; Riool, M; Zaat, S A J

    2018-05-01

    Nowadays, personalized medical devices are frequently used for patients. Due to the manufacturing procedure sterilization is required. How different sterilization methods affect the mechanical behavior of these devices is largely unknown. Three poly(methyl methacrylate) (PMMA) based materials (Vertex Self-Curing, Palacos R+G, and NextDent C&B MFH) were sterilized with different sterilization methods: ethylene oxide, hydrogen peroxide gas plasma, autoclavation, and γ-irradiation. Mechanical properties were determined by testing the flexural strength, flexural modulus, fracture toughness, and impact strength. The flexural strength of all materials was significantly higher after γ-irradiation compared to the control and other sterilization methods, as tested in a wet environment. NextDent C&B MFH showed the highest flexural and impact strength, Palacos R+G showed the highest maximum stress intensity factor and total fracture work. Autoclave sterilization is not suitable for the sterilization of PMMA-based materials. Ethylene oxide, hydrogen peroxide gas plasma, and γ-irradiation appear to be suitable techniques to sterilize PMMA-based personalized medical devices. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. Differential effects of public and private funding in the medical device industry.

    Science.gov (United States)

    Kang, Hyunsung D; Ku, David N

    2018-02-01

    Funding for scientific advancement comes from two dominant sources: public funds used to generate knowledge, and private sector funds in the pursuit of commercial products. It is unclear how to compare the outputs of these two financial mechanisms because both sectors are motivated by common goods but are also governed by divergent forces. Employment within a geographic region may be a metric of mutual value that can be applied equally to assess the societal impacts of two financing sources. Areas covered: The authors focused on the medical device industry, which is a robust sector of growth for the U.S. economy. The U.S. NIH and venture capital community are representatives of public and private capital, respectively. Using a longitudinal employment dataset of 247 distinct locations, the authors found that NIH funding tends to create more jobs directly compared to venture capital funding. Moreover, the indirect effect of governmental funding is initially smaller than that of venture capital funding for the first two years, but eventually surpasses that of venture capital funding. Expert commentary: These findings imply that policy decisions regarding financial allocations in the medical device industry should consider the appropriate typology of financial capital and its consequences.

  20. Linking the Regulatory and Reimbursement Processes for Medical Devices : The Need for Integrated Assessments

    NARCIS (Netherlands)

    Ciani, Oriana; Wilcher, Britni; van Giessen, Anoukh; Taylor, Rod S.

    2017-01-01

    Much criticism has been directed at the licencing requirements for medical devices (MDs) as they often result in a lack of robust evidence to inform health technology assessment (HTA) decisions. To better understand the current international decisional framework on MD technologies, we undertook

  1. Which medical device and/or which local treatment for prevention in patients with risk factors for pressure sores in 2012? Developing French guidelines for clinical practice.

    Science.gov (United States)

    Nicolas, B; Moiziard, A S; Barrois, B; Colin, D; Michel, J M; Passadori, Y; Ribinik, P

    2012-10-01

    Implementation of a prevention strategy after the identification of risk factors is essential at the entrance in a care unit or in a medical-social unit. Determine which medical devices and which treatments may be used in order to prevent pressure sore in 2012. Systematic review of the literature using databases: Pascal, Biomed, PubMed, and Cochrane library between 2000 and 2010. Nursing care including use of soft product, non-irritating for the cleaning, hydration of the skin with emollients, protection of fragile skin in case of incontinence by applying a skin protector and application of dressings in front of bony prominences to reduce shear forces, remain valid (level C). Nursing cares and use of dressing in patients with high risks of pressure sores are the responsibility of the nurses. The engagement of health care teams involves screening of risk factors and the knowledge of treatments and local devices. Local preventive treatment in a patient with risk factors of pressure sore is of great interest at entrance in a care unit or in a medical-social unit. Copyright © 2012. Published by Elsevier Masson SAS.

  2. Surgical virtual reality - highlights in developing a high performance surgical haptic device.

    Science.gov (United States)

    Custură-Crăciun, D; Cochior, D; Constantinoiu, S; Neagu, C

    2013-01-01

    Just like simulators are a standard in aviation and aerospace sciences, we expect for surgical simulators to soon become a standard in medical applications. These will correctly instruct future doctors in surgical techniques without there being a need for hands on patient instruction. Using virtual reality by digitally transposing surgical procedures changes surgery in are volutionary manner by offering possibilities for implementing new, much more efficient, learning methods, by allowing the practice of new surgical techniques and by improving surgeon abilities and skills. Perfecting haptic devices has opened the door to a series of opportunities in the fields of research,industry, nuclear science and medicine. Concepts purely theoretical at first, such as telerobotics, telepresence or telerepresentation,have become a practical reality as calculus techniques, telecommunications and haptic devices evolved,virtual reality taking a new leap. In the field of surgery barrier sand controversies still remain, regarding implementation and generalization of surgical virtual simulators. These obstacles remain connected to the high costs of this yet fully sufficiently developed technology, especially in the domain of haptic devices. Celsius.

  3. Implantable photonic devices for improved medical treatments

    Science.gov (United States)

    Sheinman, Victor; Rudnitsky, Arkady; Toichuev, Rakhmanbek; Eshiev, Abdyrakhman; Abdullaeva, Svetlana; Egemkulov, Talantbek; Zalevsky, Zeev

    2014-10-01

    An evolving area of biomedical research is related to the creation of implantable units that provide various possibilities for imaging, measurement, and the monitoring of a wide range of diseases and intrabody phototherapy. The units can be autonomic or built-in in some kind of clinically applicable implants. Because of specific working conditions in the live body, such implants must have a number of features requiring further development. This topic can cause wide interest among developers of optical, mechanical, and electronic solutions in biomedicine. We introduce preliminary clinical trials obtained with an implantable pill and devices that we have developed. The pill and devices are capable of applying in-body phototherapy, low-level laser therapy, blue light (450 nm) for sterilization, and controlled injection of chemicals. The pill is also capable of communicating with an external control box, including the transmission of images from inside the patient's body. In this work, our pill was utilized for illumination of the sinus-carotid zone in dog and red light influence on arterial pressure and heart rate was demonstrated. Intrabody liver tissue laser ablation and nanoparticle-assisted laser ablation was investigated. Sterilization effect of intrabody blue light illumination was applied during a maxillofacial phlegmon treatment.

  4. FDA publishes checklist of Y2K high-risk devices.

    Science.gov (United States)

    1999-09-01

    Key points. The federal Food and Drug Administration (FDA) has developed a list of types of medical devices that have the potential for the most serious consequences for patients should they fail because of Y2K-related problems. This list of computer-controlled potentially high-risk devices can provide a guide to health care facilities regarding the types of devices that should receive priority in their assessment and remediation of medical devices. The list may change as the FDA receives comments on the types of devices included in the list.

  5. Review of "Handbook of Human Factors in Medical Device Design", edited by Matthew B. Weinger, Michael E. Wiklund and Daryle J. Gardner-Bonneau, Assistant Editor Loir M. Kelly

    Directory of Open Access Journals (Sweden)

    Gaev Jonathan A

    2011-06-01

    Full Text Available Abstract Human factors is the study of the relationship between people and devices or systems. The goal of considering human factors in the design of medical devices is to create devices that take into consideration the way people use technology and process information to create a man-machine interface that leads to the best possible performance. This text describes the significant aspects of human factors issues related to medical device design. It is well written and is useful for medical device designers and for others who use or evaluate medical equipment.

  6. 77 FR 60704 - Medical Devices; Availability of Safety and Effectiveness Summaries for Premarket Approval...

    Science.gov (United States)

    2012-10-04

    ... regulations provide that FDA publish a quarterly list of available safety and effectiveness summaries of PMA...-0638] Medical Devices; Availability of Safety and Effectiveness Summaries for Premarket Approval... Administration (FDA) is publishing a list of premarket approval applications (PMAs) that have been approved. This...

  7. Development and validation of a noncontact spectroscopic device for hemoglobin estimation at point-of-care

    Science.gov (United States)

    Sarkar, Probir Kumar; Pal, Sanchari; Polley, Nabarun; Aich, Rajarshi; Adhikari, Aniruddha; Halder, Animesh; Chakrabarti, Subhananda; Chakrabarti, Prantar; Pal, Samir Kumar

    2017-05-01

    Anemia severely and adversely affects human health and socioeconomic development. Measuring hemoglobin with the minimal involvement of human and financial resources has always been challenging. We describe a translational spectroscopic technique for noncontact hemoglobin measurement at low-resource point-of-care settings in human subjects, independent of their skin color, age, and sex, by measuring the optical spectrum of the blood flowing in the vascular bed of the bulbar conjunctiva. We developed software on the LabVIEW platform for automatic data acquisition and interpretation by nonexperts. The device is calibrated by comparing the differential absorbance of light of wavelength 576 and 600 nm with the clinical hemoglobin level of the subject. Our proposed method is consistent with the results obtained using the current gold standard, the automated hematology analyzer. The proposed noncontact optical device for hemoglobin estimation is highly efficient, inexpensive, feasible, and extremely useful in low-resource point-of-care settings. The device output correlates with the different degrees of anemia with absolute and trending accuracy similar to those of widely used invasive methods. Moreover, the device can instantaneously transmit the generated report to a medical expert through e-mail, text messaging, or mobile apps.

  8. 76 FR 50230 - Center for Devices and Radiological Health 510(k) Clearance Process; Recommendations Proposed in...

    Science.gov (United States)

    2011-08-12

    ... develop and implement a program of continuous quality improvement to track regulatory decisions on medical devices, identify potential process improvements in the medical device regulatory framework, and address... software used in devices, software used as devices, and software used as a tool in producing devices. 8...

  9. Three-Dimensional Printed PCL-Based Implantable Prototypes of Medical Devices for Controlled Drug Delivery

    DEFF Research Database (Denmark)

    Hollander, Jenny; Genina, Natalja; Jukarainen, Harri

    2016-01-01

    The goal of the present study was to fabricate drug-containing T-shaped prototypes of intrauterine system (IUS) with the drug incorporated within the entire backbone of the medical device using 3-dimensional (3D) printing technique, based on fused deposition modeling (FDM™). Indomethacin was used...... prototypes were dependent on the amount of drug loading. The drug release profiles from the printed devices were faster than from the corresponding filaments due to a lower degree of the drug crystallinity in IUS in addition to the differences in the external/internal structure and geometry between...

  10. 77 FR 125 - Draft Guidance for Industry and Food and Drug Administration Staff; Medical Device Classification...

    Science.gov (United States)

    2012-01-03

    ... organization. These 16 Panels have largely been the driving force for CDRH's internal organizational structure...). The draft guidance, when finalized, will represent the Agency's current thinking on medical device...

  11. A color display device recording X ray spectra, especially intended for medical radiography

    International Nuclear Information System (INIS)

    Boulch, J.-M.

    1975-01-01

    Said invention relates to a color display recording device for X ray spectra intended for medical radiography. The video signal of the X ray camera receiving the radiation having passed through the patient is amplified and transformed into a color coding according to the energy spectrum received by the camera. In a first version, the energy spectrum from the camera gives directly an image on the color tube. In a second version the energy spectrum, after having been transformed into digital signals, is first sent into a memory, then into a computer used as a spectrum analyzer, and finally into the color display device [fr

  12. To recognize the use of international standards for making harmonized regulation of medical devices in Asia-pacific.

    Science.gov (United States)

    Anand, K; Saini, Ks; Chopra, Y; Binod, Sk

    2010-07-01

    'Medical Devices' include everything from highly sophisticated, computerized, medical equipment, right down to simple wooden tongue depressors. Regulations embody the public expectations for how buildings and facilities are expected to perform and as such represent public policy. Regulators, who develop and enforce regulations, are empowered to act in the public's interest to set this policy and are ultimately responsible to the public in this regard. Standardization contributes to the basic infrastructure that underpins society including health and environment, while promoting sustainability and good regulatory practice. The international organizations that produce International Standards are the International Electrotechnical Commission (IEC), the International Organization for Standardization (ISO), and the International Telecommunication Union (ITU). With the increasing globalization of markets, International Standards (as opposed to regional or national standards) have become critical to the trading process, ensuring a level playing field for exports, and ensuring that imports meet the internationally recognized levels of performance and safety. The development of standards is done in response to sectors and stakeholders that express a clearly established need for them. An industry sector or other stakeholder group typically communicates its requirement for standards to one of the national members. To be accepted for development, a proposed work item must receive a majority support of the participating members, who verify the global relevance of the proposed item. The regulatory authority (RA) should provide a method for the recognition of international voluntary standards and for public notification of such recognition. The process of recognition may vary from country to country. Recognition may occur by periodic publication of lists of standards that a regulatory authority has found will meet the Essential Principles. In conclusion, International standards

  13. 78 FR 17415 - Medical Devices; Availability of Safety and Effectiveness Summaries for Premarket Approval...

    Science.gov (United States)

    2013-03-21

    ... its decision. The regulations provide that FDA publish a quarterly list of available safety and..., FDA-2012-M-1183, and FDA-2012-M-1184] Medical Devices; Availability of Safety and Effectiveness.... SUMMARY: The Food and Drug Administration (FDA) is publishing a list of premarket approval applications...

  14. Security Mechanism Based on Hospital Authentication Server for Secure Application of Implantable Medical Devices

    Directory of Open Access Journals (Sweden)

    Chang-Seop Park

    2014-01-01

    Full Text Available After two recent security attacks against implantable medical devices (IMDs have been reported, the privacy and security risks of IMDs have been widely recognized in the medical device market and research community, since the malfunctioning of IMDs might endanger the patient’s life. During the last few years, a lot of researches have been carried out to address the security-related issues of IMDs, including privacy, safety, and accessibility issues. A physician accesses IMD through an external device called a programmer, for diagnosis and treatment. Hence, cryptographic key management between IMD and programmer is important to enforce a strict access control. In this paper, a new security architecture for the security of IMDs is proposed, based on a 3-Tier security model, where the programmer interacts with a Hospital Authentication Server, to get permissions to access IMDs. The proposed security architecture greatly simplifies the key management between IMDs and programmers. Also proposed is a security mechanism to guarantee the authenticity of the patient data collected from IMD and the nonrepudiation of the physician’s treatment based on it. The proposed architecture and mechanism are analyzed and compared with several previous works, in terms of security and performance.

  15. Results from an exploratory study to identify the factors that contribute to success for UK medical device small- and medium-sized enterprises.

    Science.gov (United States)

    Hourd, P C; Williams, D J

    2008-07-01

    This paper reports the results from an exploratory study that sets out to identify and compare the strategic approaches and patterns of business practice employed by 14 UK small- and medium-sized enterprises to achieve success in the medical device sector of the health-care industry. An interview-based survey was used to construct individual case studies of the medical device technology (MDT) companies. A cross-case analysis was performed to search for patterns and themes that cut across these individual cases. Exploratory results revealed the heterogeneity of MDT companies and the distinctive features of the MDT innovation process that emphasize the importance of a strategic approach for achieving milestones in the product development and exploitation process and for creating value for the company and its stakeholders. Recognizing the heterogeneity of MDT companies, these exploratory findings call for further investigation to understand better the influence of components of the MDT innovation process on the commercialization life cycle and value trajectory. This is required to assist start-up or spin-out MDT companies in the UK and worldwide to navigate the critical transitions that determine access to financial and consumer markets and enhance the potential to build a successful business. This will be important not only for bioscience-based companies but also for engineering-based companies aiming to convert their activities into medical devices and the health- and social-care market.

  16. Electromedical devices test laboratories accreditation

    International Nuclear Information System (INIS)

    Murad, C; Rubio, D; Ponce, S; Alvarez Abri, A; Terron, A; Vicencio, D; Fascioli, E

    2007-01-01

    In the last years, the technology and equipment at hospitals have been increase in a great way as the risks of their implementation. Safety in medical equipment must be considered an important issue to protect patients and their users. For this reason, test and calibrations laboratories must verify the correct performance of this kind of devices under national and international standards. Is an essential mission for laboratories to develop their measurement activities taking into account a quality management system. In this article, we intend to transmit our experience working to achieve an accredited Test Laboratories for medical devices in National technological University

  17. Establishment Of Dose Correlation During Dose Mapping On Medical Devices

    International Nuclear Information System (INIS)

    Ruzalina Baharin; Hasan Sham; Ahsanulkhaliqin Abdul Wahab

    2014-01-01

    This paper explains the work done during product dose mapping in order to get the correlation between doses at MINTec-Sinagama plant. Product used was medical devices in aluminium tubes packaged in cardboard kegs packaging with average weight of 12 kg per carton. 12 cartons were loaded in every one tote to give 0.2 g/ cm 3 of density. Ceric cerous dosimeters were placed at specific locations as indicated in SP14: Product Dose Mapping, QMS of MINTec-Sinagama around three planes. Three processes were made at different days as a three replicates to show the reproducibility of measurements. (author)

  18. Personal medical electronic devices and walk-through metal detector security systems: assessing electromagnetic interference effects.

    Science.gov (United States)

    Guag, Joshua; Addissie, Bisrat; Witters, Donald

    2017-03-20

    There have been concerns that Electromagnetic security systems such as walk-through metal detectors (WTMDs) can potentially cause electromagnetic interference (EMI) in certain active medical devices including implantable cardiac pacemakers and implantable neurostimulators. Incidents of EMI between WTMDs and active medical devices also known as personal medical electronic devices (PMED) continue to be reported. This paper reports on emission measurements of sample WTMDs and testing of 20 PMEDs in a WTMD simulation system. Magnetic fields from sample WTMD systems were characterized for emissions and exposure of certain PMEDs. A WTMD simulator system designed and evaluated by FDA in previous studies was used to mimic the PMED exposures to the waveform from sample WTMDs. The simulation system allows for controlled PMED exposure enabling careful study with adjustable magnetic field strengths and exposure duration, and provides flexibility for PMED exposure at elevated levels in order to study EMI effects on the PMED. The PMED samples consisted of six implantable cardiac pacemakers, six implantable cardioverter defibrillators (ICD), five implantable neurostimulators, and three insulin pumps. Each PMED was exposed in the simulator to the sample WTMD waveforms using methods based on appropriate consensus test standards for each of the device type. Testing the sample PMEDs using the WTMD simulator revealed EMI effects on two implantable pacemakers and one implantable neurostimulator for exposure field strength comparable to actual WTMD field strength. The observed effects were transient and the PMEDs returned to pre-exposure operation within a few seconds after removal from the simulated WTMD exposure fields. No EMI was observed for the sample ICDs or insulin pumps. The findings are consistent with earlier studies where certain sample PMEDs exhibited EMI effects. Clinical implications were not addressed in this study. Additional studies are needed to evaluate potential PMED

  19. Developing and Assessing Curriculum on the Physics of Medical Instruments

    Science.gov (United States)

    Christensen, Warren; Johnson, James K.; Van Ness, Grace R.; Mylott, Elliot; Dunlap, Justin C.; Anderson, Elizabeth A.; Widenhorn, Ralf

    2013-01-01

    Undergraduate educational settings often struggle to provide students with authentic biologically or medically relevant situations and problems that simultaneously improve their understanding of physics. Through exercises and laboratory activities developed in an elective Physics in Biomedicine course for upper-level biology or pre–health majors at Portland State University, we aim to teach fundamental physical concepts, such as light absorption and emission and atomic energy levels, through analysis of biological systems and medical devices. The activities address the properties of electromagnetic waves as they relate to the interaction with biological tissue and make links between physics and biomedical applications such as microscopy or laser eye surgery. We report on the effect that engaging students in tasks with actual medical equipment has had on their conceptual understanding of light and spectroscopy. These initial assessments indicate that students’ understanding improves in some areas as a result of taking the course, but gains are not uniform and are relatively low for other topics. We also find a promising “nonshift” in student attitudes toward learning science as a result of taking the course. A long-term goal of this work is to develop these materials to the extent that they can eventually be imported into an introductory curriculum for life sciences majors. PMID:23737632

  20. System theory in medical diagnostic devices: an overview.

    Science.gov (United States)

    Baura, Gail D

    2006-01-01

    Medical diagnostics refers to testing conducted either in vitro or in vivo to provide critical health care information for risk assessment, early diagnosis, treatment, or disease management. Typical in vivo diagnostic tests include the computed tomography scan, magnetic resonance imaging, and blood pressure screening. Typical in vitro diagnostic tests include cholesterol, Papanicolaou smear, and conventional glucose monitoring tests. Historically, devices associated with both types of diagnostics have used heuristic curve fitting during signal analysis. However, since the early 1990s, a few enterprising engineers and physicians have used system theory to improve their core processing for feature detection and system identification. Current applications include automated Pap smear screening for detection of cervical cancer and diagnosis of Alzheimer's disease. Future applications, such as disease prediction before symptom onset and drug treatment customization, have been catalyzed by the Human Genome Project.